Semiconductor laser applications in rheumatology
NASA Astrophysics Data System (ADS)
Pascu, Mihail-Lucian; Suteanu, S.
1996-01-01
Two types of laser diode (LD) based equipment for rheumatology are introduced. The first is a portable device which contains single LD emitting at 890 nm laser pulses (time full width 100 nsec) of reprate tunable within (0.5 - 1.5) kHz; the laser beam average power is 0.7 mW at 1 kHz reprate. The second is computer controlled, contains one HeNe laser and 5 LD allowing 6 modes of patient irradiation (placebo effect evaluation included). HeNe laser works in cw at 632.8 nm; the LD works each as described for the portable equipment. HeNe and LD beams are superposed so that HeNe laser spot in the irradiation plane has a 60 mm diameter and the LD spots covers a 50 mm diameter disc centered on the HeNe laser spot. Clinical applications using the second type of equipment are reported; 1287 patients were treated between October 1991 and October 1994. Female/male ratio was 4:1 and their age distribution was between 18 and 85 years. The average number of exposures was 10 and the mean exposure time was 7 minutes. Studies were made on the treatment of rheumatoid arthritis, seronegative arthritis, degenerative joint diseases, abarticular rheumatism, osteoporosis pain and pains and edema after fractures.
Pöntinen, P J; Aaltokallio, T; Kolari, P J
1996-01-01
This study assessed the effects of optic stimuli emitted by three different light sources on head skin blood flow. The irradiation effects of the He-Ne laser (632.8 nm, 10 mW, total energy appr. 9.4 J), the InGaAl diode laser (670 nm, 60 mW, appr. 108 J) and monochromatic light (635 nm, 112.5 mW, appr. 202.5 J) were measured using laser Doppler technology. The corresponding fluences (energy densities) varied from 0.01 J/cm2 (He-Ne) to a range of 0.12-0.72 J/cm2 (InGaAl) and 0.22-1.36 J/cm2 (LED). The investigation was completed under single-blind, placebo-controlled conditions where the subjects (10 male healthy volunteers) were exposed on two occasions to the placebo (LED)-device against the laser (He-Ne or InGaAl). A short lasting vasodilation, a 54 per cent increase (p < 0.05) in skin blood flow was seen after the InGaAl irradiation (fluences between 0.12-0.36 J/cm2) whereas the non-coherent monochromatic irradiation (0.68-1.36 J/cm2) used in this particular study decreased blood flow by 36 per cent (p < 0.05). The He-Ne irradiation (0.01 J/cm2) had no effect. Skin temperature changes were insignificant. Skin blood flow changes seemed to be related more on radiant exposures then coherency.
Gao, Limei; Li, Yongfeng; Shen, Zhihua; Han, Rong
2018-05-01
UV-B acclimation effects and UV-B damage repair induced by a 632.8-nm He-Ne laser were investigated in Arabidopsis thaliana plants in response to supplementary UV-B stress. There was an increasing trend in growth parameters in the combination-treated plants with He-Ne laser and UV-B light compared to those stressed with enhanced UV-B light alone during different developmental stages of plants. The photosynthetic efficiency (Pn) and survival rates of seedlings were significantly higher in the combination treatments than UV-B stress alone. The expression of UVR8, phytochrome B (PhyB), and their mediated signal responsive genes such as COP1, HY5, and CHS were also significantly upregulated in plants with the laser irradiation compared with other groups without the laser. Levels of flavonol accumulation in leaves and capsule yield of He-Ne laser-treated plants were increased. The phyB-9 mutants were more sensitive to enhanced UV-B stress and had no obvious improvements in plant phenotypic development and physiological damage caused by enhanced UV-B stress after He-Ne laser irradiation. Our results suggested that UVR8 and its mediated signaling pathway via interaction with COP1 can be induced by He-Ne laser, and these processes were dependent on cytoplasmic PhyB levels in plant cells, which might be one of the most important mechanisms of He-Ne laser on UV-B protection and UV-B damage repair. These current data have also elucidated that the biostimulatory effects of He-Ne laser on Arabidopsis thaliana plants would happen not only during the early growth stage but also during the entire late developmental stage.
Measurements on the He-Ne laser lines near 633 nm
NASA Astrophysics Data System (ADS)
Steinhaus, David W.
1983-09-01
The red line from an inexpensive He-Ne laser is made up of several closely spaced lines. To separate these lines very high spectral resolution is required. This apparatus requirement can be met by a simple modification of a student Fabry-Perot interferometer. Laboratory measurements can then be made to verify the expected number, spacing, and polarization of these lines during a single afternoon laboratory session.
[Low-level laser therapy in osteoarticular diseases in geriatric patients].
Giavelli, S; Fava, G; Castronuovo, G; Spinoglio, L; Galanti, A
1998-04-01
Laser light absorption through the skin causes tissue changes, targeting the nervous, the lymphatic, the circulatory and the immune systems with an antalgic, anti-inflammatory, anti-edemic effect and stimulating tissue repair. Therefore low level laser therapy is now commonly used in numerous rehabilitation centers, including the "Istituto Gerontologico Pio Albergo Trivulzio", Milan, Italy. However, to activate the treatment program, the basic medical research results must always be considered to choose the best optical wavelength spectrum, technique and dose, for rehabilitative laser therapy. We analyzed the therapeutic effects of different wavelengths and powers in various treatment schedules. In particular, a protocol was designed to test such physical parameters as laser type, doses and individual schedule in different pathologic conditions. We report the results obtained with low level laser therapy in the rehabilitation of geriatric patients, considering the various physical and technical parameters used in our protocol. We used the following laser equipment: an HeNe laser with 632.8 nm wavelength (Mectronic), a GaAs Laser with 904 nm wavelength (Mectronic) and a CO2 Laser with 10,600 nm wavelength (Etoile). To evaluate the patient clinical status, we use a different form for each involved joint; the laser beam is targeted on the region of interest and irradiation is carried out with the sweeping method or the points technique. Irradiation technique, doses and physical parameters (laser type, wavelength, session dose and number) are indicated on the form. The complete treatment cycle consists of 5 sessions per week--20 sessions in all. At the end of the treatment cycle, the results were scored on a 5-grade semiquantitative scale--excellent, good, fair, poor and no results. We examined 3 groups of patients affected with gonarthrosis (149 patients), lumbar arthrosis (117 patients), and algodystrophy (140 patients) respectively. In gonarthrosis patients, the statistical analysis of the results showed no significant differences between CO2 laser and GaAs laser treatments (p = .975), but significant differences between CO2 laser and HeNe laser treatments (p = .02) and between GaAs laser and HeNe laser treatments (p = .003). In lumbar arthrosis patients treated with GaAs or HeNe laser, significant differences were found between the two laser treatments and the combined sweeping-points techniques appeared to have a positive trend relative to the sweeping method alone, especially in sciatic suffering. In the algodystrophy syndrome, in hemiplegic patients, significant differences were found between CO2 and HeNe laser treatments (p = .026), between high and low CO2 laser doses (p = .024), and between low CO2 laser dose and high HeNe laser dose (p = .006). Low level laser therapy can be used to treat osteoarticular pain in geriatric patients. To optimize the results, the diagnostic picture must be correct and a treatment program defining the physical parameters used (wavelength, dose and irradiation technique) must also be designed.
An All-Optical Picosecond Switch in Polydiacetylene
NASA Technical Reports Server (NTRS)
Abdeldayem, Hossin; Frazier, Donald O.; Paley, Mark S.
2002-01-01
Polydiacetylene derivative of 2-methyl-4-nitroaniline (PDAMNA) showed a picosecond switching property. This phenomenon was demonstrated by wave guiding a cw He-Ne laser collinearly with a mode-locked picosecond Nd:YAG laser at 532 nm through a hollow fiber coated on the inside with a thin film of PDAMNA. The z-scan investigations of PDAMNA thin film revealed that the PDAMNA system is a three level system and the switching is caused by excited state absorption of the He-Ne beam.
NASA Astrophysics Data System (ADS)
Zhao, Yanping; Liu, Song-hao; Sun, Jinbo; Luo, Gangyue; Hua, Rong; Liu, Qianqin
2005-01-01
The aim of this study was to test human erythrocyte deformability with the exposure of erythrocyte from apoplexy patient and other ischemia diseases, contracted with normal donors' blood sample, and the doses-effect of Low-power He_Ne laser in vitro were discussed. Fresh blood sample from adult health donors and patients with different diseases such as apoplexy, diabetes, heart block etc in emergency department were collected and divided into different groups in which there were no less than 6 persons. Fresh human blood samples were irradiated with a He-Ne laser (Lamba=632.8nm), power output around 4.5MW, 9MW, 15mW, and 18mW, et al., exposure time from 7.5min, 15min, and 30min, operating in continuous wave. Measurements of human erythrocyte deformability were taken. Erythrocyte deformability appearance shown some different in the health contracted group and the other ischemia disease group. Some notice difference also shown among some disease group with nonirradiation and the same disease group with laser irradiation. The dose-effects of He-Ne laser therapy was discussed on the further research on the erythrocyte deformability of blood sample from patients with apoplexy disease treated with He-Ne laser at different doses, and a certain optimal doses which could take a beneficial effect in clinic were speculated on. This study revealed that the He-Ne laser have some different effects on erythrocyte deformability in vitro, which were related with the disease condition, red cell state, and outpower-doses, et al closely.
NASA Astrophysics Data System (ADS)
Belski, Alexey I.; Chivanov, Vadym D.
1996-09-01
Spring barley, winter wheat and maize seeds were subjected to the action of He-Ne laser irradiation having a low intensity in the visible region of the spectrum (628-640 nm) in conjunction with magnetic fields. The following results were obtained: laser irradiation with magnetic fields induced activation of the natural plant defence/immune systems gave the harvest crop level increased to about 50- 300 percent; a correlation was established between the rate of the fungal pathogens growth and the stimulation of plant immunity after the seeds had been treated with laser irradiation and magnetic field.
Study of nonlinear refraction of organic dye by Z-scan technique using He-Ne laser
DOE Office of Scientific and Technical Information (OSTI.GOV)
Medhekar, S.; Kumar, R.; Mukherjee, S.
2013-02-05
Laser induced third-order nonlinear optical responses of Brilliant Green solution has been investigated by utilizing single beam Z-scan technique with a continuous-wave He-Ne laser radiation at 632.8 nm. It was observed that the material exhibits self-defocusing type optical nonlinearity. The measurements of nonlinear refraction were carried out at different dye concentrations and found that the increase in solution concentration leads to the linear increase of the nonlinear refractive index. The experimental results confirm great potential of the Brilliant Green for the application in nonlinear optical devices.
NASA Astrophysics Data System (ADS)
Dudareva, L. V.; Rudikovskaya, E. G.; Shmakov, V. N.; Rudikovskii, A. V.; Salyaev, R. K.
2017-05-01
We carried out an analysis of the influence of low-intensity He-Ne laser radiation on the dynamics of changes observed in the content of the phytohormones abscisic, jasmonic, salicylic, and indoleacetic acids in wheat calluses of Triticum aestivum L. using chromatography-mass spectrometry. He-Ne laser irradiation (λ = 632.8 nm) in its stimulant dose (3.5 J cm-2) was proved to cause a decrease in jasmonic and indoleacetic acid content and, simultaneously, a significant (2.5-3 times) increase in ‘stress’ abscisic and salicylic acids. The response of jasmonic acid to He-Cd laser irradiation (λ = 441 nm) was specific, which is probably due to the blue-light-induced biosynthesis of the acid. This article discusses a possible connection between substantial changes in growth regulator content within the plant tissue under the influence of low-intensity laser irradiation and the stress character of this type of radiation.
Effect of low power laser irradiation on macrophage phagocytic capacity
NASA Astrophysics Data System (ADS)
Lu, Cuixia; Song, Sheng; Tang, Yu; Zhou, Feifan
2011-03-01
Phagocytosis and subsequent degradation of pathogens by macrophages play a pivotal role in host innate immunity in mammals. Laser irradiation has been found to produce photobiological effects with evidence of interference with immunological functions. However, the effects of laser on the immune response have not been extensively characterized. In this study, we focused our attention on the effects of He-Ne laser on the phagocytic activity of macrophages by using flow cytometry (FCM). After irradiating at fluence of 0, 1, 2 J/cm2 with He-Ne laser (632.8 nm, 3mw), the cells were incubated with microsphere and then subjected to FACS analysis. The results showed that Low-power laser irradiation (LPLI) leads to an increase in phagocytosis on both mouse peritoneal macrophages and the murine macrophage-like cell line RAW264.7. In addition, we demonstrated that LPLI increased phagocytosis of microsphere in a dose-dependent manner, reaching a maximum at fluence of 2 J/cm2. Taken together, our results indicated that Low-power laser irradiation with appropriate dosage can enhance the phagocytosis of macrophage, and provided a theoretical base for the clinical use of the He-Ne laser.
NASA Astrophysics Data System (ADS)
Zhang, Xiaoman; Yu, Biying; Weng, Cuncheng; Li, Hui
2014-11-01
The 632nm wavelength low intensity He-Ne laser was used to irradiated on 15 mice which had skin wound. The dynamic changes and wound healing processes were observed with nonlinear spectral imaging technology. We observed that:(1)The wound healing process was accelerated by the low-level laser therapy(LLLT);(2)The new tissues produced second harmonic generation (SHG) signals. Collagen content and microstructure differed dramatically at different time pointed along the wound healing. Our observation shows that the low intensity He-Ne laser irradiation can accelerate the healing process of skin wound in mice, and SHG imaging technique can be used to observe wound healing process, which is useful for quantitative characterization of wound status during wound healing process.
NASA Astrophysics Data System (ADS)
Cohen, Natalie; Lubart, Rachel; Rubinstein, Sara; Breitbart, Haim
1996-11-01
630 nm He-Ne laser irradiation was found to have a profound influence on Ca2+ uptake in mouse spermatozoa and the fertilizing potential of these cells. Laser irradiation affected mainly the mitochondrial Ca2+ transport mechanisms. Furthermore, the effect of light was found to be Ca2+-dependent. We demonstrate that reactive oxygen species (ROS) are involved in the cascade of biochemical events evoked by laser irradiation. A causal association between laser irradiation, ROS generation, and sperm function was indicated by studies with ROS scavengers, superoxide dismutase (SOD) and catalase, and exogenous hydrogen peroxide. SOD treatment resulted in increased Ca2+ uptake and in enhanced fertilization rate. Catalase treatment impaired the light-induced stimulation in Ca2+ uptake and fertilization rate. Exogenous hydrogen peroxide was found to enhance Ca2+ uptake in mouse spermatozoa and the fertilizing capability of these cells in a dose-dependent manner. These results suggest that the effect of 630 nm He-Ne laser irradiation is mediated through the generation of hydrogen peroxide by the spermatozoa and that this effect plays a significant role in the augmentation of the sperm cells' capability to fertilize metaphase II-arrested eggs in-vitro.
Iaffaldano, N; Paventi, G; Pizzuto, R; Passarella, S; Cerolini, S; Zaniboni, L; Marzoni, M; Castillo, A; Rosato, M P
2013-11-30
The effects of post-thaw Helium-Neon (He-Ne) laser irradiation on mobility and functional integrity of frozen/thawed chicken, pheasant and turkey spermatozoa were investigated. Cytochrome C oxidase (COX) activity was also determined as a measure of the effect of irradiation on mitochondrial bioenergetics. Semen samples from each species were collected, processed and frozen according to the pellet procedure. After thawing, each semen sample was divided into two subsamples: the first one was the control; the second one was irradiated with a single mode continuous He-Ne laser wave (wavelength 632.8 nm; 6 mW; 3.96 J/cm(2)). Then the samples were assessed for sperm mobility (Accudenz(®) swim-down test), viability (SYBR-14/PI staining), osmotic-resistance (HOS test) and COX activity. The irradiation was effective P<0.05 increasing sperm motility in the turkey semen (0.228 ± 0.01 compared with 0.294 ± 0.02). The irradiation also caused an increase (P<0.05) of the COX activity in pheasant (+135 ± 4%) and turkey (+116 ± 4%) sperm, without affecting viability and osmotic-resistance. The COX was positively correlated (P<0.05) with the viability of chicken sperm, however no significant interactions were found between mobility and COX activity in the three avian species. Due to the difference in energetic metabolism among avian species used in this study, the He-Ne laser irradiation has a differential action on bio-stimulation of turkey, chicken and pheasant spermatozoa. The present results are the first to elucidate the possibility for restoration of motility of cryopreserved avian spermatozoa by bio-stimulation provided via He-Ne laser irradiation. Copyright © 2013 Elsevier B.V. All rights reserved.
Application of laser therapy in treating inherited forms of psychoverbal retardation in children
NASA Astrophysics Data System (ADS)
Ulas, V. Y.; Voinova, V. M.; Il'in, L. B.; Troitskaya, L. A.; Dobrynina, E. V.; Kazantseva, L. Z.
2001-04-01
An investigation was made of applying combined laser therapy in the treatment of 619 children (422 children constituted the experimental group and 197 children composed the control group) affected by inherited forms of psychoverbal retardation. It was found that low-intensity He-Ne laser radiation with the wavelength of 632.8 nm and the output power of 2 mW made it possible to improve the children's mental development. Moreover, it effectively increased their mental activities, such as speech, communication, arbitrary behavior regulation, and locomotory functions. Laser therapy applied in treating children affected by the arrested mental development aggravated by obesity additionally decreased their body weight, increased their field of vision, and eliminated dyslipidemia. It was also found that contraindications to He-Ne laser acupuncture included phenylketonuria-related noncorrected metabolic defects, convulsive syndromes, epileptic activities, convulsive readiness, and cerebrolysine intramuscular injections.
Red and infrared gas laser beam for therapy
NASA Astrophysics Data System (ADS)
Pascu, Mihail-Lucian; Ristici, Marin; Ristici, E.; Tivarus, Madalina-Elena
2000-06-01
For the low power laser therapy, the experiments show that better results are obtained when the laser beam is an overlapping of two radiations: one in the visible region of the spectrum and the other in IR region. Also, some experiments show that for good results in biostimulation it is important to have a high coherence length of laser beam; this is not the case of the laser diodes The He-Ne laser has the best coherence, being able to generate laser radiations in visible and IR. It has tow strong laser lines: 633 nm and 1.15 micrometers . Although their gains are about the same, the available power of the red radiation is 3-4 times higher because of its larger width, when they oscillate separately. Using special dichroic mirrors for simultaneous reflection of the both liens, the laser beam will consist of the two radiations, each of them having good coherence . A 420 mm active length, 1.8 mm inner diameter He-Ne laser tube and a special designed resonator has been developed. The mirrors reflect both radiations as follows: one reflects 99.9 percent and the other, the output mirror, reflects 98 percent. There is a competition between them because these lines have a common lower level. The output power of the laser beam as 6 mW for 633 nm and 4 mW for 1.15 micrometers , respectively.
The intravascular low level laser irradiation (ILLLI) in treatment of psoriasis clinically
NASA Astrophysics Data System (ADS)
Zhu, Jing; Nie, Fan; Shi, Hong-Min
2005-07-01
Objective: The title is research curative effect of intravascular low level laser irradiation (ILLLI) in treatment of psoriasis. Method: 478 patients with psoriasis from five groups to observe their efficacy. Group1 were treated by He-Ne laser combined with drug. Group 2 were treated by semi-conductor laser combined with drug. Group 3 were treated only by He-He laser. Group 4 were treated by semi-conductor laser. Group 5 were treated only by drug. The Ridit statistical analysis was applied to all of these data. The treatment of intravascular low level laser irradiation is as follow: laser power:4-5mw, 1 hour per day and 10 days as a period combined with vit C 2.0 g iv and inhalation of O2. Results: The clinical results: the near efficient rate was 100%, in group1-4, if combined with drugs it would be better. Ridit statistical analysis showed no significant difference between group1-4, p>0.05. The efficient rate 72.97% in group5.There were showed very significant difference with group1-4, p<0.01. 2.There were no significant differences between He-Ne laser (632.8nm) and semiconductor laser(650nm); 3.The efficacy of ILLLI in psoriasis was positive correlation to the ILLLI times. Conclusions: It can improve curative effect of intravascular low levellaser irradiation (ILLLI) in treatment of psoriasis.
High-resolution interferometic microscope for traceable dimensional nanometrology in Brazil
NASA Astrophysics Data System (ADS)
Malinovski, I.; França, R. S.; Lima, M. S.; Bessa, M. S.; Silva, C. R.; Couceiro, I. B.
2016-07-01
The double color interferometric microscope is developed for step height standards nanometrology traceable to meter definition via primary wavelength laser standards. The setup is based on two stabilized lasers to provide traceable measurements of highest possible resolution down to the physical limits of the optical instruments in sub-nanometer to micrometer range of the heights. The wavelength reference is He-Ne 633 nm stabilized laser, the secondary source is Blue-Green 488 nm grating laser diode. Accurate fringe portion is measured by modulated phase-shift technique combined with imaging interferometry and Fourier processing. Self calibrating methods are developed to correct systematic interferometric errors.
Koldaş Doğan, Şebnem; Ay, Saime; Evcik, Deniz
2017-01-01
The purpose of this study was to compare the effectiveness of two different laser therapy regimens on pain, lumbar range of motions (ROM) and functional capacity in patients with chronic low back pain (CLBP). Forty nine patients with CLBP were randomly assigned into two groups. Group 1 (n= 20) received hot-pack + laser therapy 1 (wavelength of 850 nm Gallium-Aluminum-Arsenide (Ga-Al-As) laser); group 2 (n= 29) received hot-pack + laser therapy 2 (wavelength of 650 nm Helyum-Neon (He-Ne), 785 ve 980 nm Gal-Al-As combined plaque laser) for 15 sessions. Pain severity, patient's and physician's global assessments were evaluated with visual analogue scale (VAS). Modified Schober test, right and left lateral flexion measurements were done. Modified Oswestry Disability Questionnaire (MODQ) was used for evaluation of functional disability. Measurements were done before and after the treatment. After treatment there were statistically significant improvements in pain severity, patient's and physician's global assessment, ROM and MODQ scores in both groups (P< 0.05). After the treatment there were statistically significant differences between the groups in lateral flexion measurements and MODQ scores (P< 0.05) except in pain severity, Modified Schober test, patient's and physician's global assessments (P> 0.05) in favor of those patients who received combined plaque laser therapy (group 2). Laser therapy applied with combined He-Ne and Ga-Al-As provides more improvements in lateral flexion measurements and disability of the patients, however no superiority of the two different laser devices to one another were detected on pain severity.
Laser Interferometric Measurements of the Physical Properties for He, ne Gases and Their Mixture
NASA Astrophysics Data System (ADS)
Abdel-Moniem, N. M.; El-Masry, M. M.; El-Bradie, B.; El-Mekawy, F. M.
2010-04-01
A Mach-Zehner interferometer MZI illuminated with He-Ne Laser 632.8nm is used for measuring the refractive index for He, Ne gases and their mixture HeNe. The measurements are carried out at different pressures and temperatures. The error factors of the refractive index measurements for He, Ne and HeNe gases are equal to ±1.7×10-5, ±9.5×10-6 and ±7.25×10-5 respectively. Some calculations of the electrical properties are carried out such as the optical permittivity dielectric susceptibility and specific refractivity from the determination of the refractive index. Also, the molecular radii of the gases under investigation are computed then the transport coefficients (diffusion. viscosity and thermal conductivity) are calculated. All of these calculations are carried out at different pressures and temperatures. The experimental results of refractive index for the above mixture are compared with the results estimated using one of the mixing rules and a good agreement is achieved. Also, some physical parameters are compared with other values in another literatures.
NASA Astrophysics Data System (ADS)
Jamil, Yasir; Perveen, Rashida; Ashraf, Muhammad; Ali, Qasim; Iqbal, Munawar; Ahmad, Muhammad Raza
2013-04-01
Using low power continuous wave He-Ne laser irradiation of seeds, the germination characteristics, thermodynamic changes and enzyme activities as well as changes in morphological attributes were explored for wheat (Triticum aestivum L. cv. S-24) cultivar. The changes in thermodynamic properties such as change in enthalpy (ΔH), entropy generation [(ΔSe)], entropy flux [(ΔSc)], entropy generation ratio [(ΔS)e/Δt], and entropy flux ratio [(ΔS)c/Δt] showed significant (P < 0.05) changes at an energy level of 500 mJ. The germination energy (GE), germination percentage (G%), germination index (GI) as well as α-amylase and protease activities was also found to be higher at 500 mJ, while the mean emergence time (MET) and time for 50% germination (E50) decreased for 300 mJ irradiance. The internal energy of the seeds increased significantly at all laser energy levels, but was highest for 500 mJ 72 h after sowing. The enzyme activities increased up to 24 h after sowing and then declined. The activities of α-amylase and protease were found to be positively correlated with the plant physiological attributes. These results indicate that low power continuous wave He-Ne laser (632 nm) treatment has considerable biological effects on seed metabolism during germination as well as on later vegetative growth.
LPTF frequency synthesis chain: Results and improvement for the near future
DOE Office of Scientific and Technical Information (OSTI.GOV)
Touahri, D.; Zondy, J.J.; Acef, O.
1994-12-31
We have measured the frequency of the He-Ne/12 laser starting from the Cs referenced CO{sub 2}/OsO{sub 4} laboratory standard. As the laser diode stabilized on the two-photon transition in Rb seems to be a suitable reference for spectroscopic studies. (H, He ... ) and a promising standard, we are modifying our chain in order to measure frequencies around 780 nm and specially the Rb one.
Optical, Physical, and Chemical Properties of Surface Modified Titanium Dioxide Powders
2011-02-01
coefficient depends on the optical efficiency factor, QCM , the geometric cross section, G, and the particle mass as indicated by the relationship in eq 2...diffraction sensor with a RODOS powder dispersing unit. The instrument houses a HeNe laser (632.8 nm) and Fourier lens. Upon introduction of the
Chen, Yi-Ping
2009-07-01
To determine the response of antioxidant defense system to laser radiation apical meristem of Isatis indigotica seedlings, Isatis indigotica seedlings were subjected to UV-B radiation (10.08 kJ m(-2)) for 8 h day(-1) for 8 days (PAR, 220 micromol m(-2) s(-1)) and then exposed to He-Ne laser radiation (633 nm; 5.23 mW mm(-2); beam diameter: 1.5 mm) for 5 min each day without ambient light radiation. Changes in free radical elimination systems were measured, the results indicate that: (1) UV-B radiation enhanced the concentration of Malondialdahyde (MDA) and decreased the activities of superoxide dismutase (SOD), catalase (CAT) and peroxidase (POD) in seedlings compared with the control. The concentration of MDA was decreased and the activities of SOD, CAT and POD were increased when seedlings were subjected to elevated UV-B damage followed by laser; (2) the concentration of UV absorbing compounds and proline were increased progressively with UV-B irradiation, laser irradiation and He-Ne laser irradiation plus UV-B irradiation compared with the control. These results suggest that laser radiation has an active function in repairing UV-B-induced lesions in seedlings.
Interaction of Polarized Light with Chalcogenide Glasses
2001-06-01
simultaneous measurement of the laser radiation transmitted through the bulk sample and radiation scattered by the sample to various angles up to 230...fixed in the central part of the lens, reflected the transmitted light beam to a second photodiode. He-Ne laser radiation (), = 633 nm) which was sub...band-gap radiation for the studied bulk glass samples (As 2S3 glass) played in this installation, by turns, a role of inducing or probing light. This
Li, Yongfeng; Gao, Limei; Han, Rong
2016-12-01
The elevated ultraviolet-B (UV-B) stress induces the accumulation of a variety of intracellular reactive oxygen species (ROS), which seems to cause oxidative stress for plants. To date, very little work has been done to evaluate the biological effects of a combined treatment with He-Ne laser irradiation and exogenous nitric oxide (NO) application on oxidative stress resulting from UV-B radiation. Thus, our study investigated the effects of a combination with He-Ne laser irradiation and exogenous NO treatment on oxidative damages in wheat seedlings under elevated UV-B stress. Our data showed that the reductions in ROS levels, membrane damage parameters, while the increments in antioxidant contents and antioxidant enzyme activity caused by a combination with He-Ne laser and exogenous NO treatment were greater than those of each individual treatment. Furthermore, these treatments had a similar effect on transcriptional activities of plant antioxidant enzymes. This implied that the protective effects of a combination with He-Ne laser irradiation and exogenous NO treatment on oxidative stress resulting from UV-B radiation was more efficient than each individual treatment with He-Ne laser or NO molecule. Our findings might provide beneficial theoretical references for identifying some effective new pathways for plant UV-B protection.
Damage repair effect of He-Ne laser on wheat exposed to enhanced ultraviolet-B radiation.
Yang, Liyan; Han, Rong; Sun, Yi
2012-08-01
We explored the use of He-Ne laser on alleviating the effects of ultraviolet-B (UV-B) light on winter wheat development. Triticum aestivum L. cv. Linyuan 077038 seeds were irradiated with either UV-B (10.08 kJ m(-2) d(-1)) (enhanced UV-B) or a combination of UV-B light and the He-Ne laser (5.43 mW mm(-2)). Plants also were exposed to the He-Ne laser alone. Our results showed that enhanced UV-B produced negative effects on seed germination and seedling development. Germination rate and shoot growth decreased compared with the control. Root development was inhibited, and root length was decreased. Chlorophyll content and expression of peroxidase (POD) isozymes and their activity decreased. Seedling height and shoot biomass dropped significantly compared to the control. Implementing the He-Ne laser partially alleviated the injury of enhanced UV-B radiation, because germination rate and shoot growth were enhanced together with root development. Chlorophyll content and POD expression and activity increased. Seedling height and shoot biomass were increased. Furthermore, the use of the He-Ne laser alone showed a favorable effect on seedling growth compared with the control. Copyright © 2012 Elsevier Masson SAS. All rights reserved.
Dóka, Ottó; Bicanic, Dane
2002-05-01
The He-Ne laser (632.8 nm) and the concept of optothermal window (OW), a variant of the open photoacoustic cell, were combined with the Folin-Ciocalteu colorimetry assay to quantitate phenolics in four red wines. The total polyphenolic content in selected red wines varied between 786 and 1630 mg/L gallic acid equivalent (GAE) as determined by OW-Folin-Ciocalteu colorimetry, which compares well to 778 and 1614 mg/L GAE obtained for the same wines by means of classical spectrophotometry. The originality and merit of OW colorimetry used here is that, unlike what is encountered in conventional spectrometry, no intermediate dilution step is required when total polyhenolics are determined in red wine. The precision, defined as the closeness to each other of 256 replicate readings of the OW signal, is generally better than 2%.
Analysis of photothermally induced vibration in metal coated AFM cantilever
NASA Astrophysics Data System (ADS)
Kadri, Shahrul; Fujiwara, Hideki; Sasaki, Keiji
2010-05-01
We report the vibration reduction in the optically driven V-shaped AFM cantilever with 70 nm gold surface coating. The driving laser at 780 nm is intensity modulated at 1 kHz to 100 kHz and focused on the AFM cantilever surface. The cantilever vibration amplitude is monitored by HeNe probe laser. Two features are observed: high vibration amplitude of the cantilever (1) at several kHz modulation frequencies regime and (2) at around its mechanical resonance. In addition, we found that vibration at the resonance peak increases when the excitation spot is positioned farther from the free end of the cantilever.
Experimental Studies of the He-Ne Laser: Resonators and Self-Locking.
ERIC Educational Resources Information Center
Ruddock, I. S.
1980-01-01
He-Ne laser experiments suitable for an undergraduate laboratory are described. The topics covered are cavity stability, self-mode-locking coherent interactions between pulses and laser medium, and spontaneous transverse mode locking. (Author/DS)
Malinowski, Michael E.
2005-01-25
The characteristics of radiation that is reflected from carbon deposits and oxidation formations on highly reflective surfaces such as Mo/Si mirrors can be quantified and employed to detect and measure the presence of such impurities on optics. Specifically, it has been shown that carbon deposits on a Mo/Si multilayer mirror decreases the intensity of reflected HeNe laser (632.8 nm) light. In contrast, oxide layers formed on the mirror should cause an increase in HeNe power reflection. Both static measurements and real-time monitoring of carbon and oxide surface impurities on optical elements in lithography tools should be achievable.
Experience of laser radiation for treatment of oral mucous lesions of different etiologies
NASA Astrophysics Data System (ADS)
Mosesyants, Elvira N.; Zazulevskaya, Lidiya Y.; Shevtsova, Elena
1997-05-01
Laser irradiation use for treatment of different manifestations of oral mucous diseases during the last 10 years. The aim of this research was study of the results of use He-Ne laser radiation in combination with main therapy for treatment of oral mucous lesions of different aetiology. He-Ne laser irradiation use for radiation of lesions were caused by different aetiology reasons. Under the observation was 116 patients 20 - 64 years old, who had and hadn't background pathology. There were biochemical, immunological controls. Data of research confirmed positive effect of use He-Ne laser radiation.
Influence of CdS nanoparticles grain morphology on laser-induced absorption
NASA Astrophysics Data System (ADS)
Ebothé, Jean; Michel, Jean; Kityk, I. V.; Lakshminarayana, G.; Yanchuk, O. M.; Marchuk, O. V.
2018-06-01
Using external illumination of a 7 nanosecond (ns) doubled frequency Nd: YAG laser emitting at λ = 532 nm with frequency repetition 10 Hz it was established a possibility of significant changes of the absorption at the probing wavelength 1150 nm of continuous wave (cw) He-Ne laser for the CdS nanoparticles embedded into the PVA polymer matrix. The effect is observed only during the two beam laser coherent treatment and this effect is a consequence of interference of two coherent beams. It is shown a principal role of the grain morphology in the efficiency of the process, which is more important than the nanoparticle sizes. The photoinduced absorption is manifested in the space distribution of the probing laser beam. The principal role of the grain interfaces between the nanoparticle interfaces and the surrounding polymer matrix is shown. The effect is almost independent of the nanoparticle sizes. It may be used for laser operation by nanocomposites.
NASA Astrophysics Data System (ADS)
Stefanov, Ivan L.; Stoyanov, Hristiyan Y.; Petrova, Elitza; Russev, Stoyan C.; Tsutsumanova, Gichka G.; Hadjichristov, Georgi B.
2013-03-01
The depth profile of the complex refractive index of silicon ion (Si+) implanted polymethylmethacrylate (PMMA) is studied, in particular PMMA implanted with Si+ ions accelerated to a relatively low energy of 50 keV and at a fluence of 3.2 × 1015 cm-2. The ion-modified material with nano-clustered structure formed in the near(sub)surface layer of a thickness of about 100 nm is optically characterized by simulation based on reflection ellipsometry measurements at a wavelength of 632.8 nm (He-Ne laser). Being of importance for applications of ion-implanted PMMA in integrated optics, optoelectronics and optical communications, the effect of the index depth profile of Si+-implanted PMMA on the profile of the reflected laser beam due to laser-induced thermo-lensing in reflection is also analyzed upon illumination with a low power cw laser (wavelength 532 nm, optical power 10 - 50 mW).
NASA Astrophysics Data System (ADS)
Rerucha, Simon; Yacoot, Andrew; Pham, Tuan M.; Cizek, Martin; Hucl, Vaclav; Lazar, Josef; Cip, Ondrej
2017-04-01
We demonstrated that an iodine stabilized distributed Bragg reflector (DBR) diode based laser system lasing at a wavelength in close proximity to λ =633 nm could be used as an alternative laser source to the helium-neon lasers in both scientific and industrial metrology. This yields additional advantages besides the optical frequency stability and coherence: inherent traceability, wider optical frequency tuning range, higher output power and high frequency modulation capability. We experimentally investigated the characteristics of the laser source in two major steps: first using a wavelength meter referenced to a frequency comb controlled with a hydrogen maser and then on an interferometric optical bench testbed where we compared the performance of the laser system with that of a traditional frequency stabilized He-Ne laser. The results indicate that DBR diode laser system provides a good laser source for applications in dimensional (nano)metrology, especially in conjunction with novel interferometric detection methods exploiting high frequency modulation or multiaxis measurement systems.
A digital intensity stabilization system for HeNe laser
NASA Astrophysics Data System (ADS)
Wei, Zhimeng; Lu, Guangfeng; Yang, Kaiyong; Long, Xingwu; Huang, Yun
2012-02-01
A digital intensity stabilization system for HeNe laser is developed. Based on a switching power IC to design laser power supply and a general purpose microcontroller to realize digital PID control, the system constructs a closed loop to stabilize the laser intensity by regulating its discharge current. The laser tube is made of glass ceramics and its integrated structure is steady enough to eliminate intensity fluctuations at high frequency and attenuates all intensity fluctuations, and this makes it easy to tune the control loop. The control loop between discharge current and photodiode voltage eliminates the long-term drifts. The intensity stability of the HeNe laser with this system is 0.014% over 12 h.
NASA Astrophysics Data System (ADS)
Pustozerov, A.; Shandarov, V.
2017-12-01
The influence of incoherent background illumination produced by light-emitting diodes (LED's) of different average wavelengths and laser diode emitting in blue region of visible on diffraction characteristics of narrow coherent light beams of He-Ne laser due to refractive index changes of Fe-doped lithium niobate sample are studied. It has been experimentally demonstrated that nonlinear diffraction of red beams with wavelength 633 nm and diameters on full width of half maximum (FWHM) near to 15 μm may be totally compensated using background light with average wavelengths 450 - 465 nm. To provide the necessary intensity of incoherent background, the combinations of spherical and cylindrical concave lenses with blue LED and laser diode module without focusing its beam have been used.
Osteoarthrosis and nonarticular rheumatism treated by low laser
NASA Astrophysics Data System (ADS)
Antipa, Ciprian; Moldovan, Corneliu I.; Crangulescu, Nicolae; Podoleanu, Adrian Gh.; Vasiliu, Virgil V.
1995-03-01
557 patients with various noninflammatory rheumatism (osteoarthrosis and nonarticular) were treated in four different ways: with GaAs laser, 1 - 2 mW output power alone, with HeNe laser, 2 mW alone, with GaAs and HeNe together and with classical antiflammatory therapy.
Semiconductor lasers in rheumatological treatment
NASA Astrophysics Data System (ADS)
Pascu, Mihail-Lucian; Suteanu, S.; Ignat, P.; Pruna, Simion; Chitu, A.
1995-03-01
A computer controlled equipment, containing 6 lasers (HeNe and 5 diode lasers--DL) conceived to be used in rheumatological treatment is reported. DL emit at 895 nm and for typical applications, their expanded spots are superposed within the irradiation plane, on the HeNE defocused spot used to define the surface to be irradiated. DL emit 100 nsec pulses between 0.5 KHz and 1.5 KHz repetition rate and 0.5 mW average power (measured at 1 KHz). 150 patients with rheumathologic diseases were treated: lumbar spondylosis (75), gonarthrosis (30), cervical spondylosis (21), coxarthrosis (15), Heberden and Bouchard (9). The treatment consisted of: group I, 50 patients--laser therapy, 10 min/day, 10 days; group II, 50 patients--classical antirheumatic treatment; group III, 50 patients--mixed treatment. Assessment of sympathetic skin activity made using reactometry measurements, shows that latency time was longer before irradiation, 1867 +/- 289) msec then after, (1234 +/- 321) msec. Pain rating indexes decreasing for all three groups of patients were measured. Better results for more superficial diseases were obtained and best results were observed after irradiation with 1 KHz - 1.5 KHz repetition rate IR pulses. Better results were obtained when spot irradiation in a few points combined with zone irradiations was used.
Wavelength and energy dependent absorption of unconventional fuel mixtures
NASA Astrophysics Data System (ADS)
Khan, N.; Saleem, Z.; Mirza, A. A.
2005-11-01
Economic considerations of laser induced ignition over the normal electrical ignition of direct injected Compressed Natural Gas (CNG) engines has motivated automobile industry to go for extensive research on basic characteristics of leaner unconventional fuel mixtures to evaluate practical possibility of switching over to the emerging technologies. This paper briefly reviews the ongoing research activities on minimum ignition energy and power requirements of natural gas fuels and reports results of present laser air/CNG mixture absorption coefficient study. This study was arranged to determine the thermo-optical characteristics of high air/fuel ratio mixtures using laser techniques. We measured the absorption coefficient using four lasers of multiple wavelengths over a wide range of temperatures and pressures. The absorption coefficient of mixture was found to vary significantly over change of mixture temperature and probe laser wavelengths. The absorption coefficients of air/CNG mixtures were measured using 20 watts CW/pulsed CO2 laser at 10.6μm, Pulsed Nd:Yag laser at 1.06μm, 532 nm (2nd harmonic) and 4 mW CW HeNe laser at 645 nm and 580 nm for temperatures varying from 290 to 1000K using optical transmission loss technique.
NASA Astrophysics Data System (ADS)
Houssein, Hend A. A.; Jaafar, M. S.; Ramli, R. M.; Ismail, N. E.; Ahmad, A. L.; Bermakai, M. Y.
2010-07-01
In this study, the subpopulations of human blood parameters including lymphocytes, the mid-cell fractions (eosinophils, basophils, and monocytes), and granulocytes were determined by electronic sizing in the Health Centre of Universiti Sains Malaysia. These parameters have been correlated with human blood characteristics such as age, gender, ethnicity, and blood types; before and after irradiation with 0.95 mW He-Ne laser (λ = 632.8 nm). The correlations were obtained by finding patterns, paired non-parametric tests, and an independent non-parametric tests using the SPSS version 11.5, centroid and peak positions, and flux variations. The findings show that the centroid and peak positions, flux peak and total flux, were very much correlated and can become a significant indicator for blood analyses. Furthermore, the encircled flux analysis demonstrated a good future prospect in blood research, thus leading the way as a vibrant diagnosis tool to clarify diseases associated with blood.
Shu, Bin; Ni, Guo-Xin; Zhang, Lian-Yang; Li, Xiang-Ping; Jiang, Wan-Ling; Zhang, Li-Qun
2013-05-01
This study explored the inhibitory effect of the high-power helium-neon (He-Ne) laser on the growth of scars post trauma. For the in vitro study, human wound fibroblasts were exposed to the high-power He-Ne laser for 30 min, once per day with different power densities (10, 50, 100, and 150 mW/cm(2)). After 3 days of repeated irradiation with the He-Ne laser, fibroblast proliferation and collagen synthesis were evaluated. For in vivo evaluation, a wounded animal model of hypertrophic scar formation was established. At postoperative day 21, the high-power He-Ne laser irradiation (output power 120 mW, 6 mm in diameter, 30 min each session, every other day) was performed on 20 scars. At postoperative day 35, the hydroxyproline content, apoptosis rate, PCNA protein expression and FADD mRNA level were assessed. The in vitro study showed that the irradiation group that received the power densities of 100 and 150 mW/cm(2) showed decreases in the cell proliferation index, increases in the percentage of cells in the G0/G1 phase, and decreases in collagen synthesis and type I procollagen gene expression. In the in vivo animal studies, regions exposed to He-Ne irradiation showed a significant decrease in scar thickness as well as decreases in hydroxyproline levels and PCNA protein expression. Results from the in vitro and in vivo studies suggest that repeated irradiation with a He-Ne laser at certain power densities inhibits fibroblast proliferation and collagen synthesis, thereby inhibits the growth of hypertrophic scars.
Sobouti, Farhad; Khatami, Maziar; Chiniforush, Nasim; Rakhshan, Vahid; Shariati, Mahsa
2015-01-01
Pain is the most common complication of orthodontic treatment. Low-level laser therapy (LLLT) has been suggested as a new analgesic treatment free of the adverse effects of analgesic medications. However, it is not studied thoroughly, and the available studies are quite controversial. Moreover, helium neon (He-Ne) laser has not been assessed before. This split-mouth placebo-controlled randomized clinical trial was performed on 16 male and 14 female orthodontic patients requiring bilateral upper canine retraction. The study was performed at a private clinic in Sari, Iran, in 2014. It was single blind: patients, orthodontist, and personnel were blinded of the allocations, but the laser operator (periodontist) was not blinded. Once canine retractor was activated, a randomly selected maxillary quarter received a single dose of He-Ne laser irradiation (632.8 nm, 10 mw, 6 j/cm(2) density). The other quarter served as the placebo side, treated by the same device but powered off. In the first, second, fourth, and seventh days, blinded patients rated their pain sensed on each side at home using visual analog scale (VAS) questionnaires. There was no harm identified during or after the study. Pain changes were analyzed using two- and one-way repeated-measures ANOVA, Bonferroni, and t-test (α = 0.01, β > 0.99). This trial was not registered. It was self-funded by the authors. Sixteen males and 11 females remained in the study (aged 12-21). Average pain scores sensed in all 4 intervals on control and laser sides were 4.06 ± 2.85 and 2.35 ± 1.77, respectively (t-test P < 0.0001). One-way ANOVA showed significant pain declines over time, in each group (P < 0.0001). Two-way ANOVA showed significant effects for LLLT (P < 0.0001) and time (P = <0.0001). Single-dose He-Ne laser therapy might reduce orthodontic pain caused by retracting maxillary canines.
NASA Astrophysics Data System (ADS)
Mittal, Subhangi; Roy, Sukhdev; Srivastava, J. N.
2013-05-01
We report the efficacy of an aqueous extract of Beta vulgaris as a novel, natural photosensitizer for use in photodynamic therapy against Candidiasis disease. This study evaluates the effect of different laser wavelengths (He-Ne: 633 nm, Nd-YAG: 532 nm), power (17, 27 mW) and duration of exposure (5, 10, 15 min) in combination with the Beta vulgaris natural photosensitizer on the viability of Candida albicans causing Candidiasis disease. Although inhibition was observed in all cases, a maximum of 51.91% inhibition takes place with the combination of Beta vulgaris exposed to 532 nm at 27 mW for 15 min by the Agar well diffusion method. The study is important in optimizing different parameters and designing a low-power, compact, non-invasive and portable device for treatment.
Rapid Identification of Micro-Organisms.
1985-08-26
mixed cell populations to which this technology has been applied, although many similarities exist as well. In most applications of flow cytometry, it...specific nucleic acid sequences detectable with DNA probes, are applicable only to organisms previously know to and available to the laboratory workers...peak of phycoerythrin, and the 585/593 nm yellow emission from He-Ne lasers now in development is well suited for excitation of phycocyanin . Any of the
A six-color four-laser mobile platform for multi-spectral fluorescence imaging endoscopy
NASA Astrophysics Data System (ADS)
Black, John F.; Tate, Tyler; Keenan, Molly; Swan, Elizabeth; Utzinger, Urs; Barton, Jennifer
2015-03-01
The properties of multi-spectral fluorescence imaging using deep-UV-illumination have recently been explored using a fiber-coupled thermal source at 280 nm. The resulting images show a remarkable level of contrast thought to result from the signal being overwhelmingly generated in the uppermost few cell layers of tissue, making this approach valuable for the study of diseases that originate in the endothelial tissues of the body. With a view to extending the technique with new wavelengths, and improving beam quality for efficient small core fiber coupling we have developed a mobile self-contained tunable solid-state laser source of deep UV light. An alexandrite laser, lasing at around 750 nm is frequency doubled to produce 375 nm and then tripled to produce 250 nm light. An optical deck added to the system allows other laser sources to be incorporated into the UV beam-line and a lens system has been designed to couple these sources into a single delivery fiber with core diameters down to 50 microns. Our system incorporates five wavelengths [250 nm, 375 nm, 442 nm (HeCd), 543 nm (HeNe) and 638 nm (diode laser)] as the illumination source for a small diameter falloposcope designed for the study of the distal Fallopian tube origins of high grade serous ovarian cancer. The tunability of alexandrite offers the potential to generate other wavelengths in the 720-800, 360-400 and 240-265 nm ranges, plus other non-linear optical conversion techniques taking advantage of the high peak powers of the laser.
Effect of low-power (He-Ne) laser on acute mucosal ulceration induced by indomethacin in rats
NASA Astrophysics Data System (ADS)
Djavid, Gholam-reza E.; Erfani, Rebecca; Amoohashemi, Nasim; Pazoki, Mahbobeh; Aghaee, Sanaz; Toroudi, Hamidreza P.
2002-10-01
Background: Low-level laser has been used for treatment of ulcer, as well as, pain relief and inflammatory processes. In the present work, the effect of low power laser on mucosal gastric ulceration-induced by indomethacin in rats has been investigated. Materials and Methods: 16 male Sprague Dawley rats were divided into control (8 rats) and laser exposed group (8 rats). After using ether for anesthesia, 30 mg/kg indomethacin was injected subcutaneously. Exposed stomachs received 30 J He-Ne laser. Five hours later animals were killed and their stomachs were checked and observed for presence of ulceration. Results and Discussion: Gastric mucosal ulceration index was significantly greater in the laser-exposed group than control group. (P=0.02) This experiment suggests that low power He-Ne laser intensified acute mucosal ulcer formation by indomethacin. Changes in the prostaglandin content ofthe stomach may be responsible for these results.
Effect of helium-neon laser irradiation on hair follicle growth cycle of Swiss albino mice.
Shukla, S; Sahu, K; Verma, Y; Rao, K D; Dube, A; Gupta, P K
2010-01-01
We report the results of a study carried out to investigate the effect of helium-neon (He-Ne) laser (632.8 nm) irradiation on the hair follicle growth cycle of testosterone-treated and untreated mice. Both histology and optical coherence tomography (OCT) were used for the measurement of hair follicle length and the relative percentage of hair follicles in different growth phases. A positive correlation (R = 0.96) was observed for the lengths of hair follicles measured by both methods. Further, the ratios of the lengths of hair follicles in the anagen and catagen phases obtained by both methods were nearly the same. However, the length of the hair follicles measured by both methods differed by a factor of 1.6, with histology showing smaller lengths. He-Ne laser irradiation (at approximately 1 J/cm(2)) of the skin of both the control and the testosterone-treated mice was observed to lead to a significant increase (p < 0.05) in % anagen, indicating stimulation of hair growth. The study also demonstrates that OCT can be used to monitor the hair follicle growth cycle, and thus hair follicle disorders or treatment efficacy during alopecia. (c) 2009 S. Karger AG, Basel.
Ultrastructure observation of middle ear mucosa with laser irradiation
NASA Astrophysics Data System (ADS)
Kang, Mengkui; Yang, Shulan; Fang, Yaoyun; Sun, Jianhe
1998-08-01
In order to study the effects of He-Ne laser on the mucosa of middle ear mucosa from 9 patients with chronic otitis media, all of who had slight damp eardrum, were irradiated by low power He-Ne laser ten minutes per day for ten days. Specimen was taken before and after irradiation and observed under scanning electron microscope. It was found that the surface structure of the mucosa was more integral, the arrangement of the epithelial cell was closer together and microvilli arose among the noncilliated cells after irradiation. The inflammatory cell disappeared arid the morphologic structure appeared normal. These data provided the therapeutic evidence for the lower power He-Ne laser irradiation on patients with chronic purulent otitis midia.
Methodology of mycobacteria tuberculosis bacteria detection by Raman spectroscopy
NASA Astrophysics Data System (ADS)
Zyubin, A.; Lavrova, A.; Manicheva, O.; Dogonadze, M.; Tsibulnikova, A.; Samusev, I.
2018-01-01
We have developed a methodology for the study of deactivated strains of Mycobacterium tuberculosis. Strains of the Beijing species obtained from pulmonary patient secrete (XDR strain) and reference strain (H37Rv) were investigated by Raman spectrometry with He-Ne (632,8 nm) laser excitation source. As a result of the research, the optimal experimental parameters have been obtained to get spectra of mycolic acids, which are part of the cell wall of mycobacteria.
Direct laser interference patterning of ophthalmic polydimethylsiloxane (PDMS) polymers
NASA Astrophysics Data System (ADS)
Sola, D.; Lavieja, C.; Orera, A.; Clemente, M. J.
2018-07-01
The inscription of diffractive elements in ophthalmic polymers and ocular tissues to induce refractive index changes is of great interest in the fields of Optics and Ophthalmology. In this work fabrication of linear periodic patterns in polydimethylsiloxane (PDMS) intraocular lenses by means of the direct laser interference patterning (DLIP) technique was studied. A Q-Switch Nd:YAG laser coupled to second and third harmonic modules emitting linearly polarized 4 ns pulses at 355 nm with 20 Hz repetition rate was used as the laser source. Laser processing parameters were modified to produce the linear patterns. Processed samples were characterized by means of optical confocal microscopy, Scanning Electron Microscopy SEM, Energy Dispersive X-ray Spectroscopy EDX, Attenuated Total Reflectance-Infrared Spectroscopy ATR-FTIR, and Raman Spectroscopy. Depending on the laser parameters both photo-thermal and photo-chemical damage were observed in the DLIP irradiated areas. Finally, diffractive techniques were used to characterize the diffraction gratings inscribed in the samples resulting in a refractive index change of 1.9 × 10-2 under illumination of a 632.8 nm He-Ne laser.
Efficacy of fractional lasers in treating alopecia: a literature review.
Perper, Marina; Aldahan, Adam S; Fayne, Rachel A; Emerson, Christopher P; Nouri, Keyvan
2017-11-01
Hair loss stemming from different types of alopecia, such as androgenic alopecia and alopecia areata, negatively affects over half the population and, in many circumstances, causes serious psychosocial distress. Current treatment options for alopecia, such as minoxidil, anthralin, and intralesional corticosteroids, vary efficacy and side effect profiles. It is known that low-level laser/light therapies (LLLT), or photobiomodulations, such as the US FDA-cleared HairMax Lasercomb®, He-Ne laser, and excimer laser, are relatively affordable, user-friendly, safe, and effective forms of treatment for hair loss. While less is known about the effectiveness of fractional lasers for combating hair loss, research suggests that by creating microscopic thermal injury zones, fractional lasers may cause an increase in hair growth from a wound healing process, making them potential therapeutic options for alopecia. A literature review was performed to evaluate the effectiveness of fractional lasers on hair regrowth. The specific fractional laser therapies include the 1550-nm nonablative fractional erbium-glass laser, the ablative fractional 2940-nm erbium:YAG laser, and the ablative fractional CO 2 fractional laser. Additional randomized controlled trials are necessary to further evaluate the effectiveness of the lasers, as well as to establish appropriate parameters and treatment intervals.
Laser fluorescence spectrometers for medical diagnosis
NASA Astrophysics Data System (ADS)
Kwasny, Miroslaw; Mierczyk, Zygmunt
2000-11-01
The paper presents fibre fluorescence analysers for in vivo examined biological tissues. The systems devoted to clinical investigations are equipped with laser excitation sources; He-Cd (442 nm), Nd:YAG (II and III harmonic: 532 and 355 nm, respectively) and He-Ne (632.8 nm). They allow non-invasive determination of endogenous fluorophones level in any organs as well as monitoring of external sensitisers level when photodynamic method of diagnosis and treatment of tumors is used. Selection of various wavelengths within the range of porphyrines, excitation depends on different light penetration in various tissues. For the tumors localised under mucous membrane, UV, violet, and blue radiation was used for excitation and for deeply localised tumors, a radiation of longer wavelengths (green and red) was used. The carried out clinical examinations showed usefulness of fluorometric systems for diagnostics of skin diseases, gynaecological spheres, and pneumopathies. These analysers can be also applied for environmental protection, food control, and industrial processes monitoring.
Low-level He-Ne laser in intravascular irradiation treatment of schizophrenia
NASA Astrophysics Data System (ADS)
Zhou, Yu-Xue; Fu, Zheng-Hua
1998-11-01
Intravascular low level He-Ne laser irradiation is a new therapy developed in recent years. In our hospital it was applied in the treatment and observation of 220 cases of schizophrenia, among which certain effect was achieved and about which the detail was collated and elaborated.
Airborne Visible Laser Optical Communications (AVLOC) experiment
NASA Technical Reports Server (NTRS)
1974-01-01
A series of optical communication experiments between a high altitude aircraft at 18.3 km (60,000 ft) and a ground station were conducted by NASA from summer 1972 through winter 1973. The basic system was an optical tracker and transmitter located in each terminal. The aircraft transceiver consisted of a 5-mW HeNe laser transmitter with a 30-megabit modulator. The ground station beacon was an argon laser operating at 488 nm. A separate pulsed laser radar was used for initial acquisition. The objective of the experiment was to obtain engineering data on the precision tracking and communication system performance at both terminals. Atmospheric effects on the system performance was also an experiment objective. The system description, engineering analysis, testing, and flight results are discussed.
NASA Astrophysics Data System (ADS)
Zhu, Jian; Liang, Min-yi; Cao, Hao-cai; Li, Xiao-Yuan; Li, Shao-ming; Li, Shun-hao; Li, Wen-qi; Zhang, Jin-hong; Liu, Lei; Lai, Jian-hong
2005-07-01
Objective: To explore the efficacy of He-Ne laser intravascular irradiation on infarction and hemorrheology. To observe the effects of intravascular low level He-Ne laser irradiation (ILLLI) of blood on cell proliferation, apoptosis and chromosome in lymphocyte from cerebral infarction Methods: Seventy cases with cerebral infarction were randomly divided into groups control group (35 cases) treated only with common drugs and therapeutic group (35 cases) treated besides common drugs also by He-Ne laser intravascular irradiation. Their hemorrheology index and treatment results were observed and compared. The blood lymphocytes of cerebral infarction were cultured before and after treatment. After that, the mitosis index (MI), cell kinetics index (CKI), sister-chromatid exchanges (SCE) frequencies and apoptosis were determined. Results The therapeutic group was better than the control one. The effective rate in the therapeutic group was 88.6%, in the control one was 65.7%. The viscosity and fibrinogen, etc were better than that in the control group with significant difference (P<0.01). The lymphocyte proliferation index was significantly two increased than the control one (P>0.05) in cerebral infarction patients after treatment; The CKI of lymphocytes had no obvious difference among groups (P>0.05) SCE frequencies of lymphocytes had no statistic significance between control group and ILLLI on (P>0.05). It showed the apoptosis rate of lymphocytes in cerebral infarction patients after ILLLI treatment increased significantly compared with the control group, (P<0.001). There was a significant difference of apoptosis rate of lymphocytes in cerebral infarction patients than the control (P<0.001). Conclusions: During the He-Ne laser intravascular irradiation of the cerebral infarction, the low level He-Ne by ILLLI can increase the proliferation of lymphocytes, and can induce lymphocytes to apoptosis, but has no mutagenicity of cells.
NASA Astrophysics Data System (ADS)
Kuusela, Tom A.
2017-09-01
A He-Ne laser is an example of a class A laser, which can be described by a single nonlinear differential equation of the complex electric field. This laser system has only one degree of freedom and is thus inherently stable. A He-Ne laser can be driven to the chaotic condition when a large fraction of the output beam is injected back to the laser. In practice, this can be done simply by adding an external mirror. In this situation, the laser system has infinite degrees of freedom and therefore it can have a chaotic attractor. We show the fundamental laser equations and perform elementary stability analysis. In experiments, the laser intensity variations are measured by a simple photodiode circuit. The laser output intensity time series is studied using nonlinear analysis tools which can be found freely on the internet. The results show that the laser system with feedback has an attractor of a reasonably high dimension and that the maximal Lyapunov exponent is positive, which is clear evidence of chaotic behaviour. The experimental setup and analysis steps are so simple that the studies can even be implemented in the undergraduate physics laboratory.
Optical vibration measurement of mechatronics devices
NASA Astrophysics Data System (ADS)
Yanabe, Shigeo
1993-09-01
An optical vibration measuring system which enables to detect both linear and angular displacement of 25 nm and 5 prad was developed. The system is mainly composed of a He-Ne laser, a displacement detecting photo-diode and lenses, and has linear and angular displacement magnification mechanism using two different principles of optical lever. The system was applied to measure vibrational characteristics of magnetic head slider of hard disk drives and to measure stator teeth driving velocities of ultrasonic motor.
NASA Astrophysics Data System (ADS)
Velez-Gonzalez, Mariano; Urrea-Arbelaez, Alejandro; Nicolas, M.; Serra-Baldrich, E.; Perez, J. L.; Pavesi, M.; Camarasa, J. M.; Trelles, Mario A.
1996-01-01
Sixty patients (greater than 16 yrs old) suffering primary or relapse genital herpes simplex viruses (HSV) and relapse labial HSV were appointed for this study. Three or more relapses were experienced per year. Patients (under treatment) were divided into two groups (distribution areas), corresponding to either labial herpes or genital herpes. These groups were sub-divided into 3 groups. The total number of labial or facial HSV patients was 36 (10 in group 1, 12 in group 2, 14 in group 3) and 24 for genital, buttocks, or 'area pudenda' HSV patients (6 in group 1, 8 in group 2, 10 in group 3). The design was a randomized, double- blind study. The setting was hospital and outpatient. The patients diagnosed as having the HVS disease were sent to the dermatology department and were assigned to a group at random. Treatment was begun as follows: During the treatment signs and symptoms were assessed and after the treatment, the relapses were also assessed (biochemical and hematological tests before and after the treatment) and the diagnosis of the HSV type I and II. The statistical evaluation of the results was performed and carried out with the SPSS and BMDP program. The relapses of the herpes infection in the lips and the face were significantly reduced (p less than 0.026) in patients treated with laser He-Ne and laser He-Ne plus Acyclovir. The interim between the relapses also increased significantly (p less than 0.005) in relation with the group treated with Acyclovir. The duration of the herpetic eruptions was clearly reduced in all locations in patients treated with laser He-Ne plus Acyclovir. No differences were noted between patients treated with laser He-Ne only or Acyclovir only. Therefore it is probable that therapeutic synergism took place. In relation with this, laser He-Ne shows the same therapeutic efficacy as Acyclovir taken orally. The association of Acyclovir and laser Ne-Ne could be an alternative method for the treatment of HSV in the face. The number of relapses of the herpes infection in the genital, buttocks or 'area pudenda' and the interim between the relapses were not substantially modified with the treatment of laser He-Ne or laser Ne-Ne plus Acyclovir. Although a little difference exists in comparison with the patients treated with Acyclovir alone, a survey or an increased number of patients should be necessary.
Histological effects of He-Ne laser on the healing of experimental colon anastomoses in the rat
NASA Astrophysics Data System (ADS)
Asencio-Arana, Francisco; Torres-Gil, Vicente; Martinez-Soriano, Francisco; Perez-Sarrio, R.
1990-06-01
Despite technical advances, the incidence of anastomotic leaks in elective colorectal surgery remains around 14%, Recent studies suggest that the use of low energy lasers may enhance wound healing in different tissues in a selective, nondestructive manner. Based on these findings we have attempted to provide experimental background on the histological effects of He-Ne laser during the early stages of healing in 70 colonic anastornoses performed on rats, The irradiation of the anastomoses by two doses of 3.6 J/cm produces an increase in the populations of round cells and fibroblasts of the scar tissue, an increase in new vessel formation and a significant improvement in epithelialization. This suggests that the irradiation of colonic wounds with He-Ne lasers can result in an enhancement of healing.
NASA Astrophysics Data System (ADS)
Prabhu, Vijendra; Rao, Bola Sadashiva S.; Mahato, Krishna Kishore
2014-02-01
Investigations on the use of Low Level Laser Therapy (LLLT) for wound healing especially with the red laser light have demonstrated its pro-healing potential on a variety of pre-clinical and surgical wounds. However, until now, in LLLT the effect of multiple exposure of low dose laser irradiation on acute wound healing on well-designed pre-clinical model is not much explored. The present study aimed to investigate the effect of multiple exposure of low dose Helium Neon laser on healing progression of full thickness excision wounds in Swiss albino mice. Further, the efficacy of the multiple exposure of low dose laser irradiation was compared with the single exposure of optimum dose. Full thickness excision wounds (circular) of 15 mm diameter were created, and subsequently illuminated with the multiple exposures (1, 2, 3, 4 and 5 exposure/ week until healing) of He-Ne (632.8 nm, 4.02 mWcm-2) laser at 0.5 Jcm-2 along with single exposure of optimum laser dose (2 J/cm-2) and un-illuminated controls. Classical biophysical parameters such as contraction kinetics, area under the curve and the mean healing time were documented as the assessment parameters to examine the efficacy of multiple exposures with low level laser dose. Experimental findings substantiated that either single or multiple exposures of 0.5 J/cm2 failed to produce any detectable alterations on wound contraction, area under the curve and mean healing time compared to single exposure of optimum dose (2 Jcm-2) and un-illuminated controls. Single exposure of optimum, laser dose was found to be ideal for acute wound healing.
Laser speckle tracking for monitoring and analysis of retinal photocoagulation
NASA Astrophysics Data System (ADS)
Seifert, Eric; Bliedtner, Katharina; Brinkmann, Ralf
2014-02-01
Laser coagulation of the retina is an established treatment for several retinal diseases. The absorbed laser energy and thus the induced thermal damage varies with the transmittance and scattering properties of the anterior eye media and with the pigmentation of the fundus. The temperature plays the most important role in the coagulation process. An established approach to measure a mean retinal temperature rise is optoacoustics, however it provides limited information on the coagulation. Phase sensitive OCT potentially offers a three dimensional temporally resolved temperature distribution but is very sensitive to slightest movements which are clinically hard to avoid. We develop an optical technique able to monitor and quantify thermally and coagulation induced tissue movements (expansions and contractions) and changes in the tissue structure by dynamic laser speckle analysis (LSA) offering a 2D map of the affected area. A frequency doubled Nd:YAG laser (532nm) is used for photocoagulation. Enucleated porcine eyes are used as targets. The spot is 100μm. A Helium Neon laser (HeNe) is used for illumination. The backscattered light of a HeNe is captured with a camera and the speckle pattern is analyzed. A Q-switched Nd:YLF laser is used for simultaneous temperature measurements with the optoacoustic approach. Radial tissue movements in the micrometer regime have been observed. The signals evaluation by optical flow algorithms and generalized differences tuned out to be able to distinguish between regions with and without immediate cell damage. Both approaches have shown a sensitivity of 93% and a specificity above 99% at their optimal threshold.
Characterization of cells and bacteria by photophoretic velocimetry
NASA Astrophysics Data System (ADS)
Helmbrecht, Clemens; Niessner, Reinhard; Haisch, Christoph
2008-02-01
The migration induced by intensive light is termed photophoresis. We could show that the evaluation of light-induced velocities of microparticles, bacteria and cells suspended in water is valuable for the prediction of their intrinsic properties. Two different laser setups were evaluated for photophoretic migration, a He-Ne laser (P = 45 mW, λ = 633 nm) and a diode-pumped cw-Nd:YAG (P = 1.1 W, λ = 532 nm). When analyzing the migration behavior of particles, we find significant differences depending on both, geometrical size and refractive index. We describe migration of PS particles of different size as well as with different refractive index but same diameter, SiO II and melamine resin. The potential for the separation of biological matter is shown as velocity distributions of heat killed bacteria of Escherichia coli, Salmonella enteritidis, and baker's yeast is reported.
Research on optical properties of dental enamel for early caries diagnostics using a He-Ne laser
NASA Astrophysics Data System (ADS)
Tang, Jing; Liu, Li; Li, Song-zhan
2008-12-01
A new and non-invasive method adapted for optical diagnosis of early caries is proposed by researching on the interaction mechanism of laser with dental tissue and relations of remitted light with optical properties of the tissue. This method is based on simultaneous analyses of the following parameters: probing radiation, backscattering and auto-fluorescence. Investigation was performed on 104 dental samples in vitro by using He-Ne laser (λ=632.8nm, 2.0+/-0.1mW) as the probing. Spectrums of all samples were obtained. Characteristic spectrums of dental caries in various stages (intact, initial, moderate and deep) were given. Using the back-reflected light to normalize the intensity of back-scattering and fluorescence, a quantitative diagnosis standard for different stages of caries is proposed. In order to verify the test, comparison research was conducted among artificial caries, morphological damaged enamel, dental calculus and intact tooth. Results show that variations in backscattering characteristic changes in bio-tissue morphological and the quantity of auto-fluorescence is correlated with concentration of anaerobic microflora in hearth of caries lesion. This method poses a high potential of diagnosing various stages of dental caries, and is more reliability to detect early caries, surface damage of health enamel and dental calculus.
Bidirectional scattering of light from tree leaves
NASA Technical Reports Server (NTRS)
Brakke, Thomas W.; Smith, James A.; Harnden, Joann M.
1989-01-01
A laboratory goniometer consisting of an He-Ne laser (632.8 nm), vertical leaf holder, and silicon photovoltaic detector was used to measure the bidirectional scattering (both transmittance and reflectance) of red oak and red maple. The illumination angles were 0, 30, and 60 deg, and the scattering was recorded approximately every 10 deg in the principal plane. The scattering profiles obtained show the non-Lambertian characteristics of the scattering, particularly for the off-nadir illumination directions. The transmitted light was more isotropic than the reflected light.
1986-10-31
constructed from TeO2 sisting of lenses L6 and L- and a cylindrical lens C- material which is oriented to operate in the slow shear shape the Bragg...to focus the light into a horizontal line for efficient illumination. The Bragg cells are constructed from TeO2 material which is oriented to operate...source is a 10 mW He-Ne laser for which = 632.8 nm. The holographic element was constructed on a SO-120 glass plate with a reference-to-signal beam
2007-11-01
waveguide approach in which a right-angled gadolinium gallium garnet (GGG) glass prism of index 1.965 at 633 nm is used to couple light from a HeNe laser of...SPARROW sensor consists of two planar, single mode aluminum oxide waveguides separated vertically by a lower refractive index silicon dioxide layer...and high stability could be formed on aluminum oxide, the binding of an alkyl carboxylic acid, stearic acid (n-octadecanoic acid), was investigated
The effect of He-Ne and Ga-Al-As lasers on the healing of oral mucosa in diabetic mice.
Fahimipour, Farahnaz; Houshmand, Behzad; Alemi, Parvin; Asnaashari, Mohammad; Tafti, Mahmoud Akhavan; Akhoundikharanagh, Fatemeh; Farashah, Seyed Emadeddin Najafi; Aminisharifabad, Mohammad; Korani, Aghdas Setoudehnia; Mahdian, Mina; Bastami, Farshid; Tahriri, Mohammadreza
2016-06-01
Delayed wound healing is one of the complications of diabetes mellitus. Low-level laser therapy (LLLT) has been used to accelerate wound healing however the effect of LLLT on the hard palate wound healing in streptozotocin-induced diabetic (STZ-D) mice has not yet been characterized. This study aims to determine the effect of LLLT (He-Ne and Ga-Al-As laser) on the process of wound healing in the hard palate among diabetic and non-diabetic mice. 90 adult male mice were divided into six groups. Type 1 diabetes mellitus was induced in three groups by means of injection of STZ. Of these, one group was irradiated with He-Ne laser (DH group), one with Ga-Al-As laser (DG group) and one did not undergo any LLLT (DC group). The remaining groups were non-diabetic which were allotted to laser therapy with He-Ne laser (NH group) or with Ga-Al-As laser (NG group) or no LLLT (NC group). Five animals from each group were killed on the third, seventh, and fourteenth days after surgery, and biopsies were made for histological analysis. On the 3rd and 7th days after the surgery, the number of polymorphonuclear (PMN) cells in NH, DH, NG, and DG groups was significantly lower than that of the control groups. On the 3rd, 7th and 14th days, the fibroblasts and new blood vessel counts and collagen fibers in diabetic laser treated groups (DG and DH) were significantly higher compared to that of NC, DC, NH and NG groups. On the 7th and 14th days, the fibroblasts and new blood vessel counts and collagen fibers in NH, DH, NG, and DG groups were also significantly higher than that of the control groups, and the fibroblast and new blood vessel counts and collagen density fibers in NH and DH groups were higher than that of the NG and DG groups. LLLT with He-Ne laser compared to Ga-Al-As laser has a positive healing effect on hard palate gingival wounds in STZ-D mice. Copyright © 2016 Elsevier B.V. All rights reserved.
Yokoyama, Kozo; Sugiyama, Kazuna
2003-02-01
To investigate the influence of linearly polarized near-infrared irradiation using the Super Lizer trade mark on deformability of human erythrocytes. Not only low-powered laser but also linearly polarized near-infrared beams have some biostimulation effects on various tissues. There were some reports of erythrocyte deformability improved by low-powered He-Ne laser irradiation. Human erythrocyte samples stored for three weeks were adjusted to 30% hematocrit. Erythrocyte deformability presented as the filter filtration rate was measured. There was no difference of the filter filtration rate between control group without irradiation and the group of 125 mJ/cm(2) exposure level at a wavelength of 830 nm. However, the groups of 625 and 1,250 mJ/cm(2) exposure levels at a wavelength of 830 nm showed higher filter filtration rates compared to the control group. Linearly polarized near-infrared irradiation in a range of 625-1,250 mJ/cm(2) exposure level at a wavelength of 830 nm improved deformability of human stored erythrocytes.
Modulatory frequency of lasers in connection to laser beam therapeutic effect
NASA Astrophysics Data System (ADS)
Kucerova, Hana; Bartova, Jirina; Himmlova, Lucia; Dostalova, Tatjana; Mazanek, Jiri
1998-04-01
The subject of this work follows changes of the sIgA and albumin levels in the saliva of 48 patients treated after the extraction of their lower molars with either diode or He-Ne biostimulatory laser, using different modulatory frequencies (5 Hz, 292 Hz, 9000 Hz). The results were compared to the sIgA and albumin levels in the saliva of the control, i.e. not- treated group. For the tests radial immunodiffusion (RID) method was used (commercial RID kit of the Binding Site, Birmingham, Great Britain). Appropriately chosen laser beam modulatory frequency should influence the increase in the sIgA and albumin levels against the base level. In our study, this hypothesis was confirmed in the group treated with the frequency of 292 Hz and 9000 Hz (both diode GaAIAs, 670 nm, red, 20 mW, energy density 1.5 Jcm2) on albumin levels and 9000 Hz on sIgA levels. The changes of the levels of the watched markers versus the control group were at this frequencies (292 Hz and 9000 Hz) statistically significant. At the others used frequencies (5 Hz diode laser and 5 Hz He-Ne laser) the changes of the levels of the watched markers versus control group were statistically insignificant. The aim of this study was to contribute to the evaluation of specific modulatory frequencies (5 Hz, 292 Hz, 9000 Hz) for therapeutical use in a given pathological case of the oral cavity. We can conclude that using frequency 9000 Hz had best immunomodulatory effect.
Lateral scattered light used to study laser light propagation in turbid media phantoms
NASA Astrophysics Data System (ADS)
Valdes, Claudia; Solarte, Efrain
2010-02-01
Laser light propagation in soft tissues is important because of the growing biomedical applications of lasers and the need to optically characterize the biological media. Following previous developments of the group, we have developed low cost models, Phantoms, of soft tissue. The process was developed in a clean room to avoid the medium contamination. Each model was characterized by measuring the refractive index, and spectral reflectance and transmittance. To study the laser light propagation, each model was illuminated with a clean beam of laser light, using sources such as He-Ne (632nm) and DPSSL (473 nm). Laterally scattered light was imaged and these images were digitally processed. We analyzed the intensity distribution of the scattered radiation in order to obtain details of the beam evolution in the medium. Line profiles taken from the intensity distribution surface allow measuring the beam spread, and to find expressions for the longitudinal (along the beam incident direction) and transversal (across the beam incident direction) intensities distributions. From these behaviors, the radiation penetration depth and the total coefficient of extinction have been determined. The multiple scattering effects were remarkable, especially for the low wavelength laser beam.
NASA Astrophysics Data System (ADS)
Fallahnezhad, Somaye; Piryaei, Abbas; Tabeie, Faraj; Nazarian, Hamid; Darbandi, Hasan; Amini, Abdoldllah; Mostafavinia, Ataroalsadat; Ghorishi, Seyed Kamran; Jalalifirouzkouhi, Ali; Bayat, Mohammad
2016-09-01
The purpose of this study was to evaluate the influences of helium-neon (He-Ne) and infrared (IR) lasers on the viability and proliferation rate of healthy and ovariectomy-induced osteoporotic (OVX) bone marrow mesenchymal stem cells (BMMSCs) in vitro. MSCs harvested from the BM of healthy and OVX rats were culture expanded. He-Ne and IR lasers were applied three times at energy densities of 0.6, 1.2, and 2.4 J/cm2 for BMMSCs. BMMSCs viability and proliferation rate were evaluated by MTT assay on days 2, 4, 6, 14, and 21. The results showed that healthy BMMSCs responded optimally to 0.6 J/cm2 using an IR laser after three times of laser radiation. Moreover, it was found that OVX-BMMSCs responded optimally to 0.6 J/cm2 with He-Ne laser and one-time laser radiation. It is concluded that the low-level laser therapy (LLLT) effect depends on the physiological state of the BMMSCs, type of the laser, wavelength, and number of laser sessions. The biostimulation efficiency of LLLT also depends on the delivered energy density. LLLT can enhance the viability and proliferation rate of healthy and especially osteoporotic autologous BMMSCs, which could be very useful in regenerative medicine.
The second-order interference of two independent single-mode He-Ne lasers
NASA Astrophysics Data System (ADS)
Liu, Jianbin; Le, Mingnan; Bai, Bin; Wang, Wentao; Chen, Hui; Zhou, Yu; Li, Fu-li; Xu, Zhuo
2015-09-01
The second-order spatial and temporal interference patterns with two independent single-mode continuous-wave He-Ne lasers are observed when these two lasers are incident to two adjacent input ports of a 1:1 non-polarizing beam splitter, respectively. Two-photon interference based on the superposition principle in Feynman's path integral theory is employed to interpret the experimental results. The conditions to observe the second-order interference pattern with two independent single-mode continuous-wave lasers are discussed. It is concluded that frequency stability is important to observe the second-order interference pattern with two independent light beams.
Spectral fluorescent properties of tissues in vivo with excitation in the red wavelength range
NASA Astrophysics Data System (ADS)
Stratonnikov, Alexander A.; Loschenov, Victor B.; Klimov, D. V.; Edinac, N. E.; Wolnukhin, V. A.; Strashkevich, I. A.
1997-12-01
The spectral fluorescence analysis is a promising method for differential tissue diagnostic. Usually the UV and visible light is used for fluorescence excitation with emission registration in the visible wavelength range. The light penetration length in this wavelength range is very small allowing one to analyze only the surface region of the tissue. Here we present the tissue fluorescent spectra in vivo excited in the red wavelength region. As excitation light source we used compact He-Ne laser (632.8 nm) and observed the fluorescence in 650 - 800 nm spectral range. The various tissues including normal skin, psoriasis, tumors, necrosis as well as photosensitized tissues have been measured.
NASA Astrophysics Data System (ADS)
Kim, Charlton C.; Wallace, Vincent P.; Rasouli, Alexandre; Coleno, Mariah L.; Dao, Xavier; Tromberg, Bruce J.; Wong, Brian J.
2000-05-01
Laser irradiation of hyaline cartilage result in stable shape changes due to temperature dependent stress relaxation. In this study, we determined the structural changes in chondrocytes within porcine nasal septal cartilage tissue over a 4-day period using a two-photon laser scanning microscope (TPM) following Nd:YAG laser irradiation (lambda equals 1.32 micrometer) using parameters that result in mechanical stress relaxation (6.0 W, 5.4 mm spot diameter). TPM excitation (780 nm) result in induction of fluorescence from endogenous agents such as NADH, NADPH, and flavoproteins in the 400 - 500 nm spectral region. During laser irradiation diffuse reflectance (from a probe HeNe laser, (lambda) equals 632.8 nm), surface temperature, and stress relaxation were measured dynamically. Each specimen received one, two, or three sequential laser exposures (average irradiation times of 5, 6, and 8 seconds). The cartilage reached a peak surface temperature of about 70 degrees Celsius during irradiation. Cartilage denatured in 50% EtOH (20 minutes) was used as a positive control. TPM was performed using a mode-locked 780 nm Titanium:Sapphire (Ti:Al203) beam with a, 63X, 1.2 N.A. water immersion objective (working distance of 200 mm) to detect the fluorescence emission from the chondrocytes. Images of chondrocytes were obtained at depths up to 150 microns (lateral resolution equals 35 micrometer X 35 micrometer). Images were obtained immediately following laser exposure, and also after 4 days in culture. In both cases, the irradiated and non-irradiated specimens do not show any discernible difference in general shape or auto fluorescence. In contrast, positive controls (immersed in 50% ethanol), show markedly increased fluorescence relative to both the native and irradiated specimens, in the cytoplasmic region.
Passive optical limiting studies of nanostructured Cu doped ZnO-PVA composite thin films
NASA Astrophysics Data System (ADS)
Tamgadge, Y. S.; Sunatkari, A. L.; Talwatkar, S. S.; Pahurkar, V. G.; Muley, G. G.
2016-01-01
We prepared undoped and Cu doped ZnO semiconducting nanoparticles (NPs) by chemical co-precipitation method and obtained Cu doped ZnO-polyvinyl alcohol (PVA) nanocomposite thin films by spin coating to investigate third order nonlinear optical and optical limiting properties under cw laser excitation. Powder samples of NPs were characterized by X-ray diffraction (XRD), field emission scanning electron microscopy (FE-SEM), energy dispersive spectroscopy, transmission electron microscopy, ultraviolet-visible (UV-vis) and Fourier transform infrared spectroscopy. XRD pattern and FE-SEM micrograph revealed the presence of hexagonal wurtzite phase ZnO NPs having uniform morphology with average particle size of 20 nm. The presence of excitons and absorption peaks in the range 343-360 nm, revealed by UV-vis study, were attributed to excitons in n = 1 quantum state. Third order NLO properties of all composite thin films were investigated by He-Ne continuous wave (cw) laser of wavelength 632.8 nm using Z-scan technique. Thermally stimulated enhanced values of nonlinear refraction and absorption coefficients were obtained which may be attributed to self-defocusing effect, reverse saturable absorption, weak free carrier absorption and surface states properties originated from thermo optic effect. Optical limiting properties have been studied using cw diode laser of wavelength 808 nm and results are presented.
NASA Astrophysics Data System (ADS)
Pisula, K.; Gaszynski, W.; Piotrowski, D.
1996-03-01
In this paper the authors present an unconventional method of intravenous laser therapy applied to nine patients treated in ICU for acute respiratory insufficiency. The laser therapy treatment was applied twice in 24 hours by introducing a quartz light pipe into a peripheral vein of the forearm connected to the He-Ne laser produced by Amber, Poland. In order to irradiate the whole circulating blood the procedure lasted twenty minutes. The initial observation showed the improvement of the respiratory parameters and the decrease of leucocytosis. During the intravenous laser therapy the ARDS was not observed in the patients, despite the existence of risk factors.
Caltech water-ice dusty plasma: preliminary results
NASA Astrophysics Data System (ADS)
Bellan, Paul; Chai, Kilbyoung
2013-10-01
A water-ice dusty plasma laboratory experiment has begun operation at Caltech. As in Ref., a 1-5 watt parallel-plate 13.56 MHz rf discharge plasma has LN2-cooled electrodes that cool the neutral background gas to cryogenic temperatures. However, instead of creating water vapor by in-situ deuterium-oxygen bonding, here the neutral gas is argon and water vapor is added in a controlled fashion. Ice grains spontaneously form after a few seconds. Photography with a HeNe line filter of a sheet of HeNe laser light sheet illuminating a cross section of dust grains shows a large scale whorl pattern composed of concentric sub-whorls having wave-like spatially varying intensity. Each sub-whorl is composed of very evenly separated fine-scale stream-lines indicating that the ice grains move in self-organized lanes like automobiles on a multi-line highway. HeNe laser extinction together with an estimate of dust density from the intergrain spacing in photographs indicates a 5 micron nominal dust grain radius. HeNe laser diffraction patterns indicate the ice dust grains are large and ellipsoidal at low pressure (200 mT) but small and spheroidal at high pressure (>600 mT). Supported by USDOE.
The effect of ILLLI on peripheral blood SOD, MDA in psoriasis treatment
NASA Astrophysics Data System (ADS)
Zhu, Jing; Nie, Fan
2005-07-01
Objective: To research the effect of Intravascular low level laser irradiation (ILLLI) on the SOD,MDA in the treatment of psoriasis. Method :47 patients suffering from psoriasis from five groups were treated by Intravascular low level laser irradiation (power:4-5mw,1h per day, period of treatment: 10 days) .We checked the change of SOD,MDA peripheral blood in 10 normal people between pre and post treatment. Group A were treated by He-Ne laser combined with drug, group B were treated by semi-conductor laser combined with drug, group C were treated only by He-Ne laser, group D were treated only by semiconductor laser, group E were treated only by drug . Results: The levels of SOD in red cell of psoriatic patients from five groups after treatment were significantly lower than that of controlled group. The levels of SOD of them were significantly increased and nearly closed to that of controlled group; the levels of MDA in red cell of psoriatic patients from five groups after treatment were significantly higher than that of controlled group; the levels of MDA of them are decreased ,however, they were still not recovered to normal levels. Conclusions: ILLLI, both He-Ne laser and semiconductor laser, can activate SOD in psoriasis patients and enhance their ability of anti-oxidation.
Circumcision using CO2 laser: report of 860 cases
NASA Astrophysics Data System (ADS)
Chen, Wen B.; Chen, Zi-Fu; Zhan, Tian-qi; Gao, Xiang-Xun; Huang, Chao
1993-03-01
Eight-hundred-sixty cases of circumcision using CO2 laser are reported. The age of patients ranged from 9 - 65 years, with a mean age of 23.8 years. The technique was simple and can be quickly accomplished by a single operator. After local anesthesia the glans penis was protected by a protector. Then, circumcision was performed with a CO2 laser -- HeNe laser combined machine. There was an HeNe laser aiming system in this machine thus the surgeon had a three-dimensional visible indicator of the incision. The focusing CO2 laser beam was used for cutting the prepuce during the operation. There was almost no operative bleeding. All the patients needed no antibiotic postoperatively. Complications were minimal and satisfactory results were achieved.
In vitro double-integrating-sphere optical properties of tissues between 630 and 1064 nm
NASA Astrophysics Data System (ADS)
Beek, J. F.; Blokland, P.; Posthumus, P.; Aalders, M.; Pickering, J. W.; Sterenborg, H. J. C. M.; van Gemert, M. J. C.
1997-11-01
The optical properties (absorption and scattering coefficients and the scattering anisotropy factor) were measured in vitro for cartilage, liver, lung, muscle, myocardium, skin, and tumour (colon adenocarcinoma CC 531) at 630, 632.8, 790, 850 and 1064 nm. Rabbits, rats, piglets, goats, and dogs were used to obtain the tissues. A double-integrating-sphere setup with an intervening sample was used to determine the reflectance, and the diffuse and collimated transmittances of the sample. The inverse adding - doubling algorithm was used to determine the optical properties from the measurements. The overall results were comparable to those available in the literature, although only limited data are available at 790 - 850 nm. The results were reproducible for a specific sample at a specific wavelength. However, when comparing the results of different samples of the same tissue or different lasers with approximately the same wavelength (e.g. argon dye laser at 630 nm and HeNe laser at 632.8 nm) variations are large. We believe these variations in optical properties should be explained by biological variations of the tissues. In conclusion, we report on an extensive set of in vitro absorption and scattering properties of tissues measured with the same equipment and software, and by the same group. Although the accuracy of the method requires further improvement, it is highly likely that the other existing data in the literature have a similar level of accuracy.
Development of very compact soft X-ray lasers
NASA Astrophysics Data System (ADS)
Korobkin, Dmitriy Vladlenovich
1999-10-01
A powerful subpicosecond laser system, based on solid state (Ti:Al 2O3) front end and gas excimer (KrF*) amplifiers, has been developed. It is capable of producing 40-50 mJ pulses at 248 nm (285 fs pulse duration) with 2 Hz repetition rate. That radiation can be focused to intensities greater than 1017 W/cm2 and cause the optical field ionization of lithium. The system was used in experiments on gain generation in hydrogen-like Li III. Lasing action in hydrogen-like Li III 2-1 transition to ground state (13.5 nm) has been demonstrated for the first time. Gain G = 11 cm-1 in 5-mm long plasma column, created in LiF microcapillary, was measured. The observed gain-length product was GL = 5.5. In another set of experiments an inversion population between levels n = 3 and n = 2 in hydrogen-like BV was created using a low-energy compact laser system at 1 Hz repetition rate. Gain G = 17 cm-1 at 26.2 nm was measured in 3 mm long B2O3 microcapillary, which corresponds to GL = 5.1. The entire experimental setup can be fit on a single medium size optical table. Also propagation of laser radiation through plasma, created in microcapillaries has been investigated at various experimental conditions. Real-time plasma probing with low intensity HeNe laser beam has been performed.
NASA Astrophysics Data System (ADS)
Proskurnin, M. A.; Korte, D.; Rogova, O. B.; Volkov, D. S.; Franko, M.
2018-07-01
Photothermal beam deflection spectroscopy (BDS) with a red He-Ne laser (632.8 nm, 35 mW) as an excitation beam source and a green He-Ne laser (543.1 nm, 2 mW) as a probe was used for estimating thermal diffusivity of several types of soil samples and individual soil aggregates with small surfaces (2 × 2 mm). It is shown that BDS can be used on demand for studies of changes in properties of soil entities of different hierarchical levels under the action of agrogenesis. It is presented that BDS clearly distinguishes between thermal diffusivities of different soil types: Sod-podzolic [Umbric Albeluvisols, Abruptic], 29 ± 3; Chernozem typical [Voronic Chernozems, Pachic], 9.9 ± 0.9; and Light Chestnut [Haplic Kastanozems, Chromic], 9.7 ± 0.9 cm2·h-1. Aggregates of chernozem soil show a significantly higher thermal diffusivity compared to the bulk soil. Thermal diffusivities of aggregates of Chernozem for virgin and bare fallow samples differ, 53 ± 4 cm2·h-1 and 45 ± 4 cm2·h-1, respectively. Micromonoliths of different Sod-podzolic soil horizons within the same profile (topsoil, depth 10-14 cm, and a parent rock with Fe illuviation, depth 180-185 cm) also show a significant difference, thermal diffusivities are 9.5 ± 0.8 cm2·h-1 and 27 ± 2 cm2·h-1, respectively. For soil micromonoliths, BDS is capable to distinguish the difference in thermal diffusivity resulting from the changes in the structure of aggregates.
Benefits of low-power lasers on oral soft tissue
NASA Astrophysics Data System (ADS)
Eduardo, Carlos d. P.; Cecchini, Silvia C. M.; Cecchini, Renata C.
1996-04-01
The last five years have represented a great advance in relation to laser development. Countries like Japan, United States, French, England, Israel and others, have been working on the association of researches and clinical applications, in the field of laser. Low power lasers like He-Ne laser, emitting at 632,8 nm and Ga-As-Al laser, at 790 nm, have been detached acting not only as a coadjutant but some times as an specific treatment. Low power lasers provide non thermal effect at wavelengths believed to stimulate circulation and cellular activity. These lasers have been used to promote wound healing and reduce inflammation edema and pain. This work presents a five year clinical study with good results related to oral tissue healing. Oral cavity lesions, like herpes and aphthous ulcers were irradiated with Ga-Al- As laser. In both cases, an excellent result was obtained. The low power laser application decrease the painful sintomatology immediately and increase the reparation process of these lesions. An excellent result was obtained with application of low power laser in herpetic lesions associated with a secondary infection situated at the lip commissure covering the internal tissue of the mouth. The healing occurred after one week. An association of Ga-Al-As laser and Nd:YAG laser have been also proven to be good therapy for these kind of lesions. This association of low and high power laser has been done since 1992 and it seems to be a complement of the conventional therapies.
Phase control of a Zeeman-split He-Ne gas laser by variation of the gaseous discharge voltage.
Shelton, W N; Hunt, R H
1992-07-20
Zeeman-split lasers are useful for precise positioning or motion control. In applications that employ such a laser to control closely the position of a moving system, phase noise in the Zeeman frequency is a serious problem. Control of low-frequency phase noise can be obtained through variation of the external magnetic field by way of a solenoid wound around the laser tube. It is the finding in this work that control of the residual higher-frequency noise of a He-Ne laser can be obtained through small variations of the high voltage that is used to effect the gaseous discharge in the laser tube. The application of the present system is to the control of the path difference in a Fourier-transform interferometric spectrometer.
Numerical analysis of fundamental mode selection of a He-Ne laser by a circular aperture
NASA Astrophysics Data System (ADS)
He, Xin; Zhang, Bin
2011-11-01
In the He-Ne laser with an integrated cavity made of zerodur, the inner face performance of the gain tube is limited by the machining techniques, which tends to influence the beam propagation and transverse mode distribution. In order to improve the beam quality and select out the fundamental mode, an aperture is usually introduced in the cavity. In the process of laser design, the Fresnel-Kirchhoff diffraction integral equation is adopted to calculate the optical field distributions on each interface. The transit matrix is obtained based on self-reproducing principle and finite element method. Thus, optical field distribution on any interface and field loss of each transverse mode could be acquired by solving the eigenvalue and eigenvector of the transit matrix. For different-sized apertures in different positions, we could get different matrices and corresponding calculation results. By comparing these results, the optimal size and position of the aperture could be obtained. As a result, the feasibility of selecting fundamental mode in a zerodur He-Ne laser by a circular aperture has been verified theoretically.
NASA Astrophysics Data System (ADS)
Brill, Gregory E.; Dobrovolsky, Gennady A.; Romanova, Tatyana P.; Porozova, Svetlana G.; Brill, Alexander G.
1997-06-01
In experiments on white male rats short-term immobilization- sound stress was modelled. Decrease of glycogen content and myeloperoxidase activity, increase of lysosomal cationic proteins level and NBT-test parameters as well as fall of adrenaline, dopamine and 5-hydroxytryptamine amount in polymorphonuclear leukocytes were observed. Preliminary transcutaneous He-Ne laser irradiation modified metabolic reaction of leukocytes to stress and prevented stress- induced decrease of biogenic amines content in cells.
He-Ne laser treatment on menorrhagia
NASA Astrophysics Data System (ADS)
Ding, Ai-Hua
1993-03-01
By using He-Ne laser treatment, 84.7 - 91.1% of patients with menorrhagia, a common symptom of multiple gynecological diseases, are treated effectively. After laser irradiation, the amount of vaginal bleeding was reduced 47.1% on average. It has been proven that low-energy laser is an effective non-traumatic, painless, and easily acceptable new physical method in patients with menorrhagia. To study the mechanisms of efficiency, the quantitative determination of PGE2, PGF2(alpha ), 6-Keto-PGF1(alpha ), TXB2 in endometrium and blood flow before and after treatment were carried out. The results suggest that the effectiveness may be due to the recovery regulation of local uterine PGS level.
NASA Technical Reports Server (NTRS)
Abdeldayem, Hossin; Frazier, Donald O.; Penn, Benjamin; Paley, Mark S.
2003-01-01
Recently, we developed two ultra-fast all-optical switches in the nanosecond and picosecond regimes. The picosecond switch is made of a polydiacetylene thin film coated on the interior wall of a hollow capillary of approximately 50 micron diameter by a photo-polymerization process. In the setup a picosecond Nd:YAG laser at 10 Hz and at 532 nm with a pulse duration of approximately 40 ps was sent collinearly along a cw He-Ne laser beam and both were waveguided through the hollow capillary. The setup functioned as an Exclusive OR gate. On the other hand, the material used in the nanosecond switch is a phthalocyanine thin film, deposited on a glass substrate by a vapor deposition technique. In the setup a nanosecond, 10 Hz, Nd:YAG laser of 8 ns pulse duration was sent collinearly along a cw He-Ne laser beam and both were wave-guided through the phthalocyanine thin film. The setup in this case functioned as an all-optical AND logic gate. The characteristic table of the ExOR gate in polydiacetylene film was attributed to an excited state absorption process, while that of the AND gate was attributed to a saturation process of the first excited state. Both mechanisms were thoroughly investigated theoretically and found to agree remarkably well with the experimental results. An all-optical inverter gate has been designed but has not yet been demonstrated. The combination of all these three gates form the foundation for building all the necessary gates needed to build a prototype of an all-optical system.
Changes in the germination process and growth of pea in effect of laser seed irradiation
NASA Astrophysics Data System (ADS)
Podleśna, Anna; Gładyszewska, Bożena; Podleśny, Janusz; Zgrajka, Wojciech
2015-10-01
The aim of this study was to determine the effect of pre-sowing helium-neon (He-Ne) laser irradiation of pea seeds on changes in seed biochemical processes, germination rate, seedling emergence, growth rate, and yield. The first experimental factor was exposure to laser radiation: D0 - no irradiation, D3 - three exposures, D5 - five exposures, and the harvest dates were the second factor. Pre-sowing treatment of pea seeds with He-Ne laser light increased the concentrations of amylolytic enzymes and the content of indole-3-acetic acid (IAA) in pea seeds and seedlings. The exposure of seeds to He-Ne laser light improved the germination rate and uniformity and modified growth stages, which caused acceleration of flowering and ripening of pea plants. Laser light stimulation improved the morphological characteristics of plants by increasing plant height and leaf surface area. Irradiation improved the yield of vegetative and reproductive organs of pea, although the effects varied at the different growth stages. The increase in the seed yield resulted from a higher number of pods and seeds per plant, whereas no significant changes were observed in the number of seeds per pod. Both radiation doses exerted similarly stimulating effects on pea growth, development, and yield.
Low-energy laser treatment of rheumatic diseases: a long-term study
NASA Astrophysics Data System (ADS)
Antipa, Ciprian; Moldoveanu, Vladimir; Rusca, Nicolae; Bruckner, Ion I.; Podoleanu, Adrian Gh.; Stanciulescu, Viorica
1995-05-01
We tried to establish the efficiency of low energy (power) lasers (LEL), in various inflammatory and noninflammatory rheumatic diseases during five years. We treated 514 patients with osteoarthrosis, 326 patients with nonarticular rheumatism and 82 patients with inflammatory rheumatism, in four different ways: only with Galium-Aluminum-Arsenide (GaAs) infrared lasers; both GaAs lasers and Helium neon (HeNe) lasers; with placebo laser; with classical anti-inflammatory therapy. The results were analyzed using local objective improvements and the score obtained from a pain scale before and after the treatments. We also note some preliminary results obtained by the computer analysis of the evocated potentials after laser irradiation. We conclude that LEL (especially HeNe with GaAs) is obviously more efficient than placebo laser therapy and also had better or at least similar results, in most of the cases, than classical anti-inflammatory therapy.
NASA Astrophysics Data System (ADS)
Masychev, Victor I.
2000-11-01
In this research we present the results of approbation of two methods of optical caries diagnostics: PNC-spectral diagnostics and caries detection by laser integral fluorescence. The research was conducted in a dental clinic. PNC-method analyses parameters of probing laser radiation and PNC-spectrums of stimulated secondary radiations: backscattering and endogenous fluorescence of caries-involved bacterias. He-Ne-laser ((lambda) =632,8 nm, 1-2mW) was used as a source of probing (stimulated) radiation. For registration of signals, received from intact and pathological teeth PDA-detector was applied. PNC-spectrums were processed by special algorithms, and were displayed on PC monitor. The method of laser integral fluorescence was used for comparison. In this case integral power of fluorescence of human teeth was measured. As a source of probing (stimulated) radiation diode lasers ((lambda) =655 nm, 0.1 mW and 630nm, 1mW) and He-Ne laser were applied. For registration of signals Si-photodetector was used. Integral power was shown in a digital indicator. Advantages and disadvantages of these methods are described in this research. It is disclosed that the method of laser integral power of fluorescence has the following characteristics: simplicity of construction and schema-technical decisions. However the method of PNC-spectral diagnostics are characterized by considerably more sensitivity in diagnostics of initial caries and capability to differentiate pathologies of various stages (for example, calculus/initial caries). Estimation of spectral characteristics of PNC-signals allows eliminating a number of drawbacks, which are character for detection by method of laser integral fluorescence (for instance, detection of fluorescent fillings, plagues, calculus, discolorations generally, amalgam, gold fillings as if it were caries.
Remote-sensing vibrometry at 1550 nm wavelength
NASA Astrophysics Data System (ADS)
Dräbenstedt, A.; Sauer, J.; Rembe, C.
2012-06-01
Laser-Doppler vibrometry (LDV) is a proven technique for vibration analysis of mechanical structures. A wavelength of 633 nm is usually employed because of the availability of the relatively inexpensive Helium-Neon laser source which has a good coherence behavior. However, coherence break-down through the beat of multiple longitudinal modes and the limited detector carrier-to-noise-ratio (CNR) at a measurement laser power of 1 mW have prevented a wide use of LDV in remote sensing applications. Such applications in civil engineering are bridges, towers or wind turbines. The lower photon energy of IR light at 1550 nm wavelength increases the CNR by a factor 2.4. This helps especially in the condition where the carrier power decreases below the FM threshold. We have designed a heterodyne interferometer which allows the shot noise limited detection at 1550 nm wavelength close to the theoretical possible CNR. We present calculations of the fundamental noise contributions in interferometric light detection for a comparison of the achievable CNR between common HeNe vibrometers and IR vibrometers. The calculations are backed by measurements that show the devices working close to the theoretical limits. The achievable noise level of the demodulated velocity signal is shown in dependence from the standoff distance. Our novel heterodyne interferometer has been transferred to the Polytec product RSV-150. An application example of this new sensor will be demonstrated.
Photodynamic-induced inactivation of Propionibacterium acnes
NASA Astrophysics Data System (ADS)
Koenig, Karsten; Teschke, M.; Eick, Stephen G.; Pfister, W.; Meyer, Herbert; Halbhuber, Karl-Juergen
1998-05-01
We report on photodynamically induced inactivation of the skin bacterium Propionibacterium acnes (P. acnes) using endogenous as well as exogenous photosensitizers and red light sources. P. acnes is involved in the pathogenesis of the skin disease acne vulgaris. The skin bacterium is able to synthesize the metal-free fluorescent porphyrins protoporphyrin IX (PP) and coproporphyrin (CP) as shown by in situ spectrally-resolved detection of natural autofluorescence of human skin and bacteria colonies. These naturally occurring intracellular porphyrins act as efficient endogenous photosensitizers. Inactivation of P. acnes suspensions was achieved by irradiation with He-Ne laser light in the red spectral region (632.8 nm). We monitored the photodynamically-induced death of single bacteria using a fluorescent viability kit in combination with confocal laser scanning microscopy. In addition, the photo-induced inactivation was calculated by CFU (colony forming units) determination. We found 633 nm-induced inactivation (60 mW, 0.12 cm2 exposure area, 1 hour irradiation) of 72% in the case of non-incubated bacteria based on the destructive effect of singlet oxygen produced by red light excited endogenous porphyrins and subsequent energy transfer to molecular oxygen. In order to achieve a nearly complete inactivation within one exposure procedure, the exogenous photosensitizer Methylene Blue (Mb) was added. Far red exposure of Mb-labeled bacteria using a krypton ion laser at 647 nm and 676 nm resulted in 99% inactivation.
Nonlinear optical measurements of conducting copolymers of aniline under CW laser excitation
NASA Astrophysics Data System (ADS)
Pramodini, S.; Poornesh, P.
2015-08-01
Synthesis and measurements of third-order optical nonlinearity and optical limiting of conducting copolymers of aniline are presented. Single beam z-scan technique was employed for the nonlinear optical studies. Continuous wave He-Ne laser operating at 633 nm was used as the source of excitation. Copolymer samples exhibited reverse saturable absorption (RSA) process. The nonlinear refraction studies depict that the copolymers exhibit self-defocusing property. The estimated values of βeff, n2 and χ(3) were found to be of the order of 10-2 cm/W, 10-5 esu and 10-7 esu respectively. Self-diffraction rings were observed due to refractive index change when exposed to the laser beam. A good optical limiting and clamping of power of ∼0.9 mW and ∼0.05 mW was observed. Therefore, copolymers of aniline emerge as a potential candidate for photonic device applications.
Hadjichristov, Georgi B; Marinov, Yordan G; Petrov, Alexander G
2011-06-01
The light modulating ability of gradient polymer-disposed liquid crystal (PDLC) single layer of large droplets formed by nematic E7 in UV-cured polymer NOA65 is studied. Operating at relatively low voltages, such PDLC film with a of thickness 10-25 μm and droplet size up to 50 μm exhibits a good contrast ratio and is capable of producing a large phase shift for the propagating coherent light. For a linearly polarized He-Ne laser (λ=633 nm), an electrically commanded phase shift as large as π/2 can be obtained by the large-droplet region of the film. The electrically produced phase shift and its spatial profile controlled by the thickness of the gradient PDLC single layers of large nematic droplets can be useful for tunable spatial light modulators and other devices for active control of laser light.
Measurement technology based on laser internal/external cavity tuning
NASA Astrophysics Data System (ADS)
Zhang, Shulian
2011-08-01
For an ordinary laser with two cavity mirrors, if the length of laser cavity changes half wavelength the laser frequency changes one longitudinal mode separation. For a laser with three cavity mirrors, in which a feedback mirror is used to feed part of the laser output beam back into the laser cavity, the external cavity length changes half wavelength the laser intensity fluctuates one period. This presentation gives some research results in measurement field based on changing (tuning) the length of laser internal/external cavity, including 1) HeNe laser cavity-tuning nanometer displacement measurement instruments (laser nanometer rulers), 2) HeNe laser feedback displacement measurement, 3) Nd:YAG laser feedback nanometer displacement measurement, 4) benchmark of waveplate phase retardation measurement based on laser frequency splitting, 5) in-site waveplate phase retardation measurement instruments based on laser feedback and polarization hopping, 6) quasi-common-path microchip Nd:YAG laser feedback interferometer, 7) non-contact Nd:YAG laser feedback surface profile measurement. Some of these instruments have been put into application and display some irreplaceable advantages.
Thermal effects in laser-assisted embryo hatching
NASA Astrophysics Data System (ADS)
Douglas-Hamilton, Diarmaid H.; Conia, Jerome D.
2000-08-01
Diode lasers [(lambda) equals 1480 nm] are used with in-vitro fertilization [IVF] as a promoter of embryo hatching. A focused laser beam is applied in vitro to form a channel in the zona pellucida (shell) of the pre-embryo. After transfer into the uterus, the embryo hatches: it extrudes itself through the channel and implants into the uterine wall. Laser-assisted hatching can result in improving implantation and pregnancy success rates. We present examples of zone pellucida ablation using animal models. In using the laser it is vital not to damage pre-embryo cells, e.g. by overheating. In order to define safe regimes we have derived some thermal side-effects of zona pellucida removal. The temperature profile in the beam and vicinity is predicted as function of laser pulse duration and power. In a crossed-beam experiment a HeNe laser probe detects the temperature-induced change in refractive index. We find that the diode laser beam produces superheated water approaching 200 C on the beam axis. Thermal histories during and following the laser pulse are given for regions in the neighborhood of the beam. We conclude that an optimum regime exists with pulse duration
NASA Astrophysics Data System (ADS)
Dixit, S. K.
The field of gas lasers, started with the invention of He-Ne laser in 1961, has witnessed tremendous growth in terms of technology development, research into gaseous gain medium, resonator physics and application in widely diverse arenas. This was possible due to high versatility of gas lasers in terms of operating wavelengths, power, beam quality and mode of operation. In recent years, there is a definite trend to replace the gas lasers, wherever possible, by more efficient and compact solid-state lasers. However, for many industrial, medical and military applications, the gas lasers still rule the roost due to their high-power capabilities with good beam quality at specific wavelengths. This chapter presents a short review covering the operating principle, important technical details and application potential of all the important gas lasers such as He-Ne, CO2, argon ion, copper vapour, excimer and chemical lasers. These neutral atoms, ions and molecule gas lasers are discussed as per applicable electrical, chemical and optical excitation schemes. The optically pumped gas lasers, recently experiencing resurgence, are discussed in the context of far infrared THz molecular lasers, diode-pumped alkali lasers and optically pumped gas-filled hollow-core fibre lasers.
Study of working principle and thermal balance process of a double longitudinal-mode He-Ne laser
NASA Astrophysics Data System (ADS)
Wang, Li-qiang
2009-07-01
A double longitudinal mode He-Ne laser with frequency stabilization is proposed. Compared with general methods, such as Lamb dip, Zeeman splitting and molecule saturation absorption method, this design has some advantages, such as no piezocrystal or magnetic field, a short frequency-stabilized time, lower cost, and higher frequency stability and reproducibility. The metal wire is uniformly wrapped on the discharge tube of the laser. When the metal wire is heated up, the resonant cavity changes with the temperature field around the discharge tube to make the frequency of the laser to be tuned. The polarizations of the two longitudinal modes from the laser must be orthogonal. The parallelly polarized light and the vertically polarized light compete with each other, i. e., the parallelly polarized light generates a larger output power, while, the vertically polarized light correspondingly generates a smaller one, but an equal value is found at the reference frequencies by automatically adjusting the length of the resonant cavity, due to change of the temperature in the discharge tube. Consequently the frequencies of the laser are stabilized. In my experiment, an intracavity He-Ne laser whose length of the resonant cavity is larger than 50mm and smaller than 300mm is selected for the double longitudinal-mode laser. Influence factors of frequency stability of this laser is only change of the length of the resonant cavity. The laser includes three stages: mode hopping, transition stage, and modes stability from startup to laser stability. When this laser is in modes stability, the waveform of heating metal wire is observed to a pulse whose duty is almost 50%, and thermal balances of the resonant cavity mainly rely on discharge tube.
Smith, Ryan P.; Roos, Peter A.; Wahlstrand, Jared K.; Pipis, Jessica A.; Rivas, Maria Belmonte; Cundiff, Steven T.
2007-01-01
We perform optical frequency metrology of an iodine-stabilized He-Ne laser using a mode-locked Ti:sapphire laser frequency comb that is stabilized using quantum interference of photocurrents in a semiconductor. Using this technique, we demonstrate carrier-envelope offset frequency fluctuations of less than 5 mHz using a 1 s gate time. With the resulting stable frequency comb, we measure the optical frequency of the iodine transition [127I2 R(127) 11-5 i component] to be 473 612 214 712.96 ± 0.66 kHz, well within the uncertainty of the CIPM recommended value. The stability of the quantum interference technique is high enough such that it does not limit the measurements. PMID:27110472
Thermal effects in laser-assisted pre-embryo zona drilling
NASA Astrophysics Data System (ADS)
Douglas-Hamilton, Diarmaid H.; Conia, Jerome D.
2001-04-01
Diode lasers ((lambda) equals 1480 nm) are used with in vitro fertilization to dissect the zone pellucida (shell) of pre- embryos. A focused laser beam is applied in vitro to form a channel or trench in the zona pellucida. The procedure is used to facilitate biopsy or as a promoter of embryo hatching. We present examples and measurements of zona pellucida ablation using animal models. In using the laser it is vital not to damage pre-embryo cells, e.g., by overheating. In order to define safe regimes we have derived some thermal side effects of zona pellucida removal. The temperature profile in the beam and vicinity is predicted as function of laser pulse duration and power. In a crossed- beam experiment a HeNe laser probe is used to detect the temperature-induced change in the refractive index of an aqueous solution, and estimate local thermal gradient. We find that the diode laser beam produces superheated water approaching 200 degree(s)C on the beam axis. Thermal histories during and following the laser pulse are given for regions in the neighborhood of the beam. We conclude that an optimum regime exists with pulse duration
Low-Level Light Stimulates Excisional Wound Healing in Mice
Demidova-Rice, Tatiana N.; Salomatina, Elena V.; Yaroslavsky, Anna N.; Herman, Ira M.; Hamblin, Michael R.
2010-01-01
Background Low levels of laser or non-coherent light, termed low-level light therapy (LLLT) have been reported to accelerate some phases of wound healing, but its clinical use remains controversial. Methods A full thickness dorsal excisional wound in mice was treated with a single exposure to light of various wavelengths and fluences 30 minutes after wounding. Wound areas were measured until complete healing and immunofluorescence staining of tissue samples was carried out. Results Wound healing was significantly stimulated in BALB/c and SKH1 hairless mice but not in C57BL/6 mice. Illuminated wounds started to contract while control wounds initially expanded for the first 24 hours. We found a biphasic dose–response curve for fluence of 635-nm light with a maximum positive effect at 2 J/cm2. Eight hundred twenty nanometer was found to be the best wavelength tested compared to 635, 670, and 720 nm. We found no difference between non-coherent 635 ± 15-nm light from a lamp and coherent 633-nm light from a He/Ne laser. LLLT increased the number of α-smooth muscle actin (SMA)-positive cells at the wound edge. Conclusion LLLT stimulates wound contraction in susceptible mouse strains but the mechanism remains uncertain. PMID:17960752
Laser system for natural gas detection. Phase 1: Laboratory feasibility studies
NASA Technical Reports Server (NTRS)
Grant, W. B.; Hinkley, E. D., Jr.
1982-01-01
This project demonstrated the feasibility of using laser remote sensing technology as a tool for leak survey work in natural gas distribution systems. A laboratory device was assembled using a pair of helium neon (HeNe) lasers to measure methane. One HeNe laser emits radiation at a wavelength of 3.3922 micrometers, which corresponds to a strong absorption feature of methane, while the other emits radiation at a wavelength of 3.3911 micrometers, which corresponds to a weak absorption by methane. As a particular area is scanned for leaks, the laser is pointed at convenient topographic targets within its operating range, about 25 m. A portion of the backscattered radiation is collected by a receiver and focused onto an indium antimonide (InSb) photodetector, cooled to 77K. Methane concentrations were determined from the differential absorption at the two wavelengths for the backscattered radiation.
Laser vibration sensing at Fraunhofer IOSB: review and applications
NASA Astrophysics Data System (ADS)
Lutzmann, Peter; Göhler, Benjamin; Hill, Chris A.; van Putten, Frank
2017-03-01
Laser vibrometry based on coherent detection allows noncontact measurements of small-amplitude vibration characteristics of objects. This technique, commonly using the Doppler effect, offers high potential for short-range civil applications and for medium- or long-range applications in defense and security. Most commercially available laser Doppler vibrometers are for short ranges (up to a few tens of meters) and use a single beam from a low-power HeNe laser source (λ=633 nm). Medium- or long-range applications need higher laser output power, and thus, appropriate vibrometers typically operate at 1.5, 2, or 10.6 μm to meet the laser safety regulations. Spatially resolved vibrational information can be obtained from an object by using scanning laser vibrometers. To reduce measuring time and to measure transient object movements and vibrational mode structures of objects, several approaches to multibeam laser Doppler vibrometry have been developed, and some of them are already commercially available for short ranges. We focus on applications in the field of defense and security, such as target classification and identification, including camouflaged or partly concealed targets, and the detection of buried land mines. Examples of civil medium-range applications are also given.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Gaozhong; Zhang, Saifeng, E-mail: sfzhang@siom.ac.cn, E-mail: jwang@siom.ac.cn; Cheng, Xin
2014-04-07
Spatial self-phase modulation (SSPM) was observed directly when a focused He-Ne laser beam at 633 nm went through liquid-phase-exfoliated graphene dispersions. The diffraction pattern of SSPM was found to be distorted rapidly right after the incident beam horizontally passing through the dispersions, while no distortion for the vertically incident geometry. We show that the distortion is originated mainly from the non-axis-symmetrical thermal convections of the graphene nanosheets induced by laser heating, and the relative change of nonlinear refractive index can be determined by the ratio of the distortion angle to the half-cone angle. Therefore, the effective nonlinear refractive index of graphenemore » dispersions can be tuned by changing the incident intensity and the temperature of the dispersions.« less
Detection of bacterial infection of agave plants by laser-induced fluorescence
NASA Astrophysics Data System (ADS)
Cervantes-Martinez, Jesus; Flores-Hernandez, Ricardo; Rodriguez-Garay, Benjamin; Santacruz-Ruvalcaba, Fernando
2002-05-01
Greenhouse-grown plants of Agave tequilana Weber var. azul were inoculated with Erwinia carotovora, the causal agent of stem soft rot. We investigated the laser-induced fluorescence (LIF) of agave plants to determine whether LIF can be used as a noninvasive sensing tool for pathological studies. The LIF technique was also investigated as a means of detecting the effect of the polyamine biosynthesis inhibitor beta-hydroxyethylhydrazine as a bactericide against the pathogenic bacterium Erwinia carotovora. A He-Ne laser at 632.8 nm was used as the excitation source, and in vivo fluorescence emission spectra were recorded in the 660-790-range. Fluorescence maxima were at 690 and 740 nm. The infected plants that were untreated with the bactericide showed a definite increase in fluorescence intensity at both maxima within the first three days after infection. Beginning on the fifth day, a steady decrease in fluorescence intensity was observed, with a greater effect at 740 than at 690 nm. After 30 days there was no fluorescence. The infected plants that had been treated with the bactericide showed no significant change in fluorescence compared with that of the uninfected plants. The ratio of fluorescence intensities was determined to be F 690 nm/F 740 nm for all treatments. These studies indicate that LIF measurements of agave plants may be used for the early detection of certain types of disease and for determining the effect of a bactericide on bacteria. The results also showed that fluorescence intensity ratios can be used as a reliable indicator of the progress of disease.
Detection of bacterial infection of agave plants by laser-induced fluorescence.
Cervantes-Martínez, Jesús; Flores-Hernández, Ricardo; Rodríguez-Garay, Benjamin; Santacruz-Ruvalcaba, Fernando
2002-05-01
Greenhouse-grown plants of Agave tequilana Weber var. azul were inoculated with Erwinia carotovora, the causal agent of stem soft rot. We investigated the laser-induced fluorescence (LIF) of agave plants to determine whether LIF can be used as a noninvasive sensing tool for pathological studies. The LIF technique was also investigated as a means of detecting the effect of the polyamine biosynthesis inhibitor beta-hydroxyethylhydrazine as a bactericide against the pathogenic bacterium Erwinia carotovora. A He-Ne laser at 632.8 nm was used as the excitation source, and in vivo fluorescence emission spectra were recorded in the 660-790-range. Fluorescence maxima were at 690 and 740 nm. The infected plants that were untreated with the bactericide showed a definite increase in fluorescence intensity at both maxima within the first three days after infection. Beginning on the fifth day, a steady decrease in fluorescence intensity was observed, with a greater effect at 740 than at 690 nm. After 30 days there was no fluorescence. The infected plants that had been treated with the bactericide showed no significant change in fluorescence compared with that of the uninfected plants. The ratio of fluorescence intensities was determined to be F 690 nm/F 740 nm for all treatments. These studies indicate that LIF measurements of agave plants may be used for the early detection of certain types of disease and for determining the effect of a bactericide on bacteria. The results also showed that fluorescence intensity ratios can be used as a reliable indicator of the progress of disease.
NASA Astrophysics Data System (ADS)
Maliszewska, Irena; Leśniewska, Agata; Olesiak-Bańska, Joanna; Matczyszyn, Katarzyna; Samoć, Marek
2014-06-01
There is considerable current interest in photodynamic inactivation (PDI) as potential antimicrobial therapy. This study reports successful implementation of PDI of Staphylococcus epidermidis using methylene blue (MB) in combination with biogenic gold nanoparticles (GNP). Monodispersed colloidal GNP were synthesized by reduction of Au+3 in the presence of cell-free filtrate of Trichoderma koningii and were characterized by a number of techniques including UV-Vis and fluorescence spectroscopy, transmission electron microscopy (TEM), and Fourier transform infrared spectroscopy (FTIR) to be 12 ± 3 nm spherical gold particles coated with proteins. Studies on the role of the cell-free filtrate proteins in the synthesis of the GNP indicate that the process is nonenzymatic but involves interactions of various amino acids with gold ions. A Xe lamp (550-780 nm) or a He-Ne laser (632 nm) was used as light sources to study the effect of MB alone, the GNP alone, and the MB-GNP mixture on the viability of bacterial cells. Lethal photosensitization of S. epidermidis with the MB-GNP mixture was achieved after 5 and 10 min exposure to laser or Xe lamp, respectively. It has been found that the MB-GNP mixture exhibits a significant antibacterial activity already in the absence of any light source and gives an enhanced antimicrobial response when using either a laser or a Xe lamp source for photosensitization.
Measurements of Effective Schottky Barrier in Inverse Extraordinary Optoconductance Structures
NASA Astrophysics Data System (ADS)
Tran, L. C.; Werner, F. M.; Solin, S. A.; Gilbertson, Adam; Cohen, L. F.
2013-03-01
Individually addressable optical sensors with dimensions as low as 250nm, fabricated from metal semiconductor hybrid structures (MSH) of AuTi-GaAs Schottky interfaces, display a transition from resistance decreasing with intensity in micron-scale sensors (Extraordinary Optoconductance, EOC) to resistance increasing with intensity in nano-scale sensors (Inverse Extraordinary Optoconductance I-EOC). I-EOC is attributed to a ballistic to diffusive crossover with the introduction of photo-induced carriers and gives rise to resistance changes of up to 9462% in 250nm devices. We characterize the photo-dependence of the effective Schottky barrier in EOC/I-EOC structures by the open circuit voltage and reverse bias resistance. Under illumination by a 5 mW, 632.8 nm HeNe laser, the barrier is negligible and the Ti-GaAs interface becomes Ohmic. Comparing the behavior of two devices, one with leads exposed, another with leads covered by an opaque epoxy, the variation in Voc with the position of the laser can be attributed to a photovoltaic effect of the lead metal and bulk GaAs. The resistance is unaffected by the photovoltaic offset of the leads, as indicated by the radial symmetry of 2-D resistance maps obtained by rastering a laser across EOC/IEOC devices. SAS has a financial interest in PixelEXX, a start-up company whose mission is to market imaging arrays.
He-Ne and CW CO2 laser long-path systems for gas detection
NASA Technical Reports Server (NTRS)
Grant, W. B.
1986-01-01
This paper describes the design and testing of a laboratory prototype dual He-Ne laser system for the detection of methane leaks from underground pipelines and solid-waste landfill sites using differential absorption of radiation backscattered from topographic targets. A laboratory-prototype dual CW carbon dioxide laser system also using topographic backscatter is discussed, and measurement results for methanol are given. With both systems, it was observed that the time-varying differential absorption signal was useful in indicating the presence of a gas coming from a nearby source. Limitations to measurement sensitivity, especially the role of speckle and atmospheric turbulence, are described. The speckle results for hard targets are contrasted with those from atmospheric aerosols. The appendix gives appropriate laser lines and values of absorption coefficients for the hydrazine fuel gases.
Narrow-linewidth tunable laser working at 633 nm suitable for industrial interferometry
NASA Astrophysics Data System (ADS)
Minh, Tuan Pham; Hucl, Václav; Čížek, Martin; Mikel, Břetislav; Hrabina, Jan; Řeřucha, Šimon; Číp, Ondřej; Lazar, Josef
2015-05-01
Semiconductor lasers found a foothold in many fields of human activities, mainly thanks to its small size, low cost and high energy efficiency. Recent methods for accurate distance measurement in industrial practice use principles of laser interferometry, which are based on lasers operating in the visible spectrum. When the laser beam is visible the alignment of the industrial interferometer makes the measuring process easier. Traditional lasers for these purposes for many decades - HeNe gas laser - have superb coherence properties but small tunable range. On the other hand laser diodes are very useful lasers but only if the active layer of the semiconductor equips with a passive selective element that will increase the quality of their own resonator and also prevents the structure of its higher longitudinal modes. The main aim of the work is a design of the laser source based on a new commercial available laser diode with Distributed Bragg Reflector structure, butterfly package and fibre coupled output. The ultra-low noise injection current source, stable temperature controller and supply electronic equipment were developed with us and experimentally tested with this laser for the best performances required of the industrial interferometry field. The work also performs a setup for frequency noise properties investigation with an unbalanced fibre based Mach-Zehnder interferometer and 10 m long fibre spool inserted in the reference arm. The work presents the way to developing the narrow-linewidth operation the DBR laser with the wide tunable range up to more than 1 nm of the operation wavelength at the same time. Both capabilities predetermine this complex setup for the industrial interferometry application as they are the long distance surveying or absolute scale interferometry.
Santhakumari, R; Ramamurthi, K
2011-02-01
Single crystals of the organic NLO material, benzaldehyde thiosemicarbazone (BTSC) monohydrate, were grown by slow evaporation method. Solubility of BTSC monohydrate was determined in ethanol at different temperatures. The grown crystals were characterized by single crystal X-ray diffraction analysis to determine the cell parameters and by FT-IR technique to study the presence of the functional groups. Thermogravimetric and differential thermal analyses reveal the thermal stability of the crystal. UV-vis-NIR spectrum shows excellent transmission in the region of 200-1100 nm. Theoretical calculations were carried out to determine the linear optical constants such as extinction coefficient and refractive index. Further the optical nonlinearities of BTSC have been investigated by Z-scan technique with He-Ne laser radiation of wavelength 632.8 nm. Mechanical properties of the grown crystal were studied using Vickers microhardness tester. Second harmonic generation efficiency of the powdered BTSC monohydrate was tested using Nd:YAG laser and it is found to be ∼5.3 times that of potassium dihydrogen orthophosphate. Copyright © 2010 Elsevier B.V. All rights reserved.
Laser Ablation of Biological Tissue Using Pulsed CO{sub 2} Laser
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hashishin, Yuichi; Sano, Shu; Nakayama, Takeyoshi
2010-10-13
Laser scalpels are currently used as a form of laser treatment. However, their ablation mechanism has not been clarified because laser excision of biological tissue occurs over a short time scale. Biological tissue ablation generates sound (laser-induced sound). This study seeks to clarify the ablation mechanism. The state of the gelatin ablation was determined using a high-speed video camera and the power reduction of a He-Ne laser beam. The aim of this study was to clarify the laser ablation mechanism by observing laser excision using the high-speed video camera and monitoring the power reduction of the He-Ne laser beam. Wemore » simulated laser excision of a biological tissue by irradiating gelatin (10 wt%) with radiation from a pulsed CO{sub 2} laser (wavelength: 10.6 {mu}m; pulse width: 80 ns). In addition, a microphone was used to measure the laser-induced sound. The first pulse caused ablation particles to be emitted in all directions; these particles were subsequently damped so that they formed a mushroom cloud. Furthermore, water was initially evaporated by laser irradiation and then tissue was ejected.« less
IR and He-Ne laser in the treatment of wounds and painful disorders in horses and in dogs
NASA Astrophysics Data System (ADS)
Canavesio, Ermes; Casiraghi, Emanuela; Codazza, Danilo
1996-05-01
To evaluate the therapeutic applications of laser, 3 dogs and 26 horses were selected for the treatment of skin lesions, and 1 dog and 16 horses for analgesic treatment. The equipment used consisted of either red or infrared light laser apparatuses modified in order to increase the manageability and the power of the instrument. It was observed that He-Ne laser allowed a more rapid restitutio ad integrum with a lesser amount of J/cm2 and so apparatuses were advantageous for the treatment of fistolous tracts complicated by abscess formation. In fact, by using sterilizable optical fibers, it was possible to reach the deeper parts of the tract. When considering the rapidity of the healing process of different body areas, the withers seems to necessitate the longest period of time to recover. Infrared laser is best used for pain relief and satisfactory results were observed without resting the animals. Significant and beneficial effects from laser therapy are obtained after 7 - 10 days of therapy.
Atmospheric methane measurement instrument using a Zeeman-split He-Ne laser
NASA Technical Reports Server (NTRS)
Mcmanus, J. Barry; Kebabian, Paul L.; Kolb, Charles E.
1989-01-01
The construction of an atmospheric methane measurement instrument based on a Zeeman-split IR He-Ne laser is reported. The laser has a tranverse magnetic field over about 2/3 of its gain length and can oscillate at an (unsplit) frequency (2947.91/cm) centered on a methane absorption line, or on either of two frequencies split by + or - 0.055/cm from the center, with low CH4 absorption. The laser is tuned to dwell sequentially at each frequency, giving two differential absorption measurements in each 46-ms tuning cycle. Atmospheric measurements are made using two multiple pass absorption cells, one with fast (0.75-s) and one with slow (5-s) flow response times. Fluctuations in ambient CH4 of about 20-ppb (rms, 1-s averaging) are detected, with interference fringe effects the dominant noise source. The instrument has operated in a field experiment (NASA GTE/ABLE-3A) in Alaska.
NASA Astrophysics Data System (ADS)
Yang, Bo; Wang, Dehui; Zhou, Lin; Wu, Shuang; Xiang, Rong; Zhang, Wenhua; Gui, Huaqiao; Liu, Jianguo; Wang, Huanqing; Lu, Liang; Yu, Benli
2017-06-01
The self-mixing technique based on the traditional reflecting mirror has been demonstrated with great merit for angle sensing applications. Here we demonstrate a modified self-reflection-mixing angle measurement system by combine a right-angle prism to self-mixing angle measurement. In our system, the wavelength is crucial to the angle measurement resolution. For a microchip solid-state laser, the measurement resolution can reach 0.49 mrad, while the resolution for the He-Ne laser is 0.53 mrad. In addition, the ranges in the system with the microchip solid-state laser and He-Ne laser are up to 22 mrad and 24.9 mrad respectively. This modified angle measurement system effectively combines the advantage of self-mixing measurement system with a compact structure, providing interesting features such as of high requisition of resolution and precision.
NASA Astrophysics Data System (ADS)
Hall, John L.
2010-02-01
Michelson's 1907 proposal to define the SI Metre in terms of an optical wavelength was realized only in 1960, based on a ^86Krypton discharge lamp. The same year saw the cw HeNe laser arrive and a future redefinition based on laser technology assured. Separation in the late 60's of the laser's gain and spectral-reference-gas functions led to unprecedented levels of laser frequency stability and reproducibility. In addition to HeNe:CH4 system at 3392 nm and HeNe:I2 at 633 nm, systems at 514 nm and 10600 nm were studied. Absolute frequency measurement became the holy grail and some NBS team experiences will be shared. We measured both frequency and wavelength in 1972, and so obtained a speed of light value, improved 100-fold in accuracy. During the next decade, the NBS value of c was confirmed by other national labs, and frequency metrology was extended to the 473 THz (633 nm) Iodine-based wavelength standard. This frequency to ˜10 digit accuracy was obtained in 1983, thus setting the stage for redefining the SI Metre. By consensus choice the value 299 792 458 m/s was adopted for the speed of light, effectively reducing the Metre to a derived SI quantity. Knowledge of the frequency of the particular laser being utilized was controlled by International intercomparisons, but the need for a fast and accurate means to make these laser frequency measurements was obvious. Creative proposals by H"ansch and by Chebotayev were to use ultra-fast repetitive pulses to create an ``Optical Comb,'' but it was years before any technical basis existed to implement their Fourier dreams. Finally, in 1999 the last needed capability was demonstrated -- continuum production at 100 MHz rates and non-destructive power levels. By May 2000 phase-locked combs were operational in both Garching and Boulder, substantially accelerated by their collaborative interactions. Within 18 months all the known proposed ``optical frequency standards'' had been accurately measured via Comb techniques. )
1992-01-01
Bridgman method VI - with (VBZ) and without (VB) a cadmium source can be 1- observed. In VB crystals grown from a slightly tellurium-rich melt the axial...CdTe epilayers will be performed ex 3. Results situ. Light sources are, respectively, a low power HeNe laser emitting at 633 nm and a 75 W xenon lamp for...Positrons can be used as a probe of vacancy-type recorded about 2 x 106 annihilations. After source and defects in semiconductors by studying their
Wang, Guochao; Tan, Lilong; Yan, Shuhua
2018-02-07
We report on a frequency-comb-referenced absolute interferometer which instantly measures long distance by integrating multi-wavelength interferometry with direct synthetic wavelength interferometry. The reported interferometer utilizes four different wavelengths, simultaneously calibrated to the frequency comb of a femtosecond laser, to implement subwavelength distance measurement, while direct synthetic wavelength interferometry is elaborately introduced by launching a fifth wavelength to extend a non-ambiguous range for meter-scale measurement. A linearity test performed comparatively with a He-Ne laser interferometer shows a residual error of less than 70.8 nm in peak-to-valley over a 3 m distance, and a 10 h distance comparison is demonstrated to gain fractional deviations of ~3 × 10 -8 versus 3 m distance. Test results reveal that the presented absolute interferometer enables precise, stable, and long-term distance measurements and facilitates absolute positioning applications such as large-scale manufacturing and space missions.
Dynamics of laser ablative shock waves from one dimensional periodic structured surfaces
NASA Astrophysics Data System (ADS)
Paturi, Prem Kiran; Chelikani, Leela; Pinnoju, Venkateshwarlu; Acrhem Team
2015-06-01
Spatio-temporal evolution of Laser ablative shock waves (LASWs) from one dimensional periodic structured surfaces (1D-PSS) of Aluminum is studied using time resolved defocused shadowgraphy technique. LASWs are generated by focusing 7 ns pulses from second harmonic of Nd:YAG (532 nm, 10 Hz) laser on to 1D-PSS with sinusoidal and triangular modulations of varying periodicity. An expanded He-Ne laser (632.8 nm) is used as probe beam for shadowgraphy. Evolution of ablative shock front (SF) with 1.5 ns temporal resolution is used to measure position of the SF, its nature, density and pressure behind the SF. The effect of surface modulation on the LASW and contact front dynamics was compared to those from a flat surface (FS) of Aluminum. SWs from FS and PSS obeyed Taylor's solution for spherical and planar nature, respectively. The velocity of SF from 1D PSS had a twofold increase compared to the FS. This was further enhanced for structures whose periodicity is of the order of excitation wavelength. Variation of SF properties with varying periodicity over a range of 3.3 μm to 0.55 μm has the potential to tailor shockwaves of required parameters. The work is supported by Defence Research and Developement Organization, India through Grants-in-Aid Program. The periodic surfaces were procured with financial support from BRFST project No. NFP-MAT-A12-04.
Quantification of telomere length by FISH and laser scanning cytometry
NASA Astrophysics Data System (ADS)
Mahoney, John E.; Sahin, Ergun; Jaskelioff, Mariela; Chin, Lynda; DePinho, Ronald A.; Protopopov, Alexei I.
2008-02-01
Telomeres play a critical role in the maintenance of chromosomal stability. Telomere erosion, coupled with loss of DNA damage checkpoint function, results in genomic instability that promotes the development of cancer. The critical role of telomere dynamics in cancer has motivated the development of technologies designed to monitor telomere reserves in a highly quantitative and high-throughput manner in humans and model organisms. To this end, we have adapted and modified two established technologies, telomere-FISH and laser scanning cytometry. Specifically, we have produced a number of enhancements to the iCys LSC (CompuCyte) package including software updates, use of 60X dry objectives, and increased spatial resolution by 0.2 um size of stage steps. In addition, the 633 nm HeNe laser was replaced with a 532 nm green diode laser to better match the viewing options. Utilization of telomere-deficient mouse cells with short dysfunctional telomeres and matched telomerase reconstituted cultures demonstrated significantly higher mean integral specific fluorescence values for mTR transfectants relative to empty vector controls: 4.485M vs. 1.362M (p<0.0001). Histograms of average telomere intensities for individual cells were obtained and demonstrated intercellular heterogeneity in telomere lengths. The validation of the approach derives from a strong correlation between iCys LSC values and Southern blotting. This validated method greatly increases our experimental throughput and objectivity.
NASA Astrophysics Data System (ADS)
Senarathna, Janaka; Hadjiabadi, Darian; Gil, Stacy; Thakor, Nitish V.; Pathak, Arvind P.
2017-02-01
Different brain regions exhibit complex information processing even at rest. Therefore, assessing temporal correlations between regions permits task-free visualization of their `resting state connectivity'. Although functional MRI (fMRI) is widely used for mapping resting state connectivity in the human brain, it is not well suited for `microvascular scale' imaging in rodents because of its limited spatial resolution. Moreover, co-registered cerebral blood flow (CBF) and total hemoglobin (HbT) data are often unavailable in conventional fMRI experiments. Therefore, we built a customized system that combines laser speckle contrast imaging (LSCI), intrinsic optical signal (IOS) imaging and fluorescence imaging (FI) to generate multi-contrast functional connectivity maps at a spatial resolution of 10 μm. This system comprised of three illumination sources: a 632 nm HeNe laser (for LSCI), a 570 nm ± 5 nm filtered white light source (for IOS), and a 473 nm blue laser (for FI), as well as a sensitive CCD camera operating at 10 frames per second for image acquisition. The acquired data enabled visualization of changes in resting state neurophysiology at microvascular spatial scales. Moreover, concurrent mapping of CBF and HbT-based temporal correlations enabled in vivo mapping of how resting brain regions were linked in terms of their hemodynamics. Additionally, we complemented this approach by exploiting the transit times of a fluorescent tracer (Dextran-FITC) to distinguish arterial from venous perfusion. Overall, we demonstrated the feasibility of wide area mapping of resting state connectivity at microvascular resolution and created a new toolbox for interrogating neurovascular function.
A Simple Laser Teaching Aid for Transverse Mode Structure Demonstration
ERIC Educational Resources Information Center
Ren, Cheng; Zhang, Shulian
2009-01-01
A teaching aid for demonstrating the transverse mode structure in lasers is described. A novel device called "multi-dimension adjustable combined cat-eye reflector" has been constructed from easily available materials to form a He-Ne laser resonator. By finely adjusting the cat-eye, the boundary conditions of the laser cavity can be altered, which…
The neuroprotective effects of intravascular low level laser irradiation on cerebral ischemia rats
NASA Astrophysics Data System (ADS)
Qiu, Yongming; Lu, Zhaofeng; Wang, Zhongguang; Jiang, Jiyao
2005-07-01
The effects of intravascular low level laser irradiation of He-Ne on rat MCAo-induced cerebral injury were studied. The results showed that control rats (subjected to MCAo injury without laser treatment) at 7d exhibited striatal and cortical brain infarction in the right hemisphere from approximately 3 to 11mm from the front pole. the total infarct volume in this group was 34.5+/-8.1mm3. For experimental rats (with laser management), the total infarct volume was 29.0+/-9.0mm3. P was gained less than 0.05. The neurological score of control group was 4.7+/-0.6 and it was 5.2+/-1.0 in experimental group, comparison by statistical analysis showed P less than 0.05. The cerebral pathological damages in the control group were more severe than in experimental group. We concluded that the intravascular low level laser irradiation has no remarked complication and is helpful to reduce ischemic damage. There is clinically potential for the application of intravascular He-Ne low level laser irradiation in ischemia stroke.
NASA Astrophysics Data System (ADS)
dos Reis, Edmyr R.; Nicola, Ester M. D.; Metze, Konradin; Nicola, Jorge H.
2000-06-01
In rats, the Harderian Gland secret Protoporphirin IX which is retained at acinar lumina. Since this photosensitizer is important for PDT of malignant tumors, we propose to study this gland as a model to help understanding PDT with endogenous photosensitizers. Twenty Wistar SPF adult rats were submitted to surgical exposure of both Harderian glands, revealing red fluorescence upon UV, characterizing the protoporphirin IX presence. After that, one gland of each pair (one kept as control) was irradiated with an 8 mW HeNe (6328 angstrom) for 45 minutes, delivering about 2.7 joules/mm2. After 24 hours a group of 10 animals were scarified and the glands removed for histological analysis. The remaining animals were subjected to the same procedure but the glands were removed immediately after laser treatment. Histological and fluorescence analysis immediately after laser irradiation showed cell fragmentation with loss of acinar architecture with diffusion of protoporphirin in the cytoplasm of damaged cells, as well as interstitial edema. After 24 hours these alterations were more pronounced with accentuated loss of intraluminal protoporphirin and beginning of leukocytic demarcation of necrotic areas. The innate Harderian glands of rats, exposed to HeNe laser, showed a similar behavior as tumor tissue under PDT.
Expression of fas protein on CD4+T cells irradiated by low level He-Ne
NASA Astrophysics Data System (ADS)
Nie, Fan; Zhu, Jing; Zhang, Hui-Guo
2005-07-01
Objective: To investigate the influence on the Expression of Fas protein on CD4+ T cells irradiated by low level He-Ne laser in the cases of psoriasis. Methods:the expression of CD4+ T Fas protein was determined in the casee of psoriasis(n=5) pre and post-low level laser irradiation(30 min、60min and 120min)by flow cytometry as compared withthe control(n=5). Results:In the cases of psoriasis,the expression of CD4+T FAS protein 21.4+/-3.1% was increased significantly than that of control group 16.8+/-2.1% pre-irradiation, p<0.05in the control,there is no difference between pre and post- irradiation,p>0.05in the cases , the expression of CD4+T Fas protein wae positively corelated to the irradiation times, when the energy density arrived to 22.92J/cm2(60 minutes)and 45.84J/cm2(120minutes), the expression of CD4+ T Fas protein was increased significantly as compared with pre-irradiation,p<0.05.Conclusion: The expression of CD4+T Fas protein may be increased by low level He-Ne laser irradiation ,the uncontrolled status of apoptosis could be corrected.
Stanford, Michael G.; Lewis, Brett B.; Iberi, Vighter O.; ...
2016-02-16
Focused helium and neon ion (He(+)/Ne(+) ) beam processing has recently been used to push resolution limits of direct-write nanoscale synthesis. The ubiquitous insertion of focused He(+) /Ne(+) beams as the next-generation nanofabrication tool-of-choice is currently limited by deleterious subsurface and peripheral damage induced by the energetic ions in the underlying substrate. The in situ mitigation of subsurface damage induced by He(+)/Ne(+) ion exposures in silicon via a synchronized infrared pulsed laser-assisted process is demonstrated. The pulsed laser assist provides highly localized in situ photothermal energy which reduces the implantation and defect concentration by greater than 90%. The laser-assisted exposuremore » process is also shown to reduce peripheral defects in He(+) patterned graphene, which makes this process an attractive candidate for direct-write patterning of 2D materials. In conclusion, these results offer a necessary solution for the applicability of high-resolution direct-write nanoscale material processing via focused ion beams.« less
Widely tunable laser frequency offset lock with 30 GHz range and 5 THz offset.
Biesheuvel, J; Noom, D W E; Salumbides, E J; Sheridan, K T; Ubachs, W; Koelemeij, J C J
2013-06-17
We demonstrate a simple and versatile method to greatly extend the tuning range of optical frequency shifting devices, such as acousto-optic modulators (AOMs). We use this method to stabilize the frequency of a tunable narrow-band continuous-wave (CW) laser to a transmission maximum of an external Fabry-Perot interferometer (FPI) with a tunable frequency offset. This is achieved through a servo loop which contains an in-loop AOM for simple radiofrequency (RF) tuning of the optical frequency over the full 30 GHz mode-hop-free tuning range of the CW laser. By stabilizing the length of the FPI to a stabilized helium-neon (HeNe) laser (at 5 THz offset from the tunable laser) we simultaneously transfer the ~ 1 MHz absolute frequency stability of the HeNe laser to the entire 30 GHz range of the tunable laser. Thus, our method allows simple, wide-range, fast and reproducible optical frequency tuning and absolute optical frequency measurements through RF electronics, which is here demonstrated by repeatedly recording a 27-GHz-wide molecular iodine spectrum at scan rates up to 500 MHz/s. General technical aspects that determine the performance of the method are discussed in detail.
NASA Technical Reports Server (NTRS)
Grant, W. B.; Hinkley, E. D.
1984-01-01
Remote sensor uses laser radiation backscattered from natural targets. He/Ne Laser System for remote scanning of Methane leaks employs topographic target to scatter light to receiver near laser transmitter. Apparatus powered by 1.5kW generator transported to field sites and pointed at suspected methane leaks. Used for remote detection of natural-gas leaks and locating methane emissions in landfill sites.
NASA Astrophysics Data System (ADS)
Vitushkin, L. F.; Zakharenko, Yu G.; Smirnov, M. Z.
1990-05-01
Theoretical and experimental investigations were made of the principal physical factors responsible for a long-term drift of the frequency of the radiation generated in a stabilized two-frequency He-Ne laser with internal mirrors, emitting two orthogonally polarized electromagnetic waves. When zero difference between the intensities was controlled by a modulation method and the frequency was set before each measurement, a long-term (over a period of a year) frequency drift did not exceed 10 - 8, but in the absence of such control the drift could reach 5 × 10 - 8.
Backscattering measuring system for optimization of intravenous laser irradiation dose
NASA Astrophysics Data System (ADS)
Rusina, Tatyana V.; Popov, V. D.; Melnik, Ivan S.; Dets, Sergiy M.
1996-11-01
Intravenous laser blood irradiation as an effective method of biostimulation and physiotherapy becomes a more popular procedure. Optimal irradiation conditions for each patient are needed to be established individually. A fiber optics feedback system combined with conventional intravenous laser irradiation system was developed to control of irradiation process. The system consists of He-Ne laser, fiber optics probe and signal analyzer. Intravenous blood irradiation was performed in 7 healthy volunteers and 19 patients with different diseases. Measurements in vivo were related to in vitro blood irradiation which was performed in the same conditions with force-circulated venous blood. Comparison of temporal variations of backscattered light during all irradiation procedures has shown a strong discrepancy on optical properties of blood in patients with various health disorders since second procedure. The best cure effect was achieved when intensity of backscattered light was constant during at least five minutes. As a result, the optical irradiation does was considered to be equal 20 minutes' exposure of 3 mW He-Ne laser light at the end of fourth procedure.
Three-channel imaging fabry-perot interferometer for measurement of mid-latitude airglow.
Shiokawa, K; Kadota, T; Ejiri, M K; Otsuka, Y; Katoh, Y; Satoh, M; Ogawa, T
2001-08-20
We have developed a three-channel imaging Fabry-Perot interferometer with which to measure atmospheric wind and temperature in the mesosphere and thermosphere through nocturnal airglow emissions. The interferometer measures two-dimensional wind and temperature for wavelengths of 630.0 nm (OI, altitude, 200-300 km), 557.7 nm (OI, 96 km), and 839.9 nm (OH, 86 km) simultaneously with a time resolution of 20 min, using three cooled CCD detectors with liquid-N(2) Dewars. Because we found that the CCD sensor moves as a result of changes in the level of liquid N(2) in the Dewars, the cooling system has been replaced by thermoelectric coolers. The fringe drift that is due to changes in temperature of the etalon is monitored with a frequency-stabilized He-Ne laser. We also describe a data-reduction scheme for calculating wind and temperature from the observed fringes. The system is fully automated and has been in operation since June 1999 at the Shigaraki Observatory (34.8N, 136.1E), Shiga, Japan.
Rabbit electroretinograms evoked by 632.8nm laser flash stimuli
NASA Astrophysics Data System (ADS)
Yang, Zai-Fu; Chen, Hong-Xia; Wang, Jia-Rui; Guan, Bo-Lin; Yu, Guang-Yuan; Zhang, Xiao-Na; Zhang, Wen-Yuan; Yang, Jing-Geng
2012-12-01
The flash electroretinography is a standard electrophysiological method and widely employed in basic research and ophthalmology clinics, of which the stimulus is usually white flash from dome stimulator. However, little is known about the electroretinograms (ERGs) evoked by monochromatic laser flash stimuli. The goal of this research effort is to quantify the ERGs of dark-adapted New Zealand rabbits elicited by He-Ne laser flash with wavelength 632.8 nm. The flash field was a Maxwellian viewing disc with angular subtense of 8.5°, 13.3° or 20.2°. The stimulus duration was 12 ms, 22 ms, 70 ms or 220 ms. The laser flash power incident on the cornea varied from 2.2 nW through 22 mW. Under the condition of 20 ms stimulus duration and 20.2° flash field, the ERG of New Zealand rabbit was compared with that of Chinchilla gray rabbit. Results showed that for the ERG b-wave, with the increase of laser energy, the amplitude first increased, then met a trough and finally increased again, the implicit time decreased first and then met a platform. While for the ERG a-wave, the amplitude increased and the implicit time decreased monotonically. Longer stimulus duration led to lower b-wave amplitude under equal flash power level. The flash field size showed limited effect on the ERG, especially on the low energy end. As compared with the pigmented rabbit, the albino rabbit was more sensitive and the threshold energy for b-wave excitation was about 10 times lower.
Coherent double-color interference microscope for traceable optical surface metrology
NASA Astrophysics Data System (ADS)
Malinovski, I.; França, R. S.; Bessa, M. S.; Silva, C. R.; Couceiro, I. B.
2016-06-01
Interference microscopy is an important field of dimensional surface metrology because it provides direct traceability of the measurements to the SI base unit definition of the metre. With a typical measurement range from micrometres to nanometres interference microscopy (IM) covers the gap between classic metrology and nanometrology, providing continuous transfer of dimensional metrology into new areas of nanoscience and nanotechnology. Therefore IM is considered to be an indispensable tool for traceable transfer of the metre unit to different instruments. We report here the metrological study of an absolute Linnik interference microscope (IM) based on two frequency stabilized lasers. The design permits the flexible use of both lasers for measurements depending on the demand of the concrete measurement task. By principle of operation IM is combination of imaging and phase-shifting interferometry (PSI). The traceability is provided by the wavelength reference, that is, a He-Ne 633 nm stabilized laser. The second laser source, that is, a Blue-Green 488 nm grating stabilized laser diode, is used for improvements of resolution, and also for resolving integer fringe discontinuities on sharp features of the surface. The IM was optimized for surface height metrology. We have performed the study of the systematic effects of the measurements. This study allowed us to improve the hardware and software of IM and to find corrections for main systematic errors. The IM is purposed for 1D to 3D height metrology and surface topography in an extended range from nanometres to micrometres. The advantages and disadvantages of the design and developed methods are discussed.
Mjollnir Rotational Line Scan Diagnostics.
1981-05-19
using long cavity. M8 Removable Pellicle Beam Splitter for He-Ne Lineup Beam. Removed before HF or DF laser is turned on. 27 A 27 * A r of the chopper...three probe laser lines, however three lines were sequentially measured to verify the diagnostic equipment. Two of the three lines have been monitored
Aggregation of nanoparticles in endosomes and lysosomes produces surface-enhanced Raman spectroscopy
NASA Astrophysics Data System (ADS)
Lucas, Leanne J.; Chen, Xiaoke K.; Smith, Aaron J.; Korbelik, Mladen; Zeng, Haishan; Lee, Patrick W. K.; Hewitt, Kevin Cecil
2015-01-01
The purpose of this study was to explore the use of surface-enhanced Raman spectroscopy (SERS) to image the distribution of epidermal growth factor receptor (EGFR) in cells. To accomplish this task, 30-nm gold nanoparticles (AuNPs) tagged with antibodies to EGFR (1012 per mL) were incubated with cells (106 per mL) of the A431 human epidermoid carcinoma and normal human bronchial epithelial cell lines. Using the 632.8-nm excitation line of a He-Ne laser, Raman spectroscopy measurements were performed using a point mapping scheme. Normal cells show little to no enhancement. SERS signals were observed inside the cytoplasm of A431 cells with an overall enhancement of 4 to 7 orders of magnitude. Raman intensity maps of the 1450 and 1583 cm-1 peaks correlate well with the expected distribution of EGFR and AuNPs, aggregated following uptake by endosomes and lysosomes. Spectral features from tyrosine and tryptophan residues dominate the SERS signals.
NASA Astrophysics Data System (ADS)
Pramodini, S.; Sudhakar, Y. N.; SelvaKumar, M.; Poornesh, P.
2014-04-01
We present the synthesis and characterization of third-order optical nonlinearity and optical limiting of the conducting polymers poly (aniline-co-o-anisidine) and poly (aniline-co-pyrrole). Nonlinear optical studies were carried out by employing the z-scan technique using a He-Ne laser operating in continuous wave mode at 633 nm. The copolymers exhibited a reverse saturable absorption process and self-defocusing properties under the experimental conditions. The estimated values of βeff, n2 and χ(3) were found to be of the order of 10-2 cm W-1, 10-5 esu and 10-7 esu respectively. Self-diffraction rings were observed due to refractive index change when exposed to the laser beam. The copolymers possess a lower limiting threshold and clamping level, which is essential to a great extent for power limiting devices. Therefore, copolymers of aniline emerge as a potential candidate for nonlinear optical device applications.
The effect of low-intensity laser therapy on wound healing in Streptozotocin-induced diabetic rats
NASA Astrophysics Data System (ADS)
Rabelo, Sylvia B.; Villaverde, Antonio G. J. B.; Salgado, Miguel A. C.; Melo, Milene d. S.; Nicolau, Renata A.; Pacheco, Marcos T. T.
2004-10-01
Diabetes Mellitus is a condition that results in a delay of the wound healing process, that is associated with an insufficient production of collagen, a decrease of the amount of collagen fibrils and deficient blood flow in the wound area. It is sugested that Low Intensity Laser Therapy acts by improving wound healing in normal organisms, accelerating tissue regeneration. The aim of this work was to investigate the biostimulatory effect of the HeNe laser irradiation, at 632.8 nm, on wound healing in 15 male rats suffering from diabetes induced by Streptozotocin, compared to 15 control diabetic animals. Irradiation parameters were: laser power of 15mW, exposition time of 17 s., irradiated area of 0.025 cm2 and laser energy density of 10 J/cm2. Full-thickness skin squared samples, with 5 mm of non-injured tissue around the wound, were obtained at 4, 7 and 15 days after wounding procedure (5 treated and 5 control animals each time). The histopathologic analysis performed by haematoxylin-cosin staining. Results suggested that the irradiation of diabetic rats was efficient for wound healing. Treated group presented better quality of the wound tissues by the macroscopic observation than control group and the microscopic analysis demonstrated that treated animals had better histopathologic evaluation than non treated.
NASA Astrophysics Data System (ADS)
Ho, Gideon; Barbenel, Joseph; Grant, M. Helen
2009-05-01
Fibroblast-populated collagen lattices (FPCL) are widely used in tissue-engineered artificial skin substitutes, but their main drawback is that interaction of fibroblasts and matrix causes contraction of the lattice, reducing it to about 20% of its original area. The effect of low-level laser treatment (LLLT) on the behavior of 3T3 fibroblasts seeded in collagen lattices containing 20% chondroitin-6-sulphate was investigated to determine whether LLLT could control the contraction of FPCL. A He-Ne laser was used at 632.8 nm to deliver a 5-mW continuous wave with fluences from 1 to 4 J/cm2. Laser treatment at 3 J/cm2 increased contraction of collagen lattices in the absence of cells but decreased contraction of cell seeded lattices over a 7-day period. The effect was energy dependent and was not observed at 1, 2, or 4 J/cm2. There was no alteration in fibroblast viability, morphology, or mitochondrial membrane potential after any laser treatments, but the distribution of actin fibers within the cells and collagen fibers in the matrices was disturbed at 3 J/cm2. These effects contribute to the decrease in contraction observed. LLLT may offer a means to control contraction of FPCL used as artificial skin substitutes.
Shell-Type Micromechanical Oscillator
2003-04-01
interferometric setup. A positive feedback loop was implemented by amplifying the red laser signal (related to the oscillator deflection) and using...resonator was actuated by a sharply focused, modulated Ar+ ion (blue) laser beam and detected by a red HeNe laser using an interferometric setup. A positive...top. Fig. 1 shows optical micrograph obtained by DIC (Differential Interference Contrast, known also as Nomarsky contrast). An array of three domes
Laser plasmapheresis for treatment of pulmonary and pleural suppurative diseases
NASA Astrophysics Data System (ADS)
Akopov, A. L.; Bely, K. P.; Berezin, Yu. D.; Orlov, S. V.
1996-04-01
Plasmapheresis in pulmonology is one of the leading methods of extracorporeal detoxification of patients with purulent lung and pleura diseases. However this method causes a decrease in patients' leukocyte level and humoral immunity indices. The medico-biological research conducted at the State Scientific Center of Pulmonology demonstrated that a combination of plasmapheresis with additional irradiation of the patients' reinfused erythrocyte mass with low intensive He-Ne laser light with the wavelength of 0.63 mkm considerably reduces the probability of these complications. It may be due to the fact that laser irradiation of autologous erythrocytes induces local and general stimulation, favoring in this way the inflammatory process involution. The suggested method of plasmapheresis was used in the process of treatment of 76 patients with lung abscess, empyema, purulent mediastinitis, sepsis. The essence of the method consists in irradiating with He-Ne laser the last portion of the erythrocyte mass (130 - 170 ml), diluted with saline, during its reinfusion in the course of a routine plasmapheresis. The positive impact of practical application of the above method allows to characterize it as highly effective for treatment of purulent diseases in pulmonology.
NASA Astrophysics Data System (ADS)
Nahal, Arashmid; Kashani, Somayeh
2017-09-01
Irradiation of AgCl-Ag thin films by a linearly polarized He-Ne laser beam results in the formation of self-organized periodic nanostructures. As a result of secondary irradiation of the initially exposed sample by the same linearly polarized He-Ne laser beam, but with different orientations of polarization, a complex crossed-chain nanostructure forms. We found that such a complex nanostructure has noticeable chirality and increased optical anisotropy, resulting in optical activity of the sample. Double exposure produces two gratings, crossing each other with angle α, which leads to the formation of crossed building blocks with chiroptical effects. It is established that the amount and the sign of the angle between the two laser-induced gratings (±α) determine the amount and the direction of rotation of the linearly polarized probe beam, respectively. We have also observed an induced anisotropy-dependent ellipticity for the probe light, which is passed through the sample. It is shown that the amount of ellipticity depends on the angle α.
Nonlinear optical properties of Nd3+-Li+ co-doped ZnS-PVP thin films
NASA Astrophysics Data System (ADS)
Talwatkar, S. S.; Sunatkari, A. L.; Tamgadge, Y. S.; Muley, G. G.
2018-04-01
The nonlinear optical properties of Nd3+-Li+ co-doped ZnS-PVP nanocomposite were studied using a continuous wave (CW) He-Ne laser (λ = 632.8 nm)by z-scan technique. The nonlinear refractive index (n2), absorption coefficient (β) and third order nonlinear susceptibility (χ(3)) of PVP thin films embedded with Nd3+-Li+ co-doped ZnS NPs was found in the order of 10-7 cm2/W, 10-6 cm/W and 10-7 esu respectively. The nonlinearity found increasing with Nd3+-Li+ co-dopant concentration. Based on the results, it is proposed that this material is a new class of luminescent material suitable in optoelectronics devices application, especially in light-emitting devices, electroluminescent devices, display devices, etc.
Corneal collagen denaturation in laser thermokeratoplasty
NASA Astrophysics Data System (ADS)
Brinkmann, Ralf; Kampmeier, Juergen; Grotehusmann, Ulf; Vogel, Alfred; Koop, Norbert; Asiyo-Vogel, Mary; Birngruber, Reginald
1996-05-01
In laserthermokeratoplasty (LTK) thermal denaturation and shrinkage of corneal collagen is used to correct hyperopia and astigmatism. In order to optimize dosimetry, the temperature at which maximal shrinkage of collagen fibrils occurs is of major interest. Since the exposure time in clinical LTK-treatment is limited to a few seconds, the kinetics of collagen denaturation as a rate process has to be considered, thus the time of exposure is of critical importance for threshold and shrinkage temperatures. We investigated the time-temperature correlation for corneal collagen denaturation within different time domains by turbidimetry of scattered HeNe laser probe light using a temperature controlled water bath and pulsed IR laser irradiation. In the temperature range of 60 degree(s)C to 95 degree(s)C we found an exponential relation between the denaturation time and temperature. For the typical LTK-treatment time of 2 s, a temperature of 95 degree(s)C is needed to induce thermal damage. Use of pulsed Holmium laser radiation gave significant scattering of HeNe laser probe light at calculated temperatures of around 100 degree(s)DC. Rate parameters according to the formalism of Arrhenius were fitted to these results. Force measurements showed the simultaneous onset of light scattering and collagen shrinkage.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hu, Michael Z.; Easterly, Clay E
Solution synthesis of nanocrystal silver is reviewed. This paper reports a novel thermal electrochemical synthesis (TECS) for producing metal Ag nanocrystals as small as a few nanometers. The TECS method requires mild conditions (25-100oC), low voltage (1-50 V DC) on Ag electrodes, and simple water or aqueous solutions as reaction medium. Furthermore, a tubular dialysis membrane surround electrodes proves favorable to produce nanosized (<10 nm) Ag nanocrystals. Different from those nanocrystals reported in literature, our nanocrystals have several unique features: (1) small nanometer size, (2) nakedness , i.e., surfaces of metal nanocrystals are free of organic ligands or capping moleculesmore » and no need of dispersant in synthesis solutions, and (3) colloidally stable in water solutions. It was discovered that Ag nanoparticles with initially large size distribution can be homogenized into near-monodispersed system by a low power (< 15 mW) He-Ne laser exposure treatment. The combination of the TECS technique and the laser treatment could lead to a new technology that produces metal nanoparticles that are naked, stable, and uniform sized. In the presence of stabilizing agent (also as supporting electrolyte) such as polyvinyl alcohol (PVA), large yield of silver nanoparticles (<100nm) in the form of thick milky sols are produced.« less
Airborne water vapor DIAL system and measurements of water and aerosol profiles
NASA Technical Reports Server (NTRS)
Higdon, Noah S.; Browell, Edward V.
1991-01-01
The Lidar Applications Group at NASA Langley Research Center has developed a differential absorption lidar (DIAL) system for the remote measurement of atmospheric water vapor (H2O) and aerosols from an aircraft. The airborne H2O DIAL system is designed for extended flights to perform mesoscale investigations of H2O and aerosol distributions. This DIAL system utilizes a Nd:YAG-laser-pumped dye laser as the off-line transmitter and a narrowband, tunable Alexandrite laser as the on-line transmitter. The dye laser has an oscillator/amplifier configuration which incorporates a grating and prism in the oscillator cavity to narrow the output linewidth to approximately 15 pm. This linewidth can be maintained over the wavelength range of 725 to 730 nm, and it is sufficiently narrow to satisfy the off-line spectral requirements. In the Alexandrite laser, three intracavity tuning elements combine to produce an output linewidth of 1.1 pm. These spectral devices include a five-plate birefringent tuner, a 1-mm thick solid etalon and a 1-cm air-spaced etalon. A wavelength stability of +/- 0.35 pm is achieved by active feedback control of the two Fabry-Perot etalons using a frequency stabilized He-Ne laser as a wavelength reference. The three tuning elements can be synchronously scanned over a 150 pm range with microprocessor-based scanning electronics. Other aspects of the DIAL system are discussed.
[Combined use of various laser radiations in thoracic surgery in experimental studies].
Ismailov, D A; Khoroshaev, V A; Shishkin, M A; Baĭbekov, I M
1993-01-01
The impact of various types of low-intensive lasers (He-Ne, copper vapour, ultraviolet, infrared, infrared gallium arsenide) on healing of a wound made by CO2 laser at an output power of 25 W was studied in an experiment on 120 albino Wistar rats. It was found that a concurrent application of high- and low-intensive lasers resulted in acceleration of reparative processes in the lung, stimulating the healing of laser-induced wounds. The infrared gallium arsenide laser was demonstrated to be the best tool in stimulating the healing process.
Influence of low-power laser radiation on mast cells function and biogenic amines content in stress
NASA Astrophysics Data System (ADS)
Brill, Gregory E.; Dobrovolsky, Gennady A.; Romanova, Tatyana P.; Brill, Alexander G.
1997-06-01
In experiments on white male rats stress was modeled by combined action of immobilization and sound stimulus during 2 h. It was established that stress induced storage of secretory material and accumulation of biogenic amines in mast cells. Preliminary transcutaneous He-Ne laser irradiation prevented stress-induced changes.
Towards real time speckle controlled retinal photocoagulation
NASA Astrophysics Data System (ADS)
Bliedtner, Katharina; Seifert, Eric; Stockmann, Leoni; Effe, Lisa; Brinkmann, Ralf
2016-03-01
Photocoagulation is a laser treatment widely used for the therapy of several retinal diseases. Intra- and inter-individual variations of the ocular transmission, light scattering and the retinal absorption makes it impossible to achieve a uniform effective exposure and hence a uniform damage throughout the therapy. A real-time monitoring and control of the induced damage is highly requested. Here, an approach to realize a real time optical feedback using dynamic speckle analysis is presented. A 532 nm continuous wave Nd:YAG laser is used for coagulation. During coagulation, speckle dynamics are monitored by a coherent object illumination using a 633nm HeNe laser and analyzed by a CMOS camera with a frame rate up to 1 kHz. It is obvious that a control system needs to determine whether the desired damage is achieved to shut down the system in a fraction of the exposure time. Here we use a fast and simple adaption of the generalized difference algorithm to analyze the speckle movements. This algorithm runs on a FPGA and is able to calculate a feedback value which is correlated to the thermal and coagulation induced tissue motion and thus the achieved damage. For different spot sizes (50-200 μm) and different exposure times (50-500 ms) the algorithm shows the ability to discriminate between different categories of retinal pigment epithelial damage ex-vivo in enucleated porcine eyes. Furthermore in-vivo experiments in rabbits show the ability of the system to determine tissue changes in living tissue during coagulation.
NASA Astrophysics Data System (ADS)
El Batanouny, Mohamed H.; Khorshid, Amira M.; Arsanyos, Sonya F.; Shaheen, Hesham M.; Abdel Wahab, Nahed; Amin, Sherif N.; El Rouby, Mahmoud N.; Morsy, Mona I.
2010-04-01
Photodynamic therapy (PDT) is a novel treatment modality of cancer and non-cancerous conditions that are generally characterized by an overgrowth of unwanted or abnormal cells. Irradiation of photosensitizer loaded cells or tissues leads via the photochemical reactions of excited photosensitizer molecules to the production of singlet oxygen and free radicals, which initiate cell death. Many types of compounds have been tested as photosensitizers, such as methylene blue (MB) and photopherin seemed to be very promising. This study involved 26 cases of acute lymphoblastic leukemia and 15 normal volunteers as a control group. The cell viability was measured by Light microscope and flowcytometer. Mode of cell death was detected by flowcytometer and electron microscope in selected cases. The viability percentage of normal peripheral blood mononuclear cells (PBMC) incubated with methylene blue (MB) alone or combined with photo irradiation with diode laser (as measured by light microscope) was significantly lower than that of untreated cases either measured after 1 hour (p<0.001) or 24 hours (p<0.001) post incubation. There was a significantly lower viability percentage of normal cells incubated with MB and photoirradiated with diode laser compared to normal cells treated with MB alone for either measured after 1 hour (p<0.001) or 24 hours (p<0.001) post incubation. The decrease in viability was more enhanced with increasing the incubation time. For normal cells incubated with photopherin either for 1/2 an hour or 1 hour, there was a weak cytotoxic effect compared to the effect on untreated cells. There was a significant decrease in viability percentage of cells incubated with photopherin either for 1/2 an hour or 1 hour and photoirradiated with He:Ne laser compared to normal untreated cells. The decrease in the cell viability percentage was significantly lower with the use of PDT (photopherin and He:Ne laser ) compared to either photopherin alone or He:Ne laser alone. The decrease in viability was more enhanced with increasing the incubation time. The same effects reported on normal cells were detected on leukemic cells on comparing different methods used. However a more pronounced decrease in cell viability was detected. The most efficient ways of decreasing viability of leukemic cells with much less effect on normal cells was the use of PDT of cell incubation with MB for 1 hour then photoirradiation with diode laser and PDT of cell incubation with photopherin for 1 hour then photoirradiation with He:Ne laser. Flowcytometer (FCM) was more sensitivite than the light microscope in detecting the decrease in cell viability, it also helped in determining the mode of cell death weather apoptosis, necrosis or combined apoptosis and necrosis. Apoptotic cell percentage was higher in PDT of MB and Diode laser or photopherin and He:Ne laser, treated ALL cells compared to untreated ALL cells after 1 hour but was significantly lower after 24 hours post irradiation. A significant increase in necrotic, combined necrotic and apoptotic cell percentages either measured 1 hour or 24 hours post PDT, compared to untreated ALL cells and PDT treated normal cells. Electron microscope helped in detecting early cellular apoptotic changes occurring in response to different therapeutic modalities used in this study. In conclusion, PDT proved to be an effective clinical modality in decreasing the number of leukemic cells when irradiated in vitro with appropriate laser and photosensitizer system. Both PDT systems used in this study were efficient in inducing cell death of leukemic cells compared to untreated leukemic cells. However, photopherin PDT system was more efficient in decreasing the cell viability. A significant decrease in viability percentage was detected when studying the effect of PDT on leukemic cells compared to that on normal cells. This suggests that PDT when applied clinically will selectively differentiate between leukemic cells and normal cells, offering a successful component in ALL therapy.
Guiselini, Monalisa Jacob; Deana, Alessandro Melo; de Fátima Teixeira da Silva, Daniela; Koshoji, Nelson Hideyoshi; Mesquita-Ferrari, Raquel Agnelli; do Vale, Katia Llanos; Mascaro, Marcelo Betti; de Moraes, Simone Aleksandra; Bussadori, Sandra Kalil; Fernandes, Kristianne Porta Santos
2017-06-01
Bone tissue anatomy, density and porosity vary among subjects in different phases of life and even within areas of a single specimen. The optical characteristics of changes in bone tissue are analyzed based on these properties. Photobiomodulation has been used to improve bone healing after surgery or fractures. Thus, knowledge on light propagation is of considerable importance to the obtainment of successful clinical outcomes. This study determines light penetration and distribution in human maxillary and mandibular bones in three different regions (anterior, middle, and posterior). A HeNe laser (633nm) irradiated maxillary and mandibular bones in the cervical-apical direction. The light propagation and scattering pattern were acquired and the grey level of the images was analyzed. Three-dimensional plots of the intensity profile and attenuation profiles were created. Differences in optical properties were found between the mandibular and maxillary bones. The maxilla attenuated more light than the mandible at all sites, leading to a shallower penetration depth. Our results provide initial information on the behavior of the propagation of red laser on alveolar bone using an optical method. Copyright © 2017 Elsevier B.V. All rights reserved.
Frequency measurement of the 260-THz (1. 15-. mu. m) He--Ne laser
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jennings, D.A.; Petersen, F.R.; Evenson, K.M.
1979-05-01
Absolute infrared frequency measurement has been extended to 260 THz with the measurement of the strong 1.15-..mu..m laser line in /sup 20/Ne. The frequency was synthesized in nonlinear crystals of CdGeAs/sub 2/ and Ag/sub 3/AsS/sub 3/ from stabilized CO/sub 2/ lasers and the 1.5-..mu..m laser line in /sup 20//sub Ne.Themeasuredfrequencyis/..nu..20/sub Ne,1.15mum/ =260.103 284 (30) THz.
Optical Properties of Compressible Inhomogeneous Shear Layers Relevant to High Power Lasers.
1987-09-30
trend of laser development towards shorter wavelenghts , the fluid optics challenge is increased con- siderahly. In general, the conditioning of the gas...tion pattern of laser beams passing through the layer. We hoped to under- ", stand and to predict compressible shear layer growth rate and optical per...layer growth rates for jet Mach numbers of 0.1, 0.3 and n.6 were measured using a Mach-Zehnder interferometer. Interferograms using a He-Ne laser source
Controlling the non-linear intracavity dynamics of large He-Ne laser gyroscopes
NASA Astrophysics Data System (ADS)
Cuccato, D.; Beghi, A.; Belfi, J.; Beverini, N.; Ortolan, A.; Di Virgilio, A.
2014-02-01
A model based on Lamb's theory of gas lasers is applied to a He-Ne ring laser (RL) gyroscope to estimate and remove the laser dynamics contribution from the rotation measurements. The intensities of the counter-propagating laser beams exiting one cavity mirror are continuously observed together with a monitor of the laser population inversion. These observables, once properly calibrated with a dedicated procedure, allow us to estimate cold cavity and active medium parameters driving the main part of the non-linearities of the system. The quantitative estimation of intrinsic non-reciprocal effects due to cavity and active medium non-linear coupling plays a key role in testing fundamental symmetries of space-time with RLs. The parameter identification and noise subtraction procedure has been verified by means of a Monte Carlo study of the system, and experimentally tested on the G-PISA RL oriented with the normal to the ring plane almost parallel to the Earth's rotation axis. In this configuration the Earth's rotation rate provides the maximum Sagnac effect while the contribution of the orientation error is reduced to a minimum. After the subtraction of laser dynamics by a Kalman filter, the relative systematic errors of G-PISA reduce from 50 to 5 parts in 103 and can be attributed to the residual uncertainties on geometrical scale factor and orientation of the ring.
NASA Astrophysics Data System (ADS)
Faraji, Nastaran; Mahmood Mat Yunus, W.; Kharazmi, Alireza; Saion, Elias; Behzad, Kasra
2014-01-01
CdS nanofluids were prepared by the gamma-radiation method at different radiation doses. The samples were characterized by UV-Vis spectroscopy and transmission electron microscopy. The open cell photoacoustic technique was used to measure the thermal effusivity of the CdS nanocomposites. In this technique a He-Ne laser was used as the excitation source and was operated at 632.8 nm with an output power of 70 mW. The precision and accuracy of this technique were initially established by measuring the thermal effusivity of distilled water and ethylene glycol. The thermal-effusivity values of these two samples were found to be close to the values reported in the literature. The thermal effusivity of CdS nanofluids decreased from (0.453 to 0.268) with increased dosage of gamma radiation.
Soot formation in shock-tube pyrolysis and oxidation of vinylacetylene
NASA Technical Reports Server (NTRS)
Frenklach, M.; Yuan, T.; Ramachandra, M. K.
1990-01-01
Soot formation in vinylacetylene, and vinylacetylene-oxygen argon-diluted mixtures was studied behind reflected shock waves by monitoring the attenuation of a 632.8-nm He-Ne laser beam. The experiments were performed at temperatures of 1600-2500 K, pressures of 2.08-3.09 bar, and total carbon atom concentrations of (1.99-2.05) x 10 to the 17th atoms/cu cm. The experimental results obtained in pyrolysis of vinylacetylene are similar to those of acetylene, both in the order of magnitude of the soot yield and the shape of its temperature dependence. The addition of oxygen to vinylacetylene shifts the soot bell to lower temperature and, distinct from all other hydrocarbons studied in this laboratory, accelerates the production of soot with reaction time. The experimental results are interpreted in terms of possible chemical reaction.
NASA Astrophysics Data System (ADS)
Khairullina, Alphiya Y.; Oleinik, Tatiana V.
1995-01-01
Our previous works concerned with the development of methods for studying blood and action of low-intensity laser radiation on blood and erythrocyte suspensions had shown the light- scattering methods gave a large body of information on a medium studied due to the methodological relationship between irradiation processes and techniques for investigations. Detail analysis of spectral diffuse reflectivities and transmissivities of optically thick blood layers, spectral absorptivities calculated on this basis over 600 - 900 nm, by using different approximations, for a pathological state owing to hypoxia testifies to the optical significance of not only hemoglobin derivatives but also products of hemoglobin decomposition. Laser action on blood is specific and related to an initial state of blood absorption due to different composition of chromoproteids. This work gives the interpretation of spectral observations. Analysis of spectral dependencies of the exinction coefficient e, mean cosine m of phase function, and parameter Q equals (epsilon) (1-(mu) )H/(lambda) (H - hematocrit) testifies to decreasing the relative index of refraction of erythrocytes and to morphological changes during laser action under pathology owing to hypoxia. The possibility to obtain physical and chemical information on the state of blood under laser action in vivo is shown to be based on the method proposed by us for calculating multilayered structures modeling human organs and on the technical implementation of this method.
Low-level laser therapy on MCF-7 cells: a micro-Fourier transform infrared spectroscopy study
NASA Astrophysics Data System (ADS)
Magrini, Taciana D.; dos Santos, Nathalia Villa; Milazzotto, Marcella Pecora; Cerchiaro, Giselle; da Silva Martinho, Herculano
2012-10-01
Low-level laser therapy (LLLT) is an emerging therapeutic approach for several clinical conditions. The clinical effects induced by LLLT presumably scale from photobiostimulation/photobioinhibition at the cellular level to the molecular level. The detailed mechanism underlying this effect remains unknown. This study quantifies some relevant aspects of LLLT related to molecular and cellular variations. Malignant breast cells (MCF-7) were exposed to spatially filtered light from a He-Ne laser (633 nm) with fluences of 5, 28.8, and 1000 mJ/cm2. The cell viability was evaluated by optical microscopy using the Trypan Blue viability test. The micro-Fourier transform infrared technique was employed to obtain the vibrational spectra of each experimental group (control and irradiated) and identify the relevant biochemical alterations that occurred due to the process. It was observed that the red light influenced the RNA, phosphate, and serine/threonine/tyrosine bands. We found that light can influence cell metabolism depending on the laser fluence. For 5 mJ/cm2, MCF-7 cells suffer bioinhibition with decreased metabolic rates. In contrast, for the 1 J/cm2 laser fluence, cells present biostimulation accompanied by a metabolic rate elevation. Surprisingly, at the intermediate fluence, 28.8 mJ/cm2, the metabolic rate is increased despite the absence of proliferative results. The data were interpreted within the retrograde signaling pathway mechanism activated with light irradiation.
Research on radiation induced laser plasmas
NASA Technical Reports Server (NTRS)
Schneider, R. T.; Rowe, M. J.; Carter, B. D.; Walters, R. A.; Cox, J. D.; Liang, R.; Roxey, T.; Zapata, L.
1979-01-01
The development of high power nuclear pumped lasers is discussed. The excitation mechanism of continuous wave (CW) HeNe nuclear pumped lasers is studied and a CO2 nuclear pumped laser is used to demonstrate the CW output in the order of watts. The assumption that high power densities are only achievable by volume fission fragment sources is used to identify laser gases which are compatible with UF6 by excited states lifetime measurements. The examination of Xe2, XeF, and KrF under nuclear irradiation to determine if they are good candidates for nuclear-pumped lasers is described.
NASA Astrophysics Data System (ADS)
Onac, I.; Pop, L.; Ungur, Rodica; Giurgiu, Ioana
2001-06-01
We checked the changes occurring in the metabolism of proteins (seric cholinesterase, total proteins) and in the metabolism of glycosides (seric glucose) in Cavia cobaia. A simple blind study was carried out and the results were checked on the first, tenth and twentieth days of treatment. The data thus obtained were graphically represented and statistically processed according to the Duncan test. The technique and treatment doses were similar and they were compared with the data obtained from controls and environment controls. In the groups biostimulated with He-Ne laser, seric cholinesterase levels increased proportionally with the dose reaching a peak on day 10, which was not the case with the controls. Monochromatic red light caused a similar but quantitatively lower effect. The same results were obtained in the case of seric proteins as well, however, the effect did not depend on the dose and it was less significant statistically than in the case of seric cholinesterase both in laser treated and in monochromatic red light treated groups.
NASA Astrophysics Data System (ADS)
Seo, Jeong Hyun; Jeong, Heui Seob; Lee, Joo Yul; Yoon, Cha Keun; Kim, Joong Kyun; Whang, Ki-Woong
2000-08-01
We measured the time integrated vacuum ultraviolet (VUV) emission spectra of He-Ne-Xe gas mixture from a surface type alternating current (ac) plasma display panel cell. The measured emission lines are the resonance line (147 nm) from Xe*(1s4), the first continuum (150 nm) and the second continuum (173 nm) from Xe dimer excited states. The relative intensities of VUV spectral lines from Xe* and Xe2* are dependent on the He/Ne mixing ratio as well as the Xe partial and total pressure. The intensity of 147 nm VUV increases with the Ne content increase and Xe2* molecular emission increases with the He content increase. Infrared (IR) spectra and the time variation of VUV were measured to explain the reaction pathway and the effect of the mixing ratio of He/Ne on the spectral intensity. A detailed study for the decay time shows that the decay time of 147 nm has two time constants and the radiation of 150 and 173 nm results mainly from Xe*(1s5). The IR spectra shows that the contribution from Xe**(>6 s) to Xe*(1s5) and Xe*(1s4) in He-Xe is different from that of Ne-Xe. The change of IR intensity explains the spectral intensity variations of He-Xe and Ne-Xe discharge.
NASA Technical Reports Server (NTRS)
Ducas, T. W.; Feld, M. S.; Ryan, L. W., Jr.; Skribanowitz, N.; Javan, A.
1972-01-01
Observation results are presented on the optical hyperfine structure in Ne-21 obtained with the aid of laser-induced line-narrowing techniques. The output from a long stabilized single-mode 1.15-micron He-Ne laser focused into an external sample cell containing Ne-21 was used in implementing these techniques. Their applicability is demonstrated for optical hyperfine structure observation in systems whose features are ordinarily masked by Doppler broadening.
Characterization of laser damage performance of fused silica using photothermal absorption technique
NASA Astrophysics Data System (ADS)
Wan, Wen; Shi, Feng; Dai, Yifan; Peng, Xiaoqiang
2017-06-01
The subsurface damage and metal impurities have been the main laser damage precursors of fused silica while subjected to high power laser irradiation. Light field enhancement and thermal absorption were used to explain the appearance of damage pits while the laser energy is far smaller than the energy that can reach the intrinsic threshold of fused silica. For fused silica optics manufactured by magnetorheological finishing or advanced mitigation process, no scratch-related damage site occurs can be found on the surface. In this work, we implemented a photothermal absorption technique based on thermal lens method to characterize the subsurface defects of fused silica optics. The pump beam is CW 532 nm wavelength laser. The probe beam is a He-Ne laser. They are collinear and focused through the same objective. When pump beam pass through the sample, optical absorption induces the local temperature rise. The lowest absorptance that we can detect is about the order of magnitude of 0.01 ppm. When pump beam pass through the sample, optical absorption induces the local temperature rise. The photothermal absorption value of fused silica samples range from 0.5 to 10 ppm. The damage densities of the samples were plotted. The damage threshold of samples at 8J/cm2 were gived to show laser damage performance of fused silica.The results show that there is a strong correlation between the thermal absorption and laser damage density. The photothermal absorption technique can be used to predict and evaluate the laser damage performance of fused silica optics.
Polarization holographic optical recording of a new photochromic diarylethene
NASA Astrophysics Data System (ADS)
Pu, Shouzhi; Miao, Wenjuan; Chen, Anyin; Cui, Shiqiang
2008-12-01
A new symmetrical photochromic diarylethene, 1,2-bis[2-methyl-5-(3-methoxylphenyl)-3-thienyl]perfluorocyclopentene (1a), was synthesized, and its photochromic properties were investigated. The compound exhibited good photochromism both in solution and in PMMA film with alternating irradiation by UV/VIS light, and the maxima absorption of its closed-ring isomer 1b are 582 and 599 nm, respectively. Using diarylethene 1b/PMMA film as recording medium and a He-Ne laser (633 nm) for recording and readout, four types of polarization and angular multiplexing holographic optical recording were performed perfectly. For different types of polarization recording including parallel linear polarization recording, parallel circular polarization recording, orthogonal linear polarization recording and orthogonal circular polarization recording,have been accomplished successfully. The results demonstrated that the orthogonal circular polarization recording is the best method for polarization holographic optical recording when this compound was used as recording material. With angular multiplexing recording technology, two high contrast holograms were recorded in the same place on the film with the dimension of 0.78 μm2.
Study on optical properties of L-valine doped ADP crystal
NASA Astrophysics Data System (ADS)
Shaikh, R. N.; Anis, Mohd.; Shirsat, M. D.; Hussaini, S. S.
2015-02-01
Single crystal of L-valine doped ammonium dihydrogen phosphate has been grown by slow evaporation method at room temperature. The crystalline nature of the grown crystal was confirmed using powder X-ray diffraction technique. The different functional groups of the grown crystal were identified using Fourier transform infrared analysis. The UV-visible studies were employed to examine the high optical transparency and influential optical constants for tailoring materials suitability for optoelectronics applications. The cutoff wavelength of the title crystal was found to be 280 nm with wide optical band gap of 4.7 eV. The dielectric measurements were carried to determine the dielectric constant and dielectric loss at room temperature. The grown crystal has been characterized by thermogravimetric analysis. The second harmonic generation efficiency of the grown crystal was determined by the classical Kurtz powder technique and it is found to be 1.92 times that of potassium dihydrogen phosphate. The grown crystal was identified as third order nonlinear optical material employing Z-scan technique using He-Ne laser operating at 632.8 nm.
NASA Astrophysics Data System (ADS)
Zakariasen, Kenneth L.; Barron, Joseph R.; Paton, Barry E.
1992-06-01
Research has shown that low levels of CO2 laser irradiation raise enamel resistance to sub-surface demineralization. Additionally, laser scanned fluorescence analysis of enamel, as well a laser and white light reflection studies, have potential for both clinical diagnosis and comparative research investigations of the caries process. This study was designed to compare laser fluorescence and laser/white light reflection of (1) non-lased/normal with lased/normal enamel and (2) non-lased/normal with non-lased/carious and lased/carious enamel. Specimens were buccal surfaces of extracted third molars, coated with acid resistant varnish except for either two or three 2.25 mm2 windows (two window specimens: non-lased/normal, lased/normal--three window specimens: non-lased/normal, non-lased carious, lased/carious). Teeth exhibiting carious windows were immersed in a demineralizing solution for twelve days. Non-carious windows were covered with wax during immersion. Following immersion, the wax was removed, and fluorescence and laser/white light reflection analyses were performed on all windows utilizing a custom scanning laser fluorescence spectrometer which focuses light from a 25 mWatt He-Cd laser at 442 nm through an objective lens onto a cross-section >= 3 (mu) in diameter. For laser/white light reflection analyses, reflected light intensities were measured. A HeNe laser was used for laser light reflection studies. Following analyses, the teeth are sectioned bucco-lingually into 80 micrometers sections, examined under polarized light microscopy, and the lesions photographed. This permits comparison between fluorescence/reflected light values and the visualized decalcification areas for each section, and thus comparisons between various enamel treatments and normal enamel. The enamel specimens are currently being analyzed.
Heterogeneous MEMS Device Assembly and Integration
2014-04-01
included a camera, a He-Ne laser, attenuation filters, folding mirrors, the micromirror under test (MUT) and the observation plane. The MUT was...non activated mirror (the initial incidence plane) was horizontal. Figure 4: Micromirror characterization setup. The static response of a beam
Asghar, Tehseen; Iqbal, Munawar; Jamil, Yasir; Zia-Ul-Haq; Nisar, Jan; Shahid, Muhammad
2017-01-01
Recently, laser and magnetic field pre-sowing seed treatments attracted the attention of the scientific community in response to their positive effect on plant characteristics and the present study was exemplified for Glycine max Var 90-I. Seeds were exposed to laser (HeNe-wave length 632nm and density power of 1mW/cm 2 ) and magnetic field (sinusoidal non-uniform-50, 75 and 100mT for 3, 5min with exposure) and seed germination, seedling growth and yield attributes were compared. The germination (mean germination, germination percentage, emergence index, germination speed, relative germination coefficient, emergence coefficient of uniformity) growth (root dry weight, root length, shoot fresh weight and shoot dry weight, leaf dry & fresh weight, root fresh weight, leaf area, shoot length, plant total dry weight at different stages, stem diameter, number of leaves, vigor index I & II), biochemical (essential oil) and yield attributes (seed weight, count) were enhanced significantly in response to both laser and magnetic field treatments. However, magnetic field treatment furnished slightly higher response versus laser except relative water contents, whole plant weight and shoot length. Results revealed that both laser and magnetic field pre-sowing seed treatments affect the germination, seedling growth, and yield characteristics positively and could possibly be used to enhance Glycine max productivity. Copyright © 2016 Elsevier B.V. All rights reserved.
Laser Biostimulation Of Wound Healing In Arteriopatic Patients
NASA Astrophysics Data System (ADS)
Tallarida, G.; Baldoni, F.; Raimondi, G.; Massaro, M.; Peruzzi, G.; Bertolotti, M.; Ferrari, A.; Scudieri, F.
1981-05-01
Low-power laser irradiation has been employed in the attempt to accelerate the wound-healing of ischemic cutaneous ulcerations with threatening or manifest gangrene due to arteriosclerosis obliterans of the lower limbs. Irradiation was performed by using a low-power He-Ne gas laser of 6328 Å wavelength and was concentrated at the peripheral zone of the lesions. The preliminary results of the study indicate that laser stimulation might be new approach in the conservative menagement of the ischemic ulcers in patients with severe peripheral obstructive arteriopaties not suited for arterial reconstruction.
NASA Astrophysics Data System (ADS)
Iwamoto, D.; Sakuma, I.; Kitagawa, Y.; Kikuchi, Y.; Fukumoto, N.; Nagata, M.
2012-10-01
In next step of fusion devices such as ITER, lifetime of plasma-facing materials (PFMs) is strongly affected by transient heat and particle loads during type I edge localized modes (ELMs) and disruption. To clarify damage characteristics of the PFMs, transient heat and particle loads have been simulated by using a plasma gun device. We have performed simulation experiments by using a magnetized coaxial plasma gun (MCPG) device at University of Hyogo. The line-averaged electron density measured by a He-Ne interferometer is 2x10^21 m-3 in a drift tube. The plasma velocity measured by a time of flight technique and ion Doppler spectrometer was 70 km/s, corresponding to the ion energy of 100 eV for helium. Thus, the ion flux density is 1.4x10^26 m-2s-1. On the other hand, the MCPG is connected to a target chamber for material irradiation experiments. It is important to measure plasma parameters in front of target materials in the target chamber. In particular, a vapor cloud layer in front of the target material produced by the pulsed plasma irradiation has to be characterized in order to understand surface damage of PFMs under ELM-like plasma bombardment. In the conference, preliminary results of application of the He-Ne laser interferometer for the above experiment will be shown.
Ding, Li; Knox, Wayne H.; Bühren, Jens; Nagy, Lana J.; Huxlin, Krystel R.
2009-01-01
Purpose To assess the optical effect of high-repetition-rate, low energy femtosecond laser pulses on lightly-fixed corneas and lenses. Methods Eight corneas and eight lenses were extracted post-mortem from normal, adult cats. They were lightly fixed and stored in a solution that minimized swelling and opacification. An 800nm Ti:Sapphire femtosecond laser oscillator with a 27fs pulse duration and 93MHz repetition rate was used to inscribe gratings consisting of 20-40 lines, each 1μm wide, 100μm long and 5μm apart, 100μm below the tissue surface. Refractive index changes in the micromachined regions were calculated immediately and after one month of storage by measuring the intensity distribution of diffracted light when the gratings were irradiated with a 632.8nm He-Ne laser. Results Periodic gratings were created into the stromal layer of the corneas and the cortex of the lenses by adjusting the laser pulse energy until visible plasma luminescence and bubbles were no longer generated. The gratings had low scattering loss and could only be visualized using phase microscopy. Refractive index changes measured 0.005±0.001 to 0.01±0.001 in corneal tissue and 0.015±0.001 to 0.021±0.001 in the lenses. The gratings and refractive index changes were preserved after storing the micromachined corneas and lenses for one month. Conclusions These pilot experiments demonstrate a novel application of low-pulse-energy, MHz femtosecond lasers in modifying the refractive index of transparent ocular tissues without apparent tissue destruction. Although it remains to be verified in living tissues, the stability of this effect suggests that the observed modifications are due to long-term molecular and/or structural changes. PMID:18641284
NASA Astrophysics Data System (ADS)
Anishchenko, M. L.; Ermachenko, V. M.; Petrovskiĭ, V. N.; Protsenko, E. D.
1989-02-01
The influence of a nonlinear absorber (methane) on the natural intensity fluctuations in an He-Ne laser (λ = 3.39 μm) emitting two linearly and orthogonally polarized modes with a controlled intermode interaction was studied experimentally and theoretically for the first time. It was found that an intracavity methane cell increases appreciably the influence of the fluctuation sources on the natural intensity fluctuations.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Paranin, V. D.
In work we investigated yttrium iron garnet epitaxial films with a thickness of 10 µm and 55 µm which were grown on the surface of garnet substrate. Using the polarizing microscopy method the branching domain structure of films was shown with the period of domains 21.5 µm and 42.5 µm. Disappearance of domains at presence of an external magnetic field up to 100 Oe was noted. The optical transmission of films for the polarized beam of HeNe laser is investigated and zero diffraction order and odd diffraction rings orders were shown. Interconnection of the period of chaotically oriented domains with angles of axially symmetricmore » diffraction rings orders was shown. Diffraction patterns at various longitudinal magnetic fields are investigated. Disappearance of odd diffraction orders and increasing in intensity of zero diffraction order were fixed. Optical transmission of epitaxial films was measured in range of 500 - 900 nm.« less
International Comparison of Methane-Stabilized He-Ne Lasers
NASA Astrophysics Data System (ADS)
Koshelyaevskii, N. B.; Oboukhov, A.; Tatarenkov, V. M.; Titov, A. N.; Chartier, J.-M.; Felder, R.
1981-01-01
Two portable methane-stabilized lasers designed at BIPM have been compared with a type a stationary Soviet device developed in VNIIFTRI1. This comparison is one of a series aimed at establishing the coherence of laser wavelength and frequency measurements throughout the world and took place in June 1979. The VNIIFTRI and BIPM lasers using different methods of stabilization, have different optical and mechanical designs and laser tubes. The results of previous measurements, made in VNIIFTRI, of the most important frequency shifts for Soviet lasers together with a method of reproducing their frequency which leads to a precision of 1.10-12 are also presented.
Frequency noise properties of lasers for interferometry in nanometrology.
Hrabina, Jan; Lazar, Josef; Holá, Miroslava; Cíp, Ondřej
2013-02-07
In this contribution we focus on laser frequency noise properties and their influence on the interferometric displacement measurements. A setup for measurement of laser frequency noise is proposed and tested together with simultaneous measurement of fluctuations in displacement in the Michelson interferometer. Several laser sources, including traditional He-Ne and solid-state lasers, and their noise properties are evaluated and compared. The contribution of the laser frequency noise to the displacement measurement is discussed in the context of other sources of uncertainty associated with the interferometric setup, such as, mechanics, resolution of analog-to-digital conversion, frequency bandwidth of the detection chain, and variations of the refractive index of air.
Red-band holographic storage in azo dye sensitized by noncoherent light.
Wu, P; Chen, W; Gong, X; Zhang, G; Tang, G
1996-03-15
Biphoton holographic storage recorded with 633-nm He-Ne beams has been investigated in Methyl Yellowdoped polystyrene film sensitized by weak noncoherent light from a low-pressure Hg lamp. It is demonstrated that the holography in the sample is erasable without fading. The dynamic behavior of the hologram is dependent on the cis-trans isomerization by noncoherent light and 633-nm beams and photoinduced heat.
Laser Doppler velocimetry for continuous flow solar-pumped iodine laser system
NASA Technical Reports Server (NTRS)
Tabibi, Bagher M.; Lee, Ja H.
1991-01-01
A laser Doppler velocimetry (LDV) system was employed to measure the flow velocity profile of iodide vapor inside laser tubes of 36 mm ID and 20 mm ID. The LDV, which was operated in the forward scatter mode used a low power (15 mW) He-Ne laser beam. Velocity ranges from 1 m/s was measured to within one percent accuracy. The flow velocity profile across the laser tube was measured and the intensity of turbulence was determined. The flow of iodide inside the laser tube demonstrated a mixture of both turbulence and laminar flow. The flowmeter used for the laser system previously was calibrated with the LDV and found to be in good agreement.
Treatment of TMJDS with helium-neon laser beam irradiation on the acupoints
NASA Astrophysics Data System (ADS)
Li, Ping
1993-03-01
Through He-NE laser stimulation of acupuncture points, we treated and observed 50 cases of Temporomandibular Joint Dysfunction Syndrome (TMJDS). The results proved that this treatment was very effective for relieving the patient's pain. In cases which had structural disturbances and organic damage such as limitation of mouth-opening and joint clink, there was less improvement of symptoms and no relief for joint clink.
Youssef, Doaa; El-Ghandoor, Hatem; Kandel, Hamed; El-Azab, Jala; Hassab-Elnaby, Salah
2017-06-28
The application of He-Ne laser technologies for description of articular cartilage degeneration, one of the most common diseases worldwide, is an innovative usage of these technologies used primarily in material engineering. Plain radiography and magnetic resonance imaging are insufficient to allow the early assessment of the disease. As surface roughness of articular cartilage is an important indicator of articular cartilage degeneration progress, a safe and noncontact technique based on laser speckle image to estimate the surface roughness is provided. This speckle image from the articular cartilage surface, when illuminated by laser beam, gives very important information about the physical properties of the surface. An experimental setup using a low power He-Ne laser and a high-resolution digital camera was implemented to obtain speckle images of ten bovine articular cartilage specimens prepared for different average roughness values. Texture analysis method based on gray-level co-occurrence matrix (GLCM) analyzed on the captured speckle images is used to characterize the surface roughness of the specimens depending on the computation of Haralick's texture features. In conclusion, this promising method can accurately estimate the surface roughness of articular cartilage even for early signs of degeneration. The method is effective for estimation of average surface roughness values ranging from 0.09 µm to 2.51 µm with an accuracy of 0.03 µm.
El-Ghandoor, Hatem; Kandel, Hamed; El-Azab, Jala; Hassab-Elnaby, Salah
2017-01-01
The application of He-Ne laser technologies for description of articular cartilage degeneration, one of the most common diseases worldwide, is an innovative usage of these technologies used primarily in material engineering. Plain radiography and magnetic resonance imaging are insufficient to allow the early assessment of the disease. As surface roughness of articular cartilage is an important indicator of articular cartilage degeneration progress, a safe and noncontact technique based on laser speckle image to estimate the surface roughness is provided. This speckle image from the articular cartilage surface, when illuminated by laser beam, gives very important information about the physical properties of the surface. An experimental setup using a low power He-Ne laser and a high-resolution digital camera was implemented to obtain speckle images of ten bovine articular cartilage specimens prepared for different average roughness values. Texture analysis method based on gray-level co-occurrence matrix (GLCM) analyzed on the captured speckle images is used to characterize the surface roughness of the specimens depending on the computation of Haralick’s texture features. In conclusion, this promising method can accurately estimate the surface roughness of articular cartilage even for early signs of degeneration. The method is effective for estimation of average surface roughness values ranging from 0.09 µm to 2.51 µm with an accuracy of 0.03 µm. PMID:28773080
NASA Technical Reports Server (NTRS)
Nguyen, Quang-Viet
2001-01-01
Concerns about damaging the Earth's ozone layer as a result of high levels of nitrogen oxides (known collectively as NOx) from high-altitude, high-speed aircraft have prompted the study of lean premixed prevaporized (LPP) combustion in aircraft engines. LPP combustion reduces NOx emissions principally by reducing the peak flame temperatures inside an engine. Recent advances in LPP technologies have realized exceptional reductions in pollutant emissions (single-digit ppm NOx for example). However, LPP combustion also presents major challenges: combustion instability and dynamic coupling effects between fluctuations in heat-release rate, dynamic pressure, and fuel pressure. These challenges are formidable and can literally shake an engine apart if uncontrolled. To better understand this phenomenon so that it can be controlled, we obtained real-time laser absorption measurements of the fuel vapor concentration (and equivalence ratio) simultaneously with the dynamic pressure, flame luminosity, and time-averaged gaseous emissions measurements in a research-type jet-A-fueled LPP combustor. The measurements were obtained in NASA Glenn Research Center's CE-5B optically accessible flame tube facility. The CE-5B facility provides inlet air temperatures and pressures similar to the actual operating conditions of real aircraft engines. The laser absorption measurements were performed using an infrared 3.39 micron HeNe laser in conjunction with a visible HeNe laser for liquid droplet scattering compensation.
Synthesis and photoluminescent and nonlinear optical properties of manganese doped ZnS nanoparticles
NASA Astrophysics Data System (ADS)
Nazerdeylami, Somayeh; Saievar-Iranizad, Esmaiel; Dehghani, Zahra; Molaei, Mehdi
2011-01-01
In this work we synthesized ZnS:Mn 2+ nanoparticles by chemical method using PVP (polyvinylpyrrolidone) as a capping agent in aqueous solution. The structure and optical properties of the resultant product were characterized using UV-vis optical spectroscopy, X-ray diffraction (XRD), photoluminescence (PL) and z-scan techniques. UV-vis spectra for all samples showed an excitonic peak at around 292 nm, indicating that concentration of Mn 2+ ions does not alter the band gap of nanoparticles. XRD patterns showed that the ZnS:Mn 2+ nanoparticles have zinc blende structure with the average crystalline sizes of about 2 nm. The room temperature photoluminescence (PL) spectrum of ZnS:Mn 2+ exhibited an orange-red emission at 594 nm due to the 4T 1- 6A 1 transition in Mn 2+. The PL intensity increased with increase in the Mn 2+ ion concentration. The second-order nonlinear optical properties of nanoparticles were studied using a continuous-wave (CW) He-Ne laser by z-scan technique. The nonlinear refractive indices of nanoparticles were in the order of 10 -8 cm 2/W with negative sign and the nonlinear absorption indices of these nanoparticles were obtained to be about 10 -3 cm/W with positive sign.
Mode Behavior in Ultralarge Ring Lasers
NASA Astrophysics Data System (ADS)
Hurst, Robert B.; Dunn, Robert W.; Schreiber, K. Ulrich; Thirkettle, Robert J.; MacDonald, Graeme K.
2004-04-01
Contrary to expectations based on mode spacing, single-mode operation in very large He-Ne ring lasers may be achieved at intracavity power levels up to ~0.15 times the saturation intensity for the He-Ne transition. Homogeneous line broadening at a high total gas pressure of 4-6 Torr allows a single-peaked gain profile that suppresses closely spaced multiple modes. At startup, decay of initial multiple modes may take tens of seconds. The single remaining mode in each direction persists metastably as the cavity is detuned by many times the mode frequency spacing. A theoretical explanation requires the gain profile to be concave down and to satisfy an inequality related to slope and saturation at the operating frequency. Calculated metastable frequency ranges are greater than 150 MHz at 6 Torr and depend strongly on pressure. Examples of unusual stable mode configurations are shown, with differently numbered modes in the two directions and with multiple modes at a spacing of ~100 MHz.
Mode behavior in ultralarge ring lasers.
Hurst, Robert B; Dunn, Robert W; Schreiber, K Ulrich; Thirkettle, Robert J; MacDonald, Graeme K
2004-04-10
Contrary to expectations based on mode spacing, single-mode operation in very large He-Ne ring lasers may be achieved at intracavity power levels up to approximately0.15 times the saturation intensity for the He-Ne transition. Homogeneous line broadening at a high total gas pressure of 4-6 Torr allows a single-peaked gain profile that suppresses closely spaced multiple modes. At startup, decay of initial multiple modes may take tens of seconds. The single remaining mode in each direction persists metastably as the cavity is detuned by many times the mode frequency spacing. A theoretical explanation requires the gain profile to be concave down and to satisfy an inequality related to slope and saturation at the operating frequency. Calculated metastable frequency ranges are > 150 MHz at 6 Torr and depend strongly on pressure. Examples of unusual stable mode configurations are shown, with differently numbered modes in the two directions and with multiple modes at a spacing of approximately 100 MHz.
Low-level laser therapy on MCF-7 cells: a micro-Fourier transform infrared spectroscopy study.
Magrini, Taciana D; dos Santos, Nathalia Villa; Milazzotto, Marcella Pecora; Cerchiaro, Giselle; da Silva Martinho, Herculano
2012-10-01
Low-level laser therapy (LLLT) is an emerging therapeutic approach for several clinical conditions. The clinical effects induced by LLLT presumably scale from photobiostimulation/photobioinhibition at the cellular level to the molecular level. The detailed mechanism underlying this effect remains unknown. This study quantifies some relevant aspects of LLLT related to molecular and cellular variations. Malignant breast cells (MCF-7) were exposed to spatially filtered light from a He-Ne laser (633 nm) with fluences of 5, 28.8, and 1000 mJ/cm². The cell viability was evaluated by optical microscopy using the Trypan Blue viability test. The micro-Fourier transform infrared technique was employed to obtain the vibrational spectra of each experimental group (control and irradiated) and identify the relevant biochemical alterations that occurred due to the process. It was observed that the red light influenced the RNA, phosphate, and serine/threonine/tyrosine bands. We found that light can influence cell metabolism depending on the laser fluence. For 5 mJ/cm², MCF-7 cells suffer bioinhibition with decreased metabolic rates. In contrast, for the 1 J/cm² laser fluence, cells present biostimulation accompanied by a metabolic rate elevation. Surprisingly, at the intermediate fluence, 28.8 mJ/cm², the metabolic rate is increased despite the absence of proliferative results. The data were interpreted within the retrograde signaling pathway mechanism activated with light irradiation.
Calibration of Thomson scattering system on VEST
NASA Astrophysics Data System (ADS)
Kim, Y.-G.; Lee, J.-H.; Kim, D.; Yoo, M.-G.; Lee, H.; Hwang, Y. S.; Na, Y.-S.
2017-12-01
The Thomson scattering system has been recently installed on Versatile Experiment Spherical Torus (VEST) to measure the electron temperature and the density of the core plasmas. Since the calibration of the system is required for the accurate measurement of these parameters, a polychromator and the system efficiency are calibrated. The bias voltage of the detector is optimized and the relative responsivity of the polychromator is measured to analyse the spectral broadening. The tendency of decreasing responsivity because of the ambient temperature change is addressed together. The efficiencies of the alignments using HeNe laser and Nd:YAG laser are compared. After the alignment using Rayleigh scattering, it is improved ~ 7 times while the peak signal of the stray light is decreased. To evaluate the efficiencies of the alignment using HeNe laser, it is compared with the efficiency of the fine alignment by Rayleigh scattering. After absolute calibration is done, the Thomson scattering signal is estimated theoretically. The Bayesian analysis is tried using the synthetic data, and the results show that the input temperature and the density are inside the contour of the 90% confident level. The calibrated Thomson scattering system will provide the meaningful information of the core plasma of the VEST.
Investigation of laser holographic interferometric techniques for structure inspection
NASA Technical Reports Server (NTRS)
Chu, W. P.
1973-01-01
The application of laser holographic interferometric techniques for nondestructive inspection of material structures commonly used in aerospace works is investigated. Two types of structures, composite plate and solid fuel rocket engine motor casing, were examined. In conducting the experiments, both CW HeNe gas lasers and Q-switched ruby lasers were used as light sources for holographic recording setups. Different stressing schemes were investigated as to their effectiveness in generating maximum deformation at regions of structural weakness such as flaws and disbonds. Experimental results on stressing schemes such as thermal stressing, pressurized stressing, transducer excitation, and mechanical impact are presented and evaluated.
Microprocessor-controlled laser tracker for atmospheric sensing
NASA Technical Reports Server (NTRS)
Johnson, R. A.; Webster, C. R.; Menzies, R. T.
1985-01-01
An optical tracking system comprising a visible HeNe laser, an imaging detector, and a microprocessor-controlled mirror, has been designed to track a moving retroreflector located up to 500 m away from an atmospheric instrument and simultaneously direct spectrally tunable infrared laser radiation to the retroreflector for double-ended, long-path absorption measurements of atmospheric species. The tracker has been tested during the recent flight of a balloon-borne tunable diode laser absorption spectrometer which monitors the concentrations of stratospheric species within a volume defined by a 0.14-m-diameter retroreflector lowered 500 m below the instrument gondola.
NASA Astrophysics Data System (ADS)
Motrich, A. V.; Ushenko, O. G.
2018-01-01
The results of statistical dependence and correlation structures of two-dimensional Mueller matrix elements in various spectral regions of laser radiation by changes in the distribution of orientations of optical axes and birefringence of protein crystals. Namely, a two-wave ("red-blue") approach - layer of biological tissues irradiated by He-Ne laser (λ1 = 0,63μm ) and He-Cd laser (λ1 = 0,41μm )was used Conducted analysis of polarimetric sensitivity was made, a state of polarization points that contain volumetric structures of biological objects to spectral region of laser radiation was detected.
To what extent is coherence lost in tissue?
NASA Astrophysics Data System (ADS)
Hode, Tomas; Jenkins, Peter; Jordison, Stefan; Hode, Lars
2011-03-01
In a series of experiments we investigated the extent to which coherence is preserved in tissue. We investigated whether the decrease in coherence length is dependent upon the coherence length of the illuminating light and possibly also if the light is polarized. We compared highly coherent light from a HeNe laser, and less coherent light from a semiconductor laser, in scattering media such as raw ground beef. We studied the laser speckle contrast after passing through 1 - 2 cm of meat. The conclusion is that the laser light is still coherent enough to form laser speckles after passing through a 2 cm thickness of meat.
Whole-Field Experimental Stress Analysis Using Laser Speckle Interferometry.
1981-02-14
region. UNCLASSIFIED SECURITY CLASSIFICATtON OF THIS PAGE(When Data Entrerd) ACKNOWLEDGMENTS The author expresses appreciation to Mr. J. A. Schaeffel ...for Aperture Analysis of Interferograms A system for analyzing interferograms developed by Schaeffel [6] was used to analyze selected areas on the...found in Schaeffel [6]. A Spectra Physics Model 125 He-Ne laser was used as the light source with the beam expanded through a Spectra Physics model 332
Bibliography of Soviet Laser Developments, Number 87, January-February 1987
1987-12-29
laser. OPMPA, no. 1, 1987, 58-59. 84. Sukhanov , 1.1.; Troitskiy, Yu.V.; Yakushkin, S.V. 0 Investigation of a He-Ne laser, generating a beam with a...2Ye498). * 519. Shelekhov, N.S.; Sukhanov , V.I.; Solomatin, Yu.V.;Ashcheulov, Yu.V. (GOI). Investigation of the possibility of obtaining specimens of...G 46,49 SOBOLEV V B 57 SUETIN N V 26 TIMASHOV A V 11 SOCHIVKIN G M 87 SUKHANOV I 1 11 TIMASHOVA L N 60 SOKOLOV A V 107 SUKHANOV V 1 61 TIMERKAYEV B A
Frequency Noise Properties of Lasers for Interferometry in Nanometrology
Hrabina, Jan; Lazar, Josef; Holá, Miroslava; Číp, Ondřej
2013-01-01
In this contribution we focus on laser frequency noise properties and their influence on the interferometric displacement measurements. A setup for measurement of laser frequency noise is proposed and tested together with simultaneous measurement of fluctuations in displacement in the Michelson interferometer. Several laser sources, including traditional He-Ne and solid-state lasers, and their noise properties are evaluated and compared. The contribution of the laser frequency noise to the displacement measurement is discussed in the context of other sources of uncertainty associated with the interferometric setup, such as, mechanics, resolution of analog-to-digital conversion, frequency bandwidth of the detection chain, and variations of the refractive index of air. PMID:23435049
Clinical effectiveness of low-level laser treatment on peripheral somatosensory neuropathy.
Fallah, Alireza; Mirzaei, Alireza; Gutknecht, Norbert; Demneh, Amir Saberi
2017-04-01
Peripheral sensory neuropathy treatment is one of the common treatment problems and causes morbidity and mortality in people suffering from that. Although treatment depends on the underlying cause of the condition, nevertheless, in some cases, there is no cure for it, and it requires palliative and symptomatic treatment. In laboratory studies, low-level laser has been effective in the nerves protection and restoration. The aim of this article is to investigate the clinical efficacy of low-level laser on improvement of the peripheral somatosensory neuropathy. Search in the articles published up to 30 October 2015 (full text and abstracts) in databases PubMed (Medline), Cochrane library, Physiotherapy Evidence Database was performed. The studies of low-level laser trials on patients with peripheral neuropathy were carried out and evaluated in terms of the exclusion criteria. There are 35 articles among which 10 articles had the intended and required criteria. 1, 3, and 6 articles study the patients with diabetes, neuropathy caused by trauma, and carpal tunnel syndrome, respectively. In six studies, laser led to a reduction in sensory impairment and improvement of the physiological function of the sensory nerves. In these articles, lasers (Diode, GaAlAs, He-Ne) had wavelength range 660-860 nm, radiation power 20-250 mW, energy density 0.45-70 J/cm 2 . The intervention sessions range was 6-21 times and patient follow-up was 0-6 months. According to the results of these studies, low-level laser therapy can improve sensory function in patients with peripheral somatosensory neuropathy, although little research have not been done, laser treatment regimens are varied and do not recommend a specific treatment protocol. It seems it requires more research to sum up better, particularly in relation to diabetes.
Hielscher, Andreas H.; Mourant, Judith R.; Bigio, Irving J.
2000-01-01
An apparatus and method for recording spatially dependent intensity patterns of polarized light that is diffusely backscattered from highly scattering media are described. These intensity patterns can be used to differentiate different turbid media, such as polystyrene-sphere and biological-cell suspensions. Polarized light from a He-Ne laser (.lambda.=543 nm) is focused onto the surface of the scattering medium, and a surface area of approximately 4.times.4 cm centered on the light input point is imaged through polarization analysis optics onto a CCD camera. A variety of intensity patterns may be observed by varying the polarization state of the incident laser light and changing the analyzer configuration to detect different polarization components of the backscattered light. Experimental results for polystyrene-sphere and Intralipid suspensions demonstrate that the radial and azimuthal variations of the observed pattern depend on the concentration, size, and anisotropy factor, g, of the particles constituting the scattering medium. Measurements performed on biological cell suspensions show that intensity patterns can be used to differentiate between suspensions of cancerous and non-cancerous cells. Introduction of the Mueller-matrix for diffusely backscattered light, permits the selection of a subset of measurements which comprehensively describes the optical properties of backscattering media.
Diode-pumped large-aperture Nd:YAG slab amplifier for high energy nanosecond pulse laser
NASA Astrophysics Data System (ADS)
Guo, Guangyan; Chen, Yanzhong; He, Jianguo; Lang, Ye; Lin, Weiran; Tang, Xiongxin; Zhang, Hongbo; Kang, Zhijun; Fan, Zhongwei
2017-10-01
A high gain, low thermal-induced wavefront distortion, laser diode-pumped Nd: YAG slab amplifier is demonstrated with its active media dimensions of 7 mm ×35 mm ×138.2 mm. Under the 200 Hz, 1440 W pulse pumping condition while no seed light to amplify, the thermal induced wavefront aberration of a He-Ne probe passing through the gain meUdium is 0.165 λ@633 nm (RMS). The amplifier shows stable aberration character with two major low-order terms, defocus and 0° astigmatism. The fluorescence distribution, stored energy, and small-signal gain of the amplifier are measured and have a good agreement with the calculated results. In the amplifier, the fluorescence is uniformly distributed and the maximum stored energy of 3.2 J can be achieved with a plane-concave cavity at 200 Hz pump repetition frequency. For a repetition frequency of 200 Hz, 25 μJ injection polarized seed-light and 1440 W pump power, the small signal gain reaches 9.45. The amplifier has been successfully employed in a 200 Hz, 5 J, MOPA system with 1.7 times diffraction limited output.
NASA Astrophysics Data System (ADS)
Vediyappan, Sivasubramani; Arumugam, Raja; Pichan, Karuppasamy; Kasthuri, Ramachandran; Muthu, Senthil Pandian; Perumal, Ramasamy
2017-12-01
Semi-organic nonlinear optical (NLO) 2-amino-5-nitropyridinium bromide (2A5NPBr) single crystals have been grown by slow evaporation solution technique (SEST) with the growth period of 60 days. The single-crystal XRD analysis confirms the unit cell parameters of the grown crystal. The crystallinity of grown 2A5NPBr was analyzed by powder X-ray diffraction (PXRD) measurement. The presence of functional groups of 2A5NPBr crystal was confirmed by Fourier transform infrared (FTIR) spectrum analysis. The optical transmittance of the grown crystal was analyzed by UV-Vis-NIR analysis. It shows good transparency in the visible and NIR region and it is favorable for nonlinear optical (NLO) device applications. The chemical etching study was carried out and it reveals that the grown crystal has less dislocation density. The photoconductivity study reveals that the grown crystal possesses positive photoconductive nature. The thermal stability of the crystal has been investigated by thermogravimetric (TG) and differential thermal analysis (DTA). The dielectric constant and dielectric loss as a function of frequency were measured. The electronic polarizability (α) of 2A5NPBr molecule has been calculated theoretically by different ways such as Penn analysis, Clausius-Mossotti relation, Lorentz-Lorenz equation, optical bandgap, and coupled dipole method (CDM). The obtained values of electronic polarizability (α) are in good agreement with each other. Laser damage threshold (LDT) of 2A5NPBr crystal has been measured using Nd:YAG laser with the wavelength of 1064 nm. Third-order nonlinear optical property of the grown crystal was studied by Z-scan technique using He-Ne laser of wavelength 632.8 nm.
Boyde, A; Vesely, P; Gray, C; Jones, S J
1994-01-01
Chick and rat bone-derived cells were mounted in sealed coverslip-covered chambers; individual osteoclasts (but also osteoblasts) were selected and studied at 37 degrees C using three different types of high-speed scanning confocal microscopes: (1) A Noran Tandem Scanning Microscope (TSM) was used with a low light level, cooled CCD camera for image transfer to a Noran TN8502 frame store-based image analysing computer to make time lapse movie sequences using 0.1 s exposure periods, thus losing some of the advantage of the high frame rate of the TSM. Rapid focus adjustment using computer controlled piezo drivers permitted two or more focus planes to be imaged sequentially: thus (with additional light-source shuttering) the reflection confocal image could be alternated with the phase contrast image at a different focus. Individual cells were followed for up to 5 days, suggesting no significant irradiation problem. (2) Exceptional temporal and spatial resolution is available in video rate laser confocal scanning microscopes (VRCSLMs). We used the Noran Odyssey unitary beam VRCSLM with an argon ion laser at 488 nm and acousto-optic deflection (AOD) on the line axis: this instrument is truly and adjustably confocal in the reflection mode. (3) We also used the Lasertec 1LM11 line scan instrument, with an He-Ne laser at 633 nm, and AOD for the frame scan. We discuss the technical problems and merits of the different approaches. The VRCSLMs documented rapid, real-time oscillatory motion: all the methods used show rapid net movement of organelles within bone cells. The interference reflection mode gives particularly strong contrasts in confocal instruments. Phase contrast and other interference methods used in the microscopy of living cells can be used simultaneously in the TSM.
Influence of beam shape on in-vitro cellular transformations in human skin fibroblasts
NASA Astrophysics Data System (ADS)
Mthunzi, Patience; Forbes, Andrew; Hawkins, Denise; Abrahamse, Heidi; Karsten, Aletta E.
2005-08-01
A variety of strategies have been utilised for prevention and treatment of chronic wounds such as leg ulcers, diabetic foot ulcers and pressure sores1. Low Level Laser Therapy (LLLT) has been reported to be an invaluable tool in the enhancement of wound healing through stimulating cell proliferation, accelerating collagen synthesis and increasing ATP synthesis in mitochondria to name but a few2. This study focused on an in-vitro analysis of the cellular responses induced by treatment with three different laser beam profiles namely, the Gaussian (G), Super Gaussian (SG) and Truncated Gaussian (TG), on normal wounded irradiated (WI) and wounded non-irradiated (WNI) human skin fibroblast cells (WS1), to test their influence in wound healing at 632.8 nm using a helium neon (HeNe) laser. For each beam profile, measurements were made using average energy densities over the sample ranging from 0.2 to 1 J, with single exposures on normal wounded cells. The cells were subjected to different post irradiation incubation periods, ranging from 0 to 24 hours to evaluate the duration (time) dependent effects resulting from laser irradiation. The promoted cellular alterations were measured by increase in cell viability, cell proliferation and cytotoxicity. The results obtained showed that treatment with the G compared to the SG and TG beams resulted in a marked increase in cell viability and proliferation. The data also showed that when cells undergo laser irradiation some cellular processes are driven by the peak energy density rather than the energy of the laser beam. We show that there exist threshold values for damage, and suggest optimal operating regimes for laser based wound healing.
Sensitive Carbohydrate Detection using Surface Enhanced Raman Tagging
Vangala, Karthikeshwar; Yanney, Michael; Hsiao, Cheng-Te; Wu, Wells W.; Shen, Rong-Fong; Zou, Sige; Sygula, Andrzej; Zhang, Dongmao
2010-01-01
Glycomic analysis is an increasingly important field in biological and biomedical research as glycosylation is one of the most important protein post-translational modifications. We have developed a new technique to detect carbohydrates using surface enhanced Raman spectroscopy (SERS) by designing and applying a Rhodamine B derivative as the SERS tag. Using a reductive amination reaction, the Rhodamine-based tag (RT) was successfully conjugated to three model carbohydrates (glucose, lactose and glucuronic acid). SERS detection limits obtained with 632 nm HeNe laser were ~1 nM in concentration for all the RT-carbohydrate conjugates and ~10 fmol in total sample consumption. The dynamic range of the SERS method is about 4 orders of magnitude, spanning from 1 nM to 5 µM. Ratiometric SERS quantification using isotope-substituted SERS internal references also allows comparative quantifications of carbohydrates labeled with RT and deuterium/hydrogen substituted RT tags, respectively. In addition to enhancing the SERS detection of the tagged carbohydrates, the Rhodamine tagging facilitates fluorescence and mass spectrometric detection of carbohydrates. Current fluorescence sensitivity of RT-carbohydrates is ~ 3 nM in concentration while the mass spectrometry (MS) sensitivity is about 1 fmol that was achieved with linear ion trap electrospray ionization (ESI)-MS instrument. Potential applications that take advantage of the high SERS, fluorescence and MS sensitivity of this SERS tagging strategy are discussed for practical glycomic analysis where carbohydrates may be quantified with a fluorescence and SERS technique, and then identified with ESI-MS techniques. PMID:21082777
A Study of Brownian Motion Using Light Scattering
ERIC Educational Resources Information Center
Clark, Noel A.; Lunacek, Joseph H.
1969-01-01
Describes an apparatus designed to investigate molecular motion by means of light scattering. Light from a He-Ne laser is focused into a cell containing a suspension of polystyrene spheres. The scattered light, collected on the photosurface of a photomultiplier tube, is analyzed. The apparatus won first prize in Demonstration Lecture Apparatus in…
NASA Astrophysics Data System (ADS)
Pawde, S. M.; Parab, Sanmesh S.
2008-05-01
Polystyrene (PS) films are used in packaging and biomedical applications because of their transparency and good environmental properties. The present investigation is centered on the antifungal and antibacterial activities involved in the film surface. Subsequently, microbial formations were immobilized on the modified PS films. Living microorganisms such as bacteria and yeast were used. Untreated PS films show very fast rate of growth of bacteria within few hours. The study involves developments of polymer surfaces with bacterial growth and further studies after giving antibacterial treatment such as plasma treatment. Major emphasis has been given to study the effect of various parameters which can affect the performance of the improved material. Films were prepared by two methods: plasma treatment under vacuum and under ongoing He-Ne laser source. The parameters such as (1) surface area by contact angle measurements, (2) quality of material before and after treatment by SEM and FTIR spectra and (3) material characterization by UV-vis spectra were studied. It was observed that plasma treatment of the PS material for different processing time improved the surface properties of PS films.
Antares alignment gimbal positioner
NASA Astrophysics Data System (ADS)
Day, R. D.; Viswanathan, V. K.; Saxman, A. C.; Lujan, R. E.; Woodfin, W. C.; Sweatt, W. C.
Antares is a 24-beam 40-TW carbon dioxide (CO2) laser fusion system currently under construction at the Los Alamos National Laboratory. The Antares alignment gimbal positioner (AGP) is an optomechanical instrument that will be used for target alignment and alignment of the 24 laser beams, as well as beam quality assessments. The AGP will be capable of providing pointing, focusing, an wavefront optical path difference, as well as aberration information at both helium neon (He-Ne) and CO2 wavelengths. It is designed to allow the laser beams to be aligned to any position within a 1 cm cube to a tolerance of 10 micrometers.
He-Ne laser treatment for 16 cases of nonspecific edema
NASA Astrophysics Data System (ADS)
Xia, Wenlou; Liu, Sixian; Cao, Guangyi; Chen, Zhifu; Zhang, Haishui; Wei, Wei; Xia, Xinshe; Sia, Guangyu
1993-03-01
Nonspecific edema is a syndrome which is caused by a metabolism disorder of sodium and water. The people who suffer with this are mostly women about 25 - 50 years old. When it happens periodic edema, abdominal distension acratia, and obesity accompany the disease. Through several means of examination, no organic disease was found in the heart, liver, or kidney. Now 16 edema cases have been irradiated with laser and the result is satisfactory. The results are reported in this paper.
Evaluation of the analgesic effect of low-power optical radiation in acute inflammatory process
NASA Astrophysics Data System (ADS)
Ferreira, Denise M.; Zangaro, Renato A.; Cury, Yara; Frigo, Lucio; Barbosa, Daniella G.; da Silva Melo, Milene; Munin, Egberto
2004-07-01
Many research works have explored the use of the low power laser as a tool for the control of inflammatory processes. The anti-inflammatory effect of low power optical radiation and its ability to induce analgesia has been reported for different experimental conditions. Many published works are very qualitative in nature. In this work the action of low power laser radiation on acute inflammatory process is evaluated. The time evolution of rat paw edema and pain induced by carrageenan was experimentally monitored. A 632.8 nm He-Ne laser was used for the treatment. The laser treatment, at a dosage of 2,5 J/cm2, was applied at the first, second and third hour after the induction of the inflammation. A hydroplethysmometer was used for the evaluation of the inflammation. The measurement of pain sensitivity was performed according to the method described by Randall and Selito, (1957). The laser treatment was capable of inhibiting the carrageenan-induced hyperalgesia by 49% (p<0,001) at the second hour after the induction, as compared to the non-treated group. At the fourth hour (peak of the carrageenan action on hyperalgesia) and at the sixth hour, the achieved inhibition was 49% (p<0,001) and 61% (p<0,001), respectively. In the treated groups, the edema evolution was inhibited by 38% (p<0,01), at the second hour after induction, as compared to the non-treated groups. At the fourth hour (peak of the carrageenan action on leakage) and at sixth hour the achieved inhibition was 35% (p<0,01) and 30% (p<0,05) respectively.
Multi-image acquisition-based distance sensor using agile laser spot beam.
Riza, Nabeel A; Amin, M Junaid
2014-09-01
We present a novel laser-based distance measurement technique that uses multiple-image-based spatial processing to enable distance measurements. Compared with the first-generation distance sensor using spatial processing, the modified sensor is no longer hindered by the classic Rayleigh axial resolution limit for the propagating laser beam at its minimum beam waist location. The proposed high-resolution distance sensor design uses an electronically controlled variable focus lens (ECVFL) in combination with an optical imaging device, such as a charged-coupled device (CCD), to produce and capture different laser spot size images on a target with these beam spot sizes different from the minimal spot size possible at this target distance. By exploiting the unique relationship of the target located spot sizes with the varying ECVFL focal length for each target distance, the proposed distance sensor can compute the target distance with a distance measurement resolution better than the axial resolution via the Rayleigh resolution criterion. Using a 30 mW 633 nm He-Ne laser coupled with an electromagnetically actuated liquid ECVFL, along with a 20 cm focal length bias lens, and using five spot images captured per target position by a CCD-based Nikon camera, a proof-of-concept proposed distance sensor is successfully implemented in the laboratory over target ranges from 10 to 100 cm with a demonstrated sub-cm axial resolution, which is better than the axial Rayleigh resolution limit at these target distances. Applications for the proposed potentially cost-effective distance sensor are diverse and include industrial inspection and measurement and 3D object shape mapping and imaging.
Progress in coherent lithography using table-top extreme ultraviolet lasers
NASA Astrophysics Data System (ADS)
Li, Wei
Nanotechnology has drawn a wide variety of attention as interesting phenomena occurs when the dimension of the structures is in the nanometer scale. The particular characteristics of nanoscale structures had enabled new applications in different fields in science and technology. Our capability to fabricate these nanostructures routinely for sure will impact the advancement of nanoscience. Apart from the high volume manufacturing in semiconductor industry, a small-scale but reliable nanofabrication tool can dramatically help the research in the field of nanotechnology. This dissertation describes alternative extreme ultraviolet (EUV) lithography techniques which combine table-top EUV laser and various cost-effective imaging strategies. For each technique, numerical simulations, system design, experiment result and its analysis will be presented. In chapter II, a brief review of the main characteristics of table-top EUV lasers will be addressed concentrating on its high power and large coherence radius that enable the lithography application described herein. The development of a Talbot EUV lithography system which is capable of printing 50nm half pitch nanopatterns will be illustrated in chapter III. A detailed discussion of its resolution limit will be presented followed by the development of X-Y-Z positioning stage, the fabrication protocol for diffractive EUV mask, and the pattern transfer using self- developed ion beam etching, and the dose control unit. In addition, this dissertation demonstrated the capability to fabricate functional periodic nanostructures using Talbot EUV lithography. After that, resolution enhancement techniques like multiple exposure, displacement Talbot EUV lithography, fractional Talbot EUV lithography, and Talbot lithography using 18.9nm amplified spontaneous emission laser will be demonstrated. Chapter IV will describe a hybrid EUV lithography which combines the Talbot imaging and interference lithography rendering a high resolution interference pattern whose lattice is modified by a custom designed Talbot mask. In other words, this method enables filling the arbitrary Talbot cell with ultra-fine interference nanofeatures. Detailed optics modeling, system design and experiment results using He-Ne laser and table top EUV laser are included. The last part of chapter IV will analyze its exclusive advantages over traditional Talbot or interference lithography.
Value of low-power lasers in the treatment of symptomatic spondilosis
NASA Astrophysics Data System (ADS)
Antipa, Ciprian; Moldoveanu, Vladimir; Rusca, Nicolae; Bruckner, Ion I.; Vlaiculescu, Mihaela; Ionescu, Elena; Vasiliu, Virgil V.
1998-07-01
Low power laser (LPL) use in the treatment of arthrosic rheumatism is well known. From a total number of 280 patients with symptomatic spondylosis we finally selected 66, with changes of the EEG color mapping. These investigation was done before and after treatment in order to obtain an objective method to appreciate these results. The patients were splitted in laser group (36 patients treated with HeNe and IR diode LPL) and control group (30 patients treated with placebo laser). The results indicate a significant improvement of the symptoms at 77% of the patients from laser group as compared with 33% favorable results at the placebo laser. The EEG mapping improved at 58% patients from laser group as compared with 20% at the control group.
Gas-laser behavior in a low-gravity environment
NASA Technical Reports Server (NTRS)
Owen, R. B.
1981-01-01
In connection with several experiments proposed for flight on the Space Shuttle, which involve the use of gas lasers, the behavior of a He-Ne laser in a low-gravity environment has been studied theoretically and experimentally in a series of flight tests using a low-gravity-simulation aircraft. No fluctuation in laser output above the noise level of the meter (1 part in 1000 for 1 hr) was observed during the low-gravity portion of the flight tests. The laser output gradually increased by 1.4% during a 1.5-hr test; at no time were rapid variations observed in the laser output. A maximum laser instability of 1 part in 100 was observed during forty low-gravity parabolic maneuvers. The beam remained Gaussian throughout the tests and no lobe patterns were observed.
Optical Constants of Crystallized TiO2 Coatings Prepared by Sol-Gel Process
Wang, Xiaodong; Wu, Guangming; Zhou, Bin; Shen, Jun
2013-01-01
Titanium oxide coatings have been deposited by the sol-gel dip-coating method. Crystallization of titanium oxide coatings was then achieved through thermal annealing at temperatures above 400 °C. The structural properties and surface morphology of the crystallized coatings were studied by micro-Raman spectroscopy and atomic force microscopy, respectively. Characterization technique, based on least-square fitting to the measured reflectance and transmittance spectra, is used to determine the refractive indices of the crystallized TiO2 coatings. The stability of the synthesized sol was also investigated by dynamic light scattering particle size analyzer. The influence of the thermal annealing on the optical properties was then discussed. The increase in refractive index with high temperature thermal annealing process was observed, obtaining refractive index values from 1.98 to 2.57 at He-Ne laser wavelength of 633 nm. The Raman spectroscopy and atomic force microscopy studies indicate that the index variation is due to the changes in crystalline phase, density, and morphology during thermal annealing. PMID:28811410
Optical Constants of Crystallized TiO₂ Coatings Prepared by Sol-Gel Process.
Wang, Xiaodong; Wu, Guangming; Zhou, Bin; Shen, Jun
2013-07-12
Titanium oxide coatings have been deposited by the sol-gel dip-coating method. Crystallization of titanium oxide coatings was then achieved through thermal annealing at temperatures above 400 °C. The structural properties and surface morphology of the crystallized coatings were studied by micro-Raman spectroscopy and atomic force microscopy, respectively. Characterization technique, based on least-square fitting to the measured reflectance and transmittance spectra, is used to determine the refractive indices of the crystallized TiO₂ coatings. The stability of the synthesized sol was also investigated by dynamic light scattering particle size analyzer. The influence of the thermal annealing on the optical properties was then discussed. The increase in refractive index with high temperature thermal annealing process was observed, obtaining refractive index values from 1.98 to 2.57 at He-Ne laser wavelength of 633 nm. The Raman spectroscopy and atomic force microscopy studies indicate that the index variation is due to the changes in crystalline phase, density, and morphology during thermal annealing.
NASA Astrophysics Data System (ADS)
Kumara, K.; Shetty, T. C. S.; Patil, P. S.; Dharmaprakash, S. M.
2018-05-01
The present study investigates linear and third order nonlinear optical (TNLO) properties of nitrogen incorporated graphene oxide (NGO). A simple pyrolysis method is followed to obtain NGO powder which is soluble in polar aprotic and protic solvents. The normalized emission intensity of NGO for aprotic solvents shows better than polar protic solvents. The surface morphology and element analysis of NGO displayed a leaf like morphology and the elemental compositions of carbon, nitrogen and oxygen in NGO respectively. TNLO property of NGO is investigated by employing z-scan technique in which a continuous wave of wavelength 632.8 nm from He-Ne source was used. This investigation reveals the reverse saturation behaviour and negative nonlinear refractive (NLR) index in NGO. Negative NLR index sign arises mainly from local heating of solvents during continuous interactions of NGO with laser beam. The photoluminescence and TNLO data recorded for NGO revealed its potentiality for bio-sensing, bio-imaging and optoelectronic applications.
Marcano, Aristides; Alvarado, Salvador; Meng, Junwei; Caballero, Daniel; Moares, Ernesto Marín; Edziah, Raymond
2014-01-01
We developed a pump-probe photothermal lens spectrophotometer that uses a broadband arc-lamp and a set of interference filters to provide tunable, nearly monochromatic radiation between 370 and 730 nm as the pump light source. This light is focused onto an absorbing sample, generating a photothermal lens of millimeter dimensions. A highly collimated monochromatic probe light from a low-power He-Ne laser interrogates the generated lens, yielding a photothermal signal proportional to the absorption of light. We measure the absorption spectra of scattering dye solutions using the device. We show that the spectra are not affected by the presence of scattering, confirming that the method only measures the absorption of light that results in generation of heat. By comparing the photothermal spectra with the usual absorption spectra determined using commercial transmission spectrophotometers, we estimate the quantum yield of scattering of the sample. We discuss applications of the device for spectroscopic characterization of samples such as blood and gold nanoparticles that exhibit a complex behavior upon interaction with light.
Kinetic analysis and modeling of daptomycin batch fermentation by Streptomyces roseosporus.
Lu, Wenyu; Fan, Jinghua; Wen, Jianping; Xia, Zhendong; Caiyin, Qinggele
2011-02-01
In this study, Streptomyces roseosporus was subjected to helium-neon (He-Ne) laser (632.8 nm) irradiation to improve the production ability of extracellular antibiotic daptomycin. Under the optimum irradiation dosage of 18 mW for 22 min, a stable positive mutant strain S. roseosporus LC-54 was obtained. The maximum A21978C (daptomycin is a semisynthetic antimicrobial substance derived from the A21978C complex) yield of this mutant strain was 296 mg/l, which was 146% higher than that of the wild strain. The mutant strain grew more quickly and utilized carbohydrate sources more efficiently than the wild strain. The batch culture kinetics was investigated in a 7 l bioreactor. The logistic equation for growth, the Luedeking-Piret equation for daptomycin production, and Luedeking-Piret-like equations for carbon substrate consumption were established. This model appeared to provide a reasonable description for each parameter during the growth phase and fitted fairly well with the experiment data.
Camerlingo, Carlo; Zenone, Flora; Perna, Giuseppe; Capozzi, Vito; Cirillo, Nicola; Gaeta, Giovanni Maria; Lepore, Maria
2008-06-01
A wavelet multi-component decomposition algorithm has been used for data analysis of micro-Raman spectra of blood serum samples from patients affected by pemphigus vulgaris at different stages. Pemphigus is a chronic, autoimmune, blistering disease of the skin and mucous membranes with a potentially fatal outcome. Spectra were measured by means of a Raman confocal microspectrometer apparatus using the 632.8 nm line of a He-Ne laser source. A discrete wavelet transform decomposition method has been applied to the recorded Raman spectra in order to overcome problems related to low-level signals and the presence of noise and background components due to light scattering and fluorescence. This numerical data treatment can automatically extract quantitative information from the Raman spectra and makes more reliable the data comparison. Even if an exhaustive investigation has not been done in this work, the feasibility of the follow-up monitoring of pemphigus vulgaris pathology has been clearly proved with useful implications for the clinical applications.
Camerlingo, Carlo; Zenone, Flora; Perna, Giuseppe; Capozzi, Vito; Cirillo, Nicola; Gaeta, Giovanni Maria; Lepore, Maria
2008-01-01
A wavelet multi-component decomposition algorithm has been used for data analysis of micro-Raman spectra of blood serum samples from patients affected by pemphigus vulgaris at different stages. Pemphigus is a chronic, autoimmune, blistering disease of the skin and mucous membranes with a potentially fatal outcome. Spectra were measured by means of a Raman confocal microspectrometer apparatus using the 632.8 nm line of a He-Ne laser source. A discrete wavelet transform decomposition method has been applied to the recorded Raman spectra in order to overcome problems related to low-level signals and the presence of noise and background components due to light scattering and fluorescence. This numerical data treatment can automatically extract quantitative information from the Raman spectra and makes more reliable the data comparison. Even if an exhaustive investigation has not been done in this work, the feasibility of the follow-up monitoring of pemphigus vulgaris pathology has been clearly proved with useful implications for the clinical applications. PMID:27879899
Mechanism of killing of streptococcus mutans by light-activated drugs
NASA Astrophysics Data System (ADS)
Burns, Tracy; Wilson, Michael; Pearson, G. J.
1996-01-01
Recent studies have shown that cariogenic bacteria can be killed when exposed to low power laser light in the presence of a photosensitizing agent. The purpose of this study was to determine the mechanism by which the cariogenic bacterium Streptococcus mutans can be killed by toluidine blue O and helium neon laser light. To determine whether membrane damage occurred, suspensions of sensitized S. mutans were exposed to a 7.3 mW HeNe laser for 30 mins and samples removed every 5 mins. Survivors were enumerated by viable counting on tryptone soya agar plates and cell free filtrates were assayed for phosphate and (beta) -galactosidase. Lipid peroxidation was assessed by assaying for malondialdehyde, a by- product of lipid peroxidation. The role of oxygen and reactive oxygen species was studied by exposing sensitized bacteria to laser light (1) under different atmospheric conditions, (2) in the presence of deuterium oxide, and (3) in the presence of inhibitors of reactive oxygen species. Following exposure of sensitizede S. mutans to 13.2 J of HeNe laser light, 2.6 nmoles of phosphate and 228 nmoles of (beta) -galactosidase were detected in the cell free filtrates. Ten micrometers oles of malondialdehyde were also detected. When the sensitized bacteria were exposed to laser light under anaerobic conditions there was no significant decrease in the viable count compared to a 60% kill in the presence of oxygen. In the presence of D2O there was a 15-fold increase in the numbers of bacteria killed. O.1 M methionine and 0.5 M sodium azide each afforded 98% protection from lethal photosensitization. These results imply that lethal photosensitization results from membrane damage due to lipid peroxidation and that reactive oxygen species are mediators of this process.
Therapeutic effect of the NMDA antagonist MK-801 on low-level laser induced retinal injury
NASA Astrophysics Data System (ADS)
Yan, W.-H.; Wu, J.; Chen, P.; Dou, J.-T.; Pan, C.-Y.; Mu, Y.-M.; Lu, J.-M.
2009-03-01
The aim of this article was to explore the mechanism of injury in rat retina after constant low-level helium-neon (He-Ne) laser exposure and therapeutic effects of MK-801, an N-methyl-D-aspartate (NMDA) receptor antagonist, on laser-induced retinal injury. He-Ne laser lesions were created in the central retina of adult Wistar Kyoto rats and were followed immediately by intraperitoneal injection of MK-801 (2 mg/kg) or saline, macroscopical and microscopical lesion were observed by funduscope and light microscope. Ultrastructural changes of the degenerating cells were examined by electron microscopy. Photoreceptor apoptosis was evaluated by TdT-mediated dUTP nick end-labeling (TUNEL). mRNA levels were measured by in situ hybridization and NMDA receptor expression was determined by immunohistochemistry. Laser induced damage was histologically quantified by image-analysis morphometry. Electroretinograms (ERGs) were recorded at different time point after the cessation of exposure to constant irradiation. There was no visible bleeding, exudation or necrosis under funduscope. TUNEL and electron microscopy showed photoreceptor apoptosis after irradiation. MK-801-treated animals had significantly fewer TUNEL-positive cells in the photoreceptors than saline-treated animals after exposure to laser. In situ hybridization (ISH) showed that the NMDAR mRNA level of MK-801-treated rats decreased in the inner plexiform layer 6 h after the cessation of exposure to constant irradiation when compared with that of saline-treated rats. So did Immunohistochemistry (IHC). Electroretinogram showed that b-wave amplitudes of MK-801-treated group were higher than that of saline-treated group after laser exposure. These findings suggest that Low level laser may cause the retinal pathological changes under given conditions. High expression of NMDAR is one of the possible mechanisms causing experimental retinal laser injury of rats. MK-801 exhibits the therapeutic effect due to promote the recovery of structure and function of injured retina.
Suhem, Kitiya; Matan, Narumol; Matan, Nirundorn; Danworaphong, Sorasak; Aewsiri, Tanong
2015-12-23
The aim of this study was to improve the antifungal activity of the volatile Litsea cubeba essential oil and its main components (citral and limonene) on brown rice snack bars by applying He-Ne laser treatment. Different volumes (50-200 μL) of L. cubeba, citral or limonene were absorbed into a filter paper and placed inside an oven (18 L). Ten brown rice snack bars (2 cm wide × 4 cm long × 0.5 cm deep) were put in an oven and heated at 180 °C for 20 min. The shelf-life of the treated snack bars at 30 °C was assessed and sensory testing was carried out to investigate their consumer acceptability. A count of total phenolic content (TPC) and Fourier transform infrared spectroscopy (FTIR) on the properties of essential oil, citral, and limonene before and after the laser treatment was studied for possible modes of action. It was found that the laser treatment improved the antifungal activity of the examined volatile L. cubeba and citral with Aspergillus flavus inhibition by 80% in comparison with those of the control not treated with the laser. L. cubeba vapor at 100 μL with the laser treatment was found to completely inhibit the growth of natural molds on the snack bars for at least 25 days; however, without essential oil vapor and laser treatment, naturally contaminating mold was observed in 3 days. Results from the sensory tests showed that the panelists were unable to detect flavor and aroma differences between essential oil treatment and the control. Laser treatment caused an increase in TPC of citral oil whereas the TPC in limonene showed a decrease after the laser treatment. These situations could result from the changing peak of the aliphatic hydrocarbons that was revealed by the FTIR spectra. Copyright © 2015 Elsevier B.V. All rights reserved.
Ocular dynamics and visual tracking performance after Q-switched laser exposure
NASA Astrophysics Data System (ADS)
Zwick, Harry; Stuck, Bruce E.; Lund, David J.; Nawim, Maqsood
2001-05-01
In previous investigations of q-switched laser retinal exposure in awake task oriented non-human primates (NHPs), the threshold for retinal damage occurred well below that of the threshold for permanent visual function loss. Visual function measures used in these studies involved measures of visual acuity and contrast sensitivity. In the present study, we examine the same relationship for q-switched laser exposure using a visual performance task, where task dependency involves more parafoveal than foveal retina. NHPs were trained on a visual pursuit motor tracking performance task that required maintaining a small HeNe laser spot (0.3 degrees) centered in a slowly moving (0.5deg/sec) annulus. When NHPs reliably produced visual target tracking efficiencies > 80%, single q-switched laser exposures (7 nsec) were made coaxially with the line of sight of the moving target. An infrared camera imaged the pupil during exposure to obtain the pupillary response to the laser flash. Retinal images were obtained with a scanning laser ophthalmoscope 3 days post exposure under ketamine and nembutol anesthesia. Q-switched visible laser exposures at twice the damage threshold produced small (about 50mm) retinal lesions temporal to the fovea; deficits in NHP visual pursuit tracking were transient, demonstrating full recovery to baseline within a single tracking session. Post exposure analysis of the pupillary response demonstrated that the exposure flash entered the pupil, followed by 90 msec refractory period and than a 12 % pupillary contraction within 1.5 sec from the onset of laser exposure. At 6 times the morphological threshold damage level for 532 nm q-switched exposure, longer term losses in NHP pursuit tracking performance were observed. In summary, q-switched laser exposure appears to have a higher threshold for permanent visual performance loss than the corresponding threshold to produce retinal threshold injury. Mechanisms of neural plasticity within the retina and at higher visual brain centers may mediat
OCT imaging with temporal dispersion induced intense and short coherence laser source
NASA Astrophysics Data System (ADS)
Manna, Suman K.; le Gall, Stephen; Li, Guoqiang
2016-10-01
Lower coherence length and higher intensity are two indispensable requirements on the light source for high resolution and large penetration depth OCT imaging. While tremendous interest is being paid on engineering various laser sources to enlarge their bandwidth and hence lowering the coherence length, here we demonstrate another approach by employing strong temporal dispersion onto the existing laser source. Cholesteric liquid crystal (CLC) cells with suitable dispersive slope at the edge of 1-D organic photonic band gap have been designed to provide maximum reduction in coherence volume while maintaining the intensity higher than 50%. As an example, the coherence length of a multimode He-Ne laser is reduced by more than 730 times.
Surface Plasmons in Silver Films--A Novel Undergraduate Experiment
ERIC Educational Resources Information Center
Simon, H. J.; And Others
1975-01-01
Describes an experiment in which a 500-A-thick silver film is evaporated on the hypotenuse face of a right glass prism. The surface plasmon mode in the film is excited with a He-Ne laser. The dispersion relation for the surface plasmon and the reflectivity due to the excitation of this mode are calculated. (Author/MLH)
NASA Astrophysics Data System (ADS)
Darwiesh, M.; El-Sherif, Ashraf F.; El-Ghandour, Hatem; Aly, Hussein A.; Mokhtar, A. M.
2011-03-01
Optical imaging systems are widely used in different applications include tracking for portable scanners; input pointing devices for laptop computers, cell phones, and cameras, fingerprint-identification scanners, optical navigation for target tracking, and in optical computer mouse. We presented an experimental work to measure and analyze the laser speckle pattern (LSP) produced from different optical sources (i.e. various color LEDs, 3 mW diode laser, and 10mW He-Ne laser) with different produced operating surfaces (Gabor hologram diffusers), and how they affects the performance of the optical imaging systems; speckle size and signal-to-noise ratio (signal is represented by the patches of the speckles that contain or carry information, and noise is represented by the whole remaining part of the selected image). The theoretical and experimental studies of the colorimetry (color correction is done in the color images captured by the optical imaging system to produce realistic color images which contains most of the information in the image by selecting suitable gray scale which contains most of the informative data in the image, this is done by calculating the accurate Red-Green-Blue (RGB) color components making use of the measured spectrum for light sources, and color matching functions of International Telecommunication Organization (ITU-R709) for CRT phosphorus, Tirinton-SONY Model ) for the used optical sources are investigated and introduced to present the relations between the signal-to-noise ratios with different diffusers for each light source. The source surface coupling has been discussed and concludes that the performance of the optical imaging system for certain source varies from worst to best based on the operating surface. The sensor /surface coupling has been studied and discussed for the case of He-Ne laser and concludes the speckle size is ranged from 4.59 to 4.62 μm, which are slightly different or approximately the same for all produced diffusers (which satisfies the fact that the speckle size is independent on the illuminating surface). But, the calculated value of signal-tonoise ratio takes different values ranged from 0.71 to 0.92 for different diffuser. This means that the surface texture affects the performance of the optical sensor because, all images captured for all diffusers under the same conditions [same source (He-Ne laser), same distances of the experimental set-up, and the same sensor (CCD camera)].
Dadhich, Bhavesh Kumar; Kumar, Indrajit; Choubey, Ravi Kant; Bhushan, Bhavya; Priyam, Amiya
2017-10-11
Using a combination of a mild stabilizer and a mild reductant, sodium citrate and hydrazine hydrate, anisotropic silver nanocrystals (NCs) were synthesized with tunable plasmon peaks at 550 nm, 700 nm, 800 nm, 900 nm and 1010 nm (the samples are named Ag-550, Ag-700, Ag-800, Ag-900 and Ag-1010, respectively). TEM investigations revealed that Ag-550 NCs were pentagonal nanoplates while the other four samples were nanopyramids with a pentagonal base with the edge length varying between 15 and 30 nm. The non-linear optical (NLO) properties of these NCs were studied by the Z-scan technique using the CW He-Ne laser (632.8 nm, 15 mW). The shape change from 2D nanoplates (Ag-550) to 3D nanopyramids (Ag-700) resulted in sign reversal of the non-linear refractive index, n 2 , from a negative (-3.164 × 10 -8 cm 2 W -1 ) to a positive one (1.195 × 10 -8 cm 2 W -1 ). This corresponds to a change from a self-defocussing effect to a self-focussing one. Besides shape, the size effect is also prominently observed. Amongst nanopyramids, as the edge length increases, n 2 increases linearly and reaches a maximum of 3.124 × 10 -8 cm 2 W -1 . Doubling the edge length from 15 nm to 30 nm resulted in 162% increase in n 2 . On moving from Ag-550 to Ag-900 NCs, with the increasing plasmon wavelength, the non-linear absorption (NLA) coefficient increased exponentially to a high value of 8.52 × 10 -4 cm W -1 . However, Ag-1010 showed 29% decrease in NLA which is attributed to twinning present in the crystal structure as seen in the HR-TEM images. Due to the tunable NLO properties, these anisotropic Ag NCs hold great potential for applications in optical limiting, switching and data storage.
Infrared characteristics of VO2 thin films for smart window and laser protection applications
NASA Astrophysics Data System (ADS)
Huang, Zhangli; Chen, Sihai; Lv, Chaohong; Huang, Ying; Lai, Jianjun
2012-11-01
Vanadium dioxide (VO2) films with a low semiconductor-to-metal transition temperature of 45 °C were fabricated through direct current magnetron sputtering followed by a post-annealing. Atomic force microscopy measurements show that the VO2 grain size is about one hundred of nanometers. Infrared (IR) characteristic is well investigated by applying a He-Ne laser power intensity measurement, and the result reveals that the VO2 film exhibits excellent IR switching property. Furthermore, solar smart window and laser protection experiments demonstrate that the obtained VO2 thin film is a promising material for the application in related fields.
Antares Alignment Gimbal Positioner
NASA Astrophysics Data System (ADS)
Day, R. D.; Viswanathan, V. K.; Saxman, A. C.; Lujan, R. E.; Woodfin, G. L.; Sweatt, W. C.
1981-12-01
Antares is a 24-beam 40-TW carbon-dioxide (CO2) laser fusion system currently under construction at the Los Alamos National Laboratory. The Antares alignment gimbal positioner (AGP) is an optomechanical instrument that will be used for target alignment and alignment of the 24 laser beams, as well as beam quality assessments. The AGP will be capable of providing pointing, focusing, and wavefront optical path difference, as well as aberration information at both helium-neon (He-Ne) and CO2 wavelengths. It is designed to allow the laser beams to be aligned to any position within a 1-cm cube to a tolerance of 10 μm.
Designing and testing a laser-based vibratory sensor
NASA Astrophysics Data System (ADS)
Nath, G.
2018-04-01
Sensor technology has proved its importance, not only in the range of few-meter applications in different fields, but in micro, nano, atomic and sub-atomic-sized objects. The present work describes the designing of a laser-based vibratory sensor using a He-Ne laser as the signal source. The received characteristics of the signal are mainly the frequency and amplitude of the vibration from which the physical parameters such as energy, power and absorption coefficients of the material are determined, which enables us to provide information of the hidden target or object. This laboratory-designed sensor finds application in different local phenomena as well as laboratory practical activity for students.
NASA Technical Reports Server (NTRS)
Muckerheide, M. C.
1987-01-01
The high peak power neodymium YAG laser and the HeNe laser aboard GAS-449 have demonstrated the survivability of the devices in the micro-gravity, cosmic radiation, thermal, and shock environment of space. Some pharmaceuticals and other materials flown in both the active and passive status have demonstrated reduction in volume and unusual spectroscopic changes. X-ray detectors have shown cosmic particle hits with accompanying destruction at their interaction points. Some scattering in the plates is in evidence. Some results of both active and passive experiments on board the GAS-449 payload are evaluated.
Equipment and Tracking Test Results for the NRL Ship-to- Ship DF Laser Transmission Experiment.
1982-04-05
combined with the 2" collimated HeNe laser beam at dichoric beam splitter TBSI. TF2, TF1 , and TPFI direct the beam onto the f/6 parabola Pl. From...following work was done on the pumping system: 1. Install new valves , springs, and seats. 2. Install a new drive shaft, with new bearings and seals. 3...Install a new needle valve in the oil regulator. 4. Steam clean the inside pump surface. The new components were tested first with F2 fuel, then with NF 3
NASA Astrophysics Data System (ADS)
Alodzhants, A. P.; Dzheĭranyan, G. A.; Gevorkyan, L. P.; Arakelyan, S. M.
1993-08-01
The creation of nonclassical states of light in tunnel-coupled optical fibers is analyzed. It is possible to achieve a 40% suppression of quantum (vacuum) fluctuations in one quadrature of the field of a standard cw He-Ne laser with an intensity as low as 1 kW/cm2 (i.e., a power of ~ 1 mW). The possibility of experimental implementation of this scheme for generating squeezed quantum states is discussed.
Refraction of light on enamel surface
NASA Astrophysics Data System (ADS)
Grisimov, Vladimir N.
1997-12-01
The direction of He-Ne laser beam propagation in enamel is studied while the laser radiation was aimed on to enamel surface of flat longitudinal and transversal teeth slices. The slices with hypermineralized and transparent enamel (so called opalescent enamel) have been examined. The patterns of side-scattering of light have been detected by CCD camera. The scattering (Tyndall effect) and refraction of radiation have been observed. The data obtained explain some features of teeth exterior under increasing of enamel transparency and may be used for right choice of necessary hue of composite during tooth esthetic restoration.
Electric current heating calibration of a laser holographic nondestructive test system
NASA Technical Reports Server (NTRS)
Liu, H.-K.; Kurtz, R. L.
1975-01-01
Holographic NDT was used to measure small surface displacements controlled by electric heating by detecting the difference of the interference fringe patterns as viewed through the hologram on a real time basis. A perforated aluminum test plate, with the holes used to position thin metal foils, was used in the experiment. One of the foils was connected to an electric power source and small displacements of the foil were caused and controlled by Ohmic heating. An He-Ne laser was used to perform the holography.
NASA Astrophysics Data System (ADS)
Biswas, S.; Kumbhakar, P.
2017-02-01
We have reported here, for the first time, to the best of our knowledge, a high nonlinear refractive index (n2e) of a natural pigment extracted from Hibiscus rosa-sinensis leaves by using spatial self-phase modulation technique (SSPM) with a low power CW He-Ne laser radiation at 632.8 nm. It is found by UV-Vis absorption spectroscopic analysis that chlrophyll-a, chlrophyll-b and carotenoid are present in the pigment extract with 56%, 25% and 19%, respectively. The photoluminescence (PL) emission characteristics of the extracted samples have also been measured at room temperature as well as in the temperature range of 283-333 K to investigate the effect of temperature on luminescent properties of the sample. By analyzing the SSPM experimental data, the nonlinear refractive index value of pigment extract has been determined to be 3.5 × 10- 5 cm2/W. The large nonlinear refractive index has been assigned due to asymmetrical structure, molecular reorientation and thermally induced nonlinearity in the sample. The presented results might open new avenues for the green and economical technique of syntheses of organic dyes with such a large nonlinear optical property.
Suwada, Tsuyoshi; Satoh, Masanori; Telada, Souichi; Minoshima, Kaoru
2013-09-01
A laser-based alignment system with a He-Ne laser has been newly developed in order to precisely align accelerator units at the KEKB injector linac. The laser beam was first implemented as a 500-m-long fiducial straight line for alignment measurements. We experimentally investigated the propagation and stability characteristics of the laser beam passing through laser pipes in vacuum. The pointing stability at the last fiducial point was successfully obtained with the transverse displacements of ±40 μm level in one standard deviation by applying a feedback control. This pointing stability corresponds to an angle of ±0.08 μrad. This report contains a detailed description of the experimental investigation for the propagation and stability characteristics of the laser beam in the laser-based alignment system for long-distance linear accelerators.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Suwada, Tsuyoshi; Satoh, Masanori; Telada, Souichi
2013-09-15
A laser-based alignment system with a He-Ne laser has been newly developed in order to precisely align accelerator units at the KEKB injector linac. The laser beam was first implemented as a 500-m-long fiducial straight line for alignment measurements. We experimentally investigated the propagation and stability characteristics of the laser beam passing through laser pipes in vacuum. The pointing stability at the last fiducial point was successfully obtained with the transverse displacements of ±40 μm level in one standard deviation by applying a feedback control. This pointing stability corresponds to an angle of ±0.08 μrad. This report contains a detailedmore » description of the experimental investigation for the propagation and stability characteristics of the laser beam in the laser-based alignment system for long-distance linear accelerators.« less
Correlation between He-Ne scatter and 2.7-microm pulsed laser damage at coating defects.
Porteus, J O; Spiker, C J; Franck, J B
1986-11-01
A reported correlation between defect-initiated pulsed laser damage and local predamage scatter in multilayer infrared mirror coatings has been analyzed in detail. Examination of a much larger data base confirms the previous result on dielectric-enhanced reflectors with polished substrates over a wide range of energy densities above the damage onset. Scatter signals from individual undamaged defects were detected using a He-Ne scatter probe with a focal spot that nearly coincides with the 150-microm-diam (D1/e(2)) focal spot of the damage-probe beam. Subsequent damage frequency measurements (1-on-1) were made near normal or at 45 degrees incidence with 100-ns pulses at 2.7-microm wavelength. The correlation is characterized by an increase in damage frequency with increasing predamage scatter signal and by equivalence of the defect densities indicated by the two probes. Characteristics of the correlation are compared with a simple model based on focal spot intensity profiles. Conditions that limit correlation are discussed, including variable scatter from defects and background scatter from diamond-turned substrates. Results have implication for nondestructive defect detection and coating quality control.
NASA Technical Reports Server (NTRS)
Hoge, F. E.; Kincaid, J. S.
1980-01-01
A coaxial dual-channel laser system has been developed for the measurement of extinction coefficients of highly absorbing liquids. An empty wedge-shaped sample cell is first translated laterally through a He-Ne laser beam to measure the differential thickness using interference fringes in reflection. The wedge cell is carefully filled with the oil sample and translated through the coaxially positioned dye laser beam for the differential attenuation or extinction measurement. Optional use of the instrumentation as a single-channel extinction measurement system and also as a refractometer is detailed. The system and calibration techniques were applied to the measurement of two crude oils whose extinction values were required to complete the analysis of airborne laser data gathered over four controlled spills.
Kim, Dong Ik; Rhee, Hyug-Gyo; Song, Jae-Bong; Lee, Yun-Woo
2007-10-01
We present experimental results on the output power stabilization of an Ar(+) laser for a direct laser writing system (LWS). Instability of the laser output power in the LWS cause resolution fluctuations of being fabricated diffractive optical elements or computer-generated holograms. For the purpose of reducing the power fluctuations, we have constituted a feedback loop with an acousto-optic modulator, a photodetector, and a servo controller. In this system, we have achieved the stability of +/-0.20% for 12 min and the relative intensity noise level of 2.1 x 10(-7) Hz(-12) at 100 Hz. In addition, we applied our system to a 2 mW internal mirror He-Ne laser. As a consequence, we achieved the output power stability of +/-0.12% for 25 min.
Development of laser transmission system
NASA Astrophysics Data System (ADS)
Song, Jiawu; Zhang, Yulan; Yang, Jiandong; Zhang, Xinming
1998-08-01
This paper discusses a light transfer system of therapeutic machine using carbon-dioxide laser. This system is based on imitating human being arm motion principle, consists of optical cardans mainly and can move in three-D space freely. Through it carbon-dioxide laser (which wavelength is 10.6 micrometer) is reflected, focused or diverged and transferred to the different therapeutic part of body to realize the purpose of cutting operation, gasification, cauterization and irradiation. This system includes an indicating system using He-Ne laser, by which carbon-dioxide laser can arrive therapeutic part accurately. This system possesses some advantages e.g. an accurate transfer, large moving range, small power consumption, high power density and easy operation. At present the occupancy in home market of this kind laser transfer system products is over 95%. Some products have been exported to other countries.
Analysis of higher order harmonics with holographic reflection gratings
NASA Astrophysics Data System (ADS)
Mas-Abellan, P.; Madrigal, R.; Fimia, A.
2017-05-01
Silver halide emulsions have been considered one of the most energetic sensitive materials for holographic applications. Nonlinear recording effects on holographic reflection gratings recorded on silver halide emulsions have been studied by different authors obtaining excellent experimental results. In this communication specifically we focused our investigation on the effects of refractive index modulation, trying to get high levels of overmodulation that will produce high order harmonics. We studied the influence of the overmodulation and its effects on the transmission spectra for a wide exposure range by use of 9 μm thickness films of ultrafine grain emulsion BB640, exposed to single collimated beams using a red He-Ne laser (wavelength 632.8 nm) with Denisyuk configuration obtaining a spatial frequency of 4990 l/mm recorded on the emulsion. The experimental results show that high overmodulation levels of refractive index produce second order harmonics with high diffraction efficiency (higher than 75%) and a narrow grating bandwidth (12.5 nm). Results also show that overmodulation produce diffraction spectra deformation of the second order harmonic, transforming the spectrum from sinusoidal to approximation of square shape due to very high overmodulation. Increasing the levels of overmodulation of refractive index, we have obtained higher order harmonics, obtaining third order harmonic with diffraction efficiency (up to 23%) and narrowing grating bandwidth (5 nm). This study is the first step to develop a new easy technique to obtain narrow spectral filters based on the use of high index modulation reflection gratings.
NASA Astrophysics Data System (ADS)
Sunatkari, A. L.; Talwatkar, S. S.; Tamgadge, Y. S.; Muley, G. G.
2018-05-01
Highly stable colloidal gold nanoparticles (GNPs) stabilised in l-arginine were synthesized and embedded in polyvinyl pyrrolidone (PVP) polymer matrix to fabricate thin films by spin coating method. Nonlinear optical response of GNP-PVP nanocomposite were investigated using single beam Z-scan technique using He-Ne laser beam in CW regime operated at 632.8 nm as an excitation source. The sign of nonlinear refractive index was found negative, which is of self-defocusing nature. The nonlinear optical parameters estimated for GNP-PVP nanocomposite and found values as large as n2≈(1.7 -3.1 ) ×10-4c m2W-1, β ≈(2.40 -4.69 ) ×10-5c m W-1 and χef f (3 )≈(2.30 -4.34 ) ×10-4e s u . The nonlinear refractive index, absorption coefficient and third order nonlinear susceptibility have found decreasing with the increase in the concentration of l-arginine. Localized surface plasmon resonance (LSPR) peaks show the blue shift. The average size of the GNPs is found reducing from 11 nm to 7.5 nm with the increase in the stabilizer concentration, as analysed by transmission electron microscopy. The XRD study reveals face-centred cubic (fcc) structure of GNPs. The huge nonlinearity is attributed to the thermo-optic phenomenon. The huge enhancement in third order nonlinear susceptibility and nonlinear refractive index indicates that this optical material possess a high potential for various optoelectronic devices applications.
Design and study of deep laser acupuncture stimulator of modulation and multibeam
NASA Astrophysics Data System (ADS)
Mao, Haitao; Wang, Qingguo; Xing, Qian; Li, Fangzheng; Cheng, Dongan
2002-04-01
The laser acupuncture stimulation has been applied extensively to replace the acupuncture needles. But the laser is transmitted to the acupoint through the skin, so the curative effect of the laser irradiation on an acupoint from cuticle is limited. We have developed the deep laser acupuncture stimulator of modulation and multibeam. The laser beam (such as He-Ne, LD, etc.) is turned into the modulated waveform. The modulated laser beam can simulate the customary acupuncture way such as twirling and rotating, etc. The laser beam is split into 3-8 beams by the means of optical shunt. After that they enter into laser acupuncture pins separately through the optical fiber joiners. The laser beam and pins can give simultaneously the stimulation in the depths of 3-8 acupoints. It has been proved by the clinical practice that the deep laser acupuncture has the notable efficiency for the apoplexy and sequelae of apoplexy, sciatica, rheumatoid arthritis, etc.
Antares alignment gimbal positioner
DOE Office of Scientific and Technical Information (OSTI.GOV)
Day, R.D.; Viswanathan, V.K.; Saxman, A.C.
1981-01-01
Antares is a 24-beam 40-TW carbon-dioxide (CO/sub 2/) laser fusion system currently under construction at the Los Alamos National Laboratory. The Antares alignment gimbal positioner (AGP) is an optomechanical instrument that will be used for target alignment and alignment of the 24 laser beams, as well as beam quality assessments. The AGP will be capable of providing pointing, focusing, and wavefront optical path difference, as well as aberration information at both helium-neon (He-Ne) and CO/sub 2/ wavelengths. It is designed to allow the laser beams to be aligned to any position within a 1-cm cube to a tolerance of 10more » ..mu..m.« less
NASA Astrophysics Data System (ADS)
Xu, Lin; Zhang, Canbang; Wen, Yuanbin; Liu, Shuxiao; Zhou, Lingyun
2009-08-01
Some cases with cerebral infarction were treated by He-Ne laser irradiation on blood. In the treatment before and after, membrane-cholesterol(C)/membrane-phosphatide(P), membrane fluidity(F) and deformability of erythrocyte were determined. The results showed that low level laser irradiation on blood (LLLIB) can sure reduce the ratio of (C)/(P), can heighten fluidity and improve deformability of erythrocyte .Thus the metabolism ability of erythrocyte membrane-lipid ,the blood circulation and the properties of hemorheology can be improved. In this paper, the microscopic mechanism of those aforesaid action effects by low level laser irradiation on blood were analyzed by means of Quantum theory and some corresponding models.
Monitoring the Thermal Parameters of Different Edible Oils by Using Thermal Lens Spectrometry
NASA Astrophysics Data System (ADS)
Jiménez-Pérez, J. L.; Cruz-Orea, A.; Lomelí Mejia, P.; Gutierrez-Fuentes, R.
2009-08-01
Several vegetable edible oils (sunflower, canola, soya, and corn) were used to study the thermal diffusivity of edible oils. Thermal lens spectrometry (TLS) was applied to measure the thermal properties. The results showed that the obtained thermal diffusivities with this technique have good agreement when compared with literature values. In this technique an Ar+ laser and intensity stabilized He-Ne laser were used as the heating source and probe beam, respectively. These studies may contribute to a better understanding of the physical properties of edible oils and the quality of these important foodstuffs.
Millimeter-wave generation and characterization of a GaAs FET by optical mixing
NASA Technical Reports Server (NTRS)
Ni, David C.; Fetterman, Harold R.; Chew, Wilbert
1990-01-01
Coherent mixing of optical radiation from a tunable continuous-wave dye laser and a stabilized He-Ne laser was used to generate millimeter-wave signals in GaAs FETs attached to printed-circuit millimeter-wave antennas. The generated signal was further down-converted to a 2-GHz IF by an antenna-coupled millimeter-wave local oscillator at 62 GHz. Detailed characterizations of power and S/N under different bias conditions have been performed. This technique is expected to allow signal generation and frequency-response evaluation of millimeter-wave devices at frequencies as high as 100 GHz.
NASA Technical Reports Server (NTRS)
Su, C.- H.; Feth, S.; Lehoczky, S. L.
1998-01-01
ZnSe crystals grown in sealed ampoules by the physical vapor transport method were monitored in situ using three techniques, simultaneously. A Michelson interferometer was set-up to observe the growth rate and surface morphological evolution. An interference pattern (interferogram) is formed by the interaction between the reflection of a HeNe laser (632.8 nm wavelength) off the crystal-vapor interface and a reference beam from the same laser. Preliminary results indicate that the rate of growth/thermal-etching can be calculated using analog data acquisition and simple fringe counting techniques. Gross surface features may also be observed using a digital frame grabber and fringe analysis software. The second in situ technique uses optical absorption to determine the partial pressures of the vapor species. The Se2 and Zn vapor species present in the sealed ampoule absorb light at characteristic wavelengths. The optical absorption is determined by monitoring the light intensity difference between the sample and reference beams. The Se2 Partial pressure profile along the length of the ampoule was estimated from the vibronic absorption peaks at 340.5, 350.8, 361.3 and 379.2 nm using the Beer's law constants established in the calibration runs of pure Se. Finally, because the high temperature crystal growth furnace contains windows, in situ visual observation of the growing crystal is also possible. The use of these techniques not only permits in situ investigation of high temperature vapor growth of semiconductors, but also offers the potential for real time feed back on the growing crystal and allows the possibility of actively controlling the growth process.
NASA Technical Reports Server (NTRS)
Zuev, V. E.; Andreev, Y. M.; Voevodin, V. G.; Gribenyukov, A. I.; Kapitanov, V. A.; Sosnin, A. V.; Stuchebrov, G. A.; Khmelnitskii, G. S.
1986-01-01
The results of field measurements of concentration of some gaseous components of the atmosphere along the paths, in Sofia, Bulgaria, using a gas analyzer based on the use of a CO2 laser radiation frequency-doubled with ZnGeP2 monocrystals are presented. The gas analyzer is a traditional long path absorption meter. Radiation from the tunable CO2 laser of low pressure and from an additional He-Ne laser is directed to a colliminating hundredfold Gregori telescope with a 300 mm diameter of the principal mirror. The dimensions of the mirrors of a retroreflector 500 x 500 mm and a receiving telescope allow one to totally intercept the beam passed through the atmospheric layer under study and back.
Precision Electron Density Measurements in the SSX MHD Wind Tunnel
NASA Astrophysics Data System (ADS)
Suen-Lewis, Emma M.; Barbano, Luke J.; Shrock, Jaron E.; Kaur, Manjit; Schaffner, David A.; Brown, Michael R.
2017-10-01
We characterize fluctuations of the line averaged electron density of Taylor states produced by the magnetized coaxial plasma gun of the SSX device using a 632.8 nm HeNe laser interferometer. The analysis method uses the electron density dependence of the refractive index of the plasma to determine the electron density of the Taylor states. Typical magnetic field and density values in the SSX device approach about B ≅ 0.3 T and n = 0 . 4 ×1016 cm-3 . Analysis is improved from previous density measurement methods by developing a post-processing method to remove relative phase error between interferometer outputs and to account for approximately linear phase drift due to low-frequency mechanical vibrations of the interferometer. Precision density measurements coupled with local measurements of the magnetic field will allow us to characterize the wave composition of SSX plasma via density vs. magnetic field correlation analysis, and compare the wave composition of SSX plasma with that of the solar wind. Preliminary results indicate that density and magnetic field appear negatively correlated. Work supported by DOE ARPA-E ALPHA program.
The application of Fresnel zone plate based projection in optofluidic microscopy.
Wu, Jigang; Cui, Xiquan; Lee, Lap Man; Yang, Changhuei
2008-09-29
Optofluidic microscopy (OFM) is a novel technique for low-cost, high-resolution on-chip microscopy imaging. In this paper we report the use of the Fresnel zone plate (FZP) based projection in OFM as a cost-effective and compact means for projecting the transmission through an OFM's aperture array onto a sensor grid. We demonstrate this approach by employing a FZP (diameter = 255 microm, focal length = 800 microm) that has been patterned onto a glass slide to project the transmission from an array of apertures (diameter = 1 microm, separation = 10 microm) onto a CMOS sensor. We are able to resolve the contributions from 44 apertures on the sensor under the illumination from a HeNe laser (wavelength = 633 nm). The imaging quality of the FZP determines the effective field-of-view (related to the number of resolvable transmissions from apertures) but not the image resolution of such an OFM system--a key distinction from conventional microscope systems. We demonstrate the capability of the integrated system by flowing the protist Euglena gracilis across the aperture array microfluidically and performing OFM imaging of the samples.
Wavelet data analysis of micro-Raman spectra for follow-up monitoring in oral pathologies
NASA Astrophysics Data System (ADS)
Camerlingo, C.; Zenone, F.; Perna, G.; Capozzi, V.; Cirillo, N.; Gaeta, G. M.; Lepore, M.
2008-02-01
A wavelet multi-component decomposition algorithm has been used for data analysis of micro-Raman spectra from human biological samples. In particular, measurements have been performed on some samples of oral tissue and blood serum from patients affected by pemphigus vulgaris at different stages. Pemphigus is a chronic, autoimmune, blistering disease of the skin and mucous membranes with a potentially fatal outcome. The disease is characterized histologically by intradermal blisters and immunopathologically by the finding of tissue bound and circulating immunoglobulin G (IgG) antibody directed against the cell surface of keratinocytes. More than 150 spectra were measured by means of a Raman confocal microspectrometer apparatus using the 632.8 nm line of a He-Ne laser source. A discrete wavelet transform decomposition method has been applied to the recorded Raman spectra in order to overcome related to low-level signals and the presence of noise and background components due to light scattering and fluorescence. The results indicate that appropriate data processing can contribute to enlarge the medical applications of micro-Raman spectroscopy.
Clinical results from low-level laser therapy in patients with autosomal dominant cone-rod dystrophy
NASA Astrophysics Data System (ADS)
Koev, K.; Avramov, L.; Borissova, E.
2018-03-01
The objective of this study is to examine long-term effects of low-level laser therapy (LLLT) in patients with autosomal dominant cone-rod dystrophy (CRDs). A He-Ne Laser with continuous emission at 633 nm (01 mW/cm2) was used on five patients with autosomal dominant pedigree of Romani origin with non-syndromic CRDs. The laser radiation was applied transpupillary to the macula six times for three minutes every other day. The experiment was conducted for a period of three years. The clinical evaluation included best corrected visual acuity determination, funduscopy, Humphrey perimetry, Farnsworth Hue-28 color testing, fluorescein angiography, and full-field electroretinogram (ERG). All affected individuals presented reduced visual acuity (0.01 – 0.4) and photophobia. The funduscopic examination and fluorescein angiography revealed advanced changes including bone spicule-like pigment deposits in the midperiphery and the macular area, along with retinal atrophy, narrowing of the vessels, and waxy optic discs. The visual fields demonstrated central scotoma. The electrophysiologic examination of the patients detected an abnormal cone-rod ERG (20 – 30 μV) with photopic amplitudes more markedly reduced than the scotopic. Flicker responses were missing and Farnsworth Hue-28 test found protanopia. There was a statistically significant increase in the visual acuity (p<0.001, end of study versus baseline) for CRDs patients for the period of three years after the treatment with LLLT. Following the LLLT, the central absolute scotoma in CRDs was reduced, as was the prevalence of metamorphopsia in CRDs. This study shows that LLLT may prove be a novel long-lasting therapeutic option for both forms of CRDs. It is a highly effective treatment resulting in a long-term improvement of the visual acuity.
An investigation and conceptual design of a holographic starfield and landmark tracker
NASA Technical Reports Server (NTRS)
Welch, J. D.
1973-01-01
The analysis, experiments, and design effort of this study have supported the feasibility of the basic holographic tracker concept. Image intensifiers and photoplastic recording materials were examined, along with a Polaroid rapid process silver halide material. Two reference beam, coherent optical matched filter technique was used for multiplexing spatial frequency filters for starfields. A 1 watt HeNe laser and an electro-optical readout are also considered.
Comparative Characteristics Of Coherent And Incoherent Radiation In The Photography Of Ulcer
NASA Astrophysics Data System (ADS)
Novikov, V. F.; Paramonov, L. V.
1985-01-01
The efficiency of He-Ne laser radiation and incoherent radiation by red light sources with different spectral bandwidths is compared for the endoscopic phototherapy of gastric and duodenal ulcers. Coherent and incoherent radiation is determined to result in the same theraputic effect when doing the treatment of ulcer deseases. The methods of ulcer treatment is suggested with a conventional fibrogastroscope fitted with red glass filter.
Programmable CGH on photochromic material using DMD generated masks
NASA Astrophysics Data System (ADS)
Alata, Romain; Zamkotsian, Frédéric; Lanzoni, Patrick; Pariani, Giorgio; Bianco, Andrea; Bertarelli, Chiara
2018-02-01
Computer Generated Holograms (CGHs) are used for wavefront shaping and complex optics testing, including aspherical and free-form optics. Today, CGHs are recorded directly with a laser or intermediate masks, allowing only the realization of binary CGHs; they are efficient but can reconstruct only pixilated images. We propose a Digital Micromirror Device (DMD) as a reconfigurable mask, to record rewritable binary and grayscale CGHs on a photochromic plate. The DMD is composed of 2048x1080 individually controllable micro-mirrors, with a pitch of 13.68 μm. This is a real-time reconfigurable mask, perfect for recording CGHs. The photochromic plate is opaque at rest and becomes transparent when it is illuminated with visible light of suitable wavelength. We have successfully recorded the very first amplitude grayscale CGH, in equally spaced levels, so called stepped CGH. We recorded up to 1000x1000 pixels CGHs with a contrast greater than 50, using Fresnel as well as Fourier coding scheme. Fresnel's CGH are obtained by calculating the inverse Fresnel transform of the original image at a given focus, ranging from 50cm to 2m. The reconstruction of the recorded images with a 632.8nm He-Ne laser beam leads to images with a high fidelity in shape, intensity, size and location. These results reveal the high potential of this method for generating programmable/rewritable grayscale CGHs, which combine DMDs and photochromic substrates.
FIBER AND INTEGRATED OPTICS: Multiplexed optical-fiber sensors with autodyne detection
NASA Astrophysics Data System (ADS)
Potapov, V. T.; Mamedov, A. M.; Shatalin, S. V.; Yushkaĭtis, R. V.
1993-09-01
A method is proposed for multiplexing optical-fiber interference sensors. The method involves autodyne reception of frequency-modulated radiation reflected back to the laser. The response of a He-Ne laser with a linearly varying generation frequency to radiation reflected back from a single-mode fiber is studied. The spectrum of beats caused in the laser radiation by the reflection is shown to be governed by the distribution of reflectors along the fiber. The phases of the spectral components contain information about the phase shift of the reflected optical signal. A hydrophone array with a sensitivity of 30 μrad/Hz1/2 is described. A distributed temperature sensor with a spatial resolution of 1 m is also described.
NASA Astrophysics Data System (ADS)
Pikálek, Tomáš; Šarbort, Martin; Číp, Ondřej; Pham, Minh Tuan; Lešundák, Adam; Pravdová, Lenka; Buchta, Zdeněk.
2017-06-01
The air refractive index is an important parameter in interferometric length measurements, since it substantially affects the measurement accuracy. We present a refractive index of air measurement method based on monitoring the phase difference between the ambient air and vacuum inside a permanently evacuated double-spaced cell. The cell is placed in one arm of the Michelson interferometer equipped with two light sources—red LED and HeNe laser, while the low-coherence and laser interference signals are measured separately. Both phase and group refractive indices of air can be calculated from the measured signals. The method was experimentally verified by comparing the obtained refractive index values with two different techniques.
Evidence of nonuniform phase-diffusion in a bad-cavity laser
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kuppens, S.J.M.; Exter, M.P. van; Duin, M. van
1995-07-01
The quantum-limited linewidth of a short HeNe 3.39-{micro}m laser was measured and seen to increase with increasing nonuniformity of the intracavity intensity distribution. Experiments were done inside as well as outside the bad-cavity regime; in this regime the polarization of the gain medium can not be adiabatically eliminated but acts as a memory. Good quantitative agreement with theory is obtained inside as well as outside the bad-cavity regime. The effect of nonuniformity is well described by the longitudinal Petermann K-factor. The bad-cavity and nonuniformity effects can be separated from each other as predicted by theory.
Silicon carbide novel optical sensor for combustion systems and nuclear reactors
NASA Astrophysics Data System (ADS)
Lim, Geunsik; Kar, Aravinda
2014-09-01
Crystalline silicon carbide is a wide bandgap semiconductor material with excellent optical properties, chemical inertness, radiation hardness and high mechanical strength at high temperatures. It is an excellent material platform for sensor applications in harsh environments such as combustion systems and nuclear reactors. A laser doping technique is used to fabricate SiC sensors for different combustion gases such as CO2, CO, NO and NO2. The sensor operates based on the principle of semiconductor optics, producing optical signal in contrast to conventional electrical sensors that produces electrical signal. The sensor response is measured with a low power He-Ne or diode laser.
Method for measuring visual resolution at the retinal level.
Liang, J; Westheimer, G
1993-08-01
To measure the intrinsic resolving capacity of the retinal and neural levels of vision, we devised a method that creates two lines with controllable contrast on the retina. The line separation can be varied at will, down to values below those achievable with conventional optical techniques. Implementation of the method with use of a He-Ne laser leads to a procedure that permits analysis of the performance of the human visual apparatus.
Detection of irradiation induced reactive oxygen species production in live cells
NASA Astrophysics Data System (ADS)
Gao, Bo; Zhu, Debin
2006-09-01
Reactive oxygen species (ROS) is thought to play an important role in cell signaling of apoptosis, necrosis, and proliferation. Light irradiation increases mitochondrial reactive oxygen species (ROS) production and mediates its intracellular signaling by adjusting the redox potential in tumor cells. Mitochondria are the main source of ROS in the living cell. Superoxide anions (0 II - are likely the first ROS generated in the mitochondria following radiation damage, and then convert to hydrogen peroxide (H II0 II), hydroxyl radical (•OH), and singlet oxygen (10 II), etc. Conventional methods for research ROS production in mitochondria mostly use isolated mitochondria rather than mitochondria in living cells. In this study, a highly selective probe to detect mitochondrial 0 II - in live cells, MitoSOX TM Red, was applied to quantify the mitochondrial ROS production in human lung adenocarcinoma cells (ASTC-a-1) with laser scanning microscope (LSM) after ultraviolet C (UVC) and He-Ne laser irradiation. Dichiorodihydrofluoresein diacetate (DCFHDA), a common used fluorescent probe for ROS detection without specificity, were used as a comparison to image the ROS production. The fluorescent image of MItoSOX TM Red counterstained with MitoTracker Deep Red 633, a mitochondria selective probe, shows that the mitochondrial ROS production increases distinctly after UVC and He-Ne laser irradiation. DCFH-DA diffuses labeling throughout the cell though its fluorescence increases markedly too. In conclusion, the fluorescent method with MitoSOX TM Red reagent is proved to be a promising technique to research the role of ROS in radiation induced apoptosis.
Investigation of the low-level modulated light action
NASA Astrophysics Data System (ADS)
Antonov, Sergei N.; Sotnikov, V. N.; Koreneva, L. G.
1994-07-01
Now there exists no clear complete knowledge about mechanisms and pathways by which low level laser bioactivation works. Modulated laser light action has been investigated two new ways: dynamical infrared thermography and computing image of living brain. These ways permit observation in real time laser action on peripheral blood flow, reflex reactions to functional probes, thermoregulation mechanisms as well as brain electrical activity changes of humans. We have designed a universal apparatus which produced all regimes of the output laser light. It has a built-in He-Ne laser with an acousto-optic modulator and an infrared GaAs laser. The device provided spatial combination of both the light beams and permitted us to irradiate an object both separately and simultaneously. This research shows that the most effective frequencies range from several to dozens of hertz. The duty factor and frequency scanning are also important. On the basis of these results in Russian clinics new treatment methods using modulated light are applied in practical neurology, gynecology, etc.
NASA Astrophysics Data System (ADS)
Li, Lu-Ke; Zhang, Shen-Feng
2018-03-01
Put forward a kind of three-dimensional vibration information technology of vibrating object by the mean of five laser beam of He-Ne laser, and with the help of three-way sensor, measure the three-dimensional laser vibration developed by above mentioned technology. The technology based on the Doppler principle of interference and signal demodulation technology, get the vibration information of the object, through the algorithm processing, extract the three-dimensional vibration information of space objects, and can achieve the function of angle calibration of five beam in the space, which avoid the effects of the mechanical installation error, greatly improve the accuracy of measurement. With the help of a & B K4527 contact three axis sensor, measure and calibrate three-dimensional laser vibrometer, which ensure the accuracy of the measurement data. Summarize the advantages and disadvantages of contact and non-contact sensor, and analysis the future development trends of the sensor industry.
Biostimulation effects of low-energy laser radiation on yeast cell suspensions
NASA Astrophysics Data System (ADS)
Anghel, Sorin; Stanescu, Constantin S.; Giosanu, Dana; Neagu, Ionica; Savulescu, Geta; Iorga-Siman, Ion
2000-02-01
This paper presents work to determine the effects produced by low energy laser radiation on the metabolism and growth of a yeast cell suspension. As experimental material, we used young yeast culture in liquid medium, then distributed on a solid medium, to obtain isolated colonies. As laser source, we used a He-Ne laser, and the irradiation was made with different exposure times. Form each irradiated material, a sample of white grape sterile must was sowed, that has fermented at 18 divided by 20 degrees C for 10 divided by 15 days, after that some properties was tested. Some microscopic studies were also made. The results prove some influence of low energy laser irradiation, which can induce mutations, with new properties of the irradiated material. These mutations can be obtained in a positive sense, with new and important perspectives in wine industry. Also, we observed an inhibitory effect of the laser radiation on the yeast cell growth, due, probably to the too high values of the exposure.
NASA Technical Reports Server (NTRS)
Kassel, P. C., Jr.
1978-01-01
A fail safe light activated switch was used as an emergency control link at the Langley Vortex Research Facility. In this facility aircraft models were towed through a still air test chamber by a gasoline powered vehicle which was launched from one end of a 427-meter track and attained velocities to 31 m/sec in the test chamber. A 5 mW HeNe laser with a mechanical copper provided a connecting link with the moving tow vehicle on which a silicon photodiode receiver with a specially designed amplifier provided a fail safe switching action. This system provided an emergency means of stopping the vehicle by turning off the laser to interrupt the power to the vehicle ignition and brake release systems.
Instrument for measuring dispersional distortions in optical fibers and cables
NASA Astrophysics Data System (ADS)
Alishev, Y. V.; Maryenko, A. A.; Smirnov, Y. V.; Uryadov, V. N.; Sinkevich, V. I.
1985-03-01
An instrument was developed and built for measuring the dispersional distortions in optical fibers and cables on the basis of pulse widening. The instrument consists of a laser as a light source, a master oscillator, an optical transmitter, an optical shunt with mode mixer, an optical receiver, a fiber length measuring device, a smoothly adjustable delay line, and a stroboscopic oscillograph. The optical transmitter contains a semiconductor laser with GaAs-GaAlAs diheterostructure and modulator with pulse generating avalanche-breakdown transistors. The optical receiver contains a germanium photodiode with internal amplification and photoreceiver amplifier with microwave bipolar germanium transistors. Matching of the instrument to the tested fiber line is done by passing radiation into the latter from an auxiliary small He-Ne laser through a directional coupler.
Pulsed writing of solid state holograms.
NASA Technical Reports Server (NTRS)
Gaylord, T. K.; Rabson, T. A.; Tittel, F. K.; Quick, C. R.
1973-01-01
The pulsed writing of volume holograms in lithium niobate is reported, both with 200-nsec and 20-nsec duration pulses. This information is of particular interest in high capacity information storage applications since it indicates that writing times at least as short as 20-nsec are readily possible. A series of pulses was used in each case, and the diffraction efficiency was monitored using a He-Ne laser operating at 6328 A and aligned to its corresponding Bragg angle.
Applications of high power lasers. [using reflection holograms for machining and surface treatment
NASA Technical Reports Server (NTRS)
Angus, J. C.
1979-01-01
The use of computer generated, reflection holograms in conjunction with high power lasers for precision machining of metals and ceramics was investigated. The Reflection holograms which were developed and made to work at both optical wavelength (He-Ne, 6328 A) and infrared (CO2, 10.6) meet the primary practical requirement of ruggedness and are relatively economical and simple to fabricate. The technology is sufficiently advanced now so that reflection holography could indeed be used as a practical manufacturing device in certain applications requiring low power densities. However, the present holograms are energy inefficient and much of the laser power is lost in the zero order spot and higher diffraction orders. Improvements of laser machining over conventional methods are discussed and addition applications are listed. Possible uses in the electronics industry include drilling holes in printed circuit boards making soldered connections, and resistor trimming.
Characterization of CNRS Fizeau wedge laser tuner
NASA Technical Reports Server (NTRS)
1984-01-01
A fringe detection and measurement system was constructed for use with the CNRS Fizeau wedge laser tuner, consisting of three circuit boards. The first board is a standard Reticon RC-100 B motherboard which is used to provide the timing, video processing, and housekeeping functions required by the Reticon RL-512 G photodiode array used in the system. The sampled and held video signal from the motherboard is processed by a second, custom fabricated circuit board which contains a high speed fringe detection and locating circuit. This board includes a dc level discriminator type fringe detector, a counter circuit to determine fringe center, a pulsed laser triggering circuit, and a control circuit to operate the shutter for the He-Ne reference laser beam. The fringe center information is supplied to the third board, a commercial single board computer, which governs the data collection process and interprets the results.
Intravascular low-intensity He-Ne laser irradiation therapy on idiopathic edema
NASA Astrophysics Data System (ADS)
Gao, Yunqing; Liu, T. C.; Tang, Xiang-Jun
1998-11-01
194 patients with psoriasis were treated by intravascular low level laser irradiation combined with Vit C 2.0g iv and O2 inhale to the nose. An hour once a day, for 5-40 times, and 13.06 times in average, ten times with 4-7 days intervals. The results: cured 23 cases, good effected 61 cases, improved 110 cases, relapsed 10 cases. Curative effect was related to treatment times, cured and good effected 5 times 12.5 percent, 10 times 31 percent, 15 times 94 percent. A matched control group in 17 patients was treated by drug. The results: good effected 1 case, improved 13 cases, not effected 3 cases.
NASA Astrophysics Data System (ADS)
Kim, Jisoo; Kim, SeJin; Nguyen, Tan Tai; Lee, Renee; Li, Tiehua; Yun, Changhyun; Ham, Youngeun; An, Seong Soo A.; Ju, Heongkyu
2016-05-01
We present a real-time quantitative immunoassay to detect fibrinogen in the blood plasma of Alzheimer's disease patients using multimode fiber optical sensors in which surface plasmon resonance (SPR) was employed. Nanometer-thick bimetals including silver and aluminum were coated onto the core surface of the clad-free part (5 cm long) of the fiber for SPR excitation at the He-Ne laser wavelength of 632.8 nm. The histidine-tagged peptide was then coated on the metal surface to immobilize the fibrinogen antibody for the selective capture of fibrinogen among the proteins in the patient blood plasma. The SPR fiber optical sensor enabled quantitative detection of concentrations of fibrinogen from the different human patient blood at a detection limit of ˜20 ng/ml. We also observed a correlation in the fibrinogen concentration measurement between enzyme-linked immunosorbent assay and our SPR fiber-based sensors. This suggests that the presented SPR fiber-based sensors that do not rely on the use of labels such as fluorophores can be used for a real-time quantitative assay of a specific protein such as fibrinogen in a human blood that is known to contain many other kinds of proteins together.
Photodynamic Treatment versus Antibiotic Treatment on Helicobacter pylori Using RAPD-PCR
NASA Astrophysics Data System (ADS)
El-Batanouny, M. H.; Amin, R. M.; Ibrahium, M. K.; El Gohary, S.; Naga, M. I.; Salama, M. S.
2009-09-01
Helicobacter pylori is one of the most common causes of chronic bacterial infections in humans and is important in the pathogenesis of gastrointestinal disease, such as duodenal ulcer, gastric ulcer, Gastric adenocarcinoma, and lymphoma. Gastric adenocarcinoma remains one of the leading causes of cancer death in the world. The objective of this study was to assess the effect of photodynamic treatment and medication treatment of Helicobacter pylori using RAPD-PCR. The lethal photosensitization effect was determined by mixing suspensions of H.pylori with Toluidine blue O (TBO) and plating out on blood agar before irradiation with Helium neon (He-Ne) 632.8 nm. The susceptibility of Helicobacter pylori isolates to metronidazole and azithromycin were examined by E-test. Nine random primers were used to screen genetic polymorphism in DNA of different H.pylori groups. Six of them produced RAPD products while three failed to generate any product. The resulting data showed that, although the overall genetic differences between control groups and laser treated groups was higher than that between control groups and azithromycin treated groups yet it still law genetic variability. The main cause of cell death of PDT using TBO as a photosensitizer was mainly cell wall and cytoplasmic membrane.
1.55 µm emission from a single III-nitride top-down and site-controlled nanowire quantum disk
NASA Astrophysics Data System (ADS)
Chen, Qiming; Yan, Changling; Qu, Yi
2017-07-01
InN/InGaN single quantum well (SQW) was fabricated on 100 nm GaN buffer layer which was deposited on GaN template by plasma assisted molecular beam epitaxy (PA-MBE). The In composition and the surface morphology were measured by x-ray diffusion (XRD) and atom force microscope (AFM), respectively. Afterwards, the sample was fabricated into site-controlled nanowires arrays by hot-embossing nano-imprint lithography (HE-NIL) and ultraviolet nanoimprint lithography (UV-NIL). The nanowires were uniform along the c-axis and aligned periodically as presented by scanning electron microscope (SEM). The single nanowire showed disk-in-a-wire structure by high angle annular dark field (HAADF) and an In-rich or Ga deficient region was observed by energy dispersive x-ray spectrum (EDXS). The optical properties of the SQW film and single nanowire were measured using micro photoluminescence (µ-PL) spectroscopy. The stimulating light wavelength was 632.8 nm which was emitted from a He-Ne laser and the detector was a liquid nitrogen cooled InGaAs detector. A blue peak shift from the film material to the nanowire was observed. This was due to the quantum confinement Stark Effect. More importantly, the 1.55 µm emission was given from the single disk-in-a-wire structure at room temperature. We believe the arrays of such nanowires may be useful for quantum communication in the future.
NASA Astrophysics Data System (ADS)
Ding, Ai-Hua; Chen, Hui-Ling
1993-03-01
The effect of laser on anti-early pregnancy in rabbits showed that laser in combination with HPD could induce necrosis of blastocysts and complete absorption. The anti-fertility efficiency of the combined treatment was more effective than that of the He-Ne laser or the HPD treatment alone. The fluorescence spectrum of HPD determined by PNQ3 showed that its affinity to embryonic tissue was about 4 times greater than that to uterine tissue. This may underlie the mechanisms of anti-early pregnancy of the laser. The operation of artificial abortion is a routine method to terminate early pregnancy. Though it is simple and easy, its syndrome and complications can not be absolutely avoided. Many antifertility drugs have been reported, however, they often bring in general reaction. Our present work is to explore a new way of anti-early pregnancy in rabbits by means of the light inhibitory and light sensitive effects of laser. It is a quite safe and painless treatment without expanding and scraping of the uterus.
Fast IR laser mapping ellipsometry for the study of functional organic thin films.
Furchner, Andreas; Sun, Guoguang; Ketelsen, Helge; Rappich, Jörg; Hinrichs, Karsten
2015-03-21
Fast infrared mapping with sub-millimeter lateral resolution as well as time-resolved infrared studies of kinetic processes of functional organic thin films require a new generation of infrared ellipsometers. We present a novel laboratory-based infrared (IR) laser mapping ellipsometer, in which a laser is coupled to a variable-angle rotating analyzer ellipsometer. Compared to conventional Fourier-transform infrared (FT-IR) ellipsometers, the IR laser ellipsometer provides ten- to hundredfold shorter measurement times down to 80 ms per measured spot, as well as about tenfold increased lateral resolution of 120 μm, thus enabling mapping of small sample areas with thin-film sensitivity. The ellipsometer, equipped with a HeNe laser emitting at about 2949 cm(-1), was applied for the optical characterization of inhomogeneous poly(3-hexylthiophene) [P3HT] and poly(N-isopropylacrylamide) [PNIPAAm] organic thin films used for opto-electronics and bioapplications. With the constant development of tunable IR laser sources, laser-based infrared ellipsometry is a promising technique for fast in-depth mapping characterization of thin films and blends.
NASA Astrophysics Data System (ADS)
Lee, Jun Ho; Hwang, Sunglyoung; Jeong, Dohwan; Hong, Jinsuk; Kim, Youngsoo; Kim, Yeonsoo; Kim, Hyunsook
2017-09-01
We report an innovative simple alignment method for a VNIR spectrometer in the wavelength region of 400-900 nm; this device is later combined with fore-optics (a telescope) to form a f/2.5 hyperspectral imaging spectrometer with a field of view of +/-7.68°. The detector at the final image plane is a 640×480 charge-coupled device with a 24 μm pixel size. We first assembled the fore-optics and the spectrometer separately and then combined them via a slit co-located on the image plane of the fore-optics and the object plane of the spectrometer. The spectrometer was assembled in three steps. In the initial step, the optics was simply assembled with an optical axis guiding He-Ne laser. In the second step, we located a pin-hole on the slit plane and a Shack-Hartmann sensor on the detector plane. The wavefront errors over the full field were scanned simply by moving the point source along the slit direction while the Shack-Hartmann sensor was constantly conjugated to the pin-hole position by a motorized stage. Optimal alignment was then performed based on the reverse sensitivity method. In the final stage, the pin-hole and the Shack-Hartmann sensor were exchanged with an equispaced 10 pin-hole slit called a field identifier and a detector. The light source was also changed from the laser (single wavelength source) to a krypton lamp (discrete multi-wavelength source). We were then easily able to calculate the distortion and keystone on the detector plane without any scanning or moving optical components; rather, we merely calculated the spectral centroids of the 10 pin-holes on the detector. We then tuned the clocking angles of the convex grating and the detector to minimize the distortion and keystone. The final assembly was tested and found to have an RMS WFE < 90 nm over the entire field of view, a keystone of 0.08 pixels, a smile of 1.13 pixels and a spectral resolution of 4.32 nm.
NASA Astrophysics Data System (ADS)
Jayaprakash, P.; Sangeetha, P.; Kumari, C. Rathika Thaya; Caroline, M. Lydia
2017-08-01
A nonlinear optical bulk single crystal of L-methionine admixtured D-mandelic acid (LMDMA) has been grown by slow solvent evaporation technique using water as solvent at ambient temperature. The crystallized LMDMA single crystal subjected to single crystal X-ray diffraction study confirmed monoclinic system with the acentric space group P21. The FTIR analysis gives information about the modes of vibration in the various functional groups present in LMDMA. The UV-visible spectral analysis assessed the optical quality and linear optical properties such as extinction coefficient, reflectance, refractive index and from which optical conductivity and electric susceptibility were also evaluated. The frequency doubling efficiency was observed using Kurtz Perry powder technique. A multiple shot laser was utilized to evaluate the laser damage threshold energy of the crystal. Discrete thermodynamic properties were carried out by TG-DTA studies. The hardness, Meyer's index, yield strength, elastic stiffness constant, Knoop hardness, fracture toughness and brittleness index were analyzed using Vickers microhardness tester. Layer growth pattern and the surface defect were examined by chemical etching studies using optical microscope. Fluorescence emission spectrum was recorded and lifetime was also studied. The electric field response of crystal was investigated from the dielectric studies at various temperatures at different frequencies. The third-order nonlinear optical response in LMDMA has been investigated using Z-scan technique with He-Ne laser at 632.8 nm and nonlinear parameters such as refractive index (n2), absorption coefficient (β) and susceptibility (χ3) investigated extensively for they are in optical phase conjucation, high-speed optical switches and optical dielectric devices.
Time and Temperature Stability of Silver-Coated Ceramics for Hydrogen Maser Resonant Cavities
1988-12-01
observations. EXPERIMENTAL TECHNIQUE Samples of Cervit C-101 (Owens-Illinois Corp.), Zerodur (Schott Glass Corp.) and ULE (Corning Glass Works) were...created using a He-Ne laser interferometerl41. The fringe patterns were photographed, manually digitized, and analyzed by a computer that fits a series...Material ES l~ (101°~/m2) Zerodur 9.1 0.24 Cervit C101 9.2 ULE 6.8 RESULTS SAMPLE CURVATURE Fig. 1 shows the curvature, as expressed by the
Fiber specklegram sensors sensitivities at high temperatures
NASA Astrophysics Data System (ADS)
Rodriguez-Cobo, L.; Lomer, M.; Lopez-Higuera, J. M.
2015-09-01
In this work, the sensitivity of Fiber Specklegram Sensors to high temperatures (up to 800ºC) have been studied. Two multimode silica fibers have been introduced into a tubular furnace while a HeNe laser source was launched into a fiber edge, projecting speckle patterns to a commercial webcam. A computer generated different heating and cooling sweeps while the specklegram evolution was recorded. The achieved results exhibit a remarkably linearity in FSS's sensitivity for temperatures under 800ºC, following the thermal expansion of fused silica.
2012-05-01
instrument was equipped with deuterated triglycine sulfide and mercury-cadmium-telluride ( HgCdTe ) detectors and was capable of obtaining spectra with...helium-neon [HeNe] laser zero-crossing frequency) using the HgCdTe detector . Absorbance spectra of the vapor effluent were computed using background...weak [a = 0.00021 (umol/mol) ’m ’, which gave a prediction of A ~ 0.001] and close to the detector cutoff (root mean square [RMS] noise = 0.0002 A
Lethal photosensitization of periodontal pathogens by a red-filtered Xenon lamp in vitro.
Matevski, Donco; Weersink, Robert; Tenenbaum, Howard C; Wilson, Brian; Ellen, Richard P; Lépine, Guylaine
2003-08-01
The ability of Helium-Neon (He-Ne) laser irradiation of a photosensitizer to induce localized phototoxic effects that kill periodontal pathogens is well documented and is termed photodynamic therapy (PDT). We investigated the potential of a conventional light source (red-filtered Xenon lamp) to activate toluidine blue O (TBO) in vitro and determined in vitro model parameters that may be used in future in vivo trials. Porphyromonas gingivalis 381 was used as the primary test bacterium. Treatment with a 2.2 J/cm2 light dose and 50 micro g/ml TBO concentration resulted in a bacterial kill of 2.43 +/- 0.39 logs with the He-Ne laser control and 3.34 +/- 0.24 logs with the lamp, a near 10-fold increase (p = 0.028). Increases in light intensity produced significantly higher killing (p = 0.012) that plateaued at 25 mW/cm2. There was a linear relationship between light dose and bacterial killing (r2 = 0.916); as light dose was increased bacterial survival decreased. No such relationship was found for the drug concentrations tested. Addition of serum or blood at 50% v/v to the P. gingivalis suspension prior to irradiation diminished killing from approximately 5 logs to 3 logs at 10 J/cm2. When serum was washed off, killing returned to 5 logs for all species tested except Bacteroides forsythus (3.92 +/- 0.68 logs kill). The data indicate that PDT utilizing a conventional light source is at least as effective as laser-induced treatment in vitro. Furthermore, PDT achieves significant bactericidal activity in the presence of serum and blood when used with the set parameters of 10 J/cm2, 100 mW/cm2 and 12.5 micro g/ml TBO.
Laser Materials and Laser Spectroscopy - A Satellite Meeting of IQEC '88
NASA Astrophysics Data System (ADS)
Wang, Zhijiang; Zhang, Zhiming
1989-03-01
The Table of Contents for the book is as follows: * Laser Materials * Laser Site Spectroscopy of Transition Metal Ions in Glass * Spectroscopy of Chromium Doped Tunable Laser Materials * Spectroscopic Properties of Nd3+ Ions in LaMgAl11O19 Crystal * Spectral Study and 2.938 μm Laser Emission of Er3+ in the Y3Al5O12 Crystal * Raman-infrared Spectra and Radiationless Relaxation of Laser Crystal NdAl3(BO3)4 * A Study on HB and FLN in BaFCl0.5Br0.5:Sm2+ at 77K * Pair-pumped Upconversion Solid State Lasers * CW Upconversion Laser Action in Neodymium and Erbium doped Solids * Ultra-high Sensitive Upconversion Fluorescence of YbF3 Doped with Trace Tm3+ and Er3+ * The Growth and Properties of NYAB and EYAB Multifunctional Crystal * Study on Fluorescence and Laser Light of Er3+ in Glass * Growth and Properties of Single Crystal Fibers for Laser Materials * A Study on the Quality of Sapphire, Ruby and Ti3+ Doped Sapphire Grown by Temperature Gradient Technique (TGT) and Czochralski Technique (CZ) * The Measurement of Output Property of Ti3+ Al2O3 Laser Crystal * An Xα Study of the Laser Crystal MgF2 : V2+ * Q-switched NAB Laser * Miniature YAG Lasers * Study of High Efficiency {LiF}:{F}^-_2 Color Center Crystals * Study on the Formation Conditions and Optical Properties of (F2+)H Color Center in NaCl:OH- Crystals * Novel Spectroscopic Properties of {LiF}:{F}^+_3 - {F}_2 Mixed Color Centers Laser Crystals * Terraced Substrate Visible GaAlAs Semiconductor Lasers with a Large Optical Cavity * The Temperature Dependence of Gain Spectra, Threshold Current and Auger Recombination in InGaAsP-InP Double Heterojunction Laser diode * Time-resolved Photoluminescence and Energy Transfer of Bound Excitons in GaP:N Crystals * Optical Limiting with Semiconductors * A Critical Review of High-efficiency Crystals for Tunable Lasers * Parametric Scattering in β - BaB2O4 Crystal Induced by Picosecond Pulses * Generation of Picosecond Pulses at 193 nm by Frequency Mixing in β - BaB2O4 * Mixing Frequency Generation of 271.0 - 291.5 nm in β - BaB2O4 * Low Temperature Absorption Steps Near Ultraviolet Intrinsic Edge in Beta Barium Metaborate * The Growth and Properties of BaTiO3 Crystals * High-order Phenomena Accompanied with Self-pumped Phase Conjugation in BaTiO * Growth and Laser Damage Estimation of Potassium Dihydrogen Phosphate Crystals for Laser Fusion * Noncritically Phase-matched KTP for Diode-pumped Lasers (400-700 nm) * Potassium Titanyl Phosphate (KTP): Properties and New Applications * A Kind of New Defect in KTP Crystal and its SHG Enhanced Effect * Nucleation and Growth of the Non-linear Optical Crystal Potassium Pentaborate Tetrahydrate * Quasi-periodic Oscillations in Photoinduced Conical Light Scattering from LiNbO3 : Fe Crystals * Laser Excited Photoreflectance of GaxIn1-xAs/InP Multiple Quantum Wells * Growth, Spectroscopic Properties and Applications of Doped LiNbO3 Crystals * Photorefractive and Photovoltaic Effect in Doped LiNbO3 * Recent Advances in Photorefractive Nonlinear Optics * Study on the Doubling-frequency and Anti-photorefractive Property of Heavily Magnesium-doped Lithium-rich Lithium Niobate Crystals * A New Technique for Increasing Two-wave Mixing Gain in Photorefractive Bi12SiO20 Crystals * Experimental Proof: There Existing Another Mechanism of Photorefractive Index in Crystal Ce-SBN * Effect of Crystal Annealing on Holographic Recording in Bismuth Silicon Oxide * Two Wave Coupling in KNbO3 Photorefractive Crystal * Photorefractive Effects in Nd-Doped Ferroelectric (KxNa1-x)0.4-(SryBa1-y)0.8 Nb2O6 Single Crystal * High Pressure Raman Spectra and the Effect of Pressure to the Ferroelastic Phase Transition in LnP5O15 * Time-delay Four-wave Mixing with Incoherent Light in Absorption Bands Treated as a Multi-level System * Pulsed Laser Induced Dislocation Structure in Lithium Fluoride Single Crystals * Laser Spectroscopy * Nonclassical Radiation from Single-atom Oscillators * Laser Spectroscopic Studies of Molecules in Highly Excited Vibrational State * Investigation of the Stark Effect in Xenon Autoionizing Rydberg Series with the Use of Coherent Tunable XUV Radiation * Laser Spectroscopy of Autoionising 5 dnf J = 4.5 Rydberg Series of Ba I * Resonance Photoionization Spectroscopy of Atoms: Autoionization and Highly Excited States of Kr and U * Stark Spectra of Strontium and Calcium Atoms * Observation of Bidirectional Stimulated Radiation at 330 nm, 364 nm and 718 nm with 660 nm Laser Pumping in Sodium Vapour * Study of Molecular Rydberg States and their Discriminations in Na2 * The Measurement of the High Excited Spectra of Samarium by using Stepwise Laser Excitation Method * Product Analysis in the Reaction of the Two-photon Excited Xe(5p56p) States with Freons * Photoionization Spectra of Ca and Sr Atoms above the Classical Field-ionization Threshold * Effect of Medium Background on the Hydrogen Spectrum * Photoemission and Photoelectron Spectra from Autoionizing Atoms in Strong Laser Field * Natural Radiative Lifetime Measurements of High-lying States of Samarium * Two-step Laser Excitation of nf Rydberg States in Neutral Al and Observation of Stark Effect * Measurements of Excited Spectra of the Refractory Metal Elements using Discharge Synchronized with the Laser Pulse * Multiphoton Ionization of Atomic Lead at 1.06μ * Kinetic Processes in the Electron-beam pumped KrF Laser * Laser-induced Fluorescence of Zn2 Excimer * Calculation of Transition Intensity in Heteronuclear Dimer NaK: Comparison with Experiment * Laser-induced Fluorescence of CCl2 Carbene * Study of Multiphoton Ionization Spectrum of Benzene and Two-photon Absorption Cross Section * Dicke Narrowing of N2O Linewidth Perturbed by N2 at 10 μm Band * Polyatomic Molecular Ions Studied by Laser Photodissociation Spectroscopy * Transverse-optically Pumped Ultraviolet S2 Laser * Multiphoton Ionization of Propanal by High Power Laser * UV MPI Mass Spectroscopy and Dynamics of Photodissociation of SO2 * Multiphoton Ionization-fragmentation Patterns of Ethylamine and Dimethylamine Isomers * Cars Measurements of SF6 Pumped by a CO2 Laser Pulse * Angular Dependence of Phase Conjugation of CO2 Laser on SF6 Gas * Resolution of Stretching-vibrational and Translational Raman Bands of Liquid Water by Means of Polarization Four-photon Spectroscopy * Laser-produced Plasma as an Effective Source for X-Ray Spectroscopy * Rotational Structure of the Low Lying Electronic States of Samarium Monoxide * Effects of Poling and Stretching on Second-harmonic Generation in Amorphous Vinylidene Cyanide/Vinyl Acetate Copolymer * Laser-induced Spectroscopy of Cardiovascular Tissues * Laser-excited Malignancy Autofluorescence for Tumour Malignancy Investigation and its Origin * A Study on Several Hematoporphyrin Derivatives by Time-resolved Spectroscopy * Research on Strong Field Processes with a Subpicosecond 400 GW Ultraviolet Source * Growth, Decay and Quenching of Stimulated Raman Scattering in Transparent Liquid Droplets * Layer Condensed Ammonia Studied by Photoacoustic Spectroscopy * High Efficiency Raman Conversion of XeCl Laser Radiation in Lead Vapor * Combined Effect of Stimulated Scattering and Phase Modulation on Generation of Supercontinum * Resonant Multiwave Mixing in Sodium Vapor * High Pressure Brillouin Scattering in Liquid Toluene * Optical Nonlinearities and Bistability in Gold Colloid * Sum-frequency Generation for Surface Vibrational Spectroscopy * Optical Studies of Molecule/Surface Interactions * Optical Second Harmonic Generation with Coupled Surface Plasmons from a Multi-layer Silver/Quartz Grating * Evidence of Silver Cluster and its Role in Surface Enhanced Raman Scattering (SERS) * Study on Cold-evaporated Silver Surfaces with Second-harmonic-generation * Study of Optical Second-harmonic-generation at Metal Surface with Polarization States * Spectroscopic Studies of J-Aggregates of Pseudoisocyanine in Molecular Monolayers in the Range 300 to 20 K * Study of Polymerization of Langmuir-Blodgett Monolayer by Surface Enhanced Raman Scattering * Dynamics of Laser-induced Etching of Si(III) Surface of Chlorine * Fourier Transform Heterodyne Spectroscopy of Liquid Interfaces * Generation of High Power UV Femtosecond Pulses * Femtosecond Photon Echoes * Transition Radiation of Femtosecond Optical Pulses * Observation of DFWN in a Saturable Absorber inside the CPM Ring Dye Laser Cavity * Study on the Induced Spectral Superbroadening of Ultrafast Laser Pulse in a Nonlinear Medium * Laser Cooling and Trapping of Atoms * Femtosecond Absorption Spectroscopy of Primary Processes in Bacterial Photosynthesis Reaction Centers * Observation of the Motion of Slow Atoms in a Standing Wave Field * The Interrelation between the Optical Properties and the MBE Growth Control of Quantum Well Structures * Ionic Excimers * Optical SHG Study on Polymerization of Langmuir-Blodgett Molecular Layers * Weak Localization of Light * Statistical Fragmentation Patterns of Metastable Ion: Comparison with Experiment * Oxygeneration Reaction of Cerium with XeCl Laser * Measurement of Verdet Coefficient and Magneto-optic Spectroscopy in terms of Beats * Study on Rhodamine 6G/Xylene and Red B Laser Dye Mixture System * Ultranarrow Absorption Resonances of Cold Particles and their Application in Spectroscopy and Optical Frequency Standards * The Dynamics of Ion Clouds in Paul Traps: Implications for Frequency Standard Applications * Frequency Stability Measurement of Zeeman Stabilized He-Ne Laser * Multi-wavelength CW He-Ne Laser and its Frequency Stabilization * Efficient Isotope Separation using Semiconductor Lasers * Multi-beam Circularly Polarized Holography * Ring Laser Opticity Meter * Improved Rademacher Functions and Rademacher Transform * Note
NASA Astrophysics Data System (ADS)
Zhao, Ping
The Rydberg constant {rm R }_infty is determined to a very high accuracy of 3 parts in 10^{10 } by a direct comparison of the four hydrogen and deuterium Balmer-beta transitions with a standard laser from the National Bureau of Standards. This experiment is now the most precise measurement for {rm R}_infty and approaches the limits of accuracy for wavelength or frequency measurements in the visible region. The result is {rm R}_infty = 109 737.315 73 (3) {rm cm}^{-1} with the definition of the meter: c = 299 792 458 m/sec. The experiment also yields the following results: The fine structure splittings 4{rm P}_ {1/2} rightarrow {rm 4P}_{3/2} in H: 1370.9 (3) MHz and in D: 1371.8 (3) MHz. The isotope shifts between H and D in the transitions {rm 2S}_{1/2} rightarrow {rm 4P}_{1/2}: 167 752.4 (3) MHz and {rm 2S}_{1/2 } rightarrow {rm 4P}_{3/2}: 167 753.3 (3) MHz. The experiment utilizes atomic beam laser spectroscopy. A beam of atomic hydrogen (or deuterium) is excited by electron bombardment to the metastable {rm 2S }_{1/2} state and is detected by a secondary electron emission detector. A chopped cw dye laser beam crosses the atomic beam at an angle of 90^circ to eliminate Doppler broadening. The metastables are quenched by laser excitation to {rm 4P}_{1/2} or {rm 4P}_{3/2 } states. The signal is monitored by a lock -in amplifier with the chopper as reference. An iodine (^{127}{ rm I}_2) stabilized helium-neon (He-Ne) laser is the primary standard with an accuracy of 1.6 times 10^{ -10}. Another He-Ne laser is locked to the standard laser with a variable offset frequency controlled by an oscillator. A frequency chain is established by locking together a dye laser, a piezoelectrically controlled measuring etalon and the offset laser. This chain allows the dye laser to scan across the Balmer-beta line in a precisely controllable manner. The lineshape and offset frequency are recorded simultaneously. Possible sources of systematic shifts and errors are carefully investigated. Hydrogen energy levels are calculated according to most recent values of physical constants. {rm R}_infty is obtained by comparing the measured and calculated hydrogen Balmer-beta transition. The result is in good agreement with the two most recent, but less precise experiments.
Photomask applications of traceable atomic force microscope dimensional metrology at NIST
NASA Astrophysics Data System (ADS)
Dixson, Ronald; Orji, Ndubuisi G.; Potzick, James; Fu, Joseph; Allen, Richard A.; Cresswell, Michael; Smith, Stewart; Walton, Anthony J.; Tsiamis, Andreas
2007-10-01
The National Institute of Standards and Technology (NIST) has a multifaceted program in atomic force microscope (AFM) dimensional metrology. Three major instruments are being used for traceable measurements. The first is a custom in-house metrology AFM, called the calibrated AFM (C-AFM), the second is the first generation of commercially available critical dimension AFM (CD-AFM), and the third is a current generation CD-AFM at SEMATECH - for which NIST has established the calibration and uncertainties. All of these instruments have useful applications in photomask metrology. Linewidth reference metrology is an important application of CD-AFM. We have performed a preliminary comparison of linewidths measured by CD-AFM and by electrical resistance metrology on a binary mask. For the ten selected test structures with on-mask linewidths between 350 nm and 600 nm, most of the observed differences were less than 5 nm, and all of them were less than 10 nm. The offsets were often within the estimated uncertainties of the AFM measurements, without accounting for the effect of linewidth roughness or the uncertainties of electrical measurements. The most recent release of the NIST photomask standard - which is Standard Reference Material (SRM) 2059 - was also supported by CD-AFM reference measurements. We review the recent advances in AFM linewidth metrology that will reduce the uncertainty of AFM measurements on this and future generations of the NIST photomask standard. The NIST C-AFM has displacement metrology for all three axes traceable to the 633 nm wavelength of the iodine-stabilized He-Ne laser. One of the important applications of the C-AFM is step height metrology, which has some relevance to phase shift calibration. In the current generation of the system, the approximate level of relative standard uncertainty for step height measurements at the 100 nm scale is 0.1 %. We discuss the monitor history of a 290 nm step height, originally measured on the C-AFM with a 1.9 nm (k = 2) expanded uncertainty, and describe advances that bring the step height uncertainty of recent measurements to an estimated 0.6 nm (k = 2). Based on this work, we expect to be able to reduce the topographic component of phase uncertainty in alternating aperture phase shift masks (AAPSM) by a factor of three compared to current calibrations based on earlier generation step height references.
Editorial special issue on "Laser Doppler vibrometry"
NASA Astrophysics Data System (ADS)
Vanlanduit, Steve; Dirckx, Joris
2017-12-01
The invention of the laser in 1960 has opened up many opportunities in the field of measurement science and technology. Just a few years after the invention of the laser, a novel fluid flow measurement technique based on the Doppler effect was introduced: at that moment the laser Doppler anemometer or shortly LDA [1] was born. The technique enabled fluid velocity measurement by using the light of a He-Ne beam which was scattered by very small polystyrene spheres entrained in the fluid. Later on, in the late nineteen seventees it was recognized that the detection of the Doppler frequency shift that occurs when light is scattered by a moving surface can also be used to measure the vibration velocity of an object. The instrument to perform these vibration measurements was called the laser Doppler vibrometer or LDV [2]. In the last decades several technological advances were made in the field of laser Doppler vibrometry. The result is that nowadays, velocity measurements of fluids (using LDA) and vibrating objects (using LDV) are performed in many challenging applications in different fields (microelectronics, civil structures, biomedical engineering, material science, etc.).
NASA Astrophysics Data System (ADS)
Koev, K.; Avramov, L.; Borissova, E.
2018-03-01
The objective of this study was to examine long-term effects of low-level laser therapy (LLLT) in patients with age-related macular degeneration (AMD). The research was implemented for a period of five years. For LLLT, a He-Ne Laser with continuous emission at 633 nm (0.1 mW/cm2) was used in patients with AMD of all stages (dry to wet exudative forms were included). In total, 33 patients (16 men and 17 women – 66 eyes) with AMD of various stages and a mean age of 68.7 ± 4.2 years were included in the study. Progressive, exudative AMD was diagnosed in 8 eyes. 58 eyes had drusen or were depigmented. Laser radiation was applied transpupillary to the macula for six times for three minutes once in two days; 22 patients with AMD (44 eyes) were randomly selected to receive mock treatment (control group 10 men and 12 women with a mean age of 69.3 ± 4.8 years). The visual acuity was followed for a five-year period. The perimetry and Amsler test were used to screen central scotomas. The fluorescein angiography of AMD and the control groups was examined. The visual acuity remained unchanged in all patients in the control group. There was a statistically significant increase in the visual acuity (p<0.001, end of study versus baseline) for AMD patients for the period of five years after the treatment. The edema and hemorrhage in the patients with progressive, exudative AMD significantly decreased. No side effects were observed during the therapy. The prevalence of metamorphopsia, scotoma in AMD group was reduced. In conclusion, this study shows that LLLT may be a novel long-lasting therapeutic option for both forms of AMD. It is a highly-effective treatment that results in a long-term improvement of the visual acuity.
Biological applications and effects of optical masers
NASA Astrophysics Data System (ADS)
Ham, William T., Jr.; Mueller, Harold A.; Williams, Ray C.; Geeraets, Walter J.; Ruffolo, John J., Jr.
1988-02-01
Research experiments and projects pertaining to the ocular hazards of lasers and other optical sources are reviewed and discussed in some detail. Early studies to determine threshold retinal damage in the rabbit from ruby and neodymium lasers are described and followed by more elaborate experiments with monkeys using the He;Ne laser. A comparison between threshold retinal lesions in human volunteers, monkeys and rabbits is given. Retinal damage in the rhesus monkey is evaluated in terms of visual acuity. Quantitative data on solar retinitis as determined in the rhesus monkey are provided and the effects of wavelength on light toxicity are evaluated for eight monochromatic laser lines. Experiments performed at Los Alamos to evaluate the ocular effects and hazards of picosecond and nanosecond pulses of radiation from CO2 and HF lasers are described. A list of published papers describing the above research is included. The HF laser effects on the rabbit cornea were very similar to those caused by exposure to the CO2 laser. The energy from the CO2 and HF lasers is completely absorbed in the superficial layers of the cornea, creating a sharp sonic or shock wave which can disrupt the epithelial cells but does not penetrate to the stroma.
Straightness measurement using laser beam straight datum
NASA Astrophysics Data System (ADS)
Uchikoshi, Junichi; Shimada, Shoichi; Ikawa, Naoya; Komura, Akio
1995-08-01
Using the direction stabilized laser beam as a physical straight datum, instead of the tangible reference surface, a method is proposed for the measurement of an error motion of a slide table and/or surface profile of mechanical components. A specially designed 2D position sensor/compensator for laser beam center is developed combining a quadrant photo-diode (QPD) position sensor for beam center and the piezo-compensator which compensates the beam shift from the center of QPD. By the use the sensor/compensator proposed, the positional and angular fluctuations of laser beam path is evaluated with nanometric resolution. Combining the sensor with the piezo-driven mirror compensator, the directional stabilizer for the laser beam is also designed in the same manner as the sensor/compensator. The stabilized He-Ne laser beam can be used as the metrological datum of straightness within the accuracy of 2 X 10 -8 rad. By mounting the position sensor/compensator on a slide table, the carriage with working distance of 1 m is so designed and built as to move straight along the stabilized laser beam. The carriage can be used as a mechanical straight datum with the accuracy equivalent to the laser beam stability.
A simple apparatus for quick qualitative analysis of CR39 nuclear track detectors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gautier, D. C.; Kline, J. L.; Flippo, K. A.
2008-10-15
Quantifying the ion pits in Columbia Resin 39 (CR39) nuclear track detector from Thomson parabolas is a time consuming and tedious process using conventional microscope based techniques. A simple inventive apparatus for fast screening and qualitative analysis of CR39 detectors has been developed, enabling efficient selection of data for a more detailed analysis. The system consists simply of a green He-Ne laser and a high-resolution digital single-lens reflex camera. The laser illuminates the edge of the CR39 at grazing incidence and couples into the plastic, acting as a light pipe. Subsequently, the laser illuminates all ion tracks on the surface.more » A high-resolution digital camera is used to photograph the scattered light from the ion tracks, enabling one to quickly determine charge states and energies measured by the Thomson parabola.« less
Amplitude and polarization asymmetries in a ring laser
NASA Technical Reports Server (NTRS)
Campbell, L. L.; Buholz, N. E.
1971-01-01
Asymmetric amplitude effects between the oppositely directed traveling waves in a He-Ne ring laser are analyzed both theoretically and experimentally. These effects make it possible to detect angular orientations of an inner-cavity bar with respect to the plane of the ring cavity. The amplitude asymmetries occur when a birefringent bar is placed in the three-mirror ring cavity, and an axial magnetic field is applied to the active medium. A simplified theoretical analysis is performed by using a first order perturbation theory to derive an expression for the polarization of the active medium, and a set of self-consistent equations are derived to predict threshold conditions. Polarization asymmetries between the oppositely directed waves are also predicted. Amplitude asymmetries similar in nature to those predicted at threshold occur when the laser is operating in 12-15 free-running modes, and polarization asymmetry occurs simultaneously.
Characterization of CNRS Fizeau wedge laser tuner
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
A fringe detection and measurement system was constructed for use with the CNRS Fizeau wedge laser tuner, consisting of three circuit boards. The first board is a standard Reticon RC-100 B motherboard which is used to provide the timing, video processing, and housekeeping functions required by the Reticon RL-512 G photodiode array used in the system. The sampled and held video signal from the motherboard is processed by a second, custom-fabricated circuit board which contains a high-speed fringe detection and locating circuit. This board includes a dc level-discriminator-type fringe detector, a counter circuit to determine fringe center, a pulsed lasermore » triggering circuit, and a control circuit to operate the shutter for the He-Ne reference laser beam. The fringe center information is supplied to the third board, a commercial single board computer, which governs the data-collection process and interprets the results.« less
He-Ne Laser Acupuncture: Treatment Of Rhinopharyngeal Infection.
NASA Astrophysics Data System (ADS)
Dussert, Dr.
1984-03-01
Ladies and gentlemen, 23 months ago I treated the following emergency cases in my surgery : 1) A man of 53 suffering from dyspnoea (clinically speaking he was a case of exniratory bradypnoea). He had just been hospitalised for a month and had been undergoing cortisone treatment. I made him sit, and b/ irradiating each of the stellar ganglions for six minutes by laser at an impulse wave length of 6 in low frequency I freed up this patient, who started to breathe normally. 2) Some time after this : A child of 7 came to see me. He was suffering from an attack of asthma. I passed each of the stellar ganglions under the laser at impulse wave length 6 in low frequency for 4 minutes. The child witnes ed his attack calming down. In view of these two cases I decided to organise a research project.
Laser Scanner For Automatic Storage
NASA Astrophysics Data System (ADS)
Carvalho, Fernando D.; Correia, Bento A.; Rebordao, Jose M.; Rodrigues, F. Carvalho
1989-01-01
The automated magazines are beeing used at industry more and more. One of the problems related with the automation of a Store House is the identification of the products envolved. Already used for stock management, the Bar Codes allows an easy way to identify one product. Applied to automated magazines, the bar codes allows a great variety of items in a small code. In order to be used by the national producers of automated magazines, a devoted laser scanner has been develloped. The Prototype uses an He-Ne laser whose beam scans a field angle of 75 degrees at 16 Hz. The scene reflectivity is transduced by a photodiode into an electrical signal, which is then binarized. This digital signal is the input of the decodifying program. The machine is able to see barcodes and to decode the information. A parallel interface allows the comunication with the central unit, which is responsible for the management of automated magazine.
NASA Astrophysics Data System (ADS)
Cornejo, A.
2011-04-01
The field of Optics in Mexico, related with research projects, started at the Instituto de Astronomía, UNAM, since 1960. Therefore, the first projects and papers were mainly dedicated to astronomical instruments. After sometime, other projects started other areas of Optics as for example the production of He-Ne gas lasers, thin films deposits, experiments in holography, programs for general optical design, and theory and experiments for testing optical components and instruments.
Efficiency-enhanced photon sieve using Gaussian/overlapping distribution of pinholes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sabatyan, A.; Mirzaie, S.
2011-04-10
A class of photon sieve is introduced whose structure is based on the overlapping pinholes in the innermost zones. This kind of distribution is produced by, for example, a particular form of Gaussian function. The focusing property of the proposed model was examined theoretically and experimentally. It is shown that under He-Ne laser and white light illumination, the focal spot size of this novel structure has considerably smaller FWHM than a photon sieve with randomly distributed pinholes and a Fresnel zone plate. In addition, secondary maxima have been suppressed effectively.
Athermal laser treatment of the diabetic leg
NASA Astrophysics Data System (ADS)
Ignat, P.; Suteanu, S.; Brojbeanu, Gabriela; Vasiliu, Virgil V.
1995-03-01
This work shows the result obtained in the medical clinic of the `Dr. I. Cantacuzino Hospital' on a lot of 43 diabetic patients using the `LASSIS' devices composed of a He-Ne laser and 4 semiconductor lasers. The 43 patients showed various clinic pictures of a diabetic leg (diabetic arteriopathy and neuropathy) 16 of the lot showed an arteriopathy with claudication and a decrease of pulses oscillometrically measurements, 15 had ulceration and a beginning of gangrene and the other 12 showed a plantary boring ill. There has been achieved an amelioration of the oscillometric index of the claudication while walking the amelioration of local circulation, together with the limitation of the necrosis. For the boring ill, there has been achieved the acceleration of the granulating and epithelization process avoiding surgeries, suppuration and cutaneous plasties. The response to the laser treatment was compared to the response to the classic treatment (vasodilatation surgery unstrapping, antibiotherapy) on a proving lot. We appreciated that the cicatrization and local vasodilatation with athermal laser treatment should be a hope for the treatment of patients suffering of diabetic arteriopathy and neuropathy.
NASA Astrophysics Data System (ADS)
Panjehpour, Masoud; Overholt, Bergein F.; Frazier, Donita L.; Klebanow, Edward R.
1991-05-01
Conventional hyperthermia treatment of superficial tumors in the oral cavity is difficult due to inability in accessing the lesion. A new hyperthermia technique employing near infrared Nd:YAG irradiation delivered through an optical fiber is introduced for heating oral and nasal tumors in animals. This system consisted of an Nd:YAG laser, a He-Ne laser, a computer controlled optical shutter, an interstitial thermometer, computer and a printer. The tumors were heated via surface illumination of the lesion. A thermocouple implanted in the base of the tumor provided temperature feedback for laser energy regulation. Three spontaneously occurring canine (two squamous cell carcinoma on the gum, one pigmented melanoma on the hard palate) and one feline tumor (squamous cell carcinoma on the nose) have been treated with the Nd:YAG laser-induced hyperthermia delivered following radiation therapy. The tumor temperature was maintained between 43.2-43.5 degree(s)C for one hour. Nd:YAG hyperthermia allowed efficient delivery of heat to veterinary oral and nasal lesions otherwise impossible to treat with conventional heating techniques.
NASA Astrophysics Data System (ADS)
Biswas, Subrata; Kumbhakar, Pathik
2018-01-01
In this report, we have demonstrated the refractive index and temperature-sensing abilities of polyvinylpyrrolidone (PVP)-protected silver nanostructures of triangular, connected and plate-like shapes. Interestingly, these nanostructures even after 2 and ½ years of syntheses showed plasmonic-sensing ability of temperature in the temperature range of 283-333 K. Also, refractive index (R.I.) sensing has been demonstrated in the aged samples and obtained the highest R.I. sensitivity of 306 nm/RIU in one of the sample. The synthesized samples have been kept in dark (inside desiccators) intentionally for the extended period of 2 and ½ years after synthesis and monitored intermittently their UV-Vis absorption and photoluminescence (PL) emission characteristics to check the functionally of the aged silver nanostructures. It has been found the samples remain well dispersed in different solvents and can forbid agglomeration even in 0.25 M NaCl solution. We have also demonstrated here fabrication of a flexible and transparent thin film of the synthesized samples in polyvinyl alcohol (PVA) matrix and investigated its low power continuous-wave (CW) nonlinear optical properties using spatial self-phase modulation (SSPM) technique. The nonlinear refractive index ( n 2) value of the film has been determined to be 5.6 × 10- 6 cm2/W at the He-Ne laser wavelength of 632.8 nm. In this report we have demonstrated temperature and R.I. sensing and also it has been demonstrated that the synthesized samples remain functional even after 2 and ½ years of synthesis. Also, samples may find potential applications in nonlinear optical phase modulation devices.
NASA Astrophysics Data System (ADS)
Pichan, Karuppasamy; Muthu, Senthil Pandian; Perumalsamy, Ramasamy
2017-09-01
The organic single crystal of piperazinium bis(4-hydroxybenzenesulphonate) (P4HBS) was grown by slow evaporation solution technique (SEST) at room temperature. The lattice parameters of the grown crystal were confirmed by single crystal X-ray diffraction analysis. Functional groups of P4HBS crystal were confirmed by FTIR spectrum analysis. The optical quality of the grown crystal was identified by the UV-Vis NIR spectrum analysis. The grown crystal has good optical transmittance in the range of 410-1100 nm. In photoluminescence spectrum, sharp emission peaks are observed, which indicates the ultraviolet (UV) emission. The photoconductivity study reveals that the grown crystal has negative photoconductive nature. The thermal behaviour of the P4HBS crystal was investigated by thermogravimetric and differential thermal analysis (TG-DTA). The mechanical stability of grown crystal was analyzed and the indentation size effect (ISE) was explained by Hays-Kendall's (HK) approach and proportional specimen resistance model (PSRM). Chemical etching study was carried out and the etch pit density (EPD) was calculated. The dielectric constant (ε‧) and dielectric loss (tan δ) as a function of frequency were measured for the grown crystal. The solid state parameters such as valence electron, plasma energy, Penn gap and Fermi energy were evaluated theoretically for the P4HBS using the empirical relation. The estimated values are used to calculate the electronic polarizability. The third-order nonlinear optical properties such as nonlinear refractive index (n2), absorption co-efficient (β) and susceptibility (χ(3)) were studied by Z-scan technique at 632.8 nm using He-Ne laser.
High-sensitivity Raman spectrometer to study pristine and irradiated interstellar ice analogs.
Bennett, Chris J; Brotton, Stephen J; Jones, Brant M; Misra, Anupam K; Sharma, Shiv K; Kaiser, Ralf I
2013-06-18
We discuss the novel design of a sensitive, normal-Raman spectrometer interfaced to an ultra-high vacuum chamber (5 × 10(-11) Torr) utilized to investigate the interaction of ionizing radiation with low temperature ices relevant to the solar system and interstellar medium. The design is based on a pulsed Nd:YAG laser which takes advantage of gating techniques to isolate the scattered Raman signal from the competing fluorescence signal. The setup incorporates innovations to achieve maximum sensitivity without detectable heating of the sample. Thin films of carbon dioxide (CO2) ices of 10 to 396 nm thickness were prepared and characterized using both Fourier transform infrared (FT-IR) spectroscopy and HeNe interference techniques. The ν+ and ν- Fermi resonance bands of CO2 ices were observed by Raman spectroscopy at 1385 and 1278 cm(-1), respectively, and the band areas showed a linear dependence on ice thickness. Preliminary irradiation experiments are conducted on a 450 nm thick sample of CO2 ice using energetic electrons. Both carbon monoxide (CO) and the infrared inactive molecular oxygen (O2) products are readily detected from their characteristic Raman bands at 2145 and 1545 cm(-1), respectively. Detection limits of 4 ± 3 and 6 ± 4 monolayers of CO and O2 were derived, demonstrating the unique power to detect newly formed molecules in irradiated ices in situ. The setup is universally applicable to the detection of low-abundance species, since no Raman signal enhancement is required, demonstrating Raman spectroscopy as a reliable alternative, or complement, to FT-IR spectroscopy in space science applications.
NASA Astrophysics Data System (ADS)
Antony, Albin; Pramodini, S.; Poornesh, P.; Kityk, I. V.; Fedorchuk, A. O.; Sanjeev, Ganesh
2016-12-01
We present the studies on third-order nonlinear optical properties of Al doped ZnO thin films irradiated with electron beam at different dose rate. Al doped ZnO thin films were deposited on a glass substrate by spray pyrolysis deposition technique. The thin films were irradiated using the 8 MeV electron beam from microtron ranging from 1 kG y to 5 kG y. Nonlinear optical studies were carried out by employing the single beam Z-scan technique to determine the sign and magnitude of absorptive and refractive nonlinearities of the irradiated thin films. Continuous wave He-Ne laser operating at 633 nm was used as source of excitation. The open aperture Z-scan measurements indicated the sample displays reverse saturable absorption (RSA) process. The negative sign of the nonlinear refractive index n2 was noted from the closed aperture Z-scan measurements indicates, the films exhibit self-defocusing property due to thermal nonlinearity. The third-order nonlinear optical susceptibility χ(3) varies from 8.17 × 10-5 esu to 1.39 × 10-3 esu with increase in electron beam irradiation. The present study reveals that the irradiation of electron beam leads to significant changes in the third-order optical nonlinearity. Al doped ZnO displays good optical power handling capability with optical clamping of about ∼5 mW. The irradiation study endorses that the Al doped ZnO under investigation is a promising candidate photonic device applications such as all-optical power limiting.
NASA Astrophysics Data System (ADS)
Taguchi, Yoshio; Kurokawa, Yoshimochi; Ohara, Itaru; Ueki, Hamaichi; Inaba, Humio
1989-09-01
The first report of laser irradiation for wound healing was done by Mester, E., et al. in 1968. From their reports, we can get many knowledges and suggestions as for laser irradiation. At that time he used ruby laser (694.3 nm wave length) for surgical wounds and burns on the back skin of mice. The condition of irradiation was studied with energy density between 0.5-10 J/cm2 twice a week. As a result, they noticed 1 J/cm2 irradiation was effective for those wounds. After a few experimental reports, they published their clinical studies in 1975. Clinically, they used He-Ne laser (632.8 nm wave length) irradiation. Human leg ulcers due to peripheral circulatory disturbance were treated with energy density of 4 J/cm2 twice a week. And they got good results, obtaining complete healing in two-thirds of the cases. We became strongly stimulated by those reports. We have been studying the effect of light on experimental and clinical wound healing as well as on various kinds of biological phenomena since 1980. Particularly, its effect according to the difference of light has been studied. In October 1982, the first clinical case was tried by Argon laser (514.5 nm wave length) irradiation for therapeutic purpose. A man had a chronic ulcer of the left first toe due to Buerger's disease for 5 months. Surprizingly, on the 14th day after 6 treatments of the light irradiation, his ulcer completely healed. During these treatments, the patient noticed that the pain completely disappeared after 2 treatments. Fifty Argon laser treatments were carried out on clinical cases after these experiences, we reached to a conclusion that light irradiation stimulated something in the injured tissues and lead to good clinical results. Several studies concerning mechanism for these effects i.e. peripheral circulation, histology of granulation, cell proliferation, chemistry and other studies were carried out. From these investigations, peripheral circulation was improved when in those who were suffering from vascular disorders but was not effective in normal subjects. From a study of cellular electrophoretic mobility, irradiated G0G1 cells increased their mobility, but irradiated G2M cells decreased. These results suggested light irradiation contributed to homeostasis of living cells, tissues, and body. Experiments concerning the light sources, i.e. wave length, energy density and polarization were done. As a result, linear polarization and right circular polarization improved wound healing, but incoherent light itself did not. ,According to our studies, no distinguished differences among various kinds of wave length were noticed. And light irradiation with energy density was very effective between 2 to 6 J/cm2. We strongly suggest the role of coherency is very important to do light irradiation on the living body. In conclusion, we like to propose our new viewpoint. That is, the light irradiation should be discussed with the structure of high molecular substances in the living body.
Multiphase computer-generated holograms for full-color image generation
NASA Astrophysics Data System (ADS)
Choi, Kyong S.; Choi, Byong S.; Choi, Yoon S.; Kim, Sun I.; Kim, Jong Man; Kim, Nam; Gil, Sang K.
2002-06-01
Multi-phase and binary-phase computer-generated holograms were designed and demonstrated for full-color image generation. Optimize a phase profile of the hologram that achieves each color image, we employed a simulated annealing method. The design binary phase hologram had the diffraction efficiency of 33.23 percent and the reconstruction error of 0.367 X 10-2. And eight phase hologram had the diffraction efficiency of 67.92 percent and the reconstruction error of 0.273 X 10-2. The designed BPH was fabricated by micro photolithographic technique with a minimum pixel width of 5micrometers . And the it was reconstructed using by two Ar-ion lasers and a He-Ne laser. In addition, the color dispersion characteristic of the fabricate grating and scaling problem of the reconstructed image were discussed.
Paasch, Uwe; Wagner, Justinus A; Paasch, Hartmut W
2015-01-01
Alexandrite (755 nm) and diode lasers (800-810 nm) are commonly used for hair removal. The alexandrite laser technology is somewhat cumbersome whereas new diode lasers are more robust. Recently, alexandrite-like 755 nm wavelength diodes became available. To compare the efficacy, tolerability, and subject satisfaction of a 755 nm diode laser operated in conventional (HR) and non-conventional in-motion (SHR) modes with a conventional scanned alexandrite 755 nm laser for chest and axillary hair removal. A prospective, single-center, proof of principle study was designed to evaluate the safety, efficacy and handling of a 755 nm diode laser system in comparison to a standard alexandrite 755 nm scanning hair removal laser. The new 755 nm diode is suitable to be used in SHR and HR mode and has been tested for its safety, efficacy and handling in a volunteer with success. Overall, both systems showed a high efficacy in hair reduction (88.8% 755 nm diode laser vs. 77.7% 755 nm alexandrite laser). Also, during the study period, no severe adverse effects were reported. The new 755 nm diode laser is as effective and safe as the traditional 755 nm alexandrite laser. Additionally, treatment with the 755 nm diode laser with HR and SHR modes was found to be less painful.
NASA Astrophysics Data System (ADS)
Arumnika, N.; Kuswanto, H.
2018-04-01
This study aimed to determine the effect of curvature configuration to sensitivities and linearities of Polymer Optical Fiber (POF) water level sensor. POF type SH-4001-1.3 has been used in this study. The jacket of POF of 20 cm was removed. Transparent piped inserted by alcohol gel has been used to replace the jacket. This is head of a sensor. The head of a sensor is curved with variations of the specified path length, peel length, the width of curvature, the height of curvature and waveform. Configuration A (20 cm, 34 cm, 6 cm, 2 cm, 1 wave), configuration B (20 cm, 34 cm, 8 cm, 2 cm, 1 wave), configuration C (20 cm, 34 cm, 9 cm, 2 cm, ½ wave), configuration D (20 cm, 34 cm, 10 cm, 2 cm, ½ wave). The head of a sensor inserted into the water tank. The light source inserted to one end POF is a He-Ne laser light with a power of 5 mW and a wavelength of 632.8 nm. Power output at the other end received by the Optical Power Meter (OPM). The curvature configuration the head sensor of POF affects the output. Configuration A has good sensitivity, however good linearity given by configuration.
Sakota, Daisuke; Takatani, Setsuo
2012-05-01
Optical properties of flowing blood were analyzed using a photon-cell interactive Monte Carlo (pciMC) model with the physical properties of the flowing red blood cells (RBCs) such as cell size, shape, refractive index, distribution, and orientation as the parameters. The scattering of light by flowing blood at the He-Ne laser wavelength of 632.8 nm was significantly affected by the shear rate. The light was scattered more in the direction of flow as the flow rate increased. Therefore, the light intensity transmitted forward in the direction perpendicular to flow axis decreased. The pciMC model can duplicate the changes in the photon propagation due to moving RBCs with various orientations. The resulting RBC's orientation that best simulated the experimental results was with their long axis perpendicular to the direction of blood flow. Moreover, the scattering probability was dependent on the orientation of the RBCs. Finally, the pciMC code was used to predict the hematocrit of flowing blood with accuracy of approximately 1.0 HCT%. The photon-cell interactive Monte Carlo (pciMC) model can provide optical properties of flowing blood and will facilitate the development of the non-invasive monitoring of blood in extra corporeal circulatory systems.
NASA Astrophysics Data System (ADS)
Wieloszyńska, Aleksandra; StrÄ kowski, Marcin
2016-09-01
The profilometry plays a huge role in the most fields of science and technology. It allows to measure the profile of the surface with high-resolution. This technique is used in the fields like optic, electronic, medicine, automotive, and much more. The aim of the current work was to design and build optical profilometer based on the interference phenomena. The developed device has been working with He-Ne laser (632.8 nm). The optical parts have been chosen in order to reach the sized 2.0 mm x 1.6 mm of scanning area. The setup of the profilometer is based on Twyman-Green interferometer. Therefore, the phase distribution of the backreflected light from measured surface is recorded. The measurements are carried out with the aid of multiframe algorithms. In this approach we have used the Hariharan algorithm to obtain the exact value of the recorded phase. During tests, which have been carried out in order to check the functionality of the device, the interference patterns have been recoded and processed in order to obtain the 3D profile of measured surface. In this contribution the setup of the optical system, as well as signal processing methods are going to be presented. The brief discussion about the advantages and disadvantages, and usefulness of this approach will be carried out.
NASA Astrophysics Data System (ADS)
Mageshwari, P. S. Latha; Priya, R.; Krishnan, S.; Joseph, V.; Das, S. Jerome
2016-11-01
A third order nonlinear optical (NLO)single crystals of sodium succinate hexahydrate (SSH) (β phase) has been grown by a slow evaporation growth technique using aqueous solution at ambient temperature. The lattice parameters and morphology of SSH were determined by single crystal X-ray diffraction analysis. SSH crystallizes in centrosymmetric monoclinic system with space group P 21 / c and the crystalline purity was analyzed by powder X-ray diffraction analysis. The UV-vis-NIR spectrum reveals that the crystal is transparent in the entire visible region. The recorded FT-IR spectrum verified the presence of various functional groups in the material. NMR analysis of the grown crystal confirms the structural elucidation and detects the major and minor functional groups present in the title compound. ICP-OES analysis proved the presence of sodium in SSH. TG-DTA/DSCanalysis was used to investigate the thermal stability of the material. The dielectric permittivity and dielectric loss of SSH were carried out as a function of frequency for different temperatures and the results were discussed. The mechanical stability was evaluated from Vicker's microhardness test. The third order nonlinear optical properties of SSH has been investigated employing Z-scan technique with He-Ne laser operating at 632.8 nm wavelength.
Noninvasive detection of cardiovascular pulsations by optical Doppler techniques
NASA Astrophysics Data System (ADS)
Hong, HyunDae; Fox, Martin D.
1997-10-01
A system has been developed based on the measurement of skin surface vibration that can be used to detect the underlying vascular wall motion of superficial arteries and the chest wall. Data obtained from tissue phantoms suggested that the detected signals were related to intravascular pressure, an important clinical and physiological parameter. Unlike the conventional optical Doppler techniques that have been used to measure blood perfusion in skin layers and blood flow within superficial arteries, the present system was optimized to pick up skin vibrations. An optical interferometer with a 633-nm He:Ne laser was utilized to detect micrometer displacements of the skin surface. Motion velocity profiles of the skin surface near each superficial artery and auscultation points on a chest for the two heart valve sounds exhibited distinctive profiles. The theoretical and experimental results demonstrated that the system detected the velocity of skin movement, which is related to the time derivative of the pressure. The system also reduces the loading effect on the pulsation signals and heart sounds produced by the conventional piezoelectric vibration sensors. The system's sensitivity, which could be optimized further, was 366.2 micrometers /s for the present research. Overall, optical cardiovascular vibrometry has the potential to become a simple noninvasive approach to cardiovascular screening.
NASA Astrophysics Data System (ADS)
Tran, Lauren Christine
The Extraordinary Electroconductance (EEC) sensor has been previously demonstrated to have an electric field sensitivity of 3.05V/cm in a mesoscopic-scale structure fabricated at the center of a parallel plate capacitor. In this thesis, we demonstrate the first successful application of EEC sensors as electrochemical detectors of protein binding and biological molecule concentration. Using the avidin derivative, captavidin, in complex with the vitamin biotin, the change in four-point measured resistance with fluid protein concentration of bare EEC sensors was shown to increase by a factor of four in the presence of biomolecular binding as compared to baseline. Calculations for approximate field strengths introduced by a bound captavidin molecule are also presented. The development of Inverse-Extraordinary Optoconductance (I-EOC), an effect which occurs in nanoscale sensors, is also discussed. In the I-EOC effect, electron transport transitions from ballistic to diffusive with increasing light intensity. In these novel, room temperature optical detectors, the resistance is low at low light intensity and resistance increases by 9462% in a 250nm device mesa upon full illumination with a 5 mW HeNe laser. This is the inverse of bulk and mesoscopic device behavior, in which resistance decreases with increasing photon density.
NASA Astrophysics Data System (ADS)
Selvakumar, S.; Boobalan, Maria Susai; Anthuvan Babu, S.; Ramalingam, S.; Leo Rajesh, A.
2016-12-01
Single crystals of sodium para-nitrophenolate para-nitrophenol dihydrate (SPPD) were grown by slow evaporation technique and its structure has been studied by FT-IR, FT-Raman and single crystal X-ray diffraction techniques. The optical and electrical properties were characterized by UV-Vis spectrum, and dielectric studies respectively. SPPD was thermally stable up to 128 °C as determined by TG-DTA curves. Using the Kurtz-Perry powder method, the second-harmonic generation efficiency was found to be five times to that of KDP. Third-order nonlinear response was studied using Z-scan technique with a He-Ne laser (632.8 nm) and NLO parameters such as intensity dependent refractive index, nonlinear absorption coefficient and third-order susceptibility were also estimated. The molecular geometry from X-ray experiment in the ground state has been compared using density functional theory (DFT) with appropriate basis set. The first-order hyperpolarizability also calculated using DFT approaches. Stability of the molecule arising from hyperconjugative interactions leading to its nonlinear optical activity and charge delocalization were analyzed using natural bond orbital technique. HOMO-LUMO energy gap value suggests the possibility of charge transfer within the molecule. Based on optimized ground state geometries, Natural bond orbital (NBO) analysis was performed to study donor-acceptor interactions.
Arabski, Michał; Wasik, Sławomir; Piskulak, Patrycja; Góźdź, Natalia; Slezak, Andrzej; Kaca, Wiesław
2011-01-01
The aim of this study was to analysis of antibiotics (ampicilin, streptomycin, ciprofloxacin or colistin) release from agarose gel by spectrophotmetry and laser interferometry methods. The interferometric system consisted of a Mach-Zehnder interferometer with a He-Ne laser, TV-CCD camera, computerised data acquisition system and a gel system. The gel system under study consists of two cuvettes. We filled the lower cuvette with an aqueous 1% agarose solution with the antibiotics at initial concentration of antibiotics in the range of 0.12-2 mg/ml for spectrophotmetry analysis or 0.05-0.5 mg/ml for laser interferometry methods, while in the upper cuvette there was pure water. The diffusion was analysed from 120 to 2400 s with a time interval of deltat = 120 s by both methods. We observed that 0.25-1 mg/ml and 0,05 mg/ml are minimal initial concentrations detected by spectrophotometric and laser interferometry methods, respectively. Additionally, we observed differences in kinetic of antibiotic diffusion from gel measured by both methods. In conclusion, the laser interferometric method is a useful tool for studies of antibiotic release from agarose gel, especially for substances are not fully soluble in water, for example: colistin.
Choy, D S; Altman, P A; Case, R B; Trokel, S L
1991-06-01
The interaction of laser radiation with the nucleus pulposus from autopsy specimens of human intervertebral disks was evaluated at different wavelengths (193 nm, 488 nm & 514 nm, 1064 nm, 1318 nm, 2150 nm, 2940 nm, and 10600 nm). A significant correlation of linear least squares fit of the mass ablated as a function of incident energy was found for all lasers used except the Excimer at 193 nm. The 2940-nm Erbium:YAG laser was most efficient in terms of mass of disk ablated per joule in the limited lower range where this wavelength was observed. At higher energy levels, the CO2 laser in the pulsed mode was most efficient. However, the Nd:YAG 1064-nm and 1318-nm lasers are currently best suited for percutaneous laser disk decompression because of the availability of usable waveguides. Carbonization of tissue with the more penetrating Nd:YAG 1064-nm laser increases the efficiency of tissue ablation and makes it comparable to the Nd:YAG 1318-nm laser.
Yin, Jian; Han, Zhengfeng; Guo, Baofeng; Guo, Han; Zhang, Tongtong; Zeng, Yanjun; Ren, Longxi
2015-07-01
To compare the ablation ability of nucleus pulposus after 1,064 nm Nd:YAG laser and 980 nm diode laser radiation. Goat spine specimen (GSS) was radiated using Nd:YAG laser and 980 nm diode laser and then divided into five groups based on the final energy--200, 400, 600, 800 and 1,000 J groups. The ablation quality of nucleus pulposus after radiation was recorded. The ablation quality of GSS was greater at higher radiation energies in both lasers. When compared at the same energy level, the ablation quality of GSS was greater in 980 nm diode laser than in 1,064 nm Nd:YAG laser. Statistical significance was observed in 200 and 400 J groups (P < 0.05) and in 600, 800 and 1,000 J groups (P < 0.01). Radiation with 980 nm diode laser showed better ablation ability than 1,064 nm Nd:YAG laser.
Thermally stimulated nonlinear refraction in gelatin stabilized Cu-PVP nanocomposite thin films
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tamgadge, Y. S., E-mail: ystamgadge@gmail.com; Atkare, D. V.; Pahurkar, V. G.
2016-05-06
This article illustrates investigations on thermally stimulated third order nonlinear refraction of Cu-PVP nanocomposite thin films. Cu nanoparticles have been synthesized using chemical reduction method and thin films in PVP matrix have been obtained using spin coating technique. Thin films have been characterized by X-ray diffraction (XRD) and Ultraviolet-visible (UV-vis) spectroscopyfor structural and linear optical studies. Third order nonlinear refraction studies have been performed using closed aperture z-scan technique under continuous wave (CW) He-Ne laser. Cu-PVP nanocomposites are found to exhibit strong nonlinear refractive index stimulated by thermal lensing effect.
NASA Astrophysics Data System (ADS)
Zalesskaya, G. A.; Akulich, N. V.; Marochkov, A. V.; Laskina, O. V.; Mit'kovskaya, N. P.
2010-07-01
We have carried out a comprehensive analysis of the spectral characteristics of blood and blood components, gas-exchange and oximetry parameters for venous and arterial blood, central hemodynamic parameters, and the results of a complete blood count and chemistry panel before and after extracorporeal UV irradiation of the blood (UBI, ultraviolet blood irradiation) or intravenous exposure of blood to low-intensity emission from an He-Ne laser (LBI, laser blood irradiation). We have demonstrated the possibility of correcting the oxygentransport characteristics of blood by laser optical methods based on photodissociation of blood oxyhemoglobin. We have shown that the therapeutic effects initiated both by UBI and LBI are based on a single mechanism: a change in the balance between production of active oxygen species and their inhibition by antioxidants. The data obtained are of interest not only for studying the primary (molecular) mechanisms of action for photohemotherapy and their effect on processes occurring in the living body, but also can provide a basis for designing next-generation laser optical instruments and for development of not yet existing methods for assessing the therapeutic efficacy of photohemotherapy.
NASA Astrophysics Data System (ADS)
Zhang, Jie; Tao, Sha; Wang, Brian; Zhao, Jay
2017-02-01
In this paper, micro-processing of three kinds of super-hard materials of poly-crystal diamond (PCD)/tungsten-carbide (WC), CVD-diamond and cubic boron nitride (CNB) has been systematically studied using nanosecond laser (532nm and 355nm), and ultrafast laser (532nm and 515nm). Our purpose is to investigate a full laser micro-cutting solution to achieve a ready-to-use cutting tool insert (CTI). The results show a clean cut with little burns and recasting at edge. The cutting speed of 2-10mm/min depending on thickness was obtained. The laser ablation process was also studied by varying laser parameters (wavelength, pulse width, pulse energy, repetition rate) and tool path to improve cutting speed. Also, studies on material removal efficiency (MRE) of PCD/WC with 355nm-ns and 515nm-fs laser as a function of laser fluence show that 355nm-ns laser is able to achieve higher MRE for PCD and WC. Thus, ultrafast laser is not necessarily used for superhard material cutting. Instead, post-polishing with ultrafast laser can be used to clean cutting surface and improve smoothness.
NASA Astrophysics Data System (ADS)
Kucerova, Hana; Bartova, Jirina; Himmlova, Lucia; Dostalova, Tatjana
1997-12-01
The subject of this work follows changes of the sIgA and albumin levels in the saliva of the patients treated after the extraction of their lower molars with either diode or He-Ne biostimulatory laser, using different modulatory frequencies. The results were compared with the sIgA and albumin levels in the saliva of the control, i.e. not- treated group. Appropriately chosen laser beam modulatory frequency should influence the increase in the sIgA and albumin levels against the base level. In our study, this hypothesis was confirmed in the group treated with the frequency of 9000Hz. The changes of the levels of the watched markers versus the control group were however statistically insignificant. The aim of this study was to contribute to the evaluation of specific modulatory frequencies for therapeutical use in a given pathological cause of the oral cavity.
LaHaye, N. L.; Harilal, S. S.; Diwakar, P. K.; Hassanein, A.; Kulkarni, P.
2015-01-01
We investigated the role of femtosecond (fs) laser wavelength on laser ablation (LA) and its relation to laser generated aerosol counts and particle distribution, inductively coupled plasma-mass spectrometry (ICP-MS) signal intensity, detection limits, and elemental fractionation. Four different NIST standard reference materials (610, 613, 615, and 616) were ablated using 400 nm and 800 nm fs laser pulses to study the effect of wavelength on laser ablation rate, accuracy, precision, and fractionation. Our results show that the detection limits are lower for 400 nm laser excitation than 800 nm laser excitation at lower laser energies but approximately equal at higher energies. Ablation threshold was also found to be lower for 400 nm than 800 nm laser excitation. Particle size distributions are very similar for 400 nm and 800 nm wavelengths; however, they differ significantly in counts at similar laser fluence levels. This study concludes that 400 nm LA is more beneficial for sample introduction in ICP-MS, particularly when lower laser energies are to be used for ablation. PMID:26640294
Versatile microsecond movie camera
NASA Astrophysics Data System (ADS)
Dreyfus, R. W.
1980-03-01
A laboratory-type movie camera is described which satisfies many requirements in the range 1 microsec to 1 sec. The camera consists of a He-Ne laser and compatible state-of-the-art components; the primary components are an acoustooptic modulator, an electromechanical beam deflector, and a video tape system. The present camera is distinct in its operation in that submicrosecond laser flashes freeze the image motion while still allowing the simplicity of electromechanical image deflection in the millisecond range. The gating and pulse delay circuits of an oscilloscope synchronize the modulator and scanner relative to the subject being photographed. The optical table construction and electronic control enhance the camera's versatility and adaptability. The instant replay video tape recording allows for easy synchronization and immediate viewing of the results. Economy is achieved by using off-the-shelf components, optical table construction, and short assembly time.
Central nervous system transplantation benefited by low-level laser irradiation
NASA Astrophysics Data System (ADS)
Rochkind, S.; Lubart, Rachel; Wollman, Yoram; Simantov, Rabi; Nissan, Moshe; Barr-Nea, Lilian
1990-06-01
Effect of low-level laser irradiation on the central nervous system transplantation is reported. Ernbryonal brain allografts were transplanted into the brain of 20 adult rats and peripheral nerve graft transplanted into the severely injured spinal cord of 16 dogs. The operated wound of 10 rats and 8 dogs were exposed daily for 21 days to lowpower laser irradiation CW HeNe laser (35 mW, 632.8 run, energy density of 30 J/cm2 at each point for rats and 70 J/cm2 at each point for dogs). This study shows that (i) the low-level laser irradiation prevents extensive glial scar formation (a limiting factor in CNS regeneration) between embryonal transplants and host brain; (ii) Dogs made paraplegic by spinal cord injury were able to walk 3-6 months later. Recovery of these dogs was effected by the implantation of a fragment of autologous sciatic nerve at the site of injury and subsequently exposing the dogs to low-level laser irradiation. The effect of laser irradiation on the embryonal nerve cells grown in tissue culture was also observed. We found that low-level laser irradiation induced intensive migration of neurites outward of the aggregates 15-22 The results of the present study and our previous investigations suggest that low-level laser irradiation is a novel tool for treatment of peripheral and central nervous system injuries.
Arecibo Optical Laboratory Upgrade: imaging FPI first results
NASA Astrophysics Data System (ADS)
Noto, J.; Kerr, R. B.; Migliozzi, M. A.; Tepley, C. A.; Friedman, J.; Garcia, R.; Robles, E.; Waldrop, L. S.
2006-05-01
The Optical Laboratory at the Arecibo Observatory is being upgraded to permit remote operation, to improve Fabry-Perot Interferometer (FPI) sensitivity, and to permit FPI response in the near infrared. Integration of a 2048 x 2048 Andor CCD array into the existing low-resolution Fabry Perot Interferometer is complete. Remote operation and data acquisition for this FPI is accomplished by transition from the obsolete PDP-11 data acquisition system to PC-based, internet aware control. Another upgrade stage, adding a near-infrared focal plane array to a second FPI is scheduled for the fall of this year. Configured with a spectral resolution of 0.0086 nm at 656.3 nm, the low resolution FPI sampled the geocoronal Balmer-alpha emission during three new moon periods in November and December, 2005, and January, 2006. The latter two observation campaigns were conducted using the new remote control capability. The single etalon FPI produces three orders at the CCD plane corresponding to a full field-of-view of 0.92 degrees. The FPI Hadinger ring pattern is summed annularly, and the three orders are subsequently summed, producing an instrument sensitivity that is 43 times better than the previous single channel photomultiplier detection system. Raw detector response is corrected using both linear (chip bias) and non-linear techniques (flat-field) prior to ring-summing. A frequency stabilized HeNe laser at 632.8 nm is remotely operated to establish the FPI response function. Effective exospheric temperature and line profile asymmetries are determined after decomposition of the instrument response function from the measured airglow emission. Identification and climatological characterization of non-Maxwellian H distributions, with simultaneous quantification of H+ abundance and flow in the topside ionosphere by the Arecibo incoherent scatter radar, are measurements central to our goal of improved understanding of H on H+ charge exchange escape of H.
a Study of the Effects of Processing Chemistry on the Holographic Image Space.
NASA Astrophysics Data System (ADS)
Kocher, Clive Joseph
Available from UMI in association with The British Library. Processing methods for reflection and transmission holograms were evaluated with a view to minimising distortion in the images of small, metallic, near field subjects, whilst retaining optimum quality. The study was limited to recordings made with the HeNe laser (633 nm) in conjunction with the Agfa Gevaert 8E75 HD silver halide emulsion on glass or film support (5^{' '} x 4^{' '} format). Simple ray diagrams were used to help predict angular distortion arising from emulsion shrinkage for a two-dimensional model. The main conclusions are: (a) Serious distortion of the order of several millimetres, and loss of resolution will occur in the images of reflection holograms unless careful attention is given to processing procedures. Evidence supports the hypothesis that shrinkage due to processing causes the fringe system to collapse with a resultant change in inclination angle, and hence a distortion of the reconstructed image. Minimum distortion occurs with a laser reconstructed hologram processed in a high tanning developer and rehalogenating bleach, none being detected under the test conditions. (b) The same problem was not apparent for the transmission hologram due to a different fringe orientation, and within the limitations of the measuring system, no distortion was detected for any processing system. Comparative tests were made to evaluate the differences in performance for the Agfa 8E75 HD emulsion on plate and film support. Results show a significant increase in speed for film (as high as times4) and shrinkage (~3%), under all processing conditions. The advantages of using Phenidone based developers are shown. The report also includes a comprehensive background theory section covering basic concepts, silver halide recording material, holographic processing chemistry, distortion in holograms and pulsed laser holography. A review of previous work on phase holograms is given. Although primarily intended for measurement, this report contains useful information of benefit to display holography.
Comparative study of Nd:KGW lasers pumped at 808 nm and 877 nm
NASA Astrophysics Data System (ADS)
Huang, Ke; Ge, Wen-Qi; Zhao, Tian-Zhuo; He, Jian-Guo; Feng, Chen-Yong; Fan, Zhong-Wei
2015-10-01
The laser performance and thermal analysis of Nd:KGW laser continuously pumped by 808 nm and 877 nm are comparatively investigated. Output power of 670 mW and 1587 mW, with nearly TEM00 mode, are achieved respectively at 808 nm pump and 877 nm pump. Meanwhile, a high-power passively Q-switched Nd:KGW/Cr4+:YAG laser pumped at 877 nm is demonstrated. An average output power of 1495 mW is obtained at pump power of 5.22 W while the laser is operating at repetition of 53.17 kHz. We demonstrate that 877 nm diode laser is a more potential pump source for Nd:KGW lasers.
Clinical dental application of Er:YAG laser for Class V cavity preparation.
Matsumoto, K; Nakamura, Y; Mazeki, K; Kimura, Y
1996-06-01
Following the development of the ruby laser by Maiman in 1960, the Nd:YAG laser, the CO2 laser, the semiconductor laser, the He-Ne laser, excimer lasers, the argon laser, and finally the Er:YAG laser capable of cutting hard tissue easily were developed and have come to be applied clinically. In the present study, the Er:YAG laser emitting at a wavelength of 2.94 microns developed by Luxar was used for the clinical preparation of class V cavities. Parameters of 8 Hz and approx. 250 mJ/pulse maximum output were used for irradiation. Sixty teeth of 40 patients were used in this clinical study. The Er:YAG laser used in this study was found to be a system suitable for clinical application. No adverse reaction was observed in any of the cases. Class V cavity preparation was performed without inducing any pain in 48/60 cases (80%). All of the 12 cases that complained of mild or severe intraoperative pain had previously complained of cervical dentin hypersensibility during the preoperative examination. Cavity preparation was completed with this laser system in 58/60 cases (91.7%). No treatment-related clinical problems were observed during the follow-up period of approx. 30 days after cavity preparation and resin filling. Cavity preparation took between approx. 10 sec and 3 min and was related more or less to cavity size and depth. Overall clinical evaluation showed no safety problem with very good rating in 49 cases (81.7%).
NASA Astrophysics Data System (ADS)
Xu, Bin; Huang, Xiaoxu; Lan, Jinglong; Lin, Zhi; Wang, Yi; Xu, Huiying; Cai, Zhiping; Moncorgé, Richard
2016-07-01
Calibrated room temperature polarized emission spectra recorded between 850 and 1400 nm and nearly free from any reabsorption effect are presented for the first time. A laser output power of 2.35 W is obtained at 1063.45 nm with a laser slope efficiency of about 56% by pumping an uncoated Nd:LaF3 single crystal with a fiber-coupled laser diode at 790 nm inside a standard two-mirror linear laser cavity. True dual-wavelength laser operation on two orthogonally polarized laser lines around 1040 and 1065 nm as well as continuous laser wavelength tuning around 1040 nm, 1048 nm and 1064 nm are also achieved for the first time by using either an intracavity etalon or a birefringent filter. Laser operation is finally obtained around 1330.73 nm with a maximum output power of 0.18 W and a laser slope efficiency of about 4% and simultaneous dual-wavelength laser operation at 1329.04 and 1359.67 nm is demonstrated by using a glass etalon.
Recent development on high-power tandem-pumped fiber laser
NASA Astrophysics Data System (ADS)
Zhou, Pu; Xiao, Hu; Leng, Jinyong; Zhang, Hanwei; Xu, Jiangmin; Wu, Jian
2016-11-01
High power fiber laser is attracting more and more attention due to its advantage in excellent beam quality, high electricto- optical conversion efficiency and compact system configuration. Power scaling of fiber laser is challenged by the brightness of pump source, nonlinear effect, modal instability and so on. Pumping active fiber by using high-brightness fiber laser instead of common laser diode may be the solution for the brightness limitation. In this paper, we will present the recent development of various kinds of high power fiber laser based on tandem pumping scheme. According to the absorption property of Ytterbium-doped fiber, Thulium-doped fiber and Holmium-doped fiber, we have theoretically studied the fiber lasers that operate at 1018 nm, 1178 nm and 1150 nm, respectively in detail. Consequently, according to the numerical results we have optimized the fiber laser system design, and we have achieved (1) 500 watt level 1018nm Ytterbium-doped fiber laser (2) 100 watt level 1150 nm fiber laser and 100 watt level random fiber laser (3) 30 watt 1178 nm Ytterbium-doped fiber laser, 200 watt-level random fiber laser. All of the above-mentioned are the record power for the corresponded type of fiber laser to the best of our knowledge. By using the high-brightness fiber laser operate at 1018 nm, 1178 nm and 1150 nm that we have developed, we have achieved the following high power fiber laser (1) 3.5 kW 1090 nm Ytterbium-doped fiber amplifier (2) 100 watt level Thulium-doped fiber laser and (3) 50 watt level Holmium -doped fiber laser.
Zaleski-Larsen, Lisa A; Jones, Isabela T; Guiha, Isabella; Wu, Douglas C; Goldman, Mitchel P
2018-05-09
Few effective treatments exist for striae alba, which are the mature stage of stretch marks. To evaluate the efficacy of the nonablative fractional 1,565-nm Er:glass and the picosecond fractional 1,064/532-nm Nd:YAG lasers in the treatment of striae alba. Twenty subjects with striae alba on the bilateral abdomen were treated with either the nonablative fractional 1565-nm Er:glass or the picosecond fractional 1,064/532-nm Nd:YAG laser, with a total of 3 treatments 3 weeks apart. A 31% (1.25/4) texture improvement was noted for both the fractional 1,565-nm Er:glass laser and the picosecond fractional 1,064/532-nm Nd:YAG laser. The degree of atrophy was improved by 30% (1.19/4) with the 1,565-nm Er:glass laser and 35% (1.38/4) with the picosecond 1,064/532-nm Nd:YAG laser. A 48% (1.9/4) subject overall assessment of improvement was noted with the fractional 1565-nm Er:glass laser and 45% (1.8/4) improvement with the picosecond fractional 1,064/532-nm Nd:YAG laser. There was no significant change in striae density with either laser. The picosecond laser was rated as less painful during all 3 sessions (p = .002) and had a shorter healing time (p = .035). The nonablative fractional 1,565-nm Er:glass and the picosecond fractional 1,064/532-nm Nd:YAG lasers were equally efficacious in improving striae alba.
Fourier-Based Diffraction Analysis of Live Caenorhabditis elegans.
Magnes, Jenny; Hastings, Harold M; Raley-Susman, Kathleen M; Alivisatos, Clara; Warner, Adam; Hulsey-Vincent, Miranda
2017-09-13
This manuscript describes how to classify nematodes using temporal far-field diffraction signatures. A single C. elegans is suspended in a water column inside an optical cuvette. A 632 nm continuous wave HeNe laser is directed through the cuvette using front surface mirrors. A significant distance of at least 20-30 cm traveled after the light passes through the cuvette ensures a useful far-field (Fraunhofer) diffraction pattern. The diffraction pattern changes in real time as the nematode swims within the laser beam. The photodiode is placed off-center in the diffraction pattern. The voltage signal from the photodiode is observed in real time and recorded using a digital oscilloscope. This process is repeated for 139 wild type and 108 "roller" C. elegans. Wild type worms exhibit a rapid oscillation pattern in solution. The "roller" worms have a mutation in a key component of the cuticle that interferes with smooth locomotion. Time intervals that are not free of saturation and inactivity are discarded. It is practical to divide each average by its maximum to compare relative intensities. The signal for each worm is Fourier transformed so that the frequency pattern for each worm emerges. The signal for each type of worm is averaged. The averaged Fourier spectra for the wild type and the "roller" C. elegans are distinctly different and reveal that the dynamic worm shapes of the two different worm strains can be distinguished using Fourier analysis. The Fourier spectra of each worm strain match an approximate model using two different binary worm shapes that correspond to locomotory moments. The envelope of the averaged frequency distribution for actual and modeled worms confirms the model matches the data. This method can serve as a baseline for Fourier analysis for many microscopic species, as every microorganism will have its unique Fourier spectrum.
Programmable CGH on photochromic material using DMD
NASA Astrophysics Data System (ADS)
Alata, Romain; Pariani, Giorgio; Zamkotsian, Frederic; Lanzoni, Patrick; Bianco, Andrea; Bertarelli, Chiara
2016-07-01
Computer Generated Holograms (CGHs) are useful for wavefront shaping and complex optics testing, including aspherical and free-form optics. Today, CGHs are recorded directly with a laser or intermediates masks but allows only recording binary CGHs; binary CGHs are efficient but can reconstruct only pixilated images. We propose to use a Digital Micro-mirror Device (DMD) for writing binary CGHs as well as grayscale CGHs, able to reconstruct fulfilled images. DMD is actually studied at LAM, for generating programmable slit masks in multi-object spectrographs. It is composed of 2048x1080 individually controllable micro-mirrors, with a pitch of 13.68 μm. This is a real-time reconfigurable mask, perfect for recording CGHs. A first setup has been developed for hologram recording, where the DMD is enlightened with a collimated beam and illuminates a photosensible plate through an Offner relay, with a magnification of 1:1. Our set up resolution is 2-3 μm, leading to a CGH resolution equal to the DMD micro mirror size. In order to write and erase CGHs during test procedure or on request, we use a photochromic plate called PUR-GD71-50-ST developed at Politecnico di Milano. It is opaque at rest, and becomes transparent when it is illuminated with visible light, between 500 and 700 nm; then it can be erased by a UV flash. We choose to code the CGHs in equally spaced levels, so called stepped CGH. We recorded up to 1000x1000 pixels CGHs with a contrast greater than 50, knowing that the material is able to reach an ultimate contrast of 1000. A second bench has also been developed, dedicated to the reconstruction of the recorded images with a 632.8nm He-Ne laser beam. Very faithful reconstructions have been obtained. Thanks to our recording and reconstruction set-ups, we have been able to successfully record binary and stepped CGHs, and reconstruct them with a high fidelity, revealing the potential of this method for generating programmable/rewritable stepped CGHs on photochromic materials.
Ogura, Makoto; Sato, Shunichi; Ishihara, Miya; Kawauchi, Satoko; Arai, Tunenori; Matsui, Takemi; Kurita, Akira; Kikuchi, Makoto; Ashida, Hiroshi; Obara, Minoru
2002-01-01
We investigated the mechanism and characteristics of porcine myocardium tissue ablation in vitro with nanosecond 1,064- and 532-nm pulsed lasers at laser intensities up to approximately 5.0 GW/cm(2). Particular attention was paid to study the influence of the laser-induced plasma on the ablation characteristics. The applicability of these two lasers to transmyocardial laser revascularization (TMLR) was discussed. Porcine myocardium tissue samples were irradiated with 1,064- and 532-nm, Q-switched Nd:YAG laser pulses, and the ablation depths were measured. The temporal profiles of the laser-induced optical emissions were measured with a biplanar phototube. For the ablated tissue samples, histological analysis was performed with an optical microscope and a polarization microscope. The ablation efficiency at 1,064 nm was higher than that at 532 nm. The ablation threshold at 1,064 nm (approximately 0.8 GW/cm(2)) was lower than that at 532 nm (approximately 1.6 GW/cm(2)), in spite of the lower absorption coefficient being expected at 1,064 nm. For the 1,064-nm laser-ablated tissues, thermal damage was very limited, while damage presumably caused by the mechanical effect was observed in most of the cases. For the 1,064-nm laser ablation, the ablation threshold was equal to the threshold of the laser-induced optical emission (approximately 0.8 GW/cm(2)), while for the 532-nm laser ablation, the optical emission threshold ( approximately 2.4 GW/cm(2)) was higher than the ablation threshold. We considered that for the 1,064-nm laser ablation, the tissue removal was achieved through a photodisruption process at laser intensities of > approximately 0.8 GW/cm(2). At laser intensities of > 3.0 GW/cm(2), however, the ablation efficiency decreased; this can be attributed to the absorption of incoming laser pulses by the plasma. For the 532-nm laser ablation, the tissue removal was achieved through a photothermal process at laser intensities of > approximately 1.6 GW/cm(2). At laser intensities of > 2.4 GW/cm(2), a photodisruption process may also contribute to the tissue removal, in addition to a photothermal process. With regard to the ablation rates, the 1,064-nm laser was more suitable for TMLR than the 532-nm laser. We concluded that the 1,064-nm Q-switched Nd:YAG laser would be a potential candidate for a laser source for TMLR because of possible fiber-based beam delivery, its compact structure, cost effectiveness, and easy maintenance. Animal trials, however, have to be carried out to evaluate the influence of the tissue damage. Copyright 2002 Wiley-Liss, Inc.
Phase-Shifted Laser Feedback Interferometry
NASA Technical Reports Server (NTRS)
Ovryn, Benjie
1999-01-01
Phase-shifted, laser feedback interferometry is a new diagnostic tool developed at the NASA Lewis Research Center under the Advanced Technology Development (ATD) Program directed by NASA Headquarters Microgravity Research Division. It combines the principles of phase-shifting interferometry (PSI) and laser-feedback interferometry (LFI) to produce an instrument that can quantify both optical path length changes and sample reflectivity variations. In a homogenous medium, the optical path length between two points is the product of the index of refraction and the geometric distance between the two points. LFI differs from other forms of interferometry by using the laser as both the source and the phase detector. In LFI, coherent feedback of the incident light either reflected directly from a surface or reflected after transmission through a region of interest will modulate the output intensity of the laser. The combination of PSI and LFI has produced a robust instrument, based on a low-power helium-neon (HeNe) gas laser, with a high dynamic range that can be used to measure either static or oscillatory changes of the optical path length. Small changes in optical path length are limited by the fraction of a fringe that can be measured; we can measure nonoscillatory changes with a root mean square (rms) error of the wavelength/1000 without averaging.
Diode-pumped UV refractive surgery laser
NASA Astrophysics Data System (ADS)
Lin, Jui T.; Hwang, Ming-Yi; Huang, C. H.
1993-07-01
Ophthalmic applications of medical lasers have been extensively explored recently because of their market potential. Refractive surgical lasers represent one of the major development efforts due to the large population of eye disorders: about 160 million people in the USA and more than 2 billion worldwide. The first refractive laser developed was the ArF excimer laser at 193 nm in 1987 - 88 for a procedure called photorefractive keratectomy (PRK). More recently, solid state refractive lasers have also been explored for preliminary clinical trials. These lasers include Nd:YLF (picosecond at 1054 nm), doubled-Nd:YAG (nanosecond at 532 nm), Ho:YAG (microsecond at 2100 nm) and ultraviolet (UV) lasers generated from the harmonic of Ti:sapphire-laser (205 - 220 nm) and Nd:YAG (at 213 nm).
Histologic evaluation of laser lipolysis: pulsed 1064-nm Nd:YAG laser versus cw 980-nm diode laser.
Mordon, Serge; Eymard-Maurin, Anne Françoise; Wassmer, Benjamin; Ringot, Jean
2007-01-01
The use of the laser as an auxiliary tool has refined the traditional technique for lipoplasty. During laser lipolysis, the interaction between the laser and the fat produced direct cellular destruction before the suction, reduced bleeding, and promoted skin tightening. This study sought to perform a comparative histologic evaluation of laser lipolysis with the pulsed 1064-nm Nd:YAG laser versus a continuous 980-nm diode laser. A pulsed 1064-nm Nd:YAG (Smart-Lipo; Deka, Italy) and a CW 980-nm diode laser (Pharaon, Osyris, France) were evaluated at different energy settings for lipolysis on the thighs of a fresh cadaver. The lasers were coupled to a 600-microm optical fiber inserted in a 1-mm diameter cannula. Biopsy specimens were taken on irradiated and non-irradiated areas. Hematoxylin-erythrosin-safran staining and immunostaining (anti-PS100 polyclonal antibody) were performed to identify fat tissue damage. In the absence of laser exposures (control specimens), cavities created by cannulation were seen; adipocytes were round in appearance and not deflated. At low energy settings, tumescent adipocytes were observed. At higher energy settings, cytoplasmic retraction, disruption of membranes, and heat-coagulated collagen fibers were noted; coagulated blood cells were also present. For the highest energy settings, carbonization of fat tissue involving fibers and membranes was clearly seen. For equivalent energy settings, 1064-nm and 980-nm wavelengths gave similar histologic results. Laser lipolysis is a relatively new technique that is still under development. Our histologic findings suggest several positive benefits of the laser, including skin retraction and a reduction in intraoperative bleeding. The interaction of the laser with the tissue is similar at 980 nm and 1064 nm with the same energy settings. Because higher volumes of fat are removed with higher total energy, a high-power 980-nm diode laser could offer an interesting alternative to the 1064-nm Nd:YAG laser.
Endoluminal laser delivery mode and wavelength effects on varicose veins in an ex vivo model.
Massaki, Ane B M N; Kiripolsky, Monika G; Detwiler, Susan P; Goldman, Mitchel P
2013-02-01
Endovenous laser ablation (EVLA) has been shown to be effective for the elimination of saphenous veins and associated reflux. Mechanism is known to be heat related, but precise way in which heat causes vein ablation is not completely known. This study aimed to determine the effects of various endovenous laser wavelengths and delivery modes on ex vivo human vein both macroscopically and microscopically. We also evaluated whether protected-tip fibers, consisting of prototype silica fibers with a metal tube over the distal end, reduced vein wall perforations compared with non-protected-tip fibers. An ex vivo EVLA model with human veins harvested during ambulatory phlebectomy procedures was used. Six laser fiber combinations were tested: 810 nm continuous wave (CW) diode laser with a flat tip fiber, 810 CW diode laser with a protected tip fiber, 1,320 nm pulsed Nd:YAG laser, 1,310 nm CW diode laser, 1,470 nm CW diode laser, and 2,100 nm pulsed Ho:YAG laser. Perforation or full thickness necrosis of a portion of the vein wall was observed in 5/11 (45%), 0/11 (0%), 3/22 (14%), 7/11 (64%), 4/6 (67%), and 5/10 (50%) of cross-sections of veins treated with the 810 nm CW diode laser with a flat tip fiber, the 810 CW diode laser with a protected tip fiber, the 1,320 nm pulsed Nd:YAG laser, the 1,310 nm CW diode laser, the 1,470 nm CW diode laser, and the 2,100 nm pulsed Ho:YAG laser, respectively. Our results have shown that the delivery mode, pulsed Nd:YAG versus CW, may be just as important as the wavelength. Therefore, the 1,310 nm CW laser may not be equivalent to the 1,320 nm pulsed laser. In addition, protected 810 nm fibers may be less likely to yield wall perforations than their non-protected counterparts. Copyright © 2012 Wiley Periodicals, Inc.
Ultraviolet 320 nm laser excitation for flow cytometry.
Telford, William; Stickland, Lynn; Koschorreck, Marco
2017-04-01
Although multiple lasers and high-dimensional analysis capability are now standard on advanced flow cytometers, ultraviolet (UV) lasers (usually 325-365 nm) remain an uncommon excitation source for cytometry. This is primarily due to their cost, and the small number of applications that require this wavelength. The development of the Brilliant Ultraviolet (BUV fluorochromes, however, has increased the importance of this formerly niche excitation wavelength. Historically, UV excitation was usually provided by water-cooled argon- and krypton-ion lasers. Modern flow cytometers primary rely on diode pumped solid state lasers emitting at 355 nm. While useful for all UV-excited applications, DPSS UV lasers are still large by modern solid state laser standards, and remain very expensive. Smaller and cheaper near UV laser diodes (NUVLDs) emitting at 375 nm make adequate substitutes for 355 nm sources in many situations, but do not work as well with very short wavelength probes like the fluorescent calcium chelator indo-1. In this study, we evaluate a newly available UV 320 nm laser for flow cytometry. While shorter in wavelength that conventional UV lasers, 320 is close to the 325 nm helium-cadmium wavelength used in the past on early benchtop cytometers. A UV 320 nm laser was found to excite almost all Brilliant Ultraviolet dyes to nearly the same level as 355 nm sources. Both 320 nm and 355 nm sources worked equally well for Hoechst and DyeCycle Violet side population analysis of stem cells in mouse hematopoetic tissue. The shorter wavelength UV source also showed excellent excitation of indo-1, a probe that is not compatible with NUVLD 375 nm sources. In summary, a 320 nm laser module made a suitable substitute for conventional 355 nm sources. This laser technology is available in a smaller form factor than current 355 nm units, making it useful for small cytometers with space constraints. © 2017 International Society for Advancement of Cytometry. © 2017 International Society for Advancement of Cytometry.
Corneal tissue welding with infrared laser irradiation after clear corneal incision.
Rasier, Rfat; Ozeren, Mediha; Artunay, Ozgür; Bahçecioğlu, Halil; Seçkin, Ismail; Kalaycoğlu, Hamit; Kurt, Adnan; Sennaroğlu, Alphan; Gülsoy, Murat
2010-09-01
The aim of this study was to investigate the potential of infrared lasers for corneal welding to seal corneal cuts done in an experimental animal model. Full-thickness corneal cuts on freshly enucleated bovine eyes were irradiated with infrared (809-nm diode, 980-nm diode, 1070-nm YLF, and 1980-nm Tm:YAP) lasers to get immediate laser welding. An 809-nm laser was used with the topical application of indocyanine green to enhance the photothermal interaction at the weld site. In total, 60 bovine eyes were used in this study; 40 eyes were used in the first part of the study for the determination of optimal welding parameters (15 eyes were excluded because of macroscopic carbonization, opacification, or corneal shrinkage; 2 eyes were used for control), and 20 eyes were used for further investigation of more promising lasers (YLF and Tm:YAP). Laser wavelength, irradiating power, exposure time, and spot size were the dose parameters, and optimal dose for immediate closure with minimal thermal damage was estimated through histological examination of welded samples. In the first part of the study, results showed that none of the applications was satisfactory. Full-thickness success rates were 28% (2 of 7) for 809-nm and for 980-nm diode lasers and 67% (2 of 3) for 1070-nm YLF and (4 of 6) for 1980-nm Tm:YAP lasers. In the second part of the study, YLF and Tm:YAP lasers were investigated with bigger sample size. Results were not conclusive but promising again. Five corneal incisions were full-thickness welded out of 10 corneas with 1070-nm laser, and 4 corneal incisions were partially welded out of 10 corneas with 1980-nm laser in the second part of the study. Results showed that noteworthy corneal welding could be obtained with 1070-nm YLF laser and 1980-nm Tm:YAP laser wavelengths. Furthermore, in vitro and in vivo studies will shed light on the potential usage of corneal laser welding technique.
Liu, Jukun; Jia, Tianqing; Zhou, Kan; Feng, Donghai; Zhang, Shian; Zhang, Hongxin; Jia, Xin; Sun, Zhenrong; Qiu, Jianrong
2014-12-29
We present a controllable fabrication of nanogratings and nanosquares on the surface of ZnO crystal in water based on femtosecond laser-induced periodic surface structures (LIPSS). The formation of nanogrooves depends on both laser fluence and writing speed. A single groove with width less than 40 nm and double grooves with distance of 150 nm have been produced by manipulating 800 nm femtosecond laser fluence. Nanogratings with period of 150 nm, 300 nm and 1000 nm, and nanosquares with dimensions of 150 × 150 nm2 were fabricated by using this direct femtosecond laser writing technique.
Noh, Tai Kyung; Chung, Bo Young; Yeo, Un Cheol; Chang, SeoYoun; Lee, Mi Woo; Chang, Sung Eun
2015-12-01
Q-switched (QS) 532-nm lasers are widely used to treat solar lentigines. To compare the efficacy and safety of 660-nm and 532-nm QS neodymium-doped yttrium aluminum garnet (Nd:YAG) lasers in the treatment for lentigines in Asians. The halves of each face (randomly chosen) of 8 Korean Fitzpatrick Skin Type III-IV women with facial solar lentigines were treated with either 660-nm or 532-nm lasers. Pigmentation was measured objectively using a profilometric skin analysis tool and subjectively using the pigmentation area and severity index (PSI) score, global assessment of the aesthetic improvement scale (GAIS), and a patient satisfaction score at Weeks 4 and 8. Seven patients completed the study. No significant differences were found in the PSI, GAIS, patient satisfaction score, and melanin average score between the lasers. The melanin average level was significantly reduced by the 660-nm laser but not the 532-nm laser at Week 8 compared with the baseline. Both 660-nm and 532-nm QS Nd:YAG lasers effectively reduce pigmentation for up to 8 weeks with high patient satisfaction. The new 660-nm laser therefore increases the treatment options for lentigines in Asian skin.
Widely tunable short-infrared thulium and holmium doped fluorozirconate waveguide chip lasers.
Lancaster, D G; Gross, S; Withford, M J; Monro, T M
2014-10-20
We report widely tunable (≈ 260 nm) Tm(3+) and Ho(3+) doped fluorozirconate (ZBLAN) glass waveguide extended cavity lasers with close to diffraction limited beam quality (M(2) ≈ 1.3). The waveguides are based on ultrafast laser inscribed depressed claddings. A Ti:sapphire laser pumped Tm(3+)-doped chip laser continuously tunes from 1725 nm to 1975 nm, and a Tm(3+)-sensitized Tm(3+):Ho(3+) chip laser displays tuning across both ions evidenced by a red enhanced tuning range of 1810 to 2053 nm. We also demonstrate a compact 790 nm diode laser pumped Tm(3+)-doped chip laser which tunes from 1750 nm to 1998 nm at a 14% incident slope efficiency, and a beam quality of M(2) ≈ 1.2 for a large mode-area waveguide with 70 µm core diameter.
Gün, Teoman; Metz, Philip; Huber, Günter
2011-03-15
We report efficient cw laser operation of laser diode pumped Pr(3+)-doped LiYF4 crystals in the visible spectral region. Using two InGaN laser diodes emitting at λ(P)=443.9 nm with maximum output power of 1 W each and a 2.9-mm-long crystal with a doping concentration of 0.5%, output powers of 938 mW, 418 mW, 384 mW, and 773 mW were achieved for the laser wavelengths 639.5 nm, 607.2 nm, 545.9 nm, and 522.6 nm, respectively. The maximum absorbed pump powers were approximately 1.5 W, resulting in slope efficiencies of 63.6%, 32.0%, 52.1%, and 61.5%, as well as electro-optical efficiencies of 9.4%, 4.2%, 3.8%, and 7.7%, respectively. Within these experiments, laser diode-pumped laser action at 545.9 nm was demonstrated for what is believed to be the first time.
[Comparative investigation of underwater-LIBS using 532 and 1 064 nm lasers].
Song, Jiao-Jian; Tian, Ye; Lu, Yuan; Li, Ying; Zheng, Rong-Er
2014-11-01
With the hope of applying laser induced breakdown spectroscopy (LIBS) to the ocean applications, the laser energy at 532 and 1 064 nm wavelength with 3 and 40 mj respectively was used, which was near their breakdown threshold. Extensive experimental investigations of LIBS from CaCl2 water solution were carried out in this paper using different laser wavelengths of 532 and 1 064 nm. The obtained results show that compared with the 532 nm laser, the 1 064 nm laser can induce the plasma in water with higher emission intensity and longer lifetime, while the reproducibility of LIBS signal under 1 064 nm laser is poorer. On the other hand, due to the different attenuation ratios of 532 and 1 064 nm laser energies in water, the LIBS signal of 1 064 nm laser decreases a lot within the transmission distance range 2-5 cm, while LIBS signal of 532 nm remains the same, because that the wavelength of 532 nm lies in the "transmission window" of the water solution. This study will provide valuable design considerations for the development of LIBS-sea system in near future.
High-efficiency high-brightness diode lasers at 1470 nm/1550 nm for medical and defense applications
NASA Astrophysics Data System (ADS)
Gallup, Kendra; Ungar, Jeff; Vaissie, Laurent; Lammert, Rob; Hu, Wentao
2012-03-01
Diode lasers in the 1400 nm to 1600 nm regime are used in a variety of applications including pumping Er:YAG lasers, range finding, materials processing, aesthetic medical treatments and surgery. In addition to the compact size, efficiency, and low cost advantages of traditional diode lasers, high power semiconductor lasers in the eye-safe regime are becoming widely used in an effort to minimize the unintended impact of potentially hazardous scattered optical radiation from the laser source, the optical delivery system, or the target itself. In this article we describe the performance of high efficiency high brightness InP laser bars at 1470nm and 1550nm developed at QPC Lasers for applications ranging from surgery to rangefinding.
Detection of Vegetable Oil Variance Using Surface Plasmon Resonance (SPR) Technique
NASA Astrophysics Data System (ADS)
Supardianningsih; Panggabean, R. D.; Romadhon, I. A.; Laksono, F. D.; Nofianti, U.; Abraha, K.
2018-05-01
The difference between coconut oil, corn oil, olive oil, and palm oil has been detected using surface plasmon resonance (SPR) technique. This is a new method in material characterization that can be used to identify vegetable oil variance. The SPR curve was measured by SPR system consisting of optical instruments, mechanical instruments, Main UNIT, and user interface (computer). He-Ne laser beam of wavelength 633 nm was used as light source, while gold (Au) thin film evaporated on half cylinder prism was used as the base so that surface plasmon polariton (SPP) waves propagate at the interface. Tween-80 and PEG-400 are used as surfactant and co-surfactant to make water-oil emulsion from each sample. The sample was prepared with the ratio of oil: surfactant: co-surfactant as 1:2:1 and then stirred on the water to make emulsions. The angle shift was measured by the change of SPR angle from prism/Au/air system to prism/Au/water-oil emulsion. The different SPR angle of each sample has been detected in the various number of spray, a method that was used for depositing the emulsion. From this work, we conclude that the saturated fatty acid component was the most significant component that changes the refractive index in the vegetable oil in water emulsion that can be used to characterize the vegetable oil variance.
NASA Astrophysics Data System (ADS)
Min, Young-Hoon; Kim, Yong-Kweon
1998-09-01
A silicon based micro mirror array is a highly efficient component for use in optical applications as adaptive optical systems and optical correlators. Many types of micro mirror or micro mirror array have been studied and proposed in order to obtain the optimal performance according to their own purposes. A micro mirror array designed, fabricated and tested in this paper consists of 5 X 5 single layer polysilicon-based, electrostatically driven actuators. The micro mirror array for the optical phase modulation is made by using only two masks and can be driven independently by 25 channel circuits. About 6 (pi) phase modulation is obtained in He-Ne laser ((lambda) equals 633 nm) with 67% fill-factor. In this paper, the deflection characteristics of the actuators in controllable range were studied. The experimental results show that the deflection characteristics is much dependent upon a residual stress in flexure, the initial curvature of mirror due to stress gradient and an electrostatic force acted on other element except for mirror itself. The modeling results agree well with the experimental results. Also, it is important to fabricate a flat mirror that is not initially curved because the curved mirror brings a bad performance in optical use. Therefore, a new method to obtain the flat mirror by using the gold metallization in spite of the residual stress unbalance is proposed in this paper.
Future tense: call for a new generation of artists
NASA Astrophysics Data System (ADS)
Ohlmann, Dietmar
1995-02-01
Some people try hard to educate others about the beauty and technical benefits of holographic applications but another generation is already waiting to learn more about the media which talk to them about the future. Today the most common question is 'How can I do holograms with a computer?' 'Can I do it with an Amiga?' For the MIT specialists these are now very simple questions. We can expect to see the present shape of the holographic laboratory pass into history. I personally like to work with a VHS camera and mix it with CAD/CAM images, but computer and video are not the only media which will change the face of holography. The He.Ne. will be exchanged by diode laser. In a wavelength of 690 nm, some of them bring 40 mW in single mode and single line, not bigger than your little finger. Having such energy in so little a container, and the state of the art drifts rapidly into more flexibility. Using new media and introducing it in our societies give us a new responsibility. Would too much media kill the art? I do not think so, because I like the variety of media which give new possibility of expression. The game with new media is the power of creativity and it will find its meaning by itself.
NASA Astrophysics Data System (ADS)
Sathya, K.; Dhamodharan, P.; Dhandapani, M.
2018-05-01
A new proton transfer complex was synthesized by the reaction between 2-amino-3-methyl pyridine with 3,5-dinitro benzoic acid in methanol solvent at room temperature. Chemical composition and stoichiometry of the synthesized complex 2-amino-3-methylpyridinium 3,5-dinitrobenzoate (AMPDB) were verified by CHN analysis. The AMPDB crystals were subjected to FT-IR spectral analysis to confirm the functional groups in the compound. UV-Vis-NIR spectral studies revealed that the AMPDB has a large optical transparency window. Single crystal XRD analysis reveals that AMPDB belongs to a monoclinic system with P21/c space group. NMR spectroscopic data indicate the exact carbon skeleton and hydrogen environment in the molecular structure of AMPDB. The thermal stability of the compound was investigated by thermogravimetry (TG). Computational studies such as optimisation of molecular geometry, natural bond analysis (NBO), Mulliken population analysis and HOMO-LUMO analysis were performed using Gaussian 09 software by B3LYP method at 6-311 G(d p) basis set. The first order hyperpolarizability (β) value is 37 times greater than that of urea. The optical nonlinearities of AMPDB have been investigated by Z-scan technique with He-Ne laser radiation of wavelength 632.8 nm. Hirshfeld analysis indicate O⋯H/H⋯O interactions are the superior interactions confirming intensive hydrogen bond net work.
Effects of pre-radiation exposure to LLLT of normal and malignant cells.
Barasch, Andrei; Raber-Durlacher, Judith; Epstein, Joel B; Carroll, James
2016-06-01
Low-level laser therapy (LLLT) efficacy for the prevention of cancer treatment-induced oral mucositis (OM) has been amply described. However, potential protection of malignant cells remains a legitimate concern for clinicians. We tested LLLT-induced protection from ionizing radiation killing in both malignant and normal cells. We treated six groups each of normal human lymphoblasts (TK6) and human leukemia cells (HL60) with He-Ne LLLT (632.8 nm, 35 mW, CW, 1 cm(2), 35 mW/cm(2) for 3-343 s, 0.1-12 J/cm(2)) prior to exposure to ionizing radiation (IR). Cells were then incubated and counted daily to determine their survival. Optimization of IR dose and incubation time was established prior to testing the effect of LLLT. Growth curves for both cell lines showed significant declines after exposure to 50-200 cGy IR when compared to controls. Pre-radiation exposure to LLLT (4.0 J/cm(2)) followed by 1-h incubation blocked this decline in TK6 but not in HL60 cells. The latter cells were sensitized to the killing effects of IR in a dose-dependent manner. This study shows that pre-IR LLLT treatment results in a differential response of normal vs. malignant cells, suggesting that LLLT does not confer protection and may even sensitize cancer cells to IR killing.
Grate, Jay W; Warner, Marvin G; Ozanich, Richard M; Miller, Keith D; Colburn, Heather A; Dockendorff, Brian; Antolick, Kathryn C; Anheier, Norman C; Lind, Michael A; Lou, Jianlong; Marks, James D; Bruckner-Lea, Cynthia J
2009-05-01
A renewable surface biosensor for rapid detection of botulinum neurotoxin serotype A is described based on fluidic automation of a fluorescence sandwich immunoassay, using a recombinant protein fragment of the toxin heavy chain ( approximately 50 kDa) as a structurally valid simulant. Monoclonal antibodies AR4 and RAZ1 bind to separate non-overlapping epitopes of the full botulinum holotoxin ( approximately 150 kDa). Both of the targeted epitopes are located on the recombinant fragment. The AR4 antibody was covalently bound to Sepharose beads and used as the capture antibody. A rotating rod flow cell was used to capture these beads delivered as a suspension by a sequential injection flow system, creating a 3.6 microL column. After perfusing the bead column with sample and washing away the matrix, the column was perfused with Alexa 647 dye-labeled RAZ1 antibody as the reporter. Optical fibers coupled to the rotating rod flow cell at a 90 degrees angle to one another delivered excitation light from a HeNe laser (633 nm) using one fiber and collected fluorescent emission light for detection with the other. After each measurement, the used Sepharose beads are released and replaced with fresh beads. In a rapid screening approach to sample analysis, the toxin simulant was detected to concentrations of 10 pM in less than 20 minutes using this system.
Comparison of 980-nm and 1070-nm in endovenous laser treatment (EVLT)
NASA Astrophysics Data System (ADS)
Topaloglu, Nermin; Tabakoglu, Ozgur; Ergenoglu, Mehmet U.; Gülsoy, Murat
2009-07-01
The use of endovenous laser treatment for varicose veins has been increasing in recent years. It is a safer technique than surgical vein stripping. Its complications (e.g. bruising, pain) are less than the complications of surgical vein stripping. But best parameters such as optimum wavelength, power, and application duration are still under investigation to clarify uncertainties about this technique. To prevent its complications and improve its clinical outcomes, the exact mechanism of it has to be known. The aim of this study is to investigate the effect of different laser wavelengths on endovenous laser therapy. In this study 980-nm diode laser and 1070-nm fiber laser were used. Human veins were irradiated with 980-nm and 1070-nm lasers at 8 W and 10 W to find the optimal power and wavelength. After laser application, remarkable shrinkage was observed. Inner and outer diameters of the veins also narrowed for both of the laser types. 10 W of 980-nm laser application led to better shrinkage results.
Investigations of large area electron beam diodes for excimer lasers. Final report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1993-12-31
This report summarizes the results of a one year research program at the University of Michigan to investigate the physics and technology of microsecond electron beam diodes. These experiments were performed on the Michigan Electron Long Beam Accelerator (MELBA) at parameters: Voltage {equals} {minus}0.65 to {minus}0.9 MV, current {equals} 1 {minus}50 kA, and pulselength {equals} 0.5 {minus} 5 microseconds. Major accomplishments include: (1) the first two-wavelength (CO2 and HeNe) laser deflection measurements of diode plasma and neutrals; (2) measurements of the effects on magnetic field gradient on microsecond diode closure; (3) demonstration of good fidelity of processed x-ray signals asmore » a diagnostic of beam voltage; (4) extended-pulselength scaling of electron beam diode arcing and diode closure; and (5) innovative Cerenkov plate diagnostics of e-beam dynamics.« less
The construction and characterization of optical traps for manipulating microscopic particles
NASA Astrophysics Data System (ADS)
Thompson, Tiffany; Behringer, Ernest
2011-04-01
Optical traps use tightly focused laser light to manipulate microscopic particles and have applications in nanofabrication, characterizing DNA, and in vitro fertilization [1]. We will describe the design, construction, and characterization of an optical trap that is capable of trapping and imaging 3 μm polystyrene spheres using a 12 mW HeNe laser. The design was based on previous work [2,3] describing how to build affordable optical traps. We will discuss trapping forces and their calibration. [4pt] [1] D.G. Grier, "A Revolution in Optical Manipulation," Nature 424, 810-816 (2003). [0pt] [2] S.P. Smith et al., "Inexpensive optical tweezers for undergraduate laboratories," Am. J. Phys. 67 (1), 26-35 (1999).[0pt] [3] J. Bechhoefer et al., "Faster, cheaper, safer optical tweezers for the undergraduate laboratory," Am. J. Phys. 70 (4), 393-400 (2001).
Thermophysical Property Measurements of Molten Slag and Welding Flux by Aerodynamic Levitator
NASA Astrophysics Data System (ADS)
Onodera, Kenta; Nakamura, Airi; Hakamada, Shinya; Watanabe, Masahito; Kargl, Florian
Molten slag and welding flux are important materials for steel processing. Due to lack of durable refractory materials, there is limited publication data on the thermophysical properties of these slags. Therefore, in this study, we measured density and viscosity of CaO-Al2O3-SiO2 slag and welding flux using Aerodynamic Levitation (ADL) with CO2-laser heating in which can be achieve containerless and non-contacting conditions for measurements. For density measurements, in order to obtain correct shape of the droplet we used high-speed camera with the extended He-Ne laser to project the shadow image without the influence of the selfluminescence at the high temperature. For viscosity measurement, we also have a unique vibration method; it caused oscillation in a sample by letting gas for levitation vibrate by an acoustic speaker. Using these techniques, we succeeded to measure systematically density and viscosity of molten oxides system.
Characterization of a Structural Transformation of Carbon Nanotube Materials by Raman Spectroscopy
NASA Technical Reports Server (NTRS)
Cui, Y.; Burger, A.; Zhu, S.; Su, C.-H.; Lehoczky, S. L.; Whitaker, Ann F. (Technical Monitor)
2001-01-01
Raman spectra of carbon nanotubes and carbon microstructure materials synthesized on Si substrates by pulsed laser vaporization have been measured in the range of 50/cm to 4500/cm with the excitation of He-Ne laser. It is found that the formation of nanotubes depends strongly on the growth temperatures and high quality multi-wall and single-wall nanotubes were produced at 700 and 990 C, respectively. The Raman spectra of one sample grown at 700 C were found to be dependent on the excitation intensity. The spectra of the sample suggest that the structure is similar to that of multi-wall nanotubes at low excitation intensity (2.5 kW/sq cm) and it converts to the structure of single-wall nanotubes at higher intensity (25 kW/sq cm). Measurements taken while cycling the light intensity indicate a reversible structural transition.
Aerodyne Research mobile infrared methane monitor
NASA Technical Reports Server (NTRS)
Mcmanus, J. B.; Kebabian, P. L.; Kolb, C. E.
1991-01-01
An improved real-time methane monitor based on infrared absorption of the 3.39 micron line of a HeNe laser is described. Real time in situ measurement of methane has important applications in stratospheric and tropospheric chemistry, especially when high accuracy measurements can be made rapidly, providing fine spatial-scale information. The methane instrument provides 5 ppb resolution in a 1 sec averaging time. A key feature in this instrument is the use of magnetic (Zeeman) broadening to achieve continuous tunability with constant output power over a range of 0.017/cm. The instruments optical absorption path length is 47 m through sampled air held at 50 torr in a multipass cell of the Herriott (off-axis resonator) type. A microprocessor controls laser frequency and amplitude and collects data with minimal operator attention. The instrument recently has been used to measure methane emissions from a variety of natural and artificial terrestrial sources.
Lidar Measurements of the Stratosphere and Mesosphere at the Biejing Observatory
NASA Astrophysics Data System (ADS)
Du, Lifang; Yang, Guotao; Cheng, Xuewu; Wang, Jihong
With the high precision and high spatial and temporal resolution, the lidar has become a powerful weapon of near space environment monitoring. This paper describes the development of the solid-state 532nm and 589nm laser radar, which were used to detect the wind field of Beijing stratosphere and mesopause field. The injection seeding technique and atomic absorption saturation bubble frequency stabilization method was used to obtain narrow linewidth of 532nm lidar, Wherein the laser pulse energy of 800mJ, repetition rate of 30Hz. The 589nm yellow laser achieved by extra-cavity sum-frequency mixing 1064nm and 1319nm pulse laser with KTP crystal. The base frequency of 1064nm and 1319nm laser adopted injection seeding technique and YAG laser amplification for high energy pulse laser. Ultimately, the laser pulse of 150mJ and the linewidth of 130MHz of 589nm laser was obtain. And after AOM crystal frequency shift, Doppler frequency discriminator free methods achieved of the measuring of high-altitude wind. Both of 532nm and 589nm lidar system for engineering design of solid-state lidar provides a basis, and also provide a solid foundation for the development of all-solid-state wind lidar.
Laser-diode-pumped 1319-nm monolithic non-planar ring single-frequency laser
NASA Astrophysics Data System (ADS)
Wang, Qing; Gao, Chunqing; Zhao, Yan; Yang, Suhui; Wei, Guanghui; 2, Dongmei Hong
2003-10-01
Single-frequency 1319-nm laser was obtained by using a laser-diode-pumped monolithic Nd:YAG crystal with a non-planar ring oscillator (NPRO). When the NPRO laser was pumped by an 800-?m fiber coupled laser diode, the output power of the single-frequency 1319-nm laser was 220 mW, and the slope efficiency was 16%. With a 100-1m fiber coupled diode laser pumped, 99-mW single-frequency 1319-nm laser was obtained with a slope efficiency of 29%.
Kinnunen, Matti; Kauppila, Antti; Karmenyan, Artashes; Myllylä, Risto
2011-09-15
Optical tweezers can be used to manipulate small objects and cells. A trap can be used to fix the position of a particle during light scattering measurements. The places of two separately trapped particles can also be changed. In this Letter we present elastic light scattering measurements as a function of scattering angle when two trapped spheres are illuminated with a He-Ne laser. This setup is suitable for trapping noncharged homogeneous spheres. We also demonstrate measurement of light scattering patterns from two separately trapped red blood cells. Two different illumination schemes are used for both samples.
Laser biostimulation of articular cartilage: in vitro evaluation
NASA Astrophysics Data System (ADS)
Jia, Yali; Guo, Zhouyi; Yang, Xiaohong; Zeng, Chang-Chun
2004-07-01
In the orthopaedic field, the repair of ariticular cartilage is still a difficult problem, because of the physiological characters of cartilaginous tissues and chondrocytes. To find an effective method of stimulating their regeneration, this in vitro study focuses on the biostimulation of rabbit articular chondrocytes by low-power He-Ne laser. The articular chondrocytes isolated from the cartilage of the medial condyle of the femur of the rabbit were incubated in HamF12 medium. The second passage culture were spread on 24 petri dishes and were irradiated with laser at power density of 2 - 12 mW/cm2 for 6.5 minutes, corresponding to the energy density of 1-6 J/cm2. Laser treatment was performed three times at a 24-hour interval. After lasering, incubation was continued for 24 hours. Non-irradiated cells were kept under the same conditions as the irradiated ones. The cell proliferation activity was evaluated with a XTT colorimetric method. Irradiation of 4 - 6 J/cm2 revealed a considerably higher cell proliferation activity comparing to control cultures. Thereinto, the energy density of 4 and 5 J/cm2 remarkably increased cell growth (P<0.01). The present study showed that a particular laser irradiation stimulates articular chondrocytes proliferation. These findings might be clinically relevant, indicating that low-power laser irradiation treatment is likely to achieve the repair of articular cartilage in clinic.
Orange fiber laser for ophthalmology
NASA Astrophysics Data System (ADS)
Adachi, M.; Kojima, K.; Hayashi, K.
2007-02-01
For the light source of photocoagulators for ophthalmology, orange laser is more suitable than green laser because of low scattering loss by the crystalline lens, and low absorption by xanthophylls in the retina. We developed two orange fiber lasers (580 nm and 590 nm) to investigate the effect depending on the difference in the range of orange. The 580nm laser is composed of a 1160 nm fiber laser and a Periodically Polled Lithium Niobate (PPLN) crystal for second harmonic generation. The 1160 nm fiber laser beam is focused into the MgO-doped PPLN crystal whose length is 30 mm with 3-pass configuration. Continuous-wave 1.3 W output power of 580 nm was obtained with 5.8 W input power of 1160nm for the first time. The conversion efficiency was 22%. The band width of the second harmonic was 0.006 nm (FWHM). The 590 nm laser is almost the same as 580 nm laser source. In this case we used a Raman shift fiber to generate 1180 nm, and the output power of 590 nm was 1.4 W. We developed an evaluation model of photocoagulator system using these two laser sources. A 700 mW coagulation output power was obtained with this orange fiber laser photocoagulator system. This is enough power for the eye surgery. We have the prospect of the maintenance-free, long-life system that is completely air-cooled. We are planning to evaluate this photocoagulator system in order to investigate the difference between the two wavelengths at the field test.
Gruen, Dieter M.
2000-01-01
A 213 nm laser beam is capable of single photon ablative photodecomposition for the removal of a polymer or biological material substrate. Breaking the molecular bonds and displacing the molecules away from the substrate in a very short time period results in most of the laser photon energy being carried away by the displaced molecules, thus minimizing thermal damage to the substrate. The incident laser beam may be unfocussed and is preferably produced by quintupling the 1064 nm radiation from a Nd:YAG solid state laser, i.e., at 213 nm. In one application, the 213 nm laser beam is expanded in cross section and directed through a plurality of small beta barium borate (BBO) crystals for increasing the energy per photon of the laser radiation directed onto the substrate. The BBO crystals are arranged in a crystal matrix array to provide a large laser beam transmission area capable of accommodating high energy laser radiation without damaging the BBO crystals. The BBO crystal matrix array may also be used with 266 nm laser radiation for carrying out single or multi photon ablative photodecomposition. The BBO crystal matrix array may also be used in an optical parametric oscillator mode to generate high power tunable laser radiation in the range of 210-400 nm.
Barikbin, Behrooz; Khodamrdi, Zeinab; Kholoosi, Leila; Akhgri, Mohammad Reza; Haj Abbasi, Majid; Hajabbasi, Mojgan; Razzaghi, Zahra; Akbarpour, Samaneh
2017-05-17
This study aimed to evaluate the effectiveness of a combined set of low level diode laser scanner (665 nm and 808nm) on hair growth, and assessment of safety and effectiveness of a new laser scanner on hair growth treatment procedure in androgenic alopecia. 90 patients (18 to 70 years) with androgenic alopecia were randomized into three groups. The first group (n=30) received 655 nm red light using laser hat, the second group (n=30) received 655 nm red laser plus 808 nm infrared laser using a laser scanner of hair growth device (with the patent number: 77733) and the third group (n=30) received no laser as the control group. Patients in laser scanner group had better results and showed a higher increase in terminal hair density compared with laser hat group (mean of 9.61 versus 9.16 per cm 2 ). We found significant decrease in terminal hair density from baseline in control group (mean -1.8 per cm 2 , p<0.0001). Results showed a statistically significant improvement in the laser scanner of the hair growth group compared with laser hat and the control group. The study showed that treatment with new laser devise had a promising result without any observable adverse effects.
NASA Astrophysics Data System (ADS)
Shi, Tiantian; Pan, Duo; Chang, Pengyuan; Shang, Haosen; Chen, Jingbiao
2018-04-01
Without exploiting any frequency selective elements, we have realized a highly integrated, single-mode, narrow-linewidth Nd:YAG 1064 nm laser, which is end-pumped by the 808.6 nm diode laser in an integrated invar cavity. It turns out that each 1064 nm laser achieves a most probable linewidth of 8.5 kHz by beating between two identical laser systems. The output power of the 1064 nm laser increases steadily as the 808.6 nm pump power is raised, which can be up to 350 mW. Moreover, the resonant wavelength of cavity grows continuously in a certain crystal temperature range. Such a 1064 nm laser will be frequency stabilized to an ultrastable cavity by using the Pound-Drever-Hall technique and used as the good cavity laser to lock the main cavity length of 1064/1470 nm good-bad cavity dual-wavelength active optical clock.
Effect of low-power He-Ne ILIB on rheology in patients with cerebral infarction
NASA Astrophysics Data System (ADS)
Lu, Zheng-Guo
1998-11-01
We determined rheology in patients with cerebral infarction, before and after low-power He-Ne ILIB. The test covered whole blood viscosity red blood cell distortion index, platelet aggregation and D-dimer. The results shoed that low-power He-Ne ILIB results in non-significant decrease in whole blood viscosity, significant decrease in plasma viscosity, platelet aggregation and D-dimer and significant increase in RBC rheology index. This study suggests that He- He ILIB which may improve rheology and clinical symptoms of cerebral infarction patients is a simple, safe and effective therapy.
Blood absorption during 970 and 1470 nm laser radiation in vitro.
Shaydakov, E; Ilyukhin, E; Rosukhovskiy, D
2015-10-01
Soon after introduction of water lasers in medical practice for EVLA, less power and energy line density have been used. However, there are no experimental grounds for different energy modes and there is no clear evidence for a difference in the effect of the two wavelengths dealt with in this study. The goal of this study was to evaluate the temperature profile of various laser action modes with testing devices. Three experimental testing devices consisted of cylinders filled with whole donor blood and a set of temperature sensors installed in different positions. We have determined the range of temperatures around the fiber tip of 970 and 1470 nm lasers. The average temperature of 970 nm laser at 1 mm distance along the axis from the fiber tip substantially differed from that of 1470 nm laser, power being equal. Statistically substantial differences were found in endovenous laser ablation simulation in vitro for the 970 nm and 1470 nm laser radiation. Similar temperatures can be reached with 970 nm lasers if power is increased.
Wezel, Felix; Wendt-Nordahl, Gunnar; Huck, Nina; Bach, Thorsten; Weiss, Christel; Michel, Maurice Stephan; Häcker, Axel
2010-04-01
Several diode laser systems were introduced in recent years for the minimal-invasive surgical therapy of benign prostate enlargement. We investigated the ablation capacities, hemostatic properties and extend of tissue necrosis of different diode lasers at wavelengths of 980, 1,318 and 1,470 nm and compared the results to the 120 W GreenLight HPS laser. The laser devices were evaluated in an ex vivo model using isolated porcine kidneys. The weight difference of the porcine kidneys after 10 min of laser vaporization defined the amount of ablated tissue. Blood loss was measured in blood-perfused kidneys following laser vaporization. Histological examination was performed to assess the tissue effects. The side-firing 980 and 1,470 nm diode lasers displayed similar ablative capacities compared to the GreenLight HPS laser (n.s.). The 1,318-nm laser, equipped with a bare-ended fiber, reached a higher ablation rate compared to the other laser devices (each P < 0.05). A calculated 'output power efficiency per watt' revealed that the 1,318-nm laser with a bare-ended fiber reached the highest rate compared to the side-firing devices (each P < 0.0001). All three diode lasers showed superior hemostatic properties compared to the GreenLight HPS laser (each P < 0.01). The extend of morphological tissue necrosis was 4.62 mm (1,318 nm), 1.30 mm (1,470 nm), 4.18 mm (980 nm) and 0.84 mm (GreenLight HPS laser), respectively. The diode lasers offered similar ablative capacities and improved hemostatic properties compared to the 120 W GreenLight HPS laser in this experimental ex vivo setting. The higher tissue penetration of the diode lasers compared to the GreenLight HPS laser may explain improved hemostasis.
2017-08-01
accessories for mounting e. Laser power supply f. TEC power supply 12. Optical filters from SEMROCK ®, THORLABS Inc., EDMUND OPTICS® a. 532-nm, laser...line filter ( SEMROCK ®) b. 550-nm, hard-coated, short-pass filter (THORLABS Inc.) c. 532-nm long-pass filter ( SEMROCK ®) d. 808-nm laser-line filter... SEMROCK ®) e. 850-nm /10-nm full width at half maximum (FWHM) bandpass filter ( SEMROCK ®) f. 980-nm bandpass filter ( SEMROCK ®) g. 976-nm laser-line
Vibrational Spectroscopy of Laser Cooled CaH
2015-10-28
about 1 mW 369 nm laser with a bandpass filter ( Semrock 395/20 nm) that reflects the 21 399 nm laser and transmits the 369 nm laser, which are sent along...and the back mirror is a flat broadband 67 ( Semrock MaxMirror) mirror that has over 99% reflectivity over a wide range as shown in Fig. 28. The lasers
A 15 W 1152 nm Raman fiber laser with 6 nm spectral width for Ho3+-doped crystal's pumping source
NASA Astrophysics Data System (ADS)
Chen, Xiuyan; Jiang, Huawei
2016-12-01
A 11.5 W 1152 nm Raman fiber laser with 6 nm spectral width was demonstrated based on the resonator constructed with one fiber loop mirror and one fiber Bragg grating. By mans of experimental measurement and theoretical calculation, the reflectivity of the fiber loop mirror was confirmed as 0.93. The Yb3+-doped 1090 nm fiber length was about 5 m. When the maximum pumping power of 976 nm laser was 54.8 W, 32.2 W 1090 nm laser was obtained and the optical to optical conversion efficiency from 1090 nm to 1152 nm light was 48%. Finally, the 1152 nm Raman fiber laser was used for pumping Ho3+:LLF crystal, and the 1194 nm fluorescence emission peak was detected for the first time.
40nm tunable multi-wavelength fiber laser
NASA Astrophysics Data System (ADS)
Jia, Qingsong; Wang, Tianshu; Zhang, Peng; Dong, Keyan; Jiang, Huilin
2014-12-01
A Brillouin-Erbium multi-wavelength tunable fiber laser at C-band is demostrated. A 10 km long singlemode fiber(SMF), a 6 m long Erbium-doped fiber, two couplers, a wavelength division multiplexer, a isolator, an optical circulator, a 980nm pump laser and a narrow linewidth tunable laser are included in the structure. A segment of 10 km-long single-mode fiber (SMF) between the two ports of a 1×2 coupler is used as Brillouin gain. Ebiumdoped fiber amplifier (EDFA) consists of a segment of 6m er-doped fiber pumped by 980nm laser dioder . A narrow linewidth tunable laser from 1527 to 1607 nm as Brillouin bump, At the Brillouin pump power of 8mW and the 980 nm pump power of 400 mw, 16 output channels with 0.08 nm spacing and tuning range of 40 nm from 1527 nm to 1567 nm are achieved. We realize the tunable output of wavelength by adjusting the 980 nm pump power and the Brillouin pump wavelength. Stability of the multiwavelength fiber laser is also observed.
Experimental basis of laser therapy in pharynx pathology
NASA Astrophysics Data System (ADS)
Toropova, Lyudmila A.; Fedyukovich, Lyudmila V.; Egorova, Alla B.
1998-07-01
Membrane-damaging action of laser irradiation comparing with membranotoxic activity of model xenobiotics (Novocain and Acrylamide) has been evaluated in our experiments using Rosette-Forming Ability test (RFA) on rat blood lymphocytes, thymocytes, splenocytes for the assessment of membrane- mediated and receptor-mediated immune cells interactions. Infra-red laser irradiation (80 and 1500 Hz, 0.89 mkM) in vivo induced 2-fold increase of lymphocytes capable to form specific rosettes with xenogenous erythrocytes. T-lymphocytes were greatly sensitive to the laser influence. Acute laser exposure (128 sec) induced changes similar to Novocain action (1/2 LD50). Five-fold increase of the laser exposure time (especially for low frequency regime) resulted in more prominent changes in intercellular communication which were found to be similar to the action of Acrylamide (1/2 LD50). B-lymphocytes and splenocytes have been assumed as target cells for the action of laser with the frequency of 1500 Hz. Course application of IR or He-Ne laser induced decrease of RFA for all immune cells tested, and for blood lymphocytes, respectively. Thus, laser-induced changes in immune cells interaction may be connected with reversible injury of cell surface membrane followed by the dysregulation of cellular communication. Based on experimental data, the optimal regime of IR laserotherapy (0.89 and 0.63 micrometer) was chosen for the treatment of 200 patients with chronic decompensated tonsillitis. Efficiency of laser application was confirmed by cytological analysis of lacunes, laserodopplerofluometria, vegetative nervous system evaluation etc. and was found to be dependent on membranotropic activity of laser irradiation.
A Multicomponent Large Ringlaser for Seismology: First Observations
NASA Astrophysics Data System (ADS)
Igel, H.; Gebauer, A.; Simonelli, A.; Kodet, J.; Bernauer, F.; Donner, S.; Wassermann, J. M.; Tanimoto, T.; Schreiber, K. U.
2017-12-01
During 2016 a large 4-component ring laser structure called "Romy" was built and implemented underground in the Geophysical Observatory of the Ludwig-Maximilians-University (LMU) 20km outside Munich primarily funded by the European Research Council and LMU. The ring laser has a tetrahedral top-down shape with four triangles of 12m side length. The independent triangular He-Ne ring lasers with 12 m side length are expected to resolve rotational motions down to 12 prad/s/sqrt(Hz), allowing us to record below the assumed low-noise model for rotational ground motions in a wide frequency band (e.g., ocean-generated noise, free oscillations, local regional and global earthquakes). Recently, Romy was described in a feature article in Science (Hand, DOI: 10.1126/science.aal1069). We will present the current state of the instrument and discuss the operation principle and quality of the ring laser components. First observations include the ocean-generated noise, the late 2016 earthquake sequence of Italy, and several teleseismic events. We compare ring laser observations from different sites (Gran Sasso Underground Laboratory, Italy, and G-ring Wettzell, Germany) in relation with their local site conditions. We report on future plans to stabilize the ring geometry providing long-term stability for geodetic applications such as the precise measurement of the Earth's complete rotation vector.
Coherent and noncoherent low-power diodes in clinical practice
NASA Astrophysics Data System (ADS)
Antipa, Ciprian; Pascu, Mihail-Lucian; Stanciulescu, Viorica; Vlaiculescu, Mihaela; Ionescu, Elena; Bordea, Daniel
1997-05-01
Clinical efficacy of the low power laser (LPL) in medical treatments is still not well established. In a double blind, placebo controlled study, we tried to find out first which type of LPL is more efficient, and second if coherence is an important character for clinical efficacy. We treated 1228 patients having different rheumatic diseases, with low power diode, used as follows: A group: IR coherent diode, continuous emission, 3 mW power; B group: IR coherent diode, pulsed emission, output power about 3 mW; C group: IR noncoherent diode continuous emission 9 mW power; D group: both IR diode lasers (continuous or pulsed) and HeNe laser, continuous emission, 2 mW power; E group: placebo laser as control group. The energy dose used for every group was the same, as well as the clinical protocols. The positive results were: 66.16% for A group; 64.06% for B group; 48.87% for C group; 76.66% for D group, and 39.07% for E group. Finally, we showed that LPL is really efficient in the treatment of some rheumatic diseases, especially when red and IR diode laser were used in combination. The type of emission (continuous or pulsed) is not important, but coherence is obviously necessary for clinical efficacy.
Saydjari, Yves; Kuypers, Thorsten; Gutknecht, Norbert
2016-01-01
Objective. In endodontics, Nd:YAG laser (1064 nm) and diode laser (810 nm and 980 nm) devices are used to remove bacteria in infected teeth. A literature review was elaborated to compare and evaluate the advantages and disadvantages of using these lasers. Methods. Using combined search terms, eligible articles were retrieved from PubMed and printed journals. The initial search yielded 40 titles and 27 articles were assigned to full-text analysis. The studies were classified based upon laser source, laser energy level, duration/similarity of application, and initial and final bacterial count at a minimum of 20 prepared root canals. Part of the analysis was only reduced microorganisms and mechanically treated root canals upon preparation size of ISO 30. All studies were compared to evaluate the most favorable laser device for best results in endodontic therapy. Results. A total of 22 eligible studies were found regarding Nd:YAG laser 1064 nm. Four studies fulfilled all demanded criteria. Seven studies referring to the diode laser 980 nm were examined, although only one fulfilled all criteria. Eleven studies were found regarding the diode laser 810 nm, although only one study fulfilled all necessary criteria. Conclusions. Laser therapy is effective in endodontics, although a comparison of efficiency between the laser devices is not possible at present due to different study designs, materials, and equipment.
Tian, Lan; Wang, Jingxuan; Wei, Ying; Lu, Jianren; Xu, Anting; Xia, Ming
2017-02-01
Research on auditory neural triggering by optical stimulus has been developed as an emerging technique to elicit the auditory neural response, which may provide an alternative method to the cochlear implants. However, most previous studies have been focused on using longer-wavelength near-infrared (>1800 nm) laser. The effect comparison of different laser wavelengths in short-wavelength infrared (SWIR) range on the auditory neural stimulation has not been previously explored. In this study, the pulsed 980- and 810-nm SWIR lasers were applied as optical stimuli to irradiate the auditory neurons in the cochlea of five deafened guinea pigs and the neural response under the two laser wavelengths was compared by recording the evoked optical auditory brainstem responses (OABRs). In addition, the effect of radiant exposure, laser pulse width, and threshold with the two laser wavelengths was further investigated and compared. The one-way analysis of variance (ANOVA) was used to analyze those data. Results showed that the OABR amplitude with the 980-nm laser is higher than the amplitude with the 810-nm laser under the same radiant exposure from 10 to 102 mJ/cm 2 . And the laser stimulation of 980 nm wavelength has lower threshold radiant exposure than the 810 nm wavelength at varied pulse duration in 20-500 μs range. Moreover, the 810-nm laser has a wider optimized pulse duration range than the 980-nm laser for the auditory neural stimulation.
Kuypers, Thorsten; Gutknecht, Norbert
2016-01-01
Objective. In endodontics, Nd:YAG laser (1064 nm) and diode laser (810 nm and 980 nm) devices are used to remove bacteria in infected teeth. A literature review was elaborated to compare and evaluate the advantages and disadvantages of using these lasers. Methods. Using combined search terms, eligible articles were retrieved from PubMed and printed journals. The initial search yielded 40 titles and 27 articles were assigned to full-text analysis. The studies were classified based upon laser source, laser energy level, duration/similarity of application, and initial and final bacterial count at a minimum of 20 prepared root canals. Part of the analysis was only reduced microorganisms and mechanically treated root canals upon preparation size of ISO 30. All studies were compared to evaluate the most favorable laser device for best results in endodontic therapy. Results. A total of 22 eligible studies were found regarding Nd:YAG laser 1064 nm. Four studies fulfilled all demanded criteria. Seven studies referring to the diode laser 980 nm were examined, although only one fulfilled all criteria. Eleven studies were found regarding the diode laser 810 nm, although only one study fulfilled all necessary criteria. Conclusions. Laser therapy is effective in endodontics, although a comparison of efficiency between the laser devices is not possible at present due to different study designs, materials, and equipment. PMID:27462611
Cutting and skin-ablative properties of pulsed mid-infrared laser surgery.
Kaufmann, R; Hartmann, A; Hibst, R
1994-02-01
Pulsed mid-infrared lasers allow a precise removal of soft tissues with only minimal thermal damage. To study the potential dermatosurgical usefulness of currently available systems at different wavelengths (2010-nm Thulium:YAG laser, 2100-nm Holmium:YAG laser, 2790-nm Erbium:YSGG laser, and 2940-nm Erbium:YAG laser) in vivo on pig skin. Immediate effects and wound healing of superficial laser-abrasions and incisions were compared with those of identical control lesions produced by dermabrasion, scalpel incisions, or laser surgery performed by a 1060-nm Nd:YAG and a 1060-nm CO2 laser (continuous and superpulsed mode). Best efficiency and least thermal injury was found for the pulsed Erbium:YAG laser, leading to ablative and incisional lesions comparable to those obtained by dermabrasion or superficial scalpel incisions, respectively. In contrast to other mid-infrared lasers tested, the 2940-nm Erbium:YAG laser thus provides a potential instrument for future applications in skin surgery, especially when aiming at a careful ablative removal of delicate superficial lesions with maximum sparing of adjacent tissue structures. However, in the purely incisional application mode pulsed mid-infrared lasers, though of potential usefulness in microsurgical indications (eg, surgery of the cornea), do not offer a suggestive alternative to simple scalpel surgery of the skin.
Lasers, extreme UV and soft X-ray
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nilsen, Joseph
2015-09-20
Three decades ago, large ICF lasers that occupied entire buildings were used as the energy sources to drive the first X-ray lasers. Today X-ray lasers are tabletop, spatially coherent, high-repetition rate lasers that enable many of the standard optical techniques such as interferometry to be extended to the soft X-ray regime between wavelengths of 10 and 50 nm. Over the last decade X-ray laser performance has been improved by the use of the grazing incidence geometry, diode-pumped solid-state lasers, and seeding techniques. The dominant X-ray laser schemes are the monopole collisional excitation lasers either driven by chirped pulse amplification (CPA)more » laser systems or capillary discharge. The CPA systems drive lasing in neon-like or nickel-like ions, typically in the 10 – 30 nm range, while the capillary system works best for neon-like argon at 46.9 nm. Most researchers use nickel-like ion lasers near 14 nm because they are well matched to the Mo:Si multilayer mirrors that have peak reflectivity near 13 nm and are used in many applications. As a result, the last decade has seen the birth of the X-ray free electron laser (XFEL) that can reach wavelengths down to 0.15 nm and the inner-shell Ne laser at 1.46 nm.« less
Inaba, Hajime; Hosaka, Kazumoto; Yasuda, Masami; Nakajima, Yoshiaki; Iwakuni, Kana; Akamatsu, Daisuke; Okubo, Sho; Kohno, Takuya; Onae, Atsushi; Hong, Feng-Lei
2013-04-08
We propose a novel, high-performance, and practical laser source system for optical clocks. The laser linewidth of a fiber-based frequency comb is reduced by phase locking a comb mode to an ultrastable master laser at 1064 nm with a broad servo bandwidth. A slave laser at 578 nm is successively phase locked to a comb mode at 578 nm with a broad servo bandwidth without any pre-stabilization. Laser frequency characteristics such as spectral linewidth and frequency stability are transferred to the 578-nm slave laser from the 1064-nm master laser. Using the slave laser, we have succeeded in observing the clock transition of (171)Yb atoms confined in an optical lattice with a 20-Hz spectral linewidth.
A Fiber Optic Doppler Sensor and Its Application in Debonding Detection for Composite Structures
Li, Fucai; Murayama, Hideaki; Kageyama, Kazuro; Meng, Guang; Ohsawa, Isamu; Shirai, Takehiro
2010-01-01
Debonding is one of the most important damage forms in fiber-reinforced composite structures. This work was devoted to the debonding damage detection of lap splice joints in carbon fiber reinforced plastic (CFRP) structures, which is based on guided ultrasonic wave signals captured by using fiber optic Doppler (FOD) sensor with spiral shape. Interferometers based on two types of laser sources, namely the He-Ne laser and the infrared semiconductor laser, are proposed and compared in this study for the purpose of measuring Doppler frequency shift of the FOD sensor. Locations of the FOD sensors are optimized based on mechanical characteristics of lap splice joint. The FOD sensors are subsequently used to detect the guided ultrasonic waves propagating in the CFRP structures. By taking advantage of signal processing approaches, features of the guided wave signals can be revealed. The results demonstrate that debonding in the lap splice joint results in arrival time delay of the first package in the guided wave signals, which can be the characteristic for debonding damage inspection and damage extent estimation. PMID:22219698
A fiber optic Doppler sensor and its application in debonding detection for composite structures.
Li, Fucai; Murayama, Hideaki; Kageyama, Kazuro; Meng, Guang; Ohsawa, Isamu; Shirai, Takehiro
2010-01-01
Debonding is one of the most important damage forms in fiber-reinforced composite structures. This work was devoted to the debonding damage detection of lap splice joints in carbon fiber reinforced plastic (CFRP) structures, which is based on guided ultrasonic wave signals captured by using fiber optic Doppler (FOD) sensor with spiral shape. Interferometers based on two types of laser sources, namely the He-Ne laser and the infrared semiconductor laser, are proposed and compared in this study for the purpose of measuring Doppler frequency shift of the FOD sensor. Locations of the FOD sensors are optimized based on mechanical characteristics of lap splice joint. The FOD sensors are subsequently used to detect the guided ultrasonic waves propagating in the CFRP structures. By taking advantage of signal processing approaches, features of the guided wave signals can be revealed. The results demonstrate that debonding in the lap splice joint results in arrival time delay of the first package in the guided wave signals, which can be the characteristic for debonding damage inspection and damage extent estimation.
NASA Astrophysics Data System (ADS)
Wang, Kaiwei; Wang, Xiaoping
2017-08-01
In order to enhance the practical education and hands-on experience of optoelectronics and eliminate the overlapping contents that previously existed in the experiments section adhering to several different courses, a lab course of "Applied Optoelectronics Laboratory" has been established in the College of Optical Science and Engineering, Zhejiang University. The course consists of two sections, i.e., basic experiments and project design. In section 1, basic experiments provide hands-on experience with most of the fundamental concept taught in the corresponding courses. These basic experiments including the study of common light sources such as He-Ne laser, semiconductor laser and solid laser and LED; the testing and analysis of optical detectors based on effects of photovoltaic effect, photoconduction effect, photo emissive effect and array detectors. In section 2, the course encourages students to build a team and establish a stand-alone optical system to realize specific function by taking advantage of the basic knowledge learned from section 1. Through these measures, students acquired both basic knowledge and the practical application skills. Moreover, interest in science has been developed among students.
NASA Astrophysics Data System (ADS)
Schellhas, Helmut F.; Barnes, Alfonso E.
1982-12-01
Multipurpose surgical CO2 lasers marketed in the USA have been developed to be applicable to a variety of surgical procedures in many surgical fields. They are all suited for endoscopic surgical procedures and can be fitted to all standard surgical microscopes. They all can adjust the focal length of the laser beam to the different standard focal lengths of the surgical microscope which for instance in laryngoscopy is 400 mm and in colposcopy 300 mm. One laser instrument can even change the spot size in a given focal distance which is very advantageous for some microsurgical procedures (Merrimack Laboratories 820). All multipurpose surgical CO2 laser systems provide a multi-articulated surgical arm for free-hand surgery. The surgical arms are cumbersome to use but they are adapted to the surgeons needs with ingenuity. The practicality of the multi-articulated surgical arms depends mostly on the distance of the handpiece from the surgical console which now is also overbridged by the laser tube in most surgical laser system. The spot size of the beam is variable in most handpieces by interchangeable lenses which modify the focal distance of the beam and the power density. Another common feature in all systems is a coaxial He-Ne pilot light which provides a red spot which unfortunately becomes invisible in a bleeding surgical field. Most surgical laser systems have a spacial mode of TEM 00 which is essential for incisional surgery. The continuous mode of beam delivery is used for incisional surgery and also for most endoscopic procedures.
Investigation of ASE and SRS effects on 1018nm short-wavelength Yb3+-doped fiber laser
NASA Astrophysics Data System (ADS)
Xie, Zhaoxin; Shi, Wei; Sheng, Quan; Fu, Shijie; Fang, Qiang; Zhang, Haiwei; Bai, Xiaolei; Shi, Guannan; Yao, Jianquan
2017-03-01
1018nm short wavelength Yb3+-doped fiber laser can be widely used for tandem-pumped fiber laser system in 1 μm regime because of its high brightness and low quantum defect (QD). In order to achieve 1018nm short wavelength Yb3+-doped fiber laser with high output power, a steady-state rate equations considering the amplified spontaneous emission (ASE) and Stimulated Raman Scattering (SRS) has been established. We theoretically analyzed the ASE and SRS effects in 1018nm short wavelength Yb3+-doped fiber laser and the simulation results show that the ASE is the main restriction rather than SRS for high power 1018nm short wavelength Yb3+-doped fiber laser, besides the high temperature of fiber is also the restriction for high output power. We use numerical solution of steady-state rate equations to discuss how to suppress ASE in 1018nm short wavelength fiber laser and how to achieve high power 1018nm short-wavelength fiber laser.
Biomodulation of light on cells in laser surgery
NASA Astrophysics Data System (ADS)
Liu, Timon C.; Li, Yan; Duan, Rui; Cai, Xiongwei
2002-04-01
In laser surgery, it has been observed pulsed 532-nm laser can avoid postoperative purpura, but pulsed 585-nm, 595-nm or 600-nm lasers nonetheless cause purpura when they were used to treat port-wine stains; the XeCl excimer laser (308 nm) can safely and effectively clear psoriasis; both XeCl excimer laser and Ho:YAG laser were used in coronary interventions, but only former was approved by the FDA; open channels after ultraviolet (UV) laser treatment and closed channels with infrared (IR) lasers for transmyocardial laser revascularization; and so on. In this paper, the biological information model of low intensity laser (BIML) is extended to include UVA biomodulation and is used to understand these phenomena. Although the central intensity of the laser beam is so intense that it destroys the tissue, the edge intensity is so low that it can induce biomodulation. Our investigation showed that biomodulation of light on cells might play an important role in the long-term effects of laser surgery.
Al-Karadaghi, Tamara S; Al-Saedi, Asmaa A; Al-Maliky, Mohammed A; Mahmood, Ali S
2016-12-01
This in vitro study aimed to investigate the whitening efficacy of 940 nm and 980 nm diode laser photoactivation in tooth bleaching by analysing pulp chamber temperature, as well as the change in tooth colour. Root canals of thirty extracted human lower premolars were prepared. Laserwhite* 20 bleaching agent containing 38% of hydrogen peroxide was photoactivated with 7 W output power of 940 nm and 980 nm diode lasers for 120 s. Bleaching gel reduced 27-29% of the temperature from reaching the pulp chamber. For shade assessment, only the groups photoactivated using diode lasers showed statistically significant differences from control group P < 0.001. Within the studied parameters, both 940 nm and 980 nm diode lasers produced a safe pulp temperature increase. Diode laser photoactivation of bleaching gel resulted in more efficient teeth whitening. Photoactivation with 940 nm diode laser yielded the highest change in colour with only minor increase in pulp chamber temperature. © 2016 Australian Society of Endodontology Inc.
All-fibre ytterbium laser tunable within 45 nm
DOE Office of Scientific and Technical Information (OSTI.GOV)
Abdullina, S R; Babin, S A; Vlasov, A A
2007-12-31
A tunable ytterbium-doped fibre laser is fabricated. The laser is tuned by using a tunable fibre Bragg grating (FBG) as a selecting intracavity element. The laser is tunable within 45 nm (from 1063 to 1108 nm) and emits {approx}6 W in the line of width {approx}0.15 nm, the output power and linewidth being virtually invariable within the tuning range. The method is proposed for synchronous tuning the highly reflecting and output FBGs, and a tunable ytterbium all-fibre laser is built. (lasers)
Renal denervation using focused infrared fiber lasers: a potential treatment for hypertension.
Alexander, Vinay V; Shi, Zhennan; Iftekher, Fariha; Welsh, Michael J; Gurm, Hitinder S; Rising, Gail; Yanovich, Amber; Walacavage, Kim; Islam, Mohammed N
2014-11-01
Renal denervation has recently become of great interest as a potential treatment for resistant hypertension. Denervation techniques using radio frequency (RF) or ultrasound energy sources have already been explored in literature. In this study, we investigate the use of lasers as a potential energy source for renal denervation. In vitro studies are performed in porcine/ovine renal arteries with focused laser beams at 980 nm, 1210 nm, and 1700 nm to study the ability to damage renal nerves without causing injury to non-target tissue structures like the endothelium. Then, a 980 nm laser catheter prototype is built and used to demonstrate in vivo renal denervation in ovine renal arteries. This study utilizes fiber coupled infrared lasers at 980 nm, 1210 nm, and 1700 nm. In vitro laser denervation studies at 980 nm are performed in both porcine and ovine renal arteries to study the ability of focused laser beams to damage renal nerves without injuring the endothelium. In vitro studies using lasers close to the lipid absorption lines at 1210 nm and 1700 nm are also performed in porcine renal arteries to study the possibility of selectively damaging the renal nerves by targeting the lipid myelin sheaths surrounding the nerves. Then, a laser catheter prototype is designed and built for in vivo renal denervation in ovine renal arteries using the 980 nm laser (powers ranging from 2 to 4 W, 5 seconds per exposure). Histochemical evaluations of the frozen sections are performed using methylthiazolyldiphenyl-tetrazolium bromide (MTT) assay. Histochemical analysis of in vitro laser treatments at 980 nm in porcine and ovine renal arteries show clear evidence of laser-induced renal nerve damage without injury to the endothelium and part of the media. No evidence of selective nerve damage is observed using the 1210 nm and 1700 nm lasers with the current treatment parameters. Histochemical analysis of in vivo laser treatments in ovine renal arteries using a focused 980 nm laser show clear evidence of renal nerve damage with depths of damage extending > 1.5 mm from the artery wall. Sections with laser-induced damage to the media/adventitia at depths of > 1 mm without injury to the endothelium are also observed. We demonstrate the use of focused lasers as an attractive energy source for causing renal nerve damage without injury to the artery wall and thus, may have potential therapeutic applications for conditions such as resistant hypertension, where renal denervation has been shown to be a promising form of treatment. © 2014 Wiley Periodicals, Inc.
Bargiela-Pérez, Patricia; González-Merchán, Jorge; Díaz-Sánchez, Rosa; Serrera-Figallo, Maria-Angeles; Volland, Gerd; Joergens, Martin; Gutiérrez-Pérez, Jose-Luis
2018-01-01
Background The aim of this study is to evaluate the resection of hyperplastic lesions on the buccal mucosa comparing the 532nm laser (KTP), versus diode 980nm laser, considering pain, scarring, inflammation and drug consumption that occurred postoperatively with each lasers. Material and Methods A prospective study of consecutive series of 20 patients in two groups that presents hyperplastic lesions on the buccal mucosa. The choice of the KTP laser or diode 980nm laser for the surgery was made randomly. The power used was 1.5W in both groups in a continuous wave mode with a 320 μm optical fiber. Parameters of pain, scarring, inflammation and consumption of drugs were recorded by a Numerical Rating Scale and evaluated postoperatively. These recordings were made the day of the surgery, 24 hours after, 14 and 28 days after. Results Pain and inflammation was light - moderate. The consumption of paracetamol was somewhat higher in the diode 980nm laser versus the KTP laser after 24 hours, although data was not statistically significant; significant differences were found after 28 days in regards to pain (p = 0.023) and inflammation (p = 0.023), but always in the absence parameter so we find no pain in both lasers. Scarring in the two types of laser showed no differences along the visits, with not detected scar retractable. Conclusions Although there is a slight histological difference regarding the KTP laser in the oral soft tissues for clinical use, both wavelengths are very suitable for excision of oral fibroma. Key words:Laser surgery, Laser therapy, oral surgery, soft tissue, 980 nm diode laser, 532 nm KTP laser. PMID:29274158
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cahoon, Erica M.; Almirall, Jose R.
Laser induced breakdown spectroscopy can be used for the chemical characterization of glass to provide evidence of an association between a fragment found at a crime scene to a source of glass of known origin. Two different laser irradiances, 266 nm and 1064 nm, were used to conduct qualitative and quantitative analysis of glass standards. Single-pulse and double-pulse configurations and lens-to-sample-distance settings were optimized to yield the best laser-glass coupling. Laser energy and acquisition timing delays were also optimized to result in the highest signal-to-noise ratio corresponding to the highest precision and accuracy. The crater morphology was examined and themore » mass removed was calculated for both the 266 nm and 1064 nm irradiations. The analytical figures of merit suggest that the 266 nm and 1064 nm wavelengths are capable of good performance for the forensic chemical characterization of glass. The results presented here suggest that the 266 nm laser produces a better laser-glass matrix coupling, resulting in a better stoichiometric representation of the glass sample. The 266 nm irradiance is therefore recommended for the forensic analysis and comparison of glass samples.« less
Surface microstructure and chemistry of polyimide by single pulse ablation of picosecond laser
NASA Astrophysics Data System (ADS)
Du, Qifeng; Chen, Ting; Liu, Jianguo; Zeng, Xiaoyan
2018-03-01
Polyimide (PI) surface was ablated by the single pulse of picosecond laser, and the effects of laser wavelength (λ= 355 nm and 1064 nm) and fluence on surface microstructure and chemistry were explored. Scanning electron microscopy (SEM) analysis found that different surface microstructures, i.e., the concave of concentric ring and the convex of porous circular disk, were generated by 355 nm and 1064 nm picosecond laser ablation, respectively. X-ray photoelectron spectroscopy (XPS) characterization indicated that due to the high peak energy density of picosecond laser, oxygen and nitrogen from the ambient were incorporated into the PI surface mainly in the form of Cdbnd O and Csbnd Nsbnd C groups. Thus, both of the O/C and N/C atomic content ratios increased, but the increase caused by 1064 nm wavelength laser was larger. It inferred that the differences of PI surface microstructures and chemistry resulted from different laser parameters were related to different laser-matter interaction effects. For 355 nm picosecond laser, no obvious thermal features were observed and the probable ablation process of PI was mainly governed by photochemical effect; while for 1064 nm picosecond laser, obvious thermal feature appeared and photothermal effect was thought to be dominant.
NASA Astrophysics Data System (ADS)
Zhu, Pengfei; Zhang, Chaomin; Zhu, Kun; Ping, Yunxia; Song, Pei; Sun, Xiaohui; Wang, Fuxin; Yao, Yi
2018-03-01
We demonstrate an efficient and compact ultraviolet laser at 303 nm generated by intracavity frequency doubling of a continuous wave (CW) laser diode-pumped Pr3+:YLiF4 laser at 607 nm. A cesium lithium borate (CLBO) crystal, cut for critical type I phase matching at room temperature, is used for second-harmonic generation (SHG) of the fundamental laser. By using an InGaN laser diode array emitting at 444.3 nm with a maximum incident power of 10 W, as high as 68 mW of CW output power at 303 nm is achieved. The output power stability in 4 h is better than 2.85%. To the best of our knowledge, this is high efficient UV laser generated by frequency doubling of an InGaN laser diode array pumped Pr3+:YLiF4 laser.
Havel, Miriam; Betz, Christian S; Leunig, Andreas; Sroka, Ronald
2014-08-01
The basic difference between the various common medical laser systems is the wavelength of the emitted light, leading to altered light-tissue interactions due to the optical parameters of the tissue. This study examines laser induced tissue effects in an in vitro tissue model using 1,470 nm diode laser compared to our standard practice for endonasal applications (940 nm diode laser) under standardised and reproducible conditions. Additionally, in vivo induced tissue effects following non-contact application with focus on mucosal healing were investigated in a controlled intra-individual design in patients treated for hypertrophy of nasal turbinate. A certified diode laser system emitting the light of λ = 1470 nm was evaluated with regards to its tissue effects (ablation, coagulation) in an in vitro setup on porcine liver and turkey muscle tissue model. To achieve comparable macroscopic tissue effects the laser fibres (600 µm core diameter) were fixed to a computer controlled stepper motor and the laser light was applied in a reproducible procedure under constant conditions. For the in vivo evaluation, 20 patients with nasal obstruction due to hyperplasia of inferior nasal turbinates were included in this prospective randomised double-blinded comparative trial. The endoscopic controlled endonasal application of λ = 1470 nm on the one and λ = 940 nm on the other side, both in 'non-contact' mode, was carried out as an outpatient procedure under local anaesthesia. The postoperative wound healing process (mucosal swelling, scab formation, bleeding, infection) was endoscopically documented and assessed by an independent physician. In the experimental setup, the 1,470 nm laser diode system proved to be efficient in inducing tissue effects in non-contact mode with a reduced energy factor of 5-10 for highly perfused liver tissue to 10-20 for muscle tissue as compared to the 940 nm diode laser system. In the in vivo evaluation scab formation following laser surgery as assessed clinically on endonasal endoscopy was significantly reduced on 1,470 nm treated site compared to 940 nm diode laser treated site. Diode laser system (1,470 nm) induces efficient tissue effects compared to 940 nm diode laser system as shown in the tissue model experiment. From the clinical point of view, the healing process following non-contact diode laser application revealed to be improved using 1,470 nm diode laser compared to our standard diode laser practise with 940 nm. © 2014 Wiley Periodicals, Inc.
Discrete multi-wavelength tuning of a continuous wave diode-pumped Nd:GdVO4 laser
NASA Astrophysics Data System (ADS)
Nadimi, Mohammad; Waritanant, Tanant; Major, Arkady
2018-05-01
Discrete multi-wavelength operation of a diode-pumped Nd:GdVO4 laser at four different wavelengths was demonstrated using a single birefringent filter plate. The laser achieved maximum output powers of 5.92 W, 5.66 W, 5.56 W and 3.98 W at 1063.2 nm, 1070.8 nm, 1082.5 nm and 1086.2 nm wavelengths, respectively. To the best of our knowledge, apart from achieving the maximum output powers at ~1071 nm and ~1086 nm and best efficiencies at ~1071 nm, ~1083 nm and ~1086 nm wavelengths for a Nd:GdVO4 laser, this is also the largest number of wavelengths from the 4F3/2 → 4I11/2 transition that was ever obtained in a controlled manner from a single laser setup based on any of the Nd-doped laser crystals.
NASA Technical Reports Server (NTRS)
Nash-Stevenson, S. K.; Reddy, B. R.; Venkateswarlu, P.
1994-01-01
A summary is presented of the spectroscopic study of three systems: LaF3:Ho(3+), LaF3:Er(3+) and CaF2:Nd(3+). When the D levels of Ho(3+) in LaF3 were resonantly excited with a laser beam of 640 nm, upconverted emissions were detected from J (416 nm), F (485 nm), and E (546 nm) levels. Energy upconverted emissions were also observed from F and E levels of Ho(3+) when the material was excited with an 800 nm near infrared laser. When the D levels of Er(3+) in LaF3 were resonantly excited with a laser beam of 637 nm, upconverted emissions were detected from the E (540 nm) and P (320, 400, and 468 nm) levels. Energy upconverted emissions were also observed from F, E, and D levels of Er(3+) when the material was resonantly excited with an 804 nm near infrared laser. When the D levels of Nd(3+) in CaF2 were resonantly excited with a laser beam of 577 nm, upconverted emissions were detected from the L (360 and 382 nm), K (418 nm), and I (432 nm) levels. Very weak upconverted emissions were detected when this system was irradiated with a near infrared laser. The numbers in parentheses are the wavelengths of the emissions.
NASA Astrophysics Data System (ADS)
Bugge, F.; Bege, R.; Blume, G.; Feise, D.; Sumpf, B.; Werner, N.; Zeimer, U.; Paschke, K.; Weyers, M.
2018-06-01
Highly strained InxGa1-xAs QWs are commonly used for laser diodes in the wavelength range beyond 1100 nm, but they suffer from strain induced formation of defects. The effect of different laser structures and different laser layouts on the aging behavior was investigated. If grown and processed under optimized conditions, laser diodes emitting at 1120 nm, 1156 nm and 1180 nm have lifetimes of several 1000 h up to more than 20,000 h in dependence on structure or indium content. Laser diodes with three different emission wavelength were mounted in a microoptical bench with a second harmonic generation crystal. From these benches laser emission in the green-yellow spectral range with more than 800 mW output power was obtained.
Laser action in chromium-activated forsterite for near infrared excitation
NASA Technical Reports Server (NTRS)
Petricevic, V.; Gayen, S. K.; Alfano, R. R.
1988-01-01
This paper reports on laser action in chromium-doped forsterite (Cr:Mg2SiO4) for 1064-nm excitation of the crystal's double-hump absorption band spanning the 850-1200-nm wavelength range. The cavity arrangement used for obtaining laser action in Cr:Mg2SiO2 was similar to that described by Petricevic et al. (1988). The fundamental and second harmonic emissions from a Q-switched Nd:YAG laser operating at a 10-Hz repetition rate were used for excitation of the NIR and visible bands, respectively. Pulsed laser action was readily observed for both the 1064-nm and 532-nm pumping at or above the respective thresholds. The laser parameters of the 532-nm and 1064-nm excitations were similar, indicating that the IR band is responsible for laser action for both excitations.
Asnaashari, Mohamad; Ebad, Leila Tahmasebi; Shojaeian, Shiva
2016-10-01
Background and aim: Use of laser technology in endodontics has greatly increased in the recent years due to the introduction of new wavelengths and methods and optimal antimicrobial and smear layer removal properties of lasers. This in vitro study aimed to compare the antibacterial effects of diode lasers of 810 nm and 980 nm wavelength on Enterococcus faecalis (E. faecalis) biofilm in the root canal system. Materials and methods: Fifty single-canal human anterior teeth were cleaned, shaped, sterilized and randomly divided into four groups namely two experimental, one positive and one negative control group. The experimental and positive control groups were inoculated with E. faecalis and incubated for two weeks. The experimental group one (n=20) received 810 nm diode laser irradiation (1.5W) while the experimental group two (n=20) was subjected to 980 nm diode laser irradiation (1.5W). The E. faecalis colony forming units (CFUs) were counted in each root canal before and after laser irradiation. Results: Laser irradiation significantly decreased the bacterial colony count in both experimental groups. The reduction in microbial count was significantly greater in 810 nm laser group compared to 980 nm laser group. Conclusion: Irradiation of both 810 and 980 nm lasers significantly decreased the E. faecalis count in the root canal system; 810 nm laser was more effective in decreasing the intracanal microbial load.
Asnaashari, Mohamad; Ebad, Leila Tahmasebi
2016-01-01
Background and aim: Use of laser technology in endodontics has greatly increased in the recent years due to the introduction of new wavelengths and methods and optimal antimicrobial and smear layer removal properties of lasers. This in vitro study aimed to compare the antibacterial effects of diode lasers of 810 nm and 980 nm wavelength on Enterococcus faecalis (E. faecalis) biofilm in the root canal system. Materials and methods: Fifty single-canal human anterior teeth were cleaned, shaped, sterilized and randomly divided into four groups namely two experimental, one positive and one negative control group. The experimental and positive control groups were inoculated with E. faecalis and incubated for two weeks. The experimental group one (n=20) received 810 nm diode laser irradiation (1.5W) while the experimental group two (n=20) was subjected to 980 nm diode laser irradiation (1.5W). The E. faecalis colony forming units (CFUs) were counted in each root canal before and after laser irradiation. Results: Laser irradiation significantly decreased the bacterial colony count in both experimental groups. The reduction in microbial count was significantly greater in 810 nm laser group compared to 980 nm laser group. Conclusion: Irradiation of both 810 and 980 nm lasers significantly decreased the E. faecalis count in the root canal system; 810 nm laser was more effective in decreasing the intracanal microbial load. PMID:27853346
Compact Ozone Differential Absorption Lidar (DIAL) Transmitter Using Solid-State Dye Polymers
NASA Technical Reports Server (NTRS)
Jones, Alton L., Jr.; DeYoung, Russell J.; Elsayid-Ele, Hani
2001-01-01
A new potential DIAL laser transmitter is described that uses solid-state dye laser materials to make a simpler, more compact, lower mass laser system. Two solid-state dye laser materials were tested to evaluate their performance in a laser oscillator cavity end pumped by a pulsed Nd:YAG laser at 532 nm. The polymer host polymethyl-methacrylate was injected with a pyrromethene laser dye, PM 580, or PM 597. A narrowband laser oscillator cavity was constructed to produce visible wavelengths of 578 and 600 nm which were frequency doubled into the UV region (299 or 300 nm) by using a BBO crystal, resulting in a maximum energy of 11 mJ at a wavelength of 578 nm when pumped by the Nd:YAG laser at an energy of 100 mJ (532 nm). A maximum output energy of 378 microJ was achieved in the UV region at a wavelength of 289 nm but lasted only 2000 laser shots at a repetition rate of 10 Hz. The results are promising and show that a solid-state dye laser based ozone DIAL system is possible with improvements in the design of the laser transmitter.
Jin, Xiaoxi; Du, Xueyuan; Wang, Xiong; Zhou, Pu; Zhang, Hanwei; Wang, Xiaolin; Liu, Zejin
2016-01-01
We demonstrated a high-power ultralong-wavelength Tm-doped silica fiber laser operating at 2153 nm with the output power exceeding 18 W and the slope efficiency of 25.5%. A random distributed feedback fiber laser with the center wavelength of 1173 nm was employed as pump source of Tm-doped fiber laser for the first time. No amplified spontaneous emissions or parasitic oscillations were observed when the maximum output power reached, which indicates that employing 1173 nm random distributed feedback fiber laser as pump laser is a feasible and promising scheme to achieve high-power emission of long-wavelength Tm-doped fiber laser. The output power of this Tm-doped fiber laser could be further improved by optimizing the length of active fiber, reflectivity of FBGs, increasing optical efficiency of pump laser and using better temperature management. We also compared the operation of 2153 nm Tm-doped fiber lasers pumped with 793 nm laser diodes, and the maximum output powers were limited to ~2 W by strong amplified spontaneous emission and parasitic oscillation in the range of 1900–2000 nm. PMID:27416893
Jin, Xiaoxi; Du, Xueyuan; Wang, Xiong; Zhou, Pu; Zhang, Hanwei; Wang, Xiaolin; Liu, Zejin
2016-07-15
We demonstrated a high-power ultralong-wavelength Tm-doped silica fiber laser operating at 2153 nm with the output power exceeding 18 W and the slope efficiency of 25.5%. A random distributed feedback fiber laser with the center wavelength of 1173 nm was employed as pump source of Tm-doped fiber laser for the first time. No amplified spontaneous emissions or parasitic oscillations were observed when the maximum output power reached, which indicates that employing 1173 nm random distributed feedback fiber laser as pump laser is a feasible and promising scheme to achieve high-power emission of long-wavelength Tm-doped fiber laser. The output power of this Tm-doped fiber laser could be further improved by optimizing the length of active fiber, reflectivity of FBGs, increasing optical efficiency of pump laser and using better temperature management. We also compared the operation of 2153 nm Tm-doped fiber lasers pumped with 793 nm laser diodes, and the maximum output powers were limited to ~2 W by strong amplified spontaneous emission and parasitic oscillation in the range of 1900-2000 nm.
Diode-pumped continuous-wave eye-safe Nd:YAG laser at 1415 nm.
Lee, Hee Chul; Byeon, Sung Ug; Lukashev, Alexei
2012-04-01
We describe the output performance of the 1415 nm emission in Nd:YAG in a plane-concave cavity under traditional pumping into the 4F5/2 level (808 nm) and direct in-band pumping into the 4F3/2 level (885 nm). An end-pumped Nd:YAG laser yielded maximum cw output power of 6.3 W and 4.2 W at 885 nm and 808 nm laser diode (LD) pumping, respectively. To the best of our knowledge, this is the highest output power of a LD-pumped 1415 nm laser.
NASA Astrophysics Data System (ADS)
Sroka, Ronald; Havel, Miriam; Leunig, Andreas; Betz, Christian S.
2012-02-01
Introduction: So far various laser systems have been used for volume reduction of hyperplastic nasal turbinates. In case of endonasal application, fiber controlled diode lasers are preferred due to reasons of cost and practicability. The aim of this clinical study was to compare the coagulative tissue effects using either λ=1470nm vs. λ=940nm emitting lasers in treatment of hyperplastic inferior nasal turbinates in an intraindividual manner. Patients and methods: This prospective, randomized, double-blind, clinical feasibility trial included 20 patients suffering from hyperplastic inferior nasal turbinates. In each case, one nasal cavity was treated using 1470nm laser at 4- 5W, the other one with 940nm laser at 12W. Treatment was performed endoscopically controlled in non-contact mode. Clinical presentation and patients symptoms were documented preoperatively and on day 1, 3, 7, 14 and 21 postoperatively using rhinomanometry, standardized questionnaires including SNOT 20 GAV (German adapted version), and separate endoscopic examination respectively. Results: None of the patients showed infections, hemorrhages or other complications occurred intra- or postoperatively. The mean operation time was significantly shorter using the 1470nm diode laser as compared to the 940nm laser, thus lower energy was applied. There was a significant reduction of nasal obstruction on day 21 postoperatively compared to the preoperative condition on both sides regardless of the laser system used. Evaluation of the SNOT-Scores as assessed before and three weeks after surgery showed significant subjective improvements. Conclusion: Compared with standard application of 940nm diode laser, 1470nm diode laser application provides an equivalent tissue reduction in shorter operation time using less total energy and a comparable relief of nasal obstruction postoperatively.
A High Power, Frequency Tunable Colloidal Quantum Dot (CdSe/ZnS) Laser
Prasad, Saradh; Saleh AlHesseny, Hanan; AlSalhi, Mohamad S.; Devaraj, Durairaj; Masilamai, Vadivel
2017-01-01
Tunable lasers are essential for medical, engineering and basic science research studies. Most conventional solid-state lasers are capable of producing a few million laser shots, but limited to specific wavelengths, which are bulky and very expensive. Dye lasers are continuously tunable, but exhibit very poor chemical stability. As new tunable, efficient lasers are always in demand, one such laser is designed with various sized CdSe/ZnS quantum dots. They were used as a colloid in tetrahydrofuran to produce a fluorescent broadband emission from 520 nm to 630 nm. The second (532 nm) and/or third harmonic (355 nm) of the Nd:YAG laser (10 ns, 10 Hz) were used together as the pump source. In this study, different sized quantum dots were independently optically pumped to produce amplified spontaneous emission (ASE) with 4 nm to 7 nm of full width at half-maximum (FWHM), when the pump power and focusing were carefully optimized. The beam was directional with a 7 mrad divergence. Subsequently, these quantum dots were combined together, and the solution was placed in a resonator cavity to obtain a laser with a spectral width of 1 nm and tunable from 510 to 630 nm, with a conversion efficiency of about 0.1%. PMID:28336863
A High Power, Frequency Tunable Colloidal Quantum Dot (CdSe/ZnS) Laser.
Prasad, Saradh; AlHesseny, Hanan Saleh; AlSalhi, Mohamad S; Devaraj, Durairaj; Masilamai, Vadivel
2017-01-30
Tunable lasers are essential for medical, engineering and basic science research studies. Most conventional solid-state lasers are capable of producing a few million laser shots, but limited to specific wavelengths, which are bulky and very expensive. Dye lasers are continuously tunable, but exhibit very poor chemical stability. As new tunable, efficient lasers are always in demand, one such laser is designed with various sized CdSe/ZnS quantum dots. They were used as a colloid in tetrahydrofuran to produce a fluorescent broadband emission from 520 nm to 630 nm. The second (532 nm) and/or third harmonic (355 nm) of the Nd:YAG laser (10 ns, 10 Hz) were used together as the pump source. In this study, different sized quantum dots were independently optically pumped to produce amplified spontaneous emission (ASE) with 4 nm to 7 nm of full width at half-maximum (FWHM), when the pump power and focusing were carefully optimized. The beam was directional with a 7 mrad divergence. Subsequently, these quantum dots were combined together, and the solution was placed in a resonator cavity to obtain a laser with a spectral width of 1 nm and tunable from 510 to 630 nm, with a conversion efficiency of about 0.1%.
Efficiency of soft tissue incision with a novel 445-nm semiconductor laser.
Braun, Andreas; Kettner, Moritz; Berthold, Michael; Wenzler, Johannes-Simon; Heymann, Paul Günther Baptist; Frankenberger, Roland
2018-01-01
Using a 445-nm semiconductor laser for tissue incision, an effective cut is expected due to the special absorption properties of blue laser light in soft tissues. The aim of the present study was the histological evaluation of tissue samples after incision with a 445-nm diode laser. Forty soft tissue specimens were obtained from pork oral mucosa and mounted on a motorized linear translation stage. The handpiece of a high-frequency surgery device, a 970-nm semiconductor laser, and a 445-nm semiconductor laser were connected to the slide, allowing a constant linear movement (2 mm/s) and the same distance of the working tip to the soft tissue's surface. Four incisions were made each: (I) 970-nm laser with conditioned fiber tip, contact mode at 3-W cw; (II-III): 445-nm laser with non-conditioned fiber tip, contact mode at 2-W cw, and non-contact mode (1 mm) at 2 W; and (IV): high-frequency surgery device with straight working tip, 90° angulation, contact mode at 50 W. Histological analysis was performed after H&E staining of the embedded specimens at 35-fold magnification. The comparison of the incision depths showed a significant difference depending on the laser wavelength and the selected laser parameters. The highest incision depth was achieved with the 445-nm laser contact mode (median depth 0.61 mm, min 0.26, max 1.17, interquartile range 0.58) (p < 0.05) with the lowest amount of soft tissue denaturation (p < 0.05). The lowest incision depth was measured for the high-frequency surgical device (median depth 0.36 mm, min 0.12, max 1.12, interquartile range 0.23) (p < 0.05). Using a 445-nm semiconductor laser, a higher cutting efficiency can be expected when compared with a 970-nm diode laser and high-frequency surgery. Even the 445-nm laser application in non-contact mode shows clinically acceptable incision depths without signs of extensive soft tissue denaturation.
Laser diode and pumped Cr:Yag passively Q-switched yellow-green laser at 543 nm
NASA Astrophysics Data System (ADS)
Yao, Y.; Ling, Zhao; Li, B.; Qu, D. P.; Zhou, K.; Zhang, Y. B.; Zhao, Y.; Zheng, Q.
2013-03-01
Efficient and compact yellow green pulsed laser output at 543 nm is generated by frequency doubling of a passively Q-switched end diode-pumped Nd:YVO4 laser at 1086 nm under the condition of sup-pressing the higher gain transition near 1064 nm. With 15 W of diode pump power and the frequency doubling crystal LBO, as high as 1.58 W output power at 543 nm is achieved. The optical to optical conversion efficiency from the corresponding Q-switched fundamental output to the yellow green output is 49%. The peak power of the Q-switched yellow green pulse laser is up to 30 kW with 5 ns pulse duration. The output power stability over 8 hours is better than 2.56% at the maximum output power. To the best of our knowledge, this is the highest watt-level laser at 543 nm generated by frequency doubling of a passively Q-switched end diode pumped Nd:YVO4 laser at 1086 nm.
Comparison of 193 nm and 308 nm laser liquid printing by shadowgraphy imaging
NASA Astrophysics Data System (ADS)
Palla-Papavlu, A.; Shaw-Stewart, J.; Mattle, T.; Dinca, V.; Lippert, T.; Wokaun, A.; Dinescu, M.
2013-08-01
Over the last years laser-induced forward transfer has emerged as a versatile and powerful tool for engineering surfaces with active compounds. Soft, easily damageable materials can be transferred using a triazene polymer as a sacrificial layer which acts as a pressure generator and at the same time protects the material from direct laser irradiation. To understand and optimize the transfer process of biomolecules in liquid solution by using an intermediate triazene polymer photosensitive layer, shadowgraphy imaging is carried out. Two laser systems i.e. an ArF laser operating at 193 nm and a XeCl laser operating at 308 nm are applied for the transfer. Solutions with 50% v/v glycerol concentration are prepared and the influence of the triazene polymer sacrificial layer thickness (60 nm) on the deposits is studied. The shadowgraphy images reveal a pronounced difference between laser-induced forward transfer using 193 nm or 308 nm, i.e. very different shapes of the ejected liquid.
Elsaie, Mohamed L; Ibrahim, Shady M; Saudi, Wael
2018-01-01
Introduction: Non-ablative fractional erbium-doped glass 1540 nm and fractional ablative 10600 nm carbon dioxide lasers are regarded as effective modalities for treating acne atrophic scars. In this study, we aimed to compare the effectiveness of fractional CO 2 laser and fractional nonablative 1540 nm erbium doped glass laser in treating post acne atrophic scars in Egyptian patients. Methods: Fifty-eight patients complaining of moderate and severe acne atrophic scars were randomly divided into 2 groups of 29 patients each. Both groups were subjected to 4 treatment sessions with 3 weeks interval and were followed up for 3 months. In group A, enrolled patient sreceived C2 laser, while in group B, patients were treated with 1540 nm erbium glass fractional laser. Results: Clinical assessment revealed that the mean grades of progress and improvement were higher with fractional 10600 nm CO2 laser but with non-significant difference between both treatments ( P = 0.1). The overall patients' satisfaction with both lasers were not significantly different ( P = 0.44). Conclusion: Both fractional ablative CO2 and fractional non-ablative erbium glass lasers are good modalities for treating acne scars with a high efficacy and safety profile and good patient satisfaction. The fractional ablative laser showed higher efficacy while non-ablative laser offered less pain and shorter downtime.
NASA Astrophysics Data System (ADS)
Vinnichenko, Victoriya; Kovalenko, Anastasiya; Arkhipova, Valeriya; Yaroslavsky, Ilya; Altshuler, Gregory; Gapontsev, Valentin
2018-02-01
Three lasers were directly compared, including the Ho:YAG laser (λ = 2100 nm), Tm fiber laser (λ = 1940 nm) operating in 3 different modes (CW, regular pulse, and super pulse), and blue diode laser (λ = 442 nm) for vaporization and coagulation efficiency for treating blood-rich soft tissues, ex vivo, in a porcine kidney model at quasi-contact cutting in water. In addition, experimental results were compared with published data on performance of KTP laser (λ = 532 nm) at similar experimental settings (Power = 60 W and cutting speed = 2 mm/s). Tm fiber laser in pulsed mode and blue laser produced highest vaporization rates of 3.7 and 3.4 mm3/s, respectively. Tm fiber laser (in both CW and pulsed modes) also produced the largest coagulation zone among the laser sources tested. A carbonization zone was observed for Tm fiber laser in CW and pulsed modes, as well as for the blue diode laser. Tm fiber laser in super-pulse mode and Ho:YAG laser both resulted in irregular coagulation zones without carbonization. Comparison with known data for KTP laser revealed that tissue effects of the blue laser are similar to that of the KTP laser. These results suggest that the combination of the two lasers (Tm fiber and blue diode) in one system may achieve high cutting efficiency and optimal coagulation for hemostasis during surgical treatment. Ex vivo testing of the combined system revealed feasibility of this approach. The combination of the CW Tm fiber laser (120W) and the blue diode laser (60W) emitting through a combination tip were compared with CW 120 W Tm fiber laser alone and 120 W Ho:YAG laser. Vaporization rates measured 34, 28, and 6 mm3/s, and coagulation zones measured 0.6, 1.3, and 1.7 mm, respectively. A carbonization zone was only observed with CW Tm fiber laser. The vaporization rate of combined CW Tm fiber laser / blue diode laser was comparable to published data for KTP laser for equivalent total power. Thus, high-power blue diode laser, Tm fiber laser, and their combination may provide an alternative to conventional Ho:YAG and KTP lasers for applications in urology and other surgical fields.
Near-infrared lasers and self-frequency-doubling in Nd:YCOB cladding waveguides.
Ren, Yingying; Chen, Feng; Vázquez de Aldana, Javier R
2013-05-06
A design of cladding waveguides in Nd:YCOB nonlinear crystals is demonstrated in this work. Compact Fabry-Perot oscillation cavities are employed for waveguide laser generation at 1062 nm and self-frequency-doubling at 531 nm, under optical pump at 810 nm. The waveguide laser shows slope efficiency as high as 55% at 1062 nm. The SFD green waveguide laser emits at 531 nm with a maximum power of 100 μW.
Nonlinear excitation fluorescence microscopy: source considerations for biological applications
NASA Astrophysics Data System (ADS)
Wokosin, David L.
2008-02-01
Ultra-short-pulse solid-state laser sources have improved contrast within fluorescence imaging and also opened new windows of investigation in biological imaging applications. Additionally, the pulsed illumination enables harmonic scattering microscopy which yields intrinsic structure, symmetry and contrast from viable embryos, cells and tissues. Numerous human diseases are being investigated by the combination of (more) intact dynamic tissue imaging of cellular function with gene-targeted specificity and electrophysiology context. The major limitation to more widespread use of multi-photon microscopy has been the complete system cost and added complexity above and beyond commercial camera and confocal systems. The current status of all-solid-state ultrafast lasers as excitation sources will be reviewed since these lasers offer tremendous potential for affordable, reliable, "turnkey" multiphoton imaging systems. This effort highlights the single box laser systems currently commercially available, with defined suggestions for the ranges for individual laser parameters as derived from a biological and fluorophore limited perspective. The standard two-photon dose is defined by 800nm, 10mW, 200fs, and 80Mhz - at the sample plane for tissue culture cells, i.e. after the full scanning microscope system. Selected application-derived excitation wavelengths are well represented by 700nm, 780nm, ~830nm, ~960nm, 1050nm, and 1250nm. Many of the one-box lasers have fixed or very limited excitation wavelengths available, so the lasers will be lumped near 780nm, 800nm, 900nm, 1050nm, and 1250nm. The following laser parameter ranges are discussed: average power from 200mW to 2W, pulse duration from 70fs to 700fs, pulse repetition rate from 20MHz to 200MHz, with the laser output linearly polarized with an extinction ratio at least 100:1.
Compressible Fabry-Perot refractometer.
Andersson, M; Eliasson, L; Pendrill, L R
1987-11-15
The use of a long, thermally stable Fabry-Perot etalon as a refractometer is considered in detail in this study of the refractive index of air. The etalon consists of two flat plates of fused silica 60 mm in diameter, with a cylindrical spacer made of Zerodur (a polycrystalline glass ceramic of extremely low thermal expansion) 200 mm long. The interferogram of light from a frequency-stabilized He-Ne laser is imaged with large-diameter mirror optics. The principal result is a demonstration of the effects of changes in atmospheric pressure on the etalon. The measured refractive-index values deviate by 2 parts in 10(7) from calculated values. Possible causes of error are considered in detail.
Holographic Interferometry of Oil Films and Droplets in Water with a Single-Beam Mirror-Type Scheme
2011-03-01
A simple scheme of holographic interferometry is shown in Fig. 1. A beam from an He-Ne laser (wave- length 0.632/ym), expanded by a lens (F-5cm...1 March 2011 r\\i rii cos 9 - ra2cos9f fii cos 9 + n2cos9, 2nj cos 9 t\\2 = 1 + r\\2 nx cos 9 + n2cos9, (3) Here 9r is the transmission angle ...which is related to the incidence angle by cos 9, — .11 - I tii sin9\\2 n% It follows from Eq. (3) that, for n2 > «i (as in our case of the air
Design of a real-time two-color interferometer for MAST Upgrade
DOE Office of Scientific and Technical Information (OSTI.GOV)
O’Gorman, T., E-mail: thomas.ogorman@ccfe.ac.uk; Naylor, G.; Scannell, R.
2014-11-15
A single chord two-color CO{sub 2}/HeNe (10.6/0.633 μm) heterodyne laser interferometer has been designed to measure the line integral electron density along the mid-plane of the MAST Upgrade tokamak, with a typical error of 1 × 10{sup 18} m{sup −3} (∼2° phase error) at 4 MHz temporal resolution. To ensure this diagnostic system can be restored from any failures without stopping MAST Upgrade operations, it has been located outside of the machine area. The final design and initial testing of this system, including details of the optics, vibration isolation, and a novel phase detection scheme are discussed in this paper.
Coherent diffraction surface imaging in reflection geometry.
Marathe, Shashidhara; Kim, S S; Kim, S N; Kim, Chan; Kang, H C; Nickles, P V; Noh, D Y
2010-03-29
We present a reflection based coherent diffraction imaging method which can be used to reconstruct a non periodic surface image from a diffraction amplitude measured in reflection geometry. Using a He-Ne laser, we demonstrated that a surface image can be reconstructed solely from the reflected intensity from a surface without relying on any prior knowledge of the sample object or the object support. The reconstructed phase image of the exit wave is particularly interesting since it can be used to obtain quantitative information of the surface depth profile or the phase change during the reflection process. We believe that this work will broaden the application areas of coherent diffraction imaging techniques using light sources with limited penetration depth.
Optical design of f-theta lens for dual wavelength selective laser melting
NASA Astrophysics Data System (ADS)
Feng, Lianhua; Cao, Hongzhong; Zhang, Ning; Xu, Xiping; Duan, Xuanming
2016-10-01
F-theta lens is an important unit for selective laser melting (SLM) manufacture. The dual wavelength f-theta lens has not been used in SLM manufacture. Here, we present the design of the f-theta lens which satisfies SLM manufacture with coaxial 532 nm and 1030 nm 1080 nm laser beams. It is composed of three pieces of spherical lenses. The focal spots for 532 nm laser and 1030 nm 1080 nm laser are smaller than 35 μm and 70 μm, respectively. The results meet the demands of high precision SLM. The chromatic aberration could cause separation between two laser focal spots in the scanning plane, so chromatic aberration correction is very important to our design. The lateral color of the designed f-theta lens is less than 11 μm within the scan area of 150 mm x 150 mm, which meet the application requirements of dual wavelength selective laser melting.
NASA Astrophysics Data System (ADS)
Gulgazov, Vadim N.; Jackson, Gordon S.; Lascola, Kevin M.; Major, Jo S.; Parke, Ross; Richard, Tim; Rossin, Victor V.; Zhang, Kai
1999-09-01
The demands of global bandwidth and distribution are rising rapidly as Internet usage grows. This fundamentally means that more photons are flowing within optical cables. While transmitting sources launches some optical power, the majority of the optical power that is present within modern telecommunication systems originates from optical amplifiers. In addition, modern optical amplifiers offer flat optical gain over broad wavelength bands, thus making possible dense wavelength de-multiplexing (DWDM) systems. Optical amplifier performance, and by extension the performance of the laser pumps that drive them, is central to the future growth of both optical transmission and distribution systems. Erbium-doped amplifiers currently dominate optical amplifier usage. These amplifiers absorb pump light at 980 nm and/or 1480 nm, and achieve gain at wavelengths around 1550 nm. 980 nm pumps achieve better noise figures and are therefore used for the amplification of small signals. Due to the quantum defect, 1480 nm lasers deliver more signal photon per incident photon. In addition, 1480 nm lasers are less expensive than 980 nm lasers. Thus, 1480 nm pump lasers are used for amplification in situations where noise is not critical. The combination of these traits leads to the situation where many amplifiers contain 980 nm lasers to pump the input section of the Er- doped fiber with 1480 nm lasers being used to pump the latter section of Er fiber. This can be thought of as using 980 nm lasers to power an optical pre-amplifier with the power amplification function being pump with 1480 nm radiation. This paper will focus on 980 nm pump lasers and the impact that advances in 980 nm pump technology will have on optical amplification systems. Currently, 980 nm technology is rapidly advancing in two areas, power and reliability. Improving reliability is becoming increasingly important as amplifiers move towards employing more pump lasers and using these pump lasers without redundancy. Since the failure rate allowable for an amplifier is not a function of the number of pumps employed in the amplifier, the allowable failure rate of an individual pump laser is decreasing for next-generation amplifiers. This will lead to specifications for terrestrial pumps well below 1000 FIT, and may lead to the case where high power amplifiers need laser pump reliability to approach 100 FIT. In addition, 980 nm laser diodes are now being deployed in submarine systems where failure rates lower than 100 FIT are commonly specified. It is obvious that both terrestrial and submarine markets are pushing allowable failure rates for pumps for optical amplifiers to continually decrease. A second push for improvement is in the output power of 980 nm pump modules. There exist a number of motivations for increasing the output power of pump lasers. First, each additional channel in a DWDM system requires additional power. To first order, a doubling in channel count implies a doubling in pump power. Second, larger amplifiers require multiple pumps. Higher output power from pump modules allows for fewer pumps, less complicated control systems and smaller size amplifiers. The discussion of this paper will focus on how current development progress of 980 nm laser diodes addresses these issues: better reliability and higher output powers.
High power diode lasers emitting from 639 nm to 690 nm
NASA Astrophysics Data System (ADS)
Bao, L.; Grimshaw, M.; DeVito, M.; Kanskar, M.; Dong, W.; Guan, X.; Zhang, S.; Patterson, J.; Dickerson, P.; Kennedy, K.; Li, S.; Haden, J.; Martinsen, R.
2014-03-01
There is increasing market demand for high power reliable red lasers for display and cinema applications. Due to the fundamental material system limit at this wavelength range, red diode lasers have lower efficiency and are more temperature sensitive, compared to 790-980 nm diode lasers. In terms of reliability, red lasers are also more sensitive to catastrophic optical mirror damage (COMD) due to the higher photon energy. Thus developing higher power-reliable red lasers is very challenging. This paper will present nLIGHT's released red products from 639 nm to 690nm, with established high performance and long-term reliability. These single emitter diode lasers can work as stand-alone singleemitter units or efficiently integrate into our compact, passively-cooled Pearl™ fiber-coupled module architectures for higher output power and improved reliability. In order to further improve power and reliability, new chip optimizations have been focused on improving epitaxial design/growth, chip configuration/processing and optical facet passivation. Initial optimization has demonstrated promising results for 639 nm diode lasers to be reliably rated at 1.5 W and 690nm diode lasers to be reliably rated at 4.0 W. Accelerated life-test has started and further design optimization are underway.
Blood oxygenation and flow measurements using a single 720-nm tunable V-cavity laser.
Feng, Yafei; Deng, Haoyu; Chen, Xin; He, Jian-Jun
2017-08-01
We propose and demonstrate a single-laser-based sensing method for measuring both blood oxygenation and microvascular blood flow. Based on the optimal wavelength range found from theoretical analysis on differential absorption based blood oxygenation measurement, we designed and fabricated a 720-nm-band wavelength tunable V-cavity laser. Without any grating or bandgap engineering, the laser has a wavelength tuning range of 14.1 nm. By using the laser emitting at 710.3 nm and 724.4 nm to measure the oxygenation and blood flow, we experimentally demonstrate the proposed method.
Demonstration of miniaturized 20mW CW 280nm and 266nm solid-state UV laser sources
NASA Astrophysics Data System (ADS)
Landru, Nicolas; Georges, Thierry; Beaurepaire, Julien; Le Guen, Bruno; Le Bail, Guy
2015-02-01
Visible 561 nm and 532 nm laser emissions from 14-mm long DPSS monolithic cavities are frequency converted to deep UV 280 nm and 266 nm in 16-mm long monolithic external cavities. Wavelength conversion is fully insensitive to mechanical vibrations and the whole UV laser sources fit in a miniaturized housing. More than 20 mW deep UV laser emission is demonstrated with high power stability, low noise and good beam quality. Aging tests are in progress but long lifetimes are expected thanks to the cavity design. Protein detection and deep UV resonant Raman spectroscopy are applications that could benefit from these laser sources.
Tanghetti Md, Emil; Jennings, John
2018-01-01
This study was performed to better understand the cutaneous effects of using a fractional picosecond laser at 755 nm with a diffractive lens array and a picosecond Nd:YAG laser at 532 mn and 1064 nm with a holographic optic. We characterized the injuries created by these devices on skin clinically and histologically over 24 hours. With this information we modeled the effects of these devices on a cutaneous target. Eight patients, representing Fitzpatrick skin types I-VI, were treated on their backs with a picosecond Alexandrite laser with a diffractive lens array, as well as a picosecond Nd:YAG laser at 532 nm and 1064 nm with a holographic optic. Photographs were taken 15 minutes and 24 hours after treatments. Punch biopsies were obtained at 24 hours and examined histologically. Treatment with the picosecond Nd:YAG laser at both 532 nm and 1064 nm with the holographic optic revealed erythema and small scatted areas of petechial hemorrhage areas immediately and in many cases at 24 hours after treatment. The 755 nm picosecond Alexandrite laser with diffractive lens array produced erythema immediately after treatment, which largely dissipated 24 hours later. Histologies revealed intra-epidermal vacuoles with all three wavelengths. Fractional picosecond Nd:YAG laser at 532 nm and 1064 nm with the holographic optic showed focal areas of dermal and intra-epidermal hemorrhage with areas of vascular damage in some patients. This study demonstrates that both fractional picosecond devices produce vacuoles in the skin, which are most likely due to areas of laser induced optical breakdown (LIOB). In the patients (skin type II-IV) we observed scatter areas of hemorrhage in the skin, due to vascular damage with the 532 nm and 1064 nm, but not with 755 nm wavelengths. Lasers Surg. Med. 50:37-44, 2018. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.
885-nm Pumped Ceramic Nd:YAG Master Oscillator Power Amplifier Laser System
NASA Technical Reports Server (NTRS)
Yu, Anthony
2012-01-01
The performance of a traditional diode pumped solid-state laser that is typically pumped with 808-nm laser diode array (LDA) and crystalline Nd:YAG was improved by using 885-nm LDAs and ceramic Nd:YAG. The advantage is lower quantum defect, which will improve the thermal loading on laser gain medium, resulting in a higher-performance laser. The use of ceramic Nd:YAG allows a higher Nd dopant level that will make up the lower absorption at the 885-nm wavelength on Nd:YAG. When compared to traditional 808-nm pump, 885-nm diodes will have 30% less thermal load (or wasted heat) and will thus see a similar percentage improvement in the overall laser efficiency. In order to provide a more efficient laser system for future flight missions that require the use of low-repetition- rate (
Three color laser fluorometer for studies of phytoplankton fluorescence
NASA Technical Reports Server (NTRS)
Phinney, David A.; Yentsch, C. S.; Rohrer, J.
1988-01-01
A three-color laser fluorometer has been developed for field work operations. Using two tunable dye lasers (excitation wavelengths at 440 nm and 530 nm), broadband wavelength optical filters were selected to obtain maximum fluorescence sensitivity at wavelengths greater than 675 nm (chlorophyll) and 575 + or - 15 nm (phycoerythrin). The laser fluorometer permits the measurement of phytoplankton pigments under static or flowing conditions and more closely resembles the time scales (ns) and energy levels (mW) of other laser-induced fluorescence instruments.
Compact dual-wavelength Nd:GdVO4 laser working at 1063 and 1065 nm.
Wu, Bo; Jiang, Peipei; Yang, Dingzhong; Chen, Tao; Kong, Jian; Shen, Yonghang
2009-04-13
We report a compact diode-laser pumped Nd:GdVO(4) laser with stable dual-wavelength output at 1063 nm and 1065 nm simultaneously. Two types of resonant cavity configurations were presented to support the stable dual-wavelength operation of the laser. Using a polarization beam splitter(PBS) included T-shaped cavity, we obtained a total power output over 5 W in two orthogonal polarized beam directions with 4 W in sigma polarization (1065.5 nm) and 1 W in pi polarization (1063.1 nm). By combining a half-wave-plate with the PBS in the laser cavity, a new configuration favoring one beam direction dual-wavelength output with same polarization direction was realized. A phenomenon of further line splitting was observed in both 1065 nm and 1063 nm.
Soliton self-frequency shift controlled by a weak seed laser in tellurite photonic crystal fibers.
Liu, Lai; Meng, Xiangwei; Yin, Feixiang; Liao, Meisong; Zhao, Dan; Qin, Guanshi; Ohishi, Yasutake; Qin, Weiping
2013-08-01
We report the first demonstration of soliton self-frequency shift (SSFS) controlled by a weak continuous-wave (CW) laser, from a tellurite photonic crystal fiber pumped by a 1560 nm femtosecond fiber laser. The control of SSFS is performed by the cross-gain modulation of the 1560 nm femtosecond laser. By varying the input power of the weak CW laser (1560 nm) from 0 to 1.17 mW, the soliton generated in the tellurite photonic crystal fiber blue shifts from 1935 to 1591 nm. The dependence of the soliton wavelength on the operation wavelength of the weak CW laser is also measured. The results show the CW laser with a wavelength tunable range of 1530-1592 nm can be used to control the SSFS generation.
Efficient blue emission of ytterbium-doped Sr5(PO4)3F under quasi-three-level intracavity pumping
NASA Astrophysics Data System (ADS)
Yang, Y.; Cao, G. H.
2012-02-01
We report an Yb:Sr5(PO4)3F (Yb:S-FAP) laser emitting at 985 nm intracavity pumped by a 912 nm diode-pumped Nd:GdVO4 laser. A 808 nm diode laser is used to pump the Nd:GdVO4 crystal emitting at 912 nm, and the Yb:S-FAP laser emitting at 985 nm intracavity pumped at 912 nm. With incident pump power of 17.5 W, intracavity second harmonic generation has been demonstrated with a power of 131 mW at 492.5 nm by using a LBO nonlinear crystal.
Formation of surface nanolayers in chalcogenide crystals using coherent laser beams
NASA Astrophysics Data System (ADS)
Ozga, K.; Fedorchuk, A. O.; El-Naggar, A. M.; Albassam, A. A.; Kityk, V.
2018-03-01
We have shown a possibility to form laser modified surface nanolayers with thickness up to 60 nm in some ternary chalcogenide crystals (Ag3AsS3, Ag3SbS3, Tl3SbS3) The laser treatment was performed by two coherent laser beams split in a space. As the inducing lasers we have applied continuous wave (cw) Hesbnd Cd laser at wavelength 441 nm and doubled frequency cw Nd: YAG laser at 532 nm. The spectral energies of these lasers were higher with respect to the energy gaps of the studied crystals. The optical anisotropy was appeared and defected by monitoring of birefringence at probing wavelength of cw Hesbnd Ne laser at λ = 3390 nm. The changes of the laser stimulated near the surface layer morphology was monitored by TEM and AFM methods as well as by the reflected optical second harmonic generation at fundamental wavelength of microsecond CO2 laser generating at wavelength 10600 nm. This technique may open a new approach for the formation of the near the surface nanolayers in chalcogenides using external cw laser illumination.
NASA Technical Reports Server (NTRS)
Chen, Songsheng; Storm, Mark E.; Marsh, Waverly D.; Petway, Larry B.; Edwards, William C.; Barnes, James C.
2000-01-01
A compact and high-pulse-energy Ti:Sapphire laser with its Third Harmonic Generation (THG) has been developed for an airborne ozone differential absorption lidar (DIAL) to study the distributions and concentrations of the ozone throughout the troposphere. The Ti:Sapphire laser, pumped by a frequency-doubled Nd:YAG laser and seeded by a single mode diode laser, is operated either at 867 nm or at 900 nm with a pulse repetition frequency of 20 Hz. High energy laser pulses (more than 110 mJ/pulse) at 867 nm or 900 nm with a desired beam quality have been achieved and utilized to generate its third harmonic at 289nm or 300nm, which are on-line and off-line wavelengths of an airborne ozone DIAL. After being experimentally compared with Beta-Barium Borate (beta - BaB2O4 or BBO) nonlinear crystals, two Lithium Triborate (LBO) crystals (5 x 5 x 20 cu mm) are selected for the Third Harmonic Generation (THG). In this paper, we report the Ti:Sapphire laser at 900 nm and its third harmonic at 300 nm. The desired high ultraviolet (UV) output pulse energy is more than 30 mJ at 300 nm and the energy conversion efficiency from 900 nm to 300 nm is 30%.
NASA Astrophysics Data System (ADS)
Chen, Shih-Yang; He, Yulu; Hsieh, Cheng-Che; Hua, Wei-Hsiang; Low, Meng Chun; Tsai, Meng-Tsan; Kiang, Yean-Woei; Yang, Chih-Chung
2017-02-01
The use of a high-resolution optical coherence tomography (OCT) system with the operation wavelength around 800 nm to scan SCC4 cancer cells under different laser illumination conditions is demonstrated. The cancer cells are incubated with Au nanorings (NRIs), which are linked with photosensitizer, AlPcS, for them to be up-taken by the cells. Two Au NRI samples of different geometries for inducing localized surface plasmon (LSP) resonance around 1310 and 1064 nm are used. Four different lasers are utilized for illuminating the cells under OCT scanning, including 1310-nm continuous (cw) laser, 1064-nm cw laser, 1064-nm femtosecond (fs) laser, and 660-nm cw laser. The 1310- and 1064-nm cw lasers mainly produce the photothermal effect through the LSP resonance of Au NRIs for damaging the observed cells. Besides the photothermal effect, the 1064-nm fs laser can produce strong two-photon absorption through the assistance of the LSP resonance of Au NRI for exciting AlPcS to effectively generate singlet oxygen and damage the observed cells. The 660-nm laser can excite AlPcS through single-photon absorption for generating singlet oxygen and damaging the observed cells. With the photothermal effect, the observed cells can be killed through the process of necrosis. Through the generation of singlet oxygen, the cell membrane can be preserved and the interior substances are solidified to become a hard body of strong scattering. In this situation, the cells are killed through the apoptosis process. Illuminated by the 660-nm cw laser, a process of interior substance escape is observed through high-speed OCT scanning.
Miniature solid-state lasers for pointing, illumination, and warning devices
NASA Astrophysics Data System (ADS)
Brown, D. C.; Singley, J. M.; Yager, E.; Kowalewski, K.; Lotito, B.; Guelzow, J.; Hildreth, J.; Kuper, J. W.
2008-04-01
In this paper we review the current status of and progress towards higher power and more wavelength diverse diode-pumped solid-state miniature lasers. Snake Creek Lasers now offers unprecedented continuous wave (CW) output power from 9.0 mm and 5.6 mm TO type packages, including the smallest green laser in the world, the MicroGreen TM laser, and the highest density green laser in the world, the MiniGreen TM laser. In addition we offer an infrared laser, the MiniIR TM, operating at 1064 nm, and have just introduced a blue Mini laser operating at 473 nm in a 9.0 mm package. Recently we demonstrated over 1 W of output power at 1064 nm from a 12 mm TO type package, and green output power from 300-500 mW from the same 12 mm package. In addition, the company is developing a number of other innovative new miniature CW solid-state lasers operating at 750 nm, 820 nm, 458 nm, and an eye-safe Q-switched laser operating at 1550 nm. We also review recently demonstrated combining volume Bragg grating (VBG) technology has been combined with automatic power control (APC) to produce high power MiniGreen TM lasers whose output is constant to +/- 10 % over a wide temperature range, without the use of a thermoelectric cooler (TEC). This technology is expected to find widespread application in military and commercial applications where wide temperature operation is particularly important. It has immediate applications in laser pointers, illuminators, and laser flashlights, and displays.
High-efficient Nd:YAG microchip laser for optical surface scanning
NASA Astrophysics Data System (ADS)
Šulc, Jan; Jelínková, Helena; Nejezchleb, Karel; Škoda, Václav
2017-12-01
A CW operating, compact, high-power, high-efficient diode pumped 1064nm laser, based on Nd:YAG active medium, was developed for optical surface scanning and mapping applications. To enhance the output beam quality, laser stability, and compactness, a microchip configuration was used. In this arrangement the resonator mirrors were deposited directly on to the laser crystal faces. The Nd-doping concentration was 1 at.% Nd/Y. The Nd:YAG crystal was 5mm long. The laser resonator without pumping radiation recuperation was investigated {the output coupler was transparent for pumping radiation. For the generated laser radiation the output coupler reflectivity was 95%@1064 nm. The diameter of the samples was 5 mm. For the laser pumping two arrangements were investigated. Firstly, a fibre coupled laser diode operating at wavelength 808nm was used in CW mode. The 400 ¹m fiber was delivering up to 14W of pump power amplitude to the microchip laser. The maximum CW output power of 7.2W @ 1064nm in close to TEM00 beam was obtained for incident pumping power 13.7W @ 808 nm. The differential efficiency in respect to the incident pump power reached 56 %. Secondly, a single-emitter, 1W laser diode operating at 808nm was used for Nd:YAG microchip pumping. The laser pumping was directly coupled into the microchip laser using free-space lens optics. Slope efficiency up to 70% was obtained in stable, high-quality, 1064nm laser beam with CW power up to 350mW. The system was successfully used for scanning of super-Gaussian laser mirrors reflectivity profile.
Green fiber lasers: An alternative to traditional DPSS green lasers for flow cytometry
Telford, William G.; Babin, Sergey A.; Khorev, Serge V.; Rowe, Stephen H.
2009-01-01
Green and yellow diode-pumped solid state (DPSS) lasers (532 and 561 nm) have become common fixtures on flow cytometers, due to their efficient excitation of phycoerythrin (PE) and its tandems, and their ability to excite an expanding array of expressible red fluorescent proteins. Nevertheless, they have some disadvantages. DPSS 532 nm lasers emit very close to the fluorescein bandwidth, necessitating optical modifications to permit detection of fluorescein and GFP. DPSS 561 nm lasers likewise emit very close to the PE detection bandwidth, and also cause unwanted excitation of APC and its tandems, requiring high levels of crossbeam compensation to reduce spectral overlap into the PE tandems. In this paper, we report the development of a new generation of green fiber lasers that can be engineered to emit in the range between 532 and 561 nm. A 550 nm green fiber laser was integrated into both a BD LSR II™ cuvette and FACSVantage DiVa™ jet-in-air cell sorter. This laser wavelength avoided both the fluorescein and PE bandwidths, and provided better excitation of PE and the red fluorescent proteins DsRed and dTomato than a power-matched 532 nm source. Excitation at 550 nm also caused less incidental excitation of APC and its tandems, reducing the need for crossbeam compensation. Excitation in the 550 nm range therefore proved to be a good compromise between 532 and 561 nm sources. Fiber laser technology is therefore providing the flexibility necessary for precisely matching laser wavelengths to our flow cytometry applications. PMID:19777600
Electro-optically Q-switched dual-wavelength Nd:YLF laser emitting at 1047 nm and 1053 nm
NASA Astrophysics Data System (ADS)
Men, Shaojie; Liu, Zhaojun; Cong, Zhenhua; Li, Yongfu; Zhang, Xingyu
2015-05-01
A flash-lamp pumped electro-optically Q-switched dual-wavelength Nd:YLF laser is demonstrated. Two Nd:YLF crystals placed in two cavities are employed to generate orthogonally polarized 1047 nm and 1053 nm radiations, respectively. The two cavities are jointed together by a polarizer and share the same electro-optical Q-switch. Two narrow-band pass filters are used to block unexpected oscillations at the hold-off state of the electro-optical Q-switch. In this case, electro-optical Q-switching is able to operate successfully. With pulse synchronization realized, the maximum output energy of 66.2 mJ and 83.9 mJ are obtained for 1047 nm and 1053 nm lasers, respectively. Correspondingly, the minimum pulse width is both 17 ns for 1047 nm and 1053 nm lasers. Sum frequency generation is realized. This demonstrates the potential of this laser in difference-frequency generations to obtain terahertz wave.
Efficient laser operation of Nd3+:Lu2O3 at various wavelengths between 917 nm and 1463 nm
NASA Astrophysics Data System (ADS)
von Brunn, P.; Heuer, A. M.; Fornasiero, L.; Huber, G.; Kränkel, C.
2016-08-01
Even though the first Nd3+-doped sesquioxide lasers have been realized more than 50 years ago, up to now no reports on efficient laser operation of Nd3+:doped sesquioxides can be found. In this work, we review the favorable spectroscopic properties of the sesquioxide Nd3+:Lu2O3 in terms of ground state absorption, stimulated emission, and excited state absorption cross sections as well as the upper level lifetime. Making use of these properties, we achieved efficient laser performance on eight different laser transitions in the wavelength range between 917 nm and 1463 nm under Ti:sapphire laser pumping using state-of-the-art HEM-grown Nd3+:Lu2O3 crystals with good optical quality. At the strongest transition around 1076 nm we determined a slope efficiency of 69%, which represents the highest efficiency ever obtained for a Nd3+-doped sesquioxide. Furthermore, we could generate watt level output powers and high slope efficiencies for seven other transitions. Lasers at 917 nm, 1053 nm, 1108 nm and 1463 nm were realized for the first time and the latter represents one of the longest laser wavelengths obtained on the 4F3/2 → 4I13/2 transition in Nd3+-doped materials.
Compact gain saturated plasma based X-ray lasers down to 6.9nm
NASA Astrophysics Data System (ADS)
Rocca, Jorge; Wang, Y.; Wang, S.; Rockwood, A.; Berrill, M.; Shlyaptsev, V.
2017-10-01
Plasma based soft x-ray amplifiers allow many experiments requiring bright, high energy soft x-ray laser pulses to be conducted in compact facilities. We have extended the wavelength of compact gain saturated x-ray lasers to 6.89 nm in a Ni-like Gd plasma generated by a Ti:Sa laser. Gain saturated laser operation was also obtained at 7.36 nm in Ni-like Sm. Isolectronic scaling and optimization of laser pre-pulse duration allowed us to also observe strong lasing at 6.6 nm and 6.1 nm in Ni-like Tb, and amplification at 6.4 nm and 5.89 nm in Ni-like Dy. The results were obtained by transient laser heating of solid targets with traveling wave excitation at progressively increased gracing incidence angles. We show that the optimum pump angle of incidence for collisional Ni-like lasers increases linearly with atomic number from Z =42 to Z =66, reaching 43 degrees for Ni-like Dy, in good agreement with hydrodynamic/atomic physics simulations. These results will enable single-shot nano-scale imaging and other application of sub-7 nm lasers to be performed at compact facilities. Work supported by Grant DE-FG02-4ER15592 of the Department of Energy, Office of Science, and by the National Science Foundation Grant ECCS 1509925.
Effect of a 308-nm excimer laser on atopic dermatitis-like skin lesions in NC/Nga mice.
Oh, Chang Taek; Kwon, Tae-Rin; Seok, Joon; Choi, Eun Ja; Kim, Soon Re; Jang, Yu-Jin; Mun, Seog Kyun; Kim, Chan Woong; Lee, Sungeun; Lee, Jongmin; Kim, Myeung Nam; Choi, Sun Young; Kim, Beom Joon
2016-08-01
Atopic dermatitis (AD) is a common inflammatory skin disease that can affect all age groups. It has a relapsing course, which dramatically affects the quality of life of patients. A 308-nm excimer laser has been reported to be a safe and effective treatment for inflammatory skin diseases, although the range of potential application has not been fully explored. The purpose of this study was to evaluate the therapeutic effects of a 308-nm laser on AD-like skin lesions in NC/Nga mice. Dermatophagoides farinae-exposed NC/Nga mice with a clinical score of 12 were treated with either a 308-nm excimer laser or narrowband-UVB (NB-UVB). The effects of the 308-nm excimer laser were evaluated by dermatitis scores, skin histology, skin barrier function, and immunological parameters, including IgE and Th2-mediated cytokines. The 308-nm excimer laser significantly reduced the severity of skin lesions and decreased the total serum levels of IgE and Th2-mediated cytokines. The excimer laser also significantly reduced the inflammatory cellular infiltrate into AD-induced skin lesions. Moreover, treatment with the 308-nm excimer laser led to recovery of skin barrier function in AD-induced skin lesions. The 308-nm excimer laser can be considered a valid and safe therapeutic option for the treatment of localized AD. Lasers Surg. Med. 48:629-637, 2016. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.
Continuous 1052, 1064 nm dual-wavelength Nd:YAG laser
NASA Astrophysics Data System (ADS)
Wang, Xiaozhong; Yuan, Haiyang; Wang, Mingshan; Huang, Wencai
2016-10-01
Dual-wavelength lasers are usually obtained through balancing the net gain of the two oscillating lines. Competition between transitions 1052 nm, 1061 nm and 1064 nm is utilized to realize a continuous wave 1052 and 1064 nm dual-wavelength Nd:YAG laser firstly in this paper. A specially designed Fabry-Perot band-pass filter is exploited as output coupler to control the thresholds of the oscillating wavelengths. The maximum power of the dual-wavelength laser is 1.6 W and the slope efficiency is about 10%. The power instability of the output dual-wavelength laser is smaller than ±4% in half an hour. The mechanism presented in this paper may provide a new way to obtain dual-wavelength lasers.
Diode-pumped Nd:GAGG-LBO laser at 531 nm
NASA Astrophysics Data System (ADS)
Zou, J.; Chu, H.; Wang, L. R.
2012-03-01
We report a green laser at 531 nm generation by intracavity frequency doubling of a continuous wave (cw) laser operation of a 1062 nm Nd:GAGG laser under in-band diode pumping at 808 nm. A LiB3O5 (LBO) crystal, cut for critical type I phase matching at room temperature is used for second harmonic generation of the laser. At an incident pump power of 18.5 W, as high as 933 mW of cw output power at 531 nm is achieved. The fluctuation of the green output power was better than 3.5% in the given 4 h.
NASA Astrophysics Data System (ADS)
Piasecki, M.; Myronchuk, G. L.; Parasyuk, O. V.; Khyzhun, O. Y.; Fedorchuk, A. O.; Pavlyuk, V. V.; Kozer, V. R.; Sachanyuk, V. P.; El-Naggar, A. M.; Albassam, A. A.; Jedryka, J.; Kityk, I. V.
2017-02-01
For the first time phase equilibria and phase diagram of the AgGaS2-SiS2 system were successfully explored by differential thermal and X-ray phase analysis methods. Crystal structure of low-temperature (LT) modification of Ag2Ga2SiS6 (LT- Ag2Ga2SiS6) was studied by X-ray powder method and it belongs to tetragonal space group I-42d, with unit cell parameters a=5.7164(4) Å, c=9.8023(7) Å, V=320.32(7) Å3. Additional details regarding the crystal structure exploration are available at the web page Fachinformationszentrum Karlsruhe. X-ray photoelectron core-level and valence-band spectra were measured for pristine LT- Ag2Ga2SiS6 crystal surface. In addition, the X-ray photoelectron valence-band spectrum of LT-Ag2Ga2SiS6 was matched on a common energy scale with the X-ray emission S Kβ1,3 and Ga Kβ2 bands, which give information on the energy distribution of the S 3p and Ga 4p states, respectively. The presented X-ray spectroscopy results indicate that the valence S p and Ga p atomic states contribute mainly to the upper and central parts of the valence band of LT-Ag2Ga2SiS6, respectively, with a less significant contribution also to other valence-band regions. Band gap energy was estimated by measuring the quantum energy in the spectral range of the fundamental absorption. We have found that energy gap Eg is equal to 2.35 eV at 300 K. LT-Ag2Ga2SiS6 is a photosensitive material and reveals two spectral maxima on the curve of spectral photoconductivity spectra at λmax1 =590 nm and λmax2 =860 nm. Additionally, linear electro-optical effect of LT-Ag2Ga2SiS6 for the wavelengths of a cw He-Ne laser at 1150 nm was explored.
Krupke, William F.; Payne, Stephen A.; Marshall, Christopher D.
2001-01-01
The invention provides an efficient, compact means of generating blue laser light at a wavelength near .about.493+/-3 nm, based on the use of a laser diode-pumped Yb-doped laser crystal emitting on its zero phonon line (ZPL) resonance transition at a wavelength near .about.986+/-6 nm, whose fundamental infrared output radiation is harmonically doubled into the blue spectral region. The invention is applied to the excitation of biofluorescent dyes (in the .about.490-496 nm spectral region) utilized in flow cytometry, immunoassay, DNA sequencing, and other biofluorescence instruments. The preferred host crystals have strong ZPL fluorecence (laser) transitions lying in the spectral range from .about.980 to .about.992 nm (so that when frequency-doubled, they produce output radiation in the spectral range from 490 to 496 nm). Alternate preferred Yb doped tungstate crystals, such as Yb:KY(WO.sub.4).sub.2, may be configured to lase on the resonant ZPL transition near 981 nm (in lieu of the normal 1025 nm transition). The laser light is then doubled in the blue at 490.5 nm.
Wang, Xiaojie; Wang, Xiaolei; Zheng, Zhifen; Qiao, Xihao; Dong, Jun
2018-04-20
A synchronous pulsed, dual-wavelength Raman laser at 1164.4 nm and 1174.7 nm has been demonstrated in a Nd:GdVO 4 /Cr 4+ :YAG/YVO 4 passively Q-switched Raman microchip laser (PQSRML). The 1164.4 nm and 1174.7 nm dual-wavelength first-order Stokes laser oscillation is attributed to the conversion of the 1063.2 nm and 1063.43 nm two-longitudinal-mode fundamental lasers with Raman frequency shifts of 816 cm -1 and 890 cm -1 , respectively. Stable dual-wavelength Raman laser pulses with nearly equal spectral intensities have been achieved independent of the pump power. A pulse repetition rate as high as 139.4 kHz has been achieved with T 0 =85%, and the pulse width has been shortened to 825 ps with T 0 =70%. A dual-wavelength Raman laser with sub-nanosecond pulse width and peak power of over 1 kW has been achieved in the Nd:GdVO 4 /Cr 4+ :YAG/YVO 4 PQSRML.
Large laser projection displays utilizing all-solid-state RGB lasers
NASA Astrophysics Data System (ADS)
Xu, Zuyan; Bi, Yong
2005-01-01
RGB lasers projection displays have the advantages of producing large color triangle, high color saturation and high image resolution. In this report, with more than 4W white light synthesized by red (671nm), green (532nm) and blue (473nm) lasers, a RGB laser projection display system based on diode pumped solid-state lasers is developed and the performance of brilliant and vivid DVD dynamitic pictures on 60 inch screen is demonstrated.
Xuan, Hongwen; Zhao, Zhigang; Igarashi, Hironori; Ito, Shinji; Kakizaki, Kouji; Kobayashi, Yohei
2015-04-20
A narrow-linewidth, high average power deep-ultraviolet (DUV) coherent laser emitting at 193 nm is demonstrated by frequency mixing a Yb-hybrid laser with an Er-fiber laser. The Yb-hybrid laser consists of Yb-fiber lasers and an Yb:YAG amplifier. The average output power of the 193 nm laser is 310 mW at 6 kHz, which corresponds to a pulse energy of 51 μJ. To the best of our knowledge, this is the highest average power and pulse energy ever reported for a narrow-linewidth 193 nm light generated by a combination of solid-state and fiber lasers with frequency mixing. We believe this laser will be beneficial for the application of interference lithography by seeding an injection-locking ArF eximer laser.
NASA Astrophysics Data System (ADS)
Li, B.; Zhao, L.; Zhang, Y. B.; Zheng, Q.; Zhao, Y.; Yao, Y.
2013-03-01
Efficient and compact green-yellow laser output at 543 nm is generated by intracavity frequency doubling of a CW diode-pumped Nd:LuVO4 laser at 1086 nm under the condition of suppressing the higher gain transition near 1064 nm. With 16 W of diode pump power and the frequency-doubling crystal LBO, as high as 2.17 W of CW output power at 543 nm is achieved, corresponding to an optical-to-optical conversion efficiency of 13.6% and the output power stability over 8 hours is better than 2.86%. To the best of our knowledge, this is the highest watt-level laser at 543 nm generated by intracavity frequency doubling of a diode pumped Nd:LuVO4 laser at 1086 nm.
Havel, Miriam; Sroka, Ronald; Englert, Elsa; Stelter, Klaus; Leunig, Andreas; Betz, Christian S
2012-09-01
The need for reduction of post-tonsillectomy hemorrhage has led to promotion of tonsillotomy techniques for tonsil tissue reduction in obstructive tonsillar hypertrophy. This trial compares ablative tissue effects using 1,470 nm diode laser and carbon dioxide laser for tonsillotomy in an intraindividual design. 21 children aged 3-13 years (mean age 6.3 years) underwent laser tonsillotomy for obstructive tonsillar hypertrophy in this double blind, prospective, randomized, clinical feasibility trial. In each of the blinded patients, tonsillotomy was performed using fiber guided 1,470 nm diode laser (contact mode, 15 W power) on the one side and carbon dioxide laser (12 W power) on the other side. An independent, blinded physician documented clinical presentation and patients' symptoms preoperatively and on Days 1, 3, 7, 14, and 21 post-operatively using standardized questionnaire including VAS for each side separately. The mean duration of operative treatment was 2.7 min using 1,470 nm laser and 4.9 min using carbon dioxide laser respectively. Intraoperative bleeding and the frequency of bipolar forceps use for intraoperative bleeding control was significantly less using 1,470 nm diode laser system. There was no difference in post-operative pain scores between the carbon dioxide laser treated and the 1,470 nm fiber guided diode laser treated side. No infections, hemorrhages or other complications occurred in the course of the 3 weeks post-operative period. A fiber-guided 1,470 nm diode laser system offers an efficient and safe method for tonsillotomy as treatment of obstructive tonsillar hypertrophy. Compared to our standard practice (carbon dioxide laser), 1,470 nm laser application provides comparable tissue ablation effects with less intraoperative bleeding and shorter operation time. Copyright © 2012 Wiley Periodicals, Inc.
Test of VPHGS in SHSG for use at cryogenic temperatures
NASA Astrophysics Data System (ADS)
Insaustia, Maider; Garzón, Francisco; Mas-Abellán, P.; Madrigal, R.; Fimia, A.
2017-05-01
Silver halide sensitized gelatin (SHSG) processes are interesting because they combine the spectral and energetic sensitivity of a photographic emulsions with good optical quality and high diffraction efficiency of dichromate gelatin (DCG). Previous papers had been demonstrated that it is possible to obtain diffraction efficiencies near to 90% with Agfa- Gevaert plates and Colour Holographic plates in SHSG transmission gratings. In this communication, we report on the performances measured at room temperature and in cryogenic conditions of a set of volume phase holographic gratings(VPHGs) manufactured with SHSG process aimed at their use in astronomical instrumentations. Two set of diffraction gratings has been manufactured using different processing. The first with SHSG process and the second with typical bleached process (developed with AAC and bleached in R-10). In both cases the plate was BB640, ultrafine grain emulsions with a nominal thickness of 9 μm. The recording was performed with asymmetric geometry a 30° degrees between the light beams of wavelength 632.8 nm (He-Ne laser), which give a raise a spectral frequency of 800 l/m. The exposure was between 46 to 2048 μJ/cm2. The results give us information about Bragg plane modification and reduction of diffraction efficiency when we introduced the VPHG to 77° K. In the case of SHSG process the final diffraction efficiency after cryogenic temperature are better at some exposure energy than previous measurements at room temperature. This experimental result give us possibilities to applied SHSG process in Astrophysics applications.
Intense excitation source of blue-green laser
NASA Astrophysics Data System (ADS)
Han, Kwang S.
1986-10-01
An intense and efficient source for blue green laser useful for the space-based satellite laser applications, underwater strategic communication, and measurement of ocean bottom profile is being developed. The source in use, the hypocycloidal pinch plasma (HCP), and the dense plasma focus (DPF) can produce intense uv photons (200 to 400nm) which match the absorption spectra of both near UV and blue green dye lasers (300 to 400nm). As a result of optimization of the DPF light at 355nm, the blue green dye (LD490) laser output exceeding 4mJ was obtained at the best cavity tunning of the laser system. With the HCP pumped system a significant enhancement of the blue green laser outputs with dye LD490 and coumarin 503 has been achieved through the spectrum conversion of the pumping light by mixing a converter dye BBQ. The maximum increase of laser output with the dye mixture of LD490+BBQ and coumarin 503+BBQ was greater than 80%. In addition, the untunned near UV lasers were also obtained. The near UV laser output energy of P-terphenyl dye was 0.5mJ at lambda sub C=337nm with the bandwidth of 3n m for the pulse duration of 0.2us. Another near UV laser output energy obtained with BBQ dye was 25 mJ at lambda sub C=383nm with the bandwidth of 3nm for the pulse duration of 0.2us. Another near UV laser output energy obtained with BBQ dye was 25 mJ at lambda sub C=383nm with the bandwidth of 3nm for the pulse duration of 0.2microsec.
NASA Technical Reports Server (NTRS)
Miller, George E.
1992-01-01
Differential absorption of laser radiation by various molecular species represents both a selective and a sensitive method of measuring specific atmospheric constituents. DIAL measurements can be carried out via two different means. Both involve using two laser pulses with slightly different wavelengths (lambda), (one lambda at a strong absorption line of the molecule of interest, the other detuned into the wing of the line), and comparing the attenuation of the pulses. One approach relies on scattering of the radiation from some conveniently located topographical target. In the other technique elastic scattering from atmospheric aerosols and particulates is used to return the radiation to the lidar receiver system. This case is referred to as the differential absorption and scattering technique, and is the technique we are interested in to measure water vapor at 940 nm. The 940 nm wavelength is extremely desirable to atmospheric scientist interested in accurate DIAL measurements of H2O in the upper and lower troposphere. Simulated measurements using approximately 940 nm and 815 nm lasers at a range of altitudes and experimental conditions are shown. By offering access to larger absorption cross-sections, injected seeded, 940 nm DIAL laser transmitters would allow for more accurate water profile measurements at altitudes from 6 to 16 km than is currently possible with 730 nm and 815 nm DIAL laser transmitters. We have demonstrated the operation of an injected seeded titanium-sapphire (TS) laser operating at approximately 940 nm with an energy of more than 90 mJ per pulse. The TS laser is pumped by a commercial, 600 mJ, 532 nm, 10 Hz Nd:YAG laser. The slope efficiency of the laser using a flat 50 percent R output coupler and a 10 m end-mirror is shown. The laser was injected seeded with a CW, AlGaAs, semiconductor diode laser which had an output of 83 mW. The CW diode seed beam was introduced into the TS laser cavity through a HR end-mirror. When the diode beam is aligned to the TS resonator, it controls the TS laser output wavelength and its spectral line width with the required resolution for DIAL applications. This work supports the need for the development of 940 nm, titanium-sapphire DIAL transmitters.
Applications of the Excimer Laser: A Review.
Beggs, Sarah; Short, Jack; Rengifo-Pardo, Monica; Ehrlich, Alison
2015-11-01
The 308-nm excimer laser has been approved by the Food and Drug Administration for the treatment of psoriasis and vitiligo. Its ability to treat localized areas has led to many studies determining its potential in the treatment of focal diseases with inflammation or hypopigmentation. To review the different applications of the 308-nm excimer laser for treating dermatologic conditions. An extensive literature review was conducted by searching PubMed, MEDLINE, and ClinicalKey to find articles pertaining to dermatologic conditions treated with the 308-nm excimer laser. Articles published that contributed to new applications of the excimer laser were included, as well as initial studies utilizing the excimer laser. The outcomes and results were compiled for different dermatologic conditions treated with the excimer laser. The 308-nm excimer laser has a wide range of uses for focal inflammatory and hypopigmented conditions. Treatment is generally well tolerated, with few adverse reactions. Larger studies and studies evaluating the long-term effects of the 308-nm excimer laser are needed.
Photolasertherapy for the treatment of infections in neurosurgery: experimental and clinical study
NASA Astrophysics Data System (ADS)
Lombard, Gian F.
1996-12-01
At the first time, the CO2 laser was utilised in infective neurosurgical pathology as a surgical cutting instrument to remove inflammatory pseudomembranes in chronic osteomyelitis, and as a vaporising instmment on the dura mater surface. Successively, the instrument, defocused and at a low power, was used for prolonged and diffuse photo coagulation ofthe surgical cavity, particularly, ofthe dural surface and ofthe osteomyelitic bone edges, with the aim to sterilise tissues. So, we saw a shortening of the average time of wound healing and a lack of recurrence of the septic pathology. Then, we have treated, with CO2 laser, intracranial infective pathology: i.e. primary abscesses, capsulated or not, circumscribed purulent encephalitis, secondary abscesses in surgical cavities (patients operated for intracranial hematomas and tumors). In these cases we have obtained a lack of septic recurrences and an improvement ofneurological post-operative course. Thank to these results, we have continued to use laser in infective pathology; for giving an experimental support to these results we have carried on researches in vivo (on the experimental animal) to see the interaction between the laser and inflammatory tissue, and in vitro (on bacterial culture: in solid and liquid media) to see the laser effect on the bacterial cell. The bacterial cell has been also sensibiized to the photo dynamic effect of the laser (Argon, He-Ne), with hematoporphyrin. The goal of these experiments is to understand the role of thermal, photochemical, and mechanic resonance laser effects in the interaction between laser radiation and bacterial cell.
New 223-nm excimer laser surgical system for photorefractive keratectomy
NASA Astrophysics Data System (ADS)
Bagaev, Sergei N.; Razhev, Alexander M.; Zhupikov, Andrey A.
1999-02-01
The using of KrCl (223 nm) excimer laser in ophthalmic devices for Photorefractive Keratectomy (PRK) and phototherapeutic Keratectomy (PTK) is offered. The structure and functions of a new surgical UV ophthalmic laser systems Medilex using ArF (193 nm) or KrCl (223 nm) excimer laser for corneal surgery are presented. The systems Medilex with the new optical delivery system is used for photoablative reprofiling of the cornea to correct refraction errors (myopia, hyperopia and astigmatism) and to treat a corneal pathologies. The use of the 223 nanometer laser is proposed to have advantages over the 193 nanometer laser. The results of application of the ophthalmic excimer laser systems Medilex for treatment of myopia are presented.
Nie, Weijie; Cheng, Chen; Jia, Yuechen; Romero, Carolina; Vázquez de Aldana, Javier R; Chen, Feng
2015-05-15
Low-loss depressed cladding waveguides have been produced in Nd:YAP laser crystal by using direct femtosecond laser writing. Under optical pump at 812 nm at room temperature, continuous-wave simultaneous dual-wavelength laser oscillations at 1064 and 1079 nm, both along TM polarization, have been realized in the waveguiding structures. It has been found that, with the variation of pump polarization, the intensity ratio of 1064 and 1079 nm emissions varies periodically, while the polarization of output dual-wavelength laser remains unchanged. The maximum output power achieved for the Nd:YAP waveguide lasers is ∼200 mW with a slope efficiency of 33.4%.
Optical response of laser-doped silicon carbide for an uncooled midwave infrared detector.
Lim, Geunsik; Manzur, Tariq; Kar, Aravinda
2011-06-10
An uncooled mid-wave infrared (MWIR) detector is developed by doping an n-type 4H-SiC with Ga using a laser doping technique. 4H-SiC is one of the polytypes of crystalline silicon carbide and a wide bandgap semiconductor. The dopant creates an energy level of 0.30 eV, which was confirmed by optical spectroscopy of the doped sample. This energy level corresponds to the MWIR wavelength of 4.21 μm. The detection mechanism is based on the photoexcitation of electrons by the photons of this wavelength absorbed in the semiconductor. This process modifies the electron density, which changes the refractive index, and, therefore, the reflectance of the semiconductor is also changed. The change in the reflectance, which is the optical response of the detector, can be measured remotely with a laser beam, such as a He-Ne laser. This capability of measuring the detector response remotely makes it a wireless detector. The variation of refractive index was calculated as a function of absorbed irradiance based on the reflectance data for the as-received and doped samples. A distinct change was observed for the refractive index of the doped sample, indicating that the detector is suitable for applications at the 4.21 μm wavelength.
NASA Astrophysics Data System (ADS)
Fallman, Erik G.; Schedin, Staffan; Andersson, Magnus J.; Jass, Jana; Axner, Ove
2003-06-01
Optical tweezers together with a position sensitive detection system allows measurements of forces in the pN range between micro-sized biological objects. A prototype force measurement system has been constructed around in inverted microscope with an argon-ion pumped Ti:sapphire laser as light source for optical trapping. A trapped particle in the focus of the high numerical aperture microscope-objective behaves like an omni-directional mechanical spring if an external force displaces it. The displacement from the equilibrium position is a measure of the exerted force. For position detection of the trapped particle (polystyrene beads), a He-Ne laser beam is focused a small distance below the trapping focus. An image of the bead appears as a distinct spot in the far field, monitored by a photosensitive detector. The position data is converted to a force measurement by a calibration procedure. The system has been used for measuring the binding forces between E-coli bacterial adhesin and their receptor sugars.
NASA Astrophysics Data System (ADS)
Aono, Masami; Harata, Tomo; Odawara, Taku; Asai, Shinnosuke; Orihara, Dai; Nogi, Masaya
2018-01-01
Amorphous carbon nitride (a-CN x ) thin films deposited by reactive sputtering have great potential for driving source applications of light-driven active devices. We demonstrate, for the first time, the photoinduced deformation of a-CN x deposited on flexible substrates, namely, poly(ethylene naphthalate) (PEN) films and transparent cellulose nanopaper. a-CN x films without delamination were obtained on both substrates. By decreasing the thickness of PEN films, the photoinduced deformation became extremely large. A light-driven pump was fabricated using a-CN x -coated PEN films, and then the pumping motion was observed up to 10 Hz. When a He-Ne laser traced the surface of a-CN x films deposited on the nanopaper, the sample moved to the opposite side of the laser spot. The motion involved repeated expansions and contractions similar to the motion of caterpillars occurring owing to the temporary photoinduced deformation of a-CN x films.
Temperature- and pressure-dependent absorption cross sections of gaseous hydrocarbons at 3.39 µm
NASA Astrophysics Data System (ADS)
Klingbeil, A. E.; Jeffries, J. B.; Hanson, R. K.
2006-07-01
The pressure- and temperature-dependent absorption cross sections of several neat hydrocarbons and multi-component fuels are measured using a 3.39 µm helium-neon laser. Absorption cross section measurements are reported for methane, ethylene, propane, n-heptane, iso-octane, n-decane, n-dodecane, JP-10, gasoline and jet-A with an estimated uncertainty of less than 3.5%. The experimental conditions range from 298 to 673 K and from 500 to 2000 Torr with nitrogen as the bath gas. An apparatus is designed to facilitate these measurements, and specific care is taken to ensure the compositional accuracy of the hydrocarbon/N2 mixtures. The absorption cross sections of the smallest hydrocarbons, methane and ethylene, vary with temperature and pressure. The cross sections of larger hydrocarbons show negligible dependence on pressure and only a weak dependence on temperature. The reported data increase the range of conditions and the number of hydrocarbons for which cross section measurements are available at the HeNe laser wavelength.
Holographic gunsights for small arms
NASA Astrophysics Data System (ADS)
Tai, Anthony M.; Sieczka, Eric J.; Radler, Richard; Upatnieks, Juris
1996-05-01
Holographic gunsights were first demonstrated in the mid 1970s by researchers at the Environmental Research Institute of Michigan (ERIM) under contracts with the Air Force and the Army. The sights utilized He-Ne gas lasers and were designed for use with large weapons systems. With the advent of low cost visible laser diode, ERIM formed a new company, EOTech, to develop, manufacture and market a holographic gun sight for small arms. A hologram is used to reconstruct the image of a reticle pattern that appears at the target plane. Unlike red-dot sights, virtually any reticle pattern, 2D or 3D, can be formed. The design challenges include an opto-mechanical package that is compact, light weight and low cost which can withstand recoils up to 4,000 Gs and provide fine elevation/windage pointing adjustments, and optics that are aberration-free and stable over a wide temperature range. Manufacturing challenges include the mass production of high quality holographic optics at low cost and the precision alignment of the very low f/number optics.
Levin, Melissa Kanchanapoomi; Ng, Elise; Bae, Yoon-Soo Cindy; Brauer, Jeremy A; Geronemus, Roy G
2016-02-01
Laser procedures in skin of color (SOC) patients are challenging due to the increased risk of dyspigmentation and scarring. A novel 755 nm alexandrite picosecond laser has demonstrated effectiveness for tattoo removal and treatment of acne scars. No studies to date have evaluated its applications in pigmentary disorders. The purpose of this retrospective study was to evaluate the safety profile and efficacy of the picosecond alexandrite laser compared to the current standard treatment, Q-switched ruby and neodynium (Nd):YAG nanosecond lasers, for pigmentary disorders in SOC patients. A retrospective photographic and chart evaluation of seventy 755 nm alexandrite picosecond, ninety-two Q-switched frequency doubled 532 nm and 1,064 nm Nd:YAG nanosecond, and forty-seven Q-switched 694 nm ruby nanosecond laser treatments, in forty-two subjects of Fitzpatrick skin types III-VI was conducted in a single laser specialty center. The picosecond laser was a research prototype device. Treatment efficacy was assessed by two blinded physician evaluators, using a visual analog scale for percentage of pigmentary clearance in standard photographs. Subject assessment of efficacy, satisfaction, and adverse events was performed using a questionnaire survey. The most common pigmentary disorder treated was Nevus of Ota (38.1%), followed by solar lentigines (23.8%). Other pigmentary disorders included post-inflammatory hyperpigmentation, congenital nevus, café au lait macule, dermal melanocytosis, Nevus of Ito, and Becker's nevus. Clinical efficacy of the Q-switched nanosecond lasers and picosecond laser treatments were comparable for lesions treated on the face with a mean visual analog score of 2.57 and 2.44, respectively, corresponding to approximately 50% pigmentary clearance. Subject questionnaires were completed in 58.8% of the picosecond subjects and 52.0% of the Q-switched subjects. Eighty four percent of subjects receiving Q-switched nanosecond laser treatments and 50% of the subjects receiving alexandrite 755 nm picosecond laser treatments felt satisfied to completely satisfied. Side effects observed in subjects treated with the alexandrite 755 nm picosecond laser were similar to those commonly observed and reported with the nanosecond Q-switched technology. All side effects were temporary, resolving within one month, and no long-term complications were noted. All patients who were very satisfied with their picosecond laser treatment for Nevus of Ota noted a delayed improvement only after 3 months. The 755 nm alexandrite picosecond, 694 nm ruby, 532 nm, and 1064 nm neodynium:YAG nanosecond lasers appear to be safe and effective modalities for removal of pigmentary disorders in skin of color patients with no long-term complications if used appropriately. This study demonstrates the potential of the 755 nm alexandrite picosecond laser in further clinical applications beyond tattoo removal. While the Q-switched lasers were effective, promising results were also observed using an early version of the novel picosecond laser for the removal of pigmentary lesions in SOC patients. As we continue to improve our understanding of the 755 nm picosecond laser, this device may prove to be a safe and effective alternative to the Q-switched lasers for the treatment of facial pigmented lesions in patients with skin of color. © 2016 Wiley Periodicals, Inc.
Vanaman Wilson, Monique J; Jones, Isabela T; Bolton, Joanna; Larsen, Lisa; Wu, Douglas C; Goldman, Mitchel P
2018-01-01
Infraorbital dark circles result from a combination of factors. The fractionated picosecond 755 nm alexandrite laser and dual wavelength picosecond Nd:YAG laser have not been examined as a method of addressing infraorbital hyperpigmentation. To determine the efficacy and safety of treatment of infraorbital dark circles using fractionated picosecond 755 nm and dual wavelength picosecond Nd:YAG laser. These trials did not utilize a comparative design; rather, these were separate, prospective, open-label, evaluator-blinded trials utilizing two treatment regimens: (i) 19 adult subjects were treated in a single session with the dual wavelengths of 532 nm and 1,064 nm in consecutive passes using the fractionated lens; (ii) 10 adult subjects were treated using the picosecond 755 nm laser via the fractionated lens in three treatment sessions at 3 week intervals. Subjects in both studies were followed-up for blinded-investigator assessment of infraorbital hyperpigmentation, adverse events, and improvement compared to baseline. The dual wavelength picosecond Nd:YAG laser, blinded-investigator assessment did not demonstrate a significant improvement in infraorbital hyperpigmentation at day 60 (P = 0.16). The picosecond 755 nm alexandrite laser significantly improved infraorbital hyperpigmentation by day 42, with improvement maintained through day 132 (P = 0.07 and 0.00001, respectively). Adverse events were mild and temporary. A single treatment with the fractionated picosecond 1,064/532 nm lasers did not produce a significant improvement in infraorbital hyperpigmentation. A series of three treatments with the fractionated picosecond 755 nm laser resulted in significant improvement in hyperpigmentation. Lasers Surg. Med. 50:45-50, 2018. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.
Three Hundred Patients Treated with Ultrapulsed 980 nm Diode Laser for Skin Disorders
Wollina, Uwe
2016-01-01
The use of lasers in skin diseases is quite common. In contrast to other laser types, medical literature about 980 nm ultrapulsed diode laser is sparse in dermatology. Herein, we report the use of ultrapulsed diode 980 nm laser in 300 patients with vascular lesions, cysts and pseudocysts, infectious disease, and malignant tumors. This laser is a versatile tool with excellent safety and efficacy in the hands of the experienced user. PMID:27688445
20 W continuous-wave cladding-pumped Nd-doped fiber laser at 910 nm.
Laroche, M; Cadier, B; Gilles, H; Girard, S; Lablonde, L; Robin, T
2013-08-15
We demonstrate a double-clad fiber laser operating at 910 nm with a record power of 20 W. Laser emission on the three-level scheme is enabled by the combination of a small inner cladding-to-core diameter ratio and a high brightness pump source at 808 nm. A laser conversion efficiency as high as 44% was achieved in CW operating regime by using resonant fiber Bragg reflectors at 910 nm that prevent the lasing at the 1060 nm competing wavelength. Furthermore, in a master oscillator power-amplifier scheme, an amplified power of 14.8 W was achieved at 914 nm in the same fiber.
Proposed SLR Optical Bench Required to Track Debris Using 1550 nm Lasers
NASA Technical Reports Server (NTRS)
Shappirio, M.; Coyle, D. B.; McGarry, J. F.; Bufton, J.; Cheek, J. W.; Clarke, G.; Hull, S. M.; Skillman, D. R.; Stysley, P. R.; Sun, X.;
2015-01-01
A previous study has indicated that by using approx.1550 nm wavelengths a laser ranging system can track debris objects in an "eye safe" manner, while increasing the expected return rate by a factor of approx. 2/unit area of the telescope. In this presentation we develop the optical bench required to use approx.1550nm lasers, and integration with a 532nm system. We will use the optical bench configuration for NGSLR as the baseline, and indicate a possible injection point for the 1550 nm laser. The presentation will include what elements may need to be changed for transmitting the required power on the approx.1550nm wavelength, supporting the alignment of the laser to the telescope, and possible concerns for the telescope optics.
Multiwavelength L-band fiber laser with bismuth-oxide EDF and photonic crystal fiber
NASA Astrophysics Data System (ADS)
Ramzia Salem, A. M.; Al-Mansoori, M. H.; Hizam, H.; Mohd Noor, S. B.; Abu Bakar, M. H.; Mahdi, M. A.
2011-05-01
A multiwavelength laser comb using a bismuth-based erbium-doped fiber and 50 m photonic crystal fiber is demonstrated in a ring cavity configuration. The fiber laser is solely pumped by a single 1455 nm Raman pump laser to exploit its higher power delivery compared to that of a single-mode laser diode pump. At 264 mW Raman pump power and 1 mW Brillouin pump power, 38 output channels in the L-band have been realized with an optical signal-to-noise ratio above 15 dB and a Stokes line spacing of 0.08 nm. The laser exhibits a tuning range of 12 nm and produces stable Stokes lines across the tuning range between Brillouin pump wavelengths of 1603 nm and 1615 nm.
NASA Astrophysics Data System (ADS)
Arun, S.; Choudhury, Vishal; Balaswamy, V.; Supradeepa, V. R.
2018-02-01
We have demonstrated a 34 W continuous wave supercontinuum using the standard telecom fiber (SMF 28e). The supercontinuum spans over a bandwidth of 1000 nm (>1 octave) from 880nm to 1900 nm with a substantial power spectral density of >1mW/nm from 880-1350 nm and 50-100mW/nm in 1350-1900 nm. The distributed feedback Raman laser architecture was used for pumping the supercontinuum which ensured high efficiency Raman conversions and helped in achieving a very high efficiency of 44% for supercontinuum generation. Using this architecture, Yb laser operating at any wavelength can be used for generating the supercontinuum and this was demonstrated by using two different Yb lasers operating at 1117nm and 1085 nm to pump the supercontinuum.
Lasers for tattoo removal: a review.
Choudhary, Sonal; Elsaie, Mohamed L; Leiva, Angel; Nouri, Keyvan
2010-09-01
Tattoos have existed and have been used as an expression of art by man for ages-and so have the techniques to remove them. Lasers based on the principle of selective photothermolysis are now being used to remove black as well as colorful tattoos with varying successes. The commonly used lasers for tattoo removal are the Q-switched 694-nm ruby laser, the Q-switched 755-nm alexandrite laser, the 1,064-nm Nd:YAG laser, and the 532-nm Nd:YAG laser. Newer techniques and methods are evolving in tattoo removal with lasers. Choosing the right laser for the right tattoo color is necessary for a successful outcome. Our review aims to understand the principles of laser tattoo removal and their applications for different types and colors of tattoos. The review also highlights the complications that can occur such as dyspigmentation, allergic reactions, epidermal debris, ink darkening, and so on, in this process and how to prevent them.
NASA Astrophysics Data System (ADS)
Li, Q.; Jia, Z. X.; Weng, H. Z.; Li, Z. R.; Yang, Y. D.; Xiao, J. L.; Chen, S. W.; Huang, Y. Z.; Qin, W. P.; Qin, G. S.
2018-05-01
We demonstrate broadband multi-wavelength Brillouin lasers with an operating wavelength range of 1500–1600 nm and a frequency separation of ~9.28 GHz generated by four-wave mixing in a dual wavelength Brillouin fiber laser cavity. By using one continuous-wave laser as the pump source, multi-wavelength Brillouin lasers with an operating wavelength range of 1554–1574 nm were generated via cascaded Brillouin scattering and four-wave mixing. Interestingly, when pumped by two continuous-wave lasers with an appropriate frequency separation, the operating wavelength range of the multi-wavelength Brillouin lasers was increased to 1500–1600 nm due to cavity-enhanced cascaded four-wave mixing among the frequency components generated by two pump lasers in the dual wavelength Brillouin laser cavity.
Lee, Ju Hwan; Park, So Ra; Jo, Jeong Ho; Park, Sung Yun; Seo, Young Kwon; Kim, Sung Min
2014-07-01
The purpose of this study was to compare degrees of epidermal/dermal tissue damage quantitatively and histologically after laser irradiation, to find ideal treatment conditions with relatively high fluence for skin rejuvenation. A number of recent studies have evaluated the clinical efficacy and safety of therapeutic lasers under relatively low fluence conditions. We transmitted the long-pulsed 1064 nm Nd:YAG and 755 nm Alexandrite lasers into pig skin according to different fluences and spot diameters, and estimated epidermal/dermal temperatures. Pig skin specimens were stained with hematoxylin and eosin for histological assessments. The fluence conditions comprised 26, 30, and 36 J/cm2, and the spot diameter conditions were 5, 8, and 10 mm. Pulse duration was 30 ms for all experiments. Both lasers produced reliable thermal damage on the dermis without any serious epidermal injuries, under relatively high fluence conditions. The 1064 nm laser provided more active fibrous formations than the 755 nm laser, while higher risks for tissue damages simultaneously occurred. The ideal treatment conditions for skin rejuvenation were 8 mm diameter with 30 J/cm2 and 10 mm diameter with 26 J/cm2 for the 1064 nm laser, and 8 mm diameter with 36 J/cm2 and 10 mm diameter with 26 J/cm2 for the 755 nm laser.
Extending solid state laser performance
NASA Astrophysics Data System (ADS)
Miesak, Ed
2017-02-01
Coherent Diode-Pumped Solid-State Orlando (CDO), formerly known as Lee Laser, headquartered in Orlando Florida produces CW and pulsed solid state lasers. Primary wavelengths include 1064 nm, 532 nm, and 355 nm. Other wavelengths produced include 1320 nm, 15xx nm, and 16xx nm. Pulse widths are in the range of singles to hundreds of nanoseconds. Average powers are in the range of a few watts to 1000 watts. Pulse repetition rates are typically in the range of 100 Hz to 100 KHz. Laser performance parameters are often modified according to customer requests. Laser parameters that can be adjusted include average power, pulse repetition rate, pulse length, beam quality, and wavelength. Laser parameters are typically cross-coupled such that adjusting one may change some or all of the others. Customers often request one or more parameters be changed without changing any of the remaining parameters. CDO has learned how to accomplish this successfully with rapid turn-around times and minimal cost impact. The experience gained by accommodating customer requests has produced a textbook of cause and effect combinations of laser components to accomplish almost any parameter change request. Understanding the relationships between component combinations provides valuable insight into lasing effects allowing designers to extend laser performance beyond what is currently available. This has led to several break through products, i.e. >150W average power 355 nm, >60W average power 6 ps 1064 nm, pulse lengths longer than 400 ns at 532 nm with average power >100W, >400W 532 nm with pulse lengths in the 100 ns range.
Fiber Raman laser and amplifier pumped by Nd3+:YVO4 solid state laser
NASA Astrophysics Data System (ADS)
Liu, Deming; Zhang, Minming; Liu, Shuang; Nie, Mingju; Wang, Ying
2005-04-01
Pumping source is the key technology of fiber Raman amplifiers (FRA) which are important for ultra long haul and high bit rate dense wavelength division multiplexing (DWDM) systems. In this paper the research work of the project, "Fiber Raman Laser and Amplifier pumped by Nd3+:YVO4 Solid State Laser", supported by the National High-tech Program (863-program) of China is introduced, in which a novel 14xx nm pump module with fine characteristics of high efficiency, simplicity, compactness and low cost is researched and developed. A compact 1342 nm Nd3+:YVO4 diode pumped solid state laser (DPSSL) module is developed with the total laser power of 655mW and the slope efficiency of 42.6% pumped by a 2W 808nm laser diode (LD). A special C-lens fiber collimator is designed to couple the 1342nm laser beam into a piece of single mode fiber (SMF) and the coupling efficiency of 80% is reached. The specific 14xx nm output laser is generated from a single stage Raman resonator which includes a pair of fiber Bragg gratings and a piece of Germanic-silicate or Phospho-silicate fiber pumped by such DPSSL module. The slope efficiency for conversion from 1342 to 14xx nm radiation is 75% and the laser power is more than 300mW each. Finally, Raman gain experiments are carried out with 100km SMF. 100 nm bandwidth with 10dB on-off Raman gain and 1.1dB gain flatness is achieved by pumped at 1425, 1438, 1455 and 1490nm.
Walgrave, Susan; Zelickson, Brian; Childs, James; Altshuler, Gregory; Erofeev, Andrei; Yaroslavsky, Ilya; Kist, David; Counters, Jeff
2008-11-01
Yucatan Black pig skin was treated with a 1,540-nm erbium (Er):glass laser (Lux1540, 15 and 30 mJ) and two 1,550-nm Er-doped fiber lasers (Fraxel SR750 and SR1500, 8, 10, and 12 mJ). Histologic sections were examined to determine the depth of damage and to correlate subjects' clinical response. Concurrently, six subjects with photodamaged skin received three split-face and ipsilateral dorsal hand treatments with the 1,540-nm Er:glass laser on one side and one of the 1,550-nm Er-doped lasers (Fraxel SR750) on the other. The 1,550-nm Er-doped lasers, using lower fluences and higher densities, produced shallower micro-columns than the 1,540-nm Er:glass device at higher fluences and lower densities (mean depths 250-275 microm vs 425-525 microm, respectively). Blinded assessors found greater overall improvement in pigmentation with the 1,550-nm Er-doped laser and better overall improvement in texture with the 1,540-nm Er:glass laser. Greater densities of shallower damage columns at lower energies may better improve pigmentation, whereas deeper injuries, using higher energies and moderate densities, may better improve texture. This pilot study did not compare similar fluences and histologic damage between the two systems, and newer available systems allow for greater depth of penetration.
Zang, Jie; Cong, Zhenhua; Chen, Xiaohan; Zhang, Xingyu; Qin, Zengguang; Liu, Zhaojun; Lu, Jianren; Wu, Dong; Fu, Qiang; Jiang, Shiqi; Zhang, Shaojun
2016-04-04
This paper presents the tunable Stokes laser characteristics of KTiOAsO4 (KTA) crystal based on stimulated polariton scattering (SPS). When the pumping laser wavelength is 1064.2 nm, the KTA Stokes wave can be discontinuously tuned from 1077.9 to 1088.4 nm with four gaps from 1079.0 to 1080.1 nm, from 1080.8 to 1082.8 nm, from 1083.6 to 1085.5 nm, and from 1085.8 to 1086.8 nm. When a frequency doubling crystal LiB3O5 (LBO) is inserted into the Stokes laser cavity, the frequency-doubled wave can be discontinuously tuned from 539.0 to 539.5 nm, from 540.1 to 540.4 nm, from 541.3 to 541.8 nm, from 542.7 to 542.9 nm and from 543.4 to 544.2 nm. With a pumping pulse energy of 130.0 mJ and an output coupler reflectivity of about 30%, the obtained maximum Stokes laser pulse energy at 1078.6 nm is 33.9 mJ and the obtained maximum frequency-doubled laser pulse energy at 543.8 nm is 15.7 mJ. By using the most probably coupled transverse optical modes obtained from the literature, the polariton refractive indexes, and the simplified polariton Sellmeier equations, the polariton dispersion curve is obtained. The formation of the Stokes frequency gaps is explained.
Min, Seong U K; Choi, Yu Sung; Lee, Dong Hun; Yoon, Mi Young; Suh, Dae Hun
2009-11-01
Nonablative laser is gaining popularity because of the low risk of complications, especially in patients with darker skin. To compare the efficacy and safety of a long-pulse neodymium-doped yttrium aluminium garnet (Nd:YAG) laser and a combined 585/1,064-nm laser for the treatment of acne scars. Nineteen patients with mild to moderate atrophic acne scars received four long-pulse Nd:YAG laser or combined 585/1,064-nm laser treatment sessions at fortnightly intervals. Treatments were administered randomly in a split-face manner. Acne scars showed mild to moderate improvement, with significant Echelle d'évaluation clinique des cicatrices d'acné (ECCA) score reductions, after both treatments. Although intermodality differences were not significant, combined 585/1,064-nm laser was more effective for deep boxcar scars. In patients with combined 585/1,064-nm laser-treated sides that improved more than long-pulse Nd:YAG laser-treated sides, ECCA scores were significantly lower for combined 585/1,064-nm laser treatment. Histologic evaluations revealed significantly greater collagen deposition, although there was no significant difference between the two modalities. Patient satisfaction scores concurred with physicians' evaluations. Both lasers ameliorated acne scarring with minimal downtime. In light of this finding, optimal outcomes might be achieved when laser treatment types are chosen after considering individual scar type and response.
NASA Astrophysics Data System (ADS)
Wu, Y.; Wang, A. H.; Zheng, R. R.; Tang, H. Q.; Qi, X. Y.; Ye, B.
2014-06-01
Three kinds of lasers at 1064, 532 and 355 nm wavelengths respectively were adopted to construct micro-hole arrays on polyurethane (PU) synthetic leather with an aim to improve water vapor permeability (WVP) of PU synthetic leather. The morphology of the laser-drilled micro-holes was observed to optimize laser parameters. The WVP and slit tear resistance of the laser-drilled leather were measured. Results show that the optimized pulse energy for the 1064, 532 and 355 nm lasers are 0.8, 1.1 and 0.26 mJ, respectively. The diameters of the micro-holes drilled with the optimized laser pulse energy were about 20, 15 and 10 μm, respectively. The depths of the micro-holes drilled with the optimized pulse energy were about 21, 60 and 69 μm, respectively. Compared with the untreated samples, the highest WVP growth ratio was 38.4%, 46.8% and 53.5% achieved by the 1064, 532 and 355 nm lasers, respectively. And the highest decreasing ratio of slit tear resistance was 11.1%, 14.8%, and 22.5% treated by the 1064, 532 and 355 nm lasers, respectively. Analysis of the interaction mechanism between laser beams at three kinds of laser wavelengths and the PU synthetic leather revealed that laser micro-drilling at 355 nm wavelength displayed both photochemical ablation and photothermal ablation, while laser micro-drilling at 1064 and 532 nm wavelengths leaded to photothermal ablation only.
Zhou, Rong; Tang, Pinghua; Chen, Yu; Chen, Shuqing; Zhao, Chujun; Zhang, Han; Wen, Shuangchun
2014-01-10
Nonlinear transmission parameters of monolayer graphene at 1645 nm were obtained. Based on the monolayer graphene saturable absorber, a 1532 nm LD pumped 1645 nm passively Q-switched Er:YAG laser was demonstrated. Under the pump power of 20.8 W, a 1645 nm Q-switched pulse with FWHM of 0.13 nm (without the use of etalon) and energy of 13.5 μJ per pulse can be obtained. To the best of our knowledge, this is the highest pulse energy for graphene-based passively Q-switched Er:YAG laseroperating at 1645 nm, suggesting the potentials of graphene materials for high-energy solid-state laser applications.
UV Generation of 25 mJ/pulse at 289 nm for Ozone Lidar
NASA Technical Reports Server (NTRS)
Storm, Mark E.; Marsh, Waverly; Barnes, James C.
1998-01-01
Our paper describes a technique for generating tunable UV laser radiation between 250-300 nm capable of energies up to 30-5O mJ/pulse. The tunability of this source is attractive for selecting ozone absorption cross sections which are optimal for ozone DIAL detection throughout the troposphere. A Nd:YAG laser is used to pump a pulsed titanium sapphire laser which is then frequency tripled into the UV. Titanium sapphire (TiS) lases robustly between 750-900 nm. In initial experiments we have converted 110 mJ of 867 nm from a TiS laser into 28 mJ at 289 nm. The energy conversion efficiency was 62% for doubling into 433 nm and 25% into 289 nm.
NASA Astrophysics Data System (ADS)
Tian, Hongchun; Zhang, Sa; Hou, Zhiyun; Xia, Changming; Zhou, Guiyao; Zhang, Wei; Liu, Jiantao; Wu, Jiale; Fu, Jian
2016-06-01
A stable dual-wavelength ytterbium-doped photonic crystal fiber laser pumped by a 976 nm laser diode has been demonstrated at room temperature. Single-wavelength, dual-wavelength laser oscillations are observed when the fiber laser operates under different pump power by using different length of fibers. Stable dual-wavelength radiation around 1045 nm and 1075 nm has been generated simultaneously at a high pump power directly from an ytterbium-doped fiber laser without using any spectral control mechanism. A small core ytterbium-doped PCF fabricated by the powder sinter direction drawn rod technology is used as gain medium. The pump power and fiber length which can affect the output characteristics of dual-wavelength fiber laser are analyzed in the experiment. Experiments confirm that higher pump power and longer fiber length favors 1075 nm output; lower pump power and shorter fiber length favors 1045 nm output. Those results have a good reference in multi-wavelength fiber laser.
Cr:ZnSe laser pumped with Tm:YAP microchip laser
NASA Astrophysics Data System (ADS)
Koranda, Petr; Sulc, Jan; Doroshenko, Maxim; Jelinková, Helena; Basiev, Tasoltan T.; Osiko, Vjatcheslav; Badikov, V. V.; Badikov, D.
2010-02-01
Cr:ZnSe laser coherently longitudinally pumped with Tm:YAP microchip laser was realised. The pumping laser consisted of Tm:YAP crystal (3x3 mm) with resonator mirrors deposited directly on its faces (on rear face the dielectric layer with high reflectance for 1998 nm wavelength and high transmittance for 790 nm pumping radiation wavelength; on output face the dielectric layer with reflectance 97% at 1998 nm wavelength). The maximal output power was 5.5 W and the generated radiation wavelength was 1998 nm. The main advantage of this pumping was stable and still output without relaxation spikes (non-spiking). The Tm:YAP laser radiation was collimated and focused by the set of two CaF2 lenses. The pumping beam spot diameter inside the Cr:ZnSe crystal was 300 μm. The Cr:ZnSe laser resonator consisted of flat rear mirror (HT at 1998 nm and HR at 2100 - 2900 nm) and curved output coupler (r = -150 mm, R = 95% at 2100 - 2700 nm). The maximal output energy of stable radiation was 4 mJ (pulse duration 10 ms, repetition rate 10 Hz). For wavelength tuning the Lyott filter (quartz plate under Brewster angle) was placed between the Cr:ZnSe crystal and output coupler. The generated radiation wavelength was continuously tunable from 2246 - 2650 nm.
NASA Astrophysics Data System (ADS)
Tozburun, Serhat; Stahl, Charlotte S. D.; Hutchens, Thomas C.; Lagoda, Gwen A.; Burnett, Arthur L.; Fried, Nathaniel M.
2013-03-01
Successful identification of the cavernous nerves (CN's) during radical prostatectomy requires detection of the CN's through a thin layer of overlying fascia. This study explores the 1490 nm infrared (IR) diode laser wavelength for rapid and deep subsurface CN stimulation in a rat model, in vivo. A 150-mW, 1490-nm diode laser providing an optical penetration depth of 520 μm was used to stimulate the CN's in 8 rats through a single mode fiber optic probe with 1-mm-diameter spot and 15 s irradiation time. Successful ONS was judged by an intracavernous pressure response (ICP) in the rat penis. Subsurface ONS at 1490 nm was also compared with previous studies using 1455 and 1550 nm IR diode laser wavelengths. ONS was observed through fascia layers up to 380 μm thick using an incident laser power of 50 mW. ICP response times as short as 4.6 +/- 0.2 s were recorded using higher laser powers bust still below the nerve damage threshold. The 1490-nm diode laser represents a compact, low cost, high power, and high quality infrared light source for use in ONS. This wavelength provides deeper optical penetration than 1455 nm and more rapid and efficient nerve stimulation than 1550 nm.
Impact of laser excitation intensity on deep UV fluorescence detection in microchip electrophoresis.
Schulze, Philipp; Ludwig, Martin; Belder, Detlev
2008-12-01
A high intensity 266 nm continuous wave (cw-) laser developed for material processing was utilised as an excitation source for sensitive native fluorescence detection of unlabelled compounds in MCE. This 120 mW laser was attached via an optical fibre into a commercial epifluorescence microscope. With this MCE set-up we evaluated the impact of laser power on the S/N of aromatic compounds as well as of proteins. Compared with a previous work which used a 4 mW pulsed laser for excitation, improved S/N for small aromatics and to a lesser extent for proteins could be attained. The LOD of the system was determined down to 24 ng/mL for serotonin (113 nM), 24 ng/mL for propranolol (81 nM), 80 ng/mL for tryptophan (392 nM) and 80 ng/mL for an aromatic diol (475 nM). Sensitive protein detection was obtained at concentrations of 5 microg/mL for lysocyme, trypsinogen and chymotrypsinogen (340, 208 and 195 nM, respectively). Finally, a comparison of the cw- with a pulsed 266 nm laser, operating at the same average power, showed a higher attainable sensitivity of the cw-laser. This can be attributed to fluorescence saturation and photobleaching effects of the pulsed laser at high pulse energies.
Tao, Joy; Champlain, Amanda; Weddington, Charles; Moy, Lauren; Tung, Rebecca
2018-01-01
Burn scars cause cosmetic disfigurement and psychosocial distress. We present two Fitzpatrick phototype (FP) III patients with burn scars successfully treated with combination pulsed dye laser (PDL) and non-ablative fractional lasers (NAFL). A 30-year-old, FP III woman with a history of a second-degree burn injury to the bilateral arms and legs affecting 30% body surface area (BSA) presented for cosmetic treatment. The patient received three treatments with 595 nm PDL (7 mm, 8 J, 6 ms), six with the 1550 nm erbium:glass laser (30 mJ, 14% density, 4-8 passes) and five with the 1927 nm thulium laser (10 mJ, 30% density, 4-8 passes). Treated burn scars improved significantly in thickness, texture and colour. A 33-year-old, FP III man with a history of a second-degree burn injury of the left neck and arm affecting 7% BSA presented for cosmetic treatment. The patient received two treatments with 595 nm PDL (5 mm, 7.5 J, 6 ms), four with the 1550 nm erbium:glass laser (30 mJ, 14% density, 4-8 passes) and two with the 1927 nm thulium laser (10 mJ, 30% density, 4-8 passes). The burn scars became thinner, smoother and more normal in pigmentation and appearance. Our patients' burn scars were treated with a combination of PDL and NAFL (two wavelengths). The PDL targets scar hypervascularity, the 1550 nm erbium:glass stimulates collagen remodelling and the 1927 nm thulium targets epidermal processes, particularly hyperpigmentation. This combination addresses scar thickness, texture and colour with a low side effect profile and is particularly advantageous in patients at higher risk of post-procedure hyperpigmentation. Our cases suggest the combination of 595nm PDL plus NAFL 1550 nm erbium:glass/1927 nm thulium device is effective and well-tolerated for burn scar treatment in skin of colour.
NASA Astrophysics Data System (ADS)
Csontos, J.; Toth, Z.; Pápa, Z.; Budai, J.; Kiss, B.; Börzsönyi, A.; Füle, M.
2016-06-01
In this work laser-induced periodic structures with lateral dimensions smaller than the central wavelength of the laser were studied on glassy carbon as a function of laser pulse duration. To generate diverse pulse durations titanium-sapphire (Ti:S) laser (center wavelength 800 nm, pulse durations: 35 fs-200 ps) and a dye-KrF excimer laser system (248 nm, pulse durations: 280 fs, 2.1 ps) were used. In the case of Ti:S laser treatment comparing the central part of the laser-treated areas a striking difference is observed between the femtoseconds and picoseconds treatments. Ripple structure generated with short pulse durations can be characterized with periodic length significantly smaller than the laser wavelength (between 120 and 165 nm). At higher pulse durations the structure has a higher periodic length (between 780 and 800 nm), which is comparable to the wavelength. In case of the excimer laser treatment the different pulse durations produced similar surface structures with different periodic length and different orientation. One of the structures was parallel with the polarization of the laser light and has a higher periodic length (~335 nm), and the other was perpendicular with smaller periodic length (~78-80 nm). The possible mechanisms of structure formation will be outlined and discussed in the frame of our experimental results.
Analysis of Ni-HYDRIDE Thin Film after Surface Plasmon Generation by Laser Technique
NASA Astrophysics Data System (ADS)
Violante, V.; Castagna, E.; Sibilia, C.; Paoloni, S.; Sarto, F.
2005-12-01
A nickel hydride thin film was studied by the attenuated total reflection method. The differences in behavior between a "black" film, and a pure nickel film "blank," are shown. The black nickel hydride film has been obtained by a short electrolysis with 1 M Li2SO4 electrolyte in light water, A shift in the minimum of the observed reflected light occurs, together with a change in the minimum shape (i.e. its half-height width increases). These two phenomenon are due to the change in the electronic band structure of the metal induced by electrons added to the lattice by hydrogen. The change of the electronic structure, revealed by the laser coupling conditions, leads us to consider that a hydride phase was created. Both the blank (not hydrogenated) and black (hydrogenated) specimens were taken under He-Ne laser beam at the reflectance minimum angle for about three hours. A SIMS analysis was also implemented to reveal differences in the isotopic composition of Cu, as marker element between the blank and black films, in order to study the coupled effect of electrolysis and plasmon-polariton excitation on LENR processes in condensed matter.
Views on treatment of endometriosis by using laser acupuncture and moxibustion
NASA Astrophysics Data System (ADS)
Ye, Hongzheng
1993-03-01
This article emphasizes the treatment of endometriosis by using laser acupuncture and moxibustion which belongs to Shi Zhen. The major pathophysiology is that the circulation of the Qi and blood is obstructed. The obstruction of Qi leads to a block of blood and poor circulation which causes pain. The treatment should be introduced mainly by adjusting Qi and blood. We used an He-Ne low level laser instrument. Its export function is >= 20 mw, wavelength 6328 angstroms with a single-red light. By using a double tube fiber bundle it strikes directly on Liv. 3, Ren. 6, SP. 8. Each of the three points needs to be struck for five to ten minutes once a day. One therapy phase requires seven applications continually. This treatment results in cleaning the liver, adjusting the oxygen, and disencumbering the piles and the pain. When it makes the circulation of Qi free, the blood is normally transported and the pain disappears. After one or two phases of therapy, clinical re-examination indicated the disappearance of scleromata in the uterus. Five patients treated and continually re-checked recovered. Finally, their menses turned normal and clinical symptoms vanished within six months.
Semiconductor lasers with a continuous tuning range above 100 nm in the nearest IR spectral region
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kostin, Yu O; Lobintsov, A A; Shramenko, M V
2015-08-31
We have developed two new types of lasers based on quantum-confined semiconductor optical amplifiers with an acousto-optic tunable filter in an external fibre ring cavity. The lasers offer continuous wavelength tuning ranges from 780 to 885 and from 880 to 1010 nm, 20 mW of cw output power, and a tuning rate up to 10{sup 4} nm s{sup -1} at an instantaneous spectral linewidth less than 0.1 nm. (lasers)
Photonic Breast Tomography and Tumor Aggressiveness Assessment
2012-07-01
c) Raw Image 11 The entrance face of the slab sample (source plane) was illuminated by a 100-mW 790-nm diode laser beam. The multi-source...schematically shown in Figure 6. A 10mW 785 nm diode laser beam was used to illuminate the first sample, while a 100mW 785 nm diode laser beam was used for the...signal transmitting narrow-band filter; TS = translation stage; CCD = charge cou- pled device; and PC = computer. Continuous wave 790-nm diode laser
Diffraction-analysis-based characterization of very fine gratings
NASA Astrophysics Data System (ADS)
Bischoff, Joerg; Truckenbrodt, Horst; Bauer, Joachim J.
1997-09-01
Fine gratings with spatial periods below one micron, either ruled mechanically or patterned holographically, play a key role as encoders in high precision translational or rotational coordinate or measuring machines. Besides, the fast in-line characterization of submicron patterns is a stringent demand in recent microelectronic technology. Thus, a rapid, destruction free and highly accurate measuring technique is required to ensure the quality during manufacturing and for final testing. We propose an optical method which was already successfully introduced in semiconductor industry. Here, the inverse scatter problem inherent in this diffraction based approach is overcome by sophisticated data analysis such as multivariate regression or neural networks. Shortly sketched, the procedure is as follows: certain diffraction efficiencies are measured with an optical angle resolved scatterometer and assigned to a number of profile parameters via data analysis (prediction). Before, the specific measuring model has to be calibrated. If the wavelength-to-period rate is well below unity, it is quite easy to gather enough diffraction orders. However, for gratings with spatial periods being smaller than the probing wavelength, merely the specular reflex will propagate for perpendicular incidence (zero order grating). Consequently, it is virtually impossible to perform a regression analysis. A proper mean to tackle this bottleneck is to record the zero-order reflex as a function of the incident angle. In this paper, the measurement of submicron gratings is discussed with the examples of 0.8, 1.0 and 1.4 micron period resist gratings on silicon, etched silicon oxide on silicon (same periods) and a 512 nm pitch chromium grating on quartz. Using a He-Ne laser with 633 nm wavelength and measuring the direct reflex in both linear polarizations, it is shown that even submicron patterning processes can be monitored and the resulting profiles with linewidths below a half micron can be characterized reliably with 2(theta) - scatterometry.
High efficiency laser-pumped emerald lasers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lai, S.T.
1987-09-25
Highly efficient laser operation has been achieved in emerald. In a quasi-cw laser-pumped emerald laser, 64% output slope efficiency has been measured at 768 nm, corresponding to a laser quantum yield of 76%. An output power of 1.6 W was reached at 3.6 W of pump power at 647.1 nm from a krypton laser, and was pump power limited. The emerald laser has a tuning range of 720 to 842 nm. The round trip loss excluding the excited state absorption (ESA) is 0.4%/cm. These results indicate the high laser efficiency and the high optical quality of the emerald attainable inmore » the present laser.« less
Saturable absorber Q- and gain-switched all-Yb3+ all-fiber laser at 976 and 1064 nm.
Tsai, Tzong-Yow; Fang, Yen-Cheng; Huang, Huai-Min; Tsao, Hong-Xi; Lin, Shih-Ting
2010-11-08
We demonstrate a novel passively pulsed all-Yb3+ all-fiber laser pumped by a continuous-wave 915-nm pump laser diode. The laser was saturable absorber Q-switched at 976 nm and gain-switched at 1064 nm, using the method of mode-field-area mismatch. With a pump power of 105 mW, the laser iteratively produced a 976-nm pulse with an energy of 2.8 μJ and a duration of 280 ns, followed by a 1064-nm pulse with 1.1 μJ and a 430-ns duration at a repetition rate of 9 kHz. A set of rate equations was established to simulate the self-balancing mechanism and the correlation between the Q- and gain-switched photon numbers and the populations of the gain and absorber fibers.
NASA Astrophysics Data System (ADS)
Fu, S. C.; Wang, X.; Chu, H.
2013-02-01
We report the generation of a green laser at 543 nm by intracavity frequency doubling of the continuous-wave (cw) laser operation of a 1086 nm Nd:YVO4 laser under 888 nm diode pumping into the emitting level 4F3/2. An LiB3O5 (LBO) crystal, cut for critical type I phase matching at room temperature, is used for the laser second-harmonic generation. At an incident pump power of 17.8 W, as high as 4.53 W cw output power at 543 nm is achieved. The optical-to-optical conversion efficiency is up to 25.4%, and the fluctuation of the green output power is better than 2.3% in a 30 min period.
Carbon Nanotube Mode-Locked Thulium Fiber Laser With 200 nm Tuning Range
Meng, Yafei; Li, Yao; Xu, Yongbing; Wang, Fengqiu
2017-01-01
We demonstrated a mode-locked thulium/holmium (Tm/Ho) fiber laser continuously tunable across 200 nm (from 1860 nm to 2060 nm), which to the best of our knowledge represents the widest tuning range ever achieved for a passively mode-locked fiber laser oscillator. The combined use of a broadband carbon nanotube (CNT) saturable absorber and a diffraction grating mirror ensures ultra-broad tuning range, superb stability and repeatability, and makes the demonstrated laser a highly practical source for spectroscopy, imaging and optical communications. The laser emits <5 ps pulses with an optical spectral bandwidth of ∼3 nm across the full tuning range. Our results indicate that carbon nanotubes can be an excellent saturable absorber for achieving gain-bandwidth-limited tunable operation for 2 μm thulium fiber lasers. PMID:28322327
Carbon Nanotube Mode-Locked Thulium Fiber Laser With 200 nm Tuning Range
NASA Astrophysics Data System (ADS)
Meng, Yafei; Li, Yao; Xu, Yongbing; Wang, Fengqiu
2017-03-01
We demonstrated a mode-locked thulium/holmium (Tm/Ho) fiber laser continuously tunable across 200 nm (from 1860 nm to 2060 nm), which to the best of our knowledge represents the widest tuning range ever achieved for a passively mode-locked fiber laser oscillator. The combined use of a broadband carbon nanotube (CNT) saturable absorber and a diffraction grating mirror ensures ultra-broad tuning range, superb stability and repeatability, and makes the demonstrated laser a highly practical source for spectroscopy, imaging and optical communications. The laser emits <5 ps pulses with an optical spectral bandwidth of ˜3 nm across the full tuning range. Our results indicate that carbon nanotubes can be an excellent saturable absorber for achieving gain-bandwidth-limited tunable operation for 2 μm thulium fiber lasers.
Picosecond 1064-nm fiber laser with tunable pulse width and low timing jitter
NASA Astrophysics Data System (ADS)
Tian, Wenyan; Zhang, Shukui
2018-02-01
We report an all-fiber, linearly polarized, 1.1-W, 1064-nm fiber laser based on a two-stage Ytterbium-doped fiber amplifier seeded by a gain-switched diode laser with tunable pulse width from 21 to 200 ps at repetition rates of 0.5-1.5 GHz. Timing jitter of our 1064-nm fiber laser was measured to be 0.60 ps over 10 Hz-40 MHz when the gain-switched diode laser was operated at a repetition rate of 0.5, 1, and 1.5 GHz. The fiber laser offers an excellent long term power stability of +/- 0.3% and wavelength stability of +/- 0.01 nm over 8 hours
Efficient generation of 509 nm light by sum-frequency mixing between two tapered diode lasers
NASA Astrophysics Data System (ADS)
Tawfieq, Mahmoud; Jensen, Ole Bjarlin; Hansen, Anders Kragh; Sumpf, Bernd; Paschke, Katrin; Andersen, Peter E.
2015-03-01
We demonstrate a concept for visible laser sources based on sum-frequency generation of beam combined tapered diode lasers. In this specific case, a 1.7 W sum-frequency generated green laser at 509 nm is obtained, by frequency adding of 6.17 W from a 978 nm tapered diode laser with 8.06 W from a 1063 nm tapered diode laser, inside a periodically poled MgO doped lithium niobate crystal. This corresponds to an optical to optical conversion efficiency of 12.1%. As an example of potential applications, the generated nearly diffraction-limited green light is used for pumping a Ti:sapphire laser, thus demonstrating good beam quality and power stability. The maximum output powers achieved when pumping the Ti:sapphire laser are 226 mW (CW) and 185 mW (mode-locked) at 1.7 W green pump power. The optical spectrum emitted by the mode-locked Ti:sapphire laser shows a spectral width of about 54 nm (FWHM), indicating less than 20 fs pulse width.
2012-01-01
Background Activated microglial cells are an important pathological component in brains of patients with neurodegenerative diseases. The purpose of this study was to investigate the effect of He-Ne (632.8 nm, 64.6 mW/cm2) low-level laser therapy (LLLT), a non-damaging physical therapy, on activated microglia, and the subsequent signaling events of LLLT-induced neuroprotective effects and phagocytic responses. Methods To model microglial activation, we treated the microglial BV2 cells with lipopolysaccharide (LPS). For the LLLT-induced neuroprotective study, neuronal cells with activated microglial cells in a Transwell™ cell-culture system were used. For the phagocytosis study, fluorescence-labeled microspheres were added into the treated microglial cells to confirm the role of LLLT. Results Our results showed that LLLT (20 J/cm2) could attenuate toll-like receptor (TLR)-mediated proinflammatory responses in microglia, characterized by down-regulation of proinflammatory cytokine expression and nitric oxide (NO) production. LLLT-triggered TLR signaling inhibition was achieved by activating tyrosine kinases Src and Syk, which led to MyD88 tyrosine phosphorylation, thus impairing MyD88-dependent proinflammatory signaling cascade. In addition, we found that Src activation could enhance Rac1 activity and F-actin accumulation that typify microglial phagocytic activity. We also found that Src/PI3K/Akt inhibitors prevented LLLT-stimulated Akt (Ser473 and Thr308) phosphorylation and blocked Rac1 activity and actin-based microglial phagocytosis, indicating the activation of Src/PI3K/Akt/Rac1 signaling pathway. Conclusions The present study underlines the importance of Src in suppressing inflammation and enhancing microglial phagocytic function in activated microglia during LLLT stimulation. We have identified a new and important neuroprotective signaling pathway that consists of regulation of microglial phagocytosis and inflammation under LLLT treatment. Our research may provide a feasible therapeutic approach to control the progression of neurodegenerative diseases. PMID:22989325
NASA Astrophysics Data System (ADS)
Qian, Min; Niu, Yue Ping; Gong, Shang Qing
2018-01-01
Pulsed Nd:YAG (532 nm) and Excimer (248 nm) lasers were employed to produce freestanding, two-dimensional (2D), carbon nanosheets (CNSs) from naphthalene, through laser-induced exfoliation. The polymer-to-carbon transition was investigated in terms of laser wavelengths, fluences, as well as target preparations. Continuous and porous CNSs of several nanometers in thickness and micrometers in size were obtained from 532 and 248 nm pulsed laser exfoliation of spin-coated naphthalene films, respectively. The porous morphology is ascribed to the photon-induced dissociation of chemical bonds dominated in 248 nm laser interaction with ablated naphthalene. With the increase of laser fluences from 1 to 5 J cm-2, amorphous carbon and ultrathin CNS structures were obtained in sequence. This work revealed a general mechanism of producing 2D structured carbon materials from pulsed laser exfoliation.
NASA Astrophysics Data System (ADS)
Odor, Alin A.; Violant, Deborah; Badea, Victoria; Gutknecht, Norbert
2016-03-01
Backgrounds: Er,Cr:YSGG (2780nm) and diode (940 nm) lasers can be used adjacent to the conventional periodontal treatment as minimally invasive non-surgical devices. Aim: To describe the short-term clinical outcomes by combining Er,Cr:YSGG (2780nm) and diode 940 nm lasers in non-surgical periodontal treatment. Materials and methods: A total of 10 patients with periodontal disease (mild, moderate, severe) - 233 teeth and 677 periodontal pockets ranging from 4 mm to 12 mm - were treated with Er,Cr:YSGG (2780nm) and diode (940 nm) lasers in adjunct to manual and piezoelectric scaling and root planning (SRP). Periodontal parameters such as mean probing depth (PD), mean clinical attachment level (CAL) and mean bleeding on probing (BOP) were evaluated at baseline and 6 months after the laser treatment using an electronic periodontal chart. Results: At baseline, the mean PD was 4.06 ± 1.06 mm, mean CAL was 4.56 ± 1.43 mm, and mean BOP was 43.8 ± 23.84 %. At 6 months after the laser supported periodontal treatments the mean PD was 2.6 ± 0.58 mm (p <0.001), mean CAL was 3.36 ± 1.24 mm (p <0.001) and mean BOP was 17 ± 9.34 % (p <0.001). Also 3 patients showed radiographic signs of bone regeneration. Conclusion: The combination of two laser wavelengths in adjunct to SRP offers significant improvements of periodontal clinical parameters such as PD, CAL and BOP. Keywords: Laser supported periodontal treatment concept, Er,Cr:YSGG and diode 940nm lasers, Scaling and root planning, Minimally invasive non-surgical device
Diffraction-limited 577 nm true-yellow laser by frequency doubling of a tapered diode laser
NASA Astrophysics Data System (ADS)
Christensen, Mathias; Vilera, Mariafernanda; Noordegraaf, Danny; Hansen, Anders K.; Buß, Thomas; Jensen, Ole B.; Skovgaard, Peter M. W.
2018-02-01
A wide range of laser medical treatments are based on coagulation of blood by absorption of the laser radiation. It has, therefore, always been a goal of these treatments to maximize the ratio of absorption in the blood to that in the surrounding tissue. For this purpose lasers at 577 nm are ideal since this wavelength is at the peak of the absorption in oxygenated hemoglobin. Furthermore, 577 nm has a lower absorption in melanin when compared to green wavelengths (515 - 532 nm), giving it an advantage when treating at greater penetration depth. Here we present a laser system based on frequency doubling of an 1154 nm Distributed Bragg Reflector (DBR) tapered diode laser, emitting 1.1 W of single frequency and diffraction limited yellow light at 577 nm, corresponding to a conversion efficiency of 30.5%. The frequency doubling is performed in a single pass configuration using a cascade of two bulk non-linear crystals. The system is power stabilized over 10 hours with a standard deviation of 0.13% and the relative intensity noise is measured to be 0.064 % rms.