Science.gov

Sample records for noble liquid detectors

  1. Using 220Rn to calibrate liquid noble gas detectors

    NASA Astrophysics Data System (ADS)

    Kobayashi, M.; Yamashita, M.; Takeda, A.; Kishimoto, K.; Moriyama, S.

    2016-07-01

    In this paper, we describe 220Rn calibration source that was developed for liquid noble gas detectors. The key advantage of this source is that it can provide 212Bi-212 Po consecutive events, which enables us to evaluate the vertex resolution of a detector at low energy by comparing low-energy events of 212Bi and corresponding higher-energy α-rays from 212Po. Since 220Rn is a noble gas, a hot metal getter can be used when introduced using xenon as the carrier gas. In addition, no long-life radioactive isotopes are left behind in the detector after the calibration is complete; this has clear advantage over the use of 222Rn which leaves longlife radioactivity, i.e., 210Pb. Using a small liquid xenon test chamber, we developed a system to introduce 220Rn via the xenon carrier gas; we demonstrated the successful introduction of 6 × 102 220Rn atoms in our test environment.

  2. Photosensitive dopants for liquid noble gases

    DOEpatents

    Anderson, David F.

    1988-01-01

    In an ionization type detector for high energy radiation wherein the energy of incident radiation is absorbed through the ionization of a liquid noble gas and resulting free charge is collected to form a signal indicative of the energy of the incident radiation, an improvement comprising doping the liquid noble gas with photosensitive molecules to convert scintillation light due to recombination of ions, to additional free charge.

  3. Solubility investigations in support of ultrasensitive noble gas detector development.

    SciTech Connect

    Gross, K. C.

    1998-08-05

    Argonne National Laboratory (ANL) and the University of Cincinnati (UC) have been developing a new class of ultrasensitive noble gas detectors that are based upon the ANL discovery that corn oil has a high affinity for heavy noble gas absorption at room temperature, but releases the noble gases with warming or by other low-energy-input means. Environmental applications for this new class of fluid-based detectors include ultrahigh sensitivity radioxenon detectors for Comprehensive Test Ban Treaty Surveillance, improved fission gas detectors for enhanced environmental surveillance in the vicinity of DOE, DOD, and NRC-licensed facilities, and improved integrating Rn detectors for earthquake prediction. The purpose of the present paper is to present the results of theoretical and experimental investigations into the solubility phenomena of heavy noble gases (Rn, Xe, and Kr) in triglyceride oils. It is the authors' intention that the findings presented herein may be used to guide future selection, development, and refinement of vegetable and other hydrocarbon oils to bring further enhancements to noble gas detection efficiencies.

  4. High Voltage in Noble Liquids for High Energy Physics

    SciTech Connect

    Rebel, B.; Bernard, E.; Faham, C. H.; Ito, T. M.; Lundberg, B.; Messina, M.; Monrabal, F.; Pereverzev, S. P.; Resnati, F.; Rowson, P. C.; Soderberg, M.; Strauss, T.; Tomas, A.; Va'vra, J.; Wang, H.

    2014-08-22

    A workshop was held at Fermilab November 8-9, 2013 to discuss the challenges of using high voltage in noble liquids. The participants spanned the fields of neutrino, dark matter, and electric dipole moment physics. All presentations at the workshop were made in plenary sessions. This document summarizes the experiences and lessons learned from experiments in these fields at developing high voltage systems in noble liquids.

  5. Ultrasonic liquid level detector

    DOEpatents

    Kotz, Dennis M.; Hinz, William R.

    2010-09-28

    An ultrasonic liquid level detector for use within a shielded container, the detector being tubular in shape with a chamber at its lower end into which liquid from in the container may enter and exit, the chamber having an ultrasonic transmitter and receiver in its top wall and a reflector plate or target as its bottom wall whereby when liquid fills the chamber a complete medium is then present through which an ultrasonic wave may be transmitted and reflected from the target thus signaling that the liquid is at chamber level.

  6. Liquid level detector

    DOEpatents

    Grasso, A.P.

    1984-02-21

    A liquid level detector for low pressure boilers. A boiler tank, from which vapor, such as steam, normally exits via a main vent, is provided with a vertical side tube connected to the tank at the desired low liquid level. When the liquid level falls to the level of the side tube vapor escapes therethrough causing heating of a temperature sensitive device located in the side tube, which, for example, may activate a liquid supply means for adding liquid to the boiler tank. High liquid level in the boiler tank blocks entry of vapor into the side tube, allowing the temperature sensitive device to cool, for example, to ambient temperature.

  7. Liquid level detector

    DOEpatents

    Grasso, Albert P.

    1986-01-01

    A liquid level detector for low pressure boilers. A boiler tank, from which apor, such as steam, normally exits via a main vent, is provided with a vertical side tube connected to the tank at the desired low liquid level. When the liquid level falls to the level of the side tube vapor escapes therethrough causing heating of a temperature sensitive device located in the side tube, which, for example, may activate a liquid supply means for adding liquid to the boiler tank. High liquid level in the boiler tank blocks entry of vapor into the side tube, allowing the temperature sensitive device to cool, for example, to ambient temperature.

  8. Liquid level detector

    DOEpatents

    Tshishiku, Eugene M.

    2011-08-09

    A liquid level detector for conductive liquids for vertical installation in a tank, the detector having a probe positioned within a sheath and insulated therefrom by a seal so that the tip of the probe extends proximate to but not below the lower end of the sheath, the lower end terminating in a rim that is provided with notches, said lower end being tapered, the taper and notches preventing debris collection and bubble formation, said lower end when contacting liquid as it rises will form an airtight cavity defined by the liquid, the interior sheath wall, and the seal, the compression of air in the cavity preventing liquid from further entry into the sheath and contact with the seal. As a result, the liquid cannot deposit a film to form an electrical bridge across the seal.

  9. Modeling nuclear and electronic recoils in noble gas detectors with NEST

    NASA Astrophysics Data System (ADS)

    Mock, Jeremy; NEST Collaboration

    2015-10-01

    Noble gases such as xenon and argon are used as targets in single and dual phased rare event detectors like those used in the search for dark matter. Such experiments require an understanding of the behavior of the target material in the presence of low-energy ionizing radiation. This understanding allows an exploration of detector effects such as threshold, energy and position reconstruction, and pulse shape discrimination. The Noble Element Simulation Technique (NEST) package is a comprehensive code base that models the scintillation and ionization yields from liquid and gaseous xenon and argon in the energy regimes of interest to many types of experiments, like dark matter and neutrino detectors. NEST is built on multiple physics models, which are constrained by available data for both electronic and nuclear recoils. A substantial body of data exists in the literature, and we are reaching an era in which sub-keV yields can be explored experimentally. Here we present a new global analysis of all available nuclear recoil data, and the latest updates to the electronic recoil model, in light of recent low-energy measurements and an improved understanding of detector systematics.

  10. Results from the XENON10 and the Race to Detect Dark Matter with Noble Liquids

    ScienceCinema

    Shutt, Tom [Case Western Reserve, Cleveland, Ohio, United States

    2016-07-12

    Detectors based on liquid noble gases have the potential to revolutionize the direct search for WIMP dark matter. The XENON10 experiment, of which I am a member, has recently announced the results from it's first data run and is now the leading WIMP search experiment. This and other experiments using xenon, argon and neon have the potential to rapidly move from the current kg-scale target mass to the ton scale and well beyond. This should allow a (nearly) definitive test or discovery of dark matter if it is in the form of weakly interacting massive particles.

  11. Surface entropy of liquid transition and noble metals

    NASA Astrophysics Data System (ADS)

    Gosh, R. C.; Das, Ramprosad; Sen, Sumon C.; Bhuiyan, G. M.

    2015-07-01

    Surface entropy of liquid transition and noble metals has been investigated using an expression obtained from the hard-sphere (HS) theory of liquid. The expression is developed from the Mayer's extended surface tension formula [Journal of Non-Crystalline Solids 380 (2013) 42-47]. For interionic interaction in metals, Brettonet-Silbert (BS) pseudopotentials and embedded atom method (EAM) potentials have been used. The liquid structure is described by the variational modified hypernetted chain (VMHNC) theory. The essential ingredient of the expression is the temperature dependent effective HS diameter (or packing fraction), which is calculated from the aforementioned potentials together with the VMHNC theory. The obtained results for the surface entropy using the effective HS diameter are found to be good in agreement with the available experimental as well as other theoretical values.

  12. Liquid Hydrogen: Target, Detector

    SciTech Connect

    Mulholland, G.T.; Harigel, G.G.

    2004-06-23

    In 1952 D. Glaser demonstrated that a radioactive source's radiation could boil 135 deg. C superheated-diethyl ether in a 3-mm O glass vessel and recorded bubble track growth on high-speed film in a 2-cm3 chamber. This Bubble Chamber (BC) promised improved particle track time and spatial resolution and cycling rate. Hildebrand and Nagle, U of Chicago, reported Liquid Hydrogen minimum ionizing particle boiling in August 1953. John Wood created the 3.7-cm O Liquid Hydrogen BC at LBL in January 1954. By 1959 the Lawrence Berkley Laboratory (LBL) Alvarez group's '72-inch' BC had tracks in liquid hydrogen. Within 10 years bubble chamber volumes increased by a factor of a million and spread to every laboratory with a substantial high-energy physics program. The BC, particle accelerators and special separated particle beams created a new era of High Energy Physics (HEP) experimentation. The BC became the largest most complex cryogenic installation at the world's HEP laboratories for decades. The invention and worldwide development, deployment and characteristics of these cryogenic dynamic target/detectors and related hydrogen targets are described.

  13. Cryogenic gaseous photomultipliers and liquid hole- multipliers: advances in THGEM-based sensors for future noble-liquid TPCs

    NASA Astrophysics Data System (ADS)

    Arazi, L.; Coimbra, A. E. C.; Erdal, E.; Israelashvili, I.; Rappaport, M. L.; Shchemelinin, S.; Vartsky, D.; dos Santos, J. M. F.; A, Breskin

    2015-11-01

    Dual-phase noble-liquid TPCs are presently the most sensitive instruments for direct dark matter detection. Scaling up existing ton-scale designs to the multi-ton regime may prove to be technologically challenging. This includes both large-area coverage with affordable high-QE UV-photon detectors, and maintaining high precision in measuring the charge and light signals of rare events with keV-scale energy depositions. We present our recent advances in two complementary approaches to these problems: large-area cryogenic gaseous photomultipliers (GPM) for UV-photon detection, and liquid-hole multipliers (LHM) that provide electroluminescence light in response to ionization electrons and primary scintillation photons, using perforated electrodes immersed within the noble liquid. Results from a 10 cm diameter GPM coupled to a dual-phase liquid- xenon TPC demonstrate the feasibility of recording - for the first time - both primary (“S1”) and secondary (“S2”) scintillation signals, over a very broad dynamic range. The detector, comprising a triple-THGEM structure with CsI on the first element, has been operating stably at 180 K with gains larger than 105; it provided high single-photon detection efficiency - in the presence of massive alpha-particle induced S2 signals; S1 scintillation signals were recorded with time resolutions of 1.2 ns (RMS). Results with the LHM operated in liquid xenon yielded large photon gains, with a pulse-height resolution of 11% (RMS) for alpha-particle induced S2 signals. The detector response was stable over several months. The response of the S2 signals to rapid changes in pressure lead to the conclusion that the underlying mechanism for S2 light is electroluminescence in xenon bubbles trapped below the immersed THGEM electrode. Both studies have the potential of paving the way towards new designs of dual- and single-phase noble-liquid TPCs that could simplify the conception of future multi-ton detectors of dark matter and other rare

  14. Development and Testing of a High Voltage Feedthrough for Noble Liquid TPCs

    NASA Astrophysics Data System (ADS)

    Teymourian, Artin; Meng, Yixiong; Pantic, Emilija; Wang, Hanguo

    2013-04-01

    Noble liquid Time Projection Chambers (TPCs) are used in many experiments for the detection of WIMPs and neutrinos. In a TPC, an incoming particle deposits energy in the target material (liquid argon or liquid xenon) and creates scintillation light, which is detected by photodetectors. The deposited energy also ionizes some of the atoms of the target material, and the ionized electrons are drifted toward a gas phase or charge readout wires as a secondary signal. The TPCs require electric fields on the order of 1 kV/cm in order to drift the ionized electrons. For this reason, larger TPCs will require higher voltages to maintain the same electric field. The voltage required for the electric field is provided by a high voltage feedthrough. In this talk, I will present the development and testing of a high voltage feedthrough at UCLA capable of exceeding 100 kV in liquid argon and liquid xenon TPCs. This feedthrough design will be used in the future XENON1Ton, DarkSide50, and LBNE detectors. The feedthrough must withstand the high voltage and should be vacuum tight. In the case of dark matter detectors, the feedthrough must also be constructed with materials that contain ultra-low intrinsic radioactivity.

  15. Liquid level detector

    DOEpatents

    Tokarz, Richard D.

    1982-01-01

    A liquid level sensor having a pair of upright conductors spaced by an insulator defining a first high resistance path between the conductors. An electrically conductive path is interposed between the upright conductors at a discrete location at which liquid level is to be measured. It includes a liquid accessible gap of a dimension such that the electrical resistance across the conductor when the gap is filled with the liquid is detectably less than when the gap is emptied. The conductor might also be physically altered by temperature changes to serve also as an indicator of elevated temperature.

  16. Liquid-level detector

    DOEpatents

    Not Available

    1981-01-29

    Aliquid level sensor is described which has a pair of upright conductors spaced by an insulator defining a first high resistance path between the conductors. An electrically conductive path is interposed between the upright conductors at a discrete location at which liquid level is to be measured. It includes a liquid accessible gap of a dimension such that the electrical resistance across the conductor when the gap is filled with the liquid is detectably less than when the gap is emptied. The conductor might also be physically altered by temperature changes to serve also as an indicator of elevated temperature.

  17. Nanostructured elastomers: From smectic liquid crystals to noble metal nanocomposites

    NASA Astrophysics Data System (ADS)

    Lentz, Daniel M.

    Noble metal/polymer nanocomposites are a desirable and useful class of material due to their combination of the beneficial processibility and mechanical properties of polymers with the optical, electrical, barrier, and other engineering properties of metal nanoparticles. Potential applications of such materials include non-linear optical materials with gold nanoparticles or conductive polymer substrates with percolated silver nanoparticles. A processing approach has been developed whereby metal nanoparticles, especially silver and gold, can be infused into the surface of a thermoplastic elastomer following the melt processing operation. This reaction-diffusion approach (nanoinfusion) allows metal nanoparticles to be introduced at relatively low cost while avoiding the issues of thermal degradation, microphase separation, or agglomeration that can occur at elevated temperatures in the melt state. The nanoinfusion process involves immersion of a molded, cast, or extruded plastic article in an aqueous plasticizer solution (Bayer MaterialScience AURARTM Infusion Technology) containing a metal salt such as HAuCl4 or AgNO 3. Infusion of the metal salt into the plastic surface is achieved well below the melt-processing temperature due to plasticization of a thin surface layer of 10-500 microm. The metal salt is subsequently reduced to produce zero-valent metal nanoparticles by a second infusion of a reducing agent or a thermal or photochemical reduction process. The growth and agglomeration of the nanoparticles is arrested by the high viscosity of the polymer matrix, producing a stable nanocomposite. In order to examine how nanoparticle size distribution and concentration are affected by soak times in the salt and reducing agent solutions, combinatorial, high-throughput screening methods have been applied. Particle size distributions are characterized rapidly by small-angle x-ray scattering (SAXS) using a "dual gradient" nanoinfusion matrix. In addition, an improved

  18. Liquid-phase chromatography detector

    DOEpatents

    Voigtman, E.G.; Winefordner, J.D.; Jurgensen, A.R.

    1983-11-08

    A liquid-phase chromatography detector comprises a flow cell having an inlet tubular conduit for receiving a liquid chromatographic effluent and discharging it as a flowing columnar stream onto a vertically adjustable receiving surface spaced apart from and located vertically below and in close proximity to the discharge end of the tubular conduit; a receiver adapted to receive liquid overflowing from the receiving surface; an exit conduit for continuously removing liquid from the receiver; a light source for focusing fluorescence-producing light pulses on the flowing columnar stream as it passes from the outlet of the conduit to the receiving surface and a fluorescence detector to detect the produced fluorescence; a source of light pulse for producing acoustic waves in the columnar stream as it passes from the conduit outlet to the receiving surface; and a piezoelectric transducer adapted to detect those waves; and a source of bias voltage applied to the inlet tubular conduit and adapted to produce ionization of the liquid flowing through the flow cell so as to produce photocurrents therein and an electrical system to detect and record the photocurrents. This system is useful in separating and detecting individual chemical compounds from mixtures thereof. 5 figs.

  19. Liquid-phase chromatography detector

    DOEpatents

    Voigtman, Edward G.; Winefordner, James D.; Jurgensen, Arthur R.

    1983-01-01

    A liquid-phase chromatography detector comprising a flow cell having an inlet tubular conduit for receiving a liquid chromatographic effluent and discharging it as a flowing columnar stream onto a vertically adjustable receiving surface spaced apart from and located vertically below and in close proximity to the discharge end of the tubular conduit; a receiver adapted to receive liquid overflowing from the receiving surface; an exit conduit for continuously removing liquid from the receiver; a light source for focussing fluorescence-producing light pulses on the flowing columnar stream as it passes from the outlet of the conduit to the receiving surface and a fluorescence detector to detect the produced fluorescence; a source of light pulse for producing acoustic waves in the columnar stream as it passes from the conduit outlet to the receiving surface; and a piezoelectric transducer adapted to detect those waves; and a source of bias voltage applied to the inlet tubular conduit and adapted to produce ionization of the liquid flowing through the flow cell so as to produce photocurrents therein and an electrical system to detect and record the photocurrents. This system is useful in separating and detecting individual chemical compounds from mixtures thereof.

  20. Alien liquid detector and control

    SciTech Connect

    Potter, B.M.

    1980-09-02

    An alien liquid detector employs a monitoring element and an energizing circuit for maintaining the temperature of the monitoring element substantially above ambient temperature. For this purpose an electronic circit controls a flow of heating current to the monitoring element. The presence of an alien liquid is detected by sensing a predetermined change in heating current flow to the monitoring element, e.g., to distinguish between water and oil. In preferred embodiments the monitoring element is a thermistor whose resistance is compared with a reference resistance and heating current through the thermistor is controlled in accordance with the difference. In one embodiment a bridge circuit senses the resistance difference; the difference may be sensed by an operational amplifier arrangement. Features of the invention include positioning the monitoring element at the surface of water, slightly immersed, so that the power required to maintain the thermistor temperature substantially above ambient temperature serves to detect presence of oil pollution at the surface.

  1. Nano bubbles in liquid of a noble-gas mixture.

    PubMed

    Yamamoto, Takenori; Ohnishi, Shuhei

    2010-02-07

    Large-scale molecular dynamics (MD) simulations with over one million atoms are used to investigate nano bubbles in Ar-Ne liquid. The simulations demonstrate cavitations in the stretched liquid, and bubble creation and collapse. We find that a small cavity created in the stretched liquid spontaneously transforms into a nano bubble with the homogeneous vapor region. The equilibrium spherical bubble of 11.4 nm in radius is obtained after the long-time MD run. The surface tension of the nano bubble is found to be larger than that of the flat surface.

  2. Cryogenic liquid-level detector

    NASA Technical Reports Server (NTRS)

    Hamlet, J.

    1978-01-01

    Detector is designed for quick assembly, fast response, and good performance under vibratory stress. Its basic parallel-plate open configuration can be adapted to any length and allows its calibration scale factor to be predicted accurately. When compared with discrete level sensors, continuous reading sensor was found to be superior if there is sloshing, boiling, or other disturbance.

  3. Portable NIR bottled liquid explosive detector

    NASA Astrophysics Data System (ADS)

    Itozaki, Hideo; Ono, Masaki; Ito, Shiori; Uekawa, Keisuke; Miyato, Yuji; Sato-Akaba, Hideo

    2016-05-01

    A near infrared bottled liquid scanner has been developed for security check at airports for anti-terrorism. A compact handheld liquid scanner has been developed using an LED as a light source, instead of a halogen lamp. An LED has much smaller size, longer life time and lower power consumption than those of the lamp. However, it has narrower wave band. Here, we tried to use LEDs to scan liquids and showed the possibility that LEDs can be used as a light source of liquid detector.

  4. Infrared diagnosis using liquid crystal detectors

    NASA Technical Reports Server (NTRS)

    Hugenschmidt, M.; Vollrath, K.

    1986-01-01

    The possible uses of pulsed carbon dioxide lasers for analysis of plasmas and flows need appropriate infrared image converters. Emphasis was placed on liquid crystal detectors and their operational modes. Performance characterstics and selection criteria, such as high sensitivity, short reaction time, and high spatial resolution are discussed.

  5. Liquid Scintillation Detectors for High Energy Neutrinos

    SciTech Connect

    Smith, Stefanie N.; Learned, John G.

    2010-03-30

    Large open volume (not segmented) liquid scintillation detectors have been generally dedicated to low energy neutrino measurements, in the MeV energy region. We describe the potential employment of large detectors (>1 kiloton) for studies of higher energy neutrino interactions, such as cosmic rays and long-baseline experiments. When considering the physics potential of new large instruments the possibility of doing useful measurements with higher energy neutrino interactions has been overlooked. Here we take into account Fermat's principle, which states that the first light to reach each PMT will follow the shortest path between that PMT and the point of origin. We describe the geometry of this process, and the resulting wavefront, which we are calling the 'Fermat surface', and discuss methods of using this surface to extract directional track information and particle identification. This capability may be demonstrated in the new long-baseline neutrino beam from Jaeri accelerator to the KamLAND detector in Japan. Other exciting applications include the use of Hanohano as a movable long-baseline detector in this same beam, and LENA in Europe for future long-baseline neutrino beams from CERN. Also, this methodology opens up the question as to whether a large liquid scintillator detector should be given consideration for use in a future long-baseline experiment from Fermilab to the DUSEL underground laboratory at Homestake.

  6. Neutrino physics with multi-ton scale liquid xenon detectors

    SciTech Connect

    Baudis, L.; Ferella, A.; Kish, A.; Manalaysay, A.; Undagoitia, T. Marrodán; Schumann, M. E-mail: alfredo.ferella@lngs.infn.it E-mail: aaronm@ucdavis.edu E-mail: marc.schumann@lhep.unibe.ch

    2014-01-01

    We study the sensitivity of large-scale xenon detectors to low-energy solar neutrinos, to coherent neutrino-nucleus scattering and to neutrinoless double beta decay. As a concrete example, we consider the xenon part of the proposed DARWIN (Dark Matter WIMP Search with Noble Liquids) experiment. We perform detailed Monte Carlo simulations of the expected backgrounds, considering realistic energy resolutions and thresholds in the detector. In a low-energy window of 2–30 keV, where the sensitivity to solar pp and {sup 7}Be-neutrinos is highest, an integrated pp-neutrino rate of 5900 events can be reached in a fiducial mass of 14 tons of natural xenon, after 5 years of data. The pp-neutrino flux could thus be measured with a statistical uncertainty around 1%, reaching the precision of solar model predictions. These low-energy solar neutrinos will be the limiting background to the dark matter search channel for WIMP-nucleon cross sections below ∼ 2 × 10{sup −48} cm{sup 2} and WIMP masses around 50 GeV⋅c{sup −2}, for an assumed 99.5% rejection of electronic recoils due to elastic neutrino-electron scatters. Nuclear recoils from coherent scattering of solar neutrinos will limit the sensitivity to WIMP masses below ∼ 6 GeV⋅c{sup −2} to cross sections above ∼ 4 × 10{sup −45}cm{sup 2}. DARWIN could reach a competitive half-life sensitivity of 5.6 × 10{sup 26} y to the neutrinoless double beta decay of {sup 136}Xe after 5 years of data, using 6 tons of natural xenon in the central detector region.

  7. Ultrahigh sensitivity heavy noble gas detectors for long-term monitoring and monitoring air. 1998 annual progress report

    SciTech Connect

    Valentine, J.D.; Gross, K.

    1998-06-01

    'The primary objective of this research project is to develop heavy noble gas (krypton, xenon, and radon) detectors for: (1) long-term monitoring of transuranic waste, spent fuel, and other uranium and thorium bearing wastes, and (2) alpha particle air monitors that discriminate between radon emissions and other alpha emitters. A University of Cincinnati/Argonne National Laboratory (UC/ANL) Team has been assembled to complete this detector development project. DOE needs that are addressed by this project include improved long-term monitoring capability and improved air monitoring capability during remedial activities. Successful development and implementation of the proposed detection systems could significantly improve current capabilities with relatively simple and inexpensive equipment. As of June 1, 1998, the UC/ANL Team has: (1) made significant progress toward characterizing the fluid transfer process which is the basis for this detector development project and (2) evaluated several radiation detectors and several potential pulse processing schemes. The following discussion describes the progress made during the first year of this project and the implications of this progress.'

  8. Large-Area Liquid Scintillation Detector Slab

    NASA Astrophysics Data System (ADS)

    Crouch, M. F.; Gurr, H. S.; Hruschka, A. A.; Jenkins, T. L.; Kropp, W. P.; Reines, P.; Sobel, H.

    The following sections are included: * SUMMARY * INTRODUCTION * DETECTOR RESPONSE FUNCTION F(z) AND EVENT POSITION DETERMINATION * REFINEMENTS IN THE DETECTOR CONFIGURATION DESIGN * DETECTOR PERFORMANCE * APPENDIX * REFERENCES

  9. A large area liquid scintillation multiphoton detector

    NASA Astrophysics Data System (ADS)

    Bharadwaj, V. K.; Cain, M. P.; Caldwell, D. O.; Denby, B. H.; Eisner, A. M.; Joshi, U. P.; Kennett, R. G.; Lu, A.; Morrison, R. J.; Pfost, D. R.; Stuber, H. R.; Summers, D. J.; Yellin, S. J.; Appel, J. A.

    1985-01-01

    A 60 layer lead-liquid scintillator shower detector, which we call the SLIC, has been used for multiphoton detection in the Fermilab tagged photon spectrometer. The detector has an unimpeded active area which is 2.44 m by 4.88 m and is segmented, by means of teflon coated channels, into 3.17 cm wide strips. The 60 layers in depth are broken into three directions of alternating readouts so that three position coordinates are determined for each shower. At present the readouts are made by 334 photomultiplier tubes coupled to BBQ doped wavelength shifter bars which integrate the entire depth of the detector. It is relatively straightforward to increase the number of readouts to include longitudinal segmentation and to increase the segmentation of the outer region which are at present read out two strips to a readout. The energy and position resolutions of isolated showers are about {12%}/{√E} and 3 mm., respectively. The SLIC has been used to study the K-π+π0 decay of the D 0 [1], as well as for electron and muon identification in ψ → e +e - and ψ → μ+μ- plus π0 identification in γp → ψχ [8].

  10. Spillage detector for liquid chromatography systems

    NASA Technical Reports Server (NTRS)

    Jarvis, M. J.; Fulton, D. S. (Inventor)

    1986-01-01

    A spillage detector device for use in conjunction with fractionation of liquid chromatography systems which includes a spillage recieving enclosure beneath the fractionation area is described. A sensing device having a plurality of electrodes of alternating polarity is mounted within the spillage recieving enclosure. Detection circuitry, responsive to conductivity between electrodes, is operatively connected to the sensing device. The detection circuitry feeds into the output circuitry. The output circuit has relaying and switching circuitry directed to a solenoid, an alarm system and a pump. The solenoid is connected to the pliable conduit of the chromatography system. The alarm system comprises an audio alarm and a visual signal. A 115-volt power system interconnected with the pump, the solenoid, the sensing device, and the detection and output circuitry.

  11. Ageing studies of TPB in noble gas detectors for dark matter and neutrinoless ββ decay searches.

    PubMed

    Yahlali, N; Garcia, J M; Díaz, J; Soriano, A; Fernandes, L M P

    2017-02-05

    Noble gases (Xe, Ar, Kr) are very attractive as detector media in Dark Matter search and neutrinoless double-beta decay experiments. However, the detection of their scintillation light (in the VUV spectral region) requires shifting the VUV light to visible light, where standard photosensors are more efficient. Tetraphenyl butadiene (TPB) is widely used as wavelength shifter, absorbing the VUV light and re-emitting in the blue region (~430nm). TPB is an organic molecule that may degrade due to exposure to environmental agents and also to ultraviolet light. In this work, we present TPB ageing studies due to exposure to VUV light, aiming at quantifying the reduction of the absolute fluorescence yield of TPB coatings of several thicknesses (130nm, 260nm, 390nm, 1600nm), exposed to various doses of VUV light at 170nm (similar to the Xe scintillation). In our setup, the VUV light is produced from a vacuum monochromator coupled to a deuterium lamp. The VUV exposure in our setup is compared to the exposure obtained in the electroluminescent gaseous Xe TPC of the NEXT-100 experiment for neutrinoless double-beta decay search.

  12. Ageing studies of TPB in noble gas detectors for dark matter and neutrinoless ββ decay searches

    NASA Astrophysics Data System (ADS)

    Yahlali, N.; Garcia, J. M.; Díaz, J.; Soriano, A.; Fernandes, L. M. P.

    2017-02-01

    Noble gases (Xe, Ar, Kr) are very attractive as detector media in Dark Matter search and neutrinoless double-beta decay experiments. However, the detection of their scintillation light (in the VUV spectral region) requires shifting the VUV light to visible light, where standard photosensors are more efficient. Tetraphenyl butadiene (TPB) is widely used as wavelength shifter, absorbing the VUV light and re-emitting in the blue region ( 430 nm). TPB is an organic molecule that may degrade due to exposure to environmental agents and also to ultraviolet light. In this work, we present TPB ageing studies due to exposure to VUV light, aiming at quantifying the reduction of the absolute fluorescence yield of TPB coatings of several thicknesses (130 nm, 260 nm, 390 nm, 1600 nm), exposed to various doses of VUV light at 170 nm (similar to the Xe scintillation). In our setup, the VUV light is produced from a vacuum monochromator coupled to a deuterium lamp. The VUV exposure in our setup is compared to the exposure obtained in the electroluminescent gaseous Xe TPC of the NEXT-100 experiment for neutrinoless double-beta decay search.

  13. One-step facile synthesis of noble metal nanocrystals with tunable morphology in a nematic liquid crystalline medium

    NASA Astrophysics Data System (ADS)

    Dan, Kaustabh; Satpati, Biswarup; Datta, Alokmay

    2016-05-01

    The present study describes in-situ synthesis of noble metal nano structures (MNCs) (Au and Ag) within a nematic liquid crystalline medium MBBA [N-(4-methoxybenzylidene)-4-butylaniline] without using any seed mediated growth protocol or without using any external stabilizing or reducing agent. Detailed Transmission Electron Microscopy (TEM) study indicates that apart from Kinetic based mechanism, the thermodynamical parameters also influence greatly the morphological evolution of these MNCs. The MNCs are of diverse shapes including nano prisms, hexagons, urchins, cubes, and rods which depend on the time of reaction and the choice of nanoparticle precursor.

  14. Liquid xenon detectors for particle physics and astrophysics

    SciTech Connect

    Aprile, E.; Doke, T.

    2010-07-15

    This article reviews the progress made over the last 20 years in the development and applications of liquid xenon detectors in particle physics, astrophysics, and medical imaging experiments. A summary of the fundamental properties of liquid xenon as radiation detection medium, in light of the most current theoretical and experimental information is first provided. After an introduction of the different type of liquid xenon detectors, a review of past, current, and future experiments using liquid xenon to search for rare processes and to image radiation in space and in medicine is given. Each application is introduced with a survey of the underlying scientific motivation and experimental requirements before reviewing the basic characteristics and expected performance of each experiment. Within this decade it appears likely that large volume liquid xenon detectors operated in different modes will contribute to answering some of the most fundamental questions in particle physics, astrophysics, and cosmology, fulfilling the most demanding detection challenges. From detectors based solely on liquid xenon (LXe) scintillation, such as in the MEG experiment for the search of the rare ''{mu}{yields}e{gamma}'' decay, currently the largest liquid xenon detector in operation, and in the XMASS experiment for dark matter detection, to the class of time projection chambers which exploit both scintillation and ionization of LXe, such as in the XENON dark matter search experiment and in the Enriched Xenon Observatory for neutrinoless double beta decay, unrivaled performance and important contributions to physics in the next few years are anticipated.

  15. A liquid Xenon detector for micro-PET

    NASA Astrophysics Data System (ADS)

    Retière, F.

    2010-11-01

    Liquid Xenon is a very promising technology for the new generation of Positron Emission Tomography detectors. The performance achieved by combining both scintillation light and ionization charge readout significantly exceeds the capabilities of conventional crystal based detectors. In these proceedings, we show that we achieved a 9.6% (full width half maximum) for 511 keV photons by combining light and charge. Then, we investigate the performance of a liquid Xenon micro-PET detector by running simulations and relying on a Compton reconstruction algorithm. The image quality is far superior to the existing FOCUS 120 micro-PET.

  16. A simple liquid detector for radiopharmaceutical processing systems

    SciTech Connect

    Alexoff, D.L.; Hallaba, K.; Schlyer, D.; Ferrieri, R.

    1995-03-01

    Sensing the presence of liquids in tubing and vessels in radiochemical processing equipment provides information important to the remote or automatic control of the production of clinical doses of radiopharmaceuticals. Although modern commercial automated radiopharmaceutical synthesis machines do not usually include liquid presence as a measured process variable, earlier more complex automated synthesis devices did; and the inclusion of such feedback can increase system reliability and simplify trouble-shooting tasks carried out by computer software or human operators. Commercial liquid level detectors are often designed for large-scale industrial processes and are therefore too large or expensive to be useful in many radiochemical hardware systems. An inexpensive miniature optical liquid detector originally by Kramer and Fuchs has been duplicated here for use in monitoring the presence of liquids in teflon tubing (1/16 in. O.D.) in an enriched oxygen-18 water recovery system.

  17. Rayleigh scattering of linear alkylbenzene in large liquid scintillator detectors.

    PubMed

    Zhou, Xiang; Liu, Qian; Wurm, Michael; Zhang, Qingmin; Ding, Yayun; Zhang, Zhenyu; Zheng, Yangheng; Zhou, Li; Cao, Jun; Wang, Yifang

    2015-07-01

    Rayleigh scattering poses an intrinsic limit for the transparency of organic liquid scintillators. This work focuses on the Rayleigh scattering length of linear alkylbenzene (LAB), which will be used as the solvent of the liquid scintillator in the central detector of the Jiangmen Underground Neutrino Observatory. We investigate the anisotropy of the Rayleigh scattering in LAB, showing that the resulting Rayleigh scattering length will be significantly shorter than reported before. Given the same overall light attenuation, this will result in a more efficient transmission of photons through the scintillator, increasing the amount of light collected by the photosensors and thereby the energy resolution of the detector.

  18. Rayleigh scattering of linear alkylbenzene in large liquid scintillator detectors

    SciTech Connect

    Zhou, Xiang Zhang, Zhenyu; Liu, Qian; Zheng, Yangheng; Wurm, Michael; Zhang, Qingmin; Ding, Yayun; Zhou, Li; Cao, Jun; Wang, Yifang

    2015-07-15

    Rayleigh scattering poses an intrinsic limit for the transparency of organic liquid scintillators. This work focuses on the Rayleigh scattering length of linear alkylbenzene (LAB), which will be used as the solvent of the liquid scintillator in the central detector of the Jiangmen Underground Neutrino Observatory. We investigate the anisotropy of the Rayleigh scattering in LAB, showing that the resulting Rayleigh scattering length will be significantly shorter than reported before. Given the same overall light attenuation, this will result in a more efficient transmission of photons through the scintillator, increasing the amount of light collected by the photosensors and thereby the energy resolution of the detector.

  19. Fiber Optic Detector For Liquid Chemical Leaks

    NASA Astrophysics Data System (ADS)

    Luukkala, Mauri; Raatikainen, Pekka; Salo, Olli

    1989-10-01

    This paper describes a simple and economical sensor which employs fiber optics to detect the presence of hazardous liquid chemicals, particularly undiluted hydrocarbons. The device is best suited to monitor the interstitial space of double walled underground storage tanks. Because the sensor is plastic and is situated at the end of a passive and insulating optical fiber the sensor can be considered inherently safe. The optical fiber used for this device can be up to several hundred meters long.

  20. Temperature-dependence of phonons, solid state properties and liquid structure of noble metals: A comparison of pair-potentials

    NASA Astrophysics Data System (ADS)

    Januszko, A.; Bose, S. K.

    2015-02-01

    Two groups of effective pair-potentials are studied from the viewpoint of their suitability in being able to describe solid state properties and liquid state structure of noble metals Cu, Ag and Au over a wide temperature range. Since the effective pair-potentials are usually empirical in nature, with parameters obtained by fitting to some reference state properties, the objective of the present study is to determine whether a particular parametrization scheme has any definite advantage over another. We consider Morse potentials with parameters determined by equilibrium lattice parameter, cohesive/sublimation energies as well as bulk modulus values of the solid at low/room temperatures. The other group of potentials considered is Erkoç potentials, where the parameters were determined first by studying dimers and further modified using bulk stability condition and bulk cohesive energy values. The potentials were then used to study the energetics of microclusters containing 3-7 atoms. Quasiharmonic results for the solid obtained at different temperatures and Monte Carlo simulation for the liquid state show that phonon spectra, thermal expansion, temperature-dependence of specific heats and liquid structure are much better described by the latter group. The first group of potentials may have an advantage in reproducing the temperature-dependence of elastic constants and bulk moduli, since they are based on room temperature values of these properties, which show only weak temperature-dependence in general for all metals. It is argued that potentials based on parameters fitted to the properties at a single volume are less versatile in capturing the temperature-dependence of various thermodynamic properties over a wide range. Potentials capable of reproducing the energetics of clusters of different co-ordination numbers and volumes per atom may fare better in this regard.

  1. a Theoretical Model of a Superheated Liquid Droplet Neutron Detector.

    NASA Astrophysics Data System (ADS)

    Harper, Mark Joseph

    Neutrons can interact with the atoms in superheated liquid droplets which are suspended in a viscous matrix material, resulting in the formation of charged recoil ions. These ions transfer energy to the liquid, sometimes resulting in the droplets vaporizing and producing observable bubbles. Devices employing this mechanism are known as superheated liquid droplet detectors, or bubble detectors. The basis of bubble detector operation is identical to that of bubble chambers, which have been well characterized by researchers such as Wilson, Glaser, Seitz, and others since the 1950's. Each of the microscopic superheated liquid droplets behaves like an independent bubble chamber. This dissertation presents a theoretical model which considers the three principal aspects of detector operation: nuclear reactions, charged particle energy deposition, and thermodynamic bubble formation. All possible nuclear reactions were examined and those which could reasonably result in recoil ions sufficiently energetic to vaporize a droplet were analyzed in detail. Feasible interactions having adequate cross sections include elastic and inelastic scattering, n-proton, and n-alpha reactions. Ziegler's TRansport of Ions in Matter (TRIM) code was used to calculate the ions' stopping powers in various compounds based on the ionic energies predicted by standard scattering distributions. If the ions deposit enough energy in a small enough volume then the entire droplet will vaporize without further energy input. Various theories as to the vaporization of droplets by ionizing radiation were studied and a novel method of predicting the critical (minimum) energy was developed. This method can be used to calculate the minimum required stopping power for the ion, from which the threshold neutron energy is obtainable. Experimental verification of the model was accomplished by measuring the response of two different types of bubble detectors to monoenergetic thermal neutrons, as well as to neutrons

  2. Optical scattering lengths in large liquid-scintillator neutrino detectors

    SciTech Connect

    Wurm, M.; Feilitzsch, F. von; Goeger-Neff, M.; Hofmann, M.; Lewke, T.; Meindl, Q.; Moellenberg, R.; Oberauer, L.; Potzel, W.; Tippmann, M.; Todor, S.; Winter, J.; Lachenmaier, T.; Traunsteiner, C.; Undagoitia, T. Marrodan

    2010-05-15

    For liquid-scintillator neutrino detectors of kiloton scale, the transparency of the organic solvent is of central importance. The present paper reports on laboratory measurements of the optical scattering lengths of the organic solvents phenylxylylethane, linear alkylbenzene (LAB), and dodecane, which are under discussion for next-generation experiments such as SNO+ (Sudbury Neutrino Observatory), HanoHano, or LENA (Low Energy Neutrino Astronomy). Results comprise the wavelength range of 415-440 nm. The contributions from Rayleigh and Mie scattering as well as from absorption/re-emission processes are discussed. Based on the present results, LAB seems to be the preferred solvent for a large-volume detector.

  3. Optical scattering lengths in large liquid-scintillator neutrino detectors.

    PubMed

    Wurm, M; von Feilitzsch, F; Göger-Neff, M; Hofmann, M; Lachenmaier, T; Lewke, T; Marrodán Undagoitia, T; Meindl, Q; Möllenberg, R; Oberauer, L; Potzel, W; Tippmann, M; Todor, S; Traunsteiner, C; Winter, J

    2010-05-01

    For liquid-scintillator neutrino detectors of kiloton scale, the transparency of the organic solvent is of central importance. The present paper reports on laboratory measurements of the optical scattering lengths of the organic solvents phenylxylylethane, linear alkylbenzene (LAB), and dodecane, which are under discussion for next-generation experiments such as SNO+ (Sudbury Neutrino Observatory), HanoHano, or LENA (Low Energy Neutrino Astronomy). Results comprise the wavelength range of 415-440 nm. The contributions from Rayleigh and Mie scattering as well as from absorption/re-emission processes are discussed. Based on the present results, LAB seems to be the preferred solvent for a large-volume detector.

  4. Performance of liquid xenon gamma ray detector for MEG

    NASA Astrophysics Data System (ADS)

    Sawada, Ryu

    2010-11-01

    MEG experiment searches for a rare muon decay (μ+ →e+ γ) at PSI in Switzerland. A physics run to take large amount of data was started at the end of summer in 2008. MEG will have a sensitivity around predicted branching ratio by new theories beyond the standard model. In order to discriminate signal events from backgrounds, precise measurement of energy, emission angle and time is important. The gamma ray detector of the experiment is a scintillation detector utilizing 900 litters of liquid xenon and 846 photo-multiplier tubes. The photon yield of xenon is high and the decay time is fast. Because of these properties, the detector has good energy, position and time resolutions. The construction of the gamma ray detector was completed in 2007. The control of the transfer and purification system of xenon and the operation of the detector worked successfully. In 2008, calibration of the detector was done in one month by using gamma rays from neutral pion decays. During the calibration run, resolutions for energy, position and time were measured and calibration parameters for reconstruction algorithms were obtained. During the physics run, variation of light yield due to purification was observed. The variation was well monitored by using several light sources.

  5. Modeling Electronegative Impurity Concentrations in Liquid Argon Detectors

    NASA Astrophysics Data System (ADS)

    Tang, Wei; Li, Yichen; Thorn, Craig; Qian, Xin

    2017-01-01

    Achieving long electron lifetime is crucial to reach the high performance of large Liquid Argon Time Projection Chamber (LArTPC) envisioned for next generation neutrino experiments. We have built up a quantitative model to describe the impurity distribution and transportation in a cryostat. Henrys constants of Oxygen and water, which describe the partition of impurities between gas argon and liquid argon, have been deduced through this model with the measurements in BNL 20-L LAr test stand. These results indicate the importance of the gas purification system and prospects on large LArTPC detectors will be discussed.

  6. Developing Detectors for Scintillation Light in Liquid Argon for DUNE

    SciTech Connect

    Howard, Bruce

    2016-12-22

    The Deep Underground Neutrino experiment will conduct a broad program of physics research by studying a beam of neutrinos from Fermilab, atmospheric neutrinos, neutrinos from potential supernovae, and potential nucleon decay events. In pursuit of these studies, the experiment will deploy four 10kt fiducial mass liquid argon time projection chambers underground in Lead, South Dakota. Liquid argon time projection chambers allow high-resolution tracking and energy measurements. A precise timing signal is needed to provide the necessary time stamp to localize events in the drift direction. As liquid argon is a natural scintillator, a photon detection system will be deployed to provide such a signal, especially for non-beam events. In the baseline design for the single-phase time projection chamber, the detectors are contained within the anode plane assemblies. The design of two prototypes utilizing wavelength shifters and light guides are presented, and aspects of the research and development program are discussed.

  7. Development of liquid xenon detectors for gamma ray astronomy

    NASA Technical Reports Server (NTRS)

    Aprile, Elena; Suzuki, Masayo

    1989-01-01

    The application of liquid xenon in high-resolution detectors for gamma-ray astronomy is being investigated. Initial results from a pulse-shape analysis of ionization signals in a liquid-xenon gridded chamber indicate that it is possible to achieve the necessary liquid purity for the transport of free electrons with simple techniques. The energy resolution has been measured as a function of applied electric field, using electrons and gamma-rays from a 207Bi source. At a field of 12 kV/cm the noise-substracted energy resolution of the dominant 569-keV gamma-ray line is 34 keV FWHM (full width at half maximum). This value is mostly determined by recombination of electron-ion pairs on delta-electron tracks.

  8. Organic liquid scintillation detector shape and volume impact on radiation portal monitors

    NASA Astrophysics Data System (ADS)

    Paff, Marc G.; Clarke, Shaun D.; Pozzi, Sara A.

    2016-07-01

    We have developed and tested a radiation portal monitor using organic liquid scintillation detectors. In order to optimize our system designs, neutron measurements were carried out with three organic liquid scintillation detectors of different shapes and sizes, along with a 3He radiation portal monitor (RPM) as a reference. The three liquids tested were a 7.62 cm diameter by 7.62 cm length cylindrical active volume organic liquid scintillation detector, a 12.7 cm diameter by 12.7 cm length cylindrical active volume organic liquid scintillation detector, and a 25 cm by 25 cm by 10 cm "paddle" shaped organic liquid scintillation detector. Background and Cf-252 neutron measurements were recorded to allow for a comparison of neutron intrinsic efficiencies as well as receiver operating characteristics (ROC) curves between detectors. The 12.7 cm diameter cylindrical active volume organic liquid scintillation detector exhibited the highest intrinsic neutron efficiency (54%) of all three liquid scintillators. An ROC curve analysis for a heavily moderated Cf-252 measurement showed that using the 12.7 cm diameter by 12.7 cm length cylindrical active volume Eljen EJ309 organic liquid scintillation detector would result in the fewest needed detector units in order to achieve a near 100% positive neutron alarm rate while maintaining a better than 1 in 10,000 false alarm rate on natural neutron background. A small number of organic liquid scintillation detectors could therefore be a valid alternative to 3He in some RPM applications.

  9. Dark matter sensitivity of multi-ton liquid xenon detectors

    SciTech Connect

    Schumann, Marc; Bütikofer, Lukas; Baudis, Laura; Kish, Alexander; Selvi, Marco E-mail: lbaudis@physik.uzh.ch E-mail: alexkish@physik.uzh.ch

    2015-10-01

    We study the sensitivity of multi ton-scale time projection chambers using a liquid xenon target, e.g., the proposed DARWIN instrument, to spin-independent and spin-dependent WIMP-nucleon scattering interactions. Taking into account realistic backgrounds from the detector itself as well as from neutrinos, we examine the impact of exposure, energy threshold, background rejection efficiency and energy resolution on the dark matter sensitivity. With an exposure of 200 t × y and assuming detector parameters which have been already demonstrated experimentally, spin-independent cross sections as low as 2.5 × 10{sup −49} cm{sup 2} can be probed for WIMP masses around 40 GeV/c{sup 2}. Additional improvements in terms of background rejection and exposure will further increase the sensitivity, while the ultimate WIMP science reach will be limited by neutrinos scattering coherently off the xenon nuclei.

  10. Noble Gases

    NASA Astrophysics Data System (ADS)

    Podosek, F. A.

    2003-12-01

    The noble gases are the group of elements - helium, neon, argon, krypton, xenon - in the rightmost column of the periodic table of the elements, those which have "filled" outermost shells of electrons (two for helium, eight for the others). This configuration of electrons results in a neutral atom that has relatively low electron affinity and relatively high ionization energy. In consequence, in most natural circumstances these elements do not form chemical compounds, whence they are called "noble." Similarly, much more so than other elements in most circumstances, they partition strongly into a gas phase (as monatomic gas), so that they are called the "noble gases" (also, "inert gases"). (It should be noted, of course, that there is a sixth noble gas, radon, but all isotopes of radon are radioactive, with maximum half-life a few days, so that radon occurs in nature only because of recent production in the U-Th decay chains. The factors that govern the distribution of radon isotopes are thus quite different from those for the five gases cited. There are interesting stories about radon, but they are very different from those about the first five noble gases, and are thus outside the scope of this chapter.)In the nuclear fires in which the elements are forged, the creation and destruction of a given nuclear species depends on its nuclear properties, not on whether it will have a filled outermost shell when things cool off and nuclei begin to gather electrons. The numerology of nuclear physics is different from that of chemistry, so that in the cosmos at large there is nothing systematically special about the abundances of the noble gases as compared to other elements. We live in a very nonrepresentative part of the cosmos, however. As is discussed elsewhere in this volume, the outstanding generalization about the geo-/cosmochemistry of the terrestrial planets is that at some point thermodynamic conditions dictated phase separation of solids from gases, and that the

  11. Noble Gases in Iddingsite from the Lafayette Meteorite: Evidence for Liquid Water on Mars in the Last Few Hundred Million Years

    NASA Technical Reports Server (NTRS)

    Swindle, T. D.; Treiman, A. H.; Lindstrom, D. J.; Brkland, M. K.; Cohen, B. A.; Grier, J. A.; Li, B.; Olson, E. K.

    2000-01-01

    We analyzed noble gases from 18 samples of weathering products ("iddingsite") from the Lafayette meteorite. Potassium-argon ages of 12 samples range from near zero to 670 +/- 91 Ma. These ages confirm the martian origin of the iddingsite, but it is not clear whether any or all of the ages represent iddingsite formation as opposed to later alteration or incorporation of martian atmospheric Ar-40. In any case, because iddingsite formation requires liquid water, this data requires the presence of liquid water near the surface of Mars at least as recently as 1300 Ma ago, and probably as recently as 650 Ma ago. Krypton and Xe analysis of a single 34 microg sample indicates the presence of fractionated martian atmosphere within the iddingsite. This also confirms the martian origin of the iddingsite. The mechanism of incorporation could either be through interaction with liquid water during iddingsite formation or a result of shock implantation of adsorbed atmospheric gas.

  12. Fiber Bragg grating photoacoustic detector for liquid chromatography.

    PubMed

    Yang, Qingxin; Loock, Hans-Peter; Kozin, Igor; Pedersen, David

    2008-11-01

    Fiber Bragg Gratings (FBGs) are known to be sensitive acoustic transducers and have previously been used for the photoacoustic detection of small solid samples. Here, we demonstrate the use of an FBG as an on-line detector for liquid chromatography. The FBG was inserted into a silica capillary and the photoacoustic response from the effluent was generated by a 10 ns pulsed laser. The acoustic pulse was quantified by the FBG through a characteristic change in the reflection spectrum. Good repeatability and linear response were obtained over three orders of magnitude (R(2) > 0.99), and the limit of detection of Coumarin 440 was determined to be 5 microM. The technique was successfully coupled to high performance liquid chromatography and applied to on-line analysis of a three-compound solution. Photoacoustic detection in liquid chromatography using FBGs is a label-free method, which can be applied to the detection of any chromogenic compound irrespective of its fluorogenic properties. It is a simple, inexpensive, and inherently micron-sized technique, insensitive to electromagnetic interference.

  13. Development of a Liquefied Noble Gas Time Projection Chamber

    NASA Astrophysics Data System (ADS)

    Lesser, Ezra; White, Aaron; Aidala, Christine

    2015-10-01

    Liquefied noble gas detectors have been used for various applications in recent years for detecting neutrinos, neutrons, photons, and potentially dark matter. The University of Michigan is developing a detector with liquid argon to produce scintillation light and ionization electrons. Our data collection method will allow high-resolution energy measurement and spatial reconstruction of detected particles by using multi-pixel silicon photomultipliers (SiPM) and a cylindrical time projection chamber (TPC) with a multi-wire endplate. We have already designed a liquid argon condenser and purification unit surrounded by an insulating vacuum, constructed circuitry for temperature and pressure sensors, and created software to obtain high-accuracy sensor readouts. The status of detector development will be presented. Funded through the Michigan Memorial Phoenix Project.

  14. Energy Resolution of a Large-Scale Liquid Argon Detector

    NASA Astrophysics Data System (ADS)

    Wood, Kevin; Mishra, Sanjib; LBNE Collaboration

    2015-04-01

    The high granularity and feasibility of large-scale construction makes the Liquid Argon Time Projection Chamber (LArTPC) a suitable technology for the Long Baseline Neutrino Experiment (LBNE) far detector. Particle identification relies largely on the topology and calorimetric information from the signature left in the detector. The measurements LBNE intends to make depend on accurately distinguishing charged current electron neutrino events from neutral current background events. A neutrino event featuring an electron produced by νe interaction will tag it as signal; although, gammas from π0 decays in neutral current events induce electromagnetic showers that resemble those of an electron. The granularity and high energy resolution of LArTPCs enable dE/dx to be extracted from the beginning of these showers which helps separate gammas from electrons and, ultimately, charged current electron neutrino events from neutral current events. Presented here is an estimation of the technology's energy resolution and a demonstration of its capabilities for separating electrons and gammas using dE/dx. Sanjib works closely with Kevin on the presented material.

  15. Determination of Total Body Radioactivity Using Liquid Scintillation Detectors

    NASA Astrophysics Data System (ADS)

    Reines, F.; Schuch, R. L.; Cowan, C. L.; Harrison, F. B.; Anderson, E. C.; Hayes, F. N.

    IN the course of developing equipment for other problems1, we have made some measurements of the total radioactivity content of several humans and a dog, using a technique which may have other applications in biophysics. The equipment used consists of a liquid scintillation detector in the shape of a cylinder 30 in. in diameter and 30 in. high, surrounded by RCA type 5819 photomultipliers, fortyfive of which were used in these measurements. Cylindrical steel inserts, 14 in. in diameter in one case and 20 in. in diameter in another, 32 in. high and 0.015 in. thick, were placed in the tank, leaving an annular region filled with liquid scintillator (toluene-terphenyl-α-naphthyl phenyl oxazole). A lead shield 5 in. thick was placed around the assembly, leaving only the top of the insert open. The fortyfive photomultipliers were connected in parallel and their output fed through a linear amplifier to a tenchannel pulse-height analyser (see Fig. 1)…

  16. Preliminary study of the inclusion of Water-based Liquid Scintillator in the WATCHMAN Detector

    SciTech Connect

    Sweany, Melinda; Feng, Patrick L.; Marleau, Peter

    2015-02-01

    This note summarizes an effort to characterize the effects of adding water-based liquid scintillator to the WATCHMAN detector. A detector model was built in the Geant4 Monte Carlo toolkit, and the position reconstruction of positrons within the detector was compared with and without scintillator. This study highlights the need for further modeling studies and small-scale experimental studies before inclusion into a large-scale detector, as the benefits compared to the associated costs are unclear.

  17. Characterization of a cubic EJ-309 liquid scintillator detector

    NASA Astrophysics Data System (ADS)

    Tomanin, A.; Paepen, J.; Schillebeeckx, P.; Wynants, R.; Nolte, R.; Lavietes, A.

    2014-08-01

    A cubic EJ-309 liquid scintillator of 10 cm width has been characterized for its response to γ-rays and neutrons. Response functions to γ-rays were measured with calibrated radionuclide γ-ray sources in the energy range from 400 keV to 6 MeV. Response functions for neutrons were obtained from measurements at the PTB Van de Graaff accelerator with quasi-monoenergetic neutron beams in the energy range from 500 keV to 2.7 MeV, and at the PTB cyclotron with time-of-flight (TOF) measurements in the energy range from 2.5 to 14 MeV. The light output and resolution functions for electrons and protons were derived by a least squares adjustment to experimental data using theoretical response functions determined with Monte Carlo simulations. The simulated response function for neutron was validated by results of measurements with an AmBe neutron source which was characterized for its total neutron intensity. The results indicate that the cubic EJ-309 detector is suitable for use in mixed γ-ray and neutron fields.

  18. An investigation of the background electron emissions in the LUX detector

    NASA Astrophysics Data System (ADS)

    Xu, Jingke; LUX Collaboration

    2016-03-01

    Dual phase noble liquid detectors have demonstrated exceptional capability towards rare event detection. However, the ultimate sensitivity of such detectors at very low energies is limited by the emission of delayed ionization electrons and of uncorrelated spontaneous background electrons, generated by a variety of physical mechanisms, and originating from both the bulk liquid and detector surfaces. Using the LUX detector as an example, I will present an investigation of the different electron emission phenomena in Xe TPCs at different time scales since previous energy depositions in the detector, and attempt to identify the sources of these electrons. I will also discuss the relevance of this study for noble liquid physics and for the characterization of Xe TPC detectors.

  19. Structural design of a high energy particle detector using liquid scintillator

    SciTech Connect

    Berg, Timothy John; /Minnesota U.

    1997-02-01

    This thesis presents a design for a 10,000 ton liquid scintillator neutrino detector being considered for the MINOS project at Fermilab. Details of designing, manufacturing, and assembling the active detector components are presented. The detector consists of 1080 magnetized steel absorber planes alternating with 1080 active detector planes. Each active plane is made up of plastic extrusions divided into nearly 400 cells for positional resolution. Life tests on the plastic extrusions determine their feasibility for containing the scintillator. The extrusions are sealed at the bottom, filled with liquid scintillator, and have an optical fiber running the entire length of each cell. The fibers terminate at the top of each extrusion in a manifold. An optical-fiber-light-guide connects the fibers in each manifold to a photo-detector. The photo-detector converts the light signals from the scintillator and optical fibers into electrical impulses for computer analysis.

  20. Double phase (liquid/gas) xenon scintillation detector for WIMPs direct search

    NASA Astrophysics Data System (ADS)

    Yamashita, M.; Doke, T.; Kikuchi, J.; Suzuki, S.

    2003-10-01

    A double phase (liquid/gas) xenon prototype detector of a 0.3 l active volume for WIMPs direct search has been constructed and tested. Proportional scintillation signals are observed by a multi-wire anode mounted in gas phase after ionization electrons drifted successfully long distance in liquid xenon. Both direct and proportional scintillation were used to discriminate electron recoil from nuclear recoil. Basic performances of the detector and the rejection efficiency of background gamma rays were demonstrated.

  1. Experimental partitioning of Zr, Ti, and Nb between silicate liquid and a complex noble metal alloy and the partitioning of Ti between perovskite and platinum metal

    NASA Technical Reports Server (NTRS)

    Jurewicz, Stephen R.; Jones, John H.

    1993-01-01

    El Goresy et al.'s observation of Nb, Zr, and Ta in refractory platinum metal nuggets (RPMN's) from Ca-Al-rich inclusions (CAI's) in the Allende meteorite led them to propose that these lithophile elements alloyed in the metallic state with noble metals in the early solar nebula. However, Grossman pointed out that the thermodynamic stability of Zr in the oxide phase is vastly greater than metallic Zr at estimated solar nebula conditions. Jones and Burnett suggested this discrepancy may be explained by the very non-ideal behavior of some lithophile transition elements in noble metal solutions and/or intermetallic compounds. Subsequently, Fegley and Kornacki used thermodynamic data taken from the literature to predict the stability of several of these intermetallic compounds at estimated solar nebula conditions. Palme and Schmitt and Treiman et al. conducted experiments to quantify the partitioning behavior of certain lithophile elements between silicate liquid and Pt-metal. Although their results were somewhat variable, they did suggest that Zr partition coefficients were too small to explain the observed 'percent' levels in some RPMN's. Palme and Schmitt also observed large partition coefficients for Nb and Ta. No intermetallic phases were identified. Following the work of Treiman et al., Jurewicz and Jones performed experiments to examine Zr, Nb, and Ti partitioning near solar nebula conditions. Their results showed that Zr, Nb, and Ti all have an affinity for the platinum metal, with Nb and Ti having a very strong preference for the metal. The intermetallic phases (Zr,Fe)Pt3, (Nb,Fe)Pt3, and (Ti,Fe)Pt3 were identified. Curiously, although both experiments and calculations indicate that Ti should partition strongly into Pt-metal (possibly as TiPt3), no Ti has ever been observed in any RPMN's. Fegley and Kornacki also noticed this discrepancy and hypothesized that the Ti was stabilized in perovskite which is a common phase in Allende CAI's.

  2. CONDENSED MATTER: ELECTRONIC STRUCTURE, ELECTRICAL, MAGNETIC, AND OPTICAL PROPERTIES: Study of Thermodynamics of Liquid Noble-Metals Alloys Through a Pseudopotential Theory

    NASA Astrophysics Data System (ADS)

    Vora, Aditya M.

    2010-09-01

    The Gibbs-Bogoliubov (GB) inequality is applied to investigate the thermodynamic properties of some equiatomic noble metal alloys in liquid phase such as Au-Cu, Ag-Cu, and Ag-Au using well recognized pseudopotential formalism. For description of the structure, well known Percus-Yevick (PY) hard sphere model is used as a reference system. By applying a variation method the best hard core diameters have been found which correspond to minimum free energy. With this procedure the thermodynamic properties such as entropy and heat of mixing have been computed. The influence of local field correction function viz; Hartree (H), Taylor (T), Ichimaru-Utsumi (IU), Farid et al. (F), and Sarkar et al. (S) is also investigated. The computed results of the excess entropy compares favourably in the case of liquid alloys while the agreement with experiment is poor in the case of heats of mixing. This may be due to the sensitivity of the heats of mixing with the potential parameters and the dielectric function.

  3. Self-shielding effect of a single phase liquid xenon detector for direct dark matter search

    NASA Astrophysics Data System (ADS)

    Minamino, A.; Abe, K.; Ashie, Y.; Hosaka, J.; Ishihara, K.; Kobayashi, K.; Koshio, Y.; Mitsuda, C.; Moriyama, S.; Nakahata, M.; Nakajima, Y.; Namba, T.; Ogawa, H.; Sekiya, H.; Shiozawa, M.; Suzuki, Y.; Takeda, A.; Takeuchi, Y.; Taki, K.; Ueshima, K.; Ebizuka, Y.; Ota, A.; Suzuki, S.; Hagiwara, H.; Hashimoto, Y.; Kamada, S.; Kikuchi, M.; Kobayashi, N.; Nagase, T.; Nakamura, S.; Tomita, K.; Uchida, Y.; Fukuda, Y.; Sato, T.; Nishijima, K.; Maruyama, T.; Motoki, D.; Itow, Y.; Kim, Y. D.; Lee, J. I.; Moon, S. H.; Lim, K. E.; Cravens, J. P.; Smy, M. B.; The Xmass Collaboration

    2012-05-01

    Liquid xenon is a suitable material for a dark matter search. For future large scale experiments, single phase detectors are attractive due to their simple configuration and scalability. However, in order to reduce backgrounds, they need to fully rely on liquid xenon's self-shielding property. A prototype detector was developed at Kamioka Observatory to establish vertex and energy reconstruction methods and to demonstrate the self-shielding power against γ-rays from outside of the detector. 662 keV γ-rays from 137Cs are attenuated by a factor of about 50 over a distance of 20 cm.

  4. Fast range measurement of spot scanning proton beams using a volumetric liquid scintillator detector

    PubMed Central

    Hui, CheukKai; Robertson, Daniel; Alsanea, Fahed; Beddar, Sam

    2016-01-01

    Accurate confirmation and verification of the range of spot scanning proton beams is crucial for correct dose delivery. Current methods to measure proton beam range using ionization chambers are either time-consuming or result in measurements with poor spatial resolution. The large-volume liquid scintillator detector allows real-time measurements of the entire dose profile of a spot scanning proton beam. Thus, liquid scintillator detectors are an ideal tool for measuring the proton beam range for commissioning and quality assurance. However, optical artefacts may decrease the accuracy of measuring the proton beam range within the scintillator tank. The purpose of the current study was to 1) develop a geometric calibration system to accurately calculate physical distances within the liquid scintillator detector, taking into account optical artefacts; and 2) assess the accuracy, consistency, and robustness of proton beam range measurement using the liquid scintillator detector with our geometric calibration system. The range of the proton beam was measured with the calibrated liquid scintillator system and was compared to the nominal range. Measurements were made on three different days to evaluate the setup robustness from day to day, and three sets of measurements were made for each day to evaluate the consistency from delivery to delivery. All proton beam ranges measured using the liquid scintillator system were within half a millimeter of the nominal range. The delivery-to-delivery standard deviation of the range measurement was 0.04 mm, and the day-to-day standard deviation was 0.10 mm. In addition to the accuracy and robustness demonstrated by these results when our geometric calibration system was used, the liquid scintillator system allowed the range of all 94 proton beams to be measured in just two deliveries, making the liquid scintillator detector a perfect tool for range measurement of spot scanning proton beams. PMID:27274863

  5. Searching for dark matter annihilation to monoenergetic neutrinos with liquid scintillation detectors

    SciTech Connect

    Kumar, J.; Sandick, P.

    2015-06-22

    We consider searches for dark matter annihilation to monoenergetic neutrinos in the core of the Sun. We find that liquid scintillation neutrino detectors have enhanced sensitivity to this class of dark matter models, due to the energy and angular resolution possible for electron neutrinos and antineutrinos that scatter via charged-current interactions. In particular we find that KamLAND, utilizing existing data, could provide better sensitivity to such models than any current direct detection experiment for m{sub X}≲15 Gev. KamLAND’s sensitivity is signal-limited, and future liquid scintillation or liquid argon detectors with similar energy and angular resolution, but with larger exposure, will provide significantly better sensitivity. These detectors may be particularly powerful probes of dark matter with mass O(10) GeV.

  6. Searching for dark matter annihilation to monoenergetic neutrinos with liquid scintillation detectors

    SciTech Connect

    Kumar, J.; Sandick, P. E-mail: sandick@physics.utah.edu

    2015-06-01

    We consider searches for dark matter annihilation to monoenergetic neutrinos in the core of the Sun. We find that liquid scintillation neutrino detectors have enhanced sensitivity to this class of dark matter models, due to the energy and angular resolution possible for electron neutrinos and antineutrinos that scatter via charged-current interactions. In particular we find that KamLAND, utilizing existing data, could provide better sensitivity to such models than any current direct detection experiment for m{sub X} ∼< 15 Gev. KamLAND's sensitivity is signal-limited, and future liquid scintillation or liquid argon detectors with similar energy and angular resolution, but with larger exposure, will provide significantly better sensitivity. These detectors may be particularly powerful probes of dark matter with mass O(10) GeV.

  7. Ultrasonic liquid-in-line detector for tubes

    SciTech Connect

    Piper, Thomas C.

    1991-01-01

    An apparatus and method for detecting the presence of liquid in pipes or tubes using ultrasonic techniques A first piezoelectric crystal is coupled to the outside of the pipe or tube at the location where liquid in the tube is to be detected. A second piezoelectric crystal is coupled to the outside of the pipe or tube at the same location along the tube but circumferentially displaced from the first crystal by an angle around the pipe or tube of less than 180.degree.. Liquid in the pipe or tube is detected by measuring the attenuation of an ultrasonic signal sent by the first piezoelectric crystal and received by the second piezoelectric crystal.

  8. The research program of the Liquid Scintillation Detector (LSD) in the Mont Blanc Laboratory

    NASA Technical Reports Server (NTRS)

    Dadykin, V. L.; Yakushev, V. F.; Korchagin, P. V.; Korchagin, V. B.; Malgin, A. S.; Ryassny, F. G.; Ryazhskaya, O. G.; Talochkin, V. P.; Zatsepin, G. T.; Badino, G.

    1985-01-01

    A massive (90 tons) liquid scintillation detector (LSD) has been running since October 1984 in the Mont Blanc Laboratory at a depth of 5,200 hg/sq cm of standard rock. The research program of the experiment covers a variety of topics in particle physics and astrophysics. The performance of the detector, the main fields of research are presented and the preliminary results are discussed.

  9. Neutron emission measurement at the HL-2A tokamak device with a liquid scintillation detector

    SciTech Connect

    Xie, Xufei; Chen, Zhongjing; Peng, Xingyu; Yuan, Xi; Zhang, Xing; Cui, Zhiqiang; Du, Tengfei; Hu, Zhimeng; Li, Tao; Fan, Tieshuan Chen, Jinxiang; Li, Xiangqing; Zhang, Guohui; Gorini, Giuseppe; Yuan, Guoliang; Yang, Jinwei; Yang, Qingwei

    2014-10-15

    Neutron emission measurement at the HL-2A tokamak device with a liquid scintillation detector is described. The detector was placed at a location with little structure material in the field of view, and equipped with a gain monitoring system which could provide the possibility to evaluate the gain variation as well as to correct for the detector response. Time trace of the neutron emissivity was obtained and it was consistent with the result of a standard {sup 235}U fission chamber. During the plasma discharge the neutron yield could vary by about four orders of magnitude and the fluctuation of the detector gain was up to about 6%. Pulse height spectrum of the liquid scintillation detector was constructed and corrected with the aid of the gain monitoring system, and the correction was found to be essential for the assessment of the neutron energy spectrum. This successful measurement offered experience and confidence for the application of liquid scintillation detectors in the upcoming neutron camera system.

  10. Discriminating cosmic muons and radioactivity using a liquid scintillation fiber detector

    NASA Astrophysics Data System (ADS)

    Zhang, Y. P.; Xu, J. L.; Lu, H. Q.; Zhang, P.; Zhang, C. C.; Yang, C. G.

    2017-03-01

    In the case of underground experiments for neutrino physics or rare event searches, the background caused by cosmic muons contributes significantly and therefore must be identified and rejected. We proposed and optimized a new detector using liquid scintillator with wavelenghth-shifting fibers which can be employed as a veto detector for cosmic muons background rejection. From the prototype study, it has been found that the detector has good performances and is capable of discriminating between muons induced signals and environmental radiation background. Its muons detection efficiency is greater than 98%, and on average, 58 photo-electrons (p.e.) are collected when a muon passes through the detector. To optimize the design and enhance the collection of light, the reflectivity of the coating materials has been studied in detail. A Monte Carlo simulation of the detector has been developed and compared to the performed measurements showing a good agreement between data and simulation results.

  11. Development and Characterization of 6Li-doped Liquid Scintillator Detectors for PROSPECT

    NASA Astrophysics Data System (ADS)

    Gaison, Jeremy; Prospect Collaboration

    2016-09-01

    PROSPECT, the Precision Reactor Oscillation and Spectrum experiment, is a phased reactor antineutrino experiment designed to search for eV-scale sterile neutrinos via short-baseline neutrino oscillations and to make a precision measurement of the 235U reactor antineutrino spectrum. A multi-ton, optically segmented detector will be deployed at Oak Ridge National Laboratory's (ORNL) High Flux Isotope Reactor (HFIR) to measure the reactor spectrum at baselines ranging from 7-12m. A two-segment detector prototype with 50 liters of active liquid scintillator target has been built to verify the detector design and to benchmark its performance. In this presentation, we will summarize the performance of this detector prototype and describe the optical and energy calibration of the segmented PROSPECT detectors.

  12. Characterization of liquid scintillation detector (BC-501A) and digital pulse shape discrimination (DPSD) system

    SciTech Connect

    Lombigit, L. Yussup, N. Ibrahim, Maslina Mohd; Rahman, Nur Aira Abd; Rawi, M. Z. M.

    2015-04-29

    A digital n/γ pulse shape discrimination (PSD) system is currently under development at Instrumentation and Automation Centre, Malaysian Nuclear Agency. This system aims at simultaneous detection of fast neutron and gamma ray in mixed radiations environment. This work reports the system characterization performed on the liquid scintillation detector (BC-501A) and digital pulse shape discrimination (DPSD) system. The characterization involves measurement of electron light output from the BC-501A detector and energy channels calibration of the pulse height spectra acquired with DPSD system using set of photon reference sources. The main goal of this experiment is to calibrate the ADC channel of our DPSD system, characterized the BC-501 detector and find the position of Compton edge which later could be used as threshold for the n/γ PSD experiment. The detector resolution however is worse as compared to other published data but it is expected as our detector has a smaller active volume.

  13. An optical rotatory detector for high-performance liquid chromatography using polarization modulation.

    PubMed

    Yamamoto, Atsushi; Kawai, Mio; Sakamoto, Mitsunori; Kodama, Shuji; Hayakawa, Kazuichi

    2008-03-01

    A sensitive and variable-wavelength optical rotatory (OR) detector for high-performance liquid chromatography is presented. This design is entirely different from that of conventional OR detectors consisting of a crossed polarizer pair. By placing a polarizing prism and a retardation plate into a commercial circular dichroism (CD) detector, the OR signal was obtained. The Mueller matrix approach was used to prove the principle of the OR signal appearance. Sugars and 4-androstene-3,17-dione were chosen as test compounds. The limit of detection was below 0.5 microg of injected sucrose at 260 nm, which was superior to that obtained with a conventional OR detector. For 4-androstene-3,17-dione, which is CD active, and shows a large anomalous OR dispersion curve, our detector gave a large OR signal with approximately half the intensity of the CD signal at 340 nm.

  14. Neutron detection by scintillation of noble-gas excimers

    NASA Astrophysics Data System (ADS)

    McComb, Jacob Collin

    scintillation yields from the 10B( n, alpha)7Li reaction are comparable to the yields of many liquid and solid neutron scintillators. Additionally, the observed slow triplet-state decay of neutron-capture-induced excimers may be used in a practical detector to discriminate neutron interactions from gamma-ray interactions. The results of these measurements and simulations will contribute to the development and optimization of a deployable neutron detector based on noble-gas excimer scintillation.

  15. XEMIS: A liquid xenon detector for medical imaging

    NASA Astrophysics Data System (ADS)

    Gallego Manzano, L.; Bassetto, S.; Beaupere, N.; Briend, P.; Carlier, T.; Cherel, M.; Cussonneau, J.-P.; Donnard, J.; Gorski, M.; Hamanishi, R.; Kraeber Bodéré, F.; Le Ray, P.; Lemaire, O.; Masbou, J.; Mihara, S.; Morteau, E.; Scotto Lavina, L.; Stutzmann, J.-S.; Tauchi, T.; Thers, D.

    2015-07-01

    A new medical imaging technique based on the precise 3D location of a radioactive source by the simultaneous detection of 3γ rays has been proposed by Subatech laboratory. To take advantage of this novel technique a detection device based on a liquid xenon Compton telescope and a specific (β+, γ) emitter radionuclide, 44Sc, are required. A first prototype of a liquid xenon time projection chamber called XEMIS1 has been successfully developed showing very promising results for the energy and spatial resolutions for the ionization signal in liquid xenon, thanks to an advanced cryogenics system, which has contributed to a high liquid xenon purity with a very good stability and an ultra-low noise front-end electronics (below 100 electrons) operating at liquid xenon temperature. The very positive results obtained with XEMIS1 have led to the development of a second prototype for small animal imaging, XEMIS2, which is now under development. To study the feasibility of the 3γ imaging technique and optimize the characteristics of the device, a complete Monte Carlo simulation has been also carried out. A preliminary study shows very positive results for the sensitivity, energy and spatial resolutions of XEMIS2.

  16. Gamma thermometer based reactor core liquid level detector

    DOEpatents

    Burns, Thomas J.

    1983-01-01

    A system is provided which employs a modified gamma thermometer for determining the liquid coolant level within a nuclear reactor core. The gamma thermometer which normally is employed to monitor local core heat generation rate (reactor power), is modified by thermocouple junctions and leads to obtain an unambiguous indication of the presence or absence of coolant liquid at the gamma thermometer location. A signal processor generates a signal based on the thermometer surface heat transfer coefficient by comparing the signals from the thermocouples at the thermometer location. The generated signal is a direct indication of loss of coolant due to the change in surface heat transfer when coolant liquid drops below the thermometer location. The loss of coolant indication is independent of reactor power at the thermometer location. Further, the same thermometer may still be used for the normal power monitoring function.

  17. Gamma thermometer based reactor core liquid level detector

    SciTech Connect

    Burns, T.J.

    1983-09-20

    A system is provided which employs a modified gamma thermometer for determining the liquid coolant level within a nuclear reactor core. The gamma thermometer which normally is employed to monitor local core heat generation rate (reactor power), is midified by thermocouple junctions and leads to obtain an unambiguous indication of the presence or absence of coolant liquid at the gamma thermometer location. A signal processor generates a signal based on the thermometer surface heat transfer coefficient by comparing the signals from the thermocouples at the thermometer location. The generated signal is a direct indication of loss of coolant due to the change in surface heat transfer when coolant liquid drops below the thermometer location. The loss of coolant indication is independent of reactor power at the thermometer location. Further, the same thermometer may still be used for the normal power monitoring function.

  18. Monitoring gross alpha and beta activity in liquids by using ZnS(Ag) scintillation detectors

    SciTech Connect

    Stevanato, L.; Cester, D.; Filippi, D.; Lunardon, M.; Mistura, G.; Moretto, S.; Viesti, G.; Badocco, D.; Pastore, P.; Romanini, F.

    2015-07-01

    In this work the possibility of monitoring gross alpha and beta activity in liquids using EJ-444 was investigated. Specific tests were carried out to determine the change of the detector properties in water tests. Possible protecting coating is also proposed and tested. Alpha/beta real-time monitoring in liquids is a goal of the EU project TAWARA{sub R}TM. (authors)

  19. Modeling filters for formation of mono-energetic neutron beams in the research reactor IRT MEPhI and optimization of radiation shielding for liquid-xenon detector

    SciTech Connect

    Ivakhin, S. V.; Tikhomirov, G. V.; Bolozdynya, A. I.; Efremenko, Y. V.; Akimov, D. Y.; Stekhanov, V. N.

    2012-07-01

    The paper considers formation of mono-energetic neutron beams at the entrance of experimental channels in research reactors for various applications. The problem includes the following steps: 1. Full-scale mathematical model of the research IRT MEPhI was developed for numerical evaluations of neutron spectra and neutron spatial distribution in the area of experimental channels. 2. Modeling of filters in the channel to shift neutron spectrum towards the required mono-energetic line was performed. 3. Some characteristics of neutron beams at the entrance of detector were evaluated. The filter materials were selected. The calculations were carried out with application of the computer code based on the high-precision Monte-Carlo code MCNP. As a result, mathematical model was created for the filter which is able to form mono-energetic (24 keV) neutron beam. The study was carried out within the frames of the research project on development of Russian emission detector with liquid noble gas to observe rare processes of neutrino scattering and particles of hypothetical dark matter in atomic nuclei. (authors)

  20. Design optimization of liquid scintillator cosmic-ray veto detector with BBQ shifter

    SciTech Connect

    Kruse, H.W.; Egdorf, S.S.; Simmons, D.F.

    1981-10-01

    Certain design characteristics of a liquid scintillator detector for charged cosmic particles, have been studied. These include evaluation of scintillator emission spectra, absorption in various thicknesses of BBQ shifter bars and effective transmission in long lengths of BBQ acrylic. For our BBQ sample, 12.5 mm thick with semicircular shape, the shifted light was transmitted with 2.0 m absorption length.

  1. Simulation results of liquid and plastic scintillator detectors for reactor antineutrino detection - A comparison

    NASA Astrophysics Data System (ADS)

    Kashyap, V. K. S.; Pant, L. M.; Mohanty, A. K.; Datar, V. M.

    2016-03-01

    A simulation study of two kinds of scintillation detectors has been done using GEANT4. We compare plastic scintillator and liquid scintillator based designs for detecting electron antineutrinos emitted from the core of reactors. The motivation for this study is to set up an experiment at the research reactor facility at BARC for very short baseline neutrino oscillation study and remote reactor monitoring.

  2. Wireless remote liquid level detector and indicator for well testing

    DOEpatents

    Fasching, George E.; Evans, Donald M.; Ernest, John H.

    1985-01-01

    An acoustic system is provided for measuring the fluid level in oil, gas or water wells under pressure conditions that does not require an electrical link to the surface for level detection. A battery powered sound transmitter is integrated with a liquid sensor in the form of a conductivity probe, enclosed in a sealed housing which is lowered into a well by means of a wire line reel assembly. The sound transmitter generates an intense identifiable acoustic emission when the sensor contacts liquid in the well. The acoustic emissions propagate up the well which functions as a waveguide and are detected by an acoustic transducer. The output signal from the transducer is filtered to provide noise rejection outside of the acoustic signal spectrum. The filtered signal is used to indicate to an operator the liquid level in the well has been reached and the depth is read from a footage counter coupled with the wire line reel assembly at the instant the sound signal is received.

  3. Exploring detection of nuclearites in a large liquid scintillator neutrino detector

    NASA Astrophysics Data System (ADS)

    Guo, Wan-Lei; Xia, Cheng-Jun; Lin, Tao; Wang, Zhi-Min

    2017-01-01

    We take the JUNO experiment as an example to explore nuclearites in the future large liquid scintillator detector. Comparing to the previous calculations, the visible energy of nuclearites across the liquid scintillator will be reestimated for the liquid scintillator based detector. Then the JUNO sensitivities to the nuclearite flux are presented. It is found that the JUNO projected sensitivities can be better than 7.7 ×10-17 cm-2 s-1 sr-1 for the nuclearite mass 1 015 GeV ≤M ≤1 024 GeV and initial velocity 10-4≤β0≤10-1 with a 20 year running. Note that the JUNO will give the most stringent limits for downgoing nuclearites with 1.6 ×1 013 GeV ≤M ≤4.0 ×1 015 GeV and a typical galactic velocity β0=10-3.

  4. Ultrasonic liquid-level detector for varying temperature and pressure environments

    DOEpatents

    Anderson, R.L.; Miller, G.N.

    1981-10-26

    An ultrasonic liquid level detector for use in varying temperature and pressure environments, such as a pressurized water nuclear reactor vessel, is provided. The detector employs ultrasonic extensional and torsional waves launched in a multiplexed alternating sequence into a common sensor. The sensor is a rectangular cross section stainless steel rod which extends into the liquid medium whose level is to be detected. The sensor temperature derived from the extensional wave velocity measurements is used to compensate for the temperature dependence of the torsional wave velocity measurements which are also level dependent. The torsional wave velocity measurements of a multiple reflection sensor then provide a measurement of liquid level over a range of several meters with a small uncertainty over a temperature range of 20 to 250/sup 0/C and pressures up to 15 MPa.

  5. Fabrication and response of high concentration SIMPLE superheated droplet detectors with different liquids

    NASA Astrophysics Data System (ADS)

    Felizardo, M.; Morlat, T.; Marques, J. G.; Ramos, A. R.; Girard, TA; Fernandes, A. C.; Kling, A.; Lázaro, I.; Martins, R. C.; Puibasset, J.

    2013-09-01

    The combined measurement of dark matter interactions with different superheated liquids has recently been suggested as a cross-correlation technique in identifying WIMP candidates. We describe the fabrication of high concentration superheated droplet detectors based on the light nuclei liquids C3F8, C4F8, C4F10 and CCl2F2, and investigation of their irradiation response with respect to C2ClF5. The results are discussed in terms of the basic physics of superheated liquid response to particle interactions, as well as the necessary detector qualifications for application in dark matter search investigations. The possibility of heavier nuclei SDDs is explored using the light nuclei results as a basis, with CF3I provided as an example.

  6. Colloidal nickel/gallium nanoalloys obtained from organometallic precursors in conventional organic solvents and in ionic liquids: noble-metal-free alkyne semihydrogenation catalysts

    NASA Astrophysics Data System (ADS)

    Schütte, Kai; Doddi, Adinarayana; Kroll, Clarissa; Meyer, Hajo; Wiktor, Christian; Gemel, Christian; van Tendeloo, Gustaaf; Fischer, Roland A.; Janiak, Christoph

    2014-04-01

    Efforts to replace noble-metal catalysts by low-cost alternatives are of constant interest. The organometallic, non-aqueous wet-chemical synthesis of various hitherto unknown nanocrystalline Ni/Ga intermetallic materials and the use of NiGa for the selective semihydrogenation of alkynes to alkenes are reported. Thermal co-hydrogenolysis of the all-hydrocarbon precursors [Ni(COD)2] (COD = 1,5-cyclooctadiene) and GaCp* (Cp* = pentamethylcyclopentadienyl) in high-boiling organic solvents mesitylene and n-decane in molar ratios of 1 : 1, 2 : 3 and 3 : 1 yields the nano-crystalline powder materials of the over-all compositions NiGa, Ni2Ga3 and Ni3Ga, respectively. Microwave induced co-pyrolysis of the same precursors without additional hydrogen in the ionic liquid [BMIm][BF4] (BMIm = 1-butyl-3-methyl-imidazolium) selectively yields the intermetallic phases NiGa and Ni3Ga from the respective 1 : 1 and 3 : 1 molar ratios of the precursors. The obtained materials are characterized by transmission electron microscopy (TEM), energy dispersive X-ray spectroscopy (EDX), IR, powder X-ray diffraction (PXRD) and atomic absorption spectroscopy (AAS). The single-source precursor [Ni(GaCp*)(PMe3)3] with a fixed Ni : Ga stoichiometry of 1 : 1 was employed as well. In comparison with the co-hydrogenolytic dual precursor source approach it turned out to be less practical due to inefficient nickel incorporation caused by the parasitic formation of stable [Ni(PMe3)4]. The use of ionic liquid [BMIm][BF4] as a non-conventional solvent to control the reaction and stabilize the nanoparticles proved to be particularly advantageous and stable colloids of the nanoalloys NiGa and Ni3Ga were obtained. A phase-selective Ni/Ga colloid synthesis in conventional solvents and in the presence of surfactants such as hexadecylamine (HDA) was not feasible due to the undesired reactivity of HDA with GaCp* leading to inefficient gallium incorporation. Recyclable NiGa nanoparticles selectively

  7. Measurement of photoelectron yield of the CDEX-10 liquid argon detector prototype

    NASA Astrophysics Data System (ADS)

    Chen, Qing-Hao; Yue, Qian; Cheng, Jian-Ping; Kang, Ke-Jun; Li, Yuan-Jing; Lin, Shin-Ted; Tang, Chang-Jian; Xing, Hao-Yang; Yu, Xun-Zhen; Zeng, Ming; Zhu, Jing-Jun

    2016-11-01

    The China Dark Matter Experiment (CDEX) is a low background experiment at China Jinping Underground Laboratory (CJPL) designed to directly detect dark matter with a high-purity germanium (HPGe) detector. In the second phase, CDEX-10, which has a 10 kg germanium array detector system, a liquid argon (LAr) anti-Compton active shielding and cooling system is proposed. To study the properties of the LAr detector, a prototype with an active volume of 7 liters of liquid argon was built and operated. The photoelectron yields, as a critically important parameter for the prototype detector, have been measured to be 0.051-0.079 p.e./keV for 662 keV γ rays at different positions. The good agreement between the experimental and simulation results has provided a reasonable understanding and determination of the important parameters such as the surviving fraction of the excimers, the absorption length for 128 nm photons in liquid argon, the reflectivity of Teflon and so on.

  8. Noble gas magnetic resonator

    DOEpatents

    Walker, Thad Gilbert; Lancor, Brian Robert; Wyllie, Robert

    2014-04-15

    Precise measurements of a precessional rate of noble gas in a magnetic field is obtained by constraining the time averaged direction of the spins of a stimulating alkali gas to lie in a plane transverse to the magnetic field. In this way, the magnetic field of the alkali gas does not provide a net contribution to the precessional rate of the noble gas.

  9. Neutron light output response and resolution functions in EJ-309 liquid scintillation detectors

    SciTech Connect

    Enqvist, Andreas; Lawrence, Christopher C.; Wieger, Brian M.; Pozzi, Sara A.; Massey, Thomas N.

    2013-03-26

    Here, the neutron light output response functions and detector resolution functions were measured at Ohio University's tandem Van de Graaff generator for three cylindrical EJ-309 liquid scintillator cells, having dimensions 12.7(circle divide)-by-12.7, 7.6-by-7.6, and 7.6-by-5.1 cm. A 7.44 MeV deuteron beam was used on an Al-27 target generating a continuous spectrum over the energy range from a few hundred keV to over 10 MeV. The light output response functions are determined using an exponential fit. Detector resolution functions are obtained for the 12.7-by-12.7 and 7.6-by-7.6 cm detectors. It is demonstrated that the dependence on detector size is important for the light output response functions, but not to the same extent for the resolution function, even when photomultiplier tubes, detector material, and other detector characteristics are carefully matched.

  10. Advanced far infrared blocked impurity band detectors based on germanium liquid phase epitaxy

    NASA Technical Reports Server (NTRS)

    Olsen, C. S.

    1998-01-01

    This research has shown that epilayers with residual impurity concentrations of 5 x 10(sup 13) cm(exp -3) can be grown by producing the purest Pb available in the world. These epilayers have extremely low minority acceptor concentrations, which is ideal for fabrication of IR absorbing layers. The Pb LPE growth of Ge also has the advantageous property of gettering Cu from the epilayer and the substrate. Epilayers have been grown with intentional Sb doping for IR absorption on lightly doped substrates. This research has proven that properly working Ge BIB detectors can be fabricated from the liquid phase as long as pure enough solvents are available. The detectors have responded at reach minimum wavenumbers. Optimization of the Sb doping concentration should further decrease the photoionization energy of these detectors. Ge BIB detectors have been fabricated that respond to 60 cm(exp -1) with low responsivity. Through reduction of the minority residual impurities, detector performance has reached responsivities of 1 A/W. These detectors have exhibited quantum efficiency and NEP values that rival conventional photoconductors and are expected to provide a much more sensitive tool for new scientific discoveries in a number of fields, including solid state studies, astronomy, and cosmology.

  11. Advanced far infrared blocked impurity band detectors based on germanium liquid phase epitaxy

    SciTech Connect

    Olsen, Christopher Sean

    1998-05-01

    This research has shown that epilayers with residual impurity concentrations of 5 x 1013 cm-3 can be grown by producing the purest Pb available in the world. These epilayers have extremely low minority acceptor concentrations, which is ideal for fabrication of IR absorbing layers. The Pb LPE growth of Ge also has the advantageous property of gettering Cu from the epilayer and the substrate. Epilayers have been grown with intentional Sb doping for IR absorption on lightly doped substrates. This research has proven that properly working Ge BIB detectors can be fabricated from the liquid phase as long as pure enough solvents are available. The detectors have responded at proper wavelengths when reversed biased even though the response did not quite reach minimum wavenumbers. Optimization of the Sb doping concentration should further decrease the photoionization energy of these detectors. Ge BIB detectors have been fabricated that respond to 60 cm-1 with low responsivity. Through reduction of the minority residual impurities, detector performance has reached responsivities of 1 A/W. These detectors have exhibited quantum efficiency and NEP values that rival conventional photoconductors and are expected to provide a much more sensitive tool for new scientific discoveries in a number of fields, including solid state studies, astronomy, and cosmology.

  12. Neutron light output response and resolution functions in EJ-309 liquid scintillation detectors

    DOE PAGES

    Enqvist, Andreas; Lawrence, Christopher C.; Wieger, Brian M.; ...

    2013-03-26

    Here, the neutron light output response functions and detector resolution functions were measured at Ohio University's tandem Van de Graaff generator for three cylindrical EJ-309 liquid scintillator cells, having dimensions 12.7(circle divide)-by-12.7, 7.6-by-7.6, and 7.6-by-5.1 cm. A 7.44 MeV deuteron beam was used on an Al-27 target generating a continuous spectrum over the energy range from a few hundred keV to over 10 MeV. The light output response functions are determined using an exponential fit. Detector resolution functions are obtained for the 12.7-by-12.7 and 7.6-by-7.6 cm detectors. It is demonstrated that the dependence on detector size is important for themore » light output response functions, but not to the same extent for the resolution function, even when photomultiplier tubes, detector material, and other detector characteristics are carefully matched.« less

  13. Detectors

    DOEpatents

    Orr, Christopher Henry; Luff, Craig Janson; Dockray, Thomas; Macarthur, Duncan Whittemore; Bounds, John Alan; Allander, Krag

    2002-01-01

    The apparatus and method provide techniques through which both alpha and beta emission determinations can be made simultaneously using a simple detector structure. The technique uses a beta detector covered in an electrically conducting material, the electrically conducting material discharging ions generated by alpha emissions, and as a consequence providing a measure of those alpha emissions. The technique also offers improved mountings for alpha detectors and other forms of detectors against vibration and the consequential effects vibration has on measurement accuracy.

  14. Noble metal reforming of naphtha

    SciTech Connect

    Bonacci, J.C.; Patterson, J.R.

    1981-09-29

    Conventional noble metal reforming to upgrade the octane number of petroleum naphtha is an endothermic reaction which is carried out in a series of reactors with intermediate furnace heating of the petroleum fraction being upgraded. This specification discloses a process and apparatus configuration to increase the octane number of the reformate at a minimum liquid yield loss by cooling the first reforming stage effluent and then contacting the cooled effluent with a zsm-5 type zeolite catalyst prior to the first intermediate furnace heating.

  15. Development of a Position Sensitive Liquid Scintillator Bar-type Detector

    NASA Astrophysics Data System (ADS)

    Atencio, Ariella; Cizewski, Jolie; Walter, David; Chipps, Kelly; Febbraro, Michael; Pain, Steven; Smith, Karl; Thornsberry, Cory

    2016-09-01

    The ability to detect neutrons is important for both nuclear reactions and beta decay. Liquid scintillators have the useful property of Pulse Shape Discrimination(PSD), which can be used to separate gamma-ray-induced events when the scintillators are used as neutron detectors. Because of their ability to apply PSD, these liquid scintillators will have many applications in neutron detection, such as a recent experiment conducted at the University of Notre Dame. The liquid scintillators use a xylene based liquid made in-house at Oak Ridge National Laboratory. Naphthalene in the liquid scintillator improves the light output properties of the scintillator. An optimized method for the purification of naphthalene will be discussed as well as the first implementation of an array of these detectors. This work is supported in part by the NSF and the U.S. DOE. Research sponsored by the Laboratory Directed Research and Development Program of Oak Ridge National Laboratory, managed by UT-Battelle, LLC, for the U.S. Department of Energy.

  16. Scintillation efficiency for low energy nuclear recoils in liquid xenon dark matter detectors

    NASA Astrophysics Data System (ADS)

    Mu, Wei; Xiong, Xiaonu; Ji, Xiangdong

    2015-02-01

    We perform a theoretical study of the scintillation efficiency of the low energy region crucial for liquid xenon dark matter detectors. We develop a computer program to simulate the cascading process of the recoiling xenon nucleus in liquid xenon and calculate the nuclear quenching effect due to atomic collisions. We use the electronic stopping power extrapolated from experimental data to the low energy region, and take into account the effects of electron escape from electron-ion pair recombination using the generalized Thomas-Imel model fitted to scintillation data. Our result agrees well with the experiments from neutron scattering and vanishes rapidly as the recoil energy drops below 3 keV.

  17. Characterization of large area photomultiplier ETL 9357FLB for liquid argon detector

    NASA Astrophysics Data System (ADS)

    Du, Ying-Shuai; Yue, Qian; Liu, Yi-Bao; Chen, Qing-Hao; Li, Jin; Cheng, Jian-Ping; Kang, Ke-Jun; Li, Yuan-Jing; Li, Yu-Lan; Ma, Hao; Xing, Hao-Yang; Yu, Xun-Zhen; Zeng, Zhi

    2014-07-01

    The China Dark Matter Experiment (CDEX) Collaboration will carry out a direct search for weakly interacting massive particles with germanium detectors. Liquid argon will be utilized as an anti-Compton and cooling material for the germanium detectors. A low-background and large-area photomultiplier tube (PMT) immersed in liquid argon will be used to read out the light signal from the argon. In this paper we have carried out a careful evaluation on the performance of the PMT operating at both room and cryogenic temperatures. Based on the single photoelectron response model, the absolute gain and resolution of the PMT were measured. This has laid a foundation for PMT selection, calibration and signal analysis in the forthcoming CDEX experiments.

  18. A Novel Cosmic Ray Tagger System for Liquid Argon TPC Neutrino Detectors

    SciTech Connect

    Auger, M.; Del Tutto, M.; Ereditato, A.; Fleming, B.; Goeldi, D.; Gramellini, E.; Guenette, R.; Ketchum, W.; Kreslo, I.; Laube, A.; Lorca, D.; Luethi, M.; Rudolf von Rohr, C.; Sinclair, J. R.; Soleti, S. R.; Weber, M.

    2016-12-14

    The Fermilab Short Baseline Neutrino (SBN) program aims to observe and reconstruct thousands of neutrino-argon interactions with its three detectors (SBND, MicroBooNE and ICARUS-T600), using their hundred of tonnes Liquid Argon Time Projection Chambers to perform a rich physics analysis program, in particular focused in the search for sterile neutrinos. Given the relatively shallow depth of the detectors, the continuos flux of cosmic ray particles which crossing their volumes introduces a constant background which can be falsely identified as part of the event of interest. Here we present the Cosmic Ray Tagger (CRT) system, a novel technique to tag and identify these crossing particles using scintillation modules which measure their time and coordinates relative to events internal to the neutrino detector, mitigating therefore their effect in the event tracking reconstruction.

  19. Dosimetric study of thermoluminescent detectors in clinical photon beams using liquid water and PMMA phantoms.

    PubMed

    Matsushima, Luciana C; Veneziani, Glauco R; Sakuraba, Roberto K; da Cruz, José C; Campos, Letícia L

    2012-07-01

    The purpose of this study was the dosimetric evaluation of thermoluminescent detectors of calcium sulphate doped with dysprosium (CaSO4:Dy) produced by IPEN compared to the TL response of lithium fluoride doped with magnesium and titanium (LiF:Mg,Ti) dosimeters and microdosimeters produced by Harshaw Chemical Company to clinical photon beams dosimetry (6 and 15 MV) using liquid water and PMMA phantoms.

  20. Near-infrared scintillation of liquid argon

    SciTech Connect

    Alexander, T.; Escobar, C. O.; Lippincott, W. H.; Rubinov, P.

    2016-03-03

    Since the 1970s it has been known that noble gases scintillate in the near infrared (NIR) region of the spectrum (0.7 $\\mu$m < $\\lambda$; < 1.5$\\mu$m). More controversial has been the question of the NIR light yield for condensed noble gases. We first present the motivation for using the NIR scintillation in liquid argon detectors, then briefly review early as well as more recent efforts and finally show encouraging preliminary results of a test performed at Fermilab.

  1. Low-energy recoils and energy scale in liquid xenon detector for direct dark matter searches

    NASA Astrophysics Data System (ADS)

    Wang, Lu; Mei, Dongming; Cubed Collaboration

    2015-04-01

    Liquid xenon has been proven to be a great detector medium for the direct search of dark matter. However, in the energy region of below 10 keV, the light yield and charge production are not fully understood due to the convolution of excitation, recombination and quenching. We have already studied a recombination model to explain the physics processes involved in liquid xenon. Work is continued on the average energy expended per electron-ion pair as a function of energy based on the cross sections for different type of scattering processes. In this paper, the results will be discussed in comparison with available experimental data using Birk's Law to understand how scintillation quenching contributes to the non-linear light yield for electron recoils with energy below 10 keV in liquid xenon. This work is supported by DOE Grant DE-FG02-10ER46709 and the state of South Dakota.

  2. SU-E-T-641: Proton Range Measurements Using a Geometrically Calibrated Liquid Scintillator Detector

    SciTech Connect

    Hui, C; Robertson, D; Alsanea, F; Beddar, S

    2015-06-15

    Purpose: The purpose of this work is to develop a geometric calibration method to accurately calculate physical distances within a liquid scintillator detector and to assess the accuracy, consistency, and robustness of proton beam range measurements when using a liquid scintillator detector system with the proposed geometric calibration process. Methods: We developed a geometric calibration procedure to accurately convert pixel locations in the camera frame into physical locations in the scintillator frame. To ensure accuracy, the geometric calibration was performed before each experiment. The liquid scintillator was irradiated with spot scanning proton beams of 94 energies in two deliveries. A CCD camera was used to capture the two-dimensional scintillation light profile of each of the proton energies. An algorithm was developed to automatically calculate the proton range from the acquired images. The measured range was compared to the nominal range to assess the accuracy of the detector. To evaluate the robustness of the detector between each setup, the experiments were repeated on three different days. To evaluate the consistency of the measurements between deliveries, three sets of measurements were acquired for each experiment. Results: Using this geometric calibration procedure, the proton beam ranges measured using the liquid scintillator system were all within 0.3mm of the nominal range. The average difference between the measured and nominal ranges was −0.20mm. The delivery-to-delivery standard deviation of the proton range measurement was 0.04mm, and the setup-to-setup standard deviation of the measurement was 0.10mm. Conclusion: The liquid scintillator system can measure the range of all 94 beams in just two deliveries. With the proposed geometric calibration, it can measure proton range with sub-millimeter accuracy, and the measurements were shown to be consistent between deliveries and setups. Therefore, we conclude that the liquid scintillator

  3. Prompt directional detection of galactic supernova by combining large liquid scintillator neutrino detectors

    SciTech Connect

    Fischer, V.; Chirac, T.; Lasserre, T. E-mail: tchirac@gmail.fr; and others

    2015-08-01

    Core-collapse supernovae produce an intense burst of electron antineutrinos in the few-tens-of-MeV range. Several Large Liquid Scintillator-based Detectors (LLSD) are currently operated worldwide, being very effective for low energy antineutrino detection through the Inverse Beta Decay (IBD) process. In this article, we develop a procedure for the prompt extraction of the supernova location by revisiting the details of IBD kinematics over the broad energy range of supernova neutrinos. Combining all current scintillator-based detector, we show that one can locate a canonical supernova at 10 kpc with an accuracy of 45 degrees (68% C.L.). After the addition of the next generation of scintillator-based detectors, the accuracy could reach 12 degrees (68% C.L.), therefore reaching the performances of the large water Čerenkov neutrino detectors. We also discuss a possible improvement of the SuperNova Early Warning System (SNEWS) inter-experiment network with the implementation of a directionality information in each experiment. Finally, we discuss the possibility to constrain the neutrino energy spectrum as well as the mass of the newly born neutron star with the LLSD data.

  4. Characterization of liquid phase epitaxial GaAs forblocked-impurity-band far-infrared detectors

    SciTech Connect

    Cardozo, B.L.; Reichertz, L.A.; Beeman, J.W.; Haller, E.E.

    2004-04-07

    GaAs Blocked-Impurity-Band (BIB) photoconductor detectors have the potential to become the most sensitive, low noise detectors in the far-infrared below 45.5 cm{sup -1} (220 {micro}m). We have studied the characteristics of liquid phase epitaxial GaAs films relevant to BIB production, including impurity band formation and the infrared absorption of the active section of the device. Knowledge of the far-infrared absorption spectrum as a function of donor concentration combined with variable temperature Hall effect and resistivity studies leads us to conclude that the optimal concentration for the absorbing layer of a GaAs BIB detector lies between 1 x 10{sup 15} and 6.7 x 10{sup 15} cm{sup -3}. At these concentrations there is significant wavefunction overlap which in turn leads to absorption beyond the 1s ground to 2p bound excited state transition of 35.5 cm{sup -1} (282 {micro}m). There still remains a gap between the upper edge of the donor band and the bottom of the conduction band, a necessity for proper BIB detector operation.

  5. Assembly and Commissioning of a Liquid Argon Detector and Development of a Slow Control System for the COHERENT Experiment

    NASA Astrophysics Data System (ADS)

    Kaemingk, Michael; Cooper, Robert; Coherent Collaboration

    2016-09-01

    COHERENT is a collaboration whose goal is to measure coherent elastic neutrino-nucleus scattering (CEvNS). COHERENT plans to deploy a suite of detectors to measure the expected number-of-neutrons squared dependence of CEvNS at the Spallation Neutron Source at Oak Ridge National Laboratory. One of these detectors is a liquid argon detector which can measure these low energy nuclear recoil interactions. Ensuring optimal functionality requires the development of a slow control system to monitor and control various aspects, such as the temperature and pressure, of these detectors. Electronics manufactured by Beckhoff, Digilent, and Arduino among others are being used to create these slow control systems. This poster will generally discuss the assembly and commissioning of this CENNS-10 liquid argon detector at Indiana University and will feature work on the slow control systems.

  6. New Measurement of ^39Ar in Underground Argon with a Low Background Liquid Argon Detector

    NASA Astrophysics Data System (ADS)

    Xu, Jingke

    2012-03-01

    A low background liquid argon detector has been developed for sensitive measurements of the beta radioactive ^39Ar in argon from underground sources. The measurement is motivated by the need to improve on earlier studies that showed no sign of ^39Ar in certain sources of underground argon, but with a limited sensitivity of ˜ 5% relative to ^39Ar in atmospheric argon[1]. We will report preliminary measurements taken with the low background detector that was commissioned and operated at the Kimballton Underground Research Facility (KURF) in Virginia. A combination of passive and active background reduction techniques resulted in a very low background and a null result with sensitivity to ^39Ar less than 1% of atmospheric. The results confirm that underground argon is well suited for direct detection of dark matter WIMPs. [4pt] [1] D. Acosta-Kane et al., Nucl. Instr. Meth. A 587:46 (2008)

  7. GLADE Global Liquid Argon Detector Experiment: a letter of intent to FNAL

    SciTech Connect

    Thomas, Jennifer

    2012-05-13

    The recent measurements of the {theta}{sub 13} mixing angle, which controls the observable size of any CP violation effects, open a window of opportunity to take advantage of the world's most powerful existing neutrino beam together with recent successes in development of the ultimate detector technology for the detection of electron neutrinos : a liquid argon (LAr) time projection chamber. During this proposed project a 5kt LAr detector (GLADE) will be developed by European groups to be put in a cryostat in the NuMI neutrino beam at Fermi National Accelerator Laboratory in the US and will start taking data in 3-5 years time to address the neutrino mass ordering. The successful fruition of this project, along with nominal exposure at NO{nu}A and T2K, together with information from double beta decay experiments could ascertain that neutrinos are Dirac particles in the next decade.

  8. Unfolding the fast neutron spectra of a BC501A liquid scintillation detector using GRAVEL method

    NASA Astrophysics Data System (ADS)

    Chen, YongHao; Chen, XiMeng; Lei, JiaRong; An, Li; Zhang, XiaoDong; Shao, JianXiong; Zheng, Pu; Wang, XinHua

    2014-10-01

    Accurate knowledge of the neutron energy spectra is useful in basic research and applications. The overall procedure of measuring and unfolding the fast neutron energy spectra with BC501A liquid scintillation detector is described. The recoil proton spectrum of 241Am-Be neutrons was obtained experimentally. With the NRESP7 code, the response matrix of detector was simulated. Combining the recoil proton spectrum and response matrix, the unfolding of neutron spectra was performed by GRAVEL iterative algorithm. A MatLab program based on the GRAVEL method was developed. The continuous neutron spectrum of 241Am-Be source and monoenergetic neutron spectrum of D-T source have been unfolded successfully and are in good agreement with their standard reference spectra. The unfolded 241Am-Be spectrum are more accurate than the spectra unfolded by artificial neural networks in recent years.

  9. Improving the time response of a gamma/neutron liquid detector

    NASA Astrophysics Data System (ADS)

    Malone, Robert M.; Buckles, Robert A.; DeYoung, Anemarie; Garza, Irene; Frayer, Daniel K.; Kaufman, Morris I.; Morgan, George L.; Obst, Andrew W.; Rundberg, Robert S.; Tinsley, Jim; Waltman, Tom B.; Yuan, Vincent W.

    2016-09-01

    A pulsed neutron source is used to interrogate a target, producing secondary gammas and neutrons. In order to make good use of the relatively small number of gamma rays that emerge from the system after the neutron flash, our detector system must be both efficient in converting gamma rays to a detectable electronic signal and reasonably large in volume. Isotropic gamma rays are emitted from the target. These signals are converted to light within a large chamber of a liquid scintillator. To provide adequate time-of-flight separation between the gamma and neutron signals, the liquid scintillator is placed meters away from the target under interrogation. An acrylic PMMA (polymethyl methacrylate) light guide directs the emission light from the chamber into a 5-inch-diameter photomultiplier tube. However, this PMMA light guide produces a time delay for much of the light. Illumination design programs count rays traced from the source to a receiver. By including the index of refraction of the different materials that the rays pass through, the optical power at the receiver is calculated. An illumination design program can be used to optimize the optical material geometries to maximize the ray count and/or the receiver power. A macro was written to collect the optical path lengths of the rays and import them into a spreadsheet, where histograms of the time histories of the rays are plotted. This method allows optimization on the time response of different optical detector systems. One liquid scintillator chamber has been filled with a grid of reflective plates to improve its time response. Cylindrical detector geometries are more efficient.

  10. Apparatus complex based on liquid xenon detector for gamma spectrometry in the intervals between pulses of intense radiation

    NASA Astrophysics Data System (ADS)

    Kirsanov, M. A.

    2017-01-01

    To investigate the effects of intense radiation on the operation of the liquid xenon spectrometer we have created apparatus complex on the basis of the liquid xenon detector. The experimental setup consists of a multifunctional chamber, gas system, cooling system, temperature control system, X-ray generator, a special preamp, passive protection, scintillation monitor of the accelerator beam, thermoluminescent dosimeters, copper monitor bremsstrahlung, Ge(Li) detector. Multifunctional chamber includes a detecting unit (flat or cylindrical ionization chamber), the cleaning unit of the xenon, control unit of the purity of liquid xenon. The liquid xenon detector was irradiated by bremsstrahlung pulses of the microtron. The frequency of irradiation pulses was 400 Hz. The absorbed dose was varied from 10-7 to 0.1 Gy per pulse. The electronic and ionic processes in liquid xenon at different radiation doses were investigated. The recovery time of the spectrometric mode of operation of the liquid xenon detector after intense pulse irradiation has been studied. Stable operation of the liquid xenon spectrometer in the intervals between the pulses of the accelerator shown for a long time.

  11. Consent Decree for Noble Energy

    EPA Pesticide Factsheets

    Noble Energy, Inc. (Noble) that comprehensively identifies and addresses issues with vapor control systems at Noble’s condensate storage tank batteries in the Denver-area 8-hour ozone marginal nonattainment area (nonattainment area).

  12. Development of a gadolinium-loaded liquid scintillator for the Hanaro short baseline prototype detector

    NASA Astrophysics Data System (ADS)

    Yeo, In Sung; Joo, Kyung Kwang; So, Sun Heang; Song, Sook Hyung; Kim, Hong Joo; So, Jung Ho; Park, Kang Soon; Ma, Kyung Ju; Jeon, Eun Ju; Kim, Jin Yu; Kim, Young Duk; Lee, Jason; Lee, Jeong-Yeon; Sun, Gwang-Min

    2014-02-01

    We propose a new experiment on the site of the Korea Atomic Energy Research Institute (KAERI) located at Daejeon, Korea. The Hanaro short baseline (SBL) nuclear reactor with a thermal power output 30 MW is used to investigate a reactor neutrino anomaly. A Hanaro SBL prototype detector having a 60- l volume has been constructed ˜6 m away from the reactor core. A gadolinium (Gd)-loaded liquid scintillator (LS) is used as an active material to trigger events. The selection of the LS is guided by physical and technical requirements, as well as safety considerations. A linear alkyl benzene (LAB) is used as a base solvent of the Hanaro SBL prototype detector. Three g/ l of PPO and 30 mg/ l of bis-MSB are dissolved to formulate the LAB-based LS. Then, a 0.5% gadolinium (Gd) complex with carboxylic acid is loaded into the LAB-based LS by using the liquidliquid extraction method. In this paper, we will summarize all the characteristics of the Gd-loaded LAB-based LS for the Hanaro prototype detector.

  13. Limits on low-energy neutrino fluxes with the Mont Blanc liquid scintillator detector

    NASA Astrophysics Data System (ADS)

    Aglietta, M.; Antonioli, P.; Badino, G.; Bologna, G.; Castagnoli, C.; Castellina, A.; Dadykin, V. L.; Fulgione, W.; Galeotti, P.; Khalchukov, F. F.; Korolkova, E. V.; Kortchaguin, P. V.; Kortchaguin, V. B.; Kudryavtsev, V. A.; Malguin, A. S.; Periale, L.; Ryassny, V. G.; Ryazhskaya, O. G.; Saavedra, O.; Trinchero, G.; Vernetto, S.; Yakushev, V. F.; Zatsepin, G. T.

    1992-11-01

    The LSD liquid scintillation detector has been operating since 1985 as an underground neutrino observatory in the Mont Blanc Laboratory with the main objective of detecting antineutrino bursts from collapsing stars. In August 1988 the construction of an additional lead and borex paraffin shield considerably reduced the radioactive background and increased the sensitivity of the apparatus. In this way the search for steady fluxes of low-energy neutrinos of different flavours through their interactions with free protons and carbon nuclei of the scintillator was made possible. No evidence for a galactic collapse was observed during the whole period of measurement. The corresponding 90% c.l. upper limit on the galactic collapses rate is 0.45 y -1 for a burst duration of ΔT ⩽ 10 s. After analysing the last 3 years data, the following 90% c.l. upper limits on the steady neutrino and antineutrino fluxes were obtained:

  14. Results of the liquid scintillation detector of the Mont Blanc Laboratory

    NASA Astrophysics Data System (ADS)

    Aglietta, M.; Badino, G.; Bologna, G. F.; Castagnoli, C.; Fulgione, W.

    1986-04-01

    Preliminary results research on collapsing-star neutrino bursts and cosmic-ray muons, obtained using the 90-ton 72 element liquid-scintillation detector (LSD) at Mt. Blanc Laboratory since October 1984, are presented in tables and graphs and characterized. The theoretically expected energy and time values for neutrinos from collapsing stars of 2 solar mass are calculated, and it is shown that no burst with multiplicity 6 or greater and Delta t 30 s or less was detected in 4 mo of LSD live time, corresponding to a preliminary upper limit of 3/yr for Galactic stellar collapses. About 3 muons/h crossing at least two counters were observed, and detection of aobut 700 muon bundles per year of multiplicity 2 or greater or 90 bundles per year of multiplicity 3 or greater is predicted. The possible use of the LSD to search for nucleon instability (proton decay into muons) is considered.

  15. Thermal lens-circular dichroism detector for high-performance liquid chromatography.

    PubMed

    Xu, M R; Tran, C D

    1990-11-15

    A novel and ultrasensitive chiral detector for high-performance liquid chromatography has been developed. This detector is based on the measurement of circular dichroism of chiral effluents by the thermal lens effect. In this instrument, the chromatographic effluent was sequentially excited by left circularly polarized laser light (LCPL) and right circularly polarized laser light (RCPL); both of these excitation beams were derived from the same argon ion laser whose linearly polarized output was transformed into circularly polarized light by means of a Pockels cell. The heat generated as a consequence of the sample absorption of the LCPL and RCPL was measured by the probe laser beam collinearly overlapping with the two excitation beams. A lock-in amplifier was used to measure the thermal lens-circular dichroism (TL-CD) signal which corresponds to the difference in the thermal lens signals produced by the LCPL and RCPL excitation beams. In addition to its high sensitivity, the advantages of this TL-CD chiral detector include its ability to provide, directly and in real time, information on the chirality (i.e., circular dichroism) and optical purity of chiral samples. A detection limit of 7.2 ng was achieved for (-)-tris(ethylenediamine)cobalt(III) (k' = 0.45) as well as for the (+)-tris(ethylenediamine)cobalt(III) (k' = 1.40) when these two enantiomers were chromatographically separated from the corresponding racemic mixture through the use of bis(mu-d-tartrato)diantiomonate(III) ion pair reversed-phase chromatography. This limit of detection was found by using a 10-microL flow cell and having 5-mm path length and 6-mW excitation laser beam (lambda = 514.5 nm) modulated at 2 Hz.

  16. Cosmogenic noble gas paleothermometry

    NASA Astrophysics Data System (ADS)

    Tremblay, Marissa M.; Shuster, David L.; Balco, Greg

    2014-08-01

    We present a theoretical basis for reconstructing paleotemperatures from the open-system behavior of cosmogenic noble gases produced in minerals at Earth's surface. Experimentally-determined diffusion kinetics predicts diffusive loss of cosmogenic 3He and 21Ne from common minerals like quartz and feldspars at ambient temperatures; incomplete retention has also been observed empirically in field studies. We show that the theory of simultaneous production and diffusion that applies to radiogenic noble gases in minerals-the basis of thermochronology-can also be applied to cosmogenic noble gases to reconstruct past surface temperatures on Earth. We use published diffusion kinetics and production rates for 3He in quartz and 21Ne in orthoclase to demonstrate the resolving power of cosmogenic noble gas paleothermometry with respect to exposure duration, temperature, and diffusion domain size. Calculations indicate that, when paired with a quantitatively retained cosmogenic nuclide such as 21Ne or 10Be, observations of cosmogenic 3He in quartz can constrain temperatures during surface exposure in polar and high altitude environments. Likewise, 21Ne retention in feldspars is sensitive to temperatures at lower latitudes and elevations, expanding the potential geographic applicability of this technique to most latitudes. As an example, we present paired measurements of 3He and 10Be in quartz from a suite of Antarctic sandstone erratics to test whether the abundances of cosmogenic 3He agree with what is predicted from first principles and laboratory-determined diffusion kinetics. We find that the amounts of cosmogenic 3He present in these samples are consistent with the known mean annual temperature (MAT) for this region of Antarctica between -25 and -30 °C. These results demonstrate the method's ability to record paleotemperatures through geologic time.

  17. Construction of a wireless communication contact closure system for liquid chromatography with multiple parallel mass spectrometers and other detectors.

    PubMed

    Byrdwell, William Craig

    2014-10-01

    A contact closure system was constructed that uses two contact closure sender boards that communicate wirelessly to four contact closure receiver boards to distribute start signals from two or three liquid chromatographs to 14 instruments, pumps, detectors, or other components. Default high, closed low, TTL logic (5-volt) start signals from two autosamplers are converted to simple contacts by powered relay boards that are then connected to two 16-channel wireless contact closure sender boards. The contact closure signals from the two sender boards are transmitted wirelessly to two pairs of eight-channel receiver boards (total of 32 contact signals) that distribute the start signal to 14 switches that allow selection of which start signal is sent to which instrument, pump, or detector. The contact closure system is used for quadruple parallel mass spectrometry experiments in which four mass spectrometers, using three different atmospheric pressure ionization modes, plus a UV detector, an evaporative light-scattering detector, a corona charged aerosol detector, and two syringe pumps supplying electrolyte, are all synchronized to start simultaneously. A wide variety of liquid chromatography-mass spectrometry experiments using multiple liquid chromatographs and mass spectrometers simultaneously, LCx/MSy, including column-switching experiments, can be reconfigured simply by toggling switches.

  18. Construction of a wireless communication contact closure system for liquid chromatography with multiple parallel mass spectrometers and other detectors

    Technology Transfer Automated Retrieval System (TEKTRAN)

    A contact closure system has been constructed and implemented that utilizes two contact closure sender boards that communicate wirelessly to four contact closure receiver boards to distribute start signals from two or three liquid chromatographs to fourteen instruments, pumps, detectors, or other co...

  19. Tomographic analysis of neutron and gamma pulse shape distributions from liquid scintillation detectors at Joint European Torus

    SciTech Connect

    Giacomelli, L.; Conroy, S.; Gorini, G.; Horton, L.; Murari, A.; Popovichev, S.; Syme, D. B.

    2014-02-15

    The Joint European Torus (JET, Culham, UK) is the largest tokamak in the world devoted to nuclear fusion experiments of magnetic confined Deuterium (D)/Deuterium-Tritium (DT) plasmas. Neutrons produced in these plasmas are measured using various types of neutron detectors and spectrometers. Two of these instruments on JET make use of organic liquid scintillator detectors. The neutron emission profile monitor implements 19 liquid scintillation counters to detect the 2.45 MeV neutron emission from D plasmas. A new compact neutron spectrometer is operational at JET since 2010 to measure the neutron energy spectra from both D and DT plasmas. Liquid scintillation detectors are sensitive to both neutron and gamma radiation but give light responses of different decay time such that pulse shape discrimination techniques can be applied to identify the neutron contribution of interest from the data. The most common technique consists of integrating the radiation pulse shapes within different ranges of their rising and/or trailing edges. In this article, a step forward in this type of analysis is presented. The method applies a tomographic analysis of the 3-dimensional neutron and gamma pulse shape and pulse height distribution data obtained from liquid scintillation detectors such that n/γ discrimination can be improved to lower energies and additional information can be gained on neutron contributions to the gamma events and vice versa.

  20. Genesis Noble Gas Measurements

    NASA Technical Reports Server (NTRS)

    Hohenberg, Charles M.

    2005-01-01

    The original thrust of our Genesis funding was to extend and refine the noble gas analytical capabilities of this laboratory to improve the precision and accuracy of noble gas measurements in order to optimize the scientific return from the Genesis Mission. This process involved both instrumental improvement (supplemented by a SRLIDAP instrument grant) and refinement of technique. The Genesis landing mishap shifted our emphasis to the irregular aluminum heat shield material from the flat collector wafers. This has required redesign of our laser extraction cells to accommodate the longer focal lengths required for laser extraction from non-flat surfaces. Extraction of noble gases from solid aluminum surfaces, rather than thin coatings on transparent substrates has required refinement of controlled-depth laser ablation techniques. Both of these bring new problems, both with potentially higher blanks form larger laser cells and the larger quantities of evaporated aluminum which can coat the sapphire entrance ports. This is mainly a problem for the heavy noble gases where larger extraction areas are required, necessitating the new aluminum vapor containment techniques described below. With the Genesis Mission came three new multiple multiplier noble gas mass spectrometers to this laboratory, one built solely by us (Supergnome-M), one built in collaboration with Nu-Instruments (Noblesse), and one built in collaboration with GVI (Helix). All of these have multiple multiplier detection sections with the Nu-Instruments using a pair of electrostatic quad lenses for isotope spacing and the other two using mechanically adjustable positions for the electron multipliers. The Supergnome-M and Noblesse are installed and running. The GVI instrument was delivered a year late (in March 2005) and is yet to be installed by GVI. As with all new instruments there were some initial development issues, some of which are still outstanding. The most serious of these are performance issues

  1. Quantification aspects of constant pressure (ultra) high pressure liquid chromatography using mass-sensitive detectors with a nebulizing interface.

    PubMed

    Verstraeten, M; Broeckhoven, K; Lynen, F; Choikhet, K; Landt, K; Dittmann, M; Witt, K; Sandra, P; Desmet, G

    2013-01-25

    The present contribution investigates the quantitation aspects of mass-sensitive detectors with nebulizing interface (ESI-MSD, ELSD, CAD) in the constant pressure gradient elution mode. In this operation mode, the pressure is controlled and maintained at a set value and the liquid flow rate will vary according to the inverse mobile phase viscosity. As the pressure is continuously kept at the allowable maximum during the entire gradient run, the average liquid flow rate is higher compared to that in the conventional constant flow rate operation mode, thus shortening the analysis time. The following three mass-sensitive detectors were investigated: mass spectrometry detector (MS), evaporative light scattering detector (ELSD) and charged aerosol detector (CAD) and a wide variety of samples (phenones, polyaromatic hydrocarbons, wine, cocoa butter) has been considered. It was found that the nebulizing efficiency of the LC-interfaces of the three detectors under consideration changes with the increasing liquid flow rate. For the MS, the increasing flow rate leads to a lower peak area whereas for the ELSD the peak area increases compared to the constant flow rate mode. The peak area obtained with a CAD is rather insensitive to the liquid flow rate. The reproducibility of the peak area remains similar in both modes, although variation in system permeability compromises the 'long-term' reproducibility. This problem can however be overcome by running a flow rate program with an optimized flow rate and composition profile obtained from the constant pressure mode. In this case, the quantification remains reproducibile, despite any occuring variations of the system permeability. Furthermore, the same fragmentation pattern (MS) has been found in the constant pressure mode compared to the customary constant flow rate mode.

  2. Absolute measurement of anti. nu. /sub p/ for /sup 252/Cf using the ORNL large liquid scintillator neutron detector

    SciTech Connect

    Spencer, R.R.; Gwin, R.; Ingle, R.

    1981-08-01

    The ORNL large liquid scintillator detector was used in a precise determination of anti ..nu../sub p/, the number of neutrons emitted promptly, for spontaneous fission of /sup 252/Cf. Measurements of the detector efficiency over a broad energy region were made by means of a proton-recoil technique employing the ORELA white neutron source. Monte Carlo calculation of the detector efficiency for a spectrum representative of /sup 252/Cf fission neutrons was calibrated with these elaborate measurements. The unusually flat response of the neutron detector resulted in elimination of several known sources of error. Experimental measurement was coupled with calculational methods to correct for other known errors. These measurements lead to an unusually small estimated uncertainty of 0.2% in the value obtained, anti ..nu../sub p/ = 3.773 +- 0.007.

  3. MicroBooNE and the Road to Large Liquid Argon Neutrino Detectors

    NASA Astrophysics Data System (ADS)

    Karagiorgi, G.

    Liquid Argon Time Projection Chambers (LArTPC's) provide a promising technology for multi-kiloton scale detectors aiming to address-among other pressing particle physics questions-the possibility of short and long baseline electron neutrino and antineutrino appearance. MicroBooNE, a 170 ton LArTPC under construction, is the next necessary step in a phased R&D effort toward construction and stable operation of larger-scale LArTPC's. This development effort also leans heavily on the ArgoNeuT and LAr1 LArTPC R&D experiments at Fermilab. In addition to advancing the LArTPC technology, these projects also provide unique physics opportunities. For example, Micro-BooNE will be located in the Booster Neutrino Beamline at Fermilab, at ∼470 m from neutrino production. Thus, in addition to measuring a suite of low energy neutrino cross sections on argon, MicroBooNE will investigate the anomalous low energy excess seen by the MiniBooNE experiment. Furthermore, the neutrino beam energy and relatively short baseline provide MicroBooNE with sensitivity to high-∼m2 neutrino oscillations. These proceedings summarize the role of the MicroBooNE detector in the US LArTPC R&D program, present its physics reach, and briefly discuss the physics potential of a dedicated near-future neutrino oscillation program at the Booster Neutrino Beamline, as a way to maximize the physics output of the Fermilab LArTPC R&D projects.

  4. Sensor and Instrumentation Development for Cryogenic Detectors

    NASA Astrophysics Data System (ADS)

    Allen, Nicholas; Febbraro, Micheal; Pain, Steven; Aidala, Christine; Lesser, Ezra; White, Aaron

    2015-10-01

    In the study of nuclear science, there is an ever increasing need for better efficiency and resolution in In nuclear sciences, new detectors with improved detection efficiency and energy resolution are constantly needed to drive experimental discovery and accuracy. Certain cryogenic liquids, particularly liquid noble gases such as Argon and Xenon, are very sensitive to energy deposited by ionizing particles and have many other useful properties for detector development. Developing these cryogenic liquids to operate with known detection methods offers exciting opportunities for experimental setups and has a wide variety of uses with regards to nuclear studies, such as gamma ray, neutron, and neutrino detection. However, operating at such low temperatures presents many complications when trying to effectively control and maintain detectors. In this poster, I will present some of the equipment and systems developed for particular low temperature applications. This will include the use of platinum resistance thermometers, capacitance-based liquid level sensors, and various systems used to regulate fluid flow for cryogenic detector systems.

  5. Development of an x-ray detector based on polymer- dispersed liquid crystal

    NASA Astrophysics Data System (ADS)

    Oh, K.; Hong, J.; Kim, G.; Park, S.; Min, B.; Yang, J.; Nam, S.

    2015-02-01

    The applications of active matrix flat-panel imagers (AMFPIs) in large-area x-ray imaging systems have increased over time but are still severely limited owing to its pixel resolution, complex fabrication processes, and high cost. As a solution, x-ray light valve (XLV) technology was introduced and expected to have a better resolution and contrast ratio than those of AMFPI, owing to its micrometer level of the LC cells and signal amplification by an external light source. The twisting angle of the LC cells was changed by charge carrier signals created in a photoconductor layer against x-rays, and the diagnostic images from XLV were acquired from the transmittance of the external light source. However, there was a possibility that the photoconductor layer may be crystallized or degenerated due to the application of high temperatures for sealing the LC layer during the fabrication process. To solve such problems, polymer-dispersed liquid crystals (PDLCs), which do not need high temperature for the sealing process of the LC layer, are used in this study instead of typical LC cells. A photoconductor and PDLC are combined to develop an x-ray detector. An external light source and optical sensor are used to investigate the light transmission of the PDLC . The PDLCs used in this paper do not need polarizers and are self-adhesive. Hence, the transmittance is very high in the transparent state, which allows for a linear x-ray response and sufficient dynamic range in digital radiography.

  6. Measuring the Low Energy Nuclear Quenching Factor in Liquid Argon for a Coherent Neutrino Scatter Detector

    NASA Astrophysics Data System (ADS)

    Foxe, M.; Bernstein, A.; Hagmann, C.; Joshi, T.; Jovanovic, I.; Kazkaz, K.; Sangiorgio, S.

    2012-08-01

    Coherent neutrino-nucleus scattering (CNS) is an as-yet undetected, flavor-independent neutrino interaction predicted by the Standard Model [D. Freedman, Phys. Rev. D 9 (5) (1974) 1389-1392]. One of the primary reasons the CNS interaction has yet to be observed is the very low energy depositions (less than 1 keV for MeV-energy neutrinos) [A. Drukier, L. Stodolsky, Phys. Rev. D 30 (11) (1984) 2295-2309]. An additional challenge in detecting CNS is nuclear quenching, which is a phenomenon encountered in many detection materials in which nuclear recoils produce less observable energy per unit energy deposited than electronic recoils. The ratio observed signal for nuclear recoils to electronic recoils or nuclear ionization quench factor, is presently unknown in argon at typical CNS energies [C. Hagmann, A. Bernstein, IEEE Trans. on Nucl. Sci. 51 (5) (2004) 2151-2155]. Here we present plans for using the Gamma or Neutron Argon Recoils Resulting in Liquid Ionization (G/NARRLI) detector to measure the nuclear ionization quench factor at ˜8 keV.

  7. Refractive index and absorption detector for liquid chromatography based on Fabry-Perot interferometry

    DOEpatents

    Yeung, E.S.; Woodruff, S.D.

    1984-06-19

    A refractive index and absorption detector are disclosed for liquid chromatography. It is based in part on a Fabry-Perot interferometer and is used for the improved detection of refractive index and absorption. It includes a Fabry-Perot interferometer having a normally fixed first partially reflecting mirror and a movable second partially reflecting mirror. A chromatographic flow-cell is positioned between the mirrors along the optical axis of a monochromatic laser beam passing through the interferometer. A means for deriving information about the interference fringes coming out of the interferometer is used with a mini-computer to compute the refractive index of the specimen injected into the flow cell. The minicomputer continuously scans the interferometer for continuous refractive index readings and outputs the continuous results of the scans on a chart recorder. The absorption of the specimen can concurrently be scanned by including a second optical path for an excitation laser which will not interfere with the first laser, but will affect the specimen so that absorption properties can be detected. By first scanning for the refractive index of the specimen, and then immediately adding the excitation laser and subsequently scanning for the refractive index again, the absorption of the specimen can be computed and recorded. 10 figs.

  8. Refractive index and absorption detector for liquid chromatography based on Fabry-Perot interferometry

    DOEpatents

    Yeung, Edward S.; Woodruff, Steven D.

    1984-06-19

    A refractive index and absorption detector for liquid chromatography. It is based in part on a Fabry-Perot interferometer and is used for the improved detection of refractive index and absorption. It includes a Fabry-Perot interferometer having a normally fixed first partially reflecting mirror and a movable second partially reflecting mirror. A chromatographic flow-cell is positioned between the mirrors along the optical axis of a monochromatic laser beam passing through the interferometer. A means for deriving information about the interference fringes coming out of the interferometer is used with a mini-computer to compute the refractive index of the specimen injected into the flow cell. The minicomputer continuously scans the interferometer for continuous refractive index readings and outputs the continuous results of the scans on a chart recorder. The absorption of the specimen can concurrently be scanned by including a second optical path for an excitation laser which will not interfere with the first laser, but will affect the specimen so that absorption properties can be detected. By first scanning for the refractive index of the specimen, and then immediately adding the excitation laser and subsequently scanning for the refractive index again, the absorption of the specimen can be computed and recorded.

  9. Observation of the dynamic behavior of liquid crystals using T-FDP (Transmission type four detectors polarimeter)

    NASA Astrophysics Data System (ADS)

    Kawabata, Shuichi; Arizi, Junichi; Shibuya, Takehisa; Wakaki, Moriaki

    2003-11-01

    We have constructed the four detectors polarimeter of transmission type (T-FDP) whose principle was originally invented by Azzam et. al. Some of the distinct features of our instrument are the liner optical axis and high speed data acquisition of msec order. It can determine the polarization state of the light that passed through the anisotropic materials such as liquid crystals in a very short time. We observed the dynamic change of the polarization state of the transmitted light through the liquid crystals (smectic and super twisted nematic) that are driven by alternating voltage. The behaviors of the both liquid crystals showed hysteresis. We also showed the trajectory of the polarization state observed through the super twisted nematic liquid crystal on the Poincare sphere.

  10. PERFORMANCE OF THE LEAD/LIQUID ARGON SHOWER COUNTER SYSTEM OF THE MARK II DETECTOR AT SPEAR

    SciTech Connect

    Abrams, G S; Blocker, C A; Briggs, D D; Carithers, W C; Dieterle, W E; Eaton, M W; Lankford, A J; Pang, C Y; Vella, E N; Breidenbach, M; Dorfan, J M; Hanson, G; Hitlin, D G; Jenni, P; Luth, V

    1980-05-01

    The shower counter system of the SLAC-LBL Mark II detector is a large lead/liquid argon system of the type pioneered by Willis and Radekal; however, it differs in most details and is much larger than other such detectors currently in operation, It contains, for example, 8000 liters of liquid argon and 3000 channels of low noise electronics, which is about eight times the size of the system of Willis et al. in the CERN ISR. This paper reports, with little reference to design, on the operation and performance of the Mark II system during approximately a year and a half of operation at the Stanford Linear Accelerator Center's e{sup +}-e{sup -} facility, SPEAR. The design and construction of the system have previously been described and a detailed discussion of all aspects -- design, construction, operation, and performance -- is in preparation.

  11. First results on light readout from the 1-ton ArDM liquid argon detector for dark matter searches

    NASA Astrophysics Data System (ADS)

    ArDM Collaboration; Amsler, C.; Badertscher, A.; Boccone, V.; Bueno, A.; Carmona-Benitez, M. C.; Creus, W.; Curioni, A.; Daniel, M.; Dawe, E. J.; Degunda, U.; Gendotti, A.; Epprecht, L.; Horikawa, S.; Kaufmann, L.; Knecht, L.; Laffranchi, M.; Lazzaro, C.; Lightfoot, P. K.; Lussi, D.; Lozano, J.; Marchionni, A.; Mavrokoridis, K.; Melgarejo, A.; Mijakowski, P.; Natterer, G.; Navas-Concha, S.; Otyugova, P.; de Prado, M.; Przewlocki, P.; Regenfus, C.; Resnati, F.; Robinson, M.; Rochet, J.; Romero, L.; Rondio, E.; Rubbia, A.; Scotto-Lavina, L.; Spooner, N. J. C.; Strauss, T.; Ulbricht, J.; Viant, T.

    2010-11-01

    ArDM-1t is the prototype for a next generation WIMP detector measuring both the scintillation light and the ionization charge from nuclear recoils in a 1-ton liquid argon target. The goal is to reach a minimum recoil energy of 30 keVr to detect recoiling nuclei. In this paper we describe the experimental concept and present results on the light detection system, tested for the first time in ArDM on the surface at CERN. With a preliminary and incomplete set of PMTs, the light yield at zero electric field is found to be between 0.3-0.5 phe/keVee depending on the position within the detector volume, confirming our expectations based on smaller detector setups.

  12. Comparison of element-specific capillary chromotography detectors for the identification of heteroatomic species in coal liquids

    SciTech Connect

    Mitchell, S.C.; Bartle, K.D.; Holden, K.M.L.

    1994-12-31

    A series of heteroatom-rich coal and coal-derived liquids have been analysed using gas chromatography (GC) in combination with three different element-selective detectors. Selected chromatograms, including a supercritical extract (Mequinenza lignite) and aromatic fractions isolated from coal tar pitch samples are presented. In each case a series of sulphur- and/or nitrogen-containing compounds have been identified using either flame photometric detection (GC/FID/FPD) or nitrogen-phosphorous detection (GC/FID/NPD) and the information compared with that obtained from a GC coupled to an atomic emission detector (GC-AED). Preliminary results have demonstrated the relative response characteristics of each detector and their respective ability to acquire qualitative and quantitative information in interfering background matrices. Further, due to the unique capabilities of GC-AED, a number of dual heteroatomic (sulphur-oxygen and nitrogen-oxygen) compounds have been identified.

  13. Operating the GridPix detector in dark matter search experiments

    NASA Astrophysics Data System (ADS)

    Schön, R.; Alfonsi, M.; Hemink, G.; Decowski, M. P.; van Bakel, N.; van der Graaf, H.

    2013-08-01

    The DARWIN (dark matter WIMP search with noble liquids) design study aims to use liquid argon and liquid xenon targets to look for nuclear recoils due to weakly interacting massive particles (WIMPs). To measure the recoil energy in dual-phase noble gas time projection chambers the combination of scintillation and ionisation detection is used to discriminate nuclear from electron recoils. Current experiments use an array of photomultiplier tubes to detect the primary scintillation and the ionisation electrons via secondary scintillation in the gas phase. Within the research framework for DARWIN, one candidate for an alternative direct charge readout is GridPix, a micro-pattern gaseous detector composed of a Micromegas-like amplification grid over the Timepix 65k pixel readout chip. It can achieve a single-electron detection efficiency of up to 98% and has thus great potential to identify the ionisation electrons in dark matter search experiments. The main challenges for this application are low outgassing, thermal robustness, and operation in pure (thus quencher-free) noble gas. To investigate its applicability we operated a GridPix detector in an argon cryostat. We proved GridPix's performance in pure argon. The gas amplification was confirmed in pure argon in the broad temperature range from 300 K down to 87 K. Additionally, we discuss results of thermal tests of GridPix devices at liquid xenon temperature in a dry nitrogen atmosphere.

  14. Reliable and well-controlled synthesis of noble metal nanoparticles by continuous wave laser ablation in different liquids for deposition of thin films with variable optical properties

    NASA Astrophysics Data System (ADS)

    Arakelyan, S. M.; Veiko, V. P.; Kutrovskaya, S. V.; Kucherik, A. O.; Osipov, A. V.; Vartanyan, T. A.; Itina, T. E.

    2016-06-01

    We report the results of continuous wave laser interactions with both gold and silver targets in the presence of different liquids (deionized water, ethanol, and glycerol). Upon moderate laser irradiation at wavelength of 1.06 nm during 30 min, nanoparticle colloids are shown to be formed with surprisingly narrow size distributions and average dispersion as small as 15-20 nm. The average particle sizes range between 8 and 52 nm for gold and between 20 and 107 nm for silver. This parameter is shown to be stable and well-controlled by such laser parameters as intensity and effective irradiation time, as well as by the choice of the liquid phase. The possibilities of an efficient control over the proposed synthesis techniques are discussed, and the results of a bimetallic Au-Ag structure deposition from the obtained colloids are presented. The formation of the extended arrays of gold and silver nanoparticles with controlled morphology is examined. The changes in the optical properties of the obtained thin films are found to depend on their morphology, in particular, on the particle size, and distance between them.

  15. Digital pulse shape discrimination methods for n-γ separation in an EJ-301 liquid scintillation detector

    NASA Astrophysics Data System (ADS)

    Wan, Bo; Zhang, Xue-Ying; Chen, Liang; Ge, Hong-Lin; Ma, Fei; Zhang, Hong-Bin; Ju, Yong-Qin; Zhang, Yan-Bin; Li, Yan-Yan; Xu, Xiao-Wei

    2015-11-01

    A digital pulse shape discrimination system based on a programmable module NI-5772 has been established and tested with an EJ-301 liquid scintillation detector. The module was operated by running programs developed in LabVIEW, with a sampling frequency up to 1.6 GS/s. Standard gamma sources 22Na, 137Cs and 60Co were used to calibrate the EJ-301 liquid scintillation detector, and the gamma response function was obtained. Digital algorithms for the charge comparison method and zero-crossing method have been developed. The experimental results show that both digital signal processing (DSP) algorithms can discriminate neutrons from γ-rays. Moreover, the zero-crossing method shows better n-γ discrimination at 80 keVee and lower, whereas the charge comparison method gives better results at higher thresholds. In addition, the figure-of-merit (FOM) for detectors of two different dimensions were extracted at 9 energy thresholds, and it was found that the smaller detector presented better n-γ separation for fission neutrons. Supported by National Natural Science Foundation of China (91226107, 11305229) and the Strategic Priority Research Program of the Chinese Academy of Sciences (XDA03030300)

  16. 77 FR 70159 - Marble River, LLC v. Noble Clinton Windpark I, LLC, Noble Ellenburg Windpark, LLC, Noble...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-11-23

    ... Energy Regulatory Commission Marble River, LLC v. Noble Clinton Windpark I, LLC, Noble Ellenburg Windpark..., Marble River, LLC (Marble River or Complainant) filed a formal complaint against Noble Clinton Windpark I... pay Marble River for headroom created by common system upgrade facilities that benefit Noble and...

  17. Noble metals in oncology

    PubMed Central

    Markowska, Anna; Jaszczyńska-Nowinka, Karolina; Lubin, Jolanta; Markowska, Janina

    2015-01-01

    Worldwide research groups are searching for anticancer compounds, many of them are organometalic complexes having platinum group metals as their active centers. Most commonly used cytostatics from this group are cisplatin, carboplatin and oxaliplatin. Cisplatin was used fot the first time in 1978, from this time many platinum derivatives were created. In this review we present biological properties and probable future clinical use of platinum, gold, silver, iridium and ruthenium derivatives. Gold derivative Auranofin has been studied extensively. Action of silver nanoparticles on different cell lines was analysed. Iridium isotopes are commonly used in brachyterapy. Ruthenium compound new anti-tumour metastasis inhibitor (NAMI-A) is used in managing lung cancer metastases. Electroporation of another ruthenium based compound KP1339 was also studied. Most of described complexes have antiproliferative and proapoptotic properties. Further studies need to be made. Nevertheless noble metal based chemotherapheutics and compounds seem to be an interesting direction of research. PMID:26557773

  18. Liquid phase epitaxial growth and characterization of germanium far infrared blocked impurity band detectors

    SciTech Connect

    Bandaru, Jordana

    2001-01-01

    Germanium Blocked Impurity Band (BIB) detectors require a high purity blocking layer (< 1013 cm-3) approximately 1 mm thick grown on a heavily doped active layer (~ 1016cm-3) approximately 20 mm thick. Epilayers were grown using liquid phase epitaxy (LPE) of germanium out of lead solution. The effects of the crystallographic orientation of the germanium substrate on LPE growth modes were explored. Growth was studied on substrates oriented by Laue x-ray diffraction between 0.02° and 10° from the {111} toward the {100}. Terrace growth was observed, with increasing terrace height for larger misorientation angles. It was found that the purity of the blocking layer was limited by the presence of phosphorus in the lead solvent. Unintentionally doped Ge layers contained ~1015 cm-3 phosphorus as determined by Hall effect measurements and Photothermal Ionization Spectroscopy (PTIS). Lead purification by vacuum distillation and dilution reduced the phosphorus concentration in the layers to ~ 1014 cm-3 but further reduction was not observed with successive distillation runs. The graphite distillation and growth components as an additional phosphorus source cannot be ruled out. Antimony (~1016 cm-3) was used as a dopant for the active BIB layer. A reduction in the donor binding energy due to impurity banding was observed by variable temperature Hall effect measurements. A BIB detector fabricated from an Sb-doped Ge layer grown on a pure substrate showed a low energy photoconductive onset (~6 meV). Spreading resistance measurements on doped layers revealed a nonuniform dopant distribution with Sb pile-up at the layer surface, which must be removed by chemomechanical polishing. Sb diffusion into the pure substrate was observed by Secondary Ion Mass Spectroscopy (SIMS) for epilayers grown at 650 C. The Sb concentration at the interface dropped by an order of magnitude

  19. Noble gases in the moon

    NASA Technical Reports Server (NTRS)

    Manuel, O. K.; Srinivasan, B.; Hennecke, E. W.; Sinclair, D. E.

    1972-01-01

    The abundance and isotopic composition of helium, neon, argon, krypton, and xenon which were released by stepwise heating of lunar fines (15601.64) and (15271.65) were measured spectrometrically. The results of a composition of noble gases released from the lunar fines with noble gases in meteorites and in the earth are presented along with the isotopic composition of noble gases in lunar fines, in meteorites, and in the atmosphere. A study of two isotopically distinct components of trapped xenon in carbonaceous chondrites is also included.

  20. Noble gas excimer scintillation following neutron capture in boron thin films

    SciTech Connect

    McComb, Jacob C.; Al-Sheikhly, Mohamad; Coplan, Michael A.; Thompson, Alan K.; Vest, Robert E.; Clark, Charles W.

    2014-04-14

    Far-ultraviolet scintillation signals have been measured in heavy noble gases (argon, krypton, xenon) following boron-neutron capture ({sup 10}B(n,α){sup 7}Li) in {sup 10}B thin films. The observed scintillation yields are comparable to the yields from some liquid and solid neutron scintillators. At noble gas pressures of 107 kPa, the number of photons produced per neutron absorbed following irradiation of a 1200 nm thick {sup 10}B film was 14 000 for xenon, 11 000 for krypton, and 6000 for argon. The absolute scintillation yields from the experimental configuration were calculated using data from (1) experimental irradiations, (2) thin-film characterizations, (3) photomultiplier tube calibrations, and (4) photon collection modeling. Both the boron films and the photomultiplier tube were characterized at the National Institute of Standards and Technology. Monte Carlo modeling of the reaction cell provided estimates of the photon collection efficiency and the transport behavior of {sup 10}B(n,α){sup 7}Li reaction products escaping the thin films. Scintillation yields increased with gas pressure due to increased ionization and excitation densities of the gases from the {sup 10}B(n,α){sup 7}Li reaction products, increased frequency of three-body, excimer-forming collisions, and reduced photon emission volumes (i.e., larger solid angle) at higher pressures. Yields decreased for thicker {sup 10}B thin films due to higher average energy loss of the {sup 10}B(n,α){sup 7}Li reaction products escaping the films. The relative standard uncertainties in the measurements were determined to lie between 14% and 16%. The observed scintillation signal demonstrates that noble gas excimer scintillation is promising for use in practical neutron detectors.

  1. Neutrinos from failed supernovae at future water and liquid argon detectors

    NASA Astrophysics Data System (ADS)

    Keehn, James G.; Lunardini, Cecilia

    2012-02-01

    We discuss the diffuse flux of electron neutrinos and antineutrinos from cosmological failed supernovae, stars that collapse directly into a black hole with no explosion. This flux has a hotter energy spectrum compared to the flux from regular, neutron star-forming collapses and therefore it dominates the total diffuse flux from core collapses above 20-45 MeV of neutrino energy. Reflecting the features of the originally emitted neutrinos, the flux of νe and ν¯e at Earth is larger when the survival probability of these species is larger, and also when the equations of state of nuclear matter are stiffer. In the 19-29 MeV energy window, the flux from failed supernovae is substantial, ranging from ˜7% to a dominant fraction of the total flux from all core collapses. It can be as large as ϕe¯BH=0.38s-1cm-2 for ν¯e and as large as ϕeBH=0.28s-1cm-2 for νe, normalized to a local rate of core collapses of Rcc(0)=10-4yr-1Mpc-3. In 5 years, a 0.45 Mt water Cherenkov detector should see ˜5-65 events from failed supernovae, while up to ˜160 events are expected for the same mass with Gadolinium added. A 0.1 Mt liquid argon experiment should record ˜1-11 events. Signatures of neutrinos from failed supernovae are the enhancement of the total rates of events from core collapses (up to a factor of ˜2) and the appearance of high energy tails in the event spectra.

  2. Neutrinos from failed supernovae at future water and liquid argon detectors

    SciTech Connect

    Keehn, James G.; Lunardini, Cecilia

    2012-02-01

    We discuss the diffuse flux of electron neutrinos and antineutrinos from cosmological failed supernovae, stars that collapse directly into a black hole with no explosion. This flux has a hotter energy spectrum compared to the flux from regular, neutron star-forming collapses and therefore it dominates the total diffuse flux from core collapses above 20–45 MeV of neutrino energy. Reflecting the features of the originally emitted neutrinos, the flux of νe and $\\bar{v}$e at Earth is larger when the survival probability of these species is larger, and also when the equations of state of nuclear matter are stiffer. In the 19–29 MeV energy window, the flux from failed supernovae is substantial, ranging from ~7% to a dominant fraction of the total flux from all core collapses. It can be as large as Φ$\\bar{e}$BH=0.38 s-1 cm-2 for $\\bar{v}$e and as large as Φ$\\bar{e}$BH=0.28 s-1 cm-2 for νe, normalized to a local rate of core collapses of Rcc(0)=10-4 yr-1 Mpc-3. In 5 years, a 0.45 Mt water Cherenkov detector should see ~5–65 events from failed supernovae, while up to ~160 events are expected for the same mass with Gadolinium added. A 0.1 Mt liquid argon experiment should record ~1–11 events. Signatures of neutrinos from failed supernovae are the enhancement of the total rates of events from core collapses (up to a factor of ~2) and the appearance of high energy tails in the event spectra.

  3. Single-bubble sonoluminescence from noble gases.

    PubMed

    Yasui, K

    2001-03-01

    Single-bubble sonoluminescence (SBSL) from noble gases in water is studied theoretically in order to clarify the reason of the distinguished feature that the luminescence is strong for all noble gases, while the other systems of cavitation luminescence are greatly enhanced by the presence of the heavy noble gas(xenon). It is clarified that in spite of the larger thermal conductivity of lighter noble gases the maximum temperature in a SBSL bubble of lighter noble gases is higher due both to the segregation of water vapor and noble gas inside a SBSL bubble and the stronger acoustic drive of a SBSL bubble of lighter noble gases.

  4. Single-bubble sonoluminescence from noble gases

    NASA Astrophysics Data System (ADS)

    Yasui, Kyuichi

    2001-03-01

    Single-bubble sonoluminescence (SBSL) from noble gases in water is studied theoretically in order to clarify the reason of the distinguished feature that the luminescence is strong for all noble gases, while the other systems of cavitation luminescence are greatly enhanced by the presence of the heavy noble gas(xenon). It is clarified that in spite of the larger thermal conductivity of lighter noble gases the maximum temperature in a SBSL bubble of lighter noble gases is higher due both to the segregation of water vapor and noble gas inside a SBSL bubble and the stronger acoustic drive of a SBSL bubble of lighter noble gases.

  5. Applicability of Monte-Carlo Simulation to Equipment Design of Radioactive Noble Gas Monitor

    NASA Astrophysics Data System (ADS)

    Sakai, Hirotaka; Hattori, Kanako; Umemura, Norihiro

    In the nuclear facilities, radioactive noble gas is continuously monitored by using the radioactive noble gas monitor with beta-sensitive plastic scintillation radiation detector. The detection efficiency of the monitor is generally calibrated by using a calibration loop and standard radioactive noble gases such as 85Kr. In this study, the applicability of PHITS to the equipment design of the radioactive noble gas monitor was evaluated by comparing the calculated results to the test results obtained by actual calibration loop tests to simplify the radiation monitor design evaluation. It was confirmed that the calculated results were well matched to the test results of the monitor after the modeling. In addition, the key parameters for equipment design, such as thickness of detector window or depth of the sampler, were also specified and evaluated.

  6. Particle Detectors: Research and Development at CERN

    SciTech Connect

    Fabjan, C. W.

    2008-04-21

    Over the past 15 years a worldwide Detector R and D Programme has made the LHC experiments possible. These experiments operate at a new level of event rate and detection capabilities. Based on these advances, Detector R and D is continuing at CERN in close collaboration with University and Research Institutes. Several main directions are being pursued for solid-state and gaseous tracking devices, advanced crystal and noble liquid calorimetry, particle identification methods, and advanced signal-processing techniques. This effort is directed towards experiments at even higher collision rates at the LHC, the requirements for the next generation of linear electron-positron colliders and for applications outside particle physics, such as medical diagnostics instrumentation. We shall illustrate this challenging, stimulating and creative programme with examples and show how these developments are taking place in close collaboration between CERN and institutions around the globe.

  7. The ArDM, a ton-scale liquid argon experiment for direct dark matter detection

    NASA Astrophysics Data System (ADS)

    Otyugova, P.; Ar DM Collaboration

    2008-07-01

    The ArDM project aims at developing and operating large noble liquid detectors to search for direct evidence of Weakly Interacting Massive Particles (WIMP) as Dark Matter in the Universe. The initial goal is to design, assemble and operate an approximately 1 ton liquid argon prototype based on the double-phase detection principle to demonstrate the feasibility of a ton-scale experiment with the required performance to efficiently detect and sufficiently discriminate backgrounds for a successful WIMP detection. The detector will independently measure the primary scintillation light and the ionization charge. This paper will mainly describe the concept, R&D results and status of the charge read out system.

  8. Performance of the High Resolution, Multi-collector Helix MC Plus Noble Gas Mass Spectrometer at the Australian National University

    NASA Astrophysics Data System (ADS)

    Zhang, Xiaodong; Honda, Masahiko; Hamilton, Doug

    2016-12-01

    Performance of the Helix MC Plus noble gas mass spectrometer installed at the Australian National University (ANU) is reported. Results for sensitivity, mass discrimination and their linearity against partial pressure of noble gases, and mass resolution of the mass spectrometer are presented, and the results are compared with those of conventional noble gas mass spectrometers. The application of the five detectors on the Helix MC Plus in measuring various noble gas isotopes in multi-collector modes and the integration of the software drivers of peripheral hardware devices into the controlling program Qtegra of the mass spectrometer are discussed. High mass resolution (>1800) and mass resolving power (>8000) make this mass spectrometer unique in noble gas cosmo-geochemistry. It provides the capability to measure isobaric interference-free noble gas isotopes in multi-collector mode, significantly improves the accuracy to determine isotopic ratios, and greatly increases the efficiency of data acquisition.

  9. Resonance ionization spectroscopy: counting noble-gas atoms

    SciTech Connect

    Hurst, G.S.; Payne, M.G.; Chen, C.H.; Willis, R.D.; Lehmann, B.E.; Kramer, S.D.

    1981-06-01

    New work on the counting of noble gas atoms, using lasers for the selective ionization and detectors for counting individual particles (electrons or positive ions) is reported. When positive ions are counted, various kinds of mass analyzers (magnetic, quadrupole, or time-of-flight) can be incorporated to provide A selectivity. It is shown that a variety of interesting and important applications can be made with atom-counting techniques which are both atomic number (Z) and mass number (A) selective.

  10. Surface-enhanced resonance Raman spectroscopy as an ancillary high-performance liquid chromatography detector for nitrophenol compounds

    SciTech Connect

    Ni, F.; Thomas, L.; Cotton, T.M. )

    1989-04-15

    In this study, the potential application of surface-enhanced resonance Raman scattering (SERRS) spectroscopy as an off-line secondary detector for HPLC has been evaluated. Four nitrophenol compounds, 2-nitrophenol, 4-nitrophenol, 2,4-dinitrophenol, and 4,6-dinitrocresol were separated by isocratic reverse-phase high-performance liquid chromatography (RP-HPLC) and monitored with a conventional UV detector. Resonance Raman (RR) and SERRS spectroscopy were next used to provide the required specificity for distinguishing the nitrophenol compounds. The SERRS detection limit for both 2-nitrophenol and 4-nitrophenol was calculated to be 14 ppb and that for 2,4-dinitrophenol and 4,6-dinitrocresol was estimated to lie near the parts-per-billion level as well. This detection limit is 2-3 orders of magnitude lower than that obtained by RR spectroscopy.

  11. Results of low energy background measurements with the Liquid Scintillation Detector (LSD) of the Mont Blanc Laboratory

    NASA Technical Reports Server (NTRS)

    Aglietta, M.; Badino, G.; Bologna, G. F.; Castagnoli, C.; Fulgione, W.; Galeotti, P.; Saavedra, O.; Trinchero, G. C.; Vernetto, S.; Dadykin, V. L.

    1985-01-01

    The 90 tons liquid scintillation detector (LSD) is fully running since October 1984, at a depth of 5,200 hg/sq cm of standard rock underground. The main goal is to search for neutrino bursts from collapsing stars. The experiment is very sensitive to detect low energy particles and has a very good signature to gamma-rays from (n,p) reaction which follows the upsilon e + p yields n + e sup + neutrino capture. The analysis of data is presented and the preliminary results on low energy measurements are discussed.

  12. A novel on-line gold nanoparticle-catalyzed luminol chemiluminescence detector for high-performance liquid chromatography.

    PubMed

    Zhang, Qun Lin; Wu, Liang; Lv, Chen; Zhang, Xiao Yue

    2012-06-15

    A novel on-line gold nanoparticle-catalyzed luminol-H(2)O(2) chemiluminescence (CL) detector for high-performance liquid chromatography (HPLC) was established, in which gold nanoparticles were produced by the on-line reaction of H(2)O(2), NaHCO(3)-Na(2)CO(3) (buffer solution of luminol), and HAuCl(4). Eight phenolic compounds (gallic acid, protocatechuic acid, protocatechuic aldehyde, 2,5-dihydroxybenzoic acid, caffeic acid, 2,3-dihydroxybenzoic acid, (+)-catechin, and (-)-epicatechin) were chosen as the model compounds. Every separated phenolic compound in the column eluent strongly enhanced the CL signal of on-line gold nanoparticle-catalyzed luminol system. The CL and UV-visible absorption spectra and transmission electron microscopy studies were carried out, and the CL enhancement mechanism was ascribed to that the presence of phenolic compound promoted the on-line formation of 38-nm-diameter gold nanoparticles, which better catalyzed the luminol-H(2)O(2) CL reaction. The effects of methanol and phosphoric acid in the proposed HPLC configuration were performed by two gradient elution programs, and the baseline profile revealed that on-line gold nanoparticle-catalyzed luminol-H(2)O(2) CL detector had better compatibility than 38 nm gold colloids-luminol-H(2)O(2) CL detector. The proposed CL detector exhibits excellent analytical performance with the low detection limit (S/N=3) of 0.53-0.97 ng/mL (10.6-19.4 pg) phenolic compounds, and offers a new strategy for developing on-line nanoparticle-catalyzed CL detector for HPLC with sensitive analysis.

  13. Application of a BC501A Liquid Scintillation Detector with a Gain Stabilization System on the EAST Tokamak

    NASA Astrophysics Data System (ADS)

    Peng, Xingyu; Chen, Zhongjing; Du, Tengfei; Hu, Zhimeng; Ge, Lijian; Chen, Jinxiang; Li, Xiangqing; Fan, Tieshuan

    2016-01-01

    A 2” × 2” BC501A liquid scintillation detector with a gain stabilization system is developed and applied to neutron and γ-ray measurement on the EAST tokamak. Energy calibration of a liquid scintillator using a fast coincidence method is presented and compared with the Monte Carlo simulation. Determination of the proton light output function of the BC501A is presented. Results from dedicated experiments with an Am-Be neutron source, γ source and quasi-monoenergetic neutron beams, and from measurements on EAST tokamak are presented and discussed. supported by the National Magnetic Confinement Fusion Science Program of China (Nos. 2013GB106004 and 2012GB101003) and National Natural Science Foundation of China (No. 91226102)

  14. An Air Noble Gas Component in the Mantle

    NASA Astrophysics Data System (ADS)

    Sarda, P.

    2005-12-01

    atmosphere there [3]. The upper mantle would thus be a marble cake and, on melting, the recycled, more fertile component would melt first. The first vesicles would then bear the atmospheric noble gas component, while the next liquids would be produced more from the peridotite matrix, and would eventually generate vesicles with mantle noble gases (40Ar/36Ar > 10,000, 129Xe/130Xe > 7, . . .). A simple model for this double-step melting, using classical equations for trace elements and assuming that vesicles appear as soon as melt is generated, reproduces the 40Ar/36Ar pattern seen on step-crushing of popping rocks, with reasonable values for partition coefficients and proportion of recycled matter. Although this model remains to be investigated, part of the atmospheric noble gases in oceanic basalts may be recycled in origin. This hypothesis simply explains several of the observations above. Especially, it can reconcile noble gas and non-gaseous isotopic tracers by allowing recycled noble gases to occur together with mantle noble gases, in vesicles with different sizes. [1] C.J. Ballentine and D.N. Barfod, The origin of air-like noble gases in MORB and OIB, Earth Planet Sci. Lett. 180, 39-48, 2000. [2] Ph. Sarda, Surface noble gas recycling to the terrestrial mantle, Earth Planet Sci. Lett. 228, 49-63, 2004. [3] T. Staudacher and C.J. Allegre, Recycling of oceanic crust and sediments: the noble gas subduction barrier, Earth Planet. Sci. Lett. 89, 173-183, 1988.

  15. Oxygen adsorption at noble metal/TiO2 junctions

    NASA Astrophysics Data System (ADS)

    Hossein-Babaei, F.; Alaei-Sheini, Navid; Lajvardi, Mehdi M.

    2016-03-01

    Electric conduction in titanium dioxide is known to be oxygen sensitive and the conductivity of a TiO2 ceramic body is determined mainly by the concentration of its naturally occurring oxygen vacancy. Recently, fabrications and electronic features of a number of noble metal/TiO2-based electronic devices, such as solar cells, UV detectors, gas sensors and memristive devices have been demonstrated. Here, we investigate the effect of oxygen adsorption at the noble metal/TiO2 junction in such devices, and show the potentials of these junctions in chemical sensor fabrication. The polycrystalline, poly-phase TiO2 layers are grown by the selective and controlled oxidation of titanium thin films vacuum deposited on silica substrates. Noble metal thin films are deposited on the oxide layers by physical vapor deposition. Current-voltage (I-V) diagrams of the fabricated devices are studied for Ag/, Au/, and Pt/TiO2 samples. The raw samples show no junction energy barrier. After a thermal annealing in air at 250° C, I-V diagrams change drastically. The annealed samples demonstrate highly non-linear I-V indicating the formation of high Schottky energy barriers at the noble metal/TiO2 junctions. The phenomenon is described based on the effect of the oxygen atoms adsorbed at the junction.

  16. Determination of 3-nitrotyrosine by high-pressure liquid chromatography with a dual-mode electrochemical detector.

    PubMed

    Sodum, R S; Akerkar, S A; Fiala, E S

    2000-05-01

    3-Nitrotyrosine, a product of tyrosine nitration, is useful as a marker for the generation of reactive nitrogen oxide species with short half-lives such as peroxynitrite. A reverse-phase high-pressure liquid chromatographic method using a dual-mode electrochemical detector in series with a photodiode array detector has been developed to determine the levels of 3-nitrotyrosine in biological samples. The principle of this method involves reduction of 3-nitrotyrosine at an upstream gold amalgam electrode and oxidation of the resulting product(s) at a downstream glassy carbon electrode. 3-Nitrotyrosine is quantified by the amount of the current generated at the downstream electrode, and a femtomole detection level can be achieved. The disappearance of the corresponding peak when the electrochemical detector is used only in the single oxidative mode provides additional evidence for the identity of 3-nitrotyrosine in the sample. Tyrosine from the same sample is determined by its UV absorption at 280 nm, thus eliminating the need for an internal standard. With this method a dose-dependent increase of 3- to 10-fold in the levels of protein 3-nitrotyrosine was observed in the blood plasma, and a 2- to 4-fold increase in the lung cytosols, of rats treated with the lung carcinogen and nitrating agent tetranitromethane.

  17. INGAS: Iranian Noble Gas Analyzing System for radioxenon measurement

    NASA Astrophysics Data System (ADS)

    Doost-Mohammadi, V.; Afarideh, H.; Etaati, G. R.; Safari, M. J.; Rouhi, H.

    2016-03-01

    In this article, Iranian Noble Gas Analyzing System (INGAS) will be introduced. This system is based on beta-gamma coincidence technique and consists of a well-type NaI(Tl) as gamma or X radiation detector and a cylindrical plastic scintillator to detect beta or conversion electron. Standard NIM modules were utilized to detect coincidence events of detectors. Both the beta and gamma detectors were appropriately calibrated. The efficiency curve of gamma detector for volume geometry was obtained by comparing the results of gamma point sources measurements and simulations of GATE V7.0 Monte Carlo code. The performance of detection system was checked by injection of 222Rn and 131mXe gaseous source in the detection cell. The minimum detectable activity of the system for 133Xe is 1.240±0.024 mBq for 24 h measurement time.

  18. Study of nuclear recoils in liquid argon with monoenergetic neutrons

    NASA Astrophysics Data System (ADS)

    Regenfus, C.; Allkofer, Y.; Amsler, C.; Creus, W.; Ferella, A.; Rochet, J.; Walter, M.

    2012-07-01

    In the framework of developments for liquid argon dark matter detectors we assembled a laboratory setup to scatter neutrons on a small liquid argon target. The neutrons are produced mono-energetically (Ekin = 2.45 MeV) by nuclear fusion in a deuterium plasma and are collimated onto a 3" liquid argon cell operating in single-phase mode (zero electric field). Organic liquid scintillators are used to tag scattered neutrons and to provide a time-of-flight measurement. The setup is designed to study light pulse shapes and scintillation yields from nuclear and electronic recoils as well as from alpha particles at working points relevant for dark matter searches. Liquid argon offers the possibility to scrutinise scintillation yields in noble liquids with respect to the population strength of the two fundamental excimer states. Here we present experimental methods and first results from recent data towards such studies.

  19. Two dimensional assisted liquid chromatography - a chemometric approach to improve accuracy and precision of quantitation in liquid chromatography using 2D separation, dual detectors, and multivariate curve resolution.

    PubMed

    Cook, Daniel W; Rutan, Sarah C; Stoll, Dwight R; Carr, Peter W

    2015-02-15

    Comprehensive two-dimensional liquid chromatography (LC×LC) is rapidly evolving as the preferred method for the analysis of complex biological samples owing to its much greater resolving power compared to conventional one-dimensional (1D-LC). While its enhanced resolving power makes this method appealing, it has been shown that the precision of quantitation in LC×LC is generally not as good as that obtained with 1D-LC. The poorer quantitative performance of LC×LC is due to several factors including but not limited to the undersampling of the first dimension and the dilution of analytes during transit from the first dimension ((1)D) column to the second dimension ((2)D) column, and the larger relative background signals. A new strategy, 2D assisted liquid chromatography (2DALC), is presented here. 2DALC makes use of a diode array detector placed at the end of each column, producing both multivariate (1)D and two-dimensional (2D) chromatograms. The increased resolution of the analytes provided by the addition of a second dimension of separation enables the determination of analyte absorbance spectra from the (2)D detector signal that are relatively pure and can be used to initiate the treatment of data from the first dimension detector using multivariate curve resolution-alternating least squares (MCR-ALS). In this way, the approach leverages the strengths of both separation methods in a single analysis: the (2)D detector data is used to provide relatively pure analyte spectra to the MCR-ALS algorithm, and the final quantitative results are obtained from the resolved (1)D chromatograms, which has a much higher sampling rate and lower background signal than obtained in conventional single detector LC×LC, to obtain accurate and precise quantitative results. It is shown that 2DALC is superior to both single detector selective or comprehensive LC×LC and 1D-LC for quantitation of compounds that appear as severely overlapped peaks in the (1)D chromatogram - this is

  20. A Low-Cost Liquid-Chromatography System Using a Spectronic 20-Based Detector.

    ERIC Educational Resources Information Center

    Jezorek, John R.; And Others

    1986-01-01

    Describes the design and evaluation of a Spectronic 20-based detector as well as a simple system for postcolumn derivatization useful for metal-ion chromatographic detection. Both detection and derivatization can be performed in the ultra-violet (UV) mode using a low-cost UV-visible spectrophotometer and UV-region derivatization reagents. (JN)

  1. Environmental pressure reduction with a new method of noble metal recovery

    NASA Astrophysics Data System (ADS)

    Filippova, EV

    2017-02-01

    Discoveries in the area of hydrometallurgy of noble metals can be of use in metal recovery from low-grade solutions and slurries, including liquid tailings. Efficiency of noble metal recovery and reduction in mining waste is gained owing to utilization of two forms of ion-exchange sorbent, including OH‑ for recovery of cyanic compounds of gold and cyanides, which allows abating burden on natural systems.

  2. Non-intrusive ultrasonic liquid-in-line detector for small diameter tubes

    DOEpatents

    Piper, Thomas C.

    1982-01-01

    An arrangement for deleting liquid in a line, using non-intrusive ultrasonic techniques is disclosed. In this arrangement, four piezoelectric crystals are arranged in pairs about a 0.072 inch o.d. pipe. An ultrasonic tone burst is transmitted along the pipe, between crystal pairs, and the amplitude of the received tone burst indicates the absence/presence of liquid in the pipe.

  3. Liquid xenon purification, de-radonation (and de-kryptonation)

    SciTech Connect

    Pocar, Andrea

    2015-08-17

    Liquid xenon detectors are at the forefront of rare event physics, including searches for neutrino-less double beta decay and WIMP dark matter. The xenon for these experiments needs to be purified from chemical impurities such as electronegative atoms and molecules, which absorb ionization electrons, and VUV (178 nm) scintillation light-absorbing chemical species. In addition, superb purification from radioactive impurities is required. Particularly challenging are radioactive noble isotopes ({sup 85}Kr,{sup 39,42}Ar,{sup 220,222}Rn). Radon is a particularly universal problem, due to the extended decay sequence of its daughters and its ubiquitous presence in detector materials. Purification and de-radonation of liquid xenon are addressed with particular focus on the experience gained with the EXO-200 neutrino-less double beta decay detector.

  4. Microfabricated refractive index gradient based detector for reversed-phase liquid chromatography with mobile phase gradient elution.

    PubMed

    McBrady, Adam D; Synovec, Robert E

    2006-02-10

    Typical refractive index (RI) detectors for liquid chromatography (LC) are not well suited to application with mobile phase gradient elution, due to the difficulty in correcting for the detected baseline shift during the gradient. We report a sensitive, highly reproducible, microfabricated refractive index gradient (micro-RIG) detector that performs well with mobile phase gradient elution LC. Since the micro-RIG signal remains on-scale throughout the mobile phase gradient, one can apply a baseline correction procedure. We demonstrate that by collecting two mobile phase gradient blanks and subtracting one of them from the other, a reproducible, flat baseline is achieved. Therefore, subtracting a blank from a separation provides a baseline corrected chromatogram with reasonably high signal-to-noise ratio for eluting analytes. The micro-RIG detector uses a collimated diode laser beam to optically probe a RIG formed perpendicular to the laminar flow direction within a microfabricated borosilicate glass chip. The chip-based design of the detector is suitable for either traditional bench-top or LC-on-a-chip technologies. We report reversed phase high performance liquid chromatography (RP-HPLC) separations of proteins and polymers, over mobile phase gradient conditions of 67% A:33% B to 3% A:97% B by volume, where A is 96% methanol:3.9% water:0.1% trifluoroacetic acid (TFA), and B is 3.9% methanol:96% water:0.1% TFA. The separations were performed on a Jupiter 5 mu C4 300 A 150 mm x 1.0 mm Phenomenex column at a flow rate of 20 microl/min. Viscosity changes during the mobile phase gradient separation are found to shift the on-chip merge position of the detected concentration gradient (i.e., RIG), in a reproducible fashion. However, this viscosity effect makes detection sensitivity vary throughout the mobile phase gradient, due to moving the optimized position of the probe beam in relation to the analyte concentration gradient being probed. None-the-less, consistent limits

  5. Ethanol Concentration in 56 Refillable Electronic Cigarettes Liquid Formulations Determined by Headspace Gas Chromatography with Flame Ionization Detector (HS-GC-FID).

    PubMed

    Poklis, Justin L; Wolf, Carl E; Peace, Michelle R

    2017-03-23

    Personal battery powered vaporizers or electronic cigarettes were developed as an alternative to traditional cigarettes. The modern electronic cigarettes were patented in 2004 by Hon Lik in China. In May 2016, the US Food and Drug Administration (FDA) imposed regulatory statutes on e-cigarettes and their liquid formulations (e-liquids); prior to that, they were unregulated. E-liquids are typically composed of propylene glycol and/or glycerin, flavoring component(s), and active ingredient(s), such as nicotine. Fifty-six commercially available e-liquids, purchased from various sources, contained a variety of flavors and active ingredients. A headspace gas chromatography with flame ionization detector HS-GC-FID method was used to analyze these e-liquids for volatiles content. Only one of the e-liquids listed ethanol as a component. A headspace gas chromatography with flame ionization detector HS-GC-FID method was used to analyze the e-liquids. The chromatographic separation of volatiles was performed on a Restek BAC-1 column. A linear calibration was generated for ethanol with limits of detection and quantification (LOD/LOQ) of 0.05 mg/mL. Ethanol concentrations in the fifty-six e-liquids ranged from none detected to 206 mg/mL. The ethanol determined in these products may have been used in flavorants or a solvent; the reason for inclusion cannot be fully ascertained. The implications of vaporizing ethanol as an e-liquid component are unknown.

  6. The use of Element-Specific Detectors Coupled with High-Performance Liquid Chromatographs.

    DTIC Science & Technology

    1981-11-04

    approach to determining the amount of various chelating agents in solution, Jones and Manahan reacted the indicator metal, A 20 copper(II) with a...latter two cases, GFAA was employed as the element specific detector. Jones and Manahan employing a high performance absorption column directly...Chromatogr. Sci., 17: 395 (1979). 35. D. R. Jones, IV and S. E. Manahan , Anal. Chem., 48: 1897 (1976). 36. D. R. Jones, IV and S. E. Manahan , Anal. Chem

  7. Noble gas trapping by laboratory carbon condensates

    NASA Technical Reports Server (NTRS)

    Niemeyer, S.; Marti, K.

    1982-01-01

    Trapping of noble gases by carbon-rich matter was investigated by synthesizing carbon condensates in a noble gas atmosphere. Laser evaporation of a solid carbon target yielded submicron grains which proved to be efficient noble gas trappers (Xe distribution coefficients up to 13 cu cm STP/g-atm). The carbon condensates are better noble gas trappers than previously reported synthetic samples, except one, but coefficients inferred for meteoritic acid-residues are still orders of magnitude higher. The trapped noble gases are loosely bound and elementally strongly fractionated, but isotopic fractionations were not detected. Although this experiment does not simulate nebular conditions, the results support the evidence that carbon-rich phases in meteorites may be carriers of noble gases from early solar system reservoirs. The trapped elemental noble gas fractionations are remarkably similar to both those inferred for meteorites and those of planetary atmospheres for earth, Mars and Venus.

  8. Gamma-thermometer-based reactor-core liquid-level detector. [PWR

    SciTech Connect

    Burns, T.J.

    1981-06-16

    A system is provided which employs a modified gamma thermometer for determining the liquid coolant level within a nuclear reactor core. The gamma thermometer which normally is employed to monitor local core heat generation rate (reactor power), is modified by thermocouple junctions and leads to obtain an unambiguous indication of the presence or absence of coolant liquid at the gamma thermometer location. A signal processor generates a signal based on the thermometer surface heat transfer coefficient by comparing the signals from the thermocouples at the thermometer location. The generated signal is a direct indication of loss of coolant due to the change in surface heat transfer when coolant liquid drops below the thermometer location. The loss of coolant indication is independent of reactor power at the thermometer location. Further, the same thermometer may still be used for the normal power monitoring function.

  9. Quantification of triacylglycerol molecular species in cocoa butter using high-performance liquid chromatography equipped with nano quantity analyte detector.

    PubMed

    Beppu, Fumiaki; Nagai, Toshiharu; Yoshinaga, Kazuaki; Mizobe, Hoyo; Kojima, Koichi; Gotoh, Naohiro

    2013-01-01

    Triacylglycerol (TAG) molecular species were quantified through high-performance liquid chromatography (HPLC) equipped with a nano quantity analyte detector (NQAD). TAG standard compounds, i.e., 1,3-dipalmitoyl-2-oleoylglycerol (β-POP), 1-palmitoyl-2-oleoyl-3-stearoyl-rac-glycerol (β-POS), and 1,3-distearoyl-2-oleoylglycerol (β-SOS), and natural cocoa butter were used for analyses. NQAD gave the first order equation passing through the origin for all TAG standard compounds. TAG molecular species in cocoa butter were quantified using the calibration curves and the obtained values were almost the same as the reported ones of conventional cocoa butter. Furthermore, a recovery test was also carried out and the values were almost 100. Therefore, HPLC-NQAD can be successfully used for the quantification of TAG molecular species in natural fats and oils.

  10. DETECTORS AND EXPERIMENTAL METHODS: Measurement of the neutron spectrum of a Pu-C source with a liquid scintillator

    NASA Astrophysics Data System (ADS)

    Wang, Song-Lin; Huang, Han-Xiong; Ruan, Xi-Chao; Li, Xia; Bao, Jie; Nie, Yang-Bo; Zhong, Qi-Ping; Zhou, Zu-Ying; Kong, Xiang-Zhong

    2009-05-01

    The neutron response function for a BC501A liquid scintillator (LS) has been measured using a series of monoenergetic neutrons produced by the p-T reaction. The proton energies were chosen such as to produce neutrons in the energy range of 1 to 20 MeV. The principles of the technique of unfolding a neutron energy spectrum by using the measured neutron response function and the measured Pulse Height (PH) spectrum is briefly described. The PH spectrum of neutrons from the Pu-C source, which will be used for the calibration of the reactor antineutrino detectors for the Daya Bay neutrino experiment, was measured and analyzed to get the neutron energy spectrum. Simultaneously the neutron energy spectrum of an Am-Be source was measured and compared with other measurements as a check of the result for the Pu-C source. Finally, an error analysis and a discussion of the results are given.

  11. Design and construction of a cryogenic distillation device for removal of krypton for liquid xenon dark matter detectors.

    PubMed

    Wang, Zhou; Bao, Lei; Hao, Xihuan; Ju, Yonglin

    2014-01-01

    Liquid xenon (Xe) is one of the commendable detecting media for the dark matter detections. However, the small content of radioactive krypton-85 ((85)Kr) always exists in the commercial xenon products. An efficient cryogenic distillation system to remove this krypton (Kr) from commercial xenon products has been specifically designed, developed, and constructed in order to meet the requirements of the dark matter experiments with high- sensitivity and low-background. The content of krypton in regular commercial xenon products can be reduced from 10(-9) to 10(-12), with 99% xenon collection efficiency at maximum flow rate of 5 kg/h (15SLPM). The purified xenon gases produced by this distillation system can be used as the detecting media in the project of Panda X, which is the first dark matter detector developed in China.

  12. The uncertainty analysis on energy scale due to the variation of W value for liquid xenon dark matter detector

    NASA Astrophysics Data System (ADS)

    Wang, Lu; Mei, Dongming; Cubed Collaboration

    2016-03-01

    The average energy expended per electron-ion pair, W value, is critical in understanding a liquid xenon detector energy response to low energy recoils. The reduction of scintillation and ionization yield for electronic recoils and nuclear recoils are explained using the scintillation quenching mechanism due to the variation of the average energy expended per electron hole pair, W value, which includes the energy lost to scintillation and phonon generation. We show the theoretical calculation of scintillation efficiency with W value in comparison with experimental data. The impact of variation of W value on the analysis of energy scale is discussed in detail. We conclude that the W value determined with experimental data depends on recoil energy and particle type. This work is supported by NSF in part by the NSF OIA 1434142, DOE Grant DE-FG02-10ER46709, and the State of South Dakota.

  13. A new liquid chromatography method with charge aerosol detector (CAD) for the determination of phospholipid classes. Application to milk phospholipids.

    PubMed

    Kiełbowicz, Grzegorz; Micek, Piotr; Wawrzeńczyk, Czesław

    2013-02-15

    A new rapid method for the quantitative analysis of five classes of phospholipids (PLs) (phosphatidylcholine--PC, lysophosphatidylcholine--LPC, phosphatidylethanolamine--PE and phosphatidylserine--PS and phosphatidylinositol--PI) using liquid chromatography with charge aerosol detector (CAD) is described. The separation of the compounds of interest was achieved on a diol stationary phase with a mobile phase consisting of 13% HCOOH, hexane and 2-propanol in 19 min elution program, including 10 min equilibration of the column. The method was applied to characterize the phospholipid fractions of cow milk. PLs present in cow milk were separated by solid-phase extraction (SPE) procedure with Si cartridges before LC analysis with recovery ranging from 95.3% to 104.4%. The use of CAD detection of the eluted compounds was precise, linear and sensitive.

  14. [Determination of fluorescent whitening agents in plastic food contact materials by high performance liquid chromatography with fluorescence detector].

    PubMed

    Jiao, Yanna; Ding, Li; Zhu, Shaohua; Fu, Shanliang; Gong, Qiang; Li, Hui; Wang, Libing

    2013-01-01

    A method for the determination of fluorescent whitening agents in plastic food contact materials by high performance liquid chromatography (HPLC) with fluorescence detector was developed. The samples were extracted with trichloromethane by sonication for 30 min at 40 degrees C. The HPLC method was performed on a column of Eclipse XDB-C18 (250 mm x 4.6 mm, 5 microm) by gradient elution using 5 mmol/L ammonium acetate and acetonitrile as the mobile phases, and detected by the fluorescence detector at an excitation wavelength of 350 nm and an emission wavelength of 430 nm. The experimental results indicated that the four fluorescent whitening agents were separated well. The limits of detection (LOD) (S/N = 3) were 0.3, 0.1, 0.05, 0.14 mg/L, and the limits of quantification (LOQ) (S/N = 10) were 1.0, 0.4, 0.2, 0.5 mg/L for 1,4-bis (4-cyanostyryl) benzene (C. I. 199), 1,4-bis (2-benzoxazolyl) naphthalene (C. I. 367), 4,4'-bis(2-methoxystyryl) biphenyl (C. I. 378) and 2,5-thiophenediylbis (5-tert-butyl-1,3-benzoxazole) (C. I. 184), respectively. Good linearities with correlation coefficients (r2) not less than 0.991 were obtained. The proposed method is simple, accurate, sensitive and can meet the requirements of the routine determination of fluorescent whitening agents in entry-exit products.

  15. Screening method for the determination of tetracyclines and fluoroquinolones in animal drinking water by liquid chromatography with diode array detector.

    PubMed

    Patyra, E; Kowalczyk, E; Grelik, A; Przeniosło-Siwczyńska, M; Kwiatek, K

    2015-01-01

    A liquid chromatography - diode array detector (HPLC-DAD) procedure has been developed for the determination of oxytetracycline (OTC), tetracycline (TC), chlorotetracycline (CTC), doxycycline (DC), enrofloxacin (ENR), ciprofloxacin (CIP), sarafloxacin (SAR) and flumequine (FLU) residues in animal drinking water. This method was applied to animal drinking water. Solid-phase extraction (SPE) clean-up on an Oasis HLB cartridge allowed an extract suitable for liquid chromatographic analysis to be obtained. Chromatographic separation was carried out on a C18 analytical column, using gradient elution with 0.1% trifluoroacetic acid - acetonitrile - methanol at 30°C. The flow-rate was 0.7 mL/min and the eluate was analysed at 330 nm. The whole procedure was evaluated according to the requirements of the Commission Decision 2002/657/EC, determining specificity, decision limit (CCα), detection capacity (CCβ), limit of detection (LOD), limit of quantification (LOQ), precision and accuracy during validation of the method. The recoveries of TCs and FQs from spiked samples at the levels of 10, 100 and 1000 μg/L were higher than 82%. The developed method based on HPLC-DAD has been applied for the determination of four tetracyclines and four fluoroquinolones in animal drinking water samples.

  16. Determination of swainsonine in the endophytic Undifilum fungi by high-performance liquid chromatography with evaporative light-scattering detector.

    PubMed

    Yang, Guo-Dong; Gao, Rui; Wang, Yan; Li, Jin-Cheng; Hu, Yan-Chun; Kang, Dan-Ju; Li, Yan-Hong; Li, Hai-Li; Geng, Guo-Xia; Wang, Jian-Hua

    2012-07-01

    Endophytic Undifilum oxytropis found within toxic locoweeds (Astragalus and Oxytropis spp.) produces the indolizidine alkaloid swainsonine, which is responsible for locoism in grazing animals. The aim of the current study is to establish an easy and accurate method for the determination of swainsonine in the endophytic Undifilum fungi. High-performance liquid chromatography (HPLC) with evaporative light-scattering detector (ELSD) was used for the assay of swainsonine in this study for the first time. The HPLC conditions were Waters XBridge hydrophilic interaction liquid chromatography column using acetonitrile-5 mM ammonium acetate (1:1, vol/vol) containing 0.02% (vol/vol) aqueous ammonium hydroxide as mobile phase at a flow rate of 0.5 mL/min. ELSD conditions were optimized at nebulizer-gas flow rate of 25 psi and drift tube temperature of 55 °C. The method was validated to achieve the satisfactory precision and recovery, and the calibration range was 15.625-250 μg/mL. Application of the developed analytical procedure to determine swainsonine content in the endophytic Undifilum fungi samples ensured its suitability for the routine analysis of swainsonine.

  17. Homestake tracking spectrometer: a one-mile deep 1400-ton liquid-scintillation nucleon-decay detector

    SciTech Connect

    Cherry, M.L.; Davidson, I.; Lande, K.; Lee, C.K.; Marshall, E.; Steinberg, R.I.; Cleveland, B.; Davis, R. Jr.; Lowenstein, D.

    1982-01-01

    We describe a proposed nucleon decay detector able to demonstrate the existence of nucleon decay for lifetimes up to 5 x 10/sup 32/ yr. The proposed instrument is a self-vetoed completely-active 1400-ton liquid scintillation Tracking Spectrometer to be located in the Homestake Mine at a depth of 4200 mwe, where the cosmic ray muon flux is only 1100/m/sup 2//yr, more than 10/sup 7/ times lower than the flux at the earth's surface. Based on computer simulations and laboratory measurements, the Tracking Spectrometer will have a spatial resolution of +- 15 cm (0.32 radiation lengths); energy resolution of +- 4.2%; and time resolution of +-1.3 ns. Because liquid scintillator responds to total ionization energy, all neutrinoless nucleon decay modes will produce a sharp (+- 4.2%) total energy peak at approximately 938 MeV, thereby allowing clear separation of nucleon decay events from atmospheric neutrino and other backgrounds. The instrument will be about equally sensitive to most nucleon decay modes. It will be able to identify most of the likely decay modes (including n ..-->.. ..nu.. + K/sub s//sup 0/ as suggested by supersymmetric grand unified theories), as well as determine the charge of lepton secondaries and the polarization of secondary muons.

  18. Photoacoustic spectroscopy-based detector for measuring benzene and toluene concentration in gas and liquid samples

    NASA Astrophysics Data System (ADS)

    Hanyecz, Veronika; Mohácsi, Árpád; Puskás, Sándor; Vágó, Árpád; Szabó, Gábor

    2011-12-01

    Here we present a novel instrument for on-line, automatic measurement of benzene and toluene concentration in gas and liquid samples produced in the natural gas industry. Operation of the instrument is based on the collection of analytes on an adsorbent, separation using a chromatographic column and detection by near-infrared diode laser-based photoacoustic spectroscopy. Sample handling, measurement and data evaluation are carried out fully automatically, using an integrated, programmable electronic unit. The instrument was calibrated in the laboratory for natural gas, nitrogen and liquid glycol samples, and tested under field conditions at a natural gas dehydration unit of the MOL Hungarian Oil and Gas Company. Minimum detectable concentrations (3σm-1) were found to be 2.5 µg l-1 for benzene and 4 µg l-1 for toluene in gas samples, while 1.5 mg l-1 for benzene and 3 mg l-1 for toluene in liquid samples, which is suitable for measuring benzene and toluene concentration in natural gas and glycol samples occurring at natural gas dehydration plants.

  19. Appraisal of transport and deformation in shale reservoirs using natural noble gas tracers

    SciTech Connect

    Heath, Jason E.; Kuhlman, Kristopher L.; Robinson, David G.; Bauer, Stephen J.; Gardner, William Payton

    2015-09-01

    This report presents efforts to develop the use of in situ naturally-occurring noble gas tracers to evaluate transport mechanisms and deformation in shale hydrocarbon reservoirs. Noble gases are promising as shale reservoir diagnostic tools due to their sensitivity of transport to: shale pore structure; phase partitioning between groundwater, liquid, and gaseous hydrocarbons; and deformation from hydraulic fracturing. Approximately 1.5-year time-series of wellhead fluid samples were collected from two hydraulically-fractured wells. The noble gas compositions and isotopes suggest a strong signature of atmospheric contribution to the noble gases that mix with deep, old reservoir fluids. Complex mixing and transport of fracturing fluid and reservoir fluids occurs during production. Real-time laboratory measurements were performed on triaxially-deforming shale samples to link deformation behavior, transport, and gas tracer signatures. Finally, we present improved methods for production forecasts that borrow statistical strength from production data of nearby wells to reduce uncertainty in the forecasts.

  20. Quantification of maltol in Korean ginseng (Panax ginseng) products by high-performance liquid chromatography-diode array detector

    PubMed Central

    Jeong, Hyun Cheol; Hong, Hee-Do; Kim, Young-Chan; Rhee, Young Kyoung; Choi, Sang Yoon; Kim, Kyung-Tack; Kim, Sung Soo; Lee, Young-Chul; Cho, Chang-Won

    2015-01-01

    Background: Maltol, as a type of phenolic compounds, is produced by the browning reaction during the high-temperature treatment of ginseng. Thus, maltol can be used as a marker for the quality control of various ginseng products manufactured by high-temperature treatment including red ginseng. For the quantification of maltol in Korean ginseng products, an effective high-performance liquid chromatography-diode array detector (HPLC-DAD) method was developed. Materials and Methods: The HPLC-DAD method for maltol quantification coupled with a liquid-liquid extraction (LLE) method was developed and validated in terms of linearity, precision, and accuracy. An HPLC separation was performed on a C18 column. Results: The LLE methods and HPLC running conditions for maltol quantification were optimized. The calibration curve of the maltol exhibited good linearity (R2 = 1.00). The limit of detection value of maltol was 0.26 μg/mL, and the limit of quantification value was 0.79 μg/mL. The relative standard deviations (RSDs) of the data of the intra- and inter-day experiments were <1.27% and 0.61%, respectively. The results of the recovery test were 101.35–101.75% with an RSD value of 0.21–1.65%. The developed method was applied successfully to quantify the maltol in three ginseng products manufactured by different methods. Conclusion: The results of validation demonstrated that the proposed HPLC-DAD method was useful for the quantification of maltol in various ginseng products. PMID:26246746

  1. Noble Gas Tracing of Fluid Transport in Shale Reservoirs

    NASA Astrophysics Data System (ADS)

    Heath, J. E.; Gardner, W. P.; Kuhlman, K. L.; Robinson, D. G.; Bauer, S. J.

    2014-12-01

    We investigate fluid transport mechanisms in a shale reservoir using natural noble gas tracers. Noble gas tracing is promising due to sensitivity of transport to: pore structure and sizes; phase partitioning between groundwater and liquid and gaseous hydrocarbons; and deformation from hydraulic fracturing and creation of surface area. A time-series of over thirty wellhead fluid samples were collected from two hydraulically-fractured wells with different oil-to-gas ratios, along with production data (i.e., flowrate and pressure). Tracer and production data sets can be combined to infer production flow regimes, to estimate reservoir transport parameters, and to improve forecasts of production decline. Sandia National Laboratories is a multi-program laboratory managed and operated by Sandia Corporation, a wholly owned subsidiary of Lockheed Martin Corporation, for the U.S. Department of Energy's National Nuclear Security Administration under contract DE-AC04-94AL85000.

  2. Method for low temperature preparation of a noble metal alloy

    DOEpatents

    Even, Jr., William R.

    2002-01-01

    A method for producing fine, essentially contamination free, noble metal alloys is disclosed. The alloys comprise particles in a size range of 5 to 500 nm. The method comprises 1. A method for preparing a noble metal alloy at low temperature, the method comprising the steps of forming solution of organometallic compounds by dissolving the compounds into a quantity of a compatible solvent medium capable of solvating the organometallic, mixing a portion of each solution to provide a desired molarity ratio of ions in the mixed solution, adding a support material, rapidly quenching droplets of the mixed solution to initiate a solute-solvent phase separation as the solvent freezes, removing said liquid cryogen, collecting and freezing drying the frozen droplets to produce a dry powder, and finally reducing the powder to a metal by flowing dry hydrogen over the powder while warming the powder to a temperature of about 150.degree. C.

  3. Scintillation efficiency of liquid argon in low energy neutron-argon scattering

    NASA Astrophysics Data System (ADS)

    Creus, W.; Allkofer, Y.; Amsler, C.; Ferella, A. D.; Rochet, J.; Scotto-Lavina, L.; Walter, M.

    2015-08-01

    Experiments searching for weak interacting massive particles with noble gases such as liquid argon require very low detection thresholds for nuclear recoils. A determination of the scintillation efficiency is crucial to quantify the response of the detector at low energy. We report the results obtained with a small liquid argon cell using a monoenergetic neutron beam produced by a deuterium-deuterium fusion source. The light yield relative to electrons was measured for six argon recoil energies between 11 and 120 keV at zero electric drift field.

  4. Verification of proton range, position, and intensity in IMPT with a 3D liquid scintillator detector system

    PubMed Central

    Archambault, L.; Poenisch, F.; Sahoo, N.; Robertson, D.; Lee, A.; Gillin, M. T.; Mohan, R.; Beddar, S.

    2012-01-01

    Purpose: Intensity-modulated proton therapy (IMPT) using spot scanned proton beams relies on the delivery of a large number of beamlets to shape the dose distribution in a highly conformal manner. The authors have developed a 3D system based on liquid scintillator to measure the spatial location, intensity, and depth of penetration (energy) of the proton beamlets in near real-time. Methods: The detector system consists of a 20 × 20 × 20 cc liquid scintillator (LS) material in a light tight enclosure connected to a CCD camera. This camera has a field of view of 25.7 by 19.3 cm and a pixel size of 0.4 mm. While the LS is irradiated, the camera continuously acquires images of the light distribution produced inside the LS. Irradiations were made with proton pencil beams produced with a spot-scanning nozzle. Pencil beams with nominal ranges in water between 9.5 and 17.6 cm were scanned to irradiate an area of 10 × 10 cm square on the surface of the LS phantom. Image frames were acquired at 50 ms per frame. Results: The signal to noise ratio of a typical Bragg peak was about 170. Proton range measured from the light distribution produced in the LS was accurate to within 0.3 mm on average. The largest deviation seen between the nominal and measured range was 0.6 mm. Lateral position of the measured pencil beam was accurate to within 0.4 mm on average. The largest deviation seen between the nominal and measured lateral position was 0.8 mm; however, the accuracy of this measurement could be improved by correcting light scattering artifacts. Intensity of single proton spots were measured with precision ranging from 3 % for the smallest spot intensity (0.005 MU) to 0.5 % for the largest spot (0.04 MU). Conclusions: Our LS detector system has been shown to be capable of fast, submillimeter spatial localization of proton spots delivered in a 3D volume. This system could be used for beam range, intensity and position verification in IMPT. PMID:22380355

  5. Screen-printed electrode based electrochemical detector coupled with ionic liquid dispersive liquid-liquid microextraction and microvolume back-extraction for determination of mercury in water samples.

    PubMed

    Fernández, Elena; Vidal, Lorena; Martín-Yerga, Daniel; Blanco, María del Carmen; Canals, Antonio; Costa-García, Agustín

    2015-04-01

    A novel approach is presented, whereby gold nanostructured screen-printed carbon electrodes (SPCnAuEs) are combined with in-situ ionic liquid formation dispersive liquid-liquid microextraction (in-situ IL-DLLME) and microvolume back-extraction for the determination of mercury in water samples. In-situ IL-DLLME is based on a simple metathesis reaction between a water-miscible IL and a salt to form a water-immiscible IL into sample solution. Mercury complex with ammonium pyrrolidinedithiocarbamate is extracted from sample solution into the water-immiscible IL formed in-situ. Then, an ultrasound-assisted procedure is employed to back-extract the mercury into 10 µL of a 4 M HCl aqueous solution, which is finally analyzed using SPCnAuEs. Sample preparation methodology was optimized using a multivariate optimization strategy. Under optimized conditions, a linear range between 0.5 and 10 µg L(-1) was obtained with a correlation coefficient of 0.997 for six calibration points. The limit of detection obtained was 0.2 µg L(-1), which is lower than the threshold value established by the Environmental Protection Agency and European Union (i.e., 2 µg L(-1) and 1 µg L(-1), respectively). The repeatability of the proposed method was evaluated at two different spiking levels (3 and 10 µg L(-1)) and a coefficient of variation of 13% was obtained in both cases. The performance of the proposed methodology was evaluated in real-world water samples including tap water, bottled water, river water and industrial wastewater. Relative recoveries between 95% and 108% were obtained.

  6. A novel liquid chromatography method using diode-array detector for the determination of oleuropein in dietary supplements.

    PubMed

    Bertolini, Tiziana; Vicentini, Lorenza; Boschetti, Silvia; Andreatta, Paolo; Gatti, Rita

    2016-09-10

    A simple and fast chromatographic method using ultraviolet diode-array detector (UV-DAD) was developed for the automatic high performance liquid chromatography (HPLC) determination of the title of oleuropein in a new dietary supplements in form of effervescent granules. The chromatographic separations were performed on a C18 core-shell column with detection at λ=232nm. The mobile phase consisted of deionized water with 0.1% TFA and acetonitrile under gradient conditions at a flow-rate of 0.8mL/min. Oleuropein and oleuroside present in the raw material were characterized by high performance liquid chromatography-electrospray ionization tandem mass spectrometry (HPLC-ESI-MS/MS). The validation of the analytical procedure has been performed determining the following parameters: specificity, linearity, repeatability, reproducibility, accuracy, limit of quantification (LOQ), stability of the standard and sample solutions. Linear response was observed in fortified placebo solutions (determination coefficient: 0.9998). Intra-day precision (relative standard deviation, RSD) was ≤5.0% for peak area and for retention times (tR) without significant differences between intra- and inter-day data. The limits of quantitation (LOQ) was about 5μg/mL and 9pmol/inject. Oleuropein recovery studies gave good results (99.9%) with a R.S.D. of 0.5%. The speed of analysis and the stability of the solutions with a fluctuation Δ (%) ≤2.0 at room temperature means an undoubted advantage of the method allowing the simultaneous preparation of many samples and consecutive chromatographic analyses by using an autosampler. The developed method is suitable for the quality control of oleuropein in raw material and industrial products. The method can be applied in any analytical laboratory not requiring a sophisticated instrumentation.

  7. A charged aerosol detector/chemiluminescent nitrogen detector/liquid chromatography/mass spectrometry system for regular and fragment compound analysis in drug discovery.

    PubMed

    Jiang, Yutao; Hascall, Daniel; Li, Delia; Pease, Joseph H

    2015-09-11

    In this paper, we introduce a high throughput LCMS/UV/CAD/CLND system that improves upon previously reported systems by increasing both the quantitation accuracy and the range of compounds amenable to testing, in particular, low molecular weight "fragment" compounds. This system consists of a charged aerosol detector (CAD) and chemiluminescent nitrogen detector (CLND) added to a LCMS/UV system. Our results show that the addition of CAD and CLND to LCMS/UV is more reliable for concentration determination for a wider range of compounds than either detector alone. Our setup also allows for the parallel analysis of each sample by all four detectors and so does not significantly increase run time per sample.

  8. WLS R&D for the detection of noble gas scintillation at LBL: seeing the light from neutrinos, to dark matter, to double beta decay

    NASA Astrophysics Data System (ADS)

    Gehman, V. M.

    2013-09-01

    Radiation detectors with noble gasses as the active medium are becoming increasingly common in experimental programs searching for physics beyond the standard model. Nearly all of these experiments rely to some degree on collecting scintillation light from noble gasses. The VUV wavelengths associated with noble gas scintillation mean that most of these experiments use a fluorescent material to shift the direct scintillation light into the visible or near UV band. We present an overview of the R&D program at LBL related to noble gas detectors for neutrino physics, double beta decay, and dark matter. This program ranges from precise measurements of the fluorescence behavior of wavelength shifting films, to the prototyping of large are VUV sensitive light guides for multi-kiloton detectors.

  9. A Bubble Chamber Revival: Superheated Liquid Detectors for Dark Matter Searches and Other Applications

    NASA Astrophysics Data System (ADS)

    Sonnenschein, Andrew

    2012-10-01

    Bubble chambers were recently deemed to be obsolete, of interest only to historians, but a few new applications have unexpectedly emerged in nuclear and particle astrophysics. These include the search for WIMP dark matter and the measurement of a few otherwise intractable nuclear cross sections. The new bubble chambers exploit features of the bubble nucleation process that were unappreciated or irrelevant in the 1950s-1970s when the technology was known for its capability to provide fine-grained tracking of high energy particles in a dense target medium. By carefully tuning the temperature and pressure, a liquid can be made selectively sensitive to particles on the basis of their specific rate of energy loss, enabling a high degree of background rejection power when searching for rare heavily-ionizing tracks. Surprisingly, additional information on the microstructure of particle tracks can be extracted from the acoustic noise produce by bubble nucleation. Other novel features of the new bubble chambers include the use of digital photography, self-triggering, and the achievement of nearly continuous sensitivity by the avoidance of bubble nucleation on internal wetted surfaces.

  10. Experimental Study on Cooling Performance of a Coaxial Pulse Tube Cryocooler for a Liquid Xenon Detector

    NASA Astrophysics Data System (ADS)

    Haruyama, T.; Kasami, K.; Nishitani, T.

    2010-04-01

    An experimental study to improve the cooling power of a coaxial pulse tube cryocooler (PTC) has been carried out. The operating temperature was optimized for cooling liquid xenon at around 165-170 K. The PTC has a coaxial configuration with a cylindrical regenerator inside, a hollow-walled cylindrical pulse tube. The cooling performance obtained was ˜180-200 W at around 165 K, when operated with a 6-6.5 kW GM-type compressor. For the phase shift between pressure and flow, a simple-orifice scheme was used, which resulted in stable operation of a long-term physics experiment. PTCs have now been successfully applied in physics experiments such as MEG and XENON for many years. In order to study flow disturbance inside of a tube, thermometers were placed on an outer cylinder wall to monitor gas temperature inside of a tube. In the original scheme, there is a single gas exhaust line from the pulse tube to an orifice valve and buffer tank. In this study, an additional exhaust line was used to suppress the flow disturbance in such a pulse tube. Also, the cooling power dependence on the regenerator was experimentally studied by changing the mesh size and the length of the regenerator.

  11. Noble Gas Temperature Proxy for Climate Change

    EPA Science Inventory

    Noble gases in groundwater appear to offer a practical approach for quantitatively determining past surface air temperatures over recharge areas for any watershed. The noble gas temperature (NGT) proxy should then permit a paleothermometry of a region over time. This terrestria...

  12. First Tests of a New Fast Waveform Digitizer for PMT Signal Read-out from Liquid Argon Dark Matter Detectors

    NASA Astrophysics Data System (ADS)

    Szelc, A. M.; Canci, N.; Cavanna, F.; Cortopassi, A.; D'Incecco, M.; Mini, G.; Pietropaolo, F.; Romboli, A.; Segreto, E.; Acciarri, R.

    A new generation Waveform Digitizer board as been recently made available on the market by CAEN. The new board CAEN V1751 with 8 Channels per board, 10 bit, 1 GS/s Flash ADC Waveform Digitizer (or 4 channel, 10 bit, 2 GS/s Flash ADC Waveform Digitizer -Dual Edge Sampling mode) with threshold and Auto-Trigger capabilities provides an ideal (relatively low-cost) solution for reading signals from liquid Argon detectors for Dark Matter search equipped with an array of PMTs for the detection of scintillation light. The board was extensively used in real experimental conditions to test its usefulness for possible future uses and to compare it with a state of the art digital oscilloscope. As results, PMT Signal sampling at 1 or 2 GS/s is appropriate for the reconstruction of the fast component of the signal scintillation in Argon (characteristic time of about 4 ns) and the extended dynamic range, after a small customization, allows for the detection of signals in the range of energy needed. The bandwidth is found to be adequate and the intrinsic noise is very low.

  13. Fingerprint Analysis of Desmodium Triquetrum L. Based on Ultra Performance Liquid Chromatography with Photodiode Array Detector Combined with Chemometrics Methods.

    PubMed

    Zhang, Meiling; Zhao, Cui; Liang, Xianrui; Ying, Yin; Han, Bing; Yang, Bo; Jiang, Cheng

    2016-01-01

    A fingerprinting approach was developed by means of ultra high-performance liquid chromatography with photodiode array detector for the quality control of Desmodium triquetrum L., an herbal medicine widely used for clinical purposes. Ten batches of raw material samples of D. triquetrum were collected from different regions of China. All UPLC analyses were carried out on a Waters ACQUITY UPLC BEH shield RP18 column (2.1 × 50 mm, 1.7 µm particle size) at 60°C, with a gradient mobile phase composed of 0.1% aqueous formic acid and acetonitrile at a flow rate of 0.45 mL/min. The method validation results demonstrated the developed method possessing desirable reproducibility, efficiency, and allowing fingerprint analysis in one chromatographic run within 13 min. The quality assessment was achieved by using chemometrics methods including similarity analysis, hierarchical clustering analysis and principal component analysis. The developed method can be used for further quality control of D. triquetrum.

  14. Magnetic field detector consisting of magnetic and semiconducting nanoparticles co-assembled in a liquid crystalline matrix

    NASA Astrophysics Data System (ADS)

    Amaral, Jose; Rodarte, Andrea; Wan, Jacky; Ferri, Christopher; Quint, Makiko; Pandolfi, Ron; Scheibner, Michael; Hirst, Linda; Ghosh, Sayantani

    2015-03-01

    An exciting area of research is using nano-constituents to create artificial materials that are multifunctional and allow for modification post-fabrication and in situ. We are investigating the ensemble behavior of iron-oxide magnetic nanoparticles (MNPs) and CdSe/ZnS quantum dots (QDs) when dispersed in an electro-optically active liquid crystalline (LC) matrix. The directed assembly of NPs in the matrix is driven by the temperature-induced transition of the LC from the isotropic to the nematic phase as the NPs are mostly expelled into the isotropic regions, finally ending up clustered around LC defect points when the transition is complete. Our results show a two-fold intensity increase of QD photoluminescence intensity with low magnetic fields (less than 100 mT). We speculate this increase is due to MNP rearrangement which produces a compaction of the clusters, resulting in the detection of increased QD emission. The individual components work together to act as a magnetic field detector and since they are direct assembled in a LC medium, they could potentially be used in a wide range of fluid-based applications. This work was funded by NSF grants DMR-1056860 and ECC-1227034. This work was funded by NSF Grants DMR-1056860 and ECC-1227034.

  15. The Noble-Abel Stiffened-Gas equation of state

    NASA Astrophysics Data System (ADS)

    Le Métayer, Olivier; Saurel, Richard

    2016-04-01

    Hyperbolic two-phase flow models have shown excellent ability for the resolution of a wide range of applications ranging from interfacial flows to fluid mixtures with several velocities. These models account for waves propagation (acoustic and convective) and consist in hyperbolic systems of partial differential equations. In this context, each phase is compressible and needs an appropriate convex equation of state (EOS). The EOS must be simple enough for intensive computations as well as boundary conditions treatment. It must also be accurate, this being challenging with respect to simplicity. In the present approach, each fluid is governed by a novel EOS named "Noble Abel stiffened gas," this formulation being a significant improvement of the popular "Stiffened Gas (SG)" EOS. It is a combination of the so-called "Noble-Abel" and "stiffened gas" equations of state that adds repulsive effects to the SG formulation. The determination of the various thermodynamic functions and associated coefficients is the aim of this article. We first use thermodynamic considerations to determine the different state functions such as the specific internal energy, enthalpy, and entropy. Then we propose to determine the associated coefficients for a liquid in the presence of its vapor. The EOS parameters are determined from experimental saturation curves. Some examples of liquid-vapor fluids are examined and associated parameters are computed with the help of the present method. Comparisons between analytical and experimental saturation curves show very good agreement for wide ranges of temperature for both liquid and vapor.

  16. A Dose Distribution Study of Uranyl Nitrate in Zebrafish using Liquid Scintillation and Passivated Implanted Planar Silicon Detectors

    NASA Astrophysics Data System (ADS)

    Alshammari, Ohud Fhaid

    Standard curves for a Perkin Elmer TriCarb 2800 liquid scintillation detector (LSC) and a Ludlum 3030p Passivated Implanted Planar Silicon detector have been developed and utilized for studying the dose distribution of depleted uranium (DU) within zebrafish. The DU source was crystallized uranyl nitrate (N2O8U•6H2O) solution, normally used for staining in electron microscopy with a manufactured average specific activity of 0.3 uCi/g. Zebrafish, both larvae and adults, were exposed to three different mass concentrations, dissected, dissolved and counted using an LSC. The counts were compared to the standard curve correlating the measured activity to that of the mass absorbed. It was found that the larvae were more tolerant to the toxicity of the DU by almost a factor of 10 showing survival up to 200 ppm where the adults had zero survival when exposed to concentrations above 20 ppm. The absorbed DU was observed to concentrate more heavily in the skeletal structure and the blood containing organs (liver and heart) when comparing the relative mass concentrations observed in each organ compared to that of the whole fish exposed to the same concentration. The highest absorbed dose rate was found in the skeletal system at 3.5 mGy/d followed by the blood containing organs at 2.2 mGy/d when exposed to 20 ppm DU. It was also noted that the bioconcentration factors (BCF) of the adult zebrafish followed the same trend observed in similar studies. As the mass concentration of DU was lowered, the BCF calculated for fish exposed increased with a BCF of 130.6 found for those exposed to 20 ppm U and a BCF of 774.2 for fish exposed to 2 ppm. This method shows to present a suitable way of developing a dose distribution for DU along with similar isotopes which will be instrumental in studying the long term effects of more specific exposures to natural radioactive metals combined with other common environmental exposures.

  17. Platinum-coated non-noble metal-noble metal core-shell electrocatalysts

    DOEpatents

    Adzic, Radoslav; Zhang, Junliang; Mo, Yibo; Vukmirovic, Miomir

    2015-04-14

    Core-shell particles encapsulated by a thin film of a catalytically active metal are described. The particles are preferably nanoparticles comprising a non-noble core with a noble metal shell which preferably do not include Pt. The non-noble metal-noble metal core-shell nanoparticles are encapsulated by a catalytically active metal which is preferably Pt. The core-shell nanoparticles are preferably formed by prolonged elevated-temperature annealing of nanoparticle alloys in an inert environment. This causes the noble metal component to surface segregate and form an atomically thin shell. The Pt overlayer is formed by a process involving the underpotential deposition of a monolayer of a non-noble metal followed by immersion in a solution comprising a Pt salt. A thin Pt layer forms via the galvanic displacement of non-noble surface atoms by more noble Pt atoms in the salt. The overall process is a robust and cost-efficient method for forming Pt-coated non-noble metal-noble metal core-shell nanoparticles.

  18. Neutrino Detectors: Challenges and Opportunities

    SciTech Connect

    Soler, F. J. P.

    2011-10-06

    This paper covers possible detector options suitable at future neutrino facilities, such as Neutrino Factories, Super Beams and Beta Beams. The Magnetised Iron Neutrino Detector (MIND), which is the baseline detector at a Neutrino Factory, will be described and a new analysis which improves the efficiency of this detector at low energies will be shown. Other detectors covered include the Totally Active Scintillating Detectors (TASD), particularly relevant for a low energy Neutrino Factory, emulsion detectors for tau detection, liquid argon detectors and megaton scale water Cherenkov detectors. Finally the requirements of near detectors for long-baseline neutrino experiments will be demonstrated.

  19. High-resolution liquid- and solid-state nuclear magnetic resonance of nanoliter sample volumes using microcoil detectors.

    PubMed

    Kentgens, A P M; Bart, J; van Bentum, P J M; Brinkmann, A; van Eck, E R H; Gardeniers, J G E; Janssen, J W G; Knijn, P; Vasa, S; Verkuijlen, M H W

    2008-02-07

    The predominant means to detect nuclear magnetic resonance (NMR) is to monitor the voltage induced in a radiofrequency coil by the precessing magnetization. To address the sensitivity of NMR for mass-limited samples it is worthwhile to miniaturize this detector coil. Although making smaller coils seems a trivial step, the challenges in the design of microcoil probeheads are to get the highest possible sensitivity while maintaining high resolution and keeping the versatility to apply all known NMR experiments. This means that the coils have to be optimized for a given sample geometry, circuit losses should be avoided, susceptibility broadening due to probe materials has to be minimized, and finally the B(1)-fields generated by the rf coils should be homogeneous over the sample volume. This contribution compares three designs that have been miniaturized for NMR detection: solenoid coils, flat helical coils, and the novel stripline and microslot designs. So far most emphasis in microcoil research was in liquid-state NMR. This contribution gives an overview of the state of the art of microcoil solid-state NMR by reviewing literature data and showing the latest results in the development of static and micro magic angle spinning (microMAS) solenoid-based probeheads. Besides their mass sensitivity, microcoils can also generate tremendously high rf fields which are very useful in various solid-state NMR experiments. The benefits of the stripline geometry for studying thin films are shown. This geometry also proves to be a superior solution for microfluidic NMR implementations in terms of sensitivity and resolution.

  20. High-resolution liquid- and solid-state nuclear magnetic resonance of nanoliter sample volumes using microcoil detectors

    NASA Astrophysics Data System (ADS)

    Kentgens, A. P. M.; Bart, J.; van Bentum, P. J. M.; Brinkmann, A.; van Eck, E. R. H.; Gardeniers, J. G. E.; Janssen, J. W. G.; Knijn, P.; Vasa, S.; Verkuijlen, M. H. W.

    2008-02-01

    The predominant means to detect nuclear magnetic resonance (NMR) is to monitor the voltage induced in a radiofrequency coil by the precessing magnetization. To address the sensitivity of NMR for mass-limited samples it is worthwhile to miniaturize this detector coil. Although making smaller coils seems a trivial step, the challenges in the design of microcoil probeheads are to get the highest possible sensitivity while maintaining high resolution and keeping the versatility to apply all known NMR experiments. This means that the coils have to be optimized for a given sample geometry, circuit losses should be avoided, susceptibility broadening due to probe materials has to be minimized, and finally the B1-fields generated by the rf coils should be homogeneous over the sample volume. This contribution compares three designs that have been miniaturized for NMR detection: solenoid coils, flat helical coils, and the novel stripline and microslot designs. So far most emphasis in microcoil research was in liquid-state NMR. This contribution gives an overview of the state of the art of microcoil solid-state NMR by reviewing literature data and showing the latest results in the development of static and micro magic angle spinning (microMAS) solenoid-based probeheads. Besides their mass sensitivity, microcoils can also generate tremendously high rf fields which are very useful in various solid-state NMR experiments. The benefits of the stripline geometry for studying thin films are shown. This geometry also proves to be a superior solution for microfluidic NMR implementations in terms of sensitivity and resolution.

  1. Incorporation of noble metals into aerogels

    DOEpatents

    Hair, L.M.; Sanner, R.D.; Coronado, P.R.

    1998-12-22

    Aerogels or xerogels containing atomically dispersed noble metals for applications such as environmental remediation are disclosed. New noble metal precursors, such as Pt--Si or Pd(Si--P){sub 2}, have been created to bridge the incompatibility between noble metals and oxygen, followed by their incorporation into the aerogel or xerogel through sol-gel chemistry and processing. Applications include oxidation of hydrocarbons and reduction of nitrogen oxide species, complete oxidation of volatile organic carbon species, oxidative membranes for photocatalysis and partial oxidation for synthetic applications.

  2. Incorporation of noble metals into aerogels

    DOEpatents

    Hair, Lucy M.; Sanner, Robert D.; Coronado, Paul R.

    1998-01-01

    Aerogels or xerogels containing atomically dispersed noble metals for applications such environmental remediation. New noble metal precursors, such as Pt--Si or Pd(Si--P).sub.2, have been created to bridge the incompatibility between noble metals and oxygen, followed by their incorporation into the aerogel or xerogel through sol-gel chemistry and processing. Applications include oxidation of hydrocarbons and reduction of nitrogen oxide species, complete oxidation of volatile organic carbon species, oxidative membranes for photocatalysis and partial oxidation for synthetic applications.

  3. Recovery and use of fission product noble metals

    SciTech Connect

    Jensen, G.A.; Rohmann, C.A.; Perrigo, L.D.

    1980-06-01

    Noble metals in fission products are of strategic value. Market prices for noble metals are rising more rapidly than recovery costs. A promising concept has been developed for recovery of noble metals from fission product waste. Although the assessment was made only for the three noble metal fission products (Rh, Pd, Ru), there are other fission products and actinides which have potential value. (DLC)

  4. 21 CFR 872.3060 - Noble metal alloy.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Noble metal alloy. 872.3060 Section 872.3060 Food... DEVICES DENTAL DEVICES Prosthetic Devices § 872.3060 Noble metal alloy. (a) Identification. A noble metal alloy is a device composed primarily of noble metals, such as gold, palladium, platinum, or silver,...

  5. 21 CFR 872.3060 - Noble metal alloy.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Noble metal alloy. 872.3060 Section 872.3060 Food... DEVICES DENTAL DEVICES Prosthetic Devices § 872.3060 Noble metal alloy. (a) Identification. A noble metal alloy is a device composed primarily of noble metals, such as gold, palladium, platinum, or silver,...

  6. 21 CFR 872.3060 - Noble metal alloy.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Noble metal alloy. 872.3060 Section 872.3060 Food... DEVICES DENTAL DEVICES Prosthetic Devices § 872.3060 Noble metal alloy. (a) Identification. A noble metal alloy is a device composed primarily of noble metals, such as gold, palladium, platinum, or silver,...

  7. 21 CFR 872.3060 - Noble metal alloy.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Noble metal alloy. 872.3060 Section 872.3060 Food... DEVICES DENTAL DEVICES Prosthetic Devices § 872.3060 Noble metal alloy. (a) Identification. A noble metal alloy is a device composed primarily of noble metals, such as gold, palladium, platinum, or silver,...

  8. 21 CFR 872.3060 - Noble metal alloy.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Noble metal alloy. 872.3060 Section 872.3060 Food... DEVICES DENTAL DEVICES Prosthetic Devices § 872.3060 Noble metal alloy. (a) Identification. A noble metal alloy is a device composed primarily of noble metals, such as gold, palladium, platinum, or silver,...

  9. Solubility of noble gases in serpentine - Implications for meteoritic noble gas abundances

    NASA Technical Reports Server (NTRS)

    Zaikowski, A.; Schaeffer, O. A.

    1979-01-01

    An investigation of the solubilities of the noble gases from synthesis and solubility studies of the sheet silicate mineral serpentine in carbonaceous chondrites is presented. Hydrothermal synthesis and exchange experiments were made at 340C and 1 kbar with noble gas partial pressures from 2 times 10 to the -8th power to 0.1 atm. The measured distribution coefficients for noble gases are not sufficiently high to account for the trapped noble gases in carbonaceous chondrites by exchange in solar nebula if meteoritic minerals have comparable distribution coefficients. Also, serpentine gains and loses noble gases to approach equilibrium values with the terrestrial atmosphere, indicating that this exposure may have influenced the noble gas abundances in phyllosilicate minerals of these chondrites. The dispersion of K-Ar ages of carbonaceous chondrites could be the result of phyllosilicates approaching equilibrium solubility of atmospheric Ar-40.

  10. Noble metal superparticles and methods of preparation thereof

    DOEpatents

    Sun, Yugang; Hu, Yongxing

    2016-07-12

    A method comprises heating an aqueous solution of colloidal silver particles. A soluble noble metal halide salt is added to the aqueous solution which undergoes a redox reaction on a surface of the silver particles to form noble metal/silver halide SPs, noble metal halide/silver halide SPs or noble metal oxide/silver halide SPs on the surface of the silver particles. The heat is maintained for a predetermined time to consume the silver particles and release the noble metal/silver halide SPs, the noble metal halide/silver halide SPs or the noble metal oxide/silver halide SPs into the aqueous solution. The aqueous solution is cooled. The noble metal/silver halide SPs, the noble metal halide/silver halide SPs or noble metal oxide/silver halide SPs are separated from the aqueous solution. The method optionally includes adding a soluble halide salt to the aqueous solution.

  11. On a cryogenic noble gas ion catcher

    NASA Astrophysics Data System (ADS)

    Dendooven, P.; Purushothaman, S.; Gloos, K.

    2006-03-01

    In situ purification of the gas used as stopping medium in a noble gas ion catcher by operating the device at low temperatures of 60-150 K was investigated. Alpha-decay recoil ions from a 223Ra source served as energetic probes. The combined ion survival and transport efficiencies for 219Rn ions saturated below about 90 K, reaching 28.7(17)% in helium, 22.1(13)% in neon, and 17.0(10)% in argon. These values may well reflect the charge exchange and stripping cross-sections during the slowing down of the ions, and thus represent a fundamental upper limit for the efficiency of noble gas ion catcher devices. We suggest the cryogenic noble gas ion catcher as a technically simpler alternative to the ultra-high purity noble gas ion catcher operating at room temperature.

  12. Noble gas sputtering calculations using TRIM

    SciTech Connect

    Greene, J.P.; Nemanich, J.; Thomas, G.E.; Schiel, S.L.

    1996-12-31

    In conjunction with our experimental work on saddle field ion sputtering, we have attempted to apply the Monte Carlo program TRIM (Transport of Ions in Matter) to calculate the sputter yields for a variety of noble gas sputtering applications. Comparison with experiments are shown. Information extracted from these analyses have proved useful in optimizing the experimental sputtering parameters. Calculated sputter yields obtained utilizing TRIM are presented for noble gas sputtering of a variety of materials common to nuclear target production.

  13. Chemical composition of Titan's lakes and noble gases sequestration

    NASA Astrophysics Data System (ADS)

    Cordier, D.; Mousis, O.; Lunine, J.-I.; Lavvas, P.; Lobo, L.; Ferreira, A.

    2010-04-01

    Titan is one of the most enigmatic objects in the Solar System. The presence of hydrocarbon lakes and even a global ocean have been suspected for decades. The dark features discovered by the CASSINI spacecraft are good candidates for these expected lakes (see McEwen et al. 2005 and Stofan et al. 2007). Their chemical composition has still not been measured but numerical models can give relatively accurate predictions. In the present work, we use the recent model of Titan's lakes chemical composition elaborated by Cordier et al. (2009) in light of the recent Cassini-Huygens measurements in order to investigate the possibility of sequestration of large quantities of noble gases in these liquids. Indeed, the noble gas abundances have been found to be largely in subsolar abundances in the atmosphere of Titan and the origin of this impoverishment is still poorly understood. Our preliminary results show that, under specific circumstances, at least the atmospheric depletion in krypton could be caused by its dissolution in the Titan's surface hydrocarbon liquid phase.

  14. Design and First Results of the CoDeX Liquid-Xenon Compton-Imaging Detector

    NASA Astrophysics Data System (ADS)

    Tennyson, Brian; Cahn, Sidney; Bernard, Ethan; Boulton, Elizabeth; Destefano, Nicholas; Edwards, Blair; Hackenburg, Ariana; Horn, Markus; Larsen, Nicole; Nikkel, James; Wahl, Christopher; Gai, Moshe; McKinsey, Daniel

    2016-03-01

    CoDeX (Compton-imaging Detector in Xenon) is an R&D Compton gamma-ray imaging detector that uses 30 kg of xenon in a two-phase time projection chamber. Time projection relative to the initial scintillation signal provides the vertical interaction positions, and either PMT-sensed gas electroluminescence or a charge-sensitive amplifier quantifies the drifted ionization signal. Detector features to enable Compton imaging are a pair of instrumented wire grids added to sense the horizontal position of clouds of drifted electrons that traverse the detector. Each wire is individually amplified in the cold xenon environment. Design choices addressing the thermodynamic and xenon purity constraints of this system will be discussed. We will also discuss the mechanical designs, engineering challenges, and performance of this Compton-imaging detector.

  15. MO-F-CAMPUS-T-03: Verification of Range, SOBP Width, and Output for Passive-Scattering Proton Beams Using a Liquid Scintillator Detector

    SciTech Connect

    Henry, T; Robertson, D; Therriault-Proulx, F; Beddar, S

    2015-06-15

    Purpose: Liquid scintillators have been shown to provide fast and high-resolution measurements of radiation beams. However, their linear energy transfer-dependent response (quenching) limits their use in proton beams. The purpose of this study was to develop a simple and fast method to verify the range, spread-out Bragg peak (SOBP) width, and output of a passive-scattering proton beam with a liquid scintillator detector, without the need for quenching correction. Methods: The light signal from a 20×20×20 cm3 liquid scintillator tank was collected with a CCD camera. Reproducible landmarks on the SOBP depth-light curve were identified which possessed a linear relationship with the beam range and SOBP width. The depth-light profiles for three beam energies (140, 160 and 180 MeV) with six SOBP widths at each energy were measured with the detector. Beam range and SOBP width calibration factors were obtained by comparing the depth-light curve landmarks with the nominal range and SOBP width for each beam setting. The daily output stability of the liquid scintillator detector was also studied by making eight repeated output measurements in a cobalt-60 beam over the course of two weeks. Results: The mean difference between the measured and nominal beam ranges was 0.6 mm (σ=0.2 mm), with a maximum difference of 0.9 mm. The mean difference between the measured and nominal SOBP widths was 0.1 mm (σ=1.8 mm), with a maximum difference of 4.0 mm. Finally an output variation of 0.14% was observed for 8 measurements performed over 2 weeks. Conclusion: A method has been developed to determine the range and SOBP width of a passive-scattering proton beam in a liquid scintillator without the need for quenching correction. In addition to providing rapid and accurate beam range and SOBP measurements, the detector is capable of measuring the output consistency with a high degree of precision. This project was supported in part by award number CA182450 from the National Cancer

  16. CANCELLED Molecular dynamics simulations of noble gases in liquidwater: Solvati on structure, self-diffusion, and kinetic isotopeeffect

    SciTech Connect

    Bourg, I.C.; Sposito, G.

    2007-05-25

    Despite their great importance in low-temperaturegeochemistry, self-diffusion coefficients of noble gas isotopes in liquidwater (D) have been measured only for the major isotopes of helium, neon,krypton and xenon. Data on the self-diffusion coefficients of minor noblegas isotopes are essentially non-existent and so typically are estimatedby a kinetic theory model in which D varies as the inverse square root ofthe isotopic mass (m): D proportional to m-0.5. To examine the validityof the kinetic theory model, we performed molecular dynamics (MD)simulations of the diffusion of noble gases in ambient liquid water withan accurate set of noble gas-water interaction potentials. Our simulationresults agree with available experimental data on the solvation structureand self-diffusion coefficients of the major noble gas isotopes in liquidwater and reveal for the first time that the isotopic mass-dependence ofall noble gas self-diffusion coefficients has the power-law form Dproportional to m-beta with 0noble gasisotopes caused by diffusion in ambient liquid water.

  17. Electrogenerated chemiluminescence detector based on Ru(bpy)32+ immobilized in cation exchange resin for high-performance liquid chromatography: An approach to stable detection

    NASA Astrophysics Data System (ADS)

    Sun, Yonghua; Zhang, Zhujun; Zhang, Xinfeng

    2013-12-01

    In this work, an electrogenerated chemiluminescence (ECL) detector with improved stability was developed for high-performance liquid chromatography (HPLC) detection of hydrochlorothiazide (HCTZ). The detector was prepared by packing cation exchanged resin particles in a glass tube, followed by inserting Pt wires (working electrode) in this tube and sealing. The leakage of Ru(bpy)32+ from the resin was compensated by adding a small amount of Ru(bpy)32+ in the mobile phase. Factors affected the performance of the proposed ECL detector were investigated. Under the optimal conditions, the ECL intensity has a linear relationship with the concentration of HCTZ in the range of 5.0 × 10-8 g mL-1 - 2.5 × 10-5 g mL-1 and the detection limit was 2.0 × 10-8 g mL-1 (S/N = 3). Application of the detector to the analysis of HCTZ in human serum proved feasible.

  18. Electrogenerated chemiluminescence detector based on Ru(bpy)3(2+) immobilized in cation exchange resin for high-performance liquid chromatography: An approach to stable detection.

    PubMed

    Sun, Yonghua; Zhang, Zhujun; Zhang, Xinfeng

    2013-12-01

    In this work, an electrogenerated chemiluminescence (ECL) detector with improved stability was developed for high-performance liquid chromatography (HPLC) detection of hydrochlorothiazide (HCTZ). The detector was prepared by packing cation exchanged resin particles in a glass tube, followed by inserting Pt wires (working electrode) in this tube and sealing. The leakage of Ru(bpy)3(2+) from the resin was compensated by adding a small amount of Ru(bpy)3(2+) in the mobile phase. Factors affected the performance of the proposed ECL detector were investigated. Under the optimal conditions, the ECL intensity has a linear relationship with the concentration of HCTZ in the range of 5.0 × 10(-8) g mL(-1)-2.5 × 10(-5) g mL(-1) and the detection limit was 2.0 × 10(-8) g mL(-1) (S/N=3). Application of the detector to the analysis of HCTZ in human serum proved feasible.

  19. Determination of phenylephrine hydrochloride, chlorpheniramine maleate, and methscopolamine nitrate in tablets or capsules by liquid chromatography with two UV absorbance detectors in series.

    PubMed

    Cieri, Uco R

    2006-01-01

    A procedure is presented for the simultaneous determination of phenylephrine HCI (PE), chlorpheniramine maleate (CM), and methscopolamine nitrate in commercial tablets or capsules by liquid chromatography (LC) with 2 UV absorbance detectors in series. Reference and sample solutions are prepared in methanol. LC separations are performed on a 7.5 cm Novapak silica column. The mobile phase is prepared by mixing 930 mL methanol with 70 mL of a 0.5% aqueous solution of 1-pentanesulfonic acid, sodium salt. The injection volume is 20 microL; the flow rate is approximately 1 mL/min. Retention times are approximately 1.5 min for PE, 3 min for CM, and 6 min for methscopolamine nitrate. One detector determines the first 2 compounds at 265 nm, but the third compound does not produce a detectable peak. The other detector set at 210 nm generates peaks for all 3 compounds, but only methscopolamine is within the recorder range; the other 2 compounds are exceedingly off scale. If it is not feasible or desirable to arrange 2 UV absorbance detectors in series, separate determinations can be made, one for the first 2 compounds and the other for the third component of the mixture. Two commercial samples of tablets and 2 commercial samples of capsules were analyzed by the proposed method. Recovery studies were also conducted with amounts of the 3 compounds ranging from 80 to 120% of the quantities present in the sample solutions.

  20. Synthesis of noble metal nanoparticles

    NASA Astrophysics Data System (ADS)

    Bahadory, Mozhgan

    Improved methods were developed for the synthesis of noble metal nanoparticles. Laboratory experiments were designed for introducing of nanotechnology into the undergraduate curriculum. An optimal set of conditions for the synthesis of clear yellow colloidal silver was investigated. Silver nanoparticles were obtained by borohydride reduction of silver nitrate, a method which produces particles with average size of 12+/-2 nm, determined by Transmission Electron Microscopy (TEM). The plasmon absorbance is at 397 nm and the peak width at half maximum (PWHM) is 70-75 nm. The relationship between aggregation and optical properties was determined along with a method to protect the particles using polyvinylpyrrolidone (PVP). A laboratory experiment was designed in which students synthesize yellow colloidal silver, estimate particle size using visible spectroscopy, and study aggregation effects. The synthesis of the less stable copper nanoparticles is more difficult because copper nanopaticles are easily oxidized. Four methods were used for the synthesis of copper nanoparticles, including chemical reduction with sodium borohydride, sodium borohydride with potassium iodide, isopropyl alcohol with cetyltrimethylammonium bormide (CTAB) and reducing sugars. The latter method was also the basis for an undergraduate laboratory experiment. For each reaction, the dependence of stability of the copper nanoparticles on reagent concentrations, additives, relative amounts of reactants, and temperature is explored. Atomic force microscopy (AFM), TEM and UV-Visible Spectroscopy were used to characterize the copper nanoparticles. A laboratory experiment to produce copper nanoparticles from household chemicals was developed.

  1. Separating double-beta decay events from solar neutrino interactions in a kiloton-scale liquid scintillator detector by fast timing

    NASA Astrophysics Data System (ADS)

    Elagin, Andrey; Frisch, Henry J.; Naranjo, Brian; Ouellet, Jonathan; Winslow, Lindley; Wongjirad, Taritree

    2017-03-01

    We present a technique for separating nuclear double beta decay (ββ -decay) events from background neutrino interactions due to 8B decays in the sun. This background becomes dominant in a kiloton-scale liquid-scintillator detector deep underground and is usually considered as irreducible due to an overlap in deposited energy with the signal. However, electrons from 0 νββ -decay often exceed the Cherenkov threshold in liquid scintillator, producing photons that are prompt and correlated in direction with the initial electron direction. The use of large-area fast photodetectors allows some separation of these prompt photons from delayed isotropic scintillation light and, thus, the possibility of reconstructing the event topology. Using a simulation of a 6.5 m radius liquid scintillator detector with 100 ps resolution photodetectors, we show that a spherical harmonics analysis of early-arrival light can discriminate between 0 νββ -decay signal and 8B solar neutrino background events on a statistical basis. Good separation will require the development of a slow scintillator with a 5 ns risetime.

  2. Muon-induced background to proton decay in the p →K+ ν decay channel with large underground liquid argon TPC detectors

    NASA Astrophysics Data System (ADS)

    Klinger, J.; Kudryavtsev, V. A.; Richardson, M.; Spooner, N. J. C.

    2015-06-01

    Large liquid argon TPC detector programs such as LBNE and LAGUNA-LBNO will be able to make measurements of the proton lifetime which will outperform Cherenkov detectors in the proton decay channel p →K+ ν. At the large depths which are proposed for such experiments, a non-negligible source of isolated charged kaons may be produced in the showers of cosmogenic muons. We present an estimate of the cosmogenic muon background to proton decay in the p →K+ ν channel. The simulation of muon transport to a depth of 4 km w.e. is performed in the MUSIC framework and the subsequent propagation of muons and secondary particles in the vicinity of a cylindrical 20 kt LAr target is performed using GEANT4. An exposure time of 100 years is considered, with a rate of <0.0012 events/kt/year at 90% CL predicted from our simulations.

  3. Measurements of high energy neutrons penetrated through iron shields using the Self-TOF detector and an NE213 organic liquid scintillator

    NASA Astrophysics Data System (ADS)

    Sasaki, M.; Nakao, N.; Nunomiya, T.; Nakamura, T.; Fukumura, A.; Takada, M.

    2002-11-01

    Neutron energy spectra penetrated through iron shields were measured using the Self-TOF detector and an NE213 organic liquid scintillator which have been newly developed by our group at the Heavy-Ion Medical Accelerator in Chiba (HIMAC) of National Institute of Radiological Sciences (NIRS), Japan. Neutrons were generated by bombarding 400 MeV/nucleon C ion on a thick (stopping-length) copper target. The neutron spectra in the energy range from 20 to 800 MeV were obtained through the FORIST unfolding code with their response functions and compared with the MCNPX calculations combined with the LA150 cross section library. The neutron fluence measured by the NE213 detector was simulated by the track length estimator in the MCNPX, and evaluated the contribution of the room-scattered neutrons. The calculations are in fairly good agreement with the measurements. Neutron fluence attenuation lengths were obtained from the experimental results and the calculation.

  4. Noble gas fractionation during subsurface gas migration

    NASA Astrophysics Data System (ADS)

    Sathaye, Kiran J.; Larson, Toti E.; Hesse, Marc A.

    2016-09-01

    Environmental monitoring of shale gas production and geological carbon dioxide (CO2) storage requires identification of subsurface gas sources. Noble gases provide a powerful tool to distinguish different sources if the modifications of the gas composition during transport can be accounted for. Despite the recognition of compositional changes due to gas migration in the subsurface, the interpretation of geochemical data relies largely on zero-dimensional mixing and fractionation models. Here we present two-phase flow column experiments that demonstrate these changes. Water containing a dissolved noble gas is displaced by gas comprised of CO2 and argon. We observe a characteristic pattern of initial co-enrichment of noble gases from both phases in banks at the gas front, followed by a depletion of the dissolved noble gas. The enrichment of the co-injected noble gas is due to the dissolution of the more soluble major gas component, while the enrichment of the dissolved noble gas is due to stripping from the groundwater. These processes amount to chromatographic separations that occur during two-phase flow and can be predicted by the theory of gas injection. This theory provides a mechanistic basis for noble gas fractionation during gas migration and improves our ability to identify subsurface gas sources after post-genetic modification. Finally, we show that compositional changes due to two-phase flow can qualitatively explain the spatial compositional trends observed within the Bravo Dome natural CO2 reservoir and some regional compositional trends observed in drinking water wells overlying the Marcellus and Barnett shale regions. In both cases, only the migration of a gas with constant source composition is required, rather than multi-stage mixing and fractionation models previously proposed.

  5. ABOUT THE POSSIBLE ROLE OF HYDROCARBON LAKES IN THE ORIGIN OF TITAN'S NOBLE GAS ATMOSPHERIC DEPLETION

    SciTech Connect

    Cordier, D.; Mousis, O.; Lebonnois, S.; Lavvas, P.; Lobo, L. Q.; Ferreira, A. G. M.

    2010-10-01

    An unexpected feature of Titan's atmosphere is the strong depletion in primordial noble gases revealed by the Gas Chromatograph Mass Spectrometer aboard the Huygens probe during its descent on 2005 January 14. Although several plausible explanations have already been formulated, no definitive response to this issue has yet been found. Here, we investigate the possible sequestration of these noble gases in the liquid contained in lakes and wet terrains on Titan and the consequences for their atmospheric abundances. Considering the atmosphere and the liquid existing on the soil as a whole system, we compute the abundance of each noble gas relative to nitrogen. To do so, we make the assumption of thermodynamic equilibrium between the liquid and the atmosphere, the abundances of the different constituents being determined via regular solution theory. We find that xenon's atmospheric depletion can be explained by its dissolution at ambient temperature in the liquid presumably present on Titan's soil. In the cases of argon and krypton, we find that the fractions incorporated in the liquid are negligible, implying that an alternative mechanism must be invoked to explain their atmospheric depletion.

  6. Photodiode array to charged aerosol detector response ratio enables comprehensive quantitative monitoring of basic drugs in blood by ultra-high performance liquid chromatography.

    PubMed

    Viinamäki, Jenni; Ojanperä, Ilkka

    2015-03-20

    Quantitative screening for a broad range of drugs in blood is regularly required to assess drug abuse and poisoning within analytical toxicology. Mass spectrometry-based procedures suffer from the large amount of work required to maintain quantitative calibration in extensive multi-compound methods. In this study, a quantitative drug screening method for blood samples was developed based on ultra-high performance liquid chromatography with two consecutive detectors: a photodiode array detector and a corona charged aerosol detector (UHPLC-DAD-CAD). The 2.1 mm × 150 mm UHPLC column contained a high-strength silica C18 bonded phase material with a particle size of 1.8 μm, and the mobile phase consisted of methanol/0.1% trifluoroacetic acid in gradient mode. Identification was based on retention time, UV spectrum and the response ratio from the two detectors. Using historic calibration over a one-month period, the median precision (RSD) of retention times was 0.04% and the median accuracy (bias) of quantification 6.75%. The median precision of the detector response ratio over two orders of magnitude was 12%. The applicable linear ranges were generally 0.05-5 mg L(-1). The method was validated for 161 compounds, including antipsychotics, antidepressants, antihistamines, opioid analgesics, and adrenergic beta blocking drugs, among others. The main novelty of the method was the proven utility of the response ratio of DAD to CAD, which provided the additional identification efficiency required. Unlike with mass spectrometry, the high stability of identification and quantification allowed the use of facile historic calibration.

  7. Simultaneous extraction and analysis by high performance liquid chromatography coupled to diode array and mass spectrometric detectors of bixin and phenolic compounds from annatto seeds.

    PubMed

    Chisté, Renan Campos; Yamashita, Fábio; Gozzo, Fábio Cesar; Mercadante, Adriana Zerlotti

    2011-01-07

    This study was designed to identify and quantify the carotenoids and phenolic compounds from annatto seeds using high performance liquid chromatography coupled to diode array and mass spectrometer detectors (HPLC-DAD-MS/MS). Furthermore, using response surface methodology, an optimized procedure for simultaneous extraction of these compounds was established. In addition to bixin, known to be the main carotenoid in annatto seeds, hypolaetin and a caffeoyl acid derivative were identified as the main phenolic compounds. The optimized procedure involved 15 extractions using acetone:methanol:water (50:40:10, v/v/v) as solvent, a solid-liquid ratio of 1:9 (m/v) and an extraction time of 5 min. Validation data indicated that the HPLC method proposed provided good linearity, sensitivity, procedure accuracy, system precision and suggested its suitability for the simultaneous analysis of phenolic compounds and carotenoids in annatto seeds.

  8. Dark matter searches using superheated liquids

    NASA Astrophysics Data System (ADS)

    Manuel, Bou-Cabo; Miguel, Ardid; Ivan, Felis

    2016-07-01

    Direct detection of dark matter is one of the most important topics in modern physics. It is estimated that 22% of universe matter is composed by dark matter in front of 0.4% of ordinary matter like stars, galaxies planets and all kind of known astrophysical objects. Several kinds of experiments are nowadays involved in detection of one of the more accepted particle candidates to be dark matter: WIMPs (Weakly Interacting Massive Particles). These detectors, using several kinds of techniques: Cryogenic semiconductors, scintillation materials like I Na or noble gas chambers among others, are reporting very interesting but inconclusive results. In this paper a review of detectors that are using the superheated liquid technique in bubble chambers in order to detect WIMPs is reported. Basically, we will report about Coupp (Chicagoland observatory for underground particle physics), PICO that is composed by Coupp and Picasso researchers having the aim to build a ton experiment and also about a new detector named MOSCAB (Materia oscura a bolle) that recently published a first results of a test chamber that uses also superheated liquid technique but as a Geyser chamber.

  9. Noble Metal Nanoparticles for Biosensing Applications

    PubMed Central

    Doria, Gonçalo; Conde, João; Veigas, Bruno; Giestas, Leticia; Almeida, Carina; Assunção, Maria; Rosa, João; Baptista, Pedro V.

    2012-01-01

    In the last decade the use of nanomaterials has been having a great impact in biosensing. In particular, the unique properties of noble metal nanoparticles have allowed for the development of new biosensing platforms with enhanced capabilities in the specific detection of bioanalytes. Noble metal nanoparticles show unique physicochemical properties (such as ease of functionalization via simple chemistry and high surface-to-volume ratios) that allied with their unique spectral and optical properties have prompted the development of a plethora of biosensing platforms. Additionally, they also provide an additional or enhanced layer of application for commonly used techniques, such as fluorescence, infrared and Raman spectroscopy. Herein we review the use of noble metal nanoparticles for biosensing strategies—from synthesis and functionalization to integration in molecular diagnostics platforms, with special focus on those that have made their way into the diagnostics laboratory. PMID:22438731

  10. Novel MRI Applications of Laser-Polarized Noble Gases

    NASA Astrophysics Data System (ADS)

    Mair, R. W.; Walsworth, R. L.

    2002-04-01

    Gas-phase NMR has great potential as a probe for a variety of interesting physical and biomedical problems that are not amenable to study by water or similar liquid. However, NMR of gases was largely neglected due to the low signal obtained from the thermally-polarized gases with very low sample density. The advent of optical pumping techniques for enhancing the polarization of the noble gases 3He and 129Xe has bought new life to this field, especially in medical imaging where 3He lung inhalation imaging is approaching a clinical application. However, there are numerous applications in materials science that also benefit from the use of these gases. We review primarily non-medical applications of laser-polarized noble gases for both NMR imaging and spectroscopy, and highlight progress with examples from our laboratory including high-resolution imaging at mT applied field strength and velocity imaging of convective flow. Porous media microstucture has been probed with both thermal and laser-polarized xenon, as xenon is an ideal probe due to low surface interaction with the grains of the porous media.

  11. A comparison of digital zero-crossing and charge-comparison methods for neutron/γ-ray discrimination with liquid scintillation detectors

    NASA Astrophysics Data System (ADS)

    Nakhostin, M.

    2015-10-01

    In this paper, we have compared the performances of the digital zero-crossing and charge-comparison methods for n/γ discrimination with liquid scintillation detectors at low light outputs. The measurements were performed with a 2″×2″ cylindrical liquid scintillation detector of type BC501A whose outputs were sampled by means of a fast waveform digitizer with 10-bit resolution, 4 GS/s sampling rate and one volt input range. Different light output ranges were measured by operating the photomultiplier tube at different voltages and a new recursive algorithm was developed to implement the digital zero-crossing method. The results of our study demonstrate the superior performance of the digital zero-crossing method at low light outputs when a large dynamic range is measured. However, when the input range of the digitizer is used to measure a narrow range of light outputs, the charge-comparison method slightly outperforms the zero-crossing method. The results are discussed in regard to the effects of the quantization noise and the noise filtration performance of the zero-crossing filter.

  12. Determination of guanine and adenine by high-performance liquid chromatography with a self-fabricated wall-jet/thin-layer electrochemical detector at a glassy carbon electrode.

    PubMed

    Zhou, Yaping; Yan, Hongling; Xie, Qingji; Yao, Shouzhuo

    2015-03-01

    A sensitive wall-jet/thin-layer amperometric electrochemical detector (ECD) coupled to high-performance liquid chromatography (HPLC) was developed for simultaneous determination of guanine (G) and adenine (A). The analytes were detected at a glassy carbon electrode (GCE) and the HPLC-ECD calibration curves showed good linearity (R(2)>0.997) under optimized conditions. Limits of detection for G and A are 0.6 nM and 1.4 nM (S/N=3), respectively, which are lower than those obtained with an UV-vis detector and a commercial electrochemical detector. We have successfully applied this HPLC-ECD to assess the contents of G and A in hydrochloric acid-digested calf thymus double-stranded DNA. In addition, we compared in detail the analysis of G and A by cyclic voltammetry (CV) and by the HPLC-ECD system on both bare GCE and electroreduced graphene oxide (ERGO) modified GCE. We found that the adsorption of G and A on the electrode surfaces can vary their anodic CV peaks and the competitive adsorption of G and A on the limited sites of the electrode surfaces can cause crosstalk effects on their anodic CV peak signals, but the HPLC-ECD system is insensitive to such electrode-adsorption and can give more reliable analytical results.

  13. MO-A-BRD-01: An Investigation of the Dynamic Response of a Novel Acousto-Optic Liquid Crystal Detector for Full-Field Transmission Ultrasound Breast Imaging

    SciTech Connect

    Rosenfield, J.R.; La Riviere, P.J.; Sandhu, J.S.

    2014-06-15

    Purpose: To characterize the dynamic response of a novel acousto-optic (AO) liquid crystal detector for high-resolution transmission ultrasound breast imaging. Transient and steady-state lesion contrast were investigated to identify optimal transducer settings for our prototype imaging system consistent with the FDA limits of 1 W/cm{sup 2} and 50 J/cm{sup 2} on the incident acoustic intensity and the transmitted acoustic energy flux density. Methods: We have developed a full-field transmission ultrasound breast imaging system that uses monochromatic plane-wave illumination to acquire projection images of the compressed breast. The acoustic intensity transmitted through the breast is converted into a visual image by a proprietary liquid crystal detector operating on the basis of the AO effect. The dynamic response of the AO detector in the absence of an imaged breast was recorded by a CCD camera as a function of the acoustic field intensity and the detector exposure time. Additionally, a stereotactic needle biopsy breast phantom was used to investigate the change in opaque lesion contrast with increasing exposure time for a range of incident acoustic field intensities. Results: Using transducer voltages between 0.3 V and 0.8 V and exposure times of 3 minutes, a unique one-to-one mapping of incident acoustic intensity to steady-state optical brightness in the AO detector was observed. A transfer curve mapping acoustic intensity to steady-state optical brightness shows a high-contrast region analogous to the linear portion of the Hurter-Driffield curves of radiography. Using transducer voltages between 1 V and 1.75 V and exposure times of 90 s, the lesion contrast study demonstrated increasing lesion contrast with increasing breast exposure time and acoustic field intensity. Lesion-to-background contrast on the order of 0.80 was observed. Conclusion: Maximal lesion contrast in our prototype system can be obtained using the highest acoustic field intensity and the

  14. Angular correlation studies in noble gases

    NASA Technical Reports Server (NTRS)

    Coleman, P. G.

    1990-01-01

    There has been a recent revival of interest in the measurement of angular correlation of annihilation photons from the decay of positrons and positronium in gases. This revival has been stimulated by the possibility offered by the technique to shed new light on the apparently low positronium formation fraction in the heavier noble gases and to provide information on positronium quenching processes in gases such as oxygen. There is also the potential for learning about positronium slowing down in gases. This review focuses on experimental noble gas work and considers what new information has been, and may be, gained from these studies.

  15. DETERMINATION OF PHENOLS IN ENVIRONMENTALLY RELEVANT MATRICES WITH THE USE OF LIQUID CHROMATOGRAPHY WITH AN ENZYME ELECTRODE DETECTOR

    EPA Science Inventory

    A simple and rapid assay using HPLC with a tyrosinase-containing carbon paste electrode (Tyr-CPE) detector is demonstrated for the detection of phenol, p-cresol, p-methoxyphenol, and p-chlorophenol in environmental matrices. These compounds were measured in contaminated aqueous...

  16. A Grounded Theory of the Development of Noble Youth Purpose

    ERIC Educational Resources Information Center

    Bronk, Kendall Cotton

    2012-01-01

    Having a noble purpose in life is an important component of positive youth development; however, little is known about how noble purposes develop over time. Therefore, using three waves of interviews over a 5-year period with 9 adolescents (N = 9) who demonstrated intense commitments to various noble purposes, the present study developed a…

  17. The Colour of the Noble Metals.

    ERIC Educational Resources Information Center

    Poole, R. T.

    1983-01-01

    Examines the physical basis for colors of noble metals (copper, silver, gold) developed from energy conservation/quantum mechanical view of free electron photoabsorption. Describes production of absorption edges produced by change in density of occupied valence electron states in the d-band, which allows stronger absorption in the visible photon…

  18. MICROWAVE-ASSISTED SYNTHESIS OF NOBLE NANOSTRUCTURES

    EPA Science Inventory

    Microwave-assisted (MW) spontaneous reduction of noble metal salts, silver (Ag), gold (Au), platinum (Pt) and palladium (Pd) is reported using sugar solutions such as -D glucose, sucrose and maltose, etc. to generate nanomaterials. These MW-assisted reactions, conducted in aqueo...

  19. Natural Death and the Noble Savage.

    ERIC Educational Resources Information Center

    Walter, Tony

    1995-01-01

    The belief that dying and grieving are natural processes is widely held in modern bereavement care. Examines four assumption often made in this connection: (1) most primitive cultures deal with death in an accepting way; (2) this way is different than our own; (3) it is a good and noble way; and (4) traditional societies see death as natural. (JBJ)

  20. CONTROL ROD ALLOY CONTAINING NOBLE METAL ADDITIONS

    DOEpatents

    Anderson, W.K.; Ray, W.E.

    1960-05-01

    Silver-base alloys suitable for use in the fabrication of control rods for neutronic reactors are given. The alloy consists of from 0.5 wt.% to about 1.5 wt.% of a noble metal of platinum, ruthenium, rhodium, osmium, or palladium, up to 10 wt.% of cadmium, from 2 to 20 wt.% indium, the balance being silver.

  1. Preserving noble gases in a convecting mantle.

    PubMed

    Gonnermann, Helge M; Mukhopadhyay, Sujoy

    2009-05-28

    High (3)He/(4)He ratios sampled at many ocean islands are usually attributed to an essentially undegassed lower-mantle reservoir with high (3)He concentrations. A large and mostly undegassed mantle reservoir is also required to balance the Earth's (40)Ar budget, because only half of the (40)Ar produced from the radioactive decay of (40)K is accounted for by the atmosphere and upper mantle. However, geophysical and geochemical observations suggest slab subduction into the lower mantle, implying that most or all of Earth's mantle should have been processed by partial melting beneath mid-ocean ridges and hotspot volcanoes. This should have left noble gases in both the upper and the lower mantle extensively outgassed, contrary to expectations from (3)He/(4)He ratios and the Earth's (40)Ar budget. Here we suggest a simple solution: recycling and mixing of noble-gas-depleted slabs dilutes the concentrations of noble gases in the mantle, thereby decreasing the rate of mantle degassing and leaving significant amounts of noble gases in the processed mantle. As a result, even when the mass flux across the 660-km seismic discontinuity is equivalent to approximately one lower-mantle mass over the Earth's history, high (3)He contents, high (3)He/(4)He ratios and (40)Ar concentrations high enough to satisfy the (40)Ar mass balance of the Earth can be preserved in the lower mantle. The differences in (3)He/(4)He ratios between mid-ocean-ridge basalts and ocean island basalts, as well as high concentrations of (3)He and (40)Ar in the mantle source of ocean island basalts, can be explained within the framework of different processing rates for the upper and the lower mantle. Hence, to preserve primitive noble gas signatures, we find no need for hidden reservoirs or convective isolation of the lower mantle for any length of time.

  2. Rapid and sensitive liquid chromatographic method using a conductivity detector for the determination of phytic acid in food.

    PubMed

    Talamond, P; Gallon, G; Treche, S

    1998-05-01

    An LC method was developed for the determination of phytic acid in food. The separation was carried out by gradient elution on an anion-exchange column using a conductivity detector. Earlier reversed-phase LC procedures for the quantitation of phytic acid usually required a prepurification step. The prepurification can be avoided by the separation method described in this paper. The method is sensitive and selective, and can be rapidly and easily performed. It is therefore suitable for routine determination.

  3. High Performance Liquid Chromatography-Diode Array Detector Method for the Simultaneous Determination of Five Compounds in the Pulp and Seed of Sea Buckthorn

    PubMed Central

    Zhao, Lu; Wen, E; Upur, Halmuart; Tian, Shuge

    2017-01-01

    Context: Sea buckthorn (Hippophae rhamnoides L.) as a traditional Chinese medicinal plant has various uses in Xinjiang. Objective: A reversed-phase rapid-resolution liquid-chromatography method with diode array detector was developed for simultaneous determination of protocatechuic acid, rutin, quercetin, kaempferol, and isorhamnetin in the pulp and seed of sea buckthorn, a widely used traditional Chinese medicine for promoting metabolism and treating scurvy and other diseases. Settings and design: Compounds were separated on an Agilent ZORBAX SB-C18 column (4.6 mm × 250 mm, 5 μm; USA) with gradient elution using methanol and 0.4% phosphoric acid (v/v) at 1.0 mL/min. Detection wavelength was set at 280 nm. Materials and Methods: The fruits of wild sea buckthorn were collected from Wushi County in Aksu, Xinjiang Province. Statistical performances: The RSD of precision test of the five compounds were in the range of 0.60-2.22%, and the average recoveries ranged from 97.36% to 101.19%. Good linearity between specific chromatographic peak and component qualities were observed in the investigated ranges for all the analytes (R2 > 0.9997). Results: The proposed method was successfully applied to determine the levels of five active components in sea buckthorn samples from Aksu in Xinjiang. Conclusions: The proposed method is simple, fast, sensitive, accurate, and suitable for quantitative assessment of the pulp and seed of sea buckthorn. SUMMARY Quantitative analysis method of protocatechuic acid, rutin, quercetin, kaempferol, and isorhamnetin in the extract of sea buckthorn pulp and seed is developed by high-performance liquid chromatography (HPLC) diode array detection.This method is simple and accurate; has strong specificity, good precision, and high recovery rate; and provides a reliable basis for further development of the substances in the pulp and seed of sea buckthorn.The method is widely used for content determination of active ingredients or physiologically

  4. Improved solvent extraction procedure and high-performance liquid chromatography-evaporative light-scattering detector method for analysis of polar lipids from dairy materials.

    PubMed

    Le, Thien Trung; Miocinovic, Jelena; Nguyen, Tuyet Mai; Rombaut, Roeland; van Camp, John; Dewettinck, Koen

    2011-10-12

    A normal-phase high-performance liquid chromatography-evaporative light-scattering detector method employing dichloromethane, methanol, and acetic acid/triethylamine buffer as the mobile phase was developed for analysis of polar lipids (PLs). This method was applicable for analysis of PLs from both dairy materials and soy lecithin. All of the PLs of interest such as glycolipids, phospholipids, and sphingomyelin were well separated with a total run time of 22.5 min and without necessitating the removal of neutral lipids beforehand. Peak retention times were stable, and the method was reproducible. In this study, a modified method of using solvents for extraction of PLs from dairy matrices was also investigated. The modified method offered higher extraction efficiency, consumed less time, and in some cases saved solvent use.

  5. The light-yield response of a NE-213 liquid-scintillator detector measured using 2-6 MeV tagged neutrons

    NASA Astrophysics Data System (ADS)

    Scherzinger, J.; Al Jebali, R.; Annand, J. R. M.; Fissum, K. G.; Hall-Wilton, R.; Kanaki, K.; Lundin, M.; Nilsson, B.; Perrey, H.; Rosborg, A.; Svensson, H.

    2016-12-01

    The response of a NE-213 liquid-scintillator detector has been measured using tagged neutrons from 2 to 6 MeV originating from an Am/Be neutron source. The neutron energies were determined using the time-of-flight technique. Pulse-shape discrimination was employed to discern between gamma-rays and neutrons. The behavior of both the fast (35 ns) and the combined fast and slow (475 ns) components of the neutron scintillation-light pulses were studied. Three different prescriptions were used to relate the neutron maximum energy-transfer edges to the corresponding recoil-proton scintillation-light yields, and the results were compared to simulations. The overall normalizations of parametrizations which predict the fast or total light yield of the scintillation pulses were also tested. Our results agree with both existing data and existing parametrizations. We observe a clear sensitivity to the portion and length of the neutron scintillation-light pulse considered.

  6. Using second-order calibration method based on trilinear decomposition algorithms coupled with high performance liquid chromatography with diode array detector for determination of quinolones in honey samples.

    PubMed

    Yu, Yong-Jie; Wu, Hai-Long; Shao, Sheng-Zhi; Kang, Chao; Zhao, Juan; Wang, Yu; Zhu, Shao-Hua; Yu, Ru-Qin

    2011-09-15

    A novel strategy that combines the second-order calibration method based on the trilinear decomposition algorithms with high performance liquid chromatography with diode array detector (HPLC-DAD) was developed to mathematically separate the overlapped peaks and to quantify quinolones in honey samples. The HPLC-DAD data were obtained within a short time in isocratic mode. The developed method could be applied to determine 12 quinolones at the same time even in the presence of uncalibrated interfering components in complex background. To access the performance of the proposed strategy for the determination of quinolones in honey samples, the figures of merit were employed. The limits of quantitation for all analytes were within the range 1.2-56.7 μg kg(-1). The work presented in this paper illustrated the suitability and interesting potential of combining second-order calibration method with second-order analytical instrument for multi-residue analysis in honey samples.

  7. Search for 2 ν β β decay of 136Xe to the 01+ excited state of 136Ba with the EXO-200 liquid xenon detector

    NASA Astrophysics Data System (ADS)

    Albert, J. B.; Auty, D. J.; Barbeau, P. S.; Beck, D.; Belov, V.; Breidenbach, M.; Brunner, T.; Burenkov, A.; Cao, G. F.; Chambers, C.; Chaves, J.; Cleveland, B.; Coon, M.; Craycraft, A.; Daniels, T.; Danilov, M.; Daugherty, S. J.; Davis, J.; Delaquis, S.; Der Mesrobian-Kabakian, A.; DeVoe, R.; Didberidze, T.; Dilling, J.; Dolgolenko, A.; Dolinski, M. J.; Dunford, M.; Fairbank, W.; Farine, J.; Feldmeier, W.; Feyzbakhsh, S.; Fierlinger, P.; Fudenberg, D.; Gornea, R.; Graham, K.; Gratta, G.; Hall, C.; Hughes, M.; Jewell, M. J.; Johnson, A.; Johnson, T. N.; Johnston, S.; Karelin, A.; Kaufman, L. J.; Killick, R.; King, J.; Koffas, T.; Kravitz, S.; Krücken, R.; Kuchenkov, A.; Kumar, K. S.; Leonard, D. S.; Licciardi, C.; Lin, Y. H.; Ling, J.; MacLellan, R.; Marino, M. G.; Mong, B.; Moore, D.; Njoya, O.; Nelson, R.; Odian, A.; Ostrovskiy, I.; Piepke, A.; Pocar, A.; Prescott, C. Y.; Retière, F.; Rowson, P. C.; Russell, J. J.; Schubert, A.; Sinclair, D.; Smith, E.; Stekhanov, V.; Tarka, M.; Tolba, T.; Tsang, R.; Twelker, K.; Vogel, P.; Vuilleumier, J.-L.; Waite, A.; Walton, J.; Walton, T.; Weber, M.; Wen, L. J.; Wichoski, U.; Winick, T. A.; Wood, J.; Xu, Q. Y.; Yang, L.; Yen, Y.-R.; Zeldovich, O. Ya.; EXO-200 Collaboration

    2016-03-01

    EXO-200 is a single phase liquid xenon detector designed to search for neutrinoless β β decay of 136Xe to the ground state of 136Ba. We report here on a search for the two-neutrino β β decay of 136Xe to the first 0+ excited state, 01+, of 136Ba based on a 100 kg yr exposure of 136Xe. Using a specialized analysis employing a machine learning algorithm, we obtain a 90% CL half-life sensitivity of 1.7 ×1024 yr. We find no statistically significant evidence for the 2 ν β β decay to the excited state resulting in a lower limit of T1/2 2 ν (0+→01+) > 6.9 ×1023 yr at 90% CL. This observed limit is consistent with the estimated half-life of 2.5 ×1025 yr.

  8. FINGERPRINTING INORGANIC ARSENIC AND ORGANOARSENIC COMPOUNDS IN IN SITU OIL SHALE RETORT AND PROCESS VOTERS USING A LIQUID CHROMATOGRAPH COUPLED WITH AN ATOMIC ABSORPTION SPECTROMETER AS A DETECTOR

    SciTech Connect

    Fish, Richard H.; Brinckman, Frederick E.; Jewett, Kenneth L.

    1981-07-01

    Inorganic arsenic and organoarsenic compounds were speciated in seven oil shale retort and process waters, including samples from simulated, true and modified in situ processes, using a high performance liquid chromatograph automatically coupled to a graphite furnace atomic absorption detector. The molecular forms of arsenic at ppm levels (({micro}g/mL) in these waters are identified for the first time, and shown to include arsenate, methylarsonic acid and phenylarsonic acid. An arsenic-specific fingerprint chromatogram of each retort or process water studied has significant impliestions regarding those arsenical species found and those marginally detected, such as dimethylarsinic acid and the suspected carcinogen arsenite. The method demonstrated suggests future means for quantifying environmental impacts of bioactive organometal species involved in oil shale retorting technology.

  9. Quantitative and chemical fingerprint analysis for the quality evaluation of Isatis indigotica based on ultra-performance liquid chromatography with photodiode array detector combined with chemometric methods.

    PubMed

    Shi, Yan-Hong; Xie, Zhi-Yong; Wang, Rui; Huang, Shan-Jun; Li, Yi-Ming; Wang, Zheng-Tao

    2012-01-01

    A simple and reliable method of ultra-performance liquid chromatography with photodiode array detector (UPLC-PDA) was developed to control the quality of Radix Isatidis (dried root of Isatis indigotica) for chemical fingerprint analysis and quantitative analysis of eight bioactive constituents, including R,S-goitrin, progoitrin, epiprogoitrin, gluconapin, adenosine, uridine, guanosine, and hypoxanthine. In quantitative analysis, the eight components showed good regression (R > 0.9997) within test ranges, and the recovery method ranged from 99.5% to 103.0%. The UPLC fingerprints of the Radix Isatidis samples were compared by performing chemometric procedures, including similarity analysis, hierarchical clustering analysis, and principal component analysis. The chemometric procedures classified Radix Isatidis and its finished products such that all samples could be successfully grouped according to crude herbs, prepared slices, and adulterant Baphicacanthis cusiae Rhizoma et Radix. The combination of quantitative and chromatographic fingerprint analysis can be used for the quality assessment of Radix Isatidis and its finished products.

  10. Optimized Mie potentials for phase equilibria: Application to noble gases and their mixtures with n-alkanes.

    PubMed

    Mick, Jason R; Soroush Barhaghi, Mohammad; Jackman, Brock; Rushaidat, Kamel; Schwiebert, Loren; Potoff, Jeffrey J

    2015-09-21

    Transferrable force fields, based on n-6 Mie potentials, are presented for noble gases. By tuning the repulsive exponent, ni, it is possible to simultaneously reproduce experimental saturated liquid densities and vapor pressures with high accuracy, from the normal boiling point to the critical point. Vapor-liquid coexistence curves for pure fluids are calculated using histogram reweighting Monte Carlo simulations in the grand canonical ensemble. For all noble gases, saturated liquid densities and vapor pressures are reproduced to within 1% and 4% of experiment, respectively. Radial distribution functions, extracted from NVT and NPT Monte Carlo simulations, are in similarly excellent agreement with experimental data. The transferability of the optimized force fields is assessed through calculations of binary mixture vapor-liquid equilibria. These mixtures include argon + krypton, krypton + xenon, methane + krypton, methane + xenon, krypton + ethane, and xenon + ethane. For all mixtures, excellent agreement with experiment is achieved without the introduction of any binary interaction parameters or multi-body interactions.

  11. Organic liquid scintillation detectors for on-the-fly neutron/gamma alarming and radionuclide identification in a pedestrian radiation portal monitor

    NASA Astrophysics Data System (ADS)

    Paff, Marc Gerrit; Ruch, Marc L.; Poitrasson-Riviere, Alexis; Sagadevan, Athena; Clarke, Shaun D.; Pozzi, Sara

    2015-07-01

    We present new experimental results from a radiation portal monitor based on the use of organic liquid scintillators. The system was tested as part of a 3He-free radiation portal monitor testing campaign at the European Commission's Joint Research Centre in Ispra, Italy, in February 2014. The radiation portal monitor was subjected to a wide range of test conditions described in ANSI N42.35, including a variety of gamma-ray sources and a 20,000 n/s 252Cf source. A false alarm test tested whether radiation portal monitors ever alarmed in the presence of only natural background. The University of Michigan Detection for Nuclear Nonproliferation Group's system triggered zero false alarms in 2739 trials. It consistently alarmed on a variety of gamma-ray sources travelling at 1.2 m/s at a 70 cm source to detector distance. The neutron source was detected at speeds up to 3 m/s and in configurations with up to 8 cm of high density polyethylene shielding. The success of on-the-fly radionuclide identification varied with the gamma-ray source measured as well as with which of two radionuclide identification methods was used. Both methods used a least squares comparison between the measured pulse height distributions to library spectra to pick the best match. The methods varied in how the pulse height distributions were modified prior to the least squares comparison. Correct identification rates were as high as 100% for highly enriched uranium, but as low as 50% for 241Am. Both radionuclide identification algorithms produced mixed results, but the concept of using liquid scintillation detectors for gamma-ray and neutron alarming in radiation portal monitor was validated.

  12. First results of a large-area cryogenic gaseous photomultiplier coupled to a dual-phase liquid xenon TPC

    NASA Astrophysics Data System (ADS)

    Arazi, L.; Coimbra, A. E. C.; Erdal, E.; Israelashvili, I.; Rappaport, M. L.; Shchemelinin, S.; Vartsky, D.; dos Santos, J. M. F.; Breskin, A.

    2015-10-01

    We discuss recent advances in the development of cryogenic gaseous photomultipliers (GPM), for possible use in dark matter and other rare-event searches using noble-liquid targets. We present results from a 10 cm diameter GPM coupled to a dual-phase liquid xenon (LXe) TPC, demonstrating—for the first time—the feasibility of recording both primary (``S1'') and secondary (``S2'') scintillation signals. The detector comprised a triple Thick Gas Electron Multiplier (THGEM) structure with cesium iodide photocathode on the first element; it was shown to operate stably at 180 K with gains above 105, providing high single-photon detection efficiency even in the presence of large α particle-induced S2 signals comprising thousands of photoelectrons. S1 scintillation signals were recorded with a time resolution of 1.2 ns (RMS). The energy resolution (σ/E) for S2 electroluminescence of 5.5 MeV α particles was ~ 9%, which is comparable to that obtained in the XENON100 TPC with PMTs. The results are discussed within the context of potential GPM deployment in future multi-ton noble-liquid detectors.

  13. Quality evaluation of Radix Stemonae through simultaneous quantification of bioactive alkaloids by high-performance liquid chromatography coupled with diode array and evaporative light scattering detectors.

    PubMed

    Li, Song-Lin; Jiang, Ren-Wang; Hon, Po-Ming; Cheng, Ling; Xu, Hong-Xi; Greger, Harald; But, Paul Pui-Hay; Shaw, Pang-Chui

    2007-10-01

    A high-performance liquid chromatography coupled with diode array detection and evaporative light scattering detection (HPLC-DAD-ELSD) method was developed to simultaneously quantify six major bioactive alkaloids belonging to different structure types in Radix Stemonae, Bai-Bu in Chinese, a traditionally used antitussive and insecticidal medicinal material in China and other countries of Southeast Asia. Diode array detector (DAD) with the wavelengths at 307 and 260 nm was used to monitor the conjugated system of protostemonine (2) and maistemonine (4), respectively, whereas evaporative light scattering detector (ELSD) was employed to detect croomine (1), stemoninine (3), neotuberostemonine (5) and tuberostemonine (6), the other four analytes with no or poor chromophores. The assay was validated to be sensitive, precise and accurate, with a detection limit of 3.64-0.04 microg/mL depending on the individual analytes. The overall intra- and inter-day variations were less than 9.3%, and the overall recoveries higher than 91.2%, respectively. The correlation coefficients of the calibration curves were better than 0.996 for all analytes. The newly established method was successfully utilized to determine six major components in the genuine sources of Radix Stemonae: Stemona japonica, S. sessilifolia and S. tuberosa. Significant variations of contents of these components were demonstrated in samples of these three species. This simple, rapid, low-cost and reliable method is suitable for the routine quality control of herbal medicines containing bioactive components with different structure types such as Radix Stemonae.

  14. Demonstration and comparison of photomultiplier tubes at liquid Argon temperature

    NASA Astrophysics Data System (ADS)

    Acciarri, R.; Antonello, M.; Boffelli, F.; Cambiaghi, M.; Canci, N.; Cavanna, F.; Cocco, A. G.; Deniskina, N.; Di Pompeo, F.; Fiorillo, G.; Galbiati, C.; Grandi, L.; Kryczynski, P.; Meng, G.; Montanari, C.; Palamara, O.; Pandola, L.; Perfetto, F.; Piano Mortari, G. B.; Pietropaolo, F.; Raselli, G. L.; Rubbia, C.; Segreto, E.; Szelc, A. M.; Triossi, A.; Ventura, S.; Vignoli, C.; Zani, A.

    2012-01-01

    Liquified noble gases are widely used as a target in direct Dark Matter searches. Signals from scintillation in the liquid, following energy deposition from the recoil nuclei scattered by Dark Matter particles (e.g. WIMPs), should be recorded down to very low energies by photosensors suitably designed to operate at cryogenic temperatures. Liquid Argon based detectors for Dark Matter searches currently implement photomultiplier tubes for signal read-out. In the last few years PMTs with photocathodes operating down to liquid Argon temperatures (87 K) have been specially developed with increasing Quantum Efficiency characteristics. The most recent of these, Hamamatsu Photonics K.K. Mod. R11065 with peak QE up to about 35%, has been extensively tested within the R&D program of the WArP Collaboration. During these tests the Hamamatsu PMTs showed excellent performance and allowed obtaining a light yield around 7 phel/keVee in a Liquid Argon detector with a photocathodic coverage in the 12% range, sufficient for detection of events down to few keVee of energy deposition. This shows that this new type of PMT is suited for experimental applications, in particular for new direct Dark Matter searches with LAr-based experiments.

  15. Oscillator detector

    SciTech Connect

    Potter, B.M.

    1980-05-13

    An alien liquid detector employs a monitoring element and an oscillatory electronic circuit for maintaining the temperature of the monitoring element substantially above ambient temperature. The output wave form, eg., frequency of oscillation or wave shape, of the oscillatory circuit depends upon the temperaturedependent electrical characteristic of the monitoring element. A predetermined change in the output waveform allows water to be discriminated from another liquid, eg., oil. Features of the invention employing two thermistors in two oscillatory circuits include positioning one thermistor for contact with water and the other thermistor above the oil-water interface to detect a layer of oil if present. Unique oscillatory circuit arrangements are shown that achieve effective thermistor action with an economy of parts and energizing power. These include an operational amplifier employed in an astable multivibrator circuit, a discrete transistor-powered tank circuit, and use of an integrated circuit chip.

  16. Highly Fluorescent Noble Metal Quantum Dots

    PubMed Central

    Zheng, Jie; Nicovich, Philip R.; Dickson, Robert M.

    2009-01-01

    Highly fluorescent, water-soluble, few-atom noble metal quantum dots have been created that behave as multi-electron artificial atoms with discrete, size-tunable electronic transitions throughout the visible and near IR. These “molecular metals” exhibit highly polarizable transitions and scale in size according to the simple relation, Efermi/N1/3, predicted by the free electron model of metallic behavior. This simple scaling indicates that fluorescence arises from intraband transitions of free electrons and that these conduction electron transitions are the low number limit of the plasmon – the collective dipole oscillations occurring when a continuous density of states is reached. Providing the “missing link” between atomic and nanoparticle behavior in noble metals, these emissive, water-soluble Au nanoclusters open new opportunities for biological labels, energy transfer pairs, and light emitting sources in nanoscale optoelectronics. PMID:17105412

  17. Where do noble gases hide in space?

    NASA Astrophysics Data System (ADS)

    Pauzat, F.; Ellinger, Y.

    Observations showing anomalous amounts of noble gas, especially in planetary atmospheres, are at the origin of a series of controversial interpretations from 1990 to nowadays (Hersant et al. (2004)). If, in a first step, we adopt a chemical point of view, we have to consider the possibility of associations of such elements (though usually considered as non reactive), with other molecules or atoms. Such complexes could trap the noble gases in some astrophysical objects at one time of their evolution, for example, in the early step of formation of protoplanetary disks. But two questions have to be answered to assert this type of hypothesis: which stable compounds could exist taking into account the environnement and which reactions could lead to such compounds? Hydrogen being by far the most abundant element in space, and neutral systems whose cohesion is driven by weak Van der Waals forces being unable to resist turbulence in space, the first and simplest association to consider is the one between the noble gas and the H3+ ion. Thus, DFT in the B3LYP, PW91 and BHandHLYP formalisms together with ab-initio methods of Coupled Cluster type have been employed to determine the equilibrium geometries, the spectroscopic constants and the bonding energies of the possible complexes between noble gases and hydrogen. We have first performed an extensive study of the associations ArnH3+ possible with Argon (the first noble gas which rose questions in the area of Jupiter's poles). We have found that several Argon atoms can be stabilized around the H3+ ion, the first complexation being in the plane of the ion. The spectroscopic data (rotational constants, dipole moments and IR signatures) were calculated (Pauzat & Ellinger (2005)) so that the laboratory experiments and spatial observations of these species could then be carried out. From our results and previous observations on this complex (Bogey et al. (1987)) we can say that the ArH3+ ion is certainly a good candidate for

  18. Simultaneous determination three phytosterol compounds, campesterol, stigmasterol and daucosterol in Artemisia apiacea by high performance liquid chromatography-diode array ultraviolet/visible detector

    PubMed Central

    Lee, Jiwoo; Weon, Jin Bae; Yun, Bo-Ra; Eom, Min Rye; Ma, Choong Je

    2015-01-01

    Background: Artemisia apiacea is a traditional herbal medicine using treatment of eczema and jaundice in Eastern Asia, including China, Korea, and Japan. Objective: An accurate and sensitive analysis method using high performance liquid chromatography-diode array ultraviolet/visible detector and liquid chromatography–mass spectrometry for the simultaneous determination of three phytosterol compounds, campesterol, stigmasterol and daucosterol in A. apiacea was established. Materials and Methods: The analytes were separated on a Shiseido C18 column (5 μm, 4.6 mm I.D. ×250 mm) with gradient elution of 0.1% trifluoroacetic acid and acetonitrile. The flow rate was 1 mL/min and detection wavelengths were set at 205 and 254 nm. Results: Validation of the method was performed to demonstrate its linearity, precision and accuracy. The calibration curves showed good linearity (R2 > 0.9994). The limits of detection and limits of quantification were within the ranges 0.55–7.07 μg/mL and 1.67–21.44 μg/mL, respectively. And, the relative standard deviations of intra- and inter-day precision were <2.93%. The recoveries were found to be in the range of 90.03–104.91%. Conclusion: The developed method has been successfully applied to the analysis for quality control of campesterol, stigmasterol and daucosterol in A. apiacea. PMID:25829768

  19. Design and implementation of an array of micro-electrochemical detectors for two-dimensional liquid chromatography-proof of principle

    SciTech Connect

    Putnam, Joe; Mriziq, Khaled S; Guiochon, Georges A

    2010-01-01

    Simultaneous two-dimensional liquid chromatography (2D-LC) is an implementation of two-dimensional liquid chromatography which has the potential to provide very fast, yet highly efficient separations. It is based on the use of time x space and space x space separation systems. The basic principle of this instrument has been validated long ago by the success of two-dimensional thin layer chromatography. The construction of a pressurized wide and flat column (100 mm x 100 mm x 1 mm) operated under an inlet pressure of up to 50 bar was described previously. However, to become a modern analytical method, simultaneous 2D-LC requires the development of detectors suitable for the monitoring of the composition of the eluent of this pressurized planar, wide column. An array of five equidistant micro-electrochemical sensors was built for this purpose and tested. Each sensor is a three-electrode system, with the working electrode being a 25 {micro}m polished platinum micro-electrode. The auxiliary electrode is a thin platinum wire and the reference electrode an Ag/AgCl (3 M sat. KCl) electrode. In this first implementation, proof of principle is demonstrated, but the final instrument will require a much larger array.

  20. A measurement of the time profile of scintillation induced by low energy gamma-rays in liquid xenon with the XMASS-I detector

    NASA Astrophysics Data System (ADS)

    Takiya, H.; Abe, K.; Hiraide, K.; Ichimura, K.; Kishimoto, Y.; Kobayashi, K.; Kobayashi, M.; Moriyama, S.; Nakahata, M.; Norita, T.; Ogawa, H.; Sekiya, H.; Takachio, O.; Takeda, A.; Tasaka, S.; Yamashita, M.; Yang, B. S.; Kim, N. Y.; Kim, Y. D.; Itow, Y.; Kegasa, R.; Kobayashi, K.; Masuda, K.; Fushimi, K.; Martens, K.; Suzuki, Y.; Fujita, R.; Hosokawa, K.; Miuchi, K.; Oka, N.; Onishi, Y.; Takeuchi, Y.; Kim, Y. H.; Lee, J. S.; Lee, K. B.; Lee, M. K.; Fukuda, Y.; Nishijima, K.; Nakamura, S.

    2016-10-01

    We report the measurement of the emission time profile of scintillation from gamma-ray induced events in the XMASS-I 832 kg liquid xenon scintillation detector. Decay time constant was derived from a comparison of scintillation photon timing distributions between the observed data and simulated samples in order to take into account optical processes such as absorption and scattering in liquid xenon. Calibration data of radioactive sources, 55Fe, 241Am, and 57Co were used to obtain the decay time constant. Assuming two decay components, τ1 and τ2, the decay time constant τ2 increased from 27.9 ns to 37.0 ns as the gamma-ray energy increased from 5.9 keV to 122 keV. The accuracy of the measurement was better than 1.5 ns at all energy levels. A fast decay component with τ1 ∼ 2 ns was necessary to reproduce data. Energy dependencies of τ2 and the fraction of the fast decay component were studied as a function of the kinetic energy of electrons induced by gamma-rays. The obtained data almost reproduced previously reported results and extended them to the lower energy region relevant to direct dark matter searches.

  1. On calibration of the response of liquid argon detectors to nuclear recoils using inelastic neutron scattering on 40Ar

    NASA Astrophysics Data System (ADS)

    Polosatkin, S.; Grishnyaev, E.; Dolgov, A.

    2014-10-01

    A method for measuring of ionization and scintillation yields in liquid argon from recoils with particular energy—8.2 keV—is proposed. The method utilizes a process of inelastic scattering of monoenergetic neutrons produced by fusion DD neutron generator. Features of kinematics of inelastic scattering result in a sufficient (fifteen times) increase in count rate of useful events relative to a traditional scheme using elastic scattering with the same recoil energy and comparable energy resolution.

  2. Noble Gases in the Chelyabinsk Meteorites

    NASA Technical Reports Server (NTRS)

    Haba, Makiko K.; Sumino, Hirochika; Nagao, Keisuke; Mikouchi, Takashi; Komatsu, Mutsumi; Zolensky, Michael E.

    2014-01-01

    The Chelyabinsk meteorite fell in Russia on February 15, 2013 and was classified as LL5 chondrite. The diameter before it entered the atmosphere has been estimated to be about 20 m [1]. Up to now, numerous fragments weighing much greater than 100 kg in total have been collected. In this study, all noble gases were measured for 13 fragments to investigate the exposure history of the Chelyabinsk meteorite and the thermal history of its parent asteroid.

  3. Adaptors for radiation detectors

    DOEpatents

    Livesay, Ronald Jason

    2015-07-28

    Described herein are adaptors and other devices for radiation detectors that can be used to make accurate spectral measurements of both small and large bulk sources of radioactivity, such as building structures, soils, vessels, large equipment, and liquid bodies. Some exemplary devices comprise an adaptor for a radiation detector, wherein the adaptor can be configured to collimate radiation passing through the adapter from an external radiation source to the radiation detector and the adaptor can be configured to enclose a radiation source within the adapter to allow the radiation detector to measure radiation emitted from the enclosed radiation source.

  4. Adaptors for radiation detectors

    DOEpatents

    Livesay, Ronald Jason

    2014-04-22

    Described herein are adaptors and other devices for radiation detectors that can be used to make accurate spectral measurements of both small and large bulk sources of radioactivity, such as building structures, soils, vessels, large equipment, and liquid bodies. Some exemplary devices comprise an adaptor for a radiation detector, wherein the adaptor can be configured to collimate radiation passing through the adapter from an external radiation source to the radiation detector and the adaptor can be configured to enclose a radiation source within the adapter to allow the radiation detector to measure radiation emitted from the enclosed radiation source.

  5. Neutrino Detectors

    NASA Astrophysics Data System (ADS)

    von Feilitzsch, Franz; Lanfranchi, Jean-Côme; Wurm, Michael

    The neutrino was postulated by Wolfgang Pauli in the early 1930s, but could only be detected for the first time in the 1950s. Ever since scientists all around the world have worked on the detection and understanding of this particle which so scarcely interacts with matter. Depending on the origin and nature of the neutrino, various types of experiments have been developed and operated. In this entry, we will review neutrino detectors in terms of neutrino energy and associated detection technique as well as the scientific outcome of some selected examples. After a brief historical introduction, the detection of low-energy neutrinos originating from nuclear reactors or from the Earth is used to illustrate the principles and difficulties which are encountered in detecting neutrinos. In the context of solar neutrino spectroscopy, where the neutrino is used as a probe for astrophysics, three different types of neutrino detectors are presented - water Čerenkov, radiochemical, and liquid-scintillator detectors. Moving to higher neutrino energies, we discuss neutrinos produced by astrophysical sources and from accelerators. The entry concludes with an overview of a selection of future neutrino experiments and their scientific goals.

  6. Measurement of the drift velocity and transverse diffusion of electrons in liquid xenon with the EXO-200 detector

    NASA Astrophysics Data System (ADS)

    Albert, J. B.; Barbeau, P. S.; Beck, D.; Belov, V.; Breidenbach, M.; Brunner, T.; Burenkov, A.; Cao, G. F.; Cen, W. R.; Chambers, C.; Cleveland, B.; Coon, M.; Craycraft, A.; Daniels, T.; Danilov, M.; Daugherty, S. J.; Daughhetee, J.; Davis, J.; Delaquis, S.; Der Mesrobian-Kabakian, A.; DeVoe, R.; Didberidze, T.; Dilling, J.; Dolgolenko, A.; Dolinski, M. J.; Dunford, M.; Fairbank, W.; Farine, J.; Feyzbakhsh, S.; Fierlinger, P.; Fudenberg, D.; Gornea, R.; Graham, K.; Gratta, G.; Hall, C.; Hughes, M.; Jewell, M. J.; Johnson, A.; Johnson, T. N.; Johnston, S.; Karelin, A.; Kaufman, L. J.; Killick, R.; Koffas, T.; Kravitz, S.; Krücken, R.; Kuchenkov, A.; Kumar, K. S.; Lan, Y.; Leonard, D. S.; Licciardi, C.; Lin, Y. H.; MacLellan, R.; Marino, M. G.; Mong, B.; Moore, D.; Njoya, O.; Nelson, R.; Odian, A.; Ostrovskiy, I.; Piepke, A.; Pocar, A.; Prescott, C. Y.; Retière, F.; Rowson, P. C.; Russell, J. J.; Schubert, A.; Sinclair, D.; Smith, E.; Stekhanov, V.; Tarka, M.; Tolba, T.; Tsang, R.; Twelker, K.; Vuilleumier, J.-L.; Waite, A.; Walton, J.; Walton, T.; Weber, M.; Wen, L. J.; Wichoski, U.; Wood, J.; Yang, L.; Yen, Y.-R.; Zeldovich, O. Ya.; Zettlemoyer, J.; EXO-200 Collaboration

    2017-02-01

    The EXO-200 Collaboration is searching for neutrinoless double β decay using a liquid xenon (LXe) time projection chamber. This measurement relies on modeling the transport of charge deposits produced by interactions in the LXe to allow discrimination between signal and background events. Here we present measurements of the transverse diffusion constant and drift velocity of electrons at drift fields between 20 V/cm and 615 V/cm using EXO-200 data. At the operating field of 380 V/cm EXO-200 measures a drift velocity of 1 .705-0.010+0.014mm /μ s and a transverse diffusion coefficient of 55 ±4 cm2 /s.

  7. ORIGIN OF THERMAL FLUIDS AT LASSEN VOLCANIC NATIONAL PARK: EVIDENCE FROM NOBLE AND REACTIVE GAS ABUNDANCES.

    USGS Publications Warehouse

    Truesdell, Alfred H.; Mazor, Emanuel; Nehring, Nancy L.

    1983-01-01

    Thermal fluid discharges at Lassen are dominated by high-altitude fumaroles and acid-sulfate hot springs in the Park, and lower altitude, neutral, high-chloride hot springs in Mill Valley 7-10 km to the south. The interrelations of these fluids have been studied by noble and reactive gas analyses. Atmospheric noble gas (ANG) contents of superheated fumaroles are similar to those of air-saturated recharge water (ASW) at 5 degree C and 2500-m elevation. Low-elevation, high-chloride, hot-spring waters are highly depleted in ANG, relative to the ASW. The surface temperatures and gas chemistry of the fumaroles and hot springs suggest that steam originating from partial to near-complete vaporization of liquid from a boiling, high-chloride, hot water aquifer is decompressed adiabatically, and more or less mixed with shallow groundwater to form superheated and drowned fumaroles within the Park. Refs.

  8. Protein-protected luminescent noble metal quantum clusters: an emerging trend in atomic cluster nanoscience.

    PubMed

    Xavier, Paulrajpillai Lourdu; Chaudhari, Kamalesh; Baksi, Ananya; Pradeep, Thalappil

    2012-01-01

    Noble metal quantum clusters (NMQCs) are the missing link between isolated noble metal atoms and nanoparticles. NMQCs are sub-nanometer core sized clusters composed of a group of atoms, most often luminescent in the visible region, and possess intriguing photo-physical and chemical properties. A trend is observed in the use of ligands, ranging from phosphines to functional proteins, for the synthesis of NMQCs in the liquid phase. In this review, we briefly overview recent advancements in the synthesis of protein protected NMQCs with special emphasis on their structural and photo-physical properties. In view of the protein protection, coupled with direct synthesis and easy functionalization, this hybrid QC-protein system is expected to have numerous optical and bioimaging applications in the future, pointers in this direction are visible in the literature.

  9. Calibration of stack monitors for measurement of noble gases in nuclear facilities.

    PubMed

    Kovar, Petr; Dryak, Pavel; Suran, Jiri; Gudelis, Arunas

    2012-09-01

    In nuclear facilities stack monitors are used for the measurement of the volumetric activity of noble gases. Spectrometric measurement is needed because the content of stack effluents is always a mixture of radionuclides. In some nuclear power plants new types of monitors were installed based on HPGe detectors. For efficiency calibration a standard with the radionuclide Xe-127 was developed and calibration curve constructed in the energy range 81 keV-1293 keV. Experiental efficiencies were checked using an MC model.

  10. Selective extraction and analysis of catecholamines in rat blood microdialysate by polymeric ionic liquid-diphenylboric acid-packed capillary column and fast separation in high-performance liquid chromatography-electrochemical detector.

    PubMed

    Zhou, Xinguang; Zhu, Anwei; Shi, Guoyue

    2015-08-28

    Concentration of blood catecholamines (CAs) is linked to a host of cardiovascular diseases, including hypertension and stenocardia. The matrix interferences and low concentration require tedious sample pretreatment methods before quantitative analysis by the gold standard method of high-performance liquid chromatography-electrochemical detector (HPLC-ECD). Solid phase extraction (SPE) has been widely used as the pretreatment technique. Here, a facile polymeric ionic liquid (PIL)-diphenylboric acid (DPBA)-packed capillary column was prepared to selectively extract dopamine (DA), noradrenaline (NE) and epinephrine (E) prior to their quantitative analysis by a fast separation in HPLC-ECD method, while microdialysis sampling method was applied to get the analysis sample. Parameters that influenced desorption efficiency, such as pH, salt concentration, acetonitrile content and wash time, were examined and optimized. The proposed method, combining microdialysis sampling technique, SPE and HPLC-ECD system, was successfully applied to detect CAs in rat blood microdialysate with high sensitivity and selectivity in small sample volumes (5-40μl) and a short analysis time (8min), yielding good reproducibility (RSD 6.5-7.7%) and spiked recovery (91-104.4%).

  11. The Upgraded D0 detector

    SciTech Connect

    Abazov, V.M.; Abbott, B.; Abolins, M.; Acharya, B.S.; Adams, D.L.; Adams, M.; Adams, T.; Agelou, M.; Agram, J.-L.; Ahmed, S.N.; Ahn, S.H.; Ahsan, M.; Alexeev, G.D.; Alkhazov, G.; Alton, A.; Alverson, G.; Alves, G.A.; Anastasoaie, M.; Andeen, T.; Anderson, J.T.; Anderson, S.; /Buenos Aires U. /Rio de Janeiro, CBPF /Sao Paulo, IFT /Alberta U. /Simon Fraser U. /York U., Canada /McGill U. /Beijing, Inst. High Energy Phys. /Hefei, CUST /Andes U., Bogota /Charles U. /Prague, Tech. U. /Prague, Inst. Phys. /San Francisco de Quito U. /Clermont-Ferrand U. /LPSC, Grenoble /Marseille, CPPM /Orsay, LAL /Paris U., VI-VII /DAPNIA, Saclay /Strasbourg, IReS

    2005-07-01

    The D0 experiment enjoyed a very successful data-collection run at the Fermilab Tevatron collider between 1992 and 1996. Since then, the detector has been upgraded to take advantage of improvements to the Tevatron and to enhance its physics capabilities. We describe the new elements of the detector, including the silicon microstrip tracker, central fiber tracker, solenoidal magnet, preshower detectors, forward muon detector, and forward proton detector. The uranium/liquid-argon calorimeters and central muon detector, remaining from Run I, are discussed briefly. We also present the associated electronics, triggering, and data acquisition systems, along with the design and implementation of software specific to D0.

  12. Adaptation of an evaporative light-scattering detector to micro and capillary liquid chromatography and response assessment.

    PubMed

    Gaudin, Karen; Baillet, Arlette; Chaminade, Pierre

    2004-10-08

    A commercially available evaporative light-scattering detection (ELSD) system was adapted for micro and capillary LC. Therefore the various parameters involved in the droplet formation during the nebulization step in the ELSD system were studied. It was shown that the velocity term in the Nukiyama Tanasawa equation remains constant, leading to droplets of the same order of magnitude for narrow bore and capillary columns. Consequently, the ELSD modification was performed by decreasing the internal diameter of the effluent capillary tube in the nebulizer nozzle and by keeping its external diameter constant. Next, response curves for a conventional and the developed micro and capillary LC were compared as to investigate why a linear ELSD response is often obtained when used in micro or capillary LC. By splitting the flow rate post column, we showed that the nebulization process was not at the origin of the phenomenon. For ceramide III and tripalmitin, the response curves were found to be non-linear. However the curvature was less significant when the columns internal diameter decreased. Calculated particle size profiles for micro or capillary LC suggest that the particle entering the detection chamber are bigger than under conventional LC conditions. Last, triethylamine and formic acid were used to increase the response of the detector. The response enhancement, expected from previous studies, was established for the two lipids involved in this study.

  13. Fractionated (Martian) Noble Gases — EFA, Experiments and Meteorites

    NASA Astrophysics Data System (ADS)

    Schwenzer, S. P.; Barnes, G.; Bridges, J. C.; Bullock, M. A.; Chavez, C. L.; Filiberto, J.; Herrmann, S.; Hicks, L. J.; Kelley, S. P.; Miller, M. A.; Moore, J. M.; Ott, U.; Smith, H. D.; Steer, E. D.; Swindle, T. D.; Treiman, A. H.

    2016-08-01

    Noble gases are tracers for physical processes, including adsorption, dissolution and secondary mineral formation. We examine the Martian fractionated atmosphere through literature, terrestrial analogs and experiments.

  14. New applications of noble metal catalysts in hydrocracking

    SciTech Connect

    Mitchell, D.H.G.; Bertram, R.V.; Dencker, G.D.

    1995-09-01

    The paper explores how a noble metal hydrocracking catalyst functions stably in a hydrogen sulfide and ammonia environment and, in particular, how the physical positioning of the noble metal molecules affects catalyst performance. A commercial example, HC-28 catalyst in the Unicracking unit at Marathon Oil Refinery in Robinson, Illinois, demonstrates the success of the noble metal catalyst approach for naphtha production. In addition, a new Unicracking catalyst, HC-35, which uses a noble metal component to produce high-quality middle distillates, is introduced. The paper also shows how refiners may derive increased economic and operational benefits from their catalyst investment by using the latest developments in reactor internals design.

  15. Selective Growth of Noble Gases at Metal/Oxide Interface.

    PubMed

    Takahashi, Keisuke; Oka, Hiroshi; Ohnuki, Somei

    2016-02-17

    The locations and roles of noble gases at an oxide/metal interface in oxide dispersed metal are theoretically and experimentally investigated. Oxide dispersed metal consisting of FCC Fe and Y2Hf2O7 (Y2Ti2O7) is synthesized by mechanical alloying under a saturated Ar gas environment. Transmission electron microscopy and density functional theory observes the strain field at the interface of FCC Fe {111} and Y2Hf2O7 {111} whose physical origin emerges from surface reconstruction due to charge transfer. Noble gases are experimentally observed at the oxide (Y2Ti2O7) site and calculations reveal that the noble gases segregate the interface and grow toward the oxide site. In general, the interface is defined as the trapping site for noble gases; however, transmission electron microscopy and density functional theory found evidence which shows that noble gases grow toward the oxide, contrary to the generally held idea that the interface is the final trapping site for noble gases. Furthermore, calculations show that the inclusion of He/Ar hardens the oxide, suggesting that material fractures could begin from the noble gas bubble within the oxides. Thus, experimental and theoretical results demonstrate that noble gases grow from the interface toward the oxide and that oxides behave as a trapping site for noble gases.

  16. Inert electrode containing metal oxides, copper and noble metal

    DOEpatents

    Ray, Siba P.; Woods, Robert W.; Dawless, Robert K.; Hosler, Robert B.

    2000-01-01

    A cermet composite material is made by treating at an elevated temperature a mixture comprising a compound of iron and a compound of at least one other metal, together with an alloy or mixture of copper and a noble metal. The alloy or mixture preferably comprises particles having an interior portion containing more copper than noble metal and an exterior portion containing more noble metal than copper. The noble metal is preferably silver. The cermet composite material preferably includes alloy phase portions and a ceramic phase portion. At least part of the ceramic phase portion preferably has a spinel structure.

  17. Inert electrode containing metal oxides, copper and noble metal

    DOEpatents

    Ray, Siba P.; Woods, Robert W.; Dawless, Robert K.; Hosler, Robert B.

    2001-01-01

    A cermet composite material is made by treating at an elevated temperature a mixture comprising a compound of iron and a compound of at least one other metal, together with an alloy or mixture of copper and a noble metal. The alloy or mixture preferably comprises particles having an interior portion containing more copper than noble metal and an exterior portion containing more noble metal than copper. The noble metal is preferably silver. The cermet composite material preferably includes alloy phase portions and a ceramic phase portion. At least part of the ceramic phase portion preferably has a spinel structure.

  18. A new experimental procedure for determination of photoelectric efficiency of a NaI(Tl) detector used for nuclear medicine liquid waste monitoring with traceability to a reference standard radionuclide calibrator.

    PubMed

    Ceccatelli, A; Campanella, F; Ciofetta, G; Marracino, F M; Cannatà, V

    2010-02-01

    To determine photopeak efficiency for (99m)Tc of the NaI(Tl) detector used for liquid waste monitoring at the Nuclear Medicine Unit of IRCCS Paediatric Hospital Bambino Gesù in Rome, a specific experimental procedure, with traceability to primary standards, was developed. Working with the Italian National Institute for Occupational Prevention and Safety, two different calibration source geometries were employed and the detector response dependence on geometry was investigated. The large percentage difference (almost 40%) between the two efficiency values obtained showed that geometrical effects cannot be neglected.

  19. Determination of pesticides in sunflower seeds by high-performance liquid chromatography coupled with a diode array detector.

    PubMed

    Tuzimski, Tomasz; Rejczak, Tomasz

    2014-01-01

    The application of RP-HPLC with a diode array detector for identification and quantitative analysis of pesticides in sunflower seed samples is demonstrated. An HPLC procedure on C18 RP column has been developed for analysis of selected pesticides from different chemical groups: simazine, isoproturon, terbuthylazine, linuron, captan, terbutryn, procymidone, fenitrothion, clofentezine, and bromopropylate. We investigated the possibility of expanding the scope of the four analyte extraction procedures for isolation of pesticides from plant matrixes with high levels of lipids. The following procedures were tested: A, ultrasound-assisted solvent extraction (UAE) and SPE; B, dispersive-SPE (d-SPE); C, UAE and d-SPE; and D, UAE/SPE/d-SPE. Average recoveries from spiked samples at different concentrations in the range from 0.1 to 1.40 microg/g in the plant materials and the SDs for C18 cartridges and solvents by the proposed RP-HPLC-DAD method after the extraction procedures are also presented. The efficiency of procedures A-D was evaluated using real food samples from Hungary, Bulgaria, and Poland. The quantity of terbuthylazine determined was in the range of 7.1-12.7 ng/g (n = 6), whereas the quantity of procymidone determined was in the range of 3.7-5.7 ng/g (n = 3) in plant materials. The quantities of pesticides determined in sunflower seeds were below the maximum residue levels (excluding captan) established in the European Union legislation. The method was validated for precision and accuracy.

  20. The unification of psychology: a noble quest.

    PubMed

    Calhoun, Lawrence G

    2004-12-01

    Henriques' effort to develop a unified theory for psychology represents a noble quest (this issue). Even if the quest fails, the effort itself may produce benefits for psychology. This article focuses first on some general comments on the unified theory, with some suggestions about elements that seem desirable in the theory and some elements that may benefit from further elaboration. A specific application to the area of posttraumatic growth suggests the theory is capable of providing a framework for understanding specific areas of human psychology. Finally, the potential future of the unified theory is considered with a focus on its potential as a "useful mass movement" in psychology.

  1. Electron recombination in low-energy nuclear recoils tracks in liquid argon

    NASA Astrophysics Data System (ADS)

    Wojcik, M.

    2016-02-01

    This paper presents an analysis of electron-ion recombination processes in ionization tracks of recoiled atoms in liquid argon (LAr) detectors. The analysis is based on the results of computer simulations which use realistic models of electron transport and reactions. The calculations reproduce the recent experimental results of the ionization yield from 6.7 keV nuclear recoils in LAr. The statistical distribution of the number of electrons that escape recombination is found to deviate from the binomial distribution, and estimates of recombination fluctuations for nuclear recoils tracks are obtained. A study of the recombination kinetics shows that a significant part of electrons undergo very fast static recombination, an effect that may be responsible for the weak drift-field dependence of the ionization yield from nuclear recoils in some noble liquids. The obtained results can be useful in the search for hypothetical dark matter particles and in other studies that involve detection of recoiled nuclei.

  2. Rapid and simple method for the determination of emodin in tartary buckwheat (Fagopyrum tataricum) by high-performance liquid chromatography coupled to a diode array detector.

    PubMed

    Peng, Lian-Xin; Wang, Jing-Bo; Hu, Li-Xue; Zhao, Jiang-Lin; Xiang, Da-Bing; Zou, Liang; Zhao, Gang

    2013-01-30

    A simple and rapid method for determining emodin, an active factor presented in tartary buckwheat (Fagopyrum tataricum), by high-performance liquid chromatography coupled to a diode array detector (HPLC-DAD) has been developed. Emodin was separated from an extract of buckwheat on a Kromasil-ODS C(18) (250 mm × 4.6 mm × 5 μm) column. The separation is achieved within 15 min on the ODS column. Emodin can be quantified using an external standard method detecting at 436 nm. Good linearity is obtained with a correlation coefficient exceeding 0.9992. The limit of detection and the limit of quantification are 5.7 and 19 μg/L, respectively. This method shows good reproducibility for the quantification of the emodin with a relative standard deviation value of 4.3%. Under optimized extraction conditions, the recovery of emodin was calculated as >90%. The validated method is successfully applied to quantify the emodin in tartary buckwheat and its products.

  3. Qualitative and quantitative analysis of an alkaloid fraction from Piper longum L. using ultra-high performance liquid chromatography-diode array detector-electrospray ionization mass spectrometry.

    PubMed

    Li, Kuiyong; Fan, Yunpeng; Wang, Hui; Fu, Qing; Jin, Yu; Liang, Xinmiao

    2015-05-10

    In a previous research, an alkaloid fraction and 18 alkaloid compounds were prepared from Piper longum L. by series of purification process. In this paper, a qualitative and quantitative analysis method using ultra-high performance liquid chromatography-diode array detector-mass spectrometry (UHPLC-DAD-MS) was developed to evaluate the alkaloid fraction. Qualitative analysis of the alkaloid fraction was firstly completed by UHPLC-DAD method and 18 amide alkaloid compounds were identified. A further qualitative analysis of the alkaloid fraction was accomplished by UHPLC-MS/MS method. Another 25 amide alkaloids were identified according to their characteristic ions and neutral losses. At last, a quantitative method for the alkaloid fraction was established using four marker compounds including piperine, pipernonatine, guineensine and N-isobutyl-2E,4E-octadecadienamide. After the validation of this method, the contents of above four marker compounds in the alkaloid fraction were 57.5mg/g, 65.6mg/g, 17.7mg/g and 23.9mg/g, respectively. Moreover, the relative response factors of other three compounds to piperine were calculated. A comparative study between external standard quantification and relative response factor quantification proved no remarkable difference. UHPLC-DAD-MS method was demonstrated to be a powerful tool for the characterization of the alkaloid fraction from P. longum L. and the result proved that the quality of alkaloid fraction was efficiently improved after appropriate purification.

  4. Analysis of EU priority polycyclic aromatic hydrocarbons in food supplements using high performance liquid chromatography coupled to an ultraviolet, diode array or fluorescence detector.

    PubMed

    Danyi, Sophie; Brose, François; Brasseur, Catherine; Schneider, Yves-Jacques; Larondelle, Yvan; Pussemier, Luc; Robbens, Johan; De Saeger, Sarah; Maghuin-Rogister, Guy; Scippo, Marie-Louise

    2009-02-09

    High performance liquid chromatography coupled to an ultraviolet, diode array or fluorescence detector (HPLC/UV-FLD) has been used to set up a method to detect the 15(+1) EU priority polycyclic aromatic hydrocarbons (PAHs) in food supplements covering the categories of dried plants and plant extracts excluding oily products. A mini validation was performed and the following parameters have been determined: limit of detection, limit of quantification, precision, recovery and linearity. They were in close agreement with quality criteria described in the Commission Regulation (EC) No 333/2007 concerning the PAH benzo[a]pyrene in foodstuffs, except the not fluorescent cyclopenta[c,d]pyrene for which the UV detection leads to a higher limit of detection. Analysis of twenty commercial food supplements covering mainly the class of dried plants was performed to evaluate their PAHs contamination levels and to test the applicability of the method to various plant matrices. Fifty percent of analyzed samples showed concentration exceeding 2 microgkg(-1) for one or more PAHs.

  5. Simple, cost-effective and sensitive liquid chromatography diode array detector method for simultaneous determination of eight sulfonylurea herbicides in soya milk samples.

    PubMed

    Rejczak, Tomasz; Tuzimski, Tomasz

    2016-11-18

    In this study authors propose a simple, cost-effective and sensitive liquid chromatography diode array detector (HPLC-DAD) method for the simultaneous determination of eight sulfonylurea herbicides (oxasulfuron, metsulfuron-methyl, triasulfuron, rimsulfuron, chlorsulfuron, mesosulfuron-methyl, amidosulfuron and bensulfuron-methyl) in soya milk samples. QuEChERS-based extraction procedure presents good performance for all of the analytes with recoveries in the range of 61-108% and relative standard deviations (RSD%) less than 15%. No significant matrix effect was observed thanks to application of effective zirconium-dioxide based sorbent (Z-Sep). Method LOQs for all investigated analytes were set at satisfactory low value of 10ngmL(-1) of food product. The procedure was evaluated in terms of natural samples analysis. Chlorsulfuron was determined at concentration of 14.2ngmL(-1) of soya milk product, which was qualitatively confirmed via LC coupled with tandem mass spectrometry (LC-MS/MS). The most important steps of procedure optimization are presented.

  6. Identification and chemical profiling of monacolins in red yeast rice using high-performance liquid chromatography with photodiode array detector and mass spectrometry.

    PubMed

    Li, Yong-Guo; Zhang, Fang; Wang, Zheng-Tao; Hu, Zhi-Bi

    2004-09-03

    Monascus purpureus-fermented rice (red yeast rice) was one of the food supplements that had the ability of lowering the blood-lipid levels, and monacolins have been proved to be main active constituents. In total 14 monacolin compounds such as monacolin K (mevinolin), J, L, M, X, and their hydroxy acid form, as well as dehydromonacolin K, dihydromonacolin L, compactin, 3alpha-hydroxy-3,5-dihydromonacolin L, etc. were identified in red yeast rice, using high-performance liquid chromatography with photodiode array detector and tandem mass spectrometry. A chemical fingerprint profiling method to display bioactive monacolins in red yeast rice was established and could be used for the quality control of the target material and its related products. Ten finish products labeled as red yeast rice from different manufacturers in marketing were traced using the chromatographic chemical profiling method, and the results show that only two of them were similar while the other eight were significantly different from the reference red yeast rice. All of these materials including raw material powder and finished products available were quantified and the contents of monacolins were calculated with reference of monacolin K (mevinolin) as the standard.

  7. Simultaneous determination of ten bioactive compaounds from the roots of Cynanchum paniculatum by using high performance liquid chromatography coupled-diode array detector

    PubMed Central

    Weon, Jin Bae; Lee, Bohyoung; Yun, Bo-Ra; Lee, Jiwoo; Ma, Choong Je

    2012-01-01

    Background: Cynanchum paniculatum Kitagawa belongs to Asclepiadaceae and was used in traditional medicine to invigorate blood, alleviate edema, relieve pain, and relieve toxicity for a long time. Objective: A novel and reliable high performance liquid chromatography coupled with diode array detector method has been established for simultaneous determination of 10 bioactive compounds isolated from Cynanchum paniculatum Kitagawa, one of the herbal medicines. Materials and Methods: The chromatography analysis was performed on a SHISEIDO C18 column (S-5 μm, 4.6 mm I.D. × 250 mm) at 35°C with a gradient elution of acetonitrile and water at a flow rate of 1ml/min and UV detection at 210, 230, and 280 nm. Results: The method was validated for linearity, precision, and accuracy. All calibration curves showed good linear regression (r2 > 0.9996). Limits of detection (LOD) and limits of quantification (LOQ) fell in the ranges 0.01 - 0.28 μg/ml and 0.04 - 0.83 μg/ml, respectively. The relative standard deviation (RSD) of the intra- and inter- day test, precision test were within 1.92% and 2.43%, respectively. The mean recovery of all ranged from 92.82 to 107.96% with RSD values 0.12 - 2.18%. Conclusion: The results of validation appeared that this established method was very accurate and stabilized for the quantification of 10 bioactive compounds isolated from C. paniculatum. PMID:23060698

  8. Search for 2νββ decay of Xe136 to the 01+ excited state of Ba136 with the EXO-200 liquid xenon detector

    DOE PAGES

    Albert, J. B.; Auty, D. J.; Barbeau, P. S.; ...

    2016-03-08

    EXO-200 is a single phase liquid xenon detector designed to search for neutrinoless ββ decay of 136Xe to the ground state of 136Ba. We report here on a search for the two-neutrino ββ decay of 136Xe to the first 0+ excited state, 0+1, of Ba136 based on a 100 kg yr exposure of 136Xe. Using a specialized analysis employing a machine learning algorithm, we obtain a 90% CL half-life sensitivity of 1.7×1024 yr. We find no statistically significant evidence for the 2νββ decay to the excited state resulting in a lower limit of T2ν1/2 (0+ → 0+1) > 6.9 ×1023more » yr at 90% CL. In conclusion, this observed limit is consistent with the estimated half-life of 2.5×1025 yr.« less

  9. Rapid and sensitive determination of benzo[a]pyrene in black ginseng using fluorescence detector and high performance liquid chromatography-tandem mass spectrometry

    NASA Astrophysics Data System (ADS)

    Cho, Hyun-jeong; Kim, Hye-jin; Son, Byeong-cheol; Jo, Dong-keun; Cho, Byung-lim

    2013-05-01

    Black ginseng is produced by steaming a ginseng root followed by drying repeatedly 9 times during the process and it is changed to be black color, so it is known that a black ginseng has more contents of saponins than red ginseng. However a fake black ginseng which is produced to be black color at high temperature in a short period of time generate carcinogenic benzo[a]pyrene(BaP) through the process. In this year, maximum residue level(MRL) for BaP was established to 2 ug/kg in black ginseng and more sensitive method was developed to quantitatively analyze the BaP by high performance liquid chromatography (HPLC) coupling with florescence detector and tandem mass spectrometry (atmospheric pressure chemical ionization-MS/MS). Chromatographic separation was performed on a Supelcosil™ LC-PAH column (3 μm, 3 mm x 50 mm). Mobile phase A was water and mobile phase B was acetonitrile. BaP was exactly separated from other 15 polycyclic aromatic hydrocarbons (PAHs) which have been selected as priority pollutants by the US Environmental Protection Agency (EPA). Linearity of detection was in the range of 0.2~20 μg/kg and limit of detection (LOD) for BaP was lower than 0.1 μg/kg, limit of quantification (LOQ) was 0.2 μg/kg. The recovery of Bap was 92.54%+/-6.3% in black ginseng.

  10. Analysis of oil-biodiesel samples by high performance liquid chromatography using the normal phase column of new generation and the evaporative light scattering detector.

    PubMed

    Fedosov, Sergey N; Fernandes, Natalia A; Firdaus, Mohd Y

    2014-01-24

    Conversion of vegetable oil to biodiesel is usually monitored by gas chromatography. This is not always convenient because of (i) an elaborate derivatization of the samples; (ii) inhibition of this process by methanol and water; (iii) low stability of the derivatives under storage. HPLC methods are apparently more convenient, but none of the described variants had won a wide recognition so far. This can be ascribed to the problems of reproducibility (in the case of normal phase chromatography) and limited separation of some analytes (in the case of reverse phase chromatography). Here we report an HPLC procedure suitable for separation of biodiesel, free fatty acids, glycerides, glycerol and lecithin. The normal phase column of new generation (Poroshell 120 HILIC) and the novel gradient were used. The method was tested on both the artificial mixtures and the crude reaction samples. Elution of the analytes was monitored by an evaporative light scattering detector. This method is usually confined to a very limited range of masses, where only a part of the complex calibration curve is used. We have analyzed the light scattering signal within a very broad range of masses, whereupon the calibration curves were produced. The data were approximated by the appropriate equations used afterward to recalculate the signal to the mass in a convenient way. An experimental conversion of rapeseed oil to biodiesel was performed by a liquid lipase formulation. This process was monitored by HPLC to illustrate advantages of the suggested registration method.

  11. Fingerprint analysis of Hibiscus mutabilis L. leaves based on ultra performance liquid chromatography with photodiode array detector combined with similarity analysis and hierarchical clustering analysis methods

    PubMed Central

    Liang, Xianrui; Ma, Meiling; Su, Weike

    2013-01-01

    Background: A method for chemical fingerprint analysis of Hibiscus mutabilis L. leaves was developed based on ultra performance liquid chromatography with photodiode array detector (UPLC-PAD) combined with similarity analysis (SA) and hierarchical clustering analysis (HCA). Materials and Methods: 10 batches of Hibiscus mutabilis L. leaves samples were collected from different regions of China. UPLC-PAD was employed to collect chemical fingerprints of Hibiscus mutabilis L. leaves. Results: The relative standard deviations (RSDs) of the relative retention times (RRT) and relative peak areas (RPA) of 10 characteristic peaks (one of them was identified as rutin) in precision, repeatability and stability test were less than 3%, and the method of fingerprint analysis was validated to be suitable for the Hibiscus mutabilis L. leaves. Conclusions: The chromatographic fingerprints showed abundant diversity of chemical constituents qualitatively in the 10 batches of Hibiscus mutabilis L. leaves samples from different locations by similarity analysis on basis of calculating the correlation coefficients between each two fingerprints. Moreover, the HCA method clustered the samples into four classes, and the HCA dendrogram showed the close or distant relations among the 10 samples, which was consistent to the SA result to some extent. PMID:23930008

  12. Quantification of polycyclic aromatic hydrocarbons in toasted guaraná (Paullinia cupana) by high-performance liquid chromatography with a fluorescence detector.

    PubMed

    Veiga, L L A; Amorim, H; Moraes, J; Silva, M C; Raices, R S L; Quiterio, S L

    2014-01-01

    Samples of toasted guaraná seeds with husk from Maués (Amazônia) and ten samples of different brands of guaraná powder produced in different parts of Brazil were analysed in this work, aiming to identify and quantify 16 PAHs. The samples were analysed by high-performance liquid chromatography equipped with fluorescence and UV-Vis detectors. Naphthalene was identified and quantified in the guaraná samples (0.13 and 0.78 μg kg(-1)) and both naphthalene and phenanthrene were found in two commercial guaraná powder samples (0.36-1.54 and 0.03-0.06 μg kg(-1), respectively). Considering that the average daily intake of guaraná powder is equivalent to 10 g, it can be seen that guaraná powder contains less PAHs than the limit established in European legislation for other kinds of food (CE 835/2011), that is, around 0.20 μg kg(-1) of PAHs.

  13. Fullerenes and Noble Gases in the Murchison and Allende Meteorites

    NASA Technical Reports Server (NTRS)

    Becker, Luann; Poreda, Robert J.; Bunch, Ted E.

    2000-01-01

    In this work we report the detection of fullerenes (C60 to C250) in the Murchison and Allende meteorites. By exploiting the unique ability of these molecules to trap noble gases, we have determined that fullerene is indeed a new carrier phase for noble gases in meteorites.

  14. The Thermochemical Stability of Ionic Noble Gas Compounds.

    ERIC Educational Resources Information Center

    Purser, Gordon H.

    1988-01-01

    Presents calculations that suggest stoichiometric, ionic, and noble gas-metal compounds may be stable. Bases calculations on estimated values of electron affinity, anionic radius for the noble gases and for the Born exponents of resulting crystals. Suggests the desirability of experiments designed to prepare compounds containing anionic,…

  15. The Noble Gases in A-Level Chemistry.

    ERIC Educational Resources Information Center

    Marchant, G. W.

    1983-01-01

    Suggests two methods of developing the study of the noble gases: first, the discovery of the elements and recent discovery of xenon show the human face of chemistry (historical development); second, the properties of noble gas compounds (particularly xenon) can be used to test the framework of conventional chemistry. (Author/JM)

  16. Using noble gases measured in spring discharge to trace hydrothermal processes in the Norris Geyser Basin, Yellowstone National Park, U.S.A.

    USGS Publications Warehouse

    Gardner, W.P.; Susong, D.D.; Solomon, D.K.; Heasler, H.P.

    2010-01-01

    Dissolved noble gas concentrations in springs are used to investigate boiling of hydrothermal water and mixing of hydrothermal and shallow cool water in the Norris Geyser Basin area. Noble gas concentrations in water are modeled for single stage and continuous steam removal. Limitations on boiling using noble gas concentrations are then used to estimate the isotopic effect of boiling on hydrothermal water, allowing the isotopic composition of the parent hydrothermal water to be determined from that measured in spring. In neutral chloride springs of the Norris Geyser Basin, steam loss since the last addition of noble gas charged water is less than 30% of the total hydrothermal discharge, which results in an isotopic shift due to boiling of ?? 2.5% ??D. Noble gas concentrations in water rapidly and predictably change in dual phase systems, making them invaluable tracers of gas-liquid interaction in hydrothermal systems. By combining traditional tracers of hydrothermal flow such as deuterium with dissolved noble gas measurements, more complex hydrothermal processes can be interpreted. ?? 2010 Elsevier B.V.

  17. A preliminary report on noble gas isotope analyses using the Helix-MC multi-collector mass spectrometer

    NASA Astrophysics Data System (ADS)

    Honda, M.; Zhang, X.; Phillips, D.; Szczepanski, S.; Deerberg, M.; Hamilton, D.; Krummen, M.; Schwieters, J.

    2013-12-01

    Analyses of noble gas isotopes by multi-collector mass spectrometry substantially improve measurement precision and accuracy, with the potential to revolutionise applications to cosmo-geo-sciences. The Helix-MC noble gas mass spectrometer manufactured by Thermo-Fisher is a 350mm, 120 degree extended geometry, high resolution, multi-collector mass spectrometer for the simultaneous analysis of noble gas isotopes. The detector array includes a fixed axial (Ax) detector, 2 adjustable high mass (H1 and H2) detectors and 2 adjustable low mass (L1 and L2) detectors. Each detector is equipped with a Faraday/ion counting multiplier CFM (Combined Faraday and CDD Multiplier) detector. Mass resolution and mass resolving power on the H2, Ax and L2 detectors of the Helix-MC installed at the Australian National University (ANU) are approximately 1,800 and 8,000, respectively. The noble gas handling system on-line to the Helix-MC consists of: (1) a resistively-heated, double-vacuum, tantalum furnace system, (2) air actuated vacuum crusher, (3) Photon-Machines diode laser heating system, (4) Janis He cryogenic trap assembly, (5) gas purification system and (6) standard gas pipette tanks, which are totally automated and controlled by the Qtegra software platform developed by Thermo-Fisher. Eleven repeat measurements of atmospheric Ar using the H2 Faraday (1E11 ohm resistor) and L2 CDD collectors on the Helix-MC, yield a mean 40Ar/36Ar ratio of 322.09 +- 0.28 (0.089%) with a 4,700 fA 40Ar beam current. This result compares favourably with the precision achieved by the Argus VI at the University of Melbourne (318.12 +- 0.17; 0.052%; n = 10) with a similar beam size of 4,200 fA. The high mass resolution of the L2 collector permits complete separation of the 36Ar and interfering 3 x 12C (required mass resolution (MR) of 1,100) and partial separation of H35Cl (MR = 3,900). This capability enables evaluation of the significance of Ar isotopic interferences related to the correction of

  18. Multidiffusion mechanisms for noble gases (He, Ne, Ar) in silicate glasses and melts in the transition temperature domain: Implications for glass polymerization

    NASA Astrophysics Data System (ADS)

    Amalberti, Julien; Burnard, Pete; Laporte, Didier; Tissandier, Laurent; Neuville, Daniel R.

    2016-01-01

    Noble gases are ideal probes to study the structure of silicate glasses and melts as the modifications of the silicate network induced by the incorporation of noble gases are negligible. In addition, there are systematic variations in noble gas atomic radii and several noble gas isotopes with which the influence of the network itself on diffusion may be investigated. Noble gases are therefore ideally suited to constrain the time scales of magma degassing and cooling. In order to document noble gas diffusion behavior in silicate glass, we measured the diffusivities of three noble gases (4He, 20Ne and 40Ar) and the isotopic diffusivities of two Ar isotopes (36Ar and 40Ar) in two synthetic basaltic glasses (G1 and G2; 20Ne and 36Ar were only measured in sample G1). These new diffusion results are used to re-interpret time scales of the acquisition of fractionated atmospheric noble gas signatures in pumices. The noble gas bearing glasses were synthesized by exposing the liquids to high noble gas partial pressures at high temperature and pressure (1750-1770 K and 1.2 GPa) in a piston-cylinder apparatus. Diffusivities were measured by step heating the glasses between 423 and 1198 K and measuring the fraction of gas released at each temperature step by noble gas mass spectrometry. In addition we measured the viscosity of G1 between 996 and 1072 K in order to determine the precise glass transition temperature and to estimate network relaxation time scales. The results indicate that, to a first order, that the smaller the size of the diffusing atom, the greater its diffusivity at a given temperature: D(He) > D(Ne) > D(Ar) at constant T. Significantly, the diffusivities of the noble gases in the glasses investigated do not display simple Arrhenian behavior: there are well-defined departures from Arrhenian behavior which occur at lower temperatures for He than for Ne or Ar. We propose that the non-Arrhenian behavior of noble gases can be explained by structural modifications

  19. Mass fractionation of noble gases in synthetic methane hydrate: Implications for naturally occurring gas hydrate dissociation

    USGS Publications Warehouse

    Hunt, Andrew G.; Stern, Laura; Pohlman, John W.; Ruppel, Carolyn; Moscati, Richard J.; Landis, Gary P.

    2013-01-01

    As a consequence of contemporary or longer term (since 15 ka) climate warming, gas hydrates in some settings may presently be dissociating and releasing methane and other gases to the ocean-atmosphere system. A key challenge in assessing the impact of dissociating gas hydrates on global atmospheric methane is the lack of a technique able to distinguish between methane recently released from gas hydrates and methane emitted from leaky thermogenic reservoirs, shallow sediments (some newly thawed), coal beds, and other sources. Carbon and deuterium stable isotopic fractionation during methane formation provides a first-order constraint on the processes (microbial or thermogenic) of methane generation. However, because gas hydrate formation and dissociation do not cause significant isotopic fractionation, a stable isotope-based hydrate-source determination is not possible. Here, we investigate patterns of mass-dependent noble gas fractionation within the gas hydrate lattice to fingerprint methane released from gas hydrates. Starting with synthetic gas hydrate formed under laboratory conditions, we document complex noble gas fractionation patterns in the gases liberated during dissociation and explore the effects of aging and storage (e.g., in liquid nitrogen), as well as sampling and preservation procedures. The laboratory results confirm a unique noble gas fractionation pattern for gas hydrates, one that shows promise in evaluating modern natural gas seeps for a signature associated with gas hydrate dissociation.

  20. Noble gas storage and delivery system for ion propulsion

    NASA Technical Reports Server (NTRS)

    Back, Dwight Douglas (Inventor); Ramos, Charlie (Inventor)

    2001-01-01

    A method and system for storing and delivering a noble gas for an ion propulsion system where an adsorbent bearing a noble gas is heated within a storage vessel to desorb the noble gas which is then flowed through a pressure reduction device to a thruster assembly. The pressure and flow is controlled using a flow restrictor and low wattage heater which heats an adsorbent bed containing the noble gas propellant at low pressures. Flow rates of 5-60 sccm can be controlled to within about 0.5% or less and the required input power is generally less than 50 W. This noble gas storage and delivery system and method can be used for earth orbit satellites, and lunar or planetary space missions.

  1. Simultaneous qualitative and quantitative determination of phenolic compounds in Aloe barbadensis Mill by liquid chromatography-mass spectrometry-ion trap-time-of-flight and high performance liquid chromatography-diode array detector.

    PubMed

    Wu, Xiaofang; Ding, Wenjing; Zhong, Jiasheng; Wan, Jinzhi; Xie, Zhiyong

    2013-06-01

    An effective and comprehensive method was developed for the simultaneous analysis of phenolic compounds in the dried exudate of Aloe barbadensis Mill by liquid chromatography-mass spectrometry-ion trap-time-of-flight (LCMS-IT-TOF) and high performance liquid chromatography-diode array detector (HPLC-DAD). Qualitative analysis of all the compounds presented in A. barbadensis Mill was performed on LCMS-IT-TOF, and the diagnostic fragmentation patterns of different types of phenolic compounds (chromones, phenyl pyrones, naphthalene derivative, anthrones and anthraquinones) were discussed on the basis of ESI-IT-TOF MS of components in A. barbadensis Mill and eleven authentic standards. Under the optimal HPLC-DAD chromatographic conditions, quantification of 11 typical phenolic compounds in 15 batches of A. barbadensis Mill was achieved on an Agilent TC-C18 column using gradient elution with a solvent system of methanol and water at a flow rate of 1.0mLmin(-1) and detected at 230nm. All calibration curves exhibited good linear relationship (r(2)>0.9991). The relative standard deviation values for intraday precision were less than 2% with accuracies between 98.21% and 104.57%. The recoveries of the eleven analytes ranged from 97.53 to 105.00% with RSDs less than 2%. This is the first simultaneous characterization and quantitative determination of multiple phenolic compounds in A. barbadensis Mill from locally grown cultivars in China by LCMS-IT-TOF and HPLC-DAD, which can be applied to standardize the quality of A. barbadensis Mill and the future design of nutraceutical and cosmetic preparations.

  2. Optimal optoacoustic detector design

    NASA Technical Reports Server (NTRS)

    Rosengren, L.-G.

    1975-01-01

    Optoacoustic detectors are used to measure pressure changes occurring in enclosed gases, liquids, or solids being excited by intensity or frequency modulated electromagnetic radiation. Radiation absorption spectra, collisional relaxation rates, substance compositions, and reactions can be determined from the time behavior of these pressure changes. Very successful measurements of gaseous air pollutants have, for instance, been performed by using detectors of this type together with different lasers. The measuring instrument consisting of radiation source, modulator, optoacoustic detector, etc. is often called spectrophone. In the present paper, a thorough optoacoustic detector optimization analysis based upon a review of its theory of operation is introduced. New quantitative rules and suggestions explaining how to design detectors with maximal pressure responsivity and over-all sensitivity and minimal background signal are presented.

  3. Determination of Ruscogenin in Ophiopogonis Radix by High-performance Liquid Chromatography-evaporative Light Scattering Detector Coupled with Hierarchical Clustering Analysis

    PubMed Central

    Liu, Chun-Hua; Li, Ming; Feng, Ya-Qian; Hu, Yuan-Jia; Yu, Bo-Yang; Qi, Jin

    2016-01-01

    Background: Ophiopogonis Radix is a famous traditional Chinese medicine. It is necessary to establish a suitable quality control methods of Ophiopogonis Radix. Objective: To investigate the quality control methods of Ophiopogonis Radix by high-performance liquid chromatography (HPLC) coupled with evaporative light scattering detector (ELSD). Materials and Methods: A rapid and simple method, HPLC coupled with ELSD, was applied to determinate ruscogenin in 35 batches of Ophiopogenis Radix samples. Orthogonal tests and single factor explorations were used to optimize the extraction condition of ruscogenin. The content of ruscogenin in different origin was further analyzed by hierarchical clustering analysis (HCA). Results: The ruscogenin was successfully determined by HPLC-ELSD with a two-phase solvent system composed of methanol-water (88:12) at a flow rate 1.0 ml/min, column temperature maintained at 25°C, detector draft tube temperature at 42.2°C, nebulizer gas flow rate at 1.4 L/min, and the gain at 8. The result showed the good linearity of ruscogenin in the range of 40.20–804.00 μg/ml (R2 = 0.9996). Average of recovery was 101.3% (relative standard deviation = 1.59%). A significant difference of ruscogenin content was shown among 35 batches of Ophiopogenis Radix from different origin, varied from 0.0035% to 0.0240%. HCA based on the content of ruscogenin indicated that Ophiopogonis Radix in different origin was mainly divided into two clusters. Conclusion: This simple, rapid, low-cost, and reliable HPLC-ELSD method could be suitable for measurement of ruscogenin content rations and quality control of Ophiopogonis Radix. SUMMARY Ophiopogonis Radix is an important Traditional Chinese Medicine (TCM) to treat and prevent cardiovascular diseases and acute or chronic inflammation for thousands of years. Steroidal saponins were known as the dominant active components for their significant cardiovascular activity, and the most steroid sapogenin of them is

  4. 3-dimensionally integrated photo-detector for neutrino physics and beyond

    NASA Astrophysics Data System (ADS)

    Retiere, Fabrice

    2016-09-01

    Silicon photo-multipliers (SiPMs) are a promising solution for the detection of scintillation light of liquid Xenon and Argon in applications requiring minimum radioactivity content such as neutrinoless double beta decay. The nEXO experiment in particular is planning to use SiPM planes covering 5 m2 for the detection of the light emitted within 5tons of liquid Xenon. The 3-dimensionally digital integrated SiPMs (3DdSiPMs) is an emerging technology that if successful would challenge the analog SiPM technology. Indeed, by combining separate photo-detector and electronics chips within a single package, 3DdSiPM achieve excellent performances for photon counting and time stamping, while dissipating minimum power. Being mostly based on high purity silicon chips, 3DdSiPMs are also expected to achieve excellent radiopurity.The development of 3DdSiPMs for applications in liquid Xenon is expected to progress rapidly by altering the design of the first successful chip assembly developed for medical imaging, focusing on minimizing power dissipation and large area (> cm2) scaling. In this talk we will describe the 3DdSiPM concept a solution for ``light to bit conversion'' within a single package and show how it may revolutionize light detection in noble-gas liquids and beyond.

  5. Ionization and Positronium Formation in Noble Gases

    NASA Astrophysics Data System (ADS)

    Marler, J. P.; Sullivan, J. P.; Surko, C. M.

    2006-11-01

    This paper reviews key results of our recent study [Marler et al., Phys. Rev. A 71, 022701 (2005)] of direct ionization and positronium formation in the noble gases from the thresholds for these processes to 90 eV. Results for argon and xenon are emphasized. The original study also reports similar results for neon and krypton. The experiment uses a cold, trap-based positron beam and scattering in a strong magnetic field to make absolute cross section measurements. Comparison with a detailed set of previous measurements yields reasonably good absolute agreement. A third, independent analysis was used to resolve the remaining discrepancies to a < 5% level in argon, krypton and xenon. Key aspects of the work, comparison with available theory, and open questions for future research are discussed.

  6. Ionization and positronium formation in noble gases

    SciTech Connect

    Marler, J.P.; Sullivan, J.P.; Surko, C.M.

    2005-02-01

    Absolute measurements are presented for the positron-impact cross sections for direct ionization and positronium formation of noble gas atoms in the range of energies from threshold to 90 eV. The experiment uses a cold, trap-based positron beam and the technique of studying positron scattering in a strong magnetic field. The current data show generally good, quantitative agreement with previous measurements taken using a qualitatively different method. However, significant differences in the cross sections for both direct ionization and positronium formation are also observed. An analysis is presented that yields another, independent measurement of the direct ionization and positronium formation cross sections that is in agreement with the present, direct measurements to within {+-}10% for argon, krypton, and xenon. Comparison with available theoretical predictions yields good quantitative agreement for direct ionization cross sections, and qualitative agreement in the case of positronium formation.

  7. Noble Metal Nanoparticles Applications in Cancer

    PubMed Central

    Conde, João; Doria, Gonçalo; Baptista, Pedro

    2012-01-01

    Nanotechnology has prompted new and improved materials for biomedical applications with particular emphasis in therapy and diagnostics. Special interest has been directed at providing enhanced molecular therapeutics for cancer, where conventional approaches do not effectively differentiate between cancerous and normal cells; that is, they lack specificity. This normally causes systemic toxicity and severe and adverse side effects with concomitant loss of quality of life. Because of their small size, nanoparticles can readily interact with biomolecules both at surface and inside cells, yielding better signals and target specificity for diagnostics and therapeutics. This way, a variety of nanoparticles with the possibility of diversified modification with biomolecules have been investigated for biomedical applications including their use in highly sensitive imaging assays, thermal ablation, and radiotherapy enhancement as well as drug and gene delivery and silencing. Here, we review the available noble metal nanoparticles for cancer therapy, with particular focus on those already being translated into clinical settings. PMID:22007307

  8. Biomedical imaging with hyperpolarized noble gases

    NASA Astrophysics Data System (ADS)

    Ruppert, Kai

    2014-11-01

    Hyperpolarized noble gases (HNGs), polarized to approximately 50% or higher, have led to major advances in magnetic resonance (MR) imaging of porous structures and air-filled cavities in human subjects, particularly the lung. By boosting the available signal to a level about 100 000 times higher than that at thermal equilibrium, air spaces that would otherwise appear as signal voids in an MR image can be revealed for structural and functional assessments. This review discusses how HNG MR imaging differs from conventional proton MR imaging, how MR pulse sequence design is affected and how the properties of gas imaging can be exploited to obtain hitherto inaccessible information in humans and animals. Current and possible future imaging techniques, and their application in the assessment of normal lung function as well as certain lung diseases, are described.

  9. Sir William Ramsay and the noble gases.

    PubMed

    Davies, Alwyn G

    2012-01-01

    Sir William Ramsay was one of the world's leading scientists at the end of the 19th century, and in a spectacular period of research between 1894 and 1898, he discovered five new elements. These were the noble gases, helium, neon, argon, krypton, and xenon; they added a whole new group to the Periodic Table of the elements, and provided the keystone to our understanding of the electronic structure of atoms, and the way those electrons bind the atoms together into molecules. For this work he was awarded the Nobel Prize in Chemistry in 1904, the first such prize to come to a British subject. He was also a man of great charm, a good linguist, and a composer and performer of music, poetry and song. This review will trace his career, describe his character and give and account of the chemistry which led to the award of the Nobel Prize.

  10. Atomic Layer Deposition Route To Tailor Nanoalloys of Noble and Non-noble Metals.

    PubMed

    Ramachandran, Ranjith K; Dendooven, Jolien; Filez, Matthias; Galvita, Vladimir V; Poelman, Hilde; Solano, Eduardo; Minjauw, Matthias M; Devloo-Casier, Kilian; Fonda, Emiliano; Hermida-Merino, Daniel; Bras, Wim; Marin, Guy B; Detavernier, Christophe

    2016-09-27

    Since their early discovery, bimetallic nanoparticles have revolutionized various fields, including nanomagnetism and optics as well as heterogeneous catalysis. Knowledge buildup in the past decades has witnessed that the nanoparticle size and composition strongly impact the nanoparticle's properties and performance. Yet, conventional synthesis strategies lack proper control over the nanoparticle morphology and composition. Recently, atomically precise synthesis of bimetallic nanoparticles has been achieved by atomic layer deposition (ALD), alleviating particle size and compositional nonuniformities. However, this bimetal ALD strategy applies to noble metals only, a small niche within the extensive class of bimetallic alloys. We report an ALD-based approach for the tailored synthesis of bimetallic nanoparticles containing both noble and non-noble metals, here exemplified for Pt-In. First, a Pt/In2O3 bilayer is deposited by ALD, yielding precisely defined Pt-In nanoparticles after high-temperature H2 reduction. The nanoparticles' In content can be accurately controlled over the whole compositional range, and the particle size can be tuned from micrometers down to the nanometer scale. The size and compositional flexibility provided by this ALD-approach will trigger the fabrication of fully tailored bimetallic nanomaterials, including superior nanocatalysts.

  11. Gas bubble detector

    NASA Technical Reports Server (NTRS)

    Mount, Bruce E. (Inventor); Burchfield, David E. (Inventor); Hagey, John M. (Inventor)

    1995-01-01

    A gas bubble detector having a modulated IR source focused through a bandpass filter onto a venturi, formed in a sample tube, to illuminate the venturi with modulated filtered IR to detect the presence of gas bubbles as small as 0.01 cm or about 0.004 in diameter in liquid flowing through the venturi. Means are provided to determine the size of any detected bubble and to provide an alarm in the absence of liquid in the sample tube.

  12. Intelligent peak deconvolution through in-depth study of the data matrix from liquid chromatography coupled with a photo-diode array detector applied to pharmaceutical analysis.

    PubMed

    Arase, Shuntaro; Horie, Kanta; Kato, Takashi; Noda, Akira; Mito, Yasuhiro; Takahashi, Masatoshi; Yanagisawa, Toshinobu

    2016-10-21

    Multivariate curve resolution-alternating least squares (MCR-ALS) method was investigated for its potential to accelerate pharmaceutical research and development. The fast and efficient separation of complex mixtures consisting of multiple components, including impurities as well as major drug substances, remains a challenging application for liquid chromatography in the field of pharmaceutical analysis. In this paper we suggest an integrated analysis algorithm functioning on a matrix of data generated from HPLC coupled with photo-diode array detector (HPLC-PDA) and consisting of the mathematical program for the developed multivariate curve resolution method using an expectation maximization (EM) algorithm with a bidirectional exponentially modified Gaussian (BEMG) model function as a constraint for chromatograms and numerous PDA spectra aligned with time axis. The algorithm provided less than ±1.0% error between true and separated peak area values at resolution (Rs) of 0.6 using simulation data for a three-component mixture with an elution order of a/b/c with similarity (a/b)=0.8410, (b/c)=0.9123 and (a/c)=0.9809 of spectra at peak apex. This software concept provides fast and robust separation analysis even when method development efforts fail to achieve complete separation of the target peaks. Additionally, this approach is potentially applicable to peak deconvolution, allowing quantitative analysis of co-eluted compounds having exactly the same molecular weight. This is complementary to the use of LC-MS to perform quantitative analysis on co-eluted compounds using selected ions to differentiate the proportion of response attributable to each compound.

  13. Development and validation of an high-performance liquid chromatography-diode array detector method for the simultaneous determination of six phenolic compounds in abnormal savda munziq decoction

    PubMed Central

    Tian, Shuge; Liu, Wenxian; Liu, Feng; Zhang, Xuejia; Upur, Halmuart

    2015-01-01

    Aims: Given the high-effectiveness and low-toxicity of abnormal savda munziq (ASMQ), its herbal formulation has long been used in traditional Uyghur medicine to treat complex diseases, such as cancer, diabetes, and cardiovascular diseases. Settings and Design: ASMQ decoction by reversed-phase high-performance liquid chromatography coupled with a diode array detector was successfully developed for the simultaneous quality assessment of gallic acid, protocatechuic acid, caffeic acid, rutin, rosmarinic acid, and luteolin. The six phenolic compounds were separated on an Agilent TC-C18 reversed-phase analytical column (4.6 × 250 mm, 5 μm) by gradient elution using 0.3% aqueous formic acid (v/v) and 0.3% methanol formic acid (v/v) at 1.0 mL/min. Materials and Methods: The plant material was separately ground and mixed at the following ratios (10): Cordia dichotoma (10.6), Anchusa italic (10.6), Euphorbia humifusa (4.9), Adiantum capillus-veneris (4.9), Ziziphus jujube (4.9), Glycyrrhiza uralensis (7.1), Foeniculum vulgare (4.9), Lavandula angustifolia (4.9), Dracocephalum moldavica L. (4.9), and Alhagi pseudoalhagi (42.3). Statistical Analysis Used: The precisions of all six compounds were <0.60%, and the average recoveries ranged from 99.39% to 104.85%. Highly significant linear correlations were found between component concentrations and specific chromatographic peak areas (R2 > 0.999). Results: The proposed method was successfully applied to determine the levels of six active components in ASMQ. Conclusions: Given the simplicity, precision, specificity, and sensitivity of the method, it can be utilized as a quality control approach to simultaneously determining the six phenolic compounds in AMSQ. PMID:25709227

  14. Antimicrobial activity of Marcetia DC species (Melastomataceae) and analysis of its flavonoids by reverse phase-high performance liquid chromatography coupled-diode array detector

    PubMed Central

    Leite, Tonny Cley Campos; de Sena, Amanda Reges; dos Santos Silva, Tânia Regina; dos Santos, Andrea Karla Almeida; Uetanabaro, Ana Paula Trovatti; Branco, Alexsandro

    2012-01-01

    Background: Marcetia genera currently comprises 29 species, with approximately 90% inhabiting Bahia (Brazil), and most are endemic to the highlands of the Chapada Diamantina (Bahia). Among the species, only M. taxifolia (A.St.-Hil.) DC. populates Brazil (state of Roraima to Paraná) and also Venezuela, Colombia, and Guyana. Objective: This work evaluated the antimicrobial activity of hexane, ethyl acetate, and methanol extracts of three species of Marcetia (Marcetia canescens Naud., M. macrophylla Wurdack, and M. taxifolia A.StHil) against several microorganism. In addition, the flavonoids were analyzed in extracts by HPLC-DAD. Materials and methods: The tests were made using Gram-positive (three strains of Staphylococcus aureus) and Gram-negative (two strains of Escherichia coli, a strain of Pseudomonas aeruginosa and another of Salmonella choleraesius) bacteria resistant and nonresistant to antibiotics and yeasts (two strains of Candida albicans and one of C. parapsilosis) by the disk diffusion method. Solid-phase extraction (SPE) was performed on the above extracts to isolate flavonoids, which were subsequently analyzed by high performance liquid chromatography coupled diode array detector (HPLC-DAD). Results: Results showed that extracts inhibited the Gram-positive bacteria and yeast. The hexane extracts possessed the lowest activity, while the ethyl acetate and methanolic extracts were more active. Conclusion: Marcetia taxifolia was more effective (active against 10 microorganisms studied), and only its methanol extract inhibited Gram-negative bacteria (P. aeruginosa and S. choleraesius). SPE and HPLC-DAD analysis showed that M. canescens and M. macrophylla contain glycosylated flavonoids, while the majority of extracts from M. taxifolia were aglycone flavonoids. PMID:23060695

  15. Qualitative and quantitative determination of polyacetylenes in different Bupleurum species by high performance liquid chromatography with diode array detector and mass spectrometry.

    PubMed

    Huang, Hai-Qiang; Su, Juan; Zhang, Xi; Shan, Lei; Zhang, Wei-Dong

    2011-02-25

    Polyacetylenes are main toxic ingredients in Bupleurum longiradiatum, a poisonous plant that has ever been misused as substitutes for Chaihu (Bupleuri Radix). For the first time, a high-performance liquid chromatography method coupled with diode array detector and mass spectrometry (HPLC-DAD-MS) was developed for qualitative and quantitative analysis of nine polyacetylenes in Bupleurum species. All references, including two new polyacetylenes, were isolated from B. longiradiatum and purified using a semi-preparation HPLC chromatography. The analysis was performed on a TSKgel ODS-100V C18 column (3 μm, 150 mm x 4.6 mm i.d.) using a gradient system of acetonitrile and water, with diode array detection (254 nm). The method was validated for linearity, precision, accuracy, limit of detection and quantification. A total of 27 Bupleurum samples were examined with this method, which showed a great variety in the distribution and contents of the polyacetylenes. It was found that polyacetylenes (1-8) were the main ingredients in B. longiradiatum, while a few kinds of polyacetylenes (5-8) were also identified in B. smithii, B. smithii var. parvifolium, B. bicaule and B. angustissimum. However, no polyacetylenes (1-9) were detected in the authentic Chaihu samples and the other Bupleurum species. The results indicated that the toxic B. longiradiatum could readily be distinguished from other medicinal Bupleurum species based on the polyacetylene profiles, and the guidelines and quality control of polyacetylenes for Chaihu are useful. The acute toxicity of the ethanol extract of B. longiradiatum and its fractions was also investigated.

  16. Measurements of the ion fraction and mobility of α - and β -decay products in liquid xenon using the EXO-200 detector

    NASA Astrophysics Data System (ADS)

    Albert, J. B.; Auty, D. J.; Barbeau, P. S.; Beck, D.; Belov, V.; Breidenbach, M.; Brunner, T.; Burenkov, A.; Cao, G. F.; Chambers, C.; Cleveland, B.; Coon, M.; Craycraft, A.; Daniels, T.; Danilov, M.; Daugherty, S. J.; Davis, C. G.; Davis, J.; Delaquis, S.; Der Mesrobian-Kabakian, A.; DeVoe, R.; Didberidze, T.; Dolgolenko, A.; Dolinski, M. J.; Dunford, M.; Fairbank, W.; Farine, J.; Feldmeier, W.; Fierlinger, P.; Fudenberg, D.; Gornea, R.; Graham, K.; Gratta, G.; Hall, C.; Hughes, M.; Jewell, M. J.; Jiang, X. S.; Johnson, A.; Johnson, T. N.; Johnston, S.; Karelin, A.; Kaufman, L. J.; Killick, R.; Koffas, T.; Kravitz, S.; Kuchenkov, A.; Kumar, K. S.; Leonard, D. S.; Licciardi, C.; Lin, Y. H.; Ling, J.; MacLellan, R.; Marino, M. G.; Mong, B.; Moore, D.; Nelson, R.; O'Sullivan, K.; Odian, A.; Ostrovskiy, I.; Piepke, A.; Pocar, A.; Prescott, C. Y.; Robinson, A.; Rowson, P. C.; Russell, J. J.; Schubert, A.; Sinclair, D.; Smith, E.; Stekhanov, V.; Tarka, M.; Tolba, T.; Tsang, R.; Twelker, K.; Vuilleumier, J.-L.; Waite, A.; Walton, J.; Walton, T.; Weber, M.; Wen, L. J.; Wichoski, U.; Wright, J. D.; Wood, J.; Yang, L.; Yen, Y.-R.; Zeldovich, O. Ya.; EXO-200 Collaboration

    2015-10-01

    Alpha decays in the EXO-200 detector are used to measure the fraction of charged Po218 and Bi214 daughters created from α and β decays, respectively. Rn222 α decays in liquid xenon (LXe) are found to produce Po+218 ions 50.3 ±3.0 % of the time, while the remainder of the Po218 atoms are neutral. The fraction of Bi+214 from Pb214 β decays in LXe is found to be 76.4 ±5.7 % , inferred from the relative rates of Po218 and Po214 α decays in the LXe. The average velocity of Po218 ions is observed to decrease for longer drift times. Initially the ions have a mobility of 0.390 ±0.006 cm2/(kVs) , and at long drift times the mobility is 0.219 ±0.004 cm2/(kVs) . Time constants associated with the change in mobility during drift of the Po+218 ions are found to be proportional to the electron lifetime in the LXe.

  17. Noble gas transport during devolatilization of oceanic crust

    NASA Astrophysics Data System (ADS)

    Jackson, C.; Smye, A.; Shuster, D. L.; Parman, S. W.; Kelley, S. P.; Hesse, M. A.; Cooper, R. F.

    2014-12-01

    Here we examine the role of slab dehydration in determining the elemental pattern of recycled noble gases. As a first step, we apply newly reported measurements of He-Ne-Ar (light noble gases) solubility and diffusivity in amphibole to parameterize a 1D diffusive-reaction transport model that simulates noble gas behavior during fluid loss from down-going oceanic crust. Recent experiments demonstrate that noble gases are highly soluble in ring-structured minerals, such as amphibole and other common hydrothermal products in slabs [1]. These results suggest that ring-structured minerals have the potential to strongly influence the budget of noble gases input into subduction zones and the elemental fractionations associated with volatile loss from slabs New measurements of He-Ne-Ar solubility in a suite of amphiboles have been completed utilizing the methodology described in [1]. These new measurements confirm that all light noble gases are highly soluble in amphibole, and that noble gas solubility correlates with the availability of unoccupied ring sites. New experimental measurements of He and Ne diffusivity have also been completed using a step-degassing approach at the Berkeley Geochronology Center. These measurements suggest that vacant ring sites in amphibole act to slow noble gas diffusion. We combine the newly acquired He and Ne diffusivity measurements with literature values for Ar diffusivity [2] to parameterize the diffusive-reaction transport model. Application of these data to the diffusive-reaction transport model yields several new insights. The relative mobility of Ne compared to Ar allows for efficient extraction of Ne from "hot" slabs by shallow depths (<50 km), while Ar is effectively retained to deeper depths, potentially past sub-arc conditions. Noble gas partition coefficients sharply increase with depth, following their increasing non-ideality in supercritical fluids, causing noble gases to partition back into minerals from any fluids retained in

  18. Angstrom-resolved real-time dissection of electrochemically active noble metal interfaces.

    PubMed

    Shrestha, Buddha R; Baimpos, Theodoros; Raman, Sangeetha; Valtiner, Markus

    2014-06-24

    Electrochemical solid|liquid interfaces are critically important for technological applications and materials for energy storage, harvesting, and conversion. Yet, a real-time Angstrom-resolved visualization of dynamic processes at electrified solid|liquid interfaces has not been feasible. Here we report a unique real-time atomistic view into dynamic processes at electrochemically active metal interfaces using white light interferometry in an electrochemical surface forces apparatus. This method allows simultaneous deciphering of both sides of an electrochemical interface-the solution and the metal side-with microsecond resolution under dynamically evolving reactive conditions that are inherent to technological systems in operando. Quantitative in situ analysis of the potentiodynamic electrochemical oxidation/reduction of noble metal surfaces shows that Angstrom thick oxides formed on Au and Pt are high-ik materials; that is, they are metallic or highly defect-rich semiconductors, while Pd forms a low-ik oxide. In contrast, under potentiostatic growth conditions, all noble metal oxides exhibit a low-ik behavior. On the solution side, we reveal hitherto unknown strong electrochemical reaction forces, which are due to temporary charge imbalance in the electric double layer caused by depletion/generation of charged species. The real-time capability of our approach reveals significant time lags between electron transfer, oxide reduction/oxidation, and solution side reaction during a progressing electrode process. Comparing the kinetics of solution and metal side responses provides evidence that noble metal oxide reduction proceeds via a hydrogen adsorption and subsequent dissolution/redeposition mechanism. The presented approach may have important implications for designing emerging materials utilizing electrified interfaces and may apply to bioelectrochemical processes and signal transmission.

  19. Screen-printed electrode-based electrochemical detector coupled with in-situ ionic-liquid-assisted dispersive liquid-liquid microextraction for determination of 2,4,6-trinitrotoluene.

    PubMed

    Fernández, Elena; Vidal, Lorena; Iniesta, Jesús; Metters, Jonathan P; Banks, Craig E; Canals, Antonio

    2014-03-01

    A novel method is reported, whereby screen-printed electrodes (SPELs) are combined with dispersive liquid-liquid microextraction. In-situ ionic liquid (IL) formation was used as an extractant phase in the microextraction technique and proved to be a simple, fast and inexpensive analytical method. This approach uses miniaturized systems both in sample preparation and in the detection stage, helping to develop environmentally friendly analytical methods and portable devices to enable rapid and onsite measurement. The microextraction method is based on a simple metathesis reaction, in which a water-immiscible IL (1-hexyl-3-methylimidazolium bis[(trifluoromethyl)sulfonyl]imide, [Hmim][NTf2]) is formed from a water-miscible IL (1-hexyl-3-methylimidazolium chloride, [Hmim][Cl]) and an ion-exchange reagent (lithium bis[(trifluoromethyl)sulfonyl]imide, LiNTf2) in sample solutions. The explosive 2,4,6-trinitrotoluene (TNT) was used as a model analyte to develop the method. The electrochemical behavior of TNT in [Hmim][NTf2] has been studied in SPELs. The extraction method was first optimized by use of a two-step multivariate optimization strategy, using Plackett-Burman and central composite designs. The method was then evaluated under optimum conditions and a good level of linearity was obtained, with a correlation coefficient of 0.9990. Limits of detection and quantification were 7 μg L(-1) and 9 μg L(-1), respectively. The repeatability of the proposed method was evaluated at two different spiking levels (20 and 50 μg L(-1)), and coefficients of variation of 7 % and 5 % (n = 5) were obtained. Tap water and industrial wastewater were selected as real-world water samples to assess the applicability of the method.

  20. Biomedical Investigations with Laser-Polarized Noble Gas Magnetic Resonance

    NASA Technical Reports Server (NTRS)

    Walsworth, Ronald L.

    2003-01-01

    We pursued advanced technology development of laser-polarized noble gas nuclear magnetic resonance (NMR) as a novel biomedical imaging tool for ground-based and eventually space-based application. This new multidisciplinary technology enables high-resolution gas-space magnetic resonance imaging (MRI)-e.g., of lung ventilation-as well as studies of tissue perfusion. In addition, laser-polarized noble gases (3He and 129Xe) do not require a large magnetic field for sensitive detection, opening the door to practical MRI at very low magnetic fields with an open, lightweight, and low-power device. We pursued two technology development specific aims: (1) development of low-field (less than 0.01 T) noble gas MRI of humans; and (2) development of functional MRI of the lung using laser-polarized noble gas and related techniques.

  1. Thermal conductivity of graphene nanoribbons in noble gaseous environments

    SciTech Connect

    Zhong, Wei-Rong Xu, Zhi-Cheng; Zheng, Dong-Qin; Ai, Bao-Quan

    2014-02-24

    We investigate the thermal conductivity of suspended graphene nanoribbons in noble gaseous environments using molecular dynamics simulations. It is reported that the thermal conductivity of perfect graphene nanoribbons decreases with the gaseous pressure. The decreasing is more obvious for the noble gas with large atomic number. However, the gaseous pressure cannot change the thermal conductivity of defective graphene nanoribbons apparently. The phonon spectra of graphene nanoribbons are also provided to give corresponding supports.

  2. Defense by-products production and utilization program: noble metal recovery screening experiments

    SciTech Connect

    Hazelton, R.F.; Jensen, G.A.; Raney, P.J.

    1986-03-01

    Isotopes of the platinum metals (rutheium, rhodium, and palladium) are produced during uranium fuel fission in nuclear reactors. The strategic values of these noble metals warrant considering their recovery from spent fuel should the spent fuel be processed after reactor discharge. A program to evaluate methods for ruthenium, rhodium, and palladium recovery from spent fuel reprocessing liquids was conducted at Pacific Northwest Laboratory (PNL). The purpose of the work reported in this docuent was to evaluate several recovery processes revealed in the patent and technical literature. Beaker-scale screening tests were initiated for three potential recovery processes: precipitation during sugar denitration of nitric acid reprocessing solutions after plutonium-uranium solvent extraction, adsorption using nobe metal selective chelates on active carbon, and reduction forming solid noble metal deposits on an amine-borane reductive resin. Simulated reprocessing plant solutions representing typical nitric acid liquids from defense (PUREX) or commercial fuel reprocessing facilities were formulated and used for evaluation of the three processes. 9 refs., 3 figs., 9 tabs.

  3. The diverse biological properties of the chemically inert noble gases.

    PubMed

    Winkler, David A; Thornton, Aaron; Farjot, Géraldine; Katz, Ira

    2016-04-01

    The noble gases represent an intriguing scientific paradox. They are extremely inert chemically but display a remarkable spectrum of clinically useful biological properties. Despite a relative paucity of knowledge of their mechanisms of action, some of the noble gases have been used successfully in the clinic. Studies with xenon have suggested that the noble gases as a class may exhibit valuable biological properties such as anaesthesia; amelioration of ischemic damage; tissue protection prior to transplantation; analgesic properties; and a potentially wide range of other clinically useful effects. Xenon has been shown to be safe in humans, and has useful pharmacokinetic properties such as rapid onset, fast wash out etc. The main limitations in wider use are that: many of the fundamental biochemical studies are still lacking; the lighter noble gases are likely to manifest their properties only under hyperbaric conditions, impractical in surgery; and administration of xenon using convectional gaseous anaesthesia equipment is inefficient, making its use very expensive. There is nonetheless a significant body of published literature on the biochemical, pharmacological, and clinical properties of noble gases but no comprehensive reviews exist that summarize their properties and the existing knowledge of their models of action at the molecular (atomic) level. This review provides such an up-to-date summary of the extensive, useful biological properties of noble gases as drugs and prospects for wider application of these atoms.

  4. Noble-gas-rich separates from the Allende meteorite

    NASA Technical Reports Server (NTRS)

    Ott, U.; Mack, R.; Chang, S.

    1981-01-01

    Predominantly carbonaceous HF/HCl-resistant residues from the Allende meteorite are studied. Samples are characterized by SEM/EDXA, X-ray diffraction, INAA, C, S, H, N, and noble gas analyses. Isotopic data for carbon show variations no greater than 5%, while isotopic data from noble gases confirm previously established systematics. Noble gas abundances correlate with those of C and N, and concomitant partial loss of C and normal trapped gas occur during treatments with oxidizing acids. HF/HCl demineralization of bulk meteorite results in similar fractional losses of C and trapped noble gases, which leads to the conclusion that various macromolecular carbonaceous substances serve as the main host phase for normal trapped noble gases and anomalous gases in acid-resistant residues, and as the carrier of the major part of trapped noble gases lost during HF/HCl demineralization. Limits on the possible abundances of dense mineralic host phases in the residues are obtained, and considerations of the nucleogenetic origin for CCF-XE indicate that carbonaceous host phases and various forms of organic matter in carbonaceous meteorites may have a presolar origin.

  5. Noble gas atmospheric monitoring at reprocessing facilities

    SciTech Connect

    Nakhleh, C.W.; Perry, R.T. Jr.; Poths, J.; Stanbro, W.D.; Wilson, W.B.; Fearey, B.L.

    1997-05-01

    The discovery in Iraq after the Gulf War of the existence of a large clandestine nuclear-weapon program has led to an across-the-board international effort, dubbed Programme 93+2, to improve the effectiveness and efficiency of International Atomic Energy Agency (IAEA) safeguards. One particularly significant potential change is the introduction of environmental monitoring (EM) techniques as an adjunct to traditional safeguards methods. Monitoring of stable noble gas (Kr, Xe) isotopic abundances at reprocessing plant stacks appears to be able to yield information on the burnup and type of the fuel being processed. To estimate the size of these signals, model calculations of the production of stable Kr, Xe nuclides in reactor fuel and the subsequent dilution of these nuclides in the plant stack are carried out for two case studies: reprocessing of PWR fuel with a burnup of 35 GWd/tU, and reprocessing of CAND fuel with a burnup of 1 GWd/tU. For each case, a maximum-likelihood analysis is used to determine the fuel burnup and type from the isotopic data.

  6. Nonequilibrium electron dynamics in noble metals

    NASA Astrophysics Data System (ADS)

    del Fatti, N.; Voisin, C.; Achermann, M.; Tzortzakis, S.; Christofilos, D.; Vallée, F.

    2000-06-01

    Electron-electron and electron-lattice interactions in noble metals are discussed in the light of two-color femtosecond pump-probe measurements in silver films. The internal thermalization of a nonequilibrium electron distribution created by intraband absorption of a pump pulse is followed by probing the induced optical property changes in the vicinity of the frequency threshold for the d band to Fermi surface transitions. This is shown to take place with a characteristic time constant of 350 fs, significantly shorter than previously reported in gold. This difference is ascribed to a weaker screening of the electron-electron interaction by the d-band electrons in silver than in gold. These results are in quantitative agreement with numerical simulations of the electron relaxation dynamics using a reduced static screening of the electron-electron Coulomb interaction, and including bound electron screening. Electron-lattice thermalization has been studied using a probe frequency out of resonance with the interband transitions. In both materials, the transient nonthermal nature of the electron distribution leads to the observation of a short-time delay reduction of the energy-loss rate of the electron gas to the lattice, in very good agreement with our theoretical model.

  7. Dating native gold by noble gas analyses

    NASA Technical Reports Server (NTRS)

    Niedermann, S.; Eugster, O.; Hofmann, B.; Thalmann, CH.; Reimold, W. U.

    1993-01-01

    Our recent work on He, Ne, and Ar in Alpine gold samples has demonstrated that gold is extremely retentive for He and could thus, in principle, be used for U/Th-He-4 dating. For vein-type gold from Brusson, Northern Italy, we derived a U/Th-He-4 age of 36 Ma, in agreement with the K-Ar formation age of associated muscovites and biotites. However, in placer gold from the Napf area, Central Switzerland, we observed large excesses of both He-4 and radiogenic Ar-40 (Ar-40 sub rad, defined as Ar-40-295.5-Ar-.36). The gas release systematics indicate two distinct noble gas components, one of which is released below about 800 C and the other one at the melting point of gold (1064 C). We now present results of He and Xe measurements in a 1 g placer gold sample from the river Kruempelgraben, as well as He and Ar data for Brusson vein-type gold and for gold from the Lily Gold Mine, South Africa. We calculate reasonable U/Th-He-4 as well as U-Xe ages based on those gases which are released at approximately 800 C. Probably the low-temperature components represent in-situ-produced radiogenic He and fission Xe, whereas the gases evolving when gold melts have been trapped during gold formation. Therefore, only the low-temperature components are relevant for dating purposes.

  8. Underground Sources of Radioactive Noble Gas

    SciTech Connect

    Hayes, James C.; Bowyer, Ted W.; Cordova, Elsa A.; Kirkham, Randy R.; Misner, Alex C.; Olsen, Khris B.; Woods, Vincent T.; Emer, Dudley

    2013-05-01

    It is well known that radon is present in relatively high concentrations below the surface of the Earth due to natural decay of uranium and thorium. However, less information is available on the background levels of other isotopes such as 133Xe and 131mXe produced via spontaneous fission of either manmade or naturally occurring elements. The background concentrations of radioxenon in the subsurface are important to understand because these isotopes potentially can be used to confirm violations of the Comprehensive Nuclear-Test-Ban Treaty (CTBT) during an On-Site Inspection (OSI). Recently, Pacific Northwest National Laboratory (PNNL) measured radioxenon concentrations from the subsurface at the Nevada Nuclear Security Site (NNSS—formerly known as the Nevada Test Site) to determine whether xenon isotope background levels could be detected from spontaneous fission of naturally occurring uranium or legacy 240Pu as a result of historic nuclear testing. In this paper, we discuss the results of those measurements and review the sources of xenon background that must be taken into account during OSI noble gas measurements.

  9. RADIATION DETECTOR

    DOEpatents

    Wilson, H.N.; Glass, F.M.

    1960-05-10

    A radiation detector of the type is described wherein a condenser is directly connected to the electrodes for the purpose of performing the dual function of a guard ring and to provide capacitance coupling for resetting the detector system.

  10. Noble magnetic barriers in the ASDEX UG tokamak

    NASA Astrophysics Data System (ADS)

    Ali, Halima; Punjabi, Alkesh; Vazquez, Justin

    2010-02-01

    The second-order perturbation method of creating invariant tori inside chaos in Hamiltonian systems (Ali, H.; Punjabi, A. Plasma Phys. Contr. F. 2007, 49, 1565-1582) is applied to the axially symmetric divertor experiment upgrade (ASDEX UG) tokamak to build noble irrational magnetic barriers inside chaos created by resonant magnetic perturbations (m, n)=(3, 2)+(4, 3), with m and n the poloidal and toroidal mode numbers of the Fourier expansion of the magnetic perturbation. The radial dependence of the Fourier modes is ignored. The modes are considered to be locked and have the same amplitude δ. A symplectic mathematical mapping in magnetic coordinates is used to integrate magnetic field line trajectories in the ASDEX UG. Tori with noble irrational rotational transform are the last ones to be destroyed by perturbation in Hamiltonian systems. For this reason, noble irrational magnetic barriers are built inside chaos, and the strongest noble irrational barrier is identified. Three candidate locations for the strongest noble barrier in ASDEX UG are selected. All three candidate locations are chosen to be roughly midway between the resonant rational surfaces ψ32 and ψ43. ψ is the magnetic coordinate of the flux surface. The three candidate surfaces are the noble irrational surfaces close to the surface with q value that is a mediant of q=3/2 and 4/3, q value of the physical midpoint of the two resonant surfaces, and the q value of the surface where the islands of the two perturbing modes just overlap. These q values of the candidate surfaces are denoted by q MED, q MID, and q OVERLAP. The strongest noble barrier close to q MED has the continued fraction representation (CFR) [1;2,2,1∞] and exists for δ≤2.6599×10-4; the strongest noble barrier close to q MID has CFR [1;2,2,2,1∞] and exists for δ≤4.6311×10-4; and the strongest noble barrier close to q OVERLAP has CFR [1;2,2,6,2,1∞] and exists for δ≤1.367770×10-4. From these results, the strongest

  11. Contrasting behavior of noble-metal elements during magmatic differentiation in basalts from the Cook Islands, Polynesia

    NASA Astrophysics Data System (ADS)

    Tatsumi, Yoshiyuki; Oguri, Kiwamu; Shimoda, Gen; Kogiso, Tetsu; Barsczus, Hans G.

    2000-02-01

    Concentrations of noble metals (Ir, Ru, Rh, Pt, Pd, and Au) in ocean-island basalts from the Cook Islands, Polynesia, were determined by improved fire-assay and tellurium coprecipitation techniques with an inductively-coupled-plasma mass spectrometer. Isotope, major element, and trace element compositions of these basalts indicate that the present samples include distinctive HIMU (high μ = high 238U/204Pb) and normal non-HIMU basalts. Examination based on Ni-Mg-Fe partitioning between olivine and liquid suggests an only minor effect of accumulation of phenocrysts in governing the compositional variations of the present samples. The fractionation trends obtained show monotonic decrease and increase in noble-metal elements with decreasing MgO content in HIMU and non-HIMU basalts, respectively. These characteristic trends indicate that HIMU magmas are differentiated by fractional crystallization and have higher sulfide/silicate ratios than non-HIMU basalts.

  12. Cross-Calibration of Secondary Electron Multiplier in Noble Gas Analysis

    NASA Astrophysics Data System (ADS)

    Santato, Alessandro; Hamilton, Doug; Deerberg, Michael; Wijbrans, Jan; Kuiper, Klaudia; Bouman, Claudia

    2015-04-01

    The latest generation of multi-collector noble gas mass spectrometers has decisively improved the precision in isotopic ratio analysis [1, 2] and helped the scientific community to address new questions [3]. Measuring numerous isotopes simultaneously has two significant advantages: firstly, any fluctuations in signal intensity have no effect on the isotope ratio and secondly, the analysis time is reduced. This particular point becomes very important in static vacuum mass spectrometry where during the analysis, the signal intensity decays and at the same time the background increases. However, when multi-collector analysis is utilized, it is necessary to pay special attention to the cross calibration of the detectors. This is a key point in order to have accurate and reproducible isotopic ratios. In isotope ratio mass spectrometry, with regard to the type of detector (i.e. Faraday or Secondary Electron Multiplier, SEM), analytical technique (TIMS, MC-ICP-MS or IRMS) and isotope system of interest, several techniques are currently applied to cross-calibrate the detectors. Specifically, the gain of the Faraday cups is generally stable and only the associated amplifier must be calibrated. For example, on the Thermo Scientific instrument control systems, the 1011 and 1012 ohm amplifiers can easily be calibrated through a fully software controlled procedure by inputting a constant electric signal to each amplifier sequentially [4]. On the other hand, the yield of the SEMs can drift up to 0.2% / hour and other techniques such as peak hopping, standard-sample bracketing and multi-dynamic measurement must be used. Peak hopping allows the detectors to be calibrated by measuring an ion beam of constant intensity across the detectors whereas standard-sample bracketing corrects the drift of the detectors through the analysis of a reference standard of a known isotopic ratio. If at least one isotopic pair of the sample is known, multi-dynamic measurement can be used; in this

  13. Development of Paper, Chemical Agent Detector, 3-Way Liquid Containing Non-Mutagenic Dyes. 2. Replacement of the Blue Indicator Dye Ethyl-bis-(2,4- Dinitrophenyl Acetate (EDA)

    DTIC Science & Technology

    1988-06-01

    OL JU)OY (ý2ýPj 00 (V)~ Oetence nationale DTI DEVELOPIIEnT OF PAPER, CHEMICAL AGENT DETECTOR, 3-WAY LIQUID CONTAINING NON-MUTAGENIC DYES . Hi...REPLACEMENT OF THE BLUE INflICATOR DYE ETH.YL-b is-(2.4-DI NITROPH ENYL) ACETATE IEDA) by D. Thoravala, J.W. Bovenkampb, R.W. Betsa and B.V. Lcroixb...NON-MUTAGENIC DYES . n-REPLACEMENT OF THE BLUE INDICATOR DYE ETHYL-bis-(2,4-DINITROPHENYL) ACETATE (EDA) by D. Thoraval and R.W. Bets Anachemic Canada

  14. Fast Conversion of Ionic Liquids and Poly(Ionic Liquid)s into Porous Nitrogen-Doped Carbons in Air.

    PubMed

    Men, Yongjun; Ambrogi, Martina; Han, Baohang; Yuan, Jiayin

    2016-04-08

    Ionic liquids and poly(ionic liquid)s have been successfully converted into nitrogen-doped porous carbons with tunable surface area up to 1200 m²/g at high temperatures in air. Compared to conventional carbonization process conducted under inert gas to produce nitrogen-doped carbons, the new production method was completed in a rather shorter time without noble gas protection.

  15. Fast Conversion of Ionic Liquids and Poly(Ionic Liquid)s into Porous Nitrogen-Doped Carbons in Air

    PubMed Central

    Men, Yongjun; Ambrogi, Martina; Han, Baohang; Yuan, Jiayin

    2016-01-01

    Ionic liquids and poly(ionic liquid)s have been successfully converted into nitrogen-doped porous carbons with tunable surface area up to 1200 m2/g at high temperatures in air. Compared to conventional carbonization process conducted under inert gas to produce nitrogen-doped carbons, the new production method was completed in a rather shorter time without noble gas protection. PMID:27070588

  16. Measuring radioactive noble gases by absorption in polycarbonates and other organics: From radon indoors to nuclear safety

    NASA Astrophysics Data System (ADS)

    Pressyanov, Dobromir S.

    2013-07-01

    The report summarizes recent research and practice of using materials with high absorption ability to noble gases to measure their radioactive isotopes. Most of the studies employ bisphenol-A based polycarbonates, because of their remarkably high absorption ability to noble gases. This is the material of which commercial CDs/DVDs are made and they may serve as serendipitous, already available in dwellings, radon and thoron detectors. We present the essence of the gathered experimental evidence that the CD/DVD method can successfully address some long-lasted problems in radon dosimetry: The first is making sufficiently precise retrospective 222Rn dosimetry for the purposes of epidemiological studies and risk estimation. The second is rapid identification of buildings with radon problem. We demonstrate how this can be used to develop an integrated approach to the radon problem. Within this approach detection, diagnostic and mitigation are considered as an unified whole, and the interval between the decision to provide disks for analysis and the complete mitigation of the building, if radon problem is identified, is short. Besides radon and thoron, bisphenol-A based polycarbonates were successfully used to measure 85Kr and 133Xe for the purposes of the effluents control and nuclear safety of nuclear installations. The perspectives to employ other organic materials in which noble gases are highly soluble for measurement of their radioactive isotopes are also discussed.

  17. Demonstration of neutron detection utilizing open cell foam and noble gas scintillation

    SciTech Connect

    Lavelle, C. M. Miller, E. C.; Coplan, M.; Thompson, Alan K.; Vest, Robert E.; Yue, A. T.; Kowler, A. L.; Koeth, T.; Al-Sheikhly, M.; Clark, Charles W.

    2015-03-02

    We present results demonstrating neutron detection via a closely spaced converter structure coupled to low pressure noble gas scintillation instrumented by a single photo-multiplier tube (PMT). The converter is dispersed throughout the gas volume using a reticulated vitreous carbon foam coated with boron carbide (B{sub 4}C). A calibrated cold neutron beam is used to measure the neutron detection properties, using a thin film of enriched {sup 10}B as a reference standard. Monte Carlo computations of the ion energy deposition are discussed, including treatment of the foam random network. Results from this study indicate that the foam shadows a significant portion of the scintillation light from the PMT. The high scintillation yield of Xe appears to overcome the light loss, facilitating neutron detection and presenting interesting opportunities for neutron detector design.

  18. Fluctuation capture in dense gases and liquids - trapping, detrapping and non-equilibrium transport

    NASA Astrophysics Data System (ADS)

    Cocks, Daniel; White, Ron

    2016-09-01

    When charged particles travel through a background of a dense gas or liquid the correlations in the fluid significantly modify the transport of the charged particle. In particular, a new process becomes available, in which the particle is captured into a local fluctuation (bubble or cluster) of the fluid. The trapping has an influence on all transport coefficients, especially annihilation rates of positrons and positronium. Understanding fluctuation capture is important in medical diagnostics, therapy and particle detectors in the low-energy regime, but has so far been unable to be accounted for in transport simulations. We present a new framework that produces energy-resolved ``capture cross sections'' σcap(ɛ) along with ``waiting time distributions'' Θ(t) which allow transport theories to include capture as a process. We demonstrate good agreement between our ab initio calculations and experimental measurements of electrons and positrons in dense noble-gas fluids.

  19. Atomic forces between noble gas atoms, alkali ions, and halogen ions for surface interactions

    NASA Technical Reports Server (NTRS)

    Wilson, J. W.; Outlaw, R. A.; Heinbockel, J. H.

    1988-01-01

    The components of the physical forces between noble gas atoms, alkali ions, and halogen ions are analyzed and a data base developed from analysis of the two-body potential data, the alkali-halide molecular data, and the noble gas crystal and salt crystal data. A satisfactory global fit to this molecular and crystal data is then reproduced by the model to within several percent. Surface potentials are evaluated for noble gas atoms on noble gas surfaces and salt crystal surfaces with surface tension neglected. Within this context, the noble gas surface potentials on noble gas and salt crystals are considered to be accurate to within several percent.

  20. Defining Noble Gas Partitioning for Carbon Capture and Storage Environments

    NASA Astrophysics Data System (ADS)

    Warr, O.; Masters, A.; Rochelle, C.; Ballentine, C. J.

    2014-12-01

    For viable CCS implementation variables such as CO2 dissolution rates, reactions with the host rock and the extent of groundwater interaction must be accurately constrained. Noble gases play an important role in these systems [e.g. 1,2]. Their application, however, requires accurate Henry's constants within dense CO2-H2O systems. Current interpretations use pure noble gas-H2O partitioning data [3,4] and assume CO2-noble gas interactions are negligible, even at high (>700 kg/m3) CO2 densities [2]. To test this assumption we experimentally determined noble gas CO2-H2O partitioning for the 170-656 kg/m3 CO2 density range; representative of most CCS environments. Contrary to assumption, CO2 density significantly affected noble gas partition coefficients. For helium, increasing CO2 density resulted in a negative deviation trend from CO2-free values whilst for argon, krypton and xenon strong, positive deviations were observed. At 656 kg/m3 these deviations were -35%, 74%, 114% and 321% respectively. This is interpreted as the CO2 phase acting as a polar solvent inducing polarisation in the noble gases. Deviation trends are well defined using a 2nd order polynomial. The effect of a dense CO2 phase can now be incorporated into existing noble gas models. We also present results from a Gibbs-Ensemble Monte Carlo molecular simulation to model partitioning for this binary system. This fundamental technique makes predictions based on the pair-potentials of interaction between the molecules. Here it gives the phase compositions and Henry coefficients for noble gases. With a proven ability in accurately replicating both the CO2-H2O system and low pressure noble gas Henry constants the focus is now on fully optimising the model to match high pressure observations. [1] Gilfillan et al. (2009) Nature 458 614-618 [2] Gilfillan et al. (2008) GCA 72 1174-1198 [3] Crovetto et al. (1982) J.Chem.Phys. 76 1077-1086 [4] Ballentine et al. in Porcelli et al. (eds.) (2002) Rev.Min.Geo. 47 539-614.

  1. Solar Noble Gases in Polymict Ureilites and an Update on Ureilite Noble Gas Data

    NASA Astrophysics Data System (ADS)

    Ott, U.; Lohr, H. P.; Begemann, F.

    1993-07-01

    Ureilites are one of the least understood classes of meteorites; they show signs of being processed, but also appear to be primitive, with abundant carbon and trapped noble gases [1-6]. We have now begun to analyze a number of recently recovered specimens: one from the Saharan desert (Acfer 277) amd five from the Antarctic (LEW 85328, LEW 85440, EET 87720, FRO 90036, and FRO 90054). Analyses of Acfer 277, LEW 85328, and EET 87720 are complete (Table 1). Solar noble gases are present in polymict EET 87720, as shown by the three- isotope plot of Fig. 1. There, in contrast to the bulk data point for Acfer 277, data points for EET 87720 deviate from a mixing line between "typical" spallation Ne (as approximated here by the spallation-dominated 1800 degrees C step for EET 87720) and Ne-U [7] toward higher ^20Ne/^22Ne. A line fitted to the EET 87720 data points passes slightly below Ne-B [8]. The situation is similar for sample F1 from polymict EET 83309 [9], which is shown for comparison. Additional support for the presence of solar gases arises from the abundance of ^4He (~9 x 10^-5 cm^3 STP/g in EET 87720-F1, corrected for spallogenic contributions), which in both cases is far higher than in other ureilite bulk samples [6,10]. Also, in the ratio of spallation-corrected ^4He to trapped ^36Ar, these two polymict ureilites clearly stand out. Helium-4/argon-36 ratios in EET 87720-F1 and EET 83309-F1 are ~20 and ~28 respectively, at least 1 order of magnitude higher than in bulk monomict ureilites and 2 orders of magnitude higher than what appears typical of ureilite diamonds [6]. Nilpena, another polymict ureilite [11], also has a ^4He/^36Ar ratio (2.1 in Nilpena II-1 [7]) higher than all monomict ureilites but one (Dingo Pup Donga), indicating the presence of solar noble gases (in variable contents) as a possible general feature of polymict ureilites, similar to the presence in them of nitrogen with high delta(^15N/^14N) [12]. Monomict LEW 85328 has a very high (^22Ne

  2. Biomedical Investigations with Laser-Polarized Noble Gas Magnetic Resonance

    NASA Technical Reports Server (NTRS)

    Walsworth, Ronald L.

    2001-01-01

    We are developing laser-polarized noble gas nuclear magnetic resonance (NMR) as a novel biomedical imaging tool for ground-based and eventually space-based application. This emerging multidisciplinary technology enables high-resolution gas-space magnetic resonance imaging (MRI) (e.g., of lung ventilation) as well as studies of tissue perfusion. In addition, laser-polarized noble gases (He-3 and Xe-129) do not require a large magnetic field for sensitive detection, opening the door to practical MRI at very low magnetic fields with an open, lightweight, and low-power device. We are pursuing two specific aims in this research. The first aim is to develop a low-field (< 0.01 T) instrument for noble gas MRI of humans, and the second aim is to develop functional MRI of the lung using laser-polarized Xe-129 and related techniques.

  3. Noble-gas-rich separates from ordinary chondrites

    NASA Astrophysics Data System (ADS)

    Moniot, R. K.

    1980-02-01

    Acid-resistant residues were prepared by HCl-HF demineralization of three H-type ordinary chondrites: Brownfield 1937 (H3), Dimmitt (H3, 4), and Estacado (H6). These residues were found to contain a large proportion of the planetary-type trapped Ar, Kr, and Xe in the meteorites. The similarity of these acid residues to those from carbonaceous chondrites and LL-type ordinary chondrites suggests that the same phase carries the trapped noble gases in all these diverse meteorite types. Because the H group represents a large fraction of all meteorites, this result indicates that the gas-rich carrier phase is as universal as the trapped noble-gas component itself. When treated with an oxidizing etchant, the acid residues lost almost all their complement of noble gases.

  4. Method and apparatus for measuring purity of noble gases

    SciTech Connect

    Austin, Robert

    2008-04-01

    A device for detecting impurities in a noble gas includes a detection chamber and a source of pulsed ultraviolet light. The pulse of the ultraviolet light is transferred into the detection chamber and onto a photocathode, thereby emitting a cloud of free electrons into the noble gas within the detection chamber. The cloud of electrons is attracted to the opposite end of the detection chamber by a high positive voltage potential at that end and focused onto a sensing anode. If there are impurities in the noble gas, some or all of the electrons within the cloud will bond with the impurity molecules and not reach the sensing anode. Therefore, measuring a lower signal at the sensing anode indicates a higher level of impurities while sensing a higher signal indicates fewer impurities. Impurities in the range of one part per billion can be measured by this device.

  5. Using noble gas ratios to determine the origin of ground ice

    NASA Astrophysics Data System (ADS)

    Utting, Nicholas; Lauriol, Bernard; Lacelle, Denis; Clark, Ian

    2016-01-01

    Argon, krypton and xenon have different solubilities in water, meaning their ratios in water are different from those in atmospheric air. This characteristic is used in a novel method to distinguish between ice bodies which originate from the compaction of snow (i.e. buried snow banks, glacial ice) vs. ice which forms from the freezing of groundwater (i.e. pingo ice). Ice which forms from the compaction of snow has gas ratios similar to atmospheric air, while ice which forms from the freezing of liquid water is expected to have gas ratios similar to air-equilibrated water. This analysis has been conducted using a spike dilution noble gas line with gas extraction conducted on-line. Samples were mixed with an aliquot of rare noble gases while being melted, then extracted gases are purified and cryogenically separated. Samples have been analysed from glacial ice, buried snow bank ice, intrusive ice, wedge ice, cave ice and two unknown ice bodies. Ice bodies which have formed from different processes have different gas ratios relative to their formation processes.

  6. Biomimetic synthesis of noble metal nanocrystals

    NASA Astrophysics Data System (ADS)

    Chiu, Chin-Yi

    At the nanometer scale, the physical and chemical properties of materials heavily depend on their sizes and shapes. This fact has triggered considerable efforts in developing controllable nanomaterial synthesis. The controlled growth of colloidal nanocrystal is a kinetic process, in which high-energy facets grow faster and then vanish, leading to a nanocrystal enclosed by low-energy facets. Identifying a surfactant that can selectively bind to a particular crystal facet and thus lower its surface energy, is critical and challenging in shape controlled synthesis of nanocrystals. Biomolecules exhibiting exquisite molecular recognition properties can be exploited to precisely engineer nanostructured materials. In the first part of my thesis, we employed the phage display technique to select a specific multifunctional peptide sequence which can bind on Pd surface and mediate Pd crystal nucleation and growth, achieving size controlled synthesis of Pd nanocrystals in aqueous solution. We further demonstrated a rational biomimetic approach to the predictable synthesis of nanocrystals enclosed by a particular facet in the case of Pt. Specifically, Pt {100} and Pt {111} facet-specific peptides were identified and used to synthesize Pt nanocubes and Pt nano-tetrahedrons, respectively. The mechanistic studies of Pt {111} facet-specific peptide had led us to study the facet-selective adsorption of aromatic molecules on noble metal surfaces. The discoveries had achieved the development of design strategies to select facet-selective molecules which can synthesize nanocrystals with expected shapes in both Pt and Pd system. At last, we exploited Pt facet-specific peptides and controlled the molecular interaction to produce one- and three- dimensional nanostructures composed of anisotropic nanoparticles in synthetic conditions without supramolecular pre-organization, demonstrating the full potential of biomolecules in mediating material formation process. My research on biomimetic

  7. Spectroscopic enhancement from noble mettalic nanoparticles

    NASA Astrophysics Data System (ADS)

    Tsai, Shu-Ju

    2011-12-01

    Resonant coupling of localized surface plasmon resonances (LSPRs) in noble metallic nanostructures to incident radiation and the related subject of localized behavior of electromagnetic waves are currently of great interest due to their potential application to sensors, biochemical assays, optical transmission, and photovoltaic devices. My thesis research is made up of two related parts. In part one I examined enhanced fluorescence in dye molecules in proximity to Ag nanostructures. In part two I studied the effect of Au nanostructure arrays on the performance of poly(3-hexylthiophene-2,5-diyl) : [6,6]-phenyl-C61-butyric acid methyl ester (P3HT:PCBM) bulk heterojunction (BHJ) organic solar cells (OSCs). Nanostructures were fabricated by two different methods: e-beam lithography (top down) and spray pyrolysis (bottom up). Using e-beam lithography, we produced arrays of nanostructures with well defined shapes, sizes, and spacings. By systematically varying these topographical parameters, we measured their effect on nanometer-sized metallic structure-enhanced fluorescence (nMEF) and on absorption and external quantum efficiency (EQE) in OSC devices as a function of optical wavelength. In analyzing experimental results, we carried out numerical simulations of the local electric field under incident light, across plasmonic resonances. The comparison between the calculated local field squared and measured fluorescence/EQE provides physical insight on the configuration-dependence of these two processes. Our results indicate that local field enhancement near nanostructures is dominant in nMEF, and that the local field is strongly affected by the substrate and device architectures. For the OSCs, both measurements and calculations show that absorbance within the active layer is enhanced only in a narrow band of wavelengths (˜640-720 nm) where the active layer is not very absorbing for our prototype nanopillar-patterned devices. The peak enhancement for 180 nm wide Au

  8. Fractionation of the noble metals by physical processes

    NASA Astrophysics Data System (ADS)

    Ballhaus, Chris; Bockrath, Conny; Wohlgemuth-Ueberwasser, Cora; Laurenz, Vera; Berndt, Jasper

    2006-12-01

    During partial melting in the earth’s mantle, the noble metals become fractionated. Os, Ir, Ru, and Rh tend to remain in the mantle residue whereas Pt, Pd, and Re behave mildly incompatible and are sequestered to the silicate melt. There is consensus that sulfide plays a role in the fractionation process; the major noble metal repository in the mantle is sulfide, and most primitive mantle melts are sulfide-saturated when they leave their mantle sources. However, with sulfide-silicate partitioning, the fractionation cannot be modeled properly. All sulfide-silicate partition coefficients are so extremely high that a silicate melt segregating from a mantle source with residual sulfide should be largely platinum-group elements free. We offer a physical alternative to sulfide-silicate chemical partitioning and provide a mechanism of generating a noble metal-rich melt from a sulfide-saturated source: Because sulfide is at least partially molten at asthenospheric temperature, it will behave physically incompatible during melt segregation, and a silicate melt segregating from a mantle residue will entrain molten residual sulfide in suspension and incorporate it in the basaltic pool melt. The noble metal abundances of a basalt then become independent of sulfide-silicate chemical partitioning. They reflect the noble metal abundances in the drained sulfide fraction as well as the total amount of sulfide entrained. Contrary to convention, we suggest that a fertile, sulfide-rich mantle source has more potential to generate a noble metal-enriched basaltic melt than a refractory mantle source depleted by previous partial melting events.

  9. Howardite Noble Gases as Indicators of Asteroid Surface Processing

    NASA Technical Reports Server (NTRS)

    Cartwright, J. A.; Mittlefehldt, D. W.; Herrin, J. S.; Ott, U.

    2011-01-01

    The HED (Howardite, Eucrite and Diogenite) group meteorites likely or iginate from the Asteroid 4 Vesta - one of two asteroid targets of NA SA's Dawn mission. Whilst Howardites are polymict breccias of eucriti c and diogenitic material that often contain "regolithic" petrologica l features, neither their exact regolithic nature nor their formation processes are well defined. As the Solar Wind (SW) noble gas compon ent is implanted onto surfaces of solar system bodies, noble gas anal yses of Howardites provides a key indicator of regolithic origin. In addition to SW, previous work by suggested that restricted Ni (300-12 00 micro g/g) and Al2O3 (8-9 wt%) contents may indicate an ancient we ll-mixed regolith. Our research combines petrological, compositional and noble gas analyses to help improve understanding of asteroid reg olith formation processes, which will play an intergral part in the i nterpretation of Dawn mission data. Following compositional and petrological analyses, we developed a regolith grading scheme for our sampl e set of 30 Howardites and polymict Eucrites. In order to test the r egolith indicators suggested by, our 8 selected samples exhibited a r ange of Ni, Al2O3 contents and regolithic grades. Noble gas analyses were performed using furnace stepheating on our MAP 215-50 noble gas mass spectrometer. Of our 8 howardites, only 3 showed evidence of SW noble gases (e.g approaching Ne-20/Ne-22 approximately equals 13.75, Ne-21/Ne-22 approximately equals 0.033). As these samples display low regolithic grades and a range of Ni and Al2O3 contents, so far we are unable to find any correlation between these indicators and "regolit hic" origin. These results have a number of implications for both Ho wardite and Vesta formation, and may suggest complex surface stratigr aphies and surface-gardening processes.

  10. Smoke Detector

    NASA Technical Reports Server (NTRS)

    1979-01-01

    In the photo, Fire Chief Jay Stout of Safety Harbor, Florida, is explaining to young Richard Davis the workings of the Honeywell smoke and fire detector which probably saved Richard's life and that of his teen-age brother. Alerted by the detector's warning, the pair were able to escape their burning home. The detector in the Davis home was one of 1,500 installed in Safety Harbor residences in a cooperative program conducted by the city and Honeywell Inc.

  11. NMR and structural features of noble-metal fluorides

    SciTech Connect

    Gabuda, S.P.; Zemskov, S.V.

    1987-11-01

    NMR studies are reported on the structures of binary and other noble-metal fluorides. Revised measurements have been made on /sup 19/F chemical shifts and the anisotropy in them. A relationship is considered between the screening tensor for /sup 19/F and the electronic structure of the molecule or ion containing the noble-metal cation in the electronic configuration d/sup 6/, d/sup 8/, or d/sup 10/. The observed anomalous shifts in this class of compound are explained qualitatively in terms of paired electrons in filled d shells affecting the result within the framework of the classical theory of magnetic nuclear screening.

  12. Isotopic mass-dependence of noble gas diffusion coefficients inwater

    SciTech Connect

    Bourg, I.C.; Sposito, G.

    2007-06-25

    Noble gas isotopes are used extensively as tracers inhydrologic and paleoclimatic studies. These applications requireknowledge of the isotopic mass (m) dependence of noble gas diffusioncoefficients in water (D), which has not been measured but is estimatedusing experimental D-values for the major isotopes along with an untestedrelationship from kinetic theory, D prop m-0.5. We applied moleculardynamics methods to determine the mass dependence of D for four noblegases at 298 K, finding that D prop m-beta with beta<0.2, whichrefutes the kinetic theory model underlying all currentapplications.

  13. Fullerenes: A New Carrier Phase for Noble Gases in Meteorites

    NASA Technical Reports Server (NTRS)

    Becker, Luann

    2004-01-01

    The major focus of our research effort has been to measure the noble gases encapsulated within fullerenes, a new carbon carrier phase and compare it to the myriad of components found in the bulk meteorite acid residues. We have concentrated on the carbonaceous chondrites (Allende, Murchison and Tagish Lake) since they have abundant noble gases, typically with a planetary signature that dominates the stepped-release of the meteorite bulk acid residue. They also contain an extractable fullerene component that can be isolated and purified from the same bulk material.

  14. Laser beam methane detector

    NASA Technical Reports Server (NTRS)

    Hinkley, E. D., Jr.

    1981-01-01

    Instrument uses infrared absorption to determine methane concentration in liquid natural gas vapor. Two sensors measure intensity of 3.39 mm laser beam after it passes through gas; absorption is proportional to concentration of methane. Instrument is used in modeling spread of LNG clouds and as leak detector on LNG carriers and installations. Unit includes wheels for mobility and is both vertically and horizontally operable.

  15. Commissioning the SNO+ detector

    NASA Astrophysics Data System (ADS)

    Descamps, Freija; SNO+ Collaboration

    2016-09-01

    The SNO+ experiment is the successor to the Sudbury Neutrino Observatory (SNO), in which SNO's heavy water is replaced by approximately 780T of liquid scintillator (LAB). The combination of the 2km underground location, the use of ultra-clean materials and the high light-yield of the liquid scintillator means that a low background level and a low energy threshold can be achieved. This creates a new multipurpose neutrino detector with the potential to address a diverse set of physics goals, including the detection of reactor, solar, geo- and supernova neutrinos. A main physics goal of SNO+ is the search for neutrinoless double beta decay. By loading the liquid scintillator with 0.5% of natural Tellurium, resulting in about 1300kg of 130Te (isotopic abundance is slightly over 34%), a competitive sensitivity to the effective neutrino mass can be reached. This talk will present the status of the SNO+ detector, specifically the results and status of the detector commissioning with water.

  16. Noble Metal Nanoparticle-loaded Mesoporous Oxide Microspheres for Catalysis

    NASA Astrophysics Data System (ADS)

    Jin, Zhao

    Noble metal nanoparticles/nanocrystals have attracted much attention as catalysts due to their unique characteristics, including high surface areas and well-controlled facets, which are not often possessed by their bulk counterparts. To avoid the loss of their catalytic activities brought about by their size and shape changes during catalytic reactions, noble metal nanoparticles/nanocrystals are usually dispersed and supported finely on solid oxide supports to prevent agglomeration, nanoparticle growth, and therefore the decrease in the total surface area. Moreover, metal oxide supports can also play important roles in catalytic reactions through the synergistic interactions with loaded metal nanoparticles/nanocrystals. In this thesis, I use ultrasonic aerosol spray to produce hybrid microspheres that are composed of noble metal nanoparticles/nanocrystals embedded in mesoporous metal oxide matrices. The mesoporous metal oxide structure allows for the fast diffusion of reactants and products as well as confining and supporting noble metal nanoparticles. I will first describe my studies on noble metal-loaded mesoporous oxide microspheres as catalysts. Three types of noble metals (Au, Pt, Pd) and three types of metal oxide substrates (TiO2, ZrO2, Al 2O3) were selected, because they are widely used for practical catalytic applications involved in environmental cleaning, pollution control, petrochemical, and pharmaceutical syntheses. By considering every possible combination of the noble metals and oxide substrates, nine types of catalyst samples were produced. I characterized the structures of these catalysts, including their sizes, morphologies, crystallinity, and porosities, and their catalytic performances by using a representative reduction reaction from nitrobenzene to aminobenzene. Comparison of the catalytic results reveals the effects of the different noble metals, their incorporation amounts, and oxide substrates on the catalytic abilities. For this particular

  17. Improvement in Ge Detector Cooling

    DTIC Science & Technology

    2008-09-01

    lifetime and integrity, improve performance, and resolve the need to procure and handle liquid nitrogen (LN2). Both cryocoolers offer advantages over...place, the 22-liter reservoir of LN2 provides up to 7 days of cooling to the detector with no risk of a partial thermal cycle or warm -up. The detector... warmed for repairs. Moreover, the interchangeability of dipsticks and Cryo-Cycle™ coolers allows independent replacement of either of the two most

  18. Field Enhancement using Noble Metal Structures

    NASA Astrophysics Data System (ADS)

    Liu, Benliang

    Resonance may be one of the most fundamental rules of nature. Electromagnetic resonance at nanometer scale could produce a giant field enhancement at optical frequency, providing a way to measure and control the process of atoms and molecules at single molecule scale. For example, the giant field enhancement would provide single molecule sensitivity for Raman scattering, which provides unique tools in measuring the quantity in extremely low concentration. In addition, light-emitting diodes could have high brightness but low input power that would be revolutionary in the optoelectronic industry. Although light enhancement is promising in several key technology areas, there are several challenges remain to be tackled. In particular, since the field enhancement is so strongly geometry dependent that slight modification of the geometry can lead to large variations in the outcome, a thorough understanding in how the geometry of the structure affects the field enhancement and creating proper methods to fabricate these structures reproducibly is of most importance. This thesis is devoted to design, fabrication and characterization of field enhancement generated on the surface of noble metals such as silver or gold with 1D structure. The s-polarized field enhancement arising from one-dimensional metal gratings is designed and optimized by using Rigorous Coupling Wave Analysis (RCWA). After optimization, the strongest enhancement factor is found to be 9.7 for 514nm wavelength light. The theoretical results arc confirmed by angle-dependent reflectivity measurements and the experimental results are found to support the theory. A novel single slit structure employing surface plasmon polaritons (SPPs) for enhancing the electric field is studied. SPPs are first generated on a 50 nm thick metal film using attenuated total reflection coupling, and they are subsequently coupled to the cavity mode induced by the single slit. As a result, the field enhancement is found at least 3

  19. Metal Detectors.

    ERIC Educational Resources Information Center

    Harrington-Lueker, Donna

    1992-01-01

    Schools that count on metal detectors to stem the flow of weapons into the schools create a false sense of security. Recommendations include investing in personnel rather than hardware, cultivating the confidence of law-abiding students, and enforcing discipline. Metal detectors can be quite effective at afterschool events. (MLF)

  20. Investigation of radioactive noble gases distribution in atmosphere

    SciTech Connect

    Achkasov, S.K.; Duginets, G.A.; Krylov, A.Yu.

    1993-12-31

    This report describes two tasks pertaining to the study of radioactive noble gases in the atmosphere: research of global effects, and using the results of measurements of the concentrations in the atmosphere as a specific tool for control of environmental radiation condition near nuclear facilities.

  1. The Origin of Noble Gas Isotopic Heterogeneity in Icelandic Basalts

    NASA Technical Reports Server (NTRS)

    Dixon, E. T.; Honda, M.; McDougall, I.

    2001-01-01

    Two models for generation of heterogeneous He, Ne and Ar isotopic ratios in Icelandic basalts are evaluated using a mixing model and the observed noble gas elemental ratios in Icelandic basalts,Ocean island Basalt (OIBs) and Mid-Ocean Ridge Basalt (MORBs). Additional information is contained in the original extended abstract.

  2. Making A Noble-Metal-On-Metal-Oxide Catalyst

    NASA Technical Reports Server (NTRS)

    Miller, Irvin M.; Davis, Patricia P.; Upchurch, Billy T.

    1989-01-01

    Catalyst exhibits superior performance in oxidation of CO in CO2 lasers. Two-step process developed for preparing platinum- or palladium-on-tin-oxide catalyst for recombination of CO and O2, decomposition products that occur in high-voltage discharge region of closed-cycle CO2 laser. Process also applicable to other noble-metal/metal-oxide combinations.

  3. On the origin of noble gases in mantle plumes.

    PubMed

    Coltice, Nicolas; Ricard, Yanick

    2002-11-15

    The chemical differences between deep- and shallow-mantle sources of oceanic basalts provide evidence that several distinct components coexist within the Earth's mantle. Most of these components have been identified as recycled in origin. However, the noble-gas signature is still a matter of debate and questions the preservation of primitive regions in the convective mantle. We show that a model where the noble-gas signature observed in Hawaii and Iceland comes from a pristine homogeneous deep layer would imply a primitive (3)He content and (3)He/(22)Ne ratio that are very unlikely. On the contrary, mass balances show that the partly degassed peridotite of a marble-cake mantle can be the noble-gas end-member with an apparent 'primitive'-like composition. This component is mixed with recycled oceanic crust in different proportions in the plume sources and in the shallow mantle. A recycling model of the mantle, involving gravitational segregation of the oceanic crust at the bottom of the mantle, potentially satisfies trace-element as well as noble-gas constraints.

  4. Noble Gases in the Hamlet Meteorite (LL4)

    NASA Astrophysics Data System (ADS)

    Amari, S.; Sabe, Y.; Shiraishi, T.; Matsuda, J.

    2014-09-01

    We analyzed noble gases in a bulk sample and an HF-HCl residue of Hamlet (LL4). The Xe composition of the residue shows that no diamond is contained in the residue. The 20Ne/22Ne ratio of Hamlet Ne-Q has been determined to be 11.0 ± 0.5.

  5. A simple mercury vapor detector for geochemical prospecting

    USGS Publications Warehouse

    Vaughn, William W.

    1967-01-01

    The detector utilizes a large-volume atomic-absorption technique for quantitative determinations of mercury vapor thermally released from crushed rock. A quartz-enclosed noble-metal amalgamative stage, which is temperature controlled and is actuated by a radio-frequency induction heater, selectively traps the mercury and eliminates low-level contamination. As little as 1 part per billion of mercury can be detected in a 1-gram sample in a 1-minute analytical period.

  6. Impact degassing of water and noble gases from silicates

    NASA Technical Reports Server (NTRS)

    Azuma, S.; Hiyagon, H.; Iijima, Y.; Syono, Y.

    1994-01-01

    Previous shock experiments by Ahrens and his colleagues show that degassing of H2O and CO2 occurs at 8-65GPa from hydrous minerals such as serpentine. In early solar system, the impact degassing would have played an important part in the formation of primary-atmospheres of the terrestrial planets. However, degassing conditions of noble gases are not well-known because there are few experiments for them. We conducted some shock recovery experiments to investigate the degassing condition and to understand the degassing mechanisms of water and noble gases. We used natural richterites (Ri), amphibolites (Am), serpentines (Sep) and orthoclases (or) as target samples. These, except Sep, contain radiogenic noble gases such as (40)Ar. The samples were put in stainless steel containers, and were show by a rail gun at ISAS or single-stage powder guns at Nagoya or Tohoku University, Japan. We used two kinds of containers: 'open' type containers having a ventilating path for released volatiles for most of samples and 'closed' type ones for some samples for comparison. On Ri and Sep, we made shock experiments for pre-heated (at 400-500 C) and unheated targets, and for powdered and uncrushed samples. Water and noble gases were analyzed both for the recovered shocked samples and the unshocked original samples, and the fractions of the degassed volatiles were calculated by comparing them. Water content in the sample was analyzed by thermo-gravimetry. Noble gases were extracted by heating the samples under high vacuum and analyzed with a sector-type mass spectrometer.

  7. Impact degassing of water and noble gases from silicates

    NASA Astrophysics Data System (ADS)

    Azuma, S.; Hiyagon, H.; Iijima, Y.; Syono, Y.

    Previous shock experiments by Ahrens and his colleagues show that degassing of H2O and CO2 occurs at 8-65GPa from hydrous minerals such as serpentine. In early solar system, the impact degassing would have played an important part in the formation of primary-atmospheres of the terrestrial planets. However, degassing conditions of noble gases are not well-known because there are few experiments for them. We conducted some shock recovery experiments to investigate the degassing condition and to understand the degassing mechanisms of water and noble gases. We used natural richterites (Ri), amphibolites (Am), serpentines (Sep) and orthoclases (or) as target samples. These, except Sep, contain radiogenic noble gases such as (40)Ar. The samples were put in stainless steel containers, and were show by a rail gun at ISAS or single-stage powder guns at Nagoya or Tohoku University, Japan. We used two kinds of containers: 'open' type containers having a ventilating path for released volatiles for most of samples and 'closed' type ones for some samples for comparison. On Ri and Sep, we made shock experiments for pre-heated (at 400-500 C) and unheated targets, and for powdered and uncrushed samples. Water and noble gases were analyzed both for the recovered shocked samples and the unshocked original samples, and the fractions of the degassed volatiles were calculated by comparing them. Water content in the sample was analyzed by thermo-gravimetry. Noble gases were extracted by heating the samples under high vacuum and analyzed with a sector-type mass spectrometer.

  8. Noble Gas Signatures in Greenland - Tracing Glacial Meltwater Sources

    NASA Astrophysics Data System (ADS)

    Niu, Y.; Castro, M. C.; Hall, C. M.; Aciego, S.; Stevenson, E. I.; Arendt, C. A.

    2014-12-01

    This study is meant to explore the information noble gases can provide in glacial environments with respect to glacial meltwater sources, relative source contributions, water residence times, and spatial location where this glacial meltwater originates in the ice sheet. Ultimately, we seek to improve our understanding on the dynamics of these massive ice sheets, critical for the major role they play on climate change. This is possible due to the conservative nature of noble gases and temperature dependency of their concentrations in water in equilibrium with the atmosphere (ASW) allowing for calculation of noble gas temperatures (NGTs) and, under certain assumptions, estimation of the altitude at which glacial meltwater originated. In addition, crustally produced isotopes such as He accumulate in water over time, allowing for estimation of water residence times. Glacial meltwater samples were collected and analyzed for noble gas concentrations and isotopic ratios at five different locations in southern Greenland, between sea level and 1221 m. All samples are enriched in He with respect to ASW and are depleted in all other noble gases. Two patterns are apparent. The first one presents a relative Ar enrichment with respect to Ne, Kr, and Xe, a pattern first observed in high-altitude springs in the Galápagos Islands. The second one displays a mass-dependent pattern, a pattern first observed in Michigan rainwater samples. Most samples point to equilibration temperatures at ~0°C and altitudes between 1000 m and 2000 m, values which are consistent with both temperatures and elevations in Greenland. He concentrations vary between 1.1 and 7 times that of ASW and suggest glacial meltwater ages between ~170 and 1150 yrs, a result which is consistent with a preliminary tritium analysis. He isotopes point to surface (precipitation as snow and rainfall) contributions for most samples between ~60% and 90% with a ~10% - 40% crustal contribution from groundwater.

  9. Gaseous Detectors

    NASA Astrophysics Data System (ADS)

    Titov, Maxim

    Since long time, the compelling scientific goals of future high-energy physics experiments were a driving factor in the development of advanced detector technologies. A true innovation in detector instrumentation concepts came in 1968, with the development of a fully parallel readout for a large array of sensing elements - the Multi-Wire Proportional Chamber (MWPC), which earned Georges Charpak a Nobel prize in physics in 1992. Since that time radiation detection and imaging with fast gaseous detectors, capable of economically covering large detection volumes with low mass budget, have been playing an important role in many fields of physics. Advances in photolithography and microprocessing techniques in the chip industry during the past decade triggered a major transition in the field of gas detectors from wire structures to Micro-Pattern Gas Detector (MPGD) concepts, revolutionizing cell-size limitations for many gas detector applications. The high radiation resistance and excellent spatial and time resolution make them an invaluable tool to confront future detector challenges at the next generation of colliders. The design of the new micro-pattern devices appears suitable for industrial production. Novel structures where MPGDs are directly coupled to the CMOS pixel readout represent an exciting field allowing timing and charge measurements as well as precise spatial information in 3D. Originally developed for the high-energy physics, MPGD applications have expanded to nuclear physics, photon detection, astroparticle and neutrino physics, neutron detection, and medical imaging.

  10. Application of Two Phase (Liquid/Gas) Xenon Gamma-Camera for the Detection of Special Nuclear Material and PET Medical Imaging

    SciTech Connect

    McKinsey, Daniel Nicholas

    2013-08-27

    The McKinsey group at Yale has been awarded a grant from DTRA for the building of a Liquid Xenon Gamma Ray Color Camera (LXe-GRCC), which combines state-of-the-art detection of LXe scintillation light and time projection chamber (TPC) charge readout. The DTRA application requires a movable detector and hence only a single phase (liquid) xenon detector can be considered in this case. We propose to extend the DTRA project to applications that allow a two phase (liquid/gas) xenon TPC. This entails additional (yet minimal) hardware and extension of the research effort funded by DTRA. The two phase detector will have better energy and angular resolution. Such detectors will be useful for PET medical imaging and detection of special nuclear material in stationary applications (e.g. port of entry). The expertise of the UConn group in gas phase TPCs will enhance the capabilities of the Yale group and the synergy between the two groups will be very beneficial for this research project as well as the education and research projects of the two universities. The LXe technology to be used in this project has matured rapidly over the past few years, developed for use in detectors for nuclear physics and astrophysics. This technology may now be applied in a straightforward way to the imaging of gamma rays. According to detailed Monte Carlo simulations recently performed at Yale University, energy resolution of 1% and angular resolution of 3 degrees may be obtained for 1.0 MeV gamma rays, using existing technology. With further research and development, energy resolution of 0.5% and angular resolution of 1.3 degrees will be possible at 1.0 MeV. Because liquid xenon is a high density, high Z material, it is highly efficient for scattering and capturing gamma rays. In addition, this technology scales elegantly to large detector areas, with several square meter apertures possible. The Yale research group is highly experienced in the development and use of noble liquid detectors for

  11. Light noble gas dissolution into ring structure-bearing materials and lattice influences on noble gas recycling

    NASA Astrophysics Data System (ADS)

    Jackson, Colin R. M.; Parman, Stephen W.; Kelley, Simon P.; Cooper, Reid F.

    2015-06-01

    Light noble gas (He-Ne-Ar) solubility has been experimentally determined in a range of materials with six-member, tetrahedral ring structures: beryl, cordierite, tourmaline, antigorite, muscovite, F-phlogopite, actinolite, and pargasite. Helium solubility in these materials is relatively high, 4 × 10-10 to 3 × 10-7 mol g-1 bar-1, which is ∼100 to 100,000× greater than He solubility in olivine, pyroxene, or spinel. Helium solubility broadly correlates with the topology of ring structures within different minerals. Distinctive He-Ne-Ar solubility patterns are associated with the different ring structure topologies. Combined, these observations suggest ring structures have a strong influence on noble gas solubility in materials and could facilitate the recycling of noble gases, along with other volatiles (i.e., water, chlorine, and fluorine), into the mantle. Measurements of Ne and Ar solubility in antigorite, however, are highly variable and correlated with each other, suggesting multiple factors contribute the solubility of noble gases in serpentine-rich materials.

  12. Simultaneous quantitation of 14 active components in Yinchenhao decoction with an ultrahigh performance liquid chromatography-diode array detector: Method development and ingredient analysis of different commonly prepared samples.

    PubMed

    Yi, YaXiong; Zhang, Yong; Ding, Yue; Lu, Lu; Zhang, Tong; Zhao, Yuan; Xu, XiaoJun; Zhang, YuXin

    2016-11-01

    J. Sep. Sci. 2016, 39, 4147-4157 DOI: 10.1002/jssc.201600284 Yinchenhao decoction (YCHD) is a famous Chinese herbal formula recorded in the Shang Han Lun which was prescribed by Zhongjing Zhang during 150-219 AD. A novel quantitative analysis method was developed, based on ultrahigh performance liquid chromatography coupled with a diode array detector for the simultaneous determination of 14 main active components in Yinchenhao decoction. Furthermore, the method has been applied for compositional difference analysis of the 14 components in eight normal extraction samples of Yinchenhao decoction, with the aid of hierarchical clustering analysis and similarity analysis. The present research could help hospital, factory and lab choose the best way to make Yinchenhao decoction with better efficacy.

  13. Analysis of the influence of processing of stir-baking with glycyrrhizae on the main components of Euodiae Fructus by high-performance liquid chromatography with diode array detector.

    PubMed

    Hu, Jue; Wu, Xin; Cao, Gang; Chen, Xiaocheng

    2014-01-01

    Euodiae Fructus is one of the most commonly used Chinese herbs in China. Specifically, the crude Euodiae Fructus and its processed products of Gancao Zhi Pin are used clinically for the treatment of different diseases. In order to improve the quality control standard and evaluate the crude and processed Euodiae Fructus, in this study, a simple and sensitive high-performance liquid chromatography-diode array detector method was developed for the simultaneous determination of five major compounds in Euodiae Fructus. The results indicated that the five components had significant linear relation (r(2) ≥ 0.9997) between the peak area and the injected concentration. The average recoveries of the five components were in the range from 97.38% to 102.56%. Overall intra- and inter-day variations were less than 1.36%. The developed method can be applied to the intrinsic quality control of crude and processed Euodiae Fructus.

  14. Compact Solid State Terahertz Detectors

    DTIC Science & Technology

    2007-07-09

    bias voltages across the above temperature range. Two design, fabrication and optimisation cycles will be completed in 12 months. Each cycle will...measured the THz radiation-induced photocurrent in an in-plane geometry of the samples at liquid helium temperatures. The results are depicted in Fig...evaluated for each specific application geometry . Following on from this the noise equivalent power in the detectors at liquid helium temperatures is

  15. A solid phase microextraction coating based on ionic liquid sol-gel technique for determination of benzene, toluene, ethylbenzene and o-xylene in water samples using gas chromatography flame ionization detector.

    PubMed

    Sarafraz-Yazdi, Ali; Vatani, Hossein

    2013-07-26

    Ionic liquid mediated sol-gel sorbents for head-space solid phase microextraction (HS-SPME) were developed for the extraction of benzene, toluene, ethylbenzene and o-xylene (BTEX) compounds from water samples in ultra-trace levels. The analytes were subsequently analyzed with gas chromatography coupled to flame ionization detector (GC-FID). Three different coating fibers were prepared including: poly(dimethylsiloxane) (PDMS), coating prepared from poly(dimethylsiloxane) in the presence of ionic liquid as co-solvent and conditioned at a higher temperature than decomposition temperature of ionic liquid (PDMS-IL-HT) and coating prepared from poly(dimethylsiloxane) in the presence of ionic liquid as co-solvent and conditioned at a lower temperature than decomposition temperature of ionic liquid (PDMS-IL-LT). Prepared fibers demonstrate many advantages such as high thermal and chemical stabilities due to the chemical bonding of the coatings with the silanol groups on the fused-silica surface fiber. These fibers have shown long life time up to 180 extractions. The scanning electron micrographs of the fibers surfaces revealed that addition of ionic liquid into the sol solution during the sol-gel process increases the fiber coating thickness, affects the form of fiber structure and also leaves high pores in the fiber surface that cause high surface area and therefore increases sample capacity of the fibers. The important parameters that affect the extraction efficiency are desorption temperature and time, sample volume, extraction temperature, extraction time, stirring speed and salt effect. Therefore these factors were investigated and optimized. Under optimal conditions, the dynamic linear range with PDMS-IL-HT, PDMS and PDMS-IL-LT fibers were 0.3-200,000; 50-200,000 and 170-150,000pgmL(-1) and the detection limits (S/N=3) were 0.1-2 and 15-200 and 50-500pgmL(-1), and limit of quantifications (S/N=10) were 0.3-8 and 50-700 and 170-1800, respectively. The relative

  16. MS Detectors

    SciTech Connect

    Koppenaal, David W.; Barinaga, Charles J.; Denton, M Bonner B.; Sperline, Roger P.; Hieftje, Gary M.; Schilling, G. D.; Andrade, Francisco J.; Barnes IV., James H.

    2005-11-01

    Good eyesight is often taken for granted, a situation that everyone appreciates once vision begins to fade with age. New eyeglasses or contact lenses are traditional ways to improve vision, but recent new technology, i.e. LASIK laser eye surgery, provides a new and exciting means for marked vision restoration and improvement. In mass spectrometry, detectors are the 'eyes' of the MS instrument. These 'eyes' have also been taken for granted. New detectors and new technologies are likewise needed to correct, improve, and extend ion detection and hence, our 'chemical vision'. The purpose of this report is to review and assess current MS detector technology and to provide a glimpse towards future detector technologies. It is hoped that the report will also serve to motivate interest, prompt ideas, and inspire new visions for ion detection research.

  17. Ionic liquids in the synthesis of nanoobjects

    NASA Astrophysics Data System (ADS)

    Tarasova, Natalia P.; Smetannikov, Yurii V.; Zanin, A. A.

    2010-08-01

    Data on the usage of the novel green solvents, ionic liquids, in the synthesis of nanoobjects and their stabilization are considered. The information is structured according to the resulting products of the synthetic processes: nanoparticles of noble metals, nanoparticles of non-metals, nanoparticles of metal oxides and chalcogenides, nanocomposites, and highly dispersed polymers. The conclusion is made that the ionic liquids might determine the structure and the properties of the nanoobjects, thus opening new fundamental and technological horizons in nanochemistry.

  18. The DarkSide-50 outer detectors

    NASA Astrophysics Data System (ADS)

    Westerdale, S.; Agnes, P.; Agostino, L.; Albuquerque, I. F. M.; Alexander, T.; Alton, A. K.; Arisaka, K.; Back, H. O.; Baldin, B.; Biery, K.; Bonfini, G.; Bossa, M.; Bottino, B.; Brigatti, A.; Brodsky, J.; Budano, F.; Bussino, S.; Cadeddu, M.; Cadonati, L.; Cadoni, M.; Calaprice, F.; Canci, N.; Candela, A.; Cao, H.; Cariello, M.; Carlini, M.; Catalanotti, S.; Cavalcante, P.; Chepurnov, A.; Cocco, A. G.; Covone, G.; D'Angelo, D.; D'Incecco, M.; Davini, S.; De Cecco, S.; De Deo, M.; De Vincenzi, M.; Derbin, A.; Devoto, A.; Di Eusanio, F.; Di Pietro, G.; Edkins, E.; Empl, A.; Fan, A.; Fiorillo, G.; Fomenko, K.; Foster, G.; Franco, D.; Gabriele, F.; Galbiati, C.; Giganti, C.; Goretti, A. M.; Granato, F.; Grandi, L.; Gromov, M.; Guan, M.; Guardincerri, Y.; Hackett, B. R.; Herner, K. R.; Hungerford, E. V.; Aldo, Ianni; Andrea, Ianni; James, I.; Jollet, C.; Keeter, K.; Kendziora, C. L.; Kobychev, V.; Koh, G.; Korablev, D.; Korga, G.; Kubankin, A.; Li, X.; Lissia, M.; Lombardi, P.; Luitz, S.; Ma, Y.; Machulin, I. N.; Mandarano, A.; Mari, S. M.; Maricic, J.; Marini, L.; Martoff, C. J.; Meregaglia, A.; Meyers, P. D.; Miletic, T.; Milincic, R.; Montanari, D.; Monte, A.; Montuschi, M.; Monzani, M. E.; Mosteiro, P.; Mount, B. J.; Muratova, V. N.; Musico, P.; Napolitano, J.; Orsini, M.; Ortica, F.; Pagani, L.; Pallavicini, M.; Pantic, E.; Parmeggiano, S.; Pelczar, K.; Pelliccia, N.; Perasso, S.; Pocar, A.; Pordes, S.; Pugachev, D. A.; Qian, H.; Randle, K.; Ranucci, G.; Razeto, A.; Reinhold, B.; Renshaw, A. L.; Romani, A.; Rossi, B.; Rossi, N.; Rountree, S. D.; Sablone, D.; Saggese, P.; Saldanha, R.; Sands, W.; Sangiorgio, S.; Savarese, C.; Segreto, E.; Semenov, D. A.; Shields, E.; Singh, P. N.; DSkorokhvatov, M.; Smirnov, O.; Sotnikov, A.; Stanford, C.; Suvorov, Y.; Tartaglia, R.; Tatarowicz, J.; Testera, G.; Tonazzo, A.; Trinchese, P.; Unzhakov, E. V.; Vishneva, A.; Vogelaar, B.; Wada, M.; Walker, S.; Wang, H.; Wang, Y.; Watson, A. W.; Wilhelmi, J.; Wojcik, M. M.; Xiang, X.; Xu, J.; Yang, C.; Yoo, J.; Zavatarelli, S.; Zec, A.; Zhong, W.; Zhu, C.; Zuzel, G.; DarkSide Collaboration

    2016-05-01

    DarkSide-50 is a dark matter detection experiment searching for Weakly Interacting Massive Particles (WIMPs), in Gran Sasso National Laboratory. For experiments like DarkSide-50, neutrons are one of the primary backgrounds that can mimic WIMP signals. The experiment consists of three nested detectors: a liquid argon time projection chamber surrounded by two outer detectors. The outermost detector is a 10 m by 11 m cylindrical water Cherenkov detector with 80 PMTs, designed to provide shielding and muon vetoing. Inside the water Cherenkov detector is the 4 m diameter spherical boron-loaded liquid scintillator veto, with a cocktail of pseudocumene, trimethyl borate, and PPO wavelength shifter, designed to provide shielding, neutron vetoing, and in situ measurements of the TPC backgrounds. We present design and performance details of the DarkSide-50 outer detectors.

  19. MOCVD of multimetal and noble metal films

    NASA Astrophysics Data System (ADS)

    Endle, James Patrick

    2000-11-01

    Carbon content in TiN films produced with tetrakis(dimethylamino)titanium (TDMAT) and methylhydrazine or dimethylhydrazine can be controlled at or below 10% with a N/Ti ratio of ˜1.3 at growth temperatures between 573 and 723 K. Post-dosing either hydrazine on a CVD TiN film results in additional N-Ti bonds, indicating a surface reaction between the two precursors occurs. Co-dosing hydrazine-like compounds with larger alkyl ligands than methyl resulted in additional carbon incorporation in the TiN film. A growth system, consisting of a load lock and growth chamber, and a precursor pyrolysis system were designed and built to study metalorganic chemical vapor deposition. Addition of a bubbler and a direct liquid injection system allowed for the vaporization of solid and liquid precursors and solutions of multiple precursors. A precursor pyrolysis system was designed for high and low vapor pressure precursors and high carrier gas flow rates. The systems were used to study (Al,Ti)N and Ir film growth. (Al,Ti)N was used as a template to study the incorporation of elements into a multimetal chemical vapor deposited film using NH3 and a DLI solution of TDMAT and the tris(dimethylarnino)alane dimer (TDMAA) in toluene-NH 3 significantly decreases the decomposition temperature of both precursors. Carbon was reduced by increasing the NH3 partial pressure, and the Al incorporation was increased by increasing the TDMAA/TDMAT ratio in the DLI solution. Exposure to ambient resulted in significant oxygen incorporation and the removal of carbon and nitrogen from the (AI,Ti)N film. Conformal (AI,Ti)N films were produced at 450 K in the presence of NH3 and at 550 K without NH3. The role of O2 in Ir film growth was studied with the newly designed equipment. O2 significantly decreases the decomposition temperature of (MeCp)Ir(COD) below 425 K by preventing a carbonaceous build-up on the iridium film. By decreasing the oxygen partial pressure, the island nucleation and coalescence

  20. Understanding the SNO+ Detector

    SciTech Connect

    Kamdin, K.

    2015-03-24

    SNO+, a large liquid scintillator experiment, is the successor of the Sudbury Neutrino Observatory (SNO) experiment. The scintillator volume will be loaded with large quantities of 130Te, an isotope that undergoes double beta decay, in order to search for neutrinoless double beta decay. In addition to this search, SNO+ has a broad physics program due to its sensitivity to solar and supernova neutrinos, as well as reactor and geo anti-neutrinos. SNO+ can also place competitive limits on certain modes of invisible nucleon decay during its first phase. The detector is currently undergoing commissioning in preparation for its first phase, in which the detector is filled with ultra pure water. This will be followed by a pure scintillator phase, and then a Tellurium-loaded scintillator phase to search for neutrinoless double beta decay. Here we present the work done to model detector aging, which was first observed during SNO. The aging was found to reduce the optical response of the detector. We also describe early results from electronics calibration of SNO+.

  1. Understanding the SNO+ Detector

    DOE PAGES

    Kamdin, K.

    2015-03-24

    SNO+, a large liquid scintillator experiment, is the successor of the Sudbury Neutrino Observatory (SNO) experiment. The scintillator volume will be loaded with large quantities of 130Te, an isotope that undergoes double beta decay, in order to search for neutrinoless double beta decay. In addition to this search, SNO+ has a broad physics program due to its sensitivity to solar and supernova neutrinos, as well as reactor and geo anti-neutrinos. SNO+ can also place competitive limits on certain modes of invisible nucleon decay during its first phase. The detector is currently undergoing commissioning in preparation for its first phase, inmore » which the detector is filled with ultra pure water. This will be followed by a pure scintillator phase, and then a Tellurium-loaded scintillator phase to search for neutrinoless double beta decay. Here we present the work done to model detector aging, which was first observed during SNO. The aging was found to reduce the optical response of the detector. We also describe early results from electronics calibration of SNO+.« less

  2. The Watchman Detector Design

    NASA Astrophysics Data System (ADS)

    Dazeley, Steven

    2014-03-01

    The Watchman collaboration is proposing a kiloton scale antineutrino detector of reactor-based antineutrinos for non-proliferation purposes. As an added bonus the detector will also have the capability to search for evidence of sterile neutrino oscillation, super-nova antineutrinos and, in a second phase, measure the neutrino mass hierarchy. Despite that fact that KamLAND demonstrated the feasibility of kiloton scale, long distance antineutrino detection with liquid scintillator, similar detectors at the megaton scale remain problematic for environmental, cost and light attenuation reasons. Water, with gadolinium added for neutron sensitivity, may be the detection medium of choice if its efficiency can be shown to be competitive with scintillator. The goal of the Watchman project, therefore, is to demonstrate medium distance reactor antineutrino detection, and thus demonstrate the feasibility of moving to water-based megaton scale antineutrino detectors in the future. In this talk I will describe the scope of the experiment, the physics and engineering challenges involved, the proposed design and the predicted performance of the experimental non-proliferation and high-energy physics program. Lawrence Livermore National Laboratory is operated by Lawrence Livermore National Security, LLC, for the U.S. Department of Energy, National Nuclear Security Administration under Contract DE-AC52-07NA27344. Release number LLNL-ABS-648381.

  3. Understanding the SNO+ Detector

    NASA Astrophysics Data System (ADS)

    Kamdin, K.

    SNO+, a large liquid scintillator experiment, is the successor of the Sudbury Neutrino Observatory (SNO) experiment. The scintillator volume will be loaded with large quantities of 130Te, an isotope that undergoes double beta decay, in order to search for neutrinoless double beta decay. In addition to this search, SNO+ has a broad physics program due to its sensitivity to solar and supernova neutrinos, as well as reactor and geo anti-neutrinos. SNO+ can also place competitive limits on certain modes of invisible nucleon decay during its first phase. The detector is currently undergoing commissioning in preparation for its first phase, in which the detector is filled with ultra pure water. This will be followed by a pure scintillator phase, and then a Tellurium-loaded scintillator phase to search for neutrinoless double beta decay. Here we present the work done to model detector aging, which was first observed during SNO. The aging was found to reduce the optical response of the detector. We also describe early results from electronics calibration of SNO+.

  4. Photon detectors

    SciTech Connect

    Va`vra, J.

    1995-10-01

    J. Seguinot and T. Ypsilantis have recently described the theory and history of Ring Imaging Cherenkov (RICH) detectors. In this paper, I will expand on these excellent review papers, by covering the various photon detector designs in greater detail, and by including discussion of mistakes made, and detector problems encountered, along the way. Photon detectors are among the most difficult devices used in physics experiments, because they must achieve high efficiency for photon transport and for the detection of single photo-electrons. For gaseous devices, this requires the correct choice of gas gain in order to prevent breakdown and wire aging, together with the use of low noise electronics having the maximum possible amplification. In addition, the detector must be constructed of materials which resist corrosion due to photosensitive materials such as, the detector enclosure must be tightly sealed in order to prevent oxygen leaks, etc. The most critical step is the selection of the photocathode material. Typically, a choice must be made between a solid (CsI) or gaseous photocathode (TMAE, TEA). A conservative approach favors a gaseous photocathode, since it is continuously being replaced by flushing, and permits the photon detectors to be easily serviced (the air sensitive photocathode can be removed at any time). In addition, it can be argued that we now know how to handle TMAE, which, as is generally accepted, is the best photocathode material available as far as quantum efficiency is concerned. However, it is a very fragile molecule, and therefore its use may result in relatively fast wire aging. A possible alternative is TEA, which, in the early days, was rejected because it requires expensive CaF{sub 2} windows, which could be contaminated easily in the region of 8.3 eV and thus lose their UV transmission.

  5. Perspectives of hyperpolarized noble gas MRI beyond 3He

    NASA Astrophysics Data System (ADS)

    Lilburn, David M. L.; Pavlovskaya, Galina E.; Meersmann, Thomas

    2013-04-01

    Nuclear Magnetic Resonance (NMR) studies with hyperpolarized (hp) noble gases are at an exciting interface between physics, chemistry, materials science and biomedical sciences. This paper intends to provide a brief overview and outlook of magnetic resonance imaging (MRI) with hp noble gases other than hp 3He. A particular focus are the many intriguing experiments with 129Xe, some of which have already matured to useful MRI protocols, while others display high potential for future MRI applications. Quite naturally for MRI applications the major usage so far has been for biomedical research but perspectives for engineering and materials science studies are also provided. In addition, the prospects for surface sensitive contrast with hp 83Kr MRI is discussed.

  6. Nuclear monitoring by nonradioactive noble gas sampling and analysis

    SciTech Connect

    Fearey, B.L.; Nakhleh, C.W.; Stanbro, W.D.

    1997-10-01

    This is the final report of a two-year, Laboratory Directed Research and Development (LDRD) project at the Los Alamos National Laboratory (LANL). The perceived importance of measuring the xenon and krypton isotopics of nuclear activities has increased substantially in recent years. We have performed a systems analysis and theoretical simulation of the production, atmospheric dispersion, and isotopic abundances of noble-gas fission products, addressing several questions of interest, including: the relative isotopic variation as a function of nuclear fuel composition, reactor operational history, reactor type, distance from stack, and ambient meteorological conditions. Of particular importance in this analysis was the question of back-calculating process parameters of interest given noble-gas isotopic data. An analysis of the effect of measurement uncertainties was also performed. The results of these analyses indicate that this monitoring concept should be experimentally feasible.

  7. Fullerenes: an extraterrestrial carbon carrier phase for noble gases.

    PubMed

    Becker, L; Poreda, R J; Bunch, T E

    2000-03-28

    In this work, we report on the discovery of naturally occurring fullerenes (C60 to C400) in the Allende and Murchison meteorites and some sediment samples from the 65 million-year-old Cretaceous/Tertiary boundary layer (KTB). Unlike the other pure forms of carbon (diamond and graphite), fullerenes are extractable in an organic solvent (e.g., toluene or 1,2,4-trichlorobenzene). The recognition of this unique property led to the detection and isolation of the higher fullerenes in the Kratschmer/Huffmann arc evaporated graphite soot and in the carbon material in the meteorite and impact deposits. By further exploiting the unique ability of the fullerene cage structure to encapsulate and retain noble gases, we have determined that both the Allende and Murchison fullerenes and the KTB fullerenes contain trapped noble gases with ratios that can only be described as extraterrestrial in origin.

  8. Identification of potential protein markers of noble rot infected grapes.

    PubMed

    Lorenzini, Marilinda; Millioni, Renato; Franchin, Cinzia; Zapparoli, Giacomo; Arrigoni, Giorgio; Simonato, Barbara

    2015-07-15

    The evaluation of Botrytis cinerea as noble rot on withered grapes is of great importance to predict the wine sensory/organoleptic properties and to manage the winemaking process of Amarone, a passito dry red wine. This report describes the first proteomic analysis of grapes infected by noble rot under withering conditions to identify possible markers of fungal infection. 2-D gel electrophoresis revealed that protein profiles of infected and not infected grape samples are significantly different in terms of number of spots and relative abundance. Protein identification by MS analysis allowed to identify only in infected berries proteins of B. cinerea that represent potential markers of the presence of the fungus in the withered grapes.

  9. Noble Metal-Iron Oxide Hybrid Nanomaterials: Emerging Applications.

    PubMed

    Leung, Ken Cham-Fai; Xuan, Shouhu

    2016-02-01

    This account provides an overview of current research activities that focus on the synthesis and applications of nanomaterials from noble metal (e.g., Au, Ag, Pd) and iron oxide (Fe3O4) hybrids. An introduction to the synthetic strategies that have been developed for generating M-Fe3O4 nanomaterials with different novel structures is presented. Surface functionalization and bioconjugation of these hybrid nanoparticles and nanocomposites are also reviewed. The utilization of the advantageous properties of both noble metals and iron oxide for a variety of applications, such as theranostics, gene delivery, biosensing, cell sorting, bioseparation, and catalysis, is discussed and highlighted. Finally, future trends and perspectives of these sophisticated nanocomposites are outlined. The fundamental requirements underpinning the effective preparation of M-Fex Oy hybrid nanomaterials shed light on the future development of heterogeneous catalysts, nanotheranostics, nanomedicines, and other chemical technologies.

  10. NOBLE GAS PRODUCTION FROM MERCURY SPALLATION AT SNS

    SciTech Connect

    DeVore, Joe R; Lu, Wei; Schwahn, Scott O

    2013-01-01

    Calculations for predicting the distribution of the products of spallation reactions between high energy protons and target materials are well developed and are used for design and operational applications in many projects both within DOE and in other arenas. These calculations are based on theory and limited experimental data that verifies rates of production of some spallation products exist. At the Spallation Neutron Source, a helium stream from the mercury target flows through a system to remove radioactivity from this mercury target offgas. The operation of this system offers a window through which the production of noble gases from mercury spallation by protons may be observed. This paper describes studies designed to measure the production rates of twelve noble gas isotopes within the Spallation Neutron Source mercury target.

  11. Fullerenes: An extraterrestrial carbon carrier phase for noble gases

    PubMed Central

    Becker, Luann; Poreda, Robert J.; Bunch, Ted E.

    2000-01-01

    In this work, we report on the discovery of naturally occurring fullerenes (C60 to C400) in the Allende and Murchison meteorites and some sediment samples from the 65 million-year-old Cretaceous/Tertiary boundary layer (KTB). Unlike the other pure forms of carbon (diamond and graphite), fullerenes are extractable in an organic solvent (e.g., toluene or 1,2,4-trichlorobenzene). The recognition of this unique property led to the detection and isolation of the higher fullerenes in the Kratschmer/Huffmann arc evaporated graphite soot and in the carbon material in the meteorite and impact deposits. By further exploiting the unique ability of the fullerene cage structure to encapsulate and retain noble gases, we have determined that both the Allende and Murchison fullerenes and the KTB fullerenes contain trapped noble gases with ratios that can only be described as extraterrestrial in origin. PMID:10725367

  12. Recent Experimental Advances to Determine (noble) Gases in Waters

    NASA Astrophysics Data System (ADS)

    Kipfer, R.; Brennwald, M. S.; Huxol, S.; Mächler, L.; Maden, C.; Vogel, N.; Tomonaga, Y.

    2013-12-01

    In aquatic systems noble gases, radon, and bio-geochemically conservative transient trace gases (SF6, CFCs) are frequently applied to determine water residence times and to reconstruct past environmental and climatic conditions. Recent experimental breakthroughs now enable ● to apply the well-established concepts of terrestrial noble gas geochemistry in waters to the minute water amounts stored in sediment pore space and in fluid inclusions (A), ● to determine gas exchange processes on the bio-geochemical relevant time scales of minutes - hours (B), and ● to separate diffusive and advective gas transport in soil air (C). A. Noble-gas analysis in water samples (< 1 g) facilitates determining the solute transport in the pore space and identifying the origin of bio- and geogenic fluids in (un) consolidated sediments [1]. Advanced techniques that combine crushing and sieving speleothem samples in ultra-high-vacuum to a specific grain size allow to separate air and water-bearing fluid inclusions and thus enables noble-gas-based reconstruction of environmental conditions from water masses as small as 1mg [2]. B. The coupling of noble gas analysis with approaches of gas chromatography permits combined analysis of noble gases and other gases species (e.g., SF6, CFCs, O2, N2) from a single water sample. The new method substantially improves ground water dating by SF6 and CFCs as excess air is quantified from the same sample and hence can adequately be corrected for [3]. Portable membrane-inlet mass spectrometers enable the quasi-continuous and real-time analysis of noble gases and other dissolved gases directly in the field, allowing, for instance, quantification of O2 turnover rates on small time scales [4]. C. New technical developments perfect 222Rn analysis in water by the synchronous the determination of the short-lived 220Rn. The combined 220,222Rn analysis sheds light on the emanation behaviour of radon by identifying soil water content to be the crucial

  13. Quantification of phospholipids in infant formula and growing up milk by high-performance liquid chromatography with evaporative light scattering detector.

    PubMed

    Braun, Marcel; Flück, Brigitte; Cotting, Claudia; Monard, Florence; Giuffrida, Francesca

    2010-01-01

    Phospholipids (PLs) are well known for their excellent emulsifier properties and more recently for their biological functions, such as cell signing, brain development, immune function, heart health, and cancer prevention, besides their physiological role in membrane composition. In dairy products, PLs represent 0.2-1% of milk fat. The milk PLs comprise phosphatidylcholine (PC), phosphatidylethanolamine (PE), and sphingomyelin (SPH) as the major compounds; phosphatidylinositol and phosphatidylserine are minor PLs. A new generation of dairy products claiming PL family content, such as SPH, is being produced; therefore, a validated method for quantifying PL families in dairy products is needed. In this study, an HPLC-evaporative light scattering detector method to quantify the most abundant milk PL families, i.e., PC, PE, and SPH, in infant formula and growing up milk was developed and validated.

  14. DETECTORS AND EXPERIMENTAL METHODS: Measurement of the response function and the detection efficiency of an organic liquid scintillator for neutrons between 1 and 30 MeV

    NASA Astrophysics Data System (ADS)

    Huang, Han-Xiong; Ruan, Xi-Chao; Chen, Guo-Chang; Zhou, Zu-Ying; Li, Xia; Bao, Jie; Nie, Yang-Bo; Zhong, Qi-Ping

    2009-08-01

    The light output function of a varphi50.8 mm × 50.8 mm BC501A scintillation detector was measured in the neutron energy region of 1 to 30 MeV by fitting the pulse height (PH) spectra for neutrons with the simulations from the NRESP code at the edge range. Using the new light output function, the neutron detection efficiency was determined with two Monte-Carlo codes, NEFF and SCINFUL. The calculated efficiency was corrected by comparing the simulated PH spectra with the measured ones. The determined efficiency was verified at the near threshold region and normalized with a Proton-Recoil-Telescope (PRT) at the 8-14 MeV energy region.

  15. Column Liquid Chromatography.

    ERIC Educational Resources Information Center

    Majors, Ronald E.; And Others

    1984-01-01

    Reviews literature covering developments of column liquid chromatography during 1982-83. Areas considered include: books and reviews; general theory; columns; instrumentation; detectors; automation and data handling; multidimensional chromatographic and column switching techniques; liquid-solid chromatography; normal bonded-phase, reversed-phase,…

  16. Noble Gas Analysis in the Quest to Find "Regolithic" Howardites

    NASA Technical Reports Server (NTRS)

    Cartwright, Julia A.; Hermann, S.; Herrin, J.; Mittlefehldt, D. W.; Ott, U.

    2011-01-01

    The howardite meteorites consist of approximately 200 polymict breccias of eucrite (basaltic) and diogenite (orthopyroxenitic) material (collectively, the HED group) that originate from the asteroid belt. Infrared reflectance spectroscopy of asteroids and laboratory studies of HEDs have indicated that the asteroid 4-Vesta is the likely parent body, and the partially-demolished south pole may be the source region. Asteroid regolith formation processes may be responsible for a number of observed petrological features including impact melt clasts, reworked clasts and mosaisicm. We have identified such features in a study of 30 howardites and polymict eucrites, and developed a regolith grading scheme based on petrology. However, the true regolithic nature of the howardite suite is not well defined, and previous research has suggested correlations between Ni contents of 300 - 1200 micron / g, a minimal variation in Al2O3 content around 8-9 wt% and the presence of solar wind noble gases are key hallmarks of an ancient regolith on Vesta . Through combined petrological, compositional and noble gas research, we aim to better understand howardite petrological diversity, regolith formation processes on parent asteroids, and to establish what defines a truly "regolithic" howardite. Our research will play an integral part in the interpretation of data gathered by the Dawn mission. Here we report the preliminary results from our noble gas analyses of four howardites: LEW 85313, EET 99408, MET 96500 and PCA 02066. Bulk major element compositional data have been collected, further petrological data for the HED group are reported by our colleagues, whilst trace-element analyses are underway. Our work will investigate the extent of whether previously described Ni, Al2O3 and noble gas characteristics are in fact indicative of a "regolithic" howardite.

  17. Stellar condensates in meteorites - Isotopic evidence from noble gases

    NASA Technical Reports Server (NTRS)

    Lewis, R. S.; Alaerts, L.; Matsuda, J.-I.; Anders, E.

    1979-01-01

    The Murchison carbonaceous chondrite contains three isotopically anomalous noble-gas components of apparently presolar origin: two kinds of Ne-E, (Ne-20)/(Ne-22) less than 0.6, and s-process Kr + Xe (enriched in the even isotopes 82, 84, 86, 128, 130, 132). Their carriers are tentatively identified as spinel and two carbonaceous phases, the principal high-temperature stellar condensates at low and high C/O ratios, respectively.

  18. Low-field MRI of laser polarized noble gas

    NASA Technical Reports Server (NTRS)

    Tseng, C. H.; Wong, G. P.; Pomeroy, V. R.; Mair, R. W.; Hinton, D. P.; Hoffmann, D.; Stoner, R. E.; Hersman, F. W.; Cory, D. G.; Walsworth, R. L.

    1998-01-01

    NMR images of laser polarized 3He gas were obtained at 21 G using a simple, homebuilt instrument. At such low fields magnetic resonance imaging (MRI) of thermally polarized samples (e.g., water) is not practical. Low-field noble gas MRI has novel scientific, engineering, and medical applications. Examples include portable systems for diagnosis of lung disease, as well as imaging of voids in porous media and within metallic systems.

  19. Photoionization of noble-gas atoms by ultrashort electromagnetic pulses

    SciTech Connect

    Astapenko, V. A. Svita, S. Yu.

    2014-11-15

    The photoionization of atoms of noble gases (Ar, Kr, and Xe) by ultrashort electromagnetic pulses of a corrected Gaussian shape is studied theoretically. Computations are performed in the context of perturbation theory using a simple expression for the total probability of photoionization of an atom by electromagnetic pulses. The features of this process are revealed and analyzed for various ranges of the parameters of the problem.

  20. High temperature, oxidation resistant noble metal-Al alloy thermocouple

    NASA Technical Reports Server (NTRS)

    Smialek, James L. (Inventor); Gedwill, Michael G. (Inventor)

    1994-01-01

    A thermocouple is disclosed. The thermocouple is comprised of an electropositive leg formed of a noble metal-Al alloy and an electronegative leg electrically joined to form a thermocouple junction. The thermocouple provides for accurate and reproducible measurement of high temperatures (600 - 1300 C) in inert, oxidizing or reducing environments, gases, or vacuum. Furthermore, the thermocouple circumvents the need for expensive, strategic precious metals such as rhodium as a constituent component. Selective oxidation of rhodium is also thereby precluded.

  1. Diverging effects of isotopic fractionation upon molecular diffusion of noble gases in water: mechanistic insights through ab initio molecular dynamics simulations.

    PubMed

    Pinto de Magalhães, Halua; Brennwald, Matthias S; Kipfer, Rolf

    2017-02-10

    Atmospheric noble gases are routinely used as natural tracers to analyze gas transfer processes in aquatic systems. Their isotopic ratios can be employed to discriminate between different physical transport mechanisms by comparison to the unfractionated atmospheric isotope composition. In many applications of aquatic systems molecular diffusion was thought to cause a mass dependent fractionation of noble gases and their isotopes according to the square root ratio of their masses. However, recent experiments focusing on isotopic fractionation within a single element challenged this broadly accepted assumption. The determined fractionation factors of Ne, Ar, Kr and Xe isotopes revealed that only Ar follows the prediction of the so-called square root relation, whereas within the Ne, Kr and Xe elements no mass-dependence was found. The reason for this unexpected divergence of Ar is not yet understood. The aim of our computational exercise is to establish the molecular-resolved mechanisms behind molecular diffusion of noble gases in water. We make the hypothesis that weak intermolecular interactions are relevant for the dynamical properties of noble gases dissolved in water. Therefore, we used ab initio molecular dynamics to explicitly account for the electronic degrees of freedom. Depending on the size and polarizability of the hydrophobic particles such as noble gases, their motion in dense and polar liquids like water is subject to different diffusive regimes: the inter-cavity hopping mechanism of small particles (He, Ne) breaks down if a critical particle size achieved. For the case of large particles (Kr, Xe), the motion through the water solvent is governed by mass-independent viscous friction leading to hydrodynamical diffusion. Finally, Ar falls in between the two diffusive regimes, where particle dispersion is propagated at the molecular collision time scale of the surrounding water molecules.

  2. Intruder Detector

    NASA Technical Reports Server (NTRS)

    1978-01-01

    The shadowy prowler is attempting a break-in, unaware that his presence has already been detected and reported by the device in the lower left corner of the photo. It is part of a three-element ntruder Detecti on System developed by NASA's Ames Research Center from technology acquired in the Apollo lunar exploration program. Apollo astronauts left behind on the moon small portable seismic (shock) detectors to record subsurface vibrations and transmit to Earth data on the moon's density and thickness. A similar seismic detector is the key component of the lntruder Detection System. Encased in a stainless steel tube, the detector is implanted in the ground outside the facility being protected-home, bank, industrial or other facilities. The vibration-sensing detector picks up the footstep of anyone within a preset range. The detector is connected by cable to the transmitter, which relays the warning to a portable radio receiver. The radio alerts plant guards or home occupants by emitting an audible tone burst for each footstep.

  3. Pyroelectric detectors

    NASA Technical Reports Server (NTRS)

    Haller, Eugene E.; Beeman, Jeffrey; Hansen, William L.; Hubbard, G. Scott; Mcmurray, Robert E., Jr.

    1990-01-01

    The multi-agency, long-term Global Change programs, and specifically NASA's Earth Observing system, will require some new and advanced photon detector technology which must be specifically tailored for long-term stability, broad spectral range, cooling constraints, and other parameters. Whereas MCT and GaAs alloy based photovoltaic detectors and detector arrays reach most impressive results to wavelengths as long as 12 microns when cooled to below 70 K, other materials, such as ferroelectrics and pyroelectrics, appear to offer special opportunities beyond 12 microns and above 70 K. These materials have found very broad use in a wide variety of room temperature applications. Little is known about these classes of materials at sub-room temperatures and no photon detector results have been reported. From the limited information available, researchers conclude that the room temperature values of D asterisk greater than or equal to 10(exp 9) cm Hz(exp 1/2)/W may be improved by one to two orders of magnitude upon cooling to temperatures around 70 K. Improvements of up to one order of magnitude appear feasible for temperatures achievable by passive cooling. The flat detector response over a wavelength range reaching from the visible to beyond 50 microns, which is an intrinsic advantage of bolometric devices, makes for easy calibration. The fact that these materials have been developed for reduced temperature applications makes ferro- and pyroelectric materials most attractive candidates for serious exploration.

  4. Possible solar noble-gas component in Hawaiian basalts

    USGS Publications Warehouse

    Honda, M.; McDougall, I.; Patterson, D.B.; Doulgeris, A.; Clague, D.A.

    1991-01-01

    THE noble-gas elemental and isotopic composition in the Earth is significantly different from that of the present atmosphere, and provides an important clue to the origin and history of the Earth and its atmosphere. Possible candidates for the noble-gas composition of the primordial Earth include a solar-like component, a planetary-like component (as observed in primitive meteorites) and a component similar in composition to the present atmosphere. In an attempt to identify the contributions of such components, we have measured isotope ratios of helium and neon in fresh basaltic glasses dredged from Loihi seamount and the East Rift Zone of Kilauea1-3. We find a systematic enrichment in 20Ne and 21Ne relative to 22Ne, compared with atmospheric neon. The helium and neon isotope signatures observed in our samples can be explained by mixing of solar, present atmospheric, radiogenic and nucleogenic components. These data suggest that the noble-gas isotopic composition of the mantle source of the Hawaiian plume is different from that of the present atmosphere, and that it includes a significant solar-like component. We infer that this component was acquired during the formation of the Earth.

  5. Noble gas encapsulation: clathrate hydrates and their HF doped analogues.

    PubMed

    Mondal, Sukanta; Chattaraj, Pratim Kumar

    2014-09-07

    The significance of clathrate hydrates lies in their ability to encapsulate a vast range of inert gases. Although the natural abundance of a few noble gases (Kr and Xe) is poor their hydrates are generally abundant. It has already been reported that HF doping enhances the stability of hydrogen hydrates and methane hydrates, which prompted us to perform a model study on helium, neon and argon hydrates with their HF doped analogues. For this purpose 5(12), 5(12)6(8) and their HF doped analogues are taken as the model clathrate hydrates, which are among the building blocks of sI, sII and sH types of clathrate hydrate crystals. We use the dispersion corrected and gradient corrected hybrid density functional theory for the calculation of thermodynamic parameters as well as conceptual density functional theory based reactivity descriptors. The method of the ab initio molecular dynamics (AIMD) simulation is used through atom centered density matrix propagation (ADMP) techniques to envisage the structural behaviour of different noble gas hydrates on a 500 fs timescale. Electron density analysis is carried out to understand the nature of Ng-OH2, Ng-FH and Ng-Ng interactions. The current results noticeably demonstrate that the noble gas (He, Ne, and Ar) encapsulation ability of 5(12), 5(12)6(8) and their HF doped analogues is thermodynamically favourable.

  6. Heuristic overlap-exchange model of noble gas chemical shifts

    NASA Astrophysics Data System (ADS)

    Adrian, Frank J.

    2004-05-01

    It is now generally recognized that overlap-exchange interactions are the primary cause of the medium-dependent magnetic shielding (chemical shift) in all noble gases except helium, although the attractive electrostatic-dispersion (van der Waals) interactions play an indirect role in determining the penetration of the interacting species into the repulsive overlap-exchange region. The short-range nature of these overlap-exchange interactions, combined with the fact that they often can be approximated by simple functions of the overlap of the wave functions of the interacting species, suggests a useful semiempirical model of these chemical shifts. In it the total shielding is the sum of shieldings due to pairwise interactions of the noble gas atom with the individual atoms of the medium, with the "atomic" shielding terms either estimated by simple functions of the atomic overlap integrals averaged over their Boltzmann-weighted separations, or determined by fits to experimental data in systems whose complexity makes the former procedure impractical. Results for 129Xe chemical shifts in the noble gases and in a variety of molecular and condensed systems, including families of n-alkanes, straight-chain alcohols, and the endohedral compounds Xe@C60 and Xe@C70 are encouraging for the applicability of the model to systems of technical and biomedical interest.

  7. MAMA Detector

    NASA Technical Reports Server (NTRS)

    Bowyer, Stuart

    1998-01-01

    Work carried out under this grant led to fundamental discoveries and over one hundred publications in the scientific literature. Fundamental developments in instrumentation were made including all the instrumentation on the EUVE satellite, the invention of a whole new type of grazing instrument spectrometer and the development of fundamentally new photon counting detectors including the Wedge and Strip used on EUVE and many other missions and the Time Delay detector used on OREFUS and FUSE. The Wedge and Strip and Time Delay detectors were developed under this grant for less than two million dollars and have been used in numerous missions most recently for the FUSE mission. In addition, a fundamentally new type of diffuse spectrometer has been developed under this grant which has been used in instrumentation on the MMSAT spacecraft and the Lewis spacecraft. Plans are underway to use this instrumentation on several other missions as well.

  8. PHASE DETECTOR

    DOEpatents

    Kippenhan, D.O.

    1959-09-01

    A phase detector circuit is described for use at very high frequencies of the order of 50 megacycles. The detector circuit includes a pair of rectifiers inverted relative to each other. One voltage to be compared is applied to the two rectifiers in phase opposition and the other voltage to be compared is commonly applied to the two rectifiers. The two result:ng d-c voltages derived from the rectifiers are combined in phase opposition to produce a single d-c voltage having amplitude and polarity characteristics dependent upon the phase relation between the signals to be compared. Principal novelty resides in the employment of a half-wave transmission line to derive the phase opposing signals from the first voltage to be compared for application to the two rectifiers in place of the transformer commonly utilized for such purpose in phase detector circuits for operation at lower frequency.

  9. Hydrogen detector

    DOEpatents

    Kanegae, Naomichi; Ikemoto, Ichiro

    1980-01-01

    A hydrogen detector of the type in which the interior of the detector is partitioned by a metal membrane into a fluid section and a vacuum section. Two units of the metal membrane are provided and vacuum pipes are provided independently in connection to the respective units of the metal membrane. One of the vacuum pipes is connected to a vacuum gauge for static equilibrium operation while the other vacuum pipe is connected to an ion pump or a set of an ion pump and a vacuum gauge both designed for dynamic equilibrium operation.

  10. Microwave detector

    SciTech Connect

    Meldner, H.W.; Cusson, R.Y.; Johnson, R.M.

    1986-12-02

    A detector is described for measuring the envelope shape of a microwave pulse comprised of high-frequency oscillations, the detector comprising: a B-dot loop linking the magnetic field of the microwave pulse; a biased ferrite, that produces a magnetization field flux that links the B-dot loop. The ferrite is positioned within the B-dot loop so that the magnetic field of the microwave pulse interacts with the ferrite and thereby participates in the formation of the magnetization field flux; and high-frequency insensitive means for measuring electric voltage or current induced in the B-dot loop.

  11. Microwave detector

    DOEpatents

    Meldner, H.W.; Cusson, R.Y.; Johnson, R.M.

    1985-02-08

    A microwave detector is provided for measuring the envelope shape of a microwave pulse comprised of high-frequency oscillations. A biased ferrite produces a magnetization field flux that links a B-dot loop. The magnetic field of the microwave pulse participates in the formation of the magnetization field flux. High-frequency insensitive means are provided for measuring electric voltage or current induced in the B-dot loop. The recorded output of the detector is proportional to the time derivative of the square of the envelope shape of the microwave pulse.

  12. Microwave detector

    DOEpatents

    Meldner, Heiner W.; Cusson, Ronald Y.; Johnson, Ray M.

    1986-01-01

    A microwave detector (10) is provided for measuring the envelope shape of a microwave pulse comprised of high-frequency oscillations. A biased ferrite (26, 28) produces a magnetization field flux that links a B-dot loop (16, 20). The magnetic field of the microwave pulse participates in the formation of the magnetization field flux. High-frequency insensitive means (18, 22) are provided for measuring electric voltage or current induced in the B-dot loop. The recorded output of the detector is proportional to the time derivative of the square of the envelope shape of the microwave pulse.

  13. Silicon Detectors

    NASA Astrophysics Data System (ADS)

    Sadrozinski, Hartmut

    2014-03-01

    The use of silicon detectors has experienced an exponential growth in accelerator and space based experiments, similar to trends in the semiconductor industry as a whole, usually paraphrased as ``Moore's Law.'' Some of the essentials for this phenomenon will be presented, together with examples of the exciting science results which it enabled. With the establishment of a ``semiconductor culture'' in universities and laboratories around the world, an increased understanding of the sensors results in thinner, faster, more radiation-resistant detectors, spawning an amazing wealth of new technologies and applications, which will be the main subject of the presentation.

  14. Rapid method for the determination of non-steroidal anti-inflammatory drugs in animal tissue by liquid chromatography-mass spectrometry with ion-trap detector.

    PubMed

    Igualada, Carmen; Moragues, Francisco; Pitarch, Jorge

    2007-03-14

    A rapid and new liquid chromatography-mass spectrometry with ion-trap detection method for the determination of meloxicam (MLX), flunixin meglumine (FLU), carprofen (CPF), and tolfenamic acid (TOLF) in animal tissue is described. MRLs between 10 and 500 microg kg(-1) in muscle and between 65 and 1000 microg kg(-1) in liver, from different animal species have been established in the EU for these compounds. After chemical hydrolysis, an organic extraction from homogenised tissue was performed. Final extract was injected in a liquid chromatograph with an ion-trap mass spectrometer with electrospray interface. Four identification points (one precursor and two product ions) and a minimum of one ion ratio was monitored for each compound. For quantitative purposes flunixin-D3 (FLU-D3) was used as internal standard. The method was validated using fortified blank muscle and liver from different animal species according to the 2002/657/EC European decision criteria. The decision limits (CCalpha) and detection capabilities (CCbeta) were determined and their values were at concentrations near the MRL for each substance.

  15. Determination of water-soluble vitamins in infant milk and dietary supplement using a liquid chromatography on-line coupled to a corona-charged aerosol detector.

    PubMed

    Márquez-Sillero, Isabel; Cárdenas, Soledad; Valcárcel, Miguel

    2013-10-25

    A simple and rapid method for the simultaneous determination of seven water-soluble vitamins (thiamine, folic acid, nicotinic acid, ascorbic acid, pantothenic acid, pyridoxine and biotin) was developed by high performance liquid chromatographic separation and corona-charged aerosol detection. The water-soluble vitamins were separated on a Lichrosorb RP-C18 column under isocratic conditions with a mobile phase consisting of 0.05 M ammonium acetate:methanol 90:10 (v/v) at the flow rate 0.5 mL min(-1). The vitamins were extracted from the infant milk (liquid and powder format) using a precipitation step with 2.5 M acetic acid remaining the analyte in the supernatant. As far as dietary supplements are concerned, only a dilution with distilled water was required. The detection limits ranged from 0.17 to 0.62 mg L(-1) for dietary supplements and 1.7 to 6.5 mg L(-1) for milk samples. The precision of the method was evaluated in terms of relative standard deviation (%, RSD) under repeatability and reproducibility conditions, being the average values for each parameter 2.6 and 2.7 for dietary supplements and 4.3 and 4.6 for milk samples. The optimized method was applied to different infant milk samples and dietary supplements. The results of the analysis were in good agreement with the declared values.

  16. Cucurbit[6]uril: A Possible Host for Noble Gas Atoms.

    PubMed

    Pan, Sudip; Mandal, Subhajit; Chattaraj, Pratim K

    2015-08-27

    Density functional and ab initio molecular dynamics studies are carried out to investigate the stability of noble gas encapsulated cucurbit[6]uril (CB[6]) systems. Interaction energy, dissociation energy and dissociation enthalpy are calculated to understand the efficacy of CB[6] in encapsulating noble gas atoms. CB[6] could encapsulate up to three Ne atoms having dissociation energy (zero-point energy corrected) in the range of 3.4-4.1 kcal/mol, whereas due to larger size, only one Ar or Kr atom encapsulated analogues would be viable. The dissociation energy value for the second Ar atom is only 1.0 kcal/mol. On the other hand, the same for the second Kr is -0.5 kcal/mol, implying the instability of the system. The noble gas dissociation processes are endothermic in nature, which increases gradually along Ne to Kr. Kr encapsulated analogue is found to be viable at room temperature. However, low temperature is needed for Ne and Ar encapsulated analogues. The temperature-pressure phase diagram highlights the region in which association and dissociation processes of Kr@CB[6] would be favorable. At ambient temperature and pressure, CB[6] may be used as an effective noble gas carrier. Wiberg bond indices, noncovalent interaction indices, electron density, and energy decomposition analyses are used to explore the nature of interaction between noble gas atoms and CB[6]. Dispersion interaction is found to be the most important term in the attraction energy. Ne and Ar atoms in one Ng entrapped analogue are found to stay inside the cavity of CB[6] throughout the simulation at 298 K. However, during simulation Ng2 units in Ng2@CB[6] flip toward the open faces of CB[6]. After 1 ps, one Ne atom of Ne3@CB[6] almost reaches the open face keeping other two Ne atoms inside. At lower temperature (77 K), all the Ng atoms in Ngn@CB[6] remain well inside the cavity of CB[6] throughout the simulation time (1 ps).

  17. Noble Gas Signatures in Athabasca Glacier - Tracing Glacial Meltwater Sources

    NASA Astrophysics Data System (ADS)

    Niu, Y.; Hall, C. M.; Castro, M. C.; Aciego, S.; Arendt, C. A.

    2015-12-01

    We present a noble gas study in glacial meltwater (GMW) from the Athabasca Glacier (AG) in the Columbia Icefield, Canada. It constrains the relative contributions of GMW sources, water residence times, and spatial locations where the GMW originates in the alpine glacier. This is possible due to the conservative nature of noble gases and temperature dependency of their concentrations in water in equilibrium with the atmosphere (ASW) which allows for estimation of the altitude at which GMW originated. In addition, crustal He accumulates in water over time, allowing for estimation of water residence times. Water samples were collected in the morning on selected dates in May and July 2011 at two locations about 200 m apart near the terminus area at altitudes between 2000 m and 2100 m. Eight samples were collected in six different days. Results show that the major source of subglacial meltwater is ASW rather than old, compressed glacial ice, which has a distinct noble gas signature not seen in our samples. Given that, GMW samples from the AG do deviate to a certain extent from the ASW values corresponding to measured water temperature and altitude at collection points. Two patterns are observed in the concentrations of the AG samples. The first one presents a relative Ar enrichment with respect to Ne, Kr, and Xe, first observed in high-altitude springs in the Galápagos Islands (Warrier et al., 2012). The second one displays a mass-dependent pattern, first observed in Michigan rainwater (Warrier et al., 2013). A preliminary Xe analysis indicates equilibration altitudes between 2500 m and 3400 m, values compatible with local topography. Samples present He excess of 4% to 91%, and suggest an average residence time of ~400 yrs. References:Warrier, R. B., Castro, M. C., and Hall, C. M. (2012), Recharge and source-water insights from the Galapagos Islands using noble gases and stable isotopes, Water Resour. Res., 48, W03508, doi:10.1029/2011WR010954. Warrier, R. B., Castro

  18. Surface purity control during XMASS detector refurbishment

    SciTech Connect

    Kobayashi, Kazuyoshi

    2015-08-17

    The XMASS project aims at detecting dark matter, pp and {sup 7}Be solar neutrinos, and neutrino less double beta decay using large volume of pure liquid xenon. The first physics target of the XMASS project is to detect dark matter with 835 kg liquid xenon. After the commissioning runs, XMASS detector was refurbished to minimize the background contribution mainly from PMT sealing material and we restarted data taking in November 2013. We report how we control surface purity, especially how we prevent radon daughter accumulation on the detector copper surface, during XMASS detector refurbishment. The result and future plan of XMASS are also reported.

  19. Electrochemical Synthesis of Nanostructured Noble Metal Films for Biosensing

    NASA Astrophysics Data System (ADS)

    Bhattarai, Jay K.

    Nanostructures of noble metals (gold and silver) are of interest because of their important intrinsic properties. Noble metals by themselves are physically robust, chemically inert, highly conductive, and possess the capability to form strong bonds with thiols or dithiol molecules present in organic compounds, creating self-assembled monolayers with tunable functional groups at exposed interfaces. However, when the nanostructures are formed, they in addition possess high surface area and unique optical properties which can be tuned by adjusting the shape and the size of the nanostructures. All of these properties make nanostructures of noble metals suitable candidates to be used as a transducer for optical and electrochemical biosensing. Individual nanostructures might be easier to prepare but difficult to handle to use as a transducer. Therefore, we prepared and analyzed nanostructured films/coating of noble metals and used them as a transducer for optical and electrochemical biosensing. We have electrochemically prepared nanoporous gold (NPG) on gold wire varying different dependable parameters (deposition potential, time, and compositional ratio) to obtain an optimal structure in term of stability, morphology, and better surface area. NPG prepared using a deposition potential of --1.0 V for 10 min from 30:70% 50 mM potassium dicyanoaurate(I) and 50 mM potassium dicyanoargentate(I) was used as an optimal surface for protein immobilization, and to perform square wave voltammetry (SWV) based enzyme-linked lectinsorbent assays. On flat gold surfaces, adjacent protein molecules sterically block their active sites due to high-density packing, which can be minimized using NPG as a substrate. NPG can also show significant peak current in SWV experiments, a sensitive electrochemical technique that minimizes non-Faradaic current, which is difficult to obtain using a flat gold surface. These all make NPG a suitable substrate, electrode, and transducer to be used in

  20. Helium Solubility in Cyclosilicates and Implications for Noble Gas Recycling

    NASA Astrophysics Data System (ADS)

    Jackson, C.; Kelley, S. P.; Cooper, R. F.; Parman, S. W.

    2011-12-01

    It is commonly assumed that noble gases strictly flux from the mantle to the atmosphere, with negligible recycling, because noble gases are thought to be extremely insoluble in all minerals. To test this hypothesis, we have experimentally determined the He solubility in a suite of cyclosilicate minerals: beryl, tourmaline and cordierite. The experiments were run in a gas pressure vessel. Run products were analyzed by UV laser ablation, noble gas mass spectrometry. He has a remarkably high solubility (>1000 ppm/1.8 kbar PHe) in cyclosilicates with nominally vacant six-member Si-Al-tetrahedra rings. Cyclosilicates with nominally occupied ring sites have substantially lower solubility. This suggests that He dissolution is facilitated by unfilled six-member rings. If true, He should have a high solubility in other minerals that include ring sites, such as phyllosilicates and amphiboles. Subduction zones commonly recycle these minerals, providing a possible mechanism for recycling of noble gases back into the mantle. Gem quality, natural, polished crystals of each mineral were placed into graphite capsules. Pure He gas was used as the pressure medium (1800 bar), allowing for precise control of PHe. Temperatures were held at 750 C and the experimental durations were 8 hours. A capsule of hydrated MgO powder was loaded in the TZM to maintain a non-zero fugacity of water during the experiment. Close visual inspection of the run products gave no indication of breakdown products. Depth profiles (10s of microns) of the mineral faces were completed using a 193 nm excimer laser. Multiple measurements were made on each phase. He concentrations were homogenous, both vertically and horizontally, indicating a close approach to equilibrium and absence of inclusions. Compared to tourmaline, we observe that He is >1000 and >100 times more soluble in cordierite and beryl, respectively. The ring sites, also known as A sites, in beryl and cordierite are nominally vacant, where as the

  1. Fluid clathrate system for continuous removal of heavy noble gases from mixtures of lighter gases

    DOEpatents

    Gross, Kenneth C.; Markun, Francis; Zawadzki, Mary T.

    1998-01-01

    An apparatus and method for separation of heavy noble gas in a gas volume. An apparatus and method have been devised which includes a reservoir containing an oil exhibiting a clathrate effect for heavy noble gases with a reservoir input port and the reservoir is designed to enable the input gas volume to bubble through the oil with the heavy noble gas being absorbed by the oil exhibiting a clathrate effect. The gas having reduced amounts of heavy noble gas is output from the oil reservoir, and the oil having absorbed heavy noble gas can be treated by mechanical agitation and/or heating to desorb the heavy noble gas for analysis and/or containment and allow recycling of the oil to the reservoir.

  2. Fluid clathrate system for continuous removal of heavy noble gases from mixtures of lighter gases

    DOEpatents

    Gross, K.C.; Markun, F.; Zawadzki, M.T.

    1998-04-28

    An apparatus and method are disclosed for separation of heavy noble gas in a gas volume. An apparatus and method have been devised which includes a reservoir containing an oil exhibiting a clathrate effect for heavy noble gases with a reservoir input port and the reservoir is designed to enable the input gas volume to bubble through the oil with the heavy noble gas being absorbed by the oil exhibiting a clathrate effect. The gas having reduced amounts of heavy noble gas is output from the oil reservoir, and the oil having absorbed heavy noble gas can be treated by mechanical agitation and/or heating to desorb the heavy noble gas for analysis and/or containment and allow recycling of the oil to the reservoir. 6 figs.

  3. Detectors for the superconducting super collider, design concepts, and simulation

    SciTech Connect

    Gabriel, T.A.

    1989-06-01

    The physics of compensation calorimetry is reviewed in the light of the needs of the Superconducting Super Collider (SSC) detectors. The four major detector types: liquid argon, scintillator, room temperature liquids, and silicon, are analyzed with respect to some of their strengths and weaknesses. Finally, general comments are presented which reflect the reliability of simulation code systems.

  4. Analytical equation of state with three-body forces: Application to noble gases

    SciTech Connect

    Río, Fernando del Díaz-Herrera, Enrique; Guzmán, Orlando; Moreno-Razo, José Antonio; Ramos, J. Eloy

    2013-11-14

    We developed an explicit equation of state (EOS) for small non polar molecules by means of an effective two-body potential. The average effect of three-body forces was incorporated as a perturbation, which results in rescaled values for the parameters of the two-body potential. These values replace the original ones in the EOS corresponding to the two-body interaction. We applied this procedure to the heavier noble gases and used a modified Kihara function with an effective Axilrod-Teller-Muto (ATM) term to represent the two- and three-body forces. We also performed molecular dynamics simulations with two- and three-body forces. There was good agreement between predicted, simulated, and experimental thermodynamic properties of neon, argon, krypton, and xenon, up to twice the critical density and up to five times the critical temperature. In order to achieve 1% accuracy of the pressure at liquid densities, the EOS must incorporate the effect of ATM forces. The ATM factor in the rescaled two-body energy is most important at temperatures around and lower than the critical one. Nonetheless, the rescaling of two-body diameter cannot be neglected at liquid-like densities even at high temperature. This methodology can be extended straightforwardly to deal with other two- and three-body potentials. It could also be used for other nonpolar substances where a spherical two-body potential is still a reasonable coarse-grain approximation.

  5. Real-time, digital pulse-shape discrimination in non-hazardous fast liquid scintillation detectors: Prospects for safety and security

    SciTech Connect

    Joyce, M. J.; Aspinall, M. D.; Cave, F. D.; Lavietes, A. D.

    2011-07-01

    Pulse-shape discrimination (PSD) in fast, organic scintillation detectors is a long-established technique used to separate neutrons and {gamma} rays in mixed radiation fields. In the analogue domain the method can achieve separation in real time, but all knowledge of the pulses themselves is lost thereby preventing the possibility of any post- or repeated analysis. Also, it is typically reliant on electronic systems that are largely obsolete and which require significant experience to set up. In the digital domain, PSD is often more flexible but significant post-processing has usually been necessary to obtain neutron/{gamma}-ray separation. Moreover, the scintillation media on which the technique relies usually have a low flash point and are thus deemed hazardous. This complicates the ease with which they are used in industrial applications. In this paper, results obtained with a new portable digital pulse-shape discrimination instrument are described. This instrument provides real-time, digital neutron/{gamma} separation whilst preserving the synchronization with the time-of-arrival for each event, and realizing throughputs of 3 x 10{sup 6} events per second. Furthermore, this system has been tested with a scintillation medium that is non-flammable and not hazardous. (authors)

  6. Vertex detectors

    SciTech Connect

    Lueth, V.

    1992-07-01

    The purpose of a vertex detector is to measure position and angles of charged particle tracks to sufficient precision so as to be able to separate tracks originating from decay vertices from those produced at the interaction vertex. Such measurements are interesting because they permit the detection of weakly decaying particles with lifetimes down to 10{sup {minus}13} s, among them the {tau} lepton and charm and beauty hadrons. These two lectures are intended to introduce the reader to the different techniques for the detection of secondary vertices that have been developed over the past decades. The first lecture includes a brief introduction to the methods used to detect secondary vertices and to estimate particle lifetimes. It describes the traditional technologies, based on photographic recording in emulsions and on film of bubble chambers, and introduces fast electronic registration of signals derived from scintillating fibers, drift chambers and gaseous micro-strip chambers. The second lecture is devoted to solid state detectors. It begins with a brief introduction into semiconductor devices, and then describes the application of large arrays of strip and pixel diodes for charged particle tracking. These lectures can only serve as an introduction the topic of vertex detectors. Time and space do not allow for an in-depth coverage of many of the interesting aspects of vertex detector design and operation.

  7. A high-performance liquid chromatography with circular dichroism detector for determination of stereochemistry of 6, 9-oxygen bridge dibenzocyclooctadiene lignans from kadsura coccinea.

    PubMed

    Zhu, Hui; Xu, Liang; Yang, Shi-Lin; Li, He-Ran

    2015-10-01

    The stereochemistry of two 6, 9-oxygen bridge dibenzocyclooctadiene lignans from Kadsura coccinea, are difficult to separate and very unstable. The present study was designed to develop a high-performance liquid chromatography using circular dichroism detection for the analysis of the stereochemistry. A new 6, 9-oxygen bridge dibenzocyclooctadiene lignans named Kadsulignan Q was firstly found with an S-biphenyl configuration. The other compound was identified as Kadsulignan L with an R- biphenyl configuration. In order to obtain kinetic data on their reversible interconversion, the stability was measured at different deuterated solvents such as deuterated methanol, deuterated chloroform and deuterated dimethylsulfoxide. The lignans were more unstable and converted more easily in deuterated methanol than in deuterated chloroform and deuterated dimethylsulfoxide.

  8. The LUX-Zeplin Dark Matter Detector

    NASA Astrophysics Data System (ADS)

    Mock, Jeremy; Lux-Zeplin (Lz) Collaboration

    2016-03-01

    The LUX-ZEPLIN (LZ) detector is a second generation dark matter experiment that will operate at the 4850 foot level of the Sanford Underground Research Experiment as a follow-up to the LUX detector, currently the world's most sensitive WIMP direct detection experiment. The LZ detector will contain 7 tonnes of active liquid xenon with a 5.6 tonne fiducial mass in the TPC. The TPC is surrounded by an active, instrumented, liquid-xenon ``skin'' region to veto gammas, then a layer of liquid scintillator to veto neutrons, all contained within a water shield. Modeling the detector is key to understanding the expected background, which in turn leads to a better understanding of the projected sensitivity, currently expected to be 2e-48 cm2 for a 50 GeV WIMP. I will discuss the current status of the LZ experiment as well as its projected sensitivity.

  9. Quantitative Analysis and Comparison of Four Major Flavonol Glycosides in the Leaves of Toona sinensis (A. Juss.) Roemer (Chinese Toon) from Various Origins by High-Performance Liquid Chromatography-Diode Array Detector and Hierarchical Clustering Analysis

    PubMed Central

    Sun, Xiaoxiang; Zhang, Liting; Cao, Yaqi; Gu, Qinying; Yang, Huan; Tam, James P.

    2016-01-01

    Background: Toona sinensis (A. Juss.) Roemer is an endemic species of Toona genus native to Asian area. Its dried leaves are applied in the treatment of many diseases; however, few investigations have been reported for the quantitative analysis and comparison of major bioactive flavonol glycosides in the leaves harvested from various origins. Objective: To quantitatively analyze four major flavonol glycosides including rutinoside, quercetin-3-O-β-D-glucoside, quercetin-3-O-α-L-rhamnoside, and kaempferol-3-O-α-L-rhamnoside in the leaves from different production sites and classify them according to the content of these glycosides. Materials and Methods: A high-performance liquid chromatography-diode array detector (HPLC-DAD) method for their simultaneous determination was developed and validated for linearity, precision, accuracy, stability, and repeatability. Moreover, the method established was then employed to explore the difference in the content of these four glycosides in raw materials. Finally, a hierarchical clustering analysis was performed to classify 11 voucher specimens. Results: The separation was performed on a Waters XBridge Shield RP18 column (150 mm × 4.6 mm, 3.5 μm) kept at 35°C, and acetonitrile and H2O containing 0.30% trifluoroacetic acid as mobile phase was driven at 1.0 mL/min during the analysis. Ten microliters of solution were injected and 254 nm was selected to monitor the separation. A strong linear relationship between the peak area and concentration of four analytes was observed. And, the method was also validated to be repeatable, stable, precise, and accurate. Conclusion: An efficient and reliable HPLC-DAD method was established and applied in the assays for the samples from 11 origins successfully. Moreover, the content of those flavonol glycosides varied much among different batches, and the flavonoids could be considered as biomarkers to control the quality of Chinese Toon. SUMMARY Four major flavonol glycosides in the leaves

  10. Astroparticle Physics: Detectors for Cosmic Rays

    NASA Astrophysics Data System (ADS)

    Salazar, Humberto; Villaseñor, Luis

    2006-09-01

    We describe the work that we have done over the last decade to design and construct instruments to measure properties of cosmic rays in Mexico. We describe the measurement of the muon lifetime and the ratio of positive to negative muons in the natural background of cosmic ray muons at 2000 m.a.s.l. Next we describe the detection of decaying and crossing muons in a water Cherenkov detector as well as a technique to separate isolated particles. We also describe the detection of isolated muons and electrons in a liquid scintillator detector and their separation. Next we describe the detection of extensive air showers (EAS) with a hybrid detector array consisting of water Cherenkov and liquid scintillator detectors, located at the campus of the University of Puebla. Finally we describe work in progress to detect EAS at 4600 m.a.s.l. with a water Cherenkov detector array and a fluorescence telescope at the Sierra Negra mountain.

  11. Noble Metals and Spinel Settling in High Level Waste Glass Melters

    SciTech Connect

    Sundaram, S. K.; Perez, Joseph M.

    2000-09-30

    In the continuing effort to support the Defense Waste Processing Facility (DWPF), the noble metals issue is addressed. There is an additional concern about the amount of noble metals expected to be present in the future batches that will be considered for vitrification in the DWPF. Several laboratory, as well as melter-scale, studies have been completed by various organizations (mainly PNNL, SRTC, and WVDP in the USA). This letter report statuses the noble metals issue and focuses at the settling of noble metals in melters.

  12. Effective Giromagnetic Ratios in Artifical Nuclear Magnetization Pumping of the Noble Gases Mix

    NASA Astrophysics Data System (ADS)

    Popov, E. N.; Barantsev, K. A.; Litvinov, A. N.

    2015-09-01

    Dynamic of the nuclear magnetization of the two noble gases mix was studied in this research. Nuclear magnetization pumped along the induction of external magnetic field. Vector of nuclear magnetization is given a tilt by the week rotational magnetic field, which makes NMR for noble gases. Interaction between the nuclear magnetic moments of the different noble gases adducted to shifts at the frequency of nuclear moments precession in external magnetic field. Effective gyromagnetic ratios of the nuclear of noble gases is defined and it different from the tabulated value. There is theoretical calculation of effective gyromagnetic ratios in this research.

  13. Inert anode containing base metal and noble metal useful for the electrolytic production of aluminum

    DOEpatents

    Ray, Siba P.; Liu, Xinghua

    2000-01-01

    An inert anode for production of metals such as aluminum is disclosed. The inert anode comprises a base metal selected from Cu and Ag, and at least one noble metal selected from Ag, Pd, Pt, Au, Rh, Ru, Ir and Os. The inert anode may optionally be formed of sintered particles having interior portions containing more base metal than noble metal and exterior portions containing more noble metal than base metal. In a preferred embodiment, the base metal comprises Cu, and the noble metal comprises Ag, Pd or a combination thereof.

  14. SUBCOOLING DETECTOR

    DOEpatents

    McCann, J.A.

    1963-12-17

    A system for detecting and measuring directly the subcooling margin in a liquid bulk coolant is described. A thermocouple sensor is electrically heated, and a small amount of nearly stagnant bulk coolant is heated to the boiling point by this heated thermocouple. The sequential measurement of the original ambient temperature, zeroing out this ambient temperature, and then measuring the boiling temperature of the coolant permits direct determination of the subcooling margin of the ambient liquid. (AEC)

  15. The EXO-200 detector, part I: detector design and construction

    NASA Astrophysics Data System (ADS)

    Auger, M.; Auty, D. J.; Barbeau, P. S.; Bartoszek, L.; Baussan, E.; Beauchamp, E.; Benitez-Medina, C.; Breidenbach, M.; Chauhan, D.; Cleveland, B.; Conley, R.; Cook, J.; Cook, S.; Coppens, A.; Craddock, W.; Daniels, T.; Davis, C. G.; Davis, J.; deVoe, R.; Dobi, A.; Dolinski, M. J.; Dunford, M.; Fairbank, W., Jr.; Farine, J.; Fierlinger, P.; Franco, D.; Giroux, G.; Gornea, R.; Graham, K.; Gratta, G.; Hagemann, C.; Hall, C.; Hall, K.; Hargrove, C.; Herrin, S.; Hodgson, J.; Hughes, M.; Karelin, A.; Kaufman, L. J.; Kirk, J.; Kuchenkov, A.; Kumar, K. S.; Leonard, D. S.; Leonard, F.; LePort, F.; Mackay, D.; MacLellan, R.; Marino, M.; Merkle, K.; Mong, B.; Montero Díez, M.; Müller, A. R.; Neilson, R.; Odian, A.; O'Sullivan, K.; Ouellet, C.; Piepke, A.; Pocar, A.; Prescott, C. Y.; Pushkin, K.; Rivas, A.; Rollin, E.; Rowson, P. C.; Sabourov, A.; Sinclair, D.; Skarpaas, K.; Slutsky, S.; Stekhanov, V.; Strickland, V.; Swift, M.; Tosi, D.; Twelker, K.; Vuilleumier, J.-L.; Vuilleumier, J.-M.; Walton, T.; Weber, M.; Wichoski, U.; Wodin, J.; Wright, J. D.; Yang, L.; Yen, Y.-R.

    2012-05-01

    EXO-200 is an experiment designed to search for double beta decay of 136Xe with a single-phase, liquid xenon detector. It uses an active mass of 110 kg of xenon enriched to 80.6% in the isotope 136 in an ultra-low background time projection chamber capable of simultaneous detection of ionization and scintillation. This paper describes the EXO-200 detector with particular attention to the most innovative aspects of the design that revolve around the reduction of backgrounds, the efficient use of the expensive isotopically enriched xenon, and the optimization of the energy resolution in a relatively large volume.

  16. Pressure effects on the X-ray intrinsic position resolution in noble gases and mixtures

    NASA Astrophysics Data System (ADS)

    Azevedo, C. D. R.; González-Díaz, D.; Correia, P. M. M.; Biagi, S.; Silva, A. L. M.; Carramate, L. F. N. D.; Veloso, J. F. C. A.

    2016-12-01

    A study of the effect of gas pressure in the position resolution of an interacting X or γ-ray photon in a gas medium is performed. The intrinsic position resolution for pure noble gases (Argon and Xenon) and their mixtures with CO2 and CH4 was calculated for several gas pressures (1-10 bar) and for photon energies between 1 and 60 keV, being possible to establish a linear relation between the intrinsic position resolution and the inverse of the gas pressure in the indicated energy range, as intuitively expected. We show how, at high pressures and low photoelectron energies, this intrinsic 1/P scaling is modified due to the diffusion of the primary ionization in the direction perpendicular to the electric field. In order to evaluate the quality of the method here described, a comparison between the available experimental data and microscopic simulations is presented in this work and discussed. In the majority of cases, a good agreement is observed. The conditions to achieve position resolutions down to 10 μm in a realistic detector are shown and discussed.

  17. Updated compilations of electron scattering from ground-state, noble gas atoms

    NASA Astrophysics Data System (ADS)

    Biagi, S. F.

    2011-10-01

    An updated analysis of the cross sections for electron scattering from ground state atoms for noble gases in the energy range from thermalto 10 MeV is outlined. The work was driven by the necessity tounderstand the Penning transfers and light emission in detectors of high energy particles and dark matter. The published experimental data for electron scattering up to 2010 have been used in the analysis. Recent, theoretically improved cross sections have been used in the important threshold region for both the singlet and triplet states. Experimental or theoretical oscillator strengths and BEF scaling have been used above the resonance region for the singlet states. The number of excitation levels considered (typically about 40) is chosen so that the sum of the oscillator strengths for the considered levels is within a few percent of the theoretical sum rule. The resulting total cross sections are within a few percent of the measured values, and the calculated Fano factors are consistent with available data. These data are now available on the LXCat website. This work is part of the RD51 collaboration at CERN.

  18. Preliminary test results of LAr prototype detector

    NASA Astrophysics Data System (ADS)

    Li, Pei-Xian; Guan, Meng-Yun; Yang, Chang-Gen; Zhang, Peng; Liu, Jin-Chang; Zhang, Yong-Peng; Guo, Cong; Wang, Yi

    2016-11-01

    Liquid argon (LAr) is an attractive target for the direct detection of WIMPs. A LAr prototype detector was designed to study the technology and properties of LAr detectors. The prototype detector had an active volume containing 0.65 kg of liquid argon. A liquid nitrogen (LN) cooling system allowed the temperature fluctuation of the liquid argon to be controlled within less than 0.1 K during a one month run. In the 22Na calibration run, the LAr prototype obtained 1.59±0.02 p.e./keV light yield for 511 keV gamma rays using a domestic-made argon purification system. Supported by China Ministry of Science and Technology (2010CB833003), National Nature Science Foundation of China, Youth Science Found (11305188)

  19. Measuring the Noble Metal and Iodine Composition of Extracted Noble Metal Phase from Spent Nuclear Fuel Using Instrumental Neutron Activation Analysis

    SciTech Connect

    Palomares, R. I.; Dayman, Kenneth J.; Landsberger, Sheldon; Biegalski, Steven R.; Soderquist, Chuck Z.; Casella, Amanda J.; Brady Raap, Michaele C.; Schwantes, Jon M.

    2015-04-01

    Mass quantities of noble metal and iodine nuclides in the metallic noble metal phase extracted from spent fuel are measured using instrumental neutron activation analysis (NAA). Nuclide presence is predicted using fission yield analysis, and mass quantification is derived from standard gamma spectroscopy and radionuclide decay analysis. The nuclide compositions of noble metal phase derived from two dissolution methods, UO2 fuel dissolved in nitric acid and UO2 fuel dissolved in ammonium-carbonate and hydrogen-peroxide solution, are compared. Lastly, the implications of the rapid analytic speed of instrumental NAA are discussed in relation to potential nuclear forensics applications.

  20. Identification of protein binders in works of art by high-performance liquid chromatography-diode array detector analysis of their tryptic digests.

    PubMed

    Fremout, Wim; Sanyova, Jana; Saverwyns, Steven; Vandenabeele, Peter; Moens, Luc

    2009-04-01

    Proteins in works of art are generally determined by the relative amounts of amino acids. This method, however, implies a loss of information on the protein structure and its modifications. Consequently, we propose a method based on the analysis of trypsin digests using high-performance liquid chromatography (HPLC) UV diode array detection (DAD) for painting binder studies. All reaction steps are done in the same vial; no extraction methods or sample transfer is needed, reducing the risk of sample losses. A collection of pure binders (collagen, ovalbumin, yolk and casein) as well as homemade and historical paint samples have been investigated with this method. Chromatograms of unknowns at 214 nm and 280 nm are compared with those of the reference samples as a fingerprint. There is a good agreement between many peptides, but others seem to have been lost or their retention time shifted due to small compositional changes because of ageing and degradation of the paint. The results are comparable with the results of other techniques used for binder identification on the same samples, with the additional advantage of differentiation between egg yolk and glair.

  1. Determination of sulfadiazine in Jiaozhou Bay using molecularly imprinted solid-phase extraction followed by high-performance liquid chromatography with a diode-array detector.

    PubMed

    Lian, Ziru; He, Xingliang; Wang, Jiangtao

    2014-04-15

    A highly selective sample cleanup procedure featuring molecularly imprinted solid-phase extraction (MISPE) was developed for the isolation and determination of sulfadiazine (SDZ) in seawater samples from Jiaozhou Bay, China. The molecularly imprinted polymer (MIP) was prepared using SDZ as the template molecule and methacrylic acid as the functional monomer. The MIP was used as a selective sorbent for the solid-phase extraction of SDZ. An off-line MISPE method followed by high-performance liquid chromatography (HPLC) with diode-array detection was established for the analysis of SDZ. Good linearity of the MISPE column for SDZ standard solutions was obtained within 0-200μgL(-1) (R(2)>0.99). The recoveries of spiked seawater samples were satisfactory as high as 88%. Finally, seven samples in Jiaozhou Bay were determined and there was no sulfadiazine found except #2 and #5 sample. The concentrations were respectively 0.33μgL(-1) and 0.28μgL(-1), and the relative standard deviations were 1.35% and 4.13% (n=3).

  2. Noble gas isotopic composition as a key reference parameter in a planetary atmospheric evolution model

    NASA Astrophysics Data System (ADS)

    Ozima, M.

    2010-12-01

    The isotopic composition of noble gases is a key reference parameter in discussing the evolution of planetary atmospheres. Currently, two widely occurring noble gas components are identified in the early solar system, one is the Solar Wind noble gas (SW-noble gas, hereafter) and another is the Q-noble gas in unaltered meteorites: both noble gases are characterized by their ubiquitous occurrence and high isotopic homogeneity. Since the SW-noble gas is directly ejected from the Sun, it has been assumed to be a good proxy of the average noble gas isotopic composition in the Sun, namely the solar noble gas. The systematic enrichment of the heavier isotopes in the Q-noble gas relative to the SW-noble gas is then commonly attributed to its isotopic fractionation from the SW-noble gas. However, the isotopic compositions of the SW-noble gas either implanted on lunar soils or trapped by artificial targets show considerable isotopic variation depending on the velocity of the Solar Wind. Therefore, it is important to examine how closely the SW-noble gas represents the indigenous solar noble gas component or the mean isotopic composition of noble gases of the Sun. Here we show that the isotopic composition of the SW-noble gas is substantially fractionated relative to the solar value, and therefore should not be used as a reference parameter. We further suggest that the post D-burning Q-noble gas (see below) is the better proxy of the solar noble gas, and this should be used as a reference of the Solar noble gas isotopic composition in discussing the planetary atmospheric evolution. The most distinct difference between the Q- and the SW-noble gas is apparent in a 3He/4He isotopic ratio: 4.64e-4 in Q-He [1], but 1.23e-4 in SW-He[2]. The difference is attributed to the conversion of deuteron (D) to 3He in the Sun, namely the D-burning [3], due to high temperature during the pre-main sequence stage of the Sun. With the use of recent data on D/H ratios from helio-seismology [4] and

  3. Flame Detector

    NASA Technical Reports Server (NTRS)

    1990-01-01

    Scientific Instruments, Inc. has now developed a second generation, commercially available instrument to detect flames in hazardous environments, typically refineries, chemical plants and offshore drilling platforms. The Model 74000 detector incorporates a sensing circuit that detects UV radiation in a 100 degree conical field of view extending as far as 250 feet from the instrument. It operates in a bandwidth that makes it virtually 'blind' to solar radiation while affording extremely high sensitivity to ultraviolet flame detection. A 'windowing' technique accurately discriminates between background UV radiation and ultraviolet emitted from an actual flame, hence the user is assured of no false alarms. Model 7410CP is a combination controller and annunciator panel designed to monitor and control as many as 24 flame detectors. *Model 74000 is no longer being manufactured.

  4. Neutron detector

    DOEpatents

    Stephan, Andrew C.; Jardret; Vincent D.

    2011-04-05

    A neutron detector has a volume of neutron moderating material and a plurality of individual neutron sensing elements dispersed at selected locations throughout the moderator, and particularly arranged so that some of the detecting elements are closer to the surface of the moderator assembly and others are more deeply embedded. The arrangement captures some thermalized neutrons that might otherwise be scattered away from a single, centrally located detector element. Different geometrical arrangements may be used while preserving its fundamental characteristics. Different types of neutron sensing elements may be used, which may operate on any of a number of physical principles to perform the function of sensing a neutron, either by a capture or a scattering reaction, and converting that reaction to a detectable signal. High detection efficiency, an ability to acquire spectral information, and directional sensitivity may be obtained.

  5. Angle detector

    NASA Technical Reports Server (NTRS)

    Parra, G. T. (Inventor)

    1978-01-01

    An angle detector for determining a transducer's angular disposition to a capacitive pickup element is described. The transducer comprises a pendulum mounted inductive element moving past the capacitive pickup element. The capacitive pickup element divides the inductive element into two parts L sub 1 and L sub 2 which form the arms of one side of an a-c bridge. Two networks R sub 1 and R sub 2 having a plurality of binary weighted resistors and an equal number of digitally controlled switches for removing resistors from the networks form the arms of the other side of the a-c bridge. A binary counter, controlled by a phase detector, balances the bridge by adjusting the resistance of R sub 1 and R sub 2. The binary output of the counter is representative of the angle.

  6. Noble metal nanoparticles: Optical forces, electrochemical Ostwald ripening, and photovoltage

    NASA Astrophysics Data System (ADS)

    Redmond, Peter

    This thesis describes three distinct aspects of the chemical properties of noble metal nanoparticles. The first chapter introduces the surface plasmon resonance of noble metal nanoparticles. The second chapter presents an electrodynamic model for the calculation of the attractive optical forces that arise when two dielectric particles are irradiated in a light field. These forces show resonances at dipolar plasmon wavelengths, similar to resonances in the near-field electromagnetic intensities. At MW/cm2 intensities, optical forces can be stronger than van der Waals forces. The third chapter investigates the size dependent electrochemical properties of silver nanoparticles. These thermally evaporated silver nanoparticles spontaneously evolve in size when immersed in pure water on conducting substrates. The process is understood through an electrochemical Ostwald ripening mechanism driven by the size dependence of the work function and standard electrode potential. The fourth and fifth chapters consider photo-induced surface reactivity of noble metal particles. First, in the fourth chapter, the light driven deposition of copper onto gold nanoparticle electrodes is presented. The photocurrent is a nonlinear function of laser intensity and increases sharply with cathodic voltage in the underpotential deposition region. The photoreduction is attributed to laser heating (caused by decay of the plasmon oscillation) of the Au nanoparticles, rather than "hot electron" processes. Secondly, in the fifth chapter, the photo-induced oxidation of citrate is studied on silver nanoparticle electrodes. Irradiation of the citrate coated particles is shown to cause the particles to charge negatively from the irreversible transfer of electrons from citrate to the particles. It is hypothesized that the particle plasmon oscillation decays into electron hole pair(s) that causes the photo-oxidation of the surface bound citrate. Both the gold and silver particle systems are simulated using

  7. Catalytic reforming using group VIII noble metal high silica faujasites

    SciTech Connect

    Vaughan, D.E.; Ghosh, A.K

    1989-05-23

    A process is described for reforming a naphtha feed stock utilizing a catalytic faujasite zeolite composition, which comprises contacting the feed stock at reforming conditions and in the presence of hydrogen with the catalytic zeolite having a faujasite structure and having a SiO/sub 2//Al/sub 2/O/sub 3/ ratio between about 10 and 80 and containing a Group VIII noble metal dispersed therein so as to have a dispersion of hydrogen to metal of about 0.1 to 1, as measured by hydrogen chemisorption.

  8. Distribution of solar wind implanted noble gases in lunar samples

    NASA Technical Reports Server (NTRS)

    Kiko, J.; Kirsten, T.

    1986-01-01

    The distribution of solar wind implanted noble gases in lunar samples depends on implantation energy, fluence, diffusion, radiation damage and erosion. It is known that at least the lighter rare gases are fractionated after implantation, but the redistribution processes, which mainly drive the losses, are not well understood. Some information about this one can get by looking at the concentration profiles of solar wind implanted He-4 measured by the Gas Ion Probe in single lunar grains. The observed profiles were divided in three groups. These groups are illustrated and briefly discussed.

  9. Effect of Noble Gases on Sonoluminescence Temperatures during Multibubble Cavitation

    SciTech Connect

    Didenko, Yuri T.; McNamara, William B. III; Suslick, Kenneth S.

    2000-01-24

    Sonoluminescence spectra were collected from Cr(CO){sub 6} solutions in octanol and dodecane saturated with various noble gases. The emission from excited-state metal atoms serves as an internal thermometer of cavitation. The intensity and temperature of sonoluminescence increases from He to Xe. The intensity of the underlying continuum, however, grows faster with increasing temperature than the line emission. Dissociation of solvent molecules within the bubble consumes a significant fraction of the energy generated by the collapsing bubble, which can limit the final temperature inside the bubble. (c) 2000 The American Physical Society.

  10. The Noble Gas Fingerprint in a UK Unconventional Gas Reservoir

    NASA Astrophysics Data System (ADS)

    McKavney, Rory; Gilfillan, Stuart; Györe, Domokos; Stuart, Fin

    2016-04-01

    In the last decade, there has been an unprecedented expansion in the development of unconventional hydrocarbon resources. Concerns have arisen about the effect of this new industry on groundwater quality, particularly focussing on hydraulic fracturing, the technique used to increase the permeability of the targeted tight shale formations. Methane contamination of groundwater has been documented in areas of gas production1 but conclusively linking this to fugitive emissions from unconventional hydrocarbon production has been controversial2. A lack of baseline measurements taken before drilling, and the equivocal interpretation of geochemical data hamper the determination of possible contamination. Common techniques for "fingerprinting" gas from discrete sources rely on gas composition and isotopic ratios of elements within hydrocarbons (e.g. δ13CCH4), but the original signatures can be masked by biological and gas transport processes. The noble gases (He, Ne, Ar, Kr, Xe) are inert and controlled only by their physical properties. They exist in trace quantities in natural gases and are sourced from 3 isotopically distinct environments (atmosphere, crust and mantle)3. They are decoupled from the biosphere, and provide a separate toolbox to investigate the numerous sources and migration pathways of natural gases, and have found recent utility in the CCS4 and unconventional gas5 industries. Here we present a brief overview of noble gas data obtained from a new coal bed methane (CBM) field, Central Scotland. We show that the high concentration of helium is an ideal fingerprint for tracing fugitive gas migration to a shallow groundwater. The wells show variation in the noble gas signatures that can be attributed to differences in formation water pumping from the coal seams as the field has been explored for future commercial development. Dewatering the seams alters the gas/water ratio and the degree to which noble gases degas from the formation water. Additionally the

  11. Mechanical response of noble gas films to an oscillating substrate

    NASA Astrophysics Data System (ADS)

    Kobayashi, Hajime; Taniguchi, Junko; Suzuki, Masaru; Miura, Kouji; Arakawa, Ichiro

    2012-12-01

    We carried out quartz-crystal microbalance (QCM) experiments for Xe films adsorbed on an exfoliated single-crystalline graphite substrate (Xe/Gr) and Kr 1ms adsorbed on a synthetic mica substrate (Kr/mica) around LN2 temperature. For Xe/Gr, it was found that the resonance frequency decreases greatly around the first layer completion, while it does not decrease at low coverages. The observed behavior is similar to that of Kr films on a graphite substrate (Kr/Gr). This demonstrates that the layer completion strongly affects the sliding motion of noble gas films on graphite.

  12. Profiling of components of rhizoma et radix polygoni cuspidati by high-performance liquid chromatography with ultraviolet diode-array detector and ion trap/time-of-flight mass spectrometric detection

    PubMed Central

    Fu, Jinfeng; Wang, Min; Guo, Huimin; Tian, Yuan; Zhang, Zunjian; Song, Rui

    2015-01-01

    Introduction: Rhizoma et Radix Polygoni Cuspidati (Huzhang in Chinese, HZ) is a traditional medicinal plant in China. Many of the components of HZ have been proved to be bioactive while it is difficult to conduct a comprehensive chemical profiling of HZ as a consequence of the absence of efficient separation system and sensitive detective means. We developed a simple and effective method for comprehensive characterization of constituents in HZ. Objective: To develop a simple and effective method to characterize the components in HZ and provide useful information for subsequent metabolic studies of HZ. Materials and Methods: The components in HZ aqueous extract were characterized by using high performance liquid chromatography with UV diode-array detector (HPLC-DAD) and ion trap/time-of-flight mass spectrometric detection (HPLC-IT/TOF). Stilbenes, anthraquinones, gallates and tannins, naphthalenes and some other compounds were identified and confirmed by diagnostic fragment ions with accurate mass measurements, characteristic fragmentation pathways and relevant published literatures. Results: Among the 238 constituents detected in HZ, a total number of 74 constituents were identified unambiguously or tentatively, including 29 compounds reported for the first time in HZ. Conclusion: The identification and structure elucidation of these chemicals provided essential data for quality control and further in vivo metabolic studies of HZ. Key words: Polygonum cuspidatum, HPLC-DAD, HPLC-IT/TOF, qualitative analysis. PMID:26246723

  13. Characterization and identification of the chemical constituents from tartary buckwheat (Fagopyrum tataricum Gaertn) by high performance liquid chromatography/photodiode array detector/linear ion trap FTICR hybrid mass spectrometry.

    PubMed

    Ren, Qiang; Wu, Caisheng; Ren, Yan; Zhang, Jinlan

    2013-02-15

    In recent years tartary buckwheat has become popular healthful food due to its antioxidant, antidiabetic and antitumor activities. However, its chemical constituents have not yet been fully characterized and identified. In this paper, a novel high performance liquid chromatography coupled with photodiode array detector and linear ion trap FTICR hybrid mass spectrometry (HPLC-PDA/LTQ-FTICRMS) method was established to characterize and identify a total of 36 compounds by a single run. The retention time, maximum UV absorption wavelength, accurate mass weight and characteristic fragment ions were collected on line. To confirm the structures, 11 compounds were isolated and identified by MS and NMR experiments. 1, 3, 6, 6'-tetra-feruloyl sucrose named taroside was a new phenlypropanoid glycoside, together with 3, 6-di-p-coumaroyl-1, 6'-di-feruloyl sucrose, 1, 6, 6'-tri-feruloyl-3-p-coumaroyl sucrose, N-trans-feruloyltyramine and quercetin-3-O-[β-D-xyloxyl-(1→2)-α-L-rhamnoside] were isolated for the first time from the Fagopyrum species. The research enriched the chemical information of tartary buckwheat.

  14. High performance liquid chromatography with an electrochemical detector in the cathodic mode as a tool for the determination of p-nitrophenol and assay of acid phosphatase in urine samples.

    PubMed

    Yamauchi, Yuji; Ido, Megumi; Ohta, Merime; Maeda, Hatsuo

    2004-05-01

    Utilizing a commercially available helium-purging device and PEEK tubes for all tubing, especially for connection between the mobile phase and pump, high performance liquid chromatography with an electrochemical detector (ECD/HPLC) at the cathodic mode is a simple and precise method for the determination of p-nitrophenol (NP). Studies with cyclic and hydrodynamic voltammetry indicated that 25% aqueous MeOH containing 0.1% (v/v) CF(3)CO(2)H and -0.8 V vs. Ag/AgCl are the best mobile phase and detection potential for cathodic ECD/HPLC. With the present system, the limits of detection and determination were 0.2 and 0.25 microM, respectively, and up to 50 microM, a linear calibration curve was afforded. Within-day precisions for the analysis of 5 and 50 microM NP were 0.8 and 0.7% (n=6), respectively, and between-day precisions (n=6) for these samples were 3.5 and 2.2%, respectively. Compared with the commonly used Bessey-Lowry-Brock method, cathodic ECD/HPLC was useful for the assay of acid phosphatase in urine samples with p-nitrophenyl phosphate disodium salt as a substrate.

  15. Rapid Identification and Simultaneous Quantification of Multiple Constituents in Nao-Shuan-Tong Capsule by Ultra-Fast Liquid Chromatography/Diode-Array Detector/Quadrupole Time-of-Flight Tandem Mass Spectrometry.

    PubMed

    Li, Panlin; Su, Weiwei; Xie, Chengshi; Zeng, Xuan; Peng, Wei; Liu, Menghua

    2015-07-01

    A rapid and high-sensitive ultra-fast liquid chromatography coupled with a diode-array detector and a quadrupole/time-of-flight mass spectrometry (MS) method was established and validated for the chemical profiling of Nao-shuan-tong capsule (NSTC) and simultaneous quantification of five major constituents. A total of 59 components including monoterpene glycosides, flavonoids, sesquiterpenoids, ketosteroids, thiophenes, organic acids and alkaloids were identified or tentatively characterized in NSTC based on the accurate mass and tandem MS behavior. Five major bioactive constituents were chosen as the chemical indexes of holistic quality evaluation and quantified simultaneously. All calibration curves showed good linear regression (r(2) > 0.9991) in the range 25.2-510, 145-2,900, 1.84-36.8, 2.61-52.2 and 3.25-26.2 μg/mL for gastrodin, paeoniflorin, typhaneoside, β-ecdysterone and isorhamnetin-3-O-neohesperidoside, respectively. It also showed good precision, stability and accuracy for quantification of these five compounds. The limit of detections and limit of quantitations for the analytes ranged from 0.14 to 1.09 μg/mL and from 0.47 to 3.63 μg/mL, respectively. The validated quantification method was applied to analyze 10 batches of commercial NSTC. These results will provide a basis for quality control of the production process and the further pharmacological study in vivo of NSTC.

  16. Application of a validated method in the stability study of colistin sulfate and methylparaben in a veterinary suspension formulation by high-performance liquid chromatography with a diode array detector.

    PubMed

    Pérez-Lozano, Pilar; García-Montoya, Encarna; Orriols, Anna; Miñarro, Montse; Ticó, Josep Ramon; Suñé-Negre, Josep Maria

    2007-01-01

    A methodology following International Cooperation on Harmonization for Veterinary Products (VICH) guidelines for the stability evaluation of colistin sulfate in a nonaqueous suspension pharmaceutical dosage form for veterinary use (via their drinking water) is described. This method monitors the percentage of colistin sulfate during the stability study of the preparation in drinking water and establishes the shelf life of the final product by a new high-performance liquid chromatography method which was developed and validated for the simultaneous determination of colistin sulfate [colistin A (Polymixin E1) and colistin B (Polymixin E2)] and methylparaben (Nipagin) using a diode array detector (DAD). The method uses a Kromasil C18 column and isocratic elution. The mobile phase consisted of an acetonitrile-sodium sulfate anhydrous solution (25 + 75) pumped at a flow rate of 1.5 mL/min. The DAD was set at 215 nm. The validation study was carried out according to the VICH guidelines in order to prove that the new analytical method meets the reliability characteristics, which include the fundamental criteria for validation: selectivity, linearity, precision, accuracy, and sensitivity. The method was applied during the quality control or stability studies of the suspension dosage form in order to quantify the drug (colistin) and preservative, and proved to be suitable for rapid and reliable quality control.

  17. Analysis and improved characterization of minor antioxidants from leaves of Malus doumeri using a combination of major constituents' knockout with high-performance liquid chromatography-diode array detector-quadrupole time-of-flight tandem mass spectrometry.

    PubMed

    Zhao, Huading; Hu, Xin; Chen, Xiaoqin; Shi, Shuyun; Jiang, Xinyu; Liang, Xuejuan; Chen, Wei; Zhang, Shuihan

    2015-06-12

    Due to the complexity of natural products, efficient identification of bioactive compounds, especially for minor compounds, would require a huge effort. Here, we developed an effective strategy based on combining major constituents' knockout with high-performance liquid chromatography-diode array detector-quadrupole time-of-flight tandem mass spectrometry (HPLC-DAD-QTOF-MS/MS) to comprehensively identify minor antioxidants in Malus doumeri, one of the longest known and most used tonic plant in Taiwan. First, five major compounds (I-V) in M. doumeri were knocked out by two-step stepwise high-speed countercurrent chromatography (HSCCC). Second, minor antioxidants were screened by 1,1-diphenyl-2-picrylhydrazyl radical-HPLC (DPPH-HPLC) assay. Third, structures of thirty minor antioxidants, including 11 dihydrochalcones, 4 flavanones, 3 flavonols, 2 flavones, 3 aurones and 7 phenolic acids, were unambiguously or tentatively identified by matching their characteristic UV spectra, accurate mass signals and key diagnostic fragment ions with standards or previously reported compounds. Twenty-six of them, as far as was known, were discovered from M. doumeri for the first time. The results indicated that the proposed method was a useful approach to explore minor bioactive compounds from complex natural products.

  18. The phonon theory of liquid thermodynamics

    PubMed Central

    Bolmatov, D.; Brazhkin, V. V.; Trachenko, K.

    2012-01-01

    Heat capacity of matter is considered to be its most important property because it holds information about system's degrees of freedom as well as the regime in which the system operates, classical or quantum. Heat capacity is well understood in gases and solids but not in the third main state of matter, liquids, and is not discussed in physics textbooks as a result. The perceived difficulty is that interactions in a liquid are both strong and system-specific, implying that the energy strongly depends on the liquid type and that, therefore, liquid energy can not be calculated in general form. Here, we develop a phonon theory of liquids where this problem is avoided. The theory covers both classical and quantum regimes. We demonstrate good agreement of calculated and experimental heat capacity of 21 liquids, including noble, metallic, molecular and hydrogen-bonded network liquids in a wide range of temperature and pressure. PMID:22639729

  19. Simultaneous quantification of crocetin esters and picrocrocin changes in Chinese saffron by high-performance liquid chromatography-diode array detector during 15 years of storage

    PubMed Central

    Tong, Yingpeng; Yan, Yongqiu; Zhu, Xingyi; Liu, Ruoxi; Gong, Feng; Zhang, Ling; Wang, Ping

    2015-01-01

    Background: Saffron, which is made up of the dried stigmas of Crocus sativus L., has been successfully cultivated in China since 1970s and Zhejiang province is now the largest producing area in China, but the contents of crocetin esters and picrocrocin in saffron from Zhejiang province has not been determined simultaneously by high-performance liquid chromatography (HPLC) and changes of these constituents in Chinese saffron during storage for years has not been studied. Object: To establish a simple method quantification of the five main compounds including picrocrocin and four crocetin esters in saffron from main producing areas of China and study the influence of storage time on the changes of saffron constituents. Materials and Methods: A simple, sensitive, and accurate HPLC method was developed for simultaneous determination of five major active components in saffron and eight samples which collected from the same farm of Zhejiang province in different years were analyzed. Results: The correlation coefficient values (R2 > 0.9997) indicated good correlations between the investigated compounds’ concentrations and their peak areas within the test ranges. The limits of quantification and detection of the five compounds were 0.53–2.76 μg/mL and 0.11–0.77 μg/mL, respectively. The recoveries ranged from 94.67% to 101.31%, and the overall relative standard deviations for intra-day and inter-day were lower than 3.49%. The method was applied to study the changes of crocetin esters and picrocrocin contents in saffron samples during 15 years of storage. The losses of crocetin esters and picrocrocin in saffron with 1 -year storage were 52.2% and 54.3%, respectively. The trend then declined during subsequent storage. Conclusion: The developed method can be applied to the intrinsic quality control of saffron. PMID:26246729

  20. Quantification of nimesulide in human plasma by high-performance liquid chromatography with ultraviolet detector (HPLC-UV): application to pharmacokinetic studies in 28 healthy Korean subjects.

    PubMed

    Kim, Mi-Sun; Park, Yoo-Sin; Kim, Shin-Hee; Kim, Sang-Yeon; Lee, Min-Ho; Kim, Youn-Hee; Kim, Do-Wan; Yang, Seok-Chul; Kang, Ju-Seop

    2012-05-01

    Nimesulide is a selective COX-2 inhibitor that is as effective as the classical non-acidic nonsteroidal anti-inflammatory drugs in the relief of various pain and inflammatory conditions, but is better tolerated with lower incidences of adverse effects than other drugs. After oral dose of 100 mg nimesulide to western subjects, a mean maximal concentration (C(max)) of 2.86 ∼ 6.5 µg/mL was reached at 1.22 ∼ 2.75 h and mean t(1/2β) of 1.8 ∼ 4.74 h. This study developed a robust method for quantification of nimesulide for the pharmacokinetics and suitability of its dosage in Korea and compared its suitability with other racial populations. Nimesulide and internal standard were extracted from acidified samples with methyl tert-butyl ether and analyzed by high-performance liquid chromatography with ultraviolet detection (HPLC-UV). The 28 healthy volunteers took 2 tablets of 100 mg nimesulide and blood concentrations were analyzed during the 24 h post dose. Several pharmacokinetic parameters were represented: AUC(0-infinity) = 113.0 mg-h/mL, C(max) = 12.06 mg/mL, time for maximal concentrations (T(max)) = 3.19 h and t(1/2β) = 4.51 h. These were different from those of western populations as follows: AUC was 14.5% and C(max) was 28% that of of Korean subjects and T(max) and t(1/2β) were also different. The validated HPLC-UV method was successfully applied for the pharmacokinetic studies of nimesulide in Korean subjects. Because the pharmacokinetics of nimesulide were different from western populations, its dosage regimen needs to be adjusted for Koreans.

  1. Polydimethylsiloxane/metal-organic frameworks coated stir bar sorptive extraction coupled to high performance liquid chromatography-ultraviolet detector for the determination of estrogens in environmental water samples.

    PubMed

    Hu, Cong; He, Man; Chen, Beibei; Zhong, Cheng; Hu, Bin

    2013-10-04

    In this work, three kinds of metal-organic frameworks (MOFs), MOF-5, MOF-199 and IRMOF-3, were introduced in stir bar sorptive extraction (SBSE) and novel polydimethylsiloxane (PDMS)/MOFs (including PDMS/MOF-5, PDMS/MOF-199 and PDMS/IRMOF-3) coated stir bars were prepared by sol-gel technique. These PDMS/MOFs coatings were characterized and critically compared for the extraction of seven target estrogens (17-β-estradiol, dienestrol, diethylstilbestrol, estrone, 4-t-octylphenol, bisphenol-A and 17α-ethynylestradiol) by SBSE, and the results showed that PDMS/IRMOF-3 exhibited highest extraction efficiency. Based on the above facts, a novel method of PDMS/IRMOF-3 coating SBSE-high performance liquid chromatography ultraviolet (HPLC-UV) detection was developed for the determination of seven target estrogens in environmental waters. Several parameters affecting extraction of seven target estrogens by SBSE (PDMS/IRMOF-3) including extraction time, stirring rate, pH, ionic strength, desorption solvent and desorption time were investigated. Under the optimal experimental conditions, the limits of detection (LODs, S/N=3) were found to be in the range of 0.15-0.35 μg/L. The linear range was 2-2,500 μg/L for 17α-ethynylestradiol and 1-2,500 μg/L for other estrogens. The relative standard deviations (RSDs) were in the range of 3.7-9.9% (n=8, c=20 μg/L) and the enrichment factors were from 30.3 to 55.6-fold (theoretical enrichment factor was 100-fold). The proposed method was successfully applied to the analysis of estrogens in environmental water samples, and quantitative recoveries were obtained for the spiking experiments.

  2. Simultaneous quantification of amphetamines, caffeine and ketamine in urine by hollow fiber liquid phase microextraction combined with gas chromatography-flame ionization detector.

    PubMed

    Xiong, Jun; Chen, Jie; He, Man; Hu, Bin

    2010-08-15

    A method of hollow fiber (HF) liquid phase microextraction (LPME) combined with gas chromatography (GC)-flame ionization detection (FID) was developed for the simultaneous quantification of trace amphetamine (AP), methamphetamine (MA), methylenedioxyamphetamine (MDA), methylenedioxymethamphetamine (MDMA), caffeine and ketamine (KT) in drug abuser urine samples. The factors affecting on the extraction of six target analytes by HF-LPME were investigated and optimized, and the subsequent analytical performance evaluation and real sample analysis were performed by the extraction of six target analytes in sample solution containing 30% NaCl (pH 12.5) for 20 min with extraction temperature of 30 degrees C and stirring rate of 1000 rpm. Under such optimal conditions, the limits of detection (LODs, S/N=3) for the six target analytes were ranged from 8 microg/L (AP, KT) to 82 microg/L (MDA), with the enrichment factors (EFs) of 5-227 folds, and the relative standard deviations (RSDs, n=7) were in the range of 6.9-14.1%. The correlation coefficients of the calibration for the six target analytes over the dynamic linear range were higher than 0.9958. The application feasibility of HF-LPME-GC-FID in illegal drug monitoring was demonstrated by analyzing drug abuser urine samples, and the recoveries of target drugs for the spiked sample ranging from 75.2% to 119.3% indicated an excellent anti-interference capability of the developed method. The proposed method is simple, effective, sensitive and low-cost, and provides a much more accurate and sensitive detection platform over the conventional analytical techniques (such as immunological assay) for drug abuse analysis.

  3. A novel automated hydrophilic interaction liquid chromatography method using diode-array detector/electrospray ionization tandem mass spectrometry for analysis of sodium risedronate and related degradation products in pharmaceuticals.

    PubMed

    Bertolini, Tiziana; Vicentini, Lorenza; Boschetti, Silvia; Andreatta, Paolo; Gatti, Rita

    2014-10-24

    A simple, sensitive and fast hydrophilic interaction liquid chromatography (HILIC) method using ultraviolet diode-array detector (UV-DAD)/electrospray ionization tandem mass spectrometry was developed for the automated high performance liquid chromatography (HPLC) determination of sodium risedronate (SR) and its degradation products in new pharmaceuticals. The chromatographic separations were performed on Ascentis Express HILIC 2.7μm (150mm×2.1mm, i.d.) stainless steel column (fused core). The mobile phase consisted of formate buffer solution (pH 3.4; 0.03M)/acetonitrile 42:58 and 45:55 (v/v) for granules for oral solution and effervescent tablet analysis, respectively, at a flow-rate of 0.2mL/min, setting the wavelength at 262nm. Stability characteristics of SR were evaluated by performing stress test studies. The main degradation product formed under oxidation conditions corresponding to sodium hydrogen (1-hydroxy-2-(1-oxidopyridin-3-yl)-1-phosphonoethyl)phosphonate was characterized by high performance liquid chromatography-electrospray ionization-mass tandem mass spectrometry (HPLC-ESI-MS/MS). The validation parameters such as linearity, sensitivity, accuracy, precision and selectivity were found to be highly satisfactory. Linear responses were observed in standard and in fortified placebo solutions. Intra-day precision (relative standard deviation, RSD) was ≤1.1% for peak area and ≤0.2% for retention times (tR) without significant differences between intra- and inter-day data. Recovery studies showed good results for all the examined compounds (from 98.7 to 101.0%) with RSD ranging from 0.6 to 0.7%. The limits of detection (LOD) and quantitation (LOQ) were 1 and 3ng/mL, respectively. The high stability of standard and sample solutions at room temperature means an undoubted advantage of the method allowing the simultaneous preparation of many samples and consecutive chromatographic analyses by using an autosampler. The developed stability indicating

  4. Effect of noble metal adhesive systems on bonding between an indirect composite material and a gold alloy.

    PubMed

    Nagano, Kiyoshi; Tanoue, Naomi; Atsuta, Mitsuru; Koizumi, Hiroyasu; Matsumura, Hideo

    2004-12-01

    In this study, the bond strength between an indirect composite and a gold alloy was determined for the purpose of evaluating noble metal bonding systems. A single liquid primer designed for conditioning noble metal alloys (Infis Opaque Primer) and tri-n-butylborane-initiated adhesive resins (Super-Bond C & B), with or without the powder component, were assessed. Cast gold alloy disks (Casting Gold type IV) were air-abraded with alumina, followed by six surface preparations, and were then bonded with a light-activated composite material (New Metacolor Infis). Shear testing was performed both before and after thermocycling for evaluation of bond durability. The results showed that three primed groups improved post-thermocycling bond strengths compared to each of the corresponding unprimed groups (P < 0.01). The bond strength was reduced for all six groups by the application of thermocycling (P < 0.01). After thermocycling, the group primed with the Infis Opaque Primer material and bonded with the Super-Bond C & B resin exhibited the greatest bond strength (23.4 MPa). The Infis Opaque Primer and Super-Bond bonding system increased the post-thermocycling bond strength of the control group by a factor of approximately ten. This simple technique is applicable in the fabrication of composite veneered restorations and cone-telescope dentures.

  5. Composition of structural carbohydrates in biomass: precision of a liquid chromatography method using a neutral detergent extraction and a charged aerosol detector.

    PubMed

    Godin, Bruno; Agneessens, Richard; Gerin, Patrick A; Delcarte, Jérôme

    2011-09-30

    We adapted and optimized a method to quantify the cellulose, hemicellulose, xylan, arabinan, mannan, galactan contents in lignocellulosic biomass. This method is based on a neutral detergent extraction (NDE) of the interfering biomass components, followed by a sulfuric acid hydrolysis (SAH) of the structural polysaccharides, and a liquid chromatography with charged aerosol detection (LC-CAD) to analyze the released monosaccharides. The first step of this NDE-SAH-LC-CAD method aims at removing all compounds that interfere with the subsequent sulphuric acid hydrolysis or with the subsequent chromatographic quantification of the cellulosic and hemicellulosic monosaccharides. This step includes starch hydrolysis with an analytical thermostable α-amylase followed by an extraction of soluble compounds by a Van Soest neutral detergent solution (NDE). The aim of this paper was to assess the precision of this method when choosing fiber sorghum (Sorghum bicolor (L.) Moench), tall fescue (Festuca arundinacea Schreb.) and fiber hemp (Cannabis sativa L.) as representative lignocellulosic biomass. The cellulose content of fiber sorghum, tall fescue and fiber hemp determined by the NDE-SAH-LC-CAD method were 28.7 ± 1.0, 29.7 ± 1.0 and 43.6 ± 1.2g/100g dry matter, respectively, and their hemicellulose content were 18.6 ± 0.5, 16.5 ± 0.5 and 14.5 ± 0.2g/100g dry matter, respectively. Cellulose, mannan and galactan contents were higher in fiber hemp (dicotyledon) as compared to tall fescue and fiber sorghum (monocotyledons). The xylan, arabinan and total hemicellulose contents were higher in tall fescue and fiber sorghum as compared to fiber hemp. The precision of the NDE-SAH-LC-CAD method was better for polysaccharide concentration levels above 1g/100g dry matter. Galactan analysis offered a lower precision, due to a lower CAD response intensity to galactose as compared to the other monosaccharides. The dispersions of the results (expanded uncertainty) of the NDE

  6. Solubility controlled noble gas fractionation during magmatic degassing: Implications for noble gas compositions of primary melts of OIB and MORB

    NASA Astrophysics Data System (ADS)

    Yamamoto, Junji; Burnard, Pete G.

    2005-02-01

    Noble gas abundances in basaltic glasses from ocean islands (OIBs) are generally lower than those of mid-oceanic ridge basalts (MORBs), contrary to most geodynamic models which usually require that the source of OIBs is less degassed (resulting in higher primordial noble gas abundances) and more trace element enriched (resulting in higher radiogenic noble gas abundances) than the MORB source. Therefore, noble gas abundances in OIBs are often thought to have been reduced by extensive gas loss from the magma before eruption. The extent of magmatic degassing can be tested as it will cause characteristic changes in the composition of the volatiles; notably the 4He/ 40Ar* ratio (where 40Ar* is 40Ar corrected for atmospheric contamination) will increase in residual volatiles due to the higher solubility of He relative to Ar. The degree of He-Ar fractionation for a given fraction of gas loss depends on the ratio of the solubilities, S He/S Ar, which is sensitive to (among other things) the CO 2 and H 2O content of the basalt at the time of degassing. From a global database of OIB and MORB glasses, we show that 4He/ 40Ar* ratios of MORB glasses are broadly consistent with degassing of a magma with an initial 40Ar of ≈1.5 × 10 -5 ccSTP/g, i.e., similar to that of the "popping rock." However, OIB glasses generally have lower 40Ar* concentration for a given 4He/ 40Ar*. While this would appear to require lower 40Ar* abundances in the undegassed OIB magmas, the higher volatile contents of OIBs will reduce S He/S Ar (relative to MORBs) during degassing. By modeling S He/S Ar in OIBs, it is possible to show that extensive degassing of OIBs can occur without dramatically increasing the 4He/ 40Ar* ratio. We show that undegassed 40Ar concentrations of OIB magmas were probably similar to those of MORBs.

  7. 75 FR 12737 - Applications To Export Electric Energy; Noble Energy Marketing and Trade Corp.

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-03-17

    ... Applications To Export Electric Energy; Noble Energy Marketing and Trade Corp. AGENCY: Office of Electricity... applications, Noble Energy Marketing and Trade Corp. (NEMT) has applied for authority to transmit electric energy from the United States to Mexico and from the United States to Canada pursuant to section...

  8. RISK REDUCTION VIA GREENER SYNTHESIS OF NOBLE METAL NANOSTRUCTURES AND NANOCOMPOSITES

    EPA Science Inventory

    Aqueous preparation of nanoparticles using vitamins B2 and C which can function both as reducing and capping agents are described. Bulk and shape-controlled synthesis of noble nanostructures via microwave (MW)-assisted spontaneous reduction of noble metal salts using a-D-glucose,...

  9. David Noble's Battle to Defend the 'Sacred Space' of the Classroom.

    ERIC Educational Resources Information Center

    Young, Jeffrey R.

    2000-01-01

    Reports on the crusade of David F. Noble, a history professor at York University (Ontario), against distance education, which he sees as the latest episode in the saga of the corporatization of American higher education. Notes Noble's views on the relationship between politics and technology, intellectual property issues of courseware, and the…

  10. Noble Gas Migration Experiment to Support the Detection of Underground Nuclear Explosions

    SciTech Connect

    Olsen, Khris B.; Kirkham, Randy R.; Woods, Vincent T.; Haas, Derek A.; Hayes, James C.; Bowyer, Ted W.; Mendoza, Donaldo P.; Lowrey, Justin D.; Lukins, Craig D.; Suarez, Reynold; Humble, Paul H.; Ellefson, Mark D.; Ripplinger, Mike D.; Zhong, Lirong; Mitroshkov, Alexandre V.; Aalseth, Craig E.; Prinke, Amanda M.; Mace, Emily K.; McIntyre, Justin I.; Stewart, Timothy L.; Mackley, Rob D.; Milbrath, Brian D.; Emer, Dudley; Biegalski, S.

    2016-03-01

    A Noble Gas Migration Experiment (NGME) funded by the National Center for Nuclear Security and conducted at the Nevada National Security Site (NNSS) in collaboration with Lawrence Livermore national Laboratory and National Security Technology provided critical on-site inspection (OSI) information related to the detection of an underground nuclear explosion (UNE) event using noble gas signatures.

  11. Noble metal-free hydrogen evolution catalysts for water splitting.

    PubMed

    Zou, Xiaoxin; Zhang, Yu

    2015-08-07

    Sustainable hydrogen production is an essential prerequisite of a future hydrogen economy. Water electrolysis driven by renewable resource-derived electricity and direct solar-to-hydrogen conversion based on photochemical and photoelectrochemical water splitting are promising pathways for sustainable hydrogen production. All these techniques require, among many things, highly active noble metal-free hydrogen evolution catalysts to make the water splitting process more energy-efficient and economical. In this review, we highlight the recent research efforts toward the synthesis of noble metal-free electrocatalysts, especially at the nanoscale, and their catalytic properties for the hydrogen evolution reaction (HER). We review several important kinds of heterogeneous non-precious metal electrocatalysts, including metal sulfides, metal selenides, metal carbides, metal nitrides, metal phosphides, and heteroatom-doped nanocarbons. In the discussion, emphasis is given to the synthetic methods of these HER electrocatalysts, the strategies of performance improvement, and the structure/composition-catalytic activity relationship. We also summarize some important examples showing that non-Pt HER electrocatalysts could serve as efficient cocatalysts for promoting direct solar-to-hydrogen conversion in both photochemical and photoelectrochemical water splitting systems, when combined with suitable semiconductor photocatalysts.

  12. Interaction of the Fe + cation with heavy noble gas atoms

    NASA Astrophysics Data System (ADS)

    Heinemann, Christoph; Schwarz, Joseph; Koch, Wolfram; Schwarz, Helmut

    1995-09-01

    The diatomic iron-noble gas complexes FeAr+, FeKr+, FeXe+, and FeRn+ have been theoretically investigated by means of quantum-chemical calculations including an extensive treatment of electron correlation. Potential energy curves and spectroscopic constants for the lowest 4Δ and 6Δ states are derived from an open-shell coupled-cluster approach and the relative energies of all seven low-lying electronic states are evaluated by the multireference configuration interaction method. While in FeAr+ the lowest quartet and sextet states are found to be energetically almost degenerate, the heavier Fe+-noble gas molecules are predicted to exhibit 4Φ ground states. From a qualitative point of view bonding in these species is shown to be electrostatic in origin with intrinsically higher interaction energies for the quartet as compared to the sextet states. For calibration purposes, also an accurate calculation of the 4F(4s03d7)-6D(4s13d6) energy difference in the atomic Fe+ cation is provided.

  13. Isotopic and noble gas geochemistry in geothermal research

    SciTech Connect

    Kennedy, B.M.; DePaolo, D.J.

    1997-12-31

    The objective of this program is to provide, through isotopic analyses of fluids, fluid inclusions, and rocks and minerals coupled with improved methods for geochemical data analysis, needed information regarding sources of geothermal heat and fluids, the spatial distribution of fluid types, subsurface flow, water-rock reaction paths and rates, and the temporal evolution of geothermal systems. Isotopic studies of geothermal fluids have previously been limited to the light stable isotopes of H, C, and O. However, other isotopic systems such as the noble gases (He, Ne, Ar, Kr and Xe) and reactive elements (e.g. B, N, S, Sr and Pb) are complementary and may even be more important in some geothermal systems. The chemistry and isotopic composition of a fluid moving through the crust will change in space and time in response to varying chemical and physical parameters or by mixing with additional fluids. The chemically inert noble gases often see through these variations, making them excellent tracers for heat and fluid sources. Whereas, the isotopic compositions of reactive elements are useful tools in characterizing water-rock interaction and modeling the movement of fluids through a geothermal reservoir.

  14. Plasmon resonances in linear noble-metal chains

    NASA Astrophysics Data System (ADS)

    Gao, Bin; Ruud, Kenneth; Luo, Yi

    2012-11-01

    The electronic excitations of three noble-metall chains—copper, silver, and gold—have been investigated at the time-dependent density functional theory level. The reduced single-electron density matrix is propagated according to the Liouville-von Neumann equation in the real-time domain after an impulse excitation. The propagation in the real-time domain enables us to investigate the formation and size evolution of electronic excitations in these metallic chains with different number of atoms, up to a total of 26 atoms. The longitudinal oscillations at lower excitation energies are dominated by s → p transitions in these chains and have collective or central resonances, while the first peak involving d → p transitions in the longitudinal mode appears at a higher excitation energy and shows collective resonances. In the transverse oscillations, there are in most cases d → p transitions in each resonance, which can be attributed to either central or end resonances. Convergence of the oscillations, in particular those involving the collective and central resonances in the three noble-metal chains can only be observed for chains with 18 atoms or more. Different spectroscopic characteristics among these three metallic chains can be attributed to their different electronic structures, in particular the relativistic effects in the gold chains have a dramatic effect on their electronic structures and excitations.

  15. Solubilities of nitrogen and noble gases in basalt melt

    NASA Technical Reports Server (NTRS)

    Miyazaki, A.; Hiyagon, H.; Sugiura, N.

    1994-01-01

    Nitrogen and noble gases are important tracers in geochemistry and chosmochemistry. Compared to noble gases, however, physicochemical properties of nitrogen, such as solubility in melt or melt/silicate partition, are not well known. Solubility of nitrogen in basalt melt depends on redox condition of the atmosphere. For example, solubility of nitrogen in E chondrite melt under reducing conditions is as high as 2 mol percent at 1500 C, suggesting that nitrogen is chemically dissolved in silicate melts, i.e., being dissolved as free anions or replacing oxygen sites in silicate network. However, the solubility and the dissolution mechanism of nitrogen under oxidizing conditions are not well investigated. To obtain nitrogen solubility in silicate melts under various redox conditions and to understand its mechanism, we are conducting experiments by using (15)N(15)N-labeled nitrogen gas. This makes it easy to distinguish dissolved nitrogen from later contamination of atmospheric nitrogen, and hence enables us to measure the nitrogen solubility accurately. As a preliminary experiment, we have measured solubility of nitrogen in basalt melt under the atmospheric oxygen pressure.

  16. Shock Reflection in a Binary Mixture of Noble Gases

    NASA Astrophysics Data System (ADS)

    Whitlock, S. T.; Baganoff, D.

    1996-11-01

    The standard implementation of Bird's Direct Simulation Monte Carlo (DSMC) method for the simulation of multiple-specie flows uses single-specie transport data as input to an ad hoc combining formula to define parameters used in binary collisions between non-like species. To ascertain the suitability of this approach, we focus on the details of translational nonequilibrium in the flow of a binary mixture of noble gases. Existing experimental results for the one-dimensional reflection of a shock wave in a mixture of helium (He) and xenon (Xe) yield a standard of comparison. The molecular weight and diameter of He:Xe are sufficiently disparate so that the relevant time scales of the reflection process are distinct. Simulations are performed on the Intel Paragon using an adaptation of the DSMC method suitable for the parallel computing environment. Using the best characterizations of noble gas intermolecular potentials that have been published to date, we are able to produce simulations of the reflection process which compare favorably with experiment over a range of Xe concentrations. Investigations of various combining rules to arrive at non-like specie collision parameters indicate that any reasonable combining rule works provided that the single-specie data is physically realistic.

  17. Noble Metal Arsenides and Gold Inclusions in Northwest Africa 8186

    NASA Technical Reports Server (NTRS)

    Srinivasan, P.; McCubbin, F. M.; Rahman, Z.; Keller, L. P.; Agee, C. B.

    2016-01-01

    CK carbonaceous chondrites are a highly thermally altered group of carbonaceous chondrites, experiencing temperatures ranging between approx.576-867 C. Additionally, the mineralogy of the CK chondrites record the highest overall oxygen fugacity of all chondrites, above the fayalite-magnetite-quartz (FMQ) buffer. Metallic Fe-Ni is extremely rare in CK chondrites, but magnetite and Fe,Ni sulfides are commonly observed. Noble metal-rich inclusions have previously been found in some magnetite and sulfide grains. These arsenides, tellurides, and sulfides, which contain varying amounts of Pt, Ru, Os, Te, As, Ir, and S, are thought to form either by condensation from a solar gas, or by exsolution during metamorphism on the chondritic parent body. Northwest Africa (NWA) 8186 is a highly metamorphosed CK chondrite. This meteorite is predominately composed of NiO-rich forsteritic olivine (Fo65), with lesser amounts of plagioclase (An52), augite (Fs11Wo49), magnetite (with exsolved titanomagnetite, hercynite, and titanohematite), monosulfide solid solution (with exsolved pentlandite), and the phosphate minerals Cl-apatite and merrillite. This meteorite contains coarse-grained, homogeneous silicates, and has 120deg triple junctions between mineral phases, which indicates a high degree of thermal metamorphism. The presence of NiO-rich olivine, oxides phases all bearing Fe3+, and the absence of metal, are consistent with an oxygen fugacity above the FMQ buffer. We also observed noble metal-rich phases within sulfide grains in NWA 8186, which are the primary focus of the present study.

  18. Exploring the Effects on Lipid Bilayer Induced by Noble Gases via Molecular Dynamics Simulations

    NASA Astrophysics Data System (ADS)

    Chen, Junlang; Chen, Liang; Wang, Yu; Wang, Xiaogang; Zeng, Songwei

    2015-11-01

    Noble gases seem to have no significant effect on the anesthetic targets due to their simple, spherical shape. However, xenon has strong narcotic efficacy and can be used clinically, while other noble gases cannot. The mechanism remains unclear. Here, we performed molecular dynamics simulations on phospholipid bilayers with four kinds of noble gases to elucidate the difference of their effects on the membrane. Our results showed that the sequence of effects on membrane exerted by noble gases from weak to strong was Ne, Ar, Kr and Xe, the same order as their relative narcotic potencies as well as their lipid/water partition percentages. Compared with the other three kinds of noble gases, more xenon molecules were distributed between the lipid tails and headgroups, resulting in membrane’s lateral expansion and lipid tail disorder. It may contribute to xenon’s strong anesthetic potency. The results are well consistent with the membrane mediated mechanism of general anesthesia.

  19. Noble gases, K, U, Th, and Pb in native gold

    NASA Astrophysics Data System (ADS)

    Engster, O.; Niedermann, S.; Thalmann, C.; Frei, R.; Kramers, J.; KräHenbühl, U.; Liu, Y. Z.; Hofmann, B.; Boer, R. H.; Reimold, W. U.; Bruno, L.

    1995-12-01

    We present determinations of the noble gas and Pb isotopic abundances and of K, Th, and U concentrations of native gold. Our results demonstrate that gold is an excellent carrier for crustal volatiles, but direct dating of gold using the U, Th-4He, 40K-40Ar, and U fission Xe methods was not successful for various reasons. The main significance of this work is the great sensitivity of gold for trapped gases as well as for gases that were produced in situ which gives the prospects of using gold and its fluid and solid inclusions for the study of paleogas composition. Numerous nuclear effects characterize the noble gas inventory of placer gold from Switzerland and Italy, vein gold from Italy, South Africa, and Venezuela, and lode gold from South Africa. The degassing patterns obtained by mass spectrometry show a low-temperature release of volatiles around 500°C from fluid inclusions mainly in vein gold and a high-temperature release from solid inclusions and the gold itself. The low-temperature volatiles represent species that were trapped when the gold crystallized. We investigated the following trapped species: the isotopes of He, Ne, Ar, Kr, Xe, and Pb, and the abundances of K, U, Th, H2O, and CO2. The crustal gases trapped by gold comprise 3He from 6Li(n,α)3H → β- → 3He, 4He and 40Ar from the U, Th, and K decay, and Xe from 238U fission. We observe 4He/40Ar = 3.9 for the radiogenic trapped gases of tertiary gold and a ratio of 1.4 for Archean gold. These ratios are consistent with the production ratios from U and K at the respective times and demonstrate that gold can be used as a sampler of ancient atmospheric gases. The concentrations of U and Th range from a few parts per billion to a few parts per million, and those of K and Pb range up to some tens of parts per million. The antiquity of trapped Pb is indicated by the Pb-Pb model age of about 3000 Ma for the lead extracted from vein gold and quartz of the Lily gold mine (South Africa). Gold also

  20. Using of liquid chromatography coupled with diode array detector for determination of naphthoquinones in plants and for investigation of influence of pH of cultivation medium on content of plumbagin in Dionaea muscipula.

    PubMed

    Babula, Petr; Mikelova, Radka; Adam, Vojtech; Kizek, Rene; Havel, Ladislav; Sladky, Zdenek

    2006-09-14

    The interest of many investigators in naphthoquinones is due to their broad-range of biological actions from phytotoxic to fungicidal. The main aim of this work was to investigate the influence of different pH values of cultivation medium on naphthoquinone content in Dionaea muscipula. For this purpose, we optimized the simultaneous analysis of the most commonly occurring naphthoquinones (1,4-naphthoquinone, lawsone, juglone and plumbagin) by high performance liquid chromatography coupled with diode array detector (HPLC-DAD). The most suitable chromatographic conditions were as follows: mobile phase: 0.1 mol l-1 acetic acid:methanol in ratio of 33:67 (%, v/v), flow rate: 0.75 ml min-1 and temperature: 42 degrees C. Moreover, we looked for the most suitable technique for preparation of plant samples (D. muscipula, Juglans regia, Paulownia tomentosa, Impatience glandulifera, Impatience parviflora, Drosera rotundifolia, Drosera spathulata and Drosera capensis) due to their consequent analysis by HPLC-DAD. It clearly follows from the results obtained that sonication were the most suitable technique for preparation of J. regia plants. We also checked the recoveries of the determined naphthoquinones, which were from 96 to 104%. Finally, we investigated the changes in content of plumbagin in D. muscipula plants according to different pH of cultivation medium. The content increased with increasing pH up to 5 and, then, changed gradually. The lower content of plumbagin at lower pH values was of interest to us. Therefore, we determined the content of this naphthoquinone in the cultivation medium, what has not been studied before. We discovered that the lower tissue content of plumbagin was due to secretion of this naphthoquinone into the cultivation medium.

  1. One- and two-dimensional gas chromatography-mass spectrometry and high performance liquid chromatography-diode-array detector fingerprints of complex substances: a comparison of classification performance of similar, complex Rhizoma Curcumae samples with the aid of chemometrics.

    PubMed

    Ni, Yongnian; Mei, Minghua; Kokot, Serge

    2012-01-27

    Many complex natural or synthetic products are analysed either by the GC-MS (gas chromatography-mass spectrometry) or HPLC-DAD (high performance liquid chromatography-diode-array detector) technique, each of which produces a one-dimensional fingerprint for a given sample. This may be used for classification of different batches of a product. GC-MS and HPLC-DAD analyses of complex, similar substances represented by the three common types of the TCM (traditional Chinese medicine), Rhizoma Curcumae were analysed in the form of one- and two-dimensional matrices firstly with the use of PCA (Principal component analysis), which showed a reasonable separation of the samples for each technique. However, the separation patterns were rather different for each analytical method, and PCA of the combined data matrix showed improved discrimination of the three types of object; close associations between the GC-MS and HPLC-DAD variables were observed. LDA (linear discriminant analysis), BP-ANN (back propagation-artificial neural networks) and LS-SVM (least squares-support vector machine) chemometrics methods were then applied to classify the training and prediction sets. For one-dimensional matrices, all training models indicated that several samples would be misclassified; the same was observed for each prediction set. However, by comparison, in the analysis of the combined matrix, all models gave 100% classification with the training set, and the LS-SVM calibration also produced a 100% result for prediction, with the BP-ANN calibration closely behind. This has important implications for comparing complex substances such as the TCMs because clearly the one-dimensional data matrices alone produce inferior results for training and prediction as compared to the combined data matrix models. Thus, product samples may be misclassified with the use of the one-dimensional data because of insufficient information.

  2. Validated reversed phase-high performance liquid chromatography-diode array detector method for the quantitation of Rutin, a natural immunostimulant for improving survival in aquaculture practice, in toonea sinensis folium

    PubMed Central

    Shen, Yuping; Yin, Huawu; Chen, Bin; Xia, Guohua; Yang, Huan; Jia, Xiaobin

    2012-01-01

    Background: Rutin is a bioflavonoid of strong immunostimulating activity from the Toonea Sinensis Folium, which has shown a significant ability to increase the survival rate of white shrimp with bacterial infection. However, no method for the quantitation of this active ingredient in the herb has been reported to date. Materials and Methods: A reversed phase-high performance liquid chromatography-diode array detector (RP-HPLC-DAD) method was developed to quantify Rutin in the Toonea Sinensis Folium, with the HPLC conditions optimized, followed by validation for linearity, accuracy, precision, limit of detection (LOD), repeatability, and stability. Then, the established method was used to determine the content of Rutin in two samples. Results: The separation was performed on a Waters XBridge Shield RP18 column (150 mm × 4.6 mm, 5 μm) kept at 25°C, and acetonitrile and water containing 0.1% acetate acid (18:82, v / v)-composed mobile phase was constantly driven at 1.0 mL / minute during the analysis. Twenty microliters of sample solution or standard solution were injected into the HPLC system and 254 nm was selected to monitor the separation. A strong linear relationship between the peak area and concentration of Rutin was observed within the range of 0.01044 – 0.2610 mg / mL (r2 = 1.0000). The LOD was 0.03915 μg / mL, and recovery of Rutin was from 97.6 to 99.6%. In addition, the method was also validated to be repeatable, stable, precise, and accurate. Conclusions: An efficient and reliable RP-HPLC-DAD method was established, which could be used for routine analysis of Rutin in Toonea Sinensis Folium and to assist in the quality control of this herb. PMID:22438663

  3. Simultaneous determination of three diarylheptanoids and an alpha-tetralone derivative in the green walnut husks (Juglans regia L.) by high-performance liquid chromatography with photodiode array detector.

    PubMed

    Liu, Junxi; Meng, Min; Li, Chen; Huang, Xinyi; Di, Duolong

    2008-05-09

    By optimizing extraction, separation and analytical conditions, a reliable and accurate high-performance liquid chromatographic (HPLC) method coupled with photodiode array detector (DAD) at room temperature is developed for simultaneous determination of three diarylheptanoids (juglanin A, juglanin B, rhoiptelol) and an alpha-tetralone derivative (regiolone) in methanol extracts from the green walnut husks (Juglans regia L.) The sample pretreatment process involved the reflux extraction using methanol as the extract with a ratio of liquor to sample of 15 mL/g. The separation was achieved on a SinoChrom ODS-AP C(18) column with gradient elution using acetonitrile and 2% (v/v) acetic acid in water. The intra-day and inter-day precision (RSD%) for the analytes ranged from 1.08 to 1.51 and 0.60 to 1.13, respectively. The average recoveries obtained were from 88.4% to 96.2% for the analytes with RSDs below 3.13%. The correlation coefficients of the calibration curve exceeded 0.999. The detection limits were 0.51, 0.25, 0.32 and 0.35 ng at a signal-to-noise ratio of 3, respectively. Quantitative analyses of the samples from different grown sites and in obtained different months showed that the contents of the analytes varied significantly. The method was then successfully applied for the detection and isolation of a new diarylheptanoid derivative in the green walnut husks (J. regia L.). The structure of the new compound was elucidated by various spectroscopic methods including 2D NMR techniques (COSY, HMQC, HMBC), HR-ESI-MS and X-ray single-crystal diffraction analysis.

  4. Sensitive characterization of polyphenolic antioxidants in Polygonatum odoratum by selective solid phase extraction and high performance liquid chromatography-diode array detector-quadrupole time-of-flight tandem mass spectrometry.

    PubMed

    Hu, Xin; Zhao, Huading; Shi, Shuyun; Li, Hui; Zhou, Xiaoling; Jiao, Feipeng; Jiang, Xinyu; Peng, Dongming; Chen, Xiaoqin

    2015-08-10

    The complexity of natural products always leads to the co-elution of interfering compounds with bioactive compounds, which then has a detrimental effect on structural elucidation. Here, a new method, based on selective solid phase extraction combined with 1,1-diphenyl-2-picrylhydrazyl radical (DPPH) spiking and high performance liquid chromatography-diode array detector-quadrupole time-of-flight tandem mass spectrometry (HPLC-DAD-QTOF-MS/MS), is described for sensitive screening, selective extraction and identification of polyphenolic antioxidants in Polygonatum odoratum. First, 25 polyphenolic antioxidants (1-25) were screened by DPPH spiking with HPLC. Second, polydopamine coated Fe3O4 microspheres (Fe3O4@PDA) were prepared to selectively extract target antioxidants with extraction efficiency from 55% to 100% when the amount of Fe3O4@PDA, extraction time, desorption solvent and time were 10mg, 20 min, acetonitrile, and 5 min. Third, 25 antioxidants (10 cinnamides and 15 homoisoflavanones) were identified by HPLC-DAD-QTOF-MS/MS. Furthermore, the DPPH scavenging activities of purified compounds (IC50, 1.6-32.8 μg/mL) validated the method. Among the identified antioxidants, four of them (12, 13, 18 and 19) were new compounds, four of them (2, 4, 8 and 14) were first obtained from family Liliaceae, five of them (1, 3, 5, 7 and 9) were first reported in genus Polygonatum, while one compound (24) was first identified in this species. The results indicated that the proposed method was an efficient and sensitive approach to explore polyphenolic antioxidants from complex natural products.

  5. High-speed counter-current chromatography coupled online to high performance liquid chromatography-diode array detector-mass spectrometry for purification, analysis and identification of target compounds from natural products.

    PubMed

    Liang, Xuejuan; Zhang, Yuping; Chen, Wei; Cai, Ping; Zhang, Shuihan; Chen, Xiaoqin; Shi, Shuyun

    2015-03-13

    A challenge in coupling high-speed counter-current chromatography (HSCCC) online with high performance liquid chromatography (HPLC) for purity analysis was their time incompatibility. Consequently, HSCCC-HPLC was conducted by either controlling HPLC analysis time and HSCCC flow rate or using stop-and-go scheme. For natural products containing compounds with a wide range of polarities, the former would optimize experimental conditions, while the latter required more time. Here, a novel HSCCC-HPLC-diode array detector-mass spectrometry (HSCCC-HPLC-DAD-MS) was developed for undisrupted purification, analysis and identification of multi-compounds from natural products. Two six-port injection valves and a six-port switching valve were used as interface for collecting key HSCCC effluents alternatively for HPLC-DAD-MS analysis and identification. The ethyl acetate extract of Malus doumeri was performed on the hyphenated system to verify its efficacy. Five main flavonoids, 3-hydroxyphloridzin (1), phloridzin (2), 4',6'-dihydroxyhydrochalcone-2'-O-β-D-glucopyranoside (3, first found in M. doumeri), phloretin (4), and chrysin (5), were purified with purities over 99% by extrusion elution and/or stepwise elution mode in two-step HSCCC, and 25mM ammonium acetate solution was selected instead of water to depress emulsification in the first HSCCC. The online system shortened manipulation time largely compared with off-line analysis procedure and stop-and-go scheme. The results indicated that the present method could serve as a simple, rapid and effective way to achieve target compounds with high purity from natural products.

  6. MicroBooNE Detector Move

    ScienceCinema

    Flemming, Bonnie; Rameika, Gina

    2016-07-12

    On Monday, June 23, 2014 the MicroBooNE detector -- a 30-ton vessel that will be used to study ghostly particles called neutrinos -- was transported three miles across the Fermilab site and gently lowered into the laboratory's Liquid-Argon Test Facility. This video documents that move, some taken with time-lapse camerad, and shows the process of getting the MicroBooNE detector to its new home.

  7. MicroBooNE Detector Move

    SciTech Connect

    Flemming, Bonnie; Rameika, Gina

    2014-06-25

    On Monday, June 23, 2014 the MicroBooNE detector -- a 30-ton vessel that will be used to study ghostly particles called neutrinos -- was transported three miles across the Fermilab site and gently lowered into the laboratory's Liquid-Argon Test Facility. This video documents that move, some taken with time-lapse camerad, and shows the process of getting the MicroBooNE detector to its new home.

  8. Technique for detecting liquid metal leaks

    DOEpatents

    Bauerle, James E.

    1979-01-01

    In a system employing flowing liquid metal as a heat transfer medium in contact with tubular members containing a working fluid, i.e., steam, liquid metal leaks through the wall of the tubular member are detected by dislodging the liquid metal compounds forming in the tubular member at the leak locations and subsequently transporting the dislodged compound in the form of an aerosol to a detector responsive to the liquid metal compound. In the application to a sodium cooled tubular member, the detector would consist of a sodium responsive device, such as a sodium ion detector.

  9. Fiber optic fluid detector

    DOEpatents

    Angel, S. Michael

    1989-01-01

    Particular gases or liquids are detected with a fiber optic element (11, 11a to 11j) having a cladding or coating of a material (23, 23a to 23j) which absorbs the fluid or fluids and which exhibits a change of an optical property, such as index of refraction, light transmissiveness or fluoresence emission, for example, in response to absorption of the fluid. The fluid is sensed by directing light into the fiber optic element and detecting changes in the light, such as exit angle changes for example, that result from the changed optical property of the coating material. The fluid detector (24, 24a to 24j) may be used for such purposes as sensing toxic or explosive gases in the atmosphere, measuring ground water contamination or monitoring fluid flows in industrial processes, among other uses.

  10. Fiber optic fluid detector

    DOEpatents

    Angel, S.M.

    1987-02-27

    Particular gases or liquids are detected with a fiber optic element having a cladding or coating of a material which absorbs the fluid or fluids and which exhibits a change of an optical property, such as index of refraction, light transmissiveness or fluoresence emission, for example, in response to absorption of the fluid. The fluid is sensed by directing light into the fiber optic element and detecting changes in the light, such as exit angle changes for example, that result from the changed optical property of the coating material. The fluid detector may be used for such purposes as sensing toxic or explosive gases in the atmosphere, measuring ground water contamination or monitoring fluid flows in industrial processes, among other uses. 10 figs.

  11. DEVELOPMENT OF A NON-NOBLE METAL HYDROGEN PURIFICATION SYSTEM

    SciTech Connect

    Korinko, P; Kyle Brinkman, K; Thad Adams, T; George Rawls, G

    2008-11-25

    Development of advanced hydrogen separation membranes in support of hydrogen production processes such as coal gasification and as front end gas purifiers for fuel cell based system is paramount to the successful implementation of a national hydrogen economy. Current generation metallic hydrogen separation membranes are based on Pd-alloys. Although the technology has proven successful, at issue is the high cost of palladium. Evaluation of non-noble metal based dense metallic separation membranes is currently receiving national and international attention. The focus of the reported work was to develop a scaled reactor with a VNi-Ti alloy membrane to replace a production Pd-alloy tube-type purification/diffuser system.

  12. Seeded Growth Route to Noble Calcium Carbonate Nanocrystal

    PubMed Central

    Islam, Aminul; Teo, Siow Hwa; Rahman, M. Aminur; Taufiq-Yap, Yun Hin

    2015-01-01

    A solution-phase route has been considered as the most promising route to synthesize noble nanostructures. A majority of their synthesis approaches of calcium carbonate (CaCO3) are based on either using fungi or the CO2 bubbling methods. Here, we approached the preparation of nano-precipitated calcium carbonate single crystal from salmacis sphaeroides in the presence of zwitterionic or cationic biosurfactants without external source of CO2. The calcium carbonate crystals were rhombohedron structure and regularly shaped with side dimension ranging from 33–41 nm. The high degree of morphological control of CaCO3 nanocrystals suggested that surfactants are capable of strongly interacting with the CaCO3 surface and control the nucleation and growth direction of calcium carbonate nanocrystals. Finally, the mechanism of formation of nanocrystals in light of proposed routes was also discussed. PMID:26700479

  13. High-pressure synthesis of noble metal hydrides

    NASA Astrophysics Data System (ADS)

    Donnerer, Christian; Scheler, Thomas; Gregoryanz, Eugene

    2013-04-01

    The formation of hydride phases in the noble metals copper, silver, and gold was investigated by in situ x-ray diffraction at high hydrogen pressures. In the case of copper, a novel hexagonal hydride phase, Cu2H, was synthesised at pressures above 18.6 GPa. This compound exhibits an anti-CdI2-type structure, where hydrogen atoms occupy every second layer of octahedral interstitial sites. In contrast to chemically produced CuH, this phase does not show a change in compressibility compared to pure copper. Furthermore, repeated compression (after decomposition of Cu2H) led to the formation of cubic copper hydride at 12.5 GPa, a phenomenon attributed to an alteration of the microstructure during dehydrogenation. No hydrides of silver (up to 87 GPa) or gold (up to 113 GPa) were found at both room and high temperatures.

  14. Seeded optically driven avalanche ionization in molecular and noble gases

    NASA Astrophysics Data System (ADS)

    Polynkin, Pavel; Pasenhow, Bernard; Driscoll, Nicholas; Scheller, Maik; Wright, Ewan M.; Moloney, Jerome V.

    2012-10-01

    We report experimental and numerical results on the dual laser-pulse plasma excitation in molecular and noble gases at atmospheric pressure. Dilute plasma channels generated through filamentation of ultraintense femtosecond laser pulses in air, argon, and helium are densified through the application of multijoule nanosecond heater pulses. Plasma densification in molecular gases is always accompanied by the fragmentation of the plasma channels into discrete bubbles, while in atomic gases, under certain conditions, the densified channels remain smooth and continuous. The densification effect in atomic gases persists through considerably longer delays between the femtosecond and nanosecond pulses compared to that in molecular gases. Using rate equations we trace this difference in the temporal dynamics of densification to the different cooling mechanisms operative in atomic and molecular cases.

  15. Noble gases in the howardites Bholghati and Kapoeta

    NASA Technical Reports Server (NTRS)

    Swindle, T. D.; Hohenberg, C. M.; Nickols, R. H.; Olinger, C.; Garrison, D. H.; Goswami, J. N.

    1990-01-01

    Analyses of noble gases in whole rock samples of the howardites Bholghati and Kapoeta and grain-size separates of Kapoeta yield evidence for excesses of the Xe isotopes Xe-129 , Xe-131, Xe-132, Xe-134, and Xe-136 in a low-temperture component, similar to lunar excess fission Xe. Such a component may be able to provide chronometric information if the relative abundances of radioactive progenitors (I-129, Pu-244, and U-238) can be determined, but the isotopic spectra obtained are not sufficiently precise to do so. Eucritic clast BH-5 in Bholghati contains Xe produced in situ by the decay of Pu-244. Calculated fission Xe retention ages are 30-70 Ma after the formation of the solar system, consistent with the apparent presence of Sm-146 decay products. Both the clast and the matrix of Bholghati have K-Ar ages of about 2 Ga, suggesting a common thermal event at least that recently.

  16. Structural Measurements from Images of Noble Gas Diffusion

    NASA Astrophysics Data System (ADS)

    Cadman, Robert V.; Kadlecek, Stephen J.; Emami, Kiarash; MacDuffie Woodburn, John; Vahdat, Vahid; Ishii, Masaru; Rizi, Rahim R.

    2009-03-01

    Magnetic resonance imaging of externally polarized noble gases such as ^3He has been used for pulmonary imaging for more than a decade. Because gas diffusion is impeded by the alveoli, the diffusion coefficient of gas in the lung, measured on a time scale of milliseconds, is reduced compared to that of the same gas mixture in the absence of restrictions. When the alveolar walls decay, as in emphysema, diffusivity in the lung increases. In this paper, the relationship between diffusion measurements and the size of the restricting structures will be discussed. The simple case of diffusion in an impermeable cylinder, a structure similar to the upper respiratory airways in mammals, has been studied. A procedure will be presented by which airways of order 2 mm in diameter may be accurately measured; demonstration experiments with plastic tubes will also be presented. The additional developments needed before this technique becomes practical will be briefly discussed.

  17. Seeded Growth Route to Noble Calcium Carbonate Nanocrystal.

    PubMed

    Islam, Aminul; Teo, Siow Hwa; Rahman, M Aminur; Taufiq-Yap, Yun Hin

    2015-01-01

    A solution-phase route has been considered as the most promising route to synthesize noble nanostructures. A majority of their synthesis approaches of calcium carbonate (CaCO3) are based on either using fungi or the CO2 bubbling methods. Here, we approached the preparation of nano-precipitated calcium carbonate single crystal from salmacis sphaeroides in the presence of zwitterionic or cationic biosurfactants without external source of CO2. The calcium carbonate crystals were rhombohedron structure and regularly shaped with side dimension ranging from 33-41 nm. The high degree of morphological control of CaCO3 nanocrystals suggested that surfactants are capable of strongly interacting with the CaCO3 surface and control the nucleation and growth direction of calcium carbonate nanocrystals. Finally, the mechanism of formation of nanocrystals in light of proposed routes was also discussed.

  18. Noble gases and cosmogenic radionuclides in the Eltanin Pacific meteorite

    SciTech Connect

    Bogard, D D; Garrison, D H; Caffee, M W; Kyte, F; Nishiizumi, K

    2000-01-14

    A 1.5 cm long, 1.2 g specimen of the Eltanin meteorite was found at 10.97 m depth in Polarstern piston core PS2704-1. The early studies indicated that the small fragments of the Eltanin meteorite was debris from a km-sized asteroid which impacted into the deep-ocean basin. In this study, the authors measured {sup 39}Ar-{sup 40}Ar age, noble gases, and cosmogenic radionuclides in splits of specimen as a part of consortium studies of Eltanin meteorite. They concluded that the specimen was about 3 m deep from the asteroid surface. The exposure age of the Eltanin asteroid was about 20 Myr.

  19. High-pressure synthesis of noble metal hydrides.

    PubMed

    Donnerer, Christian; Scheler, Thomas; Gregoryanz, Eugene

    2013-04-07

    The formation of hydride phases in the noble metals copper, silver, and gold was investigated by in situ x-ray diffraction at high hydrogen pressures. In the case of copper, a novel hexagonal hydride phase, Cu2H, was synthesised at pressures above 18.6 GPa. This compound exhibits an anti-CdI2-type structure, where hydrogen atoms occupy every second layer of octahedral interstitial sites. In contrast to chemically produced CuH, this phase does not show a change in compressibility compared to pure copper. Furthermore, repeated compression (after decomposition of Cu2H) led to the formation of cubic copper hydride at 12.5 GPa, a phenomenon attributed to an alteration of the microstructure during dehydrogenation. No hydrides of silver (up to 87 GPa) or gold (up to 113 GPa) were found at both room and high temperatures.

  20. Noble-metal nanostructures on carburized W(110)

    NASA Astrophysics Data System (ADS)

    Bachmann, Magdalena; Memmel, Norbert; Bertel, Erminald

    2011-07-01

    Noble metal nanostructures of Au, Ag and Cu were prepared on two types of carbon-modified W(110) surfaces-R(15 × 12) and R(15 × 3)-and investigated by means of scanning tunneling microscopy. For all deposited metals qualitatively the same behaviour is observed: On the R(15 × 12)-template always isotropic clusters are formed. In contrast, on the R(15 × 3)-substrate the anisotropy of the nanostructures can be tuned from clusters at low temperatures via thin nanowires to thicker nanobars at high deposition temperatures. At intermediate temperatures on the R(15 × 3) the anisotropic Au nanowires arrange themselves into straight lines along domain boundaries induced by deposition of the Au metal. Similarities and differences to Au nanostructures as recently reported by Varykhalov et al. [A. Varykhalov, O. Rader, W. Gudat. Physical Review B 77, 035412 (2008).] are discussed.