Intraocular lens based on double-liquid variable-focus lens.
Peng, Runling; Li, Yifan; Hu, Shuilan; Wei, Maowei; Chen, Jiabi
2014-01-10
In this work, the crystalline lens in the Gullstrand-Le Grand human eye model is replaced by a double-liquid variable-focus lens, the structure data of which are based on theoretical analysis and experimental results. When the pseudoaphakic eye is built in Zemax, aspherical surfaces are introduced to the double-liquid variable-focus lens to reduce the axial spherical aberration existent in the system. After optimization, the zoom range of the pseudoaphakic eye greatly exceeds that of normal human eyes, and the spot size on an image plane basically reaches the normal human eye's limit of resolution.
Vaez‐zadeh, Mehdi; Masoudi, S. Farhad; Rahmani, Faezeh; Knaup, Courtney; Meigooni, Ali S.
2015-01-01
The effects of gold nanoparticles (GNPs) in 125I brachytherapy dose enhancement on choroidal melanoma are examined using the Monte Carlo simulation technique. Usually, Monte Carlo ophthalmic brachytherapy dosimetry is performed in a water phantom. However, here, the compositions of human eye have been considered instead of water. Both human eye and water phantoms have been simulated with MCNP5 code. These simulations were performed for a fully loaded 16 mm COMS eye plaque containing 13 125I seeds. The dose delivered to the tumor and normal tissues have been calculated in both phantoms with and without GNPs. Normally, the radiation therapy of cancer patients is designed to deliver a required dose to the tumor while sparing the surrounding normal tissues. However, as the normal and cancerous cells absorbed dose in an almost identical fashion, the normal tissue absorbed radiation dose during the treatment time. The use of GNPs in combination with radiotherapy in the treatment of tumor decreases the absorbed dose by normal tissues. The results indicate that the dose to the tumor in an eyeball implanted with COMS plaque increases with increasing GNPs concentration inside the target. Therefore, the required irradiation time for the tumors in the eye is decreased by adding the GNPs prior to treatment. As a result, the dose to normal tissues decreases when the irradiation time is reduced. Furthermore, a comparison between the simulated data in an eye phantom made of water and eye phantom made of human eye composition, in the presence of GNPs, shows the significance of utilizing the composition of eye in ophthalmic brachytherapy dosimetry Also, defining the eye composition instead of water leads to more accurate calculations of GNPs radiation effects in ophthalmic brachytherapy dosimetry. PACS number: 87.53.Jw, 87.85.Rs, 87.10.Rt PMID:26699318
P gene as an inherited biomarker of human eye color.
Rebbeck, Timothy R; Kanetsky, Peter A; Walker, Amy H; Holmes, Robin; Halpern, Allan C; Schuchter, Lynn M; Elder, David E; Guerry, DuPont
2002-08-01
Human pigmentation, including eye color, has been associated with skin cancer risk. The P gene is the human homologue to the mouse pink-eye dilution locus and is responsible for oculocutaneous albinism type 2 and other phenotypes that confer eye hypopigmentation. The P gene is located on chromosome 15q11.2-q12, which is also the location of a putative eye pigmentation gene (EYCL3) inferred to exist by linkage analysis. Therefore, the P gene is a strong candidate for determination of human eye color. Using a sample of 629 normally pigmented individuals, we found that individuals were less likely to have blue or gray eyes if they had P gene variants Arg305Trp (P = 0.002), Arg419Gln (P = 0.001), or the combination of both variants (P = 0.003). These results suggest that P gene, in part, determines normal phenotypic variation in human eye color and may therefore represent an inherited biomarker of cutaneous cancer risk.
Theoretical investigation of aberrations upon ametropic human eyes
NASA Astrophysics Data System (ADS)
Tan, Bo; Chen, Ying-Ling; Lewis, J. W. L.; Baker, Kevin
2003-11-01
The human eye aberrations are important for visual acuity and ophthalmic diagnostics and surgical procedures. Reported monochromatic aberration data of the normal 20/20 human eyes are scarce. There exist even fewer reports of the relation between ametropic conditions and aberrations. We theoretically investigate the monochromatic and chromatic aberrations of human eyes for refractive errors of -10 to +10 diopters. Schematic human eye models are employed using optical design software for axial, index, and refractive types of ametropia.
Optical aberrations, retinal image quality and eye growth: Experimentation and modeling
NASA Astrophysics Data System (ADS)
Tian, Yibin
2007-12-01
Retinal image quality is important for normal eye growth. Optical aberrations are of interest for two reasons: first, they degrade retinal images; second, they might provide some cues to defocus. Higher than normal ocular aberrations have been previously associated with human myopia. However, these studies were cross-sectional in design, and only reported aberrations in terms of root mean square (RMS) errors of Zernike coefficients, a poor metric of optical quality. This dissertation presents results from investigations of ocular optical aberrations, retinal image quality and eye growth in chicks and humans. A number of techniques were utilized, including Shack-Hartmann aberrometry, high-frequency A-scan ultrasonography, ciliary nerve section (CNX), photorefractive keratectomy (PRK) as well as computer simulations and modeling. A technique to extract light scatter information from Shack-Hartmann images was also developed. The main findings of the dissertation are summarized below. In young chicks, most ocular aberrations decreased with growth in both normal and CNX eyes, and there were diurnal fluctuations in some aberrations. Modeling suggested active reduction in higher order aberrations (HOAs) during early development. Although CNX eyes manifested greater than normal HOAs, they showed near normal growth. Retinal image degradation varied greatly among individual eyes post-PRK in young chicks. Including light scatter information into analyses of retinal image quality better estimated the latter. Albino eyes showed more severe retinal image degradation than normal eyes, due to increased optical aberrations and light scatter, but their growth was similar to those of normal eyes, implying that they are relatively insensitive to retina image quality. Although the above results questioned the influence of optical aberrations on early ocular growth, some optical quality metrics, derived from optical aberrations data, could predict how much the eyes of young chicks subsequently elongated. The performance of some focus measures was very poor when non-defocus aberrations exceeded a certain level; presumably, these non-defocus aberrations might interfere with the eye's ability to interpret defocus. In anisomyopic human adults, more myopic eyes had larger anterior and vitreous chambers, greater astigmatism, and more positive spherical aberration. However, compared to isometropes, only interocular differences in spherical equivalent refractive errors were significantly increased.
Coudrillier, Baptiste; Tian, Jing; Alexander, Stephen; Myers, Kristin M.; Quigley, Harry A.; Nguyen, Thao D.
2012-01-01
Purpose. The objective of this study was to measure the biomechanical response of the human posterior sclera in vitro and to estimate the effects of age and glaucoma. Methods. Scleral specimens from 22 donors with no history of glaucoma and 11 donors with a history of glaucoma were excised 3 mm posterior to the equator and affixed to an inflation chamber. Optic nerve cross-sections were graded to determine the presence of axon loss. The time-dependent inflation response was measured in a series of pressure-controlled load–unload tests to 30 mm Hg and creep tests to 15 and 30 mm Hg. Circumferential and meridional strains were computed from the digital image correlation displacements, and midposterior stresses were determined from pressure and deformed geometry. Results. Among normal specimens, older age was predictive of a stiffer response and a thinner sclera. In the age group 75 to 93, diagnosed glaucoma eyes with axon damage were thicker than normal eyes. Both damaged and undamaged glaucoma eyes had a different strain response in the peripapillary sclera characterized by a stiffer meridional response. Undamaged glaucoma eyes had slower circumferential creep rates in the peripapillary sclera than normal eyes. Glaucoma eyes were not different from normal eyes in stresses and strains in the midposterior sclera. Conclusions. The observed differences in the biomechanical response of normal and glaucoma sclera may represent baseline properties that contribute to axon damage, or may be characteristics that result from glaucomatous disease. PMID:22395883
Nakajima, Masashi; Hiraoka, Takahiro; Hirohara, Yoko; Oshika, Tetsuro; Mihashi, Toshifumi
2015-01-01
Several researchers studied the longitudinal chromatic aberration (LCA) of the human eye and observed that it does not change due to age. We measured the LCA of 45 subjects’ normal right eyes at three distinct wavelengths (561, 690, and 840 nm) using a Hartmann–Shack wavefront aberrometer (HSWA) while consecutively switching between three light sources for wavefront sensing. We confirmed that the LCA of the human eye does not change due to age between 22 and 57 years. PMID:26203391
Double-pass measurement of human eye aberrations: limitations and practical realization
NASA Astrophysics Data System (ADS)
Letfullin, Renat R.; Belyakov, Alexey I.; Cherezova, Tatyana Y.; Kudryashov, Alexis V.
2004-11-01
The problem of correct eye aberrations measurement is very important with the rising widespread of a surgical procedure for reducing refractive error in the eye, so called, LASIK (laser-assisted in situ keratomileusis). The double-pass technique commonly used for measuring aberrations of a human eye involves some uncertainties. One of them is loosing the information about odd human eye aberrations. We report about investigations of the applicability limit of the double-pass measurements depending upon the aberrations status introduced by human eye and actual size of the entrance pupil. We evaluate the double-pass effects for various aberrations and different pupil diameters. It is shown that for small pupils the double-pass effects are negligible. The testing and alignment of aberrometer was performed using the schematic eye, developed in our lab. We also introduced a model of human eye based on bimorph flexible mirror. We perform calculations to demonstrate that our schematic eye is capable of reproducing spatial-temporal statistics of aberrations of living eye with normal vision or even myopic or hypermetropic or with high aberrations ones.
Hanneken, Anne; Neikirk, Thomas; Johnson, Jennifer; Kono, Masahiro
2017-08-01
To test the hypothesis that delayed dark adaptation in patients with macular degeneration is due to an excess of free unliganded opsin (apo-opsin) and a deficiency of the visual chromophore, 11 -cis retinal, in rod outer segments. A total of 50 human autopsy eyes were harvested from donors with and without macular degeneration within 2-24 hrs. postmortem. Protocols were developed which permitted dark adaptation of normal human eyes after death and enucleation. Biochemical methods of purifying rod outer segments were optimized and the concentration of rhodopsin and apo-opsin was measured with UV-visible scanning spectroscopy. The presence of apo-opsin was calculated by measuring the difference in the rhodopsin absorption spectra before and after the addition of 11 -cis retinal. A total of 20 normal eyes and 16 eyes from donors with early, intermediate and advanced stages of macular degeneration were included in the final analysis. Dark adaptation was achieved by harvesting whole globes in low light, transferring into dark (light-proof) canisters and dissecting the globes using infrared light and image converters for visualization. Apo-opsin was readily detected in positive controls after the addition of 11 -cis retinal. Normal autopsy eyes showed no evidence of apo-opsin. Eyes with macular degeneration also showed no evidence of apo-opsin, regardless of the severity of disease. Methods have been developed to study dark adaptation in human autopsy eyes. Eyes with age-related macular degeneration do not show a deficiency of 11 -cis retinal or an excess of apo-opsin within rod outer segments.
Corneal polarimetry after LASIK refractive surgery
NASA Astrophysics Data System (ADS)
Bueno, Juan M.; Berrio, Esther; Artal, Pablo
2006-01-01
Imaging polarimetry provides spatially resolved information on the polarization properties of a system. In the case of the living human eye, polarization could be related to the corneal biomechanical properties, which vary from the normal state as a result of surgery or pathologies. We have used an aberro-polariscope, which we recently developed, to determine and to compare the spatially resolved maps of polarization parameters across the pupil between normal healthy and post-LASIK eyes. The depolarization distribution is not uniform across the pupil, with post-surgery eyes presenting larger levels of depolarization. While retardation increases along the radius in normal eyes, this pattern becomes irregular after LASIK refractive surgery. The maps of slow axis also differ in normal and post-surgery eyes, with a larger disorder in post-LASIK eyes. Since these changes in polarization indicate subtle structural modifications of the cornea, this approach can be useful in a clinical environment to follow the biomechanical and optical changes of the cornea after refractive surgery or for the early diagnosis of different corneal pathologies.
NASA Technical Reports Server (NTRS)
Leigh, R. J.; Thurston, S. E.; Sharpe, J. A.; Ranalli, P. J.; Hamid, M. A.
1987-01-01
The effects of deficient labyrinthine function on smooth visual tracking with the eyes and head were investigated, using ten patients with bilateral peripheral vestibular disease and ten normal controls. Active, combined eye-head tracking (EHT) was significantly better in patients than smooth pursuit with the eyes alone, whereas normal subjects pursued equally well in both cases. Compensatory eye movements during active head rotation in darkness were always less in patients than in normal subjects. These data were used to examine current hypotheses that postulate central cancellation of the vestibulo-ocular reflex (VOR) during EHT. A model that proposes summation of an integral smooth pursuit command and VOR/compensatory eye movements is consistent with the findings. Observation of passive EHT (visual fixation of a head-fixed target during en bloc rotation) appears to indicate that in this mode parametric gain changes contribute to modulation of the VOR.
Nystagmus responses in a group of normal humans during earth-horizontal axis rotation
NASA Technical Reports Server (NTRS)
Wall, Conrad, III; Furman, Joseph M. R.
1989-01-01
Horizontal eye movement responses to earth-horizontal yaw axis rotation were evaluated in 50 normal human subjects who were uniformly distributed in age (20-69 years) and each age group was then divided by gender. Subjects were rotated with eyes open in the dark, using clockwise and counter-clockwise 60 deg velocity trapezoids. The nystagmus slow component velocity is analyzed. It is shown that, despite large intersubject variability, parameters which describe earth-horizontal yaw axis responses are loosely interrelated, and some of them vary significantly with gender and age.
Benzodiazepine sensitivity in normal human subjects.
Hommer, D W; Matsuo, V; Wolkowitz, O; Chrousos, G; Greenblatt, D J; Weingartner, H; Paul, S M
1986-06-01
Increasing intravenous doses of diazepam or placebo were administered to ten healthy normal volunteers, and the changes in saccadic eye velocity, self-rated sedation and anxiety, and plasma cortisol and growth hormone concentrations were measured. Diazepam administration (4.4 to 140 micrograms/kg, cumulative dose) resulted in a dose-dependent decrease in saccadic eye velocity and plasma cortisol level as well as a dose-dependent increase in self-rated sedation and plasma growth hormone level. Self-rated anxiety was unaffected in these relatively nonanxious subjects. The diazepam-induced changes in saccadic eye velocity, sedation, and growth hormone and cortisol levels were highly correlated with each other and with increasing plasma diazepam concentration. These results are consistent with a benzodiazepine receptor-mediated action of diazepam. The highly quantifiable and dose-dependent decrease in saccadic eye velocity by benzodiazepines should make this a useful measure of benzodiazepine receptor sensitivity in humans.
Adaptations and deficits in the vestibulo-ocular reflex after sixth nerve palsy.
Wong, Agnes M F; Tweed, Douglas; Sharpe, James A
2002-01-01
The effects of paralytic strabismus on the vestibulo-ocular reflex (VOR) have not been systematically investigated in humans. The purpose of this study was to analyze the VOR in patients with unilateral peripheral sixth nerve palsy. Twenty-one patients with unilateral peripheral sixth nerve palsy (6 severe, 7 moderate, 8 mild) and 15 normal subjects were studied. Subjects made sinusoidal +/-10 degrees head-on-body rotations in yaw and pitch at approximately 0.5 and 2 Hz, and in roll at approximately 0.5, 1, and 2 Hz. Eye movement recordings were obtained using magnetic scleral search coils in each eye in darkness and during monocular viewing in light. Static torsional VOR gains, defined as change in torsional eye position divided by change in head position during sustained head roll, were also measured. In all patients, horizontal VOR gains in darkness were decreased in the paretic eye in both abduction and adduction, but remained normal in the nonparetic eye in both directions. In light, horizontal visually enhanced VOR (VVOR) gains were normal in both eyes in moderate and mild palsy. In severe palsy, horizontal VVOR gains remained low in the paretic eye during viewing with either eye, whereas those in the nonparetic eye were higher than normal when the paretic eye viewed. Vertical VOR and VVOR were normal, but dynamic and static torsional VOR and VVOR gains were reduced in both eyes in all patients. In darkness, horizontal VOR gains were reduced during abduction of the paretic eye in all patients, as anticipated in sixth nerve palsy. Gains were also reduced during adduction of the paretic eye, suggesting that innervation to the medial rectus has changed. After severe palsy, vision did not increase abducting or adducting horizontal VVOR gains to normal in the paretic eye, but caused secondary increase in VVOR gains to values above unity in the nonparetic eye, when the paretic eye fixated. In mild and moderate palsy, vision enhanced the VOR in the paretic eye but caused no change in the nonparetic eye, suggesting a monocular readjustment of innervation selectively to the paretic eye. Vertical VOR and VVOR gains were normal, indicating that the lateral rectus did not have significant vertical actions through the excursions that we tested (+/-10 degrees ). Reduced torsional VOR gains in the paretic eye can be explained by the esotropia in sixth nerve palsy. Torsional VOR gain normally varies with vergence. We attribute the reduced torsional gains in the paretic eye to the mechanism that normally lowers it during convergence. The low torsional gains in the nonparetic eye may be an adaptation to reduce torsional disparity between the two eyes.
Estimating Human Trabecular Meshwork Stiffness by Numerical Modeling and Advanced OCT Imaging.
Wang, Ke; Johnstone, Murray A; Xin, Chen; Song, Shaozhen; Padilla, Steven; Vranka, Janice A; Acott, Ted S; Zhou, Kai; Schwaner, Stephen A; Wang, Ruikang K; Sulchek, Todd; Ethier, C Ross
2017-09-01
The purpose of this study was to estimate human trabecular meshwork (hTM) stiffness, thought to be elevated in glaucoma, using a novel indirect approach, and to compare results with direct en face atomic force microscopy (AFM) measurements. Postmortem human eyes were perfused to measure outflow facility and identify high- and low-flow regions (HF, LF) by tracer. Optical coherence tomography (OCT) images were obtained as Schlemm's canal luminal pressure was directly manipulated. TM stiffness was deduced by an inverse finite element modeling (FEM) approach. A series of AFM forcemaps was acquired along a line traversing the anterior angle on a radially cut flat-mount corneoscleral wedge with TM facing upward. The elastic modulus of normal hTM estimated by inverse FEM was 70 ± 20 kPa (mean ± SD), whereas glaucomatous hTM was slightly stiffer (98 ± 19 kPa). This trend was consistent with TM stiffnesses measured by AFM: normal hTM stiffness = 1.37 ± 0.56 kPa, which was lower than glaucomatous hTM stiffness (2.75 ± 1.19 kPa). None of these differences were statistically significant. TM in HF wedges was softer than that in LF wedges for both normal and glaucomatous eyes based on the inverse FEM approach but not by AFM. Outflow facility was significantly correlated with TM stiffness estimated by FEM in six human eyes (P = 0.018). TM stiffness is higher, but only modestly so, in glaucomatous patients. Outflow facility in both normal and glaucomatous human eyes appears to associate with TM stiffness. This evidence motivates further studies to investigate factors underlying TM biomechanical property regulation.
Holocamera for 3-D micrography of the alert human eye
NASA Astrophysics Data System (ADS)
Tokuda, A. R.; Auth, D. C.; Bruckner, A. P.
1980-07-01
A holocamera that safely records holograms of the full depth of the alert human eye with a spatial resolution of about 20 microns is described. A single-mode argon-ion laser generating 2 W at 5145 A serves as the illuminating source. Holographic exposure times of 0.3 msec are achieved by means of a fail-safe electromechanical shutter system. Integrated retinal irradiance levels are well under the American National Standards Institute safety standards. Reconstructed real images are projected directly onto the vidicon faceplate of a closed-circuit TV system, enabling convenient scanning in the x-y-z dimensions of the reconstructed eyeball. Serially reconstructed holograms of cataractous rabbit eyes and normal human eyes are presented.
Genes relacionados con microftalmia y anoftalmia hereditarias.
Matías-Pérez, Diana; García-Montalvo, Iván Antonio; Zenteno, Juan Carlos
2017-01-01
Congenital eye malformations are the second most common cause of childhood blindness and are originated by disruption of the normal process of eye development during embryonic stage. Their etiology is variable, although monogenic causes are of great importance as they have a high risk of familial recurrence. Included among the most severe congenital eye abnormalities are microphthalmia, defined by an abnormally small eye, and anophthalmia, characterized by congenital absence of ocular structures. The currrent knowledge of the genes involved in human microphthalmia and anophthalmia in humans is revised in this work. Copyright: © 2017 SecretarÍa de Salud.
Eye and head motion during head turns in spaceflight
NASA Technical Reports Server (NTRS)
Thornton, William E.; Uri, John J.; Moore, Thomas P.; Pool, Sam L.
1988-01-01
Eye-head motion was studied pre-, in- and postflight during single voluntary head turns. A transient increase in vestibulo-ocular reflex (VOR) gain occurred early in the flight, but later trended toward normal. This increased gain was produced by a relative increase in eye counterrotation velocity. Asymmetries in gain with right and left turns also occurred, caused by asymmetries in eye counterrotation velocities. These findings were remarkably similar to those from Soviet primate studies using gaze fixation targets, except the human study trended more rapidly toward normal. These findings differ substantially from those measuring VOR gain by head oscillation, in which no significant changes were found inflight. No visual disturbances were noted in either test condition or in normal activities. These head turn studies are the only ones to date documenting any functional change in VOR in weightlessness.
Latent binocular function in amblyopia.
Chadnova, Eva; Reynaud, Alexandre; Clavagnier, Simon; Hess, Robert F
2017-11-01
Recently, psychophysical studies have shown that humans with amblyopia do have binocular function that is not normally revealed due to dominant suppressive interactions under normal viewing conditions. Here we use magnetoencephalography (MEG) combined with dichoptic visual stimulation to investigate the underlying binocular function in humans with amblyopia for stimuli that, because of their temporal properties, would be expected to bypass suppressive effects and to reveal any underlying binocular function. We recorded contrast response functions in visual cortical area V1 of amblyopes and normal observers using a steady state visually evoked responses (SSVER) protocol. We used stimuli that were frequency-tagged at 4Hz and 6Hz that allowed identification of the responses from each eye and were of a sufficiently high temporal frequency (>3Hz) to bypass suppression. To characterize binocular function, we compared dichoptic masking between the two eyes in normal and amblyopic participants as well as interocular phase differences in the two groups. We observed that the primary visual cortex responds less to the stimulation of the amblyopic eye compared to the fellow eye. The pattern of interaction in the amblyopic visual system however was not significantly different between the amblyopic and fellow eyes. However, the amblyopic suppressive interactions were lower than those observed in the binocular system of our normal observers. Furthermore, we identified an interocular processing delay of approximately 20ms in our amblyopic group. To conclude, when suppression is greatly reduced, such as the case with our stimulation above 3Hz, the amblyopic visual system exhibits a lack of binocular interactions. Copyright © 2017 Elsevier Ltd. All rights reserved.
Visual optics: an engineering approach
NASA Astrophysics Data System (ADS)
Toadere, Florin
2010-11-01
The human eyes' visual system interprets the information from the visible light in order to build a representation of the world surrounding the body. It derives color by comparing the responses to light from the three types of photoreceptor cones in the eyes. These long medium and short cones are sensitive to blue, green and red portions of the visible spectrum. We simulate the color vision for the normal eyes. We see the effects of the dyes, filters, glasses and windows on color perception when the test image is illuminated with the D65 light sources. In addition to colors' perception, the human eyes can suffer from diseases and disorders. The eye can be seen as an optical instrument which has its own eye print. We present aspects of some nowadays methods and technologies which can capture and correct the human eyes' wavefront aberrations. We focus our attention to Siedel aberrations formula, Zenike polynomials, Shack-Hartmann Sensor, LASIK, interferograms fringes aberrations and Talbot effect.
High-speed adaptive optics line scan confocal retinal imaging for human eye.
Lu, Jing; Gu, Boyu; Wang, Xiaolin; Zhang, Yuhua
2017-01-01
Continuous and rapid eye movement causes significant intraframe distortion in adaptive optics high resolution retinal imaging. To minimize this artifact, we developed a high speed adaptive optics line scan confocal retinal imaging system. A high speed line camera was employed to acquire retinal image and custom adaptive optics was developed to compensate the wave aberration of the human eye's optics. The spatial resolution and signal to noise ratio were assessed in model eye and in living human eye. The improvement of imaging fidelity was estimated by reduction of intra-frame distortion of retinal images acquired in the living human eyes with frame rates at 30 frames/second (FPS), 100 FPS, and 200 FPS. The device produced retinal image with cellular level resolution at 200 FPS with a digitization of 512×512 pixels/frame in the living human eye. Cone photoreceptors in the central fovea and rod photoreceptors near the fovea were resolved in three human subjects in normal chorioretinal health. Compared with retinal images acquired at 30 FPS, the intra-frame distortion in images taken at 200 FPS was reduced by 50.9% to 79.7%. We demonstrated the feasibility of acquiring high resolution retinal images in the living human eye at a speed that minimizes retinal motion artifact. This device may facilitate research involving subjects with nystagmus or unsteady fixation due to central vision loss.
Abnormal spatial frequency channels in esotropic cats.
Holopigian, K; Blake, R
1984-01-01
A noise masking paradigm was used to measure spatial tuning for the deviating and nondeviating eyes of two esotropic cats and for one eye of a control cat. With increasing noise contrast, masking grew more slowly for both the deviating and the nondeviating eyes of the esotropic cats than for the control cat; apparently, contrast coding is impaired for both eyes of the esotropic cats. Masking with band-reject filtered noise indicated that detection channels for either eye of the esotropic cats were twice as broadly tuned as those for the control cat. In a subsequent experiment, the spatial tuning characteristics of two human esotropes were found to be normal, indicating a fundamental difference between human esotropia and esotropia induced in cats by the section of an eye muscle.
Estimation of the mechanical properties of the eye through the study of its vibrational modes.
Aloy, M Á; Adsuara, J E; Cerdá-Durán, P; Obergaulinger, M; Esteve-Taboada, J J; Ferrer-Blasco, T; Montés-Micó, R
2017-01-01
Measuring the eye's mechanical properties in vivo and with minimally invasive techniques can be the key for individualized solutions to a number of eye pathologies. The development of such techniques largely relies on a computational modelling of the eyeball and, it optimally requires the synergic interplay between experimentation and numerical simulation. In Astrophysics and Geophysics the remote measurement of structural properties of the systems of their realm is performed on the basis of (helio-)seismic techniques. As a biomechanical system, the eyeball possesses normal vibrational modes encompassing rich information about its structure and mechanical properties. However, the integral analysis of the eyeball vibrational modes has not been performed yet. Here we develop a new finite difference method to compute both the spheroidal and, specially, the toroidal eigenfrequencies of the human eye. Using this numerical model, we show that the vibrational eigenfrequencies of the human eye fall in the interval 100 Hz-10 MHz. We find that compressible vibrational modes may release a trace on high frequency changes of the intraocular pressure, while incompressible normal modes could be registered analyzing the scattering pattern that the motions of the vitreous humour leave on the retina. Existing contact lenses with embebed devices operating at high sampling frequency could be used to register the microfluctuations of the eyeball shape we obtain. We advance that an inverse problem to obtain the mechanical properties of a given eye (e.g., Young's modulus, Poisson ratio) measuring its normal frequencies is doable. These measurements can be done using non-invasive techniques, opening very interesting perspectives to estimate the mechanical properties of eyes in vivo. Future research might relate various ocular pathologies with anomalies in measured vibrational frequencies of the eye.
Marijuana smoking and reduced pressure in human eyes: drug action or epiphenomenon?
Flom, M C; Adams, A J; Jones, R T
1975-01-01
Normal pressure within the human eye was reduced after smoking a socially relevant dose of marijuana (12 mg. delta9-9-tetrahydrocannabinol), but only for light to moderate users who experienced a substantial "high" and a state of peaceful relaxation from the experimental dose. Analysis suggests an indirect effect of the drug associated with relaxation-a psychophysiologic state that can be produced by drug and nondrug means.
Zhai, Yi; Wang, Yan; Wang, Zhaoqi; Liu, Yongji; Zhang, Lin; He, Yuanqing; Chang, Shengjiang
2014-01-01
An achromatic element eliminating only longitudinal chromatic aberration (LCA) while maintaining transverse chromatic aberration (TCA) is established for the eye model, which involves the angle formed by the visual and optical axis. To investigate the impacts of higher-order aberrations on vision, the actual data of higher-order aberrations of human eyes with three typical levels are introduced into the eye model along visual axis. Moreover, three kinds of individual eye models are established to investigate the impacts of higher-order aberrations, chromatic aberration (LCA+TCA), LCA and TCA on vision under the photopic condition, respectively. Results show that for most human eyes, the impact of chromatic aberration on vision is much stronger than that of higher-order aberrations, and the impact of LCA in chromatic aberration dominates. The impact of TCA is approximately equal to that of normal level higher-order aberrations and it can be ignored when LCA exists.
Migliaccio, Americo A; Cremer, Phillip D; Aw, Swee T; Halmagyi, G Michael; Curthoys, Ian S; Minor, Lloyd B; Todd, Michael J
2003-07-01
The aim of this study was to determine whether vergence-mediated changes in the axis of eye rotation in the human vestibulo-ocular reflex (VOR) would obey Listing's Law (normally associated with saccadic eye movements) independent of the initial eye position. We devised a paradigm for disassociating the saccadic velocity axis from eye position by presenting near and far targets that were centered with respect to one eye. We measured binocular 3-dimensional eye movements using search coils in ten normal subjects and 3-dimensional linear head acceleration using Optotrak in seven normal subjects. The stimuli consisted of passive, unpredictable, pitch head rotations with peak acceleration of approximately 2000 degrees /s(2 )and amplitude of approximately 20 degrees. During the pitch head rotation, each subject fixated straight ahead with one eye, whereas the other eye was adducted 4 degrees during far viewing (94 cm) and 25 degrees during near viewing (15 cm). Our data showed expected compensatory pitch rotations in both eyes, and a vergence-mediated horizontal rotation only in the adducting eye. In addition, during near viewing we observed torsional eye rotations not only in the adducting eye but also in the eye looking straight ahead. In the straight-ahead eye, the change in torsional eye velocity between near and far viewing, which began approximately 40 ms after the start of head rotation, was 10+/-6 degrees /s (mean +/- SD). This change in torsional eye velocity resulted in a 2.4+/-1.5 degrees axis tilt toward Listing's plane in that eye. In the adducting eye, the change in torsional eye velocity between near and far viewing was 16+/-6 degrees /s (mean +/- SD) and resulted in a 4.1+/-1.4 degrees axis tilt. The torsional eye velocities were conjugate and both eyes partially obeyed Listing's Law. The axis of eye rotation tilted in the direction of the line of sight by approximately one-third of the angle between the line of sight and a line orthogonal to Listing's plane. This tilt was higher than predicted by the one-quarter rule. The translational acceleration component of the pitch head rotation measured 0.5 g and may have contributed to the increased torsional component observed during near viewing. Our data show that vergence-mediated eye movements obey a VOR/Listing's Law compromise strategy independent of the initial eye position.
High-speed adaptive optics line scan confocal retinal imaging for human eye
Wang, Xiaolin; Zhang, Yuhua
2017-01-01
Purpose Continuous and rapid eye movement causes significant intraframe distortion in adaptive optics high resolution retinal imaging. To minimize this artifact, we developed a high speed adaptive optics line scan confocal retinal imaging system. Methods A high speed line camera was employed to acquire retinal image and custom adaptive optics was developed to compensate the wave aberration of the human eye’s optics. The spatial resolution and signal to noise ratio were assessed in model eye and in living human eye. The improvement of imaging fidelity was estimated by reduction of intra-frame distortion of retinal images acquired in the living human eyes with frame rates at 30 frames/second (FPS), 100 FPS, and 200 FPS. Results The device produced retinal image with cellular level resolution at 200 FPS with a digitization of 512×512 pixels/frame in the living human eye. Cone photoreceptors in the central fovea and rod photoreceptors near the fovea were resolved in three human subjects in normal chorioretinal health. Compared with retinal images acquired at 30 FPS, the intra-frame distortion in images taken at 200 FPS was reduced by 50.9% to 79.7%. Conclusions We demonstrated the feasibility of acquiring high resolution retinal images in the living human eye at a speed that minimizes retinal motion artifact. This device may facilitate research involving subjects with nystagmus or unsteady fixation due to central vision loss. PMID:28257458
The Stiles-Crawford Effect: spot-size ratio departure in retinitis pigmentosa
NASA Astrophysics Data System (ADS)
Sharma, Nachieketa K.; Lakshminarayanan, Vasudevan
2016-04-01
The Stiles-Crawford effect of the first kind is the retina's compensative response to loss of luminance efficiency for oblique stimulation manifested as the spot-size ratio departure from the perfect power coupling for a normal human eye. In a retinitis pigmentosa eye (RP), the normal cone photoreceptor morphology is affected due to foveal cone loss and disrupted cone mosaic spatial arrangement with reduction in directional sensitivity. We show that the flattened Stiles-Crawford function (SCF) in a RP eye is due to a different spot-size ratio departure profile, that is, for the same loss of luminance efficiency, a RP eye has a smaller departure from perfect power coupling compared to a normal eye. Again, the difference in spot-size ratio departure increases from the centre towards the periphery, having zero value for axial entry and maximum value for maximum peripheral entry indicating dispersal of photoreceptor alignment which prevents the retina to go for a bigger compensative response as it lacks both in number and appropriate cone morphology to tackle the loss of luminance efficiency for oblique stimulation. The slope of departure profile also testifies to the flattened SCF for a RP eye. Moreover, the discrepancy in spot-size ratio departure between a normal and a RP eye is shown to have a direct bearing on the Stiles-Crawford diminution of visibility.
Kotani, Manato; Shimono, Kohei; Yoneyama, Toshihiro; Nakako, Tomokazu; Matsumoto, Kenji; Ogi, Yuji; Konoike, Naho; Nakamura, Katsuki; Ikeda, Kazuhito
2017-09-01
Eye tracking systems are used to investigate eyes position and gaze patterns presumed as eye contact in humans. Eye contact is a useful biomarker of social communication and known to be deficient in patients with autism spectrum disorders (ASDs). Interestingly, the same eye tracking systems have been used to directly compare face scanning patterns in some non-human primates to those in human. Thus, eye tracking is expected to be a useful translational technique for investigating not only social attention and visual interest, but also the effects of psychiatric drugs, such as oxytocin, a neuropeptide that regulates social behavior. In this study, we report on a newly established method for eye tracking in common marmosets as unique New World primates that, like humans, use eye contact as a mean of communication. Our investigation was aimed at characterizing these primates face scanning patterns and evaluating the effects of oxytocin on their eye contact behavior. We found that normal common marmosets spend more time viewing the eyes region in common marmoset's picture than the mouth region or a scrambled picture. In oxytocin experiment, the change in eyes/face ratio was significantly greater in the oxytocin group than in the vehicle group. Moreover, oxytocin-induced increase in the change in eyes/face ratio was completely blocked by the oxytocin receptor antagonist L-368,899. These results indicate that eye tracking in common marmosets may be useful for evaluating drug candidates targeting psychiatric conditions, especially ASDs. Copyright © 2017 Elsevier Ltd. All rights reserved.
Dry eye symptoms are increased in mice deficient in phospholipid transfer protein (PLTP).
Setälä, Niko L; Metso, Jari; Jauhiainen, Matti; Sajantila, Antti; Holopainen, Juha M
2011-05-01
In the tear fluid the outermost part facing the tear-air interface is composed of lipids preventing evaporation of the tears. Phospholipid transfer protein (PLTP) mediates phospholipid transfer processes between serum lipoproteins and is also a normal component of human tears. To study whether PLTP plays any functional role in tear fluid we investigated PLTP-deficient mice, applying functional and morphologic analyses under normal housing and experimentally induced dry eye conditions. Aqueous tear fluid production, corneal epithelial morphology, barrier function, and occludin expression were assessed. In mice with a full deficiency of functional PLTP enhanced corneal epithelial damage, increased corneal permeability to carboxyfluorescein, and decreased corneal epithelial occludin expression were shown. These pathologic signs were worsened by experimentally induced dry eye both in wild-type and PLTP knock-out mice. Deficiency in the production of tear PLTP in mice is accompanied by corneal epithelial damage, a feature that is typical in human dry eye syndrome (DES). To complement animal experiments we collected tear fluid from human dry eye patients as well as healthy control subjects. Increased tear fluid PLTP activity was observed among DES patients. In conclusion, the presence of PLTP in tear fluid appears to be essential for maintaining a healthy and functional ocular surface. Increased PLTP activity in human tear fluid in DES patients suggests an ocular surface protective role for this lipid transfer protein. Copyright © 2011 American Society for Investigative Pathology. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Shi, Guohua; Wang, Fei; Li, Xiqi; Lu, Jing; Ding, Zhihua; Sun, Xinghuai; Jiang, Chunhui; Zhang, Yudong
2012-01-01
We have used anterior segment swept source optical coherence tomography to measure Schlemm's canal (SC) morphometric values in the living human eye. Fifty healthy volunteers with 100 normal eyes were measured in the nasal and temporal side. Comparison with the published SC morphometric values of histologic sections proves the reliability of our results. The statistical results show that there are no significant differences between nasal and temporal SC with respect to their diameter, perimeter, and area in our study (diameter: t=0.122, p=0.903; perimeter: t=-0.003, p=0.998; area: t=-1.169, p=0.244); further, no significant differences in SC morphometric values are found between oculus sinister and oculus dexter (diameter: t=0.943, p=0.35; perimeter: t=1.346, p=0.18; area: t=1.501, p=0.135).
Sinskey, Robert M; Eshete, Almaz
2002-01-01
To evaluate the visual and restoration of normal appearance results of maximal excision of the horizontal rectus muscles in nystagmus patients. Menelik II Hospital, Addis Ababa, Ethiopia and the Sinskey Eye Institute, Santa Monica, California. The medial and lateral rectus muscles were extirpated as far back as possible with an enucleation snare in four patients with horizontal nystagmus. A complete eye examination was performed pre- and postoperatively. Using a camcorder, ocular movements were recorded before surgery, and at postop; days 1 and 40, and months 1, 3 and 10. All four patients had a marked reduction in both abnormal and normal horizontal eye movement, and improvement in objective visual acuity. Postoperative residual intermittent fine horizontal movement was recorded in the left eye in a 6 year old and in both eyes of a 41 year old patient. A residual rotary component was recorded in a 15 year-old patient. The 6 and 9 year-old patients each developed a moderate exotropia. The 15 and 41 year-old patients maintained binocular fusion with some residual ability to converge. Vision increased subjectively in all cases. Subtotal myectomy of the horizontal muscles in horizontal nystagmus with no null point was very effective in improving and/or eliminating horizontal eye movement. Restoration of normal or near normal appearance and improvement in visual acuity occurred in all cases. None of the patients complained of their loss of horizontal gaze and eye movement. More complete myectomy of the muscles should produce total elimination of both normal and abnormal horizontal eye movement including nystagmus.
Estimation of the mechanical properties of the eye through the study of its vibrational modes
2017-01-01
Measuring the eye’s mechanical properties in vivo and with minimally invasive techniques can be the key for individualized solutions to a number of eye pathologies. The development of such techniques largely relies on a computational modelling of the eyeball and, it optimally requires the synergic interplay between experimentation and numerical simulation. In Astrophysics and Geophysics the remote measurement of structural properties of the systems of their realm is performed on the basis of (helio-)seismic techniques. As a biomechanical system, the eyeball possesses normal vibrational modes encompassing rich information about its structure and mechanical properties. However, the integral analysis of the eyeball vibrational modes has not been performed yet. Here we develop a new finite difference method to compute both the spheroidal and, specially, the toroidal eigenfrequencies of the human eye. Using this numerical model, we show that the vibrational eigenfrequencies of the human eye fall in the interval 100 Hz–10 MHz. We find that compressible vibrational modes may release a trace on high frequency changes of the intraocular pressure, while incompressible normal modes could be registered analyzing the scattering pattern that the motions of the vitreous humour leave on the retina. Existing contact lenses with embebed devices operating at high sampling frequency could be used to register the microfluctuations of the eyeball shape we obtain. We advance that an inverse problem to obtain the mechanical properties of a given eye (e.g., Young’s modulus, Poisson ratio) measuring its normal frequencies is doable. These measurements can be done using non-invasive techniques, opening very interesting perspectives to estimate the mechanical properties of eyes in vivo. Future research might relate various ocular pathologies with anomalies in measured vibrational frequencies of the eye. PMID:28922351
Looking at Images with Human Figures: Comparison between Autistic and Normal Children.
ERIC Educational Resources Information Center
van der Geest, J. N.; Kemner, C.; Camfferman, G.; Verbaten, M. N.; van Engeland, H.
2002-01-01
In this study, the looking behavior of 16 autistic and 14 non-autistic children toward cartoon-like scenes that included a human figure was measured quantitatively using an infrared eye-tracking device. Fixation behavior of autistic children was similar to that of their age-and IQ-matched normal peers. Results do not support the idea that autistic…
Correcting highly aberrated eyes using large-stroke adaptive optics.
Sabesan, Ramkumar; Ahmad, Kamran; Yoon, Geunyoung
2007-11-01
To investigate the optical performance of a large-stroke deformable mirror in correcting large aberrations in highly aberrated eyes. A large-stroke deformable mirror (Mirao 52D; Imagine Eyes) and a Shack-Hartmann wavefront sensor were used in an adaptive optics system. Closed-loop correction of the static aberrations of a phase plate designed for an advanced keratoconic eye was performed for a 6-mm pupil. The same adaptive optics system was also used to correct the aberrations in one eye each of two moderate keratoconic and three normal human eyes for a 6-mm pupil. With closed-loop correction of the phase plate, the total root-mean-square (RMS) over a 6-mm pupil was reduced from 3.54 to 0.04 microm in 30 to 40 iterations, corresponding to 3 to 4 seconds. Adaptive optics closed-loop correction reduced an average total RMS of 1.73+/-0.998 to 0.10+/-0.017 microm (higher order RMS of 0.39+/-0.124 to 0.06+/-0.004 microm) in the three normal eyes and 2.73+/-1.754 to 0.10+/-0.001 microm (higher order RMS of 1.82+/-1.058 to 0.05+/-0.017 microm) in the two keratoconic eyes. Aberrations in both normal and highly aberrated eyes were successfully corrected using the large-stroke deformable mirror to provide almost perfect optical quality. This mirror can be a powerful tool to assess the limit of visual performance achievable after correcting the aberrations, especially in eyes with abnormal corneal profiles.
Three-Dimensional Eye Tracking in a Surgical Scenario.
Bogdanova, Rositsa; Boulanger, Pierre; Zheng, Bin
2015-10-01
Eye tracking has been widely used in studying the eye behavior of surgeons in the past decade. Most eye-tracking data are reported in a 2-dimensional (2D) fashion, and data for describing surgeons' behaviors on stereoperception are often missed. With the introduction of stereoscopes in laparoscopic procedures, there is an increasing need for studying the depth perception of surgeons under 3D image-guided surgery. We developed a new algorithm for the computation of convergence points in stereovision by measuring surgeons' interpupillary distance, the distance to the view target, and the difference between gaze locations of the 2 eyes. To test the feasibility of our new algorithm, we recruited 10 individuals to watch stereograms using binocular disparity and asked them to develop stereoperception using a cross-eyed viewing technique. Participants' eye motions were recorded by the Tobii eye tracker while they performed the trials. Convergence points between normal and stereo-viewing conditions were computed using the developed algorithm. All 10 participants were able to develop stereovision after a short period of training. During stereovision, participants' eye convergence points were 14 ± 1 cm in front of their eyes, which was significantly closer than the convergence points under the normal viewing condition (77 ± 20 cm). By applying our method of calculating convergence points using eye tracking, we were able to elicit the eye movement patterns of human operators between the normal and stereovision conditions. Knowledge from this study can be applied to the design of surgical visual systems, with the goal of improving surgical performance and patient safety. © The Author(s) 2015.
Adaptive Optics for the Human Eye
NASA Astrophysics Data System (ADS)
Williams, D. R.
2000-05-01
Adaptive optics can extend not only the resolution of ground-based telescopes, but also the human eye. Both static and dynamic aberrations in the cornea and lens of the normal eye limit its optical quality. Though it is possible to correct defocus and astigmatism with spectacle lenses, higher order aberrations remain. These aberrations blur vision and prevent us from seeing at the fundamental limits set by the retina and brain. They also limit the resolution of cameras to image the living retina, cameras that are a critical for the diagnosis and treatment of retinal disease. I will describe an adaptive optics system that measures the wave aberration of the eye in real time and compensates for it with a deformable mirror, endowing the human eye with unprecedented optical quality. This instrument provides fresh insight into the ultimate limits on human visual acuity, reveals for the first time images of the retinal cone mosaic responsible for color vision, and points the way to contact lenses and laser surgical methods that could enhance vision beyond what is currently possible today. Supported by the NSF Science and Technology Center for Adaptive Optics, the National Eye Institute, and Bausch and Lomb, Inc.
Objective evaluation of the visual acuity in human eyes
NASA Astrophysics Data System (ADS)
Rosales, M. A.; López-Olazagasti, E.; Ramírez-Zavaleta, G.; Varillas, G.; Tepichín, E.
2009-08-01
Traditionally, the quality of the human vision is evaluated by a subjective test in which the examiner asks the patient to read a series of characters of different sizes, located at a certain distance of the patient. Typically, we need to ensure a subtended angle of vision of 5 minutes, which implies an object of 8.8 mm high located at 6 meters (normal or 20/20 visual acuity). These characters constitute what is known as the Snellen chart, universally used to evaluate the spatial resolution of the human eyes. The mentioned process of identification of characters is carried out by means of the eye - brain system, giving an evaluation of the subjective visual performance. In this work we consider the eye as an isolated image-forming system, and show that it is possible to isolate the function of the eye from that of the brain in this process. By knowing the impulse response of the eye´s system we can obtain, in advance, the image of the Snellen chart simultaneously. From this information, we obtain the objective performance of the eye as the optical system under test. This type of results might help to detect anomalous situations of the human vision, like the so called "cerebral myopia".
Mucin-type O-glycans in Tears of Normal Subjects and Patients with Non-Sjögren’s Dry Eye
Guzman-Aranguez, Ana; Mantelli, Flavio; Argüeso, Pablo
2009-01-01
Purpose O-linked carbohydrates (O-glycans) contribute to the hydrophilic character of mucins in mucosal tissues. This study aimed to identify the repertoire of O-glycans in the tear film, and the glycosyltransferases associated with their biosynthesis, in normal subjects and patients with non-Sjögren’s dry eye. Methods Human tear fluid was collected from the inferior conjunctival fornix. O-glycans were released by hydrazinolysis, labeled with 2-aminobenzamide, and analyzed by fluorometric, high-performance liquid chromatography (HPLC) coupled with exoglycosidase digestions. O-glycan structures identified in tears were related to potential biosynthetic pathways in human conjunctival epithelium using a glycogene microarray database. Lectin-binding analyses were performed using agglutinins from Arachis hypogaea, Maackia amurensis, and Sambucus nigra. Results The O-glycan profile of human tears consisted primarily of core 1 (Galβ1-3GalNAcα1-Ser/Thr)-based structures. Mono-sialyl O-glycans represented approximately 66% of the glycan pool, being α2-6-sialyl core 1 the predominant O-glycan structure in human tears (48%). Four families of glycosyltranferases potentially related to the biosynthesis of these structures were identified in human conjunctiva. These included thirteen polypeptide-GalNAc-transferases (GALNT), the core 1 β-3-galactosyltransferase (T-synthase), three α2-6-sialyltransferases (ST6GalNAc), and two α2-3-sialyltransferases (ST3Gal). No significant differences in total amount of O-glycans were detected between tears of normal subjects and dry eye patients, by HPLC and lectin blot. Likewise, no differences in glycosyltransferase expression were found by glycogene microarray. Conclusions This study identifies the most common mucin-type O-glycans in human tears and their expected biosynthetic pathways in ocular surface epithelia. Patients with non-Sjögren’s dry eye show no alterations in composition and amount of O-glycans in the tear fluid. PMID:19407012
Hahn, Paul; Migacz, Justin; O'Connell, Rachelle; Izatt, Joseph A; Toth, Cynthia A
2013-01-01
We have recently developed a microscope-integrated spectral-domain optical coherence tomography (MIOCT) device towards intrasurgical cross-sectional imaging of surgical maneuvers. In this report, we explore the capability of MIOCT to acquire real-time video imaging of vitreoretinal surgical maneuvers without post-processing modifications. Standard 3-port vitrectomy was performed in human during scheduled surgery as well as in cadaveric porcine eyes. MIOCT imaging of human subjects was performed in healthy normal volunteers and intraoperatively at a normal pause immediately following surgical manipulations, under an Institutional Review Board-approved protocol, with informed consent from all subjects. Video MIOCT imaging of live surgical manipulations was performed in cadaveric porcine eyes by carefully aligning B-scans with instrument orientation and movement. Inverted imaging was performed by lengthening of the reference arm to a position beyond the choroid. Unprocessed MIOCT imaging was successfully obtained in healthy human volunteers and in human patients undergoing surgery, with visualization of post-surgical changes in unprocessed single B-scans. Real-time, unprocessed MIOCT video imaging was successfully obtained in cadaveric porcine eyes during brushing of the retina with the Tano scraper, peeling of superficial retinal tissue with intraocular forceps, and separation of the posterior hyaloid face. Real-time inverted imaging enabled imaging without complex conjugate artifacts. MIOCT is capable of unprocessed imaging of the macula in human patients undergoing surgery and of unprocessed, real-time, video imaging of surgical maneuvers in model eyes. These capabilities represent an important step towards development of MIOCT for efficient, real-time imaging of manipulations during human surgery.
Eye-Target Synchrony and Attention
NASA Astrophysics Data System (ADS)
Contreras, R.; Kolster, R.; Basu, S.; Voss, H. U.; Ghajar, J.; Suh, M.; Bahar, S.
2007-03-01
Eye-target synchrony is critical during smooth pursuit. We apply stochastic phase synchronization to human pursuit of a moving target, in both normal and mild traumatic brain injured (TBI) subjects. Smooth pursuit utilizes the same neural networks used by attention. To test whether smooth pursuit is modulated by attention, subjects tracked a target while loaded with tasks involving working memory. Preliminary results suggest that additional cognitive load increases normal subjects' performance, while the effect is reversed in TBI patients. We correlate these results with eye-target synchrony. Additionally, we correlate eye-target synchrony with frequency of target motion, and discuss how the range of frequencies for optimal synchrony depends on the shift from attentional to automatic-response time scales. Synchrony deficits in TBI patients can be correlated with specific regions of brain damage imaged with diffusion tensor imaging (DTI).
Expression of classical components of the renin-angiotensin system in the human eye.
White, Andrew J R; Cheruvu, Sarat C; Sarris, Maria; Liyanage, Surabhi S; Lumbers, Eugenie; Chui, Jeanie; Wakefield, Denis; McCluskey, Peter J
2015-03-01
The purpose of this study was to determine the relative expression of clinically-relevant components of the renin-angiotensin system (RAS) in the adult human eye. We obtained 14 post-mortem enucleated human eyes from patients whom had no history of inflammatory ocular disease nor pre-mortem ocular infection. We determined the gene expression for prorenin, renin, prorenin receptor, angiotensin-converting enzyme, angiotensinogen and angiotensin II Type 1 receptor, on tissue sections and in cultured human primary retinal pigment epithelial and iris pigment epithelial (RPE/IPE) cell lines, using both qualitative and quantitative reverse transcription polymerase chain reaction (RT-PCR). Protein expression was studied using indirect immunofluorescence (IF). Almost all components of the classical RAS were found at high levels, at both the transcript and protein level, in the eyes' uvea and retina; and at lower levels in the cornea, conjunctiva and sclera. There was a much lower level of expression in the reference cultured RPE/IPE cells lines. This study describes the distribution of RAS in the normal adult human eye and demonstrates the existence of an independent ocular RAS, with uveal and retinal tissues showing the highest expression of RAS components. These preliminary findings provide scope for examination of additional components of this system in the human eye, as well as possible differential expression under pathological conditions. © The Author(s) 2014.
In vivo confocal microscopy of human cornea covered with human amniotic membrane.
Mimura, Tatsuya; Yamagami, Satoru; Usui, Tomohiko; Honda, Norihiko; Araki, Fumiyuki; Amano, Shiro
2008-01-01
Amniotic membrane transplantation has been widely performed to reconstruct the surface of the eye and treat chemical burns or epithelial defects. However, we have difficulty observing the cornea through the opaque transplanted amniotic membrane by slit-lamp biomicroscopy. We investigated the use of confocal microscopy for observation of human corneas covered with amniotic membrane. Human amniotic membrane was placed onto the normal corneas of five volunteers aged 22-24 years. Then, all layers of the covered corneas were observed by in vivo confocal microscopy. Confocal microscopy displayed the epithelium, basement membrane, and stroma of the amniotic membrane. It also displayed the corneal epithelium. Furthermore, corneal stromal keratocytes and the corneal endothelium were clearly observed through the amniotic membrane by confocal microscopy. We demonstrated that in vivo confocal microscopy enabled us to observe all layers of corneas covered with amniotic membrane in normal human eyes. Our findings suggest that confocal microscopy may have advantages for clinical examination of the ocular surface, including all layers of the cornea.
OCT angiography by absolute intensity difference applied to normal and diseased human retinas
Ruminski, Daniel; Sikorski, Bartosz L.; Bukowska, Danuta; Szkulmowski, Maciej; Krawiec, Krzysztof; Malukiewicz, Grazyna; Bieganowski, Lech; Wojtkowski, Maciej
2015-01-01
We compare four optical coherence tomography techniques for noninvasive visualization of microcapillary network in the human retina and murine cortex. We perform phantom studies to investigate contrast-to-noise ratio for angiographic images obtained with each of the algorithm. We show that the computationally simplest absolute intensity difference angiographic OCT algorithm that bases only on two cross-sectional intensity images may be successfully used in clinical study of healthy eyes and eyes with diabetic maculopathy and branch retinal vein occlusion. PMID:26309740
ERIC Educational Resources Information Center
Science Teacher, 2005
2005-01-01
Two science questions are answered: (1) How can someone have one brown eye and one blue eye?, and (2) Why are magnets attracted to some metals, but not all metals? It is very rare that a human will have two irises of different colors. This condition, heterochromia, can be a normal variant or the result of an ocular disease. Heterochromia can…
Mathis, Ute; Ziemssen, Focke; Schaeffel, Frank
2014-10-01
Vascular endothelial growth factor (VEGF) is a dimeric glycoprotein which is responsible for neovascularization and fenestrations of the choriocapillaris. In neovascular maculopathies secondary to age-related degeneration (nAMD) or pathologic myopia (PM-CNV), its inhibition by humanized antibodies is currently the most successful therapy. The choroid has an important role in maintaining retinal health and its thickness declines with age and with myopia. Since choroidal thickness depends on its perfusion rate, one would expect that anti-VEGF agents can also change choroidal thickness. We have tested the hypothesis in the chicken model, using a humanized antibody, Bevacizumab, and also studied the distribution of VEGF-A in the chicken fundal layers by immunohistochemical techniques. Even though it was raised against human VEGF, Bevacizumab had several long lasting effects in the chicken eye (1) after a single unilateral intravitreal injection of 0.5 mg, it partially suppressed the development of deprivation myopia, similarly in both eyes, (2) it completely suppressed choroidal thickening that normally occurs when eyes recover from induced myopia over a time period of about 10 days, (3) it had little effect on the choroidal thickness in eyes that had normal visual experience, (4) VEGF-A was absent in sclera, but highly expressed in the walls of choroidal blood vessels and presumed nerve fiber bundles, as well as in retinal photoreceptors and cells of the inner and outer nuclear layer. One day after the injection of Bevacizumab, the immunoreactivity against VEGF-A had largely disappeared. In conclusion, Bevacizumab is similary effective in human and chicken tissue, has similar time constants (few days), has almost symmetrical effects on myopia in both eyes even after monocular application, and fully suppresses choroidal thickening that normally occurs during recovery from deprivation myopia. The mechanisms by which Bevacizumab acts on the choroidal thickness are perhaps most interesting, both to better understand the role of the choroid in myopia development but also to clarify its potential side effects during nAMD and PM-CNV treatment in the clinics. Copyright © 2014 Elsevier Ltd. All rights reserved.
Zhang, Zhen Huan; Pan, Meng Xin; Cai, Jia Tong; Weiland, James D; Chen, Kinon
2018-03-26
The purpose of this study is to measure, characterize, and compare the viscoelastic properties of the posterior eye of advanced dry age-related macular degeneration (AMD) patients, age-matched normal subjects, and pigs (3 groups). Ten horizontal and ten vertical strips of the macula retina and the underneath choroid and sclera were obtained for each group, respectively. They were examined by incremental stress-relaxation cycles in body-temperature saline. Mechanical response was characterized by the quasi-linear viscoelastic model. All the tissues were shown to be nonlinear viscoelastic. Stiffening and isotropization, increased relaxation, and softening and isotropization were found in AMD retina, choroid, and sclera, respectively, which are the mechanical features of the atherosclerotic process. The patients' medical records were in accordance with epidemiological studies indicating a relationship between the advanced AMD and atherosclerotic vascular disease (ASVD). Moreover, many differences were found between the viscoelastic properties of porcine and normal human retina, choroid, and sclera. The results suggest that AMD is associated with ASVD through a mechanism involving abnormal retinal, choroidal, and scleral mechanics similar to those seen in the atherosclerotic process. Moreover, researchers should be aware of mechanical differences when using porcine posterior eyes as a substitute for human posterior eyes. © 2018 Wiley Periodicals, Inc. J Biomed Mater Res Part A, 2018. © 2018 Wiley Periodicals, Inc.
Li, Bing; Sheng, Minjie; Xie, Liqi; Liu, Feng; Yan, Guoquan; Wang, Weifang; Lin, Anjuan; Zhao, Fei; Chen, Yihui
2014-01-09
Diabetes mellitus has been shown to be associated with and complicated by dry eye syndrome. We sought to examine and compare the tear film proteome of type 2 diabetic patients with or without dry eye syndrome and normal subjects using two-dimensional nano-liquid chromatography coupled with tandem mass spectrometry (MS)-based proteomics. Tears were collected from eight type 2 diabetes patients with dry eye syndrome, eight type 2 diabetes patients without dry eye syndrome, and eight normal subjects. Tear breakup time (BUT) was determined, and tear proteins were prepared and analyzed using two-dimensional strong cation-exchange/reversed-phase nano-scale liquid chromatography MS. All MS/MS spectra were identified by using SEQUEST against the human International Protein Index (IPI) database and the relative abundance of individual proteins was assessed by spectral counting. Tear BUT was significantly lower in patients with diabetes and dry eye syndrome than in patients with diabetes only and normal subjects. Analysis of spectral counts of tear proteins showed that, compared to healthy controls, patients with diabetes and dry eye syndrome had increased expression of apoptosis-related proteins, like annexin A1, and immunity- and inflammation-related proteins, including neutrophil elastase 2 and clusterin, and glycometabolism-related proteins, like apolipoprotein A-II. Dry eye syndrome in diabetic patients is associated with aberrant expression of tear proteins, and the findings could lead to identification of novel pathways for therapeutic targeting and new diagnostic markers.
Hann, Cheryl R.; Bentley, Michael D.; Vercnocke, Andrew; Ritman, Erik L.; Fautsch, Michael P.
2011-01-01
The site of outflow resistance leading to elevated intraocular pressure in primary open angle glaucoma is believed to be located in the region of Schlemm’s canal inner wall endothelium, its basement membrane and the adjacent juxtacanalicular tissue. Evidence also suggests collector channels and intrascleral vessels may have a role in intraocular pressure in both normal and glaucoma eyes. Traditional imaging modalities limit the ability to view both proximal and distal portions of the trabecular outflow pathway as a single unit. In this study, we examined the effectiveness of three-dimensional micro-computed tomography (3D micro-CT) as a potential method to view the trabecular outflow pathway. Two normal human eyes were used: one immersion fixed in 4% paraformaldehyde, and one with anterior chamber perfusion at 10 mmHg followed by perfusion fixation in 4% paraformaldehyde/2% glutaraldehyde. Both eyes were postfixed in 1% osmium tetroxide, and scanned with 3D micro-CT at 2 µm or 5 µm voxel resolution. In the immersion fixed eye, 24 collector channels were identified with an average orifice size of 27.5 ± 5 µm. In comparison, the perfusion fixed eye had 29 collector channels with a mean orifice size of 40.5 ± 13 µm. Collector channels were not evenly dispersed around the circumference of the eye. There was no significant difference in the length of Schlemm’s canal in the immersed versus the perfused eye (33.2 versus 35.1 mm). Structures, locations and size measurements identified by 3D micro-CT were confirmed by correlative light microscopy. These findings confirm 3D micro-CT can be used effectively for the non-invasive examination of the trabecular meshwork, Schlemm’s canal, collector channels and intrascleral vasculature that comprise the distal outflow pathway. This imaging modality will be useful for noninvasive study of the role of the trabecular outflow pathway as a whole unit. PMID:21187085
An optomechanical model eye for ophthalmological refractive studies.
Arianpour, Ashkan; Tremblay, Eric J; Stamenov, Igor; Ford, Joseph E; Schanzlin, David J; Lo, Yuhwa
2013-02-01
To create an accurate, low-cost optomechanical model eye for investigation of refractive errors in clinical and basic research studies. An optomechanical fluid-filled eye model with dimensions consistent with the human eye was designed and fabricated. Optical simulations were performed on the optomechanical eye model, and the quantified resolution and refractive errors were compared with the widely used Navarro eye model using the ray-tracing software ZEMAX (Radiant Zemax, Redmond, WA). The resolution of the physical optomechanical eye model was then quantified with a complementary metal-oxide semiconductor imager using the image resolution software SFR Plus (Imatest, Boulder, CO). Refractive, manufacturing, and assembling errors were also assessed. A refractive intraocular lens (IOL) and a diffractive IOL were added to the optomechanical eye model for tests and analyses of a 1951 U.S. Air Force target chart. Resolution and aberrations of the optomechanical eye model and the Navarro eye model were qualitatively similar in ZEMAX simulations. Experimental testing found that the optomechanical eye model reproduced properties pertinent to human eyes, including resolution better than 20/20 visual acuity and a decrease in resolution as the field of view increased in size. The IOLs were also integrated into the optomechanical eye model to image objects at distances of 15, 10, and 3 feet, and they indicated a resolution of 22.8 cycles per degree at 15 feet. A life-sized optomechanical eye model with the flexibility to be patient-specific was designed and constructed. The model had the resolution of a healthy human eye and recreated normal refractive errors. This model may be useful in the evaluation of IOLs for cataract surgery. Copyright 2013, SLACK Incorporated.
Eyes open versus eyes closed - Effect on human rotational responses
NASA Technical Reports Server (NTRS)
Wall, Conrad, III; Furman, Joseph M. R.
1989-01-01
The effect of eyelid closure on the response to rotational vestibular stimulation was assessed by evaluating 16 normal human subjects with both earth vertical axis (EVA) and earth horizontal axis (EHA) yaw rotations with either eyes closed (EC) or eyes open in the dark (EOD). Results indicated that for EVA rotation, the subjects' responses were of larger magnitude and less variable with EOD than with EC. However, for EHA rotation, responses were of larger magnitude and equally variable with EC as compared to EOD. Data also indicated that the quality of the EHA response with EC was altered because eyelid closure influenced the amount of periodic gaze. It is concluded that eyelid closure has an effect upon both canalocular and otolithocular reflexes and it is suggested that both EVA and EHA rotational testing be performed with EOD rather than with EC.
Lutein and its oxidized forms in eye structures throughout prenatal human development.
Panova, Ina G; Yakovleva, Marina A; Tatikolov, Alexander S; Kononikhin, A S; Feldman, Tatiana B; Poltavtseva, Rimma A; Nikolaev, E N; Sukhikh, Gennady T; Ostrovsky, Mikhail A
2017-07-01
The presence of carotenoids in the vitreous body, retina, lens, retinal pigment epithelium together with choroid (hereinafter RPE), and ciliary body and iris together with choroidal stroma (hereinafter CBI) was studied throughout the second trimester of prenatal development of the human eye. It has been found that the vitreous body, retina, and RPE contain lutein and its oxidized forms. Zeaxanthin was not found in the tissues studied. The presence of lutein in the vitreous body is transient and no longer detected after 28 weeks of gestation. Lutein was not detected in the lens and CBI, but its oxidized forms were found. The presence of carotenoids in different tissues of the eye in the course of normal eye development and the antioxidant role of carotenoids are discussed. Copyright © 2017 Elsevier Ltd. All rights reserved.
Elemental composition of some essential cations in human ocular tissue
DOE Office of Scientific and Technical Information (OSTI.GOV)
Panessa-Warren, B.J.; Kraner, H.W.; Warren, J.B.
1983-01-01
To obtain data on the baseline elemental content in normal adult sensory retina, RPE and iris, normal non-diabetic eyes were analyzed and these results were used for comparison to similarly prepared samples from diabetic donor eyes. To determine if the concentrations of the cations, Ca, Ba and Zn were altered by the age, alimentation and exposure to light of the donor, tissue from children (from 25 weeks gestation to 8-1/2 years old) was also analyzed by x-ray fluorescence spectroscopy, proton induced x-ray emission spectroscopy, and light and electron (scanning and transmission) microscopy.
NASA Astrophysics Data System (ADS)
Putnam, Nicole Marie
In order to study the limits of spatial vision in normal human subjects, it is important to look at and near the fovea. The fovea is the specialized part of the retina, the light-sensitive multi-layered neural tissue that lines the inner surface of the human eye, where the cone photoreceptors are smallest (approximately 2.5 microns or 0.5 arcmin) and cone density reaches a peak. In addition, there is a 1:1 mapping from the photoreceptors to the brain in this central region of the retina. As a result, the best spatial sampling is achieved in the fovea and it is the retinal location used for acuity and spatial vision tasks. However, vision is typically limited by the blur induced by the normal optics of the eye and clinical tests of foveal vision and foveal imaging are both limited due to the blur. As a result, it is unclear what the perceptual benefit of extremely high cone density is. Cutting-edge imaging technology, specifically Adaptive Optics Scanning Laser Ophthalmoscopy (AOSLO), can be utilized to remove this blur, zoom in, and as a result visualize individual cone photoreceptors throughout the central fovea. This imaging combined with simultaneous image stabilization and targeted stimulus delivery expands our understanding of both the anatomical structure of the fovea on a microscopic scale and the placement of stimuli within this retinal area during visual tasks. The final step is to investigate the role of temporal variables in spatial vision tasks since the eye is in constant motion even during steady fixation. In order to learn more about the fovea, it becomes important to study the effect of this motion on spatial vision tasks. This dissertation steps through many of these considerations, starting with a model of the foveal cone mosaic imaged with AOSLO. We then use this high resolution imaging to compare anatomical and functional markers of the center of the normal human fovea. Finally, we investigate the role of natural and manipulated fixational eye movements in foveal vision, specifically looking at a motion detection task, contrast sensitivity, and image fading.
Eye Dominance Predicts fMRI Signals in Human Retinotopic Cortex
Mendola, Janine D.; Conner, Ian P.
2009-01-01
There have been many attempts to define eye dominance in normal subjects, but limited consensus exists, and relevant physiological data is scarce. In this study, we consider two different behavioral methods for assignment of eye dominance, and how well they predict fMRI signals evoked by monocular stimulation. Sighting eye dominance was assessed with two standard tests, the Porta Test, and a ‘hole in hand’ variation of the Miles Test. Acuity dominance was tested with a standard eye chart and with a computerized test of grating acuity. We found limited agreement between the sighting and acuity methods for assigning dominance in our individual subjects. We then compared the fMRI response generated by dominant eye stimulation to that generated by non-dominant eye, according to both methods, in 7 normal subjects. The stimulus consisted of a high contrast hemifield stimulus alternating with no stimulus in a blocked paradigm. In separate scans, we used standard techniques to label the borders of visual areas V1, V2, V3, VP, V4, V3A, and MT. These regions of interest (ROIs) were used to analyze each visual area separately. We found that percent change in fMRI BOLD signal was stronger for the dominant eye as defined by the acuity method, and this effect was significant for areas located in the ventral occipital territory (V1v, V2v, VP, V4). In contrast, assigning dominance based on sighting produced no significant interocular BOLD differences. We conclude that interocular BOLD differences in normal subjects exist, and may be predicted by acuity measures. PMID:17194544
Kobashi, Hidenaga; Kamiya, Kazutaka; Yanome, Kyohei; Igarashi, Akihito; Shimizu, Kimiya
2013-01-01
To assess the longitudinal changes in optical quality including intraocular scattering in normal eyes and eyes with short tear breakup time (TBUT). We prospectively examined twenty eyes of 20 healthy subjects, and age-matched twenty eyes of 20 short TBUT subjects. The modulation transfer function (MTF) cutoff frequency, the Strehl ratio, and the objective scattering index (OSI) were quantitatively assessed using an Optical Quality Analysis System. We investigated the changes in these variables measured consecutively at the initial examination, 5, and 10 seconds without blinking. We also compared these variables in eyes with short TBUT with those in normal eyes. No significant differences in the MTF cutoff frequency, Strehl ratio, or OSI were detected over a 10-second period in normal eyes. These variables also became significantly degraded even over a 5-second period in eyes with short TBUT (p<0.01). We found significant differences in these variables at 5 and 10 seconds (p<0.05), but none immediately after the blink between normal and short TBUT eyes. Optical quality including intraocular scattering deteriorated significantly with time in eyes with short TBUT, whereas we found significant differences over a 10-second period in normal eyes. Eyes with short TBUT showed greater deterioration in optical quality after the blink than normal eyes. The longitudinal assessment of optical quality may be effective in distinguishing eyes with short TBUT from normal eyes.
The case from animal studies for balanced binocular treatment strategies for human amblyopia.
Mitchell, Donald E; Duffy, Kevin R
2014-03-01
Although amblyopia typically manifests itself as a monocular condition, its origin has long been linked to unbalanced neural signals from the two eyes during early postnatal development, a view confirmed by studies conducted on animal models in the last 50 years. Despite recognition of its binocular origin, treatment of amblyopia continues to be dominated by a period of patching of the non-amblyopic eye that necessarily hinders binocular co-operation. This review summarizes evidence from three lines of investigation conducted on an animal model of deprivation amblyopia to support the thesis that treatment of amblyopia should instead focus upon procedures that promote and enhance binocular co-operation. First, experiments with mixed daily visual experience in which episodes of abnormal visual input were pitted against normal binocular exposure revealed that short exposures of the latter offset much longer periods of abnormal input to allow normal development of visual acuity in both eyes. Second, experiments on the use of part-time patching revealed that purposeful introduction of episodes of binocular vision each day could be very beneficial. Periods of binocular exposure that represented 30-50% of the daily visual exposure included with daily occlusion of the non-amblyopic could allow recovery of normal vision in the amblyopic eye. Third, very recent experiments demonstrate that a short 10 day period of total darkness can promote very fast and complete recovery of visual acuity in the amblyopic eye of kittens and may represent an example of a class of artificial environments that have similar beneficial effects. Finally, an approach is described to allow timing of events in kitten and human visual system development to be scaled to optimize the ages for therapeutic interventions. © 2014 The Authors Ophthalmic & Physiological Optics © 2014 The College of Optometrists.
Coudrillier, Baptiste; Pijanka, Jacek K.; Jefferys, Joan L.; Goel, Adhiraj; Quigley, Harry A.; Boote, Craig; Nguyen, Thao D.
2015-01-01
Objective The biomechanical behavior of the sclera determines the level of mechanical insult from intraocular pressure to the axons and tissues of the optic nerve head, as is of interest in glaucoma. In this study, we measure the collagen fiber structure and the strain response, and estimate the material properties of glaucomatous and normal human donor scleras. Methods Twenty-two posterior scleras from normal and diagnosed glaucoma donors were obtained from an eyebank. Optic nerve cross-sections were graded to determine the presence of axon loss. The specimens were subjected to pressure-controlled inflation testing. Full-field displacement maps were measured by digital image correlation (DIC) and spatially differentiated to compute surface strains. Maps of the collagen fiber structure across the posterior sclera of each inflated specimen were obtained using synchrotron wide-angle X-ray scattering (WAXS). Finite element (FE) models of the posterior scleras, incorporating a specimen-specific representation of the collagen structure, were constructed from the DIC-measured geometry. An inverse finite element analysis was developed to estimate the stiffness of the collagen fiber and inter-fiber matrix. Results The differences between glaucoma and non-glaucoma eyes were small in magnitude. Sectorial variations of degree of fiber alignment and peripapillary scleral strain significantly differed between normal and diagnosed glaucoma specimens. Meridional strains were on average larger in diagnosed glaucoma eyes compared with normal specimens. Non-glaucoma specimens had on average the lowest matrix and fiber stiffness, followed by undamaged glaucoma eyes, and damaged glaucoma eyes but the differences in stiffness were not significant. Conclusion The observed biomechanical and microstructural changes could be the result of tissue remodeling occuring in glaucoma and are likely to alter the mechanical environment of the optic nerve head and contribute to axonal damage. PMID:26161963
Clavagnier, Simon; Dumoulin, Serge O; Hess, Robert F
2015-11-04
The neural basis of amblyopia is a matter of debate. The following possibilities have been suggested: loss of foveal cells, reduced cortical magnification, loss of spatial resolution of foveal cells, and topographical disarray in the cellular map. To resolve this we undertook a population receptive field (pRF) functional magnetic resonance imaging analysis in the central field in humans with moderate-to-severe amblyopia. We measured the relationship between averaged pRF size and retinal eccentricity in retinotopic visual areas. Results showed that cortical magnification is normal in the foveal field of strabismic amblyopes. However, the pRF sizes are enlarged for the amblyopic eye. We speculate that the pRF enlargement reflects loss of cellular resolution or an increased cellular positional disarray within the representation of the amblyopic eye. The neural basis of amblyopia, a visual deficit affecting 3% of the human population, remains a matter of debate. We undertook the first population receptive field functional magnetic resonance imaging analysis in participants with amblyopia and compared the projections from the amblyopic and fellow normal eye in the visual cortex. The projection from the amblyopic eye was found to have a normal cortical magnification factor, enlarged population receptive field sizes, and topographic disorganization in all early visual areas. This is consistent with an explanation of amblyopia as an immature system with a normal complement of cells whose spatial resolution is reduced and whose topographical map is disordered. This bears upon a number of competing theories for the psychophysical defect and affects future treatment therapies. Copyright © 2015 the authors 0270-6474/15/3514740-16$15.00/0.
Zheng, Xiaofen; De Paiva, Cintia S; Rao, Kavita; Li, De-Quan; Farley, William J; Stern, Michael; Pflugfelder, Stephen C
2010-09-01
To develop a new bioassay method using human lung epithelial cells (CCL-185) to assess activity of transforming growth factor beta (TGF-beta) in human tear fluid from normal subjects and patients with dry eye. Two epithelial cell lines, mink lung cells (CCL-64) and human lung cells (CCL-185), were compared to detect the active form of TGF-beta by BrdU incorporation (quantitation of cell DNA synthesis) and WST assay (metabolic activity of viable cells). The effect of TGF-beta on the growth of CCL-185 cells was observed microscopically. Human tears from normal control subjects and patients with dry eye (DE) with and without Sjögren syndrome were evaluated for TGF-beta concentration by Luminex microbead assay, and TGF-beta activity by the CCL-185 cell growth inhibition bioassay. The metabolic activity of viable CCL-185 cells, measured by WST, was shown to be proportional to the TGF-beta1 concentration (R = 0.919) and confirmed by BrdU assay (R = 0.969). Compared with CCL-185, metabolic activity of viable cells and DNA synthesis, measured by WST and BrdU incorporation assays, were shown to be less proportional to the TGF-beta1 concentration in the CCL-64 line (R = 0.42 and 0.17, respectively). Coincubation with human anti-TGF-beta1 antibody (MAB-240) yielded a dose-dependent inhibition of TGF-beta1 (0.3 ng/mL) activity. CCL-185 cell growth observed microscopically was noted to decrease in response to increasing TGF-beta1 concentrations. Levels of immuodetectable TGF-beta1 and TGF-beta2 were similar in normal and DE tears. TGF-beta bioactivity in DE human tears measured by the CCL-185 cells assay was found to be higher (9777.5 +/- 10481.9 pg/mL) than those in normal controls (4129.3 +/- 1342.9 pg/mL) (P < 0.05). Among patients with DE, TGF-beta bioactivity was highest in those with Sjögren syndrome. Approximately, 79.1% of TGF-beta in DE tears and 37.6% TGF-beta in normal tears were found to be biologically active. The CCL-185 cell assay was found to be a suitable tool for assessing TGF-beta activity in human tears. Tear TGF-beta bioactivity increases in DE, particularly in Sjögren syndrome, where elevated levels of TGF-beta1 transcripts in the conjunctival epithelium have been previously detected.
Defining the Human Macula Transcriptome and Candidate Retinal Disease Genes UsingEyeSAGE
Rickman, Catherine Bowes; Ebright, Jessica N.; Zavodni, Zachary J.; Yu, Ling; Wang, Tianyuan; Daiger, Stephen P.; Wistow, Graeme; Boon, Kathy; Hauser, Michael A.
2009-01-01
Purpose To develop large-scale, high-throughput annotation of the human macula transcriptome and to identify and prioritize candidate genes for inherited retinal dystrophies, based on ocular-expression profiles using serial analysis of gene expression (SAGE). Methods Two human retina and two retinal pigment epithelium (RPE)/choroid SAGE libraries made from matched macula or midperipheral retina and adjacent RPE/choroid of morphologically normal 28- to 66-year-old donors and a human central retina longSAGE library made from 41- to 66-year-old donors were generated. Their transcription profiles were entered into a relational database, EyeSAGE, including microarray expression profiles of retina and publicly available normal human tissue SAGE libraries. EyeSAGE was used to identify retina- and RPE-specific and -associated genes, and candidate genes for retina and RPE disease loci. Differential and/or cell-type specific expression was validated by quantitative and single-cell RT-PCR. Results Cone photoreceptor-associated gene expression was elevated in the macula transcription profiles. Analysis of the longSAGE retina tags enhanced tag-to-gene mapping and revealed alternatively spliced genes. Analysis of candidate gene expression tables for the identified Bardet-Biedl syndrome disease gene (BBS5) in the BBS5 disease region table yielded BBS5 as the top candidate. Compelling candidates for inherited retina diseases were identified. Conclusions The EyeSAGE database, combining three different gene-profiling platforms including the authors’ multidonor-derived retina/RPE SAGE libraries and existing single-donor retina/RPE libraries, is a powerful resource for definition of the retina and RPE transcriptomes. It can be used to identify retina-specific genes, including alternatively spliced transcripts and to prioritize candidate genes within mapped retinal disease regions. PMID:16723438
Defining the human macula transcriptome and candidate retinal disease genes using EyeSAGE.
Bowes Rickman, Catherine; Ebright, Jessica N; Zavodni, Zachary J; Yu, Ling; Wang, Tianyuan; Daiger, Stephen P; Wistow, Graeme; Boon, Kathy; Hauser, Michael A
2006-06-01
To develop large-scale, high-throughput annotation of the human macula transcriptome and to identify and prioritize candidate genes for inherited retinal dystrophies, based on ocular-expression profiles using serial analysis of gene expression (SAGE). Two human retina and two retinal pigment epithelium (RPE)/choroid SAGE libraries made from matched macula or midperipheral retina and adjacent RPE/choroid of morphologically normal 28- to 66-year-old donors and a human central retina longSAGE library made from 41- to 66-year-old donors were generated. Their transcription profiles were entered into a relational database, EyeSAGE, including microarray expression profiles of retina and publicly available normal human tissue SAGE libraries. EyeSAGE was used to identify retina- and RPE-specific and -associated genes, and candidate genes for retina and RPE disease loci. Differential and/or cell-type specific expression was validated by quantitative and single-cell RT-PCR. Cone photoreceptor-associated gene expression was elevated in the macula transcription profiles. Analysis of the longSAGE retina tags enhanced tag-to-gene mapping and revealed alternatively spliced genes. Analysis of candidate gene expression tables for the identified Bardet-Biedl syndrome disease gene (BBS5) in the BBS5 disease region table yielded BBS5 as the top candidate. Compelling candidates for inherited retina diseases were identified. The EyeSAGE database, combining three different gene-profiling platforms including the authors' multidonor-derived retina/RPE SAGE libraries and existing single-donor retina/RPE libraries, is a powerful resource for definition of the retina and RPE transcriptomes. It can be used to identify retina-specific genes, including alternatively spliced transcripts and to prioritize candidate genes within mapped retinal disease regions.
Eye gazing direction inspection based on image processing technique
NASA Astrophysics Data System (ADS)
Hao, Qun; Song, Yong
2005-02-01
According to the research result in neural biology, human eyes can obtain high resolution only at the center of view of field. In the research of Virtual Reality helmet, we design to detect the gazing direction of human eyes in real time and feed it back to the control system to improve the resolution of the graph at the center of field of view. In the case of current display instruments, this method can both give attention to the view field of virtual scene and resolution, and improve the immersion of virtual system greatly. Therefore, detecting the gazing direction of human eyes rapidly and exactly is the basis of realizing the design scheme of this novel VR helmet. In this paper, the conventional method of gazing direction detection that based on Purklinje spot is introduced firstly. In order to overcome the disadvantage of the method based on Purklinje spot, this paper proposed a method based on image processing to realize the detection and determination of the gazing direction. The locations of pupils and shapes of eye sockets change with the gazing directions. With the aid of these changes, analyzing the images of eyes captured by the cameras, gazing direction of human eyes can be determined finally. In this paper, experiments have been done to validate the efficiency of this method by analyzing the images. The algorithm can carry out the detection of gazing direction base on normal eye image directly, and it eliminates the need of special hardware. Experiment results show that the method is easy to implement and have high precision.
Real-Time Confocal Imaging Of The Living Eye
NASA Astrophysics Data System (ADS)
Jester, James V.; Cavanagh, H. Dwight; Essepian, John; Shields, William J.; Lemp, Michael A.
1989-12-01
In 1986, we adapted the Tandem Scanning Reflected Light Microscope of Petran and Hadraysky to permit non-invasive, confocal imaging of the living eye in real-time. We were first to obtain stable, confocal optical sections in vivo, from human and animal eyes. Using confocal imaging systems we have now studied living, normal volunteers, rabbits, cats and primates sequentially, non-invasively, and in real-time. The continued development of real-time confocal imaging systems will unlock the door to a new field of cell biology involving for the first time the study of dynamic cellular processes in living organ systems. Towards this end we have concentrated our initial studies on three areas (1) evaluation of confocal microscope systems for real-time image acquisition, (2) studies of the living normal cornea (epithelium, stroma, endothelium) in human and other species; and (3) sequential wound-healing responses in the cornea in single animals to lamellar-keratectomy injury (cellular migration, inflammation, scarring). We believe that this instrument represents an important, new paradigm for research in cell biology and pathology and that it will fundamentally alter all experimental and clinical approaches in future years.
Abnormal tuning of saccade-related cells in pontine reticular formation of strabismic monkeys.
Walton, Mark M G; Mustari, Michael J
2015-08-01
Strabismus is a common disorder, characterized by a chronic misalignment of the eyes and numerous visual and oculomotor abnormalities. For example, saccades are often highly disconjugate. For humans with pattern strabismus, the horizontal and vertical disconjugacies vary with eye position. In monkeys, manipulations that disturb binocular vision during the first several weeks of life result in a chronic strabismus with characteristics that closely match those in human patients. Early onset strabismus is associated with altered binocular sensitivity of neurons in visual cortex. Here we test the hypothesis that brain stem circuits specific to saccadic eye movements are abnormal. We targeted the pontine paramedian reticular formation, a structure that directly projects to the ipsilateral abducens nucleus. In normal animals, neurons in this structure are characterized by a high-frequency burst of spikes associated with ipsiversive saccades. We recorded single-unit activity from 84 neurons from four monkeys (two normal, one exotrope, and one esotrope), while they made saccades to a visual target on a tangent screen. All 24 neurons recorded from the normal animals had preferred directions within 30° of pure horizontal. For the strabismic animals, the distribution of preferred directions was normal on one side of the brain, but highly variable on the other. In fact, 12/60 neurons recorded from the strabismic animals preferred vertical saccades. Many also had unusually weak or strong bursts. These data suggest that the loss of corresponding binocular vision during infancy impairs the development of normal tuning characteristics for saccade-related neurons in brain stem. Copyright © 2015 the American Physiological Society.
Gasmelseed, Akram; Yunus, Jasmy
2014-01-01
The interaction of a dipole antenna with a human eye model in the presence of a metamaterial is investigated in this paper. The finite difference time domain (FDTD) method with convolutional perfectly matched layer (CPML) formulation have been used. A three-dimensional anatomical model of the human eye with resolution of 1.25 mm × 1.25 mm × 1.25 mm was used in this study. The dipole antenna was driven by modulated Gaussian pulse and the numerical study is performed with dipole operating at 900 MHz. The analysis has been done by varying the size and value of electric permittivity of the metamaterial. By normalizing the peak SAR (1 g and 10 g) to 1 W for all examined cases, we observed how the SAR values are not affected by the different permittivity values with the size of the metamaterial kept fixed. Copyright © 2013 Elsevier Ltd. All rights reserved.
The APO*E3-Leiden mouse as an animal model for basal laminar deposit
Kliffen, M.; Lutgens, E.; Daemen, M.; de Muinck, E. D; Mooy, C.; de Jong, P. T V M
2000-01-01
AIM—To investigate the APO*E3-Leiden mouse as an animal model for age related maculopathy (ARM) related extracellular deposits. METHODS—Eyes were obtained from APO*E3-Leiden transgenic mice on a high fat/cholesterol (HFC) diet (n=12) or on a normal mouse chow (n=6), for 9 months. As controls, eyes were collected from APO-E knockout mice on the same diets. From each mouse one eye was processed for microscopic evaluation and immunohistochemistry with a polyclonal antibody directed against human apo-E. Electron microscopy was also performed. RESULTS—All 12 eyes of the APO*E3-Leiden mice on an HFC diet contained basal laminar deposit (BLD; class 1 to class 3), whereas two of six APO*E3-Leiden mice on normal chow showed BLD class 1. The ultrastructural aspects of this BLD were comparable with those seen in early BLD in humans, and BLD showed immunoreaction with anti-human-apo-E antibodies. No BLD was found in any of the control mice. Drusen were not detected in any of the mice. CONCLUSION—These results indicate that APO*E3-Leiden mice can be used as animal model for the pathogenesis of BLD, and that a HFC diet enhances the accumulation of this deposit. Furthermore, this study supports the previously suggested involvement of dysfunctional apo-E in the accumulation of extracellular deposits in ARM. PMID:11090485
Foveal shape and structure in a normal population.
Tick, Sarah; Rossant, Florence; Ghorbel, Itebeddine; Gaudric, Alain; Sahel, José-Alain; Chaumet-Riffaud, Philippe; Paques, Michel
2011-07-29
The shape of the human fovea presents important but still poorly characterized variations. In this study, the variability of the shape and structure of normal foveae were examined. In a group of 110 eyes of 57 healthy adults, the shape and structure of the fovea were analyzed by automated segmentation of retinal layer on high-resolution optical coherence tomography scans. In an additional group of 10 normal eyes of 10 patients undergoing fluorescein angiography, the size of the foveal avascular zone (FAZ) was correlated to foveal shape. From the thickest to the thinnest fovea, there was a structural continuum ranging from a shallow pit with continuity of the inner nuclear layer (INL) over the center (seven eyes; 6.7%), to a complete separation of inner layers overlying a flat and thinner central outer nuclear layer (ONL; eight eyes; 7.3%). Central foveal thickness correlated inversely to the degree of inner layer separation and to the surface of the FAZ. Foveal structure strongly correlates with its neurovascular organization. The findings support a developmental model in which the size of the FAZ determines the extent of centrifugal migration of inner retinal layers, which counteracts in some way the centripetal packing of cone photoreceptors.
Morphologic analysis of artifacts in human fetal eyes confounding histopathologic investigations.
Herwig, Martina C; Müller, Annette M; Holz, Frank G; Loeffler, Karin U
2011-04-25
Human fetal eyes are an excellent source for studies of the normal ocular development and for examining early ocular changes associated with various syndromes in the context of a pediatric pathologic or prenatal sonographic diagnosis. However, artifacts caused by different factors often render an exact interpretation difficult. In this study, the frequency and extent of artifacts in human fetal eyes were investigated with the aim of distinguishing more precisely these artifacts from real findings, allowing also for a more diligent forensic interpretation. The cohort included 341 fetal eyes, ranging in age from 8 to 38 weeks of gestation, that were investigated macroscopically and by light microscopy. In most specimens, artifacts such as pigment spillage and autolytic changes of the retina were noted. Nearly all specimens showed changes of the lens with remarkable similarities to cataractous lenses in adult eyes. Structural ocular changes associated with systemic syndromes were also observed and in most instances could be distinguished from artifacts. Morphologic changes in fetal eyes should be classified in artifacts caused by way of abortion, mechanical effects from the removal of the eyes, delayed fixation with autolysis, and the fixative itself and should be distinguished from genuine structural abnormalities associated with ocular or systemic disease. This classification can be fairly difficult and requires experience. In addition, lens artifacts are often misleading, and the diagnosis of a fetal cataract should not be made based on histopathologic examination alone.
Ocular abnormalities in mice lacking the immunoglobulin superfamily member Cdo.
Zhang, Wei; Mulieri, Philip J; Gaio, Ursula; Bae, Gyu-Un; Krauss, Robert S; Kang, Jong-Sun
2009-10-01
Vertebrate eye development requires a series of complex morphogenetic and inductive events to produce a lens vesicle centered within the bilayered optic cup and a posteriorly positioned optic stalk. Multiple congenital eye defects, including microphthalmia and coloboma, result from defects in early eye morphogenesis. Cdo is a multifunctional cell surface immunoglobulin superfamily member that interacts with and mediates signaling by cadherins and netrins to regulate myogenesis. In addition, Cdo plays an essential role in early forebrain development by functioning as coreceptor for sonic hedgehog. It is reported here that Cdo is expressed in a dynamic, but dorsally restricted, fashion during early eye development, and that mice lacking Cdo display multiple eye defects. Anomalies seen in Cdo(-/-) mice include coloboma (failure to close the optic fissure); failure to form a proper boundary between the retinal pigmented epithelium and optic stalk; defective lens formation, including failure to separate from the surface ectoderm; and microphthalmia. Consistent with this wide array of defects, developing eyes of Cdo(-/-) mice show altered expression of several regulators of dorsoventral eye patterning, including Pax6, Pax2, and Tbx5. Taken together, these findings show that Cdo is required for normal eye development and is required for normal expression of patterning genes in both the ventral and dorsal domains. The multiple eye development defects seen in Cdo(-/-) mice suggest that mutations in human Cdo could contribute to congenital eye anomalies, such as Jacobsen syndrome, which is frequently associated with ocular defects, including coloboma and Peters' anomaly.
Ito, Norie; Barnes, Graham R; Fukushima, Junko; Fukushima, Kikuro; Warabi, Tateo
2013-08-01
Using a cue-dependent memory-based smooth-pursuit task previously applied to monkeys, we examined the effects of visual motion-memory on smooth-pursuit eye movements in normal human subjects and compared the results with those of the trained monkeys. These results were also compared with those during simple ramp-pursuit that did not require visual motion-memory. During memory-based pursuit, all subjects exhibited virtually no errors in either pursuit-direction or go/no-go selection. Tracking eye movements of humans and monkeys were similar in the two tasks, but tracking eye movements were different between the two tasks; latencies of the pursuit and corrective saccades were prolonged, initial pursuit eye velocity and acceleration were lower, peak velocities were lower, and time to reach peak velocities lengthened during memory-based pursuit. These characteristics were similar to anticipatory pursuit initiated by extra-retinal components during the initial extinction task of Barnes and Collins (J Neurophysiol 100:1135-1146, 2008b). We suggest that the differences between the two tasks reflect differences between the contribution of extra-retinal and retinal components. This interpretation is supported by two further studies: (1) during popping out of the correct spot to enhance retinal image-motion inputs during memory-based pursuit, pursuit eye velocities approached those during simple ramp-pursuit, and (2) during initial blanking of spot motion during memory-based pursuit, pursuit components appeared in the correct direction. Our results showed the importance of extra-retinal mechanisms for initial pursuit during memory-based pursuit, which include priming effects and extra-retinal drive components. Comparison with monkey studies on neuronal responses and model analysis suggested possible pathways for the extra-retinal mechanisms.
Wave aberrations in rhesus monkeys with vision-induced ametropias
Ramamirtham, Ramkumar; Kee, Chea-su; Hung, Li-Fang; Qiao-Grider, Ying; Huang, Juan; Roorda, Austin; Smith, Earl L.
2007-01-01
The purpose of this study was to investigate the relationship between refractive errors and high-order aberrations in infant rhesus monkeys. Specifically, we compared the monochromatic wave aberrations measured with a Shack-Hartman wavefront sensor between normal monkeys and monkeys with vision-induced refractive errors. Shortly after birth, both normal monkeys and treated monkeys reared with optically induced defocus or form deprivation showed a decrease in the magnitude of high-order aberrations with age. However, the decrease in aberrations was typically smaller in the treated animals. Thus, at the end of the lens-rearing period, higher than normal amounts of aberrations were observed in treated eyes, both hyperopic and myopic eyes and treated eyes that developed astigmatism, but not spherical ametropias. The total RMS wavefront error increased with the degree of spherical refractive error, but was not correlated with the degree of astigmatism. Both myopic and hyperopic treated eyes showed elevated amounts of coma and trefoil and the degree of trefoil increased with the degree of spherical ametropia. Myopic eyes also exhibited a much higher prevalence of positive spherical aberration than normal or treated hyperopic eyes. Following the onset of unrestricted vision, the amount of high-order aberrations decreased in the treated monkeys that also recovered from the experimentally induced refractive errors. Our results demonstrate that high-order aberrations are influenced by visual experience in young primates and that the increase in high-order aberrations in our treated monkeys appears to be an optical byproduct of the vision-induced alterations in ocular growth that underlie changes in refractive error. The results from our study suggest that the higher amounts of wave aberrations observed in ametropic humans are likely to be a consequence, rather than a cause, of abnormal refractive development. PMID:17825347
Hood, A S; Morrison, J D
2002-01-01
We have measured monocular and binocular contrast sensitivities in response to medium to high spatial frequencies of vertical sinusoidal grating patterns in normal subjects, anisometropic amblyopes, strabismic amblyopes and non-amblyopic esotropes. On binocular viewing, contrast sensitivities were slightly but significantly increased in normal subjects, markedly increased in anisometropes and esotropes with anomalous binocular single vision (BSV) and significantly reduced in esotropes and exotropes without BSV. Application of a prismatic correction to the strabismic eye in order to achieve bifoveal stimulation resulted in a significant reduction in contrast sensitivity in esotropes with and without anomalous BSV, in exotropes and in non-amblyopic esotropes. Control experiments in normal subjects with monocular viewing showed that degradative effects of the prism occurred only with high prism powers and at high spatial frequencies, thus establishing that the reduced contrast sensitivities were the consequence of bifoveal stimulation rather than optical degradation. Displacement of the image of the grating pattern by 2 deg in normal subjects and anisometropes by a dichoptic method to simulate a small angle esotropia had no effect on the contrast sensitivities recorded through the companion eye. By contrast, esotropes showed similar reductions in contrast sensitivity to those obtained with the prism experiments, confirming a fundamental difference between subjects with normal and abnormal ocular alignments. The results have thus established a suppressive action of the fovea of the amblyopic eye acting on the companion, non-amblyopic eye and indicate that correction of ocular misalignments in adult esotropes may be disadvantageous to binocular visual performance. PMID:11956347
Effects of the holmium laser on the human cornea: a preliminary study
NASA Astrophysics Data System (ADS)
Mueller, Linda J.; Tassignon, Marie J.; Trau, Rene; Pels, Liesbeth; Vrensen, Gijs F.
1996-12-01
Treatment of peripheral post-mortem human corneas with the Holmium laser in a ring pattern resulted in opaque spots. One pair of treated eyes was immediately processed for light and electron microscopy and three other treated eyes were preserved for 4 days in medium in order to compare direct and short-term effects of the Holmium laser. Cross as well as frontal light microscopical sections of all eyes revealed interconnecting bands between the spots. At the ultrastructural level the anterior corneal tissue within these spots was characterized by coagulation of cells and collagen and shoed either a dramatic distorting effect on the epithelium in the eyes processed immediately or a single layer of flattened multi-nucleolated epithelial cells having more than one nucleolus per nucleus in the eyes stored in medium. Furthermore, the spots showed disturbed Bowman's layer, destroyed keratocytes and collagen fibrils which were either coagulated or organized chaotically. The interconnecting bands contained alternating normal and coagulated collagen fibers. The rest of the cornea outside the spots had a normal appearance. In corneas stored in medium, both keratocytes and epithelial cells over the entire cornea exhibited accumulations of cytoplasmic fibrils and glycogen particles. These phenomena were not observed in non-preserved corneas, suggesting that the differences are due to preservation and not due to the laser treatment. It is concluded that morphological changes occur mainly in the treated peripheral cornea whereas the central untreated cornea remains unaffected,indicating that the Holmium laser is a reliable instrument to treat hypermetropic patients.
van den Berg, Thomas J T P
2017-05-01
The effect of cataract and other media opacities on functional vision is typically assessed clinically using visual acuity. In both clinical and basic research, straylight (the functional result of light scattering in the eye) is commonly measured. The purpose of the present study was to determine the link between these two measures: is visual acuity in cataract and other media opacities related to straylight? Interdependence between acuity and straylight is addressed from three different points of view: (1) Methodological: can acuity differences affect the measurement value of straylight, and vice versa? (2) Basic optics: does the optical process of light scattering in the human eye affect both straylight and visual acuity? (3) Statistical: how strongly are acuity and straylight correlated in the practice of important clinical conditions? Experimental and theoretical aspects will be considered, with a focus on normal ageing and cataract formation. (1) Methodological: testing potential effects of acuity, artificially manipulated with positive trial lenses, showed no effect on measured straylight values. Since light scattering in the eye involves a low percentage of the light and has large angular spreading, contrast reduction due to straylight is limited, resulting in virtually absent acuity effects. (2) Basic optics: light scattering from the human donor eye lens is found to have virtually no effect in the centre of the point-spread-function, also for cataractous lenses, resulting in virtually absent acuity effects. (3) Statistical: literature data on straylight and visual acuity show a weak correlation for the important groups of normal ageing and cataract populations. The point-spread-function of the normal ageing and cataractous human eye is built upon two rather independent basic parts. Aberrations control the central peak. Light scattering controls the periphery from about 1° onwards. The way acuity and straylight are measured ensures no confounding between them. Statistically within the normal ageing and cataract populations, visual acuity and straylight vary quite independently from each other. Visual acuity losses with cataract and other media opacities are not due to straylight, but caused by aberrations and micro-aberrations. Straylight defines disability glare, and causes symptoms of glare, haloes, hazy vision etc. Overall, visual acuity and straylight are rather independent aspects of quality of vision. © 2017 The Author Ophthalmic & Physiological Optics © 2017 The College of Optometrists.
Paulsen, Friedrich; Langer, Gesa; Hoffmann, Werner; Berry, Monica
2004-05-01
The objective of this study was to determine whether the lacrimal gland synthesizes mucins and whether they are changed with age or in cases of dry eye. Expression of mucins in human lacrimal glands was monitored by reverse transcription-polymerase chain reaction analysis. Furthermore, the presence and distribution of MUC1, -2, -4, -5AC, -5B, -6 and -7 in epithelia of the human lacrimal gland and its excretory duct system were assessed with antisera to mucin peptide cores. Thirty normal tissues from cadavers of different ages were tested, plus four with dry eye treated with artificial tears. Expression studies detected mRNAs for mucins MUC1, -4, -5AC, -5B, -6 and -7; whereas the MUC2 message was absent. The message for MUC4 was present in all four cases of dry eye, but only in six out of the 30 normal glands from individuals who did not receive artificial tears. MUC6 mRNA was detected only in about half of the investigated samples. Immunohistochemistry revealed membrane-bound MUC1 at the apical surface of acinar cells, absence of MUC2, MUC5AC associated with goblet cells of excretory ducts, MUC5B and -7 in the cytoplasm of acinar cells, and MUC7 also in epithelial cells of excretory ducts. MUC4 mucin was detected only in those individuals in which message was identified. In dry eyes, MUC5AC and -5B were localized in the same acinar cells; whereas MUC2 and MUC6 were not detectable. Dot-blot analysis clearly revealed increased amounts of MUC4, -5AC, and -5B in the glands of elderly women who received treatment for dry eyes. These results confirm that the human lacrimal gland synthesizes a spectrum of mucins; part of them might be correlated with age. Copyright 2004 Springer-Verlag
Barnes, D A; Dunne, M C; Clement, R A
1987-01-01
The relative contributions of translation and rotation of the cornea and lens to peripheral astigmatic asymmetry have been investigated using a linear algebraic ray tracing method. It is believed that lenticular rotation is responsible for angle alpha, so bringing about peripheral astigmatic asymmetry, as normally occurs in human eyes over the temporal and nasal retina. Rotation of the cornea may be responsible for the small numbers of eyes which exhibit large amounts of peripheral astigmatic asymmetry. The effects of corneal rotation and translation on the dimensions of the entrance pupil are illustrated.
Ragsdale, Gillian; Foley, Robert A.
2011-01-01
Background Parent-of-origin effects have been found to influence the mammalian brain and cognition and have been specifically implicated in the development of human social cognition and theory of mind. The experimental design in this study was developed to detect parent-of-origin effects on theory of mind, as measured by the ‘Reading the mind in the eyes’ (Eyes) task. Eyes scores were also entered into a principal components analysis with measures of empathy, social skills and executive function, in order to determine what aspect of theory of mind Eyes is measuring. Methodology/Principal Findings Maternal and paternal influences on Eyes scores were compared using correlations between pairs of full (70 pairs), maternal (25 pairs) and paternal siblings (15 pairs). Structural equation modelling supported a maternal influence on Eyes scores over the normal range but not low-scoring outliers, and also a sex-specific influence on males acting to decrease male Eyes scores. It was not possible to differentiate between genetic and environmental influences in this particular sample because maternal siblings tended to be raised together while paternal siblings were raised apart. The principal components analysis found Eyes was associated with measures of executive function, principally behavioural inhibition and attention, rather than empathy or social skills. Conclusions/Significance In conclusion, the results suggest a maternal influence on Eye scores in the normal range and a sex-specific influence acting to reduce scores in males. This influence may act via aspects of executive function such as behavioural inhibition and attention. There may be different influences acting to produce the lowest Eyes scores which implies that the heratibility and/or maternal influence on poor theory of mind skills may be qualitatively different to the influence on the normal range. PMID:21850264
Precision Pulse Capsulotomy: Preclinical Safety and Performance of a New Capsulotomy Technology.
Chang, David F; Mamalis, Nick; Werner, Liliana
2016-02-01
To assess the preclinical safety and performance of a new precision pulse capsulotomy (PPC) method. Human cadaver eye studies and surgical, slit-lamp, and histopathologic evaluation in a consecutive series of 20 live rabbits. Human cadaver eyes and New Zealand white rabbits. Precision pulse capsulotomy uses a highly focused, fast, multipulse, low-energy discharge to produce a perfectly round anterior capsulotomy instantaneously and simultaneously along all 360°. Capsulotomies are performed using a disposable handpiece with a soft collapsible tip and circular nitinol cutting element. Miyake-Apple imaging and scanning electron microscopy (SEM) of PPC were conducted in human cadaver eyes. Surgical, postoperative slit-lamp, and histopathologic assessments of PPC were performed in 20 live rabbits and were compared with manual continuous curvilinear capsulorrhexis (CCC) in the fellow eye. Anterior chamber (AC) thermocouple temperature measurements were evaluated in a subset of rabbit eyes. Capsulotomy edge circularity, SEM morphologic features and zonular movement with PPC in human cadaver eyes. Anterior chamber temperature during PPC and grading of ocular inflammation, corneal endothelial damage, anterior capsular opacification (ACO), and posterior capsular opacification (PCO). Miyake-Apple imaging showed minimal zonular stress, and thermocouple measurements demonstrated negligible AC temperature changes during PPC. Precision pulse capsulotomy produced round, complete capsulotomies in all 20 rabbit eyes, leading to successful in-the-bag intraocular lens (IOL) implantation. Slit-lamp examinations at 3 days and 1, 2, and 4 weeks after surgery showed no significant differences between PPC and CCC in corneal edema, AC inflammatory reaction, capsular fibrosis, ACO, and PCO. Postmortem studies showed no difference in the corneal endothelium between PPC and CCC eyes. All IOLs were well centered in PPC eyes, and histopathologic analysis showed no greater inflammatory infiltrates. Precision pulse capsulotomy is a new method to automate consistent creation of a perfectly circular anterior capsulotomy with a disposable handheld instrument that can be used in the normal phacoemulsification surgical sequence. Compared with CCC in fellow rabbit eyes, PPC was equally safe and showed no greater zonular stress compared with CCC in human cadaver eyes. Human cadaver eye SEM showed a much smoother capsulotomy edge compared to those produced by femtosecond laser. Copyright © 2016 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
Postanaesthetic tear production and ocular irritation in cats.
Peche, N; Köstlin, R; Reese, S; Pieper, K
2015-01-01
General anaesthesia significantly reduces tear production and normal values are not immediately re-established on ending anaesthesia. Therefore, adequate protection of the cornea has to be assured during the perianaesthetic period. There are various methods available, including taping of the eyelids and the application of eye ointments, gels and drops. In human medicine studies, different formulations were found to induce signs of ocular irritation. The aim of the present study was to determine tear production in cats after general anaesthesia, and to identify possible causes of irritation. Tear production was determined in 41 cats after general anaesthesia and eyes were examined for signs of irritation. Two different anaesthetic protocols were used. To protect the cornea, an ointment and gel were applied to the right and left eyes, respectively. Postoperatively, tear production was significantly reduced for 6 hours and 18 hours in the right and left eyes, respectively. Two hours after anaesthesia, blepharospasm of the right eye was observed in 92.7% (n = 38) of the cats. In contrast, the left eye was always held open. This study demonstrated that tear production in cats is significantly decreased both during and after anaesthesia. The degree of reduction was independent of the anaesthetic protocol. Both the eye ointment and gel proved effective in protecting the corneal surface. However, eye gel use is recommended because the eye ointment consistently caused an irritation comparable to the foreign-body sensation reported in humans.
Neely, David; Zarubina, Anna V; Clark, Mark E; Huisingh, Carrie E; Jackson, Gregory R; Zhang, Yuhua; McGwin, Gerald; Curcio, Christine A; Owsley, Cynthia
2017-07-01
To examine the association between subretinal drusenoid deposits (SDDs) identified by multimodal retinal imaging and visual function in older eyes with normal macular health or in the earliest phases of age-related macular degeneration (AMD). Age-related macular degeneration status for each eye was defined according to the Age-Related Eye Disease Study (AREDS) 9-step classification system (normal = Step 1, early AMD = Steps 2-4) based on color fundus photographs. Visual functions measured were best-corrected photopic visual acuity, contrast and light sensitivity, mesopic visual acuity, low-luminance deficit, and rod-mediated dark adaptation. Subretinal drusenoid deposits were identified through multimodal imaging (color fundus photographs, infrared reflectance and fundus autofluorescence images, and spectral domain optical coherence tomography). The sample included 1,202 eyes (958 eyes with normal health and 244 eyes with early AMD). In normal eyes, SDDs were not associated with any visual function evaluated. In eyes with early AMD, dark adaptation was markedly delayed in eyes with SDDs versus no SDD (a 4-minute delay on average), P = 0.0213. However, this association diminished after age adjustment, P = 0.2645. Other visual functions in early AMD eyes were not associated with SDDs. In a study specifically focused on eyes in normal macular health and in the earliest phases of AMD, early AMD eyes with SDDs have slower dark adaptation, largely attributable to the older ages of eyes with SDD; they did not exhibit deficits in other visual functions. Subretinal drusenoid deposits in older eyes in normal macular health are not associated with any visual functions evaluated.
DOE Office of Scientific and Technical Information (OSTI.GOV)
C Hann; M Bentley; A Vercnocke
2011-12-31
The site of outflow resistance leading to elevated intraocular pressure in primary open-angle glaucoma is believed to be located in the region of Schlemm's canal inner wall endothelium, its basement membrane and the adjacent juxtacanalicular tissue. Evidence also suggests collector channels and intrascleral vessels may have a role in intraocular pressure in both normal and glaucoma eyes. Traditional imaging modalities limit the ability to view both proximal and distal portions of the trabecular outflow pathway as a single unit. In this study, we examined the effectiveness of three-dimensional micro-computed tomography (3D micro-CT) as a potential method to view the trabecularmore » outflow pathway. Two normal human eyes were used: one immersion fixed in 4% paraformaldehyde and one with anterior chamber perfusion at 10 mmHg followed by perfusion fixation in 4% paraformaldehyde/2% glutaraldehyde. Both eyes were postfixed in 1% osmium tetroxide and scanned with 3D micro-CT at 2 {mu}m or 5 {mu}m voxel resolution. In the immersion fixed eye, 24 collector channels were identified with an average orifice size of 27.5 {+-} 5 {mu}m. In comparison, the perfusion fixed eye had 29 collector channels with a mean orifice size of 40.5 {+-} 13 {mu}m. Collector channels were not evenly dispersed around the circumference of the eye. There was no significant difference in the length of Schlemm's canal in the immersed versus the perfused eye (33.2 versus 35.1 mm). Structures, locations and size measurements identified by 3D micro-CT were confirmed by correlative light microscopy. These findings confirm 3D micro-CT can be used effectively for the non-invasive examination of the trabecular meshwork, Schlemm's canal, collector channels and intrascleral vasculature that comprise the distal outflow pathway. This imaging modality will be useful for non-invasive study of the role of the trabecular outflow pathway as a whole unit.« less
Yusof, Nor Zuliana; Abd Gani, Siti Salwa; Azizul Hasan, Zafarizal Aldrin; Idris, Zainab
2018-01-01
Many types of phytochemicals have been found to be present in oil palm leaf and could potentially be used as functional ingredients for skincare product. However, as of today, there is no published report on hazard identification and safety assessment of oil palm ( Elaeis guineensis) leaf extract (OPLE), particularly on skin and eye irritation. In this study, potential hazard of OPLE on skin and eye irritation was evaluated as an initial step to the safety assessment of OPLE. In vitro cell viability study of OPLE on normal human dermal fibroblasts showed that OPLE was nontoxic to the cells with percentage viability more than 90% after 24 and 48 hours of incubation. Skin irritation potential of OPLE was evaluated using in vitro SkinEthic reconstructed human epidermis (RHE) model (Organization for Economic Cooperation and Development [OECD] Test Guideline 439, 2015), while eye irritation potential was evaluated using in vitro SkinEthic Human corneal epithelium (HCE) model (OECD test guideline 492, 2017). Hazard identification results showed that OPLE at 1%, 5%, and 10% (wt/wt) was classified as nonirritant to the skin and eye where mean tissue viabilities of SkinEthic RHE and SkinEthic HCE were more than 50% and 60%, respectively. Therefore, we recommend a further safety assessment, such as human patch testing, to confirm the nonirritant of OPLE.
The neural basis of suppression and amblyopia in strabismus.
Sengpiel, F; Blakemore, C
1996-01-01
The neurophysiological consequences of artificial strabismus in cats and monkeys have been studied for 30 years. However, until very recently no clear picture has emerged of neural deficits that might account for the powerful interocular suppression that strabismic humans experience, nor for the severe amblyopia that is often associated with convergent strabismus. Here we review the effects of squint on the integrative capacities of the primary visual cortex and propose a hypothesis about the relationship between suppression and amblyopia. Most neurons in the visual cortex of normal cats and monkeys can be excited through either eye and show strong facilitation during binocular stimulation with contours of similar orientation in the two eyes. But in strabismic animals, cortical neurons tend to fall into two populations of monocularly excitable cells and exhibit suppressive binocular interactions that share key properties with perceptual suppression in strabismic humans. Such interocular suppression, if prolonged and asymmetric (with input from the squinting eye habitually suppressed by that from the fixating eye), might lead to neural defects in the representation of the deviating eye and hence to amblyopia.
Karimi, Alireza; Razaghi, Reza; Navidbakhsh, Mahdi; Sera, Toshihiro; Kudo, Susumu
2016-05-01
In spite the fact that a very small human body surface area is comprised by the eye, its wounds due to detonation have recently been dramatically amplified. Although many efforts have been devoted to measure injury of the globe, there is still a lack of knowledge on the injury mechanism due to Primary Blast Wave (PBW). The goal of this study was to determine the stresses and deformations of the human eye components, including the cornea, aqueous, iris, ciliary body, lens, vitreous, retina, sclera, optic nerve, and muscles, attributed to PBW induced by trinitrotoluene (TNT) explosion via a Lagrangian-Eulerian computational coupling model. Magnetic Resonance Imaging (MRI) was employed to establish a Finite Element (FE) model of the human eye according to a normal human eye. The solid components of the eye were modelled as Lagrangian mesh, while an explosive TNT, air domain, and aqueous were modelled using Arbitrary Lagrangian-Eulerian (ALE) mesh. Nonlinear dynamic FE simulations were accomplished using the explicit FE code, namely LS-DYNA. In order to simulate the blast wave generation, propagation, and interaction with the eye, the ALE formulation with Jones-Wilkins-Lee (JWL) equation defining the explosive material were employed. The results revealed a peak stress of 135.70kPa brought about by detonation upsurge on the cornea at the distance of 25cm. The highest von Mises stresses were observed on the sclera (267.3kPa), whereas the lowest one was seen on the vitreous body (0.002kPa). The results also showed a relatively high resultant displacement for the macula as well as a high variation for the radius of curvature for the cornea and lens, which can result in both macular holes, optic nerve damage and, consequently, vision loss. These results may have implications not only for understanding the value of stresses and strains in the human eye components but also giving an outlook about the process of PBW triggers damage to the eye. Copyright © 2016 Elsevier Ltd. All rights reserved.
Spatial and spectral analysis of corneal epithelium injury using hyperspectral images
NASA Astrophysics Data System (ADS)
Md Noor, Siti Salwa; Michael, Kaleena; Marshall, Stephen; Ren, Jinchang
2017-12-01
Eye assessment is essential in preventing blindness. Currently, the existing methods to assess corneal epithelium injury are complex and require expert knowledge. Hence, we have introduced a non-invasive technique using hyperspectral imaging (HSI) and an image analysis algorithm of corneal epithelium injury. Three groups of images were compared and analyzed, namely healthy eyes, injured eyes, and injured eyes with stain. Dimensionality reduction using principal component analysis (PCA) was applied to reduce massive data and redundancies. The first 10 principal components (PCs) were selected for further processing. The mean vector of 10 PCs with 45 pairs of all combinations was computed and sent to two classifiers. A quadratic Bayes normal classifier (QDC) and a support vector classifier (SVC) were used in this study to discriminate the eleven eyes into three groups. As a result, the combined classifier of QDC and SVC showed optimal performance with 2D PCA features (2DPCA-QDSVC) and was utilized to classify normal and abnormal tissues, using color image segmentation. The result was compared with human segmentation. The outcome showed that the proposed algorithm produced extremely promising results to assist the clinician in quantifying a cornea injury.
Tusa, R J; Mustari, M J; Burrows, A F; Fuchs, A F
2001-08-01
The normal development and the capacity to calibrate gaze-stabilizing systems may depend on normal vision during infancy. At the end of 1 yr of dark rearing, cats have gaze-stabilizing deficits similar to that of the newborn human infant including decreased monocular optokinetic nystagmus (OKN) in the nasal to temporal (N-T) direction and decreased velocity storage in the vestibuloocular reflex (VOR). The purpose of this study is to determine to what extent restricted vision during the first 2 mo of life in monkeys affects the development of gaze-stabilizing systems. The eyelids of both eyes were sutured closed in three rhesus monkeys (Macaca mulatta) at birth. Eyelids were opened at 25 days in one monkey and 40 and 55 days in the other two animals. Eye movements were recorded from each eye using scleral search coils. The VOR, OKN, and fixation were examined at 6 and 12 mo of age. We also examined ocular alignment, refraction, and visual acuity in these animals. At 1 yr of age, visual acuity ranged from 0.3 to 0.6 LogMAR (20/40-20/80). All animals showed a defect in monocular OKN in the N-T direction. The velocity-storage component of OKN (i.e., OKAN) was the most impaired. All animals had a mild reduction in VOR gain but had a normal time constant. The animals deprived for 40 and 55 days had a persistent strabismus. All animals showed a nystagmus similar to latent nystagmus (LN) in human subjects. The amount of LN and OKN defect correlated positively with the duration of deprivation. In addition, the animal deprived for 55 days demonstrated a pattern of nystagmus similar to congenital nystagmus in human subjects. We found that restricted visual input during the first 2 mo of life impairs certain gaze-stabilizing systems and causes LN in primates.
Thienprasiddhi, Phamornsak; Greenstein, Vivienne C; Chu, David H; Xu, Li; Liebmann, Jeffrey M; Ritch, Robert; Hood, Donald C
2006-08-01
To determine whether the multifocal visual evoked potential (mfVEP) technique can detect early functional damage in ocular hypertensive (OHT) and glaucoma suspect (GS) patients with normal standard achromatic automated perimetry (SAP) results. Twenty-five GS patients (25 eyes), 25 patients with OHT (25 eyes), and 50 normal controls (50 eyes) were enrolled in this study. All GS, OHT and normal control eyes had normal SAP as defined by a pattern standard deviation and mean deviation within the 95% confidence interval and a glaucoma hemifield test within normal limits on the Humphrey visual field 24-2 program. Eyes with GS had optic disc changes consistent with glaucoma with or without raised intraocular pressure (IOP), and eyes with OHT showed no evidence of glaucomatous optic neuropathy and IOPs >or=22 mm Hg. Monocular mfVEPs were obtained from both eyes of each subject using a pattern-reversal dartboard array with 60 sectors. The entire display had a radius of 22.3 degrees. The mfVEPs, for each eye, were defined as abnormal when either the monocular or interocular probability plot had a cluster of 3 or more contiguous points with P<0.05 and at least 2 of these points with P<0.01. The mfVEP results were abnormal in 4% of the eyes from normal subjects. Abnormal mfVEPs were detected in 20% of the eyes of GS patients and 16% of the eyes of OHT patients. Significantly more mfVEP abnormalities were detected in GS patients than in normal controls. However, there was no significant difference in mfVEP results between OHT patients and normal controls. The mfVEP technique can detect visual field deficits in a minority of eyes with glaucomatous optic disks and normal SAP results.
The role of crumbs genes in the vertebrate cornea.
Beyer, Jill; Zhao, Xinping C; Yee, Richard; Khaliq, Shagufta; McMahon, Timothy T; Ying, Hongyu; Yue, Beatrice Y J T; Malicki, Jarema J
2010-09-01
To evaluate the role of crumbs genes and related epithelial polarity loci in the vertebrate cornea. The authors used histologic analysis and electron microscopy to evaluate the corneas of zebrafish mutant for a crumbs locus oko meduzy (ome) and in mutants of four other loci, nagie oko (nok), heart and soul (has), mosaic eyes (moe), and ncad (formerly glass onion), that function in the same or related genetic pathways. In parallel, they performed an evaluation of corneas in human carriers of a crumbs gene, CRB1, and mutations using topography and biomicroscopy. The expression of the CRB1 gene in the normal human cornea was examined by polymerase chain reaction (PCR) and immunohistochemical staining. The corneas of zebrafish mutants display severe abnormalities of the epithelial and stromal layers. The epithelial cells do not properly adhere to each other, and fluid-filled spaces form between them. In addition, the layering of the corneal stroma is poorly formed or absent. The corneas of human carriers of CRB1 mutations display shape deviations compared with what has been observed in normal individuals. A PCR product of the correct size was obtained from normal human corneal samples. Sequence analyses confirmed its identity to be the human CRB1 gene. Immunohistochemical staining using anti-CRB1 yielded positive brown deposits in the human cornea. crumbs genes play a role in the differentiation of the vertebrate cornea. Corneal defects associated with crumbs gene mutations are very severe in the zebrafish model and, in comparison, appear clinically less pronounced in the human eye.
Gilger, Brian C; Yang, Ping; Salmon, Jacklyn H; Jaffe, Glenn J; Allen, Janice B
2002-07-01
To determine whether a chemokine (RANTES)-like protein expressed by ciliary epithelium plays a role in uveitis. 3 clinically normal horses intradermal, 5 eyes from 5 horses with recurrent uveitis, and 10 normal eyes from 5 age- and sex-matched horses. Cross-reactivity and sensitivity of recombinant human (rh)-regulated upon activation, normal T-cell expressed and secreted (RANTES) protein were evaluated in horses by use of intradermal hypersensitivity reactions and a chemotaxis assay. Aqueous humor and ciliary body of eyes from clinically normal horses and horses with uveitis were examined for RANTES expression by use of an ELISA and reverse transcription-polymerase chain reaction (RT-PCR). Expression of RANTES mRNA and protein content of primary cultures of equine ciliary pigmented epithelial cells (RT-PCR) and culture supernatant (ELISA) were measured 6 or 24 hours, respectively, after cultures were stimulated with interleukin-1beta and tumor necrosis factor-alpha. Strong reactions to intradermal hypersensitivity testing and significant chemotaxis of equine leukocytes to rh-RANTES wereas observed. Aqueous humor of eyes from horses with uveitis contained increased concentrations of rh-RANTES-like protein (mean +/- SD, 45.9+/-31.7 pg/ml), compared with aqueous humor from clinically normal horses (0 pg/ml). Ciliary body from horses with uveitis expressed RANTES mRNA, whereas ciliary body from clinically normal horses had low mRNA expression. Stimulated ciliary pigmented epithelial cells expressed increased amounts of rh-RANTES-like protein (506.1+/-298.3 pg/ml) and mRNA, compared with unstimulated samples. Ciliary epithelium may play a role in recruitment and activation of leukocytes through expression of RANTES.
Morphometric assessment of normal human ciliary body using ultrasound biomicroscopy.
Okamoto, Yoshifumi; Okamoto, Fumiki; Nakano, Shinichiro; Oshika, Tetsuro
2017-12-01
To quantitatively assess the biometry of the ciliary body in normal human eyes using ultrasound biomicroscopy. We evaluated 85 eyes of 85 normal subjects (35 men and 50 women), whose age ranged from 11 to 86 years (mean ± SD, 56.8 ± 20.4 years). The eyes were assessed along the 3-, 6-, 9-, and 12-o'clock meridians relative to the center of the cornea. Clinical data were collected, including age, axial length, ciliary body length (CBL), ciliary body thickness (CBT), anterior chamber depth, iris root thickness, trabecular-iris angle, and scleral-ciliary process angle. Axial length was measured using A-scan ultrasonography. CBL and CBT tended to be larger in the superior than in the inferior quadrant, but the differences among the four quadrants were not statistically significant. The average CBL showed a significant positive correlation with the average CBT (r = 0.40, P < 0.001). Average CBL and CBT were significantly correlated with axial length (r = 0.33, P = 0.031; r = 0.46, P < 0.01 respectively). In addition, the average CBL was significantly correlated with anterior chamber depth (r = 0.23, P < 0.05), trabecular-iris angle (r = 0.29, P = 0.01), and scleral-ciliary process angle (r = 0.40, P < 0.001). Ultrasound biomicroscopic imaging demonstrated that the ciliary body is similar in size in all circumferences, and eyes with longer axial length have an elongated and thicker ciliary body. The values obtained in the present study may serve as standard clinical references.
Mrugacz, Malgorzata; Bakunowicz-Lazarczyk, Alina
2005-01-01
The aim of this study was to quantitatively assess and compare the thickness of the retinal nerve fiber layer (RNFL) in normal and glaucomatous eyes of children using the optical coherence tomograph. The mean RNFL thickness of normal eyes (n=26) was compared with that of glaucomatous eyes (n=26). The eyes were classified into diagnostic groups based on conventional ophthalmological physical examination, Humphrey 30-2 visual fields, stereoscopic optic nerve head photography, and optical coherence tomography. The mean RNFL was significantly thinner in glaucomatous eyes than in normal eyes: 95+/-26.3 and 132+/-24.5 microm, respectively. More specifically, the RNFL was significantly thinner in glaucomatous eyes than in normal eyes in the inferior quadrant: 87+/-23.5 and 122+/-24.2 microm, respectively. The mean and inferior quadrant RFNL thicknesses as measured by the optical coherence tomograph showed a statistically significant correlation with glaucoma. Optical coherence tomography may contribute to tracking of juvenile glaucoma progression. Copyright (c) 2005 S. Karger AG, Basel.
Bracha, H S; Seitz, D J; Otemaa, J; Glick, S D
1987-05-19
An endogenous asymmetry in striatal dopaminergic function has been identified in rats, and related to spontaneous and drug-induced circling (rotation, turning). We have developed an electronic device for measuring in humans the same kinds of rotational movements observed in rats. Our data indicate that, without being aware of the type of information being obtained, normal men and women rotate preferentially to the left or to the right during a routine day. Women had higher average rates of rotation than men. Males that were consistently right-sided (left-hemisphere dominant) for hand, foot and eye dominance rotated more to the right than to the left, whereas left-hemisphere dominant females rotated more to the left than to the right. Subjects tested on two occasions, 6 weeks apart, exhibited consistent (significantly correlated) rotational preferences--this was much more evident in left-hemisphere dominant than in mixed dominance individuals. In view of similar animal data, the device used in this study may become a useful and objective means for obtaining quantitative information regarding the status of basal ganglia function in humans.
Dong, Jing; Zhang, Yaqin; Zhang, Haining; Jia, Zhijie; Zhang, Suhua; Wang, Xiaogang
2018-01-01
To compare the axial length (AL), anterior chamber depth (ACD) and intraocular lens power (IOLP) of IOLMaster and Ultrasound in normal, long and short eyes. Seventy-four normal eyes (≥ 22 mm and ≤ 25 mm), 74 long eyes (> 25 mm) and 78 short eyes (< 22 mm) underwent AL and ACD measurements with both devices in the order of IOLMaster followed by Ultrasound. The IOLP were calculated using a free online LADAS IOL formula calculator. The difference in AL and IOLP between IOLMaster and Ultrasound was statistically significant when all three groups were combined. The difference in ACD between IOLMaster and Ultrasound was statistically significant in the normal group (P<0.001) and short eye group (P<0.001) but not the long eye group (P = 0.465). For the IOLP difference between IOLMaster and Ultrasound in the normal group, the percentage of IOLP differences <|0.5|D, ≥|0.5|D<|0.75|D, ≥|0.75|D<|1.0|D, and ≥|1.0|D were 90.5%, 8.1%, 1.4% and 0%, respectively. For the long eye group, they were 90.5%, 5.4%, 4.1% and 0%, respectively. For the short eye group, they were 61.5%, 23.1%, 10.3%, and 5.1%, respectively. IOLMaster and Ultrasound have statistically significant differences in AL measurements and IOLP (using LADAS formula) for normal, long eye and short eye. The two instruments agree regarding ACD measurements for the long eye group, but differ for the normal and short eye groups. Moreover, the high percentage of IOLP differences greater than |0.5|D in the short eye group is noteworthy.
Acuity-independent effects of visual deprivation on human visual cortex
Hou, Chuan; Pettet, Mark W.; Norcia, Anthony M.
2014-01-01
Visual development depends on sensory input during an early developmental critical period. Deviation of the pointing direction of the two eyes (strabismus) or chronic optical blur (anisometropia) separately and together can disrupt the formation of normal binocular interactions and the development of spatial processing, leading to a loss of stereopsis and visual acuity known as amblyopia. To shed new light on how these two different forms of visual deprivation affect the development of visual cortex, we used event-related potentials (ERPs) to study the temporal evolution of visual responses in patients who had experienced either strabismus or anisometropia early in life. To make a specific statement about the locus of deprivation effects, we took advantage of a stimulation paradigm in which we could measure deprivation effects that arise either before or after a configuration-specific response to illusory contours (ICs). Extraction of ICs is known to first occur in extrastriate visual areas. Our ERP measurements indicate that deprivation via strabismus affects both the early part of the evoked response that occurs before ICs are formed as well as the later IC-selective response. Importantly, these effects are found in the normal-acuity nonamblyopic eyes of strabismic amblyopes and in both eyes of strabismic patients without amblyopia. The nonamblyopic eyes of anisometropic amblyopes, by contrast, are normal. Our results indicate that beyond the well-known effects of strabismus on the development of normal binocularity, it also affects the early stages of monocular feature processing in an acuity-independent fashion. PMID:25024230
Design of optical system for binocular fundus camera.
Wu, Jun; Lou, Shiliang; Xiao, Zhitao; Geng, Lei; Zhang, Fang; Wang, Wen; Liu, Mengjia
2017-12-01
A non-mydriasis optical system for binocular fundus camera has been designed in this paper. It can capture two images of the same fundus retinal region from different angles at the same time, and can be used to achieve three-dimensional reconstruction of fundus. It is composed of imaging system and illumination system. In imaging system, Gullstrand Le Grand eye model is used to simulate normal human eye, and Schematic eye model is used to test the influence of ametropia in human eye on imaging quality. Annular aperture and black dot board are added into illumination system, so that the illumination system can eliminate stray light produced by corneal-reflected light and omentoscopic lens. Simulation results show that MTF of each visual field at the cut-off frequency of 90lp/mm is greater than 0.2, system distortion value is -2.7%, field curvature is less than 0.1 mm, radius of Airy disc is 3.25um. This system has a strong ability of chromatic aberration correction and focusing, and can image clearly for human fundus in which the range of diopters is from -10 D to +6 D(1 D = 1 m -1 ).
Binocular combination in abnormal binocular vision
Ding, Jian; Klein, Stanley A.; Levi, Dennis M.
2013-01-01
We investigated suprathreshold binocular combination in humans with abnormal binocular visual experience early in life. In the first experiment we presented the two eyes with equal but opposite phase shifted sine waves and measured the perceived phase of the cyclopean sine wave. Normal observers have balanced vision between the two eyes when the two eyes' images have equal contrast (i.e., both eyes contribute equally to the perceived image and perceived phase = 0°). However, in observers with strabismus and/or amblyopia, balanced vision requires a higher contrast image in the nondominant eye (NDE) than the dominant eye (DE). This asymmetry between the two eyes is larger than predicted from the contrast sensitivities or monocular perceived contrast of the two eyes and is dependent on contrast and spatial frequency: more asymmetric with higher contrast and/or spatial frequency. Our results also revealed a surprising NDE-to-DE enhancement in some of our abnormal observers. This enhancement is not evident in normal vision because it is normally masked by interocular suppression. However, in these abnormal observers the NDE-to-DE suppression was weak or absent. In the second experiment, we used the identical stimuli to measure the perceived contrast of a cyclopean grating by matching the binocular combined contrast to a standard contrast presented to the DE. These measures provide strong constraints for model fitting. We found asymmetric interocular interactions in binocular contrast perception, which was dependent on both contrast and spatial frequency in the same way as in phase perception. By introducing asymmetric parameters to the modified Ding-Sperling model including interocular contrast gain enhancement, we succeeded in accounting for both binocular combined phase and contrast simultaneously. Adding binocular contrast gain control to the modified Ding-Sperling model enabled us to predict the results of dichoptic and binocular contrast discrimination experiments and provides new insights into the mechanisms of abnormal binocular vision. PMID:23397039
Binocular combination in abnormal binocular vision.
Ding, Jian; Klein, Stanley A; Levi, Dennis M
2013-02-08
We investigated suprathreshold binocular combination in humans with abnormal binocular visual experience early in life. In the first experiment we presented the two eyes with equal but opposite phase shifted sine waves and measured the perceived phase of the cyclopean sine wave. Normal observers have balanced vision between the two eyes when the two eyes' images have equal contrast (i.e., both eyes contribute equally to the perceived image and perceived phase = 0°). However, in observers with strabismus and/or amblyopia, balanced vision requires a higher contrast image in the nondominant eye (NDE) than the dominant eye (DE). This asymmetry between the two eyes is larger than predicted from the contrast sensitivities or monocular perceived contrast of the two eyes and is dependent on contrast and spatial frequency: more asymmetric with higher contrast and/or spatial frequency. Our results also revealed a surprising NDE-to-DE enhancement in some of our abnormal observers. This enhancement is not evident in normal vision because it is normally masked by interocular suppression. However, in these abnormal observers the NDE-to-DE suppression was weak or absent. In the second experiment, we used the identical stimuli to measure the perceived contrast of a cyclopean grating by matching the binocular combined contrast to a standard contrast presented to the DE. These measures provide strong constraints for model fitting. We found asymmetric interocular interactions in binocular contrast perception, which was dependent on both contrast and spatial frequency in the same way as in phase perception. By introducing asymmetric parameters to the modified Ding-Sperling model including interocular contrast gain enhancement, we succeeded in accounting for both binocular combined phase and contrast simultaneously. Adding binocular contrast gain control to the modified Ding-Sperling model enabled us to predict the results of dichoptic and binocular contrast discrimination experiments and provides new insights into the mechanisms of abnormal binocular vision.
Consequences of Traumatic Brain Injury for Human Vergence Dynamics
Tyler, Christopher W.; Likova, Lora T.; Mineff, Kristyo N.; Elsaid, Anas M.; Nicholas, Spero C.
2015-01-01
Purpose: Traumatic brain injury involving loss of consciousness has focal effects in the human brainstem, suggesting that it may have particular consequences for eye movement control. This hypothesis was investigated by measurements of vergence eye movement parameters. Methods: Disparity vergence eye movements were measured for a population of 123 normally sighted individuals, 26 of whom had suffered diffuse traumatic brain injury (dTBI) in the past, while the remainder served as controls. Vergence tracking responses were measured to sinusoidal disparity modulation of a random-dot field. Disparity vergence step responses were characterized in terms of their dynamic parameters separately for the convergence and divergence directions. Results: The control group showed notable differences between convergence and divergence dynamics. The dTBI group showed significantly abnormal vergence behavior on many of the dynamic parameters. Conclusion: The results support the hypothesis that occult injury to the oculomotor control system is a common residual outcome of dTBI. PMID:25691880
Mapping the Perceptual Grain of the Human Retina
Tuten, William S.; Roorda, Austin; Sincich, Lawrence C.
2014-01-01
In humans, experimental access to single sensory receptors is difficult to achieve, yet it is crucial for learning how the signals arising from each receptor are transformed into perception. By combining adaptive optics microstimulation with high-speed eye tracking, we show that retinal function can be probed at the level of the individual cone photoreceptor in living eyes. Classical psychometric functions were obtained from cone-sized microstimuli targeted to single photoreceptors. Revealed psychophysically, the cone mosaic also manifests a variable sensitivity to light across its surface that accords with a simple model of cone light capture. Because this microscopic grain of vision could be detected on the perceptual level, it suggests that photoreceptors can act individually to shape perception, if the normally suboptimal relay of light by the eye's optics is corrected. Thus the precise arrangement of cones and the exact placement of stimuli onto those cones create the initial retinal limits on signals mediating spatial vision. PMID:24741057
Staining and peeling of the internal limiting membrane in the cat eye.
Gandorfer, Arnd; Rohleder, Matthias; Charteris, David G; Sethi, Charanjit; Kampik, Anselm; Luthert, Philip
2005-11-01
To investigate the cat vitreomacular interface using trypan blue (TB) and indocyanine green (ICG) and to determine the validity of the cat model in terms of staining and peeling of the internal limiting membrane (ILM). Lensectomy and vitrectomy were performed in four eyes of two cats. The ILM of two eyes was stained with TB (0.15%). ILM peeling was performed in one eye. Two eyes were stained with ICG (0.5%). One eye was illuminated for 3 min. Light and transmission electron microscopy and confocal microscopy were performed. Clinically, both dyes stained the cat ILM similar to human ILM. TB staining resulted in a normal ultrastructure and antigenity of the retina. ILM peeling was associated with intraretinal bleeding. There were fragments of Müller cells adherent to the retinal side of the ILM, and Müller cell endfeet were ruptured and avulsed. ICG staining of the ILM followed by illumination caused severe inner retinal damage. ICG without illumination resulted in focal ILM detachments associated with tearing of Müller cell endfeet. The cat can be used as a model to study the effect of TB and ICG on the central area of the cat retina, as previous results from clinical and experimental postmortem settings in human eyes were confirmed in the current study. Peeling of the ILM as a sheet as performed in human macular surgery is not feasible. Differences in the ultrastructure of the ILM and a strong adhesion of the ILM to Müller cell endfeet may account for this observation.
Ectopic Six3 expression in the dragon eye goldfish.
Ma, Dong-Mei; Zhu, Hua-Ping; Gui, Jian-Fang
2008-02-01
For goldfish (Carassius auratus), there are many varieties with different eye phenotypes due to artificial selection and adaptive evolution. Dragon eye is a variant eye characterized by a large-size eyeball protruding out of the socket similar to the eye of dragon in Chinese legends. In this study, anatomical structure of the goldfish dragon eye was compared with that of the common eye, and a stretching of the retina was observed in the enlarged dragon eye. Moreover, the homeobox-containing transcription factor Six3 cDNAs were cloned from the two types of goldfish, and the expression patterns were analyzed in both normal eye and dragon eye goldfish. No amino acid sequence differences were observed between the two deduced peptides, and the expression pattern of Six3 protein in dragon eye is quite similar to common eye during embryogenesis, but from 2 days after hatching, ectopic Six3 expression began to occur in the dragon eye, especially in the outer nuclear layer cells. With eye development, more predominant Six3 distribution was detected in the outer nuclear layer cells of dragon eye than that of normal eye, and fewer cell-layers in outer nuclear layer were observed in dragon eye retina than in normal eye retina. The highlight of this study is that higher Six3 expression occurs in dragon eye goldfish than in normal eye goldfish during retinal development of larvae.
Non-mydriatic video ophthalmoscope to measure fast temporal changes of the human retina
NASA Astrophysics Data System (ADS)
Tornow, Ralf P.; Kolář, Radim; Odstrčilík, Jan
2015-07-01
The analysis of fast temporal changes of the human retina can be used to get insight to normal physiological behavior and to detect pathological deviations. This can be important for the early detection of glaucoma and other eye diseases. We developed a small, lightweight, USB powered video ophthalmoscope that allows taking video sequences of the human retina with at least 25 frames per second without dilating the pupil. Short sequences (about 10 s) of the optic nerve head (20° x 15°) are recorded from subjects and registered offline using two-stage process (phase correlation and Lucas-Kanade approach) to compensate for eye movements. From registered video sequences, different parameters can be calculated. Two applications are described here: measurement of (i) cardiac cycle induced pulsatile reflection changes and (ii) eye movements and fixation pattern. Cardiac cycle induced pulsatile reflection changes are caused by changing blood volume in the retina. Waveform and pulse parameters like amplitude and rise time can be measured in any selected areas within the retinal image. Fixation pattern ΔY(ΔX) can be assessed from eye movements during video acquisition. The eye movements ΔX[t], ΔY[t] are derived from image registration results with high temporal (40 ms) and spatial (1,86 arcmin) resolution. Parameters of pulsatile reflection changes and fixation pattern can be affected in beginning glaucoma and the method described here may support early detection of glaucoma and other eye disease.
Modification of visual function by early visual experience.
Blakemore, C
1976-07-01
Physiological experiments, involving recording from the visual cortex in young kittens and monkeys, have given new insight into human developmental disorders. In the visual cortex of normal cats and monkeys most neurones are selectively sensitive to the orientation of moving edges and they receive very similar signals from both eyes. Even in very young kittens without visual experience, most neurones are binocularly driven and a small proportion of them are genuinely orientation selective. There is no passive maturation of the system in the absence of visual experience, but even very brief exposure to patterned images produces rapid emergence of the adult organization. These results are compared to observations on humans who have "recovered" from early blindness. Covering one eye in a kitten or a monkey, during a sensitive period early in life, produces a virtually complete loss of input from that eye in the cortex. These results can be correlated with the production of "stimulus deprivation amblyopia" in infants who have had one eye patched. Induction of a strabismus causes a loss of binocularity in the visual cortex, and in humans it leads to a loss of stereoscopic vision and binocular fusion. Exposing kittens to lines of one orientation modifies the preferred orientations of cortical cells and there is an analogous "meridional amblyopia" in astigmatic humans. The existence of a sensitive period in human vision is discussed, as well as the possibility of designing remedial and preventive treatments for human developmental disorders.
Topography and Higher Order Corneal Aberrations of the Fellow Eye in Unilateral Keratoconus.
Aksoy, Sibel; Akkaya, Sezen; Özkurt, Yelda; Kurna, Sevda; Açıkalın, Banu; Şengör, Tomris
2017-10-01
Comparison of topography and corneal higher order aberrations (HOA) data of fellow normal eyes of unilateral keratoconus patients with keratoconus eyes and control group. The records of 196 patients with keratoconus were reviewed. Twenty patients were identified as unilateral keratoconus. The best corrected visual acuity (BCVA), topography and aberration data of the unilateral keratoconus patients' normal eyes were compared with their contralateral keratoconus eyes and with control group eyes. For statistical analysis, flat and steep keratometry values, average corneal power, cylindrical power, surface regularity index (SRI), surface asymmetry index (SAI), inferior-superior ratio (I-S), keratoconus prediction index, and elevation-depression power (EDP) and diameter (EDD) topography indices were selected. Mean age of the unilateral keratoconus patients was 26.05±4.73 years and that of the control group was 23.6±8.53 years (p>0.05). There was no statistical difference in BCVA between normal and control eyes (p=0.108), whereas BCVA values were significantly lower in eyes with keratoconus (p=0.001). Comparison of quantitative topographic indices between the groups showed that all indices except the I-S ratio were significantly higher in the normal group than in the control group (p<0.05). The most obvious differences were in the SRI, SAI, EDP, and EDD values. All topographic indices were higher in the keratoconus eyes compared to the normal fellow eyes. There was no difference between normal eyes and the control group in terms of spherical aberration, while coma, trefoil, irregular astigmatism, and total HOA values were higher in the normal eyes of unilateral keratoconus patients (p<0.05). All HOA values were higher in keratoconus eyes than in the control group. According to our study, SRI, SAI, EDP, EDD values, and HOA other than spherical aberration were higher in the clinically and topographically normal fellow eyes of unilateral keratoconus patients when compared to a control group. This finding may be due to the mild asymmetric and morphologic changes in the subclinical stage of keratoconus leading to deterioration in the indicators of corneal irregularity and elevation changes. Therefore, these eyes may be exhibiting the early form of the disease.
Colitz, Carmen M H; Walsh, Michael T; McCulloch, Stephen D
2016-03-01
Cetaceans in the wild and under human care develop a variety of ocular lesions. Although they have echolocation, cetacean species have good sight, making ocular health an important part of overall health care. The cornea is the primary site of abnormalities in both populations. Typical lesions of cetaceans under human care are characterized in this retrospective review of cases. One hundred eighty animals (n = 360 eyes) were chosen from the author's ophthalmologic examination reports from different geographic areas; they included Atlantic bottlenose dolphins (Tursiops truncatus), Pacific bottle nose dolphins (Tursiopstruncatus gilli), Indopacific bottlenose dolphins (Steno bredanensis), Indopacific humpback dolphins (Sousa chinensis), and roughtooth dolphins (Steno bredanensis). These animals were examined at least once, although most were examined numerous times over many years; lesions were categorized and are described. Seventy-seven eyes from 47 animals were normal. Medial keratopathy was the most common lesion and identified in 180 eyes from 97 animals, with 83 affected bilaterally. Horizontal keratopathy was identified in 69 eyes from 41 animals, with 28 affected bilaterally. Axial keratopathy and nonspecific axial opacities were identified in 67 eyes from 44 animals, with 21 affected bilaterally. Seventy-eight eyes from 50 animals, with 28 affected bilaterally, had more than one type of corneal lesion. Cataracts were identified in 32 eyes from 19 animals, with 13 affected bilaterally. Traumatic injuries were also common and involved eyelids and cornea. Sixteen eyes from 11 animals were blind; five dolphins were blind bilaterally due to phthisis bulbi secondary to corneal perforation or severe trauma. None of the diseases had a sex predisposition; however, medial keratopathy was significantly more common as a bilateral presentation than as a unilateral presentation. Cetaceans under human care with impaired sight can use echolocation; however, ocular health should definitely be a priority in their overall health plan.
Peripapillary Pachychoroid in Nonarteritic Anterior Ischemic Optic Neuropathy
Nagia, Lina; Huisingh, Carrie; Johnstone, John; Kline, Lanning B.; Clark, Mark; Girard, Michael J. A.; Mari, Jean Martial; Girkin, Christopher A.
2016-01-01
Purpose This study examined the peripapillary choroidal thickness (PCT) in nonarteritic ischemic optic neuropathy (NAION) in comparison to contralateral eyes and normal eyes. Methods We used enhanced depth imaging spectral-domain optical coherence tomography to image the optic nerve head of 20 NAION, 10 contralateral eyes, and 102 normal eyes. Following compensation, the scans were manually delineated to identify relevant surfaces including Bruch's membrane opening (BMO), Bruch's membrane, and anterior sclera. The PCT was defined as the measurement between Bruch's membrane and the anterior sclera and was measured at increasing distance from BMO. Models adjusted for age, BMO area, and axial length were used to compare the mean PCT between NAION and normal eyes, and contralateral eyes and normal eyes. Paired t-tests were used to compare the PCT between NAION and contralateral eyes. Results The mean PCT was thicker in NAION and contralateral eyes when compared with normal eyes at all distances from BMO (P < 0.001). The PCT was not significantly thicker in contralateral eyes when compared with affected NAION eyes. Choroidal thickness was thinnest in the inferior quadrant in all eyes regardless of the group. Conclusions Increased peripapillary choroidal thickness was noted in both NAION and contralateral eyes. The thicker choroid may be an associated feature or a result of the disorder. Although further longitudinal study is required to determine causation, these findings may suggest that a thickened peripapillary choroid may be a component of the disk-at-risk clinical phenotype. PMID:27583829
Development of infrared thermal imager for dry eye diagnosis
NASA Astrophysics Data System (ADS)
Chiang, Huihua Kenny; Chen, Chih Yen; Cheng, Hung You; Chen, Ko-Hua; Chang, David O.
2006-08-01
This study aims at the development of non-contact dry eye diagnosis based on an infrared thermal imager system, which was used to measure the cooling of the ocular surface temperature of normal and dry eye patients. A total of 108 subjects were measured, including 26 normal and 82 dry eye patients. We have observed that the dry eye patients have a fast cooling of the ocular surface temperature than the normal control group. We have developed a simplified algorithm for calculating the temperature decay constant of the ocular surface for discriminating between normal and dry eye. This study shows the diagnostic of dry eye syndrome by the infrared thermal imager system has reached a sensitivity of 79.3%, a specificity of 75%, and the area under the ROC curve 0.841. The infrared thermal imager system has a great potential to be developed for dry eye screening with the advantages of non-contact, fast, and convenient implementation.
Left-right asymmetry of the Maxwell spot centroids in adults without and with dyslexia.
Le Floch, Albert; Ropars, Guy
2017-10-25
In human vision, the brain has to select one view of the world from our two eyes. However, the existence of a clear anatomical asymmetry providing an initial imbalance for normal neural development is still not understood. Using a so-called foveascope, we found that for a cohort of 30 normal adults, the two blue cone-free areas at the centre of the foveas are asymmetrical. The noise-stimulated afterimage dominant eye introduced here corresponds to the circular blue cone-free area, while the non-dominant eye corresponds to the diffuse and irregular elliptical outline. By contrast, we found that this asymmetry is absent or frustrated in a similar cohort of 30 adults with normal ocular status, but with dyslexia, i.e. with visual and phonological deficits. In this case, our results show that the two Maxwell centroid outlines are both circular but lead to an undetermined afterimage dominance with a coexistence of primary and mirror images. The interplay between the lack of asymmetry and the development in the neural maturation of the brain pathways suggests new implications in both fundamental and biomedical sciences. © 2017 The Author(s).
Von Zup, M; Lassaline, M; Kass, P H; Miller, P E; Thomasy, S M
2017-11-01
Brimonidine is an α 2 -adrenergic agonist that decreases aqueous humour production and may increase uveoscleral outflow. It has not been evaluated in normal or glaucomatous equine eyes. To evaluate the efficacy and safety of brimonidine in lowering intraocular pressure (IOP), alone and in conjunction with timolol, as a treatment for equine glaucoma by comparing IOP in normal equine eyes treated with brimonidine and brimonidine-timolol, respectively, with IOP in control eyes. A balanced crossover design with 16 horses receiving one of two treatments, brimonidine and brimonidine-timolol, during each of two 10-day study phases, was used. Four horses were randomly assigned to each of four combinations of treated eye (right or left) and drug order within the two 10-day study phases (brimonidine first or brimonidine-timolol first). Pupil size and conjunctival hyperaemia were assessed twice per day and IOP was measured three times per day using rebound tonometry in both eyes of 16 normal horses throughout two 10-day study periods (brimonidine and brimonidine-timolol) separated by an 18-day washout period. One eye of each horse was treated with brimonidine or brimonidine-timolol and the opposite eye was treated with balanced salt solution (BSS). There were no adverse effects and no significant changes in pupil size in normal equine eyes treated with brimonidine or brimonidine-timolol. Average IOP in normal equine eyes treated with brimonidine (25.6 mmHg) was statistically higher than in eyes treated with brimonidine-timolol (24.6 mmHg) or BSS (24.5 mmHg). However, IOP differences were of ≤1 mmHg and thus not clinically important. Horses with normal eyes may not be as sensitive to the IOP-lowering effects of treatment as horses with glaucoma. Brimonidine and brimonidine-timolol are well tolerated in normal horses but do not decrease IOP. © 2017 EVJ Ltd.
Ham, Bryan M.; Cole, Richard B.; Jacob, Jean T.
2008-01-01
Purpose To identify and compare the phosphorylated lipids in normal and dry eye rabbit tears using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS). Methods MALDI-TOF MS studies were performed on tear samples from normal and dry eyes of female New Zealand White rabbits. Experimental dry eye was induced by complete removal of the main and accessory lacrimal glands and nictitating membranes. A solid ionic crystal MALDI matrix of paranitroaniline and butyric acid was used to enhance the mass spectral responses of the phospholipids. In addition, a novel lipid isolation, preconcentration, and clean-up method using pipettes containing immobilized metal ion affinity chromatography (IMAC) medium was used. Results The polar phospholipids present in the normal and dry eye rabbit tears showed both similarities and differences. Species related to platelet-activating factor (PAF) and/or lysophosphatidylcholine (lyso-PC), phosphatidylcholine (PC), and sphingomyelin (SM) were found in both the normal and dry eye rabbit tears. However, the number of types and the concentrations of SM molecules were markedly greater in the dry eye tears than in the normal tears. In addition, phosphatidylserine (PS) species that were readily detectable in dry eye tears were not found in normal tears. Conclusions The combination of immobilized metal ion affinity chromatography and the solid ionic crystal matrix for MALDI enabled the detection and study of phosphorylated lipids in the tears. Specific differences between phospholipid levels in normal and dry eye tears were observable with this methodology. The appearance of various SM species only in the dry eye tears may provide markers for this disease state in the future. PMID:16877399
Collery, Ross F.; Veth, Kerry N.; Dubis, Adam M.; Carroll, Joseph; Link, Brian A.
2014-01-01
Refractive errors in vision can be caused by aberrant axial length of the eye, irregular corneal shape, or lens abnormalities. Causes of eye length overgrowth include multiple genetic loci, and visual parameters. We evaluate zebrafish as a potential animal model for studies of the genetic, cellular, and signaling basis of emmetropization and myopia. Axial length and other eye dimensions of zebrafish were measured using spectral domain-optical coherence tomography (SD-OCT). We used ocular lens and body metrics to normalize and compare eye size and relative refractive error (difference between observed retinal radial length and controls) in wild-type and lrp2 zebrafish. Zebrafish were dark-reared to assess effects of visual deprivation on eye size. Two relative measurements, ocular axial length to body length and axial length to lens diameter, were found to accurately normalize comparisons of eye sizes between different sized fish (R2 = 0.9548, R2 = 0.9921). Ray-traced focal lengths of wild-type zebrafish lenses were equal to their retinal radii, while lrp2 eyes had longer retinal radii than focal lengths. Both genetic mutation (lrp2) and environmental manipulation (dark-rearing) caused elongated eye axes. lrp2 mutants had relative refractive errors of −0.327 compared to wild-types, and dark-reared wild-type fish had relative refractive errors of −0.132 compared to light-reared siblings. Therefore, zebrafish eye anatomy (axial length, lens radius, retinal radius) can be rapidly and accurately measured by SD-OCT, facilitating longitudinal studies of regulated eye growth and emmetropization. Specifically, genes homologous to human myopia candidates may be modified, inactivated or overexpressed in zebrafish, and myopia-sensitizing conditions used to probe gene-environment interactions. Our studies provide foundation for such investigations into genetic contributions that control eye size and impact refractive errors. PMID:25334040
Monocular oral reading after treatment of dense congenital unilateral cataract
Birch, Eileen E.; Cheng, Christina; Christina, V; Stager, David R.
2010-01-01
Background Good long-term visual acuity outcomes for children with dense congenital unilateral cataracts have been reported following early surgery and good compliance with postoperative amblyopia therapy. However, treated eyes rarely achieve normal visual acuity and there has been no formal evaluation of the utility of the treated eye for reading. Methods Eighteen children previously treated for dense congenital unilateral cataract were tested monocularly with the Gray Oral Reading Test, 4th edition (GORT-4) at 7 to 13 years of age using two passages for each eye, one at grade level and one at +1 above grade level. In addition, right eyes of 55 normal children age 7 to 13 served as a control group. The GORT-4 assesses reading rate, accuracy, fluency, and comprehension. Results Visual acuity of treated eyes ranged from 0.1 to 2.0 logMAR and of fellow eyes from −0.1 to 0.2 logMAR. Treated eyes scored significantly lower than fellow and normal control eyes on all scales at grade level and at +1 above grade level. Monocular reading rate, accuracy, fluency, and comprehension were correlated with visual acuity of treated eyes (rs = −0.575 to −0.875, p < 0.005). Treated eyes with 0.1-0.3 logMAR visual acuity did not differ from fellow or normal control eyes in rate, accuracy, fluency, or comprehension when reading at grade level or at +1 above grade level. Fellow eyes did not differ from normal controls on any reading scale. Conclusions Excellent visual acuity outcomes following treatment of dense congenital unilateral cataracts are associated with normal reading ability of the treated eye in school-age children. PMID:20603057
Estimating outflow facility through pressure dependent pathways of the human eye
Gardiner, Bruce S.
2017-01-01
We develop and test a new theory for pressure dependent outflow from the eye. The theory comprises three main parameters: (i) a constant hydraulic conductivity, (ii) an exponential decay constant and (iii) a no-flow intraocular pressure, from which the total pressure dependent outflow, average outflow facilities and local outflow facilities for the whole eye may be evaluated. We use a new notation to specify precisely the meaning of model parameters and so model outputs. Drawing on a range of published data, we apply the theory to animal eyes, enucleated eyes and in vivo human eyes, and demonstrate how to evaluate model parameters. It is shown that the theory can fit high quality experimental data remarkably well. The new theory predicts that outflow facilities and total pressure dependent outflow for the whole eye are more than twice as large as estimates based on the Goldman equation and fluorometric analysis of anterior aqueous outflow. It appears likely that this discrepancy can be largely explained by pseudofacility and aqueous flow through the retinal pigmented epithelium, while any residual discrepancy may be due to pathological processes in aged eyes. The model predicts that if the hydraulic conductivity is too small, or the exponential decay constant is too large, then intraocular eye pressure may become unstable when subjected to normal circadian changes in aqueous production. The model also predicts relationships between variables that may be helpful when planning future experiments, and the model generates many novel testable hypotheses. With additional research, the analysis described here may find application in the differential diagnosis, prognosis and monitoring of glaucoma. PMID:29261696
Human Stereopsis is not Limited by the Optics of the Well-focused Eye
Vlaskamp, Björn N.S.; Yoon, Geunyoung; Banks, Martin S.
2011-01-01
Human stereopsis—the perception of depth from differences in the two eyes’ images—is very precise: Image differences smaller than a single photoreceptor can be converted into a perceived difference in depth. To better understand what determines this precision, we examined how the eyes’ optics affects stereo resolution. We did this by comparing performance with normal, well-focused optics and with optics improved by eliminating chromatic aberration and correcting higher-order aberrations. We first measured luminance contrast sensitivity in both eyes and showed that we had indeed improved optical quality significantly. We then measured stereo resolution in two ways: by finding the finest corrugation in depth that one can perceive, and by finding the smallest disparity one can perceive as different from zero. Our optical manipulation had no effect on stereo performance. We checked this by redoing the experiments at low contrast and again found no effect of improving optical quality. Thus, the resolution of human stereopsis is not limited by the optics of the well-focused eye. We discuss the implications of this remarkable finding. PMID:21734272
A scalable and deformable stylized model of the adult human eye for radiation dose assessment
NASA Astrophysics Data System (ADS)
El Basha, Daniel; Furuta, Takuya; Iyer, Siva S. R.; Bolch, Wesley E.
2018-05-01
With recent changes in the recommended annual limit on eye lens exposures to ionizing radiation, there is considerable interest in predictive computational dosimetry models of the human eye and its various ocular structures including the crystalline lens, ciliary body, cornea, retina, optic nerve, and central retinal artery. Computational eye models to date have been constructed as stylized models, high-resolution voxel models, and polygon mesh models. Their common feature, however, is that they are typically constructed of nominal size and of a roughly spherical shape associated with the emmetropic eye. In this study, we present a geometric eye model that is both scalable (allowing for changes in eye size) and deformable (allowing for changes in eye shape), and that is suitable for use in radiation transport studies of ocular exposures and radiation treatments of eye disease. The model allows continuous and variable changes in eye size (axial lengths from 20 to 26 mm) and eye shape (diopters from ‑12 to +6). As an explanatory example of its use, five models (emmetropic eyes of small, average, and large size, as well as average size eyes of ‑12D and +6D) were constructed and subjected to normally incident beams of monoenergetic electrons and photons, with resultant energy-dependent dose coefficients presented for both anterior and posterior eye structures. Electron dose coefficients were found to vary with changes to both eye size and shape for the posterior eye structures, while their values for the crystalline lens were found to be sensitive to changes in only eye size. No dependence upon eye size or eye shape was found for photon dose coefficients at energies below 2 MeV. Future applications of the model can include more extensive tabulations of dose coefficients to all ocular structures (not only the lens) as a function of eye size and shape, as well as the assessment of x-ray therapies for ocular disease for patients with non-emmetropic eyes.
Fang, Yi-Chin; Wu, Bo-Wen
2008-12-01
Thermal imaging is an important technology in both national defense and the private sector. An advantage of thermal imaging is its ability to be deployed while fully engaged in duties, not limited by weather or the brightness of indoor or outdoor conditions. However, in an outdoor environment, many factors, including atmospheric decay, target shape, great distance, fog, temperature out of range and diffraction limits can lead to bad image formation, which directly affects the accuracy of object recognition. The visual characteristics of the human eye mean that it has a much better capacity for picture recognition under normal conditions than artificial intelligence does. However, conditions of interference significantly reduce this capacity for picture recognition for instance, fatigue impairs human eyesight. Hence, psychological and physiological factors can affect the result when the human eye is adopted to measure MRTD (minimum resolvable temperature difference) and MRCTD (minimum resolvable circle temperature difference). This study explores thermal imaging recognition, and presents a method for effectively choosing the characteristic values and processing the images fully. Neural network technology is successfully applied to recognize thermal imaging and predict MRTD and MRCTD (Appendix A), exceeding thermal imaging recognition under fatigue and the limits of the human eye.
The Brainstem Switch for Gaze Shifts in Humans
2001-10-25
Page 1 of 4 THE BRAINSTEM SWITCH FOR GAZE SHIFTS IN HUMANS A. N. Kumar1, R. J. Leigh1,2, S. Ramat3 Department of 1Biomedical Engineering, Case...omnipause neurons during gaze shifts. Using the scleral search coil technique, eye movements were measured in seven normal subjects, as they made...voluntary, disjunctive gaze shifts comprising saccades and vergence movements. Conjugate oscillations of small amplitude and high frequency were identified
Barteselli, G; Gomez, M L; Doede, A L; Chhablani, J; Gutstein, W; Bartsch, D-U; Dustin, L; Azen, S P; Freeman, W R
2014-10-01
To evaluate visual function variations in eyes with age-related macular degeneration (AMD) compared to normal eyes under different light/contrast conditions using a time-dependent visual acuity testing instrument, the Central Vision Analyzer (CVA). Overall, 37 AMD eyes and 35 normal eyes were consecutively tested with the CVA after assessing best-corrected visual acuity (BCVA) using ETDRS charts. The CVA established visual thresholds for three mesopic environments (M1 (high contrast), M2 (medium contrast), and M3 (low contrast)) and three backlight-glare environments (G1 (high contrast, equivalent to ETDRS), G2 (medium contrast), and G3 (low contrast)) under timed conditions. Vision drop across environments was calculated, and repeatability of visual scores was determined. BCVA significantly reduced with decreasing contrast in all eyes. M1 scores for BCVA were greater than M2 and M3 (P<0.001); G1 scores were greater than G2 and G3 (P<0.01). BCVA dropped more in AMD eyes than in normal eyes between M1 and M2 (P=0.002) and between M1 and M3 (P=0.003). In AMD eyes, BCVA was better using ETDRS charts compared to G1 (P<0.001). The drop in visual function between ETDRS and G1 was greater in AMD eyes compared to normal eyes (P=0.004). Standard deviations of test-retest ranged from 0.100 to 0.139 logMAR. The CVA allowed analysis of the visual complaints that AMD patients experience with different lighting/contrast time-dependent conditions. BCVA changed significantly under different lighting/contrast conditions in all eyes, however, AMD eyes were more affected by contrast reduction than normal eyes. In AMD eyes, timed conditions using the CVA led to worse BCVA compared to non-timed ETDRS charts.
Villegas, Eloy A; Artal, Pablo
2003-02-01
To measure the wavefront aberration at different locations in progressive-power lenses (PPL's) isolated and in situ (PPL's plus eye). A Hartmann-Shack wavefront sensor was used to measure progressive-power lenses and human eyes either independently or in combination. In each selected zone, the lens was placed and tilted accordingly to simulate natural viewing conditions. We measured 21 relevant locations across an isolated PPL (plano lens of power addition of 2 D). In six of the locations, the wavefront aberration of the eye plus PPL were obtained in two ways: (1) by direct measurement of the system and (2) by adding the individual wavefront aberrations of the eye and the lens for each appropriate zone. In every case, we obtained the wavefront aberration as Zernike polynomials expansions, the root mean square error, the point-spread function, and the Strehl ratio. Along the corridor of the PPL, third-order coma and trefoil, and astigmatism were the dominant aberrations. In areas of the PPL outside the corridor, astigmatism increased, whereas other aberrations remained similar to the lens center. Small differences were found between the direct and calculated methods used to obtain the wavefront aberration of the eye with the lens, and the possible sources of errors were discussed. In some lenses zones, the aberrations of the lens may be compensated by the particular aberrations of the eye, yielding improved optical performance over that present in the lens alone. We designed and built a wavefront sensor to perform spatially resolved aberration measurements in ophthalmic lenses, in particular in PPL's, either isolated or in combination with the eye. The aberrations appearing in the PPL were compared with those in normal aged eyes.
Wong, Bernice H.; Chan, Jia Pei; Cazenave-Gassiot, Amaury; Poh, Rebecca W.; Foo, Juat Chin; Galam, Dwight L. A.; Ghosh, Sujoy; Nguyen, Long N.; Barathi, Veluchamy A.; Yeo, Sia W.; Luu, Chi D.; Wenk, Markus R.; Silver, David L.
2016-01-01
Eye photoreceptor membrane discs in outer rod segments are highly enriched in the visual pigment rhodopsin and the ω-3 fatty acid docosahexaenoic acid (DHA). The eye acquires DHA from blood, but transporters for DHA uptake across the blood-retinal barrier or retinal pigment epithelium have not been identified. Mfsd2a is a newly described sodium-dependent lysophosphatidylcholine (LPC) symporter expressed at the blood-brain barrier that transports LPCs containing DHA and other long-chain fatty acids. LPC transport via Mfsd2a has been shown to be necessary for human brain growth. Here we demonstrate that Mfsd2a is highly expressed in retinal pigment epithelium in embryonic eye, before the development of photoreceptors, and is the primary site of Mfsd2a expression in the eye. Eyes from whole body Mfsd2a-deficient (KO) mice, but not endothelium-specific Mfsd2a-deficient mice, were DHA-deficient and had significantly reduced LPC/DHA transport in vivo. Fluorescein angiography indicated normal blood-retinal barrier function. Histological and electron microscopic analysis indicated that Mfsd2a KO mice exhibited a specific reduction in outer rod segment length, disorganized outer rod segment discs, and mislocalization of and reduction in rhodopsin early in postnatal development without loss of photoreceptors. Minor photoreceptor cell loss occurred in adult Mfsd2a KO mice, but electroretinography indicated visual function was normal. The developing eyes of Mfsd2a KO mice had activated microglia and up-regulation of lipogenic and cholesterogenic genes, likely adaptations to loss of LPC transport. These findings identify LPC transport via Mfsd2a as an important pathway for DHA uptake in eye and for development of photoreceptor membrane discs. PMID:27008858
Kwon, Junki; Choi, Jaewan; Shin, Joong Won; Lee, Jiyun; Kook, Michael S
2017-12-01
To assess the diagnostic ability of foveal avascular zone (FAZ) parameters to discriminate glaucomatous eyes with visual field defects (VFDs) in different locations (central vs. peripheral) from normal eyes. Totally, 125 participants were separated into 3 groups: normal (n=45), glaucoma with peripheral VFD (PVFD, n=45), and glaucoma with central VFD (CVFD, n=35). The FAZ area, perimeter, and circularity and parafoveal vessel density were calculated from optical coherence tomography angiography images. The diagnostic ability of the FAZ parameters and other structural parameters was determined according to glaucomatous VFD location. Associations between the FAZ parameters and central visual function were evaluated. A larger FAZ area and longer FAZ perimeter were observed in the CVFD group than in the PVFD and normal groups. The FAZ area, perimeter, and circularity were better in differentiating glaucomatous eyes with CVFDs from normal eyes [areas under the receiver operating characteristic curves (AUC), 0.78 to 0.88] than in differentiating PVFDs from normal eyes (AUC, 0.51 to 0.64). The FAZ perimeter had a similar AUC value to the circumpapillary retinal nerve fiber layer and macular ganglion cell-inner plexiform layer thickness for differentiating eyes with CVFDs from normal eyes (all P>0.05, the DeLong test). The FAZ area was significantly correlated with central visual function (β=-112.7, P=0.035, multivariate linear regression). The FAZ perimeter had good diagnostic capability in differentiating glaucomatous eyes with CVFDs from normal eyes, and may be a potential diagnostic biomarker for detecting glaucomatous patients with CVFDs.
Extraocular muscle function testing
... may result in double vision or rapid, uncontrolled eye movements . Normal Results Normal movement of the eyes in all directions. What Abnormal Results Mean Eye movement disorders may be due to abnormalities of the ...
Quantitative analysis of iris parameters in keratoconus patients using optical coherence tomography.
Bonfadini, Gustavo; Arora, Karun; Vianna, Lucas M; Campos, Mauro; Friedman, David; Muñoz, Beatriz; Jun, Albert S
2015-01-01
To investigate the relationship between quantitative iris parameters and the presence of keratoconus. Cross-sectional observational study that included 15 affected eyes of 15 patients with keratoconus and 26 eyes of 26 normal age- and sex-matched controls. Iris parameters (area, thickness, and pupil diameter) of affected and unaffected eyes were measured under standardized light and dark conditions using anterior segment optical coherence tomography (AS-OCT). To identify optimal iris thickness cutoff points to maximize the sensitivity and specificity when discriminating keratoconus eyes from normal eyes, the analysis included the use of receiver operating characteristic (ROC) curves. Iris thickness and area were lower in keratoconus eyes than in normal eyes. The mean thickness at the pupillary margin under both light and dark conditions was found to be the best parameter for discriminating normal patients from keratoconus patients. Diagnostic performance was assessed by the area under the ROC curve (AROC), which had a value of 0.8256 with 80.0% sensitivity and 84.6% specificity, using a cutoff of 0.4125 mm. The sensitivity increased to 86.7% when a cutoff of 0.4700 mm was used. In our sample, iris thickness was lower in keratoconus eyes than in normal eyes. These results suggest that tomographic parameters may provide novel adjunct approaches for keratoconus screening.
Diagnostic ability of macular ganglion cell-inner plexiform layer thickness in glaucoma suspects.
Xu, Xiaoyu; Xiao, Hui; Guo, Xinxing; Chen, Xiangxi; Hao, Linlin; Luo, Jingyi; Liu, Xing
2017-12-01
The purpose is to assess the diagnostic ability for early glaucoma of macular ganglion cell-inner plexiform layer (GCIPL) thickness in a Chinese population including glaucoma suspects.A total of 367 eyes with primary open-angle glaucoma (168 early glaucoma, 78 moderate glaucoma, and 121 advanced glaucoma), 52 eyes with ocular hypertension (OHT), 59 eyes with enlarged cup-to-disc ratio (C/D), and 225 normal eyes were included. GCIPL thickness (average, minimum, superotemporal, superior, superonasal, inferonasal, inferior, and inferotemporal), retinal nerve fiber layer (RNFL) thickness, and optic nerve head (ONH) parameters were measured using Cirrus high-definition optical coherence tomography (OCT) and compared. The diagnostic ability of OCT parameters was assessed by area under receiver operating characteristic curve (AUROC) in 3 distinguishing groups: normal eyes and eyes with early glaucoma, normal eyes and eyes with glaucoma regardless of disease stage, and nonglaucomatous eyes (normal eyes, eyes with OHT, and enlarged C/D) and early glaucomatous eyes.Glaucomatous eyes showed a significant reduction in GCIPL thickness compared with nonglaucomatous eyes. In all 3 distinguishing groups, best-performing parameters of GCIPL thickness, RNFL thickness, and ONH parameters were minimum GCIPL thickness (expressed in AUROC, 0.899, 0.952, and 0.900, respectively), average RNFL thickness (0.904, 0.953, and 0.892, respectively), and rim area (0.861, 0.925, and 0.824, respectively). There was no statistical significance of AUROC between minimum GCIPL thickness and average RNFL thickness (all P > .05).GCIPL thickness could discriminate early glaucoma from normal and glaucoma suspects with good sensitivity and specificity. The glaucoma diagnostic ability of GCIPL thickness was comparable to that of RNFL thickness. Copyright © 2017 The Authors. Published by Wolters Kluwer Health, Inc. All rights reserved.
Asymmetric Dichoptic Masking in Visual Cortex of Amblyopic Macaque Monkeys
Shooner, Christopher; Hallum, Luke E.; García-Marín, Virginia; Kiorpes, Lynne
2017-01-01
In amblyopia, abnormal visual experience leads to an extreme form of eye dominance, in which vision through the nondominant eye is degraded. A key aspect of this disorder is perceptual suppression: the image seen by the stronger eye often dominates during binocular viewing, blocking the image of the weaker eye from reaching awareness. Interocular suppression is the focus of ongoing work aimed at understanding and treating amblyopia, yet its physiological basis remains unknown. We measured binocular interactions in visual cortex of anesthetized amblyopic monkeys (female Macaca nemestrina), using 96-channel “Utah” arrays to record from populations of neurons in V1 and V2. In an experiment reported recently (Hallum et al., 2017), we found that reduced excitatory input from the amblyopic eye (AE) revealed a form of balanced binocular suppression that is unaltered in amblyopia. Here, we report on the modulation of the gain of excitatory signals from the AE by signals from its dominant fellow eye (FE). Using a dichoptic masking technique, we found that AE responses to grating stimuli were attenuated by the presentation of a noise mask to the FE, as in a normal control animal. Responses to FE stimuli, by contrast, could not be masked from the AE. We conclude that a weakened ability of the amblyopic eye to modulate cortical response gain creates an imbalance of suppression that favors the dominant eye. SIGNIFICANCE STATEMENT In amblyopia, vision in one eye is impaired as a result of abnormal early visual experience. Behavioral observations in humans with amblyopia suggest that much of their visual loss is due to active suppression of their amblyopic eye. Here we describe experiments in which we studied binocular interactions in macaques with experimentally induced amblyopia. In normal monkeys, the gain of neuronal response to stimulation of one eye is modulated by contrast in the other eye, but in monkeys with amblyopia the balance of gain modulation is altered so that the weaker, amblyopic eye has little effect while the stronger fellow eye has a strong effect. This asymmetric suppression may be a key component of the perceptual losses in amblyopia. PMID:28760867
Asymmetric Dichoptic Masking in Visual Cortex of Amblyopic Macaque Monkeys.
Shooner, Christopher; Hallum, Luke E; Kumbhani, Romesh D; García-Marín, Virginia; Kelly, Jenna G; Majaj, Najib J; Movshon, J Anthony; Kiorpes, Lynne
2017-09-06
In amblyopia, abnormal visual experience leads to an extreme form of eye dominance, in which vision through the nondominant eye is degraded. A key aspect of this disorder is perceptual suppression: the image seen by the stronger eye often dominates during binocular viewing, blocking the image of the weaker eye from reaching awareness. Interocular suppression is the focus of ongoing work aimed at understanding and treating amblyopia, yet its physiological basis remains unknown. We measured binocular interactions in visual cortex of anesthetized amblyopic monkeys (female Macaca nemestrina ), using 96-channel "Utah" arrays to record from populations of neurons in V1 and V2. In an experiment reported recently (Hallum et al., 2017), we found that reduced excitatory input from the amblyopic eye (AE) revealed a form of balanced binocular suppression that is unaltered in amblyopia. Here, we report on the modulation of the gain of excitatory signals from the AE by signals from its dominant fellow eye (FE). Using a dichoptic masking technique, we found that AE responses to grating stimuli were attenuated by the presentation of a noise mask to the FE, as in a normal control animal. Responses to FE stimuli, by contrast, could not be masked from the AE. We conclude that a weakened ability of the amblyopic eye to modulate cortical response gain creates an imbalance of suppression that favors the dominant eye. SIGNIFICANCE STATEMENT In amblyopia, vision in one eye is impaired as a result of abnormal early visual experience. Behavioral observations in humans with amblyopia suggest that much of their visual loss is due to active suppression of their amblyopic eye. Here we describe experiments in which we studied binocular interactions in macaques with experimentally induced amblyopia. In normal monkeys, the gain of neuronal response to stimulation of one eye is modulated by contrast in the other eye, but in monkeys with amblyopia the balance of gain modulation is altered so that the weaker, amblyopic eye has little effect while the stronger fellow eye has a strong effect. This asymmetric suppression may be a key component of the perceptual losses in amblyopia. Copyright © 2017 the authors 0270-6474/17/378734-08$15.00/0.
Cavernous sinus syndrome in a Holstein bull.
Jacob, Sarah I; Drees, Randi; Pinkerton, Marie E; Bentley, Ellison M; Peek, Simon F
2015-03-01
A 13-month-old Holstein bull was presented for right-sided exophthalmos. Ophthalmologic examination noted that the animal was visual in both eyes, but that the right pupil was persistently dilated and very sluggish to constrict when stimulated with a bright light and that normal ocular motility was absent. Fundic examination of the right eye was normal as was a complete ophthalmologic examination of the left eye. Radiographs at presentation did not reveal the presence of sinusitis or other skull abnormalities. Initial treatment comprised intravenous antibiotics and anti-inflammatories for orbital inflammation over a 14-day period. There was no perceptible change in the appearance or neuro-ophthalmologic examination of the right eye during hospitalization. The animal was discharged to the owner's care, but 3 weeks later was found recumbent with unilateral strabismus of the left eye and a fixed right pupil. Due to the inability to rise and rapid deterioration, humane euthanasia was performed, and a full postmortem examination, preceded by a MRI, was performed that identified abscesses extending bilaterally through the round foramina obliterating the cavernous sinus region, as well as abscessation of the right mandible, right trigeminal neuritis, right-sided sinusitis, and right-sided otitis media. Cavernous sinus syndrome should be considered in cattle with a combination of exophthalmos and neuro-ophthalmologic abnormalities involving cranial nerves III, IV, V, and VI, whose branches are located within the cavernous sinus. © 2013 American College of Veterinary Ophthalmologists.
NASA Astrophysics Data System (ADS)
Iomdina, Elena N.; Goltsman, Gregory N.; Seliverstov, Sergey V.; Sianosyan, Alisa A.; Teplyakova, Kseniya O.; Rusova, Anastasia A.
2016-09-01
An adequate water balance (hydration extent) is one of the basic factors of normal eye function, including its external shells: the cornea and the sclera. Adequate control of corneal and scleral hydration is very important for early diagnosis of a variety of eye diseases, stating indications for and contraindications against keratorefractive surgeries and the choice of contact lens correction solutions. THz systems of creating images in reflected beams are likely to become ideal instruments of noninvasive control of corneal and scleral hydration degrees. This paper reports on the results of a study involving transmittance and reflectance spectra for the cornea and the sclera of rabbit and human eyes, as well as those of the rabbit eye, in the frequency range of 0.13 to 0.32 THz. The dependence of the reflectance coefficient of these tissues on water mass percentage content was determined. The experiments were performed on three corneas, three rabbit scleras, two rabbit eyes, and three human scleras. The preliminary results demonstrate that the proposed technique, based on the use of a continuous THz radiation, may be utilized to create a device for noninvasive control of corneal and scleral hydration, which has clear potential of broad practical application.
Gilaie-Dotan, Sharon; Doron, Ravid
2017-06-01
Visual categories are associated with eccentricity biases in high-order visual cortex: Faces and reading with foveally-biased regions, while common objects and space with mid- and peripherally-biased regions. As face perception and reading are among the most challenging human visual skills, and are often regarded as the peak achievements of a distributed neural network supporting common objects perception, it is unclear why objects, which also rely on foveal vision to be processed, are associated with mid-peripheral rather than with a foveal bias. Here, we studied BN, a 9 y.o. boy who has normal basic-level vision, abnormal (limited) oculomotor pursuit and saccades, and shows developmental object and contour integration deficits but with no indication of prosopagnosia. Although we cannot infer causation from the data presented here, we suggest that normal pursuit and saccades could be critical for the development of contour integration and object perception. While faces and perhaps reading, when fixated upon, take up a small portion of central visual field and require only small eye movements to be properly processed, common objects typically prevail in mid-peripheral visual field and rely on longer-distance voluntary eye movements as saccades to be brought to fixation. While retinal information feeds into early visual cortex in an eccentricity orderly manner, we hypothesize that propagation of non-foveal information to mid and high-order visual cortex critically relies on circuitry involving eye movements. Limited or atypical eye movements, as in the case of BN, may hinder normal information flow to mid-eccentricity biased high-order visual cortex, adversely affecting its development and consequently inducing visual perceptual deficits predominantly for categories associated with these regions. Copyright © 2017 Elsevier Ltd. All rights reserved.
Contact Lens Anterior Surface pH
1991-02-01
greenhouse effect and contact lenses, in Trans- 4. Nom MS: Tear fluid pH in normals, contact lens wearers, actions of the British Contact Lens...Invest 3. Fullard R), Carney LG: Diurnal variation in human tear en- Op/hdanmol Vis Sci 1978;17:810-813. ymes. Exp Eye Res 1984;38:15-26. 20. Efron N: The
NASA Astrophysics Data System (ADS)
Sugiyama, S.; Hong, Y.-J.; Kasaragod, D.; Makita, S.; Miura, M.; Ikuno, Y.; Yasuno, Y.
2016-03-01
Quantitative evaluation of optical properties of choroid and sclera are performed by multifunctional optical coherence tomography. Five normal eyes, five glaucoma eyes and one choroidal atrophy eye are examined. The refractive error was found to be correlated with choroidal birefringence, polarization uniformity, and flow in addition to scleral birefringence among normal eyes. The significant differences were observed between the normal and the glaucoma eyes, as for choroidal polarization uniformity, flow and scleral birefringence. An automatic segmentation algorithm of retinal pigment epithelium and chorioscleral interface based on multifunctional signals is also presented.
NASA Astrophysics Data System (ADS)
Poddar, Raju; Zawadzki, Robert J.; Cortés, Dennis E.; Mannis, Mark J.; Werner, John S.
2015-06-01
We present in vivo volumetric depth-resolved vasculature images of the anterior segment of the human eye acquired with phase-variance based motion contrast using a high-speed (100 kHz, 105 A-scans/s) swept source optical coherence tomography system (SSOCT). High phase stability SSOCT imaging was achieved by using a computationally efficient phase stabilization approach. The human corneo-scleral junction and sclera were imaged with swept source phase-variance optical coherence angiography and compared with slit lamp images from the same eyes of normal subjects. Different features of the rich vascular system in the conjunctiva and episclera were visualized and described. This system can be used as a potential tool for ophthalmological research to determine changes in the outflow system, which may be helpful for identification of abnormalities that lead to glaucoma.
Optical anisotropy of the human cornea determined with a polarizing microscope.
Bone, Richard A; Draper, Grenville
2007-12-01
We have investigated the optical anisotropy of the human cornea using a polarizing microscope normally used for optical mineralogy studies. The central part of the cornea was removed from 14 eyes (seven donors). With the sample placed on the microscope stage, we consistently observed hyperbolic isogyres characteristic of a negative biaxial material. The angle between the optic axes, generally similar in both eyes, ranged from 12 degrees to 40 degrees (mean+/-SD=31 degrees +/-8 degrees ). The optic axial plane always inclined downward in the nasal direction at 1 degrees -45 degrees below the horizontal (mean+/-SD=22+/-13 degrees ). The retardance produced by the corneas was estimated to be less than 200 nm. In conclusion, the human cornea possesses the anisotropy of a negative biaxial material. Both the angle between the optic axes and the retardance were fairly constant among the majority of samples, suggestive of uniformity in corneal structure.
The Charles F. Prentice Award Lecture 2005: optics of the human eye: progress and problems.
Charman, W Neil
2006-06-01
The history of measurements of ocular aberration is briefly reviewed and recent work using much-improved aberrometers and large samples of eyes is summarized. When on-axis, higher-order, monochromatic aberrations are averaged, undercorrected, positive, fourth-order spherical aberration dominates; other Zernike wavefront aberration coefficients have average values near zero. Individually, however, many eyes show substantial amounts of third-order and other fourth-order aberrations; the value of these varies idiosyncratically about zero. Most normal eyes show only small amounts of axial monochromatic aberration for photopic pupils up to around 3 mm; the limits to retinal image quality are then usually set by diffraction, uncorrected or imperfectly corrected spherocylindrical refractive error, accommodation error, and chromatic aberration. Longitudinal chromatic aberration varies very little across the population. With larger mesopic and scotopic pupils, monochromatic aberration plays a more important optical role, but overall visual performance is increasingly dominated by neural factors. Some remaining problems in measuring and modeling the eye's optical performance are discussed.
Wu, Wenjing; Wang, Yan; Xu, Lulu
2014-01-01
The aim of this meta-analysis is to evaluate the central corneal thickness (CCT) measurement differences between Pentacam (Oculus Inc., Germany) and Ultrasound Pachymetry (USP) in normal (unoperated eyes , myopic and astigmatic eyes without corneal disease or topographic irregularity), after laser in situ keratomileusis (LASIK) or photorefractive keratectomy (PRK), and keratoconic or keratoconus suspected eyes. We assess whether Pentacam and USP have similar CCT differences in normal, thinner corneas after LASIK or PRK procedures, and kerotoconic or keratoconus suspected eyes. Data sources, including PubMed, Medline, EMBASE, and Cochrane Central Registry of Controlled Trials on the Cochrane Library, were searched to find the relevant studies. Primary outcome measures were CCT measurement between Pentacam and USP. Three groups of eyes were analyzed: normal; LASIK or PRK eyes; and keratoconus suspected or keratoconic eyes. Nineteen studies describing 1,908 eyes were enrolled in the normal group. Pentacam results were 1.47 μm ,95 % confidence interval (CI) -2.32 to 5.27, higher than USP without statistically significant difference (P = 0.45). Nine studies with total 539 eyes were included in the corneas after LASIK or PRK. The mean difference in the CCT measurement with Pentacam and ultrasound pachymetry was 1.03 μm, with the 95 % CI -3.36 to 5.42, there was no statistically difference (P = 0.64). Four studies with a total of 185 eyes were included in the keratoconic eyes or keratoconus-suspect group, however,the mean difference was -6.33 μm (95 % CI -9.17 to-3.49), which was statistically different between Pentacam and ultrasound pachymetry in the CCT measurement (P < 0.0001). Pentacam offers similar CCT results to ultrasound pachymetry in normal eyes, thinner corneas after LASIK or PRK procedures. However, in keratoconic or keratoconus-suspect eyes, Pentacam slightly underestimates the central corneal thickness than does ultrasound pachymetry, which may result from the difficulty in fixation of keratoconic eyes, misalignment of Pentacam and the variation of ultrasonic velocity due to the histological deformation.
Norton, Thomas T.
2012-01-01
Purpose. During the development of, and recovery from, negative lens-induced myopia there is regulated remodeling of the scleral extracellular matrix (ECM) that controls the extensibility of the sclera. Difference gel electrophoresis (DIGE) was used to identify and categorize proteins whose levels are altered in this process. Methods. Two groups of five tree shrews started monocular lens wear 24 days after eye opening (days of visual experience [VE]). The lens-induced myopia (LIM) group wore a −5 D lens for 4 days. The recovery (REC) group wore a −5 D lens for 11 days and then recovered for 4 days. Two normal groups (28 and 39 days of VE; n = 5 each) were also examined, age-matched to each of the treatment groups. Refractive and A-scan measures confirmed the effect of the treatments. Scleral proteins were isolated and resolved by DIGE. Proteins that differed in abundance were identified by mass spectrometry. Ingenuity pathway analysis was used to investigate potential biological pathway interactions. Results. During normal development (28–39 days of VE), eight proteins decreased and one protein increased in relative abundance. LIM-treated eyes were myopic and longer than control eyes; LIM-control eyes were slightly myopic compared with 28N eyes, indicating a yoking effect. In both the LIM-treated and the LIM-control eyes, there was a general downregulation from normal of proteins involved in transcription, cell adhesion, and protein synthesis. Additional proteins involved in cell adhesion, actin cytoskeleton, transcriptional regulation, and ECM structural proteins differed in the LIM-treated eyes versus normal but did not differ in the control eyes versus normal. REC-treated eyes were recovering from the induced myopia. REC-control eye refractions were not significantly different from the 39N eyes, and few proteins differed from age-matched normal eyes. The balance of protein expression in the REC-treated eyes, compared with normal eyes and REC-control eyes, shifted toward upregulation or a return to normal levels of proteins involved in cell adhesion, cell division, cytoskeleton, and ECM structural proteins, including upregulation of several cytoskeleton-related proteins not affected during myopia development. Conclusions. The DIGE procedure revealed new proteins whose abundance is altered during myopia development and recovery. Many of these are involved in cell-matrix adhesions, cytoskeleton, and transcriptional regulation and extend our understanding of the remodeling that controls the extensibility of the sclera. Reductions in these proteins during minus lens wear may produce the increased scleral viscoelasticity that results in faster axial elongation. Recovery is not a mirror image of lens-induced myopia—many protein levels, decreased during LIM, returned to normal, or slightly above normal, and additional cytoskeleton proteins were upregulated. However, no single protein or pathway appeared to be responsible for the scleral changes during myopia development or recovery. PMID:22039233
NASA Technical Reports Server (NTRS)
Reschke, Millard F.; Somers, Jeffrey T.; Feiveson, Alan H.; Leigh, R. John; Wood, Scott J.; Paloski, William H.; Kornilova, Ludmila
2006-01-01
We studied the ability to hold the eyes in eccentric horizontal or vertical gaze angles in 68 normal humans, age range 19-56. Subjects attempted to sustain visual fixation of a briefly flashed target located 30 in the horizontal plane and 15 in the vertical plane in a dark environment. Conventionally, the ability to hold eccentric gaze is estimated by fitting centripetal eye drifts by exponential curves and calculating the time constant (t(sub c)) of these slow phases of gazeevoked nystagmus. Although the distribution of time-constant measurements (t(sub c)) in our normal subjects was extremely skewed due to occasional test runs that exhibited near-perfect stability (large t(sub c) values), we found that log10(tc) was approximately normally distributed within classes of target direction. Therefore, statistical estimation and inference on the effect of target direction was performed on values of z identical with log10t(sub c). Subjects showed considerable variation in their eyedrift performance over repeated trials; nonetheless, statistically significant differences emerged: values of tc were significantly higher for gaze elicited to targets in the horizontal plane than for the vertical plane (P less than 10(exp -5), suggesting eccentric gazeholding is more stable in the horizontal than in the vertical plane. Furthermore, centrifugal eye drifts were observed in 13.3, 16.0 and 55.6% of cases for horizontal, upgaze and downgaze tests, respectively. Fifth percentile values of the time constant were estimated to be 10.2 sec, 3.3 sec and 3.8 sec for horizontal, upward and downward gaze, respectively. The difference between horizontal and vertical gazeholding may be ascribed to separate components of the velocity position neural integrator for eye movements, and to differences in orbital mechanics. Our statistical method for representing the range of normal eccentric gaze stability can be readily applied in a clinical setting to patients who were exposed to environments that may have modified their central integrators and thus require monitoring. Patients with gaze-evoked nystagmus can be flagged by comparing to the above established normative criteria.
Extralenticular and lenticular aspects of accommodation and presbyopia in human versus monkey eyes.
Croft, Mary Ann; McDonald, Jared P; Katz, Alexander; Lin, Ting-Li; Lütjen-Drecoll, Elke; Kaufman, Paul L
2013-07-26
To determine if the accommodative forward movements of the vitreous zonule and lens equator occur in the human eye, as they do in the rhesus monkey eye; to investigate the connection between the vitreous zonule posterior insertion zone and the posterior lens equator; and to determine which components-muscle apex width, lens thickness, lens equator position, vitreous zonule, circumlental space, and/or other intraocular dimensions, including those stated in the objectives above-are most important in predicting accommodative amplitude and presbyopia. Accommodation was induced pharmacologically in 12 visually normal human subjects (ages 19-65 years) and by midbrain electrical stimulation in 11 rhesus monkeys (ages 6-27 years). Ultrasound biomicroscopy imaged the entire ciliary body, anterior and posterior lens surfaces, and the zonule. Relevant distances were measured in the resting and accommodated eyes. Stepwise regression analysis determined which variables were the most important predictors. The human vitreous zonule and lens equator move forward (anteriorly) during accommodation, and their movements decline with age, as in the monkey. Over all ages studied, age could explain accommodative amplitude, but not as well as accommodative lens thickening and resting muscle apex thickness did together. Accommodative change in distances between the vitreous zonule insertion zone and the posterior lens equator or muscle apex were important for predicting accommodative lens thickening. Our findings quantify the movements of the zonule and ciliary muscle during accommodation, and identify their age-related changes that could impact the optical change that occurs during accommodation and IOL function.
Ueki, Ryotaro; Maeda, Naoyuki; Fuchihata, Mutsumi; Asai, Tomoko; Koh, Shizuka; Fujimoto, Hisataka; Uematsu, Masafumi; Nishida, Kohji
2018-04-26
To investigate the corneal biomechanics in eyes with keratectasia following LASIK using a dynamic Scheimpflug analyzer. Case-Control study. The subjects in the study included 12 eyes with keratectasia after LASIK (KE), 24 eyes with keratoconus (KC), 17 eyes without keratectasia after LASIK (LASIK), and 34 eyes with normal corneas (Normal). Corneal biomechanics of the four groups were evaluated using a dynamic Scheimpflug analyzer. Compared with Normal (7.06 ± 0.54), the radius at the highest concavity (radius, mm) of LASIK (5.96 ± 0.76), KE (4.93 ± 0.61) and KC (5.39 ± 1.02) were significantly small. The Deflection Amplitude (HCDLA, mm) of Normal (0.94 ± 0.07) was significantly lower than those of KE (1.11 ± 0.10) and KC (1.06 ± 0.16), and was not significantly different from that of LASIK (0.98 ± 0.07). There were significant differences between LASIK and KE in radius and HCDLA (P < 0.05), whereas KE and KC had no differences in these parameters. Corneal biomechanical features evaluated using the dynamic Scheimpflug analyzer suggest that biomechanical properties in eyes with keratectasia, keratoconus, and LASIK are different from those of normal eyes. Although the biomechanics in eyes with keratectasia differs from that in eyes with LASIK, it is similar to that in eyes with keratoconus.
Wang, Xiu; Lu, Xiaoxiao; Yang, Jun; Wei, Ruihua; Yang, Liyuan; Zhao, Shaozhen; Wang, Xilian
2016-01-01
Purpose. This study aims to evaluate dry eye and ocular surface conditions of myopic teenagers by using questionnaire and clinical examinations. Methods. A total of 496 eyes from 248 myopic teenagers (7–18 years old) were studied. We administered Ocular Surface Disease Index (OSDI) questionnaire, slit-lamp examination, and Keratograph 5M. The patients were divided into 2 groups based on OSDI dry eye standard, and their ocular surfaces and meibomian gland conditions were evaluated. Results. The tear meniscus heights of the dry eye and normal groups were in normal range. Corneal fluorescein scores were significantly higher whereas noninvasive break-up time was dramatically shorter in the dry eye group than in the normal group. All three meibomian gland dysfunction parameters (i.e., meibomian gland orifice scores, meibomian gland secretion scores, and meibomian gland dropout scores) of the dry eye group were significantly higher than those of the normal group (P < 0.0001). Conclusions. The prevalence of dry eye in myopic teenagers is 18.95%. Meibomian gland dysfunction plays an important role in dry eye in myopic teenagers. The Keratograph 5M appears to provide an effective noninvasive method for assessing ocular surface situation of myopic teenagers. PMID:26881059
Cognitive processing of orientation discrimination in anisometropic amblyopia.
Wang, Jianglan; Zhao, Jiao; Wang, Shoujing; Gong, Rui; Zheng, Zhong; Liu, Longqian
2017-01-01
Cognition is very important in our daily life. However, amblyopia has abnormal visual cognition. Physiological changes of the brain during processes of cognition could be reflected with ERPs. So the purpose of this study was to investigate the speed and the capacity of resource allocation in visual cognitive processing in orientation discrimination task during monocular and binocular viewing conditions of amblyopia and normal control as well as the corresponding eyes of the two groups with ERPs. We also sought to investigate whether the speed and the capacity of resource allocation in visual cognitive processing vary with target stimuli at different spatial frequencies (3, 6 and 9 cpd) in amblyopia and normal control as well as between the corresponding eyes of the two groups. Fifteen mild to moderate anisometropic amblyopes and ten normal controls were recruited. Three-stimulus oddball paradigms of three different spatial frequency orientation discrimination tasks were used in monocular and binocular conditions in amblyopes and normal controls to elicit event-related potentials (ERPs). Accuracy (ACC), reaction time (RT), the latency of novelty P300 and P3b, and the amplitude of novelty P300 and P3b were measured. Results showed that RT was longer in the amblyopic eye than in both eyes of amblyopia and non-dominant eye in control. Novelty P300 amplitude was largest in the amblyopic eye, followed by the fellow eye, and smallest in both eyes of amblyopia. Novelty P300 amplitude was larger in the amblyopic eye than non-dominant eye and was larger in fellow eye than dominant eye. P3b latency was longer in the amblyopic eye than in the fellow eye, both eyes of amblyopia and non-dominant eye of control. P3b latency was not associated with RT in amblyopia. Neural responses of the amblyopic eye are abnormal at the middle and late stages of cognitive processing, indicating that the amblyopic eye needs to spend more time or integrate more resources to process the same visual task. Fellow eye and both eyes in amblyopia are slightly different from the dominant eye and both eyes in normal control at the middle and late stages of cognitive processing. Meanwhile, abnormal extents of amblyopic eye do not vary with three different spatial frequencies used in our study.
Cognitive processing of orientation discrimination in anisometropic amblyopia
Wang, Jianglan; Zhao, Jiao; Wang, Shoujing; Gong, Rui; Zheng, Zhong; Liu, Longqian
2017-01-01
Cognition is very important in our daily life. However, amblyopia has abnormal visual cognition. Physiological changes of the brain during processes of cognition could be reflected with ERPs. So the purpose of this study was to investigate the speed and the capacity of resource allocation in visual cognitive processing in orientation discrimination task during monocular and binocular viewing conditions of amblyopia and normal control as well as the corresponding eyes of the two groups with ERPs. We also sought to investigate whether the speed and the capacity of resource allocation in visual cognitive processing vary with target stimuli at different spatial frequencies (3, 6 and 9 cpd) in amblyopia and normal control as well as between the corresponding eyes of the two groups. Fifteen mild to moderate anisometropic amblyopes and ten normal controls were recruited. Three-stimulus oddball paradigms of three different spatial frequency orientation discrimination tasks were used in monocular and binocular conditions in amblyopes and normal controls to elicit event-related potentials (ERPs). Accuracy (ACC), reaction time (RT), the latency of novelty P300 and P3b, and the amplitude of novelty P300 and P3b were measured. Results showed that RT was longer in the amblyopic eye than in both eyes of amblyopia and non-dominant eye in control. Novelty P300 amplitude was largest in the amblyopic eye, followed by the fellow eye, and smallest in both eyes of amblyopia. Novelty P300 amplitude was larger in the amblyopic eye than non-dominant eye and was larger in fellow eye than dominant eye. P3b latency was longer in the amblyopic eye than in the fellow eye, both eyes of amblyopia and non-dominant eye of control. P3b latency was not associated with RT in amblyopia. Neural responses of the amblyopic eye are abnormal at the middle and late stages of cognitive processing, indicating that the amblyopic eye needs to spend more time or integrate more resources to process the same visual task. Fellow eye and both eyes in amblyopia are slightly different from the dominant eye and both eyes in normal control at the middle and late stages of cognitive processing. Meanwhile, abnormal extents of amblyopic eye do not vary with three different spatial frequencies used in our study. PMID:29023501
Noninvasive spectroscopic diagnosis of superficial ocular lesions and corneal infections
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mourant, J.R.; Bigio, I.J.; Johnson, T.
The potential of a rapid noninvasive diagnostic system to detect tissue abnormalities on the surface of the eye has been investigated. The optical scatter signal from lesions and normal areas on the conjunctival sclera of the human eye were measured in vivo. It is possible to distinguish nonpigmented pingueculas from other lesions. The ability of the system to detect malignancies could not be tested because none of the measured and biopsied lesions were malignant. Optical scatter and fluorescence spectra of bacterial and fungal suspensions, and corneal irritations were also collected. Both scattering and fluorescence show potential for diagnosing corneal infections.
Choroidal thickness in Chinese patients with non-arteritic anterior ischemic optic neuropathy.
Jiang, Libin; Chen, Lanlan; Qiu, Xiujuan; Jiang, Ran; Wang, Yaxing; Xu, Liang; Lai, Timothy Y Y
2016-08-31
Non-arteritic anterior ischemic optic neuropathy (NA-AION) is one of the most common types of ischemic optic neuropathy. Several recent studies suggested that abnormalities of choroidal thickness might be associated with NA-AION. The main objective of this case-control study was to evaluate whether choroidal thickness is an ocular risk factor for the development of NA-AION by evaluating the peripapillary and subfoveal choroidal thicknesses in affected Chinese patients. Forty-four Chinese patients with unilateral NA-AION were recruited and compared with 60 eyes of 60 normal age and refractive-error matched control subjects. Peripapillary and subfoveal choroidal thicknesses were measured by enhanced depth imaging optical coherence tomography. Choroidal thicknesses of eyes with NA-AION and unaffected fellow eyes were compared with normal controls. Choroidal thicknesses of NA-AION eyes with or without optic disc edema were also compared. The correlation between choroidal thickness and retinal nerve fiber layer (RNFL) thickness, logMAR best-corrected visual acuity (BCVA), and the mean deviation (MD) of Humphrey static perimetry in NA-AION eyes were analyzed. The peripapillary choroidal thicknesses at the nasal, nasal inferior and temporal inferior segments in NA-AION eyes with optic disc edema were significantly thicker compared with that of normal subjects (P < 0.05). There was no significant difference in the choroidal thicknesses between the unaffected fellow eyes of NA-AION patients and normal eyes of healthy controls; or between the NA-AION eyes with resolved optic disc edema and normal eyes (all P > 0.05). No significant correlation between choroidal thickness and RNFL thickness, logMAR BCVA and perimetry MD was found in eyes affected by NA-AION (all P > 0.05). Increase in peripapillary choroid thickness in some segments was found in NA-ION eyes with optic disc edema. However, our findings do not support the hypothesis that choroidal thickness is abnormal in Chinese patients with NA-AION compared with normal subjects with similar age and refractive error status.
McGinnigle, Samantha; Eperjesi, Frank; Naroo, Shehzad A
2014-04-01
To study the effects of ocular lubricants on higher order aberrations in normal and self-diagnosed dry eyes. Unpreserved hypromellose drops, Tears Again™ liposome spray and a combination of both were administered to the right eye of 24 normal and 24 dry eye subjects following classification according to a 5 point questionnaire. Total ocular higher order aberrations, coma, spherical aberration and Strehl ratios for higher order aberrations were measured using the Nidek OPD-Scan III (Nidek Technologies, Gamagori, Japan) at baseline, immediately after application and after 60 min. The aberration data were analyzed over a 5mm natural pupil using Zernike polynomials. Each intervention was assessed on a separate day and comfort levels were recorded before and after application. Corneal staining was assessed and product preference recorded after the final measurement for each intervention. Hypromellose drops caused an increase in total higher order aberrations (p=<0.01 in normal and dry eyes) and a reduction in Strehl ratio (normal eyes: p=<0.01, dry eyes p=0.01) immediately after instillation. There were no significant differences between normal and self-diagnosed dry eyes for response to intervention and no improvement in visual quality or reduction in higher order aberrations after 60 min. Differences in comfort levels failed to reach statistical significance. Combining treatments does not offer any benefit over individual treatments in self-diagnosed dry eyes and no individual intervention reached statistical significance. Symptomatic subjects with dry eye and no corneal staining reported an improvement in comfort after using lubricants. Copyright © 2013 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.
Time course of dichoptic masking in normals and suppression in amblyopes.
Zhou, Jiawei; McNeal, Suzanne; Babu, Raiju J; Baker, Daniel H; Bobier, William R; Hess, Robert F
2014-04-17
To better understand the relationship between dichoptic masking in normal vision and suppression in amblyopia we address three questions: First, what is the time course of dichoptic masking in normals and amblyopes? Second, is interocular suppression low-pass or band-pass in its spatial dependence? And third, in the above two regards, is dichoptic masking in normals different from amblyopic suppression? We measured the dependence of dichoptic masking in normal controls and amblyopes on the temporal duration of presentation under three conditions; monocular (the nontested eye-i.e., dominant eye of normals or nonamblyopic eye of amblyopes, being patched), dichoptic-luminance (the nontested eye seeing a mean luminance-i.e., a DC component) and dichoptic-contrast (the nontested eye seeing high-contrast visual noise). The subject had to detect a letter in the other eye, the contrast of which was varied. We found that threshold elevation relative to the patched condition occurred in both normals and amblyopes when the nontested eye saw either 1/f or band-pass filtered noise, but not just mean luminance (i.e., there was no masking from the DC component that corresponds to a channel responsive to a spatial frequency of 0 cyc/deg); longer presentation of the target (corresponding to lower temporal frequencies) produced greater threshold elevation. Dichoptic masking exhibits similar properties in both subject groups, being low-pass temporally and band-pass spatially, so that masking was greatest at the longest presentation durations and was not greatly affected by mean luminance in the nontested eye. Copyright 2014 The Association for Research in Vision and Ophthalmology, Inc.
Rao, Harsha L; Kumbar, Tukaram; Addepalli, Uday K; Bharti, Neha; Senthil, Sirisha; Choudhari, Nikhil S; Garudadri, Chandra S
2012-02-29
To evaluate the influence of a control group on the diagnostic accuracy of spectral-domain optical coherence tomography (SD-OCT) in early glaucoma. In a diagnostic, case-control study, 119 eyes of 60 normal subjects with no findings suspicious for glaucoma (control cohort 1); 76 eyes of 41 subjects referred by general ophthalmologists as glaucoma suspects based on optic disc morphology, but found by glaucoma experts to be normal but with physiological variations in their optic nerves (control cohort 2); and 65 eyes of 46 early-glaucoma patients (cases) underwent imaging of the optic nerve head (ONH), retinal nerve fiber layer (RNFL), and ganglion cell complex (GCC) by SD-OCT. Areas under the receiver operating characteristic curves (AUC) of ONH parameters discriminating glaucomatous eyes from normal eyes of control cohort 2 were significantly lesser (P < 0.001) than those discriminating glaucomatous eyes from normal eyes of control cohort 1. AUCs of RNFL parameters discriminating glaucomatous eyes from normal eyes of control cohorts 2 and 1 were comparable. Although the AUCs of GCC thickness parameters were comparable, AUCs of GCC focal and global loss volume in control cohort 2 (0.684 and 0.671. respectively) were significantly less (P < 0.05) than in control cohort 1 (0.881 and 0.841, respectively). The effectiveness of most SD-OCT parameters in detecting glaucoma significantly decreased when evaluated against a clinically relevant control group with suspicious-looking optic nerves compared with that against a control group consisting of normal subjects with no findings suspicious for glaucoma.
In-vivo imaging of photoreceptor structure and laser injury pathophysiology in the snake eye
NASA Astrophysics Data System (ADS)
Zwick, Harry; Elliot, Rowe; Li, Guo; Akers, Andre; Edsall, Peter R.; Stuck, Bruce E.
1999-06-01
Confocal scanning laser ophthalmoscopy (CSLO) combined with the high numerical aperture of the snake eye was used to evaluate laser injury at the photoreceptor and vascular retinal layers. An Argon laser source focused within a 35 micron retinal spot was used to produce a range of exposures from 152 to 1000 μjoules in the retinas of the Checkered Garter and Great Plains Rat snake. Anesthesia was induced with ketamine and xylazine. In vivo exposure sites measured post exposure showed unique photoreceptor damage characterized by surviving photoreceptors that were highly reflective and saturated, swollen and revealed more complex mode structure than normal photoreceptors when imaged under higher magnification. Evidence of oxidative stress was observed in photoreceptor cells peripheral to the lesion site as a late developing fluorescence (1-2 hour post exposure) following injection of Dichlorodihydrofluorescein diacetate, a marker of oxidative stress. At the anterior retina, acute exposure produced `sticky' blood cells, identified as leukocytes with Acridine orange. These findings indicate that laser retinal injury in large eyes, such as the human eye may involve pathophysiological cellular dynamics in both posterior and anterior retina and in normal retina adjacent to lesion sites. Photoreceptor movement outside the lesion site may relate to alterations in photoreceptor orientation and the efficiency of the photoreceptors quantal catch.
Schlesener, Brittany N; Scott, Erin M; Vallone, Lucien V
2017-11-07
A 1-year-old, female spayed, domestic shorthair cat presented for blepharospasm of the right eye. Slit-lamp biomicroscopic examination showed focal corneal ulceration and presumptive keratomalacia of the right eye. Examination of the left eye was normal apart from a focal endothelial opacity. Within the first 24 h of medical management, the right eye developed marked corneal edema and globular anterior protrusion of the corneal surface consistent with feline acute corneal hydrops (FACH). Surgical management consisted of a bridge conjunctival graft, nictitating membrane flap, and temporary tarsorrhaphy. Resolution of corneal edema and pain occurred in the right eye within 24 days. Spectral domain optical coherence tomography (SD-OCT) of the anterior segment was performed in both eyes. Conjunctival tissue from the bridge graft precluded examination of deeper corneal structures in the right eye. The left eye displayed a focal separation of the corneal endothelium and Descemet's membrane from the overlying stroma. These SD-OCT findings are similar to the analogous syndrome found in humans and represent a potential etiology for FACH of the right eye in the case presented here. Unfortunately, the cat was lost to follow-up and the progression of this lesion to FACH in the left eye could not be determined. © 2017 American College of Veterinary Ophthalmologists.
Migliaccio, Americo A; Della Santina, Charles C; Carey, John P; Minor, Lloyd B; Zee, David S
2006-08-01
We examined how the gain of the torsional vestibulo-ocular reflex (VOR) (defined as the instantaneous eye velocity divided by inverted head velocity) in normal humans is affected by eye position, target distance, and the plane of head rotation. In six normal subjects we measured three-dimensional (3D) eye and head rotation axes using scleral search coils, and 6D head position using a magnetic angular and linear position measurement device, during low-amplitude (approximately 20 degrees ), high-velocity (approximately 200 degrees/s), high-acceleration (approximately 4000 degrees /s2) rapid head rotations or 'impulses.' Head impulses were imposed manually and delivered in five planes: yaw (horizontal canal plane), pitch, roll, left anterior-right posterior canal plane (LARP), and right anterior-left posterior canal plane (RALP). Subjects were instructed to fix on one of six targets at eye level. Targets were either straight-ahead, 20 degrees left or 20 degrees right from midline, at distance 15 or 124 cm from the subject. Two subjects also looked at more eccentric targets, 30 degrees left or 30 degrees right from midline. We found that the vertical and horizontal VOR gains increased with the proximity of the target to the subject. Previous studies suggest that the torsional VOR gain should decrease with target proximity. We found, however, that the torsional VOR gain did not change for all planes of head rotation and for both target distances. We also found a dynamic misalignment of the vertical positions of the eyes during the torsional VOR, which was greatest during near viewing with symmetric convergence. This dynamic vertical skew during the torsional VOR arises, in part, because when the eyes are converged, the optical axes are not parallel to the naso-occipital axes around which the eyes are rotating. In five of six subjects, the average skew ranged 0.9 degrees -2.9 degrees and was reduced to <0.4 degrees by a 'torsional' quick-phase (around the naso-occipital axis) occurring <110 ms after the onset of the impulse. We propose that the torsional quick-phase mechanism during the torsional VOR could serve at least three functions: (1) resetting the retinal meridians closer to their usual orientation in the head, (2) correcting for the 'skew' deviation created by misalignment between the axes around which the eyes are rotating and the line of sight, and (3) taking the eyes back toward Listing's plane.
Wavefront-Guided Scleral Lens Correction in Keratoconus
Marsack, Jason D.; Ravikumar, Ayeswarya; Nguyen, Chi; Ticak, Anita; Koenig, Darren E.; Elswick, James D.; Applegate, Raymond A.
2014-01-01
Purpose To examine the performance of state-of-the-art wavefront-guided scleral contact lenses (wfgSCLs) on a sample of keratoconic eyes, with emphasis on performance quantified with visual quality metrics; and to provide a detailed discussion of the process used to design, manufacture and evaluate wfgSCLs. Methods Fourteen eyes of 7 subjects with keratoconus were enrolled and a wfgSCL was designed for each eye. High-contrast visual acuity and visual quality metrics were used to assess the on-eye performance of the lenses. Results The wfgSCL provided statistically lower levels of both lower-order RMS (p < 0.001) and higher-order RMS (p < 0.02) than an intermediate spherical equivalent scleral contact lens. The wfgSCL provided lower levels of lower-order RMS than a normal group of well-corrected observers (p < < 0.001). However, the wfgSCL does not provide less higher-order RMS than the normal group (p = 0.41). Of the 14 eyes studied, 10 successfully reached the exit criteria, achieving residual higher-order root mean square wavefront error (HORMS) less than or within 1 SD of the levels experienced by normal, age-matched subjects. In addition, measures of visual image quality (logVSX, logNS and logLIB) for the 10 eyes were well distributed within the range of values seen in normal eyes. However, visual performance as measured by high contrast acuity did not reach normal, age-matched levels, which is in agreement with prior results associated with the acute application of wavefront correction to KC eyes. Conclusions Wavefront-guided scleral contact lenses are capable of optically compensating for the deleterious effects of higher-order aberration concomitant with the disease, and can provide visual image quality equivalent to that seen in normal eyes. Longer duration studies are needed to assess whether the visual system of the highly aberrated eye wearing a wfgSCL is capable of producing visual performance levels typical of the normal population. PMID:24830371
Vandermeer, G; Chamy, Y; Pisella, P-J
2018-02-01
Dry eye is defined by a tear film instability resulting in variable but systematic fluctuations in quality of vision. Variability in optical quality can be demonstrated using a double pass aberrometer such as the Optical Quality Analyzing System, Visiometrics (OQAS). The goal of this work is to compare fluctuations in objective quality of vision measured by OQAS between treatment with normal saline eye drops and treatment with carmellose 0.5% and hyaluronic acid 0.1% (Optive Fusion [OF], Allergan) in patients with moderate dry eye syndrome. Optical quality was measured by evaluating the variations in the Optical Scattering Index (OSI) over 20seconds using the OQAS. Inclusion criteria were dry eye syndrome with an ocular surface disease index (OSDI) score >23 treated only with artificial tears. The patients were their own controls: OF in one eye and normal saline in the fellow eye. The choice of the subject eye and control eye was determined in a randomized fashion. OSI variations were measured in each eye before instillation, 5minutes and 2hours after instillation. The primary endpoint was OSI fluctuation over 20seconds of measurement. Secondary endpoints were the number of blinks and patient preference (preferred eye). Preliminary results were obtained on 19 patients. Average OSDI score was 36.8. Visual acuity was 10/10 with no significant difference between the two eyes. Prior to instillation, there was no significant difference between "normal saline" and "OF" eyes in terms of OSI, OSI variability or number of blinks. In the normal saline eye, there were no significant variations in mean OSI, OSI variability, OSI slope, or number of blinks. However, in the "OF" eye, there was a significant variation between initial and 2-hour OSI variability (0.363 versus 0.204, P<0.05), the average slope of OSI (0.04 versus 0.01, P<0.05) and the number of blinks (4.2 versus 2.8, P<0.05). Among the patients, 65% preferred the OF eye, 24% did not have a preference, and 11% preferred the normal saline eye. Objective quality of vision measured by OQAS is an interesting parameter for evaluating the effectiveness of a lacrimal substitute. The purpose of artificial tears is, among other things, to provide comfort and a reduction of dry eye symptoms such as poor quality of vision. This study demonstrates that 0.5% carmellose and 0.1% hyaluronic acid allowed better stabilization of the tear film and thus a significant improvement in the quality of vision compared to normal saline. Copyright © 2017 Elsevier Masson SAS. All rights reserved.
Vandermeer, G; Chamy, Y; Pisella, P-J
2018-03-01
Dry eye is defined by a tear film instability resulting in variable but systematic fluctuations in the quality of vision. Variability in optical quality can be demonstrated using a double pass aberrometer such as the OQAS (Optical Quality Analyzing System, Visiometrics). The goal of this work is to compare fluctuations in objective quality of vision measured by OQAS between treatment with normal saline eye drops and treatment with carmellose 0.5% and hyaluronic acid 0.1% (Optive Fusion [OF], Allergan) in patients with moderate dry eye syndrome. Optical quality was measured by evaluating the variations in the Optical Scattering Index (OSI) over 20seconds using the OQAS. Inclusion criteria were dry eye syndrome with an Ocular Surface Disease Index (OSDI) score>23 treated only with artificial tears. The patients were their own controls: OF in one eye and normal saline in the fellow eye. The choice of the subject eye and control eye was determined in a randomized fashion. OSI variations were measured in each eye before instillation, 5minutes and 2hours after instillation. The primary endpoint was OSI fluctuation over 20seconds of measurement. Secondary endpoints were the number of blinks and patient's preference (preferred eye). Preliminary results were obtained on 19 patients. Average OSDI score was 36.8. Visual acuity was 10/10 with no significant difference between the two eyes. Prior to instillation, there was no significant difference between "normal saline" and "OF" eyes in terms of OSI, OSI variability or number of blinks. In the normal saline eye, there was no significant variation in mean OSI, OSI variability, OSI slope, or number of blinks. However, in the "OF" eye, there was a significant variation between initial and 2-hour OSI variability (0.363 versus 0.204; P<0.05), the average slope of OSI (0.04 versus 0.01; P<0.05) and the number of blinks (4.2 versus 2.8; P<0.05). Sixty-five percent of patients preferred the OF eye, 24% did not have a preference, and 11% preferred the normal saline eye. Objective quality of vision measured by OQAS is an interesting parameter for evaluating the effectiveness of a lacrimal substitute. The purpose of artificial tears is, among other things, to provide comfort and a reduction of dry eye symptoms such as poor quality of vision. This study demonstrates that 0.5% carmellose and 0.1% hyaluronic acid allowed better stabilization of the tear film and thus a significant improvement in the quality of vision compared to normal saline. Copyright © 2018 Elsevier Masson SAS. All rights reserved.
Elastic Modulus Determination of Normal and Glaucomatous Human Trabecular Meshwork
Last, Julie A.; Pan, Tingrui; Ding, Yuzhe; Reilly, Christopher M.; Keller, Kate; Acott, Ted S.; Fautsch, Michael P.; Murphy, Christopher J.; Russell, Paul
2011-01-01
Purpose. Elevated intraocular pressure (IOP) is a risk factor for glaucoma. The principal outflow pathway for aqueous humor in the human eye is through the trabecular meshwork (HTM) and Schlemm's canal (SC). The junction between the HTM and SC is thought to have a significant role in the regulation of IOP. A possible mechanism for the increased resistance to flow in glaucomatous eyes is an increase in stiffness (increased elastic modulus) of the HTM. In this study, the stiffness of the HTM in normal and glaucomatous tissue was compared, and a mathematical model was developed to predict the impact of changes in stiffness of the juxtacanalicular layer of HTM on flow dynamics through this region. Methods. Atomic force microscopy (AFM) was used to measure the elastic modulus of normal and glaucomatous HTM. According to these results, a model was developed that simulated the juxtacanalicular layer of the HTM as a flexible membrane with embedded pores. Results. The mean elastic modulus increased substantially in the glaucomatous HTM (mean = 80.8 kPa) compared with that in the normal HTM (mean = 4.0 kPa). Regional variation was identified across the glaucomatous HTM, possibly corresponding to the disease state. Mathematical modeling suggested an increased flow resistance with increasing HTM modulus. Conclusions. The data indicate that the stiffness of glaucomatous HTM is significantly increased compared with that of normal HTM. Modeling exercises support substantial impairment in outflow facility with increased HTM stiffness. Alterations in the biophysical attributes of the HTM may participate directly in the onset and progression of glaucoma. PMID:21220561
NASA Astrophysics Data System (ADS)
Bellotti, Mariela I.; Bast, Walter; Berra, Alejandro; Bonetto, Fabián J.
2011-07-01
We present a novel experimental technique to determine eye ulcers in animals using a spectral electrical impedance technique. We expect that this technique will be useful in dry eye syndrome. We used a sensor that is basically a platinum (Pt) microelectrode electrically insulated by glass from a cylindrical stainless steel counter-electrode. This sensor was applied to the naked eye of New Zealand rabbits (2.0-3.5 kg in weight). Whereas half of the eyes were normal (control), we applied to the remainder a few drops of 20% (v/v) alcohol to produce an ulcer in the eye. Using a multispectral electrical impedance system we measured ulcerated and control eyes and observed significant difference between normal and pathological samples. We also investigated the effects of different applied pressures and natural degradation of initially normal eyes as a function of time. We believe that this technique could be sufficiently sensitive and repetitive to help diagnose ocular surface diseases such as dry eye syndrome.
Bellotti, Mariela I; Bast, Walter; Berra, Alejandro; Bonetto, Fabián J
2011-07-01
We present a novel experimental technique to determine eye ulcers in animals using a spectral electrical impedance technique. We expect that this technique will be useful in dry eye syndrome. We used a sensor that is basically a platinum (Pt) microelectrode electrically insulated by glass from a cylindrical stainless steel counter-electrode. This sensor was applied to the naked eye of New Zealand rabbits (2.0-3.5 kg in weight). Whereas half of the eyes were normal (control), we applied to the remainder a few drops of 20% (v/v) alcohol to produce an ulcer in the eye. Using a multispectral electrical impedance system we measured ulcerated and control eyes and observed significant difference between normal and pathological samples. We also investigated the effects of different applied pressures and natural degradation of initially normal eyes as a function of time. We believe that this technique could be sufficiently sensitive and repetitive to help diagnose ocular surface diseases such as dry eye syndrome.
How virtual reality works: illusions of vision in "real" and virtual environments
NASA Astrophysics Data System (ADS)
Stark, Lawrence W.
1995-04-01
Visual illusions abound in normal vision--illusions of clarity and completeness, of continuity in time and space, of presence and vivacity--and are part and parcel of the visual world inwhich we live. These illusions are discussed in terms of the human visual system, with its high- resolution fovea, moved from point to point in the visual scene by rapid saccadic eye movements (EMs). This sampling of visual information is supplemented by a low-resolution, wide peripheral field of view, especially sensitive to motion. Cognitive-spatial models controlling perception, imagery, and 'seeing,' also control the EMs that shift the fovea in the Scanpath mode. These illusions provide for presence, the sense off being within an environment. They equally well lead to 'Telepresence,' the sense of being within a virtual display, especially if the operator is intensely interacting within an eye-hand and head-eye human-machine interface that provides for congruent visual and motor frames of reference. Interaction, immersion, and interest compel telepresence; intuitive functioning and engineered information flows can optimize human adaptation to the artificial new world of virtual reality, as virtual reality expands into entertainment, simulation, telerobotics, and scientific visualization and other professional work.
McMenamin, P G; Loeffler, K U
1990-06-01
The subretinal spaces (SRS) in 17 human foetal eyes were investigated by light microscopy and scanning and transmission electron microscopy. A hitherto undocumented group of pleomorphic cells was detected on the apical surface of the retinal pigment epithelium (RPE) and on the undersurface of the neural retina. These cells formed a regularly spaced array in the peripheral SRS, particularly in the most anterior portion nearest the ciliary body anlage. The morphology of the SRS cells ranged from a small round or ovoid form with a few short basal pseudopodia to an extremely flattened dendritic form. Ultrastructural features, such as large melanophagolysosomes, consistent with a phagocytic function, were observed in some cells. These SRS cells bore remarkable resemblance to epiplexus and supraependymal cells, considered to be the resident population of macrophages on the ventricular surfaces of the brain. This morphological parallelism, together with the anatomically homologous location, is strong evidence that SRS cells represent a normal population of macrophages in the developing human eye. No features consistent with an RPE or neuronal origin were observed. The possible role of these cells as transient phagocytes in the SRS with a possible destiny as retinal microglia is discussed.
Dooley, K O; Farmer, A
1988-08-01
Neurolinguistic programming's hypothesized eye movements were measured independently using videotapes of 10 nonfluent aphasic and 10 control subjects matched for age and sex. Chi-squared analysis indicated that eye-position responses were significantly different for the groups. Although earlier research has not supported the hypothesized eye positions for normal subjects, the present findings support the contention that eye-position responses may differ between neurologically normal and aphasic individuals.
Verma, Ashutosh; Kumar, Pawan; Babb, Kelly; Timoney, John F.; Stevenson, Brian
2010-01-01
Infection by Leptospira interrogans has been causally associated with human and equine uveitis. Studies in our laboratories have demonstrated that leptospiral lipoprotein LruA and LruB are expressed in the eyes of uveitic horses, and that antibodies directed against LruA and LruB react with equine lenticular and retinal extracts, respectively. These reactivities were investigated further by performing immunofluorescent assays on lenticular and retinal tissue sections. Incubation of lens tissue sections with LruA-antiserum and retinal sections with LruB-antiserum resulted in positive fluorescence. By employing two-dimensional gel analyses followed by immunoblotting and mass spectrometry, lens proteins cross-reacting with LruA antiserum were identified to be α-crystallin B and vimentin. Similarly, mass spectrometric analyses identified β-crystallin B2 as the retinal protein cross-reacting with LruB-antiserum. Purified recombinant human α-crystallin B and vimentin were recognized by LruA-directed antiserum, but not by control pre-immune serum. Recombinant β-crystallin B2 was likewise recognized by LruB-directed antiserum, but not by pre-immune serum. Moreover, uveitic eye fluids contained significantly higher levels of antiibodies that recognized α-crystallin B, β-crystallin B2 and vimentin than did normal eye fluids. Our results indicate that LruA and LruB share immuno-relevant epitopes with eye proteins, suggesting that cross-reactive antibody interactions with eye antigens may contribute to immunopathogenesis of Leptospira-associated recurrent uveitis. PMID:20689825
Verma, Ashutosh; Kumar, Pawan; Babb, Kelly; Timoney, John F; Stevenson, Brian
2010-08-03
Infection by Leptospira interrogans has been causally associated with human and equine uveitis. Studies in our laboratories have demonstrated that leptospiral lipoprotein LruA and LruB are expressed in the eyes of uveitic horses, and that antibodies directed against LruA and LruB react with equine lenticular and retinal extracts, respectively. These reactivities were investigated further by performing immunofluorescent assays on lenticular and retinal tissue sections. Incubation of lens tissue sections with LruA-antiserum and retinal sections with LruB-antiserum resulted in positive fluorescence. By employing two-dimensional gel analyses followed by immunoblotting and mass spectrometry, lens proteins cross-reacting with LruA antiserum were identified to be alpha-crystallin B and vimentin. Similarly, mass spectrometric analyses identified beta-crystallin B2 as the retinal protein cross-reacting with LruB-antiserum. Purified recombinant human alpha-crystallin B and vimentin were recognized by LruA-directed antiserum, but not by control pre-immune serum. Recombinant beta-crystallin B2 was likewise recognized by LruB-directed antiserum, but not by pre-immune serum. Moreover, uveitic eye fluids contained significantly higher levels of antiibodies that recognized alpha-crystallin B, beta-crystallin B2 and vimentin than did normal eye fluids. Our results indicate that LruA and LruB share immuno-relevant epitopes with eye proteins, suggesting that cross-reactive antibody interactions with eye antigens may contribute to immunopathogenesis of Leptospira-associated recurrent uveitis.
Barrett, Brendan T.; Panesar, Gurvinder K.; Scally, Andrew J.; Pacey, Ian E.
2013-01-01
Background Adults with amblyopia (‘lazy eye’), long-standing strabismus (ocular misalignment) or both typically do not experience visual symptoms because the signal from weaker eye is given less weight than the signal from its fellow. Here we examine the contribution of the weaker eye of individuals with strabismus and amblyopia with both eyes open and with the deviating eye in its anomalous motor position. Methodology/Results The task consisted of a blue-on-yellow detection task along a horizontal line across the central 50 degrees of the visual field. We compare the results obtained in ten individuals with strabismic amblyopia with ten visual normals. At each field location in each participant, we examined how the sensitivity exhibited under binocular conditions compared with sensitivity from four predictions, (i) a model of binocular summation, (ii) the average of the monocular sensitivities, (iii) dominant-eye sensitivity or (iv) non-dominant-eye sensitivity. The proportion of field locations for which the binocular summation model provided the best description of binocular sensitivity was similar in normals (50.6%) and amblyopes (48.2%). Average monocular sensitivity matched binocular sensitivity in 14.1% of amblyopes’ field locations compared to 8.8% of normals’. Dominant-eye sensitivity explained sensitivity at 27.1% of field locations in amblyopes but 21.2% in normals. Non-dominant-eye sensitivity explained sensitivity at 10.6% of field locations in amblyopes but 19.4% in normals. Binocular summation provided the best description of the sensitivity profile in 6/10 amblyopes compared to 7/10 of normals. In three amblyopes, dominant-eye sensitivity most closely reflected binocular sensitivity (compared to two normals) and in the remaining amblyope, binocular sensitivity approximated to an average of the monocular sensitivities. Conclusions Our results suggest a strong positive contribution in habitual viewing from the non-dominant eye in strabismic amblyopes. This is consistent with evidence from other sources that binocular mechanisms are frequently intact in strabismic and amblyopic individuals. PMID:24205005
The evaluation of eye pain with a normal ocular exam.
Lee, Andrew G; Brazis, Paul W
2003-12-01
Eye pain with or without associated head or face pain is a common complaint to the ophthalmologist. The ocular exam may reveal the etiology (e.g., corneal disease, angle closure glaucoma) but typically the exam is normal. This paper reviews the evaluation and management of eye pain with a "normal" ocular exam, including: 1) subtle findings on ocular exam; 2) transient findings on exam, and 3) no abnormal ocular findings. Ophthalmologists should be aware of the various etiologies for eye pain and the specific and distinctive features that make the diagnosis.
Fast hierarchical knowledge-based approach for human face detection in color images
NASA Astrophysics Data System (ADS)
Jiang, Jun; Gong, Jie; Zhang, Guilin; Hu, Ruolan
2001-09-01
This paper presents a fast hierarchical knowledge-based approach for automatically detecting multi-scale upright faces in still color images. The approach consists of three levels. At the highest level, skin-like regions are determinated by skin model, which is based on the color attributes hue and saturation in HSV color space, as well color attributes red and green in normalized color space. In level 2, a new eye model is devised to select human face candidates in segmented skin-like regions. An important feature of the eye model is that it is independent of the scale of human face. So it is possible for finding human faces in different scale with scanning image only once, and it leads to reduction the computation time of face detection greatly. In level 3, a human face mosaic image model, which is consistent with physical structure features of human face well, is applied to judge whether there are face detects in human face candidate regions. This model includes edge and gray rules. Experiment results show that the approach has high robustness and fast speed. It has wide application perspective at human-computer interactions and visual telephone etc.
Evitts, Paul; Gallop, Robert
2011-01-01
There is a large body of research demonstrating the impact of visual information on speaker intelligibility in both normal and disordered speaker populations. However, there is minimal information on which specific visual features listeners find salient during conversational discourse. To investigate listeners' eye-gaze behaviour during face-to-face conversation with normal, laryngeal and proficient alaryngeal speakers. Sixty participants individually participated in a 10-min conversation with one of four speakers (typical laryngeal, tracheoesophageal, oesophageal, electrolaryngeal; 15 participants randomly assigned to one mode of speech). All speakers were > 85% intelligible and were judged to be 'proficient' by two certified speech-language pathologists. Participants were fitted with a head-mounted eye-gaze tracking device (Mobile Eye, ASL) that calculated the region of interest and mean duration of eye-gaze. Self-reported gaze behaviour was also obtained following the conversation using a 10 cm visual analogue scale. While listening, participants viewed the lower facial region of the oesophageal speaker more than the normal or tracheoesophageal speaker. Results of non-hierarchical cluster analyses showed that while listening, the pattern of eye-gaze was predominantly directed at the lower face of the oesophageal and electrolaryngeal speaker and more evenly dispersed among the background, lower face, and eyes of the normal and tracheoesophageal speakers. Finally, results show a low correlation between self-reported eye-gaze behaviour and objective regions of interest data. Overall, results suggest similar eye-gaze behaviour when healthy controls converse with normal and tracheoesophageal speakers and that participants had significantly different eye-gaze patterns when conversing with an oesophageal speaker. Results are discussed in terms of existing eye-gaze data and its potential implications on auditory-visual speech perception. © 2011 Royal College of Speech & Language Therapists.
Abreau, Kerstin; Callan, Christine; Kottaiyan, Ranjini; Zhang, Aizhong; Yoon, Geunyoung; Aquavella, James V; Zavislan, James; Hindman, Holly B
2016-01-01
To compare the temperatures of the ocular surface, eyelid, and periorbital skin in normal eyes with Sjögren's syndrome (SS) eyes, evaporative dry eyes (EDE), and aqueous deficient dry eyes (ADDE). 10 eyes were analyzed in each age-matched group (normal, SS, EDE, and ADDE). A noninvasive infrared thermal camera captured two-dimensional images in three regions of interest (ROI) in each of three areas: the ocular surface, the upper eyelid, and the periorbital skin within a controlled environmental chamber. Mean temperatures in each ROI were calculated from the videos. Ocular surface time-segmented cooling rates were calculated over a 5-s blink interval. Relative to normal eyes, dry eyes had lower initial central OSTs (SS -0.71°C, EDE -0.55°C, ADDE -0.95°C, KW P<.0001) and lower central upper lid temperatures (SS -0.24°C, ADDE -0.51°C, and EDE -0.54°C, KW P<.0001). ADDE eyes had the lowest initial central OST (P<.0001), while EDE eyes had the lowest central lid temperature and lower periorbital temperatures (P<.0001). Over the 5-s interblink interval, the greatest rate of temperature loss occurred following eyelid opening, but varied by group (normals -0.52, SS -0.73, EDE -0.63, and ADDE -0.75°C/s). The ADDE group also had the most substantial heat loss over the 5-s interblink interval (-0.97°C). Differences in OST may be related to thermal differences in lids and periorbita along with an altered tear film. Thermography of the ocular surface, lids, and surrounding tissues may help to differentiate between different etiologies of dry eye. Copyright © 2016 Elsevier Inc. All rights reserved.
Fukuda, Masamichi; Inoue, Amane; Sasaki, Kazuyuki; Takahashi, Nobuo
2004-01-01
Pharmacokinetic studies of antibacterial agents for infectious eye diseases have usually been performed on normal rabbit eyes. In this study, the intraocular penetration of fluoroquinolone ophthalmic solutions was determined in normal rabbit eyes and in rabbit eyes that had the corneal epithelium intentionally removed. We determined the intraocular penetration of ofloxacin (OFLX), levofloxacin (LVFX), and norfloxacin (NFLX), fluoroquinolone ophthalmic solutions that are already on the market and undergoing clinical studies, by injecting 50 microl of each solution into the cul-de-sacs of rabbit eyes three times at 15-min intervals. The drug concentration at 10, 30, 60, 120, and 240 min after final instillation was determined by high-performance liquid chromatography. The maximum concentration in the aqueous humor of normal rabbit eyes was 2.09 +/- 1.56 microg/ml (60 min, OFLX), 2.57 +/- 1.00 microg/ml (30 min, LVFX), and 0.42 +/- 0.12 microg/ml (120 min, NFLX). The drug concentration in the aqueous humor of eyes with intentionally removed corneal epithelium was 12.50 +/- 5.62 microg/ml (30 min, OFLX), 9.02 +/- 2.45 microg/ml (60 min, LVFX), and 8.54 +/- 5.17 microg/ml (30 min, NFLX). The drug penetration of the eye drops into eyes with removed corneal epithelium was around 6 times (OFLX), 3.5 times (LVFX), and 20 times (NFLX) higher than the penetration into the eye with normal cornea. Among the pharmacokinetic parameters of the three ophthalmic solutions according to the one-compartment model, the maximum concentration in the aqueous and the area under the concentration-time curve in the aqueous tended to be higher in the eyes with intentionally removed corneal epithelia than in those with normal corneas.
Comparison of noncontact infrared and remote sensor thermometry in normal and dry eye patients.
Singh, G; Singh Bhinder, H
To evaluate the role of closed chamber infrared and remote sensor thermometry in normal and dry eye patients. The study was conducted on 51 dry eye cases (102 eyes), 26 men and 25 women aged 19 to 65 years (35.3614.36), and 51 normal (102 eyes) age- and sex-matched control subjects. The criteria for dry eye were Schirm e r-1 (<10 m/5 min), FTBUT (<10 sec), nd lissamine green score (>2). The remote sensor and infrared thermometry was done in losed chamber around the eye in closed and open eye positions. In normal eyes, closed chamber infrared thermometry recorded temperature 34.770.37 C in closed eye position and 35.020.39 C in open eye position as compared to 27.912.46 C in closed eye position and 28.012.46 C in open position with remote sensor thermometry. The difference in temperature from closed to open position was 0.250.90 C in infrared thermometry and 0.100.00 C with remote sensor thermometry, which was statistically significant (p<0.0000). In dry eye, the infrared therm o m e t ry recorded 35.080.61 C temperature in closed eye position and 35.530.63 C in open eye position as compared to 27.412.48 C in open and closed eye position with remote sensor thermometry. The difference in temperature from closed to open eye position was 0.450.14 C (p<0.0000) with infrared thermometry as compared to no change 0.000.00 C with remote sensor thermometry (p<0.0000). Remote sensor thermometry proved better for diagnosis of dry eye disease as it showed no change in temperature under closed chamber in closed and open position (p=0.0000). Infrared thermometry was better in recording the absolute temperature from any point on the eye.
Comparison of noncontact infrared and remote sensor thermometry in normal and dry eye patients.
Singh, G; Bhinder, H Singh
2005-01-01
To evaluate the role of closed chamber infrared and remote sensor thermometry in normal and dry eye patients. The study was conducted on 51 dry eye cases (102 eyes), 26 men and 25 women aged 19 to 65 years (35.36+/-14.36), and 51 normal (102 eyes) age- and sex-matched control subjects. The criteria for dry eye were Schirmer-1 (<10 m/5 min), FTBUT (<10 sec), nd lissamine green score (>2). The remote sensor and infrared thermometry was done in closed chamber around the eye in closed and open eye positions. In normal eyes, closed chamber infrared thermometry recorded temperature 34.77+/-0.37 degrees C in closed eye position and 35.02+/-0.39 degrees C in open eye position as compared to 27.91+/-2.46 degrees C in closed eye position and 28.01+/-2.46 degrees C in open position with remote sensor thermometry. The difference in temperature from closed to open position was 0.25+/-0.90 degrees C in infrared thermometry and 0.10+/-0.00 degrees C with remote sensor thermometry, which was statistically significant (p<0.0000). In dry eye, the infrared thermometry recorded 35.08+/-0.61 degrees C temperature in closed eye position and 35.53+/-0.63 degrees C in open eye position as compared to 27.41+/-2.48 degrees C in open and closed eye position with remote sensor thermometry. The difference in temperature from closed to open eye position was 0.45+/-0.14 degrees C (p<0.0000) with infrared thermometry as compared to no change 0.00+/-0.00 degrees C with remote sensor thermometry (p<0.0000). Remote sensor thermometry proved better for diagnosis of dry eye disease as it showed no change in temperature under closed chamber in closed and open position (p=0.0000). Infrared thermometry was better in recording the absolute temperature from any point on the eye.
Racioethnic Differences in Human Posterior Scleral and Optic Nerve Stump Deformation
Tamimi, Ehab A.; Pyne, Jeffrey D.; Muli, Dominic K.; Axman, Katelyn F.; Howerton, Stephen J.; Davis, Matthew R.; Girkin, Christopher A.; Vande Geest, Jonathan P.
2017-01-01
Purpose The purpose of this study was to quantify the biomechanical response of human posterior ocular tissues from donors of various racioethnic groups to better understand how differences in these properties may play a role in the racioethnic health disparities known to exist in glaucoma. Methods Sequential digital image correlation (S-DIC) was used to measure the pressure-induced surface deformations of 23 normal human posterior poles from three racioethnic groups: African descent (AD), European descent (ED), and Hispanic ethnicity (HIS). Regional in-plane principal strains were compared across three zones: the optic nerve stump (ONS), the peripapillary (PP) sclera, and non-PP sclera. Results The PP scleral tensile strains were found to be lower for ED eyes compared with AD and HIS eyes at 15 mm Hg (P = 0.024 and 0.039, respectively). The mean compressive strains were significantly higher for AD eyes compared with ED eyes at 15 mm Hg (P = 0.018). We also found that the relationship between tensile strain and pressure was significant for those of ED and HIS eyes (P < 0.001 and P = 0.004, respectively), whereas it was not significant for those of AD (P = 0.392). Conclusions Our results suggest that, assuming glaucomatous nerve loss is caused by mechanical strains in the vicinity of the optic nerve head, the mechanism of increased glaucoma prevalence may be different in those of AD versus HIS. Our ONS strain analysis also suggested that it may be important to account for ONS geometry and material properties in future scleral biomechanical analysis. PMID:28846773
Whole eye wavefront aberrations in Mexican male subjects.
Cantú, Roberto; Rosales, Marco A; Tepichín, Eduardo; Curioca, Andrée; Montes, Victor; Bonilla, Julio
2004-01-01
To analyze the characteristics, incidence, and appearance of wavefront aberrations in undilated, normal, unoperated eyes. Eighty-eight eyes of 44 healthy male Mexican subjects (mean age 25.32 years, range 18 to 36 yr) were divided into three groups based on uncorrected visual acuity of greater than or equal to 20/20, 20/30, or 20/40. UCVA measurements were obtained using an Acuity Max computer screen chart. Wavefront aberrations were measured with the Nidek OPD-Scan ARK 10000, Ver. 1.11b. All measurements were carried out at the same center by the same technician during a single session, following manufacturer instructions. Background illumination was 3 Lux. Wavefront aberration measurements for each group were statistically analyzed using StatView; an average eye was characterized and the resulting aberrations were simulated using MATLAB. We obtained wavefront aberration maps for the 20/20 undilated normal unoperated eyes for total, low, and high order aberration coefficients. Wavefront maps for right eyes were practically the same as those for left eyes. Higher aberrations did not contribute substantially to total wavefront analysis. Average aberrations of this "normal eye" will be used as criteria to decide the necessity of wavefront-guided ablation in our facilities. We will focus on the nearly zero average of high order aberrations in this normal whole eye as a reference to be matched.
Syngeneic Schwann cell transplantation preserves vision in RCS rat without immunosuppression.
McGill, Trevor J; Lund, Raymond D; Douglas, Robert M; Wang, Shaomei; Lu, Bin; Silver, Byron D; Secretan, Matt R; Arthur, Jennifer N; Prusky, Glen T
2007-04-01
To evaluate the efficacy of immunologically compatible Schwann cells transplanted without immunosuppression in the RCS rat retina to preserve vision. Syngeneic (dystrophic RCS) Schwann cells harvested from sciatic nerves were cultured and transplanted into one eye of dystrophic RCS rats at an early stage of retinal degeneration. Allogeneic (Long-Evans) Schwann cells and unoperated eyes served as controls. Vision through transplanted and unoperated eyes was then quantified using two visual behavior tasks, one measuring the spatial frequency and contrast sensitivity thresholds of the optokinetic response (OKR) and the other measuring grating acuity in a perception task. Spatial frequency thresholds measured through syngeneically transplanted eyes maintained near normal spatial frequency sensitivity for approximately 30 weeks, whereas thresholds through control eyes deteriorated to less than 20% of normal over the same period. Contrast sensitivity was preserved through syngeneically transplanted eyes better than through allogeneic and unoperated eyes, at all spatial frequencies. Grating acuity measured through syngeneically transplanted eyes was maintained at approximately 60% of normal, whereas acuity of allogeneically transplanted eyes was significantly lower at approximately 40% of normal. The ability of immunoprivileged Schwann cell transplants to preserve vision in RCS rats indicates that transplantation of syngeneic Schwann cells holds promise as a preventive treatment for retinal degenerative disease.
Konz, Ioana; Fernández, Beatriz; Fernández, M Luisa; Pereiro, Rosario; González, Héctor; Alvarez, Lydia; Coca-Prados, Miguel; Sanz-Medel, Alfredo
2013-04-01
Laser ablation coupled to inductively coupled plasma mass spectrometry has been developed for the elemental imaging of Mg, Fe and Cu distribution in histological tissue sections of fixed eyes, embedded in paraffin, from human donors (cadavers). This work presents the development of a novel internal standard correction methodology based on the deposition of a homogeneous thin gold film on the tissue surface and the use of the (197)Au(+) signal as internal standard. Sample preparation (tissue section thickness) and laser conditions were carefully optimized, and internal normalisation using (197)Au(+) was compared with (13)C(+) correction for imaging applications. (24)Mg(+), (56)Fe(+) and (63)Cu(+) distributions were investigated in histological sections of the anterior segment of the eye (including the iris, ciliary body, cornea and trabecular meshwork) and were shown to be heterogeneously distributed along those tissue structures. Reproducibility was assessed by imaging different human eye sections from the same donor and from ten different eyes from adult normal donors, which showed that similar spatial maps were obtained and therefore demonstrate the analytical potential of using (197)Au(+) as internal standard. The proposed analytical approach could offer a robust tool with great practical interest for clinical studies, e.g. to investigate trace element distribution of metals and their alterations in ocular diseases.
Herbal Supplement in a Buffer for Dry Eye Syndrome Treatment.
Chen, Hung-Chang; Chen, Zhi-Yu; Wang, Tsung-Jen; Drew, Victor J; Tseng, Ching-Li; Fang, Hsu-Wei; Lin, Feng-Huei
2017-08-03
Dry eye syndrome (DES) is one of the most common types of ocular diseases. There is a major need to treat DES in a simple yet efficient way. Artificial tears (AT) are the most commonly used agents for treating DES, but are not very effective. Herbal extractions of ferulic acid (FA), an anti-oxidant agent, and kaempferol (KM), an anti-inflammatory reagent, were added to buffer solution (BS) to replace ATs for DES treatment. The cytotoxicity and anti-inflammatory effects were examined in vitro by co-culture with human corneal epithelial cells (HCECs) to obtain the optimal concentration of KM and FA for treating HCECs. Physical properties of BS, such as pH value, osmolality, and refractive index were also examined. Then, rabbits with DES were used for therapeutic evaluation. Tear production, corneal damage, and ocular irritation in rabbits' eyes were examined. The non-toxic concentrations of KM and FA for HCEC cultivation over 3 days were 1 µM and 100 µM, respectively. Live/dead stain results also show non-toxicity of KM and FA for treating HCECs. Lipopolysaccharide-stimulated HCECs in inflammatory conditions treated with 100 µM FA and 1 µM KM (FA100/KM1) showed lower IL-1B , IL-6 , IL-8 , and TNFα expression when examined by real-time PCR. The BS with FA100/KM1 had neutral pH, and a similar osmolality and refractive index to human tears. Topical delivery of BS + FA100/KM1 showed no irritation to rabbit eyes. The corneal thickness in the BS + FA100/KM1 treated group was comparable to normal eyes. Results of DES rabbits treated with BS + FA100/KM1 showed less corneal epithelial damage and higher tear volume than the normal group. In conclusion, we showed that the combination of FA (100 µM) and KM (1 µM) towards treating inflamed HCECs had an anti-inflammatory effect, and it is effective in treating DES rabbits when BS is added in combination with these two herbal supplements and used as a topical eye drop.
Hoffman, Allison; Sisler, Steve; Pappania, Marie; Hsu, Kimberly; Ross, Maya; Ofri, Ron
2018-05-01
To determine whether pre-operative electroretinography (ERG) predicts postoperative vision in dogs undergoing retinal reattachment surgery (RRS). This 18-month prospective study recorded signalment, duration, cause, and extent of retinal detachment and pre-operative vision status. Rod and mixed rod-cone ERG responses were recorded prior to RRS. Referring veterinary ophthalmologists assessed vision 2 months postoperatively. Thirty dogs (40 affected eyes) aged 4 months to 12.1 years were included. The detachment extent was 150 ° -320 ° in 15 of 40 eyes, 360 ° in 24 of 40 eyes, and not recorded in one eye. Most dogs had a genetic predisposition for retinal detachment. Eight eyes of seven dogs had previous cataract surgery. Mean estimated duration of detachment prior to surgery was 24.5 ± 19.6 days. Pre-operatively, 34 of 40 eyes were blind, two of 40 eyes were sighted, and four of 40 eyes had severely diminished vision. Compared to normative ERG values in our clinics, pre-operative ERGs were classified as "normal" in five of 40 eyes, "attenuated" in seven of 40 eyes, and "flat" in 28 of 40 eyes. Following RRS, the retina was fully reattached in all operated eyes. Two-month postoperatively, 30 of 40 eyes had "normal" vision as defined by referring veterinary ophthalmologists, six of 40 eyes had "limited" or "diminished" vision and four of 40 eyes were blind. Normal vision was regained in 12 of 12 (100%) of eyes with normal or attenuated pre-operative ERG's, but only in 18 of 28 (64%) of eyes with flat pre-operative ERG 's (Linear-by-linear test, P = 0.029). A recordable pre-operative ERG, even if attenuated, is associated with return of vision in canine RRS patients, and is a favorable prognostic indicator. © 2017 American College of Veterinary Ophthalmologists.
Hurmeric, Volkan; Sahin, Afsun; Ozge, Gokhan; Bayer, Atilla
2010-06-01
To investigate the relationship between corneal biomechanical properties and confocal microscopy (CM) findings in normal and keratoconic eyes. The study consisted of 28 eyes of 28 healthy volunteers and 23 eyes of 15 patients with keratoconus. The diagnosis of keratoconus was made with corneal topography and clinical findings. The corneal hysteresis (CH) and corneal resistance factor (CRF) were measured by the ocular response analyzer. In vivo CM was performed with NIDEK Confoscan 3. CH and CRF were compared with corneal morphological findings (detailed cell counts of endothelial, stromal, and epithelial cells) in vivo. CH was 10.1 +/- 1.3 mm Hg in normal eyes and 7.4 +/- 1.5 mm Hg in keratoconic eyes (P < 0.0001). CRF was 10.1 +/- 1.8 mm Hg in normal eyes and 6.2 +/- 1.4 mm Hg in keratoconic eyes (P < 0.0001). CH and CRF were negatively correlated with full-thickness stromal keratocyte density (P < 0.01; r = -0.52 and P < 0.001; r = -0.67, respectively) in healthy eyes. Keratocyte density of the posterior half of the stroma was found to be significantly related with CRF in healthy eyes (beta = -0.404; P = 0.01). There was no significant relationship among CH, CRF, and CM findings in eyes with keratoconus. There is a significant relationship between CRF and keratocyte density of the posterior half of the stroma in healthy eyes. Our results suggest that corneal elasticity is related to not only stromal matrix but also cellular structure of the cornea.
[The eye, the optic system and its anomalies].
Cohen, S Y
1993-09-15
The eye is a perceptive system with extremely complex physiology, although its optical properties can be assimilated to those of spherical diopters. Various approximations make it possible to reduce the eyeball to a single convex diopter. With a normal eye the image of an object situated ad infinitum focuses on the retina. The normal eye is called emmetropic. Otherwise, the eye is called ametropic. Several types of ametropy exist. When the image focuses in front of the retina the eye is said to be myopic. When the image focuses behind the retina the eye is called hypermetropic (or hyperopic). When the image of an object differs according to various focusing axes, the eye is said to be astigmatic.
Thurtell, M J; Black, R A; Halmagyi, G M; Curthoys, I S; Aw, S T
1999-05-01
Vertical eye position-dependence of the human vestibuloocular reflex during passive and active yaw head rotations. The effect of vertical eye-in-head position on the compensatory eye rotation response to passive and active high acceleration yaw head rotations was examined in eight normal human subjects. The stimuli consisted of brief, low amplitude (15-25 degrees ), high acceleration (4,000-6,000 degrees /s2) yaw head rotations with respect to the trunk (peak velocity was 150-350 degrees /s). Eye and head rotations were recorded in three-dimensional space using the magnetic search coil technique. The input-output kinematics of the three-dimensional vestibuloocular reflex (VOR) were assessed by finding the difference between the inverted eye velocity vector and the head velocity vector (both referenced to a head-fixed coordinate system) as a time series. During passive head impulses, the head and eye velocity axes aligned well with each other for the first 47 ms after the onset of the stimulus, regardless of vertical eye-in-head position. After the initial 47-ms period, the degree of alignment of the eye and head velocity axes was modulated by vertical eye-in-head position. When fixation was on a target 20 degrees up, the eye and head velocity axes remained well aligned with each other. However, when fixation was on targets at 0 and 20 degrees down, the eye velocity axis tilted forward relative to the head velocity axis. During active head impulses, the axis tilt became apparent within 5 ms of the onset of the stimulus. When fixation was on a target at 0 degrees, the velocity axes remained well aligned with each other. When fixation was on a target 20 degrees up, the eye velocity axis tilted backward, when fixation was on a target 20 degrees down, the eye velocity axis tilted forward. The findings show that the VOR compensates very well for head motion in the early part of the response to unpredictable high acceleration stimuli-the eye position- dependence of the VOR does not become apparent until 47 ms after the onset of the stimulus. In contrast, the response to active high acceleration stimuli shows eye position-dependence from within 5 ms of the onset of the stimulus. A model using a VOR-Listing's law compromise strategy did not accurately predict the patterns observed in the data, raising questions about how the eye position-dependence of the VOR is generated. We suggest, in view of recent findings, that the phenomenon could arise due to the effects of fibromuscular pulleys on the functional pulling directions of the rectus muscles.
Extralenticular and Lenticular Aspects of Accommodation and Presbyopia in Human Versus Monkey Eyes
Croft, Mary Ann; McDonald, Jared P.; Katz, Alexander; Lin, Ting-Li; Lütjen-Drecoll, Elke; Kaufman, Paul L.
2013-01-01
Purpose. To determine if the accommodative forward movements of the vitreous zonule and lens equator occur in the human eye, as they do in the rhesus monkey eye; to investigate the connection between the vitreous zonule posterior insertion zone and the posterior lens equator; and to determine which components—muscle apex width, lens thickness, lens equator position, vitreous zonule, circumlental space, and/or other intraocular dimensions, including those stated in the objectives above—are most important in predicting accommodative amplitude and presbyopia. Methods. Accommodation was induced pharmacologically in 12 visually normal human subjects (ages 19–65 years) and by midbrain electrical stimulation in 11 rhesus monkeys (ages 6–27 years). Ultrasound biomicroscopy imaged the entire ciliary body, anterior and posterior lens surfaces, and the zonule. Relevant distances were measured in the resting and accommodated eyes. Stepwise regression analysis determined which variables were the most important predictors. Results. The human vitreous zonule and lens equator move forward (anteriorly) during accommodation, and their movements decline with age, as in the monkey. Over all ages studied, age could explain accommodative amplitude, but not as well as accommodative lens thickening and resting muscle apex thickness did together. Accommodative change in distances between the vitreous zonule insertion zone and the posterior lens equator or muscle apex were important for predicting accommodative lens thickening. Conclusions. Our findings quantify the movements of the zonule and ciliary muscle during accommodation, and identify their age-related changes that could impact the optical change that occurs during accommodation and IOL function. PMID:23745002
Takayama, Kohei; Ooto, Sotaro; Hangai, Masanori; Ueda-Arakawa, Naoko; Yoshida, Sachiko; Akagi, Tadamichi; Ikeda, Hanako Ohashi; Nonaka, Atsushi; Hanebuchi, Masaaki; Inoue, Takashi; Yoshimura, Nagahisa
2013-05-01
To detect pathologic changes in retinal nerve fiber bundles in glaucomatous eyes seen on images obtained by adaptive optics (AO) scanning laser ophthalmoscopy (AO SLO). Prospective cross-sectional study. Twenty-eight eyes of 28 patients with open-angle glaucoma and 21 normal eyes of 21 volunteer subjects underwent a full ophthalmologic examination, visual field testing using a Humphrey Field Analyzer, fundus photography, red-free SLO imaging, spectral-domain optical coherence tomography, and imaging with an original prototype AO SLO system. The AO SLO images showed many hyperreflective bundles suggesting nerve fiber bundles. In glaucomatous eyes, the nerve fiber bundles were narrower than in normal eyes, and the nerve fiber layer thickness was correlated with the nerve fiber bundle widths on AO SLO (P < .001). In the nerve fiber layer defect area on fundus photography, the nerve fiber bundles on AO SLO were narrower compared with those in normal eyes (P < .001). At 60 degrees on the inferior temporal side of the optic disc, the nerve fiber bundle width was significantly lower, even in areas without nerve fiber layer defect, in eyes with glaucomatous eyes compared with normal eyes (P = .026). The mean deviations of each cluster in visual field testing were correlated with the corresponding nerve fiber bundle widths (P = .017). AO SLO images showed reduced nerve fiber bundle widths both in clinically normal and abnormal areas of glaucomatous eyes, and these abnormalities were associated with visual field defects, suggesting that AO SLO may be useful for detecting early nerve fiber bundle abnormalities associated with loss of visual function. Copyright © 2013 Elsevier Inc. All rights reserved.
Yang, Hongli; Downs, J. Crawford; Burgoyne, Claude F.
2009-01-01
Purpose To characterize physiologic inter-eye differences in optic nerve head (ONH) architecture within six normal rhesus monkeys and compare them to inter-eye differences within three previously-reported cynomolgus monkeys with early experimental glaucoma (EEG). Methods Trephinated ONH and peripapillary sclera from both eyes of six normal monkeys were serial sectioned, 3D reconstructed, 3D delineated and parameterized. For each normal animal, and each parameter, physiologic inter-eye difference (PID) was calculated (both overall and regionally) by converting all OS data to OD configuration and subtracting the OS from the OD value and Physiologic Inter-eye Percent Difference (PIPD) was calculated as the PID divided by the measurement mean of the two eyes. For each EEG monkey, inter-eye (EEG minus normal) differences and percent differences for each parameter overall and regionally were compared to the PID and PIPD Maximums. Results For all parameters the PID Maximums were relatively small overall. Compared to overall PID maximums, overall inter-eye differences in EEG monkeys were greatest for laminar deformation and thickening, posterior scleral canal enlargement, cupping and prelaminar neural tissue thickening. Compared to the regional PID Maximums, the lamina cribrosa was posteriorly deformed centrally, inferiorly, inferonasally and superiorly and was thickened centrally. The prelaminar neural tissues were thickened inferiorly, inferonasally and superiorly. Conclusion These data provide the first characterization of PID/PIPD maximums for ONH neural and connective tissue parameters in normal monkeys and serve to further clarify the location and character of early ONH change in experimental glaucoma. However, because of the species differences, the findings in EEG need to be confirmed within EEG rhesus monkey eyes. PMID:18775866
The Effect of Ocular Surface Regularity on Contrast Sensitivity and Straylight in Dry Eye.
Koh, Shizuka; Maeda, Naoyuki; Ikeda, Chikako; Asonuma, Sanae; Ogawa, Mai; Hiraoka, Takahiro; Oshika, Tetsuro; Nishida, Kohji
2017-05-01
To investigate the association between visual function and ocular surface regularity in dry eye. We enrolled 52 eyes of 52 dry eye patients (34 dry eyes with superficial punctate keratopathy [SPK] in the central corneal region [central SPK] and 18 dry eyes without central SPK) and 20 eyes of 20 normal control subjects. All eyes had a best-corrected distance visual acuity better than 20/20. We measured two indices of contrast sensitivity function under photopic conditions: contrast sensitivity and letter contrast sensitivity. The area under the log contrast sensitivity function (AULCSF) was calculated from the obtained contrast sensitivity data. Straylight was quantified using a straylight meter. Dry eyes with central SPK had significantly decreased contrast sensitivity function, including AULCSF and letter contrast sensitivity than those without central SPK and normal eyes (P < 0.05 for each). While the straylight values in both dry eye groups did not differ, straylight values were greater than those in normal eyes (P < 0.05 for both). In dry eye, the AULCSF and letter contrast sensitivity negatively correlated with the central SPK score (R = -0.485, P < 0.001, and R = -0.541, P < 0.001, respectively). In dry eye, reduced contrast sensitivity in part results from central SPK overlying the optical zone and the increased straylight results from tear film instability rather than central SPK.
Petterssen, Max; Eljamel, Sarah; Eljamel, Sam
2014-09-01
Protoporphyrin-IX (Pp-IX) fluorescence had been used frequently in recent years to guide microsurgical resection of high-grade gliomas (HGG), particularly following the publication of a randomized controlled trial demonstrating its advantages. However, Pp-IX fluorescence is dependent upon the surgeons' eyes' perception of red fluorescent colour. This study was designed to evaluate human eye fluorescence perception and establish a fluorescence scale. 20 of 108 pre-recorded images from intraoperative fluorescence of HGG were used to construct an 8-panel visual analogue fluorescence scale. The scale was validated by testing 56 participants with normal colour vision and three red-green colour-blind participants. For intra-rater agreement ten participants were tested twice and for inter-observer reliability the whole cohort were tested. The intra- and inter-observer reliability of the scale in normal colour vision participants was excellent. The scale was less reliable in the violet-blue panels of the scale. Colour-blind participants were not able to distinguish between red fluorescence and blue-violet colours. The 8-panel fluorescence scale is valid in differentiating red, pink and blue colours in a fluorescence surgical field among participants with normal colour perception and potentially useful to standardize fluorescence-guided surgery. However, colourblind surgeons should not use fluorescence-guided surgery. Copyright © 2014 Elsevier B.V. All rights reserved.
Limitations of an ocular surface inflammatory biomarker in impression cytology specimens.
Yafawi, Rolla; Ko, Mira; Sace, Frederick P; John-Baptiste, Annette
2013-03-01
A number of ocular conditions, such as dry eye, are associated with inflammation on the surface of the eye leading to irritation and ocular pain. Many drugs such as chemotherapeutics, beta blockers, angiotensin-converting enzymes and so forth also cause dry eye but currently there are no validated ocular surface biomarkers available. We evaluated sample stability, assay sensitivity, reproducibility and overall performance of impression cytology (IC) utilizing the cellular surface biomarker human leukocyte antigen DR-1 (HLA-DR) as an ocular surface inflammatory biomarker by flow cytometry in a fit-for-purpose validation study. Additionally, subjects classified as normal or having various degrees of dry eye were evaluated to determine if HLA-DR could demonstrate a clear separation between normal and dry eye samples. The assay demonstrated high dynamic range detecting a broad range of fluorescent intensities in healthy donors. Additionally, inter, intra and stability assay results demonstrated strong concordance and low variability. Overall CV% for both assays were less than 25% for all measured parameters. However, high variability was observed for donor samples assayed beyond day 10 post IC sample collection (4.2-110.8 CV%). HLA-DR expression demonstrated a progressive increase in patients with mild to severe levels of dry eye disease providing sufficient evidence it is sensitive enough to monitor inflammatory effects of dry eye when coupled with additional biomarkers and/or methodologies such as cytokine analysis or ICAM-1. This biomarker can be used to monitor ocular surface disorders in patients and to evaluate potential treatment options during drug development. Although our results demonstrate this methodology is reproducible for routine evaluation, limitations around sample integrity exist. The ocular cell surface inflammatory biomarker, HLA-DR coupled with impression cytology is a simple non-invasive robust, specific and reproducible assay that can be utilized to measure inflammatory infiltrates on the surface of the eye in IC samples less than 10-days old.
Wong, Bernice H; Chan, Jia Pei; Cazenave-Gassiot, Amaury; Poh, Rebecca W; Foo, Juat Chin; Galam, Dwight L A; Ghosh, Sujoy; Nguyen, Long N; Barathi, Veluchamy A; Yeo, Sia W; Luu, Chi D; Wenk, Markus R; Silver, David L
2016-05-13
Eye photoreceptor membrane discs in outer rod segments are highly enriched in the visual pigment rhodopsin and the ω-3 fatty acid docosahexaenoic acid (DHA). The eye acquires DHA from blood, but transporters for DHA uptake across the blood-retinal barrier or retinal pigment epithelium have not been identified. Mfsd2a is a newly described sodium-dependent lysophosphatidylcholine (LPC) symporter expressed at the blood-brain barrier that transports LPCs containing DHA and other long-chain fatty acids. LPC transport via Mfsd2a has been shown to be necessary for human brain growth. Here we demonstrate that Mfsd2a is highly expressed in retinal pigment epithelium in embryonic eye, before the development of photoreceptors, and is the primary site of Mfsd2a expression in the eye. Eyes from whole body Mfsd2a-deficient (KO) mice, but not endothelium-specific Mfsd2a-deficient mice, were DHA-deficient and had significantly reduced LPC/DHA transport in vivo Fluorescein angiography indicated normal blood-retinal barrier function. Histological and electron microscopic analysis indicated that Mfsd2a KO mice exhibited a specific reduction in outer rod segment length, disorganized outer rod segment discs, and mislocalization of and reduction in rhodopsin early in postnatal development without loss of photoreceptors. Minor photoreceptor cell loss occurred in adult Mfsd2a KO mice, but electroretinography indicated visual function was normal. The developing eyes of Mfsd2a KO mice had activated microglia and up-regulation of lipogenic and cholesterogenic genes, likely adaptations to loss of LPC transport. These findings identify LPC transport via Mfsd2a as an important pathway for DHA uptake in eye and for development of photoreceptor membrane discs. © 2016 by The American Society for Biochemistry and Molecular Biology, Inc.
PSF and MTF comparison of two different surface ablation techniques for laser visual correction
NASA Astrophysics Data System (ADS)
Cruz Félix, Angel Sinue; López Olazagasti, Estela; Rosales, Marco A.; Ibarra, Jorge; Tepichín Rodríguez, Eduardo
2009-08-01
It is well known that the Zernike expansion of the wavefront aberrations has been extensively used to evaluate the performance of image forming optical systems. Recently, these techniques were adopted in the field of Ophthalmology to evaluate the objective performance of the human ocular system. We have been working in the characterization and evaluation of the performance of normal human eyes; i.e., eyes which do not require any refractive correction (20/20 visual acuity). These data provide us a reference model to analyze Pre- and Post-Operated results from eyes that have been subjected to laser refractive surgery. Two different ablation techniques are analyzed in this work. These techniques were designed to correct the typical refractive errors known as myopia, hyperopia, and presbyopia. When applied to the corneal surface, these techniques provide a focal shift and, in principle, an improvement of the visual performance. These features can be suitably described in terms of the PSF and MTF of the corresponding Pre- and Post-Operated wavefront aberrations. We show the preliminary results of our comparison.
Electrical Microstimulation of the Superior Colliculus in Strabismic Monkeys.
Fleuriet, Jérome; Walton, Mark M G; Ono, Seiji; Mustari, Michael J
2016-06-01
Visually guided saccades are disconjugate in human and nonhuman strabismic primates. The superior colliculus (SC) is a region of the brain topographically organized in visual and motor maps where the saccade goal is spatially coded. The present study was designed to investigate if a site of stimulation on the topographic motor map was evoking similar or different saccade vectors for each eye. We used microelectrical stimulation (MS) of the SC in two strabismic (one esotrope and one exotrope) and two control macaques under binocular and monocular viewing conditions. We compared the saccade amplitudes and directions for each SC site and each condition independently of the fixating eye and then between each fixating eye. A comparison with disconjugacies of visually guided saccades was also performed. We observed different saccade vectors for the two eyes in strabismic monkeys, but conjugate saccades in normal monkeys. Evoked saccade vectors for the left eye when that eye was fixating the target were different from those of the right eye when it was fixating. The disconjugacies evoked by the MS were not identical but similar to those observed for visually guided saccades especially for the dominant eye. Our results suggest that, in strabismus, the saccade generator does not interpret activation of a single location of the SC as the same desired displacement for each eye. This finding is important for advancing understanding of the development of neural circuits in strabismus. French Abstract.
Basigin/EMMPRIN/CD147 mediates neuron-glia interactions in the optic lamina of Drosophila.
Curtin, Kathryn D; Wyman, Robert J; Meinertzhagen, Ian A
2007-11-15
Basigin, an IgG family glycoprotein found on the surface of human metastatic tumors, stimulates fibroblasts to secrete matrix metalloproteases (MMPs) that remodel the extracellular matrix, and is thus also known as Extracellular Matrix MetalloPRotease Inducer (EMMPRIN). Using Drosophila we previously identified novel roles for basigin. Specifically, photoreceptors of flies with basigin eyes show misplaced nuclei, rough ER and mitochondria, and swollen axon terminals, suggesting cytoskeletal disruptions. Here we demonstrate that basigin is required for normal neuron-glia interactions in the Drosophila visual system. Flies with basigin mutant photoreceptors have misplaced epithelial glial cells within the first optic neuropile, or lamina. In addition, epithelial glia insert finger-like projections--capitate projections (CPs)--sites of vesicle endocytosis and possibly neurotransmitter recycling. When basigin is missing from photoreceptors terminals, CP formation between glia and photoreceptor terminals is disrupted. Visual system function is also altered in flies with basigin mutant eyes. While photoreceptors depolarize normally to light, synaptic transmission is greatly diminished, consistent with a defect in neurotransmitter release. Basigin expression in photoreceptor neurons is required for normal structure and placement of glia cells.
ERIC Educational Resources Information Center
Hayden, Angela; Bhatt, Ramesh S.; Reed, Andrea; Corbly, Christine R.; Joseph, Jane E.
2007-01-01
Sensitivity to second-order relational information (i.e., spatial relations among features such as the distance between eyes) is a vital part of achieving expertise with face processing. Prior research is unclear on whether infants are sensitive to second-order differences seen in typical human populations. In the current experiments, we examined…
Simulation of keratoconus observation in photorefraction
NASA Astrophysics Data System (ADS)
Chen, Ying-Ling; Tan, B.; Baker, K.; Lewis, J. W. L.; Swartz, T.; Jiang, Y.; Wang, M.
2006-11-01
In the recent years, keratoconus (KC) has increasingly gained attention due to its treatment options and to the popularity of keratorefractive surgery. This paper investigates the potential of identification of KC using photorefraction (PR), an optical technique that is similar to objective retinoscopy and is commonly used for large-scale ocular screening. Using personalized eye models of both KC and pre-LASIK patients, computer simulations were performed to achieve visualization of this ophthalmic measurement. The simulations are validated by comparing results to two sets of experimental measurements. These PR images show distinguishable differences between KC eyes and eyes that are either normal or ametropic. The simulation technique with personalized modeling can be extended to other ophthalmic instrument developments. It makes possible investigation with the least number of real human subjects. The application is also of great interest in medical training.
Ashtari, Manzar; Zhang, Hui; Cook, Philip A.; Cyckowski, Laura L.; Shindler, Kenneth S.; Marshall, Kathleen A.; Aravand, Puya; Vossough, Arastoo; Gee, James C.; Maguire, Albert M.; Baker, Chris I.; Bennett, Jean
2015-01-01
Much of our knowledge of the mechanisms underlying plasticity in the visual cortex in response to visual impairment, vision restoration, and environmental interactions comes from animal studies. We evaluated human brain plasticity in a group of patients with Leber’s congenital amaurosis (LCA), who regained vision through gene therapy. Using non-invasive multimodal neuroimaging methods, we demonstrated that reversing blindness with gene therapy promoted long-term structural plasticity in the visual pathways emanating from the treated retina of LCA patients. The data revealed improvements and normalization along the visual fibers corresponding to the site of retinal injection of the gene therapy vector carrying the therapeutic gene in the treated eye compared to the visual pathway for the untreated eye of LCA patients. After gene therapy, the primary visual pathways (for example, geniculostriate fibers) in the treated retina were similar to those of sighted control subjects, whereas the primary visual pathways of the untreated retina continued to deteriorate. Our results suggest that visual experience, enhanced by gene therapy, may be responsible for the reorganization and maturation of synaptic connectivity in the visual pathways of the treated eye in LCA patients. The interactions between the eye and the brain enabled improved and sustained long-term visual function in patients with LCA after gene therapy. PMID:26180100
NASA Astrophysics Data System (ADS)
Chen, Yi-Chun; Jiang, Chong-Jhih; Yang, Tsung-Hsun; Sun, Ching-Cherng
2012-07-01
A biometry-based human eye model was developed by using the empirical anatomic and optical data of ocular parameters. The gradient refractive index of the crystalline lens was modeled by concentric conicoid isoindical surfaces and was adaptive to accommodation and age. The chromatic dispersion of ocular media was described by Cauchy equations. The intraocular scattering model was composed of volumetric Mie scattering in the cornea and the crystalline lens, and a diffusive-surface model at the retina fundus. The retina was regarded as a Lambertian surface and was assigned its corresponding reflectance at each wavelength. The optical performance of the eye model was evaluated in CodeV and ASAP and presented by the modulation transfer functions at single and multiple wavelengths. The chromatic optical powers obtained from this model resembled that of the average physiological eyes. The scattering property was assessed by means of glare veiling luminance and compared with the CIE general disability glare equation. By replacing the transparent lens with a cataractous lens, the disability glare curve of cataracts was generated to compare with the normal disability glare curve. This model has high potential for investigating visual performance in ordinary lighting and display conditions and under the influence of glare sources.
Magnetic resonance imaging study of eye congenital birth defects in mouse model
Tucker, Zachary; Mongan, Maureen; Meng, Qinghang; Xia, Ying
2017-01-01
Purpose Embryonic eyelid closure is a well-documented morphogenetic episode in mammalian eye development. Detection of eyelid closure defect in humans is a major challenge because eyelid closure and reopen occur entirely in utero. As a consequence, congenital eye defects that are associated with failure of embryonic eyelid closure remain unknown. To fill the gap, we developed a mouse model of defective eyelid closure. This preliminary work demonstrates that the magnetic resonance imaging (MRI) approach can be used for the detection of extraocular muscle abnormalities in the mouse model. Methods Mice with either normal (Map3k1+/−) or defective (Map3k1−/−) embryonic eyelid closure were used in this study. Images of the extraocular muscles were obtained with a 9.4 T high resolution microimaging MRI system. The extraocular muscles were identified, segmented, and measured in each imaging slice using an in-house program. Results In agreement with histological findings, the imaging data show that mice with defective embryonic eyelid closure develop less extraocular muscle than normal mice. In addition, the size of the eyeballs was noticeably reduced in mice with defective embryonic eyelid closure. Conclusions We demonstrated that MRI can potentially be used for the study of extraocular muscle in the mouse model of the eye open-at-birth defect, despite the lack of specificity of muscle group provided by the current imaging resolution. PMID:28848319
Baker, Daniel H; Meese, Tim S; Hess, Robert F
2008-07-01
To investigate amblyopic contrast vision at threshold and above we performed pedestal-masking (contrast discrimination) experiments with a group of eight strabismic amblyopes using horizontal sinusoidal gratings (mainly 3c/deg) in monocular, binocular and dichoptic configurations balanced across eye (i.e. five conditions). With some exceptions in some observers, the four main results were as follows. (1) For the monocular and dichoptic conditions, sensitivity was less in the amblyopic eye than in the good eye at all mask contrasts. (2) Binocular and monocular dipper functions superimposed in the good eye. (3) Monocular masking functions had a normal dipper shape in the good eye, but facilitation was diminished in the amblyopic eye. (4) A less consistent result was normal facilitation in dichoptic masking when testing the good eye, but a loss of this when testing the amblyopic eye. This pattern of amblyopic results was replicated in a normal observer by placing a neutral density filter in front of one eye. The two-stage model of binocular contrast gain control [Meese, T.S., Georgeson, M.A. & Baker, D.H. (2006). Binocular contrast vision at and above threshold. Journal of Vision 6, 1224-1243.] was 'lesioned' in several ways to assess the form of the amblyopic deficit. The most successful model involves attenuation of signal and an increase in noise in the amblyopic eye, and intact stages of interocular suppression and binocular summation. This implies a behavioural influence from monocular noise in the amblyopic visual system as well as in normal observers with an ND filter over one eye.
Ocular counterrolling measured during eight hours of sustained body tilt
NASA Technical Reports Server (NTRS)
Miller, E. F., II; Graybiel, A.
1972-01-01
Adaptation of otolith organ activity was investigated by monitoring the ocular counterrolling response of four normal individuals and three persons with severe bilateral loss of labyrinthine function. Several eye photographs were recorded every 30 minutes during a period of 8 hours in which the subject was held in a lateral tilt (60 deg) position. The recorded eye roll position varied to an expected small extent within each test session; this variation about a given mean roll position was similar among the test sessions for all subjects. The mean roll position, on the other hand, changed from session to session in substantial amounts, but these changes appeared to be random with respect to time and among subjects. Furthermore, the intersessional variation in the mean torsional eye position of the normal subjects was equivalent to that of the labyrinthine-defective subjects who displayed little or no counterrolling. These results suggest that the human counterrolling response is maintained either by essentially nonadapting macular receptors or by extremely fine movements of the head in the gravitational field, such as may have been allowed by the biteboard/headrest restraint system used in this study, which served as an everchanging accelerative stimulus.
Anastasopoulos, D; Mandellos, D; Kostadima, V; Pettorossi, V E
2002-08-01
We studied the amplitude, latency, and probability of occurrence of fast phases (FP) in darkness to unpredictable vestibular and/or cervical yaw stimulation in normal human subjects. The rotational stimuli were smoothed trapezoidal motion transients of 14 degrees amplitude and 1.25 s duration. Eye position before stimulus application (initial eye position, IEP) was introduced as a variable by asking the subjects to fixate a spot appearing either straight ahead or at 7 degrees eccentric positions. The recordings demonstrated that the generation of FP during vestibular stimulation was facilitated when the whole-body rotation was directed opposite the eccentric IEP. Conversely, FP were attenuated if the whole-body rotation was directed toward the eccentric IEP; i.e., the FP attenuated if they were made to further eccentric positions. Cervical stimulation-induced FP were small and variable in direction when IEP was directed straight ahead before stimulus onset. Eccentric IEPs resulted in large FP, the direction of which was essentially independent of the neck-proprioceptive stimulus. They tended to move the eye toward the primary position, both when the trunk motion under the stationary head was directed toward or away from the IEP. FP dependence on IEP was evident also during head-on-trunk rotations. No consistent interaction between vestibularly and cervically induced FP was found. We conclude that extraretinal eye position signals are able to modify vestibularly evoked reflexive FP in darkness, aiming at minimizing excursions of the eyes away from the primary position. However, neck-induced FP do not relate to specific tasks of stabilization or visual search. By keeping the eyes near the primary position, FP may permit flexibility of orienting responses to incoming stimuli. This recentering bias for both vestibularly and cervically generated FP may represent a visuomotor optimizing strategy.
Human short-latency ocular vergence responses produced by interocular velocity differences
Sheliga, B. M.; Quaia, C.; FitzGibbon, E. J.; Cumming, B. G.
2016-01-01
We studied human short-latency vergence eye movements to a novel stimulus that produces interocular velocity differences without a changing disparity signal. Sinusoidal luminance gratings moved in opposite directions (left vs. right; up vs. down) in the two eyes. The grating seen by each eye underwent ¼-wavelength shifts with each image update. This arrangement eliminated changing disparity cues, since the phase difference between the eyes alternated between 0° and 180°. We nevertheless observed robust short-latency vergence responses (VRs), whose sign was consistent with the interocular velocity differences (IOVDs), indicating that the IOVD cue in isolation can evoke short-latency VRs. The IOVD cue was effective only when the images seen by the two eyes overlapped in space. We observed equally robust VRs for opposite horizontal motions (left in one eye, right in the other) and opposite vertical motions (up in one eye, down in the other). Whereas the former are naturally generated by objects moving in depth, the latter are not part of our normal experience. To our knowledge, this is the first demonstration of a behavioral consequence of vertical IOVD. This may reflect the fact that some neurons in area MT are sensitive to these motion signals (Czuba, Huk, Cormack, & Kohn, 2014). VRs were the strongest for spatial frequencies in the range of 0.35–1 c/°, much higher than the optimal spatial frequencies for evoking ocular-following responses observed during frontoparallel motion. This suggests that the two motion signals are detected by different neuronal populations. We also produced IOVD using moving uncorrelated one-dimensional white-noise stimuli. In this case the most effective stimuli have low speed, as predicted if the drive originates in neurons tuned to high spatial frequencies (Sheliga, Quaia, FitzGibbon, & Cumming, 2016). PMID:27548089
2003-01-22
ProVision Technologies, a NASA research partnership center at Sternis Space Center in Mississippi, has developed a new hyperspectral imaging (HSI) system that is much smaller than the original large units used aboard remote sensing aircraft and satellites. The new apparatus is about the size of a breadbox. HSI may be useful to ophthalmologists to study and diagnose eye health, both on Earth and in space, by examining the back of the eye to determine oxygen and blood flow quickly and without any invasion. ProVision's hyperspectral imaging system can scan the human eye and produce a graph showing optical density or light absorption, which can then be compared to a graph from a normal eye. Scans of the macula, optic disk or optic nerve head, and blood vessels can be used to detect anomalies and identify diseases in this delicate and important organ. ProVision has already developed a relationship with the University of Alabama at Birmingham, but is still on the lookout for a commercial partner in this application.
2003-01-22
ProVision Technologies, a NASA commercial space center at Sternis Space Center in Mississippi, has developed a new hyperspectral imaging (HSI) system that is much smaller than the original large units used aboard remote sensing aircraft and satellites. The new apparatus is about the size of a breadbox. HSI may be useful to ophthalmologists to study and diagnose eye health, both on Earth and in space, by examining the back of the eye to determine oxygen and blood flow quickly and without any invasion. ProVision's hyperspectral imaging system can scan the human eye and produce a graph showing optical density or light absorption, which can then be compared to a graph from a normal eye. Scans of the macula, optic disk or optic nerve head, and blood vessels can be used to detect anomalies and identify diseases in this delicate and important organ. ProVision has already developed a relationship with the University of Alabama at Birmingham, but is still on the lookout for a commercial partner in this application.
Chen, Hsin-Yi; Huang, Mei-Ling; Huang, Wei-Cheng
2010-01-01
Purpose To study the capability of scanning laser polarimetry with variable corneal compensation (GDx VCC) to detect differences in retinal nerve fiber layer thickness between normal and glaucomatous eyes in a Taiwan Chinese population. Methods This study included 44 normal eyes and 107 glaucomatous eyes. The glaucomatous eyes were divided into three subgroups on the basis of its visual field defects (early, moderate, severe). Each subject underwent a GDx-VCC exam and visual field testing. The area under the receiver-operating characteristic curve (AROC) of each relevant parameter was used to differentiate normal from each glaucoma subgroup, respectively. The correlation between visual field index and each parameter was evaluated for the eyes in the glaucoma group. Results For normal vs. early glaucoma, the parameter with the best AROC was Nerve fiber indicator (NFI) (0.942). For normal vs. moderate glaucoma, the parameter showing the best AROC was NFI (0.985). For normal vs. severe glaucoma, the parameter that had the best AROC was NFI (1.000). For early vs. moderate glaucoma, the parameter with the best AROC was NFI (0.732). For moderate vs. severe, the parameter showing the best AROC was temporal-superior-nasal-inferior-temporal average (0.652). For early vs. severe, the parameter with the best AROC was NFI (0.852). Conclusions GDx-VCC-measured parameters may serve as a useful tool to distinguish normal from glaucomatous eyes; in particular, NFI turned out to be the best discriminating parameter.
NASA Astrophysics Data System (ADS)
Li, Yan; Tan, Ou; Huang, David
2011-03-01
The detection of early-stage keratoconus is one of the most important safety issues in screening candidates for corneal refractive surgeries. We propose to use epithelial thickness maps to assist the diagnosis of keratoconus. The corneal epithelial thickness in normal and keratoconic eyes was mapped with optical coherence tomography (OCT). A Fourier-domain OCT system capable of acquiring 26,000 axial-scans per second was used. It has an axial resolution of 5μm in cornea. A pachymetry scan pattern (8 radials, 1024 axial-scans each, 6mm diameter, repeat 3 times) centered at the pupil center was used to image the cornea. The 3 repeated radial scans on each meridian were registered and averaged. Then the anterior corneal, posterior corneal and epithelial boundaries were segmented automatically with a computer algorithm by increased signal intensity at corresponding boundaries. The epithelial thickness map was generated by interpolating epithelial thickness profile calculated from each meridian. Normal and keratoconic eyes (24 eyes each) were scanned 3 times. The central epithelial thickness in normal eyes was thicker than those of keratoconic eyes (mean difference 2.1 μm, t-test p=0.05). The epithelium was thinner superiorly than inferiorly in normal eyes (mean difference -1.4+/-1.1μm, p<0.001) while thicker superiorly than inferiorly in keratoconic eyes (2.0+/-4.1 μm, p=0.02).
Hagiwara, Y; Yamamoto, T; Kitazawa, Y
2000-03-01
We investigated in a prospective fashion the visual prognosis and complications in normal-tension glaucoma following unilateral trabeculectomy with adjunctive mitomycin C. Trabeculectomy with adjunctive mitomycin C was carried out unilaterally in 21 cases of normal-tension glaucoma. Intraocular pressure (IOP), visual prognosis, and complications were compared between the operated eyes and the non-operated fellow eyes. The follow-up period ranged from 2 to 7 years. The IOP dropped significantly from 14.8+/-1.8 mmHg (mean +/- SD) to 9.6+/-3.9 mmHg in the operated eyes (P=0.0002, Wilcoxon signed-rank test), but did not drop in the non-operated eyes. The mean deviation (MD) was -12.69+/-6.41 dB preoperatively and -14.70+/-5.49 dB at the last clinic visit in the operated eyes, whereas in non-operated eyes it was -7.85+/-5.65 dB and -11.15+/-5.62 dB, respectively. The MD deteriorated significantly in both operated and non-operated eyes (operated eyes P=0.0239, non-operated eyes: P=0.0002; Wilcoxon signed-rank test). The MD slope was -0.37+/-0.60 dB/year and -0.71+/-0.89 dB/year for the operated and non-operated eyes, respectively (P=0.5243, Mann-Whitney U-test). Visual field deterioration was more frequently observed in the non-operated eyes by a pointwise definition of the progression (P<0.05, McNemar test). Visual acuity deteriorated in 6 of the operated eyes and in 5 of the non-operated eyes. Cataract developed in 6 (29%) of the 21 operated eyes, while among the non-operated eyes 4 (19%) developed cataract. Mitomycin C trabeculectomy is effective in delaying progression of visual field defect in normal-tension glaucoma, but complications may arise and cause some visual disturbance.
Stahl, John S; Oommen, Brian S
2008-01-01
Humans with cerebellar degeneration commonly exhibit downbeat nystagmus (DBN). DBN has gravity-independent and -dependent components, and the latter has been proposed to reflect hyperactive tilt maculo-ocular reflexes (tilt-MOR). Mice with genetically determined cerebellar ataxia do not exhibit DBN, but they do exhibit tonic hyperdeviation of the eyes, which we have proposed to be the DBN equivalent. As such, the tilt-MOR might be predicted to be hyperactive in these mutant mice. We measured the tilt-MOR in 10 normal C57BL/6 mice and in 6 tottering, a mutant exhibiting ataxia and ocular motor abnormalities due to mutation of the P/Q calcium channel. Awake mice were placed in body orientations spanning 360 degrees about the pitch axis. The absolute, equilibrium vertical angular deviations of one eye were measured using infrared videooculography. In both strains, eye elevation varied quasi-sinusoidally with tilt angle in the range of 90 degrees nose-up to 90 degrees nose-down. Beyond this range the eye returned to a neutral position. Deviation over +/-30 degrees of tilt was an approximately linear function of the projection of the gravity vector into the animal's horizontal plane, and can thus be summarized by its slope (sensitivity). Sensitivity measured 14.9 degrees/g for C57BL/6 and 20.3 degrees/g for tottering, a statistically significant difference. Thus the pitch otolithic reflex of the ataxic mutants is hyperactive relative to controls and could explain tonic hyperdeviation of the eyes, consistent with the idea that the tonic hyperdeviation is analogous to DBN.
Temporal dynamics of ocular position dependence of the initial human vestibulo-ocular reflex.
Crane, Benjamin T; Tian, Junru; Demer, Joseph L
2006-04-01
While an ideal vestibulo-ocular reflex (VOR) generates ocular rotations compensatory for head motion, during visually guided movements, Listing's Law (LL) constrains the eye to rotational axes lying in Listing's Plane (LP). The present study was conducted to explore the recent proposal that the VOR's rotational axis is not collinear with the head's, but rather follows a time-dependent strategy intermediate between LL and an ideal VOR. Binocular LPs were defined during visual fixation in eight normal humans. The VOR was evoked by a highly repeatable transient whole-body yaw rotation in darkness at a peak acceleration of 2800 deg/s2. Immediately before rotation, subjects regarded targets 15 or 500 cm distant located at eye level, 20 degrees up, or 20 degrees down. Eye and head responses were compared with LL predictions in the position and velocity domains. LP orientation varied both among subjects and between individual subject's eyes, and rotated temporally with convergence by 5 +/- 5 degrees (+/-SEM). In the position domain, the eye compensated for head displacement even when the head rotated out of LP. Even within the first 20 ms from onset of head rotation, the ocular velocity axis tilted relative to the head axis by 30% +/- 8% of vertical gaze position. Saccades increased this tilt. Regardless of vertical gaze position, the ocular rotation axis tilted backward 4 degrees farther in abduction than in adduction. There was also a binocular vertical eye velocity transient and lateral tilt of the ocular axis. These disconjugate, short-latency axis perturbations appear intrinsic to the VOR and may have neural or mechanical origins.
Chen, Chieh-Li; Bojikian, Karine D; Wen, Joanne C; Zhang, Qinqin; Xin, Chen; Mudumbai, Raghu C; Johnstone, Murray A; Chen, Philip P; Wang, Ruikang K
2017-05-01
Understanding the differences in vascular microcirculation of the peripapillary retinal nerve fiber layer (RNFL) between the hemispheres in eyes with glaucoma with single-hemifield visual field (VF) defects may provide insight into the pathophysiology of glaucoma. To investigate the changes in the microcirculation of the peripapillary RNFL of eyes with glaucoma by using optical microangiography. Eyes with glaucoma and single-hemifield VF defect and normal eyes underwent scanning using an optical microangiography system covering a 6.7 × 6.7-mm2 area centered at the optic nerve head. The RNFL microcirculation was measured within an annulus region centered at the optic nerve head divided into superior and inferior hemispheres. Blood flux index (the mean flow signal intensity in the vessels) and vessel area density (the percentage of the detected vessels in the annulus) were measured. Differences in microcirculation between the hemispheres in eyes with glaucoma and normal eyes and correlations among blood flow metrics, VF thresholds, and clinical optical coherence tomography structural measurements were assessed. Twenty-one eyes from 21 patients with glaucoma (7 men and 14 women; mean [SD] age, 63.7 [9.9] years) and 20 eyes from 20 healthy control individuals (9 men and 11 women; mean [SD] age, 68.3 [10.7] years) were studied. In eyes with glaucoma, the abnormal hemisphere showed a thinner RNFL (mean [SE] difference, 23.5 [4.5] μm; 95% CI, 15.1-32.0 µm; P < .001), lower RNFL blood flux index (mean [SE] difference, 0.04 [0.01]; 95% CI, 0.02-0.05; P < .001), and less vessel area density (mean [SE] difference, 0.08% [0.02%]; 95% CI, 0.05%-0.10%; P < .001) than did the normal hemisphere. Compared with normal eyes, reduced RNFL microcirculation was found in the normal hemisphere of eyes with glaucoma, measured by mean [SE] differences in blood flux index (0.06 [0.01]; 95% CI, 0.04-0.09; P < .001) and vessel area density (0.04% [0.02%]; 95% CI, 0.02%-0.08%; P = .003) but not in RNFL thickness (3.4 [4.7] μm; 95% CI, -6.2 to 12.9 µm; P = .48). Strong correlations were found between the blood flux index and VF mean deviation (Spearman ρ = 0.44; P = .045) and RNFL thickness (Spearman ρ = 0.65; P = .001) in the normal hemisphere of the eye with glaucoma. Reduced RNFL microcirculation was detected in the normal hemisphere of eyes with glaucoma, with strong correspondence with VF loss and RNFL thinning. Although the results suggest that vascular dysfunction precedes structural changes seen in glaucoma, longitudinal studies would be needed to confirm this finding.
Fan, X; Wu, L L; Xiao, G G; Ma, Z Z; Liu, F
2018-03-11
Objective: To analyze potentials of frequency-doubling technology perimetry (FDP) for diagnosing open-angle glaucoma (OAG) in perimetrically normal eyes of OAG patients diagnosed with standard automated perimetry (SAP) and relating factors from abnormalities on FDP to visual field loss on SAP. Methods: A prospective cohort study. Sixty-eight eyes of 68 OAG patients visiting the ophthalmic clinic of Peking University Third Hospital during November 2003 and October 2007 [32 primary open-angle glaucoma patients and 36 normal tension glaucoma patients, 32 males and 36 females, with an average age of (59±13) years] with unilateral field loss detected by SAP (Octopus101 tG2 program) were examined with the FDP N-30 threshold program (Humphrey Instruments) at baseline. Two groups, FDP positive group and FDP negative group, were divided based on the FDP results, and visual field examinations were followed by a series of SAP examinations for the perimetrically normal eyes over 8 years. During the follow-up, the difference of the converting rate of SAP tests between the two groups was analyzed. Differences between "convertors" and "non-convertors" of SAP tests in the FDP positive group, such as the cup-to-disk ratio and glaucomatous optic neuropathy rate, were also compared with the independent-sample t test or Wilcoxon two-sample test for continuous variable data and the χ(2) test or Fisher exact test for classified variable data and rates. Results: Forty-eight perimetrically normal eyes of 48 participants had complete data and a qualifying follow-up. Baseline FDP results were positive in 33 eyes and negative in 15 eyes. Of the eyes with positive FDP results, 22 eyes developed abnormal SAP results after 4.0 to 90.0 months (median 14.5 months) , whereas none of the eyes with negative FDP results developed abnormal SAP results. For perimetrically normal eyes in the FDP positive group, "converters" showed a greater cup-to-disk ratio (0.73±0.09 vs . 0.63±0.14, Wilcoxon two-sample test, P= 0.011) and more eyes with glaucomatous optic neuropathy (19/22 vs . 4/11, Fisher exact test, P= 0.006). Conclusions: In perimetrically normal eyes of OAG patients, FDP could detect visual field loss of these eyes and predict to some extent future visual field loss on SAP. Severity of glaucomatous optic neuropathy at baseline is related to converting from abnormalities on FDP to visual field loss on SAP. (Chin J Ophthalmol, 2018, 54: 177-183) .
Successful gene therapy in the RPGRIP1-deficient dog: a large model of cone-rod dystrophy.
Lhériteau, Elsa; Petit, Lolita; Weber, Michel; Le Meur, Guylène; Deschamps, Jack-Yves; Libeau, Lyse; Mendes-Madeira, Alexandra; Guihal, Caroline; François, Achille; Guyon, Richard; Provost, Nathalie; Lemoine, Françoise; Papal, Samantha; El-Amraoui, Aziz; Colle, Marie-Anne; Moullier, Philippe; Rolling, Fabienne
2014-02-01
For the development of new therapies, proof-of-concept studies in large animal models that share clinical features with their human counterparts represent a pivotal step. For inherited retinal dystrophies primarily involving photoreceptor cells, the efficacy of gene therapy has been demonstrated in canine models of stationary cone dystrophies and progressive rod-cone dystrophies but not in large models of progressive cone-rod dystrophies, another important cause of blindness. To address the last issue, we evaluated gene therapy in the retinitis pigmentosa GTPase regulator interacting protein 1 (RPGRIP1)-deficient dog, a model exhibiting a severe cone-rod dystrophy similar to that seen in humans. Subretinal injection of AAV5 (n = 5) or AAV8 (n = 2) encoding the canine Rpgrip1 improved photoreceptor survival in transduced areas of treated retinas. Cone function was significantly and stably rescued in all treated eyes (18-72% of those recorded in normal eyes) up to 24 months postinjection. Rod function was also preserved (22-29% of baseline function) in four of the five treated dogs up to 24 months postinjection. No detectable rod function remained in untreated contralateral eyes. More importantly, treatment preserved bright- and dim-light vision. Efficacy of gene therapy in this large animal model of cone-rod dystrophy provides great promise for human treatment.
Hirata, Harumitsu; Rosenblatt, Mark I
2014-08-19
Tear hyperosmolarity is a ubiquitous feature of dry-eye disease. Although dry-eye patients' sensitivity to cooling is well known, the effects of tear hyperosmolarity on a small amount of cooling in the corneal nerves have not been quantitatively examined. Recently reported corneal afferents, high-threshold cold sensitive plus dry-sensitive (HT-CS + DS) neurons, in rats is normally excited by strong (>4°C) cooling of the cornea, which, when applied to healthy humans, evokes the sensation of discomfort. However, corneal cooling measured between blinks does not exceed 2°C normally. Thus, we sought to determine if these nociceptors could be sensitized by hyperosmolar tears such that they are now activated by small cooling of the ocular surface. Trigeminal ganglion neurons innervating the cornea were extracellularly recorded in isoflurane-anesthetized rats. The responses of single corneal neurons to cooling stimuli presented in the presence of hyperosmolar (350-800 mOsm NaCl) tears were examined. The HT-CS + DS neurons with thresholds averaging 4°C cooling responded to cooling stimuli presented after 15 minutes of hyperosmolar tears with thresholds of less than 1°C. The response magnitudes also were enhanced so that the responses to small (2°C) cooling emerged, where none was observed before. These results demonstrate that after exposure to hyperosmolar tears, these nociceptive corneal neurons now begin to respond to the slight cooling normally encountered between blinks, enabling the painful information to be carried to the brain, which could explain the cooling-evoked discomfort in dry eye patients. Copyright 2014 The Association for Research in Vision and Ophthalmology, Inc.
Babizhayev, Mark A
2009-01-01
Cataract is the dominant cause of blindness worldwide. Studies of the morphological structure and biophysical changes of the lens in human senile cataracts have demonstrated the disappearance of normal fiber structure in the opaque region of the lens and the disintegration of the lens fiber plasma membrane in the lens tissue. Morphological and biochemical techniques have revealed the regions in human cataractous lenses in which the plasma membrane derangement occurs as the primary light scattering centers which cause the observed lens opacity. Human cataract formation is mostly considered to be a multifactorial disease; however, oxidative stress might be one of the leading causes for both nuclear and cortical cataract. Phospholipid molecules modified with oxygen, accumulating in the lipid bilayer, change its geometry and impair lipid-lipid and protein-lipid interactions in lenticular fiber membranes. Electron microscopy data of human lenses at various stages of age-related cataract document that these disruptions were globules, vacuoles, multilamellar membranes, and clusters of highly undulating membranes. The opaque shades of cortical cataracts represent cohorts of locally affected fibres segregated from unaffected neighbouring fibres by plasma membranes. Other potential scattering centers found throughout the mature cataract nucleus included variations in staining density between adjacent cells, enlarged extracellular spaces between undulating membrane pairs, and protein-like deposits in the extracellular space. These affected parts had membranes with a fine globular aspect and in cross-section proved to be filled with medium to large globular elements. Lipid peroxidation (LPO) is a pathogenetic and causative factor of cataract. Increased concentrations of primary molecular LPO products (diene conjugates, lipid hydroperoxides, fatty acid oxy-derivatives) and end fluorescent LPO products were detected in the lipid moieties of the aqueous humor samples and human lenses obtained from patients with senile and complicated cataracts as compared to normal donors. Utilizing the pharmacokinetic studies and the specific purity N-acetylcarnosine (NAC) ingredient as a source of pharmacological principal L-carnosine, we have created an ophthalmic time-release prodrug form combined with a muco-adhesive lubricant compound carboxymethylcellulose and other essential corneal absorption promoter excipients tailoring the increased intraocular absorption of L-carnosine in the aqueous humor and optimizing its specific effect in producing the basic antioxidant activity in vivo and reducing toxic effects of lipid peroxides to the crystalline lens. L-Carnosine that finds its way into the aqueous humor can accumulate in the lens tissue for a reasonable period of time. However, administration of pure L-carnosine (1% solution) to the rabbit eye (instillation, subconjunctival injection) does not lead to accumulation of this natural compound in the aqueous humor over 30 min in concentration exceeding that in the placebo-treated matched eyes, and its effective concentration is exhausted more rapidly. The NAC prodrug eye drops optimize the clinical effects for the treatment of ophthalmic disorders (such as prevention and reversal of cataracts in human and animal [canine] eyes). The data provided predict a particular NAC ophthalmic prodrug's clinical effect; the suitable magnitude and duration of this effect suggest dose-related bioavailability of L-camosine released from NAC in the aqueous humor of the anterior eye segment. The ophthalmic NAC drug shows promise in the treatment of a range of ophthalmic disorders which have a component of oxidative stress in their genesis (including cataract and after-cataract, glaucoma, dry eye, vitreous floaters, inflammatory disorders, corneal, retinal and systemic diseases [such as diabetes mellitus and its ophthalmic complications]). The clinical efficacy of N-acetylcarnosine lubricant eye drops in ripe cataracts and retinal disorders can be enhanced in combined treatment with a patented oral formulation (Can-C Plus) of non-hydrolyzed carnosine including synergistic compounds (histidine, D-panthethine) with chaperone activity towards lens crystallins and oral supplementation with N-acetylcysteine providing an alternate means of boosting reduced glutathione (GSH) synthesis in the lens.
Cues of fatigue: effects of sleep deprivation on facial appearance.
Sundelin, Tina; Lekander, Mats; Kecklund, Göran; Van Someren, Eus J W; Olsson, Andreas; Axelsson, John
2013-09-01
To investigate the facial cues by which one recognizes that someone is sleep deprived versus not sleep deprived. Experimental laboratory study. Karolinska Institutet, Stockholm, Sweden. Forty observers (20 women, mean age 25 ± 5 y) rated 20 facial photographs with respect to fatigue, 10 facial cues, and sadness. The stimulus material consisted of 10 individuals (five women) photographed at 14:30 after normal sleep and after 31 h of sleep deprivation following a night with 5 h of sleep. Ratings of fatigue, fatigue-related cues, and sadness in facial photographs. The faces of sleep deprived individuals were perceived as having more hanging eyelids, redder eyes, more swollen eyes, darker circles under the eyes, paler skin, more wrinkles/fine lines, and more droopy corners of the mouth (effects ranging from b = +3 ± 1 to b = +15 ± 1 mm on 100-mm visual analog scales, P < 0.01). The ratings of fatigue were related to glazed eyes and to all the cues affected by sleep deprivation (P < 0.01). Ratings of rash/eczema or tense lips were not significantly affected by sleep deprivation, nor associated with judgements of fatigue. In addition, sleep-deprived individuals looked sadder than after normal sleep, and sadness was related to looking fatigued (P < 0.01). The results show that sleep deprivation affects features relating to the eyes, mouth, and skin, and that these features function as cues of sleep loss to other people. Because these facial regions are important in the communication between humans, facial cues of sleep deprivation and fatigue may carry social consequences for the sleep deprived individual in everyday life.
Kriss, Joseph P.; Mehdi, S. Qasim
1979-01-01
We prepared artificial vesicles that are lysed upon cell-mediated immunological attack by human lymphocytes. These vesicles are made from a mixture of dimyristoyl lecithin, dipalmitoyl lecithin, and cholesterol, have eye muscle membrane protein (EMP) inserted into the bilayer wall, and contain intravesicular 99mTc marker. Injury to the vesicular membrane was assessed by measurement of 99mTc release. Thyroglobulin (Tg) and Tg-anti-Tg complex (TgA) bind to EMP-vesicles to an extent equal to or greater than to native eye muscle membranes in vitro; this binding requires the presence of normal human IgG. The role of Tg, TgA, IgG, and peripheral blood lymphocytes in altering membrane permeability was analyzed. Incubation of vesicles for up to 3 hr alone, with added IgG alone, or with further addition of Tg or TgA did not result in 99mTc release. Addition of lymphocytes from normal donors to the above four preparations showed release in the presence of TgA. Lymphocytes from each of eight patients with Graves ophthalmopathy caused release not only in the presence of TgA, but also in the presence of Tg. Separation of a patient's lymphocytes into high- and low-affinity rosette-formers (T and K cells, respectively) showed that cell-mediated vesicle lysis in the presence of TgA was greater with K cells than with T cells, while vesicle lysis in the presence of Tg was greater with T cells than with K cells. Vesicles made with inserted Tg but lacking EMP were not lysed by such T cells. Lymphocytes failed to induce permeability changes in vesicles containing other inserted proteins obtained from human nonextraocular muscle, liver, spleen, or adrenal, even if Tg or TgA were present. The results support the concept that muscle cell damage in Graves ophthalmopathy is immunological, cell-mediated, and of two types: (i) K lymphocytes reacting to immune complex, TgA, on the eye muscle cell surface (i.e., antibody-dependent cytotoxicity) and (ii) sensitized T lymphocytes reacting to Tg on the eye muscle cell surface. An antigenic role for EMP is possible, but has not been unequivocally proven. PMID:88053
Do Unilateral Herpetic Stromal Keratitis and Neurotrophic Ulcers Cause Bilateral Dry Eye?
Jabbarvand, Mahmoud; Hashemian, Hesam; Khodaparast, Mehdi; Rafatnejad, Amin; Beheshtnejad, Amirhooshang; Salami, Amir
2015-07-01
To evaluate and compare the ocular surface condition in herpetic interstitial stromal keratitis and neurotrophic ulcer groups and their normal fellow eyes. In this observational, cross-sectional case-control study, 85 consecutive patients were included, including 56 cases of treated herpetic interstitial keratitis and 29 patients with neurotrophic ulcers. Fifty-six age- and sex-matched participants were also recruited from a normal population as the control group. We evaluated and scored the subjective and objective measures of dry eye for both eyes of all patients. Then, we compared the score of the groups with one another and also with the control group. The main outcome measures were the discomfort level, visual symptoms of dry eye, conjunctival injection, conjunctival staining, corneal staining, corneal tear signs of dry eye, meibomian gland dysfunction, tear break-up time, Schirmer test score with anesthesia, and tear osmolarity. The normal fellow eye of the herpetic keratitis group had significantly higher discomfort levels (1.4 ± 0.9 vs. 1.3 ± 0.5, P = 0.003), visual symptoms (1.7 ± 0.8 vs. 1.3 ± 0.7, P = 0.002), tear break-up time (8.3 ± 3.2 vs. 12.1 ± 3.3 seconds, P = 0.003), Schirmer test scores (9.2 ± 3.9 vs. 12.9 ± 3 mm, P = 0.04), and tear osmolarity (9.2 ± 3.9 vs. 12.9 ± 3 mm, P = 0.003) in comparison with normal controls. The normal fellow eyes of the neurotrophic ulcer group had significantly worse values for discomfort level (1.9 ± 0.9 vs. 1.3 ± 0.5, P < 0.001), tear break-up time (7.9 ± 4 vs. 12.1 ± 3.3, P = 0.004), Schirmer test score (8.1 ± 3.9 vs. 12.9 ± 3, P = 0.005), and tear osmolarity (295 ± 9.2 vs. 292.7 ± 5.9, P = 0.02) compared with normal controls. Both eyes of patients with neurotrophic ulcer and interstitial herpetic keratitis have a significantly poorer ocular surface condition compared with that of normal controls.
Kwon, Jin Woo; Chung, Yeon Woong; Choi, Jin A; La, Tae Yoon; Jee, Dong Hyun; Cho, Yang Kyung
2016-01-01
To compare the effects of the surgical insult of cataract surgery on corneal inflammatory infiltration, neovascularization (NV) and lymphangiogenesis (LY) between the dry eye and non-dry eye in murine cataract surgery models. We established two groups of animals, one with normal eyes (non-dry eye) and the second with induced dry eyes. In both groups, we used surgical insults to mimic human cataract surgery, which consisted of lens extraction, corneal incision and suture. After harvesting of corneas on the 9(th) postoperative day and immunohistochemical staining, we compared NV, LY and CD11b+ cell infiltration in the corneas. Dry eye group had significantly more inflammatory infiltration (21.75%±7.17% vs 3.65%±1.49%; P=0.049). The dry eye group showed significantly more NV (48.21%±4.02% vs 26.24%±6.01%; P=0.016) and greater levels of LY (9.27%±0.48% vs 4.84%±1.15%; P=0.007). In corneas on which no surgery was performed, there was no induction of NV in both the dry and non-dry group, but dry eye group demonstrated more CD11b+ cells infiltration than the non-dry eye group (0.360%±0.160% vs 0.023%±0.006%; P=0.068). Dry eye group showed more NV than non-dry eye group in both topical PBS application and subconjunctival PBS injection (P=0.020 and 0.000, respectively). In a murine cataract surgery model, preexisting dry eye can induce more postoperative NV, LY, and inflammation in corneal tissue.
Kwon, Jin Woo; Chung, Yeon Woong; Choi, Jin A; La, Tae Yoon; Jee, Dong Hyun; Cho, Yang Kyung
2016-01-01
AIM To compare the effects of the surgical insult of cataract surgery on corneal inflammatory infiltration, neovascularization (NV) and lymphangiogenesis (LY) between the dry eye and non-dry eye in murine cataract surgery models. METHODS We established two groups of animals, one with normal eyes (non-dry eye) and the second with induced dry eyes. In both groups, we used surgical insults to mimic human cataract surgery, which consisted of lens extraction, corneal incision and suture. After harvesting of corneas on the 9th postoperative day and immunohistochemical staining, we compared NV, LY and CD11b+ cell infiltration in the corneas. RESULTS Dry eye group had significantly more inflammatory infiltration (21.75%±7.17% vs 3.65%±1.49%; P=0.049). The dry eye group showed significantly more NV (48.21%±4.02% vs 26.24%±6.01%; P=0.016) and greater levels of LY (9.27%±0.48% vs 4.84%±1.15%; P=0.007). In corneas on which no surgery was performed, there was no induction of NV in both the dry and non-dry group, but dry eye group demonstrated more CD11b+ cells infiltration than the non-dry eye group (0.360%±0.160% vs 0.023%±0.006%; P=0.068). Dry eye group showed more NV than non-dry eye group in both topical PBS application and subconjunctival PBS injection (P=0.020 and 0.000, respectively). CONCLUSION In a murine cataract surgery model, preexisting dry eye can induce more postoperative NV, LY, and inflammation in corneal tissue. PMID:26949638
Non-Orthogonal Corneal Astigmatism among Normal and Keratoconic Brazilian and Chinese populations.
Abass, Ahmed; Clamp, John; Bao, FangJun; Ambrósio, Renato; Elsheikh, Ahmed
2018-06-01
To investigate the prevalence of non-orthogonal astigmatism among normal and keratoconic Brazilian and Chinese populations. Topography data were obtained using the Pentacam High Resolution (HR) system ® from 458 Brazilian (aged 35.6 ± 15.8 years) and 505 Chinese (aged 31.6 ± 10.8 years) eyes with no history of keratoconus or refractive surgery, and 314 Brazilian (aged 24.2 ± 5.7 years) and 74 Chinese (aged 22.0 ± 5.5 years) keratoconic eyes. Orthogonal values of optical flat and steep powers were determined by finding the angular positions of two perpendicular meridians that gave the maximum difference in power. Additionally, the angular positions of the meridians with the minimum and maximum optical powers were located while being unrestricted by the usual orthogonality assumption. Eyes were determined to have non-orthogonal astigmatism if the angle between the two meridians with maximum and minimum optical power deviated by more than 5° from 90°. Evidence of non-orthogonal astigmatism was found in 39% of the Brazilian keratoconic eyes, 26% of the Chinese keratoconic eyes, 29% of the Brazilian normal eyes and 20% of the Chinese normal eyes. The large percentage of participants with non-orthogonal astigmatism in both normal and keratoconic eyes illustrates the need for the common orthogonality assumption to be reviewed when correcting for astigmatism. The prevalence of non-orthogonality should be considered by expanding the prescription system to consider the two power meridians and their independent positions.
Retinal cell imaging in myopic chickens using adaptive optics multiphoton microscopy.
Bueno, Juan M; Palacios, Raquel; Giakoumaki, Anastasia; Gualda, Emilio J; Schaeffel, Frank; Artal, Pablo
2014-03-01
Abnormal eye growth induced by visual deprivation can modify the structure and density of the retinal cells. We have used an adaptive optics multiphoton microscope to image photoreceptors (PRs) and ganglion cells (GCs) at different retinal locations in unstained retinas of chicken eyes with about 10D of myopia and their normal-sighted fellow eyes. In all samples, the local averaged inter-PR distance increased with eccentricity. No significant differences in PR density were found between control and myopic eyes. GC density declined in myopic eyes compared to control eyes and the inter-cell distance increased. In normal eyes, the size of the GC cell bodies increased approximately two-fold between the area centralis and the peripheral retina. In myopic eyes, this trend was preserved but the GC bodies were larger at each retinal location, compared to control eyes. Obviously, GC morphology is changing when the retinal area is enlarged in myopic eyes.
Retinal cell imaging in myopic chickens using adaptive optics multiphoton microscopy
Bueno, Juan M.; Palacios, Raquel; Giakoumaki, Anastasia; Gualda, Emilio J.; Schaeffel, Frank; Artal, Pablo
2014-01-01
Abnormal eye growth induced by visual deprivation can modify the structure and density of the retinal cells. We have used an adaptive optics multiphoton microscope to image photoreceptors (PRs) and ganglion cells (GCs) at different retinal locations in unstained retinas of chicken eyes with about 10D of myopia and their normal-sighted fellow eyes. In all samples, the local averaged inter-PR distance increased with eccentricity. No significant differences in PR density were found between control and myopic eyes. GC density declined in myopic eyes compared to control eyes and the inter-cell distance increased. In normal eyes, the size of the GC cell bodies increased approximately two-fold between the area centralis and the peripheral retina. In myopic eyes, this trend was preserved but the GC bodies were larger at each retinal location, compared to control eyes. Obviously, GC morphology is changing when the retinal area is enlarged in myopic eyes. PMID:24688804
Neural network application for thermal image recognition of low-resolution objects
NASA Astrophysics Data System (ADS)
Fang, Yi-Chin; Wu, Bo-Wen
2007-02-01
In the ever-changing situation on a battle field, accurate recognition of a distant object is critical to a commander's decision-making and the general public's safety. Efficiently distinguishing between an enemy's armoured vehicles and ordinary civilian houses under all weather conditions has become an important research topic. This study presents a system for recognizing an armoured vehicle by distinguishing marks and contours. The characteristics of 12 different shapes and 12 characters are used to explore thermal image recognition under the circumstance of long distance and low resolution. Although the recognition capability of human eyes is superior to that of artificial intelligence under normal conditions, it tends to deteriorate substantially under long-distance and low-resolution scenarios. This study presents an effective method for choosing features and processing images. The artificial neural network technique is applied to further improve the probability of accurate recognition well beyond the limit of the recognition capability of human eyes.
Don't it make my blue eyes brown: heterochromia and other abnormalities of the iris
Rennie, I G
2012-01-01
Eye colour is one of the most important characteristics in determining facial appearance. In this paper I shall discuss the anatomy and genetics of normal eye colour, together with a wide and diverse range of conditions that may produce an alteration in normal iris pigmentation or form. PMID:21979861
Biobanking of Human Retinas: The Next Big Leap for Eye Banks?
Lužnik, Zala; Parekh, Mohit; Bertolin, Marina; Griffoni, Carlo; Ponzin, Diego
2015-01-01
Summary Retinal degenerative diseases are one of the main clinical causes of incurable and severe visional impairment. Thus, extensive research effort is put into the development of new causal therapeutic options. Promisingly, a number of studies showed regenerative capacity in specific retinal regions (the ciliary epithelium, retinal pigmented epithelium, iris, and Müller glia cells). However, most recent research studies are based on animal models or in vitro cultured cells, probably because of the limited availability of human posterior eye tissues (vitreous, retina, and choroid). To address this, we showed in our previous reports that eye banks with large numbers of globes collected yearly could set up biorepositories/biobanks where these precious tissues are isolated, quality controlled, and finally stored for scientists and clinicians wanting to access human tissues and test their own hypotheses. These precious human posterior eye tissues could be used for further research purposes, epidemiological studies, and target validation of newly developed drugs. In addition, this could be a promising and challenging option to retrieve potential retinal stem and progenitor cells from different parts of the retina and could be a breakthrough in the future delivery of ex vivo prepared customized (histocompatible) retinal tissue on scaffolds for transplantation purposes. In this Perspective, we will consider how the biorepositories could influence the future strategies for retinal stem cell therapies. Significance Retinal degenerative diseases are one of the main causes of severe vision impairment and regenerative medicine is attracting much attention as a potential therapy. Although highly desirable, the reactivation and proliferation of endogenous stem cells in vivo is not sufficient to generate enough cells to restore visual function after retinal injury. Thus, the replacement of exogenously derived normal donor cells is a promising solution. The challenge is to develop therapies with sufficient amounts of cells being harvested or expanded from donor tissues. Eye banks could overcome this issue by harvesting endogenous adult retinal stem cells from different donors. PMID:26032747
Tannenbaum, Dana P; Hoffman, Douglas; Lemij, Hans G; Garway-Heath, David F; Greenfield, David S; Caprioli, Joseph
2004-02-01
The presently available scanning laser polarimeter (SLP) has a fixed corneal compensator (FCC) that neutralizes corneal birefringence only in eyes with birefringence that matches the population mode. A prototype variable corneal compensator (VCC) provides neutralization of individual corneal birefringence based on individual macular retardation patterns. The aim of this study was to evaluate the relative ability of the SLP with the FCC and with the VCC to discriminate between normal and glaucomatous eyes. Prospective, nonrandomized, comparative case series. Algorithm-generating set consisting of 56 normal eyes and 55 glaucomatous eyes and an independent data set consisting of 83 normal eyes and 56 glaucomatous eyes. Sixteen retardation measurements were obtained with the SLP with the FCC and the VCC from all subjects. Dependency of parameters on age, gender, ethnic origin, and eye side was sought. Logistic regression was used to evaluate how well the various parameters could detect glaucoma. Discriminant functions were generated, and the area under the receiver operating characteristic (ROC) curve was determined. Discrimination between normal and glaucomatous eyes on the basis of single parameters was significantly better with the VCC than with the FCC for 6 retardation parameters: nasal average (P = 0.0003), superior maximum (P = 0.0003), ellipse average (P = 0.002), average thickness (P = 0.003), superior average (P = 0.010), and inferior average (P = 0.010). Discriminant analysis identified the optimal combination of parameters for the FCC and for the VCC. When the discriminant functions were applied to the independent data set, areas under the ROC curve were 0.84 for the FCC and 0.90 for the VCC (P<0.021). When the discriminant functions were applied to a subset of patients with early visual field loss, areas under the ROC curve were 0.82 for the FCC and 0.90 for the VCC (P<0.016). Individual correction for corneal birefringence with the VCC significantly improved the ability of the SLP to distinguish between normal and glaucomatous eyes and enabled detection of patients with early glaucoma.
Association of IL-21 cytokine with severity of primary Sjögren syndrome dry eye.
Lim, Sung A; Nam, Doo Hyun; Lee, Jee Hye; Kwok, Seung-Ki; Park, Sung-Hwan; Chung, So-Hyang
2015-03-01
IL-21 plays an important role in primary Sjögren syndrome (SS) pathogenesis. The purpose of this study was to evaluate IL-21 expression in tears and the conjunctiva and to analyze the impact of IL-21 on primary SS dry eyes. Eighty subjects were enrolled in this study: 30 patients with primary SS dry eye (30 eyes); 30 patients with non-SS dry eye (30 eyes), and 20 normal controls. Tear IL-21 levels were measured by flow cytometry, and IL-21 gene expression in the conjunctiva from impression cytology was evaluated by quantitative polymerase chain reaction. Ocular Surface Disease Index, tear film breakup time, Schirmer I test, and ocular surface staining scores were obtained for all patients. Primary SS dry eyes had significantly higher tear IL-21 levels than non-SS dry eyes and normal controls (P < 0.01). In addition, IL-21 gene expression in the conjunctiva was also higher in primary SS dry eyes than in non-SS dry eyes and normal controls (P < 0.01). However, there were no significant differences in IL-21 expression in tears and the conjunctiva between non-SS dry eyes and controls. The tear IL-21 level was significantly correlated with ocular surface stain scores (r = 0.54, P < 0.01) and Schirmer I test values (r = -0.23, P < 0.05) in primary SS dry eyes. Our findings suggest that severity of primary SS dry eye is associated with IL-21.
Dreaming is not controlled by hippocampal mechanisms.
Solms, Mark
2013-12-01
Links with the Humanities are to be welcomed, but they cannot be exempted from normal scientific criteria. Any hypothesis regarding the function of dreams that is premised on rapid eye movement (REM)/dream isomorphism is unsupportable on empirical grounds. Llewellyn's hypothesis has the further problem of counter-evidence in respect of its claim that dreaming relies upon hippocampal functions. The hypothesis also lacks face validity.
Mayama, Chihiro; Tsutsumi, Tae; Saito, Hitomi; Asaoka, Ryo; Tomidokoro, Atsuo; Iwase, Aiko; Otani, Shinichiro; Miyata, Kazunori; Araie, Makoto
2014-01-01
This study was performed to first investigate the morphological differences in the optic nerve head between highly myopic non-glaucomatous controls and highly myopic glaucomatous eyes in comparison with the differences between emmetropic non-glaucomatous controls and emmetropic glaucomatous eyes using confocal scanning laser ophthalmoscopy. Further, the ability of the apparatus in glaucoma diagnosis in highly myopic eyes was compared with that in emmetropic eyes. Healthy subjects and age-matched patients with early-stage open-angle glaucoma were divided into two groups: emmetropic eyes (-1.0 to +1.0 diopters) and highly myopic eyes (-12.0 to -5.0 diopters).The participants were comprised of 65 emmetropic normal eyes, 59 emmetropic glaucomatous eyes, 62 highly myopic normal eyes, and 68 highly myopic glaucomatous eyes and eyes with pathologic myopia were carefully excluded. Confocal scanning laser tomographic parameters were compared among all subjects after adjustment for age and disc area. The ROC curves and sensitivity and specificity for glaucoma detection using several clinical methods were then compared between the emmetropic and highly myopic eyes. Rim area, cup/disc area ratio, mean cup depth, and cup shape measure of glaucoma eyes are significantly different from those of normal eyes in both highly myopic eyes and emmetropic eyes. Methodological overestimation of retinal nerve fiber layer cross sectional area due to optic disc tilting was suggested in the highly myopic eyes. The diagnostic performance of glaucoma using several discriminant methods significantly deteriorated in the highly myopic eyes. In the highly myopic glaucomatous eyes, confocal scanning laser tomographic parameters were significantly different from that of non-glaucomatous highly myopic eyes but diagnostic performance of glaucoma was deteriorated than that in emmetropic eyes. These findings demonstrate the utility and limitations of the apparatus in diagnosing glaucoma in highly myopic patients.
Evidence for object permanence in the smooth-pursuit eye movements of monkeys.
Churchland, Mark M; Chou, I-Han; Lisberger, Stephen G
2003-10-01
We recorded the smooth-pursuit eye movements of monkeys in response to targets that were extinguished (blinked) for 200 ms in mid-trajectory. Eye velocity declined considerably during the target blinks, even when the blinks were completely predictable in time and space. Eye velocity declined whether blinks were presented during steady-state pursuit of a constant-velocity target, during initiation of pursuit before target velocity was reached, or during eye accelerations induced by a change in target velocity. When a physical occluder covered the trajectory of the target during blinks, creating the impression that the target moved behind it, the decline in eye velocity was reduced or abolished. If the target was occluded once the eye had reached target velocity, pursuit was only slightly poorer than normal, uninterrupted pursuit. In contrast, if the target was occluded during the initiation of pursuit, while the eye was accelerating toward target velocity, pursuit during occlusion was very different from normal pursuit. Eye velocity remained relatively stable during target occlusion, showing much less acceleration than normal pursuit and much less of a decline than was produced by a target blink. Anticipatory or predictive eye acceleration was typically observed just prior to the reappearance of the target. Computer simulations show that these results are best understood by assuming that a mechanism of eye-velocity memory remains engaged during target occlusion but is disengaged during target blinks.
Electrical Microstimulation of the Superior Colliculus in Strabismic Monkeys
Fleuriet, Jérome; Walton, Mark M. G.; Ono, Seiji; Mustari, Michael J.
2016-01-01
Purpose Visually guided saccades are disconjugate in human and nonhuman strabismic primates. The superior colliculus (SC) is a region of the brain topographically organized in visual and motor maps where the saccade goal is spatially coded. The present study was designed to investigate if a site of stimulation on the topographic motor map was evoking similar or different saccade vectors for each eye. Methods We used microelectrical stimulation (MS) of the SC in two strabismic (one esotrope and one exotrope) and two control macaques under binocular and monocular viewing conditions. We compared the saccade amplitudes and directions for each SC site and each condition independently of the fixating eye and then between each fixating eye. A comparison with disconjugacies of visually guided saccades was also performed. Results We observed different saccade vectors for the two eyes in strabismic monkeys, but conjugate saccades in normal monkeys. Evoked saccade vectors for the left eye when that eye was fixating the target were different from those of the right eye when it was fixating. The disconjugacies evoked by the MS were not identical but similar to those observed for visually guided saccades especially for the dominant eye. Conclusions Our results suggest that, in strabismus, the saccade generator does not interpret activation of a single location of the SC as the same desired displacement for each eye. This finding is important for advancing understanding of the development of neural circuits in strabismus. French Abstract PMID:27309621
Gosling, Allyson A; Kiland, Julie A; Rutkowski, Lauren E; Hoefs, Adam; Ellinwood, N Matthew; McLellan, Gillian J
2016-01-01
Objective to determine the effect of topical corticosteroid (CCS) therapy on intraocular pressure (IOP) in normal cats and cats with primary feline congenital glaucoma (FCG). Animals studied 5 normal and 11 FCG cats were studied in 2 cohorts. Procedures IOP was measured by a single, masked observer, once daily 3–5 days/week throughout the course of CCS treatment and for up to 11 days after treatment discontinuation. One eye per cat was randomly assigned for treatment twice daily with CCS; Balanced salt solution (BSS) applied to the contralateral eye, served as a control. Differences between eyes and between weeks of the study period were calculated for each cat. A positive response to CCS was defined as a consistent >15% or >25% higher IOP in the treated relative to control eye in normal and FCG cats, respectively. Results 8/11 FCG cats responded to topical CCS after 1–5 weeks of treatment with an increase in IOP relative to the untreated eye (maximum IOP discrepancy of 56 mmHg). 2/5 normal cats responded to topical CCS with appreciable but clinically unimportant increase in IOP in the treated eye (maximum IOP discrepancy of 6.4 mmHg). Conclusions our data indicate that the incidence of steroid induced IOP elevation in cats is lower than previously published feline studies suggest. Cats with pre-existing compromise in aqueous humor outflow may show a greater, clinically relevant response to topical CCS than normal cats. PMID:26876736
Implicit prosody mining based on the human eye image capture technology
NASA Astrophysics Data System (ADS)
Gao, Pei-pei; Liu, Feng
2013-08-01
The technology of eye tracker has become the main methods of analyzing the recognition issues in human-computer interaction. Human eye image capture is the key problem of the eye tracking. Based on further research, a new human-computer interaction method introduced to enrich the form of speech synthetic. We propose a method of Implicit Prosody mining based on the human eye image capture technology to extract the parameters from the image of human eyes when reading, control and drive prosody generation in speech synthesis, and establish prosodic model with high simulation accuracy. Duration model is key issues for prosody generation. For the duration model, this paper put forward a new idea for obtaining gaze duration of eyes when reading based on the eye image capture technology, and synchronous controlling this duration and pronunciation duration in speech synthesis. The movement of human eyes during reading is a comprehensive multi-factor interactive process, such as gaze, twitching and backsight. Therefore, how to extract the appropriate information from the image of human eyes need to be considered and the gaze regularity of eyes need to be obtained as references of modeling. Based on the analysis of current three kinds of eye movement control model and the characteristics of the Implicit Prosody reading, relative independence between speech processing system of text and eye movement control system was discussed. It was proved that under the same text familiarity condition, gaze duration of eyes when reading and internal voice pronunciation duration are synchronous. The eye gaze duration model based on the Chinese language level prosodic structure was presented to change previous methods of machine learning and probability forecasting, obtain readers' real internal reading rhythm and to synthesize voice with personalized rhythm. This research will enrich human-computer interactive form, and will be practical significance and application prospect in terms of disabled assisted speech interaction. Experiments show that Implicit Prosody mining based on the human eye image capture technology makes the synthesized speech has more flexible expressions.
Saccadic eye movements analysis as a measure of drug effect on central nervous system function.
Tedeschi, G; Quattrone, A; Bonavita, V
1986-04-01
Peak velocity (PSV) and duration (SD) of horizontal saccadic eye movements are demonstrably under the control of specific brain stem structures. Experimental and clinical evidence suggest the existence of an immediate premotor system for saccade generation located in the paramedian pontine reticular formation (PPRF). Effects on saccadic eye movements have been studied in normal volunteers with barbiturates, benzodiazepines, amphetamine and ethanol. On two occasions computer analysis of PSV, SD, saccade reaction time (SRT) and saccade accuracy (SA) was carried out in comparison with more traditional methods of assessment of human psychomotor performance like choice reaction time (CRT) and critical flicker fusion threshold (CFFT). The computer system proved to be a highly sensitive and objective method for measuring drug effect on central nervous system (CNS) function. It allows almost continuous sampling of data and appears to be particularly suitable for studying rapidly changing drug effects on the CNS.
Li, Yan; Chamberlain, Winston; Tan, Ou; Brass, Robert; Weiss, Jack L.; Huang, David
2016-01-01
PURPOSE To screen for subclinical keratoconus by analyzing corneal, epithelial, and stromal thickness map patterns with Fourier-domain optical coherence tomography (OCT). SETTING Four centers in the United States. DESIGN Cross-sectional observational study. METHODS Eyes of normal subjects, subclinical keratoconus eyes, and the topographically normal eye of a unilateral keratoconus patient were studied. Corneas were scanned using a 26 000 Hz Fourier-domain OCT system (RTVue). Normal subjects were divided into training and evaluation groups. Corneal, epithelial, and stromal thickness maps and derived diagnostic indices, including pattern standard deviation (PSD) variables and pachymetric map–based keratoconus risk scores were calculated from the OCT data. Area under the receiver operating characteristic curve (AUC) analysis was used to evaluate the diagnostic accuracy of the indices. RESULTS The study comprised 150 eyes of 83 normal subjects, 50 subclinical keratoconus eyes of 32 patients, and 1 topographically normal eye of a unilateral keratoconus patient. Subclinical keratoconus was characterized by inferotemporal thinning of the cornea, epithelium, and stroma. The PSD values for corneal (P < .001), epithelial (P < .001), and stromal (P = .049) thickness maps were all significantly higher in subclinical keratoconic eyes than in the normal group. The diagnostic accuracy was significantly higher for PSD variables (pachymetric PSD, AUC = 0.941; epithelial PSD, AUC = 0.985; stromal PSD, AUC = 0.924) than for the pachymetric map–based keratoconus risk score (AUC = 0.735). CONCLUSIONS High-resolution Fourier-domain OCT could map corneal, epithelial, and stromal thicknesses. Corneal and sublayer thickness changes in subclinical keratoconus could be detected with high accuracy using PSD variables. These new diagnostic variables might be useful in the detection of early keratoconus. PMID:27026454
Corneal thickness in dry eyes in an Iraqi population.
Ali, Noora Mauwafak; Hamied, Furkaan M; Farhood, Qasim K
2017-01-01
Dry eye disorder is a multifactorial disease of the tears and ocular surface that results in discomfort and visual disturbance. Corneal pachymetry becomes increasingly important in refractive surgery, for the accurate assessment of intraocular pressure, and in the preoperative assessment of other ocular surgeries. To assess the effect of dry eye disorder on the central corneal thickness (CCT) by comparing with CCT of normal eyes of age-matched individuals. The total number of eyes examined was 280 (140 dry eyes from 70 patients and 140 normal eyes from 70 individuals). Pentacam (Scheimpflug imaging system) was used for measuring the CCT of all eyes. Patients with dry eye syndrome had significantly lower CCT compared to the control group ( P <0.01). Its mean was 536.5 versus 561.3, respectively. CCT of dry eyes was significantly reduced when compared with age- and gender-matched population. This result can be attributed to chronic desiccation by the inflammatory mediators in dry eyes, leading to corneal thinning.
Shi, Jingming; Jiag, Youqin; Liu, Xuyang
2004-07-01
To investigate if Erigeron Breviscapus (vant) Hand-Mazz (EBHM) has a neuroprotective effect against NMDA-induced neuron death in retinal ganglion cell layer (RGCL). Sixty healthy SD rats were randomly divided into four groups. 6 animals were in normal control group (group A). The others were divided as group B (EBHM group), group C (normal saline+NMDA group), group D (EBHM+NMDA group). Each group has 18 rats. 10 nmol NMDA was chosen for intravitreal injection to cause partial damage of the neurons in RGCL in the right eyes of Groups C and D. Same volume PBS was intravitreal injected in the left eyes as self-control. Groups B and D were pre-treated intraperitoneally with 6% EBHM solution at a dose of 15 mg x 100 g(-1) x d(-1) seven days before and after NMDA treatment. Group C were administrated intraperitoneally with 0.9% normal saline at the same time of EBHM injection. Rats were sacrificed in 4, 7, 14 days after NMDA treatment. Flat preparation of whole retinas were stained with 0.5% cresyl violet and neuron counting in RGCL from both eyes. Each subgroup has 6 rats. There was no significant difference between the right eye and the left eye of neuron counting from RGCL in normal control group (group A) (P=0.200). There was no significant difference between normal control group and EBHM group either in the right eyes or in the left eye in 4 days, 7 days and 14 days respectively after intravitreal injection of 10 nmol NMDA in group C and group D. (P=0.636, P=0.193). Neuron counting from RGCL of group C and group D were significant decreased in the NMDA-treated eyes in 4 days, 7 days and 14 days after intravitreal injection (P < 0.001). There ws no significant difference between self-control eyes and normal control group (P > 0.05). Neuron counting was significantly higher in the EBHM+NMDA group than normal saline+NMDA group at 14 days after intraviteal injection (P=0.044). However,it is obvious that the difference was still significant between normal control group and EBHM+NMDA group (P < 0.05). EBHM has no effect on neuron counting of RGCL when administered alone in normal rats. It is suggested that EBHM has partial protective effect on NMDA-induced neuron loss in RGCL in the rat.
Ogura, Atsushi; Ikeo, Kazuho; Gojobori, Takashi
2004-01-01
Although the camera eye of the octopus is very similar to that of humans, phylogenetic and embryological analyses have suggested that their camera eyes have been acquired independently. It has been known as a typical example of convergent evolution. To study the molecular basis of convergent evolution of camera eyes, we conducted a comparative analysis of gene expression in octopus and human camera eyes. We sequenced 16,432 ESTs of the octopus eye, leading to 1052 nonredundant genes that have matches in the protein database. Comparing these 1052 genes with 13,303 already-known ESTs of the human eye, 729 (69.3%) genes were commonly expressed between the human and octopus eyes. On the contrary, when we compared octopus eye ESTs with human connective tissue ESTs, the expression similarity was quite low. To trace the evolutionary changes that are potentially responsible for camera eye formation, we also compared octopus-eye ESTs with the completed genome sequences of other organisms. We found that 1019 out of the 1052 genes had already existed at the common ancestor of bilateria, and 875 genes were conserved between humans and octopuses. It suggests that a larger number of conserved genes and their similar gene expression may be responsible for the convergent evolution of the camera eye. PMID:15289475
Collins, Melanie M; Johnson, Ian J M; Clifford, Elaine; Birchall, John P; O'Donoghue, Gerald M
2003-04-01
The objective was to evaluate the preoperative postural stability of acoustic neuroma patients using sway magnetometry. Prospective two-center study. Fifty-one patients (mean age, 53 years) diagnosed with unilateral acoustic neuroma on magnetic resonance imaging at two tertiary referral centers were studied. Preoperatively, each patient had sway patterns (with eyes open and with eyes closed, and standing on foam) recorded for 120 seconds by sway magnetometry. Path length for 30 seconds was calculated. The Romberg coefficient (path length with eyes open divided by path length with eyes closed) was calculated. Forty-four percent of patients had abnormal path lengths with eyes open, and 49% with eyes closed. The Romberg coefficients were significantly lower than normal (P <.001; 95% CI, 0.19-0.87). Mean Romberg coefficient was 0.59 (normal value = 0.73), and all patients had a coefficient of less than 1. Half of preoperative acoustic neuroma patients are unsteady, exhibiting abnormal sway patterns based on path length measurements. The increase in sway path length demonstrable in normal subjects with eyes closed was significantly exaggerated in patients with acoustic neuroma.
Spatola, Ronald; Nadelstein, Brad; Berdoulay, Andrew; English, Robert V
2018-05-01
To evaluate the effect of twice daily aqueous 0.02% sirolimus drops on tear production in normal dogs and dogs with refractory keratoconjunctivitis sicca (KCS). Two groups of dogs were studied. Ten normal dogs with no signs of ocular disease were administered topical 0.02% sirolimus ophthalmic solution in right eye, and a vehicle control in the left eye twice daily for 4 weeks. Complete ophthalmic examinations, including Schirmer tear test were performed weekly. Eighteen dogs with refractory KCS were randomly assigned to receive 0.02% sirolumus ophthalmic solution or 0.02% tacrolimus ophthalmic solution twice daily. Complete ophthalmic examinations were was performed at 2 and 6 weeks following treatment. Tear production in the sirolimus-treated eyes of normal dogs was greater when compared to vehicle controls with a mean difference over all time points of 3.46 mm (95% CI 1.17, 5.75; P = 0.006). After 4 weeks of treatment, the mean difference was 5 mm (95% CI 1.95, 8.05; P = 0.002). In dogs with refractory dry eye, 37.5% of eyes treated with sirolimus exhibited increased tear production >4 mm/min after 6 weeks of treatment, compared to 20% of eyes receiving tacrolimus (P = 0.433). One normal dog experienced topical irritation to both sirolimus and vehicle-treatment. Side effects were not reported in any treated eyes with chronic KCS. Topical 0.02% sirolimus might be an alternative treatment for canine patients with keratoconjunctivits sicca. The drug appears safe when applied topically in an aqueous suspension for up to 6 weeks. While initial results are promising, further studies are warranted. © 2017 American College of Veterinary Ophthalmologists.
Zhou, Hai Yan; Yan, Hong; Wang, Li Li; Yan, Wei Jia; Shui, Ying Bo; Beebe, David C
2015-08-01
The goal of this study was to quantitatively identify the differentially expressed proteins in nuclear cataracts of different ages and normal lens nuclei in humans. Forty-eight human lens nucleus samples with hardness grades III, IV were obtained during cataract surgery by extracapsular cataract extraction. Seven normal transparent human lens nuclei were obtained from fresh normal cadaver eyes during corneal transplantation surgery. Lens nuclei were divided into seven groups according to age and optic axis: Group A (average age 80.8 ± 1.2 years), Group B (average age 57.0 ± 4.0 years), Group C average age 80.3 ± 4.5 years), Group D (average age 56.9 ± 4.2 years), Group E (average age 78.1 ± 2.5 years), Group F (average age 57.6 ± 3.3 years) and Group G (seven normal transparent human lenses from normal cadaver eyes, average age 34.7 ± 4.2 years). Water-soluble, water-insoluble, and water-insoluble-urea-soluble protein fractions were extracted from samples. The three-part protein fractions from the individual lenses were combined to form the total proteins of each sample. The proteomic profiles of each group were further analyzed using 8-plex iTRAQ labeling combined with 2D-LC-MS/MS. The data were analyzed with the ProteinPilot software for peptide matching, protein identification, and quantification. Differentially expressed proteins were validated by Western blotting. We employed biological and technical replicates and selected the intersection of the two results, which included 80 proteins. Nine proteins were differentially expressed among the 80 proteins identified using proteomic techniques. In age-related nuclear cataracts (ARNC), the expression levels of fatty acid-binding protein and pterin-4-alpha-carbinolamine dehydratase were upregulated, whereas the levels of alpha-crystallin B chain (CRYAB), GSH synthetase, phakinin, gamma-crystallin C, phosphoglycerate kinase 1, betaine-homocysteine S-methyltransferase 1 (BHMT1), and spectrin beta chain were downregulated. These proteins may be associated with abnormal protein aggregation and oxidative stress. GSH synthetase and CRYAB expression levels in the nuclear cataract decreased with age. The mass spectrometric analysis results were consistent with the Western blot validation. The results indicate that CRYAB and GSH synthetase may be involved in ARNC pathogenesis. iTRAQ combined with 2D-LC-MS/MS provides new methods for future studies of pathological mechanisms and protective drug development for ARNC. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Zhang, Lijun; Danesh, Jennifer; Tannan, Anjali; Phan, Vivian; Yu, Fei; Hamilton, D Rex
2015-10-01
To evaluate the difference in corneal biomechanical waveform parameters between manifest keratoconus, forme fruste keratoconus, and healthy eyes with a second-generation biomechanical waveform analyzer (Ocular Response Analyzer 2). Jules Stein Eye Institute, University of California, Los Angeles, California, USA. Retrospective chart review. The biomechanical waveform analyzer was used to obtain corneal hysteresis (CH), corneal resistance factor (CRF), and 37 biomechanical waveform parameters in manifest keratoconus eyes, forme fruste keratoconus eyes, and healthy eyes. Useful distinguishing parameters were found using t tests and a multivariable logistic regression model with stepwise variable selection. Potential confounders were controlled for. The study included 68 manifest keratoconus eyes, 64 forme fruste keratoconus eyes, and 249 healthy eyes. There was a statistical difference in the mean CRF between the normal group (10.2 mm Hg ± 1.7 [SD]) and keratoconus group (6.3 ± 1.9 mm Hg) (P = .003), and between the normal group and the forme fruste keratoconus group (7.8 ± 1.4 mm Hg) (P < .0001). There was no statistical difference in the mean CH between the normal group and the keratoconus group or the forme fruste keratoconus group. The CRF, height of peak 1 (P1) (P = .001), downslope of P1 (dslope1) (P = .027), upslope of peak 2 (P2) (P = .004), and downslope of P2 (P = .006) distinguished the normal group from the keratoconus groups. The CRF, downslope of P2 derived from upper 50% of applanation peak (P = .035), dslope1 (P = .014), and upslope of P1 (P = .008) distinguished the normal group from the forme fruste keratoconus group. Differences in multiple biomechanical waveform parameters can differentiate between healthy and diseased conditions and might improve early diagnosis of keratoconus and forme fruste keratoconus. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Assessing the True Intraocular Pressure in the Non-human Primate.
McAllister, Faith; Harwerth, Ronald; Patel, Nimesh
2018-02-01
For glaucoma patients, high intraocular pressure (IOP) is a risk factor for progressive neuropathy. Similarly, animal models used to study the disease are based on an experimental elevation of IOP. Thus, accurate IOP measurements are important in characterizing experimental models and resulting effects. The purpose of the present study was to investigate IOP measurements in a non-human primate model of experimental glaucoma by comparing clinical tonometry (Tono-Pen and TonoVet) to the true IOP from intracameral manometry. A total of 17 rhesus macaque eyes from 12 animals were used for this study. Eleven eyes had no previous experimental intervention, whereas six eyes were at varying stages of laser-induced experimental glaucoma. IOPs were adjusted by inserting a needle in the anterior chamber that was attached to a pressure transducer and syringe pump system. The anterior chamber IOP was adjusted to values between 10 and 50 mmHg and corresponding measures with Tono-Pen and TonoVet were taken. The IOPs by TonoVet and Tono-Pen were linearly related over the range of pressures tested (slope = 0.68 normal/healthy and 0.72 experimental glaucoma). For the most, TonoVet measures overestimated IOP at all anterior chamber pressure settings (mean difference of 3.17 mmHg, 95% CI 12.53 to -4.74 normal and 3.90 mmHg, 95% CI 12.90 to -6.53 experimental glaucoma). In contrast, Tono-Pen measures overestimated IOP at lower IOPs and underestimated at higher IOP (slope = -0.26 normal and -0.21 experimental glaucoma). The TonoVet and Tono-Pen tonometers that are often used to assess IOP in both clinical and experimental settings generally reflect the status of IOP, but the results from this study suggest that the instruments need calibration with true anterior chamber pressure for accurate measures in experimental models of glaucoma.
Zou, Leilei; Liu, Rui; Zhang, Xiaohui; Chu, Renyuan; Dai, Jinhui; Zhou, Hao
2014-01-01
Purpose Scleral remodeling is an important mechanism underlying the development of myopia. Atropine, an antagonist of G protein-coupled muscarinic receptors, is currently used as an off-label treatment for myopia. Regulator of G-protein signaling 2 (RGS2) functions as an intracellular selective inhibitor of muscarinic receptors. In this study we measured scleral RGS2 expression and scleral remodeling in an animal model of myopia in the presence or absence of atropine treatment. Methods Guinea pigs were assigned to four groups: normal (free of form deprivation), form deprivation myopia (FDM) for 4 weeks, FDM treated with saline, and FDM treated with atropine. Biometric measurements were then performed. RGS2 expression levels and scleral remodeling, including scleral thickness and collagen type I expression, were compared among the four groups. Results Compared with normal eyes and contralateral control eyes, the FDM eyes had the most prominent changes in refraction, axial length, and scleral remodeling, indicating myopia. There was no significant difference between control and normal eyes. Hematoxylin and eosin staining showed that the scleral thickness was significantly thinner in the posterior pole region of FDM eyes compared to normal eyes. Real-time PCR and western blot analysis showed a significant decrease in posterior scleral collagen type I mRNA and protein expression in the FDM eyes compared to the normal eyes. The FDM eyes also had increased levels of RGS2 mRNA and protein expression in the sclera. Atropine treatment attenuated the FDM-induced changes in refraction, axial length, and scleral remodeling. Interestingly, atropine treatment significantly increased collagen type I mRNA expression but decreased RGS2 mRNA and protein expression in the sclera of the FDM eyes. Conclusions We identified a significant RGS2 upregulation and collagen type I downregulation in the sclera of FDM eyes, which could be partially attenuated by atropine treatment. Our data suggest that targeting dysregulated RGS2 may provide a novel strategy for development of therapeutic agents to suppress myopia progression. PMID:25018620
A novel nanoscale-dispersed eye ointment for the treatment of dry eye disease
NASA Astrophysics Data System (ADS)
Zhang, Wenjian; Wang, Yan; Lee, Benjamin Tak Kwong; Liu, Chang; Wei, Gang; Lu, Weiyue
2014-03-01
A novel nanoscale-dispersed eye ointment (NDEO) for the treatment of severe evaporative dry eye has been successfully developed. The excipients used as semisolid lipids were petrolatum and lanolin, as used in conventional eye ointment, which were coupled with medium-chain triglycerides (MCT) as a liquid lipid; both phases were then dispersed in polyvinyl pyrrolidone solution to form a nanodispersion. Single-factor experiments were conducted to optimize the formulations. A transmission electron micrograph showed that the ointment matrix was entrapped in the nanoemulsion of MCT, with a mean particle size of about 100 nm. The optimized formulation of NDEO was stable when stored for six months at 4 °C, and demonstrated no cytotoxicity to human corneal epithelial cells when compared with commercial polymer-based artificial tears (Tears Natural® Forte). The therapeutic effects of NDEO were evaluated on a mouse model with ‘dry eye’. Both the tear break-up time and fluorescein staining demonstrated therapeutic improvement, displaying a trend of positive correlation with higher concentrations of ointment matrix in the NDEO formulations compared to a marketed product. Histological evaluation demonstrated that the NDEO restored the normal corneal and conjunctival morphology and is safe for ophthalmic application.
Assessment of corneal epithelial thickness in dry eye patients.
Cui, Xinhan; Hong, Jiaxu; Wang, Fei; Deng, Sophie X; Yang, Yujing; Zhu, Xiaoyu; Wu, Dan; Zhao, Yujin; Xu, Jianjiang
2014-12-01
To investigate the features of corneal epithelial thickness topography with Fourier-domain optical coherence tomography (OCT) in dry eye patients. In this cross-sectional study, 100 symptomatic dry eye patients and 35 normal subjects were enrolled. All participants answered the ocular surface disease index questionnaire and were subjected to OCT, corneal fluorescein staining, tear breakup time, Schirmer 1 test without anesthetic (S1t), and meibomian morphology. Several epithelium statistics for each eye, including central, superior, inferior, minimum, maximum, minimum - maximum, and map standard deviation, were averaged. Correlations of epithelial thickness with the symptoms of dry eye were calculated. The mean (±SD) central, superior, and inferior corneal epithelial thickness was 53.57 (±3.31) μm, 52.00 (±3.39) μm, and 53.03 (±3.67) μm in normal eyes and 52.71 (±2.83) μm, 50.58 (±3.44) μm, and 52.53 (±3.36) μm in dry eyes, respectively. The superior corneal epithelium was thinner in dry eye patients compared with normal subjects (p = 0.037), whereas central and inferior epithelium were not statistically different. In the dry eye group, patients with higher severity grades had thinner superior (p = 0.017) and minimum (p < 0.001) epithelial thickness, more wide range (p = 0.032), and greater deviation (p = 0.003). The average central epithelial thickness had no correlation with tear breakup time, S1t, or the severity of meibomian glands, whereas average superior epithelial thickness positively correlated with S1t (r = 0.238, p = 0.017). Fourier-domain OCT demonstrated that the thickness map of the dry eye corneal epithelium was thinner than normal eyes in the superior region. In more severe dry eye disease patients, the superior and minimum epithelium was much thinner, with a greater range of map standard deviation.
Temporal Dynamics of Ocular Position Dependence of the Initial Human Vestibulo-ocular Reflex
Crane, Benjamin T.; Tian, Junru; Demer, Joseph L.
2007-01-01
Purpose While an ideal vestibulo-ocular reflex (VOR) generates ocular rotations compensatory for head motion, during visually guided movements, Listing’s Law (LL) constrains the eye to rotational axes lying in Listing’s Plane (LP). The present study was conducted to explore the recent proposal that the VOR’s rotational axis is not collinear with the head’s, but rather follows a time-dependent strategy intermediate between LL and an ideal VOR. Methods Binocular LPs were defined during visual fixation in eight normal humans. The VOR was evoked by a highly repeatable transient whole-body yaw rotation in darkness at a peak acceleration of 2800 deg/s2. Immediately before rotation, subjects regarded targets 15 or 500 cm distant located at eye level, 20° up, or 20° down. Eye and head responses were compared with LL predictions in the position and velocity domains. Results LP orientation varied both among subjects and between individual subject’s eyes, and rotated temporally with convergence by 5 ± 5° (±SEM). In the position domain, the eye compensated for head displacement even when the head rotated out of LP. Even within the first 20 ms from onset of head rotation, the ocular velocity axis tilted relative to the head axis by 30% ± 8% of vertical gaze position. Saccades increased this tilt. Regardless of vertical gaze position, the ocular rotation axis tilted backward 4° farther in abduction than in adduction. There was also a binocular vertical eye velocity transient and lateral tilt of the ocular axis. Conclusions These disconjugate, short-latency axis perturbations appear intrinsic to the VOR and may have neural or mechanical origins. PMID:16565376
Application of a new high-speed magnetic deformable mirror for in-vivo retinal imaging
NASA Astrophysics Data System (ADS)
Balderas-Mata, Sandra E.; Jones, Steven M.; Zawadzki, Robert J.; Werner, John S.
2011-08-01
Nowadays in ophthalmologic practice several commercial instruments are available to image patient retinas in vivo. Many modern fundus cameras and confocal scanning laser ophthalmoscopes allow acquisition of two dimensional en face images of the retina with both back reflected as well as fluorescent light. Additionally, optical coherence tomography systems allow non-invasive probing of three-dimensional retinal morphology. For all of these instruments the available lateral resolution is limited by optical quality of the human eye used as the imaging objective. To improve lateral resolution and achieve diffraction-limited imaging, adaptive optics (AO) can be implemented with any of these imaging systems to correct both static and dynamic aberrations inherent in human eyes. Most of the wavefront correctors used previously in AO systems have limited dynamic range and an insufficient number of actuators to achieve diffraction-limited correction of most human eyes. Thus, additional corrections were necessary, either by trial lenses or additional deformable mirrors (DMs). The UC Davis AO flood-illuminated fundus camera system described in this paper has been previously used to acquire in vivo images of the photoreceptor mosaic and for psychophysical studies on normal and diseased retinas. These results were acquired using a DM manufactured by Litton ITEK (DM109), which has 109 actuators arranged in a hexagonal array below a continuous front-surface mirror. It has an approximate surface actuator stroke of +/-2μm. Here we present results with a new hi-speed magnetic DM manufactured by ALPAO (DM97, voice coil technology), which has 97 actuators and similar inter-actuator stroke (>3μm, mirror surface) but much higher low-order aberration correction (defocus stroke of at least +/-30μm) than the previous one. In this paper we report results of testing performance of the ALPAO DM for the correction of human eye aberrations. Additionally changes made to our AO flood illuminated system are presented along with images of the model eye retina and in-vivo human retina acquired with this system.
Ability of Cirrus™ HD-OCT Optic Nerve Head Parameters to Discriminate Normal from Glaucomatous Eyes
Mwanza, Jean-Claude; Oakley, Jonathan D; Budenz, Donald L; Anderson, Douglas R
2010-01-01
Purpose To determine the ability of optic nerve head (ONH) parameters measured with spectral domain Cirrus™ HD-OCT to discriminate between normal and glaucomatous eyes and to compare them to the discriminating ability of peripapillary retinal nerve fiber layer (RNFL) thickness measurements performed with Cirrus™ HD-OCT. Design Evaluation of diagnostic test or technology. Participants Seventy-three subjects with glaucoma and one hundred and forty-six age-matched normal subjects. Methods Peripapillary ONH parameters and RNFL thickness were measured in one randomly selected eye of each participant within a 200×200 pixel A-scan acquired with Cirrus™ HD-OCT centered on the ONH. Main Outcome Measures ONH topographic parameters, peripapillary RNFL thickness, and the area under receiver operating characteristic curves (AUCs). Results For distinguishing normal from glaucomatous eyes, regardless of disease stage, the six best parameters (expressed as AUC) were vertical rim thickness (VRT, 0.963), rim area (RA, 0.962), RNFL thickness at clock-hour 7 (0.957), RNFL thickness of the inferior quadrant (0.953), vertical cup-to-disc ratio (VCDR, 0.951) and average RNFL thickness (0.950). The AUC for distinguishing between normal and eyes with mild glaucoma was greatest for RNFL thickness of clock-hour 7 (0.918), VRT (0.914), RA (0.912), RNFL thickness of inferior quadrant (0.895), average RNFL thickness (0.893) and VCDR (0.890). There were no statistically significant differences between AUCs for the best ONH parameters and RNFL thickness measurements (p > 0.05). Conclusions Cirrus™ HD-OCT ONH parameters are able to discriminate between eyes that are normal from those with glaucoma or even mild glaucoma. There is no difference in the ability of ONH parameters and RNFL thickness measurement, as measured with Cirrus™ OCT, to distinguish between normal and glaucomatous eyes. PMID:20920824
Weber, Arthur J; Viswanáthan, Suresh; Ramanathan, Chidambaram; Harman, Christine D
2010-01-01
To determine whether application of BDNF to the eye and brain provides a greater level of neuroprotection after optic nerve injury than treatment of the eye alone. Retinal ganglion cell survival and pattern electroretinographic responses were compared in normal cat eyes and in eyes that received (1) a mild nerve crush and no treatment, (2) a single intravitreal injection of BDNF at the time of the nerve injury, or (3) intravitreal treatment combined with 1 to 2 weeks of continuous delivery of BDNF to the visual cortex, bilaterally. Relative to no treatment, administration of BDNF to the eye alone resulted in a significant increase in ganglion cell survival at both 1 and 2 weeks after nerve crush (1 week, 79% vs. 55%; 2 weeks, 60% vs. 31%). Combined treatment of the eye and visual cortex resulted in a modest additional increase (17%) in ganglion cell survival in the 1-week eyes, a further significant increase (55%) in the 2-week eyes, and ganglion cell survival levels for both that were comparable to normal (92%-93% survival). Pattern ERG responses for all the treated eyes were comparable to normal at 1 week after injury; however, at 2 weeks, only the responses of eyes receiving the combined BDNF treatment remained so. Although treatment of the eye alone with BDNF has a significant impact on ganglion cell survival after optic nerve injury, combined treatment of the eye and brain may represent an even more effective approach and should be considered in the development of future optic neuropathy-related neuroprotection strategies.
Ashtari, Manzar; Zhang, Hui; Cook, Philip A; Cyckowski, Laura L; Shindler, Kenneth S; Marshall, Kathleen A; Aravand, Puya; Vossough, Arastoo; Gee, James C; Maguire, Albert M; Baker, Chris I; Bennett, Jean
2015-07-15
Much of our knowledge of the mechanisms underlying plasticity in the visual cortex in response to visual impairment, vision restoration, and environmental interactions comes from animal studies. We evaluated human brain plasticity in a group of patients with Leber's congenital amaurosis (LCA), who regained vision through gene therapy. Using non-invasive multimodal neuroimaging methods, we demonstrated that reversing blindness with gene therapy promoted long-term structural plasticity in the visual pathways emanating from the treated retina of LCA patients. The data revealed improvements and normalization along the visual fibers corresponding to the site of retinal injection of the gene therapy vector carrying the therapeutic gene in the treated eye compared to the visual pathway for the untreated eye of LCA patients. After gene therapy, the primary visual pathways (for example, geniculostriate fibers) in the treated retina were similar to those of sighted control subjects, whereas the primary visual pathways of the untreated retina continued to deteriorate. Our results suggest that visual experience, enhanced by gene therapy, may be responsible for the reorganization and maturation of synaptic connectivity in the visual pathways of the treated eye in LCA patients. The interactions between the eye and the brain enabled improved and sustained long-term visual function in patients with LCA after gene therapy. Copyright © 2015, American Association for the Advancement of Science.
Roberts, Michael D.; Grau, Vicente; Grimm, Jonathan; Reynaud, Juan; Bellezza, Anthony J.; Burgoyne, Claude F.; Downs, J. Crawford
2009-01-01
Purpose To characterize the trabeculated connective tissue microarchitecture of the lamina cribrosa (LC) in terms of total connective tissue volume (CTV), connective tissue volume fraction (CTVF), predominant beam orientation, and material anisotropy in monkeys with early experimental glaucoma (EG). Methods The optic nerve heads from three monkeys with unilateral EG and four bilaterally normal monkeys were three dimensionally reconstructed from tissues perfusion fixed at an intraocular pressure of 10 mm Hg. A three-dimensional segmentation algorithm was used to extract a binary, voxel-based representation of the porous LC connective tissue microstructure that was regionalized into 45 subvolumes, and the following quantities were calculated: total CTV within the LC, mean and regional CTVF, regional predominant beam orientation, and mean and regional material anisotropy. Results Regional variation within the laminar microstructure was considerable within the normal eyes of all monkeys. The laminar connective tissue was generally most dense in the central and superior regions for the paired normal eyes, and laminar beams were radially oriented at the periphery for all eyes considered. CTV increased substantially in EG eyes compared with contralateral normal eyes (82%, 44%, 45% increases; P < 0.05), but average CTVF changed little (−7%, 1%, and −2% in the EG eyes). There were more laminar beams through the thickness of the LC in the EG eyes than in the normal controls (46%, 18%, 17% increases). Conclusions The substantial increase in laminar CTV with little change in CTVF suggests that significant alterations in connective and nonconnective tissue components in the laminar region occur in the early stages of glaucomatous damage. PMID:18806292
Chan, Tommy C Y; Ye, Cong; Chan, Kwok Ping; Chu, Kai On; Jhanji, Vishal
2016-09-01
To evaluate the performance of a point-of-care test for detection of matrix metalloproteinase 9 (MMP-9) levels in post-laser-assisted in situ keratomileusis (LASIK) dry eyes. A comparative study between patients with mild to moderate post-LASIK dry eyes and age-matched normal subjects was conducted. Ocular surface disease index (OSDI), tear break-up time (TBUT), and tear film MMP-9 and total protein levels were compared between the two groups. A point-of-care test device (RPS InflammaDry, Sarasota, Florida, USA) was utilised to confirm elevated MMP-9 levels in tear film. Fourteen post-LASIK dry eyes and 34 normal eyes were included. There was no significant difference in age and gender between both groups (p>0.175). The OSDI was significantly higher (25.5±7.7 vs 7.4±2.5; p<0.001) and TBUT levels were significantly lower (5.4±0.9 vs 13.5±2.3; p<0.001) in patients with dry eye compared with normal subjects. The tear film MMP-9 levels were 52.7±32.5 ng/mL in dry eyes and 4.1±2.1 ng/mL in normal eyes (p<0.001). MMP-9 levels were >40 ng/mL in 7/14 (50.0%) post-LASIK dry eyes. The InflammaDry was positive in 8/14 (57.1%) post-LASIK eyes. All positive cases had tear film MMP-9 levels ≥38.03 ng/mL. Agreement between InflammaDry and MMP-9 was excellent with Cohen κ value of 0.857 in post-LASIK dry eyes. Only half of post-LASIK dry eyes were found to have significant inflammation associated with elevated MMP-9. The OSDI is useful to non-specifically identify patients with symptomatic dry eye while the InflammaDry determined which patients with dry eye were associated with significant inflammation that may guide therapeutic management decisions. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Infrared ocular thermography in dogs with and without keratoconjunctivitis sicca.
Biondi, Flávia; Dornbusch, Peterson T; Sampaio, Manuella; Montiani-Ferreira, Fabiano
2015-01-01
Infrared thermography was used to measure temperature differences of the corneal surface between nasal and temporal limbus regions and central cornea of normal dogs and dogs with keratoconjunctivitis sicca (KCS), in order to establish temperature values in normal canine eyes and in patients with decreased Schirmer tear tests (STT) values. Dogs investigated were all either patients seen at the Veterinary Teaching Hospital of Federal University of Paraná or normal dogs that belonged to the same institution. STT were performed in all eyes. A total of 40 control eyes (STT ≥15 mm/min) and 20 eyes with low STT values (STT ≤14 mm/min) were examined. The mean STT value for eyes with normal STT values was 22.9 ± 3.9 mm/min (mean ± standard deviation), and the mean STT value for eyes with low STT value was 7.2 ± 4.8 mm/min. The mean corneal temperature was significantly lower in eyes with low STT values than in control eyes (P < 0.0001). The following significant correlations were found: (i) Schirmer and breakup time (BUT) (P = 0.0001, r = 0.5); (ii) STT values and corneal surface temperature (P = 0.001, r = 0.256); (iii) STT values and age (P = 0.0001, r = -0.448); (iv) age and corneal surface temperature (P = 0.0001, r = -0.281); and (v) BUT and corneal surface temperature (P = 0.0001, r = 0.36). Thermography is a method that can differentiate between eyes with normal and abnormal STT values. In the future, thermography might be incorporated as part of the ophthalmic examination and perhaps become a popular ancillary test for the diagnoses of ocular surface disorders. © 2013 American College of Veterinary Ophthalmologists.
MAPK Target Sites of Eyes Absent Are Not Required for Eye Development or Survival in Drosophila
Jusiak, Barbara; Abulimiti, Abuduaini; Haelterman, Nele; Chen, Rui; Mardon, Graeme
2012-01-01
Eyes absent (Eya) is a highly conserved transcription cofactor and protein phosphatase that plays an essential role in eye development and survival in Drosophila. Ectopic eye induction assays using cDNA transgenes have suggested that mitogen activated protein kinase (MAPK) activates Eya by phosphorylating it on two consensus target sites, S402 and S407, and that this activation potentiates the ability of Eya to drive eye formation. However, this mechanism has never been tested in normal eye development. In the current study, we generated a series of genomic rescue transgenes to investigate how loss- and gain-of-function mutations at these two MAPK target sites within Eya affect Drosophila survival and normal eye formation: eya+GR, the wild-type control; eyaSAGR, which lacks phosphorylation at the two target residues; and eyaSDEGR, which contains phosphomimetic amino acids at the same two residues. Contrary to the previous studies in ectopic eye development, all eya genomic transgenes tested rescue both eye formation and survival equally effectively. We conclude that, in contrast to ectopic eye formation, MAPK-mediated phosphorylation of Eya on S402 and S407 does not play a role in normal development. This is the first study in Drosophila to evaluate the difference in outcomes between genomic rescue and ectopic cDNA-based overexpression of the same gene. These findings indicate similar genomic rescue strategies may prove useful for re-evaluating other long-standing Drosophila developmental models. PMID:23251383
Mutation of SALL2 causes recessive ocular coloboma in humans and mice
Kelberman, Daniel; Islam, Lily; Lakowski, Jörn; Bacchelli, Chiara; Chanudet, Estelle; Lescai, Francesco; Patel, Aara; Stupka, Elia; Buck, Anja; Wolf, Stephan; Beales, Philip L.; Jacques, Thomas S.; Bitner-Glindzicz, Maria; Liasis, Alki; Lehmann, Ordan J.; Kohlhase, Jürgen; Nischal, Ken K.; Sowden, Jane C.
2014-01-01
Ocular coloboma is a congenital defect resulting from failure of normal closure of the optic fissure during embryonic eye development. This birth defect causes childhood blindness worldwide, yet the genetic etiology is poorly understood. Here, we identified a novel homozygous mutation in the SALL2 gene in members of a consanguineous family affected with non-syndromic ocular coloboma variably affecting the iris and retina. This mutation, c.85G>T, introduces a premature termination codon (p.Glu29*) predicted to truncate the SALL2 protein so that it lacks three clusters of zinc-finger motifs that are essential for DNA-binding activity. This discovery identifies SALL2 as the third member of the Drosophila homeotic Spalt-like family of developmental transcription factor genes implicated in human disease. SALL2 is expressed in the developing human retina at the time of, and subsequent to, optic fissure closure. Analysis of Sall2-deficient mouse embryos revealed delayed apposition of the optic fissure margins and the persistence of an anterior retinal coloboma phenotype after birth. Sall2-deficient embryos displayed correct posterior closure toward the optic nerve head, and upon contact of the fissure margins, dissolution of the basal lamina occurred and PAX2, known to be critical for this process, was expressed normally. Anterior closure was disrupted with the fissure margins failing to meet, or in some cases misaligning leading to a retinal lesion. These observations demonstrate, for the first time, a role for SALL2 in eye morphogenesis and that loss of function of the gene causes ocular coloboma in humans and mice. PMID:24412933
Hayashi, Ken; Yoshida, Motoaki; Manabe, Shin-Ichi; Yoshimura, Koichi
2014-01-01
To compare changes in intraocular pressure (IOP) immediately after clear corneal incision (CCI) cataract surgery between eyes in which IOP was adjusted to a high or normal range at the conclusion of surgery. Hayashi Eye Hospital, Fukuoka, Japan. Comparative case series. Either eye of patients scheduled for phacoemulsification was randomized to 1 of 2 groups as follows: eyes that were to be adjusted to (1) high IOP (22 to 40 mm Hg) or (2) normal IOP (10 to 21 mm Hg). The IOP was measured using a rebound tonometer preoperatively; at the conclusion of surgery; and 15, 30, 60, 120, and 180 minutes and 24 hours postoperatively. The Seidel test and anterior segment optical coherence tomography (AS-OCT) were performed. The mean IOP at the conclusion of surgery was 31.3 mm Hg in the high IOP group and 17.1 mm Hg in the normal IOP group. The IOP decreased to approximately 15 mm Hg by 15 minutes and did not change until 60 minutes in either group. The mean IOP did not differ significantly between groups throughout the observation period (P ≥.0634). Hypotony of 5 mm Hg or less was not detected in any eye. The Seidel test was negative and based on AS-OCT, the wound was closed at 60 minutes in all eyes. After adjusting IOP to a high or normal range, the IOP normalized within 15 minutes postoperatively and was stable for 24 hours. The wound was closed within 60 minutes postoperatively. Copyright © 2013 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Huang, Jinhai; Liao, Na; Savini, Giacomo; Li, Yuanguang; Bao, Fangjun; Yu, Ye; Yu, Ayong; Wang, Qinmei
2015-02-01
To determine the repeatability and reproducibility of measurements of central corneal thickness (CCT) using optical low-coherence reflectometry (Lenstar LS900; Haag Streit) in normal eyes and post-femtosecond laser in situ keratomileusis (post-FS-LASIK) eyes and evaluate their agreement with ultrasound (US) pachymetry. CCT was measured using Lenstar and US pachymetry sequentially in normal and post-FS-LASIK eyes by 2 experienced observers. Intraoperator repeatability and interoperator reproducibility were assessed by within-subject standard deviation, test-retest repeatability, coefficient of variation (CoV), and intraclass correlation coefficient. Paired t-tests and Bland-Altman plots were used for analyzing agreement between the 2 devices. In this study, 55 healthy subjects and 50 post-FS-LASIK patients were recruited. Test-retest repeatability of Lenstar was within 10 μm, CoV was less than 1.0%, and intraclass correlation coefficient was more than 0.9 in both normal and post-FS-LASIK groups. Mean difference between these methods was 1.4 ± 4.2 μm and -1.7 ± 5.4 μm, respectively. Moreover, measurements of CCT showed narrow 95% limits of agreement (range, normal group: -6.8 and 9.6 μm; post-FS-LASIK group: -12.4 and 8.9 μm), which implied good agreement. Measurements of CCT using Lenstar showed excellent intraoperator repeatability and interoperator reproducibility both in normal eyes and post-FS-LASIK eyes. Measurements of CCT using Lenstar and US pachymetry showed good agreement and both can be used interchangeably.
Kee, Changwon; Cho, Changhwan
2003-06-01
The authors investigated the correlation between visual field defects detected by automated perimetry and the thickness of the retinal nerve fiber layer measured with optical coherence tomography, and examined whether there is a decrease in retinal nerve fiber layer thickness in the apparently normal hemifield of glaucomatous eyes. Forty-one patients with glaucoma and 41 normal control subjects were included in this study. Statistical correlations between the sum of the total deviation of 37 stimuli of each hemifield and the ratio of decrease in retinal nerve fiber layer thickness were evaluated. The statistical difference between the retinal nerve fiber layer thickness of the apparently normal hemifield in glaucomatous eyes and that of the corresponding hemifield in normal subjects was also evaluated. There was a statistically significant correlation in the sum of the total deviation and retinal nerve fiber layer thickness decrease ratio (superior hemifield, P = 0.001; inferior hemifield, P = 0.003). There was no significant decrease in retinal nerve fiber layer thickness in the area that corresponded to the normal visual field in the hemifield defect with respect to the horizontal meridian in glaucomatous eyes (superior side, P = 0.148; inferior side, P = 0.341). Optical coherence tomography was capable of demonstrating and measuring retinal nerve fiber layer abnormalities. No changes in the retinal nerve fiber layer thickness of the apparently normal hemifield were observed in glaucomatous eyes.
Kato, Takafumi; Toyota, Risa; Haraki, Shingo; Yano, Hiroyuki; Higashiyama, Makoto; Ueno, Yoshio; Yano, Hiroshi; Sato, Fumihiko; Yatani, Hirofumi; Yoshida, Atsushi
2017-09-27
Rhythmic masticatory muscle activity can be a normal variant of oromotor activity, which can be exaggerated in patients with sleep bruxism. However, few studies have tested the possibility in naturally sleeping animals to study the neurophysiological mechanisms of rhythmic masticatory muscle activity. This study aimed to investigate the similarity of cortical, cardiac and electromyographic manifestations of rhythmic masticatory muscle activity occurring during non-rapid eye movement sleep between guinea pigs and human subjects. Polysomnographic recordings were made in 30 freely moving guinea pigs and in eight healthy human subjects. Burst cycle length, duration and activity of rhythmic masticatory muscle activity were compared with those for chewing. The time between R-waves in the electrocardiogram (RR interval) and electroencephalogram power spectrum were calculated to assess time-course changes in cardiac and cortical activities in relation to rhythmic masticatory muscle activity. In animals, in comparison with chewing, rhythmic masticatory muscle activity had a lower burst activity, longer burst duration and longer cycle length (P < 0.05), and greater variabilities were observed (P < 0.05). Rhythmic masticatory muscle activity occurring during non-rapid eye movement sleep [median (interquartile range): 5.2 (2.6-8.9) times per h] was preceded by a transient decrease in RR intervals, and was accompanied by a transient decrease in delta elelctroencephalogram power. In humans, masseter bursts of rhythmic masticatory muscle activity were characterized by a lower activity, longer duration and longer cycle length than those of chewing (P < 0.05). Rhythmic masticatory muscle activity during non-rapid eye movement sleep [1.4 (1.18-2.11) times per h] was preceded by a transient decrease in RR intervals and an increase in cortical activity. Rhythmic masticatory muscle activity in animals had common physiological components representing transient arousal-related rhythmic jaw motor activation in comparison to human subjects. © 2017 European Sleep Research Society.
Assessment of visual disability using visual evoked potentials.
Jeon, Jihoon; Oh, Seiyul; Kyung, Sungeun
2012-08-06
The purpose of this study is to validate the use of visual evoked potential (VEP) to objectively quantify visual acuity in normal and amblyopic patients, and determine if it is possible to predict visual acuity in disability assessment to register visual pathway lesions. A retrospective chart review was conducted of patients diagnosed with normal vision, unilateral amblyopia, optic neuritis, and visual disability who visited the university medical center for registration from March 2007 to October 2009. The study included 20 normal subjects (20 right eyes: 10 females, 10 males, ages 9-42 years), 18 unilateral amblyopic patients (18 amblyopic eyes, ages 19-36 years), 19 optic neuritis patients (19 eyes: ages 9-71 years), and 10 patients with visual disability having visual pathway lesions. Amplitude and latencies were analyzed and correlations with visual acuity (logMAR) were derived from 20 normal and 18 amblyopic subjects. Correlation of VEP amplitude and visual acuity (logMAR) of 19 optic neuritis patients confirmed relationships between visual acuity and amplitude. We calculated the objective visual acuity (logMAR) of 16 eyes from 10 patients to diagnose the presence or absence of visual disability using relations derived from 20 normal and 18 amblyopic eyes. Linear regression analyses between amplitude of pattern visual evoked potentials and visual acuity (logMAR) of 38 eyes from normal (right eyes) and amblyopic (amblyopic eyes) subjects were significant [y = -0.072x + 1.22, x: VEP amplitude, y: visual acuity (logMAR)]. There were no significant differences between visual acuity prediction values, which substituted amplitude values of 19 eyes with optic neuritis into function. We calculated the objective visual acuity of 16 eyes of 10 patients to diagnose the presence or absence of visual disability using relations of y = -0.072x + 1.22 (-0.072). This resulted in a prediction reference of visual acuity associated with malingering vs. real disability in a range >5.77 μV. The results could be useful, especially in cases of no obvious pale disc with trauma. Visual acuity quantification using absolute value of amplitude in pattern visual evoked potentials was useful in confirming subjective visual acuity for cutoff values >5.77 μV in disability evaluation to discriminate the malingering from real disability.
Assessment of visual disability using visual evoked potentials
2012-01-01
Background The purpose of this study is to validate the use of visual evoked potential (VEP) to objectively quantify visual acuity in normal and amblyopic patients, and determine if it is possible to predict visual acuity in disability assessment to register visual pathway lesions. Methods A retrospective chart review was conducted of patients diagnosed with normal vision, unilateral amblyopia, optic neuritis, and visual disability who visited the university medical center for registration from March 2007 to October 2009. The study included 20 normal subjects (20 right eyes: 10 females, 10 males, ages 9–42 years), 18 unilateral amblyopic patients (18 amblyopic eyes, ages 19–36 years), 19 optic neuritis patients (19 eyes: ages 9–71 years), and 10 patients with visual disability having visual pathway lesions. Amplitude and latencies were analyzed and correlations with visual acuity (logMAR) were derived from 20 normal and 18 amblyopic subjects. Correlation of VEP amplitude and visual acuity (logMAR) of 19 optic neuritis patients confirmed relationships between visual acuity and amplitude. We calculated the objective visual acuity (logMAR) of 16 eyes from 10 patients to diagnose the presence or absence of visual disability using relations derived from 20 normal and 18 amblyopic eyes. Results Linear regression analyses between amplitude of pattern visual evoked potentials and visual acuity (logMAR) of 38 eyes from normal (right eyes) and amblyopic (amblyopic eyes) subjects were significant [y = −0.072x + 1.22, x: VEP amplitude, y: visual acuity (logMAR)]. There were no significant differences between visual acuity prediction values, which substituted amplitude values of 19 eyes with optic neuritis into function. We calculated the objective visual acuity of 16 eyes of 10 patients to diagnose the presence or absence of visual disability using relations of y = −0.072x + 1.22 (−0.072). This resulted in a prediction reference of visual acuity associated with malingering vs. real disability in a range >5.77 μV. The results could be useful, especially in cases of no obvious pale disc with trauma. Conclusions Visual acuity quantification using absolute value of amplitude in pattern visual evoked potentials was useful in confirming subjective visual acuity for cutoff values >5.77 μV in disability evaluation to discriminate the malingering from real disability. PMID:22866948
Successful Gene Therapy in the RPGRIP1-deficient Dog: a Large Model of Cone–Rod Dystrophy
Lhériteau, Elsa; Petit, Lolita; Weber, Michel; Le Meur, Guylène; Deschamps, Jack-Yves; Libeau, Lyse; Mendes-Madeira, Alexandra; Guihal, Caroline; François, Achille; Guyon, Richard; Provost, Nathalie; Lemoine, Françoise; Papal, Samantha; El-Amraoui, Aziz; Colle, Marie-Anne; Moullier, Philippe; Rolling, Fabienne
2014-01-01
For the development of new therapies, proof-of-concept studies in large animal models that share clinical features with their human counterparts represent a pivotal step. For inherited retinal dystrophies primarily involving photoreceptor cells, the efficacy of gene therapy has been demonstrated in canine models of stationary cone dystrophies and progressive rod–cone dystrophies but not in large models of progressive cone–rod dystrophies, another important cause of blindness. To address the last issue, we evaluated gene therapy in the retinitis pigmentosa GTPase regulator interacting protein 1 (RPGRIP1)-deficient dog, a model exhibiting a severe cone–rod dystrophy similar to that seen in humans. Subretinal injection of AAV5 (n = 5) or AAV8 (n = 2) encoding the canine Rpgrip1 improved photoreceptor survival in transduced areas of treated retinas. Cone function was significantly and stably rescued in all treated eyes (18–72% of those recorded in normal eyes) up to 24 months postinjection. Rod function was also preserved (22–29% of baseline function) in four of the five treated dogs up to 24 months postinjection. No detectable rod function remained in untreated contralateral eyes. More importantly, treatment preserved bright- and dim-light vision. Efficacy of gene therapy in this large animal model of cone–rod dystrophy provides great promise for human treatment. PMID:24091916
Speer, Colenso M; Sun, Chao; Liets, Lauren C; Stafford, Ben K; Chapman, Barbara; Cheng, Hwai-Jong
2014-11-07
Spontaneous retinal activity (SRA) is important during eye-specific segregation within the dorsal lateral geniculate nucleus (dLGN), but the feature(s) of activity critical for retinogeniculate refinement are controversial. Pharmacologically or genetically manipulating cholinergic signaling during SRA perturbs correlated retinal ganglion cell (RGC) spiking and disrupts eye-specific retinofugal refinement in vivo, consistent with an instructive role for SRA during visual system development. Paradoxically, ablating the starburst amacrine cells (SACs) that generate cholinergic spontaneous activity disrupts correlated RGC firing without impacting retinal activity levels or eye-specific segregation in the dLGN. Such experiments suggest that patterned SRA during retinal waves is not critical for eye-specific refinement and instead, normal activity levels are permissive for retinogeniculate development. Here we revisit the effects of ablating the cholinergic network during eye-specific segregation and show that SAC ablation disrupts, but does not eliminate, retinal waves with no concomitant impact on normal eye-specific segregation in the dLGN. We induced SAC ablation in postnatal ferret pups beginning at birth by intraocular injection of a novel immunotoxin selective for the ferret vesicular acetylcholine transporter (Ferret VAChT-Sap). Through dual-patch whole-cell and multi-electrode array recording we found that SAC ablation altered SRA patterns and led to significantly smaller retinal waves compared with controls. Despite these defects, eye-specific segregation was normal. Further, interocular competition for target territory in the dLGN proceeded in cases where SAC ablation was asymmetric in the two eyes. Our data demonstrate normal eye-specific retinogeniculate development despite significant abnormalities in patterned SRA. Comparing our current results with earlier studies suggests that defects in retinal wave size, absolute levels of SRA, correlations between RGC pairs, RGC burst frequency, high frequency RGC firing during bursts, and the number of spikes per RGC burst are each uncorrelated with abnormalities in eye-specific segregation in the dLGN. An increase in the fraction of asynchronous spikes occurring outside of bursts and waves correlates with eye-specific segregation defects in studies reported to date. These findings highlight the relative importance of different features of SRA while providing additional constraints for computational models of Hebbian plasticity mechanisms in the developing visual system.
Persistent Seroconversion after Accidental Eye Exposure to Calcifying Nanoparticles
NASA Technical Reports Server (NTRS)
Ciftcioglu, Neva; Aho, Katja M.; McKay, David S.; Kajander, E. Olavi
2007-01-01
Biosafety of nanomaterials has attracted much attention recently. We report here a case where accidental human eye exposure to biogenic nanosized calcium phosphate in the form of calcifying nanoparticles (CNP) raised a strong IgG immune response against proteins carried by CNP. The antibody titer has persisted over ten years at the high level. The IgG was detected by ELISA using CNPs propagated in media containing bovine and human serum as antigen. The exposure incident occurred to a woman scientist (WS) at a research laboratory in Finland at 1993. CNP, also termed "nanobacteria", is a unique self-replicating agent that has not been fully characterized and no data on biohazards were available at that time. Before the accident, her serum samples were negative for both CNP antigen and anti-CNP antibody using specific ELISA tests (Nanobac Oy, Kuopio, Finland). The accident occurred while WS was harvesting CNP cultures. Due to a high pressure in pipetting, CNP pellet splashed into her right eye. Both eyes were immediately washed with water and saline. The following days there was irritation and redness in the right eye. These symptoms disappeared within two weeks without any treatment. Three months after the accident, blood and urine samples of WS were tested for CNP cultures (2), CNP-specific ELISA tests, and blood cell counts. Blood cell counts were normal, CNP antigen and culture tests were negative. A high IgG anti-CNP antibody titer was detected (see Figure). The antibodies of this person have been used thereafter as positive control and standard in ELISA manufacturing (Nano-Sero IgG ELISA, Nanobac Oy, Kuopio, Finland).
Rotating Scheimpflug Imaging Indices in Different Grades of Keratoconus
2016-01-01
Purpose. To evaluate accuracy of various Keratoconus (KC) screening indices, in relation to Topographic Keratoconus (TKC) grading. Setting. Al Watany Eye Hospital, Cairo, Egypt. Methods. Data of 103 normal (group 1) and 73 KC eyes (group 2), imaged by Pentacam (branded as Allegro Oculyzer), were analysed. Group 2 was divided into 2a: 14 eyes (TKC = 1, early KC), 2b: 25 eyes (TKC = 1 to 2 or 2, moderate KC), and 2c: 34 eyes (TKC = 2 to 3 up to 4, severe KC). Participants were followed up for six years to confirm diagnosis. Area under the receiver operating characteristic curve (AUROC) was calculated for evaluated curvature, elevation, and pachymetry indices with various reference shapes at different diameters. Results. When comparing normal to KC eyes, ten indices had significantly higher AUROC. Only five of them had significantly higher AUROC in early KC compared to normal corneas: Pachymetry Progression Index- (PPI-) Maximum (Max), Ambrósio's Relational Thickness- (ART-) Max, PPI-Max minus PPI-Minimum (Min), central corneal thickness (CCT), and diagonal decentration of thinnest point from the apex (AUROC = 0.690, 0.690, 0.687, 0.683, and 0.674, resp.). Conclusion. Generally, ten pachymetry and elevation-based indices had significantly higher AUROC. Five indices had statistically significant high AUROC when comparing early KC to normal corneas. PMID:27579178
Differences in intermittent postural control between normal-weight and obese children.
Villarrasa-Sapiña, Israel; García-Massó, Xavier; Serra-Añó, Pilar; Garcia-Lucerga, Consolación; Gonzalez, Luis-Millán; Lurbe, Empar
2016-09-01
The main objective of this study was to determine differences in postural control between obese and non-obese children. The study design was cross-sectional, prospective, between-subjects. Postural control variables were obtained from a group of obese children and a normal-weight control group under two different postural conditions: bipedal standing position with eyes open and bipedal standing with eyes closed. Variables were obtained for each balance condition using time domain and sway-density plot analysis of the center of pressure signals acquired by means of a force plate. Pairwise comparisons revealed significant differences between obese and normal-weight children in mean velocity in antero-posterior and medio-lateral directions, ellipse area and mean distance with both eyes open and eyes closed. Normal-weight subjects obtained lower values in all these variables than obese subjects. Furthermore, there were differences between both groups in mean peaks with eyes open and in mean time with eyes closed. Alterations were detected in the intermittent postural control in obese children. According to the results obtained, active anticipatory control produces higher center of pressure displacement responses in obese children and the periods during which balance is maintained by passive control and reflex mechanisms are of shorter duration. Copyright © 2016 Elsevier B.V. All rights reserved.
Negro, Juan J; Carmen Blázquez, M; Galván, Ismael
2017-01-01
Human populations and breeds of domestic animals are composed of individuals with a multiplicity of eye (= iris) colorations. Some wild birds and mammals may have intraspecific eye color variability, but this variation seems to be due to the developmental stage of the individual, its breeding status, and/or sexual dimorphism. In other words, eye colour tends to be a species-specific trait in wild animals, and the exceptions are species in which individuals of the same age group or gender all develop the same eye colour. Domestic animals, by definition, include bird and mammal species artificially selected by humans in the last few thousand years. Humans themselves may have acquired a diverse palette of eye colors, likewise in recent evolutionary time, in the Mesolithic or in the Upper Paleolithic. We posit two previously unrecognized hypotheses regarding eye color variation: 1) eye coloration in wild animals of every species tends to be a fixed trait. 2) Humans and domestic animal populations, on the contrary, have eyes of multiple colors. Sexual selection has been invoked for eye color variation in humans, but this selection mode does not easily apply in domestic animals, where matings are controlled by the human breeder. Eye coloration is polygenic in humans. We wish to investigate the genetics of eye color in other animals, as well as the ecological correlates. Investigating the origin and function of eye colors will shed light on the reason why some species may have either light-colored irises (e.g., white, yellow or light blue) or dark ones (dark red, brown or black). The causes behind the vast array of eye colors across taxa have never been thoroughly investigated, but it may well be that all Darwinian selection processes are at work: sexual selection in humans, artificial selection for domestic animals, and natural selection (mainly) for wild animals.
SLITRK6 mutations cause myopia and deafness in humans and mice
Tekin, Mustafa; Chioza, Barry A.; Matsumoto, Yoshifumi; Diaz-Horta, Oscar; Cross, Harold E.; Duman, Duygu; Kokotas, Haris; Moore-Barton, Heather L.; Sakoori, Kazuto; Ota, Maya; Odaka, Yuri S.; Foster, Joseph; Cengiz, F. Basak; Tokgoz-Yilmaz, Suna; Tekeli, Oya; Grigoriadou, Maria; Petersen, Michael B.; Sreekantan-Nair, Ajith; Gurtz, Kay; Xia, Xia-Juan; Pandya, Arti; Patton, Michael A.; Young, Juan I.; Aruga, Jun; Crosby, Andrew H.
2013-01-01
Myopia is by far the most common human eye disorder that is known to have a clear, albeit poorly defined, heritable component. In this study, we describe an autosomal-recessive syndrome characterized by high myopia and sensorineural deafness. Our molecular investigation in 3 families led to the identification of 3 homozygous nonsense mutations (p.R181X, p.S297X, and p.Q414X) in SLIT and NTRK-like family, member 6 (SLITRK6), a leucine-rich repeat domain transmembrane protein. All 3 mutant SLITRK6 proteins displayed defective cell surface localization. High-resolution MRI of WT and Slitrk6-deficient mouse eyes revealed axial length increase in the mutant (the endophenotype of myopia). Additionally, mutant mice exhibited auditory function deficits that mirrored the human phenotype. Histological investigation of WT and Slitrk6-deficient mouse retinas in postnatal development indicated a delay in synaptogenesis in Slitrk6-deficient animals. Taken together, our results showed that SLITRK6 plays a crucial role in the development of normal hearing as well as vision in humans and in mice and that its disruption leads to a syndrome characterized by severe myopia and deafness. PMID:23543054
Knowledge and attitude of guardians towards eye health of primary school pupils in Ilorin, Nigeria.
Ayanniyi, A A; Olatunji, F O; Mahmoud, A O; Ayanniyi, R O
2010-03-01
To determine guardians' knowledge and attitude towards pupils' eye health and draw implication for designing children-oriented ocular health messages. A survey of 1,393 guardians selected through multistage random sampling in Ilorin, Nigeria. Using structured questionnaire, information sought included guardians' demographic characteristics, relationship to pupils, occupation, awareness of eye specialists, perception of normal vision, pupils' eye complaints, and ways of treating children eye conditions. Data analysis was done with SPSS 12.0.1. The test of significance was performed using Chi square test and significance was taken at p < 0.05. Guardians comprised 689 (49.4%) males and 704 (50.6%) females, mean age 43.61 SD 11.45. Most (88.54%) were pupils' parents and (11.46%) were relations (n=1,318); (55.15%) were in low-paying occupations (n=1,311); (87.92%) were aware of eye specialists, (12.08%) unaware, (n=1192); (97.27%) adjudged normal vision at least important, (2.73%) not important (n=1,174). Pupils' eye complaints (n=914) included pain (26.04%), itching (24.73%), redness (21.12%), discharge (8.53%), blur vision (8.21%), photophobia (7.33%) and lacrimation (4.05%). Guardians (n=1,069) managed pupils' eye diseases using hospital treatment (61.65%), neglect (21.33%), self medication (9.26%) and traditional medication (7.76%). There were no significant associations between guardians' ways of managing pupils' eye diseases and their views on normal vision (p = 0.940); awareness of eye care specialists (p = 0.952); and economic occupational grouping (p = 0.959). The negative implications of neglecting eye diseases and use of self and harmful traditional eye-medications by some of the guardians need to be discouraged by appropriate eye health education.
Iris autofluorescence in Fuchs' heterochromic uveitis.
Liu, Qian; Jia, Yading; Zhang, Suhua; Xie, Juan; Chang, Xin; Hou, Jia; Li, Gaiyun; Koch, Douglas D; Wang, Li
2016-10-01
To explore the characteristic autofluorescence patterns of iris depigmentation in eyes diagnosed with Fuchs' heterochromic uveitis (FHU). Near-infrared autofluorescence images and colour images of iris were taken in 21 eyes of 21 patients with FHU, 30 eyes of 15 normal subjects, 30 eyes of 15 normal age-related iris atrophy and 33 eyes of 20 patients with uveitis other than FHU. The confocal scanning laser ophthalmoscope (Heidelberg Retina Angiograph 2, HRA2) was used for melanin-related autofluorescence imaging. The indocyanine green angiography mode of HRA2 was applied for near-infrared laser imaging, and the wavelength of the excitation laser was 795 nm. Iris colour images were also taken with the slit lamp. In normal iris, moderately intense autofluorescence was noted for the pigment ruff at the pupillary border, the crests in the pupillary zone and the collarette; and there was mild autofluorescence in the ciliary zone. In eyes with age-related iris atrophy and uveitis, much less autofluorescence was seen than the healthy normal irides. In eyes with FHU, there was moderate but discontinuous autofluorescence in the pigment ruff, a petaloid pattern of autofluorescence in the pupillary zone, moderate autofluorescence in the collarette and reticular pattern of autofluorescence in the ciliary zone. Characteristic autofluorescence patterns appeared in eyes diagnosed with FHU. Near-infrared autofluorescence is a promising objective technique to document the iris changes in FHU. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Retinal oxygen saturation evaluation by multi-spectral fundus imaging
NASA Astrophysics Data System (ADS)
Khoobehi, Bahram; Ning, Jinfeng; Puissegur, Elise; Bordeaux, Kimberly; Balasubramanian, Madhusudhanan; Beach, James
2007-03-01
Purpose: To develop a multi-spectral method to measure oxygen saturation of the retina in the human eye. Methods: Five Cynomolgus monkeys with normal eyes were anesthetized with intramuscular ketamine/xylazine and intravenous pentobarbital. Multi-spectral fundus imaging was performed in five monkeys with a commercial fundus camera equipped with a liquid crystal tuned filter in the illumination light path and a 16-bit digital camera. Recording parameters were controlled with software written specifically for the application. Seven images at successively longer oxygen-sensing wavelengths were recorded within 4 seconds. Individual images for each wavelength were captured in less than 100 msec of flash illumination. Slightly misaligned images of separate wavelengths due to slight eye motion were registered and corrected by translational and rotational image registration prior to analysis. Numerical values of relative oxygen saturation of retinal arteries and veins and the underlying tissue in between the artery/vein pairs were evaluated by an algorithm previously described, but which is now corrected for blood volume from averaged pixels (n > 1000). Color saturation maps were constructed by applying the algorithm at each image pixel using a Matlab script. Results: Both the numerical values of relative oxygen saturation and the saturation maps correspond to the physiological condition, that is, in a normal retina, the artery is more saturated than the tissue and the tissue is more saturated than the vein. With the multi-spectral fundus camera and proper registration of the multi-wavelength images, we were able to determine oxygen saturation in the primate retinal structures on a tolerable time scale which is applicable to human subjects. Conclusions: Seven wavelength multi-spectral imagery can be used to measure oxygen saturation in retinal artery, vein, and tissue (microcirculation). This technique is safe and can be used to monitor oxygen uptake in humans. This work is original and is not under consideration for publication elsewhere.
Functional visual acuity in patients with successfully treated amblyopia: a pilot study.
Hoshi, Sujin; Hiraoka, Takahiro; Kotsuka, Junko; Sato, Yumiko; Izumida, Shinya; Kato, Atsuko; Ueno, Yuta; Fukuda, Shinichi; Oshika, Tetsuro
2017-06-01
The aim of this study was to use conventional visual acuity measurements to quantify the functional visual acuity (FVA) in eyes with successfully treated amblyopia, and to compare the findings with those for contralateral normal eyes. Nineteen patients (7 boys, 12 girls; age 7.5 ± 2.2 years) with successfully treated unilateral amblyopia and the same conventional decimal visual acuity in both eyes (better than 1.0) were enrolled. FVA, the visual maintenance ratio (VMR), maximum and minimum visual acuity, and the average response time were recorded for both eyes of all patients using an FVA measurement system. The differences in FVA values between eyes were analyzed. The mean LogMAR FVA scores, VMR (p < 0.001 for both), and the LogMAR maximum (p < 0.005) and minimum visual acuity (p < 0.001) were significantly poorer for the eyes with treated amblyopia than for the contralateral normal eyes. There was no significant difference in the average response time. Our results indicate that FVA and VMR were poorer for eyes with treated amblyopia than for normal eyes, even though the treatment for amblyopia was considered successful on the basis of conventional visual acuity measurements. These results suggest that visual function is impaired in eyes with amblyopia, regardless of treatment success, and that FVA measurements can provide highly valuable diagnosis and treatment information that is not readily provided by conventional visual acuity measurements.
NASA Astrophysics Data System (ADS)
Dierks, Karsten; Dieckmann, Matthias; Niederstrasser, Dirk; Schwartz, R.; Wegener, Alfred R.
1995-01-01
Laser light source powers of our instrument LEPOSIAR are minimized so that dynamic light scattering (DLS) measurements can be conducted with lowest intensity levels on human eye lenses (3.2 mW/cm2) within measurement times of 3 to 5 seconds. We describe an extension of DLS and an eye lens characterization along the optical axis (OA), revealing the molecular size ranges together with distributions found in lens regions parallel to the OA. The microstructures of various lens regions are separated by the analyzed radius distributions reflecting the visco-elastic properties of the eye lens. Detailed analysis and applied statistical categorization of results are described. The data obtained by DLS allow for an objective interpretation of opacity occurrences on molecular size range which are related to refraction anomalies. Apart from changes in color and fluorescence properties, the refractive anomalies can be assumed as the origin of the cataract. The bimodal radius distributions are characterized as a function of patient ages varying from 9 to 85 years. Our clinical study on 42 subjects proves a size decrease of the monomeric fraction with age, whereby their relative frequency of occurrence decreases. The larger polymeric radius fractions which are detected in lenses of all subjects increase with their age. An increase of protein polymer size is likely to be linked to the decrease of the (gamma) -crystallin fraction in old eye lens nuclei. Our preliminary analysis of clinical results is corresponding to the chemical gradients parallel to the OA of the lenses which are reported by O. Hockwin after examination on extracted eye lenses. The normalization of the lens densitometric data derived after Scheimpflug- photography against the protein size fraction analysis by DLS is performed. As a comparison mean between both techniques on identical eye lenses, an absorption corrected densitometry is conducted for the first time.
Allum, J H; Honegger, F
1993-01-01
Future developments of neuroprosthetic control will probably permit locomotion and posture to be maintained without the aid of crutches and will therefore require some form of balance control. Three fundamental questions will arise. First, the question of the location of imbalance-sensing transducers must be assessed. Secondly, the synergy, which is the relative amplitude and timing of muscle activity, and/or the strategy of joint torques required to re-establish a stable posture for different types of balance disturbances must be addressed. Thirdly, the control laws that map either trunk muscle activity or imbalance-sensing transducer outputs into multi-joint postural control of standing by paraplegic individuals must be generated. The most appropriate means of gathering the relevant information applicable to neuroprosthetic control systems is through the detailed analysis of normal and non-normal human models. In order to gain such detailed insights into normal balance control and its dependence on head angular and linear accelerations, the synergy and strategy of balance corrections in normal subjects or patients with vestibular deficits were investigated for two types of support surface perturbation, a dorsiflexion rotation (ROT) and a rearward translation (TRANS). These experimentally induced perturbations to upright stance were adjusted to cause equal amplitudes of ankle dorsiflexion, thus providing additional information about the role of lower leg proprioception on balance control. Synergies defined on the basis of peak cross-correlations of each recorded muscle's EMG to that of the largest muscle response were significantly different for TRANS and ROT. Translation synergies consisted of a sequential coactivation at several levels (soleus and abdominals some 30 msec before hamstrings, and trapezius some 15 msec before paraspinals), whereas the sequential activation of paraspinals and tibialis anterior dominated the balance synergy to ROT. Likewise, response strategies, defined using cross-correlations of joint torques, differed. That for TRANS was organised as a multi-link strategy with neck torques leading those of all other joints by 40 msec or more; hip joint lead ankle torques by 30 msec. That for ROT was organised around hip and ankle torques without a major correlation to neck torques. Vestibulary deficient subjects developed weaker synergies with respect to subjects with normal balance systems under eyes-open conditions and there was no clear synergy with eyes closed. Consequently, hip torques were delayed some 180 msec with respect to ankle torques, and correlations to neck torques were completely out of phase under eyes-closed conditions. Fundamental changes in TRANS synergies and strategies also occurred in vestibulary deficient subjects for eyes-open and eyes-closed conditions.(ABSTRACT TRUNCATED AT 400 WORDS)
Glutathione-related enzymes and the eye.
Ganea, Elena; Harding, John J
2006-01-01
Glutathione and the related enzymes belong to the defence system protecting the eye against chemical and oxidative stress. This review focuses on GSH and two key enzymes, glutathione reductase and glucose-6-phosphate dehydrogenase in lens, cornea, and retina. Lens contains a high concentration of reduced glutathione, which maintains the thiol groups in the reduced form. These contribute to lens complete transparency as well as to the transparent and refractive properties of the mammalian cornea, which are essential for proper image formation on the retina. In cornea, gluthatione also plays an important role in maintaining normal hydration level, and in protecting cellular membrane integrity. In retina, glutathione is distributed in the different types of retinal cells. Intracellular enzyme, glutathione reductase, involved in reducing the oxidized glutathione has been found at highest activity in human and primate lenses, as compared to other species. Besides the enzymes directly involved in maintaining the normal redox status of the cell, glucose-6-phosphate dehydrogenase which catalyzes the first reaction of the pentose phosphate pathway, plays a key role in protection of the eye against reactive oxygen species. Cornea has a high activity of the pentose phosphate pathway and glucose-6-phosphate dehydrogenase activity. Glycation, the non-enzymic reaction between a free amino group in proteins and a reducing sugar, slowly inactivates gluthathione-related and other enzymes. In addition, glutathione can be also glycated. The presence of glutathione, and of the related enzymes has been also reported in other parts of the eye, such as ciliary body and trabecular meshwork, suggesting that the same enzyme systems are present in all tissues of the eye to generate NADPH and to maintain gluthatione in the reduced form. Changes of glutathione and related enzymes activity in lens, cornea, retina and other eye tissues, occur with ageing, cataract, diabetes, irradiation and administration of some drugs.
Han, Ji Yun; Kang, Boram; Eom, Youngsub; Kim, Hyo Myung; Song, Jong Suk
2017-05-01
To compare the effect of exposure to particulate matter on the ocular surface of normal and experimental dry eye (EDE) rat models. Titanium dioxide (TiO2) nanoparticles were used as the particulate matter. Rats were divided into 4 groups: normal control group, TiO2 challenge group of the normal model, EDE control group, and TiO2 challenge group of the EDE model. After 24 hours, corneal clarity was compared and tear samples were collected for quantification of lactate dehydrogenase, MUC5AC, and tumor necrosis factor-α concentrations. The periorbital tissues were used to evaluate the inflammatory cell infiltration and detect apoptotic cells. The corneal clarity score was greater in the EDE model than in the normal model. The score increased after TiO2 challenge in each group compared with each control group (normal control vs. TiO2 challenge group, 0.0 ± 0.0 vs. 0.8 ± 0.6, P = 0.024; EDE control vs. TiO2 challenge group, 2.2 ± 0.6 vs. 3.8 ± 0.4, P = 0.026). The tear lactate dehydrogenase level and inflammatory cell infiltration on the ocular surface were higher in the EDE model than in the normal model. These measurements increased significantly in both normal and EDE models after TiO2 challenge. The tumor necrosis factor-α levels and terminal deoxynucleotidyl transferase-mediated dUTP nick end labeling-positive cells were also higher in the EDE model than in the normal model. TiO2 nanoparticle exposure on the ocular surface had a more prominent effect in the EDE model than it did in the normal model. The ocular surface of dry eyes seems to be more vulnerable to fine dust of air pollution than that of normal eyes.
What interests them in the pictures?--differences in eye-tracking between rhesus monkeys and humans.
Hu, Ying-Zhou; Jiang, Hui-Hui; Liu, Ci-Rong; Wang, Jian-Hong; Yu, Cheng-Yang; Carlson, Synnöve; Yang, Shang-Chuan; Saarinen, Veli-Matti; Rizak, Joshua D; Tian, Xiao-Guang; Tan, Hen; Chen, Zhu-Yue; Ma, Yuan-Ye; Hu, Xin-Tian
2013-10-01
Studies estimating eye movements have demonstrated that non-human primates have fixation patterns similar to humans at the first sight of a picture. In the current study, three sets of pictures containing monkeys, humans or both were presented to rhesus monkeys and humans. The eye movements on these pictures by the two species were recorded using a Tobii eye-tracking system. We found that monkeys paid more attention to the head and body in pictures containing monkeys, whereas both monkeys and humans paid more attention to the head in pictures containing humans. The humans always concentrated on the eyes and head in all the pictures, indicating the social role of facial cues in society. Although humans paid more attention to the hands than monkeys, both monkeys and humans were interested in the hands and what was being done with them in the pictures. This may suggest the importance and necessity of hands for survival. Finally, monkeys scored lower in eye-tracking when fixating on the pictures, as if they were less interested in looking at the screen than humans. The locations of fixation in monkeys may provide insight into the role of eye movements in an evolutionary context.
Xin, Daiyan; Talamini, Christine L; Raza, Ali S; de Moraes, Carlos Gustavo V; Greenstein, Vivienne C; Liebmann, Jeffrey M; Ritch, Robert; Hood, Donald C
2011-09-09
To better understand hypodense regions (holes) that appear in the retinal nerve fiber layer (RNFL) of frequency-domain optical coherence tomography (fdOCT) scans of patients with glaucoma and glaucoma suspects. Peripapillary circle (1.7-mm radius) and cube optic disc fdOCT scans were obtained on 208 eyes from 110 patients (57.4 ± 13.2 years) with glaucomatous optic neuropathy (GON) and 45 eyes of 45 controls (48.0 ± 12.6 years) with normal results of fundus examination. Holes in the RNFL were identified independently by two observers on the circle scans. Holes were found in 33 (16%) eyes of 28 (25%) patients; they were not found in any of the control eyes. Twenty-four eyes had more than one hole. Although some holes were relatively large, others were small. In general, the holes were located adjacent to blood vessels; only three eyes had isolated holes that were not adjacent to a vessel. The holes tended to be in the regions that are thickest in healthy controls and were associated with arcuate defects in patients. Holes were not seen in the center of the temporal disc region. They were more common in the superior (25 eyes) than in the inferior (15 eyes) disc. Of the 30 eyes with holes with reliable visual fields, seven were glaucoma suspect eyes with normal visual fields. The holes in the RNFL seen in patients with GON were probably due to a local loss of RNFL fibers and can occur in the eyes of glaucoma suspects with normal visual fields.
Lehner, Rea; Balsters, Joshua H.; Bürgler, Alexandra; Hare, Todd A.; Wenderoth, Nicole
2017-01-01
Obese individuals have been shown to exhibit abnormal sensitivity to rewards and reward-predicting cues as for example food-associated cues frequently used in advertisements. It has also been shown that food-associated cues can increase goal-directed behavior but it is currently unknown, whether this effect differs between normal-weight, overweight, and obese individuals. Here, we investigate this question by using a Pavlovian-to-instrumental transfer (PIT) task in normal-weight (N = 20), overweight (N = 17), and obese (N = 17) individuals. Furthermore, we applied eye tracking during Pavlovian conditioning to measure the participants’ conditioned response as a proxy of the incentive salience of the predicted reward. Our results show that the goal-directed behavior of overweight individuals was more strongly influenced by food-predicting cues (i.e., stronger PIT effect) than that of normal-weight and obese individuals (p < 0.001). The weight groups were matched for age, gender, education, and parental education. Eye movements during Pavlovian conditioning also differed between weight categories (p < 0.05) and were used to categorize individuals based on their fixation style into “high eye index” versus “low eye index” as well. Our main finding was that the fixation style exhibited a complex interaction with the weight category. Furthermore, we found that normal-weight individuals of the group “high eye index” had higher body mass index within the healthy range than individuals of the group “low eye index” (p < 0.001), but this relationship was not found within in the overweight or obese groups (p > 0.646). Our findings are largely consistent with the incentive sensitization theory predicting that overweight individuals are more susceptible to food-related cues than normal-weight controls. However, this hypersensitivity might be reduced in obese individuals, possibly due to habitual/compulsive overeating or differences in reward valuation. PMID:29180968
Lehner, Rea; Balsters, Joshua H; Bürgler, Alexandra; Hare, Todd A; Wenderoth, Nicole
2017-01-01
Obese individuals have been shown to exhibit abnormal sensitivity to rewards and reward-predicting cues as for example food-associated cues frequently used in advertisements. It has also been shown that food-associated cues can increase goal-directed behavior but it is currently unknown, whether this effect differs between normal-weight, overweight, and obese individuals. Here, we investigate this question by using a Pavlovian-to-instrumental transfer (PIT) task in normal-weight ( N = 20), overweight ( N = 17), and obese ( N = 17) individuals. Furthermore, we applied eye tracking during Pavlovian conditioning to measure the participants' conditioned response as a proxy of the incentive salience of the predicted reward. Our results show that the goal-directed behavior of overweight individuals was more strongly influenced by food-predicting cues (i.e., stronger PIT effect) than that of normal-weight and obese individuals ( p < 0.001). The weight groups were matched for age, gender, education, and parental education. Eye movements during Pavlovian conditioning also differed between weight categories ( p < 0.05) and were used to categorize individuals based on their fixation style into "high eye index" versus "low eye index" as well. Our main finding was that the fixation style exhibited a complex interaction with the weight category. Furthermore, we found that normal-weight individuals of the group "high eye index" had higher body mass index within the healthy range than individuals of the group "low eye index" ( p < 0.001), but this relationship was not found within in the overweight or obese groups ( p > 0.646). Our findings are largely consistent with the incentive sensitization theory predicting that overweight individuals are more susceptible to food-related cues than normal-weight controls. However, this hypersensitivity might be reduced in obese individuals, possibly due to habitual/compulsive overeating or differences in reward valuation.
Amblyopia, or "lazy eye," is the most common cause of visual impairment in children. It happens when an eye fails to work properly with the brain. The eye may look normal, but the brain favors the ...
The Role of Eye Movement Driven Attention in Functional Strabismic Amblyopia
2015-01-01
Strabismic amblyopia “blunt vision” is a developmental anomaly that affects binocular vision and results in lowered visual acuity. Strabismus is a term for a misalignment of the visual axes and is usually characterized by impaired ability of the strabismic eye to take up fixation. Such impaired fixation is usually a function of the temporally and spatially impaired binocular eye movements that normally underlie binocular shifts in visual attention. In this review, we discuss how abnormal eye movement function in children with misaligned eyes influences the development of normal binocular visual attention and results in deficits in visual function such as depth perception. We also discuss how eye movement function deficits in adult amblyopia patients can also lead to other abnormalities in visual perception. Finally, we examine how the nonamblyopic eye of an amblyope is also affected in strabismic amblyopia. PMID:25838941
Optical coherence tomography study of retinal changes in normal aging and after ischemia.
Shariati, Mohammad Ali; Park, Joyce Ho; Liao, Yaping Joyce
2015-05-01
Age-related thinning of the retinal ganglion cell axons in the nerve fiber layer has been measured in humans using optical coherence tomography (OCT). In this study, we used OCT to measure inner retinal changes in 3-month-, 1-year-, and 2-year-old mice and after experimental anterior ischemic optic neuropathy (AION). We used OCT to quantify retinal thickness in over 200 eyes at different ages before and after a photochemical thrombosis model of AION. The scans were manually or automatically segmented. In normal aging, there was 1.3-μm thinning of the ganglion cell complex (GCC) between 3 months and 1 year (P < 0.0001) and no further thinning at 2 years. In studying age-related inner retinal changes, measurement of the GCC (circular scan) was superior to that of the total retinal thickness (posterior pole scan) despite the need for manual segmentation because it was not contaminated by outer retinal changes. Three weeks after AION, there was 8.9-μm thinning of the GCC (circular scan; P < 0.0001), 50-μm thinning of the optic disc (posterior pole scan; P < 0.0001), and 17-μm thinning of the retina (posterior pole scan; P < 0.0001) in the 3-month-old group. Changes in the older eyes after AION were similar to those of the 3-month-old group. Optical coherence tomography imaging of a large number of eyes showed that, like humans, mice exhibited small, age-related inner retinal thinning. Measurement of the GCC was superior to total retinal thickness in quantifying age-related changes, and both circular and posterior pole scans were useful to track short-term changes after AION.
Cater, Kathleen C; Harbell, John W
2008-01-01
The bovine corneal opacity and permeability (BCOP) assay can be used to predict relative eye irritation potential of surfactant-based personal care formulations relative to a corporate benchmark. The human eye sting test is typically used to evaluate product claims of no tears/no stinging for children's bath products. A preliminary investigation was conducted to test a hypothesis that the BCOP assay could be used as a prediction model for relative ranking of human eye irritation responses under conditions of a standard human eye sting test to surfactant-based formulations. BCOP assays and human eye sting tests were conducted on 4 commercial and 1 prototype body wash (BW) developed specifically for children or as mild bath products. In the human eye sting test, 10 mul of a 10% dosing solution is instilled into one eye of each panelist (n = 20), and the contralateral eye is dosed with sterile water as a control. Bulbar conjunctival erythema responses of each eye are graded at 30 seconds by an ophthalmologist. The BCOP assay permeability values (optical density at 490 nm [OD(490)]) for the 5 BWs ranged from 0.438 to 1.252 (i.e., least to most irritating). By comparison, the number of panelists exhibiting erythema responses (mild to moderately pink) ranged from 3 of 20 panelists for the least irritating BW to 10 of 20 panelists for the most irritating BW tested. The relative ranking of eye irritation potential of the 5 BWs in the BCOP assay compares favorably with the relative ranking of the BWs in the human eye sting test. Based on these findings, the permeability endpoint of the BCOP assay, as described for surfactant-based formulations, showed promise as a prediction model for relative ranking of conjunctival erythema responses in the human eye. Consequently, screening of prototype formulations in the BCOP assay would allow for formula optimization of mild bath products prior to investment in a human eye sting test.
The Relationship Between Fusion, Suppression, and Diplopia in Normal and Amblyopic Vision.
Spiegel, Daniel P; Baldwin, Alex S; Hess, Robert F
2016-10-01
Single vision occurs through a combination of fusion and suppression. When neither mechanism takes place, we experience diplopia. Under normal viewing conditions, the perceptual state depends on the spatial scale and interocular disparity. The purpose of this study was to examine the three perceptual states in human participants with normal and amblyopic vision. Participants viewed two dichoptically separated horizontal blurred edges with an opposite tilt (2.35°) and indicated their binocular percept: "one flat edge," "one tilted edge," or "two edges." The edges varied with scale (fine 4 min arc and coarse 32 min arc), disparity, and interocular contrast. We investigated how the binocular interactions vary in amblyopic (visual acuity [VA] > 0.2 logMAR, n = 4) and normal vision (VA ≤ 0 logMAR, n = 4) under interocular variations in stimulus contrast and luminance. In amblyopia, despite the established sensory dominance of the fellow eye, fusion prevails at the coarse scale and small disparities (75%). We also show that increasing the relative contrast to the amblyopic eye enhances the probability of fusion at the fine scale (from 18% to 38%), and leads to a reversal of the sensory dominance at coarse scale. In normal vision we found that interocular luminance imbalances disturbed binocular combination only at the fine scale in a way similar to that seen in amblyopia. Our results build upon the growing evidence that the amblyopic visual system is binocular and further show that the suppressive mechanisms rendering the amblyopic system functionally monocular are scale dependent.
Recognition and localization of relevant human behavior in videos
NASA Astrophysics Data System (ADS)
Bouma, Henri; Burghouts, Gertjan; de Penning, Leo; Hanckmann, Patrick; ten Hove, Johan-Martijn; Korzec, Sanne; Kruithof, Maarten; Landsmeer, Sander; van Leeuwen, Coen; van den Broek, Sebastiaan; Halma, Arvid; den Hollander, Richard; Schutte, Klamer
2013-06-01
Ground surveillance is normally performed by human assets, since it requires visual intelligence. However, especially for military operations, this can be dangerous and is very resource intensive. Therefore, unmanned autonomous visualintelligence systems are desired. In this paper, we present an improved system that can recognize actions of a human and interactions between multiple humans. Central to the new system is our agent-based architecture. The system is trained on thousands of videos and evaluated on realistic persistent surveillance data in the DARPA Mind's Eye program, with hours of videos of challenging scenes. The results show that our system is able to track the people, detect and localize events, and discriminate between different behaviors, and it performs 3.4 times better than our previous system.
Effects of Device on Video Head Impulse Test (vHIT) Gain.
Janky, Kristen L; Patterson, Jessie N; Shepard, Neil T; Thomas, Megan L A; Honaker, Julie A
2017-10-01
Numerous video head impulse test (vHIT) devices are available commercially; however, gain is not calculated uniformly. An evaluation of these devices/algorithms in healthy controls and patients with vestibular loss is necessary for comparing and synthesizing work that utilizes different devices and gain calculations. Using three commercially available vHIT devices/algorithms, the purpose of the present study was to compare: (1) horizontal canal vHIT gain among devices/algorithms in normal control subjects; (2) the effects of age on vHIT gain for each device/algorithm in normal control subjects; and (3) the clinical performance of horizontal canal vHIT gain between devices/algorithms for differentiating normal versus abnormal vestibular function. Prospective. Sixty-one normal control adult subjects (range 20-78) and eleven adults with unilateral or bilateral vestibular loss (range 32-79). vHIT was administered using three different devices/algorithms, randomized in order, for each subject on the same day: (1) Impulse (Otometrics, Schaumberg, IL; monocular eye recording, right eye only; using area under the curve gain), (2) EyeSeeCam (Interacoustics, Denmark; monocular eye recording, left eye only; using instantaneous gain), and (3) VisualEyes (MicroMedical, Chatham, IL, binocular eye recording; using position gain). There was a significant mean difference in vHIT gain among devices/algorithms for both the normal control and vestibular loss groups. vHIT gain was significantly larger in the ipsilateral direction of the eye used to measure gain; however, in spite of the significant mean differences in vHIT gain among devices/algorithms and the significant directional bias, classification of "normal" versus "abnormal" gain is consistent across all compared devices/algorithms, with the exception of instantaneous gain at 40 msec. There was not an effect of age on vHIT gain up to 78 years regardless of the device/algorithm. These findings support that vHIT gain is significantly different between devices/algorithms, suggesting that care should be taken when making direct comparisons of absolute gain values between devices/algorithms. American Academy of Audiology
Normative database of donor keratographic readings in an eye-bank setting.
Lewis, Jennifer R; Bogucki, Jennifer M; Mahmoud, Ashraf M; Lembach, Richard G; Roberts, Cynthia J
2010-04-01
To generate a normative donor topographic database from rasterstereography images of whole globes acquired in an eye-bank setting with minimal manipulation or handling. Eye-bank laboratory. In a retrospective study, rasterstereography topographic images that had been prospectively collected in duplicate of donor eyes received by the Central Ohio Lions Eye Bank between 1997 and 1999 were analyzed. Best-fit sphere (BFS) and simulated keratometry (K) values were extracted. These values were recalculated after application of custom software to correct any tilt of the mapped surfaces relative to the image plane. The mean value variances between right eyes and left eyes, between consecutive scans, and after untilting were analyzed by repeated-measures analysis of variance and t tests (P
Effect of mistletoe combined with carboxymethyl cellulose on dry eye in postmenopausal women
Jiang, Nan; Ye, Lin-Hong; Ye, Lei; Yu, Jing; Yang, Qi-Chen; Yuan, Qing; Zhu, Pei-Wen; Shao, Yi
2017-01-01
AIM To investigate the protective effect of mistletoe combined with carboxymethyl cellulose eye drops on dry eye in postmenopausal women. METHODS Sixty postmenopause female patients diagnosed of dry eye were assigned randomly to mistletoe combined with carboxymethyl cellulose eye drops treatment group (n=30) and control group treated with normal saline eye drops (n=30). The subjective symptoms of ocular surface, Ocular Surface Disease Index (OSDI), tear film function tests, tear protein and corneal morphology by confocal scanning microscopy were analyzed before treatment and at 1, 2, 4 and 8wk after treatment respectively. To ensure the safety of the trial, all patients were examined with systolic pressure, diastolic pressure, glutamic-pyruvic transaminase, glutamic oxaloacetic transaminase, urine creatinine, and blood urea nitrogen at 8wk after treatment. RESULTS There were no obvious differences between two groups before the treatment (P>0.05). In two months after the treatment, the symptoms of ocular surface, OSDI, tear protein, and tear film function were only slightly changed in normal saline eye drops group. However, all indices were improved after the treatment of mistletoe combined with carboxymethyl cellulose eye drops group (P<0.05). In addition, the average amount of corneal epithelium basal cells and inflammatory cells of mistletoe treated group were 3174±379 and 38±25 cells/mm2, significantly decreased as compared to the control group with 4309±612 and 158± 61 cells/mm2, respectively. In the control group, although nerves still maintained straight under corneal epithelium, the number of nerves were significantly decreased, as compared with normal female. In the mistletoe treated group, the number of nerves was only slightly reduced, compared with normal female. CONCLUSION Mistletoe combined with carboxymethyl cellulose eye drops can alleviate the symptoms and signs of dry eye symptoms. PMID:29181309
Linkage mapping of the primary disease locus for collie eye anomaly.
Lowe, Jennifer K; Kukekova, Anna V; Kirkness, Ewen F; Langlois, Mariela C; Aguirre, Gustavo D; Acland, Gregory M; Ostrander, Elaine A
2003-07-01
Collie eye anomaly (cea) is a hereditary ocular disorder affecting development of the choroid and sclera segregating in several breeds of dog, including rough, smooth, and Border collies and Australian shepherds. The disease is reminiscent of the choroidal hypoplasia phenotype observed in humans in conjunction with craniofacial or renal abnormalities. In dogs, however, the clinical phenotype can vary significantly; many dogs exhibit no obvious clinical consequences and retain apparently normal vision throughout life, while severely affected animals develop secondary retinal detachment, intraocular hemorrhage, and blindness. We report genetic studies establishing that the primary cea phenotype, choroidal hypoplasia, segregates as an autosomal recessive trait with nearly 100% penetrance. We further report linkage mapping of the primary cea locus to a 3.9-cM region of canine chromosome 37 (LOD = 22.17 at theta = 0.076), in a region corresponding to human chromosome 2q35. These results suggest the presence of a developmental regulatory gene important in ocular embryogenesis, with potential implications for other disorders of ocular vascularization.
Elgin, Ufuk; Cankaya, Bülent; Simsek, Tulay; Batman, Aygen
2010-01-01
To compare the optic disc topography parameters of children with juvenile diabetes mellitus and normal children using the Heidelberg Retinal Tomograph (HRT III) (Heidelberg Engineering, Heidelberg, Germany). The topographic optic disc parameters (cup volume, cup area, rim volume, rim area, disc area, mean cup-to-disc ratio, and mean cup depth) of 28 non-glaucomatous eyes of 28 children with type 1 diabetes mellitus and 28 eyes of 28 age-matched healthy children were compared using the nonparametric Mann-Whitney U test. No statistically significant differences were found between cup volume (P = .782), cup area (P = .878), rim volume (P = .853), disc area (P = .452), mean cup-to-disc ratio (P = .852), and mean cup depth (P = .711) of eyes of cases with diabetes mellitus and normal subjects. This result suggests that non-glaucomatous eyes of children with type 1 diabetes mellitus and healthy subjects have similar topographic optic disc characteristics. Copyright 2010, SLACK Incorporated.
NASA Technical Reports Server (NTRS)
Das, V. E.; Thomas, C. W.; Zivotofsky, A. Z.; Leigh, R. J.
1996-01-01
Video-based eye-tracking systems are especially suited to studying eye movements during naturally occurring activities such as locomotion, but eye velocity records suffer from broad band noise that is not amenable to conventional filtering methods. We evaluated the effectiveness of combined median and moving-average filters by comparing prefiltered and postfiltered records made synchronously with a video eye-tracker and the magnetic search coil technique, which is relatively noise free. Root-mean-square noise was reduced by half, without distorting the eye velocity signal. To illustrate the practical use of this technique, we studied normal subjects and patients with deficient labyrinthine function and compared their ability to hold gaze on a visual target that moved with their heads (cancellation of the vestibulo-ocular reflex). Patients and normal subjects performed similarly during active head rotation but, during locomotion, patients held their eyes more steadily on the visual target than did subjects.
Determination of the toxicity of intravitreal minocycline in rabbit eyes.
Falavarjani, Khalil Ghasemi; Pourhabibi, Arash; Aghdam, Kaveh Abri; Hosseini, Seyed Bagher; Modarres, Mehdi; Pazouki, Abdolreza; Khanamiri, Hossein Nazari
2016-09-01
To evaluate the retinal toxicity of intravitreal minocycline in rabbit eyes. Intravitreal injection of minocycline with concentrations of 1000, 500, 250, 125 and 62.5 μg in 0.1 ml was performed in 10 New Zealand albino rabbits. Each concentration was injected into two rabbit eyes. For each dose, normal saline was injected in one contralateral eye and the other fellow eye remained non-injected. Electrophysiologic testing was performed before and 4 weeks after injections. The eyes were enucleated 4 weeks after injections and examined using light microscopy. The clinical examination was unremarkable after injections. Electroretinography recordings were significantly affected at all doses in at least one of the a- or b-waves of photopic or scotopic responses. Histopathologic examination revealed marked atrophy and loss of integrity in all retinal layers in all minocycline injected eyes. Contralateral eyes were normal. In our study, intravitreal minocycline was toxic to the retina in albino rabbits even at a concentration of 62.5 µg/0.1 ml.
Isolated eyeball metastasis of non-seminomatous germ cell testicular tumor.
Bojanić, Nebojsa; Nale, Djordje; Mićić, Sava; Janicić, Aleksandar; Vuksanović, Aleksandar; Vuković, Ivan
2011-11-01
Testicular tumors most frequently metastasize to regional lymph nodes. Non-seminomatous tumor metastasis of testicle (NSGCTT) to the eyeball is rare. We presented a 24-year old man, referred to the ophthalmologist due to acute pain and abrupt loss of sight in the left eye accompanied by its enlargement. Orbital and endocranial computerized tomography (CT) was carried out, indicating the tumor in the left eye. His previous medical history provided the information that the right testicle was painlessly enlarged for 8 months. Ultrasonography showed a completely tumorously altered testis. Abdominal and chest CT failed to reveal any secondary deposits in visceral organs and lymph glands. Tumor markers (AFP - alpha-fetoproteins, beta hCG - human choronic gonadotropin beta) were elevated. Right radical orchiactomy was performed (showed NSGCTT), followed by polychemotherapy with cisplatinum 100 mg/m2, etoposide 120 mg/m2, bleomycin 15 mg/m2 (PEB x 4), resulting in normalization of tumor marker values and significant regression of the left eyeball. Next, the left eye enucleation and ocular prosthesis implantation was carried out. Pathohistological evaluation indicated fibrosis and necrosis only. In a 5-year follow-up period, the patient was free of recurrence. Isolated hematogenous metastasis of the NSGCTT to the eye is rare. In our case, the left eye was the only metastatic localization. After chemotherapy and eye enucleation the patient was in a 4-year follow-up period free of the recurrence.
An Epha4/Sipa1l3/Wnt pathway regulates eye development and lens maturation.
Rothe, Melanie; Kanwal, Noreen; Dietmann, Petra; Seigfried, Franziska A; Hempel, Annemarie; Schütz, Desiree; Reim, Dominik; Engels, Rebecca; Linnemann, Alexander; Schmeisser, Michael J; Bockmann, Juergen; Kühl, Michael; Boeckers, Tobias M; Kühl, Susanne J
2017-01-15
The signal-induced proliferation-associated family of proteins comprises four members, SIPA1 and SIPA1L1-3. Mutations of the human SIPA1L3 gene result in congenital cataracts. In Xenopus, loss of Sipa1l3 function led to a severe eye phenotype that was distinguished by smaller eyes and lenses including lens fiber cell maturation defects. We found a direct interaction between Sipa1l3 and Epha4, building a functional platform for proper ocular development. Epha4 deficiency phenocopied loss of Sipa1l3 and rescue experiments demonstrated that Epha4 acts upstream of Sipa1l3 during eye development, with both Sipa1l3 and Epha4 required for early eye specification. The ocular phenotype, upon loss of either Epha4 or Sipa1l3, was partially mediated by rax We demonstrate that canonical Wnt signaling is inhibited downstream of Epha4 and Sipa1l3 during normal eye development. Depletion of either Sipa1l3 or Epha4 resulted in an upregulation of axin2 expression, a direct Wnt/β-catenin target gene. In line with this, Sipa1l3 or Epha4 depletion could be rescued by blocking Wnt/β-catenin or activating non-canonical Wnt signaling. We therefore conclude that this pathomechanism prevents proper eye development and maturation of lens fiber cells, resulting in congenital cataracts. © 2017. Published by The Company of Biologists Ltd.
Fortune, Brad; Demirel, Shaban; Zhang, Xian; Hood, Donald C; Patterson, Emily; Jamil, Annisa; Mansberger, Steven L; Cioffi, George A; Johnson, Chris A
2007-03-01
To compare the diagnostic performance of multifocal visual evoked potential (mfVEP) and standard automated perimetry (SAP), in eyes with high-risk ocular hypertension or early glaucoma. Both eyes of 185 individuals with high-risk ocular hypertension or early glaucoma were evaluated. Subjects ranged in age from 37 to 87 (mean +/- SD: 61 +/- 11 years). Pattern-reversal mfVEPs were obtained by using VERIS (Electro-Diagnostic Imaging, San Mateo, CA) with a four-electrode array and were analyzed with custom software. SAP visual fields (SITA-standard; Carl Zeiss Meditec, Inc., Dublin, CA) were obtained within 22.3 +/- 27.0 days of the mfVEP. Stereo disc photographs and Heidelberg Retina Tomograph (HRT) images were obtained during one visit, which was within 24.8 +/- 50.4 days of the mfVEP and 33.1 +/- 62.9 days of the SAP visual field. Abnormalities on the mfVEP were defined by using a variety of cluster criteria: SAP with pattern standard deviation (PSD) P = 0.05 or glaucoma hemifield test (GHT) outside normal limits, according to OHTS criteria (SAP-OHTS). In separate analyses cluster criteria were used to determine SAP abnormalities. Disc photographs were graded as either glaucomatous optic neuropathy (GON) or normal by two independent masked experts, and disagreements were adjudicated by a third masked expert. The overall Moorfields regression analysis (MRA) result from the HRT was used as a separate diagnostic classification. All eyes classified as "borderline" by the MRA were assigned to the normal category (i.e., "within normal limits"). Sensitivity for mfVEP or SAP was defined as the percentage of GON eyes that had an abnormality on the functional test. Specificity for mfVEP or SAP was defined as the percentage of eyes with normal optic disc structure that had normal functional test results. Disc photographs from 50% of eyes were graded GON. Both eyes were graded GON in 71 (38%) of the 185 subjects. Exactly half as many eyes were abnormal by HRT MRA. The average SAP mean deviation (MD) was +0.3 +/- 2.1 dB; average PSD was 2.3 +/- 1.9 dB. By OHTS criteria, 83 (22%) of the 370 eyes had an abnormal SAP. Depending on the cluster criterion used, the proportion of eyes with an abnormal SAP ranged from 8% to 26% and with an abnormal mfVEP, from 14% to 45%. A criterion with an estimated specificity in normal subjects of 91% resulted in 102 (28%) eyes with an abnormal mfVEP. For criteria with estimated specificities of 95% and 99%, respectively, 88 (24%) eyes and 52 (14%) eyes had an abnormal mfVEP. Agreement between SAP and mfVEP ranged from 75% to 81%. The sensitivity of SAP-OHTS to detect GON (using the disc photograph as diagnostic standard) was 29%, whereas specificity was 84%. Sensitivity of the mfVEP to detect GON, for cluster criteria with disc structure specificity between 84% and 87%, ranged from 28% to 32%. When the HRT MRA was used as the diagnostic standard, sensitivities of both functional tests to detect GON increased to 42%. The diagnostic performance of mfVEP was similar to that of SAP. However, the two modalities agreed in only approximately 80% of eyes, suggesting that they may detect slightly different functional deficits.
... this page: //medlineplus.gov/ency/presentations/100206.htm Lasik eye surgery - series—Normal anatomy To use the ... A.M. Editorial team. Related MedlinePlus Health Topics Laser Eye Surgery A.D.A.M., Inc. is accredited by ...
Menghini, Moreno; Lujan, Brandon J; Zayit-Soudry, Shiri; Syed, Reema; Porco, Travis C; Bayabo, Kristine; Carroll, Joseph; Roorda, Austin; Duncan, Jacque L
2014-12-16
We studied the correlation between outer nuclear layer (ONL) thickness and cone density in normal eyes and eyes with retinitis pigmentosa (RP). Spectral-domain optical coherence tomography (SD-OCT) scans were acquired using a displaced pupil entry position of the scanning beam to distinguish Henle's fiber layer from the ONL in 20 normal eyes (10 subjects) and 12 eyes with RP (7 patients). Cone photoreceptors were imaged using adaptive optics scanning laser ophthalmoscopy. The ONL thickness and cone density were measured at 0.5° intervals along the horizontal meridian through the fovea nasally and temporally. The ONL thickness and cone density were correlated using Spearman's rank correlation coefficient r. Cone densities averaged over the central 6° were lower in eyes with RP than normal, but showed high variability in both groups. The ONL thickness and cone density were significantly correlated when all retinal eccentricities were combined (r = 0.74); the correlation for regions within 0.5° to 1.5° eccentricity was stronger (r = 0.67) than between 1.5° and 3.0° eccentricity (r = 0.23). Although cone densities were lower between 0.5° and 1.5° in eyes with RP, ONL thickness measures at identical retinal locations were similar in the two groups (P = 0.31), and interindividual variation was high for ONL and cone density measures. Although ONL thickness and retinal eccentricity were important predictors of cone density, eccentricity was over 3 times more important. The ONL thickness and cone density were correlated in normal eyes and eyes with RP, but both were strongly correlated with retinal eccentricity, precluding estimation of cone density from ONL thickness. (ClinicalTrials.gov number, NCT00254605.). Copyright 2015 The Association for Research in Vision and Ophthalmology, Inc.
Menghini, Moreno; Lujan, Brandon J.; Zayit-Soudry, Shiri; Syed, Reema; Porco, Travis C.; Bayabo, Kristine; Carroll, Joseph; Roorda, Austin; Duncan, Jacque L.
2015-01-01
Purpose. We studied the correlation between outer nuclear layer (ONL) thickness and cone density in normal eyes and eyes with retinitis pigmentosa (RP). Methods. Spectral-domain optical coherence tomography (SD-OCT) scans were acquired using a displaced pupil entry position of the scanning beam to distinguish Henle's fiber layer from the ONL in 20 normal eyes (10 subjects) and 12 eyes with RP (7 patients). Cone photoreceptors were imaged using adaptive optics scanning laser ophthalmoscopy. The ONL thickness and cone density were measured at 0.5° intervals along the horizontal meridian through the fovea nasally and temporally. The ONL thickness and cone density were correlated using Spearman's rank correlation coefficient r. Results. Cone densities averaged over the central 6° were lower in eyes with RP than normal, but showed high variability in both groups. The ONL thickness and cone density were significantly correlated when all retinal eccentricities were combined (r = 0.74); the correlation for regions within 0.5° to 1.5° eccentricity was stronger (r = 0.67) than between 1.5° and 3.0° eccentricity (r = 0.23). Although cone densities were lower between 0.5° and 1.5° in eyes with RP, ONL thickness measures at identical retinal locations were similar in the two groups (P = 0.31), and interindividual variation was high for ONL and cone density measures. Although ONL thickness and retinal eccentricity were important predictors of cone density, eccentricity was over 3 times more important. Conclusions. The ONL thickness and cone density were correlated in normal eyes and eyes with RP, but both were strongly correlated with retinal eccentricity, precluding estimation of cone density from ONL thickness. (ClinicalTrials.gov number, NCT00254605.) PMID:25515570
Role of percent tissue altered on ectasia after LASIK in eyes with suspicious topography.
Santhiago, Marcony R; Smadja, David; Wilson, Steven E; Krueger, Ronald R; Monteiro, Mario L R; Randleman, J Bradley
2015-04-01
To investigate the association of the percent tissue altered (PTA) with the occurrence of ectasia after LASIK in eyes with suspicious preoperative corneal topography. This retrospective comparative case-control study compared associations of reported ectasia risk factors in 129 eyes, including 57 eyes with suspicious preoperative Placido-based corneal topography that developed ectasia after LASIK (suspect ectasia group), 32 eyes with suspicious topography that remained stable for at least 3 years after LASIK (suspect control group), and 30 eyes that developed ectasia with bilateral normal topography (normal topography ectasia group). Groups were subdivided based on topographic asymmetry into high- or low-suspect groups. The PTA, preoperative central corneal thickness (CCT), residual stromal bed (RSB), and age (years) were evaluated in univariate and multivariate analyses. Average PTA values for normal topography ectasia (45), low-suspect ectasia (39), high-suspect ectasia (36), low-suspect control (32), and high-suspect control (29) were significantly different from one another in all comparisons (P < .003) except high- and low-suspect ectasia groups (P = .033), and presented the highest discriminative capability of all variables evaluated. Age was only significantly different between the high-suspect ectasia and normal topography ectasia groups, and CCT was not significantly different between any groups. Stepwise logistic regression revealed the PTA as the most significant independent variable (P < .0001), with RSB the next most significant parameter. There remains a significant correlation between PTA values and ectasia risk after LASIK, even in eyes with suspicious corneal topography. Less tissue alteration, or a lower PTA value, was necessary to induce ectasia in eyes with more remarkable signs of topographic abnormality, and PTA provided better discriminative capabilities than RSB for all study populations. Copyright 2015, SLACK Incorporated.
Gene expression signatures in tree shrew choroid in response to three myopiagenic conditions
He, Li; Frost, Michael R.; Siegwart, John T.; Norton, Thomas T.
2014-01-01
We examined gene expression in tree shrew choroid in response to three different myopiagenic conditions: minus lens (ML) wear, form deprivation (FD), and continuous darkness (DK). Four groups of tree shrews (n = 7 per group) were used. Starting 24 days after normal eye opening (days of visual experience [DVE]), the ML group wore a monocular −5 D lens for 2 days. The FD group wore a monocular translucent diffuser for 2 days. The DK group experienced continuous darkness binocularly for 11 days, starting at 17 DVE. An age-matched normal group was examined at 26 DVE. Quantitative PCR was used to measure the relative (treated eye vs. control eye) differences in mRNA levels in the choroid for 77 candidate genes. Small myopic changes were observed in the treated eyes (relative to the control eyes) of the ML group (−1.0 ± 0.2 D; mean ± SEM) and FD group (−1.9 ± 0.2 D). A larger myopia developed in the DK group (−4.4 ± 1.0 D) relative to Normal eyes (both groups, mean of right and left eyes). In the ML group, 28 genes showed significant differential mRNA expression; eighteen were down-regulated. A very similar pattern occurred in the FD group; twenty-seven of the same genes were similarly regulated, along with five additional genes. Fewer expression differences in the DK group were significant compared to normal or the control eyes of the ML and FD groups, but the pattern was similar to that of the ML and FD differential expression patterns. These data suggest that, at the level of the choroid, the gene expression signatures produced by “GO” emmetropization signals are highly similar despite the different visual conditions. PMID:25072854
Flügel-Koch, Cassandra M.; Tektas, Ozan Y.; Kaufman, Paul L.; Paulsen, Friedrich P.; Lütjen-Drecoll, Elke
2014-01-01
Purpose. To analyze the peripheral fixation of the iris dilator muscle in normal eyes and in eyes with pigmentary glaucoma (PG). Methods. Using 63 control eyes (age 18 months–99 years), the peripheral iris dilator was investigated by light microscopy, immunohistochemistry, and electron microscopy. Development was studied using 18 differently aged fetal eyes stained immunohistochemically against α-smooth muscle (SM) actin. The peripheral iris dilator muscle in PG was analyzed using semithin and ultrathin sections of six glutaraldehyde-fixed eyes from three donors aged 38, 62, and 74 years. Results. In normal eyes, the peripheral end of the iris dilator muscle is arranged in a sphincter-like manner. Arcade-shaped tendinous connections associated with myofibroblasts (iridial strands) anchor the iris dilator within the elastic–fibromuscular ciliary meshwork that also serves as fixation area for the elastic tendons of the inner ciliary muscle portions. The iridial strands are innervated and can adapt their length during accommodation. The PG eyes show incomplete circular bundles and iridial strands that are mainly anchored to the iris stroma and the flexible uveal parts of the trabecular meshwork. Conclusions. The normal anchorage of the peripheral iris dilator and its presumably neuronally regulated length adaptation stabilize the peripheral iris during accommodation. Insufficient fixation in PG could promote posterior bowing of the iris with rubbing against the zonular fibers and pigment liberation from the iris pigmented epithelium. PMID:24938519
Influence of the corneal optical zone on the point-spread function of the human eye
NASA Astrophysics Data System (ADS)
Rol, Pascal O.; Parel, Jean-Marie A.
1992-08-01
In refractive surgery, a number of surgical techniques have been developed to correct ametropia (refractive defaults) of the eye by changing the exterior shape of the cornea. Because the air-cornea interface makes up for about two thirds of the refractive power of the eye, a refractive correction can be obtained by a suitable reshaping of the cornea. Postoperatively, it is usually observed that the corneal region consists of two or more zones which are characterized by different optical parameters exhibiting in particular different focal distances. Under normal circumstances, only the central area of the cornea is involved in the formation of the retinal image. However, if part of the light entering the eye through peripheral portions of the cornea with refractive properties different from the central area can pass the pupil, an out-of-focus `ghost' image may be overlaid on the retina causing a blur. In such a case the resolution, and the contrast performance of the eye which is expected from a successful operation, may be reduced. This study is an attempt to quantify the vision blur as a function of the diameter of the central zone, i.e., the optical zone which is of importance for vision.
Optic nerve head axonal transport in rabbits with hereditary glaucoma.
Bunt-Milam, A H; Dennis, M B; Bensinger, R E
1987-04-01
Rabbits with hereditary glaucoma develop ocular changes that resemble human congenital glaucoma and buphthalmia. The inheritance is autosomal recessive (bu). Previous research was performed primarily on albino bu/bu rabbits that were unhealthy and bred poorly. We have bred pigmented bu/bu rabbits to determine if this would improve hardiness and provide a better model for the disease in humans. First-generation offspring from matings of bu/bu albino with bu/bu pigmented rabbits were all affected, indicating that the bu gene is found at the same locus in both strains. The pigmented bu/bu offspring had a high degree of mortality, as reported previously for albino bu/bu rabbits. Newborn bu/bu rabbits initially had normal intraocular pressure (IOP; 15-23 mmHg); after 1- to 3 months, the IOP increased to 26-48 mmHg. The eyes became buphthalmic and the IOP returned to normal or sub-normal levels after 6-10 months. Since the lamina cribrosa is absent or poorly formed in the rabbit optic nerve head (ONH), this model was used to test the role of mechanical factors in the etiology of ONH pathology caused by increased IOP. Orthograde axonal transport was evaluated in both eyes from eight normal and 24 bu/bu rabbits of different ages, using intravitreal injections of [3H]leucine to mark orthograde axonal transport, followed by light- and electron-microscopic radioautography of the ONHs and superior colliculi. Normal rabbits of all ages showed no blockage of axonal transport in the ONH. All optic axons from young bu/bu rabbits with normal IOP and most axons from older buphthalmic rabbits that previously had elevated IOP were normal morphologically. Small zones of transport blockage occurred in bu/bu eyes while IOP was elevated; most affected axons lay immediately adjacent to ONH connective tissue beams that radiate outward from the central retinal vessels to the optic-nerve sheath. Thus, the rabbit, which lacks a true lamina cribrosa, does not show marked blockage of axonal transport as occurs in the LS of the monkey and cat ONH when IOP is elevated acutely. This anatomic difference appears to be protective against axonal damage, since bu/bu rabbits with chronic IOP elevation did not show significant loss of optic axons. These results are consistent with the proposed 'mechanical' theory of ONH damage resulting from increased IOP. Electron-microscopic radioautography revealed that chronically elevated IOP in bu/bu rabbits, which caused small foci of blocked ONH axonal transport against ONH beams, also caused degeneration of a few optic nerve terminals in the superior colliculi as the disease progressed.(ABSTRACT TRUNCATED AT 400 WORDS)
Garg, Arun; Schwartz, Daniel; Stevens, Alexander A.
2007-01-01
What happens in vision related cortical areas when congenitally blind (CB) individuals orient attention to spatial locations? Previous neuroimaging of sighted individuals has found overlapping activation in a network of frontoparietal areas including frontal eye-fields (FEF), during both overt (with eye movement) and covert (without eye movement) shifts of spatial attention. Since voluntary eye movement planning seems irrelevant in CB, their FEF neurons should be recruited for alternative functions if their attentional role in sighted individuals is only due to eye movement planning. Recent neuroimaging of the blind has also reported activation in medial occipital areas, normally associated with visual processing, during a diverse set of non-visual tasks, but their response to attentional shifts remains poorly understood. Here, we used event-related fMRI to explore FEF and medial occipital areas in CB individuals and sighted controls with eyes closed (SC) performing a covert attention orienting task, using endogenous verbal cues and spatialized auditory targets. We found robust stimulus-locked FEF activation of all CB subjects, similar but stronger than in SC, suggesting that FEF plays a role in endogenous orienting of covert spatial attention even in individuals in whom voluntary eye movements are irrelevant. We also found robust activation in bilateral medial occipital cortex in CB but not in SC subjects. The response decreased below baseline following endogenous verbal cues but increased following auditory targets, suggesting that the medial occipital area in CB does not directly engage during cued orienting of attention but may be recruited for processing of spatialized auditory targets. PMID:17397882
Yasuda, Kanako; Miyazawa, Akiko; Shimura, Masahiko
2012-06-01
The aim of this study was to compare the anti-inflammatory efficacy of preservative-free and preserved 0.1% diclofenac eye drops for the management of postoperative inflammation after cataract surgery in patients with nonproliferative diabetic retinopathy and in normal controls. Forty-two diabetic patients and 50 normal control patients who underwent small-incision phacoemulsification cataract surgery bilaterally received topical preservative-free diclofenac in 1 eye and preserved diclofenac in the other eye. The corrected distance visual acuity (CDVA) as determined by a logarithm of the minimum angle of resolution (logMAR) chart, intraocular pressure (IOP), foveal thickness (FT) using optical coherence tomography (OCT), and the anterior chamber flare (ACF) score measured with a laser flare cell meter were monitored for 12 weeks after surgery. In the eyes with diabetic retinopathy, there were no significant differences in CDVA, IOP, FT, and ACF score between the right and left eyes at the initial exam. After cataract surgery, changes in CDVA, IOP, and FT were not influenced by the preservative in the diclofenac eye drops. In contrast, the ACF score in the eyes treated with preserved diclofenac showed slower recovery from postoperative inflammation than the eyes treated with preservative-free diclofenac. In the normal control eyes, similar but milder changes were observed in each of the clinical parameters. Because preservative suppressed the anti-inflammatory efficacy of topical diclofenac after cataract surgery, preservative-free diclofenac may have an improved safety profile during postoperative treatment, especially in patients with diabetic retinopathy.
Your Aging Eyes: How You See as Time Goes By
... Lengthen Life Keep an Eye on Your Eyes Building Social Bonds Coping with Caregiving Wise Choices Protect Your Vision Have a comprehensive eye exam each year after age 50. Stop smoking. Eat a diet rich in green, leafy vegetables and fish. Exercise. Maintain normal blood ...
Yonemura, D; Kawasaki, K; Madachi-Yamamoto, S
1984-05-30
The hyperosmolarity response of the standing potential was recorded in retinitis pigmentosa (20 eyes), central (pericentral) retinitis pigmentosa (4 eyes), pigmented paravenous retinochoroidal atrophy (2 eyes), fundus albipunctatus (8 eyes), and Stargardt's disease (or fundus flavimaculatus) (14 eyes). The light peak/dark trough ratio (the L/D ratio) and the Diamox response were also determined. The hyperosmolarity response was greatly suppressed (less than M-4SD; M and SD indicate respectively the mean and the standard deviation in normal control subjects) in all examined eyes with retinitis pigmentosa (20 eyes) including retinitis pigmentosa sine pigmento (8 eyes), central (pericentral) retinitis pigmentosa (4 eyes), and pigmented paravenous retinochoroidal atrophy (2 eyes). The L/D ratio was larger than 1.26 (M-2.5 SD) in the half of the eyes with the above-described diseases. The hyperosmolarity response was abnormal (less than M-2 SD) in 4 of 8 eyes with fundus albipunctatus. The L/D ratio was normal in all 8 eyes. The hyperosmolarity response was abnormal (less than M-2 SD) in all 14 eyes with Stargardt's disease or fundus flavimaculatus. The L/D ratio was abnormal in 5 of these 14 eyes. The hyperosmolarity response was more frequently abnormal than the L/D ratio in the chorioretinal dystrophies mentioned above, and hence is useful particularly for early diagnosis of these disorders.
Yonemura, D; Kawasaki, K; Madachi-Yamamoto, S
1984-05-01
The hyperosmolarity response of the standing potential was recorded in retinitis pigmentosa (20 eyes), central (pericentral) retinitis pigmentosa (4 eyes), pigmented paravenous retinochoroidal atrophy (2 eyes), fundus albipunctatus (8 eyes), and Stargardt's disease (or fundus flavimaculatus) (14 eyes). The light peak/dark trough ratio (the L/D ratio) and the Diamox response were also determined.The hyperosmolarity response was greatly suppressed (less than M-4SD; M and SD indicate respectively the mean and the standard deviation in normal control subjects) in all examined eyes with retinitis pigmentosa (20 eyes) including retinitis pigmentosa sine pigmento (8 eyes), central (pericentral) retinitis pigmentosa (4 eyes), and pigmented paravenous retinochoroidal atrophy (2 eyes). The L/D ratio was larger than 1.26 (M-2.5 SD) in the half of the eyes with the above-described diseases.The hyperosmolarity response was abnormal (less than M-2 SD) in 4 of 8 eyes with fundus albipunctatus. The L/D ratio was normal in all 8 eyes.The hyperosmolarity response was abnormal (less than M-2 SD) in all 14 eyes with Stargardt's disease or fundus flavimaculatus. The L/D ratio was abnormal in 5 of these 14 eyes.The hyperosmolarity response was more frequently abnormal than the L/D ratio in the chorioretinal dystrophies mentioned above, and hence is useful particularly for early diagnosis of these disorders.
The vestibulo-ocular reflex in fourth nerve palsy: deficits and adaptation.
Wong, Agnes M F; Sharpe, James A; Tweed, Douglas
2002-08-01
The effects of fourth nerve palsy on the vestibulo-ocular reflex (VOR) had not been systematically investigated. We used the magnetic scleral search coil technique to study the VOR in patients with unilateral fourth nerve palsy during sinusoidal head rotations in yaw, pitch and roll at different frequencies. In darkness, VOR gains are reduced during incyclotorsion, depression and abduction of the paretic eye, as anticipated from paresis of the superior oblique muscle. VOR gains during excyclotorsion, elevation and adduction of the paretic eye are also reduced, whereas gains in the non-paretic eye remain normal, indicating a selective adjustment of innervation to the paretic eye. In light, torsional visually enhanced VOR (VVOR) gains in the paretic eye remain reduced; however, visual input increases vertical and horizontal VVOR gains to normal in the paretic eye, without a conjugate increase in VVOR gains in the non-paretic eye, providing further evidence of selective adaptation in the paretic eye. Motions of the eyes after fourth nerve palsy exemplify monocular adaptation of the VOR, in response to peripheral neuromuscular deficits.
Exogenous orienting of attention depends upon the ability to execute eye movements.
Smith, Daniel T; Rorden, Chris; Jackson, Stephen R
2004-05-04
Shifts of attention can be made overtly by moving the eyes or covertly with attention being allocated to a region of space that does not correspond to the current direction of gaze. However, the precise relationship between eye movements and the covert orienting of attention remains controversial. The influential premotor theory proposes that the covert orienting of attention is produced by the programming of (unexecuted) eye movements and thus predicts a strong relationship between the ability to execute eye movements and the operation of spatial attention. Here, we demonstrate for the first time that impaired spatial attention is observed in an individual (AI) who is neurologically healthy but who cannot execute eye movements as a result of a congenital impairment in the elasticity of her eye muscles. This finding provides direct support for the role of the eye-movement system in the covert orienting of attention and suggests that whereas intact cortical structures may be necessary for normal attentional reflexes, they are not sufficient. The ability to move our eyes is essential for the development of normal patterns of spatial attention.
Ocular dominance in layer IV of the cat's visual cortex and the effects of monocular deprivation.
Shatz, C J; Stryker, M P
1978-01-01
1. The relation between the physiological pattern of ocular dominance and the anatomical distribution of geniculocortical afferents serving each eye was studied in layer IV of the primary visual cortex of normal and monocularly deprived cats. 2. One eye was injected with radioactive label. After allowing sufficient time for transeuronal transport, micro-electrode recordings were made, and the geniculocoritcal afferents serving the injected eye were located autoradiographically. 3. In layer IV of normal cats, cell were clustered according to eye preference, and fewer cells were binocularly driven than in other layers. Points of transition between groups of cells dominated by one eye and those dominated by the other were marked with electrolytic lesions. A good correspondence was found between the location of cells dominated by the injected eye and the patches of radioactively labelled geniculocortical afferents. 4. Following prolonged early monocular deprivation, the patches of geniculocortical afferents in layer IV serving the deprived eye were smaller, and those serving the non-deprived eye larger, than normal. Again there was a coincidence between the patches of radioactively labelled afferents and the location of cells dominated by the injected eye. 5. The deprived eye was found to dominate a substantial fraction (22%) of cortical cells in the fourth layer. In other cortical layers, only 7% of the cells were dominated by the deprived eye. 6. These findings suggest that the thalamocortical projection is physically rearranged as a consequence of monocular deprivation, as has been demonstrated for layer IVc of the monkey's visual cortex (Hubel, Wiesel & Le Vay, 1977). Images Plate 1 Plate 2 Plate 3 Plate 4 Plate 5 Plate 6 PMID:702379
NASA Astrophysics Data System (ADS)
Schramm, Stefan; Schikowski, Patrick; Lerm, Elena; Kaeding, André; Haueisen, Jens; Baumgarten, Daniel
2016-07-01
Objective measurement of straylight in the human eye with a Shack-Hartmann (SH) wavefront aberrometer is limited in imaging angle. We propose a measurement principle and a point spread function (PSF) reconstruction algorithm to overcome this limitation. In our optical setup, a variable stop replaces the stop conventionally used to suppress reflections and scatter in SH aberrometers. We record images with 21 diameters of the stop. From each SH image, the average intensity of the pupil is computed and normalized. The intensities represent integral values of the PSF. We reconstruct the PSF, which is the derivative of the intensities with respect to the visual angle. A modified Stiles Holladay approximation is fitted to the reconstructed PSF, resulting in a straylight parameter. A proof-of-principle study was carried out on eight healthy young volunteers. Scatter filters were positioned in front of the volunteers' eyes to simulate straylight. The straylight parameter was compared to the C-Quant measurements and the filter values. The PSF parameter shows strong correlation with the density of the filters and a linear relation to the C-Quant straylight parameter. Our measurement and reconstruction techniques allow for objective straylight analysis of visual angles up to 4 deg.
Fast ray-tracing of human eye optics on Graphics Processing Units.
Wei, Qi; Patkar, Saket; Pai, Dinesh K
2014-05-01
We present a new technique for simulating retinal image formation by tracing a large number of rays from objects in three dimensions as they pass through the optic apparatus of the eye to objects. Simulating human optics is useful for understanding basic questions of vision science and for studying vision defects and their corrections. Because of the complexity of computing such simulations accurately, most previous efforts used simplified analytical models of the normal eye. This makes them less effective in modeling vision disorders associated with abnormal shapes of the ocular structures which are hard to be precisely represented by analytical surfaces. We have developed a computer simulator that can simulate ocular structures of arbitrary shapes, for instance represented by polygon meshes. Topographic and geometric measurements of the cornea, lens, and retina from keratometer or medical imaging data can be integrated for individualized examination. We utilize parallel processing using modern Graphics Processing Units (GPUs) to efficiently compute retinal images by tracing millions of rays. A stable retinal image can be generated within minutes. We simulated depth-of-field, accommodation, chromatic aberrations, as well as astigmatism and correction. We also show application of the technique in patient specific vision correction by incorporating geometric models of the orbit reconstructed from clinical medical images. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Working sketch of an anatomically and optically equivalent physical model eye
NASA Astrophysics Data System (ADS)
Bakaraju, Ravi Chandra; Ehrmann, Klaus; Falk, Darrin; Papas, Eric B.; Ho, Arthur
2009-02-01
Our aim was to fabricate a bench-top physical model eye that closely replicates anatomical and optical properties of the average human eye, and to calibrate and standardize this model to suit normal viewing conditions and subsequently utilize it to understand the optical performance of corrective lens designs; especially multifocal soft contact lenses. Using available normative data on ocular biometrics and Zemax ray-tracing software as a tool, we modeled 25, 45 and 55 year-old average adult human eyes with discrete accommodation levels and pupil sizes. Specifications for the components were established following manufacturing tolerance analyses. The cornea was lathed from an optical material with refractive index of 1.376 @ 589 nm and the crystalline lenses were made of Boston RGP polymers with refractive indices of 1.423 (45 & 55yr) and 1.429 (25yr) @ 589 nm. These two materials served to model the equivalent crystalline lens of the different age-groups. A camera, the acting retina, was hosted on the motor-base having translatory and rotary functions to facilitate the simulation of different states of ametropia and peripheral refraction respectively. We report on the implementation of the first prototype and present some simulations of the optical performance of certain contact lenses with specific levels of ametropia, to demonstrate the potential use of such a physical model eye. On completion of development, calibration and standardization, optical quality assessment and performance predictions of different ophthalmic lenses can be studied in great detail. Optical performance with corrective lenses may be reliably simulated and predicted by customized combined computational and physical models giving insight into the merits and pitfalls of their designs
Kaluzhny, Yulia; Kandárová, Helena; Handa, Yuki; DeLuca, Jane; Truong, Thoa; Hunter, Amy; Kearney, Paul; d'Argembeau-Thornton, Laurence; Klausner, Mitchell
2015-05-01
The 7th Amendment to the EU Cosmetics Directive and the EU REACH Regulation have reinforced the need for in vitro ocular test methods. Validated in vitro ocular toxicity tests that can predict the human response to chemicals, cosmetics and other consumer products are required for the safety assessment of materials that intentionally, or inadvertently, come into contact with the eye. The EpiOcular Eye Irritation Test (EIT), which uses the normal human cell-based EpiOcular™ tissue model, was developed to address this need. The EpiOcular-EIT is able to discriminate, with high sensitivity and accuracy, between ocular irritant/corrosive materials and those that require no labelling. Although the original EpiOcular-EIT protocol was successfully pre-validated in an international, multicentre study sponsored by COLIPA (the predecessor to Cosmetics Europe), data from two larger studies (the EURL ECVAM-COLIPA validation study and an independent in-house validation at BASF SE) resulted in a sensitivity for the protocol for solids that was below the acceptance criteria set by the Validation Management Group (VMG) for eye irritation, and indicated the need for improvement of the assay's sensitivity for solids. By increasing the exposure time for solid materials from 90 minutes to 6 hours, the optimised EpiOcular-EIT protocol achieved 100% sensitivity, 68.4% specificity and 84.6% accuracy, thereby meeting all the acceptance criteria set by the VMG. In addition, to satisfy the needs of Japan and the Pacific region, the EpiOcular-EIT method was evaluated for its performance after extended shipment and storage of the tissues (4-5 days), and it was confirmed that the assay performs with similar levels of sensitivity, specificity and reproducibility in these circumstances. 2015 FRAME.
Presumptive keratoglobus in a great horned owl (Bubo virginianus).
Lau, Rachael K; Moresco, Anneke; Woods, Sarah J; Reilly, Christopher M; Hawkins, Michelle G; Murphy, Christopher J; Hollingsworth, Steven R; Hacker, Dennis; Freeman, Kate S
2017-11-01
A juvenile to young adult, male, great horned owl (Bubo virginianus,GHOW) was presented to the wildlife rehabilitation hospital at Lindsay Wildlife Museum (WRHLWM) due to trauma to the right patagium from barbed wire entanglement. On presentation, both corneas were irregular, dry, and no movement of the third eyelid was noted. A severe corneal enlargement/globoid appearance was the predominant ophthalmic feature. The fundus was normal in both eyes (OU). Over the course of several days, both corneas developed edema combined with further dessication at the ocular surface associated with diffuse dorsal fluorescein stain uptake. Repeated ophthalmic examinations found normal intraocular pressures and an inability to move the third eyelid over the enlarged corneas. The bird was deemed nonreleasable due to severe wing damage and poor prognosis associated with eye abnormalities and was humanely euthanized. Postmortem CT, enucleation, and histopathology were performed to evaluate the ocular anatomical abnormality and confirm the suspected diagnosis of keratoglobus. This GHOW represents the first reported case of presumptive keratoglobus in a raptor. © 2016 American College of Veterinary Ophthalmologists.
de Araujo, Aline L; Charoenrook, Victor; de la Paz, Maria F; Temprano, Jose; Barraquer, Rafael I; Michael, Ralph
2012-09-01
To determine the value of electroretinography (ERG) and visual evoked potential (VEP) in predicting visual outcome in patients undergoing osteo-keratoprosthesis (OKP) or osteo-odonto-keratoprosthesis (OOKP) surgery. We performed a retrospective cohort study of 143 eyes in 101 patients who underwent OKP or OOKP surgery. The subjects underwent ERG, VEP testing or both up to 6 months prior to surgery. The ERG and VEP results were classified into four categories based on wave amplitude, latency and configuration. The main outcome was the maximum best-corrected visual acuity (maxBCVA) reached at any time postoperatively. One hundred thirty-four cases had undergone preoperative ERG, 82 VEP and 73 both examinations. The sensitivities of ERG and VEP to detect maxBCVA≥0.05 were 68.5% and 87%, respectively, while the specificity was 63.2% for ERG and 47.4% for VEP. The maxBCVA was significantly better in patients with normal ERG (p=0.033) and those with normal VEP (p=0.048), once having defined appropriate normal and abnormal cut-off levels. When comparing fellow eyes in patients who underwent surgery in both eyes, maxBCVA was better in the eyes that had better VEP results (p=0.013). Eyes demonstrating normal ERG or VEP achieved better visual outcome than those with abnormal results. In addition, VEP proved instrumental in determining the eye with the best prognosis when comparing both eyes of a given patient. © 2011 The Authors. Acta Ophthalmologica © 2011 Acta Ophthalmologica Scandinavica Foundation.
The Initiation of Smooth Pursuit is Delayed in Anisometropic Amblyopia.
Raashid, Rana Arham; Liu, Ivy Ziqian; Blakeman, Alan; Goltz, Herbert C; Wong, Agnes M F
2016-04-01
Several behavioral studies have shown that the reaction times of visually guided movements are slower in people with amblyopia, particularly during amblyopic eye viewing. Here, we tested the hypothesis that the initiation of smooth pursuit eye movements, which are responsible for accurately keeping moving objects on the fovea, is delayed in people with anisometropic amblyopia. Eleven participants with anisometropic amblyopia and 14 visually normal observers were asked to track a step-ramp target moving at ±15°/s horizontally as quickly and as accurately as possible. The experiment was conducted under three viewing conditions: amblyopic/nondominant eye, binocular, and fellow/dominant eye viewing. Outcome measures were smooth pursuit latency, open-loop gain, steady state gain, and catch-up saccade frequency. Participants with anisometropic amblyopia initiated smooth pursuit significantly slower during amblyopic eye viewing (206 ± 20 ms) than visually normal observers viewing with their nondominant eye (183 ± 17 ms, P = 0.002). However, mean pursuit latency in the anisometropic amblyopia group during binocular and monocular fellow eye viewing was comparable to the visually normal group. Mean open-loop gain, steady state gain, and catch-up saccade frequency were similar between the two groups, but participants with anisometropic amblyopia exhibited more variable steady state gain (P = 0.045). This study provides evidence of temporally delayed smooth pursuit initiation in anisometropic amblyopia. After initiation, the smooth pursuit velocity profile in anisometropic amblyopia participants is similar to visually normal controls. This finding differs from what has been observed previously in participants with strabismic amblyopia who exhibit reduced smooth pursuit velocity gains with more catch-up saccades.
Standardized Full-Field Electroretinography in the Green Monkey (Chlorocebus sabaeus)
Bouskila, Joseph; Javadi, Pasha; Palmour, Roberta M.; Bouchard, Jean-François; Ptito, Maurice
2014-01-01
Abstract Full-field electroretinography is an objective measure of retinal function, serving as an important diagnostic clinical tool in ophthalmology for evaluating the integrity of the retina. Given the similarity between the anatomy and physiology of the human and Green Monkey eyes, this species has increasingly become a favorable non-human primate model for assessing ocular defects in humans. To test this model, we obtained full-field electroretinographic recordings (ERG) and normal values for standard responses required by the International Society for Clinical Electrophysiology of Vision (ISCEV). Photopic and scotopic ERG recordings were obtained by full-field stimulation over a range of 6 log units of intensity in dark-adapted or light-adapted eyes of adult Green Monkeys (Chlorocebus sabaeus). Intensity, duration, and interval of light stimuli were varied separately. Reproducible values of amplitude and latency were obtained for the a- and b-waves, under well-controlled adaptation and stimulus conditions; the i-wave was also easily identifiable and separated from the a-b-wave complex in the photopic ERG. The recordings obtained in the healthy Green Monkey matched very well with those in humans and other non-human primate species (Macaca mulatta and Macaca fascicularis). These results validate the Green Monkey as an excellent non-human primate model, with potential to serve for testing retinal function following various manipulations such as visual deprivation or drug evaluation. PMID:25360686
Mycoplasma and associated bacteria isolated from ovine pink-eye.
Langford, E V
1971-01-01
A mycoplasma was recovered from the untreated conjunctival membranes of nine sheep affected by Pink-eye. It was neither isolated from the conjunctiva of treated animals which were affected nor from the conjunctiva of normal animals either in contact or not in contact with affected animals. Bacteria found on normal conjunctival membranes were Neisseria ovis, Escherichia coli, Staphylococcus epidermididis, Streptococcus and Bacillus spp. Bacteria found in clinical cases of Pink-eye were N. ovis, E. coli, a Streptococcus and Pseudomonas spp.
Fabrication of multi-focal microlens array on curved surface for wide-angle camera module
NASA Astrophysics Data System (ADS)
Pan, Jun-Gu; Su, Guo-Dung J.
2017-08-01
In this paper, we present a wide-angle and compact camera module that consists of microlens array with different focal lengths on curved surface. The design integrates the principle of an insect's compound eye and the human eye. It contains a curved hexagonal microlens array and a spherical lens. Compared with normal mobile phone cameras which usually need no less than four lenses, but our proposed system only uses one lens. Furthermore, the thickness of our proposed system is only 2.08 mm and diagonal full field of view is about 100 degrees. In order to make the critical microlens array, we used the inkjet printing to control the surface shape of each microlens for achieving different focal lengths and use replication method to form curved hexagonal microlens array.
Reynaud, Alexandre; Hess, Robert F.
2017-01-01
Several studies have shown that short-term monocular patching can induce ocular dominance plasticity in normal adults, in which the patched eye becomes stronger in binocular viewing. There is a recent study showing that exercise enhances this plasticity effect when assessed with binocular rivalry. We address one question, is this enhancement from exercise a general effect such that it is seen for measures of binocular processing other than that revealed using binocular rivalry? Using a binocular phase combination task in which we directly measure each eye's contribution to the binocularly fused percept, we show no additional effect of exercise after short-term monocular occlusion and argue that the enhancement of ocular dominance plasticity from exercise could not be demonstrated with our approach. PMID:28357142
Zagrodzka, J; Hedberg, C E; Mann, G L; Morrison, A R
1998-06-01
Whether damage to the central nucleus of the amygdala (Ace) contributes to the predatorylike attack sometimes observed in rapid eye movement sleep without atonia (REM-A), created in cats by bilateral pontine lesions, was examined. Such lesions eliminate REM sleep skeletal muscle atonia and release elaborate behavior. Unilateral damage to the Ace alone increased affective defensive aggressive behavior toward humans and conspecifics without altering predatory behavior in wakefulness. Pontine lesions added at loci normally not leading to aggression induced predatorylike attacks in REM-A as well as the waking affective defense. Alterations of autonomic activity, the absence of relevant environmental stimuli in REM-A, or both may explain the state-related differences.
Threat effects on human oculo-motor function.
Naranjo, E N; Cleworth, T W; Allum, J H J; Inglis, J T; Lea, J; Westerberg, B D; Carpenter, M G
2017-09-17
Neuro-anatomical evidence supports the potential for threat-related factors, such as fear, anxiety and vigilance, to influence brainstem motor nuclei controlling eye movements, as well as the vestibular nuclei. However, little is known about how threat influences human ocular responses, such as eye saccades (ES), smooth pursuit eye tracking (SP), and optokinetic nystagmus (OKN), and whether these responses can be facilitated above normal baseline levels with a natural source of threat. This study was designed to examine the effects of height-induced postural threat on the gain of ES, SP and OKN responses in humans. Twenty participants stood at two different surface heights while performing ES (ranging from 8° to 45° from center), SP (15, 20, 30°/s) and OKN (15, 30, 60°/s) responses in the horizontal plane. Height did not significantly increase the slope of the relationship between ES peak velocity and initial amplitude, or the gain of ES amplitude. In contrast height significantly increased SP and OKN gain. Significant correlations were found between changes in physiological arousal and OKN gain. Observations of changes with height in OKN and SP support neuro-anatomical evidence of threat-related mechanisms influencing both oculo-motor nuclei and vestibular reflex pathways. Although further study is warranted, the findings suggest that potential influences of fear, anxiety and arousal/alertness should be accounted for, or controlled, during clinical vestibular and oculo-motor testing. Copyright © 2017 IBRO. Published by Elsevier Ltd. All rights reserved.
Zhang, Ye; Li, Si Zhen; Li, Lei; He, Ming Guang; Thomas, Ravi; Wang, Ning Li
2014-04-24
To estimate and compare the change in iris cross-sectional area (IA) and iris volume (IV) following physiologic and pharmacologic pupil dilation in primary angle closure suspects (PACS) and normal subjects. Anterior segment-optical coherence tomography (AS-OCT) measurements in light, dark, and following pharmacologic dilation were obtained on 186 PACS and 224 normal subjects examined during the 5-year follow-up of the Handan Eye Study. Iris cross-sectional area, IV, and other biometric parameters calculated using the Zhongshan angle assessment program in the right eyes of all subjects were analyzed. The mean IA and IV decreased in dark compared with light and after pharmacologic dilation in both PACS and normal eyes. This change was statistically significant in normal eyes: light versus pharmacologic dilation for IA (P = 0.038) and for IV, both light versus dark (P = 0.031) and light versus pharmacologic dilation (P = 0.012). A longer axial length (P = 0.028) and a greater change in pupil diameter (PD) (P < 0.001) were associated with a larger decrease of IA for the light to dark comparison. A diagnosis of normal eyes (P = 0.011), larger PD in dark (P = 0.001), and a larger change in PD (P = 0.001) were associated with a larger decrease of IV from light to dark. The differences in iris behavior between PACS and normal rural Chinese subjects following physiologic or pharmacologic pupillary dilation may help provide insights into the pathogenesis of angle closure. Copyright 2014 The Association for Research in Vision and Ophthalmology, Inc.
ERIC Educational Resources Information Center
Koretz, Jane F.; Handelman, George H.
1988-01-01
Describes the decline in people's ability to focus their eyes as their age increases. Discusses probable causes of this effect including changes in the eye's geometry and biochemistry. Diagrammatically illustrates age related changes in the lens of the human eye. (CW)
Robust watermark technique using masking and Hermite transform.
Coronel, Sandra L Gomez; Ramírez, Boris Escalante; Mosqueda, Marco A Acevedo
2016-01-01
The following paper evaluates a watermark algorithm designed for digital images by using a perceptive mask and a normalization process, thus preventing human eye detection, as well as ensuring its robustness against common processing and geometric attacks. The Hermite transform is employed because it allows a perfect reconstruction of the image, while incorporating human visual system properties; moreover, it is based on the Gaussian functions derivates. The applied watermark represents information of the digital image proprietor. The extraction process is blind, because it does not require the original image. The following techniques were utilized in the evaluation of the algorithm: peak signal-to-noise ratio, the structural similarity index average, the normalized crossed correlation, and bit error rate. Several watermark extraction tests were performed, with against geometric and common processing attacks. It allowed us to identify how many bits in the watermark can be modified for its adequate extraction.
Spatial interactions reveal inhibitory cortical networks in human amblyopia.
Wong, Erwin H; Levi, Dennis M; McGraw, Paul V
2005-10-01
Humans with amblyopia have a well-documented loss of sensitivity for first-order, or luminance defined, visual information. Recent studies show that they also display a specific loss of sensitivity for second-order, or contrast defined, visual information; a type of image structure encoded by neurons found predominantly in visual area A18/V2. In the present study, we investigate whether amblyopia disrupts the normal architecture of spatial interactions in V2 by determining the contrast detection threshold of a second-order target in the presence of second-order flanking stimuli. Adjacent flanks facilitated second-order detectability in normal observers. However, in marked contrast, they suppressed detection in each eye of the majority of amblyopic observers. Furthermore, strabismic observers with no loss of visual acuity show a similar pattern of detection suppression. We speculate that amblyopia results in predominantly inhibitory cortical interactions between second-order neurons.
Human Erythropoietin Effect in Postoperative Visual Loss Following Spine Surgery: A Case Report
Hassani, Valiollah; Homaei, Mohammad Mohsen; Shahbazi, Ali; Zamani, Mohammad Mahdi; Safari, Saeid; Nadi, Shermila; Rahimizadeh, Abolfazl; Lashkari, Mohammad Hossein; Alizadeh zendehrood, Siamak
2014-01-01
Introduction: Postoperative visual loss (POVL) has become the focus of attention for anesthesiologists as a hallmark of perioperative management in spine surgery. A number of Intraoperative and postoperative factors has been documented but the exact etiology is still unclear. Nowadays, perioperative management and also complete curing of POLV is a big question of ophthalmologists and anesthesiologists. The purpose of this case report is to present a unique experience of complete curing the POLV. Case Presentation: Our patient was a 61-year-old man, with 75 kg weight and 180 cm height. The patient had no history of visual impairment except mild cataract in his right eye. The patient had a history of diffuse idiopathic skeletal hyperostosis (DISH). The patient had undergone lumbar surgery in prone position. The operation time was about 6 hours. About 30 minutes after transferring to postanesthesia care unit (PACU), patient was awake and complained of losing his eyesight. There was no vision and light perception in his right eye on primary examination. Urgent ophthalmologist consultation was requested. In ophthalmology examinations, the pupil reflex to light was absent in the right eye. After obtaining patients and his family informed consent, four hours after the operation, 40000 I.U. of recombinant human erythropoietin (rhEPO) was administered for patient in PACU (IV infusion, in 30 min). An ophthalmologist visited him every 6 hours after administration of rhEPO. The patient was transferred to intensive care unit (ICU) one hour later with total visual loss in the right eye. Ophthalmologic examination after the second dose of rhEPO, 30 hours after the operation, reported pupil reflex enhancement and light perception in his right eye. Finally the third dose of rhEPO (40000 I.U., IV infusion) was administered on the third day. Ophthalmologic examination after the third dose of rhEPO, 60 hours after the operation, reported normal pupillary light reflex of the right eye and visual acuity improvement to 20/20. The patient was discharged from hospital after six days, with normal visual acuity and without any new complications except surgical site pain. Conclusions: Our case report showed the therapeutic effect of rhEPO in complete curing of POVL. Regarding the side effects of EPO such as thrombogenic effects or mild hemodynamic changes like transient sinus tachycardia during infusion, it seems that beneficial effects of EPO is more than its disadvantages and expenses, for patients with POVL. PMID:24790903
Sensory Eye Dominance in Treated Anisometropic Amblyopia
Chen, Yao
2017-01-01
Amblyopia results from inadequate visual experience during the critical period of visual development. Abnormal binocular interactions are believed to play a critical role in amblyopia. These binocular deficits can often be resolved, owing to the residual visual plasticity in amblyopes. In this study, we quantitatively measured the sensory eye dominance in treated anisometropic amblyopes to determine whether they had fully recovered. Fourteen treated anisometropic amblyopes with normal or corrected to normal visual acuity participated, and their sensory eye dominance was assessed by using a binocular phase combination paradigm. We found that the two eyes were unequal in binocular combination in most (11 out of 14) of our treated anisometropic amblyopes, but none of the controls. We concluded that the treated anisometropic amblyopes, even those with a normal range of visual acuity, exhibited abnormal binocular processing. Our results thus suggest that there is potential for improvement in treated anisometropic amblyopes that may further enhance their binocular visual functioning. PMID:28573051
Ultrasonography of the eye and orbit.
Eisenberg, H M
1985-11-01
The eye and orbit are excellent subjects for ultrasonic evaluation. Examination and interpretation are relatively simple procedures. The normal ultrasonic anatomy of the eye and orbit is presented. Some examples of ocular and orbital pathology are discussed also.
Choudhury, Minati; Banu, Fathima; Natarajan, Shanmuganathan; Kumar, Anand; Tv, Padmanabhan
2018-02-16
Interdisciplinary prosthodontics goes beyond our imagination into fields that have a direct effect on our total body health and quality of life. Removal of an eye has a detrimental effect on the psychology of the patient. Enucleation involves removal of the eyeball proper and leads to an enophthalmic socket with a shrunken eye, which has a crippling effect on patient's emotional and social life. Custom-made eye prosthesis simulates the characteristics of the companion eye and helps in restoring the normal facial appearance. Restoration of saccadic eye movements occurring during speech is desirable because this greatly contributes to a normal facial expression. This can be achieved by an orbital implant, which helps in orbital volume replacement and restoration of prosthesis movement and comfort. This article describes prosthodontic rehabilitation of enucleated eye sockets with orbital implants for two patients.
Siddiqi, M A; Kilduff, G M; Gearhart, J D
2003-11-01
We describe the design, construction and testing of a prototype device that allows the direct visualization by eye of far-red and near-infrared (NIR) fluorescence through an optical microscope. The device incorporates a gallium arsenide (GaAs) image intensifier, typically utilized in low-light or 'night vision' applications. The intensifier converts far-red and NIR light into electrons and then into green light, which is visible to the human eye. The prototype makes possible the direct, real-time viewing by eye of normally invisible far-red and NIR fluorescence from a wide variety of fluorophores, using the full field of view of the microscope to which it is applied. The high sensitivity of the image intensifier facilitates the viewing of a wide variety of photosensitive specimens, including live cells and embryos, at vastly reduced illumination levels in both fluorescence and bright-field microscopy. Modifications to the microscope are not required in order to use the prototype, which is fully compatible with all current fluorescence techniques. Refined versions of the prototype device will have broad research and clinical applications.
Song, Hong-Yan; Qiu, Bao-Feng; Liu, Chun; Zhu, Shun-Xing; Wang, Sheng-Cun; Miao, Jin; Jing, Jing; Shao, Yi-Xiang
2014-01-01
The clone library method using PCR amplification of the 16S ribosomal RNA (rRNA) gene was used to identify pathogens from corneal scrapings of C57BL/6-corneal opacity (B6-Co) mice with bacterial keratitis. All 10 samples from the eyes with bacterial keratitis showed positive PCR results. All 10 samples from the normal cornea showed negative PCR results. In all 10 PCR-positive samples, the predominant and second most predominant species accounted for 20.9 to 40.6% and 14.7 to 26.1%, respectively, of each clone library. The predominant species were Staphylococcus lentus, Pseudomonas aeruginosa, and Staphylococcus epidermidis. The microbiota analysis detected a diverse group of microbiota in the eyes of B6-Co mice with bacterial keratitis and showed that the causative pathogens could be determined based on percentages of bacterial species in the clone libraries. The bacterial species detected in this study were mostly in accordance with results of studies on clinical bacterial keratitis in human eyes. Based on the results of our previous studies and this study, the B6-Co mouse should be considered a favorable model for studying bacterial keratitis. PMID:25312507
Simulation of Thin Film Equations on an Eye-Shaped Domain with Moving Boundary
NASA Astrophysics Data System (ADS)
Brosch, Joseph; Driscoll, Tobin; Braun, Richard
During a normal eye blink, the upper lid moves, and during the upstroke the lid paints a thin tear film over the exposed corneal and conjunctival surfaces. This thin tear film may be modeled by a nonlinear fourth-order PDE derived from lubrication theory. A major stumbling block in the numerical simulation of this model is to include both the geometry of the eye and the movement of the eyelid. Using a pair of orthogonal and conformal maps, we transform a computational box into a rough representation of a human eye where we proceed to simulate the thin tear film equations. Although we give up some realism, we gain spectrally accurate numerical methods on the computational box. We have applied this method to the heat equation on the blinking domain with both Dirichlet and no-flux boundary conditions, in each case demonstrating at least 10 digits of accuracy.. We are able to perform these simulations very quickly (generally in under a minute) using a desktop version of MATLAB. This project was supported by Grant 1022706 (R.J.B., T.A.D., J.K.B.) from the NSF.
Chen, Yi-Chuan; Lewis, Terri L; Shore, David I; Maurer, Daphne
2017-02-20
Temporal simultaneity provides an essential cue for integrating multisensory signals into a unified perception. Early visual deprivation, in both animals and humans, leads to abnormal neural responses to audiovisual signals in subcortical and cortical areas [1-5]. Behavioral deficits in integrating complex audiovisual stimuli in humans are also observed [6, 7]. It remains unclear whether early visual deprivation affects visuotactile perception similarly to audiovisual perception and whether the consequences for either pairing differ after monocular versus binocular deprivation [8-11]. Here, we evaluated the impact of early visual deprivation on the perception of simultaneity for audiovisual and visuotactile stimuli in humans. We tested patients born with dense cataracts in one or both eyes that blocked all patterned visual input until the cataractous lenses were removed and the affected eyes fitted with compensatory contact lenses (mean duration of deprivation = 4.4 months; range = 0.3-28.8 months). Both monocularly and binocularly deprived patients demonstrated lower precision in judging audiovisual simultaneity. However, qualitatively different outcomes were observed for the two patient groups: the performance of monocularly deprived patients matched that of young children at immature stages, whereas that of binocularly deprived patients did not match any stage in typical development. Surprisingly, patients performed normally in judging visuotactile simultaneity after either monocular or binocular deprivation. Therefore, early binocular input is necessary to develop normal neural substrates for simultaneity perception of visual and auditory events but not visual and tactile events. Copyright © 2017 Elsevier Ltd. All rights reserved.
Maekubo, Tomoyuki; Chuman, Hideki; Nao-I, Nobuhisa
2013-07-01
The aim of this study was to investigate the usefulness of laser speckle flowgraphy (LSFG) for the differentiation of acute nonarteritic ischemic optic neuropathy (NAION) from anterior optic neuritis (ON). To investigate blood flow in the optic disc under normal conditions, NAION, and anterior ON, we compared the tissue blood flow of the right eye with that of the left eye in the control group, and that of the affected eye with that of the unaffected eye in the NAION and anterior ON groups. In the normal control group, the tissue blood flow did not significantly differ between the right and left eyes. In the NAION group, all 6 patients had decreased optic disc blood flow in the NAION eye when compared with the unaffected eye. By contrast, in the anterior ON group, all 6 patients had increased optic disc blood flow in the anterior ON eye when compared with the unaffected eye. In the NAION group, the mean blur rate (MBR) of the affected eyes was 29.5 % lower than that of the unaffected eyes. In the anterior ON group, the MBR of the affected eyes was 15.9 % higher than that of the unaffected eyes. LSFG could be useful in differentiating between NAION and anterior ON. In addition, this imaging technique saves time and is noninvasive.
New screening methods for donor eye-bank eyes.
Terry, M A; Ousley, P J
1999-07-01
Current methods of screening donor eyes for corneal transplantation are not always effective in excluding corneas with abnormal topography. We used the Orbscan to determine whether corneal-thickness maps could be used as a technique for donor tissue screening. Forty eye-bank eyes were measured with the Orbscan, and a corneal-thickness map was generated. Average central pachymetry measurements from each map were compared with the thinnest midperipheral thickness reading. Two eyes from a donor who had photorefractive keratectomy (PRK) and two eyes from a donor with keratoconus were then compared with the normal donor eye results. The average difference between the thinnest midperipheral pachymetry and the central pachymetry in the control group was 0.040 +/- 0.026 mm. The eyes from the donor with PRK showed larger disparities between the central and midperipheral thicknesses because of the thinned central cornea, with differences of 0.154 mm in the right eye and 0.106 mm in the left eye. The eyes from the donor with keratoconus had midperipheral corneas that were thinner than the center, indicating eccentric, ectatic cones. The differences in thickness between the center and midperiphery in the eyes from the donor with PRK and the donor with keratoconus differed from the control group by >2 SD. Diseases or surgery that affect the relationship between the central and midperipheral corneal thickness may be screened through Orbscan pachymetry mapping with comparison with a normal range.
Teper, Sławomir J.; Janiszewska, Dominika A.; Lyssek-Boron, Anita; Dobrowolski, Dariusz; Koprowski, Robert; Wylegala, Edward
2015-01-01
Purpose. To compare anterior eye segment measurements and morphology obtained with two optical coherence tomography systems (TD OCT, SS OCT) in eyes with corneal dystrophies (CDs). Methods. Fifty healthy volunteers (50 eyes) and 54 patients (96 eyes) diagnosed with CD (epithelial basement membrane dystrophy, EBMD = 12 eyes; Thiel-Behnke CD = 6 eyes; lattice CD TGFBI type = 15 eyes; granular CD type 1 = 7 eyes, granular CD type 2 = 2 eyes; macular CD = 23 eyes; and Fuchs endothelial CD = 31 eyes) were recruited for the study. Automated and manual central corneal thickness (aCCT, mCCT), anterior chamber depth (ACD), and nasal and temporal trabecular iris angle (nTIA, tTIA) were measured and compared with Bland-Altman plots. Results. Good agreement between the TD and SS OCT measurements was demonstrated for mCCT and aCCT in normal individuals and for mCCT in the CDs group. The ACD, nTIA, and tTIA measurements differed significantly in both groups. TBCD, LCD, and FECD caused increased CCT. MCD caused significant corneal thinning. FECD affected all analyzed parameters. Conclusions. Better agreement between SS OCT and TD OCT measurements was demonstrated in normal individuals compared to the CDs group. OCT provides comprehensive corneal deposits analysis and demonstrates the association of CD with CCT, ACD, and TIA measurements. PMID:26457303
Nowinska, Anna K; Teper, Sławomir J; Janiszewska, Dominika A; Lyssek-Boron, Anita; Dobrowolski, Dariusz; Koprowski, Robert; Wylegala, Edward
2015-01-01
To compare anterior eye segment measurements and morphology obtained with two optical coherence tomography systems (TD OCT, SS OCT) in eyes with corneal dystrophies (CDs). Fifty healthy volunteers (50 eyes) and 54 patients (96 eyes) diagnosed with CD (epithelial basement membrane dystrophy, EBMD = 12 eyes; Thiel-Behnke CD = 6 eyes; lattice CD TGFBI type = 15 eyes; granular CD type 1 = 7 eyes, granular CD type 2 = 2 eyes; macular CD = 23 eyes; and Fuchs endothelial CD = 31 eyes) were recruited for the study. Automated and manual central corneal thickness (aCCT, mCCT), anterior chamber depth (ACD), and nasal and temporal trabecular iris angle (nTIA, tTIA) were measured and compared with Bland-Altman plots. Good agreement between the TD and SS OCT measurements was demonstrated for mCCT and aCCT in normal individuals and for mCCT in the CDs group. The ACD, nTIA, and tTIA measurements differed significantly in both groups. TBCD, LCD, and FECD caused increased CCT. MCD caused significant corneal thinning. FECD affected all analyzed parameters. Better agreement between SS OCT and TD OCT measurements was demonstrated in normal individuals compared to the CDs group. OCT provides comprehensive corneal deposits analysis and demonstrates the association of CD with CCT, ACD, and TIA measurements.
Biomechanical Changes in the Sclera of Monkey Eyes Exposed to Chronic IOP Elevations
Girard, Michaël J. A.; Suh, J.-K. Francis; Bottlang, Michael; Burgoyne, Claude F.
2011-01-01
Purpose. To characterize scleral biomechanics in both eyes of eight monkeys in which chronic intraocular pressure (IOP) elevation was induced in one eye. Methods. Each posterior sclera was mounted on a pressurization apparatus, IOP was elevated from 5 to 45 mm Hg while the 3D displacements of the scleral surface were measured by speckle interferometry. Finite element (FE) models of each scleral shell were constructed that incorporated stretch-induced stiffening and multidirectionality of the collagen fibers. FE model predictions were then iteratively matched to experimental displacements to extract unique sets of scleral biomechanical properties. Results. For all eyes, the posterior sclera exhibited inhomogeneous, anisotropic, nonlinear biomechanical behavior. Biomechanical changes caused by chronic IOP elevation were complex and specific to each subject. Specifically: (1) Glaucomatous eyes in which the contralateral normal eyes displayed large modulus or thickness were less prone to biomechanical changes; (2) glaucomatous scleral modulus associated with an IOP of 10 mm Hg decreased (when compared with that of the contralateral normal) after minimal chronic IOP elevation; (3) glaucomatous scleral modulus associated with IOPs of 30 and 45 mm Hg increased (when compared with that of the contralateral normal) after moderate IOP elevation; and (4) FE-based estimates of collagen fiber orientation demonstrated no change in the glaucomatous eyes. Conclusions. Significant stiffening of the sclera follows exposure to moderate IOP elevations in most eyes. Scleral hypercompliance may precede stiffening or be a unique response to minimal chronic IOP elevation in some eyes. These biomechanical changes are likely to be the result of scleral extracellular matrix remodeling. PMID:21519033
Chen, Henry Shen-Lih; Liu, Chun-Hsiu; Lu, Da-Wen
2016-01-01
Background/Purpose: To evaluate and compare the diagnostic discriminative ability for detecting glaucoma in highly myopic eyes from a normative database of macular ganglion cell complex (mGCC) thickness based on nonhighly myopic and highly myopic normal eyes. Methods: Forty-nine eyes of 49 participants with high myopia (axial length ≥ 26.0 mm) were enrolled. Spectral-domain optical coherence tomography scans were done using RS-3000, and the mGCC thickness/significance maps within a 9-mm diameter circle were generated using built-in software. We compared the difference of sensitivity, specificity, and diagnostic accuracy between the nonhighly myopic database and the highly myopic database for differentiating the early glaucomatous eyes from the nonglaucomatous eyes. Results: This study enrolled 15 normal eyes and 34 eyes with glaucoma. The mean mGCC thickness of the glaucoma group was significantly less than that of the normal group (p < 0.001). Sensitivity was 96.3%, and the specificity was 50.0% when using the nonhighly myopic normative database. When the highly myopic normative database was used, the sensitivity was 88.9%, and the specificity was 90.0%. The false positive rate was significantly lower when using the highly myopic normative database (p < 0.05). Conclusion: The evaluations of glaucoma in eyes with high myopia using a nonhighly myopic normative database may lead to a frequent misdiagnosis. When evaluating glaucoma in high myopic eyes, the mGCC thickness determined by the long axial length high myopic normative database should be applied. PMID:29018704
The Cerebellar Dysplasia of Chiari II Malformation as Revealed by Eye Movements
Salman, Michael S.; Dennis, Maureen; Sharpe, James A.
2011-01-01
Introduction Chiari type II malformation (CII) is a developmental deformity of the hindbrain. We have previously reported that many patients with CII have impaired smooth pursuit, while few make inaccurate saccades or have an abnormal vestibulo-ocular reflex. In contrast, saccadic adaptation and visual fixation are normal. In this report, we correlate results from several eye movement studies with neuroimaging in CII. We present a model for structural changes within the cerebellum in CII. Methods Saccades, smooth pursuit, the vestibulo-ocular reflex, and visual fixation were recorded in 21 patients with CII, aged 8–19 years and 39 age-matched controls, using an infrared eye tracker. Qualitative and quantitative MRI data were correlated with eye movements in 19 CII patients and 28 controls. Results Nine patients with CII had abnormal eye movements. Smooth pursuit gain was subnormal in eight, saccadic accuracy abnormal in four, and vestibulo-ocular reflex gain abnormal in three. None had fixation instability. Patients with CII had a significantly smaller cerebellar volume than controls, and those with normal eye motion had an expanded midsagittal vermis compared to controls. However, patients with abnormal eye movements had a smaller (non-expanded) midsagittal vermis area, posterior fossa area and medial cerebellar volumes than CII patients with normal eye movements. Conclusions The deformity of CII affects the structure and function of the cerebellum selectively and differently in those with abnormal eye movements. We propose that the vermis can expand when compressed within a small posterior fossa in some CII patients, thus sparing its ocular motor functions. PMID:19960749
Zayit-Soudry, Shiri; Duncan, Jacque L; Syed, Reema; Menghini, Moreno; Roorda, Austin J
2013-11-15
To evaluate cone spacing using adaptive optics scanning laser ophthalmoscopy (AOSLO) in eyes with nonneovascular AMD, and to correlate progression of AOSLO-derived cone measures with standard measures of macular structure. Adaptive optics scanning laser ophthalmoscopy images were obtained over 12 to 21 months from seven patients with AMD including four eyes with geographic atrophy (GA) and four eyes with drusen. Adaptive optics scanning laser ophthalmoscopy images were overlaid with color, infrared, and autofluorescence fundus photographs and spectral domain optical coherence tomography (SD-OCT) images to allow direct correlation of cone parameters with macular structure. Cone spacing was measured for each visit in selected regions including areas over drusen (n = 29), at GA margins (n = 14), and regions without drusen or GA (n = 13) and compared with normal, age-similar values. Adaptive optics scanning laser ophthalmoscopy imaging revealed continuous cone mosaics up to the GA edge and overlying drusen, although reduced cone reflectivity often resulted in hyporeflective AOSLO signals at these locations. Baseline cone spacing measures were normal in 13/13 unaffected regions, 26/28 drusen regions, and 12/14 GA margin regions. Although standard clinical measures showed progression of GA in all study eyes, cone spacing remained within normal ranges in most drusen regions and all GA margin regions. Adaptive optics scanning laser ophthalmoscopy provides adequate resolution for quantitative measurement of cone spacing at the margin of GA and over drusen in eyes with AMD. Although cone spacing was often normal at baseline and remained normal over time, these regions showed focal areas of decreased cone reflectivity. These findings may provide insight into the pathophysiology of AMD progression. (ClinicalTrials.gov number, NCT00254605).
Cone Integrity in Glaucoma: An Adaptive-Optics Scanning Laser Ophthalmoscopy Study.
Hasegawa, Tomoko; Ooto, Sotaro; Takayama, Kohei; Makiyama, Yukiko; Akagi, Tadamichi; Ikeda, Hanako O; Nakanishi, Hideo; Suda, Kenji; Yamada, Hiroshi; Uji, Akihito; Yoshimura, Nagahisa
2016-11-01
To investigate photoreceptor changes in eyes with glaucoma. Cross-sectional study. The study included 35 eyes of 35 patients with primary open-angle glaucoma who had suffered parafoveal visual field loss at least 3 years previously, as well as 21 eyes of 21 normal subjects. Eyes with an axial length ≥26.0 mm were excluded. All subjects underwent a full ophthalmologic examination, including spectral-domain optical coherence tomography (SDOCT) and prototype adaptive-optics scanning laser ophthalmoscopy (AO-SLO) imaging. As determined using AO-SLO, eyes with glaucoma did not differ significantly from normal eyes in terms of either cone density (26 468 ± 3392 cones/m 2 vs 26 147 ± 2700 cones/m 2 , respectively; P = .77; measured 0.5 mm from the foveal center) or cone spatial organization (ratio of hexagonal Voronoi domain: 43.7% ± 4.4% vs 44.3% ± 4.9%; P = .76; measured 0.5 mm from the foveal center). Furthermore, SDOCT showed that the 2 groups did not differ significantly in terms of the photoreceptor-related layer thickness, and that the photoreceptor ellipsoid zone band was continuous in all normal and glaucoma eyes. In glaucoma eyes with vertically asymmetric severity, the more affected side did not significantly differ from the less affected side in terms of cone density, cone spatial organization, or photoreceptor-related layer thickness. In 8 eyes (22.9%) with glaucoma, dark, partition-like areas surrounded the cones on the AO-SLO. Both AO-SLO and SDOCT showed cone integrity in eyes with glaucoma, even in areas with visual field and nerve fiber loss. In AO-SLO, microcystic lesions in the inner nuclear layer may influence images of the cone mosaic. Copyright © 2016 Elsevier Inc. All rights reserved.
Sredar, Nripun; Ivers, Kevin M.; Queener, Hope M.; Zouridakis, George; Porter, Jason
2013-01-01
En face adaptive optics scanning laser ophthalmoscope (AOSLO) images of the anterior lamina cribrosa surface (ALCS) represent a 2D projected view of a 3D laminar surface. Using spectral domain optical coherence tomography images acquired in living monkey eyes, a thin plate spline was used to model the ALCS in 3D. The 2D AOSLO images were registered and projected onto the 3D surface that was then tessellated into a triangular mesh to characterize differences in pore geometry between 2D and 3D images. Following 3D transformation of the anterior laminar surface in 11 normal eyes, mean pore area increased by 5.1 ± 2.0% with a minimal change in pore elongation (mean change = 0.0 ± 0.2%). These small changes were due to the relatively flat laminar surfaces inherent in normal eyes (mean radius of curvature = 3.0 ± 0.5 mm). The mean increase in pore area was larger following 3D transformation in 4 glaucomatous eyes (16.2 ± 6.0%) due to their more steeply curved laminar surfaces (mean radius of curvature = 1.3 ± 0.1 mm), while the change in pore elongation was comparable to that in normal eyes (−0.2 ± 2.0%). This 3D transformation and tessellation method can be used to better characterize and track 3D changes in laminar pore and surface geometries in glaucoma. PMID:23847739
Effect of Intravenous Mannitol on Intraocular Pressure in Vitrectomized Silicone-Oil-Filled Eyes.
Takkar, Brijesh; Chandra, Parijat; Shah, Ritu; Bhatia, Indrish; Roy, Sangeeta; Sihota, Ramanjit
2017-01-01
To evaluate the effect of intravenous mannitol (IVM) on intraocular pressure (IOP) in vitrectomized eyes. Thirty-one patients with raised IOP after retinal surgery with silicone oil injection were included. Patients were administered IVM (20% solution, 1g/Kg, over 30 minutes) and IOP was noted at regular intervals. IOP reduction in vitrectomized eyes (Group 1) was compared with the normal eyes (Group 2). Percentage IOP reduction was higher in Group 1 than in Group 2 at all time intervals, 24.5% vs. 19.2% at 15 minutes (p=0.34), 22.6% vs. 9.8% at 45 minutes (p=0.003), 19.1% vs. 9.9% at two hours (p=0.023), and 16.1% vs. 7.8% at four hours (p=0.04), respectively. In Group 1, 40% eyes had an IOP reduction of 2-6 mmHg while 30% eyes had IOP reduction >6 mmHg at four hours post-IVM. IVM is useful for short-term IOP reduction in vitrectomized eyes. IOP reduction is independent of baseline IOP, and sustained and higher as compared to normal eyes.
Flügel-Koch, Cassandra M; Tektas, Ozan Y; Kaufman, Paul L; Paulsen, Friedrich P; Lütjen-Drecoll, Elke
2014-06-17
To analyze the peripheral fixation of the iris dilator muscle in normal eyes and in eyes with pigmentary glaucoma (PG). Using 63 control eyes (age 18 months-99 years), the peripheral iris dilator was investigated by light microscopy, immunohistochemistry, and electron microscopy. Development was studied using 18 differently aged fetal eyes stained immunohistochemically against α-smooth muscle (SM) actin. The peripheral iris dilator muscle in PG was analyzed using semithin and ultrathin sections of six glutaraldehyde-fixed eyes from three donors aged 38, 62, and 74 years. In normal eyes, the peripheral end of the iris dilator muscle is arranged in a sphincter-like manner. Arcade-shaped tendinous connections associated with myofibroblasts (iridial strands) anchor the iris dilator within the elastic-fibromuscular ciliary meshwork that also serves as fixation area for the elastic tendons of the inner ciliary muscle portions. The iridial strands are innervated and can adapt their length during accommodation. The PG eyes show incomplete circular bundles and iridial strands that are mainly anchored to the iris stroma and the flexible uveal parts of the trabecular meshwork. The normal anchorage of the peripheral iris dilator and its presumably neuronally regulated length adaptation stabilize the peripheral iris during accommodation. Insufficient fixation in PG could promote posterior bowing of the iris with rubbing against the zonular fibers and pigment liberation from the iris pigmented epithelium. Copyright 2014 The Association for Research in Vision and Ophthalmology, Inc.
Doi, Takahiro; Fujita, Ichiro
2014-01-01
Three-dimensional visual perception requires correct matching of images projected to the left and right eyes. The matching process is faced with an ambiguity: part of one eye's image can be matched to multiple parts of the other eye's image. This stereo correspondence problem is complicated for random-dot stereograms (RDSs), because dots with an identical appearance produce numerous potential matches. Despite such complexity, human subjects can perceive a coherent depth structure. A coherent solution to the correspondence problem does not exist for anticorrelated RDSs (aRDSs), in which luminance contrast is reversed in one eye. Neurons in the visual cortex reduce disparity selectivity for aRDSs progressively along the visual processing hierarchy. A disparity-energy model followed by threshold nonlinearity (threshold energy model) can account for this reduction, providing a possible mechanism for the neural matching process. However, the essential computation underlying the threshold energy model is not clear. Here, we propose that a nonlinear modification of cross-correlation, which we term “cross-matching,” represents the essence of the threshold energy model. We placed half-wave rectification within the cross-correlation of the left-eye and right-eye images. The disparity tuning derived from cross-matching was attenuated for aRDSs. We simulated a psychometric curve as a function of graded anticorrelation (graded mixture of aRDS and normal RDS); this simulated curve reproduced the match-based psychometric function observed in human near/far discrimination. The dot density was 25% for both simulation and observation. We predicted that as the dot density increased, the performance for aRDSs should decrease below chance (i.e., reversed depth), and the level of anticorrelation that nullifies depth perception should also decrease. We suggest that cross-matching serves as a simple computation underlying the match-based disparity signals in stereoscopic depth perception. PMID:25360107
Dias, Diego T; Ushida, Michele; Sousa, Marina C; Dorairaj, Syril; Biteli, Luis G; Leite, Mauro T; Paranhos, Augusto; Prata, Tiago S
2016-01-01
Among all glaucoma suspects, eyes with optic nerve head features suspicious or suggestive of early glaucoma are probably those that offer the greatest challenge for clinicians. In contrast with the robust longitudinal data published on ocular hypertension, there is no specific management guideline for these patients. Therefore, evaluating eyes with suspicious optic disc appearance and normal intraocular pressure (IOP), we sought to investigate potential differences in clinical and epidemiological characteristics to differentiate those with normal-tension glaucoma (NTG) from those with presumed large physiological optic disc cups (pLPC). In this observational case-control study, we consecutively enrolled individuals with pLPC and NTG. All eyes had vertical cup-to-disc ratio (VCDR)≥0.6 and untreated IOP<21 mmHg. Glaucomatous eyes had reproducible visual field defects. Eyes with pLPC required normal visual fields and ≥30 months of follow-up with no evidence of glaucomatous neuropathy. Clinical and epidemiological parameters were compared between groups. Eighty-four individuals with pLPC and 40 NTG patients were included. Regarding our main results, NTG patients were significantly older and with a higher prevalence of Japanese descendants (p<0.01). Not only did pLPC eyes have smaller mean VCDR, but also larger optic discs (p≤0.04). There were no significant differences for gender, central corneal thickness, and spherical equivalent (p≥0.38). Significant odds ratios (OR) were found for race (OR = 2.42; for Japanese ancestry), age (OR = 1.05), VCDR (OR = 5.03), and disc size (OR = 0.04; p≤0.04). In conclusion, in patients with suspicious optic disc and normal IOP, those with older age, Japanese ancestry, smaller optic discs, and larger VCDR are more likely to have NTG, and therefore, deserve deeper investigation and closer monitoring.
Retinal pulse wave velocity measurement using spectral-domain optical coherence tomography.
Li, Qian; Li, Lin; Fan, Shanhui; Dai, Cuixia; Chai, Xinyu; Zhou, Chuanqing
2018-02-01
The human eyes provide a natural window for noninvasive measurement of the pulse wave velocity (PWV) of small arteries. By measuring the retinal PWV, the stiffness of small arteries can be assessed, which may better detect early vascular diseases. Therefore, retinal PWV measurement has attracted increasing attention. In this study, a jump-scanning method was proposed for noninvasive measurement of retinal PWV using spectral-domain optical coherence tomography (SD-OCT). The jump-scanning method uses the phase-resolved Doppler OCT to obtain the pulse shapes. To realize PWV measurement, the jump-scanning method extracts the transit time of the pulse wave from an original OCT scanning site to another through a transient jump. The measured retinal arterial PWV of a young human subject with normal blood pressure was in the order of 20 to 30 mm/s, which was consistent with previous studies. As a comparison, PWV of 50 mm/s was measured for a young human subject with prehypertension, which was in accordance with the finding of strong association between retinal PWV and blood pressure. In summary, it is believed the proposed jump-scanning method could benefit the research and diagnosis of vascular diseases through the window of human eyes. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Multiconjugate adaptive optics applied to an anatomically accurate human eye model.
Bedggood, P A; Ashman, R; Smith, G; Metha, A B
2006-09-04
Aberrations of both astronomical telescopes and the human eye can be successfully corrected with conventional adaptive optics. This produces diffraction-limited imagery over a limited field of view called the isoplanatic patch. A new technique, known as multiconjugate adaptive optics, has been developed recently in astronomy to increase the size of this patch. The key is to model atmospheric turbulence as several flat, discrete layers. A human eye, however, has several curved, aspheric surfaces and a gradient index lens, complicating the task of correcting aberrations over a wide field of view. Here we utilize a computer model to determine the degree to which this technology may be applied to generate high resolution, wide-field retinal images, and discuss the considerations necessary for optimal use with the eye. The Liou and Brennan schematic eye simulates the aspheric surfaces and gradient index lens of real human eyes. We show that the size of the isoplanatic patch of the human eye is significantly increased through multiconjugate adaptive optics.
Rajjoub, Raneem D; Trimboli-Heidler, Carmelina; Packer, Roger J; Avery, Robert A
2015-01-01
To determine the intra- and intervisit reproducibility of circumpapillary retinal nerve fiber layer (RNFL) thickness measures using eye tracking-assisted spectral-domain optical coherence tomography (SD OCT) in children with nonglaucomatous optic neuropathy. Prospective longitudinal study. Circumpapillary RNFL thickness measures were acquired with SD OCT using the eye-tracking feature at 2 separate study visits. Children with normal and abnormal vision (visual acuity ≥ 0.2 logMAR above normal and/or visual field loss) who demonstrated clinical and radiographic stability were enrolled. Intra- and intervisit reproducibility was calculated for the global average and 9 anatomic sectors by calculating the coefficient of variation and intraclass correlation coefficient. Forty-two subjects (median age 8.6 years, range 3.9-18.2 years) met inclusion criteria and contributed 62 study eyes. Both the abnormal and normal vision cohort demonstrated the lowest intravisit coefficient of variation for the global RNFL thickness. Intervisit reproducibility remained good for those with normal and abnormal vision, although small but statistically significant increases in the coefficient of variation were observed for multiple anatomic sectors in both cohorts. The magnitude of visual acuity loss was significantly associated with the global (ß = 0.026, P < .01) and temporal sector coefficient of variation (ß = 0.099, P < .01). SD OCT with eye tracking demonstrates highly reproducible RNFL thickness measures. Subjects with vision loss demonstrate greater intra- and intervisit variability than those with normal vision. Copyright © 2015 Elsevier Inc. All rights reserved.
Influence of Ophthalmic Solutions on Tear Components.
Shigeyasu, Chika; Yamada, Masakazu; Akune, Yoko
2016-11-01
Tear fluids are a mixture of secretions derived from lacrimal glands, accessory lacrimal glands, conjunctiva, and meibomian glands. Compositional changes to tears occur in the normal state and during ocular surface disease, such as dry eye conditions. We have investigated compositional changes to tears after topical application of ophthalmic solutions, with regard to tear-specific proteins (secretory immunoglobulin A, lactoferrin, lipocalin-1, and lysozyme) and ocular surface mucin in normal and dry eye conditions using high-performance liquid chromatography. After application of saline solution (0.9% sodium chloride) in normal subjects, transient but significant decreases in all tear components were observed. The recovery of protein concentrations took up to 30 minutes and lasted longer when the saline solution was applied more frequently. When applying ophthalmic solutions, a balance between washout and dilutional effects should be considered in addition to the therapeutic effect. Investigation of the effect of diquafosol solution (3%) in normal subjects revealed a significant increase in sialic acid concentration, a marker of ocular mucin, at 5 minutes after application, whereas a significant decrease was observed with saline. This result indicates the accelerated secretion of mucin from ocular tissues induced by diquafosol. A clinical study to determine the efficacy of diquafosol in patients with dry eye revealed improvements in tear breakup time, keratoconjunctival staining scores, and Schirmer test score, accompanied by an increase in sialic acid concentration in tears. Investigating normal and dry eye conditions through tear analysis may clarify the pathophysiology of dry eye conditions and support the efficacy of treatments.
Tanabe, Hiroki C.; Kosaka, Hirotaka; Saito, Daisuke N.; Koike, Takahiko; Hayashi, Masamichi J.; Izuma, Keise; Komeda, Hidetsugu; Ishitobi, Makoto; Omori, Masao; Munesue, Toshio; Okazawa, Hidehiko; Wada, Yuji; Sadato, Norihiro
2012-01-01
Persons with autism spectrum disorders (ASD) are known to have difficulty in eye contact (EC). This may make it difficult for their partners during face to face communication with them. To elucidate the neural substrates of live inter-subject interaction of ASD patients and normal subjects, we conducted hyper-scanning functional MRI with 21 subjects with autistic spectrum disorder (ASD) paired with typically-developed (normal) subjects, and with 19 pairs of normal subjects as a control. Baseline EC was maintained while subjects performed real-time joint-attention task. The task-related effects were modeled out, and inter-individual correlation analysis was performed on the residual time-course data. ASD–Normal pairs were less accurate at detecting gaze direction than Normal–Normal pairs. Performance was impaired both in ASD subjects and in their normal partners. The left occipital pole (OP) activation by gaze processing was reduced in ASD subjects, suggesting that deterioration of eye-cue detection in ASD is related to impairment of early visual processing of gaze. On the other hand, their normal partners showed greater activity in the bilateral occipital cortex and the right prefrontal area, indicating a compensatory workload. Inter-brain coherence in the right IFG that was observed in the Normal-Normal pairs (Saito et al., 2010) during EC diminished in ASD–Normal pairs. Intra-brain functional connectivity between the right IFG and right superior temporal sulcus (STS) in normal subjects paired with ASD subjects was reduced compared with in Normal–Normal pairs. This functional connectivity was positively correlated with performance of the normal partners on the eye-cue detection. Considering the integrative role of the right STS in gaze processing, inter-subject synchronization during EC may be a prerequisite for eye cue detection by the normal partner. PMID:23060772
Koh, Yan Tong; Sanjay, Srinivasan
2013-01-01
The aim of this study was to report the characteristics and ophthalmic manifestations associated with dengue fever (DF) in the 2005-2006 DF epidemic in Singapore. A retrospective case series. Eleven patients (7 males, 4 females) who were 14 to 40 years old (mean age, 27.3 years) with visual complaints occurring 1 to 2 weeks after the onset of DF underwent a complete ophthalmologic examination. The presenting visual acuity (VA) ranged from 6/6 to counting fingers. Five patients had bilateral eye involvement. Ophthalmic findings included retinal hemorrhages (15 eyes), cotton wool spots (15 eyes), retinal pigment epithelium alterations (5 eyes), optic disc swelling (3 eyes), foveolitis (3 eyes), and hyperemia (2 eyes). Impaired color vision was noted in 12 eyes. Visual field defects were noted in 13 eyes; 4 of these eyes were asymptomatic. Fundus fluorescein angiography was done in 9 patients; the findings include choroidal hyperfluorescence (9 eyes), blocked fluorescence (8 eyes), and capillary nonperfusion (1 eye). In 2 eyes, it was normal. Electrophysiology confirmed optic neuropathy in 3 eyes and maculopathy in 1 eye. The follow-up ranged from 12 days to 12 months. The VA at the last follow-up ranged from no light perception to 6/6. Visual field abnormalities were noted in 5 eyes despite a normal VA. Dengue fever is associated with a wide spectrum of ophthalmic manifestations. Rarely, ophthalmic complications in DF can result in permanent visual impairment. Further work can be done to elucidate the relationship between systemic and ocular manifestations of DF.
Unilateral Amblyopia Affects Two Eyes: Fellow Eye Deficits in Amblyopia.
Meier, Kimberly; Giaschi, Deborah
2017-03-01
Unilateral amblyopia is a visual disorder that arises after selective disruption of visual input to one eye during critical periods of development. In the clinic, amblyopia is understood as poor visual acuity in an eye that was deprived of pattern vision early in life. By its nature, however, amblyopia has an adverse effect on the development of a binocular visual system and the interactions between signals from two eyes. Visual functions aside from visual acuity are impacted, and many studies have indicated compromised sensitivity in the fellow eye even though it demonstrates normal visual acuity. While these fellow eye deficits have been noted, no overarching theory has been proposed to describe why and under what conditions the fellow eye is impacted by amblyopia. Here, we consider four explanations that may account for decreased fellow eye sensitivity: the fellow eye is adversely impacted by treatment for amblyopia; the maturation of the fellow eye is delayed by amblyopia; fellow eye sensitivity is impacted for visual functions that rely on binocular cortex; and fellow eye deficits reflect an adaptive mechanism that works to equalize the sensitivity of the two eyes. To evaluate these ideas, we describe five visual functions that are commonly reported to be deficient in the amblyopic eye (hyperacuity, contrast sensitivity, spatial integration, global motion, and motion-defined form), and unify the current evidence for fellow eye deficits. Further research targeted at exploring fellow eye deficits in amblyopia will provide us with a broader understanding of normal visual development and how amblyopia impacts the developing visual system.
Anterior Segment Morphology in Primary Angle Closure Glaucoma using Ultrasound Biomicroscopy
Balakrishna, Nagalla
2017-01-01
Aim To evaluate the configuration of the anterior chamber angle quantitatively and study the morphological changes in the eye with ultrasound biomicroscopy (UBM) in primary angle closure glaucoma (PACG) patients after laser peripheral iridotomy (LPI). Materials and methods A total of 185 eyes of 185 PACG patients post-LPI and 126 eyes of 126 normal subjects were included in this prospective study. All subjects underwent complete ophthalmic evaluation, A-scan biometry, and UBM. The anterior segment and angle parameters were measured quantitatively and compared in both groups using Student’s t-test. Results The PACG patients had shorter axial length, shallower central anterior chamber depth anterior chamber depth (ACD), and anteriorly located lens when compared with normal subjects. Trabecular iris angle (TIA) was significantly narrow (5.73 ± 7.76°) in patients with PACG when compared with normal subjects (23.75 ± 9.38°). The angle opening distance at 500 pm from scleral spur (AOD 500), trabecular-ciliary process distance (TCPD), iris-ciliary process distance (ICPD), and iris-zonule distance (IZD) were significantly shorter in patients with PACG than in normal subjects (p < 0.0001). The iris lens angle (ILA), scleral-iris angle (SIA), and scleral-ciliary process angle (SCPA) were significantly narrower in patients with PACG than in normal subjects (p < 0.0001). The iris-lens contact distance (ILCD) was greater in PACG group than in normal (p = 0.001). Plateau iris was seen in 57/185 (30.8%) of the eyes. Anterior positioned ciliary processes were seen in 130/185 eyes (70.3%) of eyes. Conclusion In PACG patients, persistent apposition angle closure is common even after LPI, which could be due to anterior rotation of ciliary body and plateau iris and overcrowding of anterior segment due to shorter axial length and relative anterior lens position. How to cite this article: Mansoori T, Balakrishna N. Anterior Segment Morphology in Primary Angle Closure Glaucoma using Ultrasound Biomicroscopy. J Curr Glaucoma Pract 2017;11(3):86-91. PMID:29151682
Brief Daily Periods of Unrestricted Vision Can Prevent Form-Deprivation Amblyopia
Wensveen, Janice M.; Harwerth, Ronald S.; Hung, Li-Fang; Ramamirtham, Ramkumar; Kee, Chea-su; Smith, Earl L.
2006-01-01
PURPOSE To characterize how the mechanisms that produce unilateral form-deprivation amblyopia integrate the effects of normal and abnormal vision over time, the effects of brief daily periods of unrestricted vision on the spatial vision losses produced by monocular form deprivation were investigated in infant monkeys. METHODS Beginning at 3 weeks of age, unilateral form deprivation was initiated in 18 infant monkeys by securing a diffuser spectacle lens in front of one eye and a clear plano lens in front of the fellow eye. During the treatment period (18 weeks), three infants wore the diffusers continuously. For the other experimental infants, the diffusers were removed daily and replaced with clear, zero-powered lenses for 1 (n = 5), 2 (n = 6), or 4 (n = 4) hours. Four infants reared with binocular zero-powered lenses and four normally reared monkeys provided control data. RESULTS The degree of amblyopia varied significantly with the daily duration of unrestricted vision. Continuous form deprivation caused severe amblyopia. However, 1 hour of unrestricted vision reduced the degree of amblyopia by 65%, 2 hours reduced the deficits by 90%, and 4 hours preserved near-normal spatial contrast sensitivity. CONCLUSIONS The severely amblyogenic effects of form deprivation in infant primates are substantially reduced by relatively short daily periods of unrestricted vision. The manner in which the mechanisms responsible for amblyopia integrate the effects of normal and abnormal vision over time promotes normal visual development and has important implications for the management of human infants with conditions that potentially cause amblyopia. PMID:16723458
Rebalancing binocular vision in amblyopia.
Ding, Jian; Levi, Dennis M
2014-03-01
Humans with amblyopia have an asymmetry in binocular vision: neural signals from the amblyopic eye are suppressed in the cortex by the fellow eye. The purpose of this study was to develop new models and methods for rebalancing this asymmetric binocular vision by manipulating the contrast and luminance in the two eyes. We measured the perceived phase of a cyclopean sinewave by asking normal and amblyopic observers to indicate the apparent location (phase) of the dark trough in the horizontal cyclopean sine wave relative to a black horizontal reference line, and used the same stimuli to measure perceived contrast by matching the binocular combined contrast to a standard contrast presented to one eye. We varied both the relative contrast and luminance of the two eyes' inputs, in order to rebalance the asymmetric binocular vision. Amblyopic binocular vision becomes more and more asymmetric the higher the stimulus contrast or spatial frequency. Reanalysing our previous data, we found that, at a given spatial frequency, the binocular asymmetry could be described by a log-linear formula with two parameters, one for the maximum asymmetry and one for the rate at which the binocular system becomes asymmetric as the contrast increases. Our new data demonstrates that reducing the dominant eye's mean luminance reduces its suppression of the non-dominant eye, and therefore rebalances the asymmetric binocular vision. While the binocular asymmetry in amblyopic vision can be rebalanced by manipulating the relative contrast or luminance of the two eyes at a given spatial frequency and contrast, it is very difficult or even impossible to rebalance the asymmetry for all visual conditions. Nonetheless, wearing a neutral density filter before the dominant eye (or increasing the mean luminance in the non-dominant eye) may be more beneficial than the traditional method of patching the dominant eye for treating amblyopia. © 2014 The Authors Ophthalmic & Physiological Optics © 2014 The College of Optometrists.
Thompson, Garth J.; Grimmer, Timo; Drzezga, Alexander; Herman, Peter
2016-01-01
Abstract The evolution of functional magnetic resonance imaging to resting state (R-fMRI) allows measurement of changes in brain networks attributed to state changes, such as in neuropsychiatric diseases versus healthy controls. Since these networks are observed by comparing normalized R-fMRI signals, it is difficult to determine the metabolic basis of such group differences. To investigate the metabolic basis of R-fMRI network differences within a normal range, eyes open versus eyes closed in healthy human subjects was used. R-fMRI was recorded simultaneously with fluoro-deoxyglucose positron emission tomography (FDG-PET). Higher baseline FDG was observed in the eyes open state. Variance-based metrics calculated from R-fMRI did not match the baseline shift in FDG. Functional connectivity density (FCD)-based metrics showed a shift similar to the baseline shift of FDG, however, this was lost if R-fMRI “nuisance signals” were regressed before FCD calculation. Average correlation with the mean R-fMRI signal across the whole brain, generally regarded as a “nuisance signal,” also showed a shift similar to the baseline of FDG. Thus, despite lacking a baseline itself, changes in whole-brain correlation may reflect changes in baseline brain metabolism. Conversely, variance-based metrics may remain similar between states due to inherent region-to-region differences overwhelming the differences between normal physiological states. As most previous studies have excluded the spatial means of R-fMRI metrics from their analysis, this work presents the first evidence of a potential R-fMRI biomarker for baseline shifts in quantifiable metabolism between brain states. PMID:27029438
Thompson, Garth J; Riedl, Valentin; Grimmer, Timo; Drzezga, Alexander; Herman, Peter; Hyder, Fahmeed
2016-07-01
The evolution of functional magnetic resonance imaging to resting state (R-fMRI) allows measurement of changes in brain networks attributed to state changes, such as in neuropsychiatric diseases versus healthy controls. Since these networks are observed by comparing normalized R-fMRI signals, it is difficult to determine the metabolic basis of such group differences. To investigate the metabolic basis of R-fMRI network differences within a normal range, eyes open versus eyes closed in healthy human subjects was used. R-fMRI was recorded simultaneously with fluoro-deoxyglucose positron emission tomography (FDG-PET). Higher baseline FDG was observed in the eyes open state. Variance-based metrics calculated from R-fMRI did not match the baseline shift in FDG. Functional connectivity density (FCD)-based metrics showed a shift similar to the baseline shift of FDG, however, this was lost if R-fMRI "nuisance signals" were regressed before FCD calculation. Average correlation with the mean R-fMRI signal across the whole brain, generally regarded as a "nuisance signal," also showed a shift similar to the baseline of FDG. Thus, despite lacking a baseline itself, changes in whole-brain correlation may reflect changes in baseline brain metabolism. Conversely, variance-based metrics may remain similar between states due to inherent region-to-region differences overwhelming the differences between normal physiological states. As most previous studies have excluded the spatial means of R-fMRI metrics from their analysis, this work presents the first evidence of a potential R-fMRI biomarker for baseline shifts in quantifiable metabolism between brain states.
Yamanari, Masahiro; Nagase, Satoko; Fukuda, Shinichi; Ishii, Kotaro; Tanaka, Ryosuke; Yasui, Takeshi; Oshika, Tetsuro; Miura, Masahiro; Yasuno, Yoshiaki
2014-05-01
The relationship between scleral birefringence and biometric parameters of human eyes in vivo is investigated. Scleral birefringence near the limbus of 21 healthy human eyes was measured using polarization-sensitive optical coherence tomography. Spherical equivalent refractive error, axial eye length, and intraocular pressure (IOP) were measured in all subjects. IOP and scleral birefringence of human eyes in vivo was found to have statistically significant correlations (r = -0.63, P = 0.002). The slope of linear regression was -2.4 × 10(-2) deg/μm/mmHg. Neither spherical equivalent refractive error nor axial eye length had significant correlations with scleral birefringence. To evaluate the direct influence of IOP to scleral birefringence, scleral birefringence of 16 ex vivo porcine eyes was measured under controlled IOP of 5-60 mmHg. In these ex vivo porcine eyes, the mean linear regression slope between controlled IOP and scleral birefringence was -9.9 × 10(-4) deg/μm/mmHg. In addition, porcine scleral collagen fibers were observed with second-harmonic-generation (SHG) microscopy. SHG images of porcine sclera, measured on the external surface at the superior side to the cornea, showed highly aligned collagen fibers parallel to the limbus. In conclusion, scleral birefringence of healthy human eyes was correlated with IOP, indicating that the ultrastructure of scleral collagen was correlated with IOP. It remains to show whether scleral collagen ultrastructure of human eyes is affected by IOP as a long-term effect.
Aleman, Tomas S; Ventura, Camila V; Cavalcanti, Milena M; Serrano, Leona W; Traband, Anastasia; Nti, Akosua A; Gois, Adriana L; Bravo-Filho, Vasco; Martins, Thayze T; Nichols, Charles W; Maia, Mauricio; Belfort, Rubens
2017-10-01
A better pathophysiologic understanding of the neurodevelopmental abnormalities observed in neonates exposed in utero to Zika virus (ZIKV) is needed to develop treatments. The retina as an extension of the diencephalon accessible to in vivo microcopy with spectral-domain optical coherence tomography (SD-OCT) can provide an insight into the pathophysiology of congenital Zika syndrome (CZS). To quantify the microstructural changes of the retina in CZS and compare these changes with those of cobalamin C (cblC) deficiency, a disease with potential retinal maldevelopment. This case series included 8 infants with CZS and 8 individuals with cblC deficiency. All patients underwent ophthalmologic evaluation at 2 university teaching hospitals and SD-OCT imaging in at least 1 eye. Patients with cblC deficiency were homozygous or compound heterozygotes for mutations in the methylmalonic aciduria and homocystinuria type C (MMACHC) gene. Data were collected from January 1 to March 17, 2016, for patients with CZS and from May 4, 2015, to April 23, 2016, for patients with cblC deficiency. The SD-OCT cross-sections were segmented using automatic segmentation algorithms embedded in the SD-OCT systems. Each retinal layer thickness was measured at critical eccentricities using the position of the signal peaks and troughs on longitudinal reflectivity profiles. Eight infants with CZS (5 girls and 3 boys; age range, 3-5 months) and 8 patients with cblC deficiency (3 girls and 5 boys; age range, 4 months to 15 years) were included in the analysis. All 8 patients with CZS had foveal abnormalities in the analyzed eyes (8 eyes), including discontinuities of the ellipsoid zone, thinning of the central retina with increased backscatter, and severe structural disorganization, with 3 eyes showing macular pseudocolobomas. Pericentral retina with normal lamination showed a thinned (<30% of normal thickness) ganglion cell layer (GCL) that colocalized in 7 of 8 eyes with a normal photoreceptor layer. The inner nuclear layer was normal or had borderline thinning. The central retinal degeneration was similar to that of cblC deficiency. Congenital Zika syndrome showed a central retinal degeneration with severe GCL loss, borderline inner nuclear layer thinning, and less prominent photoreceptor loss. The findings provide the first, to date, in vivo evidence in humans for possible retinal maldevelopment with a predilection for retinal GCL loss in CZS, consistent with a murine model of the disease and suggestive of in utero depletion of this neuronal population as a consequence of Zika virus infection.
Oberman, Lindsay M; Ramachandran, Vilayanur S
2007-03-01
The mechanism by which humans perceive others differs greatly from how humans perceive inanimate objects. Unlike inanimate objects, humans have the distinct property of being "like me" in the eyes of the observer. This allows us to use the same systems that process knowledge about self-performed actions, self-conceived thoughts, and self-experienced emotions to understand actions, thoughts, and emotions in others. The authors propose that internal simulation mechanisms, such as the mirror neuron system, are necessary for normal development of recognition, imitation, theory of mind, empathy, and language. Additionally, the authors suggest that dysfunctional simulation mechanisms may underlie the social and communicative deficits seen in individuals with autism spectrum disorders.
Bowd, Christopher; Weinreb, Robert N; Balasubramanian, Madhusudhanan; Lee, Intae; Jang, Giljin; Yousefi, Siamak; Zangwill, Linda M; Medeiros, Felipe A; Girkin, Christopher A; Liebmann, Jeffrey M; Goldbaum, Michael H
2014-01-01
The variational Bayesian independent component analysis-mixture model (VIM), an unsupervised machine-learning classifier, was used to automatically separate Matrix Frequency Doubling Technology (FDT) perimetry data into clusters of healthy and glaucomatous eyes, and to identify axes representing statistically independent patterns of defect in the glaucoma clusters. FDT measurements were obtained from 1,190 eyes with normal FDT results and 786 eyes with abnormal FDT results from the UCSD-based Diagnostic Innovations in Glaucoma Study (DIGS) and African Descent and Glaucoma Evaluation Study (ADAGES). For all eyes, VIM input was 52 threshold test points from the 24-2 test pattern, plus age. FDT mean deviation was -1.00 dB (S.D. = 2.80 dB) and -5.57 dB (S.D. = 5.09 dB) in FDT-normal eyes and FDT-abnormal eyes, respectively (p<0.001). VIM identified meaningful clusters of FDT data and positioned a set of statistically independent axes through the mean of each cluster. The optimal VIM model separated the FDT fields into 3 clusters. Cluster N contained primarily normal fields (1109/1190, specificity 93.1%) and clusters G1 and G2 combined, contained primarily abnormal fields (651/786, sensitivity 82.8%). For clusters G1 and G2 the optimal number of axes were 2 and 5, respectively. Patterns automatically generated along axes within the glaucoma clusters were similar to those known to be indicative of glaucoma. Fields located farther from the normal mean on each glaucoma axis showed increasing field defect severity. VIM successfully separated FDT fields from healthy and glaucoma eyes without a priori information about class membership, and identified familiar glaucomatous patterns of loss.
The Initiation of Smooth Pursuit is Delayed in Anisometropic Amblyopia
Raashid, Rana Arham; Liu, Ivy Ziqian; Blakeman, Alan; Goltz, Herbert C.; Wong, Agnes M. F.
2016-01-01
Purpose Several behavioral studies have shown that the reaction times of visually guided movements are slower in people with amblyopia, particularly during amblyopic eye viewing. Here, we tested the hypothesis that the initiation of smooth pursuit eye movements, which are responsible for accurately keeping moving objects on the fovea, is delayed in people with anisometropic amblyopia. Methods Eleven participants with anisometropic amblyopia and 14 visually normal observers were asked to track a step-ramp target moving at ±15°/s horizontally as quickly and as accurately as possible. The experiment was conducted under three viewing conditions: amblyopic/nondominant eye, binocular, and fellow/dominant eye viewing. Outcome measures were smooth pursuit latency, open-loop gain, steady state gain, and catch-up saccade frequency. Results Participants with anisometropic amblyopia initiated smooth pursuit significantly slower during amblyopic eye viewing (206 ± 20 ms) than visually normal observers viewing with their nondominant eye (183 ± 17 ms, P = 0.002). However, mean pursuit latency in the anisometropic amblyopia group during binocular and monocular fellow eye viewing was comparable to the visually normal group. Mean open-loop gain, steady state gain, and catch-up saccade frequency were similar between the two groups, but participants with anisometropic amblyopia exhibited more variable steady state gain (P = 0.045). Conclusions This study provides evidence of temporally delayed smooth pursuit initiation in anisometropic amblyopia. After initiation, the smooth pursuit velocity profile in anisometropic amblyopia participants is similar to visually normal controls. This finding differs from what has been observed previously in participants with strabismic amblyopia who exhibit reduced smooth pursuit velocity gains with more catch-up saccades. PMID:27070109
Crewther, D P; Crewther, S G
2015-09-01
Although the neural locus of strabismic amblyopia has been shown to lie at the first site of binocular integration, first in cat and then in primate, an adequate mechanism is still lacking. Here we hypothesise that increased temporal dispersion of LGN X-cell afferents driven by the deviating eye onto single cortical neurons may provide a neural mechanism for strabismic amblyopia. This idea was investigated via single cell extracellular recordings of 93 X and 50 Y type LGN neurons from strabismic and normal cats. Both X and Y neurons driven by the non-deviating eye showed shorter latencies than those driven by either the strabismic or normal eyes. Also the mean latency difference between X and Y neurons was much greater for the strabismic cells compared with the other two groups. The incidence of lagged X-cells driven by the deviating eye of the strabismic cats was higher than that of LGN X-cells from normal animals. Remarkably, none of the cells recorded from the laminae driven by the non-deviating eye were of the lagged class. A simple computational model was constructed in which a mixture of lagged and non-lagged afferents converge on to single cortical neurons. Model cut-off spatial frequencies to a moving grating stimulus were sensitive to the temporal dispersion of the geniculate afferents. Thus strabismic amblyopia could be viewed as a lack of developmental tuning of geniculate lags for neurons driven by the amblyopic eye. Monocular control of fixation by the non-deviating eye is associated with reduced incidence of lagged neurons, suggesting that in normal vision, lagged neurons might play a role in maintaining binocular connections for cortical neurons. Copyright © 2014 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Besner, Sebastien; Shao, Peng; Scarcelli, Giuliano; Pineda, Roberto; Yun, Seok-Hyun (Andy)
2016-03-01
Keratoconus is a degenerative disorder of the eye characterized by human cornea thinning and morphological change to a more conical shape. Current diagnosis of this disease relies on topographic imaging of the cornea. Early and differential diagnosis is difficult. In keratoconus, mechanical properties are found to be compromised. A clinically available invasive technique capable of measuring the mechanical properties of the cornea is of significant importance for understanding the mechanism of keratoconus development and improve detection and intervention in keratoconus. The capability of Brillouin imaging to detect local longitudinal modulus in human cornea has been demonstrated previously. We report our non-contact, non-invasive, clinically viable Brillouin imaging system engineered to evaluate mechanical properties human cornea in vivo. The system takes advantage of a highly dispersive 2-stage virtually imaged phased array (VIPA) to detect weak Brillouin scattering signal from biological samples. With a 1.5-mW light beam from a 780-nm single-wavelength laser source, the system is able to detect Brillouin frequency shift of a single point in human cornea less than 0.3 second, at a 5μm/30μm lateral/axial resolution. Sensitivity of the system was quantified to be ~ 10 MHz. A-scans at different sample locations on a human cornea with a motorized human interface. We imaged both normal and keratoconic human corneas with this system. Whereas no significantly difference were observed outside keratocnic cones compared with normal cornea, a highly statistically significantly decrease was found in the cone regions.
Immunohistochemical studies in equine recurrent uveitis (ERU).
Romeike, A; Brügmann, M; Drommer, W
1998-11-01
Despite extensive clinical research, the etiology of equine recurrent uveitis (ERU) is still unknown. After an immunologic pathogenesis was established in recurrent uveitis in humans, a similar pathogenic mechanism was assumed to exist in ERU. To investigate whether immunopathologic mechanisms are involved in ERU, 20 eyes of 15 horses with ERU were examined immunohistochemically with a T cell marker, B cell marker, and anti-major histocompatibility complex (MHC) class II antibodies. Twenty-six eyes of 20 horses were used for investigation of MHC class II antigen expression in normal equine eyes. In 18 eyes of 14 horses, the number of T cells in the inflammatory cell population within the uvea was assessed. In 16/18 eyes (89%), the T lymphocyte fraction was > 70%. This cell population was distributed mostly in a diffuse manner throughout the uvea and also within the mantle zone of follicular lymphocytic aggregates. Foci of B lymphocytes could be found within the center of follicular aggregates in three eyes. The expression of MHC class II antigen on resident ocular cells was evaluated in 10 eyes of six horses with ERU. An increase of MHC class II antigen expression in the trabecular meshwork and on the nonpigmented ciliary epithelium was noted as was a deviant expression on proliferating Müller cells and retinal pigment epithelial cells. The predominance of T cells in the inflammatory infiltrates supports the central role of a cell-mediated immune response. Furthermore, the observation of a deviant MHC class II expression on resident ocular cells suggests that aberrant immune regulation may play a role in the pathogenesis of ERU.
Retinal nerve fiber layer reflectance for early glaucoma diagnosis.
Liu, Shuang; Wang, Bingqing; Yin, Biwei; Milner, Thomas E; Markey, Mia K; McKinnon, Stuart J; Rylander, Henry G
2014-01-01
Compare performance of normalized reflectance index (NRI) and retinal nerve fiber layer thickness (RNFLT) parameters determined from optical coherence tomography (OCT) images for glaucoma and glaucoma suspect diagnosis. Seventy-five eyes from 71 human subjects were studied: 33 controls, 24 glaucomatous, and 18 glaucoma-suspects. RNFLT and NRI maps were measured using 2 custom-built OCT systems and the commercial instrument RTVue. Using area under the receiver operating characteristic curve, RNFLT and NRI measured in 7 RNFL locations were analyzed to distinguish between control, glaucomatous, and glaucoma-suspect eyes. The mean NRI of the control group was significantly larger than the means of glaucomatous and glaucoma-suspect groups in most RNFL locations for all 3 OCT systems (P<0.05 for all comparisons). NRI performs significantly better than RNFLT at distinguishing between glaucoma-suspect and control eyes using RTVue OCT (P=0.008). The performances of NRI and RNFLT for classifying glaucoma-suspect versus control eyes were statistically indistinguishable for PS-OCT-EIA (P=0.101) and PS-OCT-DEC (P=0.227). The performances of NRI and RNFLT for classifying glaucomatous versus control eyes were statistically indistinguishable (PS-OCT-EIA: P=0.379; PS-OCT-DEC: P=0.338; RTVue OCT: P=0.877). NRI is a promising measure for distinguishing between glaucoma-suspect and control eyes and may indicate disease in the preperimetric stage. Results of this pilot clinical study warrant a larger study to confirm the diagnostic power of NRI for diagnosing preperimetric glaucoma.
Romano, Paul E
2006-01-01
The HR (prism diopters [PD] per mm of corneal light reflection test [CLRT] asymmetry for strabometry) varies in humans from 14 to 24 PD/mm, but is totally unpredictable. Photo(grammetric) HR calibration in (of) each case facilitates acceptable strabometry precision and accuracy. Take 3 flash photos of the patient with both the preferred eye and then the deviating eye fixating straight ahead and then again with the deviation eye fixing at (+/-5-10 PD) the strabismic angle on a metric rule (stick) one meter away from the camera lens (where 1 cm = 1 PD). On these 3 photos, make four precise measurements of the position of the CLR with reference to the limbus: In the deviating eye fixing straight ahead and fixating at the angle of deviation. Divide the mm difference in location into the change in the angle of fixation to determine the HR for this patient at this angle. Then determine the CLR position in both the deviating eye and the fixing eye in the straight ahead primary position picture. Apply the calculated calibrated HR to the asymmetry of the CLRs in primary position to determine the true strabismic deviation. This imaging method insures accurate Hirschberg CLRT strabometry in each case, determining the deviation in "free space", under conditions of normal binocular viewing, uncontaminated by the artifacts or inaccuracies of other conventional strabometric methods or devices. So performed, the Hirschberg CLRT is the gold standard of strabometry.
Sjöström, A; Abrahamsson, M
1994-04-01
In a previous experimental study on anaesthetized cat it was shown that a short latency (35-40 ms) cortical potential changed polarity due to the presence or absence of a pattern in the flash stimulus. The results suggested one pathway of neuronal activation in the cortex to a pattern that was within the level of resolution and another to patterns that were not. It was implied that a similar difference in impulse transmission to pattern and non-pattern stimuli may be recorded in humans. The present paper describes recordings of the short-latency visual evoked response to varying light flash checkerboard pattern stimuli of high intensity in visually normal and amblyopic children and adults. When stimulating the normal eye a visual evoked response potential with a peak latency between 35 to 40 ms showed a polarity change to patterned compared to non-patterned stimulation. The visual evoked response resolution limit could be correlated to a visual acuity of 0.5 and below. In amblyopic eyes the shift in polarity was recorded at the acuity limit level. The latency of the pattern depending potential was increased in patients with amblyopia compared to normal, but not directly related to amblyopic degree. It is concluded that the short latency, visual evoked response that mainly represents the retino-geniculo-cortical activation may be used to estimate visual resolution below 0.5 in acuity level.(ABSTRACT TRUNCATED AT 250 WORDS)
Quality of corneal lamellar cuts quantified using atomic force microscopy
Ziebarth, Noël M.; Dias, Janice; Hürmeriç, Volkan; Shousha, Mohamed Abou; Yau, Chiyat Ben; Moy, Vincent T.; Culbertson, William; Yoo, Sonia H.
2012-01-01
PURPOSE To quantify the cut quality of lamellar dissections made with the femtosecond laser using atomic force microscopy (AFM). SETTING Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, Florida, USA. DESIGN Experimental study. METHODS Experiments were performed on 3 pairs of human cadaver eyes. The cornea was thinned to physiologic levels by placing the globe, cornea side down, in 25% dextran for 24 hours. The eyes were reinflated to normal pressures by injecting a balanced salt solution into the vitreous cavity. The eyes were placed in a holder, the epithelium was removed, and the eyes were cut with a Visumax femtosecond laser. The energy level was 180 nJ for the right eye and 340 nJ for the left eye of each pair. The cut depths were 200 μm, 300 μm, and 400 μm, with the cut depth maintained for both eyes of each pair. A 12.0 mm trephination was then performed. The anterior portion of the lamellar surface was placed in a balanced salt solution and imaged with AFM. As a control, the posterior surface was placed in 2% formalin and imaged with environmental scanning electron microscopy (SEM). Four quantitative parameters (root-mean-square deviation, average deviation, skewness, kurtosis) were calculated from the AFM images. RESULTS From AFM, the 300 μm low-energy cuts were the smoothest. Similar results were seen qualitatively in the environmental SEM images. CONCLUSION Atomic force microscopy provided quantitative information on the quality of lamellar dissections made using a femtosecond laser, which is useful in optimizing patient outcomes in refractive and lamellar keratoplasty surgeries. PMID:23141078
Candidate genes for panhypopituitarism identified by gene expression profiling
Mortensen, Amanda H.; MacDonald, James W.; Ghosh, Debashis
2011-01-01
Mutations in the transcription factors PROP1 and PIT1 (POU1F1) lead to pituitary hormone deficiency and hypopituitarism in mice and humans. The dysmorphology of developing Prop1 mutant pituitaries readily distinguishes them from those of Pit1 mutants and normal mice. This and other features suggest that Prop1 controls the expression of genes besides Pit1 that are important for pituitary cell migration, survival, and differentiation. To identify genes involved in these processes we used microarray analysis of gene expression to compare pituitary RNA from newborn Prop1 and Pit1 mutants and wild-type littermates. Significant differences in gene expression were noted between each mutant and their normal littermates, as well as between Prop1 and Pit1 mutants. Otx2, a gene critical for normal eye and pituitary development in humans and mice, exhibited elevated expression specifically in Prop1 mutant pituitaries. We report the spatial and temporal regulation of Otx2 in normal mice and Prop1 mutants, and the results suggest Otx2 could influence pituitary development by affecting signaling from the ventral diencephalon and regulation of gene expression in Rathke's pouch. The discovery that Otx2 expression is affected by Prop1 deficiency provides support for our hypothesis that identifying molecular differences in mutants will contribute to understanding the molecular mechanisms that control pituitary organogenesis and lead to human pituitary disease. PMID:21828248
Optical properties of the mouse eye
Geng, Ying; Schery, Lee Anne; Sharma, Robin; Dubra, Alfredo; Ahmad, Kamran; Libby, Richard T.; Williams, David R.
2011-01-01
The Shack-Hartmann wavefront sensor (SHWS) spots upon which ocular aberration measurements depend have poor quality in mice due to light reflected from multiple retinal layers. We have designed and implemented a SHWS that can favor light from a specific retinal layer and measured monochromatic aberrations in 20 eyes from 10 anesthetized C57BL/6J mice. Using this instrument, we show that mice are myopic, not hyperopic as is frequently reported. We have also measured longitudinal chromatic aberration (LCA) of the mouse eye and found that it follows predictions of the water-filled schematic mouse eye. Results indicate that the optical quality of the mouse eye assessed by measurement of its aberrations is remarkably good, better for retinal imaging than the human eye. The dilated mouse eye has a much larger numerical aperture (NA) than that of the dilated human eye (0.5 NA vs. 0.2 NA), but it has a similar amount of root mean square (RMS) higher order aberrations compared to the dilated human eye. These measurements predict that adaptive optics based on this method of wavefront sensing will provide improvements in retinal image quality and potentially two times higher lateral resolution than that in the human eye. PMID:21483598
Cues of Fatigue: Effects of Sleep Deprivation on Facial Appearance
Sundelin, Tina; Lekander, Mats; Kecklund, Göran; Van Someren, Eus J. W.; Olsson, Andreas; Axelsson, John
2013-01-01
Study Objective: To investigate the facial cues by which one recognizes that someone is sleep deprived versus not sleep deprived. Design: Experimental laboratory study. Setting: Karolinska Institutet, Stockholm, Sweden. Participants: Forty observers (20 women, mean age 25 ± 5 y) rated 20 facial photographs with respect to fatigue, 10 facial cues, and sadness. The stimulus material consisted of 10 individuals (five women) photographed at 14:30 after normal sleep and after 31 h of sleep deprivation following a night with 5 h of sleep. Measurements: Ratings of fatigue, fatigue-related cues, and sadness in facial photographs. Results: The faces of sleep deprived individuals were perceived as having more hanging eyelids, redder eyes, more swollen eyes, darker circles under the eyes, paler skin, more wrinkles/fine lines, and more droopy corners of the mouth (effects ranging from b = +3 ± 1 to b = +15 ± 1 mm on 100-mm visual analog scales, P < 0.01). The ratings of fatigue were related to glazed eyes and to all the cues affected by sleep deprivation (P < 0.01). Ratings of rash/eczema or tense lips were not significantly affected by sleep deprivation, nor associated with judgements of fatigue. In addition, sleep-deprived individuals looked sadder than after normal sleep, and sadness was related to looking fatigued (P < 0.01). Conclusions: The results show that sleep deprivation affects features relating to the eyes, mouth, and skin, and that these features function as cues of sleep loss to other people. Because these facial regions are important in the communication between humans, facial cues of sleep deprivation and fatigue may carry social consequences for the sleep deprived individual in everyday life. Citation: Sundelin T; Lekander M; Kecklund G; Van Someren EJW; Olsson A; Axelsson J. Cues of fatigue: effects of sleep deprivation on facial appearance. SLEEP 2013;36(9):1355-1360. PMID:23997369
Craniofacial abnormalities in homozygous Small eye (Sey/Sey) embryos and newborn mice.
Kaufman, M H; Chang, H H; Shaw, J P
1995-06-01
The Small eye (Sey) gene in the mouse is lethal in the homozygous state. It is located on chromosome 2, is a mutation in the Pax-6 gene, and is genetically homologous with the human aniridia 2 (AN2) gene mutation. Numerous studies over the last few years, using genetic and molecular biological approaches, have investigated both the location of the gene as well as its possible mode of action. In the homozygous state, the primary defect appears to be limited to the failure of differentiation of the presumptive lens and nasal placodes. Such mice therefore display a characteristic phenotype; they possess neither eyes nor any nasal derivatives. Their heterozygous (Sey/+) and normal (+/+) littermates may be distinguished before birth only by a detailed examination of their eyes. Few detailed morphological/histological studies have been undertaken to date in the Sey/Sey embryos and newborn, and in the present study we describe a variety of craniofacial abnormalities that have not previously been reported. We observed, with one exception, delayed closure of the palate, and the presence in 80% of mice of an abnormal complement of upper incisor teeth, so that 35% possessed 1 supernumerary tooth while 45% possessed 2 supernumerary teeth. In these mice, a total of either 3 or 4, rather than the normal complement of 2, upper incisor teeth were present. Possibly the most unexpected finding, however, was the presence of a median cartilaginous rod-like structure which protruded between the 2 maxillae to give the Alizarin red S and Alcian blue-stained 'cleared' skulls of the newborn mice a characteristic 'unicorn-like' appearance. While this structure appeared to be a rostral extension of the chondrocranium, its exact derivation is unclear.
Peripheral Vision Can Influence Eye Growth and Refractive Development in Infant Monkeys
Smith, Earl L.; Kee, Chea-su; Ramamirtham, Ramkumar; Qiao-Grider, Ying; Hung, Li-Fang
2006-01-01
PURPOSE Given the prominence of central vision in humans, it has been assumed that visual signals from the fovea dominate emmetropization. The purpose of this study was to examine the impact of peripheral vision on emmetropization. METHODS Bilateral, peripheral form deprivation was produced in 12 infant monkeys by rearing them with diffusers that had either 4- or 8-mm apertures centered on the pupils of each eye, to allow 24° or 37° of unrestricted central vision, respectively. At the end of the lens-rearing period, an argon laser was used to ablate the fovea in one eye of each of seven monkeys. Subsequently, all the animals were allowed unrestricted vision. Refractive error and axial dimensions were measured along the pupillary axis by retinoscopy and A-scan ultrasonography, respectively. Control data were obtained from 21 normal monkeys and 3 infants reared with binocular plano lenses. RESULTS Nine of the 12 treated monkeys had refractive errors that fell outside the 10th- and 90th-percentile limits for the age-matched control subjects, and the average refractive error for the treated animals was more variable and significantly less hyperopic/more myopic (+0.03 ± 2.39 D vs. +2.39 ± 0.92 D). The refractive changes were symmetric in the two eyes of a given animal and axial in nature. After lens removal, all the treated monkeys recovered from the induced refractive errors. No interocular differences in the recovery process were observed in the animals with monocular foveal lesions. CONCLUSIONS On the one hand, the peripheral retina can contribute to emmetropizing responses and to ametropias produced by an abnormal visual experience. On the other hand, unrestricted central vision is not sufficient to ensure normal refractive development, and the fovea is not essential for emmetropizing responses. PMID:16249469
Comparison of RNFL thickness and RPE-normalized RNFL attenuation coefficient for glaucoma diagnosis
NASA Astrophysics Data System (ADS)
Vermeer, K. A.; van der Schoot, J.; Lemij, H. G.; de Boer, J. F.
2013-03-01
Recently, a method to determine the retinal nerve fiber layer (RNFL) attenuation coefficient, based on normalization on the retinal pigment epithelium, was introduced. In contrast to conventional RNFL thickness measures, this novel measure represents a scattering property of the RNFL tissue. In this paper, we compare the RNFL thickness and the RNFL attenuation coefficient on 10 normal and 8 glaucomatous eyes by analyzing the correlation coefficient and the receiver operator curves (ROCs). The thickness and attenuation coefficient showed moderate correlation (r=0.82). Smaller correlation coefficients were found within normal (r=0.55) and glaucomatous (r=0.48) eyes. The full separation between normal and glaucomatous eyes based on the RNFL attenuation coefficient yielded an area under the ROC (AROC) of 1.0. The AROC for the RNFL thickness was 0.9875. No statistically significant difference between the two measures was found by comparing the AROC. RNFL attenuation coefficients may thus replace current RNFL thickness measurements or be combined with it to improve glaucoma diagnosis.
Herwig, M C; Müller, A M; Holz, F G; Loeffler, K U
2010-11-01
Information on the evaluation of prenatal ocular findings is sparse. This article provides an overview of the morphology in a cohort of human fetal eyes, with particular emphasis on interesting findings. The study investigated 216 eyes from 115 human fetuses. The majority of fetal eyes presented with a regular phenotype. Rarely, unexpected findings were discovered in fetuses with or without systemic malformations. Routine evaluation of fetal eyes reveals-albeit rarely-new aspects providing further knowledge and occasionally enabling the exact classification of syndromes.
Goodarzi, Naser; Dabbaghi, Parviz; Valipour, Habib; Vafadari, Behnam
2015-04-01
Based on the previous studies, we know that the hemispheric lateralization defects, increase the probability of psychological disorders. We also know that dominant limb is controlled by dominant hemisphere and limb preference is used as an indicator for hemisphere dominance. In this study we attempted to explore the hemispheric dominance by the use of three limbs (hand, foot and eye). We performed this survey on two samples, psychiatric patients compared with normal population. For this purpose, knowing that the organ dominance is stabilized in adolescence, and age has no effect on the people above 15, we used 48 high school girls and 65 boys as the final samples of normal population. The patient group included 57 male and 26 female who were chronic psychiatric patients. The result shows that left-eye dominance is more in patients than the normal group (P=0.000) but the handedness and footedness differences are not significance. In psychotic, bipolar and depressive disorders, eye dominance had significant difference (P=0.018). But this is not true about hand and foot dominance. Our findings proved that generally in psychiatric patients, left-eye dominance is more common, left-eye dominance is also more in psychotic and depressive disorders. It is less common in bipolar disorders.
Zhou, Xiangtian; Ji, Fengtao; An, Jianhong; Zhao, Fuxin; Shi, Fanjun; Huang, Furong; Li, Yuan; Jiao, Shiming; Yan, Dongsheng; Chen, Xiaoyan; Chen, JiangFan
2012-01-01
Purpose To investigate whether myopia development is associated with changes of scleral DNA methylation in cytosine-phosphate-guanine (CpG) sites in the collagen 1A1 (COL1A1) promoter and messenger RNA (mRNA) levels following murine form deprivation myopia. Methods Fifty-seven C57BL/6 mice (postnatal day 23) were randomly assigned to four groups: (1) monocular form deprivation (MD) in which a diffuser lens was placed over one eye for 28 days; (2) normal controls without MD; (3) MD recovery in which the diffuser lens was removed for seven days; and (4) MD recovery normal controls. The DNA methylation pattern in COL1A1 promoter and exon 1 was determined by bisulfite DNA sequencing, and the COL1A1 mRNA level in sclera was determined by quantitative PCR. Results MD was found to induce myopia in the treated eyes. Six CpG sites in the promoter and exon 1 region of COL1A1 were methylated with significantly higher frequency in the treated eyes than normal control eyes (p<0.05), with CpG island methylation in MD-contralateral eyes being intermediate. Consistent with the CpG methylation, scleral COL1A1 mRNA was reduced by 57% in the MD-treated eyes compared to normal controls (p<0.05). After seven days of MD recovery, CpG methylation was significantly reduced (p=0.01). The methylation patterns returned to near normal level in five CpG sites, but the sixth was hypomethylated compared to normal controls. Conclusions In parallel with the development of myopia and the reduced COL1A1 mRNA, the frequency of methylation in CpG sites of the COL1A1 promoter/exon 1 increased during MD and returned to near normal during recovery. Thus, hypermethylation of CpG sites in the promoter/exon 1 of COL1A1 may underlie reduced collagen synthesis at the transcriptional level in myopic scleras. PMID:22690110
Xu, Zhe; Peng, Mei; Jiang, Jun; Yang, Chun; Zhu, Weigen; Lu, Fan; Shen, Meixiao
2016-02-01
To measure the repeatability and reproducibility of Pentacam HR system thickness maps for the entire cornea in normal, post-laser in situ keratomileusis (post-LASIK), and keratoconus (KC) eyes. Reliability study. Sixty normal subjects (60 eyes), 30 post-LASIK subjects (60 eyes), and 14 KC patients (27 eyes) were imaged with the Pentacam HR system by 2 well-trained operators. For pachymetry the cornea was divided into 4 zones: a central zone (2-mm diameter) and concentric pericentral zone (2-5 mm), transitional zone (5-7 mm), and peripheral zone (7-10 mm). The 3 concentric zones were subdivided into 8 sectors. Intraobserver repeatability and interobserver reproducibility of entire corneal thickness maps were tested by the repeatability and reproducibility coefficients, intraclass correlation coefficients, coefficient of variation, and 95% limits of agreement. From central to peripheral zones, the precision of corneal thickness measurements became gradually smaller. Central zone repeatability and reproducibility were the best in the normal, post-LASIK, and KC groups. The peripheral superior sectors showed poorer repeatability and reproducibility for all subjects. The intraobserver repeatability and interobserver reproducibility for all zones were ≤19.3 μm, ≤22.1 μm, and ≤20.7 μm, in the normal, post-LASIK, and KC groups, respectively. The intraobserver and interobserver coefficients of variation for all zones were ≤1.3%, ≤1.6%, and ≤1.6% for all 3 groups. Pentacam HR system pachymetry of the entire cornea provided good precision in normal, post-LASIK, and KC corneas. Thickness measurements in the peripheral cornea should be interpreted with caution in abnormal corneas after surgery or with diseases. Copyright © 2016 Elsevier Inc. All rights reserved.
Modifiers of radiation effects in the eye
NASA Astrophysics Data System (ADS)
Kleiman, Norman J.; Stewart, Fiona A.; Hall, Eric J.
2017-11-01
World events, including the threat of radiological terrorism and the fear of nuclear accidents, have highlighted an urgent need to develop medical countermeasures to prevent or reduce radiation injury. Similarly, plans for manned spaceflight to a near-Earth asteroid or journey to Mars raise serious concerns about long-term effects of space radiation on human health and the availability of suitable therapeutic interventions. At the same time, the need to protect normal tissue from the deleterious effects of radiotherapy has driven considerable research into the design of effective radioprotectors. For more than 70 years, animal models of radiation cataract have been utilized to test the short and long-term efficacy of various radiation countermeasures. While some compounds, most notably the Walter Reed (WR) class of radioprotectors, have reported limited effectiveness when given before exposure to low-LET radiation, the human toxicity of these molecules at effective doses limits their usefulness. Furthermore, while there has been considerable testing of eye responses to X- and gamma irradiation, there is limited information about using such models to limit the injurious effects of heavy ions and neutrons on eye tissue. A new class of radioprotector molecules, including the sulfhydryl compound PrC-210, are reported to be effective at much lower doses and with far less side effects. Their ability to modify ocular radiation damage has not yet been examined. The ability to non-invasively measure sensitive, radiation-induced ocular changes over long periods of time makes eye models an attractive option to test the radioprotective and radiation mitigating abilities of new novel compounds.
Detection and description of non-linear interdependence in normal multichannel human EEG data.
Breakspear, M; Terry, J R
2002-05-01
This study examines human scalp electroencephalographic (EEG) data for evidence of non-linear interdependence between posterior channels. The spectral and phase properties of those epochs of EEG exhibiting non-linear interdependence are studied. Scalp EEG data was collected from 40 healthy subjects. A technique for the detection of non-linear interdependence was applied to 2.048 s segments of posterior bipolar electrode data. Amplitude-adjusted phase-randomized surrogate data was used to statistically determine which EEG epochs exhibited non-linear interdependence. Statistically significant evidence of non-linear interactions were evident in 2.9% (eyes open) to 4.8% (eyes closed) of the epochs. In the eyes-open recordings, these epochs exhibited a peak in the spectral and cross-spectral density functions at about 10 Hz. Two types of EEG epochs are evident in the eyes-closed recordings; one type exhibits a peak in the spectral density and cross-spectrum at 8 Hz. The other type has increased spectral and cross-spectral power across faster frequencies. Epochs identified as exhibiting non-linear interdependence display a tendency towards phase interdependencies across and between a broad range of frequencies. Non-linear interdependence is detectable in a small number of multichannel EEG epochs, and makes a contribution to the alpha rhythm. Non-linear interdependence produces spatially distributed activity that exhibits phase synchronization between oscillations present at different frequencies. The possible physiological significance of these findings are discussed with reference to the dynamical properties of neural systems and the role of synchronous activity in the neocortex.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Polsdofer, E; Crilly, R
Purpose: This study investigates the effect of eye size and eccentricity on doses to critical tissues by simulating doses in the Plaque Simulator (v. 6.3.1) software. Present OHSU plaque brachytherapy treatment focuses on delivering radiation to the tumor measured with ocular ultrasound plus a small margin and assumes the orbit has the dimensions of a “standard eye.” Accurately modeling the dimensions of the orbit requires a high resolution ocular CT. This study quantifies how standard differences in equatorial diameters and eccentricity affect calculated doses to critical structures in order to query the justification of the additional CT scan to themore » treatment planning process. Methods: Tumors of 10 mm × 10 mm × 5 mm were modeled at the 12:00:00 hour with a latitude of 45 degrees. Right eyes were modeled at a number of equatorial diameters from 17.5 to 28 mm for each of the standard non-notched COMS plaques with silastic inserts. The COMS plaques were fully loaded with uniform activity, centered on the tumor, and prescribed to a common tumor dose (85 Gy/100 hours). Variations in the calculated doses to normal structures were examined to see if the changes were significant. Results: The calculated dose to normal structures show a marked dependence on eye geometry. This is exemplified by fovea dose which more than doubled in the smaller eyes and nearly halved in the larger model. Additional significant dependence was found in plaque size on the calculated dose in spite of all plaques giving the same dose to the prescription point. Conclusion: The variation in dose with eye dimension fully justifies the addition of a high resolution ocular CT to the planning technique. Additional attention must be made to plaque size beyond simply covering the tumor when considering normal tissue dose.« less
Roberts, Cynthia J; Mahmoud, Ashraf M; Bons, Jeffrey P; Hossain, Arif; Elsheikh, Ahmed; Vinciguerra, Riccardo; Vinciguerra, Paolo; Ambrósio, Renato
2017-04-01
To investigate two new stiffness parameters and their relationships with the dynamic corneal response (DCR) parameters and compare normal and keratoconic eyes. Stiffness parameters are defined as Resultant Pressure at inward applanation (A1) divided by corneal displacement. Stiffness parameter A1 uses displacement between the undeformed cornea and A1 and stiffness parameter highest concavity (HC) uses displacement from A1 to maximum deflection during HC. The spatial and temporal profiles of the Corvis ST (Oculus Optikgeräte, Wetzlar, Germany) air puff were characterized using hot wire anemometry. An adjusted air pressure impinging on the cornea at A1 (adjAP1) and an algorithm to biomechanically correct intraocular pressure based on finite element modelling (bIOP) were used for Resultant Pressure calculation (adjAP1 - bIOP). Linear regression analyses between DCR parameters and stiffness parameters were performed on a retrospective dataset of 180 keratoconic eyes and 482 normal eyes. DCR parameters from a subset of 158 eyes of 158 patients in each group were matched for bIOP and compared using t tests. A P value of less than .05 was considered statistically significant. All DCR parameters evaluated showed significant differences between normal and keratoconic eyes, except peak distance. Keratoconic eyes had lower stiffness parameter values, thinner pachymetry, shorter applanation lengths, greater absolute values of applanation velocities, earlier A1 times and later second applanation times, greater HC deformation amplitudes and HC deflection amplitudes, and lower HC radius of concave curvature (greater concave curvature). Most DCR parameters showed a significant relationship with both stiffness parameters in both groups. Keratoconic eyes demonstrated less resistance to deformation than normal eyes with similar IOP. The stiffness parameters may be useful in future biomechanical studies as potential biomarkers. [J Refract Surg. 2017;33(4):266-273.]. Copyright 2017, SLACK Incorporated.
Ventura, Bruna V; Wang, Li; Ali, Shazia F; Koch, Douglas D; Weikert, Mitchell P
2015-08-01
To evaluate and compare the performance of a point-source color light-emitting diode (LED)-based topographer (color-LED) in measuring anterior corneal power and aberrations with that of a Placido-disk topographer and a combined Placido and dual Scheimpflug device. Cullen Eye Institute, Baylor College of Medicine, Houston, Texas USA. Retrospective observational case series. Normal eyes and post-refractive-surgery eyes were consecutively measured using color-LED, Placido, and dual-Scheimpflug devices. The main outcome measures were anterior corneal power, astigmatism, and higher-order aberrations (HOAs) (6.0 mm pupil), which were compared using the t test. There were no statistically significant differences in corneal power measurements in normal and post-refractive surgery eyes and in astigmatism magnitude in post-refractive surgery eyes between the color-LED device and Placido or dual Scheimpflug devices (all P > .05). In normal eyes, there were no statistically significant differences in 3rd-order coma and 4th-order spherical aberration between the color-LED and Placido devices and in HOA root mean square, 3rd-order coma, 3rd-order trefoil, 4th-order spherical aberration, and 4th-order secondary astigmatism between the color-LED and dual Scheimpflug devices (all P > .05). In post-refractive surgery eyes, the color-LED device agreed with the Placido and dual-Scheimpflug devices regarding 3rd-order coma and 4th-order spherical aberration (all P > .05). In normal and post-refractive surgery eyes, all 3 devices were comparable with respect to corneal power. The agreement in corneal aberrations varied. Drs. Wang, Koch, and Weikert are consultants to Ziemer Ophthalmic Systems AG. Dr. Koch is a consultant to Abbott Medical Optics, Inc., Alcon Surgical, Inc., and i-Optics Corp. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Mean Posterior Corneal Power and Astigmatism in Normal Versus Keratoconic Eyes.
Feizi, Sepehr; Delfazayebaher, Siamak; Javadi, Mohammad Ali; Karimian, Farid; Ownagh, Vahid; Sadeghpour, Fatemeh
2018-01-01
To compare mean posterior corneal power and astigmatism in normal versus keratoconus affected eyes and determine the optimal cut-off points to maximize sensitivity and specificity in discriminating keratoconus from normal corneas. A total of 204 normal eyes and 142 keratoconus affected eyes were enrolled in this prospective comparative study. Mean posterior corneal power and astigmatism were measured using a dual Scheimpflug camera. Correlation coefficients were calculated to assess the relationship between the magnitudes of keratometric and posterior corneal astigmatism in the study groups. Receiver operating characteristic curves were used to compare the sensitivity and specificity of the measured parameters and to identify the optimal cut-off points for discriminating keratoconus from normal corneas. The mean posterior corneal power was -6.29 ± 0.20 D in the normal group and -7.77 ± 0.87 D in the keratoconus group ( P < 0.001). The mean magnitudes of the posterior corneal astigmatisms were -0.32 ± 0.15 D and -0.94 ± 0.39 D in the normal and keratoconus groups, respectively ( P < 0.001). Significant correlations were found between the magnitudes of keratometric and posterior corneal astigmatism in the normal (r=-0.76, P < 0.001) and keratoconus (r=-0.72, P < 0.001) groups. The mean posterior corneal power and astigmatism were highly reliable characteristics that distinguished keratoconus from normal corneas (area under the curve, 0.99 and 0.95, respectively). The optimal cut-off points of mean posterior corneal power and astigmatism were -6.70 D and -0.54 D, respectively. Mean posterior corneal power and astigmatism measured using a Galilei analyzer camera might have potential in diagnosing keratoconus. The cut-off points provided can be used for keratoconus screening.
Yang, Hongli; Downs, J. Crawford; Sigal, Ian A.; Roberts, Michael D.; Thompson, Hillary; Burgoyne, Claude F.
2010-01-01
Purpose To characterize optic nerve head (ONH) connective tissue deformation following acute (15 or 30 minutes) intraocular pressure (IOP) elevation within six adult normal monkeys using 3-D histomorphometry. Methods Trephinated ONH and peripapillary sclera from both eyes of six monkeys, each perfusion fixed with one eye at IOP 10 mmHg and the other at IOP 30 or 45 mmHg by anterior chamber manometer were serial sectioned, 3-D reconstructed, 3-D delineated and quantified using standard parameters. For each monkey, inter-eye differences (high IOP eye minus IOP 10 eye) for each parameter were calculated and compared by ANOVA and EPIDmax both overall and regionally. EPIDmax deformations for each parameter were defined to be those statistically significant differences that exceeded the maximum physiologic inter-eye difference within six bilaterally normal monkeys of a previous report. Results Regional EPIDmax laminar thinning, posterior bowing of the peripapillary sclera, thinning and expansion of the scleral canal were present in most high IOP eyes and were colocalized in those demonstrating the most deformation. Laminar deformation was minimal and not only posterior but in some cases anterior in the high IOP eyes. No increase in deformation was seen in the IOP-45 versus the IOP-30 eyes. Conclusion ONH connective tissue alterations following acute IOP elevation involve regional thinning, stretching and deformation of the lamina cribrosa and peripapillary sclera which are minimal to modest in magnitude. The time-dependent character of these alterations, as well as their compressive, expansile, and shear effects on the contained axons, astrocytes, laminar and posterior ciliary circulations remain to be determined. PMID:19628739
Brown, Jacob D; Dutta, Sunit; Bharti, Kapil; Bonner, Robert F; Munson, Peter J; Dawid, Igor B; Akhtar, Amana L; Onojafe, Ighovie F; Alur, Ramakrishna P; Gross, Jeffrey M; Hejtmancik, J Fielding; Jiao, Xiaodong; Chan, Wai-Yee; Brooks, Brian P
2009-02-03
The gene networks underlying closure of the optic fissure during vertebrate eye development are poorly understood. Here, we profile global gene expression during optic fissure closure using laser capture microdissected (LCM) tissue from the margins of the fissure. From these data, we identify a unique role for the C(2)H(2) zinc finger proteins Nlz1 and Nlz2 in normal fissure closure. Gene knockdown of nlz1 and/or nlz2 in zebrafish leads to a failure of the optic fissure to close, a phenotype which closely resembles that seen in human uveal coloboma. We also identify misregulation of pax2 in the developing eye of morphant fish, suggesting that Nlz1 and Nlz2 act upstream of the Pax2 pathway in directing proper closure of the optic fissure.
Perinuclear lens retrodots: a role for ascorbate in cataractogenesis.
Bron, A J; Brown, N A
1987-01-01
Lens retrodots are round, oblong, or oval features in the perinuclear zone of the adult lens after the fifth decade of life and associated with cataract. Retrodots were found in 47 out of 121 eyes with cataract (39%) in the present series. They show birefringence in vivo and in vitro, and chemical studies suggest that they contain calcium oxalate. It is proposed that ascorbic acid, which is abundant in the normal human lens, is the most likely source for this oxalate. Ascorbic acid is thought to have a protective role against oxidative stress in the lens and other parts of the eye, and its level is known to be reduced in senile cataract. The presence of the retrodots may identify lenses which have been exposed to oxidative stress and are less capable of resisting oxidative damage. Images PMID:3828268
Regional cerebral glucose metabolic rate in human sleep assessed by positron emission tomography
DOE Office of Scientific and Technical Information (OSTI.GOV)
Buchsbaum, M.S.; Wu, J.; Hazlett, E.
The cerebral metabolic rate of glucose was measured during nighttime sleep in 36 normal volunteers using positron emission tomography and fluorine-18-labeled 2-deoxyglucose (FDG). In comparison to waking controls, subjects given FDG during non-rapid eye movement (NREM) sleep showed about a 23% reduction in metabolic rate across the entire brain. This decrease was greater for the frontal than temporal or occipital lobes, and greater for basal ganglia and thalamus than cortex. Subjects in rapid eye movement (REM) sleep tended to have higher cortical metabolic rates than walking subjects. The cingulate gyrus was the only cortical structure to show a significant increasemore » in glucose metabolic rate in REM sleep in comparison to waking. The basal ganglia were relatively more active on the right in REM sleep and symmetrical in NREM sleep.« less
Kondo, Mineo; Ito, Yasuki; Miyata, Kentaro; Kondo, Nagako; Ishikawa, Kohei; Terasaki, Hiroko
2006-01-01
To investigate the effect of shorter axial length on the laser spot size and laser energy during photodynamic therapy (PDT) in monkeys. Experimental study with four rhesus monkeys. PDT was performed on the normal retina of monkeys whose ocular axial lengths are shorter (19.55 to 20.25 mm) than that of humans. After the PDT, the eyes were enucleated, and the diameter of the irradiated laser spot was measured with a microcaliper. The area of actual laser spot was only 0.56 to 0.61 times of the planned area, which indicated that the laser energy/area was 1.64 to 1.78 times more intense than planned initially. These results are the in vivo demonstration that the diameter of PDT laser spot is smaller for eyes with shorter axial lengths.
Koh, Shizuka; Tung, Cynthia; Aquavella, James; Yadav, Rahul; Zavislan, James; Yoon, Geunyoung
2010-07-01
PURPOSE. To investigate tear film dynamics using simultaneous measurements of ocular aberrations and lower tear meniscus. METHODS. Simultaneous measurements of wavefront aberration and lower tear meniscus were performed for 11 normal eyes and 7 eyes with short tear film break-up time (SBUT) dry eye, with a tear film break-up time shorter than 5 seconds, using a wavefront sensor and an anterior segment optical coherence tomography (OCT). During the measurement, the subjects were instructed to blink every 6 seconds for a total of 30 seconds. From the measured aberration, root mean square (RMS) wavefront error and volume modulation transfer function (vMTF) induced by changes in tear film dynamics were calculated for a 5-mm pupil. Lower tear meniscus height (TMH) and area (TMA) were estimated from the cross-sectional OCT images of lower tear meniscus. RESULTS. There was a positive correlation between RMS and tear meniscus dimensions and a negative correlation between vMTF and tear meniscus in both groups. There were moderate negative correlations between the postblink initial RMS change and baseline TMH (R = -0.61) and TMA (R = -0.54) in SBUT dry eyes that were stronger than in normal eyes (R = -0.37, R = -0.38). CONCLUSIONS. Tear meniscus dimensions increase with RMS over time, and tear quantity before blink has a significant role in maintaining initial optical integrity, especially in SBUT dry eye. Simultaneous measurement of optical quality and tear meniscus has the potential to improve understanding of tear stability in normal eyes and dry eyes.
Koh, Shizuka; Ikeda, Chikako; Fujimoto, Hisataka; Oie, Yoshinori; Soma, Takeshi; Maeda, Naoyuki; Nishida, Kohji
2016-07-01
To noninvasively investigate regional differences in tear film stability and meibomian glands in patients with aqueous-deficient dry eye. Forty-nine dry eyes and 31 normal eyes were analyzed. A corneal topographer with a tear film scanning function was used for noninvasive tear film break-up time (NI-TFBUT) measurements and meibomian gland observations. The NI-TFBUT values and location of the first tear film break-up point were recorded in four quadrants. Meibomian gland loss was graded for each eyelid using meiboscores. Lid margin abnormality was scored from zero to four according to the number of existing abnormalities. The NI-TFBUT values and meiboscores were compared between two groups, and regional differences in NI-TFBUT values and meiboscores were analyzed. Also, the correlation between the NI-TFBUT and ocular surface examination results were investigated. The NI-TFBUT values and meiboscores were significantly lower and higher, respectively, for the dry eye group than for the normal group. In the dry eye group, the occurrence rate for first tear film break-up was the highest in the inferior nasal quadrant, and the mean meiboscore was significantly higher for the upper eyelids than for the lower eyelids. The NI-TFBUT and lid margin abnormality scores showed a weak negative correlation, and the NI-TFBUT values and meiboscores showed no correlation. Compared to normal eyes, aqueous-deficient dry eyes show significant regional differences in tear film stability and meibomian glands. Considering these regional differences, the overall observation of the ocular surface, including both upper and lower eyelids, will aid clinicians in understanding this condition better.
Gür Güngör, Sirel; Akman, Ahmet; Sarıgül Sezenöz, Almila; Tanrıaşıkı, Gülşah
2016-12-01
The presence of retinal nerve fiber layer (RNFL) split bundles was recently described in normal eyes scanned using scanning laser polarimetry and by histologic studies. Split bundles may resemble RNFL loss in healthy eyes. The aim of our study was to determine the prevalence of nerve fiber layer split bundles in healthy people. We imaged 718 eyes of 359 healthy persons with the spectral domain optical coherence tomography in this cross-sectional study. All eyes had intraocular pressure of 21 mmHg or less, normal appearance of the optic nerve head, and normal visual fields (Humphrey Field Analyzer 24-2 full threshold program). In our study, a bundle was defined as 'split' when there is localized defect not resembling a wedge defect in the RNFL deviation map with a symmetrically divided RNFL appearance on the RNFL thickness map. The classification was performed by two independent observers who used an identical set of reference examples to standardize the classification. Inter-observer consensus was reached in all cases. Bilateral superior split bundles were seen in 19 cases (5.29%) and unilateral superior split was observed in 15 cases (4.16%). In 325 cases (90.52%) there was no split bundle. Split nerve fiber layer bundles, in contrast to single nerve fiber layer bundles, are not common findings in healthy eyes. In eyes with normal optic disc appearance, especially when a superior RNFL defect is observed in RNFL deviation map, the RNLF thickness map and graphs should also be examined for split nerve fiber layer bundles.
Corneal status in primary angle-closure glaucoma with a history of acute attack.
Chen, Mei-Ju; Liu, Catherine Jui-Ling; Cheng, Ching-Yu; Lee, Shui-Mei
2012-01-01
The corneal status of patients with primary angle-closure glaucoma (PACG) with a history of acute attack was investigated. This cross-sectional study included 40 eyes of PACG patients with an earlier documented symptomatic acute angle-closure attack (aPACG), 40 uninvolved fellow eyes of aPACG patients (fPACG), 44 eyes of chronic PACG patients without such a history (cPACG), and 50 eyes of age-matched normal participants. All glaucoma patients had patent peripheral iridotomies with adequate intraocular pressure control. The examinations and recorded parameters included visual acuity, intraocular pressure, gonioscopy, vertical cup-to-disc ratio, specular microscopy, central corneal pachymetry, refraction, corneal curvature radius, anterior chamber depth, axial length, and lens thickness measurements, and the presenting intraocular pressure and the duration of acute angle-closure attack for aPACG eyes. The mean endothelial cell density was 2271±80 cells/mm(2) in aPACG, 2458±79 cells/mm(2) in fPACG, 2379±50 cells/mm(2) in cPACG, and 2559±45 cells/mm(2) in controls. The aPACG eyes had significantly lower endothelial cell density compared with normal eyes (P=0.002). There was no significant difference in endothelial cell density of aPACG eyes compared with fPACG or cPACG eyes. Multivariate analysis showed the duration of the acute attack was the only factor independently associated with corneal endothelial density of aPACG eyes. The mean central corneal thickness of aPACG (549±32 μm) did not differ significantly from control eyes (552±27 μm), cPACG (557±32 μm), and fPACG (553±31 μm) (P=0.911, 0.274, and 0.725, respectively). Corneal curvature radius of aPACG eyes was not significantly different from that of the comparison groups (all P>0.05). Corneal endothelial cell density was significantly reduced in aPACG eyes compared with normal eyes. No significant difference in endothelial cell density of aPACG eyes was noted when compared with fPACG or cPACG eyes. Corneal endothelial cell density was negatively associated with the duration of the acute attack, but was not associated with demographic and biometric characteristics. Central corneal thickness and corneal curvature radius were not associated with an earlier acute angle-closure attack.
Distinct Circuits for Recovery of Eye Dominance and Acuity in Murine Amblyopia.
Stephany, Céleste-Élise; Ma, Xiaokuang; Dorton, Hilary M; Wu, Jie; Solomon, Alexander M; Frantz, Michael G; Qiu, Shenfeng; McGee, Aaron W
2018-05-24
Degrading vision by one eye during a developmental critical period yields enduring deficits in both eye dominance and visual acuity. A predominant model is that "reactivating" ocular dominance (OD) plasticity after the critical period is required to improve acuity in amblyopic adults. However, here we demonstrate that plasticity of eye dominance and acuity are independent and restricted by the nogo-66 receptor (ngr1) in distinct neuronal populations. Ngr1 mutant mice display greater excitatory synaptic input onto both inhibitory and excitatory neurons with restoration of normal vision. Deleting ngr1 in excitatory cortical neurons permits recovery of eye dominance but not acuity. Reciprocally, deleting ngr1 in thalamus is insufficient to rectify eye dominance but yields improvement of acuity to normal. Abolishing ngr1 expression in adult mice also promotes recovery of acuity. Together, these findings challenge the notion that mechanisms for OD plasticity contribute to the alterations in circuitry that restore acuity in amblyopia. Copyright © 2018 Elsevier Ltd. All rights reserved.
cAMP Level Modulates Scleral Collagen Remodeling, a Critical Step in the Development of Myopia
Liu, Shufeng; Fang, Fang; Lu, Runxia; Lu, Chanyi; Zheng, Min; An, Jianhong; Xu, Hongjia; Zhao, Fuxin; Chen, Jiang-fan; Qu, Jia; Zhou, Xiangtian
2013-01-01
The development of myopia is associated with decreased ocular scleral collagen synthesis in humans and animal models. Collagen synthesis is, in part, under the influence of cyclic adenosine monophosphate (cAMP). We investigated the associations between cAMP, myopia development in guinea pigs, and collagen synthesis by human scleral fibroblasts (HSFs). Form-deprived myopia (FDM) was induced by unilateral masking of guinea pig eyes. Scleral cAMP levels increased selectively in the FDM eyes and returned to normal levels after unmasking and recovery. Unilateral subconjunctival treatment with the adenylyl cyclase (AC) activator forskolin resulted in a myopic shift accompanied by reduced collagen mRNA levels, but it did not affect retinal electroretinograms. The AC inhibitor SQ22536 attenuated the progression of FDM. Moreover, forskolin inhibited collagen mRNA levels and collagen secretion by HSFs. The inhibition was reversed by SQ22536. These results demonstrate a critical role of cAMP in control of myopia development. Selective regulation of cAMP to control scleral collagen synthesis may be a novel therapeutic strategy for preventing and treating myopia. PMID:23951163
NASA Astrophysics Data System (ADS)
Rinawati, M.; Triastuti, J.; Pursetyo, K. T.
2018-04-01
The cornea is a refractive element of the eye that serves to continue the stimulation of light into the eye it has a clear, transparent, elastic and relatively thick tissue. Factors caused corneal blindness, are dystrophy, keratoconus, corneal scaring. Hydrogels can be made from polysaccharide derivatives that have gelation properties such as iota carrageenan. Therefore, it is a need to develop composite hydrogel based collagen-iota carragenan as an engineeried corneal tissue with high elasticity and hydration properties. Collagen hydrogel has a maximum water content an has equlibrium up to 40 %, less than the human cornea, 81 % and under normal hydration conditions, the human cornea can transmit 87 % of visible light. In addition, the refractive index on the surface of the cornea with air is 1.375-1.380. Based on this study, it is necessary to conduct research on the development and composition of hydrogel composite collagen-iota carrageen hydrogen based on. The best result was K5 (5:5) treatment, which has the equilibrium water content of 87.07 % and viscosity of 10.7346 Pa.s.
Gorusupudi, Aruna; Liu, Aihua; Hageman, Gregory S.; Bernstein, Paul S.
2016-01-01
The human retina is well-known to have unique lipid profiles enriched in long-chain polyunsaturated fatty acids (LC-PUFAs) and very long-chain polyunsaturated fatty acids (VLC-PUFAs) that appear to promote normal retinal structure and function, but the influence of diet on retinal lipid profiles in health and disease remains controversial. In this study, we examined two independent cohorts of donor eyes and related their retinal lipid profiles with systemic biomarkers of lipid intake. We found that serum and red blood cell lipids, and to a lesser extent orbital fat, are indeed excellent biomarkers of retinal lipid content and n-3/n-6 ratios in both the LC-PUFA and VLC-PUFA series. Eyes from age-related macular degeneration (AMD) donors have significantly decreased levels of VLC-PUFAs and low n-3/n-6 ratios. These results are consistent with the protective role of dietary n-3 LC-PUFAs against AMD and emphasize the importance of monitoring systemic biomarkers of lipid intake when undertaking clinical trials of lipid supplements for prevention and treatment of retinal disease. PMID:26764040
Influence of Misalignment on High-Order Aberration Correction for Normal Human Eyes
NASA Astrophysics Data System (ADS)
Zhao, Hao-Xin; Xu, Bing; Xue, Li-Xia; Dai, Yun; Liu, Qian; Rao, Xue-Jun
2008-04-01
Although a compensation device can correct aberrations of human eyes, the effect will be degraded by its misalignment, especially for high-order aberration correction. We calculate the positioning tolerance of correction device for high-order aberrations, and within what degree the correcting effect is better than low-order aberration (defocus and astigmatism) correction. With fixed certain misalignment within the positioning tolerance, we calculate the residual wavefront rms aberration of the first-6 to first-35 terms along with the 3rd-5th terms of aberrations corrected, and the combined first-13 terms of aberrations are also studied under the same quantity of misalignment. However, the correction effect of high-order aberrations does not meliorate along with the increase of the high-order terms under some misalignment, moreover, some simple combined terms correction can achieve similar result as complex combinations. These results suggest that it is unnecessary to correct too much the terms of high-order aberrations which are difficult to accomplish in practice, and gives confidence to correct high-order aberrations out of the laboratory.
Objective measurement of the optical image quality in the human eye
NASA Astrophysics Data System (ADS)
Navarro, Rafael M.
2001-05-01
This communication reviews some recent studies on the optical performance of the human eye. Although the retinal image cannot be recorded directly, different objective methods have been developed, which permit to determine optical quality parameters, such as the Point Spread Function (PSF), the Modulation Transfer Function (MTF), the geometrical ray aberrations or the wavefront distortions, in the living human eye. These methods have been applied in both basic and applied research. This includes the measurement of the optical performance of the eye across visual field, the optical quality of eyes with intraocular lens implants, the aberrations induced by LASIK refractive surgery, or the manufacture of customized phase plates to compensate the wavefront aberration in the eye.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Asadi, Somayeh; Masoudi, Seyed Farhad, E-mail: masoudi@kntu.ac.ir; Shahriari, Majid
In ophthalmic brachytherapy dosimetry, it is common to consider the water phantom as human eye anatomy. However, for better clinical analysis, there is a need for the dose determination in different parts of the eye. In this work, a full human eye is simulated with MCNP-4C code by considering all parts of the eye, i.e., the lens, cornea, retina, choroid, sclera, anterior chamber, optic nerve, and bulk of the eye comprising vitreous body and tumor. The average dose in different parts of this full model of the human eye is determined and the results are compared with the dose calculatedmore » in water phantom. The central axes depth dose and the dose in whole of the tumor for these 2 simulated eye models are calculated as well, and the results are compared.« less
Della Mea, Giovanni; Bacchetti, Sonia; Zeppieri, Marco; Brusini, Paolo; Cutuli, Daniela; Gigli, Gian Luigi
2007-01-01
To evaluate the ability of GDx with variable corneal compensator (VCC) compared to visual-evoked potentials (VEPs) and standard automated perimetry (SAP) in the detection of early optic nerve damage in patients with multiple sclerosis (MS). 46 eyes of 23 MS patients were included. Ten of them had a history of acute retrobulbar optic neuritis. A control group of 20 normal subjects was also included. All subjects underwent a complete ophthalmological examination and testing with SAP, GDx VCC and VEPs. 19 eyes (41.3%) were abnormal with GDx VCC compared to 38 eyes (82.6%) with SAP and 31 (64.4%) with VEPs. In the optic neuritis group, 9 eyes (69.2%) had optic nerve pallor; SAP was abnormal in 8 of these eyes (61.5%) while VEPs and GDx VCC were abnormal in 6 eyes (46.1%). 2/20 eyes (10.0%) in the control group gave a false-positive abnormal result with SAP. GDx VCC and VEP were normal for all the eyes in the control group. GDx VCC is less able to detect early defects in MS patients compared to the currently used standard techniques of SAP and VEPs. Copyright (c) 2007 S. Karger AG, Basel.
Chang, Bo
2016-01-01
Leber's congenital amaurosis (LCA) is an inherited retinal degenerative disease characterized by severe loss of vision in the first year of life. In addition to early vision loss, a variety of other eye-related abnormalities including roving eye movements, deep-set eyes, and sensitivity to bright light also occur with this disease. Many animal models of LCA are available and the study them has led to a better understanding of the pathology of the disease, and has led to the development of therapeutic strategies aimed at curing or slowing down LCA. Mouse models, with their well-developed genetics and similarity to human physiology and anatomy, serve as powerful tools with which to investigate the etiology of human LCA. Such mice provide reproducible, experimental systems for elucidating pathways of normal development, function, designing strategies and testing compounds for translational research and gene-based therapies aimed at delaying the diseases progression. In this chapter, I describe tools used in the discovery and evaluation of mouse models of LCA including a Phoenix Image-Guided Optical Coherence Tomography (OCT) and a Diagnosys Espion Visual Electrophysiology System. Three mouse models are described, the rd3 mouse model for LCA12 and LCA1, the rd12 mouse model for LCA2, and the rd16 mouse model for LCA10.
Photoreceptor disc shedding in the living human eye
Kocaoglu, Omer P.; Liu, Zhuolin; Zhang, Furu; Kurokawa, Kazuhiro; Jonnal, Ravi S.; Miller, Donald T.
2016-01-01
Cone photoreceptors undergo a daily cycle of renewal and shedding of membranous discs in their outer segments (OS), the portion responsible for light capture. These physiological processes are fundamental to maintaining photoreceptor health, and their dysfunction is associated with numerous retinal diseases. While both processes have been extensively studied in animal models and postmortem eyes, little is known about them in the living eye, in particular human. In this study, we report discovery of the optical signature associated with disc shedding using a method based on adaptive optics optical coherence tomography (AO-OCT) in conjunction with post-processing methods to track and monitor individual cone cells in 4D. The optical signature of disc shedding is characterized by an abrupt transient loss in the cone outer segment tip (COST) reflection followed by its return that is axially displaced anteriorly. Using this signature, we measured the temporal and spatial properties of shedding events in three normal subjects. Average duration of the shedding event was 8.8 ± 13.4 minutes, and average length loss of the OS was 2.1 μm (7.0% of OS length). Prevalence of cone shedding was highest in the morning (14.3%) followed by the afternoon (5.7%) and evening (4.0%), with load distributed across the imaged patch. To the best of our knowledge these are the first images of photoreceptor disc shedding in the living retina. PMID:27895995
Ertan, Aylin; Karacal, Humeyra
2008-10-01
To compare accuracy of LASIK flap and INTACS centration following femtosecond laser application in normal and keratoconic eyes. This is a retrospective case series comprising 133 eyes of 128 patients referred for refractive surgery. All eyes were divided into two groups according to preoperative diagnosis: group 1 (LASIK group) comprised 74 normal eyes of 72 patients undergoing LASIK with a femtosecond laser (IntraLase), and group 2 (INTACS group) consisted of 59 eyes of 39 patients with keratoconus for whom INTACS were implanted using a femtosecond laser (IntraLase). Decentration of the LASIK flap and INTACS was analyzed using Pentacam. Temporal decentration was 612.56 +/- 384.24 microm (range: 30 to 2120 microm) in the LASIK group and 788.33 +/- 500.34 microm (range: 30 to 2450 microm) in the INTACS group. A statistically significant difference was noted between the groups in terms of decentration (P < .05). Regression analysis showed that the amount of decentration of the LASIK flap and INTACS correlated with the central corneal thickness in the LASIK group and preoperative sphere and cylinder in the INTACS group, respectively. Decentration with the IntraLase occurred in most cases, especially in keratoconic eyes. The applanation performed for centralization during IntraLase application may flatten and shift the pupil center, and thus cause decentralization of the LASIK flap and INTACS. Central corneal thickness in the LASIK group and preoperative sphere and cylinder in the INTACS group proved to be statistically significant parameters associated with decentration.
Stimulation of pontine reticular formation in monkeys with strabismus.
Walton, Mark M G; Ono, Seiji; Mustari, Michael J
2013-10-29
Saccade disconjugacy in strabismus could result from any of a number of factors, including abnormalities of eye muscles, the plant, motoneurons, near response cells, or atypical tuning of neurons in saccade-related areas of the brain. This study was designed to investigate the possibility that saccade disconjugacy in strabismus is associated with abnormalities in paramedian pontine reticular formation (PPRF). We applied microstimulation to 22 sites in PPRF and 20 sites in abducens nucleus in three rhesus macaque monkeys (one normal, one esotrope, and one exotrope). When mean velocity was compared between the two eyes, a slight difference was found for 1/5 sites in the normal animal. Significant differences were found for 5/6 sites in an esotrope and 10/11 sites in an exotrope. For five sites in the strabismic monkeys, the directions of evoked movements differed by more than 40° between the two eyes. When stimulation was applied to abducens nucleus (20 sites), the ipsilateral eye moved faster for 4/6 sites in the normal animal and all nine sites in the esotrope. For the exotrope, however, the left eye always moved faster, even for three sites on the right side. For the strabismic animals, stimulation of abducens nucleus often caused a different eye to move faster than stimulation of PPRF. These data suggest that PPRF is organized at least partly monocularly in strabismus and that disconjugate saccades are at least partly a consequence of unbalanced saccadic commands being sent to the two eyes.
Ghassemi, Fariba; Mirshahi, Reza; Bazvand, Fatemeh; Fadakar, Kaveh; Faghihi, Houshang; Sabour, Siamak
2017-12-01
To provide normative data of foveal avascular zone (FAZ) and thickness. In this cross-sectional study both eyes of each normal subject were scanned with optical coherence tomography angiography (OCTA) for foveal superficial and deep avascular zone (FAZ) and central foveal thickness (CFT) and parafoveal thickness (PFT). Out of a total of 224 eyes of 112 volunteers with a mean age of 37.03 (12-67) years, the mean superficial FAZ area was 0.27 mm 2 , and deep FAZ area was 0.35 mm 2 ( P < 0.001), with no difference between both eyes. Females had a larger superficial (0.32 ± 0.11 mm 2 versus 0.23 ± 0.09 mm 2 ) and deep FAZ (0.40 ± 0.14 mm 2 versus 0.31 ± 0.10 mm 2 ) ( P < 0.001) than males. By multivariate linear regression analysis, in normal eyes, superficial FAZ area varied significantly with the gender, CFT, and deep FAZ. Deep FAZ varied with the gender and CFT. The gender and CFT influence the size of normal superficial and deep FAZ of capillary network.
Chong, Raymond K Y; Mills, Bradley; Dailey, Leanna; Lane, Elizabeth; Smith, Sarah; Lee, Kyoung-Hyun
2010-07-01
We tested the hypothesis that a computational overload results when two activities, one motor and the other cognitive that draw on the same neural processing pathways, are performed concurrently. Healthy young adult subjects carried out two seemingly distinct tasks of maintaining standing balance control under conditions of low (eyes closed), normal (eyes open) or high (eyes open, sway-referenced surround) visuospatial processing load while concurrently performing a cognitive task of either subtracting backwards by seven or generating words of the same first letter. A decrease in the performance of the balance control task and a decrement in the speed and accuracy of responses were noted during the subtraction but not the word generation task. The interference in the subtraction task was isolated to the first trial of the high but not normal or low visuospatial conditions. Balance control improvements with repeated exposures were observed only in the low visuospatial conditions while performance in the other conditions remained compromised. These results suggest that sensory organization for balance control appear to draw on similar visuospatial computational resources needed for the subtraction but not the word generation task. In accordance with the theory of modularity in human performance, the contrast in results between the subtraction and word generation tasks suggests that the neural overload is related to competition for similar visuospatial processes rather than limited attentional resources. Copyright (c) 2010 Elsevier Ltd. All rights reserved.
Applegate, Raymond A.; Donnelly, William J.; Marsack, Jason D.; Koenig, Darren E.; Pesudovs, Konrad
2007-01-01
We report root-mean-square (RMS) wavefront error (WFE) for individual aberrations and cumulative high-order (HO) RMS WFE for the normal human eye as a function of age by decade and pupil diameter in 1 mm steps from 3 to 7 mm and determine the relationship among HO RMS WFE, mean age for each decade of life, and luminance for physiologic pupil diameters. Subjects included 146 healthy individuals from 20 to 80 years of age. Ocular aberration was measured on the preferred eye of each subject (for a total of 146 eyes through dilated pupils; computed for 3, 4, 5, 6, and 7 mm pupils; and described with a tenth-radial-order normalized Zernike expansion. We found that HO RMS WFE increases faster with increasing pupil diameter for any given age and pupil diameter than it does with increasing age alone. A planar function accounts for 99% of the variance in the 3-D space defined by mean log HO RMS WFE, mean age for each decade of life, and pupil diameter. When physiologic pupil diameters are used to estimate HO RMS WFE as a function of luminance and age, at low luminance (9 cd/m2) HO RMS WFE decreases with increasing age. This normative data set details (1) the 3-D relationship between HO RMS WFE and age for fixed pupil diameters and (2) the 3-D relationship among HO RMS WFE, age, and luminance for physiologic pupil diameters. PMID:17301847
Kaluzhny, Yulia; Kandárová, Helena; d'Argembeau-Thornton, Laurence; Kearney, Paul; Klausner, Mitchell
2015-08-23
To comply with the Seventh Amendment to the EU Cosmetics Directive and EU REACH legislation, validated non-animal alternative methods for reliable and accurate assessment of ocular toxicity in man are needed. To address this need, we have developed an eye irritation test (EIT) which utilizes a three dimensional reconstructed human cornea-like epithelial (RhCE) tissue model that is based on normal human cells. The EIT is able to separate ocular irritants and corrosives (GHS Categories 1 and 2 combined) and those that do not require labeling (GHS No Category). The test utilizes two separate protocols, one designed for liquid chemicals and a second, similar protocol for solid test articles. The EIT prediction model uses a single exposure period (30 min for liquids, 6 hr for solids) and a single tissue viability cut-off (60.0% as determined by the MTT assay). Based on the results for 83 chemicals (44 liquids and 39 solids) EIT achieved 95.5/68.2/ and 81.8% sensitivity/specificity and accuracy (SS&A) for liquids, 100.0/68.4/ and 84.6% SS&A for solids, and 97.6/68.3/ and 83.1% for overall SS&A. The EIT will contribute significantly to classifying the ocular irritation potential of a wide range of liquid and solid chemicals without the use of animals to meet regulatory testing requirements. The EpiOcular EIT method was implemented in 2015 into the OECD Test Guidelines as TG 492.
Kaluzhny, Yulia; Kandárová, Helena; d’Argembeau-Thornton, Laurence; Kearney, Paul; Klausner, Mitchell
2015-01-01
To comply with the Seventh Amendment to the EU Cosmetics Directive and EU REACH legislation, validated non-animal alternative methods for reliable and accurate assessment of ocular toxicity in man are needed. To address this need, we have developed an eye irritation test (EIT) which utilizes a three dimensional reconstructed human cornea-like epithelial (RhCE) tissue model that is based on normal human cells. The EIT is able to separate ocular irritants and corrosives (GHS Categories 1 and 2 combined) and those that do not require labeling (GHS No Category). The test utilizes two separate protocols, one designed for liquid chemicals and a second, similar protocol for solid test articles. The EIT prediction model uses a single exposure period (30 min for liquids, 6 hr for solids) and a single tissue viability cut-off (60.0% as determined by the MTT assay). Based on the results for 83 chemicals (44 liquids and 39 solids) EIT achieved 95.5/68.2/ and 81.8% sensitivity/specificity and accuracy (SS&A) for liquids, 100.0/68.4/ and 84.6% SS&A for solids, and 97.6/68.3/ and 83.1% for overall SS&A. The EIT will contribute significantly to classifying the ocular irritation potential of a wide range of liquid and solid chemicals without the use of animals to meet regulatory testing requirements. The EpiOcular EIT method was implemented in 2015 into the OECD Test Guidelines as TG 492. PMID:26325674
Feng, Lili; Ju, Meihua; Lee, Kei Ying V; Mackey, Ashley; Evangelista, Mariasilvia; Iwata, Daiju; Adamson, Peter; Lashkari, Kameran; Foxton, Richard; Shima, David; Ng, Yin Shan
2017-10-01
Current treatments for choroidal neovascularization, a major cause of blindness for patients with age-related macular degeneration, treat symptoms but not the underlying causes of the disease. Inflammation has been strongly implicated in the pathogenesis of choroidal neovascularization. We examined the inflammatory role of Toll-like receptor 2 (TLR2) in age-related macular degeneration. TLR2 was robustly expressed by the retinal pigment epithelium in mouse and human eyes, both normal and with macular degeneration/choroidal neovascularization. Nuclear localization of NF-κB, a major downstream target of TLR2 signaling, was detected in the retinal pigment epithelium of human eyes, particularly in eyes with advanced stages of age-related macular degeneration. TLR2 antagonism effectively suppressed initiation and growth of spontaneous choroidal neovascularization in a mouse model, and the combination of anti-TLR2 and antivascular endothelial growth factor receptor 2 yielded an additive therapeutic effect on both area and number of spontaneous choroidal neovascularization lesions. Finally, in primary human fetal retinal pigment epithelium cells, ligand binding to TLR2 induced robust expression of proinflammatory cytokines, and end products of lipid oxidation had a synergistic effect on TLR2 activation. Our data illustrate a functional role for TLR2 in the pathogenesis of choroidal neovascularization, likely by promoting inflammation of the retinal pigment epithelium, and validate TLR2 as a novel therapeutic target for reducing choroidal neovascularization. Copyright © 2017 American Society for Investigative Pathology. Published by Elsevier Inc. All rights reserved.
Eye examination in the cat: Step-by-step approach and common findings.
Stiles, Jean; Kimmitt, Beth
2016-09-01
The ability to perform a complete eye examination in the cat is critically important for patients with an ocular disorder or a systemic disease, as well as for the geriatric cat. Cats may need short breaks between portions of the eye exam in order to minimize stress. For the clinician, use of ophthalmic equipment and interpretation of normal vs abnormal findings may take some practice in order to develop proficiency. This review is aimed at veterinary practitioners and outlines all the steps and equipment necessary to perform a complete ophthalmic examination in the cat. Although some specialized equipment is required, a complete eye exam can be performed with a modest investment in equipment and supplies. This article draws on published references for normal parameters measured in the feline eye exam, as well as the experience of the authors. © The Author(s) 2016.
Scanning mid-IR laser apparatus with eye tracking for refractive surgery
NASA Astrophysics Data System (ADS)
Telfair, William B.; Yoder, Paul R., Jr.; Bekker, Carsten; Hoffman, Hanna J.; Jensen, Eric F.
1999-06-01
A robust, real-time, dynamic eye tracker has been integrated with the short pulse mid-infrared laser scanning delivery system previously described. This system employs a Q- switched Nd:YAG laser pumped optical parametric oscillator operating at 2.94 micrometers. Previous ablation studies on human cadaver eyes and in-vivo cat eyes demonstrated very smooth ablations with extremely low damage levels similar to results with an excimer. A 4-month healing study with cats indicated no adverse healing effects. In order to treat human eyes, the tracker is required because the eyes move during the procedure due to both voluntary and involuntary motions such as breathing, heartbeat, drift, loss of fixation, saccades and microsaccades. Eye tracking techniques from the literature were compared. A limbus tracking system was best for this application. Temporal and spectral filtering techniques were implemented to reduce tracking errors, reject stray light, and increase signal to noise ratio. The expanded-capability system (IRVision AccuScan 2000 Laser System) has been tested in the lab on simulated eye targets, glass eyes, cadaver eyes, and live human subjects. Circular targets ranging from 10-mm to 14-mm diameter were successfully tracked. The tracker performed beyond expectations while the system performed myopic photorefractive keratectomy procedures on several legally blind human subjects.
The perceptual consequences of interocular suppression in amblyopia.
Maehara, Goro; Thompson, Benjamin; Mansouri, Behzad; Farivar, Reza; Hess, Robert F
2011-11-21
It is known that information from an amblyopic eye can be strongly suppressed when both eyes are open. The authors investigated the way in which suppression influences the relative perception of suprathreshold contrast and luminance between a person's eyes under dichoptic viewing conditions. Stimuli consisted of four patches of luminance or four patches containing gratings. Two patches were presented to each eye. Ten amblyopes with mild suppression (six strabismic, three anisometropic and strabismic, and one deprivation; mean age, 34.5 years) and three control observers with normal vision (mean age, 33.0 years) matched the appearance of the stimuli presented to each eye. The match involved manipulation of either luminance or contrast. Amblyopes with mild suppression decreased stimulus luminance in the fellow fixing eye or increased luminance in the amblyopic eye to achieve a match (mean matching luminance, 21.1 and 39.6 cd/m(2) for the fellow fixing eye and the amblyopic eye, respectively; standard luminance, 30 cd/m(2)). This interocular mismatch was also observed when luminance was variable and contrast was kept constant (mean matching luminance, 22.8 cd/m(2) for the fellow fixing eye). On the other hand, the amblyopic eye showed no loss of perceived contrast. There was little or no mismatch between the two eyes of control participants with normal binocular vision. Amblyopes have monocular deficits in contrast perception but dichoptic deficits in luminance perception, suggesting that suppression in its mild form involves luminance processing.
Nita, Małgorzata; Grzybowski, Andrzej
2016-01-01
The reactive oxygen species (ROS) form under normal physiological conditions and may have both beneficial and harmful role. We search the literature and current knowledge in the aspect of ROS participation in the pathogenesis of anterior and posterior eye segment diseases in adults. ROS take part in the pathogenesis of keratoconus, Fuchs endothelial corneal dystrophy, and granular corneal dystrophy type 2, stimulating apoptosis of corneal cells. ROS play a role in the pathogenesis of glaucoma stimulating apoptotic and inflammatory pathways on the level of the trabecular meshwork and promoting retinal ganglion cells apoptosis and glial dysfunction in the posterior eye segment. ROS play a role in the pathogenesis of Leber's hereditary optic neuropathy and traumatic optic neuropathy. ROS induce apoptosis of human lens epithelial cells. ROS promote apoptosis of vascular and neuronal cells and stimulate inflammation and pathological angiogenesis in the course of diabetic retinopathy. ROS are associated with the pathophysiological parainflammation and autophagy process in the course of the age-related macular degeneration. PMID:26881021
Chiang, Peggy P C; Zheng, Yingfeng; Wong, Tien Y; Lamoureux, Ecosse L
2013-02-01
To quantify the eye disease-specific impact of unilateral and bilateral vision impairment (VI) on vision-specific functioning (VF). The Singapore Indian Eye population-based study. Ethnic Indians older than 40 years of age living in Singapore. Participants underwent standardized ophthalmic assessments for VI and blindness, defined using presenting visual acuity (United States definition). Sociodemographic data were recorded using a standardized questionnaire. Rasch analysis was used to validate the Visual Function Index 11 and to determine its psychometric properties. The major causes of VI (i.e., cataract, refractive error, age-related macular degeneration, diabetic retinopathy [DR], and glaucoma) were determined by ophthalmologists on examination. Multivariate linear regression analysis was performed to assess the impact of VI on the overall VF Rasch score. Vision-specific functioning. Three thousand three hundred ninety-six persons were analyzed. Participants with VI had a systematic reduction in VF score compared with those with normal vision in both eyes, ranging from -11.2% normal vision in one eye and low vision in the other eye (95% confidence interval [CI], -12.2% to -10.3%; P<0.001), to -12.7% blindness in one eye and normal vision in the other eye (CI, -15.1% to -10.4%; P<0.001), to -19.4% low vision in both eyes (CI, -20.8% to -18.1%; P<0.001), to -52.9% blindness in one eye and low vision in other eye (CI, -55.3% to -50.4%; P<0.001), to -77.2% blindness in both eyes (CI, -82.4% to 72.0%; P<0.001). The impact of VI on VF score varied across different major causes of vision loss, regardless of socioeconomic factors. Vision impairment attributed to cataract in one or both eyes had a significant decrease in VF score by 17.7% and 22.3%, respectively, compared with those with normal vision in both eyes (P<0.001). The impact of unilateral and bilateral VI on VF score was greater in participants with glaucoma (32.2% in unilateral cases and 35.9% in bilateral cases; P<0.001) and DR (29.4% in unilateral cases and 33.3% in bilateral cases; P<0.001). Vision impairment and major age-related eye diseases such as cataract, DR, and glaucoma are associated significantly with worse deterioration in VF, regardless of education level, literacy adequacy, or immigration pattern. Glaucoma and DR seemed to have a greater negative impact on VF score compared with cataract. This study highlights the importance of disease-specific interventions in reducing the adverse impact of VI on daily activities. Copyright © 2013 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
Apnea-induced rapid eye movement sleep disruption impairs human spatial navigational memory.
Varga, Andrew W; Kishi, Akifumi; Mantua, Janna; Lim, Jason; Koushyk, Viachaslau; Leibert, David P; Osorio, Ricardo S; Rapoport, David M; Ayappa, Indu
2014-10-29
Hippocampal electrophysiology and behavioral evidence support a role for sleep in spatial navigational memory, but the role of particular sleep stages is less clear. Although rodent models suggest the importance of rapid eye movement (REM) sleep in spatial navigational memory, a similar role for REM sleep has never been examined in humans. We recruited subjects with severe obstructive sleep apnea (OSA) who were well treated and adherent with continuous positive airway pressure (CPAP). Restricting CPAP withdrawal to REM through real-time monitoring of the polysomnogram provides a novel way of addressing the role of REM sleep in spatial navigational memory with a physiologically relevant stimulus. Individuals spent two different nights in the laboratory, during which subjects performed timed trials before and after sleep on one of two unique 3D spatial mazes. One night of sleep was normally consolidated with use of therapeutic CPAP throughout, whereas on the other night, CPAP was reduced only in REM sleep, allowing REM OSA to recur. REM disruption via this method caused REM sleep reduction and significantly fragmented any remaining REM sleep without affecting total sleep time, sleep efficiency, or slow-wave sleep. We observed improvements in maze performance after a night of normal sleep that were significantly attenuated after a night of REM disruption without changes in psychomotor vigilance. Furthermore, the improvement in maze completion time significantly positively correlated with the mean REM run duration across both sleep conditions. In conclusion, we demonstrate a novel role for REM sleep in human memory formation and highlight a significant cognitive consequence of OSA. Copyright © 2014 the authors 0270-6474/14/3414571-07$15.00/0.
NEIBank: Genomics and bioinformatics resources for vision research
Peterson, Katherine; Gao, James; Buchoff, Patee; Jaworski, Cynthia; Bowes-Rickman, Catherine; Ebright, Jessica N.; Hauser, Michael A.; Hoover, David
2008-01-01
NEIBank is an integrated resource for genomics and bioinformatics in vision research. It includes expressed sequence tag (EST) data and sequence-verified cDNA clones for multiple eye tissues of several species, web-based access to human eye-specific SAGE data through EyeSAGE, and comprehensive, annotated databases of known human eye disease genes and candidate disease gene loci. All expression- and disease-related data are integrated in EyeBrowse, an eye-centric genome browser. NEIBank provides a comprehensive overview of current knowledge of the transcriptional repertoires of eye tissues and their relation to pathology. PMID:18648525
Effects of monocular viewing and eye dominance on spatial attention.
Roth, Heidi L; Lora, Andrea N; Heilman, Kenneth M
2002-09-01
Observations in primates and patients with unilateral spatial neglect have suggested that patching of the eye ipsilateral to the injury and contralateral to the neglected space can sometimes improve attention to the neglected space. Investigators have generally attributed the effects of monocular eye patching to activation of subcortical centers that interact with cortical attentional systems. Eye patching is thought to produce preferential activation of attentional systems contralateral to the viewing eye. In this study we examined the effect of monocular eye patching on attentional biases in normal subjects. When normal subjects bisect vertical (radial) lines using both eyes, they demonstrate a far attentional bias, misbisecting lines away from their body. In a monocular viewing experiment, we found that the majority of subjects, who were right eye dominant, had relatively nearer bisections and a diminished far bias when they used their right eye (left eye covered) compared with when they used their left eye (right eye covered). The smaller group of subjects who were left eye dominant had relatively nearer bisections and a diminished far bias when they used their left eye compared with when they used their right eye. In the hemispatial placement experiment, we directly manipulated hemispheric engagement by having subjects perform the same task in right and left hemispace. We found that right eye dominant subjects had a diminished far bias in right hemispace relative to left hemispace. Left eye dominant subjects showed the opposite pattern and had a diminished far bias in left hemispace. For both groups, spatial presentation affected performance more for the non-dominant eye. The results suggest that monocular viewing is associated with preferential activation of attentional systems in the contralateral hemisphere, and that the right hemisphere (at least in right eye dominant subjects) is biased towards far space. Finally, the results suggest that the poorly understood phenomenon of eye dominance may be related to hemispheric specialization for visual attention.
Effects of configural processing on the perceptual spatial resolution for face features.
Namdar, Gal; Avidan, Galia; Ganel, Tzvi
2015-11-01
Configural processing governs human perception across various domains, including face perception. An established marker of configural face perception is the face inversion effect, in which performance is typically better for upright compared to inverted faces. In two experiments, we tested whether configural processing could influence basic visual abilities such as perceptual spatial resolution (i.e., the ability to detect spatial visual changes). Face-related perceptual spatial resolution was assessed by measuring the just noticeable difference (JND) to subtle positional changes between specific features in upright and inverted faces. The results revealed robust inversion effect for spatial sensitivity to configural-based changes, such as the distance between the mouth and the nose, or the distance between the eyes and the nose. Critically, spatial resolution for face features within the region of the eyes (e.g., the interocular distance between the eyes) was not affected by inversion, suggesting that the eye region operates as a separate 'gestalt' unit which is relatively immune to manipulations that would normally hamper configural processing. Together these findings suggest that face orientation modulates fundamental psychophysical abilities including spatial resolution. Furthermore, they indicate that classic psychophysical methods can be used as a valid measure of configural face processing. Copyright © 2015 Elsevier Ltd. All rights reserved.
Discrimination between smiling faces: Human observers vs. automated face analysis.
Del Líbano, Mario; Calvo, Manuel G; Fernández-Martín, Andrés; Recio, Guillermo
2018-05-11
This study investigated (a) how prototypical happy faces (with happy eyes and a smile) can be discriminated from blended expressions with a smile but non-happy eyes, depending on type and intensity of the eye expression; and (b) how smile discrimination differs for human perceivers versus automated face analysis, depending on affective valence and morphological facial features. Human observers categorized faces as happy or non-happy, or rated their valence. Automated analysis (FACET software) computed seven expressions (including joy/happiness) and 20 facial action units (AUs). Physical properties (low-level image statistics and visual saliency) of the face stimuli were controlled. Results revealed, first, that some blended expressions (especially, with angry eyes) had lower discrimination thresholds (i.e., they were identified as "non-happy" at lower non-happy eye intensities) than others (especially, with neutral eyes). Second, discrimination sensitivity was better for human perceivers than for automated FACET analysis. As an additional finding, affective valence predicted human discrimination performance, whereas morphological AUs predicted FACET discrimination. FACET can be a valid tool for categorizing prototypical expressions, but is currently more limited than human observers for discrimination of blended expressions. Configural processing facilitates detection of in/congruence(s) across regions, and thus detection of non-genuine smiling faces (due to non-happy eyes). Copyright © 2018 Elsevier B.V. All rights reserved.
ERIC Educational Resources Information Center
Colicchia, G.; Wiesner, H.; Waltner, C.; Zollman, D.
2008-01-01
We describe a model of the human eye that incorporates a variable converging lens. The model can be easily constructed by students with low-cost materials. It shows in a comprehensible way the functionality of the eye's optical system. Images of near and far objects can be focused. Also, the defects of near and farsighted eyes can be demonstrated.
Straightening the Eyes Doesn't Rebalance the Brain
Zhou, Jiawei; Wang, Yonghua; Feng, Lixia; Wang, Jiafeng; Hess, Robert F.
2017-01-01
Surgery to align the two eyes is commonly used in treating strabismus. However, the role of strabismic surgery on patients' binocular visual processing is not yet fully understood. In this study, we asked two questions: (1) Does realigning the eyes by strabismic surgery produce an immediate benefit to patients' sensory eye balance? (2) If not, is there a subsequent period of “alignment adaptation” akin to refractive adaptation where sensory benefits to binocular function accrue? Seventeen patients with strabismus (mean age: 17.06 ± 5.16 years old) participated in our experiment. All participants had normal or corrected to normal visual acuity (LogMAR < 0.10) in the two eyes. We quantitatively measured their sensory eye balance before and after surgery using a binocular phase combination paradigm. For the seven patients whose sensory eye balance was measured before surgery, we found no significant change [t(6) = −0.92; p = 0.39] in the sensory eye balance measured 0.5–1 months after the surgery, indicating that the surgical re-alignment didn't by itself produce any immediate benefit for sensory eye balance. To answer the second question, we measured 16 patients' sensory eye balance at around 5–12 months after their eyes had been surgically re-aligned and compared this with our measurements 0.5–1 months after surgery. We found no significant change [t(15) = −0.89; p = 0.39] in sensory eye balance 5–12 months after the surgery. These results suggest that strabismic surgery while being necessary is not itself sufficient for re-establishing balanced sensory eye dominance. PMID:28955214
Central Connections of the Lacrimal Functional Unit.
Willshire, Catherine; Buckley, Roger J; Bron, Anthony J
2017-08-01
To study the contribution of each eye to the reflex tear response, after unilateral and bilateral topical anesthesia. A closed-eye, modified Schirmer test was performed bilaterally in 8 normal subjects, in a controlled environment chamber set to 23°C, 45% relative humidity, and 0.08 m/s airflow. Eye drops were instilled into each eye 10 minutes before the Schirmer test. Experiments were as follows: 1) bilateral saline (control), 2) unilateral anesthesia (ipsilateral anesthetic; contralateral saline), and 3) bilateral anesthesia. There was no difference in between-eye wetting lengths in the saline control eyes (P = 0.394) or the bilaterally anesthetized eyes (P = 0.171). The wetting length was reduced in both eyes after bilateral anesthesia compared with saline controls (P = 0.001; P ≤ 0.0005). After unilateral anesthesia, the wetting length was reduced in the anesthetized eye compared with its saline control by 51.4% (P ≤ 0.0005) and compared with its fellow, unanesthetized eye (P = 0.005). The fellow eye value was also reduced compared with its saline control (P = 0.06). The wetting length was reduced by topical anesthesia, when instilled bilaterally and ipsilaterally. The latter response implies an ipsilateral, reflex sensory drive to lacrimal secretion. In the unanesthetized fellow eye, the reduction compared with its saline control was not quite significant. This implies a relative lack of central, sensory, reflex cross-innervation, although the possibility cannot entirely be ruled out. These results are relevant to the possibility of reflex lacrimal compensation from a normal fellow eye, in cases of unilateral corneal anesthesia.
Goodarzi, Naser; Dabbaghi, Parviz; Valipour, Habib; Vafadari, Behnam
2015-01-01
Introduction: Based on the previous studies, we know that the hemispheric lateralization defects, increase the probability of psychological disorders. We also know that dominant limb is controlled by dominant hemisphere and limb preference is used as an indicator for hemisphere dominance. In this study we attempted to explore the hemispheric dominance by the use of three limbs (hand, foot and eye). Methods: We performed this survey on two samples, psychiatric patients compared with normal population. For this purpose, knowing that the organ dominance is stabilized in adolescence, and age has no effect on the people above 15, we used 48 high school girls and 65 boys as the final samples of normal population. The patient group included 57 male and 26 female who were chronic psychiatric patients. Results: The result shows that left-eye dominance is more in patients than the normal group (P=0.000) but the handedness and footedness differences are not significance. In psychotic, bipolar and depressive disorders, eye dominance had significant difference (P=0.018). But this is not true about hand and foot dominance. Discussion: Our findings proved that generally in psychiatric patients, left-eye dominance is more common, left-eye dominance is also more in psychotic and depressive disorders. It is less common in bipolar disorders. PMID:27307954
Corneal endothelial cell density and morphology in normal Iranian eyes
Hashemian, Mohammad Nasser; Moghimi, Sasan; Fard, Masood Aghsaie; Fallah, Mohammad Reza; Mansouri, Mohammad Reza
2006-01-01
Background We describe corneal endothelial cell density and morphology in normal Iranian eyes and compare endothelial cell characteristics in the Iranian population with data available in the literature for American and Indian populations. Methods Specular microscopy was performed in 525 eyes of normal Iranian people aged 20 to 85 years old. The studied parameters including mean endothelial cell density (MCD), mean cell area (MCA) and coefficient of variation (CV) in cell area were analyzed in all of the 525 eyes. Results MCD was 1961 ± 457 cell/mm2 and MCA was 537.0 ± 137.4 μm2. There was no statistically significant difference in MCD, MCA and CV between genders (Student t-test, P = 0.85, P = 0.97 and P = 0.15 respectively). There was a statistically significant decrease in MCD with age (P < 0.001, r = -0.64). The rate of cell loss was 0.6% per year. There was also a statistically significant increase in MCA (P < 0.001,r = 0.56) and CV (P < 0.001, r = 0.30) from 20 to 85 years of age. Conclusion The first normative data for the endothelium of Iranian eyes seems to confirm that there are no differences in MCD, MCA and CV between genders. Nevertheless, the values obtained in Iranian eyes seem to be different to those reported by the literature in Indian and American populations. PMID:16519812
Corneal endothelial cell density and morphology in normal Iranian eyes.
Hashemian, Mohammad Nasser; Moghimi, Sasan; Fard, Masood Aghsaie; Fallah, Mohammad Reza; Mansouri, Mohammad Reza
2006-03-06
We describe corneal endothelial cell density and morphology in normal Iranian eyes and compare endothelial cell characteristics in the Iranian population with data available in the literature for American and Indian populations. Specular microscopy was performed in 525 eyes of normal Iranian people aged 20 to 85 years old. The studied parameters including mean endothelial cell density (MCD), mean cell area (MCA) and coefficient of variation (CV) in cell area were analyzed in all of the 525 eyes. MCD was 1961 +/- 457 cell/mm2 and MCA was 537.0 +/- 137.4 microm2. There was no statistically significant difference in MCD, MCA and CV between genders (Student t-test, P = 0.85, P = 0.97 and P = 0.15 respectively). There was a statistically significant decrease in MCD with age (P < 0.001, r = -0.64). The rate of cell loss was 0.6% per year. There was also a statistically significant increase in MCA (P < 0.001,r = 0.56) and CV (P < 0.001, r = 0.30) from 20 to 85 years of age. The first normative data for the endothelium of Iranian eyes seems to confirm that there are no differences in MCD, MCA and CV between genders. Nevertheless, the values obtained in Iranian eyes seem to be different to those reported by the literature in Indian and American populations.
Binocular eye movement control and motion perception: what is being tracked?
van der Steen, Johannes; Dits, Joyce
2012-10-19
We investigated under what conditions humans can make independent slow phase eye movements. The ability to make independent movements of the two eyes generally is attributed to few specialized lateral eyed animal species, for example chameleons. In our study, we showed that humans also can move the eyes in different directions. To maintain binocular retinal correspondence independent slow phase movements of each eye are produced. We used the scleral search coil method to measure binocular eye movements in response to dichoptically viewed visual stimuli oscillating in orthogonal direction. Correlated stimuli led to orthogonal slow eye movements, while the binocularly perceived motion was the vector sum of the motion presented to each eye. The importance of binocular fusion on independency of the movements of the two eyes was investigated with anti-correlated stimuli. The perceived global motion pattern of anti-correlated dichoptic stimuli was perceived as an oblique oscillatory motion, as well as resulted in a conjugate oblique motion of the eyes. We propose that the ability to make independent slow phase eye movements in humans is used to maintain binocular retinal correspondence. Eye-of-origin and binocular information are used during the processing of binocular visual information, and it is decided at an early stage whether binocular or monocular motion information and independent slow phase eye movements of each eye are produced during binocular tracking.
Binocular Eye Movement Control and Motion Perception: What Is Being Tracked?
van der Steen, Johannes; Dits, Joyce
2012-01-01
Purpose. We investigated under what conditions humans can make independent slow phase eye movements. The ability to make independent movements of the two eyes generally is attributed to few specialized lateral eyed animal species, for example chameleons. In our study, we showed that humans also can move the eyes in different directions. To maintain binocular retinal correspondence independent slow phase movements of each eye are produced. Methods. We used the scleral search coil method to measure binocular eye movements in response to dichoptically viewed visual stimuli oscillating in orthogonal direction. Results. Correlated stimuli led to orthogonal slow eye movements, while the binocularly perceived motion was the vector sum of the motion presented to each eye. The importance of binocular fusion on independency of the movements of the two eyes was investigated with anti-correlated stimuli. The perceived global motion pattern of anti-correlated dichoptic stimuli was perceived as an oblique oscillatory motion, as well as resulted in a conjugate oblique motion of the eyes. Conclusions. We propose that the ability to make independent slow phase eye movements in humans is used to maintain binocular retinal correspondence. Eye-of-origin and binocular information are used during the processing of binocular visual information, and it is decided at an early stage whether binocular or monocular motion information and independent slow phase eye movements of each eye are produced during binocular tracking. PMID:22997286
MedlinePlus Videos and Cool Tools
... to prevent harmful substances from getting in the eyes. During the normal course of a day, a ... of 15 times a minute to keep the eyes healthy. The lacrimal gland provides lubricating fluid for ...
Sesin, Anaelis; Adjouadi, Malek; Cabrerizo, Mercedes; Ayala, Melvin; Barreto, Armando
2008-01-01
This study developed an adaptive real-time human-computer interface (HCI) that serves as an assistive technology tool for people with severe motor disability. The proposed HCI design uses eye gaze as the primary computer input device. Controlling the mouse cursor with raw eye coordinates results in sporadic motion of the pointer because of the saccadic nature of the eye. Even though eye movements are subtle and completely imperceptible under normal circumstances, they considerably affect the accuracy of an eye-gaze-based HCI. The proposed HCI system is novel because it adapts to each specific user's different and potentially changing jitter characteristics through the configuration and training of an artificial neural network (ANN) that is structured to minimize the mouse jitter. This task is based on feeding the ANN a user's initially recorded eye-gaze behavior through a short training session. The ANN finds the relationship between the gaze coordinates and the mouse cursor position based on the multilayer perceptron model. An embedded graphical interface is used during the training session to generate user profiles that make up these unique ANN configurations. The results with 12 subjects in test 1, which involved following a moving target, showed an average jitter reduction of 35%; the results with 9 subjects in test 2, which involved following the contour of a square object, showed an average jitter reduction of 53%. For both results, the outcomes led to trajectories that were significantly smoother and apt at reaching fixed or moving targets with relative ease and within a 5% error margin or deviation from desired trajectories. The positive effects of such jitter reduction are presented graphically for visual appreciation.
Balasubramanian, Sivaraman A; Pye, David C; Willcox, Mark D P
2013-03-01
Proteases, protease activity and inflammatory molecules in tears have been found to be relevant in the pathogenesis of keratoconus. We sought to determine the influence of eye rubbing on protease expression, protease activity and concentration of inflammatory molecules in tears. Basal tears were collected from normal volunteers before and after 60 seconds of experimental eye rubbing. The total amount of matrix metalloproteinase (MMP)-13 and inflammatory molecules interleukin (IL)-6 and tumour necrosis factor (TNF)-α in the tear samples were measured using specific enzyme-linked immunosorbent assays (ELISA). Tear collagenase activity was investigated using a specific activity assay. The concentrations of MMP-13 (51.9 ± 34.3 versus 63 ± 36.8 pg/ml, p = 0.006), IL-6 (1.24 ± 0.98 versus 2.02 ± 1.52 pg/ml, p = 0.004) and TNF-α (1.16 ± 0.74 versus 1.44 ± 0.66 pg/ml, p = 0.003) were significantly increased in normal subjects after eye rubbing. The experimental eye rub did not alter significantly the collagenase activity (5.02 ± 3 versus 7.50 ± 3.90 fluorescent intensity units, p = 0.14) of tears. Eye rubbing for 60 seconds increased the level of tear MMP-13, IL-6 and TNF-α in normal study subjects. This increase in protease, protease activity and inflammatory mediators in tears after eye rubbing may be exacerbated even further during persistent and forceful eye rubbing seen in people with keratoconus and this in turn may contribute to the progression of the disease. © 2013 The Authors. Clinical and Experimental Optometry © 2013 Optometrists Association Australia.
Functional anatomy and immunological interactions of ocular surface and adnexa.
Paulsen, Friedrich
2008-01-01
This chapter gives an overview about the structures and physiology of the ocular surface and its adnexa and focuses in a second part on the possible meaning of eye-associated lymphoid tissue (EALT) in a context with the development of dry eye. Sections deal with (1) anatomy of the ocular surface, lacrimal gland, eyelid and nasolacrimal ducts. (2) The meaning and importance of the lacrimal functional unit and the function of the mucosal innate immune system are briefly summarized. (3) Finally, the occurrence and the possible function of EALT is discussed with regard to tolerance induction and dry eye. The epithelial surface of the eye and its specialized glandular infoldings produce the components of the tear film, which include water, protective antimicrobials, cytokines, lipids as well as mucins and trefoil factor family (TFF) peptides. Antimicrobials, mucins and TFF peptides perform a number of essential functions which, collectively, provide protection of the ocular surface. Their production changes in cases of dry eye. The development of EALT is a common feature frequently occurring in symptomatically normal conjunctiva and nasolacrimal ducts. The production of antimicrobials, mucins and TFF peptides can be linked with cell signaling, tear film rheology, and antimicrobial defense at the ocular surface. Changes in the production of such peptides and proteins in cases of dry eye support the assumption that these peptides and proteins are involved in the pathophysiological events that occur at the ocular surface and lacrimal apparatus. Whether special types of bacteria, viruses, or other factors, e.g., immune deviation, are responsible for the development of EALT in humans requires further investigation in prospective and experimental studies.
Martin, Amy C; Thornton, J Derek; Liu, Jiewiu; Wang, XiaoFei; Zuo, Jian; Jablonski, Monica M; Chaum, Edward; Zindy, Frederique; Skapek, Stephen X
2004-10-01
Persistent hyperplastic primary vitreous (PHPV) is an idiopathic developmental eye disease associated with failed involution of the hyaloid vasculature. The present work addressed the pathogenesis of PHPV in a mouse model that replicates many aspects of the human disease. Ophthalmoscopic and histologic analyses documented pathologic processes in eyes of mice lacking the Arf gene compared with Ink4a-deficient and wild-type control animals. Immunohistochemical staining, in situ hybridization, and RT-PCR demonstrated the expression of relevant gene products. Arf gene expression was determined by in situ hybridization using wholemounts of wild-type mouse eyes and by immunofluorescence staining for green fluorescent protein (GFP) in Arf(+/GFP) heterozygous knock-in mouse eyes. Abnormalities in Arf(-/-) mice mimicked those found in patients with severe PHPV. The mice had microphthalmia; fibrovascular, retrolental tissue containing retinal pigment epithelial cells and remnants of the hyaloid vascular system; posterior lens capsule destruction with lens degeneration and opacity; and severe retinal dysplasia and detachment. Eyes of mice lacking the overlapping Ink4a gene were normal. Arf was selectively expressed in perivascular cells within the vitreous of the postnatal eye. Cells composing the retrolental mass in Arf(-/-) mice expressed the Arf promoter. The remnant hyaloid vessels expressed Flk-1. Its ligand, vascular endothelial growth factor (Vegf), was expressed in the retrolental tissue and the adjacent dysplastic neuroretina. Arf(-/-) mice have features that accurately mimic severe PHPV. In the HVS, Arf expression in perivascular cells may block their accumulation or repress Vegf expression to promote HVS involution and prevent PHPV.
Martin, Amy C.; Thornton, J. Derek; Liu, Jiewiu; Wang, XiaoFei; Zuo, Jian; Jablonski, Monica M.; Chaum, Edward; Zindy, Frederique; Skapek, Stephen X.
2006-01-01
Purpose Persistent hyperplastic primary vitreous (PHPV) is an idiopathic developmental eye disease associated with failed involution of the hyaloid vasculature. The present work addressed the pathogenesis of PHPV in a mouse model that replicates many aspects of the human disease. Methods Ophthalmoscopic and histologic analyses documented pathologic processes in eyes of mice lacking the Arf gene compared with Ink4a-deficient and wild-type control animals. Immunohistochemical staining, in situ hybridization, and RT-PCR demonstrated the expression of relevant gene products. Arf gene expression was determined by in situ hybridization using wholemounts of wild-type mouse eyes and by immunofluorescence staining for green fluores-cent protein (GFP) in Arf+/GFP heterozygous knock-in mouse eyes. Results Abnormalities in Arf−/− mice mimicked those found in patients with severe PHPV. The mice had microphthalmia; fibrovascular, retrolental tissue containing retinal pigment epithelial cells and remnants of the hyaloid vascular system; posterior lens capsule destruction with lens degeneration and opacity; and severe retinal dysplasia and detachment. Eyes of mice lacking the overlapping Ink4a gene were normal. Arf was selectively expressed in perivascular cells within the vitreous of the postnatal eye. Cells composing the retrolental mass in Arf−/− mice expressed the Arf promoter. The remnant hyaloid vessels expressed Flk-1. Its ligand, vascular endothelial growth factor (Vegf), was expressed in the retrolental tissue and the adjacent dysplastic neuroretina. Conclusions Arf−/− mice have features that accurately mimic severe PHPV. In the HVS, Arf expression in perivascular cells may block their accumulation or repress Vegf expression to promote HVS involution and prevent PHPV. PMID:15452040
Hahn, Paul; Migacz, Justin; O'Donnell, Rachelle; Day, Shelley; Lee, Annie; Lin, Phoebe; Vann, Robin; Kuo, Anthony; Fekrat, Sharon; Mruthyunjaya, Prithvi; Postel, Eric A; Izatt, Joseph A; Toth, Cynthia A
2013-01-01
The authors have recently developed a high-resolution microscope-integrated spectral domain optical coherence tomography (MIOCT) device designed to enable OCT acquisition simultaneous with surgical maneuvers. The purpose of this report is to describe translation of this device from preclinical testing into human intraoperative imaging. Before human imaging, surgical conditions were fully simulated for extensive preclinical MIOCT evaluation in a custom model eye system. Microscope-integrated spectral domain OCT images were then acquired in normal human volunteers and during vitreoretinal surgery in patients who consented to participate in a prospective institutional review board-approved study. Microscope-integrated spectral domain OCT images were obtained before and at pauses in surgical maneuvers and were compared based on predetermined diagnostic criteria to images obtained with a high-resolution spectral domain research handheld OCT system (HHOCT; Bioptigen, Inc) at the same time point. Cohorts of five consecutive patients were imaged. Successful end points were predefined, including ≥80% correlation in identification of pathology between MIOCT and HHOCT in ≥80% of the patients. Microscope-integrated spectral domain OCT was favorably evaluated by study surgeons and scrub nurses, all of whom responded that they would consider participating in human intraoperative imaging trials. The preclinical evaluation identified significant improvements that were made before MIOCT use during human surgery. The MIOCT transition into clinical human research was smooth. Microscope-integrated spectral domain OCT imaging in normal human volunteers demonstrated high resolution comparable to tabletop scanners. In the operating room, after an initial learning curve, surgeons successfully acquired human macular MIOCT images before and after surgical maneuvers. Microscope-integrated spectral domain OCT imaging confirmed preoperative diagnoses, such as full-thickness macular hole and vitreomacular traction, and demonstrated postsurgical changes in retinal morphology. Two cohorts of five patients were imaged. In the second cohort, the predefined end points were exceeded with ≥80% correlation between microscope-mounted OCT and HHOCT imaging in 100% of the patients. This report describes high-resolution MIOCT imaging using the prototype device in human eyes during vitreoretinal surgery, with successful achievement of predefined end points for imaging. Further refinements and investigations will be directed toward fully integrating MIOCT with vitreoretinal and other ocular surgery to image surgical maneuvers in real time.
Scanning laser polarimetry in eyes with exfoliation syndrome.
Dimopoulos, Antonios T; Katsanos, Andreas; Mikropoulos, Dimitrios G; Giannopoulos, Theodoros; Empeslidis, Theodoros; Teus, Miguel A; Holló, Gábor; Konstas, Anastasios G P
2013-01-01
To compare retinal nerve fiber layer thickness (RNFLT) of normotensive eyes with exfoliation syndrome (XFS) and healthy eyes. Sixty-four consecutive individuals with XFS and normal office-time intraocular pressure (IOP) and 72 consecutive healthy controls were prospectively enrolled for a cross-sectional analysis in this hospital-based observational study. The GDx-VCC parameters (temporal-superior-nasal-inferior-temporal [TSNIT] average, superior average, inferior average, TSNIT standard deviation (SD), and nerve fiber indicator [NFI]) were compared between groups. Correlation between various clinical parameters and RNFLT parameters was investigated with Spearman coefficient. The NFI, although within normal limits for both groups, was significantly greater in the XFS group compared to controls: the respective median and interquartile range (IQR) values were 25.1 (22.0-29.0) vs 15.0 (12.0-20.0), p<0.001. In the XFS group, all RNFLT values were significantly lower compared to controls (p<0.001). However, they were all within the normal clinical ranges for both groups: TSNIT average median (IQR): 52.8 (49.7-55.7) vs 56.0 (53.0-59.3) µm; superior average mean (SD): 62.3 (6.7) vs 68.8 (8.2) µm; inferior average mean (SD): 58.0 (7.2) vs 64.8 (7.7) µm, respectively. TSNIT SD was significantly lower in the XFS group, median (IQR): 18.1 (15.4-20.4) vs 21.0 (18.4-23.8), p<0.001. There was no systematic relationship between RNFLT and visual acuity, cup-to-disc ratio, IOP, central corneal thickness, Humphrey mean deviation, and pattern standard deviation in either group. Compared to control eyes, polarimetry-determined RNFLT was lower in XFS eyes with normal IOP. Therefore, close monitoring of RNFLT may facilitate early identification of those XFS eyes that convert to exfoliative glaucoma.
Tusler, Charlotte A; Good, Kathryn L; Maggs, David J; Zwingenberger, Allison L; Reilly, Christopher M
2017-05-01
To characterize grossly, histologically, and via computed tomography (CT) the appearance of intrascleral cartilage, bone, or both in domestic goats with otherwise normal eyes and to correlate this with age, sex, and breed. Sixty-eight domestic goats (89 eyes). Forty-nine formalin-fixed globes from 38 goats underwent high-resolution CT, and gross and light microscopic examination. An additional 40 eyes from 30 goats underwent light microscopy only. Age, breed, and sex of affected goats were retrieved from medical records. Considering all methods of evaluation collectively, cartilage was detected in 42% of eyes (44% of goats) and bone in 11% of eyes (12% of goats); bone was never seen without cartilage. Goats in which bone, cartilage, or both were detected ranged from 0.25 to 13 (median = 3.5) years of age, represented 11 of 12 breeds of the study population, and had a male:female ratio of 11:19. Bone was detected in the eyes of significantly more males (n = 8) than females (n = 2). No sex predilection was noted for cartilage alone. Histology revealed intrascleral chondrocyte-like cells, hyaline cartilage, and islands of lamellar bone. Some regions of bone had central, adipose-rich, marrow-like cavities. CT localized mineralized tissue as adjacent to or partially surrounding the optic nerve head. This is the first report of intrascleral bone or cartilage in a normal goat and of intrascleral bone in an otherwise normal mammal. The high prevalence of intrascleral cartilage and bone in this study suggests that this finding is normal and likely represents an adaptation in goats. © 2016 American College of Veterinary Ophthalmologists.
Toward statistical modeling of saccadic eye-movement and visual saliency.
Sun, Xiaoshuai; Yao, Hongxun; Ji, Rongrong; Liu, Xian-Ming
2014-11-01
In this paper, we present a unified statistical framework for modeling both saccadic eye movements and visual saliency. By analyzing the statistical properties of human eye fixations on natural images, we found that human attention is sparsely distributed and usually deployed to locations with abundant structural information. This observations inspired us to model saccadic behavior and visual saliency based on super-Gaussian component (SGC) analysis. Our model sequentially obtains SGC using projection pursuit, and generates eye movements by selecting the location with maximum SGC response. Besides human saccadic behavior simulation, we also demonstrated our superior effectiveness and robustness over state-of-the-arts by carrying out dense experiments on synthetic patterns and human eye fixation benchmarks. Multiple key issues in saliency modeling research, such as individual differences, the effects of scale and blur, are explored in this paper. Based on extensive qualitative and quantitative experimental results, we show promising potentials of statistical approaches for human behavior research.
Whitmore, S Scott; Wagner, Alex H; DeLuca, Adam P; Drack, Arlene V; Stone, Edwin M; Tucker, Budd A; Zeng, Shemin; Braun, Terry A; Mullins, Robert F; Scheetz, Todd E
2014-12-01
Proper spatial differentiation of retinal cell types is necessary for normal human vision. Many retinal diseases, such as Best disease and male germ cell associated kinase (MAK)-associated retinitis pigmentosa, preferentially affect distinct topographic regions of the retina. While much is known about the distribution of cell types in the retina, the distribution of molecular components across the posterior pole of the eye has not been well-studied. To investigate regional difference in molecular composition of ocular tissues, we assessed differential gene expression across the temporal, macular, and nasal retina and retinal pigment epithelium (RPE)/choroid of human eyes using RNA-Seq. RNA from temporal, macular, and nasal retina and RPE/choroid from four human donor eyes was extracted, poly-A selected, fragmented, and sequenced as 100 bp read pairs. Digital read files were mapped to the human genome and analyzed for differential expression using the Tuxedo software suite. Retina and RPE/choroid samples were clearly distinguishable at the transcriptome level. Numerous transcription factors were differentially expressed between regions of the retina and RPE/choroid. Photoreceptor-specific genes were enriched in the peripheral samples, while ganglion cell and amacrine cell genes were enriched in the macula. Within the RPE/choroid, RPE-specific genes were upregulated at the periphery while endothelium associated genes were upregulated in the macula. Consistent with previous studies, BEST1 expression was lower in macular than extramacular regions. The MAK gene was expressed at lower levels in macula than in extramacular regions, but did not exhibit a significant difference between nasal and temporal retina. The regional molecular distinction is greatest between macula and periphery and decreases between different peripheral regions within a tissue. Datasets such as these can be used to prioritize candidate genes for possible involvement in retinal diseases with regional phenotypes. Copyright © 2014 The Authors. Published by Elsevier Ltd.. All rights reserved.
Whitmore, S. Scott; Wagner, Alex H.; DeLuca, Adam P.; Drack, Arlene V.; Stone, Edwin M.; Tucker, Budd A.; Zeng, Shemin; Braun, Terry A.; Mullins, Robert F.; Scheetz, Todd E.
2014-01-01
Proper spatial differentiation of retinal cell types is necessary for normal human vision. Many retinal diseases, such as Best disease and male germ cell associated kinase (MAK)-associated retinitis pigmentosa, preferentially affect distinct topographic regions of the retina. While much is known about the distribution of cell-types in the retina, the distribution of molecular components across the posterior pole of the eye has not been well-studied. To investigate regional difference in molecular composition of ocular tissues, we assessed differential gene expression across the temporal, macular, and nasal retina and retinal pigment epithelium (RPE)/choroid of human eyes using RNA-Seq. RNA from temporal, macular, and nasal retina and RPE/choroid from four human donor eyes was extracted, poly-A selected, fragmented, and sequenced as 100 bp read pairs. Digital read files were mapped to the human genome and analyzed for differential expression using the Tuxedo software suite. Retina and RPE/choroid samples were clearly distinguishable at the transcriptome level. Numerous transcription factors were differentially expressed between regions of the retina and RPE/choroid. Photoreceptor-specific genes were enriched in the peripheral samples, while ganglion cell and amacrine cell genes were enriched in the macula. Within the RPE/choroid, RPE-specific genes were upregulated at the periphery while endothelium associated genes were upregulated in the macula. Consistent with previous studies, BEST1 expression was lower in macular than extramacular regions. The MAK gene was expressed at lower levels in macula than in extramacular regions, but did not exhibit a significant difference between nasal and temporal retina. The regional molecular distinction is greatest between macula and periphery and decreases between different peripheral regions within a tissue. Datasets such as these can be used to prioritize candidate genes for possible involvement in retinal diseases with regional phenotypes. PMID:25446321
Seko, Yuko; Azuma, Noriyuki; Yokoi, Tadashi; Kami, Daisuke; Ishii, Ryuga; Nishina, Sachiko; Toyoda, Masashi; Shimokawa, Hitoyata; Umezawa, Akihiro
2017-01-01
Purpose/Aim: We sought to identify the anteroposterior spatial gene expression hierarchy in the human sclera to develop a hypothesis for axial elongation and deformity of the eyeball. We analyzed the global gene expression of human scleral cells derived from distinct parts of the human infant sclera obtained from surgically enucleated eyes with retinoblastoma, using Affymetrix GeneChip oligonucleotide arrays, and compared, in particular, gene expression levels between the anterior and posterior parts of the sclera. The ages of three donors were 10M, 4M, and 1Y9M. K-means clustering analysis of gene expression revealed that expression levels of cartilage-associated genes such as COLXIA and ACAN increased from the anterior to the posterior part of the sclera. Microarray analyses and RT-PCR data showed that the expression levels of MGP, COLXIA, BMP4, and RARB were significantly higher in the posterior than in the anterior sclera of two independent infant eyes. Conversely, expression levels of WNT2, DKK2, GREM1, and HOXB2 were significantly higher in the anterior sclera. Among several Wnt-family genes examined, WNT2B was found to be expressed at a significantly higher level in the posterior sclera, and the reverse order was observed for WNT2. The results of luciferase reporter assays suggested that a GSK-3β inhibitor stimulated Wnt/β-catenin signaling particularly strongly in the posterior sclera. The expression pattern of RARB, a myopia-related gene, was similar in three independent eyes. Chondrogenic potential was higher and Wnt/β-catenin signaling was more potently activated by a GSK-3β inhibitor in the posterior than in the anterior part of the human infant sclera. Although the differences in the gene expression profiles between the anterior and posterior sclera might be involved only in normal growth processes, this anteroposterior hierarchy in the sclera might contribute to disorders involving abnormal elongation and deformity of the eyeball, including myopia.
[Study on the safety of blue light leak of LED].
Shen, Chong-Yu; Xu, Zheng; Zhao, Su-Ling; Huang, Qing-Yu
2014-02-01
In this paper, the blue light properties of LED illumination devices have been investigated. Against the status quo of China's LED lighting, we measured the spectrum component of LED lamps and analyzed the photobiological safety under the current domestic and international standards GB/T 20145-2006/CIE S009/E: 2002 and IEC62471: 2006 standards as well as CTL-0744_2009-laser resolution, which provides the reference to the manufacture of LED lighting lamps as well as related safety standards and laws. If the radiance intensity of blue light in LED is lower than 100 W x m(-2) x Sr(-1), there is no harm to human eyes. LEDs will not cause harm to human eyes under normal use, but we should pay attention to the protection of special populations (children), and make sure that they avoid looking at a light source for a long time. The research has found that the blue-rich lamps can affect the human rule of work and rest, and therefore, the LED lamps with color temperature below 4 000 K and color rendering index of 80 are suitable for indoor use. At the same time, the lamps with different parameters should be selected according to the different distances.
NASA Astrophysics Data System (ADS)
Yuan, Yuan; Fang, Tao; Sun, Min Yuan; Gao, Wei Nan; Zhang, Shuo; Bi, Yong
2018-07-01
Laser speckle is a major issue for laser projection displays. In various techniques of speckle reduction, speckle is quantified with a speckle contrast value. However, the measured speckle contrast is poorly suited for the subjective speckle perception of a human observer. Here, we investigate the characteristics of human eyes and propose a simplified optical transfer function of human eyes. Accordingly, two human-eye-modeled speckle measuring sets are configured. Based on the experimental set, an advanced electromagnetic micro-scanning mirror (EM-MSM) is exploited; which is of 6.5 mm in diameter and its half angle is 7.8° for a horizontal scan and 6.53° for a vertical scan. Finally, we quantitatively show that images generated with an EM-MSM exhibit superior quality. By providing human-eye-modeled speckle measuring instruments and an EM-MSM for speckle reduction, it has a promising promotion to laser projector development.
Imaging shear stress distribution and evaluating the stress concentration factor of the human eye
NASA Astrophysics Data System (ADS)
Joseph Antony, S.
2015-03-01
Healthy eyes are vital for a better quality of human life. Historically, for man-made materials, scientists and engineers use stress concentration factors to characterise the effects of structural non-homogeneities on their mechanical strength. However, such information is scarce for the human eye. Here we present the shear stress distribution profiles of a healthy human cornea surface in vivo using photo-stress analysis tomography, which is a non-intrusive and non-X-ray based method. The corneal birefringent retardation measured here is comparable to that of previous studies. Using this, we derive eye stress concentration factors and the directional alignment of major principal stress on the surface of the cornea. Similar to thermometers being used for monitoring the general health in humans, this report provides a foundation to characterise the shear stress carrying capacity of the cornea, and a potential bench mark for validating theoretical modelling of stresses in the human eye in future.
Goldenberg, David T.; Giblin, Frank J.; Cheng, Mei; Chintala, Shravan K.; Trese, Michael T.; Drenser, Kimberly A.; Ruby, Alan J.
2010-01-01
Purpose Intravitreal bevacizumab (Avastin) is frequently used for the treatment of age-related macular degeneration. Previous studies have demonstrated full thickness retinal penetration. Intravitreal recombinant microplasmin (MP) has been shown to successfully induce a posterior vitreous detachment (PVD) and vitreous liquefaction in animals. It has been suggested that a PVD may alter the retinal penetration of molecules in the vitreous cavity. The aim of this study was to compare bevacizumab (BV) retinal penetration in rabbit eyes with and without a MP-induced PVD. Methods Twelve adult rabbits were injected with 0.1 ml (0.4 mg) of MP into the vitreous cavity of one eye. One week later, the rabbits were injected with 0.05 ml (1.25 mg) of BV into both eyes. Both eyes of three rabbits each were harvested at 6, 12, 24, and 72 hours after the BV injection. Frozen retinal cross sections were prepared, and BV retinal penetration was evaluated with immunohistochemistry using a fluorescence-labeled antibody against BV. Two eyes from one rabbit were not injected with either agent and used as controls to compare the background autofluorescence. Peripapillary retinal sections were recorded with a digital camera, and intra-retinal BV fluorescence-labeled antibody was measured by qualitative photographic interpretation. Two additional rabbits received an intravitreal injection of 0.1 ml of MP in one eye. One week later, both eyes from each rabbit were enucleated and frozen retinal sections were prepared and analyzed with light microscopy to evaluate for histologic damage. Results Full thickness BV retinal penetration was observed throughout the retina in both eyes of each rabbit. All of the MP-injected eyes exhibited increased antibody labeling in retinas evaluated 6, 12, and 24 hours after BV injection when compared with the contralateral non-MP-injected eyes. By three days after BV injection, all eyes demonstrated decreased antibody labeling compared to earlier time periods. At three days, one rabbit showed increased antibody labeling in the retina of the non-MP-injected eye compared with the contralateral MP-injected eye, and two rabbits exhibited similar antibody labeling in both eyes. When compared with control eyes, light microscopy demonstrated normal retinal histologic findings in eyes injected only with microplasmin. Conclusions Increased BV retinal penetration is observed initially in eyes with a MP-induced PVD, and the mechanism is likely multifactorial. By three days, retinal penetration is similar in eyes with and without a PVD. Although it is difficult to directly extrapolate to humans, our study suggests a PVD may alter the retinal penetration of BV. PMID:21099453
NASA Astrophysics Data System (ADS)
Das, Nandan Kumar; Mukhopadhyay, Sabyasachi; Ghosh, Nirmalya; Chhablani, Jay; Richhariya, Ashutosh; Divakar Rao, Kompalli; Sahoo, Naba Kishore
2016-09-01
Optical coherence tomography (OCT) enables us to monitor alterations in the thickness of the retinal layer as disease progresses in the human retina. However, subtle morphological changes in the retinal layers due to early disease progression often may not lead to detectable alterations in the thickness. OCT images encode depth-dependent backscattered intensity distribution arising due to the depth distributions of the refractive index from tissue microstructures. Here, such depth-resolved refractive index variations of different retinal layers were analyzed using multifractal detrended fluctuation analysis, a special class of multiresolution analysis tools. The analysis extracted and quantified microstructural multifractal information encoded in normal as well as diseased human retinal OCT images acquired in vivo. Interestingly, different layers of the retina exhibited different degrees of multifractality in a particular retina, and the individual layers displayed consistent multifractal trends in healthy retinas of different human subjects. In the retinal layers of diabetic macular edema (DME) subjects, the change in multifractality manifested prominently near the boundary of the DME as compared to the normal retinal layers. The demonstrated ability to quantify depth-resolved information on multifractality encoded in OCT images appears promising for the early diagnosis of diseases of the human eye, which may also prove useful for detecting other types of tissue abnormalities from OCT images.
... larger than normal spleen Anemia Burning, itchy, or dry eyes Fainting Heart palpitations Joint pain Muscle weakness Problems ... problems with the nervous system; burning, itching, or dry eyes; swollen salivary glands; swollen lymph nodes in the ...
Eye movement-invariant representations in the human visual system.
Nishimoto, Shinji; Huth, Alexander G; Bilenko, Natalia Y; Gallant, Jack L
2017-01-01
During natural vision, humans make frequent eye movements but perceive a stable visual world. It is therefore likely that the human visual system contains representations of the visual world that are invariant to eye movements. Here we present an experiment designed to identify visual areas that might contain eye-movement-invariant representations. We used functional MRI to record brain activity from four human subjects who watched natural movies. In one condition subjects were required to fixate steadily, and in the other they were allowed to freely make voluntary eye movements. The movies used in each condition were identical. We reasoned that the brain activity recorded in a visual area that is invariant to eye movement should be similar under fixation and free viewing conditions. In contrast, activity in a visual area that is sensitive to eye movement should differ between fixation and free viewing. We therefore measured the similarity of brain activity across repeated presentations of the same movie within the fixation condition, and separately between the fixation and free viewing conditions. The ratio of these measures was used to determine which brain areas are most likely to contain eye movement-invariant representations. We found that voxels located in early visual areas are strongly affected by eye movements, while voxels in ventral temporal areas are only weakly affected by eye movements. These results suggest that the ventral temporal visual areas contain a stable representation of the visual world that is invariant to eye movements made during natural vision.
Deletion of OTX2 in neural ectoderm delays anterior pituitary development
Mortensen, Amanda H.; Schade, Vanessa; Lamonerie, Thomas; Camper, Sally A.
2015-01-01
OTX2 is a homeodomain transcription factor that is necessary for normal head development in mouse and man. Heterozygosity for loss-of-function alleles causes an incompletely penetrant, haploinsufficiency disorder. Affected individuals exhibit a spectrum of features that range from developmental defects in eye and/or pituitary development to acephaly. To investigate the mechanism underlying the pituitary defects, we used different cre lines to inactivate Otx2 in early head development and in the prospective anterior and posterior lobes. Mice homozygous for Otx2 deficiency in early head development and pituitary oral ectoderm exhibit craniofacial defects and pituitary gland dysmorphology, but normal pituitary cell specification. The morphological defects mimic those observed in humans and mice with OTX2 heterozygous mutations. Mice homozygous for Otx2 deficiency in the pituitary neural ectoderm exhibited altered patterning of gene expression and ablation of FGF signaling. The posterior pituitary lobe and stalk, which normally arise from neural ectoderm, were extremely hypoplastic. Otx2 expression was intact in Rathke's pouch, the precursor to the anterior lobe, but the anterior lobe was hypoplastic. The lack of FGF signaling from the neural ectoderm was sufficient to impair anterior lobe growth, but not the differentiation of hormone-producing cells. This study demonstrates that Otx2 expression in the neural ectoderm is important intrinsically for the development of the posterior lobe and pituitary stalk, and it has significant extrinsic effects on anterior pituitary growth. Otx2 expression early in head development is important for establishing normal craniofacial features including development of the brain, eyes and pituitary gland. PMID:25315894
Robinson, Paulette M; Smith, Tyler S; Patel, Dilan; Dave, Meera; Lewin, Alfred S; Pi, Liya; Scott, Edward W; Tuli, Sonal S; Schultz, Gregory S
2012-12-13
Connective tissue growth factor (CTGF) is a fibrogenic cytokine that is up-regulated by TGF-β and mediates most key fibrotic actions of TGF-β, including stimulation of synthesis of extracellular matrix and differentiation of fibroblasts into myofibroblasts. This study addresses the role of proteolytic processing of CTGF in human corneal fibroblasts (HCF) stimulated with TGF-β, normal ocular tissues and wounded corneas. Proteolytic processing of CTGF in HCF cultures, normal animal eyes, and excimer laser wounded rat corneas were examined by Western blot. The identity of a 21-kDa band was determined by tandem mass spectrometry, and possible alternative splice variants of CTGF were assessed by 5' Rapid Amplification of cDNA Ends (RACE). HCF stimulated by TGF-β contained full length 38-kDa CTGF and fragments of 25, 21, 18, and 13 kDa, while conditioned medium contained full length 38- and a 21-kDa fragment of CTGF that contained the middle "hinge" region of CTGF. Fragmentation of recombinant CTGF incubated in HCF extracts was blocked by the aspartate protease inhibitor, pepstatin. Normal mouse, rat, and rabbit whole eyes and rabbit ocular tissues contained abundant amounts of C-terminal 25- and 21-kDa fragments and trace amounts of 38-kDa CTGF, although no alternative transcripts were detected. All forms of CTGF (38, 25, and 21 kDa) were detected during healing of excimer ablated rat corneas, peaking on day 11. Proteolytic processing of 38-kDa CTGF occurs during corneal wound healing, which may have important implications in regulation of corneal scar formation.
Aldehyde dehydrogenase inhibition blocks mucosal fibrosis in human and mouse ocular scarring
Ahadome, Sarah D.; Abraham, David J.; Rayapureddi, Suryanarayana; Saw, Valerie P.; Saban, Daniel R.; Calder, Virginia L.; Norman, Jill T.; Ponticos, Markella; Daniels, Julie T.; Dart, John K.
2016-01-01
Mucous membrane pemphigoid (MMP) is a systemic mucosal scarring disease, commonly causing blindness, for which there is no antifibrotic therapy. Aldehyde dehydrogenase family 1 (ALDH1) is upregulated in both ocular MMP (OMMP) conjunctiva and cultured fibroblasts. Application of the ALDH metabolite, retinoic acid (RA), to normal human conjunctival fibroblasts in vitro induced a diseased phenotype. Conversely, application of ALDH inhibitors, including disulfiram, to OMMP fibroblasts in vitro restored their functionality to that of normal controls. ALDH1 is also upregulated in the mucosa of the mouse model of scarring allergic eye disease (AED), used here as a surrogate for OMMP, in which topical application of disulfiram decreased fibrosis in vivo. These data suggest that progressive scarring in OMMP results from ALDH/RA fibroblast autoregulation, that the ALDH1 subfamily has a central role in immune-mediated ocular mucosal scarring, and that ALDH inhibition with disulfiram is a potential and readily translatable antifibrotic therapy. PMID:27699226
NASA Technical Reports Server (NTRS)
Groleau, Nicolas; Frainier, Richard; Colombano, Silvano; Hazelton, Lyman; Szolovits, Peter
1993-01-01
This paper describes portions of a novel system called MARIKA (Model Analysis and Revision of Implicit Key Assumptions) to automatically revise a model of the normal human orientation system. The revision is based on analysis of discrepancies between experimental results and computer simulations. The discrepancies are calculated from qualitative analysis of quantitative simulations. The experimental and simulated time series are first discretized in time segments. Each segment is then approximated by linear combinations of simple shapes. The domain theory and knowledge are represented as a constraint network. Incompatibilities detected during constraint propagation within the network yield both parameter and structural model alterations. Interestingly, MARIKA diagnosed a data set from the Massachusetts Eye and Ear Infirmary Vestibular Laboratory as abnormal though the data was tagged as normal. Published results from other laboratories confirmed the finding. These encouraging results could lead to a useful clinical vestibular tool and to a scientific discovery system for space vestibular adaptation.
NASA Astrophysics Data System (ADS)
Donnelly, William J., III
2012-06-01
PURPOSE: To present a commercially available optical modeling software tool to assist the development of optical instrumentation and systems that utilize and/or integrate with the human eye. METHODS: A commercially available flexible eye modeling system is presented, the Advanced Human Eye Model (AHEM). AHEM is a module that the engineer can use to perform rapid development and test scenarios on systems that integrate with the eye. Methods include merging modeled systems initially developed outside of AHEM and performing a series of wizard-type operations that relieve the user from requiring an optometric or ophthalmic background to produce a complete eye inclusive system. Scenarios consist of retinal imaging of targets and sources through integrated systems. Uses include, but are not limited to, optimization, telescopes, microscopes, spectacles, contact and intraocular lenses, ocular aberrations, cataract simulation and scattering, and twin eye model (binocular) systems. RESULTS: Metrics, graphical data, and exportable CAD geometry are generated from the various modeling scenarios.
Action spectrum for melatonin regulation in humans: evidence for a novel circadian photoreceptor
NASA Technical Reports Server (NTRS)
Brainard, G. C.; Hanifin, J. P.; Greeson, J. M.; Byrne, B.; Glickman, G.; Gerner, E.; Rollag, M. D.
2001-01-01
The photopigment in the human eye that transduces light for circadian and neuroendocrine regulation, is unknown. The aim of this study was to establish an action spectrum for light-induced melatonin suppression that could help elucidate the ocular photoreceptor system for regulating the human pineal gland. Subjects (37 females, 35 males, mean age of 24.5 +/- 0.3 years) were healthy and had normal color vision. Full-field, monochromatic light exposures took place between 2:00 and 3:30 A.M. while subjects' pupils were dilated. Blood samples collected before and after light exposures were quantified for melatonin. Each subject was tested with at least seven different irradiances of one wavelength with a minimum of 1 week between each nighttime exposure. Nighttime melatonin suppression tests (n = 627) were completed with wavelengths from 420 to 600 nm. The data were fit to eight univariant, sigmoidal fluence-response curves (R(2) = 0.81-0.95). The action spectrum constructed from these data fit an opsin template (R(2) = 0.91), which identifies 446-477 nm as the most potent wavelength region providing circadian input for regulating melatonin secretion. The results suggest that, in humans, a single photopigment may be primarily responsible for melatonin suppression, and its peak absorbance appears to be distinct from that of rod and cone cell photopigments for vision. The data also suggest that this new photopigment is retinaldehyde based. These findings suggest that there is a novel opsin photopigment in the human eye that mediates circadian photoreception.
Diagnosing dry eye with dynamic-area high-speed videokeratoscopy
NASA Astrophysics Data System (ADS)
Alonso-Caneiro, David; Turuwhenua, Jason; Iskander, D. Robert; Collins, Michael J.
2011-07-01
Dry eye syndrome is one of the most commonly reported eye health conditions. Dynamic-area high-speed videokeratoscopy (DA-HSV) represents a promising alternative to the most invasive clinical methods for the assessment of the tear film surface quality (TFSQ), particularly as Placido-disk videokeratoscopy is both relatively inexpensive and widely used for corneal topography assessment. Hence, improving this technique to diagnose dry eye is of clinical significance and the aim of this work. First, a novel ray-tracing model is proposed that simulates the formation of a Placido image. This model shows the relationship between tear film topography changes and the obtained Placido image and serves as a benchmark for the assessment of indicators of the ring's regularity. Further, a novel block-feature TFSQ indicator is proposed for detecting dry eye from a series of DA-HSV measurements. The results of the new indicator evaluated on data from a retrospective clinical study, which contains 22 normal and 12 dry eyes, have shown a substantial improvement of the proposed technique to discriminate dry eye from normal tear film subjects. The best discrimination was obtained under suppressed blinking conditions. In conclusion, this work highlights the potential of the DA-HSV as a clinical tool to diagnose dry eye syndrome.
NASA Astrophysics Data System (ADS)
1985-01-01
A new invention by scientists who have copied the structure of a human eye will help replace a human telescope-watching astronomer with a robot. It will be possible to provide technical vision not only for robot astronomers but also for their industrial fellow robots. So far, an artificial eye with dimensions close to those of a human eye discerns only black-and-white images. But already the second model of the eye is to perceive colors as well. Polymers which are suited for the role of the coat of an eye, lens, and vitreous body were applied. The retina has been replaced with a bundle of the finest glass filaments through which light rays get onto photomultipliers. They can be positioned outside the artificial eye. The main thing is to prevent great losses in the light guide.
Hyder, Fahmeed; Herman, Peter; Bailey, Christopher J; Møller, Arne; Globinsky, Ronen; Fulbright, Robert K; Rothman, Douglas L; Gjedde, Albert
2016-05-01
Regionally variable rates of aerobic glycolysis in brain networks identified by resting-state functional magnetic resonance imaging (R-fMRI) imply regionally variable adenosine triphosphate (ATP) regeneration. When regional glucose utilization is not matched to oxygen delivery, affected regions have correspondingly variable rates of ATP and lactate production. We tested the extent to which aerobic glycolysis and oxidative phosphorylation power R-fMRI networks by measuring quantitative differences between the oxygen to glucose index (OGI) and the oxygen extraction fraction (OEF) as measured by positron emission tomography (PET) in normal human brain (resting awake, eyes closed). Regionally uniform and correlated OEF and OGI estimates prevailed, with network values that matched the gray matter means, regardless of size, location, and origin. The spatial agreement between oxygen delivery (OEF≈0.4) and glucose oxidation (OGI ≈ 5.3) suggests that no specific regions have preferentially high aerobic glycolysis and low oxidative phosphorylation rates, with globally optimal maximum ATP turnover rates (VATP ≈ 9.4 µmol/g/min), in good agreement with (31)P and (13)C magnetic resonance spectroscopy measurements. These results imply that the intrinsic network activity in healthy human brain powers the entire gray matter with ubiquitously high rates of glucose oxidation. Reports of departures from normal brain-wide homogeny of oxygen extraction fraction and oxygen to glucose index may be due to normalization artefacts from relative PET measurements. © The Author(s) 2016.
Uguccioni, Ginevra; Golmard, Jean-Louis; de Fontréaux, Alix Noël; Leu-Semenescu, Smaranda; Brion, Agnès; Arnulf, Isabelle
2013-05-01
Dreams enacted during sleepwalking or sleep terrors (SW/ST) may differ from those enacted during rapid eye movement sleep behavior disorder (RBD). Subjects completed aggression, depression, and anxiety questionnaires. The mentations associated with SW/ST and RBD behaviors were collected over their lifetime and on the morning after video polysomnography (PSG). The reports were analyzed for complexity, length, content, setting, bizarreness, and threat. Ninety-one percent of 32 subjects with SW/ST and 87.5% of 24 subjects with RBD remembered an enacted dream (121 dreams in a lifetime and 41 dreams recalled on the morning). These dreams were more complex and less bizarre, with a higher level of aggression in the RBD than in SW/ST subjects. In contrast, we found low aggression, anxiety, and depression scores during the daytime in both groups. As many as 70% of enacted dreams in SW/ST and 60% in RBD involved a threat, but there were more misfortunes and disasters in the SW/ST dreams and more human and animal aggressions in the RBD dreams. The response to these threats differed, as the sleepwalkers mostly fled from a disaster (and 25% fought back when attacked), while 75% of RBD subjects counterattacked when assaulted. The dreams setting included their bedrooms in 42% SW/ST dreams, though this finding was exceptional in the RBD dreams. Different threat simulations and modes of defense seem to play a role during dream-enacted behaviors (e.g., fleeing a disaster during SW/ST, counterattacking a human or animal assault during RBD), paralleling and exacerbating the differences observed between normal dreaming in nonrapid eye movement (NREM) vs rapid eye movement (REM) sleep. Copyright © 2013 Elsevier B.V. All rights reserved.
Priorities and trends in the study of proteins in eye research, 1924–2014
Semba, Richard D.; Lam, Maggie; Sun, Kai; Zhang, Pingbo; Schaumberg, Debra A.; Ferrucci, Luigi; Ping, Peipei; Van Eyk, Jennifer E.
2015-01-01
Purpose To identify the proteins that are relevant to eye research and develop assays for the study of a set of these proteins. Experimental Design We conducted a bibliometric analysis by merging gene lists for human and mouse from the National Center for Biotechnology Information FTP site and combining them with PubMed references that were retrieved with the search terms “eye”[MeSH Terms] OR “eye”[All Fields] OR “eyes”[All Fields]. Results For human and mouse eye studies, respectively, the total number of publications was 13,525 and 23,895, and the total number of proteins was 4,050 and 4,717. For proteins in human and mouse eye studies, respectively, 88.7% and 81.7% had five or fewer citations. The top fifty most intensively studied proteins for human and mouse eye studies were generally in the areas of photoreceptors and phototransduction, inflammation and angiogenesis, neurodevelopment, lens transparency, and cell cycle and cellular processes. We proposed selected reaction monitoring assays that were developed in silico for the top fifty most intensively studied proteins in human and mouse eye research. Conclusions and clinical relevance We conclude that scientists engaged in eye research tend to focus on the same proteins. Newer resources and tools in proteomics can expand the investigations to lesser-known proteins of the eye. PMID:26123431
Unilateral pigmentary degeneration of the retina associated with heterochromia iridis.
Grisanti, S; Diestelhorst, M; Lebek, J; Walter, P; Heimann, K
1998-12-01
For the past 5 years, a 56-year-old patient has been displaying monocular progressive pigmentary changes in the left eye. Heterochromy of the left eye has been known since childhood. The other eye is clinically and functionally normal. The patient was adopted and he has no children. Therefore, we have no family history. The patient was examined clinically and by means of electroretinography, electrooculography, perimetry, computer tomography, pulsatile ocular blood flow (POBF) measurement, serology and Doppler sonography. Electrophysiology displayed a considerable reduction of scotopic and photopic ERGs, a reduced dark-through, and a reduced light-rise in the left eye, whereas the fellow eye was normal. The visual field was limited to 5 deg around the fixation point, and a peripheral crescent-shaped arch encircled the temporal-inferior quadrant concomitant to the pigmentary changes. By computer tomography and Doppler sonography a vascular affection was excluded. The left eye displayed lower POBF values. All serological tests were found negative. The clinical picture and negative exclusion criteria indicate a unilateral retinitis pigmentosa. However, with regard to the literature an unequivocal diagnosis can only be made upon hereditary evidence.
Bilateral phacoemulsification and intraocular lens implantation in a great horned owl.
Carter, Renee T; Murphy, Christopher J; Stuhr, Charles M; Diehl, Kathryn A
2007-02-15
A great horned owl of estimated age < 1 year that was captured by wildlife rehabilitators was evaluated because of suspected cataracts. Nuclear and incomplete cortical cataracts were evident in both eyes. Ocular ultrasonography revealed no evidence of retinal detachment, and electroretinography revealed normal retinal function. For visual rehabilitation, cataract surgery was planned and intraocular lens design was determined on the basis of values obtained from the schematic eye, which is a mathematical model representing a normal eye for a species. Cataract surgery and intraocular lens placement were performed in both eyes. After surgery, refraction was within -0.75 diopters in the right eye and -0.25 diopters in the left eye. Visual rehabilitation was evident on the basis of improved tracking and feeding behavior, and the owl was eventually released into the wild. In raptors with substantial visual compromise, euthanasia or placement in a teaching facility is a typical outcome because release of such a bird is unacceptable. Successful intraocular lens implantation for visual rehabilitation and successful release into the wild are achievable.
Guo, Lei; Tao, Jun; Xia, Fan; Yang, Zhi; Ma, Xiaoli; Hua, Rui
2016-09-01
Amblyopia is a visual impairment that is attributed to either abnormal binocular interactions or visual deprivation. The retina and choroids have been shown to be involved in the development of amblyopia. The purpose of this study was to investigate the retinal and choroidal microstructural abnormalities of amblyopia using digital subtraction autofluorescence and split-spectrum amplitude-decorrelation angiography (SSADA) approaches. This prospective study included 44 eyes of 22 patients with unilateral amblyopia. All patients who received indirect ophthalmoscopy, combined depth imaging spectral domain optical coherence tomography (OCT), SSADA-OCT, and macular blue light (BL-) and near-infrared (NIR-) autofluorescences underwent pupil dilation. The subfoveal choroidal thickness (SFCT) was measured. BL- and NIR-autofluorescences were determined for all patients and used to generate subtraction images with ImageJ software. The superficial, deep layers of the retina, and inner choroid layer were required for SSADA-OCT. For the normal eyes, a regularly increasing signal was observed in the central macula based on the subtraction images. In contrast, a decreased signal for the central patch or a reduced peak was detected in 16 of 22 amblyopic eyes (72.7%). The mean SFCT of the amblyopic eyes was greater than that of the fellow normal eyes (399.25 ± 4.944 µm vs. 280.58 ± 6.491 µm, respectively, P < 0.05). SSADA-OCT revealed a normal choroidal capillary network in all fellow normal eyes. However, 18 of 22 amblyopic eyes (86.4%) exhibited a blurry choroidal capillary network, and 15 of 22 amblyopic eyes (68.2%) displayed a dark atrophic patch. This is the first report of amblyopia using SSADA-OCT and digital subtraction images of autofluorescence. The mechanistic relationship of a thicker choroid and choroidal capillary atrophy with amblyopia remains to be described. The digital subtraction image confirmed the changes in the microstructure of the amblyopic retina as a supplementary approach to detect the progression of amblyopia. Lasers Surg. Med. 48:660-667, 2016. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.
Nagasawa, Miho; Ogawa, Misato; Mogi, Kazutaka; Kikusui, Takefumi
2017-01-01
Dogs acquired unique cognitive abilities during domestication, which is thought to have contributed to the formation of the human-dog bond. In European breeds, but not in wolves, a dog's gazing behavior plays an important role in affiliative interactions with humans and stimulates oxytocin secretion in both humans and dogs, which suggests that this interspecies oxytocin and gaze-mediated bonding was also acquired during domestication. In this study, we investigated whether Japanese breeds, which are classified as ancient breeds and are relatively close to wolves genetically, establish a bond with their owners through gazing behavior. The subject dogs were treated with either oxytocin or saline before the starting of the behavioral testing. We also evaluated physiological changes in the owners during mutual gazing by analyzing their heart rate variability (HRV) and subsequent urinary oxytocin levels in both dogs and their owners. We found that oxytocin treatment enhanced the gazing behavior of Japanese dogs and increased their owners' urinary oxytocin levels, as was seen with European breeds; however, the measured durations of skin contact and proximity to their owners were relatively low. In the owners' HRV readings, inter-beat (R-R) intervals (RRI), the standard deviation of normal to normal inter-beat (R-R) intervals (SDNN), and the root mean square of successive heartbeat interval differences (RMSSD) were lower when the dogs were treated with oxytocin compared with saline. Furthermore, the owners of female dogs showed lower SDNN than the owners of male dogs. These results suggest that the owners of female Japanese dogs exhibit more tension during interactions, and apart from gazing behavior, the dogs may show sex differences in their interactions with humans as well. They also suggest that Japanese dogs use eye-gazing as an attachment behavior toward humans similar to European breeds; however, there is a disparity between the dog sexes when it comes to the owners' oxytocin secretion. Japanese dogs also showed different attachment behaviors from both European breeds and wolves, and they likely use additional strategies to substitute gaze when forming the human-dog bond.
A Theoretical Analysis of a New Polarimetric Optical Scheme for Glucose Sensing in the Human Eye
NASA Technical Reports Server (NTRS)
Rovati, Luigi L.; Boeckle, Stefan; Ansari, Rafat R.; Salzman, Jack A. (Technical Monitor)
2002-01-01
The challenging task of in vivo polarimetric glucose sensing is the identification and selection of a scheme to optically access the aqueous humor of the human eye. In this short communication an earlier approach of Cote et al. is theoretically compared with our new optical scheme. Simulations of the new scheme using the eye model of Navarro, suggest that the new optical geometry can overcome the limitations of the previous approach for in vivo measurements of glucose in a human eye.
Samadani, Uzma; Farooq, Sameer; Ritlop, Robert; Warren, Floyd; Reyes, Marleen; Lamm, Elizabeth; Alex, Anastasia; Nehrbass, Elena; Kolecki, Radek; Jureller, Michael; Schneider, Julia; Chen, Agnes; Shi, Chen; Mendhiratta, Neil; Huang, Jason H.; Qian, Meng; Kwak, Roy; Mikheev, Artem; Rusinek, Henry; George, Ajax; Fergus, Robert; Kondziolka, Douglas; Huang, Paul P.; Smith, R. Theodore
2015-01-01
OBJECT Automated eye movement tracking may provide clues to nervous system function at many levels. Spatial calibration of the eye tracking device requires the subject to have relatively intact ocular motility that implies function of cranial nerves (CNs) III (oculomotor), IV (trochlear), and VI (abducent) and their associated nuclei, along with the multiple regions of the brain imparting cognition and volition. The authors have developed a technique for eye tracking that uses temporal rather than spatial calibration, enabling detection of impaired ability to move the pupil relative to normal (neurologically healthy) control volunteers. This work was performed to demonstrate that this technique may detect CN palsies related to brain compression and to provide insight into how the technique may be of value for evaluating neuropathological conditions associated with CN palsy, such as hydrocephalus or acute mass effect. METHODS The authors recorded subjects’ eye movements by using an Eyelink 1000 eye tracker sampling at 500 Hz over 200 seconds while the subject viewed a music video playing inside an aperture on a computer monitor. The aperture moved in a rectangular pattern over a fixed time period. This technique was used to assess ocular motility in 157 neurologically healthy control subjects and 12 patients with either clinical CN III or VI palsy confirmed by neuro-ophthalmological examination, or surgically treatable pathological conditions potentially impacting these nerves. The authors compared the ratio of vertical to horizontal eye movement (height/width defined as aspect ratio) in normal and test subjects. RESULTS In 157 normal controls, the aspect ratio (height/width) for the left eye had a mean value ± SD of 1.0117 ± 0.0706. For the right eye, the aspect ratio had a mean of 1.0077 ± 0.0679 in these 157 subjects. There was no difference between sexes or ages. A patient with known CN VI palsy had a significantly increased aspect ratio (1.39), whereas 2 patients with known CN III palsy had significantly decreased ratios of 0.19 and 0.06, respectively. Three patients with surgically treatable pathological conditions impacting CN VI, such as infratentorial mass effect or hydrocephalus, had significantly increased ratios (1.84, 1.44, and 1.34, respectively) relative to normal controls, and 6 patients with supratentorial mass effect had significantly decreased ratios (0.27, 0.53, 0.62, 0.45, 0.49, and 0.41, respectively). These alterations in eye tracking all reverted to normal ranges after surgical treatment of underlying pathological conditions in these 9 neurosurgical cases. CONCLUSIONS This proof of concept series of cases suggests that the use of eye tracking to detect CN palsy while the patient watches television or its equivalent represents a new capacity for this technology. It may provide a new tool for the assessment of multiple CNS functions that can potentially be useful in the assessment of awake patients with elevated intracranial pressure from hydrocephalus or trauma. PMID:25495739
Samadani, Uzma; Farooq, Sameer; Ritlop, Robert; Warren, Floyd; Reyes, Marleen; Lamm, Elizabeth; Alex, Anastasia; Nehrbass, Elena; Kolecki, Radek; Jureller, Michael; Schneider, Julia; Chen, Agnes; Shi, Chen; Mendhiratta, Neil; Huang, Jason H; Qian, Meng; Kwak, Roy; Mikheev, Artem; Rusinek, Henry; George, Ajax; Fergus, Robert; Kondziolka, Douglas; Huang, Paul P; Smith, R Theodore
2015-03-01
Automated eye movement tracking may provide clues to nervous system function at many levels. Spatial calibration of the eye tracking device requires the subject to have relatively intact ocular motility that implies function of cranial nerves (CNs) III (oculomotor), IV (trochlear), and VI (abducent) and their associated nuclei, along with the multiple regions of the brain imparting cognition and volition. The authors have developed a technique for eye tracking that uses temporal rather than spatial calibration, enabling detection of impaired ability to move the pupil relative to normal (neurologically healthy) control volunteers. This work was performed to demonstrate that this technique may detect CN palsies related to brain compression and to provide insight into how the technique may be of value for evaluating neuropathological conditions associated with CN palsy, such as hydrocephalus or acute mass effect. The authors recorded subjects' eye movements by using an Eyelink 1000 eye tracker sampling at 500 Hz over 200 seconds while the subject viewed a music video playing inside an aperture on a computer monitor. The aperture moved in a rectangular pattern over a fixed time period. This technique was used to assess ocular motility in 157 neurologically healthy control subjects and 12 patients with either clinical CN III or VI palsy confirmed by neuro-ophthalmological examination, or surgically treatable pathological conditions potentially impacting these nerves. The authors compared the ratio of vertical to horizontal eye movement (height/width defined as aspect ratio) in normal and test subjects. In 157 normal controls, the aspect ratio (height/width) for the left eye had a mean value ± SD of 1.0117 ± 0.0706. For the right eye, the aspect ratio had a mean of 1.0077 ± 0.0679 in these 157 subjects. There was no difference between sexes or ages. A patient with known CN VI palsy had a significantly increased aspect ratio (1.39), whereas 2 patients with known CN III palsy had significantly decreased ratios of 0.19 and 0.06, respectively. Three patients with surgically treatable pathological conditions impacting CN VI, such as infratentorial mass effect or hydrocephalus, had significantly increased ratios (1.84, 1.44, and 1.34, respectively) relative to normal controls, and 6 patients with supratentorial mass effect had significantly decreased ratios (0.27, 0.53, 0.62, 0.45, 0.49, and 0.41, respectively). These alterations in eye tracking all reverted to normal ranges after surgical treatment of underlying pathological conditions in these 9 neurosurgical cases. This proof of concept series of cases suggests that the use of eye tracking to detect CN palsy while the patient watches television or its equivalent represents a new capacity for this technology. It may provide a new tool for the assessment of multiple CNS functions that can potentially be useful in the assessment of awake patients with elevated intracranial pressure from hydrocephalus or trauma.
Syringomyelia presenting with unilateral optic neuropathy: a case report.
Ngoo, Qi Zhe; Tai, Evelyn Li Min; Wan Hitam, Wan Hazabbah
2017-01-01
In this case report, we present two cases of syringomyelia with optic neuropathy. In Case 1, a 36-year-old Malay lady presented to our clinic with acute onset of blurring of vision in her left eye that she experienced since past 1 month. She was diagnosed with syringomyelia 12 years ago and was on conservative management. Her visual acuity was 6/6 in the right eye and counting fingers at 1 m in the left. There was a positive relative afferent pupillary defect in her left eye. Optic nerve functions of her left eye were reduced. Visual field showed a left inferior field defect. Her extraocular muscle movements were full. Magnetic resonance imaging of the brain and spine showed syringomyelia at the level of C2-C6 and T2-T9. Both of her optic nerves were normal. Her condition improved with intravenous and oral corticosteroids. In Case 2, a 44-year-old Malay lady presented to our clinic with a progressive central scotoma in her right eye that she experienced since past 1 month. She had previous history of recurrent episodes of weakness in both of her lower limbs from past 8 months. Visual acuity in her right and left eye was 6/9 and 6/6, respectively. The relative afferent pupillary defect in her right eye was positive. Optic nerve functions of her right eye were affected. Visual field showed a central scotoma in her right eye. Her extraocular muscle movements were full. Fundoscopy of her right eye showed a pale optic disc. Her left eye fundus was normal. Magnetic resonance imaging of the brain and spine showed syringomyelia at T3-T6. Both of her optic nerves were normal. A diagnosis of syringomyelia with right optic atrophy was performed. Her condition improved with intravenous and oral corticosteroids. Optic neuropathy is a rare neuro-ophthalmic manifestation in patients with syringomyelia. Prompt diagnosis and timely management are essential to avoid a poor visual outcome. Intravenous corticosteroids are beneficial in the treatment of early optic neuropathy in syringomyelia.
Acute Zonal Cone Photoreceptor Outer Segment Loss.
Aleman, Tomas S; Sandhu, Harpal S; Serrano, Leona W; Traband, Anastasia; Lau, Marisa K; Adamus, Grazyna; Avery, Robert A
2017-05-01
The diagnostic path presented narrows down the cause of acute vision loss to the cone photoreceptor outer segment and will refocus the search for the cause of similar currently idiopathic conditions. To describe the structural and functional associations found in a patient with acute zonal occult photoreceptor loss. A case report of an adolescent boy with acute visual field loss despite a normal fundus examination performed at a university teaching hospital. Results of a complete ophthalmic examination, full-field flash electroretinography (ERG) and multifocal ERG, light-adapted achromatic and 2-color dark-adapted perimetry, and microperimetry. Imaging was performed with spectral-domain optical coherence tomography (SD-OCT), near-infrared (NIR) and short-wavelength (SW) fundus autofluorescence (FAF), and NIR reflectance (REF). The patient was evaluated within a week of the onset of a scotoma in the nasal field of his left eye. Visual acuity was 20/20 OU, and color vision was normal in both eyes. Results of the fundus examination and of SW-FAF and NIR-FAF imaging were normal in both eyes, whereas NIR-REF imaging showed a region of hyporeflectance temporal to the fovea that corresponded with a dense relative scotoma noted on light-adapted static perimetry in the left eye. Loss in the photoreceptor outer segment detected by SD-OCT co-localized with an area of dense cone dysfunction detected on light-adapted perimetry and multifocal ERG but with near-normal rod-mediated vision according to results of 2-color dark-adapted perimetry. Full-field flash ERG findings were normal in both eyes. The outer nuclear layer and inner retinal thicknesses were normal. Localized, isolated cone dysfunction may represent the earliest photoreceptor abnormality or a distinct entity within the acute zonal occult outer retinopathy complex. Acute zonal occult outer retinopathy should be considered in patients with acute vision loss and abnormalities on NIR-REF imaging, especially if multimodal imaging supports an intact retinal pigment epithelium and inner retina but an abnormal photoreceptor outer segment.
Context-specific adaptation of pursuit initiation in humans
NASA Technical Reports Server (NTRS)
Takagi, M.; Abe, H.; Hasegawa, S.; Usui, T.; Hasebe, H.; Miki, A.; Zee, D. S.; Shelhauser, M. (Principal Investigator)
2000-01-01
PURPOSE: To determine if multiple states for the initiation of pursuit, as assessed by acceleration in the "open-loop" period, can be learned and gated by context. METHODS: Four normal subjects were studied. A modified step-ramp paradigm for horizontal pursuit was used to induce adaptation. In an increasing paradigm, target velocity doubled 230 msec after onset; in a decreasing paradigm, it was halved. In the first experiment, vertical eye position (+/-5 degrees ) was used as the context cue, and the training paradigm (increasing or decreasing) changed with vertical eye position. In the second experiment, with vertical position constant, when the target was red, training was decreasing, and when green, increasing. The average eye acceleration in the first 100 msec of tracking was the index of open-loop pursuit performance. RESULTS: With vertical position as the cue, pursuit adaptation differed between up and down gaze. In some cases, the direction of adaptation was in exact accord with the training stimuli. In others, acceleration increased or decreased for both up and down gaze but always in correct relative proportion to the training stimuli. In contrast, multiple adaptive states were not induced with color as the cue. CONCLUSIONS: Multiple values for the relationship between the average eye acceleration during the initiation of pursuit and target velocity could be learned and gated by context. Vertical position was an effective contextual cue but not target color, implying that useful contextual cues must be similar to those occurring naturally, for example, orbital position with eye muscle weakness.
Obata, Takayuki; Uemura, Koji; Nonaka, Hiroi; Tamura, Mitsuru; Tanada, Shuji; Ikehira, Hiroo
2006-01-01
To acquire high-resolution magnetic resonance (MR) images, we developed a new blinking artifact reduced pulse (BARP) sequence with a surface coil specialized for microscopic imaging (47 mm in diameter). To reduce eye movement, we ascertained that the subjects' eyes were kept open and fixated to the target in the 1.5-T MR gantry. To reduce motion artifacts from blinking, we inserted rest periods for blinking (1.5 s within every 5 s) during MR scanning (T2-weighted fast spin echo; repetition time, 5 s; echo time, 100 ms; echo train, 11; matrix, 256 x 128; field of view, 5 cm; 1-mm thickness x 30 slices). Three scans (100 s x 3) were performed for each normal subject, and they were added together after automatic adjustment for location to reduce quality loss caused by head motion. T2-weighted MR images were acquired with a high resolution and a high signal-to-noise ratio. Motion artifacts were reduced with BARP, as compared with those with random blinking. Intraocular structures such as the iris and ciliary muscles were clearly visualized. Because the whole eye can be covered with a 1-mm thickness by this method, three-dimensional maps can easily be generated from the obtained images. The application of BARP with a surface coil of the human eye might become a useful and widely adopted procedure for MR microimaging.
Hua, Rui; Yao, Kai; Xia, Fan; Li, Jun; Guo, Lei; Yang, Guoxing; Tao, Jun
2016-03-01
Chronic central serous chorioretinopathy (CSCR) is regarded as a type of severe diffuse retinal pigment epitheliopathy. There is an atrophic tract at level of retinal pigment epithelium (RPE) due to hyper-permeability of choroidal vessels, along with photoreceptor (PR) atrophy. Indocyanine green angiography (ICGA) is considered a gold standard for diagnosis. The purpose of this work is to investigate the hyper-fluorescent transitional bands (HFTB) between hypo-fluorescent and normal regions of the retina in the ultra-late phase of ICGA in CSCR. 26 chronic CSCR eyes and 12 relative normal eyes received spectral domain optical coherence tomography (SD-OCT), and ICGA at the 24th hour after indocyanine green (ICG) intravenous injection. In the ultra-late phase, images showed homogenous fluorescence in all normal eyes. On the contrary, geographical hypofluorescent lesions with atrophy of RPE was noted in 26 chronic CSCR eyes. Moreover, HFTB with intact RPE and disrupted PR was detected in 20 out of 26 chronic CSCR eyes (76.9%). The HFTB may indicate the early damage in chronic CSCR. Ultra-late ICGA can monitor not only metabolic status by endogenous melanin, but also membrane function in RPE by exogenous ICG molecule. © 2015 Wiley Periodicals, Inc.
Yang, Hongli; Thompson, Hilary; Roberts, Michael D.; Sigal, Ian A.; Downs, J. Crawford
2011-01-01
Purpose. To retest the hypothesis that monkey ONH connective tissues become hypercompliant in early experimental glaucoma (EEG), by using 3-D histomorphometric reconstructions, and to expand the characterization of EEG connective tissue deformation to nine EEG eyes. Methods. Trephinated ONH and peripapillary sclera from both eyes of nine monkeys that were perfusion fixed, with one normal eye at IOP 10 mm Hg and the other EEG eye at 10 (n = 3), 30 (n = 3), or 45 (n = 3) mm Hg were serial sectioned, 3-D reconstructed, 3-D delineated, and quantified with 3-D reconstruction techniques developed in prior studies by the authors. Overall, and for each monkey, intereye differences (EEG eye minus normal eye) for each parameter were calculated and compared by ANOVA. Hypercompliance in the EEG 30 and 45 eyes was assessed by ANOVA, and deformations in all nine EEG eyes were separately compared by region without regard for fixation IOP. Results. Hypercompliant deformation was not significant in the overall ANOVA, but was suggested in a subset of EEG 30/45 eyes. EEG eye deformations included posterior laminar deformation, neural canal expansion, lamina cribrosa thickening, and posterior (outward) bowing of the peripapillary sclera. Maximum posterior laminar deformation and scleral canal expansion co-localized to either the inferior nasal or superior temporal quadrants in the eyes with the least deformation and involved both quadrants in the eyes achieving the greatest deformation. Conclusions. The data suggest that, in monkey EEG, ONH connective tissue hypercompliance may occur only in a subset of eyes and that early ONH connective tissue deformation is maximized in the superior temporal and/or inferior nasal quadrants. PMID:20702834
Tear dynamics in healthy and dry eyes.
Cerretani, Colin F; Radke, C J
2014-06-01
Dry-eye disease, an increasingly prevalent ocular-surface disorder, significantly alters tear physiology. Understanding the basic physics of tear dynamics in healthy and dry eyes benefits both diagnosis and treatment of dry eye. We present a physiological-based model to describe tear dynamics during blinking. Tears are compartmentalized over the ocular surface; the blink cycle is divided into three repeating phases. Conservation laws quantify the tear volume and tear osmolarity of each compartment during each blink phase. Lacrimal-supply and tear-evaporation rates are varied to reveal the dependence of tear dynamics on dry-eye conditions, specifically tear osmolarity, tear volume, tear-turnover rate (TTR), and osmotic water flow. Predicted periodic-steady tear-meniscus osmolarity is 309 and 321 mOsM in normal and dry eyes, respectively. Tear osmolarity, volume, and TTR all match available clinical measurements. Osmotic water flow through the cornea and conjunctiva contribute 10 and 50% to the total tear supply in healthy and dry-eye conditions, respectively. TTR in aqueous-deficient dry eye (ADDE) is only half that in evaporative dry eye (EDE). The compartmental periodic-steady tear-dynamics model accurately predicts tear behavior in normal and dry eyes. Inclusion of osmotic water flow is crucial to match measured tear osmolarity. Tear-dynamics predictions corroborate the use of TTR as a clinical discriminator between ADDE and EDE. The proposed model is readily extended to predict the dynamics of aqueous solutes such as drugs or fluorescent tags.
Niechwiej-Szwedo, Ewa; Goltz, Herbert C; Chandrakumar, Manokaraananthan; Wong, Agnes M F
2014-11-11
To examine the effects of strabismic amblyopia and strabismus only, without amblyopia, on the temporal patterns of eye-hand coordination during both the planning and execution stages of visually-guided reaching. Forty-six adults (16 with strabismic amblyopia, 14 with strabismus only, and 16 visually normal) executed reach-to-touch movements toward targets presented randomly 5° or 10° to the left or right of central fixation. Viewing conditions were binocular, monocular viewing with the amblyopic eye, and monocular viewing with the fellow eye (dominant and nondominant viewing for participants without amblyopia). Temporal coordination between eye and hand movements was examined during reach planning (interval between the initiation of saccade and reaching, i.e., saccade-to-reach planning interval) and reach execution (interval between the initiation of saccade and reach peak velocity [PV], i.e., saccade-to-reach PV interval). The frequency and dynamics of secondary reach-related saccades were also examined. The temporal patterns of eye-hand coordination prior to reach initiation were comparable among participants with strabismic amblyopia, strabismus only, and visually normal adults. However, the reach acceleration phase of participants with strabismic amblyopia and those with strabismus only were longer following target fixation (saccade-to-reach PV interval) than that of visually normal participants (P < 0.05). This effect was evident under all viewing conditions. The saccade-to-reach planning interval and the saccade-to-reach PV interval were not significantly different among participants with amblyopia with different levels of acuity and stereo acuity loss. Participants with strabismic amblyopia and strabismus only initiated secondary reach-related saccades significantly more frequently than visually normal participants. The amplitude and peak velocity of these saccades were significantly greater during amblyopic eye viewing in participants with amblyopia who also had negative stereopsis. Adults with strabismic amblyopia and strabismus only showed an altered pattern of temporal eye-hand coordination during the reach acceleration phase, which might affect their ability to modify reach trajectory using early online control. Secondary reach-related saccades may provide a compensatory mechanism with which to facilitate the late online control process in order to ensure relatively good reaching performance during binocular and fellow eye viewing. Copyright 2014 The Association for Research in Vision and Ophthalmology, Inc.
6-Hydroxy dopamine does not affect lens-induced refractive errors but suppresses deprivation myopia.
Schaeffel, F; Hagel, G; Bartmann, M; Kohler, K; Zrenner, E
1994-01-01
Degradation of the retinal image by translucent occluders during postnatal development induces axial myopia in chickens, tree shrews and monkeys. Local visual deprivation produces myopia even in local regions of the eye and neither accommodation nor intact connection between the eye and the brain are necessary. Therefore, it is an important question whether a similar local-retinal pathway translating visual information into growth or stretch signals to the underlying sclera is acting to emmetropize the growing eye. It is not known until now whether occluder deprivation triggers similar eye growth (or scleral stretch) mechanisms that are also responsible for visual guidance of normal refractive development. We here report that, in chickens, 6-hydroxy dopamine suppresses deprivation-induced myopia but has no effect on the magnitude of changes in axial eye elongation that are induced by spectacle lenses. The result suggests that, in chickens with normal accommodation, two pharmacologically different feedback loops may be responsible for deprivation myopia and lens-induced refractive errors.
Acute shallowing of the anterior chamber.
Mapstone, R
1981-01-01
In aging eyes phenylephrine drops have no significant effect on the depth of the anterior chamber, whereas pilocarpine drops produce a significant shallowing. If both drugs are instilled simultaneously, a significantly greater decrease in anterior chamber depth occurs. The effect is seen in normal, glaucomatous, and hypertensive eyes, and in eyes with shallow anterior chambers. It did not occur in eyes that had had an iridectomy. During the course of a positive provocative test an acute reduction in anterior depth occurs which is reversed when the angle opens and pressure returns to normal levels. It is concluded that the depth of the anterior chamber is not a static dimension but that changes can occur which are rapid and transient. The mechanism of shallowing and deepening depends on an increase or a decrease in the pupil block force. It is a necessary consequence too that eyes with nonshallow anterior chambers can get closed-angle glaucoma and that this possibility cannot be detected by a conventional gonioscopic approach. PMID:6455153
... normal skin and hair Patches of missing skin color Many forms of albinism are associated with the following symptoms: Crossed eyes Light sensitivity Rapid eye movements Vision problems, or functional blindness Exams and Tests Genetic testing offers the most ...
Altered characteristics of balance control in obese older adults.
Melzer, Itshak; Oddsson, Lars I E
2016-01-01
Obesity is one of the most significant epidemiological trends of the last decades. Recently it was found that obese individuals show postural instability. Balance control mechanisms in obese older adults were less studied. Therefore we aimed to investigate the effect of obesity on balance control mechanisms in older adults. Parameters from Stabilogram-Diffusion Analysis (SDA) and measures from summary statistics of foot centre-of-pressure (COP) displacements along the anterior-posterior (AP) and mediolateral (ML) directions in eyes open and eyes closed conditions were used to characterize postural control in 22 obese (30-<35kg/m(2)), 26 overweight (25-<30kg/m(2)), and 18 normal weight subjects (18.5-<25kg/m(2)). Obese group subjects demonstrated significantly greater transition displacement, transition time interval, and short-term scaling exponent in the ML-direction compared with the normal weight group (eyes open and closed). In the AP-direction the obese group showed greater transition displacement (eyes open) and short-term scaling exponent (eyes open and closed). Average AP-COP and ML-COP ranges of COP sway were higher in the obese group compared with the normal weight group (eyes open and closed). This work indicates an altered postural control process in obese older adults. A greater sway displacement before closed-loop feedback mechanisms are called into play was seen in the ML direction that may lead to a higher risk of instability and fall events. Copyright © 2015 Asia Oceania Association for the Study of Obesity. Published by Elsevier Ltd. All rights reserved.
Effect of ultrasound radiation force on the choroid.
Silverman, Ronald H; Urs, Raksha; Lloyd, Harriet O
2013-01-10
While visualization of the retina and choroid has made great progress, functional imaging techniques have been lacking. Our aim was to utilize acoustic radiation force impulse (ARFI) response to probe functional properties of these tissues. A single element 18-MHz ultrasound transducer was focused upon the retina of the rabbit eye. The procedure was performed with the eye proptosed and with the eye seated normally in the orbit. The transducer was excited to emit ARFI over a 10-ms period with a 25% duty cycle. Phase resolved pulse/echo data were acquired before, during, and following ARFI. In the proptosed eye, ARFI exposure produced tissue displacements ranging from 0 to 10 μm, and an immediate increase in choroidal echo amplitude to over 6 dB, decaying to baseline after about 1 second. In the normally seated eye, ultrasound phase shifts consistent with flow were observed in the choroid, but enhanced backscatter following ARFI rarely occurred. ARFI-induced displacements of about 10 μm were observed at the choroidal margins. Larger displacements occurred within the choroid and in orbital tissues. We hypothesize that elevated intraocular pressure occurring during proptosis induced choroidal ischemia and that acoustic radiation force produced a transient local decompression and reperfusion. With the eye normally seated, choroidal flow was observed and little alteration in backscatter resulted from exposure. Clinical application of this technique may provide new insights into diseases characterized by altered choroidal hemodynamics, including maculopathies, diabetic retinopathy, and glaucoma.
Adenosine receptor distribution in Rhesus monkey ocular tissue.
Beach, Krista M; Hung, Li-Fang; Arumugam, Baskar; Smith, Earl L; Ostrin, Lisa A
2018-05-21
Adenosine receptor (ADOR) antagonists, such as 7-methylxanthine (7-MX), have been shown to slow myopia progression in humans and animal models. Adenosine receptors are found throughout the body, and regulate the release of neurotransmitters such as dopamine and glutamate. However, the role of adenosine in eye growth is unclear. Evidence suggests that 7-MX increases scleral collagen fibril diameter, hence preventing axial elongation. This study used immunohistochemistry (IHC) and reverse-transcription quantitative polymerase chain reaction (RT-qPCR) to examine the distribution of the four ADORs in the normal monkey eye to help elucidate potential mechanisms of action. Eyes were enucleated from six Rhesus monkeys. Anterior segments and eyecups were separated into components and flash-frozen for RNA extraction or fixed in 4% paraformaldehyde and processed for immunohistochemistry against ADORA1, ADORA2a, ADORA2b, and ADORA3. RNA was reverse-transcribed, and qPCR was performed using custom primers. Relative gene expression was calculated using the ΔΔCt method normalizing to liver expression, and statistical analysis was performed using Relative Expression Software Tool. ADORA1 immunostaining was highest in the iris sphincter muscle, trabecular meshwork, ciliary epithelium, and retinal nerve fiber layer. ADORA2a immunostaining was highest in the corneal epithelium, trabecular meshwork, ciliary epithelium, retinal nerve fiber layer, and scleral fibroblasts. ADORA2b immunostaining was highest in corneal basal epithelium, limbal stem cells, iris sphincter, ciliary muscle, ciliary epithelium, choroid, isolated retinal ganglion cells and scattered scleral fibroblasts. ADORA3 immunostaining was highest in the iris sphincter, ciliary muscle, ciliary epithelium, choroid, isolated retinal ganglion cells, and scleral fibroblasts. Compared to liver mRNA, ADORA1 mRNA was significantly higher in the brain, retina and choroid, and significantly lower in the iris/ciliary body. ADORA2a expression was higher in brain and retina, ADORA2b expression was higher in retina, and ADORA3 was higher in the choroid. In conclusion, immunohistochemistry and RT-qPCR indicated differential patterns of expression of the four adenosine receptors in the ocular tissues of the normal non-human primate. The presence of ADORs in scleral fibroblasts and the choroid may support mechanisms by which ADOR antagonists prevent myopia. The potential effects of ADOR inhibition on both anterior and posterior ocular structures warrant investigation. Copyright © 2018 Elsevier Ltd. All rights reserved.
Eye Absence Does Not Regulate Planarian Stem Cells during Eye Regeneration.
LoCascio, Samuel A; Lapan, Sylvain W; Reddien, Peter W
2017-02-27
Dividing cells called neoblasts contain pluripotent stem cells and drive planarian flatworm regeneration from diverse injuries. A long-standing question is whether neoblasts directly sense and respond to the identity of missing tissues during regeneration. We used the eye to investigate this question. Surprisingly, eye removal was neither sufficient nor necessary for neoblasts to increase eye progenitor production. Neoblasts normally increase eye progenitor production following decapitation, facilitating regeneration. Eye removal alone, however, did not induce this response. Eye regeneration following eye-specific resection resulted from homeostatic rates of eye progenitor production and less cell death in the regenerating eye. Conversely, large head injuries that left eyes intact increased eye progenitor production. Large injuries also non-specifically increased progenitor production for multiple uninjured tissues. We propose a model for eye regeneration in which eye tissue production by planarian stem cells is not directly regulated by the absence of the eye itself. Copyright © 2017 Elsevier Inc. All rights reserved.
Electrotactile and vibrotactile displays for sensory substitution systems
NASA Technical Reports Server (NTRS)
Kaczmarek, Kurt A.; Webster, John G.; Bach-Y-rita, Paul; Tompkins, Willis J.
1991-01-01
Sensory substitution systems provide their users with environmental information through a human sensory channel (eye, ear, or skin) different from that normally used or with the information processed in some useful way. The authors review the methods used to present visual, auditory, and modified tactile information to the skin and discuss present and potential future applications of sensory substitution, including tactile vision substitution (TVS), tactile auditory substitution, and remote tactile sensing or feedback (teletouch). The relevant sensory physiology of the skin, including the mechanisms of normal touch and the mechanisms and sensations associated with electrical stimulation of the skin using surface electrodes (electrotactile, or electrocutaneous, stimulation), is reviewed. The information-processing ability of the tactile sense and its relevance to sensory substitution is briefly summarized. The limitations of current tactile display technologies are discussed.
The Role of Face Familiarity in Eye Tracking of Faces by Individuals with Autism Spectrum Disorders
ERIC Educational Resources Information Center
Sterling, Lindsey; Dawson, Geraldine; Webb, Sara; Murias, Michael; Munson, Jeffrey; Panagiotides, Heracles; Aylward, Elizabeth
2008-01-01
It has been shown that individuals with autism spectrum disorders (ASD) demonstrate normal activation in the fusiform gyrus when viewing familiar, but not unfamiliar faces. The current study utilized eye tracking to investigate patterns of attention underlying familiar versus unfamiliar face processing in ASD. Eye movements of 18 typically…
21 CFR 524.1200b - Kanamycin ophthalmic aqueous solution.
Code of Federal Regulations, 2011 CFR
2011-04-01
...) of this chapter. (c) Conditions of use. It is indicated for use in dogs in various eye infections due..., removal of foreign bodies, and intraocular surgery. Instill a few drops into the affected eye every 3... least 48 hours after the eye appears normal. For use only by or on the order of a licensed veterinarian...
21 CFR 524.1200a - Kanamycin ophthalmic ointment.
Code of Federal Regulations, 2011 CFR
2011-04-01
... for use in dogs in various eye infections due to kanamycin sensitive bacteria. It is used treating... the affected eye three or four times daily or more frequently if deemed advisable. Treatment should be continued for at least 48 hours after the eye appears normal. For use only by or on the order of a licensed...
21 CFR 524.1200b - Kanamycin ophthalmic aqueous solution.
Code of Federal Regulations, 2010 CFR
2010-04-01
...) of this chapter. (c) Conditions of use. It is indicated for use in dogs in various eye infections due..., removal of foreign bodies, and intraocular surgery. Instill a few drops into the affected eye every 3... least 48 hours after the eye appears normal. For use only by or on the order of a licensed veterinarian...
21 CFR 524.1200a - Kanamycin ophthalmic ointment.
Code of Federal Regulations, 2010 CFR
2010-04-01
... for use in dogs in various eye infections due to kanamycin sensitive bacteria. It is used treating... the affected eye three or four times daily or more frequently if deemed advisable. Treatment should be continued for at least 48 hours after the eye appears normal. For use only by or on the order of a licensed...
Desseilles, Martin; Vu, Thanh Dang; Laureys, Steven; Peigneux, Philippe; Degueldre, Christian; Phillips, Christophe; Maquet, Pierre
2006-09-01
Rapid eye movement sleep (REMS) is associated with intense neuronal activity, rapid eye movements, muscular atonia and dreaming. Another important feature in REMS is the instability in autonomic, especially in cardiovascular regulation. The neural mechanisms underpinning the variability in heart rate (VHR) during REMS are not known in detail, especially in humans. During wakefulness, the right insula has frequently been reported as involved in cardiovascular regulation but this might not be the case during REMS. We aimed at characterizing the neural correlates of VHR during REMS as compared to wakefulness and to slow wave sleep (SWS), the other main component of human sleep, in normal young adults, based on the statistical analysis of a set of H(2)(15)O positron emission tomography (PET) sleep data acquired during SWS, REMS and wakefulness. The results showed that VHR correlated more tightly during REMS than during wakefulness with the rCBF in the right amygdaloid complex. Moreover, we assessed whether functional relationships between amygdala and any brain area changed depending the state of vigilance. Only the activity within in the insula was found to covary with the amygdala, significantly more tightly during wakefulness than during REMS in relation to the VHR. The functional connectivity between the amygdala and the insular cortex, two brain areas involved in cardiovascular regulation, differs significantly in REMS as compared to wakefulness. This suggests a functional reorganization of central cardiovascular regulation during REMS.
[Pharmacological profiles of latanoprost (Xalatan), a novel anti-glaucoma drug].
Nomura, S; Hashimoto, M
2000-05-01
Latanoprost is a novel prostaglandin F2 alpha (PGF2 alpha) derivative. Topically applied latanoprost into the glaucomatous monkey eyes lowered intraocular pressure (IOP). Latanoprost, however, failed to produce the hypotensive effect in either rabbit or cat eyes. This species difference may be attributed to its high selectivity for the FP receptor and differences in prostaglandin receptor subtypes existed in the eye amongst these species. In ligand binding studies with bovine corpus luteum cell membranes, the Kd value for the FP receptor of latanoprost was the same as that for PGF2 alpha, 2.8 nM. Latanoprost augmented uveoscleral outflow (Uv) in monkeys without affecting trabecular outflow or outflow facility like PGF2 alpha. Although the precise mechanism of the increase in Uv is not fully understood, it is suggested that a decrease in extracellular matrix components in ciliary muscle may contribute to the increase in Uv. On the other hand, an increase in blood flow at the optic nerve head and neuroprotective action in addition to the IOP lowering effect may contribute to the efficacy of latanoprost in glaucoma therapy. Only tolerable conjunctival hyperemia was seen in rabbits. A phase III clinical trial revealed latanoprost (0.005%) once daily produced sustained reduction of IOP in ocular hypertension or primary open-angle glaucoma patients to a greater extent than timolol did. Furthermore, the effects of latanoprost on aqueous humor dynamics in normal human volunteers were similar to those in monkeys, indicating that latanoprost lowers IOP by the increase in Uv in humans.
Clark, Robert A.
2015-01-01
Vertical fusional vergence (VFV) normally compensates for slight vertical heterophorias. We employed magnetic resonance imaging to clarify extraocular muscle contributions to VFV induced by monocular two-prism diopter (1.15°) base-up prism in 14 normal adults. Fusion during prism viewing requires monocular infraduction. Scans were repeated without prism, and with prism shifted contralaterally. Contractility indicated by morphometric indexes was separately analyzed in medial and lateral vertical rectus and superior oblique (SO) putative compartments, and superior and inferior horizontal rectus extraocular muscle putative compartments, but in the whole inferior oblique (IO). Images confirmed appropriate VFV that was implemented by the inferior rectus (IR) medial compartment contracting ipsilateral and relaxing contralateral to prism. There was no significant contractility in the IR lateral compartment. The superior but not inferior lateral rectus (LR) compartment contracted significantly in the prism viewing eye, but not contralateral to prism. The IO contracted ipsilateral but not contralateral to the prism. In the infraducting eye, the SO medial compartment relaxed significantly, while the lateral compartment was unchanged; contralateral to prism, the SO lateral compartment contracted, while the medial compartment was unchanged. There was no contractility in the superior or medial rectus muscles in either eye. There was no globe retraction. We conclude that the vertical component of VFV is primarily implemented by IR medial compartment contraction. Since appropriate vertical rotation is not directly implemented, or is opposed, by associated differential LR and SO compartmental activity, and IO contraction, these actions probably implement a torsional component of VFV. PMID:25589593
The multifocal electroretinogram in X-linked juvenile retinoschisis.
Huang, Shizhou; Wu, Dezheng; Jiang, Futian; Luo, Guangwei; Liang, Jiongji; Wen, Feng; Yu, Minzhong; Long, Shixian; Wu, Lezheng
2003-05-01
To measure and compare the multifocal electroretinography in normal control and X-linked juvenile retinoschisis, 13 cases (13 right eyes) of normal control and nine cases (17 eyes) of X-linked juvenile retinoschisis were measured with VERIS Science 4.0. Four cases (eight eyes) out of the nine retinoschisis cases were tested with Ganzfeld ERG at the same day. The results showed statistically significant difference of average response densities and latencies in six ring retinal regions between the normal control and retinoschisis. The trace array and 3-D topography of multifocal ERG showed multi-area amplitude decrease with absence or reduction of central peak amplitude in patients with retinoschisis. The P1/N1 ratio of multifocal ERG average response densities in six ring retinal regions was different from the b/a ratio of Ganzfeld ERG. The multifocal ERG and Ganzfeld ERG each had its advantage in the diagnosis of retinoschisis.
Mayhew, Jessica A; Gómez, Juan-Carlos
2015-08-01
Human eye morphology is considered unique among the primates in that humans possess larger width/height ratios (WHR), expose a greater amount of visible sclera (SSI; width of exposed eyeball/width of visible iris), and critically, have a white sclera due to a lack of pigmentation. White sclera in humans amplifies gaze direction, whereas the all-dark eyes of apes are hypothesized to conceal gaze from others. This study examines WHR and SSI in humans (N = 13) and gorillas (N = 85) engaged in direct and averted gazes and introduces a qualitative assessment of sclera color to evaluate variations in sclera pigmentation. The results confirm previous findings that humans possess a larger WHR than gorillas but indicate that humans and gorillas display similar amounts of visible sclera. Additionally, 72% (N = 124) of gorilla eyes in this sample deviated from the assumed all-dark eye condition. This questions whether gaze camouflage is the primary function of darkened sclera in non-human primates or whether other functional roles can be ascribed to the sclera, light or dark. We argue that white sclera evolved to amplify direct gazes in humans, which would have played a significant role in the development of ostensive communication, which is communication that both shows something and shows the intention to show something. We conclude that the horizontal elongation of the human eye, rather than sclera color, more reliably distinguishes human from great ape eyes, represented here by gorillas. © 2015 Wiley Periodicals, Inc.
Reading strategies in mild to moderate strabismic amblyopia: an eye movement investigation.
Kanonidou, Evgenia; Proudlock, Frank A; Gottlob, Irene
2010-07-01
PURPOSE. To investigate oculomotor strategies in strabismic amblyopia and evaluate abnormalities during monocular and binocular reading. METHODS. Eye movements were recorded with a head-mounted infrared video eye-tracker (250 Hz, <0.01 degrees resolution) in 20 strabismic amblyopes (mean age, 44.9 +/- 10.7 years) and 20 normal control subjects (mean age, 42.8 +/- 10.9 years) while they silently read paragraphs of text. Monocular reading comparisons were made between the amblyopic eye and the nondominant eye of control subjects and the nonamblyopic eye and the dominant eye of the control subjects. Binocular reading between the amblyopic and control subjects was also compared. RESULTS. Mean reading speed, number of progressive and regressive saccades per line, saccadic amplitude (of progressive saccades), and fixation duration were estimated. Inter- and intrasubject statistical comparisons were made. Reading speed was significantly slower in amblyopes than in control subjects during monocular reading with amblyopic (13.094 characters/s vs. 22.188 characters/s; P < 0.0001) and nonamblyopic eyes (16.241 characters/s vs. 22.349 characters/s, P < 0.0001), and binocularly (15.698 characters/s vs. 23.425 characters/s, P < 0.0001). In amblyopes, reading was significantly slower with the amblyopic eye than with the nonamblyopic eye in binocular viewing (P < 0.05). These differences were associated with significantly more regressive saccades and longer fixation durations, but not with changes in saccadic amplitudes. CONCLUSIONS. In strabismic amblyopia, reading is impaired, not only during monocular viewing with the amblyopic eye, but also with the nonamblyopic eye and binocularly, even though normal visual acuity pertains to the latter two conditions. The impaired reading performance is associated with differences in both the saccadic and fixational patterns, most likely as adaptation strategies to abnormal sensory experiences such as crowding and suppression.
Oizumi, Takuya; Laakso, Ilkka; Hirata, Akimasa; Fujiwara, Osamu; Watanabe, Soichi; Taki, Masao; Kojima, Masami; Sasaki, Hiroshi; Sasaki, Kazuyuki
2013-07-01
The eye is said to be one of the most sensitive organs to microwave heating. According to previous studies, the possibility of microwave-induced cataract formation has been experimentally investigated in rabbit and monkey eyes, but not for the human eye due to ethical reasons. In the present study, the temperature elevation in the lens, the skin around the eye and the core temperature of numerical human and rabbit models for far-field and near-field exposures at 2.45 GHz are investigated. The temperature elevations in the human and rabbit models were compared with the threshold temperatures for inducing cataracts, thermal pain in the skin and reversible health effects such as heat exhaustion or heat stroke. For plane-wave exposure, the core temperature elevation is shown to be essential both in the human and in the rabbit models as suggested in the international guidelines and standards. For localised exposure of the human eye, the temperature elevation of the skin was essential, and the lens temperature did not reach its threshold for thermal pain. On the other hand, the lens temperature elevation was found to be dominant for the rabbit eye.
Gondré-Lewis, Marjorie C; Gboluaje, Temitayo; Reid, Shaina N; Lin, Stephen; Wang, Paul; Green, William; Diogo, Rui; Fidélia-Lambert, Marie N; Herman, Mary M
2015-01-01
The study of inborn genetic errors can lend insight into mechanisms of normal human development and congenital malformations. Here, we present the first detailed comparison of cranial and neuro pathology in two exceedingly rare human individuals with cyclopia and alobar holoprosencephaly (HPE) in the presence and absence of aberrant chromosome 18 (aCh18). The aCh18 fetus contained one normal Ch18 and one with a pseudo-isodicentric duplication of chromosome 18q and partial deletion of 18p from 18p11.31 where the HPE gene, TGIF, resides, to the p terminus. In addition to synophthalmia, the aCh18 cyclopic malformations included a failure of induction of most of the telencephalon – closely approximating anencephaly, unchecked development of brain stem structures, near absence of the sphenoid bone and a malformed neurocranium and viscerocranium that constitute the median face. Although there was complete erasure of the olfactory and superior nasal structures, rudiments of nasal structures derived from the maxillary bone were evident, but with absent pharyngeal structures. The second non-aCh18 cyclopic fetus was initially classified as a true Cyclops, as it appeared to have a proboscis and one median eye with a single iris, but further analysis revealed two eye globes as expected for synophthalmic cyclopia. Furthermore, the proboscis was associated with the medial ethmoid ridge, consistent with an incomplete induction of these nasal structures, even as the nasal septum and paranasal sinuses were apparently developed. An important conclusion of this study is that it is the brain that predicts the overall configuration of the face, due to its influence on the development of surrounding skeletal structures. The present data using a combination of macroscopic, computed tomography (CT) and magnetic resonance imaging (MRI) techniques provide an unparalleled analysis on the extent of the effects of median defects, and insight into normal development and patterning of the brain, face and their skeletal support. PMID:26278930