Sentinel lymph node biopsy in the management of early-stage cervical carcinoma.
Diaz, John P; Gemignani, Mary L; Pandit-Taskar, Neeta; Park, Kay J; Murray, Melissa P; Chi, Dennis S; Sonoda, Yukio; Barakat, Richard R; Abu-Rustum, Nadeem R
2011-03-01
We aimed to determine the sentinel lymph node detection rates, accuracy in predicting the status of lymph node metastasis, and if pathologic ultrastaging improves the detection of micrometastases and isolated tumor cells at the time of primary surgery for cervical cancer. A prospective, non-randomized study of women with early-stage (FIGO stage IA1 with lymphovascular space involvement--IIA) cervical carcinoma was conducted from June 2003 to August 2009. All patients underwent an intraoperative intracervical blue dye injection. Patients who underwent a preoperative lymphoscintigraphy received a 99m Tc sulfur colloid injection in addition. All patients underwent sentinel lymph node (SLN) identification followed by a complete pelvic node and parametrial dissection. SLN were evaluated using our institutional protocol that included pathologic ultrastaging. SLN mapping was successful in 77 (95%) of 81 patients. A total of 316 SLN were identified, with a median of 3 SLN per patient (range, 0-10 SLN). The majority (85%) of SLN were located at three main sites: the external iliac (35%); internal iliac (30%); and obturator (20%). Positive lymph nodes (LN) were identified in 26 (32%) patients, including 21 patients with positive SLN. Fifteen of 21 patients (71%) had SLN metastasis detected on routine processing. SLN ultrastaging detected metastasis in an additional 6/21 patients (29%). Two patients had grossly positive LN at exploration, and mapping was abandoned. Three of 26 (12%) patients had successful SLN mapping; however, the SLN failed to identify the metastatic LN. Of these 3 false negative cases, 2 patients had a metastatic parametrial node as the only positive LN with multiple negative pelvic nodes including negative SLN. One patient with stage IA1 disease and lymphovascular invasion had unilateral SLN mapping and a metastatic common iliac LN identified on completion lymphadenectomy of the contralateral side that did not map. The 4 (5%) patients with unsuccessful mapping included 1 who had grossly positive nodes identified at the time of laparotomy; the remaining 3 occurred during each surgeon's initial SLN mapping learning phase. SLN mapping in early-stage cervical carcinoma yields high detection rates. Ultrastaging improves micrometastasis detection. Parametrectomy and side-specific lymphadenectomy (in cases of failed mapping) remain important components of the surgical management of selected cases. Copyright © 2010 Elsevier Inc. All rights reserved.
The efficacy of sentinel lymph node mapping with indocyanine green in cervical cancer.
Kim, Ju-Hyun; Kim, Dae-Yeon; Suh, Dae-Shik; Kim, Jong-Hyeok; Kim, Yong-Man; Kim, Young-Tak; Nam, Joo-Hyun
2018-03-09
Lymph node metastasis is a significant predictive factor for disease recurrence and survival in cervical cancer patients. Given the importance of lymph node metastasis, it is imperative that patients harboring metastasis are identified and can undergo appropriate treatment. Sentinel lymph node (SLN) mapping has drawn attention as a lymph node mapping technique. We evaluated the feasibility and efficacy of (SLN) mapping using indocyanine green (ICG) in cervical cancer. We performed a single-center, retrospective study of 103 surgically treated cervical cancer patients who underwent SLN mapping. After using ICG to detect SLN during surgery, we removed the SLNs followed by laparoscopic or robotic-assisted radical surgery and bilateral pelvic lymphadenectomy. Stage IB1 was the most common (61.17%). At least one SLN was detected in all cases. Eighty-eight patients (85.44%) had bilateral pelvic SLNs. The mean number of SLN per patient was 2.34. The side-specific sensitivity was 71.43%, the specificity was 100%, the negative predictive value (NPV) was 93.98%, and the false negative rate (FNR) was 28.57%. In cases of tumors smaller than 2 cm with negative lymph node metastasis on imaging, the study revealed a side-specific sensitivity of 100%, a specificity of 100%, a NPV of 100%, and a FNR of 0%. Large tumor size (≥ 4 cm), a previous history of a loop electrosurgical excision procedure (LEEP), depth of invasion (≥ 50%), the microscopic parametrial (PM) invasion, and vaginal extension were significantly associated with the false-negative detection of SLN. Moreover, the microscopic PM invasion was the only risk factor of the false-negative detection of SLN in multivariate analysis. SLN mapping with ICG in cervical cancer is feasible and has high detection rate. The sensitivity of 100% was high enough to perform SLN biopsy alone in an early stage in which the tumor is less than 2 cm, with no lymphadenopathy on image examination. However, for large or invasive tumors, we would have to be cautious about performing SLN biopsy alone. Retrospectively registered 2017-0600.
Predictive model of outcome of targeted nodal assessment in colorectal cancer.
Nissan, Aviram; Protic, Mladjan; Bilchik, Anton; Eberhardt, John; Peoples, George E; Stojadinovic, Alexander
2010-02-01
Improvement in staging accuracy is the principal aim of targeted nodal assessment in colorectal carcinoma. Technical factors independently predictive of false negative (FN) sentinel lymph node (SLN) mapping should be identified to facilitate operative decision making. To define independent predictors of FN SLN mapping and to develop a predictive model that could support surgical decisions. Data was analyzed from 2 completed prospective clinical trials involving 278 patients with colorectal carcinoma undergoing SLN mapping. Clinical outcome of interest was FN SLN(s), defined as one(s) with no apparent tumor cells in the presence of non-SLN metastases. To assess the independent predictive effect of a covariate for a nominal response (FN SLN), a logistic regression model was constructed and parameters estimated using maximum likelihood. A probabilistic Bayesian model was also trained and cross validated using 10-fold train-and-test sets to predict FN SLN mapping. Area under the curve (AUC) from receiver operating characteristics curves of these predictions was calculated to determine the predictive value of the model. Number of SLNs (<3; P = 0.03) and tumor-replaced nodes (P < 0.01) independently predicted FN SLN. Cross validation of the model created with Bayesian Network Analysis effectively predicted FN SLN (area under the curve = 0.84-0.86). The positive and negative predictive values of the model are 83% and 97%, respectively. This study supports a minimum threshold of 3 nodes for targeted nodal assessment in colorectal cancer, and establishes sufficient basis to conclude that SLN mapping and biopsy cannot be justified in the presence of clinically apparent tumor-replaced nodes.
Use of sentinel node mapping for cancer of the colon: 'to map or not to map".
Thomas, Kristen A; Lechner, Jonathan; Shen, Perry; Waters, Gregory S; Geisinger, Kim R; Levine, Edward A
2006-07-01
Sentinel lymph node (SLN) mapping has become a cornerstone of oncologic surgery because it is a proven method for identifying nodal disease in melanoma and breast cancer. In addition, it can ameliorate the surgical morbidity secondary to lymphadenectomy. However, experience with SLN mapping for carcinoma of the colon and other visceral malignancies is limited. This study represents an update to our initial pilot experience with SLN mapping for carcinoma of the colon. Consenting patients over the age of 18 diagnosed with adenocarcinoma of the colon were included in this study. At the time of operation, 1 to 2 mL of isosulfan blue was injected with a 25-gauge needle into the subserosa at 4 sites around the edge of the palpable tumor. The SLN was identified visually and excised followed by a standard lymphadenectomy and surgical resection. SLNs were evaluated by standard hematoxylin and eosin (H&E) evaluation as well as immunohistochemical (IHC) techniques for carcinoembryonic antigen and cytokeratin if the H&E was negative. Sixty-nine patients underwent SLN mapping. A SLN was identified in 93 per cent (64 of 69) of patients. Nodal metastases were identified in 38 per cent (26 of 69) of patients overall. In 5 patients, the only positive node identified was the SLN, 2 of which were positive by IHC criteria alone. Therefore, 3 per cent (2 of 69) of patients were upstaged by SLN mapping. This technique was 100 per cent specific while being 46 per cent sensitive. Fourteen patients had false-negative SLNs. Metastasis to regional lymph nodes remains the key prognostic factor for colon cancer. SLN mapping is feasible for colon cancer and can identify a subset of patients who could benefit from adjuvant chemotherapy. Although SLN mapping did not alter the surgical management of colon cancer, it does make possible a more focused and cost-effective pathologic evaluation of nodal disease. We do not suggest routine utilization of SLN mapping for colon cancer, but we believe that the data supports proceeding with a national trial.
Foster, Deshka; Choy, Nicole; Porter, Catherine; Ahmed, Shushmita; Wapnir, Irene
2018-03-01
Sentinel lymph node (SLN) resection is imperative for breast cancer staging. Axillary reverse mapping (ARM) can preserve arm draining nodes and lymphatics during surgery. ARM is generally performed with isosulfan blue (ISB), restricting its use for concurrent SLN biopsy. Indocyanine green (ICG) could serve as an alternative to ISB for ARM procedures. SLN mapping and biopsy was performed via periareolar injection of 99 technetium-sulfur colloid ( 99m TcSc, TSC). ISB and ICG were injected in the upper arm. Blue-stained lymphatics or nodes were visualized in the axilla; ICG was identified using the SPY Elite® system. Twenty-three patients underwent SLN biopsy with or without axillary node dissection and ARM procedures. Twenty of these patients had at least one hot node; 12 patients had SLNs that were only hot, 6 hot/blue/fluorescent, and 2 hot/fluorescent. Overall, crossover of ARM agents with SLNs occurred in 8 cases. Inspection of the axillary cavity after SLN biopsy revealed fluorescent lymphatics and nodes remaining in 14 and 7 patients, respectively. Blue lymphatics and blue nodes were detected in fewer cases. Nearly one-third of patients showed crossover between breast and arm draining nodes, which provides insight as to why some patients develop lymphedema symptoms after SLN biopsy. ICG and ISB identify similar numbers of SLNs. As such ICG could substitute for ISB in ARM procedures. © 2017 Wiley Periodicals, Inc.
Co, Michael; Kwong, Ava
2017-04-01
Sentinel lymph node (SLN) biopsy is currently the gold standard of treatment in early breast cancers. Identification of SLNs by preoperative scintigraphy has been carried out to improve the detection of SLNs intraoperatively, but the evidence of its cost-effectiveness is lacking. Here, we analyze the cost-effectiveness of the utilization of scintigraphy in detection of SLNs. Clinical and operative details were retrieved from a prospectively maintained database. The resources and cost data from each patient who had undergone SLN biopsy with preoperative scintigraphy were retrieved. From January 2008 to December 2012, 400 patients underwent SLN biopsy for breast cancer. A total of 329 had preoperative SLN mapping with scintigraphy, Baseline patient demographic data for both arms were comparable. The relapse and recurrence rate of both arms were not statistically different. The detection rate of SLNs of both arms was the same (100%), and there were no grade 2 or above lymphedema in both groups of patients. However, the cost of each patient undergoing SLN mapping was USD $345.8. Preoperative SLN mapping does not improve the SLN detection rate. In addition, it does not affect the surgical outcomes in terms of complication, local relapse, and recurrence. The use of preoperative SLN mapping is no longer cost-effective. Copyright © 2016 Elsevier Inc. All rights reserved.
Beavis, Anna L; Salazar-Marioni, Sergio; Sinno, Abdulrahman K; Stone, Rebecca L; Fader, Amanda N; Santillan-Gomez, Antonio; Tanner, Edward J
2016-11-01
Our study objective was to determine feasibility and mapping rates using indocyanine green (ICG) for sentinel lymph node (SLN) mapping in early-stage cervical cancer. We performed a retrospective review of all women who underwent SLN mapping with ICG during primary surgical management of early-stage cervical cancer by robotic-assisted radical hysterectomy (RA-RH) or fertility-sparing surgery. Patients were treated at two high-volume centers from 10/2012 to 02/2016. Completion pelvic lymphadenectomy was performed after SLN biopsy; additionally, removal of clinically enlarged/suspicious nodes was part of the SLN treatment algorithm. Thirty women with a median age of 42.5 and BMI of 26.5 were included. Most (90%) had stage IB disease, and 67% had squamous histology. RA-RH was performed in 86.7% of cases. One patient underwent fertility-sparing surgery. Median cervical tumor size was 2.0cm. At least one SLN was detected in all cases (100%), with bilateral mapping achieved in 87%. SLN detection was not impacted by tumor size and was most commonly identified in the hypogastric (40.3%), obturator (26.0%), and external iliac (20.8%) regions. Five cases of lymphatic metastasis were identified (16.7%): three in clinically enlarged SLNs, one in a clinically enlarged non-SLN, and one case with cytokeratin positive cells in an SLN. All metastatic disease would have been detected even if full lymphadenectomy had been omitted from our treatment algorithm, CONCLUSIONS: SLN mapping with ICG is feasible and results in high detection rates in women with early-stage cervical cancer. Prospective studies are needed to determine if SLN mapping can replace lymphadenectomy in this setting. Copyright © 2016 Elsevier Inc. All rights reserved.
Sentinel lymph node mapping in gynecological oncology
Du, Jiang; Li, Yaling; Wang, Qing; Batchu, Nasra; Zou, Junkai; Sun, Chao; Lv, Shulan; Song, Qing; Li, Qiling
2017-01-01
The intraoperative mapping of sentinel lymph nodes (SLNs) is part of the treatment strategy for a number of types of tumor. To retrospectively compare results from the mapping of pelvic SLNs for gynecological oncology, using distinct dyes, the present review was conducted to determine the clinical significance of SLN mapping for gynecological oncology. In addition, the present study aimed at identifying an improved choice for SLN mapping tracers in clinical application. Each dye exhibits demerits when applied in the clinical environment. The combination of radioisotopes and blue dyes was identified to exhibit the most accurate detection rate of SLN drainage of gynecological oncology. However, contrast agents were unable to identify whether a SLN is positive or negative for metastasis prior to pathologic examination; additional studies are required. PMID:29344213
Papadia, Andrea; Gasparri, Maria Luisa; Genoud, Sophie; Bernd, Klaeser; Mueller, Michael D
2017-11-01
The aim of the study was to evaluate the use of PET/CT and/or SLN mapping alone or in combination in cervical cancer patients. Data on stage IA1-IIA cervical cancer patients undergoing PET/CT and SLN mapping were retrospectively collected. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of PET/CT and SLN mapping, alone or in combination, in identifying cervical cancer patients with lymph node metastases were calculated. Sixty patients met the inclusion criteria. PET/CT showed a sensitivity of 68%, a specificity of 84%, a PPV of 61% and a NPV of 88% in detecting lymph nodal metastases. SLN mapping showed a sensitivity of 93%, a specificity of 100%, a PPV of 100% and a NPV of 97%. The combination of PET/CT and SLN mapping showed a sensitivity of 100%, a specificity of 86%, a PPV of 72% and a NPV of 100%. For patients with tumors of >2 cm in diameter, the PET/CT showed a sensitivity of 68%, a specificity of 72%, a PPV of 61% and a NPV of 86%. SLN mapping showed a sensitivity of 93%, a specificity of 100%, a PPV of 100% and a NPV of 95%. The combination of PET/CT and SLN mapping showed a sensitivity of 100%, a specificity of 76%, a PPV of 72% and a NPV of 100%. PET/CT represents a "safety net" that helps the surgeon in identifying metastatic lymph nodes, especially in patients with larger tumors.
Papadia, Andrea; Gasparri, Maria Luisa; Radan, Anda P; Stämpfli, Chantal A L; Rau, Tilman T; Mueller, Michael D
2018-04-24
To evaluate the sensitivity, negative predictive value (NPV) and false-negative (FN) rate of the near infrared (NIR) indocyanine green (ICG) sentinel lymph node (SLN) mapping in patients with poorly differentiated endometrial cancer who have undergone a full pelvic and para-aortic lymphadenectomy after SLN mapping. We performed a retrospective analysis of patients with endometrial cancer undergoing a laparoscopic NIR-ICG SLN mapping followed by a systematic pelvic and para-aortic lymphadenectomy. Inclusion criteria were a grade 3 endometrial cancer or a high-risk histology (papillary serous, clear cell carcinoma, carcinosarcoma, and neuroendocrine carcinoma) and a completion pelvic and para-aortic lymphadenectomy to the renal vessels after SLN mapping. Overall and bilateral detection rates, sensitivity, NPV, and FN rates were calculated. From December 2012 until January 2017, 42 patients fulfilled inclusion criteria. Overall and bilateral detection rates were 100 and 90.5%, respectively. Overall, 23.8% of the patients had lymph node metastases. In one patient, despite negative bilateral pelvic SLNs, a metastatic non-SLN-isolated para-aortic metastasis was detected. This NSLN was clinically suspicious and sent to frozen section analysis during the surgery. FN rate, sensitivity, and NPV were 10, 90, and 97.1%, respectively. For the SLN mapping algorithm, FN rate, sensitivity, and NPV were 0, 100, and 100%, respectively. Laparoscopic NIR-ICG SLN mapping in high-risk endometrial cancer patients has acceptable sensitivity, FN rate, and NPV.
Ducie, Jennifer A; Eriksson, Ane Gerda Zahl; Ali, Narisha; McGree, Michaela E; Weaver, Amy L; Bogani, Giorgio; Cliby, William A; Dowdy, Sean C; Bakkum-Gamez, Jamie N; Soslow, Robert A; Keeney, Gary L; Abu-Rustum, Nadeem R; Mariani, Andrea; Leitao, Mario M
2017-12-01
To determine if a sentinel lymph node (SLN) mapping algorithm will detect metastatic nodal disease in patients with intermediate-/high-risk endometrial carcinoma. Patients were identified and surgically staged at two collaborating institutions. The historical cohort (2004-2008) at one institution included patients undergoing complete pelvic and paraaortic lymphadenectomy to the renal veins (LND cohort). At the second institution an SLN mapping algorithm, including pathologic ultra-staging, was performed (2006-2013) (SLN cohort). Intermediate-risk was defined as endometrioid histology (any grade), ≥50% myometrial invasion; high-risk as serous or clear cell histology (any myometrial invasion). Patients with gross peritoneal disease were excluded. Isolated tumor cells, micro-metastases, and macro-metastases were considered node-positive. We identified 210 patients in the LND cohort, 202 in the SLN cohort. Nodal assessment was performed for most patients. In the intermediate-risk group, stage IIIC disease was diagnosed in 30/107 (28.0%) (LND), 29/82 (35.4%) (SLN) (P=0.28). In the high-risk group, stage IIIC disease was diagnosed in 20/103 (19.4%) (LND), 26 (21.7%) (SLN) (P=0.68). Paraaortic lymph node (LN) assessment was performed significantly more often in intermediate-/high-risk groups in the LND cohort (P<0.001). In the intermediate-risk group, paraaortic LN metastases were detected in 20/96 (20.8%) (LND) vs. 3/28 (10.7%) (SLN) (P=0.23). In the high-risk group, paraaortic LN metastases were detected in 13/82 (15.9%) (LND) and 10/56 (17.9%) (SLN) (%, P=0.76). SLN mapping algorithm provides similar detection rates of stage IIIC endometrial cancer. The SLN algorithm does not compromise overall detection compared to standard LND. Copyright © 2017 Elsevier Inc. All rights reserved.
Sentinel lymph node accumulation of Lymphoseek and Tc-99m-sulfur colloid using a “2-day” protocol☆
Wallace, Anne M.; Hoh, Carl K.; Limmer, Karl K.; Darrah, Denise D.; Schulteis, Gery; Vera, David R.
2014-01-01
Lymphoseek is a receptor-binding radiopharmaceutical specifically designed for sentinel lymph node (SLN) mapping. We conducted a clinical trial which measured the injection site clearance and sentinel lymph node accumulation after a single intradermal injection of Lymphoseek or unfiltered [99mTc]sulfur colloid (TcSC) using a “2-day” protocol for SLN mapping of breast cancer. Eleven patients with breast cancer participated in this study. Five patients received an intradermal administration of 1.0 nmol of 99mTc-labeled Lymphoseek; SLN mapping was performed on four subjects within 19 to 27 h. Six subjects received an intradermal administration of TcSC; SLN mapping was performed on five subjects within 18 to 26 h. Lymphoseek exhibited a significantly (P<.001) faster injection site clearance than TcSC. The mean Lymphoseek clearance half-time was 2.18±1.09 h compared to 57.4±92.8 h for TcSC. The mean sentinel lymph node uptake of Lymphoseek (1.5±1.7%) and TcSC (3.5±3.1%) was statistically equivalent (P=.213). When an intradermal injection is employed, Lymphoseek demonstrated faster injection site clearance than unfiltered [99mTc]sulfur colloid and persistent SLN accumulation for at least 24 h. PMID:19647175
Papadia, Andrea; Gasparri, Maria Luisa; Siegenthaler, Franziska; Imboden, Sara; Mohr, Stefan; Mueller, Michael D
2017-03-01
To compare two surgical strategies used to identify lymph node metastases in patients with preoperative diagnosis of complex atypical hyperplasia (CAH), grade 1 and 2 endometrial cancer (EC). Data on patients with preoperative diagnosis of CAH, grade 1 and 2 EC undergoing laparoscopic indocyanine green (ICG) sentinel lymph node (SLN) mapping followed by frozen section of the uterus were collected. When risk factors were identified at frozen section, patients were subjected to a systematic lymphadenectomy. False negative (FN) rates, negative predictive values (NPV), positive predictive values (PPV) and correlation with stage IIIC EC were calculated for the systematic lymphadenectomy based on frozen section of the uterus and for the SLN mapping. Six (9.5%) out of 63 patients had lymph nodal metastases. Based on frozen section of the uterus, 22 (34.9%) and 15 (22.2%) patients underwent a pelvic and a pelvic and paraaortic lymphadenectomy, respectively. Five patients with stage IIIC disease were identified with a FN rate of 16.7% and a NPV and PPV of 97.6 and 27.3%, respectively. Overall and bilateral detection rates of ICG SLN mapping were 100 and 97.6%, respectively; no FN were recorded. The identification of patients with stage IIIC disease with ICG SLN mapping showed a NPV and PPV of 100%. Correlation between indication to lymphadenectomy and stage IIIC disease was poor (κ = 0.244) when based on frozen section of the uterus and excellent (κ = 1) when based on SLN mapping. ICG SLN mapping reduces the number of unnecessary systematic lymphadenectomies and the risk of underdiagnosing patients with metastatic lymph nodes.
Martinelli, Fabio; Ditto, Antonino; Bogani, Giorgio; Signorelli, Mauro; Chiappa, Valentina; Lorusso, Domenica; Haeusler, Edward; Raspagliesi, Francesco
2017-01-01
To report the detection rate (DR) of sentinel lymph nodes (SLNs) in endometrial cancer (EC) patients after hysteroscopic injection of indocyanine green (ICG) and laparoscopic near-infrared (L-NIR) fluorescence mapping. Prospectively collected data (Canadian Task Force classification II-2). Gynecologic oncology referral center. Consecutive patients with apparent early-stage endometrioid EC scheduled for surgical treatment: total laparoscopic hysterectomy, bilateral salpingo-oophorectomy, SLN mapping. The mapping technique consisted in an intraoperative hysteroscopic peritumoral injection of 5 mg ICG followed by L-NIR fluorescence mapping. Evaluations of the SLN DR and sites of mapping were performed. A total of 57 procedures was performed. Patient mean age was 60 years (range, 28-80) and mean body mass index was 28.2 kg/m 2 (range, 19-43). At least 1 SLN was detected in 89.5% of the whole population (51/57). After the first 16 cases, L-NIR camera technical improvement led to a 95% DR (39/41). The mean number of harvested SLNs was 4.1 (range. 1-8), and in 47% of cases SLNs mapped to aortic nodes (24/51). Bilateral pelvic mapping was found in 74.5% of cases (38/51). Three patients had SLN metastases: 1 in the pelvic area only, 1 both in the pelvic and aortic area, and 1 presented with 2 metastatic aortic SLNs with negative pelvic SLNs. Overall, 2 of 3 node-positive patients (67%) had aortic SLN involvement. No adverse events were reported. Laparoscopic SLN mapping after the hysteroscopic injection of ICG has comparable DRs with both radioactive tracer series and ICG series with cervical injection, overcoming the need for radioactive substances. Hysteroscopic injection leads to a higher mapping in the aortic area compared with cervical injection. Further investigation is warranted on this topic. Copyright © 2016 AAGL. Published by Elsevier Inc. All rights reserved.
Krammer, Julia; Dutschke, Anja; Kaiser, Clemens G; Schnitzer, Andreas; Gerhardt, Axel; Radosa, Julia C; Brade, Joachim; Schoenberg, Stefan O; Wasser, Klaus
2016-01-01
To evaluate whether tumor localization and method of preoperative biopsy affect sentinel lymph node (SLN) detection after periareolar nuclide injection in breast cancer patients. 767 breast cancer patients were retrospectively included. For lymphscintigraphy periareolar nuclide injection was performed and the SLN was located by gamma camera. Patient and tumor characteristics were correlated to the success rate of SLN mapping. SLN marking failed in 9/61 (14.7%) patients with prior vacuum-assisted biopsy and 80/706 (11.3%) patients with prior core needle biopsy. Individually evaluated, biopsy method (p = 0.4) and tumor localization (p = 0.9) did not significantly affect the SLN detection rate. Patients with a vacuum-assisted biopsy of a tumor in the upper outer quadrant had a higher odds ratio of failing in SLN mapping (OR 3.8, p = 0.09) compared to core needle biopsy in the same localization (OR 0.9, p = 0.5). Tumor localization and preoperative biopsy method do not significantly impact SLN mapping with periareolar nuclide injection. However, the failure risk tends to rise if vacuum-assisted biopsy of a tumor in the upper outer quadrant is performed.
Zhao, Xin; Xiao, Dajiang; Ni, Jianming; Zhu, Guochen; Yuan, Yuan; Xu, Ting; Zhang, Yongsheng
2014-11-01
To investigate the clinical value of sentinel lymph node (SLN) detection in laryngeal and hypopharyngeal carcinoma patients with clinically negative neck (cN0) by methylene blue method, radiolabeled tracer method and combination of these two methods. Thirty-three patients with cN0 laryngeal carcinoma and six patients with cN0 hypopharyngeal carcinoma underwent SLN detection using both of methylene blue and radiolabeled tracer method. All these patients were accepted received the injection of radioactive isotope 99 Tc(m)-sulfur colloid (SC) and methylene blue into the carcinoma before surgery, then all these patients underwent intraopertive lymphatic mapping with a handheld gamma-detecting probe and blue-dyed SLN. After the mapping of SLN, selected neck dissections and tumor resections were peformed. The results of SLN detection by radiolabeled tracer, dye and combination of both methods were compared. The detection rate of SLN by radiolabeled tracer, methylene blue and combined method were 89.7%, 79.5%, 92.3% respectively. The number of detected SLN was significantly different between radiolabeled tracer method and combined method, and also between methylene blue method and combined method. The detection rate of methylene blue and radiolabeled tracer method were significantly different from combined method (P < 0.05). Nine patients were found to have lymph node metastasis by final pathological examination. The accuracy and negative rate of SLN detection of the combined method were 97.2% and 11.1%. The combined method using radiolabeled tracer and methylene blue can improve the detection rate and accuracy of sentinel lymph node detection. Furthermore, sentinel lymph node detection can accurately represent the cervical lymph node status in cN0 laryngeal and hypopharyngeal carcinoma.
Takeuchi, Megumi; Sugie, Tomoharu; Abdelazeem, Kassim; Kato, Hironori; Shinkura, Nobuhiko; Takada, Masahiro; Yamashiro, Hiroyasu; Ueno, Takayuki; Toi, Masakazu
2012-01-01
The indocyanine green fluorescence (ICGf) navigation method provides real-time lymphatic mapping and sentinel lymph node (SLN) visualization, which enables the removal of SLNs and their associated lymphatic networks. In this study, we investigated the features of the drainage pathways detected with the ICGf navigation system and the order of metastasis in axillary nodes. From April 2008 to February 2010, 145 patients with clinically node-negative breast cancer underwent SLN surgery with ICGf navigation. The video-recorded data from 79 patients were used for lymphatic mapping analysis. We analyzed 145 patients with clinically node-negative breast cancer who underwent SLN surgery with the ICGf navigation system. Fluorescence-positive SLNs were identified in 144 (99%) of 145 patients. Both single and multiple routes to the axilla were identified in 47% of cases using video-recorded lymphatic mapping data. An internal mammary route was detected in 6% of the cases. Skip metastasis to the second or third SLNs was observed in 6 of the 28 node-positive patients. We also examined the strategy of axillary surgery using the ICGf navigation system. We found that, based on the features of nodal involvement, 4-node resection could provide precise information on the nodal status. The ICGf navigation system may provide a different lymphatic mapping result than computed tomography lymphography in clinically node-negative breast cancer patients. Furthermore, it enables the identification of lymph nodes that do not accumulate indocyanine green or dye adjacent to the SLNs in the sequence of drainage. Knowledge of the order of nodal metastasis as revealed by the ICGf system may help to personalize the surgical treatment of axilla in SLN-positive cases, although additional studies are required. © 2012 Wiley Periodicals, Inc.
Rauch, Philippe; Merlin, Jean-Louis; Leufflen, Lea; Salleron, Julia; Harlé, Alexandre; Olivier, Pierre; Marchal, Frédéric
2016-09-01
Although morbidity is reduced when sentinel lymph node (SLN) biopsy is performed with dual isotopic and blue dye identification, the effectiveness of adding blue dye to radioisotope remains debated because side effects including anaphylactic reactions. Using data from a prospectively maintained database, 1884 lymph node-negative breast cancer patients who underwent partial mastectomy with SLN mapping by a dual-tracer using patent blue dye (PBD) and radioisotope were retrospectively studied between January 2000 and July 2013. Patients with tumors <3 cm and with >1 node detected by one of the two techniques (N = 1024) were included in this real-life cross-sectional study. Among the 1024 patients, 274 had positive SLN detected by isotopic and/or PBD staining. Only 4 patients having no detectable radioactivity in the axilla had SLN identified only by PBD staining (blue-only) while 26 patients had SLN only identified by isotopic detection (hot-only) illustrating failure rates of 9.5% (26/274) and 1.5% (4/274), respectively. Among these four patients, two had negative lymphoscintigraphy. Therefore, the contribution of PBD to metastatic nodes identification was relevant for only 2/274 patients (0.8%). Three patients (0.3%) had an allergic reaction with PBD, and anaphylactic shock occurred in two cases (0.2%). The added-value of PBD to reduce the false-negative rate of SLN mapping is only limited to the rare cases in which no radioactivity is detectable in the axilla (<1%). When a radioisotope mapping agent is available, the use of PBD should be avoided, because it can induce anaphylaxis. Copyright © 2016 IJS Publishing Group Ltd. Published by Elsevier Ltd. All rights reserved.
Siesto, Gabriele; Romano, Fabrizio; Fiamengo, Barbara; Vitobello, Domenico
2016-01-01
Sentinel lymph node (SLN) mapping has emerged as the new frontier for the surgical staging of apparently early-stage cervical and endometrial cancer. Different colorimetric and radioactive tracers, alone and in combination, have been proposed with encouraging results. Fluorometric mapping using indocyanine green (ICG) appears to be a suitable and attractive alternative to provide reliable staging [1-4]. In this video, we present the technique of SLN mapping in 2 cases (1 endometrial and 1 cervical cancer, respectively) using ICG and the near-infrared technology provided by the newest Da Vinci Xi robotic system (Intuitive Surgical Inc., Sunnyvale, CA). Together we report the results of our preliminary experience on the first 20 cases performed. The new robotic Da Vinci Xi system was available at our institution since May 2015. Upon institutional review board/ethical committee approval, all consecutive patients with early-stage endometrial and cervical cancer who were judged suitable for robotic surgery have been enrolled for SLN mapping with ICG. We adopted the Memorial Sloan Kettering Cancer Center SLN algorithm; the tracer was delivered into the cervix in all cases. Four milliliters (1.25 mg/mL) of ICG was injected divided into the 3- and 9-o'clock positions of the cervix alone, with 1 mL deep into the stroma and 1 mL submucosally at the skin incision. Sentinel lymph nodes were examined with a protocol including both ultrastaging with immunohistochemistry [3] and 1-step nucleic acid amplification assay [5,6] under a parallel protocol of study. During the study period, 20 cases were managed; 14 and 6 patients had endometrial and cervical cancer, respectively. SLN was detected in all cases (20/20, 100%). Bilateral SLNs were detected in 17 of 20 (85.0%) cases. Based on preoperative and intraoperative findings, 13 (65.0%) patients received systematic pelvic lymphadenectomy after SLN mapping. Three (15.0%) patients had microscopic nodal metastases on SLN. No patients had positive regional nodes other than SLN. No perioperative complications were recorded. SLN mapping has been acknowledged by the National Comprehensive Cancer Network guidelines as a viable option for the management of selected uterine malignancies [7,8]. Currently, the near-infrared technology built in the Da Vinci Xi system provides an enhanced real-time imaging system that improves the advantages given by ICG. Together with our experience, these conditions indicate that SLN mapping is an effective and safe procedure with high overall detection and low false-negative rates. Copyright © 2016 AAGL. Published by Elsevier Inc. All rights reserved.
Tartaglione, G; Potenza, C; Caggiati, A; Maggiore, M; Gabrielli, F; Migliano, E; Pagan, M; Concolino, F; Ruatti, P
2002-01-01
The aim of our study was to evaluate the role of scintigraphy in lymphatic mapping and in the identification of the sentinel lymph node (SLN) in patients with head and neck cancer. Between September 1999 and February 2001 we enrolled 22 consecutive patients with cancer in the head and neck region: five squamous cell carcinomas, one Merkel cell tumor of the cheek, and 16 malignant melanomas. Lymphoscintigraphy was performed three hours before surgery after injection of 30-50 MBq of 99mTc -Nanocoll in 0.3 mL; the dose was fractionated by injecting the radiotracer at two points around the lesion. Static acquisition (anterior and/or lateral views, 512 x 512 matrix, 5 mins pre-set time) was started immediately after the injections so as to visualize the pathways of lymphatic drainage. The skin projection of the SLN was marked with ink. Intraoperative SLN detection was performed with perilesional injection of patent blue. SLNs were found with lymphoscintigraphy in all patients. Thirty-three SLNs were identified: one occipital node, three nodes at the base of the tongue, 10 superficial lateral nodes (external jugular), five submandibular nodes, five submental nodes, three mastoid nodes and six supraclavicular nodes. Biopsy was performed in 21/22 patients. In 20/22 patients the first lymph nodes were visualized in the proximal cranial regions (retroauricular, jugular and submandibular) at five minutes post injection. The SLN positivity rate was 13.6% (three patients). All patients with tumor-positive SLNs were submitted to radical dissection. Poor concordance in the detection of sentinel nodes was observed with patent blue. The flow of nanocolloid in the lymph vessels of the head is rapid. In our experience immediate scintigraphic imaging was essential to visualize the pathways of lymphatic drainage and the first SLN. Radioguided SLN biopsy is therefore recommended within three hours. Injection of patent blue is inadvisable because of the poor concordance with lymphoscintigraphy and the risk of permanent tattooing of the face.
Sentinel lymph node navigation surgery for gastric cancer: Does it really benefit the patient?
Tani, Tohru; Sonoda, Hiromichi; Tani, Masaji
2016-03-14
Sentinel lymph node (SLN) navigation surgery is accepted as a standard treatment procedure for malignant melanoma and breast cancer. However, the benefit of reduced lymphadenectomy based on SLN examination remains unclear in cases of gastric cancer. Here, we review previous studies to determine whether SLN navigation surgery is beneficial for gastric cancer patients. Recently, a large-scale prospective study from the Japanese Society of Sentinel Node Navigation Surgery reported that the endoscopic dual tracer method, using a dye and radioisotope for SLN biopsy, was safe and effective when applied to cases of superficial and relatively small gastric cancers. SLN mapping with SLN basin dissection was preferred for early gastric cancer since it is minimally invasive. However, previous studies reported that limited gastrectomy and lymphadenectomy may not improve the patient's postoperative quality of life (QOL). As a result, the benefit of SLN navigation surgery for gastric cancer patients, in terms of their QOL, is limited. Thus, endoscopic and laparoscopic limited gastrectomy combined with SLN navigation surgery has the potential to become the standard minimally invasive surgery in early gastric cancer.
Papadia, Andrea; Gasparri, Maria Luisa; Buda, Alessandro; Mueller, Michael D
2017-10-01
Sentinel lymph node (SLN) mapping in endometrial cancer (EMCA) is rapidly gaining acceptance in the clinical community. As compared to a full lymphadenectomy in every patient, to a selective lymphadenectomy after frozen section of uterus in selected patients with intrauterine risk factors or to a strategy in which a lymphadenectomy is always omitted, SLN mapping seems to be a reasonable and oncologically safe middle ground. Various protocols can be used when applying an SLN mapping. In this manuscript we review the characteristics, toxicity and clinical impact of technetium-99m radiocolloid (Tc-99m), of the blue dyes (methylene blue, isosulfan blue and patent blue) and of indocyanine green (ICG). ICG has an excellent toxicity profile, has higher overall and bilateral detection rates as compared to blue dyes and higher bilateral detection rates as compared to a combination of Tc-99m and blue dye. The detrimental effect of BMI on the detection rates is attenuated when ICG is used as a tracer. The ease of use of the ICG SLN mapping is perceived by the patients as a better quality of care delivered. Whenever possible, ICG should be favored over the other tracers for SLN mapping in EMCA patients.
Validation of the sentinel lymph node biopsy technique in head and neck cancers of the oral cavity.
Radkani, Pejman; Mesko, Thomas W; Paramo, Juan C
2013-12-01
The purpose of this study was to present our experience and validate the use of sentinel lymph node (SLN) mapping in patients with head and neck cancers. A retrospective review of a prospectively collected database of patients with a diagnosis of squamous cell carcinomas of the head and neck from 2008 to 2011 was done. The group consisted of a total of 20 patients. The first node(s) highlighted with blue, or identified as radioactive by Tc99-sulfur radioactive colloid, was (were) identified as the SLNs. In the first seven patients, formal modified neck dissection was performed. In the remaining 13 patients, only a SLN biopsy procedure was done. At least one SLN was identified in all 20 patients (100%). Only one patient (5%) had positive nodes. In this case, the SLN was also positive. In the remaining 19 cases, all lymph nodes were negative. After an average of 24 months of follow-up, there have been three local recurrences (15%) but no evidence of distant metastatic disease. SLN mapping in head and neck cancers is a feasible technique with a high identification rate and a low false-negative rate. Although the detection rate of regional metastatic disease compares favorably with published data as well as the disease-free and overall survival, further studies are warranted before considering this technique to be the "gold standard" in patients with oral squamous cell carcinoma and a negative neck by clinical examination and imaging studies.
Buda, Alessandro; Papadia, Andrea; Zapardiel, Ignacio; Vizza, Enrico; Ghezzi, Fabio; De Ponti, Elena; Lissoni, Andrea Alberto; Imboden, Sara; Diestro, Maria Dolores; Verri, Debora; Gasparri, Maria Luisa; Bussi, Beatrice; Di Martino, Giampaolo; de la Noval, Begoña Diaz; Mueller, Michael; Crivellaro, Cinzia
2016-09-01
The credibility of sentinel lymph node (SLN) mapping is becoming increasingly more established in cervical cancer. We aimed to assess the sensitivity of SLN biopsy in terms of detection rate and bilateral mapping in women with cervical cancer by comparing technetium-99 radiocolloid (Tc-99(m)) and blue dye (BD) versus fluorescence mapping with indocyanine green (ICG). Data of patients with cervical cancer stage 1A2 to 1B1 from 5 European institutions were retrospectively reviewed. All centers used a laparoscopic approach with the same intracervical dye injection. Detection rate and bilateral mapping of ICG were compared, respectively, with results obtained by standard Tc-99(m) with BD. Overall, 76 (53 %) of 144 of women underwent preoperative SLN mapping with radiotracer and intraoperative BD, whereas 68 of (47 %) 144 patients underwent mapping using intraoperative ICG. The detection rate of SLN mapping was 96 % and 100 % for Tc-99(m) with BD and ICG, respectively. Bilateral mapping was achieved in 98.5 % for ICG and 76.3 % for Tc-99(m) with BD; this difference was statistically significant (p < 0.0001). The fluorescence SLN mapping with ICG achieved a significantly higher detection rate and bilateral mapping compared to standard radiocolloid and BD technique in women with early stage cervical cancer. Nodal staging with an intracervical injection of ICG is accurate, safe, and reproducible in patients with cervical cancer. Before replacing lymphadenectomy completely, the additional value of fluorescence SLN mapping on both perioperative morbidity and survival should be explored and confirmed by ongoing controlled trials.
Intraoperative analysis of sentinel lymph nodes by imprint cytology for cancer of the breast.
Shiver, Stephen A; Creager, Andrew J; Geisinger, Kim; Perrier, Nancy D; Shen, Perry; Levine, Edward A
2002-11-01
The utilization of lymphatic mapping techniques for breast carcinoma has made intraoperative evaluation of sentinel lymph nodes (SLN) attractive, because axillary lymph node dissection can be performed during the initial surgery if the SLN is positive. The optimal technique for rapid SLN assessment has not been determined. Both frozen sectioning and imprint cytology are used for rapid intraoperative SLN evaluation. A retrospective review of the intraoperative imprint cytology results of 133 SLN mapping procedures from 132 breast carcinoma patients was performed. SLN were evaluated intraoperatively by bisecting the lymph node and making imprints of each cut surface. Imprints were stained with hematoxylin and eosin (H&E) and Diff-Quik. Permanent sections were evaluated with up to four H&E stained levels and cytokeratin immunohistochemistry. Imprint cytology results were compared with final histologic results. Sensitivity and specificity of imprint cytology were 56% and 100%, respectively, producing a 100% positive predictive value and 88% negative predictive value. Imprint cytology was significantly more sensitive for macrometastasis than micrometastasis 87% versus 22% (P = 0.00007). Of 13 total false negatives, 11 were found to be due to sampling error and 2 due to errors in intraoperative interpretation. Both intraoperative interpretation errors involved a diagnosis of lobular breast carcinoma. The sensitivity and specificity of imprint cytology are similar to that of frozen section evaluation. Imprint cytology is therefore a viable alternative to frozen sectioning when intraoperative evaluation is required. If SLN micrometastasis is used to determine the need for further lymphadenectomy, more sensitive intraoperative methods will be needed to avoid a second operation.
Near infrared fluorescent chlorophyll nanoscale liposomes for sentinel lymph node mapping
Fan, Lina; Wu, Qiang; Chu, Maoquan
2012-01-01
Background Sentinel lymph node (SLN) mapping using in vivo near infrared fluorescence imaging has attracted great attention during the past few years. Here we report on the early use of poorly water-soluble chlorophyll with near infrared fluorescence extracted from the leaf of Chimonanthus salicifolius, for mouse axillary SLN mapping. Methods and results To improve the water solubility and SLN targeting of the chlorophyll, we encapsulated the chlorophyll in nanoscale liposomes. The liposome-coated chlorophyll nanocomposites obtained were spherical in shape and had an average diameter of 21.7 ± 6.0 nm. The nanocomposites dispersed well in water, and in aqueous suspension they exhibited brighter near infrared fluorescence than chlorophyll alone. After incubation of the nanocomposites with normal liver cells (QSG-7701) and macrophage cells (Ana-1) for no more than 48 hours, there was no obvious reduction in cell viability. When the nanocomposites were injected intradermally into the paw of a mouse, the axillary SLN was found to be strongly fluorescent and was easily visualized in real time without a requirement for surgery. The intensity of the near infrared fluorescence emitted by the SLN was obviously brighter than that emitted by the SLN of another mouse that had been intradermally injected with chlorophyll alone. Conclusion Our data show that the liposome-coated chlorophyll nanocomposites could have great potential for clinical SLN mapping due to their lack of toxicity, bright near infrared fluorescence, and small diameter. PMID:22787402
Abu-Rustum, Nadeem R.; Khoury-Collado, Fady; Pandit-Taskar, Neeta; Soslow, Robert A.; Dao, Fanny; Sonoda, Yukio; Levine, Douglas A.; Brown, Carol L.; Chi, Dennis S.; Barakat, Richard R.; Gemignani, Mary L.
2014-01-01
Objective To describe the accuracy of SLN mapping in patients with a preoperative diagnosis of grade 1 endometrial cancer. Methods A prospective, non-randomized study of women with a preoperative diagnosis of endometrial cancer and clinical stage I disease was conducted. A subset analysis of patients with a preoperative diagnosis of grade 1 endometrial endometrioid cancer was performed. All patients had preoperative lymphoscintigraphy with Tc99m on the day of or day before surgery followed by an intraoperative injection of 2cc of isosulfan or methylene blue dye deep into the cervix or both cervix and fundus. All patients underwent hysterectomy, bilateral salpingo-oophorectomy, and regional nodal dissection. Hot and/or blue nodes were labeled as SLNs and sent for histopathological analysis. Results Forty-two patients with a preoperative diagnosis of grade 1 endometrial carcinoma treated from 3/06–8/08 were identified. Twenty-five(60%) had laparoscopic surgery; 17(40%) were treated by laparotomy. Preoperative lymphoscintigraphy visualized SLNs in 30 patients(71%); intraoperative localization of the SLN was possible in 36(86%). A median of 3 SLNs(range, 1–14) and 14.5 non-SLNs(range, 4–55) were examined. In all, 4/36(11%) had positive SLNs—3 seen on H&E and 1 as cytokeratin-positive cells on IHC. All node-positive cases were picked up by the SLN; there were no false-negative cases. The sensitivity of the SLN procedure in the 36 patients who had an SLN identified was 100%. Conclusion Sentinel lymph node mapping using a cervical injection with combined Tc and blue dye is feasible and accurate in patients with grade 1 endometrial cancer and may be a reasonable option for this select group of patients. Regional lymphadenectomy remains the gold standard in many practices, particularly for the approximately 15% of cases with failed SLN mapping. PMID:19232699
Currie, A C; Brigic, A; Thomas-Gibson, S; Suzuki, N; Moorghen, M; Jenkins, J T; Faiz, O D; Kennedy, R H
2017-11-01
Previous attempts at sentinel lymph node (SLN) mapping in colon cancer have been compromised by ineffective tracers and the inclusion of advanced disease. This study evaluated the feasibility of fluorescence detection of SLNs with indocyanine green (ICG) for lymphatic mapping in T1/T2 clinically staged colonic malignancy. Consecutive patients with clinical T1/T2 stage colon cancer underwent endoscopic peritumoral submucosal injection of indocyanine green (ICG) for fluorescence detection of SLN using a near-infrared (NIR) camera. All patients underwent laparoscopic complete mesocolic excision surgery. Detection rate and sensitivity of the NIR-ICG technique were the study endpoints. Thirty patients mean age = 68 years [range = 38-80], mean BMI = 26.2 (IQR = 24.7-28.6) were studied. Mesocolic sentinel nodes (median = 3/patient) were detected by fluorescence within the standard resection field in 27/30 patients. Overall, ten patients had lymph node metastases, with one of these patients having a failed SLN procedure. Of the 27 patients with completed SLN mapping, nine patients had histologically positive lymph nodes containing malignancy. 3/9 had positive SLNs with 6 false negatives. In five of these false negative patients, tumours were larger than 35 mm with four also being T3/T4. ICG mapping with NIR fluorescence allowed mesenteric detection of SLNs in clinical T1/T2 stage colonic cancer. CLINICALTRIALS.GOV: ID: NCT01662752. Copyright © 2017 Elsevier Ltd, BASO ~ The Association for Cancer Surgery, and the European Society of Surgical Oncology. All rights reserved.
Intraoperative imprint cytology for evaluation of sentinel lymph nodes from Merkel cell carcinoma.
Wong, S Lindsey; Young, Yorke D; Geisinger, Kim R; Shen, Perry; Stewart, John H; Sangueza, Omar; Pichardo-Geisinger, Rita; Levine, Edward A
2009-07-01
Merkel cell carcinoma (MCC) is a rare, aggressive cutaneous malignancy. Intraoperative imprint cytology (IIC) can potentially avoid second operations for completion lymphadenectomy when nodal metastases are found during nodal staging with sentinel lymph node biopsy (SLN). This represents the first series of IIC for MCC we are aware of and our initial experience. Patients with biopsy-proven MCC underwent SLN (at the time of wide excision) using a double indicator technique with 99technetium sulfur colloid and isosulfan blue. SLN were identified and bisected and touch imprints of each half were made. One half was air-dried and stained with Diff-Quick and the other was fixed with 95 per cent alcohol and stained with hematoxylin and eosin (H&E). Paraffin-embedded sections were examined by H&E. Eighteen patients underwent successful SLN mapping procedures. IIC was negative in 84.2 per cent (16) cases. Three false-negatives occurred with IIC, but there were no false-positives, making the sensitivity 33 per cent and the specificity 100 per cent. Two of four patients with positive pathology-confirmed SLN also had positive IIC. SLN mapping has usefulness in patients with MCC. IIC is feasible and accurate in evaluating the SLN. IIC is a practical diagnostic tool when intraoperative analysis of SLN biopsy is desired for MCC.
Technical details of sentinel lymph node mapping in colorectal cancer and its impact on staging.
Saha, S; Wiese, D; Badin, J; Beutler, T; Nora, D; Ganatra, B K; Desai, D; Kaushal, S; Nagaraju, M; Arora, M; Singh, T
2000-03-01
Sentinel lymph node (SLN) mapping for melanoma and breast cancer has greatly enhanced the identification of micrometastases in many patients, thereby upstaging a subset of these patients. The purpose of this study was to see if SLN mapping technique could be used to identify SLNs in colorectal cancer and to assess its impact on pathological staging and treatment. At the time of surgery, 1 ml of Lymphazurin 1% was injected subserosally around the tumor without injecting into the lumen. The first to fourth blue nodes identified were considered the SLNs, which have the highest probability to contain metastases. A standard oncological resection of the bowel was then performed. Multilevel microsections of the SLNs, including a detailed pathological examination of the entire specimen, was performed. SLN was successfully identified in 85 (98.8%) of 86 patients. In 85 patients, there were 1,367 (16 per patient) lymph nodes examined, of which 140 (1.6 per patient) were identified as SLNs. In 53 (95%) of 56, of whom the SLNs were without metastases (negative), all other non-SLNs also were negative. In 29 (34% of 85) patients, SLNs were positive for metastases; in 14 of the 29 patients, other non-SLNs also were positive in addition to the SLNs. In the other 15 of the 29 patients (18% of 85 patients), SLNs were the only site of metastases, and all other non-SLNs were negative. In 7 patients (8.2% of 85 patients), micrometastases were identified only in 1 or 2 of the 10 sections of a single SLN. In five of seven patients, such micrometastases were detected by hematoxylin and eosin staining and immunohistochemistry; in the other two patients, it was detected only by immunohistochemistry. In patients with negative SLNs, the rate of occurrence of micrometastases in non-SLNs was 5 (0.4%) of 1,184 lymph nodes. SLN mapping can be performed easily in colorectal cancer patients, with an accuracy of more than 95%. The identification of submicroscopic lymph node metastases by this technique may have upstaged these patients (18%) from stage I/II to stage III disease, who may then benefit from further adjuvant chemotherapy.
Near-infrared fluorescence sentinel lymph node mapping in breast cancer: a multicenter experience
Verbeek, Floris P.R.; Troyan, Susan L.; Mieog, J. Sven D.; Liefers, Gerrit-Jan; Moffitt, Lorissa A.; Rosenberg, Mireille; Hirshfield-Bartek, Judith; Gioux, Sylvain; van de Velde, Cornelis J.H.; Vahrmeijer, Alexander L.; Frangioni, John V.
2014-01-01
NIR fluorescence imaging using indocyanine green (ICG) has the potential to improve the SLN procedure by facilitating percutaneous and intraoperative identification of lymphatic channels and SLNs. Previous studies suggested that a dose of 0.62 mg (1.6 ml of 0.5 mM) ICG is optimal for SLN mapping in breast cancer. The aim of this study was to evaluate the diagnostic accuracy of near-infrared (NIR) fluorescence for sentinel lymph node (SLN) mapping in breast cancer patients when used in conjunction with conventional techniques. Study subjects were 95 breast cancer patients planning to undergo SLN procedure at either the Dana-Farber/Harvard Cancer Center (Boston, MA, USA) or the Leiden University Medical Center (Leiden, the Netherlands) between July 2010 and January 2013. Subjects underwent the standard-of-care SLN procedure at each institution using 99Technetium-colloid in all subjects and patent blue in 27 (28%) of the subjects. NIR fluorescence-guided SLN detection was performed using the Mini-FLARE imaging system. SLN identification was successful in 94 of 95 subjects (99%) using NIR fluorescence imaging or a combination of both NIR fluorescence imaging and radioactive guidance. In 2 of 95 subjects, radioactive guidance was necessary for initial in vivo identification of SLNs. In 1 of 95 subjects, NIR fluorescence was necessary for initial in vivo identification of SLNs. A total of 177 SLNs (mean = 1.9, range = 1–5) were resected: 100% NIR fluorescent, 88% radioactive, and 78% (of 40 nodes) blue. In 2 of 95 subjects (2.1%), SLNs containing macrometastases were found only by NIR fluorescence, and in 1 patient this led to upstaging to N1. This study demonstrates the safe and accurate application of NIR fluorescence imaging for the identification of SLNs in breast cancer patients, but calls into question what technique should be used as the gold standard in future studies. PMID:24337507
Sentinel Lymph Node Biopsy for Cutaneous Head and Neck Melanoma: Mapping the Parotid Gland.
Picon, Antonio I; Coit, Daniel G; Shaha, Ashok R; Brady, Mary S; Boyle, Jay O; Singh, Bhuvanesh B; Wong, Richard J; Busam, Klaus J; Shah, Jatin P; Kraus, Dennis H
2016-12-01
Sentinel lymph node biopsy (SLNB) for primary cutaneous head and neck melanoma (CHNM) has been shown to be successful and is the current standard of care for intermediate-thickness melanoma. We evaluated our experience with CHNM associated with SLNB mapping to the region of the parotid gland. Retrospective review of a prospectively collected melanoma database identified 1014 CHNMs. Two-hundred twenty-three patients underwent SLNB, and 72 (32%) had mapping in the region of the parotid gland between May 1995 and June 2003. The mean number of SLNs per patient was 2.5. A sentinel lymph node (SLN) was successfully identified in 94% of patients, and in 12%, the SLN was positive for metastatic disease. Biopsy of intraparotid SLNs was performed in 51.4% and of periparotid SLNs in 26.4%, and a superficial parotidectomy was performed in 22.2%. Ten patients were found to have lymph nodes in the parotid region with metastatic disease (eight identified by SLNB), and two (20%) patients developed intraparotid lymph node recurrence in the setting of a negative SLNB. Same-basin recurrence in SLN-negative patients was 3.3% with a median follow-up of 26 months. Facial nerve dysfunction was identified in seven (10%) patients. Facial nerve function returned to preoperative status in all patients. SLNB for patients with primary CHNM mapping to the parotid gland can be performed with a high degree of accuracy and a low morbidity consisting of temporary facial nerve paresis.
Liu, Christina Y; Elias, Kevin M; Howitt, Brooke E; Lee, Larissa J; Feltmate, Colleen M
2017-05-01
To examine the effects of universal sentinel lymph node mapping on the use of nodal staging in endometrial adenocarcinoma. Two approaches to laparoscopic staging for endometrial adenocarcinoma were compared using a before and after study design. The before cohort underwent selective lymphadenectomy from January 1, 2014-October 1, 2015 while the after cohort underwent universal sentinel lymph node (SLN) mapping from October 2, 2015-September 29, 2016. The before cohort comprised 215 patients and the after cohort 166 patients. In women undergoing SLN mapping, a sentinel node was identified at least unilaterally in 146/153 cases (95.4%), and bilaterally in 114/153 (74.5%) of cases. Pelvic nodes were removed in 35.8% of the before cohort versus 92.2% of the after cohort (p<0.0001) with more nodal evaluation among both low risk (9.6% vs. 91%, p<0.0001) and high risk cases (66% vs. 94%, p<0.0001). While the proportion of low risk cases diagnosed with nodal involvement did not significantly change (0.9% to 3.1%, p=0.32), there was a trend toward more diagnoses of nodal involvement in high risk cases (5% to 13.2%, p=0.06). Mean number of pelvic lymph nodes removed (15 vs. 4, p<0.0001), mean operative time (181min vs. 137min, p<0.0001), estimated blood loss (80ml vs. 56ml, p=0.004), and rate of post-operative complications (13% vs. 5.2%, p=0.04) all decreased after the adoption of SLN dissection. Universal sentinel lymph node dissection for laparoscopic endometrial cancer staging reduces heterogeneity in surgeon staging practice, increases nodal detection, and lowers post-operative complications. Copyright © 2017 Elsevier Inc. All rights reserved.
Buda, Alessandro; Passoni, Paolo; Corrado, Giacomo; Bussi, Beatrice; Cutillo, Giuseppe; Magni, Sonia; Vizza, Enrico
2017-01-01
Sentinel lymph node (SLN) mapping has increased its feasibility in both early-stage cervical and endometrial cancer. There are few SLN studies regarding the ovary because of the risk of tumor dissemination and perhaps because the ovary represents an inconvenient site for injection. In this preliminary study, we have shown the feasibility of SLN mapping of the ovary with indocyanine green during laparoscopic retroperitoneal aortic surgical staging. The 10 women who were included in this study underwent aortic with pelvic laparoscopic staging, which included SLN biopsy, extrafascial total hysterectomy, and bilateral salpingo-oophorectomy in case of an ovarian tumor. The fluorescent dye was injected on the dorsal and ventral side of the proper ovarian ligament and the suspensory ligament, close to the ovary and just underneath the peritoneum. In all cases except 1, SLNs were detected soon after the injection in the aortic compartment and in 3 cases also in the common iliac region. Only 1 intraoperative complication occurred: a superficial lesion of the vena cava that was recovered with a laparoscopic suture. Laparoscopic ovarian SLN mapping performed by means of an injection of indocyanine green fluorescent tracer in the ovarian ligaments seems feasible and promising. Further investigation are encouraged and necessary to evaluate the possible applications of this new technique for staging patients with early-stage ovarian cancer. Copyright © 2016 AAGL. Published by Elsevier Inc. All rights reserved.
Takada, Masahiro; Takeuchi, Megumi; Suzuki, Eiji; Sato, Fumiaki; Matsumoto, Yoshiaki; Torii, Masae; Kawaguchi-Sakita, Nobuko; Nishino, Hiroto; Seo, Satoru; Hatano, Etsuro; Toi, Masakazu
2018-05-09
Inability to visualize indocyanine green fluorescence images in the surgical field limits the application of current near-infrared fluorescence imaging (NIR) systems for real-time navigation during sentinel lymph node (SLN) biopsy in breast cancer patients. The aim of this study was to evaluate the usefulness of the Medical Imaging Projection System (MIPS), which uses active projection mapping, for SLN biopsy. A total of 56 patients (59 procedures) underwent SLN biopsy using the MIPS between March 2016 and November 2017. After SLN biopsy using the MIPS, residual SLNs were removed using a conventional NIR camera and/or radioisotope method. The primary endpoint of this study was identification rate of SLNs using the MIPS. In all procedures, at least one SLN was detected by the MIPS, giving an SLN identification rate of 100% [95% confidence interval (CI) 94-100%]. SLN biopsy was successfully performed without operating lights in all procedures. In total, 3 positive SLNs were excised using MIPS, but were not included in the additional SLNs excised by other methods. The median number of SLNs excised using the MIPS was 3 (range 1-7). Of procedures performed after preoperative systemic therapy, the median number of SLNs excised using the MIPS was 3 (range 2-6). The MIPS is effective in detecting SLNs in patients with breast cancer, providing continuous and accurate projection of fluorescence signals in the surgical field, without need for operating lights, and could be useful in real-time navigation surgery for SLN biopsy.
Niikura, Hitoshi; Okamura, Chikako; Akahira, Junichi; Takano, Tadao; Ito, Kiyoshi; Okamura, Kunihiro; Yaegashi, Nobuo
2004-08-01
The purpose of this study was to examine sentinel lymph node (SLN) detection in patients with early stage cervical cancer using (99m)Tc phytate and patent blue dye and to compare our method with published findings utilizing other radioisotopic tracers. A total of 20 consecutive patients with cervical cancer scheduled for radical hysterectomy and total pelvic lymphadenectomy at our hospital underwent SLN detection study. The day before surgery, lymphoscintigraphy was performed with injection of 99m-technetium ((99m)Tc)-labeled phytate into the uterine cervix. At surgery, patients underwent lymphatic mapping with a gamma-detecting probe and patent blue injected into the same points as the phytate solution. At least one positive node was detected in 18 patients (90%). A total of 46 sentinel nodes were detected (mean, 2.3; range, 1-5). Most sentinel nodes were in one of the following sites: external iliac (21 nodes), obturator (15 nodes), and parametrial (7 nodes). Eleven (24%) sentinel nodes were detected only through radioactivity and two (4%) were detected only with blue dye. The sensitivity, specificity, and negative predictive value for SLN detection were all 100%. Nine published studies involving 295 patients had a summarized detection rate of 85%. Summarized sensitivity, specificity, and negative predictive value were 93%, 100%, and 99%, respectively. Combination of (99m)Tc phytate and patent blue is effective in SLN detection in early stage cervical cancer.
Tumor differentiation as related to sentinel lymph node status in gastric cancer
Lavy, Ron; Kapiev, Andronik; Hershkovitz, Yehuda; Poluksht, Natan; Rabin, Igor; Chikman, Bar; Shapira, Zahar; Wasserman, Ilan; Sandbank, Judith; Halevy, Ariel
2014-01-01
AIM: To investigate the influence of tumor grade on sentinel lymph node (SLN) status in patients with gastric cancer (GC). METHODS: We retrospectively studied 71 patients with GC who underwent SLN mapping during gastric surgery to evaluate the relationship between SLN status and tumor grade. RESULTS: Poorly differentiated tumors were detected in 50/71 patients, while the other 21 patients had moderately differentiated tumors. SLNs were identified in 58/71 patients (82%). In 41 of the 58 patients that were found to have stained nodes (70.7%), the tumor was of the poorly differentiated type (group I), while in the remaining patients with stained nodes 17/58 (29.3%), the tumor was of the moderately differentiated type (group II). Positive SLNs were found in 22/41 patients in group I (53.7%) and in 7/17 patients in group II (41.2%) (P = 0.325). The rate of positivity for the SLNs in the two groups (53.7% vs 41.2%) was not statistically significant (P = 0.514). CONCLUSION: Most of our patients were found to have poorly differentiated adenocarcinoma of the stomach and there was no correlation between tumor grade and SLN involvement. PMID:24627734
Molecular analysis of breast sentinel lymph nodes.
Blumencranz, Peter W; Pieretti, Maura; Allen, Kathleen G; Blumencranz, Lisa E
2011-07-01
Lymphatic mapping and sentinel lymph node (SLN) biopsy have become the standard of care for staging the axilla in patients with invasive breast cancer. Current histologic methods for SLN evaluation have limitations, including subjectivity, limited sensitivity, and lack of standardization. The discovery of molecular markers to detect metastases has been reported over the last 2 decades. The authors review the historical development of these markers and the clinical use of one of the molecular platforms in 478 patients at their institution. Controversies and future directions are discussed. Copyright © 2011 Elsevier Inc. All rights reserved.
Han, Chao; Yang, Ben; Zuo, Wen-Shu; Zheng, Gang; Yang, Li; Zheng, Mei-Zhu
2016-01-01
Objective The axillary reverse mapping (ARM) technique has recently been developed to prevent lymphedema by preserving the arm lymphatic drainage during sentinel lymph node biopsy (SLNB) or axillary lymph node dissection (ALND) procedures. The objective of this systematic review and meta-analysis was to evaluate the feasibility and oncological safety of ARM. Methods We searched Medline, Embase, Web of science, Scopus, and the Cochrane Library for relevant prospective studies. The identification rate of ARM nodes, the crossover rate of SLN-ARM nodes, the proportion of metastatic ARM nodes, and the incidence of complications were pooled into meta-analyses by the random-effects model. Results A total of 24 prospective studies were included into meta-analyses, of which 11 studies reported ARM during SLNB, and 18 studies reported ARM during SLNB. The overall identification rate of ARM nodes was 38.2% (95% CI 32.9%-43.8%) during SLNB and 82.8% (78.0%-86.6%) during ALND, respectively. The crossover rate of SLN-ARM nodes was 19.6% (95% CI 14.4%-26.1%). The metastatic rate of ARM nodes was 16.9% (95% CI 14.2%-20.1%). The pooled incidence of lymphedema was 4.1% (95% CI 2.9–5.9%) for patients undergoing ARM procedure. Conclusions The ARM procedure was feasible during ALND. Nevertheless, it was restricted by low identification rate of ARM nodes during SLNB. ARM was beneficial for preventing lymphedema. However, this technique should be performed with caution given the possibility of crossover SLN-ARM nodes and metastatic ARM nodes. ARM appeared to be unsuitable for patients with clinically positive breast cancer due to oncological safety concern. PMID:26919589
Moukarzel, Lea A; Sinno, Abdulrahman K; Fader, Amanda N; Tanner, Edward J
To compare operative times, surgical outcomes, and costs of robotic laparoendoscopic single-site (R-LESS) vs multiport robotic (MPR) total laparoscopic hysterectomy (TLH) with sentinel lymph node (SLN) mapping for low-risk endometrial cancer. Retrospective cohort study (Canadian Task Force classification II-2). Academic university hospital. Patients with a biopsy-proven diagnosis of complex atypical hyperplasia (CAH) or low-grade (1 or 2) endometrial cancer with body mass index <30 kg/m 2 and undergoing robotic TLH and SLN mapping between 2012 and 2016 were included. Surgical outcomes and cost data were collected retrospectively and analyzed based on the surgical approach with R-LESS vs MPR assistance. Twenty-seven patients who met the inclusion criteria were identified, including 14 patients who underwent R-LESS TLH with SLN mapping and 13 patients who underwent MPR TLH with SLN mapping. Median uterine weight was comparable in the 2 cohorts (111.3 g vs 83.8 g; p = .33). Operative and console times were equivalent with the R-LESS and MPR approaches (median, 175 minutes vs 184 minutes, p = .61 and 136 vs 140 minutes, p = .12, respectively). Median estimated blood loss was 50 mL in both cohorts. Successful bilateral SLN mapping occurred in 85.7% of the R-LESS procedures and 76.9% of MPR procedures. No intraoperative or 30-day complications were encountered, and all patients were discharged within 23 hours of surgery. MPR was associated with additional disposable instrument and drape costs of $460 to $660 compared with R-LESS, depending on the surgeon's instrument selection. Average total hospital charges were lower for R-LESS procedures ($13,410 vs $15,952; p < .05). In highly selected patients with CAH or low-grade endometrial cancer undergoing TLH and SLN mapping, R-LESS appears to result in equivalent perioperative outcomes as a MPR approach while offering a more cost-effective option. Further research is needed to determine the benefits of R-LESS procedures in the gynecologic oncology setting. Copyright © 2017 AAGL. Published by Elsevier Inc. All rights reserved.
Radenkovic, Dina; Kobayashi, Hisataka; Remsey-Semmelweis, Ernö; Seifalian, Alexander M
2016-08-01
Breast cancer is the most common cancer in the world. Sentinel lymph node (SLN) biopsy is used for staging of axillary lymph nodes. Organic dyes and radiocolloid are currently used for SLN mapping, but expose patients to ionizing radiation, are unstable during surgery and cause local tissue damage. Quantum dots (QD) could be used for SLN mapping without the need for biopsy. Surgical resection of the primary tumor is the optimal treatment for early-diagnosed breast cancer, but due to difficulties in defining tumor margins, cancer cells often remain leading to reoccurrences. Functionalized QD could be used for image-guided tumor resection to allow visualization of cancer cells. Near Infrared QD are photostable and have improved deep tissue penetration. Slow elimination of QD raises concerns of potential accumulation. Nevertheless, promising findings with cadmium-free QD in recent in vivo studies and first in-human trial suggest huge potential for cancer diagnostic and therapy. Copyright © 2016 Elsevier Inc. All rights reserved.
Sentinel lymph node mapping in endometrial cancer: a systematic review and meta-analysis.
Lin, Hefeng; Ding, Zheyuan; Kota, Vishnu Goutham; Zhang, Xiaoming; Zhou, Jianwei
2017-07-11
Endometrial cancer is the most frequent tumor in the female reproductive system, while the sentinel lymph node (SLN) mapping for diagnostic efficacy of endometrial cancer is still controversial. This meta-analysis was conducted to evaluate the diagnostic value of SLN in the assessment of lymph nodal involvement in endometrial cancer. Forty-four studies including 2,236 cases were identified. The pooled overall detection rate was 83% (95% CI: 80-86%). The pooled sensitivity was 91% (95% CI: 87-95%). The bilateral pelvic node detection rate was 56% (95% CI: 48-64%). Use of indocyanine green (ICG) increased the overall detection rate to 93% (95% CI: 89-96%) and robotic-assisted surgery also increased the overall detection rate to 86% (95% CI: 79-93%). In summary, our meta-analysis provides strong evidence that sentinel node mapping is an accurate and feasible method that performs well diagnostically for the assessment of lymph nodal involvement in endometrial cancer. Cervical injection, robot-assisted surgery, as well as using ICG, optimized the sensitivity and detection rate of the technique. Sentinel lymph mapping may potentially leading to a greater utilization by gynecologic surgeons in the future.
NASA Astrophysics Data System (ADS)
Erpelding, Todd N.; Kim, Chulhong; Pramanik, Manojit; Guo, Zijian; Dean, John; Jankovic, Ladislav; Maslov, Konstantin; Wang, Lihong V.
2010-02-01
Sentinel lymph node biopsy (SLNB) has become the standard method for axillary staging in breast cancer patients, relying on invasive identification of sentinel lymph nodes (SLNs) following injection of blue dye and radioactive tracers. While SLNB achieves a low false negative rate (5-10%), it is an invasive procedure requiring ionizing radiation. As an alternative to SLNB, ultrasound-guided fine needle aspiration biopsy has been tested clinically. However, ultrasound alone is unable to accurately identify which lymph nodes are sentinel. Therefore, a non-ionizing and noninvasive detection method for accurate SLN mapping is needed. In this study, we successfully imaged methylene blue dye accumulation in vivo in rat axillary lymph nodes using a Phillips iU22 ultrasound imaging system adapted for photoacoustic imaging with an Nd:YAG pumped, tunable dye laser. Photoacoustic images of rat SLNs clearly identify methylene blue dye accumulation within minutes following intradermal dye injection and co-registered photoacoustic/ultrasound images illustrate lymph node position relative to surrounding anatomy. To investigate clinical translation, the imaging depth was extended up to 2.5 cm by adding chicken breast tissue on top of the rat skin surface. These results raise confidence that photoacoustic imaging can be used clinically for accurate, noninvasive SLN mapping.
Buda, Alessandro; Crivellaro, Cinzia; Elisei, Federica; Di Martino, Giampaolo; Guerra, Luca; De Ponti, Elena; Cuzzocrea, Marco; Giuliani, Daniela; Sina, Federica; Magni, Sonia; Landoni, Claudio; Milani, Rodolfo
2016-07-01
To compare the detection rate (DR) and bilateral optimal mapping (OM) of sentinel lymph nodes (SLNs) in women with endometrial and cervical cancer using indocyanine green (ICG) versus the standard technetium-99m radiocolloid ((99m)Tc) radiotracer plus methylene or isosulfan blue, or blue dye alone. From October 2010 to May 2015, 163 women with stage I endometrial or cervical cancer (118 endometrial and 45 cervical cancer) underwent SLN mapping with (99m)Tc with blue dye, blue dye alone, or ICG. DR and bilateral OM of ICG were compared respectively with the results obtained using the standard (99m)Tc radiotracer with blue dye, or blue dye alone. SLN mapping with (99m)Tc radiotracer with blue dye was performed on 77 of 163 women, 38 with blue dye only and 48 with ICG. The overall DR of SLN mapping was 97, 89, and 100 % for (99m)Tc with blue dye, blue dye alone, and ICG, respectively. The bilateral OM rate for ICG was 85 %-significantly higher than the 58 % obtained with (99m)Tc with blue dye (p = 0.003) and the 54 % for blue dye (p = 0.001). Thirty-one women (19 %) had positive SLNs. Sensitivity and negative predictive value of SLN were 100 % for all techniques. SLNs mapping using ICG demonstrated higher DR compared to other modalities. In addition, ICG was significantly superior to (99m)Tc with blue dye in terms of bilateral OM in women with early stage endometrial and cervical cancer. The higher number of bilateral OM may consequently reduce the overall number of complete lymphadenectomies, reducing the duration and additional costs of surgical treatment.
Devaja, Omer; Mehra, Gautam; Coutts, Michael; Montalto, Stephen Attard; Donaldson, John; Kodampur, Mallikarjun; Papadopoulos, Andreas John
2012-07-01
To establish the accuracy of sentinel lymph node (SLN) detection in early cervical cancer. Sentinel lymph node detection was performed prospectively over a 6-year period in 86 women undergoing surgery for cervical carcinoma by the combined method (Tc-99m and methylene blue dye). Further ultrastaging was performed on a subgroup of 26 patients who had benign SLNs on initial routine histological examination. The SLN was detected in 84 (97.7%) of 86 women by the combined method. Blue dye uptake was not seen in 8 women (90.7%). Sentinel lymph nodes were detected bilaterally in 63 women (73.3%), and the external iliac region was the most common anatomic location (48.8%). The median SLN count was 3 nodes (range, 1-7). Of the 84 women with sentinel node detection, 65 also underwent bilateral pelvic lymph node dissection, and in none of these cases was a benign SLN associated with a malignant non-SLN (100% negative predictive value). The median non-SLN count for all patients was 19 nodes (range, 8-35). Eighteen patients underwent removal of the SLN without bilateral pelvic lymph node dissection. Nine women (10.5%) had positive lymph nodes on final histology. One patient had bulky pelvic nodes on preoperative imaging and underwent removal of the negative bulky malignant lymph nodes and a benign SLN on the contralateral side. This latter case confirms the unreliability of the SLN method with bulky nodes. The remaining 8 patients had positive SLNs with negative nonsentinel lymph nodes. Fifty-nine SLNs from 26 patients, which were benign on initial routine histology, underwent ultrastaging, but no further disease was identified. Four patients (5%) relapsed after a median follow-up of 28 months (range, 8-80 months). Sentinel lymph node detection is an accurate and safe method in the assessment of nodal status in early cervical carcinoma.
Lymphatic mapping for gastric adenocarcinoma.
Hundley, Jon C; Shen, Perry; Shiver, Stephen A; Geisinger, Kim R; Levine, Edward A
2002-11-01
The role of lymphadenectomy for gastric carcinoma has been debated for decades. Lymphatic mapping has revolutionized the treatment of melanoma and breast cancer. However, its potential utility in guiding lymphadenectomy for gastric carcinoma is unknown. Therefore we initiated a trial to investigate lymphatic mapping for gastric carcinoma at Wake Forest University Baptist Medical Center. Lymphatic mapping for gastric carcinoma was attempted in 14 cases of gastric carcinoma. Mapping was performed by perilesional injection of isosulfan blue and the first node in the draining basin was harvested and sent fresh to pathology. Sentinel lymph nodes (SLNs) were evaluated by hematoxylin and eosin (H&E) staining. Immunohistochemical analysis was performed on all SLNs that were found to be negative on initial histologic studies. Radical gastrectomy with celiac node dissection was performed in all cases. SLNs were identified in 14 cases. In one case the technique was abandoned because of bulk nodal disease. The average number of SLNs found in each case was 2.8 with a range of one to five. Eight of 14 patients were found to have SLNs positive for metastatic carcinoma. In seven of these patients pathologic analysis of the final resection specimen confirmed the presence of nodal disease. In one case carcinoma was found in a SLN on touch preparation and no nodal disease was noted in the resection specimen. Immunohistochemical studies performed on SLNs found to be negative on initial H&E histologic analysis failed to reveal the presence of carcinoma. The overall sensitivity and specificity were found to be 72.7 and 75 per cent, respectively. Lymphatic mapping is technically possible in the setting of gastric carcinoma and SLNs can be successfully identified in the majority of cases. Upstaging occurred in one case which may have ramifications for adjuvant therapy. SLN positivity accurately predicts the presence of additional nodal disease beyond the SLN in the final resection specimen (positive predictive value 89%). However, SLN negativity does not definitively prove that the remaining nodal basin is free of disease (negative predictive value 50%). Lymphatic mapping for gastric carcinoma is a promising technique worthy of further investigation.
Hoogendam, Jacob P; Zweemer, Ronald P; Hobbelink, Monique G G; van den Bosch, Maurice A A J; Verheijen, René H M; Veldhuis, Wouter B
2016-04-01
We aimed to explore the accuracy of (99m)Tc SPECT/MRI fusion for the selective assessment of nonenlarged sentinel lymph nodes (SLNs) for diagnosing metastases in early-stage cervical cancer patients. We consecutively included stage IA1-IIB1 cervical cancer patients who presented to our tertiary referral center between March 2011 and February 2015. Patients with enlarged lymph nodes (short axis ≥ 10 mm) on MRI were excluded. Patients underwent an SLN procedure with preoperative (99m)Tc-nanocolloid SPECT/CT-based SLN mapping. When fused datasets of the SPECT and MR images were created, SLNs could be identified on the MR image with accurate correlation to the histologic result of each individual SLN. An experienced radiologist, masked to histology, retrospectively reviewed all fused SPECT/MR images and scored morphologic SLN parameters on a standardized case report form. Logistic regression and receiver-operating curves were used to model the parameters against the SLN status. In 75 cases, 136 SLNs were eligible for analysis, of which 13 (9.6%) contained metastases (8 cases). Three parameters-short-axis diameter, long-axis diameter, and absence of sharp demarcation-significantly predicted metastatic invasion of nonenlarged SLNs, with quality-adjusted odds ratios of 1.42 (95% confidence interval [CI], 1.01-1.99), 1.28 (95% CI, 1.03-1.57), and 7.55 (95% CI, 1.09-52.28), respectively. The area under the curve of the receiver-operating curves combining these parameters was 0.749 (95% CI, 0.569-0.930). Heterogeneous gadolinium enhancement, cortical thickness, round shape, or SLN size, compared with the nearest non-SLN, showed no association with metastases (P= 0.055-0.795). In cervical cancer patients without enlarged lymph nodes, selective evaluation of only the SLNs-for size and absence of sharp demarcation-can be used to noninvasively assess the presence of metastases. © 2016 by the Society of Nuclear Medicine and Molecular Imaging, Inc.
Laparoendoscopic Single-Site Sentinel Lymph Node Detection in Endometrial Cancer.
Demirayak, Gökhan; Comba, Cihan; Özdemir, İsa Aykut
2017-11-13
To demonstrate the feasibility of sentinel lymph node (SLN) biopsy using a laparoendoscopic single-site (LESS) approach in endometrial cancer (EC). A step-by-step video demonstration of the surgical procedure (Canadian Task Force Classification III). The satisfaction of patients who undergo LESS hysterectomy is greater than that reported by patients who undergo multiport laparoscopic hysterectomy, owing to better cosmesis and reduced postoperative analgesic requirements [1]. SLN biopsy is associated with significantly lower estimated blood loss, shorter operation time, and less morbidity compared with systematic lymphadenectomy [2]. LESS surgery can be more feasible and safer with the use of SLN biopsy compared with complete lymphadenectomy in patients with early-stage EC. This 69-year-old woman with grade 2 endometrioid EC underwent SLN mapping followed by LESS SLN biopsy, total hysterectomy, and bilateral salpingo-oophorectomy. Before the umbilical incision was made, 1.25 mg/mL of indocyanine green was injected into the cervical stroma at the 3 o'clock and 9 o'clock positions to both deep and superficial levels. A 10-mm 30° standard-length optical camera for near-infrared fluorescence imaging was used. The total operative time was 75 minutes, and the estimated blood loss was 20 mL. SLNs were detected bilaterally between proximal parts of the external iliac arteries and veins. After SLN resection, total hysterectomy and bilateral salpingo-oophorectomy were performed. No postoperative complications occurred. The patient was discharged at 30 hours after surgery. In the final pathology, stage 1A G2 EC was detected. LESS SLN biopsy and TLH-BSO is a feasible procedure and sentinel lymph node concept may increase the use of LESS in EC. Copyright © 2017 American Association of Gynecologic Laparoscopists. Published by Elsevier Inc. All rights reserved.
Kara, P Pelin; Ayhan, Ali; Caner, Biray; Gültekin, Murat; Ugur, Omer; Bozkurt, M Fani; Usubutun, Alp
2008-07-01
The objective of this prospective study was to determine the feasibility of sentinel lymph node (SLN) detection in patients with cervical cancer using lymphoscintigraphy (LS), gamma probe, and blue dye. A total of 32 patients with early stage cervical cancer (FIGO IA2-IIA) who were treated with total abdominal hysterectomy and bilateral pelvic and paraortic lymphadenectomy underwent SLN biopsy. LS was performed on all the patients following the injection of 74 MBq technetium-99m-nanocolloid pericervically. The first appearing persistent focal accumulation on either dynamic or static images of LS was considered to be an SLN. Blue dye was injected just prior to surgical incision in 16 patients (50%) at the same locations as the radioactive isotope injection. During the operation, blue-stained node(s) were excised as SLNs. For gamma probe, a lymph node was accepted as an SLN, if its ex vivo radioactive counts were at least 10-fold above background radioactivity. SLNs, which were negative by routine hematoxylin and eosin (H&E) examination, were histopathologically reevaluated for the presence of micrometastases by step sectioning and immunohistochemical staining with pancytokeratin. At least one SLN was identified for each patient by gamma probe. Intraoperative gamma probe was the most sensitive method with a technical success rate of SLN detection of 100% (32/32), followed by LS 87.5% (28/32) and blue dye 68.8% (11/16), respectively. The average number of SLNs per patient detected by gamma probe was 2.09 (range 1-5). The localizations of the SLNs were external iliac 47.8%, obturatory 32.8%, common iliac 9%, paraaortic 4.4%, and paracervical 6%. Micrometastases, not detected by routine H&E were found by immunohistochemistry in one patient. On the basis of the histopathological analysis, the negative predictive value for predicting metastases was 100%, and there were no false-negative results. Preoperative LS with radiocolloids, intraoperative lymphatic mapping with blue dye and gamma probe are all feasible methods comparable with each other for SLN detection in early stage cervical cancer patients, but gamma probe is the most useful method in terms of technical success.
Wallace, Anne M; Han, Linda K; Povoski, Stephen P; Deck, Kenneth; Schneebaum, Schlomo; Hall, Nathan C; Hoh, Carl K; Limmer, Karl K; Krontiras, Helen; Frazier, Thomas G; Cox, Charles; Avisar, Eli; Faries, Mark; King, Dennis W; Christman, Lori; Vera, David R
2013-08-01
Sentinel lymph node (SLN) surgery is used worldwide for staging breast cancer patients and helps limit axillary lymph node dissection. [(99m)Tc]Tilmanocept is a novel receptor-targeted radiopharmaceutical evaluated in 2 open-label, nonrandomized, within-patient, phase 3 trials designed to assess the lymphatic mapping performance. A total of 13 centers contributed 148 patients with breast cancer. Each patient received [(99m)Tc]tilmanocept and vital blue dye (VBD). Lymph nodes identified intraoperatively as radioactive and/or blue stained were excised and histologically examined. The primary endpoint, concordance (lower boundary set point at 90 %), was the proportion of nodes detected by VBD and [(99m)Tc]tilmanocept. A total of 13 centers contributed 148 patients who were injected with both agents. Intraoperatively, 207 of 209 nodes detected by VBD were also detected by [(99m)Tc]tilmanocept for a concordance rate of 99.04 % (p < 0.0001). [(99m)Tc]tilmanocept detected a total of 320 nodes, of which 207 (64.7 %) were detected by VBD. [(99m)Tc]Tilmanocept detected at least 1 SLN in more patients (146) than did VBD (131, p < 0.0001). In 129 of 131 patients with ≥1 blue node, all blue nodes were radioactive. Of 33 pathology-positive nodes (18.2 % patient pathology rate), [(99m)Tc]tilmanocept detected 31 of 33, whereas VBD detected only 25 of 33 (p = 0.0312). No pathology-positive SLNs were detected exclusively by VBD. No serious adverse events were attributed to [(99m)Tc]tilmanocept. [(99m)Tc]Tilmanocept demonstrated success in detecting a SLN while meeting the primary endpoint. Interestingly, [(99m)Tc]tilmanocept was additionally noted to identify more SLNs in more patients. This localization represented a higher number of metastatic breast cancer lymph nodes than that of VBD.
A Receptor-targeted Fluorescent Radiopharmaceutical for Multireporter Sentinel Lymph Node Imaging
Emerson, Derek K.; Limmer, Karl K.; Hall, David J.; Han, Sung-Ho; Eckelman, William C.; Kane, Christopher J.; Wallace, Anne M.
2012-01-01
Purpose: To determine the imaging and receptor-binding properties of a multireporter probe designed for sentinel lymph node (SLN) mapping via nuclear and fluorescence detection. Materials and Methods: The animal experiments were approved by the institutional animal care and use committee. A multireporter probe was synthesized by covalently attaching cyanine 7 (Cy7), a near-infrared cyanine dye, to tilmanocept, a radiopharmaceutical that binds to a receptor specific to recticuloendothelial cells. In vitro binding assays of technetium 99m (99mTc) -labeled Cy7 tilmanocept were conducted at 4°C by using receptor-bearing macrophages. Optical SLN imaging after foot pad administration was performed by using two molar doses of Cy7 tilmanocept. Six mice were injected with 0.11 nmol of 99mTc-labeled Cy7 tilmanocept (low-dose group); an additional six mice were injected with 31 nmol of 99mTc-labeled Cy7 tilmanocept (high-dose group) to saturate the receptor sites within the SLN. After 2.5 hours of imaging, the mice were euthanized, and the sentinel and distal lymph nodes were excised and assayed for radioactivity for calculation of SLN percentage of injected dose and extraction. Four mice were used as controls for autofluorescence. Standard optical imaging software was used to plot integrated fluorescence intensity against time for calculation of the SLN uptake rate constant and scaled peak intensity. Significance was calculated by using the Student t test. Results: In vitro binding assays showed subnanomolar affinity (mean dissociation constant, 0.25 nmol/L ± 0.10 [standard deviation]). Fluorescence imaging showed a detection sensitivity of 1.6 × 103 counts · sec−1 · μW−1 per picomole of Cy7. All four imaging metrics (percentage of injected dose, SLN extraction, SLN uptake rate constant, and expected peak fluorescence intensity) exhibited higher values (P = .005 to P = .042) in the low-dose group than in the high-dose group; this finding was consistent with receptor-mediated image formation. Conclusion: The multireporter probe 99mTc-labeled Cy7 tilmanocept exhibits in vitro and in vivo receptor-binding properties for successful receptor-targeted SLN mapping with nuclear and optical imaging. © RSNA, 2012 Supplemental material: http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.12120638/-/DC1 PMID:22753678
Sentinel lymph node detection in gynecologic malignancies by a handheld fluorescence camera
NASA Astrophysics Data System (ADS)
Hirsch, Ole; Szyc, Lukasz; Muallem, Mustafa Zelal; Ignat, Iulia; Chekerov, Radoslav; Macdonald, Rainer; Sehouli, Jalid; Braicu, Ioana; Grosenick, Dirk
2017-02-01
Near-infrared fluorescence imaging using indocyanine green (ICG) as a tracer is a promising technique for mapping the lymphatic system and for detecting sentinel lymph nodes (SLN) during cancer surgery. In our feasibility study we have investigated the application of a custom-made handheld fluorescence camera system for the detection of lymph nodes in gynecological malignancies. It comprises a low cost CCD camera with enhanced NIR sensitivity and two groups of LEDs emitting at wavelengths of 735 nm and 830 nm for interlaced recording of fluorescence and reflectance images of the tissue, respectively. With the help of our system, surgeons can observe fluorescent tissue structures overlaid onto the anatomical image on a monitor in real-time. We applied the camera system for intraoperative lymphatic mapping in 5 patients with vulvar cancer, 5 patients with ovarian cancer, 3 patients with cervical cancer, and 3 patients with endometrial cancer. ICG was injected at four loci around the primary malignant tumor during surgery. After a residence time of typically 15 min fluorescence images were taken in order to visualize the lymph nodes closest to the carcinomas. In cases with vulvar cancer about half of the lymph nodes detected by routinely performed radioactive SLN mapping have shown fluorescence in vivo as well. In the other types of carcinomas several lymph nodes could be detected by fluorescence during laparotomy. We conclude that our low cost camera system has sufficient sensitivity for lymphatic mapping during surgery.
Use of sentinel lymph node biopsy for melanoma of the head and neck.
Kilpatrick, Lauren A; Shen, Perry; Stewart, John H; Levine, Edward A
2007-08-01
Sentinel lymph node biopsy (SLN) is a well-accepted procedure for truncal and extremity melanoma (T&E). However, its role in melanoma of the head and neck (H&N) remains controversial. Complex lymphatic and vascular drainage make SLN more challenging in this region. This study was done to evaluate the results of SLN for H&N versus T&E melanoma. Three hundred sixteen patients who underwent SLN for melanoma using a double indicator technique were identified from a prospective database. Records were analyzed retrospectively. Statistical analysis was performed using chi2, t test, or Mann-Whitney U test to evaluate the results, as appropriate. H&N was found in 87 cases (27.5%). The mean age was 63.2 and 53.2 years for H&N and T&E melanoma (P < 0.001), respectively. 99Technetium positivity (89.7% H&N versus 99.6% T&E, P < 0.001) and isosulfan blue positivity (85.1% H&N versus 91.7% T&E, P = 0.08) were more likely in T&E melanoma. There was a significant difference between H&N and T&E melanoma with respect to the incidence of failed SLN, defined as no sentinel nodes identified intraoperatively (8.0% versus 0%, P < 0.001). Both groups had similar rates of positive intraoperative imprint cytologic examination (4.6% H&N versus 6.1% T&E, P > 0.5). There was a trend suggesting a higher mean number of sentinel lymph nodes found (3.1 versus 2.7, P = 0.1) in H&N melanoma. The total number of lymph nodes found in dissection specimens (20.9 versus 21.9, P = 0.45), the total number of positive lymph nodes (3.5 versus 1.6, P = 0.32), the incidence of any recurrence (19.5% versus 12.7%, P = 0.2), and time to recurrence (14.2 versus 20.6 months, P = 0.18) were similar between H&N and T&E melanoma. SLN mapping of H&N lesions is more difficult than at other sites. However, rates of nodal positivity are similar to melanoma of the trunk and extremities. Therefore, despite being more demanding, SLN is useful in diagnosis and treatment of melanomas of the head and neck.
Martínez, A; Zerdoud, S; Mery, E; Bouissou, E; Ferron, G; Querleu, D
2010-12-01
Conventional lymphoscintigraphy provides planar images with little spatial information on location of pelvic sentinel lymph nodes (SLN). SPECT has better spatial resolution and, in combination with anatomic accuracy provided by CT improves SLN preoperative localization. The aim of the study was to report on the results of hybrid imaging of SLN in early cervical cancer patients treated at Claudius Regaud Cancer Center. Stages IA-IB1 cervical cancer patients undergoing preoperative SPECT/CT for SLN detection were analysed. Forty-one patients were included. A 100% SLN detection rate was achieved when a combined technique (radiotracer and blue dye) was used. At least one SLN was clearly visualized by SPECT/CT in 39 of 41 patients (95%) and full anatomic concordance with intraoperative anatomical location of SLN was found in 37 of the 39 patients with at least one SLN identified by SPECT/CT (95%). Location of removed SLN included the external and internal iliac area in 88% patients, the common iliac area in 10.5%, and the inframesenteric para-aortic area in 1.5%. No SLN was found in the infrarenal para-aortic region. Lymph node involvement was identified in 5 patients (12.1%). SLN correctly predicted lymph node involvement in all node-positive patients. However, SPECT/CT failed to identify 1 of the 5 metastatic SLN. SPECT/CT accurately detected preoperative SLN topography and enhanced diagnostic sensitivity of SLN imaging, improving surgical approach to patients with cervical cancer staging. Diagnostic quality of anatomic landmarks of CT images of SPECT/CT could be further improved by the use of contrast injected CT. Copyright © 2010 Elsevier Inc. All rights reserved.
[Sentinel node detection in early stage of cervical carcinoma using 99mTc-nanocolloid and blue dye].
Sevcík, L; Klát, J; Gráf, P; Koliba, P; Curík, R; Kraft, O
2007-04-01
The aim of the study was to analyse the feasibility of intraoperative sentinel lymph nodes (SLN) detection using gamma detection probe and blue dye in patients undergoing radical hysterectomy for treatment of early stage of cervical cancer. Prospective case observational study. In the period from May 2004 to February 2006 77 patients with early stage of cervical cancer who underwent a radical surgery were included into the study. Patients were divided into three groups according to the tumour volume. First group consists of patients FIGO IA2 and FIGO IB1 with tumour diameter less than 2 cm, second group tumours FIGO IB1 with tumour diameter more than 2 cm and third group stadium IB2. SLN was detected by blue dye and Tc99. Preoperative lymphoscintigraphy was done after Tc99 colloid injection, intraoperative detection was performed by visual observation and by hand-held gamma-detection probe. SLN were histologically and immunohistochemically analysed. A total number of 2764 lymph nodes with an average 36 and 202 SLN with an average 2.6 were identified. The SLN detection rate was 94.8% per patient and 85.1% for the side of dissection and depends on the tumor volume. SLN were identified in obturator area in 48%, in external iliac area in 15%, in common iliac and internal iliac both in 9%, in interiliac region in 8%, in praesacral region in 6% and in parametrial area in 5%. Metastatic disease was detected in 31 patients (40.2%), metastatic involvement of SLN only in 12 patients (15.6%). False negative rate was 2.6%, sensitivity and negative predictive value calculated by patient were 923% and 95.7%. Intraoperative lymphatic mapping using combination of technecium-99-labeled nanocolloid and blue dye are feasible, safe and accurate techniques to identified SLN in early stage of cervical cancer.
Inoue, Tomoo; Nishi, Toshio; Nakano, Yoshiaki; Nishimae, Ayaka; Sawai, Yuka; Yamasaki, Masaru; Inaji, Hideo
2016-03-01
There is limited information on indocyanine green (ICG) fluorescence and blue dye for detecting sentinel lymph node (SLN) in early breast cancer. A retrospective study was conducted to assess the feasibility of an SLN biopsy using the combination of ICG fluorescence and the blue dye method. Seven hundred and fourteen patients with clinically node-negative breast cancer were included in this study. They underwent SLN biopsy using a combination of ICG fluorescence and the blue dye method from March 2007 to February 2014. The ICG (a fluorescence-emitting source) and patent blue (the blue dye) were injected into the patients' subareolar region. The removed lymph nodes that had ICG fluorescence and/or blue dye uptake were defined as SLNs. The results of the SLN biopsies and follow-up results of patients who underwent SLN biopsy alone were investigated. In 711 out of 714 patients, SLNs were identified by a combination of ICG fluorescence and the blue dye method (detection rate, 99.6 %). The average number of SLNs was 2.4 (range 1-7), and the average number of resected swollen para-SLNs was 0.4 (range 0-5). Ninety-nine patients with an SLN and/or para-SLN involvement during the intraoperative pathological diagnosis underwent axillary lymph node resection (ALND). In addition, two of three patients whose SLN was not identified also underwent ALND. In 46 of 101 patients with an ALND, non-SLN involvement was not found. Follow-up results were analyzed in 464 patients with invasive carcinoma excluding those with ductal carcinoma in situ (n = 148) and those who underwent ALND (n = 101). During the follow-up period (range 4.4-87.7 months; median, 38 months), two patients (0.4 %) developed axillary lymph node recurrence. They were successfully salvaged, and to date, no further locoregional recurrence has been observed. A high rate of SLN detection and low rate of axillary lymph node recurrence were confirmed by an SLN biopsy using a combination of ICG fluorescence and the blue dye method. Therefore, it is suggested that this method may replace the combination of dye and radioisotope methods.
Boughey, Judy C.; Ballman, Karla V.; Hunt, Kelly K.; McCall, Linda M.; Mittendorf, Elizabeth A.; Ahrendt, Gretchen M.; Wilke, Lee G.; Le-Petross, Huong T.
2015-01-01
Purpose The American College of Surgeons Oncology Group Z1071 trial reported a 12.6% false-negative rate (FNR) for sentinel lymph node (SLN) surgery after neoadjuvant chemotherapy (NAC) in cN1 disease. Patients were not selected for surgery based on response, but a secondary end point was to determine whether axillary ultrasound (AUS) after NAC after fine-needle aspiration cytology can identify abnormal nodes and guide patient selection for SLN surgery. Patients and Methods Patients with T0-4, N1-2, M0 breast cancer underwent AUS after neoadjuvant chemotherapy. AUS images were centrally reviewed and classified as normal or suspicious lymph nodes. AUS findings were tested for association with pathologic nodal status and SLN FNR. The impact of AUS results to select patients for SLN surgery to reduce the FNR was assessed. Results Postchemotherapy AUS images were reviewed for 611 patients. One hundred thirty (71.8%) of 181 AUS-suspicious patients were node positive at surgery compared with 243 (56.5%) of 430 AUS-normal patients (P < .001). Patients with AUS-suspicious nodes had a greater number of positive nodes and greater metastasis size (P < .001). The SLN FNR was not different based on AUS results; however, using a strategy where only patients with normal AUS undergo SLN surgery would potentially reduce the FNR in Z1071 patients with ≥ two SLNs removed from 12.6% to 9.8% when preoperative AUS results are considered as part of SLN surgery. Conclusion AUS is recommended after chemotherapy to guide axillary surgery. An FNR of 9.8% with the combination of AUS and SLN surgery would be acceptable for the adoption of SLN surgery for women with node-positive breast cancer treated with neoadjuvant chemotherapy. PMID:25646192
Boughey, Judy C; Ballman, Karla V; Hunt, Kelly K; McCall, Linda M; Mittendorf, Elizabeth A; Ahrendt, Gretchen M; Wilke, Lee G; Le-Petross, Huong T
2015-10-20
The American College of Surgeons Oncology Group Z1071 trial reported a 12.6% false-negative rate (FNR) for sentinel lymph node (SLN) surgery after neoadjuvant chemotherapy (NAC) in cN1 disease. Patients were not selected for surgery based on response, but a secondary end point was to determine whether axillary ultrasound (AUS) after NAC after fine-needle aspiration cytology can identify abnormal nodes and guide patient selection for SLN surgery. Patients with T0-4, N1-2, M0 breast cancer underwent AUS after neoadjuvant chemotherapy. AUS images were centrally reviewed and classified as normal or suspicious lymph nodes. AUS findings were tested for association with pathologic nodal status and SLN FNR. The impact of AUS results to select patients for SLN surgery to reduce the FNR was assessed. Postchemotherapy AUS images were reviewed for 611 patients. One hundred thirty (71.8%) of 181 AUS-suspicious patients were node positive at surgery compared with 243 (56.5%) of 430 AUS-normal patients (P < .001). Patients with AUS-suspicious nodes had a greater number of positive nodes and greater metastasis size (P < .001). The SLN FNR was not different based on AUS results; however, using a strategy where only patients with normal AUS undergo SLN surgery would potentially reduce the FNR in Z1071 patients with ≥ two SLNs removed from 12.6% to 9.8% when preoperative AUS results are considered as part of SLN surgery. AUS is recommended after chemotherapy to guide axillary surgery. An FNR of 9.8% with the combination of AUS and SLN surgery would be acceptable for the adoption of SLN surgery for women with node-positive breast cancer treated with neoadjuvant chemotherapy. © 2015 by American Society of Clinical Oncology.
Cong, Bin-Bin; Sun, Xiao; Song, Xian-Rang; Liu, Yan-Bing; Zhao, Tong; Cao, Xiao-Shan; Qiu, Peng-Fei; Tian, Chong-Lin
2016-01-01
An appropriate receptor-targeted tracer for sentinel lymph node biopsy (SLNB) was prepared. We combined the fluorescence tracer (Indocyanine green, ICG) with Rituximab (a chimeric human/murine monoclonal antibody targeting the CD20 antigen on the surface of lymphocyte) directly to produce a new tracer (ICG-Rituximab). When the new tracer drains to the lymph node, Rituximab will combine with CD20 receptor on the B-cell surface in the lymph node. If the statue of antibody-receptor connection does not reach saturation, the number of Rituximab is less than CD20. With this appropriate injection dose, the new tracer could only stay in sentinel lymph node (SLN) and make it imaging. Positive fluorescence SLN was detected 12 minutes after injection with no other organs imaging. The imaging of SLN was stable and clear for 20–24 hours. Due to SLN stained with more ICG than the lymphatic vessel, the fluorescence situation of SLN would be brighter than the vessel. The surgeon can detect the positive fluorescence SLN easily without following the fluorescence imaging lymphatic vessel. The results of our preliminary study showed that the new tracer might be useful for improving SLN imaging and worth further clinical study. SLNB with the new tracer could be a convenient method for detecting SLN and would become a standard performance in clinical practice. PMID:27374088
Cong, Bin-Bin; Sun, Xiao; Song, Xian-Rang; Liu, Yan-Bing; Zhao, Tong; Cao, Xiao-Shan; Qiu, Peng-Fei; Tian, Chong-Lin; Yu, Jin-Ming; Wang, Yong-Sheng
2016-07-26
An appropriate receptor-targeted tracer for sentinel lymph node biopsy (SLNB) was prepared. We combined the fluorescence tracer (Indocyanine green, ICG) with Rituximab (a chimeric human/murine monoclonal antibody targeting the CD20 antigen on the surface of lymphocyte) directly to produce a new tracer (ICG-Rituximab). When the new tracer drains to the lymph node, Rituximab will combine with CD20 receptor on the B-cell surface in the lymph node. If the statue of antibody-receptor connection does not reach saturation, the number of Rituximab is less than CD20. With this appropriate injection dose, the new tracer could only stay in sentinel lymph node (SLN) and make it imaging. Positive fluorescence SLN was detected 12 minutes after injection with no other organs imaging. The imaging of SLN was stable and clear for 20-24 hours. Due to SLN stained with more ICG than the lymphatic vessel, the fluorescence situation of SLN would be brighter than the vessel. The surgeon can detect the positive fluorescence SLN easily without following the fluorescence imaging lymphatic vessel. The results of our preliminary study showed that the new tracer might be useful for improving SLN imaging and worth further clinical study. SLNB with the new tracer could be a convenient method for detecting SLN and would become a standard performance in clinical practice.
Bañuelos-Andrío, Luis; Rodríguez-Caravaca, Gil; Argüelles-Pintos, Miguel; Mitjavilla-Casanovas, Mercedes
2014-01-01
The method for intraoperative sentinel lymph node (SLN) evaluation has still not been established in breast cancer staging. This study has evaluated the diagnostic validity and impact of intraoperative analysis using the frozen section (FS) of SLN. We performed a descriptive study of the diagnostic validity of the FS of the SLN in patients with breast cancer and selective sentinel node biopsy (SSNB) from October-2006 to October-2012. The diagnostic validity indexes were evaluated using sensitivity, specificity, positive and negative predictive values and global value. Gold standard was considered as the final histopathological results of the biopsies. A total of 370 patients were studied. Sensitivity and specificity for detection of metastasis by FS in the SLN were 67% and 100%, respectively. Global diagnostic validity was 95%. There was a correlation between detection of metastasis and tumor size (p<0.05). Twelve of the 15 patients with SLN micro-metastases underwent axillary lymph node dissection (ALND). Metastatic lymph nodes were not found in any of them. Intraoperative FS examination of the SLN is a useful and reliable predictor of axillary lymph node staging in patients with initial stages of breast cancer. FS reduces the need for second interventions, at least for most patients who have breast cancer with identifiable positive SLN and unequivocal evidence of positive lymph node disease. Copyright © 2013 Elsevier España, S.L. and SEMNIM. All rights reserved.
Sentinel Lymph Nodes for Breast Carcinoma: An Update on Current Practice
Maguire, Aoife; Brogi, Edi
2016-01-01
Sentinel lymph node (SLN) biopsy has been established as the standard of care for axillary staging in patients with invasive breast carcinoma and clinically negative lymph nodes (cN0). Historically, all patients with a positive SLN underwent axillary lymph node dissection (ALND). The ACOSOG Z0011 trial showed that women with T1-T2 disease and cN0 who undergo breast conserving surgery and whole-breast radiotherapy can safely avoid ALND. The main goal of SLN examination should be to detect all macrometastases (>2mm). Gross sectioning SLNs at 2 mm intervals and microscopic examination of one H&E-stained section from each SLN block is the preferred method of pathologic evaluation of SLNs. The role and timing of SLN biopsy for patients having neoadjuvant chemotherapy is controversial and continues to be explored in clinical trials. SLN biopsies from patients with invasive breast carcinoma who have received neoadjuvant chemotherapy pose particular challenges for pathologists. PMID:26768036
Unkart, Jonathan T; Wallace, Anne M
2017-09-01
99m Tc-tilmanocept received recent Food and Drug Administration approval for lymphatic mapping in 2013. However, to our knowledge, no prior studies have evaluated the use of 99m Tc-tilmanocept as a single agent in sentinel lymph node (SLN) biopsy in breast cancer. Methods: We executed this retrospective pilot study to assess the ability of 99m Tc-tilmanocept to identify sentinel nodes as a single agent in clinically node-negative breast cancer patients. Patients received a single intradermal injection overlying the tumor of either 18.5 MBq (0.5 mCi) of 99m Tc-tilmanocept on the day of surgery or 74.0 MBq (2.0 mCi) on the day before surgery by a radiologist. Immediate 3-view lymphoscintigraphy was performed. Intraoperatively, SLNs were identified with a portable γ-probe. A node was classified as hot if the count (per second) of the node was more than 3 times the background count. Descriptive statistics are reported. Results: Nineteen patients underwent SLN biopsy with single-agent 99m Tc-tilmanocept. Immediate lymphoscintigraphy identified at least 1 sentinel node in 13 of 17 patients (76.5%). Intraoperatively, at least 1 (mean, 1.7 ± 0.8; range, 1-3) hot node was identified in all patients. Three patients (15.8%) had 1 disease-positive SLN. Conclusion: In this small, retrospective pilot study, 99m Tc-tilmanocept performed well as a single agent for intraoperative sentinel node identification in breast cancer. A larger, randomized clinical trial is warranted to compare 99m Tc-tilmanocept as a single agent with other radiopharmaceuticals for sentinel node identification in breast cancer. © 2017 by the Society of Nuclear Medicine and Molecular Imaging.
Kato, Hidenori; Todo, Yukiharu; Minobe, Shin-Ichiro; Suzuki, Yoshihiro; Nakatani, Makiko; Ohba, Yoko; Yamashiro, Katsusige; Okamoto, Kazuhira
2011-11-01
Sentinel lymph node (SLN) detection has been accepted as a common strategy to preserve the quality of life of the patients with gynecologic cancers. However, the feasibility of SLN detection after conization is not yet clarified. Accuracy of SLN after conization was evaluated. Eighteen cases with prior conization (cone group) and 32 cases without conization (noncone group), all of which belonged to IB1 except 1 case in IA stage, underwent SLN detection. Systemic pelvic and para-aortic lymphadenectomy was coincidently performed for the estimation of negative and positive predictive values. Detection rate in which at least unilateral nodes were identified or bilaterally identified was 100% and 72.2% in the cone group, 90.6% and 71.9% in the noncone group, respectively. The average number of the detected SLN was 2.4 in the cone group and 2.1 in the noncone group. Negative and positive predictive value was 100% in both groups. On the distribution of sentinel node stations, most of the detected nodes were internal iliac and obturator node in both groups. Less frequent detection was observed in superficial common iliac node (5.4% in the cone group, 3.1% in the noncone group), external iliac node (2.7% and 9.5%), and parauterine artery node (5.4% and 1.6%).In both groups, no other lymph nodes were identified as SLN except 1 case in the cone group with the node in cardinal ligament. No significant difference was observed on detection rate, predictive value, and the distribution of sentinel node between the cone and noncone groups. Sentinel lymph node detection after conization can be performed with a certain reliability.
Adachi, Yayoi; Sawaki, Masataka; Hattori, Masaya; Yoshimura, Akiyo; Gondo, Noami; Kotani, Haruru; Iwase, Madoka; Kataoka, Ayumi; Onishi, Sakura; Sugino, Kayoko; Terada, Mitsuo; Horisawa, Nanae; Mori, Makiko; Oze, Isao; Iwata, Hiroji
2018-03-13
Recent studies suggested that ALND (axillary lymph node dissection) can be avoided in breast cancer patients with limited SLN (sentinel lymph node) metastasis. However, these trials included only several invasive lobular carcinoma (ILC) cases, and the validity of omitting ALND for ILC remains controversial. Here, we examined whether omitting ALND is feasible in ILC treatment. A total of 3771 breast cancer patients underwent surgery for breast cancer at the Aichi Cancer Center Hospital between January 2006 and December 2015. We excluded patients with neoadjuvant therapy or without axillary management, and identified 184 ILC patients and 2402 invasive ductal carcinoma (IDC) patients. We compared SLN and non-SLN metastasis rates and the number of total ALN metastases between the ILC and IDC cohorts, and we examined the factors that influenced non-SLN metastasis in the SLN micrometastasis group. SLN biopsies were performed in 171 (93%) ILC and 2168 (90%) IDC cases, and 31 (18%) ILC and 457 (21%) IDC cases were SLN micrometastasis and macrometastasis (p = 0.36). Among SLN macrometastasis patients, 17 (68%) ILC cases and 163 (46%) IDC cases showed non-SLN metastasis (p = 0.03). The number of non-SLN metastases was greater in ILC cases compared with IDC cases. Multivariate analysis showed that ILC was the influential factor predicting non-SLN metastasis in patients with SLN macrometastasis. ILC cases had more non-SLN metastasis than IDC cases among SLN-positive cases, and ILC was an important factor for the prediction of non-SLN positivity in SLN macrometastasis cases. Omitting ALND for ILC with positive SLNs requires more consideration.
Rios-Cantu, Andrei; Lu, Ying; Melendez-Elizondo, Victor; Chen, Michael; Gutierrez-Range, Alejandra; Fadaki, Niloofar; Thummala, Suresh; West-Coffee, Carla; Cleaver, James; Kashani–Sabet, Mohammed
2018-01-01
Melanoma patients with additional positive lymph nodes in the completion lymph node dissection (CLND) following a positive sentinel lymph node (SLN) biopsy would have a poorer prognosis than patients with no additional positive lymph nodes. We hypothesize that the progression of disease from the SLN to the non-SLN compartment is orderly and is associated with the worsening of the disease status. Thus, the SLN and non-SLN compartments are biologically different in that cancer cells, in general, arrive in the SLN compartment before spreading to the non-SLN compartment. To validate this concept, we used a large cohort of melanoma patients from our prospective SLN database in an academic tertiary medical center. Adult cutaneous melanoma patients (n = 291) undergoing CLND after a positive SLN biopsy from 1994 to 2009 were analyzed. Comparison of 5-year disease-free survival and 5-year overall survival between positive (n = 66) and negative (n = 225) CLND groups was made. The 5-year disease-free survival rates were 55% (95% CI 49–62%) for patients with no additional LN on CLND versus 14% (95% CI 8–26%) in patients with positive LN on CLND (p < 0.0001, log-rank test). The median disease-free survival time was 7.4 years with negative CLND (95% CI 4.4–15+ years) and 1.2 years with positive CLND (95% CI 1.0–1.8 years). The 5-year overall survival rates were 67% (95% CI 61–74%) for negative CLND versus 38% (95% CI 28–52%) for positive CLND (p < 0.0001, log-rank test). The median overall survival time was 12.1 years for negative CLND (95% CI 9.3–15+ years) and 2.5 years for positive CLND (95% CI 2.2–5.7 years). This study shows that CLND status is a significant prognostic factor for patients with positive SLNs undergoing CLND. Also, it suggests an orderly progression of metastasis from the SLN to the non-SLN compartment. Thus, the SLN in the regional nodal basin draining the primary melanoma may serve as an important gateway for metastasis to the non-SLN compartment and beyond to the systemic sites. PMID:28699042
Rios-Cantu, Andrei; Lu, Ying; Melendez-Elizondo, Victor; Chen, Michael; Gutierrez-Range, Alejandra; Fadaki, Niloofar; Thummala, Suresh; West-Coffee, Carla; Cleaver, James; Kashani-Sabet, Mohammed; Leong, Stanley P L
2017-06-01
Melanoma patients with additional positive lymph nodes in the completion lymph node dissection (CLND) following a positive sentinel lymph node (SLN) biopsy would have a poorer prognosis than patients with no additional positive lymph nodes. We hypothesize that the progression of disease from the SLN to the non-SLN compartment is orderly and is associated with the worsening of the disease status. Thus, the SLN and non-SLN compartments are biologically different in that cancer cells, in general, arrive in the SLN compartment before spreading to the non-SLN compartment. To validate this concept, we used a large cohort of melanoma patients from our prospective SLN database in an academic tertiary medical center. Adult cutaneous melanoma patients (n = 291) undergoing CLND after a positive SLN biopsy from 1994 to 2009 were analyzed. Comparison of 5-year disease-free survival and 5-year overall survival between positive (n = 66) and negative (n = 225) CLND groups was made. The 5-year disease-free survival rates were 55% (95% CI 49-62%) for patients with no additional LN on CLND versus 14% (95% CI 8-26%) in patients with positive LN on CLND (p < 0.0001, log-rank test). The median disease-free survival time was 7.4 years with negative CLND (95% CI 4.4-15+ years) and 1.2 years with positive CLND (95% CI 1.0-1.8 years). The 5-year overall survival rates were 67% (95% CI 61-74%) for negative CLND versus 38% (95% CI 28-52%) for positive CLND (p < 0.0001, log-rank test). The median overall survival time was 12.1 years for negative CLND (95% CI 9.3-15+ years) and 2.5 years for positive CLND (95% CI 2.2-5.7 years). This study shows that CLND status is a significant prognostic factor for patients with positive SLNs undergoing CLND. Also, it suggests an orderly progression of metastasis from the SLN to the non-SLN compartment. Thus, the SLN in the regional nodal basin draining the primary melanoma may serve as an important gateway for metastasis to the non-SLN compartment and beyond to the systemic sites.
Poumellec, M-A; Dejode, M; Figl, A; Darcourt, J; Haudebourg, J; Sabah, Y; Voury, A; Martaens, A; Barranger, E
2016-04-01
Assess the biopsy's feasibility of the sentinel lymph node biopsy (SLNB) using optonuclear probe after of indocyanine green (ICG) and radio-isotope (RI) injections. Twenty-one patients with a localized breast cancer and unsuspicious axillary nodes underwent a SLNB after both injections of ICG and radio-isotope. One or more SLN were identified on the 21 patients (identification rate of 100%). The median number SLN was 2 (1-3). Twenty SLN were both radio-actives and fluorescents (54.1%), 11 fluorescent only (29.7%) and 6 were only radio-actives (16.2%). Seven patients had a metastatic SLN (8 SLN overall). Among them, only one had a micrometastasic SLN, 5 others had a macrometastatic SLN and one patient had two macrometastatic SLNs. Among the 8 metastatic SLN, 5 were both fluorescent and radioactive, 2 were only fluorescent and 1 was only radioactive. Detection SLN using optonuclear probe after indocyanine green and radio-isotope injections is effective and could be, after validation by randomized trial, a reliable alternative to the blue dye injection for teams who consider that combined detection as the reference. Copyright © 2016 Elsevier Masson SAS. All rights reserved.
Nguyen, Daniel P; Huber, Philipp M; Metzger, Tobias A; Genitsch, Vera; Schudel, Hans H; Thalmann, George N
2016-11-01
Sentinel lymph node (SLN) detection techniques have the potential to change the standard of surgical care for patients with prostate cancer. We performed a lymphatic mapping study and determined the value of fluorescence SLN detection with indocyanine green (ICG) for the detection of lymph node metastases in intermediate- and high-risk patients undergoing radical prostatectomy and extended pelvic lymph node dissection. A total of 42 patients received systematic or specific ICG injections into the prostate base, the midportion, the apex, the left lobe, or the right lobe. We found (1) that external and internal iliac regions encompass the majority of SLNs, (2) that common iliac regions contain up to 22% of all SLNs, (3) that a prostatic lobe can drain into the contralateral group of pelvic lymph nodes, and (4) that the fossa of Marcille also receives significant drainage. Among the 12 patients who received systematic ICG injections, 5 (42%) had a total of 29 lymph node metastases. Of these, 16 nodes were ICG positive, yielding 55% sensitivity. The complex drainage pattern of the prostate and the low sensitivity of ICG for the detection of lymph node metastases reported in our study highlight the difficulties related to the implementation of SNL techniques in prostate cancer. There is controversy about how extensive lymph node dissection (LND) should be during prostatectomy. We investigated the lymphatic drainage of the prostate and whether sentinel node fluorescence techniques would be useful to detect node metastases. We found that the drainage pattern is complex and that the sentinel node technique is not able to replace extended pelvic LND. Copyright © 2016. Published by Elsevier B.V.
Clinical impact of sentinel lymph node biopsy in patients with thick (>4 mm) melanomas.
White, Ian; Fortino, Jeanine; Curti, Brendan; Vetto, John
2014-05-01
The role of sentinel lymph node status (SLNS) in thick melanoma is evolving. The purpose of this study was to determine the prognostic value of SLNS in thick melanoma. A retrospective analysis of 120 prospectively collected clinically node-negative thick melanomas over 5 years was performed. Patient (age/sex) and tumor (thickness, ulceration, SLNS, mitoses, metastases, and recurrence) features were collected. Multivariate analysis was performed using Cox proportional hazard model. Factors predictive of positive SLN included male sex, ulceration, and high mitoses. Factors associated with positive SLN had higher local-regional recurrence and metastases than negative SLN. SLNS and tumor thickness impacted 5-year disease-free survival (DFS) and overall survival (OS). Positive SLN, ulceration, age, and mitoses were independent predictors of DFS/OS. Nonulcerated/lower mitoses thick melanomas had lower positive SLN rates. Positive SLN develop recurrence and metastases and have worse OS/DFS. SLNS is an important prognosticator for OS/DFS. Sentinel lymph node biopsy delineates prognostic groups in thick melanomas and can impact management. Copyright © 2014 Elsevier Inc. All rights reserved.
Secondary node analysis as an indicator for axillary lymphadenectomy in breast cancer patients.
Cremades, Manel; Torres, Mireia; Solà, Montse; Navinés, Jordi; Pascual, Icíar; Mariscal, Antonio; Caballero, Albert; Castellà, Eva; Luna, Miguel Ángel; Julián, Joan Francesc
2017-11-01
Currently, there is no agreement regarding if it would be necessary to perform an axillary lymph node dissection (ALND) in patients who have macrometastases in the sentinel lymph node (SLN). We studied the utility of the secondary node analysis (SN), defined as the following node after the SLN in an anatomical and lymphatic pathway, as a sign of malignant axillary involvement. An observational, retrospective and multicentre study was designed to assess the utility of the SN as a sign of axillary involvement. Among 2273 patients with breast cancer, a valid sample of 283 was obtained representing those who had the SN studied. Main endpoints of our study were: the SLN, the SN and the ALND histological pattern. Sensitivity, specificity and precision of the test were also calculated. SN test, in cases with positive SLN, has a sensitivity of 61.1%, a specificity of 78.7%, a positive predictive value of 45.8% and a negative predictive value of 87.3% with a precision of 74.7%. The study of the SN together with the technique of the SLN allows a more precise staging of the axillary involvement, in patients with breast cancer, than just the SLN technique. Copyright © 2017 AEC. Publicado por Elsevier España, S.L.U. All rights reserved.
Fehr, Mathias K
2011-10-01
Sentinel lymph node (SLN) dissections have been shown to be sensitive for the evaluation of nodal basins for metastatic disease and are associated with decreased short-term and long-term morbidity when compared with complete lymph node dissection. There has been increasing interest in the use of SLN technology in gynecologic cancers. This review assesses the current evidence-based literature for the use of SLN dissections in gynecologic malignancies. Recent literature continues to support the safety and feasibility of SLN biopsy for early stage vulvar cancer with negative predictive value approaching 100 % and low false negative rates. Alternatively, for endometrial cancer most studies have reported low false-negative rates, with variable sensitivities and have reported low detection rates of the sentinel node. Studies examining the utility of SLN biopsy in early-stage cervical cancer remain promising with detection rates, sensitivities, and false-negative rates greater than 90 % for stage 1B1 tumors. SLN dissections have been shown to be effective and safe in certain, select vulvar cancer patients and can be considered an alternative surgical approach for these patients. For endometrial and cervical cancer, SLN dissection continues to have encouraging results and however needs further investigation.
Is a More Comprehensive Surgery Necessary in Patients With Uterine Serous Carcinoma?
Touhami, Omar; Trinh, Xuan-Bich; Gregoire, Jean; Sebastianelli, Alexandra; Renaud, Marie-Claude; Grondin, Katherine; Plante, Marie
2015-09-01
Uterine serous carcinoma (USC) is an aggressive histologic subtype of endometrial cancer that shares similarities to serous ovarian cancer, with a propensity for spread to the upper abdomen, a high recurrence rate, and a poor prognosis. The aim of this study was to determine whether the traditional surgical staging procedure for endometrial cancer was adequate for USC or whether a more extensive surgery, similar to the staging procedure for ovarian cancer, needs to be performed. Specifically, the roles of omentectomy and sentinel lymph node (SLN) mapping were evaluated. We retrospectively identified cases of presumed clinical stage I USC at our institution from April 2005 to March 2014. Medical records were reviewed for the following information: age at diagnosis, preoperative imaging, operative findings, surgical procedure, and final histology with definitive International Federation of Gynecology and Obstetrics stage. A total of 39 patients with presumed clinical stage I USC were identified. According to the final pathology report, the surgical stage was as follows: 17 stage IA (44%), 8 stage IB (20%), 3 stage II (8%), 2 stage IIIA (5%), 6 stage IIIC1 (15%), 1 IIIC2 (3%), and 2 stage IVB (5%). Therefore, 14 patients (36%) were surgically upstaged, but none of the patients had their clinical disease upstaged by virtue of finding microscopic metastatic disease in an otherwise normal-looking omentum. Sentinel lymph node mapping was performed in 19 patients (42%). Sensitivity and negative predictive value of SLN mapping were 100% when at least 1 SLN was identified. The detection of microscopic disease in radiologically and clinically normal-appearing omentum seems to be rare in USC. Sentinel lymph node mapping seems to be valuable in the serous subtype of endometrial cancer. A less extensive surgery may be possible in patients with USC as it seems to provide the same information as a more extensive surgery.
Sentinel Lymph Node (SLN) laparoscopic assessment early stage in endometrial cancer.
Gargiulo, T; Giusti, M; Bottero, A; Leo, L; Brokaj, L; Armellino, F; Palladin, L
2003-06-01
The aim of the study was to demonstrate the validity of sentinel lymph node (SLN) detection after injection of radioactive isotope and patent blue dye in patients affected by early stage endometrial cancer. The second purpose was to compare radioactive isotope and patent blue dye migration. Between September 2000 and May 2001, 11 patients with endometrial cancer FIGO stage Ib (n=10) and IIa (n=1) underwent laparoscopic SLN detection during laparoscopic assisted vaginal hysterectomy with bilateral salpingo-oophorectomy and pelvic bilateral systematic lymphadenectomy. Radioactive isotope injection was performed 24 ours before surgery and blue dye injection was performed just before surgery in the cervix at 3, 6, 9 and 12 hours. A 350 mm laparoscopic gamma-scintiprobe MR 100 type 11, (99m)Tc setted (Pol.Hi.Tech.), was used intraoperatively for detecting SLN. Seventeen SLN were detected at lymphoscintigraphy (6 bilateral and 5 monolateral). At laparoscopic surgery the same locations were found belonging at internal iliac lymph nodes (the so called "Leveuf-Godard" area, lateral to the inferior vescical artery, ventral to the origin of uterine artery and medial or caudal to the external iliac vein). Fourteen SLN were negative at histological analysis and only 3 positive for micrometastasis (mean SLN sections = 60. All the other pelvic lymph nodes were negative at histological analysis. The same SLN locations detected with g-scintiprobe were observed during laparoscopy after patent blue dye injection. If the sensitivity of the assessment of SLN is confirmed to be 100%, this laparoscopic approach could change the management of early stage endometrial cancer. The clinical validity of this technique must be evaluated prospectively.
Bennie, George; Vorster, Mariza; Buscombe, John; Sathekge, Mike
2015-01-01
Single-photon emission computed tomography-computed tomography (SPECT-CT) allows for physiological and anatomical co-registration in sentinel lymph node (SLN) mapping and offers additional benefits over conventional planar imaging. However, the clinical relevance when considering added costs and radiation burden of these reported benefits remains somewhat uncertain. This study aimed to evaluate the possible added value of SPECT-CT and intra-operative gamma-probe use over planar imaging alone in the South African setting. 80 patients with breast cancer or malignant melanoma underwent both planar and SPECT-CT imaging for SLN mapping. We assessed and compared the number of nodes detected on each study, false positive and negative findings, changes in surgical approach and or patient management. In all cases where a sentinel node was identified, SPECT-CT was more accurate anatomically. There was a significant change in surgical approach in 30 cases - breast cancer (n = 13; P 0.001) and malignant melanoma (n = 17; P 0.0002). In 4 cases a node not identified on planar imaging was seen on SPECT-CT. In 16 cases additional echelon nodes were identified. False positives were excluded by SPECT-CT in 12 cases. The addition of SPECT-CT and use of intra-operative gamma-probe to planar imaging offers important benefits in patients who present with breast cancer and melanoma. These benefits include increased nodal detection, elimination of false positives and negatives and improved anatomical localization that ultimately aids and expedites surgical management. This has been demonstrated in the context of industrialized country previously and has now also been confirmed in the setting of a emerging-market nation.
Jaukovic, Ljiljana; Rajović, Milica; Kandolf Sekulovic, Lidija; Radulovic, Marija; Stepic, Nenad; Mijuskovic, Zeljko; Petrov, Nenad; Ajdinovic, Boris
2018-05-14
Sentinel lymph node (SLN) biopsy is a widely accepted staging procedure for cutaneous melanoma patients who are at risk of clinically occult nodal metastases. Numerous predictive factors for regional lymph node metastases have been identified; however, few have been found to be reproducibly significant. Also, the role of blue dye in identification was questioned in recent trials. Time to procedure was also found to be predictive of SLN positivity, but this was not confirmed in other studies. In our study, predictive factors for metastatic involvement of SLN were analyzed, together with the role of addition blue dye in imaging on detection rate and false-negative SLN rate. An impact of time interval to procedure on the rate of SLN positivity was also explored. Data analysis was done in 362 cutaneous melanoma patients who underwent lymphoscintigraphy and SLN biopsy at our institution from 2010 to 2016, with a median follow-up of 29 months (1-98 months). To delineate the relation of each variable (demographical, time to procedure, and clinical and pathological variables, as well as the presence of in-transit nodes, the number of draining basins, and SLN localization on scintigraphy) with positive SLN status, we used univariate logistic regression with odds ratios representing effect size. Metastatic involvement SLN was found in 67 (18.8%) of 356 patients. Detection rate was similar with or without further intraoperative SLN identification with blue dye (98.8% vs 98.17%, P > 0.05). Time to procedure was not associated with higher SLN positivity rate (P > 0.05). In univariate analysis, Breslow thickness (P < 0.001), primary ulceration lesion (P = 0.001), and lymphovascular invasion (P = 0.006) were strongly correlated with SLN positivity, as well as the site of primary tumor (P = 0.024), tumor-infiltrating lymphocytes (TILs) (P = 0.021), and sex (P = 0.026). In multivariate analysis, Breslow thickness and TILs were found to be significant independent predictors of SLN status (P < 0.05). Addition of blue dye did not improve SLN detection rate; time to procedure was not found to be associated with higher SLN biopsy positivity rates. Breslow thickness and TILs, as a marker of immune response to tumor, were consistently found to be significant independent predictors of SLN status.
Franco, Renato; Cantile, Monica; Scala, Stefania; Catalano, Elisabetta; Cerrone, Margherita; Scognamiglio, Giosuè; Pinto, Antonio; Chiofalo, Maria Grazia; Caracò, Corrado; Anniciello, Anna Maria; Abbruzzese, Alberto; Caraglia, Michele; Botti, Gerardo
2010-03-15
Sentinel lymph node (SLN) biopsy is an important independent prognostic factor for invasive cutaneuos melanoma, although its role is strongly debated. In clinical practice SLN leads to complete lymph node dissection of basin draining melanoma site. However only 7-30% of positive sentinel node patients present additional non SLN metastasis. Melanoma cells diffusion through SLN and extranodal spreading depends upon biological features, such as cell chemokine receptors and adhesion molecules. CXCR4 has been proposed in melanoma patients as prognostic marker. Therefore we have analyzed both histopathological parameters and CXCR4 expression in melanoma infiltrate of SLN, in order to evaluate its potential prognostic role. Micrometastases were detected in 23 cases (48.93%); metastases >2 mm in 23 cases (48.93%) and isolated metastatic cells in one case (2.01%). High CXCR4 expression was observed in 21 nodal metastases. Node metastases in complete dissection were associated to >10% relative tumor area (RTA) in all lymph nodes (p = 0.006). Extranodal invasion (p = 0.006) and >2 mm centripetal metastasis thickness (p = 0.01), while shorter Disease Free Survival (DFS) was significantly associated to high CXCR4 expression (p = 0.02). Forty-seven positive lymph node metastases were collected and analysed for both histopathological parameters and CXCR4 expression. More than 10% RTA in SLN, extranodal invasion and centripetal metastasis thickness all predict additional lymph node metastases in melanoma site draining basins. Moreover, high CXCR4 expression is correlated to shorter DFS and could be used as a prognostic marker in order to stratify melanoma patients at higher progression risk.
Qin, Zhengtao; Hall, David J.; Liss, Michael A.; Hoh, Carl K.; Kane, Christopher J.; Wallace, Anne M.
2013-01-01
Abstract. The optical properties of a receptor-targeted probe designed for dual-modality mapping of the sentinel lymph node (SLN) was optimized. Specific fluorescence brightness was used as the design criterion, which was defined as the fluorescence brightness per mole of the contrast agent. Adjusting the molar ratio of the coupling reactants, IRDye 800CW-NHS-ester and tilmanocept, enabled us to control the number of fluorescent molecules attached to each tilmanocept, which was quantified by H1 nuclear magnetic resonance spectroscopy. Quantum yields and molar absorptivities were measured for unconjugated IRDye 800CW and IRDye 800CW-tilmanocept (800CW-tilmanocept) preparations at 0.7, 1.5, 2.3, 2.9, and 3.8 dyes per tilmanocept. Specific fluorescence brightness was calculated by multiplication of the quantum yield by the molar absorptivity and the number of dyes per tilmanocept. It predicted that the preparation with 2.3 dyes per tilmanocept would exhibit the brightest signal, which was confirmed by fluorescence intensity measurements using three optical imaging systems. When radiolabeled with Ga68 and injected into the footpads of mice, the probe identified SLNs by both fluorescence and positron emission tomography (PET) while maintaining high percent extraction by the SLN. These studies demonstrated the feasibility of 800CW-tilmanocept for multimodal SLN mapping via fluorescence and PET–computed tomography imaging. PMID:23958947
Wang, Xuejuan; Yang, Zhi; Lin, Baohe; Zhang, Yan; Zhai, Shizhen; Zhao, Qichao; Xie, Qing; Liu, Fei; Han, Xuedi; Li, Jinfeng; Ouyang, Tao
2016-06-21
We aimed to develop and translate a CD20-antigen-targeted radiopharmaceutical, Technetium-99 m-labeled (99mTc) rituximab, for sentinel lymph node (SLN) detection. 99mTc-rituximab was synthesized and tested for stability in human serum. The binding affinity to CD20 was evaluated in Raji cells by flow cytometric analysis. Biodistribution and sentinel node mapping were carried out in bal b/c mice. Eighty-five patients with breast cancer participated in this study. Dynamic sentinel lymphoscintigraphy was first assessed in 12 patients before planar lymphoscintigraphy was assessed in a larger cohort. All patients underwent sentinel lymph node biopsy (SLNB), followed by axillary lymph node dissection. The cell-binding study showed that 99mTc-rituximab possessed compatible affinity to human CD20. In the mechanism study, 99mTc-labeled anti-mouse CD20 monoclonal antibodies could bind to mouse CD20 and accumulate in the SLN with 2.62±1.25 % of the percentage of injected activity, which could be blocked by excessive unlabeled antibody. Low uptake of non-sentinel nodes and fast clearance from the injection site were observed in the mice. Sentinel nodes were identified in 82 of 85 breast cancer patients (96.5%) by lymphoscintigraphy and SLNB. The sensitivity, specificity, and accuracy were 96.8% (30/31), 100% (51/51), and 98.8% (81/82), respectively. 99mTc-rituximab, specifically binding to CD20, met most of the requirements of an ideal sentinel mapping agent for use in clinical settings.
Kang, Han Gyu; Lee, Ho-Young; Kim, Kyeong Min; Song, Seong-Hyun; Hong, Gun Chul; Hong, Seong Jong
2017-01-01
The aim of this study is to integrate NIR, gamma, and visible imaging tools into a single endoscopic system to overcome the limitation of NIR using gamma imaging and to demonstrate the feasibility of endoscopic NIR/gamma/visible fusion imaging for sentinel lymph node (SLN) mapping with a small animal. The endoscopic NIR/gamma/visible imaging system consists of a tungsten pinhole collimator, a plastic focusing lens, a BGO crystal (11 × 11 × 2 mm 3 ), a fiber-optic taper (front = 11 × 11 mm 2 , end = 4 × 4 mm 2 ), a 122-cm long endoscopic fiber bundle, an NIR emission filter, a relay lens, and a CCD camera. A custom-made Derenzo-like phantom filled with a mixture of 99m Tc and indocyanine green (ICG) was used to assess the spatial resolution of the NIR and gamma images. The ICG fluorophore was excited using a light-emitting diode (LED) with an excitation filter (723-758 nm), and the emitted fluorescence photons were detected with an emission filter (780-820 nm) for a duration of 100 ms. Subsequently, the 99m Tc distribution in the phantom was imaged for 3 min. The feasibility of in vivo SLN mapping with a mouse was investigated by injecting a mixture of 99m Tc-antimony sulfur colloid (12 MBq) and ICG (0.1 mL) into the right paw of the mouse (C57/B6) subcutaneously. After one hour, NIR, gamma, and visible images were acquired sequentially. Subsequently, the dissected SLN was imaged in the same way as the in vivo SLN mapping. The NIR, gamma, and visible images of the Derenzo-like phantom can be obtained with the proposed endoscopic imaging system. The NIR/gamma/visible fusion image of the SLN showed a good correlation among the NIR, gamma, and visible images both for the in vivo and ex vivo imaging. We demonstrated the feasibility of the integrated NIR/gamma/visible imaging system using a single endoscopic fiber bundle. In future, we plan to investigate miniaturization of the endoscope head and simultaneous NIR/gamma/visible imaging with dichroic mirrors and three CCD cameras. © 2016 American Association of Physicists in Medicine.
Simultaneous mapping of pan and sentinel lymph nodes for real-time image-guided surgery.
Ashitate, Yoshitomo; Hyun, Hoon; Kim, Soon Hee; Lee, Jeong Heon; Henary, Maged; Frangioni, John V; Choi, Hak Soo
2014-01-01
The resection of regional lymph nodes in the basin of a primary tumor is of paramount importance in surgical oncology. Although sentinel lymph node mapping is now the standard of care in breast cancer and melanoma, over 20% of patients require a completion lymphadenectomy. Yet, there is currently no technology available that can image all lymph nodes in the body in real time, or assess both the sentinel node and all nodes simultaneously. In this study, we report an optical fluorescence technology that is capable of simultaneous mapping of pan lymph nodes (PLNs) and sentinel lymph nodes (SLNs) in the same subject. We developed near-infrared fluorophores, which have fluorescence emission maxima either at 700 nm or at 800 nm. One was injected intravenously for identification of all regional lymph nodes in a basin, and the other was injected locally for identification of the SLN. Using the dual-channel FLARE intraoperative imaging system, we could identify and resect all PLNs and SLNs simultaneously. The technology we describe enables simultaneous, real-time visualization of both PLNs and SLNs in the same subject.
Chu, Maoquan; Hai, Wangxi; Zhang, Zheyu; Wo, Fangjie; Wu, Qiang; Zhang, Zefei; Shao, Yuxiang; Zhang, Ding; Jin, Lu; Shi, Donglu
2016-06-01
The use of non-toxic or low toxicity materials exhibiting dual functionality for use in sentinel lymph node (SLN) mapping and cancer therapy has attracted considerable attention during the past two decades. Herein, we report that the natural black sesame melanin (BSM) extracted from black sesame seeds (Sesamum indicum L.) shows exciting potential for SLN mapping and cancer photothermal therapy. Aqueous solutions of BSM under neutral and alkaline conditions can assemble into sheet-like nanoparticles ranging from 20 to 200 nm in size. The BSM nanoparticles were encapsulated by liposomes to improve their water solubility and the encapsulated and bare BSM nanoparticles were both non-toxic to cells. Furthermore, the liposome-encapsulated BSM nanoparticles (liposome-BSM) did not exhibit any long-term toxicity in mice. The liposome-BSM nanoparticles were subsequently used to passively target healthy and tumor-bearing mice SLNs, which were identified by the black color of the nanoparticles. BSM also strongly absorbed light in the near-infrared (NIR) range, which was rapidly converted to heat energy. Human esophagus carcinoma cells (Eca-109) were killed efficiently by liposome-BSM nanocomposites upon NIR laser irradiation. Furthermore, mouse tumor tissues grown from Eca-109 cells were seriously damaged by the photothermal effects of the liposome-BSM nanocomposites, with significant tumor growth suppression compared with controls. Given that BSM is a safe and nutritious biomaterial that can be easily obtained from black sesame seed, the results presented herein represent an important development in the use of natural biomaterials for clinical SLN mapping and cancer therapy. Copyright © 2016 Elsevier Ltd. All rights reserved.
Chen, Xue; He, Yingjian; Wang, Jiwei; Huo, Ling; Fan, Zhaoqing; Li, Jinfeng; Xie, Yuntao; Wang, Tianfeng; Ouyang, Tao
2018-06-14
Knowledge of the pathology of axillary lymph nodes (ALN) in breast cancer patients is critical for determining their treatment. Ultrasound is the best noninvasive evaluation for the ALN status. However, the correlation between negative ultrasound results and the sentinel lymph nodes (SLN) pathology remains unknown. To test the hypothesis that negative ultrasound results of ALN predict the negative pathology results of SLN in breast cancer patients, we assessed the association between ALN ultrasonography-negative results and the SLN pathology in 3115 patients with breast cancer recruited between October 2010 and April 2016 from a single cancer center, prospective database. Of these patients who met the inclusion criteria, 2317 (74.4%) had no SLN pathological metastasis. In the univariate analysis, other 798 patient with positive SLN tended to be under age 40 and premenopausal, having large tumor sizes (>2 cm), higher histological grade of primary tumor, positive hormone receptors, and negative HER-2 status (P < .05 for all). In the multivariate analysis, menstrual status, tumor size, ER status and histological types of primary tumor remained to be independent predictors for SLN pathological metastasis. The area under curve (AUC) was 0.658 (95% CI = 0.637-0.679), P > .05. In conclusion, only a 74.4% consistency between ALN ultrasonography-negative results and negative pathological SLN results, although menstrual status, tumor size, histologic subtypes of primary tumor and ER status were found to be statistically independent predictors of positive SLN among patients negative for ALN ultrasonography. Therefore, the present study suggests that negative ultrasound results of ALN do not adequately predict the negative pathology results of SLN in breast cancer patients. © 2018 The Authors. Cancer Medicine published by John Wiley & Sons Ltd.
Morais, Maurício; Campello, Maria P C; Xavier, Catarina; Heemskerk, Johannes; Correia, João D G; Lahoutte, Tony; Caveliers, Vicky; Hernot, Sophie; Santos, Isabel
2014-11-19
Current methods for sentinel lymph node (SLN) mapping involve the use of radioactivity detection with technetium-99m sulfur colloid and/or visually guided identification using a blue dye. To overcome the kinetic variations of two individual imaging agents through the lymphatic system, we report herein on two multifunctional macromolecules, 5a and 6a, that contain a radionuclide ((99m)Tc or (68)Ga) and a near-infrared (NIR) reporter for pre- and/or intraoperative SLN mapping by nuclear and NIR optical imaging techniques. Both bimodal probes are dextran-based polymers (10 kDa) functionalized with pyrazole-diamine (Pz) or 1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid (DOTA) chelating units for labeling with fac-[(99m)Tc(CO)3](+) or (68)Ga(III), respectively, mannose units for receptor targeting, and NIR fluorophore units for optical imaging. The probes allowed a clear visualization of the popliteal node by single-photon emission computed tomography (SPECT/CT) or positron emission tomography (PET/CT), as well as real-time optically guided excision. Biodistribution studies confirmed that both macromolecules present a significant accumulation in the popliteal node (5a: 3.87 ± 0.63% IA/organ; 6a: 1.04 ± 0.26% IA/organ), with minimal spread to other organs. The multifunctional nanoplatforms display a popliteal extraction efficiency >90%, highlighting their potential to be further explored as dual imaging agents.
The prognostic significance of nonsentinel lymph node metastasis in melanoma.
Brown, Russell E; Ross, Merrick I; Edwards, Michael J; Noyes, R Dirk; Reintgen, Douglas S; Hagendoorn, Lee J; Stromberg, Arnold J; Martin, Robert C G; McMasters, Kelly M; Scoggins, Charles R
2010-12-01
We hypothesized that metastasis beyond the sentinel lymph nodes (SLN) to the nonsentinel nodes (NSN) is an important predictor of survival. Analysis was performed of a prospective multi-institutional study that included patients with melanoma ≥ 1.0 mm in Breslow thickness. All patients underwent SLN biopsy; completion lymphadenectomy was performed for all SLN metastases. Disease-free survival (DFS) and overall survival (OS) were computed by Kaplan-Meier analysis; univariate and multivariate analyses were performed to identify factors associated with differences in survival among groups. A total of 2335 patients were analyzed over a median follow-up of 68 months. We compared 3 groups: SLN negative (n = 1988), SLN-only positive (n = 296), and both SLN and NSN positive (n = 51). The 5-year DFS rates were 85.5, 64.8, and 42.6% for groups 1, 2, and 3, respectively (P < 0.001). The 5-year OS rates were 85.5, 64.9, and 49.4%, respectively (P < 0.001). On univariate analysis, predictors of decreased OS included: SLN metastasis, NSN metastasis, increased total number of positive LN, increased ratio of positive LN to total LN, increased age, male gender, increased Breslow thickness, presence of ulceration, Clark level ≥ IV, and axial primary site (in all cases, P < 0.01). When the total number of positive LN and NSN status were evaluated using multivariate analysis, NSN status remained statistically significant (P < 0.01), while the total number of positive LN and LN ratio did not. NSN melanoma metastasis is an independent prognostic factor for DFS and OS, which is distinct from the number of positive lymph nodes or the lymph node ratio.
Niki, Yuichiro; Ogawa, Mikako; Makiura, Rie; Magata, Yasuhiro; Kojima, Chie
2015-11-01
The detection of the sentinel lymph node (SLN), the first lymph node draining tumor cells, is important in cancer diagnosis and therapy. Dendrimers are synthetic macromolecules with highly controllable structures, and are potent multifunctional imaging agents. In this study, 12 types of dendrimer of different generations (G2, G4, G6, and G8) and different terminal groups (amino, carboxyl, and acetyl) were prepared to determine the optimal dendrimer structure for SLN imaging. Radiolabeled dendrimers were intradermally administrated to the right footpads of rats. All G2 dendrimers were predominantly accumulated in the kidney. Amino-terminal, acetyl-terminal, and carboxyl-terminal dendrimers of greater than G4 were mostly located at the injection site, in the blood, and in the SLN, respectively. The carboxyl-terminal dendrimers were largely unrecognized by macrophages and T-cells in the SLN. Finally, SLN detection was successfully performed by single photon emission computed tomography imaging using carboxyl-terminal dendrimers of greater than G4. The early detection of tumor cells in the sentinel draining lymph nodes (SLN) is of utmost importance in terms of determining cancer prognosis and devising treatment. In this article, the authors investigated various formulations of dendrimers to determine the optimal one for tumor detection. The data generated from this study would help clinicians to fight the cancer battle in the near future. Copyright © 2015 Elsevier Inc. All rights reserved.
Sentinel lymph node biopsy in gastrointestinal malignancies-where do we stand?
Maharaj, R; Shukla, P J; Naraynsingh, V; Dan, D; Hariharan, S
2011-01-01
Sentinel lymph nodes (SLNs) are the nodes in direct communication with the primary tumor and are therefore the first group of nodes to be involved in lymphatic metastasis. Though the role of SLN biopsy is well established in cancers of the breast and melanoma, its role in gastrointestinal malignancies is still evolving and controversial. In this paper, the literature is reviewed with respect to the status of SLN biopsy in gastrointestinal malignancies.
Niikura, Hitoshi; Kaiho-Sakuma, Michiko; Tokunaga, Hideki; Toyoshima, Masafumi; Utsunomiya, Hiroki; Nagase, Satoru; Takano, Tadao; Watanabe, Mika; Ito, Kiyoshi; Yaegashi, Nobuo
2013-11-01
The aim of the present study was to clarify the most effective combination of injected tracer types and injection sites in order to detect sentinel lymph nodes (SLNs) in early endometrial cancer. The study included 100 consecutive patients with endometrial cancer treated at Tohoku University Hospital between June 2001 and December 2012. The procedure for SLN identification entailed either radioisotope (RI) injection into the endometrium during hysteroscopy (55 cases) or direct RI injection into the uterine cervix (45 cases). A combination of blue dye injected into the uterine cervix or uterine body intraoperatively in addition to preoperative RI injection occurred in 69 of 100 cases. All detected SLNs were recorded according to the individual tracer and the resultant staging from this method was compared to the final pathology of lymph node metastases including para-aortic nodes. SLN detection rate was highest (96%) by cervical RI injection; however, no SLNs were detected in para-aortic area. Para-aortic SLNs were detected only by hysteroscopic RI injection (56%). All cases with pelvic lymph node metastases were detected by pelvic SLN biopsy. Isolated positive para-aortic lymph nodes were detected in 3 patients. Bilateral SLN detection rate was high (96%; 26 of 27 cases) by cervical RI injection combined with dye. RI injection into the uterine cervix is highly sensitive in detection of SLN metastasis in early stage endometrial cancer. It is a useful and safe modality when combined with blue dye injection into the uterine body. © 2013.
Mieog, J Sven D; Troyan, Susan L; Hutteman, Merlijn; Donohoe, Kevin J; van der Vorst, Joost R; Stockdale, Alan; Liefers, Gerrit-Jan; Choi, Hak Soo; Gibbs-Strauss, Summer L; Putter, Hein; Gioux, Sylvain; Kuppen, Peter J K; Ashitate, Yoshitomo; Löwik, Clemens W G M; Smit, Vincent T H B M; Oketokoun, Rafiou; Ngo, Long H; van de Velde, Cornelis J H; Frangioni, John V; Vahrmeijer, Alexander L
2011-09-01
Near-infrared (NIR) fluorescent sentinel lymph node (SLN) mapping in breast cancer requires optimized imaging systems and lymphatic tracers. A small, portable version of the FLARE imaging system, termed Mini-FLARE, was developed for capturing color video and two semi-independent channels of NIR fluorescence (700 and 800 nm) in real time. Initial optimization of lymphatic tracer dose was performed using 35-kg Yorkshire pigs and a 6-patient pilot clinical trial. More refined optimization was performed in 24 consecutive breast cancer patients. All patients received the standard of care using (99m)Technetium-nanocolloid and patent blue. In addition, 1.6 ml of indocyanine green adsorbed to human serum albumin (ICG:HSA) was injected directly after patent blue at the same location. Patients were allocated to 1 of 8 escalating ICG:HSA concentration groups from 50 to 1000 μM. The Mini-FLARE system was positioned easily in the operating room and could be used up to 13 in. from the patient. Mini-FLARE enabled visualization of lymphatic channels and SLNs in all patients. A total of 35 SLNs (mean = 1.45, range 1-3) were detected: 35 radioactive (100%), 30 blue (86%), and 35 NIR fluorescent (100%). Contrast agent quenching at the injection site and dilution within lymphatic channels were major contributors to signal strength of the SLN. Optimal injection dose of ICG:HSA ranged between 400 and 800 μM. No adverse reactions were observed. We describe the clinical translation of a new NIR fluorescence imaging system and define the optimal ICG:HSA dose range for SLN mapping in breast cancer.
Sentinel lymph node detection in patients with early cervical cancer.
Acharya, B C; Jihong, L
2009-01-01
Lymph node status is the most important independent prognostic factor in early stage cervical cancer. Intraoperative lymphatic mapping and sentinel lymph node detection have been increasingly evaluated in the treatment of a variety of solid tumors, particularly breast cancer and cutaneous melanoma. This study evaluated the feasibility of these procedures in patients undergoing radical hysterectomy with pelvic lymphadenectomy for early cervical cancer. A total of 30 patients with histologically diagnosed FIGO stage IA to IIA cervical cancer were enrolled to this study. They were scheduled to undergo radical abdominal hysterectomy and pelvic lymphadenectomy after injecting patent blue dye in cervix. A total of 60 SLNs (mean 2.5) were detected in 24 patients with detection rate of 80%. Bilateral SLNs were detected in 70.1% of cases. SLNs were identified in obturator and external iliac areas in 50% and 31.7%, respectively; no SLNs were discovered in the common iliac region. Seven patients (23.3%) had lymph node metastases; one of these had false negative SLN.The false negative rate and negative predictive value were 14.3% and 94.4%, respectively. SLN detection procedure with blue dye technique is a feasible procedure in cervical cancer. Patent blue dye is cheap, safe and effective tracer to detect sentinel node in carcinoma of cervix.
Andreis, D; Bonardi, S; Allevi, G; Aguggini, S; Gussago, F; Milani, M; Strina, C; Spada, D; Ferrero, G; Ungari, M; Rocca, A; Nanni, O; Roviello, G; Berruti, A; Harris, A L; Fox, S B; Roviello, F; Polom, K; Bottini, A; Generali, D
2016-10-01
Histological status of axillary lymph nodes is an important prognostic factor in patients receiving surgery for breast cancer (BC). Sentinel lymph node (SLN) biopsy (B) has rapidly replaced axillary lymph node dissection (ALND), and is now the standard of care for axillary staging in patients with clinically node-negative (N0) operable BC. The aim of this study is to compare pretreatment lymphoscintigraphy with a post primary systemic treatment (PST) scan in order to reduce the false-negative rates for SLNB. In this single-institution study we considered 170 consecutive T2-4 N0-1 M0 BC patients treated with anthracycline-based PST. At the time of incisional biopsy, we performed sentinel lymphatic mapping. After PST, all patients repeated lymphoscintigraphy with the same methodology. During definitive surgery we performed further sentinel lymphatic mapping, SLNB and ALND. The SLN was removed in 158/170 patients giving an identification rate of 92.9% (95% confidence interval (CI) = 88.0-96.3%) and a false-negative rate of 14.0% (95% CI = 6.3-25.8%). SLNB revealed a sensitivity of 86.0% (95% CI = 74.2-93.7%), an accuracy of 94.9% (95% CI = 90.3-97.8%) and a negative predictive value of 92.7% (95% CI = 86.1-96.8%). Identification rate, sensitivity and accuracy are in accordance with other studies on SLNB after PST, even after clinically negative node conversion following PST. This study confirms that diagnostic biopsy and neoadjuvant chemotherapy maintain breast lymphatic drainage unaltered. Copyright © 2016 Elsevier Ltd. All rights reserved.
Intraoperative imprint cytology for evaluation of sentinel lymph nodes from visceral malignancies.
Levine, Edward A; Shen, Perry; Shiver, Stephen A; Waters, Gregory; Brant, Andrew; Geisenger, Kim R
2003-01-01
Although originally described for breast cancer and melanoma, sentinel lymph node (SLN) mapping techniques are being investigated in the treatment of visceral malignancies. There is no literature evaluating intraoperative analysis of SLNs from visceral sites. We evaluated the utility of touch preparation intraoperative imprint cytology (IIC) in evaluating SLNs harvested in the setting of visceral malignancy. SLN mapping procedures involving 50 cases of visceral malignancy (37 colon, 12 gastric, and 1 small bowel), from February 1999 through August 2001, were studied. In each case, subserosal injections of isosulfan blue were used to identify the SLN. The SLNs were then sent fresh to the pathology laboratory for evaluation by IIC. A standard lymphadenectomy was performed in all cases. Postoperatively, the SLNs were evaluated by means of using hematoxylin and eosin staining. If these stains were normal, immunohistochemical analyses using carcinoembryonic antigen and cytokeratin were subsequently performed. SLNs were successfully identified in 46 cases (92%), and a total of 95 SLNs were harvested. The average number of SLNs was 1.9 with a range of one to six. More SLNs were found with gastric than with colonic lesions (2.8 vs. 1.8; P=.017). Evaluable IIC in 41 cases revealed metastatic disease in 10 SLNs, representing seven patients. Of the 34 patients with normal IIC, five were found to have positive SLNs on hematoxylin and eosin staining. An additional three patients were found to have positive SLNs only on immunohistochemical analysis. The overall sensitivity and specificity of IIC was 64% and 100%, respectively. This resulted in a positive predictive value of 100% and a negative predictive value of 86%. The use of IIC to evaluate SLNs from visceral malignancies is clearly feasible. When the IIC of the SLN is positive, the surgeon may feel confident that disease is actually present in the SLN. If there is a negative result, the technique may miss disease that is present on subsequent permanent sections. We do not recommend routine use of IIC; however, it may be of use in clinical trials.
Cusimano, Maria C; Walker, Rachel; Bernardini, Marcus Q; Bouchard-Fortier, Geneviève; Laframboise, Stephane; May, Taymaa; Murphy, Joan; Rosen, Barry; Covens, Al; Clarke, Blaise; Shaw, Patricia; Rouzbahman, Marjan; Mohan, Ravi; Ferguson, Sarah E
2017-08-01
Sentinel lymph node (SLN) biopsy is becoming a reasonable alternative to pelvic lymphadenectomy in early-stage cervical cancer. It is therefore imperative that centres without prior experience are able to successfully implement the procedure. The objectives of the current study were to (1) describe the process of implementing an SLN biopsy program with a novel peer mentorship component and (2) assess post-program quality improvement metrics, including SLN detection rate (DR) and diagnostic parameters. An institutional SLN biopsy protocol was developed collaboratively by gynaecologic oncology, nuclear medicine, and pathology departments at University Health Network, Toronto, Ontario. All decisions were based on the best evidence available. Newly diagnosed, early-stage cervical cancer patients undergoing primary surgery were then recruited prospectively for SLN biopsy with combined technique, followed by pelvic lymphadenectomy to evaluate key quality indicators, including SLN DR, sensitivity, and negative predictive value. Surgeons with previous SLN biopsy experience mentored surgeons unfamiliar with the technique. Interim analyses and multidisciplinary rounds were regularly carried out to identify failures of technique or protocol. Thirty-nine patients (median age 42) were enrolled in the study between August 2010 and February 2014. The median number of SLNs and total pelvic lymph nodes removed per patient were 3 and 19, respectively. SLN DRs were 92% per patient (36/39), 88.5% per hemipelvis (69/78), and 85% bilaterally (33/39). SLN biopsy correctly identified seven of eight hemipelvises with nodal metastases, yielding a sensitivity of 88% (95% CI 0.47 to 1.00) and a false negative rate of 12% (95% CI 0 to 0.53). Surgeons undergoing peer mentorship (n = 3) performed as effectively (DR 100%) as surgeons (n = 2) with prior experience (DR 85%). This study provides a model upon which other centres can adopt and validate cervical SLN biopsy. High SLN DRs and accurate identification of lymph node metastases can be achieved by focusing on multidisciplinary collaboration, knowledge translation with creation of evidence-based protocols, peer mentorship, and ongoing quality control. Copyright © 2017 The Society of Obstetricians and Gynaecologists of Canada/La Société des obstétriciens et gynécologues du Canada. Published by Elsevier Inc. All rights reserved.
Chi, Chongwei; Ye, Jinzuo; Ding, Haolong; He, De; Huang, Wenhe; Zhang, Guo-Jun; Tian, Jie
2013-01-01
Assessment of the sentinel lymph node (SLN) in patients with early stage breast cancer is vital in selecting the appropriate surgical approach. However, the existing methods, including methylene blue and nuclides, possess low efficiency and effectiveness in mapping SLNs, and to a certain extent exert side effects during application. Indocyanine green (ICG), as a fluorescent dye, has been proved reliable usage in SLN detection by several other groups. In this paper, we introduce a novel surgical navigation system to detect SLN with ICG. This system contains two charge-coupled devices (CCD) to simultaneously capture real-time color and fluorescent video images through two different bands. During surgery, surgeons only need to follow the fluorescence display. In addition, the system saves data automatically during surgery enabling surgeons to find the registration point easily according to image recognition algorithms. To test our system, 5 mice and 10 rabbits were used for the preclinical setting and 22 breast cancer patients were utilized for the clinical evaluation in our experiments. The detection rate was 100% and an average of 2.7 SLNs was found in 22 patients. Our results show that the usage of our surgical navigation system with ICG to detect SLNs in breast cancer patients is technically feasible. PMID:24358319
Krag, David N; Anderson, Stewart J; Julian, Thomas B; Brown, Ann M; Harlow, Seth P; Costantino, Joseph P; Ashikaga, Takamaru; Weaver, Donald L; Mamounas, Eleftherios P; Jalovec, Lynne M; Frazier, Thomas G; Noyes, R Dirk; Robidoux, André; Scarth, Hugh Mc; Wolmark, Norman
2010-10-01
Sentinel-lymph-node (SLN) surgery was designed to minimise the side-effects of lymph-node surgery but still offer outcomes equivalent to axillary-lymph-node dissection (ALND). The aims of National Surgical Adjuvant Breast and Bowel Project (NSABP) trial B-32 were to establish whether SLN resection in patients with breast cancer achieves the same survival and regional control as ALND, but with fewer side-effects. NSABP B-32 was a randomised controlled phase 3 trial done at 80 centres in Canada and the USA between May 1, 1999, and Feb 29, 2004. Women with invasive breast cancer were randomly assigned to either SLN resection plus ALND (group 1) or to SLN resection alone with ALND only if the SLNs were positive (group 2). Random assignment was done at the NSABP Biostatistical Center (Pittsburgh, PA, USA) with a biased coin minimisation approach in an allocation ratio of 1:1. Stratification variables were age at entry (≤ 49 years, ≥ 50 years), clinical tumour size (≤ 2·0 cm, 2·1-4·0 cm, ≥ 4·1 cm), and surgical plan (lumpectomy, mastectomy). SLN resection was done with a blue dye and radioactive tracer. Outcome analyses were done in patients who were assessed as having pathologically negative sentinel nodes and for whom follow-up data were available. The primary endpoint was overall survival. Analyses were done on an intention-to-treat basis. All deaths, irrespective of cause, were included. The mean time on study for the SLN-negative patients with follow-up information was 95·6 months (range 70·1-126·7). This study is registered with ClinicalTrials.gov, number NCT00003830. 5611 women were randomly assigned to the treatment groups, 3989 had pathologically negative SLN. 309 deaths were reported in the 3986 SLN-negative patients with follow-up information: 140 of 1975 patients in group 1 and 169 of 2011 in group 2. Log-rank comparison of overall survival in groups 1 and 2 yielded an unadjusted hazard ratio (HR) of 1·20 (95% CI 0·96-1·50; p=0·12). 8-year Kaplan-Meier estimates for overall survival were 91·8% (95% CI 90·4-93·3) in group 1 and 90·3% (88·8-91·8) in group 2. Treatment comparisons for disease-free survival yielded an unadjusted HR of 1·05 (95% CI 0·90-1·22; p=0·54). 8-year Kaplan-Meier estimates for disease-free survival were 82·4% (80·5-84·4) in group 1 and 81·5% (79·6-83·4) in group 2. There were eight regional-node recurrences as first events in group 1 and 14 in group 2 (p=0·22). Patients are continuing follow-up for longer-term assessment of survival and regional control. The most common adverse events were allergic reactions, mostly related to the administration of the blue dye. Overall survival, disease-free survival, and regional control were statistically equivalent between groups. When the SLN is negative, SLN surgery alone with no further ALND is an appropriate, safe, and effective therapy for breast cancer patients with clinically negative lymph nodes. US Public Health Service, National Cancer Institute, and Department of Health and Human Services. Copyright © 2010 Elsevier Ltd. All rights reserved.
Mokhtar, Mohamed; Tadokoro, Yukiko; Nakagawa, Misako; Morimoto, Masami; Takechi, Hirokazu; Kondo, Kazuya; Tangoku, Akira
2016-03-01
Sentinel lymph node biopsy (SLNB) became a standard surgical procedure for patients with early breast cancer; however, the optimal method of sentinel lymph node (SLN) identification remains controversial. The current study presents the protocol of our institution for preoperative and intraoperative SLN detection. Fifty female patients with early breast cancer and clinically node-negative axilla were enrolled in this study. All patients underwent preoperative CT lymphography (CTLG), intraoperative SLNB using fluorescence navigation, intraoperative one-step nucleic acid amplification (OSNA) and postoperative hematoxylin and eosin histopathological analysis. Prediction of metastasis by CTLG and detection of metastasis by OSNA were compared to results of histopathology as standard reference. SLN were identified by preoperative CTLG and intraoperative SLNB with fluorescence navigation in all patients, the identification rate was 100 %. SLN metastases were detected as positive by OSNA in 9 patients (18 %), 4 were (++), 4 were (+) and 1 was (+I). SLN metastases were detected as positive by histopathology in 10 patients (20 %). The concordance rate between OSNA and permanent sections was 90 %. The negative predictive value of CTLG was 80 %. Use of CTLG and fluorescence navigation made performing SLNB with high accuracy possible in institutions that cannot use the radioisotope method. OSNA provided accurate intraoperative method, allowing for completion of axillary node dissection during surgery and avoidance of second surgical procedure in patients with positive SLNs, thereby reducing patient distress and, finally, saving hospital costs.
Evaluation of Breast Sentinel Lymph Node Coverage by Standard Radiation Therapy Fields
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rabinovitch, Rachel; Ballonoff, Ari; Newman, Francis M.S.
2008-04-01
Background: Biopsy of the breast sentinel lymph node (SLN) is now a standard staging procedure for early-stage invasive breast cancer. The anatomic location of the breast SLN and its relationship to standard radiation fields has not been described. Methods and Materials: A retrospective review of radiotherapy treatment planning data sets was performed in patients with breast cancer who had undergone SLN biopsy, and those with a surgical clip at the SLN biopsy site were identified. The location of the clip was evaluated relative to vertebral body level on an anterior-posterior digitally reconstructed radiograph, treated whole-breast tangential radiation fields, and standardmore » axillary fields in 106 data sets meeting these criteria. Results: The breast SLN varied in vertebral body level position, ranging from T2 to T7 but most commonly opposite T4. The SLN clip was located below the base of the clavicle in 90%, and hence would be excluded from standard axillary radiotherapy fields where the inferior border is placed at this level. The clip was within the irradiated whole-breast tangent fields in 78%, beneath the superior-posterior corner multileaf collimators in 12%, and outside the tangent field borders in 10%. Conclusions: Standard axillary fields do not encompass the lymph nodes at highest risk of containing tumor in breast cancer patients. Elimination of the superior-posterior corner MLCs from the tangent field design would result in inclusion of the breast SLN in 90% of patients treated with standard whole-breast irradiation.« less
Boada, Aram; Tejera-Vaquerizo, Antonio; Ribero, Simone; Puig, Susana; Moreno-Ramírez, David; Descalzo-Gallego, Miguel A; Fierro, María T; Quaglino, Pietro; Carrera, Cristina; Malvehy, Josep; Vidal-Sicart, Sergi; Bennássar, Antoni; Rull, Ramón; Alos, Llucìa; Requena, Celia; Bolumar, Isidro; Traves, Víctor; Pla, Ángel; Fernández-Figueras, María T; Ferrándiz, Carlos; Pascual, Iciar; Manzano, José L; Sánchez-Lucas, Marina; Giménez-Xavier, Pol; Ferrandiz, Lara; Nagore, Eduardo
2018-02-01
The clinical value of sentinel lymph node (SLN) biopsy in thick melanoma patients (Breslow >4 mm) has not been sufficiently studied. The aim of the study is to evaluate whether SLN biopsy increases survival in patients with thick cutaneous melanoma, and, as a secondary objective, to investigate correlations between survival and lymph node status. We included 1,211 consecutive patients with thick melanomas (>4 mm) registered in the participating hospitals' melanoma databases between 1997 and 2015. Median follow-up was 40 months. Of these patients, 752 were matched into pairs by propensity scores based on sex, age, tumor location, histologic features of melanoma, year of diagnosis, hospital and adjuvant interferon therapy. The SLN biopsy vs. observation was associated with better DFS [adjusted hazard ratio (AHR), 0.74; 95% confidence interval (CI) 0.61-0.90); p = 0.002] and OS (AHR, 0.75; 95% CI, 0.60-0.94; p = 0.013) but not MSS (AHR, 0.84; 95% CI, 0.65-1.08; p = 0.165). SLN-negative patients had better 5- and 10-year MSS compared with SLN-positive patients (65.4 vs. 51.9% and 48.3 vs. 38.8%; p = 0.01, respectively). As a conclusion, SLN biopsy was associated with better DFS but not MSS in thick melanoma patients after adjustment for classic prognostic factors. SLN biopsy is useful for stratifying these patients into different prognostic groups. © 2017 UICC.
Maccauro, Marco; Lucignani, Giovanni; Aliberti, Gianluca; Villano, Carlo; Castellani, Maria Rita; Solima, Eugenio; Bombardieri, Emilio
2005-05-01
The purpose of this study was to assess the feasibility of sentinel lymph node (SLN) detection in endometrial cancer patients with a dual-tracer procedure after hysteroscopic peritumoural injection. Twenty-six women with previously untreated endometrial adenocarcinoma underwent the hysteroscopic injection of 111 MBq 99mTc-Nanocoll and blue dye administered subendometrially around the lesion. On the same day, all 26 patients underwent lymphoscintigraphy, followed 3-4 h later by hysterotomy with bilateral salpingo-oophorectomy and pelvic lymphadenectomy. Para-aortic lymphadenectomy was also performed in cases of either serous or papillary carcinoma (n=7/26). All SLNs were removed and examined with haematoxylin and eosin staining and immunohistochemical techniques. The procedure was well tolerated by patients, only two experiencing transient vagal symptoms. The sensitivity of this technique for correct identification of SLNs was 100%. Lymph node metastases were found in 4 out of the 26 patients (15%), bilaterally in the external iliac region (n=1), unilaterally in the external iliac region (n=1), unilaterally in the common iliac region (n=1) and unilaterally in the para-aortic region (n=1). In all four cases, nodal metastases were located within SLNs detected by lymphoscintigraphy. Only 10 of the 26 patients (38%) had significant blue dye staining. All blue-stained SLNs were radioactive. In patients with endometrial cancer, it is feasible to use lymphatic mapping and SLN biopsy to define the topographic distribution of the lymphatic network and also to accurately detect lumbo-aortic and pelvic metastases within SLNs. In the majority of patients with early stage endometrial cancer, this procedure may avoid unnecessary radical pelvic lymphadenectomy. It may also guide para-aortic lymph node dissection on the basis of the SLN status.
The Prognostic Significance of Sentinel Lymph Node Status for Patients with Thick Melanoma.
Bello, Danielle M; Han, Gang; Jackson, Laura; Bulloch, Kaleigh; Ariyan, Stephan; Narayan, Deepak; Rothberg, Bonnie Gould; Han, Dale
2016-12-01
Sentinel lymph node biopsy (SLNB) is recommended for patients with intermediate-thickness melanoma, but the use of SLNB for patients with thick melanoma is debated. This report presents a single-institution study investigating factors predictive of sentinel lymph node (SLN) metastasis and outcome for thick-melanoma patients . A retrospective review of a single-institution database from 1997 to 2012 identified 147 patients with thick primary cutaneous melanoma (≥4 mm) who had an SLNB. Clinicopathologic characteristics were correlated with nodal status and outcome. The median age of the patients was 67 years, and 61.9 % of the patients were men. The median tumor thickness was 5.5 mm, and 54 patients (36.7 %) had a positive SLN. Multivariable analysis showed that only tumor thickness significantly predicted SLN metastasis (odds ratio 1.14; 95 % confidence interval (CI) 1.02-1.28; P = 0.02). The overall median follow-up period was 34.6 months. Overall survival (OS) and melanoma-specific survival (MSS) were significantly worse for the positive versus negative-SLN patients. Multivariable analysis showed that age [hazard ratio (HR) 1.04; 95 % CI 1.01-1.07; P = 0.02] and SLN status (HR 2.24; 95 % CI 1.03-4.88; P = 0.04) significantly predicted OS, whereas only SLN status (HR 3.85; 95 % CI 2.13-6.97; P < 0.01) significantly predicted MSS. Tumor thickness predicts SLN status in thick melanomas. Furthermore, SLN status is prognostic for OS and MSS in thick-melanoma patients, with positive-SLN patients having significantly worse OS and MSS. These findings show that SLNB should be recommended for thick-melanoma patients, particularly because detection of SLN metastasis can identify patients for potential systemic therapy and treatment of nodal disease at a microscopic stage.
Murphy, Brittany L; Glasgow, Amy E; Keeney, Gary L; Habermann, Elizabeth B; Boughey, Judy C
2017-10-01
Routine sentinel lymph node (SLN) surgery during prophylactic mastectomy (PM) is unnecessary, because most PMs do not contain cancer. Our institution utilizes intraoperative pathology to guide the surgical decision for resection of SLNs in PM. The purpose of this study was to review the effectiveness of this approach. We identified all women aged ≥18 years who underwent bilateral PM (BPM) or contralateral PM (CPM) at our institution from January 2008 to July 2016. We evaluated the frequency of SLN resection and rate of occult breast cancer (DCIS or invasive disease) in the PM. We used the following definitions: over-treatment-SLN surgery in patients without cancer; under-treatment-no SLN surgery in patients with cancer; appropriate treatment-no SLN in patients without cancer or SLN surgery in patients with cancer. PM was performed on 1900 breasts: 1410 (74.2%) CPMs and 490 (25.8%) BPMs. Cancer was identified in 58 (3.0%) cases (32 invasive disease and 26 DCIS) and concurrent SLN surgery was performed in 44 (75.9%) of those cases. Overall, SLN surgery guided by intraoperative pathology resulted in appropriate treatment of 1787 (94.1%) cases: 1319 (93.5%) CPMs and 468 (95.5%) BPMs, by avoiding SLN in 1743/1842 cases without cancer (94.6%), and performing SLN surgery in 44/58 cases with cancer (75.9%). Use of intraoperative pathology to direct SLN surgery in patients undergoing PM minimizes over-treatment from routine SLN in PM and minimizes under-treatment from avoiding SLN in PM, demonstrating the value of intraoperative pathology in this era of focus on appropriateness of care.
Gap-enhanced Raman tags for high-contrast sentinel lymph node imaging.
Bao, Zhouzhou; Zhang, Yuqing; Tan, Ziyang; Yin, Xia; Di, Wen; Ye, Jian
2018-05-01
The sentinel lymph node (SLN) biopsy is gaining in popularity as a procedure to investigate the lymphatic metastasis of malignant tumors. The commonly used techniques to identify the SLNs in clinical practice are blue dyes-guided visualization, radioisotope-based detection and near-infrared fluorescence imaging. However, all these methods have not been found to perfectly fit the clinical criteria with issues such as short retention time in SLN, poor spatial resolution, autofluorescence, low photostability and high cost. In this study, we have reported a new type of nanoprobes, named, gap-enhanced Raman tags (GERTs) for the SLN Raman imaging. With the advantageous features including unique "fingerprint" Raman signal, strong Raman enhancement, high photostability, good biocompatibility and extra-long retention time, we have demonstrated that GERTs are greatly favorable for high-contrast and deep SLN Raman imaging, which meanwhile reveals the dynamic migration behavior of the probes entering the SLN. In addition, a quantitative volumetric Raman imaging (qVRI) data-processing method is employed to acquire a high-resolution 3-dimensional (3D) margin of SLN as well as the content variation of GERTs in the SLN. Moreover, SLN detection could be realized via a cost-effective commercial portable Raman scanner. Therefore, GERTs hold the great potential to be translated in clinical application for accurate and intraoperative location of the SLN. Copyright © 2018 Elsevier Ltd. All rights reserved.
Wuntakal, Rekha; Papadopoulos, Andreas John; Montalto, Stephen Attard; Perovic, Milica; Coutts, Michael; Devaja, Omer
2015-11-01
The aims of this study were to assess locality of the sentinel lymph node (SLN) in cervical carcinoma and examine factors affecting bilateral SLN detection. This was a retrospective review of SLN data (anatomical location, count and laterality) in patients with early-stage cervical cancer (International Federation of Gynecology and Obstetrics stage IA1 with lymphovascular space invasion to stage IIA) using intraoperative gamma probe and blue dye. The preoperative single-photon emission computed tomography with computed tomography was used to detect laterality, number of the SLNs, and rare locations. Patients were treated between January 2005 to January 2015 at the West Kent Gynaecological Oncology Centre, Maidstone Hospital, Maidstone, United Kingdom. A total of 132 women were investigated. The most common SLN location was the external iliac (38.6%) followed by obturator (25.3%) and internal iliac (23.6%) regions. A small percentage was identified in presacral (1.4%) and para-aortic regions (0.7%). Older age (P = 0.01) and an elevated body mass index (P = 0.03) were associated with decreased SLN count by preoperative single-photon emission computed tomography with computed tomography, and only age affected SLN count by gamma probe (P = 0.01). Initial surgery, large loop excision of the transformation zone, or cone biopsy of the cervix had no effect on SLN count. There was no difference observed in bilateral detection with respect to surgical approach (open: n = 48/laparoscopic: n = 84). However, older age was independently associated with a decrease in bilateral SLN detection (P = 0.003). In these patients who underwent unilateral full pelvic lymphadenectomy, all the nonsentinel nodes were negative. The majority of SLNs were located in the external iliac, obturator, and internal iliac regions. Both older age and an elevated body mass index were associated with a reduced SLN count. Unilateral detection of SLN was independently associated with older age, which may be due to sclerosis in the lymphatic vessels or reduced perfusion in the pelvis in these women. If no SLN is detected on one side, the consensus is to perform a full pelvic lymphadenectomy on that side of the pelvis.
Stanzel, Susanne; Pernthaler, Birgit; Schwarz, Thomas; Bjelic-Radisic, Vesna; Kerschbaumer, Stefan; Aigner, Reingard M
2018-06-01
of the study was to demonstrate the diagnostic and prognostic value of SPECT/CT in sentinel lymph node mapping (SLNM) in patients with invasive breast cancer. 114 patients with invasive breast cancer with clinically negative lymph nodes were included in this retrospective study as they were referred for SLNM with 99m Tc-nanocolloid. Planar image acquisition was accomplished in a one-day or two-day protocol depending on the schedule of the surgical procedure. Low dose SPECT/CT was performed after the planar images. The sentinel lymph node biopsy (SLNB) was considered false negative if a primary recurrence developed within 12 months after SLNB in the axilla from which a tumor-free SLN had been removed. Between December 2009 and December 2011, 114 patients (pts.) underwent SLNM with additional SPECT/CT. Planar imaging identified in 109 pts. 139 SLNs, which were tumor-positive in 42 nodes (n = 41 pts.). SPECT/CT identified in 81 pts. 151 additional SLNs, of which 19 were tumor-positive and led to therapy change (axillary lymph node dissection) in 11 pts. (9.6 %). Of overall 61 tumor-positive SLNs (n = 52 pts.) SPECT/CT detected all, whereas planar imaging detected only 42 of 61 ( P < 0.0001). No patient had lymph node metastasis within 12 months after SLNB in the axilla from which a tumor-free SLN had been removed resulting in a false-negative rate of 0 %. The local relapse rate was 1.8 % leading to a 4-year disease-free survival rate of 90 %. Among patients with breast cancer, the use of SPECT/CT-aided SLNM correlated due to a better anatomical localization and identification of planar not visible SLNs with a higher detection rate of SLNs. This led to therapeutic consequences and an excellent false-negative and 4-year disease-free survival rate. Schattauer GmbH.
Kohrt, Holbrook E; Olshen, Richard A; Bermas, Honnie R; Goodson, William H; Wood, Douglas J; Henry, Solomon; Rouse, Robert V; Bailey, Lisa; Philben, Vicki J; Dirbas, Frederick M; Dunn, Jocelyn J; Johnson, Denise L; Wapnir, Irene L; Carlson, Robert W; Stockdale, Frank E; Hansen, Nora M; Jeffrey, Stefanie S
2008-03-04
Current practice is to perform a completion axillary lymph node dissection (ALND) for breast cancer patients with tumor-involved sentinel lymph nodes (SLNs), although fewer than half will have non-sentinel node (NSLN) metastasis. Our goal was to develop new models to quantify the risk of NSLN metastasis in SLN-positive patients and to compare predictive capabilities to another widely used model. We constructed three models to predict NSLN status: recursive partitioning with receiver operating characteristic curves (RP-ROC), boosted Classification and Regression Trees (CART), and multivariate logistic regression (MLR) informed by CART. Data were compiled from a multicenter Northern California and Oregon database of 784 patients who prospectively underwent SLN biopsy and completion ALND. We compared the predictive abilities of our best model and the Memorial Sloan-Kettering Breast Cancer Nomogram (Nomogram) in our dataset and an independent dataset from Northwestern University. 285 patients had positive SLNs, of which 213 had known angiolymphatic invasion status and 171 had complete pathologic data including hormone receptor status. 264 (93%) patients had limited SLN disease (micrometastasis, 70%, or isolated tumor cells, 23%). 101 (35%) of all SLN-positive patients had tumor-involved NSLNs. Three variables (tumor size, angiolymphatic invasion, and SLN metastasis size) predicted risk in all our models. RP-ROC and boosted CART stratified patients into four risk levels. MLR informed by CART was most accurate. Using two composite predictors calculated from three variables, MLR informed by CART was more accurate than the Nomogram computed using eight predictors. In our dataset, area under ROC curve (AUC) was 0.83/0.85 for MLR (n = 213/n = 171) and 0.77 for Nomogram (n = 171). When applied to an independent dataset (n = 77), AUC was 0.74 for our model and 0.62 for Nomogram. The composite predictors in our model were the product of angiolymphatic invasion and size of SLN metastasis, and the product of tumor size and square of SLN metastasis size. We present a new model developed from a community-based SLN database that uses only three rather than eight variables to achieve higher accuracy than the Nomogram for predicting NSLN status in two different datasets.
Zahl Eriksson, Ane Gerda; Ducie, Jen; Ali, Narisha; McGree, Michaela E; Weaver, Amy L; Bogani, Giorgio; Cliby, William A; Dowdy, Sean C; Bakkum-Gamez, Jamie N; Abu-Rustum, Nadeem R; Mariani, Andrea; Leitao, Mario M
2016-03-01
To assess clinicopathologic outcomes between two nodal assessment approaches in patients with endometrioid endometrial carcinoma and limited myoinvasion. Patients with endometrial cancer at two institutions were reviewed. At one institution, a complete pelvic and para-aortic lymphadenectomy to the renal veins was performed in select cases deemed at risk for nodal metastasis due to grade 3 cancer and/or primary tumor diameter>2cm (LND cohort). This is a historic approach at this institution. At the other institution, a sentinel lymph node mapping algorithm was used per institutional protocol (SLN cohort). Low risk was defined as endometrioid adenocarcinoma with myometrial invasion <50%. Macrometastasis, micrometastasis, and isolated tumor cells were all considered node-positive. Of 1135 cases identified, 642 (57%) were managed with an SLN approach and 493 (43%) with an LND approach. Pelvic nodes (PLNs) were removed in 93% and 58% of patients, respectively (P<0.001); para-aortic nodes (PANs) were removed in 14.5% and 50% of patients, respectively (P<0.001). Median number of PLNs removed was 6 and 34, respectively; median number of PANs removed was 5 and 16, respectively (both P<0.001). Metastasis to PLNs was detected in 5.1% and 2.6% of patients, respectively (P=0.03), and to PANs in 0.8% and 1.0%, respectively (P=0.75). The 3-year disease-free survival rates were 94.9% (95% CI, 92.4-97.5) and 96.8% (95% CI, 95.2-98.5), respectively. Our findings support the use of either strategy for endometrial cancer staging, with no apparent detriment in adhering to the SLN algorithm. The clinical significance of disease detected on ultrastaging and the role of adjuvant therapy is yet to be determined. Copyright © 2016 Elsevier Inc. All rights reserved.
Eriksson, Ane Gerda Zahl; Ducie, Jen; Ali, Narisha; McGree, Michaela E.; Weaver, Amy L.; Bogani, Giorgio; Cliby, William A.; Dowdy, Sean C.; Bakkum-Gamez, Jamie N.; Abu-Rustum, Nadeem R.; Mariani, Andrea; Leitao, Mario M.
2016-01-01
Objectives To assess clinicopathologic outcomes between two nodal assessment approaches in patients with endometrioid endometrial carcinoma and limited myoinvasion. Methods Patients with endometrial cancer at two institutions were reviewed. At one institution, a complete pelvic and para-aortic lymphadenectomy to the renal veins was performed in select cases deemed at risk for nodal metastasis due to grade 3 cancer and/or primary tumor diameter >2 cm (LND cohort). This is a historic approach at this institution. At the other institution, a sentinel lymph node mapping algorithm was used per institutional protocol (SLN cohort). Low risk was defined as endometrioid adenocarcinoma with myometrial invasion <50%. Macrometastasis, micrometastasis, and isolated tumor cells were all considered node-positive. Results Of 1135 cases identified, 642 (57%) were managed with an SLN approach and 493 (43%) with an LND approach. Pelvic nodes (PLNs) were removed in 93% and 58% of patients, respectively (P<0.001); para-aortic nodes (PANs) were removed in 14.5% and 50% of patients, respectively (P<0.001). Median number of PLNs removed was 6 and 34, respectively; median number of PANs removed was 5 and 16, respectively (both P<0.001). Metastasis to PLNs was detected in 5.1% and 2.6% of patients, respectively (P=0.03), and to PANs in 0.8% and 1.0%, respectively (P=0.75). The 3-year disease-free survival rates were 94.9% (95%CI, 92.4–97.5) and 96.8% (95%CI, 95.2–98.5), respectively. Conclusions Our findings support the use of either strategy for endometrial cancer staging, with no apparent detriment to the SLN algorithm. The clinical significance of disease detected on ultrastaging and the role of adjuvant therapy is yet to be determined. PMID:26747778
Black sentinel lymph node and 'scary stickers'.
Yang, Arthur S; Creagh, Terrence A
2013-04-01
An unusual case is presented of a young adult patient with two black-stained, radio-nucleotide tracer-active sentinel lymph nodes biopsied following her primary cutaneous melanoma treatment. This was subsequently confirmed to be secondary to cutaneous tattoos, averting the need of an elective regional node dissection. History of tattooing and tattoo removal should therefore be obtained as a routine in all melanoma patients considered for sentinel node biopsy (SLN). SLN biopsy and any subsequent completion node dissection should be strictly staged so that proper histologic diagnosis of the sentinel node is available for correct decision making and treatment. Copyright © 2012 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
Huang, Tsai-Wei; Kuo, Ken N; Chen, Kee-Hsin; Chen, Chiehfeng; Hou, Wen-Hsuan; Lee, Wei-Hwa; Chao, Tsu-Yi; Tsai, Jo-Ting; Su, Chih-Ming; Huang, Ming-Te; Tam, Ka-Wai
2016-10-01
In 2014, the American Society of Clinical Oncology published an updated clinical practice guideline on axillary lymph node dissection (ALND) for early-stage breast cancer patients. However, these recommendations have been challenged because they were based on data from only one randomized controlled trial (RCT). We evaluated the rationale of these recommendations by systematically reviewing RCTs using the Grading of Recommendations, Assessment, Development, and Evaluations (GRADE) system. We searched articles in the PubMed, EMBASE, CINAHL, Scopus, and Cochrane databases. The primary endpoints were overall survival (OS) and disease-free survival (DFS). The secondary endpoints were recurrence rate and surgical complications of axillary dissection. The quality of evidence was assessed using the GRADE profiler. Five eligible studies were retrieved and analyzed. We divided sentinel lymph node (SLN) metastasis into two categories: SLN micrometastasis and SLN macrometastasis. In patients with 1 or 2 SLN micrometastasis, no significant difference was observed in OS, DFS, or recurrence rate between the ALND and non-ALND groups. For patients with 1 or 2 SLN marcometastasis, only one trial with a moderate risk of bias was included, and non-ALND was the preferred management overall. However, ALND might be appropriate for patients who placed a greater emphasis on longer-term survival at any cost. We recommend non-ALND management for early breast cancer patients with 1 or 2 SLN micrometastasis or macrometastasis on the basis of a systematic review of the current evidence conducted using the GRADE system. However, the optimal practice of evidence-based medicine should incorporate patient preferences, particularly when evidence is limited. Copyright © 2016 IJS Publishing Group Ltd. Published by Elsevier Ltd. All rights reserved.
Surgeon bias in sentinel lymph node dissection: Do tumor characteristics influence decision making?
Robinson, Kristin A; Pockaj, Barbara A; Wasif, Nabil; Kaufman, Katie; Gray, Richard J
2014-12-01
Determining sentinel lymph nodes (SLNs) in breast cancer staging involves subjective interpretation by the surgeon. We hypothesized patient and tumor characteristics influence number of SLNs harvested. A single-institution, prospectively collected database was queried for breast cancer patients undergoing SLN surgery (2002-2013) and mean SLN counts were compared. There were 2394 SLN biopsies. Mean number of SLNs per patient for the entire cohort was 2.6. Mean number of SLNs removed was greater for patients ≤50 years (2.9 versus 2.6; p < 0.0001). Fewer SLNs were removed with tumors ≤1 cm (2.5 versus 2.6; p = 0.002). Patients with grades 2 or 3 tumors had more SLNs removed than grade 1 (2.6 versus 2.5; p = 0.03). Receipt of neoadjuvant therapy was associated with more SLNs removed (3.0 versus 2.6; p = 0.005). Number of SLNs removed varies based on risk factors for SLN metastasis or false-negative SLN biopsy. Copyright © 2014 Elsevier Ltd. All rights reserved.
Breast cancer lymphoscintigraphy: Factors associated with sentinel lymph node non visualization.
Vaz, S C; Silva, Â; Sousa, R; Ferreira, T C; Esteves, S; Carvalho, I P; Ratão, P; Daniel, A; Salgado, L
2015-01-01
To evaluate factors associated with non identification of the sentinel lymph node (SLN) in lymphoscintigraphy of breast cancer patients and analyze the relationship with SLN metastases. A single-center, cross-sectional and retrospective study was performed. Forty patients with lymphoscintigraphy without sentinel lymph node identification (negative lymphoscintigraphy - NL) were enrolled. The control group included 184 patients with SLN identification (positive lymphoscintigraphy - PL). Evaluated factors were age, body mass index (BMI), tumor size, histology, localization, preoperative breast lesion hookwire (harpoon) marking and SLN metastases. The statistical analysis was performed with uni- and multivariate logistic regression models and matched-pairs analysis. Age (p=0.036) or having BMI (p=0.047) were the only factors significantly associated with NL. Being ≥60 years with a BMI ≥30 increased the odds of having a NL 2 and 3.8 times, respectively. Marking with hookwire seems to increase the likelihood of NL, but demonstrated statistical significance is lacking (p=0.087). The other tested variables did not affect the examination result. When controlling for age, BMI and marking with the harpoon, a significant association between lymph node metastization and NL was not found (p=0.565). The most important factors related with non identification of SLN in the patients were age, BMI and marking with hook wire. However, only the first two had statistical importance. When these variables were controlled, no association was found between NL and axillary metastases. Copyright © 2015 Elsevier España, S.L.U. and SEMNIM. All rights reserved.
Transected thin melanoma: Implications for sentinel lymph node staging.
Herbert, Garth; Karakousis, Giorgos C; Bartlett, Edmund K; Zaheer, Salman; Graham, Danielle; Czerniecki, Brian J; Fraker, Douglas L; Ariyan, Charlotte; Coit, Daniel G; Brady, Mary S
2018-03-01
Indications for sentinel lymph node (SLN) biopsy in patients with thin melanoma (≤1 mm thick) are controversial. We asked whether deep margin (DM) positivity at initial biopsy of thin melanoma is associated with SLN positivity. Cases were identified using prospectively maintained databases at two melanoma centers. Patients who had undergone SLN biopsy for melanoma ≤1 mm were included. DM status was assessed for association with SLN metastasis in univariate and multivariate analyses. 1413 cases were identified, but only 1129 with known DM status were included. 39% of patients had a positive DM on original biopsy. DM-positive and DM-negative patients did not differ significantly in primary thickness, ulceration, or mitotic activity. DM-positive and DM-negative patients had similar incidence of SLN metastasis (5.7% vs 3.5%; P = 0.07). Positive DM was not associated with SLN metastasis on univariate analysis (OR 1.69, 95% CI: 0.95-3.00, P = 0.07) or on multivariate analysis adjusted for Breslow depth, Clark level, mitotic rate, and ulceration (OR = 1.59, 95% CI: 0.89-2.85; P = 0.12). For patients with thin melanoma, a positive DM on initial biopsy is not associated with risk of SLN metastasis, so DM positivity should not be considered an indication for SLN staging in an otherwise low-risk patient. © 2017 Wiley Periodicals, Inc.
Clavier, A; Cornou, C; Capmas, P; Bats, A-S; Bensaid, C; Nos, C; Lécuru, F; Ngô, C
2016-05-01
Today, according to St-Gallen and ASCO clinical guidelines, axillary lymph node dissection (ALND) should be avoided in patients who meet the ACOSOG Z011 criteria. In French guidelines, ALND is still recommended in case of macrometastasis in sentinel lymph node (SLN) and in case of micrometastasis without systemic treatment. We performed a survey of the French practices in the management of the axilla. A questionnaire was sent to 454 breast surgeons between June 2014 and January 2015. Questionnaire included items about: indications of SLN biopsy, frequency of ALND in case of metastatic SLN and modality of radiotherapy in case of metastatic SLN without ALND. A total of 169 surgeons (37%) answer the questionnaire. Twenty-one percent of surgeons avoid ALND in case of macrometastasis. Thirty-two percent do not perform extemporaneous examination of SLN. Only 8.4% of practionners performed a SLN biopsy after neoadjuvant chemotherapy. Fourteen percent performed a SLN biopsy in case of multicentric tumors, while it is not recommended. In case of positive SLN without ALND completion, radiotherapy does not change in 34% while irradiation fields are expanded in 44%. Significant unconformities are observed towards national recommendations. The divergence between French and international guidelines leads to heterogeneous surgical practices. Copyright © 2016 Elsevier Masson SAS. All rights reserved.
Nabais, Celso; Figueiredo, Joana; Lopes, Paulina; Martins, Manuela; Araújo, António
2017-04-01
This study aimed to determine the relationship between CK19 mRNA copy number in sentinel lymph nodes (SLN) assessed by one-step nucleic acid amplification (OSNA) technique, and non-sentinel lymph nodes (NSLN) metastization in invasive breast cancer. A model using total tumor load (TTL) obtained by OSNA technique was also constructed to evaluate its predictability. We conducted an observational retrospective study including 598 patients with clinically T1-T3 and node negative invasive breast cancer. Of the 88 patients with positive SLN, 58 patients fulfill the inclusion criteria. In the analyzed group 25.86% had at least one positive NSLN in axillary lymph node dissection. Univariate analysis showed that tumor size, TTL and number of SLN macrometastases were predictive factors for NSLN metastases. In multivariate analysis just the TTL was predictive for positive NSLN (OR 2.67; 95% CI 1.06-6.70; P = 0.036). The ROC curve for the model using TTL alone was obtained and an AUC of 0.805 (95% CI 0.69-0.92) was achieved. For TTL >1.9 × 10 5 copies/μL we got 73.3% sensitivity, 74.4% specificity and 88.9% negative predictive value to predict NSLN metastases. When using OSNA technique to evaluate SLN, NSLN metastases can be predicted intraoperatively. This prediction tool could help in decision for axillary lymph node dissection. Copyright © 2016 Elsevier Ltd. All rights reserved.
Orsaria, Paolo; Caredda, Emanuele; Genova, Federica; Materazzo, Marco; Capuano, Ilaria; Vanni, Gianluca; Granai, Alessandra Vittoria; DE Majo, Adriano; Portarena, Ilaria; Sileri, Pierpaolo; Petrella, Giuseppe; Palombi, Leonardo; Buonomo, Oreste Claudio
2018-04-01
The standard-of-care in breast cancer (BC) with positive sentinel lymph node (SLN) metastasis includes complete axillary lymph node dissection (ALND); however, almost half of such cases have no further tumor burden. This study aimed to assess the clinicopathological factors that predict non-SLN metastasis to define subgroups of SLN-positive patients in whom the axilla may be staged by SLN biopsy alone, while avoiding unnecessary overtreatment. The records of 191 patients with histologically-proven primary BC who underwent a positive (SLN) biopsy between 2005 and 2017 were reviewed. Patients with at least one tumor-involved SLN who underwent completion ALND were enrolled. Demographic and clinicopathological characteristics, including age, primary tumor size and histological grade, lymphovascular invasion, ratio of positive SLNs to the harvested SLNs, SLN metastasis size, and molecular subtype classification according to immunohistochemical biomarker status [estrogen receptor (ER), progesterone receptor (PR), and human epidermal growth factor receptor 2 (HER2)], were evaluated. Data were collected retrospectively and analyzed using the Mann-Whitney and Chi-square tests (statistical significance: p<0.05). The incidence of non-SLN metastasis associated with positive SLN was 48.6% (93/191). The risk of additional nodal spread correlated with high sentinel nodal ratio >0.67 [odds ratio (OR)=2.55, p=0.032], luminal BC subtype (OR=2.67, p=0.06), HER2 overexpression (OR=0.4, p=0.016), and ER + PR - HER2 - profile (OR=2.95, p=0.027). There was a tendency (statistically insignificant; p>0.05) toward higher incidence of non SLN metastasis with increasing age and histological grade, which could be attributed to the small sample size. According to this study, sentinel nodal ratio and BC subtypes as per ER, PR, and HER2 status significantly predicted the likelihood of additional lymphatic involvement. Validation of these parameters in prospective studies is indicated, and may help individualize treatment modalities. Copyright© 2018, International Institute of Anticancer Research (Dr. George J. Delinasios), All rights reserved.
Sentinel Lymph Node Biopsy in Endometrial Cancer: a New Standard of Care?
Sullivan, Stephanie A; Rossi, Emma C
2017-09-18
Lymph node status is one of the most important factors in determining prognosis and the need for adjuvant treatment in endometrial cancer (EMCA). Unfortunately, full lymphadenectomy bears significant surgical and postoperative risks. The majority of patients with clinical stage I disease will not have metastatic disease; thus, a full lymphadenectomy only increases morbidity in this population of patients. The use of the sentinel lymph node (SLN) biopsy has emerged as an alternative to complete lymphadenectomy in EMCA. By removing the highest yield lymph nodes, the SLN biopsy has the same diagnostic ability as lymphadenectomy while minimizing morbidity. The sensitivity of sentinel lymph node identification with robotic fluorescence imaging for detecting metastatic endometrial and cervical cancer (FIRES) trial published this year is the largest prospective, multi-institution trial investigating the accuracy of the SLN biopsy for endometrial and cervical cancer. Results of this trial found an excellent sensitivity (97.2%) and false negative rate (3%) with the technique. The conclusions from the FIRES trial and those of a recent meta-analysis are that SLN biopsy has an acceptable diagnostic accuracy in detecting lymphatic metastases, and can replace lymphadenectomy for this diagnostic purpose. There remains controversy surrounding the SLN biopsy in high-risk disease and the use of adjuvant therapy in the setting of low volume disease detected with ultrastaging. Current data suggests that the technique is accurate in high-risk disease and that the increased detection of metastasis helps guide adjuvant therapy such that oncologic outcomes are likely not affected by forgoing a full lymphadenectomy. Further prospective study is needed to investigate the impact of low volume metastatic disease on oncologic outcomes and the need for adjuvant therapy in these patients.
Crott, Ralph; Lawson, Georges; Nollevaux, Marie-Cécile; Castiaux, Annick; Krug, Bruno
2016-09-01
Head and neck cancer (HNC) is predominantly a locoregional disease. Sentinel lymph node (SLN) biopsy offers a minimally invasive means of accurately staging the neck. Value in healthcare is determined by both outcomes and the costs associated with achieving them. Time-driven activity-based costing (TDABC) may offer more precise estimates of the true cost. Process maps were developed for nuclear medicine, operating room and pathology care phases. TDABC estimates the costs by combining information about the process with the unit cost of each resource used. Resource utilization is based on observation of care and staff interviews. Unit costs are calculated as a capacity cost rate, measured as a Euros/min (2014), for each resource consumed. Multiplying together the unit costs and resource quantities and summing across all resources used will produce the average cost for each phase of care. Three time equations with six different scenarios were modeled based on the type of camera, the number of SLN and the type of staining used. Total times for different SLN scenarios vary between 284 and 307 min, respectively, with a total cost between 2794 and 3541€. The unit costs vary between 788€/h for the intraoperative evaluation with a gamma-probe and 889€/h for a preoperative imaging with a SPECT/CT. The unit costs for the lymphadenectomy and the pathological examination are, respectively, 560 and 713€/h. A 10 % increase of time per individual activity generates only 1 % change in the total cost. TDABC evaluates the cost of SLN in HNC. The total costs across all phases which varied between 2761 and 3744€ per standard case.
Sentinel lymph node mapping in melanoma: the issue of false-negative findings.
Manca, Gianpiero; Rubello, Domenico; Romanini, Antonella; Boni, Giuseppe; Chiacchio, Serena; Tredici, Manuel; Mazzarri, Sara; Duce, Valerio; Colletti, Patrick M; Volterrani, Duccio; Mariani, Giuliano
2014-07-01
Management of cutaneous melanoma has changed after introduction in the clinical routine of sentinel lymph node biopsy (SLNB) for nodal staging. By defining the nodal basin status, SLNB provides a powerful prognostic information. Nevertheless, some debate still surrounds the accuracy of this procedure in terms of false-negative rate. Several large-scale studies have reported a relatively high false-negative rate (5.6%-21%), correctly defined as the proportion of false-negative results with respect to the total number of "actual" positive lymph nodes. In this review, we identified all the technical aspects that the nuclear medicine physician, the surgeon, and the pathologist should take into account to improve accuracy of the procedure and minimize the false-negative rate. In particular, SPECT/CT imaging detects more SLNs than those found by planar lymphoscintigraphy. Furthermore, the nuclear medicine community should reach a consensus on the radioactive counting rate threshold to better guide the surgeon in identifying the lymph nodes with the highest likelihood of housing metastases ("true biologic SLNs"). Analysis of the harvested SLNs by conventional techniques is also a further potential source for error. More accurate SLN analysis (eg, molecular analysis by reverse transcriptase-polymerase chain reaction) and more extensive SLN sampling identify more positive nodes, thus reducing the false-negative rate.The clinical factors identifying patients at higher-risk local recurrence after a negative SLNB include older age at diagnosis, deeper lesions, histological ulceration, and head-neck anatomic location of the primary lesion.The clinical impact of a false-negative SLNB on the prognosis of melanoma patients remains controversial, because the majority of studies have failed to demonstrate overall statistically significant disadvantage in melanoma-specific survival for false-negative SLNB patients compared with true-positive SLNB patients.When new more effective drugs will be available in the adjuvant setting for stage III melanoma patients, the implication of an accurate staging procedure for the sentinel lymph nodes will be crucial for both patients and clinicians. Standardization and accuracy of SLN identification, removal, and analysis are required.
Mücke, J; Klapdor, R; Schneider, M; Länger, F; Gratz, K F; Hillemanns, P; Hertel, H
2014-08-01
We evaluated the clinical feasibility of a new injection technique for sentinel detection in endometrial carcinoma (EC), transcervical subepithelial injection into the isthmocervical region of the myometrium. We compared detection of sentinel lymph nodes (SLN) by single photon emission computed tomography with CT (SPECT/CT) with planar lymphoscintigraphy. This is a unicentric prospective study. In all patients, transcervical injection of 10 MBq Technetium-99m-nanocolloid was performed into the isthmocervical myometrium without anaesthesia. After 40 (30-60) min, lymphoscintigraphy and SPECT/CT were performed. Patent blue was administered before surgery. The number and localisation of SLN detected in SPECT/CT and lymphoscintigraphy were recorded and compared to the SLN and non-SLN dissected intra-operatively. Between August 2008 and March 2012, 31 patients with EC were enrolled. The new transcervical injection of labelling substances led to high intra-operative (90.3%) detection rates, pelvic bilateral (57%), para-aortic (25%). SPECT/CT significantly identified more SLN than lymphoscintigraphy (mean 2.2 (1-8) to 1.3 (1-7)) in more patients (29/31 (93.5%) to 21/31 (68%), p<0.01). If SLN were identified in one hemi-pelvis, the histological evaluation of the SLN correctly predicted lymph node (LN) metastases for this basin which led to sensitivity 100%, negative predictive value (NPV) 100%, and false negative results 0%. Transcervical SLN marking in combination with SPECT/CT is easily applicable and leads to high physiologic detection rates in pelvic and para-aortic lymphatic drainage areas. Non-affected SLN truly predicted a non-affected LN basin. Combining both methods SLN dissection may be a safe and feasible staging technique for clinical routine in EC. Copyright © 2014 Elsevier Inc. All rights reserved.
Geppert, Barbara; Lönnerfors, Céline; Bollino, Michele; Arechvo, Anastasija; Persson, Jan
2017-05-01
To describe the anatomy of uterine lymphatic drainage following cervical or fundal tracer injection to enable standardization of a pelvic sentinel lymph node (SLN) concept in endometrial cancer (EC). A prospective consecutive study of women with EC was conducted. A fluorescent dye (Indocyanine green) was injected into the cervix (n=60) or the uterine fundus (n=30). A systematic trans- and retroperitoneal mapping of uterine lymphatic drainage was performed. Positions of the pelvic SLNs, defined by afferent lymph vessels, and lymph node metastases were compared. Two consistent lymphatic pathways with pelvic SLNs were identified irrespective of injection site; an upper paracervical pathway (UPP) with draining medial external and/or obturator lymph nodes and a lower paracervical pathway (LPP) with draining internal iliac and/or presacral lymph nodes. Bilateral display of at least one pelvic pathway following cervical and fundal injection occurred in 98% and 80% respectively (p=0.005). Bilateral display of both pelvic pathways occurred in 30% and 20% respectively (p=0.6) as the LPP was less often displayed. Nearly one third of the 19% node positive patients had metastases along the LPP. No false negative SLNs were identified. Based on uterine lymphatic anatomy a bilateral detection of at least one SLN in both the UPP and LPP should be aimed for. Absence of display of the LPP may warrant a full presacral lymphadenectomy. Although pelvic pathways and positions of SLNs are independent of the tracer injection site, cervical injection is preferable due to a higher technical success rate. Copyright © 2017 Elsevier Inc. All rights reserved.
Bogdanov-Berezovsky, Alexander; Pagkalos, Vasileios A.; Silberstein, Eldad; Xanthinaki, Arsinoi A.; Krieger, Yuval
2014-01-01
Background. Being predictive of the entire nodal bed, sentinel lymph node biopsy (SLNB) is invaluable in the surgical management of melanoma. Although the concept is simple, sentinel lymph node (SLN) identification and removal can be technically challenging. Methods. A total of 102 consecutive patients have undergone SLNB in the Division of Plastic and Reconstructive Surgery of Soroka University Medical Center from 2009 to 2012. Patients have undergone SLNB using a radioactive tracer and blue stain in order to identify the SLN. Although SLNB usually precedes the wide excision of melanoma, primary lesions in close proximity (<10 cm) to the lymph basin require wide excision before beginning the SLN quest. Results. All pathology reports confirmed the excision of lymph nodes. Conclusions. When treating MM in close proximity to the lymph basin, changing the sequence of the SLNB procedure seems to increase the efficacy of the method. PMID:24660067
Increased copy number of the DLX4 homeobox gene in breast axillary lymph node metastasis
Torresan, Clarissa; Oliveira, Márcia M.C.; Pereira, Silma R.F.; Ribeiro, Enilze M.S.F.; Marian, Catalin; Gusev, Yuriy; Lima, Rubens S.; Urban, Cicero A.; Berg, Patricia E.; Haddad, Bassem R.; Cavalli, Iglenir J.; Cavalli, Luciane R.
2017-01-01
DLX4 is a homeobox gene strongly implicated in breast tumor progression and invasion. Our main objective was to determine the DLX4 copy number status in sentinel lymph node (SLN) metastasis to assess its involvement in the initial stages of the axillary metastatic process. A total of 37 paired samples of SLN metastasis and primary breast tumors (PBT) were evaluated by fluorescence in situ hybridization, quantitative polymerase chain reaction and array comparative genomic hybridization assays. DLX4 increased copy number was observed in 21.6% of the PBT and 24.3% of the SLN metastasis; regression analysis demonstrated that the DLX4 alterations observed in the SLN metastasis were dependent on the ones in the PBT, indicating that they occur in the primary tumor cell populations and are maintained in the early axillary metastatic site. In addition, regression analysis demonstrated that DLX4 alterations (and other DLX and HOXB family members) occurred independently of the ones in the HER2/NEU gene, the main amplification driver on the 17q region. Additional studies evaluating DLX4 copy number in non-SLN axillary lymph nodes and/or distant breast cancer metastasis are necessary to determine if these alterations are carried on and maintained during more advanced stages of tumor progression and if could be used as a predictive marker for axillary involvement. PMID:24947980
Nakamura, Yasuhiro; Fujisawa, Yasuhiro; Nakamura, Yoshiyuki; Maruyama, Hiroshi; Furuta, Jun-ichi; Kawachi, Yasuhiro; Otsuka, Fujio
2013-06-01
The standard technique using lymphoscintigraphy, blue dye and a gamma probe has established a reliable method for sentinel node biopsy for skin cancer. However, the detection rate of cervical sentinel lymph nodes (SLN) is generally lower than that of inguinal or axillary SLN because of the complexity of lymphatic drainage in the head and neck region and the "shine-through" phenomenon. Recently, indocyanine green fluorescence imaging has been reported as a new method to detect SLN. We hypothesized that fluorescence navigation with indocyanine green in combination with the standard technique would improve the detection rate of cervical sentinel nodes. We performed cervical sentinel node biopsies using the standard technique in 20 basins of 18 patients (group A) and using fluorescence navigation in combination with the standard technique in 12 basins of 16 patients (group B). The mean number of sentinel nodes was two per basin (range, 1-4) in group A and three per basin (range, 1-5) in group B. The detection rate of sentinel nodes was 83% (29/35) in group A and 95% (36/38) in group B. The false-negative rate was 6% (1/18 patients) in group A and 0% in group B. Fluorescence navigation with indocyanine green may improve the cervical sentinel node detection rate. However, greater collection of data regarding the usefulness of cervical sentinel node biopsy using indocyanine green is necessary. © 2013 Japanese Dermatological Association.
Paulinelli, Régis Resende; Freitas-Junior, Ruffo; Rahal, Rosemar Macedo de Souza; Oliveira, Luis Fernando de Pádua; Vilela, Maria Helena Tavares; Moreira, Marise Amaral Rebouças; Alves, Katyane Larissa; Peleja, Marina Berquó; Resende, Tatiane Coelho Capel de
2017-02-01
Methylene blue is more widely available and less expensive than patent blue, with an apparently lower risk of anaphylaxis. The two dyes were compared regarding detection of the sentinel lymph node (SLN). A prospective, randomized trial involved 142 patients with invasive breast carcinoma. Sixty-nine (49.3%) assigned to patent blue (group A) and 71 (50.70%) to methylene blue (group B). Thirty-five patients (25.0%) were clinical stage III or IV; 55 (38.7%) had axillary lymph nodes affected; and 69 (49.3%) underwent neoadjuvant chemotherapy. Two patients were excluded because the dye type was not recorded. Patients and tumor characteristics were similar in both groups. SLNs were identified in 47 women (68.1%) in group A and 43 (60.6%) in group B (p=0.35). SLNs were affected in 22 cases (51.2%) in group A and 21 (48.8%) in group B (p=0.62). The SLN was the only node affected in 12 cases (54.5%) in group A and six (33.3%) in group B (p=0.18). The time and degree of difficulty involved in identifying the SLN were similar in both groups. There were no complications or allergies. Methylene blue performed as well as patent blue in identifying the SLN in breast cancer patients.
Intraoperative evaluation of sentinel lymph nodes for metastatic melanoma by imprint cytology.
Soo, Victoria; Shen, Perry; Pichardo, Rita; Azzazy, Hossam; Stewart, John H; Geisinger, Kim R; Levine, Edward A
2007-05-01
Sentinel lymph node biopsy (SLN) has revolutionized nodal staging. Accurate intraoperative evaluation of SLN permits a single procedure, with lymphadenectomy being performed during the initial operative procedure when the SLN is positive. There is a paucity of literature on intraoperative imprint cytology (IIC) evaluation of the SLN in melanoma. The purpose of this article is to present an update to our experience with IIC for SLN in melanoma. Melanoma patients had SLNs examined by IIC. SLNs were bisected, and imprints were made from each half. Imprints were stained with hematoxylin and eosin and with Diff-Quik. Paraffin-embedded sections were examined with multiple hematoxylin and eosin-stained sections from the SLNs in conjunction with immunohistochemical staining for S-100, Melan-A, and HMB-45 proteins. Metastases were identified in 40 (17%) of 229 patients. Of these, 13 patients were detected by IIC (sensitivity, 33%). The negative predictive value was 88%. No false-positive results were identified (specificity, 100%). The positive predictive value was 100%. The accuracy of IIC was 78%. The sensitivity for detecting macrometastases (>2 mm) was better than that for detecting micrometastases (< or =2 mm): 62% vs. 16% (P < .01). Patients with positive SLNs by IIC had lymphadenectomy under the same anesthetic. A total of 533 nonsentinel lymph nodes were identified in 42 patients. Only two patients (8%) had positive nonsentinel lymph nodes after a negative IIC. IIC is a viable alternative to frozen sectioning when intraoperative evaluation is desired. IIC is significantly more sensitive for macrometastases. IIC evaluation of SLNs in melanoma makes a single operative procedure possible for a significant proportion of patients with regional nodal metastases.
Sentinel lymph node biopsy in malignant melanoma of the head and neck.
Rahimi-Nedjat, Roman Kia; Al-Nawas, Bilal; Tuettenberg, Andrea; Sagheb, Keyvan; Grabbe, Stephan; Walter, Christian
2018-06-01
The aim of this retrospective study was to investigate sentinel lymph node biopsy in patients with head and neck melanoma. Patients who underwent SLNB between 2010 and 2016 were comprised. Epidemiological, radiological, and surgical data were collected and compared to histological findings. Patients who underwent primary complete lymph node dissection were excluded. 74 patients underwent SLNB during this period. The most common tumor localizations were the cheek (20.4%) and ears (20.4%). Overall, 256 sentinel lymph nodes (SLN) were detected and removed, most frequently in Robbins-levels IIA and IIB as well as in the surrounding of the parotid gland. 12.3% of the SLN showed a microscopic or macroscopic metastasis. In preoperative imaging all lymph nodes with macroscopic metastasis were described as suspect but only 4 of 11 lymph nodes with microscopic metastases were described as such. SLNB is an especially good procedure for the diagnosis of microscopically metastases as disease status is an important diagnostic and prognostic factor in early-stage melanoma patients. However, due to the complex lymphatic system in head and neck melanoma, a short follow-up interval is necessary in order to prevent delayed diagnosis of a nodal recurrence due to a false-negative SLN. Copyright © 2018 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.
Nathanson, S David; Shah, Rupen; Chitale, Dhananjay A; Mahan, Meredith
2014-01-01
Clinicians have long regarded firm enlarged axillary nodes as suspicious for metastasis, and this has been confirmed to represent increased pressure in sentinel lymph nodes (SLN) in vivo in breast cancer. We hypothesized that measuring intranodal pressure (INP) in the operating room would correlate with metastasis size and be more sensitive than clinical observation. Intranodal pressure mmHg was measured in SLNs #1 and #2 (N = 134 and 32) in 122 patients with T1/2 cN0 and 6 controls (T0) (8 bilateral). Clinical "Level of Suspicion" (LOS) was: 0 = benign; 1 = slightly suspicious; 2 = obvious metastasis. Statistical analysis was performed to compare INP, LOS, and SLN metastasis size mm. Sentinel lymph nodes met size correlated with INP (r = 0.65; p < 0.001). INP was 22.0 ± 1.3 mmHg in 35 SLNs with metastases compared with 9.3 ± 0.7 mmHg in 132 without (p < 0.001). Six groups created by combining LOS 0, 1, and 2 with INP >17 or ≤17 mmHg showed a significant (p < 0.001) correlation with SLN histology; sensitivity and specificity for LOS = 2/INP >17 mmHg = 100 % at predicting metastases; LOS = 0/INP ≤17 mmHg most often correct at predicting negative nodes (sensitivity 50 %, specificity 92.9 %, positive predictive value 55 %, negative predictive value 90.7 %). INP was better than LOS at predicting positive nodes in eight patients where INP was >17 mmHg. INP and LOS correlated significantly (p < 0.001). Clinical suspicion of metastasis correlated well with INP particularly at predicting macrometastases. INP was slightly better at predicting micrometastases. Measurement of INP may be valuable adjunct when performing SLN biopsy when further axillary surgery is contemplated.
Kim, Honsoul; Jang, Eun-Ji; Kim, Sang Kyum; Hyung, Woo Jin; Choi, Dong Kyu; Lim, Soo-Jeong; Lim, Joon Seok
2017-01-01
Purpose A sentinel lymph node (SLN) tracer can gain multi-functionality by combining it with additional components. We developed a SLN tracer consisting of iodine and docetaxel and applied it as a theragnostic nanoparticle to simultaneously perform SLN computed tomography (CT) lymphography and locoregional chemotherapy of the draining lymphatic system. Results Docetaxel could be loaded in iodine emulsions at a drug-to-surfactant weight ratio as high as that in the drug formulation Taxotere®. The particle size and drug concentration were stable during storage for up to 3 months in optimized nanoemulsions. Popliteal LN enhancement on CT was observed in all healthy rabbits (n=3) and VX2 tumor-implanted rabbits (n=6) 12 hours after injection. The rate of SLN metastasis was significantly lower in the treatment group (29.4%, 5/17) than in the non-treatment group (70.6%, 12/17) (P=0.038). Material and Methods We prepared a nanoemulsion carrying both iodine and docetaxel in a single structure by optimizing the composition of surfactants surrounding the inner iodized oil core. CT was performed 12 hours after subcutaneous injection of the emulsion in healthy rabbits (n=3) and VX2 tumor-implanted rabbits (n=6) for SLN imaging. Next, we tested the effect of treatment by histopathologically assessing the popliteal LN metastasis rate in VX2 tumor-implanted rabbits 7 days after subcutaneous injection of the emulsion (treatment group, n=17) and comparing it with that of non-treatment group rabbits (n=17). Conclusions We developed an iodine-docetaxel emulsion and demonstrated that it can be applied to simultaneously achieve CT SLN imaging and local chemotherapy against nodal metastasis. PMID:28460444
Calhoun, Benjamin C; Chambers, Karinn; Flippo-Morton, Teresa; Livasy, Chad A; Armstrong, Edward J; Symanowski, James T; Sarantou, Terry; Greene, Frederick L; White, Richard L
2014-12-01
At Carolinas Medical Center, before 2008, axillary sentinel lymph nodes (SLNs) from breast cancer patients were evaluated with a single hematoxylin and eosin-stained slide. In 2008, the protocol changed to include a limited step sectioning at 500 μm. In this study, we compared the intraoperative and permanent section pathologic findings for SLN biopsies from 2006 to 2007 to those from 2009 to 2010. We hypothesized that evaluating 2 slides would increase the detection of micrometastases and isolated tumor cells (ITCs) on permanent sections and correspondingly decrease the sensitivity of intraoperative touch preparation cytology (IOTPC). From 2006 to 2007, 140 (23.5%) of 597 of SLN permanent sections contained tumor cells: 92 macrometastases (65.7%), 36 micrometastases (25.7%), and 12 ITCs 0.2 mm or less (8.6%). The sensitivity of IOTPC for 2006 to 2007 was 51.4% for any tumor cells and 71.7% for macrometastases. From 2009 to 2010, 160 (21.9%) of 730 SLN permanent sections were positive for any tumor cells: 76 macrometastases (47.5%), 55 micrometastases (34.4%), and 29 ITCs (18.1%). The sensitivity of IOTPC for 2009 to 2010 was 39.4% for any tumor cells and 76.3% for macrometastases. With limited step sectioning, we observed an approximately 10% increase in the detection of both micrometastases and ITCs in SLN. The increased detection of ITCs on permanent sections reached statistical significance (P = .018). However, under current clinical guidelines, patients with limited SLN involvement may not be required to undergo completion axillary lymph node dissection. The ability to detect SLN tumor deposits less than 2 mm must be balanced with the clinical utility of doing so. Copyright © 2014 Elsevier Inc. All rights reserved.
Huang, Ling; Wei, Tao; Chen, Junjun; Zhou, Donghui
2017-05-16
Dual-tracer-guided sentinel lymph node (SLN) biopsy may provide a promising diagnostic tool to assess accurately the status of lymph node metastasis in the surgical operation and assure the oncologic safety of the function or stomach preserving surgery. The diagnostic performance of this technology in recent studies varied. Thus, we conducted this meta-analysis. This systematic review and meta-analysis was registered at the PROSPERO. Eligible studies were searched in the PubMed, EMBASE, Web of Knowledge, and Cochrane Library databases. A random-effect model was used to pool the data. Summary receiver operator characteristic curves, analysis for publication bias, meta-regression, and subgroup analysis were also performed. The pooled SLN identification rate and sensitivity were 0.97 and 0.89. 99m Tc-human serum albumin with indocyanine green (ICG), 99m Tc-antimony sulfur colloid with ICG, performing SLN biopsy ≥15 min after dye injection, an SLN ≥5, the basin dissection, laparoscopic surgery, in studies conducted in Japan and studies published after 2012, were associated with higher sensitivity. CT1 stage, performing SLN biopsy ≥15 min after dye injection, in studies conducted in Japan and studies published after 2012, were related with a higher identification rate. Dual tracer is promising in SLN biopsy in gastric cancer, and the clinical application of SLN biopsy should be limited to the patients of cT1N0M0 gastric cancer. The combination of 99m Tc-human serum albumin and ICG as well as the combination of 99m Tc-antimony sulfur colloid and ICG may be the optimal tracer combination. However, it seems not justified to put this technique into routine clinical application recently. Some factors that might enhance diagnostic value are identified.
Advances in radioguided surgery in oncology.
Valdés Olmos, Renato A; Vidal-Sicart, Sergi; Manca, Gianpiero; Mariani, Giuliano; León-Ramírez, Luisa F; Rubello, Domenico; Giammarile, Francesco
2017-09-01
The sentinel lymph node (SLN) biopsy is probably the most well-known radioguided technique in surgical oncology. Today SLN biopsy reduces the morbidity associated with lymphadenectomy and increases the identification rate of occult lymphatic metastases by offering the pathologist the lymph nodes with the highest probability of containing metastatic cells. These advantages may result in a change in clinical management both in melanoma and breast cancer patients. The SLN evaluation by pathology currently implies tumor burden stratification for further prognostic information. The concept of SLN biopsy includes pre-surgical lymphoscintigraphy as a "roadmap" to guide the surgeon toward the SLNs and to localize unpredictable lymphatic drainage patterns. In addition to planar images, SPECT/CT improves SLN detection, especially in sites closer to the injection site, providing anatomic landmarks which are helpful in localizing SLNs in difficult to interpret studies. The use of intraoperative imaging devices allows a better surgical approach and SLN localization. Several studies report the value of such devices for excision of additional sentinel nodes and for monitoring the whole procedure. The combination of preoperative imaging and radioguided localization constitutes the basis for a whole spectrum of basic and advanced nuclear medicine procedures, which recently have been encompassed under the term "guided intraoperative scintigraphic tumor targeting" (GOSTT). Excepting SLN biopsy, GOSTT includes procedures based on the detection of target lesions with visible uptake of tumor-seeking radiotracers on SPECT/CT or PET/CT enabling their subsequent radioguided excisional biopsy for diagnostic of therapeutic purposes. The incorporation of new PET-tracers into nuclear medicine has reinforced this field delineating new strategies for radioguided excision. In cases with insufficient lesion uptake after systemic radiotracer administration, intralesional injection of a tracer without migration may enable subsequent excision of the targeted tissue. This approach has been helpful in non-palpable breast cancer and in solitary pulmonary nodules. The introduction of allied technologies like fluorescence constitutes a recent advance aimed to refine the search for SLNs and tracer-avid lesions in the operation theatre in combination with radioguidance.
Dandekar, Monisha; Lowe, Lori; Fullen, Douglas R; Johnson, Timothy M; Sabel, Michael S; Wong, Sandra L; Patel, Rajiv M
2014-10-01
Sentinel lymph node (SLN) status currently represents the single most important prognostic factor in clinically localized melanoma and is widely used in patients with melanoma at significant risk for nodal micrometastasis. Although several studies have looked at the rates and implications of inaccuracies in the histopathologic diagnosis of melanocytic lesions, accuracy in the histologic interpretation of the SLN in melanoma has not been addressed. The goal of this study was to determine the rates of discordance in the histopathologic evaluation of the SLN and the potential clinical impact on patients referred to a comprehensive melanoma center. A prospectively collected database was queried for melanoma patients who had SLN biopsies performed at outside institutions before referral to the University of Michigan Multidisciplinary Melanoma Program between 2006 and 2009. These cases were reviewed and clinical follow-up obtained. After internal review of the SLN material, 13 (8 %) of 167 cases had major discrepancies in diagnosis that impacted patient management and prognosis. The disease of five patients was subsequently downstaged and the disease of eight patients was upstaged after internal review of the SLNs and reversal in diagnoses. There appears to be a small yet significant rate of discordance in diagnosis of the SLN for melanoma after expert histopathologic review. The implications of this discordance and revision of diagnosis is substantial. Expert histopathologic review of the SLN warrants consideration to provide the most accurate prognostic information and optimal patient care.
Mannu, G S; Navi, A; Morgan, A; Mirza, S M; Down, S K; Farooq, N; Burger, A; Hussien, M I
2012-01-01
Adjuvant post-mastectomy radiotherapy (RT), which is often unpredicted, is known to increase complications following immediate breast reconstruction (IBR). To investigate the role of sentinel lymph node biopsy (SLN) in predicting RT and improving the choice of IBR. All patients who had mastectomy and IBR between January 2004 and January 2007 were reviewed retrospectively. Axillary staging (clearance or SLN) was performed at the same time until October 2005 (Group 1), when the Unit's protocol was updated to perform SLN initially prior to mastectomy and IBR (Group 2). Patients in Group 2 with positive SLN were offered either a delayed reconstruction or a temporary subpectoral immediate tissue expander, while all options were offered if SLN was negative and in Group 1 patients. One hundred and thirty-nine patients were reviewed. 20 patients received unexpected RT in Group 1 (14 tissue expander, 4 Latissimus Dorsi flap with an implant and 2 DIEP flaps) compared to 11 patients in Group 2 who had a temporary tissue expander due to expected RT (P=0.03). Unexpected RT caused delayed complications in 14 patients (70%) compared to no delayed complications in patients who received expected RT in Group 2. SLN biopsy before IBR helps to predict RT and avoids its complications on breast reconstruction. Patients with positive SLN biopsy are best offered a temporary subpectoral tissue expander for IBR. Copyright © 2012 Surgical Associates Ltd. Published by Elsevier Ltd. All rights reserved.
Doughton, Jacki A; Hofman, Michael S; Eu, Peter; Hicks, Rodney J; Williams, Scott G
2018-05-04
Purpose: To assess feasibility, safety and utility of a novel 68 Ga-nanocolloid radio-tracer with PET-CT lymphoscintigraphy for identification of sentinel lymph nodes (SLN). Methods: Pilot study of patients from a tertiary cancer hospital who required insertion of gold fiducials for prostate cancer radiation therapy. Participation did not affect cancer management. Ultrasound-guided transperineal intra-prostatic injection of PET tracer (iron oxide nanocolloid labelled with gallium-68) after placement of fiducials. PET-CT lymphoscintigraphy imaging at approximately 45 and 100 minutes after in-jection of tracer. The study was monitored using Bayesian trial design with the as-sumption that at least one sentinel lymph node (SLN) could be identified in at least two-thirds of cases with >80% confidence. Results: SLN identification was successful in all 5 participants, allowing completion of the pilot study as per protocol. No adverse effects were observed. Unexpected po-tential pathways for transit of malignant cells as well as expected regional drainage pathways were discovered. Rapid tracer drainage to pelvic bone, perivesical, mesorec-tal, inguinal and Virchow's nodes was identified. Conclusion: SLN identification using 68 Ga-nanocolloid PET-CT can be successfully performed. Non-traditional pathways of disease spread were identified including drainage to pelvic bone as well as perivesical, mesorectal, inguinal and Virchow's nodes. Prevalence of both aberrant and non-lymphatic pathways of spread should be further investigated with this technique. Copyright © 2018 by the Society of Nuclear Medicine and Molecular Imaging, Inc.
Detection of Sentinel Lymph Nodes in Gynecologic Tumours by Planar Scintigraphy and SPECT/CT
Kraft, Otakar; Havel, Martin
2012-01-01
Objective: Assess the role of planar lymphoscintigraphy and fusion imaging of SPECT/CT in sentinel lymph node (SLN) detection in patients with gynecologic tumours. Material and Methods: Planar scintigraphy and hybrid modality SPECT/CT were performed in 64 consecutive women with gynecologic tumours (mean age 53.6 with range 30-77 years): 36 pts with cervical cancer (Group A), 21 pts with endometrial cancer (Group B), 7 pts with vulvar carcinoma (Group C). Planar and SPECT/CT images were interpreted separately by two nuclear medicine physicians. Efficacy of these two techniques to image SLN were compared. Results: Planar scintigraphy did not image SLN in 7 patients (10.9%), SPECT/CT was negative in 4 patients (6.3%). In 35 (54.7%) patients the number of SLNs captured on SPECT/CT was higher than on planar imaging. Differences in detection of SLN between planar and SPECT/CT imaging in the group of all 64 patients are statistically significant (p<0.05). Three foci of uptake (1.7% from totally visible 177 foci on planar images) in 2 patients interpreted on planar images as hot LNs were found to be false positive non-nodal sites of uptake when further assessed on SPECT/CT. SPECT/CT showed the exact anatomical location of all visualised sentinel nodes. Conclusion: In some patients with gynecologic cancers SPECT/CT improves detection of sentinel lymph nodes. It can image nodes not visible on planar scintigrams, exclude false positive uptake and exactly localise pelvic and paraaortal SLNs. It improves anatomic localization of SLNs. Conflict of interest:None declared. PMID:23486989
Morera-Sendra, Natalia; Tejera-Vaquerizo, Antonio; Traves, Víctor; Requena, Celia; Bolumar, Isidro; Pla, Angel; Vázquez, Carlos; Soriano, Virtudes; Nagore, Eduardo
2016-01-01
The role of sentinel lymph node biopsy and the benefit of immunotherapy with interferon in thick (>4 mm) melanomas remain uncertain. Our aim was to assess the value of both sentinel lymph node (SLN) biopsy and immunotherapy in the prognosis of thick melanomas. A retrospective study based on a computerized patient database in which patients have been prospectively collected since 2005 was performed. Age, sex, location, Breslow thickness, tumor ulceration, regression, Clark level, tumor infiltrating lymphocytes, tumor mitotic rate, microscopic satellite and vascular invasion were included in the analysis. Disease-free (DFS), disease-specific (DSS) and overall (OS) survivals were evaluated by the Kaplan-Meier method and Cox regression analysis. A series of 141 patients with melanomas thicker than 4 mm were included. Multivariate regression showed a worse prognosis in SLN-positive patients with respect to SLN biopsy-negative patients (DFS, hazard ratio [HR] 2, p = 0.04; DSS, HR 2.2, p = 0.002; OS, HR 2.4, p = 0.02). The observational group was shown to have a worse prognosis than the SLN-positive group but was very similar to the clinically positive group. Immunotherapy with high-dose interferon showed a protective effect (DFS, HR 0.5, p = 0.02; DSS, HR 0.3, p = 0.001; OS, HR 0.3, p = 0.001). Our data indicate that SLN biopsy and adjuvant interferon should be considered for patients with thick melanomas.
Doroud, Delaram; Zahedifard, Farnaz; Vatanara, Alireza; Taslimi, Yasaman; Vahabpour, Rouholah; Torkashvand, Fatemeh; Vaziri, Behrooz; Rouholamini Najafabadi, Abdolhossein; Rafati, Sima
2011-07-01
We have demonstrated that vaccination with pDNA encoding cysteine proteinase Type II (CPA) and Type I (CPB) with its unusual C-terminal extension (CTE) can partially protect BALB/c mice against cutaneous leishmanial infection. Unfortunately, this protection is insufficient to completely control infection without booster injection. Furthermore, in developing vaccines for leishmaniasis, it is necessary to consider a proper adjuvant and/or delivery system to promote an antigen specific immune response. Solid lipid nanoparticles have found their way in drug delivery system development against intracellular infections and cancer, but not Leishmania DNA vaccination. Therefore, undefined effect of cationic solid lipid nanoparticles (cSLN) as an adjuvant in enhancing the immune response toward leishmanial antigens led us to refocus our vaccine development projects. Three pDNAs encoding L. major cysteine proteinase type I and II (with or without CTE) were formulated by cSLN. BALB/c mice were immunized twice by 3-week interval, with cSLN-pcDNA-cpa/b, pcDNA-cpa/b, cSLN-pcDNA-cpa/b(-CTE), pcDNA-cpa/b(-CTE), cSLN, cSLN-pcDNA and PBS. Mice vaccinated with cSLN-pcDNA-cpa/b(-CTE) showed significantly higher levels of parasite inhibition related to protection with specific Th1 immune response development, compared to other groups. Parasite inhibition was determined by different techniques currently available in exploration vacciation efficacy, i.e., flowcytometry on footpad and lymph node, footpad caliper based measurements and imaging as well as lymph node microtitration assay. Among these techniques, lymph node flowcytometry was found to be the most rapid, sensitive and easily reproducible method for discrimination between the efficacy of vaccination strategies. This report demonstrates cSLN's ability to boost immune response magnitude of cpa/cpb(-CTE) cocktail vaccination against leishmaniasis so that the average parasite inhibition percent could be increased significantly. Hence, cSLNs can be considered as suitable adjuvant and/or delivery systems for designing third generation cocktail vaccines.
Implementation of molecular intra-operative assessment of sentinel lymph node in breast cancer.
Khaddage, Abir; Berremila, Sid-Ali; Forest, Fabien; Clemenson, Alix; Bouteille, Catherine; Seffert, Pierre; Peoc'h, Michel
2011-02-01
Sentinel lymph node (SLN) biopsy is used as a staging procedure in early breast cancer, however, histology based intra-operative assessment of the SLN status has a low sensitivity. The one-step nucleic acid amplification (OSNA) method was developed to detect metastases by amplification of cytokeratin (CK) 19 mRNA. Experience with OSNA during a French multi-centric prospective study, as well as intra-operative clinical routine use, is reported. For the clinical study 80 SLNs from 46 patients were assessed. During routine use, the central slice of the SLN from 197 patients was investigated by permanent histology and the remainder was assessed by OSNA. During the clinical study, OSNA detected 15/17 metastases, including all the macrometastases, reaching a 96.3% concordance rate, 88.2% sensitivity and 98.4% specificity. During routine use, both OSNA and histology detected 25 patients with metastasis. OSNA is an accurate tool for intra-operative assessment of SLN status and could reduce the need for second surgery.
Brambilla, Tatiana; Fiamengo, Barbara; Tinterri, Corrado; Testori, Alberto; Grassi, Massimo Maria; Sciarra, Amedeo; Abbate, Tommaso; Gatzemeier, Wolfgang; Roncalli, Massimo; Di Tommaso, Luca
2015-01-01
Sentinel lymph node (SLN) examination is a standard in breast cancer patients, with several methods employed along its 20 years history, the last one represented by one-step nucleic acid amplification (OSNA). The latter is a intra-operative molecular assay searching for CK19 mRNA as a surrogate of metastatic cells. Our 3 years experience with OSNA (1122 patients) showed results overlapping those recorded in the same institution with a morphological evaluation (930 patients) of SLN. In detail, the data of OSNA were almost identical to those observed with standard post-operative procedure in terms of patients with positive SLN (30%) and micrometastatic/macrometastatic involvement of SLN (respectively, 38–45 and 62–55%). By contrast, when OSNA was compared to the standard intraoperatory procedure, it was superior in terms of accuracy, prompting the use of this molecular assay as a very valid, and reproducible for intra-operative evaluation of SLN. Further possibilities prompting the use of OSNA range from adhesion to quality control programs, saving of medical time, ability to predict, during surgery, additional nodal metastasis, and molecular bio-banking. PMID:26131451
Brambilla, Tatiana; Fiamengo, Barbara; Tinterri, Corrado; Testori, Alberto; Grassi, Massimo Maria; Sciarra, Amedeo; Abbate, Tommaso; Gatzemeier, Wolfgang; Roncalli, Massimo; Di Tommaso, Luca
2015-01-01
Sentinel lymph node (SLN) examination is a standard in breast cancer patients, with several methods employed along its 20 years history, the last one represented by one-step nucleic acid amplification (OSNA). The latter is a intra-operative molecular assay searching for CK19 mRNA as a surrogate of metastatic cells. Our 3 years experience with OSNA (1122 patients) showed results overlapping those recorded in the same institution with a morphological evaluation (930 patients) of SLN. In detail, the data of OSNA were almost identical to those observed with standard post-operative procedure in terms of patients with positive SLN (30%) and micrometastatic/macrometastatic involvement of SLN (respectively, 38-45 and 62-55%). By contrast, when OSNA was compared to the standard intraoperatory procedure, it was superior in terms of accuracy, prompting the use of this molecular assay as a very valid, and reproducible for intra-operative evaluation of SLN. Further possibilities prompting the use of OSNA range from adhesion to quality control programs, saving of medical time, ability to predict, during surgery, additional nodal metastasis, and molecular bio-banking.
Whelehan, P; Vinnicombe, S J; Brown, D C; McLean, D; Evans, A
2014-08-01
To assess how accurately the sentinel lymph node (SLN) can be identified percutaneously, using gamma probe and ultrasound technology. Women with breast cancer, scheduled for wide local excision or mastectomy with SLN biopsy (SLNB), were included. Peri-areolar intradermal injection of technetium-99 nanocolloid was performed on the morning of surgery and 1-2 ml of blue dye was injected in the peri-areolar region once the patient was anaesthetized. Prior to surgery, a gamma probe was used over the skin to identify any hot spot that could represent a SLN. Ultrasound, guided by the hot spot, was then used to visualize potential SLNs and guide the insertion of a localizing wire. The accuracy in localizing the SLN by preoperative gamma-probe guided ultrasonography was assessed by comparison to SLNB. A SLN was correctly identified and marked using gamma-probe guided ultrasonography in 44 of 59 cases (75%; 95% CI: 63-86%). This study supports the case for investigating percutaneous gamma probe and ultrasound guided interventions in the axilla in women with breast cancer, as a potential alternative to surgical SLNB. Copyright © 2014 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
Schaafsma, Boudewijn E.; Mieog, J.Sven D.; Hutteman, Merlijn; van der Vorst, Joost R.; Kuppen, Peter J.K.; Löwik, Clemens W.G.M.; Frangioni, John V.; van de Velde, Cornelis J.H.; Vahrmeijer, Alexander L.
2011-01-01
Optical imaging using near-infrared (NIR) fluorescence provides new prospects for general and oncologic surgery. ICG is currently utilised in NIR fluorescence cancer-related surgery for three indications: sentinel lymph node (SLN) mapping, intraoperative identification of solid tumours, and angiography during reconstructive surgery. Therefore, understanding its advantages and limitations is of significant importance. Although non-targeted and non-conjugatable, ICG appears to be laying the foundation for more widespread use of NIR fluorescence-guided surgery. PMID:21495033
Regression and Sentinel Lymph Node Status in Melanoma Progression
Letca, Alina Florentina; Ungureanu, Loredana; Şenilă, Simona Corina; Grigore, Lavinia Elena; Pop, Ştefan; Fechete, Oana; Vesa, Ştefan Cristian
2018-01-01
Background The purpose of this study was to assess the role of regression and other clinical and histological features for the prognosis and the progression of cutaneous melanoma. Material/Methods Between 2005 and 2016, 403 patients with melanoma were treated and followed at our Department of Dermatology. Of the 403 patients, 173 patients had cutaneous melanoma and underwent sentinel lymph node (SLN) biopsy and thus were included in this study. Results Histological regression was found in 37 cases of melanoma (21.3%). It was significantly associated with marked and moderate tumor-infiltrating lymphocyte (TIL) and with negative SLN. Progression of the disease occurred in 42 patients (24.2%). On multivariate analysis, we found that a positive lymph node and a Breslow index higher than 2 mm were independent variables associated with disease free survival (DFS). These variables together with a mild TIL were significantly correlated with overall survival (OS). The presence of regression was not associated with DFS or OS. Conclusions We could not demonstrate an association between regression and the outcome of patients with cutaneous melanoma. Tumor thickness greater than 2 mm and a positive SLN were associated with recurrence. Survival was influenced by a Breslow thickness >2 mm, the presence of a mild TIL and a positive SLN status. PMID:29507279
Otsubo, Ryota; Oikawa, Masahiro; Hirakawa, Hiroshi; Shibata, Kenichiro; Abe, Kuniko; Hayashi, Tomayoshi; Kinoshita, Naoe; Shigematsu, Kazuto; Hatachi, Toshiko; Yano, Hiroshi; Matsumoto, Megumi; Takagi, Katsunori; Tsuchiya, Tomoshi; Tomoshige, Koichi; Nakashima, Masahiro; Taniguchi, Hideki; Omagari, Takeyuki; Itoyanagi, Noriaki; Nagayasu, Takeshi
2014-02-15
We developed an easy, quick and cost-effective detection method for lymph node metastasis called the semi-dry dot-blot (SDB) method, which visualizes the presence of cancer cells with washing of sectioned lymph nodes by anti-pancytokeratin antibody, modifying dot-blot technology. We evaluated the validity and efficacy of the SDB method for the diagnosis of lymph node metastasis in a clinical setting (Trial 1). To evaluate the validity of the SDB method in clinical specimens, 180 dissected lymph nodes from 29 cases, including breast, gastric and colorectal cancer, were examined. Each lymph node was sliced at the maximum diameter and the sensitivity, specificity and accuracy of the SDB method were determined and compared with the final pathology report. Metastasis was detected in 32 lymph nodes (17.8%), and the sensitivity, specificity and accuracy of the SDB method were 100, 98.0 and 98.3%, respectively (Trial 2). To evaluate the efficacy of the SDB method in sentinel lymph node (SLN) biopsy, 174 SLNs from 100 cases of clinically node-negative breast cancer were analyzed. Each SLN was longitudinally sliced at 2-mm intervals and the sensitivity, specificity, accuracy and time required for the SDB method were determined and compared with the intraoperative pathology report. Metastasis was detected in 15 SLNs (8.6%), and the sensitivity, specificity, accuracy and mean required time of the SDB method were 93.3, 96.9, 96.6 and 43.3 min, respectively. The SDB method is a novel and reliable modality for the intraoperative diagnosis of SLN metastasis. © 2013 UICC.
Current status of sentinel lymph node navigation surgery in breast and gastrointestinal tract.
Tangoku, Akira; Seike, Junichi; Nakano, Kiichiro; Nagao, Taeko; Honda, Junko; Yoshida, Takahiro; Yamai, Hiromichi; Matsuoka, Hisashi; Uyama, Kou; Goto, Masakazu; Miyoshi, Takanori; Morimoto, Tadaoki
2007-02-01
Sentinel lymph node biopsy (SLNB) has been developed as a new diagnostic and therapeutic modality in melanoma and breast cancer surgery. The purpose of the SLNB include preventing the operative morbidity and improving the pathologic stage by focusing on fewer lymph nodes using immunocytochemic and molecular technology has almost achieved in breast cancer surgery. The prognostic meaning of immunocytochemically detected micrometastases is also evaluating in the SLN and bone marrow aspirates of women with early-stage breast cancer. SLNB using available techniques have suggested that the lymphatic drainage of the gastrointestinal tract is much more complicated than other sites, skip metastasis being rather frequent because of an aberrant lymphatic drainage outside of the basin exist. At the moment, the available data does not justify reduced extent of lymphadenectomy, but provides strong evidence for an improvement in tumor staging on the basis of SLNB. Two large scale prospective multi-center trials concerning feasibility of gamma-probe and dye detection for gastric cancer are ongoing in Japan. Recent studies have shown favorable results for identification of SLN in esophageal cancer. CT lymphography with endoscopic mucosal injection of iopamidol was applicable for SLN navigation of superficial esophageal cancer. The aim of surgical treatment is complete resection of the tumor-infiltrated organ including the regional lymph nodes. Accurate detection of SLN can achieve a selection of a more sophisticated tailor made approach. The patient can make a individualized choice from a broader spectrum of therapeutic options including endoscopic, laparoscopic or laparoscopy-assisted surgery, modified radical surgery, and typical radical surgery with lymph node dissection. Ultrastaging by detecting micrometastasis at the molecular level and the choice of an adequate treatment improve the postoperative quality of life and survival. However these issues require further investigation.
Sentinel lymph node navigation surgery for early stage gastric cancer.
Mitsumori, Norio; Nimura, Hiroshi; Takahashi, Naoto; Kawamura, Masahiko; Aoki, Hiroaki; Shida, Atsuo; Omura, Nobuo; Yanaga, Katsuhiko
2014-05-21
We attempted to evaluate the history of sentinel node navigation surgery (SNNS), technical aspects, tracers, and clinical applications of SNNS using Infrared Ray Electronic Endoscopes (IREE) combined with Indocyanine Green (ICG). The sentinel lymph node (SLN) is defined as a first lymph node (LN) which receives cancer cells from a primary tumor. Reports on clinical application of SNNS for gastric cancers started to appear since early 2000s. Two prospective multicenter trials of SNNS for gastric cancer have also been accomplished in Japan. Kitagawa et al reported that the endoscopic dual (dye and radioisotope) tracer method for SN biopsy was confirmed acceptable and effective when applied to the early-stage gastric cancer (EGC). We have previously reported the usefulness of SNNS in gastrointestinal cancer using ICG as a tracer, combined with IREE (Olympus Optical, Tokyo, Japan) to detect SLN. LN metastasis rate of EGC is low. Hence, clinical application of SNNS for EGC might lead us to avoid unnecessary LN dissection, which could preserve the patient's quality of life after operation. The most ideal method of SNNS should allow secure and accurate detection of SLN, and real time observation of lymphatic flow during operation.
Sentinel lymph node navigation surgery for early stage gastric cancer
Mitsumori, Norio; Nimura, Hiroshi; Takahashi, Naoto; Kawamura, Masahiko; Aoki, Hiroaki; Shida, Atsuo; Omura, Nobuo; Yanaga, Katsuhiko
2014-01-01
We attempted to evaluate the history of sentinel node navigation surgery (SNNS), technical aspects, tracers, and clinical applications of SNNS using Infrared Ray Electronic Endoscopes (IREE) combined with Indocyanine Green (ICG). The sentinel lymph node (SLN) is defined as a first lymph node (LN) which receives cancer cells from a primary tumor. Reports on clinical application of SNNS for gastric cancers started to appear since early 2000s. Two prospective multicenter trials of SNNS for gastric cancer have also been accomplished in Japan. Kitagawa et al reported that the endoscopic dual (dye and radioisotope) tracer method for SN biopsy was confirmed acceptable and effective when applied to the early-stage gastric cancer (EGC). We have previously reported the usefulness of SNNS in gastrointestinal cancer using ICG as a tracer, combined with IREE (Olympus Optical, Tokyo, Japan) to detect SLN. LN metastasis rate of EGC is low. Hence, clinical application of SNNS for EGC might lead us to avoid unnecessary LN dissection, which could preserve the patient’s quality of life after operation. The most ideal method of SNNS should allow secure and accurate detection of SLN, and real time observation of lymphatic flow during operation. PMID:24914329
Fader, A Nickles; Edwards, R P; Cost, M; Kanbour-Shakir, A; Kelley, J L; Schwartz, B; Sukumvanich, P; Comerci, J; Sumkin, J; Elishaev, E; Rohan, L Cencia
2008-10-01
To determine the diagnostic accuracy of sentinel lymph node (SLN) detection using lymphoscintigraphy, intraoperative blue dye, and radiocolloid in patients with early-stage cervical cancer. Intra-cervical injection of technetium-99 sulfur colloid and lymphoscintigraphy were performed preoperatively. Isosulfan blue was injected intra-cervically immediately prior to surgery. SLNs were excised and examined intraoperatively (imprint cytology and frozen section) and postoperatively (H and E histology and immunohistochemistry (IHC) for cytokeratin). Thirty eight patients were evaluable. Laparoscopy and laparotomy were performed in 28.9% and 71.1%, respectively. Subjects had squamous cell carcinoma (n=26), adenocarcinoma (n=10) or adenosquamous (n=2) histologies. 55.3% had cervical tumors <2 cm. The overall SLN detection rate was 92.1%. The external iliac region just distal to the common iliac bifurcation was the most common SLN location. A mean of 2.1 SLNs were detected per patient with bilateral SLNs observed in 47.4%. On final pathology, metastatic nodal disease was identified in 15.7% of patients. Of these, 83.3% were detected in the SLNs. Sensitivity of SLN detection of metastasis was 100% for patients with cervical tumors <2 cm. However intraoperative evaluation by imprint cytology and frozen section correctly identified lymph node metastasis in only 33.3%. SLN detection is feasible and accurately reflects pelvic nodal basin status when performed in early-stage cervical cancer patients. However, while current intraoperative pathology techniques for assessing nodal metastases reliably detect metastases larger than 2 mm, they lack sufficient sensitivity to detect micrometastasis and isolated tumor cells.
Sentinel Lymph Node Biopsy Use Among Melanoma Patients 75 Years of Age and Older.
Sabel, Michael S; Kozminski, David; Griffith, Kent; Chang, Alfred E; Johnson, Timothy M; Wong, Sandra
2015-07-01
While SLN biopsy is recommended for melanoma ≥1 mm in depth, its use among the elderly population is more controversial. We reviewed our experience at the University of Michigan with melanoma patients ≥75 years of age. A total of 952 melanoma patients ≥75 years of age from 1996 to 2011 were identified from our institutional review board-approved database. In addition to clinicopathologic features and outcome data, comorbidity data were collected to calculate the Charlson comorbidity index (CCI). Univariate and multivariate Cox regression analysis was performed to characterize predictors of outcome. Kaplan-Meier analysis was used to generate survival curves. Among 553 clinically node-negative patients with melanoma ≥1 mm in Breslow thickness, 213 had wide excision alone, whereas 340 had excision and SLN biopsy, with 83 (24 %) having a positive SLN. SLN biopsy was less likely with older age (p < 0.0001) and H&N location (p = 0.007), but not CCI. SLN involvement was associated with female gender [odds ratio (OR) 2.15, p = 0.009], Breslow thickness [OR 1.23/mm increase, p = 0.004], and satellitosis (OR 4.43, p = 0.004). Distant disease-specific survival was negatively associated with male gender (OR 1.5, p = 0.007), increasing age (OR 1.05/year, p < 0.001), increasing Breslow thickness (OR 1.07/year, p = 0.013), ulceration (OR 1.51, p = 0.004), a positive SLN (OR 2.61, p < 0.001), and not having a SLN biopsy (OR 1.72, p < 0.001). CCI did not predict worse disease-free or melanoma-specific survival. WLE and SLN biopsy was not only strongly prognostic, but compared with WLE alone was associated with improved outcome, even after factoring for age and comorbidities. If otherwise healthy, SLN biopsy should be strongly considered for this population.
Stoffels, I; Dissemond, J; Körber, A; Hillen, U; Poeppel, T; Schadendorf, D; Klode, J
2011-03-01
Sentinel lymph node excision (SLNE) for the detection of regional nodal metastases and staging of malignant melanoma has resulted in some controversies in international discussions, as it is a cost-intensive surgical intervention with potentially significant morbidity. The present retrospective study seeks to clarify the effectiveness and reliability of SLNE performed under tumescent local anaesthesia (TLA) and whether SLNE performed under TLA can reduce costs and morbidity. Therefore, our study is a comparison of SLNE performed under TLA and general anaesthesia (GA). We retrospectively analysed data from 300 patients with primary malignant melanoma with a Breslow index of ≥1.0 mm. Altogether, 211 (70.3%) patients underwent SLNE under TLA and 89 (29.7%) patients underwent SLNE under GA. A total of 637 sentinel lymph nodes (SLN) were removed. In the TLA group 1.98 SLN/patient and in the GA group 2.46 SLN/patient were removed (median value). Seventy patients (23.3%) had a positive SLN. No major complications occurred. The costs for SLNE were significantly less for the SLNE in a procedures room performed under TLA (mean € 30.64) compared with SLNE in an operating room under GA (mean € 326.14, P<0.0001). In conclusion, SLNE performed under TLA is safe, reliable, and cost-efficient and could become the new gold standard in sentinel lymph node diagnostic procedures. © 2010 The Authors. Journal of the European Academy of Dermatology and Venereology © 2010 European Academy of Dermatology and Venereology.
Joyce, K M; McInerney, N M; Piggott, R P; Martin, F; Jones, D M; Hussey, A J; Kerin, M J; Kelly, J L; Regan, P J
2017-11-01
Sentinel lymph node biopsy (SLNB) is a standard method for determining the pathologic status of the regional lymph nodes. The aim of our study was to determine the incidence and clinicopathologic factors predictive of SLN positivity, and to evaluate the prognostic importance of SLNB in patients with cutaneous melanoma. We performed a retrospective analysis of a prospectively maintained database of all patients who underwent SLNB for primary melanoma at our institution from 2005 to 2012. Statistical analysis was performed using χ 2 and Fischer exact test. In total, 318 patients underwent SLNB, of which 65 were for thin melanoma (≤1 mm). There were 36 positive SLNB, 278 negative SLNB and in four cases the SLN was not located. The incidence rate for SLNB was 11.3% overall and 1.5% in thin melanomas alone. Statistical analysis identified Breslow thickness >1 mm (P = 0.006), Clark level ≥ IV (P = 0.004) and age <75 years (P = 0.035) as the strongest predictors of SLN positivity. Our overall false negativity rate was 20% (9/45) with one case of false-negative SLNB in thin melanomas. Breslow thickness of the primary tumour remains the strongest predictor of SLN positivity. Our findings point to a possible limited role for SLNB in thin melanoma due to its low positivity rate, associated false-negative rate and related morbidity.
Ribero, Simone; Osella-Abate, Simona; Pasquali, Sandro; Rossi, Carlo Riccardo; Borgognoni, Lorenzo; Piazzalunga, Dario; Solari, Nicola; Schiavon, Mauro; Brandani, Paola; Ansaloni, Luca; Ponte, Erica; Silan, Francesco; Sommariva, Antonio; Bellucci, Francesco; Macripò, Giuseppe; Quaglino, Pietro
2016-05-01
Multiple lymphatic basin drainage (MLBD) is frequently observed in patients with trunk melanoma undergoing sentinel lymph node (SLN) biopsy. Conflicting data regarding the prognostic association of MLBD in SLN-negative patients have been reported. This study aimed to investigate the prognostic role of MLBD in patients with negative SLN biopsy. Retrospective data from 656 melanoma patients who underwent a SLN biopsy (1991-2012) at six Italian centers were gathered in a multicenter database. MLBD was defined as lymphoscintigraphic and intraoperative identification of an SLN in more than one nodal basin. Clinical and pathologic variables were recorded and analyzed for their impact on survival. SLN-negative patients with MLBD were at lower risk of melanoma recurrence [hazard ratio (HR) 0.73, P = 0.05) and melanoma-related death (HR 0.68, P = 0.001) independent of common staging features. Multivariable Cox analyses of disease-free interval (DFI) and disease-specific survival (DSS) showed that MLBD maintained a favorable role and ulceration an unfavorable role. Histologic regression was independently associated only with DFI. When survival was stratified according to presence of MLBD, histologic regression and Breslow thickness <2 mm were associated with improved DFI (5-year DFI: 96.9 vs. 66,1 %, respectively; HR 0.48, P < 0.001) and DSS (5-year DSS: 96.7 vs. 71.8 %, respectively; HR 0.52, P = 0.005) compared to patients without these three favorable parameters. Patients with negative SLN biopsy results have better prognosis when two or more lymphatic basins are identified and analyzed. Further research is required to investigate the mechanisms behind this evidence.
Benke, Małgorzata; Wocial, Krzysztof; Lewandowska, Weronika; Rutkowski, Piotr Łukasz; Teterycz, Paweł; Jarek, Piotr; Dedecjus, Marek
2018-06-29
Background Localization and histopathological examination of sentinel lymph node (SLN) is a standard of melanoma treatment. The first stage of identification of the SLN is the preoperative lymphoscintigraphy. The aim of this study was to assess and compare diagnostic value of planar lymphoscintigraphy (PL) and SPECT/CT in sentinel lymph node biopsy (SLNB) procedure performed in patients with cutaneous trunk melanoma. Material and Methods Between 2015 and 2016, patients with trunk melanoma (N=255, F/M 95/160), aged from 17 to 88 after an excisional biopsy, with primary tumor ≥ pT1b (AJCC 2009, median Breslow thickness 2.0± 3.13) were included in the study. In all the patients PL was followed by SPECT/CT 1-3 h after injection of 99mTc- colloid particles, and SLNB was performed the next day. Results SPECT-CT revealed 78 (18.6%) SLN more than PL, and in 40 patients showed additional lymph drainage regions leading to surgical adjustments. In 18 patients (7.1%) SPECT-CT revealed SLN not visible in the PL (false-negative PL) and in 22 patients (8.6%), foci of uptake interpreted in PL as hot SLNs were found to be non-nodal sites of uptake when assessed on SPECT/CT (false positive PL). SPECT-CT vs. PL mismatch was observed in 31 patients (12.2%) and was the most common in patients with primary lesions located in the anterior inferior medial region (75%). Conclusions Results of the presented study indicates the high diagnostic value of SPECT-CT in assessment of SLNs and proved that SPECT-CT increases the sensitivity and accuracy of SLN identification as compared to PL even in very experienced hands.
Ryu, Jai Min; Lee, Se Kyung; Kim, Ji Young; Yu, Jonghan; Kim, Seok Won; Lee, Jeong Eon; Han, Se Hwan; Jung, Yong Sik; Nam, Seok Jin
2017-11-01
Axillary lymph node (ALN) status is an important prognostic factor for breast cancer patients. With increasing numbers of patients undergoing neoadjuvant chemotherapy (NAC), issues concerning sentinel lymph node biopsy (SLNB) after NAC have emerged. We analyzed the clinicopathologic features and developed a nomogram to predict the possibility of nonsentinel lymph node (NSLN) metastases in patients with positive SLNs after NAC. A retrospective medical record review was performed of 140 patients who had had clinically positive ALNs at presentation, had a positive SLN after NAC on subsequent SLNB, and undergone axillary lymph node dissection (ALND) from 2008 to 2014. On multivariate stepwise logistic regression analysis, pathologic T stage, lymphovascular invasion, SLN metastasis size, and number of positive SLN metastases were independent predictors for NSLN metastases (P < .05). The NAC nomogram was based on these 4 variables. A receiver operating characteristic curve was plotted, and the area under the curve (AUC) was 0.791 for the NAC nomogram. In the internal validation of performance, the AUCs for the training and test sets were 0.801 and 0.760, respectively. The nomogram was validated in an external patient cohort, with an AUC of 0.705. The Samsung Medical Center NAC nomogram was developed to predict the likelihood of additional positive NSLNs. The Samsung Medical Center NAC nomogram could provide information to surgeons regarding whether to perform additional ALND when the permanent biopsy revealed positive findings, although the intraoperative SLNB findings were negative. Copyright © 2017 Elsevier Inc. All rights reserved.
Hokimoto, Norihiro; Sugimoto, Takeki; Namikawa, Tsutomu; Funakoshi, Taku; Oki, Toyokazu; Ogawa, Maho; Fukuhara, Hideo; Inoue, Keiji; Sato, Takayuki; Hanazaki, Kazuhiro
2018-01-01
This study evaluated the clinical efficacy of a novel imaging system (HyperEye Medical System [HEMS]; Mizuho Corp., Tokyo, Japan) that uses the near-infrared (NIR) fluorescence of indocyanine green to analyze sentinel lymph node (SLN) biopsies for the staging of breast cancer. This study enrolled 91 patients with histologically confirmed breast cancer that was clinically node negative with a tumor size <3 cm. We compared SLN identification rates between HEMS and conventional methods (gamma probe scanning using a colloidal radioisotope [RI] and a blue dye method) by analyzing the relationships of lymphatic to axillary lesions and SLNs. The identification rate of SLNs was 100% using HEMS, 97.8% using the RI method, and 95.6% using the blue dye method. Two types of lymphatic pathway (LP) were detected in 39 patients (42.9%) and also clearly identified using HEMS-captured color and NIR fluorescence. The incidence of two or more SLNs was significantly higher in patients with a two-route LP to the axilla group than in those with only one route (p < 0.001; 43.6 vs. 9.6%). The HEMS NIR fluorescence color imaging method is a promising potential modality for higher-level identification of SLNs than a standard combination of the RI and blue dye methods. © 2017 S. Karger AG, Basel.
Yamamoto, Shigeru; Suga, Kazuyoshi; Maeda, Kazunari; Maeda, Noriko; Yoshimura, Kiyoshi; Oka, Masaaki
2016-05-01
To evaluate the utility of three-dimensional (3D) computed tomography (CT)-lymphography (LG) breast sentinel lymph node navigation in our institute. Between 2002 and 2013, we preoperatively identified sentinel lymph nodes (SLNs) in 576 clinically node-negative breast cancer patients with T1 and T2 breast cancer using 3D CT-LG method. SLN biopsy (SLNB) was performed in 557 of 576 patients using both the images of 3D CT-LG for guidance and the blue dye method. Using 3D CT-LG, SLNs were visualized in 569 (99%) of 576 patients. Of 569 patients, both lymphatic draining ducts and SLNs from the peritumoral and periareolar areas were visualized in 549 (96%) patients. Only SLNs without lymphatic draining ducts were visualized in 20 patients. Drainage lymphatic pathways visualized with 3D CT-LG (549 cases) were classified into four patterns: single route/single SLN (355 cases, 65%), multiple routes/single SLN (59 cases, 11%) single route/multiple SLNs (62 cases, 11%) and multiple routes/multiple SLNs (73 cases, 13%). SLNs were detected in 556 (99.8%) of 557 patients during SLNB. CT-LG is useful for preoperative visualization of SLNs and breast lymphatic draining routes. This preoperative method should contribute greatly to the easy detection of SLNs during SLNB.
Kucher, Cynthia; Zhang, Paul J; Acs, Geza; Roberts, Shelley; Xu, Xiaowei
2006-09-01
The sentinel lymph node (SLN) biopsy has become an increasingly important procedure used in the primary staging of malignant melanoma. However, micrometastases in a lymph node can be easily missed on routine H&E-stained sections. Therefore, S-100 and HMB-45 IHC stains are standardly performed on grossly negative SLNs for detection of metastatic melanoma. Each of these IHC markers, however, is not ideal. The authors investigated whether the newer IHC marker Melan-A would improve the detection of metastatic melanoma in SLN biopsies. Forty lymph nodes previously diagnosed with metastatic melanoma were retrospectively evaluated for S-100, HMB-45, and Melan-A expression. In addition, 42 SLN biopsies for metastatic melanoma detection were prospectively collected and evaluated for S-100, HMB-45, and Melan-A expression. All lymph nodes with metastatic melanoma from the retrospective study demonstrated S-100 reactivity. Five of the lymph nodes with metastatic melanoma from the retrospective study failed to express either HMB-45 or Melan-A, all of which displayed a desmoplastic morphology. One of the metastases positive for S-100 and HMB-45 failed to show reactivity with Melan-A (3%). The prospective study found 10 lymph nodes from 42 cases to be positive for metastatic melanoma, which were positive for S-100 (100%). Nine of the involved lymph nodes were positive for HMB-45(90%), and nine were positive for Melan-A (90%). Melan-A, although very specific, cannot replace the use of S-100 and HMB-45 for the detection of metastatic melanoma in SLNs. It can, however, substitute for HMB-45 with equally good results.
Marrazzo, Antonio; Boscaino, Giovanni; Marrazzo, Emilia; Taormina, Pietra; Toesca, Antonio
2015-09-01
The need for performing axillary lymph-node dissection in early breast cancer when the sentinel lymph node (SLN) is positive has been questioned in recent years. The purpose of this study was to identify a low-risk subgroup of early breast cancer patients in whom surgical axillary staging could be avoided, and to assess the probability of having a positive lymph-node (LN). We evaluated the cohort of 612 consecutive women affected by early breast cancer. We considered age, tumor size, histological grade, vascular invasion, lymphatic invasion and cancer subtype (Luminal A, Luminal B HER-2+, Luminal B HER-2-, HER-2+, and Triple Negative) as variables for univariate and multivariate analyses to assess probability of there being a positive SLN o nonsentinel lymph node (NSLN). Chi-square, Fisher's Exact test and Student's t tests were used to investigate the relationship between variables; whereas logit models were used to estimate and quantify the strength of the relationship among some covariates and SLN or the number of metastases. A significant positive effect of vascular invasion and lymphatic invasion (odds ratios are 4 and 6), and a negative effect of TN (odds ratios is 10) were noted. With respect to positive NSLN, size alone has a significant (positive) effect on tumor presence, but focusing on the number of metastases, also age has a (negative) significant effect. This work shows correlation between subtypes and the probability of having positive SLN. Patients not expressing vascular invasion, lymphatic invasion and, moreover, a triple-negative tumor subtype may be good candidates for breast conservative surgery without axillary surgical staging. Copyright © 2015 IJS Publishing Group Limited. Published by Elsevier Ltd. All rights reserved.
El Muntasar, Ahmed; Oudit, Deems
2017-01-01
Malignant melanoma (MM) on the trunk, because of its anatomical location, has multiple potential lymphatic basins to which to drain. The aim of this study is to map the location of the sentinel lymph node (SLN) on the basis of the anatomical location of the primary malignant melanoma on the trunk. Patients diagnosed with MM on the trunk who had undergone a SLN biopsy from January 2006 to March 2015 were identified in the Christie NHS Foundation Trust through a computer database search. The anterior and posterior surfaces of the trunk were divided into four sections each. A total of 212 patients were evaluated. MM was more common on the posterior trunk, accounting for 73% of cases, and 57% of melanomas were on the right side of the trunk. The axillary basins were involved in drainage in 91.5% of all truncal melanomas. Drainage was to a single lymphatic basin in 68.3% of cases. The incidence of drainage to multiple lymphatic basins was not uniform for the anterior and posterior surfaces of the trunks. One-third of MM on the posterior surface of the trunk will drain to multiple basins. Around 50% of the melanomas of the upper back drain to a contralateral basin. Independent of the location of the MM, the axillary basins were the most common location of drainage, with a total of 91% of the cohort. Therefore, the location of the SLN could be predicted, depending on the location of the MM on the trunk. Crown Copyright © 2016. Published by Elsevier Ltd. All rights reserved.
Schröder, Lars; Fricker, Roland; Stein, Roland Gregor; Rink, Thomas; Fitz, Hartmut; Blasius, Sebastian; Wöckel, Achim; Müller, Thomas
2018-06-01
Sentinel lymph node biopsy (SLNB) alone has thus become an accepted surgical approach for patients with limited axillary metastatic disease. We investigated to what extent isolated tumor cells (ITC) or micrometastasis in SLNBs is associated with proven tumor cells or metastasis in non-sentinel lymph nodes. Furthermore, we investigated the feasibility of SLNB in multifocal and multicentric tumors as both entities have been considered a contraindication for this technique. 1214 women suffering from T1 and T2 invasive breast cancer, with clinically and sonographically insuspect axillary status and undergoing primary breast cancer surgery including SLNB and axillary staging in case of SLN (sentinel lymph node) metastases, were recruited into this multicentered study. ITC and micrometastases were found in 2.01 and 21.4% of patients with SLN metastases (n = 299). Among patients with sentinel micrometastases, 4.7% showed further axillary micrometastases, while only two patients (3.1%) had two axillary macrometastases. Multifocal and multicentric tumors were diagnosed in 9.3 and 2.6% of our patients who at least had one SLN resected, respectively. Detection rates of SLNs did not differ between the cohorts suffering from unicentric and multifocal or multicentric disease. Moreover, the portion of tumor-free SLNs, the number of SLNs with metastasis as well as the mean number of resected SLNs did not differ. No patient with sentinel node micrometastases showed more than two axillary macrometastases. Multifocal and multicentric disease is no contraindication for SLNB.
Beavis, Alison; Dawson, Michael; Doble, Philip; Scolyer, Richard A.; Bourne, Roger; Li, Ling-Xi L.; Murali, Rajmohan; Stretch, Jonathan R.; Lean, Cynthia L.; Uren, Roger F.
2008-01-01
Background The sentinel lymph node (SLN) biopsy technique is a reliable means of determining the tumor-harboring status of regional lymph nodes in melanoma patients. When technetium 99 m-labeled antimony trisulfide colloid (99 mTc-Sb2S3) particles are used to perform preoperative lymphoscintigraphy for SLN identification, they are retained in the SLN but are absent or present in only tiny amounts in non-SLNs. The present study investigated the potential for a novel means of assessing the accuracy of surgical identification of SLNs. This involved the use of inductively coupled plasma–mass spectrometry (ICP-MS) to analyze antimony concentrations in fine-needle biopsy (FNB) samples from surgically procured lymph nodes. Methods A total of 47 FNB samples from surgically excised lymph nodes (32 SLNs and 15 non-SLNs) were collected. The SLNs were localized by preoperative lymphoscintigraphy that used 99 mTc-Sb2S3, blue dye, and gamma probe techniques. The concentrations of antimony were measured in the FNB samples by ICP-MS. Results The mean and median antimony concentrations (in parts per billion) were .898 and .451 in the SLNs, and .015 and .068 in the non-SLNs, the differences being highly statistically significant (P < .00005). Conclusions Our results show that ICP-MS analysis of antimony concentrations in FNB specimens from lymph nodes can accurately confirm the identity of SLNs. Used in conjunction with techniques such as proton magnetic resonance spectroscopy for the nonsurgical evaluation of SLNs, ICP-MS analysis of antimony concentrations in FNB samples could potentially serve as a minimally invasive alternative to surgery and histopathologic evaluation to objectively classify a given node as sentinel or nonsentinel and determine its tumor-harboring status. PMID:18172734
Beavis, Alison; Dawson, Michael; Doble, Philip; Scolyer, Richard A; Bourne, Roger; Li, Ling-Xi L; Murali, Rajmohan; Stretch, Jonathan R; Lean, Cynthia L; Uren, Roger F; Thompson, John F
2008-03-01
The sentinel lymph node (SLN) biopsy technique is a reliable means of determining the tumor-harboring status of regional lymph nodes in melanoma patients. When technetium 99 m-labeled antimony trisulfide colloid (99 mTc-Sb2S3) particles are used to perform preoperative lymphoscintigraphy for SLN identification, they are retained in the SLN but are absent or present in only tiny amounts in non-SLNs. The present study investigated the potential for a novel means of assessing the accuracy of surgical identification of SLNs. This involved the use of inductively coupled plasma-mass spectrometry (ICP-MS) to analyze antimony concentrations in fine-needle biopsy (FNB) samples from surgically procured lymph nodes. A total of 47 FNB samples from surgically excised lymph nodes (32 SLNs and 15 non-SLNs) were collected. The SLNs were localized by preoperative lymphoscintigraphy that used 99 mTc-Sb2S3, blue dye, and gamma probe techniques. The concentrations of antimony were measured in the FNB samples by ICP-MS. The mean and median antimony concentrations (in parts per billion) were .898 and .451 in the SLNs, and .015 and .068 in the non-SLNs, the differences being highly statistically significant (P < .00005). Our results show that ICP-MS analysis of antimony concentrations in FNB specimens from lymph nodes can accurately confirm the identity of SLNs. Used in conjunction with techniques such as proton magnetic resonance spectroscopy for the nonsurgical evaluation of SLNs, ICP-MS analysis of antimony concentrations in FNB samples could potentially serve as a minimally invasive alternative to surgery and histopathologic evaluation to objectively classify a given node as sentinel or nonsentinel and determine its tumor-harboring status.
Espinosa-Bravo, Martin; Navarro-Cecilia, Joaquin; Ramos Boyero, Manuel; Diaz-Botero, Sebastian; Dueñas Rodríguez, Basilio; Luque López, Carolina; Ramos Grande, Teresa; Ruano Perez, Ricardo; Peg, Vicente; Rubio, Isabel T
2017-02-01
Sentinel lymph node (SLN) biopsy has been shown to be both accurate and feasible for women who receive neoadjuvant chemotherapy (NAC). Intraoperative assessment of SLN by frozen sections can produce false negative results. The aim of this study was to compare two different techniques of intraoperative assessment of SLN in breast cancer patients treated with NAC: frozen section (FS) and molecular assay (OSNA). A multicenter cohort of 320 consecutive breast cancer patients treated with NAC between 2010 and 2014 was analyzed. FS was performed intraoperatively in 166 patients (H&E cohort) and OSNA in 154 patients (OSNA cohort). A mean of 2.15 SLNs by FS and 1.22 SLNs by OSNA was assessed (p = 0.03). SLN metastasis was found in 44 patients (26.5%) by FS and in 48 (31.2%) by OSNA (p = 0.4). There was no statistical significance in rates of macrometastasis (75%), micrometastasis (20.5%) or ITCs (4.5%) when assessed by FS compared to OSNA (52.3%, 36.3% and 11.4%, respectively) (p = 0.06). There were 10 patients in the H&E cohort with positive-SLN in the definitive pathology assessment with negative intraoperative FS. When OSNA and definitive pathology were compared, there were no differences in rates of macrometastasis (61.1%), micrometastasis (33.3%) nor ITCs (5.6%) (p = 0.5). Fifty-four patients in the H&E cohort and 44 in the OSNA cohort had ALND after positive-SLNs. ALND was performed in a second surgery in 10 patients (18.5%) in the H&E cohort for intraoperative FS false negative results, 90% being micrometastasis. 42 out of 44 patients (95.5%) in the OSNA cohort had an ALND in the same surgery (p = 0.03). OSNA assay detects SLNs metastases as accurately as conventional pathology in the NAC setting. Intraoperative definitive assessment of the SLN by OSNA reduces the need for a second surgery for ALND in 18.5% of breast cancer patients with a positive-SLN after NAC. Copyright © 2016 Elsevier Ltd. All rights reserved.
Selective sentinel lymph node biopsy in male breast cancer.
Martin-Marcuartu, J J; Alvarez-Perez, R M; Sousa Vaquero, J M; Jimenez-Hoyuela García, J M
To evaluate the reproducibility of the sentinel lymph node (SLN) technique in male breast cancer. We retrospectively analysed 21 male patients diagnosed with breast cancer in our hospital from 2008 to 2016 with, at least, 18 months follow-up. Fifteen patients underwent selective sentinel lymph node biopsy (SLNB) following the usual protocols with peritumoral injection of 18.5-111MBq of 99m Tc-nanocoloides and acquisition of planar images 2hours after the injection. In 2 cases it was necessary to perform a SPECT/CT to locate the SLN. Immunohistochemistry and molecular techniques (OSNA) were used for their analysis. Six patients did not undergo SLNB because they had pathological nodes or distant disease at the time of diagnosis. SLNB was performed in 15 patients. The SLN was negative in 6 patients and positive in the remaining 9. Three patients with positive SLNB did not need axillary lymphadenectomy because of the low number of copies by molecular analysis OSNA. Axillary lymphadenectomy was performed in the remaining 6 patients with the result of 4 positive axillary lymphadenectomies and 2 that did not show further extension of the disease. According to our experience, SLNB in males is a reproducible, useful, safe and reliable technique which avoids unnecessary axillary lymphadenectomy and prevents the appearance of undesirable effects. Copyright © 2017. Publicado por Elsevier España, S.L.U.
Schaafsma, Boudewijn E.; Verbeek, Floris P.R.; Rietbergen, Daphne D.D.; van der Hiel, Bernies; van der Vorst, Joost R.; Liefers, Gerrit-Jan; Frangioni, John V.; van de Velde, Cornelis J.H.; van Leeuwen, Fijs W.B.; Vahrmeijer, Alexander L.
2013-01-01
Background Combining radioactive colloids and a near-infrared (NIR) fluorophore permit preoperative planning and intraoperative localization of deeply located sentinel lymph nodes (SLNs) with direct optical guidance by a single lymphatic tracer. The aim of this clinical trial was to evaluate and optimize a hybrid NIR fluorescence and radioactive tracer for SLN detection in breast cancer patients. Method Patients with breast cancer undergoing SLN biopsy were enrolled. The day before surgery, indocyanine green (ICG)-99mTc-Nanocolloid was injected periareolarly and a lymphoscintigram was acquired. Directly before surgery, blue dye was injected. Intraoperative SLN localization was performed by a gamma probe and the Mini-FLARETM NIR fluorescence imaging system. Patients were divided into two dose groups, with one group receiving twice the particle density of ICG and nanocolloid, but the same dose of radioactive 99mTechnetium. Results Thirty-two patients were enrolled in the trial. At least one SLN was identified pre- and intraoperatively. All 48 axillary SLNs could be detected by gamma tracing and NIR fluorescence imaging, but only 42 of them stained blue. NIR fluorescence permitted detection of lymphatic vessels draining to the SLN up to 29 hours after injection. Increasing the particle density by two-fold did not yield a difference in fluorescence intensity, median 255 (range 98 – 542) vs. median 284 (90 – 921; P = 0.590), or signal- to- background ratio, median 5.4 (range 3.0 – 15.4) vs. median 4.9 (3.5 – 16.3; P = 1.000), of the SLN. Conclusion The hybrid NIR fluorescence and radioactive tracer ICG-99mTc-Nanocolloid permitted accurate pre- and intraoperative detection of the SLNs in patients with breast cancer. PMID:23696463
Minilaparoscopy vs Standard Laparoscopy for Sentinel Node Dissection: A Pilot Study.
Uccella, Stefano; Buda, Alessandro; Morosi, Chiara; Di Martino, Giampaolo; Delle Marchette, Martina; Reato, Claudio; Casarin, Jvan; Ghezzi, Fabio
To compare 3-mm minilaparoscopy and standard 5-mm laparoscopy for sentinel lymph node (SLN) detection in apparent early-stage endometrial cancer (EC). Retrospective study (Canadian Task Force classification II-2). Two academic research centers. Consecutive women with apparent early-stage EC who underwent surgical staging with SLN detection between November 2015 and April 2016. The surgical approach was a total laparoscopic extrafascial hysterectomy plus bilateral salpingo-oophorectomy and SLN detection. Systematic lymphadenectomy was performed in selected cases. In all patients, SLN detection was performed with cervical injection of indocyanine green and the use of an optical camera with a near-infrared high-intensity light source for detection of fluorescence imaging. All patients who underwent a minilaparoscopic approach (using one 5-mm scope and three 3-mm ancillary trocars) have been enrolled at the University of Insubria, whereas at the San Gerardo Hospital, standard laparoscopy was performed with one 10-mm scope and three 5-mm ancillary trocars. A total of 38 patients were enrolled, including 15 (39.5%) in the 3-mm group and 23 (60.5%) in the 5-mm group. No between-group differences were found in terms of demographic and tumor characteristics. Bilateral SLNs were detected in 73.3% of the patients in the 3-mm group and in 73.9% in the 5-mm group. Operative time, blood loss, hemoglobin drop, hospital stay, and the incidence and severity of complications were similar in the 2 groups. One patient (4.3%) in the standard 5-mm group had a positive SLN result (a micrometastasis in the left external iliac SLN). No positive SLNs were detected in the 3-mm group. Minilaparoscopic SLN biopsy appears to be a promising and feasible technique for EC staging. Further research is warranted to investigate the possible benefits of 3-mm instruments in this specific setting. Copyright © 2017 American Association of Gynecologic Laparoscopists. Published by Elsevier Inc. All rights reserved.
Fujisawa, Yasuhiro; Otsuka, Fujio
2012-10-01
The benefit of a sentinel lymph node (SLN) biopsy and adjuvant therapy for patients with thick (>4 mm) melanoma has not been well studied in the Asian population. We examined the benefit of an SLN biopsy and adjuvant therapy on prognosis in Japanese patients with thick melanoma. A review of the melanoma database collected from 26 institutions in Japan identified 291 patients with thick melanoma between 2005 and 2010. Univariate and multivariate analyses were performed to evaluate the factors predictive of the overall survival (OS) and the disease-free survival (DFS). Of the 242 patients with thick melanoma who underwent an SLN biopsy, the results for 96 (40%) were positive. On multivariate analysis, increased Breslow thickness (relative risk, 1.11; 95% confidence interval, 1.05-1.17; P=0.0002) and SLN metastasis (2.14; 1.04-4.43; P=0.040) were associated with a poor OS. Increased Breslow thickness (1.11; 1.04-1.18; P =0.0018), ulceration (3.11; 1.25-7.72; P=0.014), satellitosis (3.89; 1.62-9.31; P=0.0023), and SLN metastasis (2.24; 1.16-4.36; P=0.017) were associated with DFS. Adjuvant chemotherapy had no impact on either OS or DFS. Adjuvant use of a monthly dermal injection of interferon-β (IFN-β) was associated with a improvement in both OS (0.34; 0.17-0.67; P=0.0022) and DFS (0.42; 0.20-0.86; P=0.018). An SLN biopsy provided useful prognostic information and the adjuvant use of IFN-β improved both OS and DFS in Japanese patients with thick melanoma. These results were consistent with those of previous studies carried out on a white population. Therefore, we suggest that an SLN biopsy and adjuvant IFN should be considered for patients with thick melanoma irrespective of the Breslow thickness or ethnicity.
Meads, C; Sutton, A; Małysiak, S; Kowalska, M; Zapalska, A; Rogozinska, E; Baldwin, P; Rosenthal, A; Ganesan, R; Borowiack, E; Barton, P; Roberts, T; Sundar, S; Khan, K
2013-12-01
Vulval cancer causes 3-5% of all gynaecological malignancies and requires surgical removal and inguinofemoral lymphadenectomy (IFL). Complications affect > 50% of patients, including groin wound infection, lymphoedema and cellulitis. A sentinel lymph node (SLN) is the first groin node with the highest probability of malignancy. SLN biopsy would be useful if it could accurately identify patients in whom cancer has spread to the groin, without removing all groin nodes. SLNs can be identified by isosulfan blue dye and/or technetium-99 ((99m)Tc) radioactive tracer during lymphoscintigraphy. The blue dye/(99m)Tc procedure only detects SLN, not metastases - this requires histological examination, which can include ultrastaging and staining with conventional haematoxylin and eosin (H&E) or immunohistochemistry. To determine the test accuracy and cost-effectiveness of the SLN biopsy with (99m)Tc and/or blue dye compared with IFL or clinical follow-up for test negatives in vulval cancer, through systematic reviews and economic evaluation. Standard medical databases, including MEDLINE, EMBASE, Science Citation Index and The Cochrane Library, medical search gateways, reference lists of review articles and included studies were searched to January 2011. For accuracy and effectiveness, standard methods were used and reported according to Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. Searches were to January 2011, with no language restrictions. Meta-analyses were carried out with Meta-Disc version 1.4 (Javier Zamora, Madrid, Spain) for accuracy; none was appropriate for effectiveness. The economic evaluation from a NHS perspective used a decision-tree model in DATA TreeAge Pro Healthcare 2001 (TreeAge Software, Inc., Williamstown, MA, USA). Six options (blue dye with H&E, blue dye with ultrastaging, (99m)Tc with H&E, (99m)Tc with ultrastaging, blue dye/(99m)Tc with H&E, blue dye/(99m)Tc with ultrastaging) were compared with IFL. Deterministic and probabilistic sensitivity analyses were conducted. For accuracy, of the 26 included studies, most evaluated (99m)Tc/blue dye combined. Four studies had clinical follow-up only for test negatives and five had clinical follow-up for all and IFL for test negatives. Numbers with no SLN found were difficult to distinguish from those with negative SLN biopsies. The largest group of 11 studies using (99m)Tc/blue dye, ultrastaging and immunohistochemistry had a pooled sensitivity of 95.6% [95% confidence interval (CI) 91.5% to 98.1%] and a specificity of 100% (95% CI 99.0% to 100%). Mean SLN detection rates were 94.6% for (99m)Tc, 68.7% for blue dye and 97.7% for both. One study measured global health status quality of life (QoL) and found no difference between SLN biopsy and IFL. One patient preference evaluation showed that 66% preferred IFL rather than a 5% false-negative rate from SLN biopsy. For effectiveness, of 14,038 references, one randomised controlled trial, three case-control studies and 13 case series were found. Approximately 50% died from vulval cancer and 50% from other causes during follow-ups. Recurrences were in the ratio of approximately 4 : 2 : 1 vulval, groin and distant, with more recurrences in node-positive patients. No studies reported QoL. For cost per death averted, IFL was less costly and more effective than strategies using SLN biopsy. For morbidity-free survival and long-term morbidity-free survival, (99m)Tc with ultrastaging was most cost-effective. Strategies with blue dye only and H&E only were never cost-effective. The incremental cost-effectiveness ratio for (99m)Tc with ultrastaging compared with IFL was £4300 per case of morbidity-free survival and £7100 per long-term morbidity-free survival. The main limitations of this study include the lack of good-quality evidence on accuracy, effectiveness and QoL. A large project such as this takes time to publish, so the most recent studies are not included. A sensitive and specific combined metastatic SLN detection test and information on generic QoL in vulval cancer is urgently required. The National Institute for Health Research Health Technology Assessment programme.
Prognostic value of HPV-mRNA in sentinel lymph nodes of cervical cancer patients with pN0-status.
Dürst, Matthias; Hoyer, Heike; Altgassen, Christoph; Greinke, Christiane; Häfner, Norman; Fishta, Alba; Gajda, Mieczyslaw; Mahnert, Ute; Hillemanns, Peter; Dimpfl, Thomas; Lenhard, Miriam; Petry, K Ulrich; Runnebaum, Ingo B; Schneider, Achim
2015-09-08
Up to 15% of patients with cervical cancer and pN0-status develop recurrent-disease. This may be due to occult metastatic spread of tumor cells. We evaluated the use of human-papillomavirus-(HPV)-mRNA as a molecular marker for disseminated tumor cells to predict the risk of recurrence. For this prospective, multi-center prognostic study, 189 patients free of lymphnode metastases by conventional histopathology could be analyzed. All patients underwent complete lymphadenectomy. Of each sentinel node (SLN) a biopsy was taken for the detection of HPV-E6-E7-mRNA. Median follow-up time after surgery was 8.1 years. HPV-mRNA could be detected in SLN of 52 patients (27.5%). Recurrence was observed in 22 patients. Recurrence-free-survival was significantly longer for patients with HPV-negative SLN (log rank p = 0.002). By Cox regression analysis the hazard ratio (95%CI) for disease-recurrence was 3.8 (1.5 - 9.3, p = 0.004) for HPV-mRNA-positive compared to HPV-mRNA-negative patients. After adjustment for tumor size as the most influential covariate the HR was still 2.8 (1.1 - 7.0, p = 0.030). In patients with cervical cancer and tumor-free lymph nodes by conventional histopathology HPV-mRNA-positive SLN were of prognostic value independent of tumor size. Particularly, patients with tumors larger than 20mm diameter could possibly benefit from further risk stratification using HPV-mRNA as a molecular marker.
Intraoperative Imaging Guidance for Sentinel Node Biopsy in Melanoma Using a Mobile Gamma Camera
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dengel, Lynn T; Judy, Patricia G; Petroni, Gina R
2011-04-01
The objective is to evaluate the sensitivity and clinical utility of intraoperative mobile gamma camera (MGC) imaging in sentinel lymph node biopsy (SLNB) in melanoma. The false-negative rate for SLNB for melanoma is approximately 17%, for which failure to identify the sentinel lymph node (SLN) is a major cause. Intraoperative imaging may aid in detection of SLN near the primary site, in ambiguous locations, and after excision of each SLN. The present pilot study reports outcomes with a prototype MGC designed for rapid intraoperative image acquisition. We hypothesized that intraoperative use of the MGC would be feasible and that sensitivitymore » would be at least 90%. From April to September 2008, 20 patients underwent Tc99 sulfur colloid lymphoscintigraphy, and SLNB was performed with use of a conventional fixed gamma camera (FGC), and gamma probe followed by intraoperative MGC imaging. Sensitivity was calculated for each detection method. Intraoperative logistical challenges were scored. Cases in which MGC provided clinical benefit were recorded. Sensitivity for detecting SLN basins was 97% for the FGC and 90% for the MGC. A total of 46 SLN were identified: 32 (70%) were identified as distinct hot spots by preoperative FGC imaging, 31 (67%) by preoperative MGC imaging, and 43 (93%) by MGC imaging pre- or intraoperatively. The gamma probe identified 44 (96%) independent of MGC imaging. The MGC provided defined clinical benefit as an addition to standard practice in 5 (25%) of 20 patients. Mean score for MGC logistic feasibility was 2 on a scale of 1-9 (1 = best). Intraoperative MGC imaging provides additional information when standard techniques fail or are ambiguous. Sensitivity is 90% and can be increased. This pilot study has identified ways to improve the usefulness of an MGC for intraoperative imaging, which holds promise for reducing false negatives of SLNB for melanoma.« less
Catteau, Xavier; Simon, Philippe; Noël, Jean-Christophe
2012-04-15
15±30% of malignancies detected through screening programs are ductal carcinoma in situ (DCIS), and the majority of DCIS cases present in the form of mammographic microcalcification. This study was performed in order to determine the value of features in predicting invasive disease in patients with mammographic calcification and to help determine which patients (with, Core Needle Biopsy-diagnosed DCIS) are the most appropriate candidates for Sentinel Lymph Node (SLN) biopsy. The original aspect of this study was to select patients with mammographic microcalcification but without an associated mass. The factor that we identified to be associated with invasive disease at final surgical excision was the presence of necrosis at core histology. SLN biopsy or complete axillary lymph node dissection was performed in 22 (40%) patients of whom only one (4.5%) had a micrometastasis. Further larger studies are needed to see if it would be interesting to propose a SLN biopsy in case of necrosis on CNB-diagnosed DCIS with microcalcifications but not associated with a mass. Copyright © 2012 Elsevier GmbH. All rights reserved.
Koskas, M; Chereau, E; Ballester, M; Dubernard, G; Lécuru, F; Heitz, D; Mathevet, P; Marret, H; Querleu, D; Golfier, F; Leblanc, E; Luton, D; Rouzier, R; Daraï, E
2013-01-01
Background: We developed a nomogram based on five clinical and pathological characteristics to predict lymph-node (LN) metastasis with a high concordance probability in endometrial cancer. Sentinel LN (SLN) biopsy has been suggested as a compromise between systematic lymphadenectomy and no dissection in patients with low-risk endometrial cancer. Methods: Patients with stage I–II endometrial cancer had pelvic SLN and systematic pelvic-node dissection. All LNs were histopathologically examined, and the SLNs were examined by immunohistochemistry. We compared the accuracy of the nomogram at predicting LN detected with conventional histopathology (macrometastasis) and ultrastaging procedure using SLN (micrometastasis). Results: Thirty-eight of the 187 patients (20%) had pelvic LN metastases, 20 had macrometastases and 18 had micrometastases. For the prediction of macrometastases, the nomogram showed good discrimination, with an area under the receiver operating characteristic curve (AUC) of 0.76, and was well calibrated (average error =2.1%). For the prediction of micro- and macrometastases, the nomogram showed poorer discrimination, with an AUC of 0.67, and was less well calibrated (average error =10.9%). Conclusion: Our nomogram is accurate at predicting LN macrometastases but less accurate at predicting micrometastases. Our results suggest that micrometastases are an ‘intermediate state' between disease-free LN and macrometastasis. PMID:23481184
Unkart, Jonathan T; Hosseini, Ava; Wallace, Anne M
2017-12-01
No prior trials have compared sentinel lymph node (SLN) identification outcomes between Tc-99m tilmanocept (TcTM) and Tc-99m sulfur colloid (TcSC) in breast cancer (BC). We report on the secondary outcomes from a randomized, double-blinded, single surgeon clinical trial comparing post-injection site pain between TcTM and TcSC. Patients were randomized to receive a preoperative single, peritumoral intradermal injection of TcTM or TcSC. The number of total, "hot", and blue nodes detected and removed were compared between groups. Fifty-two (27-TcSC and 25-TcTM) patients were enrolled and underwent definitive surgical treatment. At least one "hot" SLN was detected in all patients. Three (5.8%) patients had a disease positive-SLN. The total number of SLNs removed was 61 (mean 2.26 (standard deviation (SD) 0.90)) in the TcSC group and 54 (mean 2.16 (SD 0.90)) in the TcTM group, P = 0.69. The total number of "hot" nodes in the TcSC group was 1.96 (SD 0.76) compared to 2.04 (SD 0.73) in the TcTM group, P = 0.71. The number of identified SLNs did not differ significantly between TcTM and TcSC. Given that no significant technical advantages exist between the two agents, surgeons should choose a radiopharmaceutical based on cost and side effect profile. © 2017 Wiley Periodicals, Inc.
Maza, Sofiane; Taupitz, Mathias; Taymoorian, Kasra; Winzer, Klaus Jürgen; Rückert, Jens; Paschen, Christian; Räber, Gert; Schneider, Sylke; Trefzer, Uwe; Munz, Dieter L
2007-03-01
There are situations where exact identification and localisation of sentinel lymph nodes (SLNs) are very difficult using lymphoscintigraphy, a hand-held gamma probe and vital dye, either a priori or a posteriori. We developed a new method using a simultaneous injection of two lymphotropic agents for exact topographical tomographic localisation and biopsy of draining SLNs. The purpose of this prospective pilot study was to investigate the feasibility and efficacy of this method ensemble. Fourteen patients with different tumour entities were enrolled. A mixture of (99m)Tc-nanocolloid and a dissolved superparamagnetic iron oxide was injected interstitially. Dynamic, sequential static lymphoscintigraphy and SPECT served as pathfinders. MR imaging was performed 2 h after injection. SPECT, contrast MRI and, if necessary, CT scan data sets were fused and evaluated with special regard to the topographical location of SLNs. The day after injection, nine patients underwent SLN biopsy and, in the presence of SLN metastasis, an elective lymph node dissection. Twenty-five SLNs were localised in the 14 patients examined. A 100% fusion correlation was achieved in all patients. The anatomical sites of SLNs detected during surgery showed 100% agreement with those localised on the multimodal fusion images. SLNs could be excised in 11/14 patients, six of whom had nodal metastasis. Our novel approach of multimodal fusion imaging for targeted SLN management in primary tumours with lymphatic drainage to anatomically difficult regions enables SLN biopsy even in patients with lymphatic drainage to obscure regions. Currently, we are testing its validity in larger patient groups and other tumour entities.
Photoacoustic sentinel lymph node imaging with self-assembled copper neodecanoate nanoparticles.
Pan, Dipanjan; Cai, Xin; Yalaz, Ceren; Senpan, Angana; Omanakuttan, Karthik; Wickline, Samuel A; Wang, Lihong V; Lanza, Gregory M
2012-02-28
Photoacoustic tomography (PAT) is emerging as a novel, hybrid, and non-ionizing imaging modality because of its satisfactory spatial resolution and high soft tissue contrast. PAT combines the advantages of both optical and ultrasonic imaging methods. It opens up the possibilities for noninvasive staging of breast cancer and may replace sentinel lymph node (SLN) biopsy in clinic in the near future. In this work, we demonstrate for the first time that copper can be used as a contrast metal for near-infrared detection of SLN using PAT. A unique strategy is adopted to encapsulate multiple copies of Cu as organically soluble small molecule complexes within a phospholipid-entrapped nanoparticle. The nanoparticles assumed a size of 80-90 nm, which is the optimum hydrodynamic diameter for its distribution throughout the lymphatic systems. These particles provided at least 6-fold higher signal sensitivity in comparison to blood, which is a natural absorber of light. We also demonstrated that high SLN detection sensitivity with PAT can be achieved in a rodent model. This work clearly demonstrates for the first time the potential use of copper as an optical contrast agent.
Clinical significance of sentinel lymph node detection in patients with invasive cervical cancer
NASA Astrophysics Data System (ADS)
Sinilkin, I. G.; Chernov, V. I.; Lyapunov, A. Yu.; Medvedeva, A. A.; Zelchan, R. V.; Chernyshova, A. L.; Kolomiets, L. A.; Bragina, O. D.
2017-09-01
The clinical significance of determining sentinel lymph nodes (SLN) in patients with invasive cervical cancer was studied. From 2013 to 2014, 30 cervical cancer patients (T1a1NxM0-T1b1NxM0) were treated at the Gynecological Oncology Department of the Cancer Research Institute. The day before surgery, four submucosal injections of 99mTc Al2O3 at a total dose of 80 MBq were made in each quadrant around the cervical tumor. Patients were submitted to preoperative lymphoscintigraphy and intraoperative SLN detection. The feasibility of preserving the reproductive potential in patients after radical abdominal trachelectomy was assessed. The 3-year, overall, disease-free and metastasis-free survival rates were analyzed. Thirty-four SLNs were detected by single-photon emission computed tomography (SPECT) and 42 SLNs were identified by intraoperative gamma probe. The sensitivity in detecting SLNs was 100% for intraoperative SLN identification and 80% for SPECT image. The reproductive potential was preserved in 86% of patients. The 3-year overall and metastases-free survival rates were 100%. Recurrence occurred in 8.6% of cases.
Caretta-Weyer, Holly; Sisney, Gale A; Beckman, Catherine; Burnside, Elizabeth S; Salkowsi, Lonie R; Strigel, Roberta M; Wilke, Lee G; Neuman, Heather B
2012-09-01
Our objective was to evaluate the impact of preoperative axillary ultrasound and core needle biopsy (CNB) on breast cancer treatment decision making. A secondary aim was to evaluate the impact on the utility of intraoperative sentinel lymph node (SLN) frozen section. A review of 84 patients with clinically negative axilla who underwent axillary ultrasound was performed. Sensitivity, specificity, and positive/negative predictive value for axillary ultrasound with CNB was calculated. Thirty-one (37%) had suspicious nodes. Of 27 amenable to CNB, 12 (14%) were malignant, changing treatment plans. The sensitivity of ultrasound and CNB was 54% and specificity 100%; the positive and negative predictive values were 100% and 80%, respectively. In 41 patients with normal ultrasounds who underwent SLN frozen section, 10 (24%) were positive. Preoperative axillary ultrasound impacts treatment decision making in 14%. With a sensitivity of 54%, it is a useful adjunct to, but not replacement for, SLN biopsy. Frozen section remains of utility even after a negative axillary ultrasound. Copyright © 2012 Elsevier Inc. All rights reserved.
Sentinel lymph node detection using methylene blue in patients with early stage cervical cancer.
Yuan, Song-Hua; Xiong, Ying; Wei, Mei; Yan, Xiao-Jian; Zhang, Hui-Zhong; Zeng, Yi-Xin; Liang, Li-Zhi
2007-07-01
To evaluate the feasibility of sentinel lymph node (SLN) detection in patients with cervical cancer using the low-cost methylene blue dye and to optimize the application procedure. Patients with stage Ib(1)-IIa cervical cancer and subjected to abdominal radical abdominal hysterectomy and pelvic lymphadenectomy were enrolled. Methylene blue, 2-4 ml, was injected into the cervical peritumoral area in 77 cases (4 ml patent blue in the other four cases) 10-360 min before the incision, and surgically removed lymph nodes were examined for the blue lymph nodes that were considered as SLNs. High SLN detection rate was successfully achieved when 4 ml of methylene blue was applied (93.9%, 46/49). Bilaterally SLN detection rate was significantly higher (78.1% vs. 47.1% P=0.027) in cases when the timing of application was more than 60 min before surgery than those with timing no more than 30 min. The blue color of methylene blue-stained SLNs sustained both in vivo and ex vivo, compared with the gradually faded blue color of patent blue that detected in 3 of 4 cases unilaterally. In the total of 112 dissected sides, the most common location of SLNs was the obturator basin (65.2%, 73/112), followed by external iliac area (30.4%, 34/112) and internal iliac area (26.8%, 30/112). Three patients who gave false negative results all had enlarged nodes. Methylene blue is an effective tracer to detect SLNs in patients with early stage cervical cancer. The ideal dose and timing of methylene blue application are 4 ml and 60-90 min prior surgery, respectively.
Hirano, Akira; Kamimura, Mari; Ogura, Kaoru; Kim, Naomi; Hattori, Akinori; Setoguchi, Yumika; Okubo, Fumie; Inoue, Hiroaki; Miyamoto, Reiko; Kinoshita, Jun; Fujibayashi, Mariko; Shimizu, Tadao
2012-12-01
To evaluate two methods of sentinel node navigation surgery (SNNS) using blue dye with and without indocyanine green (ICG) fluorescence imaging (FI) to determine the usefulness of combined ICG and blue dye. Between 2005 and 2010, a total of 501 patients underwent SNNS in our hospital. Detection of sentinel lymph node (SLN) was performed with sulfan blue (SB) alone until 2008 and with a combination of SB and ICG-FI since 2009. ICG 5 mg and SB 15 mg were injected in the subareolar region, and FI was obtained by a fluorescence imaging device. We attempted to identify SLNs in 393 patients by SB alone and in 108 patients by a combination of SB and FI. The mean number of SLNs detected was 1.6 (0-5) for SB alone and 2.2 (1-6) for the combination method. The SLN identification rate was 95.7 % for SB alone and 100 % for the combination method so that the combination was significantly superior to SB in terms of the identification rate (p = 0.0037). In patients who received the combination method, detection of SLN was made through only SB in 1 patient, only ICG in 8 patients, and both in 99 patients. Lymph node metastasis was found in 56 patients with SB alone and in 16 patients with the combination method. Recurrence of an axillary node was observed in 3 patients (0.8 %) with SB alone and in no patients with the combination method. ICG-FI is a useful method and is especially recommended in cases where no radiotracers are available.
Levinson, Kimberly L; Mahdi, Haider; Escobar, Pedro F
2013-01-01
The present study was performed to determine the optimal dosage of indocyanine green (ICG) to accurately differentiate the sentinel node from surrounding tissue and then to test this dosage using novel single-port robotic instrumentation. The study was performed in healthy female pigs. After induction of anesthesia, all pigs underwent exploratory laparotomy, dissection of the bladder, and colpotomy to reveal the cervical os. With use of a 21-gauge needle, 0.5 mL normal saline solution was injected at the 3- and 9-o'clock positions as control. Four concentrations of ICG were constituted for doses of 1000, 500, 250, and 175 μg per 0.5 mL. ICG was then injected at the 3- and 9-o'clock positions on the cervix. The SPY camera was used to track ICG into the sentinel nodes and to quantify the intensity of light emitted. SPY technology uses an intensity scale of 1 to 256; this scale was used to determine the difference in intensity between the sentinel node and surrounding tissues. The optimal dosage was tested using single-port robotic instrumentation with the same injection techniques. A sentinel node was identified at all doses except 175 μg, at which ICG stayed in the cervix and vasculature only. For both the 500- and 250-μg doses, the sentinel node was identified before reaching maximum intensity. At maximum intensity, the difference between the surrounding tissue and the node was 207 (251 vs 44) for the 500-μg dose and 159 (251 vs 92) for the 250-μg dose. Sentinel lymph node (SLN) biopsy was successfully performed using single-port robotic technology with both the 250- and 500-μg doses. For SLN detection, the dose of ICG is related to the ability to differentiate the sentinel node from the surrounding tissue. An ICG dose of 250 to 500 μg enables identification of a SLN with more distinction from the surrounding tissues, and this procedure is feasible using single-port robotics instrumentation. Copyright © 2013 AAGL. Published by Elsevier Inc. All rights reserved.
Huang, Yang Yang; Maurel, Amelie; Hamza, Saud; Jackson, Lee; Al-Ogaili, Zeyad
2018-06-01
To assess the impact of delayed vs immediate pre-operative lymphoscintigraphy (LSG) for sentinel lymph node biopsy in a single Australian tertiary breast cancer centre. Retrospective cohort study analysing patients with breast cancer or DCIS who underwent lumpectomy or mastectomy with pre-operative LSG and intra-operative sentinel lymph node biopsy from January 2015 to June 2016. A total of 182 LSG were performed. Group A patients had day before pre-operative LSG mapping (n = 79) and Group B had LSG mapping on the day of surgery (n = 103). The overall LSG localisation rate was 97.3% and no statistical difference was detected between the two groups. The overall sentinel lymph node biopsies (SLN) were identified in 99.6% of patients. The number of nodes excised was slightly higher in Group A (1.90 vs 1.72); however, this was not statistically significant. In addition, the number of nodes on histopathology and the incidence of second echelon nodal detection were also similar between the two groups without statistical significance. In conclusion, the 2-day LSG protocol had no impact on overall SLNB and LSG detection rates although slightly higher second tier nodes but this did not translate to any difference between the number of harvest nodes between the two groups. The 2-day LSG allows for greater flexibility in theatre planning and more efficient use of theatre time. We recommend a dose of 40 Mbq of Tc99 m pertechnetate-labelled colloid be given day prior to surgery within a 24-hour timeframe. © 2017 The Royal Australian and New Zealand College of Radiologists.
Nuclear medicine in breast cancer diagnostics: Primary tumor and lymphatic metastasis
NASA Astrophysics Data System (ADS)
Sinilkin, I.; Medvedeva, A.; Chernov, V.; Slonimskaya, E.; Zelchan, R.; Bragina, O.
2017-09-01
The purpose of the study: to assess the possibility of using nuclear medicine techniques at the stages of diagnosis and treatment of breast cancer. Materials and Methods: The study included 290 patients with breast cancer and 70 patients with benign breast tumors. The study was used as a radiopharmaceutical 99mTc-MIBI, 199Tl for imaging tumors and colloid 99mTc-Aloteh for visualization sentinel lymph nodes (SLN), colloid was injected peritumoral in four points to 80 MBq one day prior to the planned operation. Results: The sensitivity of SPECT using both 99mTc-MIBI and 199Tl for breast cancer detection was shown to be rather high, being 98.5% and 98%, respectively. It should be noted that the sensitivity of SPECT in detection of small tumors (less than 1 cm in diameter) and multicentric tumors was not high irrespective of the radioisotope used (60% and 65% with 99mTc-MIBI and 65% and 59% with 199Tl, respectively). The difference in the sensitivity was found between 99mTc-MIBI and 199T for the detection of regional lymph node metastasis (91% vs 70%). SLN were detected in 31 patients. The most commonly SLN were defined in the axillary region of 96.7%. In 22 (70.9%) patients there was no metastasis SLN. The sensitivity of the method was 91.2%, specificity of 100%. Conclusion: The specificity of SPECT with 199Tl was higher than that with 99mTc-MIBI. The data obtained show that SPECT with 199Tl can be recommended for its use as an additional breast cancer detection method in cases when other imaging techniques and histological findings are not accurate enough. The clinical study of 99mTc-Aloteh, a new radiopharmaceutical agent, has shown that the studied colloid has high uptake level in SLN and can be successfully used for visualization of SLN in patients with breast cancer.
Sentinel lymph nodes in endometrial cancer: is hysteroscopic injection valid?
Clement, D; Bats, A S; Ghazzar-Pierquet, N; Le Frere Belda, M A; Larousserie, F; Nos, C; Lecuru, F
2008-01-01
We aimed to describe hysteroscopic peritumoral tracer injection for detecting sentinel lymph nodes (SLNs) in patients with endometrial cancer and to evaluate tolerance of the procedure, detection rate and location of SLNs. Five patients with early endometrial cancer underwent hysteroscopic radiotracer injection followed by lymphoscintigraphy, then by surgery with hysteroscopic peritumoral blue dye injection, and radioactivity measurement using an endoscopic handheld gamma probe. SLNs and other nodes were sent separately to the pathology laboratory. SLNs were evaluated by hematoxylin-eosin-saffron staining and, when negative, by immunohistochemistry. Tolerance of the injection by the patients was poor (mean visual analog scale score, 8/10). SLNs were detected in only two patients (external iliac and common iliac+paraaortic, respectively). Detection rates were 1/5 by radiotracer, 1/5 by dye, and 2/5 by the combined method. One SLN was involved in a patient whose other nodes were negative. In three patients no SLNs were found by radiotracer or blue dye. Of the 83 non sentinel nodes removed from these patients, none was involved. Hysteroscopic peritumoral injection may be more difficult than cervical injection and, in our experience, carries a lower SLN detection rate.
Kwak, Yoonjin; Nam, Soo Kyung; Shin, Eun; Ahn, Sang-Hoon; Lee, Hee Eun; Park, Do Joong; Kim, Woo Ho; Kim, Hyung-Ho; Lee, Hye Seung
2016-05-01
Sentinel lymph node (SLN)-based diagnosis in gastric cancers has shown varied sensitivities and false-negative rates in several studies. Application of the reverse transcription-polymerase chain reaction (RT-PCR) in SLN diagnosis has recently been proposed. A total of 155 SLNs from 65 patients with cT1-2, N0 gastric cancer were examined. The histopathologic results were compared with results obtained by real-time RT-PCR for detecting molecular RNA (mRNA) of cytokeratin (CK)19, carcinoembryonic antigen (CEA), and CK20. The sensitivity and specificity of the multiple marker RT-PCR assay standardized against the results of the postoperative histological examination were 0.778 (95% confidence interval [CI], 0.577-0.914) and 0.781 (95% CI, 0.700-0.850), respectively. In comparison, the sensitivity and specificity of intraoperative diagnosis were 0.819 (95% CI, 0.619-0.937) and 1.000 (95% CI, 0.972-1.000), respectively. The positive predictive value of the multiple-marker RT-PCR assay was 0.355 (95% CI, 0.192-0.546) for predicting non-SLN metastasis, which was lower than that of intraoperative diagnosis (0.813, 95% CI, 0.544-0.960). The real-time RT-PCR assay could detect SLN metastasis in gastric cancer. However, the predictive value of the real-time RT-PCR assay was lower than that of precise histopathologic examination and did not outweigh that of our intraoperative SLN diagnosis. © American Society for Clinical Pathology, 2016. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Balsat, Cédric; Blacher, Silvia; Herfs, Michael; Van de Velde, Maureen; Signolle, Nicolas; Sauthier, Philippe; Pottier, Charles; Gofflot, Stéphanie; De Cuypere, Marjolein; Delvenne, Philippe; Goffin, Frédéric; Noel, Agnès; Kridelka, Frédéric
2017-01-01
ABSTRACT The lymph node (LN) pre-metastatic niche is faintly characterized in lymphophilic human neoplasia, although LN metastasis is considered as the strongest prognostic marker of patient survival. Due to its specific dissemination through a complex bilateral pelvic lymphatic system, early cervical cancer is a relevant candidate for investigating the early nodal metastatic process. In the present study, we analyzed in-depth both the lymphatic vasculature and the immune climate of pre-metastatic sentinel LN (SLN), in 48 cases of FIGO stage IB1 cervical neoplasms. An original digital image analysis methodology was used to objectively determine whole slide densities and spatial distributions of immunostained structures. We observed a marked increase in lymphatic vessel density (LVD) and a specific capsular and subcapsular distribution in pre-metastatic SLN when compared with non-sentinel counterparts. Such features persisted in the presence of nodal metastatic colonization. The inflammatory profile attested by CD8+, Foxp3, CD20 and PD-1expression was also significantly increased in pre-metastatic SLN. Remarkably, the densities of CD20+ B cells and PD-1 expressing germinal centers were positively correlated with LVD. All together, these data strongly support the existence of a pre-metastatic dialog between the primary tumor and the first nodal relay. Both lymphatic and immune responses contribute to the elaboration of a specific pre-metastatic microenvironment in human SLN. Moreover, this work provides evidence that, in the context of early cervical cancer, a pre-metastatic lymphangiogenesis occurs within the SLN (pre-metastatic niche) and is associated with a specific humoral immune response. PMID:28344873
NASA Astrophysics Data System (ADS)
Chi, Chongwei; Kou, Deqiang; Ye, Jinzuo; Mao, Yamin; Qiu, Jingdan; Wang, Jiandong; Yang, Xin; Tian, Jie
2015-03-01
Introduction: Precision and personalization treatments are expected to be effective methods for early stage cancer studies. Breast cancer is a major threat to women's health and sentinel lymph node biopsy (SLNB) is an effective method to realize precision and personalized treatment for axillary lymph node (ALN) negative patients. In this study, we developed a surgical navigation system (SNS) based on optical molecular imaging technology for the precise detection of the sentinel lymph node (SLN) in breast cancer patients. This approach helps surgeons in precise positioning during surgery. Methods: The SNS was mainly based on the technology of optical molecular imaging. A novel optical path has been designed in our hardware system and a feature-matching algorithm has been devised to achieve rapid fluorescence and color image registration fusion. Ten in vivo studies of SLN detection in rabbits using indocyanine green (ICG) and blue dye were executed for system evaluation and 8 breast cancer patients accepted the combination method for therapy. Results: The detection rate of the combination method was 100% and an average of 2.6 SLNs was found in all patients. Our results showed that the method of using SNS to detect SLN has the potential to promote its application. Conclusion: The advantage of this system is the real-time tracing of lymph flow in a one-step procedure. The results demonstrated the feasibility of the system for providing accurate location and reliable treatment for surgeons. Our approach delivers valuable information and facilitates more detailed exploration for image-guided surgery research.
Frozen section analysis and sentinel lymph node biopsy in well differentiated thyroid cancer
2013-01-01
Background The aim of this study is to prospectively review the role of sentinel lymph node (SLN) biopsy in the management of well differentiated thyroid carcinoma (WDTC), and to determine the efficacy of intraoperative frozen section analysis at detecting SLN metastasis and central compartment involvement. Methods The SLN biopsy protocol using 1% methylene blue was performed in 300 patients undergoing thyroidectomy for WDTC. A limited pretracheal central compartment neck dissection (CCND) was performed on all patients. Lymph nodes staining blue were considered as SLN’s. Both frozen and permanent section analyses were performed. Results SLN’s with metastasis were found in 14.3% (43/300) of cases. Of this, 11% (33/300) were positive on intraoperative frozen section analysis. Frozen section results failed in predicting central compartment involvement in 15 cases (5%) whereas central neck compartment involvement was missed in 5 cases (1.7%) when based on permanent section results. On frozen section analysis, the sensitivity, specificity, positive predictive value and negative predictive value (95% CI) of our SLN biopsy technique aiming to remove all disease from the central compartment was 68.8% (53.6-80.9), 100% (98.1-100), 100% (87.0-100) and 94.4% (90.7-96.7) respectively with P < 0.0001. On permanent section analysis, the values were 89.6% (76.6-96.1), 100% (98.1-100), 100% (89.8-100), and 98.1% (95.3-99.3) with P < 0.0001. Conclusion This data series demonstrates that patients with WDTC have positive SLN’s in 14.3% of cases. Moreover, when the SLN’s are negative for metastasis on frozen section, the central compartment was disease-free in 94.4% of cases. Finally, this study shows that 23.3% of positive SLN’s were false negatives on intraoperative frozen section. According to this data, SLN involvement is an accurate predictor of central compartment metastasis, however surgeons should use caution when relying on intraoperative frozen section to determine whether to perform a CCND. PMID:24025621
Dordea, Matei; Colvin, Hugh; Cox, Phil; Pujol Nicolas, Andrea; Kanakala, Venkat; Iwuchukwu, Obi
2013-04-01
Sentinel lymph node biopsy (SLNB) has become the standard of care in axillary staging of clinically node-negative breast cancer patients. To analyze reasons for failure of SLN localization by means of a multivariate analysis of clinical and histopathological factors. We performed a review of 164 consecutive breast cancer patients who underwent SLNB. A superficial injection technique was used. 9/164 patients failed to show nodes. In 7/9 patients no evidence of radioactivity or blue dye was observed. Age and nodal status were the only statistically significant factors (p < 0.05). For every unit increase in age there was a 9% reduced chance of failed SLN localization. Patients with negative nodal status have 90% reduced risk of failed sentinel node localization than patients with macro or extra capsular nodal invasion. The results suggest that altered lymphatic dynamics secondary to tumour burden may play a role in failed sentinel node localization. We showed that in all failed localizations the radiocolloid persisted around the injection site, showing limited local diffusion only. While clinical and histopathological data may provide some clues as to why sentinel node localization fails, we further hypothesize that integrity of peri-areolar lymphatics is important for successful localization. Copyright © 2012 Royal College of Surgeons of Edinburgh (Scottish charity number SC005317) and Royal College of Surgeons in Ireland. Published by Elsevier Ltd. All rights reserved.
Sentinel node detection in cervical cancer with (99m)Tc-phytate.
Silva, Lucas B; Silva-Filho, Agnaldo L; Traiman, Paulo; Triginelli, Sérgio A; de Lima, Carla Flávia; Siqueira, Cristiano Ferrari; Barroso, Adelanir; Rossi, Telma Maria F F; Pedrosa, Moises Salgado; Miranda, Dairton; Melo, José Renan Cunha
2005-05-01
The aim of this study was to investigate the feasibility of sentinel lymph node (SLN) identification using radioisotopic lymphatic mapping with technetium-99 m-labeled phytate in patients undergoing radical hysterectomy with pelvic lymphadenectomy for treatment of early cervical cancer. Between July 2001 and February 2003, 56 patients with cervical cancer FIGO stage I (n = 53) or stage II (n = 3) underwent sentinel lymph node detection with preoperative lymphoscintigraphy ((99m)Tc-labeled phytate injected into the uterine cervix, at 3, 6, 9, and 12 o'clock, at a dose of 55-74 MBq in a volume of 0.8 ml) and intraoperative lymphatic mapping with a handheld gamma probe. Radical hysterectomy was aborted in three cases because parametrial invasion was found intraoperatively and we performed only sentinel node resection. The remaining 53 patients underwent radical hysterectomy with complete pelvic lymphadenectomy. Sentinel nodes were detected using a handheld gamma-probe and removed for pathological assessment during the abdominal radical hysterectomy and pelvic lymphadenectomy. One or more sentinel nodes were detected in 52 out of 56 eligible patients (92.8%). A total of 120 SLNs were detected by lymphoscintigraphy (mean 2.27 nodes per patient) and intraoperatively by gamma probe. Forty-four percent of SLNs were found in the external iliac area, 39% in the obturator region, 8.3% in interiliac region, and 6.7% in the common iliac area. Unilateral sentinel nodes were found in thirty-one patients (59%). The remaining 21 patients (41%) had bilateral sentinel nodes. Microscopic nodal metastases were confirmed in 17 (32%) cases. In 10 of these patients, only SLNs had metastases. The 98 sentinel nodes that were negative on hematoxylin and eosin were submitted to cytokeratin immunohistochemical analysis. Five (5.1%) micrometastases were identified with this technique. The sensitivity of the sentinel node was 82.3% (CI 95% = 56.6-96.2) and the negative predictive value was 92.1% (CI 95% = 78.6-98.3). The accuracy of sentinel node in predicting the lymph node status was 94.2%. Preoperative lymphoscintigraphy and intraoperative lymphatic mapping with (99m)Tc-labeled phytate are effective in identifying sentinel nodes in patients undergoing radical hysterectomy and to select women in whom lymph node dissection can be avoided.
Lu, Yan; Wei, Jin-Ying; Yao, De-Sheng; Pan, Zhong-Mian; Yao, Yao
2017-01-01
To investigate the value of carbon nanoparticles in identifying sentinel lymph nodes in early-stage cervical cancer. From January 2014 to January 2016, 40 patients with cervical cancer stage IA2-IIA, based on the International Federation of Gynecology and Obstetrics (FIGO) 2009 criteria, were included in this study. The normal cervix around the tumor was injected with a total of 1 mL of carbon nanoparticles (CNP)at 3 and 9 o'clock. All patients then underwent laparoscopic pelvic lymph node dissection and radical hysterectomy. The black-dyed sentinel lymph nodes were removed for routine pathological examination and immunohistochemical staining. Among the 40 patients, 38 patients had at least one sentinel lymph node (SLN). The detection rate was 95% (38/40). One hundred seventy-three SLNs were detected with an average of 3.9 SLNs per side. 25 positive lymph nodes, which included 21 positive SLNs, were detected in 8 (20%) patients. Sentinel lymph nodes were localized in the obturator (47.97%), internal lilac (13.87%), external lilac (26.59%), parametrial (1.16%), and common iliac (8.67%) regions. The sensitivity of the SLN detection was 100% (5/5), the accuracy was 97.37% (37/38), and the negative predictive value was 100. 0% and the false negative rate was 0%. Sentinel lymph nodes can be used to accurately predict the pathological state of pelvic lymph nodes in early cervical cancer. The detection rates and accuracy of sentinel lymph node were high. Carbon nanoparticles can be used to trace the sentinel lymph node in early cervical cancer.
The use of 99mTc-Al2O3 for detection of sentinel lymph nodes in cervical cancer patients
NASA Astrophysics Data System (ADS)
Sinilkin, I. G.; Chernov, V. I.; Lyapunov, A. Yu; Medvedeva, A. A.; Zelchan, R. V.; Chernyshova, A. L.; Kolomiets, L. A.
2016-06-01
The purpose of the study was to evaluate the feasibility of using 99mTc-Al2O3- based radiopharmaceutical, a novel molecular imaging agent for sentinel lymph node detection in patients with invasive cervical cancer. The study included 23 cervical cancer patients (TlaNxMx- T2bNxMx) treated at the Tomsk Cancer Research Institute. At 18 hours before surgery, 80 MBq of the 99mTc-Al2O3 were injected peritumorally, followed by single-photon emission computed tomography (SPECT) of the pelvis and intraoperative SLN identification. Twenty-seven SLNs were detected by SPECT, and 34 SLNs were identified by intraoperative gamma probe. The total number of identified SLNs per patient ranged from 1 to 3(the mean number of SLNs was 1.4 per patient). The most common site for SLN detection was the external iliac region (57.2%), followed by the internal iliac, obturator, presacral and retrosacral regions (they amounted to 14%, respectively),and the parametrial region (1%). Sensitivity in detecting SLNs was 100% for intraoperative SLN identification and 79% for SPECT image.
NASA Astrophysics Data System (ADS)
Sinilkin, I. G.; Chernov, V. I.; Lyapunov, A. Yu.; Medvedeva, A. A.; Zelchan, R. V.; Chernyshova, A. L.; Kolomiets, L. A.
2016-08-01
The purpose of the study was to evaluate the feasibility of using 99mTc-Al2O3-based radiopharmaceutical, a novel molecular imaging agent for sentinel lymph node detection in patients with invasive cervical cancer. The study included 23 cervical cancer patients (T1aNxMx-T2bNxMx) treated at the Tomsk Cancer Research Institute. In the 18 hours before surgery, 80 MBq of the 99mTc-Al2O3 in peritumoral injected, followed by single-photon emission computed tomography (SPECT) of the pelvis and intraoperative SLN identification. Twenty-seven SLNs were detected by SPECT, and 34 SLNs were identified by intraoperative gamma probe. The total number of identified SLNs per patient ranged from 1 to 3 (the mean number of SLNs was 1.4 per patient). The most common site for SLN detection was the external iliac region (57.2%), followed by the internal iliac (14%), obturator (14%), presacral and retrosacral regions (14%), and the parametrial region (1%). Sensitivity in detecting SLNs was 100% for intraoperative SLN identification and 79% for SPECT image.
A Green Synthesis of Carbon Nanoparticle from Honey for Real-Time Photoacoustic Imaging.
Wu, Lina; Cai, Xin; Nelson, Kate; Xing, Wenxin; Xia, Jun; Zhang, Ruiying; Stacy, Allen J; Luderer, Micah; Lanza, Gregory M; Wang, Lihong V; Shen, Baozhong; Pan, Dipanjan
2013-01-01
Imaging sentinel lymph nodes (SLN) could provide us with critical information about the progression of a cancerous disease. Real-time high-resolution intraoperative photoacoustic imaging (PAI) in conjunction with a near infrared (NIR) probe may offer the opportunities for the immediate imaging for direct identification and resection of SLN or collecting tissue samples. In this work a commercially amenable synthetic methodology is revealed for developing luminescent carbon nanoparticles with rapid clearance properties. A one-pot "green" technique is pursued, which involved rapid surface passivation of carbon nanoparticles with organic macromolecules (e.g. polysorbate, polyethyleneglycol) in a solvent free condition. Interestingly, the naked carbon nanoparticles are derived for the first time, from commercial food grade honey. Surface coated particles are markedly smaller (~7 nm) than the previously explored particles (gold, SWNT, copper) for SLN imaging. Results indicate an exceptionally rapid signal enhancement (~2 min) of the SLN. Owing to their strong optical absorption in the near infrared region, tiny size and rapid lymphatic transport, this platform offers great potential for faster resection of SLN and may lower complications caused by axillary investigation for mismarking with dyes or low-resolution imaging techniques.
The use of {sup 99m}Tc-Al{sub 2}O{sub 3} for detection of sentinel lymph nodes in breast cancer
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sinilkin, I., E-mail: sinilkinig@oncology.tomsk.ru; Chernov, V.; Medvedeva, A.
2016-08-02
Purpose: to study the feasibility of using the new radiopharmaceutical based on the technetium-99m-labeled gamma-alumina for identification of sentinel lymph nodes (SLNs) in breast cancer patients. The study included two groups of breast cancer patients who underwent single photon emission computed tomography (SPECT) and intraoperaive gamma probe identification of sentinel lymph nodes (SLNs). To identify SLNs, the day before surgery Group I patients (n = 34) were injected with radioactive {sup 99m}Tc-Al{sub 2}O{sub 3}, and Group II patients (n = 30) received {sup 99m}Tc-labeled phytate colloid. A total of 37 SLNs were detected in Group I patients. The number ofmore » identified SLNs per patient ranged from 1 to 2 (the average number of identified SLNs was 1.08). Axillary lymph nodes were the most common site of SLN localization. 18 hours after {sup 99m}Tc-Al{sub 2}O{sub 3} injection, the percentage of its accumulation in the SLN was 7–11% (of the counts in the injection site) by SPECT and 17–31% by gamma probe detection. In Group II SLNs were detected in 27 patients. 18 hours after injection of the phytate colloid the percentage of its accumulation in the SLN was 1.5–2% out of the counts in the injection site by SPECT and 4–7% by gamma probe. The new radiopharmaceutical based on the {sup 99m}Tc-Al{sub 2}O{sub 3} demonstrates high accumulation in SLNs without redistribution through the entire lymphatic basin. The sensitivity and specificity of {sup 99m}Tc-Al{sub 2}O{sub 3} were 100% for both SPECT and intraoperative gamma probe identification.« less
Clinical utilities and biological characteristics of melanoma sentinel lymph nodes
Han, Dale; Thomas, Daniel C; Zager, Jonathan S; Pockaj, Barbara; White, Richard L; Leong, Stanley PL
2016-01-01
An estimated 73870 people will be diagnosed with melanoma in the United States in 2015, resulting in 9940 deaths. The majority of patients with cutaneous melanomas are cured with wide local excision. However, current evidence supports the use of sentinel lymph node biopsy (SLNB) given the 15%-20% of patients who harbor regional node metastasis. More importantly, the presence or absence of nodal micrometastases has been found to be the most important prognostic factor in early-stage melanoma, particularly in intermediate thickness melanoma. This review examines the development of SLNB for melanoma as a means to determine a patient’s nodal status, the efficacy of SLNB in patients with melanoma, and the biology of melanoma metastatic to sentinel lymph nodes. Prospective randomized trials have guided the development of practice guidelines for use of SLNB for melanoma and have shown the prognostic value of SLNB. Given the rapidly advancing molecular and surgical technologies, the technical aspects of diagnosis, identification, and management of regional lymph nodes in melanoma continues to evolve and to improve. Additionally, there is ongoing research examining both the role of SLNB for specific clinical scenarios and the ways to identify patients who may benefit from completion lymphadenectomy for a positive SLN. Until further data provides sufficient evidence to alter national consensus-based guidelines, SLNB with completion lymphadenectomy remains the standard of care for clinically node-negative patients found to have a positive SLN. PMID:27081640
Azghadi, Soheila; Daly, Megan; Mayadev, Jyoti
2016-10-01
Recent randomized trials have led to decreased use of completion axillary lymph node dissection (ALND) in early-stage breast cancer patients with a positive sentinel lymph node (SLN), causing controversy surrounding radiotherapy coverage of the axilla. We investigated the practice variation among radiation oncologists for regional nodal coverage for clinicopathologic scenarios and evaluated axillary field design decision-making processes. A customized, web-based questionnaire was e-mailed to 983 community (n = 617) and academic (n = 366) radiation oncologists with a breast cancer subspecialty practicing in the United States. The survey consisted of 18 multiple-choice questions evaluating general clinical preferences surrounding radiation therapy (RT) field design for patients with early-stage breast cancer and a positive SLN. Seven case scenarios were developed to investigate the field design in the setting of specific clinical and pathologic risk factors. Nodal coverage was classified as standard tangents (STs), high tangents (HTs), STs and a supraclavicular field (SCF), or STs and full axillary coverage (AX). A total of 145 evaluable responses were collected, with a response rate of 15.0%. Of the respondents, 12 (8.3%) reported using completion ALND for patients with 1 to 3 positive SLNs without extracapsular extension (ECE) and 66 (45.5%) performed ALND with 1 to 3 positive SLNs with ECE. For micrometastatic SLNs, with no lymphovascular system invasion, 115 (87.1%) used STs or HTs. The use of neoadjuvant chemotherapy (NAC) influenced RT field design for patients with a positive SLN without ECE, with 64 (48.5%) using STs and SCF or STs and AX treatment without NAC and 94 (70.7%) using SCF and AX after NAC. With macrometastatic SLN involvement, most respondents preferred SCF (45.27%) and AX (45.66%). In contrast, for micrometastatic involvement, HTs (43.61%) were frequently chosen. Forty (27.8%) reported using online predictive nomograms to predict further axillary involvement, with no difference between the academic and community radiation oncologists (P = .11). In SLN biopsy-positive early-stage breast cancer with omission of completion ALND, axillary RT is increasing used to cover the undissected axilla. Most respondents use SCF or AX for patients with low to intermediate pathologic features. Online prediction nomograms are used by a few practitioners to assist in clinical decision-making in this setting. Copyright © 2016 Elsevier Inc. All rights reserved.
Preclinical Evaluation of Robotic-Assisted Sentinel Lymph Node Fluorescence Imaging
Liss, Michael A.; Farshchi-Heydari, Salman; Qin, Zhengtao; Hickey, Sean A.; Hall, David J.; Kane, Christopher J.; Vera, David R.
2015-01-01
An ideal substance to provide convenient and accurate targeting for sentinel lymph node (SLN) mapping during robotic-assisted surgery has yet to be found. We used an animal model to determine the ability of the FireFly camera system to detect fluorescent SLNs after administration of a dual-labeled molecular imaging agent. Methods We injected the footpads of New Zealand White rabbits with 1.7 or 8.4 nmol of tilmanocept labeled with 99mTc and a near-infrared fluorophore, IRDye800CW. One and 36 h after injection, popliteal lymph nodes, representing the SLNs, were dissected with the assistance of the FireFly camera system, a fluorescence-capable endoscopic imaging system. After excision of the paraaortic lymph nodes, which represented non-SLNs, we assayed all lymph nodes for radioactivity and fluorescence intensity. Results Fluorescence within all popliteal lymph nodes was easily detected by the FireFly camera system. Fluorescence within the lymph channel could be imaged during the 1-h studies. When compared with the paraaortic lymph nodes, the popliteal lymph nodes retain greater than 95% of the radioactivity at both 1 and 36 h after injection. At both doses (1.7 and 8.4 nmol), the popliteal nodes had higher (P < 0.050) optical fluorescence intensity than the paraaortic nodes at the 1- and 36-h time points. Conclusion The FireFly camera system can easily detect tilmanocept labeled with a near-infrared fluorophore at least 36 h after administration. This ability will permit image acquisition and subsequent verification of fluorescence-labeled SLNs during robotic-assisted surgery. PMID:25024425
Preclinical evaluation of robotic-assisted sentinel lymph node fluorescence imaging.
Liss, Michael A; Farshchi-Heydari, Salman; Qin, Zhengtao; Hickey, Sean A; Hall, David J; Kane, Christopher J; Vera, David R
2014-09-01
An ideal substance to provide convenient and accurate targeting for sentinel lymph node (SLN) mapping during robotic-assisted surgery has yet to be found. We used an animal model to determine the ability of the FireFly camera system to detect fluorescent SLNs after administration of a dual-labeled molecular imaging agent. We injected the footpads of New Zealand White rabbits with 1.7 or 8.4 nmol of tilmanocept labeled with (99m)Tc and a near-infrared fluorophore, IRDye800CW. One and 36 h after injection, popliteal lymph nodes, representing the SLNs, were dissected with the assistance of the FireFly camera system, a fluorescence-capable endoscopic imaging system. After excision of the paraaortic lymph nodes, which represented non-SLNs, we assayed all lymph nodes for radioactivity and fluorescence intensity. Fluorescence within all popliteal lymph nodes was easily detected by the FireFly camera system. Fluorescence within the lymph channel could be imaged during the 1-h studies. When compared with the paraaortic lymph nodes, the popliteal lymph nodes retain greater than 95% of the radioactivity at both 1 and 36 h after injection. At both doses (1.7 and 8.4 nmol), the popliteal nodes had higher (P < 0.050) optical fluorescence intensity than the paraaortic nodes at the 1- and 36-h time points. The FireFly camera system can easily detect tilmanocept labeled with a near-infrared fluorophore at least 36 h after administration. This ability will permit image acquisition and subsequent verification of fluorescence-labeled SLNs during robotic-assisted surgery. © 2014 by the Society of Nuclear Medicine and Molecular Imaging, Inc.
Batistatou, Anna; Cook, Martin G; Massi, Daniela
2009-05-01
In order to survey the diagnostic reporting of melanomas by European pathologists and assess their current practice and opinions on the information required in the final report, a web-based questionnaire was diffused through the members of the Dermatopathology Working Group of the European Society of Pathology. Forty replies from different pathology laboratories were collected (49%). Main prognostic parameters related to the primary tumor, including Breslow thickness, presence of ulceration, and Clark's level, as well as additional features, are reported by a large majority of laboratories. Presence of regression is reported by 90% of respondents but with different recording items. For sentinel lymph node (SLN) biopsy for melanoma, the conventional panel of antibodies includes S-100, Melan A, and HMB45. Dissection of the SLN is performed by "bivalve" or "bread loaf" approach. The number of sections cut and stained varies. Forty-four percent of respondents report depths of metastases from the capsule, while the majority report maximum dimension of the largest deposit. Results indicate that pathology reports for primary cutaneous melanoma and SLN vary between laboratories across Europe. Although the most important prognostic features are universally reported, key features which impact on prognosis and treatment are often omitted and others still require standardization.
Mocellin, Simone; Ambrosi, Alessandro; Montesco, Maria Cristina; Foletto, Mirto; Zavagno, Giorgio; Nitti, Donato; Lise, Mario; Rossi, Carlo Riccardo
2006-08-01
Currently, approximately 80% of melanoma patients undergoing sentinel node biopsy (SNB) have negative sentinel lymph nodes (SLNs), and no prediction system is reliable enough to be implemented in the clinical setting to reduce the number of SNB procedures. In this study, the predictive power of support vector machine (SVM)-based statistical analysis was tested. The clinical records of 246 patients who underwent SNB at our institution were used for this analysis. The following clinicopathologic variables were considered: the patient's age and sex and the tumor's histological subtype, Breslow thickness, Clark level, ulceration, mitotic index, lymphocyte infiltration, regression, angiolymphatic invasion, microsatellitosis, and growth phase. The results of SVM-based prediction of SLN status were compared with those achieved with logistic regression. The SLN positivity rate was 22% (52 of 234). When the accuracy was > or = 80%, the negative predictive value, positive predictive value, specificity, and sensitivity were 98%, 54%, 94%, and 77% and 82%, 41%, 69%, and 93% by using SVM and logistic regression, respectively. Moreover, SVM and logistic regression were associated with a diagnostic error and an SNB percentage reduction of (1) 1% and 60% and (2) 15% and 73%, respectively. The results from this pilot study suggest that SVM-based prediction of SLN status might be evaluated as a prognostic method to avoid the SNB procedure in 60% of patients currently eligible, with a very low error rate. If validated in larger series, this strategy would lead to obvious advantages in terms of both patient quality of life and costs for the health care system.
Can Breast Cancer Biopsy Influence Sentinel Lymph Node Status?
Giuliani, Michela; Patrolecco, Federica; Rella, Rossella; Di Giovanni, Silvia Eleonora; Infante, Amato; Rinaldi, Pierluigi; Romani, Maurizio; Mulè, Antonino; Arciuolo, Damiano; Belli, Paolo; Bonomo, Lorenzo
2016-12-01
We evaluated whether the needle size could influence metastasis occurrence in the axillary sentinel lymph node (SLN) in ultrasound-guided core needle biopsy (US-CNB) of breast cancer (BC). The data from all patients with breast lesions who had undergone US-CNB at our institution from January 2011 to January 2015 were retrospectively reviewed. A total of 377 BC cases were included using the following criteria: (1) percutaneous biopsy-proven invasive BC; and (2) SLN dissection with histopathologic examination. The patients were divided into 2 groups according to the needle size used: 14 gauge versus 16 or 18 gauge. SLN metastasis classification followed the 7th American Joint Committee on Cancer (2010) TNM pathologic staging factors: macrometastases, micrometastases, isolated tumor cells, or negative. Only macrometastases and micrometastases were considered positive, and the positive and negative rates were calculated for the overall population and for both needle size groups. Of the 377 BC cases, 268 US-CNB procedures were performed using a 14-gauge needle and 109 with a 16- or 18-gauge needle, respectively. The negative rate was significantly related statistically with the needle size, with a greater prevalence in the 14-gauge group on both extemporaneous analysis (P = .019) and definitive analysis (P = .002). The macrometastasis rate was 17% (63 of 377) for the 14-gauge and 3% (12 of 377) for the 16- and 18-gauge needles, respectively. Our preliminary results have suggested that use of a large needle size in CNB does not influence SLN status; thus, preoperative breast biopsy can be considered a safe procedure in the diagnosis of malignant breast lesions. Copyright © 2016 Elsevier Inc. All rights reserved.
Lees, John E; Bugby, Sarah L; Jambi, Layal K; Perkins, Alan C
2016-01-01
Objective: The hybrid gamma camera (HGC) has been developed to enhance the localization of radiopharmaceutical uptake in targeted tissues during surgical procedures such as sentinel lymph node (SLN) biopsy. To assess the capability of the HGC, a lymph node contrast (LNC) phantom was constructed to simulate medical scenarios of varying radioactivity concentrations and SLN size. Methods: The phantom was constructed using two clear acrylic glass plates. The SLNs were simulated by circular wells of diameters ranging from 10 to 2.5 mm (16 wells in total) in 1 plate. The second plate contains four larger rectangular wells to simulate tissue background activity surrounding the SLNs. The activity used to simulate each SLN ranged between 4 and 0.025 MBq. The activity concentration ratio between the background and the activity injected in the SLNs was 1 : 10. The LNC phantom was placed at different depths of scattering material ranging between 5 and 40 mm. The collimator-to-source distance was 120 mm. Image acquisition times ranged from 60 to 240 s. Results: Contrast-to-noise ratio analysis and full-width-at-half-maximum (FWHM) measurements of the simulated SLNs were carried out for the images obtained. Over the range of activities used, the HGC detected between 87.5 and 100% of the SLNs through 20 mm of scattering material and 75–93.75% of the SLNs through 40 mm of scattering material. The FWHM of the detected SLNs ranged between 11.93 and 14.70 mm. Conclusion: The HGC is capable of detecting low accumulation of activity in small SLNs, indicating its usefulness as an intraoperative imaging system during surgical SLN procedures. Advances in knowledge: This study investigates the capability of a novel small-field-of-view (SFOV) HGC to detect low activity uptake in small SLNs. The phantom and procedure described are inexpensive and could be easily replicated and applied to any SFOV camera, to provide a comparison between systems with clinically relevant results. PMID:27537079
Riber-Hansen, Rikke; Hastrup, Nina; Clemmensen, Ole; Behrendt, Nille; Klausen, Siri; Ramsing, Mette; Spaun, Eva; Hamilton-Dutoit, Stephen Jacques; Steiniche, Torben
2012-02-01
Metastasis size in melanoma sentinel lymph nodes (SLNs) is an emerging prognostic factor. Two European melanoma treatment trials include SLN metastasis diameters as inclusion criteria. Whilst diameter estimates are sensitive to the number of sections examined, the level of this bias is largely unknown. We performed a prospective multicentre study to compare the European Organisation for Research and Treatment of Cancer (EORTC) recommended protocol with a protocol of complete step-sectioning. One hundred and thirty-three consecutive SLNs from seven SLN centres were analysed by five central sections 50μm apart (EORTC Protocol) followed by complete 250μm step-sectioning. Overall, 29 patients (21.8%) were SLN-positive. The EORTC Protocol missed eight of these metastases (28%), one metastasis measuring less than 0.1mm in diameter, seven measuring between 0.1 and 1mm. Complete step-sectioning at 250μm intervals (Extensive Protocol) missed one metastasis (3%) that measured less than 0.1mm. Thirteen treatment courses (34%) performed if inclusion was based on the Combined Protocol would not be performed if assessed by the EORTC Protocol. Thus, 10 patients would be without completion lymph node dissection (EORTC MINITUB study), whilst three patients would not be eligible for anti-CTLA4 trial (EORTC protocol 18071). The corresponding number with the Extensive Protocol would be three; one patient for the MINITUB registration study and two patients for the anti-CTLA4 study. Examining SLNs by close central sectioning alone (EORTC Protocol) misses a substantial number of metastases and underestimates the maximum metastasis diameter, leading to important changes in patient eligibility for various treatment protocols. Copyright © 2011 Elsevier Ltd. All rights reserved.
Sentinel Lymph Node Detection Using Carbon Nanoparticles in Patients with Early Breast Cancer
Lu, Jianping; Zeng, Yi; Chen, Xia; Yan, Jun
2015-01-01
Purpose Carbon nanoparticles have a strong affinity for the lymphatic system. The purpose of this study was to evaluate the feasibility of sentinel lymph node biopsy using carbon nanoparticles in early breast cancer and to optimize the application procedure. Methods Firstly, we performed a pilot study to demonstrate the optimized condition using carbon nanoparticles for sentinel lymph nodes (SLNs) detection by investigating 36 clinically node negative breast cancer patients. In subsequent prospective study, 83 patients with clinically node negative breast cancer were included to evaluate SLNs using carbon nanoparticles. Another 83 SLNs were detected by using blue dye. SLNs detection parameters were compared between the methods. All patients irrespective of the SLNs status underwent axillary lymph node dissection for verification of axillary node status after the SLN biopsy. Results In pilot study, a 1 ml carbon nanoparticles suspension used 10–15min before surgery was associated with the best detection rate. In subsequent prospective study, with carbon nanoparticles, the identification rate, accuracy, false negative rate was 100%, 96.4%, 11.1%, respectively. The identification rate and accuracy were 88% and 95.5% with 15.8% of false negative rate using blue dye technique. The use of carbon nanoparticles suspension showed significantly superior results in identification rate (p = 0.001) and reduced false-negative results compared with blue dye technique. Conclusion Our study demonstrated feasibility and accuracy of using carbon nanoparticles for SLNs mapping in breast cancer patients. Carbon nanoparticles are useful in SLNs detection in institutions without access to radioisotope. PMID:26296136
Portable widefield imaging device for ICG-detection of the sentinel lymph node
NASA Astrophysics Data System (ADS)
Govone, Angelo Biasi; Gómez-García, Pablo Aurelio; Carvalho, André Lopes; Capuzzo, Renato de Castro; Magalhães, Daniel Varela; Kurachi, Cristina
2015-06-01
Metastasis is one of the major cancer complications, since the malignant cells detach from the primary tumor and reaches other organs or tissues. The sentinel lymph node (SLN) is the first lymphatic structure to be affected by the malignant cells, but its location is still a great challenge for the medical team. This occurs due to the fact that the lymph nodes are located between the muscle fibers, making it visualization difficult. Seeking to aid the surgeon in the detection of the SLN, the present study aims to develop a widefield fluorescence imaging device using the indocyanine green as fluorescence marker. The system is basically composed of a 780nm illumination unit, optical components for 810nm fluorescence detection, two CCD cameras, a laptop, and dedicated software. The illumination unit has 16 diode lasers. A dichroic mirror and bandpass filters select and deliver the excitation light to the interrogated tissue, and select and deliver the fluorescence light to the camera. One camera is responsible for the acquisition of visible light and the other one for the acquisition of the ICG fluorescence. The software developed at the LabVIEW® platform generates a real time merged image where it is possible to observe the fluorescence spots, related to the lymph nodes, superimposed at the image under white light. The system was tested in a mice model, and a first patient with tongue cancer was imaged. Both results showed the potential use of the presented fluorescence imaging system assembled for sentinel lymph node detection.
Pasquali, Sandro; Mocellin, Simone; Mozzillo, Nicola; Maurichi, Andrea; Quaglino, Pietro; Borgognoni, Lorenzo; Solari, Nicola; Piazzalunga, Dario; Mascheroni, Luigi; Giudice, Giuseppe; Patuzzo, Roberto; Caracò, Corrado; Ribero, Simone; Marone, Ugo; Santinami, Mario; Rossi, Carlo Riccardo
2014-03-20
We investigated whether the nonsentinel lymph node (NSLN) status in patients with melanoma improves the prognostic accuracy of common staging features; then we formulated a proposal for including the NSLN status in the current melanoma staging system. We retrospectively collected the clinicopathologic data of 1,538 patients with positive SLN status who underwent completion lymph node dissection (CLND) at nine Italian centers. Multivariable Cox regression survival analysis was used to identify independent prognostic factors. Literature meta-analysis was used to summarize the available evidence on the prognostic value of the NSLN status in patients with positive SLN. NSLN metastasis was observed in 353 patients (23%). After a median follow-up of 45 months, NSLN status was an independent prognostic factor for melanoma-specific survival (hazard ratio [HR] = 1.34; 95% CI, 1.18 to 1.52; P < .001). NSLN status efficiently stratified the prognosis of patients with two to three positive lymph nodes (n = 387; HR = 1.39; 95% CI, 1.07 to 1.81; P = .013), independently of other staging features. Searching the literature, this patient subgroup was investigated in other two studies. Pooling the results (n = 620 patients; 284 NSLN negative and 336 NSLN positive), we found that NSLN status is a highly significant prognostic factor (summary HR = 1.59; 95% CI, 1.27 to 1.98; P < .001) in patients with two to three positive lymph nodes. These findings support the independent prognostic value of the NSLN status in patients with two to three positive lymph nodes, suggesting that this information should be considered for the routine staging in patients with melanoma.
Ji, Yinan; Luo, Ningbin; Jiang, Yi; Li, Qiuyun; Wei, Wei; Yang, Huawei; Liu, Jianlun
2017-07-01
Indocyanine green (ICG) is widely used as a tracer in sentinel lymph node biopsy (SLNB) of patients with breast cancer. Whether SLNB performance can be improved by supplementing ICG with methylene blue dye remains controversial. This study compared the performance of SLNB when ICG was used alone or with blue dye. Consecutive patients with T1-3 primary breast cancer at our hospital were recruited into our study and randomized to undergo SLNB with ICG alone (n = 62) or with the combination of ICG and blue dye (n = 65). We compared the two methods in terms of identification rate, number and detection time of sentinel lymph nodes (SLNs) removed. SLN identification rate were similar in the absence (95.2%) or presence of blue dye (98.5%, P = 0.578) but significantly, more average nodes were removed when blue dye was used (3.8 ± 1.5 versus 2.7 ± 1.2, P = 0.000), and the average time for detecting each SLN was significantly shorter (3.91 ± 1.87 versus 5.65 ± 2.95 min; P = 0.000). No patient in the study experienced severe adverse reactions or complications. Recurrence of axillary node was detected in one patient (1.6%) using ICG alone but not in any patients using ICG and blue dye. The efficiency and sensitivity of SLNB can be improved by combining ICG with blue dye. Copyright © 2017 Elsevier Inc. All rights reserved.
A Google Glass navigation system for ultrasound and fluorescence dual-mode image-guided surgery
NASA Astrophysics Data System (ADS)
Zhang, Zeshu; Pei, Jing; Wang, Dong; Hu, Chuanzhen; Ye, Jian; Gan, Qi; Liu, Peng; Yue, Jian; Wang, Benzhong; Shao, Pengfei; Povoski, Stephen P.; Martin, Edward W.; Yilmaz, Alper; Tweedle, Michael F.; Xu, Ronald X.
2016-03-01
Surgical resection remains the primary curative intervention for cancer treatment. However, the occurrence of a residual tumor after resection is very common, leading to the recurrence of the disease and the need for re-resection. We develop a surgical Google Glass navigation system that combines near infrared fluorescent imaging and ultrasonography for intraoperative detection of sites of tumor and assessment of surgical resection boundaries, well as for guiding sentinel lymph node (SLN) mapping and biopsy. The system consists of a monochromatic CCD camera, a computer, a Google Glass wearable headset, an ultrasonic machine and an array of LED light sources. All the above components, except the Google Glass, are connected to a host computer by a USB or HDMI port. Wireless connection is established between the glass and the host computer for image acquisition and data transport tasks. A control program is written in C++ to call OpenCV functions for image calibration, processing and display. The technical feasibility of the system is tested in both tumor simulating phantoms and in a human subject. When the system is used for simulated phantom resection tasks, the tumor boundaries, invisible to the naked eye, can be clearly visualized with the surgical Google Glass navigation system. This system has also been used in an IRB approved protocol in a single patient during SLN mapping and biopsy in the First Affiliated Hospital of Anhui Medical University, demonstrating the ability to successfully localize and resect all apparent SLNs. In summary, our tumor simulating phantom and human subject studies have demonstrated the technical feasibility of successfully using the proposed goggle navigation system during cancer surgery.
NASA Astrophysics Data System (ADS)
Kuwahata, Akihiro; Kaneko, Miki; Chikaki, Shinichi; Kusakabe, Moriaki; Sekino, Masaki
2018-05-01
The developed device with electromagnetic coils and small permanent magnets quantifies the iron contents of superparamagnetic iron oxide nanoparticles for sentinel lymph node (SLN) biopsy. To remove diamagnetic and paramagnetic components and detect only superparamagnetic components, a 2nd harmonics signal is detected by a gradiometer under a moderate AC magnetic field (1-2 mT) with the fundamental frequency (2.944 kHz) of the coils and DC magnetic field (1-2 mT) of the magnets. The detection limit with a signal-to-noise ratio of 5 is approximately 0.28 μg of iron, and the device has a wide dynamic range of 104, 0.28 μg-2.8 mg. Additional coils and permanent magnets play an important role producing the optimum distribution of AC/DC magnetic fields for an iron distribution-independent and SLN size-independent quantification. We demonstrated the quantification of the iron in phantoms, which have a size of 3-20 mm with varied iron distributions and contain magnetic nanoparticles numerically. These results indicate that the developed device is useful for quantifying the magnetic nanoparticles accumulating in SLNs.
NASA Astrophysics Data System (ADS)
Park, Hye Sun; Nam, Sang Hwan; Kim, Jongwoo; Shin, Hyung Seon; Suh, Yung Doug; Hong, Kwan Soo
2016-06-01
The significance of lymphatic system has gathered great attention for immunotechnology related to cancer metastasis and immunotherapy. To develop innovative immunodiagnostics and immunotherapy in in vivo environments, it is very important to understand excretion pathways and clearance of injected cargoes. Herein, we employed Tm3+-doped upconverting nanoparticles (UCNPs) with versatile advantages suitable for long-term non-invasive in vivo optical imaging and tracking. Transport and retention of the UCNPs in the lymphatic system were evaluated with high-quality NIR-to-NIR upconversion luminescence (UCL) imaging. We obtained their kinetic luminescence profiles for the injection site and sentinel lymph node (SLN) and observed luminescence signals for one month; we also examined UCL images in SLN tissues, organs, and faeces at each time point. We speculate that the injected UCNPs in a footpad of a small mouse are transported rapidly from the lymphatic system to the blood system and then eventually result in an efficient excretion by the hepatobiliary route. These results will support development of novel techniques for SLN biopsy as well as immunotechnology.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sinilkin, I. G.; Chernov, V. I.; Medvedeva, A. A.
The purpose of the study was to evaluate the feasibility of using {sup 99m}Tc-Al{sub 2}O{sub 3}-based radiopharmaceutical, a novel molecular imaging agent for sentinel lymph node detection in patients with invasive cervical cancer. The study included 23 cervical cancer patients (T1aNxMx-T2bNxMx) treated at the Tomsk Cancer Research Institute. In the 18 hours before surgery, 80 MBq of the {sup 99m}Tc-Al{sub 2}O{sub 3} in peritumoral injected, followed by single-photon emission computed tomography (SPECT) of the pelvis and intraoperative SLN identification. Twenty-seven SLNs were detected by SPECT, and 34 SLNs were identified by intraoperative gamma probe. The total number of identified SLNsmore » per patient ranged from 1 to 3 (the mean number of SLNs was 1.4 per patient). The most common site for SLN detection was the external iliac region (57.2%), followed by the internal iliac (14%), obturator (14%), presacral and retrosacral regions (14%), and the parametrial region (1%). Sensitivity in detecting SLNs was 100% for intraoperative SLN identification and 79% for SPECT image.« less
NASA Astrophysics Data System (ADS)
Wang, D.; Qian, J.; Cai, F.; He, S.; Han, S.; Mu, Y.
2012-06-01
In this paper, PbS semiconductor quantum dots (QDs) with near-infrared (NIR) photoluminescence were synthesized in oleic acid and paraffin liquid mixture by using an easily handled and ‘green’ approach. Surface functionalization of the QDs was accomplished with a silica and polyethylene glycol (PEG) phospholipid dual-layer coating and the excellent chemical stability of the nanoparticles is demonstrated. We then successfully applied the ultrastable PbS QDs to in vivo sentinel lymph node (SLN) mapping of mice. Histological analyses were also carried out to ensure that the intravenously injected nanoparticles did not produce any toxicity to the organism of mice. These experimental results suggested that our ultrastable NIR PbS QDs can serve as biocompatible and efficient probes for in vivo optical bioimaging and has great potentials for disease diagnosis and clinical therapies in the future.
Kamiński, Jan P; Case, Doug; Howard-McNatt, Marissa; Geisinger, Kim R; Levine, Edward A
2010-11-01
Sentinel lymph node (SLN) biopsy is now standard of care for breast cancer patients. Intraoperative imprint cytology (IIC) provides results to the surgeon, which may lead to a lymphadenectomy under the same anesthetic when it is positive for metastases. Thus, a positive IIC can spare the patient a second operation and the charges associated with it. The aim of this study is to assess the cost effectiveness of IIC in breast cancer patients. This study evaluated 98 patients who underwent a SLN biopsy between July 2008 and May 2009. The patients were divided into 1 of 3 groups based on the results of IIC and permanent sections: (1) true-negative (TN) IIC, (2) true-positive (TP) IIC, and (3) false-negative (FN) IIC. Total charges for each patient were extracted retrospectively, and nonparametric tests assessed differences in the charges between the three groups. The median total charges per patient for each population were the following: (1) $14,764.62, (2) $19,025.89, and (3) $29,750.64 (P < 0.05). A difference of more than $10,000 exists in total charges per patient between the node-positive population who did not benefit from IIC (FN) and the node-positive population who did benefit from IIC (TP). IIC is a cost-effective evaluation of breast cancer patients. The difference in total charges between the FN and TP groups outweighs the cost of the IIC. In addition to the reduced costs incurred by the patient and the hospital, IIC spares the patient the psychological and physical stress of a second operation.
NASA Astrophysics Data System (ADS)
Qin, Zhengtao
Molecular imaging is visualizations and measurements of in vivo biological processes at the molecular or cellular level using specific imaging probes. As an emerging technology, biocompatible macromolecular or nanoparticle based targeted imaging probes have gained increasing popularities. Those complexes consist of a carrier, an imaging reporter, and a targeting ligand. The active targeting ability dramatically increases the specificity. And the multivalency effect may further reduce the dose while providing a decent signal. In this thesis, sentinel lymph node (SLN) mapping and cancer imaging are two research topics. The focus is to develop molecular imaging probes with high specificity and sensitivity, for Positron Emission Tomography (PET) and optical imaging. The objective of this thesis is to explore dextran radiopharmaceuticals and porous silicon nanoparticles based molecular imaging agents. Dextran polymers are excellent carriers to deliver imaging reporters or therapeutic agents due to its well established safety profile and oligosaccharide conjugation chemistry. There is also a wide selection of dextran polymers with different lengths. On the other hand, Silicon nanoparticles represent another class of biodegradable materials for imaging and drug delivery. The success in fluorescence lifetime imaging and enhancements of the immune activation potency was briefly discussed. Chapter 1 begins with an overview on current molecular imaging techniques and imaging probes. Chapter 2 presents a near-IR dye conjugated probe, IRDye 800CW-tilmanocept. Fluorophore density was optimized to generate the maximum brightness. It was labeled with 68Ga and 99mTc and in vivo SLN mapping was successfully performed in different animals, such as mice, rabbits, dogs and pigs. With 99mTc labeled IRDye 800CW-tilmanocept, chapter 3 introduces a two-day imaging protocol with a hand-held imager. Chapter 4 proposed a method to dual radiolabel the IRDye 800CW-tilmanocept with both 68Ga and 99mTc. Chapter 5 introduces a 68Ga metal chelating bioorthogonal tetrazine dextran probe for multistep imaging of a colon cancer. Chapter 6 presents the synthesis and in vivo evaluation of a Hepatocellular Carcinoma targeting PET probe 68Ga-Insulin-Dextran. Chapter 7 discusses a novel method to prepare silicon nanoparticles with great yield and size control. The last chapter 8 concludes all probes developed in this thesis and their clinical relevance.
In vivo lymph node mapping by Cadmium Tellurium quantum dots in rats.
Si, Chengshuai; Zhang, Yunpeng; Lv, Xianbo; Yang, Wuli; Ran, Zhipeng; Sun, Peng
2014-12-01
Intraoperative lymph node mapping (LNM) is highly significant for many surgeries in patients with cancer. Many types of tracers are currently used, but the ideal method has not yet been identified. We aimed to identify a stable lymphatic drainage pathway in an animal model and compared the effects of quantum dots (QD), a new fluorescent tracer, with those of methylene blue in intraoperative LNM. Indian ink (0.2 mL) was subcutaneously injected into the plantar metatarsal regions of six Sprague-Dawley rats. After 2 wk of incubation and subsequent dissection, the potentially stained LNs were examined pathologically to identify the lymphatic drainage pathway. After applying anesthesia, 0.1 mL methylene blue (2%) and QD (1 mg/mL) were injected into the plantar metatarsal regions of six rats for intraoperative LNM. The QD group was observed with a near-infrared imaging system, and the methylene blue group was directly observed. Drainages were recorded at 5, 10, 30, 60, and 120 min and at 1 d. Two three-level drainage pathways, that is, a peripheral drainage (popliteal LNs, inguinal LNs, and axillary LNs) and a central drainage (popliteal lymph node [LN], iliac LN, and renal LN) pathways were identified. Both methylene blue and QD stained the sentinel lymph node (SLNs) quickly, but methylene blue was difficult to identify in the deep tissues and the LNs beyond the SLN. Furthermore, the blue-stained LNs remain dyed for only 2 h. In contrast, the QDs exhibited high target-to-background ratios in both the SLNs and the following LNs. Additionally, the fluorescence lasted from 5 min-1 d after injection. An ideal lymphatic drainage model was found. QDs are excellent tracers for intraoperative LNM compared with methylene blue. Near infrared fluorescent imaging is a promising LNM method for clinical practice. Copyright © 2014 Elsevier Inc. All rights reserved.
Lützen, Ulf; Naumann, Carsten Maik; Marx, Marlies; Zhao, Yi; Jüptner, Michael; Baumann, René; Papp, László; Zsótér, Norbert; Aksenov, Alexey; Jünemann, Klaus-Peter; Zuhayra, Maaz
2016-09-07
Because of the increasing importance of computer-assisted post processing of image data in modern medical diagnostic we studied the value of an algorithm for assessment of single photon emission computed tomography/computed tomography (SPECT/CT)-data, which has been used for the first time for lymph node staging in penile cancer with non-palpable inguinal lymph nodes. In the guidelines of the relevant international expert societies, sentinel lymph node-biopsy (SLNB) is recommended as a diagnostic method of choice. The aim of this study is to evaluate the value of the afore-mentioned algorithm and in the clinical context the reliability and the associated morbidity of this procedure. Between 2008 and 2015, 25 patients with invasive penile cancer and inconspicuous inguinal lymph node status underwent SLNB after application of the radiotracer Tc-99m labelled nanocolloid. We recorded in a prospective approach the reliability and the complication rate of the procedure. In addition, we evaluated the results of an algorithm for SPECT/CT-data assessment of these patients. SLNB was carried out in 44 groins of 25 patients. In three patients, inguinal lymph node metastases were detected via SLNB. In one patient, bilateral lymph node recurrence of the groins occurred after negative SLNB. There was a false-negative rate of 4 % in relation to the number of patients (1/25), resp. 4.5 % in relation to the number of groins (2/44). Morbidity was 4 % in relation to the number of patients (1/25), resp. 2.3 % in relation to the number of groins (1/44). The results of computer-assisted assessment of SPECT/CT data for sentinel lymph node (SLN)-diagnostics demonstrated high sensitivity of 88.8 % and specificity of 86.7 %. SLNB is a very reliable method, associated with low morbidity. Computer-assisted assessment of SPECT/CT data of the SLN-diagnostics shows high sensitivity and specificity. While it cannot replace the assessment by medical experts, it can still provide substantial supplement and assistance.
Emile, Sameh H; Elfeki, Hossam; Shalaby, Mostafa; Sakr, Ahmad; Sileri, Pierpaolo; Laurberg, Søren; Wexner, Steven D
2017-11-01
This review aimed to determine the overall sensitivity and specificity of indocyanine green (ICG) near-infrared (NIR) fluorescence in sentinel lymph node (SLN) detection in Colorectal cancer (CRC). A systematic search in electronic databases was conducted. Twelve studies including 248 patients were reviewed. The median sensitivity, specificity, and accuracy rates were 73.7, 100, and 75.7. The pooled sensitivity and specificity rates were 71% and 84.6%. In conclusion, ICG-NIR fluorescence is a promising technique for detecting SLNs in CRC. © 2017 Wiley Periodicals, Inc.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stauder, Michael C., E-mail: mstauder@mdanderson.org; Caudle, Abigail S.; Allen, Pamela K.
Purpose: We sought to determine the rate of postmastectomy radiation therapy (PMRT) among women treated with axillary lymph node dissection (ALND) after positive sentinel lymph node (SLN) biopsy results and to establish the effect of negative ALND results and PMRT on locoregional recurrence (LRR) and overall survival (OS). Methods and Materials: All patients were treated with mastectomy and ALND after positive SLN biopsy results. All patients had clinical N0 or NX disease at the time of mastectomy and received no neoadjuvant therapy. The presence of lymphovascular space invasion, presence of multifocality, number of positive SLNs and non-SLNs, clinical and pathologicmore » stage, extranodal extension, age, and use of PMRT were evaluated for significance regarding the rates of OS and LRR. Results: A total of 345 patients were analyzed. ALND after positive SLN biopsy results was negative in 235 patients (68.1%), and a total of 112 patients (32.5%) received radiation therapy. On multivariate analysis, only pathologic stage III predicted for lower OS (hazard ratio, 3.32; P<.001). The rate of 10-year freedom from LRR was 87.9% and 95.3% in patients with positive ALND results and patients with negative ALND results, respectively. In patients with negative ALND results with ≥3 positive SLNs, the rate of freedom from LRR was 74.7% compared with 96.7% in those with <3 positive SLNs (P=.009). In patients with negative ALND results, ≥3 positive SLNs predicted for an increase in LRR on multivariate analysis (hazard ratio, 10.10; P=.034). Conclusions: A low proportion of cT1-2, N0 patients with positive SLNs who undergo mastectomy receive PMRT after ALND. Even in this low-risk cohort, patients with ≥3 positive SLNs and negative ALND results are at increased risk of LRR and may benefit from PMRT.« less
Mocellin, Simone; Hoon, Dave S B; Pilati, Pierluigi; Rossi, Carlo R; Nitti, Donato
2007-04-20
Molecular biology-based ultrastaging of cancer is already part of the standard management of patients with hematologic malignancies, whereas the evidence for solid tumors is much more debated. Polymerase chain reaction (PCR) -based detection of melanoma cells in sentinel lymph nodes (SLN) of patients with melanoma represents an appealing prognostic tool. However, no consensus exists on the clinical implementation of this prognostic indicator for the management of these patients. Twenty-two studies enrolling 4,019 patients who underwent SLN biopsy for clinical stage I to II cutaneous melanoma were reviewed. Correlation of PCR status with TNM stage, disease recurrence rates, and survival was assessed by means of association statistics and formal meta-analysis, respectively. PCR status correlated with both TNM stage (stage I to II v III; PCR positivity, 95.1% v 46.6%; P < .0001) and disease recurrence (PCR positive v negative; relapse rate, 16.8% v 8.7%; P < .0001). PCR positivity was also associated with worse overall (hazard ratio [HR], 5.08; 95% CI, 1.83 to 14.08; P = .002) and disease-free (HR, 3.41; 95% CI, 1.86 to 6.24; P < .0001) survival. Statistical heterogeneity was significant, underscoring the variability among overall effect estimates across studies; metaregression and subgroup analysis did not identify clear-cut sources of heterogeneity, although some study design variables were suggested as potential causes. PCR status of SLN appears to have a clinically valuable prognostic power in patients with melanoma. Although the heterogeneity of the studies so far published warrants caution to avoid overestimating the favorable results of pooled data, our findings strongly support additional investigation in this field.
Daniele, Lorenzo; Annaratone, Laura; Allia, Elena; Mariani, Sara; Armando, Enrico; Bosco, Martino; Macrì, Luigia; Cassoni, Paola; D'Armento, Giuseppe; Bussolati, Gianni; Cserni, Gabor; Sapino, Anna
2009-09-01
The optimal pathological assessment of sentinel nodes (SLNs) in breast cancer is a matter of debate. Currently, multilevel histological evaluation and immunohistochemistry (IHC) are recommended, but alternative RT-PCR procedures have been developed. To assess the reliability of these different procedures, we devised a step-sectioning protocol at 100 micron-intervals of 74 SLNs using methacarn fixation. mRNA was extracted from sections collected from levels 4 to 5. Mammaglobin, CEA and CK19 were used for RT-PCR. mRNA extraction was successful in 69 SLNs. Of these, 7 showed macrometastases (>2mm), 2 showed micrometastases (<2 mm) and 7 showed isolated tumour cells (ITC) by IHC. RT-PCR was positive for the three markers in 6 of 7 macrometastases and in 1 of 2 micrometastases. In the 2 RT-PCR negative cases, metastases were detected only on sections distant from those analysed by RT-PCR. CEA and/or CK19 were positive by RT-PCR in 3 of 7 ITC and in 23 morphologically negative SLNs. In conclusion, the main goal of our study was to show that the use of alternate sections of the same sample for different procedures is the key reason for the discrepancies between molecular and morphological analyses of SLN. We believe that only prospective studies with quantitative mRNA analysis of specific metastatic markers on the whole lymph node can elucidate the utility of molecular assessments of SLN.
Solassol, J; Burcia, V; Costes, V; Lacombe, J; Mange, A; Barbotte, E; de Verbizier, D; Cartier, C; Makeieff, M; Crampette, L; Boulle, N; Maudelonde, T; Guerrier, B; Garrel, R
2009-01-01
Background: Molecular diagnosis has been proposed to enhance the intra-operative diagnosis of sentinel lymph node (SLN) invasion in head and neck squamous cell carcinoma (HNSCC). Although cytokeratin (CK) mRNA quantification with real-time reverse transcriptase-PCR (QRT–PCR) has produced encouraging results, the more discriminating markers remain to be identified. Methods: Pemphigus vulgaris antigen (PVA), squamous cell carcinoma antigen (SCCA), and CK17 mRNA were quantified using QRT–PCR, and the results were compared with an extensive histopathological examination of the entire SLNs on 78 SLNs harvested from 22 patients with HNSCC. Results: SCCA and CK17 quantification showed significantly higher mRNA values for macrometastases (MAs) than for either negative or isolated tumour cell (ITC) SLNs (P<0.01). Pemphigus vulgaris antigen allowed the discrimination of all MAs and micrometastases from both negative and ITC SLNs (P<0.001). For the neck staging of patients, considering metastatic vs non-metastatic status, receiver-operating characteristic curve analysis found areas under the curve of 93.8, 97.9, and 100% for CK17, SCCA, and PVA, respectively. With PVA, a cutoff value of 562 copies per 100 ng of cDNA permitted the correct distinction between patients with positive as opposed to negative neck nodes in all cases. Conclusion: PVA seems to be a highly promising marker for accurate intra-operative SLN staging in HNSCC by QRT–PCR. PMID:19997107
2013-01-01
Background Besides being a preferential site of early metastasis, the sentinel lymph node (SLN) is also a privileged site of T-cell priming, and may thus be an appropriate target for investigating cell types involved in antitumor immune reactions. Methods In this retrospective study we determined the prevalence of OX40+ activated T lymphocytes, FOXP3+ (forkhead box P3) regulatory T cells, DC-LAMP+ (dendritic cell-lysosomal associated membrane protein) mature dendritic cells (DCs) and CD123+ plasmacytoid DCs by immunohistochemistry in 100 SLNs from 60 melanoma patients. Density values of each cell type in SLNs were compared to those in non-sentinel nodes obtained from block dissections (n = 37), and analyzed with regard to associations with clinicopathological parameters and disease outcome. Results Sentinel nodes showed elevated amount of all cell types studied in comparison to non-sentinel nodes. Metastatic SLNs had higher density of OX40+ lymphocytes compared to tumor-negative nodes, while no significant difference was observed in the case of the other cell types studied. In patients with positive sentinel node status, high amount of FOXP3+ cells in SLNs was associated with shorter progression-free (P = 0.0011) and overall survival (P = 0.0014), while no significant correlation was found in the case of sentinel-negative patients. The density of OX40+, CD123+ or DC-LAMP+ cells did not show significant association with the outcome of the disease. Conclusions Taken together, our results are compatible with the hypothesis of functional competence of sentinel lymph nodes based on the prevalence of the studied immune cells. The density of FOXP3+ lymphocytes showed association with progression and survival in patients with positive SLN status, while the other immune markers studied did not prove of prognostic importance. These results, together with our previous findings on the prognostic value of activated T cells and mature DCs infiltrating primary melanomas, suggest that immune activation-associated markers in the primary tumor may have a higher impact than those in SLNs on the prognosis of the patients. On the other hand, FOXP3+ cell density in SLNs, but not in the primary tumor, was found predictive of disease outcome in melanoma patients. PMID:23418928
Yamamoto, Maki; Fisher, Kate J; Wong, Joyce Y; Koscso, Jonathan M; Konstantinovic, Monique A; Govsyeyev, Nicholas; Messina, Jane L; Sarnaik, Amod A; Cruse, C Wayne; Gonzalez, Ricardo J; Sondak, Vernon K; Zager, Jonathan S
2015-05-15
Sentinel lymph node biopsy (SLNB) is indicated for the staging of clinically lymph node-negative melanoma of intermediate thickness, but its use is controversial in patients with thick melanoma. From 2002 to 2012, patients with melanoma measuring ≥4 mm in thickness were evaluated at a single institution. Associations between survival and clinicopathologic characteristics were explored. Of 571 patients with melanomas measuring ≥4 mm in thickness and no distant metastases, the median age was 66 years and 401 patients (70.2%) were male. The median Breslow thickness was 6.2 mm; the predominant subtype was nodular (45.4%). SLNB was performed in 412 patients (72%) whereas 46 patients (8.1%) presented with clinically lymph node-positive disease and 113 patients (20%) did not undergo SLNB. A positive SLN was found in 161 of 412 patients (39.1%). For SLNB performed at the study institution, 14 patients with a negative SLNB developed disease recurrence in the mapped lymph node basin (false-negative rate, 12.3%). The median disease-specific survival (DSS), overall survival (OS), and recurrence-free survival (RFS) for the entire cohort were 62.1 months, 42.5 months, and 21.2 months, respectively. The DSS and OS for patients with a negative SLNB were 82.4 months and 53.4 months, respectively; 41.2 months and 34.7 months, respectively, for patients with positive SLNB; and 26.8 months and 22 months, respectively, for patients with clinically lymph node-positive disease (P<.0001). The median RFS was 32.4 months for patients who were SLNB negative, 14.3 months for patients who were SLNB positive, and 6.8 months for patients with clinically lymph node-positive disease (P<.0001). With an acceptably low false-negative rate, patients with thick melanoma and a negative SLNB appear to have significantly prolonged RFS, DSS, and OS compared with those with a positive SLNB. Therefore, SLNB should be considered as indicated for patients with thick, clinically lymph node-negative melanoma. © 2015 American Cancer Society.
NASA Astrophysics Data System (ADS)
Ye, Jinzuo; Chi, Chongwei; Zhang, Shuang; Ma, Xibo; Tian, Jie
2014-02-01
Sentinel lymph node (SLN) in vivo detection is vital in breast cancer surgery. A new near-infrared fluorescence-based surgical navigation system (SNS) imaging software, which has been developed by our research group, is presented for SLN detection surgery in this paper. The software is based on the fluorescence-based surgical navigation hardware system (SNHS) which has been developed in our lab, and is designed specifically for intraoperative imaging and postoperative data analysis. The surgical navigation imaging software consists of the following software modules, which mainly include the control module, the image grabbing module, the real-time display module, the data saving module and the image processing module. And some algorithms have been designed to achieve the performance of the software, for example, the image registration algorithm based on correlation matching. Some of the key features of the software include: setting the control parameters of the SNS; acquiring, display and storing the intraoperative imaging data in real-time automatically; analysis and processing of the saved image data. The developed software has been used to successfully detect the SLNs in 21 cases of breast cancer patients. In the near future, we plan to improve the software performance and it will be extensively used for clinical purpose.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Grivas, Nikolaos, E-mail: n.grivas@nki.nl; Wit, Esther; Pos, Floris
Purpose: To assess the efficacy of robotic-assisted laparoscopic sentinel lymph node (SLN) dissection (SLND) to select those patients with prostate cancer (PCa) who would benefit from additional pelvic external beam radiation therapy and long-term androgen deprivation therapy (ADT). Methods and Materials: Radioisotope-guided SLND was performed in 224 clinically node-negative patients scheduled to undergo external beam radiation therapy. Patients with histologically positive SLNs (pN1) were also offered radiation therapy to the pelvic lymph nodes, combined with 3 years of ADT. Biochemical recurrence (BCR), overall survival, and metastasis-free (including pelvic and nonregional lymph nodes) survival (MFS) rates were retrospectively calculated. The Briganti andmore » Kattan nomogram predictions were compared with the observed pN status and BCR. Results: The median prostate-specific antigen (PSA) value was 15.4 ng/mL (interquartile range [IQR] 8-29). A total number of 834 SLNs (median 3 per patient; IQR 2-5) were removed. Nodal metastases were diagnosed in 42% of the patients, with 150 SLNs affected (median 1; IQR 1-2). The 5-year BCR-free and MFS rates for pN0 patients were 67.9% and 87.8%, respectively. The corresponding values for pN1 patients were 43% and 66.6%. The PSA level and number of removed SLNs were independent predictors of BCR and MFS, and pN status was an additional independent predictor of BCR. The 5-year overall survival rate was 97.6% and correlated only with pN status. The predictive accuracy of the Briganti nomogram was 0.665. Patients in the higher quartiles of Kattan nomogram prediction of BCR had better than expected outcomes. The complication rate from SLND was 8.9%. Conclusions: For radioisotope-guided SLND, the high staging accuracy is accompanied by low morbidity. The better than expected outcomes observed in the lower quartiles of BCR prediction suggest a role for SLN biopsy as a potential selection tool for the addition of pelvic radiation therapy and ADT intensification in pN1 patients.« less
Sentinel lymph node detection in patients with endometrial cancer.
Niikura, Hitoshi; Okamura, Chikako; Utsunomiya, Hiroki; Yoshinaga, Kosuke; Akahira, Junichi; Ito, Kiyoshi; Yaegashi, Nobuo
2004-02-01
The purpose of this study was to examine the feasibility of sentinel lymph node (SLN) detection in patients with endometrial cancer using preoperative lymphoscintigraphy and an intraoperative gamma probe. Between June 2001 and January 2003, 28 consecutive patients with endometrial cancer who were scheduled for total abdominal hysterectomy, bilateral salpingo-oophorectomy, total pelvic lymphadenectomy, and paraaortic lymphadenectomy at Tohoku University School of Medicine underwent sentinel lymph node detection. On the day before surgery, preoperative lymphoscintigraphy was performed by injection of 99m-Technetium ((99m)Tc)-labeled phytate into the endometrium during hysteroscopy. At the time of surgery, a gamma-detecting probe was used to locate radioactive lymph nodes. At least one sentinel node was detected in each of 23 of the 28 patients (82%). The mean number of sentinel nodes detected was 3.1 (range, 1-9). Sentinel nodes could be identified in 21 of 22 patients (95%) whose tumor did not invade more than halfway into the myometrium. Eighteen patients had radioactive nodes in the paraaortic area. Most patients had a sentinel node in one of the following three sites: paraaortic, external iliac, and obturator. The sensitivity and specificity for detecting lymph node metastases were both 100%. The combination of preoperative lymphoscintigraphy with intraoperative gamma probe detection may be useful in identifying sentinel nodes in early-stage endometrial cancer.
Manca, G; Volterrani, D; Mazzarri, S; Duce, V; Svirydenka, A; Giuliano, A; Mariani, G
2014-06-01
Although, like the axilla, the internal mammary nodes (IMNs) are a first-echelon nodal drainage site in breast cancer, the importance of their treatment has long been debated. Seminal randomized trials have failed to demonstrate a survival benefit from surgical IMN dissection, and several retrospective studies have shown that IMNs are rarely the first site of recurrence. However, the recent widespread adoption of sentinel lymph node (SLN) biopsy has stimulated a critical reappraisal of such early results. Furthermore, the higher proportion of screening-detected cancers, improved imaging and techniques (i.e., lymphoscintigraphy for radioguided SLN biopsy) make it possible to visualize lymphatic drainage to the IMNs. The virtually systematic application of adjuvant systemic and/or loco-regional radiotherapy encourages re-examination of the significance of IMN metastases. Moreover, randomized trials testing the value of postmastectomy irradiation and a meta-analysis of 78 randomized trials have provided high levels of evidence that local-regional tumor control is associated with long-term survival improvements. This benefit was limited to trials that used systemic chemotherapy, which was not routinely administered in the earlier studies. However, the contribution from IMN treatment is unclear. Lymphoscintigraphic studies have shown that a significant proportion of breast cancers have primary drainage to the IMNs, including approximately 30% of medial tumors and 15% of lateral tumors. In the few studies where IMN biopsy was performed, 20% of sentinel IMNs were metastatic. The risk of IMN involvement is higher in patients with medial tumors and positive axillary nodes. IMN metastasis has prognostic significance, as recognized by its inclusion in the American Joint Committee on Cancer staging criteria, and seems to have similar prognostic importance as axillary nodal involvement. Although routine IMN evaluation might be indicated, it has not been routinely performed, perhaps because IMN drainage with lymphoscintigraphy is more difficult to demonstrate than axillary drainage. This difference is due to technical reasons and not the absence of lymphatics to the IMN. Recent anatomical studies have confirmed a model of breast lymphatic drainage that comprises superficial, deep and perforating systems. The superficial system drains to the axilla, usually to a lymph node posterior to the pectoralis minor muscle. The deep system drains to the axilla and also anastomoses with the perforating system which drains to the IMNs. The perforating system does not connect with the superficial system. The prevalence of IMN drainage tends to reflect the method of lymphoscintigraphy, where peritumoral (deep lymphatic system) injections have a much higher likelihood of IMN drainage than subareolar or subdermal (superficial lymphatic system) injections. The fused SPECT/CT images represent a further technical solution to increase the identification of IMNs and consequently can significantly reduce the false negative rate of sentinel lymph node biopsy. Before mature results from current and future randomized trials assessing the benefit of IMN irradiation become available, lymphoscintigraphy and IMNs biopsy may be used to guide decisions regarding systemic and local-regional treatment. However, even in patients with visualized primary IMN drainage, the potential benefit of treatment should be balanced against the risk of added morbidity.
Shen, Songjie; Xu, Qianqian; Zhou, Yidong; Mao, Feng; Guan, Jinghong; Sun, Qiang
2018-05-22
There were limited data available for a head-to-head comparison of the identification rate and survival between the combined method of indocyanine green fluorescence and blue dye versus the traditional blue dye alone method for sentinel lymph node (SLN) biopsy. From January 2013 to December 2015, 523 eligible breast cancer patients were included in this nonrandomized prospective analysis. The identification rates, the number of SLNs identified, and the disease-free survival (DFS) between the two mapping methods were compared. The identification rate of SLNs was significantly higher with the combined method than that with the blue dye alone method (99.2% vs 93.3%, respectively; P < 0.001). The average number of SLNs identified per patient in the combined method group was 3.7 ± 2.4, which was more than that in the blue dye alone group (3.2 ± 1.6; P = 0.004). With a median follow-up of 29 months, 0.5% patients in the combined group, and 1.3% patients in the blue dye group had axillary recurrences. The DFS between the two groups showed no significant difference (P = 0.161). The combined method achieved a higher identification rate and lower rate of axillary recurrence compared to the blue dye alone method. © 2018 Wiley Periodicals, Inc.
Sarcolipin overexpression improves muscle energetics and reduces fatigue
Sopariwala, Danesh H.; Pant, Meghna; Shaikh, Sana A.; Goonasekera, Sanjeewa A.; Molkentin, Jeffery D.; Weisleder, Noah; Ma, Jianjie; Pan, Zui
2015-01-01
Sarcolipin (SLN) is a regulator of sarcoendoplasmic reticulum calcium ATPase in skeletal muscle. Recent studies using SLN-null mice have identified SLN as a key player in muscle thermogenesis and metabolism. In this study, we exploited a SLN overexpression (SlnOE) mouse model to determine whether increased SLN level affected muscle contractile properties, exercise capacity/fatigue, and metabolic rate in whole animals and isolated muscle. We found that SlnOE mice are more resistant to fatigue and can run significantly longer distances than wild-type (WT). Studies with isolated extensor digitorum longus (EDL) muscles showed that SlnOE EDL produced higher twitch force than WT. The force-frequency curves were not different between WT and SlnOE EDLs, but at lower frequencies the pyruvate-induced potentiation of force was significantly higher in SlnOE EDL. SLN overexpression did not alter the twitch and force-frequency curve in isolated soleus muscle. However, during a 10-min fatigue protocol, both EDL and soleus from SlnOE mice fatigued significantly less than WT muscles. Interestingly, SlnOE muscles showed higher carnitine palmitoyl transferase-1 protein expression, which could enhance fatty acid metabolism. In addition, lactate dehydrogenase expression was higher in SlnOE EDL, suggesting increased glycolytic capacity. We also found an increase in store-operated calcium entry (SOCE) in isolated flexor digitorum brevis fibers of SlnOE compared with WT mice. These data allow us to conclude that increased SLN expression improves skeletal muscle performance during prolonged muscle activity by increasing SOCE and muscle energetics. PMID:25701006
Li, Jianyi; Jia, Shi; Zhang, Wenhai; Qiu, Fang; Zhang, Yang; Gu, Xi; Xue, Jinqi
2015-06-30
The practice of breast cancer diagnosis and treatment in China varies to that in western developed countries. With the unavailability of radioactive tracer technique for sentinel lymph nodes biopsy (SLNB), using blue dye alone has been the only option in China. Also, the diagnosis of breast malignant tumor in most Chinese centres heavily relies on intraoperative instant frozen histology which is normally followed by sentinel lymph nodes mapping, SLNB and the potential breast and axillary operations in one consecutive session. This practice appears to cause a high false negative rate (FNR) for SLNB. The present study aimed to investigate the impact of the current practice in China on the accuracy of SLNB, and whether partial axillary lymph node dissection (PALND), dissection of lymph nodes inferior to the intercostobrachial nerve (ICBN), was a good complementary procedure following SLNB using blue dye. 289 patients with clinically node-negative breast cancer were identified and recruited. Tumorectomy, intraoperative instant frozen histological diagnosis, SLNB using methylene blue dye, and PALND or complete axillary node dissection (ALND) were performed in one consecutive operative session. The choice of SLNB only, SLNB followed by PALND or by ALND was based on the pre-determined protocol and preoperative choice by the patient. Clinical parameters were analyzed and survival analysis was performed. 37% patients with clinically negative nodes were found nodes positive. 59 patients with positive SLN underwent ALND, including 47 patients with up to two positive nodes which were all located inferior to the ICBN. 9 patients had failed SLNB and underwent PALND. Among them, 3 (33.3%) patients were found to have one metastatic node. 149 patients showed negative SLNB but chose PALND. Among them, 30 (20.1%), 14 (9.4) and 1 (0.7%) patients were found to have one, two and three metastatic node(s), respectively. PALND detected 48 (30.4%) patients who had either failed SLNB or negative SLNB to have additional positive nodes. All the patients with up to two positive nodes had their nodes located inferior to the ICBN. The FNR of SLNB was 43%. The accuracy rate was 58%. The follow-up ranged 12-33 months. The incidence of lymphedema for SLNB, PALND, and ALND was 0%, 0%, and 25.4%, respectively (P < 0.005). The disease-free survivals for SLNB, PALND, and ALND groups were 95.8%, 96.8%, and 94.9%, respectively (p > 0.05). Under the circumstances of current practice in China, PALND is a good complementary procedure following SLNB in clinically node-negative breast cancer.
Re and 99mTc Tricarbonyl Probes for Target-Specific Detection of Melanoma and Sentinel Lymph Node
NASA Astrophysics Data System (ADS)
Morais, Mauricio da Silva
The work described in this thesis aimed at the development of M(I) (M = 99mTc, Re) specific probes for the detection of malignant melanoma and sentinel lymph node (SLN) through the in vivo targeting of membrane receptors. In the former case we have designed M(CO)3-complexes stabilized by tridentate chelators containing a pyrazolyl-diamine chelating unit (N,N,N donor atom set) and pendant alpha-melanocyte-stimulating hormone (alpha-MSH) derivatives for targeting the melanocortin receptor 1 (MC1R), which is overexpressed in melanotic and amelanotic human melanoma cells. (Abstract shortened by ProQuest.). None None None None None None None None None None None None None None None None None
Chu, Liliang; Wang, Shaowei; Li, Kanghui; Xi, Wang; Zhao, Xinyuan; Qian, Jun
2014-01-01
Near-infrared (NIR) imaging technology has been widely used for biomedical research and applications, since it can achieve deep penetration in biological tissues due to less absorption and scattering of NIR light. In our research, polymer nanoparticles with NIR fluorophores doped were synthesized. The morphology, absorption/emission features and chemical stability of the fluorescent nanoparticles were characterized, separately. NIR fluorescent nanoparticles were then utilized as bright optical probes for macro in vivo imaging of mice, including sentinel lymph node (SLN) mapping, as well as distribution and excretion monitoring of nanoparticles in animal body. Furthermore, we applied the NIR fluorescent nanoparticles in in vivo microscopic bioimaging via a confocal microscope. Under the 635 nm-CW excitation, the blood vessel architecture in the ear and the brain of mice, which were administered with nanoparticles, was visualized very clearly. The imaging depth of our one-photon microscopy, which was assisted with NIR fluorescent nanoprobes, can reach as deep as 500 μm. Our experiments show that NIR fluorescent nanoparticles have great potentials in various deep-tissue imaging applications. PMID:25426331
A critical reappraisal of false negative sentinel lymph node biopsy in melanoma.
Manca, G; Romanini, A; Rubello, D; Mazzarri, S; Boni, G; Chiacchio, S; Tredici, M; Duce, V; Tardelli, E; Volterrani, D; Mariani, G
2014-06-01
Lymphatic mapping and sentinel lymph node biopsy (SLNB) have completely changed the clinical management of cutaneous melanoma. This procedure has been accepted worldwide as a recognized method for nodal staging. SLNB is able to accurately determine nodal basin status, providing the most useful prognostic information. However, SLNB is not a perfect diagnostic test. Several large-scale studies have reported a relatively high false-negative rate (5.6-21%), correctly defined as the proportion of false-negative results with respect to the total number of "actual" positive lymph nodes. The main purpose of this review is to address the technical issues that nuclear physicians, surgeons, and pathologists should carefully consider to improve the accuracy of SLNB by minimizing its false-negative rate. In particular, SPECT/CT imaging has demonstrated to be able to identify a greater number of sentinel lymph nodes (SLNs) than those found by planar lymphoscintigraphy. Furthermore, a unique definition in the international guidelines is missing for the operational identification of SLNs, which may be partly responsible for this relatively high false-negative rate of SLNB. Therefore, it is recommended for the scientific community to agree on the radioactive counting rate threshold so that the surgeon can be better radioguided to detect all the lymph nodes which are most likely to harbor metastases. Another possible source of error may be linked to the examination of the harvested SLNs by conventional histopathological methods. A more careful and extensive SLN analysis (e.g. molecular analysis by RT-PCR) is able to find more positive nodes, so that the false-negative rate is reduced. Older age at diagnosis, deeper lesions, histologic ulceration, head-neck anatomical location of primary lesions are the clinical factors associated with false-negative SLNBs in melanoma patients. There is still much controversy about the clinical significance of a false-negative SLNB on the prognosis of melanoma patients. Indeed, most studies have failed to show that there is worse melanoma-specific survival for false-negative compared to true-positive SLNB patients.
Sabel, Michael S.; Rice, John D.; Griffith, Kent A.; Lowe, Lori; Wong, Sandra L.; Chang, Alfred E.; Johnson, Timothy M.; Taylor, Jeremy M.G.
2013-01-01
Introduction To identify melanoma patients at sufficiently low risk of nodal metastases who could avoid SLN biopsy (SLNB). Several statistical models have been proposed based upon patient/tumor characteristics, including logistic regression, classification trees, random forests and support vector machines. We sought to validate recently published models meant to predict sentinel node status. Methods We queried our comprehensive, prospectively-collected melanoma database for consecutive melanoma patients undergoing SLNB. Prediction values were estimated based upon 4 published models, calculating the same reported metrics: negative predictive value (NPV), rate of negative predictions (RNP), and false negative rate (FNR). Results Logistic regression performed comparably with our data when considering NPV (89.4% vs. 93.6%); however the model’s specificity was not high enough to significantly reduce the rate of biopsies (SLN reduction rate of 2.9%). When applied to our data, the classification tree produced NPV and reduction in biopsies rates that were lower 87.7% vs. 94.1% and 29.8% vs. 14.3%, respectively. Two published models could not be applied to our data due to model complexity and the use of proprietary software. Conclusions Published models meant to reduce the SLNB rate among patients with melanoma either underperformed when applied to our larger dataset, or could not be validated. Differences in selection criteria and histopathologic interpretation likely resulted in underperformance. Development of statistical predictive models must be created in a clinically applicable manner to allow for both validation and ultimately clinical utility. PMID:21822550
Lu, Wen; He, Lang Chong; Wang, Chang He; Li, Yan Hua; Zhang, San Qi
2008-10-01
Taspine solid lipid nanoparticles (Ta-SLN) and taspine solid lipid nanoparticles modified by galactoside (Ta-G2SLN) were prepared by the film evaporation-extrusion method. The nanoparticles were spherical or near-spherical particles with smooth surface, small size and high encapsulation efficiency. Ta-G2SLN and Ta-SLN showed significant inhibition on 7721 cell growth. Intravenous injection of either Ta-SLN or Ta-G2SLN resulted in a higher plasma and liver concentration and a longer retention time in mice compared with the administration of Ta. These results suggested that SLN tended to be preferentially delivered to the liver and Ta-G2SLN may further enhance liver targeting.
Xie, Shuyu; Zhu, Luyan; Dong, Zhao; Wang, Xiaofang; Wang, Yan; Li, Xihe; Zhou, WenZhong
2011-04-01
Enrofloxacin-loaded solid lipid nanoparticles (SLN) were prepared using fatty acids (tetradecanoic acid, palmitic acid, stearic acid) as lipid matrix by hot homogenization and ultrasonication method. The effect of fatty acids on the characteristics and pharmacokinetics of the SLN were investigated. The results showed that the encapsulation efficiency and loading capacity of nanoparticles varied with fatty acids in the order of stearic acid>palmitic acid>tetradecanoic acid. Furthermore, stearic acid-SLN had larger particle size, bigger polydispersity index (PDI) and higher zeta potential compared with the other two fatty acid formulated SLN. The SLN showed sustained releases in vitro and the released enrofloxacin had the same antibacterial activity as that of the native enrofloxacin. Although in vitro release exhibited similar patterns, within 24 h the releasing rates of the three formulations were significantly different (tetradecanoic acid-SLN>palmitic acid-SLN>stearic acid-SLN). Pharmacokinetic study after a single dose of intramuscular administration to mice demonstrated that tetradecanoic acid-SLN, palmitic acid-SLN, and stearic acid-SLN increased the bioavailability by 6.79, 3.56 and 2.39 folds, and extended the mean residence time (MRT) of the drug from 10.60 h to 180.36, 46.26 and 19.09 h, respectively. These results suggest that the enrofloxacin-fatty acid SLN are promising formulations for sustained release while fatty acids had significant influences on the characteristics and performances of the SLN. Copyright © 2010 Elsevier B.V. All rights reserved.
Madureira, Ana Raquel; Campos, Débora A; Oliveira, Ana; Sarmento, Bruno; Pintado, Maria Manuela; Gomes, Ana Maria
2016-03-01
The evaluation of the digestion effects on bioactive solid lipid nanoparticles (SLN) was performed. For this purpose, witepsol and carnauba SLN loaded with rosmarinic acid (RA) were exposed to the simulated gastrointestinal tract (GIT) conditions prevailing in stomach and small intestine. The simulation of intestinal epithelium was made with a dialysis bag and intestinal cell culture lines. Changes on SLN physical properties, RA release and absorption profiles were followed at each step. Combination of digestion pH and enzymes showed a significant effect upon SLN physical properties. Zeta potential values increased at stomach conditions and decreased at small intestine simulation. Also, at intestine, SLN increased their sizes and released 40-60% of RA, maintaining its initial antioxidant activity values. Sustained release of 40% of RA from SLN was also observed in dialysis tube. At CaCo-2 cell line, both types of SLN showed similar absorbed RA % (ca. 30%). Nevertheless, in CaCo-2/HT29x mix cell lines, for carnauba SLN a lower adsorption RA % was observed than for witepsol SLN. Solid lipid nanoparticles protected RA bioactivity (in terms of antioxidant activity) until reaching the intestine. A controlled release of RA from SLN was achieved and a significant absorption was observed at intestinal cells. Overall, SLN produced with witepsol showed a higher stability than carnauba SLN. Copyright © 2015 Elsevier B.V. All rights reserved.
Bhalekar, Mangesh R; Pokharkar, Varsha; Madgulkar, Ashwini; Patil, Nilam; Patil, Nilkanth
2009-01-01
The purpose of this study was to prepare miconazole nitrate (MN) loaded solid lipid nanoparticles (MN-SLN) effective for topical delivery of miconazole nitrate. Compritol 888 ATO as lipid, propylene glycol (PG) to increase drug solubility in lipid, tween 80, and glyceryl monostearate were used as the surfactants to stabilize SLN dispersion in the SLN preparation using hot homogenization method. SLN dispersions exhibited average size between 244 and 766 nm. All the dispersions had high entrapment efficiency ranging from 80% to 100%. The MN-SLN dispersion which showed good stability for a period of 1 month was selected. This MN-SLN was characterized for particle size, entrapment efficiency, and X-ray diffraction. The penetration of miconazole nitrate from the gel formulated using selected MN-SLN dispersion as into cadaver skins was evaluated ex-vivo using franz diffusion cell. The results of differential scanning calorimetry (DSC) showed that MN was dispersed in SLN in an amorphous state. The MN-SLN formulations could significantly increase the accumulative uptake of MN in skin over the marketed gel and showed a significantly enhanced skin targeting effect. These results indicate that the studied MN-SLN formulation with skin targeting may be a promising carrier for topical delivery of miconazole nitrate.
Song, Hui; Wei, Man; Zhang, Nan; Li, He; Tan, Xiaochuan; Zhang, Yujia; Zheng, Wensheng
2018-01-01
The incidence of central nervous system disease has increased in recent years. However, the transportation of drug is restricted by the blood-brain barrier, contributing to the poor therapeutic effect in the brain. Therefore, the development of a new brain-targeting drug delivery system has become the hotspot of pharmacy. Borneol, a simple bicyclic monoterpene extracted from Dryobalanops aromatica , can direct drugs to the upper body parts according to the theory of traditional Chinese medicine. Dioleoyl phosphoethanolamine (DOPE) was chemically modified by borneol as one of the lipid materials of solid lipid nanoparticle (SLN) in the present study. The borneol-modified chemically solid lipid nanoparticle (BO-SLN/CM), borneol-modified physically solid lipid nanoparticle (BO-SLN/PM), and SLN have similar diameter (of about 87 nm) and morphological characteristics. However, BO-SLN/CM has a lower cytotoxicity, higher cell uptake, and better blood-brain barrier permeability compared with BO-SLN/PM and SLN. BO-SLN/CM has a remarkable targeting function to the brain, while BO-SLN/ PM and SLNs are concentrated at the lung. The present study provides an excellent drug delivery carrier, BO-SLN/CM, having the application potential of targeting to the brain and permeating to the blood-brain barrier.
Mahmood, Muhammad N; Lee, Min W; Linden, Michael D; Nathanson, S D; Hornyak, Thomas J; Zarbo, Richard J
2002-12-01
Numerous immunohistochemical stains have been employed to detect metastatic melanoma in sentinel lymph node (SLN) biopsies. HMB-45 is considered by some as a specific tool to detect early metastatic melanoma (1). Occasionally, one or two isolated HMB-45-positive cells may cause complications in diagnostic interpretation. The goal of this study was to evaluate the reliability of HMB-45 staining of SLNs with sparse isolated positive cells and to compare its staining with anti-Melan A antibody. HMB-45 and anti-Melan A antibody immunostaining was performed on (Group A) 15 histologically negative SLNs excised from patients with malignant melanoma (MM) and on (Group B) 15 histologically negative SLNs excised from patients with breast carcinoma (BC). None of the patients had clinical evidence of systemic metastasis at the time of SLN biopsy. Five cutaneous biopsies with changes of postinflammatory hyperpigmentation (PIHP) were also stained with both antibodies. HMB-45 staining was repeated in all Group B SLNs after blocking endogenous biotins. Electron-microscopic studies were performed on all cases of PIHP. Isolated HMB-45-stained cells were present in 6 of 15 SLNs removed for MM; 8 of 15 for BC; and 3 of 5 cutaneous biopsies of PIHP. HMB-45 reactivity persisted after blocking endogenous biotins in 6 of 8 positive SLNs from Group B. Anti-Melan A antibody was negative in all SLNs of group A and B and in dermal melanophages of all five cases of PIHP. HMB-45 positivity was demonstrated in histologically negative SLNs and cutaneous biopsies, especially in the milieu of aggregated melanophages. Phagocytosis of premelanosomes by macrophages in the draining lymph nodes may account for isolated cell positivity and can hinder correct diagnostic interpretation. HMB-45 may not be a reliable marker for the detection of micro-metastasis of MM and requires correlation with other immunohistochemical markers, such as anti-Melan A antibody, to enhance specificity.
Nuclear medicine imaging of locally advanced laryngeal and hypopharyngeal cancer
NASA Astrophysics Data System (ADS)
Medvedeva, A.; Chernov, V.; Zeltchan, R.; Sinilkin, I.; Bragina, O.; Chijevskaya, S.; Choynzonov, E.; Goldberg, A.
2017-09-01
The diagnostic capabilities of nuclear medicine imaging in the detection and assessment of the spread of laryngeal/hypopharyngeal cancer were studied. A total of 40 patients with histologically verified laryngeal and hypopharyngeal cancer and 20 patients with benign laryngeal lesions were included into the study. Submucosal injections of 99mTc-MIBI and 99mTc-Alotech were made around the tumor. Single photon emission computed tomography (SPECT) was performed 20 minutes after the injection of 99mTc-MIBI. Sentinel lymph nodes (SLNs) were detected in 26 patients. In 18 hours after the injection of 99mTc-Alotech, SPECT was performed. In 24 hours after the injection of 99mTc-Alotech, intraoperative SLN detection was performed using Gamma Finder II. SPECT with 99mTc-MIBI revealed laryngeal and hypopharyngeal tumors in 38 of the 40 patients. The 99mTc-MIBI uptake in metastatic lymph nodes was visualized in 2 (17%) of the 12 patients. Twenty eight SLNs were detected by SPECT and 31 SLNs were identified using the intraoperative gamma probe. The percentage of 99mTc-Alotech in the SLN was 5-10% of the radioactivity in the injection site by SPECT and 18-33% by intraoperative gamma probe detection. Thus, SPECT with 99mTc-MIBI is an effective tool for the diagnosis of laryngeal/hypopharyngeal cancer. The sensitivity, specificity and accuracy of this technique were 95%, 80% and 92%, respectively. The use of 99mTc-Alotech for the detection of SLNs in patients with laryngeal/hypopharyngeal cancer is characterized by 92.8% sensitivity.
Ruktanonchai, Uracha; Sakulkhu, Usawadee; Bejrapha, Piyawan; Opanasopit, Praneet; Bunyapraphatsara, Nuntavan; Junyaprasert, Varaporn; Puttipipatkhachorn, Satit
2009-11-01
In the present study gamma-oryzanol, an antioxidant, was incorporated into three different types of solid lipid: wax, triglycerides, a mixture of glycerides as solid lipid nanoparticles (SLN) and liquid lipid (Miglyol 812) as nanoemulsion (NE). Instability was found only from NE due to its significant increase in particle size and decreased entrapment efficiency (%EE) at a storage temperature of 45 degrees C. Solid lipid type in SLN plays an important role only on %EE, but not chemical stability. A decrease in crystallinity of SLN was observed with the incorporation of gamma-oryzanol and low recrystallization index were found with two glycerides-based SLN. The in vitro release studies demonstrated that a biphasic release pattern fitted well with the Higuchi model of SLN formulations. In comparison, nearly constant release was observed in NE comprised of similar composition. Wax-based SLN demonstrated the lowest cytotoxicity. NE, wax-based SLN and a mixture of glycerides-based SLN were considered to enhance the antioxidant activity of gamma-oryzanol.
NASA Astrophysics Data System (ADS)
Asnawi, Syalwati; Aziz, Azila A.; Aziz, Ramlan A.
2009-06-01
A new delivery system for insect repellent is proposed by the incorporation of geranium oil into solid lipid nanoparticle (SLN). A variety of solvents which act as co-surfactants, were introduced to increase the particle size of GE-SLN. Ethanol, which has a high boiling point and a long chain alcohol produced larger particle than dichloromethane. The structure of SLN was not stable when methanol and acetone were used as co-solvents. Concentration of solvents can also influence the size of SLN. In vitro release experiments showed that SLN was able to reduce the rapid evaporation of geranium oil.
Solid lipid nanodispersions containing mixed lipid core and a polar heterolipid: characterization.
Attama, A A; Schicke, B C; Paepenmüller, T; Müller-Goymann, C C
2007-08-01
This paper describes the characterization of solid lipid nanodispersions (SLN) prepared with a 1:1 mixture of theobroma oil and goat fat as the main lipid matrix and Phospholipon 90G (P90G) as a stabilizer heterolipid, using polysorbate 80 as the mobile surfactant, with a view to applying the SLN in drug delivery. The 1:1 lipid mixture and P90G constituting the lipid matrix was first homogeneously prepared by fusion. Thereafter, the SLN were formulated with a gradient of polysorbate 80 and constant lipid matrix concentration by melt-high pressure homogenisation. The SLN were characterized by time-resolved particle size analysis, zeta potential and osmotic pressure measurements, differential scanning calorimetry (DSC) and wide angle X-ray diffraction (WAXD). Transmission electron microscopy (TEM) and isothermal heat conduction microcalorimetry (IMC) which monitors the in situ crystallization were also carried out on the SLN containing P90G and 1.0 % w/w of polysorbate 80. The results obtained in these studies were compared with SLN prepared with theobroma oil with and without phospholipid. Particle size analysis of SLN indicated reduction in size with increase in concentration of mobile surfactant and was in the lower nanometer range after 3 months except SLN prepared without P90G or polysorbate 80. The lipid nanoparticles had negative potentials after 3 months. WAXD and DSC studies revealed low crystalline SLN after 3 months of storage except in WAXD of SLN formulated with 1.0 % w/w polysorbate 80. TEM micrograph of the SLN containing 1.0 % w/w polysorbate 80 revealed discrete particles whose sizes were in consonance with the static light scattering measurement. In situ crystallization studies in IMC revealed delayed crystallization of the SLN with 1.0 % w/w polysorbate 80. Results indicate lipid mixtures produced SLN with lower crystallinity and higher particle sizes compared with SLN prepared with theobroma oil alone with or without P90G, and would lead to higher drug incorporation efficiency when used in formulation of actives. Mixtures of theobroma oil and goat fat would be suitable for the preparation of nanostructured lipid carriers. SLN of theobroma oil containing phospholipid could prove to be a good ocular or parenteral drug delivery system considering the low particle size, particle size stability and in vivo tolerability of the component lipids. SLN prepared with lipid admixture, which had higher increase in d(90%) on storage are suitable for preparation of topical and transdermal products.
Liu, Fangzhou; Zhu, Yan; Qian, Yichuan; Zhang, Jia; Zhang, Yu; Zhang, Yuan
2017-01-01
To compare the accuracy and feasibility of methylene blue and nano-carbon in clinical tracing of sentinel lymph nodes (SLNs) in patients with papillary thyroid cancer (PTC). Ninety-six PTC patients were selected and randomly divided into a methylene blue group and a nano-carbon group (n=48). During surgery, tracer agent was injected around the tumor, and SLNs were resected and subjected to frozen pathological examination. The results were compared with those of routine pathological examination after surgery. Latent lymph node metastasis (level VI and lateral neck) was detected in both groups, with neck distribution of SLNs. There was no significant difference in the detection rate or accuracy of SLNs between two groups (P>0.05). The incorrect resection rate of parathyroid gland and incidence of temporary hypoparathyroidism in the methylene blue group were significantly higher than those of the nano-carbon group (t=4.137, P<0.05). The state of PTC lymph nodes can be well evaluated by SLN biopsy using both methylene blue and nano-carbon as tracers, but using nano-carbon has a lower incidence rate of parathyroid injury, with great clinical prospects accordingly.
Bañuelos Andrío, Luis; Rodríguez Caravaca, Gil; Argüelles Pintos, Miguel; Mitjavilla Casanova, Mercedes
2014-01-01
To analyze the rate of axillary recurrences (AR) in patients with early breast cancer who had not undergone an axillary node dissection (ALND) because of a negative sentinel lymph node biopsy (SLNB). The study includes 173 patients operated on for breast cancer and selective node biopsy. In 32 patients the SLNB was positive and undergone subsequent ALND. We followed up 141 patients with negative SLNB without LDN, with a median follow up of 55 months (range 74-36). The detection rate of SLN was of 99.42%. After a median follow-up of 4.5 years, there were no axillary recurrences. Two patients developed local recurrence, other two patients developed distant metastases and four patients developed a metachronous tumor. Four patients died, none of them because of breast cancer. The results obtained support the SLNB as an accurate technique in the axillary stratification of patients with breast cancer, offering in the cases of negative SLNB a safe axillary control after 4.5 year follow-up. Copyright © 2013 Elsevier España, S.L.U. and SEMNIM. All rights reserved.
Shah, Kumar A; Joshi, Medha D; Patravale, Vandana B
2009-08-01
The objective of the present investigation was to fabricate glyceryl monostearate SLN by employing a biocompatible microemulsion as a template. Biocompatible excipients such as Tween 20 (as a surfactant) and Transcutol P (a cosourfactant) (at different K(m) ratios) were selected for the fabrication of microemulsions. Pseudo-ternary phase diagrams were plotted to identify the area of the microemulsion existence. Glyceryl monostearate SLN were fabricated by dispersing the microemulsion (maintained at 65 degrees C) into cold water (maintained at 2-3 degrees C). The particle size of the SLN was determined by photon correlation spectroscopy. Tretinoin, a lipophilic anti-acne agent was incorporated into SLN as a model drug. The encapsulation efficiency of tretinoin in the SLN was determined by using Nanosep ultrafilteration device at different lipid loads viz. 1%, 1.5% and 2%. Glyceryl monostearate SLN fabricated from biocompatible microemulsion template exhibited average particle size of 175 nm and polydispersity index of 0.833. Tretinoin could be successfully incorporated into SLN and the encapsulation efficiency ranged from 37-48% at different lipid loads.
Baek, Jong-Suep; Cho, Cheong-Weon
2017-08-01
Curcumin has been reported to exhibit potent anticancer effects. However, poor solubility, bioavailability and stability of curcumin limit its in vivo efficacy for the cancer treatment. Solid lipid nanoparticles (SLN) are a promising delivery system for the enhancement of bioavailability of hydrophobic drugs. However, burst release of drug from SLN in acidic environment limits its usage as oral delivery system. Hence, we prepared N-carboxymethyl chitosan (NCC) coated curcumin-loaded SLN (NCC-SLN) to inhibit the rapid release of curcumin in acidic environment and enhance the bioavailability. The NCC-SLN exhibited suppressed burst release in simulated gastric fluid while sustained release was observed in simulated intestinal fluid. Furthermore, NCC-SLN exhibited increased cytotoxicity and cellular uptake on MCF-7 cells. The lymphatic uptake and oral bioavailability of NCC-SLN were found to be 6.3-fold and 9.5-fold higher than that of curcumin solution, respectively. These results suggest that NCC-SLN could be an efficient oral delivery system for curcumin. Copyright © 2017 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Unal, Bulent; Gur, Akif Serhat; Beriwal, Sushil
2009-11-15
Purpose: Katz suggested a nomogram for predicting having four or more positive nodes in sentinel lymph node (SLN)-positive breast cancer patients. The findings from this formula might influence adjuvant radiotherapy decisions. Our goal was to validate the accuracy of the Katz nomogram. Methods and Materials: We reviewed the records of 309 patients with breast cancer who had undergone completion axillary lymph node dissection. The factors associated with the likelihood of having four or more positive axillary nodes were evaluated in patients with one to three positive SLNs. The nomogram developed by Katz was applied to our data set. The areamore » under the curve of the corresponding receiver operating characteristics curve was calculated for the nomogram. Results: Of the 309 patients, 80 (25.9%) had four or more positive axillary lymph nodes. On multivariate analysis, the number of positive SLNs (p < .0001), overall metastasis size (p = .019), primary tumor size (p = .0001), and extracapsular extension (p = .01) were significant factors predicting for four or more positive nodes. For patients with <5% probability, 90.3% had fewer than four positive nodes and 9.7% had four or more positive nodes. The negative predictive value was 91.7%, and sensitivity was 80%. The nomogram was accurate and discriminating (area under the curve, .801). Conclusion: The probability of four or more involved nodes is significantly greater in patients who have an increased number of positive SLNs, increased overall metastasis size, increased tumor size, and extracapsular extension. The Katz nomogram was validated in our patients. This nomogram will be helpful to clinicians making adjuvant treatment recommendations to their patients.« less
Dianzani, Chiara; Cavalli, Roberta; Zara, Gian Paolo; Gallicchio, Margherita; Lombardi, Grazia; Gasco, Maria Rosa; Panzanelli, Patrizia; Fantozzi, Roberto
2006-01-01
Adhesion of polymorphonuclear cells (PMNs) to vascular endothelial cells (EC) is a critical step in recruitment and infiltration of leukocytes into tissues during inflammation. High doses of butyric acid have been shown to ameliorate inflammation in inflammatory bowel diseases (IBD). Cholesteryl-butyrate solid lipid nanoparticles (chol-but SLN) as prodrug are a possible delivery system for butyric acid. Sodium butyrate or chol-but SLN were coincubated with human PMNs and human umbilical vein EC (HUVEC); adhesion was quantified by computerized microimaging fluorescence analysis. Both chol-but SLN and sodium butyrate displayed antiadhesive effects on FMLP- and IL-1β-stimulated cells in a concentration–response curve (10−8–10−5 M), but chol-but SLN were in all cases more active. Moreover, chol-but SLN inhibited FMLP-induced adhesion of PMNs to FCS-coated plastic wells, thus showing a direct effect on PMNs, while sodium butyrate had little effect. Confocal microscopy showed that fluorescent SLN entered PMNs and HUVEC after 10 min incubation. Chol-but SLN acted either on activated PMN or HUVEC. Chol-but SLN inhibited O2−· production and myeloperoxidase release by PMNs evoked by FMLP, in a dose-dependent, but not time-dependent, manner and were more active than sodium butyrate. In conclusion, in all tests chol-but SLN were more active than sodium butyrate. Thus, chol-but SLN might be a valid alternative to sodium butyrate in the anti-inflammatory therapy of ulcerative colitis, avoiding complications related to the administration of sodium butyrate. PMID:16702992
Doktorovova, Slavomira; Souto, Eliana B; Silva, Amélia M
2018-01-01
Curcumin, a phenolic compound from turmeric rhizome (Curcuma longa), has many interesting pharmacological effects, but shows very low aqueous solubility. Consequently, several drug delivery systems based on polymeric and lipid raw materials have been proposed to increase its bioavailability. Solid lipid nanoparticles (SLN), consisting of solid lipid matrix and a surfactant layer can load poorly water-soluble drugs, such as curcumin, deliver them at defined rates and enhance their intracellular uptake. In the present work, we demonstrate that, despite the drug's affinity to lipids frequently used in SLN production, the curcumin amount loaded in most SLN formulations may be too low to exhibit anticancer properties. The predictive curcumin solubility in solid lipids has been thoroughly analyzed by Hansen solubility parameters, in parallel with the lipid-screening solubility tests for a range of selected lipids. We identified the most suitable lipid materials for curcumin-loaded SLN, producing physicochemically stable particles with high encapsulation efficiency (>90%). Loading capacity of curcumin in SLN allowed preventing the cellular damage caused by cationic SLN on MCF-7 and BT-474 cells but was not sufficient to exhibit drug's anticancer properties. But curcumin-loaded SLN exhibited antioxidant properties, substantiating the conclusions that curcumin's effect in cancer cells is highly dose dependent.
Soddu, Elena; Rassu, Giovanna; Cossu, Massimo; Giunchedi, Paolo; Cerri, Guido; Gavini, Elisabetta
2016-01-01
Cocoa butter (CB) is a largely used excipient in pharmaceutical field. Aim of this work was to set formulative parameters for the preparation of SLN based on "green" lipid matrix for drug delivery as natural, both human and environmental safe systems. Double emulsion technique (w1/o/w2) was selected for SLN preparation. The effect on the dimensional properties of different surfactants (Tween 80 and PEG 40 monostearate) and co-surfactants (PEG400 monostearate, Emulium® Kappa2 and Plurol®Stearique) at different concentrations was evaluated. Stability tests were performed. SLN dispersions were exsiccated and the effect of the dried process on SLN size was evaluated. The influence of temperature on SLN dimensions was investigated at 37 °C. MTT test was performed on raw materials and formulations. The w1/o/w2 is suitable, rapid and economic technique for the preparation of CB SLN. Tween 80-Plurol Stearique combination gives the best results: particles size less than 400 nm and PI of about 0.4 are obtained when PS 2% is used. Both raw materials and formulations are safe. The importance to evaluate the effect of different surfactant and/or co-surfactant on the dimensional properties of SLN is evident by selecting substances with preferable safety profiles, and favorable environmental properties to develop stable "green" SLN.
A constraint optimization based virtual network mapping method
NASA Astrophysics Data System (ADS)
Li, Xiaoling; Guo, Changguo; Wang, Huaimin; Li, Zhendong; Yang, Zhiwen
2013-03-01
Virtual network mapping problem, maps different virtual networks onto the substrate network is an extremely challenging work. This paper proposes a constraint optimization based mapping method for solving virtual network mapping problem. This method divides the problem into two phases, node mapping phase and link mapping phase, which are all NP-hard problems. Node mapping algorithm and link mapping algorithm are proposed for solving node mapping phase and link mapping phase, respectively. Node mapping algorithm adopts the thinking of greedy algorithm, mainly considers two factors, available resources which are supplied by the nodes and distance between the nodes. Link mapping algorithm is based on the result of node mapping phase, adopts the thinking of distributed constraint optimization method, which can guarantee to obtain the optimal mapping with the minimum network cost. Finally, simulation experiments are used to validate the method, and results show that the method performs very well.
Song, Zhangyong; Shen, Ling; Yin, Youping; Tan, Wenyong; Shao, Changwen; Xu, Jinmin; Wang, Zhongkang
2015-03-01
Microsclerotia (MS) formation was successfully induced in Nomuraea rileyi in liquid amended medium (AM) culture. To investigate how N. rileyi senses growth stress and regulates MS differentiation, based on transcriptome library, sho1 and sln1 genes were cloned. The transcription levels of sho1 and sln1 were upregulated in response to the changing culture conditions. To determine the functions of sho1 and sln1, gene-silencing mutants (sholi, sln1i and shol&sln1i) were generated using RNA silencing technology. The significant phenotypic changes in the mutants included reduced conidial yields by 22.72, 40.27, and 63.67 % and virulence by 24.53, 25.74, and 59.04 %, respectively. Furthermore, the mutants presented decreased MS yields by approximately 96 % under changing culture conditions. Our results confirmed the crucial role of Sho1p and Sln1p in sensing growth stress due to changing culture conditions and regulating MS differentiation.
Solid lipid nanoparticles loading adefovir dipivoxil for antiviral therapy
Zhang, Xing-guo; Miao, Jing; Li, Min-wei; Jiang, Sai-ping; Hu, Fu-qiang; Du, Yong-zhong
2008-01-01
Herein, solid lipid nanoparticles (SLN) were proposed as a new drug delivery system for adefovir dipivoxil (ADV). The octadecylamine-fluorescein isothiocynate (ODA-FITC) was synthesized and used as a fluorescence maker to be incorporated into SLN to investigate the time-dependent cellular uptake of SLN by HepG2.2.15. The SLN of monostearin with ODA-FITC or ADV were prepared by solvent diffusion method in an aqueous system. About 15 wt% drug entrapment efficiency (EE) and 3 wt% drug loading (DL) could be reached in SLN loading ADV. Comparing with free ADV, the inhibitory effects of ADV loaded in SLN on hepatitis B surface antigen (HBsAg), hepatitis B e antigen (HBeAg) and hepatitis B virus (HBV) DNA levels in vitro were significantly enhanced. PMID:18543406
In vivo and ex vivo sentinel node mapping does not identify the same lymph nodes in colon cancer.
Andersen, Helene Schou; Bennedsen, Astrid Louise Bjørn; Burgdorf, Stefan Kobbelgaard; Eriksen, Jens Ravn; Eiholm, Susanne; Toxværd, Anders; Riis, Lene Buhl; Rosenberg, Jacob; Gögenur, Ismail
2017-07-01
Identification of lymph nodes and pathological analysis is crucial for the correct staging of colon cancer. Lymph nodes that drain directly from the tumor area are called "sentinel nodes" and are believed to be the first place for metastasis. The purpose of this study was to perform sentinel node mapping in vivo with indocyanine green and ex vivo with methylene blue in order to evaluate if the sentinel lymph nodes can be identified by both techniques. Patients with colon cancer UICC stage I-III were included from two institutions in Denmark from February 2015 to January 2016. In vivo sentinel node mapping with indocyanine green during laparoscopy and ex vivo sentinel node mapping with methylene blue were performed in all patients. Twenty-nine patients were included. The in vivo sentinel node mapping was successful in 19 cases, and ex vivo sentinel node mapping was successful in 13 cases. In seven cases, no sentinel nodes were identified. A total of 51 sentinel nodes were identified, only one of these where identified by both techniques (2.0%). In vivo sentinel node mapping identified 32 sentinel nodes, while 20 sentinel nodes were identified by ex vivo sentinel node mapping. Lymph node metastases were found in 10 patients, and only two had metastases in a sentinel node. Placing a deposit in relation to the tumor by indocyanine green in vivo or of methylene blue ex vivo could only identify sentinel lymph nodes in a small group of patients.
Patil, Hemlata; Feng, Xin; Ye, Xingyou; Majumdar, Soumyajit; Repka, Michael A
2015-01-01
This contribution describes a continuous process for the production of solid lipid nanoparticles (SLN) as drug-carrier systems via hot-melt extrusion (HME). Presently, HME technology has not been used for the manufacturing of SLN. Generally, SLN are prepared as a batch process, which is time consuming and may result in variability of end-product quality attributes. In this study, using Quality by Design (QbD) principles, we were able to achieve continuous production of SLN by combining two processes: HME technology for melt-emulsification and high-pressure homogenization (HPH) for size reduction. Fenofibrate (FBT), a poorly water-soluble model drug, was incorporated into SLN using HME-HPH methods. The developed novel platform demonstrated better process control and size reduction compared to the conventional process of hot homogenization (batch process). Varying the process parameters enabled the production of SLN below 200 nm. The dissolution profile of the FBT SLN prepared by the novel HME-HPH method was faster than that of the crude FBT and a micronized marketed FBT formulation. At the end of a 5-h in vitro dissolution study, a SLN formulation released 92-93% of drug, whereas drug release was approximately 65 and 45% for the marketed micronized formulation and crude drug, respectively. Also, pharmacokinetic study results demonstrated a statistical increase in Cmax, Tmax, and AUC0-24 h in the rate of drug absorption from SLN formulations as compared to the crude drug and marketed micronized formulation. In summary, the present study demonstrated the potential use of hot-melt extrusion technology for continuous and large-scale production of SLN.
Sguizzato, Maddalena; Cortesi, Rita; Gallerani, Eleonora; Drechsler, Markus; Marvelli, Lorenza; Mariani, Paolo; Carducci, Federica; Gavioli, Riccardo; Esposito, Elisabetta; Bergamini, Paola
2017-05-01
The use of solid lipid nanoparticles (SLN) is a promising route for the delivery of platinum complexes aimed to anticancer activity. This paper describes the production and characterization of SLN suitable for the loading of Pt complexes containing the biocompatible phosphine 1,3,5-triaza-7-phosphaadamantane (PTA) as neutral ligand. After a screening of several lipidic phases, stearic acid-based SLN were identified as the most appropriate for the purpose. They were produced by emulsion-dilution method and then characterized in terms of dimension, polydispersity, time stability, pH balance and morphological aspect. Stearic acid SLN are designed as a system able to coordinate to platinum, acting as anionic carboxylic ligands, replacing the base carbonate of the Pt synthon [PtCO 3 (DMSO) 2 ], where also DMSO can subsequently be substituted by phosphinic ligands, namely PTA. SLN functionalised with Pt-PTA were produced and characterized by this synthetic route. The toxicity of plain SLN and the antiproliferative effect of SLN functionalised with Pt-PTA were evaluated on two human cancer cell lines K562 and A2780. The results indicate that SLN can be exploited as a delivery system for Pt complexes with potential anticancer activity. Copyright © 2016 Elsevier B.V. All rights reserved.
Oliveira, Mariana Silva; Lima, Bruno Henrique Santiago; Goulart, Gisele Assis Castro; Mussi, Samuel Vidal; Borges, Gabriel Silva Marques; Oréfice, Rodrigo Lambert; Ferreira, Lucas Antônio Miranda
2018-08-01
This work aims to develop, characterize, and evaluate the anticancer activity of solid lipid nanoparticles (SLN) containing doxorubicin (DOX), an antitumoral from the antracycline class, and sclareol (SC), a lipophilic labdene diterpene (SLN-DOX-SC). The SLN were characterized by Differential Scanning Calorimetry (DSC), X-ray Diffraction (XRD), Small Angle X-ray Diffraction (SAXS), in vitro release, transmission electron microscopy, and polarized light microscopy. Evaluation of cell viability was performed in two cell cultures: MCF-7 (human breast cancer) and 4T1 (murine breast cancer). The SLN showed a size in the range of 128 nm, negative zeta potential, DOX encapsulation efficiency (EE) of 99%, and drug loading (DL) of 66 mg/g. Characterization of the formulation by DSC, XRD, and SAXS revealed the presence of DOX inside the nanoparticles of SLN and suggested increased expulsion/release of this drug when associated with SC. The release profiles revealed that the SLN-DOX-SC showed controlled release of DOX at pH 7.4 with enhanced drug release at low pH, useful for cancer treatment. The SLN-DOX-SC demonstrated to be more effective than the free DOX against 4T1 cells. So, the developed SLN efficiently encapsulate DOX and SC and show good potential as an alternative for cancer treatment.
Van Dijk, Rick; Boers, Eveline; Christoffels, Ingrid; Hermans, Daan
2011-01-01
The quality of interpretations produced by sign language interpreters was investigated. Twenty-five experienced interpreters were instructed to interpret narratives from (a) spoken Dutch to Sign Language of The Netherlands (SLN), (b) spoken Dutch to Sign Supported Dutch (SSD), and (c) SLN to spoken Dutch. The quality of the interpreted narratives was assessed by 5 certified sign language interpreters who did not participate in the study. Two measures were used to assess interpreting quality: the propositional accuracy of the interpreters' interpretations and a subjective quality measure. The results showed that the interpreted narratives in the SLN-to-Dutch interpreting direction were of lower quality (on both measures) than the interpreted narratives in the Dutch-to-SLN and Dutch-to-SSD directions. Furthermore, interpreters who had begun acquiring SLN when they entered the interpreter training program performed as well in all 3 interpreting directions as interpreters who had acquired SLN from birth.
Üner, Melike; Yener, Gülgün
2007-01-01
Solid lipid nanoparticles (SLN) have been reported to be an alternative system to emulsions, liposomes, microparticles and their polymeric counterparts for various application routes since the early 1990s due to their advantages. Various research groups have also increasingly focused on improving their stability in body fluids after administration by coating of particles with hydrophilic molecules such as poly(ethylene)glycol (PEG) derivatives. Altering surface characteristics by coating SLN with hydrophilic molecules improves plasma stability and biodistribution, and subsequent bioavailability of drugs entrapped. Their storage stability is also increased. This paper basicly reviews types of SLN, principles of drug loading and models of drug incorporation. The influence of PEG coating on particle size and surface characteristics is discussed followed by alteration in pharmacokinetics and bioavailability of drugs in order to target the site of action via SLN. The future direction of research and clinical implications of SLN is also considered. PMID:18019829
Indocyanine green detects sentinel lymph nodes in early breast cancer.
Liu, Jun; Huang, Linping; Wang, Ning; Chen, Ping
2017-04-01
Objective To explore the clinical value of indocyanine green (ICG) for the fluorescence-guided detection of sentinel lymph nodes (SLNs) during sentinel lymph node biopsy (SLNB) in patients with early breast cancer. Methods This retrospective study included female patients with breast cancer. Patients were administered methylene blue and ICG using standard techniques. All SLNs that were collected during surgery were submitted for pathological examination. SLNs were defined as those that were either fluorescent, blue, fluorescent and blue or palpably suspicious. Surgical complications, axillary recurrence, distant metastasis and overall survival rates were observed postoperatively. Results A total of 60 patients were enrolled in the study. The fluorescence detection rate of SLNs was 100% ( n = 177), with a mean of 2.95 SLNs per patient. The methylene blue staining rate was 88.3% ( n = 106), with a mean of 1.77 SLNs per patient. Pathological assessment of intraoperative frozen specimens revealed SLN metastases in 10 patients, who immediately underwent axillary lymph node dissection. No patient had axillary recurrence or distant metastases, with a survival rate of 100%. Patients who underwent SLNB showed good appearance in the axillary wound, with no limited shoulder joint abduction and upper limb oedema. Conclusion Fluorescence-guided SLNB has several advantages and is suitable for clinical application.
Sentinel lymph node biopsy in atypical Spitz nevi: is it useful?
Caracò, C; Mozzillo, N; Di Monta, G; Botti, G; Anniciello, A M; Marone, U; Di Cecilia, M L; Staibano, S; De Rosa, G
2012-10-01
The aim of this study was to evaluate the incidence of lymph node metastases in patients with atypical Spitz nevi (ASN) after sentinel lymph node biopsy (SLNB) and during follow-up, and to assess the diagnostic value of the surgical procedure. At the National Cancer Institute of Naples, Italy, 40 patients with ASN underwent SLNB between 2003 and 2011. Medical records were reviewed and all slides of the primary tumours were retrieved, rendered separately, and assessed by four experienced dermatopathologists from two different academic institutions. Each member of the review panel assessed slides separately without recourse to medical notes and blinded to each others' diagnosis. All patients were treated with wide local excision and SLN biopsy according to the standard procedure. All cases were followed up to assess outcomes. The original diagnosis of ASN was confirmed in all 40 cases. No sentinel node positivity was recorded, and no patients developed nodal involvement during a median follow-up of 46 months (range 16-103). All patients were alive and without evidence of locoregional or distant relapse at time of review. In our experience, ASN were not associated with metastatic potential. Surgical staging procedures are not justified and careful clinical surveillance is adequate. Published by Elsevier Ltd.
Oral insulin delivery by means of solid lipid nanoparticles
Sarmento, Bruno; Martins, Susana; Ferreira, Domingos; Souto, Eliana B
2007-01-01
The aim of this work was to produce and characterize cetyl palmitate-based solid lipid nanoparticles (SLN) containing insulin, and to evaluate the potential of these colloidal carriers for oral administration. SLN were prepared by a modified solvent emulsification-evaporation method based on a w/o/w double emulsion. The particle size, zeta potential and association efficiency of unloaded and insulin-loaded SLN were determined and were found to be around 350 nm, negatively charged and the insulin association efficiency was over 43%. After oral administration of insulin-loaded SLN to diabetic rats, a considerable hypoglycemic effect was observed during 24 hours. These results demonstrated that SLN promote the oral absorption of insulin. PMID:18203440
Suzuki, Taku; Yoshihara, Midori; Sakai, Shogo; Tsuji, Kojun; Nagoya, Kouta; Magara, Jin; Tsujimura, Takanori; Inoue, Makoto
2018-05-03
This study aimed to investigate whether the jaw-opening (JOR) and jaw-closing reflexes (JCR) are modulated during not only peripherally, but also centrally, evoked swallowing. Experiments were carried out on 24 adult male Japanese white rabbits. JORs were evoked by trigeminal stimulation at 1 Hz for 30 sec. In the middle 10 sec, either the superior laryngeal nerve (SLN) or cortical swallowing area (Cx) was simultaneously stimulated to evoke swallowing. The peak-to-peak JOR amplitude was reduced during the middle and late 10-sec periods (i.e., during and after SLN or Cx stimulation), and the reduction was dependent on the current intensity of SLN/Cx stimulation: greater SLN/Cx stimulus current resulted in greater JOR inhibition. The reduction rate was significantly greater during Cx stimulation than during SLN stimulation. The amplitude returned to baseline 2 min after 10-sec SLN/Cx stimulation. The effect of co-stimulation of SLN and Cx was significantly greater than that of SLN stimulation alone. There were no significant differences in any parameters of the JCR between conditions. These results clearly showed that JOR responses were significantly suppressed, not only during peripherally evoked swallowing but also during centrally evoked swallowing, and that the inhibitory effect is likely to be larger during centrally compared with peripherally evoked swallowing. The functional implications of these results are discussed. Copyright © 2018. Published by Elsevier B.V.
Chitosan-solid lipid nanoparticles as carriers for topical delivery of tretinoin.
Ridolfi, Daniela M; Marcato, Priscyla D; Justo, Giselle Z; Cordi, Lívia; Machado, Daisy; Durán, Nelson
2012-05-01
Tretinoin (TRE) or all-trans retinoic acid is employed in the topical treatment of various skin diseases including acne and psoriasis. However, its use is strongly limited by side effects and high chemical instability. TRE encapsulation in nanostructured systems reduces these problems. Chitosan is a biopolymer that exhibits a number of interesting properties such as bioadhesion and antibacterial activity. The aim of this work was to prepare and characterize solid lipid nanoparticles (SLN) containing TRE, with and without addition of chitosan, to assess their in vitro cytotoxicity in keratinocytes and to evaluate their antibacterial activity against bacteria related to acne. SLN without (SLN-TRE) and with (SLN-chitosan-TRE) chitosan were prepared by hot high pressure homogenization. The hydrodynamic mean diameter and zeta potential were 162.7±1.4 nm and -31.9±2.0 mV for SLN-TRE, and 284.8±15.0 nm and 55.9±3.1 mV for SLN-chitosan-TRE. The SLN-chitosan-TRE exhibited high encapsulation efficiency, high physical stability in the tested period (one year), were not cytotoxic to keratinocytes and showed high antibacterial activity against P. acnes and S. aureus. Therefore chitosan-SLN can be good candidates to encapsulate TRE and to increase its therapeutic efficacy in the topical treatment of acne. Copyright © 2011 Elsevier B.V. All rights reserved.
Wang, X F; Zhang, S L; Zhu, L Y; Xie, S Y; Dong, Z; Wang, Y; Zhou, W Z
2012-01-01
This study aimed to enhance the antibacterial activity of tilmicosin by solid lipid nanoparticles (SLN). Tilmicosin-loaded hydrogenated castor oil (HCO)-SLN was prepared using a hot homogenisation and ultrasonication method. The physicochemical characteristics of SLN were investigated by scanning electron microscopy (SEM) and photon correlation spectroscopy (PCS). The antibacterial activity of tilmicosin-SLN against Staphylococcus aureus was evaluated by growth inhibition and colony-counting method. A therapeutic study of tilmicosin-SLN was conducted by subcutaneous injection in a mouse mastitis model infected with S. aureus by teat canal infusion. Therapeutic efficacy was assessed by physical appearance of the mammary gland and measurement of colony-forming units (CFU) per gland. The results showed that the diameter, polydispersivity index, zeta potential, encapsulation efficiency and loading capacity of the nanoparticles were 343±26 nm, 0.33±0.08, -7.9±0.4 mV, 60.4±3.3% and 11.2±0.47%, respectively. Tilmicosin-SLN showed a sustained-release effect and sustained and enhanced antibacterial activity in vitro. SLN significantly enhanced the therapeutic efficacy of tilmicosin determined by lower CFU counts and a decreased degree of inflammation. These results demonstrated that the HCO-SLN is an effective carrier to enhance the antibacterial activity of tilmicosin. Copyright © 2010. Published by Elsevier Ltd.
NASA Astrophysics Data System (ADS)
Barbosa, R. M.; da Silva, C. M. G.; Bella, T. S.; de Araújo, D. R.; Marcato, P. D.; Durán, N.; de Paula, E.
2013-04-01
Dibucaine (DBC) is powerful long-lasting local anesthetic, but it is also considered fairly toxic to the CNS. Solid lipid nanoparticles (SLN) and nanostructured lipid carriers (NLC) have attracted attention as carriers for drug delivery. The aim of this study was to develop and to evaluate the cytotoxic activity of DBC-loaded SLN and NLC against 3T3 fibroblast and HaCat keratinocyte cells. The SLN and NLC had myristyl myristate and Liponate®GC as their lipid matrices, respectively, plus a surfactant. SLN and NLC were characterized in terms in their diameter, size distribution, surface charge and DBC encapsulation efficiency. The particle size of SLN and NLC were around 234.33 and 166.62 nm, respectively. The polydispersity index was kept below 0.2 for both nanomaterials. Negative surface charges were observed for both nanoparticles, which decreased in the presence of the anesthetic. Encapsulation efficiency reached 76% and 90%, respectively, in SLN and NLC. DBC alone was found to be toxic to 3T3 and HaCat cells in culture. However, NLC and SLN loaded DBC decreased its intrinsic cytotoxic effect against 3T3 and HaCat cells. In conclusion, encapsulation of DBC in SLN and NLC decreased the in vitro toxicity of the local anesthetic, indicating the potential of these nanocarriers for clinical applications.
Rompicharla, Sri Vishnu Kiran; Bhatt, Himanshu; Shah, Aashma; Komanduri, Neeraja; Vijayasarathy, Dhanya; Ghosh, Balaram; Biswas, Swati
2017-11-01
The aim of the present research was to develop a novel, biocompatible, amenable to industrial scale up and affordable solid lipid nanoparticles (SLN) preparation of curcumin and evaluate the therapeutic efficacy in vitro using cancer cells. We have incorporated cholesterol as the lipid to prepare SLN along with the Poloxamer-188 as stabilizer. High shear homogenization was used to prepare the SLN and formulation was optimized using Quality by Design The optimized Chol CUR SLN exhibited a narrow size distribution with a particle size of 166.4±3.5nm. Percentage encapsulation (%EE) was found to be 76.9±1.9%. The SLN were further characterized by DSC, FTIR, XRD and drug release. In vitro cell studies in MDA-MB-231 (Human Breast cancer) cell line revealed that the Chol CUR SLN showed superior cytotoxicity and uptake in comparison to the free curcumin. Furthermore, Chol CUR SLN induced a significantly higher apoptosis compared to free CUR treatment. These results indicated that the curcumin encapsulated in Chol SLN was able to significantly improve the cytotoxic potential and induction of apoptosis in MDA-MB-231 cells. The promising result from our study could lead a further exploration of this nanoparticle formulation to be utilized clinically for cancer treatment. Copyright © 2017 Elsevier B.V. All rights reserved.
Buparvaquone loaded solid lipid nanoparticles for targeted delivery in theleriosis
Soni, Maheshkumar P.; Shelkar, Nilakash; Gaikwad, Rajiv V.; Vanage, Geeta R.; Samad, Abdul; Devarajan, Padma V.
2014-01-01
Background: Buparvaquone (BPQ), a hydroxynaphthoquinone derivative, has been investigated for the treatment of many infections and is recommended as the gold standard for the treatment of theileriosis. Theileriosis, an intramacrophage infection is localized mainly in reticuloendotheileial system (RES) organs. The present study investigates development of solid lipid nanoparticles (SLN) of BPQ for targeted delivery to the RES. Materials and Methods: BPQ SLN was prepared using melt method by adding a molten mixture into aqueous Lutrol F68 solution (80°C). Larger batches were prepared up to 6 g of BPQ with GMS: BPQ, 2:1. SLN of designed size were obtained using ultraturrax and high pressure homogenizer. A freeze and thaw study was used to optimize type and concentration of cryoprotectant with Sf: Mean particle size, Si: Initial particle size <1.3. Differential scanning calorimetry (DSC), powder X-ray diffraction (XRD) and scanning electron microscope (SEM) study was performed on optimized formulation. Formulation was investigated for in vitro serum stability, hemolysis and cell uptake study. Pharmacokinetic and biodistribution study was performed in Holtzman rat. Results: Based on solubility in lipid; glyceryl monostearate (GMS) was selected for preparation of BPQ SLN. Batches of BPQ SLN were optimized for average particle size and entrapment efficiency at <100 mg solid content. A combination of Solutol HS-15 and Lutrol F68 at 2% w/v and greater enabled the desired Sf/Si < 1.3. Differential scanning calorimetry and powder X-ray diffraction revealed decrease in crystallinity of BPQ in BPQ SLN while, scanning electron microscope revealed spherical morphology. BPQ SLN revealed good stability at 4°C and 25°C. Low hemolytic potential (<8%) and in vitro serum stability up to 5 h was observed. Cytotoxicity of SLN to the U937 cell was low. The macrophage cell line revealed high (52%) uptake of BPQ SLN in 1 h suggesting the potential to RES uptake. SLN revealed longer circulation and biodistrbution study confirmed high RES uptake (75%) in RES organs like liver lung spleen etc. Conclusion: The high RES uptake suggests BPQ SLN as a promising approach for targeted and improved delivery in theileriosis. PMID:24459400
Shuhendler, Adam J; Prasad, Preethy; Leung, Michael; Rauth, Andrew M; Dacosta, Ralph S; Wu, Xiao Yu
2012-09-01
The overexpression of α(v) β(3) integrin receptors on tumor cells and tumor vascular endothelium makes it a useful target for imaging, chemotherapy and anti-angiogenic therapy. However integrin-targeted delivery of therapeutics by nanoparticles have provided only marginal, if any, enhancement of therapeutic effect. This work was thus focused on the development of novel α(v) β(3) -targeted near infrared light-emitting solid lipid nanoparticles (SLN) through conjugation to the α(v) β(3) integrin-specific ligand cyclic Arg-Gly-Asp (cRGD), and the assessment of the effects of α(v) β(3) targeting on nanoparticle biodistribution. Since our previously developed non-targeted "stealth" SLN showed little hepatic accumulation, unlike most reported liposomes and micelles, they served as a reference for quantifying the effects of cRGD-conjugation on tumor uptake and whole animal biodistribution of SLN. Non-targeted SLN, actively targeted (RGD-SLN) and blocked RGD-SLN were prepared to contain near infrared quantum dots for live animal imaging. They were injected intravenously to nude mice bearing xenograft orthotopic human breast tumors or dorsal window chamber breast tumors. Tumor micropharmacokinetics of various SLN formulations were determined using intravital microscopy, and whole animal biodistribution was followed over time by optical imaging. The active tumor targeting with cRGD was found to be a "double-edged sword": while the specificity of RGD-SLN accumulation in tumor blood vessels and their tumor residence time increased, their distribution in the liver, spleen, and kidneys was significantly greater than the non-targeted SLN, leaving a smaller amount of nanoparticles in the tumor tissue. Nevertheless the enhanced specificity and retention of RGD-SLN in tumor neovasculature could make this novel formulation useful for tumor neovascular-specific therapies and imaging applications. Copyright © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Zhu, L; Xie, S; Dong, Z; Wang, X; Wang, Y; Zhou, W
2011-09-01
Poly(lactic-co-glycolic acid) (PLGA) was used as a polymeric emulsifier to encapsulate plasmid DNA into hydrogenated castor oil (HCO)-solid lipid nanoparticles (SLN) by w/o/w double emulsion and solvent evaporation techniques. The effects of PLGA on the preparation, characteristics and transfection efficiency of DNA-loaded SLN were studied. The results showed that PLGA was essential to form the primary w/o emulsion and the stability of the emulsion was enhanced with the increase of PLGA content. DNA-loaded SLN were spherical with smooth surfaces. The SLN had a negative charge in weak acid and alkaline environment but acquired a positive charge in acidic pH and the cationisation capacity of the SLN increased with the increase of PLGA/HCO ratio. Agarose gel electrophoresis demonstrated that the majority of the DNA maintained its structural integrity after preparation and being extracted or released from DNA-loaded SLN. When PLGA/HCO ratio increased from 5 to 15%, the encapsulation efficiency, loading capacity and transfection efficiency of the nanoparticles increased significantly, whereas the changes of particle size and polydispersity index were insignificant. Cytotoxicity study in cell culture demonstrated that the SLN was not toxic.
NASA Astrophysics Data System (ADS)
Cynthia Jemima Swarnavalli, G.; Dinakaran, S.; Divya, S.
2016-10-01
Nanocomposites consisting of silver and solid lipid nanoparticles (SLN) elicit interest for their synergistic effect based enhanced properties in skin hydration. The nanocomposite preparation aims at combining the antimicrobial activity of silver with skin hydration performance of SLN. The nanocomposites designated Ag/SAN (silver/stearic acid nanoparticles), Ag/PAN (silver/palmitic acid nanoparticles) were prepared by incorporating silver nanoparticles into the dispersion of SLN and sonicating for 10 min followed by heating for 1 h at 50 °C in a thermostat. The occlusive property of the two nanocomposites was evaluated in comparison with the pure SLN by adopting de Vringer-de Ronde in vitro occlusion test. The incorporation of silver nanoparticles has improved occlusion factor by 10 % in the case of both composites at SLN concentration of 0.14 mmol. Characterization studies include XRD, DSC, HRSEM, DLS and zeta potential measurement. High resolution scanning electron microscopy (HRSEM) images divulge that the nanoparticles of composite (Ag/SAN) shows halo effect where the hydrophobic stearic acid is oriented at the core and is surrounded by silver nanoparticles while Ag/PAN shows cashew shaped SLN dispersed in silver nanoparticles matrix.
Pandey, Sonia; Patel, Payal; Gupta, Arti
2018-05-21
In the present investigation a factorial design approach attempt was applied to develop the solid lipid nanoparticles (SLN) of Glibenclamide (GLB) a poorly water-soluble drug (BCS -II) used in the treatment of type 2 diabetes. Prime objectives of this experiment are to optimize the SLN formulation of Glibenclamide and improve the therapeutic effectiveness of the developed formulation. Glibenclamide loaded SLNs (GLB-SLN) were fabricated by High speed homogenization technique. A 32-factorial design approach has been employed to assess the influence of two independent variables, namely amount of Poloxamer 188 and Glyceryl Monostearate on entrapment efficiency (% EE) (Y1), Particle Size (nm) (Y2), % drug release at 8hr Q8 (Y3) and 24 hr Q24 (Y4) of prepared SLNs. Differential scanning calorimetry analysis revealed the compatibility of the drug into lipid matrix with surfactant, while Transmission electron and Scanning electron microscopy studies indicated the size and shape of SLN. The entrapment efficiency, particle size, Q8 and Q24 of the optimized SLNs were 88.93%, 125 nm, 31.12±0.951% and 86.07±1.291% respectively. Optimized GLB-SLN formula was derived from an overlay plot. Three dimensional response surface plots and regression equations confirmed the corresponding influence of selected independent variables on measured responses. In vivo testing of the GLB-SLN in diabetic albino rats demonstrated significant antidiabetic effect of GLB-SLN. The hypoglycemic effect obtained by GLB-SLN remained significantly higher than that given by drug alone and marketed formulation, further confirming the higher therapeutic effectiveness of the GLB-SLN formulation. Our findings suggested the feasibility of investigated system for oral administration of Glibenclamide. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.
Priano, Lorenzo; Zara, Gian Paolo; El-Assawy, Nadia; Cattaldo, Stefania; Muntoni, Elisabetta; Milano, Eva; Serpe, Loredana; Musicanti, Claudia; Pérot, Chantal; Gasco, Maria Rosa; Miscio, Giacinta; Mauro, Alessandro
2011-09-01
Intrathecal baclofen administration is the reference treatment for spasticity of spinal or cerebral origin, but the risk of infection or catheter dysfunctions are important limits. To explore the possibility of alternative administration routes, we studied a new preparation comprising solid lipid nanoparticles (SLN) incorporating baclofen (baclofen-SLN). We used SLN because they are able to give a sustained release and to target the CNS. Wistar rats were injected intraperitoneally with baclofen-SLN or baclofen solution (baclofen-sol group) at increasing dosages. At different times up to 4 h, efficacy was tested by the H-reflex and two scales evaluating sedation and motor symptoms due to spinal lesions. Rats were killed and baclofen concentration determined in blood and tissues. Physiological solution or unloaded SLN was used as controls. After baclofen-SLN injection, the effect, consisting in a greater and earlier reduction of the H/M ratio than baclofen-sol group and controls, was statistically significant from a dose of 5 mg/kg and was inversely correlated with dose. Clinical effect of baclofen-SLN on both the behavioral scales was greater than that of baclofen-sol and lasted until 4th hour. Compared with baclofen-sol, baclofen-SLN produced significantly higher drug concentrations in plasma from 2nd hour until 4th hour with a linear decrement and in the brain at all times. In conclusion, our study demonstrated the efficacy of a novel formulation of baclofen, which exploits the advantages of SLN preparations. However, for clinical purposes, high baclofen concentrations in brain tissue and sedation may be unwanted effects, requiring further studies and optimization of dosages. Copyright © 2011 Elsevier B.V. All rights reserved.
Khameneh, Bahman; Halimi, Vahid; Jaafari, Mahmoud Reza; Golmohammadzadeh, Shiva
2015-01-01
Objective(s): In the current study, sunscreen and moisturizing properties of solid lipid nanoparticle (SLN)-safranal formulations were evaluated. Materials and Methods: Series of SLN were prepared using glyceryl monostearate, Tween 80 and different amounts of safranal by high shear homogenization, and ultrasound and high-pressure homogenization (HPH) methods. SLN formulations were characterized for size, zeta potential, morphology, thermal properties, and encapsulation efficacy. The Sun Protection Factor (SPF) of the products was determined in vitro using transpore tape. The moisturizing activity of the products was also evaluated by corneometer. Results: The SPF of SLN-safranal formulations was increased when the amount of safranal increased. Mean particle size for all formulas was approximately 106 nm by probe sonication and 233 nm using HPH method. The encapsulation efficiency of safranal was around 70% for all SLN-safranal formulations. Conclusion: The results conclude that SLN-safranal formulations were found to be effective for topical delivery of safranal and succeeded in providing appropriate sunscreen properties. PMID:25810877
Shah, Brijesh; Khunt, Dignesh; Bhatt, Himanshu; Misra, Manju; Padh, Harish
2015-10-12
In the present investigation, Quality by Design (QbD) approach was applied on the development and optimization of solid lipid nanoparticle (SLN) formulation of hydrophilic drug rivastigmine (RHT). RHT SLN were formulated by homogenization and ultrasonication method using Compritol 888 ATO, tween-80 and poloxamer-188 as lipid, surfactant and stabilizer respectively. The effect of independent variables (X1 - drug: lipid ratio, X2 - surfactant concentration and X3 - homogenization time) on quality attributes of SLN i.e. dependent variables (Y1 - size, Y2 - PDI and Y3 - %entrapment efficiency (%EE)) were investigated using 3(3) factorial design. Multiple linear regression analysis and ANOVA were employed to indentify and estimate the main effect, 2FI, quadratic and cubic effect. Optimized RHT SLN formula was derived from an overlay plot on which further effect of probe sonication was evaluated. Final RHT SLN showed narrow size distribution (PDI- 0.132±0.016) with particle size of 82.5±4.07 nm and %EE of 66.84±2.49. DSC and XRD study showed incorporation of RHT into imperfect crystal lattice of Compritol 888 ATO. In comparison to RHT solution, RHT SLN showed higher in-vitro and ex-vivo diffusion. The diffusion followed Higuchi model indicating drug diffusion from the lipid matrix due to erosion. Histopathology study showed intact nasal mucosa with RHT SLN indicating safety of RHT SLN for intranasal administration. Copyright © 2015 Elsevier B.V. All rights reserved.
Pegi, Ahlin; Julijana, Kristl; Slavko, Pecar; Janez, Strancar; Marjeta, Sentjurc
2003-01-01
Solid lipid nanoparticles (SLN) constitute an attractive drug carrier system. The aim of this study was to investigate the influence of lipophilicity and structure of different model molecules on their distribution in SLN dispersions. SLN composed of glyceryl tripalmitate as lipid and soybean lecithin and poloxamer 188 as stabilizers were prepared by a melt-emulsification process. PC(10,3), MeFASL(10,3), C(14)-Tempo, and Tempol were incorporated into SLN as spin-labeled compounds. The partition of SP between triglyceride and water was determined experimentally by electron paramagnetic resonance (EPR) and compared with calculated partition coefficients. The distribution of molecules in SLN dispersions was determined from the parameters of EPR spectra, from the reduction kinetics of the spin-labeled compounds with sodium ascorbate, and by computer simulation of EPR spectral line shapes. The experimentally obtained partition coefficients increase in the order Tempol < MeFASL(10,3) < C(14)-Tempo, showing the same trend as the partition coefficients calculated according to Rekker. In SLN dispersions, it was estimated that the ratio of SP between solid lipid core, phospholipid layers (deeper in SLN layer or in liposomes and closer to the surface of SLN), and water is for Tempol 0:0:100, for C(14)-Tempo 46:54(20:34):0, for MeFASL(10,3) 34:65(38:27):1, and for PC(10,3) 10:89(26:3:60):1. Copyright 2002 Wiley-Liss, Inc. and the American Pharmaceutical Association
Athwal, Ruvinder Kaur; Clarke, Dayalan; Harries, Simon; Jones, Lucie
2016-01-25
Assessment of the sentinel lymph node biopsy (SLNB) is used to stage the axilla in patients with breast cancer. There are a variety of methods to assess metastatic disease within the SLN. One-step nucleic acid amplification (OSNA) has a high sensitivity for detecting metastatic disease within the SLN and avoids the use of staged axillary surgery. However there remains a paucity of data within the literature on the psychological effects upon patients with the use of OSNA. All patients undergoing breast surgery (breast-conserving surgery or mastectomy) and assessment of the SLNB with OSNA from December 2011 to June 2012 were included in the study. A questionnaire was sent to patient within four weeks of surgery to assess their understanding and satisfaction with the OSNA procedure. 60 patients responded to the questionnaire (83% response rate). All patients were female with a mean age of 63 years (range 38-71 years). 19 patients had positive SLNB as assessed by OSNA and all had ALND. 15 patients expressed pre-operative anxiety about having OSNA although 97% stated that they would be happy to undergo the same procedure again. Our study has identified the anxiety points that patients experience with OSNA based management and this will allow improved direct emotional support and provision of information.
Ponti, Antonio; Mano, Maria Piera; Tomatis, Mariano; Baiocchi, Diego; Barca, Alessandra; Berti, Rosa; Bisanti, Luigi; Casella, Denise; Deandrea, Silvia; Delrio, Daria; Donati, Giovanni; Falcini, Fabio; Frammartino, Brunella; Frigerio, Alfonso; Mantellini, Paola; Naldoni, Carlo; Orzalesi, Lorenzo; Pagano, Giovanni; Pietribiasi, Francesca; Ravaioli, Alessandra; Sedda, Maria Laura; Taffurelli, Mario; Cataliotti, Luigi; Segnan, Nereo
2012-01-01
This survey, conducted by the Italian breast screening network (GISMa), collects yearly individual data on diagnosis and treatment on about 50% of all screen-detected, operated lesions in Italy. The 2010 results show good overall quality and an improving trend over time. Critical issues were identified, including waiting times and compliance with the recommendations on not performing frozen section examination on small lesions. Preoperative diagnosis improved constantly over the years, but there is still a large variation between regions and programmes. For almost 90% of screen-detected invasive cancers the sentinel lymph node technique (SLN) was performed on the axilla, avoiding a large number of potentially harmful dissections. On the other hand, potential overuse of SLN for ductal carcinoma in situ deserves further investigation. The detailed results have been distributed, also by means of a web data warehouse, to regional and local screening programmes in order to allow multidisciplinary discussion and identification of the appropriate solutions to any issues documented by the data. It should be assigned priority to the problem of waiting times. Specialist Breast Units with adequate case volume and enough resources would provide the best setting for making monitoring effective in producing quality improvements with shorter waiting times.
Rowland, Leslie A; Maurya, Santosh K; Bal, Naresh C; Kozak, Leslie; Periasamy, Muthu
2016-07-01
It is well known that uncoupling protein 1 (UCP1) in brown adipose tissue plays an important role in diet-induced thermogenesis. In this study, whether sarcolipin (SLN), a regulator of sarco/endoplasmic reticulum Ca(2+) -ATPase pump in muscle, is also an important player of diet-induced thermogenesis was investigated, as well as whether loss of SLN could be compensated by increased UCP1 expression and vice versa. Age- and sex-matched UCP1(-/-) , SLN(-/-) , and double knockout for both UCP1 and SLN mice maintained in C57Bl/6J background were challenged to high-fat diet for 12 weeks and then analyzed for weight gain, alterations in serum metabolites, and changes in thermogenic protein expression. Loss of either SLN or UCP1 alone was sufficient to cause diet-induced obesity. No compensatory upregulation of UCP1 in SLN(-/-) mice or vice versa was found. Paradoxically, loss of both mechanisms failed to exacerbate the obesity phenotype. Data suggest that both SLN- and UCP1-based adaptive thermogenic mechanisms were essential for achieving maximal diet-induced thermogenesis. When both mechanisms were absent, less efficient thermogenic mechanisms were activated to counter energy imbalance. © 2016 The Obesity Society.
Idebenone-loaded solid lipid nanoparticles for drug delivery to the skin: in vitro evaluation.
Montenegro, Lucia; Sinico, Chiara; Castangia, Ines; Carbone, Claudia; Puglisi, Giovanni
2012-09-15
Idebenone (IDE), a synthetic derivative of ubiquinone, shows a potent antioxidant activity that could be beneficial in the treatment of skin oxidative damages. In this work, the feasibility of targeting IDE into the upper layers of the skin by topical application of IDE-loaded solid lipid nanoparticles (SLN) was evaluated. SLN loading different amounts of IDE were prepared by the phase inversion temperature method using cetyl palmitate as solid lipid and three different non-ionic surfactants: ceteth-20, isoceteth-20 and oleth-20. All IDE loaded SLN showed a mean particle size in the range of 30-49 nm and a single peak in size distribution. In vitro permeation/penetration experiments were performed on pig skin using Franz-type diffusion cells. IDE penetration into the different skin layers depended on the type of SLN used while no IDE permeation occurred from all the SLN under investigation. The highest IDE content was found in the epidermis when SLN contained ceteth-20 or isoceteth-20 as surfactant while IDE distribution into the upper skin layers depended on the amount of IDE loaded when oleth-20 was used as surfactant. These results suggest that the SLN tested could be an interesting carrier for IDE targeting to the upper skin layers. Copyright © 2012 Elsevier B.V. All rights reserved.
Arranja, Alexandra; Gouveia, Luís F; Gener, Petra; Rafael, Diana F; Pereira, Carolina; Schwartz, Simó; Videira, Mafalda A
2016-03-30
In past years, a considerable progress has been made in the conversion of conventional chemotherapy into potent and safe nanomedicines. The ultimate goal is to improve the therapeutic window of current chemotherapeutics by reducing systemic toxicities and to deliver higher concentrations of the chemotherapeutic agents to malignant cells. In this work, we report that PEGylation of the nanocarriers increases drug intracellular bioavailability leading therefore to higher therapeutic efficacy. The surface of the already patented solid lipid nanoparticles (SLN) loaded with paclitaxel (SLN-PTX) was coated with a PEG layer (SLN-PTX_PEG) through an innovative process to provide stable and highly effective nanoparticles complying with the predefined pharmaceutical quality target product profile. We observed that PEGylation not only stabilizes the SLN, but also modulates their cellular uptake kinetics. As a consequence, the intracellular concentration of chemotherapeutics delivered by SLN-PTX_PEG increases. This leads to the increase of efficacy and thus it is expected to significantly circumvent cancer cell resistance and increase patient survival and cure. Copyright © 2016 Elsevier B.V. All rights reserved.
Van Berckelaer, Christophe; Huizing, Manon; Van Goethem, Mireille; Vervaecke, Andrew; Papadimitriou, Konstantinos; Verslegers, Inge; Trinh, Bich X; Van Dam, Peter; Altintas, Sevilay; Van den Wyngaert, Tim; Huyghe, Ivan; Siozopoulou, Vasiliki; Tjalma, Wiebren A A
2016-11-01
To evaluate the role of preoperative axillary staging with ultrasound (US) and fine needle aspiration cytology (FNAC). Can we avoid intraoperative sentinel lymph node (SLN) examination, with an acceptable revision rate by preoperative staging? This study is based on the retrospective data of 336 patients that underwent US evaluation of the axilla as part of their staging. A FNAC biopsy was performed when abnormal lymph nodes were visualized. Patients with normal appearing nodes on US or a benign diagnostic biopsy had removal of the SLNs without intraoperative pathological examination. We calculated the sensitivity, specificity and accuracy of US/FNAC in predicting the necessity of an axillary lymphadenectomy. Subsequently we looked at the total cost and the operating time of 3 models. Model A is our study protocol. Model B is a theoretical protocol based on the findings of the Z0011 trial with only clinical preoperative staging and in Model C preoperative staging and intraoperative pathological examination were both theoretically done. sentinel node, staging, ultrasound, preoperative axillary staging, FNAC, axilla RESULTS: The sensitivity, specificity and accuracy are respectively 0.75 (0.66-0.82), 1.00 (0.99-1.00) and 0.92 (0.88-0.94). Only 26 out of 317 (8.2%) patients that successfully underwent staging needed a revision. The total cost of Model A was 1.58% cheaper than Model C and resulted in a decrease in operation time by 9,46%. The benefits compared with Model B were much smaller. Preoperative US/FNAC staging of the axillary lymph nodes can avoid intraoperative examination of the sentinel node with an acceptable revision rate. It saves tissue, reduces operating time and decreases healthcare costs in general. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Ferrara, Benedetta; Biasibetti, Elena; Schiffer, Davide; Mellai, Marta; Annovazzi, Laura; Cangemi, Luigi; Muntoni, Elisabetta; Dianzani, Umberto
2018-01-01
Aim: To develop an innovative delivery system for temozolomide (TMZ) in solid lipid nanoparticles (SLN), which has been preliminarily investigated for the treatment of melanoma. Materials and Methods: SLN-TMZ was obtained through fatty acid coacervation. Its pharmacological effects were assessed and compared with free TMZ in in vitro and in vivo models of melanoma and glioblastoma. Results: Compared to the standard free TMZ, SLN-TMZ exerted larger effects, when cell proliferation of melanoma cells, and neoangiogeneis were evaluated. SLN-TMZ also inhibited growth and vascularization of B16-F10 melanoma in C57/BL6 mice, without apparent toxic effects. Conclusion: SLN could be a promising strategy for the delivery of TMZ, allowing an increased stability of the drug and thereby its employment in the treatment of aggressive malignacies. PMID:29364157
The role of the superior laryngeal nerve in esophageal reflexes
Medda, B. K.; Jadcherla, S.; Shaker, R.
2012-01-01
The aim of this study was to determine the role of the superior laryngeal nerve (SLN) in the following esophageal reflexes: esophago-upper esophageal sphincter (UES) contractile reflex (EUCR), esophago-lower esophageal sphincter (LES) relaxation reflex (ELIR), secondary peristalsis, pharyngeal swallowing, and belch. Cats (N = 43) were decerebrated and instrumented to record EMG of the cricopharyngeus, thyrohyoideus, geniohyoideus, and cricothyroideus; esophageal pressure; and motility of LES. Reflexes were activated by stimulation of the esophagus via slow balloon or rapid air distension at 1 to 16 cm distal to the UES. Slow balloon distension consistently activated EUCR and ELIR from all areas of the esophagus, but the distal esophagus was more sensitive than the proximal esophagus. Transection of SLN or proximal recurrent laryngeal nerves (RLN) blocked EUCR and ELIR generated from the cervical esophagus. Distal RLN transection blocked EUCR from the distal cervical esophagus. Slow distension of all areas of the esophagus except the most proximal few centimeters activated secondary peristalsis, and SLN transection had no effect on secondary peristalsis. Slow distension of all areas of the esophagus inconsistently activated pharyngeal swallows, and SLN transection blocked generation of pharyngeal swallows from all levels of the esophagus. Slow distension of the esophagus inconsistently activated belching, but rapid air distension consistently activated belching from all areas of the esophagus. SLN transection did not block initiation of belch but blocked one aspect of belch, i.e., inhibition of cricopharyngeus EMG. Vagotomy blocked all aspects of belch generated from all areas of esophagus and blocked all responses of all reflexes not blocked by SLN or RLN transection. In conclusion, the SLN mediates all aspects of the pharyngeal swallow, no portion of the secondary peristalsis, and the EUCR and ELIR generated from the proximal esophagus. Considering that SLN is not a motor nerve for any of these reflexes, the role of the SLN in control of these reflexes is sensory in nature only. PMID:22403790
Sebaceous carcinoma of the vulva: critical approach to grading and review of the literature.
Pusiol, T; Morichetti, D; Zorzi, M G
2011-06-01
Sebaceous glands are abundant on the vulva, but vulvar sebaceous carcinoma (SC) is an uncommon neoplasm. We report a case of SC of the vulva in a 51 year-old woman. The patient presented a 6-month history of an asymptomatic 2.5 x 1.5 cm exophytic tumour localized on the left labium majora. Tumorectomy was performed. Histologically, the lesion had an irregular lobular growth pattern composed of lobules or sheets of malignant cells separated by fibrovascular stroma. There was a mixture of sebaceous-type differentiation, small ducts and areas showing basaloid or squamous features. Centrally-located tumour cells showed moderate EMA immunoreactivity, especially enhancing cytoplasmic "bubbliness". Tumour cells were immunoreactive for CAM 5.2. The immunoreactivity for intranuclear p53 staining was > 10%. Southern blot hybridization and PCR studies did not detect HPV DNA. Hemivulvectomy was performed. After 18 months of follow-up, the patient has no evidence of recurrence, metastases or other malignant tumours. The grading of cutaneous SC proposed by Rutten et al. (World Health Organization Classification of Skin Tumours) and Patterson & Wick (Nonmelanocytic Tumours of the Skin. Armed Forces Institute of Pathology) is based on patterns of tumour growth rather than cytological features. Such grading of skin SC, including vulvar SC, should not be used since its prognostic value has not been sufficiently documented. As the number of reported vulvar SCs is very limited, their natural history is unknown and the optimal treatment has not been established. The follow-up of 7 reported cases supports the general opinion that the tumour may be aggressive. SC groin node metastases carry a devastating prognosis, and unrecognized disease in the inguinofemoral lymph nodes is nearly always fatal. The use of sentinel lymph nodes (SLN) has evolved as an effective surgical technique for identifying early subclinical regional nodal involvement for many solid tumours throughout the body for staging disease; this is because extra-ocular SCs cause widespread metastatic disease. In our opinion, SLN should be used in conjunction with wide local excision of the primary tumour to investigate regional subclinical metastases. In the presence of a positive sentinel node, early lymphadenectomy with or without radiotherapy could be used to reduce tumour-related morbidity and mortality. The histopathologic differential diagnosis of SC is wide-ranging, including virtually all other malignant clear cell tumours of the skin. The proliferative pattern, immunostaining and cytologic features permit exclusion of neoplasms that mimic SC, but a diagnosis of SC should be rendered only if the overall attributes of the lesion are appropriate for such a interpretation.
Hypericin encapsulated in solid lipid nanoparticles: phototoxicity and photodynamic efficiency.
Lima, Adriel M; Pizzol, Carine Dal; Monteiro, Fabíola B F; Creczynski-Pasa, Tânia B; Andrade, Gislaine P; Ribeiro, Anderson O; Perussi, Janice R
2013-08-05
The hydrophobicity of some photosensitizers can induce aggregation in biological systems, which consequently reduces photodynamic activity. The conjugation of photosensitizers with nanocarrier systems can potentially be used to overcome this problem. The objective of this study was to prepare and characterise hypericin-loaded solid lipid nanoparticles (Hy-SLN) for use in photodynamic therapy (PDT). SLN were prepared using the ultrasonication technique, and their physicochemical properties were characterised. The mean particle size was found to be 153 nm, with a low polydispersity index of 0.28. One of the major advantages of the SLN formulation is its high entrapment efficiency (EE%). Hy-SLN showed greater than 80% EE and a drug loading capacity of 5.22% (w/w). To determine the photodynamic efficiency of Hy before and after encapsulation in SLN, the rate constants for the photodecomposition of two (1)O2 trapping reagents, DPBF and AU, were determined. These rate constants exhibited an increase of 60% and 50% for each method, respectively, which is most likely due to an increase in the lifetime of the triplet state caused by the increase in solubility. Hy-SLN presented a 30% increase in cell uptake and a correlated improvement of 26% in cytotoxicity. Thus, all these advantages suggest that Hy-loaded SLN has potential for use in PDT. Copyright © 2013 Elsevier B.V. All rights reserved.
Guri, Anilda; Gülseren, Ibrahim; Corredig, Milena
2013-09-01
Solid lipid nanoparticles (SLN) have shown potential for encapsulation, protection and delivery of lipophilic functional components. In this study, we have investigated the capabilities of SLN to deliver a hydrophobic polyphenol compound, curcumin, in a coculture system of absorptive Caco-2 and mucus secreting HT29-MTX cells. The cells were grown on transport filters to mimic the human intestinal epithelium. Because of the hydrophobic nature of curcumin, its delivery to the basolateral compartment is expected to take place via a paracellular route. The changes in curcumin concentration in various compartments (i.e., apical, basolateral, mucus, and cell lysates) were evaluated using fluorescence spectroscopy. Two SLN systems were prepared with different emulsifying agents. The encapsulation of curcumin in SLN caused enhanced delivery compared to unencapsulated curcumin. In addition, SLN showed enhanced delivery compared to emulsion droplets containing liquid soy oil. The SLN were retained on the apical mucosal layer to a greater extent than emulsion droplets. The presence of SLN did not affect the integrity of the cellular junctions, as indicated by the TEER values, and the route of transport of the solid particles was simple diffusion, with permeability rates of about 7 × 10(-6) cm s(-1). Approximately 1% of total curcumin was delivered to the basolateral compartment, suggesting that most of the curcumin was absorbed and metabolized by the cell.
NASA Astrophysics Data System (ADS)
Wang, Jing-yi; Wang, Yu; Meng, Xia
2016-11-01
In this study, cisplatin (CDDP)-loaded chitosan-coated solid lipid nanoparticles (SLN) was successfully formulated to treat HeLa cervical carcinoma. The formulation nanoparticles were nanosized and exhibited a controlled release of drug in physiological conditions. The blank nanoparticles exhibited an excellent biocompatibility profile indicating its suitability for cancer targeting. The incorporation of CDDP in SLN remarkably increased the cancer cell death as evident from the MTT assay. Importantly, CDDP-loaded chitosan-coated SLN (CChSLN) significantly ( P < 0.05) decreased the viability of cancer cells even at low concentration. The higher cytotoxicity potential of CChSLN was attributed to the higher cellular uptake as well as the sustained drug release manner in comparison with CSLN. Consistent with the cytotoxicity assay, CChSLN showed the lowest IC50 value of 0.6125 μg/ml while CSLN presented 1.156 μg/ml. CChSLN showed a significantly higher apoptosis in cancer cells compared to that of CSLN and CDDP, which is attributed to the better internalization of nanocarriers and controlled release of anticancer drugs in the intracellular environment. Our findings suggest that this new formulation could be a promising alternative for the treatment of cervical cancers. These findings are encouraging us to continue our research, with a more extended investigation of cellular response in real time and in animal models.
Li, Jian-Chun; Zhang, Wen-Jing; Zhu, Jin-Xiu; Zhu, Na; Zhang, Hong-Min; Wang, Xiu; Zhang, Jin; Wang, Qing-Qing
2015-01-01
To investigate the brain delivery in rat by nasal Quetiapine fumarate (QF) loaded with solid lipid nanoparticles in situ gel (QF-SLN-gel). QF-SLN-gel was prepared through micro-emulsion technique. The rat model of schizophrenia was established by intraperitoneal injection of (+)-MK-801, evaluated by stereotypic behavior, Mori’s Water Maze (MWM) test and hematoxylin and eosin (HE) staining of hippocampus. The animals were administrated with QF via oral, nasal or tail vein approach and the concentration of QF in blood and brain was determined using high performance liquid chromatography (HPLC). The QF-SLN-gel was even and transparent, having size of 117.8±2.67 d.nm, potential of 57.2±0.24 mV and EF of 97.6±0.58%. After administration of QF-SLN-gel, the concentration of QF in blood and brain of rats in nasal QF-SLN-gel group was similar with that of rats in tail vein QF group, but significantly higher than that of rats in oral QF group. The hippocampal morphology changes induced by (+)-MK-801 were ameliorated by QF, with advantage of nasal QF-SLN-gel over tail vein QF. The nasal QF-SLN-gel had stable and good brain delivery and could ameliorate the damages in rat model of schizophrenia induced by (+)-MK-801. PMID:26770349
Is the External Branch of the Superior Laryngeal Nerve Dispensable in Thyroid Surgery?
Wahba, Basim; Sasaki, Clarence T.
2016-01-01
Background: There is growing evidence that the external branch of the superior laryngeal nerve (eSLN) participates in thyroarytenoid (TA) contraction, but little data quantify its role in vocal cord adduction. Injury to the eSLN, such as in thyroid surgery, is difficult to diagnose and likely underappreciated. It is the authors' belief that eSLN injury contributes to aspiration by depriving its contribution to the laryngeal plexus. The goal of this study was to measure the glottic closing force (GCF) from eSLN stimulation in a porcine model. Methods: The recurrent laryngeal nerve (RLN) and eSLN were identified bilaterally in four porcine necks. Bilateral RLNs and eSLNs were stimulated simultaneously to obtain a control GCF using a pressure transducer placed in the glottis. Subsequently, bilateral eSLNs were stimulated and the GCF measured to quantify its percent contribution to the control value. Results: Stimulation of the RLNs and the eSLNs each led to TA muscle contraction and a measureable GCF in all four porcine necks. The control GCF was 1000.1 mmHg, while the eSLN mediated CGF was 800 mmHg. The percentage GCF attributable to the eSLN was thus 800/1000 = 80%. Conclusions: Reflex glottic closure is one of the most important mechanisms for the prevention of aspiration during deglutition. The biomechanical quantification of glottic closure can be shown as the GCF. This study has shown that the eSLN contributes in a significant way to the GCF in a porcine model, a finding that has not been quantified to the best of the authors' knowledge. Therefore, greater focus should be placed on preserving this nerve in thyroid surgery. PMID:26528734
Asahi, Michio; Otsu, Kinya; Nakayama, Hiroyuki; Hikoso, Shungo; Takeda, Toshihiro; Gramolini, Anthony O.; Trivieri, Maria G.; Oudit, Gavin Y.; Morita, Takashi; Kusakari, Yoichiro; Hirano, Shuta; Hongo, Kenichi; Hirotani, Shinichi; Yamaguchi, Osamu; Peterson, Alan; Backx, Peter H.; Kurihara, Satoshi; Hori, Masatsugu; MacLennan, David H.
2004-01-01
Sarcolipin (SLN) inhibits the cardiac sarco(endo)plasmic reticulum Ca2+ ATPase (SERCA2a) by direct binding and is superinhibitory if it binds through phospholamban (PLN). To determine whether overexpression of SLN in the heart might impair cardiac function, transgenic (TG) mice were generated with cardiac-specific overexpression of NF-SLN (SLN tagged at its N terminus with the FLAG epitope). The level of NF-SLN expression (the NF-SLN/PLN expression ratio) was equivalent to that which induces profound superinhibition when coexpressed with PLN and SERCA2a in HEK-293 cells. In TG hearts, the apparent affinity of SERCA2a for Ca2+ was decreased compared with non-TG littermate control hearts. Invasive hemodynamic and echocardiographic analyses revealed impaired cardiac contractility and ventricular hypertrophy in TG mice. Basal PLN phosphorylation was reduced. In isolated papillary muscle subjected to isometric tension, peak amplitudes of Ca2+ transients and peak tensions were reduced, whereas decay times of Ca2+ transients and relaxation times of tension were increased in TG mice. Isoproterenol largely restored contractility in papillary muscle and stimulated PLN phosphorylation to wild-type levels in intact hearts. No compensatory changes in expression of SERCA2a, PLN, ryanodine receptor, and calsequestrin were observed in TG hearts. Coimmunoprecipitation indicated that overexpressed NF-SLN was bound to both SERCA2a and PLN, forming a ternary complex. These data suggest that NF-SLN overexpression inhibits SERCA2a through stabilization of SERCA2a–PLN interaction in the absence of PLN phosphorylation and through the inhibition of PLN phosphorylation. Inhibition of SERCA2a impairs contractility and calcium cycling, but responsiveness to β-adrenergic agonists may prevent progression to heart failure. PMID:15201433
Minelli, R; Serpe, L; Pettazzoni, P; Minero, V; Barrera, G; Gigliotti, CL; Mesturini, R; Rosa, AC; Gasco, P; Vivenza, N; Muntoni, E; Fantozzi, R; Dianzani, U; Zara, GP; Dianzani, C
2012-01-01
BACKGROUND AND PURPOSE Cholesteryl butyrate solid lipid nanoparticles (cholbut SLN) provide a delivery system for the anti-cancer drug butyrate. These SLN inhibit the adhesion of polymorphonuclear cells to the endothelium and may act as anti-inflammatory agents. As cancer cell adhesion to endothelium is crucial for metastasis dissemination, here we have evaluated the effect of cholbut SLN on adhesion and migration of cancer cells. EXPERIMENTAL APPROACH Cholbut SLN was incubated with a number of cancer cell lines or human umbilical vein endothelial cells (HUVEC) and adhesion was quantified by a computerized micro-imaging system. Migration was detected by the scratch ‘wound-healing’ assay and the Boyden chamber invasion assay. Expression of ERK and p38 MAPK was analysed by Western blot. Expression of the mRNA for E-cadherin and claudin-1 was measured by RT-PCR. KEY RESULTS Cholbut SLN inhibited HUVEC adhesiveness to cancer cell lines derived from human colon–rectum, breast, prostate cancers and melanoma. The effect was concentration and time-dependent and exerted on both cancer cells and HUVEC. Moreover, these SLN inhibited migration of cancer cells and substantially down-modulated ERK and p38 phosphorylation. The anti-adhesive effect was additive to that induced by the triggering of B7h, which is another stimulus inhibiting both ERK and p38 phosphorylation, and cell adhesiveness. Furthermore, cholbut SLN induced E-cadherin and inhibited claudin-1 expression in HUVEC. CONCLUSION AND IMPLICATIONS These results suggest that cholbut SLN could act as an anti-metastastic agent and they add a new mechanism to the anti-tumour activity of this multifaceted preparation of butyrate. PMID:22049973
Ko, Young Tag; Choi, Dong-Kug
2018-01-01
Solid lipid nanoparticle (SLN) delivery systems have a wide applicability in the delivery of phyto-bioactive compounds to treat various chronic diseases, including diabetes, cancer, obesity and neurodegenerative diseases. The multiple benefits of SLN delivery include improved stability, smaller particle size, leaching prevention and enhanced lymphatic uptake of the bioactive compounds through oral delivery. However, the burst release makes the SLN delivery systems inadequate for the oral delivery of various phyto-bioactive compounds that can treat such chronic diseases. Recently, the surface-modified SLN (SMSLN) was observed to overcome this limitation for oral delivery of phyto-bioactive compounds, and there is growing evidence of an enhanced uptake of curcumin delivered orally via SMSLNs in the brain. This review focuses on different SLN and SMSLN systems that are useful for oral delivery of phyto-bioactive compounds to treat various chronic diseases. PMID:29588585
Stoichiometric Lithium Niobate (SLN) Based Linearized Electro-Optic (EO) Modulator
2006-01-01
AFRL-SN-RS-TR-2006-15 Final Technical Report January 2006 STOICHIOMETRIC LITHIUM NIOBATE (SLN) BASED LINEARIZED ELECTRO - OPTIC (EO...LITHIUM NIOBATE (SLN) BASED LINEARIZED ELECTRO - OPTIC (EO) MODULATOR 6. AUTHOR(S) Dr Stuart Kingsley, Dr Sri Sriram 5. FUNDING NUMBERS C...SUBJECT TERMS electro - optic modulator, linearization, directional coupler, variable coupling, optical waveguide, Mach-Zehnder, photonic link, lithium
Continuous manufacturing of solid lipid nanoparticles by hot melt extrusion.
Patil, Hemlata; Kulkarni, Vijay; Majumdar, Soumyajit; Repka, Michael A
2014-08-25
Solid lipid nanoparticles (SLN) can either be produced by hot homogenization of melted lipids at higher temperatures or by a cold homogenization process. This paper proposes and demonstrates the formulation of SLN for pharmaceutical applications by combining two processes: hot melt extrusion (HME) technology for melt-emulsification and high-pressure homogenization (HPH) for size reduction. This work aimed at developing continuous and scalable processes for SLN by mixing a lipid and aqueous phase containing an emulsifier in the extruder barrel at temperatures above the melting point of the lipid and further reducing the particle size of emulsion by HPH linked to HME in a sequence. The developed novel platform demonstrated better process control and size reduction compared to the conventional process of hot homogenization (batch process). Varying the process parameters enabled the production of SLN below 200 nm (for 60 mg/ml lipid solution at a flow rate of 100ml/min). Among the several process parameters investigated, the lipid concentration, residence time and screw design played major roles in influencing the size of the SLN. This new process demonstrates the potential use of hot melt extrusion technology for continuous and large-scale production of SLN. Copyright © 2014 Elsevier B.V. All rights reserved.
Gallarate, Marina; Trotta, Michele; Battaglia, Luigi; Chirio, Daniela
2009-08-01
A method to produce solid lipid nanoparticles (SLN) from W/O/W multiple emulsions was developed applying the solvent-in-water emulsion-diffusion technique. Insulin was chosen as hydrophilic peptide drug to be dissolved in the acidic inner aqueous phase of multiple emulsions and to be consequently carried in SLN. Several partially water-miscible solvents with low toxicity were screened in order to optimize emulsions and SLN composition, after assessing that insulin did not undergo any chemical modification in the presence of the different solvents and under the production process conditions. SLN of spherical shape and with mean diameters in the 600-1200 nm range were obtained by simple water dilution of the W/O/W emulsion. Best results, in terms of SLN mean diameter and encapsulation efficiencies, were obtained using glyceryl monostearate as lipid matrix, butyl lactate as a solvent, and soy lecithin and Pluronic F68 as surfactants. Encapsulation efficiencies up to 40% of the loaded amount were obtained, owing to the actual multiplicity of the system; the use of multiple emulsion-derived SLN can be considered a useful strategy to encapsulate a hydrophilic drug in a lipid matrix.
Acute toxicity study of tilmicosin-loaded hydrogenated castor oil-solid lipid nanoparticles.
Xie, Shuyu; Wang, Fenghua; Wang, Yan; Zhu, Luyan; Dong, Zhao; Wang, Xiaofang; Li, Xihe; Zhou, Wenzhong
2011-11-20
Our previous studies demonstrated that tilmicosin-loaded hydrogenated castor oil solid lipid nanoparticles (Til-HCO-SLN) are a promising formulation for enhanced pharmacological activity and therapeutic efficacy in veterinary use. The purpose of this work was to evaluate the acute toxicity of Til-HCO-SLN. Two nanoparticle doses were used for the study in ICR mice. The low dose (766 mg/kg.bw) with tilmicosin 7.5 times of the clinic dosage and below the median lethal dose (LD(50)) was subcutaneously administered twice on the first and 7th day. The single high dose (5 g/kg.bw) was the practical upper limit in an acute toxicity study and was administered subcutaneously on the first day. Blank HCO-SLN, native tilmicosin, and saline solution were included as controls. After medication, animals were monitored over 14 days, and then necropsied. Signs of toxicity were evaluated via mortality, symptoms of treatment effect, gross and microscopic pathology, and hematologic and biochemical parameters. After administration of native tilmicosin, all mice died within 2 h in the high dose group, in the low dose group 3 died after the first and 2 died after the second injections. The surviving mice in the tilmicosin low dose group showed hypoactivity, accelerated breath, gloomy spirit and lethargy. In contrast, all mice in Til-HCO-SLN and blank HCO-SLN groups survived at both low and high doses. The high nanoparticle dose induced transient clinical symptoms of treatment effect such as transient reversible action retardation, anorexy and gloomy spirit, increased spleen and liver coefficients and decreased heart coefficients, microscopic pathological changes of liver, spleen and heart, and minor changes in hematologic and biochemical parameters, but no adverse effects were observed in the nanoparticle low dose group. The results revealed that the LD50 of Til-HCO-SLN and blank HCO-SLN exceeded 5 g/kg.bw and thus the nanoparticles are considered low toxic according to the toxicity categories of chemicals. Moreover, HCO-SLN significantly decreased the toxicity of tilmicosin. Normal clinic dosage of Til-HCO-SLN is safe as evaluated by acute toxicity.
Acute toxicity study of tilmicosin-loaded hydrogenated castor oil-solid lipid nanoparticles
2011-01-01
Background Our previous studies demonstrated that tilmicosin-loaded hydrogenated castor oil solid lipid nanoparticles (Til-HCO-SLN) are a promising formulation for enhanced pharmacological activity and therapeutic efficacy in veterinary use. The purpose of this work was to evaluate the acute toxicity of Til-HCO-SLN. Methods Two nanoparticle doses were used for the study in ICR mice. The low dose (766 mg/kg.bw) with tilmicosin 7.5 times of the clinic dosage and below the median lethal dose (LD50) was subcutaneously administered twice on the first and 7th day. The single high dose (5 g/kg.bw) was the practical upper limit in an acute toxicity study and was administered subcutaneously on the first day. Blank HCO-SLN, native tilmicosin, and saline solution were included as controls. After medication, animals were monitored over 14 days, and then necropsied. Signs of toxicity were evaluated via mortality, symptoms of treatment effect, gross and microscopic pathology, and hematologic and biochemical parameters. Results After administration of native tilmicosin, all mice died within 2 h in the high dose group, in the low dose group 3 died after the first and 2 died after the second injections. The surviving mice in the tilmicosin low dose group showed hypoactivity, accelerated breath, gloomy spirit and lethargy. In contrast, all mice in Til-HCO-SLN and blank HCO-SLN groups survived at both low and high doses. The high nanoparticle dose induced transient clinical symptoms of treatment effect such as transient reversible action retardation, anorexy and gloomy spirit, increased spleen and liver coefficients and decreased heart coefficients, microscopic pathological changes of liver, spleen and heart, and minor changes in hematologic and biochemical parameters, but no adverse effects were observed in the nanoparticle low dose group. Conclusions The results revealed that the LD50 of Til-HCO-SLN and blank HCO-SLN exceeded 5 g/kg.bw and thus the nanoparticles are considered low toxic according to the toxicity categories of chemicals. Moreover, HCO-SLN significantly decreased the toxicity of tilmicosin. Normal clinic dosage of Til-HCO-SLN is safe as evaluated by acute toxicity. PMID:22098626
Ponti, Antonio; Mano, Maria Piera; Tomatis, Mariano; Baiocchi, Diego; Barca, Alessandra; Berti, Rosa; Casella, Denise; D'Ambrosio, Enrico; Delos, Erika; Donati, Giovanni; Falcini, Fabio; Frammartino, Brunella; Frigerio, Alfonso; Giudici, Fabiola; Mantellini, Paola; Naldoni, Carlo; Olla Atzeni, Carlo; Orzalesi, Lorenzo; Pagano, Giovanni; Pietribiasi, Francesca; Pitarella, Sabina; Ravaioli, Alessandra; Silvestri, Anna; Taffurelli, Mario; Tidone, Enrica; Zanconati, Fabrizio; Segnan, Nereo
2015-01-01
This annual survey, conducted by the Italian group for mammography screening (GISMa), collects individual data on diagnosis and treatment of about 50% of screen-detected, operated lesions in Italy. The 2011-2012 results show good overall quality and an improving trend over time. A number of critical issues have been identified, including waiting times (which have had a worsening trend over the years) and compliance with the recommendation of not performing frozen section examination on small lesions. Pre-operative diagnosis improved constantly over time, but there is still a large variation between Regions and programmes. For almost 90% of screen-detected invasive cancers a sentinel lymph node (SLN) biopsy was performed on the axilla, avoiding a large number of potentially harmful dissections. On the other hand, potential overuse of SLN dissection for ductal carcinoma in situ, although apparently starting to decline, deserves further investigation. The detailed results have been distributed, among other ways by means of a web-based data-warehouse, to regional and local screening programmes, in order to allow multidisciplinary discussion and identification of the appropriate solutions to any issues documented by the data. The problem of waiting times should be assigned priority. Specialist Breast Units with adequate case volume and enough resources would provide the best setting for making monitoring effective in producing quality improvements with shorter waiting times.
Formulation and evaluation of metoclopramide solid lipid nanoparticles for rectal suppository.
Mohamed, Radwa A; Abass, Haidy A; Attia, Mohamed A; Heikal, Ola A
2013-11-01
The purpose of this study was to formulate and characterize metoclopramide solid lipid nanoparticles (MCP-SLNs) and incorporating it into suppository bases for treatment of nausea and vomiting, produced with chemotherapeutic agents, using one dose per day. MCP-SLNs was prepared using high shear homogenization (hot homogenization) technique using different surfactants (tween 80, poloxamer 407, poloxamer 188 and cremophore) in two different concentrations (2.5% and 5%) then solid lipid nanoparticle (SLN), whose release percentage above 50%, was incorporated into suppository for treatment of nausea and vomiting. The prepared SLN and suppositories were then evaluated and characterized. Formulation of poloxamer 407 with compritol and drug (F9) produced highest in-vitro % release (80%). Transmission electron microscopy showed that SLN had round and spherical shape in form of solid dispersion or drug-enriched core. Particle size analysis of SLN showed a size range of 24.99-396.8 nm. Negative zeta potential proves complete drug entrapment. In-vivo study of MCP-SLN suppositories produced the same %GE as the market metoclopramide (MCP) suppository (Primperan) with sustained release effect. MCP-SLN suppositories (formula F) can reverse decrease in %GE because of emesis with sustained release effect. So it succeeded to be an alternative to MCP suppositories with no multiple dosing. © 2013 Royal Pharmaceutical Society.
Molecular dynamics of water and monovalent-ions transportation mechanisms of pentameric sarcolipin.
Cao, Yipeng; Wu, Xue; Lee, Imshik; Wang, Xinyu
2016-01-01
The Sarcolipin (SLN) is a transmembrane protein that can form a self-assembled pentamer. In this work, the homology modeling and all-atom molecular dynamic (MD) simulation was performed to study the model of SLN pentamer in POPC (1-palmitoyl-2-oleoyl-sn-glycero-3-phosphocholine) membrane. The potential of mean force (PMF) was calculated for transmembrane transportation of Na(+), Cl(-) and water molecule along the pore channel of penta-SLN complex. The root mean square deviation (RMSD) of the SLN pentamer in POPC membrane showed that the stabilized SLN protein complex could exist in the membrane and that the Na(+) and Cl(-) could not permeate through the channel when the pore was under the vacuum state, but the water could permeate through from cytoplasm to lumen. Under the aqueous state, our simulation demonstrated that hydrated state of Na(+) and Cl(-) could pass through the channel. The PMF and radii of the pore showed that the channel had a gate at Leu(21) that is a key hydrophobicity residue in the channel. Our simulations help to clarify and to understand better the SLN pentamer channel that had a hydrophobic gate and could switch Na(+) and Cl(-) ion permeability by hydrated and vacuum states. © 2015 Wiley Periodicals, Inc.
Cross-Disciplinary Analysis of Lymph Node Classification in Lung Cancer on CT Scanning.
El-Sherief, Ahmed H; Lau, Charles T; Obuchowski, Nancy A; Mehta, Atul C; Rice, Thomas W; Blackstone, Eugene H
2017-04-01
Accurate and consistent regional lymph node classification is an important element in the staging and multidisciplinary management of lung cancer. Regional lymph node definition sets-lymph node maps-have been created to standardize regional lymph node classification. In 2009, the International Association for the Study of Lung Cancer (IASLC) introduced a lymph node map to supersede all preexisting lymph node maps. Our aim was to study if and how lung cancer specialists apply the IASLC lymph node map when classifying thoracic lymph nodes encountered on CT scans during lung cancer staging. From April 2013 through July 2013, invitations were distributed to all members of the Fleischner Society, Society of Thoracic Radiology, General Thoracic Surgical Club, and the American Association of Bronchology and Interventional Pulmonology to participate in an anonymous online image-based and text-based 20-question survey regarding lymph node classification for lung cancer staging on CT imaging. Three hundred thirty-seven people responded (approximately 25% participation). Respondents consisted of self-reported thoracic radiologists (n = 158), thoracic surgeons (n = 102), and pulmonologists who perform endobronchial ultrasonography (n = 77). Half of the respondents (50%; 95% CI, 44%-55%) reported using the IASLC lymph node map in daily practice, with no significant differences between subspecialties. A disparity was observed between the IASLC definition sets and their interpretation and application on CT scans, in particular for lymph nodes near the thoracic inlet, anterior to the trachea, anterior to the tracheal bifurcation, near the ligamentum arteriosum, between the bronchus intermedius and esophagus, in the internal mammary space, and adjacent to the heart. Use of older lymph node maps and inconsistencies in interpretation and application of definitions in the IASLC lymph node map may potentially lead to misclassification of stage and suboptimal management of lung cancer in some patients. Published by Elsevier Inc.
Zhou, Zhengyang; Chen, Hongwei; Lipowska, Malgorzata; Wang, Liya; Yu, Qiqi; Yang, Xiaofeng; Tiwari, Diana; Yang, Lily; Mao, Hui
2016-01-01
The ability to reliably detect sentinel lymph nodes for sentinel lymph node biopsy and lymphadenectomy is important in clinical management of patients with metastatic cancers. However, the traditional sentinel lymph node mapping with visible dyes is limited by the penetration depth of light and fast clearance of the dyes. On the other hand, sentinel lymph node mapping with radionucleotide technique has intrinsically low spatial resolution and does not provide anatomic details in the sentinel lymph node mapping procedure. This work reports the development of a dual modality imaging probe with magnetic resonance and near infrared imaging capabilities for sentinel lymph node mapping using magnetic iron oxide nanoparticles (10 nm core size) conjugated with a near infrared molecule with emission at 830 nm. Accumulation of magnetic iron oxide nanoparticles in sentinel lymph nodes leads to strong T2 weighted magnetic resonance imaging contrast that can be potentially used for preoperative localization of sentinel lymph nodes, while conjugated near infrared molecules provide optical imaging tracking of lymph nodes with a high signal to background ratio. The new magnetic nanoparticle based dual imaging probe exhibits a significant longer lymph node retention time. Near infrared signals from nanoparticle conjugated near infrared dyes last up to 60 min in sentinel lymph node compared to that of 25 min for the free near infrared dyes in a mouse model. Furthermore, axillary lymph nodes, in addition to sentinel lymph nodes, can be also visualized with this probe, given its slow clearance and sufficient sensitivity. Therefore, this new dual modality imaging probe with the tissue penetration and sensitive detection of sentinel lymph nodes can be applied for preoperative survey of lymph nodes with magnetic resonance imaging and allows intraoperative sentinel lymph node mapping using near infrared optical devices. PMID:23812946
Pizzol, Carine Dal; Filippin-Monteiro, Fabíola Branco; Restrepo, Jelver Alexander Sierra; Pittella, Frederico; Silva, Adny Henrique; de Souza, Paula Alves; de Campos, Angela Machado; Creczynski-Pasa, Tânia Beatriz
2014-01-01
Nine types of solid lipid nanoparticle (SLN) formulations were produced using tripalmitin (TPM), glyceryl monostearate (GM) or stearic acid (SA), stabilized with lecithin S75 and polysorbate 80. Formulations were prepared presenting PI values within 0.25 to 0.30, and the physicochemical properties, stability upon storage and biocompatibility were evaluated. The average particle size ranged from 116 to 306 nm, with a negative surface charge around −11 mV. SLN presented good stability up to 60 days. The SLN manufactured using SA could not be measured by DLS due to the reflective feature of this formulation. However, TEM images revealed that SA nanoparticles presented square/rod shapes with an approximate size of 100 nm. Regarding biocompatibility aspects, SA nanoparticles showed toxicity in fibroblasts, causing cell death, and produced high hemolytic rates, indicating toxicity to red blood cells. This finding might be related to lipid type, as well as, the shape of the nanoparticles. No morphological alterations and hemolytic effects were observed in cells incubated with SLN containing TPM and GM. The SLN containing TPM and GM showed long-term stability, suggesting good shelf-life. The results indicate high toxicity of SLN prepared with SA, and strongly suggest that the components of the formulation should be analyzed in combination rather than separately to avoid misinterpretation of the results. PMID:25141003
Zhang, Hong; Zhang, Fu-Ming; Yan, Shi-Jun
2012-01-01
Sorafenib solid lipid nanoparticles (S-SLN) were prepared by emulsion evaporation–solidification at low temperature. Morphology was examined by transmission electron microscope. Particle size and zeta potential were determined by laser granularity equipment. Encapsulation efficiency (EE) was detected by Sephadex gel chromatography and high-performance liquid chromatography (HPLC). The in vitro release profile of S-SLN was studied with dialysis technology. The lyophilized injection of S-SLN was prepared by freeze drying and analyzed by differential scanning calorimetry. The plasma concentration of sorafenib in blood was determined by HPLC. The solid lipid nanoparticles assumed a spherical shape with an even distribution of diameter and particle size 108.23 ± 7.01 nm (n = 3). The polydispersity index, zeta potential, and EE were determined to be 0.25 ± 0.02, −16.37 ± 0.65 mV, and 93.49% ± 1.87%, respectively (n = 3). The in vitro release accorded with the Weibull distribution model. An equal volume of 15% (w/v) mannitol performed better as the protective agent for a lyophilized injection of S-SLN with a new material phase formation. The pharmacokinetic processes of sorafenib solution and lyophilized injection of S-SLN in vivo were in accordance with the two-compartment and one-compartment models, respectively. S-SLN nanoparticles are thus considered a promising drug-delivery system. PMID:22787390
Rossi, Emma C; Kowalski, Lynn D; Scalici, Jennifer; Cantrell, Leigh; Schuler, Kevin; Hanna, Rabbie K; Method, Michael; Ade, Melissa; Ivanova, Anastasia; Boggess, John F
2017-03-01
Sentinel-lymph-node mapping has been advocated as an alternative staging technique for endometrial cancer. The aim of this study was to measure the sensitivity and negative predictive value of sentinel-lymph-node mapping compared with the gold standard of complete lymphadenectomy in detecting metastatic disease for endometrial cancer. In the FIRES multicentre, prospective, cohort study patients with clinical stage 1 endometrial cancer of all histologies and grades undergoing robotic staging were eligible for study inclusion. Patients received a standardised cervical injection of indocyanine green and sentinel-lymph-node mapping followed by pelvic lymphadenectomy with or without para-aortic lymphadenectomy. 18 surgeons from ten centres (tertiary academic and community non-academic) in the USA participated in the trial. Negative sentinel lymph nodes (by haematoxylin and eosin staining on sections) were ultra-staged with immunohistochemistry for cytokeratin. The primary endpoint, sensitivity of the sentinel-lymph-node-based detection of metastatic disease, was defined as the proportion of patients with node-positive disease with successful sentinel-lymph-node mapping who had metastatic disease correctly identified in the sentinel lymph node. Patients who had mapping of at least one sentinel lymph node were included in the primary analysis (per protocol). All patients who received study intervention (injection of dye), regardless of mapping result, were included as part of the assessment of mapping and in the safety analysis in an intention-to-treat manner. The trial was registered with ClinicalTrials.gov, number NCT01673022 and is completed and closed. Between Aug 1, 2012, and Oct 20, 2015, 385 patients were enrolled. Sentinel-lymph-node mapping with complete pelvic lymphadenectomy was done in 340 patients and para-aortic lymphadenectomy was done in 196 (58%) of these patients. 293 (86%) patients had successful mapping of at least one sentinel lymph node. 41 (12%) patients had positive nodes, 36 of whom had at least one mapped sentinel lymph node. Nodal metastases were identified in the sentinel lymph nodes of 35 (97%) of these 36 patients, yielding a sensitivity to detect node-positive disease of 97·2% (95% CI 85·0-100), and a negative predictive value of 99·6% (97·9-100). The most common grade 3-4 adverse events or serious adverse events were postoperative neurological disorders (4 patients) and postoperative respiratory distress or failure (4 patients). 22 patients had serious adverse events, with one related to the study intervention: a ureteral injury incurred during sentinel-lymph-node dissection. Sentinel lymph nodes identified with indocyanine green have a high degree of diagnostic accuracy in detecting endometrial cancer metastases and can safely replace lymphadenectomy in the staging of endometrial cancer. Sentinel lymph node biopsy will not identify metastases in 3% of patients with node-positive disease, but has the potential to expose fewer patients to the morbidity of a complete lymphadenectomy. Indiana University Health, Indiana University Health Simon Cancer Center, and the Indiana University Department of Obstetrics and Gynecology. Copyright © 2017 Elsevier Ltd. All rights reserved.
Production of solid lipid nanoparticles (SLN): scaling up feasibilities.
Dingler, A; Gohla, S
2002-01-01
Solid lipid nanoparticles (SLN/Lipopearls) are widely discussed as a new colloidal drug carrier system. In contrast to polymeric systems, such as Polylactic copolyol microcapsules, these systems show with a good biocompatibility, if applied parenterally. The solid lipid matrices can be comprised of fats or waxes, and allow protection of incorporated active ingredients against chemical and physical degradation. The SLN can either be produced by 'hot homogenization' of melted lipids at elevated temperatures or by a 'cold homogenization' process. This paper deals with production technologies for SLN formulations, based on non-ethoxylated fat components for topical application and high pressure homogenization. Based on the chosen fat components, a novel and easy manufacturing and scaling-up method was developed to maintain chemical and physical integrity of the encapsulated active ingredients in the carrier.
Gokce, Evren H; Korkmaz, Emrah; Tuncay-Tanrıverdi, Sakine; Dellera, Eleonora; Sandri, Giuseppina; Bonferoni, M Cristina; Ozer, Ozgen
2012-01-01
Background The effective delivery of coenzyme Q10 (Q10) to the skin has several benefits in therapy for different skin pathologies. However, the delivery of Q10 to deeper layers of skin is challenging due to low aqueous solubility of Q10. Liposomes and solid lipid nanoparticles (SLN) have many advantages to accomplish the requirements in topical drug delivery. This study aims to evaluate the influence of these nanosystems on the effective delivery of Q10 into the skin. Methods Q10-loaded liposomes (LIPO-Q10) and SLNs (SLN-Q10) were prepared by thin film hydration and high shear homogenization methods, respectively. Particle size (PS), polydispersity index (PI), zeta potential (ZP), and drug entrapment efficiency were determined. Differential scanning calorimetry analysis and morphological transmission electron microscopy (TEM) examination were conducted. Biocompatibility/cytotoxicity studies of Q10-loaded nanosystems were performed by means of cell culture (human fibroblasts) under oxidative conditions. The protective effect of formulations against production of reactive oxygen species were comparatively evaluated by cytofluorometry studies. Results PS of uniform SLN-Q10 and LIPO-Q10 were determined as 152.4 ± 7.9 nm and 301.1 ± 8.2 nm, respectively. ZPs were −13.67 ± 1.32 mV and −36.6 ± 0.85 mV in the same order. The drug entrapment efficiency was 15% higher in SLN systems. TEM studies confirmed the colloidal size. SLN-Q10 and LIPO-Q10 showed biocompatibility towards fibroblasts up to 50 μM of Q10, which was determined as suitable for cell proliferation. The mean fluorescence intensity % depending on ROS production determined in cytofluorometric studies could be listed as Q10 ≥ SLN-Q10 > LIPO-Q10. Conclusion The LIPO-Q10 system was able to enhance cell proliferation. On the contrary, SLN-Q10 did not show protective effects against ROS accumulation. As a conclusion, liposomes seem to have advantages over SLN in terms of effective delivery of Q10 to skin for antioxidant purposes. PMID:23055723
Use of Networked Collaborative Concept Mapping To Measure Team Processes and Team Outcomes.
ERIC Educational Resources Information Center
Chung, Gregory K. W. K.; O'Neil, Harold F., Jr.; Herl, Howard E.; Dennis, Robert A.
The feasibility of using a computer-based networked collaborative concept mapping system to measure teamwork skills was studied. A concept map is a node-link-node representation of content, where the nodes represent concepts and links represent relationships between connected concepts. Teamwork processes were examined for a group concept mapping…
ERIC Educational Resources Information Center
Lee, Jae Hwa; Segev, Aviv
2012-01-01
Maps such as concept maps and knowledge maps are often used as learning materials. These maps have nodes and links, nodes as key concepts and links as relationships between key concepts. From a map, the user can recognize the important concepts and the relationships between them. To build concept or knowledge maps, domain experts are needed.…
Lee, Chang Min; Park, Sungsoo; Park, Seong-Heum; Jung, Sung Woo; Choe, Jung Wan; Sul, Ji-Young; Jang, You Jin; Mok, Young-Jae; Kim, Jong-Han
2017-04-01
The aim of this study was to investigate the feasibility of sentinel node mapping using a fluorescent dye and visible light in patients with gastric cancer. Recently, fluorescent imaging technology offers improved visibility with the possibility of better sensitivity or accuracy in sentinel node mapping. Twenty patients with early gastric cancer, for whom laparoscopic distal gastrectomy with standard lymphadenectomy had been planned, were enrolled in this study. Before lymphadenectomy, the patients received a gastrofiberoscopic peritumoral injection of fluorescein solution. The sentinel basin was investigated via laparoscopic fluorescent imaging under blue light (wavelength of 440-490 nm) emitted from an LED curing light. The detection rate and lymph node status were analyzed in the enrolled patients. In addition, short-term clinical outcomes were also investigated. No hypersensitivity to the dye was identified in any enrolled patients. Sentinel nodes were detected in 19 of 20 enrolled patients (95.0%), and metastatic lymph nodes were found in 2 patients. The latter lymph nodes belonged to the sentinel basin of each patient. Meanwhile, 1 patient (5.0%) experienced a postoperative complication that was unrelated to sentinel node mapping. No mortality was recorded among enrolled cases. Sentinel node mapping with visible light fluorescence was a feasible method for visualizing sentinel nodes in patients with early gastric cancer. In addition, this method is advantageous in terms of visualizing the concrete relationship between the sentinel nodes and surrounding structures.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Haffty, Bruce G., E-mail: hafftybg@cinj.rutgers.edu; McCall, Linda M.; Ballman, Karla V.
2016-03-01
Purpose: American College of Surgeons Oncology Group Z1071 was a prospective trial evaluating the false negative rate of sentinel lymph node (SLN) surgery after neoadjuvant chemotherapy (NAC) in breast cancer patients with initial node-positive disease. Radiation therapy (RT) decisions were made at the discretion of treating physicians, providing an opportunity to evaluate variability in practice patterns following NAC. Methods and Materials: Of 756 patients enrolled from July 2009 to June 2011, 685 met all eligibility requirements. Surgical approach, RT, and radiation field design were analyzed based on presenting clinical and pathologic factors. Results: Of 401 node-positive patients, mastectomy was performed inmore » 148 (36.9%), mastectomy with immediate reconstruction in 107 (26.7%), and breast-conserving surgery (BCS) in 146 patients (36.4%). Of the 284 pathologically node-negative patients, mastectomy was performed in 84 (29.6%), mastectomy with immediate reconstruction in 69 (24.3%), and BCS in 131 patients (46.1%). Bilateral mastectomy rates were higher in women undergoing reconstruction than in those without (66.5% vs 32.2%, respectively, P<.0001). Use of internal mammary RT was low (7.8%-11.2%) and did not differ between surgical approaches. Supraclavicular RT rate ranged from 46.6% to 52.2% and did not differ between surgical approaches but was omitted in 193 or 408 node-positive patients (47.3%). Rate of axillary RT was more frequent in patients who remained node-positive (P=.002). However, 22% of patients who converted to node-negative still received axillary RT. Post-mastectomy RT was more frequently omitted after reconstruction than mastectomy (23.9% vs 12.1%, respectively, P=.002) and was omitted in 19 of 107 patients (17.8%) with residual node-positive disease in the reconstruction group. Conclusions: Most clinically node-positive patients treated with NAC undergoing mastectomy receive RT. RT is less common in patients undergoing reconstruction. There is wide variability in RT fields. These practice patterns conflict with expert recommendations and ongoing trial guidelines. There is a significant need for greater uniformity and guidelines regarding RT following NAC.« less
Scaling up feasibility of the production of solid lipid nanoparticles (SLN).
Gohla, S H; Dingler, A
2001-01-01
Solid lipid nanoparticles (SLN/Lipopearls) are widely discussed as colloidal drug carrier system. In contrast to polymeric systems, such as polylactic copolyol capsules, these systems show up with a good biocompatibility, if applied parenterally. The solid lipid matrices can be comprised of fats or waxes and allow protection of incorporated active ingredients against chemical and physical degradation. The SLN can either be produced by "hot homogenisation" of melted lipids at elevated temperatures or a "cold homogenization" process. This paper deals with production technologies for SLN formulations, based on non-ethoxylated fat components for topical application and high pressure homogenization (APV Deutschland GmbH, D-Lübeck). Based on the chosen fat components, a novel and easy manufacturing and scaling up method was developed to maintain chemical and physical integrity of encapsulated active and carrier.
Edible solid lipid nanoparticles (SLN) as carrier system for antioxidants of different lipophilicity
Oehlke, Kathleen; Behsnilian, Diana; Mayer-Miebach, Esther; Weidler, Peter G.; Greiner, Ralf
2017-01-01
Ferulic acid (FA) and tocopherol (Toc) loaded solid lipid nanoparticles (SLN) were prepared by a hot homogenisation method. The particle size distribution, zeta potential and melting behaviour of the SLN as well as the stability, encapsulation efficiency and radical scavenging activity of FA and Toc in the SLN were analysed. The different formulations containing up to 2.8 mg g−1 of FA or Toc were stable during at least 15 weeks of storage at room temperature. Despite partial degradation and / or release of FA and Toc during storage, significant radical scavenging activity was maintained. DSC measurements and radical scavenging tests after different time periods revealed that the re-structuring of the lipid matrix was connected to the enhanced antioxidant activity of Toc but did not affect the activity of FA. PMID:28192494
Distinct Disease and Functional Characteristics of Thyroid Surgery-Related Vocal Fold Palsy.
Tseng, Wen-Chun; Pei, Yu-Cheng; Wong, Alice M K; Li, Hsueh-Yu; Fang, Tuan-Jen
2016-07-01
Iatrogenic trauma induced by thyroid surgery is the most common etiology of unilateral vocal fold paralysis (UVFP). UVFP after thyroid surgery may lead to profound physical and psychosocial distress. This study comprehensively evaluated UVFP caused by thyroid surgery, and compared the results with those caused by other surgical trauma. Patients with surgery-related UVFP were evaluated using quantitative laryngeal electromyography, videolaryngostroboscopy, voice acoustic analysis, the Voice Outcome Survey, and the Short Form-36 Health Survey quality-of-life questionnaire. Patients with thyroid surgery and other surgeries were compared. A total of 105 patients were recruited, of whom 52 and 53 were assigned to the thyroid surgery and the other surgery group, respectively. Patients in the thyroid surgery group had a higher proportion of external branch of superior laryngeal nerve (eSLN) involvement, longer duration from disease onset to the first laryngeal electromyography examination, lower jitter, higher harmonic-to-noise ratio, and better quality of life compared with the other surgery group. Specifically for patients in the thyroid surgery group, those with eSLN involvement tended to have more pronounced impairment in jitter and shimmer compared with patients without eSLN involvement. UVFP caused by thyroid surgery has a distinct clinical presentation with relatively high involvement in the eSLN, better voice acoustics, longer waiting time before asking for evaluation, and less impact on quality of life. The involvement of eSLN in these patients further impaired their voice. Early referral is suggested for these patients, especially with suspected eSLN injury.
Solid lipid nanoparticles for delivery of Calendula officinalis extract.
Arana, Lide; Salado, Clarisa; Vega, Sandra; Aizpurua-Olaizola, Oier; de la Arada, Igor; Suarez, Tatiana; Usobiaga, Aresatz; Arrondo, José Luis R; Alonso, Alicia; Goñi, Félix M; Alkorta, Itziar
2015-11-01
Solid lipid nanoparticles (SLN) composed of long-chain fatty acids (palmitic acid, stearic acid or arachidic acid), Epikuron 200 (purified phosphatidylcholine), and bile salts (cholate, taurocholate or taurodeoxycholate) have been prepared by dilution of a microemulsion. A total of five different systems were prepared, and characterized by photon correlation spectroscopy, transmission electron microscopy, differential scanning calorimetry, and infrared spectroscopy. The SLN formulation showing optimal properties (lowest size and polydispersity index and highest zeta potential) was obtained with stearic acid and taurodeoxycholate as cosurfactant. This formulation was loaded with Calendula officinalis extract, a natural compound used on ophthalmic formulations given its anti-inflammatory, emollient, and wound repairing activity. Calendula-loaded SLN preparations were characterized in order to determine loading capacity and entrapment efficiency. In vitro cytotoxicity and wound healing efficacy of Calendula-loaded SLN compared to that of a free plant extract were evaluated on a conjunctival epithelium cell line WKD. Our results suggest that this SLN formulation is a safe and solvent-free Calendula extract delivery system which could provide a controlled therapeutic alternative for reducing disease-related symptoms and improving epithelium repair in ocular surface. Copyright © 2015 Elsevier B.V. All rights reserved.
Xie, Shuyu; Pan, Baoliang; Wang, Ming; Zhu, Luyan; Wang, Fenghua; Dong, Zhao; Wang, Xiaofang; Zhou, WenZhong
2010-07-01
The purpose of this study was to formulate praziquantel (PZQ)-loaded hydrogenated castor oil (HCO) solid lipid nanoparticles (SLN) to enhance the bioavailability and prolong the systemic circulation of the drug. PZQ was encapsulated into HCO nanoparticles by a hot homogenization and ultrasonication method. The physicochemical characteristics of SLN were investigated by optical microscope, scanning electron microscopy and photon correlation spectroscopy. Pharmacokinetics were studied after oral, subcutaneous and intramuscular administration in mice. The diameter, polydispersivity index, zeta potential, encapsulation efficiency and loading capacity of the nanoparticles were 344.0 +/- 15.1 nm, 0.31 +/- 0.08, -16.7 +/- 0.5 mV, 62.17 +/- 6.53% and 12.43 +/- 1.31%, respectively. In vitro release of PZQ-loaded HCO-SLN exhibited an initial burst release followed by a sustained release. SLN increased the bioavailability of PZQ by 14.9-, 16.1- and 2.6-fold, and extended the mean residence time of the drug from 7.6, 6.6 and 8.2 to 95.9, 151.6 and 48.2 h after oral, subcutaneous and intramuscular administration, respectively. The PZQ-loaded HCO-SLN could be a promising formulation to enhance the pharmacological activity of PZQ.
Synergetic Effect of SLN-Curcumin and LDH-5-Fu on SMMC-7721 Liver Cancer Cell Line
Zhu, Rongrong; Wu, Xianzheng; Xiao, Yu; Gao, Bo; Xie, Qian
2013-01-01
Abstract Curcumin and 5-Fluorouracil (5-Fu) have been reported to have anticancer potentials and show certain synergetic effect on some cancer cell lines. However, the poor bioavailability and rapid metabolism limited their medical application. In this study, we encapsulated curcumin with solid lipid nanoparticles (SLN), 5-Fu with Layered double hydroxides (LDHs) separately and tested its properties and anticancer potentials. SLN-curcumin and LDH-5-Fu were determined to be 100 and 60 nm by Transmission Electron Microscopy detection, and the loading efficiency were 28%±2.5% and 16.7%±1.8%, individually. Furthermore, SLN-curcumin and LDH-5-Fu showed a significantly synergetic effect on SMMC-7721 cell stronger than plain drugs together, of which the Idrug loaded nano-carriers was only 0.315. FACS analysis revealed that the combination of SLN-curcumin and LDH-5-Fu induced 80.1% apoptosis in SMMC-7721 cells, which were 1.7-folds of the sum of the two plain drug loaded carriers. The results demonstrated the significant synergetic anticancer potentials of nano-encapsulated curcumin and 5-Fu, which could be further explored for the treatment of other carcinoma. PMID:23808828
Sentinel-Lymphknoten-Biopsie des Melanoms mittels Indocyaningrün und "FOVIS"-System.
Göppner, Daniela; Nekwasil, Stephan; Jellestad, Anne; Sachse, Alexander; Schönborn, Karl-Heinz; Gollnick, Harald
2017-02-01
Der Nachweis metastatischer Infiltrate im Sentinel-Lymphkoten (SLN) gilt als wesentlicher prognostischer Faktor des Melanoms. Alternativ zur Farbstoffmethode mit Patentblau zum Goldstandard der SLN-Biopsie (SLNB) mittels Radiokolloid wird die fluoreszenzoptische Darstellung mit Hilfe von Indocyaningrün (ICG) und Nahinfrarot (NIR)-Kamerasystem kommuniziert. Im Vergleich zur konventionellen Methode wurde die Wertigkeit des ICG-/NIR-Verfahrens in Abhängigkeit vom Body-Mass-Index (BMI) des Patienten und der Konzentration von ICG bezüglich der Visualisierung des Lymphabstroms und des SLNs untersucht. An zehn Patienten wurde die SLNB mittels Technetium-99m, Patentblau und ICG durchgeführt. Die Fluoreszenz-Darstellung von Lymphbahnen und SLN erfolgte in Echtzeit mittels der NIR-Kameratechnik "FOVIS". Je nach erzielter Bildqualität wurde ICG in einer Dosis von 0,25 mg bis 2,5 mg intrakutan appliziert. Neun der zehn SLN wurden fluoreszenzoptisch identifiziert (90 %), alle zehn radioaktiv (100 %), nur acht (80 %) mittels ICG-Grünfärbung bzw. Patenblau-Markierung. Transdermal wurde ein SLN dargestellt (10 %). In Korrelation zum BMI waren höhere ICG-Mengen, bis zu 2,5 mg intrakutan absolut, in der Darstellung der Lymphbahnen von Vorteil. Die SLN-Fluoreszenzmarkierung mit dem ICG/NIR-Kamera-System "FOVIS" stellt eine sichere Alternative zur Farbstoffmethode mit Patentblau ergänzend zur Radiokolloidmethode mit Technetium-99m dar. Weitere Studien zur optimalen Dosierung von ICG und transdermalen Bildgebung in Relation zum BMI sind notwendig. © 2017 Deutsche Dermatologische Gesellschaft (DDG). Published by John Wiley & Sons Ltd.
NASA Astrophysics Data System (ADS)
Parmar, J. H.; Bhartiya, Sharad; Venkatesh, K. V.
2009-09-01
Adaptation to osmotic shock in Saccharomyces cerevisiae is brought about by the activation of two independent signaling pathways, Sho1 and Sln1, which in turn trigger the high osmolarity glycerol (HOG) pathway. The HOG pathway thereby activates the transcription of Gpd1p, an enzyme necessary to synthesize glycerol. The production of glycerol brings about a change in the intracellular osmolarity leading to adaptation. We present a detailed mechanistic model for the response of the yeast to hyperosmotic shock. The model integrates the two branches, Sho1 and Sln1, of the HOG pathway and also includes the mitogen-activated protein kinase cascade, gene regulation and metabolism. Model simulations are consistent with known experimental results for wild-type strain, and Ste11Δ and Ssk1Δ mutant strains subjected to osmotic stress. Simulation results predict that both the branches contribute to the overall wild-type response for moderate osmotic shock, while under severe osmotic shock, the cell responds mainly through the Sln1 branch. The analysis shows that the Sln1 branch helps the cell in preventing cross-talk to other signaling pathways by inhibiting ste11ste50 activation and also by increasing the phosphorylation of Ste50. We show that the negative feedbacks to the Sho1 branch must be faster than those to the Sln1 branch to simultaneously achieve pathway specificity and adaptation during hyperosmotic shock. Sensitivity analysis revealed that the presence of both branches imparts robust behavior to the cell under osmoadaptation to perturbations.
ERIC Educational Resources Information Center
Park-Martinez, Jayne Irene
2011-01-01
The purpose of this study was to assess the effects of node-link mapping on students' meaningful learning and conceptual change in a 1-semester introductory life-science course. This study used node-link mapping to integrate and apply the National Research Council's (NRC, 2005) three principles of human learning: engaging students' prior…
Xie, ShuYu; Wang, SiLiang; Zhao, BaoKai; Han, Chao; Wang, Ming; Zhou, WenZhong
2008-12-01
Most proteins are hydrophilic and poorly encapsulated into the hydrophobic matrix of solid lipid nanoparticles (SLN). To solve this problem, poly (lactic-co-glycolic acid) (PLGA) was utilized as a lipophilic polymeric emulsifier to prepare hydrophilic protein-loaded SLN by w/o/w double emulsion and solvent evaporation techniques. Hydrogenated castor oil (HCO) was used as a lipid matrix and bovine serum albumin (BSA), lysozyme and insulin were used as model proteins to investigate the effect of PLGA on the formulation of the SLN. The results showed that PLGA was essential for the primary w/o emulsification. In addition, the stability of the w/o emulsion, the encapsulation efficiency and loading capacity of the nanoparticles were enhanced with the increase of PLGA concentration. Furthermore, increasing PLGA concentration decreased zeta potential significantly but had no influence on particle size of the SLN. In vitro release study showed that PLGA significantly affected the initial burst release, i.e. the higher the content of PLGA, the lower the burst release. The released proteins maintained their integrity and bioactivity as confirmed by sodium dodecyl sulphate-polyacrylamide gel electrophoresis (SDS-PAGE) and biological assay. These results demonstrated that PLGA was an effective emulsifier for the preparation of hydrophilic protein-loaded SLN.
Attama, A A; Müller-Goymann, C C
2007-04-04
There is increasing interest in the search for improved drug delivery systems with greater versatility. Consequently, many drug delivery systems have been studied. In this study, surface-modified lipid nanocontainers were formulated with a homolipid from Capra hircus (goat fat) templated with a heterolipid (Phospholipon 90G) which was also the surface modifier. The solid lipid nanocontainers (SLN) were formulated by hot high pressure homogenisation using increasing concentrations of polysorbate 80 as the mobile surfactant. Prior to SLN preparation, the templated homolipid was formulated by fusion to obtain a homogeneous lipid matrix, which was characterized using differential scanning calorimetry (DSC), polarized light microscopy (PLM) and wide angle X-ray diffraction (WAXD) to obtain its thermal and crystal characteristics. Isothermal heat conduction microcalorimetry (IMC) and freeze-fracture transmission electron microscopy (FFTEM) studies were carried out on the templated homolipid and SLN containing 1.0% (w/w) of polysorbate 80 to study their in situ crystallization kinetics and morphology, respectively. The formulated SLN were also subjected to time-resolved DSC, WAXD and particle size analyses for one month. The thermal and crystal characteristics were compared with those of the bulk lipid matrix (templated homolipid). Result of the particle size analysis indicated that the particles size remained roughly within the lower nanometer range after one month. FFTEM micrograph of the lipid matrices revealed lamellar sheets for Phospholipon 90G and layered triglyceride structures for the homolipid and Phospholipon 90G-templated homolipid. FFTEM micrograph of SLN revealed anisometric structures. PLM of the templated homolipid did not show, but goat fat (homolipid) alone showed slight growth in crystals with time. WAXD and DSC studies revealed minor increase in crystallinity of the new lipid matrix after one month and DSC also detected templation of homolipid by the heterolipid noted by the disappearance of the lower melting peak of the homolipid. However, for the SLN, WAXD results showed low crystalline particles while DSC only showed a very little endothermic process after one month of storage at 20 degrees C. The implication of this finding is that progression of the SLN to highly ordered particles over time would not occur. This will be favourable for any incorporated drug as drug expulsion, due to increase in crystallinity, will not occur. Result obtained from analysis of the isothermal crystallization exotherms indicated that the templated homolipid and SLN1 containing 1.0% polysorbate 80 possess similar nucleation mechanisms and growth dimensions different from the pure homolipid. The SLN containing 0.5 and 1.0% polysorbate 80 possessed good properties and could prove to be good delivery systems for drugs for parenteral or ocular administration. The result of this study also shows a method of improving natural lipids for use in particulate drug delivery systems.
Gupta, Biki; Poudel, Bijay Kumar; Pathak, Shiva; Tak, Jin Wook; Lee, Hee Hyun; Jeong, Jee-Heon; Choi, Han-Gon; Yong, Chul Soon; Kim, Jong Oh
2016-06-01
Imatinib (IMT), an anticancer agent, inhibits receptor tyrosine kinases and is characterized by poor aqueous solubility, extensive first-pass metabolism, and rapid clearance. The aims of the current study are to prepare imatinib-loaded solid lipid nanoparticles (IMT-SLN) and study the effects of associated formulation variables on particle size and drug encapsulation on IMT-SLN using an experimental design. IMT-SLN was optimized by use of a "combo" approach involving Plackett-Burman design (PBD) and Box-Behnken design (BBD). PBD screening resulted in the determination of organic-to-aqueous phase ratio (O/A), drug-to-lipid ratio (D/L), and amount of Tween® 20 (Tw20) as three significant variables for particle size (S z), drug loading (DL), and encapsulation efficiency (EE) of IMT-SLN, which were used for optimization by BBD, yielding an optimized criteria of O/A = 0.04, D/L = 0.03, and Tw20 = 2.50% w/v. The optimized IMT-SLN exhibited monodispersed particles with a size range of 69.0 ± 0.9 nm, ζ-potential of -24.2 ± 1.2 mV, and DL and EE of 2.9 ± 0.1 and 97.6 ± 0.1% w/w, respectively. Results of in vitro release study showed a sustained release pattern, presumably by diffusion and erosion, with a higher release rate at pH 5.0, compared to pH 7.4. In conclusion, use of the combo experimental design approach enabled clear understanding of the effects of various formulation variables on IMT-SLN and aided in the preparation of a system which exhibited desirable physicochemical and release characteristics.
Elkomy, Mohammed H; Elmenshawe, Shahira F; Eid, Hussein M; Ali, Ahmed M A
2016-11-01
This work aimed at investigating the potential of solid lipid nanoparticles (SLN) as carriers for topical delivery of Ketoprofen (KP); evaluating a novel technique incorporating Artificial Neural Network (ANN) and clustered bootstrap for optimization of KP-loaded SLN (KP-SLN); and demonstrating a longitudinal dose response (LDR) modeling-based approach to compare the activity of topical non-steroidal anti-inflammatory drug formulations. KP-SLN was fabricated by a modified emulsion/solvent evaporation method. Box-Behnken design was implemented to study the influence of glycerylpalmitostearate-to-KP ratio, Tween 80, and lecithin concentrations on particle size, entrapment efficiency, and amount of drug permeated through rat skin in 24 hours. Following clustered bootstrap ANN optimization, the optimized KP-SLN was incorporated into an aqueous gel and evaluated for rheology, in vitro release, permeability, skin irritation and in vivo activity using carrageenan-induced rat paw edema model and LDR mathematical model to analyze the time course of anti-inflammatory effect at various application durations. Lipid-to-drug ratio of 7.85 [bootstrap 95%CI: 7.63-8.51], Tween 80 of 1.27% [bootstrap 95%CI: 0.601-2.40%], and Lecithin of 0.263% [bootstrap 95%CI: 0.263-0.328%] were predicted to produce optimal characteristics. Compared with profenid® gel, the optimized KP-SLN gel exhibited slower release, faster permeability, better texture properties, greater efficacy, and similar potency. SLNs are safe and effective permeation enhancers. ANN coupled with clustered bootstrap is a useful method for finding optimal solutions and estimating uncertainty associated with them. LDR models allow mechanistic understanding of comparative in vivo performances of different topical formulations, and help design efficient dermatological bioequivalence assessment methods.
The central projections of the laryngeal nerves in the rat
Pascual-Font, Arán; Hernández-Morato, Ignacio; McHanwell, Stephen; Vázquez, Teresa; Maranillo, Eva; Sañudo, Jose; Valderrama-Canales, Francisco J
2011-01-01
The larynx serves respiratory, protective, and phonatory functions. The motor and sensory innervation to the larynx controlling these functions is provided by the superior laryngeal nerve (SLN) and the recurrent laryngeal nerve (RLN). Classical studies state that the SLN innervates the cricothyroid muscle and provides sensory innervation to the supraglottic cavity, whereas the RLN supplies motor innervation to the remaining intrinsic laryngeal muscles and sensory innervation to the infraglottic cavity, but recent data suggest a more complex anatomical and functional organisation. The current neuroanatomical tracing study was undertaken to provide a comprehensive description of the central brainstem connections of the axons within the SLN and the RLN, including those neurons that innervate the larynx. The study has been carried out in 41 adult male Sprague–Dawley rats. The central projections of the laryngeal nerves were labelled following application of biotinylated dextran amines onto the SLN, the RLN or both. The most remarkable result of the study is that in the rat the RLN does not contain any afferent axons from the larynx, in contrast to the pattern observed in many other species including man. The RLN supplied only special visceromotor innervation to the intrinsic muscles of the larynx from motoneurons in the nucleus ambiguus (Amb). All the afferent axons innervating the larynx are contained within the SLN, and reach the nucleus of the solitary tract. The SLN also contained secretomotor efferents originating from motoneurons in the dorsal motor nucleus of the vagus, and special visceral efferent fibres from the Amb. In conclusion, the present study shows that in the rat the innervation of the larynx differs in significant ways from that described in other species. PMID:21599662
Thakkar, Arvind; Chenreddy, Sushma; Thio, Astrid; Khamas, Wael; Wang, Jeffrey; Prabhu, Sunil
2016-01-01
Our previous studies have established the efficacy of chemopreventive regimens of aspirin and curcumin (CUR) encapsulated within solid lipid nanoparticles (SLNs) in combination with free sulforaphane (ACS combination) to prevent or delay the initiation and progression of pancreatic cancer, classified as one of the deadliest diseases with very low chances of survival upon diagnosis. Although toxicity of individual drugs and SLN has been studied previously, there are no studies in current literature that evaluate the potential toxicity of a combined regimen of ACS, especially when encapsulated within chitosan-SLNs (c-SLNs). Hence, objective of the current study was to investigate the potential toxic effects of ACS c-SLN combined chemopreventive regimens following acute (3 days), subacute (28 days), and subchronic (90 days) administrations by oral gavage in BALB/c mice. Mice were administered the following regimens: saline, blank c-SLN, low-dose ACS c-SLN (2+4.5+0.16 mg/kg), medium-dose ACS c-SLN (20+45+1.6 mg/kg), and high-dose ACS c-SLN (60+135+4.8 mg/kg). The potential toxicity was evaluated based on animal survival, body weight, hematology, blood chemistry, and organ histopathology. During 3-day, 28-day, and 90-day study periods, no animal deaths were observed. Treatment with ACS c-SLNs did not cause alteration in complete blood counts and blood chemistry data. Histopathological examination of various organ sections (pancreas, heart, liver, kidney, and brain) appeared normal. Based on the results of this study, no signs of toxicity in acute, subacute, and subchronic studies following oral administration of ACS c-SLNs were found indicating that the oral dosing regimens were safe at the levels tested for long-term administration to prevent the onset of pancreatic cancer. PMID:27499621
Treatment of chronic neurogenic cough with in-office superior laryngeal nerve block.
Simpson, C Blake; Tibbetts, Kathleen M; Loochtan, Michael J; Dominguez, Laura M
2018-04-18
Neurogenic cough is believed to result from a sensory neuropathy involving the internal branch of the superior laryngeal nerve (SLN). We present our outcomes for the treatment of neurogenic cough with localized blockade of the internal branch of the SLN. A retrospective chart review of patients who underwent in-office percutaneous SLN block for treatment of neurogenic cough between 2015 and 2017 was conducted. Patient demographics, indications for injection, and response to treatment were recorded and analyzed. Cough severity index (CSI) scores before and after treatment were compared. Twenty-three patients underwent percutaneous blockade of the internal branch of the SLN in the clinic setting, and five patients were excluded for incomplete records. The indication was neurogenic cough as a diagnosis of exclusion. The injectable substance used was a 1:1 mixture of a long-acting particulate corticosteroid and a local anesthetic. Unilateral injections were performed in 13 patients, and five patients underwent bilateral injections. Of the unilateral injections, 10 were left-sided. Patients underwent an average of 2.4 SLN block procedures (range 1-7). Mean follow-up time postinjection was 85.4 days (7-450 days). Cough severity index scores decreased significantly from an average of 26.8 pretreatment to 14.6 posttreatment (P < 0.0001). The SLN block is an effective treatment for neurogenic cough, with average CSI scores significantly improved following injection. Further study is necessary to determine the characteristics of patients' responses to treatment, long-term outcomes, and efficacy of the procedure when compared to placebo and other accepted treatments for neurogenic cough. 4. Laryngoscope, 2018. © 2018 The American Laryngological, Rhinological and Otological Society, Inc.
Estrada, O; Pulido, L; Admella, C; Hidalgo, L-A; Clavé, P; Suñol, X
2017-04-01
Around a third of node-negative patients with colon cancer experience a recurrence after surgery, suggesting poor staging. Sentinel lymph node techniques combined with immunochemistry could improve colon cancer staging. We prospectively assessed the effect of Sentinel node mapping on staging and survival in patients with non-metastatic colon cancer. An observational and prospective study was designed. 105 patients with colon cancer were selected. Patients were classified according to node involvement as: N1, with node invasion detected by the conventional techniques; up-staged, with node invasion detected only by sentinel node mapping; and N0, with negative lymph node involvement by both techniques. Five-year survival and disease-free survival rates were analysed. Multivariate regression analyses were performed to identify prognostic factors for disease-free and overall survival. Sentinel node mapping was successfully applied in 78 patients: 33 % were N1; 24.5 % were up-staged (18 patients with isolated tumour cells and 1 patient with micrometastases); and 42.5 % were N0. N1 patients had the poorest overall 5-year survival (65.4 %) and 5-year disease-free survival (69.2 %) rates compared with the other two groups. No significant 5-year survival differences were observed between N0 patients (87.9 %) and up-staged patients (84.2 %). Patients up-staged after sentinel node mapping do not have a poorer prognosis than patients without node involvement. Detection of isolated cancer cells was not a poor prognosis factor in these patients.
Data Access Based on a Guide Map of the Underwater Wireless Sensor Network
Wei, Zhengxian; Song, Min; Yin, Guisheng; Wang, Hongbin; Cheng, Albert M. K.
2017-01-01
Underwater wireless sensor networks (UWSNs) represent an area of increasing research interest, as data storage, discovery, and query of UWSNs are always challenging issues. In this paper, a data access based on a guide map (DAGM) method is proposed for UWSNs. In DAGM, the metadata describes the abstracts of data content and the storage location. The center ring is composed of nodes according to the shortest average data query path in the network in order to store the metadata, and the data guide map organizes, diffuses and synchronizes the metadata in the center ring, providing the most time-saving and energy-efficient data query service for the user. For this method, firstly the data is stored in the UWSN. The storage node is determined, the data is transmitted from the sensor node (data generation source) to the storage node, and the metadata is generated for it. Then, the metadata is sent to the center ring node that is the nearest to the storage node and the data guide map organizes the metadata, diffusing and synchronizing it to the other center ring nodes. Finally, when there is query data in any user node, the data guide map will select a center ring node nearest to the user to process the query sentence, and based on the shortest transmission delay and lowest energy consumption, data transmission routing is generated according to the storage location abstract in the metadata. Hence, specific application data transmission from the storage node to the user is completed. The simulation results demonstrate that DAGM has advantages with respect to data access time and network energy consumption. PMID:29039757
Data Access Based on a Guide Map of the Underwater Wireless Sensor Network.
Wei, Zhengxian; Song, Min; Yin, Guisheng; Song, Houbing; Wang, Hongbin; Ma, Xuefei; Cheng, Albert M K
2017-10-17
Underwater wireless sensor networks (UWSNs) represent an area of increasing research interest, as data storage, discovery, and query of UWSNs are always challenging issues. In this paper, a data access based on a guide map (DAGM) method is proposed for UWSNs. In DAGM, the metadata describes the abstracts of data content and the storage location. The center ring is composed of nodes according to the shortest average data query path in the network in order to store the metadata, and the data guide map organizes, diffuses and synchronizes the metadata in the center ring, providing the most time-saving and energy-efficient data query service for the user. For this method, firstly the data is stored in the UWSN. The storage node is determined, the data is transmitted from the sensor node (data generation source) to the storage node, and the metadata is generated for it. Then, the metadata is sent to the center ring node that is the nearest to the storage node and the data guide map organizes the metadata, diffusing and synchronizing it to the other center ring nodes. Finally, when there is query data in any user node, the data guide map will select a center ring node nearest to the user to process the query sentence, and based on the shortest transmission delay and lowest energy consumption, data transmission routing is generated according to the storage location abstract in the metadata. Hence, specific application data transmission from the storage node to the user is completed. The simulation results demonstrate that DAGM has advantages with respect to data access time and network energy consumption.
Gamma Knife Radiosurgery of the Superior Laryngeal Neuralgia: A report of three cases.
Fu, Peng; Xiong, Nan-Xiang; Abdelmaksoud, Ahmed; Huang, Yi-Zhi; Song, Guo-Bin; Zhao, Hong-Yang
2018-05-19
Superior laryngeal neuralgia (SLN) is a relatively rare disorder that is characterized by neck pain. There are only a few reported cases and treatment options for SLN to date. In this study, we reported 3 patients with SLN who were treated with gamma knife radiosurgery (GKRS) at the time of diagnosis. For all 3 patients, GKRS was administered using a 4-mm collimator to deliver a single shot of 80 Gy of radiation (the 100% isodose line). The target was set at the jugular foramen where the vagus and glossopharyngeal nerves emerge from the skull. Follow-up assessments were performed at 32 months,31 months, and 30 months after GKRS. The 3 patients described pain relief at 3 months, 2 days and 6 weeks. None of the patients developed neurological deficits during the follow-up period. This preliminary report provides encouraging evidence that GKRS represents an effective, safe and relatively durable noninvasive treatment option for patients with SLN. Copyright © 2018 Elsevier Inc. All rights reserved.
Experimental anti-GBM nephritis as an analytical tool for studying spontaneous lupus nephritis.
Du, Yong; Fu, Yuyang; Mohan, Chandra
2008-01-01
Systemic lupus erythematosus (SLE) is an autoimmune disease that results in immune-mediated damage to multiple organs. Among these, kidney involvement is the most common and fatal. Spontaneous lupus nephritis (SLN) in mouse models has provided valuable insights into the underlying mechanisms of human lupus nephritis. However, SLN in mouse models takes 6-12 months to manifest; hence there is clearly the need for a mouse model that can be used to unveil the pathogenic processes that lead to immune nephritis over a shorter time frame. In this article more than 25 different molecules are reviewed that have been studied both in the anti-glomerular basement membrane (anti-GBM) model and in SLN and it was found that these molecules influence both diseases in a parallel fashion, suggesting that the two disease settings share common molecular mechanisms. Based on these observations, the authors believe the experimental anti-GBM disease model might be one of the best tools currently available for uncovering the downstream molecular mechanisms leading to SLN.
Formulation and evaluation of chitosan solid lipid nanoparticles of carbamazepine.
Nair, Rahul; Kumar, Ashok C K; Priya, Vishnu K; Yadav, Chakrapani M; Raju, Prasanna Y
2012-06-13
The present work aims at preparing aqueous suspension of Solid lipid Nanoparticles containing Chitosan (CT) which is a biopolymer that exhibits a number of interesting properties which include controlled drug delivery. Carbamezapine (CBZ) is a lipophilic drug which shows it antiepileptic activity by inactivating sodium channels. The solid lipid Nanoparticles (SLN) of Chitosan-CBZ were prepared by using solvent injection method using ethanol as organic solvent. The prepared SLN formulations exhibited high encapsulation efficiency, high physical stability. The drug incorporated SLNs have demonstrated that the controlled release patterns of the drug for prolonged period. The prepared SLNs were characterized for surface morphology by SEM analysis, entrapment efficiency, zeta potential, FTIR, DSC and In-vitro diffusion studies. The hydrodynamic mean diameter and zeta potential were 168.7 ± 1.8 nm and -28.9 ± 2.0 mV for SLN-chitosan-CBZ respectively. Therefore chitosan-SLN can be good candidates to encapsulate CBZ and to increase its therapeutic efficacy in the treatment of Epilepsy.
Formulation and evaluation of chitosan solid lipid nanoparticles of carbamazepine
2012-01-01
The present work aims at preparing aqueous suspension of Solid lipid Nanoparticles containing Chitosan (CT) which is a biopolymer that exhibits a number of interesting properties which include controlled drug delivery. Carbamezapine (CBZ) is a lipophilic drug which shows it antiepileptic activity by inactivating sodium channels. The solid lipid Nanoparticles (SLN) of Chitosan-CBZ were prepared by using solvent injection method using ethanol as organic solvent. The prepared SLN formulations exhibited high encapsulation efficiency, high physical stability. The drug incorporated SLNs have demonstrated that the controlled release patterns of the drug for prolonged period. The prepared SLNs were characterized for surface morphology by SEM analysis, entrapment efficiency, zeta potential, FTIR, DSC and In-vitro diffusion studies. The hydrodynamic mean diameter and zeta potential were 168.7 ±1.8 nm and −28.9 ±2.0 mV for SLN-chitosan-CBZ respectively. Therefore chitosan-SLN can be good candidates to encapsulate CBZ and to increase its therapeutic efficacy in the treatment of Epilepsy. PMID:22695222
NASA Astrophysics Data System (ADS)
Hoffman, Joanne; Liu, Jiamin; Turkbey, Evrim; Kim, Lauren; Summers, Ronald M.
2015-03-01
Station-labeling of mediastinal lymph nodes is typically performed to identify the location of enlarged nodes for cancer staging. Stations are usually assigned in clinical radiology practice manually by qualitative visual assessment on CT scans, which is time consuming and highly variable. In this paper, we developed a method that automatically recognizes the lymph node stations in thoracic CT scans based on the anatomical organs in the mediastinum. First, the trachea, lungs, and spines are automatically segmented to locate the mediastinum region. Then, eight more anatomical organs are simultaneously identified by multi-atlas segmentation. Finally, with the segmentation of those anatomical organs, we convert the text definitions of the International Association for the Study of Lung Cancer (IASLC) lymph node map into patient-specific color-coded CT image maps. Thus, a lymph node station is automatically assigned to each lymph node. We applied this system to CT scans of 86 patients with 336 mediastinal lymph nodes measuring equal or greater than 10 mm. 84.8% of mediastinal lymph nodes were correctly mapped to their stations.
Fancher, Crystal E; Scott, Anthony; Allen, Ahkeel; Dale, Paul
2017-08-01
this is a 10-year retrospective chart review evaluating the potential impact of the most recent American Cancer Society mammography screening guidelines which excludes female patients aged 40 to 44 years from routine annual screening mammography. Instead they recommend screening mammography starting at age 45 with the option to begin screening earlier if the patient desires. The institutional cancer registry was systematically searched to identify all women aged 40 to 44 years treated for breast cancer over a 10-year period. These women were separated into two cohorts: screening mammography detected cancer (SMDC) and nonscreening mammography detected cancer (NSMDC). Statistical analysis of the cohorts was performed for lymph node status (SLN), five-year disease-free survival, and five-year overall survival. Women with SMDC had a significantly lower incidence of SLN positive cancer than the NSMDC group, 9 of 63 (14.3%) versus 36 of 81 (44 %; P < 0.001). The five-year disease-free survival for both groups was 84 per cent for SMDC and 80 per cent for NSMDC; this was not statistically significant. The five-year overall survival was statistically significant at 94 per cent for the SMDC group and 80 per cent for the NSMDC group (P < 0.05). This review demonstrates the significance of mammographic screening for early detection and treatment of breast cancer. Mammographic screening in women aged 40 to 44 detected tumors with fewer nodal metastases, resulting in improved survival and reaffirming the need for annual mammographic screening in this age group.
Paley, Pamela J; Veljovich, Dan S; Press, Joshua Z; Isacson, Christina; Pizer, Ellen; Shah, Chirag
2016-07-01
The accuracy of sentinel lymph node mapping has been shown in endometrial cancer, but studies to date have primarily focused on cohorts at low risk for nodal involvement. In our practice, we acknowledge the lack of benefit of lymphadenectomy in the low-risk subgroup and omit lymph node removal in these patients. Thus, our aim was to evaluate the feasibility and accuracy of sentinel node mapping in women at sufficient risk for nodal metastasis warranting lymphadenectomy and in whom the potential benefit of avoiding nodal procurement could be realized. To evaluate the detection rate and accuracy of fluorescence-guided sentinel lymph node mapping in endometrial cancer patients undergoing robotic-assisted staging. One hundred twenty-three endometrial cancer patients undergoing sentinel lymph node sentinel node mapping using indocyanine green were prospectively evaluated. Two mL (1.0 mg/mL) of dye were injected into the cervical stroma divided between the 2-3 and 9-10 o'clock positions at the time of uterine manipulator placement. Before hysterectomy, the retroperitoneal spaces were developed and fluorescence imaging was used for sentinel node detection. Identified sentinel nodes were removed and submitted for touch prep intraoperatively, followed by permanent assessment with routine hematoxylin and eosin levels. Patients then underwent hysterectomy, bilateral salpingo-oophorectomy, and completion bilateral pelvic and periaortic lymphadenectomy based on intrauterine risk factors determined intraoperatively (tumor size >2 cm, >50% myometrial invasion, and grade 3 histology). Of 123 patients enrolled, at least 1 sentinel node was detected in 119 (96.7%). Ninety-nine patients (80%) had bilateral pelvic or periaortic sentinel nodes detected. A total of 85 patients met criteria warranting completion lymphadenectomy. In 14 patients (16%) periaortic lymphadenectomy was not feasible, and the mean number of pelvic nodes procured was 13 (6-22). Of the 71 patients undergoing pelvic and periaortic lymphadenectomy, the mean nodal count was 23.2 (8-51). Of patients undergoing lymphadenectomy, 10.6% had lymph node metastasis on final hematoxylin and eosin evaluation. Notably, the sentinel node was the only positive node in 44% of cases. There were no cases in which final pathology of the sentinel node was negative and metastatic disease was detected upon completion lymphadenectomy in the non-sentinel nodes (no false negatives), yielding a sensitivity of 100%. Of the 14 sentinel nodes ultimately found to harbor metastases, 3 were negative on touch prep, yielding a sensitivity of 78.6% for intraoperative detection of sentinel node involvement. In all 3 of the false-negative touch preps, final pathology detected a single micrometastasis (0.24 mm, 1.4 mm, 1.5 mm). As expected, there were no false-positive results, yielding a specificity of 100%. No complications related to sentinel node mapping or allergic reactions to the dye were encountered. Intraoperative sentinel node mapping using fluorescence imaging with indocyanine green in endometrial cancer patients is feasible and yields high detection rates. In our pilot study, sentinel node mapping identified all women with Stage IIIC disease. Low false-negative rates are encouraging, and if confirmed in multi-institutional trials, this approach would be anticipated to reduce the morbidity, operative times, and costs associated with complete pelvic and periaortic lymphadenectomy. Copyright © 2015 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Meng, Xiang-Ping; Wang, Xiao; Wang, Huai-ling; Chen, Tong-sheng; Wang, Yi-fei; Wang, Zhi-ping
2016-03-01
Hepatocarcinoma and esophageal squamous cell carcinomas threaten human life badly. It is a current issue to seek the effective natural remedy from plant to treat cancer due to the resistance of the advanced hepatocarcinoma and esophageal carcinoma to chemotherapy. Berberine (Ber), an isoquinoline derivative alkaloid, has a wide range of pharmacological properties and is considered to have anti-hepatocarcinoma and antiesophageal carcinoma effects. However its low oral bioavailability restricts its wide application. In this report, Ber loaded solid lipid nanoparticles (Ber-SLN) was prepared by hot melting and then high pressure homogenization technique. The in vitro anti-hepatocarcinoma and antiesophageal carcinoma effects of Ber-SLN relative to efficacy of bulk Ber were evaluated. The particle size and zeta potential of Ber-SLN were 154.3 ± 4.1 nm and -11.7 ± 1.8 mV, respectively. MTT assay showed that Ber-SLN effectively inhibited the proliferation of human HepG2 and Huh7 and EC9706 cells, and the corresponding IC50 value was 10.6 μg/ml, 5.1 μg/ml, and 7.3 μg/ml (18.3μg/ml, 6.5μg/ml, and 12.4μg/ml μg/ml of bulk Ber solution), respectively. These results suggest that the delivery of Ber-SLN is a promising approach for treating tumors.
Sun, Qi-Jian; Bautista, Tara G; Berkowitz, Robert G; Zhao, Wen-Jing; Pilowsky, Paul M
2011-01-01
Abstract A striking effect of stimulating the superior laryngeal nerve (SLN) is its ability to inhibit central inspiratory activity (cause ‘phrenic apnoea’), but the mechanism underlying this inhibition remains unclear. Here we demonstrate, by stimulating the SLN at varying frequencies, that the evoked non-respiratory burst activity recorded from expiratory laryngeal motoneurons (ELMs) has an intimate temporal relationship with phrenic apnoea. During 1–5 Hz SLN stimulation, occasional absences of phrenic nerve discharge (PND) occurred such that every absent PND was preceded by an ELM burst activity. During 10–20 Hz SLN stimulation, more bursts were evoked together with more absent PNDs, leading eventually to phrenic apnoea. Interestingly, subsequent microinjections of isoguvacine (10 mm, 20–40 nl) into ipsilateral Bötzinger complex (BötC) and contralateral nucleus tractus solitarii (NTS) significantly attenuated the apnoeic response but not the ELM burst activity. Our results suggest a bifurcating projection from NTS to both the caudal nucleus ambiguus and BötC, which mediates the closely related ELM burst and apnoeic response, respectively. We believe that such an intimate timing between laryngeal behaviour and breathing is crucial for the effective elaboration of the different airway protective behaviours elicited following SLN stimulation, including the laryngeal adductor reflex, swallowing and cough. PMID:21320890
Roxithromycin-loaded lipid nanoparticles for follicular targeting.
Wosicka-Frąckowiak, Hanna; Cal, Krzysztof; Stefanowska, Justyna; Główka, Eliza; Nowacka, Magdalena; Struck-Lewicka, Wiktoria; Govedarica, Biljana; Pasikowska, Monika; Dębowska, Renata; Jesionowski, Teofil; Srčič, Stane; Markuszewski, Michał Jan
2015-11-30
Particulate drug carriers e.g. nanoparticles (NPs) have been shown to penetrate and accumulate preferentially in skin hair follicles creating high local concentration of a drug. In order to develop such a follicle targeting system we obtained and characterized solid lipid nanoparticles (SLN) loaded with roxithromycin (ROX). The mean particle size (172±2 nm), polydisperisty index (0.237±0.007), zeta potential (-31.68±3.10 mV) and incorporation efficiency (82.1±3.0%) were measured. The long term stability of ROX-loaded SLN suspensions was proved up to 26 weeks. In vitro drug release study was performed using apparatus 4 dialysis adapters. Skin irritation test conducted using the EpiDerm™ tissue model demonstrated no irritation potential for ROX-loaded SLN. Ex vivo human skin penetration studies, employing rhodamine B hexyl ester perchlorate (RBHE) as a fluorescent dye to label the particles, revealed fluorescence deep in the skin, specifically around the hair follicles up to over 1mm depth. The comparison of fluorescence intensities after application of RBHE solution and RBHE-labelled ROX-loaded SLN was done. Then cyanoacrylate follicular biopsies were obtained in vivo and analyzed for ROX content, proving the possibility of penetration to human pilosebaceous units and delivering ROX by using SLN with the size below 200 nm. Copyright © 2015 Elsevier B.V. All rights reserved.
Sabel, Michael S; Rice, John D; Griffith, Kent A; Lowe, Lori; Wong, Sandra L; Chang, Alfred E; Johnson, Timothy M; Taylor, Jeremy M G
2012-01-01
To identify melanoma patients at sufficiently low risk of nodal metastases who could avoid sentinel lymph node biopsy (SLNB), several statistical models have been proposed based upon patient/tumor characteristics, including logistic regression, classification trees, random forests, and support vector machines. We sought to validate recently published models meant to predict sentinel node status. We queried our comprehensive, prospectively collected melanoma database for consecutive melanoma patients undergoing SLNB. Prediction values were estimated based upon four published models, calculating the same reported metrics: negative predictive value (NPV), rate of negative predictions (RNP), and false-negative rate (FNR). Logistic regression performed comparably with our data when considering NPV (89.4 versus 93.6%); however, the model's specificity was not high enough to significantly reduce the rate of biopsies (SLN reduction rate of 2.9%). When applied to our data, the classification tree produced NPV and reduction in biopsy rates that were lower (87.7 versus 94.1 and 29.8 versus 14.3, respectively). Two published models could not be applied to our data due to model complexity and the use of proprietary software. Published models meant to reduce the SLNB rate among patients with melanoma either underperformed when applied to our larger dataset, or could not be validated. Differences in selection criteria and histopathologic interpretation likely resulted in underperformance. Statistical predictive models must be developed in a clinically applicable manner to allow for both validation and ultimately clinical utility.
Contrast-enhanced ultrasound mapping of sentinel lymph nodes in oral tongue cancer-a pilot study.
Gvetadze, Shalva R; Xiong, Ping; Lv, Mingming; Li, Jun; Hu, Jingzhou; Ilkaev, Konstantin D; Yang, Xin; Sun, Jian
2017-03-01
To assess the usefulness of contrast-enhanced ultrasound (CEUS) with peritumoral injection of microbubble contrast agent for detecting the sentinel lymph nodes for oral tongue carcinoma. The study was carried out on 12 patients with T1-2cN0 oral tongue cancer. A radical resection of the primary disease was planned; a modified radical supraomohyoid neck dissection was reserved for patients with larger lesions (T2, n = 8). The treatment plan and execution were not influenced by sentinel node mapping outcome. The Sonovue ™ contrast agent (Bracco Imaging, Milan, Italy) was utilized. After detection, the position and radiologic features of the sentinel nodes were recorded. The identification rate of the sentinel nodes was 91.7%; one patient failed to demonstrate any enhanced areas. A total of 15 sentinel nodes were found in the rest of the 11 cases, with a mean of 1.4 nodes for each patient. The sentinel nodes were localized in: Level IA-1 (6.7%) node; Level IB-11 (73.3%) nodes; Level IIA-3 (20.0%) nodes. No contrast-related adverse effects were observed. For oral tongue tumours, CEUS is a feasible and potentially widely available approach of sentinel node mapping. Further clinical research is required to establish the position of CEUS detection of the sentinel nodes in oral cavity cancers.
A critical assessment on the role of sentinel node mapping in endometrial cancer.
Bogani, Giorgio; Ditto, Antonino; Martinelli, Fabio; Signorelli, Mauro; Perotto, Stefania; Lorusso, Domenica; Raspagliesi, Francesco
2015-10-01
Endometrial cancer is the most common gynecologic malignancy in the developed countries. Although the high incidence of this occurrence no consensus, about the role of retroperitoneal staging, still exists. Growing evidence support the safety and efficacy of sentinel lymph node mapping. This technique is emerging as a new standard for endometrial cancer staging procedures. In the present paper, we discuss the role of sentinel lymph node mapping in endometrial cancer, highlighting the most controversies features.
Multi Robot Path Planning for Budgeted Active Perception with Self-Organising Maps
2016-10-04
Multi- Robot Path Planning for Budgeted Active Perception with Self-Organising Maps Graeme Best1, Jan Faigl2 and Robert Fitch1 Abstract— We propose a...optimise paths for a multi- robot team that aims to maximally observe a set of nodes in the environment. The selected nodes are observed by visiting...regions, each node has an observation reward, and the robots are constrained by travel budgets. The SOM algorithm jointly selects and allocates nodes
Solid lipid nanoparticles for enhancing vinpocetine's oral bioavailability.
Luo, YiFan; Chen, DaWei; Ren, LiXiang; Zhao, XiuLi; Qin, Jing
2006-08-10
An ultrasonic-solvent emulsification technique was adopted to prepare vinpocetine loaded Glyceryl monostearate (GMS) nanodispersions with narrow size distribution. To increase the lipid load the process was conducted at 50 degrees C, and in order to prepare nanoparticle using an ultrasonic-solvent emulsification technique. The mean particle size and droplet size distribution, drug loading capacity, drug entrapment efficiency (EE%), zeta potential, and long-term physical stability of the SLNs were investigated in detail respectively. Drug release from two sorts of VIN-SLN was studied using a dialysis bag method. A pharmacokinetic study was conducted in male rats after oral administration of 10 mg kg(-1) VIN in different formulations, it was found that the relative bioavailability of VIN in SLNs was significantly increased compared with that of the VIN solution. The amount of surfactant also had a marked effect on the oral absorption of VIN with SLN formulations. The absorption mechanism of the SLN formulations was also discussed. These results indicated that VIN absorption is enhanced significantly by employing SLN formulations. SLNs offer a new approach to improve the oral bioavailability of poorly soluble drugs.
Narala, Arjun; Veerabrahma, Kishan
2013-01-01
Quetiapine fumarate is an antipsychotic drug with poor oral bioavailability (9%) due to first-pass metabolism. Present work is an attempt to improve oral bioavailability of quetiapine fumarate by incorporating in solid lipid nanoparticles (SLN). Six quetiapine fumarate SLN formulations were developed using three different lipids by hot homogenisation followed by ultrasonication. The drug excipient compatibility was studied by differential scanning calorimetry (DSC). Stable quetiapine fumarate SLNs having a mean particle size of 200–250 nm with entrapment efficiency varying in between 80% and 92% were developed. The physical stability of optimized formulation F3 was checked at room temperature for 2 months. Comparative bioavailability studies were conducted in male Wistar rats after oral administration of quetiapine fumarate suspension and SLN formulation. The relative bioavailability of quetiapine fumarate from optimized SLN preparation was increased by 3.71 times when compared with the reference quetiapine fumarate suspension. The obtained results are indicative of SLNs as potential lipid carriers for improving the bioavailability of quetiapine fumarate by minimizing first-pass metabolism. PMID:26555970
Hao, Jifu; Fang, Xinsheng; Zhou, Yanfang; Wang, Jianzhu; Guo, Fengguang; Li, Fei; Peng, Xinsheng
2011-01-01
The purpose of the present study was to optimize a solid lipid nanoparticle (SLN) of chloramphenicol by investigating the relationship between design factors and experimental data using response surface methodology. A Box-Behnken design was constructed using solid lipid (X(1)), surfactant (X(2)), and drug/lipid ratio (X(3)) level as independent factors. SLN was successfully prepared by a modified method of melt-emulsion ultrasonication and low temperature-solidification technique using glyceryl monostearate as the solid lipid, and poloxamer 188 as the surfactant. The dependent variables were entrapment efficiency (EE), drug loading (DL), and turbidity. Properties of SLN such as the morphology, particle size, zeta potential, EE, DL, and drug release behavior were investigated, respectively. As a result, the nanoparticle designed showed nearly spherical particles with a mean particle size of 248 nm. The polydispersity index of particle size was 0.277 ± 0.058 and zeta potential was -8.74 mV. The EE (%) and DL (%) could reach up to 83.29% ± 1.23% and 10.11% ± 2.02%, respectively. In vitro release studies showed a burst release at the initial stage followed by a prolonged release of chloramphenicol from SLN up to 48 hours. The release kinetics of the optimized formulation best fitted the Peppas-Korsmeyer model. These results indicated that the chloramphenicol-loaded SLN could potentially be exploited as a delivery system with improved drug entrapment efficiency and controlled drug release.
NASA Astrophysics Data System (ADS)
Patro, Nagaraju M.; Devi, Kshama; Pai, Roopa S.; Suresh, Sarasija
2013-12-01
We investigated the bioavailability, efficacy, and toxicity of doxorubicin-loaded solid lipid nanoparticles (DOX-SLNs) prepared by a simple modified double-emulsification method. A 3-factor, 3-level Box-Behnken statistical design was adopted in the optimization of DOX-SLN formulation considering dependent factors particle size and entrapment efficiency. Optimized SLN formulation composed of lipid (2 %) consisting of soya lecithin and Precirol ATO 5 (1:3) with Pluronic F68 (0.3 %) resulted in 217.36 ± 3.31 nm particle size and 59.45 ± 1.75 % entrapment efficiency. DOX-SLN exhibited significant enhancement ( p < 0.05) in bioavailability as compared with free DOX in Sprague-Dawley (SD) rats. DOX-SLN exhibited higher peak plasma concentration (6.761 ± 0.08 vs. 2.412 ± 0.04 μg/ml), increased AUC (61.368 ± 3.54 vs. 5.812 ± 0.49 μg/ml h), decreased clearance (36 ± 0.01 vs. 619 ± 0.005 mL/h kg), and volume of distribution (733 ± 0.092 vs. 2,064 ± 0.061 mL/kg) when compared to free DOX. The collective results of cardiac and kidney enzyme assay, antioxidant enzyme levels, hematological parameters, effect on body weight and tumor volume, tumor necrosis factor-α level, histopathological examination, and survival analysis confirmed the improved efficacy and safety profile of DOX-SLN in 7,12-dimethyl benzanthracene-induced breast cancer in SD rats.
Hao, Jifu; Fang, Xinsheng; Zhou, Yanfang; Wang, Jianzhu; Guo, Fengguang; Li, Fei; Peng, Xinsheng
2011-01-01
The purpose of the present study was to optimize a solid lipid nanoparticle (SLN) of chloramphenicol by investigating the relationship between design factors and experimental data using response surface methodology. A Box-Behnken design was constructed using solid lipid (X1), surfactant (X2), and drug/lipid ratio (X3) level as independent factors. SLN was successfully prepared by a modified method of melt-emulsion ultrasonication and low temperature-solidification technique using glyceryl monostearate as the solid lipid, and poloxamer 188 as the surfactant. The dependent variables were entrapment efficiency (EE), drug loading (DL), and turbidity. Properties of SLN such as the morphology, particle size, zeta potential, EE, DL, and drug release behavior were investigated, respectively. As a result, the nanoparticle designed showed nearly spherical particles with a mean particle size of 248 nm. The polydispersity index of particle size was 0.277 ± 0.058 and zeta potential was −8.74 mV. The EE (%) and DL (%) could reach up to 83.29% ± 1.23% and 10.11% ± 2.02%, respectively. In vitro release studies showed a burst release at the initial stage followed by a prolonged release of chloramphenicol from SLN up to 48 hours. The release kinetics of the optimized formulation best fitted the Peppas–Korsmeyer model. These results indicated that the chloramphenicol-loaded SLN could potentially be exploited as a delivery system with improved drug entrapment efficiency and controlled drug release. PMID:21556343
Varia, Jigisha K; Dodiya, Shamsunder S; Sawant, Krutika K
2008-01-01
Solid lipid nanoparticles (SLNs) loaded with Cyclosporine A using glyceryl monostearate (GMS) and glyceryl palmitostearate (GPS) as lipid matrices were prepared by melt-homogenization using high-pressure homogenizer. Various process parameters such as homogenization pressure, homogenization cycles and formulation parameters such as ratio of drug: lipid, emulsifier: lipid and emulsifier: co-emulsifier were optimized using particle size and entrapment efficiencies as the dependent variables. The mean particle size of optimized batches of the GMS SLN and GPS SLN were found to be 131 nm and 158 nm and their entrapment efficiencies were 83 +/- 3.08% and 97 +/- 2.59% respectively. To improve the handling processing and stability of the prepared SLNs, the SLN dispersions were spray dried and its effect on size and reconstitution parameters were evaluated. The spray drying of SLNs did not significantly alter the size of SLNs and they exhibited good redispersibility. Solid state studies such as Infra Red Spectroscopy and Differential Scanning Calorimetry indicated absence of any chemical interaction between Cyclosporine A and the lipids. Scanning Electron Microscopy of optimized formulations showed spherical shape with smooth and non porous surface. In vitro release studies revealed that GMS based SLNs released the drug faster (41.12% in 20 hours) than GPS SLNs (7.958% in 20 hours). Release of Cyclosporine A from GMS SLN followed Higuchi equation better than first order while release from GPS SLN followed first order better than Higuchi model.
Diazepam-loaded solid lipid nanoparticles: design and characterization.
Abdelbary, Ghada; Fahmy, Rania H
2009-01-01
The aim of the present study was to investigate the feasibility of the inclusion of a water-insoluble drug (diazepam, DZ) into solid lipid nanoparticles (SLNs), which offer combined advantages of rapid onset and prolonged release of the drug. This work also describes a new approach to prepare suppositories containing DZ-loaded SLN dispersions, as potential drug carrier for the rectal route. Modified high-shear homogenization and ultrasound techniques were employed to prepare SLNs. The effect of incorporation of different concentrations of Compritol ATO 888 or Imwitor 900K and Poloxamer 188 or Tween 80 was investigated. Results showed that varying the type or concentration of lipid matrix or surfactant had a noticeable influence on the entrapment efficiencies, particle size, and release profiles of prepared SLNs. Differential scanning calorimetry and X-ray diffraction measurements showed that the majority of SLNs possessed less ordered arrangements of crystals than the corresponding bulk lipids, which was favorable for increasing the drug loading capacity. Transmission electron microscopy and laser diffractometry studies revealed that the prepared nanoparticles were round and homogeneous and 60% of the formulations were less than 500 nm. Additionally, SLN formulations showed significant (P < 0.05) prolonged release than DZ solution. The subsequent step encompassed the preparation and evaluation of SLN-based suppositories utilizing SLN formulations that illustrated optimal release profiles. The in vitro release of DZ from the suppositories prepared using DZ-loaded SLN dispersions (equivalent to 2 mg DZ) was significantly (P < 0.05) extended compared to suppositories containing 2 mg DZ free drug.
Uner, M; Wissing, S A; Yener, G; Müller, R H
2005-08-01
The aim of this study was to improve the chemical stability of ascorbyl palmitate (AP) in a colloidal lipid carrier for its topical use. For this purpose, AP-loaded solid lipid nanoparticles (SLN), nanostructured lipid carriers (NLC) and for comparison, a nanoemulsion (NE) were prepared employing the high pressure homogenization technique and stored at room temperature (RT), 4 degrees C and 40 degrees C. During 3 months, physical stability of these formulations compared to placebo formulations which were prepared by the same production method, was studied including recrystallization behaviour of the lipid with differential scanning calorimetry (DSC), particle size distribution and storage stability with photon correlation spectroscopy (PCS) and laser diffractometry (LD). After evaluating data indicating excellent physical stability, AP-loaded SLN, NLC and NE were incorporated into a hydrogel by the same production method as the next step. Degradation of AP by HPLC and physical stability in the same manner were investigated at the same storage temperatures during 3 months. As a result, AP was found most stable in both the NLC and SLN stored at 4 degrees C (p > 0.05) indicating the importance of storage temperature. Nondegraded AP content in NLC, SLN and NE was found to be 71.1% +/- 1.4, 67.6% +/- 2.9 and 55.2% +/- 0.3 after 3 months, respectively. Highest degradation was observed with NE at all the storage temperatures indicating even importance of the carrier structure.
Lymphatic drainage in renal cell carcinoma: back to the basics.
Karmali, Riaz J; Suami, Hiroo; Wood, Christopher G; Karam, Jose A
2014-12-01
Lymphatic drainage in renal cell carcinoma (RCC) is unpredictable, however, basic patterns can be observed in cadaveric and sentinel lymph node mapping studies in patients with RCC. The existence of peripheral lymphovenous communications at the level of the renal vein has been shown in mammals but remains unknown in humans. The sentinel lymph node biopsy technique can be safely applied to map lymphatic drainage patterns in patients with RCC. Further standardisation of sentinel node biopsy techniques is required to improve the clinical significance of mapping studies. Understanding lymphatic drainage in RCC may lead to an evidence-based consensus on the surgical management of retroperitoneal lymph nodes. © 2014 The Authors. BJU International © 2014 BJU International.
Gokce, Evren H; Korkmaz, Emrah; Dellera, Eleonora; Sandri, Giuseppina; Bonferoni, M Cristina; Ozer, Ozgen
2012-01-01
Background Excessive generation of radical oxygen species (ROS) is a contributor to skin pathologies. Resveratrol (RSV) is a potent antioxidant. Solid lipid nanoparticles (SLN) and nanostructured lipid carriers (NLC) can ensure close contact and increase the amount of drug absorbed into the skin. In this study, RSV was loaded into SLN and NLC for dermal applications. Methods Nanoparticles were prepared by high shear homogenization using Compritol 888ATO, Myglyol, Poloxamer188, and Tween80. Particle size (PS), polydispersity index (PI), zeta potential (ZP), drug entrapment efficiency (EE), and production yield were determined. Differential scanning calorimetry (DSC) analysis and morphological transmission electron microscopy (TEM) examination were conducted. RSV concentration was optimized with cytotoxicity studies, and net intracellular accumulation of ROS was monitored with cytofluorimetry. The amount of RSV was determined from different layers of rat abdominal skin. Results PS of uniform RSV-SLN and RSV-NLC were determined as 287.2 nm ± 5.1 and 110.5 nm ± 1.3, respectively. ZP was −15.3 mV ± 0.4 and −13.8 mV ± 0.1 in the same order. The drug EE was 18% higher in NLC systems. TEM studies showed that the drug in the shell model was relevant for SLN, and that the melting point of the lipid in NLC was slightly lower. Concentrations below 50 μM were determined as suitable RSV concentrations for both SLN and NLC in cell culture studies. RSV-NLC showed less fluorescence, indicating less ROS production in cytofluorometric studies. Ex vivo skin studies revealed that NLC are more efficient in carrying RSV to the epidermis. Conclusion This study suggests that both of the lipid nanoparticles had antioxidant properties at a concentration of 50 μM. When the two systems were compared, NLC penetrated deeper into the skin. RSV-loaded NLC with smaller PS and higher drug loading appears to be superior to SLN for dermal applications. PMID:22605933
Chabli, A; Guitton, D; Fortin, S; Molotchnikoff, S
2000-03-01
The present study examined, in the superior colliculus (SC) of anaesthetised cats, the functional connectivity between superficial-layer neurones (SLNs) and tectoreticular neurones (TRNs: collicular output cells). TRNs were antidromically identified by electrical stimulation of the predorsal bundle. The auto- and cross-correlation histograms of visual responses of both types of neurones were recorded and analysed. A delayed, sharp peak in cross-correlograms allowed us to verify whether SLN and TRN cells were coupled; in addition, oscillatory activities were compared to verify if rhythmic responses of SLN sites were transmitted to TRN sites. We found that oscillatory activity was rarely observed in spontaneous activity of superficial (1/74) and TRN sites (1/48). Moving light bars induced oscillation in 31% (23/74) of the superficial-layer and in 23% (11/48) of the TRN sites. The strength of the rhythmic responses was determined by specific ranges of stimulus velocity in 83% (19/23) and 64% (7/11) of oscillating SLN and TRN sites, respectively. Frequencies of oscillations ranged between 5 and 125 Hz and were confined, for 53% of the cells, to the 5-20 Hz band. Thus, the band-width of frequencies of the stimulus-related oscillations in the superior colliculus was broader than the gamma range. Analysis of cross-correlation histograms revealed a significant predominant peak with a mean delay of 2.7+/-0.9 ms in 46% (17/37) of SLN-TRN pairs. Most correlated SLN-TRN pairs (88%: 15/17) had superimposed receptive fields, suggesting they were functionally interconnected. However, individual oscillatory frequencies of correlated and oscillatory SLN and TRN cells were never the same (0/8). Together, these results suggest that the neurones in collicular superficial layer contact TRNs and, consequently, support the idea that the superficial layers contribute to collicular outputs producing eye- and head-orienting movements.
Xu, Shuhang; Feng, Lingling; Chen, Yongming; Sun, Ying; Lu, Yao; Huang, Shaomin; Fu, Yang; Zheng, Rongqin; Zhang, Yujing; Zhang, Rong
2017-06-20
In order to refine the location and metastasis-risk density of 16 lymph node stations of gastric cancer for neoadjuvant radiotherapy, we retrospectively reviewed the initial images and pathological reports of 255 gastric cancer patients with lymphatic metastasis. Metastatic lymph nodes identified in the initial computed tomography images were investigated by two radiologists with gastrointestinal specialty. A circle with a diameter of 5 mm was used to identify the central position of each metastatic lymph node, defined as the LNc (the central position of the lymph node). The LNc was drawn at the equivalent location on the reference images of a standard patient based on the relative distances to the same reference vessels and the gastric wall using a Monaco® version 5.0 workstation. The image manipulation software Medi-capture was programmed for image analysis to produce a contour and density atlas of 16 lymph node stations. Based on a total of 2846 LNcs contoured (31-599 per lymph node station), we created a density distribution map of 16 lymph node drainage stations of the stomach on computed tomography images, showing the detailed radiographic delineation of each lymph node station as well as high-risk areas for lymph node metastasis. Our mapping can serve as a template for the delineation of gastric lymph node stations when defining clinical target volume in pre-operative radiotherapy for gastric cancer.
Characterization of ergocalciferol loaded solid lipid nanoparticles.
Patel, Mandar R; San Martin-Gonzalez, M Fernanda
2012-01-01
The use of solid lipid nanoparticles (SLNs) is a technique that has been widely used in the pharmaceutical industry for the last 2 decades and has become of increasing interest to food scientists due to its potential for encapsulation and controlled release. Ergocalciferol (vitamin D₂) is a bioactive compound whose deficiency may lead to rickets in children and osteomalacia in adults. In this study, ergocalciferol was encapsulated in tripalmitin SLNs stabilized by polysorbate 20 (Tween 20). SLN dispersions (5% w/w) were prepared by hot homogenization technique using a nozzle-type high-pressure homogenizer. Ergocalciferol at 0%, 5%, 10%, 15%, and 20% (w/w of lipid) was dissolved in the molten lipid at 80 °C, mixed with a 5% (w/w) aqueous solution of polysorbate 20 and homogenized at 138 MPa at 80 °C. Particle size, thermal properties, and microstructure were evaluated by dynamic light scattering (DLS), differential scanning calorimetry (DSC), and transmission electron microscopy (TEM) respectively. As the proportion of ergocalciferol in the SLN increased from 0% to 20%, the Z-average values of the particles gradually decreased (P≤ 0.05) from approximately 120 nm to approximately 65 nm. DSC analysis of freeze dried SLN samples showed gradual decrease in enthalpies of fusion and crystallization for stable β-subcell whereas for SLN dispersions, the enthalpy of fusion of unstable α-subcell crystal increased with increased ergocalciferol loading. The TEM images of the ergocalciferol loaded SLN samples showed the presence of spherical as well as rod-shaped nanoparticles. It was also observed that the turbidity of the SLN dispersions reduced noticeably with increased ergocalciferol loading. This finding could be useful in terms of fortification of clear juices with ergocalciferol. Solid lipid nanoparticles (SLNs) were used in this study to encapsulate vitamin D₂, a vitamin important for bone health. It was found that as the concentration of vitamin D₂ increased in the lipid phase of SLN dispersion, the clarity of the dispersion increased. Also, with increased vitamin D₂ concentration, the stability of lipid crystal structure was affected in a way that indicates higher capacity of lipid to incorporate the vitamin molecules and hence to protect them better from oxygen and light. This vitamin loaded SLNs may offer alternatives to milk and margarine as a source of vitamin D. © 2011 Institute of Food Technologists®
Din, Fakhar Ud; Mustapha, Omer; Kim, Dong Wuk; Rashid, Rehmana; Park, Jong Hyuck; Choi, Ju Yeon; Ku, Sae Kwang; Yong, Chul Soon; Kim, Jong Oh; Choi, Han-Gon
2015-08-01
The purpose of this study was to develop novel solid lipid nanoparticle (SLN)-loaded dual-reverse thermosensitive hydrogel (DRTH) for rectal administration of flurbiprofen with improved bioavailability and reduced initial burst effect. The flurbiprofen-loaded SLNs were prepared by hot homogenisation technique, after optimising the amounts of lipid mixture (tricaprin and triethanolamine in 8:2 weight ratio), drug and surfactant. The flurbiprofen-loaded thermosensitive SLN composed of drug, lipid mixture and surfactant at a weight ratio of 10/15/1.3 was a solid at room temperature, and changed to liquid form at physiological temperature due to its melting point of about 32°C. This SLN gave the mean particle size of about 190nm and entrapment efficiency of around 90%. The DRTHs were prepared by adding this flurbiprofen-loaded thermosensitive SLN in various poloxamer solutions. Their rheological characterisation, release and stability were investigated while a morphological and pharmacokinetic study was performed after its rectal administration to rats compared with the drug and hydrogel. Poloxamer 188 and SLN decreased the gelation temperature and gelation time, but increased the viscosity at 25°C, gel strength and mucoadhesive force of DRTHs. In particular, the DRTH composed of [SLN/P 407/P 188 (10%/15%/25%)] with the gelation temperature of about 35°C existed as liquid at room temperature, but gelled at 30-36°C, leading to opposite reversible property of SLN. Thus, it was easy to administer rectally, and it gelled rapidly inside the body. This DRTH gave a significantly increased dissolution rate of the drug as compared to the flurbiprofen, but significantly retarded as compared to the hydrogel, including the initial dissolution rate. Moreover, this DRTH gave significantly higher plasma concentration and 7.5-fold AUC values compared to the drug, and lower initial plasma concentration and Cmax value compared to the hydrogel due to reduced initial burst effect. No damage in rectal mucosa was observed after the application of DRTH. Thus, this DRTH system with improved bioavailability and reduced initial burst effect would be recommended as an alternative for the flurbiprofen-loaded rectal pharmaceutical products. Copyright © 2015 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Xia, Chunxin
Lymphatic drug transport can confer bioavailability advantage by avoiding the first-pass metabolism normally observed in the portal vein hepatic route. It was reported that long chain lipid-based delivery systems can stimulate the formation of chylomicron and thus promote the lymphatic transport of drugs. In this study, a novel delta-tocopherol (delta-T) loaded Solid Lipid Nanoparticle (SLN) system was developed to investigate its effect on promoting the lymphatic transport of delta-T. The delta-T SLN was prepared with hot melt emulsification method by using glyceryl behenate (compritol RTM888) as the lipid phase and lecithin (PC75) as the emulsifier. Formula configuration, processing condition and loading capacity were carefully optimized. Physicochemical properties (particle size, surface charge, morphology) were also characterized. Moreover, excellent stability of the developed delta-T SLN in the gastrointestinal environment was observed by using an in vitro digestion model. Further investigations of the SLN in stimulating delta-T lymphatic transport were performed on mice without cannulation. Compared with the control group (delta-T corn oil dispersion), much lower delta-T levels in both blood and liver indicated reduced portal vein and hepatic transport of delta-T in the form of SLN. On the other hand, significantly higher concentrations of delta-T were observed in thymus, a major lymphatic tissue, indicating improved lymphatic transport of delta-T with the SLN delivery system. Finally, the far less excreted delta-T level in feces further confirmed improved lymphatic transport and overall bioavailability of delta-T by using SLN system. Nobiletin (NOB), one of most abundant polymethoxyflavones (PMFs) found in Citrus genus, has a low solubility in both water and oil at ambient temperatures. Thus it tends to form crystals when the loading exceeds its saturation level in the carrier system. This character greatly impaired its bioavailability and application. To overcome these problems, an O/W nanoemulsion was developed for NOB delivery with the presence of cremophor EL (a polyethoxylated excipient). The developed formulation can achieve a high NOB loading (0.5 wt%) with significantly reduced crystallinity and excellent physical stability. NOB's bioaccessibility and permeation rate across the enterocytes were demonstrated to be significantly improved by the in vitro digestion model and Caco-2 cell monolayer, respectively. It is thus predictable that NOB's bioavailability can be improved with our developed nanoemulsion formulation.
ERIC Educational Resources Information Center
van Dijk, Rick; Boers, Eveline; Christoffels, Ingrid; Hermans, Daan
2011-01-01
The quality of interpretations produced by sign language interpreters was investigated. Twenty-five experienced interpreters were instructed to interpret narratives from (a) spoken Dutch to Sign Language of the Netherlands (SLN), (b) spoken Dutch to Sign Supported Dutch (SSD), and (c) SLN to spoken Dutch. The quality of the interpreted narratives…
Di Filippo, Franco; Di Filippo, Simona; Ferrari, Anna Maria; Antonetti, Raffaele; Battaglia, Alessandro; Becherini, Francesca; Bernet, Laia; Boldorini, Renzo; Bouteille, Catherine; Buglioni, Simonetta; Burelli, Paolo; Cano, Rafael; Canzonieri, Vincenzo; Chiodera, Pierluigi; Cirilli, Alfredo; Coppola, Luigi; Drago, Stefano; Di Tommaso, Luca; Fenaroli, Privato; Franchini, Roberto; Gianatti, Andrea; Giannarelli, Diana; Giardina, Carmela; Godey, Florence; Grassi, Massimo M; Grassi, Giuseppe B; Laws, Siobhan; Massarut, Samuele; Naccarato, Giuseppe; Natalicchio, Maria Iole; Orefice, Sergio; Palmieri, Fabrizio; Perin, Tiziana; Roncella, Manuela; Roncalli, Massimo G; Rulli, Antonio; Sidoni, Angelo; Tinterri, Corrado; Truglia, Maria C; Sperduti, Isabella
2016-12-08
Tumor-positive sentinel lymph node (SLN) biopsy results in a risk of non sentinel node metastases in micro- and macro-metastases ranging from 20 to 50%, respectively. Therefore, most patients underwent unnecessary axillary lymph node dissections. We have previously developed a mathematical model for predicting patient-specific risk of non sentinel node (NSN) metastases based on 2460 patients. The study reports the results of the validation phase where a total of 1945 patients were enrolled, aimed at identifying a tool that gives the possibility to the surgeon to choose intraoperatively whether to perform or not axillary lymph node dissection (ALND). The following parameters were recorded: Clinical: hospital, age, medical record number; Bio pathological: Tumor (T) size stratified in quartiles, grading (G), histologic type, lymphatic/vascular invasion (LVI), ER-PR status, Ki 67, molecular classification (Luminal A, Luminal B, HER-2 Like, Triple negative); Sentinel and non-sentinel node related: Number of NSNs removed, number of positive NSNs, cytokeratin 19 (CK19) mRNA copy number of positive sentinel nodes stratified in quartiles. A total of 1945 patients were included in the database. All patient data were provided by the authors of this paper. The discrimination of the model quantified with the area under the receiver operating characteristics (ROC) curve (AUC), was 0.65 and 0.71 in the validation and retrospective phase, respectively. The calibration determines the distance between predicted outcome and actual outcome. The mean difference between predicted/observed was 2.3 and 6.3% in the retrospective and in the validation phase, respectively. The two values are quite similar and as a result we can conclude that the nomogram effectiveness was validated. Moreover, the ROC curve identified in the risk category of 31% of positive NSNs, the best compromise between false negative and positive rates i.e. when ALND is unnecessary (<31%) or recommended (>31%). The results of the study confirm that OSNA nomogram may help surgeons make an intraoperative decision on whether to perform ALND or not in case of positive sentinel nodes, and the patient to accept this decision based on a reliable estimation on the true percentage of NSN involvement. The use of this nomogram achieves two main gools: 1) the choice of the right treatment during the operation, 2) to avoid for the patient a second surgery procedure.
Lopez Labrousse, Maite I; Frumovitz, Michael; Guadalupe Patrono, M; Ramirez, Pedro T
2017-09-01
Sentinel lymph node mapping, alone or in combination with pelvic lymphadenectomy, is considered a standard approach in staging of patients with cervical or endometrial cancer [1-3]. The goal of this video is to demonstrate the use of indocyanine green (ICG) and color-segmented fluorescence when performing lymphatic mapping in patients with gynecologic malignancies. Injection of ICG is performed in two cervical sites using 1mL (0.5mL superficial and deep, respectively) at the 3 and 9 o'clock position. Sentinel lymph nodes are identified intraoperatively using the Pinpoint near-infrared imaging system (Novadaq, Ontario, CA). Color-segmented fluorescence is used to image different levels of ICG uptake demonstrating higher levels of perfusion. A color key on the side of the monitor shows the colors that coordinate with different levels of ICG uptake. Color-segmented fluorescence may help surgeons identify true sentinel nodes from fatty tissue that, although absorbing fluorescent dye, does not contain true nodal tissue. It is not intended to differentiate the primary sentinel node from secondary sentinel nodes. The key ranges from low levels of ICG uptake (gray) to the highest rate of ICG uptake (red). Bilateral sentinel lymph nodes are identified along the external iliac vessels using both standard and color-segmented fluorescence. No evidence of disease was noted after ultra-staging was performed in each of the sentinel nodes. Use of ICG in sentinel lymph node mapping allows for high bilateral detection rates. Color-segmented fluorescence may increase accuracy of sentinel lymph node identification over standard fluorescent imaging. The following are the supplementary data related to this article. Copyright © 2017 Elsevier Inc. All rights reserved.
Fluorescence-guided mapping of sentinel lymph nodes in gynecological malignancies
NASA Astrophysics Data System (ADS)
Hirsch, Ole; Szyc, Łukasz; Muallem, Mustafa Zelal; Ignat, Iulia; Chekerov, Radoslav; Macdonald, Rainer; Sehouli, Jalid; Braicu, Ioana; Grosenick, Dirk
2017-07-01
We have successfully applied a custom-made handheld fluorescence camera for intraoperative fluorescence detection of indocyanine green in a feasibility study on sentinel lymph node mapping in patients with vulvar, cervical, endometrial and ovarian cancer.
Multimodal US-gamma imaging using collaborative robotics for cancer staging biopsies.
Esposito, Marco; Busam, Benjamin; Hennersperger, Christoph; Rackerseder, Julia; Navab, Nassir; Frisch, Benjamin
2016-09-01
The staging of female breast cancer requires detailed information about the level of cancer spread through the lymphatic system. Common practice to obtain this information for patients with early-stage cancer is sentinel lymph node (SLN) biopsy, where LNs are radioactively identified for surgical removal and subsequent histological analysis. Punch needle biopsy is a less invasive approach but suffers from the lack of combined anatomical and nuclear information. We present and evaluate a system that introduces live collaborative robotic 2D gamma imaging in addition to live 2D ultrasound to identify SLNs in the surrounding anatomy. The system consists of a robotic arm equipped with both a gamma camera and a stereoscopic tracking system that monitors the position of an ultrasound probe operated by the physician. The arm cooperatively places the gamma camera parallel to the ultrasound imaging plane to provide live multimodal visualization and guidance. We validate the system by evaluating the target registration errors between fused nuclear and US image data in a phantom consisting of two spheres, one of which is filled with radioactivity. Medical experts perform punch biopsies on agar-gelatine phantoms with complex configurations of hot and cold lesions to provide a qualitative and quantitative evaluation of the system. The average point registration error for the overlay is [Formula: see text] mm. The time of the entire procedure was reduced by 36 %, with 80v of the biopsies being successful. The users' feedback was very positive, and the system was deemed to be very intuitive, with handling similar to classic US-guided needle biopsy. We present and evaluate the first medical collaborative robotic imaging system. Feedback from potential users for SLN punch needle biopsy is encouraging. Ongoing work investigates the clinical feasibility with more complex and realistic phantoms.
Revealing Fermi arcs and Weyl nodes in MoTe2 by quasiparticle interference mapping
NASA Astrophysics Data System (ADS)
Deng, Peng; Xu, Zhilin; Deng, Ke; Zhang, Kenan; Wu, Yang; Zhang, Haijun; Zhou, Shuyun; Chen, Xi
2017-06-01
A Weyl semimetal exhibits unique properties with Weyl nodes in the bulk and Fermi arcs on the surface. Recently, MoTe2 was found to be a type-II Weyl semimetal, providing a platform for realizing these Weyl physics. Here, we report visualization of topological surface states on the surface of MoTe2 using a scanning tunneling microscope. Scattering between topological states forms quasiparticle interference (QPI) patterns in the Fourier transform of conductance maps. The complete existence of topological surface states in energy momentum space is revealed by d I /d V mapping. By comparing QPI results with a first-principles calculation, we further unveil the locations of Weyl nodes in the surface Brillouin zone. Our work provides spectroscopic information in the unoccupied states, especially those around the Weyl nodes energy, demonstrating the node-arc correlation in Weyl semimetals.
ERIC Educational Resources Information Center
Adesope, Olusola O.; Cavagnetto, Andy; Hunsu, Nathaniel J.; Anguiano, Carlos; Lloyd, Joshua
2017-01-01
This study used a between-subjects experimental design to examine the effects of three different computer-based instructional strategies (concept map, refutation text, and expository scientific text) on science learning. Concept maps are node-link diagrams that show concepts as nodes and relationships among the concepts as labeled links.…
Mehrabibahar, M; Azizi, S; Jangjoo, A; Saremi, E; Kakhki, V R Dabbagh; Sadeghi, R; Chicken, D W; Keshtgar, M
2014-01-01
We evaluated the concordance between peri-areolar blue dye and peri-incisional radiotracer injections for axillary sentinel node mapping of patients with the history of previous breast lesion excisional biopsy. 80 patients with the history of previous excisional biopsy of the breast lesions were included. All patients received two injections of 99mTc-antimony sulfide colloid in both ends of incision line in an intradermal fashion. 2 mL patient blue V dye was injection to all patients in the peri-areolar area of the index quadrant after induction of anesthesia. All blue or hot nodes were harvested as sentinel lymph nodes. At least one sentinel node could be detected during surgery in 79 patients. In total 94 sentinel nodes were detected. All detected sentinel nodes were hot. In three patients sentinel nodes were detected by gamma probe but not blue dye. The tumor location in all of these patients was in the upper lateral quadrant and the incision line was extended into the axillary tail of the breast in all of them. 91 out of 94 sentinel nodes were stained blue, which amounts to 95.8% concordance between blue dye and radiotracer on a per node analysis. Single peri-areolar injection in the index quadrant would suffice for sentinel node mapping of patients with history of excisional biopsy. Care should be taken in patients with large excisional biopsy in the extreme proximity to axilla.
Campbell-Malone, Regina; Holman, Shaina D.; Lukasik, Stacey L.; Fukuhara, Takako; Gierbolini-Norat, Estela M.; Thexton, Allan J.; German, Rebecca Z.
2013-01-01
We tested two hypotheses relating to the sensory deficit that follows a unilateral superior laryngeal nerve (SLN) lesion in an infant animal model. We hypothesized that it would result in (1) a higher incidence of aspiration and (2) temporal changes in sucking and swallowing. We ligated the right-side SLN in six 2–3-week-old female pigs. Using videofluoroscopy, we recorded swallows in the same pre- and post-lesion infant pigs. We analyzed the incidence of aspiration and the duration and latency of suck and swallow cycles. After unilateral SLN lesioning, the incidence of silent aspiration during swallowing increased from 0.7 to 41.5 %. The durations of the suck containing the swallow, the suck immediately following the swallow, and the swallow itself were significantly longer in the post-lesion swallows, although the suck prior to the swallow was not different. The interval between the start of the suck containing a swallow and the subsequent epiglottal movement was longer in the post-lesion swallows. The number of sucks between swallows was significantly greater in post-lesion swallows compared to pre-lesion swallows. Unilateral SLN lesion increased the incidence of aspiration and changed the temporal relationships between sucking and swallowing. The longer transit time and the temporal coordinative dysfunction between suck and swallow cycles may contribute to aspiration. These results suggest that swallow dysfunction and silent aspiration are common and potentially overlooked sequelae of unilateral SLN injury. This validated animal model of aspiration has the potential for further dysphagia studies. PMID:23417250
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, Jiamin; Hoffman, Joanne; Zhao, Jocelyn
2016-07-15
Purpose: To develop an automated system for mediastinal lymph node detection and station mapping for chest CT. Methods: The contextual organs, trachea, lungs, and spine are first automatically identified to locate the region of interest (ROI) (mediastinum). The authors employ shape features derived from Hessian analysis, local object scale, and circular transformation that are computed per voxel in the ROI. Eight more anatomical structures are simultaneously segmented by multiatlas label fusion. Spatial priors are defined as the relative multidimensional distance vectors corresponding to each structure. Intensity, shape, and spatial prior features are integrated and parsed by a random forest classifiermore » for lymph node detection. The detected candidates are then segmented by the following curve evolution process. Texture features are computed on the segmented lymph nodes and a support vector machine committee is used for final classification. For lymph node station labeling, based on the segmentation results of the above anatomical structures, the textual definitions of mediastinal lymph node map according to the International Association for the Study of Lung Cancer are converted into patient-specific color-coded CT image, where the lymph node station can be automatically assigned for each detected node. Results: The chest CT volumes from 70 patients with 316 enlarged mediastinal lymph nodes are used for validation. For lymph node detection, their system achieves 88% sensitivity at eight false positives per patient. For lymph node station labeling, 84.5% of lymph nodes are correctly assigned to their stations. Conclusions: Multiple-channel shape, intensity, and spatial prior features aggregated by a random forest classifier improve mediastinal lymph node detection on chest CT. Using the location information of segmented anatomic structures from the multiatlas formulation enables accurate identification of lymph node stations.« less
Stoffels, I; Dissemond, J; Schulz, A; Hillen, U; Schadendorf, D; Klode, J
2012-02-01
Complete lymph node dissection (CLND) in melanoma patients with a positive sentinel lymph node (SLN) is currently being debated, as it is a cost-intensive surgical intervention with potentially high morbidity. This clinical study seeks to clarify the effectiveness, reliability and cost-effectiveness of CLND performed under tumescent local anaesthesia (TLA) compared with procedures under general anaesthesia (GA). We retrospectively analysed the data from 60 patients with primary malignant melanoma American Joint Committee on Cancer stage III who underwent CLND. Altogether 26 (43.3%) patients underwent CLND under TLA and 34 (56.7%) patients underwent CLND under GA. Fifteen of 43 (34.9%) patients had a complication, such as development of seromas and/or wound infections. The rate of complications was 25.0% (3/12) in the axilla subgroup and 28.6% (4/14) in the groin subgroup of the TLA group. In the GA group, the complication rate was 31.3% (5/16) in the axilla subgroup and 44.4% (8/18) in the groin subgroup. The costs for CLND were significantly less for the CLND in a procedure room performed under TLA (mean €67.26) compared with CLND in an operating room under GA (mean €676.20, P < 0.0001). In conclusion, this study confirms that TLA is an excellent, safe, effective and cost-efficient alternative to GA for CLND in melanoma patients. © 2011 The Authors. Journal of the European Academy of Dermatology and Venereology © 2011 European Academy of Dermatology and Venereology.
A Horizontal Tilt Correction Method for Ship License Numbers Recognition
NASA Astrophysics Data System (ADS)
Liu, Baolong; Zhang, Sanyuan; Hong, Zhenjie; Ye, Xiuzi
2018-02-01
An automatic ship license numbers (SLNs) recognition system plays a significant role in intelligent waterway transportation systems since it can be used to identify ships by recognizing the characters in SLNs. Tilt occurs frequently in many SLNs because the monitors and the ships usually have great vertical or horizontal angles, which decreases the accuracy and robustness of a SLNs recognition system significantly. In this paper, we present a horizontal tilt correction method for SLNs. For an input tilt SLN image, the proposed method accomplishes the correction task through three main steps. First, a MSER-based characters’ center-points computation algorithm is designed to compute the accurate center-points of the characters contained in the input SLN image. Second, a L 1- L 2 distance-based straight line is fitted to the computed center-points using M-estimator algorithm. The tilt angle is estimated at this stage. Finally, based on the computed tilt angle, an affine transformation rotation is conducted to rotate and to correct the input SLN horizontally. At last, the proposed method is tested on 200 tilt SLN images, the proposed method is proved to be effective with a tilt correction rate of 80.5%.
Wang, S L; Xie, S Y; Zhu, L Y; Wang, F H; Zhou, W Z
2009-12-01
Poly (lactic-co-glycolic acid) (PLGA) was used as a co-emulsifier in the preparation of insulin-loaded solid lipid nanoparticles (SLN) with hydrogenated castor oil as lipid matrix and lecithin as surfactant by double-emulsion technique. The effects of PLGA on the preparation and hypoglycaemic activity of insulin-loaded SLN were studied. The results showed that with the supplement of PLGA, the encapsulation efficiency and loading capacity were increased significantly from 79.08 +/- 1.62 to 85.57 +/- 3.21% and 1.58 +/- 0.03 to 1.71 +/- 0.06%, whereas the surface charge and particle size were changed insignificantly from -25.87 +/- 2.65 to -22.67 +/- 1.19 mv and 431.0 +/- 16.1 to 397.0 +/- 68.0 nm, respectively. In vivo studies demonstrated that PLGA increased the sustained hypoglycaemic activity from 12 to 36 h and 24 to 120 h in normal and steptozotocin-induced diabetic mice after a single intramuscular injection of the insulin-loaded SLN. These results demonstrated that PLGA could enhance the entrapment of insulin in the nanoparticles, and more importantly, prolong the time of hypoglycaemic activity of the insulin-loaded SLN.
Synthesis of Trypsin-Resistant Variants of the Listeria-Active Bacteriocin Salivaricin P▿
O'Shea, Eileen F.; O'Connor, Paula M.; Cotter, Paul D.; Ross, R. Paul; Hill, Colin
2010-01-01
Two-component salivaricin P-like bacteriocins have demonstrated potential as antimicrobials capable of controlling infections in the gastrointestinal tract (GIT). The anti-Listeria activity of salivaricin P is optimal when the individual peptides Sln1 and Sln2 are added in succession at a 1:1 ratio. However, as degradation by digestive proteases may compromise the functionality of these peptides within the GIT, we investigated the potential to create salivaricin variants with enhanced resistance to the intestinal protease trypsin. A total of 11 variants of the salivaricin P components, in which conservative modifications at the trypsin-specific cleavage sites were explored in order to protect the peptides from trypsin degradation while maintaining their potent antimicrobial activity, were generated. Analysis of these variants revealed that eight were resistant to trypsin digestion while retaining antimicrobial activity. Combining the complementary trypsin-resistant variants Sln1-5 and Sln2-3 resulted in a MIC50 of 300 nM against Listeria monocytogenes, a 3.75-fold reduction in activity compared to the level for wild-type salivaricin P. This study demonstrates the potential of engineering bacteriocin variants which are resistant to specific protease action but which retain significant antimicrobial activity. PMID:20581174
2013-06-01
08-1-0358 TITLE: Multiadaptive Plan (MAP) IMRT to Accommodate Independent Movement of the Prostate and Pelvic Lymph Nodes PRINCIPAL...AND SUBTITLE Multi-Adaptive Plan (MAP) IMRT to Accommodate Independent 5a. CONTRACT NUMBER W81XWH-08-1-0358 Movement of the Prostate and...multi-adaptive plan (MAP) IMRT to accommodate independent movement of the two targeted tumor volumes. In this project, we evaluated two adaptive
ERIC Educational Resources Information Center
van Beijsterveldt, Liesbeth Maria; van Hell, Janet
2010-01-01
We report an analysis of lexical noun phrases (NPs) in narrative and expository texts written by Dutch deaf individuals from a bimodal bilingual perspective. Texts written by Dutch deaf children and adults who are either proficient in Sign Language of the Netherlands (SLN) or low-proficient in SLN were compared on structures that either overlap in…
Heptapeptide-loaded solid lipid nanoparticles for cosmetic anti-aging applications.
Suter, Franz; Schmid, Daniel; Wandrey, Franziska; Zülli, Fred
2016-11-01
The cosmetic industry requires more and more expensive actives and ingredients such as retinol, coenzyme Q10, proteins, peptides and biotechnologically produced molecules. In this study, we demonstrate the development of a cost effective formulation of a nanostructured lipid carrier (NLC) or solid lipid nanoparticles (SLN) improving peptide delivery into skin. NLC or SLN are very suitable vehicles for the delivery of active ingredients into skin. The SLN, produced by using hot high pressure homogenization method combine advantages such as physical stability, protection of incorporated labile actives and controlled release. By the used method we dispersed the amorphous heptapeptide DEETGEF in shea butter and homogenized this pre-dispersion at 60°C together with the water phase using a Microfluidizer at 1000bar. The analysis of the obtained SLN-P7 showed a particle size of 173nm, incorporated peptide of 0.014%, entrapment efficiency of 90.8%, melting peak (DSC) of the core lipid of 27°C and a zeta potential of -54mV. By an ex vivo study with skin explants we could stimulate NQO1 (NAD(P)H quinone oxidoreductase), HMOX1 (Heme oxygenase-1) and PRDX1 (Peroxiredoxin-1) genes all of which are cell protecting enzymes. In a multicellular protection against UV induced stress study with skin explants we detected the formation of sun burn cells and the number and morphology of Langerhans cells. The application of our SLN-P7 formulation on skin explants led to a significant and dose dependent protection against UV irradiation. In the clinical suction blister study, irradiation with UVA light for two hours after final product application led to a statistically significant increase of the 8-OhdG (8-hydroxy-2'-deoxyguanosine) concentration in the human epidermis. The skin treated with our verum formulation showed a statistically significant 20% decrease in DNA damage compared to placebo. In conclusion, it was demonstrated that SLN technology enabled peptide delivery into skin allowing it to perform protective functions. Copyright © 2016 Elsevier B.V. All rights reserved.
Network geometry inference using common neighbors
NASA Astrophysics Data System (ADS)
Papadopoulos, Fragkiskos; Aldecoa, Rodrigo; Krioukov, Dmitri
2015-08-01
We introduce and explore a method for inferring hidden geometric coordinates of nodes in complex networks based on the number of common neighbors between the nodes. We compare this approach to the HyperMap method, which is based only on the connections (and disconnections) between the nodes, i.e., on the links that the nodes have (or do not have). We find that for high degree nodes, the common-neighbors approach yields a more accurate inference than the link-based method, unless heuristic periodic adjustments (or "correction steps") are used in the latter. The common-neighbors approach is computationally intensive, requiring O (t4) running time to map a network of t nodes, versus O (t3) in the link-based method. But we also develop a hybrid method with O (t3) running time, which combines the common-neighbors and link-based approaches, and we explore a heuristic that reduces its running time further to O (t2) , without significant reduction in the mapping accuracy. We apply this method to the autonomous systems (ASs) Internet, and we reveal how soft communities of ASs evolve over time in the similarity space. We further demonstrate the method's predictive power by forecasting future links between ASs. Taken altogether, our results advance our understanding of how to efficiently and accurately map real networks to their latent geometric spaces, which is an important necessary step toward understanding the laws that govern the dynamics of nodes in these spaces, and the fine-grained dynamics of network connections.
Majeski, Stephanie A; Steffey, Michele A; Fuller, Mark; Hunt, Geraldine B; Mayhew, Philipp D; Pollard, Rachel E
2017-05-01
Sentinel lymph node mapping can help to direct surgical oncologic staging and metastatic disease detection in patients with complex lymphatic pathways. We hypothesized that indirect computed tomographic lymphography (ICTL) with a water-soluble iodinated contrast agent would successfully map lymphatic pathways of the iliosacral lymphatic center in dogs with anal sac gland carcinoma, providing a potential preoperative method for iliosacral sentinel lymph node identification in dogs. Thirteen adult dogs diagnosed with anal sac gland carcinoma were enrolled in this prospective, pilot study, and ICTL was performed via peritumoral contrast injection with serial caudal abdominal computed tomography scans for iliosacral sentinel lymph node identification. Technical and descriptive details for ICTL were recorded, including patient positioning, total contrast injection volume, timing of contrast visualization, and sentinel lymph nodes and lymphatic pathways identified. Indirect CT lymphography identified lymphatic pathways and sentinel lymph nodes in 12/13 cases (92%). Identified sentinel lymph nodes were ipsilateral to the anal sac gland carcinoma in 8/12 and contralateral to the anal sac gland carcinoma in 4/12 cases. Sacral, internal iliac, and medial iliac lymph nodes were identified as sentinel lymph nodes, and patterns were widely variable. Patient positioning and timing of imaging may impact successful sentinel lymph node identification. Positioning in supported sternal recumbency is recommended. Results indicate that ICTL may be a feasible technique for sentinel lymph node identification in dogs with anal sac gland carcinoma and offer preliminary data to drive further investigation of iliosacral lymphatic metastatic patterns using ICTL and sentinel lymph node biopsy. © 2017 American College of Veterinary Radiology.
Yucel, Umut; Elias, Ryan J; Coupland, John N
2013-03-15
The distribution and reactivity of the lipophilic spin probe 4-phenyl-2,2,5,5-tetramethyl-3-imidazoline-1-oxyl nitroxide (PTMIO) in tetradecane (C14)- and eicosane (C20)-in-water emulsions and solid lipid nanoparticles (SLN) respectively, were investigated by electron paramagnetic resonance (EPR) spectroscopy. The lipid phase (10 wt% C14 or C20) was emulsified into either caseinate solutions (1 wt%) or lecithin+bile salt dispersions (2.4 wt%+0.6 wt%) at 70-75 °C. In C14 emulsions stabilized with lecithin+bile salt, three populations of PTMIO were observed: a population in the lipid phase (~60%, a(N)~13.9 G), an aqueous phase population (~20%, a(N)~15.4 G) with high mobility, and an immobilized surface layer population (~20%, a(N)~14.2 G) with low mobility. However, in C14 emulsions stabilized by caseinate, only two distinct populations of PTMIO were seen: a lipid phase population (~70%, a(N)~13.8 G) and an aqueous phase population (~30%, a(N)~15.5 G) with high mobility. In C20 SLN stabilized with either lecithin+bile salt or caseinate, PTMIO was excluded from the lipid phase. In lecithin+bile salt-stabilized C20 SLN, the majority of the probe (~77%) was in the interfacial layer. For both surfactant systems the rate of PTMIO reduction by aqueous iron/ascorbate was greater for C20 SLN than C14 emulsions. Lecithin affects the properties of emulsions and SLN as delivery systems by providing a distinct environment for small molecules. Copyright © 2013 Elsevier Inc. All rights reserved.
Ling, Z; Yonghong, L; Changqing, S; Junfeng, L; Li, Z; Chunyu, J; Xianqiang, L
2017-06-01
To effectively control bovine mastitis, tilmicosin (TIL)- and florfenicol (FF)-loaded solid lipid nanoparticles (SLN) with hydrogenated castor oil (HCO) were prepared by a hot homogenization and ultrasonication method. In vitro antibacterial activity, properties, and pharmacokinetics of the TIL-FF-SLN were studied. The results demonstrated that TIL and FF had a synergistic or additive antibacterial activity against Streptococcus dysgalactiae, Streptococcus uberis, and Streptococcus agalactiae. The size, polydispersity index, and zeta potential of nanoparticles were 289.1 ± 13.7 nm, 0.31 ± 0.05, and -26.7 ± 1.3 mV, respectively. The encapsulation efficiencies for TIL and FF were 62.3 ± 5.9% and 85.1 ± 5.2%, and the loading capacities for TIL and FF were 8.2 ± 0.6% and 3.3 ± 0.2%, respectively. The TIL-FF-SLN showed no irritation in the injection site and sustained release in vitro. After medication, TIL and FF could maintain about 0.1 μg/mL for 122 and 6 h. Compared to the control solution, the SLN increased the area under the concentration-time curve (AUC 0-t ), elimination half-life (T ½ke ), and mean residence time (MRT) of TIL by 33.09-, 23.29-, and 37.53-fold, and 1.69-, 5.00-, and 3.83-fold for FF, respectively. These results of this exploratory study suggest that the HCO-SLN could be a useful system for the delivery of TIL and FF for bovine mastitis therapy. © 2016 John Wiley & Sons Ltd.
Nakasato, Daniele Y; Pereira, Anderson E S; Oliveira, Jhones L; Oliveira, Halley C; Fraceto, Leonardo F
2017-08-01
Although the potential toxicity of many metallic and carbon nanoparticles to plants has been reported, few studies have evaluated the phytotoxic effects of polymeric and solid lipid nanoparticles. The present work described the preparation and characterization of chitosan/tripolyphosphate (CS/TPP) nanoparticles and solid lipid nanoparticles (SLN) and evaluated the effects of different concentrations of these nanoparticles on germination of Zea mays, Brassica rapa, and Pisum sativum. CS/TPP nanoparticles presented an average size of 233.6±12.1nm, polydispersity index (PDI) of 0.30±0.02, and zeta potential of +21.4±1.7mV. SLN showed an average size of 323.25±41.4nm, PDI of 0.23±0.103, and zeta potential of -13.25±3.2mV. Nanotracking analysis enabled determination of concentrations of 1.33×10 10 (CS/TPP) and 3.64×10 12 (SLN) nanoparticles per mL. At high concentrations, CS/TPP nanoparticles caused complete inhibition of germination, and thus negatively affected the initial growth of all tested species. Differently, SLN presented no phytotoxic effects. The different size and composition and the opposite charges of SLN and CS/TPP nanoparticles could be associated with the differential phytotoxicity of these nanomaterials. The present study reports the phytotoxic potential of polymeric CS/TPP nanoparticles towards plants, indicating that further investigation is needed on the effects of such formulations intended for future use in agricultural systems, in order to avoid damage to the environment. Copyright © 2017 Elsevier Inc. All rights reserved.
Bal, Naresh C; Singh, Sushant; Reis, Felipe C G; Maurya, Santosh K; Pani, Sunil; Rowland, Leslie A; Periasamy, Muthu
2017-10-06
Thermogenesis is an important homeostatic mechanism essential for survival and normal physiological functions in mammals. Both brown adipose tissue (BAT) ( i.e. uncoupling protein 1 (UCP1)-based) and skeletal muscle ( i.e. sarcolipin (SLN)-based) thermogenesis processes play important roles in temperature homeostasis, but their relative contributions differ from small to large mammals. In this study, we investigated the functional interplay between skeletal muscle- and BAT-based thermogenesis under mild versus severe cold adaptation by employing UCP1 -/- and SLN -/- mice. Interestingly, adaptation of SLN -/- mice to mild cold conditions (16 °C) significantly increased UCP1 expression, suggesting increased reliance on BAT-based thermogenesis. This was also evident from structural alterations in BAT morphology, including mitochondrial architecture, increased expression of electron transport chain proteins, and depletion of fat droplets. Similarly, UCP1 -/- mice adapted to mild cold up-regulated muscle-based thermogenesis, indicated by increases in muscle succinate dehydrogenase activity, SLN expression, mitochondrial content, and neovascularization, compared with WT mice. These results further confirm that SLN-based thermogenesis is a key player in muscle non-shivering thermogenesis (NST) and can compensate for loss of BAT activity. We also present evidence that the increased reliance on BAT-based NST depends on increased autonomic input, as indicated by abundant levels of tyrosine hydroxylase and neuropeptide Y. Our findings demonstrate that both BAT and muscle-based NST are equally recruited during mild and severe cold adaptation and that loss of heat production from one thermogenic pathway leads to increased recruitment of the other, indicating a functional interplay between these two thermogenic processes. © 2017 by The American Society for Biochemistry and Molecular Biology, Inc.
Martinelli, Fabio; Ditto, Antonino; Signorelli, Mauro; Bogani, Giorgio; Chiappa, Valentina; Lorusso, Domenica; Scaffa, Cono; Recalcati, Dario; Perotto, Stefania; Haeusler, Edward; Raspagliesi, Francesco
2017-09-01
To analyze detection-rate(DR) and diagnostic-accuracy (A) of sentinel-nodes(SLNs) mapping following hysteroscopic-injection of tracer. To compare DR and A between tracers: ICG and Tc99m. Evaluation of endometrial-cancer patients who underwent SLNs mapping after hysteroscopic-peritumoral-injection of tracer±lymphadenectomy. Analysis of DR (overall-bilateral-aortic) and A in the entire cohort and comparison between tracers. 202 procedures were performed from January/2005 to February/2017. Mean age:60years (28-82); mean BMI: 26.8 kg/m 2 (15-47). In 133 cases (65.8%) hysterectomy and mapping procedure were performed laparoscopically. The overall-DR of the technique was 93.2% (179/192) (10 cases were excluded: 9 for technical-equipment failure; 1 for vagal reaction). Bilateral pelvic mapping was found in 59.7% of cases (107/179) and was more frequent in the ICG group (72.8% vs 53.3%; p: 0.012). In 50.8% of cases (91/179) SLNs were mapped both in pelvic and aortic nodes, and in 5 cases (2.8%) only in the aortic area. The mean number of detected SLNs was 3.7 (1-8). 22 patients (12.3%) had nodal involvement: 10-(45.5%)-macrometastases; 5-(22.7%)-micrometastases; 7-(31.8%)-ITCs. In 6 cases (27.3%) only aortic nodes were positive; in 5 cases (22.7%) both pelvic and aortic nodes and in 11 cases (50%) only pelvic nodes were involved. Three false-negative results were found, all in the Tc99m group. All had isolated aortic metastases with negative pelvic nodes. Overall-sensitivity was 86.4% (95%CI: 68.4-100) and overall-negative-predictive-value (NPV) was 96.4% (95%CI 86.7-100). No differences in terms of overall-DR, overall-sensitivity and overall-NPV were found between the two tracers. Hysteroscopic-injection of tracer for SLNs mapping in endometrial cancer is as accurate as cervical injection with a higher DR in the aortic area. ICG improves bilateral-DR. Further investigation is warranted on this topic. Copyright © 2017 Elsevier Inc. All rights reserved.
Di Guilmi, Julian; Darin, Maria Cecilia; Toscano, Maria; Maya, Gustavo
To demonstrate the initial experience in Argentina using the iSpies indocyanine green (ICG) platform in sentinel lymph node mapping in patients with early-stage cervical cancer. Step-by-step demonstration of the technique using a video and pictures (educative video) (Canadian Task Force classification III). Laparoscopic and robotic sentinel lymph node mapping using ICG has been shown to be safe and feasible; however, in developing countries, the opportunities to use fluorescent imaging through a minimally invasive approach are very limited, given the cost restrictions of acquiring the near-infrared technology and the fluorescent dyes. A 47-year-old woman presented with a stage IB1 squamous cervical cancer. Physical examination revealed a 1.5-cm tumor without evidence of parametrial involvement. Magnetic resonance imaging did not show any evidence of metastatic disease. The patient underwent laparoscopic radical hysterectomy with sentinel lymph node mapping. On laparoscopic exposure of the pelvic spaces, a cervical injection of ICG (1 mL superficial and deep) was administered using a spinal needle at the 3 o'clock and 9 o'clock positions. Sentinel lymph node mapping was then performed using the ICG (Pulsion Medical Systems, Feldkirchen, Germany) and an iSpies near-infrared camera (Karl Storz Endoskope, Tuttlingen, Germany). Bilateral sentinel lymph nodes were detected on the left external iliac artery and in the right obturator space. Both were confirmed ex vivo. The total operative time was 170 minutes. No intraoperative or postoperative complications were reported, and the patient was discharged at 48 hours after surgery. Estimated blood loss was minimal. Sentinel lymph node mapping alone is not the standard of care in our institution, and thus bilateral lymphadenectomy was performed. Ultrastaging is routinely performed when a sentinel lymph node is evaluated. Final pathology revealed a tumor confined to the cervix, with tumor-free margins, and a total of 10 lymph nodes that were negative for any evidence of disease. Disadvantages of this technology compared with the Pinpoint ICG system (Novadaq Technologies; Bonita Springs, FL) is the lack of simultaneous white vision and fluorescence ICG detection, and the to manually change normal vision to infrared vision. An advantage of the Storz iSpies system is its availability in our country, considering that the technology developed by Novadaq is not yet approved in Argentina. Although ICG sentinel lymph node mapping is becoming a standard of care [1,2], a lack of ICG dye or laparoscopic near-infrared technologies could be a deterrent to its use in developing countries. A focus on expanding this technology in countries with limited resources would allow patients the opportunity to avoid the morbidity associated with full lymphadenectomy. Copyright © 2017 American Association of Gynecologic Laparoscopists. Published by Elsevier Inc. All rights reserved.
Talluri, Siddhartha Venkata; Kuppusamy, Gowthamarajan; Karri, Veera Venkata Satyanarayana Reddy; Yamjala, Karthik; Wadhwani, Ashish; Madhunapantula, SubbaRao V; Pindiprolu, Saikiran S S
2017-05-01
The current work was carried out by the principles of quality-by-design approach to develop an optimized solid lipid nanoparticles (SLNs) formulation of diallyl disulfide (DADS) through systematic statistical study. And its antitumor activity of DADS was also evaluated on breast cancer cell lines. To understand the effect of formulation variables (critical parameters) on the responses (critical quality attributes) of SLN, a 3-factor, 3-level Box-Behnken design, was explored to predict the responses such as particle size (Y1) and % entrapment efficiency (EE) (Y2) when concentration of surfactant (X1), amount of lipid (X2), and volume of solvent (X3) were selected as independent variables. Particle size analysis revealed that all the batches were within the nanometer range. DADS was released from the SLN much more rapidly at pH 4.5 than at pH 7.4, which is a desirable characteristic for tumor-targeted drug delivery. The cytotoxicity, reactive oxygen species (ROS), determination revealed that the antitumor activity of DADS is enhanced with SLN compared to DADS-free drug, and apoptosis is the mechanism underlying the cytotoxicity. The present study indicated the remarkable potential of DADS-SLN in enhancing the anticancer effect of DADS in breast cancer cells in vitro.
Attama, A A; Reichl, S; Müller-Goymann, C C
2009-08-01
The aim of the study was to formulate and evaluate surface-modified solid lipid nanoparticles sustained delivery system of timolol hydrogen maleate, a prototype ocular drug using a human cornea construct. Surface-modified solid lipid nanoparticles containing timolol with and without phospholipid were formulated by melt emulsification with high-pressure homogenization and characterized by particle size, wide-angle X-ray diffraction, encapsulation efficiency, and in vitro drug release. Drug transport studies through cornea bioengineered from human donor cornea cells were carried out using a modified Franz diffusion cell and drug concentration analyzed by high-performance liquid chromatography. Results show that surface-modified solid lipid nanoparticles possessed very small particles (42.9 +/- 0.3 nm, 47.2 +/- 0.3 nm, 42.7 +/- 0.7 nm, and 37.7 +/- 0.3 nm, respectively for SM-SLN 1, SM-SLN 2, SM-SLN 3, and SM-SLN 4) with low polydispersity indices, increased encapsulation efficiency (> 44%), and sustained in vitro release compared with unmodified lipid nanoparticles whose particles were greater than 160 nm. Permeation of timolol hydrogen maleate from the surface-modified lipid nanoparticles across the cornea construct was sustained compared with timolol hydrogen maleate solution in distilled water. Surface-modified solid lipid nanoparticles could provide an efficient way of improving ocular bioavailability of timolol hydrogen maleate.
Sznitowska, Malgorzata; Wolska, Eliza; Baranska, Helena; Cal, Krzysztof; Pietkiewicz, Justyna
2017-01-01
Solid lipid microparticles (SLM) were produced by a two-step process that, firstly, involved the emulsification of the molten lipid phase in a heated aqueous phase and, secondly, the system cooling. Compritol 888 ATO and Precirol ATO 5, including their mixtures with Miglyol 812 or Witepsol H15 were used as lipid components (10-30% w/w). The average size of the SLM prepared with Compritol and Tween 80 as an emulsifier was 3-7μm and the influence of lipid concentration and thermal sterilization was not large. Dispersions of SLM with Precirol (10-20% w/w) gellified upon storage. SLM stabilized with another surfactant, Tego Care 450, were larger in size and measured 40μm on average. The use of the sonication step (5-15min) in hot formulations containing 5% w/w of Compritol resulted in the formation of the solid lipid nanoparticles (SLN) with average size 200-300nm. The smallest SLN size (below 100nm on average) was obtained in SLN that contained Tego Care and an antimicrobial agent Euxyl PE 9010; such combination evoked synergism between the surfactant and Euxyl components. Copyright © 2016 Elsevier B.V. All rights reserved.
Fanfani, Francesco; Monterossi, Giorgia; Ghizzoni, Viola; Rossi, Esther D; Dinoi, Giorgia; Inzani, Frediano; Fagotti, Anna; Gueli Alletti, Salvatore; Scarpellini, Francesca; Nero, Camilla; Santoro, Angela; Scambia, Giovanni; Zannoni, Gian F
2018-01-01
The aim of the current study is to evaluate the detection rate of micro- and macro-metastases of the One-Step Nucleic Acid Amplification (OSNA) compared to frozen section examination and subsequent ultra-staging examination in early stage endometrial cancer (EC). From March 2016 to June 2016, data of 40 consecutive FIGO stage I EC patients were prospectively collected in an electronic database. The sentinel lymph node mapping was performed in all patients. All mapped nodes were removed and processed. Sentinel lymph nodes were sectioned and alternate sections were respectively examined by OSNA and by frozen section analysis. After frozen section, the residual tissue from each block was processed with step-level sections (each step at 200 micron) including H&E and IHC slides. Sentinel lymph nodes mapping was successful in 29 patients (72.5%). In the remaining 11 patients (27.5%), a systematic pelvic lymphadenectomy was performed. OSNA assay sensitivity and specificity were 87.5% and 100% respectively. Positive and negative predictive values were 100% and 99% respectively, with a diagnostic accuracy of 99%. As far as frozen section examination and subsequent ultra-staging analysis was concerned, we reported sensitivity and specificity of 50% and 94.4% respectively; positive and negative predictive values were 14.3% and 99%, respectively, with an accuracy of 93.6%. In one patient, despite negative OSNA and frozen section analysis of the sentinel node, a macro-metastasis in 1 non-sentinel node was found. The combination of OSNA procedure with the sentinel lymph node mapping could represent an efficient intra-operative tool for the selection of early-stage EC patients to be submitted to systematic lymphadenectomy.
Dealing with Liars: Misbehavior Identification via Rényi-Ulam Games
NASA Astrophysics Data System (ADS)
Kozma, William; Lazos, Loukas
We address the problem of identifying misbehaving nodes that refuse to forward packets in wireless multi-hop networks. We map the process of locating the misbehaving nodes to the classic Rényi-Ulam game of 20 questions. Compared to previous methods, our mapping allows the evaluation of node behavior on a per-packet basis, without the need for energy-expensive overhearing techniques or intensive acknowledgment schemes. Furthermore, it copes with colluding adversaries that coordinate their behavioral patterns to avoid identification and frame honest nodes. We show via simulations that our algorithms reduce the communication overhead for identifying misbehaving nodes by at least one order of magnitude compared to other methods, while increasing the identification delay logarithmically with the path size.
Flexible embedding of networks
NASA Astrophysics Data System (ADS)
Fernandez-Gracia, Juan; Buckee, Caroline; Onnela, Jukka-Pekka
We introduce a model for embedding one network into another, focusing on the case where network A is much bigger than network B. Nodes from network A are assigned to the nodes in network B using an algorithm where we control the extent of localization of node placement in network B using a single parameter. Starting from an unassigned node in network A, called the source node, we first map this node to a randomly chosen node in network B, called the target node. We then assign the neighbors of the source node to the neighborhood of the target node using a random walk based approach. To assign each neighbor of the source node to one of the nodes in network B, we perform a random walk starting from the target node with stopping probability α. We repeat this process until all nodes in network A have been mapped to the nodes of network B. The simplicity of the model allows us to calculate key quantities of interest in closed form. By varying the parameter α, we are able to produce embeddings from very local (α = 1) to very global (α --> 0). We show how our calculations fit the simulated results, and we apply the model to study how social networks are embedded in geography and how the neurons of C. Elegans are embedded in the surrounding volume.
Lan, Yuan-Tzu; Huang, Kuo-Hung; Chen, Ping-Hsien; Liu, Chien-An; Lo, Su-Shun; Wu, Chew-Wun; Shyr, Yi-Ming; Fang, Wen-Liang
2017-01-01
Robotic gastrectomy has become increasingly popular in the treatment of gastric cancer, especially in Asian countries. The use of indocyanine green fluorescence has been reported in lymphatic mapping for gastric cancer in laparoscopic gastrectomy; however, there have been few reports regarding the use of indocyanine green in robotic gastrectomy. From January 2011 to March 2016, a total of 79 patients underwent robotic gastrectomy for gastric cancer. Among them, intraoperative subserosal injection (n = 9) or preoperative submucosal injection (n = 5) of indocyanine green with near-infrared imaging was performed in 14 patients, and the other 65 patients underwent robotic gastrectomy without the use of indocyanine green. There was no significant difference in the operative time, total number of retrieved lymph nodes, operative blood loss, and postoperative hospital stay between the patients who underwent robotic gastrectomy with or without indocyanine green fluorescence. For each lymph node station, there was significantly more number of retrieved lymph nodes in the indocyanine green group than in the no-indocyanine green group at the greater curvature side of the low body (#4d) to the infrapyloric region (#6) of the stomach. Five of the 14 patients who received an indocyanine green injection for lymphatic mapping had lymph node metastasis, and metastatic lymph nodes were located in the lymph node stations as detected by indocyanine green fluorescence during surgery. Indocyanine green fluorescence with near-infrared imaging is feasible and is a promising method of lymphatic mapping in robotic gastrectomy for gastric cancer. In future studies, larger patient numbers and long-term follow-up are required.
Vipham, J L; Loneragan, G H; Guillen, L M; Brooks, J C; Johnson, B J; Pond, A; Pond, N; Brashears, M M
2015-12-01
Despite effective food safety interventions within abattoirs, Salmonella enterica remains a common contaminant of raw ground beef. Research has recently implicated peripheral lymph nodes (PLNs) as a potential route by which Salmonella contaminates ground beef. This study examined the efficacy of using Lactobacillus animalis (formerly designated Lactobacillus acidophilus; NP51) and Propionibacterium freudenreichii (NP24), at 10(9) cfu/head/day, as a direct-fed microbial (DFM) in feedlot cattle diets to control Salmonella within PLNs. Two studies were conducted in which cattle were randomly allocated into either control or DFM treatment groups. Diets of treated cattle were supplemented with 10(9) cfu/head/day of the DFM, while control groups received no DFM supplementation. During slaughter at abattoirs, one subiliac lymph node (SLN) per carcass was collected from 627 carcasses from one study and 99 carcasses from the second study. Lymph nodes were cultured to estimate the presence and concentration of Salmonella. In the first study, effects of DFM supplementation varied across slaughter days. On the first and second slaughter days, prevalence was reduced by 50% (P = 0.0072) and 31% (P = 0.0093), respectively. No significant difference was observed on slaughter day three (P = 0.1766). In the second study, Salmonella was 82% less likely (P = 0.008) to be recovered from SLNs of treatment cattle. While a greater relative risk reduction was observed in the latter study, absolute risk reductions were similar across studies. A significant reduction in the concentration of Salmonella in SLNs (P < 0.0001) on a cfu/g and cfu/node basis was also observed in cattle administered NP51 and NP24 in the first study; in the second study, too few quantifiable SLNs were observed to facilitate meaningful comparisons. The results indicate that NP51 and NP24 supplementation may aid in reducing the prevalence and concentration of Salmonella in SLNs and, therefore, serve as an effective control measure to reduce Salmonella in ground beef products. © 2015 Blackwell Verlag GmbH.
Baviskar, D T; Amritkar, A S; Chaudhari, H S; Jain, D K
2012-08-01
In this study, flurbiprofen (FLB) Solid Lipid Nanoparticles (SLN) composed from a mixture of beeswax and carnauba wax, Tween 80 and egg lecithin as emulsifiers have been prepared. FLB was incorporated as model lipophilic drug to assess the influence of matrix composition in the drug release profile. SLN were produced by microemulsion technique. In vitro studies were performed in Phosphate Buffered Saline (PBS). The FLB loaded SLN showed a mean particle size of 75 +/- 4 nm, a polydispersity index approximately 0.2 +/- 0.02 and an entrapment efficiency (EE) of more than 95%. Suspensions were stable, with zeta potential values in the range of -15 to -17 mV. DSC thermograms and UV analysis indicated the stability of nanoparticles with negligible drug leakage. Nanoparticles with higher beeswax content in their core exhibited faster drug release than those containing more carnauba wax.
Tummala, Shashank; Gowthamarajan, K; Satish Kumar, M N; Praveen, T K; Yamjala, Karthik; Tripuraneni, Naga Srinivas; Prakash, Ashwati
2016-12-01
Conventional chemotherapy majorly lacks clinical application attributed to its inspecificity, adverse effects and inability to penetrate into tumor cells. Hence, the aim of the study was to prepare oxaliplatin solid lipid nanoparticles (OP-SLN) by microemulsion method optimizing it by Box-Behnken design and then covalently conjugated to TRAIL (CD-253) monoclonal antibody (TR-OP-SLN) for targeting colorectal cancer cells. The optimized OP-SLN3 has shown an appreciable particle size (121 ± 1.22 nm), entrapment efficiency (78 ± 0.09%) and drug loading (32 ± 1.01%). Fluorescence study and the Bradford assay further confirmed the binding of the protein. A 1.5-fold increase in cytotoxicity of immuno-nanoparticles (4.9 μM) was observed.
Mozzillo, N; Pasquali, S; Santinami, M; Testori, A; Di Marzo, M; Crispo, A; Patuzzo, R; Verrecchia, F; Botti, G; Montella, M; Rossi, C R; Caracò, C
2015-07-01
The optimal extent of the groin lymph node (LN) dissection for melanoma patients with positive sentinel LN biopsy is still debated and no agreement exist on dissection of pelvic LN. This study aimed at investigating predictors of pelvic LN metastasis and prognostic significance of having metastasis in the pelvic LNs. Clinicopathologic data of 740 patients with positive groin sentinel LN who underwent ilioinguinal completion LN dissection at four Italian centre were analysed. Multivariable logistic and Cox regression analysis was used to identify independent predictors of pelvic LN metastasis and to adjust prognostic significance of pelvic LN metastasis. More than a quarter (26%) of patients had positive non-SLNs after inguinal and pelvic lymphadenectomy, which were located in their pelvis in the 12% of cases. Older patients [(OR) 1.69; 95% confidence interval (CI) 1.02-2.78] having thick primary (OR 1.6; 95% CI, 1.01-2.53) and ≥ 2 positive SLNs (OR 2.5; 95% CI, 1.4-4.47) were more likely to harbour pelvic LN metastasis. Interestingly, 4% of all patients (34% of patients with positive pelvic LNs) had pelvic LN metastasis with negative inguinal LNs. Pelvic LN metastasis was independently associated with higher risk of recurrence and lower survival. 5-year disease free and overall survival was 30% and 50%, respectively, for patients with pelvic LN metastasis. Pelvic LNs are frequently positive after ilioinguinal lymphadenectomy and it should be considered for all patients, especially those who are older, have thick primary and ≥ 2 positive SLN. Patients with pelvic LN metastasis have worse prognosis. Copyright © 2015 Elsevier Ltd. All rights reserved.
Lynch, Rod; Pitson, Graham; Ball, David; Claude, Line; Sarrut, David
2013-01-01
To develop a reproducible definition for each mediastinal lymph node station based on the new TNM classification for lung cancer. This paper proposes an atlas using the new international lymph node map used in the seventh edition of the TNM classification for lung cancer. Four radiation oncologists and 1 diagnostic radiologist were involved in the project to put forward a reproducible radiologic description for the lung lymph node stations. The International Association for the Study of Lung Cancer lymph node definitions for stations 1 to 11 have been described and illustrated on axial computed tomographic scan images using a certified radiotherapy planning system. This atlas will assist both diagnostic radiologists and radiation oncologists in accurately defining the lymph node stations on computed tomographic scan in patients diagnosed with lung cancer. Copyright © 2013 American Society for Radiation Oncology. Published by Elsevier Inc. All rights reserved.
Near infrared imaging to identify sentinel lymph nodes in invasive urinary bladder cancer
NASA Astrophysics Data System (ADS)
Knapp, Deborah W.; Adams, Larry G.; Niles, Jacqueline D.; Lucroy, Michael D.; Ramos-Vara, Jose; Bonney, Patty L.; deGortari, Amalia E.; Frangioni, John V.
2006-02-01
Approximately 12,000 people are diagnosed with invasive transitional cell carcinoma of the urinary bladder (InvTCC) each year in the United States. Surgical removal of the bladder (cystectomy) and regional lymph node dissection are considered frontline therapy. Cystectomy causes extensive acute morbidity, and 50% of patients with InvTCC have occult metastases at the time of diagnosis. Better staging procedures for InvTCC are greatly needed. This study was performed to evaluate an intra-operative near infrared fluorescence imaging (NIRF) system (Frangioni laboratory) for identifying sentinel lymph nodes draining InvTCC. NIRF imaging was used to map lymph node drainage from specific quadrants of the urinary bladder in normal dogs and pigs, and to map lymph node drainage from naturally-occurring InvTCC in pet dogs where the disease closely mimics the human condition. Briefly, during surgery NIR fluorophores (human serum albumen-fluorophore complex, or quantum dots) were injected directly into the bladder wall, and fluorescence observed in lymphatics and regional nodes. Conditions studied to optimize the procedure including: type of fluorophore, depth of injection, volume of fluorophore injected, and degree of bladder distention at the time of injection. Optimal imaging occurred with very superficial injection of the fluorophore in the serosal surface of the moderately distended bladder. Considerable variability was noted from dog to dog in the pattern of lymph node drainage. NIR fluorescence was noted in lymph nodes with metastases in dogs with InvTCC. In conclusion, intra-operative NIRF imaging is a promising approach to improve sentinel lymph node mapping in invasive urinary bladder cancer.
NASA Astrophysics Data System (ADS)
Patel, Meghavi
Solid lipid nanoparticles (SLNs) consist of spherical solid lipid particles in the nanometer size range, which are dispersed in water or in an aqueous surfactant solution. SLN technology represents a promising new approach to deliver hydrophilic as well as lipophilic drugs. The commercialization of SLN technology remains limited despite numerous efforts from researchers. The purpose of this research was to advance SLN preparation methodology by investigating the feasibility of preparing glyceryl monostearate (GMS) nanoparticles by using three preparation methods namely microemulsion technique, magnetic stirring technique and temperature modulated solidification technique of which the latter two were developed in our laboratory. An anticancer drug 5-fluorouracil was incorporated in the SLNs prepared via the temperature modulated solidification process. Optimization of the magnetic stirring process was performed to evaluate how the physicochemical properties of the SLN was influenced by systematically varying process parameters including concentration of the lipid, concentration of the surfactant, type of surfactant, time of stirring and temperature of storage. The results demonstrated 1:2 GMS to tween 80 ratio, 150 ml dispersion medium and 45 min stirring at 4000 RPM speed provided an optimum formulation via the temperature modulated solidification process. SLN dispersions were lyophilized to stabilize the solid lipid nanoparticles and the lyophilizates exhibited good redispersibility. The SLNs were characterized by particle size analysis via dynamic light scattering (DLS), zeta potential, transmission electron microscopy (TEM), differential scanning calorimetry (DSC), drug encapsulation efficiency and in vitro drug release studies. Particle size of SLN dispersion prepared via the three preparation techniques was approximately 66 nm and that of redispersed lyophilizates was below 500 nm. TEM images showed spherical to oval particles that were less dense in the core with a well-defined shell and the particle size was in agreement with the particle size analysis data obtained by DLS. DSC thermograms of the lyophilized SLNs indicate a reduction in the crystallinity order of GMS particles. The drug encapsulation efficiency was found to be approximately 30%. In vitro drug release studies from redispersed lyophilized SLNs showed that 17 % of the encapsulated drug was released within 2 h. The SLNs prepared in our lab demonstrated characteristics that can potentially be utilized in an anticancer drug delivery system. Future in vitro cell culture and in vivo animal model studies will delineate compatibility and utility of these formulations in biological systems.
Hassanzadeh, Malihe; Hosseini Farahabadi, Elham; Yousefi, Zohreh; Kadkhodayan, Sima; Zarifmahmoudi, Leili; Sadeghi, Ramin
2016-09-07
Experience on sentinel node mapping in ovarian tumors is very limited. We evaluated the sentinel node concept in ovarian tumors using intra-operativeTc-99m-Phytate injection and lymphoscintigraphy imaging. Thirty-five patients with a pelvic mass due to an ovarian pathology were included in the study. The radiotracer was injected just after laparotomy and before removal of the tumor either beneath the normal cortex (10 patients) or in the utero-ovarian and suspensory ligaments of the ovary just beneath the peritoneum two injections of the radiotracer (25 patients). For malignant masses, the sentinel nodes were identified using a hand held gamma probe. Then standard pelvic and para-aortic lymphadenectomy was performed. In case of benign pathologies or borderline ovarian tumors on frozen section, lymphadenectomy was not performed. The morning after surgery, all patients were sent for lymphoscintigraphy imaging of the abdomen and pelvis. Sentinel node was identified only in 4 patients of the cortical injection group. At least one sentinel node could be identified in 21 patients of the sub-peritoneal group. Sentinel nodes were identified only in the para-aortic area in 21, pelvic/para-aortic areas in 2, and pelvic only area in 2 patients. Three patients had lymph node involvement and all had involved sentinel nodes (no false negative case). Sentinel node mapping using intra-operative injection of the radiotracer (in the utero-ovarian and suspensory ligaments of the ovary just beneath the peritoneum) is feasible in ovarian tumors. Technical aspects of this method should be explored in larger multicenter studies in the future.
NASA Astrophysics Data System (ADS)
Park-Martinez, Jayne Irene
The purpose of this study was to assess the effects of node-link mapping on students' meaningful learning and conceptual change in a 1-semester introductory life-science course. This study used node-link mapping to integrate and apply the National Research Council's (NRC, 2005) three principles of human learning: engaging students' prior knowledge, fostering their metacognition, and supporting their formulation of a scientific conceptual framework. The study was a quasi-experimental, pretest-posttest, control group design. The sample consisted of 68 primarily freshmen non-science majors enrolled in two intact sections of the targeted course. Both groups received the same teacher-centered instruction and student-centered activities designed to promote meaningful learning and conceptual change; however, the activity format differed. Control group activities were written; treatment group activities were node-link mapped. Prior to instruction, both groups demonstrated equivalent knowledge and misconceptions associated with genetics and evolution (GE), and ecology and environmental science (EE). Mean differences, pre-to-post instruction, on the GE and EE meaningful learning exam scores and the EE conceptual change inventory scores between the writing group (control) and the node-link mapping group (treatment) were analyzed using repeated measures MANOVAs. There were no significant mean pre-to-post differences between groups with respect to meaningful learning in the GE or EE units, or conceptual change in the EE unit. However, independent of group membership, the overall mean pre-to-post increases in meaningful learning and conceptual change were significant. These findings suggest that both node-link mapping and writing, when used in conjunction with the National Research Council's (NRC, 2005) three principles of human learning, can promote meaningful learning and conceptual change. The only significant interaction found with respect to meaningful learning, conceptual change, and learning styles (Kolb, 2005) was a positive effect of node-link mapping on converger's meaningful learning. However, that result was probably an artifact of small sample size rather than a true treatment effect. No other significant interactions were found. These results suggest that all students, regardless of their learning style, can benefit from either node-link mapping or writing to promote meaningful learning and conceptual change in general life-science courses.
Heterogeneous delays making parents synchronized: A coupled maps on Cayley tree model
NASA Astrophysics Data System (ADS)
Singh, Aradhana; Jalan, Sarika
2014-06-01
We study the phase synchronized clusters in the diffusively coupled maps on the Cayley tree networks for heterogeneous delay values. Cayley tree networks comprise of two parts: the inner nodes and the boundary nodes. We find that heterogeneous delays lead to various cluster states, such as; (a) cluster state consisting of inner nodes and boundary nodes, and (b) cluster state consisting of only boundary nodes. The former state may comprise of nodes from all the generations forming self-organized cluster or nodes from few generations yielding driven clusters depending upon on the parity of heterogeneous delay values. Furthermore, heterogeneity in delays leads to the lag synchronization between the siblings lying on the boundary by destroying the exact synchronization among them. The time lag being equal to the difference in the delay values. The Lyapunov function analysis sheds light on the destruction of the exact synchrony among the last generation nodes. To the end we discuss the relevance of our results with respect to their applications in the family business as well as in understanding the occurrence of genetic diseases.
System and method for image mapping and visual attention
NASA Technical Reports Server (NTRS)
Peters, II, Richard A. (Inventor)
2010-01-01
A method is described for mapping dense sensory data to a Sensory Ego Sphere (SES). Methods are also described for finding and ranking areas of interest in the images that form a complete visual scene on an SES. Further, attentional processing of image data is best done by performing attentional processing on individual full-size images from the image sequence, mapping each attentional location to the nearest node, and then summing attentional locations at each node.
System and method for image mapping and visual attention
NASA Technical Reports Server (NTRS)
Peters, II, Richard A. (Inventor)
2011-01-01
A method is described for mapping dense sensory data to a Sensory Ego Sphere (SES). Methods are also described for finding and ranking areas of interest in the images that form a complete visual scene on an SES. Further, attentional processing of image data is best done by performing attentional processing on individual full-size images from the image sequence, mapping each attentional location to the nearest node, and then summing all attentional locations at each node.
Kuo, Yung-Chih; Kuo, Chan-Ying
2008-03-03
Transport of antiretroviral agents across the blood-brain barrier (BBB) is of key importance to the treatment for the acquired immunodeficiency syndrome (AIDS). In this study, impact of exposure to electromagnetic field (EMF) on the permeability of saquinavir (SQV) across BBB was investigated. The in vitro BBB model was based on human brain-microvascular endothelial cells (HBMEC), and the concentration of SQV in receiver chamber of the transport system was evaluated. Polybutylcyanoacrylate (PBCA), methylmethacrylate-sulfopropylmethacrylate (MMA-SPM), and solid lipid nanoparticle (SLN) were employed as carriers for the delivery systems. Cytotoxicity of SLN decreased as content of cacao butter increased. Power of 5mV was apposite for the study on HBMEC without obvious apoptosis. Square wave produced greater permeability than sine and triangle waves. The carrier order on permeability of SQV across HBMEC monolayer under exposure to EMF was SLN>PBCA>MMA-SPM. Also, a larger frequency, modulation or depth of amplitude modulation (AM), or modulation or deviation of frequency modulation (FM) yielded a greater permeability. Besides, enhancement of permeability by AM wave was more significant than that by FM wave. Transport behavior of SQV across BBB was strongly influenced by the combination of nanoparticulate PBCA, MMA-SPM, and SLN with EMF exposure. This combination would be beneficial to the clinical application to the therapy of AIDS and other brain-related diseases.
Jiang, Chunyan; Wang, Hougen; Kang, Qianjin; Liu, Jing
2012-01-01
Salinomycin is widely used in animal husbandry as a food additive due to its antibacterial and anticoccidial activities. However, its biosynthesis had only been studied by feeding experiments with isotope-labeled precursors. A strategy with degenerate primers based on the polyether-specific epoxidase sequences was successfully developed to clone the salinomycin gene cluster. Using this strategy, a putative epoxidase gene, slnC, was cloned from the salinomycin producer Streptomyces albus XM211. The targeted replacement of slnC and subsequent trans-complementation proved its involvement in salinomycin biosynthesis. A 127-kb DNA region containing slnC was sequenced, including genes for polyketide assembly and release, oxidative cyclization, modification, export, and regulation. In order to gain insight into the salinomycin biosynthesis mechanism, 13 gene replacements and deletions were conducted. Including slnC, 7 genes were identified as essential for salinomycin biosynthesis and putatively responsible for polyketide chain release, oxidative cyclization, modification, and regulation. Moreover, 6 genes were found to be relevant to salinomycin biosynthesis and possibly involved in precursor supply, removal of aberrant extender units, and regulation. Sequence analysis and a series of gene replacements suggest a proposed pathway for the biosynthesis of salinomycin. The information presented here expands the understanding of polyether biosynthesis mechanisms and paves the way for targeted engineering of salinomycin activity and productivity. PMID:22156425
Chen, Jin; Wei, Ning; Lopez-Garcia, Maria; Ambrose, Dianna; Lee, Jason; Annelin, Colin; Peterson, Teresa
2017-08-01
Solid lipid nanoparticles (SLN) and nanostructured lipid carriers (NLC) have been studied as potential carriers for both dermal and transdermal drug delivery. SLN contain lipid droplets that are fully crystallized and have a highly-ordered crystalline structure. NLC are modified SLN in which the lipid phase contains both solid and liquid lipids at room temperature. SLN and NLC are thought to combine the advantages of polymeric particles, liposomes and emulsions. Therefore they provide high encapsulation percentages, better protection for incorporated actives and allow for control of desired release profile. In this work, Resveratrol, Vitamin E (VE), and Epigallocatechin Gallate (EGCG) all potent antioxidants known to provide protection to the skin, were formulated into lipid nanoparticles. Several different formulations were successfully developed and demonstrated high uniformity and stability. Both resveratrol and VE lipid nanoparticles provided effective protection of actives against UV induced degradation. However, lipid nanoparticles did not show protection from UV degradation for EGCG in this work. An active release study exhibited a sustained release of resveratrol over 70% after 24h. Skin penetration studies showed that lipid nanoparticles directionally improved the penetration of resveratrol through the stratum corneum. Our findings suggest that lipid nanoparticles are promising viable carriers for the delivery of resveratrol and VE to provide longlasting antioxidant benefits to the skin. Copyright © 2017 Elsevier B.V. All rights reserved.
González-Domínguez, Jorge; Remeseiro, Beatriz; Martín, María J
2017-02-01
The analysis of the interference patterns on the tear film lipid layer is a useful clinical test to diagnose dry eye syndrome. This task can be automated with a high degree of accuracy by means of the use of tear film maps. However, the time required by the existing applications to generate them prevents a wider acceptance of this method by medical experts. Multithreading has been previously successfully employed by the authors to accelerate the tear film map definition on multicore single-node machines. In this work, we propose a hybrid message-passing and multithreading parallel approach that further accelerates the generation of tear film maps by exploiting the computational capabilities of distributed-memory systems such as multicore clusters and supercomputers. The algorithm for drawing tear film maps is parallelized using Message Passing Interface (MPI) for inter-node communications and the multithreading support available in the C++11 standard for intra-node parallelization. The original algorithm is modified to reduce the communications and increase the scalability. The hybrid method has been tested on 32 nodes of an Intel cluster (with two 12-core Haswell 2680v3 processors per node) using 50 representative images. Results show that maximum runtime is reduced from almost two minutes using the previous only-multithreaded approach to less than ten seconds using the hybrid method. The hybrid MPI/multithreaded implementation can be used by medical experts to obtain tear film maps in only a few seconds, which will significantly accelerate and facilitate the diagnosis of the dry eye syndrome. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Musician Map: visualizing music collaborations over time
NASA Astrophysics Data System (ADS)
Yim, Ji-Dong; Shaw, Chris D.; Bartram, Lyn
2009-01-01
In this paper we introduce Musician Map, a web-based interactive tool for visualizing relationships among popular musicians who have released recordings since 1950. Musician Map accepts search terms from the user, and in turn uses these terms to retrieve data from MusicBrainz.org and AudioScrobbler.net, and visualizes the results. Musician Map visualizes relationships of various kinds between music groups and individual musicians, such as band membership, musical collaborations, and linkage to other artists that are generally regarded as being similar in musical style. These relationships are plotted between artists using a new timeline-based visualization where a node in a traditional node-link diagram has been transformed into a Timeline-Node, which allows the visualization of an evolving entity over time, such as the membership in a band. This allows the user to pursue social trend queries such as "Do Hip-Hop artists collaborate differently than Rock artists".
Inoue, Kentaro; Shimozono, Shinichi; Yoshida, Hideaki; Kurata, Hiroyuki
2012-01-01
Background For visualizing large-scale biochemical network maps, it is important to calculate the coordinates of molecular nodes quickly and to enhance the understanding or traceability of them. The grid layout is effective in drawing compact, orderly, balanced network maps with node label spaces, but existing grid layout algorithms often require a high computational cost because they have to consider complicated positional constraints through the entire optimization process. Results We propose a hybrid grid layout algorithm that consists of a non-grid, fast layout (preprocessor) algorithm and an approximate pattern matching algorithm that distributes the resultant preprocessed nodes on square grid points. To demonstrate the feasibility of the hybrid layout algorithm, it is characterized in terms of the calculation time, numbers of edge-edge and node-edge crossings, relative edge lengths, and F-measures. The proposed algorithm achieves outstanding performances compared with other existing grid layouts. Conclusions Use of an approximate pattern matching algorithm quickly redistributes the laid-out nodes by fast, non-grid algorithms on the square grid points, while preserving the topological relationships among the nodes. The proposed algorithm is a novel use of the pattern matching, thereby providing a breakthrough for grid layout. This application program can be freely downloaded from http://www.cadlive.jp/hybridlayout/hybridlayout.html. PMID:22679486
Inoue, Kentaro; Shimozono, Shinichi; Yoshida, Hideaki; Kurata, Hiroyuki
2012-01-01
For visualizing large-scale biochemical network maps, it is important to calculate the coordinates of molecular nodes quickly and to enhance the understanding or traceability of them. The grid layout is effective in drawing compact, orderly, balanced network maps with node label spaces, but existing grid layout algorithms often require a high computational cost because they have to consider complicated positional constraints through the entire optimization process. We propose a hybrid grid layout algorithm that consists of a non-grid, fast layout (preprocessor) algorithm and an approximate pattern matching algorithm that distributes the resultant preprocessed nodes on square grid points. To demonstrate the feasibility of the hybrid layout algorithm, it is characterized in terms of the calculation time, numbers of edge-edge and node-edge crossings, relative edge lengths, and F-measures. The proposed algorithm achieves outstanding performances compared with other existing grid layouts. Use of an approximate pattern matching algorithm quickly redistributes the laid-out nodes by fast, non-grid algorithms on the square grid points, while preserving the topological relationships among the nodes. The proposed algorithm is a novel use of the pattern matching, thereby providing a breakthrough for grid layout. This application program can be freely downloaded from http://www.cadlive.jp/hybridlayout/hybridlayout.html.
Ishizaki, Jun; Saito, Kazuyoshi; Nawata, Masao; Mizuno, Yasushi; Tokunaga, Mikiko; Sawamukai, Norifumi; Tamura, Masahito; Hirata, Shintaro; Yamaoka, Kunihiro; Hasegawa, Hitoshi; Tanaka, Yoshiya
2015-03-01
The aim of this study was to clarify the clinical characteristics and predictors of silent LN (SLN), a type of LN in SLE without abnormal urinalysis or renal impairment. Of 182 patients who underwent renal biopsy, 48 did not present with abnormal urinalysis or renal impairment at the time of biopsy. The patients with LN (SLN group, n = 36) and those without LN (non-LN group, n = 12) were compared with respect to their baseline characteristics. Bivariate analysis comprised Fisher's exact test and the Mann-Whitney test, whereas multivariate analysis employed binomial logistic regression analysis. LN was histopathologically identified in 36 of 48 patients. According to the International Society of Nephrology/Renal Pathology Society classification, 72% of the SLN patients were classified as having class I/II, with a further 17% having class III/IV. Bivariate analyses indicated that platelet count, serum albumin, complement components (C3 and C4), complement haemolytic activity (CH50), anti-Sm antibody titre and anti-ribonucleoprotein antibody titre were significantly different between groups. Multivariate analysis indicated that CH50 and C3 titres were significantly lower in the SLN group, whereas anti-Sm antibody titre was significantly higher. The cut-off titre, calculated based on the receiver operating characteristic curve for CH50, was 33 U/ml, with a sensitivity and specificity of 89% and 83%, respectively. The cut-off titre for anti-Sm antibodies was 9 U/ml, with a sensitivity and specificity of 74% and 83%, respectively. Low titres of CH50 and C3 and a high titre of anti-Sm antibody were identified as predictors of SLN. © The Author 2014. Published by Oxford University Press on behalf of the British Society for Rheumatology. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Contribution of the lateral lemniscus to the control of swallowing in decerebrate cats.
Ota, R; Takakusaki, K; Katada, A; Harada, H; Nonaka, S; Harabuchi, Y
2013-12-19
Lateral lemniscus, a relay nucleus of auditory sensation, is involved in the control of phonatory movements such as human speech and vocalization of animals. The present study was designed to test whether neurons in the lateral lemniscus contributed to the control of swallowing, one of non-phonic oro-pharyngolaryngeal movements. In acutely decerebrated cats (n=15), swallowing was induced by electrical stimulation (20-80μA at 10Hz for 20s with rectangular pulses of 0.2ms duration) delivered to the superior laryngeal nerve (SLN). Repetitive electrical stimulation (30-50μA at 50Hz for 10-20s) applied to the dorsal nucleus of the lateral lemniscus (LLD) increased the number and reduced the latency to the onset of the SLN-induced swallowing. On the other hand, stimulation of the ventral nucleus of the lateral lemniscus and the paralemniscal area, corresponding to the ventrolateral part of the parabrachial nucleus and the Kölliker-Fuse nucleus, often suppressed the SLN-induced swallowing. Microinjection of NMDA (0.1-0.15μl, 5.0-10mM) into the LLD through a stereotaxically placed glass micropipette facilitated the SLN-induced swallowing, i.e., the number was increased and the latency of swallowing was reduced. We also injected muscimol (a gamma amino-butyric acid (GABA)A receptor agonist), bicuculline (a GABAA receptor antagonist) and baclofen (a GABAB receptor agonist) into the LLD (0.1-0.15μl and 5.0mM for each substance). It was observed that an injection of muscimol suppressed the SLN-induced swallowing. However, an injection of bicuculline facilitated the swallowing. An injection of baclofen did not alter the swallowing. These results suggest the presence of functional topography in the lateral lemniscus and the paralemniscal area in relation to the control of swallowing. The facilitatory LLD-effects on swallowing are modulated by glutamatergic and GABAergic receptors on neurons in the LLD. Copyright © 2013 IBRO. Published by Elsevier Ltd. All rights reserved.
Dianzani, Chiara; Foglietta, Federica; Ferrara, Benedetta; Rosa, Arianna Carolina; Muntoni, Elisabetta; Gasco, Paolo; Della Pepa, Carlo; Canaparo, Roberto; Serpe, Loredana
2017-01-01
AIM To improve anti-inflammatory activity while reducing drug doses, we developed a nanoformulation carrying dexamethasone and butyrate. METHODS Dexamethasone cholesteryl butyrate-solid lipid nanoparticles (DxCb-SLN) were obtained with the warm microemulsion method. The anti-inflammatory activity of this novel nanoformulation has been investigated in vitro (cell adhesion to human vascular endothelial cells and pro-inflammatory cytokine release by lipopolysaccharide-induced polymorphonuclear cells) and in vivo (disease activity index and cytokine plasma concentrations in a dextran sulfate sodium-induced mouse colitis) models. Each drug was also administered separately to compare its effects with those induced by their co-administration in SLN at the same concentrations. RESULTS DxCb-SLN at the lowest concentration tested (Dx 2.5 nmol/L and Cb 0.1 μmol/L) were able to exert a more than additive effect compared to the sum of the individual effects of each drug, inducing a significant in vitro inhibition of cell adhesion and a significant decrease of pro-inflammatory cytokine (IL-1β and TNF-α) in both in vitro and in vivo models. Notably, only the DxCb nanoformulation administration was able to achieve a significant cytokine decrease compared to the cytokine plasma concentration of the untreated mice with dextran sulfate sodium-induced colitis. Specifically, DxCb-SLN induced a IL-1β plasma concentration of 61.77% ± 3.19%, whereas Dx or Cb used separately induced a concentration of 90.0% ± 2.8% and 91.40% ± 7.5%, respectively; DxCb-SLN induced a TNF-α plasma concentration of 30.8% ± 8.9%, whereas Dx or Cb used separately induced ones of 99.5% ± 4.9% and 71.1% ± 10.9%, respectively. CONCLUSION Our results indicate that the co-administration of dexamethasone and butyrate by nanoparticles may be beneficial for inflammatory bowel disease treatment. PMID:28694660
Function Allocation in a Robust Distributed Real-Time Environment
1991-12-01
fundamental characteristic of a distributed system is its ability to map individual logical functions of an application program onto many physical nodes... how much of a node’s processor time is scheduled for function processing. IMC is the function- to -function communication required to facilitate...indicator of how much excess processor time a node has. The reconfiguration algorithms use these variables to determine the most appropriate node(s) to
A graph theoretic approach to scene matching
NASA Technical Reports Server (NTRS)
Ranganath, Heggere S.; Chipman, Laure J.
1991-01-01
The ability to match two scenes is a fundamental requirement in a variety of computer vision tasks. A graph theoretic approach to inexact scene matching is presented which is useful in dealing with problems due to imperfect image segmentation. A scene is described by a set of graphs, with nodes representing objects and arcs representing relationships between objects. Each node has a set of values representing the relations between pairs of objects, such as angle, adjacency, or distance. With this method of scene representation, the task in scene matching is to match two sets of graphs. Because of segmentation errors, variations in camera angle, illumination, and other conditions, an exact match between the sets of observed and stored graphs is usually not possible. In the developed approach, the problem is represented as an association graph, in which each node represents a possible mapping of an observed region to a stored object, and each arc represents the compatibility of two mappings. Nodes and arcs have weights indicating the merit or a region-object mapping and the degree of compatibility between two mappings. A match between the two graphs corresponds to a clique, or fully connected subgraph, in the association graph. The task is to find the clique that represents the best match. Fuzzy relaxation is used to update the node weights using the contextual information contained in the arcs and neighboring nodes. This simplifies the evaluation of cliques. A method of handling oversegmentation and undersegmentation problems is also presented. The approach is tested with a set of realistic images which exhibit many types of sementation errors.
Fluorescence spectroscopy using indocyanine green for lymph node mapping
NASA Astrophysics Data System (ADS)
Haj-Hosseini, Neda; Behm, Pascal; Shabo, Ivan; Wârdell, Karin
2014-02-01
The principles of cancer treatment has for years been radical resection of the primary tumor. In the oncologic surgeries where the affected cancer site is close to the lymphatic system, it is as important to detect the draining lymph nodes for metastasis (lymph node mapping). As a replacement for conventional radioactive labeling, indocyanine green (ICG) has shown successful results in lymph node mapping; however, most of the ICG fluorescence detection techniques developed are based on camera imaging. In this work, fluorescence spectroscopy using a fiber-optical probe was evaluated on a tissue-like ICG phantom with ICG concentrations of 6-64 μM and on breast tissue from five patients. Fiber-optical based spectroscopy was able to detect ICG fluorescence at low intensities; therefore, it is expected to increase the detection threshold of the conventional imaging systems when used intraoperatively. The probe allows spectral characterization of the fluorescence and navigation in the tissue as opposed to camera imaging which is limited to the view on the surface of the tissue.
Ultrafast and scalable cone-beam CT reconstruction using MapReduce in a cloud computing environment.
Meng, Bowen; Pratx, Guillem; Xing, Lei
2011-12-01
Four-dimensional CT (4DCT) and cone beam CT (CBCT) are widely used in radiation therapy for accurate tumor target definition and localization. However, high-resolution and dynamic image reconstruction is computationally demanding because of the large amount of data processed. Efficient use of these imaging techniques in the clinic requires high-performance computing. The purpose of this work is to develop a novel ultrafast, scalable and reliable image reconstruction technique for 4D CBCT∕CT using a parallel computing framework called MapReduce. We show the utility of MapReduce for solving large-scale medical physics problems in a cloud computing environment. In this work, we accelerated the Feldcamp-Davis-Kress (FDK) algorithm by porting it to Hadoop, an open-source MapReduce implementation. Gated phases from a 4DCT scans were reconstructed independently. Following the MapReduce formalism, Map functions were used to filter and backproject subsets of projections, and Reduce function to aggregate those partial backprojection into the whole volume. MapReduce automatically parallelized the reconstruction process on a large cluster of computer nodes. As a validation, reconstruction of a digital phantom and an acquired CatPhan 600 phantom was performed on a commercial cloud computing environment using the proposed 4D CBCT∕CT reconstruction algorithm. Speedup of reconstruction time is found to be roughly linear with the number of nodes employed. For instance, greater than 10 times speedup was achieved using 200 nodes for all cases, compared to the same code executed on a single machine. Without modifying the code, faster reconstruction is readily achievable by allocating more nodes in the cloud computing environment. Root mean square error between the images obtained using MapReduce and a single-threaded reference implementation was on the order of 10(-7). Our study also proved that cloud computing with MapReduce is fault tolerant: the reconstruction completed successfully with identical results even when half of the nodes were manually terminated in the middle of the process. An ultrafast, reliable and scalable 4D CBCT∕CT reconstruction method was developed using the MapReduce framework. Unlike other parallel computing approaches, the parallelization and speedup required little modification of the original reconstruction code. MapReduce provides an efficient and fault tolerant means of solving large-scale computing problems in a cloud computing environment.
Ultrafast and scalable cone-beam CT reconstruction using MapReduce in a cloud computing environment
Meng, Bowen; Pratx, Guillem; Xing, Lei
2011-01-01
Purpose: Four-dimensional CT (4DCT) and cone beam CT (CBCT) are widely used in radiation therapy for accurate tumor target definition and localization. However, high-resolution and dynamic image reconstruction is computationally demanding because of the large amount of data processed. Efficient use of these imaging techniques in the clinic requires high-performance computing. The purpose of this work is to develop a novel ultrafast, scalable and reliable image reconstruction technique for 4D CBCT/CT using a parallel computing framework called MapReduce. We show the utility of MapReduce for solving large-scale medical physics problems in a cloud computing environment. Methods: In this work, we accelerated the Feldcamp–Davis–Kress (FDK) algorithm by porting it to Hadoop, an open-source MapReduce implementation. Gated phases from a 4DCT scans were reconstructed independently. Following the MapReduce formalism, Map functions were used to filter and backproject subsets of projections, and Reduce function to aggregate those partial backprojection into the whole volume. MapReduce automatically parallelized the reconstruction process on a large cluster of computer nodes. As a validation, reconstruction of a digital phantom and an acquired CatPhan 600 phantom was performed on a commercial cloud computing environment using the proposed 4D CBCT/CT reconstruction algorithm. Results: Speedup of reconstruction time is found to be roughly linear with the number of nodes employed. For instance, greater than 10 times speedup was achieved using 200 nodes for all cases, compared to the same code executed on a single machine. Without modifying the code, faster reconstruction is readily achievable by allocating more nodes in the cloud computing environment. Root mean square error between the images obtained using MapReduce and a single-threaded reference implementation was on the order of 10−7. Our study also proved that cloud computing with MapReduce is fault tolerant: the reconstruction completed successfully with identical results even when half of the nodes were manually terminated in the middle of the process. Conclusions: An ultrafast, reliable and scalable 4D CBCT/CT reconstruction method was developed using the MapReduce framework. Unlike other parallel computing approaches, the parallelization and speedup required little modification of the original reconstruction code. MapReduce provides an efficient and fault tolerant means of solving large-scale computing problems in a cloud computing environment. PMID:22149842
Martínez-Palones, José M; Gil-Moreno, Antonio; Pérez-Benavente, María A; Roca, Isabel; Xercavins, Jordi
2004-03-01
We investigated the feasibility of sentinel lymph node identification using radioisotopic lymphatic mapping with technetium-99m-labeled human serum albumin and isosulfan blue dye injection in patients undergoing radical hysterectomy with pelvic lymphadenectomy for treatment of early cervical cancer. Between September 2000 and October 2002, 25 patients with cervical cancer FIGO stage I (n=24) or stage II (n=1) underwent sentinel lymph node detection with preoperative lymphoscintigraphy (technetium-99m colloid albumin injection around the tumor) and intraoperative lymphatic mapping with blue dye and a handheld or laparoscopic gamma probe. Complete pelvic or paraaortic lymphadenectomy was performed in all cases by open surgery or laparoscopic surgery. In 23 evaluable patients, a total of 51 sentinel lymph nodes were detected by lymphoscintigraphy (mean 2.21 nodes per patient). Intraoperatively, 61 sentinel lymph nodes were identified, with a mean of 2.52 nodes per patient by gamma probe and a mean of 1.94 nodes per patient after isosulfan blue injection. Forty percent of sentinel nodes were found in the interiliac region and 25% in the external iliac area. Microscopic nodal metastases (four nodes) were confirmed in 12% of cases. All these lymph nodes were previously detected as sentinel lymph nodes. The remaining 419 nodes after pelvic lymphadenectomy were histologically negative. Sentinel lymph node identification with technetium-99m-labeled nanocolloid combined with blue dye injection is feasible and showed a 100% negative predictive value, and potentially identified women in whom lymph node dissection can be avoided.
Multifunctional Polymer Microbubbles for Advanced Sentinel Lymph Node Imaging and Mapping
2012-03-01
undesired PMA attached to microbubble surface. Figure 1: One-pot polymer -lipid microbubbles. (a) Synthesis of thiolated poly(acrylic acid) with...Award Number: W81XWH-11-1-0215 TITLE: Multifunctional Polymer Microbubbles for Advanced Sentinel...February 2012 4. TITLE AND SUBTITLE 5a. CONTRACT NUMBER Multifunctional Polymer Microbubbles for Advanced Sentinel Lymph Node Imaging and Mapping 5b
A quantitative approach to measure road network information based on edge diversity
NASA Astrophysics Data System (ADS)
Wu, Xun; Zhang, Hong; Lan, Tian; Cao, Weiwei; He, Jing
2015-12-01
The measure of map information has been one of the key issues in assessing cartographic quality and map generalization algorithms. It is also important for developing efficient approaches to transfer geospatial information. Road network is the most common linear object in real world. Approximately describe road network information will benefit road map generalization, navigation map production and urban planning. Most of current approaches focused on node diversities and supposed that all the edges are the same, which is inconsistent to real-life condition, and thus show limitations in measuring network information. As real-life traffic flow are directed and of different quantities, the original undirected vector road map was first converted to a directed topographic connectivity map. Then in consideration of preferential attachment in complex network study and rich-club phenomenon in social network, the from and to weights of each edge are assigned. The from weight of a given edge is defined as the connectivity of its end node to the sum of the connectivities of all the neighbors of the from nodes of the edge. After getting the from and to weights of each edge, edge information, node information and the whole network structure information entropies could be obtained based on information theory. The approach has been applied to several 1 square mile road network samples. Results show that information entropies based on edge diversities could successfully describe the structural differences of road networks. This approach is a complementarity to current map information measurements, and can be extended to measure other kinds of geographical objects.
Efficient algorithms for dilated mappings of binary trees
NASA Technical Reports Server (NTRS)
Iqbal, M. Ashraf
1990-01-01
The problem is addressed to find a 1-1 mapping of the vertices of a binary tree onto those of a target binary tree such that the son of a node on the first binary tree is mapped onto a descendent of the image of that node in the second binary tree. There are two natural measures of the cost of this mapping, namely the dilation cost, i.e., the maximum distance in the target binary tree between the images of vertices that are adjacent in the original tree. The other measure, expansion cost, is defined as the number of extra nodes/edges to be added to the target binary tree in order to ensure a 1-1 mapping. An efficient algorithm to find a mapping of one binary tree onto another is described. It is shown that it is possible to minimize one cost of mapping at the expense of the other. This problem arises when designing pipelined arithmetic logic units (ALU) for special purpose computers. The pipeline is composed of ALU chips connected in the form of a binary tree. The operands to the pipeline can be supplied to the leaf nodes of the binary tree which then process and pass the results up to their parents. The final result is available at the root. As each new application may require a distinct nesting of operations, it is useful to be able to find a good mapping of a new binary tree over existing ALU tree. Another problem arises if every distinct required binary tree is known beforehand. Here it is useful to hardwire the pipeline in the form of a minimal supertree that contains all required binary trees.
Solid lipid nanoparticles as carrier for sunscreens: in vitro release and in vivo skin penetration.
Wissing, S A; Müller, R H
2002-06-17
The aim of this study was the comparison of two different formulations (solid lipid nanoparticles (SLN) and conventional o/w emulsion) as carrier systems for the molecular sunscreen oxybenzone. The influence of the carrier on the rate of release was studied in vitro with a membrane-free model. The release rate could be decreased by up to 50% with the SLN formulation. Further in vitro measurements with static Franz diffusion cells were performed. In vivo, penetration of oxybenzone into stratum corneum on the forearm was investigated by the tape stripping method. It was shown that the rate of release is strongly dependent upon the formulation and could be decreased by 30-60% in SLN formulations. In all test models, oxybenzone was released and penetrated into human skin more quickly and to a greater extent from the emulsions. The rate of release also depends upon the total concentration of oxybenzone in the formulation. In vitro-in vivo correlations could be made qualitatively.
Martínez-Acevedo, Lizbeth; Zambrano-Zaragoza, María de la Luz; Vidal-Romero, Gustavo; Mendoza-Elvira, Susana; Quintanar-Guerrero, David
2018-05-02
The aim of this study was to develop solid lipid nanoparticles (SLN) and introduce them into a direct compression process to evaluate their lubricant properties. The study consisted of preparing glyceryl behenate SLN (Compritol® 888 ATO) by hot dispersion, and magnesium stearate SLN by a novel nanoprecipitation/ion exchange method. The ejection force was measured for nanosystems and raw materials in a formulation typically used for direct compression. The smallest particle sizes obtained were 456 nm for Compritol® 888 ATO and 330 nm for magnesium stearate. Results show that the NPs used as lubricants in a direct compression model formulation provided efficient lubrication by maintaining the lubricating properties of the system, thereby decreasing the amount of lubricant used compared to the raw material. The lubricating effect showed an increase of 15-30% for magnesium stearate and Compritol® 888 ATO, compared to the raw material at concentrations above 2%. Copyright © 2018 Elsevier B.V. All rights reserved.
Shah, Malay; Agrawal, Yadvendra
2012-01-01
This investigation was undertaken to develop glyceryl monostearate (Geleol)-based solid lipid nanoparticles (SLNs) of a hydrophilic drug ciprofloxacin HCl. Hansen's solubility parameter study was carried out in screening of a suitable carrier and solvent system. Subsequently, SLNs were prepared by solvent diffusion evaporation method and investigated for particle size, polydispersity index (PDI), zeta potential (ZP), entrapment efficiency (EE) and drug release behaviour. Variations in SLN composition resulted in particle sizes between 170 and 810 nm and ZPs between 8 and 14 mV. The maximum EE was found to be 26.3% with particle size of 188.8 nm. SLN can sustain the release of drug for up to 15 h and it shows Higuchi matrix model as the best-fitted model. SLNs were stable without aggregation of particles under storage conditions. The results of this study provide the framework for further study involving the SLN formulation for hydrophilic drug molecule.
[Role of sentinel lymph nodes and lymphatic mapping of colorectal cancer].
Ivanov, K; Kolev, N; Ignatov, V; Temelkov, T; Madzhov, R
2005-01-01
The accuracy of staging of colorectal cancer is dependable of number of lymph nodes, colected and investegated from the pathologist. Moreover 50% of newfounded cases with colorectal cancer are diagnosed as I or II stage of the desease. Between 15% and 20% of these patients develop regional or distant metastases around 5 years after the examination, despite of the radical surgery. This may be due to pathological "understaging" (decrease of the stage), becouse of missed micrometastases, which size often is smaller than 5 mm. High accurate and specific pathologoanatomical methods for "ultrastaging" are cost-expensive, therefore their selective application to labeled sentinel lymph nodes has a economical benefit and saves a time. Moreover it is decreasing the understaging effect, assosiated with convectional pathologoanatomical investigaton. In the future, the technical progress will develop the intensive competiton between the sentinel lymph node mapping and the improved imaging diagnostic techniques as flurodeoxyglucose (18FDG), positron emision tomography (PET), or the other molecular imaging techniques. Unfortunately, the limited spatial resolution of these techniques, do not allow to be used for tumor staging as sentinel lymph node techniques. Therefore the sentinel lymphnode mapping become the choice of the lymphnode staging technique.
Mapping to Irregular Torus Topologies and Other Techniques for Petascale Biomolecular Simulation
Phillips, James C.; Sun, Yanhua; Jain, Nikhil; Bohm, Eric J.; Kalé, Laxmikant V.
2014-01-01
Currently deployed petascale supercomputers typically use toroidal network topologies in three or more dimensions. While these networks perform well for topology-agnostic codes on a few thousand nodes, leadership machines with 20,000 nodes require topology awareness to avoid network contention for communication-intensive codes. Topology adaptation is complicated by irregular node allocation shapes and holes due to dedicated input/output nodes or hardware failure. In the context of the popular molecular dynamics program NAMD, we present methods for mapping a periodic 3-D grid of fixed-size spatial decomposition domains to 3-D Cray Gemini and 5-D IBM Blue Gene/Q toroidal networks to enable hundred-million atom full machine simulations, and to similarly partition node allocations into compact domains for smaller simulations using multiple-copy algorithms. Additional enabling techniques are discussed and performance is reported for NCSA Blue Waters, ORNL Titan, ANL Mira, TACC Stampede, and NERSC Edison. PMID:25594075
VB12-coated Gel-Core-SLN containing insulin: Another way to improve oral absorption.
He, Haibing; Wang, Puxiu; Cai, Cuifang; Yang, Rui; Tang, Xing
2015-09-30
To improve the oral absorption of insulin, a novel carrier of Vitamin B12 (VB12) gel core solid lipid nanopaticles (Gel-Core-SLN, GCSLN) was designed with a gel core, lipid matrix and VB12-coated surface. VB12-stearate was synthesized and characterized by infrared spectroscopy (IR), nuclear magnetic resonance spectroscopy (NMR) and mass spectrometry (MS). Sol-gel conversion following ultrasonic heating and double emulsion technology were combined to implant the insulin-containing gel into solid lipid nanoparticles (SLN). The influence of the mode of administration, food, the amount of VB12-stearate and the particle size on the oral absorption of insulin incorporated in the VB12-GCSLN was investigated. The determined partition coefficient (LogP) of VB12-stearate in a dichloromethane (DCM)-water system was 3.4. This new structure of VB12-GCSLN had higher insulin encapsulation efficiency (EE) of 55.9%, a lower burst release of less than 10% in the first 2h. In vivo studies demonstrated that stronger absorption of insulin with a relative pharmacological availability (PA) of 9.31% compared with the normal insulin-loaded SLN and GCSLN and fairly stable blood glucose levels up to 12h were maintained without any sharp fluctuations. This study suggests that VB12-GCSLN containing insulin appears to be a promising nano carrier for oral delivery of biomacromolecules with relatively high pharmacological availability. Copyright © 2015 Elsevier B.V. All rights reserved.
Delgado, Diego; del Pozo-Rodríguez, Ana; Solinís, Maria Ángeles; Avilés-Triqueros, Marcelino; Weber, Bernhard H F; Fernández, Eduardo; Gascón, Alicia R
2012-04-01
The goal of the present study was to analyze the potential application of nonviral vectors based on solid lipid nanoparticles (SLN) for the treatment of ocular diseases by gene therapy, specifically X-linked juvenile retinoschisis (XLRS). Vectors were prepared with SLN, dextran, protamine, and a plasmid (pCMS-EGFP or pCEP4-RS1). Formulations were characterized and the in vitro transfection capacity as well as the cellular uptake and the intracellular trafficking were studied in ARPE-19 cells. Formulations were also tested in vivo in Wistar rat eyes, and the efficacy was studied by monitoring the expression of enhanced green fluorescent protein (EGFP) after intravitreal, subretinal, and topical administration. The presence of dextran and protamine in the SLN improved greatly the expression of retinoschisin and EGFP in ARPE-19 cells. The nuclear localization signals of protamine, its ability to protect the DNA, and a shift in the entry mechanism from caveola-mediated to clathrin-mediated endocytosis promoted by the dextran, justify the increase in transfection. After ocular administration of the dextran-protamine-DNA-SLN complex to rat eyes, we detected the expression of EGFP in various types of cells depending on the administration route. Our vectors were also able to transfect corneal cells after topical application. We have demonstrated the potential usefulness of our nonviral vectors loaded with XLRS1 plasmid and provided evidence for their potential application for the management or treatment of degenerative retinal disorders as well as ocular surface diseases.
Saliency Detection via Absorbing Markov Chain With Learnt Transition Probability.
Lihe Zhang; Jianwu Ai; Bowen Jiang; Huchuan Lu; Xiukui Li
2018-02-01
In this paper, we propose a bottom-up saliency model based on absorbing Markov chain (AMC). First, a sparsely connected graph is constructed to capture the local context information of each node. All image boundary nodes and other nodes are, respectively, treated as the absorbing nodes and transient nodes in the absorbing Markov chain. Then, the expected number of times from each transient node to all other transient nodes can be used to represent the saliency value of this node. The absorbed time depends on the weights on the path and their spatial coordinates, which are completely encoded in the transition probability matrix. Considering the importance of this matrix, we adopt different hierarchies of deep features extracted from fully convolutional networks and learn a transition probability matrix, which is called learnt transition probability matrix. Although the performance is significantly promoted, salient objects are not uniformly highlighted very well. To solve this problem, an angular embedding technique is investigated to refine the saliency results. Based on pairwise local orderings, which are produced by the saliency maps of AMC and boundary maps, we rearrange the global orderings (saliency value) of all nodes. Extensive experiments demonstrate that the proposed algorithm outperforms the state-of-the-art methods on six publicly available benchmark data sets.
Scanning elastic scattering spectroscopy detects metastatic breast cancer in sentinel lymph nodes
NASA Astrophysics Data System (ADS)
Austwick, Martin R.; Clark, Benjamin; Mosse, Charles A.; Johnson, Kristie; Chicken, D. Wayne; Somasundaram, Santosh K.; Calabro, Katherine W.; Zhu, Ying; Falzon, Mary; Kocjan, Gabrijela; Fearn, Tom; Bown, Stephen G.; Bigio, Irving J.; Keshtgar, Mohammed R. S.
2010-07-01
A novel method for rapidly detecting metastatic breast cancer within excised sentinel lymph node(s) of the axilla is presented. Elastic scattering spectroscopy (ESS) is a point-contact technique that collects broadband optical spectra sensitive to absorption and scattering within the tissue. A statistical discrimination algorithm was generated from a training set of nearly 3000 clinical spectra and used to test clinical spectra collected from an independent set of nodes. Freshly excised nodes were bivalved and mounted under a fiber-optic plate. Stepper motors raster-scanned a fiber-optic probe over the plate to interrogate the node's cut surface, creating a 20×20 grid of spectra. These spectra were analyzed to create a map of cancer risk across the node surface. Rules were developed to convert these maps to a prediction for the presence of cancer in the node. Using these analyses, a leave-one-out cross-validation to optimize discrimination parameters on 128 scanned nodes gave a sensitivity of 69% for detection of clinically relevant metastases (71% for macrometastases) and a specificity of 96%, comparable to literature results for touch imprint cytology, a standard technique for intraoperative diagnosis. ESS has the advantage of not requiring a pathologist to review the tissue sample.
Levenback, Charles F.; Ali, Shamshad; Coleman, Robert L.; Gold, Michael A.; Fowler, Jeffrey M.; Judson, Patricia L.; Bell, Maria C.; De Geest, Koen; Spirtos, Nick M.; Potkul, Ronald K.; Leitao, Mario M.; Bakkum-Gamez, Jamie N.; Rossi, Emma C.; Lentz, Samuel S.; Burke, James J.; Van Le, Linda; Trimble, Cornelia L.
2012-01-01
Purpose To determine the safety of sentinel lymph node biopsy as a replacement for inguinal femoral lymphadenectomy in selected women with vulvar cancer. Patients and Methods Eligible women had squamous cell carcinoma, at least 1-mm invasion, and tumor size ≥ 2 cm and ≤ 6 cm. The primary tumor was limited to the vulva, and there were no groin lymph nodes that were clinically suggestive of cancer. All women underwent intraoperative lymphatic mapping, sentinel lymph node biopsy, and inguinal femoral lymphadenectomy. Histologic ultra staging of the sentinel lymph node was prescribed. Results In all, 452 women underwent the planned procedures, and 418 had at least one sentinel lymph node identified. There were 132 node-positive women, including 11 (8.3%) with false-negative nodes. Twenty-three percent of the true-positive patients were detected by immunohistochemical analysis of the sentinel lymph node. The sensitivity was 91.7% (90% lower confidence bound, 86.7%) and the false-negative predictive value (1-negative predictive value) was 3.7% (90% upper confidence bound, 6.1%). In women with tumor less than 4 cm, the false-negative predictive value was 2.0% (90% upper confidence bound, 4.5%). Conclusion Sentinel lymph node biopsy is a reasonable alternative to inguinal femoral lymphadenectomy in selected women with squamous cell carcinoma of the vulva. PMID:22753905
NASA Astrophysics Data System (ADS)
Douma, M.; Ligierko, G.; Angelov, I.
2008-10-01
The need for information has increased exponentially over the past decades. The current systems for constructing, exploring, classifying, organizing, and searching information face the growing challenge of enabling their users to operate efficiently and intuitively in knowledge-heavy environments. This paper presents SpicyNodes, an advanced user interface for difficult interaction contexts. It is based on an underlying structure known as a radial map, which allows users to manipulate and interact in a natural manner with entities called nodes. This technology overcomes certain limitations of existing solutions and solves the problem of browsing complex sets of linked information. SpicyNodes is also an organic system that projects users into a living space, stimulating exploratory behavior and fostering creative thought. Our interactive radial layout is used for educational purposes and has the potential for numerous other applications.
Barrett, Eoin; Hayes, Maria; O'Connor, Paula; Gardiner, Gillian; Fitzgerald, Gerald F.; Stanton, Catherine; Ross, R. Paul; Hill, Colin
2007-01-01
Lactobacillus salivarius DPC6005, a porcine intestinal isolate, produces a two-component bacteriocin, salivaricin P, with homology to ABP-118 produced by a human probiotic L. salivarius strain. Indeed, molecular characterization revealed that while the peptides Sln1 and ABP-118α are identical, their companion peptides (Sln2 and ABP-118β, respectively) differ by two amino acids. This observation suggests that two-component bacteriocins may be a common feature of intestinal L. salivarius strains. PMID:17416691
Meta-analysis of aberrant lymphatic drainage in recurrent breast cancer.
Ahmed, M; Baker, R; Rubio, I T
2016-11-01
Sentinel node biopsy (SNB) in recurrent breast cancer offers targeted axillary staging compared with axillary lymph node dissection (ALND) or no treatment. The evidence for lymphatic mapping in recurrent breast cancer is reviewed, focusing on aberrant drainage and its implications for patient management. A meta-analysis of studies evaluating lymphatic mapping in recurrent breast cancer was performed. Outcomes included sentinel node identification, aberrant lymphatic pathways and metastatic node rates in aberrant drainage and ipsilateral axilla. Pooled odds ratios (ORs) and 95 per cent confidence intervals (c.i.) were estimated using fixed-effect analyses, or random-effects analyses in the event of statistically significant heterogeneity. Seven studies reported data on lymphatic mapping in 1053 patients with recurrent breast cancer. The intraoperative sentinel node identification rate was 59·6 (95 per cent c.i. 56·7 to 62·6) per cent, and significantly greater when the original axillary surgery was SNB compared with ALND (OR 2·97, 95 per cent c.i. 1·66 to 5·32). The rate of aberrant lymphatic drainage identification was 25·7 (23·0 to 28·3) per cent, and significantly greater when the original axillary surgery was ALND (OR 0·27, 0·19 to 0·38). The metastatic sentinel node rate was 10·4 (8·6 to 12·3) per cent, and a significantly greater metastatic nodal burden was identified in the ipsilateral axilla (OR 6·31, 1·03 to 38·79). Lymphatic mapping is feasible in recurrent breast cancer. It avoids ALND in over 50 per cent of patients who have undergone SNB, and allows the 4 per cent of patients with metastatically involved aberrant nodes to receive targeted surgical and adjuvant therapies. © 2016 BJS Society Ltd Published by John Wiley & Sons Ltd.
Multifunctional Polymer Microbubbles for Advanced Sentinel Lymph Node Imaging and Mapping
2012-06-01
of thiolated poly(acrylic acid) with fluorescein attached. (b) Bright field image of large bubbles stabilized by polymer and phospholipid...Page 1 of 6 AD_________________ Award Number: W81XWH-11-1-0215 TITLE: Multifunctional Polymer Microbubbles for Advanced... Polymer Microbubbles for Advanced Sentinel Lymph Node Imaging and Mapping 5b. GRANT NUMBER W81XWH-11-1-0215 5c. PROGRAM ELEMENT NUMBER 6
Monte Carlo simulation of photon migration in a cloud computing environment with MapReduce
Pratx, Guillem; Xing, Lei
2011-01-01
Monte Carlo simulation is considered the most reliable method for modeling photon migration in heterogeneous media. However, its widespread use is hindered by the high computational cost. The purpose of this work is to report on our implementation of a simple MapReduce method for performing fault-tolerant Monte Carlo computations in a massively-parallel cloud computing environment. We ported the MC321 Monte Carlo package to Hadoop, an open-source MapReduce framework. In this implementation, Map tasks compute photon histories in parallel while a Reduce task scores photon absorption. The distributed implementation was evaluated on a commercial compute cloud. The simulation time was found to be linearly dependent on the number of photons and inversely proportional to the number of nodes. For a cluster size of 240 nodes, the simulation of 100 billion photon histories took 22 min, a 1258 × speed-up compared to the single-threaded Monte Carlo program. The overall computational throughput was 85,178 photon histories per node per second, with a latency of 100 s. The distributed simulation produced the same output as the original implementation and was resilient to hardware failure: the correctness of the simulation was unaffected by the shutdown of 50% of the nodes. PMID:22191916
DOE Office of Scientific and Technical Information (OSTI.GOV)
Takao, Seishin, E-mail: takao@mech-me.eng.hokudai.ac.jp; Tadano, Shigeru; Taguchi, Hiroshi
2011-11-01
Purpose: To establish a method for the accurate acquisition and analysis of the variations in tumor volume, location, and three-dimensional (3D) shape of tumors during radiotherapy in the era of image-guided radiotherapy. Methods and Materials: Finite element models of lymph nodes were developed based on computed tomography (CT) images taken before the start of treatment and every week during the treatment period. A surface geometry map with a volumetric scale was adopted and used for the analysis. Six metastatic cervical lymph nodes, 3.5 to 55.1 cm{sup 3} before treatment, in 6 patients with head and neck carcinomas were analyzed inmore » this study. Three fiducial markers implanted in mouthpieces were used for the fusion of CT images. Changes in the location of the lymph nodes were measured on the basis of these fiducial markers. Results: The surface geometry maps showed convex regions in red and concave regions in blue to ensure that the characteristics of the 3D tumor geometries are simply understood visually. After the irradiation of 66 to 70 Gy in 2 Gy daily doses, the patterns of the colors had not changed significantly, and the maps before and during treatment were strongly correlated (average correlation coefficient was 0.808), suggesting that the tumors shrank uniformly, maintaining the original characteristics of the shapes in all 6 patients. The movement of the gravitational center of the lymph nodes during the treatment period was everywhere less than {+-}5 mm except in 1 patient, in whom the change reached nearly 10 mm. Conclusions: The surface geometry map was useful for an accurate evaluation of the changes in volume and 3D shapes of metastatic lymph nodes. The fusion of the initial and follow-up CT images based on fiducial markers enabled an analysis of changes in the location of the targets. Metastatic cervical lymph nodes in patients were suggested to decrease in size without significant changes in the 3D shape during radiotherapy. The movements of the gravitational center of the lymph nodes were almost all less than {+-}5 mm.« less
Resource utilization model for the algorithm to architecture mapping model
NASA Technical Reports Server (NTRS)
Stoughton, John W.; Patel, Rakesh R.
1993-01-01
The analytical model for resource utilization and the variable node time and conditional node model for the enhanced ATAMM model for a real-time data flow architecture are presented in this research. The Algorithm To Architecture Mapping Model, ATAMM, is a Petri net based graph theoretic model developed at Old Dominion University, and is capable of modeling the execution of large-grained algorithms on a real-time data flow architecture. Using the resource utilization model, the resource envelope may be obtained directly from a given graph and, consequently, the maximum number of required resources may be evaluated. The node timing diagram for one iteration period may be obtained using the analytical resource envelope. The variable node time model, which describes the change in resource requirement for the execution of an algorithm under node time variation, is useful to expand the applicability of the ATAMM model to heterogeneous architectures. The model also describes a method of detecting the presence of resource limited mode and its subsequent prevention. Graphs with conditional nodes are shown to be reduced to equivalent graphs with time varying nodes and, subsequently, may be analyzed using the variable node time model to determine resource requirements. Case studies are performed on three graphs for the illustration of applicability of the analytical theories.
EdgeMaps: visualizing explicit and implicit relations
NASA Astrophysics Data System (ADS)
Dörk, Marian; Carpendale, Sheelagh; Williamson, Carey
2011-01-01
In this work, we introduce EdgeMaps as a new method for integrating the visualization of explicit and implicit data relations. Explicit relations are specific connections between entities already present in a given dataset, while implicit relations are derived from multidimensional data based on shared properties and similarity measures. Many datasets include both types of relations, which are often difficult to represent together in information visualizations. Node-link diagrams typically focus on explicit data connections, while not incorporating implicit similarities between entities. Multi-dimensional scaling considers similarities between items, however, explicit links between nodes are not displayed. In contrast, EdgeMaps visualize both implicit and explicit relations by combining and complementing spatialization and graph drawing techniques. As a case study for this approach we chose a dataset of philosophers, their interests, influences, and birthdates. By introducing the limitation of activating only one node at a time, interesting visual patterns emerge that resemble the aesthetics of fireworks and waves. We argue that the interactive exploration of these patterns may allow the viewer to grasp the structure of a graph better than complex node-link visualizations.
Zhao, Xiaodong; Copeland, Daniel M.; Soares, Alexei S.; West, Ann H.
2008-01-01
Summary The crystal structure of the yeast SLN1 response regulator domain bound to both a phosphoryl analog (BeF3−) and Mg2+ ion in complex with its downstream phosphorelay signaling partner YPD1 has been determined at a resolution of 1.70 Å. Comparisons between the beryllium fluoride-activated complex and the unliganded (or apo) complex determined previously reveal modest but important differences. The SLN1-R1•Mg2+•BeF3− structure from the complex provides evidence for the first time that the mechanism of phosphorylation-induced activation is highly conserved between bacterial response regulator domains and this example from a eukaryotic organism. Residues in and around the active site undergo slight rearrangements in order to form bonds to the essential divalent cation and fluorine atoms of BeF3−. Two conserved switch-like residues (Thr 1173 and Phe 1192) occupy distinctly different positions in the apo- versus BeF3−-bound structures consistent with the “Y-T” coupling mechanism proposed for activation of CheY and other bacterial response regulators. Several loop regions and the α4-β5-α5 surface of the SLN1-R1 domain undergo subtle conformational changes (∼1-3 Å displacements relative to the apo-structure) that lead to significant changes in terms of contacts that are formed with YPD1. Detailed structural comparisons of protein-protein interactions in the apo- and BeF3−-bound complexes suggest at least a two-state equilibrium model for formation of a transient encounter complex, in which phosphorylation of the response regulator promotes the formation of a phosphotransfer-competent complex. In the BeF3−-activated complex, the position of His 64 from YPD1 is within ideal distance and near linear geometry with Asp 1144 from the SLN1-R1 domain for phosphotransfer to occur. The ground state structure presented here suggests that phosphoryl transfer will likely proceed through an associative mechanism involving formation of a pentacoordinate phosphorus intermediate. PMID:18076904
DOE Office of Scientific and Technical Information (OSTI.GOV)
Reed, Valerie K.; Cavalcanti, Jose L.; Strom, Eric A.
Purpose: To determine the anatomic distribution of gross supraclavicular nodes within the supraclavicular fossa using 2-deoxy-2-[F-18] fluoro-d-glucose (FDG) positron emission tomography/computed tomography (PET/CT) scans, and to evaluate likely coverage of specific regions of the supraclavicular fossa using standard radiation fields. Methods and Materials: We identified 33 patients with advanced or metastatic breast cancer who had a PET/CT scan demonstrating hypermetabolic supraclavicular lymph nodes in 2005. The locations of the involved lymph nodes were mapped onto a single CT set of images of the supraclavicular fossa. These lymph nodes were also mapped onto the treatment-planning CT dataset of 4 patients treatedmore » in our institution (2 patients with biopsy-proven supraclavicular nodes and 2 patients with clinically negative supraclavicular nodes). Results: We were able to determine the distribution of 52 supraclavicular lymph nodes in 32 patients. Of 32 patients, 28 (87%) had a history of metastatic disease, and 2 patients had isolated nodal recurrences. Five patients had supraclavicular nodes posterior to the vertebral body transverse process, and several lymph nodes were in close proximity to the medial field border, raising the possibility of geographic miss in these areas. Conclusions: In patients with locally advanced disease, increased coverage of the supraclavicular fossa medially and posteriorly may be warranted.« less
DING, Peng; FUNG, George Shiu-Kai; LIN, Ming De; HOLMAN, Shaina D.; GERMAN, Rebecca Z.
2015-01-01
Purpose To determine the effect of bilateral superior laryngeal nerve (SLN) lesion on swallowing threshold volume and the occurrence of aspiration, using a novel measurement technique for videofluorscopic swallowing studies (VFSS). Methods and Materials We used a novel radiographic phantom to assess volume of the milk containing barium from fluoroscopy. The custom made phantom was firstly calibrated by comparing image intensity of the phantom with known cylinder depths. Secondly, known volume pouches of milk in a pig cadaver were compared to volumes calculated with the phantom. Using these standards, we calculated the volume of milk in the valleculae, esophagus and larynx, for 205 feeding sequences from four infant pigs feeding before and after had bilateral SLN lesions. Swallow safety was assessed using the IMPAS scale. Results The log-linear correlation between image intensity values from the phantom filled with barium milk and the known phantom cylinder depths was strong (R2>0.95), as was the calculated volumes of the barium milk pouches. The threshold volume of bolus in the valleculae during feeding was significantly larger after bilateral SLN lesion than in control swallows (p<0.001). The IMPAS score increased in the lesioned swallows relative to the controls (p<0.001). Conclusion Bilateral SLN lesion dramatically increased the aspiration incidence and the threshold volume of bolus in valleculae. The use of this phantom permits quantification of the aspirated volume of fluid. The custom made phantom and calibration allow for more accurate 3D volume estimation from 2D x-ray in VFSS. PMID:25270532
Sentinel lymph node biopsy in clinically detected ductal carcinoma in situ.
Al-Ameer, Ahmed Yahia; Al Nefaie, Sahar; Al Johani, Badria; Anwar, Ihab; Al Tweigeri, Taher; Tulbah, Asma; Alshabanah, Mohmmed; Al Malik, Osama
2016-04-10
To study the indications for sentinel lymph node biopsy (SLNB) in clinically-detected ductal carcinoma in situ (CD-DCIS). A retrospective analysis of 20 patients with an initial diagnosis of pure DCIS by an image-guided core needle biopsy (CNB) between June 2006 and June 2012 was conducted at King Faisal Specialist Hospital. The accuracy of performing SLNB in CD-DCIS, the rate of sentinel and non-sentinel nodal metastasis, and the histologic underestimation rate of invasive cancer at initial diagnosis were analyzed. The inclusion criteria were a preoperative diagnosis of pure DCIS with no evidence of invasion. We excluded any patient with evidence of microinvasion or invasion. There were two cases of mammographically detected DCIS and 18 cases of CD-DCIS. All our patients were diagnosed by an image-guided CNB except two patients who were diagnosed by fine needle aspiration (FNA). All patients underwent breast surgery, SLNB, and axillary lymph node dissection (ALND) if the SLN was positive. Twenty patients with an initial diagnosis of pure DCIS underwent SLNB, 2 of whom had an ALND. The mean age of the patients was 49.7 years (range, 35-70). Twelve patients (60%) were premenopausal and 8 (40%) were postmenopausal. CNB was the diagnostic procedure for 18 patients, and 2 who were diagnosed by FNA were excluded from the calculation of the underestimation rate. Two out of 20 had a positive SLNB and underwent an ALND and neither had additional non sentinel lymph node metastasis. Both the sentinel visualization rate and the intraoperative sentinel identification rate were 100%. The false negative rate was 0%. Only 2 patients had a positive SLNB (10%) and neither had additional metastasis following an ALND. After definitive surgery, 3 patients were upstaged to invasive ductal carcinoma (3/18 = 16.6%) and 3 other patients were upstaged to DCIS with microinvasion (3/18 = 16.6%). Therefore the histologic underestimation rate of invasive disease was 33%. SLNB in CD-DCIS is technically feasible and highly accurate. We recommend limiting SLNB to patients undergoing a mastectomy.
Morais, Maurício; Subramanian, Suresh; Pandey, Usha; Samuel, Grace; Venkatesh, Meera; Martins, Manuel; Pereira, Sérgio; Correia, João D G; Santos, Isabel
2011-04-04
Despite being widely used in the clinical setting for sentinel lymph node detection (SLND), (99m)Tc-based colloids (e.g., (99m)Tc-human serum albumin colloids) present a set of properties that are far from ideal. Aiming to design novel compounds with improved biological properties, we describe herein the first class of fully characterized (99m)Tc(CO)₃-mannosylated dextran derivatives with adequate features for SLND. Dextran derivatives, containing the same number of pendant mannose units (13) and a variable number (n) of tridentate chelators (9, n = 1; 10, n = 4, 11, n= 12), have been synthesized and fully characterized. Radiolabeled polymers of the type fac-[(99m)Tc(CO)₃(k³-L)] (12, L = 9, 13, L = 10, 14, L = 11) have been obtained quantitatively in high radiochemical purity (≥ 98%) upon reaction of the dextran derivatives with fac-[(99m)Tc(CO)₃(H₂O)₃]+. The highly stable compounds 13 and 14 were identified by comparing their HPLC chromatograms with the ones obtained for the corresponding rhenium surrogates fac-[Re(CO)₃(k³-10)] (13a) and fac-[Re(CO)₃(k³-11)] (14a), which have been characterized both at the chemical (NMR and IR spectroscopy, and HPLC) and physical level (DLS, AFM and LDV). Compounds 13a and 14a present a positive zeta potential (+ 7.1 mV, pH 7.4) and a hydrodynamic diameter in the range 8.4-8.7 nm. Scintigraphic imaging and biodistribution studies in Wistar rats have shown good accumulation in the sentinel node at 60 min postinjection (6.71 ± 2.35%, 13; and 7.53 ± 0.69%, 14), with significant retention up to 180 min. A clear delineation of the sentinel lymph node without significant washout to other regions was observed in the scintigraphic images. The popliteal extraction of 94.47 ± 2.45% for 14 at 1 h postinjection, as compared to 61.81 ± 2.4% for 13, indicated that 14 is a very promising compound to be further explored as SLN imaging agent.
N-doped carbon nanodots for non-invasive photoacoustic imaging and photothermal therapy
NASA Astrophysics Data System (ADS)
Lee, Donghyun; Lee, Changho; Kwon, Woosung; Beack, Songeun; Kim, Chulhong
2017-03-01
We synthesized nitrogen-doped carbon nanodots (N-CNDs) for photoacoustic (PA) imaging and photothermal therapy (PTT) by controlling the nitrogen source and carbonizing organic acids. The N-CNDs showed strong optical absorbance in the near-infrared region, with great photostability and biodegradability. Thanks to the strong optical absorbance of NCNDs, the PA signals from N-CNDs were high enough to detect inside living animals and enabled minimally invasive PTT using N-CND. To evaluate the biodegradability and potential application of N-CNDs as a PA imaging contrast agent, we performed time-resolved PA imaging of sentinel lymph nodes (SLNs) and assessed renal clearance after hypodermic injection. SLN and vascular networks were photoacoustically visualized by an acoustic-resolution reflection-mode PA imaging system at a 680-nm optical wavelength. Furthermore, we performed whole-body PA imaging after subcutaneous injection of N-CNDs to assess their body distribution and clearance. Finally, we further investigated the use of N-CNDs for in vivo photothermal therapy in Balb/c nude xenograft HepG2-tumor model mice.
Guzman, Marco; Rubin, Adam; Cox, Paul; Landini, Fernando; Jackson-Menaldi, Cristina
2014-03-01
In this retrospective case study, we report the apparent clinical effectiveness of neuromuscular electrical stimulation (NMES) in combination with voice therapy (VT) for rehabilitating dysphonia secondary to suspected superior laryngeal nerve (SLN) weakness in two female patients. Both patients failed or plateaued with traditional VT but had significant improvement with the addition of NMES of the cricothyroid muscle and SLN using a VitalStim unit. Stimulation was provided simultaneously with voice exercises based on musical phonatory tasks. Both acoustic analysis and endoscopic evaluation demonstrated important improvements after treatment. In the first patient, the major change was obtained within the primo passaggio region; specifically, a decrease in voice breaks was demonstrated. In the second patient, an improvement in voice quality (less breathiness) and vocal range were the most important findings. Additionally, each patient reported a significant improvement in their voice complaints. Neuromuscular laryngeal electrical stimulation in combination with vocal exercises might be a useful tool to improve voice quality in patients with SLN injury. Copyright © 2014 The Voice Foundation. Published by Mosby, Inc. All rights reserved.
Method of and apparatus for modeling interactions
Budge, Kent G.
2004-01-13
A method and apparatus for modeling interactions can accurately model tribological and other properties and accommodate topological disruptions. Two portions of a problem space are represented, a first with a Lagrangian mesh and a second with an ALE mesh. The ALE and Lagrangian meshes are constructed so that each node on the surface of the Lagrangian mesh is in a known correspondence with adjacent nodes in the ALE mesh. The interaction can be predicted for a time interval. Material flow within the ALE mesh can accurately model complex interactions such as bifurcation. After prediction, nodes in the ALE mesh in correspondence with nodes on the surface of the Lagrangian mesh can be mapped so that they are once again adjacent to their corresponding Lagrangian mesh nodes. The ALE mesh can then be smoothed to reduce mesh distortion that might reduce the accuracy or efficiency of subsequent prediction steps. The process, from prediction through mapping and smoothing, can be repeated until a terminal condition is reached.
MROrchestrator: A Fine-Grained Resource Orchestration Framework for MapReduce Clusters
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sharma, Bikash; Prabhakar, Ramya; Kandemir, Mahmut
2012-01-01
Efficient resource management in data centers and clouds running large distributed data processing frameworks like MapReduce is crucial for enhancing the performance of hosted applications and boosting resource utilization. However, existing resource scheduling schemes in Hadoop MapReduce allocate resources at the granularity of fixed-size, static portions of nodes, called slots. In this work, we show that MapReduce jobs have widely varying demands for multiple resources, making the static and fixed-size slot-level resource allocation a poor choice both from the performance and resource utilization standpoints. Furthermore, lack of co-ordination in the management of mul- tiple resources across nodes prevents dynamic slotmore » reconfigura- tion, and leads to resource contention. Motivated by this, we propose MROrchestrator, a MapReduce resource Orchestrator framework, which can dynamically identify resource bottlenecks, and resolve them through fine-grained, co-ordinated, and on- demand resource allocations. We have implemented MROrches- trator on two 24-node native and virtualized Hadoop clusters. Experimental results with a suite of representative MapReduce benchmarks demonstrate up to 38% reduction in job completion times, and up to 25% increase in resource utilization. We further show how popular resource managers like NGM and Mesos when augmented with MROrchestrator can hike up their performance.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shih, Helen A.; Harisinghani, Mukesh; Zietman, Anthony L.
2005-11-15
Purpose: Toxicity from pelvic irradiation could be reduced if fields were limited to likely areas of nodal involvement rather than using the standard 'four-field box.' We employed a novel magnetic resonance lymphangiographic technique to highlight the likely sites of occult nodal metastasis from prostate cancer. Methods and Materials: Eighteen prostate cancer patients with pathologically confirmed node-positive disease had a total of 69 pathologic nodes identifiable by lymphotropic nanoparticle-enhanced MRI and semiquantitative nodal analysis. Fourteen of these nodes were in the para-aortic region, and 55 were in the pelvis. The position of each of these malignant nodes was mapped to amore » common template based on its relation to skeletal or vascular anatomy. Results: Relative to skeletal anatomy, nodes covered a diffuse volume from the mid lumbar spine to the superior pubic ramus and along the sacrum and pelvic side walls. In contrast, the nodal metastases mapped much more tightly relative to the large pelvic vessels. A proposed pelvic clinical target volume to encompass the region at greatest risk of containing occult nodal metastases would include a 2.0-cm radial expansion volume around the distal common iliac and proximal external and internal iliac vessels that would encompass 94.5% of the pelvic nodes at risk as defined by our node-positive prostate cancer patient cohort. Conclusions: Nodal metastases from prostate cancer are largely localized along the major pelvic vasculature. Defining nodal radiation treatment portals based on vascular rather than bony anatomy may allow for a significant decrease in normal pelvic tissue irradiation and its associated toxicities.« less
NASA Astrophysics Data System (ADS)
Xuan, Hejun; Wang, Yuping; Xu, Zhanqi; Hao, Shanshan; Wang, Xiaoli
2017-11-01
Virtualization technology can greatly improve the efficiency of the networks by allowing the virtual optical networks to share the resources of the physical networks. However, it will face some challenges, such as finding the efficient strategies for virtual nodes mapping, virtual links mapping and spectrum assignment. It is even more complex and challenging when the physical elastic optical networks using multi-core fibers. To tackle these challenges, we establish a constrained optimization model to determine the optimal schemes of optical network mapping, core allocation and spectrum assignment. To solve the model efficiently, tailor-made encoding scheme, crossover and mutation operators are designed. Based on these, an efficient genetic algorithm is proposed to obtain the optimal schemes of the virtual nodes mapping, virtual links mapping, core allocation. The simulation experiments are conducted on three widely used networks, and the experimental results show the effectiveness of the proposed model and algorithm.
Large-scale seismic waveform quality metric calculation using Hadoop
NASA Astrophysics Data System (ADS)
Magana-Zook, S.; Gaylord, J. M.; Knapp, D. R.; Dodge, D. A.; Ruppert, S. D.
2016-09-01
In this work we investigated the suitability of Hadoop MapReduce and Apache Spark for large-scale computation of seismic waveform quality metrics by comparing their performance with that of a traditional distributed implementation. The Incorporated Research Institutions for Seismology (IRIS) Data Management Center (DMC) provided 43 terabytes of broadband waveform data of which 5.1 TB of data were processed with the traditional architecture, and the full 43 TB were processed using MapReduce and Spark. Maximum performance of 0.56 terabytes per hour was achieved using all 5 nodes of the traditional implementation. We noted that I/O dominated processing, and that I/O performance was deteriorating with the addition of the 5th node. Data collected from this experiment provided the baseline against which the Hadoop results were compared. Next, we processed the full 43 TB dataset using both MapReduce and Apache Spark on our 18-node Hadoop cluster. These experiments were conducted multiple times with various subsets of the data so that we could build models to predict performance as a function of dataset size. We found that both MapReduce and Spark significantly outperformed the traditional reference implementation. At a dataset size of 5.1 terabytes, both Spark and MapReduce were about 15 times faster than the reference implementation. Furthermore, our performance models predict that for a dataset of 350 terabytes, Spark running on a 100-node cluster would be about 265 times faster than the reference implementation. We do not expect that the reference implementation deployed on a 100-node cluster would perform significantly better than on the 5-node cluster because the I/O performance cannot be made to scale. Finally, we note that although Big Data technologies clearly provide a way to process seismic waveform datasets in a high-performance and scalable manner, the technology is still rapidly changing, requires a high degree of investment in personnel, and will likely require significant changes in other parts of our infrastructure. Nevertheless, we anticipate that as the technology matures and third-party tool vendors make it easier to manage and operate clusters, Hadoop (or a successor) will play a large role in our seismic data processing.
Pervasive Radio Mapping of Industrial Environments Using a Virtual Reality Approach
Nedelcu, Adrian-Valentin; Machedon-Pisu, Mihai; Talaba, Doru
2015-01-01
Wireless communications in industrial environments are seriously affected by reliability and performance issues, due to the multipath nature of obstacles within such environments. Special attention needs to be given to planning a wireless industrial network, so as to find the optimum spatial position for each of the nodes within the network, and especially for key nodes such as gateways or cluster heads. The aim of this paper is to present a pervasive radio mapping system which captures (senses) data regarding the radio spectrum, using low-cost wireless sensor nodes. This data is the input of radio mapping algorithms that generate electromagnetic propagation profiles. Such profiles are used for identifying obstacles within the environment and optimum propagation pathways. With the purpose of further optimizing the radio planning process, the authors propose a novel human-network interaction (HNI) paradigm that uses 3D virtual environments in order to display the radio maps in a natural, easy-to-perceive manner. The results of this approach illustrate its added value to the field of radio resource planning of industrial communication systems. PMID:26167533
Pervasive Radio Mapping of Industrial Environments Using a Virtual Reality Approach.
Nedelcu, Adrian-Valentin; Machedon-Pisu, Mihai; Duguleana, Mihai; Talaba, Doru
2015-01-01
Wireless communications in industrial environments are seriously affected by reliability and performance issues, due to the multipath nature of obstacles within such environments. Special attention needs to be given to planning a wireless industrial network, so as to find the optimum spatial position for each of the nodes within the network, and especially for key nodes such as gateways or cluster heads. The aim of this paper is to present a pervasive radio mapping system which captures (senses) data regarding the radio spectrum, using low-cost wireless sensor nodes. This data is the input of radio mapping algorithms that generate electromagnetic propagation profiles. Such profiles are used for identifying obstacles within the environment and optimum propagation pathways. With the purpose of further optimizing the radio planning process, the authors propose a novel human-network interaction (HNI) paradigm that uses 3D virtual environments in order to display the radio maps in a natural, easy-to-perceive manner. The results of this approach illustrate its added value to the field of radio resource planning of industrial communication systems.
Sentinel lymph node biopsy from the vantage point of an oncologic surgeon.
Wilson, Lori L
2009-01-01
Sentinel lymph node biopsy has greatly influenced the surgical management of clinically localized primary melanoma. Lymphatic mapping and sentinel lymph node biopsy have been used for the selective management of the draining regional lymph node basin of primary cutaneous melanoma. Oncologic surgeons have adopted this procedure to selectively identify occult nodal status in melanoma patients who are at a higher risk of regional metastasis. The current standard of treatment of tumor-positive sentinel lymph node metastasis is immediate completion lymphadenectomy, but considerable debate surrounds the utility of this procedure. This contribution reviews development, technical aspects, selective management of the lymph node basin, and sentinel lymph node biopsy techniques.
Agarwal, Gaurav; Rajan, Sendhil; Mayilvaganan, Sabaretnam; Mishra, Anjali; Krishnani, Narendra; Gambhir, Sanjay
2018-05-01
The current standard-of-care for surgical staging of the axilla in clinically node-negative (N0) early breast cancers is sentinel lymph node biopsy (SLNB), which requires expensive radiopharmaceuticals for efficacious results. In-house produced low-cost radiopharmaceuticals may be the solution and have shown efficacy in earlier observational/pilot studies. We compared SLNB using in-house prepared radiopharmaceutical ( 99m Tc-Antimony-colloid) versus commercially marketed radiopharmaceutical ( 99m Tc-Sulphur-colloid) in this prospective randomized study. 78 clinically N0 early breast cancer patients (T1/2, N0 stages), undergoing primary surgery were prospectively randomized 1:1 into two groups; to receive SLNB using methylene blue, and either 99m Tc-Antimony colloid (Group-1) or 99m Tc-Sulphur colloid (Group-2). Completion axillary dissection was done in all (validation SLNB). SLNB indices were compared between the groups. The groups were comparable with regard to age, stage, tumour size, hormone receptors and HER2neu status. Cost of the in-house prepared 99m Tc-antimony colloid was 16-times lesser compared to 99m Tc-sulphur colloid. SLN identification rates (IR) in Groups 1 and 2 were 100 and 97.4% respectively, (p > 0.05). False negative rates (FNR) in Group 1 and 2 were 6.3% (1/16 patients) and 7.7% (1/13 patients), respectively, (p > 0.05). There were no major allergic reactions in either group. In this prospective randomized trial on early breast cancer patients, accuracy of SLNB was comparable using in-house prepared, 99m Tc-antimony colloid and commercially marketed 99m Tc-sulphur colloid as radiopharmaceutical, while 99m Tc-antimony colloid was much cheaper than 99m Tc-sulphur colloid.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Karakaya, Mahmut; Qi, Hairong
This paper addresses the communication and energy efficiency in collaborative visual sensor networks (VSNs) for people localization, a challenging computer vision problem of its own. We focus on the design of a light-weight and energy efficient solution where people are localized based on distributed camera nodes integrating the so-called certainty map generated at each node, that records the target non-existence information within the camera s field of view. We first present a dynamic itinerary for certainty map integration where not only each sensor node transmits a very limited amount of data but that a limited number of camera nodes ismore » involved. Then, we perform a comprehensive analytical study to evaluate communication and energy efficiency between different integration schemes, i.e., centralized and distributed integration. Based on results obtained from analytical study and real experiments, the distributed method shows effectiveness in detection accuracy as well as energy and bandwidth efficiency.« less
Som, Dipasree; Tak, Megha; Setia, Mohit; Patil, Asawari; Sengupta, Amit; Chilakapati, C Murali Krishna; Srivastava, Anurag; Parmar, Vani; Nair, Nita; Sarin, Rajiv; Badwe, R
2016-01-01
Raman spectroscopy which is based upon inelastic scattering of photons has a potential to emerge as a noninvasive bedside in vivo or ex vivo molecular diagnostic tool. There is a need to improve the sensitivity and predictability of Raman spectroscopy. We developed a grid matrix-based tissue mapping protocol to acquire cellular-specific spectra that also involved digital microscopy for localizing malignant and lymphocytic cells in sentinel lymph node biopsy sample. Biosignals acquired from specific cellular milieu were subjected to an advanced supervised analytical method, i.e., cross-correlation and peak-to-peak ratio in addition to PCA and PC-LDA. We observed decreased spectral intensity as well as shift in the spectral peaks of amides and lipid bands in the completely metastatic (cancer cells) lymph nodes with high cellular density. Spectral library of normal lymphocytes and metastatic cancer cells created using the cellular specific mapping technique can be utilized to create an automated smart diagnostic tool for bench side screening of sampled lymph nodes. Spectral library of normal lymphocytes and metastatic cancer cells created using the cellular specific mapping technique can be utilized to develop an automated smart diagnostic tool for bench side screening of sampled lymph nodes supported by ongoing global research in developing better technology and signal and big data processing algorithms.
Gonzales, Matthew J.; Sturgeon, Gregory; Segars, W. Paul; McCulloch, Andrew D.
2016-01-01
Cubic Hermite hexahedral finite element meshes have some well-known advantages over linear tetrahedral finite element meshes in biomechanical and anatomic modeling using isogeometric analysis. These include faster convergence rates as well as the ability to easily model rule-based anatomic features such as cardiac fiber directions. However, it is not possible to create closed complex objects with only regular nodes; these objects require the presence of extraordinary nodes (nodes with 3 or >= 5 adjacent elements in 2D) in the mesh. The presence of extraordinary nodes requires new constraints on the derivatives of adjacent elements to maintain continuity. We have developed a new method that uses an ensemble coordinate frame at the nodes and a local-to-global mapping to maintain continuity. In this paper, we make use of this mapping to create cubic Hermite models of the human ventricles and a four-chamber heart. We also extend the methods to the finite element equations to perform biomechanics simulations using these meshes. The new methods are validated using simple test models and applied to anatomically accurate ventricular meshes with valve annuli to simulate complete cardiac cycle simulations. PMID:27182096
Bhaskar, Kesavan; Anbu, Jayaraman; Ravichandiran, Velayutham; Venkateswarlu, Vobalaboina; Rao, Yamsani Madhusudan
2009-01-01
The aim of the study is to prepare aqueous dispersions of lipid nanoparticles – flurbiprofen solid lipid nanoparticles (FLUSLN) and flurbiprofen nanostructured lipid carriers (FLUNLC) by hot homogenization followed by sonication technique and then incorporated into the freshly prepared hydrogels for transdermal delivery. They are characterized for particle size, for all the formulations, more than 50% of the particles were below 300 nm after 90 days of storage at RT. DSC analyses were performed to characterize the state of drug and lipid modification. Shape and surface morphology were determined by TEM which revealed fairly spherical shape of the formulations. Further they were evaluated for in vitro drug release characteristics, rheological behaviour, pharmacokinetic and pharmacodynamic studies. The pharmacokinetics of flurbiprofen in rats following application of SLN gel (A1) and NLC gel (B1) for 24 h were evaluated. The Cmax of the B1 formulation was 38.67 ± 2.77 μg/ml, which was significantly higher than the A1 formulation (Cmax = 21.79 ± 2.96 μg/ml). The Cmax and AUC of the B1 formulation were 1.8 and 2.5 times higher than the A1 gel formulation respectively. The bioavailability of flurbiprofen with reference to oral administration was found to increase by 4.4 times when gel formulations were applied. Anti-inflammatory effect in the Carrageenan-induced paw edema in rat was significantly higher for B1 and A1 formulation than the orally administered flurbiprofen. Both the SLN and NLC dispersions and gels enriched with SLN and NLC possessed a sustained drug release over period of 24 h but the sustained effect was more pronounced with the SLN and NLC gel PMID:19243632
Distributed Sensor Fusion for Scalar Field Mapping Using Mobile Sensor Networks.
La, Hung Manh; Sheng, Weihua
2013-04-01
In this paper, autonomous mobile sensor networks are deployed to measure a scalar field and build its map. We develop a novel method for multiple mobile sensor nodes to build this map using noisy sensor measurements. Our method consists of two parts. First, we develop a distributed sensor fusion algorithm by integrating two different distributed consensus filters to achieve cooperative sensing among sensor nodes. This fusion algorithm has two phases. In the first phase, the weighted average consensus filter is developed, which allows each sensor node to find an estimate of the value of the scalar field at each time step. In the second phase, the average consensus filter is used to allow each sensor node to find a confidence of the estimate at each time step. The final estimate of the value of the scalar field is iteratively updated during the movement of the mobile sensors via weighted average. Second, we develop the distributed flocking-control algorithm to drive the mobile sensors to form a network and track the virtual leader moving along the field when only a small subset of the mobile sensors know the information of the leader. Experimental results are provided to demonstrate our proposed algorithms.
Motion planning with complete knowledge using a colored SOM.
Vleugels, J; Kok, J N; Overmars, M
1997-01-01
The motion planning problem requires that a collision-free path be determined for a robot moving amidst a fixed set of obstacles. Most neural network approaches to this problem are for the situation in which only local knowledge about the configuration space is available. The main goal of the paper is to show that neural networks are also suitable tools in situations with complete knowledge of the configuration space. In this paper we present an approach that combines a neural network and deterministic techniques. We define a colored version of Kohonen's self-organizing map that consists of two different classes of nodes. The network is presented with random configurations of the robot and, from this information, it constructs a road map of possible motions in the work space. The map is a growing network, and different nodes are used to approximate boundaries of obstacles and the Voronoi diagram of the obstacles, respectively. In a second phase, the positions of the two kinds of nodes are combined to obtain the road map. In this way a number of typical problems with small obstacles and passages are avoided, and the required number of nodes for a given accuracy is within reasonable limits. This road map is searched to find a motion connecting the given source and goal configurations of the robot. The algorithm is simple and general; the only specific computation that is required is a check for intersection of two polygons. We implemented the algorithm for planar robots allowing both translation and rotation and experiments show that compared to conventional techniques it performs well, even for difficult motion planning scenes.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jing, Hao; Wang, Shu-Lian, E-mail: wsl20040118@yahoo.com; Li, Jing
2015-10-01
Purpose: To map the location of metastatic supraclavicular (SCV) lymph nodes (LNMs) in breast cancer patients with SCV node involvement and determine whether and where the radiation therapy clinical target volume (CTV) of this region could be modified in high-risk subsets. Methods and Materials: Fifty-five patients with metastatic SCV LNMs were eligible for geographic mapping and atlas coverage analysis. All LNMs and their epicenters were registered proportionally by referencing the surrounding landmarks onto simulation computed tomography images of a standard patient. CTVs based on selected SCV atlases, including the one by the Radiation Therapy Oncology Group (RTOG) were contoured. Amore » modified SCV CTV was tried and shown to have better involved-node coverage and thus theoretically improved prophylaxis in this setting. Results: A total of 50 (91%) and 45 (81.8%) patients had LNMs in the medial and lateral SCV subregions, respectively. Also, 36 patients (65.5%) had LNMs located at the junction of the jugular-subclavian veins. All nodes were covered in only 25.5% to 41.8% of patients by different atlases. The RTOG atlas covered all nodes in 25.5% of patients. Stratified by the nodes in all the patients as a whole, 49.2% to 81.3% were covered, and the RTOG atlas covered 62.6%. The lateral and posterior borders were the most overlooked locations. Modification by extending the borders to natural anatomic barriers allowed the new CTV to cover all the nodes in 81.8% of patients and encompass 96.1% of all the nodes. Conclusions: According to the distribution of SCV LNMs, the extent of existing atlases might not be adequate for potential metastatic sites in certain groups of patients. The extension of the lateral and posterior CTV borders in high-risk or recurrent patients might be a reasonable approach for increasing coverage. However, additional data in more homogeneous populations with localized disease are needed before routine application.« less
Elze, J; Liebler-Tenorio, E; Ziller, M; Köhler, H
2013-07-01
The objective of this study was to identify the most reliable approach for prevalence estimation of Mycobacterium avium ssp. paratuberculosis (MAP) infection in clinically healthy slaughtered cattle. Sampling of macroscopically suspect tissue was compared to systematic sampling. Specimens of ileum, jejunum, mesenteric and caecal lymph nodes were examined for MAP infection using bacterial microscopy, culture, histopathology and immunohistochemistry. MAP was found most frequently in caecal lymph nodes, but sampling more tissues optimized the detection rate. Examination by culture was most efficient while combination with histopathology increased the detection rate slightly. MAP was detected in 49/50 animals with macroscopic lesions representing 1.35% of the slaughtered cattle examined. Of 150 systematically sampled macroscopically non-suspect cows, 28.7% were infected with MAP. This indicates that the majority of MAP-positive cattle are slaughtered without evidence of macroscopic lesions and before clinical signs occur. For reliable prevalence estimation of MAP infection in slaughtered cattle, systematic random sampling is essential.
NASA Astrophysics Data System (ADS)
2008-10-01
Based on bibliometric data from information-services provider Thomson Reuters, this map reveals "core areas" of physics, shown as coloured circular nodes, and the relationship between these subdisciplines, shown as lines.
Atkinson, Andrew J.; Logantha, Sunil Jit R. J.; Hao, Guoliang; Yanni, Joseph; Fedorenko, Olga; Sinha, Aditi; Gilbert, Stephen H.; Benson, Alan P.; Buckley, David L.; Anderson, Robert H.; Boyett, Mark R.; Dobrzynski, Halina
2013-01-01
Background The cardiac conduction system consists of the sinus node, nodal extensions, atrioventricular (AV) node, penetrating bundle, bundle branches, and Purkinje fibers. Node‐like AV ring tissue also exists at the AV junctions, and the right and left rings unite at the retroaortic node. The study aims were to (1) construct a 3‐dimensional anatomical model of the AV rings and retroaortic node, (2) map electrical activation in the right ring and study its action potential characteristics, and (3) examine gene expression in the right ring and retroaortic node. Methods and Results Three‐dimensional reconstruction (based on magnetic resonance imaging, histology, and immunohistochemistry) showed the extent and organization of the specialized tissues (eg, how the AV rings form the right and left nodal extensions into the AV node). Multiextracellular electrode array and microelectrode mapping of isolated right ring preparations revealed robust spontaneous activity with characteristic diastolic depolarization. Using laser microdissection gene expression measured at the mRNA level (using quantitative PCR) and protein level (using immunohistochemistry and Western blotting) showed that the right ring and retroaortic node, like the sinus node and AV node but, unlike ventricular muscle, had statistically significant higher expression of key transcription factors (including Tbx3, Msx2, and Id2) and ion channels (including HCN4, Cav3.1, Cav3.2, Kv1.5, SK1, Kir3.1, and Kir3.4) and lower expression of other key ion channels (Nav1.5 and Kir2.1). Conclusions The AV rings and retroaortic node possess gene expression profiles similar to that of the AV node. Ion channel expression and electrophysiological recordings show the AV rings could act as ectopic pacemakers and a source of atrial tachycardia. PMID:24356527
The Effectiveness of an Online Knowledge Map Instructional Presentation
ERIC Educational Resources Information Center
Foor, Jamie L.
2011-01-01
In this study, I investigated the effectiveness of the knowledge map (k-map) instructional strategy compared to a text-based presentation in an online environment. K-maps consist of node-link representations of concepts that together form the content of a topic or domain. The benefits of using k-maps are that concepts and ideas are represented as…
Sentinel Node Detection in Head and Neck Malignancies: Innovations in Radioguided Surgery
Vermeeren, L.; Klop, W. M. C.; van den Brekel, M. W. M.; Balm, A. J. M.; Nieweg, O. E.; Valdés Olmos, R. A.
2009-01-01
Sentinel node mapping is becoming a routine procedure for staging of various malignancies, because it can determine lymph node status more precisely. Due to anatomical problems, localizing sentinel nodes in the head and neck region on the basis of conventional images can be difficult. New diagnostic tools can provide better visualization of sentinel nodes. In an attempt to keep up with possible scientific progress, this article reviews new and innovative tools for sentinel node localization in this specific area. The overview comprises a short introduction of the sentinel node procedure as well as indications in the head and neck region. Then the results of SPECT/CT for sentinel node detection are described. Finally, a portable gamma camera to enable intraoperative real-time imaging with improved sentinel node detection is described. PMID:20016804
Sentinel Lymph Node Evaluation in Women with Cervical Cancer
Holman, Laura L.; Levenback, Charles F.; Frumovitz, Michael
2014-01-01
Lymph node status is the most important prognosticator of survival among women with early stage cervical cancer. This means that many cervical cancer patients will undergo pelvic lymphadenectomy as part of their treatment. Unfortunately, this procedure is associated with significant morbidity. Utilizing the sentinel lymph node technique for women with cervical cancer has the potential to decrease this morbidity. Multiple studies have suggested that sentinel lymph node mapping in these patients is feasible with excellent detection rates and sensitivity. This review examines the current body of literature regarding sentinel lymph node biopsy among women with cervical cancer. PMID:24407177
Centrally managed unified shared virtual address space
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wilkes, John
Systems, apparatuses, and methods for managing a unified shared virtual address space. A host may execute system software and manage a plurality of nodes coupled to the host. The host may send work tasks to the nodes, and for each node, the host may externally manage the node's view of the system's virtual address space. Each node may have a central processing unit (CPU) style memory management unit (MMU) with an internal translation lookaside buffer (TLB). In one embodiment, the host may be coupled to a given node via an input/output memory management unit (IOMMU) interface, where the IOMMU frontendmore » interface shares the TLB with the given node's MMU. In another embodiment, the host may control the given node's view of virtual address space via memory-mapped control registers.« less
Mapping edge-based traffic measurements onto the internal links in MPLS network
NASA Astrophysics Data System (ADS)
Zhao, Guofeng; Tang, Hong; Zhang, Yi
2004-09-01
Applying multi-protocol label switching techniques to IP-based backbone for traffic engineering goals has shown advantageous. Obtaining a volume of load on each internal link of the network is crucial for traffic engineering applying. Though collecting can be available for each link, such as applying traditional SNMP scheme, the approach may cause heavy processing load and sharply degrade the throughput of the core routers. Then monitoring merely at the edge of the network and mapping the measurements onto the core provides a good alternative way. In this paper, we explore a scheme for traffic mapping with edge-based measurements in MPLS network. It is supposed that the volume of traffic on each internal link over the domain would be mapped onto by measurements available only at ingress nodes. We apply path-based measurements at ingress nodes without enabling measurements in the core of the network. We propose a method that can infer a path from the ingress to the egress node using label distribution protocol without collecting routing data from core routers. Based on flow theory and queuing theory, we prove that our approach is effective and present the algorithm for traffic mapping. We also show performance simulation results that indicate potential of our approach.
Shah, Malay; Agrawal, Yadvendra
2013-01-01
The present paper describes an in silico solubility behavior of drug and lipids, an essential screening study in preparation of solid lipid nanoparticles (SLN). Ciprofloxacin HCl was selected as a model drug along with 11 lipids and 5 organic solvents. In silico miscibility study of drug/lipid/solvent was performed using Hansen solubility parameter approach calculated by group contribution method of Van Krevelen and Hoftyzer. Predicted solubility was validated by determining solubility of lipids in various solvent at different temperature range, while miscibility of drug in lipids was determined by apparent solubility study and partition experiment. The presence of oxygen and OH functionality increases the polarity and hydrogen bonding possibilities of the compound which has reflected the highest solubility parameter values for Geleol and Capmul MCM C8. Ethyl acetate, Geleol and Capmul MCM C8 was identified as suitable organic solvent, solid lipid and liquid lipid respectively based on a solubility parameter approach which was in agreement with the result of an apparent solubility study and partition coefficient. These works demonstrate the validity of solubility parameter approach and provide a feasible predictor to the rational selection of excipients in designing SLN formulation.
Zeltzer, Assaf A; Anzarut, Alexander; Braeckmans, Delphine; Seidenstuecker, Katrin; Hendrickx, Benoit; Van Hedent, Eddy; Hamdi, Moustapha
2017-09-01
A growing number of surgeons perform lymph node transfers for the treatment of lymphedema. When harvesting a vascularized lymph node groin flap (VGLNF) one of the major concerns is the potential risk of iatrogenic lymphedema of the donor-site. This article helps understanding of the lymph node distribution of the groin in order to minimize this risk. Fifty consecutive patients undergoing abdominal mapping by multi-detector CT scanner were included and 100 groins analyzed. The groin was divided in three zones (of which zone II is the safe zone) and lymph nodes were counted and mapped with their distances to anatomic landmarks. Further node units were plotted and counted. The average age was 48 years. A mean number of nodes of 6.5/groin was found. In zone II, which is our zone of interest a mean of 3.1 nodes were counted with a mean size of 7.8 mm. In three patients no nodes were found in zone II. In five patients nodes were seen in zone II but were not sufficient in size or number to be considered a lymph node unit. On average the lymph node unit in zone II was found to be 48.3 mm from the pubic tubercle when projected on a line from the pubic tubercle to the anterior superior iliac spine, 16.0 mm caudal to this line, and 20.4 mm above the groin crease. On average the lymph node unit was a mean of 41.7 mm lateral to the SCIV-SIEV confluence. This study provides increased understanding of the lymphatic anatomy in zone II of the groin flap and suggests a refined technique for designing the VGLNF. As with any flap there is a degree of individual patient variability. However, having information on the most common anatomy and flap design is of great value. © 2017 Wiley Periodicals, Inc.
Itazawa, Tomoko; Tamaki, Yukihisa; Komiyama, Takafumi; Nishimura, Yasumasa; Nakayama, Yuko; Ito, Hiroyuki; Ohde, Yasuhisa; Kusumoto, Masahiko; Sakai, Shuji; Suzuki, Kenji; Watanabe, Hirokazu; Asamura, Hisao
2017-01-01
The purpose of this study was to develop a consensus-based computed tomographic (CT) atlas that defines lymph node stations in radiotherapy for lung cancer based on the lymph node map of the International Association for the Study of Lung Cancer (IASLC). A project group in the Japanese Radiation Oncology Study Group (JROSG) initially prepared a draft of the atlas in which lymph node Stations 1–11 were illustrated on axial CT images. Subsequently, a joint committee of the Japan Lung Cancer Society (JLCS) and the Japanese Society for Radiation Oncology (JASTRO) was formulated to revise this draft. The committee consisted of four radiation oncologists, four thoracic surgeons and three thoracic radiologists. The draft prepared by the JROSG project group was intensively reviewed and discussed at four meetings of the committee over several months. Finally, we proposed definitions for the regional lymph node stations and the consensus-based CT atlas. This atlas was approved by the Board of Directors of JLCS and JASTRO. This resulted in the first official CT atlas for defining regional lymph node stations in radiotherapy for lung cancer authorized by the JLCS and JASTRO. In conclusion, the JLCS–JASTRO consensus-based CT atlas, which conforms to the IASLC lymph node map, was established. PMID:27609192
NASA Astrophysics Data System (ADS)
Meijs, M.; Debats, O.; Huisman, H.
2015-03-01
In prostate cancer, the detection of metastatic lymph nodes indicates progression from localized disease to metastasized cancer. The detection of positive lymph nodes is, however, a complex and time consuming task for experienced radiologists. Assistance of a two-stage Computer-Aided Detection (CAD) system in MR Lymphography (MRL) is not yet feasible due to the large number of false positives in the first stage of the system. By introducing a multi-structure, multi-atlas segmentation, using an affine transformation followed by a B-spline transformation for registration, the organ location is given by a mean density probability map. The atlas segmentation is semi-automatically drawn with ITK-SNAP, using Active Contour Segmentation. Each anatomic structure is identified by a label number. Registration is performed using Elastix, using Mutual Information and an Adaptive Stochastic Gradient optimization. The dataset consists of the MRL scans of ten patients, with lymph nodes manually annotated in consensus by two expert readers. The feature map of the CAD system consists of the Multi-Atlas and various other features (e.g. Normalized Intensity and multi-scale Blobness). The voxel-based Gentleboost classifier is evaluated using ROC analysis with cross validation. We show in a set of 10 studies that adding multi-structure, multi-atlas anatomical structure likelihood features improves the quality of the lymph node voxel likelihood map. Multiple structure anatomy maps may thus make MRL CAD more feasible.
A Structure-Adaptive Hybrid RBF-BP Classifier with an Optimized Learning Strategy
Wen, Hui; Xie, Weixin; Pei, Jihong
2016-01-01
This paper presents a structure-adaptive hybrid RBF-BP (SAHRBF-BP) classifier with an optimized learning strategy. SAHRBF-BP is composed of a structure-adaptive RBF network and a BP network of cascade, where the number of RBF hidden nodes is adjusted adaptively according to the distribution of sample space, the adaptive RBF network is used for nonlinear kernel mapping and the BP network is used for nonlinear classification. The optimized learning strategy is as follows: firstly, a potential function is introduced into training sample space to adaptively determine the number of initial RBF hidden nodes and node parameters, and a form of heterogeneous samples repulsive force is designed to further optimize each generated RBF hidden node parameters, the optimized structure-adaptive RBF network is used for adaptively nonlinear mapping the sample space; then, according to the number of adaptively generated RBF hidden nodes, the number of subsequent BP input nodes can be determined, and the overall SAHRBF-BP classifier is built up; finally, different training sample sets are used to train the BP network parameters in SAHRBF-BP. Compared with other algorithms applied to different data sets, experiments show the superiority of SAHRBF-BP. Especially on most low dimensional and large number of data sets, the classification performance of SAHRBF-BP outperforms other training SLFNs algorithms. PMID:27792737
Large-scale seismic waveform quality metric calculation using Hadoop
Magana-Zook, Steven; Gaylord, Jessie M.; Knapp, Douglas R.; ...
2016-05-27
Here in this work we investigated the suitability of Hadoop MapReduce and Apache Spark for large-scale computation of seismic waveform quality metrics by comparing their performance with that of a traditional distributed implementation. The Incorporated Research Institutions for Seismology (IRIS) Data Management Center (DMC) provided 43 terabytes of broadband waveform data of which 5.1 TB of data were processed with the traditional architecture, and the full 43 TB were processed using MapReduce and Spark. Maximum performance of ~0.56 terabytes per hour was achieved using all 5 nodes of the traditional implementation. We noted that I/O dominated processing, and that I/Omore » performance was deteriorating with the addition of the 5th node. Data collected from this experiment provided the baseline against which the Hadoop results were compared. Next, we processed the full 43 TB dataset using both MapReduce and Apache Spark on our 18-node Hadoop cluster. We conducted these experiments multiple times with various subsets of the data so that we could build models to predict performance as a function of dataset size. We found that both MapReduce and Spark significantly outperformed the traditional reference implementation. At a dataset size of 5.1 terabytes, both Spark and MapReduce were about 15 times faster than the reference implementation. Furthermore, our performance models predict that for a dataset of 350 terabytes, Spark running on a 100-node cluster would be about 265 times faster than the reference implementation. We do not expect that the reference implementation deployed on a 100-node cluster would perform significantly better than on the 5-node cluster because the I/O performance cannot be made to scale. Finally, we note that although Big Data technologies clearly provide a way to process seismic waveform datasets in a high-performance and scalable manner, the technology is still rapidly changing, requires a high degree of investment in personnel, and will likely require significant changes in other parts of our infrastructure. Nevertheless, we anticipate that as the technology matures and third-party tool vendors make it easier to manage and operate clusters, Hadoop (or a successor) will play a large role in our seismic data processing.« less
Large-scale seismic waveform quality metric calculation using Hadoop
DOE Office of Scientific and Technical Information (OSTI.GOV)
Magana-Zook, Steven; Gaylord, Jessie M.; Knapp, Douglas R.
Here in this work we investigated the suitability of Hadoop MapReduce and Apache Spark for large-scale computation of seismic waveform quality metrics by comparing their performance with that of a traditional distributed implementation. The Incorporated Research Institutions for Seismology (IRIS) Data Management Center (DMC) provided 43 terabytes of broadband waveform data of which 5.1 TB of data were processed with the traditional architecture, and the full 43 TB were processed using MapReduce and Spark. Maximum performance of ~0.56 terabytes per hour was achieved using all 5 nodes of the traditional implementation. We noted that I/O dominated processing, and that I/Omore » performance was deteriorating with the addition of the 5th node. Data collected from this experiment provided the baseline against which the Hadoop results were compared. Next, we processed the full 43 TB dataset using both MapReduce and Apache Spark on our 18-node Hadoop cluster. We conducted these experiments multiple times with various subsets of the data so that we could build models to predict performance as a function of dataset size. We found that both MapReduce and Spark significantly outperformed the traditional reference implementation. At a dataset size of 5.1 terabytes, both Spark and MapReduce were about 15 times faster than the reference implementation. Furthermore, our performance models predict that for a dataset of 350 terabytes, Spark running on a 100-node cluster would be about 265 times faster than the reference implementation. We do not expect that the reference implementation deployed on a 100-node cluster would perform significantly better than on the 5-node cluster because the I/O performance cannot be made to scale. Finally, we note that although Big Data technologies clearly provide a way to process seismic waveform datasets in a high-performance and scalable manner, the technology is still rapidly changing, requires a high degree of investment in personnel, and will likely require significant changes in other parts of our infrastructure. Nevertheless, we anticipate that as the technology matures and third-party tool vendors make it easier to manage and operate clusters, Hadoop (or a successor) will play a large role in our seismic data processing.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sreepathi, Sarat; D'Azevedo, Eduardo; Philip, Bobby
On large supercomputers, the job scheduling systems may assign a non-contiguous node allocation for user applications depending on available resources. With parallel applications using MPI (Message Passing Interface), the default process ordering does not take into account the actual physical node layout available to the application. This contributes to non-locality in terms of physical network topology and impacts communication performance of the application. In order to mitigate such performance penalties, this work describes techniques to identify suitable task mapping that takes the layout of the allocated nodes as well as the application's communication behavior into account. During the first phasemore » of this research, we instrumented and collected performance data to characterize communication behavior of critical US DOE (United States - Department of Energy) applications using an augmented version of the mpiP tool. Subsequently, we developed several reordering methods (spectral bisection, neighbor join tree etc.) to combine node layout and application communication data for optimized task placement. We developed a tool called mpiAproxy to facilitate detailed evaluation of the various reordering algorithms without requiring full application executions. This work presents a comprehensive performance evaluation (14,000 experiments) of the various task mapping techniques in lowering communication costs on Titan, the leadership class supercomputer at Oak Ridge National Laboratory.« less
Network of dedicated processors for finding lowest-cost map path
NASA Technical Reports Server (NTRS)
Eberhardt, Silvio P. (Inventor)
1991-01-01
A method and associated apparatus are disclosed for finding the lowest cost path of several variable paths. The paths are comprised of a plurality of linked cost-incurring areas existing between an origin point and a destination point. The method comprises the steps of connecting a purality of nodes together in the manner of the cost-incurring areas; programming each node to have a cost associated therewith corresponding to one of the cost-incurring areas; injecting a signal into one of the nodes representing the origin point; propagating the signal through the plurality of nodes from inputs to outputs; reducing the signal in magnitude at each node as a function of the respective cost of the node; and, starting at one of the nodes representing the destination point and following a path having the least reduction in magnitude of the signal from node to node back to one of the nodes representing the origin point whereby the lowest cost path from the origin point to the destination point is found.
Patterns of regional head and neck lymph node metastasis in primary conjunctival malignant melanoma
Lim, M; Tatla, T; Hersh, D; Hungerford, J
2006-01-01
Objective To correlate patterns of regional lymph node metastasis with the site of origin in primary conjunctival malignant melanoma. Design Retrospective analysis (1990–2003) of clinical data. Setting Two London tertiary referral centres. Participants 12 patients presenting with regional metastases after failed local treatment for conjunctival malignant melanoma. Results 6 cases predominantly involving the temporal conjunctiva metastasised to the pre‐auricular lymph nodes. Two cases predominantly involving the nasal conjunctiva metastasised to the submandibular nodes. Of the two cases with purely multifocal disease, one metastasised to the pre‐auricular nodes and another to both submandibular and parotid nodes. One primary conjunctival malignant melanoma had its origin in temporal conjunctiva but metastasised to submandibular nodes, and another case originating from nasal conjunctiva metastasised to pre‐auricular nodes. Conclusions Temporal conjunctival melanotic lesions tend to metastasise clinically to pre‐auricular lymph nodes and nasal conjunctival melanotic lesions metastasise to the submandibular lymph nodes. Patterns appear consistent with laboratory‐based anatomically mapped lymphatic drainage basins of the conjunctiva. PMID:16928703
Chandra, Piyush; Dhake, Sanket; Shah, Sneha; Agrawal, Archi; Purandare, Nilendu; Rangarajan, Venkatesh
2017-01-01
Evidence supporting the use of Sentinel node biopsy (SNB) for nodal staging of early oral squamous cell carcinomas (OSCC) appears to be very promising. Pre-operative lymphatic mapping using planar lymphoscinitigraphy (PL) with or without SPECT/CT in the SNB procedure is useful in sentinel node localization and for planning appropriate surgery. Recently, a large prospective multi-centric study evaluating SNB in cutaneous melanoma, breast and pelvic malignancies, demonstrated that adding SPECT to PL leads to surgical adjustments in a considerable number of patients. Our aim of this study was to evaluate the incremental value of additional SPECT/CT over PL alone in SNB for OSCC. This was a retrospective analysis of 44 patients (40- tongue, 4- buccal mucosa) with T1-T2, clinically N0 oral cavity SCC who underwent sentinel node biopsy procedure. PL and SPECT lymphoscinitigraphy images were compared for pre-operative mapping of sentinel nodes. Using a handheld gamma probe, a total of 179 sentinel nodes were harvested, with a mean of 4.06 per patient. PL revealed 75 hotspots with a mean of 1.70 per patient, and SPECT/CT revealed 92 hotspots with a mean of 2.09 per patient. Additional hotpots were identified in 14 patients on SPECT/CT, which included 4 patients, where PL did not detect any sentinel nodes. Pre-operative SPECT/CT in addition to planar lympho-scinitigraphy in sentinel node biopsies of oral cavity SCC detects more number of sentinel nodes compared to planar imaging alone. The higher sensitivity of SPECT combined with better anatomical localization using diagnostic CT may further improve the precision of SNB procedure.
Online Exhibits & Concept Maps
NASA Astrophysics Data System (ADS)
Douma, M.
2009-12-01
Presenting the complexity of geosciences to the public via the Internet poses a number of challenges. For example, utilizing various - and sometimes redundant - Web 2.0 tools can quickly devour limited time. Do you tweet? Do you write press releases? Do you create an exhibit or concept map? The presentation will provide participants with a context for utilizing Web 2.0 tools by briefly highlighting methods of online scientific communication across several dimensions. It will address issues of: * breadth and depth (e.g. from narrow topics to well-rounded views), * presentation methods (e.g. from text to multimedia, from momentary to enduring), * sources and audiences (e.g. for experts or for the public, content developed by producers to that developed by users), * content display (e.g. from linear to non-linear, from instructive to entertaining), * barriers to entry (e.g. from an incumbent advantage to neophyte accessible, from amateur to professional), * cost and reach (e.g. from cheap to expensive), and * impact (e.g. the amount learned, from anonymity to brand awareness). Against this backdrop, the presentation will provide an overview of two methods of online information dissemination, exhibits and concept maps, using the WebExhibits online museum (www.webexhibits.org) and SpicyNodes information visualization tool (www.spicynodes.org) as examples, with tips on how geoscientists can use either to communicate their science. Richly interactive online exhibits can serve to engage a large audience, appeal to visitors with multiple learning styles, prompt exploration and discovery, and present a topic’s breadth and depth. WebExhibits, which was among the first online museums, delivers interactive information, virtual experiments, and hands-on activities to the public. While large, multidisciplinary exhibits on topics like “Color Vision and Art” or “Calendars Through the Ages” require teams of scholars, user interface experts, professional writers and editors, teachers, artists, and web designers, a smaller scale collaborative effort can result in an effective mini-exhibit. Online concept maps can present a large quantity of information in bite-size chunks, demonstrating interrelationships between pieces of information without inundating visitors. SpicyNodes uses radial mapping technology to enable visitors to learn about a topic or search for information in intuitive and organic ways. This online concept mapping tool can be used as a portal to invite exploration into topics, or as a means of displaying hierarchies of information. With nodes that contain text, audio, video, and links, interactive online concept maps especially engage visual, kinesthetic, and nonlinear learners. SpicyNodes is also useful for scientists who wish to complement papers, chapters, and books with an online interface that is especially appealing to nonlinear learners. Essentially, SpicyNodes shifts the burden of discovery from the reader to the author. For example, the author may create a nodemap on climate change with hundreds of nodes, but as visitors drill through the nodemap for information (e.g. from climate change to atmospheric gases to carbon dioxide), they see only a few nodes at a time and are not overwhelmed.
Sun, Yao; Ding, Mingmin; Zeng, Xiaodong; Xiao, Yuling; Wu, Huaping; Zhou, Hui; Ding, Bingbing; Qu, Chunrong; Hou, Wei; Er-bu, AGA; Zhang, Yejun; Cheng, Zhen
2017-01-01
Though high brightness and biocompatible small NIR-II dyes are highly desirable in clinical or translational cancer research, their fluorescent cores are relatively limited and their synthetic processes are somewhat complicated. Herein, we have explored the design and synthesis of novel NIR-II fluorescent materials (H1) without tedious chromatographic isolation with improved fluorescence performance (QY ≈ 2%) by introducing 2-amino 9,9-dialkyl-substituted fluorene as a donor into the backbone. Several types of water-soluble and biocompatible NIR-II probes: SXH, SDH, and H1 NPs were constructed via different chemical strategies based on H1, and then their potential to be used in in vivo tumor imaging and image-guided surgery in the NIR-II region was explored. High levels of uptake were obtained for both passive and active tumor targeting probes SXH and SDH. Furthermore, high resolution imaging of blood vessels on tumors and the whole body of living mice using H1 NPs for the first time has demonstrated precise NIR-II image-guided sentinel lymph node (SLN) surgery. PMID:28507722
A Multi-Hop Clustering Mechanism for Scalable IoT Networks.
Sung, Yoonyoung; Lee, Sookyoung; Lee, Meejeong
2018-03-23
It is expected that up to 26 billion Internet of Things (IoT) equipped with sensors and wireless communication capabilities will be connected to the Internet by 2020 for various purposes. With a large scale IoT network, having each node connected to the Internet with an individual connection may face serious scalability issues. The scalability problem of the IoT network may be alleviated by grouping the nodes of the IoT network into clusters and having a representative node in each cluster connect to the Internet on behalf of the other nodes in the cluster instead of having a per-node Internet connection and communication. In this paper, we propose a multi-hop clustering mechanism for IoT networks to minimize the number of required Internet connections. Specifically, the objective of proposed mechanism is to select the minimum number of coordinators, which take the role of a representative node for the cluster, i.e., having the Internet connection on behalf of the rest of the nodes in the cluster and to map a partition of the IoT nodes onto the selected set of coordinators to minimize the total distance between the nodes and their respective coordinator under a certain constraint in terms of maximum hop count between the IoT nodes and their respective coordinator. Since this problem can be mapped into a set cover problem which is known as NP-hard, we pursue a heuristic approach to solve the problem and analyze the complexity of the proposed solution. Through a set of experiments with varying parameters, the proposed scheme shows 63-87.3% reduction of the Internet connections depending on the number of the IoT nodes while that of the optimal solution is 65.6-89.9% in a small scale network. Moreover, it is shown that the performance characteristics of the proposed mechanism coincide with expected performance characteristics of the optimal solution in a large-scale network.
A Multi-Hop Clustering Mechanism for Scalable IoT Networks
2018-01-01
It is expected that up to 26 billion Internet of Things (IoT) equipped with sensors and wireless communication capabilities will be connected to the Internet by 2020 for various purposes. With a large scale IoT network, having each node connected to the Internet with an individual connection may face serious scalability issues. The scalability problem of the IoT network may be alleviated by grouping the nodes of the IoT network into clusters and having a representative node in each cluster connect to the Internet on behalf of the other nodes in the cluster instead of having a per-node Internet connection and communication. In this paper, we propose a multi-hop clustering mechanism for IoT networks to minimize the number of required Internet connections. Specifically, the objective of proposed mechanism is to select the minimum number of coordinators, which take the role of a representative node for the cluster, i.e., having the Internet connection on behalf of the rest of the nodes in the cluster and to map a partition of the IoT nodes onto the selected set of coordinators to minimize the total distance between the nodes and their respective coordinator under a certain constraint in terms of maximum hop count between the IoT nodes and their respective coordinator. Since this problem can be mapped into a set cover problem which is known as NP-hard, we pursue a heuristic approach to solve the problem and analyze the complexity of the proposed solution. Through a set of experiments with varying parameters, the proposed scheme shows 63–87.3% reduction of the Internet connections depending on the number of the IoT nodes while that of the optimal solution is 65.6–89.9% in a small scale network. Moreover, it is shown that the performance characteristics of the proposed mechanism coincide with expected performance characteristics of the optimal solution in a large-scale network. PMID:29570691
Itazawa, Tomoko; Tamaki, Yukihisa; Komiyama, Takafumi; Nishimura, Yasumasa; Nakayama, Yuko; Ito, Hiroyuki; Ohde, Yasuhisa; Kusumoto, Masahiko; Sakai, Shuji; Suzuki, Kenji; Watanabe, Hirokazu; Asamura, Hisao
2017-01-01
The purpose of this study was to develop a consensus-based computed tomographic (CT) atlas that defines lymph node stations in radiotherapy for lung cancer based on the lymph node map of the International Association for the Study of Lung Cancer (IASLC). A project group in the Japanese Radiation Oncology Study Group (JROSG) initially prepared a draft of the atlas in which lymph node Stations 1-11 were illustrated on axial CT images. Subsequently, a joint committee of the Japan Lung Cancer Society (JLCS) and the Japanese Society for Radiation Oncology (JASTRO) was formulated to revise this draft. The committee consisted of four radiation oncologists, four thoracic surgeons and three thoracic radiologists. The draft prepared by the JROSG project group was intensively reviewed and discussed at four meetings of the committee over several months. Finally, we proposed definitions for the regional lymph node stations and the consensus-based CT atlas. This atlas was approved by the Board of Directors of JLCS and JASTRO. This resulted in the first official CT atlas for defining regional lymph node stations in radiotherapy for lung cancer authorized by the JLCS and JASTRO. In conclusion, the JLCS-JASTRO consensus-based CT atlas, which conforms to the IASLC lymph node map, was established. © The Author 2016. Published by Oxford University Press on behalf of The Japan Radiation Research Society and Japanese Society for Radiation Oncology.
Tsuji, Kojun; Tsujimura, Takanori; Magara, Jin; Sakai, Shogo; Nakamura, Yuki; Inoue, Makoto
2015-02-01
The aim of the present study was to investigate the adaptation of the swallowing reflex in terms of reduced swallowing reflex initiation following continuous superior laryngeal nerve stimulation. Forty-four male Sprague Dawley rats were anesthetized with urethane. To identify swallowing, electromyographic activity of the left mylohyoid and thyrohyoid muscles was recorded. To evoke the swallowing response, the superior laryngeal nerve (SLN), recurrent laryngeal nerve, or cortical swallowing area was electrically stimulated. Repetitive swallowing evoked by continuous SLN stimulation was gradually reduced, and this reduction was dependent on the resting time duration between stimulations. Prior SLN stimulation also suppressed subsequent swallowing initiation. The reduction in evoked swallows induced by recurrent laryngeal nerve or cortical swallowing area stimulation was less than that following superior laryngeal nerve stimulation. Decerebration had no effect on the reduction in evoked swallows. Prior subthreshold stimulation reduced subsequent initiation of swallowing, suggesting that there was no relationship between swallowing movement evoked by prior stimulation and the subsequent reduction in swallowing initiation. Overall, these data suggest that reduced sensory afferent nerve firing and/or trans-synaptic responses, as well as part of the brainstem central pattern generator, are involved in adaptation of the swallowing reflex following continuous stimulation of swallow-inducing peripheral nerves and cortical areas. Copyright © 2014 Elsevier Inc. All rights reserved.
Anatomy of hierarchy: Feedforward and feedback pathways in macaque visual cortex
Markov, Nikola T; Vezoli, Julien; Chameau, Pascal; Falchier, Arnaud; Quilodran, René; Huissoud, Cyril; Lamy, Camille; Misery, Pierre; Giroud, Pascale; Ullman, Shimon; Barone, Pascal; Dehay, Colette; Knoblauch, Kenneth; Kennedy, Henry
2013-01-01
The laminar location of the cell bodies and terminals of interareal connections determines the hierarchical structural organization of the cortex and has been intensively studied. However, we still have only a rudimentary understanding of the connectional principles of feedforward (FF) and feedback (FB) pathways. Quantitative analysis of retrograde tracers was used to extend the notion that the laminar distribution of neurons interconnecting visual areas provides an index of hierarchical distance (percentage of supragranular labeled neurons [SLN]). We show that: 1) SLN values constrain models of cortical hierarchy, revealing previously unsuspected areal relations; 2) SLN reflects the operation of a combinatorial distance rule acting differentially on sets of connections between areas; 3) Supragranular layers contain highly segregated bottom-up and top-down streams, both of which exhibit point-to-point connectivity. This contrasts with the infragranular layers, which contain diffuse bottom-up and top-down streams; 4) Cell filling of the parent neurons of FF and FB pathways provides further evidence of compartmentalization; 5) FF pathways have higher weights, cross fewer hierarchical levels, and are less numerous than FB pathways. Taken together, the present results suggest that cortical hierarchies are built from supra- and infragranular counterstreams. This compartmentalized dual counterstream organization allows point-to-point connectivity in both bottom-up and top-down directions. PMID:23983048
Khalil, Rawia M; Abd-Elbary, A; Kassem, Mahfoz A; Ghorab, Mamdouh M; Basha, Mona
2014-05-01
The aim of this study was to develop nanostructured lipid carriers (NLCs) as well as solid lipid nanoparticles (SLNs) and evaluate their potential in the topical delivery of meloxicam (MLX). The effect of various compositional variations on their physicochemical properties was investigated. Furthermore, MLX-loaded lipid nanoparticles-based hydrogels were formulated and the gels were evaluated as vehicles for topical application. The results showed that NLC and SLN dispersions had spherical shapes with an average size between 215 and 430 nm. High entrapment efficiency was obtained ranging from 61.94 to 90.38% with negatively charged zeta potential in the range of -19.1 to -25.7 mV. The release profiles of all formulations exhibited sustained release characteristics over 48 h and the release rates increased as the amount of liquid lipid in lipid core increased. Finally, Precirol NLC with 50% Miglyol® 812 and its corresponding SLN were incorporated in hydrogels. The gels showed adequate pH, non-Newtonian flow with shear-thinning behavior and controlled release profiles. The biological evaluation revealed that MLX-loaded NLC gel showed more pronounced effect compared to MLX-loaded SLN gel. It can be concluded that lipid nanoparticles represent promising particulate carriers for topical application.
Sesamol-loaded solid lipid nanoparticles for treatment of skin cancer.
Geetha, T; Kapila, Meenakshi; Prakash, Om; Deol, Parneet Kaur; Kakkar, Vandita; Kaur, Indu Pal
2015-02-01
Abstract Role of reactive oxygen species (ROS) in skin carcinogenesis is well documented. Natural molecules, like sesamol, with marked antioxidant potential can be useful in combating skin cancers. In vitro antiproliferative (using MTT assay) and DNA fragmentation studies in HL 60 cell lines, confirmed the apoptotic nature of sesamol. However, it showed a significant flux across the mice skin upon topical application, such that its local availability in skin is limited. Former is attributed mainly to its properties like small size, low molecular weight (138.28), and a sufficient lipid and water solubility (log P 1.29; solubility 38.8 mg/ml). To achieve its maximum epicutaneous delivery, packaging it into a suitable carrier system is thus indicated. Sesamol-loaded solid lipid nanoparticles (S-SLN) were thus prepared with particle size of 127.9 nm (PI: 0.256) and entrapment efficiency of 88.21%. Topical application of S-SLN in a cream base indicated significant retention in the skin with minimal flux across skin as confirmed by the in-vivo skin retention and ex-vivo skin permeation studies. In vivo anticancer studies performed on TPA-induced and benzo(a)pyrene initiated tumour production (ROS mediated) in mouse epidermis showed the normalization (in histology studies) of skin cancers post their induction, upon treatment with S-SLN.
Nooli, Mounika; Chella, Naveen; Kulhari, Hitesh; Shastri, Nalini R; Sistla, Ramakrishna
2017-04-01
Olmesartan medoxomil (OLM) is an antihypertensive drug with low oral bioavailability (28%) resulting from poor aqueous solubility, presystemic metabolism and P-glycoprotein mediated efflux. The present investigation studies the role of lipid nanocarriers in enhancing the OLM bioavailability through oral delivery. Solid lipid nanoparticles (SLN) were prepared by solvent emulsion-evaporation method. Statistical tools like regression analysis and Pareto charts were used to detect the important factors effecting the formulations. Formulation and process parameters were then optimized using mean effect plot and contour plots. The formulations were characterized for particle size, size distribution, surface charge, percentage of drug entrapped in nanoparticles, drug-excipients interactions, powder X-ray diffraction analysis and drug release in vitro. The optimized formulation comprised glyceryl monostearate, soya phosphatidylcholine and Tween 80 as lipid, co-emulsifier and surfactant, respectively, with an average particle size of 100 nm, PDI 0.291, zeta potential of -23.4 mV and 78% entrapment efficiency. Pharmacokinetic evaluation in male Sprague Dawley rats revealed 2.32-fold enhancement in relative bioavailability of drug from SLN when compared to that of OLM plain drug on oral administration. In conclusion, SLN show promising approaches as a vehicle for oral delivery of drugs like OLM.
Cationic solid lipid nanoparticles enhance ocular hypotensive effect of melatonin in rabbit.
Leonardi, Antonio; Bucolo, Claudio; Drago, Filippo; Salomone, Salvatore; Pignatello, Rosario
2015-01-15
The study was aimed at evaluating whether the ocular hypotensive effect of melatonin (MEL) was enhanced by its encapsulation in cationic solid lipid nanoparticles (cSLN), as well as at determining the tolerability of these formulations on the ocular surface. MEL was loaded in cSLN that had already been shown to be suitable for ophthalmic use. The formulations were prepared using Softisan(®) 100 as the main lipid matrix, with the presence of either stearic (SA) or palmitic acid (PA) as lipid modifiers. A fixed positive charge was provided by the addition of a cationic lipid (didecyldimethylammonium bromide). The ocular hypotensive effect was evaluated by measuring the intraocular pressure (IOP) during 24h in albino rabbits. MEL elicited a significant (p<0.01) IOP reduction in rabbit eye. All the formulations tested in vivo demonstrated a good tolerability. The nanocarrier containing SA was the most effective in terms of IOP reduction (maximum IOP reduction: -7 mmHg), and its effect lasted approximately 24h. The experimental data indicate that the new formulations based on cSLN loaded with MEL represent a potent anti-glaucoma treatment with a safe profile, warranting further clinical evaluation of the proposed nanotechnological strategy. Copyright © 2014. Published by Elsevier B.V.
GATE Monte Carlo simulation of dose distribution using MapReduce in a cloud computing environment.
Liu, Yangchuan; Tang, Yuguo; Gao, Xin
2017-12-01
The GATE Monte Carlo simulation platform has good application prospects of treatment planning and quality assurance. However, accurate dose calculation using GATE is time consuming. The purpose of this study is to implement a novel cloud computing method for accurate GATE Monte Carlo simulation of dose distribution using MapReduce. An Amazon Machine Image installed with Hadoop and GATE is created to set up Hadoop clusters on Amazon Elastic Compute Cloud (EC2). Macros, the input files for GATE, are split into a number of self-contained sub-macros. Through Hadoop Streaming, the sub-macros are executed by GATE in Map tasks and the sub-results are aggregated into final outputs in Reduce tasks. As an evaluation, GATE simulations were performed in a cubical water phantom for X-ray photons of 6 and 18 MeV. The parallel simulation on the cloud computing platform is as accurate as the single-threaded simulation on a local server and the simulation correctness is not affected by the failure of some worker nodes. The cloud-based simulation time is approximately inversely proportional to the number of worker nodes. For the simulation of 10 million photons on a cluster with 64 worker nodes, time decreases of 41× and 32× were achieved compared to the single worker node case and the single-threaded case, respectively. The test of Hadoop's fault tolerance showed that the simulation correctness was not affected by the failure of some worker nodes. The results verify that the proposed method provides a feasible cloud computing solution for GATE.
Lymphatic Territories (Lymphosomes) in the Rat: An Anatomical Study for Future Lymphatic Research.
Suami, Hiroo; Scaglioni, Mario F
2017-11-01
Understanding the precise anatomy in experimental animals is crucial for correct design of research projects. Rats are commonly used for scientific research in plastic surgery because of their availability in academic institutions, moderate cost, and sizable vessels for microsurgical procedures. In past publications about rat anatomy, lymphatic mapping has been limited and incomplete. The aim of this study was to comprehensively map the superficial lymphatic system in the rat. Twenty-seven Sprague-Dawley rats were used for this study. Indocyanine green fluorescence lymphography was used to identify the lymphatic vessels and lymph nodes. Under general anaesthesia, indocyanine green was injected intradermally at multiple spots along the dorsal and medial midlines, front and hind paws, ears, and tail. The course of the lymphatic vessels was traced on the skin with a marker pen and photographed. The superficial lymphatic vessels in each rat were sketched on a graphic template and all of the templates were superimposed using graphics software to define the relationship between the lymphatic vessel and sentinel node. Indocyanine green fluorescence lymphography was able to demonstrate the superficial lymphatic vessels in the rat. Six groups of regional lymph node/s were identified and lymphatic pathways to those nodes delineated. The authors' lymphosome concept was successfully applied to the rat, with six lymphosomes identified. The authors succeeded in performing superficial lymphatic mapping in the rat. The authors' anatomical findings can provide further information about the lymphatic system in the normal state and promote understanding of pathologic changes generated by surgical manipulation for future studies.
NASA Astrophysics Data System (ADS)
Felver, Bernhard; King, David C.; Lea, Simon C.; Price, Gareth J.; Walmsley, A. Damien
2008-06-01
Ultrasonic dental scalers are clinically used to remove deposits from tooth surfaces. A metal probe, oscillating at ultrasonic frequencies, is used to chip away deposits from the teeth. To reduce frictional heating, water flows over the operated probe in which a bi-product, cavitation, may be generated. The aim of this study is characterise probe oscillations using scanning laser vibrometry and to relate the recorded data to the occurrence of cavitation that is mapped in the course of this research. Scanning laser vibrometry (Polytec models 300-F/S and 400-3D) was used to measure the movement of various designs of operating probes and to locate vibration nodes / anti-nodes at different generator power settings and contact loads (100g and 200g). Cavitation mapping was performed by photographing the emission from a luminol solution with a digital camera (Artemis ICX285). The scaler design influences the number and location of vibration node / anti-node points. For all ultrasonic probes, the highest displacement amplitude values were recorded at the tip. The highest amounts of cavitation around the probes were recorded at the second anti-node measured from the tip. Broad, beaver-tale shaped probes produced more cavitation than slim shaped ones. The design also influences the amount of inertial cavitation around the operated instrument. The clinical relevance is that broad, beaver-tale shaped probes are unlikely to reach subgingival areas of the tooth. Further research is required to design probes that will be clinically superior to cleaning this area of the tooth.
Apaolaza, P S; Del Pozo-Rodríguez, A; Solinís, M A; Rodríguez, J M; Friedrich, U; Torrecilla, J; Weber, B H F; Rodríguez-Gascón, A
2016-06-01
X-linked juvenile retinoschisis (XLRS) is a retinal degenerative disorder caused by mutations in the RS1 gene encoding a protein termed retinoschisin. The disease is an excellent candidate for gene replacement therapy as the majority of mutations have been shown to lead to a complete deficiency of the secreted protein in the retinal structures. In this work, we have studied the ability of non-viral vectors based on solid lipid nanoparticles (SLN) to induce the expression of retinoschisin in photoreceptors (PR) after intravitreal administration to Rs1h-deficient mice. We designed two vectors prepared with SLN, protamine, and dextran (DX) or hyaluronic acid (HA), bearing a plasmid containing the human RS1 gene under the control of the murin opsin promoter (mOPS). In vitro, the nanocarriers were able to induce the expression of retinoschisin in a PR cell line. After injection into the murine vitreous, the formulation prepared with HA induced a higher transfection level in PR than the formulation prepared with DX. Moreover, the level of retinoschisin in the inner nuclear layer (INL), where bipolar cells are located, was also higher. Two weeks after vitreal administration into Rs1h-deficient mice, both formulations showed significant improvement of the retinal structure by inducing a decrease of cavities and PR loss, and an increase of retinal and outer nuclear layer (ONL) thickness. HA-SLN resulted in a significant higher increase in the thickness of both retina and ONL, which can be explained by the higher transfection level of PR. In conclusion, we have shown the structural improvement of the retina of Rs1h-deficient mice with PR specific expression of the RS1 gene driven by the specific promoter mOPS, after successful delivery via SLN-based non-viral vectors. Copyright © 2016 Elsevier Ltd. All rights reserved.