Sample records for noninvasive respiratory monitoring

  1. Respiratory Care year in review 2013: airway management, noninvasive monitoring, and invasive mechanical ventilation.

    PubMed

    Durbin, Charles G; Blanch, Lluís; Fan, Eddy; Hess, Dean R

    2014-04-01

    Fundamental to respiratory care practice are airway management, noninvasive monitoring, and invasive mechanical ventilation. The purpose of this paper is to review the recent literature related to these topics in a manner that is most likely to have interest to the readers of Respiratory Care.

  2. Smart Sensing Strip Using Monolithically Integrated Flexible Flow Sensor for Noninvasively Monitoring Respiratory Flow

    PubMed Central

    Jiang, Peng; Zhao, Shuai; Zhu, Rong

    2015-01-01

    This paper presents a smart sensing strip for noninvasively monitoring respiratory flow in real time. The monitoring system comprises a monolithically-integrated flexible hot-film flow sensor adhered on a molded flexible silicone case, where a miniaturized conditioning circuit with a Bluetooth4.0 LE module are packaged, and a personal mobile device that wirelessly acquires respiratory data transmitted from the flow sensor, executes extraction of vital signs, and performs medical diagnosis. The system serves as a wearable device to monitor comprehensive respiratory flow while avoiding use of uncomfortable nasal cannula. The respiratory sensor is a flexible flow sensor monolithically integrating four elements of a Wheatstone bridge on single chip, including a hot-film resistor, a temperature-compensating resistor, and two balancing resistors. The monitor takes merits of small size, light weight, easy operation, and low power consumption. Experiments were conducted to verify the feasibility and effectiveness of monitoring and diagnosing respiratory diseases using the proposed system. PMID:26694401

  3. State-of-the-Art Sensor Technology in Spain: Invasive and Non-Invasive Techniques for Monitoring Respiratory Variables

    PubMed Central

    Domingo, Christian; Blanch, Lluis; Murias, Gaston; Luján, Manel

    2010-01-01

    The interest in measuring physiological parameters (especially arterial blood gases) has grown progressively in parallel to the development of new technologies. Physiological parameters were first measured invasively and at discrete time points; however, it was clearly desirable to measure them continuously and non-invasively. The development of intensive care units promoted the use of ventilators via oral intubation ventilators via oral intubation and mechanical respiratory variables were progressively studied. Later, the knowledge gained in the hospital was applied to out-of-hospital management. In the present paper we review the invasive and non-invasive techniques for monitoring respiratory variables. PMID:22399898

  4. State-of-the-art sensor technology in Spain: invasive and non-invasive techniques for monitoring respiratory variables.

    PubMed

    Domingo, Christian; Blanch, Lluis; Murias, Gaston; Luján, Manel

    2010-01-01

    The interest in measuring physiological parameters (especially arterial blood gases) has grown progressively in parallel to the development of new technologies. Physiological parameters were first measured invasively and at discrete time points; however, it was clearly desirable to measure them continuously and non-invasively. The development of intensive care units promoted the use of ventilators via oral intubation ventilators via oral intubation and mechanical respiratory variables were progressively studied. Later, the knowledge gained in the hospital was applied to out-of-hospital management. In the present paper we review the invasive and non-invasive techniques for monitoring respiratory variables.

  5. Wireless non-invasive continuous respiratory monitoring with FMCW radar: a clinical validation study.

    PubMed

    van Loon, K; Breteler, M J M; van Wolfwinkel, L; Rheineck Leyssius, A T; Kossen, S; Kalkman, C J; van Zaane, B; Peelen, L M

    2016-12-01

    Altered respiratory rate is one of the first symptoms of medical conditions that require timely intervention, e.g., sepsis or opioid-induced respiratory depression. To facilitate continuous respiratory rate monitoring on general hospital wards a contactless, non-invasive, prototype monitor was developed using frequency modulated continuous wave radar. We aimed to study whether radar can reliably measure respiratory rate in postoperative patients. In a diagnostic cross-sectional study patients were monitored with the radar and the reference monitor (pneumotachograph during mechanical ventilation and capnography during spontaneous breathing). Eight patients were included; yielding 796 min of observation time during mechanical ventilation and 521 min during spontaneous breathing. After elimination of movement artifacts the bias and 95 % limits of agreement for mechanical ventilation and spontaneous breathing were -0.12 (-1.76 to 1.51) and -0.59 (-5.82 to 4.63) breaths per minute respectively. The radar was able to accurately measure respiratory rate in mechanically ventilated patients, but the accuracy decreased during spontaneous breathing.

  6. Noninvasive determination of anaerobic threshold by monitoring the %SpO2 changes and respiratory gas exchange.

    PubMed

    Nikooie, Roohollah; Gharakhanlo, Reza; Rajabi, Hamid; Bahraminegad, Morteza; Ghafari, Ali

    2009-10-01

    The purpose of this study was to determine the validity of noninvasive anaerobic threshold (AT) estimation using %SpO2 (arterial oxyhemoglobin saturation) changes and respiratory gas exchanges. Fifteen active, healthy males performed 2 graded exercise tests on a motor-driven treadmill in 2 separated sessions. Respiratory gas exchanges and heart rate (HR), lactate concentration, and %SpO2 were measured continuously throughout the test. Anaerobic threshold was determined based on blood lactate concentration (lactate-AT), %SpO2 changes (%SpO2-AT), respiratory exchange ratio (RER-AT), V-slope method (V-slope-AT), and ventilatory equivalent for O2 (EqO2-AT). Blood lactate measuring was considered as gold standard assessment of AT and was applied to confirm the validity of other noninvasive methods. The mean O2 corresponding to lactate-AT, %SpO2-AT, RER-AT, V-slope -AT, and EqO2-AT were 2176.6 +/- 206.4, 1909.5 +/- 221.4, 2141.2 +/- 245.6, 1933.7 +/- 216.4, and 1975 +/- 232.4, respectively. Intraclass correlation coefficient (ICC) analysis indicates a significant correlation between 4 noninvasive methods and the criterion method. Blond-Altman plots showed the good agreement between O2 corresponding to AT in each method and lactate-AT (95% confidence interval (CI). Our results indicate that a noninvasive and easy procedure of monitoring the %SpO2 is a valid method for estimation of AT. Also, in the present study, the respiratory exchange ratio (RER) method seemed to be the best respiratory index for noninvasive estimation of anaerobic threshold, and the heart rate corresponding to AT predicted by this method can be used by coaches and athletes to define training zones.

  7. Assessment of perioperative minute ventilation in obese versus non-obese patients with a non-invasive respiratory volume monitor.

    PubMed

    Mehta, Jaideep H; Cattano, Davide; Brayanov, Jordan B; George, Edward E

    2017-04-26

    Monitoring the adequacy of spontaneous breathing is a major patient safety concern in the post-operative setting. Monitoring is particularly important for obese patients, who are at a higher risk for post-surgical respiratory complications and often have increased metabolic demand due to excess weight. Here we used a novel, noninvasive Respiratory Volume Monitor (RVM) to monitor ventilation in both obese and non-obese orthopedic patients throughout their perioperative course, in order to develop better monitoring strategies. We collected respiratory data from 62 orthopedic patients undergoing elective joint replacement surgery under general anesthesia using a bio-impedance based RVM with an electrode PadSet placed on the thorax. Patients were stratified into obese (BMI ≥ 30) and non-obese cohorts and minute ventilation (MV) at various perioperative time points was compared against each patient's predicted minute ventilation (MV PRED ) based on ideal body weight (IBW) and body surface area (BSA). The distributions of MV measurements were also compared across obese and non-obese cohorts. Obese patients had higher MV than the non-obese patients before, during, and after surgery. Measured MV of obese patients was significantly higher than their MV PRED from IBW formulas, with BSA-based MV PRED being a closer estimate. Obese patients also had greater variability in MV post-operatively when treated with standard opioid dosing. Our study demonstrated that obese patients have greater variability in ventilation post-operatively when treated with standard opioid doses, and despite overall higher ventilation, many of them are still at risk for hypoventilation. BSA-based MV PRED formulas may be more appropriate than IBW-based ones when estimating the respiratory demand of obese patients. The RVM allows for the continuous and non-invasive assessment of respiratory function in both obese and non-obese patients.

  8. Application of digital signal processing methods for the diagnosis of respiration disorders during sleep with the use of plethysmographic wave analysis

    NASA Astrophysics Data System (ADS)

    Hatlinski, Grzegorz J.; Kornacki, Witold; Kukwa, Andrzej; Dobrowiecka, Bozena; Pikiel, Marek

    2004-07-01

    This paper proposes non-invasive solution to the problem of sleep apnea diagnosis especially in small children when sudden death syndrome is suspected. Plethysmographic wave analysis and digital signal processing algorithms are applied in order to find the effect invoked by respiratory movements of sleeping patients so as to diagnose the sleep apnea syndrome. The practical results of finding solution to problems mentioned above will be the possibility of algorithms implementation in a portable intelligent measurement system with a non-invasive monitoring of respiratory action. It works without any disturbances of sleep and respiratory movements especially in small children what could make possible in the future when continuous monitoring were applied to prevent sudden death syndrome occurrence.

  9. Evaluation of the Use of Capnography during the Transport of Critically Ill Mechanically Ventilated Patients.

    DTIC Science & Technology

    1992-12-15

    DISCUSSION: Gervais et a13 demonstrated that respiratory alkalosis developed when ICU patients were manually ventilated, without 7 spirometric...developed a respiratory acidosis. Use of the non-invasive monitor, the capnograph prevented this adverse effect and resulted in inIproved patient safety...ventilation, all patients developed respiratory acidoses. Capnography uniformly prevented the development of respiratory acidosis during transport. We

  10. Analysis of non-invasive FBG sensor for monitoring patient vital signs during MRI

    NASA Astrophysics Data System (ADS)

    Nedoma, Jan; Fajkus, Marcel; Martinek, Radek; Vasinek, Vladimir

    2017-10-01

    This article focuses on the analysis and verification of a non-invasive fiber Bragg grating (FBG) sensor used for the monitoring of a patient`s heart rate (HR) and respiratory rate (RR) in a magnetic resonance environment (MRI). Measuring heart and respiratory rate were carried out on a group of five volunteers with their written consent during MRI examinations. The type of the scanner used in the experiment was GE Signa HDxt 1.5T. The benefit of this article lies in the design of a sensor in the form of a sensor pad. The sensor is placed beneath a patient`s body lying supine. The purpose is to increase and improve the patient`s safety as well as to help doctors to predict panic and hyperventilation attacks of patients during MRI examinations. Provided Bland-Altman statistical analysis demonstrates the heart and respiratory rate detection with a satisfactory accuracy for all five volunteers.

  11. Development of an integrated sensor module for a non-invasive respiratory monitoring system

    NASA Astrophysics Data System (ADS)

    Kang, Seok-Won; Chang, Keun-Shik

    2013-09-01

    A respiratory monitoring system has been developed for analyzing the carbon dioxide (CO2) and oxygen (O2) concentrations in the expired air using gas sensors. The data can be used to estimate some medical conditions, including diffusion capability of the lung membrane, oxygen uptake, and carbon dioxide output. For this purpose, a 3-way valve derived from a servomotor was developed, which operates synchronously with human respiratory signals. In particular, the breath analysis system includes an integrated sensor module for valve control, data acquisition through the O2 and CO2 sensors, and respiratory rate monitoring, as well as software dedicated to analysis of respiratory gasses. In addition, an approximation technique for experimental data based on Haar-wavelet-based decomposition is explored to remove noise as well as to reduce the file size of data for long-term monitoring.

  12. Use of thoracic electrical impedance tomography as an auxiliary tool for alveolar recruitment maneuvers in acute respiratory distress syndrome: case report and brief literature review

    PubMed Central

    Rosa, Regis Goulart; Rutzen, William; Madeira, Laura; Ascoli, Aline Maria; Dexheimer Neto, Felippe Leopoldo; Maccari, Juçara Gasparetto; de Oliveira, Roselaine Pinheiro; Teixeira, Cassiano

    2015-01-01

    Thoracic electrical impedance tomography is a real-time, noninvasive monitoring tool of the regional pulmonary ventilation distribution. Its bedside use in patients with acute respiratory distress syndrome has the potential to aid in alveolar recruitment maneuvers, which are often necessary in cases of refractory hypoxemia. In this case report, we describe the monitoring results and interpretation of thoracic electrical impedance tomography used during alveolar recruitment maneuvers in a patient with acute respiratory distress syndrome, with transient application of high alveolar pressures and optimal positive end-expiratory pressure titration. Furthermore, we provide a brief literature review regarding the use of alveolar recruitment maneuvers and monitoring using thoracic electrical impedance tomography in patients with acute respiratory distress syndrome. PMID:26761481

  13. Polysomnography versus limited respiratory monitoring and nurse-led titration to optimise non-invasive ventilation set-up: a pilot randomised clinical trial.

    PubMed

    Patout, Maxime; Arbane, Gill; Cuvelier, Antoine; Muir, Jean Francois; Hart, Nicholas; Murphy, Patrick Brian

    2018-03-30

    Polysomnography (PSG) is recommended for non-invasive ventilation (NIV) set-up in patients with chronic respiratory failure. In this pilot randomised clinical trial, we compared the physiological effectiveness of NIV set-up guided by PSG to limited respiratory monitoring (LRM) and nurse-led titration in patients with COPD-obstructive sleep apnoea (OSA) overlap. The principal outcome of interest was change in daytime arterial partial pressure of carbon dioxide (PaCO 2 ) at 3 months. Fourteen patients with daytime PaCO 2 >6 kPa and body mass index >30 kg/m 2 were recruited. At 3 months, PaCO 2 was reduced by -0.88 kPa (95% CI -1.52 to -0.24 kPa) in the LRM group and by -0.36 kPa (95% CI -0.96 to 0.24 kPa) in the PSG group. These pilot data provide support to undertake a clinical trial investigating the clinical effectiveness of attended limited respiratory monitoring and PSG to establish NIV in patients with COPD-OSA overlap. Results, NCT02444806. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  14. [Meta-analyses on measurement precision of non-invasive hemodynamic monitoring technologies in adults].

    PubMed

    Pestel, G; Fukui, K; Higashi, M; Schmidtmann, I; Werner, C

    2018-06-01

    An ideal non-invasive monitoring system should provide accurate and reproducible measurements of clinically relevant variables that enables clinicians to guide therapy accordingly. The monitor should be rapid, easy to use, readily available at the bedside, operator-independent, cost-effective and should have a minimal risk and side effect profile for patients. An example is the introduction of pulse oximetry, which has become established for non-invasive monitoring of oxygenation worldwide. A corresponding non-invasive monitoring of hemodynamics and perfusion could optimize the anesthesiological treatment to the needs in individual cases. In recent years several non-invasive technologies to monitor hemodynamics in the perioperative setting have been introduced: suprasternal Doppler ultrasound, modified windkessel function, pulse wave transit time, radial artery tonometry, thoracic bioimpedance, endotracheal bioimpedance, bioreactance, and partial CO 2 rebreathing have been tested for monitoring cardiac output or stroke volume. The photoelectric finger blood volume clamp technique and respiratory variation of the plethysmography curve have been assessed for monitoring fluid responsiveness. In this manuscript meta-analyses of non-invasive monitoring technologies were performed when non-invasive monitoring technology and reference technology were comparable. The primary evaluation criterion for all studies screened was a Bland-Altman analysis. Experimental and pediatric studies were excluded, as were all studies without a non-invasive monitoring technique or studies without evaluation of cardiac output/stroke volume or fluid responsiveness. Most studies found an acceptable bias with wide limits of agreement. Thus, most non-invasive hemodynamic monitoring technologies cannot be considered to be equivalent to the respective reference method. Studies testing the impact of non-invasive hemodynamic monitoring technologies as a trend evaluation on outcome, as well as studies evaluating alternatives to the finger for capturing the raw signals for hemodynamic assessment, and, finally, studies evaluating technologies based on a flow time measurement are current topics of clinical research.

  15. Low minute ventilation episodes during anesthesia recovery following intraperitoneal surgery as detected by a non-invasive respiratory volume monitor.

    PubMed

    Cavalcante, Alexandre N; Martin, Yvette N; Sprung, Juraj; Imsirovic, Jasmin; Weingarten, Toby N

    2017-12-20

    An electrical impedance-based noninvasive respiratory volume monitor (RVM) accurately reports minute volume, tidal volume and respiratory rate. Here we used the RVM to quantify the occurrence of and evaluate the ability of clinical factors to predict respiratory depression in the post-anesthesia care unit (PACU). RVM generated respiratory data were collected from spontaneously breathing patients following intraperitoneal surgeries under general anesthesia admitted to the PACU. Respiratory depression was defined as low minute ventilation episode (LMVe, < 40% predicted minute ventilation for at least 2 min). We evaluated for associations between clinical variables including minute ventilation prior to opioid administration and LMVe following the first PACU administration of opioid. Also assessed was a low respiratory rate (< 8 breaths per minute) as a proxy for LMVe. Of 107 patients, 38 (36%) had LMVe. Affected patients had greater intraoperative opioid dose, P = 0.05. PACU opioids were administered to 45 (42.1%) subjects, of which 27 (25.2%) had LMVe (P = 0.42) within 30 min following opioid. Pre-opioid minute ventilation < 70% of predicted normal value was associated with LMVe, P < 0.01, (sensitivity = 100%, specificity = 81%).Low respiratory rate was a poor predictor of LMVe (sensitivity = 11.8%). Other clinical variables (e.g., obstructive sleep apnea) were not found to be predictors of LMVe. Using RVM we identified that mild, clinically nondetectable, respiratory depression prior to opioid administration in the PACU was associated with the development of substantial subsequent respiratory depression during the PACU stay.

  16. Noninvasive ventilation for patients with acute lung injury or acute respiratory distress syndrome.

    PubMed

    Nava, Stefano; Schreiber, Ania; Domenighetti, Guido

    2011-10-01

    Few studies have been performed on noninvasive ventilation (NIV) to treat hypoxic acute respiratory failure in patients with acute lung injury (ALI) or acute respiratory distress syndrome (ARDS). The outcomes of these patients, for whom endotracheal intubation is not mandatory, depend on the degree of hypoxia, the presence of comorbidities and complications, and their illness severity. The use of NIV as an alternative to invasive ventilation in severely hypoxemic patients with ARDS (ie, P(aO(2))/F(IO(2)) < 200) is not generally advisable and should be limited to hemodynamically stable patients who can be closely monitored in an intensive care unit by highly skilled staff. Early NIV application may be extremely helpful in immunocompromised patients with pulmonary infiltrates, in whom intubation dramatically increases the risk of infection, pneumonia, and death. The use of NIV in patients with severe acute respiratory syndrome and other airborne diseases has generated debate, despite encouraging clinical results, mainly because of safety issues. Overall, the high rate of NIV failure suggests a cautious approach to NIV use in patients with ALI/ARDS, including early initiation, intensive monitoring, and prompt intubation if signs of NIV failure emerge.

  17. [Role of noninvasive mechanical ventilation in patients with severe avian influenza A (H7N9) complicated with acute respiratory distress syndrome].

    PubMed

    Luo, Haili; Wang, Shaohong; Shen, Feng; Yuan, Tongmei; Pan, Xianguo; Liu, Jingtao; Yao, Ling; Wu, Juncheng; Long, Xuemei

    2018-05-01

    Human infection with avian influenza A (H7N9) is an acute contagious respiratory disease. Acute respiratory distress syndrome (ARDS) is a common complication in patients with severe avian influenza A (H7N9), for whom mechanical ventilation (MV) is an important supportive method. A patient, suffered from severe avian influenza A (H7N9) and complicated with ARDS, was admitted to the Second Affiliated Hospital of Guizhou Medical University in January 2017. With very intensive care for oxygenation, respiration and consciousness, and monitoring, she was successfully cured by comprehensive managements, among which noninvasive mechanical ventilation (NIV) was the major respiratory support method. The result demonstrate that, in patients with conscious state, satisfied expectoration ability and relatively good cooperation, and with close observation of oxygenation and respiratory rate, NIV may be accepted as an effective method for patient with ARDS caused by severe avian influenza A (H7N9).

  18. Verification and compensation of respiratory motion using an ultrasound imaging system.

    PubMed

    Chuang, Ho-Chiao; Hsu, Hsiao-Yu; Chiu, Wei-Hung; Tien, Der-Chi; Wu, Ren-Hong; Hsu, Chung-Hsien

    2015-03-01

    The purpose of this study was to determine if it is feasible to use ultrasound imaging as an aid for moving the treatment couch during diagnosis and treatment procedures associated with radiation therapy, in order to offset organ displacement caused by respiratory motion. A noninvasive ultrasound system was used to replace the C-arm device during diagnosis and treatment with the aims of reducing the x-ray radiation dose on the human body while simultaneously being able to monitor organ displacements. This study used a proposed respiratory compensating system combined with an ultrasound imaging system to monitor the compensation effect of respiratory motion. The accuracy of the compensation effect was verified by fluoroscopy, which means that fluoroscopy could be replaced so as to reduce unnecessary radiation dose on patients. A respiratory simulation system was used to simulate the respiratory motion of the human abdomen and a strain gauge (respiratory signal acquisition device) was used to capture the simulated respiratory signals. The target displacements could be detected by an ultrasound probe and used as a reference for adjusting the gain value of the respiratory signal used by the respiratory compensating system. This ensured that the amplitude of the respiratory compensation signal was a faithful representation of the target displacement. The results show that performing respiratory compensation with the assistance of the ultrasound images reduced the compensation error of the respiratory compensating system to 0.81-2.92 mm, both for sine-wave input signals with amplitudes of 5, 10, and 15 mm, and human respiratory signals; this represented compensation of the respiratory motion by up to 92.48%. In addition, the respiratory signals of 10 patients were captured in clinical trials, while their diaphragm displacements were observed simultaneously using ultrasound. Using the respiratory compensating system to offset, the diaphragm displacement resulted in compensation rates of 60%-84.4%. This study has shown that a respiratory compensating system combined with noninvasive ultrasound can provide real-time compensation of the respiratory motion of patients.

  19. Automated determination of wakefulness and sleep in rats based on non-invasively acquired measures of movement and respiratory activity

    PubMed Central

    Zeng, Tao; Mott, Christopher; Mollicone, Daniel; Sanford, Larry D.

    2012-01-01

    The current standard for monitoring sleep in rats requires labor intensive surgical procedures and the implantation of chronic electrodes which have the potential to impact behavior and sleep. With the goal of developing a non-invasive method to determine sleep and wakefulness, we constructed a non-contact monitoring system to measure movement and respiratory activity using signals acquired with pulse Doppler radar and from digitized video analysis. A set of 23 frequency and time-domain features were derived from these signals and were calculated in 10 s epochs. Based on these features, a classification method for automated scoring of wakefulness, non-rapid eye movement sleep (NREM) and REM in rats was developed using a support vector machine (SVM). We then assessed the utility of the automated scoring system in discriminating wakefulness and sleep by comparing the results to standard scoring of wakefulness and sleep based on concurrently recorded EEG and EMG. Agreement between SVM automated scoring based on selected features and visual scores based on EEG and EMG were approximately 91% for wakefulness, 84% for NREM and 70% for REM. The results indicate that automated scoring based on non-invasively acquired movement and respiratory activity will be useful for studies requiring discrimination of wakefulness and sleep. However, additional information or signals will be needed to improve discrimination of NREM and REM episodes within sleep. PMID:22178621

  20. Noninvasive health condition monitoring device for workers at high altitudes conditions.

    PubMed

    Aqueveque, Pablo; Gutierrez, Cristopher; Saavedra, Francisco; Pino, Esteban J

    2016-08-01

    This work presents the design and implementation of a continuous monitoring device to control the health state of workers, for instance miners, at high altitudes. The extreme ambient conditions are harmful for peoples' health; therefore a continuous control of the workers' vital signs is necessary. The developed system includes physiological variables: electrocardiogram (ECG), respiratory activity and body temperature (BT), and ambient variables: ambient temperature (AT) and relative humidity (RH). The noninvasive sensors are incorporated in a t-shirt to deliver a functional device, and maximum comfort to the users. The device is able to continuously calculate heart rate (HR) and respiration rate (RR), and establish a wireless data transmission to a central monitoring station.

  1. Near-infrared spectroscopic monitoring during cardiopulmonary exercise testing detects anaerobic threshold.

    PubMed

    Rao, Rohit P; Danduran, Michael J; Loomba, Rohit S; Dixon, Jennifer E; Hoffman, George M

    2012-06-01

    Cardiopulmonary exercise testing (CPET) provides assessment of the integrative responses involving the pulmonary, cardiovascular, and skeletal muscle systems. Application of exercise testing remains limited to children who are able to understand and cooperate with the exercise protocol. Near-infrared spectroscopy (NIRS) provides a noninvasive, continuous method to monitor regional tissue oxygenation (rSO2). Our specific aim was to predict anaerobic threshold (AT) during CPET noninvasively using two-site NIRS monitoring. Achievement of a practical noninvasive technology for estimating AT will increase the compatibility of CPET. Patients without structural or acquired heart disease were eligible for inclusion if they were ordered to undergo CPET by a cardiologist. Data from 51 subjects was analyzed. The ventilatory anaerobic threshold (VAT) was computed on [Formula: see text] and respiratory quotient post hoc using the standard V-slope method. The inflection points of the regional rSO2 time-series were identified as the noninvasive regional NIRS AT for each of the two monitored regions (cerebral and kidney). AT calculation made using an average of kidney and brain NIRS matched the calculation made by VAT for the same patient. Two-site NIRS monitoring of visceral organs is a predictor of AT.

  2. Using Supervised Machine Learning to Classify Real Alerts and Artifact in Online Multisignal Vital Sign Monitoring Data.

    PubMed

    Chen, Lujie; Dubrawski, Artur; Wang, Donghan; Fiterau, Madalina; Guillame-Bert, Mathieu; Bose, Eliezer; Kaynar, Ata M; Wallace, David J; Guttendorf, Jane; Clermont, Gilles; Pinsky, Michael R; Hravnak, Marilyn

    2016-07-01

    The use of machine-learning algorithms to classify alerts as real or artifacts in online noninvasive vital sign data streams to reduce alarm fatigue and missed true instability. Observational cohort study. Twenty-four-bed trauma step-down unit. Two thousand one hundred fifty-three patients. Noninvasive vital sign monitoring data (heart rate, respiratory rate, peripheral oximetry) recorded on all admissions at 1/20 Hz, and noninvasive blood pressure less frequently, and partitioned data into training/validation (294 admissions; 22,980 monitoring hours) and test sets (2,057 admissions; 156,177 monitoring hours). Alerts were vital sign deviations beyond stability thresholds. A four-member expert committee annotated a subset of alerts (576 in training/validation set, 397 in test set) as real or artifact selected by active learning, upon which we trained machine-learning algorithms. The best model was evaluated on test set alerts to enact online alert classification over time. The Random Forest model discriminated between real and artifact as the alerts evolved online in the test set with area under the curve performance of 0.79 (95% CI, 0.67-0.93) for peripheral oximetry at the instant the vital sign first crossed threshold and increased to 0.87 (95% CI, 0.71-0.95) at 3 minutes into the alerting period. Blood pressure area under the curve started at 0.77 (95% CI, 0.64-0.95) and increased to 0.87 (95% CI, 0.71-0.98), whereas respiratory rate area under the curve started at 0.85 (95% CI, 0.77-0.95) and increased to 0.97 (95% CI, 0.94-1.00). Heart rate alerts were too few for model development. Machine-learning models can discern clinically relevant peripheral oximetry, blood pressure, and respiratory rate alerts from artifacts in an online monitoring dataset (area under the curve > 0.87).

  3. Respiratory High-Dependency Care Units for the burden of acute respiratory failure.

    PubMed

    Scala, Raffaele

    2012-06-01

    The burden of acute respiratory failure (ARF) has become one of the greatest epidemiological challenges for the modern health systems. Consistently, the imbalance between the increasing prevalence of acutely de-compensated respiratory diseases and the shortage of high-daily cost ICU beds has stimulated new health cost-effective solutions. Respiratory High-Dependency Care Units (RHDCU) provide a specialised environment for patients who require an "intermediate" level of care between the ICU and the ward, where non-invasive monitoring and assisted ventilation techniques are preferentially applied. Since they are dedicated to the management of "mono-organ" decompensations, treatment of ARF patients in RHDCU avoids the dangerous "under-assistance" in the ward and unnecessary "over-assistance" in ICU. RHDCUs provide a specialised quality of care for ARF with health resources optimisation and their spread throughout health systems has been driven by their high-level of expertise in non-invasive ventilation (NIV), weaning from invasive ventilation, tracheostomy care, and discharging planning for ventilator-dependent patients. Copyright © 2011 European Federation of Internal Medicine. Published by Elsevier B.V. All rights reserved.

  4. Verification and compensation of respiratory motion using an ultrasound imaging system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chuang, Ho-Chiao, E-mail: hchuang@mail.ntut.edu.tw; Hsu, Hsiao-Yu; Chiu, Wei-Hung

    Purpose: The purpose of this study was to determine if it is feasible to use ultrasound imaging as an aid for moving the treatment couch during diagnosis and treatment procedures associated with radiation therapy, in order to offset organ displacement caused by respiratory motion. A noninvasive ultrasound system was used to replace the C-arm device during diagnosis and treatment with the aims of reducing the x-ray radiation dose on the human body while simultaneously being able to monitor organ displacements. Methods: This study used a proposed respiratory compensating system combined with an ultrasound imaging system to monitor the compensation effectmore » of respiratory motion. The accuracy of the compensation effect was verified by fluoroscopy, which means that fluoroscopy could be replaced so as to reduce unnecessary radiation dose on patients. A respiratory simulation system was used to simulate the respiratory motion of the human abdomen and a strain gauge (respiratory signal acquisition device) was used to capture the simulated respiratory signals. The target displacements could be detected by an ultrasound probe and used as a reference for adjusting the gain value of the respiratory signal used by the respiratory compensating system. This ensured that the amplitude of the respiratory compensation signal was a faithful representation of the target displacement. Results: The results show that performing respiratory compensation with the assistance of the ultrasound images reduced the compensation error of the respiratory compensating system to 0.81–2.92 mm, both for sine-wave input signals with amplitudes of 5, 10, and 15 mm, and human respiratory signals; this represented compensation of the respiratory motion by up to 92.48%. In addition, the respiratory signals of 10 patients were captured in clinical trials, while their diaphragm displacements were observed simultaneously using ultrasound. Using the respiratory compensating system to offset, the diaphragm displacement resulted in compensation rates of 60%–84.4%. Conclusions: This study has shown that a respiratory compensating system combined with noninvasive ultrasound can provide real-time compensation of the respiratory motion of patients.« less

  5. The US Army Burn Center: Professional Service During 10 Years of War

    DTIC Science & Technology

    2012-01-01

    therapist Registered respiratory therapist Clinical nutrition Registered dietician Dietary technician Social work and case management Licensed clinical...resuscitation fluid volume cal- culation termed the Rule of Ten.12 Education regarding the intended use of the CPG and the BRF was provided through...Intraoperative hemodynamic monitoring includes the use of transesophageal echocardiography and noninvasive continuous hemoglobin monitoring combined with

  6. Effectiveness and predictors of failure of noninvasive mechanical ventilation in acute respiratory failure.

    PubMed

    Martín-González, F; González-Robledo, J; Sánchez-Hernández, F; Moreno-García, M N; Barreda-Mellado, I

    2016-01-01

    To assess the effectiveness and identify predictors of failure of noninvasive ventilation. A retrospective, longitudinal descriptive study was made. Adult patients with acute respiratory failure. A total of 410 consecutive patients with noninvasive ventilation treated in an Intensive Care Unit of a tertiary university hospital from 2006 to 2011. Noninvasive ventilation. Demographic variables and clinical and laboratory test parameters at the start and two hours after the start of noninvasive ventilation. Evolution during admission to the Unit and until hospital discharge. The failure rate was 50%, with an overall mortality rate of 33%. A total of 156 patients had hypoxemic respiratory failure, 87 postextubation respiratory failure, 78 exacerbation of chronic obstructive pulmonary disease, 61 hypercapnic respiratory failure without chronic obstructive pulmonary disease, and 28 had acute pulmonary edema. The failure rates were 74%, 54%, 27%, 31% and 21%, respectively. The etiology of respiratory failure, serum bilirubin at the start, APACHEII score, radiological findings, the need for sedation to tolerate noninvasive ventilation, changes in level of consciousness, PaO2/FIO2 ratio, respiratory rate and heart rate from the start and two hours after the start of noninvasive ventilation were independently associated to failure. The effectiveness of noninvasive ventilation varies according to the etiology of respiratory failure. Its use in hypoxemic respiratory failure and postextubation respiratory failure should be assessed individually. Predictors of failure could be useful to prevent delayed intubation. Copyright © 2015 Elsevier España, S.L.U. and SEMICYUC. All rights reserved.

  7. Field Programmable Gate Array (FPGA) Respiratory Monitoring System Using a Flow Microsensor and an Accelerometer

    NASA Astrophysics Data System (ADS)

    Mellal, Idir; Laghrouche, Mourad; Bui, Hung Tien

    2017-04-01

    This paper describes a non-invasive system for respiratory monitoring using a Micro Electro Mechanical Systems (MEMS) flow sensor and an IMU (Inertial Measurement Unit) accelerometer. The designed system is intended to be wearable and used in a hospital or at home to assist people with respiratory disorders. To ensure the accuracy of our system, we proposed a calibration method based on ANN (Artificial Neural Network) to compensate the temperature drift of the silicon flow sensor. The sigmoid activation functions used in the ANN model were computed with the CORDIC (COordinate Rotation DIgital Computer) algorithm. This algorithm was also used to estimate the tilt angle in body position. The design was implemented on reconfigurable platform FPGA.

  8. In-airway molecular flow sensing: A new technology for continuous, noninvasive monitoring of oxygen consumption in critical care.

    PubMed

    Ciaffoni, Luca; O'Neill, David P; Couper, John H; Ritchie, Grant A D; Hancock, Gus; Robbins, Peter A

    2016-08-01

    There are no satisfactory methods for monitoring oxygen consumption in critical care. To address this, we adapted laser absorption spectroscopy to provide measurements of O2, CO2, and water vapor within the airway every 10 ms. The analyzer is integrated within a novel respiratory flow meter that is an order of magnitude more precise than other flow meters. Such precision, coupled with the accurate alignment of gas concentrations with respiratory flow, makes possible the determination of O2 consumption by direct integration over time of the product of O2 concentration and flow. The precision is illustrated by integrating the balance gas (N2 plus Ar) flow and showing that this exchange was near zero. Measured O2 consumption changed by <5% between air and O2 breathing. Clinical capability was illustrated by recording O2 consumption during an aortic aneurysm repair. This device now makes easy, accurate, and noninvasive measurement of O2 consumption for intubated patients in critical care possible.

  9. In-airway molecular flow sensing: A new technology for continuous, noninvasive monitoring of oxygen consumption in critical care

    PubMed Central

    Ciaffoni, Luca; O’Neill, David P.; Couper, John H.; Ritchie, Grant A. D.; Hancock, Gus; Robbins, Peter A.

    2016-01-01

    There are no satisfactory methods for monitoring oxygen consumption in critical care. To address this, we adapted laser absorption spectroscopy to provide measurements of O2, CO2, and water vapor within the airway every 10 ms. The analyzer is integrated within a novel respiratory flow meter that is an order of magnitude more precise than other flow meters. Such precision, coupled with the accurate alignment of gas concentrations with respiratory flow, makes possible the determination of O2 consumption by direct integration over time of the product of O2 concentration and flow. The precision is illustrated by integrating the balance gas (N2 plus Ar) flow and showing that this exchange was near zero. Measured O2 consumption changed by <5% between air and O2 breathing. Clinical capability was illustrated by recording O2 consumption during an aortic aneurysm repair. This device now makes easy, accurate, and noninvasive measurement of O2 consumption for intubated patients in critical care possible. PMID:27532048

  10. [Concepts and monitoring of pulmonary mechanic in patients under ventilatory support in intensive care unit].

    PubMed

    Faustino, Eduardo Antonio

    2007-06-01

    In mechanical ventilation, invasive and noninvasive, the knowledge of respiratory mechanic physiology is indispensable to take decisions and into the efficient management of modern ventilators. Monitoring of pulmonary mechanic parameters is been recommended from all the review works and clinical research. The objective of this study was review concepts of pulmonary mechanic and the methods used to obtain measures in the bed side, preparing a rational sequence to obtain this data. It was obtained bibliographic review through data bank LILACS, MedLine and PubMed, from the last ten years. This review approaches parameters of resistance, pulmonary compliance and intrinsic PEEP as primordial into comprehension of acute respiratory failure and mechanic ventilatory support, mainly in acute respiratory distress syndrome (ARDS) and in chronic obstructive pulmonary disease (COPD). Monitoring pulmonary mechanics in patients under mechanical ventilation in intensive care units gives relevant informations and should be implemented in a rational and systematic way.

  11. Respiratory Care Received by Individuals With Duchenne Muscular Dystrophy From 2000 to 2011.

    PubMed

    Andrews, Jennifer G; Soim, Aida; Pandya, Shree; Westfield, Christina P; Ciafaloni, Emma; Fox, Deborah J; Birnkrant, David J; Cunniff, Christopher M; Sheehan, Daniel W

    2016-10-01

    Duchenne muscular dystrophy (DMD) causes progressive respiratory muscle weakness and decline in function, which can go undetected without monitoring. DMD respiratory care guidelines recommend scheduled respiratory assessments and use of respiratory assist devices. To determine the extent of adherence to these guidelines, we evaluated respiratory assessments and interventions among males with DMD in the Muscular Dystrophy Surveillance, Tracking, and Research Network (MD STARnet) from 2000 to 2011. MD STARnet is a population-based surveillance system that identifies all individuals born during or after 1982 residing in Arizona, Colorado, Georgia, Hawaii, Iowa, and western New York with Duchenne or Becker muscular dystrophy. We analyzed MD STARnet respiratory care data for non-ambulatory adolescent males (12-17 y old) and men (≥18 y old) with DMD, assessing whether: (1) pulmonary function was measured twice yearly; (2) awake and asleep hypoventilation testing was performed at least yearly; (3) home mechanical insufflation-exsufflation, noninvasive ventilation, and tracheostomy/ventilators were prescribed; and (4) pulmonologists provided evaluations. During 2000-2010, no more than 50% of both adolescents and men had their pulmonary function monitored twice yearly in any of the years; 67% or fewer were assessed for awake and sleep hypoventilation yearly. Although the use of mechanical insufflation-exsufflation and noninvasive ventilation is probably increasing, prior use of these devices did not prevent all tracheostomies, and at least 18 of 29 tracheostomies were performed due to acute respiratory illnesses. Fewer than 32% of adolescents and men had pulmonologist evaluations in 2010-2011. Since the 2004 publication of American Thoracic Society guidelines, there have been few changes in pulmonary clinical practice. Frequencies of respiratory assessments and assist device use among males with DMD were lower than recommended in clinical guidelines. Collaboration of respiratory therapists and pulmonologists with clinicians caring for individuals with DMD should be encouraged to ensure access to the full spectrum of in-patient and out-patient pulmonary interventions. Copyright © 2016 by Daedalus Enterprises.

  12. The analysis of volatile organic compounds in exhaled breath and biomarkers in exhaled breath condensate in children - clinical tools or scientific toys?

    PubMed

    van Mastrigt, E; de Jongste, J C; Pijnenburg, M W

    2015-07-01

    Current monitoring strategies for respiratory diseases are mainly based on clinical features, lung function and imaging. As airway inflammation is the hallmark of many respiratory diseases in childhood, noninvasive methods to assess the presence and severity of airway inflammation might be helpful in both diagnosing and monitoring paediatric respiratory diseases. At present, the measurement of fractional exhaled nitric oxide is the only noninvasive method available to assess eosinophilic airway inflammation in clinical practice. We aimed to evaluate whether the analysis of volatile organic compounds (VOCs) in exhaled breath (EB) and biomarkers in exhaled breath condensate (EBC) is helpful in diagnosing and monitoring respiratory diseases in children. An extensive literature search was conducted in Medline, Embase and PubMed on the analysis and applications of VOCs in EB and EBC in children. We retrieved 1165 papers, of which nine contained original data on VOCs in EB and 84 on biomarkers in EBC. These were included in this review. We give an overview of the clinical applications in childhood and summarize the methodological issues. Several VOCs in EB and biomarkers in EBC have the potential to distinguish patients from healthy controls and to monitor treatment responses. Lack of standardization of collection methods and analysis techniques hampers the introduction in clinical practice. The measurement of metabolomic profiles may have important advantages over detecting single markers. There is a lack of longitudinal studies and external validation to reveal whether EB and EBC analysis have added value in the diagnostic process and follow-up of children with respiratory diseases. In conclusion, the use of VOCs in EB and biomarkers in EBC as markers of inflammatory airway diseases in children is still a research tool and not validated for clinical use. © 2014 John Wiley & Sons Ltd.

  13. Professional figures in intermediate intensive units.

    PubMed

    Quadri, A; Simoni, P; Clini, E; Errera, D; Foglio, K; Vitacca, M; Schena, M

    1994-12-01

    In Italy, respiratory intermediate intensive care units (IICUs) are not yet considered as autonomous hospital departments. The IICU of the Rehabilitation Department of the Medical Centre of Gussago (12 monitored beds) provides care for respiratory and cardiac patients. Ventilatory assistance and noninvasive modalities both in treatment and monitoring suggest a multidisciplinary approach to the patient. Highly professional figures should, therefore, be singled out to provide care in a respiratory IICU. The medical staff is composed of one anaesthesiologist, one cardiologist and one pulmonologist, who can integrate care when respiratory complications occur in a cardiological patient, or when cardiac events affect a respiratory patient. Nurses are capable of specific activities, especially when ventilatory assistance is required. The presence of a physiotherapist reduces the nursing workload, especially for ventilated individuals. The psychological aspect is undertaken by a specialist. Finally, an expert in nutrition provides an individualized dietary regimen. Our 4 year experience encourages such a multidisciplinary approach. An ideal integration of the professional activities should provide adequate and individual care for patients admitted to an IICU.

  14. Pulse oximetry-derived respiratory rate in general care floor patients.

    PubMed

    Addison, Paul S; Watson, James N; Mestek, Michael L; Ochs, James P; Uribe, Alberto A; Bergese, Sergio D

    2015-02-01

    Respiratory rate is recognized as a clinically important parameter for monitoring respiratory status on the general care floor (GCF). Currently, intermittent manual assessment of respiratory rate is the standard of care on the GCF. This technique has several clinically-relevant shortcomings, including the following: (1) it is not a continuous measurement, (2) it is prone to observer error, and (3) it is inefficient for the clinical staff. We report here on an algorithm designed to meet clinical needs by providing respiratory rate through a standard pulse oximeter. Finger photoplethysmograms were collected from a cohort of 63 GCF patients monitored during free breathing over a 25-min period. These were processed using a novel in-house algorithm based on continuous wavelet-transform technology within an infrastructure incorporating confidence-based averaging and logical decision-making processes. The computed oximeter respiratory rates (RRoxi) were compared to an end-tidal CO2 reference rate (RRETCO2). RRETCO2 ranged from a lowest recorded value of 4.7 breaths per minute (brpm) to a highest value of 32.0 brpm. The mean respiratory rate was 16.3 brpm with standard deviation of 4.7 brpm. Excellent agreement was found between RRoxi and RRETCO2, with a mean difference of -0.48 brpm and standard deviation of 1.77 brpm. These data demonstrate that our novel respiratory rate algorithm is a potentially viable method of monitoring respiratory rate in GCF patients. This technology provides the means to facilitate continuous monitoring of respiratory rate, coupled with arterial oxygen saturation and pulse rate, using a single non-invasive sensor in low acuity settings.

  15. Integrated circuits and electrode interfaces for noninvasive physiological monitoring.

    PubMed

    Ha, Sohmyung; Kim, Chul; Chi, Yu M; Akinin, Abraham; Maier, Christoph; Ueno, Akinori; Cauwenberghs, Gert

    2014-05-01

    This paper presents an overview of the fundamentals and state of the-art in noninvasive physiological monitoring instrumentation with a focus on electrode and optrode interfaces to the body, and micropower-integrated circuit design for unobtrusive wearable applications. Since the electrode/optrode-body interface is a performance limiting factor in noninvasive monitoring systems, practical interface configurations are offered for biopotential acquisition, electrode-tissue impedance measurement, and optical biosignal sensing. A systematic approach to instrumentation amplifier (IA) design using CMOS transistors operating in weak inversion is shown to offer high energy and noise efficiency. Practical methodologies to obviate 1/f noise, counteract electrode offset drift, improve common-mode rejection ratio, and obtain subhertz high-pass cutoff are illustrated with a survey of the state-of-the-art IAs. Furthermore, fundamental principles and state-of-the-art technologies for electrode-tissue impedance measurement, photoplethysmography, functional near-infrared spectroscopy, and signal coding and quantization are reviewed, with additional guidelines for overall power management including wireless transmission. Examples are presented of practical dry-contact and noncontact cardiac, respiratory, muscle and brain monitoring systems, and their clinical applications.

  16. Non-Invasive Monitoring of Cardiac Output in Critical Care Medicine.

    PubMed

    Nguyen, Lee S; Squara, Pierre

    2017-01-01

    Critically ill patients require close hemodynamic monitoring to titrate treatment on a regular basis. It allows administering fluid with parsimony and adjusting inotropes and vasoactive drugs when necessary. Although invasive monitoring is considered as the reference method, non-invasive monitoring presents the obvious advantage of being associated with fewer complications, at the expanse of accuracy, precision, and step-response change. A great many methods and devices are now used over the world, and this article focuses on several of them, providing with a brief review of related underlying physical principles and validation articles analysis. Reviewed methods include electrical bioimpedance and bioreactance, respiratory-derived cardiac output (CO) monitoring technique, pulse wave transit time, ultrasound CO monitoring, multimodal algorithmic estimation, and inductance thoracocardiography. Quality criteria with which devices were reviewed included: accuracy (closeness of agreement between a measurement value and a true value of the measured), precision (closeness of agreement between replicate measurements on the same or similar objects under specified conditions), and step response change (delay between physiological change and its indication). Our conclusion is that the offer of non-invasive monitoring has improved in the past few years, even though further developments are needed to provide clinicians with sufficiently accurate devices for routine use, as alternative to invasive monitoring devices.

  17. Development of a diaphragmatic motion-based elastography framework for assessment of liver stiffness

    NASA Astrophysics Data System (ADS)

    Weis, Jared A.; Johnsen, Allison M.; Wile, Geoffrey E.; Yankeelov, Thomas E.; Abramson, Richard G.; Miga, Michael I.

    2015-03-01

    Evaluation of mechanical stiffness imaging biomarkers, through magnetic resonance elastography (MRE), has shown considerable promise for non-invasive assessment of liver stiffness to monitor hepatic fibrosis. MRE typically requires specialized externally-applied vibratory excitation and scanner-specific motion-sensitive pulse sequences. In this work, we have developed an elasticity imaging approach that utilizes natural diaphragmatic respiratory motion to induce deformation and eliminates the need for external deformation excitation hardware and specialized pulse sequences. Our approach uses clinically-available standard of care volumetric imaging acquisitions, combined with offline model-based post-processing to generate volumetric estimates of stiffness within the liver and surrounding tissue structures. We have previously developed a novel methodology for non-invasive elasticity imaging which utilizes a model-based elasticity reconstruction algorithm and MR image volumes acquired under different states of deformation. In prior work, deformation was external applied through inflation of an air bladder placed within the MR radiofrequency coil. In this work, we extend the methodology with the goal of determining the feasibility of assessing liver mechanical stiffness using diaphragmatic respiratory motion between end-inspiration and end-expiration breath-holds as a source of deformation. We present initial investigations towards applying this methodology to assess liver stiffness in healthy volunteers and cirrhotic patients. Our preliminary results suggest that this method is capable of non-invasive image-based assessment of liver stiffness using natural diaphragmatic respiratory motion and provides considerable enthusiasm for extension of our approach towards monitoring liver stiffness in cirrhotic patients with limited impact to standard-of-care clinical imaging acquisition workflow.

  18. Epidemiology of Noninvasive Ventilation in Pediatric Cardiac ICUs.

    PubMed

    Romans, Ryan A; Schwartz, Steven M; Costello, John M; Chanani, Nikhil K; Prodhan, Parthak; Gazit, Avihu Z; Smith, Andrew H; Cooper, David S; Alten, Jeffrey; Mistry, Kshitij P; Zhang, Wenying; Donohue, Janet E; Gaies, Michael

    2017-10-01

    To describe the epidemiology of noninvasive ventilation therapy for patients admitted to pediatric cardiac ICUs and to assess practice variation across hospitals. Retrospective cohort study using prospectively collected clinical registry data. Pediatric Cardiac Critical Care Consortium clinical registry. Patients admitted to cardiac ICUs at PC4 hospitals. None. We analyzed all cardiac ICU encounters that included any respiratory support from October 2013 to December 2015. Noninvasive ventilation therapy included high flow nasal cannula and positive airway pressure support. We compared patient and, when relevant, perioperative characteristics of those receiving noninvasive ventilation to all others. Subgroup analysis was performed on neonates and infants undergoing major cardiovascular surgery. To examine duration of respiratory support, we created a casemix-adjustment model and calculated adjusted mean durations of total respiratory support (mechanical ventilation + noninvasive ventilation), mechanical ventilation, and noninvasive ventilation. We compared adjusted duration of support across hospitals. The cohort included 8,940 encounters from 15 hospitals: 3,950 (44%) received noninvasive ventilation and 72% were neonates and infants. Medical encounters were more likely to include noninvasive ventilation than surgical. In surgical neonates and infants, 2,032 (55%) received postoperative noninvasive ventilation. Neonates, extracardiac anomalies, single ventricle, procedure complexity, preoperative respiratory support, mechanical ventilation duration, and postoperative disease severity were associated with noninvasive ventilation therapy (p < 0.001 for all). Across hospitals, noninvasive ventilation use ranged from 32% to 65%, and adjusted mean noninvasive ventilation duration ranged from 1 to 4 days (3-d observed mean). Duration of total adjusted respiratory support was more strongly correlated with duration of mechanical ventilation compared with noninvasive ventilation (Pearson r = 0.93 vs 0.71, respectively). Noninvasive ventilation use is common in cardiac ICUs, especially in patients admitted for medical conditions, infants, and those undergoing high complexity surgery. We observed wide variation in noninvasive ventilation use across hospitals, though the primary driver of total respiratory support time seems to be duration of mechanical ventilation.

  19. Autonomic dysfunction with early respiratory syncytial virus-related infection.

    PubMed

    Stock, Claire; Teyssier, Georges; Pichot, Vincent; Goffaux, Philippe; Barthelemy, Jean-Claude; Patural, Hugues

    2010-08-25

    Apparent life-threatening events (ALTE) and/or prolonged apnoea have been well-documented during respiratory syncytial virus (RSV) infection in infants less than 2 months of age but fundamental mechanisms remain unclear. The possibility of a central origin for the development of severe cardiac and respiratory events encouraged us, to explore the autonomic nervous system (ANS) profile of infected infants, since ANS activity may contribute to the constellation of symptoms observed during severe forms of RSV bronchiolitis. Eight infants (2 preterm and 6 full-term) less than 2 months of age and presenting with severe and apnoeic forms of RSV infection were evaluated using non-invasive electrophysiological monitoring obtained simultaneously for approximately 2 consecutive hours, including a quiet sleep period. Eight control subjects, paired for gestational and postnatal age, were also evaluated. ANS status was monitored using electrocardiogram recordings and quantified through a frequency-domain analysis of heart rate variability (HRV). This included sympathetic (VLF and LF) and parasympathetic (HF) indices as well as a measure of baroreflex sensitivity (BRS) obtained using non-invasive continuous arterial pressure. Regardless of gestational and postnatal age, heart rate variability components (Ptot, VLF, LF, and HF) and baroreflex components (alpha LF, alpha HF and sBR) were found to be significantly lower in the RSV-infected group than in the control group (p<0.05). RSV infection in neonates is associated with profound central autonomic dysfunction. The potentially fatal consequence stresses the importance of maintaining prolonged cardiopulmonary monitoring. Copyright 2010 Elsevier B.V. All rights reserved.

  20. A Comparison of Measurements of Change in Respiratory Status in Spontaneously Breathing Volunteers by the ExSpiron Noninvasive Respiratory Volume Monitor Versus the Capnostream Capnometer.

    PubMed

    Williams, George W; George, Christy A; Harvey, Brian C; Freeman, Jenny E

    2017-01-01

    Current respiratory monitoring technologies such as pulse oximetry and capnography have been insufficient to identify early signs of respiratory compromise in nonintubated patients. Pulse oximetry, when used appropriately, will alert the caregiver to an episode of dangerous hypoxemia. However, desaturation lags significantly behind hypoventilation and alarm fatigue due to false alarms poses an additional problem. Capnography, which measures end-tidal CO2 (EtCO2) and respiratory rate (RR), has not been universally used for nonintubated patients for multiple reasons, including the inability to reliably relate EtCO2 to the level of impending respiratory compromise and lack of patient compliance. Serious complications related to respiratory compromise continue to occur as evidenced by the Anesthesiology 2015 Closed Claims Report. The Anesthesia Patient Safety Foundation has stressed the need to improve monitoring modalities so that "no patient will be harmed by opioid-induced respiratory depression." A recently available, Food and Drug Administration-approved noninvasive respiratory volume monitor (RVM) can continuously and accurately monitor actual ventilation metrics: tidal volume, RR, and minute ventilation (MV). We designed this study to compare the capabilities of capnography versus the RVM to detect changes in respiratory metrics. Forty-eight volunteer subjects completed the study. RVM measurements (MV and RR) were collected simultaneously with capnography (EtCO2 and RR) using 2 sampling methods (nasal scoop cannula and snorkel mouthpiece with in-line EtCO2 sensor). For each sampling method, each subject performed 6 breathing trials at 3 different prescribed RRs (slow [5 min], normal [12.6 ± 0.6 min], and fast [25 min]). All data are presented as mean ± SEM unless otherwise indicated. Following transitions in prescribed RRs, the RVM reached a new steady state value of MV in 37.7 ± 1.4 seconds while EtCO2 changes were notably slower, often failing to reach a new asymptote before a 2.5-minute threshold. RRs as measured by RVM and capnography during steady breathing were strongly correlated (R = 0.98 ± 0.01, bias = Capnograph-based RR - RVM-based RR = 0.21 ± 1.24 [SD] min). As expected, changes in MV were negatively correlated with changes in EtCO2. However, large changes in MV following transitions in prescribed RR resulted in relatively small changes in EtCO2 (instrument sensitivity = ΔEtCO2/ΔMV = -0.71 ± 0.11 and -0.55 ± 0.11 mm Hg per 1 L/min for nasal and in-line sampling, respectively). Nasal cannula EtCO2 measurements were on average 4 mm Hg lower than in-line measurements. RVM measurements of MV change more rapidly and by a greater degree than capnography in response to respiratory changes in nonintubated patients. Earlier detection could enable earlier intervention that could potentially reduce frequency and severity of complications due to respiratory depression.

  1. [Hospital management of acute respiratory failure: the role of the pulmonologist and of the respiratory intensive care unit].

    PubMed

    Scala, Raffaele

    2009-04-01

    Acute respiratory failure (ARF) is one of the most common and severe urgencies of the modern medicine which may require the application of mechanical ventilation and a careful monitoring of the patient's conditions. With the popularity of non-invasive ventilation and the interest of the pulmonologist for the care of the respiratory critical patient, in Italy there has been the spreading of Respiratory Intensive Care Units (RICU), which are as intermediate specialist structures in terms of intensity of care between the General Intensive Care Unit and the ordinary ward. In this article, the author analysed the cultural, scientific and organizational aspects of the central role played by the pulmonologist who's working in the RICU in the complex intra-hospital multi-disciplinary management of ARF.

  2. Real Time Apnoea Monitoring of Children Using the Microsoft Kinect Sensor: A Pilot Study.

    PubMed

    Al-Naji, Ali; Gibson, Kim; Lee, Sang-Heon; Chahl, Javaan

    2017-02-03

    The objective of this study was to design a non-invasive system for the observation of respiratory rates and detection of apnoea using analysis of real time image sequences captured in any given sleep position and under any light conditions (even in dark environments). A Microsoft Kinect sensor was used to visualize the variations in the thorax and abdomen from the respiratory rhythm. These variations were magnified, analyzed and detected at a distance of 2.5 m from the subject. A modified motion magnification system and frame subtraction technique were used to identify breathing movements by detecting rapid motion areas in the magnified frame sequences. The experimental results on a set of video data from five subjects (3 h for each subject) showed that our monitoring system can accurately measure respiratory rate and therefore detect apnoea in infants and young children. The proposed system is feasible, accurate, safe and low computational complexity, making it an efficient alternative for non-contact home sleep monitoring systems and advancing health care applications.

  3. The Evaluation of a Noninvasive Respiratory Volume Monitor in Pediatric Patients Undergoing General Anesthesia.

    PubMed

    Gomez-Morad, Andrea D; Cravero, Joseph P; Harvey, Brian C; Bernier, Rachel; Halpin, Erin; Walsh, Brian; Nasr, Viviane G

    2017-12-01

    Pediatric patients following surgery are at risk for respiratory compromise such as hypoventilation and hypoxemia depending on their age, comorbidities, and type of surgery. Quantitative measurement of ventilation in nonintubated infants/children is a difficult and inexact undertaking. Current respiratory assessment in nonintubated patients relies on oximetry data, respiratory rate (RR) monitors, and subjective clinical assessment, but there is no objective measure of respiratory parameters that could be utilized to predict early respiratory compromise. New advances in technology and digital signal processing have led to the development of an impedance-based respiratory volume monitor (RVM, ExSpiron, Respiratory Motion, Inc, Waltham, MA). The RVM has been shown to provide accurate real-time, continuous, noninvasive measurements of tidal volume (TV), minute ventilation (MV), and RR in adult patients.In this prospective observational study, our primary aim was to determine whether the RVM accurately measures TV, RR, and MV in pediatric patients. A total of 72 pediatric patients (27 females, 45 males), ASA I to III, undergoing general anesthesia with endotracheal intubation were enrolled. After endotracheal intubation, continuous data of MV, TV, and RR were recorded from the RVM and an in-line monitoring spirometer (NM3 monitor, Phillips Healthcare). RVM and NM3 measurements of MV, TV, and RR were compared during a 10-minute period prior to the incision ("Presurgery") and a 10-minute period after the end of surgery ("Postsurgery"). Relative errors were calculated over 1-minute segment within each 10-minute period. Bias, precision, and accuracy were calculated using Bland-Altman analyses and paired-difference equivalence tests were performed. Combined across the Presurgery and Postsurgery periods, the RVM's mean measurement bias (RVM - NM3 measurement) for MV was -3.8% (95% limits of agreement) (±1.96 SD): (-19.9% to 12.2%), for TV it was -4.9 (-21.0% to 11.3%), and for RR it was 1.1% (-4.1% to 6.2%). The mean measurement accuracies for MV, TV, and RR were 11.9%, 12.0%, and 4.2% (0.6 breaths/min), respectively. Note that lower accuracy numbers correspond to more accurate RVM measurements. The equivalence tests rejected the null hypothesis that the RVM and NM3 have different mean values and conclude with 90% power that the measurements of MV, TV, and RR from the RVM and NM3 are equivalent within ±10%. Our data indicate acceptable agreement between RVM and NM3 measurements in pediatric mechanically-ventilated patients. Future studies assessing the capability of the RVM to detect respiratory compromise in other clinical settings are needed.

  4. Design and preliminary assessment of a smart textile for respiratory monitoring based on an array of Fiber Bragg Gratings.

    PubMed

    Massaroni, C; Ciocchetti, M; Di Tomaso, G; Saccomandi, P; Caponero, M A; Polimadei, A; Formica, D; Schena, E

    2016-08-01

    Comfortable and easy to wear smart textiles have gained popularity for continuous respiratory monitoring. Among different emerging technologies, smart textiles based on fiber optic sensors (FOSs) have several advantages, like Magnetic Resonance (MR)-compatibility and good metrological properties. In this paper we report on the development and assessment of an MR-compatible smart textiles based on FOSs for respiratory monitoring. The system consists of six fiber Bragg grating (FBG) sensors glued on the textile to monitor six compartments of the chest wall (i.e., right and left upper thorax, right and left abdominal rib cage, and right and left abdomen). This solution allows monitoring both global respiratory parameters and each compartment volume change. The system converts thoracic movements into strain measured by the FBGs. The positioning of the FBGs was optimized by experiments performed using an optoelectronic system. The feasibility of the smart textile was assessed on 6 healthy volunteers. Experimental data were compared to the ones estimated by an optoelectronic plethysmography used as reference. Promising results were obtained on both breathing period (maximum percentage error is 1.14%), inspiratory and expiratory period, as well as on total volume change (mean percentage difference between the two systems was ~14%). The Bland-Altman analysis shows a satisfactory accuracy for the parameters under investigation. The proposed system is safe and non-invasive, MR-compatible, and allows monitoring compartmental volumes.

  5. A rate-based transcutaneous CO2 sensor for noninvasive respiration monitoring.

    PubMed

    Chatterjee, M; Ge, X; Kostov, Y; Luu, P; Tolosa, L; Woo, H; Viscardi, R; Falk, S; Potts, R; Rao, G

    2015-05-01

    The pain and risk of infection associated with invasive blood sampling for blood gas measurements necessitate the search for reliable noninvasive techniques. In this work we developed a novel rate-based noninvasive method for a safe and fast assessment of respiratory status. A small sampler was built to collect the gases diffusing out of the skin. It was connected to a CO2 sensor through gas-impermeable tubing. During a measurement, the CO2 initially present in the sampler was first removed by purging it with nitrogen. The gases in the system were then recirculated between the sampler and the CO2 sensor, and the CO2 diffusion rate into the sampler was measured. Because the measurement is based on the initial transcutaneous diffusion rate, reaching mass transfer equilibrium and heating the skin is no longer required, thus, making it much faster and safer than traditional method. A series of designed experiments were performed to analyze the effect of the measurement parameters such as sampler size, measurement location, subject positions, and movement. After the factor analysis tests, the prototype was sent to a level IV NICU for clinical trial. The results show that the measured initial rate of increase in CO2 partial pressure is linearly correlated with the corresponding arterial blood gas measurements. The new approach can be used as a trending tool, making frequent blood sampling unnecessary for respiratory status monitoring.

  6. Absolute electrical impedance tomography (aEIT) guided ventilation therapy in critical care patients: simulations and future trends.

    PubMed

    Denaï, Mouloud A; Mahfouf, Mahdi; Mohamad-Samuri, Suzani; Panoutsos, George; Brown, Brian H; Mills, Gary H

    2010-05-01

    Thoracic electrical impedance tomography (EIT) is a noninvasive, radiation-free monitoring technique whose aim is to reconstruct a cross-sectional image of the internal spatial distribution of conductivity from electrical measurements made by injecting small alternating currents via an electrode array placed on the surface of the thorax. The purpose of this paper is to discuss the fundamentals of EIT and demonstrate the principles of mechanical ventilation, lung recruitment, and EIT imaging on a comprehensive physiological model, which combines a model of respiratory mechanics, a model of the human lung absolute resistivity as a function of air content, and a 2-D finite-element mesh of the thorax to simulate EIT image reconstruction during mechanical ventilation. The overall model gives a good understanding of respiratory physiology and EIT monitoring techniques in mechanically ventilated patients. The model proposed here was able to reproduce consistent images of ventilation distribution in simulated acutely injured and collapsed lung conditions. A new advisory system architecture integrating a previously developed data-driven physiological model for continuous and noninvasive predictions of blood gas parameters with the regional lung function data/information generated from absolute EIT (aEIT) is proposed for monitoring and ventilator therapy management of critical care patients.

  7. [Long-term non-invasive ventilation in chronic obstructive pulmonary disease patients].

    PubMed

    Schopfer, Léonore; Groenendijk, Lena; Janssens, Jean-Paul; Younossian, Alain Bigin; Vignaux, Laurence

    2018-01-31

    Non-invasive ventilation (NIV) is recognized as first line therapy in acute hypercapnic respiratory failure and chronic alveolar hypoventilation caused by several diseases (restrictive thoracic disorders, neuromuscular disease and obesity-hypoventilation syndrome). In Switzerland and other European countries, long-term NIV has also been applied in hypercapnic patients with chronic obstructive pulmonary disease (COPD). However, only recently has conclusive evidence showing benefits of long-term NIV become available. Long-term NIV in COPD has now shown its efficacy in many studies. However, despite these findings, indications, ventilatory settings and monitoring remain poorly known and topic of debate.

  8. Hypoxic events and concomitant factors in preterm infants on non-invasive ventilation.

    PubMed

    Fathabadi, Omid Sadeghi; Gale, Timothy; Wheeler, Kevin; Plottier, Gemma; Owen, Louise S; Olivier, J C; Dargaville, Peter A

    2017-04-01

    Automated control of inspired oxygen for newborn infants is an emerging technology, currently limited by reliance on a single input signal (oxygen saturation, SpO 2 ). This is while other signals that may herald the onset of hypoxic events or identify spurious hypoxia are not usually utilised. We wished to assess the frequency of apnoea, loss of circuit pressure and/or motion artefact in proximity to hypoxic events in preterm infants on non-invasive ventilation. Hypoxic events (SpO 2  < 80 %) were identified using a previously acquired dataset obtained from preterm infants receiving non-invasive ventilation. Events with concomitant apnoea, loss of circuit pressure or oximetry motion artefact were annotated, and the frequency of each of these factors was determined. The effect of duration and timing of apnoea on the characteristics of the associated hypoxic events was studied. Among 1224 hypoxic events, 555 (45 %) were accompanied by apnoea, 31 (2.5 %) by loss of circuit pressure and 696 (57 %) by motion artefact, while for 224 (18 %) there were no concomitant factors identified. Respiratory pauses of longer duration (>15 s) preceding hypoxic events, were associated with a relatively slow decline in SpO 2 and more prolonged hypoxia compared to shorter pauses. Hypoxic events are frequently accompanied by respiratory pauses and/or motion artefact. Real-time monitoring and input of respiratory waveform may thus improve the function of automated oxygen controllers, allowing pre-emptive responses to respiratory pauses. Furthermore, use of motion-resistant oximeters and plethysmographic waveform assessment procedures will help to optimise feedback control of inspired oxygen delivery.

  9. Obstructive sleep apnea in Down syndrome: Benefits of surgery and noninvasive respiratory support.

    PubMed

    Dudoignon, Benjamin; Amaddeo, Alessandro; Frapin, Annick; Thierry, Briac; de Sanctis, Livio; Arroyo, Jorge Olmo; Khirani, Sonia; Fauroux, Brigitte

    2017-08-01

    Children with Down syndrome are at increased risk of obstructive sleep apnea (OSA). The aim of the study was to describe the management of OSA in a large cohort of children with Down syndrome. A retrospective analysis of sleep studies and consequent management was performed for all consecutive Down syndrome patients evaluated between September 2013 and April 2016. The data of 57 patients were analyzed: 51/53 had an interpretable overnight polygraphy and 4 the recording of nocturnal gas exchange. Mean age at baseline sleep study was 6.2 ± 5.9 years. Eighteen patients (32%) had prior upper airway surgery. Mean apnea-hypopnea index (AHI) was 14 ± 16 events/hr with 41 of the 51 (80%) patients having OSA with an AHI >1 event/hr and 20 patients (39%) having an AHI ≥10 events/hr. Consequently, eight patients (14%) had upper airway surgery. OSA improved in all patients except two who needed noninvasive respiratory support. Nineteen (33%) patients required noninvasive respiratory support. Mean age at noninvasive respiratory support initiation was 7 ± 7 years. On 11 patients with objective adherence data available, mean compliance at 2 ± 1 years of treatment was excellent with an average use per night of 8 hr46 ± 3 hr59 and 9 patients using the noninvasive respiratory support >4 hr/night. Noninvasive respiratory support was associated with an improvement of nocturnal gas exchange. The prevalence of OSA is high in Down syndrome. Upper airway surgery is not always able to correct OSA. Noninvasive respiratory support represents then an effective treatment for OSA and good compliance may be achieved in a majority of patients. © 2017 Wiley Periodicals, Inc.

  10. Real Time Apnoea Monitoring of Children Using the Microsoft Kinect Sensor: A Pilot Study

    PubMed Central

    Al-Naji, Ali; Gibson, Kim; Lee, Sang-Heon; Chahl, Javaan

    2017-01-01

    The objective of this study was to design a non-invasive system for the observation of respiratory rates and detection of apnoea using analysis of real time image sequences captured in any given sleep position and under any light conditions (even in dark environments). A Microsoft Kinect sensor was used to visualize the variations in the thorax and abdomen from the respiratory rhythm. These variations were magnified, analyzed and detected at a distance of 2.5 m from the subject. A modified motion magnification system and frame subtraction technique were used to identify breathing movements by detecting rapid motion areas in the magnified frame sequences. The experimental results on a set of video data from five subjects (3 h for each subject) showed that our monitoring system can accurately measure respiratory rate and therefore detect apnoea in infants and young children. The proposed system is feasible, accurate, safe and low computational complexity, making it an efficient alternative for non-contact home sleep monitoring systems and advancing health care applications. PMID:28165382

  11. [Critically ill pediatric hemato-oncology patient: What we do is what we should do?].

    PubMed

    García-Salido, Alberto; Nieto-Moro, Montserrat; Iglesias-Bouzas, María Isabel; González-Vicent, Marta; Serrano-González, Ana; Casado-Flores, Juan

    2016-08-01

    Primary objective, to describe the management and monitorization of critically ill pediatric hemato-oncology patient (CIPHO) in the Spanish pediatric intensive care units (PICU). Secondary objective, through a literature review, to identify possible areas of improvement. Observational transversal descriptive study. An anonymous web-based survey was sent to 324 Spanish pediatric intensivists from April 2011 to May 2011. None of them were pediatric residents. The survey was answered by 105 intensivists, 59/105 always agreed their treatment with the oncologist. In case of hemodynamic instability, non-invasive blood pressure monitoring is always done by 85/105 and almost always optimized by intra-arterial measuring (85/105) and central venous pressure (70/105). If respiratory failure the use of non-invasive ventilation (NIPPV) is always (36/105) or frequently (60/105) established prior to conventional mechanical ventilation. To replace or withdraw non-invasive ventilation only 44/96 of the respondents to this question use a clinical protocol. Before the instauration of conventional mechanical ventilation the oncological prognosis is considered by 72/105. In case of acute oliguric renal failure the renal replacement techniques are widely used (74/105). The withdrawal of sustaining life support is frequently discussed (75/103) and agreed with the oncologist (91/103) and caregivers (81/103). In our study, despite there is not a defined standard-of-care, the respondents showed similar therapeutics and monitorization choices. The use of NIPPV as first respiratory assistance is extended. Prospective, observational and multicenter studies should be developed to establish the results of this management in this population. Copyright © 2015 Asociación Española de Pediatría. Publicado por Elsevier España, S.L.U. All rights reserved.

  12. Rescue therapy by switching to total face mask after failure of face mask-delivered noninvasive ventilation in do-not-intubate patients in acute respiratory failure.

    PubMed

    Lemyze, Malcolm; Mallat, Jihad; Nigeon, Olivier; Barrailler, Stéphanie; Pepy, Florent; Gasan, Gaëlle; Vangrunderbeeck, Nicolas; Grosset, Philippe; Tronchon, Laurent; Thevenin, Didier

    2013-02-01

    To evaluate the impact of switching to total face mask in cases where face mask-delivered noninvasive mechanical ventilation has already failed in do-not-intubate patients in acute respiratory failure. Prospective observational study in an ICU and a respiratory stepdown unit over a 12-month study period. Switching to total face mask, which covers the entire face, when noninvasive mechanical ventilation using facial mask (oronasal mask) failed to reverse acute respiratory failure. Seventy-four patients with a do-not-intubate order and treated by noninvasive mechanical ventilation for acute respiratory failure. Failure of face mask-delivered noninvasive mechanical ventilation was associated with a three-fold increase in in-hospital mortality (36% vs. 10.5%; p = 0.009). Nevertheless, 23 out of 36 patients (64%) in whom face mask-delivered noninvasive mechanical ventilation failed to reverse acute respiratory failure and, therefore, switched to total face mask survived hospital discharge. Reasons for switching from facial mask to total face mask included refractory hypercapnic acute respiratory failure (n = 24, 66.7%), painful skin breakdown or facial mask intolerance (n = 11, 30%), and refractory hypoxemia (n = 1, 2.7%). In the 24 patients switched from facial mask to total face mask because of refractory hypercapnia, encephalopathy score (3 [3-4] vs. 2 [2-3]; p < 0.0001), PaCO2 (87 ± 25 mm Hg vs. 70 ± 17 mm Hg; p < 0.0001), and pH (7.24 ± 0.1 vs. 7.32 ± 0.09; p < 0.0001) significantly improved after 2 hrs of total face mask-delivered noninvasive ventilation. Patients switched early to total face mask (in the first 12 hrs) developed less pressure sores (n = 5, 24% vs. n = 13, 87%; p = 0.0002), despite greater length of noninvasive mechanical ventilation within the first 48 hrs (44 hrs vs. 34 hrs; p = 0.05) and less protective dressings (n = 2, 9.5% vs. n = 8, 53.3%; p = 0.007). The optimal cutoff value for face mask-delivered noninvasive mechanical ventilation duration in predicting facial pressure sores was 11 hrs (area under the receiver operating characteristic curve, 0.86 ± 0.04; 95% confidence interval 0.76-0.93; p < 0.0001; sensitivity, 84%; specificity, 71%). In patients in hypercapnic acute respiratory failure, for whom escalation to intubation is deemed inappropriate, switching to total face mask can be proposed as a last resort therapy when face mask-delivered noninvasive mechanical ventilation has already failed to reverse acute respiratory failure. This strategy is particularly adapted to provide prolonged periods of continuous noninvasive mechanical ventilation while preventing facial pressure sores.

  13. [Effects of noninvasive proportional assist vs pressure support ventilation on respiratory work in chronic obstructive pulmonary disease patients with hypercapnia].

    PubMed

    Zhang, J H; Luo, Q; Zhang, H J; Chen, R C

    2017-06-12

    Objective: To investigate the effect of noninvasive proportional assist ventilation (PAV) on respiratory work in chronic obstructive pulmonary disease(COPD) patients, in comparison to noninvasive pressure support ventilation(PSV). Methods: Ten severe COPD patients with hypercapnia during acute exacerbation were examined. The baseline inspiratory pressure of PSV (PS) and the assistance level of PAV(PA) were titrated by patients' tolerance. In addition to the baseline PS and PA, an additional decrease by 25% (PS-=75% PS, PA-=75% PA) or increase by 25% (PS+ =125% PS, PA+ =125% PA) of the assist level were applied to the patients. After the assessment of unassisted spontaneous breathing (SB), the patient was placed on the 6 levels of noninvasive-PSV and noninvasive-PAV in random sequence. Each level lasted at least 20 minutes. Respiratory rate (RR), tidal volume (Vt), and respiratory work(Wex, Wip and Wv) were measured. Asynchrony index (AI) was calculated. Results: During ventilation, Vt was significantly higher with each assist level than with SB. The Vt was significant increased with PS+ than with PA+ . An increase in expiratory work(Wex) and decrease in inspiratory work(Wip) were observed respectively, with the increasing assist level. The inspiratory muscles assessed by Wip were more unloaded at PS compared with PA [PS: (1.59±1.27) J/min vs PA: (4.99±3.48) J/min P <0.01]. However, the Wex was significantly higher with PS+ than with PA+ [PS+ : (1.17±0.54) J/min vs PA+ : (0.49±0.56)J/min, P <0.01]. The AI was increased with the increasing assist level of PSV [PS-: (0.46±0.57)%, PS: (1.36±1.24)% PS+ : (5.26±4.77)]. No asynchrony events were observed at PA- and PA. "Runaway" (expiratory asynchrony) was observed during PA+ [AI: (2.62±2.72)%]. Conclusions: Noninvasive-PAV can increase the Vt and decrease the Wip of the COPD patients with hypercapnia and avoid the over-assistance. The "Runaway" will occur at assist level higher than that set by tolerance. Physiological data can monitor the patient's responses and the ventilator-patient interaction, which may provide objective criteria for ventilator setting.

  14. Case Report of a Pressure Ulcer Occurring Over the Nasal Bridge Due to a Non-Invasive Ventilation Facial Mask.

    PubMed

    Rathore, Farooq A; Ahmad, Faria; Zahoor, Muhammad Umar U

    2016-10-03

    Non-invasive ventilation (NIV) is used in patients with respiratory failure, sleep apnoea, and dyspnoea related to pulmonary oedema. NIV is provided through a facial mask. Many complications of NIV facial masks have been reported, including the breakdown of facial skin. We report a case of an elderly male admitted with multiple co-morbidities. The facial mask was applied continuously for NIV, without any relief or formal monitoring of the underlying skin. It resulted in a Grade II pressure ulcer. We discuss the possible mechanism and offer advice for prevention of such device-related pressure ulcers.

  15. Three-dimensional ballistocardiography and respiratory motion in sustained microgravity

    NASA Technical Reports Server (NTRS)

    Prisk, G. K.; Verhaeghe, S.; Padeken, D.; Hamacher, H.; Paiva, M.; West, J. B. (Principal Investigator)

    2001-01-01

    BACKGROUND: We measured the three-dimensional ballistocardiogram (BCG) in a free-floating subject in sustained microgravity during spaceflight to test the usefulness of such measurements for future non-invasive monitoring of cardiac function, and to examine the effects of respiratory movement on the BCG in three axes. METHODS: Acceleration was measured using a three-axis accelerometer fastened to the lumbar region of the subject while simultaneous recordings of ECG, and respiratory motion via impedance plethysmography were also made. Data were recorded during a 146-s period of inactivity on the part of the subject during which time there was no contact with the spacecraft. RESULTS: Total body motion due to respiratory activity was consistent with that calculated from the known action of the diaphragm and conservation of momentum. The accelerations due to cardiac activity, ensemble averaged over the R-R interval, were greatest along the head-to-foot axis. Maximum amplitude of the HIJK complex of the BCG generated by ventricular ejection was greatest in the head to foot axis (approximately 70 x 10(-3) m x s(-2)), but there were also substantial accelerations along the dorsoventral axis of up to 43 10(-3) m x s(-2), that are not measured interrestrial two-dimensional studies. The amplitude of the BCG was strongly affected by lung volume, with accelerations being reduced 50 to 70% between end-inspiration and end-expiration. CONCLUSIONS: These data suggest a greatly reduced transmission of the cardiac motion to the body at end-expiration (FRC) than at higher lung volumes. The BCG might be further developed as a non-invasive means of monitoring parameters such as stroke volume in microgravity.

  16. A Brief Review of Non-invasive Monitoring of Respiratory Condition for Extubated Patients with or at Risk for Obstructive Sleep Apnea after Surgery

    PubMed Central

    Zhang, Xuezheng; Kassem, Mahmoud Attia Mohamed; Zhou, Ying; Shabsigh, Muhammad; Wang, Quanguang; Xu, Xuzhong

    2017-01-01

    Obstructive sleep apnea (OSA) is one of the important risk factors contributing to postoperative airway complications. OSA alters the respiratory physiology and increases the sensitivity of muscle tone of the upper airway after surgery to residual anesthetic medication. In addition, the prevalence of OSA was reported to be much higher among surgical patients than the general population. Therefore, appropriate monitoring to detect early respiratory impairment in postoperative extubated patients with possible OSA is challenging. Based on the comprehensive clinical observation, several equipment have been used for monitoring the respiratory conditions of OSA patients after surgery, including the continuous pulse oximetry, capnography, photoplethysmography (PPG), and respiratory volume monitor (RVM). To date, there has been no consensus on the most suitable device as a recommended standard of care. In this review, we describe the advantages and disadvantages of some possible monitoring strategies under certain clinical conditions. According to the literature, the continuous pulse oximetry, with its high sensitivity, is still the most widely used device. It is also cost-effective and convenient to use but has low specificity and does not reflect ventilation. Capnography is the most widely used device for detection of hypoventilation, but it may not provide reliable data for extubated patients. Even normal capnography cannot exclude the existence of hypoxia. PPG shows the state of both ventilation and oxygenation, but its sensitivity needs further improvement. RVM provides real-time detection of hypoventilation, quantitative precise demonstration of respiratory rate, tidal volume, and MV for extubated patients, but no reflection of oxygenation. Altogether, the sole use of any of these devices is not ideal for monitoring of extubated patients with or at risk for OSA after surgery. However, we expect that the combined use of continuous pulse oximetry and RVM may be promising for these patients due to their complementary function, which need further study. PMID:28337439

  17. Use of volume-targeted non-invasive bilevel positive airway pressure ventilation in a patient with amyotrophic lateral sclerosis*,**

    PubMed Central

    Diaz-Abad, Montserrat; Brown, John Edward

    2014-01-01

    Amyotrophic lateral sclerosis (ALS) is a progressive neurodegenerative disease in which most patients die of respiratory failure. Although volume-targeted non-invasive bilevel positive airway pressure (BPAP) ventilation has been studied in patients with chronic respiratory failure of various etiologies, its use in ALS has not been reported. We present the case of a 66-year-old woman with ALS and respiratory failure treated with volume-targeted BPAP ventilation for 15 weeks. Weekly data downloads showed that disease progression was associated with increased respiratory muscle weakness, decreased spontaneous breathing, and increased use of non-invasive positive pressure ventilation, whereas tidal volume and minute ventilation remained relatively constant. PMID:25210968

  18. Remote Patient Monitoring via Non-Invasive Digital Technologies: A Systematic Review

    PubMed Central

    Tran, Melody; Angelaccio, Michele; Arcona, Steve

    2017-01-01

    Abstract Background: We conducted a systematic literature review to identify key trends associated with remote patient monitoring (RPM) via noninvasive digital technologies over the last decade. Materials and Methods: A search was conducted in EMBASE and Ovid MEDLINE. Citations were screened for relevance against predefined selection criteria based on the PICOTS (Population, Intervention, Comparator, Outcomes, Timeframe, and Study Design) format. We included studies published between January 1, 2005 and September 15, 2015 that used RPM via noninvasive digital technology (smartphones/personal digital assistants [PDAs], wearables, biosensors, computerized systems, or multiple components of the formerly mentioned) in evaluating health outcomes compared to standard of care or another technology. Studies were quality appraised according to Critical Appraisal Skills Programme. Results: Of 347 articles identified, 62 met the selection criteria. Most studies were randomized control trials with older adult populations, small sample sizes, and limited follow-up. There was a trend toward multicomponent interventions (n = 26), followed by smartphones/PDAs (n = 12), wearables (n = 11), biosensor devices (n = 7), and computerized systems (n = 6). Another key trend was the monitoring of chronic conditions, including respiratory (23%), weight management (17%), metabolic (18%), and cardiovascular diseases (16%). Although substantial diversity in health-related outcomes was noted, studies predominantly reported positive findings. Conclusions: This review will help decision makers develop a better understanding of the current landscape of peer-reviewed literature, demonstrating the utility of noninvasive RPM in various patient populations. Future research is needed to determine the effectiveness of RPM via noninvasive digital technologies in delivering patient healthcare benefits and the feasibility of large-scale implementation. PMID:27116181

  19. Instrumentation for the analysis of respiratory system disorders during sleep: Design and application

    NASA Astrophysics Data System (ADS)

    de Melo, Pedro Lopes; de Andrade Lemes, Lucas Neves

    2002-11-01

    Sleep breathing disorders are estimated to be present in 2%-4% of middle-aged adults. Serious adverse consequences, such as systemic arterial hypertension, myocardial infraction, and cerebrovascular disease, can be related to these conditions. Intellectual deficits associated with attention, memory, and problem-solving have also been associated with a poor quality of sleep. The main causes of these disorders are obstructions resulting from repetitive narrowing and closure of the pharyngeal airway, which have been monitored by indirect measurements of temperature, displacement, and other highly invasive procedures. The measurement of mechanical impedance of the respiratory system by the forced oscillation technique (FOT) has recently been suggested to quantify the respiratory obstruction during sleep. It is claimed that the noninvasive and dynamic characteristics of this technique would allow a noninvasive and accurate analysis of these events. In spite of this high scientific and clinical potential, there is no detailed description of a complete instrumentation system to implement this promising technique in sleep studies. In this context, the purpose of this study was twofold: (1) describe the development of a new computer-based system for identification of the mechanical impedance of the respiratory system during sleep by the FOT and (2) evaluate the performance of this device in the description of respiratory events in conditions including no, mild, serious disease, and therapeutic procedures. These evaluations confirmed the desirable features achieved in laboratory tests and the high scientific and clinical potential of this system.

  20. Polygraphic respiratory events during sleep with noninvasive ventilation in children: description, prevalence, and clinical consequences.

    PubMed

    Caldarelli, Valeria; Borel, Jean Christian; Khirani, Sonia; Ramirez, Adriana; Cutrera, Renato; Pépin, Jean-Louis; Fauroux, Brigitte

    2013-04-01

    The optimal monitoring during sleep with noninvasive positive pressure ventilation (NPPV) has not been validated in children. The aim of the study was to describe on polygraphic (PG) recordings the respiratory events and associated autonomic arousals (AA) and/or 3 % desaturations (DS3%) during nocturnal NPPV. This was a prospective descriptive study performed in the pulmonology unit of a pediatric university hospital. Consecutive patients admitted for routine follow-up of long-term NPPV were enrolled. Nocturnal PG during sleep with NPPV was performed. A second PG was performed after adjustment of the ventilatory settings when a respiratory event occurred more than 50 times/h. The PG tracings of 39 patients (age range 1-18 years) were analyzed. Underlying diagnoses included neuromuscular disease (n = 13), obstructive sleep apnea (n = 15), and lung disease (n = 11). Unintentional leaks, patient-ventilator asynchronies, decrease in ventilatory drive, upper airway obstruction with or without reduction of ventilatory drive, and mixed events were observed in 27, 33, 10, 11, 12, and 3 % of the patients, respectively. A predominant respiratory event was observed in all patients. The mean duration spent with respiratory events was 32 ± 30 % (range 3-96 %) of total recording time. Unintentional leaks were the most frequently associated with AA, whereas patient-ventilator asynchronies were rarely associated with AA or DS3%. In eight re-evaluated patients, a decrease in the main event was observed (p = 0.005). Respiratory events during sleep with NPPV are common in children treated with long-term NPPV. Consequences of respiratory events vary according to the type of event with unintentional leaks being associated preferentially with AA.

  1. Hot Topics in Noninvasive Ventilation: Report of a Working Group at the International Symposium on Sleep-Disordered Breathing in Leuven, Belgium.

    PubMed

    Vrijsen, Bart; Chatwin, Michelle; Contal, Oliver; Derom, Eric; Janssens, Jean-Paul; Kampelmacher, Mike J; Muir, Jean-Francois; Pinto, Susana; Rabec, Claudio; Ramsay, Michelle; Randerath, Winfried J; Storre, Jan H; Wijkstra, Peter J; Windisch, Wolfram; Testelmans, Dries

    2015-09-01

    During the last few decades, attention has increasingly focused on noninvasive ventilation (NIV) in the treatment of chronic respiratory failure. The University of Leuven and the University Hospitals Leuven therefore chose this topic for a 2-day working group session during their International Symposium on Sleep-Disordered Breathing. Numerous European experts took part in this session and discussed (1) NIV in amyotrophic lateral sclerosis (when to start NIV, NIV and sleep, secretion management, and what to do when NIV fails), (2) recent insights in NIV and COPD (high-intensity NIV, NIV in addition to exercise training, and NIV during exercise training), (3) monitoring of NIV (monitoring devices, built-in ventilator software, leaks, and asynchronies) and identifying events during NIV; and (4) recent and future developments in NIV (target-volume NIV, electromyography-triggered NIV, and autoregulating algorithms). Copyright © 2015 by Daedalus Enterprises.

  2. NIV-Helmet in Severe Hypoxemic Acute Respiratory Failure.

    PubMed

    Martins, Joana; Nunes, P; Silvestre, C; Abadesso, C; Loureiro, H; Almeida, H

    2015-01-01

    Noninvasive ventilation (NIV) is a method to be applied in acute respiratory failure, given the possibility of avoiding tracheal intubation and conventional ventilation. A previous healthy 5-month-old boy developed low-grade intermittent fever, flu-like symptoms, and dry cough for 3 days. On admission, he showed severe respiratory distress with SpO2/FiO2 ratio of 94. Subsequent evaluation identified an RSV infection complicated with an increase of inflammatory parameters (reactive C protein 15 mg/dL). Within the first hour after NIV-helmet CPAP SpO2/FiO2 ratio increased to 157. This sustained improvement allowed the continuing of this strategy. After 102 h, he was disconnected from the helmet CPAP device. The NIV use in severe hypoxemic acute respiratory failure should be carefully monitored as the absence of clinical improvement has a predictive value in the need to resume to intubation and mechanical ventilation. We emphasize that SpO2/FiO2 ratio is a valuable monitoring instrument. Helmet interface use represents a more comfortable alternative for providing ventilatory support, particularly to small infants, which constitute a sensitive group within pediatric patients.

  3. NONINVASIVE DETERMINATION OF RESPIRATORY OZONE ABSORPTION: THE BOLUS-RESPONSE METHOD

    EPA Science Inventory

    Dr. James Ultman and colleagues used a fast-responding ozone measurement system, which they had developed with previous HEI support, to noninvasively measure the absorption of inhaled ozone in different regions of the respiratory tract of healthy adult men. While the subjec...

  4. Solvent-free fabrication of biodegradable hot-film flow sensor for noninvasive respiratory monitoring

    NASA Astrophysics Data System (ADS)

    Dinh, Toan; Phan, Hoang-Phuong; Nguyen, Tuan-Khoa; Qamar, Afzaal; Woodfield, Peter; Zhu, Yong; Nguyen, Nam-Trung; Viet Dao, Dzung

    2017-06-01

    In this paper, we report on a low-cost, environment-friendly and wearable thermal flow sensor, which can be manufactured in-house using pencil graphite as a sensing hot film and biodegradable printing paper as a substrate, without using any toxic solvents or cleanroom facilities. The hot film flow sensor offers excellent performance such as high signal-to-noise ratio (≥slant 40 for an air flow velocity of 1 m s-1), high sensitivity to airflow (53.7 mV(m s-1)-0.8) and outstanding long-term stability (almost no drift in 24 h). The sensor can be comfortably affixed to the philtrum of patients and measures human respiration in realtime. The results indicate that the wearable thermal flow sensors fabricated by this solvent-free and user-friendly method could be employed in human respiratory monitoring.

  5. Inhaled Epoprostenol Through Noninvasive Routes of Ventilator Support Systems.

    PubMed

    Ammar, Mahmoud A; Sasidhar, Madhu; Lam, Simon W

    2018-06-01

    The administration of inhaled epoprostenol (iEPO) through noninvasive routes of ventilator support systems has never been previously evaluated. Describe the use of iEPO when administered through noninvasive routes of ventilator support systems. Critically ill patients admitted to the intensive care unit who received iEPO through noninvasive routes were analyzed. Improvements in respiratory status and hemodynamic parameters were evaluated. Safety end points assessed included hypotension, rebound hypoxemia, significant bleeding, and thrombocytopenia. A total of 36 patients received iEPO through noninvasive routes: high-flow oxygen therapy through nasal cannula, n = 29 (81%) and noninvasive positive-pressure ventilation, n = 7 (19%). Sixteen patients had improvement in their respiratory status: mean decrease in fraction of inspired oxygen (FiO 2 ), 20% ± 13%; mean increase in partial pressure of arterial oxygen to FiO 2 (PaO 2 /FiO 2 ) ratio, 60 ± 50 mm Hg; and mean decrease in HFNC oxygen flow rate, 6 ± 3 liters per minute (LPM). Eight patients had declines in their respiratory status (mean increase in FiO 2 , 30% ± 20%; mean decrease in PaO 2 /FiO 2 ratio, 38 ± 20 mm Hg; and mean increase in HFNC oxygen flow rate, 15 ± 10 LPM), and 12 patients had no change in their respiratory status. Conclusion and Relevance: This represents the first evaluation of the administration of iEPO through noninvasive routes of ventilator support systems and demonstrates that in critically ill patients, iEPO could be administered through a noninvasive route. Further evaluation is needed to determine the extent of benefit with this route of administration.

  6. Detecting Vital Signs with Wearable Wireless Sensors

    PubMed Central

    Yilmaz, Tuba; Foster, Robert; Hao, Yang

    2010-01-01

    The emergence of wireless technologies and advancements in on-body sensor design can enable change in the conventional health-care system, replacing it with wearable health-care systems, centred on the individual. Wearable monitoring systems can provide continuous physiological data, as well as better information regarding the general health of individuals. Thus, such vital-sign monitoring systems will reduce health-care costs by disease prevention and enhance the quality of life with disease management. In this paper, recent progress in non-invasive monitoring technologies for chronic disease management is reviewed. In particular, devices and techniques for monitoring blood pressure, blood glucose levels, cardiac activity and respiratory activity are discussed; in addition, on-body propagation issues for multiple sensors are presented. PMID:22163501

  7. FEV manoeuvre induced changes in breath VOC compositions: an unconventional view on lung function tests

    NASA Astrophysics Data System (ADS)

    Sukul, Pritam; Schubert, Jochen K.; Oertel, Peter; Kamysek, Svend; Taunk, Khushman; Trefz, Phillip; Miekisch, Wolfram

    2016-06-01

    Breath volatile organic compound (VOC) analysis can open a non-invasive window onto pathological and metabolic processes in the body. Decades of clinical breath-gas analysis have revealed that changes in exhaled VOC concentrations are important rather than disease specific biomarkers. As physiological parameters, such as respiratory rate or cardiac output, have profound effects on exhaled VOCs, here we investigated VOC exhalation under respiratory manoeuvres. Breath VOCs were monitored by means of real-time mass-spectrometry during conventional FEV manoeuvres in 50 healthy humans. Simultaneously, we measured respiratory and hemodynamic parameters noninvasively. Tidal volume and minute ventilation increased by 292 and 171% during the manoeuvre. FEV manoeuvre induced substance specific changes in VOC concentrations. pET-CO2 and alveolar isoprene increased by 6 and 21% during maximum exhalation. Then they decreased by 18 and 37% at forced expiration mirroring cardiac output. Acetone concentrations rose by 4.5% despite increasing minute ventilation. Blood-borne furan and dimethyl-sulphide mimicked isoprene profile. Exogenous acetonitrile, sulphides, and most aliphatic and aromatic VOCs changed minimally. Reliable breath tests must avoid forced breathing. As isoprene exhalations mirrored FEV performances, endogenous VOCs might assure quality of lung function tests. Analysis of exhaled VOC concentrations can provide additional information on physiology of respiration and gas exchange.

  8. FEV manoeuvre induced changes in breath VOC compositions: an unconventional view on lung function tests

    PubMed Central

    Sukul, Pritam; Schubert, Jochen K.; Oertel, Peter; Kamysek, Svend; Taunk, Khushman; Trefz, Phillip; Miekisch, Wolfram

    2016-01-01

    Breath volatile organic compound (VOC) analysis can open a non-invasive window onto pathological and metabolic processes in the body. Decades of clinical breath-gas analysis have revealed that changes in exhaled VOC concentrations are important rather than disease specific biomarkers. As physiological parameters, such as respiratory rate or cardiac output, have profound effects on exhaled VOCs, here we investigated VOC exhalation under respiratory manoeuvres. Breath VOCs were monitored by means of real-time mass-spectrometry during conventional FEV manoeuvres in 50 healthy humans. Simultaneously, we measured respiratory and hemodynamic parameters noninvasively. Tidal volume and minute ventilation increased by 292 and 171% during the manoeuvre. FEV manoeuvre induced substance specific changes in VOC concentrations. pET-CO2 and alveolar isoprene increased by 6 and 21% during maximum exhalation. Then they decreased by 18 and 37% at forced expiration mirroring cardiac output. Acetone concentrations rose by 4.5% despite increasing minute ventilation. Blood-borne furan and dimethyl-sulphide mimicked isoprene profile. Exogenous acetonitrile, sulphides, and most aliphatic and aromatic VOCs changed minimally. Reliable breath tests must avoid forced breathing. As isoprene exhalations mirrored FEV performances, endogenous VOCs might assure quality of lung function tests. Analysis of exhaled VOC concentrations can provide additional information on physiology of respiration and gas exchange. PMID:27311826

  9. Availability and performance of image/video-based vital signs monitoring methods: a systematic review protocol.

    PubMed

    Harford, Mirae; Catherall, Jacqueline; Gerry, Stephen; Young, Duncan; Watkinson, Peter

    2017-10-25

    For many vital signs, monitoring methods require contact with the patient and/or are invasive in nature. There is increasing interest in developing still and video image-guided monitoring methods that are non-contact and non-invasive. We will undertake a systematic review of still and video image-based monitoring methods. We will perform searches in multiple databases which include MEDLINE, Embase, CINAHL, Cochrane library, IEEE Xplore and ACM Digital Library. We will use OpenGrey and Google searches to access unpublished or commercial data. We will not use language or publication date restrictions. The primary goal is to summarise current image-based vital signs monitoring methods, limited to heart rate, respiratory rate, oxygen saturations and blood pressure. Of particular interest will be the effectiveness of image-based methods compared to reference devices. Other outcomes of interest include the quality of the method comparison studies with respect to published reporting guidelines, any limitations of non-contact non-invasive technology and application in different populations. To the best of our knowledge, this is the first systematic review of image-based non-contact methods of vital signs monitoring. Synthesis of currently available technology will facilitate future research in this highly topical area. PROSPERO CRD42016029167.

  10. A Non-Invasive Multichannel Hybrid Fiber-Optic Sensor System for Vital Sign Monitoring

    PubMed Central

    Fajkus, Marcel; Nedoma, Jan; Martinek, Radek; Vasinek, Vladimir; Nazeran, Homer; Siska, Petr

    2017-01-01

    In this article, we briefly describe the design, construction, and functional verification of a hybrid multichannel fiber-optic sensor system for basic vital sign monitoring. This sensor uses a novel non-invasive measurement probe based on the fiber Bragg grating (FBG). The probe is composed of two FBGs encapsulated inside a polydimethylsiloxane polymer (PDMS). The PDMS is non-reactive to human skin and resistant to electromagnetic waves, UV absorption, and radiation. We emphasize the construction of the probe to be specifically used for basic vital sign monitoring such as body temperature, respiratory rate and heart rate. The proposed sensor system can continuously process incoming signals from up to 128 individuals. We first present the overall design of this novel multichannel sensor and then elaborate on how it has the potential to simplify vital sign monitoring and consequently improve the comfort level of patients in long-term health care facilities, hospitals and clinics. The reference ECG signal was acquired with the use of standard gel electrodes fixed to the monitored person’s chest using a real-time monitoring system for ECG signals with virtual instrumentation. The outcomes of these experiments have unambiguously proved the functionality of the sensor system and will be used to inform our future research in this fast developing and emerging field. PMID:28075341

  11. Noninvasive ventilation in stable hypercapnic COPD: what is the evidence?

    PubMed Central

    Duiverman, Marieke L.

    2018-01-01

    Long-term noninvasive ventilation (NIV) to treat chronic hypercapnic respiratory failure is still controversial in severe chronic obstructive pulmonary disease (COPD) patients. However, with the introduction of high-intensity NIV, important benefits from this therapy have also been shown in COPD. In this review, the focus will be on the arguments for long-term NIV at home in patients with COPD. The rise of (high-intensity) NIV in COPD and the randomised controlled trials showing positive effects with this mode of ventilation will be discussed. Finally, the challenges that might be encountered (both in clinical practice and in research) in further optimising this therapy, monitoring and following patients, and selecting the patients who might benefit most will be reviewed. PMID:29637078

  12. Polyvinylidene fluoride film based nasal sensor to monitor human respiration pattern: an initial clinical study.

    PubMed

    Roopa Manjunatha, G; Rajanna, K; Mahapatra, D Roy; Nayak, M M; Krishnaswamy, Uma Maheswari; Srinivasa, R

    2013-12-01

    Design and development of a piezoelectric polyvinylidene fluoride (PVDF) thin film based nasal sensor to monitor human respiration pattern (RP) from each nostril simultaneously is presented in this paper. Thin film based PVDF nasal sensor is designed in a cantilever beam configuration. Two cantilevers are mounted on a spectacle frame in such a way that the air flow from each nostril impinges on this sensor causing bending of the cantilever beams. Voltage signal produced due to air flow induced dynamic piezoelectric effect produce a respective RP. A group of 23 healthy awake human subjects are studied. The RP in terms of respiratory rate (RR) and Respiratory air-flow changes/alterations obtained from the developed PVDF nasal sensor are compared with RP obtained from respiratory inductance plethysmograph (RIP) device. The mean RR of the developed nasal sensor (19.65 ± 4.1) and the RIP (19.57 ± 4.1) are found to be almost same (difference not significant, p > 0.05) with the correlation coefficient 0.96, p < 0.0001. It was observed that any change/alterations in the pattern of RIP is followed by same amount of change/alterations in the pattern of PVDF nasal sensor with k = 0.815 indicating strong agreement between the PVDF nasal sensor and RIP respiratory air-flow pattern. The developed sensor is simple in design, non-invasive, patient friendly and hence shows promising routine clinical usage. The preliminary result shows that this new method can have various applications in respiratory monitoring and diagnosis.

  13. Effect of Noninvasive Ventilation vs Oxygen Therapy on Mortality Among Immunocompromised Patients With Acute Respiratory Failure: A Randomized Clinical Trial.

    PubMed

    Lemiale, Virginie; Mokart, Djamel; Resche-Rigon, Matthieu; Pène, Frédéric; Mayaux, Julien; Faucher, Etienne; Nyunga, Martine; Girault, Christophe; Perez, Pierre; Guitton, Christophe; Ekpe, Kenneth; Kouatchet, Achille; Théodose, Igor; Benoit, Dominique; Canet, Emmanuel; Barbier, François; Rabbat, Antoine; Bruneel, Fabrice; Vincent, Francois; Klouche, Kada; Loay, Kontar; Mariotte, Eric; Bouadma, Lila; Moreau, Anne-Sophie; Seguin, Amélie; Meert, Anne-Pascale; Reignier, Jean; Papazian, Laurent; Mehzari, Ilham; Cohen, Yves; Schenck, Maleka; Hamidfar, Rebecca; Darmon, Michael; Demoule, Alexandre; Chevret, Sylvie; Azoulay, Elie

    2015-10-27

    Noninvasive ventilation has been recommended to decrease mortality among immunocompromised patients with hypoxemic acute respiratory failure. However, its effectiveness for this indication remains unclear. To determine whether early noninvasive ventilation improved survival in immunocompromised patients with nonhypercapnic acute hypoxemic respiratory failure. Multicenter randomized trial conducted among 374 critically ill immunocompromised patients, of whom 317 (84.7%) were receiving treatment for hematologic malignancies or solid tumors, at 28 intensive care units (ICUs) in France and Belgium between August 12, 2013, and January 2, 2015. Patients were randomly assigned to early noninvasive ventilation (n = 191) or oxygen therapy alone (n = 183). The primary outcome was day-28 mortality. Secondary outcomes were intubation, Sequential Organ Failure Assessment score on day 3, ICU-acquired infections, duration of mechanical ventilation, and ICU length of stay. At randomization, median oxygen flow was 9 L/min (interquartile range, 5-15) in the noninvasive ventilation group and 9 L/min (interquartile range, 6-15) in the oxygen group. All patients in the noninvasive ventilation group received the first noninvasive ventilation session immediately after randomization. On day 28 after randomization, 46 deaths (24.1%) had occurred in the noninvasive ventilation group vs 50 (27.3%) in the oxygen group (absolute difference, -3.2 [95% CI, -12.1 to 5.6]; P = .47). Oxygenation failure occurred in 155 patients overall (41.4%), 73 (38.2%) in the noninvasive ventilation group and 82 (44.8%) in the oxygen group (absolute difference, -6.6 [95% CI, -16.6 to 3.4]; P = .20). There were no significant differences in ICU-acquired infections, duration of mechanical ventilation, or lengths of ICU or hospital stays. Among immunocompromised patients admitted to the ICU with hypoxemic acute respiratory failure, early noninvasive ventilation compared with oxygen therapy alone did not reduce 28-day mortality. However, study power was limited. clinicaltrials.gov Identifier: NCT01915719.

  14. The use of CT density changes at internal tissue interfaces to correlate internal organ motion with an external surrogate

    NASA Astrophysics Data System (ADS)

    Gaede, Stewart; Carnes, Gregory; Yu, Edward; Van Dyk, Jake; Battista, Jerry; Lee, Ting-Yim

    2009-01-01

    The purpose of this paper is to describe a non-invasive method to monitor the motion of internal organs affected by respiration without using external markers or spirometry, to test the correlation with external markers, and to calculate any time shift between the datasets. Ten lung cancer patients were CT scanned with a GE LightSpeed Plus 4-Slice CT scanner operating in a ciné mode. We retrospectively reconstructed the raw CT data to obtain consecutive 0.5 s reconstructions at 0.1 s intervals to increase image sampling. We defined regions of interest containing tissue interfaces, including tumour/lung interfaces that move due to breathing on multiple axial slices and measured the mean CT number versus respiratory phase. Tumour motion was directly correlated with external marker motion, acquired simultaneously, using the sample coefficient of determination, r2. Only three of the ten patients showed correlation higher than r2 = 0.80 between tumour motion and external marker position. However, after taking into account time shifts (ranging between 0 s and 0.4 s) between the two data sets, all ten patients showed correlation better than r2 = 0.8. This non-invasive method for monitoring the motion of internal organs is an effective tool that can assess the use of external markers for 4D-CT imaging and respiratory-gated radiotherapy on a patient-specific basis.

  15. The use of CT density changes at internal tissue interfaces to correlate internal organ motion with an external surrogate.

    PubMed

    Gaede, Stewart; Carnes, Gregory; Yu, Edward; Van Dyk, Jake; Battista, Jerry; Lee, Ting-Yim

    2009-01-21

    The purpose of this paper is to describe a non-invasive method to monitor the motion of internal organs affected by respiration without using external markers or spirometry, to test the correlation with external markers, and to calculate any time shift between the datasets. Ten lung cancer patients were CT scanned with a GE LightSpeed Plus 4-Slice CT scanner operating in a ciné mode. We retrospectively reconstructed the raw CT data to obtain consecutive 0.5 s reconstructions at 0.1 s intervals to increase image sampling. We defined regions of interest containing tissue interfaces, including tumour/lung interfaces that move due to breathing on multiple axial slices and measured the mean CT number versus respiratory phase. Tumour motion was directly correlated with external marker motion, acquired simultaneously, using the sample coefficient of determination, r(2). Only three of the ten patients showed correlation higher than r(2) = 0.80 between tumour motion and external marker position. However, after taking into account time shifts (ranging between 0 s and 0.4 s) between the two data sets, all ten patients showed correlation better than r(2) = 0.8. This non-invasive method for monitoring the motion of internal organs is an effective tool that can assess the use of external markers for 4D-CT imaging and respiratory-gated radiotherapy on a patient-specific basis.

  16. Hypercapnic encephalopathy syndrome: a new frontier for non-invasive ventilation?

    PubMed

    Scala, Raffaele

    2011-08-01

    According to the classical international guidelines, non-invasive ventilation is contraindicated in hypercapnic encephalopathy syndrome (HES) due to the poor compliance to ventilatory treatment of confused/agitated patients and the risk of aspirative pneumonia related to lack of airways protection. As a matter of fact, conventional mechanical ventilation has been recommended as "golden standard" in these patients. However, up to now there are not controlled data that have demonstrated in HES the advantage of conventional mechanical ventilation vs non-invasive ventilation. In fact, patients with altered mental status have been systematically excluded from the randomised and controlled trials performed with non-invasive ventilation in hypercapnic acute respiratory failure. Recent studies have clearly demonstrated that an initial cautious NPPV trial in selected HES patients may be attempt as long as there are no other contraindications and the technique is provided by experienced caregivers in a closely monitored setting where ETI is always readily available. The purpose of this review is to report the physiologic rationale, the clinical feasibility and the still open questions about the careful use of non-invasive ventilation in HES as first-line ventilatory strategy in place of conventional mechanical ventilation via endotracheal intubation. Copyright © 2011 Elsevier Ltd. All rights reserved.

  17. Availability, fermentability, and energy value of resistant maltodextrin: modeling of short-term indirect calorimetric measurements in healthy adults.

    PubMed

    Goda, Toshinao; Kajiya, Yuya; Suruga, Kazuhito; Tagami, Hiroyuki; Livesey, Geoffrey

    2006-06-01

    Determination of the metabolizable (ME) and net metabolizable (NME) energy of total carbohydrate requires estimation of its available (AC) and fermentable (FC) carbohydrate content. Modeling of indirect calorimetric observations (respiratory gas exchange) and breath hydrogen would appear to make it possible to estimate noninvasively these nutritional quantities and the approximate time-course of availability. We assessed the time-course of metabolism and energy availability from resistant maltodextrin (RMD) by modeling of respiratory gases after a single oral dose. Seventeen healthy adults (13 M, 4 F; aged 25-46 y) were randomly assigned to treatments (water, maltodextrin, or RMD) in a multiple-crossover, single-blinded trial with > or = 7 d washout. We monitored 8-h nitrogen-corrected oxygen and carbon dioxide exchanges and breath hydrogen. All treatment groups took low-carbohydrate meals at 3 and 6 h. Indirect calorimetry alone provided only qualitative information about the nutritional values of carbohydrate. In contrast, modeling of gaseous exchanges along with the use of central assumptions showed that 17 +/- 2% of RMD was AC and 40 +/- 4% was FC. As compared with 17 kJ gross energy/g RMD, mean (+/- SE) energy values were 7.3 +/- 0.6 kJ ME/g and 6.3 +/- 0.5 kJ NME/g. The fiber fraction of RMD provided 5.2 +/- 0.7 kJ ME/g and 4.1 +/- 0.6 kJ NME/g. Modeling with the use of this noninvasive and widely available respiratory gas-monitoring technique yields nutritional values for carbohydrate that are supported by enzymatic, microbial, and animal studies and human fecal collection studies. Improvement in this approach is likely and testable across laboratories.

  18. Noninvasive optical monitoring multiple physiological parameters response to cytokine storm

    NASA Astrophysics Data System (ADS)

    Li, Zebin; Li, Ting

    2018-02-01

    Cancer and other disease originated by immune or genetic problems have become a main cause of death. Gene/cell therapy is a highlighted potential method for the treatment of these diseases. However, during the treatment, it always causes cytokine storm, which probably trigger acute respiratory distress syndrome and multiple organ failure. Here we developed a point-of-care device for noninvasive monitoring cytokine storm induced multiple physiological parameters simultaneously. Oxy-hemoglobin, deoxy-hemoglobin, water concentration and deep-tissue/tumor temperature variations were simultaneously measured by extended near infrared spectroscopy. Detection algorithms of symptoms such as shock, edema, deep-tissue fever and tissue fibrosis were developed and included. Based on these measurements, modeling of patient tolerance and cytokine storm intensity were carried out. This custom device was tested on patients experiencing cytokine storm in intensive care unit. The preliminary data indicated the potential of our device in popular and milestone gene/cell therapy, especially, chimeric antigen receptor T-cell immunotherapy (CAR-T).

  19. Tracheobronchomegaly associated tracheomalacia: analysis by sleep study.

    PubMed

    Sundaram, P; Joshi, J M

    2004-01-01

    Tracheobronchomegaly (TBM) occasionally may progress to extensive tracheomalacia which leads to respiratory failure. Spirometry, dynamic expiratory multidetector computed tomography (CT), bronchoscopy are used to diagnose patients of suspected tracheobronchomalacia. We used the technique of night-time monitoring of respiratory variables to show the presence of respiratory abnormalities during sleep and which was corrected by applying nasal continuous positive airway pressure (CPAP). The study showed the presence of both apnoea and hypopnoeas, which were obstructive in nature with an apnoea-hypopnoea index (AHI) of 11, no snoring and associated oxygen desaturation of 75 per cent. A second overnight study with nasal continuous positive airway pressure at a critical pressure of 8 cm, the AHI decreased to 3 along with no drop in oxygen saturation. This non-invasive technique should be considered as a diagnostic tool in tracheobronchomalacia and to know the outcome of CPAP, surgical or stent therapy in this condition.

  20. [Anesthetic care for fibrobronchoscopy in patients with chronic terminal respiratory insufficiency undergoing evaluation for isolated lung transplantation].

    PubMed

    Solca, M; Elena, A; Croci, M; Damia, G

    1993-01-01

    During the first 18 month operation of the isolated lung transplantation program at or Institution, eight patients with terminal chronic respiratory failure underwent fiberoptic bronchoscopy and broncho-alveolar lavage as part of their evaluation for isolated lung transplantation. Four patients had severe obstructive, three restrictive, and one mixed, obstructive and restrictive, disease; all of them were on continuous supplemental oxygen. Procedures were performed under topical anaesthesia, with either light sedation or simple monitored anaesthesia care. Monitoring included non-invasive blood pressure measurement, pulse oximeter and precordial stethoscope. No adverse events were recorded, except in one case, when pulse oximeter reading precipitously dropped below 80%, to a minimum of 68-69%. The procedures was terminated short of its completion, and the patient was briefly assisted with manual bag ventilation on oxygen 100%. Pulse oximeter quickly returned to normal levels (above 90%), and the patient promptly recovered, without complications. The importance of monitored anaesthesia care during fiberoptic bronchoscopy (a usually benign procedure) in critically ill patients is greatly emphasized.

  1. [Statement of the Association of Pneumological Clinics and the German Respiratory Society on the coding of invasive and non-invasive ventilation in intensity care].

    PubMed

    2013-07-01

    Mechanical ventilation in patients with respiratory failure represents one of the most important aspects of intensity care. It can be performed invasively and non-invasively depending on the clinical situation and the underlying disease. The expenditure and consumption of resources is the basis of the compensation for each patient case in the German diagnosis related group system. For ventilated patients it is calculated based on the hours of ventilation, according to the standard coding guideline. In this statement, the German Respiratory Society and the Association of Pneumological Clinics aim to clarify some aspects of the coding of invasive and non-invasive ventilation. © Georg Thieme Verlag KG Stuttgart · New York.

  2. Challenges on non-invasive ventilation to treat acute respiratory failure in the elderly.

    PubMed

    Scala, Raffaele

    2016-11-15

    Acute respiratory failure is a frequent complication in elderly patients especially if suffering from chronic cardio-pulmonary diseases. Non-invasive mechanical ventilation constitutes a successful therapeutic tool in the elderly as, like in younger patients, it is able to prevent endotracheal intubation in a wide range of acute conditions; moreover, this ventilator technique is largely applied in the elderly in whom invasive mechanical ventilation is considered not appropriated. Furthermore, the integration of new technological devices, ethical issues and environment of treatment are still largely debated in the treatment of acute respiratory failure in the elderly.This review aims at reporting and critically analyzing the peculiarities in the management of acute respiratory failure in elderly people, the role of noninvasive mechanical ventilation, the potential advantages of applying alternative or integrated therapeutic tools (i.e. high-flow nasal cannula oxygen therapy, non-invasive and invasive cough assist devices and low-flow carbon-dioxide extracorporeal systems), drawbacks in physician's communication and "end of life" decisions. As several areas of this topic are not supported by evidence-based data, this report takes in account also "real-life" data as well as author's experience.The choice of the setting and of the timing of non-invasive mechanical ventilation in elderly people with advanced cardiopulmonary disease should be carefully evaluated together with the chance of using integrated or alternative supportive devices. Last but not least, economic and ethical issues may often challenges the behavior of the physicians towards elderly people who are hospitalized for acute respiratory failure at the end stage of their cardiopulmonary and neoplastic diseases.

  3. A noncontact RF-based respiratory sensor: results of a clinical trial.

    PubMed

    Madsen, Spence; Baczuk, Jordan; Thorup, Kurt; Barton, Richard; Patwari, Neal; Langell, John T

    2016-06-01

    Respiratory rate (RR) is a critical vital signs monitored in health care setting. Current monitors suffer from sensor-contact failure, inaccurate data, and limited patient mobility. There is a critical need for an accurate and reliable and noncontact system to monitor RR. We developed a contact-free radio frequency (RF)-based system that measures movement using WiFi signal diffraction, which is converted into interpretable data using a Fourier transform. Here, we investigate the system's ability to measure fine movements associated with human respiration. Testing was conducted on subjects using visual cue, fixed-tempo instruction to breath at standard RRs. Blinded instruction-based RRs were compared to RF-acquired data to determine measurement accuracy. The RF-based technology was studied on postoperative ventilator-dependent patients. Blinded ventilator capnographic RR data were collected for each patient and compared to RF-acquired data to determine measurement accuracy. Respiratory rate data collected from 10 subjects breathing at a fixed RR (14, 16, 18, or 20) demonstrated 95.5% measurement accuracy between the patient's actual rate and that measured by our RF technology. Ten patients were enrolled into the clinical trial. Blinded ventilator capnographic RR data were compared to RF-based acquired data. The RF-based data showed 88.8% measurement accuracy with ventilator capnography. Initial clinical pilot trials with our contact-free RF-based monitoring system demonstrate a high degree of RR measurement accuracy when compared to capnographic data. Based on these results, we believe RF-based systems present a promising noninvasive, inexpensive, and accurate tool for continuous RR monitoring. Copyright © 2016 Elsevier Inc. All rights reserved.

  4. Non-invasive assessment of respiratory muscle function and its relationship to exercise tolerance in patients with chronic obstructive pulmonary disease.

    PubMed

    Chlumský, J; Filipova, P; Terl, M

    2006-01-01

    Most patients with chronic obstructive pulmonary disease (COPD) have impaired respiratory muscle function. Maximal oesophageal pressure correlates closely with exercise tolerance and seems to predict the distance walked during the 6-min walk test. This study assessed the non-invasive parameters of respiratory muscle function in 41 patients with COPD to investigate their relationship to pulmonary function tests and exercise tolerance. The COPD patients, who demonstrated the full range of airway obstruction severity, had a mean forced expiratory volume in 1 s of 42.5% predicted (range, 20 - 79% predicted). Both the maximal inspiratory muscle strength and non-invasive tension-time index were significantly correlated with the degree of lung hyperinflation, as expressed by the ratio of residual volume to total lung capacity, and the distance walked in 6 min. We conclude that respiratory muscle function was influenced mainly by lung hyperinflation and that it had an important effect on exercise tolerance in COPD patients.

  5. Prone positioning in the patient who has acute respiratory distress syndrome: the art and science.

    PubMed

    Vollman, Kathleen M

    2004-09-01

    Acute respiratory distress syndrome (ARDS) remains a significant contributor to the morbidity and mortality of patients in the ICU. A variety of treatments are used to support the lung of the patient who has ARDS and improve gas exchange during the acute injury phase. It seems, however, that the simple, safe, and noninvasive act of prone positioning of the critically ill patient who has ARDS may improve gas exchange while preventing potential complications of high positive end-expiratory pressure, volutrauma, and oxygen toxicity. This article provides the critical care nurse with the physiologic rationale for use of the prone position, indications and contraindications for use, safe strategies for prone positioning, and care techniques and monitoring methods of the patient who is in the prone position.

  6. Laryngeal closure impedes non-invasive ventilation at birth

    PubMed Central

    Crawshaw, Jessica R; Kitchen, Marcus J; Binder-Heschl, Corinna; Thio, Marta; Wallace, Megan J; Kerr, Lauren T; Roehr, Charles C; Lee, Katie L; Buckley, Genevieve A; Davis, Peter G; Flemmer, Andreas; te Pas, Arjan B; Hooper, Stuart B

    2018-01-01

    Background Non-invasive ventilation is sometimes unable to provide the respiratory needs of very premature infants in the delivery room. While airway obstruction is thought to be the main problem, the site of obstruction is unknown. We investigated whether closure of the larynx and epiglottis is a major site of airway obstruction. Methods We used phase contrast X-ray imaging to visualise laryngeal function in spontaneously breathing premature rabbits immediately after birth and at approximately 1 hour after birth. Non-invasive respiratory support was applied via a facemask and images were analysed to determine the percentage of the time the glottis and the epiglottis were open. Hypothesis Immediately after birth, the larynx is predominantly closed, only opening briefly during a breath, making non-invasive intermittent positive pressure ventilation (iPPV) ineffective, whereas after lung aeration, the larynx is predominantly open allowing non-invasive iPPV to ventilate the lung. Results The larynx and epiglottis were predominantly closed (open 25.5%±1.1% and 17.1%±1.6% of the time, respectively) in pups with unaerated lungs and unstable breathing patterns immediately after birth. In contrast, the larynx and the epiglottis were mostly open (90.5%±1.9% and 72.3%±2.3% of the time, respectively) in pups with aerated lungs and stable breathing patterns irrespective of time after birth. Conclusion Laryngeal closure impedes non-invasive iPPV at birth and may reduce the effectiveness of non-invasive respiratory support in premature infants immediately after birth. PMID:29054974

  7. Management of Acute Respiratory Failure in the Patient with Sepsis or Septic Shock.

    PubMed

    Moore, Sarah; Weiss, Brian; Pascual, Jose L; Kaplan, Lewis J

    Sepsis and septic shock are each commonly accompanied by acute respiratory failure and the need for invasive as well as non-invasive ventilation throughout a patient's intensive care unit course. We explore the underpinnings of acute respiratory failure of pulmonary as well as non-pulmonary origin in the context of invasive and non-invasive management approaches. Both pharmacologic and non-pharmacologic adjuncts to ventilatory and oxygenation support are highlighted as well. Finally, rescue modalities are positioned within the intensivist's armamentarium for global care of support of the critically ill or injured patient with sepsis or septic shock.

  8. The effects of non-invasive respiratory support on oropharyngeal temperature and humidity: a neonatal manikin study.

    PubMed

    Roberts, Calum T; Kortekaas, Rebecca; Dawson, Jennifer A; Manley, Brett J; Owen, Louise S; Davis, Peter G

    2016-05-01

    Heating and humidification of inspired gases is routine during neonatal non-invasive respiratory support. However, little is known about the temperature and humidity delivered to the upper airway. The International Standards Organization (ISO) specifies that for all patients with an artificial airway humidifiers should deliver ≥33 g/m(3) absolute humidity (AH). We assessed the oropharyngeal temperature and humidity during different non-invasive support modes in a neonatal manikin study. Six different modes of non-invasive respiratory support were applied at clinically relevant settings to a neonatal manikin, placed in a warmed and humidified neonatal incubator. Oropharyngeal temperature and relative humidity (RH) were assessed using a thermohygrometer. AH was subsequently calculated. Measured temperature and RH varied between devices. Bubble and ventilator continuous positive airway pressure (CPAP) produced temperatures >34°C and AH >38 g/m(3). Variable flow CPAP resulted in lower levels of AH than bubble or ventilator CPAP, and AH decreased with higher gas flow. High-flow (HF) therapy delivered by Optiflow Junior produced higher AH with higher gas flow, whereas with Vapotherm HF the converse was true. Different non-invasive devices deliver inspiratory gases of variable temperature and humidity. Most AH levels were above the ISO recommendation; however, with some HF and variable flow CPAP devices at higher gas flow this was not achieved. Clinicians should be aware of differences in the efficacy of heating and humidification when choosing modes of non-invasive respiratory support. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  9. Analysis and comparison of the effects of N-BiPAP and Bubble-CPAP in treatment of preterm newborns with the weight of below 1500 grams affiliated with respiratory distress syndrome: A randomised clinical trial.

    PubMed

    Sadeghnia, Alireza; Barekateyn, Behzad; Badiei, Zohre; Hosseini, Seyyed Mohsen

    2016-01-01

    Nowadays, establishment of nCPAP and surfactant administration is considered to be the first level of intervention for newborns engaged in the process of Respiratory Distress Syndrome (RDS). In order to decrease the side effects of the nCPAP management placed in noninvasive-non-cycled respiratory support. Noninvasive-cycled respiratory support mechanism have been developed such as N-BiPAP. Therefore, we compared N-BiPAP with Bubble-CPAP in a clinical trial. This research was done as an on newborns weighing less than 1500 grams affiliated with RDS. A3 The total number of newborns was 70. Newborns were divided into two groups with the sample size of 35 patients in each, according to odd and even document numbers. One group was treated with N-BiPAP and the other with Bubble-CPAP. Patients were compared according to the length of treatment with noninvasive respiratory support, length of oxygen intake, number of surfactant doses administered, need for invasive mechanical ventilation, apnea, patent ductus arteriosus (PDA), chronic lung disease, intraventricular hemorrhage, pneumothorax, and death. Data was recorded and compared. The average duration for noninvasive respiratory support and the average time of need to complementary oxygen was not significantly different in both groups (P value > 0.05). Need for invasive ventilation, also chronic lung disease, intraventricular hemorrhage (IVH), pneumothorax, need for the next dose of surfactant, and the death rate did also have no meaningful difference. (P value > 0.05). In this research N-BiPAP did not show any obvious clinical preference over the Bubble-CPAP in treatment of newborns weighing less than 1500 grams and affiliated with RDS.

  10. Early diagnosis of asthma in young children by using non-invasive biomarkers of airway inflammation and early lung function measurements: study protocol of a case-control study

    PubMed Central

    van de Kant, Kim DG; Klaassen, Ester MM; Jöbsis, Quirijn; Nijhuis, Annedien J; van Schayck, Onno CP; Dompeling, Edward

    2009-01-01

    Background Asthma is the most common chronic disease in childhood, characterized by chronic airway inflammation. There are problems with the diagnosis of asthma in young children since the majority of the children with recurrent asthma-like symptoms is symptom free at 6 years, and does not have asthma. With the conventional diagnostic tools it is not possible to differentiate between preschool children with transient symptoms and children with asthma. The analysis of biomarkers of airway inflammation in exhaled breath is a non-invasive and promising technique to diagnose asthma and monitor inflammation in young children. Moreover, relatively new lung function tests (airway resistance using the interrupter technique) have become available for young children. The primary objective of the ADEM study (Asthma DEtection and Monitoring study), is to develop a non-invasive instrument for an early asthma diagnosis in young children, using exhaled inflammatory markers and early lung function measurements. In addition, aetiological factors, including gene polymorphisms and gene expression profiles, in relation to the development of asthma are studied. Methods/design A prospective case-control study is started in 200 children with recurrent respiratory symptoms and 50 control subjects without respiratory symptoms. At 6 years, a definite diagnosis of asthma is made (primary outcome measure) on basis of lung function assessments and current respiratory symptoms ('golden standard'). From inclusion until the definite asthma diagnosis, repeated measurements of lung function tests and inflammatory markers in exhaled breath (condensate), blood and faeces are performed. The study is registered and ethically approved. Discussion This article describes the study protocol of the ADEM study. The new diagnostic techniques applied in this study could make an early diagnosis of asthma possible. An early and reliable asthma diagnosis at 2–3 years will have consequences for the management of the large group of young children with asthma-like symptoms. It will avoid both over-treatment of children with transient wheeze and under-treatment of children with asthma. This might have a beneficial influence on the prognosis of asthma in these young children. Besides, insight into the pathophysiology and aetiology of asthma will be obtained. TRIAL REGISTRATION This study is registered by clinicaltrials.gov (NCT00422747). PMID:19563637

  11. Respiratory monitoring by inductive plethysmography in unrestrained subjects using position sensor-adjusted calibration.

    PubMed

    Brüllmann, Gregor; Fritsch, Karsten; Thurnheer, Robert; Bloch, Konrad E

    2010-01-01

    Portable respiratory inductive plethysmography (RIP) is promising for noninvasive monitoring of breathing patterns in unrestrained subjects. However, its use has been hampered by requiring recalibration after changes in body position. To facilitate RIP application in unrestrained subjects, we developed a technique for adjustment of RIP calibration using position sensor feedback. Five healthy subjects and 12 patients with lung disease were monitored by portable RIP with sensors incorporated within a body garment. Unrestrained individuals were studied during 40-60 min while supine, sitting and upright/walking. Position was changed repeatedly every 5-10 min. Initial qualitative diagnostic calibration followed by volume scaling in absolute units during 20 breaths in different positions by flow meter provided position-specific volume-motion coefficients for RIP. These were applied during subsequent monitoring in corresponding positions according to feedback from 4 accelerometers placed at the chest and thigh. Accuracy of RIP was evaluated by face mask pneumotachography. Position sensor feedback allowed accurate adjustment of RIP calibration during repeated position changes in subjects and patients as reflected in a minor mean difference (bias) in breath-by-breath tidal volumes estimated by RIP and flow meter of 0.02 liters (not significant) and limits of agreement (+/-2 SD) of +/-19% (2,917 comparisons). An average of 10 breaths improved precision of RIP (limits of agreement +/-14%). RIP calibration incorporating position sensor feedback greatly enhances the application of RIP as a valuable, unobtrusive tool to investigate respiratory physiology and ventilatory limitation in unrestrained healthy subjects and patients with lung disease during everyday activities including position changes. Copyright 2009 S. Karger AG, Basel.

  12. A portable respiratory rate estimation system with a passive single-lead electrocardiogram acquisition module.

    PubMed

    Nayan, Nazrul Anuar; Risman, Nur Sabrina; Jaafar, Rosmina

    2016-07-27

    Among vital signs of acutely ill hospital patients, respiratory rate (RR) is a highly accurate predictor of health deterioration. This study proposes a system that consists of a passive and non-invasive single-lead electrocardiogram (ECG) acquisition module and an ECG-derived respiratory (EDR) algorithm in the working prototype of a mobile application. Before estimating RR that produces the EDR rate, ECG signals were evaluated based on the signal quality index (SQI). The SQI algorithm was validated quantitatively using the PhysioNet/Computing in Cardiology Challenge 2011 training data set. The RR extraction algorithm was validated by adopting 40 MIT PhysioNet Multiparameter Intelligent Monitoring in Intensive Care II data set. The estimated RR showed a mean absolute error (MAE) of 1.4 compared with the ``gold standard'' RR. The proposed system was used to record 20 ECGs of healthy subjects and obtained the estimated RR with MAE of 0.7 bpm. Results indicate that the proposed hardware and algorithm could replace the manual counting method, uncomfortable nasal airflow sensor, chest band, and impedance pneumotachography often used in hospitals. The system also takes advantage of the prevalence of smartphone usage and increase the monitoring frequency of the current ECG of patients with critical illnesses.

  13. Time of non-invasive ventilation.

    PubMed

    Nava, Stefano; Navalesi, Paolo; Conti, Giorgio

    2006-03-01

    Non-invasive ventilation (NIV) is a safe, versatile and effective technique that can avert side effects and complications associated with endotracheal intubation. The success of NIV relies on several factors, including the type and severity of acute respiratory failure, the underlying disease, the location of treatment, and the experience of the team. The time factor is also important. NIV is primarily used to avert the need for endotracheal intubation in patients with early-stage acute respiratory failure and post-extubation respiratory failure. It can also be used as an alternative to invasive ventilation at a more advanced stage of acute respiratory failure or to facilitate the process of weaning from mechanical ventilation. NIV has been used to prevent development of acute respiratory failure or post-extubation respiratory failure. The number of days of NIV and hours of daily use differ, depending on the severity and course of the acute respiratory failure and the timing of application. In this review article, we analyse, compare and discuss the results of studies in which NIV was applied at various times during the evolution of acute respiratory failure.

  14. [Update on the respiratory management of patients with chronic neuromuscular disease].

    PubMed

    Priou, P; Trzepizur, W; Meslier, N; Gagnadoux, F

    2017-12-01

    Neuromuscular diseases include a wide range of conditions that may involve potentially life-threatening respiratory complications (infection, respiratory failure). For patients with neuromuscular diseases, clinical assessment of respiratory function and regular pulmonary function tests are needed to screen for nocturnal respiratory disorders, weakness of the diaphragm and potential restrictive disorders and/or chronic hypercapnic respiratory insufficiency, possibly with couch deficiency. MANAGEMENT OF NOCTURNAL RESPIRATORY DISORDERS AND CHRONIC RESPIRATORY FAILURE: Nocturnal respiratory assistance is an important phase of care for nocturnal respiratory disorders and chronic respiratory failure. This may involve continuous positive airway pressure, adaptative servo-ventilation or non-invasive ventilation with a facial or nasal mask. As needed, diurnal assistance may be proposed by mouthpiece ventilation. Should non-invasive ventilation prove insufficient, or if significant swallowing disorders or recurrent bronchial obstruction develop, or in case of prolonged intubation, tracheotomy may be required. In case of lower airway infection with ineffective cough, physical therapy, associated with air stacking, intermittent positive pressure breathing or mechanical in-exsufflation may be proposed. Care for swallowing disorders, nutritional counseling (cachexia, obesity), vaccinations and therapeutic education are integral elements of patient-centered management aiming to prevent the negative impact of infection and to manage respiratory failure of chronic neuromuscular disease. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  15. Monitoring pulmonary vascular permeability using radiolabeled transferrin

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Basran, G.S.; Hardy, J.G.

    1988-07-01

    A simple, noninvasive technique for monitoring pulmonary vascular permeability in patients in critical care units is discussed. High vascular permeability is observed in patients with clinically defined adult respiratory distress syndrome (ARDS) but not in patients with hydrostatic pulmonary edema or in patients with minor pulmonary insults who are considered to be at risk of developing ARDS. The technique has been used in the field of therapeutics and pharmacology to test the effects of the putative antipermeability agents methylprednisolone and terbutaline sulfate. There appears to be a good correlation between the acute inhibitory effect of either drug on transferrin exudationmore » and patient prognosis. Thus, a byproduct of such drug studies may be an index of survival in patients with established ARDS.« less

  16. Non-invasive ventilation with intelligent volume-assured pressure support versus pressure-controlled ventilation: effects on the respiratory event rate and sleep quality in COPD with chronic hypercapnia.

    PubMed

    Nilius, Georg; Katamadze, Nato; Domanski, Ulrike; Schroeder, Maik; Franke, Karl-Josef

    2017-01-01

    COPD patients who develop chronic hypercapnic respiratory failure have a poor prognosis. Treatment of choice, especially the best form of ventilation, is not well known. This study compared the effects of pressure-controlled (spontaneous timed [ST]) non-invasive ventilation (NIV) and NIV with intelligent volume-assured pressure support (IVAPS) in chronic hypercapnic COPD patients regarding the effects on alveolar ventilation, adverse patient/ventilator interactions and sleep quality. This prospective, single-center, crossover study randomized patients to one night of NIV using ST then one night with the IVAPS function activated, or vice versa. Patients were monitored using polysomnography (PSG) and transcutaneous carbon dioxide pressure (PtcCO 2 ) measurement. Patients rated their subjective experience (total score, 0-45; lower scores indicate better acceptability). Fourteen patients were included (4 females, age 59.4±8.9 years). The total number of respiratory events was low, and similar under pressure-controlled (5.4±6.7) and IVAPS (8.3±10.2) conditions ( P =0.064). There were also no clinically relevant differences in PtcCO 2 between pressure-controlled and IVAPS NIV (52.9±6.2 versus 49.1±6.4 mmHg). Respiratory rate was lower under IVAPS overall; between-group differences reached statistical significance during wakefulness and non-rapid eye movement sleep. Ventilation pressures were 2.6 cmH 2 O higher under IVAPS versus pressure-controlled ventilation, resulting in a 20.1 mL increase in breathing volume. Sleep efficiency was slightly higher under pressure-controlled ventilation versus IVAPS. Respiratory arousals were uncommon (24.4/h [pressure-controlled] versus 25.4/h [IVAPS]). Overall patient assessment scores were similar, although there was a trend toward less discomfort during IVAPS. Our results show that IVAPS NIV allows application of higher nocturnal ventilation pressures versus ST without affecting sleep quality or inducing ventilation- associated events.

  17. Neonatal non-invasive respiratory support: synchronised NIPPV, non-synchronised NIPPV or bi-level CPAP: what is the evidence in 2013?

    PubMed

    Roberts, C T; Davis, P G; Owen, L S

    2013-01-01

    Nasal continuous positive airway pressure (NCPAP) has proven to be an effective mode of non-invasive respiratory support in preterm infants; however, many infants still require endotracheal ventilation, placing them at an increased risk of morbidities such as bronchopulmonary dysplasia. Several other modes of non-invasive respiratory support beyond NCPAP, including synchronised and non-synchronised nasal intermittent positive pressure ventilation (SNIPPV and nsNIPPV) and bi-level positive airway pressure (BiPAP) are now also available. These techniques require different approaches, and the exact mechanisms by which they act remain unclear. SNIPPV has been shown to reduce the rate of reintubation in comparison to NCPAP when used as post-extubation support, but the evidence for nsNIPPV and BiPAP in this context is less convincing. There is some evidence that NIPPV (whether synchronised or non-synchronised) used as primary respiratory support is beneficial, but the variation in study methodology makes this hard to translate confidently into clinical practice. There is currently no evidence to suggest a reduction in mortality or important morbidities such as bronchopulmonary dysplasia, with NIPPV or BiPAP in comparison to NCPAP, and there is a lack of appropriately designed studies in this area. This review discusses the different approaches and proposed mechanisms of action of SNIPPV, nsNIPPV and BiPAP, the challenges of applying the available evidence for these distinct modalities of non-invasive respiratory support to clinical practice, and possible areas of future research. © 2013 S. Karger AG, Basel.

  18. Inferring cardiac phase response curve in vivo

    NASA Astrophysics Data System (ADS)

    Pikovsky, Arkady; Kralemann, Bjoern; Fruehwirth, Matthias; Rosenblum, Michael; Kenner, Thomas; Schaefer, Jochen; Moser, Maximilian

    2014-03-01

    Characterizing properties of biological oscillators with phase response cirves (PRC) is one of main theoretical tools in neuroscience, cardio-respiratory physiology, and chronobiology. We present a technique that allows the extraction of the PRC from a non-invasive observation of a system consisting of two interacting oscillators, in this case heartbeat and respiration, in its natural environment and under free-running conditions. We use this method to obtain the phase coupling functions describing cardio-respiratory interactions and the phase response curve of 17 healthy humans. We show at which phase the cardiac beat is susceptible to respiratory drive and extract the respiratory-related component of heart rate variability. This non-invasive method of bivariate data analysis for the determination of phase response curves of coupled oscillators may find application in other biological and physical systems.

  19. "Cut-and-paste" manufacture of multiparametric epidermal electronic systems

    NASA Astrophysics Data System (ADS)

    Lu, Nanshu; Yang, Shixuan; Wang, Pulin

    2016-05-01

    Epidermal electronics is a class of noninvasive and unobstructive skin-mounted, tattoo-like sensors and electronics capable of vital sign monitoring and establishing human-machine interface. The high cost of manpower, materials, vacuum equipment, and photolithographic facilities associated with its manufacture greatly hinders the widespread use of disposable epidermal electronics. Here we report a cost and time effective, completely dry, benchtop "cut-and-paste" method for the freeform and portable manufacture of multiparametric epidermal sensor systems (ESS) within minutes. This versatile method works for all types of thin metal and polymeric sheets and is compatible with any tattoo adhesives or medical tapes. The resulting ESS are multimaterial and multifunctional and have been demonstrated to noninvasively but accurately measure electrophysiological signals, skin temperature, skin hydration, as well as respiratory rate. In addition, planar stretchable coils exploiting double-stranded serpentine design have been successfully applied as wireless, passive epidermal strain sensors.

  20. Non-Invasive Mechanical Ventilation in Critically Ill Trauma Patients: A Systematic Review

    PubMed Central

    Yıldırım, Fatma; Ferrari, Giovanni; Antonelli, Andrea; Delis, Pablo Bayoumy; Gündüz, Murat; Karcz, Marcin; Papadakos, Peter; Cosentini, Roberto; Dikmen, Yalım; Esquinas, Antonio M.

    2018-01-01

    There is limited literature on non-invasive mechanical ventilation (NIMV) in patients with polytrauma-related acute respiratory failure (ARF). Despite an increasing worldwide application, there is still scarce evidence of significant NIMV benefits in this specific setting, and no clear recommendations are provided. We performed a systematic review, and a search of clinical databases including MEDLINE and EMBASE was conducted from the beginning of 1990 until today. Although the benefits in reducing the intubation rate, morbidity and mortality are unclear, NIMV may be useful and does not appear to be associated with harm when applied in properly selected patients with moderate ARF at an earlier stage of injury by experienced teams and in appropriate settings under strict monitoring. In the presence of these criteria, NIMV is worth attempting, but only if endotracheal intubation is promptly available because non-responders to NIMV are burdened by an increased mortality when intubation is delayed. PMID:29744242

  1. Non-invasive Imaging of Sendai Virus Infection in Pharmacologically Immunocompromised Mice: NK and T Cells, but not Neutrophils, Promote Viral Clearance after Therapy with Cyclophosphamide and Dexamethasone

    PubMed Central

    Mostafa, Heba H.; Vogel, Peter; Srinivasan, Ashok; Russell, Charles J.

    2016-01-01

    In immunocompromised patients, parainfluenza virus (PIV) infections have an increased potential to spread to the lower respiratory tract (LRT), resulting in increased morbidity and mortality. Understanding the immunologic defects that facilitate viral spread to the LRT will help in developing better management protocols. In this study, we immunosuppressed mice with dexamethasone and/or cyclophosphamide then monitored the spread of viral infection into the LRT by using a noninvasive bioluminescence imaging system and a reporter Sendai virus (murine PIV type 1). Our results show that immunosuppression led to delayed viral clearance and increased viral loads in the lungs. After cessation of cyclophosphamide treatment, viral clearance occurred before the generation of Sendai-specific antibody responses and coincided with rebounds in neutrophils, T lymphocytes, and natural killer (NK) cells. Neutrophil suppression using anti-Ly6G antibody had no effect on infection clearance, NK-cell suppression using anti-NK antibody delayed clearance, and T-cell suppression using anti-CD3 antibody resulted in no clearance (chronic infection). Therapeutic use of hematopoietic growth factors G-CSF and GM-CSF had no effect on clearance of infection. In contrast, treatment with Sendai virus—specific polysera or a monoclonal antibody limited viral spread into the lungs and accelerated clearance. Overall, noninvasive bioluminescence was shown to be a useful tool to study respiratory viral progression, revealing roles for NK and T cells, but not neutrophils, in Sendai virus clearance after treatment with dexamethasone and cyclophosphamide. Virus-specific antibodies appear to have therapeutic potential. PMID:27589232

  2. The NAPRESSIM trial: the use of low-dose, prophylactic naloxone infusion to prevent respiratory depression with intrathecally administered morphine in elective hepatobiliary surgery: a study protocol and statistical analysis plan for a randomised controlled trial.

    PubMed

    Cosgrave, David; Galligan, Marie; Soukhin, Era; McMullan, Victoria; McGuinness, Siobhan; Puttappa, Anand; Conlon, Niamh; Boylan, John; Hussain, Rabia; Doran, Peter; Nichol, Alistair

    2017-12-29

    Intrathecally administered morphine is effective as part of a postoperative analgesia regimen following major hepatopancreaticobiliary surgery. However, the potential for postoperative respiratory depression at the doses required for effective analgesia currently limits its clinical use. The use of a low-dose, prophylactic naloxone infusion following intrathecally administered morphine may significantly reduce postoperative respiratory depression. The NAPRESSIM trial aims to answer this question. 'The use of low-dose, prophylactic naloxone infusion to prevent respiratory depression with intrathecally administered morphine' trial is an investigator-led, single-centre, randomised, double-blind, placebo-controlled, double-arm comparator study. The trial will recruit 96 patients aged > 18 years, undergoing major open hepatopancreaticobiliary resections, who are receiving intrathecally administered morphine as part of a standard anaesthetic regimen. It aims to investigate whether the prophylactic administration of naloxone via intravenous infusion compared to placebo will reduce the proportion of episodes of respiratory depression in this cohort of patients. Trial patients will receive an infusion of naloxone or placebo, commenced within 1 h of postoperative extubation continued until the first postoperative morning. The primary outcome is the rate of respiratory depression in the intervention group as compared to the placebo group. Secondary outcomes include pain scores, rates of nausea and vomiting, pruritus, sedation scores and adverse outcomes. We will also employ a novel, non-invasive, respiratory minute volume monitor (ExSpiron 1Xi, Respiratory Motion, Inc., 411 Waverley Oaks Road, Building 1, Suite 150, Waltham, MA, USA) to assess the monitor's accuracy for detecting respiratory depression. The trial aims to provide a clear management plan to prevent respiratory depression after the intrathecal administration of morphine, and thereby improve patient safety. ClinicalTrials.gov, ID: NCT02885948 . Registered retrospectively on 4 July 2016. Protocol Version 2.0, 3 April 2017. Protocol identification (code or reference number): UCDCRC/15/006 EudraCT registration number: 2015-003504-22. Registered on 5 August 2015.

  3. Accuracy of continuous noninvasive arterial pressure monitoring in living-liver donors during transplantation.

    PubMed

    Araz, Coskun; Zeyneloglu, Pinar; Pirat, Arash; Veziroglu, Nukhet; Camkiran Firat, Aynur; Arslan, Gulnaz

    2015-04-01

    Hemodynamic monitoring is vital during liver transplant surgeries because distinct hemodynamic changes are expected. The continuous noninvasive arterial pressure (CNAP) monitor is a noninvasive device for continuous arterial pressure measurement by a tonometric method. This study compared continuous noninvasive arterial pressure monitoring with invasive direct arterial pressure monitoring in living-liver donors during transplant. There were 40 patients analyzed while undergoing hepatic lobectomy for liver transplant. Invasive pressure monitoring was established at the radial artery and continuous noninvasive arterial pressure monitoring using a finger sensor was recorded simultaneously from the contralateral arm. Systolic, diastolic, and mean arterial pressures from the 2 methods were compared. Correlation between the 2 methods was calculated. A total of 5433 simultaneous measurements were obtained. For systolic arterial blood pressure, 55% continuous noninvasive arterial pressure measurements were within 10% direct arterial measurement; the correlation was 0.479, continuous noninvasive arterial pressure bias was -0.3 mm Hg, and limits of agreement were 32.0 mm Hg. For diastolic arterial blood pressure, 50% continuous noninvasive arterial pressure measurements were within 10% direct arterial measurement; the correlation was 0.630, continuous noninvasive arterial pressure bias was -0.4 mm Hg, and limits of agreement were 21.1 mm Hg. For mean arterial blood pressure, 60% continuous noninvasive arterial pressure measurements were within 10% direct arterial measurement; the correlation was 0.692, continuous noninvasive arterial pressure bias was +0.4 mm Hg, and limits of agreement were 20.8 mm Hg. The 2 monitoring techniques did not show acceptable agreement. Our results suggest that continuous noninvasive arterial pressure monitoring is not equivalent to invasive arterial pressure monitoring in donors during living-donor liver transplant.

  4. Application of non-invasive mechanical ventilation in an asthmatic pregnant woman in respiratory failure: a case report

    PubMed Central

    Caner, Hanife; Eryuksel, Emel; Kosar, Filiz

    2013-01-01

    The use of non-invasive mechanical ventilation (NIV) during an asthma attack is controversial. We report a case of a 28-year-old female patient in her 16th week of pregnancy with community-acquired pneumonia who presented during an asthma attack, which led to hypoxic respiratory failure. She was successfully treated using NIV. This case is worth discussing as it includes two clinical conditions in which NIV is often considered contraindicated. PMID:23372957

  5. Using Supervised Machine Learning to Classify Real Alerts and Artifact in Online Multi-signal Vital Sign Monitoring Data

    PubMed Central

    Chen, Lujie; Dubrawski, Artur; Wang, Donghan; Fiterau, Madalina; Guillame-Bert, Mathieu; Bose, Eliezer; Kaynar, Ata M.; Wallace, David J.; Guttendorf, Jane; Clermont, Gilles; Pinsky, Michael R.; Hravnak, Marilyn

    2015-01-01

    OBJECTIVE Use machine-learning (ML) algorithms to classify alerts as real or artifacts in online noninvasive vital sign (VS) data streams to reduce alarm fatigue and missed true instability. METHODS Using a 24-bed trauma step-down unit’s non-invasive VS monitoring data (heart rate [HR], respiratory rate [RR], peripheral oximetry [SpO2]) recorded at 1/20Hz, and noninvasive oscillometric blood pressure [BP] less frequently, we partitioned data into training/validation (294 admissions; 22,980 monitoring hours) and test sets (2,057 admissions; 156,177 monitoring hours). Alerts were VS deviations beyond stability thresholds. A four-member expert committee annotated a subset of alerts (576 in training/validation set, 397 in test set) as real or artifact selected by active learning, upon which we trained ML algorithms. The best model was evaluated on alerts in the test set to enact online alert classification as signals evolve over time. MAIN RESULTS The Random Forest model discriminated between real and artifact as the alerts evolved online in the test set with area under the curve (AUC) performance of 0.79 (95% CI 0.67-0.93) for SpO2 at the instant the VS first crossed threshold and increased to 0.87 (95% CI 0.71-0.95) at 3 minutes into the alerting period. BP AUC started at 0.77 (95%CI 0.64-0.95) and increased to 0.87 (95% CI 0.71-0.98), while RR AUC started at 0.85 (95%CI 0.77-0.95) and increased to 0.97 (95% CI 0.94–1.00). HR alerts were too few for model development. CONCLUSIONS ML models can discern clinically relevant SpO2, BP and RR alerts from artifacts in an online monitoring dataset (AUC>0.87). PMID:26992068

  6. Laryngeal closure impedes non-invasive ventilation at birth.

    PubMed

    Crawshaw, Jessica R; Kitchen, Marcus J; Binder-Heschl, Corinna; Thio, Marta; Wallace, Megan J; Kerr, Lauren T; Roehr, Charles C; Lee, Katie L; Buckley, Genevieve A; Davis, Peter G; Flemmer, Andreas; Te Pas, Arjan B; Hooper, Stuart B

    2018-03-01

    Non-invasive ventilation is sometimes unable to provide the respiratory needs of very premature infants in the delivery room. While airway obstruction is thought to be the main problem, the site of obstruction is unknown. We investigated whether closure of the larynx and epiglottis is a major site of airway obstruction. We used phase contrast X-ray imaging to visualise laryngeal function in spontaneously breathing premature rabbits immediately after birth and at approximately 1 hour after birth. Non-invasive respiratory support was applied via a facemask and images were analysed to determine the percentage of the time the glottis and the epiglottis were open. Immediately after birth, the larynx is predominantly closed, only opening briefly during a breath, making non-invasive intermittent positive pressure ventilation (iPPV) ineffective, whereas after lung aeration, the larynx is predominantly open allowing non-invasive iPPV to ventilate the lung. The larynx and epiglottis were predominantly closed (open 25.5%±1.1% and 17.1%±1.6% of the time, respectively) in pups with unaerated lungs and unstable breathing patterns immediately after birth. In contrast, the larynx and the epiglottis were mostly open (90.5%±1.9% and 72.3%±2.3% of the time, respectively) in pups with aerated lungs and stable breathing patterns irrespective of time after birth. Laryngeal closure impedes non-invasive iPPV at birth and may reduce the effectiveness of non-invasive respiratory support in premature infants immediately after birth. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  7. Optimal wavelength selection for noncontact reflection photoplethysmography

    NASA Astrophysics Data System (ADS)

    Corral Martinez, Luis F.; Paez, Gonzalo; Strojnik, Marija

    2011-08-01

    In this work, we obtain backscattered signals from human forehead for wavelengths from 380 to 980 nm. The results reveal bands with strong pulsatile signals that carry useful information. We describe those bands as the most suitable wavelengths in the visible and NIR regions from which heart and respiratory rate parameters can be derived using long distance non-contact reflection photoplethysmography analysis. The latter results show the feasibility of a novel technique for remotely detection of vital signs in humans. This technique, which may include morphological analysis or maps of tissue oxygenation, is a further step to real non-invasive remote monitoring of patients.

  8. Perspectives on advance care planning among patients recently requiring non-invasive ventilation for acute respiratory failure: A qualitative study using thematic analysis.

    PubMed

    Smith, Tracy A; Disler, Rebecca T; Jenkins, Christine R; Ingham, Jane M; Davidson, Patricia M

    2017-06-01

    Patients requiring non-invasive ventilation for acute-on-chronic respiratory failure due to chronic obstructive pulmonary disease or heart failure exacerbations may have a poor prognosis underscoring the importance of advance care planning. We aimed to describe attitudes to, and experiences of, discussing the future among patients recently treated with non-invasive ventilation. Qualitative research using thematic analysis. Tertiary teaching hospital. Patients with acute hypercapnic respiratory failure requiring non-invasive ventilation. Individuals recently treated with non-invasive ventilation describe feeling the future is beyond their control and instead controlled by their illness. Participants often recognised their poor prognosis but avoided discussing some difficult topics. The majority preferred not to undergo cardiopulmonary resuscitation but most had not discussed this with healthcare professionals. When participants voiced concerns about their future health to family members, they were met with polarised responses. Some encountered willingness for further discussion, while others met deflection, deterring further conversation. An overarching narrative of 'Looking through my illness to an uncertain but concerning future' unites these themes. This study suggests opportunities and barriers for advance care planning in individuals with chronic disease. Patients' understanding of their prognosis and their attitudes to cardiopulmonary resuscitation suggests an opportunity for advance care planning. Structuring discussions around patients' preferences for care during future exacerbations may foster a sense of control over the future despite illness. The diversity of familial responses to patients' concerns about their future health has implications for advance care planning. These findings have the potential to improve care for patients with respiratory failure and suggest an important ongoing research agenda.

  9. Non-Invasive Acoustic-Based Monitoring of Heavy Water and Uranium Process Solutions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pantea, Cristian; Sinha, Dipen N.; Lakis, Rollin Evan

    This presentation includes slides on Project Goals; Heavy Water Production Monitoring: A New Challenge for the IAEA; Noninvasive Measurements in SFAI Cell; Large Scatter in Literature Values; Large Scatter in Literature Values; Highest Precision Sound Speed Data Available: New Standard in H/D; ~400 pts of data; Noninvasive Measurements in SFAI Cell; New funding from NA241 SGTech; Uranium Solution Monitoring: Inspired by IAEA Challenge in Kazakhstan; Non-Invasive Acoustic-Based Monitoring of Uranium in Solutions; Non-Invasive Acoustic-Based Monitoring of Uranium in Solutions; and finally a summary.

  10. [Pediatric home ventilation--practical approach].

    PubMed

    Rath-Wacenovsky, Regina

    2015-09-01

    Out-of-hospital ventilation represents only a marginal area of paediatric therapeutic concepts. In Austria, the proportion of children to be supplied with invasive and non-invasive ventilation increases significantly, together with the challenges of caring for their long-term demands. Neuromuscular diseases accounted for almost the sole indication group. Premature and newborn infants with persistent respiratory failures are an increasing group, needing more extensive care due to additional comorbidities. Children with congenital disorder have often been tracheotomised in order to secure their airway, and non-invasive ventilation as a bridge- or long-term therapy gains in importance more and more. Usually, infants with primary or secondary CNS disorders suffer from respiratory complications and eventually from chronic respiratory insufficiencies during adolescence or young adulthood. Here, invasive or non-invasive ventilation can contribute both to a significant stabilisation of health status and also quality of life. Spirit of research, experience, appropriate support structures, and appropriate networking constitute the most relevant quality- and success criteria for home care.

  11. Role of non-invasive ventilation (NIV) in the perioperative period.

    PubMed

    Jaber, Samir; Michelet, Pierre; Chanques, Gerald

    2010-06-01

    Anaesthesia, postoperative pain and surgery (more so if the site of the surgery approaches the diaphragm) will induce respiratory modifications: hypoxaemia, pulmonary volume decrease and atelectasis associated to a restrictive syndrome and a diaphragm dysfunction. These modifications of the respiratory function occur early after surgery and may induce acute respiratory failure (ARF). Maintenance of adequate oxygenation in the postoperative period is of major importance, especially when pulmonary complications such as ARF occur. Non-invasive ventilation (NIV) refers to techniques allowing respiratory support without the need of endotracheal intubation. Two types of NIV are commonly used: noninvasive continuous positive airway pressure (CPAP) and noninvasive positive pressure ventilation (NPPV) which delivers two levels of positive pressure (pressure support ventilation + positive end-expiratory pressure). NIV may be an important tool to prevent (prophylactic treatment) or to treat ARF avoiding intubation (curative treatment). The aims of NIV are: (1) to partially compensate for the affected respiratory function by reducing the work of breathing, (2) to improve alveolar recruitment with better gas exchange (oxygenation and ventilation) and (3) to reduce left ventricular after load increasing cardiac output and improving haemodynamics. Evidence suggests that NIV, as a prophylactic or curative treatment, has been proven to be an effective strategy to reduce intubation rates, nosocomial infections, intensive care unit and hospital lengths of stay, morbidity and mortality in postoperative patients. However, before initiating NIV, any surgical complication must be treated. The aims of this article are (1) to describe the rationale behind the application of NIV, (2) to report indications (including induction of anaesthesia) and contraindications and (3) to offer some algorithms for safe usage of NIV in high-risk surgery patients.

  12. Monitoring the state of the human airways by analysis of respiratory sound

    NASA Technical Reports Server (NTRS)

    Hardin, J. C.; Patterson, J. L., Jr.

    1978-01-01

    A mechanism whereby sound is generated by the motion of vortices in the human lung is described. This mechanism is believed to be responsible for most of the sound which is generated both on inspiration and expiration in normal lungs. Mathematical expressions for the frequencies of sound generated, which depend only upon the axial flow velocity and diameters of the bronchi, are derived. This theory allows the location within the bronchial tree from which particular sounds emanate to be determined. Redistribution of pulmonary blood volume following transition from earth gravity to the weightless state probably alters the caliber of certain airways and doubtless alters sound transmission properties of the lung. We believe that these changes can be monitored effectively and non-invasively by spectral analysis of pulmonary sound.

  13. Monitoring the state of the human airways by analysis of respiratory sound

    NASA Technical Reports Server (NTRS)

    Hardin, J. C.; Patterson, J. L. Jr

    1979-01-01

    A mechanism whereby sound is generated by the motion of vortices in the human lung is described. This mechanism is believed to be responsible for most of the sound which is generated both on inspiration and expiration in normal lungs. Mathematical expressions for the frequencies of sound generated, which depend only upon the axial flow velocity and diameters of the bronchi, are derived. This theory allows the location within the bronchial tree from which particular sounds emanate to be determined. Redistribution of pulmonary blood volume following transition from Earth gravity to the weightless state probably alters the caliber of certain airways and doubtless alters sound transmission properties of the lung. We believe that these changes can be monitored effectively and non-invasively by spectral analysis of pulmonary sound.

  14. The obese patient undergoing nonbariatric surgery.

    PubMed

    Bluth, Thomas; Pelosi, Paolo; de Abreu, Marcelo Gama

    2016-06-01

    This article provides the reader with recent findings on the pathophysiology of comorbidities in the obese, as well as evidence-based treatment options to deal with perioperative respiratory challenges. Our understanding of obesity-associated asthma, obstructive sleep apnea, and obesity hypoventilation syndrome is still expanding. Routine screening for obstructive sleep apnea using the STOP-Bang score might identify high-risk patients that benefit from perioperative continuous positive airway pressure and close postoperative monitoring. Measures to most effectively support respiratory function during induction of and emergence from anesthesia include optimal patient positioning and use of noninvasive positive pressure ventilation. Appropriate mechanical ventilation settings are under investigation, so that only the use of protective low tidal volumes could be currently recommended. A multimodal approach consisting of adjuvants, as well as regional anesthesia/analgesia techniques reduces the need for systemic opioids and related respiratory complications. Anesthesia of obese patients for nonbariatric surgical procedures requires knowledge of typical comorbidities and their respective treatment options. Apart from cardiovascular diseases associated with the metabolic syndrome, awareness of any pulmonary dysfunction is of paramount. A multimodal analgesia approach may be useful to reduce postoperative pulmonary complications.

  15. Real alerts and artifact classification in archived multi-signal vital sign monitoring data: implications for mining big data.

    PubMed

    Hravnak, Marilyn; Chen, Lujie; Dubrawski, Artur; Bose, Eliezer; Clermont, Gilles; Pinsky, Michael R

    2016-12-01

    Huge hospital information system databases can be mined for knowledge discovery and decision support, but artifact in stored non-invasive vital sign (VS) high-frequency data streams limits its use. We used machine-learning (ML) algorithms trained on expert-labeled VS data streams to automatically classify VS alerts as real or artifact, thereby "cleaning" such data for future modeling. 634 admissions to a step-down unit had recorded continuous noninvasive VS monitoring data [heart rate (HR), respiratory rate (RR), peripheral arterial oxygen saturation (SpO 2 ) at 1/20 Hz, and noninvasive oscillometric blood pressure (BP)]. Time data were across stability thresholds defined VS event epochs. Data were divided Block 1 as the ML training/cross-validation set and Block 2 the test set. Expert clinicians annotated Block 1 events as perceived real or artifact. After feature extraction, ML algorithms were trained to create and validate models automatically classifying events as real or artifact. The models were then tested on Block 2. Block 1 yielded 812 VS events, with 214 (26 %) judged by experts as artifact (RR 43 %, SpO 2 40 %, BP 15 %, HR 2 %). ML algorithms applied to the Block 1 training/cross-validation set (tenfold cross-validation) gave area under the curve (AUC) scores of 0.97 RR, 0.91 BP and 0.76 SpO 2 . Performance when applied to Block 2 test data was AUC 0.94 RR, 0.84 BP and 0.72 SpO 2 . ML-defined algorithms applied to archived multi-signal continuous VS monitoring data allowed accurate automated classification of VS alerts as real or artifact, and could support data mining for future model building.

  16. Real Alerts and Artifact Classification in Archived Multi-signal Vital Sign Monitoring Data—Implications for Mining Big Data — Implications for Mining Big Data

    PubMed Central

    Hravnak, Marilyn; Chen, Lujie; Dubrawski, Artur; Bose, Eliezer; Clermont, Gilles; Pinsky, Michael R.

    2015-01-01

    PURPOSE Huge hospital information system databases can be mined for knowledge discovery and decision support, but artifact in stored non-invasive vital sign (VS) high-frequency data streams limits its use. We used machine-learning (ML) algorithms trained on expert-labeled VS data streams to automatically classify VS alerts as real or artifact, thereby “cleaning” such data for future modeling. METHODS 634 admissions to a step-down unit had recorded continuous noninvasive VS monitoring data (heart rate [HR], respiratory rate [RR], peripheral arterial oxygen saturation [SpO2] at 1/20Hz., and noninvasive oscillometric blood pressure [BP]) Time data were across stability thresholds defined VS event epochs. Data were divided Block 1 as the ML training/cross-validation set and Block 2 the test set. Expert clinicians annotated Block 1 events as perceived real or artifact. After feature extraction, ML algorithms were trained to create and validate models automatically classifying events as real or artifact. The models were then tested on Block 2. RESULTS Block 1 yielded 812 VS events, with 214 (26%) judged by experts as artifact (RR 43%, SpO2 40%, BP 15%, HR 2%). ML algorithms applied to the Block 1 training/cross-validation set (10-fold cross-validation) gave area under the curve (AUC) scores of 0.97 RR, 0.91 BP and 0.76 SpO2. Performance when applied to Block 2 test data was AUC 0.94 RR, 0.84 BP and 0.72 SpO2). CONCLUSIONS ML-defined algorithms applied to archived multi-signal continuous VS monitoring data allowed accurate automated classification of VS alerts as real or artifact, and could support data mining for future model building. PMID:26438655

  17. Striving for habitual well-being in noninvasive ventilation: a grounded theory study of chronic obstructive pulmonary disease patients with acute respiratory failure.

    PubMed

    Sørensen, Dorthe; Frederiksen, Kirsten; Groefte, Thorbjoern; Lomborg, Kirsten

    2014-06-01

    To present a theoretical account of the pattern of behaviour in patients with acute respiratory failure due to chronic obstructive pulmonary disease while undergoing noninvasive ventilation in a hospital setting. Strong evidence supports a positive effect of noninvasive ventilation, but successful treatment remains a challenge. Little attention has been given to patient intolerance to noninvasive ventilation as a cause of treatment failure. A better understanding of the patients' patterns of behaviour during noninvasive ventilation may improve treatment success. A constant comparative classic grounded theory study was performed. Data collection consisted of participant observation during the treatment of 21 patients undergoing noninvasive ventilation, followed by interviews with 11 of the patients after treatment completion. Data were collected from December 2009-January 2012. A substantive theory of striving for habitual well-being was developed. The theory included three phases: initiation, transition and determination. Each phase contained a set of subcategories to indicate the dimensions of and variations in the participants' behaviour. The substantive theory revealed that the patients' behaviour was related to their breathlessness, sensation of being restrained by the mask and head gear, and the side effects of noninvasive ventilation. This inter-relationship should be addressed in the use of noninvasive ventilation for the treatment of patients with chronic obstructive pulmonary disease to achieve treatment success. © 2013 John Wiley & Sons Ltd.

  18. Non-invasively estimated ICP pulse amplitude strongly correlates with outcome after TBI.

    PubMed

    Budohoski, Karol P; Schmidt, Bernhard; Smielewski, Peter; Kasprowicz, Magdalena; Plontke, Ronny; Pickard, John D; Klingelhöfer, Jurgen; Czosnyka, Marek

    2012-01-01

    An existing monitoring database of brain signal recordings in patients with head injury has been re-evaluated with regard to the accuracy of estimation of non-invasive ICP (nICP) and its components, with a particular interest in the implications for outcome after head injury. Middle cerebral artery blood flow velocity (FV), ICP and arterial blood pressure (ABP) were recorded. Non-invasive ICP (nICP) was calculated using a mathematical model. Other signals analysed included components of ICP (n" indicates non-invasive): ICP pulse amplitude (Amp, nAmp), amplitude of the respiratory component (Resp, nResp), amplitude of slow vasogenic waves of ICP (Slow, nSlow) and index of compensatory reserve (RAP, nRAP). Mean values of analysed signals were compared against each other and between patients who died and survived. The correlation between ICP and nICP was moderately strong, R = 0.51 (95% prediction interval [PI] 17 mm Hg). The components of nICP and ICP were also moderately correlated with each other: the strongest correlation was observed for Resp vs. nResp (r = 0.66), while weaker for Amp vs. nAmp (r = 0.41). Non-invasive pulse amplitude of ICP showed the strongest association with outcome, with the -difference between those who survived and those who died reaching a significance level of p < 0.000001. When compared between patients who died and who survived mean nAmp showed the greatest difference, suggesting its potential to predict mortality after TBI.

  19. An international survey on noninvasive ventilation use for acute respiratory failure in general non-monitored wards.

    PubMed

    Cabrini, Luca; Esquinas, Antonio; Pasin, Laura; Nardelli, Pasquale; Frati, Elena; Pintaudi, Margherita; Matos, Paulo; Landoni, Giovanni; Zangrillo, Alberto

    2015-04-01

    Use of noninvasive ventilation (NIV) for the treatment of patients with acute respiratory failure (ARF) has greatly increased in the last decades. In contrast, the increasing knowledge of its effectiveness and physician confidence in managing this technique have been accompanied by a declining number of available ICU beds. As a consequence, the application of NIV outside the ICU has been reported as a growing phenomenon. Previously published surveys highlighted a great heterogeneity in NIV use, clinical indications, settings, and efficacy. Moreover, they revealed a marked heterogeneity with regard to staff training and technical and organizational aspects. We performed the first worldwide web-based survey focused on NIV use in general wards for ARF. A questionnaire to obtain data regarding hospital and ICU characteristics, settings and modalities of NIV application and monitoring, estimated outcomes, technical and organizational aspects, and observed complications was developed. The multiple-choice anonymous questionnaire to be filled out online was distributed worldwide by mail, LinkedIn, and Facebook professional groups. One-hundred fifty-seven questionnaires were filled out and analyzed. Respondents were from 51 countries from all 5 continents. NIV application in general wards was reported by 66% of respondents. Treatments were reported as increasing in 57% of cases. Limited training and human resources were the most common reasons for not using NIV in general wards. Overall, most respondents perceived that NIV avoids tracheal intubation in most cases; worsening of ARF, intolerance, and inability to manage secretions were the most commonly reported causes of NIV failure. Use of NIV in general wards was reported as effective, common, and gradually increasing. Improvement in staff training and introduction of protocols could help to make this technique safer and more common when applied in general wards setting. Copyright © 2015 by Daedalus Enterprises.

  20. Estimating phonation threshold pressure.

    PubMed

    Fisher, K V; Swank, P R

    1997-10-01

    Phonation threshold pressure (PTP) is the minimum subglottal pressure required to initiate vocal fold oscillation. Although potentially useful clinically, PTP is difficult to estimate noninvasively because of limitations to vocal motor control near the threshold of soft phonation. Previous investigators observed, for example, that trained subjects were unable to produce flat, consistent oral pressure peaks during/pae/syllable strings when they attempted to phonate as softly as possible (Verdolini-Marston, Titze, & Druker, 1990). The present study aimed to determine if nasal airflow or vowel context affected phonation threshold pressure as estimated from oral pressure (Smitheran & Hixon, 1981) in 5 untrained female speakers with normal velopharyngeal and voice function. Nasal airflow during /p/occlusion was observed for 3 of 5 participants when they attempted to phonate near threshold pressure. When the nose was occluded, nasal airflow was reduced or eliminated during /p/;however, individuals then evidenced compensatory changes in glottal adduction and/or respiratory effort that may be expected to alter PTP estimates. Results demonstrate the importance of monitoring nasal flow (or the flow zero point in undivided masks) when obtaining PTP measurements noninvasively. Results also highlight the need to pursue improved methods for noninvasive estimation of PTP.

  1. Measures of Autonomic Nervous System Regulation

    DTIC Science & Technology

    2011-04-01

    and most often used measures of ANS activation encompass non-invasive tools, which measure cardiac, skin conductance, respiratory , and vascular...regulation, osmotic balance, metabolism, digestion, excretion, and cardiac and respiratory activity. The ANS consists of the sympathetic and...modulate heart rate, as a function of the respiratory cycles. Generally, these two systems should be seen as permanently modulating vital functions to

  2. Measures of Autonomic Nervous System

    DTIC Science & Technology

    2011-04-01

    activation encompass non-invasive tools, which measure cardiac, skin conductance, respiratory , and vascular activity. Choice of tools is dependent upon...digestion, excretion, and cardiac and respiratory activity. The ANS consists of the sympathetic and parasympathetic divisions and acts through a... respiratory cycles. Generally, these two systems should be seen as permanently modulating vital functions to achieve homeostasis. Since both systems are

  3. Non-invasive mechanical ventilation with spinal anesthesia for cesarean delivery.

    PubMed

    Erdogan, G; Okyay, D Z; Yurtlu, S; Hanci, V; Ayoglu, H; Koksal, B; Turan, I O

    2010-10-01

    We present the successful use of perioperative non-invasive mechanical ventilation in a morbidly obese pregnant woman with bronchial asthma, severe preeclampsia and pulmonary edema undergoing an emergency cesarean delivery with spinal anesthesia. The combination of non-invasive mechanical ventilation with neuraxial anesthesia may be of value in selected parturients with acute or chronic respiratory insufficiency requiring surgery. Copyright © 2010 Elsevier Ltd. All rights reserved.

  4. Real-time detection, classification, and quantification of apneic episodes using miniature surface motion sensors in rats.

    PubMed

    Waisman, Dan; Lev-Tov, Lior; Levy, Carmit; Faingersh, Anna; Colman Klotzman, Ifat; Bibi, Haim; Rotschild, Avi; Landesberg, Amir

    2015-07-01

    Real-time detection and classification of apneic episodes remain significant challenges. This study explores the applicability of a novel method of monitoring the respiratory effort and dynamics for rapid detection and classification of apneic episodes. Obstructive apnea (OA) and hypopnea/central apnea (CA) were induced in nine tracheostomized rats, by short-lived airway obstruction and administration of succinylcholine, respectively. Esophageal pressure (EP), EtCO2, arterial O2 saturation (SpO2), heart rate, and blood pressure were monitored. Respiratory dynamics were monitored utilizing three miniature motion sensors placed on the chest and epigastrium. Three indices were derived from these sensors: amplitude of the tidal chest wall displacement (TDi), breath time length (BTL), that included inspiration and rapid expiration phases, and amplitude time integral (ATI), the integral of breath amplitude over time. OA induced a progressive 6.42 ± 3.48-fold increase in EP from baseline, which paralleled a 3.04 ± 1.19-fold increase in TDi (P < 0.0012), a 1.39 ± 0.22-fold increase in BTL (P < 0.0002), and a 3.32 ± 1.40-fold rise in the ATI (P < 0.024). During central hypopneic/apneic episodes, each sensor revealed a gradual decrease in TDi, which culminated in absence of breathing attempts. Noninvasive monitoring of chest wall dynamics enables detection and classification of central and obstructive apneic episodes, which tightly correlates with the EP.

  5. [Robotic prostatectomy: The anesthetist's view for robotic urological surgeries, a prospective study].

    PubMed

    Oksar, Menekse; Akbulut, Ziya; Ocal, Hakan; Balbay, Mevlana Derya; Kanbak, Orhan

    2014-01-01

    Although many features of robotic prostatectomy are similar to those of conventional laparoscopic urological procedures (such as laparoscopic prostatectomy), the procedure is associated with some drawbacks, which include limited intravenous access, relatively long operating time, deep Trendelenburg position, and high intra-abdominal pressure. The primary aim was to describe respiratory and hemodynamic challenges and the complications related to high intra-abdominal pressure and the deep Trendelenburg position in robotic prostatectomy patients. The secondary aim was to reveal safe discharge criteria from the operating room. Fifty-three patients who underwent robotic prostatectomy between December 2009 and January 2011 were prospectively enrolled. Main outcome measures were non-invasive monitoring, invasive monitoring and blood gas analysis performed at supine (T0), Trendelenburg (T1), Trendelenburg + pneumoperitoneum (T2), Trendelenburg-before desufflation (T3), Trendelenburg (after desufflation) (T4), and supine (T5) positions. Fifty-three robotic prostatectomy patients were included in the study. The main clinical challenge in our study group was the choice of ventilation strategy to manage respiratory acidosis, which is detected through end-tidal carbon dioxide pressure and blood gas analysis. Furthermore, the mean arterial pressure remained unchanged, the heart rate decreased significantly and required intervention. The central venous pressure values were also above the normal limits. Respiratory acidosis and "upper airway obstruction-like" clinical symptoms were the main challenges associated with robotic prostatectomy procedures during this study. Copyright © 2013 Sociedade Brasileira de Anestesiologia. Publicado por Elsevier Editora Ltda. All rights reserved.

  6. Diode laser spectroscopy for noninvasive monitoring of oxygen in the lungs of newborn infants.

    PubMed

    Svanberg, Emilie Krite; Lundin, Patrik; Larsson, Marcus; Åkeson, Jonas; Svanberg, Katarina; Svanberg, Sune; Andersson-Engels, Stefan; Fellman, Vineta

    2016-04-01

    Newborn infants may have pulmonary disorders with abnormal gas distribution, e.g., respiratory distress syndrome. Pulmonary radiography is the clinical routine for diagnosis. Our aim was to investigate a novel noninvasive optical technique for rapid nonradiographic bedside detection of oxygen gas in the lungs of full-term newborn infants. Laser spectroscopy was used to measure contents of oxygen gas (at 760 nm) and of water vapor (at 937 nm) in the lungs of 29 healthy newborn full-term infants (birth weight 2,900-3,900 g). The skin above the lungs was illuminated using two low-power diode lasers and diffusely emerging light was detected with a photodiode. Of the total 390 lung measurements performed, clear detection of oxygen gas was recorded in 60%, defined by a signal-to-noise ratio of >3. In all the 29 infants, oxygen was detected. Probe and detector positions for optimal pulmonary gas detection were determined. There were no differences in signal quality with respect to gender, body side or body weight. The ability to measure pulmonary oxygen content in healthy full-term neonates with this technique suggests that with further development, the method might be implemented in clinical practice for lung monitoring in neonatal intensive care.

  7. Quantitative versus qualitative cultures of respiratory secretions for clinical outcomes in patients with ventilator-associated pneumonia.

    PubMed

    Berton, Danilo Cortozi; Kalil, Andre C; Cavalcanti, Manuela; Teixeira, Paulo José Zimermann

    2008-10-08

    Ventilator-associated pneumonia (VAP) is a common infectious disease in intensive care units (ICUs). The best diagnostic approach to resolve this condition remains uncertain. To evaluate whether quantitative cultures of respiratory secretions are effective in reducing mortality in immunocompetent patients with VAP, compared with qualitative cultures. We also considered changes in antibiotic use, length of ICU stay and mechanical ventilation. We searched the Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library 2007, issue 4), which contains the Acute Respiratory Infections Group's Specialized Register; MEDLINE (1966 to December 2007); EMBASE (1974 to December 2007); and LILACS (1982 to December 2007). Randomized controlled trials (RCTs) comparing respiratory samples processed quantitatively or qualitatively, obtained by invasive or non-invasive methods from immunocompetent patients with VAP, and which analyzed the impact of these methods on antibiotic use and mortality rates. Two review authors independently reviewed and selected trials from the search results, and assessed studies for suitability, methodology and quality. We analyzed data using Review Manager software. We pooled the included studies to yield the risk ratio (RR) for mortality and antibiotic change with 95% confidence intervals (CI). Of the 3931 references identified from the electronic databases, five RCTs (1367 patients) met the inclusion criteria. Three studies compared invasive methods using quantitative cultures versus non-invasive methods using qualitative cultures, and were used to answer the main objective of this review. The other two studies compared invasive versus non-invasive methods, both using quantitative cultures. All five studies were combined to compare invasive versus non-invasive interventions for diagnosing VAP. The studies that compared quantitative and qualitative cultures (1240 patients) showed no statistically significant differences in mortality rates (RR = 0.91, 95% CI 0.75 to 1.11). The analysis of all five RCTs showed there was no evidence of mortality reduction in the invasive group versus the non-invasive group (RR = 0.93, 95% CI 0.78 to 1.11). There were no significant differences between the interventions with respect to the number of days on mechanical ventilation, length of ICU stay or antibiotic change. There is no evidence that the use of quantitative cultures of respiratory secretions results in reduced mortality, reduced time in ICU and on mechanical ventilation, or higher rates of antibiotic change when compared to qualitative cultures in patients with VAP. Similar results were observed when invasive strategies were compared with non-invasive strategies.

  8. Bulbar impairment score predicts noninvasive volume-cycled ventilation failure during an acute lower respiratory tract infection in ALS.

    PubMed

    Servera, Emilio; Sancho, Jesús; Bañuls, Pilar; Marín, Julio

    2015-11-15

    Amyotrophic lateral sclerosis (ALS) patients can suffer episodes of lower respiratory tract infections (LRTI) leading to an acute respiratory failure (ARF) requiring noninvasive ventilation (NIV). To determine whether clinical or functional parameters can predict noninvasive management failure during LRTI causing ARF in ALS. A prospective study involving all ALS patients with ARF requiring NIV in a Respiratory Care Unit. NIV was provided with volume-cycled ventilators. 63 ALS patients were included (APACHE II: 14.93±3.56, Norris bulbar subscore (NBS): 18.78±9.68, ALSFRS-R: 19.90±6.98, %FVC: 40.01±18.07%, MIC: 1.62±0.74L, PCF 2.51±1.15L/s, PImax -34.90±19.44cmH2O, PEmax 51.20±28.84cmH2O). In 73.0% of patients NIV was successful in averting death or endotracheal intubation. Differences were found between the success and failure in the NBS (22.08±6.15 vs 8.66±3.39, p<0.001), ALSFRS (22.08±6.11 vs 12.71±4.39, p<0.001), PCFMI-E (3.85±0.77 vs 2.81±0.91L/s, p=0.007) and ALS onset (spinal/bulbar 33/13 vs 7/10, p=0.03). The predictor of NIV failure was the NBS (OR 0.53, 95% CI 0.31-0.92, p 0.002) with a cut-off point of 12 (S 0.93; E 0.97; PPV 0.76; NPV 0.97). NBS can predict noninvasive management failure during LRTI in ALS. Copyright © 2015 Elsevier B.V. All rights reserved.

  9. Respiratory therapies for amyotrophic lateral sclerosis: a primer.

    PubMed

    Gruis, Kirsten L; Lechtzin, Noah

    2012-09-01

    Respiratory complications are a common cause of morbidity and mortality in amyotrophic lateral sclerosis (ALS). Treatment of respiratory insufficiency with noninvasive ventilation (NIV) improves ALS patients' quality of life and survival. Evidence-based practice guidelines for the management of ALS patients recommend treatment of respiratory insufficiency with NIV as well as consideration of insufflation/exsufflation to improve clearance of airway secretions. Despite these recommendations respiratory therapies remain underused. In this review we provide a practical guide for the clinician to prescribe and manage respiratory therapies for the patient with ALS. Copyright © 2012 Wiley Periodicals, Inc.

  10. Mobile nocturnal long-term monitoring of wheezing and cough.

    PubMed

    Gross, Volker; Reinke, Christian; Dette, Frank; Koch, Roland; Vasilescu, Dragos; Penzel, Thomas; Koehler, Ulrich

    2007-02-01

    Changes in normal lung sounds are an important sign of pathophysiological processes in the bronchial system and lung tissue. For the diagnosis of bronchial asthma, coughing and wheezing are important symptoms that indicate the existence of obstruction. In particular, nocturnal long-term acoustic monitoring and assessment make sense for qualitative and quantitative detection and documentation. Previous methods used for lung function diagnosis require active patient cooperation that is not possible during sleep. We developed a mobile device based on the CORSA standard that allows the recording of respiratory sounds throughout the night. To date, we have recorded 133 patients with different diagnoses (80 male, 53 female), of whom 38 were children. In 68 of the patients we could detect cough events and in 87 we detected wheezing. The recording method was tolerated by all participating adults and children. Our mobile system allows non-invasive and cooperation-independent nocturnal monitoring of acoustic symptoms in the domestic environment, especially at night, when most ailments occur.

  11. Development of unconstrained heartbeat and respiration measurement system with pneumatic flow.

    PubMed

    Kurihara, Yosuke; Watanabe, Kajiro

    2012-12-01

    The management of health through daily monitoring of heartbeat and respiration signals is of major importance for early diagnosis to prevent diseases of the respiratory and circulatory system. However, such daily health monitoring is possible only if the monitoring system is physically and psychologically noninvasive. In this paper, an unconstrained method of measuring heartbeat and respiration signals, by using a thermistor to measure the air flows from the air mattress to an air tube accompanying the subject's heartbeat and respiration, is proposed. The SN ratio with interference by opening and closing of a door as environmental noise was compared with that obtained by the conventional condenser microphone method. As a result, the SN ratios with the condenser microphone method were 26.6 ± 4.2 dB for heartbeat and 27.8 ± 3.0 dB for respiration, whereas with the proposed method they were 34.9 ± 3.1 dB and 42.1 ± 2.5 dB, respectively.

  12. Multicomponent Breath Analysis With Infrared Absorption Using Room-Temperature Quantum Cascade Lasers

    PubMed Central

    Shorter, Joanne H.; Nelson, David D.; Barry McManus, J.; Zahniser, Mark S.; Milton, Donald K.

    2010-01-01

    Breath analysis is a powerful noninvasive technique for the diagnosis and monitoring of respiratory diseases, including asthma and chronic obstructive pulmonary disease (COPD). Nitric oxide (NO) and carbon monoxide (CO) are markers of airway inflammation and can indicate the extent of respiratory diseases. We have developed a compact fast response laser system for analysis of multiple gases by infrared absorption. The instrument uses room temperature quantum cascade lasers to simultaneously measure NO, CO, carbon dioxide (CO2) and nitrous oxide (N2O) in exhaled breath. Four breath flow rates are employed to explore their exchange dynamics in the lungs and airways. We obtain 1-s detection precisions of 0.5-0.8 parts-per-billion (ppb) for NO, CO, and N2O with an instrument response time of less than 1 s. The breath analysis system has been demonstrated in a preliminary study of volunteers. It is currently deployed in a trial clinical study. PMID:20697459

  13. Abdominal compartment syndrome related to noninvasive ventilation.

    PubMed

    De Keulenaer, Bart L; De Backer, Adelard; Schepens, Dirk R; Daelemans, Ronny; Wilmer, Alexander; Malbrain, Manu L N G

    2003-07-01

    To study the effects of noninvasive positive pressure ventilation (NIPPV) on intra-abdominal pressure. Single case report from a tertiary teaching hospital. A 65-year-old man who experienced a sudden respiratory and cardiovascular collapse during NIPPV. This was caused by gastric overdistension due to aerophagia followed by raised intra-abdominal pressure leading to intra-abdominal hypertension and abdominal compartment syndrome. The respiratory and cardiovascular problems resolved immediately after the introduction of a nasogastric tube. This resulted in normalization of IAP. This is the first case reported of an abdominal compartment syndrome related to NIPPV. Clinicians should be aware of this possible complication while using NIPPV.

  14. Non-invasive ventilation with bubble CPAP is feasible and improves respiratory physiology in hospitalised Malawian children with acute respiratory failure

    PubMed Central

    Walk, J.; Dinga, P.; Banda, C.; Msiska, T.; Chitsamba, E.; Chiwayula, N.; Lufesi, N.; Mlotha-Mitole, R.; Costello, A.; Phiri, A.; Colbourn, T.; McCollum, E. D.; Lang, H. J.

    2015-01-01

    Background In low-income countries and those with a high prevalence of HIV, respiratory failure is a common cause of death in children. However, the role of non-invasive ventilation with bubble continuous positive airway pressure (bCPAP) in these patients is not well established. Methods A prospective observational study of bCPAP was undertaken between July and September 2012 in 77 Malawian children aged 1 week to 14 years with progressive acute respiratory failure despite oxygen and antimicrobial therapy. Results Forty-one (53%) patients survived following bCPAP treatment, and an HIV-uninfected single-organ disease subgroup demonstrated bCPAP success in 14 of 17 (82%). Compared with children aged ≥60 months, infants of 0–2 months had a 93% lower odds of bCPAP failure (odds ratio 0.07, 95% confidence interval 0.004–1.02, P = 0.05). Following commencement of bCPAP, respiratory physiology improved, the average respiratory rate decreased from 61 to 49 breaths/minute (P = 0.0006), and mean oxygen saturation increased from 92.1% to 96.1% (P = 0.02). Conclusions bCPAP was well accepted by caregivers and patients and can be feasibly implemented into a tertiary African hospital with high-risk patients and limited resources. PMID:25434361

  15. Small dead space heat and moisture exchangers do not impede gas exchange during noninvasive ventilation: a comparison with a heated humidifier.

    PubMed

    Boyer, Alexandre; Vargas, Frederic; Hilbert, Gilles; Gruson, Didier; Mousset-Hovaere, Maud; Castaing, Yves; Dreyfuss, Didier; Ricard, Jean Damien

    2010-08-01

    Adverse respiratory and gasometrical effects have been described in patients with acute respiratory failure (ARF) undergoing noninvasive ventilation (NIV) with standard heat and moisture exchangers (HME). We decided to evaluate respiratory parameters and arterial blood gases (ABG) of patients during NIV with small dead space HME compared with heated humidifier (HH). Prospective randomized crossover study. A 16-bed medical intensive care unit (ICU). Fifty patients receiving NIV for ARF. The effects of HME and HH on respiratory rate, minute ventilation, EtCO(2), oxygen saturation, airway occlusion pressure at 0.1 s, ABG, and comfort perception were compared during two randomly determined NIV periods of 30 min. The relative impact of HME and HH on these parameters was successively compared with or without addition of a flex tube (40 and 10 patients, respectively). No difference was observed between HME and HH regarding any of the studied parameters, whether or not a flex tube was added. If one decides to humidify patients' airways during NIV, one may do so with small dead space HME or HH without altering respiratory parameters.

  16. Acute Respiratory Failure in Renal Transplant Recipients: A Single Intensive Care Unit Experience.

    PubMed

    Ulas, Aydin; Kaplan, Serife; Zeyneloglu, Pinar; Torgay, Adnan; Pirat, Arash; Haberal, Mehmet

    2015-11-01

    Frequency of pulmonary complications after renal transplant has been reported to range from 3% to 17%. The objective of this study was to evaluate renal transplant recipients admitted to an intensive care unit to identify incidence and cause of acute respiratory failure in the postoperative period and compare clinical features and outcomes between those with and without acute respiratory failure. We retrospectively screened the data of 540 consecutive adult renal transplant recipients who received their grafts at a single transplant center and included those patients admitted to an intensive care unit during this period for this study. Acute respiratory failure was defined as severe dyspnea, respiratory distress, decreased oxygen saturation, hypoxemia or hypercapnia on room air, or requirement of noninvasive or invasive mechanical ventilation. Among the 540 adult renal transplant recipients, 55 (10.7%) were admitted to an intensive care unit, including 26 (47.3%) admitted for acute respiratory failure. Median time from transplant to intensive care unit admission was 10 months (range, 0-67 mo). The leading causes of acute respiratory failure were bacterial pneumonia (56%) and cardiogenic pulmonary edema (44%). Mean partial pressure of arterial oxygen to fractional inspired oxygen ratio was 174 ± 59, invasive mechanical ventilation was used in 13 patients (50%), and noninvasive mechanical ventilation was used in 8 patients (31%). The overall mortality was 16.4%. Acute respiratory failure was the reason for intensive care unit admission in almost half of our renal transplant recipients. Main causes of acute respiratory failure were bacterial pneumonia and cardiogenic pulmonary edema. Mortality of patients admitted for acute respiratory failure was similar to those without acute respiratory failure.

  17. Continuous noninvasive ventilation delivered by a novel total face mask: a case series report.

    PubMed

    Belchior, Inês; Gonçalves, Miguel R; Winck, João Carlos

    2012-03-01

    Noninvasive ventilation (NIV) has been widely used to decrease the complications associated with tracheal intubation in mechanically ventilated patients. However, nasal ulcerations may occur when conventional masks are used for continuous ventilation. A total face mask, which has no contact with the more sensitive areas of the face, is a possible option. We describe 3 patients with acute respiratory failure due to amyotrophic lateral sclerosis, who developed nasal bridge skin necrosis during continuous NIV, and one patient with post-extubation respiratory failure due to a high spinal cord injury, who had facial trauma with contraindication for conventional mask use. The total face mask was very well tolerated by all the patients, and permitted safe and efficient continuous NIV for several days until the acute respiratory failure episode resolved. None of the patients required endotracheal intubation during the acute episode.

  18. Non-invasive indices for the estimation of the anaerobic threshold of oarsmen.

    PubMed

    Erdogan, A; Cetin, C; Karatosun, H; Baydar, M L

    2010-01-01

    This study compared four common non-invasive indices with an invasive index for determining the anaerobic threshold (AT) in 22 adult male rowers using a Concept2 rowing ergometer. A criterion-standard progressive incremental test (invasive method) measured blood lactate concentrations to determine the 4 mmol/l threshold (La4-AT) and Dmax AT (Dm-AT). This was compared with three indices obtained by analysis of respiratory gases and one that was based on the heart rate (HR) deflection point (HRDP) all of which used the Conconi test (non-invasive methods). In the Conconi test, the HRDP was determined whilst continuously increasing the power output (PO) by 25 W/min and measuring respiratory gases and HR. The La4-AT and Dm-AT values differed slightly with respect to oxygen uptake, PO and HR however, AT values significantly correlated with each other and with the four non-invasive methods. In conclusion, the non-invasive indices were comparable with the invasive index and could, therefore, be used in the assessment of AT during rowing ergometer use. In this population of elite rowers, Conconi threshold (Con-AT), based on the measurement of HRDP tended to be the most adequate way of estimating AT for training regulation purposes.

  19. High-Flow Nasal Cannula Oxygenation in Immunocompromised Patients With Acute Hypoxemic Respiratory Failure: A Groupe de Recherche Respiratoire en Réanimation Onco-Hématologique Study.

    PubMed

    Lemiale, Virginie; Resche-Rigon, Matthieu; Mokart, Djamel; Pène, Frédéric; Argaud, Laurent; Mayaux, Julien; Guitton, Christophe; Rabbat, Antoine; Girault, Christophe; Kouatchet, Achille; Vincent, François; Bruneel, Fabrice; Nyunga, Martine; Seguin, Amélie; Klouche, Kada; Colin, Gwenahel; Kontar, Loay; Perez, Pierre; Meert, Anne-Pascale; Benoit, Dominique D; Papazian, Laurent; Demoule, Alexandre; Chevret, Sylvie; Azoulay, Elie

    2017-03-01

    In immunocompromised patients with acute respiratory failure, invasive mechanical ventilation remains associated with high mortality. Choosing the adequate oxygenation strategy is of the utmost importance in that setting. High-flow nasal oxygen has recently shown survival benefits in unselected patients with acute respiratory failure. The objective was to assess outcomes of immunocompromised patients with hypoxemic acute respiratory failure treated with high-flow nasal oxygen. We performed a post hoc analysis of a randomized controlled trial of noninvasive ventilation in critically ill immunocompromised patients with hypoxemic acute respiratory failure. Twenty-nine ICUs in France and Belgium. Critically ill immunocompromised patients with hypoxemic acute respiratory failure. A propensity score-based approach was used to assess the impact of high-flow nasal oxygen compared with standard oxygen on day 28 mortality. Among 374 patients included in the study, 353 met inclusion criteria. Underlying disease included mostly malignancies (n = 296; 84%). Acute respiratory failure etiologies were mostly pneumonia (n = 157; 44.4%) or opportunistic infection (n = 76; 21.5%). Noninvasive ventilation was administered to 180 patients (51%). Invasive mechanical ventilation was ultimately needed in 142 patients (40.2%). Day 28 mortality was 22.6% (80 deaths). Throughout the ICU stay, 127 patients (36%) received high-flow nasal oxygen whereas 226 patients received standard oxygen. Ninety patients in each group (high-flow nasal oxygen or standard oxygen) were matched according to the propensity score, including 91 of 180 (51%) who received noninvasive ventilation. High-flow nasal oxygen was neither associated with a lower intubation rate (hazard ratio, 0.42; 95% CI, 0.11-1.61; p = 0.2) nor day 28 mortality (hazard ratio, 0.80; 95% CI, 0.45-1.42; p = 0.45). In immunocompromised patients with hypoxemic acute respiratory failure, high-flow nasal oxygen when compared with standard oxygen did not reduce intubation or survival rates. However, these results could be due to low statistical power or unknown confounders associated with the subgroup analysis. A randomized trial is needed.

  20. The predictive value of respiratory function tests for non-invasive ventilation in amyotrophic lateral sclerosis.

    PubMed

    Tilanus, T B M; Groothuis, J T; TenBroek-Pastoor, J M C; Feuth, T B; Heijdra, Y F; Slenders, J P L; Doorduin, J; Van Engelen, B G; Kampelmacher, M J; Raaphorst, J

    2017-07-25

    Non-invasive ventilation (NIV) improves survival and quality of life in amyotrophic lateral sclerosis (ALS) patients. The timing of referral to a home ventilation service (HVS), which is in part based on respiratory function tests, has shown room for improvement. It is currently unknown which respiratory function test predicts an appropriate timing of the initiation of NIV. We analysed, retrospectively, serial data of five respiratory function tests: forced vital capacity (FVC), peak cough flow (PCF), maximum inspiratory and expiratory pressure (MIP and MEP) and sniff nasal inspiratory pressure (SNIP) in patients with ALS. Patients who had had at least one assessment of respiratory function and one visit at the HVS, were included. Our aim was to detect the test with the highest predictive value for the need for elective NIV in the following 3 months. We analysed time curves, currently used cut-off values for referral, and respiratory function test results between 'NIV indication' and 'no-NIV indication' patients. One hundred ten patients with ALS were included of whom 87 received an NIV indication; 11.5% had one assessment before receiving an NIV indication, 88.5% had two or more assessments. The NIV indication was based on complaints of hypoventilation and/or proven (nocturnal) hypercapnia. The five respiratory function tests showed a descending trend during disease progression, where SNIP showed the greatest decline within the latest 3 months before NIV indication (mean = -22%). PCF at the time of referral to the HVS significantly discriminated between the groups 'NIV-indication' and 'no NIV-indication yet' patients at the first HVS visit: 259 (±92) vs. 348 (±137) L/min, p = 0.019. PCF and SNIP showed the best predictive characteristics in terms of sensitivity. SNIP showed the greatest decline prior to NIV indication and PCF significantly differentiated 'NIV-indication' from 'no NIV-indication yet' patients with ALS. Currently used cut-off values might be adjusted and other respiratory function tests such as SNIP and PCF may become part of routine care in patients with ALS in order to avoid non-timely initiation of (non-invasive) ventilation.

  1. Noninvasive Intracranial Pressure Monitoring for Severe Traumatic Brain Injury in Children: A Concise Update on Current Methods.

    PubMed

    Narayan, Vinayak; Mohammed, Nasser; Savardekar, Amey R; Patra, Devi Prasad; Notarianni, Christina; Nanda, Anil

    2018-06-01

    Traumatic brain injury (TBI) is a leading cause of pediatric morbidity and mortality worldwide and intracranial pressure (ICP) monitoring plays a crucial role in its management. Based on existing literature, we review the current practicing noninvasive ICP monitoring devices and their accuracy in predicting increased ICP in pediatric TBI. A thorough literature search was conducted on PubMed, Medline, and the Cochrane database, articles were selected systematically and reviewed completely, and relevant data were summarized and discussed. A total of 27 articles pertaining to pediatric TBI were included and reviewed. We found various modalities of noninvasive ICP monitoring devices used over the last few years. The noninvasive modalities so far attempted in pediatric TBI and so reviewed here are transcranial Doppler, optic nerve sheath diameter, otoacoustic emission, near-infrared spectroscopy, contrast-enhanced ultrasonography, and quantitative pupillometry. Invasive monitoring methods are the current gold standard for monitoring ICP; however, complications caused by their invasive nature are of concern. Of all the noninvasive methods based on the literature, we found transcranial Doppler and optic nerve sheath diameter assessment to be the best tools to monitor ICP in pediatric TBI. The promising results and developments of noninvasive ICP monitoring modalities with its ideal features of high sensitivity, diagnostic accuracy, and simple acquisition technique may make it the future of neurointensive monitoring in pediatric TBI. Copyright © 2018 Elsevier Inc. All rights reserved.

  2. Noninvasive monitoring intracranial pressure – A review of available modalities

    PubMed Central

    Khan, Marium Naveed; Shallwani, Hussain; Khan, Muhammad Ulusyar; Shamim, Muhammad Shahzad

    2017-01-01

    Background: Intracranial pressure (ICP) monitoring is important in many neurosurgical and neurological patients. The gold standard for monitoring ICP, however, is via an invasive procedure resulting in the placement of an intraventricular catheter, which is associated with many risks. Several noninvasive ICP monitoring techniques have been examined with the hope to replace the invasive techniques. The goal of this paper is to provide an overview of all modalities that have been used for noninvasive ICP monitoring to date. Methods: A thorough literature search was conducted on PubMed, selected articles were reviewed in completion, and pertinent data was included in the review. Results: A total of 94 publications were reviewed, and we found that over the past few decades clinicians have attempted to use a number of modalities to monitor ICP noninvasively. Conclusion: Although the intraventricular catheter remains the gold standard for monitoring ICP, several noninvasive modalities that can be used in settings when invasive monitoring is not possible are also available. In our opinion, measurement of optic nerve sheath diameter and pupillometry are the two modalities which may prove to be valid options for centers not performing invasive ICP monitoring. PMID:28480113

  3. Non-invasive ventilation for cancer patients with life-support techniques limitation.

    PubMed

    Meert, Anne-Pascale; Berghmans, Thierry; Hardy, Michel; Markiewicz, Eveline; Sculier, Jean-Paul

    2006-02-01

    The study was conducted to determine the usefulness and efficacy of non-invasive ventilation (NIV) in cancer patients with "life-support techniques limitation" admitted for an acute respiratory distress, in terms of intensive care unit (ICU) and hospital discharges. A total of 18 consecutive cancer patients (17 with solid tumours and one with haematological malignancy) with "life-support techniques limitation" in acute respiratory failure and who benefited from NIV were included. NIV was provided with a standard face mask by the BiPAP Vision ventilator (Respironics Inc.). Variables related to the demographic parameters, SAPS II score, cancer characteristics, intensive care data and hospital discharge were recorded. Complications leading to NIV were hypoxemic respiratory failure in 11 patients and hypercapnic respiratory failure in seven. Total median duration of NIV was 29 h. NIV was applied during a median of 2.5 days with a median of 16 h per day. Total median ICU stay was 7 days (range 1-21). Fourteen and ten patients were discharged from ICU and from hospital, respectively. NIV appears to be an effective ventilation support for cancer patients with "life-support techniques limitation".

  4. Predictors of need for noninvasive ventilation during respiratory tract infections in medically stable, non-ventilated subjects with amyotrophic lateral sclerosis.

    PubMed

    Sancho, Jesus; Servera, Emilio; Bañuls, Pilar; Marin, Julio

    2015-04-01

    Acute lower respiratory infections can impair muscle strength in patients with amyotrophic lateral sclerosis (ALS). When associated with an increase in load on the respiratory system, this situation may precipitate hypercapnic respiratory failure in non-ventilated patients with ALS. The aim of this study was to determine whether a clinical or functional parameter can predict the need for noninvasive ventilation (NIV) during an acute respiratory infection for medically stable, non-ventilated patients with ALS. This was a prospective study involving all non-ventilated subjects with ALS admitted due to an acute respiratory infection to a respiratory care unit from a tertiary hospital. Thirty-two non-ventilated subjects with ALS were admitted to our respiratory care unit due to an acute respiratory infection: 60.72 ± 10.54 y, 13 males, 23 with spinal onset, FVC of 1.58 ± 0.83 L, FVC of 56.21 ± 23.15% of predicted, peak cough flow of 3.41 ± 1.77 L/s, maximum insufflation capacity of 1.87 ± 0.94 L, revised Amyotrophic Lateral Sclerosis Functional Rating Scale score of 22.80 ± 8.83, and Norris bulbar score of 23.48 ± 12.14. Fifteen subjects required NIV during the episode. Logistic regression analysis showed that the only predictors of need for NIV were percent-of-predicted FVC (odds ratio of 1.06, 95% CI 1.01-1.11, P = .02) and peak cough flow (odds ratio of 2.57, 95% CI 1.18-5.59, P = .02). In medically stable, non-ventilated patients with ALS, measurement of percent-of-predicted FVC and peak cough flow can predict the need for NIV during an acute lower respiratory tract infection. Copyright © 2015 by Daedalus Enterprises.

  5. Non-invasive biomarkers of pulmonary damage and inflammation: Application to children exposed to ozone and trichloramine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bernard, Alfred; Carbonnelle, Sylviane; Nickmilder, Marc

    2005-08-07

    To date, airways injury or inflammation caused by air pollutants has been evaluated mainly by analysis of bronchoalveolar lavage, an invasive technique totally unsuitable to children. The assessment of respiratory risks in this particularly vulnerable population has thus for a long time relied on spirometric tests and self-reported symptoms which are relatively late and inaccurate indicators of lung damage. Research in the field of biomarkers is now opening new perspectives with the development of non-invasive tests allowing to monitor inflammation and damage in the deep lung. Blood tests measuring lung-specific proteins (pneumoproteins) such as Clara cell protein (CC16) and surfactant-associatedmore » proteins (A, B or D) are now available to evaluate the permeability and/or the cellular integrity of the pulmonary epithelium. The application of these tests to children has recently led to the discovery of a lung epithelium hyperpermeability caused by trichloramine (nitrogen trichloride), an irritant gas contaminating the air of indoor-chlorinated pools. Serum CC16 can also serve to detect increases of airway permeability during short-term exposures to ambient ozone. Indicators measurable in exhaled air such as nitric oxide (NO) appear more useful to detect airway inflammation. By applying the exhaled NO test to children attending summer camps, we recently found that ambient ozone produces an acute inflammatory response in children from levels slightly lower than current air quality guidelines. In a study exploring the links between atopy, asthma, and exposure to chlorination products in indoor pools, we also found that the exhaled NO test can serve to detect the chronic airway inflammation associated with excessive exposure to trichloramine. Lung-specific proteins measurable in serum and markers in exhaled air represent sensitive tools that can be used to assess non-invasively the effects of air pollutants on the respiratory tract of children.« less

  6. Non-invasive monitoring of pulmonary artery pressure from timing information by EIT: experimental evaluation during induced hypoxia.

    PubMed

    Proença, Martin; Braun, Fabian; Solà, Josep; Adler, Andy; Lemay, Mathieu; Thiran, Jean-Philippe; Rimoldi, Stefano F

    2016-06-01

    Monitoring of pulmonary artery pressure (PAP) in pulmonary hypertensive patients is currently limited to invasive solutions. We investigate a novel non-invasive approach for continuous monitoring of PAP, based on electrical impedance tomography (EIT), a safe, low-cost and non-invasive imaging technology. EIT recordings were performed in three healthy subjects undergoing hypoxia-induced PAP variations. The pulmonary pulse arrival time (PAT), a timing parameter physiologically linked to the PAP, was automatically calculated from the EIT signals. Values were compared to systolic PAP values from Doppler echocardiography, and yielded strong correlation scores ([Formula: see text]) for all three subjects. Results suggest the feasibility of non-invasive, unsupervised monitoring of PAP.

  7. Determinants of respiratory pump function in patients with cystic fibrosis.

    PubMed

    Dassios, Theodore

    2015-01-01

    Respiratory failure constitutes the major cause of morbidity and mortality in patients with Cystic Fibrosis (CF). Respiratory failure could either be due to lung parenchyma damage or to insufficiency of the respiratory pump which consists of the respiratory muscles, the rib cage and the neuromuscular transmission pathways. Airway obstruction, hyperinflation and malnutrition have been historically recognised as the major determinants of respiratory pump dysfunction in CF. Recent research has identified chronic infection, genetic predisposition, dietary and pharmaceutical interventions as possible additional determinants of this impairment. Furthermore, new methodological approaches in assessing respiratory pump function have led to a better understanding of the pathogenesis of respiratory pump failure in CF. Finally, respiratory muscle function could be partially preserved in CF patients with structured interventions such as aerobic exercise, inspiratory muscle training and non-invasive ventilation and CF patients could consequently be relatively protected from respiratory fatigue and respiratory failure. Copyright © 2014 Elsevier Ltd. All rights reserved.

  8. Assessment of nanoparticles and metal exposure of airport workers using exhaled breath condensate.

    PubMed

    Marie-Desvergne, Caroline; Dubosson, Muriel; Touri, Léa; Zimmermann, Eric; Gaude-Môme, Marcelline; Leclerc, Lara; Durand, Catherine; Klerlein, Michel; Molinari, Nicolas; Vachier, Isabelle; Chanez, Pascal; Mossuz, Véronique Chamel

    2016-07-13

    Aircraft engine exhaust increases the number concentration of nanoparticles (NP) in the surrounding environment. Health concerns related to NP raise the question of the exposure and health monitoring of airport workers. No biological monitoring study on this profession has been reported to date. The aim was to evaluate the NP and metal exposure of airport workers using exhaled breath condensate (EBC) as a non-invasive biological matrix representative of the respiratory tract. EBC was collected from 458 French airport workers working either on the apron or in the offices. NP exposure was characterized using particle number concentration (PNC) and size distribution. EBC particles were analyzed using dynamic light scattering (DLS) and scanning electron microscopy coupled to x-ray spectroscopy (SEM-EDS). Multi-elemental analysis was performed for aluminum (Al), cadmium (Cd) and chromium (Cr) EBC contents. Apron workers were exposed to higher PNC than administrative workers (p  <  0.001). Workers were exposed to very low particle sizes, the apron group being exposed to even smaller NP than the administrative group (p  <  0.001). The particulate content of EBC was brought out by DLS and confirmed with SEM-EDS, although no difference was found between the two study groups. Cd concentrations were higher in the apron workers (p  <  0.001), but still remained very low and close to the detection limit. Our study reported the particulate and metal content of airport workers airways. EBC is a potential useful tool for the non-invasive monitoring of workers exposed to NP and metals.

  9. A Non-Invasive Deep Tissue PH Monitor.

    DTIC Science & Technology

    1995-08-11

    disturbances in acid-base regulation may have serious effects on metabolic activity, circulation, and the central nervous system. Currently, acid-base...to tissue ischemia than is arterial pH. Consequently, a non-invasive deep tissue pH monitor has enormous value as a mechanism for rapid and effective ...achieved, and improve our understanding of what physical effects are important to successful non-invasive deep tissue pH monitoring. This last statement

  10. Noninvasive Hemodynamic Measurements During Neurosurgical Procedures in Sitting Position.

    PubMed

    Schramm, Patrick; Tzanova, Irene; Gööck, Tilman; Hagen, Frank; Schmidtmann, Irene; Engelhard, Kristin; Pestel, Gunther

    2017-07-01

    Neurosurgical procedures in sitting position need advanced cardiovascular monitoring. Transesophageal echocardiography (TEE) to measure cardiac output (CO)/cardiac index (CI) and stroke volume (SV), and invasive arterial blood pressure measurements for systolic (ABPsys), diastolic (ABPdiast) and mean arterial pressure (MAP) are established monitoring technologies for these kind of procedures. A noninvasive device for continuous monitoring of blood pressure and CO based on a modified Penaz technique (volume-clamp method) was introduced recently. In the present study the noninvasive blood pressure measurements were compared with invasive arterial blood pressure monitoring, and the noninvasive CO monitoring to TEE measurements. Measurements of blood pressure and CO were performed in 35 patients before/after giving a fluid bolus and a change from supine to sitting position, start of surgery, and repositioning from sitting to supine at the end of surgery. Data pairs from the noninvasive device (Nexfin HD) versus arterial line measurements (ABPsys, ABPdiast, MAP) and versus TEE (CO, CI, SV) were compared using Bland-Altman analysis and percentage error. All parameters compared (CO, CI, SV, ABPsys, ABPdiast, MAP) showed a large bias and wide limits of agreement. Percentage error was above 30% for all parameters except ABPsys. The noninvasive device based on a modified Penaz technique cannot replace arterial blood pressure monitoring or TEE in anesthetized patients undergoing neurosurgery in sitting position.

  11. Lung-Kidney Cross-Talk in the Critically Ill Patient.

    PubMed

    Husain-Syed, Faeq; Slutsky, Arthur S; Ronco, Claudio

    2016-08-15

    Discoveries have emerged highlighting the complex nature of the interorgan cross-talk between the kidney and the lung. Vascular rigidity, neurohormonal activation, tissue hypoxia, and abnormal immune cell signaling have been identified as common pathways leading to the development and progression of chronic kidney disease. However, our understanding of the causal relationships between lung injury and kidney injury is not precise. This review discusses a number of features and mechanisms of renal dysfunction in pulmonary disorders in relation to respiratory acidosis, impaired gas exchange, systemic congestion, respiratory support/replacement therapies, and other issues relevant to the clinical care of these patients. Biotrauma due to injurious ventilatory strategies can lead to the release of mediators into the lung, which may then translocate into the systemic circulation and cause end-organ dysfunction, including renal dysfunction. Right ventricular dysfunction and congestive states may contribute to alterations of renal perfusion and oxygenation, leading to diuretic resistance and recurrent hospitalization. In patients with concomitant respiratory failure, noninvasive ventilation represents a promising treatment option for the correction of impaired renal microcirculation and endothelial dysfunction. In patients requiring extracorporeal membrane oxygenation, short- and long-term monitoring of kidney function is warranted, as they are at highest risk of developing acute kidney injury and fluid overload.

  12. Phrenic Nerve Conduction Study in the Early Stage of Guillain-Barre Syndrome as a Predictor of Respiratory Failure.

    PubMed

    Sen, Barun Kumar; Pandit, Alak

    2018-01-01

    Guillain-Barré syndrome (GBS) has unpredictable clinical course with severe complication of respiratory failure. To identify clinical profiles and electrophysiological study particularly non-invasive Phrenic nerve conduction study in patients of early GBS to predict respiratory failure. 64 adult (age≥18yrs) patients of early GBS (onset ≤ 14 days) during the study period from January 2014 to October 2015 were evaluated by clinical profiles of age, gender, antecedent infection, time to peak disability, single breath counts, cranial nerve involvement, autonomic dysfunction and non-invasive Phrenic nerve conduction study. Patients with predisposition factors of polyneuropathy like diabetes mellitus, hypothyroidism, vitamin deficiency, renal failure were excluded. Among 64 patients abnormal phrenic nerve conduction study was seen in 65.62% cases (42/64) and 45.23% (19/42) of them developed respiratory failure. Phrenic nerve sum latency, amplitude, duration and area were abnormal in those who developed respiratory failure and they had sum of phrenic nerve latency >28 msec, sum of CMAP amplitude <300 μV, sum of CMAP duration >50 msec and sum of area < 4 mVmS. None with normal phrenic nerve study developed respiratory failure. It was found that age, gender, preceding infection, autonomic involvement and types of GB syndrome had no influence on development of respiratory failure (p>0.05). Rapid disease progression to peak disability, more severe disease, shorter single breath counts and cranial nerve involvement were seen more often in patients with respiratory failure. Abnormal Phrenic nerve conduction study in the early Guillain-Barré syndrome might be of great value independently in predicting impending respiratory failure.

  13. Phrenic Nerve Conduction Study in the Early Stage of Guillain–Barre Syndrome as a Predictor of Respiratory Failure

    PubMed Central

    Sen, Barun Kumar; Pandit, Alak

    2018-01-01

    Background: Guillain-Barré syndrome (GBS) has unpredictable clinical course with severe complication of respiratory failure. Objective: To identify clinical profiles and electrophysiological study particularly non-invasive Phrenic nerve conduction study in patients of early GBS to predict respiratory failure. Methods: 64 adult (age≥18yrs) patients of early GBS (onset ≤ 14 days) during the study period from January 2014 to October 2015 were evaluated by clinical profiles of age, gender, antecedent infection, time to peak disability, single breath counts, cranial nerve involvement, autonomic dysfunction and non-invasive Phrenic nerve conduction study. Patients with predisposition factors of polyneuropathy like diabetes mellitus, hypothyroidism, vitamin deficiency, renal failure were excluded. Results: Among 64 patients abnormal phrenic nerve conduction study was seen in 65.62% cases (42/64) and 45.23% (19/42) of them developed respiratory failure. Phrenic nerve sum latency, amplitude, duration and area were abnormal in those who developed respiratory failure and they had sum of phrenic nerve latency >28 msec, sum of CMAP amplitude <300 μV, sum of CMAP duration >50 msec and sum of area < 4 mVmS. None with normal phrenic nerve study developed respiratory failure. It was found that age, gender, preceding infection, autonomic involvement and types of GB syndrome had no influence on development of respiratory failure (p>0.05). Rapid disease progression to peak disability, more severe disease, shorter single breath counts and cranial nerve involvement were seen more often in patients with respiratory failure. Conclusion: Abnormal Phrenic nerve conduction study in the early Guillain-Barré syndrome might be of great value independently in predicting impending respiratory failure. PMID:29720799

  14. Randomized Comparison of Helmet CPAP Versus High-Flow Nasal Cannula Oxygen in Pediatric Respiratory Distress.

    PubMed

    Vitaliti, Giovanna; Vitaliti, Maria Concetta; Finocchiaro, Maria Carla; Di Stefano, Vita Antonella; Pavone, Piero; Matin, Nassim; Motamed-Gorji, Nazgol; Lubrano, Riccardo; Falsaperla, Raffaele

    2017-08-01

    The current study aimed to compare the efficacy and safety of 2 noninvasive respiratory support methods, which included helmet CPAP and high-flow nasal cannula (HFNC) in children with respiratory distress admitted to a pediatric intermediate care unit. This study was a prospective observational study conducted on children with respiratory distress (age 1-24 months) who were admitted to our acute and emergency operative unit. All included subjects were randomly treated with helmet CPAP or HFNC in a 1:1 fashion until their clinical picture, oxygen saturation, and arterial blood gas (ABG) parameters resolved. The efficiencies of helmet CPAP and HFNC were evaluated by breathing frequency, S pO 2 , ABG pH, ABG P aCO 2 , ABG P aO 2 , and P aO 2 /F IO 2 , recorded once at baseline and then after 1 and 6 h of treatment. Both noninvasive respiratory support modalities were compared with a control group of subjects with respiratory distress under standard therapeutic pharmaceutical protocols. We found that both helmet CPAP and HFNC were efficient in improving the clinical conditions of subjects with mild-to-moderate respiratory distress, although clinical response to helmet CPAP was more efficient and rapid compared with HFNC. Children who received respiratory support had a better clinical course in terms of hospitalization, days of intravenous rehydration therapy, and days of drug administration compared with the control group ( P < .001). Based on our knowledge, the present study is the first research comparing the effects of CPAP and HFNC in respiratory distress resolution in a pediatric intermediate care setting. It aims to identify the most efficient treatment to avoid pediatric ICU admissions and endotracheal intubation and reduce the administration of drugs and days of hospitalization. Copyright © 2017 by Daedalus Enterprises.

  15. Mixed acid-base disorders, hydroelectrolyte imbalance and lactate production in hypercapnic respiratory failure: the role of noninvasive ventilation.

    PubMed

    Terzano, Claudio; Di Stefano, Fabio; Conti, Vittoria; Di Nicola, Marta; Paone, Gregorino; Petroianni, Angelo; Ricci, Alberto

    2012-01-01

    Hypercapnic Chronic Obstructive Pulmonary Disease (COPD) exacerbation in patients with comorbidities and multidrug therapy is complicated by mixed acid-base, hydro-electrolyte and lactate disorders. Aim of this study was to determine the relationships of these disorders with the requirement for and duration of noninvasive ventilation (NIV) when treating hypercapnic respiratory failure. Sixty-seven consecutive patients who were hospitalized for hypercapnic COPD exacerbation had their clinical condition, respiratory function, blood chemistry, arterial blood gases, blood lactate and volemic state assessed. Heart and respiratory rates, pH, PaO(2) and PaCO(2) and blood lactate were checked at the 1st, 2nd, 6th and 24th hours after starting NIV. Nine patients were transferred to the intensive care unit. NIV was performed in 11/17 (64.7%) mixed respiratory acidosis-metabolic alkalosis, 10/36 (27.8%) respiratory acidosis and 3/5 (60%) mixed respiratory-metabolic acidosis patients (p = 0.026), with durations of 45.1 ± 9.8, 36.2 ± 8.9 and 53.3 ± 4.1 hours, respectively (p = 0.016). The duration of ventilation was associated with higher blood lactate (p<0.001), lower pH (p = 0.016), lower serum sodium (p = 0.014) and lower chloride (p = 0.038). Hyponatremia without hypervolemic hypochloremia occurred in 11 respiratory acidosis patients. Hypovolemic hyponatremia with hypochloremia and hypokalemia occurred in 10 mixed respiratory acidosis-metabolic alkalosis patients, and euvolemic hypochloremia occurred in the other 7 patients with this mixed acid-base disorder. Mixed acid-base and lactate disorders during hypercapnic COPD exacerbations predict the need for and longer duration of NIV. The combination of mixed acid-base disorders and hydro-electrolyte disturbances should be further investigated.

  16. Mixed Acid-Base Disorders, Hydroelectrolyte Imbalance and Lactate Production in Hypercapnic Respiratory Failure: The Role of Noninvasive Ventilation

    PubMed Central

    Terzano, Claudio; Di Stefano, Fabio; Conti, Vittoria; Di Nicola, Marta; Paone, Gregorino; Petroianni, Angelo; Ricci, Alberto

    2012-01-01

    Background Hypercapnic Chronic Obstructive Pulmonary Disease (COPD) exacerbation in patients with comorbidities and multidrug therapy is complicated by mixed acid-base, hydro-electrolyte and lactate disorders. Aim of this study was to determine the relationships of these disorders with the requirement for and duration of noninvasive ventilation (NIV) when treating hypercapnic respiratory failure. Methods Sixty-seven consecutive patients who were hospitalized for hypercapnic COPD exacerbation had their clinical condition, respiratory function, blood chemistry, arterial blood gases, blood lactate and volemic state assessed. Heart and respiratory rates, pH, PaO2 and PaCO2 and blood lactate were checked at the 1st, 2nd, 6th and 24th hours after starting NIV. Results Nine patients were transferred to the intensive care unit. NIV was performed in 11/17 (64.7%) mixed respiratory acidosis–metabolic alkalosis, 10/36 (27.8%) respiratory acidosis and 3/5 (60%) mixed respiratory-metabolic acidosis patients (p = 0.026), with durations of 45.1±9.8, 36.2±8.9 and 53.3±4.1 hours, respectively (p = 0.016). The duration of ventilation was associated with higher blood lactate (p<0.001), lower pH (p = 0.016), lower serum sodium (p = 0.014) and lower chloride (p = 0.038). Hyponatremia without hypervolemic hypochloremia occurred in 11 respiratory acidosis patients. Hypovolemic hyponatremia with hypochloremia and hypokalemia occurred in 10 mixed respiratory acidosis–metabolic alkalosis patients, and euvolemic hypochloremia occurred in the other 7 patients with this mixed acid-base disorder. Conclusions Mixed acid-base and lactate disorders during hypercapnic COPD exacerbations predict the need for and longer duration of NIV. The combination of mixed acid-base disorders and hydro-electrolyte disturbances should be further investigated. PMID:22539963

  17. [Noninvasive alternatives to CPAP in therapy of obstructive sleep apnea syndrome].

    PubMed

    Fritsch, K; Bloch, K E

    2000-07-01

    Non-surgical treatment of the sleep apnea syndrome comprises behavioral modification such as sleep hygiene, weight reduction, and positional training as an adjunct to standard therapy with continuous positive airway pressure (CPAP) applied via a nasal mask. For patients who cannot tolerate or are not willing to use CPAP for psychological or other reasons, removable intraoral appliances that advance the mandible during sleep are a valuable treatment alternative. Randomised controlled trials have confirmed effectiveness of intraoral appliances in relieving symptoms and measured sleep and respiratory disturbances. Side effects including hypersalivation, mucosal dryness, tooth and temporo-mandibular joint discomfort are common but usually mild. To timely detect effects of oral appliances on occlusion and on the temporo-mandibular joint longterm orthodontic monitoring is advisable.

  18. [Tracheomalacia (TM) or bronchomalacia (BM) in children: conservative or invasive therapy].

    PubMed

    Fayon, M; Donato, L

    2010-01-01

    Tracheomalacia (TM) or bronchomalacia (BM) refers to softness or weakness of the trachea or the bronchi. Its management is not evidenced-based. Conservative therapy is preferred in milder cases, since the outcome is usually favourable within the first 2 years of life. The clinical utility of non-specific treatments (anti-inflammatory agents, bronchodilators, antibiotics, physiotherapy) has not been proven by clinical trials. Treatment of symptomatic cases should be discussed on an individual basis. Airway surgery should be avoided, and non-invasive ventilation may be proposed as a temporary measure. In case of very severe cases, aortopexy, trachostomy or stent placement are the preferred treatments. Regular respiratory monitoring until remission is mandatory. Copyright 2009 Elsevier Masson SAS. All rights reserved.

  19. CFD modeling and image analysis of exhaled aerosols due to a growing bronchial tumor: Towards non-invasive diagnosis and treatment of respiratory obstructive diseases

    DOE PAGES

    Xi, Jinxiang; Kim, JongWon; Si, Xiuhua A.; ...

    2015-01-01

    Diagnosis and prognosis of tumorigenesis are generally performed with CT, PET, or biopsy. Such methods are accurate, but have the limitations of high cost and posing additional health risks to patients. In this study, we introduce an alternative computer aided diagnostic tool that can locate malignant sites caused by tumorigenesis in a non-invasive and low-cost way. Our hypothesis is that exhaled aerosol distribution is unique to lung structure and is sensitive to airway structure variations. With appropriate approaches, it is possible to locate the disease site, determine the disease severity, and subsequently formulate a targeted drug delivery plan to treatmore » the disease. This study numerically evaluated the feasibility of the proposed breath test in an image-based lung model with varying pathological stages of a bronchial squamous tumor. Large eddy simulations and a Lagrangian tracking approach were used to model respiratory airflows and aerosol dynamics. Respirations of tracer aerosols of 1 μm at a flow rate of 20 L/min were simulated, with the distributions of exhaled aerosols recorded on a filter at the mouth exit. Aerosol patterns were quantified with multiple analytical techniques such as concentration disparity, spatial scanning and fractal analysis. We demonstrated that a growing bronchial tumor induced notable variations in both the airflow and exhaled aerosol distribution. These variations became more apparent with increasing tumor severity. The exhaled aerosols exhibited distinctive pattern parameters such as spatial probability, fractal dimension, and multifractal spectrum. Results of this study show that morphometric measures of the exhaled aerosol pattern can be used to detect and monitor the pathological states of respiratory diseases in the upper airway. The proposed breath test also has the potential to locate the site of the disease, which is critical in developing a personalized, site-specific drug delivery protocol.« less

  20. CFD modeling and image analysis of exhaled aerosols due to a growing bronchial tumor: Towards non-invasive diagnosis and treatment of respiratory obstructive diseases

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xi, Jinxiang; Kim, JongWon; Si, Xiuhua A.

    Diagnosis and prognosis of tumorigenesis are generally performed with CT, PET, or biopsy. Such methods are accurate, but have the limitations of high cost and posing additional health risks to patients. In this study, we introduce an alternative computer aided diagnostic tool that can locate malignant sites caused by tumorigenesis in a non-invasive and low-cost way. Our hypothesis is that exhaled aerosol distribution is unique to lung structure and is sensitive to airway structure variations. With appropriate approaches, it is possible to locate the disease site, determine the disease severity, and subsequently formulate a targeted drug delivery plan to treatmore » the disease. This study numerically evaluated the feasibility of the proposed breath test in an image-based lung model with varying pathological stages of a bronchial squamous tumor. Large eddy simulations and a Lagrangian tracking approach were used to model respiratory airflows and aerosol dynamics. Respirations of tracer aerosols of 1 μm at a flow rate of 20 L/min were simulated, with the distributions of exhaled aerosols recorded on a filter at the mouth exit. Aerosol patterns were quantified with multiple analytical techniques such as concentration disparity, spatial scanning and fractal analysis. We demonstrated that a growing bronchial tumor induced notable variations in both the airflow and exhaled aerosol distribution. These variations became more apparent with increasing tumor severity. The exhaled aerosols exhibited distinctive pattern parameters such as spatial probability, fractal dimension, and multifractal spectrum. Results of this study show that morphometric measures of the exhaled aerosol pattern can be used to detect and monitor the pathological states of respiratory diseases in the upper airway. The proposed breath test also has the potential to locate the site of the disease, which is critical in developing a personalized, site-specific drug delivery protocol.« less

  1. CFD Modeling and Image Analysis of Exhaled Aerosols due to a Growing Bronchial Tumor: towards Non-Invasive Diagnosis and Treatment of Respiratory Obstructive Diseases

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xi, Jinxiang; Kim, JongWon; Si, Xiuhua A.

    Diagnosis and prognosis of tumorigenesis are generally performed with CT, PET, or biopsy. Such methods are accurate, but have the limitations of high cost and posing additional health risks to patients. In this study, we introduce an alternative computer aided diagnostic tool that can locate malignant sites caused by tumorigenesis in a non-invasive and low-cost way. Our hypothesis is that exhaled aerosol distribution is unique to lung structure and is sensitive to airway structure vari-ations. With appropriate approaches, it is possible to locate the disease site, determine the disease severity, and subsequently formulate a targeted drug delivery plan to treatmore » the disease. This study numerically evaluated the feasibility of the proposed breath test in an image-based lung model with varying pathological stages of a bronchial squamous tumor. Large eddy simulations and a Lagran-gian tracking approach were used to model respiratory airflows and aerosol dynamics. Respira-tions of tracer aerosols of 1 µm at a flow rate of 20 L/min were simulated, with the distributions of exhaled aerosols recorded on a filter at the mouth exit. Aerosol patterns were quantified with multiple analytical techniques such as concentration disparity, spatial scanning and fractal analysis. We demonstrated that a growing bronchial tumor induced notable variations in both the airflow and exhaled aerosol distribution. These variations became more apparent with increasing tumor severity. The exhaled aerosols exhibited distinctive pattern parameters such as spatial probability, fractal dimension, and multifractal spectrum. Results of this study show that morphometric measures of the exhaled aerosol pattern can be used to detect and monitor the pathological states of respiratory diseases in the upper airway. The proposed breath test also has the potential to locate the site of the disease, which is critical in developing a personalized, site-specific drug de-livery protocol.« less

  2. CFD Modeling and Image Analysis of Exhaled Aerosols due to a Growing Bronchial Tumor: towards Non-Invasive Diagnosis and Treatment of Respiratory Obstructive Diseases

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xi, Jinxiang; Kim, JongWon; Si, Xiuhua A.

    Diagnosis and prognosis of tumorigenesis are generally performed with CT, PET, or biopsy. Such methods are accurate, but have the limitations of high cost and posing additional health risks to patients. In this study, we introduce an alternative computer aided diagnostic tool that can locate malignant sites caused by tumorigenesis in a non-invasive and low-cost way. Our hypothesis is that exhaled aerosol distribution is unique to lung structure and is sensitive to airway structure variations. With appropriate approaches, it is possible to locate the disease site, determine the disease severity, and subsequently formulate a targeted drug delivery plan to treatmore » the disease. This study numerically evaluated the feasibility of the proposed breath test in an image-based lung model with varying pathological stages of a bronchial squamous tumor. Large eddy simulations and a Lagrangian tracking approach were used to model respiratory airflows and aerosol dynamics. Respirations of tracer aerosols of 1 µm at a flow rate of 20 L/min were simulated, with the distributions of exhaled aerosols recorded on a filter at the mouth exit. Aerosol patterns were quantified with multiple analytical techniques such as concentration disparity, spatial scanning and fractal analysis. We demonstrated that a growing bronchial tumor induced notable variations in both the airflow and exhaled aerosol distribution. These variations became more apparent with increasing tumor severity. The exhaled aerosols exhibited distinctive pattern parameters such as spatial probability, fractal dimension, and multifractal spectrum. Results of this study show that morphometric measures of the exhaled aerosol pattern can be used to detect and monitor the pathological states of respiratory diseases in the upper airway. The proposed breath test also has the potential to locate the site of the disease, which is critical in developing a personalized, site-specific drug de- livery protocol.« less

  3. Skin-like biosensor system via electrochemical channels for noninvasive blood glucose monitoring.

    PubMed

    Chen, Yihao; Lu, Siyuan; Zhang, Shasha; Li, Yan; Qu, Zhe; Chen, Ying; Lu, Bingwei; Wang, Xinyan; Feng, Xue

    2017-12-01

    Currently, noninvasive glucose monitoring is not widely appreciated because of its uncertain measurement accuracy, weak blood glucose correlation, and inability to detect hyperglycemia/hypoglycemia during sleep. We present a strategy to design and fabricate a skin-like biosensor system for noninvasive, in situ, and highly accurate intravascular blood glucose monitoring. The system integrates an ultrathin skin-like biosensor with paper battery-powered electrochemical twin channels (ETCs). The designed subcutaneous ETCs drive intravascular blood glucose out of the vessel and transport it to the skin surface. The ultrathin (~3 μm) nanostructured biosensor, with high sensitivity (130.4 μA/mM), fully absorbs and measures the glucose, owing to its extreme conformability. We conducted in vivo human clinical trials. The noninvasive measurement results for intravascular blood glucose showed a high correlation (>0.9) with clinically measured blood glucose levels. The system opens up new prospects for clinical-grade noninvasive continuous glucose monitoring.

  4. Skin-like biosensor system via electrochemical channels for noninvasive blood glucose monitoring

    PubMed Central

    Chen, Yihao; Lu, Siyuan; Zhang, Shasha; Li, Yan; Qu, Zhe; Chen, Ying; Lu, Bingwei; Wang, Xinyan; Feng, Xue

    2017-01-01

    Currently, noninvasive glucose monitoring is not widely appreciated because of its uncertain measurement accuracy, weak blood glucose correlation, and inability to detect hyperglycemia/hypoglycemia during sleep. We present a strategy to design and fabricate a skin-like biosensor system for noninvasive, in situ, and highly accurate intravascular blood glucose monitoring. The system integrates an ultrathin skin-like biosensor with paper battery–powered electrochemical twin channels (ETCs). The designed subcutaneous ETCs drive intravascular blood glucose out of the vessel and transport it to the skin surface. The ultrathin (~3 μm) nanostructured biosensor, with high sensitivity (130.4 μA/mM), fully absorbs and measures the glucose, owing to its extreme conformability. We conducted in vivo human clinical trials. The noninvasive measurement results for intravascular blood glucose showed a high correlation (>0.9) with clinically measured blood glucose levels. The system opens up new prospects for clinical-grade noninvasive continuous glucose monitoring. PMID:29279864

  5. Detecting Lung Diseases from Exhaled Aerosols: Non-Invasive Lung Diagnosis Using Fractal Analysis and SVM Classification

    PubMed Central

    Xi, Jinxiang; Zhao, Weizhong; Yuan, Jiayao Eddie; Kim, JongWon; Si, Xiuhua; Xu, Xiaowei

    2015-01-01

    Background Each lung structure exhales a unique pattern of aerosols, which can be used to detect and monitor lung diseases non-invasively. The challenges are accurately interpreting the exhaled aerosol fingerprints and quantitatively correlating them to the lung diseases. Objective and Methods In this study, we presented a paradigm of an exhaled aerosol test that addresses the above two challenges and is promising to detect the site and severity of lung diseases. This paradigm consists of two steps: image feature extraction using sub-regional fractal analysis and data classification using a support vector machine (SVM). Numerical experiments were conducted to evaluate the feasibility of the breath test in four asthmatic lung models. A high-fidelity image-CFD approach was employed to compute the exhaled aerosol patterns under different disease conditions. Findings By employing the 10-fold cross-validation method, we achieved 100% classification accuracy among four asthmatic models using an ideal 108-sample dataset and 99.1% accuracy using a more realistic 324-sample dataset. The fractal-SVM classifier has been shown to be robust, highly sensitive to structural variations, and inherently suitable for investigating aerosol-disease correlations. Conclusion For the first time, this study quantitatively linked the exhaled aerosol patterns with their underlying diseases and set the stage for the development of a computer-aided diagnostic system for non-invasive detection of obstructive respiratory diseases. PMID:26422016

  6. Vascular endothelial growth factor and amyotrophic lateral sclerosis: the interplay with exercise and noninvasive ventilation.

    PubMed

    Carilho, Rita; de Carvalho, Mamede; Swash, Michael; Pinto, Susana; Pinto, Anabela; Costa, Júlia

    2014-04-01

    We evaluated plasma vascular endothelial growth factor (VEGF) levels in patients with amyotrophic lateral sclerosis (ALS) with reference to the effects of respiratory failure, noninvasive ventilation (NIV), and exercise. We studied plasma VEGF levels in 83 ALS patients, 20 healthy controls, and 10 patients with other disorders. There were 4 groups of ALS patients: G1, 27 patients without respiratory problems; G2, 14 patients stabilized on nocturnal NIV; G3, 30 patients presenting with respiratory failure; G4, 12 patients on an aerobic exercise protocol. VEGF plasma levels did not differ significantly between ALS patients and controls, or between ALS groups. In G3, the mean VEGF levels increased 75% during NIV. In G4, the mean VEGF level increased by 300% during the exercise program. VEGF levels did not change during the course of the disease. VEGF levels in ALS depend on changes in ventilation and exercise but are probably not affected by the disease process itself. Copyright © 2013 Wiley Periodicals, Inc.

  7. Multispecies breath analysis faster than a single respiratory cycle by optical-feedback cavity-enhanced absorption spectroscopy

    NASA Astrophysics Data System (ADS)

    Ventrillard-Courtillot, Irene; Gonthiez, Thierry; Clerici, Christine; Romanini, Daniel

    2009-11-01

    We demonstrate a first application, of optical-feedback cavity-enhanced absorption spectroscopy (OF-CEAS) to breath analysis in a medical environment. Noninvasive monitoring of trace species in exhaled air was performed simultaneous to spirometric measurements on patients at Bichat Hospital (Paris). The high selectivity of the OF-CEAS spectrometer and a time response of 0.3 s (limited by sample flow rate) allowed following the evolution of carbon monoxide and methane concentrations during individual respiratory cycles, and resolving variations among different ventilatory patterns. The minimum detectable absorption on this time scale is about 3×10-10 cm-1. At the working wavelength of the instrument (2.326 μm), this translates to concentration detection limits of ~1 ppbv (45 picomolar, or ~1.25 μg/m3) for CO and 25 ppbv for CH4, well below concentration values found in exhaled air. This same instrument is also able to provide measurement of NH3 concentrations with a detection limit of ~10 ppbv however, at present, memory effects do not allow its measurement on fast time scales.

  8. Non-invasive pulmonary function test on Morquio Patients

    PubMed Central

    Kubaski, Francyne; Tomatsu, Shunji; Patel, Pravin; Shimada, Tsutomu; Xie, Li; Yasuda, Eriko; Mason, Robert; Mackenzie, William G.; Theroux, Mary; Bober, Michael B.; Oldham, Helen M.; Orii, Tadao; Shaffer, Thomas H.

    2015-01-01

    In clinical practice, respiratory function tests are difficult to perform in Morquio syndrome patients due to their characteristic skeletal dysplasia, small body size and lack of cooperation of young patients, where in some cases, conventional spirometry for pulmonary function is too challenging. To establish feasible clinical pulmonary endpoints and determine whether age impacts lung function in Morquio patients non-invasive pulmonary tests and conventional spirometry were evaluated. The non-invasive pulmonary tests: impulse oscillometry system, pneumotachography, and respiratory inductance plethysmography in conjunction with conventional spirometry were evaluated in twenty-two Morquio patients (18 Morquio A and 4 Morquio B) (7 males), ranging from 3 and 40 years of age. Twenty-two patients were compliant with non-invasive tests (100%) with exception of IOS (81.8%–18 patients). Seventeen patients (77.3%) were compliant with spirometry testing. All subjects had normal vital signs at rest including > 95% oxygen saturation, end tidal CO2 (38–44 mmHg), and age-appropriate heart rate (mean=98.3, standard deviation=19) (two patients were deviated). All patients preserved normal values in impulse oscillometry system, pneumotachography, and respiratory inductance plethysmography, although predicted forced expiratory volume total (72.8 ± 6.9 SE%) decreased with age and was below normal; phase angle (35.5 ± 16.5 Degrees), %Rib Cage (41.6 ± 12.7%), resonant frequency, and forced expiratory volume in one second/forced expiratory volume total (110.0 ± 3.2 SE%) were normal and not significantly impacted by age. The proposed non-invasive pulmonary function tests are able to cover a greater number of patients (young patients and/or wheel-chair bound), thus providing a new diagnostic approach for the assessment of lung function in Morquio syndrome which in many cases may be difficult to evaluate. Morquio patients studied herein demonstrated no clinical or functional signs of restrictive and/or obstructive lung disease. PMID:26116954

  9. Practical Insight to Monitor Home NIV in COPD Patients.

    PubMed

    Arnal, Jean-Michel; Texereau, Joëlle; Garnero, Aude

    2017-08-01

    Home noninvasive ventilation (NIV) is used in COPD patients with concomitant chronic hypercapnic respiratory failure in order to correct nocturnal hypoventilation and improve sleep quality, quality of life, and survival. Monitoring of home NIV is needed to assess the effectiveness of ventilation and adherence to therapy, resolve potential adverse effects, reinforce patient knowledge, provide maintenance of the equipment, and readjust the ventilator settings according to the changing condition of the patient. Clinical monitoring is very informative. Anamnesis focuses on the improvement of nocturnal hypoventilation symptoms, sleep quality, and side effects of NIV. Side effects are major cause of intolerance. Screening side effects leads to modification of interface, gas humidification, or ventilator settings. Home care providers maintain ventilator and interface and educate patients for correct use. However, patient's education should be supervised by specialized clinicians. Blood gas measurement shows a significant decrease in PaCO 2 when NIV is efficient. Analysis of ventilator data is very useful to assess daily use, unintentional leaks, upper airway obstruction, and patient ventilator synchrony. Nocturnal oximetry and capnography are additional monitoring tools to assess the impact of NIV on gas exchanges. In the near future, telemonitoring will reinforce and change the organization of home NIV for COPD patients.

  10. A sneak peek into digital innovations and wearable sensors for cardiac monitoring.

    PubMed

    Michard, Frederic

    2017-04-01

    Many mobile phone or tablet applications have been designed to control cardiovascular risk factors (obesity, smoking, sedentary lifestyle, diabetes and hypertension) or to optimize treatment adherence. Some have been shown to be useful but the long-term benefits remain to be demonstrated. Digital stethoscopes make easier the interpretation of abnormal heart sounds, and the development of pocket-sized echo machines may quickly and significantly expand the use of ultrasounds. Daily home monitoring of pulmonary artery pressures with wireless implantable sensors has been shown to be associated with a significant decrease in hospital readmissions for heart failure. There are more and more non-invasive, wireless, and wearable sensors designed to monitor heart rate, heart rate variability, respiratory rate, arterial oxygen saturation, and thoracic fluid content. They have the potential to change the way we monitor and treat patients with cardiovascular diseases in the hospital and beyond. Some may have the ability to improve quality of care, decrease the number of medical visits and hospitalization, and ultimately health care costs. Validation and outcome studies are needed to clarify, among the growing number of digital innovations and wearable sensors, which tools have real clinical value.

  11. Successful Deployment of High Flow Nasal Cannula in a Peruvian Pediatric Intensive Care Unit Using Implementation Science-Lessons Learned.

    PubMed

    Nielsen, Katie R; Becerra, Rosario; Mallma, Gabriela; Tantaleán da Fieno, José

    2018-01-01

    Acute lower respiratory infections are the leading cause of death outside the neonatal period for children less than 5 years of age. Widespread availability of invasive and non-invasive mechanical ventilation in resource-rich settings has reduced mortality rates; however, these technologies are not always available in many low- and middle-income countries due to the high cost and trained personnel required to implement and sustain their use. High flow nasal cannula (HFNC) is a form of non-invasive respiratory support with growing evidence for use in pediatric respiratory failure. Its simple interface makes utilization in resource-limited settings appealing, although widespread implementation in these settings lags behind resource-rich settings. Implementation science is an emerging field dedicated to closing the know-do gap by incorporating evidence-based interventions into routine care, and its principles have guided the scaling up of many global health interventions. In 2016, we introduced HFNC use for respiratory failure in a pediatric intensive care unit in Lima, Peru using implementation science methodology. Here, we review our experience in the context of the principles of implementation science to serve as a guide for others considering HFNC implementation in resource-limited settings.

  12. Official ERS/ATS clinical practice guidelines: noninvasive ventilation for acute respiratory failure

    PubMed Central

    Brochard, Laurent; Elliott, Mark W.; Hess, Dean; Hill, Nicholas S.; Navalesi, Paolo; Antonelli, Massimo; Brozek, Jan; Conti, Giorgio; Ferrer, Miquel; Guntupalli, Kalpalatha; Jaber, Samir; Keenan, Sean; Mancebo, Jordi; Mehta, Sangeeta; Raoof, Suhail

    2017-01-01

    Noninvasive mechanical ventilation (NIV) is widely used in the acute care setting for acute respiratory failure (ARF) across a variety of aetiologies. This document provides European Respiratory Society/American Thoracic Society recommendations for the clinical application of NIV based on the most current literature. The guideline committee was composed of clinicians, methodologists and experts in the field of NIV. The committee developed recommendations based on the GRADE (Grading, Recommendation, Assessment, Development and Evaluation) methodology for each actionable question. The GRADE Evidence to Decision framework in the guideline development tool was used to generate recommendations. A number of topics were addressed using technical summaries without recommendations and these are discussed in the supplementary material. This guideline committee developed recommendations for 11 actionable questions in a PICO (population–intervention–comparison–outcome) format, all addressing the use of NIV for various aetiologies of ARF. The specific conditions where recommendations were made include exacerbation of chronic obstructive pulmonary disease, cardiogenic pulmonary oedema, de novo hypoxaemic respiratory failure, immunocompromised patients, chest trauma, palliation, post-operative care, weaning and post-extubation. This document summarises the current state of knowledge regarding the role of NIV in ARF. Evidence-based recommendations provide guidance to relevant stakeholders. PMID:28860265

  13. Postoperative respiratory muscle dysfunction: pathophysiology and preventive strategies.

    PubMed

    Sasaki, Nobuo; Meyer, Matthew J; Eikermann, Matthias

    2013-04-01

    Postoperative pulmonary complications are responsible for significant increases in hospital cost as well as patient morbidity and mortality; respiratory muscle dysfunction represents a contributing factor. Upper airway dilator muscles functionally resist the upper airway collapsing forces created by the respiratory pump muscles. Standard perioperative medications (anesthetics, sedatives, opioids, and neuromuscular blocking agents), interventions (patient positioning, mechanical ventilation, and surgical trauma), and diseases (lung hyperinflation, obesity, and obstructive sleep apnea) have differential effects on the respiratory muscle subgroups. These effects on the upper airway dilators and respiratory pump muscles impair their coordination and function and can result in respiratory failure. Perioperative management strategies can help decrease the incidence of postoperative respiratory muscle dysfunction. Such strategies include minimally invasive procedures rather than open surgery, early and optimal mobilizing of respiratory muscles while on mechanical ventilation, judicious use of respiratory depressant anesthetics and neuromuscular blocking agents, and noninvasive ventilation when possible.

  14. Noninvasive Optical Monitoring of Spinal Cord Hemodynamics and Oxygenation after Acute Spinal Cord Injury

    DTIC Science & Technology

    2017-09-01

    oxygen delivery and oxygen consumption . The oxygen portion of the Oxylite probe emits short pulses of blue LED light resulting in a fluorescent...Award Number: W81XWH-16-1-0602 TITLE: Noninvasive Optical Monitoring of Spinal Cord Hemodynamics and Oxygenation after Acute Spinal Cord Injury...COVERED 1 Sep 2016 - 31 Aug 2017 4. TITLE AND SUBTITLE 5a. CONTRACT NUMBER Noninvasive Optical Monitoring of Spinal Cord Hemodynamics and Oxygenation

  15. Interdisciplinary Approaches of Transcranial Magnetic Stimulation Applied to a Respiratory Neuronal Circuitry Model

    PubMed Central

    Vinit, Stéphane; Keomani, Emilie; Deramaudt, Thérèse B.; Spruance, Victoria M.; Bezdudnaya, Tatiana; Lane, Michael A.

    2014-01-01

    Respiratory related diseases associated with the neuronal control of breathing represent life-threatening issues and to date, no effective therapeutics are available to enhance the impaired function. The aim of this study was to determine whether a preclinical respiratory model could be used for further studies to develop a non-invasive therapeutic tool applied to rat diaphragmatic neuronal circuitry. Transcranial magnetic stimulation (TMS) was performed on adult male Sprague-Dawley rats using a human figure-of-eight coil. The largest diaphragmatic motor evoked potentials (MEPdia) were recorded when the center of the coil was positioned 6 mm caudal from Bregma, involving a stimulation of respiratory supraspinal pathways. Magnetic shielding of the coil with mu metal reduced magnetic field intensities and improved focality with increased motor threshold and lower amplitude recruitment curve. Moreover, transynaptic neuroanatomical tracing with pseudorabies virus (applied to the diaphragm) suggest that connections exist between the motor cortex, the periaqueductal grey cell regions, several brainstem neurons and spinal phrenic motoneurons (distributed in the C3-4 spinal cord). These results reveal the anatomical substrate through which supraspinal stimulation can convey descending action potential volleys to the spinal motoneurons (directly or indirectly). We conclude that MEPdia following a single pulse of TMS can be successfully recorded in the rat and may be used in the assessment of respiratory supraspinal plasticity. Supraspinal non-invasive stimulations aimed to neuromodulate respiratory circuitry will enable new avenues of research into neuroplasticity and the development of therapies for respiratory dysfunction associated with neural injury and disease (e.g. spinal cord injury, amyotrophic lateral sclerosis). PMID:25406091

  16. Extracting respiratory information from seismocardiogram signals acquired on the chest using a miniature accelerometer.

    PubMed

    Pandia, Keya; Inan, Omer T; Kovacs, Gregory T A; Giovangrandi, Laurent

    2012-10-01

    Seismocardiography (SCG) is a non-invasive measurement of the vibrations of the chest caused by the heartbeat. SCG signals can be measured using a miniature accelerometer attached to the chest, and are thus well-suited for unobtrusive and long-term patient monitoring. Additionally, SCG contains information relating to both cardiovascular and respiratory systems. In this work, algorithms were developed for extracting three respiration-dependent features of the SCG signal: intensity modulation, timing interval changes within each heartbeat, and timing interval changes between successive heartbeats. Simultaneously with a reference respiration belt, SCG signals were measured from 20 healthy subjects and a respiration rate was estimated using each of the three SCG features and the reference signal. The agreement between each of the three accelerometer-derived respiration rate measurements was computed with respect to the respiration rate derived from the reference respiration belt. The respiration rate obtained from the intensity modulation in the SCG signal was found to be in closest agreement with the respiration rate obtained from the reference respiration belt: the bias was found to be 0.06 breaths per minute with a 95% confidence interval of -0.99 to 1.11 breaths per minute. The limits of agreement between the respiration rates estimated using SCG (intensity modulation) and the reference were within the clinically relevant ranges given in existing literature, demonstrating that SCG could be used for both cardiovascular and respiratory monitoring. Furthermore, phases of each of the three SCG parameters were investigated at four instances of a respiration cycle-start inspiration, peak inspiration, start expiration, and peak expiration-and during breath hold (apnea). The phases of the three SCG parameters observed during the respiration cycle were congruent with existing literature and physiologically expected trends.

  17. Monitoring gaseous exchange: implications for nursing care.

    PubMed

    Martin, Susan; Wilson, Michael

    2002-02-01

    The purpose of this study is to examine whether a relationship exists between arterial and end-tidal carbon dioxide tension (PaCO2 and PETCO2 respectively) in patients admitted to intensive care units (ICUs), and what the implications it has for nursing care. PaCO2 and PETCO2 are indicators of ventilatory adequacy which is an important aspect of respiratory function. These measures of carbon dioxide tension are obtained via invasive and non-invasive monitoring tools. Measurement of PETCO2 has only recently been introduced into ICUs and its usefulness in these environments is open to debate. A population of 30 intubated patients had 214 simultaneous measurements of PaCO2 and PETCO2 taken over a period of 10 months. The findings indicate that, despite strong significant correlations, PETCO2 cannot be used safely as a substitute for PaCO2 as the arterial/end-tidal carbon dioxide gradient is not constant, nor does capnography provide a consistently reliable indicator of PaCO2.

  18. The discriminatory value of cardiorespiratory interactions in distinguishing awake from anaesthetised states: a randomised observational study.

    PubMed

    Kenwright, D A; Bernjak, A; Draegni, T; Dzeroski, S; Entwistle, M; Horvat, M; Kvandal, P; Landsverk, S A; McClintock, P V E; Musizza, B; Petrovčič, J; Raeder, J; Sheppard, L W; Smith, A F; Stankovski, T; Stefanovska, A

    2015-12-01

    Depth of anaesthesia monitors usually analyse cerebral function with or without other physiological signals; non-invasive monitoring of the measured cardiorespiratory signals alone would offer a simple, practical alternative. We aimed to investigate whether such signals, analysed with novel, non-linear dynamic methods, would distinguish between the awake and anaesthetised states. We recorded ECG, respiration, skin temperature, pulse and skin conductivity before and during general anaesthesia in 27 subjects in good cardiovascular health, randomly allocated to receive propofol or sevoflurane. Mean values, variability and dynamic interactions were determined. Respiratory rate (p = 0.0002), skin conductivity (p = 0.03) and skin temperature (p = 0.00006) changed with sevoflurane, and skin temperature (p = 0.0005) with propofol. Pulse transit time increased by 17% with sevoflurane (p = 0.02) and 11% with propofol (p = 0.007). Sevoflurane reduced the wavelet energy of heart (p = 0.0004) and respiratory (p = 0.02) rate variability at all frequencies, whereas propofol decreased only the heart rate variability below 0.021 Hz (p < 0.05). The phase coherence was reduced by both agents at frequencies below 0.145 Hz (p < 0.05), whereas the cardiorespiratory synchronisation time was increased (p < 0.05). A classification analysis based on an optimal set of discriminatory parameters distinguished with 95% success between the awake and anaesthetised states. We suggest that these results can contribute to the design of new monitors of anaesthetic depth based on cardiovascular signals alone. © 2015 The Authors. Anaesthesia published by John Wiley & Sons Ltd on behalf of Association of Anaesthetists of Great Britain and Ireland.

  19. Development of Novel Noninvasive Methods of Stress Assessment in Baleen Whales

    DTIC Science & Technology

    2014-09-30

    large whales. Few methods exist for assessment of physiological stress levels of free-swimming cetaceans (Amaral 2010, ONR 2010, Hunt et al. 2013...hormone aldosterone . Our aim in this project is to further develop both techniques - respiratory hormone analysis and fecal hormone analysis - for use...noninvasive aldosterone assay (for both feces and blow) that can be used as an alternative measure of adrenal gland activation relative to stress

  20. Noninvasive pulmonary artery pressure monitoring by EIT: a model-based feasibility study.

    PubMed

    Proença, Martin; Braun, Fabian; Solà, Josep; Thiran, Jean-Philippe; Lemay, Mathieu

    2017-06-01

    Current monitoring modalities for patients with pulmonary hypertension (PH) are limited to invasive solutions. A novel approach for the noninvasive and unsupervised monitoring of pulmonary artery pressure (PAP) in patients with PH was proposed and investigated. The approach was based on the use of electrical impedance tomography (EIT), a noninvasive and safe monitoring technique, and was tested through simulations on a realistic 4D bio-impedance model of the human thorax. Changes in PAP were induced in the model by simulating multiple types of hypertensive conditions. A timing parameter physiologically linked to the PAP via the so-called pulse wave velocity principle was automatically estimated from the EIT data. It was found that changes in PAP could indeed be reliably monitored by EIT, irrespective of the pathophysiological condition that caused them. If confirmed clinically, these findings could open the way for a new generation of noninvasive PAP monitoring solutions for the follow-up of patients with PH.

  1. [Monitoring oxygen consumption in energy metabolism in pediatric anesthesia: clinical utility].

    PubMed

    Calvo Vecino, J M; Abad Gurumeta, A; Navarro Pérez, R; Stolle Dueñas, D; Nieto Moreno, E; De Juan García, S

    2010-01-01

    To determine changes in oxygen consumption as a marker of energy metabolism during general inhaled anesthesia in pediatric patients and to identify factors that might influence consumption. Prospective, observational, double-blind study in children under inhaled anesthesia in spontaneous ventilation. We monitored heart rate electrocardiogram, noninvasive blood pressure, respiratory frequency, carbon dioxide (CO2) end-expiratory pressure, oxygen saturation by pulse oximetry, state entropy, response entropy, esophageal temperature, and (by indirect calorimetry) oxygen consumption and the respiratory quotient. Capillary blood was extracted every 5 minutes to determine lactate concentration. Thirty-six patients (ASA 1-2) between 5 and 11 years old were included. Mean (SD) oxygen consumption was 0.6 (0.12) mL x kg(-1)min(-1) at baseline, 5.3 (03) mL x kg(-1) min(-1) during maintenance of anesthesia, and 8.1 (1.1) mL x kg(-1) min(-1) on awakening. A progressive increase was detected in lactic acid concentration, from a baseline mean of 0.8 (0.1) mmol/L to 2.2 (0.9) mmol/L half an hour later; the change was unrelated to oxygen consumption. After correcting the flow of normal saline solution to 0.9%, a significant increase in oxygen consumption (P < .05) was detected. Factors that were significantly correlated (P < 0.1 and r of +/- 0.95) were temperature (oxygen consumption decreased > 10% for each degree centigrade decrease), inspired oxygen fraction > 0.8; sharp changes in the expired CO2 fraction exceeding 2 standard deviations (+/- 6), use of nitrous oxide in the gas mix (inspired nitrous oxide fraction > 20%), the length of the sampling line, and increased respiratory frequency. A model with 3 factors was constructed to explain the kinetics of oxygen consumption during anesthesia. Oxygen consumption monitoring may provide an indirect indicator of homeostatic changes during surgery. The ideal system for carrying out such monitoring during anesthesia remains to be found, and the values to guide the anesthesiologist in deciding whether or not to intervene immediately still need to be determined.

  2. Effects of positioning on respiratory measures in individuals with cerebral palsy and severe scoliosis.

    PubMed

    Littleton, Sheila Robertson; Heriza, Carolyn B; Mullens, Pamela A; Moerchen, Victoria A; Bjornson, Kristie

    2011-01-01

    To examine the effect of positioning on respiratory measurements in individuals with cerebral palsy and severe scoliosis. Five individuals aged 17 to 37 years participated in an alternating treatment, single-subject design. Oxygen saturation, respiratory rate, heart rate, and chest wall excursion measurements were obtained in supine, sitting, and sidelying positions. Level of support for hypotheses varied on the basis of the respiratory measurement and participants' status. Respiratory rate appeared to be most sensitive to change in the positions. Severity of respiratory compromise and age may be associated with less tolerance for supine position versus sitting and sidelying positions. The use of therapeutic positioning in sitting and sidelying positions should be considered as a noninvasive intervention for a population with respiratory compromise. Further research with a larger sample is needed to empirically link specific positions with improved respiratory efficiency.

  3. Towards estimation of respiratory muscle effort with respiratory inductance plethysmography signals and complementary ensemble empirical mode decomposition.

    PubMed

    Chen, Ya-Chen; Hsiao, Tzu-Chien

    2018-07-01

    Respiratory inductance plethysmography (RIP) sensor is an inexpensive, non-invasive, easy-to-use transducer for collecting respiratory movement data. Studies have reported that the RIP signal's amplitude and frequency can be used to discriminate respiratory diseases. However, with the conventional approach of RIP data analysis, respiratory muscle effort cannot be estimated. In this paper, the estimation of the respiratory muscle effort through RIP signal was proposed. A complementary ensemble empirical mode decomposition method was used, to extract hidden signals from the RIP signals based on the frequency bands of the activities of different respiratory muscles. To validate the proposed method, an experiment to collect subjects' RIP signal under thoracic breathing (TB) and abdominal breathing (AB) was conducted. The experimental results for both the TB and AB indicate that the proposed method can be used to loosely estimate the activities of thoracic muscles, abdominal muscles, and diaphragm. Graphical abstract ᅟ.

  4. Automated acquisition system for routine, noninvasive monitoring of physiological data.

    PubMed

    Ogawa, M; Tamura, T; Togawa, T

    1998-01-01

    A fully automated, noninvasive data-acquisition system was developed to permit long-term measurement of physiological functions at home, without disturbing subjects' normal routines. The system consists of unconstrained monitors built into furnishings and structures in a home environment. An electrocardiographic (ECG) monitor in the bathtub measures heart function during bathing, a temperature monitor in the bed measures body temperature, and a weight monitor built into the toilet serves as a scale to record weight. All three monitors are connected to one computer and function with data-acquisition programs and a data format rule. The unconstrained physiological parameter monitors and fully automated measurement procedures collect data noninvasively without the subject's awareness. The system was tested for 1 week by a healthy male subject, aged 28, in laboratory-based facilities.

  5. Noninvasive ventilation in a child affected by achondroplasia respiratory difficulty syndrome.

    PubMed

    Ottonello, Giancarlo; Villa, Giovanna; Moscatelli, Andrea; Diana, Maria Cristina; Pavanello, Marco

    2007-01-01

    Achondroplasia can result in respiratory difficulty in early infancy, from anatomical abnormalities such as mid-facial hypoplasia and/or adenotonsillar hypertrophy, leading to obstructive apnea, or to pathophysiological changes occurring in nasopharyngeal or glossal muscle tone, related to neurological abnormalities (foramen magnum and/or hypoglossal canal problems, hydrocephalus), leading to central apnea. More often, the two respiratory components (central and obstructive) are both evident in mixed apnea. Polysomnographic recording should be used during preoperative and postoperative assessment of achondroplastic children and in the subsequent follow-up to assess the adequacy of continuing home respiratory support, including supplemental oxygen, bilevel positive airway pressure, or assisted ventilation.

  6. Comparison of Postoperative Respiratory Monitoring by Acoustic and Transthoracic Impedance Technologies in Pediatric Patients at Risk of Respiratory Depression.

    PubMed

    Patino, Mario; Kalin, Megan; Griffin, Allison; Minhajuddin, Abu; Ding, Lili; Williams, Timothy; Ishman, Stacey; Mahmoud, Mohamed; Kurth, C Dean; Szmuk, Peter

    2017-06-01

    In children, postoperative respiratory rate (RR) monitoring by transthoracic impedance (TI), capnography, and manual counting has limitations. The rainbow acoustic monitor (RAM) measures continuous RR noninvasively by a different methodology. Our primary aim was to compare the degree of agreement and accuracy of RR measurements as determined by RAM and TI to that of manual counting. Secondary aims include tolerance and analysis of alarm events. Sixty-two children (2-16 years old) were admitted after tonsillectomy or receiving postoperative patient/parental-controlled analgesia. RR was measured at regular intervals by RAM, TI, and manual count. Each TI or RAM alarm resulted in a clinical evaluation to categorize as a true or false alarm. To assess accuracy and degree of agreement of RR measured by RAM or TI compared with manual counting, a Bland-Altman analysis was utilized showing the average difference and the limits of agreement. Sensitivity and specificity of RR alarms by TI and RAM are presented. Fifty-eight posttonsillectomy children and 4 patient/parental-controlled analgesia users aged 6.5 ± 3.4 years and weighting 35.3 ± 22.7 kg (body mass index percentile 76.6 ± 30.8) were included. The average monitoring time per patient was 15.9 ± 4.8 hours. RAM was tolerated 87% of the total monitoring time. The manual RR count was significantly different from TI (P = .007) with an average difference ± SD of 1.39 ± 10.6 but were not significantly different from RAM (P = .81) with an average difference ± SD of 0.17 ± 6.8. The proportion of time when RR measurements differed by ≥4 breaths was 22% by TI and was 11% by RAM. Overall, 276 alarms were detected (mean alarms/patient = 4.5). The mean number of alarms per patient were 1.58 ± 2.49 and 2.87 ± 4.32 for RAM and TI, respectively. The mean number of false alarms was 0.18 ± 0.71 for RAM and 1.00 ± 2.78 for TI. The RAM was found to have 46.6% sensitivity (95% confidence interval [CI], 0.29-0.64), 95.9% specificity (95% CI, 0.90-1.00), 88.9% positive predictive value (95% CI, 0.73-1.00), and 72.1% negative predictive value (95% CI, 0.61-0.84), whereas the TI monitor had 68.5% sensitivity (95% CI, 0.53-0.84), 72.0% specificity (95% CI, 0.60-0.84), 59.0% positive (95% CI, 0.44-0.74), and 79.5% negative predictive value (95% CI, 0.69-0.90). In children at risk of postoperative respiratory depression, RR assessment by RAM was not different to manual counting. RAM was well tolerated, had a lower incidence of false alarms, and had better specificity and positive predictive value than TI. Rigorous evaluation of the negative predictive value is essential to determine the role of postoperative respiratory monitoring with RAM.

  7. Thirteen years of invasive and noninvasive home ventilation for children in a developing country: A retrospective study.

    PubMed

    Nathan, Anna Marie; Loo, Hui Yan; de Bruyne, Jessie Anne; Eg, Kah Peng; Kee, Sze Ying; Thavagnanam, Surendran; Bouniu, Marilyn; Wong, Jiat Earn; Gan, Chin Seng; Lum, Lucy Chai See

    2017-04-01

    Home ventilation (HV) for children is growing rapidly worldwide. The aim was to describe (1) the sociodemographic characteristics of children on HV and (2) the indications for, means and outcome of initiating HV in children from a developing country. This retrospective study included patients sent home on noninvasive or invasive ventilation, over 13 years, by the pediatric respiratory unit in a single center. Children who declined treatment were excluded. Seventy children were initiated on HV: 85.7% on noninvasive ventilation, 14.3% on invasive ventilation. There was about a threefold increase from 2001-2008 (n = 18) to 2009-2014 (n = 52). Median (range) age of initiating HV was 11 (1-169) months and 73% of children were <2 years old. Common indications for HV were respiratory (57.2%), chest/spine anomalies (11.4%), and neuromuscular (10.0%). Fifty-two percent came off their devices with a median (interquartile range) usage duration of 12 (4.8, 21.6) months. Ten children (14.3%) died with one avoidable death. Children with neuromuscular disease were less likely to come off their ventilator (0.0%) compared to children with respiratory disease (62.1%). Forty-one percent of parents bought their equipment, whereas 58.6% borrowed their equipment from the medical social work department and other sources. HV in a resource-limited country is possible. Children with respiratory disease made up a significant proportion of those requiring HV and were more likely to be weaned off. The mortality rate was low. The social work department played an important role in facilitating early discharge. Pediatr Pulmonol. 2017;52:500-507. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  8. Assessment of autonomic response by broad-band respiration

    NASA Technical Reports Server (NTRS)

    Berger, R. D.; Saul, J. P.; Cohen, R. J.

    1989-01-01

    We present a technique for introducing broad-band respiratory perturbations so that the response characteristics of the autonomic nervous system can be determined noninvasively over a wide range of physiologically relevant frequencies. A subject's respiratory bandwidth was broadened by breathing on cue to a sequence of audible tones spaced by Poisson intervals. The transfer function between the respiratory input and the resulting instantaneous heart rate was then computed using spectral analysis techniques. Results using this method are comparable to those found using traditional techniques, but are obtained with an economy of data collection.

  9. Optoacoustic technique for noninvasive monitoring of blood oxygenation: a feasibility study

    NASA Astrophysics Data System (ADS)

    Esenaliev, Rinat O.; Larina, Irina V.; Larin, Kirill V.; Deyo, Donald J.; Motamedi, Massoud; Prough, Donald S.

    2002-08-01

    Replacement of invasive monitoring of cerebral venous oxygenation with noninvasive techniques offers great promise in the management of life-threatening neurologic illnesses including traumatic brain injury. We developed and built an optoacoustic system to noninvasively monitor cerebral venous oxygenation; the system includes a nanosecond Nd:YAG laser and a specially designed optoacoustic probe. We tested the system in vitro in sheep blood with experimentally varied oxygenation. Our results demonstrated that (1) the amplitude and temporal profile of the optoacoustic waves increase with blood oxygenation in the range from 24% to 92%, (2) optoacoustic signals can be detected despite optical and acoustic attenuation by thick bone, and (3) the system is capable of real-time and continuous measurements. These results suggest that the optoacoustic technique is technically feasible for continuous, noninvasive monitoring of cerebral venous oxygenation.

  10. EPR spectroscopy of complex biological iron-sulfur systems.

    PubMed

    Hagen, Wilfred R

    2018-02-21

    From the very first discovery of biological iron-sulfur clusters with EPR, the spectroscopy has been used to study not only purified proteins but also complex systems such as respiratory complexes, membrane particles and, later, whole cells. In recent times, the emphasis of iron-sulfur biochemistry has moved from characterization of individual proteins to the systems biology of iron-sulfur biosynthesis, regulation, degradation, and implications for human health. Although this move would suggest a blossoming of System-EPR as a specific, non-invasive monitor of Fe/S (dys)homeostasis in whole cells, a review of the literature reveals limited success possibly due to technical difficulties in adherence to EPR spectroscopic and biochemical standards. In an attempt to boost application of System-EPR the required boundary conditions and their practical applications are explicitly and comprehensively formulated.

  11. MouthLab: A Tricorder Concept Optimized for Rapid Medical Assessment.

    PubMed

    Fridman, Gene Y; Tang, Hai; Feller-Kopman, David; Hong, Yang

    2015-09-01

    The goal of rapid medical assessment (RMA) is to estimate the general health of a patient during an emergency room or a doctor's office visit, or even while the patient is at home. Currently the devices used during RMA are typically "all-in-one" vital signs monitors. They require time, effort and expertise to attach various sensors to the body. A device optimized for RMA should instead require little effort or expertise to operate and be able to rapidly obtain and consolidate as much information as possible. MouthLab is a battery powered hand-held device intended to acquire and evaluate many measurements such as non-invasive blood sugar, saliva and respiratory biochemistry. Our initial prototype acquires standard vital signs: pulse rate (PR), breathing rate (BR), temperature (T), blood oxygen saturation (SpO2), blood pressure (BP), and a three-lead electrocardiogram. In our clinical study we tested the device performance against the measurements obtained with a standard patient monitor. 52 people participated in the study. The measurement errors were as follows: PR: -1.7 ± 3.5 BPM, BR: 0.4 ± 2.4 BPM, T: -0.4 ± 1.24 °F, SpO2: -0.6 ± 1.7%. BP systolic: -1.8 ± 12 mmHg, BP diastolic: 0.6 ± 8 mmHg. We have shown that RMA can be easily performed non-invasively by patients with no prior training.

  12. Noninvasive monitoring of gas in the lungs and intestines of newborn infants using diode lasers: feasibility study.

    PubMed

    Lundin, Patrik; Svanberg, Emilie Krite; Cocola, Lorenzo; Lewander Xu, Märta; Somesfalean, Gabriel; Andersson-Engels, Stefan; Jahr, John; Fellman, Vineta; Svanberg, Katarina; Svanberg, Sune

    2013-12-01

    Preterm newborn infants have a high morbidity rate. The most frequently affected organs where free gas is involved are the lungs and intestines. In respiratory distress syndrome, both hyperexpanded and atelectatic (collapsed) areas occur, and in necrotizing enterocolitis, intramural gas may appear in the intestine. Today, these conditions are diagnosed with x-ray radiography. A bed-side, rapid, nonintrusive, and gas-specific technique for in vivo gas sensing would improve diagnosis. We report the use of noninvasive laser spectroscopy, for the first time, to assess gas content in the lungs and intestines of three full-term infants. Water vapor and oxygen were studied with two low-power diode lasers, illuminating the skin and detecting light a few centimeters away. Water vapor was easily detected in the intestines and was also observed in the lungs. The relatively thick chest walls of the infants prevented detection of the weaker oxygen signal in this study. However, results from a previous phantom study, together with scaling of the results presented here to the typical chest-wall thickness of preterm infants, suggest that oxygen also should be detectable in their lungs.

  13. Noninvasive monitoring of gas in the lungs and intestines of newborn infants using diode lasers: feasibility study

    NASA Astrophysics Data System (ADS)

    Lundin, Patrik; Svanberg, Emilie Krite; Cocola, Lorenzo; Xu, Märta Lewander; Somesfalean, Gabriel; Andersson-Engels, Stefan; Jahr, John; Fellman, Vineta; Svanberg, Katarina; Svanberg, Sune

    2013-12-01

    Preterm newborn infants have a high morbidity rate. The most frequently affected organs where free gas is involved are the lungs and intestines. In respiratory distress syndrome, both hyperexpanded and atelectatic (collapsed) areas occur, and in necrotizing enterocolitis, intramural gas may appear in the intestine. Today, these conditions are diagnosed with x-ray radiography. A bed-side, rapid, nonintrusive, and gas-specific technique for in vivo gas sensing would improve diagnosis. We report the use of noninvasive laser spectroscopy, for the first time, to assess gas content in the lungs and intestines of three full-term infants. Water vapor and oxygen were studied with two low-power diode lasers, illuminating the skin and detecting light a few centimeters away. Water vapor was easily detected in the intestines and was also observed in the lungs. The relatively thick chest walls of the infants prevented detection of the weaker oxygen signal in this study. However, results from a previous phantom study, together with scaling of the results presented here to the typical chest-wall thickness of preterm infants, suggest that oxygen also should be detectable in their lungs.

  14. Development of Novel Noninvasive Methods of Stress Assessment in Baleen Whales

    DTIC Science & Technology

    2015-09-30

    large whales. Few methods exist for assessment of physiological stress levels of free-swimming cetaceans (Amaral 2010, ONR 2010, Hunt et al. 2013...adrenal hormone aldosterone . Our aim in this project is to further develop both techniques - respiratory hormone analysis and fecal hormone analysis...development of a noninvasive aldosterone assay (for both feces and blow) that can be used as an alternative measure of adrenal gland activation relative to

  15. Noninvasive fetal electrocardiography following intermittent umbilical cord occlusion in the preterm ovine fetus.

    PubMed

    Cleal, J K; Thomas, M; Hanson, M A; Paterson-Brown, S; Gardiner, H M; Green, L R

    2010-03-01

    To investigate whether a noninvasive fetal electrocardiography (fECG) system can identify cardiovascular responses to fetal hypoxaemia and validate the results using standard invasive fECG monitoring techniques. Prospective cohort study. Biological research facilities at The University of Southampton. Late gestation ovine fetuses; n = 5. Five fetal lambs underwent implantation of vascular catheters, umbilical cord occluder and invasive ECG chest electrodes under general anaesthesia (3% halothane/O(2)) at 119 days of gestation (term approximately 147 days of gestation). After 5 days of recovery blood pressure, blood gases, glucose and pH were monitored. At 124 and 125 days of gestation following a 10-minute baseline period a 90-second cord occlusion was applied. Noninvasive fetal ECG was recorded from maternal transabdominal electrodes using advanced signal-processing techniques, concurrently with invasive fECG recordings. Comparison of T:QRS ratios of the ECG waveform from noninvasive and invasive fECG monitoring systems. Our fECG monitoring system is able to demonstrate changes in waveforms during periods of hypoxaemia similar to those obtained invasively, which could indicate fetal distress. These findings may indicate a future use for noninvasive electrocardiography during human fetal monitoring both before and during labour in term and preterm pregnancies.

  16. Telemedicine for Facio-Scapulo-Humeral Muscular Dystrophy: A multidisciplinary approach to improve quality of life and reduce hospitalization rate?

    PubMed

    Portaro, Simona; Calabrò, Rocco Salvatore; Bramanti, Placido; Silvestri, Giuseppe; Torrisi, Michele; Conti-Nibali, Valeria; Caliri, Santina; Lunetta, Christian; Alagna, Bernardo; Naro, Antonino; Bramanti, Alessia

    2018-04-01

    Facio-Scapulo-Humeral Muscular Dystrophy (FSHD) is an autosomal dominant inherited disorder characterized by a variable and asymmetric involvement of facial, trunk, upper and lower extremity muscles. Although respiratory weakness is a relatively unknown feature of FSHD, it is not rare. Telemedicine has been used in a variety of health care fields, but only recently, with the advent of sophisticated technology, its interest among health professionals became evident, even in such diseases. To demonstrate the telemedicine efficacy in FSHD. Four siblings affected by a severe form of FSHD, living in a rural area far away from the referral center for neuromuscular diseases, who used a wheelchair, suffered from chronic respiratory failure and were provided with long-term non-invasive mechanical ventilation, received a 6-month period of telemedicine support. This consisted of video conferencing (respiratory physiotherapy, psychological support, neurological and pneumological assessment, nurse-coach supervision) and telemonitoring of cardiorespiratory variables (oxygen saturation, blood pressure, and heart rate). We performed 540 video conference sessions per patient, including three daily contacts with short monitoring oximetry measurements, blood pressure, and heart-rate measurements, psychological support, neurological and pneumological assessment, nurse-coach supervision. Our findings indicate that our telemedicine system was user-friendly, efficient for the home treatment of FSHD, and allowed reducing hospital admissions. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. Non-invasive hemoglobin monitoring.

    PubMed

    Joseph, Bellal; Haider, Ansab; Rhee, Peter

    2016-09-01

    Technology has transformed the practice of medicine and surgery in particular over the last several decades. This change in practice has allowed diagnostic and therapeutic tests to be performed less invasively. Hemoglobin monitoring remains one of the most commonly performed diagnostic tests in the United States. Recently, non-invasive hemoglobin monitoring technology has gained popularity. The aim of this article is to review the principles of how this technology works, pros and cons, and the implications of non-invasive hemoglobin technology particularly in trauma surgery. Copyright © 2015 IJS Publishing Group Ltd. Published by Elsevier Ltd. All rights reserved.

  18. Towards non-invasive characterization of breast cancer and cancer metabolism with diffuse optics

    PubMed Central

    Busch, David R.; Choe, Regine; Durduran, Turgut; Yodh, Arjun G.

    2013-01-01

    We review recent developments in diffuse optical imaging and monitoring of breast cancer, i.e. optical mammography. Optical mammography permits non-invasive, safe and frequent measurement of tissue hemodynamics oxygen metabolism and components (lipids, water, etc.), the development of new compound indices indicative of the risk and malignancy, and holds potential for frequent non-invasive longitudinal monitoring of therapy progression. PMID:24244206

  19. Survival of patients with chronic respiratory failure on long-term oxygen therapy and or non-invasive ventilation at home.

    PubMed

    Cano, Noël J; Pichard, Claude; Court-Fortune, Isabelle; Costes, Frédéric; Cynober, Luc; Gérard-Boncompain, Michèle; Molano, Luis Carlos; Cuvelier, Antoine; Laaban, Jean-Pierre; Melchior, Jean-Claude; Raphaël, Jean-Claude; France, Julie; Lloret, Thomas; Roth, Hubert; Pison, Christophe

    2015-08-01

    Chronic respiratory failure (CRF) is the common fate of respiratory diseases where systemic effects contribute to outcomes. In a prospective cohort of home-treated patients with CRF, we looked for predictors of long-term survival including respiratory, nutritional and inflammatory dimensions. 637 stable outpatients with CRF, 397 men, 68 ± 11 years, on long-term oxygen therapy and/or non-invasive ventilation from 21 chest clinics were enrolled and followed over 53 ± 31 months. CRF resulted from Chronic Obstructive Pulmonary Disease (COPD) in 48.5%, restrictive disorders 32%, mixed (obstructive and restrictive patterns) respiratory failure 13.5%, bronchiectasis 6%. Demographic characteristics, smoking habits, underlying respiratory diseases, forced expiratory volume in one second (FEV1), forced vital capacity (FVC), arterial blood gases, 6-min walking distance (6MWD), hemoglobin, body mass index (BMI), serum albumin, transthyretin, C-reactive protein (CRP), history of respiratory assistance, antibiotic and oral corticosteroid use during the previous year were recorded. 322 deaths occurred during the follow-up. One-, five- and 8-year actuarial survival was 89%, 56% and 47%. By Cox univariate analysis, age, respiratory disease, PaO2, PaCO2, FEV1/FVC, BMI, 6MWD, activity score, type and length of home respiratory assistance, smoking habits, oral corticosteroid and antibiotic uses, albumin, transthyretin, hemoglobin and CRP levels were associated with survival. Multivariate analysis identified eight independent markers of survival: age, FEV1/FVC, PaO2, PaCO2, 6MWD, BMI, serum transthyretin, CRP ≥ 5 mg/l. In CRF, whatever the underlying diseases, besides the levels of obstructive ventilatory defect and gas exchange failure, 6MWD, BMI, serum transthyretin and CRP ≥ 5 mg/l predicted long-term survival identifying potential targets for nutritional rehabilitation. Copyright © 2014 Elsevier Ltd and European Society for Clinical Nutrition and Metabolism. All rights reserved.

  20. Non-invasive carboxyhemoglobin monitoring: screening emergency medical services patients for carbon monoxide exposure.

    PubMed

    Nilson, Douglas; Partridge, Robert; Suner, Selim; Jay, Gregory

    2010-01-01

    Carbon monoxide (CO) toxicity is a significant health problem. The use of non-invasive pulse CO-oximetry screening in the emergency department has demonstrated that the rapid screening of numerous individuals for CO toxicity is simple and capable of identifying occult cases of CO toxicity. The objective of this study was to extend the use of this handheld device to the prehospital arena, assess carboxyhemoglobin (SpCO) levels in emergency medical services (EMS) patients, and correlate these levels with clinical and demographic data. This was a retrospective, observational, chart review of adult patients transported to hospital emergency departments by urban fire department EMS ambulances during a six-week period. Each ambulance used a non-invasive pulse CO-oximeter (Rad-57, Masimo Inc.) to record patients' COHb concentrations (SpCO) along with the standard EMS assessment data. Spearman's Rank Correlation tests and Student's t-tests were used to analyze the data and calculate relationships between SpCO and other variables (age, gender, respiratory rate, heart rate, mean arterial pressure, and oxygen saturation measured by pulse oximetry). A total of 36.4% of the patients transported during the study had SpCO documented. Of the 1,017 adults included in this group, 11 (1.1%) had an SpCO >15%. There was no correlation between SpCO and heart rate, ventilatory rate, mean arterial pressure, and oxygen saturation. Screening for CO toxicity in the EMS setting is possible, and may aid in the early detection and treatment of CO-poisoned patients.

  1. Development of Novel Noninvasive Methods of Stress Assessment in Baleen Whales

    DTIC Science & Technology

    2013-09-30

    adrenal hormone ( aldosterone ) that has not been adequately studied in baleen whales. Respiratory sampling is a novel method of physiological ... physiological stress levels of free-swimming cetaceans (Amaral 2010, ONR 2010, Hunt et al. 2013a). We have previously demonstrated that respiratory vapor...hormones have not yet been tested in either feces or blow, particularly aldosterone . Our aim in this project is to further develop both techniques

  2. Flexible bronchoscopy during non-invasive positive pressure mechanical ventilation: are two better than one?

    PubMed

    Scala, Raffaele

    2016-09-01

    Flexible bronchoscopy (FBO) and non-invasive positive pressure ventilation (NIPPV) are largely applied in respiratory and general intensive care units. FBO plays a crucial role for the diagnosis of lung infiltrates of unknown origin and for the treatment of airways obstruction due to bronchial mucous plugging and hemoptysis in critical patients. NIPPV is the first-choice ventilatory strategy for acute respiratory failure (ARF) of different causes as it could be used as prevention or as alternative to the conventional mechanical ventilation (CMV) via endotracheal intubation (ETI). Some clinical scenarios represent contraindications for these techniques such as severe ARF in spontaneous breathing patients for FBO and accumulated tracheo-bronchial secretions in patients with depressed cough for NIPPV. In these contexts, the decision of performing ETI should carefully consider the risk of CMV-correlated complications. An increasing amount of published data suggested the use of FBO during NIPPV in ARF in order to avoid/reduce the need of ETI. Despite a strong rationale for the combined use of the two techniques, there is not still enough evidence for a large-scale application of this strategy in all different clinical scenarios. The majority of the available data are in favor of the "help" given by NIPPV to diagnostic FBO in high-risk spontaneously breathing patients with severe hypoxemia. Preliminary findings report the successful "help" given by early FBO to NIPPV in patients with hypoxemic-hypercapnic ARF who are likely to fail because of hypersecretion. Synergy of FBO and NIPPV application is emerging also to perform ETI in challenging situations, such as predicted difficult laringoscopy and NPPV failure in severely hypoxemic patients. This combined approach should be performed only in centers showing a wide experience with both NIPPV and FBO, where close monitoring and ETI facilities are promptly available.

  3. Respiratory muscle activity and patient–ventilator asynchrony during different settings of noninvasive ventilation in stable hypercapnic COPD: does high inspiratory pressure lead to respiratory muscle unloading?

    PubMed Central

    Duiverman, Marieke L; Huberts, Anouk S; van Eykern, Leo A; Bladder, Gerrie; Wijkstra, Peter J

    2017-01-01

    Introduction High-intensity noninvasive ventilation (NIV) has been shown to improve outcomes in stable chronic obstructive pulmonary disease patients. However, there is insufficient knowledge about whether with this more controlled ventilatory mode optimal respiratory muscle unloading is provided without an increase in patient–ventilator asynchrony (PVA). Patients and methods Ten chronic obstructive pulmonary disease patients on home mechanical ventilation were included. Four different ventilatory settings were investigated in each patient in random order, each for 15 min, varying the inspiratory positive airway pressure and backup breathing frequency. With surface electromyography (EMG), activities of the intercostal muscles, diaphragm, and scalene muscles were determined. Furthermore, pressure tracings were derived simultaneously in order to assess PVA. Results Compared to spontaneous breathing, the most pronounced decrease in EMG activity was achieved with the high-pressure settings. Adding a high breathing frequency did reduce EMG activity per breath, while the decrease in EMG activity over 1 min was comparable with the high-pressure, low-frequency setting. With high backup breathing frequencies less breaths were pressure supported (25% vs 97%). PVAs occurred more frequently with the low-frequency settings (P=0.017). Conclusion High-intensity NIV might provide optimal unloading of respiratory muscles, without undue increases in PVA. PMID:28138234

  4. Respiratory muscle activity and patient-ventilator asynchrony during different settings of noninvasive ventilation in stable hypercapnic COPD: does high inspiratory pressure lead to respiratory muscle unloading?

    PubMed

    Duiverman, Marieke L; Huberts, Anouk S; van Eykern, Leo A; Bladder, Gerrie; Wijkstra, Peter J

    2017-01-01

    High-intensity noninvasive ventilation (NIV) has been shown to improve outcomes in stable chronic obstructive pulmonary disease patients. However, there is insufficient knowledge about whether with this more controlled ventilatory mode optimal respiratory muscle unloading is provided without an increase in patient-ventilator asynchrony (PVA). Ten chronic obstructive pulmonary disease patients on home mechanical ventilation were included. Four different ventilatory settings were investigated in each patient in random order, each for 15 min, varying the inspiratory positive airway pressure and backup breathing frequency. With surface electromyography (EMG), activities of the intercostal muscles, diaphragm, and scalene muscles were determined. Furthermore, pressure tracings were derived simultaneously in order to assess PVA. Compared to spontaneous breathing, the most pronounced decrease in EMG activity was achieved with the high-pressure settings. Adding a high breathing frequency did reduce EMG activity per breath, while the decrease in EMG activity over 1 min was comparable with the high-pressure, low-frequency setting. With high backup breathing frequencies less breaths were pressure supported (25% vs 97%). PVAs occurred more frequently with the low-frequency settings ( P =0.017). High-intensity NIV might provide optimal unloading of respiratory muscles, without undue increases in PVA.

  5. Sleep related respiratory events during non-invasive ventilation of patients with chronic hypoventilation.

    PubMed

    Aarrestad, Sigurd; Qvarfort, Magnus; Kleiven, Anne Louise; Tollefsen, Elin; Skjønsberg, Ole Henning; Janssens, Jean-Paul

    2017-11-01

    Non-invasive ventilation (NIV) is increasingly used in the treatment of patients with chronic hypercapnic respiratory failure (CRF). Residual sleep related respiratory events under NIV such as obstructive or central apnea/hypopnea (AH), or patient-ventilator asynchrony (PVA), may compromise treatment efficacy and/or comfort. 1/to quantify the frequency and describe the types of both AH and PVA in a large group of stable patients with CRF during night-time NIV; 2/to analyze the influence of these events on overnight pulse oximetry and transcutaneous CO 2 and 3/to assess interrater agreement in identifying and quantifying AH and PVA. We quantified AH and PVA by performing sleep polygraphy in 67 patients during elective follow-up visits. Traces were scored by two trained physicians. Residual AH were frequent: 34% of the patients had an AH Index >5/hour, with obstructive hypopnea being the most frequent event. In addition, 21% of the patients had PVA >10% of total recording time. No correlation was found between respiratory events and overnight hypercapnia. The intraclass correlation coefficients for scoring AHI and time with PVA were 0.97 (0.94-0.98) and 0.85 (0.75-0.91) respectively. Residual respiratory events are common in patients treated with long term NIV for chronic hypercapnic respiratory failure and can be scored with a very high interobserver agreement. However, these events were not associated with persistent nocturnal hypercapnia; thus, their clinical relevance has yet to be clarified. CLINICALTRIALS.GOV REGISTRATION N°: NCT01845233. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  6. Successful management of drug-induced hypercapnic acidosis with naloxone and noninvasive positive pressure ventilation.

    PubMed

    Agrafiotis, Michalis; Tryfon, Stavros; Siopi, Demetra; Chassapidou, Georgia; Galanou, Artemis; Tsara, Venetia

    2015-02-01

    A 74-year-old man was referred to our hospital due to deteriorating level of consciousness and desaturation. His Glasgow Coma Scale was 6, and his pupils were constricted but responded to light. Chest radiograph was negative for significant findings. Arterial blood gas evaluation on supplemental oxygen revealed severe acute on chronic respiratory acidosis: pH 7.15; PCO2, 133 mm Hg; PO2,64 mm Hg; and HCO3, 31 mmol/L. He regained full consciousness (Glasgow Coma Scale, 15) after receiving a 0.4 mg dose of naloxone, but because of persistent severe respiratory acidosis (pH 7.21; PCO2, 105 mm Hg), he was immediately commenced on noninvasive positive pressure ventilation (NIV) displaying a remarkable improvement in arterial blood gas values within the next few hours. However, in the days that followed, he remained dependent on NIV, and he was finally discharged on a home mechanical ventilation prescription. In cases of drug-induced respiratory depression, NIV should be regarded as an acceptable treatment, as it can provide ventilatory support without the increased risks associated with invasive mechanical ventilation.

  7. [Respiratory monitoring of pediatric patients in the Intensive Care Unit].

    PubMed

    Donoso, Alejandro; Arriagada, Daniela; Contreras, Dina; Ulloa, Daniela; Neumann, Megan

    Respiratory monitoring plays an important role in the care of children with acute respiratory failure. Therefore, its proper use and correct interpretation (recognizing which signals and variables should be prioritized) should help to a better understanding of the pathophysiology of the disease and the effects of therapeutic interventions. In addition, ventilated patient monitoring, among other determinations, allows to evaluate various parameters of respiratory mechanics, know the status of the different components of the respiratory system and guide the adjustments of ventilatory therapy. In this update, the usefulness of several techniques of respiratory monitoring including conventional respiratory monitoring and more recent methods are described. Moreover, basic concepts of mechanical ventilation, their interpretation and how the appropriate analysis of the information obtained can cause an impact on the clinical management of the patient are defined. Copyright © 2016 Hospital Infantil de México Federico Gómez. Publicado por Masson Doyma México S.A. All rights reserved.

  8. Noninvasive and cost-effective trapping method for monitoring sensitive mammal populations

    Treesearch

    Stephanie E. Trapp; Elizabeth A. Flaherty

    2017-01-01

    Noninvasive sampling methods provide a means to monitor endangered, threatened, or sensitive species or populations while increasing the efficacy of personnel effort and time. We developed a monitoring protocol that utilizes single-capture hair snares and analysis of morphological features of hair for evaluating populations. During 2015, we used the West Virginia...

  9. Agreement of Bioreactance Cardiac Output Monitoring With Thermodilution During Hemorrhagic Shock and Resuscitation in Adult Swine.

    PubMed

    Berlin, David A; Peprah-Mensah, Harrison; Manoach, Seth; Heerdt, Paul M

    2017-02-01

    The study tests the hypothesis that noninvasive cardiac output monitoring based upon bioreactance (Cheetah Medical, Portland, OR) has acceptable agreement with intermittent bolus thermodilution over a wide range of cardiac output in an adult porcine model of hemorrhagic shock and resuscitation. Prospective laboratory animal investigation. Preclinical university laboratory. Eight ~ 50 kg Yorkshire swine with a femoral artery catheter for blood pressure measurement and a pulmonary artery catheter for bolus thermodilution. With the pigs anesthetized and mechanically ventilated, 40 mL/kg of blood was removed yielding marked hypotension and a rise in plasma lactate. After 60 minutes, pigs were resuscitated with shed blood and crystalloid. Noninvasive cardiac output monitoring and intermittent thermodilution cardiac output were simultaneously measured at nine time points spanning baseline, hemorrhage, and resuscitation. Simultaneous noninvasive cardiac output monitoring and thermodilution measurements of cardiac output were compared by Bland-Altman analysis. A plot was constructed using the difference of each paired measurement expressed as a percentage of the mean of the pair plotted against the mean of the pair. Percent bias was used to scale the differences in the measurements for the magnitude of the cardiac output. Method concordance was assessed from a four-quadrant plot with a 15% zone of exclusion. Overall, noninvasive cardiac output monitoring percent bias was 1.47% (95% CI, -2.5 to 5.4) with limits of agreement of upper equal to 33.4% (95% CI, 26.5-40.2) and lower equal to -30.4% (95% CI, -37.3 to -23.6). Trending analysis demonstrated a 97% concordance between noninvasive cardiac output monitoring and thermodilution cardiac output. Over the wide range of cardiac output produced by hemorrhage and resuscitation in large pigs, noninvasive cardiac output monitoring has acceptable agreement with thermodilution cardiac output.

  10. Impact of High-flow Nasal Cannula Therapy in Quality Improvement and Clinical Outcomes in a Non-invasive Ventilation Device-free Pediatric Intensive Care Unit.

    PubMed

    Can, Fulva Kamit; Anil, Ayse Berna; Anil, Murat; Zengin, Neslihan; Bal, Alkan; Bicilioglu, Yuksel; Gokalp, Gamze; Durak, Fatih; Ince, Gulberat

    2017-10-15

    To analyze the change in quality indicators due to the use of high-flow nasal cannula therapy as a non-invasive ventilation method in children with respiratory distress/failure in a non-invasive ventilation device-free pediatric intensive care unit. Retrospective chart review of children with respiratory distress/failure admitted 1 year before (period before high-flow nasal cannula therapy) and 1 year after (period after high-flow nasal cannula therapy) the introduction of high-flow nasal cannula therapy. We compared quality indicators as rate of mechanical ventilation, total duration of mechanical ventilation, rate of re-intubation, pediatric intensive care unit length of stay, and mortality rate between these periods. Between November 2012 and November 2014, 272 patients: 141 before and 131 after high-flow nasal cannula therapy were reviewed (median age was 20.5 mo). Of the patients in the severe respiratory distress/failure subgroup, the rate of intubation was significantly lower in period after than in period before high-flow nasal cannula therapy group (58.1% vs. 76.1%; P <0.05). The median pediatric intensive care unit length of stay was significantly shorter in patients who did not require mechanical ventilation in the period after than in the period before high-flow nasal cannula therapy group (3d vs. 4d; P<0,05). Implementation of high-flow nasal cannula therapy in pediatric intensive care unit significantly improves the quality of therapy and its outcomes.

  11. Use of Advanced Machine-Learning Techniques for Non-Invasive Monitoring of Hemorrhage

    DTIC Science & Technology

    2010-04-01

    that state-of-the-art machine learning techniques when integrated with novel non-invasive monitoring technologies could detect subtle, physiological...decompensation. Continuous, non-invasively measured hemodynamic signals (e.g., ECG, blood pressures, stroke volume) were used for the development of machine ... learning algorithms. Accuracy estimates were obtained by building models using 27 subjects and testing on the 28th. This process was repeated 28 times

  12. Noninvasive glucose monitoring by optical reflective and thermal emission spectroscopic measurements

    NASA Astrophysics Data System (ADS)

    Saetchnikov, V. A.; Tcherniavskaia, E. A.; Schiffner, G.

    2005-08-01

    Noninvasive method for blood glucose monitoring in cutaneous tissue based on reflective spectrometry combined with a thermal emission spectroscopy has been developed. Regression analysis, neural network algorithms and cluster analysis are used for data processing.

  13. Noninvasive positive pressure ventilation for acute respiratory failure in delirious patients: understudied, underreported, or underappreciated? A systematic review and meta-analysis.

    PubMed

    Charlesworth, Michael; Elliott, Mark W; Holmes, John D

    2012-12-01

    We performed a systematic review and meta-analysis of the literature to determine the prevalence of delirium in patients receiving noninvasive positive pressure ventilation (NPPV) for acute respiratory failure and to quantify the prognostic impact of delirium with respect to NPPV failure. We searched the databases EMBASE (1996 to present), MEDLINE (1996 to present), PsycINFO(®) (2002 to present) and CINAHL (1992 to present). A Google™ search and hand searching of bibliographies or relevant articles were also performed. We searched for prospective observational studies conducted in a setting where patients with acute respiratory failure receiving NPPV were screened for delirium. All authors independently assessed references for inclusion and extracted data. Information was collated regarding study design, baseline characteristics of included patients, and the prevalence of delirium. Where prognostic information regarding NPPV failure was reported, a risk ratio for the association between delirium and NPPV failure was derived. These values were pooled in the meta-analysis. Three articles were retrieved by the search strategy. These included 239 patients receiving noninvasive ventilation who were assessed for delirium. The prevalence of delirium was recorded at between 33 and 38 % with a pooled prevalence of 37 %. Two studies reported prognostic data and the risk ratios for noninvasive ventilation failure in delirium were calculated as 1.79 (95 % CI 1.09-2.94) and 3.28 (95 % CI 1.60-6.73). A meta-analysis was performed and the pooled risk ratio was found to be 2.12 (95 % CI 1.41-3.18). The data in this context was scarce and of low quality. A diagnosis of delirium was made in 9 patients and inferred in 80. Despite the current lack of high-quality data and studies, the high reported prevalence of delirium and the association with noninvasive ventilation failure lends support for more awareness amongst health-care professionals and more routine screening. More focused primary research is necessary in this area. Adherence to NICE guidelines regarding delirium in these patients should be a standard of care.

  14. Non-invasive ventilation during cycle exercise training in patients with chronic respiratory failure on long-term ventilatory support: A randomized controlled trial.

    PubMed

    Vitacca, Michele; Kaymaz, Dicle; Lanini, Barbara; Vagheggini, Guido; Ergün, Pınar; Gigliotti, Francesco; Ambrosino, Nicolino; Paneroni, Mara

    2018-02-01

    The role of non-invasive ventilation (NIV) during exercise training (ET) in patients with chronic respiratory failure (CRF) is still unclear. The aim of this study was to test whether NIV during ET had an additional effect in increasing the 6-min walking distance (6MWD) and cycle endurance time compared with ET alone. All patients underwent 20 sessions of cycle training over 3 weeks and were randomly assigned to ET with NIV or ET alone. Outcome measures were 6MWD (primary outcome), incremental and endurance cycle ergometer exercise time, respiratory muscle function, quality of life by the Maugeri Respiratory Failure questionnaire (MRF-28), dyspnoea (Medical Research Council scale) and leg fatigue at rest. Forty-two patients completed the study. Following training, no significant difference in 6MWD changes were found between groups. Improvement in endurance time was significantly greater in the NIV group compared with the non-NIV training group (754 ± 973 vs 51 ± 406 s, P = 0.0271); dyspnoea improved in both groups, while respiratory muscle function and leg fatigue improved only in the NIV ET group. MRF-28 improved only in the group training without NIV. In CRF patients on long-term NIV and long-term oxygen therapy (LTOT), the addition of NIV to ET sessions resulted in an improvement in endurance time, but not in 6MWD. © 2017 Asian Pacific Society of Respirology.

  15. Non-invasive ventilation after cardiac surgery outside the Intensive Care Unit.

    PubMed

    Olper, L; Cabrini, L; Landoni, G; Rossodivita, A; Nobile, L; Monti, G; Alfieri, O; Zangrillo, A

    2011-01-01

    Non-invasive ventilation (NIV) can prevent or treat postoperative acute respiratory failure. NIV after discharge from the Intensive Care Unit (ICU) has never been described in the setting of cardiac surgery. This study enrolled 85 patients who received NIV in the main ward as treatment for respiratory failure. The patients had the following conditions: atelectasis (45 patients), pleural effusion (20 patients), pulmonary congestion (13 patients), diaphragm hemiparesis (6 patients), pneumonia (4 patients) or a combination of these conditions. Eighty-three patients were discharged from the hospital in good condition and without need for further NIV treatment, while two died in-hospital. Four of the 85 patients had an immediate NIV failure, while eight patients had delayed NIV failure. Only one patient had a NIV-related complication represented by hypotension after NIV institution. In this patient, NIV was interrupted with no consequences. Major mistakes were mask malpositioning with excessive air leaks (7 patients), incorrect preparation of the circuit (one patient), and oxygen tube disconnection (one patient). Minor mistakes (sub-optimal positioning of the face mask without excessive air leaks) were noted by the respiratory therapists for all patients and were managed by slightly modifying the mask position. In our experience, postoperative NIV is feasible, safe and effective in treating postoperative acute respiratory failure when applied in the cardiac surgical ward, preserving intensive care unit beds for surgical activity. A respiratory therapy service managed the treatment in conjunction with ward nurses, while an anesthesiologist and a cardiologist served as consultants.

  16. Oral appliance to assist non-invasive ventilation in a patient with amyotrophic lateral sclerosis.

    PubMed

    Veldhuis, Steffanie K B; Doff, Michiel H J; Stegenga, Boudewijn; Nieuwenhuis, Jellie A; Wijkstra, Peter J

    2015-03-01

    From the moment the respiratory muscle groups are affected in amyotrophic lateral sclerosis (ALS), respiratory complications will be the major cause of morbidity and mortality. Untreated respiratory muscle impairment leads to respiratory insufficiency and additionally to difficulties in airway secretion clearance. Non-invasive ventilation (NIV) is the first choice in treating respiratory insufficiency in ALS as it improves sleep-related symptoms, quality of life and life expectancy. Nevertheless, NIV is not always effective, probably due to bulbar dysfunction or anatomical abnormalities. As a result, tracheostomy ventilation (TV) may become necessary. In this case report, we present a 60-year-old female with ALS, for whom it was not possible to provide a sufficient tidal volume with NIV. A chin lift was performed while the patient was awake to see if a more anterior jaw position would lead to an increased tidal volume. As this was the case, a mandibular advancement device (MAD) was fabricated. With a combination of a MAD and NIV, the upper airway obstructions were overcome and a good ventilation and adherence to therapy were seen. When there is the presumption of airway obstructions in combination with an ineffective NIV, we advise to perform a chin lift to assess whether the obstructions can be overcome by a more anterior jaw position. If that is the case, NIV may be combined with MAD to establish effective ventilation and avoid the use of TV.

  17. Dual-Color Monitoring Overcomes the Limitations of Single Bioluminescent Reporters in Fast-Growing Microbes and Reveals Phase-Dependent Protein Productivity during the Metabolic Rhythms of Saccharomyces cerevisiae

    PubMed Central

    Krishnamoorthy, Archana

    2015-01-01

    Luciferase is a useful, noninvasive reporter of gene regulation that can be continuously monitored over long periods of time; however, its use is problematic in fast-growing microbes like bacteria and yeast because rapidly changing cell numbers and metabolic states also influence bioluminescence, thereby confounding the reporter's signal. Here we show that these problems can be overcome in the budding yeast Saccharomyces cerevisiae by simultaneously monitoring bioluminescence from two different colors of beetle luciferase, where one color (green) reports activity of a gene of interest, while a second color (red) is stably expressed and used to continuously normalize green bioluminescence for fluctuations in signal intensity that are unrelated to gene regulation. We use this dual-luciferase strategy in conjunction with a light-inducible promoter system to test whether different phases of yeast respiratory oscillations are more suitable for heterologous protein production than others. By using pulses of light to activate production of a green luciferase while normalizing signal variation to a red luciferase, we show that the early reductive phase of the yeast metabolic cycle produces more luciferase than other phases. PMID:26162874

  18. Development of Non-contact Respiratory Monitoring System for Newborn Using a FG Vision Sensor

    NASA Astrophysics Data System (ADS)

    Kurami, Yoshiyuki; Itoh, Yushi; Natori, Michiya; Ohzeki, Kazuo; Aoki, Yoshimitsu

    In recent years, development of neonatal care is strongly hoped, with increase of the low-birth-weight baby birth rate. Especially respiration of low-birth-weight baby is incertitude because central nerve and respiratory function is immature. Therefore, a low-birth-weight baby often causes a disease of respiration. In a NICU (Neonatal Intensive Care Unit), neonatal respiration is monitored using cardio-respiratory monitor and pulse oximeter at all times. These contact-type sensors can measure respiratory rate and SpO2 (Saturation of Peripheral Oxygen). However, because a contact-type sensor might damage the newborn's skin, it is a real burden to monitor neonatal respiration. Therefore, we developed the respiratory monitoring system for newborn using a FG (Fiber Grating) vision sensor. FG vision sensor is an active stereo vision sensor, it is possible for non-contact 3D measurement. A respiratory waveform is calculated by detecting the vertical motion of the thoracic and abdominal region with respiration. We attempted clinical experiment in the NICU, and confirmed the accuracy of the obtained respiratory waveform was high. Non-contact respiratory monitoring of newborn using a FG vision sensor enabled the minimally invasive procedure.

  19. Initial evaluation of the use of USPIO cell labeling and noninvasive MR monitoring of human tissue-engineered vascular grafts in vivo.

    PubMed

    Nelson, G N; Roh, J D; Mirensky, T L; Wang, Y; Yi, T; Tellides, G; Pober, J S; Shkarin, P; Shapiro, E M; Saltzman, W M; Papademetris, X; Fahmy, T M; Breuer, C K

    2008-11-01

    This pilot study examines noninvasive MR monitoring of tissue-engineered vascular grafts (TEVGs) in vivo using cells labeled with iron oxide nanoparticles. Human aortic smooth muscle cells (hASMCs) were labeled with ultrasmall superparamagnetic iron oxide (USPIO) nanoparticles. The labeled hASMCs, along with human aortic endothelial cells, were incorporated into eight TEVGs and were then surgically implanted as aortic interposition grafts in a C.B-17 SCID/bg mouse host. USPIO-labeled hASMCs persisted in the grafts throughout a 3 wk observation period and allowed noninvasive MR imaging of the human TEVGs for real-time, serial monitoring of hASMC retention. This study demonstrates the feasibility of applying noninvasive imaging techniques for evaluation of in vivo TEVG performance.

  20. Optical coherence tomography technique for noninvasive blood glucose monitoring: phantom, animal, and human studies

    NASA Astrophysics Data System (ADS)

    Larin, Kirill V.; Ashitkov, Taras V.; Larina, Irina V.; Petrova, Irina Y.; Eledrisi, Mohsen S.; Motamedi, Massoud; Esenaliev, Rinat O.

    2002-06-01

    Continuous noninvasive monitoring of blood glucose concentration can improve management of Diabetes Mellitus, reduce mortality, and considerably improve quality of life of diabetic patients. Recently, we proposed to use the OCT technique for noninvasive glucose monitoring. In this paper, we tested noninvasive blood glucose monitoring with the OCT technique in phantoms, animals, and human subjects. An OCT system with the wavelength of 1300 nm was used in our experiments. Phantom studies performed on aqueous suspensions of polystyrene microspheres and milk showed 3.2% decrease of exponential slope of OCT signals when glucose concentration increased from 0 to 100 mM. Theoretical calculations based on the Mie theory of scattering support the results obtained in phantoms. Bolus glucose injections and glucose clamping experiments were performed in animals (New Zealand rabbits and Yucatan micropigs). Good correlation between changes in the OCT signal slope and actual blood glucose concentration were observed in these experiments. First studies were performed in healthy human subjects (using oral glucose tolerance tests). Dependence of the slope of the OCT signals on the actual blood glucose concentration was similar to that obtained in animal studies. Our studies suggest that the OCT technique can potentially be used for noninvasive blood glucose monitoring.

  1. Development of Less Toxic Treatment Strategies for Metastatic and Drug-Resistant Breast Cancer Using Noninvasive Optical Monitoring

    DTIC Science & Technology

    2016-09-01

    AWARD NUMBER: W81XWH-15-1-0070 TITLE: Development of Less Toxic Treatment Strategies for Metastatic and Drug- Resistant Breast Cancer Using...0070 Development of Less Toxic Treatment Strategies for Metastatic and Drug- Resistant Breast Cancer Using Noninvasive Optical Monitori g 5c. PROGRAM...drug resistant breast cancer. Non-invasive Diffuse Optical Imaging technologies are able to monitor drug response and resistance through quantitative

  2. Multi-modality image registration for effective thermographic fever screening

    NASA Astrophysics Data System (ADS)

    Dwith, C. Y. N.; Ghassemi, Pejhman; Pfefer, Joshua; Casamento, Jon; Wang, Quanzeng

    2017-02-01

    Fever screening based on infrared thermographs (IRTs) is a viable mass screening approach during infectious disease pandemics, such as Ebola and Severe Acute Respiratory Syndrome (SARS), for temperature monitoring in public places like hospitals and airports. IRTs have been found to be powerful, quick and non-invasive methods for detecting elevated temperatures. Moreover, regions medially adjacent to the inner canthi (called the canthi regions in this paper) are preferred sites for fever screening. Accurate localization of the canthi regions can be achieved through multi-modality registration of infrared (IR) and white-light images. Here we propose a registration method through a coarse-fine registration strategy using different registration models based on landmarks and edge detection on eye contours. We have evaluated the registration accuracy to be within +/- 2.7 mm, which enables accurate localization of the canthi regions.

  3. Southwest Research Institute assistance to NASA in biomedical areas of the technology

    NASA Technical Reports Server (NTRS)

    Culclasure, D. F.; Eckhardt, L.

    1971-01-01

    Significant applications of aerospace technology were achieved. These applications include: a miniaturized, noninvasive system to telemeter electrocardiographic signals of heart transplant patients during their recuperative period as graded situations are introduced; and economical vital signs monitor for use in nursing homes and rehabilitation hospitals to indicate the onset of respiratory arrest; an implantable telemetry system to indicate the onset of the rejection phenomenon in animals undergoing cardiac transplants; an exceptionally accurate current proportional temperature controller for pollution studies; an automatic, atraumatic blood pressure measurement device; materials for protecting burned areas in contact with joint bender splints; a detector to signal the passage of animals by a given point during ecology studies; and special cushioning for use with below-knee amputees to protect the integrity of the skin at the stump/prosthesis interface.

  4. Trends in Nanomaterial-Based Non-Invasive Diabetes Sensing Technologies

    PubMed Central

    Makaram, Prashanth; Owens, Dawn; Aceros, Juan

    2014-01-01

    Blood glucose monitoring is considered the gold standard for diabetes diagnostics and self-monitoring. However, the underlying process is invasive and highly uncomfortable for patients. Furthermore, the process must be completed several times a day to successfully manage the disease, which greatly contributes to the massive need for non-invasive monitoring options. Human serums, such as saliva, sweat, breath, urine and tears, contain traces of glucose and are easily accessible. Therefore, they allow minimal to non-invasive glucose monitoring, making them attractive alternatives to blood measurements. Numerous developments regarding noninvasive glucose detection techniques have taken place over the years, but recently, they have gained recognition as viable alternatives, due to the advent of nanotechnology-based sensors. Such sensors are optimal for testing the amount of glucose in serums other than blood thanks to their enhanced sensitivity and selectivity ranges, in addition to their size and compatibility with electronic circuitry. These nanotechnology approaches are rapidly evolving, and new techniques are constantly emerging. Hence, this manuscript aims to review current and future nanomaterial-based technologies utilizing saliva, sweat, breath and tears as a diagnostic medium for diabetes monitoring. PMID:26852676

  5. Trends in Nanomaterial-Based Non-Invasive Diabetes Sensing Technologies.

    PubMed

    Makaram, Prashanth; Owens, Dawn; Aceros, Juan

    2014-04-21

    Blood glucose monitoring is considered the gold standard for diabetes diagnostics and self-monitoring. However, the underlying process is invasive and highly uncomfortable for patients. Furthermore, the process must be completed several times a day to successfully manage the disease, which greatly contributes to the massive need for non-invasive monitoring options. Human serums, such as saliva, sweat, breath, urine and tears, contain traces of glucose and are easily accessible. Therefore, they allow minimal to non-invasive glucose monitoring, making them attractive alternatives to blood measurements. Numerous developments regarding noninvasive glucose detection techniques have taken place over the years, but recently, they have gained recognition as viable alternatives, due to the advent of nanotechnology-based sensors. Such sensors are optimal for testing the amount of glucose in serums other than blood thanks to their enhanced sensitivity and selectivity ranges, in addition to their size and compatibility with electronic circuitry. These nanotechnology approaches are rapidly evolving, and new techniques are constantly emerging. Hence, this manuscript aims to review current and future nanomaterial-based technologies utilizing saliva, sweat, breath and tears as a diagnostic medium for diabetes monitoring.

  6. Effect of varying the pressurisation rate during noninvasive pressure support ventilation.

    PubMed

    Prinianakis, G; Delmastro, M; Carlucci, A; Ceriana, P; Nava, S

    2004-02-01

    The aim of the study was to assess the effects of varying the pressurisation rate during noninvasive pressure support ventilation on patients' breathing pattern, inspiratory effort, arterial blood gases, tolerance to ventilation and amount of air leakage. A total of 15 chronic obstructive pulmonary disease patients recovering from an acute episode of hypercapnic acute respiratory failure were studied during four randomised trials with different levels of pressurisation rate. No significant changes were observed in breathing pattern and arterial blood gases between the different runs. The pressure time product of the diaphragm, an estimate of its metabolic consumption, was significantly lower with all pressurisation rates than with spontaneous breathing, but was significantly lowest with the fastest rate. However, air leak, assessed by the ratio between expired and inspired tidal volumes, increased and the patients' tolerance of ventilation, measured using a standardised scale, was significantly poorer with the fastest pressurisation rate. In chronic obstructive pulmonary disease patients recovering from an episode of acute hypercapnic respiratory failure and ventilated with noninvasive pressure support ventilation, different pressurisation rates resulted in different reductions in the pressure time product of the diaphragm; this reduction was greater with the fastest rate, but was accompanied by significant air leaks and poor tolerance.

  7. State of the Art: Neonatal Non-invasive Respiratory Support: Physiological Implications

    PubMed Central

    Shaffer, Thomas H.; Alapati, Deepthi; Greenspan, Jay S.; Wolfson, Marla R.

    2013-01-01

    Summary The introduction of assisted ventilation for neonatal pulmonary insufficiency has resulted in the successful treatment of many previously fatal diseases. During the past three decades, refinement of invasive mechanical ventilation techniques has dramatically improved survival of many high-risk neonates. However, as with many advances in medicine, while mortality has been reduced, morbidity has increased in the surviving high-risk neonate. In this regard, introduction of assisted ventilation has been associated with chronic lung injury, also known as bronchopulmonary dysplasia. This disease, unknown prior to the appearance of mechanical ventilation, has produced a population of patients characterized by ventilator or oxygen dependence with serious accompanying pulmonary and neurodevelopmental morbidity. The purpose of this article is to review non-invasive respiratory support methodologies to address the physiologic mechanisms by which these methods may prevent the pathophysiologic effects of invasive mechanical ventilation. PMID:22777738

  8. [Non-invasive mechanical ventilation with a facial interface during sedation for a percutaneous endoscopic gastrostomy in a patient with amyotrophic lateral sclerosis].

    PubMed

    González-Frasquet, M C; García-Covisa, N; Vidagany-Espert, L; Herranz-Gordo, A; Llopis-Calatayud, J E

    2015-11-01

    Amyotrophic lateral sclerosis is a chronic neurodegenerative disease of the central nervous system which affects the motor neurons and produces a progressive muscle weakness, leading to atrophy and muscle paralysis, and ultimately death. Performing a percutaneous endoscopic gastrostomy with sedation in patients with amyotrophic lateral sclerosis can be a challenge for the anesthesiologist. The case is presented of a 76-year-old patient who suffered from advanced stage amyotrophic lateral sclerosis, ASA III, in which a percutaneous endoscopic gastrostomy was performed with deep sedation, for which non-invasive ventilation was used as a respiratory support to prevent hypoventilation and postoperative respiratory complications. Copyright © 2014 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Publicado por Elsevier España, S.L.U. All rights reserved.

  9. The value of non-invasive ventilation.

    PubMed

    Hull, Jeremy

    2014-11-01

    Non-invasive ventilation (NIV) use has increased markedly over the last 10 years. Children being treated with NIV are now a common sight in most paediatric intensive care units and high dependency units and nearly all tertiary respiratory units will look after a cohort of children who use NIV at home. Although the published evidence base for use of NIV in acute and chronic respiratory failure is relatively weak, it is now very unlikely that there will be any more randomised controlled trials of this intervention. Effectiveness of NIV will need to be evaluated on each child as it used. It is important to define the purpose of using NIV in each child, and then determine whether it is effective. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  10. The role of non-invasive biomarkers in detecting acute respiratory effects of traffic-related air pollution.

    PubMed

    Scarpa, M C; Kulkarni, N; Maestrelli, P

    2014-09-01

    The role of non-invasive methods in the investigation of acute effects of traffic-related air pollution is not clearly established. We evaluated the usefulness of non-invasive biomarkers in detecting acute air pollution effects according to the age of participants, the disease status, their sensitivity compared with lung function tests and their specificity for a type of pollutant. Search terms lead to 535 titles, among them 128 had potentially relevant abstracts. Sixtynine full papers were reviewed, while 59 articles were excluded as they did not meet the selection criteria. Methods used to assess short-term effects of air pollution included analysis of nasal lavage (NAL) for the upper airways, and induced sputum (IS), exhaled breath condensate (EBC) and exhaled nitric oxide (FeNO) for central and lower airways. There is strong evidence that FeNO evaluation is useful independently from subject age, while IS analysis is suitable almost for adults. Biomarker changes are generally observed upon pollutant exposure irrespective of the disease status of the participants. None of the biomarkers identified are specific for a type of pollutant exposure. Based on experimental exposure studies, there is moderate evidence that IS analysis is more sensitive than lung function tests, whereas this is not the case for biomarkers obtained by NAL or EBC. Cells and some cytokines (IL-6, IL-8 and myeloperoxidase) have been measured both in the upper respiratory tract (NAL) and in the lower airways (IS). Overall, the response to traffic exposure seems different in the two compartments. In conclusion, this survey of current literature displays the complexity of this research field, highlights the significance of short-term studies on traffic pollution and gives important tips when planning studies to detect acute respiratory effects of air pollution in a non-invasive way. © 2014 John Wiley & Sons Ltd.

  11. Noninvasive ventilation.

    PubMed

    Rabatin, J T; Gay, P C

    1999-08-01

    Noninvasive ventilation refers to the delivery of assisted ventilatory support without the use of an endotracheal tube. Noninvasive positive pressure ventilation (NPPV) can be delivered by using a volume-controlled ventilator, a pressure-controlled ventilator, a bilevel positive airway pressure ventilator, or a continuous positive airway pressure device. During the past decade, there has been a resurgence in the use of noninvasive ventilation, fueled by advances in technology and clinical trials evaluating its use. Several manufacturers produce portable devices that are simple to operate. This review describes the equipment, techniques, and complications associated with NPPV and also the indications for both short-term and long-term applications. NPPV clearly represents an important addition to the techniques available to manage patients with respiratory failure. Future clinical trials evaluating its many clinical applications will help to define populations of patients most apt to benefit from this type of treatment.

  12. Technology for noninvasive mechanical ventilation: looking into the black box

    PubMed Central

    Navajas, Daniel; Montserrat, Josep M.

    2016-01-01

    Current devices for providing noninvasive respiratory support contain sensors and built-in intelligence for automatically modifying ventilation according to the patient's needs. These devices, including automatic continuous positive airway pressure devices and noninvasive ventilators, are technologically complex and offer a considerable number of different modes of ventilation and setting options, the details of which are sometimes difficult to capture by the user. Therefore, better predicting and interpreting the actual performance of these ventilation devices in clinical application requires understanding their functioning principles and assessing their performance under well controlled bench test conditions with simulated patients. This concise review presents an updated perspective of the theoretical basis of intelligent continuous positive airway pressure and noninvasive ventilation devices, and of the tools available for assessing how these devices respond under specific ventilation phenotypes in patients requiring breathing support. PMID:27730162

  13. FIRST-line support for Assistance in Breathing in Children (FIRST-ABC): protocol for a multicentre randomised feasibility trial of non-invasive respiratory support in critically ill children.

    PubMed

    Ramnarayan, Padmanabhan; Lister, Paula; Dominguez, Troy; Habibi, Parviz; Edmonds, Naomi; Canter, Ruth; Mouncey, Paul; Peters, Mark J

    2017-06-12

    Over 18 000 children are admitted annually to UK paediatric intensive care units (PICUs), of whom nearly 75% receive respiratory support (invasive and/or non-invasive). Continuous positive airway pressure (CPAP) has traditionally been used to provide first-line non-invasive respiratory support (NRS) in PICUs; however, high-flow nasal cannula therapy (HFNC), a novel mode of NRS, has recently gained popularity despite the lack of high-quality trial evidence to support its effectiveness. This feasibility study aims to inform the design and conduct of a future definitive randomised clinical trial (RCT) comparing the two modes of respiratory support. We will conduct a three-centre randomised feasibility study over 12 months. Patients admitted to participating PICUs who satisfy eligibility criteria will be recruited to either group A (primary respiratory failure) or group B (postextubation). Consent will be obtained from parents/guardians prior to randomisation in 'planned' group B, and deferred in emergency situations (group A and 'rescue' group B). Participants will be randomised (1:1) to either CPAP or HFNC using sealed, opaque envelopes, from a computer-generated randomisation sequence with variable block sizes. The study protocol specifies algorithms for the initiation, maintenance and weaning of HFNC and CPAP. The primary outcomes are related to feasibility, including the number of eligible patients in each group, feasibility of randomising >50% of eligible patients and measures of adherence to the treatment protocols. Data will also be collected on patient outcomes (eg, mortality and length of PICU stay) to inform the selection of an appropriate outcome measure in a future RCT. We aim to recruit 120 patients to the study. Ethical approval was granted by the National Research Ethics Service Committee North East-Tyne&Wear South (15/NE/0296). Study findings will be disseminated through peer-reviewed journals, national and international conferences. NCT02612415; pre-results. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  14. FIRST-line support for Assistance in Breathing in Children (FIRST-ABC): protocol for a multicentre randomised feasibility trial of non-invasive respiratory support in critically ill children

    PubMed Central

    Ramnarayan, Padmanabhan; Lister, Paula; Dominguez, Troy; Habibi, Parviz; Edmonds, Naomi; Canter, Ruth; Mouncey, Paul; Peters, Mark J

    2017-01-01

    Introduction Over 18 000 children are admitted annually to UK paediatric intensive care units (PICUs), of whom nearly 75% receive respiratory support (invasive and/or non-invasive). Continuous positive airway pressure (CPAP) has traditionally been used to provide first-line non-invasive respiratory support (NRS) in PICUs; however, high-flow nasal cannula therapy (HFNC), a novel mode of NRS, has recently gained popularity despite the lack of high-quality trial evidence to support its effectiveness. This feasibility study aims to inform the design and conduct of a future definitive randomised clinical trial (RCT) comparing the two modes of respiratory support. Methods and analysis We will conduct a three-centre randomised feasibility study over 12 months. Patients admitted to participating PICUs who satisfy eligibility criteria will be recruited to either group A (primary respiratory failure) or group B (postextubation). Consent will be obtained from parents/guardians prior to randomisation in ‘planned’ group B, and deferred in emergency situations (group A and ‘rescue’ group B). Participants will be randomised (1:1) to either CPAP or HFNC using sealed, opaque envelopes, from a computer-generated randomisation sequence with variable block sizes. The study protocol specifies algorithms for the initiation, maintenance and weaning of HFNC and CPAP. The primary outcomes are related to feasibility, including the number of eligible patients in each group, feasibility of randomising >50% of eligible patients and measures of adherence to the treatment protocols. Data will also be collected on patient outcomes (eg, mortality and length of PICU stay) to inform the selection of an appropriate outcome measure in a future RCT. We aim to recruit 120 patients to the study. Ethics and dissemination Ethical approval was granted by the National Research Ethics Service Committee North East—Tyne&Wear South (15/NE/0296). Study findings will be disseminated through peer-reviewed journals, national and international conferences. Trials registration number NCT02612415; pre-results. PMID:28606907

  15. Clinical challenges in mechanical ventilation.

    PubMed

    Goligher, Ewan C; Ferguson, Niall D; Brochard, Laurent J

    2016-04-30

    Mechanical ventilation supports gas exchange and alleviates the work of breathing when the respiratory muscles are overwhelmed by an acute pulmonary or systemic insult. Although mechanical ventilation is not generally considered a treatment for acute respiratory failure per se, ventilator management warrants close attention because inappropriate ventilation can result in injury to the lungs or respiratory muscles and worsen morbidity and mortality. Key clinical challenges include averting intubation in patients with respiratory failure with non-invasive techniques for respiratory support; delivering lung-protective ventilation to prevent ventilator-induced lung injury; maintaining adequate gas exchange in severely hypoxaemic patients; avoiding the development of ventilator-induced diaphragm dysfunction; and diagnosing and treating the many pathophysiological mechanisms that impair liberation from mechanical ventilation. Personalisation of mechanical ventilation based on individual physiological characteristics and responses to therapy can further improve outcomes. Copyright © 2016 Elsevier Ltd. All rights reserved.

  16. Non-invasive ventilation (NIV) as an aid to rehabilitation in acute respiratory disease.

    PubMed

    Dyer, Fran; Flude, Lizzie; Bazari, Farid; Jolley, Caroline; Englebretsen, Catherine; Lai, Dilys; Polkey, Michael I; Hopkinson, Nicholas S

    2011-12-16

    Non-invasive ventilation (NIV) can increase exercise tolerance, reduce exercise induced desaturation and improve the outcome of pulmonary rehabilitation in patients with chronic respiratory disease. It is not known whether it can be applied to increase exercise capacity in patients admitted with non-hypercapnic acute exacerbations of COPD (AECOPD). We investigated the acceptability and feasibility of using NIV for this purpose. On a single occasion, patients admitted with an acute exacerbation of chronic respiratory disease who were unable to cycle for five minutes at 20 watts attempted to cycle using NIV and their endurance time (T(lim)) was recorded. To determine feasibility of this approach in clinical practice patients admitted with AECOPD were screened for participation in a trial of regular NIV assisted rehabilitation during their hospital admission. In 12 patients tested on a single occasion NIV increased T(lim) from 184(65) seconds to 331(229) seconds (p = 0.04) and patients desaturated less (median difference = 3.5%, p = 0.029). In the second study, 60 patients were admitted to hospital during a three month period of whom only 18(30)% were eligible to participate and of these patients, only four (7%) consented to participate. NIV improves exercise tolerance in patients with acute exacerbations of chronic respiratory disease but the applicability of this approach in routine clinical practice may be limited. http://www.controlled-trials.com/ISRCTN35692743.

  17. Respiratory outcomes of patients with amyotrophic lateral sclerosis: an Italian nationwide survey.

    PubMed

    Vitacca, Michele; Vianello, Andrea

    2013-09-01

    Despite recommendations, respiratory therapies remain partially underutilized in patients with amyotrophic lateral sclerosis (ALS), and different practices are described in different countries. We surveyed attitudes and practice in Italy on ALS and other neuromuscular diseases (NMDs). A questionnaire on ALS/NMD management was mailed to 178 pneumology units, which we classified into high-volume and low-volume centers according to the number of ALS/NMD patients followed in the last 5 years. Seventy-six pneumology units (43%) responded, and the responding units had 1,772 ALS patients and 1,490 NMD patients. Difficulty clearing respiratory secretions and disturbed sleep were the main reasons the ALS patients were referred to pneumology units. Vital capacity (measured in the sitting position) and arterial blood gases were measured regularly, while respiratory muscle function and cough ability were routinely assessed in over 85% of the pneumology units (mainly in high-volume centers), and 94% of pneumology units could provide noninvasive ventilation. Treatment of NMDs was similar to that of ALS, except for tracheostomy, which was less frequently performed in patients with NMDs. A multidisciplinary team approach to care was employed in approximately 90% of the responding pneumology units. Approximately a third of the units accessed palliative care services. Combined pulmonary function evaluation, long-term noninvasive ventilation, and assisted cough have become usual practices for ALS patients. Italian practices for ALS did not significantly differ from the approach to other NMDs.

  18. Time-lapse filming of newborn infants. A new technique in monitoring of behavioral states.

    PubMed

    Wallin, A

    1984-05-01

    Knowledge of the newborn infant's behavior is of great importance for an understanding of postnatal adaptation and the influence of exogenous stimuli, such as drugs. To date, however, the methods used have been to sophisticated and complex for use on a busy ward. Moreover, procedures for monitoring physiological parameters in this age group should be non-invasive and gentle for the infant, and acceptable to parents and personnel. In this paper, a simplified technique is presented where observation of the infant can be registered with an ordinary super-8 movie camera adapted to time-lapse. Heart rate, EMG and vocalization are recorded simultaneously. The time-lapse filming technique is relatively easy to learn, it is simple and economic and can be used even during routine clinical care. Assessments were made from the films only, from the recordings only and from a combination of films and recordings. All these modes of assessment were found to be satisfactorily reproducible. Filming combined with respiratory recording gives sufficient information to classify neonatal infant behavior.

  19. Effort of breathing in children receiving high-flow nasal cannula.

    PubMed

    Rubin, Sarah; Ghuman, Anoopindar; Deakers, Timothy; Khemani, Robinder; Ross, Patrick; Newth, Christopher J

    2014-01-01

    High-flow humidified nasal cannula is often used to provide noninvasive respiratory support in children. The effect of high-flow humidified nasal cannula on effort of breathing in children has not been objectively studied, and the mechanism by which respiratory support is provided remains unclear. This study uses an objective measure of effort of breathing (Pressure. Rate Product) to evaluate high-flow humidified nasal cannula in critically ill children. Prospective cohort study. Quaternary care free-standing academic children's hospital. ICU patients younger than 18 years receiving high-flow humidified nasal cannula or whom the medical team planned to extubate to high-flow humidified nasal cannula within 72 hours of enrollment. An esophageal pressure monitoring catheter was placed to measure pleural pressures via a Bicore CP-100 pulmonary mechanics monitor. Change in pleural pressure (ΔPes) and respiratory rate were measured on high-flow humidified nasal cannula at 2, 5, and 8 L/min. ΔPes and respiratory rate were multiplied to generate the Pressure.Rate Product, a well-established objective measure of effort of breathing. Baseline Pes, defined as pleural pressure at end exhalation during tidal breathing, reflected the positive pressure generated on each level of respiratory support. Twenty-five patients had measurements on high-flow humidified nasal cannula. Median age was 6.5 months (interquartile range, 1.3-15.5 mo). Median Pressure,Rate Product was lower on high-flow humidified nasal cannula 8 L/min (median, 329 cm H2O·min; interquartile range, 195-402) compared with high-flow humidified nasal cannula 5 L/min (median, 341; interquartile range, 232-475; p = 0.007) or high-flow humidified nasal cannula 2 L/min (median, 421; interquartile range, 233-621; p < 0.0001) and was lower on high-flow humidified nasal cannula 5 L/min compared with high-flow humidified nasal cannula 2 L/min (p = 0.01). Baseline Pes was higher on high-flow humidified nasal cannula 8 L/min than on high-flow humidified nasal cannula 2 L/min (p = 0.03). Increasing flow rates of high-flow humidified nasal cannula decreased effort of breathing in children, with the most significant impact seen from high-flow humidified nasal cannula 2 to 8 L/min. There are likely multiple mechanisms for this clinical effect, including generation of positive pressure and washout of airway dead space.

  20. Risk of Unsuccessful Noninvasive Ventilation for Acute Respiratory Failure in Heterogeneous Neuromuscular Diseases: A Retrospective Study.

    PubMed

    Kataoka, Hiroshi; Nanaura, Hitoki; Kinugawa, Kaoru; Uchihara, Yuto; Ohara, Hiroya; Eura, Nobuyuki; Syobatake, Ryogo; Sawa, Nobuhiro; Takao, Kiriyama; Sugie, Kazuma; Ueno, Satoshi

    2017-02-20

    If invasive ventilation can be avoided by performing noninvasive mechanical ventilation (NIV) in patients with acute respiratory failure (ARF), the disease can be effectively managed. It is important to clarify the characteristics of patients with neuromuscular diseases in whom initial NIV is likely to be unsuccessful. We studied 27 patients in stable neuromuscular condition who initially received NIV to manage fatal ARF to identify differences in factors immediately before the onset of ARF among patients who receive continuous NIV support, patients who are switched from NIV to invasive ventilation, and patients in whom NIV is discontinued. Endpoints were evaluated 24 and 72 hours after the initiation of NIV. After 24 hours, all but 1 patient with amyotrophic lateral sclerosis (ALS) received continuous NIV support. 72 hours later, 5 patients were switched from NIV to invasive ventilation, and 5 patients continued to receive NIV support. 72 hours after the initiation of NIV, the proportion of patients with a diagnosis of ALS differed significantly among the three groups (P=0.039). NIV may be attempted to manage acute fatal respiratory failure associated with neuromuscular diseases, but clinicians should carefully manage the clinical course in patients with ALS.

  1. An acoustic sensor for monitoring airflow in pediatric tracheostomy patients.

    PubMed

    Ruscher, Thomas; Wicks Phd, Alexandrina; Muelenaer Md, Andre

    2012-01-01

    Without proper monitoring, patients with artificial airways in the trachea are at high risk for complications or death. Despite routine maintenance of the tube, dislodged or copious mucus can obstruct the airway. Young children ( 3yrs) have difficulty tending to their own tubes and are particularly vulnerable to blockages. They require external respiratory sensors. In a hospital environment, ventilators, end-tidal CO2 monitors, thermistors, and other auxiliary equipment provide sufficient monitoring of respiration. However, outpatient monitoring methods, such as thoracic impedance and pulse oximetry, are indirect and prone to false positives. Desensitization of caregivers to frequent false alarms has been cited in medical literature as a contributing factor in cases of child death. Ultrasonic time-of-flight (TOF) is a technique used in specialized industrial applications to non-invasively measure liquid and gas flow. Two transducers are oriented at a diagonal across a flow channel. Velocity measurement is accomplished by detecting slight variations in transit time of contra-propagating acoustic signals with a directional component parallel to air flow. Due to the symmetry of acoustic pathway between sensors, velocity measurements are immune to partial fouling in the tube from mucus, saliva, and condensation. A first generation proof of concept prototype was constructed to evaluate the ultrasonic TOF technique for medical tracheostomy monitoring. After successful performance, a second generation prototype was designed with a smaller form factor and more advanced electronics. This prototype was tested and found to measure inspired volume with a root-mean-square error < 2% during initial trials.

  2. Sleep-Disordered Breathing in Neuromuscular Disease: Diagnostic and Therapeutic Challenges.

    PubMed

    Aboussouan, Loutfi S; Mireles-Cabodevila, Eduardo

    2017-10-01

    Normal sleep-related rapid eye movement sleep atonia, reduced lung volumes, reduced chemosensitivity, and impaired airway dilator activity become significant vulnerabilities in the setting of neuromuscular disease. In that context, the compounding effects of respiratory muscle weakness and disease-specific features that promote upper airway collapse or cause dilated cardiomyopathy contribute to various sleep-disordered breathing events. The reduction in lung volumes with neuromuscular disease is further compromised by sleep and the supine position, exaggerating the tendency for upper airway collapse and desaturation with sleep-disordered breathing events. The most commonly identified events are diaphragmatic/pseudo-central, due to a decrease in the rib cage contribution to the tidal volume during phasic rapid eye movement sleep. Obstructive and central sleep apneas are also common. Noninvasive ventilation can improve survival and quality of sleep but should be used with caution in the context of dilated cardiomyopathy or significant bulbar symptoms. Noninvasive ventilation can also trigger sleep-disordered breathing events, including ineffective triggering, autotriggering, central sleep apnea, and glottic closure, which compromise the potential benefits of the intervention by increasing arousals, reducing adherence, and impairing sleep architecture. Polysomnography plays an important diagnostic and therapeutic role by correctly categorizing sleep-disordered events, identifying sleep-disordered breathing triggered by noninvasive ventilation, and improving noninvasive ventilation settings. Optimal management may require dedicated hypoventilation protocols and a technical staff well versed in the identification and troubleshooting of respiratory events. Copyright © 2017 American College of Chest Physicians. Published by Elsevier Inc. All rights reserved.

  3. Fast Numerical Simulation of Focused Ultrasound Treatments During Respiratory Motion With Discontinuous Motion Boundaries.

    PubMed

    Schwenke, Michael; Georgii, Joachim; Preusser, Tobias

    2017-07-01

    Focused ultrasound (FUS) is rapidly gaining clinical acceptance for several target tissues in the human body. Yet, treating liver targets is not clinically applied due to a high complexity of the procedure (noninvasiveness, target motion, complex anatomy, blood cooling effects, shielding by ribs, and limited image-based monitoring). To reduce the complexity, numerical FUS simulations can be utilized for both treatment planning and execution. These use-cases demand highly accurate and computationally efficient simulations. We propose a numerical method for the simulation of abdominal FUS treatments during respiratory motion of the organs and target. Especially, a novel approach is proposed to simulate the heating during motion by solving Pennes' bioheat equation in a computational reference space, i.e., the equation is mathematically transformed to the reference. The approach allows for motion discontinuities, e.g., the sliding of the liver along the abdominal wall. Implementing the solver completely on the graphics processing unit and combining it with an atlas-based ultrasound simulation approach yields a simulation performance faster than real time (less than 50-s computing time for 100 s of treatment time) on a modern off-the-shelf laptop. The simulation method is incorporated into a treatment planning demonstration application that allows to simulate real patient cases including respiratory motion. The high performance of the presented simulation method opens the door to clinical applications. The methods bear the potential to enable the application of FUS for moving organs.

  4. Exhaled CO2 Parameters as a Tool to Assess Ventilation-Perfusion Mismatching during Neonatal Resuscitation in a Swine Model of Neonatal Asphyxia

    PubMed Central

    Li, Elliott Shang-shun; Cheung, Po-Yin; O'Reilly, Megan; LaBossiere, Joseph; Lee, Tze-Fun; Cowan, Shaun; Bigam, David L.; Schmölzer, Georg Marcus

    2016-01-01

    Background End-tidal CO2 (ETCO2), partial pressure of exhaled CO2 (PECO2), and volume of expired CO2 (VCO2) can be continuously monitored non-invasively to reflect pulmonary ventilation and perfusion status. Although ETCO2 ≥14mmHg has been shown to be associated with return of an adequate heart rate in neonatal resuscitation and quantifying the PECO2 has the potential to serve as an indicator of resuscitation quality, there is little information regarding capnometric measurement of PECO2 and ETCO2 in detecting return of spontaneous circulation (ROSC) and survivability in asphyxiated neonates receiving cardiopulmonary resuscitation (CPR). Methods Seventeen newborn piglets were anesthetized, intubated, instrumented, and exposed to 45-minute normocapnic hypoxia followed by apnea to induce asphyxia. Protocolized resuscitation was initiated when heart rate decreased to 25% of baseline. Respiratory and hemodynamic parameters including ETCO2, PECO2, VCO2, heart rate, cardiac output, and carotid artery flow were continuously measured and analyzed. Results There were no differences in respiratory and hemodynamic parameters between surviving and non-surviving piglets prior to CPR. Surviving piglets had significantly higher ETCO2, PECO2, VCO2, cardiac index, and carotid artery flow values during CPR compared to non-surviving piglets. Conclusion Surviving piglets had significantly better respiratory and hemodynamic parameters during resuscitation compared to non-surviving piglets. In addition to optimizing resuscitation efforts, capnometry can assist by predicting outcomes of newborns requiring chest compressions. PMID:26766424

  5. Weaning failure and respiratory muscle function: What has been done and what can be improved?

    PubMed

    Magalhães, Paulo A F; Camillo, Carlos A; Langer, Daniel; Andrade, Lívia B; Duarte, Maria do Carmo M B; Gosselink, Rik

    2018-01-01

    Respiratory muscle dysfunction, being a common cause of weaning failure, is strongly associated with prolonged mechanical ventilation (MV) and prolonged stay in intensive care units. Inspiratory muscle training (IMT) has been described as an important contributor to the treatment of respiratory muscle dysfunction in critically ill patients. Its effectiveness is however yet controversial. To discuss evidence for assessment of readiness and the effectiveness of interventions for liberation from MV, with special attention to the role of IMT. PubMed, LILACS, PEDro and Web of Science were searched for papers of assessment and treatment of patients who failed liberation from MV after at least one attempt published in English or Portuguese until June 2016. Weaning predictors are related to weaning success (86%-100% for sensitivity and 7%-69% for specificity) and work of breathing (73%-100% for sensitivity and 56%-100% for specificity). Spontaneous breathing trials (SBT), noninvasive MV and early mobilization have been reported to improve weaning outcomes. Two modalities of IMT were identified in five selected studies: 1) adjustment of ventilator trigger sensitivity 2) inspiratory threshold loading. Both IMT training modalities promoted significant increases in respiratory muscle strength. IMT with threshold loading showed positive effect on endurance compared to control. Methods to indentify respiratory muscle weakness in critically ill patients are feasible and described as indexes that show good accuracy. Individualized and supervised rehabilitation programs including IMT, SBT, noninvasive MV and early mobilization should be encouraged in patients with inspiratory muscle weakness. Copyright © 2017 Elsevier Ltd. All rights reserved.

  6. Assessment of continuous acoustic respiratory rate monitoring as an addition to a pulse oximetry-based patient surveillance system.

    PubMed

    McGrath, Susan P; Pyke, Joshua; Taenzer, Andreas H

    2017-06-01

    Technology advances make it possible to consider continuous acoustic respiratory rate monitoring as an integral component of physiologic surveillance systems. This study explores technical and logistical aspects of augmenting pulse oximetry-based patient surveillance systems with continuous respiratory rate monitoring and offers some insight into the impact on patient deterioration detection that may result. Acoustic respiratory rate sensors were introduced to a general care pulse oximetry-based surveillance system with respiratory rate alarms deactivated. Simulation was used after 4324 patient days to determine appropriate alarm thresholds for respiratory rate, which were then activated. Data were collected for an additional 4382 patient days. Physiologic parameters, alarm data, sensor utilization and patient/staff feedback were collected throughout the study and analyzed. No notable technical or workflow issues were observed. Sensor utilization was 57 %, with patient refusal leading reasons for nonuse (22.7 %). With respiratory rate alarm thresholds set to 6 and 40 breaths/min., the majority of nurse pager clinical notifications were triggered by low oxygen saturation values (43 %), followed by low respiratory rate values (21 %) and low pulse rate values (13 %). Mean respiratory rate collected was 16.6 ± 3.8 breaths/min. The vast majority (82 %) of low oxygen saturation states coincided with normal respiration rates of 12-20 breaths/min. Continuous respiratory rate monitoring can be successfully added to a pulse oximetry-based surveillance system without significant technical, logistical or workflow issues and is moderately well-tolerated by patients. Respiratory rate sensor alarms did not significantly impact overall system alarm burden. Respiratory rate and oxygen saturation distributions suggest adding continuous respiratory rate monitoring to a pulse oximetry-based surveillance system may not significantly improve patient deterioration detection.

  7. Characteristics and Outcome of Patients After Allogeneic Hematopoietic Stem Cell Transplantation Treated With Extracorporeal Membrane Oxygenation for Acute Respiratory Distress Syndrome.

    PubMed

    Wohlfarth, Philipp; Beutel, Gernot; Lebiedz, Pia; Stemmler, Hans-Joachim; Staudinger, Thomas; Schmidt, Matthieu; Kochanek, Matthias; Liebregts, Tobias; Taccone, Fabio Silvio; Azoulay, Elie; Demoule, Alexandre; Kluge, Stefan; Svalebjørg, Morten; Lueck, Catherina; Tischer, Johanna; Combes, Alain; Böll, Boris; Rabitsch, Werner; Schellongowski, Peter

    2017-05-01

    The acute respiratory distress syndrome is a frequent condition following allogeneic hematopoietic stem cell transplantation. Extracorporeal membrane oxygenation may serve as rescue therapy in refractory acute respiratory distress syndrome but has not been assessed in allogeneic hematopoietic stem cell transplantation recipients. Multicenter, retrospective, observational study. ICUs in 12 European tertiary care centers (Austria, Germany, France, and Belgium). All allogeneic hematopoietic stem cell transplantation recipients treated with venovenous extracorporeal membrane oxygenation for acute respiratory distress syndrome between 2010 and 2015. None. Thirty-seven patients, nine of whom underwent noninvasive ventilation at the time of extracorporeal membrane oxygenation initiation, were analyzed. ICU admission occurred at a median of 146 (interquartile range, 27-321) days after allogeneic hematopoietic stem cell transplantation. The main reason for acute respiratory distress syndrome was pneumonia in 81% of patients. All but one patient undergoing noninvasive ventilation at extracorporeal membrane oxygenation initiation had to be intubated thereafter. Overall, seven patients (19%) survived to hospital discharge and were alive and in remission of their hematologic disease after a follow-up of 18 (range, 5-30) months. Only one of 24 patients (4%) initiated on extracorporeal membrane oxygenation within 240 days after allogeneic hematopoietic stem cell transplantation survived compared to six of 13 (46%) of those treated thereafter (p < 0.01). Fourteen patients (38%) experienced bleeding events, of which six (16%) were associated with fatal outcomes. Discouraging survival rates in patients treated early after allogeneic hematopoietic stem cell transplantation do not support the use of extracorporeal membrane oxygenation for acute respiratory distress syndrome in this group. On the contrary, long-term allogeneic hematopoietic stem cell transplantation recipients otherwise eligible for full-code ICU management may be potential candidates for extracorporeal membrane oxygenation therapy in case of severe acute respiratory distress syndrome failing conventional measures.

  8. Impact of a Noninvasive Ventilation Protocol in Hospitalized Children With Acute Respiratory Failure.

    PubMed

    Jalil, Yorschua; Damiani, Felipe; Astudillo, Claudia; Villarroel, Gregory; Barañao, Patricio; Bustos, Edson; Silva, Alejandra; Mendez, Mireya

    2017-12-01

    Noninvasive ventilation (NIV) has proven to be useful in the management of children with acute respiratory failure as a result of acute lower respiratory infection. Despite this, evidence addressing the initiation and/or discontinuation criteria of NIV in children remains limited. The objective of this study was to evaluate the usefulness and clinical impact of an NIV protocol in hospitalized children with acute respiratory failure because of acute lower respiratory infection. A randomized controlled clinical trial was carried out among subjects admitted during the winter season at Hospital Josefina Martinez between May and October of 2013. Inclusion criteria were age 3 months to 2 y, diagnosis of acute lower respiratory infection and requiring NIV according to a Modified Wood Scale score of ≥ 4 points. Subjects were randomized to NIV management according to medical criteria (control group) or to protocolized management of NIV (protocol group). Hours of NIV, hospital stay, and supplemental oxygen use after discontinuation of NIV, severity changes after NIV initiation, respiratory symptoms, and proportion of intubations were considered as events of interest. A total of 23 subjects were analyzed in the control group and 24 were analyzed in the protocol group. Hours of hospital stay, NIV, and supplemental oxygen post-NIV were not significantly different between groups ( P = .70, .69, and .68, respectively). There were also no differences in intubation rate (3 of 29 for the control group and 2 of 31 for the protocol group). For the total sample there was a statistically significant decrease in the Modified Wood Scale score after 1 h of NIV ( P < .001). A similar result was observed when performing a stratified intragroup analysis. We observed that the implementation of an NIV management protocol that integrates initiation and discontinuation criteria for NIV is feasible. However, its use showed no advantages over a non-protocolized strategy. Copyright © 2017 by Daedalus Enterprises.

  9. Intermittent noninvasive ventilation after extubation in patients with chronic respiratory disorders: a multicenter randomized controlled trial (VHYPER).

    PubMed

    Vargas, Frédéric; Clavel, Marc; Sanchez-Verlan, Pascale; Garnier, Sylvain; Boyer, Alexandre; Bui, Hoang-Nam; Clouzeau, Benjamin; Sazio, Charline; Kerchache, Aissa; Guisset, Olivier; Benard, Antoine; Asselineau, Julien; Gauche, Bernard; Gruson, Didier; Silva, Stein; Vignon, Philippe; Hilbert, Gilles

    2017-11-01

    Early noninvasive ventilation (NIV) after extubation decreases the risk of respiratory failure and lowers 90-day mortality in patients with hypercapnia. Patients with chronic respiratory disease are at risk of extubation failure. Therefore, it could be useful to determine the role of NIV with a discontinuous approach, not limited to patients with hypercapnia. We assessed the efficacy of early NIV in decreasing respiratory failure after extubation in patients with chronic respiratory disorders. A prospective randomized controlled multicenter study was conducted. We enrolled 144 mechanically ventilated patients with chronic respiratory disorders who tolerated a spontaneous breathing trial. Patients were randomly allocated after extubation to receive either NIV (NIV group, n = 72), performed with a discontinuous approach, for the first 48 h, or conventional oxygen treatment (usual care group, n = 72). The primary endpoint was decreased respiratory failure within 48 h after extubation. Analysis was by intention to treat. This trial was registered with ClinicalTrials.gov (NCT01047852). Respiratory failure after extubation was less frequent in the NIV group: 6 (8.5%) versus 20 (27.8%); p = 0.0016. Six patients (8.5%) in the NIV group versus 13 (18.1%) in the usual care group were reintubated; p = 0.09. Intensive care unit (ICU) mortality and 90-day mortality did not differ significantly between the two groups (p = 0.28 and p = 0.33, respectively). Median postrandomization ICU length of stay was lower in the usual care group: 3 days (IQR 2-6) versus 4 days (IQR 2-7; p = 0.008). Patients with hypercapnia during a spontaneous breathing trial were at risk of developing postextubation respiratory failure [adjusted odds ratio (95% CI) = 4.56 (1.59-14.00); p = 0.006] and being intubated [adjusted odds ratio (95% CI) = 3.60 (1.07-13.31); p = 0.04]. Early NIV performed following a sequential protocol for the first 48 h after extubation decreased the risk of respiratory failure in patients with chronic respiratory disorders. Reintubation and mortality did not differ between NIV and conventional oxygen therapy.

  10. Evaluation of a Non-Invasive Alternative Glucose Monitor System in Patients with Diabetes Mellitus

    DTIC Science & Technology

    2008-01-07

    Diabetes Mellitus New Protocol Title: Evaluation of a Non-Invasive Alternative Glucose Monitor System in Patients with Diabetes Mellitus PRINCIPAL...Invasive Alternative Glucose Monitor System in Patients with Diabetes Mellitus 5b. GRANT NUMBER Coop Agreement # 05216002 5c. PROGRAM ELEMENT NUMBER...Flexible Medical Systems was approved by the Department of Clinical Investigation at WRAMC in January 2008. FY08 AAMTI funding will support the

  11. Motor neurone disease presenting as polycythaemia.

    PubMed

    Santana-Vaz, Natasha; Bwika, Jumaa; Morley, Kirstie; Mukherjee, Rahul

    2014-04-28

    Motor neurone disease (MND) is a chronic, progressive and currently incurable neurodegenerative disorder. This case report discusses an instance of MND presenting initially as polycythaemia, caused via insidious respiratory failure through ventilatory insufficiency. This case aims to improve clinicians' awareness of this atypical presentation and highlights the need for a high index of suspicion of respiratory failure in any patient with polycythaemia. Finally it demonstrates an improvement in quality of life associated with the use of non-invasive ventilation (NIV) in a patient with MND.

  12. Effective technologies for noninvasive remote monitoring in heart failure.

    PubMed

    Conway, Aaron; Inglis, Sally C; Clark, Robyn A

    2014-06-01

    Trials of new technologies to remotely monitor for signs and symptoms of worsening heart failure are continually emerging. The extent to which technological differences impact the effectiveness of noninvasive remote monitoring for heart failure management is unknown. This study examined the effect of specific technology used for noninvasive remote monitoring of people with heart failure on all-cause mortality and heart failure-related hospitalizations. A subanalysis of a large systematic review and meta-analysis was conducted. Studies were stratified according to the specific type of technology used, and separate meta-analyses were performed. Four different types of noninvasive remote monitoring technologies were identified, including structured telephone calls, videophone, interactive voice response devices, and telemonitoring. Only structured telephone calls and telemonitoring were effective in reducing the risk of all-cause mortality (relative risk [RR]=0.87; 95% confidence interval [CI], 0.75-1.01; p=0.06; and RR=0.62; 95% CI, 0.50-0.77; p<0.0001, respectively) and heart failure-related hospitalizations (RR=0.77; 95% CI, 0.68-0.87; p<0.001; and RR=0.75; 95% CI, 0.63-0.91; p=0.003, respectively). More research data are required for videophone and interactive voice response technologies. This subanalysis identified that only two of the four specific technologies used for noninvasive remote monitoring in heart failure improved outcomes. When results of studies that involved these disparate technologies were combined in previous meta-analyses, significant improvements in outcomes were identified. As such, this study has highlighted implications for future meta-analyses of randomized controlled trials focused on evaluating the effectiveness of remote monitoring in heart failure.

  13. Accuracy of acoustic respiration rate monitoring in pediatric patients.

    PubMed

    Patino, Mario; Redford, Daniel T; Quigley, Thomas W; Mahmoud, Mohamed; Kurth, C Dean; Szmuk, Peter

    2013-12-01

    Rainbow acoustic monitoring (RRa) utilizes acoustic technology to continuously and noninvasively determine respiratory rate from an adhesive sensor located on the neck. We sought to validate the accuracy of RRa, by comparing it to capnography, impedance pneumography, and to a reference method of counting breaths in postsurgical children. Continuous respiration rate data were recorded from RRa and capnography. In a subset of patients, intermittent respiration rate from thoracic impedance pneumography was also recorded. The reference method, counted respiratory rate by the retrospective analysis of the RRa, and capnographic waveforms while listening to recorded breath sounds were used to compare respiration rate of both capnography and RRa. Bias, precision, and limits of agreement of RRa compared with capnography and RRa and capnography compared with the reference method were calculated. Tolerance and reliability to the acoustic sensor and nasal cannula were also assessed. Thirty-nine of 40 patients (97.5%) demonstrated good tolerance of the acoustic sensor, whereas 25 of 40 patients (62.5%) demonstrated good tolerance of the nasal cannula. Intermittent thoracic impedance produced erroneous respiratory rates (>50 b·min(-1) from the other methods) on 47% of occasions. The bias ± SD and limits of agreement were -0.30 ± 3.5 b·min(-1) and -7.3 to 6.6 b·min(-1) for RRa compared with capnography; -0.1 ± 2.5 b·min(-1) and -5.0 to 5.0 b·min(-1) for RRa compared with the reference method; and 0.2 ± 3.4 b·min(-1) and -6.8 to 6.7 b·min(-1) for capnography compared with the reference method. When compared to nasal capnography, RRa showed good agreement and similar accuracy and precision but was better tolerated in postsurgical pediatric patients. © 2013 John Wiley & Sons Ltd.

  14. A wearable textile for respiratory monitoring: Feasibility assessment and analysis of sensors position on system response.

    PubMed

    Lo Presti, D; Massaroni, C; Saccomandi, P; Caponero, M A; Formica, D; Schena, E

    2017-07-01

    The interest on wearable textiles to monitor vital signs is growing in the research field and clinical scenario related to the increasing demands of long-term monitoring. Despite several smart textile-based solutions have been proposed for assessing the respiratory status, only a limited number of devices allow the respiratory monitoring in a harsh environment or in different positions of the human body. In this paper, we investigated the performances of a smart textile for respiratory rate monitoring characterized by 12 fiber optic sensors (i.e., fiber Bragg grating) placed on specific landmarks for compartmental analysis of the chest wall movements during quiet breathing. We focused on the analysis of the influence of sensor position on both peak-to-peak amplitude of sensors output and accuracy of respiratory rate measurements. This analysis was performed on two participants, who wore the textile in two positions (i.e., standing and supine). Bland-Altman analysis on respiratory rate showed promising results (better than 0.3 breaths per minute). Referring to the peak-to-peak output amplitude, the abdomen compartment showed the highest excursions in both the enrolled participants and positions. Our findings open up new approaches to design and develop smart textile for respiratory rate monitoring.

  15. Continuous noninvasive monitoring in the neonatal ICU.

    PubMed

    Sahni, Rakesh

    2017-04-01

    Standard hemodynamic monitoring such as heart rate and systemic blood pressure may only provide a crude estimation of organ perfusion during neonatal intensive care. Pulse oximetry monitoring allows for continuous noninvasive monitoring of hemoglobin oxygenation and thus provides estimation of end-organ oxygenation. This review aims to provide an overview of pulse oximetry and discuss its current and potential clinical use during neonatal intensive care. Technological advances in continuous assessment of dynamic changes in systemic oxygenation with pulse oximetry during transition to extrauterine life and beyond provide additional details about physiological interactions among the key hemodynamic factors regulating systemic blood flow distribution along with the subtle changes that are frequently transient and undetectable with standard monitoring. Noninvasive real-time continuous systemic oxygen monitoring has the potential to serve as biomarkers for early-organ dysfunction, to predict adverse short-term and long-term outcomes in critically ill neonates, and to optimize outcomes. Further studies are needed to establish values predicting adverse outcomes and to validate targeted interventions to normalize abnormal values to improve outcomes.

  16. Non-Invasive Acoustic-Based Monitoring of Heavy Water and Uranium Process Solutions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pantea, Cristian; Sinha, Dipen N.; Lakis, Rollin Evan

    2017-11-02

    The goals of the project are to leverage laboratory scientific strength in physical acoustics for critical international safeguards applications; create hardware demonstration capability for noninvasive, near real time, and low cost process monitor to capture future technology development programs; and measure physical property data to support method applicability.

  17. Novel Use of a Noninvasive Hemodynamic Monitor in a Personalized, Active Learning Simulation

    ERIC Educational Resources Information Center

    Zoller, Jonathan K.; He, Jianghua; Ballew, Angela T.; Orr, Walter N.; Flynn, Brigid C.

    2017-01-01

    The present study furthered the concept of simulation-based medical education by applying a personalized active learning component. We tested this novel approach utilizing a noninvasive hemodynamic monitor with the capability to measure and display in real time numerous hemodynamic parameters in the exercising participant. Changes in medical…

  18. Digital Signal Processing by Virtual Instrumentation of a MEMS Magnetic Field Sensor for Biomedical Applications

    PubMed Central

    Juárez-Aguirre, Raúl; Domínguez-Nicolás, Saúl M.; Manjarrez, Elías; Tapia, Jesús A.; Figueras, Eduard; Vázquez-Leal, Héctor; Aguilera-Cortés, Luz A.; Herrera-May, Agustín L.

    2013-01-01

    We present a signal processing system with virtual instrumentation of a MEMS sensor to detect magnetic flux density for biomedical applications. This system consists of a magnetic field sensor, electronic components implemented on a printed circuit board (PCB), a data acquisition (DAQ) card, and a virtual instrument. It allows the development of a semi-portable prototype with the capacity to filter small electromagnetic interference signals through digital signal processing. The virtual instrument includes an algorithm to implement different configurations of infinite impulse response (IIR) filters. The PCB contains a precision instrumentation amplifier, a demodulator, a low-pass filter (LPF) and a buffer with operational amplifier. The proposed prototype is used for real-time non-invasive monitoring of magnetic flux density in the thoracic cage of rats. The response of the rat respiratory magnetogram displays a similar behavior as the rat electromyogram (EMG). PMID:24196434

  19. Digital signal processing by virtual instrumentation of a MEMS magnetic field sensor for biomedical applications.

    PubMed

    Juárez-Aguirre, Raúl; Domínguez-Nicolás, Saúl M; Manjarrez, Elías; Tapia, Jesús A; Figueras, Eduard; Vázquez-Leal, Héctor; Aguilera-Cortés, Luz A; Herrera-May, Agustín L

    2013-11-05

    We present a signal processing system with virtual instrumentation of a MEMS sensor to detect magnetic flux density for biomedical applications. This system consists of a magnetic field sensor, electronic components implemented on a printed circuit board (PCB), a data acquisition (DAQ) card, and a virtual instrument. It allows the development of a semi-portable prototype with the capacity to filter small electromagnetic interference signals through digital signal processing. The virtual instrument includes an algorithm to implement different configurations of infinite impulse response (IIR) filters. The PCB contains a precision instrumentation amplifier, a demodulator, a low-pass filter (LPF) and a buffer with operational amplifier. The proposed prototype is used for real-time non-invasive monitoring of magnetic flux density in the thoracic cage of rats. The response of the rat respiratory magnetogram displays a similar behavior as the rat electromyogram (EMG).

  20. Trafficking receptor signatures define blood plasmablasts responding to tissue-specific immune challenge

    PubMed Central

    Seong, Yekyung; Lazarus, Nicole H.; Sutherland, Lusijah; Habtezion, Aida; Abramson, Tzvia; He, Xiao-Song; Greenberg, Harry B.

    2017-01-01

    Antibody-secreting cells are generated in regional lymphoid tissues and traffic as plasmablasts (PBs) via lymph and blood to target sites for local immunity. We used multiparameter flow cytometry to define PB trafficking programs (TPs, combinations of adhesion molecules and chemoattractant receptors) and their imprinting in patients in response to localized infection or immune insults. TPs enriched after infection or autoimmune inflammation of mucosae correlate with sites of immune response or symptoms, with different TPs imprinted during small intestinal, colon, throat, and upper respiratory immune challenge. PBs induced after intramuscular or intradermal influenza vaccination, including flu-specific antibody–secreting cells, display TPs characterized by the lack of mucosal homing receptors. PBs of healthy donors display diverse mucosa-associated TPs, consistent with homeostatic immune activity. Identification of TP signatures of PBs may facilitate noninvasive monitoring of organ-specific immune responses. PMID:28352656

  1. Non-invasive continuous blood pressure monitoring of tachycardic episodes during interventional electrophysiology.

    PubMed

    Maggi, Roberto; Viscardi, Valentina; Furukawa, Toshiyuki; Brignole, Michele

    2010-11-01

    We thought to evaluate feasibility of continuous non-invasive blood pressure monitoring during procedures of interventional electrophysiology. We evaluated continuous non-invasive finger blood pressure (BP) monitoring by means of the Nexfin device in 22 patients (mean age 70 ± 24 years), undergoing procedures of interventional electrophysiology, in critical situations of hypotension caused by tachyarrhythmias or by intermittent incremental ventricular temporary pacing till to the maximum tolerated systolic BP fall (mean 61 ± 14 mmHg per patient at a rate of 195 ± 37 bpm). In all patients, Nexfin was able to detect immediately, at the onset of tachyarrythmia, the changes in BP and recorded reliable waveforms. The quality of the signal was arbitrarily classified as excellent in 11 cases, good in 10 cases, and sufficient in 1 case. In basal conditions, calibrations of the signal occurred every 49.2 ± 24.3 s and accounted for 4% of total monitoring time; during tachyarrhythmias their frequency increased to one every 12.7 s and accounted for 19% of total recording duration. A linear correlation for a range of BP values from 41 to 190 mmHg was found between non-invasive and intra-arterial BP among a total of 1055 beats from three patients who underwent simultaneous recordings with both methods (coefficient of correlation of 0.81, P < 0.0001). In conclusion, continuous non-invasive BP monitoring is feasible in the clinical practise of an interventional electrophysiology laboratory without the need of utilization of an intra-arterial BP line.

  2. Congenital central hypoventilation syndrome: diagnostic and management challenges.

    PubMed

    Kasi, Ajay S; Perez, Iris A; Kun, Sheila S; Keens, Thomas G

    2016-01-01

    Congenital central hypoventilation syndrome (CCHS) is a rare genetic disorder with failure of central control of breathing and of the autonomic nervous system function due to a mutation in the paired-like homeobox 2B (PHOX2B) gene. Affected patients have absent or negligible ventilatory sensitivity to hypercapnia and hypoxemia, and they do not exhibit signs of respiratory distress when challenged with hypercarbia or hypoxia. The diagnosis of CCHS must be confirmed with PHOX2B gene mutation. Generally, the PHOX2B mutation genotype can aid in anticipating the severity of the phenotype. They require ventilatory support for life. Home assisted ventilation options include positive pressure ventilation via tracheostomy, noninvasive positive pressure ventilation, and diaphragm pacing via phrenic nerve stimulation, but each strategy has its associated limitations and challenges. Since all the clinical manifestations of CCHS may not manifest at birth, periodic monitoring and early intervention are necessary to prevent complications and improve outcome. Life-threatening arrhythmias can manifest at different ages and a normal cardiac monitoring study does not exclude future occurrences leading to the dilemma of timing and frequency of cardiac rhythm monitoring and treatment. Given the rare incidence of CCHS, most health care professionals are not experienced with managing CCHS patients, particularly those with diaphragm pacers. With early diagnosis and advances in home mechanical ventilation and monitoring strategies, many CCHS children are surviving into adulthood presenting new challenges in their care.

  3. Air-Flow-Driven Triboelectric Nanogenerators for Self-Powered Real-Time Respiratory Monitoring.

    PubMed

    Wang, Meng; Zhang, Jiahao; Tang, Yingjie; Li, Jun; Zhang, Baosen; Liang, Erjun; Mao, Yanchao; Wang, Xudong

    2018-06-04

    Respiration is one of the most important vital signs of humans, and respiratory monitoring plays an important role in physical health management. A low-cost and convenient real-time respiratory monitoring system is extremely desirable. In this work, we demonstrated an air-flow-driven triboelectric nanogenerator (TENG) for self-powered real-time respiratory monitoring by converting mechanical energy of human respiration into electric output signals. The operation of the TENG was based on the air-flow-driven vibration of a flexible nanostructured polytetrafluoroethylene (n-PTFE) thin film in an acrylic tube. This TENG can generate distinct real-time electric signals when exposed to the air flow from different breath behaviors. It was also found that the accumulative charge transferred in breath sensing corresponds well to the total volume of air exchanged during the respiration process. Based on this TENG device, an intelligent wireless respiratory monitoring and alert system was further developed, which used the TENG signal to directly trigger a wireless alarm or dial a cell phone to provide timely alerts in response to breath behavior changes. This research offers a promising solution for developing self-powered real-time respiratory monitoring devices.

  4. The effects of awareness and count duration on adult respiratory rate measurements: An experimental study.

    PubMed

    Hill, Andrew; Kelly, Eliza; Horswill, Mark S; Watson, Marcus O

    2018-02-01

    To investigate whether awareness of manual respiratory rate monitoring affects respiratory rate in adults, and whether count duration influences respiratory rate estimates. Nursing textbooks typically suggest that the patient should ideally be unaware of respiratory rate observations; however, there is little published evidence of the effect of awareness on respiratory rate, and none specific to manual measurement. In addition, recommendations about the length of the respiratory rate count vary from text to text, and the relevant empirical evidence is scant, inconsistent and subject to substantial methodological limitations. Experimental study with awareness of respiration monitoring (aware, unaware; randomised between-subjects) and count duration (60 s, 30 s, 15 s; within-subjects) as the independent variables. Respiratory rate (breaths/minute) was the dependent variable. Eighty-two adult volunteers were randomly assigned to aware and unaware conditions. In the baseline block, no live monitoring occurred. In the subsequent experimental block, the researcher informed aware participants that their respiratory rate would be counted, and did so. Respirations were captured throughout via video recording, and counted by blind raters viewing 60-, 30- and 15-s extracts. The data were collected in 2015. There was no baseline difference between the groups. During the experimental block, the respiratory rates of participants in the aware condition were an average of 2.13 breaths/minute lower compared to unaware participants. Reducing the count duration from 1 min to 15 s caused respiratory rate to be underestimated by an average of 2.19 breaths/minute (and 0.95 breaths/minute for 30-s counts). The awareness effect did not depend on count duration. Awareness of monitoring appears to reduce respiratory rate, and shorter monitoring durations yield systematically lower respiratory rate estimates. When interpreting and acting upon respiratory rate data, clinicians should consider the potential influence of these factors, including cumulative effects. © 2017 The Authors. Journal of Clinical Nursing Published by John Wiley & Sons Ltd.

  5. Measuring breath acetone for monitoring fat loss: Review.

    PubMed

    Anderson, Joseph C

    2015-12-01

    Endogenous acetone production is a by-product of the fat metabolism process. Because of its small size, acetone appears in exhaled breath. Historically, endogenous acetone has been measured in exhaled breath to monitor ketosis in healthy and diabetic subjects. Recently, breath acetone concentration (BrAce) has been shown to correlate with the rate of fat loss in healthy individuals. In this review, the measurement of breath acetone in healthy subjects is evaluated for its utility in predicting fat loss and its sensitivity to changes in physiologic parameters. BrAce can range from 1 ppm in healthy non-dieting subjects to 1,250 ppm in diabetic ketoacidosis. A strong correlation exists between increased BrAce and the rate of fat loss. Multiple metabolic and respiratory factors affect the measurement of BrAce. BrAce is most affected by changes in the following factors (in descending order): dietary macronutrient composition, caloric restriction, exercise, pulmonary factors, and other assorted factors that increase fat metabolism or inhibit acetone metabolism. Pulmonary factors affecting acetone exchange in the lung should be controlled to optimize the breath sample for measurement. When biologic factors are controlled, BrAce measurement provides a non-invasive tool for monitoring the rate of fat loss in healthy subjects. © 2015 The Authors Obesity published by Wiley Periodicals, Inc. on behalf of The Obesity Society (TOS).

  6. [Clinical experiences with a new reusable pressure transducer].

    PubMed

    Brandt, L; Dick, W

    1987-08-01

    Invasive blood pressure monitoring is increasing in anesthesia and intensive care. Compared to noninvasive methods, it has some decisive advantages: (1) blood pressure trends can be assessed beat by beat, which is important especially in situations of cardiac arrhythmia; (2) respiratory changes in blood pressure as one sign of hypovolemia can be detected easily; and (3) pressure changes induced by the autonomic nervous system become apparent. We studied a new, reusable pressure transducer system, the Medex Novatrans-MX800 in routine intra- and postoperative monitoring of patients undergoing cardiac surgery using the following criteria: (1) handling; (2) accuracy of measurement; (3) durability; and (4) costs. The system is easy to use and has a low susceptability to breakdown. In 29 of 31 transducers tested, the error of measurement over a range of 0-150 mmHg was less than 2% as reported by the manufacturer. Two transducers showed errors of measurement over 5% after 60 times of reuse. The mean reusability rate until the transducer became defective was 75.8 +/- 17.3 in the operating room (19 transducers tested) and 59.7 +/- 29 in the intensive care unit (12 transducers tested, 11 still in use). A comparison of costs shows that the Novatrans-MX800 system is the cheapest system for invasive pressure monitoring available at this time.

  7. Respiratory muscle function and exercise limitation in patients with chronic obstructive pulmonary disease: a review.

    PubMed

    Charususin, Noppawan; Dacha, Sauwaluk; Gosselink, Rik; Decramer, Marc; Von Leupoldt, Andreas; Reijnders, Thomas; Louvaris, Zafeiris; Langer, Daniel

    2018-01-01

    Respiratory muscle dysfunction is common and contributes to dyspnea and exercise limitation in patients with chronic obstructive pulmonary disease (COPD). Improving dynamic function of respiratory muscles during exercise might help to reduce symptoms and improve exercise capacity. Areas covered: The aims of this review are to 1) summarize physiological mechanisms linking respiratory muscle dysfunction to dyspnea and exercise limitation; 2) provide an overview of available therapeutic approaches to better maintain load-capacity balance of respiratory muscles during exercise; and 3) to summarize current knowledge on potential mechanisms explaining effects of interventions aimed at optimizing dynamic respiratory muscle function with a special focus on inspiratory muscle training. Expert commentary: Several mechanisms which are potentially linking improvements in dynamic respiratory muscle function to symptomatic and functional benefits have not been studied so far in COPD patients. Examples of underexplored areas include the study of neural processes related to the relief of acute dyspnea and the competition between respiratory and peripheral muscles for limited energy supplies during exercise. Novel methodologies are available to non-invasively study these mechanisms. Better insights into the consequences of dynamic respiratory muscle dysfunction will hopefully contribute to further refine and individualize therapeutic approaches in patients with COPD.

  8. Effect of nasal noninvasive respiratory support methods on pharyngeal provocation-induced aerodigestive reflexes in infants.

    PubMed

    Jadcherla, Sudarshan R; Hasenstab, Kathryn A; Sitaram, Swetha; Clouse, Brian J; Slaughter, Jonathan L; Shaker, Reza

    2016-06-01

    The pharynx is a locus of provocation among infants with aerodigestive morbidities manifesting as dysphagia, life-threatening events, aspiration-pneumonia, atelectasis, and reflux, and such infants often receive nasal respiratory support. We determined the impact of different oxygen delivery methods on pharyngeal stimulation-induced aerodigestive reflexes [room air (RA), nasal cannula (NC), and nasal continuous positive airway pressure (nCPAP)] while hypothesizing that the sensory motor characteristics of putative reflexes are distinct. Thirty eight infants (28.0 ± 0.7 wk gestation) underwent pharyngoesophageal manometry and respiratory inductance plethysmography to determine the effects of graded pharyngeal stimuli (n = 271) on upper and lower esophageal sphincters (UES, LES), swallowing, and deglutition-apnea. Comparisons were made between NC (n = 19), nCPAP (n = 9), and RA (n = 10) groups. Importantly, NC or nCPAP (vs. RA) had: 1) delayed feeding milestones (P < 0.05), 2) increased pharyngeal waveform recruitment and duration, greater UES nadir pressure, decreased esophageal contraction duration, decreased distal esophageal contraction amplitude, and decreased completely propagated esophageal peristalsis (all P < 0.05), and 3) similarly developed UES contractile and LES relaxation reflexes (P > 0.05). We conclude that aerodigestive reflexes were similarly developed in infants using noninvasive respiratory support with adequate upper and lower aerodigestive protection. Increased concern for GERD is unfounded in this population. These infants may benefit from targeted oromotor feeding therapies and safe pharyngeal bolus transit to accelerate feeding milestones. Copyright © 2016 the American Physiological Society.

  9. Effect of nasal noninvasive respiratory support methods on pharyngeal provocation-induced aerodigestive reflexes in infants

    PubMed Central

    Hasenstab, Kathryn A.; Sitaram, Swetha; Clouse, Brian J.; Slaughter, Jonathan L.; Shaker, Reza

    2016-01-01

    The pharynx is a locus of provocation among infants with aerodigestive morbidities manifesting as dysphagia, life-threatening events, aspiration-pneumonia, atelectasis, and reflux, and such infants often receive nasal respiratory support. We determined the impact of different oxygen delivery methods on pharyngeal stimulation-induced aerodigestive reflexes [room air (RA), nasal cannula (NC), and nasal continuous positive airway pressure (nCPAP)] while hypothesizing that the sensory motor characteristics of putative reflexes are distinct. Thirty eight infants (28.0 ± 0.7 wk gestation) underwent pharyngoesophageal manometry and respiratory inductance plethysmography to determine the effects of graded pharyngeal stimuli (n = 271) on upper and lower esophageal sphincters (UES, LES), swallowing, and deglutition-apnea. Comparisons were made between NC (n = 19), nCPAP (n = 9), and RA (n = 10) groups. Importantly, NC or nCPAP (vs. RA) had: 1) delayed feeding milestones (P < 0.05), 2) increased pharyngeal waveform recruitment and duration, greater UES nadir pressure, decreased esophageal contraction duration, decreased distal esophageal contraction amplitude, and decreased completely propagated esophageal peristalsis (all P < 0.05), and 3) similarly developed UES contractile and LES relaxation reflexes (P > 0.05). We conclude that aerodigestive reflexes were similarly developed in infants using noninvasive respiratory support with adequate upper and lower aerodigestive protection. Increased concern for GERD is unfounded in this population. These infants may benefit from targeted oromotor feeding therapies and safe pharyngeal bolus transit to accelerate feeding milestones. PMID:27012774

  10. Report on Non-invasive acoustic monitoring of D2O concentration Oct 31 2017

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pantea, Cristian; Sinha, Dipen N.; Lakis, Rollin Evan

    There is an urgent need for real-time monitoring of the hydrogen /deuterium ratio (H/D) for heavy water production monitoring. Based upon published literature, sound speed is sensitive to the deuterium content of heavy water and can be measured using existing acoustic methods to determine the deuterium concentration in heavy water solutions. We plan to adapt existing non-invasive acoustic techniques (Swept-Frequency Acoustic Interferometry and Gaussian-pulse acoustic technique) for the purpose of quantifying H/D ratios in solution. A successful demonstration will provide an easily implemented, low cost, and non-invasive method for remote and unattended H/D ratio measurements with a resolution of lessmore » than 0.2% vol.« less

  11. Respiratory Sound Analysis for Flow Estimation During Wakefulness and Sleep, and its Applications for Sleep Apnea Detection and Monitoring

    NASA Astrophysics Data System (ADS)

    Yadollahi, Azadeh

    Tracheal respiratory sounds analysis has been investigated as a non--invasive method to estimate respiratory flow and upper airway obstruction. However, the flow--sound relationship is highly variable among subjects which makes it challenging to estimate flow in general applications. Therefore, a robust model for acoustical flow estimation in a large group of individuals did not exist before. On the other hand, a major application of acoustical flow estimation is to detect flow limitations in patients with obstructive sleep apnea (OSA) during sleep. However, previously the flow--sound relationship was only investigated during wakefulness among healthy individuals. Therefore, it was necessary to examine the flow--sound relationship during sleep in OSA patients. This thesis takes the above challenges and offers innovative solutions. First, a modified linear flow--sound model was proposed to estimate respiratory flow from tracheal sounds. To remove the individual based calibration process, the statistical correlation between the model parameters and anthropometric features of 93 healthy volunteers was investigated. The results show that gender, height and smoking are the most significant factors that affect the model parameters. Hence, a general acoustical flow estimation model was proposed for people with similar height and gender. Second, flow--sound relationship during sleep and wakefulness was studied among 13 OSA patients. The results show that during sleep and wakefulness, flow--sound relation- ship follows a power law, but with different parameters. Therefore, for acoustical flow estimation during sleep, the model parameters should be extracted from sleep data to have small errors. The results confirm reliability of the acoustical flow estimation for investigating flow variations during both sleep and wakefulness. Finally, a new method for sleep apnea detection and monitoring was developed, which only requires recording the tracheal sounds and the blood's oxygen saturation level (SaO2) data. It automatically classifies the sound segments into breath, snore and noise. A weighted average of features extracted from sound segments and SaO2 signal was used to detect apnea and hypopnea events. The performance of the proposed approach was evaluated on the data of 66 patients. The results show high correlation (0.96, p < 0.0001) between the outcomes of our system and those of the polysomnography. Also, sensitivity and specificity of the proposed method in differentiating simple snorers from OSA patients were found to be more than 91%. These results are superior or comparable with the existing commercialized sleep apnea portable monitors.

  12. Physiological effects and optimisation of nasal assist-control ventilation for patients with chronic obstructive pulmonary disease in respiratory failure

    PubMed Central

    Girault, C.; Chevron, V.; Richard, J. C.; Daudenthun, I.; Pasquis, P.; Leroy, J.; Bonmarchand, G.

    1997-01-01

    BACKGROUND: A study was undertaken to investigate the effects of non- invasive assist-control ventilation (ACV) by nasal mask on respiratory physiological parameters and comfort in acute on chronic respiratory failure (ACRF). METHODS: Fifteen patients with chronic obstructive pulmonary disease (COPD) were prospectively and randomly assigned to two non-invasive ventilation (NIV) sequences in spontaneous breathing (SB) and ACV mode. ACV settings were always optimised and therefore subsequently adjusted according to patient's tolerance and air leaks. RESULTS: ACV significantly decreased all the total inspiratory work of breathing (WOBinsp) parameters, pressure time product, and oesophageal pressure variation in comparison with SB mode. The ACV mode also resulted in a significant reduction in surface diaphragmatic electromyographic activity to 36% of the control values and significantly improved the breathing pattern. SB did not change the arterial blood gas tensions from baseline values whereas ACV significantly improved both the PaO2 from a mean (SD) of 8.45 (2.95) kPa to 13.31 (2.15) kPa, PaCO2 from 9.52 (1.61) kPa to 7.39 (1.39) kPa, and the pH from 7.32 (0.03) to 7.40 (0.07). The respiratory comfort was significantly lower with ACV than with SB. CONCLUSIONS: This study shows that the clinical benefit of non-invasive ACV in the management of ACRF in patients with COPD results in a reduced inspiratory muscle activity providing an improvement in breathing pattern and gas exchange. Despite respiratory discomfort, the muscle rest provided appears sufficient when ACV settings are optimised. 


 PMID:9337827

  13. Clinical review: Long-term noninvasive ventilation

    PubMed Central

    Robert, Dominique; Argaud, Laurent

    2007-01-01

    Noninvasive positive ventilation has undergone a remarkable evolution over the past decades and is assuming an important role in the management of both acute and chronic respiratory failure. Long-term ventilatory support should be considered a standard of care to treat selected patients following an intensive care unit (ICU) stay. In this setting, appropriate use of noninvasive ventilation can be expected to improve patient outcomes, reduce ICU admission, enhance patient comfort, and increase the efficiency of health care resource utilization. Current literature indicates that noninvasive ventilation improves and stabilizes the clinical course of many patients with chronic ventilatory failure. Noninvasive ventilation also permits long-term mechanical ventilation to be an acceptable option for patients who otherwise would not have been treated if tracheostomy were the only alternative. Nevertheless, these results appear to be better in patients with neuromuscular/-parietal disorders than in chronic obstructive pulmonary disease. This clinical review will address the use of noninvasive ventilation (not including continuous positive airway pressure) mainly in diseases responsible for chronic hypoventilation (that is, restrictive disorders, including neuromuscular disease and lung disease) and incidentally in others such as obstructive sleep apnea or problems of central drive. PMID:17419882

  14. Noninvasive Ventilation in Premature Neonates.

    PubMed

    Flanagan, Keri Ann

    2016-04-01

    The use of noninvasive ventilation is a constantly evolving treatment option for respiratory disease in the premature infant. The goals of these noninvasive ventilation techniques are to improve gas exchange in the premature infant's lungs and to minimize the need for intubation and invasive mechanical ventilation. The goals of this article are to consider various uses of nasal interfaces, discuss skin care and developmental positioning concerns faced by the bedside nurse, and discuss the medical management aimed to reduce morbidity and mortality. This article explores the nursing role, the advances in medical strategies for noninvasive ventilation, and the team approach to noninvasive ventilation use in this population. Search strategy included a literature review on medical databases, such as EBSCOhost, CINAHL, PubMed, and NeoReviews. Innovative products, nursing research on developmental positioning and skin care, and advanced medical management have led to better and safer outcomes for premature infants requiring noninvasive ventilation. The medical focus of avoiding long-term mechanical ventilation would not be possible without the technology to provide noninvasive ventilation to these premature infants and the watchful eye of the nurse in terms of careful positioning, preventing skin breakdown and facial scarring, and a proper seal to maximize ventilation accuracy. This article encourages nursing-based research to quantify some of the knowledge about skin care and positioning as well as research into most appropriate uses for noninvasive ventilation devices.

  15. Respiratory Compromise as a New Paradigm for the Care of Vulnerable Hospitalized Patients.

    PubMed

    Morris, Timothy A; Gay, Peter C; MacIntyre, Neil R; Hess, Dean R; Hanneman, Sandra K; Lamberti, James P; Doherty, Dennis E; Chang, Lydia; Seckel, Maureen A

    2017-04-01

    Acute respiratory compromise describes a deterioration in respiratory function with a high likelihood of rapid progression to respiratory failure and death. Identifying patients at risk for respiratory compromise coupled with monitoring of patients who have developed respiratory compromise might allow earlier interventions to prevent or mitigate further decompensation. The National Association for the Medical Direction of Respiratory Care (NAMDRC) organized a workshop meeting with representation from many national societies to address the unmet needs of respiratory compromise from a clinical practice perspective. Respiratory compromise may arise de novo or may complicate preexisting lung disease. The group identified distinct subsets of respiratory compromise that present similar opportunities for early detection and useful intervention to prevent respiratory failure. The subtypes were characterized by the pathophysiological mechanisms they had in common: impaired control of breathing, impaired airway protection, parenchymal lung disease, increased airway resistance, hydrostatic pulmonary edema, and right-ventricular failure. Classification of acutely ill respiratory patients into one or more of these categories may help in selecting the screening and monitoring strategies that are most appropriate for the patient's particular pathophysiology. Standardized screening and monitoring practices for patients with similar mechanisms of deterioration may enhance the ability to predict respiratory failure early and prevent its occurrence. Copyright © 2017 by Daedalus Enterprises.

  16. Comparison of Comfort and Effectiveness of Total Face Mask and Oronasal Mask in Noninvasive Positive Pressure Ventilation in Patients with Acute Respiratory Failure: A Clinical Trial.

    PubMed

    Sadeghi, Somayeh; Fakharian, Atefeh; Nasri, Peiman; Kiani, Arda

    2017-01-01

    Background . There is a growing controversy about the use of oronasal masks (ONM) or total facemask (TFM) in noninvasive positive pressure ventilation (NPPV), so we designed a trial to compare the uses of these two masks in terms of effectiveness and comfort. Methods . Between February and November 2014, a total of 48 patients with respiratory failure were studied. Patients were randomized to receive NPPV via ONM or TFM. Data were recorded at 60 minutes and six and 24 hours after intervention. Patient comfort was assessed using a questionnaire. Data were analyzed using t -test and chi-square test. Repeated measures ANOVA and Mann-Whitney U test were used to compare clinical and laboratory data. Results . There were no differences in venous blood gas (VBG) values between the two groups ( P > 0.05). However, at six hours, TFM was much more effective in reducing the partial pressure of carbon dioxide (PCO2) ( P = 0.04). Patient comfort and acceptance were statistically similar in both groups ( P > 0.05). Total time of NPPV was also similar in the two groups ( P > 0.05). Conclusions . TFM was superior to ONM in acute phase of respiratory failure but not once the patients were out of acute phase.

  17. Outcomes of percutaneous endoscopic gastrostomy tube insertion in respiratory impaired amyotrophic lateral sclerosis patients under noninvasive ventilation.

    PubMed

    Czell, David; Bauer, Matthias; Binek, Janek; Schoch, Otto D; Weber, Markus

    2013-05-01

    Percutaneous endoscopic gastrostomy (PEG) tube placement in amyotrophic lateral sclerosis (ALS) patients with impaired respiratory function is associated with an increased risk of peri-procedural and post-interventional complications. It was the aim of the study to analyze peri- and post-interventional complications and survival after PEG tube placement under noninvasive ventilation (NIV) in ALS patients with various degrees of respiratory impairment. Twenty-six subjects were included in this retrospective case study. Prior to PEG tube placement, training with ventilatory support via an oronasal mask was performed with ALS subjects on the pneumology ward. PEG placement was then performed under continuous NIV. FVC, sniff nasal inspiratory pressure, and demographic data were assessed. Complication rates and 1-month and overall survival rates were analyzed. There were no deaths within 24 hours after PEG placement. One subject died within the first month. The mean survival rate after PEG was 12 ± 10 months (range 0.6-42 months). There was no difference in post-PEG survival between subjects with moderately (> 50%) and severely (< 50%) impaired FVC. In this case series, PEG tube insertion was associated with minimal peri- and post-procedural complications. The low complication rate might be due to the systematic use of procedural NIV in ALS subjects.

  18. Diagnosis and Anti-Reflux Therapy for GERD with Respiratory Symptoms: A Study Using Multichannel Intraluminal Impedance-pH Monitoring

    PubMed Central

    Zhang, Chao; Wu, Jimin; Hu, Zhiwei; Yan, Chao; Gao, Xiang; Liang, Weitao; Liu, Diangang; Li, Fei; Wang, Zhonggao

    2016-01-01

    Background/Aims Respiratory symptoms are often associated with gastroesophageal reflux disease (GERD). Although the role of multichannel intraluminal impedance–pH (MII-pH) monitoring in GERD is clear, little is known regarding the characteristics of patients with respiratory symptoms based on MII-pH monitoring and anti-reflux therapy. We evaluated a cohort of GERD patients to identify the MII-pH parameters of GERD-related respiratory symptoms and to assess the anti-reflux therapy outcomes. Methods We undertook a prospective study of patients who were referred for GERD evaluation from January 2011 to January 2012. One hundred ninety-five patients underwent MII-pH monitoring and esophageal manometry, and one hundred sixty-five patients underwent invasive anti-reflux therapy that included laparoscopic Toupet fundoplication (LTF) and the Stretta procedure. The patient characteristics and MII-pH parameters were analyzed, and the symptom scores were assessed at baseline and at 1- and 3-year follow-up evaluations. Results Of the 195 patients, 96 (49.2%) exhibited respiratory symptoms and significantly more reflux episodes (70.7±29.3) than patients without respiratory symptoms (64.7±24.4, p = 0.044) based on the MII-pH monitoring results. Moreover, the group of patients with respiratory symptoms exhibited more proximal reflux episodes (35.2±21.3) than the non-respiratory symptomatic group (28.3±17.9, p = 0.013). One hundred twenty-five patients following the Stretta procedure (n = 60, 31 with respiratory symptoms) or LTF (n = 65, 35 with respiratory symptoms) completed the designated 3-year follow-up period and were included in the final analysis. The symptom scores after anti-reflux therapy all decreased relative to the corresponding baseline values (p<0.05), and there were no significant differences in the control of respiration between the Stretta procedure and LTF (p>0.05). However, LTF significantly reduced the recurrence (re-operation) rate compared with the Stretta procedure (0 vs. 19.4%, p = 0.006). Conclusions MII-pH monitoring effectively detected respiratory-related predictive parameters, including total/proximal reflux episodes and symptom correlations. We found that GERD patients with respiratory symptoms exhibited more proximal and total reflux episodes but not more acid-related episodes, as determined by MII-pH monitoring. Thus, such monitoring could be useful for diagnosing atypical GERD patients with respiratory symptoms. Furthermore, LTF exhibited a more significant effect on controlling typical symptoms in all GERD patients and reducing the recurrence rate than the Stretta procedure in patients with respiratory symptoms. PMID:27532103

  19. Non-invasive continuous blood pressure monitoring of tachycardic episodes during interventional electrophysiology

    PubMed Central

    Maggi, Roberto; Viscardi, Valentina; Furukawa, Toshiyuki; Brignole, Michele

    2010-01-01

    Aims We thought to evaluate feasibility of continuous non-invasive blood pressure monitoring during procedures of interventional electrophysiology. Methods and results We evaluated continuous non-invasive finger blood pressure (BP) monitoring by means of the Nexfin device in 22 patients (mean age 70 ± 24 years), undergoing procedures of interventional electrophysiology, in critical situations of hypotension caused by tachyarrhythmias or by intermittent incremental ventricular temporary pacing till to the maximum tolerated systolic BP fall (mean 61 ± 14 mmHg per patient at a rate of 195 ± 37 bpm). In all patients, Nexfin was able to detect immediately, at the onset of tachyarrythmia, the changes in BP and recorded reliable waveforms. The quality of the signal was arbitrarily classified as excellent in 11 cases, good in 10 cases, and sufficient in 1 case. In basal conditions, calibrations of the signal occurred every 49.2 ± 24.3 s and accounted for 4% of total monitoring time; during tachyarrhythmias their frequency increased to one every 12.7 s and accounted for 19% of total recording duration. A linear correlation for a range of BP values from 41 to 190 mmHg was found between non-invasive and intra-arterial BP among a total of 1055 beats from three patients who underwent simultaneous recordings with both methods (coefficient of correlation of 0.81, P < 0.0001). Conclusion In conclusion, continuous non-invasive BP monitoring is feasible in the clinical practise of an interventional electrophysiology laboratory without the need of utilization of an intra-arterial BP line. PMID:20837572

  20. Noninvasive determination of respiratory ozone absorption: development of a fast-responding ozone analyzer.

    PubMed

    Ultman, J S; Ben-Jebria, A

    1991-03-01

    We developed a chemiluminescent ozone analyzer and constructed an ozone bolus generator with the eventual goal of using a bolus-response method to measure noninvasively the longitudinal distribution of ozone absorption in human lungs. Because the analyzer will be used to sample gases within a single breath, it must have a sufficiently rapid response to monitor changes in ozone concentration during a four-second breathing period, yet its sampling flow must be small enough that it does not interfere with quiet respiratory flows of 300 mL/sec. Our analyzer, which is based on the chemiluminescent reaction between 2-methyl-2-butene and ozone, has favorable performance characteristics: a 90 percent step-response time of 110 msec; a linear calibration from 0.03 to 10 parts per million (ppm)2 with a sensitivity of 2.3 nA/ppm; a signal-to-noise ratio of 30 evaluated at 0.5 ppm; and a minimum detection limit of 0.017 ppm. At an airflow corresponding to quiet breathing, the ozone generator is capable of producing single boluses with a peak ozone fraction as high as 4 ppm, but containing only 0.35 micrograms of ozone dispersed over a small volume of 19 mL. To test the combination of ozone analyzer and bolus generator, we performed bolus-response experiments at steady airflows of 50 to 200 mL/sec in excised pig and sheep tracheas. In spite of the small surface area available for radial diffusion, we found that 25 to 50 percent of the ozone introduced into the trachea was absorbed. By comparing the mathematical moments of the bolus input and the response curves to the predictions of a diffusion theory, we computed an absorption coefficient (K). The values of K increased with increasing airflow, implying that ozone absorption is limited by diffusion processes in the airway lumen as well as in the surrounding tissue.

  1. High pressure versus high intensity noninvasive ventilation in stable hypercapnic chronic obstructive pulmonary disease: a randomized crossover trial.

    PubMed

    Murphy, Patrick B; Brignall, Kate; Moxham, John; Polkey, Michael I; Davidson, A Craig; Hart, Nicholas

    2012-01-01

    High-intensity (high-pressure and high backup rate) noninvasive ventilation has recently been advocated for the management of stable hypercapnic chronic obstructive pulmonary disease (COPD). However, the relative contributions of high inspiratory pressure and high backup rate to ventilator adherence and physiological outcome have not been investigated. Patients with stable hypercapnic COPD (daytime PaCO(2) > 6 kPa) and nocturnal hypoventilation were enrolled. Patients were randomly allocated to high-pressure and high backup rate (high-intensity) and high-pressure and low backup rate (high-pressure) for a 6-week period. At the end of the first treatment period, patients were switched to the alternative treatment. The primary outcome measure was mean nightly ventilator usage. Twelve patients were recruited, with seven completing the 12-week trial protocol. The mean patient age was 71 ± 8 years, with a forced expiratory volume in one second (FEV(1))/forced vital capacity (FVC) of 50% ± 13% and FEV(1) of 32% ± 12%. The baseline PaCO(2) and PaO(2) were 8.6 ± 1.7 kPa and 7.3 ± 1.4 kPa, respectively. There was no significant difference demonstrated in mean nightly ventilator usage between the high-intensity and high-pressure groups (difference of 4 minutes; 95% confidence interval -45 to 53; P = 0.9). Furthermore, there were no differences in any of the secondary endpoints, with the exception of the respiratory domain of the Severe Respiratory Insufficiency questionnaire, which was lower in the high-intensity arm than in the high-pressure arm (57 ± 11 versus 69 ± 16; P < 0.05). There was no additional benefit, in terms of night-time ventilator adherence or any of the other measured parameters, demonstrated by addition of a high backup rate to high-pressure noninvasive ventilation. These data suggest that it is the high-pressure component of the high-intensity noninvasive ventilation approach that plays the important therapeutic role in the management of hypercapnic respiratory failure in COPD patients.

  2. Non-invasive diagnostic platforms in management of non-small cell lung cancer: opportunities and challenges

    PubMed Central

    Pennell, Nathan A.

    2017-01-01

    Several non-invasive diagnostic platforms are already being incorporated in routine clinical practice in the work up and monitoring of patients with lung cancer. These approaches have great potential to improve patient selection and monitor patients while on therapy, however several challenges exist in clinical validation and standardization of such platforms. In this review, we summarize the current technologies available for non-invasive diagnostic evaluation from the blood of patients with non-small cell lung cancer (NSCLC), and discuss the technical and logistical challenges associated incorporating such testing in clinical practice. PMID:29057238

  3. Preferential macrophage recruitment and polarization in LPS-induced animal model for COPD: noninvasive tracking using MRI.

    PubMed

    Al Faraj, Achraf; Sultana Shaik, Asma; Pureza, Mary Angeline; Alnafea, Mohammad; Halwani, Rabih

    2014-01-01

    Noninvasive imaging of macrophages activity has raised increasing interest for diagnosis of chronic obstructive respiratory diseases (COPD), which make them attractive vehicles to deliver contrast agents for diagnostic or drugs for therapeutic purposes. This study was designed to monitor and evaluate the migration of differently polarized M1 and M2 iron labeled macrophage subsets to the lung of a LPS-induced COPD animal model and to assess their polarization state once they have reached the inflammatory sites in the lung after intravenous injection. Ex vivo polarized bone marrow derived M1 or M2 macrophages were first efficiently and safely labeled with amine-modified PEGylated dextran-coated SPIO nanoparticles and without altering their polarization profile. Their biodistribution in abdominal organs and their homing to the site of inflammation in the lung was tracked for the first time using a free-breathing non-invasive MR imaging protocol on a 4.7T magnet after their intravenous administration. This imaging protocol was optimized to allow both detection of iron labeled macrophages and visualization of inflammation in the lung. M1 and M2 macrophages were successfully detected in the lung starting from 2 hours post injection with no variation in their migration profile. Quantification of cytokines release, analysis of surface membrane expression using flow cytometry and immunohistochemistry investigations confirmed the successful recruitment of injected iron labeled macrophages in the lung of COPD mice and revealed that even with a continuum switch in the polarization profile of M1 and M2 macrophages during the time course of inflammation a balanced number of macrophage subsets predominate.

  4. The Multicenter Aerobic Iron Respiratory Chain of Acidithiobacillus ferrooxidans Functions as an Ensemble with a Single Macroscopic Rate Constant

    DOE PAGES

    Li, Ting-Feng; Painter, Richard G.; Ban, Bhupal; ...

    2015-06-03

    Electron transfer reactions among three prominent colored proteins in intact cells of Acidithiobacillus ferrooxidans were monitored using an integrating cavity absorption meter that permitted the acquisition of accurate absorbance data in suspensions of cells that scattered light. The concentrations of proteins in the periplasmic space were estimated to be 350 and 25 mg/ml for rusticyanin and cytochrome c, respectively; cytochrome a was present as one molecule for every 91 nm2 in the cytoplasmic membrane. All three proteins were rapidly reduced to the same relative extent when suspensions of live bacteria were mixed with different concentrations of ferrous ions at pHmore » 1.5. The subsequent molecular oxygen-dependent oxidation of the multicenter respiratory chain occurred with a single macroscopic rate constant, regardless of the proteins' in vitro redox potentials or their putative positions in the aerobic iron respiratory chain. The crowded electron transport proteins in the periplasm of the organism constituted an electron conductive medium where the network of protein interactions functioned in a concerted fashion as a single ensemble with a standard reduction potential of 650 mV. The appearance of product ferric ions was correlated with the reduction levels of the periplasmic electron transfer proteins; the limiting first-order catalytic rate constant for aerobic respiration on iron was 7,400 s -1. The ability to conduct direct spectrophotometric studies under noninvasive physiological conditions represents a new and powerful approach to examine the extent and rates of biological events in situ without disrupting the complexity of the live cellular environment.« less

  5. [Non-invasive mechanical ventilation in the pre- and intraoperative period and difficult airway].

    PubMed

    Esquinas, A M; Jover, J L; Úbeda, A; Belda, F J

    2015-11-01

    Non-invasive mechanical ventilation is a method of ventilatory assistance aimed at increasing alveolar ventilation, thus achieving, in selected subjects, the avoidance of endotracheal intubation and invasive mechanical ventilation, with the consequent improvement in survival. There has been a systematic review and study of the technical, clinical experiences, and recommendations concerning the application of non-invasive mechanical ventilation in the pre- and intraoperative period. The use of prophylactic non-invasive mechanical ventilation before surgery that involves significant alterations in the ventilatory function may decrease the incidence of postoperative respiratory complications. Its intraoperative use will mainly depend on the type of surgery, type of anaesthetic technique, and the clinical status of the patient. Its use allows greater anaesthetic depth without deterioration of oxygenation and ventilation of patients. Copyright © 2015 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Publicado por Elsevier España, S.L.U. All rights reserved.

  6. Epidemiology of NIV for Acute Respiratory Failure in COPD Patients: Results from the International Surveys vs. the "Real World".

    PubMed

    Ozsancak Ugurlu, Aylin; Habesoglu, Mehmet Ali

    2017-08-01

    Non-invasive ventilation (NIV) has been recommended as the  first-line ventilation modality for acute respiratory failure (ARF) due to acute exacerbation of chronic obstructive pulmonary disease (AECOPD) based on strong evidence. However, everyday clinical practice may differ from findings of multiple randomized controlled trials. Physicians and respiratory therapists involved in NIV management have been queried about its utilization and effectiveness. In addition to these estimates, cohort studies and analysis of large inpatient dataset of patients with AECOPD and ARF managed with NIV have been extensively published over the last two decades. This review summarizes the perception of medical staff vs. the "real life" data about NIV use for ARF in AECOPD patients.

  7. Respiratory distress in term neonates in low-resource settings.

    PubMed

    Sivanandan, Sindhu; Agarwal, Ramesh; Sethi, Amanpreet

    2017-08-01

    Most neonatal deaths worldwide occur in low- and middle-income countries (LMICs). Respiratory distress is an important cause of neonatal morbidity and mortality. The epidemiology of respiratory distress among term neonates who constitute the vast majority of births is under reported. The scarcely available data from LMICs suggest an incidence of 1.2% to 7.2% among term live births and greater morbidity compared to that in high-income countries. Pneumonia and meconium aspiration syndrome are the predominant causes among outborn neonates, but next only to transient tachypnea among inborn neonates. Community management of neonatal sepsis/pneumonia using simplified antibiotic regimens when referral is not feasible, implementation of non-invasive ventilation, and innovative low-cost technologies to deliver respiratory therapy are important advances that have taken place in these settings. There is an urgent need to generate data on respiratory morbidities among term neonates so that the limited resources in these settings can be allocated judiciously. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. Wild cats of the Sky Islands: a summary of monitoring efforts using noninvasive techniques

    Treesearch

    Lisa Haynes; Zoe Hackl; Melanie Culver

    2005-01-01

    A variety of efforts are taking place to detect, inventory, and monitor the wild felids (pumas, bobcats, jaguars, and ocelots) of the Madrean Archipelago. Researchers are using a suite of noninvasive methods, including infrared-triggered photography, DNA analysis of scat and hair (collected from “hair snares”), and old-fashioned tracking and sign searches. These...

  9. Borderline Personality Disorder and Emotion Regulation: Insights from the Polyvagal Theory

    ERIC Educational Resources Information Center

    Austin, Marilyn A.; Riniolo, Todd C.; Porges, Stephen W.

    2007-01-01

    The current study provides the first published evidence that the parasympathetic component of the autonomic nervous system differentiates the response profiles between individuals diagnosed with borderline personality disorder (BPD) and controls. Respiratory sinus arrhythmia (RSA), a non-invasive marker of the influence of the myelinated vagal…

  10. Respiratory insufficiency with preserved diaphragmatic function in amyotrophic lateral sclerosis.

    PubMed

    Yamauchi, Rika; Imai, Tomihiro; Tsuda, Emiko; Hozuki, Takayoshi; Yamamoto, Daisuke; Shimohama, Shun

    2014-01-01

    We performed a longitudinal study to elucidate the correlation between respiratory insufficiency and respiratory biomarkers, including diaphragmatic compound muscle action potential (DCMAP), at the initiation of noninvasive ventilation (NIV) in patients with amyotrophic lateral sclerosis (ALS). The patients were assessed at least every six months. Additional assessments were performed at the start of respiratory therapy when the patients met the criteria for the initiation of NIV. Each assessment consisted of a full neurological examination, a phrenic nerve conduction study, respiratory function tests, and nocturnal pulsed oximetry. We enrolled 43 patients with either definite or probable ALS as defined by the revised El Escorial criteria. The patients were divided into two groups according to the timing of the initiation of respiratory therapy. Seventeen patients (group A) met the criteria for NIV initiation when their DCMAP remained normal. Twenty-six patients (group B) met the criteria when their DCMAP decreased below normal limits. Although respiratory function parameters were significantly worse in group B compared with group A at NIV initiation, more than 80% of the patients in both groups developed nocturnal desaturation during sleep. DCMAP is not always a reliable indicator for determining the optimal timing for NIV initiation during the progression of respiratory insufficiency in ALS. Physicians should be aware of the risk of respiratory insufficiency during sleep in patients with ALS.

  11. Accurate discrimination of the wake-sleep states of mice using non-invasive whole-body plethysmography.

    PubMed

    Bastianini, Stefano; Alvente, Sara; Berteotti, Chiara; Lo Martire, Viviana; Silvani, Alessandro; Swoap, Steven J; Valli, Alice; Zoccoli, Giovanna; Cohen, Gary

    2017-01-31

    A major limitation in the study of sleep breathing disorders in mouse models of pathology is the need to combine whole-body plethysmography (WBP) to measure respiration with electroencephalography/electromyography (EEG/EMG) to discriminate wake-sleep states. However, murine wake-sleep states may be discriminated from breathing and body movements registered by the WBP signal alone. Our goal was to compare the EEG/EMG-based and the WBP-based scoring of wake-sleep states of mice, and provide formal guidelines for the latter. EEG, EMG, blood pressure and WBP signals were simultaneously recorded from 20 mice. Wake-sleep states were scored based either on EEG/EMG or on WBP signals and sleep-dependent respiratory and cardiovascular estimates were calculated. We found that the overall agreement between the 2 methods was 90%, with a high Cohen's Kappa index (0.82). The inter-rater agreement between 2 experts and between 1 expert and 1 naïve sleep investigators gave similar results. Sleep-dependent respiratory and cardiovascular estimates did not depend on the scoring method. We show that non-invasive discrimination of the wake-sleep states of mice based on visual inspection of the WBP signal is accurate, reliable and reproducible. This work may set the stage for non-invasive high-throughput experiments evaluating sleep and breathing patterns on mouse models of pathophysiology.

  12. Can patients with moderate to severe acute respiratory failure from COPD be treated safely with noninvasive mechanical ventilation on the ward?

    PubMed

    Yalcinsoy, Murat; Salturk, Cuneyt; Oztas, Selahattin; Gungor, Sinem; Ozmen, Ipek; Kabadayi, Feyyaz; Oztim, Aysem Askim; Aksoy, Emine; Adıguzel, Nalan; Oruc, Ozlem; Karakurt, Zuhal

    2016-01-01

    Noninvasive mechanical ventilation (NIMV) usage outside of intensive care unit is not recommended in patients with COPD for severe acute respiratory failure (ARF). We assessed the factors associated with failure of NIMV in patients with ARF and severe acidosis admitted to the emergency department and followed on respiratory ward. This is a retrospective observational cohort study conducted in a tertiary teaching hospital specialized in chest diseases and thoracic surgery between June 1, 2013 and May 31, 2014. COPD patients who were admitted to our emergency department due to ARF were included. Patients were grouped according to the severity of acidosis into two groups: group 1 (pH=7.20-7.25) and group 2 (pH=7.26-7.30). Group 1 included 59 patients (mean age: 70±10 years, 30.5% female) and group 2 included 171 patients (mean age: 67±11 years, 28.7% female). On multivariable analysis, partial arterial oxygen pressure to the inspired fractionated oxygen (PaO2/FiO2) ratio <200, delta pH value <0.30, and pH value <7.31 on control arterial blood gas after NIMV in the emergency room and peak C-reactive protein were found to be the risk factors for NIMV failure in COPD patients with ARF in the ward. NIMV is effective not only in mild respiratory failure but also with severe forms of COPD patients presenting with severe exacerbation. The determination of the failure criteria of NIMV and the expertise of the team is critical for treatment success.

  13. Variations in respiratory sounds in relation to fluid accumulation in the upper airways.

    PubMed

    Yadollahi, Azadeh; Rudzicz, Frank; Montazeri, Aman; Bradley, T Douglas

    2013-01-01

    Obstructive sleep apnea (OSA) is a common disorder due to recurrent collapse of the upper airway (UA) during sleep that increases the risk for several cardiovascular diseases. Recently, we showed that nocturnal fluid accumulation in the neck can narrow the UA and predispose to OSA. Our goal is to develop non-invasive methods to study the pathogenesis of OSA and the factors that increase the risks of developing it. Respiratory sound analysis is a simple and non-invasive way to study variations in the properties of the UA. In this study we examine whether such analysis can be used to estimate the amount of neck fluid volume and whether fluid accumulation in the neck alters the properties of these sounds. Our acoustic features include estimates of formants, pitch, energy, duration, zero crossing rate, average power, Mel frequency power, Mel cepstral coefficients, skewness, and kurtosis across segments of sleep. Our results show that while all acoustic features vary significantly among subjects, only the variations in respiratory sound energy, power, duration, pitch, and formants varied significantly over time. Decreases in energy and power over time accompany increases in neck fluid volume which may indicate narrowing of UA and consequently an increased risk of OSA. Finally, simple discriminant analysis was used to estimate broad classes of neck fluid volume from acoustic features with an accuracy of 75%. These results suggest that acoustic analysis of respiratory sounds might be used to assess the role of fluid accumulation in the neck on the pathogenesis of OSA.

  14. Optical monitoring of spinal cord hemodynamics, a feasibility study

    NASA Astrophysics Data System (ADS)

    Shadgan, Babak; Kwon, Brian K.; Streijger, Femke; Manouchehri, Neda; So, Kitty; Shortt, Katelyn; Cripton, Peter A.; Macnab, Andrew

    2017-02-01

    Background: After an acute traumatic spinal cord injury (SCI), the spinal cord is subjected to ischemia, hypoxia, and increased hydrostatic pressure which exacerbate further secondary damage and neuronal deficit. The purpose of this pilot study was to explore the use of near infrared spectroscopy (NIRS) for non-invasive and real-time monitoring of these changes within the injured spinal cord in an animal model. NIRS is a non-invasive optical technique that utilizes light in the near infrared spectrum to monitor changes in the concentration of tissue chromophores from which alterations in tissues oxygenation and perfusion can be inferred in real time. Methods: A custom-made miniaturized NIRS sensor was developed to monitor spinal cord hemodynamics and oxygenation noninvasively and in real time simultaneously with invasive, intraparenchymal monitoring in a pig model of SCI. The spinal cord around the T10 injury site was instrumented with intraparenchymal probes inserted directly into the spinal cord to measure oxygen pressure, blood flow, and hydrostatic pressure, and the same region of the spinal cord was monitored with the custom-designed extradural NIRS probe. We investigated how well the extradural NIRS probe detected intraparenchymal changes adjacent to the injury site after alterations in systemic blood pressure, global hypoxia, and traumatic injury generated by a weight-drop contusion. Results: The NIRS sensor successfully identified periods of systemic hypoxia, re-ventilation and changes in spinal cord perfusion and oxygenation during alterations of mean arterial pressure and following spinal cord injury. Conclusion: This pilot study indicates that extradural NIRS monitoring of the spinal cord is feasible as a non-invasive optical method to identify changes in spinal cord hemodynamics and oxygenation in real time. Further development of this technique would allow clinicians to monitor real-time physiologic changes within the injured spinal cord during the acute post-injury period.

  15. [Monitorization of respiratory mechanics in the ventilated patient].

    PubMed

    García-Prieto, E; Amado-Rodríguez, L; Albaiceta, G M

    2014-01-01

    Monitoring during mechanical ventilation allows the measurement of different parameters of respiratory mechanics. Accurate interpretation of these data can be useful for characterizing the situation of the different components of the respiratory system, and for guiding ventilator settings. In this review, we describe the basic concepts of respiratory mechanics, their interpretation, and their potential use in fine-tuning mechanical ventilation. Copyright © 2013 Elsevier España, S.L. y SEMICYUC. All rights reserved.

  16. [Respiratory treatments in neuromuscular disease].

    PubMed

    Martínez Carrasco, C; Cols Roig, M; Salcedo Posadas, A; Sardon Prado, O; Asensio de la Cruz, O; Torrent Vernetta, A

    2014-10-01

    In a previous article, a review was presented of the respiratory pathophysiology of the patient with neuromuscular disease, as well as their clinical evaluation and the major complications causing pulmonary deterioration. This article presents the respiratory treatments required to preserve lung function in neuromuscular disease as long as possible, as well as in special situations (respiratory infections, spinal curvature surgery, etc.). Special emphasis is made on the use of non-invasive ventilation, which is changing the natural history of many of these diseases. The increase in survival and life expectancy of these children means that they can continue their clinical care in adult units. The transition from pediatric care must be an active, timely and progressive process. It may be slightly stressful for the patient before the adaptation to this new environment, with multidisciplinary care always being maintained. Copyright © 2013 Asociación Española de Pediatría. Published by Elsevier Espana. All rights reserved.

  17. [Clinical guidelines for diagnosis, treatment and monitoring of patients with non-invasive breast cancer].

    PubMed

    Brnijć, Zoran; Brkljacić, Boris; Drinković, Ivan; Jakić-Razumović, Jasminka; Kardum-Skelin, Ika; Krajina, Zdenko; Margaritoni, Marko; Strnad, Marija; Sarcević, Bozena; Tomić, Snjezana; Zic, Rado

    2012-01-01

    Breast cancer is the most common malignancy in women. Early diagnosis and more effective treatment of invasive breast cancer resulted in significant mortality reduction, improvement of survival and the quality of life of the patients. The management od non-invasive breast cancer, on the contrary, is still controversial and the problem of overdiagnosis and overtreatment of patients come to evidence. In the following text a multidisciplinary team of experts brings the first consensus guidelines aimed to standardize and optimize the criteria and management in diagnosis, treatment and monitoring of non-invasive breast cancer patients in the Republic of Croatia.

  18. Computerized respiratory sounds: a comparison between patients with stable and exacerbated COPD.

    PubMed

    Jácome, Cristina; Oliveira, Ana; Marques, Alda

    2017-09-01

    Diagnosis of acute exacerbations of chronic obstructive pulmonary disease (AECOPD) is often challenging as it relies on patients' clinical presentation. Computerized respiratory sounds (CRS), namely crackles and wheezes, may have the potential to contribute for the objective diagnosis/monitoring of an AECOPD. This study explored if CRS differ during stable and exacerbation periods in patients with COPD. 13 patients with stable COPD and 14 with AECOPD were enrolled. CRS were recorded simultaneously at trachea, anterior, lateral and posterior chest locations using seven stethoscopes. Airflow (0.4-0.6l/s) was recorded with a pneumotachograph. Breathing phases were detected using airflow signals; crackles and wheezes with validated algorithms. At trachea, anterior and lateral chest, no significant differences were found between the two groups in the number of inspiratory/expiratory crackles or inspiratory wheeze occupation rate. At posterior chest, the number of crackles (median 2.97-3.17 vs. 0.83-1.2, P < 0.001) and wheeze occupation rate (median 3.28%-3.8% vs. 1.12%-1.77%, P = 0.014-0.016) during both inspiration and expiration were significantly higher in patients with AECOPD than in stable patients. During expiration, wheeze occupation rate was also significantly higher in patients with AECOPD at trachea (median 3.12% vs. 0.79%, P < 0.001) and anterior chest (median 3.55% vs. 1.28%, P < 0.001). Crackles and wheezes are more frequent in patients with AECOPD than in stable patients, particularly at posterior chest. These findings suggest that these CRS can contribute to the objective diagnosis/monitoring of AECOPD, which is especially valuable considering that they can be obtained by integrating computerized techniques with pulmonary auscultation, a noninvasive method that is a component of patients' physical examination. © 2015 John Wiley & Sons Ltd.

  19. Noninvasive Diagnostic Devices for Diabetes through Measuring Tear Glucose

    PubMed Central

    Zhang, Jin; Hodge, William; Hutnick, Cindy; Wang, Xianbin

    2011-01-01

    This article reviews the development of a noninvasive diagnostic for diabetes by detecting ocular glucose. Early diagnosis and daily management are very important to diabetes patients to ensure a healthy life. Commercial blood glucose sensors have been used since the 1970s. Millions of diabetes patients have to prick their finger for a drop of blood 4–5 times a day to check blood glucose levels—almost 1800 times annually. There is a strong need to have a noninvasive device to help patients to manage the disease easily and painlessly. Instead of detecting the glucose in blood, monitoring the glucose level in other body fluids may provide a feasible approach for noninvasive diagnosis and diabetes control. Tear glucose has been studied for several decades. This article reviews studies on ocular glucose and its monitoring methods. Attempts to continuously monitor the concentration of tear glucose by using contact lens-based sensors are discussed as well as our current development of a nanostructured lens-based sensor for diabetes. This disposable biosensor for the detection of tear glucose may provide an alternative method to help patients manage the disease conveniently. PMID:21303640

  20. Noninvasive monitoring of blood pressure using optical Ballistocardiography and Photoplethysmograph approaches.

    PubMed

    Chen, Zhihao; Yang, Xiufeng; Teo, Ju Teng; Ng, Soon Huat

    2013-01-01

    A new all optical method for long term and continuous blood pressure measurement and monitoring without using cuffs is proposed by using Ballistocardiography (BCG) and Photoplethysmograph (PPG). Based on BCG signal and PPG signal, a time delay between these two signals is obtained to calculate both systolic blood pressure and diastolic blood pressure via linear regression analysis. The fabricated noninvasive blood pressure monitoring device consists of a fiber sensor mat to measure BCG signal and a SpO2 sensor to measure PPG signal. A commercial digital oscillometric blood pressure meter is used to obtain reference values and for calibration. It has been found that by comparing with the reference device, our prototype has typical means and standard deviations of 9+/-5.6 mmHg for systolic blood pressure, 1.8+/-1.3 mmHg for diastolic blood pressure and 0.6+/-0.9 bpm for pulse rate, respectively. If the fiber optic SpO2 probe is used, this new all fiber cuffless noninvasive blood pressure monitoring device will truly be a MRI safe blood pressure measurement and monitoring device.

  1. A wireless portable system with microsensors for monitoring respiratory diseases.

    PubMed

    Cao, Zhe; Zhu, Rong; Que, Rui-Yi

    2012-11-01

    A wireless portable monitoring system for respiratory diseases using microsensors is proposed. The monitoring system consists of two sensor nodes integrating with Bluetooth transmitters that measure user's respiratory airflow, blood oxygen saturation, and body posture. The utility of micro-hot-film flow sensor makes the monitor can acquire comprehensive respiration parameters which are useful for diagnoses of obstructive sleep apnea, chronic obstructive pulmonary disease, and asthma. The system can serve as both sleep recorder and spirometer. Additionally, a mobile phone or a PC connected to the Internet serving as a monitoring and transfer terminal makes telemedicine achievable. Several experiments were conducted to verify the feasibility and effectiveness of the proposed system for monitoring and diagnosing OSA, COPD, and asthma.

  2. The respiratory system.

    PubMed

    Zifko, U; Chen, R

    1996-10-01

    Neurological disorders frequently contribute to respiratory failure in critically ill patients. They may be the primary reason for the initiation of mechanical ventilation, or may develop later as a secondary complication. Disorders of the central nervous system leading to respiratory failure include metabolic encephalopathies, acute stroke, lesions of the motor cortex and brain-stem respiratory centres, and their descending pathways. Guillan-Barré syndrome, critical illness polyneuropathy and acute quadriplegic myopathy are the more common neuromuscular causes of respiratory failure. Clinical observations and pulmonary function tests are important in monitoring respiratory function. Respiratory electrophysiological studies are useful in the investigation and monitoring of respiratory failure. Transcortical and cervical magnetic stimulation can assess the central respiratory drive, and may be useful in determining the prognosis in ventilated patients, with cervical cord dysfunction. It is also helpful in the assessment of failure to wean, which is often caused by a combination of central and peripheral nervous system disorders. Phrenic nerve conduction studies and needle electromyography of the diaphragm and chest wall muscles are useful to characterize neuropathies and myopathies affecting the diaphragm. Repetitive phrenic nerve stimulation can assess neuromuscular transmission defects. It is important to identify patients at risk of respiratory failure. They should be carefully monitored and mechanical ventilation should be initiated before the development of severe hypoxaemia.

  3. Noninvasive continuous blood pressure monitoring by the ClearSight system during robot-assisted laparoscopic radical prostatectomy.

    PubMed

    Sakai, Yoko; Yasuo M, Tsutsumi; Oyama, Takuro; Murakami, Chiaki; Kakuta, Nami; Tanaka, Katsuya

    2018-01-01

    Robot-assisted laparoscopic radical prostatectomy (RALRP) is commonly performed in the surgical treatment of prostate cancer. However, the steep Trendelenburg position (25) and pneumoperitoneum required for this procedure can sometimes cause hemodynamic changes. Although blood pressure is traditionally monitored invasively during RALRP, the ClearSight system (BMEYE, Amsterdam, The Netherlands) enables a totally noninvasive and simple continuous blood pressure and cardiac output monitoring based on finger arterial pressure pulse contour analysis. We therefore investigated whether noninvasive continuous arterial blood pressure measurements using the ClearSight system were comparable to those obtained invasively in patients undergoing RALRP. Ten patients scheduled for RALRP with American Society of Anesthesiologists physical status I-II were included in this study. At each of the seven defined time points, noninvasive and invasive blood pressure measurements were documented and compared in each patient using Bland-Altman analysis. Although the blood pressure measured with the ClearSight system correlated with that measured invasively, a large difference between the values obtained by the two devices was noted. The ClearSight system was unable to detect blood pressure accurately during RALRP, suggesting that blood pressure monitoring using this device alone is not feasible in this small patient population. J. Med. Invest. 65:69-73, February, 2018.

  4. Extensive Core Microbiome in Drone-Captured Whale Blow Supports a Framework for Health Monitoring

    PubMed Central

    Miller, Carolyn A.; Moore, Michael J.; Durban, John W.; Fearnbach, Holly; Barrett-Lennard, Lance G.

    2017-01-01

    ABSTRACT The pulmonary system is a common site for bacterial infections in cetaceans, but very little is known about their respiratory microbiome. We used a small, unmanned hexacopter to collect exhaled breath condensate (blow) from two geographically distinct populations of apparently healthy humpback whales (Megaptera novaeangliae), sampled in the Massachusetts coastal waters off Cape Cod (n = 17) and coastal waters around Vancouver Island (n = 9). Bacterial and archaeal small-subunit rRNA genes were amplified and sequenced from blow samples, including many of sparse volume, as well as seawater and other controls, to characterize the associated microbial community. The blow microbiomes were distinct from the seawater microbiomes and included 25 phylogenetically diverse bacteria common to all sampled whales. This core assemblage comprised on average 36% of the microbiome, making it one of the more consistent animal microbiomes studied to date. The closest phylogenetic relatives of 20 of these core microbes were previously detected in marine mammals, suggesting that this core microbiome assemblage is specialized for marine mammals and may indicate a healthy, noninfected pulmonary system. Pathogen screening was conducted on the microbiomes at the genus level, which showed that all blow and few seawater microbiomes contained relatives of bacterial pathogens; no known cetacean respiratory pathogens were detected in the blow. Overall, the discovery of a shared large core microbiome in humpback whales is an important advancement for health and disease monitoring of this species and of other large whales. IMPORTANCE The conservation and management of large whales rely in part upon health monitoring of individuals and populations, and methods generally necessitate invasive sampling. Here, we used a small, unmanned hexacopter drone to noninvasively fly above humpback whales from two populations, capture their exhaled breath (blow), and examine the associated microbiome. In the first extensive examination of the large-whale blow microbiome, we present surprising results about the discovery of a large core microbiome that was shared across individual whales from geographically separated populations in two ocean basins. We suggest that this core microbiome, in addition to other microbiome characteristics, could be a useful feature for health monitoring of large whales worldwide. PMID:29034331

  5. Extensive Core Microbiome in Drone-Captured Whale Blow Supports a Framework for Health Monitoring.

    PubMed

    Apprill, Amy; Miller, Carolyn A; Moore, Michael J; Durban, John W; Fearnbach, Holly; Barrett-Lennard, Lance G

    2017-01-01

    The pulmonary system is a common site for bacterial infections in cetaceans, but very little is known about their respiratory microbiome. We used a small, unmanned hexacopter to collect exhaled breath condensate (blow) from two geographically distinct populations of apparently healthy humpback whales ( Megaptera novaeangliae ), sampled in the Massachusetts coastal waters off Cape Cod ( n = 17) and coastal waters around Vancouver Island ( n = 9). Bacterial and archaeal small-subunit rRNA genes were amplified and sequenced from blow samples, including many of sparse volume, as well as seawater and other controls, to characterize the associated microbial community. The blow microbiomes were distinct from the seawater microbiomes and included 25 phylogenetically diverse bacteria common to all sampled whales. This core assemblage comprised on average 36% of the microbiome, making it one of the more consistent animal microbiomes studied to date. The closest phylogenetic relatives of 20 of these core microbes were previously detected in marine mammals, suggesting that this core microbiome assemblage is specialized for marine mammals and may indicate a healthy, noninfected pulmonary system. Pathogen screening was conducted on the microbiomes at the genus level, which showed that all blow and few seawater microbiomes contained relatives of bacterial pathogens; no known cetacean respiratory pathogens were detected in the blow. Overall, the discovery of a shared large core microbiome in humpback whales is an important advancement for health and disease monitoring of this species and of other large whales. IMPORTANCE The conservation and management of large whales rely in part upon health monitoring of individuals and populations, and methods generally necessitate invasive sampling. Here, we used a small, unmanned hexacopter drone to noninvasively fly above humpback whales from two populations, capture their exhaled breath (blow), and examine the associated microbiome. In the first extensive examination of the large-whale blow microbiome, we present surprising results about the discovery of a large core microbiome that was shared across individual whales from geographically separated populations in two ocean basins. We suggest that this core microbiome, in addition to other microbiome characteristics, could be a useful feature for health monitoring of large whales worldwide.

  6. BreathSens: A Continuous On-Bed Respiratory Monitoring System With Torso Localization Using an Unobtrusive Pressure Sensing Array.

    PubMed

    Liu, Jason J; Huang, Ming-Chun; Xu, Wenyao; Zhang, Xiaoyi; Stevens, Luke; Alshurafa, Nabil; Sarrafzadeh, Majid

    2015-09-01

    The ability to continuously monitor respiration rates of patients in homecare or in clinics is an important goal. Past research showed that monitoring patient breathing can lower the associated mortality rates for long-term bedridden patients. Nowadays, in-bed sensors consisting of pressure sensitive arrays are unobtrusive and are suitable for deployment in a wide range of settings. Such systems aim to extract respiratory signals from time-series pressure sequences. However, variance of movements, such as unpredictable extremities activities, affect the quality of the extracted respiratory signals. BreathSens, a high-density pressure sensing system made of e-Textile, profiles the underbody pressure distribution and localizes torso area based on the high-resolution pressure images. With a robust bodyparts localization algorithm, respiratory signals extracted from the localized torso area are insensitive to arbitrary extremities movements. In a study of 12 subjects, BreathSens demonstrated its respiratory monitoring capability with variations of sleep postures, locations, and commonly tilted clinical bed conditions.

  7. Elimination of Drifts in Long-Duration Monitoring for Apnea-Hypopnea of Human Respiration.

    PubMed

    Jiang, Peng; Zhu, Rong

    2016-10-25

    This paper reports a methodology to eliminate an uncertain baseline drift in respiratory monitoring using a thermal airflow sensor exposed in a high humidity environment. Human respiratory airflow usually contains a large amount of moisture (relative humidity, RH > 85%). Water vapors in breathing air condense gradually on the surface of the sensor so as to form a thin water film that leads to a significant sensor drift in long-duration respiratory monitoring. The water film is formed by a combination of condensation and evaporation, and therefore the behavior of the humidity drift is complicated. Fortunately, the exhale and inhale responses of the sensor exhibit distinguishing features that are different from the humidity drift. Using a wavelet analysis method, we removed the baseline drift of the sensor and successfully recovered the respiratory waveform. Finally, we extracted apnea-hypopnea events from the respiratory signals monitored in whole-night sleeps of patients and compared them with golden standard polysomnography (PSG) results.

  8. Elimination of Drifts in Long-Duration Monitoring for Apnea-Hypopnea of Human Respiration

    PubMed Central

    Jiang, Peng; Zhu, Rong

    2016-01-01

    This paper reports a methodology to eliminate an uncertain baseline drift in respiratory monitoring using a thermal airflow sensor exposed in a high humidity environment. Human respiratory airflow usually contains a large amount of moisture (relative humidity, RH > 85%). Water vapors in breathing air condense gradually on the surface of the sensor so as to form a thin water film that leads to a significant sensor drift in long-duration respiratory monitoring. The water film is formed by a combination of condensation and evaporation, and therefore the behavior of the humidity drift is complicated. Fortunately, the exhale and inhale responses of the sensor exhibit distinguishing features that are different from the humidity drift. Using a wavelet analysis method, we removed the baseline drift of the sensor and successfully recovered the respiratory waveform. Finally, we extracted apnea-hypopnea events from the respiratory signals monitored in whole-night sleeps of patients and compared them with golden standard polysomnography (PSG) results. PMID:27792151

  9. Determinants of noninvasive ventilation success or failure in morbidly obese patients in acute respiratory failure.

    PubMed

    Lemyze, Malcolm; Taufour, Pauline; Duhamel, Alain; Temime, Johanna; Nigeon, Olivier; Vangrunderbeeck, Nicolas; Barrailler, Stéphanie; Gasan, Gaëlle; Pepy, Florent; Thevenin, Didier; Mallat, Jihad

    2014-01-01

    Acute respiratory failure (ARF) is a common life-threatening complication in morbidly obese patients with obesity hypoventilation syndrome (OHS). We aimed to identify the determinants of noninvasive ventilation (NIV) success or failure for this indication. We prospectively included 76 consecutive patients with BMI>40 kg/m2 diagnosed with OHS and treated by NIV for ARF in a 15-bed ICU of a tertiary hospital. NIV failed to reverse ARF in only 13 patients. Factors associated with NIV failure included pneumonia (n = 12/13, 92% vs n = 9/63, 14%; p<0.0001), high SOFA (10 vs 5; p<0.0001) and SAPS2 score (63 vs 39; p<0.0001) at admission. These patients often experienced poor outcome despite early resort to endotracheal intubation (in-hospital mortality, 92.3% vs 17.5%; p<0.001). The only factor significantly associated with successful response to NIV was idiopathic decompensation of OHS (n = 30, 48% vs n = 0, 0%; p = 0.001). In the NIV success group (n = 63), 33 patients (53%) experienced a delayed response to NIV (with persistent hypercapnic acidosis during the first 6 hours). Multiple organ failure and pneumonia were the main factors associated with NIV failure and death in morbidly obese patients in hypoxemic ARF. On the opposite, NIV was constantly successful and could be safely pushed further in case of severe hypercapnic acute respiratory decompensation of OHS.

  10. Initiation of non-invasive ventilation in amyotrophic lateral sclerosis and clinical practice guidelines: Single-centre, retrospective, descriptive study in a national reference centre.

    PubMed

    Georges, Marjolaine; Golmard, Jean-Louis; Llontop, Claudia; Shoukri, Amr; Salachas, François; Similowski, Thomas; Morelot-Panzini, Capucine; Gonzalez-Bermejo, Jésus

    2017-02-01

    In amyotrophic lateral sclerosis (ALS), respiratory muscle weakness leads to respiratory failure. Non-invasive ventilation (NIV) maintains adequate ventilation in ALS patients. NIV alleviates symptoms and improves survival. In 2006, French guidelines established criteria for NIV initiation based on limited evidence. Their impact on clinical practice remains unknown. Our objective was to describe NIV initiation practices of the main French ALS tertiary referral centre with respect to guidelines. In this retrospective descriptive study, 624 patients followed in a single national reference centre began NIV between 2005 and 2013. We analysed criteria used to initiate NIV, including symptoms, PaCO 2 , forced vital capacity, maximal inspiratory pressures and time spent with SpO 2 <90% at night. At NIV initiation, 90% of patients were symptomatic. Median PaCO 2 was 48 mmHg. The main criterion to initiate NIV was 'symptoms' followed by 'hypercapnia' in 42% and 34% of cases, respectively. NIV was initiated on functional parameters in only 5% of cases. Guidelines were followed in 81% of cases. In conclusion, despite compliance with French guidelines, the majority of patients are treated at the stage of symptomatic daytime hypoventilation, which suggests that NIV is initiated late in the course of ALS. Whether this practice could be improved by changing guidelines or increasing respiratory-dedicated resources remains to be determined.

  11. [Possibilities of bi-level positive pressure ventilation in chronic hypoventilation].

    PubMed

    Saaresranta, Tarja; Anttalainen, Ulla; Polo, Olli

    2011-01-01

    During the last decade, noninvasive bi-level positive pressure ventilation has enabled respiratory support in inpatient wards and at home. In many cases, a bi-level airway pressure ventilator can be used to avoid artificial airway and respirator therapy, and may shorten hospital stay and save costs. The treatment alleviates the patient's dyspnea and fatigue, whereby the quality of life improves, and in certain situations also the life span increases. The implementation of bi-level positive pressure ventilation by the physician requires knowledge of the basics of respiratory physiology and familiarization with the bi-level airway pressure ventilator.

  12. Prototype development of an electrical impedance based simultaneous respiratory and cardiac monitoring system for gated radiotherapy.

    PubMed

    Kohli, Kirpal; Liu, Jeff; Schellenberg, Devin; Karvat, Anand; Parameswaran, Ash; Grewal, Parvind; Thomas, Steven

    2014-10-14

    In radiotherapy, temporary translocations of the internal organs and tumor induced by respiratory and cardiac activities can undesirably lead to significantly lower radiation dose on the targeted tumor but more harmful radiation on surrounding healthy tissues. Respiratory and cardiac gated radiotherapy offers a potential solution for the treatment of tumors located in the upper thorax. The present study focuses on the design and development of simultaneous acquisition of respiratory and cardiac signal using electrical impedance technology for use in dual gated radiotherapy. An electronic circuitry was developed for monitoring the bio-impedance change due to respiratory and cardiac motions and extracting the cardiogenic ECG signal. The system was analyzed in terms of reliability of signal acquisition, time delay, and functionality in a high energy radiation environment. The resulting signal of the system developed was also compared with the output of the commercially available Real-time Position Management™ (RPM) system in both time and frequency domains. The results demonstrate that the bioimpedance-based method can potentially provide reliable tracking of respiratory and cardiac motion in humans, alternative to currently available methods. When compared with the RPM system, the impedance-based system developed in the present study shows similar output pattern but different sensitivities in monitoring different respiratory rates. The tracking of cardiac motion was more susceptible to interference from other sources than respiratory motion but also provided synchronous output compared with the ECG signal extracted. The proposed hardware-based implementation was observed to have a worst-case time delay of approximately 33 ms for respiratory monitoring and 45 ms for cardiac monitoring. No significant effect on the functionality of the system was observed when it was tested in a radiation environment with the electrode lead wires directly exposed to high-energy X-Rays. The developed system capable of rendering quality signals for tracking both respiratory and cardiac motions can potentially provide a solution for simultaneous dual-gated radiotherapy.

  13. Development of a dedicated isotope mass spectrometer for the noninvasive diagnostics of humans infected with Helicobacter Pylori

    NASA Astrophysics Data System (ADS)

    Blashenkov, N. M.; Sheshenya, E. S.; Solov'ev, S. M.; Gall', L. N.; Sachenko, V. M.; Zarutskii, I. V.; Gall', N. R.

    2013-06-01

    A dedicated isotope mass spectrometer for the noninvasive diagnostics of humans infected with Helicobacter Pylori using the isotope respiratory test is developed. A low-aberration mass analyzer is calculated, an input system that makes it possible to eliminate the memory effects is developed, and a small-size ion detector is constructed. The mass spectrometer is created, and the tests are performed. The measurement accuracy of the 13C/12C and 16O/18O isotope ratios are 1.7 and 2.2‰, respectively. Preliminary medical tests show that the spectrometer can be employed for the desired diagnostics.

  14. [Reflections on the use of non-invasive mechanical ventilation in acute respiratory failure].

    PubMed

    Scala, Raffaele

    2012-12-01

    Given its prevalence into the clinical practice, non-invasive ventilation (NIV) can be included among the cornerstones of medicine. Just think of the acute applications of NIV which are in constant expansion, from COPD exacerbation to severe de novo hypoxemia, from postoperative distress to extra-hospital use in acute pulmonary edema, from ongoing support of interventional procedures to delicate strategies for end of life in terminally ill oncologic and non-oncologic patients. The thought should be focused on how, by whom, where and to whom is delivered this mode of artificial ventilation to avoid the risk of trivialization and flattening.

  15. On better estimating and normalizing the relationship between clinical parameters: comparing respiratory modulations in the photoplethysmogram and blood pressure signal (DPOP versus PPV).

    PubMed

    Addison, Paul S; Wang, Rui; Uribe, Alberto A; Bergese, Sergio D

    2015-01-01

    DPOP (ΔPOP or Delta-POP) is a noninvasive parameter which measures the strength of respiratory modulations present in the pulse oximeter waveform. It has been proposed as a noninvasive alternative to pulse pressure variation (PPV) used in the prediction of the response to volume expansion in hypovolemic patients. We considered a number of simple techniques for better determining the underlying relationship between the two parameters. It was shown numerically that baseline-induced signal errors were asymmetric in nature, which corresponded to observation, and we proposed a method which combines a least-median-of-squares estimator with the requirement that the relationship passes through the origin (the LMSO method). We further developed a method of normalization of the parameters through rescaling DPOP using the inverse gradient of the linear fitted relationship. We propose that this normalization method (LMSO-N) is applicable to the matching of a wide range of clinical parameters. It is also generally applicable to the self-normalizing of parameters whose behaviour may change slightly due to algorithmic improvements.

  16. On Better Estimating and Normalizing the Relationship between Clinical Parameters: Comparing Respiratory Modulations in the Photoplethysmogram and Blood Pressure Signal (DPOP versus PPV)

    PubMed Central

    Addison, Paul S.; Wang, Rui; Uribe, Alberto A.; Bergese, Sergio D.

    2015-01-01

    DPOP (ΔPOP or Delta-POP) is a noninvasive parameter which measures the strength of respiratory modulations present in the pulse oximeter waveform. It has been proposed as a noninvasive alternative to pulse pressure variation (PPV) used in the prediction of the response to volume expansion in hypovolemic patients. We considered a number of simple techniques for better determining the underlying relationship between the two parameters. It was shown numerically that baseline-induced signal errors were asymmetric in nature, which corresponded to observation, and we proposed a method which combines a least-median-of-squares estimator with the requirement that the relationship passes through the origin (the LMSO method). We further developed a method of normalization of the parameters through rescaling DPOP using the inverse gradient of the linear fitted relationship. We propose that this normalization method (LMSO-N) is applicable to the matching of a wide range of clinical parameters. It is also generally applicable to the self-normalizing of parameters whose behaviour may change slightly due to algorithmic improvements. PMID:25691912

  17. Diffusion-weighted imaging in pediatric body MR imaging: principles, technique, and emerging applications.

    PubMed

    Chavhan, Govind B; Alsabban, Zehour; Babyn, Paul S

    2014-01-01

    Diffusion-weighted (DW) imaging is an emerging technique in body imaging that provides indirect information about the microenvironment of tissues and lesions and helps detect, characterize, and follow up abnormalities. Two main challenges in the application of DW imaging to body imaging are the decreased signal-to-noise ratio of body tissues compared with neuronal tissues due to their shorter T2 relaxation time, and image degradation related to physiologic motion (eg, respiratory motion). Use of smaller b values and newer motion compensation techniques allow the evaluation of anatomic structures with DW imaging. DW imaging can be performed as a breath-hold sequence or a free-breathing sequence with or without respiratory triggering. Depending on the mobility of water molecules in their microenvironment, different normal tissues have different signals at DW imaging. Some normal tissues (eg, lymph nodes, spleen, ovarian and testicular parenchyma) are diffusion restricted, whereas others (eg, gallbladder, corpora cavernosa, endometrium, cartilage) show T2 shine-through. Epiphyses that contain fatty marrow and bone cortex appear dark on both DW images and apparent diffusion coefficient maps. Current and emerging applications of DW imaging in pediatric body imaging include tumor detection and characterization, assessment of therapy response and monitoring of tumors, noninvasive detection and grading of liver fibrosis and cirrhosis, detection of abscesses, and evaluation of inflammatory bowel disease. RSNA, 2014

  18. Fluorescence diagnosis of upper respiratory tract infections

    NASA Astrophysics Data System (ADS)

    Blanco, Kate C.; Inada, Natalia M.; Kurachi, Cristina; Bagnato, Vanderlei S.

    2015-06-01

    The pharyngitis and laryngitis are respiratory tract infections highly common. Pharyngitis can be accompanied by fever, especially if caused by a systemic infection. Laryngitis is an inflammation of your voice box (larynx) from irritation or infection. The conventional treatment is the antibiotics administration, which may be responsible by an increase of identification of bacterial strains resistant to drug. This fact associated to high incidence of these infections become important to develop new technologies for diagnosis. This study aims to evaluate the use of widefield fluorescence imaging for the characterization of oropharynx infections, in order to diagnose the bacteria colonization. The imaging system for wide field fluorescence visualization is Evince® (MMOptics, São Carlos, SP, Brazil) coupled to an Apple iPhone® cell phone device. The system consists of Light Emitting Diodes (LEDs) operating in the violet blue region centered at green-red spectrum 450 nm and optical filters that allow viewing of fluorescence. A tongue depressor was adapted to Evince® for mouth opening. The same images were captured with white light and fluorescence with an optical system. The red fluorescence may be a bacterial marker for physiological monitoring of oropharynx infection processes. The bacterial biofilm on tissue were assigned to the presence of protoporphyrin IX. This work indicates that the autofluorescence of the tissue may be used as a non-invasive technique to aid in the oropharynx infection diagnostic.

  19. Invasive and noninvasive hemodynamic monitoring of patients with cerebrovascular accidents.

    PubMed Central

    Velmahos, G C; Wo, C C; Demetriades, D; Bishop, M H; Shoemaker, W C

    1998-01-01

    Seventeen patients with hemodynamic instability from acute cerebrovascular accidents were evaluated shortly after arrival at the emergency department of a university-run county hospital with both invasive Swan-Ganz pulmonary artery catheter placement and a new, noninvasive, thoracic electrical bioimpedance device. Values were recorded and temporal patterns of survivors and nonsurvivors were described. Cardiac indices obtained simultaneously by the 2 techniques were compared. Of the 17 patients, 11 (65%) died. Survivors had higher values than nonsurvivors for mean arterial pressure, cardiac index, and oxygen saturation, delivery, and consumption at comparable times. Cardiac index values, as measured by invasive and noninvasive methods, were correlated. We concluded that hemodynamic monitoring in an acute care setting may recognize temporal circulatory patterns associated with outcome. Noninvasive electrical bioimpedance technology offers a new method for early hemodynamic evaluation. Further research in this area is warranted. PMID:9682626

  20. Tissue-Informative Mechanism for Wearable Non-invasive Continuous Blood Pressure Monitoring

    NASA Astrophysics Data System (ADS)

    Woo, Sung Hun; Choi, Yun Young; Kim, Dae Jung; Bien, Franklin; Kim, Jae Joon

    2014-10-01

    Accurate continuous direct measurement of the blood pressure is currently available thru direct invasive methods via intravascular needles, and is mostly limited to use during surgical procedures or in the intensive care unit (ICU). Non-invasive methods that are mostly based on auscultation or cuff oscillometric principles do provide relatively accurate measurement of blood pressure. However, they mostly involve physical inconveniences such as pressure or stress on the human body. Here, we introduce a new non-invasive mechanism of tissue-informative measurement, where an experimental phenomenon called subcutaneous tissue pressure equilibrium is revealed and related for application in detection of absolute blood pressure. A prototype was experimentally verified to provide an absolute blood pressure measurement by wearing a watch-type measurement module that does not cause any discomfort. This work is supposed to contribute remarkably to the advancement of continuous non-invasive mobile devices for 24-7 daily-life ambulatory blood-pressure monitoring.

  1. Fast noninvasive eye-tracking and eye-gaze determination for biomedical and remote monitoring applications

    NASA Astrophysics Data System (ADS)

    Talukder, Ashit; Morookian, John M.; Monacos, Steve P.; Lam, Raymond K.; Lebaw, C.; Bond, A.

    2004-04-01

    Eyetracking is one of the latest technologies that has shown potential in several areas including human-computer interaction for people with and without disabilities, and for noninvasive monitoring, detection, and even diagnosis of physiological and neurological problems in individuals. Current non-invasive eyetracking methods achieve a 30 Hz rate with possibly low accuracy in gaze estimation, that is insufficient for many applications. We propose a new non-invasive visual eyetracking system that is capable of operating at speeds as high as 6-12 KHz. A new CCD video camera and hardware architecture is used, and a novel fast image processing algorithm leverages specific features of the input CCD camera to yield a real-time eyetracking system. A field programmable gate array (FPGA) is used to control the CCD camera and execute the image processing operations. Initial results show the excellent performance of our system under severe head motion and low contrast conditions.

  2. Glucose Sensing for Diabetes Monitoring: Recent Developments

    PubMed Central

    Bruen, Danielle; Delaney, Colm; Florea, Larisa

    2017-01-01

    This review highlights recent advances towards non-invasive and continuous glucose monitoring devices, with a particular focus placed on monitoring glucose concentrations in alternative physiological fluids to blood. PMID:28805693

  3. Hemodynamic monitoring in the critically ill.

    PubMed

    Voga, G

    1995-06-01

    Monitoring of vital functions is one of the most important and essential tools in the management of critically ill patients in the ICU. Today it is possible to detect and analyze a great variety of physiological signals by various noninvasive and invasive techniques. An intensivist should be able to select and perform the most appropriate monitoring method for the individual patient considering risk-benefit ratio of the particular monitoring technique and the need for immediate therapy, specific diagnosis, continuous monitoring and evaluation of morphology should be included. Despite rapid development of noninvasive monitoring techniques, invasive hemodynamic monitoring in still one of the most basic ICU procedures. It enables monitoring of pressures, flow and saturation, pressures in the systemic and pulmonary circulation, estimation of cardiac performance and judgment of the adequacy of the cardiocirculatory system. Carefully and correctly obtained information are basis for proper hemodynamic assessment which usually effects the therapeutic decisions.

  4. Review of optical coherence tomography in oncology

    NASA Astrophysics Data System (ADS)

    Wang, Jianfeng; Xu, Yang; Boppart, Stephen A.

    2017-12-01

    The application of optical coherence tomography (OCT) in the field of oncology has been prospering over the past decade. OCT imaging has been used to image a broad spectrum of malignancies, including those arising in the breast, brain, bladder, the gastrointestinal, respiratory, and reproductive tracts, the skin, and oral cavity, among others. OCT imaging has initially been applied for guiding biopsies, for intraoperatively evaluating tumor margins and lymph nodes, and for the early detection of small lesions that would often not be visible on gross examination, tasks that align well with the clinical emphasis on early detection and intervention. Recently, OCT imaging has been explored for imaging tumor cells and their dynamics, and for the monitoring of tumor responses to treatments. This paper reviews the evolution of OCT technologies for the clinical application of OCT in surgical and noninvasive interventional oncology procedures and concludes with a discussion of the future directions for OCT technologies, with particular emphasis on their applications in oncology.

  5. Kinect2 - respiratory movement detection study.

    PubMed

    Rihana, Sandy; Younes, Elie; Visvikis, Dimitris; Fayad, Hadi

    2016-08-01

    Radiotherapy is one of the main cancer treatments. It consists in irradiating tumor cells to destroy them while sparing healthy tissue. The treatment is planned based on Computed Tomography (CT) and is delivered over fractions during several days. One of the main challenges is replacing patient in the same position every day to irradiate the tumor volume while sparing healthy tissues. Many patient positioning techniques are available. They are both invasive and not accurate performed using tattooed marker on the patient's skin aligned with a laser system calibrated in the treatment room or irradiating using X-ray. Currently systems such as Vision RT use two Time of Flight cameras. Time of Flight cameras have the advantage of having a very fast acquisition rate allows the real time monitoring of patient movement and patient repositioning. The purpose of this work is to test the Microsoft Kinect2 camera for potential use for patient positioning and respiration trigging. This type of Time of Flight camera is non-invasive and costless which facilitate its transfer to clinical practice.

  6. Noninvasive measurement of renal blood flow by magnetic resonance imaging in rats.

    PubMed

    Romero, Cesar A; Cabral, Glauber; Knight, Robert A; Ding, Guangliang; Peterson, Edward L; Carretero, Oscar A

    2018-01-01

    Renal blood flow (RBF) provides important information regarding renal physiology and nephropathies. Arterial spin labeling-magnetic resonance imaging (ASL-MRI) is a noninvasive method of measuring blood flow without exogenous contrast media. However, low signal-to-noise ratio and respiratory motion artifacts are challenges for RBF measurements in small animals. Our objective was to evaluate the feasibility and reproducibility of RBF measurements by ASL-MRI using respiratory-gating and navigator correction methods to reduce motion artifacts. ASL-MRI images were obtained from the kidneys of Sprague-Dawley (SD) rats on a 7-Tesla Varian MRI system with a spin-echo imaging sequence. After 4 days, the study was repeated to evaluate its reproducibility. RBF was also measured in animals under unilateral nephrectomy and in renal artery stenosis (RST) to evaluate the sensitivity in high and low RBF models, respectively. RBF was also evaluated in Dahl salt-sensitive (SS) rats and spontaneous hypertensive rats (SHR). In SD rats, the cortical RBFs (cRBF) were 305 ± 59 and 271.8 ± 39 ml·min -1 ·100 g tissue -1 in the right and left kidneys, respectively. Retest analysis revealed no differences ( P = 0.2). The test-retest reliability coefficient was 92 ± 5%. The cRBFs before and after the nephrectomy were 296.8 ± 30 and 428.2 ± 45 ml·min -1 ·100 g tissue -1 ( P = 0.02), respectively. The kidneys with RST exhibited a cRBF decrease compared with sham animals (86 ± 17.6 vs. 198 ± 33.7 ml·min -1 ·100 g tissue -1 ; P < 0.01). The cRBFs in SD, Dahl-SS, and SHR rats were not different ( P = 0.35). We conclude that ASL-MRI performed with navigator correction and respiratory gating is a feasible and reliable noninvasive method for measuring RBF in rats.

  7. A mainstream monitoring system for respiratory CO2 concentration and gasflow.

    PubMed

    Yang, Jiachen; Chen, Bobo; Burk, Kyle; Wang, Haitao; Zhou, Jianxiong

    2016-08-01

    Continuous respiratory gas monitoring is an important tool for clinical monitoring. In particular, measurement of respiratory [Formula: see text] concentration and gasflow can reflect the status of a patient by providing parameters such as volume of carbon dioxide, end-tidal [Formula: see text] respiratory rate and alveolar deadspace. However, in the majority of previous work, [Formula: see text] concentration and gasflow have been studied separately. This study focuses on a mainstream system which simultaneously measures respiratory [Formula: see text] concentration and gasflow at the same location, allowing for volumetric capnography to be implemented. A non-dispersive infrared monitor is used to measure [Formula: see text] concentration and a differential pressure sensor is used to measure gasflow. In developing this new device, we designed a custom airway adapter which can be placed in line with the breathing circuit and accurately monitor relevant respiratory parameters. Because the airway adapter is used both for capnography and gasflow, our system reduces mechanical deadspace. The finite element method was used to design the airway adapter which can provide a strong differential pressure while reducing airway resistance. Statistical analysis using the coefficient of variation was performed to find the optimal driving voltage of the pressure transducer. Calibration between variations and flows was used to avoid pressure signal drift. We carried out targeted experiments using the proposed device and confirmed that the device can produce stable signals.

  8. Non-invasive monitoring of spreading depression.

    PubMed

    Bastany, Zoya J R; Askari, Shahbaz; Dumont, Guy A; Speckmann, Erwin-Josef; Gorji, Ali

    2016-10-01

    Spreading depression (SD), a slow propagating depolarization wave, plays an important role in pathophysiology of different neurological disorders. Yet, research into SD-related disorders has been hampered by the lack of non-invasive recording techniques of SD. Here we compared the manifestations of SD in continuous non-invasive electroencephalogram (EEG) recordings to invasive electrocorticographic (ECoG) recordings in order to obtain further insights into generator structures and electrogenic mechanisms of surface recording of SD. SD was induced by KCl application and simultaneous SD recordings were performed by scalp EEG as well as ECoG electrodes of somatosensory neocortex of rats using a novel homemade EEG amplifier, AgCl recording electrodes, and high chloride conductive gel. Different methods were used to analyze the data; including the spectrogram, bi-spectrogram, pattern distribution, relative spectrum power, and multivariable Gaussian fit analysis. The negative direct current (DC) shifts recorded by scalp electrodes exhibited a high homogeneity to those recorded by ECoG electrodes. Furthermore, this novel method of recording and analysis was able to separate SD recorded by scalp electrodes from non-neuronal DC shifts induced by other potential generators, such as the skin, muscles, arteries, dura, etc. These data suggest a novel application for continuous non-invasive monitoring of DC potential changes, such as SD. Non-invasive monitoring of SD would allow early intervention and improve outcome in SD-related neurological disorders. Copyright © 2016 IBRO. All rights reserved.

  9. Efficacy of noninvasive volume targeted ventilation in patients with chronic respiratory failure due to kyphoscoliosis.

    PubMed

    Piesiak, P; Brzecka, A; Kosacka, M; Jankowska, R

    2015-01-01

    Severe kyphoscoliosis can cause chronic respiratory failure. Noninvasive mechanical ventilation (NIMV) is a new optional treatment for such patients. The aim of this study was to evaluate the effectiveness of average volume-assured pressure support (AVAPS) NIMV in patients with kyphoscoliotic chronic respiratory failure. The study was performed in 12 patients (mean age 49±11 years and body mass index 27.5±7.9 kg/m2) with advanced kyphoscoliosis complicated by severe respiratory failure (PaO2 6.68±0.34 kPa, SaO2 81.7±3.1%, PaCO2 9.51±1.08 kPa) treated by the NIMV. The short-term, after 5 days, and long-term, after 1 year of home treatment, efficacy of NIMV was evaluated. We found a significant improvement of diurnal PaO2 and PaCO2 on the 5th day of NIMV (an increase of 1.4±0.3 kPa and a decrease of 1.8±0.8 kPa, respectively; p<0.05) and after one year NIMV (an increase of 2.07±0.46 kPa and a decrease of 2.68±0.85 kPa, respectively; p<0.05). There was a significant increase of mean blood oxygen saturation during sleep on the 5th day (86.2±3.2%) and after 1 year of treatment (89.4±2.1%) compared with the baseline level (83.2±3.2%). The forced vital capacity also increased after 1 year (1,024±258 ml vs. the baseline 908±267 ml; p<0.05). The NIMV was well tolerated and no patient discontinued the treatment during the observation period. We conclude that AVAPS NIMV is an effective treatment option in kyphoscoliotic patients with chronic respiratory failure, resulting in a prompt and long-term improvement of daytime and nocturnal blood gas exchange.

  10. Non-invasive ventilation in acute respiratory failure in children

    PubMed Central

    Abadesso, Clara; Nunes, Pedro; Silvestre, Catarina; Matias, Ester; Loureiro, Helena; Almeida, Helena

    2012-01-01

    The aim of this paper is to assess the clinical efficacy of non-invasive ventilation (NIV) in avoiding endotracheal intubation (ETI), to demonstrate clinical and gasometric improvement and to identify predictive risk factors associated with NIV failure. An observational prospective clinical study was carried out. Included Patients with acute respiratory disease (ARD) treated with NIV, from November 2006 to January 2010 in a Pediatric Intensive Care Unit (PICU). NIV was used in 151 patients with acute respiratory failure (ARF). Patients were divided in two groups: NIV success and NIV failure, if ETI was required. Mean age was 7.2±20.3 months (median: 1 min: 0,3 max.: 156). Main diagnoses were bronchiolitis in 102 (67.5%), and pneumonia in 44 (29%) patients. There was a significant improvement in respiratory rate (RR), heart rate (HR), pH, and pCO2 at 2, 6, 12 and 24 hours after NIV onset (P<0.05) in both groups. Improvement in pulse oximetric saturation/fraction of inspired oxygen (SpO2/FiO2) was verified at 2, 4, 6, 12 and 24 hours after NIV onset in the success group (P<0.001). In the failure group, significant SpO2/FiO2 improvement was only observed in the first 4 hours. NIV failure occurred in 34 patients (22.5%). Risk factors for NIV failure were apnea, prematurity, pneumonia, and bacterial co-infection (P<0.05). Independent risk factors for NIV failure were apneia (P<0.001; odds ratio 15.8; 95% confidence interval: 3.42–71.4) and pneumonia (P<0.001, odds ratio 31.25; 95% confidence interval: 8.33–111.11). There were no major complications related with NIV. In conclusion this study demonstrates the efficacy of NIV as a form of respiratory support for children and infants with ARF, preventing clinical deterioration and avoiding ETI in most of the patients. Risk factors for failure were related with immaturity and severe infection. PMID:22802994

  11. Non-invasive ventilation in acute respiratory failure in children.

    PubMed

    Abadesso, Clara; Nunes, Pedro; Silvestre, Catarina; Matias, Ester; Loureiro, Helena; Almeida, Helena

    2012-04-02

    The aim of this paper is to assess the clinical efficacy of non-invasive ventilation (NIV) in avoiding endotracheal intubation (ETI), to demonstrate clinical and gasometric improvement and to identify predictive risk factors associated with NIV failure. An observational prospective clinical study was carried out. Included Patients with acute respiratory disease (ARD) treated with NIV, from November 2006 to January 2010 in a Pediatric Intensive Care Unit (PICU). NIV was used in 151 patients with acute respiratory failure (ARF). Patients were divided in two groups: NIV success and NIV failure, if ETI was required. Mean age was 7.2±20.3 months (median: 1 min: 0,3 max.: 156). Main diagnoses were bronchiolitis in 102 (67.5%), and pneumonia in 44 (29%) patients. There was a significant improvement in respiratory rate (RR), heart rate (HR), pH, and pCO(2) at 2, 6, 12 and 24 hours after NIV onset (P<0.05) in both groups. Improvement in pulse oximetric saturation/fraction of inspired oxygen (SpO(2)/FiO(2)) was verified at 2, 4, 6, 12 and 24 hours after NIV onset in the success group (P<0.001). In the failure group, significant SpO(2)/FiO(2) improvement was only observed in the first 4 hours. NIV failure occurred in 34 patients (22.5%). Risk factors for NIV failure were apnea, prematurity, pneumonia, and bacterial co-infection (P<0.05). Independent risk factors for NIV failure were apneia (P<0.001; odds ratio 15.8; 95% confidence interval: 3.42-71.4) and pneumonia (P<0.001, odds ratio 31.25; 95% confidence interval: 8.33-111.11). There were no major complications related with NIV. In conclusion this study demonstrates the efficacy of NIV as a form of respiratory support for children and infants with ARF, preventing clinical deterioration and avoiding ETI in most of the patients. Risk factors for failure were related with immaturity and severe infection.

  12. Delayed but successful response to noninvasive ventilation in COPD patients with acute hypercapnic respiratory failure.

    PubMed

    Lemyze, Malcolm; Bury, Quentin; Guiot, Aurélie; Jonard, Marie; Mohammad, Usman; Van Grunderbeeck, Nicolas; Gasan, Gaelle; Thevenin, Didier; Mallat, Jihad

    2017-01-01

    We evaluated a new noninvasive ventilation (NIV) protocol that allows the pursuit of NIV in the case of persistent severe respiratory acidosis despite a first NIV challenge in COPD patients with acute hypercapnic respiratory failure (AHRF). A prospective observational multicentric pilot study was conducted in three tertiary hospitals over a 12-month study period. A total of 155 consecutive COPD patients who were admitted for AHRF and treated by NIV were enrolled. Delayed response to NIV was defined as a significant clinical improvement in the first 48 h following NIV initiation despite a persistent severe respiratory acidosis (pH <7.30) after the first 2 h of NIV trial. NIV failed in only 10 patients (6.5%). Delayed responders to NIV (n=83, 53%) exhibited similar nutritional status, comorbidities, functional status, frailty score, dyspnea score, and severity score at admission, compared with early responders (n=62, 40%). Only age (66 vs 70 years in early responders; P =0.03) and encephalopathy score (3 [2-4] vs 3 [2-4] in early responders; P =0.015) were different among the responders. Inhospital mortality did not differ between responders to NIV (n=10, 12% for delayed responders vs n=10, 16% for early responders, P =0.49). A second episode of AHRF occurred in 20 responders (14%), equally distributed among early and delayed responders to NIV (n=9, 14.5% in early responders vs n=11, 13% in delayed responders; P =0.83), with a poor survival rate (n=1, 5%). Most of the COPD patients with AHRF have a successful outcome when NIV is pursued despite a persistent severe respiratory acidosis after the first NIV trial. The outcome of delayed responders is similar to the one of the early responders. On the contrary, the second episode of AHRF during the hospital stay carries a poor prognosis.

  13. Measurement of tissue optical properties with optical coherence tomography: Implication for noninvasive blood glucose concentration monitoring

    NASA Astrophysics Data System (ADS)

    Larin, Kirill V.

    Approximately 14 million people in the USA and more than 140 million people worldwide suffer from diabetes mellitus. The current glucose sensing technique involves a finger puncture several times a day to obtain a droplet of blood for analysis. There have been enormous efforts by many scientific groups and companies to quantify glucose concentration noninvasively using different optical techniques. However, these techniques face limitations associated with low sensitivity, accuracy, and insufficient specificity of glucose concentrations over a physiological range. Optical coherence tomography (OCT), a new technology, is being applied for noninvasive imaging in tissues with high resolution. OCT utilizes sensitive detection of photons coherently scattered from tissue. The high resolution of this technique allows for exceptionally accurate measurement of tissue scattering from a specific layer of skin compared with other optical techniques and, therefore, may provide noninvasive and continuous monitoring of blood glucose concentration with high accuracy. In this dissertation work I experimentally and theoretically investigate feasibility of noninvasive, real-time, sensitive, and specific monitoring of blood glucose concentration using an OCT-based biosensor. The studies were performed in scattering media with stable optical properties (aqueous suspensions of polystyrene microspheres and milk), animals (New Zealand white rabbits and Yucatan micropigs), and normal subjects (during oral glucose tolerance tests). The results of these studies demonstrated: (1) capability of the OCT technique to detect changes in scattering coefficient with the accuracy of about 1.5%; (2) a sharp and linear decrease of the OCT signal slope in the dermis with the increase of blood glucose concentration; (3) the change in the OCT signal slope measured during bolus glucose injection experiments (characterized by a sharp increase of blood glucose concentration) is higher than that measured in the glucose clamping experiments (characterized by slow, controlled increase of the blood glucose concentration); and (4) the accuracy of glucose concentration monitoring may substantially be improved if optimal dimensions of the probed skin area are used. The results suggest that high-resolution OCT technique has a potential for noninvasive, accurate, and continuous glucose monitoring with high sensitivity.

  14. Monitoring Species of Concern Using Noninvasive Genetic Sampling and Capture-Recapture Methods

    DTIC Science & Technology

    2016-11-01

    ABBREVIATIONS AICc Akaike’s Information Criterion with small sample size correction AZGFD Arizona Game and Fish Department BMGR Barry M. Goldwater...MNKA Minimum Number Known Alive N Abundance Ne Effective Population Size NGS Noninvasive Genetic Sampling NGS-CR Noninvasive Genetic...parameter estimates from capture-recapture models require sufficient sample sizes , capture probabilities and low capture biases. For NGS-CR, sample

  15. Cost-effectiveness of noninvasive ventilation for chronic obstructive pulmonary disease-related respiratory failure in Indian hospitals without ICU facilities.

    PubMed

    Patel, Shraddha P; Pena, Margarita E; Babcock, Charlene Irvin

    2015-01-01

    The majority of Indian hospitals do not provide intensive care unit (ICU) care or ward-based noninvasive positive pressure ventilation (NIV). Because no mechanical ventilation or NIV is available in these hospitals, the majority of patients suffering from respiratory failure die. To perform a cost-effective analysis of two strategies (ward-based NIV with concurrent standard treatment vs standard treatment alone) in chronic obstructive pulmonary disease (COPD) respiratory failure patients treated in Indian hospitals without ICU care. A decision-analytical model was created to compare the cost-effectiveness for the two strategies. Estimates from the literature were used for parameters in the model. Future costs were discounted at 3%. All costs were reported in USD (2012). One-way, two-way, and probabilistic sensitivity analysis were performed. The time horizon was lifetime and perspective was societal. The NIV strategy resulted in 17.7% more survival and was slightly more costly (increased cost of $101 (USD 2012) but resulted in increased quality-adjusted life-years (QALYs) (1.67 QALY). The cost-effectiveness (2012 USD)/QALY in the standard and NIV groups was $78/QALY ($535.02/6.82) and $75/QALY ($636.33/8.49), respectively. Incremental cost-effectiveness ratio (ICER) was only $61 USD/QALY. This was substantially lower than the gross domestic product (GDP) per capita for India (1489 USD), suggesting the NIV strategy was very cost effective. Using a 5% discount rate resulted in only minimally different results. Probabilistic analysis suggests that NIV strategy was preferred 100% of the time when willingness to pay was >$250 2012 USD. Ward-based NIV treatment is cost-effective in India, and may increase survival of patients with COPD respiratory failure when ICU is not available.

  16. Clinical review: Helmet and non-invasive mechanical ventilation in critically ill patients.

    PubMed

    Esquinas Rodriguez, Antonio M; Papadakos, Peter J; Carron, Michele; Cosentini, Roberto; Chiumello, Davide

    2013-04-25

    Non-invasive mechanical ventilation (NIV) has proved to be an excellent technique in selected critically ill patients with different forms of acute respiratory failure. However, NIV can fail on account of the severity of the disease and technical problems, particularly at the interface. The helmet could be an alternative interface compared to face mask to improve NIV success. We performed a clinical review to investigate the main physiological and clinical studies assessing the efficacy and related issues of NIV delivered with a helmet. A computerized search strategy of MEDLINE/PubMed (January 2000 to May 2012) and EMBASE (January 2000 to May 2012) was conducted limiting the search to retrospective, prospective, nonrandomized and randomized trials. We analyzed 152 studies from which 33 were selected, 12 physiological and 21 clinical (879 patients). The physiological studies showed that NIV with helmet could predispose to CO₂ rebreathing and increase the patients' ventilator asynchrony. The main indications for NIV were acute cardiogenic pulmonary edema, hypoxemic acute respiratory failure (community-acquired pneumonia, postoperative and immunocompromised patients) and hypercapnic acute respiratory failure. In 9 of the 21 studies the helmet was compared to a face mask during either continous positive airway pressure or pressure support ventilation. In eight studies oxygenation was similar in the two groups, while the intubation rate was similar in four and lower in three studies for the helmet group compared to face mask group. The outcome was similar in six studies. The tolerance was better with the helmet in six of the studies. Although these data are limited, NIV delivered by helmet could be a safe alternative to the face mask in patients with acute respiratory failure.

  17. The 6-minute walk test in chronic respiratory failure: does observed or predicted walk distance better reflect patient functional status?

    PubMed

    Güngör, Gökay; Karakurt, Zuhal; Adigüzel, Nalan; Aydin, Rüya Evin; Balci, Merih Kalamanoğlu; Saltürk, Cüneyt; Sancar, Raziye; Solmaz, Suat; Moçin, Özlem Yazicioğlu

    2013-05-01

    Acquiring 6-min walk test (6MWT) data from patients undergoing noninvasive mechanical ventilation due to chronic hypercapnic respiratory failure is limited. We aimed to assess whether the actual 6-min walk distance (6MWD) or the percent predicted 6MWD is a better reflection of the respiratory function of patients using home noninvasive ventilation (NIV) due to chronic hypercapnic respiratory failure. This was a cross-sectional observational study. The 6MWT was performed in subjects using home NIV. Diagnoses were grouped as COPD, obesity hypoventilation syndrome (OHS), kyphoscoliosis, and parenchymal lung disease. Sex, age, and body mass index (BMI) were used to calculate ideal 6MWD. Male: 1,140 m - (5.61 × BMI) - (6.94 × age), and subtract 153 m for the lower limit of normal. Female: 1,017 m - (6.24 × BMI) - (5.83 × age), and subtract 139 m for the lower limit of normal. The 6MWD and percent-of-predicted 6MWD were compared relative to arterial blood gas, spirometry values, and diagnosis. The 6MWT was performed in 144 subjects, median (IQR) age 62 y (55-71 y). The male/female ratio, median (IQR) 6MWD, and percent-of-predicted 6MWD values were: COPD 32/6, 316 m (226-390 m), and 59.4% (42.5-68.9%); OHS 24/28, 303 m (240-362 m), and 73.0% (63.0-82.0%); kyphoscoliosis 16/7, 420 m (318-462 m), and 70.5% (56.0-75.2%); and parenchymal lung disease 19/12, 333 m (273-372 m), and 67.1% (46.7-74.7%). The correlation of percent-of-predicted 6MWD with spirometry and arterial blood gas values were better than with the actual 6MWD. The percent-of-predicted 6MWD was better correlated with respiratory function than actual 6MWD for subjects using home NIV due to chronic hypercapnic respiratory failure with COPD, OHS, kyphoscoliosis, and parenchymal lung disease.

  18. Simultaneous, noninvasive, in vivo, continuous monitoring of hematocrit, vascular volume, hemoglobin oxygen saturation, pulse rate and breathing rate in humans and other animal models using a single light source

    NASA Astrophysics Data System (ADS)

    Dent, Paul; Tun, Sai Han; Fillioe, Seth; Deng, Bin; Satalin, Josh; Nieman, Gary; Wilcox, Kailyn; Searles, Quinn; Narsipur, Sri; Peterson, Charles M.; Goodisman, Jerry; Mostrom, James; Steinmann, Richard; Chaiken, J.

    2018-02-01

    We previously reported a new algorithm "PV[O]H" for continuous, noninvasive, in vivo monitoring of hematocrit changes in blood and have since shown its utility for monitoring in humans during 1) hemodialysis, 2) orthostatic perturbations and 3) during blood loss and fluid replacement in a rat model. We now show that the algorithm is sensitive to changes in hemoglobin oxygen saturation. We document the phenomenology of the effect and explain the effect using new results obtained from humans and rat models. The oxygen sensitivity derives from the differential absorption of autofluorescence originating in the static tissues by oxy and deoxy hemoglobin. Using this approach we show how to perform simultaneous, noninvasive, in vivo, continuous monitoring of hematocrit, vascular volume, hemoglobin oxygen saturation, pulse rate and breathing rate in mammals using a single light source. We suspect that monitoring of changes in this suite of vital signs can be provided with improved time response, sensitivity and precision compared to existing methodologies. Initial results also offer a more detailed glimpse into the systemic oxygen transport in the circulatory system of humans.

  19. Noninvasive diagnostic devices for diabetes through measuring tear glucose.

    PubMed

    Zhang, Jin; Hodge, William; Hutnick, Cindy; Wang, Xianbin

    2011-01-01

    This article reviews the development of a noninvasive diagnostic for diabetes by detecting ocular glucose. Early diagnosis and daily management are very important to diabetes patients to ensure a healthy life. Commercial blood glucose sensors have been used since the 1970s. Millions of diabetes patients have to prick their finger for a drop of blood 4-5 times a day to check blood glucose levels--almost 1800 times annually. There is a strong need to have a noninvasive device to help patients to manage the disease easily and painlessly. Instead of detecting the glucose in blood, monitoring the glucose level in other body fluids may provide a feasible approach for noninvasive diagnosis and diabetes control. Tear glucose has been studied for several decades. This article reviews studies on ocular glucose and its monitoring methods. Attempts to continuously monitor the concentration of tear glucose by using contact lens-based sensors are discussed as well as our current development of a nanostructured lens-based sensor for diabetes. This disposable biosensor for the detection of tear glucose may provide an alternative method to help patients manage the disease conveniently. © 2010 Diabetes Technology Society.

  20. Rheoencephalography (REG) as a Non-Invasive Monitoring Alternative for the Assessment of Brain Blood Flow

    DTIC Science & Technology

    2004-09-01

    arterial pressure of 40 mmHg, and then held there until experimental intervention, resuscitation, decompensation or death occurred. The experiment was...regulations relating to animals and experiments involving animals and adheres to principles stated in the Guide for the Care and Use of Laboratory Animals...Rheoencephalography (REG) as a Non-Invasive Monitoring Alternative for the Assessment of Brain Blood Flow P3 - 12 RTO-MP-HFM-109 experiments we

  1. Neuromuscular disease and respiratory physiology in children: putting lung function into perspective.

    PubMed

    Fauroux, Brigitte; Khirani, Sonia

    2014-08-01

    Neuromuscular diseases represent a heterogeneous group of disorders of the muscle, nerve or neuromuscular junction. The respiratory muscles are rarely spared in neuromuscular diseases even if the type of muscle involvement, severity and time course greatly varies among the different diseases. Diagnosis of respiratory muscle weakness is crucial because of the importance of respiratory morbidity and mortality. Presently, routine respiratory evaluation is based on non-invasive volitional tests, such as the measurement of lung volumes, spirometry and the maximal static pressures, which may be difficult or impossible to obtain in some young children. Other tools or parameters are thus needed to assess the respiratory muscle weakness and its consequences in young children. The measurement of oesogastric pressures can be helpful as they allow the diagnosis and quantification of paradoxical breathing, as well as the assessment of the strength of the inspiratory and expiratory muscles by means of the oesophageal pressure during a maximal sniff and of the gastric pressure during a maximal cough. Sleep assessment should also be part of the respiratory evaluation of children with neuromuscular disease with at least the recording of nocturnal gas exchange if polysomnography is not possible or unavailable. This improvement in the assessment of respiratory muscle performance may increase our understanding of the respiratory pathophysiology of the different neuromuscular diseases, improve patient care, and guide research and innovative therapies by identifying and validating respiratory parameters. © 2014 Asian Pacific Society of Respirology.

  2. SU-D-17A-07: Development and Evaluation of a Prototype Ultrasonography Respiratory Monitoring System for 4DCT Reconstruction

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yan, P; Cheng, S; Chao, C

    Purpose: Respiratory motion artifacts are commonly seen in the abdominal and thoracic CT images. A Real-time Position Management (RPM) system is integrated with CT simulator using abdominal surface as a surrogate for tracking the patient respiratory motion. The respiratory-correlated four-dimensional computed tomography (4DCT) is then reconstructed by GE advantage software. However, there are still artifacts due to inaccurate respiratory motion detecting and sorting methods. We developed an Ultrasonography Respiration Monitoring (URM) system which can directly monitor diaphragm motion to detect respiratory cycles. We also developed a new 4DCT sorting and motion estimation method to reduce the respiratory motion artifacts. Themore » new 4DCT system was compared with RPM and the GE 4DCT system. Methods: Imaging from a GE CT scanner was simultaneously correlated with both the RPM and URM to detect respiratory motion. A radiation detector, Blackcat GM-10, recorded the X-ray on/off and synchronized with URM. The diaphragm images were acquired with Ultrasonix RP system. The respiratory wave was derived from diaphragm images and synchronized with CT scanner. A more precise peaks and valleys detection tool was developed and compared with RPM. The motion is estimated for the slices which are not in the predefined respiratory phases by using block matching and optical flow method. The CT slices were then sorted into different phases and reconstructed, compared with the images reconstructed from GE Advantage software using respiratory wave produced from RPM system. Results: The 4DCT images were reconstructed for eight patients. The discontinuity at the diaphragm level due to an inaccurate identification of phases by the RPM was significantly improved by URM system. Conclusion: Our URM 4DCT system was evaluated and compared with RPM and GE 4DCT system. The new system is user friendly and able to reduce motion artifacts. It also has the potential to monitor organ motion during therapy.« less

  3. SU-E-J-211: Design and Study of In-House Software Based Respiratory Motion Monitoring, Controlling and Breath-Hold Device for Gated Radiotherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shanmugam, Senthilkumar

    Purpose: The purpose of this present work was to fabricate an in-house software based respiratory monitoring, controlling and breath-hold device using computer software programme which guides the patient to have uniform breath hold in response to request during the gated radiotherapy. Methods: The respiratory controlling device consists of a computer, inhouse software, video goggles, a highly sensitive sensor for measurement of distance, mounting systems, a camera, a respiratory signal device, a speaker and a visual indicator. The computer is used to display the respiratory movements of the patient with digital as well as analogue respiration indicators during the respiration cycle,more » to control, breath-hold and analyze the respiratory movement using indigenously developed software. Results: Studies were conducted with anthropomophic phantoms by simulating the respiratory motion on phantoms and recording the respective movements using the respiratory monitoring device. The results show good agreement between the simulated and measured movements. Further studies were conducted for 60 cancer patients with several types of cancers in the thoracic region. The respiratory movement cycles for each fraction of radiotherapy treatment were recorded and compared. Alarm indications are provided in the system to indicate when the patient breathing movement exceeds the threshold level. This will help the patient to maintain uniform breath hold during the radiotherapy treatment. Our preliminary clinical test results indicate that our device is highly reliable and able to maintain the uniform respiratory motion and breathe hold during the entire course of gated radiotherapy treatment. Conclusion: An indigenous respiratory monitoring device to guide the patient to have uniform breath hold device was fabricated. The alarm feature and the visual waveform indicator in the system guide the patient to have normal respiration. The signal from the device can be connected to the radiation unit in near future to carry out the gated radiotherapy treatment.« less

  4. Real-time tumor motion estimation using respiratory surrogate via memory-based learning

    NASA Astrophysics Data System (ADS)

    Li, Ruijiang; Lewis, John H.; Berbeco, Ross I.; Xing, Lei

    2012-08-01

    Respiratory tumor motion is a major challenge in radiation therapy for thoracic and abdominal cancers. Effective motion management requires an accurate knowledge of the real-time tumor motion. External respiration monitoring devices (optical, etc) provide a noninvasive, non-ionizing, low-cost and practical approach to obtain the respiratory signal. Due to the highly complex and nonlinear relations between tumor and surrogate motion, its ultimate success hinges on the ability to accurately infer the tumor motion from respiratory surrogates. Given their widespread use in the clinic, such a method is critically needed. We propose to use a powerful memory-based learning method to find the complex relations between tumor motion and respiratory surrogates. The method first stores the training data in memory and then finds relevant data to answer a particular query. Nearby data points are assigned high relevance (or weights) and conversely distant data are assigned low relevance. By fitting relatively simple models to local patches instead of fitting one single global model, it is able to capture highly nonlinear and complex relations between the internal tumor motion and external surrogates accurately. Due to the local nature of weighting functions, the method is inherently robust to outliers in the training data. Moreover, both training and adapting to new data are performed almost instantaneously with memory-based learning, making it suitable for dynamically following variable internal/external relations. We evaluated the method using respiratory motion data from 11 patients. The data set consists of simultaneous measurement of 3D tumor motion and 1D abdominal surface (used as the surrogate signal in this study). There are a total of 171 respiratory traces, with an average peak-to-peak amplitude of ∼15 mm and average duration of ∼115 s per trace. Given only 5 s (roughly one breath) pretreatment training data, the method achieved an average 3D error of 1.5 mm and 95th percentile error of 3.4 mm on unseen test data. The average 3D error was further reduced to 1.4 mm when the model was tuned to its optimal setting for each respiratory trace. In one trace where a few outliers are present in the training data, the proposed method achieved an error reduction of as much as ∼50% compared with the best linear model (1.0 mm versus 2.1 mm). The memory-based learning technique is able to accurately capture the highly complex and nonlinear relations between tumor and surrogate motion in an efficient manner (a few milliseconds per estimate). Furthermore, the algorithm is particularly suitable to handle situations where the training data are contaminated by large errors or outliers. These desirable properties make it an ideal candidate for accurate and robust tumor gating/tracking using respiratory surrogates.

  5. Severe respiratory failure as a presenting feature of an interstitial lung disease associated with anti-synthetase syndrome (ASS).

    PubMed

    Piroddi, Ines Maria Grazia; Ferraioli, Gianluca; Barlascini, Cornelius; Castagneto, Corrado; Nicolini, Antonello

    2016-07-01

    Anti-synthetase syndrome (ASS) is defined as a heterogeneous connective tissue disorder characterized by the association of an interstitial lung disease (ILD) with or without inflammatory myositis with the presence of anti-aminoacyl-tRNA-synthetase antibodies. ILD is one of the major extra-muscular manifestations of polymyositis and dermatomyositis. We report a case of a patient with dyspnea, cough, and intermittent fever as well as ILD associated ASS in the absence of muscular involvement. This patient was admitted to the emergency department with severe respiratory failure requiring non-invasive ventilation. Our patient's case demonstrates that the diagnosis of ASS may not be obvious. However, its diagnosis leads to appropriate and potentially life-saving treatment. Copyright © 2016 The Japanese Respiratory Society. Published by Elsevier B.V. All rights reserved.

  6. [Early exercise training after exacerbation in patients with chronic respiratory failure].

    PubMed

    Takahashi, Hiromitsu; Molleyres, Sandrine; Dousse, Nicolas; Contal, Olivier; Janssens, Jean-Paul

    2011-11-23

    Patients who suffered from an exacerbation of a chronic respiratory disorder are often very limited in terms of their exercise capacity because of severe dyspnea and amyotrophy of peripheral muscles. Early implementation of pulmonary rehabilitation may help these patients to avoid the complications of a prolonged bedridden period, and increase more rapidly their mobility. Early rehabilitation has become more frequent, but requires special skills from the care givers (chest therapists). Techniques which enhance muscular performance and motility of patients who are recovering from an exacerbation such as electromoystimulation or mobilisation under non-invasive ventilation, give encouraging results; their impact on length of hospital stay requires further studies.

  7. Early use of noninvasive techniques for clearing respiratory secretions during noninvasive positive-pressure ventilation in patients with acute exacerbation of chronic obstructive pulmonary disease and hypercapnic encephalopathy: A prospective cohort study.

    PubMed

    Wang, Jinrong; Cui, Zhaobo; Liu, Shuhong; Gao, Xiuling; Gao, Pan; Shi, Yi; Guo, Shufen; Li, Peipei

    2017-03-01

    Noninvasive positive-pressure ventilation (NPPV) might be superior to conventional mechanical ventilation (CMV) in patients with acute exacerbations of chronic obstructive pulmonary disease (AECOPDs). Inefficient clearance of respiratory secretions provokes NPPV failure in patients with hypercapnic encephalopathy (HE). This study compared CMV and NPPV combined with a noninvasive strategy for clearing secretions in HE and AECOPD patients.The present study is a prospective cohort study of AECOPD and HE patients enrolled between October 2013 and August 2015 in a critical care unit of a major university teaching hospital in China.A total of 74 patients received NPPV and 90 patients received CMV. Inclusion criteria included the following: physician-diagnosed AECOPD, spontaneous airway clearance of excessive secretions, arterial blood gas analysis requiring intensive care, moderate-to-severe dyspnea, and a Kelly-Matthay scale score of 3 to 5. Exclusion criteria included the following: preexisting psychiatric/neurological disorders unrelated to HE, upper gastrointestinal bleeding, upper airway obstruction, acute coronary syndromes, preadmission tracheostomy or endotracheal intubation, and urgent endotracheal intubation for cardiovascular, psychomotor agitation, or severe hemodynamic conditions.Intensive care unit participants were managed by NPPV. Participants received standard treatment consisting of controlled oxygen therapy during NPPV-free periods; antibiotics, intravenous doxofylline, corticosteroids (e.g., salbutamol and ambroxol), and subcutaneous low-molecular-weight heparin; and therapy for comorbidities if necessary. Nasogastric tubes were inserted only in participants who developed gastric distension. No pharmacological sedation was administered.The primary and secondary outcome measures included comparative complication rates, durations of ventilation and hospitalization, number of invasive devices/patient, and in-hospital and 1-year mortality rates.Arterial blood gases and sensorium levels improved significantly within 2 hours in the NPPV group with lower hospital mortality, fewer complications and invasive devices/patient, and superior weaning off mechanical ventilation. Mechanical ventilation duration, hospital stay, or 1-year mortality was similar between groups.NPPV combined with a noninvasive strategy to clear secretions during the first 2 hours may offer advantages over CMV in treating AECOPD patients complicated by HE.

  8. The Clinical Utilisation of Respiratory Elastance Software (CURE Soft): a bedside software for real-time respiratory mechanics monitoring and mechanical ventilation management.

    PubMed

    Szlavecz, Akos; Chiew, Yeong Shiong; Redmond, Daniel; Beatson, Alex; Glassenbury, Daniel; Corbett, Simon; Major, Vincent; Pretty, Christopher; Shaw, Geoffrey M; Benyo, Balazs; Desaive, Thomas; Chase, J Geoffrey

    2014-09-30

    Real-time patient respiratory mechanics estimation can be used to guide mechanical ventilation settings, particularly, positive end-expiratory pressure (PEEP). This work presents a software, Clinical Utilisation of Respiratory Elastance (CURE Soft), using a time-varying respiratory elastance model to offer this ability to aid in mechanical ventilation treatment. CURE Soft is a desktop application developed in JAVA. It has two modes of operation, 1) Online real-time monitoring decision support and, 2) Offline for user education purposes, auditing, or reviewing patient care. The CURE Soft has been tested in mechanically ventilated patients with respiratory failure. The clinical protocol, software testing and use of the data were approved by the New Zealand Southern Regional Ethics Committee. Using CURE Soft, patient's respiratory mechanics response to treatment and clinical protocol were monitored. Results showed that the patient's respiratory elastance (Stiffness) changed with the use of muscle relaxants, and responded differently to ventilator settings. This information can be used to guide mechanical ventilation therapy and titrate optimal ventilator PEEP. CURE Soft enables real-time calculation of model-based respiratory mechanics for mechanically ventilated patients. Results showed that the system is able to provide detailed, previously unavailable information on patient-specific respiratory mechanics and response to therapy in real-time. The additional insight available to clinicians provides the potential for improved decision-making, and thus improved patient care and outcomes.

  9. Efficacy of high-flow oxygen by nasal cannula with active humidification in a patient with acute respiratory failure of neuromuscular origin.

    PubMed

    Díaz-Lobato, Salvador; Folgado, Miguel Angel; Chapa, Angel; Mayoralas Alises, Sagrario

    2013-12-01

    The treatment of choice for patients with respiratory failure of neuromuscular origin, especially in patients with hypercapnic respiratory acidosis, is noninvasive ventilation (NIV). Endotracheal intubation and invasive ventilation are indicated for patients with severe respiratory compromise or failure of NIV. In recent years, high-flow oxygen therapy and active humidification devices have been introduced, and emerging evidence suggests that high-flow oxygen may be effective in various clinical settings, such as acute respiratory failure, after cardiac surgery, during sedation and analgesia, in acute heart failure, in hypoxemic respiratory distress, in do-not-intubate patients, in patients with chronic cough and copious secretions, pulmonary fibrosis, or cancer, in critical areas and the emergency department. We report on a patient with amyotrophic lateral sclerosis who arrived at the emergency department with acute hypercapnic respiratory failure. She did not tolerate NIV and refused intubation, but was treated successfully with heated, humidified oxygen via high-flow nasal cannula. Arterial blood analysis after an hour on high-flow nasal cannula showed improved pH, P(aCO2), and awareness. The respiratory acidosis was corrected, and she was discharged after 5 days of hospitalization. Her response to high-flow nasal cannula was similar to that expected with NIV. We discuss the mechanisms of action of heated, humidified high-flow oxygen therapy.

  10. Abnormal intra-aural pressure waves associated with death in African children with acute nontraumatic coma.

    PubMed

    Gwer, Samson; Kazungu, Michael; Chengo, Eddie; Ohuma, Eric O; Idro, Richard; Birch, Tony; Marchbanks, Robert; Kirkham, Fenella J; Newton, Charles R

    2015-07-01

    We explored the relationship between tympanic membrane displacement (TMD) measurements, a tool to monitor intracranial pressure noninvasively, and clinical features and death in children with acute coma in Kilifi, Kenya. Between November 2007 and September 2009, we made serial TMD measurements and clinical observations on children with acute coma (Blantyre coma score (BCS) ≤ 2) on the pediatric high dependency unit of Kilifi District Hospital, and on well children presenting to the hospital's outpatient department for routine follow-up. We examined middle ear function using tympanometry and measured cardiac pulse (CPA) and respiratory pulse pressure amplitudes (RPA) using the TMD analyzer. We recruited 75 children (32 (43%) females; median age 3.3 (IQR: 2.0, 4.3) years). Twenty-one (28%) children died. Higher TMD measurements predicted death. Adjusting for diagnosis, every 50 nl rise in both semirecumbent and recumbent CPA was associated with increased odds of death associated with intracranial herniation (OR: 1.61, 95% confidence interval (CI): 1.07, 2.41; P = 0.02 and OR: 1.35, 95% CI: 1.10, 1.66; P ≤ 0.01 respectively). Raised TMD pulse pressure measurements are associated with death and may be useful in detecting and monitoring risk of intracranial herniation and intracranial pressure in childhood coma.

  11. Hypoventilation improvement in an adult non-invasively ventilated patient with Rapid-onset Obesity with Hypothalamic Dysfunction Hypoventilation and Autonomic Dysregulation (ROHHAD).

    PubMed

    Graziani, Alessandro; Casalini, Pierpaolo; Mirici-Cappa, Federica; Pezzi, Giuseppe; Giuseppe Stefanini, Francesco

    2016-01-01

    Rapid-onset Obesity with Hypothalamic Dysfunction, Hypoventilation, and Autonomic Dysregulation (ROHHAD) is a rare disease of unknown etiology, characterized by rapid-onset obesity in young children, hypoventilation, hypothalamic and autonomic dysfunction. Patients between the ages of 2 and 4 present with hyperphagia and weight gain, followed by neuro-hormonal dysfunction and central hypoventilation months or years later. Cardiac arrest may represent the fatal complication of alveolar hypoventilation and early mechanical ventilation is essential for the patient's life. In this paper, we describe a 22-year-old patient with ROHHAD syndrome who had an acute respiratory failure during nocturnal non-invasive ventilation (NIV).

  12. Noninvasive Imaging of Immune Checkpoint Ligand PD-L1 in Tumors and Metastases for Guiding Immunotherapy

    PubMed Central

    Chatterjee, Samit; Lesniak, Wojciech G.

    2017-01-01

    Immunotherapy holds great promise in cancer treatment. The challenges in advancing immunotherapies lie in patient stratification and monitoring therapy. Noninvasive detection of immune checkpoint ligand PD-L1 can serve as an important biomarker for guidance and monitoring of immunotherapy. Here in, we provide an overview of our efforts to develop clinically translatable PD-L1-specific imaging agents for quantitative and real-time assessment of PD-L1 expression in tumor microenvironment. PMID:28707500

  13. Novel use of a noninvasive hemodynamic monitor in a personalized, active learning simulation.

    PubMed

    Zoller, Jonathan K; He, Jianghua; Ballew, Angela T; Orr, Walter N; Flynn, Brigid C

    2017-06-01

    The present study furthered the concept of simulation-based medical education by applying a personalized active learning component. We tested this novel approach utilizing a noninvasive hemodynamic monitor with the capability to measure and display in real time numerous hemodynamic parameters in the exercising participant. Changes in medical knowledge concerning physiology were examined with a pre-and posttest. Simply by observation of one's own hemodynamic variables, the understanding of complex physiological concepts was significantly enhanced. Copyright © 2017 the American Physiological Society.

  14. Exhaled air dispersion during noninvasive ventilation via helmets and a total facemask.

    PubMed

    Hui, David S; Chow, Benny K; Lo, Thomas; Ng, Susanna S; Ko, Fanny W; Gin, Tony; Chan, Matthew T V

    2015-05-01

    Noninvasive ventilation (NIV) via helmet or total facemask is an option for managing patients with respiratory infections in respiratory failure. However, the risk of nosocomial infection is unknown. We examined exhaled air dispersion during NIV using a human patient simulator reclined at 45° in a negative pressure room with 12 air changes/h by two different helmets via a ventilator and a total facemask via a bilevel positive airway pressure device. Exhaled air was marked by intrapulmonary smoke particles, illuminated by laser light sheet, and captured by a video camera for data analysis. Significant exposure was defined as where there was ≥ 20% of normalized smoke concentration. During NIV via a helmet with the simulator programmed in mild lung injury, exhaled air leaked through the neck-helmet interface with a radial distance of 150 to 230 mm when inspiratory positive airway pressure was increased from 12 to 20 cm H2O, respectively, while keeping the expiratory pressure at 10 cm H2O. During NIV via a helmet with air cushion around the neck, there was negligible air leakage. During NIV via a total facemask for mild lung injury, air leaked through the exhalation port to 618 and 812 mm when inspiratory pressure was increased from 10 to 18 cm H2O, respectively, with the expiratory pressure at 5 cm H2O. A helmet with a good seal around the neck is needed to prevent nosocomial infection during NIV for patients with respiratory infections.

  15. A new horizon for the use of non-invasive ventilation in patients with acute respiratory distress syndrome.

    PubMed

    Carron, Michele

    2016-09-01

    Non-invasive ventilation (NIV) has assumed an important role in the management of acute respiratory failure (ARF). NIV, compared with standard medical therapy, improves survival and reduces complications in selected patients with ARF. NIV represents the first-line intervention for some forms of ARF, such as chronic obstructive pulmonary disease (COPD) exacerbations and acute cardiogenic pulmonary edema. The use of NIV is also well supported for immunocompromised patients who are at high risk for infectious complications from endotracheal intubation. Selection of appropriate patients is crucial for optimizing NIV success rates. Appropriate ventilator settings, a well-fitting and comfortable interface, and a team skilled and experienced in managing NIV are key components to its success. In a recent issue of the Journal of the American Medical Association , Patel et al . reported the results of their single-center trial of 83 patients with acute respiratory distress syndrome (ARDS) who were randomly assigned to NIV delivered via a helmet or face mask. Patients assigned to the helmet group exhibited a significantly lower intubation rate and were more likely to survive through 90 days. This perspective reviews the findings of this trial in the context of current clinical practice and in light of data from the literature focused on the potential reasons for success of NIV delivered through a helmet compared to face mask. The implications for early management of patients with ARDS are likewise discussed.

  16. [Sleep-apnea syndrome, mechanical ventilation and critical care in Archivos de Bronconeumología (December 2009-December 2010)].

    PubMed

    Abad Fernández, Araceli; Pumarega, Irene Cano; Hernández, Concepción; Sampol, Gabriel; Terán-Santos, Joaquín

    2011-01-01

    The present study aims to review all the major articles on respiratory sleep disorders, mechanical ventilation, and respiratory critical care published in the last year in Archivos de bronconeumología. Between December 2009 and November 2010, 15 studies on these topics were published in Archivos de bronconeumología. Ten of these studies dealt with respiratory sleep disorders, consisting of six original articles, one special article, one review article, one letter to the editor and one supplement on chronic obstructive pulmonary disease and its association with sleep apneas. Five articles were published on non-invasive mechanical ventilation: one editorial, one special article, one article in a supplement and two original articles. As in previous years, there was a marked difference in the number of articles published on non-invasive mechanical ventilation and sleep-apnea syndrome, with a greater number of articles being published on the latter. Although some articles highlight the importance of the place where ventilation is commenced, no study specifically dealing with intermediate care units was published in Archivos de bronconeumología in 2010. This absence could be interpreted as a result of the low implantation of this type of unit in Spain, contrasting with the high activity undertaken in this field by pneumology services. Copyright © 2011 Sociedad Española de Neumología y Cirugía Torácica. Published by Elsevier Espana. All rights reserved.

  17. Smart textile for respiratory monitoring and thoraco-abdominal motion pattern evaluation.

    PubMed

    Massaroni, Carlo; Venanzi, Cecilia; Silvatti, Amanda P; Lo Presti, Daniela; Saccomandi, Paola; Formica, Domenico; Giurazza, Francesco; Caponero, Michele A; Schena, Emiliano

    2018-05-01

    The use of wearable systems for monitoring vital parameters has gained wide popularity in several medical fields. The focus of the present study is the experimental assessment of a smart textile based on 12 fiber Bragg grating sensors for breathing monitoring and thoraco-abdominal motion pattern analysis. The feasibility of the smart textile for monitoring several temporal respiratory parameters (ie, breath-by-breath respiratory period, breathing frequency, duration of inspiratory and expiratory phases), volume variations of the whole chest wall and of its compartments is performed on 8 healthy male volunteers. Values gathered by the textile are compared to the data obtained by a motion analysis system, used as the reference instrument. Good agreement between the 2 systems on both respiratory period (bias of 0.01 seconds), breathing frequency (bias of -0.02 breaths/min) and tidal volume (bias of 0.09 L) values is demonstrated. Smart textile shows good performance in the monitoring of thoraco-abdominal pattern and its variation, as well. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. Noninvasive, three-dimensional full-field body sensor for surface deformation monitoring of human body in vivo

    NASA Astrophysics Data System (ADS)

    Chen, Zhenning; Shao, Xinxing; He, Xiaoyuan; Wu, Jialin; Xu, Xiangyang; Zhang, Jinlin

    2017-09-01

    Noninvasive, three-dimensional (3-D), full-field surface deformation measurements of the human body are important for biomedical investigations. We proposed a 3-D noninvasive, full-field body sensor based on stereo digital image correlation (stereo-DIC) for surface deformation monitoring of the human body in vivo. First, by applying an improved water-transfer printing (WTP) technique to transfer optimized speckle patterns onto the skin, the body sensor was conveniently and harmlessly fabricated directly onto the human body. Then, stereo-DIC was used to achieve 3-D noncontact and noninvasive surface deformation measurements. The accuracy and efficiency of the proposed body sensor were verified and discussed by considering different complexions. Moreover, the fabrication of speckle patterns on human skin, which has always been considered a challenging problem, was shown to be feasible, effective, and harmless as a result of the improved WTP technique. An application of the proposed stereo-DIC-based body sensor was demonstrated by measuring the pulse wave velocity of human carotid artery.

  19. Intracranial Pressure Monitoring: Invasive versus Non-Invasive Methods—A Review

    PubMed Central

    Raboel, P. H.; Bartek, J.; Andresen, M.; Bellander, B. M.; Romner, B.

    2012-01-01

    Monitoring of intracranial pressure (ICP) has been used for decades in the fields of neurosurgery and neurology. There are multiple techniques: invasive as well as noninvasive. This paper aims to provide an overview of the advantages and disadvantages of the most common and well-known methods as well as assess whether noninvasive techniques (transcranial Doppler, tympanic membrane displacement, optic nerve sheath diameter, CT scan/MRI and fundoscopy) can be used as reliable alternatives to the invasive techniques (ventriculostomy and microtransducers). Ventriculostomy is considered the gold standard in terms of accurate measurement of pressure, although microtransducers generally are just as accurate. Both invasive techniques are associated with a minor risk of complications such as hemorrhage and infection. Furthermore, zero drift is a problem with selected microtransducers. The non-invasive techniques are without the invasive methods' risk of complication, but fail to measure ICP accurately enough to be used as routine alternatives to invasive measurement. We conclude that invasive measurement is currently the only option for accurate measurement of ICP. PMID:22720148

  20. Non-invasive acoustic-based monitoring of uranium in solution and H/D ratio

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pantea, Cristian; Beedle, Christopher Craig; Sinha, Dipen N.

    The primary objective of this project is to adapt existing non-invasive acoustic techniques (Swept-Frequency Acoustic Interferometry and Gaussian-pulse acoustic technique) for the purpose of demonstrating the ability to quantify U or H/D ratios in solution. Furthermore, a successful demonstration will provide an easily implemented, low cost, and non-invasive method for remote and unattended uranium mass measurements for International Atomic Energy Agency (IAEA).

  1. The use of non-invasive fetal electrocardiography in diagnosing second-degree fetal atrioventricular block.

    PubMed

    Lakhno, Igor; Behar, Joachim A; Oster, Julien; Shulgin, Vyacheslav; Ostras, Oleksii; Andreotti, Fernando

    2017-01-01

    Complete atrioventricular block in fetuses is known to be mostly associated with autoimmune disease and can be irreversible if no steroids treatment is provided. Conventional methods used in clinical practice for diagnosing fetal arrhythmia are limited since they do not reflect the primary electrophysiological conduction processes that take place in the myocardium. The non-invasive fetal electrocardiogram has the potential to better support fetal arrhythmias diagnosis through the continuous analysis of the beat to beat variation of the fetal heart rate and morphological analysis of the PQRST complex. We present two retrospective case reports on which atrioventricular block diagnosis could have been supported by the non-invasive fetal electrocardiogram. The two cases comprised a 22-year-old pregnant woman with the gestational age of 31 weeks and a 25-year-old pregnant woman with the gestational age of 41 weeks. Both women were admitted to the Department of Maternal and Fetal Medicine at the Kyiv and Kharkiv municipal perinatal clinics. Patients were observed using standard fetal monitoring methods as well as the non-invasive fetal electrocardiogram. The non-invasive fetal electrocardiographic recordings were analyzed retrospectively, where it is possible to identify the presence of the atrioventricular block. This study demonstrates, for the first time, the feasibility of the non-invasive fetal electrocardiogram as a supplementary method to diagnose of the fetal atrioventricular block. Combined with current fetal monitoring techniques, non-invasive fetal electrocardiography could support clinical decisions.

  2. Noninvasive monitoring of photodynamic therapy on skin neoplastic lesions using the optical attenuation coefficient measured by optical coherence tomography

    NASA Astrophysics Data System (ADS)

    Goulart, Viviane P.; dos Santos, Moisés O.; Latrive, Anne; Freitas, Anderson Z.; Correa, Luciana; Zezell, Denise M.

    2015-05-01

    Photodynamic therapy (PDT) has become a promising alternative for treatment of skin lesions such as squamous cell carcinoma. We propose a method to monitor the effects of PDT in a noninvasive way by using the optical attenuation coefficient (OAC) calculated from optical coherence tomography (OCT) images. We conducted a study on mice with chemically induced neoplastic lesions and performed PDT on these lesions using homemade photosensitizers. The response of neoplastic lesions to therapy was monitored using, at the same time, macroscopic clinical visualization, histopathological analysis, OCT imaging, and OCT-based attenuation coefficient measurement. Results with all four modalities demonstrated a positive response to treatment. The attenuation coefficient was found to be 1.4 higher in skin lesions than in healthy tissue and it decreased after therapy. This study shows that the OAC is a potential tool to noninvasively assess the evolution of skin neoplastic lesions with time after treatment.

  3. Pulsed Phase Lock Loop Device for Monitoring Intracranial Pressure During Space Flight

    NASA Technical Reports Server (NTRS)

    Ueno, Toshiaki; Macias, Brandon R.; Yost, William T.; Hargens, Alan R.

    2003-01-01

    We have developed an ultrasonic device to monitor ICP waveforms non-invasively from cranial diameter oscillations using a NASA-developed pulsed phase lock loop (PPLL) technique. The purpose of this study was to attempt to validate the PPLL device for reliable recordings of ICP waveforms and analysis of ICP dynamics in vivo. METHODS: PPLL outputs were recorded in patients during invasive ICP monitoring at UCSD Medical Center (n=10). RESULTS: An averaged linear regression coefficient between ICP and PPLL waveform data during one cardiac cycle in all patients is 0.88 +/- 0.02 (mean +/- SE). Coherence function analysis indicated that ICP and PPLL waveforms have high correlation in the lst, 2nd, and 3rd harmonic waves associated with a cardiac cycle. CONCLUSIONS: PPLL outputs represent ICP waveforms in both frequency and time domains. PPLL technology enables in vivo evaluation of ICP dynamics non-invasively, and can acquire continuous ICP waveforms during spaceflight because of compactness and non-invasive nature.

  4. Design of a novel noninvasive spectrometer for pesticide residues monitor

    NASA Astrophysics Data System (ADS)

    Ren, Zhong; Liu, Guodong; Huang, Zhen

    2014-11-01

    Although the gas or liquid chromatography had been widely used into pesticide residues monitoring, some drawbacks such as time-consuming, complicated operation and especially the destructivity for samples were existed. To overcome the limits of destructive detection methods, the noninvasive detection method based on spectroscopy was used to detect the pesticide residues in this paper. To overcome low resolution and light-efficiency due to the drawbacks of the classical plane and holography concave gratings, a novel noninvasive spectrometer for pesticide residues monitor (PRM) based on volume holography transmission (VHT) grating was designed. Meanwhile, a custom-built splitting light system for PRM based on the VHT grating was developed. In addition, the linear charge coupled device (CCD) with combined data acquisition (DAQ) card and the virtual-PRM based on LabVIEW were respectively used as the spectral acquisition hardware and software-platform. Experimental results showed that the spectral resolution of this spectrometer reached 2nm, and the VHT grating's diffraction efficiency was gotten via the simulation experiment.

  5. In vivo noninvasive measurement of preprandial and postprandial blood glucose using optical coherence tomography

    NASA Astrophysics Data System (ADS)

    Zhang, Ying; Zhang, Xiyang; Li, Zhifang; Li, Hui

    2016-10-01

    Blood glucose concentration measurement is essential for the diagnosis and treatment of diabetes. However, conventional glucose measurement methods are invasive and not suitable for real-time monitoring. This study demonstrated a noninvasive blood glucose measurement method using optical coherence tomography to image human lip in vivo. Optical coherence tomography (OCT) is a noninvasive and depth-resolved technique capable of acquiring tissue structure images in real time. Human lip has very thin skin and is full of blood vessels, which is appropriate for noninvasive glucose measurement. To verify the feasibility of OCT for glucose concentration monitoring, two groups of OCT imaging data were obtained from human lips of normal people. In one group, OCT images of lip were acquired from people on an empty stomach. In the other group, the same sites of lip were observed by OCT 2 hours after breakfast. Evident differences were found from two groups of OCT images that correspond to preprandial glucose and 2- hour postprandial glucose, respectively. The relationship between OCT image and blood glucose concentration was investigated. The result indicates that OCT possesses considerable prospects in terms of noninvasive blood glucose measurement.

  6. Multi-parameter vital sign database to assist in alarm optimization for general care units.

    PubMed

    Welch, James; Kanter, Benjamin; Skora, Brooke; McCombie, Scott; Henry, Isaac; McCombie, Devin; Kennedy, Rosemary; Soller, Babs

    2016-12-01

    Continual vital sign assessment on the general care, medical-surgical floor is expected to provide early indication of patient deterioration and increase the effectiveness of rapid response teams. However, there is concern that continual, multi-parameter vital sign monitoring will produce alarm fatigue. The objective of this study was the development of a methodology to help care teams optimize alarm settings. An on-body wireless monitoring system was used to continually assess heart rate, respiratory rate, SpO 2 and noninvasive blood pressure in the general ward of ten hospitals between April 1, 2014 and January 19, 2015. These data, 94,575 h for 3430 patients are contained in a large database, accessible with cloud computing tools. Simulation scenarios assessed the total alarm rate as a function of threshold and annunciation delay (s). The total alarm rate of ten alarms/patient/day predicted from the cloud-hosted database was the same as the total alarm rate for a 10 day evaluation (1550 h for 36 patients) in an independent hospital. Plots of vital sign distributions in the cloud-hosted database were similar to other large databases published by different authors. The cloud-hosted database can be used to run simulations for various alarm thresholds and annunciation delays to predict the total alarm burden experienced by nursing staff. This methodology might, in the future, be used to help reduce alarm fatigue without sacrificing the ability to continually monitor all vital signs.

  7. Pulmonary function in obese vs non-obese cats.

    PubMed

    García-Guasch, Laín; Caro-Vadillo, Alicia; Manubens-Grau, Jordi; Carretón, Elena; Camacho, Aparecido A; Montoya-Alonso, José Alberto

    2015-06-01

    Obesity is a risk factor in the development of several respiratory diseases. Lung volumes tend to be decreased, especially expiratory reserve volume, increasing expiratory flow limitation during tidal breathing. Barometric whole-body plethysmography is a non-invasive pulmonary function test that allows a dynamic study of breathing patterns. The objective of this study was to compare pulmonary function variables between obese and non-obese cats through the use of barometric whole-body plethysmography. Nine normal-weight and six obese cats were placed in the plethysmograph chamber, and different respiratory variables were measured. There was a significant decrease in tidal volume per kilogram (P = 0.003), minute volume per kilogram (P = 0.001) and peak inspiratory and expiratory flows per kilogram (P = 0.001) in obese cats compared with non-obese cats. Obesity failed to demonstrate a significant increase in bronchoconstriction index variable enhanced pause (Penh), as previously reported in humans and dogs. The results show that feline obesity impairs pulmonary function in cats, although a significant increase in bronchoconstriction indexes was not observed. Non-invasive barometric whole-body plethysmography can help characterise mechanical dysfunction of the airways in obese cats. © ISFM and AAFP 2014.

  8. Resource utilization patterns using non-invasive ventilation in neonates with respiratory distress syndrome.

    PubMed

    Chavez, Thomas A; Lakshmanan, Ashwini; Figueroa, Lizzette; Iyer, Narayan; Stavroudis, Theodora A; Garingo, Arlene; Friedlich, Philippe S; Ramanathan, Rangasamy

    2018-05-24

    To describe the frequency of non-invasive ventilation (NIV) and endotracheal intubation use in neonates diagnosed with respiratory distress syndrome (RDS); to describe resources utilization (length of stay (LOS), charges, costs) among NIV and intubated RDS groups. Retrospective study from the national Kid's Inpatient Database of the Healthcare Cost and Utilization Project, for the years 1997-2012. Propensity scoring and multivariate regression analysis used to describe differences. A total of 595,254 out of 42,912,090 cases were identified with RDS. There was an increase in NIV use from 6% in 1997 to 17% in 2012. After matching, patients receiving NIV only were associated with shorter LOS: (95%CI) 25 (25.3,25.7) vs. 35 (34.2,34.9) days, decreased costs: ($/1k) 46.1 (45.5,46.8) vs. 65.0 (64.1,66.0), decreased charges: 130.3 (128.6,132.1) vs. 192.1 (189.5,194.6) compared to intubated neonates. There was a three-fold increase in NIV use within the 15-year study period. NIV use was associated with decreased LOS, charges and costs compared to intubated patients.

  9. Non-invasive ventilation in amyotrophic lateral sclerosis: a 10 year population based study.

    PubMed

    Chiò, Adriano; Calvo, Andrea; Moglia, Cristina; Gamna, Federica; Mattei, Alessio; Mazzini, Letizia; Mora, Gabriele

    2012-04-01

    To evaluate the clinical characteristics and outcome of non-invasive ventilation (NIV) in an epidemiological based series of amyotrophic lateral sclerosis (ALS) patients. The study was performed using data from the Piemonte and Valle d'Aosta Register for ALS, a prospective epidemiological register enrolling all ALS incident cases in two Italian regions. Among the 1260 patients incident in the period 1995-2004, 259 (20.6%) underwent NIV. Young male patients and subjects attending the tertiary ALS centres were more likely to undergo NIV. There was a progressive significant increase in the use of NIV during the study but was limited to patients attending the ALS tertiary centres. Median survival after NIV was 289 days (95% CI 255 to 333). In an epidemiological setting, NIV represents an increasingly utilised option for the treatment of respiratory disturbances in ALS and has favourable effects on survival, in particular among patients followed by tertiary ALS centres. Sociocultural factors, such as age, gender and marital status, strongly influence the probability of undergoing NIV. Efforts should be made to remove these obstacles in order to spread the use of NIV in all ALS patients with respiratory failure.

  10. Evaluation of Heat Flux Measurement as a New Process Analytical Technology Monitoring Tool in Freeze Drying.

    PubMed

    Vollrath, Ilona; Pauli, Victoria; Friess, Wolfgang; Freitag, Angelika; Hawe, Andrea; Winter, Gerhard

    2017-05-01

    This study investigates the suitability of heat flux measurement as a new technique for monitoring product temperature and critical end points during freeze drying. The heat flux sensor is tightly mounted on the shelf and measures non-invasively (no contact with the product) the heat transferred from shelf to vial. Heat flux data were compared to comparative pressure measurement, thermocouple readings, and Karl Fischer titration as current state of the art monitoring techniques. The whole freeze drying process including freezing (both by ramp freezing and controlled nucleation) and primary and secondary drying was considered. We found that direct measurement of the transferred heat enables more insights into thermodynamics of the freezing process. Furthermore, a vial heat transfer coefficient can be calculated from heat flux data, which ultimately provides a non-invasive method to monitor product temperature throughout primary drying. The end point of primary drying determined by heat flux measurements was in accordance with the one defined by thermocouples. During secondary drying, heat flux measurements could not indicate the progress of drying as monitoring the residual moisture content. In conclusion, heat flux measurements are a promising new non-invasive tool for lyophilization process monitoring and development using energy transfer as a control parameter. Copyright © 2017 American Pharmacists Association®. Published by Elsevier Inc. All rights reserved.

  11. A technology roadmap of smart biosensors from conventional glucose monitoring systems.

    PubMed

    Shende, Pravin; Sahu, Pratiksha; Gaud, Ram

    2017-06-01

    The objective of this review article is to focus on technology roadmap of smart biosensors from a conventional glucose monitoring system. The estimation of glucose with commercially available devices involves analysis of blood samples that are obtained by pricking finger or extracting blood from the forearm. Since pain and discomfort are associated with invasive methods, the non-invasive measurement techniques have been investigated. The non-invasive methods show advantages like non-exposure to sharp objects such as needles and syringes, due to which there is an increase in testing frequency, improved control of glucose concentration and absence of pain and biohazard materials. This review study is aimed to describe recent invasive techniques and major noninvasive techniques, viz. biosensors, optical techniques and sensor-embedded contact lenses for glucose estimation.

  12. Monitoring of tissue optical properties using OCT: application for blood glucose analysis

    NASA Astrophysics Data System (ADS)

    Larin, Kirill V.; Eledrisi, Mohsen S.; Ashitkov, Taras V.; Motamedi, Massoud; Esenaliev, Rinat O.

    2002-07-01

    Noninvasive monitoring of tissue optical properties in real time could significantly improve diagnostics and management of various diseases. Recently we proposed to use high- resolution Optical Coherence Tomography (OCT) technique for measurement of tissue scattering coefficient at the depth of up to 1mm. Our pilot studies performed in vitro and in vivo demonstrated that measurement of tissue scattering with this technique can potentially be applied for noninvasive monitoring of blood glucose concentration. High resolution and coherent photon detection of the OCT technique allowed detection of glucose-induced changes in the scattering coefficient. In this paper we report results of in vivo studies performed in dog, New Zealand rabbits, and first human subjects. OCT system with the wavelength of 1300 nm was used in our experiments. OCT signal slope was measured and compared with actual blood glucose concentration. Bolus glucose injections and glucose clamping administrations were used in animal studies. OCT signals were recorded form human subjects during oral glucose tolerance test. Results obtained form both animal and human studies show good correlation between slope of the OCT signals and actual blood glucose concentration measured using standard glucometesr. Sensitivity and accuracy of blood glucose concentrations monitoring with the OCT is discussed. Obtained result suggest that OCT is a promising technique for noninvasive monitoring of tissue analytes including glucose.

  13. Magnetic resonance imaging and transient elastography in the management of Nonalcoholic Fatty Liver Disease (NAFLD).

    PubMed

    Han, Ma Ai Thanda; Saouaf, Rola; Ayoub, Walid; Todo, Tsuyoshi; Mena, Edward; Noureddin, Mazen

    2017-04-01

    Nonalcoholic fatty liver disease (NAFLD) is the most common cause of chronic liver disease and cirrhosis worldwide and the second most common cause of liver transplantation in major medical centers. Because liver steatosis and fibrosis severity are related to disease morbidity and mortality, the extent of disease, and disease progression, they need to be assessed and monitored. In addition, innovation with new drug developments requires disease staging and monitoring in both phase 2 and 3 clinical trials. Currently, disease assessment in both clinical practice and research is mostly performed by liver biopsy, an invasive, procedure with risks. Noninvasive, highly accurate tests are needed that could be used in clinical trials as surrogate endpoints and in clinical practice for monitoring patients. Area Covered: We discuss noninvasive tests, transient elastography (TE) with controlled attenuation parameter (CAP), magnetic resonance imaging (MRI), and MR elastography (MRE), summarize the available evidence of their usefulness for assessing steatosis and fibrosis. Therefore they could be used as clinical trials outcomes and in disease monitoring in clinical practice. Expert Commentary: TE with CAP, MRI and MRE are highly accurate noninvasive diagnostic tools for quantifying hepatic steatosis and fibrosis. Therefore they could be used as clinical trials outcomes and in disease monitoring in clinical practice.

  14. Real-time non-invasive eyetracking and gaze-point determination for human-computer interaction and biomedicine

    NASA Technical Reports Server (NTRS)

    Talukder, Ashit; Morookian, John-Michael; Monacos, S.; Lam, R.; Lebaw, C.; Bond, A.

    2004-01-01

    Eyetracking is one of the latest technologies that has shown potential in several areas including human-computer interaction for people with and without disabilities, and for noninvasive monitoring, detection, and even diagnosis of physiological and neurological problems in individuals.

  15. 21 CFR 868.2480 - Cutaneous carbon dioxide (PcCO2) monitor.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Cutaneous carbon dioxide (PcCO2) monitor. 868.2480... (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Monitoring Devices § 868.2480 Cutaneous carbon dioxide (PcCO2) monitor. (a) Identification. A cutaneous carbon dioxide (PcCO2) monitor is a noninvasive heated...

  16. Development of a robust and cost-effective 3D respiratory motion monitoring system using the kinect device: Accuracy comparison with the conventional stereovision navigation system.

    PubMed

    Bae, Myungsoo; Lee, Sangmin; Kim, Namkug

    2018-07-01

    To develop and validate a robust and cost-effective 3D respiratory monitoring system based on a Kinect device with a custom-made simple marker. A 3D respiratory monitoring system comprising the simple marker and the Microsoft Kinect v2 device was developed. The marker was designed for simple and robust detection, and the tracking algorithm was developed using the depth, RGB, and infra-red images acquired from the Kinect sensor. A Kalman filter was used to suppress movement noises. The major movements of the marker attached to the four different locations of body surface were determined from the initially collected tracking points of the marker while breathing. The signal level of respiratory motion with the tracking point was estimated along the major direction vector. The accuracy of the results was evaluated through a comparison with those of the conventional stereovision navigation system (NDI Polaris Spectra). Sixteen normal volunteers were enrolled to evaluate the accuracy of this system. The correlation coefficients between the respiratory motion signal from the Kinect device and conventional navigation system ranged from 0.970 to 0.999 and from 0.837 to 0.995 at the abdominal and thoracic surfaces, respectively. The respiratory motion signal from this system was obtained at 27-30 frames/s. This system with the Kinect v2 device and simple marker could be used for cost-effective, robust and accurate 3D respiratory motion monitoring. In addition, this system is as reliable for respiratory motion signal generation and as practically useful as the conventional stereovision navigation system and is less sensitive to patient posture. Copyright © 2018 Elsevier B.V. All rights reserved.

  17. Respiratory flow-sound relationship during both wakefulness and sleep and its variation in relation to sleep apnea.

    PubMed

    Yadollahi, Azadeh; Montazeri, Aman; Azarbarzin, Ali; Moussavi, Zahra

    2013-03-01

    Tracheal respiratory sound analysis is a simple and non-invasive way to study the pathophysiology of the upper airway and has recently been used for acoustic estimation of respiratory flow and sleep apnea diagnosis. However in none of the previous studies was the respiratory flow-sound relationship studied in people with obstructive sleep apnea (OSA), nor during sleep. In this study, we recorded tracheal sound, respiratory flow, and head position from eight non-OSA and 10 OSA individuals during sleep and wakefulness. We compared the flow-sound relationship and variations in model parameters from wakefulness to sleep within and between the two groups. The results show that during both wakefulness and sleep, flow-sound relationship follows a power law but with different parameters. Furthermore, the variations in model parameters may be representative of the OSA pathology. The other objective of this study was to examine the accuracy of respiratory flow estimation algorithms during sleep: we investigated two approaches for calibrating the model parameters using the known data recorded during either wakefulness or sleep. The results show that the acoustical respiratory flow estimation parameters change from wakefulness to sleep. Therefore, if the model is calibrated using wakefulness data, although the estimated respiratory flow follows the relative variations of the real flow, the quantitative flow estimation error would be high during sleep. On the other hand, when the calibration parameters are extracted from tracheal sound and respiratory flow recordings during sleep, the respiratory flow estimation error is less than 10%.

  18. The feasibility of the auto tuning respiratory compensation system with ultrasonic image tracking technique.

    PubMed

    Chuang, Ho-Chiao; Hsu, Hsiao-Yu; Nieh, Shu-Kan; Tien, Der-Chi

    2015-01-01

    The purpose of this study is to assess the feasibility of using the analytical technique of ultrasound images in combination with an auto tumor localization system. During respiration, the activity of breathing in and out causes organs displacement at the lower lobe of the lung, and the maximum displacement range happens in the Superior-Inferior (SI) direction. Therefore, in this study all the tumor positioning is in SI direction under respiratory compensation, in which the compensations are carried out to the organs at the lower lobe and adjacent to the lower lobe of lung.In this research, due to the processes of ultrasound imaging generation, image analysis and signal transmission, when the captured respiratory signals are sent to auto tumor localization system, there was a signal time delay. The total delay time of the entire signal transmission process was 0.254 ± 0.023 seconds (with the lowest standard deviation) after implementing a series of analyses. To compensate for this signal delay time (0.254 ± 0.023 sec), a phase lead compensator (PLC) was designed and built into the auto tumor localization system. By analyzing the impact of the delay time and the respiratory waveforms under different frequencies on the phase lead compensator, an overall system delay time can be configured. Results showed as the respiratory frequency increased, variable value ``a'' and the subsequent gain ``k'' in the controller becomes larger. Moreover, value ``a'' and ``k'' increased as the system delay time increased when the respiratory frequency was fixed. The relationship of value ``a'' and ``k'' to the respiratory frequency can be obtained by using the curve fitting method to compensate for the respiratory motion for tumor localization. Through the comparison of the uncompensated signal and the compensated signal performed by the auto tumor localization system on the simulated respiratory signal, the feasibility of using ultrasound image analysis technology combined with the developed auto tumor localization system can be evaluated. The results show that the simulated respiratory signals under different frequencies of 0.5, 0.333, 0.25, 0.2 and 0.167 Hz with phase lead compensators were improved and stabilized. The compensation rate increased to the range of 7.04$∼ $18.82%, and the final compensation rate is about 97%. Therefore the auto tumor localization system combined with the ultrasound image analysis techniques is feasible.In this study, the developed ultrasound image analysis techniques combined into the auto tumor localization system has the following four advantages: (1) It is a non-invasive way (ultrasonic images) to monitor the entire compensating process of the active respiration instead of using a C-arm (invasive) to observe the organs motion. (2) During radiation therapy, the whole treatment process can be continuous, which can save the overall treatment time. (3) It is an independent system, which can be mounted onto any treatment couch. (4) Users can operate this system easily without the need of prior complicated training process.

  19. Non-Invasive Detection of Lung Inflammation by Near-Infrared Fluorescence Imaging Using Bimodal Liposomes.

    PubMed

    Desu, Hari R; Wood, George C; Thoma, Laura A

    2016-01-01

    Acute lung injury (ALI) and its more severe form, acute respiratory distress syndrome results in respiratory obstruction and severe lung inflammation. Critical characteristics of ALI are alveolar edema, infiltration of leukocytes (neutrophils and monocytes), release of pro-inflammatory cytokines and chemokines into broncho-alveolar lavage fluid, and activation of integrin receptors. The purpose of the study was to demonstrate non-invasive detection of lung inflammation using integrin receptor targeted fluorescence liposomes. An inflammation similar to that observed in ALI was elicited in rodents by intra-tracheal instillation of interleukin-1beta (IL-1beta). Cyclic arginine glycine-(D)-aspartic acid-peptide (cRGD-peptide) grafted fluorescence liposomes were administered to ALI induced male Sprague-Dawley rats for targeting lung integrin receptors. Near-infrared fluorescence imaging (NIRFI) was applied for visualization and quantitation of lung inflammation. NIRFI signals were correlated with inflammatory cellular and biochemical markers of lungs. A positive correlation was observed between NIRF signals and lung inflammation markers. Compared to control group, an intense NIRF signal was observed in ALI induced rats in the window 6-24 h post-IL-1beta instillation. Interaction of integrin receptors with targeted liposomes was assumed to contribute to intense NIRF signal. RT-PCR studies showed an elevated lung expression of alphavbeta5 integrin receptors, 12 h post-IL-1beta instillation. In vitro studies demonstrated integrin receptor specificity of targeted liposomes. These targeted liposomes showed binding to alphavbeta5 integrin receptors expressed on alveolar cells. Non-invasive detection of lung inflammation was demonstrated using a combination of integrin receptor targeting and NIRFI.

  20. Electrical impedance tomography.

    PubMed

    Costa, Eduardo L V; Lima, Raul Gonzalez; Amato, Marcelo B P

    2009-02-01

    Electrical impedance tomography (EIT) is a noninvasive, radiation-free monitoring tool that allows real-time imaging of ventilation. The purpose of this article is to discuss the fundamentals of EIT and to review the use of EIT in critical care patients. In addition to its established role in describing the distribution of alveolar ventilation, EIT has been shown to be a useful tool to detect lung collapse and monitor lung recruitment, both regionally and on a global basis. EIT has also been used to diagnose with high sensitivity incident pneumothoraces during mechanical ventilation. Additionally, with injection of hypertonic saline as a contrast agent, it is possible to estimate ventilation/perfusion distributions. EIT is cheap, noninvasive and allows continuous monitoring of ventilation. It is gaining acceptance as a valuable monitoring tool for the care of critical patients.

  1. Quantifying lung morphology with respiratory-gated micro-CT in a murine model of emphysema

    NASA Astrophysics Data System (ADS)

    Ford, N. L.; Martin, E. L.; Lewis, J. F.; Veldhuizen, R. A. W.; Holdsworth, D. W.; Drangova, M.

    2009-04-01

    Non-invasive micro-CT imaging techniques have been developed to investigate lung structure in free-breathing rodents. In this study, we investigate the utility of retrospectively respiratory-gated micro-CT imaging in an emphysema model to determine if anatomical changes could be observed in the image-derived quantitative analysis at two respiratory phases. The emphysema model chosen was a well-characterized, genetically altered model (TIMP-3 knockout mice) that exhibits a homogeneous phenotype. Micro-CT scans of the free-breathing, anaesthetized mice were obtained in 50 s and retrospectively respiratory sorted and reconstructed, providing 3D images representing peak inspiration and end expiration with 0.15 mm isotropic voxel spacing. Anatomical measurements included the volume and CT density of the lungs and the volume of the major airways, along with the diameters of the trachea, left bronchus and right bronchus. From these measurements, functional parameters such as functional residual capacity and tidal volume were calculated. Significant differences between the wild-type and TIMP-3 knockout groups were observed for measurements of CT density over the entire lung, indicating increased air content in the lungs of TIMP-3 knockout mice. These results demonstrate retrospective respiratory-gated micro-CT, providing images at multiple respiratory phases that can be analyzed quantitatively to investigate anatomical changes in murine models of emphysema.

  2. Hypnosis in paediatric respiratory medicine.

    PubMed

    McBride, Joshua J; Vlieger, Arine M; Anbar, Ran D

    2014-03-01

    Hypnotherapy is an often misunderstood yet effective therapy. It has been reported to be useful within the field of paediatric respiratory medicine as both a primary and an adjunctive therapy. This article gives a brief overview of how hypnotherapy is performed followed by a review of its applications in paediatric patients with asthma, cystic fibrosis, dyspnea, habit cough, vocal cord dysfunction, and those requiring non-invasive positive pressure ventilation. As the available literature is comprised mostly of case series, retrospective studies, and only a single small randomized study, the field would be strengthened by additional randomized, controlled trials in order to better establish the effectiveness of hypnosis as a treatment, and to identify the processes leading to hypnosis-induced physiologic changes. As examples of the utility of hypnosis and how it can be taught to children with respiratory disease, the article includes videos that demonstrate its use for patients with cystic fibrosis. Copyright © 2013 Elsevier Ltd. All rights reserved.

  3. Chronic obstructive pulmonary disease and sleep related disorders.

    PubMed

    Tsai, Sheila C

    2017-03-01

    Sleep related disorders are common and under-recognized in the chronic obstructive pulmonary disease (COPD) population. COPD symptoms can disrupt sleep. Similarly, sleep disorders can affect COPD. This review highlights the common sleep disorders seen in COPD patients, their impact, and potential management. Treatment of sleep disorders may improve quality of life in COPD patients. Optimizing inhaler therapy improves sleep quality. Increased inflammatory markers are noted in patients with the overlap syndrome of COPD and obstructive sleep apnea versus COPD alone. There are potential benefits of noninvasive positive pressure ventilation therapy for overlap syndrome patients with hypercapnia. Nocturnal supplemental oxygen may be beneficial in certain COPD subtypes. Nonbenzodiazepine hypnotic therapy for insomnia has shown benefit without associated respiratory failure or worsening respiratory symptoms. Melatonin may provide mild hypnotic and antioxidant benefits. This article discusses the impact of sleep disorders on COPD patients and the potential benefits of managing sleep disorders on respiratory disease control and quality of life.

  4. Factors related to respiration influencing survival and respiratory function in patients with amyotrophic lateral sclerosis: a retrospective study.

    PubMed

    Leonardis, L; Dolenc Grošelj, L; Vidmar, G

    2012-12-01

    Various breathing abnormalities (Neurology 2009; 73: 1218) have been proposed as indicators for the introduction of non-invasive positive-pressure ventilation (NIV) in patients with amyotrophic lateral sclerosis (ALS). We were interested in the usefulness of symptoms of respiratory insufficiency and abnormal results of daytime arterial gas analyses (AGA) as predictors of survival and the effect of NIV on respiratory volumes and pressures. Reported symptoms, respiratory subscore of the ALS Functional Rating Scale (ALSFRS-r), Norris scale (Norris-r), and AGA were retrospectively analyzed in 189 ALS patients. Longitudinal follow-up of forced vital capacity (FVC), maximal inspiratory and expiratory pressure (MIP, MEP), and sniff nasal pressure (SNP) were analyzed with regard to the introduction of NIV. Respiratory symptoms were a bad prognostic sign (P = 0.007). Abnormalities in Norris-r, ALSFRS-r, pO(2), pCO(2), and oxygen saturation tended to be associated with a shorter survival, although they were not statistically significant. NIV prolonged survival and reduced the decline in FVC (P = 0.007), MIP, MEP, and SNP (the last three were not statistically significant). Symptoms, abnormal FVC, and AGA do not always coincide, and they can appear in a different sequence. Any respiratory abnormality should prompt the clinician to start discussing NIV with the patient. NIV prolongs survival and improves respiratory function. © 2012 The Author(s) European Journal of Neurology © 2012 EFNS.

  5. Comparison of biochemical stress indicators in juvenile captive estuarine crocodiles (Crocodylus porosus) following physical restraint or chemical restraint by midazolam injection.

    PubMed

    Olsson, Annabelle; Phalen, David

    2013-07-01

    Using a prospective, randomized study design we demonstrate that midazolam sedation minimizes acidosis compared with physical restraint in captive juvenile estuarine crocodiles during handling or noninvasive procedures at preferred body temperature. A dose of midazolam (5.0 mg/kg) was administered intramuscularly into the forelimb of 20 male estuarine crocodiles weighing 2-3.5 kg. Their heart and respiratory rate and degree of sedation were monitored until recovery and then daily for 7 subsequent days. Blood samples were taken at 30, 60, 90, 180, and 360 min. We recorded lactate, partial pressure of carbon dioxide (CO2), hematocrit, glucose, and blood pH. A second group (1.9-2.6 kg) was physically restrained for 5 min and the same parameters recorded. Physically restrained animals demonstrated elevated heart rate, respiratory rate, glucose, lactate, and anion gap compared with the midazolam-treated group. Physically restrained animals had lower pH, bicarbonate, and partial pressure of CO2 compared with the midazolam-treated group. Behavior in the physically restrained group in the days following the study was disrupted, with reluctance to feed and bask, compared with midazolam-treated animals whose behavior was normal. We conclude that midazolam administered in the forelimb of captive estuarine crocodiles of 2-3.5 kg provides predictable onset and duration of sedation enabling physical examination, sample collection, and translocation of the animals with minimal disturbance to lactate, pH, and CO2. Behavior following recovery appears normal.

  6. Ethical considerations with the management of congenital central hypoventilation syndrome.

    PubMed

    Massie, John; Gillam, Lynn

    2015-05-01

    Congenital central hypoventilation syndrome (CCHS) is a well-recognized disorder of the autonomic nervous system caused by mutations in the PHOX2B gene. The most characteristic feature is failure of ventilatory control, resulting in the need for respiratory support while asleep, and in some cases when awake also. Most cases present in infancy or early childhood. Technological advances allow patients with mild to moderate phenotypesto receive adequate support by non-invasive ventilation (NIV), or diaphragm pacing (or combination of the two) avoiding the need for long-term ventilation by tracheostomy. Daytime functioning of patients with CCHS who require sleep-time ventilation only is expected to be good, with some additional surveillance to ensure they don't accidentally fall asleep without respiratory support available. Some children with CCHS have other complications, such as Hirschprung's disease, learning difficulties, and cardiac arrhythmias (leading in some instances to heart block and the requirement for a pacemaker). In a few cases, patients can develop neurogenic malignancies. Parents bear a significant burden for the care of their child with CCHS including provision of NIV at home, close monitoring, and regular surveillance for complications. Information about patients with CCHS comes from databases in the United States and Europe, but these don't include infants or children for whom ventilator support was not offered. In this paper we use a case study to explore the ethical issues of provision of treatment, or non-treatment, of children with CCHS. © 2014 Wiley Periodicals, Inc.

  7. Acoustic sensor versus electrocardiographically derived respiratory rate in unstable trauma patients.

    PubMed

    Yang, Shiming; Menne, Ashley; Hu, Peter; Stansbury, Lynn; Gao, Cheng; Dorsey, Nicolas; Chiu, William; Shackelford, Stacy; Mackenzie, Colin

    2017-08-01

    Respiratory rate (RR) is important in many patient care settings; however, direct observation of RR is cumbersome and often inaccurate, and electrocardiogram-derived RR (RR ECG ) is unreliable. We asked how data derived from the first 15 min of RR recording after trauma center admission using a novel acoustic sensor (RR a ) would compare to RR ECG and to end-tidal carbon dioxide-based RR ([Formula: see text]) from intubated patients, the "gold standard" in predicting life-saving interventions in unstable trauma patients. In a convenience sample subset of trauma patients admitted to our Level 1 trauma center, enrolled in the ONPOINT study, and monitored with RR ECG , some of whom also had [Formula: see text] data, we collected RRa using an adhesive sensor with an integrated acoustic transducer (Masimo RRa™). Using Bland-Altman analysis of area under the receiver operating characteristic (AUROC) curves, we compared the first 15 min of continuous RRa and RR ECG to [Formula: see text] and assessed the performance of these three parameters compared to the Revised Trauma Score (RTS) in predicting blood transfusion 3, 6, and 12 h after admission. Of the 1200 patients enrolled in ONPOINT from December 2011 to May 2013, 1191 had RR ECG data recorded in the first 15 min, 358 had acoustic monitoring, and 14 of the latter also had [Formula: see text]. The three groups did not differ demographically or in mechanism of injury. RR a showed less bias (0.8 vs. 6.9) and better agreement than RR ECG when compared to [Formula: see text]. At [Formula: see text] 10-29 breaths per minute, RR a was more likely to be the same as [Formula: see text] and assign the same RTS. In predicting transfusion, features derived from RR a and RR ECG gave AUROCs 0.59-0.66 but with true positive rate 0.70-0.89. RR a monitoring is a non-invasive option to glean valid RR data to assist clinical decision making and could contribute to prediction models in non-intubated unstable trauma patients.

  8. Can non-invasive measurement of gut oxygenation predict necrotizing enterocolitis in preterm infants?

    USDA-ARS?s Scientific Manuscript database

    Factors that contribute to the development of NEC include hypoperfusion or decreased oxygenation of splanchnic tissue. Near-Infrared Spectroscopy (NIRS) will be used to assess gut oxygenation non-invasively. Typically NIRS is primarily used for cerebral hemodynamic monitoring; we intend to apply it ...

  9. Continuous on-line measurements of respiratory system, lung and chest wall mechanics during mechanic ventilation.

    PubMed

    Kárason, S; Søndergaard, S; Lundin, S; Stenqvist, O

    2001-08-01

    We present a concept of on-line, manoeuvre-free monitoring of respiratory mechanics during dynamic conditions, displaying calculated alveolar pressure/volume curves continuously and separating lung and chest wall mechanics. Prospective observational study. Intensive care unit of a university hospital. Ten ventilator-treated patients with acute lung injury. Different positive end-expiratory pressure (PEEP) and tidal volumes, low flow inflation. Previously validated methods were used to present a single-value dynostatic compliance for the whole breath and a dynostatic volume-dependent initial, middle and final compliance within the breath. A high individual variation of respiratory mechanics was observed. Reproducibility of repeated measurements was satisfactory (coefficients of variations for dynostatic volume-dependent compliance: < or =9.2% for total respiratory system, < or =18% for lung). Volume-dependent compliance showed a statistically significant pattern of successively decreasing compliance from the initial segment through the middle and final parts within each breath at all respiratory settings. This pattern became more prominent with increasing PEEP and tidal volume, indicating a greater distension of alveoli. No lower inflection point (LIP) was seen in patients with respiratory rate 20/min and PEEP at 4 cmH2O. A trial with low flow inflation in four of the patients showed formation of a LIP in three of them and an upper inflection in one. The monitoring concept revealed a constant pattern of successively decreasing compliance within each breath, which became more prominent with increasing PEEP and tidal volume. The monitoring concept offers a simple and reliable method of monitoring respiratory mechanics during ongoing ventilator treatment.

  10. Low-cost and disposable pressure sensor mat for non-invasive sleep and movement monitoring applications.

    PubMed

    Abraham, Jose K; Sullivan, Shawn; Ranganathan, Sridhar

    2011-01-01

    Sleep has profound effects on the physical and mental well-being of an individual. The National Institutes of Health (NIH) Sleep Disorder Research Plan gives particular emphasis to non-invasive sleep monitoring methods. Older adults experience sleep fragmentation due to sleep disorders. Unobtrusive non-contact monitoring can be the only realistic solution for long term home-based sleep monitoring. The demand for a low-cost and non-invasive sleep monitoring system for in-home use is more than before due to an increasingly stressful life style. Cost and complexity of current sensor elements hinder the development of low-cost sleep monitoring devices for in-home use. This paper presents the design, development and implementation of a low-cost and disposable pressure sensor mat that could be useful for in-home sleep and movement monitoring applications. The sensor mat design is based on a compressible foam sandwiched between two orthogonal arrays of cPaper capacitance sensors. A low-cost conducting paper has been developed for use as the capacitance sensor electrode. Typical mat design uses a 3 mm thick foam with 5 mm row/column grid array shows that it has a measurement resolution of 0.1 PSI pressure. The resolution can be controlled by both modifying properties of the conducting paper and the foam. Since this pressure mat design is based on low-cost paper, the sensor electrodes are disposable or semi-durable and hence it is ideal for the use in point-of-care physiological monitoring, pervasive healthcare and consumer electronic devices.

  11. Ventilatory support in critically ill hematology patients with respiratory failure

    PubMed Central

    2012-01-01

    Introduction Hematology patients admitted to the ICU frequently experience respiratory failure and require mechanical ventilation. Noninvasive mechanical ventilation (NIMV) may decrease the risk of intubation, but NIMV failure poses its own risks. Methods To establish the impact of ventilatory management and NIMV failure on outcome, data from a prospective, multicenter, observational study were analyzed. All hematology patients admitted to one of the 34 participating ICUs in a 17-month period were followed up. Data on demographics, diagnosis, severity, organ failure, and supportive therapies were recorded. A logistic regression analysis was done to evaluate the risk factors associated with death and NIVM failure. Results Of 450 patients, 300 required ventilatory support. A diagnosis of congestive heart failure and the initial use of NIMV significantly improved survival, whereas APACHE II score, allogeneic transplantation, and NIMV failure increased the risk of death. The risk factors associated with NIMV success were age, congestive heart failure, and bacteremia. Patients with NIMV failure experienced a more severe respiratory impairment than did those electively intubated. Conclusions NIMV improves the outcome of hematology patients with respiratory insufficiency, but NIMV failure may have the opposite effect. A careful selection of patients with rapidly reversible causes of respiratory failure may increase NIMV success. PMID:22827955

  12. Radio-frequency tracking of respiratory equipment: rationale and early experience at the Cleveland Clinic.

    PubMed

    Stoller, James K; Roberts, Vincent; Matt, David; Chom, Leslie; Sasidhar, Madhu; Chatburn, Robert L

    2013-12-01

    When respiratory therapists (RTs) seek respiratory care equipment, finding it quickly is desirable, both to expedite patient care and to avert RTs wasting time. To optimize RTs' ability to quickly locate ventilators, we developed and implemented a radio-frequency identification (RFID) tagging system called eTrak. The Clinical Engineering and Information Technology groups at Cleveland Clinic collaboratively developed a Wi-Fi-based RFID program that used active RFID tags. Altogether, 218 ventilators, 82 noninvasive ventilators, and various non-respiratory equipment were tagged, beginning in March 2010. We calculated the difference in time required to locate equipment before versus after implementation. The eTrak system had a mean 145 log-ons per week over the first year of use, and was associated with a decreased time required for RTs to locate ventilators: median 18 min (range 1-45 min) versus 3 min (range 1-6 min) (P < .001). Surveys of RTs regarding whether equipment was hard to find before versus after implementing eTrak showed a non-significant trend toward improvement. An RFID tracking system for respiratory equipment shortened the time to locate ventilators and non-significantly improved RT satisfaction with finding equipment. RFID tagging of equipment warrants further investigation.

  13. Occlusal overload investigations by noninvasive technology: fluorescence microscopy and en-face optical coherence tomography

    NASA Astrophysics Data System (ADS)

    Marcauteanu, Corina; Negrutiu, Meda; Sinescu, Cosmin; Demjan, Enikö; Hughes, Michael; Bradu, Adrian; Dobre, George; Podoleanu, Adrian G.

    2009-07-01

    The aim of this study is the early detection and monitoring of occlusal overload in bruxing patients. En-Face Optical coherence tomography (eF-OCT) and fluorescence microscopy (FM) were used for the imaging of several anterior teeth extracted from patients with light active bruxism. We found a characteristic pattern of enamel cracks, that reached the tooth surface. We concluded that the combination of the en-Face OCT and FM is a promising non-invasive alternative technique for reliable monitoring of occlusal overload.

  14. The Role of Incentive Spirometry in Primary Spontaneous Pneumothorax.

    PubMed

    Pribadi, Rabbinu R; Singh, Gurmeet; Rumende, Cleopas M

    2016-01-01

    Pneumothorax is the presence of air in the pleural space. Its management consists of noninvasive and invasive therapies and it is determined based on clinical manifestations, type and size of pneumothorax. We present a case of a patient with diagnosis of primary spontaneous pneumothorax treated with incentive spirometry (noninvasive therapy). A 20 year old man came to respirology clinic with chief complaint of shortness of breath. He was recently diagnosed with left pneumothorax based on previous chest X-ray in another health care facilities and was advised to undergo tube thoracostomy but he refused the procedure. On physical examination, vital signs were normal. Chest X-ray showed 33% of pneumothorax or 1.2 cm. He was asked to perform incentive spirometry therapy at home. During 12 days of therapy, shortness of breath slowly disappeared and on repeated chest X-ray, it showed minimal pneumothorax in the left upper hemithorax. Noninvasive treatment such as incentive spirometry can be considered in patient with minimal symptoms and no signs of life-threatening respiratory distress.

  15. Late Intensive Care Unit Admission in Liver Transplant Recipients: 10-Year Experience.

    PubMed

    Atar, Funda; Gedik, Ender; Kaplan, Şerife; Zeyneloğlu, Pınar; Pirat, Arash; Haberal, Mehmet

    2015-11-01

    We evaluated late intensive care unit admission in liver transplant recipients to identify incidences and causes of acute respiratory failure in the postoperative period and to compare these results with results in patients who did not have acute respiratory failure. We retrospectively screened the data of 173 consecutive adult liver transplant recipients from January 2005 through March 2015 to identify patients with late admission (> 30 d posttransplant) to an intensive care unit. Patients were divided into 2 groups: patients with and without acute respiratory failure. Acute respiratory failure was defined as severe dyspnea, respiratory distress, decreased oxygen saturation, hypoxemia or hypercapnia on room air, or need for noninvasive or invasive mechanical ventilation. Demographic, laboratory, clinical, and respiratory data were collected. Model for End-Stage Liver Disease, Acute Physiology and Chronic Health Evaluation II, and Sequential Organ Failure Assessment scores; lengths of intensive care unit and hospital stays; and hospital mortality were assessed. Among 173 patients, 37 (21.4%) were admitted to an intensive care unit, including 22 (59.5%) with acute respiratory failure. The leading cause of acute respiratory failure was pneumonia (n = 19, 86.4%). Patients with acute respiratory failure had significantly lower levels of albumin before intensive care unit admission (P = .003). In patients with acute respiratory failure, severe sepsis and septic shock were more frequently observed and tracheotomy was more frequently performed (P = .041). Acute respiratory failure developed in 59.5% of liver transplant recipients with late intensive care unit admission. The leading cause was pneumonia, with this group of patients having higher requirements for invasive mechanical ventilation and tracheotomy, longer stays in an intensive care unit, and higher mortality.

  16. [Types of ventilatory support and their indications in amyotrophic lateral sclerosis].

    PubMed

    Perrin, C

    2006-06-01

    Respiratory muscle weakness represents the major cause of mortality in patients with amyotrophic lateral sclerosis (ALS). As a result, ventilatory assistance is an important part of disease management. Nowadays, noninvasive ventilation (NIV) has become the first choice modality for most patients and represents an alternative to tracheostomy intermittent positive-pressure ventilation. Although, some consensus guidelines have been proposed to initiate NIV in patients with restrictive chronic respiratory failure, these criteria are discussed regarding ALS. While the current consensus recommends that NIV may be used in symptomatic patients with hypercapnia or forced vital capacity<50p.cent of predicted value, early use of NIV is proposed in the literature and reported in this paper.

  17. Management of respiratory problems in people with neurodegenerative conditions: a narrative review.

    PubMed

    Jones, U; Enright, S; Busse, M

    2012-03-01

    Respiratory failure and dysfunction are common problems in many neurodegenerative conditions. Although physiotherapists manage these problems, it is not known which treatments have been studied and their efficacy. To review evidence on the management of respiratory problems in people with neurodegenerative conditions using the PRISMA approach. Comprehensive searches were conducted using the following electronic databases from inception to May 2010: HUGEnet, SIGLE, British Library Direct, CINAHL, Medline, AMED and Web of Knowledge. Bibliographies of all studies and systematic reviews were searched by hand. Studies were selected based on: self-ventilating participants with neurodegenerative conditions; interventions aimed at improving respiratory function; and any valid and reliable measures of respiratory function as outcomes. Studies were appraised by one reviewer using the Critical Appraisal Skills Programme. Data were synthesised using a narrative approach. Thirty-five studies were included in the review. The strongest evidence was for the use of non-invasive ventilation for people with amyotrophic lateral sclerosis, although this was weak. The evidence for the use of respiratory muscle training and methods to increase peak cough flow showed a positive effect, but was also weak. There is weak evidence for the positive effects of physiotherapeutic interventions for respiratory problems in people with neurodegenerative conditions. Further work is necessary in specific neurodegenerative conditions to identify why respiratory problems occur, and larger scale studies should be undertaken to investigate management of these problems. Copyright © 2011 Chartered Society of Physiotherapy. Published by Elsevier Ltd. All rights reserved.

  18. Occupational and Environmental Bronchiolar Disorders

    PubMed Central

    Cummings, Kristin J.; Kreiss, Kathleen

    2015-01-01

    Occupational and environmental causes of bronchiolar disorders are recognized on the basis of case reports, case series, and, less commonly, epidemiologic investigations. Pathology may be limited to the bronchioles or also involve other components of the respiratory tract, including the alveoli. A range of clinical, functional, and radiographic findings, including symptomatic disease lacking abnormalities on noninvasive testing, poses a diagnostic challenge and highlights the value of surgical biopsy. Disease clusters in workplaces and communities have identified new etiologies, drawn attention to indolent disease that may otherwise have been categorized as idiopathic, and expanded the spectrum of histopathologic responses to an exposure. More sensitive noninvasive diagnostic tools, evidence-based therapies, and ongoing epidemiologic investigation of at-risk populations are needed to identify, treat, and prevent exposure-related bronchiolar disorders. PMID:26024345

  19. A Wearable Capacitive Sensor for Monitoring Human Respiratory Rate

    NASA Astrophysics Data System (ADS)

    Kundu, Subrata Kumar; Kumagai, Shinya; Sasaki, Minoru

    2013-04-01

    Realizing an untethered, low-cost, and comfortably wearable respiratory rate sensor for long-term breathing monitoring application still remains a challenge. In this paper, a conductive-textile-based wearable respiratory rate sensing technique based on the capacitive sensing approach is proposed. The sensing unit consists of two conductive textile electrodes that can be easily fabricated, laminated, and integrated in garments. Respiration cycle is detected by measuring the capacitance of two electrodes placed on the inner anterior and posterior sides of a T-shirt at either the abdomen or chest position. A convenient wearable respiratory sensor setup with a capacitance-to-voltage converter has been devised. Respiratory rate as well as breathing mode can be accurately identified using the designed sensor. The sensor output provides significant information on respiratory flow. The effectiveness of the proposed system for different breathing patterns has been evaluated by experiments.

  20. 21 CFR 868.2500 - Cutaneous oxygen (PcO2) monitor.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Cutaneous oxygen (PcO2) monitor. 868.2500 Section... (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Monitoring Devices § 868.2500 Cutaneous oxygen (PcO2) monitor. (a) Identification. A cutaneous oxygen (PcO2) monitor is a noninvasive, heated sensor (e.g., a...

  1. 21 CFR 868.2500 - Cutaneous oxygen (PcO 2) monitor.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Cutaneous oxygen (PcO 2) monitor. 868.2500 Section... (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Monitoring Devices § 868.2500 Cutaneous oxygen (PcO 2) monitor. (a) Identification. A cutaneous oxygen (PcO2) monitor is a noninvasive, heated sensor (e.g., a...

  2. 21 CFR 868.2500 - Cutaneous oxygen (PcO 2) monitor.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Cutaneous oxygen (PcO 2) monitor. 868.2500 Section... (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Monitoring Devices § 868.2500 Cutaneous oxygen (PcO 2) monitor. (a) Identification. A cutaneous oxygen (PcO2) monitor is a noninvasive, heated sensor (e.g., a...

  3. 21 CFR 868.2500 - Cutaneous oxygen (PcO2) monitor.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Cutaneous oxygen (PcO2) monitor. 868.2500 Section... (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Monitoring Devices § 868.2500 Cutaneous oxygen (PcO2) monitor. (a) Identification. A cutaneous oxygen (PcO2) monitor is a noninvasive, heated sensor (e.g., a...

  4. 21 CFR 868.2500 - Cutaneous oxygen (PcO2) monitor.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Cutaneous oxygen (PcO2) monitor. 868.2500 Section... (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Monitoring Devices § 868.2500 Cutaneous oxygen (PcO2) monitor. (a) Identification. A cutaneous oxygen (PcO2) monitor is a noninvasive, heated sensor (e.g., a...

  5. Sensor system for non-invasive optical carboxy-and methemoglobin determination

    NASA Astrophysics Data System (ADS)

    Timm, Ulrich; Gewiss, Helge; Kraitl, Jens; Brock, Beate; Ewald, Hartmut

    2017-02-01

    The pulse oximetry is a non-invasive method to monitor the oxygen saturation and is clinically used for many years. However this technology has some limitations. In case of the presence of dysfunctional hemoglobin derivatives as carboxyhemoglobin (COHb) or methemoglobin (MetHb) the readings of the pulse oximeter are distorted. This erroneous diagnosis of the patient's status can result in a life threatening situation. This paper will describe a sensor system for noninvasive determination of carboxy- and methemoglobin.

  6. Functional Magnetic Stimulation of Inspiratory and Expiratory Muscles in Subjects With Tetraplegia.

    PubMed

    Zhang, Xiaoming; Plow, Ela; Ranganthan, Vinoth; Huang, Honglian; Schmitt, Melissa; Nemunaitis, Gregory; Kelly, Clay; Frost, Frederick; Lin, Vernon

    2016-07-01

    Respiratory complications are major causes of morbidity and mortality in persons with a spinal cord injury, partly because of respiratory muscle paralysis. Earlier investigation has demonstrated that functional magnetic stimulation (FMS) can be used as a noninvasive technology for activating expiratory muscles, thus producing useful expiratory functions (simulated cough) in subjects with spinal cord injury. To evaluate the effectiveness of FMS for conditioning inspiratory and expiratory muscles in persons with tetraplegia. A prospective before and after trial. FMS Laboratory, Louis Stokes Cleveland VA Medical Center, Cleveland, OH. Six persons with tetraplegia. Each subject participated in a 6-week FMS protocol for conditioning the inspiratory and expiratory muscles. A magnetic stimulator was used with the center of a magnetic coil placed at the C7-T1 and T9-T10 spinous processes, respectively. Pulmonary function tests were performed before, during, and after the protocol. Respiratory variables included maximal inspiratory pressure (MIP), inspiratory reserve volume (IRV), peak inspiratory flow (PIF), maximal expiratory pressure (MEP), expiratory reserve volume (ERV), and peak expiratory flow (PEF). After 6 weeks of conditioning, the main outcome measurements (mean ± standard error) were as follows: MIP, 89.6 ± 7.3 cm H2O; IRV, 1.90 ± 0.34 L; PIF, 302.4 ± 36.3 L/min; MEP, 67.4 ± 11.1 cm H2O; ERV, 0.40 ± 0.06 L; and PEF, 372.4 ± 31.9 L/min. These values corresponded to 117%, 107%, 136%, 109%, 130%, and 124% of pre-FMS conditioning values, respectively. Significant improvements were observed in MIP (P = .022), PIF (P = .0001), and PEF (P = .0006), respectively. When FMS was discontinued for 4 weeks, these values showed decreases from their values at the end of the conditioning protocol, which suggests that continual FMS may be necessary to maintain improved respiratory functions. FMS conditioning of the inspiratory and expiratory muscles improved voluntary inspiratory and expiratory functions. FMS may be a noninvasive technology for respiratory muscle training in persons with tetraplegia. Copyright © 2016 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.

  7. Influence of different interfaces on synchrony during pressure support ventilation in a pediatric setting: a bench study.

    PubMed

    Conti, Giorgio; Gregoretti, Cesare; Spinazzola, Giorgia; Festa, Olimpia; Ferrone, Giuliano; Cipriani, Flora; Rossi, Marco; Piastra, Marco; Costa, Roberta

    2015-04-01

    In adults and children, patient-ventilator synchrony is strongly dependent on both the ventilator settings and interface used in applying positive pressure to the airway. The aim of this bench study was to determine whether different interfaces and ventilator settings may influence patient-ventilator interaction in pediatric models of normal and mixed obstructive and restrictive respiratory conditions. A test lung, connected to a pediatric mannequin using different interfaces (endotracheal tube [ETT], face mask, and helmet), was ventilated in pressure support ventilation mode testing 2 ventilator settings (pressurization time [Timepress]50%/cycling-off flow threshold [Trexp]25%, Timepress80%/Trexp60%), randomly applied. The test lung was set to simulate one pediatric patient with a healthy respiratory system and another with a mixed obstructive and restricted respiratory condition, at different breathing frequencies (f) (30, 40, and 50 breaths/min). We measured inspiratory trigger delay, pressurization time, expiratory trigger delay, and time of synchrony. At each breathing frequency, the helmet showed the longest inspiratory trigger delay compared with the ETT and face mask. At f30, the ETT had a reduced Tpress. The helmet had the shortest Tpress in the simulated child with a mixed obstructive and restricted respiratory condition, at f40 during Timepress50%/Trexp25% and at f50 during Timepress80%/Trexp60%. In the simulated child with a normal respiratory condition, the ETT presented the shortest Tpress value at f50 during Timepress80%/Trexp60%. Concerning the expiratory trigger delay, the helmet showed the best interaction at f30, but the worst at f40 and at f50. The helmet showed the shortest time of synchrony during all ventilator settings. The choice of the interface can influence patient-ventilator synchrony in a pediatric model breathing at increased f, thus making it more difficult to set the ventilator, particularly during noninvasive ventilation. The helmet demonstrated the worst interaction, suggesting that the face mask should be considered as the first choice for delivering noninvasive ventilation in a pediatric model. Copyright © 2015 by Daedalus Enterprises.

  8. Monte Carlo simulation of non-invasive glucose measurement based on FMCW LIDAR

    NASA Astrophysics Data System (ADS)

    Xiong, Bing; Wei, Wenxiong; Liu, Nan; He, Jian-Jun

    2010-11-01

    Continuous non-invasive glucose monitoring is a powerful tool for the treatment and management of diabetes. A glucose measurement method, with the potential advantage of miniaturizability with no moving parts, based on the frequency modulated continuous wave (FMCW) LIDAR technology is proposed and investigated. The system mainly consists of an integrated near-infrared tunable semiconductor laser and a detector, using heterodyne technology to convert the signal from time-domain to frequency-domain. To investigate the feasibility of the method, Monte Carlo simulations have been performed on tissue phantoms with optical parameters similar to those of human interstitial fluid. The simulation showed that the sensitivity of the FMCW LIDAR system to glucose concentration can reach 0.2mM. Our analysis suggests that the FMCW LIDAR technique has good potential for noninvasive blood glucose monitoring.

  9. Application of optical coherence tomography for noninvasive blood glucose monitoring during hyperglycemia

    NASA Astrophysics Data System (ADS)

    Larin, Kirill V.; Ashitkov, Taras V.; Motamedi, Massoud; Esenaliev, Rinat O.

    2003-10-01

    Approximately 14 million people in the USA and more than 140 million people worldwide suffer from Diabetes Mellitus. The current glucose sensing technique involves a finger puncture several times a day to obtain a droplet of blood for chemical analysis. Recently we proposed to use optical coherence tomography (OCT) for continuous noninvasive blood glucose sensing through skin. In this paper we tested the OCT technique for noninvasive monitoring of blood glucose concentration in lip tissue of New Zealand rabbits and Yucatan micropigs during glucose clamping experiments. Obtained results show good agreement with results obtained in skin studies, good correlation of changes in the OCT signal slope measured at the depth of 250 to 500 μm with changes in blood glucose concentration, and higher stability of the OCT data points than that obtained from skin.

  10. Millimeter-Wave Sensing of Diabetes-Relevant Glucose Concentration Changes in Pigs

    NASA Astrophysics Data System (ADS)

    Cano-Garcia, Helena; Saha, Shimul; Sotiriou, Ioannis; Kosmas, Panagiotis; Gouzouasis, Ioannis; Kallos, Efthymios

    2018-06-01

    The paper presents the first in vivo glucose monitoring animal study in a pig, which correlates radio frequency signal transmission changes with changes in blood glucose concentration in the 58-62 GHz frequency range. The presented non-invasive glucose sensing system consists of two opposite facing patch antennas sandwiching glucose-loaded samples. Prior to the animal study, the system was tested using saline solution samples, for which a linear relationship between changes in transmitted signal and glucose concentration was observed. In the animal study, glucose concentration changes were induced by injecting a known glucose solution in the blood stream. The non-invasive transmission measurements were compared to the glucose levels obtained invasively from the animal. Our results suggest that the system can detect spikes in glucose concentration in the blood, which is an important milestone towards non-invasive glucose monitoring.

  11. Respiratory Belt Transducer Constructed Using a Singing Greeting Card Beeper

    ERIC Educational Resources Information Center

    Bhaskar, Anand; Subramani, Selvam; Ojha, Rajdeep

    2013-01-01

    An article by Belusic and Zupancic described the construction of a finger pulse sensor using a singing greeting card beeper. These authors felt that this beeper made of piezoelectric material could be easily modified to function as a respiratory belt transducer to monitor respiratory movements. Commercially available respiratory belt transducers,…

  12. Respiratory muscle function in infants with spinal muscular atrophy type I.

    PubMed

    Finkel, Richard S; Weiner, Daniel J; Mayer, Oscar H; McDonough, Joseph M; Panitch, Howard B

    2014-12-01

    To determine the feasibility and safety of respiratory muscle function testing in weak infants with a progressive neuromuscular disorder. Respiratory insufficiency is the major cause of morbidity and mortality in infants with spinal muscular atrophy type I (SMA-I). Tests of respiratory muscle strength, endurance, and breathing patterns can be performed safely in SMA-I infants. Useful data can be collected which parallels the clinical course of pulmonary function in SMA-I. An exploratory study of respiratory muscle function testing and breathing patterns in seven infants with SMA-I seen in our neuromuscular clinic. Measurements were made at initial study visit and, where possible, longitudinally over time. We measured maximal inspiratory (MIP) and transdiaphragmatic pressures, mean transdiaphragmatic pressure, airway occlusion pressure at 100 msec of inspiration, inspiratory and total respiratory cycle time, and aspects of relative thoracoabdominal motion using respiratory inductive plethysmography (RIP). The tension time index of the diaphragm and of the respiratory muscles, phase angle (Φ), phase relation during the total breath, and labored breathing index were calculated. Age at baseline study was 54-237 (median 131) days. Reliable data were obtained safely for MIP, phase angle, labored breathing index, and the invasive and non-invasive tension time indices, even in very weak infants. Data obtained corresponded to the clinical estimate of severity and predicted the need for respiratory support. The testing employed was both safe and feasible. Measurements of MIP and RIP are easily performed tests that are well tolerated and provide clinically useful information for infants with SMA-I. © 2014 Wiley Periodicals, Inc.

  13. "Cut-and-Paste" Manufacture of Multiparametric Epidermal Sensor Systems.

    PubMed

    Yang, Shixuan; Chen, Ying-Chen; Nicolini, Luke; Pasupathy, Praveenkumar; Sacks, Jacob; Su, Becky; Yang, Russell; Sanchez, Daniel; Chang, Yao-Feng; Wang, Pulin; Schnyer, David; Neikirk, Dean; Lu, Nanshu

    2015-11-04

    Multifunctional epidermal sensor systems (ESS) are manufactured with a highly cost and time effective, benchtop, and large-area "cut-and-paste" method. The ESS made out of thin and stretchable metal and conductive polymer ribbons can be noninvasively laminated onto the skin surface to sense electrophysiological signals, skin temperature, skin hydration, and respiratory rate. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. [Relation between ultrasound-measured diaphragm movement and partial pressure of carbon dioxide in blood from patients with acute hypercapnic respiratory failure after the start of noninvasive ventilation in an emergency department].

    PubMed

    Sánchez-Nicolás, José Andrés; Cinesi-Gómez, César; Villén-Villegas, Tomás; Piñera-Salmerón, Pascual; García-Pérez, Bartolo

    2016-10-01

    To evaluate the correlation between variations in ultrasound-measured diaphragm movement and changes in the arterial partial pressure of carbon dioxide (PCO2) after the start of noninvasive ventilation (NIV). RDescriptive study of a prospective case series comprised of nonconsecutive patients aged 18 years or older with hypercapnic respiratory failure who were placed on NIV in an emergency department. We recorded clinical data, blood gas measurements, and ultrasound measurements of diaphragm movement. Twenty-one patients with a mean (SD) age of 83 (13) years were studied; 11 (52.4%) were women. The mean (SD) range of diaphragm movement and PCO2 values at 4 moments were as follows: 1) at baseline: diaphragm movement, 13.90 (7.7) mm and PCO2, 71.75 (11.4) mm Hg; 2) after 15 minutes on NIV: diaphragm movement, 17.10 (9.1) mm; 3) at 1 hour: diaphragm movement, 22.40 (10.4) mm and PCO2, 63.45 (16.0) mm Hg; and 4) at 3 hours: diaphragm movement, 26.60 (19.5) mm and PCO2, 61.85 (13.0) mm Hg. We detected a statistically significant correlation between the difference in range of diaphragm movement at baseline and at 15 minutes and the decrease in PCO2 after 1 hour of NIV (r=-0.489, P=.035). In patients with hypercapnic respiratory failure, the increase in range of diaphragm movement 15 minutes after starting NIV is associated with a decrease in PCO2 after 1 hour.

  15. Enteral Nutrition Is a Risk Factor for Airway Complications in Subjects Undergoing Noninvasive Ventilation for Acute Respiratory Failure.

    PubMed

    Kogo, Mariko; Nagata, Kazuma; Morimoto, Takeshi; Ito, Jiro; Sato, Yuki; Teraoka, Shunsuke; Fujimoto, Daichi; Nakagawa, Atsushi; Otsuka, Kojiro; Tomii, Keisuke

    2017-04-01

    Early enteral nutrition is recommended for mechanically ventilated patients in several studies and guidelines. In contrast, the effects of early enteral nutrition on noninvasive ventilation (NIV) have not been investigated extensively. The lack of an established method of airway protection suggests that enteral nutrition administration to these patients could increase airway complications and worsen outcomes. Between January 2007 and January 2015, 150 patients were admitted to our respiratory department for acute respiratory failure and received NIV for >48 h. Of these, 107 subjects incapable of oral intake were retrospectively analyzed. Clinical background and complications were compared in subjects who did and did not receive enteral nutrition. Sixty of the 107 subjects (56%) incapable of oral intake who received NIV also received enteral nutrition. Serum albumin concentration was significantly lower in subjects who received enteral nutrition than in those who did not (mean 2.7 ± 0.68 mg/dL vs 3.0 ± 0.75 mg/dL, P = .048). The rate of airway complications was significantly higher (53% [32/60] vs 32% [15/47], P = .03), and median NIV duration was significantly longer (16 [interquartile range 7-43] d vs 8 [5-20] d, P = .02) in subjects who received enteral nutrition than in those who did not. Multivariate analysis showed that enteral nutrition was unrelated to in-hospital mortality. Among subjects receiving NIV, enteral nutrition was associated with increased risk of airway complications but did not affect mortality. Enteral nutrition should be carefully considered in these patients. Copyright © 2017 by Daedalus Enterprises.

  16. Acoustic method respiratory rate monitoring is useful in patients under intravenous anesthesia.

    PubMed

    Ouchi, Kentaro; Fujiwara, Shigeki; Sugiyama, Kazuna

    2017-02-01

    Respiratory depression can occur during intravenous general anesthesia without tracheal intubation. A new acoustic method for respiratory rate monitoring, RRa ® (Masimo Corp., Tokyo, Japan), has been reported to show good reliability in post-anesthesia care and emergency units. The purpose of this study was to investigate the reliability of the acoustic method for measurement of respiratory rate during intravenous general anesthesia, as compared with capnography. Patients with dental anxiety undergoing dental treatment under intravenous anesthesia without tracheal intubation were enrolled in this study. Respiratory rate was recorded every 30 s using the acoustic method and capnography, and detectability of respiratory rate was investigated for both methods. This study used a cohort study design. In 1953 recorded respiratory rate data points, the number of detected points by the acoustic method (1884, 96.5 %) was significantly higher than that by capnography (1682, 86.1 %) (P < 0.0001). In the intraoperative period, there was a significant difference in the LOA (95 % limits of agreement of correlation between difference and average of the two methods)/ULLOA (under the lower limit of agreement) in terms of use or non-use of a dental air turbine (P < 0.0001). In comparison between capnography, the acoustic method is useful for continuous monitoring of respiratory rate in spontaneously breathing subjects undergoing dental procedures under intravenous general anesthesia. However, the acoustic method might not accurately detect in cases in with dental air turbine.

  17. Environmental DNA from Residual Saliva for Efficient Noninvasive Genetic Monitoring of Brown Bears (Ursus arctos)

    PubMed Central

    Wheat, Rachel E.; Allen, Jennifer M.; Miller, Sophie D. L.; Wilmers, Christopher C.; Levi, Taal

    2016-01-01

    Noninvasive genetic sampling is an important tool in wildlife ecology and management, typically relying on hair snaring or scat sampling techniques, but hair snaring is labor and cost intensive, and scats yield relatively low quality DNA. New approaches utilizing environmental DNA (eDNA) may provide supplementary, cost-effective tools for noninvasive genetic sampling. We tested whether eDNA from residual saliva on partially-consumed Pacific salmon (Oncorhynchus spp.) carcasses might yield suitable DNA quality for noninvasive monitoring of brown bears (Ursus arctos). We compared the efficiency of monitoring brown bear populations using both fecal DNA and salivary eDNA collected from partially-consumed salmon carcasses in Southeast Alaska. We swabbed a range of tissue types from 156 partially-consumed salmon carcasses from a midseason run of lakeshore-spawning sockeye (O. nerka) and a late season run of stream-spawning chum (O. keta) salmon in 2014. We also swabbed a total of 272 scats from the same locations. Saliva swabs collected from the braincases of salmon had the best amplification rate, followed by swabs taken from individual bite holes. Saliva collected from salmon carcasses identified unique individuals more quickly and required much less labor to locate than scat samples. Salmon carcass swabbing is a promising method to aid in efficient and affordable monitoring of bear populations, and suggests that the swabbing of food remains or consumed baits from other animals may be an additional cost-effective and valuable tool in the study of the ecology and population biology of many elusive and/or wide-ranging species. PMID:27828988

  18. [Suspension of Respiratory Support in Patients with Amyotrophic Lateral Sclerosis].

    PubMed

    Silberberg, Agustín A; Robetto, Josefina; Achával, Mora

    2018-01-01

    Decision making in advanced Amyotrophic Lateral Sclerosis (ALS) patients keeps on being a controversial issue. The aim of this work is to discuss ethical implications of withdrawing respiratory support treatment in patients with ALS. Through a bibliographic search on Pubmed database (2010-2016) we investigated whether or not the use of Non-Invasive Ventilation (NIV) and Mechanical Ventilation (MV) would increase survival and quality of life. We included 38 review articles. From these papers, results and ethical implications of initiating and mainly withdrawing respiratory support were analyzed. Survival time increased with NIV and with MV. Quality of life, above all according to physiological criteria, improved with NIV but regarding MV it remained controversial. Implementation and future withdrawal of MV seemed open to medical and ethical discussion. From a perspective of the intrinsic dignity of every human being, whatever its quality of life was, and knowing that no effective therapies for the underlying disease are available, the decision to remove MV in a patient with advanced ALS requires: knowledge of the will of the patient and, above all, evaluating whether this respiratory support measure is becoming objectively disproportionate.

  19. Cystic fibrosis respiratory tract salt concentration: An Exploratory Cohort Study.

    PubMed

    Grandjean Lapierre, Simon; Phelippeau, Michael; Hakimi, Cyrine; Didier, Quentin; Reynaud-Gaubert, Martine; Dubus, Jean-Christophe; Drancourt, Michel

    2017-11-01

    In cystic fibrosis patients, electrolytic and osmolality imbalance secondary to cystic fibrosis transmembrane conductance regulator mutations may impact on mucoid secretion accumulation and secondary colonization by opportunistic pathogens such as nontuberculous mycobacteria.We performed a noninvasive exploratory prospective controlled clinical study comparing sputum salinity and acid-base characteristics of cystic fibrosis and noncystic fibrosis control patients. A total of 57 patients and 62 controls were included.Sputum salt concentrations were 10.5 g/L (95% CI: 7.7-13.3) in patients and 7.4 g/L (95% CI: 5.9-8.9) in aged-matched controls, a difference that was found to be statistically significant (P < .05). No difference in pH was observed between patients and controls.These differences in respiratory secretions salt concentrations could influence host-pathogen interactions in the context of cystic fibrosis respiratory infections. We propose to include respiratory secretion salt measurement as a routine analysis on cystic fibrosis patients' sputum submitted for bacterial culture. Copyright © 2017 The Authors. Published by Wolters Kluwer Health, Inc. All rights reserved.

  20. Effect of dynamic controlled atmosphere monitored by respiratory quotient and 1-methylcyclopropene on the metabolism and quality of 'Galaxy' apple harvested at three maturity stages.

    PubMed

    Thewes, Fabio Rodrigo; Brackmann, Auri; Anese, Rogerio de Oliveira; Ludwig, Vagner; Schultz, Erani Eliseu; Dos Santos, Luana Ferreira; Wendt, Lucas Mallmann

    2017-05-01

    The objective of this study was to evaluate the interaction between controlled atmosphere (CA), CA+1-methylcyclopropene (1-MCP) and dynamic controlled atmosphere monitored by respiratory quotient (DCA-RQ) with three fruit maturity stages at harvest (early harvest date, optimal harvest date and late harvest date) on 'Galaxy' apple metabolism and quality after harvest and 9months storage plus 7days of shelf life at 20°C. Fruit stored under dynamic controlled atmosphere monitored by respiratory quotient 1.3 (DCA-RQ 1.3) showed lower ethylene production, respiration rate, mealiness and higher flesh firmness in comparison to CA stored fruit, but did not differ from those treated with 1-MCP. The dynamic controlled atmosphere monitored by respiratory quotient 1.5 (DCA-RQ 1.5) increased the acetaldehyde, ethanol and ethyl acetate concentration, regardless of the fruit maturity at harvest. The storage of 'Galaxy' apple under DCA-RQ 1.3 is efficient in keeping quality regardless of the maturity stage at harvest. Copyright © 2016 Elsevier Ltd. All rights reserved.

  1. Non-invasive continuous blood pressure measurement based on mean impact value method, BP neural network, and genetic algorithm.

    PubMed

    Tan, Xia; Ji, Zhong; Zhang, Yadan

    2018-04-25

    Non-invasive continuous blood pressure monitoring can provide an important reference and guidance for doctors wishing to analyze the physiological and pathological status of patients and to prevent and diagnose cardiovascular diseases in the clinical setting. Therefore, it is very important to explore a more accurate method of non-invasive continuous blood pressure measurement. To address the shortcomings of existing blood pressure measurement models based on pulse wave transit time or pulse wave parameters, a new method of non-invasive continuous blood pressure measurement - the GA-MIV-BP neural network model - is presented. The mean impact value (MIV) method is used to select the factors that greatly influence blood pressure from the extracted pulse wave transit time and pulse wave parameters. These factors are used as inputs, and the actual blood pressure values as outputs, to train the BP neural network model. The individual parameters are then optimized using a genetic algorithm (GA) to establish the GA-MIV-BP neural network model. Bland-Altman consistency analysis indicated that the measured and predicted blood pressure values were consistent and interchangeable. Therefore, this algorithm is of great significance to promote the clinical application of a non-invasive continuous blood pressure monitoring method.

  2. Differential radioactivity monitor for non-invasive detection of ocular melanoma

    DOEpatents

    Lambrecht, R.M.; Packer, S.

    1982-09-23

    There is described an apparatus and method for diagnosing ocular cancer that is both non-invasive and accurate which comprises two radiation detectors positioned before each of the patient's eyes which will measure the radiation level produced in each eye after the administration of a tumor-localizing radiopharmaceutical such as gallium-67.

  3. Noninvasive, three-dimensional full-field body sensor for surface deformation monitoring of human body in vivo.

    PubMed

    Chen, Zhenning; Shao, Xinxing; He, Xiaoyuan; Wu, Jialin; Xu, Xiangyang; Zhang, Jinlin

    2017-09-01

    Noninvasive, three-dimensional (3-D), full-field surface deformation measurements of the human body are important for biomedical investigations. We proposed a 3-D noninvasive, full-field body sensor based on stereo digital image correlation (stereo-DIC) for surface deformation monitoring of the human body in vivo. First, by applying an improved water-transfer printing (WTP) technique to transfer optimized speckle patterns onto the skin, the body sensor was conveniently and harmlessly fabricated directly onto the human body. Then, stereo-DIC was used to achieve 3-D noncontact and noninvasive surface deformation measurements. The accuracy and efficiency of the proposed body sensor were verified and discussed by considering different complexions. Moreover, the fabrication of speckle patterns on human skin, which has always been considered a challenging problem, was shown to be feasible, effective, and harmless as a result of the improved WTP technique. An application of the proposed stereo-DIC-based body sensor was demonstrated by measuring the pulse wave velocity of human carotid artery. (2017) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE).

  4. Nasal high-flow oxygen therapy in patients with hypoxic respiratory failure: effect on functional and subjective respiratory parameters compared to conventional oxygen therapy and non-invasive ventilation (NIV).

    PubMed

    Schwabbauer, Norbert; Berg, Björn; Blumenstock, Gunnar; Haap, Michael; Hetzel, Jürgen; Riessen, Reimer

    2014-01-01

    Aim of the study was to compare the short-term effects of oxygen therapy via a high-flow nasal cannula (HFNC) on functional and subjective respiratory parameters in patients with acute hypoxic respiratory failure in comparison to non-invasive ventilation (NIV) and standard treatment via a Venturi mask. Fourteen patients with acute hypoxic respiratory failure were treated with HFNC (FiO2 0.6, gas flow 55 l/min), NIV (FiO2 0.6, PEEP 5 cm H2O Hg, tidal volume 6-8 ml/kg ideal body weight,) and Venturi mask (FiO2 0.6, oxygen flow 15 l/min,) in a randomized order for 30 min each. Data collection included objective respiratory and circulatory parameters as well as a subjective rating of dyspnea and discomfort by the patients on a 10-point scale. In a final interview, all three methods were comparatively evaluated by each patient using a scale from 1 (=very good) to 6 (=failed) and the patients were asked to choose one method for further treatment. PaO2 was highest under NIV (129 ± 38 mmHg) compared to HFNC (101 ± 34 mmHg, p <0.01 vs. NIV) and VM (85 ± 21 mmHg, p <0.001 vs. NIV, p <0.01 vs. HFNC, ANOVA). All other functional parameters showed no relevant differences. In contrast, dyspnea was significantly better using a HFNC (2.9 ± 2.1, 10-point Borg scale) compared to NIV (5.0 ± 3.3, p <0.05), whereas dyspnea rating under HFNC and VM (3.3 ± 2.3) was not significantly different. A similar pattern was found when patients rated their overall discomfort on the 10 point scale: HFNC 2.7 ± 1.8, VM 3.1 ± 2.8 (ns vs. HFNC), NIV 5.4 ± 3.1 (p <0.05 vs. HFNC). In the final evaluation patients gave the best ratings to HFNC 2.3 ± 1.4, followed by VM 3.2 ± 1.7 (ns vs. HFNC) and NIV 4.5 ± 1.7 (p <0.01 vs. HFNC and p <0.05 vs. VM). For further treatment 10 patients chose HFNC, three VM and one NIV. In hypoxic respiratory failure HFNC offers a good balance between oxygenation and comfort compared to NIV and Venturi mask and seems to be well tolerated by patients. GERMAN CLINICAL TRIALS REGISTER: DRKS00005132.

  5. A wearable physiological sensor suite for unobtrusive monitoring of physiological and cognitive state.

    PubMed

    Matthews, Robert; McDonald, Neil J; Hervieux, Paul; Turner, Peter J; Steindorf, Martin A

    2007-01-01

    This paper describes an integrated Physiological Sensor Suite (PSS) based upon QUASAR's innovative non-invasive bioelectric sensor technologies that will provide, for the first time, a fully integrated, noninvasive methodology for physiological sensing. The PSS currently under development at QUASAR is a state-of-the-art multimodal array of sensors that, along with an ultra-low power personal area wireless network, form a comprehensive body-worn system for real-time monitoring of subject physiology and cognitive status. Applications of the PSS extend from monitoring of military personnel to long-term monitoring of patients diagnosed with cardiac or neurological conditions. Results for side-by-side comparisons between QUASAR's biosensor technology and conventional wet electrodes are presented. The signal fidelity for bioelectric measurements using QUASAR's biosensors is comparable to that for wet electrodes.

  6. A novel approach to detect respiratory phases from pulmonary acoustic signals using normalised power spectral density and fuzzy inference system.

    PubMed

    Palaniappan, Rajkumar; Sundaraj, Kenneth; Sundaraj, Sebastian; Huliraj, N; Revadi, S S

    2016-07-01

    Monitoring respiration is important in several medical applications. One such application is respiratory rate monitoring in patients with sleep apnoea. The respiratory rate in patients with sleep apnoea disorder is irregular compared with the controls. Respiratory phase detection is required for a proper monitoring of respiration in patients with sleep apnoea. To develop a model to detect the respiratory phases present in the pulmonary acoustic signals and to evaluate the performance of the model in detecting the respiratory phases. Normalised averaged power spectral density for each frame and change in normalised averaged power spectral density between the adjacent frames were fuzzified and fuzzy rules were formulated. The fuzzy inference system (FIS) was developed with both Mamdani and Sugeno methods. To evaluate the performance of both Mamdani and Sugeno methods, correlation coefficient and root mean square error (RMSE) were calculated. In the correlation coefficient analysis in evaluating the fuzzy model using Mamdani and Sugeno method, the strength of the correlation was found to be r = 0.9892 and r = 0.9964, respectively. The RMSE for Mamdani and Sugeno methods are RMSE = 0.0853 and RMSE = 0.0817, respectively. The correlation coefficient and the RMSE of the proposed fuzzy models in detecting the respiratory phases reveals that Sugeno method performs better compared with the Mamdani method. © 2014 John Wiley & Sons Ltd.

  7. Amnesia for electric dental pulp stimulation and picture recall test under different levels of propofol or midazolam sedation.

    PubMed

    Matsuki, Y; Ichinohe, T; Kaneko, Y

    2007-01-01

    To compare the amnesic effect of propofol and midazolam to electric dental pulp stimulation (invasive) and picture recall test (non-invasive) at two sedation levels with the aid of bispectral index (BIS) monitoring. The subjects were 10 male volunteers (24-34 years) classified as ASA physical status I. Propofol was administered to achieve a sedation score of three with a target-controlled infusion technique; it was then regulated to give a sedation score of two (P group). Midazolam was administered by a titration dosage to achieve a sedation score of three (M group). It then gradually decreased to give a sedation score of two. The BIS score, sedation score, plasma/serum concentration of propofol and midazolam, blood pressure, pulse rate, respiratory rate, end-tidal CO(2) tension and arterial oxygen saturation were observed at each sedation level in both groups. Amnesic effects were evaluated using a picture recall test and electric dental pulp stimulation. No difference was observed in the amnesic effect evaluated by picture recall test at the two sedation levels. Likewise, there was no difference at a sedation score of three when the amnesic effect was evaluated by electric dental pulp stimulation. In contrast, a significant difference was observed at a sedation score of two; midazolam produced amnesia in more subjects than did propofol. Propofol and midazolam did not show any significant difference in amnesic effects to non-invasive stimuli. For invasive stimuli, midazolam showed a stronger amnesic effect at the moderate sedation level, but not at the deeper sedation level.

  8. SU-D-207A-06: Pediatric Abdominal Organ Motion Quantified Via a Novel 4D MRI Method

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Uh, J; Krasin, MJ; Lucas, JT

    Purpose: To develop a 4D MRI method for assessing respiration-induced abdominal organ motion in children receiving radiation therapy. Methods: A 4D MRI using internal image-based respiratory surrogate has been developed and implemented on a clinical scanner (1.5T Siemens Avanto). Ten patients (younger group: N=6, 2–5 years, anesthetized; older group: N=4, 11–15 years) with neuroblastoma, Wilm’s tumor rhabdomyosarcoma, or desmoplastic small round cell tumor received free breathing 4D MRI scans for treatment planning. Coronal image slices of the entire abdomen were retrospectively constructed in 10 respiratory phases. A B-spline deformable registration (Metz et al. 2011) was performed on 4D datasets tomore » automatically derive motion trajectories of selected anatomical landmarks, including the dome and the center of the liver, and the superior edges of kidneys and spleen. The extents of the motion in three dimensions (anteroposterior, AP; mediolateral, ML; superoinferior, SI) and the correlations between organ motion trajectories were quantified. Results: The 4D MRI scans were successfully performed in <20 minutes for all patients without the use of any external device. Organ motion extents were larger in adolescents (kidneys: 3–13 mm SI, liver and spleen: 6–18 mm SI) than in younger children (kidneys:<3mm in all directions; liver and spleen: 1–8 mm SI, 1–5 mm ML and AP). The magnitude of respiratory motion in some adolescents may warrant special motion management. Motion trajectories were not synchronized across selected anatomical landmarks, particularly in the ML and AP directions, indicating inter- and intra-organ variations of the respiratory-induced motion. Conclusion: The developed 4D MRI acquisition and motion analysis methods provide a non-ionizing, non-invasive approach to automatically measure the organ motion trajectory in the pediatric abdomen. It is useful for defining ITV and PRV, monitoring changes in target motion patterns during the treatment course, and studying interplay effects in proton scanning.« less

  9. Novel optoacoustic system for noninvasive continuous monitoring of cerebral venous blood oxygenation

    NASA Astrophysics Data System (ADS)

    Petrov, Yuriy; Petrov, Irene Y.; Prough, Donald S.; Esenaliev, Rinat O.

    2012-02-01

    Traumatic brain injury (TBI) and spinal cord injury are a major cause of death for individuals under 50 years of age. In the USA alone, 150,000 patients per year suffer moderate or severe TBI. Moreover, TBI is a major cause of combatrelated death. Monitoring of cerebral venous blood oxygenation is critically important for management of TBI patients because cerebral venous blood oxygenation below 50% results in death or severe neurologic complications. At present, there is no technique for noninvasive, accurate monitoring of this clinically important variable. We proposed to use optoacoustic technique for noninvasive monitoring of cerebral venous blood oxygenation by probing cerebral veins such as the superior sagittal sinus (SSS) and validated it in animal studies. In this work, we developed a novel, medical grade optoacoustic system for continuous, real-time cerebral venous blood oxygenation monitoring and tested it in human subjects at normal conditions and during hyperventilation to simulate changes that may occur in patients with TBI. We designed and built a highly-sensitive optoacoustic probe for SSS signal detection. Continuous measurements were performed in the near infrared spectral range and the SSS oxygenation absolute values were automatically calculated in real time using a special algorithm developed by our group. Continuous measurements performed at normal conditions and during hyperventilation demonstrated that hyperventilation resulted in approximately 12% decrease of cerebral venous blood oxygenation.

  10. Anaphylaxis Imaging: Non-Invasive Measurement of Surface Body Temperature and Physical Activity in Small Animals

    PubMed Central

    Manzano-Szalai, Krisztina; Pali-Schöll, Isabella; Krishnamurthy, Durga; Stremnitzer, Caroline; Flaschberger, Ingo; Jensen-Jarolim, Erika

    2016-01-01

    In highly sensitized patients, the encounter with a specific allergen from food, insect stings or medications may rapidly induce systemic anaphylaxis with potentially lethal symptoms. Countless animal models of anaphylaxis, most often in BALB/c mice, were established to understand the pathophysiology and to prove the safety of different treatments. The most common symptoms during anaphylactic shock are drop of body temperature and reduced physical activity. To refine, improve and objectify the currently applied manual monitoring methods, we developed an imaging method for the automated, non-invasive measurement of the whole-body surface temperature and, at the same time, of the horizontal and vertical movement activity of small animals. We tested the anaphylaxis imaging in three in vivo allergy mouse models for i) milk allergy, ii) peanut allergy and iii) egg allergy. These proof-of-principle experiments suggest that the imaging technology represents a reliable non-invasive method for the objective monitoring of small animals during anaphylaxis over time. We propose that the method will be useful for monitoring diseases associated with both, changes in body temperature and in physical behaviour. PMID:26963393

  11. Optoacoustic mapping of cerebral blood oxygenation in humans

    NASA Astrophysics Data System (ADS)

    Petrov, Yuriy; Prough, Donald S.; Petrov, Irene Y.; Richardson, C. Joan; Fonseca, Rafael A.; Robertson, Claudia S.; Esenaliev, Rinat O.

    2017-03-01

    Noninvasive, transcranial mapping, monitoring, and imaging are highly important for detection and management of cerebral abnormalities and neuroscience research. Mapping, imaging, and monitoring of cerebral blood oxygenation are necessary for diagnostics and management of patients with traumatic brain injury, stroke, and other neurological conditions. We proposed to use optoacoustic technology for noninvasive, transcranial monitoring and imaging. In this work, we developed optoacoustic systems for mapping of cerebral blood oxygenation in humans and tested them in adults and neonates. The systems provide noninvasive, transcranial optoacoustic measurements in the transmission (forward) and reflection (backward) modes in the near infrared spectral range. Novel, ultra-sensitive probes were built for detection of optoacoustic signals and measurement of blood oxygenation in neonates and adults. Cerebral oxygenation was measured at different lateral sites from the superior sagittal sinus (SSS), a large central cerebral vein, located immediately beneath the midline of the human skull. In neonates, cerebral oxygenation was measured through open anterior and posterior fontanelles. Optoacoustic signal detection at different locations allowed for mapping of cerebral blood oxygenation. Our future studies will be focused on 3D mapping of cerebral blood oxygenation.

  12. High-resolution ultrasound imaging and noninvasive optoacoustic monitoring of blood variables in peripheral blood vessels

    NASA Astrophysics Data System (ADS)

    Petrov, Irene Y.; Petrov, Yuriy; Prough, Donald S.; Esenaliev, Rinat O.

    2011-03-01

    Ultrasound imaging is being widely used in clinics to obtain diagnostic information non-invasively and in real time. A high-resolution ultrasound imaging platform, Vevo (VisualSonics, Inc.) provides in vivo, real-time images with exceptional resolution (up to 30 microns) using high-frequency transducers (up to 80 MHz). Recently, we built optoacoustic systems for probing radial artery and peripheral veins that can be used for noninvasive monitoring of total hemoglobin concentration, oxyhemoglobin saturation, and concentration of important endogenous and exogenous chromophores (such as ICG). In this work we used the high-resolution ultrasound imaging system Vevo 770 for visualization of the radial artery and peripheral veins and acquired corresponding optoacoustic signals from them using the optoacoustic systems. Analysis of the optoacoustic data with a specially developed algorithm allowed for measurement of blood oxygenation in the blood vessels as well as for continuous, real-time monitoring of arterial and venous blood oxygenation. Our results indicate that: 1) the optoacoustic technique (unlike pure optical approaches and other noninvasive techniques) is capable of accurate peripheral venous oxygenation measurement; and 2) peripheral venous oxygenation is dependent on skin temperature and local hemodynamics. Moreover, we performed for the first time (to the best of our knowledge) a comparative study of optoacoustic arterial oximetry and a standard pulse oximeter in humans and demonstrated superior performance of the optoacoustic arterial oximeter, in particular at low blood flow.

  13. Calibration Experiments Conducted for Noninvasive Blood Glucose Sensing Through the Eye

    NASA Technical Reports Server (NTRS)

    Ansari, Rafat R.; Bockle, Stefan; Suh, Kwang I.; Rovati, Luigi L.

    2004-01-01

    There are more than 16 million diabetics in the United States and more than 100 million worldwide. Diabetes can lead to severe complications over time such as blindness, renal and cardiovascular diseases, and peripheral neuropathy in the limbs. Poor blood circulation in diabetics can lead to gangrene and the subsequent amputation of extremities. In addition, this pathology is the fourth leading cause of death in the United States. The most effective way to manage diabetes is frequent blood glucose monitoring performed by the patients themselves. However, because of pain, inconvenience, and the fear of developing infections from finger-prick blood tests or implants, many patients monitor their blood glucose levels less frequently than is recommended by their physicians. Therefore, a noninvasive, painless, and convenient method to monitor blood glucose would greatly benefit diabetics. Likewise, detecting, preventing, and treating the untoward effects of prolonged space travel (e.g., a human mission to Mars) in real-time requires the development of noninvasive diagnostic technologies that are compact and powerful. As a "window to the body," the eye offers the opportunity to use light in various forms to detect ocular and systemic abnormalities long before clinical symptoms appear and to help develop preventative and therapeutic countermeasures early. The noninvasive feature of these technologies permits frequent repetition of tests, enabling an evaluation of the response to therapy.

  14. The growing role of noninvasive ventilation in patients requiring prolonged mechanical ventilation.

    PubMed

    Hess, Dean R

    2012-06-01

    For many patients with chronic respiratory failure requiring ventilator support, noninvasive ventilation (NIV) is preferable to invasive support by tracheostomy. Currently available evidence does not support the use of nocturnal NIV in unselected patients with stable COPD. Several European studies have reported benefit for high intensity NIV, in which setting of inspiratory pressure and respiratory rate are selected to achieve normocapnia. There have also been studies reporting benefit for the use of NIV as an adjunct to exercise training. NIV may be useful as an adjunct to airway clearance techniques in patients with cystic fibrosis. Accumulating evidence supports the use of NIV in patients with obesity hypoventilation syndrome. There is considerable observational evidence supporting the use of NIV in patients with chronic respiratory failure related to neuromuscular disease, and one randomized controlled trial reported that the use of NIV was life-prolonging in patients with amyotrophic lateral sclerosis. A variety of interfaces can be used to provide NIV in patients with stable chronic respiratory failure. The mouthpiece is an interface that is unique in this patient population, and has been used with success in patients with neuromuscular disease. Bi-level pressure ventilators are commonly used for NIV, although there are now a new generation of intermediate ventilators that are portable, have a long battery life, and can be used for NIV and invasive applications. Pressure support ventilation, pressure controlled ventilation, and volume controlled ventilation have been used successfully for chronic applications of NIV. New modes have recently become available, but their benefits await evidence to support their widespread use. The success of NIV in a given patient population depends on selection of an appropriate patient, selection of an appropriate interface, selection of an appropriate ventilator and ventilator settings, the skills of the clinician, the motivation of the patient, and the support of the family. 2012 Daedalus Enterprises

  15. Does Bilevel Positive Airway Pressure Improve Outcome of Acute Respiratory Failure after Open-heart Surgery?

    PubMed Central

    Elgebaly, Ahmed Said

    2017-01-01

    Background: Respiratory failure is of concern in the postoperative period after cardiac surgeries. Invasive ventilation (intermittent positive pressure ventilation [IPPV]) carries the risks and complications of intubation and mechanical ventilation (MV). Aims: Noninvasive positive pressure ventilation (NIPPV) is an alternative method and as effective as IPPV in treating insufficiency of respiration with less complications and minimal effects on respiratory and hemodynamic parameters next to open-heart surgery. Design: This is a prospective, randomized and controlled study. Materials and Methods: Forty-four patients scheduled for cardiac surgery were divided into two equal groups: Group I (IPPV) and Group II (NIPPV). Heart rate (HR), mean arterial pressure (MAP), respiratory rate (RR), oxygen saturation (SpO2), arterial blood gas, weaning time, reintubation, tracheotomy rate, MV time, postoperative hospital stay, and ventilator-associated pneumonia during the period of hospital stay were recorded. Results: There was statistically significant difference in HR between groups with higher in Group I at 30 and 60 min and at 12 and 24 h. According to MAP, it started to increase significantly at hypoxemia, 15 min, 30 min, 4 h, 12 h, and at 24 h which was higher in Group I also. RR, PaO2, and PaCO2 showed significant higher in Group II at 15, 30, and 60 min and 4 h. According to pH, there was a significant difference between groups at 15, 30, and 60 min and at 4, 12, and 24 h postoperatively. SpO2 showed higher significant values in Group I at 15 and 30 min and at 12 h postoperatively. Duration of postoperative supportive ventilation was higher in Group I than that of Group II with statistically significant difference. Complications were statistically insignificant between Group I and Group II. Conclusion: Our study showed superiority of invasive over noninvasive mode of ventilator support. However, NIPPV (bilevel positive airway pressure) was proved to be a safe method. PMID:28994676

  16. Relieving dyspnoea by non-invasive ventilation decreases pain thresholds in amyotrophic lateral sclerosis.

    PubMed

    Dangers, Laurence; Laviolette, Louis; Georges, Marjolaine; Gonzalez-Bermejo, Jésus; Rivals, Isabelle; Similowski, Thomas; Morelot-Panzini, Capucine

    2017-03-01

    Dyspnoea is a threatening sensation of respiratory discomfort that presents many similarities with pain. Experimental dyspnoea in healthy subjects induces analgesia. This 'dyspnoea-pain counter-irritation' could, in reverse, imply that relieving dyspnoea in patients with chronic respiratory diseases would lower their pain thresholds. We first determined pressure pain thresholds in 25 healthy volunteers (22-31 years; 13 men; handheld algometer), during unloaded breathing (BASELINE) and during inspiratory threshold loading (ITL). Two levels of loading were used, adjusted to induce dyspnoea self-rated at 60% or 80% of a 10 cm visual analogue scale (ITL6 and ITL8). 18 patients with chronic respiratory failure due to amyotrophic lateral sclerosis (ALS) were then studied during unassisted breathing and after 30 and 60 min of non-invasive ventilation-NIV30 and NIV60-(same dyspnoea evaluation). In healthy volunteers, pressure pain thresholds increased significantly in the deltoid during ITL6 (p<0.05) and ITL8 (p<0.05) and in the trapezius during ITL8 (p<0.05), validating the use of pressure pain thresholds to study dyspnoea-pain counter-irritation. In patients with ALS, the pressure pain thresholds measured in the deltoid during unassisted breathing decreased by a median of 24.5%-33.0% of baseline during NIV30 and NIV60 (p<0.05). Relieving dyspnoea by NIV in patients with ALS having respiratory failure is associated with decreased pressure pain thresholds. Clinical implications have yet to be determined, but this observation suggests that patients with ALS could become more susceptible to pain after the institution of NIV, hence the need for reinforced attention towards potentially painful diagnostic and therapeutic interventions. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  17. Non-Invasive Ventilation (NIV) and Homeostatic Model Assessment (HOMA) Index in Stable Chronic Obstructive Pulmonary Disease (COPD) Patients with Chronic Hypercapnic Respiratory Failure: A Pilot Study.

    PubMed

    Dimoulis, Andreas; Pastaka, Chaido; Tsolaki, Vasiliki; Tsilioni, Irini; Pournaras, Spyridon; Liakos, Nikolaos; Georgoulias, Panagiotis; Gourgoulianis, Konstantinos

    2015-08-01

    The effects of Non-invasive Ventilation (NIV) on Insulin Resistance (IR) in stable Chronic Obstructive Pulmonary Disease (COPD) patients have not been fully explored. The aim of this study was to assess the effects of NIV on IR and adiponectin levels during one year application of NIV in stable COPD patients with Chronic Hypercapnic Respiratory Failure. Twenty-five (25) stable COPD patients with Chronic Hypercapnic Respiratory Failure and with no self-reported comorbidities completed the study. NIV was administered in the spontaneous/timed mode via a full face mask using a bi-level positive airway pressure system. Spirometry, blood pressure, arterial blood gases, dyspnea, daytime sleepiness, serum fasting glucose and insulin levels were assessed. IR was assessed with the calculation of the Homeostatic Model Assessment (HOMA) index. Adiponectin was measured with radioimmunoassay. Study participants were re-evaluated on the first, third, sixth, ninth and twelfth month after the initial evaluation. There was a significant improvement in FEV1 values from the first month (34.1 ± 11.6% vs 37 ± 12.3%, p = 0.05). There was a significant decrease in IR by the ninth month of NIV use (3.4 ± 2.3 vs 2.2 ± 1.4, p < 0.0001), while adiponectin levels significantly improved from the first month of NIV use. Stepwise regression analysis revealed that baseline HOMA index was associated with paCO2 (β = 0.07 ± 0.02, p = 0.001), while baseline adiponectin levels were associated with FVC (β = 0.05 ± 0.02, p = 0.035) and the concentration of serum bicarbonate (HCO3-) (-β = 0.18 ± 0.06, p = 0.002). Insulin sensitivity and glucose metabolism as well as adiponectin levels improved along with the improvements in respiratory failure.

  18. Biomedical Instruments for Fetal and Neonatal Surveillance

    NASA Astrophysics Data System (ADS)

    Rolfe, P.; Scopesi, F.; Serra, G.

    2006-10-01

    Specialised instruments have been developed to aid the care of the fetus and the newborn baby. Miniature sensors using optical, electrical, chemical, mechanical and magnetic principles have been produced for capturing key measurands. These include temperature, pressure, flow and dimension, as well as several specific molecules such as glucose, oxygen and carbon dioxide. During pregnancy ultrasound imaging and blood flow techniques provide valuable information concerning fetal abnormalities, fetal growth, fetal breathing and fetal heart rate. Signal processing and pattern recognition can be useful for deriving indicators of fetal distress and clinical status, based on biopotentials as well as ultrasound signals. Fetal pH measurement is a critical requirement during labour and delivery. The intensive care of ill preterm babies involves provision of an optimal thermal environment and respiratory support. Monitoring of blood gas and acid-base status is essential, and this involves both blood sampling for in vitro analysis as well as the use of invasive or non-invasive sensors. For the future it will be vital that the technologies used are subjected to controlled trials to establish benefit or otherwise.

  19. Monitoring internal organ motion with continuous wave radar in CT.

    PubMed

    Pfanner, Florian; Maier, Joscha; Allmendinger, Thomas; Flohr, Thomas; Kachelrieß, Marc

    2013-09-01

    To avoid motion artifacts in medical imaging or to minimize the exposure of healthy tissues in radiation therapy, medical devices are often synchronized with the patient's respiratory motion. Today's respiratory motion monitors require additional effort to prepare the patients, e.g., mounting a motion belt or placing an optical reflector on the patient's breast. Furthermore, they are not able to measure internal organ motion without implanting markers. An interesting alternative to assess the patient's organ motion is continuous wave radar. The aim of this work is to design, implement, and evaluate such a radar system focusing on application in CT. The authors designed a radar system operating in the 860 MHz band to monitor the patient motion. In the intended application of the radar system, the antennas are located close to the patient's body inside the table of a CT system. One receive and four transmitting antennas are used to avoid the requirement of exact patient positioning. The radar waves propagate into the patient's body and are reflected at tissue boundaries, for example at the borderline between muscle and adipose tissue, or at the boundaries of organs. At present, the authors focus on the detection of respiratory motion. The radar system consists of the hardware mentioned above as well as of dedicated signal processing software to extract the desired information from the radar signal. The system was evaluated using simulations and measurements. To simulate the radar system, a simulation model based on radar and wave field equations was designed and 4D respiratory-gated CT data sets were used as input. The simulated radar signals and the measured data were processed in the same way. The radar system hardware and the signal processing algorithms were tested with data from ten volunteers. As a reference, the respiratory motion signal was recorded using a breast belt simultaneously with the radar measurements. Concerning the measurements of the test persons, there is a very good correlation (ρ = 0.917) between the respiratory motion phases received by the radar system and the external motion monitor. Our concept of using an array of transmitting antennas turned out to be widely insensitive to the positioning of the test persons. A time shift between the respiratory motion curves recorded with the radar system and the motion curves from the external respiratory monitor was observed which indicates a slight difference between internal organ motion and motion detected by the external respiratory monitor. The simulations were in good accordance with the measurements. A continuous wave radar operating in the near field of the antennas can be used to determine the respiratory motion of humans accurately. In contrast to trigger systems used today, the radar system is able to measure motion inside the body. If such a monitor was routinely available in clinical CT, it would be possible optimizing the scan start with respect to the respiratory state of the patient. Breathing commands would potentially widely be avoided, and as far as uncooperative patients or children are concerned, less sedation might be necessary. Further applications of the radar system could be in radiation therapy or interventional imaging for instance.

  20. Noninvasive monitoring of treatment response in a rabbit cyanide toxicity model reveals differences in brain and muscle metabolism

    NASA Astrophysics Data System (ADS)

    Kim, Jae G.; Lee, Jangwoen; Mahon, Sari B.; Mukai, David; Patterson, Steven E.; Boss, Gerry R.; Tromberg, Bruce J.; Brenner, Matthew

    2012-10-01

    Noninvasive near infrared spectroscopy measurements were performed to monitor cyanide (CN) poisoning and recovery in the brain region and in foreleg muscle simultaneously, and the effects of a novel CN antidote, sulfanegen sodium, on tissue hemoglobin oxygenation changes were compared using a sub-lethal rabbit model. The results demonstrated that the brain region is more susceptible to CN poisoning and slower in endogenous CN detoxification following exposure than peripheral muscles. However, sulfanegen sodium rapidly reversed CN toxicity, with brain region effects reversing more quickly than muscle. In vivo monitoring of multiple organs may provide important clinical information regarding the extent of CN toxicity and subsequent recovery, and facilitate antidote drug development.

  1. NON-INVASIVE MONITORING OF FOETAL ANAEMIA IN KELL SENSITIZED PREGNANCY.

    PubMed

    Memon, Zaibunnisa; Sheikh, Sana Sadiq

    2015-01-01

    We report a case of Kell sensitized pregnancy with good neonatal outcome. Anti-K antibodies were detected in maternal serum in early pregnancy as a part of routine antibody screening test. The middle cerebral artery doppler monitoring and serial titers were carried out to screen for foetal anaemia. Despite of rising antibody titers, serial middle cerebral artery doppler was normal and did not showed foetal anaemia. The pregnancy was carried out till term and patient delivered at 37 weeks of pregnancy with no evidence of foetal anaemia. This case underlines the need of general screening on rare antibodies in all pregnant women and that non-invasive monitoring of foetal anaemia can be done with anti-k titers and middle cerebral artery Doppler.

  2. Limitations of Stroke Volume Estimation by Non-Invasive Blood Pressure Monitoring in Hypergravity

    PubMed Central

    2015-01-01

    Background Altitude and gravity changes during aeromedical evacuations induce exacerbated cardiovascular responses in unstable patients. Non-invasive cardiac output monitoring is difficult to perform in this environment with limited access to the patient. We evaluated the feasibility and accuracy of stroke volume estimation by finger photoplethysmography (SVp) in hypergravity. Methods Finger arterial blood pressure (ABP) waveforms were recorded continuously in ten healthy subjects before, during and after exposure to +Gz accelerations in a human centrifuge. The protocol consisted of a 2-min and 8-min exposure up to +4 Gz. SVp was computed from ABP using Liljestrand, systolic area, and Windkessel algorithms, and compared with reference values measured by echocardiography (SVe) before and after the centrifuge runs. Results The ABP signal could be used in 83.3% of cases. After calibration with echocardiography, SVp changes did not differ from SVe and values were linearly correlated (p<0.001). The three algorithms gave comparable SVp. Reproducibility between SVp and SVe was the best with the systolic area algorithm (limits of agreement −20.5 and +38.3 ml). Conclusions Non-invasive ABP photoplethysmographic monitoring is an interesting technique to estimate relative stroke volume changes in moderate and sustained hypergravity. This method may aid physicians for aeronautic patient monitoring. PMID:25798613

  3. Evaluation of the overall efficacy of the Omron office digital blood pressure HEM-907 monitor in adults.

    PubMed

    White, W B; Anwar, Y A

    2001-04-01

    Non-invasive self blood pressure monitoring has become increasingly popular. To assure the accuracy of devices used for this purpose, all need to be validated independently prior to marketing. The objective of this study was to assess the accuracy of the HEM-907, a new semi-automatic, non-invasive, oscillometric blood pressure monitoring device specifically designed to be used in the clinic or physician's office setting. Blood pressure measurements taken employing this device were compared with the results obtained by two experienced observers using a mercury sphygmomanometer on 100 subjects and patients (384 measurements). The limits of agreement were calculated for the device compared with the results of the two observers according to the standards of the Association for the Advancement of Medical Instrumentation (AAMI). The agreement between the two observers was -0.36+/-2.32mmHg for systolic blood pressure and 0.02+/-2.42mmHg for diastolic blood pressure. The agreement between the device and the observers was 1.56+/-4.42mmHg and 3.49+/-4.61mmHg for systolic and diastolic blood pressure respectively. The Omron HEM-907 satisfied the AAMI criteria for accuracy for a non-invasive blood pressure monitoring device.

  4. Non-invasive monitoring of hemodynamic changes in orthotropic brain tumor

    NASA Astrophysics Data System (ADS)

    Kashyap, Dheerendra; Sharma, Vikrant; Liu, Hanli

    2007-02-01

    Radio surgical interventions such as Gamma Knife and Cyberknife have become attractive as therapeutic interventions. However, one of the drawbacks of cyberknife is radionecrosis, which is caused by excessive radiation to surrounding normal tissues. Radionecrosis occurs in about 10-15% of cases and could have adverse effects leading to death. Currently available imaging techniques have failed to reliably distinguish radionecrosis from tumor growth. Development of imaging techniques that could provide distinction between tumor growth and radionecrosis would give us ability to monitor effects of radiation therapy non-invasively. This paper investigates the use of near infrared spectroscopy (NIRS) as a new technique to monitor the growth of brain tumors. Brain tumors (9L glioma cell line) were implanted in right caudate nucleus of rats (250-300 gms, Male Fisher C) through a guide screw. A new algorithm was developed, which used broadband steady-state reflectance measurements made using a single source-detector pair, to quantify absolute concentrations of hemoglobin derivatives and reduced scattering coefficients. Preliminary results from the brain tumors indicated decreases in oxygen saturation, oxygenated hemoglobin concentrations and increases in deoxygenated hemoglobin concentrations with tumor growth. The study demonstrates that NIRS technology could provide an efficient, noninvasive means of monitoring vascular oxygenation dynamics of brain tumors and further facilitate investigations of efficacy of tumor treatments.

  5. Noninvasive NIR measurement of tissue pH to assess hemorrhagic shock in swine

    NASA Astrophysics Data System (ADS)

    Soller, Babs R.; Zhang, Songbiao; Micheels, Ronald H.; Puyana, Juan C.

    1999-07-01

    Body-worn noninvasive physilogical sensors are needed to continuously monitor soldiers for hemorrhage and to provide real-time information for minimally skilled medics to treat the injured. In the hospital intramucosal pHi of the gut is used to monitor shock and its treatment. We hypothesize that abdominal wall muscle (AWM) pH can be measured noninvasively using near infrared (NIR) spectroscopy and partial least squares analysis (PLS) and will correlate with pHi. METHODS: AWM pH was measured with microelectrodes and gastric pHi was measured with a tonometric catheter simultaneously while NIR spectra were collected using prototype LED spectrometers placed on the pig's flanks. Animals were subject to hemorrhagic shock at 45 mm Hg for 45 minutes, then resuscitated with blood and lactated ringers. Relationships between electrode pH, pHi and NIR spectra were developed using PLS with cross validation. RESULTS: NIR spectral changes noninvasively acquired through the skin were shown to be from the muscle, not from changes in skin blood flow. Trending ability (R2) model accuracy (RMSD), and relative error were calculated for individual pigs. Using electrode pH as the reference, average R2 was 0.88 with a predicted accuracy of 0.17 pH units, a 9.3% relative error. Slightly degraded results were observed when pHi was used as a reference. CONCLUSIONS: NIR measurement of tissue pH can be used to noninvasively monitor for shock and guide its treatment in a swine model. These measurements correlate with gastric pHi, a clinically accepted measure of shock, providing an approach to develop similar methodology for humans.

  6. Noninvasive Real-Time Assessment of Cell Viability in a Three-Dimensional Tissue.

    PubMed

    Mahfouzi, Seyed Hossein; Amoabediny, Ghassem; Doryab, Ali; Safiabadi-Tali, Seyed Hamid; Ghanei, Mostafa

    2018-04-01

    Maintaining cell viability within 3D tissue engineering scaffolds is an essential step toward a functional tissue or organ. Assessment of cell viability in 3D scaffolds is necessary to control and optimize tissue culture process. Monitoring systems based on respiration activity of cells (e.g., oxygen consumption) have been used in various cell cultures. In this research, an online monitoring system based on respiration activity was developed to monitor cell viability within acellular lung scaffolds. First, acellular lung scaffolds were recellularized with human umbilical cord vein endothelial cells, and then, cell viability was monitored during a 5-day period. The real-time monitoring system generated a cell growth profile representing invaluable information on cell viability and proliferative states during the culture period. The cell growth profile obtained by the monitoring system was consistent with 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide analysis and glucose consumption measurement. This system provided a means for noninvasive, real-time, and repetitive investigation of cell viability. Also, we showed the applicability of this monitoring system by introducing shaking as an operating parameter in a long-term culture.

  7. Lung Function Measurements in Rodents in Safety Pharmacology Studies

    PubMed Central

    Hoymann, Heinz Gerd

    2012-01-01

    The ICH guideline S7A requires safety pharmacology tests including measurements of pulmonary function. In the first step – as part of the “core battery” – lung function tests in conscious animals are requested. If potential adverse effects raise concern for human safety, these should be explored in a second step as a “follow-up study”. For these two stages of safety pharmacology testing, both non-invasive and invasive techniques are needed which should be as precise and reliable as possible. A short overview of typical in vivo measurement techniques is given, their advantages and disadvantages are discussed and out of these the non-invasive head-out body plethysmography and the invasive but repeatable body plethysmography in orotracheally intubated rodents are presented in detail. For validation purposes the changes in the respective parameters such as tidal midexpiratory flow (EF50) or lung resistance have been recorded in the same animals in typical bronchoconstriction models and compared. In addition, the technique of head-out body plethysmography has been shown to be useful to measure lung function in juvenile rats starting from day two of age. This allows safety pharmacology testing and toxicological studies in juvenile animals as a model for the young developing organism as requested by the regulatory authorities (e.g., EMEA Guideline 1/2008). It is concluded that both invasive and non-invasive pulmonary function tests are capable of detecting effects and alterations on the respiratory system with different selectivity and area of operation. The use of both techniques in a large number of studies in mice and rats in the last years have demonstrated that they provide useful and reliable information on pulmonary mechanics in safety pharmacology and toxicology testing, in investigations of respiratory disorders, and in pharmacological efficacy studies. PMID:22973226

  8. 21 CFR 868.2480 - Cutaneous carbon dioxide (PcCO 2) monitor.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Cutaneous carbon dioxide (PcCO 2) monitor. 868... dioxide (PcCO 2) monitor. (a) Identification. A cutaneous carbon dioxide (PcCO2) monitor is a noninvasive... relative changes in a hemodynamically stable patient's cutaneous carbon dioxide tension as an adjunct to...

  9. 21 CFR 868.2480 - Cutaneous carbon dioxide (PcCO 2) monitor.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Cutaneous carbon dioxide (PcCO 2) monitor. 868... dioxide (PcCO 2) monitor. (a) Identification. A cutaneous carbon dioxide (PcCO2) monitor is a noninvasive... relative changes in a hemodynamically stable patient's cutaneous carbon dioxide tension as an adjunct to...

  10. A patient self-collection method for longitudinal monitoring of respiratory virus infection in solid organ transplant recipients.

    PubMed

    Preiksaitis, Carl M; Kuypers, Jane M; Fisher, Cynthia E; Campbell, Angela P; Jerome, Keith R; Huang, Meei-Li; Boeckh, Michael; Limaye, Ajit P

    2015-01-01

    Methods for the longitudinal study of respiratory virus infections are cumbersome and limit our understanding of the natural history of these infections in solid organ transplant (SOT) recipients. To assess the feasibility and patient acceptability of self-collected foam nasal swabs for detection of respiratory viruses in SOT recipients and to define the virologic and clinical course. We prospectively monitored the course of symptomatic respiratory virus infection in 18 SOT patients (14 lung, 3 liver, and 1 kidney) using patient self-collected swabs. The initial study sample was positive in 15 patients with the following respiratory viruses: rhinovirus (6), metapneumovirus (1), coronavirus (2), respiratory syncytial virus (2), parainfluenza virus (2), and influenza A virus (2). One hundred four weekly self-collected nasal swabs were obtained, with a median of 4 samples per patient (range 1-17). Median duration of viral detection was 21 days (range 4-77 days). Additional new respiratory viruses detected during follow-up of these 15 patients included rhinovirus (3), metapneumovirus (2), coronavirus (1), respiratory syncytial virus (1), parainfluenza virus (1), and adenovirus (1). Specimen collection compliance was good; 16/18 (89%) patients collected all required specimens and 79/86 (92%) follow-up specimens were obtained within the 7 ± 3 day protocol-defined window. All participants agreed or strongly agreed that the procedure was comfortable, simple, and 13/14 (93%) were willing to participate in future studies using this procedure. Self-collected nasal swabs provide a convenient, feasible, and patient-acceptable methodology for longitudinal monitoring of upper respiratory virus infection in SOT recipients. Copyright © 2014 Elsevier B.V. All rights reserved.

  11. Non-invasive blood glucose monitor based on spectroscopy using a smartphone.

    PubMed

    Dantu, Vishnu; Vempati, Jagannadh; Srivilliputhur, Srinivasan

    2014-01-01

    Development of a novel method for non-invasive measurement of blood glucose concentration using smartphone is discussed. Our research work has three major contributions to society and science. First, we modified and extended the Beer-Lambert's law in physics to accommodate for multiple wavelengths. This extension can aid researchers who wish to perform optical spectroscopy. Second, we successfully developed a creative and non-invasive way for diabetic patients to measure glucose levels via a smartphone. Researchers and chemists can now use their smartphones to determine the absorbance and, therefore, concentration of a chemical. Third, we created an inexpensive way to perform optical spectroscopy by using a smartphone. Monitoring blood glucose using a smartphone application that simply uses equipment already available on smartphones will improve the lives of diabetic patients who can continuously check their blood glucose levels while avoiding the current inconvenient, unhygienic, and costly invasive glucose meters.

  12. Non-invasive imaging using reporter genes altering cellular water permeability

    NASA Astrophysics Data System (ADS)

    Mukherjee, Arnab; Wu, Di; Davis, Hunter C.; Shapiro, Mikhail G.

    2016-12-01

    Non-invasive imaging of gene expression in live, optically opaque animals is important for multiple applications, including monitoring of genetic circuits and tracking of cell-based therapeutics. Magnetic resonance imaging (MRI) could enable such monitoring with high spatiotemporal resolution. However, existing MRI reporter genes based on metalloproteins or chemical exchange probes are limited by their reliance on metals or relatively low sensitivity. Here we introduce a new class of MRI reporters based on the human water channel aquaporin 1. We show that aquaporin overexpression produces contrast in diffusion-weighted MRI by increasing tissue water diffusivity without affecting viability. Low aquaporin levels or mixed populations comprising as few as 10% aquaporin-expressing cells are sufficient to produce MRI contrast. We characterize this new contrast mechanism through experiments and simulations, and demonstrate its utility in vivo by imaging gene expression in tumours. Our results establish an alternative class of sensitive, metal-free reporter genes for non-invasive imaging.

  13. Noninvasive Intracranial Volume and Pressure Measurements Using Ultrasound

    NASA Technical Reports Server (NTRS)

    Hargens, A. R.

    1998-01-01

    Prevention of secondary brain injuries following head can be accomplished most easily when intracranial pressure (ICP) is monitored. However, current measurement techniques are invasive and thus not practical in the combat environment. The Pulsed Phase Lock Loop (PPLL) devise, which was developed and patented, uses a unique, noninvasive ultrasonic phase comparison method to measure slight changes in cranial volume which occur with changes in ICP. Year one studies involved instrument improvements and measurement of altered intracranial distance with altered ICP in fresh cadavera. Our software was improved to facilitate future studies of normal subjects and trauma patients. Our bench studies proved that PPLL output correlated highly with changes in path length across a model cranium. Cadaveric studies demonstrated excellent compact, noninvasive devise for monitoring changes in intracranial distance may aid in the early detection of elevated ICP, decreasing risk of secondary brain injury and infection, and returning head-injured patients to duty.

  14. Head space analysis to non-invasively distinguish between vaccinated and bovine tuberculosis-infected white-tailed deer

    USDA-ARS?s Scientific Manuscript database

    White-tailed deer (WTD; Odocoileus virginianus) can act as a reservoir for bovine tuberculosis (bTB), caused by Mycobacterium bovis, and can be a source of infection in cattle. Presently, no method exists to noninvasively monitor the presence of bTB in wildlife. In addition, due to similarities betw...

  15. Mechanical Ventilation and Bronchopulmonary Dysplasia.

    PubMed

    Keszler, Martin; Sant'Anna, Guilherme

    2015-12-01

    Mechanical ventilation is an important potentially modifiable risk factor for the development of bronchopulmonary dysplasia. Effective use of noninvasive respiratory support reduces the risk of lung injury. Lung volume recruitment and avoidance of excessive tidal volume are key elements of lung-protective ventilation strategies. Avoidance of oxidative stress, less invasive methods of surfactant administration, and high-frequency ventilation are also important factors in lung injury prevention. Copyright © 2015 Elsevier Inc. All rights reserved.

  16. Consortia for Improving Medicine with Innovation and Technology

    DTIC Science & Technology

    2016-12-01

    2011 Out - 001585 11-484 Award Closed Hacking, Adam Non-invasive Fasciotomy to Treat Extremity Compartment Syndrome 2012 Out - 001706 12-1173 Award...592 Award Closed 7 Kaushal, Shalesh Low Energy Laser as a Therapeutic for Dry Age-related Macular Degeneration 2011 Out - 001607 11-397 Award Closed...Electrostatic dry powder inhaler for constant dose respiratory drug delivery 2010 Out - 000885 10-512 Award Closed McLaughlin, Bryan An implantable

  17. Systematic review of non-invasive positive pressure ventilation for chronic respiratory failure.

    PubMed

    Hannan, Liam M; Dominelli, Giulio S; Chen, Yi-Wen; Darlene Reid, W; Road, Jeremy

    2014-02-01

    This systematic review examined the effect of non-invasive positive pressure ventilation (NIPPV) on patient reported outcomes (PROs) and survival for individuals with or at risk of chronic respiratory failure (CRF). Randomised controlled trials (RCTs) and prospective non-randomised studies in those treated with NIPPV for CRF were identified from electronic databases, reference lists and grey literature. Diagnostic groups included in the review were amyotrophic lateral sclerosis/motor neuron disease (ALS/MND), Duchenne muscular dystrophy (DMD), restrictive thoracic disease (RTD) and obesity hypoventilation syndrome (OHS). Eighteen studies were included and overall study quality was weak. Those with ALS/MND had improved somnolence and fatigue as well as prolonged survival with NIPPV. For OHS, improvements in somnolence and fatigue, dyspnoea and sleep quality were demonstrated, while for RTD, measures of dyspnoea, sleep quality, physical function and health, mental and emotional health and social function improved. There was insufficient evidence to form conclusions regarding the effect of NIPPV for those with DMD. This review has demonstrated that NIPPV influences PROs differently depending on the underlying cause of CRF. These findings may provide assistance to patients and clinicians to determine the relative costs and benefits of NIPPV therapy and also highlight areas in need of further research. Copyright © 2013 Elsevier Ltd. All rights reserved.

  18. Influence of mouth opening on oropharyngeal humidification and temperature in a bench model of neonatal continuous positive airway pressure.

    PubMed

    Fischer, Hendrik S; Ullrich, Tim L; Bührer, Christoph; Czernik, Christoph; Schmalisch, Gerd

    2017-02-01

    Clinical studies show that non-invasive respiratory support by continuous positive airway pressure (CPAP) affects gas conditioning in the upper airways, especially in the presence of mouth leaks. Using a new bench model of neonatal CPAP, we investigated the influence of mouth opening on oropharyngeal temperature and humidity. The model features the insertion of a heated humidifier between an active model lung and an oropharyngeal head model to simulate the recurrent expiration of heated, humidified air. During unsupported breathing, physiological temperature and humidity were attained inside the model oropharynx, and mouth opening had no significant effect on oropharyngeal temperature and humidity. During binasal CPAP, the impact of mouth opening was investigated using three different scenarios: no conditioning in the CPAP circuit, heating only, and heated humidification. Mouth opening had a strong negative impact on oropharyngeal humidification in all tested scenarios, but heated humidification in the CPAP circuit maintained clinically acceptable humidity levels regardless of closed or open mouths. The model can be used to test new equipment for use with CPAP, and to investigate the effects of other methods of non-invasive respiratory support on gas conditioning in the presence of leaks. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  19. Factors predicting survival following noninvasive ventilation in amyotrophic lateral sclerosis.

    PubMed

    Peysson, S; Vandenberghe, N; Philit, F; Vial, C; Petitjean, T; Bouhour, F; Bayle, J Y; Broussolle, E

    2008-01-01

    The involvement of respiratory muscles is a major predicting factor for survival in amyotrophic lateral sclerosis (ALS). Recent studies show that noninvasive ventilation (NIV) can relieve symptoms of alveolar hypoventilation. However, factors predicting survival in ALS patients when treated with NIV need to be clarified. We conducted a retrospective study of 33 consecutive ALS patients receiving NIV. Ten patients had bulbar onset. We determined the median survivals from onset, diagnosis and initiation of NIV and factors predicting survival. Statistical analysis was performed using the Kaplan-Meier test and Cox proportional hazard models. The median initial and maximal total uses of NIV were 10 and 14 h/24h. The overall median survival from ALS onset was 34.2 months and worsened with increasing age and bulbar onset of the disease. The median survival from initiation of NIV was 8.4 months and was significantly poorer in patients with advanced age or with airway mucus accumulation. Survival from initiation of NIV was not influenced by respiratory parameters or bulbar symptoms. Advanced age at diagnosis and airway mucus accumulation represent poorer prognostic factors of ALS patients treated with NIV. NIV is a helpful treatment of sleep-disordered breathing, including patients with bulbar involvement. Copyright 2008 S. Karger AG, Basel.

  20. The avian respiratory system: a unique model for studies of respiratory toxicosis and for monitoring air quality.

    PubMed Central

    Brown, R E; Brain, J D; Wang, N

    1997-01-01

    There are many distinct differences (morphologic, physiologic, and mechanical) between the bird's lung-air-sac respiratory system and the mammalian bronchoalveolar lung. In this paper, we review the physiology of the avian respiratory system with attention to those mechanisms that may lead to significantly different results, relative to those in mammals, following exposure to toxic gases and airborne particulates. We suggest that these differences can be productively exploited to further our understanding of the basic mechanisms of inhalant toxicology (gases and particulates). The large mass-specific gas uptake by the avian respiratory system, at rest and especially during exercise, could be exploited as a sensitive monitor of air quality. Birds have much to offer in our understanding of respiratory toxicology, but that expectation can only be realized by investigating, in a wide variety of avian taxa, the pathophysiologic interactions of a broad range of inhaled toxicants on the bird's unique respiratory system. Images p188-a Figure 1. Figure 2. Figure 3. Figure 4. Figure 5. A Figure 5. B Figure 5. C Figure 6. Figure 7. Figure 8. PMID:9105794

  1. TH-AB-202-07: Radar Tracking of Respiratory Motion in Real Time

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fung, A; Li, C; Torres, C

    Purpose: To propose a method of real time tracking of respiratory motion in patients undergoing radiation therapy. Radar technology can be employed to detection the movement of diaphragm and thoracic anatomy. Methods: A radar transceiver was specially designed. During experiment, the radar device was securely attached to a fixed frame. Respiratory motion was simulated with: 1) Varian RPM phantom, 2) Standard Imaging Respiratory Gating Platform. Signals recorded with radar equipment were compared with those measured with Varian RPM system as a reference. Results: Motion generated by Varian RPM phantom was recorded by the radar device, and compared to the signalsmore » recorded by RPM camera. The results showed exact agreement between the two monitoring equipments. Motion was also generated by Standard Imaging Respiratory Motion Platform. The results showed the radar device was capable of measuring motion of various amplitudes and periods. Conclusion: The proposed radar device is able to measure movements such as respiratory motion. Compared to state-of-the-art respiratory detection instrument, the radar device is shown to be equally precise and effective for monitoring respiration in radiation oncology patients.« less

  2. Continuous Positive Airway Pressure Strategies with Bubble Nasal Continuous Positive Airway Pressure: Not All Bubbling Is the Same: The Seattle Positive Airway Pressure System.

    PubMed

    Welty, Stephen E

    2016-12-01

    Premature neonates are predisposed to complications, including bronchopulmonary dysplasia (BPD). BPD is associated with long-term pulmonary and neurodevelopmental consequences. Noninvasive respiratory support with nasal continuous positive airway pressure (CPAP) has been recommended strongly by the American Academy of Pediatrics. However, CPAP implementation has shown at least a 50% failure rate. Enhancing nasal CPAP effectiveness may decrease the need for mechanical ventilation and reduce the incidence of BPD. Bubble nasal CPAP is better than nasal CPAP using mechanical devices and the bubbling provides air exchange in distal respiratory units. The Seattle PAP system reduces parameters that assess work of breathing. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. [A non-invasive portable blood-glucose monitoring system: sampling of suction effusion fluid].

    PubMed

    Arai, T; Kayashima, S; Kikuchi, M; Kaneyoshi, A; Itoh, N

    1995-04-01

    We developed a new portable transcutaneous blood glucose monitoring system using non-invasive collection of suction effusion fluid (SEF) from human skin. A ion sensitive field effect transistor (ISFET) sensor was employed to measure glucose concentration in a very small quantity of the SEF. The system was composed of a couple of portions. One structure was a suction cell, and the other was a main frame. The suction cell included the ISFET glucose sensor, a dilution mechanism, and a sucking interface to human skin. The main frame contained a dilution solution reservoir, a liquid waste reservoir, a fluid pump, a vacuum pump, a micro processor, batteries, and a user interface. The system is self-contained for portable usage during up to 6 hrs monitoring. This system may be the first blood glucose monitoring equipment which does not use blood sampling.

  4. Comparison of Non-Invasive Individual Monitoring of the Training and Health of Athletes with Commercially Available Wearable Technologies

    PubMed Central

    Düking, Peter; Hotho, Andreas; Holmberg, Hans-Christer; Fuss, Franz Konstantin; Sperlich, Billy

    2016-01-01

    Athletes adapt their training daily to optimize performance, as well as avoid fatigue, overtraining and other undesirable effects on their health. To optimize training load, each athlete must take his/her own personal objective and subjective characteristics into consideration and an increasing number of wearable technologies (wearables) provide convenient monitoring of various parameters. Accordingly, it is important to help athletes decide which parameters are of primary interest and which wearables can monitor these parameters most effectively. Here, we discuss the wearable technologies available for non-invasive monitoring of various parameters concerning an athlete's training and health. On the basis of these considerations, we suggest directions for future development. Furthermore, we propose that a combination of several wearables is most effective for accessing all relevant parameters, disturbing the athlete as little as possible, and optimizing performance and promoting health. PMID:27014077

  5. Noninvasive ergonovine maleate provocative testing for coronary artery spasm: the need for routine thallium-201 imaging

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shanes, J.G.; Krone, R.J.; Fisher, K.

    1983-01-01

    We administered ergonovine and used both electrocardiographic monitoring and thallium-/sup 201/ (/sup 201/Tl) imaging to detect reversible ischemia in 100 patients. Patients already established as having coronary artery spasm and those with nonbypassed, proximal, high-grade coronary artery stenosis were excluded. No complication occurred in any patient. The use of thallium imaging in addition to electrocardiographic monitoring resulted in a higher degree of sensitivity than did ECG monitoring alone. Fourteen patients demonstrated evidence of coronary artery spasm as documented by /sup 201/Tl imaging but of the 14, significant ECG changes occurred in only 50%, and classic ST segment elevation in 21%.more » Thus, in carefully selected patients the noninvasive provocation of coronary spasm can be accomplished safely, but ECG monitoring must be combined with thallium-/sup 201/ imaging to achieve an acceptable degree of sensitivity.« less

  6. Non-invasive ventilation after surgery in amyotrophic lateral sclerosis.

    PubMed

    Olivieri, C; Castioni, C A; Livigni, S; Bersano, E; Cantello, R; Della Corte, F; Mazzini, L

    2014-04-01

    Surgery in patients affected by amyotrophic lateral sclerosis (ALS) presents a particular anesthetic challenge because of the risk of post-operative pulmonary complications. We report on the use of non-invasive ventilation (NIV) to prevent post-operative pulmonary complications (PPCs) in nine patients affected by ALS enrolled in a phase-1 clinical trial with stem cell transplantation. All patients were treated with autologous mesenchymal stem cells implanted into the spinal cord with a surgical procedure. Anesthesia was induced with propofol and maintained with remifentanil and sevoflurane. No muscle relaxant was used. After awakening and regain of spontaneous breathing, patients were tracheally extubated. Non-invasive ventilation through nasal mask was delivered and non-invasive positive pressure ventilation and continuous positive pressure ventilation were started. The average time on NIV after surgery was 3 h and 12 min. All patients regained stable spontaneous breathing after NIV discontinuation and had no episodes of respiratory failure until the following day. Our case series suggest that the use of NIV after surgery can be a safe strategy to prevent PPCs in patients affected by ALS. The perioperative procedure we chose for these patients appeared safe even in patients with advanced functional stage of the disease. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  7. Advanced positive airway pressure modes: adaptive servo ventilation and volume assured pressure support.

    PubMed

    Selim, Bernardo; Ramar, Kannan

    2016-09-01

    Volume assured pressure support (VAPS) and adaptive servo ventilation (ASV) are non-invasive positive airway pressure (PAP) modes with sophisticated negative feedback control systems (servomechanism), having the capability to self-adjust in real time its respiratory controlled variables to patient's respiratory fluctuations. However, the widespread use of VAPS and ASV is limited by scant clinical experience, high costs, and the incomplete understanding of propriety algorithmic differences in devices' response to patient's respiratory changes. Hence, we will review and highlight similarities and differences in technical aspects, control algorithms, and settings of each mode, focusing on the literature search published in this area. One hundred twenty relevant articles were identified by Scopus, PubMed, and Embase databases from January 2010 to 2016, using a combination of MeSH terms and keywords. Articles were further supplemented by pearling. Recommendations were based on the literature review and the authors' expertise in this area. Expert commentary: ASV and VAPS differ in their respiratory targets and response to a respiratory fluctuation. The VAPS mode targets a more consistent minute ventilation, being recommended in the treatment of sleep related hypoventilation disorders, while ASV mode attempts to provide a more steady breathing airflow pattern, treating successfully most central sleep apnea syndromes.

  8. Kenny Caffey syndrome with severe respiratory and gastrointestinal involvement: expanding the clinical phenotype

    PubMed Central

    Christodoulou, Loucas; Krishnaiah, Anil; Spyridou, Christina; Salpietro, Vincenzo; Hannan, Siobhan; Saggar, Anand; Mankad, Kshitij; Deep, Akash

    2015-01-01

    Kenny Caffey syndrome (KCS) is a rare syndrome reported almost exclusively in Middle Eastern populations. It is characterized by severe growth retardation—short stature, dysmorphic features, episodic hypocalcaemia, hypoparathyroidism, seizures, and medullary stenosis of long bones with thickened cortices. We report a 10-year-old boy with KCS with an unusually severe respiratory and gastrointestinal system involvement—features not previously described in the literature. He had severe psychomotor retardation and regressed developmentally from walking unaided to sitting with support. MRI brain showed bilateral hippocampal sclerosis, marked supra-tentorial volume loss and numerous calcifications. A 12 bp deletion of exon 2 of tubulin-specific chaperone E (TBCE) gene was identified and the diagnosis of KCS was confirmed. Hypercarbia following a sleep study warranted nocturnal continuous positive airway pressure (CPAP) when aged 6. When boy aged 8, persistent hypercarbia with increasing oxygen requirement and increased frequency and severity of lower respiratory tract infections led to progressive respiratory failure. He became fully dependent on non-invasive ventilation and by 9 years he had a tracheotomy and was established on long-term ventilation. He developed retching, vomiting and diarrhea. Chest CT showed changes consistent with chronic aspiration, but no interstitial pulmonary fibrosis. He died aged 10 from respiratory complications. PMID:26029652

  9. Kenny Caffey syndrome with severe respiratory and gastrointestinal involvement: expanding the clinical phenotype.

    PubMed

    Christodoulou, Loucas; Krishnaiah, Anil; Spyridou, Christina; Salpietro, Vincenzo; Hannan, Siobhan; Saggar, Anand; Mankad, Kshitij; Deep, Akash; Kinali, Maria

    2015-06-01

    Kenny Caffey syndrome (KCS) is a rare syndrome reported almost exclusively in Middle Eastern populations. It is characterized by severe growth retardation-short stature, dysmorphic features, episodic hypocalcaemia, hypoparathyroidism, seizures, and medullary stenosis of long bones with thickened cortices. We report a 10-year-old boy with KCS with an unusually severe respiratory and gastrointestinal system involvement-features not previously described in the literature. He had severe psychomotor retardation and regressed developmentally from walking unaided to sitting with support. MRI brain showed bilateral hippocampal sclerosis, marked supra-tentorial volume loss and numerous calcifications. A 12 bp deletion of exon 2 of tubulin-specific chaperone E (TBCE) gene was identified and the diagnosis of KCS was confirmed. Hypercarbia following a sleep study warranted nocturnal continuous positive airway pressure (CPAP) when aged 6. When boy aged 8, persistent hypercarbia with increasing oxygen requirement and increased frequency and severity of lower respiratory tract infections led to progressive respiratory failure. He became fully dependent on non-invasive ventilation and by 9 years he had a tracheotomy and was established on long-term ventilation. He developed retching, vomiting and diarrhea. Chest CT showed changes consistent with chronic aspiration, but no interstitial pulmonary fibrosis. He died aged 10 from respiratory complications.

  10. [Management of acute and severe complications in adults with cystic fibrosis].

    PubMed

    Chapron, J; Zuber, B; Kanaan, R; Hubert, D; Desmazes-Dufeu, N; Mira, J-P; Dusser, D; Burgel, P-R

    2011-04-01

    The natural history of cystic fibrosis (CF) may be associated both with acute respiratory complications (respiratory exacerbations, haemoptysis, pneumothorax) and with non-respiratory complications (distal intestinal obstruction syndrome, dehydration) that may result in hospitalizations. The aim of this article is to describe the main therapeutic approaches that are adopted in the management of acute complications occurring in CF adults, and to discuss indications for admission of these patients to intensive care units. Adult CF patients admitted to intensive care unit often benefit from antibiotic courses adapted to their chronic bronchial infection, especially when the hospitalization is related to respiratory disease (including haemoptysis and pneumothorax). Nutritional support, including hypercaloric diet, control of hyperglycemia and pancreatic enzyme supplementation is warranted. The recommended therapy for major haemoptysis is bronchial artery embolization. Patient with significant pneumothorax should have a chest tube inserted, while the treatment of distal intestinal obstruction syndrome will most often be medical. In case of respiratory failure, non-invasive ventilation is the preferred mode of ventilatory support because invasive ventilation is associated with poor outcomes. Therapeutic options should always have been discussed between the patient, family members and the CF medical team to allow for informed decision making. Copyright © 2011 SPLF. Published by Elsevier Masson SAS. All rights reserved.

  11. Separation of Doppler radar-based respiratory signatures.

    PubMed

    Lee, Yee Siong; Pathirana, Pubudu N; Evans, Robin J; Steinfort, Christopher L

    2016-08-01

    Respiration detection using microwave Doppler radar has attracted significant interest primarily due to its unobtrusive form of measurement. With less preparation in comparison with attaching physical sensors on the body or wearing special clothing, Doppler radar for respiration detection and monitoring is particularly useful for long-term monitoring applications such as sleep studies (i.e. sleep apnoea, SIDS). However, motion artefacts and interference from multiple sources limit the widespread use and the scope of potential applications of this technique. Utilising the recent advances in independent component analysis (ICA) and multiple antenna configuration schemes, this work investigates the feasibility of decomposing respiratory signatures into each subject from the Doppler-based measurements. Experimental results demonstrated that FastICA is capable of separating two distinct respiratory signatures from two subjects adjacent to each other even in the presence of apnoea. In each test scenario, the separated respiratory patterns correlate closely to the reference respiration strap readings. The effectiveness of FastICA in dealing with the mixed Doppler radar respiration signals confirms its applicability in healthcare applications, especially in long-term home-based monitoring as it usually involves at least two people in the same environment (i.e. two people sleeping next to each other). Further, the use of FastICA to separate involuntary movements such as the arm swing from the respiratory signatures of a single subject was explored in a multiple antenna environment. The separated respiratory signal indeed demonstrated a high correlation with the measurements made by a respiratory strap used currently in clinical settings.

  12. Non-invasive glucose monitoring in patients with diabetes: a novel system based on impedance spectroscopy.

    PubMed

    Caduff, A; Dewarrat, F; Talary, M; Stalder, G; Heinemann, L; Feldman, Yu

    2006-12-15

    The aim of this work was to evaluate the performance of a novel non-invasive continuous glucose-monitoring system based on impedance spectroscopy (IS) in patients with diabetes. Ten patients with type 1 diabetes (mean+/-S.D., age 28+/-8 years, BMI 24.2+/-3.2 kg/m(2) and HbA(1C) 7.3+/-1.6%) and five with type 2 diabetes (age 61+/-8 years, BMI 27.5+/-3.2 kg/m(2) and HbA(1C) 8.3+/-1.8%) took part in this study, which comprised a glucose clamp experiment followed by a 7-day outpatient evaluation. The measurements obtained by the NI-CGMD and the reference blood glucose-measuring techniques were evaluated using retrospective data evaluation procedures. Under less controlled outpatient conditions a correlation coefficient of r=0.640 and a standard error of prediction (SEP) of 45 mg dl(-1) with a total of 590 paired glucose measurements was found (versus r=0.926 and a SEP of 26 mg dl(-1) under controlled conditions). Clark error grid analyses (EGA) showed 56% of all values in zone A, 37% in B and 7% in C-E. In conclusion, these results indicate that IS in the used technical setting allows retrospective, continuous and truly non-invasive glucose monitoring under defined conditions for patients with diabetes. Technical advances and developments are needed to expand on this concept to bring the results from the outpatient study closer to those in the experimental section of the study. Further studies will not only help to evaluate the performance and limitations of using such a technique for non non-invasive glucose monitoring but also help to verify technical extensions towards a IS-based concept that offers improved performance under real life operating conditions.

  13. Application of optical lens of a CD writer for detecting the blood glucose semi-invasively

    NASA Astrophysics Data System (ADS)

    Meshram, N. D.; Dahikar, P. B.

    2014-10-01

    Recent technological advancements in the photonics industry have led to a resurgence of interest in optical glucose sensing and to realistic progress toward the development of an optical glucose sensor. Such a sensor has the potential to significantly improve the quality of life for the estimated 16 million diabetics in this country by making routine glucose measurements more convenient. Currently over 100 small companies and universities are working to develop noninvasive or minimally invasive glucose sensing technologies, and optical methods play a large role in these efforts. It has become overwhelmingly clear that frequent monitoring and tight control of blood sugar levels are requisite for effective management of Diabetes mellitus and reduction of the complications associated with this disease. The pain and trouble associated with current "finger-stick" methods for blood glucose monitoring result in decreased patient compliance and a failure to control blood sugar levels. Thus, the development of a convenient noninvasive blood glucose monitor holds the potential to significantly reduce the morbidity and mortality associated with Diabetes. A method and apparatus for noninvasive measurement of blood glucose concentration based on transilluminated laser beam via the Index Finger has been reported in this paper. This method depends on photodiode based laser operating at 632.8 nm wavelength. During measurement, the index finger is inserted into the glucose sensing unit, the transilluminated optical signal is converted into an electrical signal, compared with the reference electrical signal, and the obtained difference signal is processed by signal processing unit which presents the results in the form of blood glucose concentration. This method would enable the monitoring blood glucose level of the diabetic patient continuously, safely and noninvasively..

  14. Non-invasive Monitoring of Intracranial Pressure Using Transcranial Doppler Ultrasonography: Is It Possible?

    PubMed

    Cardim, Danilo; Robba, C; Bohdanowicz, M; Donnelly, J; Cabella, B; Liu, X; Cabeleira, M; Smielewski, P; Schmidt, B; Czosnyka, M

    2016-12-01

    Although intracranial pressure (ICP) is essential to guide management of patients suffering from acute brain diseases, this signal is often neglected outside the neurocritical care environment. This is mainly attributed to the intrinsic risks of the available invasive techniques, which have prevented ICP monitoring in many conditions affecting the intracranial homeostasis, from mild traumatic brain injury to liver encephalopathy. In such scenario, methods for non-invasive monitoring of ICP (nICP) could improve clinical management of these conditions. A review of the literature was performed on PUBMED using the search keywords 'Transcranial Doppler non-invasive intracranial pressure.' Transcranial Doppler (TCD) is a technique primarily aimed at assessing the cerebrovascular dynamics through the cerebral blood flow velocity (FV). Its applicability for nICP assessment emerged from observation that some TCD-derived parameters change during increase of ICP, such as the shape of FV pulse waveform or pulsatility index. Methods were grouped as: based on TCD pulsatility index; aimed at non-invasive estimation of cerebral perfusion pressure and model-based methods. Published studies present with different accuracies, with prediction abilities (AUCs) for detection of ICP ≥20 mmHg ranging from 0.62 to 0.92. This discrepancy could result from inconsistent assessment measures and application in different conditions, from traumatic brain injury to hydrocephalus and stroke. Most of the reports stress a potential advantage of TCD as it provides the possibility to monitor changes of ICP in time. Overall accuracy for TCD-based methods ranges around ±12 mmHg, with a great potential of tracing dynamical changes of ICP in time, particularly those of vasogenic nature.

  15. Non-invasive diagnosis and monitoring of actinic cheilitis with reflectance confocal microscopy.

    PubMed

    Ulrich, M; González, S; Lange-Asschenfeldt, B; Roewert-Huber, J; Sterry, W; Stockfleth, E; Astner, S

    2011-03-01

    Actinic cheilitis (AC) represents the equivalent of actinic keratosis on the lip. Various treatment modalities are available and the efficacy of diclofenac in hyaluronic acid has recently been described. Reflectance confocal microscopy (RCM) is a non-invasive imaging technique which has recently been applied for the diagnosis of actinic keratoses. Herein, we describe the applicability of RCM for the diagnosis of AC and for monitoring of treatment response of AC to diclofenac in hyaluronic acid. Ten Caucasian patients with clinical suspicion for AC were included in this study. To obtain a non-invasive diagnosis, RCM was performed at baseline, followed by biopsy and respective confocal-histopathological correlation. Six patients with a histological diagnosis of AC were treated with diclofenac in hyaluronic acid, whereby monitoring was performed by RCM. Reflectance confocal microscopy was able to correctly identify 6/7 cases of AC and 3/3 cases of benign lesions. The most important RCM criteria for diagnosis of AC were cellular atypia at the stratum spinosum and granulosum with atypical honeycomb pattern. One patient with AC was misclassified as inflammatory cheilitis by RCM as it showed marked inflammatory response and lacked clear signs of cellular atypia on RCM imaging. Following topical treatment with diclofenac gel, 5/6 patients (83%) showed a good treatment response with regression of dysplasia on consecutive RCM examination. Reflectance confocal microscopy is a promising tool for the non-invasive diagnosis and monitoring of actinic cheilitis. However, marked inflammation represents a potential diagnostic pitfall. In this regard, biopsy should be performed in doubtful cases. © 2010 The Authors. Journal of the European Academy of Dermatology and Venereology © 2010 European Academy of Dermatology and Venereology.

  16. Application of optical lens of a CD writer for detecting the blood glucose semi-invasively

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Meshram, N. D., E-mail: meshramnileshsd@gmail.com; Dahikar, P. B., E-mail: pbdahikar@rediffmail.com

    Recent technological advancements in the photonics industry have led to a resurgence of interest in optical glucose sensing and to realistic progress toward the development of an optical glucose sensor. Such a sensor has the potential to significantly improve the quality of life for the estimated 16 million diabetics in this country by making routine glucose measurements more convenient. Currently over 100 small companies and universities are working to develop noninvasive or minimally invasive glucose sensing technologies, and optical methods play a large role in these efforts. It has become overwhelmingly clear that frequent monitoring and tight control of bloodmore » sugar levels are requisite for effective management of Diabetes mellitus and reduction of the complications associated with this disease. The pain and trouble associated with current “finger-stick” methods for blood glucose monitoring result in decreased patient compliance and a failure to control blood sugar levels. Thus, the development of a convenient noninvasive blood glucose monitor holds the potential to significantly reduce the morbidity and mortality associated with Diabetes. A method and apparatus for noninvasive measurement of blood glucose concentration based on transilluminated laser beam via the Index Finger has been reported in this paper. This method depends on photodiode based laser operating at 632.8 nm wavelength. During measurement, the index finger is inserted into the glucose sensing unit, the transilluminated optical signal is converted into an electrical signal, compared with the reference electrical signal, and the obtained difference signal is processed by signal processing unit which presents the results in the form of blood glucose concentration. This method would enable the monitoring blood glucose level of the diabetic patient continuously, safely and noninvasively.« less

  17. OLAM: A wearable, non-contact sensor for continuous heart-rate and activity monitoring.

    PubMed

    Albright, Ryan K; Goska, Benjamin J; Hagen, Tory M; Chi, Mike Y; Cauwenberghs, G; Chiang, Patrick Y

    2011-01-01

    A wearable, multi-modal sensor is presented that can non-invasively monitor a patient's activity level and heart function concurrently for more than a week. The 4 in(2) sensor incorporates both a non-contact heartrate sensor and a 5-axis inertial measurement unit (IMU), allowing simultaneous heart, respiration, and movement monitoring without requiring physical contact with the skin [1]. Hence, this Oregon State University Life and Activity Monitor (OLAM) provides the unique opportunity to combine motion data with heart-rate information, enabling assessment of actual physical activity beyond conventional movement sensors. OLAM also provides a unique platform for non-contact sensing, enabling the filtering of movement artifacts generated by the non-contact capacitive interface, using the IMU data as a movement noise channel. Intended to be used in clinical trials for weeks at a time with no physician intervention, the OLAM allows continuous non-invasive monitoring of patients, providing the opportunity for long-term observation into a patient's physical activity and subtle longitudinal changes.

  18. Home noninvasive positive pressure ventilation with built-in software in stable hypercapnic COPD: a short-term prospective, multicenter, randomized, controlled trial.

    PubMed

    Zhou, Luqian; Li, Xiaoying; Guan, Lili; Chen, Jianhua; Guo, Bingpeng; Wu, Weiliang; Huo, Yating; Zhou, Ziqing; Liang, Zhenyu; Zhou, Yuqi; Tan, Jie; Chen, Xin; Song, Yuanlin; Chen, Rongchang

    2017-01-01

    The benefits of noninvasive positive pressure ventilation (NPPV) in patients with hypercapnic COPD are controversial. It is presumed that methodology and appropriate use of NIV ventilator might be crucial for the outcomes. With the new built-in software, the performance of NIV can be monitored at home, which can guarantee the compliance and appropriate use. This study investigated effects of home use of NIV in hypercapnia in COPD patients using the NIV ventilator with built-in software for monitoring. The current multicenter prospective, randomized, controlled trial enrolled patients with stable GOLD stages III and IV hypercapnic COPD. Patients were randomly assigned via a computer-generated randomization sequence, with a block size of four patients, to continue optimized treatment (control group) or to receive additional NPPV (intervention group) for 3 months. The primary outcome was arterial carbon dioxide pressure (PaCO 2 ). Data were derived from built-in software and analyzed every 4 weeks. Analysis was carried out with the intention to treat. This study is registered with ClinicalTrials.gov, number NCT02499718. Patients were recruited from 20 respiratory units in China from October 1, 2015, and recruitment was terminated with a record of the vital statistics on May 31, 2016. A total of 115 patients were randomly assigned to the NPPV group (n=57) or the control group (n=58). Patients complied well with NPPV therapy (mean [± standard deviation] day use 5.6±1.4 h). The mean estimation of leaks was 37.99±13.71 L/min. The changes in PaCO 2 (-10.41±0.97 vs -4.32±0.68 mmHg, P =0.03) and 6-min walk distance (6MWD) (38.2% vs 18.2%, P =0.02) were statistically significant in the NPPV group versus the control group. COPD assessment test (CAT) showed a positive trend ( P =0.06) in favor of the NPPV group. Pulmonary function and dyspnea were not different between groups. Ventilators equipped with built-in software provided methodology for monitoring NIV use at home, which could facilitate the improvement of compliance and quality control of NIV use. It was shown that three months use of NIV at home could reduce the PaCO 2 and improve exercise tolerance (6MWD) in chronic hypercapnic COPD patients.

  19. Follow-up of Contacts of Middle East Respiratory Syndrome Coronavirus-Infected Returning Travelers, the Netherlands, 2014.

    PubMed

    Mollers, Madelief; Jonges, Marcel; Pas, Suzan D; van der Eijk, Annemiek A; Dirksen, Kees; Jansen, Casper; Gelinck, Luc B S; Leyten, Eliane M S; Thurkow, Ingrid; Groeneveld, Paul H P; van Gageldonk-Lafeber, Arianne B; Koopmans, Marion P; Timen, Aura

    2015-09-01

    Notification of 2 imported cases of infection with Middle East respiratory syndrome coronavirus in the Netherlands triggered comprehensive monitoring of contacts. Observed low rates of virus transmission and the psychological effect of contact monitoring indicate that thoughtful assessment of close contacts is prudent and must be guided by clinical and epidemiologic risk factors.

  20. Non-invasive, photonics-based diagnostic, imaging, monitoring, and light delivery techniques for the recognition, quantification and treatment of malignant and chronic inflammatory conditions

    NASA Astrophysics Data System (ADS)

    Davies, N.; Davies-Shaw, D.; Shaw, J. D.

    2007-02-01

    We report firsthand on innovative developments in non-invasive, biophotonic techniques for a wide range of diagnostic, imaging and treatment options, including the recognition and quantification of cancerous, pre-cancerous cells and chronic inflammatory conditions. These techniques have benefited from the ability to target the affected site by both monochromatic light and broad multiple wavelength spectra. The employment of such wavelength or color-specific properties embraces the fluorescence stimulation of various photosensitizing drugs, and the instigation and detection of identified fluorescence signatures attendant upon laser induced fluorescence (LIF) phenomena as transmitted and propagated by precancerous, cancerous and normal tissue. In terms of tumor imaging and therapeutic and treatment options, we have exploited the abilities of various wavelengths to penetrate to different depths, through different types of tissues, and have explored quantifiable absorption and reflection characteristics upon which diagnostic assumptions can be reliably based and formulated. These biophotonic-based diagnostic, sensing and imaging techniques have also benefited from, and have been further enhanced by, the integrated ability to provide various power levels to be employed at various stages in the procedure. Applications are myriad, including non-invasive, non destructive diagnosis of in vivo cell characteristics and functions; light-based tissue analysis; real-time monitoring and mapping of brain function and of tumor growth; real time monitoring of the surgical completeness of tumor removal during laser-imaged/guided brain resection; diagnostic procedures based on fluorescence life-time monitoring, the monitoring of chronic inflammatory conditions (including rheumatoid arthritis), and continuous blood glucose monitoring in the control of diabetes.

  1. Noninvasive ventilation in the event of acute respiratory failure in patients with idiopathic pulmonary fibrosis.

    PubMed

    Vianello, Andrea; Arcaro, Giovanna; Battistella, Laura; Pipitone, Emanuela; Vio, Stefania; Concas, Alessandra; Paladini, Luciana; Gallan, Federico; Marchi, Maria Rita; Tona, Francesco; Iliceto, Sabino

    2014-08-01

    Some patients with idiopathic pulmonary fibrosis (IPF) develop severe acute respiratory failure (ARF) requiring admission to an intensive care unit (ICU) and ventilatory support. A limited number of observational studies have reported that noninvasive ventilation (NIV) can be an effective treatment to support breathing and to prevent use of invasive mechanical ventilation in these patients. This study aimed to retrospectively investigate the clinical status and outcomes in IPF patients receiving NIV for ARF and to identify those clinical and laboratory characteristics, which could be considered risk factors for its failure. This is a retrospective analysis of short-term outcomes in 18 IPF patients being administered NIV for ARF. This study was conducted in a 4-bed respiratory ICU (RICU) in a university hospital. Eighteen IPF patients who were administered NIV between January 1, 2005, and April 30, 2013, were included. The outcome measures are the need for endotracheal intubation despite NIV treatment and mortality rate during their RICU stay. The length of the patients' stay in the RICU and their survival rate following RICU admission were also evaluated. Noninvasive ventilation was successful in 8 patients and unsuccessful in 10 who required endotracheal intubation. All the patients in the NIV failure group died within 20.2±15.3 days of intubation. The patients in the NIV success group spent fewer days in the RICU (11.6±4.5 vs 24.6±13.7; P=.0146). The median survival time was significantly shorter for the patients in the NIV failure with respect to the success group (18.0 [95% confidence interval {CI}, 9.0-25.0] vs 90.0 [95% CI, 65.0-305.0] days; P<.0001); the survival rate at 90 days was, likewise, lower in the NIV failure group (0% vs 34%±19.5%). At admission, the patients in the failure group had significantly higher respiratory rate values (36.9±7.8 vs 30.5±3.3 breaths/min; P=.036), plasma N-terminal fragment of the prohormone of B-type natriuretic peptide (NT-proBNP) levels (4528.8±4012.8 vs 634.6±808.0 pg/mL; P=.023) and serum C-reactive protein values (72.0±50.0 vs 20.7±24.0 μg/mL; P=.0289) with respect to those in the success group. Noninvasive ventilation failure was correlated to the plasma NT-proBNP levels at RICU admission (P=.0326) with an odds ratio of 12.2 (95% CI, 1.2 to infinity) in the patients with abnormally high values (>900 pg/mL). The outcome of IPF patients who were administered NIV was quite poor. The use of NIV was, nevertheless, found to be associated with clinical benefits in selected IPF patients, preventing the need for intubation and reducing the rate of complications/death. Elevated plasma NT-proBNP levels at the time of ICU admission is a simple clinical marker for poor NIV outcome. Copyright © 2014 Elsevier Inc. All rights reserved.

  2. Monitoring internal organ motion with continuous wave radar in CT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pfanner, Florian; Maier, Joscha; Allmendinger, Thomas

    Purpose: To avoid motion artifacts in medical imaging or to minimize the exposure of healthy tissues in radiation therapy, medical devices are often synchronized with the patient's respiratory motion. Today's respiratory motion monitors require additional effort to prepare the patients, e.g., mounting a motion belt or placing an optical reflector on the patient's breast. Furthermore, they are not able to measure internal organ motion without implanting markers. An interesting alternative to assess the patient's organ motion is continuous wave radar. The aim of this work is to design, implement, and evaluate such a radar system focusing on application in CT.Methods:more » The authors designed a radar system operating in the 860 MHz band to monitor the patient motion. In the intended application of the radar system, the antennas are located close to the patient's body inside the table of a CT system. One receive and four transmitting antennas are used to avoid the requirement of exact patient positioning. The radar waves propagate into the patient's body and are reflected at tissue boundaries, for example at the borderline between muscle and adipose tissue, or at the boundaries of organs. At present, the authors focus on the detection of respiratory motion. The radar system consists of the hardware mentioned above as well as of dedicated signal processing software to extract the desired information from the radar signal. The system was evaluated using simulations and measurements. To simulate the radar system, a simulation model based on radar and wave field equations was designed and 4D respiratory-gated CT data sets were used as input. The simulated radar signals and the measured data were processed in the same way. The radar system hardware and the signal processing algorithms were tested with data from ten volunteers. As a reference, the respiratory motion signal was recorded using a breast belt simultaneously with the radar measurements.Results: Concerning the measurements of the test persons, there is a very good correlation (ρ= 0.917) between the respiratory motion phases received by the radar system and the external motion monitor. Our concept of using an array of transmitting antennas turned out to be widely insensitive to the positioning of the test persons. A time shift between the respiratory motion curves recorded with the radar system and the motion curves from the external respiratory monitor was observed which indicates a slight difference between internal organ motion and motion detected by the external respiratory monitor. The simulations were in good accordance with the measurements.Conclusions: A continuous wave radar operating in the near field of the antennas can be used to determine the respiratory motion of humans accurately. In contrast to trigger systems used today, the radar system is able to measure motion inside the body. If such a monitor was routinely available in clinical CT, it would be possible optimizing the scan start with respect to the respiratory state of the patient. Breathing commands would potentially widely be avoided, and as far as uncooperative patients or children are concerned, less sedation might be necessary. Further applications of the radar system could be in radiation therapy or interventional imaging for instance.« less

  3. Noninvasive wearable sensor for indirect glucometry.

    PubMed

    Zilberstein, Gleb; Zilberstein, Roman; Maor, Uriel; Righetti, Pier Giorgio

    2018-04-02

    A noninvasive mini-sensor for blood glucose concentration assessment has been developed. The monitoring is performed by gently pressing a wrist or fingertip onto the chemochromic mixture coating a thin glass or polymer film positioned on the back panel of a smart watch with PPG/HRM (photoplethysmographic/heart rate monitoring sensor). The various chemochromic components measure the absolute values of the following metabolites present in the sweat: acetone, acetone beta-hydroxybutirate, aceto acetate, water, carbon dioxide, lactate anion, pyruvic acid, Na and K salts. Taken together, all these parameters give information about blood glucose concentration, calculated via multivariate analysis based on neural network algorithms built into the sensor. The Clarke Error Grid shows an excellent correlation between data measured by the standard invasive glucose analyser and the present noninvasive sensor, with all points aligned along a 45-degree diagonal and contained almost exclusively in sector A. Graphs measuring glucose levels five times a day (prior, during and after breakfast and prior, during and after lunch), for different individuals (males and females) show a good correlation between the two curves of conventional, invasive meters vs. the noninvasive sensor, with an error of ±15%. This novel, noninvasive sensor for indirect glucometry is fully miniaturized, easy to use and operate and could represent a valid alternative in clinical settings and for individual, personal users, to current, invasive tools. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Noninvasive optoacoustic monitoring of cerebral venous blood oxygenation in newborns

    NASA Astrophysics Data System (ADS)

    Petrov, Irene Y.; Wynne, Karon E.; Petrov, Yuriy; Esenaliev, Rinat O.; Richardson, C. Joan; Prough, Donald S.

    2012-02-01

    Cerebral ischemia after birth and during labor is a major cause of death and severe complications such as cerebral palsy. In the USA alone, cerebral palsy results in permanent disability of 10,000 newborns per year and approximately 500,000 of the total population. Currently, no technology is capable of direct monitoring of cerebral oxygenation in newborns. This study proposes the use of an optoacoustic technique for noninvasive cerebral ischemia monitoring by probing the superior sagittal sinus (SSS), a large central cerebral vein. We developed and built a multi-wavelength, near-infrared optoacoustic system suitable for noninvasive monitoring of cerebral ischemia in newborns with normal weight (NBW), low birth-weight (LBW, 1500 - 2499 g) and very low birth-weight (VLBW, < 1500 g). The system was capable of detecting SSS signals through the open anterior and posterior fontanelles as well as through the skull. We tested the system in NBW, LBW, and VLBW newborns (weight range: from 675 g to 3,000 g) admitted to the neonatal intensive care unit. We performed single and continuous measurements of the SSS blood oxygenation. The data acquisition, processing and analysis software developed by our group provided real-time, absolute SSS blood oxygenation measurements. The SSS blood oxygenation ranged from 60% to 80%. Optoacoustic monitoring of the SSS blood oxygenation provides valuable information because adequate cerebral oxygenation would suggest that no therapy was necessary; conversely, evidence of cerebral ischemia would prompt therapy to increase cerebral blood flow.

  5. A Universal Noninvasive Continuous Blood Pressure Measurement System for Remote Healthcare Monitoring.

    PubMed

    Mukherjee, Ramtanu; Ghosh, Sanchita; Gupta, Bharat; Chakravarty, Tapas

    2018-01-22

    The effectiveness of any remote healthcare monitoring system depends on how much accurate, patient-friendly, versatile, and cost-effective measurement it is delivering. There has always been a huge demand for such a long-term noninvasive remote blood pressure (BP) measurement system, which could be used worldwide in the remote healthcare industry. Thus, noninvasive continuous BP measurement and remote monitoring have become an emerging area in the remote healthcare industry. Photoplethysmography-based (PPG) BP measurement is a continuous, unobtrusive, patient-friendly, and cost-effective solution. However, BP measurements through PPG sensors are not much reliable and accurate due to some major limitations like pressure disturbance, motion artifacts, and variations in human skin tone. A novel reflective PPG sensor has been developed to eliminate the abovementioned pressure disturbance and motion artifacts during the BP measurement. Considering the variations of the human skin tone across demography, a novel algorithm has been developed to make the BP measurement accurate and reliable. The training dataset captured 186 subjects' data and the trial dataset captured another new 102 subjects' data. The overall accuracy achieved by using the proposed method is nearly 98%. Thus, demonstrating the efficacy of the proposed method. The developed BP monitoring system is quite accurate, reliable, cost-effective, handy, and user friendly. It is also expected that this system would be quite useful to monitor the BP of infants, elderly people, patients having wounds, burn injury, or in the intensive care unit environment.

  6. Monitoring Hospitalized Adult Patients for Opioid-Induced Sedation and Respiratory Depression.

    PubMed

    Jungquist, Carla R; Smith, Kirsten; Nicely, Kelly L Wiltse; Polomano, Rosemary C

    2017-03-01

    : Opioid analgesics are commonly administered to hospitalized patients to treat acute pain, but these drugs put patients at risk for serious adverse events, such as unintended advancing sedation, respiratory depression, and death. Nurses play an important role in keeping patients safe by making clinical decisions about the frequency and intensity with which patients receiving IV and epidural opioids should be monitored. To make sound clinical judgments, nurses must be aware of the factors that place patients at elevated risk for adverse opioid-related effects and know how to screen and assess patients for these risks. The authors review the literature on unintended advancing sedation and respiratory depression associated with opioid administration and present evidence-based recommendations for clinical decision making and patient monitoring, using both nursing assessments and electronic technologies.

  7. Noninvasive Ventilation of Patients with Acute Respiratory Distress Syndrome. Insights from the LUNG SAFE Study.

    PubMed

    Bellani, Giacomo; Laffey, John G; Pham, Tài; Madotto, Fabiana; Fan, Eddy; Brochard, Laurent; Esteban, Andres; Gattinoni, Luciano; Bumbasirevic, Vesna; Piquilloud, Lise; van Haren, Frank; Larsson, Anders; McAuley, Daniel F; Bauer, Philippe R; Arabi, Yaseen M; Ranieri, Marco; Antonelli, Massimo; Rubenfeld, Gordon D; Thompson, B Taylor; Wrigge, Hermann; Slutsky, Arthur S; Pesenti, Antonio

    2017-01-01

    Noninvasive ventilation (NIV) is increasingly used in patients with acute respiratory distress syndrome (ARDS). The evidence supporting NIV use in patients with ARDS remains relatively sparse. To determine whether, during NIV, the categorization of ARDS severity based on the Pa O 2 /Fi O 2 Berlin criteria is useful. The LUNG SAFE (Large Observational Study to Understand the Global Impact of Severe Acute Respiratory Failure) study described the management of patients with ARDS. This substudy examines the current practice of NIV use in ARDS, the utility of the Pa O 2 /Fi O 2 ratio in classifying patients receiving NIV, and the impact of NIV on outcome. Of 2,813 patients with ARDS, 436 (15.5%) were managed with NIV on Days 1 and 2 following fulfillment of diagnostic criteria. Classification of ARDS severity based on Pa O 2 /Fi O 2 ratio was associated with an increase in intensity of ventilatory support, NIV failure, and intensive care unit (ICU) mortality. NIV failure occurred in 22.2% of mild, 42.3% of moderate, and 47.1% of patients with severe ARDS. Hospital mortality in patients with NIV success and failure was 16.1% and 45.4%, respectively. NIV use was independently associated with increased ICU (hazard ratio, 1.446 [95% confidence interval, 1.159-1.805]), but not hospital, mortality. In a propensity matched analysis, ICU mortality was higher in NIV than invasively ventilated patients with a Pa O 2 /Fi O 2 lower than 150 mm Hg. NIV was used in 15% of patients with ARDS, irrespective of severity category. NIV seems to be associated with higher ICU mortality in patients with a Pa O 2 /Fi O 2 lower than 150 mm Hg. Clinical trial registered with www.clinicaltrials.gov (NCT 02010073).

  8. High mortality in patients with influenza A pH1N1 2009 admitted to a pediatric intensive care unit: a predictive model of mortality.

    PubMed

    Torres, Silvio Fabio; Iolster, Thomas; Schnitzler, Eduardo Julio; Farias, Julio Alberto; Bordogna, Adriana Claudia; Rufach, Daniel; Montes, María José; Siaba, Alejandro Javier; Rodríguez, María Gabriela; Jabornisky, Roberto; Colman, Carmen; Fernández, Analia; Caprotta, Gustavo; Diaz, Silvia; Poterala, Roxana; De Meyer, Marcela; Penazzi, Matías Enrique; González, Gustavo; Saenz, Silvia; Recupero, Oscar; Zapico, Luis; Alarcon, Blanca; Ariel, Esen; Minces, Pablo; Mari, Eduardo; Carnie, Antonio; Garea, Mónica; Jaen, Roxana

    2012-03-01

    To describe the clinical characteristics and outcome of patients admitted to pediatric intensive care with influenza A (pH1N1) 2009 in Argentina. Retrospective observational study. Thirteen pediatric intensive care units in Argentina. One hundred and forty-two patients with confirmed or suspected influenza A (H1N1). None. We included 142 critically ill patients. The median age was 19 months (range, 2-110 months) with 39% of the patients <24 months of age. Ninety-nine patients (70%) had an underlying disease. Influenza A (pH1N1) 2009 infection was confirmed in 90 patients and the remaining 52 had a positive direct immunofluorescence assay for influenza A. The median length of stay in the pediatric intensive care unit was 12 days (range, 2-52 days). One hundred eighteen patients (83%) received invasive mechanical ventilation and 19 patients were treated with noninvasive ventilation; however, seven of the patients receiving noninvasive ventilation later needed mechanical ventilation. Sixty-eight patients died (47%) with the most frequent cause refractory hypoxemia. Multivariate logistic regression analysis showed that age <24 months (odds ratio, 2.87; 2.35-3.93), asthma (odds ratio, 1.34; 1.20-2.91), and respiratory coinfection with respiratory syncytial virus (odds ratio, 2.92; 1.20-4.10) were associated with higher mortality. As expected, mechanical ventilation and treatment with inotropes were also associated with increased mortality. The mortality of children admitted to the pediatric intensive care unit with 2009 pH1N1 influenza was high (47%) in our population. Age <24 months, asthma, respiratory coinfection, need of mechanical ventilation, and treatment with inotropes were predictors of poorer outcome.

  9. [Non-invasive ventilation in 'do-not-intubate' patients in a chronic disease hospital. One year follow-up study].

    PubMed

    Tabernero Huguet, Eva; Gil Alaña, Pilar; Arana-Arri, Eunate; Citores Martín, Leyre; Alkiza Basañez, Ramon; Hernandez Gil, Anibal; Gil Molet, Alejandra

    2016-01-01

    Elderly patients with multiple morbidity and do not intubate (DNI) orders frequently present with acute respiratory failure. There are data supporting the effectiveness of non-invasive ventilation (NIV) in this context. Our chronic disease hospital developed an integrated care clinical pathway for the use of NIV in acute respiratory failure in the emergency room and wards in 2010. The aim of this study was to assess the outcome of NIV in patients with acute respiratory failure who had a DNI order in a sub-acute care hospital. Observational, one year-follow up study. The main variables were in-hospital mortality and one year mortality. Other variables recorded were: demographics, clinical data, functional data, performance of daily life activities, dementia, arterial blood gases and re-admissions. The study included a total of 102 patients, of which 22% were in institutions. The mean age 81±7.47% males, with a Charlson index 3.7±1, and Barthel index 54±31. The overall mortality during the admission was 33% (34 patients). Among those patients ventilated outside the protocol indication, the mortality was significantly greater, at 71% (P>.05). Overall one-year survival rate was 46%. This survival rate was statistically higher in patients with obesity hypoventilation syndrome and a Barthel >50. NIV is a useful technique in a hospital for chronic patients in an elderly population with a therapeutic ceiling. Despite their disease severity and comorbidity, acceptable survival rates are achieved. A correct case selection is needed. Obesity hypoventilation syndrome and those with Barthel index >50 have a better prognosis. Copyright © 2015 SEGG. Publicado por Elsevier España, S.L.U. All rights reserved.

  10. Impact of noninvasive ventilation (NIV) trial for various types of acute respiratory failure in the emergency department; decreased mortality and use of the ICU.

    PubMed

    Tomii, Keisuke; Seo, Ryutaro; Tachikawa, Ryo; Harada, Yuka; Murase, Kimihiko; Kaji, Reiko; Takeshima, Yoshimi; Hayashi, Michio; Nishimura, Takashi; Ishihara, Kyosuke

    2009-01-01

    Trial of noninvasive ventilation (NIV) in the emergency department (ED) for heterogeneous acute respiratory failure (ARF) has been optional and its clinical benefit unclear. We conducted a retrospective cohort study comparing between two periods, October 2001-September 2003 and October 2004-September 2006, i.e., before and after adopting an NIV-trial strategy in which NIV was applied in the ED to any noncontraindicated ARF patients needing ventilatory support and was then continued in the intermediate-care-unit. During these two periods, we retrieved cases of ARF treated either invasively or with NIV, and compared the patients' in-hospital mortalities and the length of ICU and intermediate-care-unit stay. Compared were 73 (invasive 56, NIV 17) and 125 cases (invasive 31, NIV 94) retrieved from 271 and 415 emergent admissions with proper pulmonary etiologies for mechanical ventilation, respectively. Of their respiratory failures, type (hypercapnic/non-hypercapnic, 0.97 vs. 0.98) and severity (pH 7.23 vs. 7.21 for hypercapnic; PaO(2)/FiO(2) 133 vs. 137 for non-hypercapnic) were similar, and the rate of predisposing etiologies was not significantly different. However, excluding those with recurrent aspiration pneumonia for whom NIV was mostly used as "ceiling" treatment, significant reductions in both overall in-hospital mortality (38%-19%, risk ratio 0.51, 95% CI 0.31-0.84), and median length of ICU and intermediate-care-unit stay (12 vs. 5 days, P<0.0001) were found. NIV-trial in the ED for all possible patients with ARF of pulmonary etiologies, excluding those with recurrent aspiration pneumonia, may reduce overall in-hospital mortality and ICU stays.

  11. Acute respiratory failure in patients with hematological malignancies: outcomes according to initial ventilation strategy. A groupe de recherche respiratoire en réanimation onco-hématologique (Grrr-OH) study.

    PubMed

    Lemiale, Virginie; Resche-Rigon, Matthieu; Mokart, Djamel; Pène, Frederic; Rabbat, Antoine; Kouatchet, Achille; Vincent, François; Bruneel, Fabrice; Nyunga, Martine; Lebert, Christine; Perez, Pierre; Meert, Anne-Pascale; Benoit, Dominique; Chevret, Sylvie; Azoulay, Elie

    2015-12-01

    In patients with hematological malignancies and acute respiratory failure (ARF), noninvasive ventilation was associated with a decreased mortality in older studies. However, mortality of intubated patients decreased in the last years. In this study, we assess outcomes in those patients according to the initial ventilation strategy. We performed a post hoc analysis of a prospective multicentre study of critically ill hematology patients, in 17 intensive care units in France and Belgium. Patients with hematological malignancies admitted for ARF in 2010 and 2011 and who were not intubated at admission were included in the study. A propensity score-based approach was used to assess the impact of NIV compared to oxygen only on hospital mortality. Among 1011 patients admitted to ICU during the study period, 380 met inclusion criteria. Underlying diseases included lymphoid (n = 162, 42.6 %) or myeloid (n = 141, 37.1 %) diseases. ARF etiologies were pulmonary infections (n = 161, 43 %), malignant infiltration (n = 65, 17 %) or cardiac pulmonary edema (n = 40, 10 %). Mechanical ventilation was ultimately needed in 94 (24.7 %) patients, within 3 [2-5] days of ICU admission. Hospital mortality was 32 % (123 deaths). At ICU admission, 142 patients received first-line noninvasive ventilation (NIV), whereas 238 received oxygen only. Fifty-five patients in each group (NIV or oxygen only) were matched according the propensity score. NIV was not associated with decreased hospital mortality [OR 1.5 (0.62-3.65)]. In hematology patients with acute respiratory failure, initial treatment with NIV did not improve survival compared to oxygen only. gov number NCT 01172132.

  12. Comparison of two humidification systems for long-term noninvasive mechanical ventilation.

    PubMed

    Nava, S; Cirio, S; Fanfulla, F; Carlucci, A; Navarra, A; Negri, A; Ceriana, P

    2008-08-01

    There is no consensus concerning the best system of humidification during long-term noninvasive mechanical ventilation (NIMV). In a technical pilot randomised crossover 12-month study, 16 patients with stable chronic hypercapnic respiratory failure received either heated humidification or heat and moisture exchanger. Compliance with long-term NIMV, airway symptoms, side-effects and number of severe acute pulmonary exacerbations requiring hospitalisation were recorded. Two patients died. Intention-to-treat statistical analysis was performed on 14 patients. No significant differences were observed in compliance with long-term NIMV, but 10 out of 14 patients decided to continue long-term NIMV with heated humidification at the end of the trial. The incidence of side-effects, except for dry throat (significantly more often present using heat and moisture exchanger), hospitalisations and pneumonia were not significantly different. In the present pilot study, the use heated humidification and heat and moisture exchanger showed similar tolerance and side-effects, but a higher number of patients decided to continue long-term noninvasive mechanical ventilation with heated humidification. Further larger studies are required in order to confirm these findings.

  13. Clinical use of exhaled volatile organic compounds in pulmonary diseases: a systematic review

    PubMed Central

    2012-01-01

    There is an increasing interest in the potential of exhaled biomarkers, such as volatile organic compounds (VOCs), to improve accurate diagnoses and management decisions in pulmonary diseases. The objective of this manuscript is to systematically review the current knowledge on exhaled VOCs with respect to their potential clinical use in asthma, lung cancer, chronic obstructive pulmonary disease (COPD), cystic fibrosis (CF), and respiratory tract infections. A systematic literature search was performed in PubMed, EMBASE, Cochrane database, and reference lists of retrieved studies. Controlled, clinical, English-language studies exploring the diagnostic and monitoring value of VOCs in asthma, COPD, CF, lung cancer and respiratory tract infections were included. Data on study design, setting, participant characteristics, VOCs techniques, and outcome measures were extracted. Seventy-three studies were included, counting in total 3,952 patients and 2,973 healthy controls. The collection and analysis of exhaled VOCs is non-invasive and could be easily applied in the broad range of patients, including subjects with severe disease and children. Various research groups demonstrated that VOCs profiles could accurately distinguish patients with a pulmonary disease from healthy controls. Pulmonary diseases seem to be characterized by a disease specific breath-print, as distinct profiles were found in patients with dissimilar diseases. The heterogeneity of studies challenged the inter-laboratory comparability. In conclusion, profiles of VOCs are potentially able to accurately diagnose various pulmonary diseases. Despite these promising findings, multiple challenges such as further standardization and validation of the diverse techniques need to be mastered before VOCs can be applied into clinical practice. PMID:23259710

  14. Heart rate variability to monitor performance in elite athletes: Criticalities and avoidable pitfalls.

    PubMed

    Lucini, Daniela; Marchetti, Ilaria; Spataro, Antonio; Malacarne, Mara; Benzi, Manuela; Tamorri, Stefano; Sala, Roberto; Pagani, Massimo

    2017-08-01

    Spectral analysis of Heart Rate Variability (HRV) is a simple, non-invasive technique that is widely used in sport to assess sympatho-vagal regulation of the heart. Its employment is increasing partly due to the rising usage of wearable devices. However data acquisition using these devices may be suboptimal because they cannot discriminate between sinus and non-sinus beats and do not record any data regarding respiratory frequency. This information is mandatory for a correct clinical interpretation. This study involved 974 elite athletes, all of them underwent a complete autonomic assessment, by way of Autoregressive HRV analysis. In 91 subjects (9% of the total population) we observed criticalities of either cardiac rhythm or respiration. Through perusal of one-lead ECG analysis we observed that 77 subjects had atrial or ventricular ectopy, i.e. conditions which impair stationarity and sinus rhythm. Running anyway autonomic nervous system analysis in this population, we observed that RR variance and raw values of LF and HF regions are significantly higher in arrhythmic subjects. In addition 14 subjects had slow (about 6 breath/min, 0.1Hz) respiration. This condition clouds the separation between LF from HF spectral regions of RR interval variability, respectively markers of the prevalent sympathetic and vagal modulation of SA node and of their synergistic interaction. Caution must be payed when assessing HRV with non-ECG wearable devices. Recording ECG signal and ensuring that respiratory rate is higher than 10 breath/min are both prerequisites for a more reliable analysis of HRV particularly in athletes. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Cerebral energy metabolism in diving and non-diving birds during hypoxia and apnoeic asphyxia.

    PubMed Central

    Bryan, R M; Jones, D R

    1980-01-01

    1. Cerebral energy metabolism during apnoeic asphyxia and steady-state hypoxia was compared in ducks and chickens; ducks tolerate apnoeic asphyxia 3-8 times longer than chickens. 2. Fluctuations in the reduced form of respiratory chain nicotinamide adenine dinucleotide (NADH) were monitored from the left cerebral hemisphere by a noninvasive fluorometric technique and used as an indicator of mitochondrial hypoxia. NADH fluorescence was expressed in aribtrary units (a.u.) where 100 a.u. was defined as the fluorescence change from normoxia to anoxia. Electroencephalogram (e.e.g.) and surface Po2 were recorded from the right hemisphere. 3. After 1 min of asphyxia NADH fluorescence increased by 37 a.u.+/-3.60 S.E. of mean (n=54) in paralysed chickens and 8 a.u.+/-1.41 (n=55) in aralysed ducks. After 2 min the fluorescence increased by only 15 a.u.+/-1.95 in ducks. 4. Both species showed an isoelectric e.e.g. when fluorescence increased by approximately 35 a.u., indicating that anaerobic ATP production in ducks did not maintain brain function (e.e.g.) for a greater accumulation of respiratory chain NADH. 5. At a given decrease in tissue Po2 ducks and chickens showed the same level of NADH increase, indicating that both species are equally dependent on tissue Po2 for the maintenance of redox state. 6. We conclude that biochemical adjustment which enhance anaerobic ATP production and/or prolong oxidative phosphorylation during progressive hypoxia are not responsible for increased cerebral tolerance to apnoeic asphyxia in the duck. PMID:7381772

  16. Setting ventilation parameters guided by electrical impedance tomography in an animal trial of acute respiratory distress syndrome

    NASA Astrophysics Data System (ADS)

    Czaplik, Michael; Biener, Ingeborg; Leonhardt, Steffen; Rossaint, Rolf

    2014-03-01

    Since mechanical ventilation can cause harm to lung tissue it should be as protective as possible. Whereas numerous options exist to set ventilator parameters, an adequate monitoring is lacking up to date. The Electrical Impedance Tomography (EIT) provides a non-invasive visualization of ventilation which is relatively easy to apply and commercially available. Although there are a number of published measures and parameters derived from EIT, it is not clear how to use EIT to improve clinical outcome of e.g. patients suffering from acute respiratory distress syndrome (ARDS), a severe disease with a high mortality rate. On the one hand, parameters should be easy to obtain, on the other hand clinical algorithms should consider them to optimize ventilator settings. The so called Global inhomogeneity (GI) index bases on the fact that ARDS is characterized by an inhomogeneous injury pattern. By applying positive endexpiratory pressures (PEEP), homogeneity should be attained. In this study, ARDS was induced by a double hit procedure in six pigs. They were randomly assigned to either the EIT or the control group. Whereas in the control group the ARDS network table was used to set the PEEP according to the current inspiratory oxygen fraction, in the EIT group the GI index was calculated during a decremental PEEP trial. PEEP was kept when GI index was lowest. Interestingly, PEEP was significantly higher in the EIT group. Additionally, two of these animals died ahead of the schedule. Obviously, not only homogeneity of ventilation distribution matters but also limitation of over-distension.

  17. Potential for noninvasive assessment of lung inhomogeneity using highly precise, highly time-resolved measurements of gas exchange

    PubMed Central

    Mountain, James E.; Santer, Peter; O’Neill, David P.; Smith, Nicholas M. J.; Ciaffoni, Luca; Couper, John H.; Ritchie, Grant A. D.; Hancock, Gus; Whiteley, Jonathan P.

    2018-01-01

    Inhomogeneity in the lung impairs gas exchange and can be an early marker of lung disease. We hypothesized that highly precise measurements of gas exchange contain sufficient information to quantify many aspects of the inhomogeneity noninvasively. Our aim was to explore whether one parameterization of lung inhomogeneity could both fit such data and provide reliable parameter estimates. A mathematical model of gas exchange in an inhomogeneous lung was developed, containing inhomogeneity parameters for compliance, vascular conductance, and dead space, all relative to lung volume. Inputs were respiratory flow, cardiac output, and the inspiratory and pulmonary arterial gas compositions. Outputs were expiratory and pulmonary venous gas compositions. All values were specified every 10 ms. Some parameters were set to physiologically plausible values. To estimate the remaining unknown parameters and inputs, the model was embedded within a nonlinear estimation routine to minimize the deviations between model and data for CO2, O2, and N2 flows during expiration. Three groups, each of six individuals, were studied: young (20–30 yr); old (70–80 yr); and patients with mild to moderate chronic obstructive pulmonary disease (COPD). Each participant undertook a 15-min measurement protocol six times. For all parameters reflecting inhomogeneity, highly significant differences were found between the three participant groups (P < 0.001, ANOVA). Intraclass correlation coefficients were 0.96, 0.99, and 0.94 for the parameters reflecting inhomogeneity in deadspace, compliance, and vascular conductance, respectively. We conclude that, for the particular participants selected, highly repeatable estimates for parameters reflecting inhomogeneity could be obtained from noninvasive measurements of respiratory gas exchange. NEW & NOTEWORTHY This study describes a new method, based on highly precise measures of gas exchange, that quantifies three distributions that are intrinsic to the lung. These distributions represent three fundamentally different types of inhomogeneity that together give rise to ventilation-perfusion mismatch and result in impaired gas exchange. The measurement technique has potentially broad clinical applicability because it is simple for both patient and operator, it does not involve ionizing radiation, and it is completely noninvasive. PMID:29074714

  18. Towards a smart non-invasive fluid loss measurement system.

    PubMed

    Suryadevara, N K; Mukhopadhyay, S C; Barrack, L

    2015-04-01

    In this article, a smart wireless sensing non-invasive system for estimating the amount of fluid loss, a person experiences while physical activity is presented. The system measures three external body parameters, Heart Rate, Galvanic Skin Response (GSR, or skin conductance), and Skin Temperature. These three parameters are entered into an empirically derived formula along with the user's body mass index, and estimation for the amount of fluid lost is determined. The core benefit of the developed system is the affluence usage in combining with smart home monitoring systems to care elderly people in ambient assisted living environments as well in automobiles to monitor the body parameters of a motorist.

  19. Effects of optical clearing agents on noninvasive blood glucose monitoring with optical coherence tomography: a pilot study

    NASA Astrophysics Data System (ADS)

    He, Ruoyu; Wei, Huajiang; Gu, Huimin; Zhu, Zhengguo; Zhang, Yuqing; Guo, Xiao; Cai, Tiantian

    2012-10-01

    Recently, the capability of optical coherence tomography (OCT) has been demonstrated for noninvasive blood glucose monitoring. In this work, we investigate the administration of chemical agents onto human skin tissue to increase the transparency of the surface of the skin, as a means of improving the capability of OCT imaging for clinically relevant applications. Eight groups of experiments were proposed, in which different optical clearing agents (OCA) were used. The results indicate that, when properly used, some OCAs perform well in promoting the capability of OCT for noninvasive blood glucose monitoring. Among the four kinds of OCA we used, 50% v/v glycerol solute turns out to be the best enhancer. Compared with the results of the experiments in which no OCA was used, when 50% glycerol was applied onto the human skin topically, the correlation coefficient between the OCT signal slope (OCTSS) and blood glucose concentration (BGC) was improved by 7.1% on average, and the lag time between changes in the OCTSS and BGC was cut by 8 min on average. The results of 10 w/v mannitol were also good, but not as pronounced.

  20. Clinical results from a noninvasive blood glucose monitor

    NASA Astrophysics Data System (ADS)

    Blank, Thomas B.; Ruchti, Timothy L.; Lorenz, Alex D.; Monfre, Stephen L.; Makarewicz, M. R.; Mattu, Mutua; Hazen, Kevin

    2002-05-01

    Non-invasive blood glucose monitoring has long been proposed as a means for advancing the management of diabetes through increased measurement and control. The use of a near-infrared, NIR, spectroscopy based methodology for noninvasive monitoring has been pursued by a number of groups. The accuracy of the NIR measurement technology is limited by challenges related to the instrumentation, the heterogeneity and time-variant nature of skin tissue, and the complexity of the calibration methodology. In this work, we discuss results from a clinical study that targeted the evaluation of individual calibrations for each subject based on a series of controlled calibration visits. While the customization of the calibrations to individuals was intended to reduce model complexity, the extensive requirements for each individual set of calibration data were difficult to achieve and required several days of measurement. Through the careful selection of a small subset of data from all samples collected on the 138 study participants in a previous study, we have developed a methodology for applying a single standard calibration to multiple persons. The standard calibrations have been applied to a plurality of individuals and shown to be persistent over periods greater than 24 weeks.

Top