Sample records for normal incidence reflectometry

  1. Normal-incidence reflectance of optimized W/B4C x-ray multilayers in the range 1.4 nm < λ < 2.4 nm

    NASA Astrophysics Data System (ADS)

    Windt, David L.; Gullikson, Eric M.; Walton, Christopher C.

    2002-12-01

    We have fabricated W/B4C multilayers having periods in the range d = 0.8-1.2 nm and measured their soft-x-ray performance near normal incidence in the wavelength range 1.4 < λ < 2.4 nm. By adjusting the fractional layer thickness of W we have produced structures having interface widths σ ~ 0.29 nm (i.e., as determined from normal-incidence reflectometry), thus having optimal soft-x-ray performance. We describe our results and discuss their implications, particularly with regard to the development of short-wavelength normal-incidence x-ray optics.

  2. Oblique incidence reflectometry: optical models and measurements using a side-viewing gradient index lens-based endoscopic imaging system

    NASA Astrophysics Data System (ADS)

    Wall, R. Andrew; Barton, Jennifer K.

    2014-06-01

    A side-viewing, 2.3-mm diameter oblique incidence reflectometry endoscope has been designed to obtain optical property measurements of turbid samples. Light from a single-mode fiber is relayed obliquely onto the tissue with a gradient index lens-based distal optics assembly and the resulting diffuse reflectance profile is imaged and collected with a 30,000 element, 0.72 mm clear aperture fiber bundle. Sampling the diffuse reflectance in two-dimensions allows for fitting of the reflected intensity profile to a well-known theoretical model, permitting the extraction of both absorption and reduced scattering coefficients of the tissue sample. Models and measurements of the endoscopic imaging system are presented in tissue phantoms and in vivo mouse colon, verifying the endoscope's capabilities to accurately measure effective attenuation coefficient and differentiate diseased from normal colon.

  3. Study of multilayered SiGe semiconductor structures by X-ray diffractometry, grazing-incidence X-ray reflectometry, and secondary-ion mass spectrometry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yunin, P. A., E-mail: yunin@ipmras.ru; Drozdov, Yu. N.; Drozdov, M. N.

    2013-12-15

    In this publication, we report the results of studying a multilayerd nonperiodic SiGe/Si structure by the methods of X-ray diffractometry, grazing-angle X-ray reflectometry, and secondary-ion mass spectrometry (SIMS). Special attention is paid to the processing of the component distribution profile using the SIMS method and to consideration of the most significant experimental distortions introduced by this method. A method for processing the measured composition distribution profile with subsequent consideration of the influence of matrix effects, variation in the etching rate, and remnants of ion sputtering is suggested. The results of such processing are compared with a structure model obtained uponmore » combined analysis of X-ray diffractometry and grazing-angle reflectometry data. Good agreement between the results is established. It is shown that the combined use of independent techniques makes it possible to improve the methods of secondary-ion mass spectrometry and grazing-incidence reflectometry as applied to an analysis of multilayered heteroepitaxial structures (to increase the accuracy and informativity of these methods)« less

  4. Multiple resolution chirp reflectometry for fault localization and diagnosis in a high voltage cable in automotive electronics

    NASA Astrophysics Data System (ADS)

    Chang, Seung Jin; Lee, Chun Ku; Shin, Yong-June; Park, Jin Bae

    2016-12-01

    A multiple chirp reflectometry system with a fault estimation process is proposed to obtain multiple resolution and to measure the degree of fault in a target cable. A multiple resolution algorithm has the ability to localize faults, regardless of fault location. The time delay information, which is derived from the normalized cross-correlation between the incident signal and bandpass filtered reflected signals, is converted to a fault location and cable length. The in-phase and quadrature components are obtained by lowpass filtering of the mixed signal of the incident signal and the reflected signal. Based on in-phase and quadrature components, the reflection coefficient is estimated by the proposed fault estimation process including the mixing and filtering procedure. Also, the measurement uncertainty for this experiment is analyzed according to the Guide to the Expression of Uncertainty in Measurement. To verify the performance of the proposed method, we conduct comparative experiments to detect and measure faults under different conditions. Considering the installation environment of the high voltage cable used in an actual vehicle, target cable length and fault position are designed. To simulate the degree of fault, the variety of termination impedance (10 Ω , 30 Ω , 50 Ω , and 1 \\text{k} Ω ) are used and estimated by the proposed method in this experiment. The proposed method demonstrates advantages in that it has multiple resolution to overcome the blind spot problem, and can assess the state of the fault.

  5. The Search for Nanobubbles by Using Specular and Off-Specular Neutron Reflectometry.

    PubMed

    Gutfreund, Philipp; Maccarini, Marco; Dennison, Andrew J C; Wolff, Max

    2016-09-06

    We apply specular and off-specular neutron reflection at the hydrophobic silicon/water interface to check for evidence of nanoscopic air bubbles whose presence is claimed after an ad hoc procedure of solvent exchange. Nanobubbles and/or a depletion layer at the hydrophobic/water interface have long been discussed and generated a plethora of controversial scientific results. By combining neutron reflectometry (NR), off-specular reflectometry (OSS), and grazing incidence small angle neutron scattering (GISANS), we studied the interface between hydrophobized silicon and heavy water before and after saturation with nitrogen gas. Our specular reflectometry results can be interpreted by assuming a submolecular sized depletion layer and the off-specular measurements show no change with nitrogen super saturated water. This picture is consistent with the assumption that, following the solvent exchange, no additional nanobubbles are introduced at significant concentrations (if present at all). Furthermore, we discuss the results in terms of the maximum surface coverage of nanobubbles that could be present on the hydrophobic surface compatibly with the sensitivity limit of these techniques.

  6. Sensitivity analysis for oblique incidence reflectometry using Monte Carlo simulations.

    PubMed

    Kamran, Faisal; Andersen, Peter E

    2015-08-10

    Oblique incidence reflectometry has developed into an effective, noncontact, and noninvasive measurement technology for the quantification of both the reduced scattering and absorption coefficients of a sample. The optical properties are deduced by analyzing only the shape of the reflectance profiles. This article presents a sensitivity analysis of the technique in turbid media. Monte Carlo simulations are used to investigate the technique and its potential to distinguish the small changes between different levels of scattering. We present various regions of the dynamic range of optical properties in which system demands vary to be able to detect subtle changes in the structure of the medium, translated as measured optical properties. Effects of variation in anisotropy are discussed and results presented. Finally, experimental data of milk products with different fat content are considered as examples for comparison.

  7. Internal structure of copper(II)-phthalocyanine thin films on SiO2/Si substrates investigated by grazing incidence x-ray reflectometry

    NASA Astrophysics Data System (ADS)

    Brieva, A. C.; Jenkins, T. E.; Jones, D. G.; Strössner, F.; Evans, D. A.; Clark, G. F.

    2006-04-01

    The internal structure of copper(II)-phthalocyanine (CuPc) thin films grown on SiO2/Si by organic molecular beam deposition has been studied by grazing incidence x-ray reflectometry (GIXR) and atomic force microscopy. The electronic density profile is consistent with a structure formed by successive monolayers of molecules in the α form with the b axis lying in the substrate surface plane. The authors present an electronic density profile model of CuPc films grown on SiO2/Si. The excellent agreement between the model and experimental data allows postdeposition monitoring of the internal structure of the CuPc films with the nondestructive GIXR technique, providing a tool for accurate control of CuPc growth on silicon-based substrates. In addition, since the experiments have been carried out ex situ, they show that these structures can endure ambient conditions.

  8. Using Neutron Reflectometry to Discern the Structure of Fibrinogen Adsorption at the Stainless Steel/Aqueous Interface.

    PubMed

    Wood, Mary H; Browning, Kathryn L; Barker, Robert D; Clarke, Stuart M

    2016-06-23

    Neutron reflectometry has been successfully used to study adsorption on a stainless steel surface by means of depositing a thin steel film on silicon. The film was characterized using XPS (X-ray photoelectron spectroscopy), TOF-SIMS (time-of-flight secondary ion mass spectrometry), and GIXRD (grazing incidence X-ray diffraction), demonstrating the retention both of the austenitic phase and of the required composition for 316L stainless steel. The adsorption of fibrinogen from a physiologically-relevant solution onto the steel surface was studied using neutron reflectometry and QCM (quartz crystal microbalance) and compared to that on a deposited chromium oxide surface. It was found that the protein forms an irreversibly bound layer at low concentrations, with maximum protein concentration a distance of around 20 Å from the surface. Evidence for a further diffuse reversibly-bound layer forming at higher concentrations was also observed. Both the structure of the layer revealed by the neutron reflectometry data and the high water retention predicted by the QCM data suggest that there is a significant extent of protein unfolding upon adsorption. A lower extent of adsorption was seen on the chromium surfaces, although the adsorbed layer structures were similar, suggesting comparable adsorption mechanisms.

  9. Viscoelastic assessment of anal canal function using acoustic reflectometry: a clinically useful technique.

    PubMed

    Mitchell, Peter J; Klarskov, Niels; Telford, Karen J; Hosker, Gordon L; Lose, Gunnar; Kiff, Edward S

    2012-02-01

    Anal acoustic reflectometry is a new reproducible technique that allows a viscoelastic assessment of anal canal function. Five new variables reflecting anal canal function are measured: the opening and closing pressure, opening and closing elastance, and hysteresis. The aim of this study was to assess whether the parameters measured in anal acoustic reflectometry are clinically valid between continent and fecally incontinent subjects. This was an age- and sex-matched study of continent and incontinent women. The study was conducted at a university teaching hospital. One hundred women (50 with fecal incontinence and 50 with normal bowel control) were included in the study. Subjects were age matched to within 5 years. Parameters measured with anal acoustic reflectometry and manometry were compared between incontinent and continent groups using a paired t test. Diagnostic accuracy was assessed by the use of receiver operator characteristic curves. Four of the 5 anal acoustic reflectometry parameters at rest were significantly different between continent and incontinent women (eg, opening pressure in fecally incontinent subjects was 31.6 vs 51.5 cm H2O in continent subjects, p = 0.0001). Both anal acoustic reflectometry parameters of squeeze opening pressure and squeeze opening elastance were significantly reduced in the incontinent women compared with continent women (50 vs 99.1 cm H2O, p = 0.0001 and 1.48 vs 1.83 cm H2O/mm, p = 0.012). In terms of diagnostic accuracy, opening pressure at rest measured by reflectometry was significantly superior in discriminating between continent and incontinent women in comparison with resting pressure measured with manometry (p = 0.009). Anal acoustic reflectometry is a new, clinically valid technique in the assessment of continent and incontinent subjects. This technique, which assesses the response of the anal canal to distension and relaxation, provides a detailed viscoelastic assessment of anal canal function. This technique may not only aid the investigation of fecally incontinent subjects, but it may also improve our understanding of anal canal physiology during both the process of defecation and maintenance of continence.

  10. Crystalisation of aqueous ferrofluids at the free liquid interface investigated by specular and off-specular x-ray reflectometry

    NASA Astrophysics Data System (ADS)

    Gapon, I. V.; Petrenko, V. I.; Soltwedel, O.; Khaydukov, Yu N.; Kubovcikova, M.; Kopcansky, P.; Bulavin, L. A.; Avdeev, M. V.

    2018-03-01

    Structural organization of nanoparticles from aqueous ferrofluids on free liquid surface was studied by X-ray reflectometry. The observed layered structure at interface is associated with the evaporation of the solvent. By orienting an external magnetic during evaporation of the aqueos ferrofluids their structural organization can be manipulated. For a magnetic field applied perpendicular to the surface a more pronounced ordering along the surface normal is observed as in the case of a parallel field. Independent on the orientation of the magantic field a ∼ 20 μm thick surface layer of depleted nanoparticle concentration is found at the interface.

  11. Ion polished Cr/Sc attosecond multilayer mirrors for high water window reflectivity

    DOE PAGES

    Guggenmos, Alexander; Radünz, Stefan; Rauhut, Roman; ...

    2014-01-20

    Recent advances in the development of attosecond soft X-ray sources ranging into the water window spectral range, between the 1s states of carbon and oxygen (284 eV–543 eV), are also driving the development of suited broadband multilayer optics for steering and shaping attosecond pulses. The relatively low intensity of current High Harmonic Generation (HHG) soft X-ray sources calls for an efficient use of photons, thus the development of low-loss multilayer optics is of uttermost importance. Here, we report about the realization of broadband Cr/Sc attosecond multilayer mirrors with nearly atomically smooth interfaces by an optimized ion beam deposition and assistedmore » interface polishing process. This yields to our knowledge highest multilayer mirror reflectivity at 300 eV near normal incidence. The results are verified by transmission electron microscopy (TEM) and soft/hard X-ray reflectometry.« less

  12. Ion polished Cr/Sc attosecond multilayer mirrors for high water window reflectivity

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Guggenmos, Alexander; Radünz, Stefan; Rauhut, Roman

    Recent advances in the development of attosecond soft X-ray sources ranging into the water window spectral range, between the 1s states of carbon and oxygen (284 eV–543 eV), are also driving the development of suited broadband multilayer optics for steering and shaping attosecond pulses. The relatively low intensity of current High Harmonic Generation (HHG) soft X-ray sources calls for an efficient use of photons, thus the development of low-loss multilayer optics is of uttermost importance. Here, we report about the realization of broadband Cr/Sc attosecond multilayer mirrors with nearly atomically smooth interfaces by an optimized ion beam deposition and assistedmore » interface polishing process. This yields to our knowledge highest multilayer mirror reflectivity at 300 eV near normal incidence. The results are verified by transmission electron microscopy (TEM) and soft/hard X-ray reflectometry.« less

  13. Cr/B 4C multilayer mirrors: Study of interfaces and X-ray reflectance

    DOE PAGES

    Burcklen, C.; Soufli, R.; Gullikson, E.; ...

    2016-03-24

    Here, we present an experimental study of the effect of layer interfaces on the x-ray reflectance in Cr/B 4C multilayer interference coatings with layer thicknesses ranging from 0.7 nm to 5.4 nm. The multilayers were deposited by magnetron sputtering and by ion beam sputtering. Grazing incidence x-ray reflectometry, soft x-ray reflectometry, and transmission electron microscopy reveal asymmetric multilayer structures with a larger B 4C-on-Cr interface, which we modeled with a 1–1.5 nm thick interfacial layer. Reflectance measurements in the vicinity of the Cr L 2,3 absorption edge demonstrate fine structure that is not predicted by simulations using the currently tabulatedmore » refractive index (optical constants) values for Cr.« less

  14. X-Ray Reflectometry of DMPS Monolayers on a Water Substrate

    NASA Astrophysics Data System (ADS)

    Tikhonov, A. M.; Asadchikov, V. E.; Volkov, Yu. O.; Roshchin, B. S.; Ermakov, Yu. A.

    2017-12-01

    The molecular structure of dimyristoyl phosphatidylserine (DMPS) monolayers on a water substrate in different phase states has been investigated by X-ray reflectometry with a photon energy of 8 keV. According to the experimental data, the transition from a two-dimensional expanded liquid state to a solid gel state (liquid crystal) accompanied by the ordering of the hydrocarbon tails C14H27 of the DMPS molecule occurs in the monolayer as the surface pressure rises. The monolayer thickness is 20 ± 3 and 28 ± 2 Å in the liquid and solid phases, respectively, with the deflection angle of the molecular tail axis from the normal to the surface in the gel phase being 26° ± 8°. At least a twofold decrease in the degree of hydration of the polar lipid groups also occurs under two-dimensional monolayer compression. The reflectometry data have been analyzed using two approaches: under the assumption about the presence of two layers with different electron densities in the monolayer and without any assumptions about the transverse surface structure. Both approaches demonstrate satisfactory agreement between themselves in describing the experimental results.

  15. Synthetic Microwave Imaging Reflectometry diagnostic using 3D FDTD Simulations

    NASA Astrophysics Data System (ADS)

    Kruger, Scott; Jenkins, Thomas; Smithe, David; King, Jacob; Nimrod Team Team

    2017-10-01

    Microwave Imaging Reflectometry (MIR) has become a standard diagnostic for understanding tokamak edge perturbations, including the edge harmonic oscillations in QH mode operation. These long-wavelength perturbations are larger than the normal turbulent fluctuation levels and thus normal analysis of synthetic signals become more difficult. To investigate, we construct a synthetic MIR diagnostic for exploring density fluctuation amplitudes in the tokamak plasma edge by using the three-dimensional, full-wave FDTD code Vorpal. The source microwave beam for the diagnostic is generated and refelected at the cutoff surface that is distorted by 2D density fluctuations in the edge plasma. Synthetic imaging optics at the detector can be used to understand the fluctuation and background density profiles. We apply the diagnostic to understand the fluctuations in edge plasma density during QH-mode activity in the DIII-D tokamak, as modeled by the NIMROD code. This work was funded under DOE Grant Number DE-FC02-08ER54972.

  16. Basic analysis of reflectometry data software package for the analysis of multilayered structures according to reflectometry data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Astaf'ev, S. B., E-mail: bard@ns.crys.ras.ru; Shchedrin, B. M.; Yanusova, L. G.

    2012-01-15

    The main principles of developing the Basic Analysis of Reflectometry Data (BARD) software package, which is aimed at obtaining a unified (standardized) tool for analyzing the structure of thin multilayer films and nanostructures of different nature based on reflectometry data, are considered. This software package contains both traditionally used procedures for processing reflectometry data and the authors' original developments on the basis of new methods for carrying out and analyzing reflectometry experiments. The structure of the package, its functional possibilities, examples of application, and prospects of development are reviewed.

  17. Fused oblique incidence reflectometry and confocal fluorescence microscopy

    NASA Astrophysics Data System (ADS)

    Risi, Matthew D.; Rouse, Andrew R.; Gmitro, Arthur F.

    2011-03-01

    Confocal microendoscopy provides real-time high resolution cellular level images via a minimally invasive procedure, but relies on exogenous fluorophores, has a relatively limited penetration depth (100 μm) and field of view (700 μm), and produces a high rate of detailed information to the user. A new catheter based multi-modal system has been designed that combines confocal imaging and oblique incidence reflectometry (OIR), which is a non-invasive method capable of rapidly extracting tissue absorption, μa, and reduced scattering, μ's, spectra from tissue. The system builds on previous developments of a custom slit-scan multi-spectral confocal microendoscope and is designed to rapidly switch between diffuse spectroscopy and confocal fluorescence imaging modes of operation. An experimental proof-of-principle catheter has been developed that consists of a fiber bundle for traditional confocal fluorescence imaging and a single OIR source fiber which is manually redirected at +/- 26 degrees. Diffusely scattered light from each orientation of the source fiber is collected via the fiber bundle, with a frame of data representing spectra collected at a range of distances from the OIR source point. Initial results with intralipid phantoms show good agreement to published data over the 550-650 nm spectral range. We successfully imaged and measured the optical properties of rodent cardiac muscle.

  18. Enhancement of soft X-ray reflectivity and interface stability in nitridated Pd/Y multilayer mirrors.

    PubMed

    Xu, Dechao; Huang, Qiushi; Wang, Yiwen; Li, Pin; Wen, Mingwu; Jonnard, Philippe; Giglia, Angelo; Kozhevnikov, Igor V; Wang, Kun; Zhang, Zhong; Wang, Zhanshan

    2015-12-28

    Pd/Y multilayer mirrors operating in the soft X-ray region are characterized by a high theoretical reflectance, reaching 65% at normal incidence in the 8-12 nm wavelength range. However, a severe intermixing of neighboring Pd and Y layers results in an almost total disappearance of the interfaces inside the multilayer structures fabricated by direct current magnetron sputtering and thus a dramatic reflectivity decrease. Based on grazing incidence X-ray reflectometry and X-ray photoelectron spectroscopy, we demonstrate that the stability of the interfaces in Pd/Y multilayer structures can be essentially improved by adding a small amount of nitrogen (4-8%) to the working gas (Ar). High resolution transmission electron microscopy shows that the interlayer width is only 0.9 nm and 0.6 nm for Y(N)-on-Pd(N) and Pd(N)-on-Y(N) interfaces, respectively. A well-defined crystalline texture of YN (200) is observed on the electron diffraction pattern. As a result, the measured reflectance of the Pd(N)/Y(N) multilayer achieves 30% at λ = 9.3 nm. The peak reflectivity value is limited by the remaining interlayers and the formation of the YN compound inside the yttrium layers, resulting in an increased absorption.

  19. Measurement of central corneal thickness with optical low-coherence reflectometry and ultrasound pachymetry in normal and post-femtosecond laser in situ keratomileusis eyes.

    PubMed

    Huang, Jinhai; Liao, Na; Savini, Giacomo; Li, Yuanguang; Bao, Fangjun; Yu, Ye; Yu, Ayong; Wang, Qinmei

    2015-02-01

    To determine the repeatability and reproducibility of measurements of central corneal thickness (CCT) using optical low-coherence reflectometry (Lenstar LS900; Haag Streit) in normal eyes and post-femtosecond laser in situ keratomileusis (post-FS-LASIK) eyes and evaluate their agreement with ultrasound (US) pachymetry. CCT was measured using Lenstar and US pachymetry sequentially in normal and post-FS-LASIK eyes by 2 experienced observers. Intraoperator repeatability and interoperator reproducibility were assessed by within-subject standard deviation, test-retest repeatability, coefficient of variation (CoV), and intraclass correlation coefficient. Paired t-tests and Bland-Altman plots were used for analyzing agreement between the 2 devices. In this study, 55 healthy subjects and 50 post-FS-LASIK patients were recruited. Test-retest repeatability of Lenstar was within 10 μm, CoV was less than 1.0%, and intraclass correlation coefficient was more than 0.9 in both normal and post-FS-LASIK groups. Mean difference between these methods was 1.4 ± 4.2 μm and -1.7 ± 5.4 μm, respectively. Moreover, measurements of CCT showed narrow 95% limits of agreement (range, normal group: -6.8 and 9.6 μm; post-FS-LASIK group: -12.4 and 8.9 μm), which implied good agreement. Measurements of CCT using Lenstar showed excellent intraoperator repeatability and interoperator reproducibility both in normal eyes and post-FS-LASIK eyes. Measurements of CCT using Lenstar and US pachymetry showed good agreement and both can be used interchangeably.

  20. Note: 4-bounce neutron polarizer for reflectometry applications

    NASA Astrophysics Data System (ADS)

    Nagy, B.; Merkel, D. G.; Jakab, L.; Füzi, J.; Veres, T.; Bottyán, L.

    2018-05-01

    A neutron polarizer using four successive reflections on m = 2.5 supermirrors was built and installed at the GINA neutron reflectometer at the Budapest Neutron Centre. This simple setup exhibits 99.6% polarizing efficiency with 80% transmitted intensity of the selected polarization state. Due to the geometry, the higher harmonics in the incident beam are filtered out, while the optical axis of the beam remains intact for easy mounting and dismounting the device in an existing experimental setup.

  1. Terahertz reflectometry imaging for low and high grade gliomas

    NASA Astrophysics Data System (ADS)

    Ji, Young Bin; Oh, Seung Jae; Kang, Seok-Gu; Heo, Jung; Kim, Sang-Hoon; Choi, Yuna; Song, Seungri; Son, Hye Young; Kim, Se Hoon; Lee, Ji Hyun; Haam, Seung Joo; Huh, Yong Min; Chang, Jong Hee; Joo, Chulmin; Suh, Jin-Suck

    2016-10-01

    Gross total resection (GTR) of glioma is critical for improving the survival rate of glioma patients. One of the greatest challenges for achieving GTR is the difficulty in discriminating low grade tumor or peritumor regions that have an intact blood brain barrier (BBB) from normal brain tissues and delineating glioma margins during surgery. Here we present a highly sensitive, label-free terahertz reflectometry imaging (TRI) that overcomes current key limitations for intraoperative detection of World Health Organization (WHO) grade II (low grade), and grade III and IV (high grade) gliomas. We demonstrate that TRI provides tumor discrimination and delineation of tumor margins in brain tissues with high sensitivity on the basis of Hematoxylin and eosin (H&E) stained image. TRI may help neurosurgeons to remove gliomas completely by providing visualization of tumor margins in WHO grade II, III, and IV gliomas without contrast agents, and hence, improve patient outcomes.

  2. GOLD's coating and testing facilities for ISSIS-WSO

    NASA Astrophysics Data System (ADS)

    Larruquert, Juan I.; Méndez, José Antonio; Aznárez, José Antonio; Vidal-Dasilva, Manuela; García-Cortés, Sergio; Rodríguez-de Marcos, Luis; Fernández-Perea, Mónica

    2011-09-01

    ISSIS imager has been thought as an open purpose instrument within the World Space Observatory (WSO) international space mission. The highest priorities of ISSIS, an instrument to be developed by Spain, are to guarantee high spatial resolution and high sensitivity down to the far ultraviolet (FUV). The paper displays the capacities of GOLD for multilayer deposition and FUV reflectometry, among other metrologies, for ISSIS optical elements. Deposition of coatings for ISSIS-WSO will be carried out in a new UHV system with a 75-cm diameter deposition chamber. The purpose of the new laboratory is the deposition of coatings satisfying the constraints for FUV space optics. The first target coating to be developed in this new laboratory is Al protected with MgF2, with optimum reflectance down to ˜120 nm. GOLD's existing reflectometer is able to characterize flat pieces both by transmittance and reflectance, and the latter from near-normal to grazing incidence, in the range from 12 to 200 nm. Other metrologies that will be available at GOLD for ISSIS's coatings and filters include optical thickness of filters to assure parfocality, filter wedge, and coating and filter scattering.

  3. Novel Optical Methods for Identification, Imaging, and Preservation of the Cavernous Nerves Responsible for Penile Erections during Prostate Cancer Surgery

    DTIC Science & Technology

    2010-03-01

    of near- IR l ight as a f unction of source-detector distance. The effective attenuation coefficient (μeff) and optical penetration depth (OPD...were then calculated for near- IR wavelengths of 1064, 1307, and 1555 nm (Table 1). A total of ten canine samples were used for this study. At...Diego, CA, 2009). Chitchian S, Fried NM. Near- IR optical properties of canine prostate tissue using oblique incidence reflectometry. Proc. SPIE

  4. Radio-frequency reflectometry on an undoped AlGaAs/GaAs single electron transistor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    MacLeod, S. J.; See, A. M.; Keane, Z. K.

    2014-01-06

    Radio frequency reflectometry is demonstrated in a sub-micron undoped AlGaAs/GaAs device. Undoped single electron transistors (SETs) are attractive candidates to study single electron phenomena, due to their charge stability and robust electronic properties after thermal cycling. However, these devices require a large top-gate, which is unsuitable for the fast and sensitive radio frequency reflectometry technique. Here, we demonstrate that rf reflectometry is possible in an undoped SET.

  5. Frozen O 2 layer revealed by neutron reflectometry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Steffen, A.; Glavic, A.; Holderer, O.

    2016-05-27

    We investigated a 63 thick film originating from frozen air on a solid substrate via neutron reflectometry. Furthermore, the experiment shows that neutron reflectometry allows performing chemical surface analysis by quantifying the composition of this frozen layer and identifies the film to be frozen oxygen.

  6. Time-of-Flight Polarized Neutron Reflectometry on PLATYPUS: Status and Future Developments

    NASA Astrophysics Data System (ADS)

    Saerbeck, T.; Cortie, D. L.; Brück, S.; Bertinshaw, J.; Holt, S. A.; Nelson, A.; James, M.; Lee, W. T.; Klose, F.

    Time-of-flight (ToF) polarized neutron reflectometry enables the detailed investigation of depth-resolved magnetic structures in thin film and multilayer magnetic systems. The general advantage of the time-of-flight mode of operation over monochromatic instruments is a decoupling of spectral shape and polarization of the neutron beam with variable resolution. Thus, a wide Q-range can be investigated using a single angle of incidence, with resolution and flux well-adjusted to the experimental requirement. Our paper reviews the current status of the polarization equipment of the ToF reflectometer PLATYPUS and presents first results obtained on stratified Ni80Fe20/α-Fe2O3 films, revealing the distribution of magnetic moments in an exchange bias system. An outlook on the future development of the PLATYPUS polarization system towards the implementation of a polarized 3He cell is presented and discussed with respect to the efficiency and high Q-coverage up to 1 Å-1 and 0.15 Å-1 in the vertical and lateral momentum transfer, respectively.

  7. Advancing Reflectrometry

    DTIC Science & Technology

    2013-05-21

    13. SUPPLEMENTARY NOTES 14. ABSTRACT Reflectometry , a microwave remote sensing technique to extract geophysical data from scattered satellite...transmissions, was first demonstrated using Global Navigation Satellite System (GNSS) reflections. Recently, reflectometry has been extended to digital...potential missions. a 15. SUBJECT TERMS Reflectometry , Ocean Winds, Global Navigation Satellites, Communication Satellites 16. SECURITY

  8. Development of graphene process control by industrial optical spectroscopy setup

    NASA Astrophysics Data System (ADS)

    Fursenko, O.; Lukosius, M.; Lupina, G.; Bauer, J.; Villringer, C.; Mai, A.

    2017-06-01

    The successful integration of graphene into microelectronic devices depends strongly on the availability of fast and nondestructive characterization methods of graphene grown by CVD on large diameter production wafers [1-3] which are in the interest of the semiconductor industry. Here, a high-throughput optical metrology method for measuring the thickness and uniformity of large-area graphene sheets is demonstrated. The method is based on the combination of spectroscopic ellipsometry and normal incidence reflectometry in UV-Vis wavelength range (200-800 nm) with small light spots ( 30 μm2) realized in wafer optical metrology tool. In the first step graphene layers were transferred on a SiO2/Si substrate in order to determine the optical constants of graphene by the combination of multi-angle ellipsometry and reflectometry. Then these data were used for the development of a process control recipe of CVD graphene on 200 mm Ge(100)/Si(100) wafers. The graphene layer quality was additionally monitored by Raman spectroscopy. Atomic force microscopy measurements were performed for micro topography evaluation. In consequence, a robust recipe for unambiguous thickness monitoring of all components of a multilayer film stack, including graphene, surface residuals or interface layer underneath graphene and surface roughness is developed. Optical monitoring of graphene thickness uniformity over a wafer has shown an excellent long term stability (s=0.004 nm) regardless of the growth of interfacial GeO2 and surface roughness. The sensitivity of the optical identification of graphene during microelectronic processing was evaluated. This optical metrology technique with combined data collection exhibit a fast and highly precise method allowing one an unambiguous detection of graphene after transferring as well as after the CVD deposition process on a Ge(100)/Si(100) wafer. This approach is well suited for industrial applications due to its repeatability and flexibility.

  9. Optical coherence tomography guided dental drill

    DOEpatents

    DaSilva, Luiz B.; Colston, Jr., Bill W.; James, Dale L.

    2002-01-01

    A dental drill that has one or multiple single mode fibers that can be used to image in the vicinity of the drill tip. It is valuable to image below the surface being drilled to minimize damage to vital or normal tissue. Identifying the boundary between decayed and normal enamel (or dentine) would reduce the removal of viable tissue, and identifying the nerve before getting too close with the drill could prevent nerve damage. By surrounding a drill with several optical fibers that can be used by an optical coherence domain reflectometry (OCDR) to image several millimeters ahead of the ablation surface will lead to a new and improved dental treatment device.

  10. Time Domain Reflectometry for Damage Detection of Laminated CFRP plate

    DTIC Science & Technology

    2011-08-18

    Final Report PROJECT ID: AOARD-10-4112 Title: Time Domain Reflectometry for damage detection of laminated CFRP plate Researcher: Professor Akira...From July/2010 To July/2011 Abstract Recently, high toughness Carbon Fiber Reinforced Polymer (CFRP) laminates are used to primary structures. The...large laminated CFRP structures. In the previous study, Time Domain Reflectometry (TDR) method is adopted for the detection of the fiber breakages of

  11. Distributed fiber strain and vibration sensor based on Brillouin optical time-domain reflectometry and polarization optical time-domain reflectometry.

    PubMed

    Wang, Feng; Zhang, Xuping; Wang, Xiangchuan; Chen, Haisheng

    2013-07-15

    A distributed fiber strain and vibration sensor which effectively combines Brillouin optical time-domain reflectometry and polarization optical time-domain reflectometry is proposed. Two reference beams with orthogonal polarization states are, respectively, used to perform the measurement. By using the signal obtained from either reference beam, the vibration of fiber can be measured from the polarization effect. After combining the signals obtained by both reference beams, the strain can be measured from the Brillouin effect. In the experiment, 10 m spatial resolution, 0.6 kHz frequency measurement range, 2.5 Hz frequency resolution, and 0.2 MHz uncertainty of Brillouin frequency measurement are realized for a 4 km sensing distance.

  12. Comparison of immersion ultrasound, partial coherence interferometry, and low coherence reflectometry for ocular biometry in cataract patients.

    PubMed

    Montés-Micó, Robert; Carones, Francesco; Buttacchio, Antonietta; Ferrer-Blasco, Teresa; Madrid-Costa, David

    2011-09-01

    To compare ocular biometry parameters measured with immersion ultrasound, partial coherence interferometry, and low coherence reflectometry in cataract patients. Measurements of axial length and anterior chamber depth were analyzed and compared using immersion ultrasound, partial coherence interferometry, and low coherence reflectometry. Keratometry (K), flattest axis, and white-to-white measurements were compared between partial coherence interferometry and low coherence reflectometry. Seventy-eight cataract (LOCS II range: 1 to 3) eyes of 45 patients aged between 42 and 90 years were evaluated. A subanalysis as a function of cataract degree was done for axial length and anterior chamber depth between techniques. No statistically significant differences were noted for the study cohort or within each cataract degree among the three techniques for axial length and anterior chamber depth (P>.05, ANOVA test). Measurements between techniques were highly correlated for axial length (R=0.99) and anterior chamber depth (R=0.90 to 0.96) for all methods. Keratometry, flattest axis, and white-to-white measurements were comparable (paired t test, P>.1) and correlated well between partial coherence interferometry and low coherence reflectometry (K1 [R=0.95), K2 [R=0.97], flattest axis [R=0.95], and white-to-white [R=0.92]). Immersion ultrasound, partial coherence interferometry, and low coherence reflectometry provided comparable ocular biometry measurements in cataractous eyes. Copyright 2011, SLACK Incorporated.

  13. Evidence of Formation of Superdense Nonmagnetic Cobalt.

    PubMed

    Banu, Nasrin; Singh, Surendra; Satpati, B; Roy, A; Basu, S; Chakraborty, P; Movva, Hema C P; Lauter, V; Dev, B N

    2017-02-03

    Because of the presence of 3d transition metals in the Earth's core, magnetism of these materials in their dense phases has been a topic of great interest. Theory predicts a dense face-centred-cubic phase of cobalt, which would be nonmagnetic. However, this dense nonmagnetic cobalt has not yet been observed. Recent investigations in thin film polycrystalline materials have shown the formation of compressive stress, which can increase the density of materials. We have discovered the existence of ultrathin superdense nonmagnetic cobalt layers in a polycrystalline cobalt thin film. The densities of these layers are about 1.2-1.4 times the normal density of Co. This has been revealed by X-ray reflectometry experiments, and corroborated by polarized neutron reflectometry (PNR) experiments. Transmission electron microscopy provides further evidence. The magnetic depth profile, obtained by PNR, shows that the superdense Co layers near the top of the film and at the film-substrate interface are nonmagnetic. The major part of the Co film has the usual density and magnetic moment. These results indicate the possibility of existence of nonmagnetic Co in the earth's core under high pressure.

  14. Differential reflectometry versus tactile sense detection of subgingival calculus in dentistry

    NASA Astrophysics Data System (ADS)

    Shakibaie, Fardad; Walsh, Laurence J.

    2012-10-01

    Detecting dental calculus is clinically challenging in dentistry. This study used typodonts with extracted premolar and molar teeth and simulated gingival tissue to compare the performance of differential reflectometry and periodontal probing. A total of 30 extracted teeth were set in an anatomical configuration in stone to create three typodonts. Clear polyvinyl siloxane impression material was placed to replicate the periodontal soft tissues. Pocket depths ranged from 10 to 15 mm. The three models were placed in a phantom head, and an experienced dentist assessed the presence of subgingival calculus first using the DetecTar (differential reflectometry) and then a periodontal probe. Scores from these two different methods were compared to the gold standard (direct examination of the root surface using 20× magnification) to determine the accuracy and reproducibility. Differential reflectometry was more accurate than tactile assessment (79% versus 60%), and its reproducibility was also higher (Cohen kappa 0.54 versus 0.39). Both methods performed better on single rooted premolar teeth than on multirooted teeth. These laboratory results indicate that differential reflectometry allows more accurate and reproducible detection of subgingival calculus than conventional probing, and supports its use for supplementing traditional periodontal examination methods in dental practice.

  15. X-ray mirror development and testing for the ATHENA mission

    NASA Astrophysics Data System (ADS)

    Della Monica Ferreira, Desiree; Jakobsen, Anders C.; Massahi, Sonny; Christensen, Finn E.; Shortt, Brian; Garnæs, Jørgen; Torras-Rosell, Antoni; Krumrey, Michael; Cibik, Levent; Marggraf, Stefanie

    2016-07-01

    This study reports development and testing of coatings on silicon pore optics (SPO) substrates including pre and post coating characterisation of the x-ray mirrors using Atomic Force Microscopy (AFM) and X-ray reflectometry (XRR) performed at the 8 keV X-ray facility at DTU Space and with synchrotron radiation in the laboratory of PTB at BESSY II. We report our findings on surface roughness and coating reflectivity of Ir/B4C coatings considering the grazing incidence angles and energies of ATHENA and long term stability of Ir/B4C, Pt/B4C, W/Si and W/B4C coatings.

  16. Distributed measurement of polarization mode coupling in fiber ring based on P-OTDR complete polarization state detection.

    PubMed

    Huang, Zejia; Wu, Chongqing; Wang, Zhi; Wang, Jian; Liu, Lanlan

    2018-02-19

    Using a quaternion method, the polarization mode-coupling coefficient can be derived from three components of the Stokes vectors at three adjacent points along a fiber. A complete polarization optical time-domain reflectometry scheme for polarization mode coupling distributed measurement in polarization-maintaining fiber ring is proposed based on the above theoretical derivations. By comparing the measurement results of two opposite incident directions and two orthogonal polarization axes of polarization-maintaining fiber rings with different lengths, the feasibility and repeatability of the measurement scheme are verified experimentally with a positioning spatial resolution of 1 meter.

  17. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wu Shioumin; Kruijs, Robbert van de; Zoethout, Erwin

    Ion sputtering yields for Ru, Mo, and Si under Ar{sup +} ion bombardment in the near-threshold energy range have been studied using an in situ weight-loss method with a Kaufman ion source, Faraday cup, and quartz crystal microbalance. The results are compared to theoretical models. The accuracy of the in situ weight-loss method was verified by thickness-decrease measurements using grazing incidence x-ray reflectometry, and results from both methods are in good agreement. These results provide accurate data sets for theoretical modeling in the near-threshold sputter regime and are of relevance for (optical) surfaces exposed to plasmas, as, for instance, inmore » extreme ultraviolet photolithography.« less

  18. Determining soil volumetric moisture content using time domain reflectometry

    DOT National Transportation Integrated Search

    1998-02-01

    Time domain reflectometry (TDR) is a technique used to measure indirectly the in situ volumetric moisture content of soil. Current research provides a variety of prediction equations that estimate the volumetric moisture content using the dielectric ...

  19. Inclinometer--time-domain reflectometry comparative study : research implementation plan.

    DOT National Transportation Integrated Search

    2005-10-01

    ODOT currently uses slope indicator probing to analyze subsurface conditions at roadway landslide : locations. However, the current method is subject to several limitations, and time domain reflectometry : (TDR) has been proposed as an alternative to...

  20. 90° magnetic coupling in a NiFe/FeMn/biased NiFe multilayer spin valve component investigated by polarized neutron reflectometry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Callori, S. J., E-mail: sara.callori@ansto.gov.au; Bertinshaw, J.; Bragg Institute, Australian Nuclear Science and Technology Organization, Lucas Heights, New South Wales 2234

    2014-07-21

    We have observed 90° magnetic coupling in a NiFe/FeMn/biased NiFe multilayer system using polarized neutron reflectometry. Magnetometry results show magnetic switching for both the biased and free NiFe layers, the latter of which reverses at low applied fields. As these measurements are only capable of providing information about the total magnetization within a sample, polarized neutron reflectometry was used to investigate the reversal behavior of the NiFe layers individually. Both the non-spin-flip and spin-flip neutron reflectometry signals were tracked around the free NiFe layer hysteresis loop and were used to detail the evolution of the magnetization during reversal. At lowmore » magnetic fields near the free NiFe coercive field, a large spin-flip signal was observed, indicating magnetization aligned perpendicular to both the applied field and pinned layer.« less

  1. HEKATE-A novel grazing incidence neutron scattering concept for the European Spallation Source.

    PubMed

    Glavic, Artur; Stahn, Jochen

    2018-03-01

    Structure and magnetism at surfaces and buried interfaces on the nanoscale can only be accessed by few techniques, one of which is grazing incidence neutron scattering. While the technique has its strongest limitation in a low signal and large background, due to the low scattering probability and need for high resolution, it can be expected that the high intensity of the European Spallation Source in Lund, Sweden, will make many more such studies possible, warranting a dedicated beamline for this technique. We present an instrument concept, Highly Extended K range And Tunable Experiment (HEKATE), for surface scattering that combines the advantages of two Selene neutron guides with unique capabilities of spatially separated distinct wavelength frames. With this combination, it is not only possible to measure large specular reflectometry ranges, even on free liquid surfaces, but also to use two independent incident beams with tunable sizes and resolutions that can be optimized for the specifics of the investigated samples. Further the instrument guide geometry is tuned for reduction of high energy particle background and only uses low to moderate supermirror coatings for high reliability and affordable cost.

  2. HEKATE—A novel grazing incidence neutron scattering concept for the European Spallation Source

    NASA Astrophysics Data System (ADS)

    Glavic, Artur; Stahn, Jochen

    2018-03-01

    Structure and magnetism at surfaces and buried interfaces on the nanoscale can only be accessed by few techniques, one of which is grazing incidence neutron scattering. While the technique has its strongest limitation in a low signal and large background, due to the low scattering probability and need for high resolution, it can be expected that the high intensity of the European Spallation Source in Lund, Sweden, will make many more such studies possible, warranting a dedicated beamline for this technique. We present an instrument concept, Highly Extended K range And Tunable Experiment (HEKATE), for surface scattering that combines the advantages of two Selene neutron guides with unique capabilities of spatially separated distinct wavelength frames. With this combination, it is not only possible to measure large specular reflectometry ranges, even on free liquid surfaces, but also to use two independent incident beams with tunable sizes and resolutions that can be optimized for the specifics of the investigated samples. Further the instrument guide geometry is tuned for reduction of high energy particle background and only uses low to moderate supermirror coatings for high reliability and affordable cost.

  3. Time-domain reflectometry of water content in portland cement concrete

    DOT National Transportation Integrated Search

    1997-11-01

    Time-domain reflectometry is useful for measuring the moisture content of solids. However, little information exists on its use with portland cement concrete. By monitoring the response from TDR sensors embedded in concrete as the concrete dried, the...

  4. Polarization sensitive optical low-coherence reflectometry for blood glucose monitoring in human subjects

    NASA Astrophysics Data System (ADS)

    Solanki, Jitendra; Choudhary, Om Prakash; Sen, P.; Andrews, J. T.

    2013-07-01

    A device based on polarization sensitive optical low-coherence reflectometry is developed to monitor blood glucose levels in human subjects. The device was initially tested with tissue phantom. The measurements with human subjects for various glucose concentration levels are found to be linearly dependent on the ellipticity obtainable from the home-made phase-sensitive optical low-coherence reflectometry device. The linearity obtained between glucose concentration and ellipticity are explained with theoretical calculations using Mie theory. A comparison of results with standard clinical methods establishes the utility of the present device for non-invasive glucose monitoring.

  5. Inclinometer - Time Domain Reflectometry Comparative Study

    DOT National Transportation Integrated Search

    2004-12-01

    Four pairs of inclinometers and time domain reflectometry (TDR) cables were set up to make a side-by-side : comparison of the performance of these systems in detecting slippage of soils in the shoulders of State Route 124 : and State Route 338 in Mei...

  6. Inclinometer--time-domain reflectometry comparative study.

    DOT National Transportation Integrated Search

    2004-12-01

    Four pairs of inclinometers and time domain reflectometry (TDR) cables were set up to make a side-by-side : comparison of the performance of these systems in detecting slippage of soils in the shoulders of State Route 124 : and State Route 338 in Mei...

  7. A numerically-stable algorithm for calibrating single six-ports for national microwave reflectometry

    NASA Astrophysics Data System (ADS)

    Hodgetts, T. E.

    1990-11-01

    A full description and analysis of the numerically stable algorithm currently used for calibrating single six ports or multi states for national microwave reflectometry, employing as standards four one port devices having known voltage reflection coefficients, is given.

  8. Dynamic Detection of Spinal Cord Position During Postural Changes Using Near-Infrared Reflectometry.

    PubMed

    Wolf, Erich W

    2015-08-01

    Motion of the spinal cord relative to a spinal cord stimulator epidural electrode array can cause suboptimal stimulation: either noxious, inefficient, or insufficient. Adaptive stimulation attempts to mitigate these effects by modulating stimulation parameters in a position-dependent fashion. Near-infrared (NIR) reflectometry is demonstrated to provide real-time direct measurement of spinal cord position at the site of stimulation, which can facilitate closed-loop adaptive stimulation during static and dynamic motion states. A miniature sensor array consisting of an NIR light emitting diode flanked by phototransistors potted in epoxy was placed in the dorsal epidural space of a human cadaver at the T8 level via laminotomy. Turgor of the subarachnoid space was maintained by intrathecal infusion of saline. NIR reflectance was measured as the cadaver was rotated about its longitudinal axis on a gantry. NIR reflectance was correlated with gantry position and velocity. NIR reflectometry suggests gravitational force is the primary determinant of cord position in static, ordinal positions. Under dynamic motion conditions, there was statistically significant cross-correlation between reflectometry data and the tangential velocity squared, suggesting that centripetal force was the primary determinant of cord position as the gantry was rotated. Reflectometry data strongly correlated with a simple geometric model of anticipated spinal cord precession within the spinal canal. Spinal cord position during dynamic motion has been shown to differ from static predictions due to additional influences such as centripetal force. These findings underscore limitations in extrapolating spinal cord position from surrogates such as body position or body acceleration at sites remote from the stimulating electrodes. NIR reflectometry offers a real-time direct measure of spinal cord position in both static and dynamic motion states, which may facilitate closed-loop adaptive stimulation applications. © 2015 International Neuromodulation Society.

  9. Time domain reflectometry waveform analysis with second order bounded mean oscillation

    USDA-ARS?s Scientific Manuscript database

    Tangent-line methods and adaptive waveform interpretation with Gaussian filtering (AWIGF) have been proposed for determining reflection positions of time domain reflectometry (TDR) waveforms. However, the accuracy of those methods is limited for short probe TDR sensors. Second order bounded mean osc...

  10. Thermal stability of photovoltaic a-Si:H determined by neutron reflectometry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Qviller, A. J., E-mail: atlejq@ife.no; Haug, H.; You, C. C.

    2014-12-08

    Neutron and X-ray reflectometry were used to determine the layer structure and hydrogen content of thin films of amorphous silicon (a-Si:H) deposited onto crystalline silicon (Si) wafers for surface passivation in solar cells. The combination of these two reflectometry techniques is well suited for non-destructive probing of the structure of a-Si:H due to being able to probe buried interfaces and having sub-nanometer resolution. Neutron reflectometry is also unique in its ability to allow determination of density gradients of light elements such as hydrogen (H). The neutron scattering contrast between Si and H is strong, making it possible to determine themore » H concentration in the deposited a-Si:H. In order to correlate the surface passivation properties supplied by the a-Si:H thin films, as quantified by obtainable effective minority carrier lifetime, photoconductance measurements were also performed. It is shown that the minority carrier lifetime falls sharply when H has been desorbed from a-Si:H by annealing.« less

  11. First density profile measurements using frequency modulation of the continuous wave reflectometry on JETa)

    NASA Astrophysics Data System (ADS)

    Meneses, L.; Cupido, L.; Sirinelli, A.; Manso, M. E.; Jet-Efds Contributors

    2008-10-01

    We present the main design options and implementation of an X-mode reflectometer developed and successfully installed at JET using an innovative approach. It aims to prove the viability of measuring density profiles with high spatial and temporal resolution using broadband reflectometry operating in long and complex transmission lines. It probes the plasma with magnetic fields between 2.4 and 3.0 T using the V band [~(0-1.4)×1019 m-3]. The first experimental results show the high sensitivity of the diagnostic when measuring changes in the plasma density profile occurring ITER relevant regimes, such as ELMy H-modes. The successful demonstration of this concept motivated the upgrade of the JET frequency modulation of the continuous wave (FMCW) reflectometry diagnostic, to probe both the edge and core. This new system is essential to prove the viability of using the FMCW reflectometry technique to probe the plasma in next step devices, such as ITER, since they share the same waveguide complexity.

  12. Low Density ITB Studies Using the Upgraded C-Mod Reflectometry System

    NASA Astrophysics Data System (ADS)

    Dominguez, A.; Edlund, E.; Fiore, C. L.; Lin, L.; Marmar, E. S.; Snipes, J. A.; Porkolab, M.; Kramer, G. J.; Rowan, W. L.

    2007-11-01

    The Alcator C-Mod reflectometry system was recently upgraded in two ways: The low frequency channels were changed from amplitude modulation - in which two microwave signals, slightly separated in frequency, are injected into the plasma - to baseband, where a single frequency is used, in order to improve density fluctuation measurements. The second change, a variable frequency channel operating over the range from 122GHz to 140GHz (with corresponding density cutoffs of 1.84-2.43x10^20m-3) has been installed in collaboration with PPPL. Initial results from the upgraded system are presented, including the study of low density Internal Transport Barriers. Using O-mode waves, the reflectometry system is able to radially localize density fluctuations on the low field side along the tokamak midplane. It can, therefore, be used to probe the foot of low density ITBs. The corresponding reflectometry data will be compared to those of other fluctuation diagnostics, including Phase Contrast Imaging and magnetic pick-up coils.

  13. Directly coupled vs conventional time domain reflectometry in soils

    USDA-ARS?s Scientific Manuscript database

    Time domain reflectometry (TDR), a technique for estimation of soil water, measures the travel time of an electromagnetic pulse on electrodes embedded in the soil, but has limited application in commercial agriculture due to costs, labor, and sensing depth. Conventional TDR systems have employed ana...

  14. Improved theory of time domain reflectometry with variable coaxial cable length for electrical conductivity measurements

    USDA-ARS?s Scientific Manuscript database

    Although empirical models have been developed previously, a mechanistic model is needed for estimating electrical conductivity (EC) using time domain reflectometry (TDR) with variable lengths of coaxial cable. The goals of this study are to: (1) derive a mechanistic model based on multisection tra...

  15. Measurement of electron temperature and density of the edge plasma of JET by ECE and microwave reflectometry

    NASA Astrophysics Data System (ADS)

    Bartlett, D. V.; Costley, A. E.; Porte, L.; Prentice, R.; Salmon, N. A.; Sips, G.

    1990-12-01

    The potential of electron cyclotron emission and microwave reflectometry as techniques for measuring the electron temperature and density in the edge region of tokamak plasmas is investigated. Experiments to realize this potential on JET are described and some illustrative results presented.

  16. Faster diffraction-based overlay measurements with smaller targets using 3D gratings

    NASA Astrophysics Data System (ADS)

    Li, Jie; Kritsun, Oleg; Liu, Yongdong; Dasari, Prasad; Volkman, Catherine; Hu, Jiangtao

    2012-03-01

    Diffraction-based overlay (DBO) technologies have been developed to address the overlay metrology challenges for 22nm technology node and beyond. Most DBO technologies require specially designed targets that consist of multiple measurement pads, which consume too much space and increase measurement time. The traditional empirical approach (eDBO) using normal incidence spectroscopic reflectometry (NISR) relies on linear response of the reflectance with respect to overlay displacement within a small range. It offers convenience of quick recipe setup since there is no need to establish a model. However it requires three or four pads per direction (x or y) which adds burden to throughput and target size. Recent advances in modeling capability and computation power enabled mDBO, which allows overlay measurement with reduced number of pads, thus reducing measurement time and DBO target space. In this paper we evaluate the performance of single pad mDBO measurements using two 3D targets that have different grating shapes: squares in boxes and L-shapes in boxes. Good overlay sensitivities are observed for both targets. The correlation to programmed shifts and image-based overlay (IBO) is excellent. Despite the difference in shapes, the mDBO results are comparable for square and L-shape targets. The impact of process variations on overlay measurements is studied using a focus and exposure matrix (FEM) wafer. Although the FEM wafer has larger process variations, the correlation of mDBO results with IBO measurements is as good as the normal process wafer. We demonstrate the feasibility of single pad DBO measurements with faster throughput and smaller target size, which is particularly important in high volume manufacturing environment.

  17. Nondestructive Testing Information Analysis Center, 1979.

    DTIC Science & Technology

    1980-09-01

    transmission and reflectometry Ultrasonic imaging Spectrum analysis Acoustic emission * LIQUID PENETRANT TESTING Dye penetrants Fluorescent penetrants...OPTICAL TESTING Visual testing Optical reflectometry and transmission Holography * THERMAL TESTING Infrared radiometry The rmography 13 The present...on our surveillance effectiveness, we also scan Current Contents, NASA /SCAN, and the monthly Engineering Index and Science Abstracts. New books

  18. NASA Hybrid Reflectometer Project

    NASA Technical Reports Server (NTRS)

    Lynch, Dana; Mancini, Ron (Technical Monitor)

    2002-01-01

    Time-domain and frequency-domain reflectometry have been used for about forty years to locate opens and shorts in cables. Interpretation of reflectometry data is as much art as science. Is there information in the data that is being missed? Can the reflectometers be improved to allow us to detect and locate defects in cables that are not outright shorts or opens? The Hybrid Reflectometer Project was begun this year at NASA Ames Research Center, initially to model wire physics, simulating time-domain reflectometry (TDR) signals in those models and validating the models against actual TDR data taken on testbed cables. Theoretical models of reflectometry in wires will give us an understanding of the merits and limits of these techniques and will guide the application of a proposed hybrid reflectometer with the aim of enhancing reflectometer sensitivity to the point that wire defects can be detected. We will point out efforts by some other researchers to apply wire physics models to the problem of defect detection in wires and we will describe our own initial efforts to create wire physics models and report on testbed validation of the TDR simulations.

  19. Novel analysis technique for measuring edge density fluctuation profiles with reflectometry in the Large Helical Device.

    PubMed

    Creely, A J; Ida, K; Yoshinuma, M; Tokuzawa, T; Tsujimura, T; Akiyama, T; Sakamoto, R; Emoto, M; Tanaka, K; Michael, C A

    2017-07-01

    A new method for measuring density fluctuation profiles near the edge of plasmas in the Large Helical Device (LHD) has been developed utilizing reflectometry combined with pellet-induced fast density scans. Reflectometer cutoff location was calculated by proportionally scaling the cutoff location calculated with fast far infrared laser interferometer (FIR) density profiles to match the slower time resolution results of the ray-tracing code LHD-GAUSS. Plasma velocity profile peaks generated with this reflectometer mapping were checked against velocity measurements made with charge exchange spectroscopy (CXS) and were found to agree within experimental uncertainty once diagnostic differences were accounted for. Measured density fluctuation profiles were found to peak strongly near the edge of the plasma, as is the case in most tokamaks. These measurements can be used in the future to inform inversion methods of phase contrast imaging (PCI) measurements. This result was confirmed with both a fixed frequency reflectometer and calibrated data from a multi-frequency comb reflectometer, and this method was applied successfully to a series of discharges. The full width at half maximum of the turbulence layer near the edge of the plasma was found to be only 1.5-3 cm on a series of LHD discharges, less than 5% of the normalized minor radius.

  20. Novel analysis technique for measuring edge density fluctuation profiles with reflectometry in the Large Helical Device

    NASA Astrophysics Data System (ADS)

    Creely, A. J.; Ida, K.; Yoshinuma, M.; Tokuzawa, T.; Tsujimura, T.; Akiyama, T.; Sakamoto, R.; Emoto, M.; Tanaka, K.; Michael, C. A.

    2017-07-01

    A new method for measuring density fluctuation profiles near the edge of plasmas in the Large Helical Device (LHD) has been developed utilizing reflectometry combined with pellet-induced fast density scans. Reflectometer cutoff location was calculated by proportionally scaling the cutoff location calculated with fast far infrared laser interferometer (FIR) density profiles to match the slower time resolution results of the ray-tracing code LHD-GAUSS. Plasma velocity profile peaks generated with this reflectometer mapping were checked against velocity measurements made with charge exchange spectroscopy (CXS) and were found to agree within experimental uncertainty once diagnostic differences were accounted for. Measured density fluctuation profiles were found to peak strongly near the edge of the plasma, as is the case in most tokamaks. These measurements can be used in the future to inform inversion methods of phase contrast imaging (PCI) measurements. This result was confirmed with both a fixed frequency reflectometer and calibrated data from a multi-frequency comb reflectometer, and this method was applied successfully to a series of discharges. The full width at half maximum of the turbulence layer near the edge of the plasma was found to be only 1.5-3 cm on a series of LHD discharges, less than 5% of the normalized minor radius.

  1. Preparation for B4C/Mo2C multilayer deposition of alternate multilayer gratings with high efficiency in the 0.5-2.5 keV energy range

    NASA Astrophysics Data System (ADS)

    Choueikani, Fadi; Delmotte, Franck; Bridou, Françoise; Lagarde, Bruno; Mercere, Pascal; Otero, Edwige; Ohresser, Philippe; Polack, François

    2013-03-01

    This paper presents a study of B4C/Mo2C multilayers mirrors with the aim of using it in the achievement of Alternate MultiLayer (AML) grating. Such component allows a high efficiency in the 500-2500 eV energy range for the DEIMOS beamline. Multilayers were deposited on silicon substrate. They are characterized by reflectometry under grazing incidence. Numerical adjustments were performed with a model of two layers in the period without any interfacial. A prototype of AML grating was fabricated and characterized. The efficiency of the first order of diffraction was worth 15% at 1700 eV.

  2. Nondestructive Testing Information Analysis Center, 1982.

    DTIC Science & Technology

    1983-03-01

    RF Fields Microwaves Magnetic Flux Analysis Magnetic Particles * ULTRASONIC AND ACOUSTIC TESTING Ultrasonic Transmission and Reflectometry Ultrasonic... Reflectometry and Transmission Holography THERMAL TESTING Infrared Radiometry Thermography 3 The present organization and personnel of NTIAC are...the current core and secondary serials. As an added check on our surveillance effectiveness, we also scan Current Contents, NASA /SCAN, as well as the

  3. Water content measurement in forest soils and decayed wood using time domain reflectometry

    Treesearch

    Andrew Gray; Thomas Spies

    1995-01-01

    The use of time domain reflectometry to measure moisture content in forest soils and woody debris was evaluated. Calibrations were developed on undisturbed soil cores from four forest stands and on point samples from decayed logs. An algorithm for interpreting irregularly shaped traces generated by the reflectometer was also developed. Two different calibration...

  4. Studies of electrochemical interfaces by TOF neutron reflectometry at the IBR-2 reactor

    NASA Astrophysics Data System (ADS)

    Petrenko, V. I.; Gapon, I. V.; Rulev, A. A.; Ushakova, E. E.; Kataev, E. Yu; Yashina, L. V.; Itkis, D. M.; Avdeev, M. V.

    2018-03-01

    The operation performance of electrochemical energy conversion and storage systems such as supercapacitors and batteries depends on the processes occurring at the electrochemical interfaces, where charge separation and chemical reactions occur. Here, we report about the tests of the neutron reflectometry cells specially designed for operando studies of structural changes at the electrochemical interfaces between solid electrodes and liquid electrolytes. The cells are compatible with anhydrous electrolytes with organic solvents, which are employed today in all lithium ion batteries and most supercapacitors. The sensitivity of neutron reflectometry applied at the time-of-flight (TOF) reflectometer at the pulsed reactor IBR-2 is discussed regarding the effect of solid electrolyte interphase (SEI) formation on metal electrode surface.

  5. Remote Strain Sensing of CFRP Using Microwave Frequency Domain Reflectometry

    NASA Technical Reports Server (NTRS)

    Wilson, William C.; Moore, Jason P.; Juarez, Peter D.

    2016-01-01

    NASA's Advanced Composites Project is investigating technologies that increase automated remote inspection of aircraft composite structures. Therefore, microwave Frequency Domain Reflectometry (FDR) is being investigated as a method of enabling rapid remote measurement of strain occurring at the first ply of a composite fiber reinforced polymer (CFRP) structure using Radio Frequency (RF) Electro-Magnetic (EM) radiation. While microwave reflectometry has been used to detect disbonds in CFRP structures, its use in detecting strain has been limited. This work will present data demonstrating the measurement of the reactance changes due to loading conditions that are indicative of strain in a CFRP structure. In addition, the basic EM signature will be presented along with an analysis of temperature and humidity effects.

  6. Time domain reflectometry measurements of solute transport across a soil layer boundary

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nissen, H.H.; Moldrup, P.; Kachanoski, R.G.

    2000-02-01

    The mechanisms governing solute transport through layered soil are not fully understood. Solute transport at, above, and beyond the interface between two soil layers during quasi-steady-state soil water movement was investigated using time domain reflectometry (TDR). A 0.26-m sandy loam layer was packed on top of a 1.35-m fine sand layer in a soil column. Soil water content ({theta}) and bulk soil electrical conductivity (EC{sub b}) were measured by 50 horizontal and 2 vertical TDR probes. A new TDR calibration method that gives a detailed relationship between apparent relative dielectric permittivity (K{sub s}) and {theta} was applied. Two replicate solutemore » transport experiments were conducted adding a conservative tracer (CCl) to the surface as a short pulse. The convective lognormal transfer function model (CLT) was fitted to the TDR-measured time integral-normalized resident concentration breakthrough curves (BTCs). The BTCs and the average solute-transport velocities showed preferential flow occurred across the layer boundary. A nonlinear decrease in TDR-measured {theta} in the upper soil toward the soil layer boundary suggests the existence of a 0.10-m zone where water is confined towards fingered flow, creating lateral variations in the area-averaged water flux above the layer boundary. A comparison of the time integral-normalized flux concentration measured by vertical and horizontal TDR probes at the layer boundary also indicates a nonuniform solute transport. The solute dispersivity remained constant in the upper soil layer, but increased nonlinearly (and further down, linearly) with depth in the lower layer, implying convective-dispersive solute transport in the upper soil, a transition zone just below the boundary, and stochastic-convective solute transport in the remaining part of the lower soil.« less

  7. Operando Measurement of Solid Electrolyte Interphase Formation at Working Electrode of Li-Ion Battery by Time-Slicing Neutron Reflectometry.

    PubMed

    Kawaura, Hiroyuki; Harada, Masashi; Kondo, Yasuhito; Kondo, Hiroki; Suganuma, Yoshitake; Takahashi, Naoko; Sugiyama, Jun; Seno, Yoshiki; Yamada, Norifumi L

    2016-04-20

    We report the first operando measurement of solid electrolyte interphase (SEI) formation at an electrode using in situ neutron reflectometry. The results revealed the growth of the SEI and intercalation of ions during the charge reaction. Furthermore, we propose a way of evaluating the charge used for the SEI formation.

  8. Common-path conoscopic interferometry for enhanced picosecond ultrasound detection

    NASA Astrophysics Data System (ADS)

    Liu, Liwang; Guillet, Yannick; Audoin, Bertrand

    2018-05-01

    We report on a common-path implementation of conoscopic interferometry in picosecond pump-probe reflectometry for simple and efficient detection of picosecond ultrasounds. The interferometric configuration proposed here is greatly simplified, involving only the insertion of a birefringent crystal in a standard reflectometry setup. Our approach is demonstrated by the optical detection of coherent acoustic phonons propagating through thin metal films under two representative geometries, one a particular case where the crystal slab is part of a sample as substrate of a metal film, and the other a more general case where the crystal slab is independent of the sample as part of the detection system. We first illustrate the former with a 300 nm thin film of polycrystalline titanium, deposited by physical vapor deposition on top of a 1 mm-thick uniaxial (0001) sapphire crystal. A signal-to-noise ratio (SNR) enhancement of more than 15 dB is achieved compared to conventional reflectometry. Next, the general case is demonstrated with a 900 nm-tungsten film sputtered on a silicon wafer substrate. More echoes can be discriminated by using the reported approach compared to standard reflectometry, which confirms the improvement in SNR and suggests broad applications for the reported method.

  9. Surface Reflectometry and Ionosphere Sounding from the Radar for Europa Assessment and Sounding: Ocean to Near-surface (REASON)

    NASA Astrophysics Data System (ADS)

    Grima, C.; Blankenship, D. D.; Schroeder, D. M.; Moussessian, A.; Soderlund, K. M.; Gim, Y.; Plaut, J. J.; Greenbaum, J. S.; Lopez Garcia, E.; Campbell, B. A.; Putzig, N. E.; Patterson, G.

    2015-12-01

    The Radar for Europa Assessment and Sounding: Ocean to Near-surface (REASON) has been selected for the scientific payload of a NASA's multiple flyby mission to explore the icy moon Europa. REASON is an active dual-frequency (9/60 MHz) instrument led by the University of Texas Institute for Geophysics (UTIG). It is designed to achieve multi-disciplinary measurements to investigate subsurface waters and the ice shell structure (Sounding), the surface elevation and tides (Altimetry), the surface physical properties (Reflectometry), and the ionospheric environment (Plasma/Particles). We will present the concepts behind the "Reflectometry" and "Plasma/Particles" measurements, demonstrate their efficiency with planetary analogs, and anticipate their capabilities for the exploration of Europa. We will also highlight the potential synergies with other instruments selected for the Europa mission payload.The "Reflectometry" compares the statistical behavior of the surface echo amplitudes with theoretical stochastic models to separate the reflected and scattered contributions to the signal. Once those two components are deduced they are used in a backscattering model to invert surface properties such as roughness, density, and/or impurity load. "Reflectometry" measurements will contribute to the statistical characterization of the surface over ~ 10-km-long areas with a ~ 10 m skin depth for geological investigation, near-surface brine detection, plume-deposited snow characterization, and landing site reconnaissance. The "Plasma/Particles" measurement relies on the dispersive signal delays induced by the ionospheric content integrated along the radio propagation path. Correction of this delay with existing techniques provides the total electron content below the spacecraft. "Plasma/Particles" measurements will constrain the ionosphere's shape and variability along the acquisition track and might detect transient plume-induced ionosphere when active.

  10. Optical detection dental disease using polarized light

    DOEpatents

    Everett, Matthew J.; Colston, Jr., Billy W.; Sathyam, Ujwal S.; Da Silva, Luiz B.; Fried, Daniel

    2003-01-01

    A polarization sensitive optical imaging system is used to detect changes in polarization in dental tissues to aid the diagnosis of dental disease such as caries. The degree of depolarization is measured by illuminating the dental tissue with polarized light and measuring the polarization state of the backscattered light. The polarization state of this reflected light is analyzed using optical polarimetric imaging techniques. A hand-held fiber optic dental probe is used in vivo to direct the incident beam to the dental tissue and collect the reflected light. To provide depth-resolved characterization of the dental tissue, the polarization diagnostics may be incorporated into optical coherence domain reflectometry and optical coherence tomography (OCDR/OCT) systems, which enables identification of subsurface depolarization sites associated with demineralization of enamel or bone.

  11. Application of time–frequency wavelet analysis in the reflectometry of thin films

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Astaf’ev, S. B., E-mail: bard@crys.ras.ru; Shchedrin, B. M.; Yanusova, L. G.

    2017-03-15

    The application of time–frequency wavelet analysis for solving the reflectometry inverse problem is considered. It is shown that a simultaneous transform of specular intensity curve, depending on the grazing angle and spatial frequency, allows one to determine not only the thickness but also the alteration order of individual regions (layers) with characteristic behavior of electron density. This information makes it possible to reconstruct the electron density profile in the film cross section as a whole (i.e., to solve the inverse reflectometry problem). The application of the time–frequency transform is illustrated by examples of reconstructing (based on X-ray reflectivity data) themore » layer alternation order in models of two-layer films with inverted arrangement of layers and a four-layer film on a solid substrate.« less

  12. Isotope-Identifying neutron reflectometry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nikitenko, Yu. V., E-mail: nikiten@nf.jinr.ru; Petrenko, A. V.; Gundorin, N. A.

    2015-07-15

    The possibilities of an isotope-indentifying study of layered structures in different regimes of a neutron wave field are considered. The detection of specularly reflected neutrons and secondary radiation (caused by neutron capture) in the form of charged particles, γ quanta, and nuclear fission fragments, as well as neutrons spin-flipped in a noncollinear magnetic field and on nuclei of elements with spin, makes it possible to implement isotope-indentifying neutron reflectometry.

  13. Er:Yb phosphate glass laser with nonlinear absorber for phase-sensitive optical time domain reflectometry

    NASA Astrophysics Data System (ADS)

    Zhirnov, A. A.; Pnev, A. B.; Svelto, C.; Norgia, M.; Pesatori, A.; Galzerano, G.; Laporta, P.; Shelestov, D. A.; Karasik, V. E.

    2017-11-01

    A novel laser for phase-sensitive optical time-domain reflectometry (Φ-OTDR) is presented. The advantages of a compact solid-state laser are listed, current problems are shown. Experiments with a microchip single-optical-element laser, from setup construction to usage in Φ-OTDR system, are presented. New laser scheme with two-photon intracavity absorber is suggested and its advantages are described.

  14. Application of reflectometry power flow for magnetic field pitch angle measurements in tokamak plasmas (invited).

    PubMed

    Gourdain, P-A; Peebles, W A

    2008-10-01

    Reflectometry has successfully demonstrated measurements of many important parameters in high temperature tokamak fusion plasmas. However, implementing such capabilities in a high-field, large plasma, such as ITER, will be a significant challenge. In ITER, the ratio of plasma size (meters) to the required reflectometry source wavelength (millimeters) is significantly larger than in existing fusion experiments. This suggests that the flow of the launched reflectometer millimeter-wave power can be realistically analyzed using three-dimensional ray tracing techniques. The analytical and numerical studies presented will highlight the fact that the group velocity (or power flow) of the launched microwaves is dependent on the direction of wave propagation relative to the internal magnetic field. It is shown that this dependence strongly modifies power flow near the cutoff layer in a manner that embeds the local magnetic field direction in the "footprint" of the power returned toward the launch antenna. It will be shown that this can potentially be utilized to locally determine the magnetic field pitch angle at the cutoff location. The resultant beam drift and distortion due to magnetic field and relativistic effects also have significant consequences on the design of reflectometry systems for large, high-field fusion experiments. These effects are discussed in the context of the upcoming ITER burning plasma experiment.

  15. Global mapping of stratigraphy of an old-master painting using sparsity-based terahertz reflectometry.

    PubMed

    Dong, Junliang; Locquet, Alexandre; Melis, Marcello; Citrin, D S

    2017-11-08

    The process by which art paintings are produced typically involves the successive applications of preparatory and paint layers to a canvas or other support; however, there is an absence of nondestructive modalities to provide a global mapping of the stratigraphy, information that is crucial for evaluation of its authenticity and attribution, for insights into historical or artist-specific techniques, as well as for conservation. We demonstrate sparsity-based terahertz reflectometry can be applied to extract a detailed 3D mapping of the layer structure of the 17th century easel painting Madonna in Preghiera by the workshop of Giovanni Battista Salvi da Sassoferrato, in which the structure of the canvas support, the ground, imprimatura, underpainting, pictorial, and varnish layers are identified quantitatively. In addition, a hitherto unidentified restoration of the varnish has been found. Our approach unlocks the full promise of terahertz reflectometry to provide a global and detailed account of an easel painting's stratigraphy by exploiting the sparse deconvolution, without which terahertz reflectometry in the past has only provided a meager tool for the characterization of paintings with paint-layer thicknesses smaller than 50 μm. The proposed modality can also be employed across a broad range of applications in nondestructive testing and biomedical imaging.

  16. Multi-modality endoscopic imaging for the detection of colorectal cancer

    NASA Astrophysics Data System (ADS)

    Wall, Richard Andrew

    Optical coherence tomography (OCT) is an imaging method that is considered the optical analog to ultrasound, using the technique of optical interferometry to construct two-dimensional depth-resolved images of tissue microstructure. With a resolution on the order of 10 um and a penetration depth of 1-2 mm in highly scattering tissue, fiber optics-coupled OCT is an ideal modality for the inspection of the mouse colon with its miniaturization capabilities. In the present study, the complementary modalities laser-induced fluorescence (LIF), which offers information on the biochemical makeup of the tissue, and surface magnifying chromoendoscopy, which offers high contrast surface visualization, are combined with OCT in endoscopic imaging systems for the greater specificity and sensitivity in the differentiation between normal and neoplastic tissue, and for the visualization of biomarkers which are indicative of early events in colorectal carcinogenesis. Oblique incidence reflectometry (OIR) also offers advantages, allowing the calculation of bulk tissue optical properties for use as a diagnostic tool. The study was broken up into three specific sections. First, a dual-modality OCTLIF imaging system was designed, capable of focusing light over 325-1300 nm using a reflective distal optics design. A dual-modality fluorescence-based SMC-OCT system was then designed and constructed, capable of resolving the stained mucosal crypt structure of the in vivo mouse colon. The SMC-OCT instrument's OIR capabilities were then modeled, as a modified version of the probe was used measure tissue scattering and absorption coefficients.

  17. Characterization of human scalp hairs by optical low-coherence reflectometry

    NASA Astrophysics Data System (ADS)

    Wang, X. J.; Milner, T. E.; Dhond, R. P.; Sorin, W. V.; Newton, S. A.; Nelson, J. S.

    1995-03-01

    Optical low-coherence reflectometry is used to investigate the internal structure and optical properties of human scalp hair. Regardless of hair color, the refractive index of the cortical region remains within the range of 1.56-1.59. The amplitude of the backscattered infrared light coupled into different-colored hair confirms the relative melanin content. Discontinuities in the refractive index permit identification of distinct structural layers within the hair shaft.

  18. Experimental Test of Coupled Wave Model of Large Coils

    DTIC Science & Technology

    1985-06-01

    46556 Abstract: Recent data from Time Domain Pulse Reflectometry experiments on a three turn coil in the form of a race track corroborate the...Domain Pulse Reflectometry experiments on a three turn coil in the form of a race track corroborate the theory of coupled wave model for large coils...Gabriel, "Coupled Wave Model for Large Magnet Coils", NASA Contractor Report 3332, National Aeronautics and Space Administration, Washington, DC

  19. Distributed strain measurements using fiber Bragg gratings in small-diameter optical fiber and low-coherence reflectometry.

    PubMed

    Coric, Dragan; Lai, Marco; Botsis, John; Luo, Aiping; Limberger, Hans G

    2010-12-06

    Optical low coherence reflectometry and fiber Bragg gratings written in small diameter (50 micrometer) optical fibers were used for measurements of non-homogenous internal strain fields inside an epoxy specimen with sub-grating length resolution. The results were compared with measurements using Fiber Bragg gratings in standard size (125 micrometer) single mode fibers and show that smaller fibers are less intrusive at stress heterogeneities.

  20. Pulse reflectometry as an acoustical inverse problem: Regularization of the bore reconstruction

    NASA Astrophysics Data System (ADS)

    Forbes, Barbara J.; Sharp, David B.; Kemp, Jonathan A.

    2002-11-01

    The theoretical basis of acoustic pulse reflectometry, a noninvasive method for the reconstruction of an acoustical duct from the reflections measured in response to an input pulse, is reviewed in terms of the inversion of the central Fredholm equation. It is known that this is an ill-posed problem in the context of finite-bandwidth experimental signals. Recent work by the authors has proposed the truncated singular value decomposition (TSVD) in the regularization of the transient input impulse response, a non-measurable quantity from which the spatial bore reconstruction is derived. In the present paper we further emphasize the relevance of the singular system framework to reflectometry applications, examining for the first time the transient bases of the system. In particular, by varying the truncation point for increasing condition numbers of the system matrix, it is found that the effects of out-of-bandwidth singular functions on the bore reconstruction can be systematically studied.

  1. New signal processing technique for density profile reconstruction using reflectometry.

    PubMed

    Clairet, F; Ricaud, B; Briolle, F; Heuraux, S; Bottereau, C

    2011-08-01

    Reflectometry profile measurement requires an accurate determination of the plasma reflected signal. Along with a good resolution and a high signal to noise ratio of the phase measurement, adequate data analysis is required. A new data processing based on time-frequency tomographic representation is used. It provides a clearer separation between multiple components and improves isolation of the relevant signals. In this paper, this data processing technique is applied to two sets of signals coming from two different reflectometer devices used on the Tore Supra tokamak. For the standard density profile reflectometry, it improves the initialization process and its reliability, providing a more accurate profile determination in the far scrape-off layer with density measurements as low as 10(16) m(-1). For a second reflectometer, which provides measurements in front of a lower hybrid launcher, this method improves the separation of the relevant plasma signal from multi-reflection processes due to the proximity of the plasma.

  2. Estimation of sea level variations with GPS/GLONASS-reflectometry technique

    NASA Astrophysics Data System (ADS)

    Padokhin, A. M.; Kurbatov, G. A.; Andreeva, E. S.; Nesterov, I. A.; Nazarenko, M. O.; Berbeneva, N. A.; Karlysheva, A. V.

    2017-11-01

    In the present paper we study GNSS - reflectometry methods for estimation of sea level variations using a single GNSSreceiver, which are based on the multipath propagation effects caused by the reflection of navigational signals from the sea surface. Such multipath propagation results in the appearance of the interference pattern in the Signal-to-Noise Ratio (SNR) of GNSS signals at small satellite elevation angles, which parameters are determined by the wavelength of the navigational signal and height of the antenna phase center above the reflecting sea surface. In current work we used GPS and GLONASS signals and measurements at two working frequencies of both systems to study sea level variations which almost doubles the amount of observations compared to GPS-only tide gauge. For UNAVCO sc02 station and collocated Friday Harbor NOAA tide gauge we show good agreement between GNSS-reflectometry and traditional mareograph sea level data.

  3. Carbon Fiber TOW Angle Determination Using Microwave Reflectometry

    NASA Technical Reports Server (NTRS)

    Wilson, William C.; Moore, Jason P.; Juarez, Peter D.

    2016-01-01

    NASA's Advanced Composites Project is investigating technologies that increase automated remote inspection of aircraft composite structures. Therefore, microwave Frequency Domain Reflectometry (FDR) is being investigated as a method of enabling rapid remote inspection of angular orientation of the tow using microwave radiation. This work will present preliminary data demonstrating that frequency shifts in the reflection spectrum of a carbon fiber tow sample are indicative of the angle of the tow with respect to an interrogating antenna's linear polarized output.

  4. Materials on the International Space Station Experiment (MISSE): Optical Analysis of Molecular Contamination on PEC1 Tray 2

    DTIC Science & Technology

    2007-02-20

    ellipsome- try and reflectometry were employed to show that the silicon wafers gained about a 420-A-thick layer of a silica-like con- taminant with BRDF...under Contract No. FA8802-04-C-0001. 111°. Contents I. Introduction .1 2. Ellipsometry and Reflectometry ... NASA ) I ;d~ ~ ---- ! Y Figure 2. MISSE I PECI Tray 2 facing away from Soyuz. (Courtesy NASA ) Among the samples mounted in PEC I Tray 2 were several

  5. Nd:YAG-laser-based time-domain reflectometry measurements of the intrinsic reflection signature from PMMA fiber splices

    NASA Astrophysics Data System (ADS)

    Lawson, Christopher M.; Michael, Robert R., Jr.; Dressel, Earl M.; Harmony, David W.

    1991-12-01

    Optical time domain reflectometry (OTDR) measurements have been performed on polished polymethylmethacrylate (PMMA) plastic fiber splices. After the dominant splice reflection sources due to surface roughness, inexact index matching, and fiber core misalignment were eliminated, an intrinsic OTDR signature 3 - 8 dB above the Rayleigh backscatter floor remained with all tested fibers. This minimum splice reflectivity exhibits characteristics that are consistent with sub-surface polymer damage and can be used for detection of PMMA fiber splices.

  6. The study of dielectric relaxation in aqueous carbohydrates solutions using time domain reflectometry technique

    NASA Astrophysics Data System (ADS)

    Hudge, Pravin G.; Lokhande, Milind P.; Kumbharkhane, Ashok C.

    2012-09-01

    Complex permittivity spectra of aqueous solutions of monosaccharide ( d-glucose) and disaccharides ( d-sucrose) in the frequency range from 10 MHz to 30 GHz at various concentrations and temperatures have been determined using time domain reflectometry technique. The complex dielectric permittivity spectrum of d-glucose and d-sucrose in water shows Cole-Davidson type behaviour. Dielectric constant (ɛ0) and relaxation time (τ), Kirkwood correlation factor, activation enthalpy and entropy parameters have been determined.

  7. Comparison of ocular biometric measurements between a new swept-source optical coherence tomography and a common optical low coherence reflectometry.

    PubMed

    Gao, Rongrong; Chen, Hao; Savini, Giacomo; Miao, Yaxin; Wang, Xiaorui; Yang, Jing; Zhao, Weiqi; Wang, Qinmei; Huang, Jinhai

    2017-05-30

    The purpose of the current study was to compare the measurements between a new optical biometer based on swept-source optical coherence tomography (SS-OCT), the OA-2000 (Tomey, Japan), and an optical biometer based on optical low coherence reflectometry (OLCR), the Lenstar (Haag-Streit, Switzerland). Ninety-nine eyes of 99 healthy subjects were included. The axial length (AL), central corneal thickness (CCT), anterior chamber depth (ACD), aqueous depth (AD), lens thickness (LT), keratometry (K) readings, including flat K (Kf), steep K (Ks), mean K (Km), astigmatism vectors J 0 , J 45 at diameters of 2.5 and 3.0 mm, and white-to-white diameter (WTW) were measured three times each using both biometer in normal eyes by random sequence. Bland-Altman analysis showed good agreement between the SS-OCT and OLCR devices for AL, AD, ACD, LT, with narrow 95% LoA (-0.05 to 0.07 mm, -0.09 to 0.10 mm, -0.10 to 0.09 mm, and -0.06 to 0.22 mm, respectively), and the P values of ACD were both >0.05. The CCT, Kf, Ks, Km, J 0 , J 45 and WTW values provided by the OA-2000 were in good agreement with the Lenstar, and statistically significant differences were detected for some of them but not clinical differences. The agreement was excellent especially for AL.

  8. Influence of ibuprofen on phospholipid membranes

    NASA Astrophysics Data System (ADS)

    Jaksch, Sebastian; Lipfert, Frederik; Koutsioubas, Alexandros; Mattauch, Stefan; Holderer, Olaf; Ivanova, Oxana; Frielinghaus, Henrich; Hertrich, Samira; Fischer, Stefan F.; Nickel, Bert

    2015-02-01

    A basic understanding of biological membranes is of paramount importance as these membranes comprise the very building blocks of life itself. Cells depend in their function on a range of properties of the membrane, which are important for the stability and function of the cell, information and nutrient transport, waste disposal, and finally the admission of drugs into the cell and also the deflection of bacteria and viruses. We have investigated the influence of ibuprofen on the structure and dynamics of L-α -phosphatidylcholine (SoyPC) membranes by means of grazing incidence small-angle neutron scattering, neutron reflectometry, and grazing incidence neutron spin echo spectroscopy. From the results of these experiments, we were able to determine that ibuprofen induces a two-step structuring behavior in the SoyPC films, where the structure evolves from the purely lamellar phase for pure SoyPC over a superposition of two hexagonal phases to a purely hexagonal phase at high concentrations. A relaxation, which is visible when no ibuprofen is present in the membrane, vanishes upon addition of ibuprofen. This we attribute to a stiffening of the membrane. This behavior may be instrumental in explaining the toxic behavior of ibuprofen in long-term application.

  9. Analysis of buried interfaces in multilayer mirrors using grazing incidence extreme ultraviolet reflectometry near resonance edges.

    PubMed

    Sertsu, M G; Nardello, M; Giglia, A; Corso, A J; Maurizio, C; Juschkin, L; Nicolosi, P

    2015-12-10

    Accurate measurements of optical properties of multilayer (ML) mirrors and chemical compositions of interdiffusion layers are particularly challenging to date. In this work, an innovative and nondestructive experimental characterization method for multilayers is discussed. The method is based on extreme ultraviolet (EUV) reflectivity measurements performed on a wide grazing incidence angular range at an energy near the absorption resonance edge of low-Z elements in the ML components. This experimental method combined with the underlying physical phenomenon of abrupt changes of optical constants near EUV resonance edges enables us to characterize optical and structural properties of multilayers with high sensitivity. A major advantage of the method is to perform detailed quantitative analysis of buried interfaces of multilayer structures in a nondestructive and nonimaging setup. Coatings of Si/Mo multilayers on a Si substrate with period d=16.4  nm, number of bilayers N=25, and different capping structures are investigated. Stoichiometric compositions of Si-on-Mo and Mo-on-Si interface diffusion layers are derived. Effects of surface oxidation reactions and carbon contaminations on the optical constants of capping layers and the impact of neighboring atoms' interactions on optical responses of Si and Mo layers are discussed.

  10. Birefringence in anisotropic optical fibres studied by polarised light Brillouin reflectometry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Smirnov, A S; Burdin, V V; Konstantinov, Yu A

    2015-01-31

    Modal birefringence (the difference between the effective refractive indices of orthogonal polarisation modes) is one of the key parameters of anisotropic single-mode fibres, characterising their ability to preserve a linearly polarised state of input light. This parameter is commonly measured using short pieces of fibre, but such procedures are destructive and allow the birefringence to be determined only at the ends of long fibres. In this study, polarised light Brillouin reflectometry is used to assess birefringence uniformity throughout the length of an anisotropic fibre. (optical fibres)

  11. High-resolution high-sensitivity and truly distributed optical frequency domain reflectometry for structural crack detection

    NASA Astrophysics Data System (ADS)

    Li, Wenhai; Bao, Xiaoyi; Chen, Liang

    2014-05-01

    Optical Frequency Domain Reflectometry (OFDR) with the use of polarization maintaining fiber (PMF) is capable of distinguishing strain and temperature, which is critical for successful field applications such as structural health monitoring (SHM) and smart material. Location-dependent measurement sensitivities along PMF are compensated by cross- and auto-correlations measurements of the spectra form a distributed parameter matrix. Simultaneous temperature and strain measurement accuracy of 1μstrain and 0.1°C is achieved with 2.5mm spatial resolution in over 180m range.

  12. Method and Apparatus for Monitoring the Integrity of a Geomembrane Liner using time Domain Reflectometry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Morris, John L.

    1998-11-09

    Leaks are detected in a multi-layered geomembrane liner by a two-dimensional time domain reflectometry (TDR) technique. The TDR geomembrane liner is constructed with an electrically conductive detection layer positioned between two electrically non-conductive dielectric layers, which are each positioned between the detection layer and an electrically conductive reference layer. The integrity of the TDR geomembrane liner is determined by generating electrical pulses within the detection layer and measuring the time delay for any reflected electrical energy caused by absorption of moisture by a dielectric layer.

  13. Method and apparatus for monitoring the integrity of a geomembrane liner using time domain reflectometry

    DOEpatents

    Morrison, John L [Idaho Falls, ID

    2001-04-24

    Leaks are detected in a multi-layered geomembrane liner by a two-dimensional time domain reflectometry (TDR) technique. The TDR geomembrane liner is constructed with an electrically conductive detection layer positioned between two electrically non-conductive dielectric layers, which are each positioned between the detection layer and an electrically conductive reference layer. The integrity of the TDR geomembrane liner is determined by generating electrical pulses within the detection layer and measuring the time delay for any reflected electrical energy caused by absorption of moisture by a dielectric layer.

  14. Pinpointing chiral structures with front-back polarized neutron reflectometry.

    PubMed

    O'Donovan, K V; Borchers, J A; Majkrzak, C F; Hellwig, O; Fullerton, E E

    2002-02-11

    A new development in spin-polarized neutron reflectometry enables us to more fully characterize the nucleation and growth of buried domain walls in layered magnetic materials. We applied this technique to a thin-film exchange-spring magnet. After first measuring the reflectivity with the neutrons striking the front, we measure with the neutrons striking the back. Simultaneous fits are sensitive to the presence of spiral spin structures. The technique reveals previously unresolved features of field-dependent domain walls in exchange-spring systems and has sufficient generality to apply to a variety of magnetic systems.

  15. Polarization properties and microfacet-based modelling of white, grey and coloured matte diffuse reflection standards

    NASA Astrophysics Data System (ADS)

    Quast, T.; Schirmacher, A.; Hauer, K.-O.; Koo, A.

    2018-02-01

    To elucidate the influence of polarization in diffuse reflectometry, we performed a series of measurements in several bidirectional geometries and determined the Stokes parameters of the diffusely reflected radiation. Different types of matte reflection standards were used, including several common white standards and ceramic colour standards. The dependence of the polarization on the sample type, wavelength and geometry have been studied systematically, the main influence factors have been identified: The effect is largest at large angles of incidence or detection and at wavelengths where the magnitude of the reflectance is small. The results for the colour standards have been modelled using a microfacet-based reflection theory which is derived from the well-known model of Torrance and Sparrow. Although the theory is very simple and only has three free parameters, the agreement with the measured data is very good, all essential features of the data can be reproduced by the model.

  16. The change in color matches with retinal angle of incidence of the colorimeter beams.

    PubMed

    Alpern, M; Kitahara, H; Fielder, G H

    1987-01-01

    Differences between W.D.W. chromaticities of monochromatic lights obtained with all colorimeter beams incident on the retina "off-axis" and those found for lights striking the retina normally have been studied throughout the visible spectrum on 4 normal trichromats. The results are inconsistent with: (i) the assumption in Weale's theories of the Stiles-Crawford hue shift that the sets of absorption spectra of the visual pigments catching normally and obliquely incident photons are identical, and (ii) "self-screening" explanations for the change in color with angle of incidence on the retina. The color matching functions of a protanomalous trichromat are inconsistent with the hypothesis that the absorption spectra of the visual pigments catching normally incident photons in his retina are those catching obliquely incident photons in the normal retina.

  17. Improved time-frequency analysis of ASDEX Upgrade reflectometry data using the reassigned spectrogram technique.

    PubMed

    Varela, P; Silva, A; da Silva, F; da Graça, S; Manso, M E; Conway, G D

    2010-10-01

    The spectrogram is one of the best-known time-frequency distributions suitable to analyze signals whose energy varies both in time and frequency. In reflectometry, it has been used to obtain the frequency content of FM-CW signals for density profile inversion and also to study plasma density fluctuations from swept and fixed frequency data. Being implemented via the short-time Fourier transform, the spectrogram is limited in resolution, and for that reason several methods have been developed to overcome this problem. Among those, we focus on the reassigned spectrogram technique that is both easily automated and computationally efficient requiring only the calculation of two additional spectrograms. In each time-frequency window, the technique reallocates the spectrogram coordinates to the region that most contributes to the signal energy. The application to ASDEX Upgrade reflectometry data results in better energy concentration and improved localization of the spectral content of the reflected signals. When combined with the automatic (data driven) window length spectrogram, this technique provides improved profile accuracy, in particular, in regions where frequency content varies most rapidly such as the edge pedestal shoulder.

  18. Radial and poloidal correlation reflectometry on Experimental Advanced Superconducting Tokamak

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Qu, Hao; Zhang, Tao; Han, Xiang

    2015-08-15

    An X-mode polarized V band (50 GHz–75 GHz) radial and poloidal correlation reflectometry is designed and installed on Experimental Advanced Superconducting Tokamak (EAST). Two frequency synthesizers (12 GHz–19 GHz) are used as sources. Signals from the sources are up-converted to V band using active quadruplers and then coupled together for launching through one single pyramidal antenna. Two poloidally separated antennae are installed to receive the reflected waves from plasma. This reflectometry system can be used for radial and poloidal correlation measurement of the electron density fluctuation. In ohmically heated plasma, the radial correlation length is about 1.5 cm measured bymore » the system. The poloidal correlation analysis provides a means to estimate the fluctuation velocity perpendicular to the main magnetic field. In the present paper, the distance between two poloidal probing points is calculated with ray-tracing code and the propagation time is deduced from cross-phase spectrum. Fluctuation velocity perpendicular to the main magnetic field in the core of ohmically heated plasma is about from −1 km/s to −3 km/s.« less

  19. The SGR-ReSI and its application for GNSS reflectometry on the NASA EV-2 CYGNSS mission

    NASA Astrophysics Data System (ADS)

    Unwin, M.; Jales, P.; Blunt, P.; Duncan, S.; Brummitt, M.; Ruf, C.

    As part of the EV-2 Cyclone Global Navigation Satellite System (CYGNSS) mission team, Surrey will be providing the Delay Doppler Mapping Instrument (DDMI) for eight Observatories designed and built by the University of Michigan and Southwest Research Institute (SwRI). Following the success of the GPS Reflectometry Experiment on the UK-DMC 1 satellite launched in 2003, Surrey has developed the SGR-ReSI as a move towards operational reflectometry and other applications. The Space GPS Receiver Remote Sensing Instrument (SGR-ReSI) is a COTS-electronics based GNSS receiver which can support up to eight programmable front-ends. It allows collection of raw sampled data but also is capable of processing the reflections into Delay Doppler Maps in real time. The first flight of the SGR-ReSI will be on the UK TechDemoSat-1 to prove the instrument and its various applications. The SGR-ReSI on CYGNSS has a different configuration to that on TechDemoSat-1 which is needed to focus on the requirements for operational cyclone sensing.

  20. Effects of strain and buffer layer on interfacial magnetization in Sr 2 CrReO 6 films determined by polarized neutron reflectometry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, Yaohua; Lucy, J. M.; Glavic, A.

    2014-09-01

    We have determined the depth-resolved magnetization structures of a series of highly orderedSr2CrReO6 (SCRO) ferrimagnetic epitaxial films via combined studies of x-ray reflectometry, polarized neutron reflectometry and SQUID magnetometry. The SCRO films deposited directly on (LaAlO3)0:3(Sr2AlTaO6)0:7 or SrTiO3 substrates show reduced magnetization of similar width near the interfaces with the substrates, despite having different degrees of strain. When the SCRO film is deposited on a Sr2CrNbO6 (SCNO) double perovskite buffer layer, the width the interfacial region with reduced magnetization is reduced, agreeing with an improved Cr/Re ordering. However, the relative reduction of the magnetization averaged over the interfacial regions aremore » comparable among the three samples. Interestingly, we found that the magnetization suppression region is wider than the Cr/Re antisite disorder region at the interface between SCRO and SCNO.« less

  1. Low-noise heterodyne receiver for electron cyclotron emission imaging and microwave imaging reflectometry

    NASA Astrophysics Data System (ADS)

    Tobias, B.; Domier, C. W.; Luhmann, N. C.; Luo, C.; Mamidanna, M.; Phan, T.; Pham, A.-V.; Wang, Y.

    2016-11-01

    The critical component enabling electron cyclotron emission imaging (ECEI) and microwave imaging reflectometry (MIR) to resolve 2D and 3D electron temperature and density perturbations is the heterodyne imaging array that collects and downconverts radiated emission and/or reflected signals (50-150 GHz) to an intermediate frequency (IF) band (e.g. 0.1-18 GHz) that can be transmitted by a shielded coaxial cable for further filtering and detection. New circuitry has been developed for this task, integrating gallium arsenide (GaAs) monolithic microwave integrated circuits (MMICs) mounted on a liquid crystal polymer (LCP) substrate. The improved topology significantly increases electromagnetic shielding from out-of-band interference, leads to 10× improvement in the signal-to-noise ratio, and dramatic cost savings through integration. The current design, optimized for reflectometry and edge radiometry on mid-sized tokamaks, has demonstrated >20 dB conversion gain in upper V-band (60-75 GHz). Implementation of the circuit in a multi-channel electron cyclotron emission imaging (ECEI) array will improve the diagnosis of edge-localized modes and fluctuations of the high-confinement, or H-mode, pedestal.

  2. Low-noise heterodyne receiver for electron cyclotron emission imaging and microwave imaging reflectometry.

    PubMed

    Tobias, B; Domier, C W; Luhmann, N C; Luo, C; Mamidanna, M; Phan, T; Pham, A-V; Wang, Y

    2016-11-01

    The critical component enabling electron cyclotron emission imaging (ECEI) and microwave imaging reflectometry (MIR) to resolve 2D and 3D electron temperature and density perturbations is the heterodyne imaging array that collects and downconverts radiated emission and/or reflected signals (50-150 GHz) to an intermediate frequency (IF) band (e.g. 0.1-18 GHz) that can be transmitted by a shielded coaxial cable for further filtering and detection. New circuitry has been developed for this task, integrating gallium arsenide (GaAs) monolithic microwave integrated circuits (MMICs) mounted on a liquid crystal polymer (LCP) substrate. The improved topology significantly increases electromagnetic shielding from out-of-band interference, leads to 10× improvement in the signal-to-noise ratio, and dramatic cost savings through integration. The current design, optimized for reflectometry and edge radiometry on mid-sized tokamaks, has demonstrated >20 dB conversion gain in upper V-band (60-75 GHz). Implementation of the circuit in a multi-channel electron cyclotron emission imaging (ECEI) array will improve the diagnosis of edge-localized modes and fluctuations of the high-confinement, or H-mode, pedestal.

  3. Separation and correlation of structural and magnetic roughness in a Ni thin film by polarized off-specular neutron reflectometry.

    PubMed

    Singh, Surendra; Basu, Saibal

    2009-02-04

    Diffuse (off-specular) neutron and x-ray reflectometry has been used extensively for the determination of interface morphology in solids and liquids. For neutrons, a novel possibility is off-specular reflectometry with polarized neutrons to determine the morphology of a magnetic interface. There have been few such attempts due to the lower brilliance of neutron sources, though magnetic interaction of neutrons with atomic magnetic moments is much easier to comprehend and easily tractable theoretically. We have obtained a simple and physically meaningful expression, under the Born approximation, for analyzing polarized diffuse (off-specular) neutron reflectivity (PDNR) data. For the first time PDNR data from a Ni film have been analyzed and separate chemical and magnetic morphologies have been quantified. Also specular polarized neutron reflectivity measurements have been carried out to measure the magnetic moment density profile of the Ni film. The fit to PDNR data results in a longer correlation length for in-plane magnetic roughness than for chemical (structural) roughness. The magnetic interface is smoother than the chemical interface.

  4. Surface physics with cold and thermal neutron reflectometry. Progress report, April 1, 1991--September 30, 1993

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Steyerl, A.

    1993-09-01

    Within the past two and one half years of the project ``Surface Physics With Cold and Thermal Neutron Reflectometry`` a new thermal neutron reflectometer was constructed at the Rhode Island Nuclear Science Center (RINSC). It was used to study various liquid and solid surfaces. Furthermore, neutron reflection experiments were be un at different laboratories in collaboration with Dr. G.P. Fetcher (at Argonne National Laboratory), Dr. T. Russell (IBM Almaden) and Drs. S.K. Satija and A. Karim (at the National Institute for Standards and Technology). The available resources allowed partial construction of an imaging system for ultracold neutrons. It is expectedmore » to provide an extremely high resolution in momentum and energy transfer in surface studies using neutron reflectometry. Much of the work reported here was motivated by the possibility of later implementation at the planned Advanced Neutron Source at Oak Ridge. In a separate project the first concrete plans for an intense source of ultracold neutrons for the Advanced Neutron Source were developed.« less

  5. Case study on the dynamics of ultrafast laser heating and ablation of gold thin films by ultrafast pump-probe reflectometry and ellipsometry

    NASA Astrophysics Data System (ADS)

    Pflug, T.; Wang, J.; Olbrich, M.; Frank, M.; Horn, A.

    2018-02-01

    To increase the comprehension of ultrafast laser ablation, the ablation process has to be portrayed with sufficient temporal resolution. For example, the temporal modification of the complex refractive index {\\tilde{n}} and the relative reflectance of a sample material after irradiation with ultrafast single-pulsed laser radiation can be measured with a pump-probe setup. This work describes the construction and validation of a pump-probe setup enabling spatially, temporally, and spectroscopically resolved Brewster angle microscopy, reflectometry, ellipsometry, and shadow photography. First pump-probe reflectometry and ellipsometry measurements are performed on gold at λ _{probe}= 440 nm and three fluences of the single-pulsed pump radiation at λ _{pump}= 800 nm generating no, gentle, and strong ablation. The relative reflectance overall increases at no and gentle ablation. At strong ablation, the relative reflectance locally decreases, presumable caused by emitted thermal electrons, ballistic electrons, and ablating material. The refractive index n is slightly decreasing after excitation, while the extinction coefficient k is increasing.

  6. Chaotic optical time-domain reflectometry using a distributed feedback laser diode modulated by an improved Colpitts oscillator

    NASA Astrophysics Data System (ADS)

    Li, Jing Xia; Xu, Hang; Liu, Li; Su, Peng Cheng; Zhang, Jian Guo

    2015-05-01

    We report a chaotic optical time-domain reflectometry for fiber fault location, where a chaotic probe signal is generated by driving a distributed feedback laser diode with an improved Colpitts chaotic oscillator. The results show that the unterminated fiber end, the loose connector, and the mismatch connector can be precisely located. A measurement range of approximately 91 km and a range independent resolution of 6 cm are achieved. This implementation method is easy to integrate and is cost effective, which gives it great potential for commercial applications.

  7. Simulation of reflectometry Bragg backscattering spectral responses in the absence of a cutoff layer.

    PubMed

    da Silva, F; da Graça, S; Heuraux, S; Conway, G D

    2010-10-01

    Experimental reflectometry signals obtained in the absence of a cutoff layer, with the possibility of interferometric operation excluded, show a coherent and recurrent frequency spectrum signature similar to an Alfvén cascade signature. A possible explanation resides in the modulation of a resonant Bragg backscattering response by an Alfvén mode structure located at the center of the plasma whose frequency of oscillation modulates the backscattered signal in a conformable way. This situation is modeled and simulated using an O-mode full-wave Maxwell finite-difference time-domain code and the resulting signatures are discussed.

  8. Measurement of shear-wave velocity by ultrasound critical-angle reflectometry (UCR).

    PubMed

    Mehta, S; Antich, P

    1997-01-01

    There exists a growing body of research that relates the measurement of pressure-wave velocity in bone to different physiological conditions and treatment modalities. The shear-wave velocity has been less studied, although it is necessary for a more complete understanding of the mechanical properties of bone. Ultrasound critical-angle reflectometry (UCR) is a noninvasive and nondestructive technique previously used to measure pressure-wave velocities both in vitro and in vivo. This note describes its application to the measurement of shear-wave velocity in bone, whether directly accessible or covered by soft tissue.

  9. Dental optical coherence domain reflectometry explorer

    DOEpatents

    Everett, Matthew J.; Colston, Jr., Billy W.; Sathyam, Ujwal S.; Da Silva, Luiz B.

    2001-01-01

    A hand-held, fiber optic based dental device with optical coherence domain reflectometry (OCDR) sensing capabilities provides a profile of optical scattering as a function of depth in the tissue at the point where the tip of the dental explorer touches the tissue. This system provides information on the internal structure of the dental tissue, which is then used to detect caries and periodontal disease. A series of profiles of optical scattering or tissue microstructure are generated by moving the explorer across the tooth or other tissue. The profiles are combined to form a cross-sectional, or optical coherence tomography (OCT), image.

  10. Structure analysis of aqueous ferrofluids at interface with silicon: neutron reflectometry data

    NASA Astrophysics Data System (ADS)

    Gapon, I. V.; Petrenko, V. I.; Bulavin, L. A.; Balasoiu, M.; Kubovcikova, M.; Zavisova, V.; Koneracka, M.; Kopcansky, P.; Chiriac, H.; Avdeev, M. V.

    2017-05-01

    Adsorption of nanoparticles from aqueous ferrofluids (FFs) on solid surface (crystalline silicon) was studied by neutron reflectometry (NR). Two kinds of FFs were considered. First kind was heavy water-based ferrofluids with magnetite nanoparticles coated by double layer of sodium oleate. Second one FF was cobalt ferrite nanoparticles stabilized by lauric acid/sodium n-dodecylsulphate layer and dispersed in water. It was obtained only a single adsorption layer for two types of ferrofluids. The impact of the magnetic nanoparticles concentration and geometry was considered in frame of the adsorption characteristic of FFs.

  11. Measurement of shear-wave velocity by ultrasound critical-angle reflectometry (UCR)

    NASA Technical Reports Server (NTRS)

    Mehta, S.; Antich, P.; Blomqvist, C. G. (Principal Investigator)

    1997-01-01

    There exists a growing body of research that relates the measurement of pressure-wave velocity in bone to different physiological conditions and treatment modalities. The shear-wave velocity has been less studied, although it is necessary for a more complete understanding of the mechanical properties of bone. Ultrasound critical-angle reflectometry (UCR) is a noninvasive and nondestructive technique previously used to measure pressure-wave velocities both in vitro and in vivo. This note describes its application to the measurement of shear-wave velocity in bone, whether directly accessible or covered by soft tissue.

  12. GNSS-Reflectometry aboard ISS with GEROS: Investigation of atmospheric propagation effects

    NASA Astrophysics Data System (ADS)

    Zus, F.; Heise, S.; Wickert, J.; Semmling, M.

    2015-12-01

    GEROS-ISS (GNSS rEflectometry Radio Occultation and Scatterometry) is an ESA mission aboard the International Space Station (ISS). The main mission goals are the determination of the sea surface height and surface winds. Secondary goals are monitoring of land surface parameters and atmosphere sounding using GNSS radio occultation measurements. The international scientific study GARCA (GNSS-Reflectometry Assessment of Requirements and Consolidation of Retrieval Algorithms), funded by ESA, is part of the preparations for GEROS-ISS. Major goals of GARCA are the development of an end2end Simulator for the GEROS-ISS measurements (GEROS-SIM) and the evaluation of the error budget of the GNSS reflectometry measurements. In this presentation we introduce some of the GARCA activities to quantify the influence of the ionized and neutral atmosphere on the altimetric measurements, which is a major error source for GEROS-ISS. At first, we analyse, to which extend the standard linear combination of interferometric paths at different carrier frequencies can be used to correct for the ionospheric propagation effects. Second, we make use of the tangent-linear version of our ray-trace algorithm to propagate the uncertainty of the underlying refractivity profile into the uncertainty of the interferometric path. For comparison the sensitivity of the interferometric path with respect to the sea surface height is computed. Though our calculations are based on a number of simplifying assumptions (the Earth is a sphere, the atmosphere is spherically layered and the ISS and GNSS satellite orbits are circular) some general conclusions can be drawn. In essence, for elevation angles above -5° at the ISS the higher-order ionospheric errors and the uncertaintiy of the inteferometric path due to the uncertainty of the underlying refractivity profile are small enough to distinguish a sea surface height of ± 0.5 m.

  13. Frequency domain reflectometry NDE for aging cables in nuclear power plants

    NASA Astrophysics Data System (ADS)

    Glass, S. W.; Jones, A. M.; Fifield, L. S.; Hartman, T. S.

    2017-02-01

    Degradation of the cable jacket, electrical insulation, and other cable components of installed cables within nuclear power plants (NPPs) is known to occur as a function of age, temperature, radiation, and other environmental factors. Although system tests verify cable function under normal loads, demonstration of some cable's ability to perform under exceptional loads associated with design-basis events is essential to assuring plant integrity. The cable's ability to perform safely over the initial 40-year planned and licensed life has generally been demonstrated and there have been very few age-related cable failures. With greater than 1000 km of power, control, instrumentation, and other cables typically found in an NPP, replacing all the cables would be a severe cost burden. Justification for life extension to 60 and 80 years requires a cable aging management program that includes condition monitoring to justify cable performance under normal operation as well as accident conditions. A variety of tests are available to assess various aspects of electrical and mechanical cable performance, but none are suitable for all cable configurations nor does any single test confirm all features of interest. One particularly promising test that is beginning to be used more and more by utilities is frequency domain reflectometry (FDR). FDR is a nondestructive electrical inspection technique used to detect and localize faults in power and communication system conductors along the length of a cable from a single connection point. FDR detects discontinuities in the electrical impedance that arise due to cable splices or similar changes along the path of the conductor pair. In addition, FDR has the potential to provide sensitivity to insulation degradation by detecting small changes in impedance between the cable conductors being examined. The technique is also sensitive to cable bends, the particular lay of the cable in tray, proximity to other cable, and other factors that bear consideration when interpreting the test results. This paper examines various influences on the FDR approach and compares results of three different instruments to assess accelerated aging damage among several NPP representative cables.

  14. Advancements of diffraction-based overlay metrology for double patterning

    NASA Astrophysics Data System (ADS)

    Li, Jie; Kritsun, Oleg; Liu, Yongdong; Dasari, Prasad; Weher, Ulrich; Volkman, Catherine; Mazur, Martin; Hu, Jiangtao

    2011-03-01

    As the dimensions of integrated circuit continue to shrink, diffraction based overlay (DBO) technologies have been developed to address the tighter overlay control challenges. Previously data of high accuracy and high precision were reported for litho-etch-litho-etch double patterning (DP) process using normal incidence spectroscopic reflectometry on specially designed targets composed of 1D gratings in x and y directions. Two measurement methods, empirical algorithm (eDBO) using four pads per direction (2x4 target) and modeling based algorithm (mDBO) using two pads per direction (2x2 target) were performed. In this work, we apply DBO techniques to measure overlay errors for a different DP process, litho-freeze-litho-etch process. We explore the possibility of further reducing number of pads in a DBO target using mDBO. For standard targets composed of 1D gratings, we reported results for eDBO 2x4 targets, mDBO 2x2 targets, and mDBO 2x1 target. The results of all three types of targets are comparable in terms of accuracy, dynamic precision, and TIS. TMU (not including tool matching) is less than 0.1nm. In addition, we investigated the possibility of measuring overlay with one single pad that contains 2D gratings. We achieved good correlation to blossom measurements. TMU (not including tool matching) is ~ 0.2nm. To our best knowledge, this is the first time that DBO results are reported on a single pad. eDBO allows quick recipe setup but takes more space and measurement time. Although mDBO needs details of optical properties and modeling, it offers smaller total target size and much faster throughput, which is important in high volume manufacturing environment.

  15. Performance assessment of the antenna setup for the ITER plasma position reflectometry in-vessel systems.

    PubMed

    Varela, P; Belo, J H; Quental, P B

    2016-11-01

    The design of the in-vessel antennas for the ITER plasma position reflectometry diagnostic is very challenging due to the need to cope both with the space restrictions inside the vacuum vessel and with the high mechanical and thermal loads during ITER operation. Here, we present the work carried out to assess and optimise the design of the antenna. We show that the blanket modules surrounding the antenna strongly modify its characteristics and need to be considered from the early phases of the design. We also show that it is possible to optimise the antenna performance, within the design restrictions.

  16. Design of an Ultra-wide Band Waveguide Transition for the Ex-vessel Transmission Line of ITER Plasma Position Reflectometry

    NASA Astrophysics Data System (ADS)

    Simonetto, A.; Platania, P.; Garavaglia, S.; Gittini, G.; Granucci, G.; Pallotta, F.

    2018-02-01

    Plasma position reflectometry for ITER requires interfaces between in-vessel and ex-vessel waveguides. An ultra broadband interface (15-75 GHz) was designed between moderately oversized rectangular waveguide (20 × 12 mm), operated in TE01 (i.e., tall waveguide mode), and circular corrugated waveguide, with 88.9-mm internal diameter, propagating HE11. The interface was designed both as a sequence of waveguide components and as a quasi-optical confocal telescope. The design and the simulated performance are described for both concepts. The latter one requires more space but has better performance, and shall be prototyped.

  17. Shielded-Twisted-Pair Cable Model for Chafe Fault Detection via Time-Domain Reflectometry

    NASA Technical Reports Server (NTRS)

    Schuet, Stefan R.; Timucin, Dogan A.; Wheeler, Kevin R.

    2012-01-01

    This report details the development, verification, and validation of an innovative physics-based model of electrical signal propagation through shielded-twisted-pair cable, which is commonly found on aircraft and offers an ideal proving ground for detection of small holes in a shield well before catastrophic damage occurs. The accuracy of this model is verified through numerical electromagnetic simulations using a commercially available software tool. The model is shown to be representative of more realistic (analytically intractable) cable configurations as well. A probabilistic framework is developed for validating the model accuracy with reflectometry data obtained from real aircraft-grade cables chafed in the laboratory.

  18. Thermal analysis of the in-vessel components of the ITER plasma-position reflectometry.

    PubMed

    Quental, P B; Policarpo, H; Luís, R; Varela, P

    2016-11-01

    The ITER plasma position reflectometry system measures the edge electron density profile of the plasma, providing real-time supplementary contribution to the magnetic measurements of the plasma-wall distance. Some of the system components will be in direct sight of the plasma and therefore subject to plasma and stray radiation, which may cause excessive temperatures and stresses. In this work, thermal finite element analysis of the antenna and adjacent waveguides is conducted with ANSYS V17 (ANSYS® Academic Research, Release 17.0, 2016). Results allow the identification of critical temperature points, and solutions are proposed to improve the thermal behavior of the system.

  19. In-service communication channel sensing based on reflectometry for TWDM-PON systems

    NASA Astrophysics Data System (ADS)

    Iida, Daisuke; Kuwano, Shigeru; Terada, Jun

    2014-05-01

    Many base stations are accommodated in TWDM-PON based mobile backhaul and fronthaul networks for future radio access, and failed connections in an optical network unit (ONU) wavelength channel severely degrade system performance. A cost effective in-service ONU wavelength channel monitor is essential to ensure proper system operation without failed connections. To address this issue we propose a reflectometry-based remote sensing method that provides wavelength channel information with the optical line terminal (OLT)-ONU distance. The method realizes real-time monitoring of ONU wavelength channels without signal quality degradation. Experimental results show it achieves wavelength channel distinction with high distance resolution.

  20. Grating-assisted polarization optical time-domain reflectometry for distributed fiber-optic sensing.

    PubMed

    Han, Ming; Wang, Yunjing; Wang, Anbo

    2007-07-15

    We report a novel type of polarization optical time-domain reflectometry (POTDR) for fully distributed fiber-optic sensing, in which the reflected optical signal is from a series of fiber Bragg gratings that are uniformly distributed along the fiber. Compared with a conventional POTDR that uses the Rayleigh backscattering, this grating-assisted POTDR can have a much better signal-to-noise ratio and consequently a better measurement resolution and a larger measurement range of the fiber birefringence. Experimental results have shown that the measurement resolution of the grating-assisted POTDR is almost an order of magnitude better than that of a conventional POTDR.

  1. Thermal analysis of the in-vessel components of the ITER plasma-position reflectometry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Quental, P. B., E-mail: pquental@ipfn.tecnico.ulisboa.pt; Policarpo, H.; Luís, R.

    The ITER plasma position reflectometry system measures the edge electron density profile of the plasma, providing real-time supplementary contribution to the magnetic measurements of the plasma-wall distance. Some of the system components will be in direct sight of the plasma and therefore subject to plasma and stray radiation, which may cause excessive temperatures and stresses. In this work, thermal finite element analysis of the antenna and adjacent waveguides is conducted with ANSYS V17 (ANSYS® Academic Research, Release 17.0, 2016). Results allow the identification of critical temperature points, and solutions are proposed to improve the thermal behavior of the system.

  2. Characterization of the Multi-Blade 10B-based detector at the CRISP reflectometer at ISIS for neutron reflectometry at ESS

    NASA Astrophysics Data System (ADS)

    Piscitelli, F.; Mauri, G.; Messi, F.; Anastasopoulos, M.; Arnold, T.; Glavic, A.; Höglund, C.; Ilves, T.; Lopez Higuera, I.; Pazmandi, P.; Raspino, D.; Robinson, L.; Schmidt, S.; Svensson, P.; Varga, D.; Hall-Wilton, R.

    2018-05-01

    The Multi-Blade is a Boron-10-based gaseous thermal neutron detector developed to face the challenge arising in neutron reflectometry at neutron sources. Neutron reflectometers are challenging instruments in terms of instantaneous counting rate and spatial resolution. This detector has been designed according to the requirements given by the reflectometers at the European Spallation Source (ESS) in Sweden. The Multi-Blade has been installed and tested on the CRISP reflectometer at the ISIS neutron and muon source in U.K.. The results on the detailed detector characterization are discussed in this manuscript.

  3. Understanding dynamic changes in live cell adhesion with neutron reflectometry

    PubMed Central

    JUNGHANS, ANN; WALTMAN, MARY JO; SMITH, HILLARY L.; POCIVAVSEK, LUKA; ZEBDA, NOUREDDINE; BIRUKOV, KONSTANTIN; VIAPIANO, MARIANO; MAJEWSKI, JAROSLAW

    2015-01-01

    Neutron reflectometry (NR) was used to examine various live cells adhesion to quartz substrates under different environmental conditions, including flow stress. To the best of our knowledge, these measurements represent the first successful visualization and quantization of the interface between live cells and a substrate with sub-nanometer resolution. In our first experiments, we examined live mouse fibroblast cells as opposed to past experiments using supported lipids, proteins, or peptide layers with no associated cells. We continued the NR studies of cell adhesion by investigating endothelial monolayers and glioblastoma cells under dynamic flow conditions. We demonstrated that neutron reflectometry is a powerful tool to study the strength of cellular layer adhesion in living tissues, which is a key factor in understanding the physiology of cell interactions and conditions leading to abnormal or disease circumstances. Continuative measurements, such as investigating changes in tumor cell – surface contact of various glioblastomas, could impact advancements in tumor treatments. In principle, this can help us to identify changes that correlate with tumor invasiveness. Pursuit of these studies can have significant medical impact on the understanding of complex biological problems and their effective treatment, e.g. for the development of targeted anti-invasive therapies. PMID:25705067

  4. Massive gas insufflation without effect on esophageal reflectometry profiles

    NASA Astrophysics Data System (ADS)

    Raphael, David T.; Arnaudov, Dimiter; Benbassat, Maxim

    2003-10-01

    Time-domain acoustic reflectometry generates a ``one-dimensional'' image of the interior of a cavity in the form of an area-distance profile. After patient intubation with a breathing tube, the characteristic reflectometry profile consists of a constant-area segment corresponding to the length of the tube, followed either by a rapid increase in the area beyond the carina (lung) or by a sudden decrease in the area to zero (esophagus). In the cardiac arrest setting, during mistaken placement of the breathing tube into the esophagus, followed by aggressive manual ventilation, is it possible to markedly distend the esophagus, such that the esophageal profile looks like a tracheal profile? With approval of the USC IUCAC Committee, an animal study was conducted with anesthetized, tracheally intubated, and mechanically ventilated dogs. With a separate breathing tube in the esophagus, aggressive esophageal ventilation (comparable to that seen in the cardiopulmonary resuscitation setting) was accomplished with a manual resuscitation bag. A Benson Hood Labs two-microphone reflectometer was used to obtain esophageal profiles with and without the above ventilation. In this pilot study, there was no significant esophageal distention as a result of the above ventilation. [Research supported by the Alfred E. Mann Institute.

  5. Correspondence between retinal reflectometry and a flicker-based technique in the measurement of macular pigment spatial profiles

    NASA Astrophysics Data System (ADS)

    van der Veen, Rob L. P.; Berendschot, Tos T. J. M.; Makridaki, Maria; Hendrikse, Fred; Carden, David; Murray, Ian J.

    2009-11-01

    A comparison of macular pigment optical density (MPOD) spatial profiles determined by an optical and a psychophysical technique is presented. We measured the right eyes of 19 healthy individuals, using fundus reflectometry at 0, 1, 2, 4, 6, and 8 deg eccentricity; and heterochromatic flicker photometry (HFP) at 0, 0.5, 1, 2, 3, 4, 5, 6, and 7 deg, and a reference point at 8 deg eccentricity. We found a strong correlation between the two techniques. However, the absolute estimates obtained by fundus reflectometry data were higher than by HFP. These differences could partly be explained by the fact that at 8 deg eccentricity the MPOD is not zero, as assumed in HFP. Furthermore, when performing HFP for eccentricities of <1 deg, we had to assume that subjects set flicker thresholds at 0.4 deg horizontal translation when using a 1-deg stimulus. MPOD profiles are very similar for both techniques if, on average, 0.05 DU is added to the HFP data at all eccentricities. An additional correction factor, dependent on the steepness of the MPOD spatial distribution, is required for 0 deg.

  6. Low-noise heterodyne receiver for electron cyclotron emission imaging and microwave imaging reflectometry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tobias, B., E-mail: bjtobias@pppl.gov; Domier, C. W.; Luhmann, N. C.

    2016-11-15

    The critical component enabling electron cyclotron emission imaging (ECEI) and microwave imaging reflectometry (MIR) to resolve 2D and 3D electron temperature and density perturbations is the heterodyne imaging array that collects and downconverts radiated emission and/or reflected signals (50–150 GHz) to an intermediate frequency (IF) band (e.g. 0.1–18 GHz) that can be transmitted by a shielded coaxial cable for further filtering and detection. New circuitry has been developed for this task, integrating gallium arsenide (GaAs) monolithic microwave integrated circuits (MMICs) mounted on a liquid crystal polymer (LCP) substrate. The improved topology significantly increases electromagnetic shielding from out-of-band interference, leads tomore » 10× improvement in the signal-to-noise ratio, and dramatic cost savings through integration. The current design, optimized for reflectometry and edge radiometry on mid-sized tokamaks, has demonstrated >20 dB conversion gain in upper V-band (60-75 GHz). Implementation of the circuit in a multi-channel electron cyclotron emission imaging (ECEI) array will improve the diagnosis of edge-localized modes and fluctuations of the high-confinement, or H-mode, pedestal.« less

  7. Low-noise heterodyne receiver for electron cyclotron emission imaging and microwave imaging reflectometry

    DOE PAGES

    Tobias, B.; Domier, C. W.; Luhmann, Jr., N. C.; ...

    2016-07-25

    The critical component enabling electron cyclotron emission imaging (ECEI) and microwave imaging reflectometry (MIR) to resolve 2D and 3D electron temperature and density perturbations is the heterodyne imaging array that collects and downconverts radiated emission and/or reflected signals (50-150 GHz) to an intermediate frequency (IF) band (e.g. 0.1-18 GHz) that can be transmitted by a shielded coaxial cable for further filtering and detection. New circuitry has been developed for this task, integrating gallium arsenide (GaAs) monolithic microwave integrated circuits (MMICs) mounted on a liquid crystal polymer (LCP) substrate. The improved topology significantly increases electromagnetic shielding from out-of-band interference, leads tomore » 10x improvement in the signal-to-noise ratio, and dramatic cost savings through integration. The current design, optimized for reflectometry and edge radiometry on mid-sized tokamaks, has demonstrated >20 dB conversion gain in upper V-band (60-75 GHz). As a result, implementation of the circuit in a multi-channel electron cyclotron emission imaging (ECEI) array will improve the diagnosis of edge-localized modes and fluctuations of the high-confinement, or H-mode, pedestal.« less

  8. Secondary electron emission from electrically charged fluorinated-ethylene-propylene Teflon for normal and non-normal electron incidence. M.S. Thesis; [spacecraft thermal coatings

    NASA Technical Reports Server (NTRS)

    Budd, P. A.

    1981-01-01

    The secondary electron emission coefficient was measured for a charged polymer (FEP-Teflon) with normally and obliquely incident primary electrons. Theories of secondary emission are reviewed and the experimental data is compared to these theories. Results were obtained for angles of incidence up to 60 deg in normal electric fields of 1500 V/mm. Additional measurements in the range from 50 to 70 deg were made in regions where the normal and tangential fields were approximately equal. The initial input angles and measured output point of the electron beam could be analyzed with computer simulations in order to determine the field within the chamber. When the field is known, the trajectories can be calculated for impacting electrons having various energies and angles of incidence. There was close agreement between the experimental results and the commonly assumed theoretical model in the presence of normal electric fields for angles of incidence up to 60 deg. High angle results obtained in the presence of tangential electric fields did not agree with the theoretical models.

  9. Measuring Ocean Surface Waves using Signal Reflections from Geostationary Satellites

    NASA Astrophysics Data System (ADS)

    Ouellette, J. D.; Dowgiallo, D. J.; Hwang, P. A.; Toporkov, J. V.

    2017-12-01

    The delay-Doppler response of communications signals (such as GNSS) reflected off the ocean surface is well-known to have properties which strongly correlate with surface wind conditions and ocean surface roughness. This study extends reflectometry techniques currently applied to the GNSS constellation to include geostationary communications satellites such as XM Radio. In this study, ocean wind conditions and significant wave height will be characterized using the delay-Doppler response of XM Radio signals reflected off of ocean surface waves. Using geostationary satellites for reflectometry-based remote sensing of oceans presents two primary advantages. First, longer coherent integration times can be achieved, which boosts signal processing gain and allows for finer Doppler resolution. Second, being designed for wide-area broadcast communications, the ground-received power of these geostationary satellite signals tends to be many orders of magnitude stronger than e.g. GNSS signals. Reflections of such signals from the ocean are strong enough to be received well outside of the specular region. This flexibility of viewing geometry allows signal processing to be performed on data received from multiple incidence/reception angles, which can provide a more complete characterization of ocean surface roughness and surface wind vectors. This work will include studies of simulated and measured delay-Doppler behavior of XM Radio signals reflected from dynamic ocean surfaces. Simulation studies will include inter-comparison between a number of hydrodynamic and electromagnetic models. Results from simulations will be presented as delay-Doppler plots and will be compared with delay-Doppler behavior observed in measured data. Measured data will include field campaign results from early- to mid-2017 in which the US Naval Research Laboratory's in-house XM reflectometer-receiver was deployed near the coasts of Virginia and North Carolina to observe reflections from wind-driven ocean waves. Preliminary results from a significant wave height retrieval algorithm will also be presented.

  10. A new generation of x-ray spectrometry UHV instruments at the SR facilities BESSY II, ELETTRA and SOLEIL

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lubeck, J., E-mail: janin.lubeck@ptb.de; Fliegauf, R.; Holfelder, I.

    A novel type of ultra-high vacuum instrument for X-ray reflectometry and spectrometry-related techniques for nanoanalytics by means of synchrotron radiation (SR) has been constructed and commissioned at BESSY II. This versa-tile instrument was developed by the PTB, Germany’s national metrology institute, and includes a 9-axis manipulator that allows for an independent alignment of the samples with respect to all degrees of freedom. In addition, it integrates a rotational and translational movement of several photodiodes as well as a translational movement of a beam-geometry-defining aperture system. Thus, the new instrument enables various analytical techniques based on energy dispersive X-ray detectors suchmore » as reference-free X-Ray Fluorescence (XRF) analysis, total-reflection XRF, grazing-incidence XRF, in addition to optional X-Ray Reflectometry (XRR) measurements or polarization-dependent X-ray absorption fine structure analyses (XAFS). Samples having a size of up to (100 × 100) mm{sup 2}; can be analyzed with respect to their mass deposition, elemental, spatial or species composition. Surface contamination, nanolayer composition and thickness, depth pro-file of matrix elements or implants, nanoparticles or buried interfaces as well as molecular orientation of bonds can be accessed. Three technology transfer projects of adapted instruments have enhanced X-Ray Spectrometry (XRS) research activities within Europe at the synchrotron radiation facilities ELETTRA (IAEA) and SOLEIL (CEA/LNE-LNHB) as well as at the X-ray innovation laboratory BLiX (TU Berlin) where different laboratory sources are used. Here, smaller chamber requirements led PTB in cooperation with TU Berlin to develop a modified instrument equipped with a 7-axis manipulator: reduced freedom in the choice of experimental geometry modifications (absence of out-of-SR-plane and reference-free XRS options) has been compensated by encoder-enhanced angular accuracy for GIXRF and XRR.« less

  11. Detection and characterization of corrosion of bridge cables by time domain reflectometry

    NASA Astrophysics Data System (ADS)

    Liu, Wei; Hunsperger, Robert G.; Folliard, Kevin; Chajes, Michael J.; Barot, Jignesh; Jhaveri, Darshan; Kunz, Eric

    1999-02-01

    In this paper, we develop and demonstrate a nondestructive evaluation technique for corrosion detection of embedded or encased steel cables. This technique utilizes time domain reflectometry (TDR), which has been traditionally used to detect electrical discontinuities in transmission lines. By applying a sensor wire along with the bridge cable, we can model the cable as an asymmetric, twin-conductor transmission line. Physical defects of the bridge cable will change the electromagnetic properties of the line and can be detected by TDR. Furthermore, different types of defects can be modeled analytically, and identified using TDR. TDR measurement results from several fabricated bridge cable sections with built-in defects are reported.

  12. Magnetic Nonuniformity and Thermal Hysteresis of Magnetism in a Manganite Thin Film [Depth profiling of magnetization and coupling of strain with magnetization in (La 0.4Pr 0.6) 0.67Ca 0.33MnO 3 films

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Singh, Surendra; Fitzsimmons, M. R.; Lookman, T.

    We measured the chemical and magnetic depth profiles of a single crystalline film grown on a NdGaO 3 substrate using x-ray reflectometry, electron microscopy, electron energy-loss spectroscopy and polarized neutron reflectometry. Our data indicate that the film exhibits coexistence of different magnetic phases as a function of depth. The magnetic depth profile is correlated with a variation of chemical composition with depth. The thermal hysteresis of ferromagnetic order in the film suggests a first order ferromagnetic transition at low temperatures

  13. Magnetic nonuniformity and thermal hysteresis of magnetism in a manganite thin film.

    PubMed

    Singh, Surendra; Fitzsimmons, M R; Lookman, T; Thompson, J D; Jeen, H; Biswas, A; Roldan, M A; Varela, M

    2012-02-17

    We measured the chemical and magnetic depth profiles of a single crystalline (La(1-x)Pr(x))(1-y)Ca(y)MnO(3-δ) (x=0.52±0.05, y=0.23±0.04, δ=0.14±0.10) film grown on a NdGaO(3) substrate using x-ray reflectometry, electron microscopy, electron energy-loss spectroscopy, and polarized neutron reflectometry. Our data indicate that the film exhibits coexistence of different magnetic phases as a function of depth. The magnetic depth profile is correlated with a variation of chemical composition with depth. The thermal hysteresis of ferromagnetic order in the film suggests a first-order ferromagnetic transition at low temperatures.

  14. Balanced PIN-TIA photoreceiver with integrated 3 dB fiber coupler for distributed fiber optic sensors

    NASA Astrophysics Data System (ADS)

    Datta, Shubhashish; Rajagopalan, Sruti; Lemke, Shaun; Joshi, Abhay

    2014-06-01

    We report a balanced PIN-TIA photoreceiver integrated with a 3 dB fiber coupler for distributed fiber optic sensors. This detector demonstrates -3 dB bandwidth >15 GHz and coupled conversion gain >65 V/W per photodiode through either input port of the 3 dB coupler, and can be operated at local oscillator power of +17 dBm. The combined common mode rejection of the balanced photoreceiver and the integrated 3 dB coupler is >20 dB. We also present measurement results with various optical stimuli, namely impulses, sinusoids, and pseudo-random sequences, which are relevant for time domain reflectometry, frequency domain reflectometry, and code correlation sensors, respectively.

  15. Spectral emissivity and transmissivity measurement for zinc sulphide infrared window based on integrating-sphere reflectometry

    NASA Astrophysics Data System (ADS)

    Zhang, Yu-Feng; Dai, Jing-Min; Zhang, Lei; Pan, Wei-Dong

    2013-08-01

    The spectral emissivity and transmissivity of zinc sulphide (ZnS) infrared windows in the spectral region from 2 to 12 μm and temperature range from 20 to 700°C is measured by a facility built at the Harbin Institute of Technology (HIT). The facility is based on the integrating-sphere reflectometry. Measurements have been performed on two samples made of ZnS. The results measured at 20°C are in good agreement with those obtained by the method of radiant energy comparison using a Fourier transform infrared spectrometer. Emissivity measurements performed with this facility present an uncertainty of 5.5% (cover factor=2).

  16. Distributed fiber optical sensing of oxygen with optical time domain reflectometry.

    PubMed

    Eich, Susanne; Schmälzlin, Elmar; Löhmannsröben, Hans-Gerd

    2013-05-31

    In many biological and environmental applications spatially resolved sensing of molecular oxygen is desirable. A powerful tool for distributed measurements is optical time domain reflectometry (OTDR) which is often used in the field of telecommunications. We combine this technique with a novel optical oxygen sensor dye, triangular-[4] phenylene (TP), immobilized in a polymer matrix. The TP luminescence decay time is 86 ns. The short decay time of the sensor dye is suitable to achieve a spatial resolution of some meters. In this paper we present the development and characterization of a reflectometer in the UV range of the electromagnetic spectrum as well as optical oxygen sensing with different fiber arrangements.

  17. Distributed Fiber Optical Sensing of Oxygen with Optical Time Domain Reflectometry

    PubMed Central

    Eich, Susanne; Schmälzlin, Elmar; Löhmannsröben, Hans-Gerd

    2013-01-01

    In many biological and environmental applications spatially resolved sensing of molecular oxygen is desirable. A powerful tool for distributed measurements is optical time domain reflectometry (OTDR) which is often used in the field of telecommunications. We combine this technique with a novel optical oxygen sensor dye, triangular-[4] phenylene (TP), immobilized in a polymer matrix. The TP luminescence decay time is 86 ns. The short decay time of the sensor dye is suitable to achieve a spatial resolution of some meters. In this paper we present the development and characterization of a reflectometer in the UV range of the electromagnetic spectrum as well as optical oxygen sensing with different fiber arrangements. PMID:23727953

  18. Birefringence insensitive optical coherence domain reflectometry system

    DOEpatents

    Everett, Matthew J.; Davis, Joseph G.

    2002-01-01

    A birefringence insensitive fiber optic optical coherence domain reflectometry (OCDR) system is provided containing non-polarization maintaining (non-PM) fiber in the sample arm and the reference arm without suffering from signal degradation caused by birefringence. The use of non-PM fiber significantly reduces the cost of the OCDR system and provides a disposable or multiplexed section of the sample arm. The dispersion in the reference arm and sample arm of the OCDR system are matched to achieve high resolution imaging. This system is useful in medical applications or for non-medical in situ probes. The disposable section of non-PM fiber in the sample arm can be conveniently replaced when contaminated by a sample or a patient.

  19. Polarized Neutron Reflectometry of Nickel Corrosion Inhibitors.

    PubMed

    Wood, Mary H; Welbourn, Rebecca J L; Zarbakhsh, Ali; Gutfreund, Philipp; Clarke, Stuart M

    2015-06-30

    Polarized neutron reflectometry has been used to investigate the detailed adsorption behavior and corrosion inhibition mechanism of two surfactants on a nickel surface under acidic conditions. Both the corrosion of the nickel surface and the structure of the adsorbed surfactant layer could be monitored in situ by the use of different solvent contrasts. Layer thicknesses and roughnesses were evaluated over a range of pH values, showing distinctly the superior corrosion inhibition of one negatively charged surfactant (sodium dodecyl sulfate) compared to a positively charged example (dodecyl trimethylammonium bromide) due to its stronger binding interaction with the surface. It was found that adequate corrosion inhibition occurs at significantly less than full surface coverage.

  20. Normal-incidence quantum cascade detector coupled by nanopore structure

    NASA Astrophysics Data System (ADS)

    Liu, Jianqi; Wang, Fengjiao; Zhai, Shenqiang; Zhang, Jinchuan; Liu, Shuman; Liu, Junqi; Wang, Lijun; Liu, Fengqi; Wang, Zhanguo

    2018-04-01

    A normal-incidence quantum cascade detector coupled by a nanopore array structure (NPS) is demonstrated. The NPS is fabricated on top of an In0.53Ga0.47As contact layer by inductively coupled plasma etching using anodic aluminum oxide as a mask. Because of the nonuniform volume fraction at different areas of the device mesa, the NPS acts as subwavelength random gratings. Normal-incidence light can be scattered into random oblique directions for inter-sub-band transition absorption. With normal incidence, the responsivities of the device reach 24 mA/W at 77 K and 15.7 mA/W at 300 K, which are enhanced 2.23 and 1.96 times, respectively, compared with that of the 45°-edge device.

  1. X-ray reflectometry and simulation of the parameters of SiC epitaxial films on Si(111), grown by the atomic substitution method

    NASA Astrophysics Data System (ADS)

    Kukushkin, S. A.; Nussupov, K. Kh.; Osipov, A. V.; Beisenkhanov, N. B.; Bakranova, D. I.

    2017-05-01

    The structure and composition of SiC nanolayers are comprehensively studied by X-ray reflectometry, IR-spectroscopy, and atomic-force microscopy (AFM) methods for the first time. SiC films were synthesized by the new method of topochemical substitution of substrate atoms at various temperatures and pressure of CO active gas on the surface of high-resistivity low-dislocation single-crystal n-type silicon (111). Based on an analysis and generalization of experimental data obtained using X-ray reflectometry, IR spectroscopy, and AFM methods, a structural model of SiC films on Si was proposed. According to this model, silicon carbide film consists of a number of layers parallel to the substrate, reminiscent of a layer cake. The composition and thickness of each layer entering the film structure is experimentally determined. It was found that all samples contain superstoichiometric carbon; however, its structure is significantly different for the samples synthesized at temperatures of 1250 and 1330°C, respectively. In the former case, the film surface is saturated with silicon vacancies and carbon in the structurally loose form reminiscent of HOPG carbon. In the films grown at 1330°C, carbon is in a dense structure with a close-to-diamond density.

  2. Understanding dynamic changes in live cell adhesion with neutron reflectometry

    DOE PAGES

    Junghans, Ann; Waltman, Mary Jo; Smith, Hillary L.; ...

    2014-12-10

    In this study, neutron reflectometry (NR) was used to examine various live cells' adhesion to quartz substrates under different environmental conditions, including flow stress. To the best of our knowledge, these measurements represent the first successful visualization and quantization of the interface between live cells and a substrate with sub-nanometer resolution. In our first experiments, we examined live mouse fibroblast cells as opposed to past experiments using supported lipids, proteins, or peptide layers with no associated cells. We continued the NR studies of cell adhesion by investigating endothelial monolayers and glioblastoma cells under dynamic flow conditions. We demonstrated that neutronmore » reflectometry is a powerful tool to study the strength of cellular layer adhesion in living tissues, which is a key factor in understanding the physiology of cell interactions and conditions leading to abnormal or disease circumstances. Continuative measurements, such as investigating changes in tumor cell — surface contact of various glioblastomas, could impact advancements in tumor treatments. In principle, this can help us to identify changes that correlate with tumor invasiveness. Pursuit of these studies can have significant medical impact on the understanding of complex biological problems and their effective treatment, e.g. for the development of targeted anti-invasive therapies.« less

  3. Optimization of the method for assessment of brain perfusion in humans using contrast-enhanced reflectometry: multidistance time-resolved measurements

    NASA Astrophysics Data System (ADS)

    Milej, Daniel; Janusek, Dariusz; Gerega, Anna; Wojtkiewicz, Stanislaw; Sawosz, Piotr; Treszczanowicz, Joanna; Weigl, Wojciech; Liebert, Adam

    2015-10-01

    The aim of the study was to determine optimal measurement conditions for assessment of brain perfusion with the use of optical contrast agent and time-resolved diffuse reflectometry in the near-infrared wavelength range. The source-detector separation at which the distribution of time of flights (DTOF) of photons provided useful information on the inflow of the contrast agent to the intracerebral brain tissue compartments was determined. Series of Monte Carlo simulations was performed in which the inflow and washout of the dye in extra- and intracerebral tissue compartments was modeled and the DTOFs were obtained at different source-detector separations. Furthermore, tests on diffuse phantoms were carried out using a time-resolved setup allowing the measurement of DTOFs at 16 source-detector separations. Finally, the setup was applied in experiments carried out on the heads of adult volunteers during intravenous injection of indocyanine green. Analysis of statistical moments of the measured DTOFs showed that the source-detector separation of 6 cm is recommended for monitoring of inflow of optical contrast to the intracerebral brain tissue compartments with the use of continuous wave reflectometry, whereas the separation of 4 cm is enough when the higher-order moments of DTOFs are available.

  4. Analysis of bacterial growth by UV/Vis spectroscopy and laser reflectometry

    NASA Astrophysics Data System (ADS)

    Peña-Gomar, Mary Carmen; Viramontes-Gamboa, Gonzalo; Peña-Gomar, Grethel; Ortiz Gutiérrez, Mauricio; Hernández Ramírez, Mariano

    2012-10-01

    This work presents a preliminary study on an experimental analysis of the lactobacillus bacterial growth in liquid medium with and without the presence of silver nanoparticles. The study aims to quantify the bactericidal effect of nanoparticles. Quantification of bacterial growth at different times was analyzed by spectroscopy UV/visible and laser reflectometry near the critical angle. From these two techniques the best results were obtained by spectroscopy, showing that as the concentration of silver nanoparticles increases, it inhibits the growth of bacteria, it only grows 63% of the population. Regarding Laser Reflectometry, the variation of reflectance near the critical angle is measured in real time. The observed results at short times are reasonable, since they indicate a gradual growth of the bacteria and the stabilization stage of the population. But at long time, the observed results show abrupt changes caused by temperature effects. The bacteria were isolated from samples taken from commercial yougurth, and cultured in MRS broth at pH 6.5, and controlled with citric acid and constant temperature of 32 °C. Separately, silver nanoparticles were synthesized at 3 °C from aqueous solutions of 1.0 mM silver nitrate and chemically reduced with sodium borohydride to 2.0 mM, with magnetic stirring.

  5. Neutron reflectometry on highly absorbing films and its application to 10B4C-based neutron detectors

    PubMed Central

    Piscitelli, F.; Khaplanov, A.; Devishvili, A.; Schmidt, S.; Höglund, C.; Birch, J.; Dennison, A. J. C.; Gutfreund, P.; Hall-Wilton, R.; Van Esch, P.

    2016-01-01

    Neutron reflectometry is a powerful tool used for studies of surfaces and interfaces. The absorption in the typical studied materials is neglected and this technique is limited only to the reflectivity measurement. For strongly absorbing nuclei, the absorption can be directly measured by using the neutron-induced fluorescence technique which exploits the prompt particle emission of absorbing isotopes. This technique is emerging from soft matter and biology where highly absorbing nuclei, in very small quantities, are used as a label for buried layers. Nowadays, the importance of absorbing layers is rapidly increasing, partially because of their application in neutron detection; a field that has become more active also due to the 3He-shortage. We extend the neutron-induced fluorescence technique to the study of layers of highly absorbing materials, in particular 10B4C. The theory of neutron reflectometry is a commonly studied topic; however, when a strong absorption is present the subtle relationship between the reflection and the absorption of neutrons is not widely known. The theory for a general stack of absorbing layers has been developed and compared to measurements. We also report on the requirements that a 10B4C layer must fulfil in order to be employed as a converter in neutron detection. PMID:26997902

  6. Deuterium Labeling Strategies for Creating Contrast in Structure-Function Studies of Model Bacterial Outer Membranes Using Neutron Reflectometry.

    PubMed

    Le Brun, Anton P; Clifton, Luke A; Holt, Stephen A; Holden, Peter J; Lakey, Jeremy H

    2016-01-01

    Studying the outer membrane of Gram-negative bacteria is challenging due to the complex nature of its structure. Therefore, simplified models are required to undertake structure-function studies of processes that occur at the outer membrane/fluid interface. Model membranes can be created by immobilizing bilayers to solid supports such as gold or silicon surfaces, or as monolayers on a liquid support where the surface pressure and fluidity of the lipids can be controlled. Both model systems are amenable to having their structure probed by neutron reflectometry, a technique that provides a one-dimensional depth profile through a membrane detailing its thickness and composition. One of the strengths of neutron scattering is the ability to use contrast matching, allowing molecules containing hydrogen and those enriched with deuterium to be highlighted or matched out against the bulk isotopic composition of the solvent. Lipopolysaccharides, a major component of the outer membrane, can be isolated for incorporation into model membranes. Here, we describe the deuteration of lipopolysaccharides from rough strains of Escherichia coli for incorporation into model outer membranes, and how the use of deuterated materials enhances structural analysis of model membranes by neutron reflectometry. © 2016 Elsevier Inc. All rights reserved.

  7. Signals of Opportunity Earth Reflectometry (SoOp-ER): Enabling new microwave observations from small satellites

    NASA Astrophysics Data System (ADS)

    Garrison, J. L.; Piepmeier, J. R.; Shah, R.; Lin, Y. C.; Du Toit, C. F.; Vega, M. A.; Knuble, J. J.

    2016-12-01

    Several recent experiments have demonstrated remote sensing by reutilizing communication satellite transmissions as sources in a bistatic radar configuration. This technique, referred to as "Signals of Opportunity Earth Reflectometry" (SoOp-ER), combines aspects of passive radiometry, active scatterometry and radar altimetry, but is essentially a new and alternative approach to microwave remote sensing. Reflectometry was first demonstrated with Global Navigation Satellite System (GNSS) signals, enabled by their use of pseudorandom noise (PRN) codes for ranging. Two decades of research in GNSS reflectometry has culminated in the upcoming launches of several satellite missions within the next few years (TechDemoSat-1, CYGNSS, and GEROS-ISS). GNSS signals, however, have low power and are confined to a few L-band frequencies allocated to radionavigation. Communication satellites, in contrast, transmit in nearly all bands penetrating the Earth's atmosphere at very high radiated powers to assure a low bit-error-rate. High transmission power and a forward scatter geometry result in a very high signal to noise ratio at the receiver. Surface resolution is determined by the signal bandwidth, not the antenna beam. In many applications, this will allow small, low gain antennas to be used to make scientifically useful measurements. These features indicate that SoOp-ER instruments would be an ideal technology for microwave remote sensing from small platforms. SoOp-ER observations are referenced at the specular point and a constellation of small satellites, evenly spaced in the same orbit, would provide global coverage through parallel specular point ground tracks. This presentation will summarize the current instrument development work by the authors on three different application of SoOp-ER: P-band (230-270 MHz) sensing of root-zone soil moisture (RZSM), S-band sensing of ocean winds and Ku/Ka-band altimetry. Potential mission scenarios using small satellite constellations using SoOp-ER at these frequencies are under study.

  8. Design of a normal incidence multilayer imaging X-ray microscope

    NASA Astrophysics Data System (ADS)

    Shealy, David L.; Gabardi, David R.; Hoover, Richard B.; Walker, Arthur B. C., Jr.; Lindblom, Joakim F.

    Normal incidence multilayer Cassegrain X-ray telescopes were flown on the Stanford/MSFC Rocket X-ray Spectroheliograph. These instruments produced high spatial resolution images of the sun and conclusively demonstrated that doubly reflecting multilayer X-ray optical systems are feasible. The images indicated that aplanatic imaging soft X-ray/EUV microscopes should be achievable using multilayer optics technology. A doubly reflecting normal incidence multilayer imaging X-ray microscope based on the Schwarzschild configuration has been designed. The design of the microscope and the results of the optical system ray trace analysis are discussed. High resolution aplanatic imaging X-ray microscopes using normal incidence multilayer X-ray mirrors should have many important applications in advanced X-ray astronomical instrumentation, X-ray lithography, biological, biomedical, metallurgical, and laser fusion research.

  9. Real-time reflectometry measurement validation in H-mode regimes for plasma position control.

    PubMed

    Santos, J; Guimarais, L; Manso, M

    2010-10-01

    It has been shown that in H-mode regimes, reflectometry electron density profiles and an estimate for the density at the separatrix can be jointly used to track the separatrix within the precision required for plasma position control on ITER. We present a method to automatically remove, from the position estimation procedure, measurements performed during collapse and recovery phases of edge localized modes (ELMs). Based on the rejection mechanism, the method also produces an estimate confidence value to be fed to the position feedback controller. Preliminary results show that the method improves the real-time experimental separatrix tracking capabilities and has the potential to eliminate the need for an external online source of ELM event signaling during control feedback operation.

  10. Formation of He-Rich Layers Observed by Neutron Reflectometry in the He-Ion-Irradiated Cr/W Multilayers: Effects of Cr/W Interfaces on the He-Trapping Behavior.

    PubMed

    Chen, Feida; Tang, Xiaobin; Huang, Hai; Li, Xinxi; Wang, Yan; Huang, Chaoqiang; Liu, Jian; Li, Huan; Chen, Da

    2016-09-21

    Cr/W multilayer nanocomposites were presented in the paper as potential candidate materials for the plasma facing components in fusion reactors. We used neutron reflectometry to measure the depth profile of helium in the multienergy He ions irradiated [Cr/W (50 nm)]3 multilayers. Results showed that He-rich layers with low neutron scattering potential energy form at the Cr/W interfaces, which is in great agreement with previous modeling results of other multilayers. This phenomenon provided a strong evidence for the He trapping effects of Cr/W interfaces and implied the possibility of using the Cr/W multilayer nanocomposites as great He-tolerant plasma facing materials.

  11. Distributed strain measurement and possible breakage detection of optical-fiber-embedded composite structure using slope-assisted Brillouin optical correlation-domain reflectometry

    NASA Astrophysics Data System (ADS)

    Lee, Heeyoung; Ochi, Yutaka; Matsui, Takahiro; Matsumoto, Yukihiro; Tanaka, Yosuke; Nakamura, Hitoshi; Mizuno, Yosuke; Nakamura, Kentaro

    2018-07-01

    Slope-assisted Brillouin optical correlation-domain reflectometry (SA-BOCDR) is a recently developed structural health monitoring technique for measurements of strain, temperature, and loss distributions along optical fibers. Although the basic operational principle of this method has been clarified, no measurements using optical fibers embedded in actual structures have been reported. As a first step towards such practical applications, in this study, we present an example of an SA-BOCDR-based diagnosis using a composite structure with carbon fiber-reinforced plastics. The system’s output agrees well with the actual strain distributions. We were also able to detect the breakage of the embedded fiber, thus demonstrating the promise of SA-BOCDR for practical applications.

  12. Development of 3D microwave imaging reflectometry in LHD (invited).

    PubMed

    Nagayama, Y; Kuwahara, D; Yoshinaga, T; Hamada, Y; Kogi, Y; Mase, A; Tsuchiya, H; Tsuji-Iio, S; Yamaguchi, S

    2012-10-01

    Three-dimensional (3D) microwave imaging reflectometry has been developed in the large helical device to visualize fluctuating reflection surface which is caused by the density fluctuations. The plasma is illuminated by the probe wave with four frequencies, which correspond to four radial positions. The imaging optics makes the image of cut-off surface onto the 2D (7 × 7 channels) horn antenna mixer arrays. Multi-channel receivers have been also developed using micro-strip-line technology to handle many channels at reasonable cost. This system is first applied to observe the edge harmonic oscillation (EHO), which is an MHD mode with many harmonics that appears in the edge plasma. A narrow structure along field lines is observed during EHO.

  13. Development of 3D microwave imaging reflectometry in LHD (invited)a)

    NASA Astrophysics Data System (ADS)

    Nagayama, Y.; Kuwahara, D.; Yoshinaga, T.; Hamada, Y.; Kogi, Y.; Mase, A.; Tsuchiya, H.; Tsuji-Iio, S.; Yamaguchi, S.

    2012-10-01

    Three-dimensional (3D) microwave imaging reflectometry has been developed in the large helical device to visualize fluctuating reflection surface which is caused by the density fluctuations. The plasma is illuminated by the probe wave with four frequencies, which correspond to four radial positions. The imaging optics makes the image of cut-off surface onto the 2D (7 × 7 channels) horn antenna mixer arrays. Multi-channel receivers have been also developed using micro-strip-line technology to handle many channels at reasonable cost. This system is first applied to observe the edge harmonic oscillation (EHO), which is an MHD mode with many harmonics that appears in the edge plasma. A narrow structure along field lines is observed during EHO.

  14. Detection of 2-mm-long strained section in silica fiber using slope-assisted Brillouin optical correlation-domain reflectometry

    NASA Astrophysics Data System (ADS)

    Lee, Heeyoung; Mizuno, Yosuke; Nakamura, Kentaro

    2018-02-01

    Slope-assisted Brillouin optical correlation-domain reflectometry is a single-end-access distributed Brillouin sensing technique with high spatial resolution and high-speed operation. We have recently discovered its unique feature, that is, strained or heated sections even shorter than nominal resolution can be detected, but its detailed characterization has not been carried out. Here, after experimentally characterizing this “beyond-nominal-resolution” effect, we show its usefulness by demonstrating the detection of a 2-mm-long strained section along a silica fiber. We also demonstrate the detection of a 5-mm-long heated section along a polymer optical fiber. The lengths of these detected sections are smaller than those of the other demonstrations reported so far.

  15. Retrieval of phase information in neutron reflectometry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    de Haan, V.; van Well, A.A.; Adenwalla, S.

    Neutron reflectometry can determine unambiguously the chemical depth profile of a thin film if both phase and amplitude of the reflectance are known. The recovery of the phase information is achieved by adding to the unknown layered structure a known ferromagnetic layer. The ferromagnetic layer is magnetized by an external magnetic field in a direction lying in the plane of the layer and subsequently perpendicular to it. The neutrons are polarized either parallel or opposite to the magnetic field. In this way three measurements can be made, with different (and known) scattering-length densities of the ferromagnetic layer. The reflectivity obtainedmore » from each measurement can be represented by a circle in the (complex) reflectance plane. The intersections of these circles provide the reflectance.« less

  16. Serum potassium is a predictor of incident diabetes in African Americans with normal aldosterone: the Jackson Heart Study12

    PubMed Central

    Chatterjee, Ranee; Davenport, Clemontina A; Svetkey, Laura P; Batch, Bryan C; Lin, Pao-Hwa; Ramachandran, Vasan S; Fox, Ervin R; Harman, Jane; Yeh, Hsin-Chieh; Selvin, Elizabeth; Correa, Adolfo; Butler, Kenneth; Edelman, David

    2017-01-01

    Background: Low-normal potassium is a risk factor for diabetes and may account for some of the racial disparity in diabetes risk. Aldosterone affects serum potassium and is associated with insulin resistance. Objectives: We sought to confirm the association between potassium and incident diabetes in an African-American cohort, and to determine the effect of aldosterone on this association. Design: We studied participants from the Jackson Heart Study, an African-American adult cohort, who were without diabetes at baseline. With the use of logistic regression, we characterized the associations of serum, dietary, and urinary potassium with incident diabetes. In addition, we evaluated aldosterone as a potential effect modifier of these associations. Results: Of 2157 participants, 398 developed diabetes over 8 y. In a minimally adjusted model, serum potassium was a significant predictor of incident diabetes (OR: 0.83; 95% CI: 0.74, 0.92 per SD increment in serum potassium). In multivariable models, we found a significant interaction between serum potassium and aldosterone (P = 0.046). In stratified multivariable models, in those with normal aldosterone (<9 ng/dL, n = 1163), participants in the highest 2 potassium quartiles had significantly lower odds of incident diabetes than did those in the lowest potassium quartile [OR (95% CI): 0.61 (0.39, 0.97) and 0.54 (0.33, 0.90), respectively]. Among those with high-normal aldosterone (≥9 ng/dL, n = 202), we found no significant association between serum potassium and incident diabetes. In these stratified models, serum aldosterone was not a significant predictor of incident diabetes. We found no statistically significant associations between dietary or urinary potassium and incident diabetes. Conclusions: In this African-American cohort, we found that aldosterone may modify the association between serum potassium and incident diabetes. In participants with normal aldosterone, high-normal serum potassium was associated with a lower risk of diabetes than was low-normal serum potassium. Additional studies are warranted to determine whether serum potassium is a modifiable risk factor that could be a target for diabetes prevention. This trial was registered at clinicaltrials.gov as NCT00415415. PMID:27974310

  17. Distributed gas sensing with optical fibre photothermal interferometry.

    PubMed

    Lin, Yuechuan; Liu, Fei; He, Xiangge; Jin, Wei; Zhang, Min; Yang, Fan; Ho, Hoi Lut; Tan, Yanzhen; Gu, Lijuan

    2017-12-11

    We report the first distributed optical fibre trace-gas detection system based on photothermal interferometry (PTI) in a hollow-core photonic bandgap fibre (HC-PBF). Absorption of a modulated pump propagating in the gas-filled HC-PBF generates distributed phase modulation along the fibre, which is detected by a dual-pulse heterodyne phase-sensitive optical time-domain reflectometry (OTDR) system. Quasi-distributed sensing experiment with two 28-meter-long HC-PBF sensing sections connected by single-mode transmission fibres demonstrated a limit of detection (LOD) of ∼10 ppb acetylene with a pump power level of 55 mW and an effective noise bandwidth (ENBW) of 0.01 Hz, corresponding to a normalized detection limit of 5.5ppb⋅W/Hz. Distributed sensing experiment over a 200-meter-long sensing cable made of serially connected HC-PBFs demonstrated a LOD of ∼ 5 ppm with 62.5 mW peak pump power and 11.8 Hz ENBW, or a normalized detection limit of 312ppb⋅W/Hz. The spatial resolution of the current distributed detection system is limited to ∼ 30 m, but it is possible to reduce down to 1 meter or smaller by optimizing the phase detection system.

  18. Incidence of postoperative pain after use of calcium hydroxide mixed with normal saline or 0.2% chlorhexidine digluconate as intracanal medicament in the treatment of apical periodontitis.

    PubMed

    Menakaya, Ifeoma Nkiruka; Oderinu, Olabisi Hajarat; Adegbulugbe, Ilemobade Cyril; Shaba, Olufemi Peter

    2015-10-01

    To compare the incidence of postoperative pain after the use of calcium hydroxide powder mixed with normal saline or 0.2% chlorhexidine digluconate as intracanal medicament. Fifty-five subjects aged 17-60 years with teeth diagnosed to have apical periodontitis. Two-visit conventional root canal treatment of seventy teeth. The teeth were divided by randomization (balloting) into two groups: control group and experimental group, each with thirty-five teeth treated with calcium hydroxide mixed with normal saline or with 0.2% chlorhexidine digluconate as intracanal medicament respectively. Incidence of postoperative pain was assessed using the universal pain assessment tool and whether or not analgesic was taken. Incidence of post-operative pain. Postoperative pain occurred only at 1-day and 1-week reviews. In the control group, the overall incidence of pain was the same at both review periods (5.7%), while the experimental group showed a slight decrease in incidence between 1-day (17.2%) and 1-week (11.4%) reviews. Incidence of flare-ups was more in the experimental group (11.4%) than in the control group (5.7%). No significant statistical differences between the two groups were observed (p > 0.05). The incidence of postoperative pain was lower in the normal saline treatment group, but the difference was not statistically significant.

  19. Magnetic field pitch angle and perpendicular velocity measurements from multi-point time-delay estimation of poloidal correlation reflectometry

    NASA Astrophysics Data System (ADS)

    Prisiazhniuk, D.; Krämer-Flecken, A.; Conway, G. D.; Happel, T.; Lebschy, A.; Manz, P.; Nikolaeva, V.; Stroth, U.; the ASDEX Upgrade Team

    2017-02-01

    In fusion machines, turbulent eddies are expected to be aligned with the direction of the magnetic field lines and to propagate in the perpendicular direction. Time delay measurements of density fluctuations can be used to calculate the magnetic field pitch angle α and perpendicular velocity {{v}\\bot} profiles. The method is applied to poloidal correlation reflectometry installed at ASDEX Upgrade and TEXTOR, which measure density fluctuations from poloidally and toroidally separated antennas. Validation of the method is achieved by comparing the perpendicular velocity (composed of the E× B drift and the phase velocity of turbulence {{v}\\bot}={{v}E× B}+{{v}\\text{ph}} ) with Doppler reflectometry measurements and with neoclassical {{v}E× B} calculations. An important condition for the application of the method is the presence of turbulence with a sufficiently long decorrelation time. It is shown that at the shear layer the decorrelation time is reduced, limiting the application of the method. The magnetic field pitch angle measured by this method shows the expected dependence on the magnetic field, plasma current and radial position. The profile of the pitch angle reproduces the expected shape and values. However, comparison with the equilibrium reconstruction code cliste suggests an additional inclination of turbulent eddies at the pedestal position (2-3°). This additional angle decreases towards the core and at the edge.

  20. Experimental studies of toroidal correlations of plasma density fluctuations along the magnetic field lines in the T-10 tokamak and first results of numerical modeling

    NASA Astrophysics Data System (ADS)

    Buldakov, M. A.; Vershkov, V. A.; Isaev, M. Yu; Shelukhin, D. A.

    2017-10-01

    The antenna system of reflectometry diagnostics at the T-10 tokamak allows to study long-range toroidal correlations of plasma density fluctuations along the magnetic field lines. The antenna systems are installed in two poloidal cross-sections of the vacuum chamber separated by a 90° angle in the toroidal direction. The experiments, which were conducted at the low field side, showed that the high level of toroidal correlations is observed only for quasi-coherent fluctuations. However, broadband and stochastic low frequency fluctuations are not correlated. Numerical modeling of the plasma turbulence structure in the T-10 tokamak was conducted to interpret the experimental results and take into account non-locality of reflectometry measurements. In the model used, it was assumed that the magnitudes of density fluctuations are constant along the magnetic field lines. The 2D full-wave Tamic-RTH code was used to model the reflectometry signals. High level of correlations for quasi-coherent fluctuations was obtained during the modeling, which agrees with the experimental observations. However, the performed modeling also predicts high level of correlations for broadband fluctuations, which contradicts the experimental data. The modeling showed that the effective reflection radius, from which the information on quasi-coherent plasma turbulence is obtained, is shifted outwards from the reflection radius by approximately 7 mm.

  1. A Polarization-Dependent Normal Incident Quantum Cascade Detector Enhanced Via Metamaterial Resonators.

    PubMed

    Wang, Lei; Zhai, Shen-Qiang; Wang, Feng-Jiao; Liu, Jun-Qi; Liu, Shu-Man; Zhuo, Ning; Zhang, Chuan-Jin; Wang, Li-Jun; Liu, Feng-Qi; Wang, Zhan-Guo

    2016-12-01

    The design, fabrication, and characterization of a polarization-dependent normal incident quantum cascade detector coupled via complementary split-ring metamaterial resonators in the infrared regime are presented. The metamaterial structure is designed through three-dimensional finite-difference time-domain method and fabricated on the top metal contact, which forms a double-metal waveguide together with the metallic ground plane. With normal incidence, significant enhancements of photocurrent response are obtained at the metamaterial resonances compared with the 45° polished edge coupling device. The photocurrent response enhancements exhibit clearly polarization dependence, and the largest response enhancement factor of 165% is gained for the incident light polarized parallel to the split-ring gap.

  2. Ion distribution in dry polyelectrolyte multilayers: a neutron reflectometry study

    DOE PAGES

    Ghoussoub, Yara E.; Zerball, Maximilian; Fares, Hadi M.; ...

    2018-02-09

    Counterions were found to be uniformly distributed in polycation-terminated films of poly(diallyldimethylammonium) and poly(styrenesulfonate) prepared on silicon wafers using layer-by-layer adsorption.

  3. Direct detection of a transport-blocking trap in a nanoscaled silicon single-electron transistor by radio-frequency reflectometry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Villis, B. J.; Sanquer, M.; Jehl, X.

    2014-06-09

    The continuous downscaling of transistors results in nanoscale devices which require fewer and fewer charged carriers for their operation. The ultimate charge controlled device, the single-electron transistor (SET), controls the transfer of individual electrons. It is also the most sensitive electrometer, and as a result the electron transport through it can be dramatically affected by nearby charges. Standard direct-current characterization techniques, however, are often unable to unambiguously detect and resolve the origin of the observed changes in SET behavior arising from changes in the charge state of a capacitively coupled trap. Using a radio-frequency (RF) reflectometry technique, we are ablemore » to unequivocally detect this process, in very close agreement with modeling of the trap's occupation probability.« less

  4. Distributed Optical Fiber Sensors Based on Optical Frequency Domain Reflectometry: A review

    PubMed Central

    Wang, Chenhuan; Liu, Kun; Jiang, Junfeng; Yang, Di; Pan, Guanyi; Pu, Zelin; Liu, Tiegen

    2018-01-01

    Distributed optical fiber sensors (DOFS) offer unprecedented features, the most unique one of which is the ability of monitoring variations of the physical and chemical parameters with spatial continuity along the fiber. Among all these distributed sensing techniques, optical frequency domain reflectometry (OFDR) has been given tremendous attention because of its high spatial resolution and large dynamic range. In addition, DOFS based on OFDR have been used to sense many parameters. In this review, we will survey the key technologies for improving sensing range, spatial resolution and sensing performance in DOFS based on OFDR. We also introduce the sensing mechanisms and the applications of DOFS based on OFDR including strain, stress, vibration, temperature, 3D shape, flow, refractive index, magnetic field, radiation, gas and so on. PMID:29614024

  5. Ultra-broadband phase-sensitive optical time-domain reflectometry with a temporally sequenced multi-frequency source.

    PubMed

    Wang, Zhaoyong; Pan, Zhengqing; Fang, Zujie; Ye, Qing; Lu, Bin; Cai, Haiwen; Qu, Ronghui

    2015-11-15

    A phase-sensitive optical time-domain reflectometry (Φ-OTDR) with a temporally sequenced multi-frequency (TSMF) source is proposed. This technique can improve the system detection bandwidth without the sensing range decreasing. Up to 0.5 MHz detection bandwidth over 9.6 km is experimentally demonstrated as an example. To the best of our knowledge, this is the first time that such a high detection bandwidth over such a long sensing range is reported in Φ-OTDR-based distributed vibration sensing. The technical issues of TSMF Φ-OTDR are discussed in this Letter. This technique will help Φ-OTDR find new important foreground in long-haul distributed broadband-detection applications, such as structural-health monitoring and partial-discharge online monitoring of high voltage power cables.

  6. Dielectric properties of benzylamine in 1,2,6-hexanetriol mixture using time domain reflectometry technique

    NASA Astrophysics Data System (ADS)

    Swami, M. B.; Hudge, P. G.; Pawar, V. P.

    The dielectric properties of binary mixtures of benzylamine-1,2,6-hexantriol mixtures at different volume fractions of 1,2,6-hexanetriol have been measured using Time Domain Reflectometry (TDR) technique in the frequency range of 10 MHz to 30 GHz. Complex permittivity spectra were fitted using Havriliak-Negami equation. By using least square fit method the dielectric parameters such as static dielectric constant (ɛ0), dielectric constant at high frequency (ɛ∞), relaxation time τ (ps) and relaxation distribution parameter (β) were extracted from complex permittivity spectra at 25∘C. The intramolecular interaction of different molecules has been discussed using the Kirkwood correlation factor, Bruggeman factor. The Kirkwood correlation factor (gf) and effective Kirkwood correlation factor (geff) indicate the dipole ordering of the binary mixtures.

  7. Sidelobe apodization in optical pulse compression reflectometry for fiber optic distributed acoustic sensing.

    PubMed

    Mompó, Juan José; Martín-López, Sonia; González-Herráez, Miguel; Loayssa, Alayn

    2018-04-01

    We demonstrate a technique to reduce the sidelobes in optical pulse compression reflectometry for distributed acoustic sensing. The technique is based on using a Gaussian probe pulse with linear frequency modulation. This is shown to improve the sidelobe suppression by 13 dB compared to the use of square pulses without any significant penalty in terms of spatial resolution. In addition, a 2.25 dB enhancement in signal-to-noise ratio is calculated compared to the use of receiver-side windowing. The method is tested by measuring 700 Hz vibrations with a 140  nε amplitude at the end of a 50 km fiber sensing link with 34 cm spatial resolution, giving a record 147,058 spatially resolved points.

  8. Distributed Optical Fiber Sensors Based on Optical Frequency Domain Reflectometry: A review.

    PubMed

    Ding, Zhenyang; Wang, Chenhuan; Liu, Kun; Jiang, Junfeng; Yang, Di; Pan, Guanyi; Pu, Zelin; Liu, Tiegen

    2018-04-03

    Distributed optical fiber sensors (DOFS) offer unprecedented features, the most unique one of which is the ability of monitoring variations of the physical and chemical parameters with spatial continuity along the fiber. Among all these distributed sensing techniques, optical frequency domain reflectometry (OFDR) has been given tremendous attention because of its high spatial resolution and large dynamic range. In addition, DOFS based on OFDR have been used to sense many parameters. In this review, we will survey the key technologies for improving sensing range, spatial resolution and sensing performance in DOFS based on OFDR. We also introduce the sensing mechanisms and the applications of DOFS based on OFDR including strain, stress, vibration, temperature, 3D shape, flow, refractive index, magnetic field, radiation, gas and so on.

  9. Detection of tunnel excavation using fiber optic reflectometry: experimental validation

    NASA Astrophysics Data System (ADS)

    Linker, Raphael; Klar, Assaf

    2013-06-01

    Cross-border smuggling tunnels enable unmonitored movement of people and goods, and pose a severe threat to homeland security. In recent years, we have been working on the development of a system based on fiber- optic Brillouin time domain reflectometry (BOTDR) for detecting tunnel excavation. In two previous SPIE publications we have reported the initial development of the system as well as its validation using small-scale experiments. This paper reports, for the first time, results of full-scale experiments and discusses the system performance. The results confirm that distributed measurement of strain profiles in fiber cables buried at shallow depth enable detection of tunnel excavation, and by proper data processing, these measurements enable precise localization of the tunnel, as well as reasonable estimation of its depth.

  10. Dimensional scaling for impact cratering and perforation

    NASA Technical Reports Server (NTRS)

    Watts, Alan; Atkinson, Dale; Rieco, Steve

    1993-01-01

    This report summarizes the development of two physics-based scaling laws for describing crater depths and diameters caused by normal incidence impacts into aluminum and TFE Teflon. The report then describes equations for perforations in aluminum and TFE Teflon for normal impacts. Lastly, this report also studies the effects of non-normal incidence on cratering and perforation.

  11. Two-dimensional ultrahigh-density X-ray optical memory.

    PubMed

    Bezirganyan, Hakob P; Bezirganyan, Siranush E; Bezirganyan, Hayk H; Bezirganyan, Petros H

    2007-01-01

    Most important aspect of nanotechnology applications in the information ultrahigh storage is the miniaturization of data carrier elements of the storage media with emphasis on the long-term stability. Proposed two-dimensional ultrahigh-density X-ray optical memory, named X-ROM, with long-term stability is an information carrier basically destined for digital data archiving. X-ROM is a semiconductor wafer, in which the high-reflectivity nanosized X-ray mirrors are embedded. Data are encoded due to certain positions of the mirrors. Ultrahigh-density data recording procedure can e.g., be performed via mask-less zone-plate-array lithography (ZPAL), spatial-phase-locked electron-beam lithography (SPLEBL), or focused ion-beam lithography (FIB). X-ROM manufactured by nanolithography technique is a write-once memory useful for terabit-scale memory applications, if the surface area of the smallest recording pits is less than 100 nm2. In this case the X-ROM surface-storage capacity of a square centimetre becomes by two orders of magnitude higher than the volumetric data density really achieved for three-dimensional optical data storage medium. Digital data read-out procedure from proposed X-ROM can e.g., be performed via glancing-angle incident X-ray micro beam (GIX) using the well-developed X-ray reflectometry technique. In presented theoretical paper the crystal-analyser operating like an image magnifier is added to the set-up of X-ROM data handling system for the purpose analogous to case of application the higher numerical aperture objective in optical data read-out system. We also propose the set-up of the X-ROM readout system based on more the one incident X-ray micro beam. Presented scheme of two-beam data handling system, which operates on two mutually perpendicular well-collimated monochromatic incident X-ray micro beams, essentially increases the reliability of the digital information read-out procedure. According the graphs of characteristic functions presented in paper, one may choose optimally the incident radiation wavelength, as well as the angle of incidence of X-ray micro beams, appropriate for proposed digital data read-out procedure.

  12. Replication of Low Density Electroformed Normal Incidence Optics

    NASA Technical Reports Server (NTRS)

    Ritter, Joseph M.

    2000-01-01

    Replicated electroformed light-weight nickel alloy mirrors can have high strength, low areal density (<3kg/m2), smooth finish, and controllable alloy composition. Progress at NASA MSFC SOMTC in developing normal incidence replicated Nickel mirrors will be reported.

  13. Influence of incident angle on the decoding in laser polarization encoding guidance

    NASA Astrophysics Data System (ADS)

    Zhou, Muchun; Chen, Yanru; Zhao, Qi; Xin, Yu; Wen, Hongyuan

    2009-07-01

    Dynamic detection of polarization states is very important for laser polarization coding guidance systems. In this paper, a set of dynamic polarization decoding and detection system used in laser polarization coding guidance was designed. Detection process of the normal incident polarized light is analyzed with Jones Matrix; the system can effectively detect changes in polarization. Influence of non-normal incident light on performance of polarization decoding and detection system is studied; analysis showed that changes in incident angle will have a negative impact on measure results, the non-normal incident influence is mainly caused by second-order birefringence and polarization sensitivity effect generated in the phase delay and beam splitter prism. Combined with Fresnel formula, decoding errors of linearly polarized light, elliptically polarized light and circularly polarized light with different incident angles into the detector are calculated respectively, the results show that the decoding errors increase with increase of incident angle. Decoding errors have relations with geometry parameters, material refractive index of wave plate, polarization beam splitting prism. Decoding error can be reduced by using thin low-order wave-plate. Simulation of detection of polarized light with different incident angle confirmed the corresponding conclusions.

  14. Angle-selective all-dielectric Huygens’ metasurfaces

    NASA Astrophysics Data System (ADS)

    Arslan, D.; Chong, K. E.; Miroshnichenko, A. E.; Choi, D.-Y.; Neshev, D. N.; Pertsch, T.; Kivshar, Y. S.; Staude, I.

    2017-11-01

    We experimentally and numerically study the angularly resolved transmission properties of dielectric metasurfaces consisting of silicon nanodisks which support electric and magnetic dipolar Mie-type resonances in the near-infrared spectral range. First, we concentrate on Huygens’ metasurfaces which are characterised by a spectral overlap of the fundamental electric and magnetic dipole resonances of the silicon nanodisks at normal incidence. Huygens’ metasurfaces exhibit a high transmitted intensity over the spectral width of the resonances due to impedance matching, while the transmitted phase shows a variation of 2π as the wavelength is swept across the width of the resonances. We observe that the transmittance of the Huygens’ metasurfaces depends on the incidence angle and is sensitive to polarisation for non-normal incidence. As the incidence angle is increased starting from normal incidence, the two dipole resonances are shifted out of the spectral overlap and the resonant features appear as pronounced transmittance minima. Next, we consider a metasurface with an increased nanodisk radius as compared to the Huygens’ metasurface, which supports spectrally separate electric and magnetic dipole resonances at normal incidence. We show that for TM polarisation, we can shift the resonances of this metasurface into spectral overlap and regain the high resonant transmittance characteristic of Huygens’ metasurfaces at a particular incidence angle. Furthermore, both metasurfaces are demonstrated to reject all TM polarised light incident under angles other than the design overlap angle at their respective operation frequency. Our experimental observations are in good qualitative agreement with numerical calculations.

  15. Model Based Inference for Wire Chafe Diagnostics

    NASA Technical Reports Server (NTRS)

    Schuet, Stefan R.; Wheeler, Kevin R.; Timucin, Dogan A.; Wysocki, Philip F.; Kowalski, Marc Edward

    2009-01-01

    Presentation for Aging Aircraft conference covering chafing fault diagnostics using Time Domain Reflectometry. Laboratory setup and experimental methods are presented, along with initial results that summarize fault modeling and detection capabilities.

  16. Using the Spatial Persistence of Soil Moisture Patterns to Estimate Catchment Soil Moisture in Semi-arid Areas

    NASA Astrophysics Data System (ADS)

    Willgoose, G. R.

    2006-12-01

    In humid catchments the spatial distribution of soil water is dominated by subsurface lateral fluxes, which leads to a persistent spatial pattern of soil moisture principally described by the topographic index. In contrast, semi-arid, and dryer, catchments are dominated by vertical fluxes (infiltration and evapotranspiration) and persistent spatial patterns, if they exist, are subtler. In the first part of this presentation the results of a reanalysis of a number of catchment-scale long-term spatially-distributed soil moisture data sets are presented. We concentrate on Tarrawarra and SASMAS, both catchments in Australia that are water-limited for at least part of the year and which have been monitored using a variety of technologies. Using the data from permanently installed instruments (neutron probe and reflectometry) both catchments show persistent patterns at the 1-3 year timescale. This persistent pattern is not evident in the field campaign data where field portable instruments (reflectometry) instruments were used. We argue, based on high-resolution soil moisture semivariograms, that high short-distance variability (100mm scale) means that field portable instrument cannot be replaced at the same location with sufficient accuracy to ensure deterministic repeatability of soil moisture measurements from campaign to campaign. The observed temporal persistence of the spatial pattern can be caused by; (1) permanent features of the landscape (e.g. vegetation, soils), or (2) long term memory in the soil moisture store. We argue that it is permanent in which case it is possible to monitor the soil moisture status of a catchment using a single location measurement (continuous in time) of soil moisture using a permanently installed reflectometry instrument. This instrument will need to be calibrated to the catchment averaged soil moisture but the temporal persistence of the spatial pattern of soil moisture will mean that this calibration will be deterministically stable with time. In the second part of this presentation we will explore aspects of the calibration using data from the SASMAS site using the multiscale spatial resolution data (100m to 10km) provided by permanently installed reflectometry instruments, and how this single site measurement technique may complement satellite data.

  17. Simultaneous determination of hemolysis and hematocrit in extracorporeal circulation by plasma surface reflectance spectroscopy.

    PubMed

    Sakota, Daisuke; Kani, Yuki; Kosaka, Ryo; Nishida, Masahiro; Maruyama, Osamu

    2013-01-01

    To achieve quantitative non-invasive optical diagnosis of blood abnormalities during extracorporeal circulation therapies, plasma surface reflectance spectroscopy was developed by implementing oblique-incidence optical fiber reflectometry on the surface of circulating blood. The reflected light in the wavelength range from 450 to 600 nm changed with respect to the plasma free hemoglobin level and could be used to quantify the free hemoglobin at an accuracy of 5.7 ± 3.5 mg/dL. In contrast, the spectrum did not changed by varying the hematocrit. In the wavelength range from 600 to 800 nm, the obtained spectrum was affected by both the hematocrit change and hemolysis. The linear correlation between the hematocrit value and the spectrum was confirmed at R(2) = 0.99. The feasibility of determining of the hematocrit of arbitrary hemolyzed blood was confirmed. The developed system permits the extraction of the optical characteristics of both plasma and red blood cells without centrifugation. The study establishes non-invasive optical diagnostics capable of analyzing the optical properties of both plasma and red blood cells.

  18. A versatile UHV transport and measurement chamber for neutron reflectometry under UHV conditions

    NASA Astrophysics Data System (ADS)

    Syed Mohd, A.; Pütter, S.; Mattauch, S.; Koutsioubas, A.; Schneider, H.; Weber, A.; Brückel, T.

    2016-12-01

    We report on a versatile mini ultra-high vacuum (UHV) chamber which is designed to be used on the MAgnetic Reflectometer with high Incident Angle of the Jülich Centre for Neutron Science at Heinz Maier-Leibnitz Zentrum in Garching, Germany. Samples are prepared in the adjacent thin film laboratory by molecular beam epitaxy and moved into the compact chamber for transfer without exposure to ambient air. The chamber is based on DN 40 CF flanges and equipped with sapphire view ports, a small getter pump, and a wobble stick, which serves also as sample holder. Here, we present polarized neutron reflectivity measurements which have been performed on Co thin films at room temperature in UHV and in ambient air in a magnetic field of 200 mT and in the Q-range of 0.18 Å-1. The results confirm that the Co film is not contaminated during the polarized neutron reflectivity measurement. Herewith it is demonstrated that the mini UHV transport chamber also works as a measurement chamber which opens new possibilities for polarized neutron measurements under UHV conditions.

  19. Complex EUV imaging reflectometry: spatially resolved 3D composition determination and dopant profiling with a tabletop 13nm source

    NASA Astrophysics Data System (ADS)

    Porter, Christina L.; Tanksalvala, Michael; Gerrity, Michael; Miley, Galen P.; Esashi, Yuka; Horiguchi, Naoto; Zhang, Xiaoshi; Bevis, Charles S.; Karl, Robert; Johnsen, Peter; Adams, Daniel E.; Kapteyn, Henry C.; Murnane, Margaret M.

    2018-03-01

    With increasingly 3D devices becoming the norm, there is a growing need in the semiconductor industry and in materials science for high spatial resolution, non-destructive metrology techniques capable of determining depth-dependent composition information on devices. We present a solution to this problem using ptychographic coherent diffractive imaging (CDI) implemented using a commercially available, tabletop 13 nm source. We present the design, simulations, and preliminary results from our new complex EUV imaging reflectometer, which uses coherent 13 nm light produced by tabletop high harmonic generation. This tool is capable of determining spatially-resolved composition vs. depth profiles for samples by recording ptychographic images at multiple incidence angles. By harnessing phase measurements, we can locally and nondestructively determine quantities such as device and thin film layer thicknesses, surface roughness, interface quality, and dopant concentration profiles. Using this advanced imaging reflectometer, we can quantitatively characterize materials-sciencerelevant and industry-relevant nanostructures for a wide variety of applications, spanning from defect and overlay metrology to the development and optimization of nano-enhanced thermoelectric or spintronic devices.

  20. A versatile UHV transport and measurement chamber for neutron reflectometry under UHV conditions.

    PubMed

    Syed Mohd, A; Pütter, S; Mattauch, S; Koutsioubas, A; Schneider, H; Weber, A; Brückel, T

    2016-12-01

    We report on a versatile mini ultra-high vacuum (UHV) chamber which is designed to be used on the MAgnetic Reflectometer with high Incident Angle of the Jülich Centre for Neutron Science at Heinz Maier-Leibnitz Zentrum in Garching, Germany. Samples are prepared in the adjacent thin film laboratory by molecular beam epitaxy and moved into the compact chamber for transfer without exposure to ambient air. The chamber is based on DN 40 CF flanges and equipped with sapphire view ports, a small getter pump, and a wobble stick, which serves also as sample holder. Here, we present polarized neutron reflectivity measurements which have been performed on Co thin films at room temperature in UHV and in ambient air in a magnetic field of 200 mT and in the Q-range of 0.18 Å -1 . The results confirm that the Co film is not contaminated during the polarized neutron reflectivity measurement. Herewith it is demonstrated that the mini UHV transport chamber also works as a measurement chamber which opens new possibilities for polarized neutron measurements under UHV conditions.

  1. Replication of Low Density Electroformed Normal Incidence Optics

    NASA Technical Reports Server (NTRS)

    Ritter, Joseph M.; Burdine, Robert (Technical Monitor)

    2001-01-01

    Replicated electroformed light-weight nickel alloy mirrors can have high strength, low areal density (less than 3kg/m2), smooth finish, and controllable alloy composition. Progress at NASA MSFC SOMTC in developing normal incidence replicated Nickel mirrors will be reported.

  2. The nature of crustal boundaries: combined interpretation of wide-angle and normal-incidence seismic data

    NASA Astrophysics Data System (ADS)

    Long, Roger E.; Matthews, Patricia A.; Graham, Daniel P.

    1994-04-01

    After a few seconds two-way traveltime, normal-incidence seismic reflection sections are composed mainly of assemblages of short reflections. Very rarely are seen continuous reflections that might correspond to the Moho or a mid-crustal discontinuity. The inferred continuity of these boundaries has traditionally come from refraction seismology. There is now a body of high quality, coincident wide-angle and normal-incidence seismic data that have been recorded with 50-100 m shot spacing and with high frequency sources (e.g. MOBIL, BABEL). The complexity and characteristics of the wide-angle arrivals seen on these data suggest that they do not originate from continuous boundaries. It is suggested that these arrivals are reflections from the same assemblage of short length reflectors that are responsible for normal-incidence reflections. Seismic velocities below the middle crust may (1) change corresponding to normal-incidence reflectivity, or (2) generally increase with depth with localised sills or lens structures of different velocity accounting for the observed reflections. Wide-angle arrivals that have traditionally been identified as reflections from crustal boundaries (e.g. the mid-crust and Moho) and which were considered indicative of a sharp velocity discontinuity from continuous boundaries, may instead result from a concentration of lamellae.

  3. Agricultural Geophysics

    USDA-ARS?s Scientific Manuscript database

    The four geophysical methods predominantly used for agricultural purposes are resistivity, electromagnetic induction, ground penetrating radar (GPR), and time domain reflectometry (TDR). Resistivity and electromagnetic induction methods are typically employed to map lateral variations of apparent so...

  4. [Idiopathic normal pressure hydrocephalus: High incidence in people over 80 years of age].

    PubMed

    Aragonès, Josep Maria; Altimiras, Jacint; Alonso, Francisco; Roura, Pere; Alfonso, Sebastián; Bajo, Lorena

    Idiopathic normal pressure hydrocephalus is usually observed in adults over 60 years of age. The highest incidence of cases is between 70 and 80 years-old, and it could be under-diagnosed in over 80 year-olds. A description is presented on the overall incidence and age group incidence, the delay in the diagnosis, and main outcomes. A descriptive study was performed on patients with idiopathic normal pressure hydrocephalus, in the population of Osona County during the years 2010-2015. The annual incidence rate was 4.43 per 100,000 inhabitants. The incidence increased with age; from 8.09 per 100,000 in the 60 to 69 years age group, to 23.61 per 100,000 in the 70-79 years age group of, and to 37.02 per 100,000 in the 80-89 years age. The delay in the diagnosis was 15.01 ± 10.35 months. All the patients improved after surgery, but only 73.3% of the patients maintained the improvement after one year. Idiopathic normal pressure hydrocephalus is an age related disease and probably underdiagnosed in the elderly. An early diagnosis and a clinical suspicion are essential in patients over 80 years old. Copyright © 2017 SEGG. Publicado por Elsevier España, S.L.U. All rights reserved.

  5. Imaging crystal/spectral line search

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Koch, J.A.

    1998-02-16

    The following table is a compilation of chance coincidences between x- ray line wavelengths and crystal planes which will reflect those wavelengths near normal incidence. The motivation is to explore the possibilities for expanding the range of choices for near normal incidence x-ray crystal imaging.

  6. Inclinometer--time-domain reflectometry comparative study : executive summary report.

    DOT National Transportation Integrated Search

    2004-10-01

    Slope stability is an ongoing issue in : hilly or mountainous terrains with clay : rich soil, constructed embankments, : fluctuating temperature, and changing : soil moisture conditions. Landslides : constitute a major geologic hazard, : occurring in...

  7. Inclinometer - Time Domain Reflectometry Comparative Study : Executive Summary Report

    DOT National Transportation Integrated Search

    2004-10-01

    Slope stability is an ongoing issue in : hilly or mountainous terrains with clay : rich soil, constructed embankments, : fluctuating temperature, and changing : soil moisture conditions. Landslides : constitute a major geologic hazard, : occurring in...

  8. X-ray study of the structure of phospholipid monolayers on the water surface

    NASA Astrophysics Data System (ADS)

    Asadchikov, V. E.; Tikhonov, A. M.; Volkov, Yu. O.; Roshchin, B. S.; Ermakov, Yu. A.; Rudakova, E. B.; D'yachkova, I. G.; Nuzhdin, A. D.

    2017-10-01

    The possibility of laboratory X-ray reflectometry study of the structure of dimyristoyl phosphatidylserine (DMPS) phospholipid monolayers on the water surface in various phase states has been demonstrated.

  9. Adaptive array technique for differential-phase reflectometry in QUEST

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Idei, H., E-mail: idei@triam.kyushu-u.ac.jp; Hanada, K.; Zushi, H.

    2014-11-15

    A Phased Array Antenna (PAA) was considered as launching and receiving antennae in reflectometry to attain good directivity in its applied microwave range. A well-focused beam was obtained in a launching antenna application, and differential-phase evolution was properly measured by using a metal reflector plate in the proof-of-principle experiment at low power test facilities. Differential-phase evolution was also evaluated by using the PAA in the Q-shu University Experiment with Steady State Spherical Tokamak (QUEST). A beam-forming technique was applied in receiving phased-array antenna measurements. In the QUEST device that should be considered as a large oversized cavity, standing wave effectmore » was significantly observed with perturbed phase evolution. A new approach using derivative of measured field on propagating wavenumber was proposed to eliminate the standing wave effect.« less

  10. Design and realization of a sputter deposition system for the in situ- and in operando-use in polarized neutron reflectometry experiments

    NASA Astrophysics Data System (ADS)

    Schmehl, Andreas; Mairoser, Thomas; Herrnberger, Alexander; Stephanos, Cyril; Meir, Stefan; Förg, Benjamin; Wiedemann, Birgit; Böni, Peter; Mannhart, Jochen; Kreuzpaintner, Wolfgang

    2018-03-01

    We report on the realization of a sputter deposition system for the in situ- and in operando-use in polarized neutron reflectometry experiments. Starting with the scientific requirements, which define the general design considerations, the external limitations and boundaries imposed by the available space at a neutron beamline and by the neutron and vacuum compatibility of the used materials, are assessed. The relevant aspects are then accounted for in the realization of our highly mobile deposition system, which was designed with a focus on a quick and simple installation and removability at the beamline. Apart from the general design, the in-vacuum components, the auxiliary equipment and the remote control via a computer, as well as relevant safety aspects are presented in detail.

  11. Low-Coherence Reflectometry for Refractive Index Measurements of Cells in Micro-Capillaries.

    PubMed

    Carpignano, Francesca; Rigamonti, Giulia; Mazzini, Giuliano; Merlo, Sabina

    2016-10-11

    The refractive index of cells provides insights into their composition, organization and function. Moreover, a good knowledge of the cell refractive index would allow an improvement of optical cytometric and diagnostic systems. Although interferometric techniques undoubtedly represent a good solution for quantifying optical path variation, obtaining the refractive index of a population of cells non-invasively remains challenging because of the variability in the geometrical thickness of the sample. In this paper, we demonstrate the use of infrared low-coherence reflectometry for non-invasively quantifying the average refractive index of cell populations gently confined in rectangular glass micro-capillaries. A suspension of human red blood cells in plasma is tested as a reference. As a use example, we apply this technique to estimate the average refractive index of cell populations belonging to epithelial and hematological families.

  12. Simultaneous optical fibre strain and temperature measurements in a hybrid distributed sensor based on Rayleigh and Raman scatteringYjdjvj

    NASA Astrophysics Data System (ADS)

    Gorshkov, B. G.; Taranov, M. A.

    2018-02-01

    A new type of sensor for simultaneous measurements of strain and temperature changes in an optical fibre is proposed. Its operation builds on the use of Raman optical time-domain reflectometry and wavelength-tunable quasi-monochromatic Rayleigh reflectometry implemented using a microelectromechanical filter (MEMS). The sensor configuration includes independent Raman and Rayleigh scattering channels. Our experiments have demonstrated that, at a sensing fibre length near 8 km, spatial resolution of 1-2 m, and measurement time of 10 min, the noise level (standard deviation) is 1.1 μɛ (μm m-1) for the measured tension change (at small temperature deviations) and 0.04 °C for the measured temperature change, which allows for effective sensing of mechanical and temperature influences with improved accuracy.

  13. Radio-frequency measurement in semiconductor quantum computation

    NASA Astrophysics Data System (ADS)

    Han, TianYi; Chen, MingBo; Cao, Gang; Li, HaiOu; Xiao, Ming; Guo, GuoPing

    2017-05-01

    Semiconductor quantum dots have attracted wide interest for the potential realization of quantum computation. To realize efficient quantum computation, fast manipulation and the corresponding readout are necessary. In the past few decades, considerable progress of quantum manipulation has been achieved experimentally. To meet the requirements of high-speed readout, radio-frequency (RF) measurement has been developed in recent years, such as RF-QPC (radio-frequency quantum point contact) and RF-DGS (radio-frequency dispersive gate sensor). Here we specifically demonstrate the principle of the radio-frequency reflectometry, then review the development and applications of RF measurement, which provides a feasible way to achieve high-bandwidth readout in quantum coherent control and also enriches the methods to study these artificial mesoscopic quantum systems. Finally, we prospect the future usage of radio-frequency reflectometry in scaling-up of the quantum computing models.

  14. 1 μs broadband frequency sweeping reflectometry for plasma density and fluctuation profile measurements

    NASA Astrophysics Data System (ADS)

    Clairet, F.; Bottereau, C.; Medvedeva, A.; Molina, D.; Conway, G. D.; Silva, A.; Stroth, U.; ASDEX Upgrade Team; Tore Supra Team; Eurofusion Mst1 Team

    2017-11-01

    Frequency swept reflectometry has reached the symbolic value of 1 μs sweeping time; this performance has been made possible, thanks to an improved control of the ramp voltage driving the frequency source. In parallel, the memory depth of the acquisition system has been upgraded and can provide up to 200 000 signals during a plasma discharge. Additional improvements regarding the trigger delay determination of the acquisition and the voltage ramp linearity required by this ultra-fast technique have been set. While this diagnostic is traditionally dedicated to the plasma electron density profile measurement, such a fast sweeping rate can provide the study of fast plasma events and turbulence with unprecedented time and radial resolution from the edge to the core. Experimental results obtained on ASDEX Upgrade plasmas are presented to demonstrate the performances of the diagnostic.

  15. Improved wavelength coded optical time domain reflectometry based on the optical switch.

    PubMed

    Zhu, Ninghua; Tong, Youwan; Chen, Wei; Wang, Sunlong; Sun, Wenhui; Liu, Jianguo

    2014-06-16

    This paper presents an improved wavelength coded time-domain reflectometry based on the 2 × 1 optical switch. In this scheme, in order to improve the signal-noise-ratio (SNR) of the beat signal, the improved system used an optical switch to obtain wavelength-stable, low-noise and narrow optical pulses for probe and reference. Experiments were set up to demonstrate a spatial resolution of 2.5m within a range of 70km and obtain the beat signal with line width narrower than 15 MHz within a range of 50 km in fiber break detection. A system for wavelength-division-multiplexing passive optical network (WDM-PON) monitoring was also constructed to detect the fiber break of different channels by tuning the current applied on the gating section of the distributed Bragg reflector (DBR) laser.

  16. Low-Coherence Reflectometry for Refractive Index Measurements of Cells in Micro-Capillaries

    PubMed Central

    Carpignano, Francesca; Rigamonti, Giulia; Mazzini, Giuliano; Merlo, Sabina

    2016-01-01

    The refractive index of cells provides insights into their composition, organization and function. Moreover, a good knowledge of the cell refractive index would allow an improvement of optical cytometric and diagnostic systems. Although interferometric techniques undoubtedly represent a good solution for quantifying optical path variation, obtaining the refractive index of a population of cells non-invasively remains challenging because of the variability in the geometrical thickness of the sample. In this paper, we demonstrate the use of infrared low-coherence reflectometry for non-invasively quantifying the average refractive index of cell populations gently confined in rectangular glass micro-capillaries. A suspension of human red blood cells in plasma is tested as a reference. As a use example, we apply this technique to estimate the average refractive index of cell populations belonging to epithelial and hematological families. PMID:27727172

  17. Octonacci photonic crystals with negative refraction index materials

    NASA Astrophysics Data System (ADS)

    Brandão, E. R.; Vasconcelos, M. S.; Anselmo, D. H. A. L.

    2016-12-01

    We investigate the optical transmission spectra for s-polarized (TE) and p-polarized (TM) waves in one-dimensional photonic quasicrystals on a quasiperiodic multilayer structure made up by alternate layers of SiO2 and metamaterials, organized by following the Octonacci sequence. Maxwell's equations and the transfer-matrix technique are used to derive the transmission spectra for the propagation of normally and obliquely incident optical fields. We assume Drude-Lorentz-type dispersive response for the dielectric permittivity and magnetic permeability of the metamaterials. For normally incident waves, we observe that the spectra does not have self-similar behavior or mirror symmetry and it also features the absence of optical band gap. Also for normally incident waves, we show regions of full transmittance when the incident angle θC = 0° in a particular frequency range.

  18. The saturation of monochromatic lights obliquely incident on the retina.

    PubMed Central

    Alpern, M; Tamaki, R

    1983-01-01

    Foveal dark-adaptation undertaken to test the hypothesis that the excitation of rods causes the desaturation of 'yellow' lights in a 1 degree field traversing the margin of the pupil, fails to exclude that possibility. The desaturation is largest for a 1 degree outside diameter annular test, is still measurable with a 0.5 degree circular disk, but disappears for a 0.29 degree disk. The supersaturation of obliquely incident 501.2 nm test light follows the opposite pattern; it disappears with an annulus and is largest for a 0.29 degree circular field. It is unlikely that rods replace short-wave sensitive cones in the trichromatic match of an obliquely incident test with normally incident primaries. If rods as well as all three cones species are involved, the matches might not be trichromatic in the strong sense. Grassmann's law of scalar multiplication was tested and shown not to hold for the match of an obliquely incident test with normally incident primaries, though it remains valid whenever, both primaries and test strike the retina at the same angle of incidence (independent of that angle). The result in section 3 (above) cannot be due to rod intrusion. It persists (and becomes more conspicuous) on backgrounds (4.0 log scotopic td) which saturate rods. Moreover obliquely incident 'yellow' lights remain desaturated in intervals in the dark after a full bleach, whilst the test field is below rod threshold. The amount of desaturation does not differ appreciably from that normally found. The assumption of the unified theory of Alpern, Kitahara & Tamaki (1983) that the outer segments of only a single set of three cone species (with acceptance angles wide enough to include the entire exit pupil) contain the visual pigments absorbing both the normally incident primaries and the obliquely incident test is disproved by these results. Failure of Grassmann's law is most conspicuous under the conditions for which the changes in saturation upon changing from normal to oblique incidence are greatest and least when the saturation changes are the smallest. Either all unified theories of the Stiles-Crawford effects are wrong or all the effects of oblique incidence operate at a stage in the visual process at which the effects of radiation of different wave-lengths are no longer compounded by the simple linear laws. PMID:6875976

  19. Submonolayer Quantum Dot Infrared Photodetector

    NASA Technical Reports Server (NTRS)

    Ting, David Z.; Bandara, Sumith V.; Gunapala, Sarath D.; Chang, Yia-Chang

    2010-01-01

    A method has been developed for inserting submonolayer (SML) quantum dots (QDs) or SML QD stacks, instead of conventional Stranski-Krastanov (S-K) QDs, into the active region of intersubband photodetectors. A typical configuration would be InAs SML QDs embedded in thin layers of GaAs, surrounded by AlGaAs barriers. Here, the GaAs and the AlGaAs have nearly the same lattice constant, while InAs has a larger lattice constant. In QD infrared photodetector, the important quantization directions are in the plane perpendicular to the normal incidence radiation. In-plane quantization is what enables the absorption of normal incidence radiation. The height of the S-K QD controls the positions of the quantized energy levels, but is not critically important to the desired normal incidence absorption properties. The SML QD or SML QD stack configurations give more control of the structure grown, retains normal incidence absorption properties, and decreases the strain build-up to allow thicker active layers for higher quantum efficiency.

  20. Incident flux angle induced crystal texture transformation in nanostructured molybdenum films

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, L.; Lu, T.-M.; Wang, G.-C.

    2012-07-15

    Molybdenum films were observed to undergo a dramatic change in crystal texture orientation when the incident flux angle was varied in an oblique angle sputter deposition on amorphous substrates. Reflection high-energy electron diffraction pole figure and scanning electron microscopy were used to analyze in detail the texture orientation of the films. The normal incident deposition resulted in a fiber texture film with the minimum energy (110) crystal plane parallel to the substrate surface. A (110)[110] biaxial texture was observed for the samples grown with low incident angles of less than 45 Degree-Sign , with respect to the surface normal. Onmore » the other hand, for an oblique angle deposition of larger than 60 Degree-Sign , a (111)[112] biaxial texture was observed and appeared to be consistent with a zone T structure where the geometrically fastest growth [001] direction of a crystal plays a dominant role in defining the texture. We argue that a structural transition had occurred when the incident flux was varied from near normal incidence to a large angle.« less

  1. LTPP Computed Parameter: Moisture Content

    DOT National Transportation Integrated Search

    2008-01-01

    A study was conducted to compute in situ soil parameters based on time domain reflectometry (TDR) traces obtained from Long Term Pavement Performance (LTPP) test sections instrumented for the seasonal monitoring program (SMP). Ten TDR sensors were in...

  2. Wavefront Sensing Analysis of Grazing Incidence Optical Systems

    NASA Technical Reports Server (NTRS)

    Rohrbach, Scott; Saha, Timo

    2012-01-01

    Wavefront sensing is a process by which optical system errors are deduced from the aberrations in the image of an ideal source. The method has been used successfully in near-normal incidence, but not for grazing incidence systems. This innovation highlights the ability to examine out-of-focus images from grazing incidence telescopes (typically operating in the x-ray wavelengths, but integrated using optical wavelengths) and determine the lower-order deformations. This is important because as a metrology tool, this method would allow the integration of high angular resolution optics without the use of normal incidence interferometry, which requires direct access to the front surface of each mirror. Measuring the surface figure of mirror segments in a highly nested x-ray telescope mirror assembly is difficult due to the tight packing of elements and blockage of all but the innermost elements to normal incidence light. While this can be done on an individual basis in a metrology mount, once the element is installed and permanently bonded into the assembly, it is impossible to verify the figure of each element and ensure that the necessary imaging quality will be maintained. By examining on-axis images of an ideal point source, one can gauge the low-order figure errors of individual elements, even when integrated into an assembly. This technique is known as wavefront sensing (WFS). By shining collimated light down the optical axis of the telescope and looking at out-of-focus images, the blur due to low-order figure errors of individual elements can be seen, and the figure error necessary to produce that blur can be calculated. The method avoids the problem of requiring normal incidence access to the surface of each mirror segment. Mirror figure errors span a wide range of spatial frequencies, from the lowest-order bending to the highest order micro-roughness. While all of these can be measured in normal incidence, only the lowest-order contributors can be determined through this WFS technique.

  3. Imaging performance of a normal incidence soft X-ray telescope

    NASA Technical Reports Server (NTRS)

    Henry, J. P.; Spiller, E.; Weisskopf, M.

    1982-01-01

    Measurements are presented of the imaging performance of a normal incidence spherical soft X-ray mirror at BK-alpha (67.6 A). The reflector was a 124-layer coating consisting of alternating Re-W alloy and C layers with a protective C overcoat 34 A thick deposited on a Zerodur substrate. Measurements made at an angle of 1.5 deg off axis with the prototype of the Einstein Observatory high resolution imager reveal the resolution of the mirror to be about 1 arcsec FWHM, with 50% of the reflected power within the detector field of 512 arcsec contained within a diameter of 5 arcsec. The data demonstrate the practicality and potential good performance of normal-incidence soft X-ray optics, and show that the scattering performances of such devices may be as good or better than the best grazing incidence devices.

  4. Spatially Resolved Large Magnetization in Ultrathin BiFeO 3

    DOE PAGES

    Guo, Er-Jia; Petrie, Jonathan R.; Roldan, Manuel A.; ...

    2017-06-19

    Complex interactions across the interface in heterostructures can generate novel functionalities not present in the constituent materials. Here, we create a unique ferromagnetic ground state out of normally antiferromagnetic BiFeO 3 (BFO) by interleaving it with layers of ferromagnetic La 0.7Sr 0.3MnO 3. Intriguingly, we found that the magnetization of BFO was aligned opposite to that of the manganite layers. Based on polarized neutron reflectometry (PNR) depth profiling of custom-designed layers, we obtained a net magnetization in the BFO layers of 275 kA/m (~1.83 B/Fe) at 10 K, which is two times larger than the previously reported values. Additionally, ferromagneticmore » order in the BFO persists up to 200 K, which is much higher than previously seen in BFO heterostructures. Our unprecedented understanding of the evolution of magnetism and functional coupling across the interface between antiferromagnetic and ferromagnetic layers provides a blueprint towards advanced spintronic devices.« less

  5. Development of Surfaces Optically Suitable for Flat Solar Panels

    NASA Technical Reports Server (NTRS)

    Desmet, D.; Jason, A.; Parr, A.

    1977-01-01

    Innovations in reflectometry techniques are described; and the development of an absorbing selective coating is discussed along with details of surface properties. Conclusions as to the parameterization desired for practical applications of selective surfaces are provided.

  6. CORRTEX Diagnostic Deployment for the SPE-III experiment, 24 July 2012: Fielding Report and Preliminary Data Analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sandoval, Thomas D.; Schultz-Fellenz, Emily S.

    2012-08-29

    The Continuous Reflectometry for Radius vs Time Experiments (CORRTEX) diagnostic system was deployed for the third explosives test in the Source Physics Experiment (SPE) sequence to monitor and verify several conditions of the experiment including the detonation velocity of the explosive package and functioning of explosive initiators. Six distance-marked coaxial cables were installed on the SPE-III explosives canister, and key locations documented through along-cable length measurements and photography. CORRTEX uses electrical-pulse time-domain reflectometry to continuously record the two-way transit time (TWTT) of the cables. As the shock front of the detonation advances, the coaxial cable is shorted or destroyed, andmore » the resulting TWTT also decreases. Interpretation of these changes as a function of TWTT can be converted to positional measurements using known parameters of the cables.« less

  7. Modification of ordinary-mode reflectometry system to detect lower-hybrid waves in Alcator C-Mod

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baek, S. G.; Shiraiwa, S.; Parker, R. R.

    2012-10-15

    Backscattering experiments to detect lower-hybrid (LH) waves have been performed in Alcator C-Mod, using the two modified channels (60 GHz and 75 GHz) of an ordinary-mode reflectometry system with newly developed spectral recorders that can continuously monitor spectral power at a target frequency. The change in the baseline of the spectral recorder during the LH wave injection is highly correlated to the strength of the X-mode non-thermal electron cyclotron emission. In high density plasmas where an anomalous drop in the lower hybrid current drive efficiency is observed, the observed backscattered signals are expected to be generated near the last closedmore » flux surface, demonstrating the presence of LH waves within the plasma. This experimental technique can be useful in identifying spatially localized LH electric fields in the periphery of high-density plasmas.« less

  8. Remote sensing of snow using bistatic radar reflectometry

    NASA Astrophysics Data System (ADS)

    Komanduru, Abi

    Snow and ice processes are a critical part of the Earth's hydrological and climate cycles. These processes can serve as an important source of fresh water as well as a cause of flooding. Various missions have been proposed by NASA and ESA for the purpose of remote sensing of snow. This research looks at applying bistatic radar reflectometry to the remote sensing of snow water equivalent. The resulting phase offset from changes in optical path length due to reflection through snow are the primary measurements made. The research uses data from a field campaign in Fraser, CO, involving an instrument collecting direct and reflected from S band during Jan 2015 - Apr 2015. Phase measurements from the field data are made from the two signals and compared to theoretical phase computed from a forward model using in situ data. A moderate correlation (>0.6) is found between the measured and modeled phase.

  9. Active Time Domain Reflectometry for Tamper Indication in Unattended Safeguards Systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sheen, David M.; Smith, Leon E.; Tedeschi, Jonathan R.

    2015-07-14

    The International Atomic Energy Agency (IAEA) continues to expand its use of unattended measurement systems. An increasing number of systems and an expanding family of instruments create challenges in terms of deployment efficiency and the implementation of data authentication measures. In collaboration with the IAEA, tamper-indicating measures to address data-transmission authentication challenges with unattended safeguards systems are under investigation. Pacific Northwest National Laboratory is studying the viability of active time-domain reflectometry (TDR) along two parallel but interconnected paths: (1) swept-frequency TDR as the highly flexible, laboratory gold standard to which field-deployable options can be compared, and (2) a low-cost commerciallymore » available spread-spectrum TDR technology as one option for field implementation. This paper describes the TDR methods under investigation and the associated benchtop test-bed, tampering scenarios of interest,, and viability measurement results to date (e.g., comparison of relative sensitivity to tamper scenarios).« less

  10. Measurement of the acoustic response of a wind instrument with application to bore reconstruction

    NASA Astrophysics Data System (ADS)

    van Walstijn, Maarten; Campbell, Murray

    2002-11-01

    Reconstruction of a bore from measured acoustic response data has been shown to be very useful in studying wind instruments. Such data may be obtained in different ways; directly measuring the frequency-domain response of an acoustic bore has some distinct advantages over directly measuring time-domain data (for example, by pulse reflectometry), but so far has been unsuitable for producing input data for deterministic bore reconstruction algorithms, due to the limited accuracy at high frequencies. In this paper a method is presented for large-bandwidth measurement of the input impedance of a wind instrument using a cylindrical measurement head with multiple wall-mounted microphones. The influence of the number of microphones and the types of calibration impedance on the accuracy will be discussed, and bore reconstructions derived using this technique will be compared with reconstructions obtained using pulse reflectometry. [Work supported by EPSRC.

  11. Neutron reflectometry as a tool to study magnetism.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Felcher, G. P.

    1999-09-21

    Polarized-neutron specular reflectometry (PNR) was developed in the 1980's as a means of measuring magnetic depth profiles in flat films. Starting from simple profiles, and gradually solving structures of greater complexity, PNR has been used to observe or clarify a variety of magnetic phenomena. It has been used to measure the absolute magnetization of films of thickness not exceeding a few atomic planes, the penetration of magnetic fields in micron-thick superconductors, and the detailed magnetic coupling across non-magnetic spacers in multilayers and superlattices. Although PNR is considered a probe of depth dependent magnetic structure, laterally averaged in the plane ofmore » the film, the development of new scattering techniques promises to enable the characterization of lateral magnetic structures. Retaining the depth-sensitivity of specular reflectivity, off-specular reflectivity may be brought to resolve in-plane structures over nanometer to micron length scales.« less

  12. Dielectric relaxation and hydrogen bonding interaction in xylitol-water mixtures using time domain reflectometry

    NASA Astrophysics Data System (ADS)

    Rander, D. N.; Joshi, Y. S.; Kanse, K. S.; Kumbharkhane, A. C.

    2016-01-01

    The measurements of complex dielectric permittivity of xylitol-water mixtures have been carried out in the frequency range of 10 MHz-30 GHz using a time domain reflectometry technique. Measurements have been done at six temperatures from 0 to 25 °C and at different weight fractions of xylitol (0 < W X ≤ 0.7) in water. There are different models to explain the dielectric relaxation behaviour of binary mixtures, such as Debye, Cole-Cole or Cole-Davidson model. We have observed that the dielectric relaxation behaviour of binary mixtures of xylitol-water can be well described by Cole-Davidson model having an asymmetric distribution of relaxation times. The dielectric parameters such as static dielectric constant and relaxation time for the mixtures have been evaluated. The molecular interaction between xylitol and water molecules is discussed using the Kirkwood correlation factor ( g eff ) and thermodynamic parameter.

  13. Performance Analysis of the ITER Plasma Position Reflectometry (PPR) Ex-vessel Transmission Lines

    NASA Astrophysics Data System (ADS)

    Martínez-Fernández, J.; Simonetto, A.; Cappa, Á.; Rincón, M. E.; Cabrera, S.; Ramos, F. J.

    2018-03-01

    As the design of the ITER Plasma Position Reflectometry (PPR) diagnostic progresses, some segments of the transmission line have become fully specified and estimations of their performance can already be obtained. This work presents the calculations carried out for the longest section of the PPR, which is in final state of design and will be the main contributor to the total system performance. Considering the 88.9 mm circular corrugated waveguide (CCWG) that was previously chosen, signal degradation calculations have been performed. Different degradation sources have been studied: ohmic attenuation losses for CCWG; mode conversion losses for gaps, mitre bends, waveguide sag and different types of misalignments; reflection and absorption losses due to microwave windows and coupling losses to free space Gaussian beam. Contributions from all these sources have been integrated to give a global estimation of performance in the transmission lines segments under study.

  14. Investigation of the interpolation method to improve the distributed strain measurement accuracy in optical frequency domain reflectometry systems.

    PubMed

    Cui, Jiwen; Zhao, Shiyuan; Yang, Di; Ding, Zhenyang

    2018-02-20

    We use a spectrum interpolation technique to improve the distributed strain measurement accuracy in a Rayleigh-scatter-based optical frequency domain reflectometry sensing system. We demonstrate that strain accuracy is not limited by the "uncertainty principle" that exists in the time-frequency analysis. Different interpolation methods are investigated and used to improve the accuracy of peak position of the cross-correlation and, therefore, improve the accuracy of the strain. Interpolation implemented by padding zeros on one side of the windowed data in the spatial domain, before the inverse fast Fourier transform, is found to have the best accuracy. Using this method, the strain accuracy and resolution are both improved without decreasing the spatial resolution. The strain of 3 μϵ within the spatial resolution of 1 cm at the position of 21.4 m is distinguished, and the measurement uncertainty is 3.3 μϵ.

  15. Simultaneous reflectometry and interferometry for measuring thin-film thickness and curvature

    NASA Astrophysics Data System (ADS)

    Arends, A. A.; Germain, T. M.; Owens, J. F.; Putnam, S. A.

    2018-05-01

    A coupled reflectometer-interferometer apparatus is described for thin-film thickness and curvature characterization in the three-phase contact line region of evaporating fluids. Validation reflectometry studies are provided for Au, Ge, and Si substrates and thin-film coatings of SiO2 and hydrogel/Ti/SiO2. For interferometry, liquid/air and solid/air interferences are studied, where the solid/air samples consisted of glass/air/glass wedges, cylindrical lenses, and molded polydimethylsiloxane lenses. The liquid/air studies are based on steady-state evaporation experiments of water and isooctane on Si and SiO2/Ti/SiO2 wafers. The liquid thin-films facilitate characterization of both (i) the nano-scale thickness of the absorbed fluid layer and (ii) the macro-scale liquid meniscus thickness, curvature, and curvature gradient profiles. For our validation studies with commercial lenses, the apparatus is shown to measure thickness profiles within 4.1%-10.8% error.

  16. Single-shot readout of accumulation mode Si/SiGe spin qubits using RF reflectometry

    NASA Astrophysics Data System (ADS)

    Volk, Christian; Martins, Frederico; Malinowski, Filip; Marcus, Charles M.; Kuemmeth, Ferdinand

    Spin qubits based on gate-defined quantum dots are promising systems for realizing quantum computation. Due to their low concentration of nuclear-spin-carrying isotopes, Si/SiGe heterostructures are of particular interest. While high fidelities have been reported for single-qubit and two-qubit gate operations, qubit initialization and measurement times are relatively slow. In order to develop fast read-out techniques compatible with the operation of spin qubits, we characterize double and triple quantum dots confined in undoped Si/Si0.7Ge0.3 heterostructures using accumulation and depletion gates and a nearby RF charge sensor dot. We implement a RF reflectometry technique that allows single-shot charge read-out at integration times on the order of a few μs. We show our recent advancement towards implementing spin qubits in these structures, including spin-selective single-shot read-out.

  17. Reflectometry diagnostics on TCV

    NASA Astrophysics Data System (ADS)

    Molina Cabrera, Pedro; Coda, Stefano; Porte, Laurie; Offeddu, Nicola; Tcv Team

    2017-10-01

    Both profile reflectometer and Doppler back-scattering (DBS) diagnostics are being developed for the TCV Tokamak using a steerable quasi-optical launcher and universal polarizers. First results will be presented. A pulse reflectometer is being developed to complement Thomson Scattering measurements of electron density, greatly increasing temporal resolution and also effectively enabling fluctuation measurements. Pulse reflectometry consists of sending short pulses of varying frequency and measuring the roundtrip group-delay with precise chronometers. A fast arbitrary waveform generator is used as a pulse source feeding frequency multipliers that bring the pulses to V-band. A DBS diagnostic is currently operational in TCV. DBS may be used to infer the perpendicular velocity and wave number spectrum of electron density fluctuations in the 3-15 cm-1 wave-number range. Off-the-shelf transceiver modules, originally used for VNA measurements, are being used in a Doppler radar configuration. See author list of S. Coda et al., 2017 Nucl. Fusion 57 102011.

  18. Neural network evaluation of reflectometry density profiles for control purposes

    NASA Astrophysics Data System (ADS)

    Santos, J.; Nunes, F.; Manso, M.; Nunes, I.

    1999-01-01

    Broadband reflectometry is a diagnostic that is able to measure the density profile with high spatial and temporal resolutions, therefore it can be used to improve the performance of advanced tokamak operation modes and to supplement or correct the magnetics for plasma position control. To perform these tasks real-time processing is needed. Here we present a method that uses a neural network to make a fast evaluation of radial positions for selected density layers. Typical ASDEX Upgrade density profiles were used to generate the simulated network training and test sets. It is shown that the method has the potential to meet the tight timing requirements of control applications with the required accuracy. The network is also able to provide an accurate estimation of the position of density layers below the first density layer which is probed by an O-mode reflectometer, provided that it is trained with a realistic density profile model.

  19. Measuring optical fiber length by use of a short-pulse optical fiber ring laser in a self-injection seeding scheme.

    PubMed

    Wang, Yi-Ping; Wang, Dong Ning; Jin, Wei

    2006-09-01

    A method for measuring the length of an optical fiber by use of an optical fiber ring laser pulse source is proposed and demonstrated. The key element of the optical fiber ring laser is a gain-switched Fabry-Perot laser diode operated in a self-injection seeding scheme. This method is especially suitable for measuring a medium or long fiber, and a resolution of 0.1 m is experimentally achieved. The measurement is implemented by accurately determining the pulse frequency that can maximize the output power of the fiber ring laser. The measurement results depend only on the refractive index of the fiber corresponding to this single wavelength, instead of the group index of the fiber, which represents a great advantage over both optical time-domain reflectometry and optical low-coherence reflectometry methods.

  20. Verification of three-microphone impedance tube method for measurement of transmission loss in aerogels

    NASA Astrophysics Data System (ADS)

    Connick, Robert J.

    Accurate measurement of normal incident transmission loss is essential for the acoustic characterization of building materials. In this research, a method of measuring normal incidence sound transmission loss proposed by Salissou et al. as a complement to standard E2611-09 of the American Society for Testing and Materials [Standard Test Method for Measurement of Normal Incidence Sound Transmission of Acoustical Materials Based on the Transfer Matrix Method (American Society for Testing and Materials, New York, 2009)] is verified. Two sam- ples from the original literature are used to verify the method as well as a Filtros RTM sample. Following the verification, several nano-material Aerogel samples are measured.

  1. Microwave Absorption Properties of Co@C Nanofiber Composite for Normal and Oblique Incidence

    NASA Astrophysics Data System (ADS)

    Zhang, Junming; Wang, Peng; Chen, Yuanwei; Wang, Guowu; Wang, Dian; Qiao, Liang; Wang, Tao; Li, Fashen

    2018-05-01

    Co@C nanofibers have been prepared by an electrospinning technique. Uniform morphology of the nanofibers and good dispersion of the magnetic cobalt nanoparticles in the carbon fiber frame were confirmed by field-emission scanning electron microscopy and high-resolution transmission electron microscopy. The electromagnetic parameters of a composite absorber composed of Co@C nanofibers/paraffin were measured from 2 GHz to 15 GHz. The electromagnetic wave absorption properties were simulated and investigated in the case of normal and oblique incidence. In the normal case, the absorber achieved absorption performance of - 40 dB at 7.1 GHz. When the angle of incidence was increased to 60°, the absorption effect with reflection loss (RL) exceeding - 10 dB could still be obtained. These results demonstrate that the reported Co@C nanofiber absorber exhibits excellent absorption performance over a wide range of angle of incidence.

  2. Solid state laser disk amplifer architecture: the normal-incidence stack

    DOEpatents

    Dane, C. Brent; Albrecht, Georg F.; Rotter, Mark D.

    2005-01-25

    Normal incidence stack architecture coupled with the development of diode array pumping enables the power/energy per disk to be increased, a reduction in beam distortions by orders of magnitude, a beam propagation no longer restricted to only one direction of polarization, and the laser becomes so much more amendable to robust packaging.

  3. Effect of Intrafix® SafeSet infusion apparatus on phlebitis in a neurological intensive care unit: a case-control study.

    PubMed

    Liu, F; Chen, D; Liao, Y; Diao, L; Liu, Y; Wu, M; Xue, X; You, C; Kang, Y

    2012-01-01

    To investigate the effect of the Intrafix(®) SafeSet infusion apparatus on the incidence of phlebitis in patients being intravenously infused in a neurological intensive care unit (ICU). Patients aged > 12 years, with no history of diabetes mellitus and no existing phlebitis, requiring a daily peripheral intravenous infusion of ≥ 8 h with the total period lasting ≥ 3 days, were enrolled. Infusions were performed using the Intrafix(®) SafeSet or normal infusion apparatus. Incidence of phlebitis (scored according to the Infusion Nursing Standards of Practice of the American Infusion Nurses Society) was analysed. Patients (n = 1545) were allocated to Intrafix(®) SafeSet (n = 709) or normal infusion (n = 836) groups, matched for age, gender and preliminary diagnosis. Incidence of phlebitis was significantly higher using normal infusion apparatus compared with the Intrafix(®) SafeSet (23.4% versus 17.9%, respectively). Intrafix(®) SafeSet infusion apparatus significantly reduced the incidence of phlebitis in patients in the neurological ICU, compared with normal infusion apparatus, and may be suitable for use in routine clinical practice.

  4. Field evaluations of "ShapeAccelArray" in-place MEMS inclinometer strings for subsurface deformation monitoring.

    DOT National Transportation Integrated Search

    2012-03-01

    Continuous monitoring of subsurface ground movements is accomplished with in-place instruments utilizing automated data acquisition methods. These typically include TDR (Time Domain Reflectometry) or assemblies of several servo-accelerometer-based, e...

  5. Long term pavement performance computed parameter : moisture content

    DOT National Transportation Integrated Search

    2008-01-01

    A study was conducted to compute in situ soil parameters based on time domain reflectometry (TDR) traces obtained from Long Term Pavement Performance (LTPP) test sections instrumented for the seasonal monitoring program (SMP). Ten TDR sensors were in...

  6. Assessment of NDE for key indicators of aging cables in nuclear power plants - Interim status

    NASA Astrophysics Data System (ADS)

    Glass, S. W.; Ramuhalli, P.; Fifield, L. S.; Prowant, M. S.; Dib, G.; Tedeschi, J. R.; Suter, J. D.; Jones, A. M.; Good, M. S.; Pardini, A. F.; Hartman, T. S.

    2016-02-01

    Degradation of the cable jacket, electrical insulation, and other cable components of installed cables within nuclear power plants (NPPs) is known to occur as a function of age, temperature, radiation, and other environmental factors. System tests verify cable function under normal loads; however, the concern is over cable performance under exceptional loads associated with design-basis events (DBEs). The cable's ability to perform safely over the initial 40-year planned and licensed life has generally been demonstrated and there have been very few age-related cable failures. With greater than 1000 km of power, control, instrumentation, and other cables typically found in an NPP, replacing all the cables would be a severe cost burden. Justification for life extension to 60 and 80 years requires a cable aging management program to justify cable performance under normal operation as well as accident conditions. Currently the gold standard for determining cable insulation degradation is the elongation-at-break (EAB). This, however, is an ex-situ measurement and requires removal of a sample for laboratory investigation. A reliable nondestructive examination (NDE) in-situ approach is desirable to objectively determine the suitability of the cable for service. A variety of tests are available to assess various aspects of electrical and mechanical cable performance, but none of these tests are suitable for all cable configurations nor does any single test confirm all features of interest. Nevertheless, the complete collection of test possibilities offers a powerful range of tools to assure the integrity of critical cables. Licensees and regulators have settled on a practical program to justify continued operation based on condition monitoring of a lead sample set of cables where test data is tracked in a database and the required test data are continually adjusted based on plant and fleet-wide experience. As part of the Light Water Reactor Sustainability program sponsored by the U.S. Nuclear Regulatory Commission, the U.S. Department of Energy, and industry (represented by the Electric Power Research Institute), an assessment of cable NDE methods was commissioned. Technologies include both bulk electrical measurements (Tan δ, time domain reflectometry, frequency domain reflectometry (FDR), partial discharge, and other techniques) and local insulation measurement (indenter, dynamic mechanical analysis interdigital capacitance, infrared spectral measurement, etc.). This aging cable NDE program update reviews the full range of techniques but focuses on the most interesting test approaches that have a chance to be deployed in-situ, particularly including Tan δ, FDR, and ultrasound methods that have been reviewed most completely in this progress period.

  7. Normalization of Testosterone Levels After Testosterone Replacement Therapy Is Associated With Decreased Incidence of Atrial Fibrillation.

    PubMed

    Sharma, Rishi; Oni, Olurinde A; Gupta, Kamal; Sharma, Mukut; Sharma, Ram; Singh, Vikas; Parashara, Deepak; Kamalakar, Surineni; Dawn, Buddhadeb; Chen, Guoqing; Ambrose, John A; Barua, Rajat S

    2017-05-09

    Atrial fibrillation (AF) is the most common cardiac dysrhythmia associated with significant morbidity and mortality. Several small studies have reported that low serum total testosterone (TT) levels were associated with a higher incidence of AF. In contrast, it is also reported that anabolic steroid use is associated with an increase in the risk of AF. To date, no study has explored the effect of testosterone normalization on new incidence of AF after testosterone replacement therapy (TRT) in patients with low testosterone. Using data from the Veterans Administrations Corporate Data Warehouse, we identified a national cohort of 76 639 veterans with low TT levels and divided them into 3 groups. Group 1 had TRT resulting in normalization of TT levels (normalized TRT), group 2 had TRT without normalization of TT levels (nonnormalized TRT), and group 3 did not receive TRT (no TRT). Propensity score-weighted stabilized inverse probability of treatment weighting Cox proportional hazard methods were used for analysis of the data from these groups to determine the association between post-TRT levels of TT and the incidence of AF. Group 1 (40 856 patients, median age 66 years) had significantly lower risk of AF than group 2 (23 939 patients, median age 65 years; hazard ratio 0.90, 95% CI 0.81-0.99, P =0.0255) and group 3 (11 853 patients, median age 67 years; hazard ratio 0.79, 95% CI 0.70-0.89, P =0.0001). There was no statistical difference between groups 2 and 3 (hazard ratio 0.89, 95% CI 0.78- 1.0009, P =0.0675) in incidence of AF. These novel results suggest that normalization of TT levels after TRT is associated with a significant decrease in the incidence of AF. © 2017 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.

  8. [Reference ranges of gestational weight gain in Chinese population on the incidence of macrosomia: a multi-center cross-sectional survey].

    PubMed

    Liang, H; Zhang, W Y; Li, X T

    2017-03-25

    Objective: To investigate the influence of gestational weight gain (GWG) on the incidence of macrosomia, and to establish the reference ranges of GWG based on the incidence of macrosomia. Methods: A multicenter, cross-sectional study was conducted. Totally, 112 485 women were recruited from 39 hospitals in 14 provinces in China. Totally, 61 149 cases were eligible with singleton pregnancies and non-premature deliveries. The associations of pre-pregnancy body mass index (BMI), GWG, newborn gender and gestational diabetes with macrosomia were analyzed with logistic regression. The normal GWG ranges were calculated in all maternal BMI subgroups, based on the normal incidence of macrosomia was set as the range of 5.0% to 10.0%. Results: In this study, the incidence of macrosomia was 7.46% (4 563/611 149). The macrosociam was positive related with maternal height, delivery week, pre-pregnancy BMI, GWG, gestational diabetes, primipara, and male babies significantly ( P< 0.05), based on unadjusted and adjusted logestic regression. The normal range of GWG 20.0-25.0, 10.0-20.0, 0-10.0 and 0-5.0 kg in subgroups of underweight (pre-pregnancy BMI<18.5 kg/m(2)), normal (18.5-24.9 kg/m(2)), overweight (25.0-29.9 kg/m(2)) and obese (≥30.0 kg/m(2)), respectively. Conclusion: The reference range of GWG in China based on the incidence of macrosomia is established.

  9. The differences in the incidence of diabetes mellitus and prediabetes according to the type of HMG-CoA reductase inhibitors prescribed in Korean patients.

    PubMed

    Kim, Tong Min; Kim, Hyunah; Jeong, Yoo Jin; Baik, Sun Jung; Yang, So Jung; Lee, Seung-Hwan; Cho, Jae-Hyoung; Lee, Hyunyong; Yim, Hyeon Woo; Choi, In Young; Yoon, Kun-Ho; Kim, Hun-Sung

    2017-10-01

    Very few studies conducted in Korea have investigated the relationship between statins and the incidence of diabetes. Therefore, we analyzed the progression from normal blood glucose to prediabetes and then to diabetes mellitus (DM) according to the type, intensity, and dose of statin prescribed. Data of patients who were first prescribed statins between 2009 and 2011 were extracted from electronic medical records. Patients with normal blood glucose or prediabetes were observed for 4 years after initiation of statin therapy. A total of 2890 patients were included in our study and analyzed on the basis of the first statin they were prescribed. The incidence rate of DM in patients with prediabetes was 1.72 times that of patients with normal glucose levels (odds ratio = 1.72, 95% confidence interval = 1.41-2.10, P < .001). Regarding progression from normal blood glucose to prediabetes, the incidence rate of prediabetes was significantly lower in patients prescribed pitavastatin (odds ratio = 0.62, 95% confidence interval = 0.40-0.96, P = .031) compared to that in patients prescribed atorvastatin. Regarding the progression from normal blood glucose or prediabetes to DM, there were no significant differences among all statins. Lower DM incidence in patients prescribed pitavastatin appears to be primarily because of the lower rate of progression from normal blood glucose to prediabetes. These findings indicate that avoiding statins because of DM risk is unjustified and that clinicians should prescribe statins from the appropriate potency group. Copyright © 2017 John Wiley & Sons, Ltd.

  10. Grating angle magnification enhanced angular sensor and scanner

    NASA Technical Reports Server (NTRS)

    Sun, Ke-Xun (Inventor); Byer, Robert L. (Inventor)

    2009-01-01

    An angular magnification effect of diffraction is exploited to provide improved sensing and scanning. This effect is most pronounced for a normal or near-normal incidence angle in combination with a grazing diffraction angle, so such configurations are preferred. Angular sensitivity can be further enhanced because the width of the diffracted beam can be substantially less than the width of the incident beam. Normal incidence configurations with two symmetric diffracted beams are preferred, since rotation and vertical displacement can be readily distinguished. Increased sensitivity to vertical displacement can be provided by incorporating an interferometer into the measurement system. Quad cell detectors can be employed to provide sensitivity to rotation about the grating surface normal. A 2-D grating can be employed to provide sensitivity to angular displacements in two different planes (e.g., pitch and yaw). Combined systems can provide sensitivity to vertical displacement and to all three angular degrees of freedom.

  11. Pelvic incidence variation among individuals: functional influence versus genetic determinism.

    PubMed

    Chen, Hong-Fang; Zhao, Chang-Qing

    2018-03-20

    Pelvic incidence has become one of the most important sagittal parameters in spinal surgery. Despite its great importance, pelvic incidence can vary from 33° to 85° in the normal population. The reasons for this great variability in pelvic incidence remain unexplored. The objective of this article is to present some possible interpretations for the great variability in pelvic incidence under both normal and pathological conditions and to further understand the determinants of pelvic incidence from the perspective of the functional requirements for bipedalism and genetic backgrounds via a literature review. We postulate that both pelvic incidence and pelvic morphology may be genetically predetermined, and a great variability in pelvic incidence may already exist even before birth. This great variability may also serve as a further reminder that the sagittal profile, bipedal locomotion mode, and genetic background of every individual are unique and specific, and clinicians should avoid making universally applying broad generalizations of pelvic incidence. Although PI is an important parameter and there are many theories behind its variability, we still do not have clear mechanistic answers.

  12. A normal incidence, high resolution X-ray telescope for solar coronal observations

    NASA Technical Reports Server (NTRS)

    Golub, L.

    1984-01-01

    A Normal Incidence high resolution X-ray Telescope is reported. The design of a telescope assembly which, after fabrication, will be integrated with the mirror fabrication process is described. The assembly is engineered to fit into the Black Brant rocket skin to survive sounding rocket launch conditions. A flight ready camera is modified and tested.

  13. Strong far-infrared intersubband absorption under normal incidence in heavily n-type doped nonalloy GaSb-AlSb superlattices

    NASA Technical Reports Server (NTRS)

    Samoska, L. A.; Brar, Berinder; Kroemer, H.

    1993-01-01

    We report on long-wavelength intersubband absorption under normal incidence in heavily doped binary-binary GaSb-AlSb superlattices. Due to a small energy difference between the ellipsoidal L valleys in GaSb and the low-density-of-states Gamma minimum, electrons spill over from the first Gamma subband into the higher-energy L subband in GaSb wells, where they are allowed to make an intersubband transition under normally incident radiation. A peak fractional absorption per quantum well of 6.8 x 10 exp 3 (absorption coefficient alpha of about 8500/cm) is observed at about 15 microns wavelength for a sheet concentration of 1.6 x 10 exp 12 sq cm/well.

  14. Associations among health behaviors, body mass index, hypertension, and diabetes mellitus: A path analysis.

    PubMed

    Min, Deulle; Cho, Eunhee

    2018-06-01

    Hypertension (HTN) and type 2 diabetes are common diseases; however, the effects of health behavior and body mass index (BMI) on their incidence and relationship are unclear. The purpose of this study was to investigate the associations among health behaviors, BMI, HTN, and type 2 diabetes.This study was a secondary data analysis using Korean Longitudinal Study of Aging data between 2010 and 2014 (third and fifth). The sample consisted of 3481 people aged 45 years or older. Path analysis was conducted using the generalized structural equation modeling of STATA 13.1 that enabled analyzing the types of binary variables and logit links.There were 129 underweight, 1714 normal, and 1638 overweight and obese individuals. In underweight and normal groups who had regular meals (B = 0.670, P < .001), BMI was higher. However, for those who were older (B = -0.041, P < .001) and female (B = -0.229, P = .021), BMI was lower. The incidence of HTN increased with age (B = 0.038, P = .001). In addition, the incidence of type 2 diabetes increased with age (B = 0.051, P = .005) and smoking (B = 1.539, P = .001). However, the incidence of type 2 diabetes was lower (B = -1.077, P = .036) for those who had regular meals. In the normal and overweight groups, BMI decreased with age (B = -0.033, P < .001). The incidence of HTN increased with age (B = 0.042, P < .001) and BMI (B = 0.145, P < .001). Moreover, the incidence of type 2 diabetes increased with age (B = 0.046, P < .001), smoking (B = 0.682, P = .020), and higher BMI (B = 0.151, P = .001).In the underweight and normal group, health behaviors were related to BMI. In the normal and overweight group, health behaviors were not related to BMI, but high BMI was related to the incidence of HTN and type 2 diabetes. Smoking has a direct effect on the incidence of type 2 diabetes. Thus, the importance of maintaining an ideal BMI and smoking cessation are highlighted.

  15. 77 FR 32006 - Special Conditions: Gulfstream Model GVI Airplane; High Incidence Protection

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-31

    ... Special Conditions No. 25-423-SC] Special Conditions: Gulfstream Model GVI Airplane; High Incidence... pertaining to a high incidence protection system that replaces the stall warning system during normal... V SR and not greater than 1.3 V SR . (6) The high incidence protection function disabled, or...

  16. Combined evaluation of grazing incidence X-ray fluorescence and X-ray reflectivity data for improved profiling of ultra-shallow depth distributions☆

    PubMed Central

    Ingerle, D.; Meirer, F.; Pepponi, G.; Demenev, E.; Giubertoni, D.; Wobrauschek, P.; Streli, C.

    2014-01-01

    The continuous downscaling of the process size for semiconductor devices pushes the junction depths and consequentially the implantation depths to the top few nanometers of the Si substrate. This motivates the need for sensitive methods capable of analyzing dopant distribution, total dose and possible impurities. X-ray techniques utilizing the external reflection of X-rays are very surface sensitive, hence providing a non-destructive tool for process analysis and control. X-ray reflectometry (XRR) is an established technique for the characterization of single- and multi-layered thin film structures with layer thicknesses in the nanometer range. XRR spectra are acquired by varying the incident angle in the grazing incidence regime while measuring the specular reflected X-ray beam. The shape of the resulting angle-dependent curve is correlated to changes of the electron density in the sample, but does not provide direct information on the presence or distribution of chemical elements in the sample. Grazing Incidence XRF (GIXRF) measures the X-ray fluorescence induced by an X-ray beam incident under grazing angles. The resulting angle dependent intensity curves are correlated to the depth distribution and mass density of the elements in the sample. GIXRF provides information on contaminations, total implanted dose and to some extent on the depth of the dopant distribution, but is ambiguous with regard to the exact distribution function. Both techniques use similar measurement procedures and data evaluation strategies, i.e. optimization of a sample model by fitting measured and calculated angle curves. Moreover, the applied sample models can be derived from the same physical properties, like atomic scattering/form factors and elemental concentrations; a simultaneous analysis is therefore a straightforward approach. This combined analysis in turn reduces the uncertainties of the individual techniques, allowing a determination of dose and depth profile of the implanted elements with drastically increased confidence level. Silicon wafers implanted with Arsenic at different implantation energies were measured by XRR and GIXRF using a combined, simultaneous measurement and data evaluation procedure. The data were processed using a self-developed software package (JGIXA), designed for simultaneous fitting of GIXRF and XRR data. The results were compared with depth profiles obtained by Secondary Ion Mass Spectrometry (SIMS). PMID:25202165

  17. LabVIEW interface with Tango control system for a multi-technique X-ray spectrometry IAEA beamline end-station at Elettra Sincrotrone Trieste

    NASA Astrophysics Data System (ADS)

    Wrobel, P. M.; Bogovac, M.; Sghaier, H.; Leani, J. J.; Migliori, A.; Padilla-Alvarez, R.; Czyzycki, M.; Osan, J.; Kaiser, R. B.; Karydas, A. G.

    2016-10-01

    A new synchrotron beamline end-station for multipurpose X-ray spectrometry applications has been recently commissioned and it is currently accessible by end-users at the XRF beamline of Elettra Sincrotrone Trieste. The end-station consists of an ultra-high vacuum chamber that includes as main instrument a seven-axis motorized manipulator for sample and detectors positioning, different kinds of X-ray detectors and optical cameras. The beamline end-station allows performing measurements in different X-ray spectrometry techniques such as Microscopic X-Ray Fluorescence analysis (μXRF), Total Reflection X-Ray Fluorescence analysis (TXRF), Grazing Incidence/Exit X-Ray Fluorescence analysis (GI-XRF/GE-XRF), X-Ray Reflectometry (XRR), and X-Ray Absorption Spectroscopy (XAS). A LabVIEW Graphical User Interface (GUI) bound with Tango control system consisted of many custom made software modules is utilized as a user-friendly tool for control of the entire end-station hardware components. The present work describes this advanced Tango and LabVIEW software platform that utilizes in an optimal synergistic manner the merits and functionality of these well-established programming and equipment control tools.

  18. Deposition and characterization of titania-silica optical multilayers by asymmetric bipolar pulsed dc sputtering of oxide targets

    NASA Astrophysics Data System (ADS)

    Sagdeo, P. R.; Shinde, D. D.; Misal, J. S.; Kamble, N. M.; Tokas, R. B.; Biswas, A.; Poswal, A. K.; Thakur, S.; Bhattacharyya, D.; Sahoo, N. K.; Sabharwal, S. C.

    2010-02-01

    Titania-silica (TiO2/SiO2) optical multilayer structures have been conventionally deposited by reactive sputtering of metallic targets. In order to overcome the problems of arcing, target poisoning and low deposition rates encountered there, the application of oxide targets was investigated in this work with asymmetric bipolar pulsed dc magnetron sputtering. In order to evaluate the usefulness of this deposition methodology, an electric field optimized Fabry Perot mirror for He-Cd laser (λ = 441.6 nm) spectroscopy was deposited and characterized. For comparison, this mirror was also deposited by the reactive electron beam (EB) evaporation technique. The mirrors developed by the two complementary techniques were investigated for their microstructural and optical reflection properties invoking atomic force microscopy, ellipsometry, grazing incidence reflectometry and spectrophotometry. From these measurements the layer geometry, optical constants, mass density, topography, surface and interface roughness and disorder parameters were evaluated. The microstructural properties and spectral functional characteristics of the pulsed dc sputtered multilayer mirror were found to be distinctively superior to the EB deposited mirror. The knowledge gathered during this study has been utilized to develop a 21-layer high-pass edge filter for radio photoluminescence dosimetry.

  19. Ultrasound-aided high-resolution biophotonic imaging

    NASA Astrophysics Data System (ADS)

    Wang, Lihong V.

    2003-10-01

    We develop novel biophotonic imaging for early-cancer detection, a grand challenge in cancer research, using nonionizing electromagnetic and ultrasonic waves. Unlike ionizing x-ray radiation, nonionizing electromagnetic waves such as optical waves are safe for biomedical applications and reveal new contrast mechanisms and functional information. For example, our spectroscopic oblique-incidence reflectometry can detect skin cancers based on functional hemoglobin parameters and cell nuclear size with 95% accuracy. Unfortunately, electromagnetic waves in the nonionizing spectral region do not penetrate biological tissue in straight paths as do x-rays. Consequently, high-resolution tomography based on nonionizing electromagnetic waves alone, as demonstrated by our Mueller optical coherence tomography, is limited to superficial tissue imaging. Ultrasonic imaging, on the contrary, furnishes good imaging resolution but has poor contrast in early-stage tumors and has strong speckle artifacts as well. We developed ultrasound-mediated imaging modalities by combining electromagnetic and ultrasonic waves synergistically. The hybrid modalities yield speckle-free electromagnetic-contrast at ultrasonic resolution in relatively large biological tissue. In ultrasound-modulated (acousto)-optical tomography, a focused ultrasonic wave encodes diffuse laser light in scattering biological tissue. In photo-acoustic (thermo-acoustic) tomography, a low-energy laser (RF) pulse induces ultrasonic waves in biological tissue due to thermoelastic expansion.

  20. Lunar Crustal Magnetism: Correlations with Geology

    NASA Technical Reports Server (NTRS)

    Halekas, J. S.; Mitchell, D. L.; Lin, R. P.; Frey, S.; Acuna, M. H.; Hood, L. L.; Binder, A. B.

    2001-01-01

    With Lunar Prospector reflectometry data we now have sufficient surface coverage to allow detailed comparisons between crustal magnetism and geology. We find substantial evidence that lunar magnetism is dominated by the effects of impact processes. Additional information is contained in the original extended abstract.

  1. A reevaluation of TDR propagation time determination in soils and geological media

    USDA-ARS?s Scientific Manuscript database

    Time domain reflectometry (TDR) is an established method for the determination of apparent dielectric permittivity and water content in soils. Using current waveform interpretation procedures, signal attenuation and variation in dielectric media properties along the transmission line can significant...

  2. Building professional capacity in ITS : guidelines on developing the future professional

    DOT National Transportation Integrated Search

    1999-07-01

    Time domain reflectometry (TDR) has become one of the most reliable methods for measuring in-situ soil moisture content. TDR sensors developed by the Federal Highway Administration (FHWA) are being used in the Long-Term Pavement Performance (LTPP) Se...

  3. Analysis of time domain reflectometry data from LTPP seasonal monitoring program test sections

    DOT National Transportation Integrated Search

    1996-07-01

    This report documents an approach for designing an Advanced Traffic Management System (ATMS) from a human factors perspective. In designing the ATMS from a human factors perspective, a user-centered top-down system analysis was conducted. Methodologi...

  4. Normal and Tangential Momentum Accommodation for Earth Satellite Conditions

    NASA Technical Reports Server (NTRS)

    Knechtel, Earl D.; Pitts, William C.

    1973-01-01

    Momentum accommodation was determined experimentally for gas-surface interactions simulating in a practical way those of near-earth satellites. Throughout the ranges of gas energies and incidence angles of interest for earth-conditions, two components of force were measured by means of a vacuum microbalance to determine the normal and tangential momentum-accommodation coefficients for nitrogen ions on technical-quality aluminum surfaces. For these experimental conditions, the electrodynamics of ion neutralization near the surface indicate that results for nitrogen ions should differ relatively little from those for nitrogen molecules, which comprise the largest component of momentum flux for near-earth satellites. The experimental results indicated that both normal and tangential momentum-accommodation coefficients varied widely with energy, tending to be relatively well accommodated at the higher energies, but becoming progressively less accommodated as the energy was reduced to and below that for earth-satellite speeds. Both coefficients also varied greatly with incidence angle, the normal momentum becoming less accommodated as the incidence angle became more glancing, whereas the tangential momentum generally became more fully accommodated. For each momentum coefficient, an empirical correlation function was obtained which closely approximated the experimental results over the ranges of energy and incidence angle. Most of the observed variations of momentum accommodation with energy and incidence angle were qualitatively indicated by a calculation using a three-dimensional model that simulated the target surface by a one-dimensional attractive potential and hard sphere reflectors.

  5. The Effect of Detonation Wave Incidence Angle on the Acceleration of Flyers by Explosives Heavily Laden with Inert Additives

    NASA Astrophysics Data System (ADS)

    Loiseau, Jason; Georges, William; Frost, David; Higgins, Andrew

    2015-06-01

    The incidence angle of a detonation wave is often assumed to weakly influence the terminal velocity of an explosively driven flyer. For explosives heavily loaded with dense additives, this may not be true due to differences in momentum and energy transfer between detonation products, additive particles, and the flyer. For tangential incidence the particles are first accelerated against the flyer via an expansion fan, whereas they are first accelerated by the detonation wave in the normal case. In the current study we evaluate the effect of normal versus tangential incidence on the acceleration of flyers by nitromethane heavily loaded with a variety of additives. Normal detonation was initiated via an explosively driven slapper. Flyer acceleration was measured with heterodyne laser interferometry (PDV). The influence of wave angle is evaluated by comparing the terminal velocity in the two cases (i.e., normal and grazing) for the heavily loaded mixtures. The decrement in flyer velocity correlated primarily with additive volume fraction and had a weak dependence on additive density or particle size. The Gurney energy of the heterogeneous explosive was observed to increase with flyer mass, presumably due to the timescale over which impinging particles could transfer momentum.

  6. The influence of breed and sex on the incidence of mortalities and skin tears in broiler carcasses.

    PubMed

    Casey, N H; Smith, G A; Crosley, R I

    1989-06-01

    The effects of nutrition, breed and sex on the incidence of mortalities and of skin tears on broiler carcasses were studied. Both sexes of 2 breeds, Hubbard and Ross, were given 4 dietary treatments consisting of a normal level of vitamin and mineral premix plus 300 ppm furazolidone, twice normal premix inclusion level plus 300 ppm furazolidone, a normal level of vitamin and mineral premix, and twice normal mineral premix inclusion level. A coccidiostat containing the active ingredient halofuginone was included at 6 ppm, twice the recommended dosage. Starter, grower and finisher diets were fed respectively up to Day 20, Day 30 and Day 48. Group growth performances, mortalities and the incidence of torn skin were monitored on both the live birds and carcasses. The effect of the different nutritional treatments on skin tears was not significant (P = 0.9533), as was the breed effect (P = 0.0547). However, the effect of sex was significant (P = 0.0044), the incidence in hens being higher. Mortalities among the Hubbard were significantly greater than among the Ross (P = 0.0001). Hens showed a slightly higher mortality rate than roosters, tending towards significance at the 5% level (P = 0.0554).

  7. Early Stages of Oxidative Stress-Induced Membrane Permeabilization: A Neutron Reflectometry Study

    PubMed Central

    Smith, Hillary L.; Howland, Michael C.; Szmodis, Alan W.; Li, Qijuan; Daemen, Luke L.; Parikh, Atul N.; Majewski, Jaroslaw

    2009-01-01

    Neutron reflectometry was used to probe in situ the structure of supported lipid bilayers at the solid–liquid interface during the early stages of UV-induced oxidative degradation. Single-component supported lipid bilayers composed of gel phase, dipalmitoyl-sn-glycero-3-phosphocholine (DPPC), and fluid phase, 1-palmitoyl-2-oleoyl-sn-glycero-3-phosphocholine (POPC), phospholipids were exposed to low-dose oxidative stress generated by UV light and their structures were examined by neutron reflectometry. An interrupted illumination mode, involving exposures in 15 min increments with 2 h intervals between subsequent exposures, and a continuous mode involving a single 60 (or 90) min exposure period were employed. In both cases, pronounced differences in the structure of the lipid bilayer after exposure were observed. Interrupted exposure led to a substantial decrease in membrane coverage but preserved its total thickness at reduced scattering length densities. These results indicate that the initial phase during UV-induced membrane degradation involves the formation of hydrophilic channels within the membrane. This is consistent with the loss of some lipid molecules we observe and attendant reorganization of residual lipids forming hemimicellar edges of the hydrophilic channels. In contrast, continuous illumination produced a graded interface of continuously varied scattering length density (and hence hydrocarbon density) extending 100–150 Å into the liquid phase. Exposure of a DPPC bilayer to UV light in the presence of a reservoir of unfused vesicles showed low net membrane disintegration during oxidative stress, presumably because of surface back-filling from the bulk reservoir. Chemical evidence for membrane degradation was obtained by mass spectrometry and Fourier transform infrared spectroscopy. Further evidence for the formation of hydrophilic channels was furnished by fluorescence microscopy and imaging ellipsometry data. PMID:19275260

  8. Density fluctuation correlation measurements in ASDEX Upgrade using poloidal and radial correlation reflectometry

    NASA Astrophysics Data System (ADS)

    Prisiazhniuk, D.; Conway, G. D.; Krämer-Flecken, A.; Stroth, U.; the ASDEX Upgrade Team

    2018-07-01

    The poloidal correlation reflectometry diagnostic operated in ordinary mode with additional radial correlation channel is applied in this paper to investigate the correlation of the turbulent density fluctuations. The perpendicular and radial correlation lengths, l ⊥ and l r , the perpendicular velocity v⊥ and the dissipation (mutation) time τ d are measured simultaneously from the outer core to edge in the L-mode plasmas of ASDEX Upgrade. It is shown that in the outer core region (0.6 < ρ pol < 0.9) the measured correlation lengths scale with the drift wave length, l ⊥ ≈ 5ρ s and l r ≈ 10ρ s , while the dissipation time is inversely correlated with the velocity τ d ≈ 40/v ⊥(τ d is in μs and v ⊥ in km s–1). In the pedestal region (0.925 < ρ pol < 0.98), where the E × B shear flows are present, a loss of measured correlation is observed which can be explained by a combination of small propagation velocity and an additional reduction of τ d . In the E r well region (ρ pol ≈ 0.99), the measured perpendicular correlation length increases {l}\\perp ≈ 13{ρ }s and the radial correlation length decreases l r ≈ 4ρ s compared to the outer core values. The correlation measurements are interpreted in the frame of the linear regime of reflectometry (applied only to ρ pol < 0.9). Using the Born approximation we show that the finite wavenumber sensitivity of the reflectometer increases the measured l ⊥and l r , but does not affect the measured τ d . By the including diagnostic correction the real correlation lengths l ⊥ ≈ l r ≈ 3ρ s are estimated.

  9. Multimodal ophthalmic imaging using handheld spectrally encoded coherence tomography and reflectometry (SECTR)

    NASA Astrophysics Data System (ADS)

    Leeburg, Kelsey C.; El-Haddad, Mohamed T.; Malone, Joseph D.; Terrones, Benjamin D.; Tao, Yuankai K.

    2018-02-01

    Scanning laser ophthalmoscopy (SLO) provides high-speed, noninvasive en face imaging of the retinal fundus. Optical coherence tomography (OCT) is the current "gold-standard" for ophthalmic diagnostic imaging and enables depth-resolved visualization of ophthalmic structures and image-based surrogate biomarkers of disease. We present a compact optical and mechanical design for handheld spectrally encoded coherence tomography and reflectometry (SECTR) for multimodality en face spectrally encoded reflectometry (SER) and cross-sectional OCT imaging. We custom-designed a double-pass telecentric scan lens, which halves the size of 4-f optical relays and allowed us to reduce the footprint of our SECTR scan-head by a factor of >2.7x (volume) over our previous design. The double-pass scan lens was optimized for diffraction-limited performance over a +/-10° scan field. SECTR optics and optomechanics were combined in a compact rapid-prototyped enclosure with dimensions 87 x 141.8 x 137 mm (w x h x d). SECTR was implemented using a custom-built 400 kHz 1050 nm swept-source. OCT and SER were simultaneously digitized on dual input channels of a 4 GS/s digitizer at 1.4 GS/s per channel. In vivo human en face SER and cross-sectional OCT images were acquired at 350 fps. OCT volumes of 1000 B-scans were acquired in 2.86 s. We believe clinical translation of our compact handheld design will benefit point-of-care ophthalmic diagnostics in patients who are unable to be imaged on conventional slit-lamp based systems, such as infants and the bedridden. When combined with multi-volumetric registration methods, handheld SECTR will have advantages in motion-artifact free imaging over existing handheld technologies.

  10. Advanced density profile reflectometry; the state-of-the-art and measurement prospects for ITER

    NASA Astrophysics Data System (ADS)

    Doyle, E. J.

    2006-10-01

    Dramatic progress in millimeter-wave technology has allowed the realization of a key goal for ITER diagnostics, the routine measurement of the plasma density profile from millimeter-wave radar (reflectometry) measurements. In reflectometry, the measured round-trip group delay of a probe beam reflected from a plasma cutoff is used to infer the density distribution in the plasma. Reflectometer systems implemented by UCLA on a number of devices employ frequency-modulated continuous-wave (FM-CW), ultrawide-bandwidth, high-resolution radar systems. One such system on DIII-D has routinely demonstrated measurements of the density profile over a range of electron density of 0-6.4x10^19,m-3, with ˜25 μs time and ˜4 mm radial resolution, meeting key ITER requirements. This progress in performance was made possible by multiple advances in the areas of millimeter-wave technology, novel measurement techniques, and improved understanding, including: (i) fast sweep, solid-state, wide bandwidth sources and power amplifiers, (ii) dual polarization measurements to expand the density range, (iii) adaptive radar-based data analysis with parallel processing on a Unix cluster, (iv) high memory depth data acquisition, and (v) advances in full wave code modeling. The benefits of advanced system performance will be illustrated using measurements from a wide range of phenomena, including ELM and fast-ion driven mode dynamics, L-H transition studies and plasma-wall interaction. The measurement capabilities demonstrated by these systems provide a design basis for the development of the main ITER profile reflectometer system. This talk will explore the extent to which these reflectometer system designs, results and experience can be translated to ITER, and will identify what new studies and experimental tests are essential.

  11. On the angular dependence of focused laser ablation by nanosecond pulses in solgel and polymer materials

    NASA Astrophysics Data System (ADS)

    George, D. S.; Onischenko, A.; Holmes, A. S.

    2004-03-01

    Focused laser ablation by single laser pulses at varying angles of incidence is studied in two materials of interest: a solgel (Ormocer 4) and a polymer (SU8). For a range of angles (up to 70° from normal), and for low-energy (<20 μJ), 40 ns pulses at 266 nm wavelength, the ablation depth along the direction of the incident laser beam is found to be independent of the angle of incidence. This allows the crater profiles at oblique incidence to be generated directly from the crater profiles at normal incidence by a simple coordinate transformation. This result is of use in the development of simulation tools for direct-write laser ablation. A simple model based on the moving ablation front approach is shown to be consistent with the observed behavior.

  12. Wavelet-Based Processing for Fiber Optic Sensing Systems

    NASA Technical Reports Server (NTRS)

    Hamory, Philip J. (Inventor); Parker, Allen R., Jr. (Inventor)

    2016-01-01

    The present invention is an improved method of processing conglomerate data. The method employs a Triband Wavelet Transform that decomposes and decimates the conglomerate signal to obtain a final result. The invention may be employed to improve performance of Optical Frequency Domain Reflectometry systems.

  13. Pilot study on rugged fiber optic brillouin sensors for large-strain measurements to ensure the safety of transportation structures.

    DOT National Transportation Integrated Search

    2012-07-01

    Brillouin-scattering Optical Time Domain Reflectometry (BOTDR) is a viable technology for simultaneous, distributed : strain and temperature measurements for miles-long transportation structures. It is a promising tool to ensure the smooth : operatio...

  14. Novel Use of Time Domain Reflectometry in Infiltration-based Low Impact Development Practices

    EPA Science Inventory

    Low impact development (LID) practices are structures that intercept stormwater runoff and infiltrate it through a range of media types, including aggregate, rain garden media, and underlying soils. Hydrologic performance is typically evaluated by comparing inlet and underdrain o...

  15. Phase-detected Brillouin optical correlation-domain reflectometry

    NASA Astrophysics Data System (ADS)

    Mizuno, Yosuke; Hayashi, Neisei; Fukuda, Hideyuki; Nakamura, Kentaro

    2018-05-01

    Optical fiber sensing techniques based on Brillouin scattering have been extensively studied for structural health monitoring owing to their capability of distributed strain and temperature measurement. Although a higher signal-to-noise ratio (leading to high spatial resolution and high-speed measurement) is generally obtained for two-end-access systems, they reduce the degree of freedom in embedding the sensors into structures, and render the measurement no longer feasible when extremely high loss or breakage occurs at a point of the sensing fiber. To overcome these drawbacks, a one-end-access sensing technique called Brillouin optical correlation-domain reflectometry (BOCDR) has been developed. BOCDR has a high spatial resolution and cost efficiency, but its conventional configuration suffered from relatively low-speed operation. In this paper, we review the recently developed high-speed configurations of BOCDR, including phase-detected BOCDR, with which we demonstrate real-time distributed measurement by tracking a propagating mechanical wave. We also demonstrate breakage detection with a wide strain dynamic range.

  16. Time-Domain Reflectometry for Tamper Indication in Unattended Monitoring Systems for Safeguards

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tedeschi, Jonathan R.; Smith, Leon E.; Moore, David E.

    2014-12-01

    The International Atomic Energy Agency (IAEA) continues to expand its use of unattended, remotely monitored measurement systems. An increasing number of systems and an expanding family of instruments create challenges in terms of deployment efficiency and the implementation of data authentication measures. Pacific Northwest National Laboratory (PNNL) leads a collaboration that is exploring various tamper-indicating (TI) measures that could help to address some of the long-standing detector and data-transmission authentication challenges with IAEA’s unattended systems. PNNL is investigating the viability of active time-domain reflectometry (TDR) along two parallel but interconnected paths: (1) swept-frequency TDR as the highly flexible, laboratory goldmore » standard to which field-deployable options can be compared, and (2) a low-cost commercially available spread-spectrum TDR technology as one option for field implementation. This report describes PNNL’s progress and preliminary findings from the first year of the study, and describes the path forward.« less

  17. Radio frequency reflectometry and charge sensing of a precision placed donor in silicon

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hile, Samuel J., E-mail: samhile@gmail.com; House, Matthew G.; Peretz, Eldad

    2015-08-31

    We compare charge transitions on a deterministic single P donor in silicon using radio frequency reflectometry measurements with a tunnel coupled reservoir and DC charge sensing using a capacitively coupled single electron transistor (SET). By measuring the conductance through the SET and comparing this with the phase shift of the reflected radio frequency (RF) excitation from the reservoir, we can discriminate between charge transfer within the SET channel and tunneling between the donor and reservoir. The RF measurement allows observation of donor electron transitions at every charge degeneracy point in contrast to the SET conductance signal where charge transitions aremore » only observed at triple points. The tunnel coupled reservoir has the advantage of a large effective lever arm (∼35%), allowing us to independently extract a neutral donor charging energy ∼62 ± 17 meV. These results demonstrate that we can replace three terminal transistors by a single terminal dispersive reservoir, promising for high bandwidth scalable donor control and readout.« less

  18. Microwave dielectric study of an oligomeric electrolyte gelator by time domain reflectometry.

    PubMed

    Kundu, Shyamal Kumar; Yagihara, Shin; Yoshida, Masaru; Shibayama, Mitsuhiro

    2009-07-30

    The dynamics of water molecules in aqueous solutions of an oligomeric electrolyte gelator, poly[pyridinium-1,4-diyliminocarbonyl-1,4-phenylene-methylene chloride] (1-Cl) was characterized by microwave dielectric measurements using the time domain reflectometry method. The dielectric dispersion and absorption curves related to the orientational motion of water molecules were described by the Cole-Cole equation. Discontinuities were observed in the concentration dependence of the dielectric relaxation strength, Deltaepsilonh, as well as in the Cole-Cole parameter, betah. These discontinuities were observed between the samples with concentrations of 6 and 7 g/L 1-Cl/water, which correspond to a change in the transparency. Such a discontinuity corresponds to the observation of the critical concentration of gelation. The interaction between water and 1-Cl molecules was discussed from the tauh-betah diagram. As 1-Cl carries an amide group, it could be expected that 1-Cl may interact hydrophilically with water, but the present result suggests that 1-Cl interact hydrophobically with water.

  19. Instrumentation techniques for monitoring shock and detonation waves

    NASA Astrophysics Data System (ADS)

    Dick, R. D.; Parrish, R. L.

    1985-09-01

    CORRTEX (Continuous Reflectometry for Radius Versus Time Experiments), SLIFER (Shorted Location Indication by Frequency of Electrical Resonance), and pin probes were used to monitor several conditions of blasting such as the detonation velocity of the explosive, the functioning of the stemming column confining the explosive, and rock mass motion. CORRTEX is a passive device that employs time-domain reflectometry to interrogate the two-way transit time of a coaxial cable. SLIFER is an active device that monitors the changing frequency resulting from a change in length of a coaxial cable forming an element of an oscillator circuit. Pin probes in this application consist of RG-174 coaxial cables, each with an open circuit, placed at several known locations within the material. Each cable is connected to a pulse-forming network and a voltage source. When the cables are shorted by the advancing wave, time-distance data are produced from which a velocity can be computed. Each technique, installation of the gauge, examples of the signals, and interpretation of the records are described.

  20. Phase-detected Brillouin optical correlation-domain reflectometry

    NASA Astrophysics Data System (ADS)

    Mizuno, Yosuke; Hayashi, Neisei; Fukuda, Hideyuki; Nakamura, Kentaro

    2018-06-01

    Optical fiber sensing techniques based on Brillouin scattering have been extensively studied for structural health monitoring owing to their capability of distributed strain and temperature measurement. Although a higher signal-to-noise ratio (leading to high spatial resolution and high-speed measurement) is generally obtained for two-end-access systems, they reduce the degree of freedom in embedding the sensors into structures, and render the measurement no longer feasible when extremely high loss or breakage occurs at a point of the sensing fiber. To overcome these drawbacks, a one-end-access sensing technique called Brillouin optical correlation-domain reflectometry (BOCDR) has been developed. BOCDR has a high spatial resolution and cost efficiency, but its conventional configuration suffered from relatively low-speed operation. In this paper, we review the recently developed high-speed configurations of BOCDR, including phase-detected BOCDR, with which we demonstrate real-time distributed measurement by tracking a propagating mechanical wave. We also demonstrate breakage detection with a wide strain dynamic range.

  1. Optimal design of reflectometer density profile measurements using a radar systems approach (invited) (abstract)

    NASA Astrophysics Data System (ADS)

    Doyle, E. J.; Kim, K. W.; Peebles, W. A.; Rhodes, T. L.

    1997-01-01

    Reflectometry is an attractive and versatile diagnostic technique that can address a wide range of measurement needs on fusion devices. However, progress in the area of profile measurement has been hampered by the lack of a well-understood basis for the optimum design and implementation of such systems. Such a design basis is provided by the realization that reflectometer systems utilized for density profile measurements are in fact specialized forms of radar systems. In this article five criteria are introduced by which reflectometer systems can be systematically designed for optimal performance: range resolution, spatial sampling, turbulence immunity, bandwidth optimization, and the need for adaptive data processing. Many of these criteria are familiar from radar systems analysis, and are applicable to reflectometry after allowance is made for differences stemming from the nature of the plasma target. These criteria are utilized to critically evaluate current reflectometer density profile techniques and indicate improvements that can impact current and next step devices, such as ITER.

  2. Distributed dynamic strain measurement using long-gauge FBG and DTR3 interrogator based on delayed transmission/reflection ratiometric reflectometry

    NASA Astrophysics Data System (ADS)

    Nishiyama, M.; Igawa, H.; Kasai, T.; Watanabe, N.

    2013-09-01

    In this paper, we reveal characteristics of static and dynamic distributed strain measurement using a long-gauge fiber Bragg grating (FBG) and a Delayed Transmission/Reflection Ratiometric Reflectometry (DTR3) scheme. The DTR3 scheme has capability of detecting distributed strain using the long-gauge FBG with 50-cm spatial resolution. Additionally, dynamic strain measurement can be achieved using this technique in 100-Hz sampling rate. We evaluated strain sensing characteristics of the long-gauge FBG attached on 2.5-m aluminum bar by a four-point bending equipment. Experimental results showed that the DTR3 using the long-gauge FBG could detect distributed strain in static tests and resonance frequency of structure in free vibration tests. As a result, it is suggested that the DTR3 scheme using the longgauge FBG is attractive to structural health monitoring (SHM) as dynamic deformation detection of a few and tensmeters structure such as the airplane wing and the helicopter blade.

  3. Implementation of the new multichannel X-mode edge density profile reflectometer for the ICRF antenna on ASDEX Upgrade

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Aguiam, D. E., E-mail: daguiam@ipfn.tecnico.ulisboa.pt; Silva, A.; Carvalho, P. J.

    A new multichannel frequency modulated continuous-wave reflectometry diagnostic has been successfully installed and commissioned on ASDEX Upgrade to measure the plasma edge electron density profile evolution in front of the Ion Cyclotron Range of Frequencies (ICRF) antenna. The design of the new three-strap ICRF antenna integrates ten pairs (sending and receiving) of microwave reflectometry antennas. The multichannel reflectometer can use three of these to measure the edge electron density profiles up to 2 × 10{sup 19} m{sup −3}, at different poloidal locations, allowing the direct study of the local plasma layers in front of the ICRF antenna. ICRF power coupling,more » operational effects, and poloidal variations of the plasma density profile can be consistently studied for the first time. In this work the diagnostic hardware architecture is described and the obtained density profile measurements were used to track outer radial plasma position and plasma shape.« less

  4. Frequency Domain Reflectometry Modeling and Measurement for Nondestructive Evaluation of Nuclear Power Plant Cables

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Glass, Samuel W.; Fifield, Leonard S.; Jones, Anthony M.

    Cable insulation polymers are among the more susceptible materials to age-related degradation within a nuclear power plant. This is recognized by both regulators and utilities, so all plants have developed cable aging management programs to detect damage before critical component failure in compliance with regulatory guidelines. Although a wide range of tools are available to evaluate cables and cable systems, cable aging management programs vary in how condition monitoring and NDE is conducted as utilities search for the most reliable and cost-effective ways to assess cable system condition. Frequency domain reflectometry (FDR) is emerging as one valuable tool to locatemore » and assess damaged portions of a cable system with minimal cost and only requires access in most cases to one of the cable terminal ends. This work examines a physics-based model of a cable system and relates it to FDR measurements for a better understanding of specific damage influences on defect detectability.« less

  5. Neutron Reflectometry and Small Angle Neutron Scattering of ABC Miktoarm Terpolymer Thin-Films

    NASA Astrophysics Data System (ADS)

    Arras, Matthias M. L.; Wang, Weiyu; Mahalik, Jyoti P.; Hong, Kunlun; Sumpter, Bobby G.; Smith, Gregory S.; Chernyy, Sergey; Kim, Hyeyoung; Russell, Thomas P.

    Due to the constraint of the junction point in miktoarm terpolymers, where three chains meet, ABC miktoarm terpolymers are promising to obtain nanostructured, long-range ordered materials. We present details of the thin-film structure of ABC miktoarm terpolymers in the poly(styrene), poly(isoprene), poly(2-vinylpyridine) (PS-PI-P2VP) system, investigated by neutron reflectometry and small angle neutron scattering. To this end, we synthesized partially deuterated versions of the PS-PI-P2VP and investigated annealed samples, spin-coated to various thicknesses of the bulk repeat period. Furthermore, we investigated the structural change upon selective blending with homopolymers or fullerenes. We find that thin-film constraints on the morphology can vanish after only twice the repetition period. In addition, it is indicated that nanoparticles improve the ordering in these systems, however, this seems to be not necessarily true for homopolymer blending. This research used resources at the Spallation Neutron Source, a DOE Office of Science User Facility operated by the Oak Ridge National Laboratory.

  6. Catheter guided by optical coherence domain reflectometry

    DOEpatents

    Everett, Matthew; Colston, Billy W.; Da Silva, Luiz B.; Matthews, Dennis

    2002-01-01

    A guidance and viewing system based on multiplexed optical coherence domain reflectometry is incorporated into a catheter, endoscope, or other medical device to measure the location, thickness, and structure of the arterial walls or other intra-cavity regions at discrete points on the medical device during minimally invasive medical procedures. The information will be used both to guide the device through the body and to evaluate the tissue through which the device is being passed. Multiple optical fibers are situated along the circumference of the device. Light from the distal end of each fiber is directed onto the interior cavity walls via small diameter optics (such as gradient index lenses and mirrored corner cubes). Both forward viewing and side viewing fibers can be included. The light reflected or scattered from the cavity walls is then collected by the fibers and multiplexed at the proximal end to the sample arm of an optical low coherence reflectometer. The system may also be implemented in a nonmedical inspection device.

  7. High spatial resolution distributed fiber system for multi-parameter sensing based on modulated pulses.

    PubMed

    Zhang, Jingdong; Zhu, Tao; Zhou, Huan; Huang, Shihong; Liu, Min; Huang, Wei

    2016-11-28

    We demonstrate a cost-effective distributed fiber sensing system for the multi-parameter detection of the vibration, the temperature, and the strain by integrating phase-sensitive optical time domain reflectometry (φ-OTDR) and Brillouin optical time domain reflectometry (B-OTDR). Taking advantage of the fast changing property of the vibration and the static properties of the temperature and the strain, both the width and intensity of the laser pulses are modulated and injected into the single-mode sensing fiber proportionally, so that three concerned parameters can be extracted simultaneously by only one photo-detector and one data acquisition channel. A data processing method based on Gaussian window short time Fourier transform (G-STFT) is capable of achieving high spatial resolution in B-OTDR. The experimental results show that up to 4.8kHz vibration sensing with 3m spatial resolution at 10km standard single-mode fiber can be realized, as well as the distributed temperature and stress profiles along the same fiber with 80cm spatial resolution.

  8. Phase-based, high spatial resolution and distributed, static and dynamic strain sensing using Brillouin dynamic gratings in optical fibers.

    PubMed

    Bergman, Arik; Langer, Tomi; Tur, Moshe

    2017-03-06

    A novel technique combining Brillouin phase-shift measurements with Brillouin dynamic gratings (BDGs) reflectometry in polarization-maintaining fibers is presented here for the first time. While a direct measurement of the optical phase in standard BDG setups is impractical due to non-local phase contributions, their detrimental effect is reduced by ~4 orders of magnitude through the coherent addition of Stokes and anti-Stokes reflections from two counter-propagating BDGs in the fiber. The technique advantageously combines the high-spatial-resolution of BDGs reflectometry with the increased tolerance to optical power fluctuations of phasorial measurements, to enhance the performance of fiber-optic strain sensors. We demonstrate a distributed measurement (20cm spatial-resolution) of both static and dynamic (5kHz of vibrations at a sampling rate of 1MHz) strain fields acting on the fiber, in good agreement with theory and (for the static case) with the results of commercial reflectometers.

  9. Millimeter-wave reflectometry for electron density profile and fluctuation measurements on NSTX

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kubota, S.; Nguyen, X. V.; Peebles, W. A.

    2001-01-01

    A millimeter-wave reflectometry system for electron density profile and fluctuation measurements is being developed and installed on the National Spherical Torus Experiment. The initial frequency coverage will be in the bands 12--18, 20--32, and 33--50 GHz, provided by frequency-tunable solid-state sources. These frequencies correspond to O-mode cutoff densities ranging from 1.8x10{sup 12} to 3.1x10{sup 13}cm{sup -3}, which will span both the plasma core ({rho}=r/a<0.8) and edge ({rho}>0.8) regions. Operated as a broadband swept-frequency (frequency-modulated continuous-wave) reflectometer, the diagnostic is expected to provide routine (shot-to-shot) time- ({<=}50 {mu}s) and spatially resolved ({approx}1 cm) density profiles. The previous hardware can be easilymore » reconfigured as a fixed-frequency reflectometer for density fluctuation measurements. The combination of measurements would be valuable for studying phenomena such as possible L- to H-mode transitions and edge-localized modes.« less

  10. Chirped-pulse coherent-OTDR with predistortion

    NASA Astrophysics Data System (ADS)

    Xiong, Ji; Jiang, Jialin; Wu, Yue; Chen, Yongxiang; Xie, Lianlian; Fu, Yun; Wang, Zinan

    2018-03-01

    In this paper, a novel method for generating high-quality chirped pulses with IQ modulator is studied theoretically and experimentally, which is a crucial building block for high-performance coherent optical time-domain reflectometry (COTDR). In order to compensate the nonlinearity of the modulator transfer function, we present a predistortion technique for chirped-pulse coherent optical time-domain reflectometry (CP-COTDR), the arcsin predistortion method and the single sideband with a suppressed carrier analog modulation used to generate the high quality chirped optical pulse. The high order sidebands, due to the large amplitude of the modulation signal and the nonlinear transfer function of the IQ modulator, can be relieved by the predistortion process, which means the power and the quality of the generated chirped pulse has been improved. In the experiment, this method increases the peak power of the chirped pulse by 4.2 dB compared to the case without predistortion process, as for the CP-COTDR system, this method increases the signal-to-noise ratio of the demodulated phase variation by 6.3 dB.

  11. Motofit - integrating neutron reflectometry acquisition, reduction and analysis into one, easy to use, package

    NASA Astrophysics Data System (ADS)

    Nelson, Andrew

    2010-11-01

    The efficient use of complex neutron scattering instruments is often hindered by the complex nature of their operating software. This complexity exists at each experimental step: data acquisition, reduction and analysis, with each step being as important as the previous. For example, whilst command line interfaces are powerful at automated acquisition they often reduce accessibility by novice users and sometimes reduce the efficiency for advanced users. One solution to this is the development of a graphical user interface which allows the user to operate the instrument by a simple and intuitive "push button" approach. This approach was taken by the Motofit software package for analysis of multiple contrast reflectometry data. Here we describe the extension of this package to cover the data acquisition and reduction steps for the Platypus time-of-flight neutron reflectometer. Consequently, the complete operation of an instrument is integrated into a single, easy to use, program, leading to efficient instrument usage.

  12. The Rise of GNSS Reflectometry for Earth Remote Sensing

    NASA Technical Reports Server (NTRS)

    Zuffada, Cinzia; Li, Zhijin; Nghiem, Son V.; Lowe, Steve; Shah, Rashmi; Clarizia, Maria Paola; Cardellach, Estel

    2015-01-01

    The Global Navigation Satellite System (GNSS) reflectometry, i.e. GNSS-R, is a novel remote-sensing technique first published in that uses GNSS signals reflected from the Earth's surface to infer its surface properties such as sea surface height (SSH), ocean winds, sea-ice coverage, vegetation, wetlands and soil moisture, to name a few. This communication discusses the scientific value of GNSS-R to (a) furthering our understanding of ocean mesoscale circulation toward scales finer than those that existing nadir altimeters can resolve, and (b) mapping vegetated wetlands, an emerging application that might open up new avenues to map and monitor the planet's wetlands for methane emission assessments. Such applications are expected to be demonstrated by the availability of data from GEROS-ISS, an ESA experiment currently in phase A, and CyGNSS [3], a NASA mission currently in development. In particular, the paper details the expected error characteristics and the role of filtering played in the assimilation of these data to reduce the altimetric error (when averaging many measurements).

  13. Wetland monitoring with Global Navigation Satellite System reflectometry

    PubMed Central

    Zuffada, Cinzia; Shah, Rashmi; Chew, Clara; Lowe, Stephen T.; Mannucci, Anthony J.; Cardellach, Estel; Brakenridge, G. Robert; Geller, Gary; Rosenqvist, Ake

    2017-01-01

    Abstract Information about wetland dynamics remains a major missing gap in characterizing, understanding, and projecting changes in atmospheric methane and terrestrial water storage. A review of current satellite methods to delineate and monitor wetland change shows some recent advances, but much improved sensing technologies are still needed for wetland mapping, not only to provide more accurate global inventories but also to examine changes spanning multiple decades. Global Navigation Satellite Systems Reflectometry (GNSS‐R) signatures from aircraft over the Ebro River Delta in Spain and satellite measurements over the Mississippi River and adjacent watersheds demonstrate that inundated wetlands can be identified under different vegetation conditions including a dense rice canopy and a thick forest with tall trees, where optical sensors and monostatic radars provide limited capabilities. Advantages as well as constraints of GNSS‐R are presented, and the synergy with various satellite observations are considered to achieve a breakthrough capability for multidecadal wetland dynamics monitoring with frequent global coverage at multiple spatial and temporal scales. PMID:28331894

  14. Enhancement of accuracy in shape sensing of surgical needles using optical frequency domain reflectometry in optical fibers.

    PubMed

    Parent, Francois; Loranger, Sebastien; Mandal, Koushik Kanti; Iezzi, Victor Lambin; Lapointe, Jerome; Boisvert, Jean-Sébastien; Baiad, Mohamed Diaa; Kadoury, Samuel; Kashyap, Raman

    2017-04-01

    We demonstrate a novel approach to enhance the precision of surgical needle shape tracking based on distributed strain sensing using optical frequency domain reflectometry (OFDR). The precision enhancement is provided by using optical fibers with high scattering properties. Shape tracking of surgical tools using strain sensing properties of optical fibers has seen increased attention in recent years. Most of the investigations made in this field use fiber Bragg gratings (FBG), which can be used as discrete or quasi-distributed strain sensors. By using a truly distributed sensing approach (OFDR), preliminary results show that the attainable accuracy is comparable to accuracies reported in the literature using FBG sensors for tracking applications (~1mm). We propose a technique that enhanced our accuracy by 47% using UV exposed fibers, which have higher light scattering compared to un-exposed standard single mode fibers. Improving the experimental setup will enhance the accuracy provided by shape tracking using OFDR and will contribute significantly to clinical applications.

  15. Simultaneous polarized neutron reflectometry and anisotropic magnetoresistance measurements.

    PubMed

    Demeter, J; Teichert, A; Kiefer, K; Wallacher, D; Ryll, H; Menéndez, E; Paramanik, D; Steitz, R; Van Haesendonck, C; Vantomme, A; Temst, K

    2011-03-01

    A novel experimental facility to carry out simultaneous polarized neutron reflectometry (PNR) and anisotropic magnetoresistance (AMR) measurements is presented. Performing both techniques at the same time increases their strength considerably. The proof of concept of this method is demonstrated on a CoO/Co bilayer exchange bias system. Although information on the same phenomena, such as the coercivity or the reversal mechanism, can be separately obtained from either of these techniques, the simultaneous application optimizes the consistency between both. In this way, possible differences in experimental conditions, such as applied magnetic field amplitude and orientation, sample temperature, magnetic history, etc., can be ruled out. Consequently, only differences in the fundamental sensitivities of the techniques can cause discrepancies in the interpretation between the two. The almost instantaneous information obtained from AMR can be used to reveal time-dependent effects during the PNR acquisition. Moreover, the information inferred from the AMR measurements can be used for optimizing the experimental conditions for the PNR measurements in a more efficient way than with the PNR measurements alone.

  16. Isotope effect in heavy/light water suspensions of optically active gold nanoparticles

    NASA Astrophysics Data System (ADS)

    Kutsenko, V. Y.; Artykulnyi, O. P.; Petrenko, V. I.; Avdeev, M. V.; Marchenko, O. A.; Bulavin, L. A.; Snegir, S. V.

    2018-04-01

    Aqueous suspensions of optically active gold nanoparticles coated with trisodium citrate were synthesized in light (H2O) water and mixture of light and heavy (H2O/D2O) water using the modified Turkevich protocol. The objective of the paper was to verify sensitivity of neutron scattering methods (in particular, neutron reflectometry) to the potential isotope H/D substitution in the stabilizing organic shell around particles in colloidal solutions. First, the isotope effect was studied with respect to the changes in the structural properties of metal particles (size, shape, crystalline morphology) in solutions by electron microscopy including high-resolution transmission electron microscopy from dried systems. The structural factors determining the variation in the adsorption spectra in addition to the change in the optical properties of surrounding medium were discussed. Then, neutron reflectometry was applied to the layered nanoparticles anchored on a silicon wafer via 3-aminopropyltriethoxysilane molecules to reveal the presence of deuterated water molecules in the shell presumably formed by citrate molecules around the metallic core.

  17. Long-term changes in body weight are associated with changes in blood pressure levels.

    PubMed

    Markus, M R P; Ittermann, T; Baumeister, S E; Troitzsch, P; Schipf, S; Lorbeer, R; Aumannn, N; Wallaschofski, H; Dörr, M; Rettig, R; Völzke, H

    2015-03-01

    Hypertension and obesity are highly prevalent in Western societies. We investigated the associations of changes in body weight with changes in blood pressure and with incident hypertension, incident cardiovascular events, or incident normalization of blood pressure in patients who were hypertensive at baseline, over a 5-year period. Data of men and women aged 20-81 years of the Study of Health in Pomerania were used. Changes in body weight were related to changes in blood pressure by linear regression (n = 1875) adjusted for cofounders. Incident hypertension, incident cardiovascular events, or incident blood pressure normalization in patients who were hypertensive at baseline were investigated using Poisson regression (n = 3280) models. A change of 1 kg in body weight was positively associated with a change of 0.45 mm Hg (95% confidence interval (CI): 0.34-0.55 mm Hg) in systolic blood pressure, 0.32 mm Hg (95% CI: 0.25-0.38 mm Hg) in diastolic blood pressure, and 0.36 mm Hg (95% CI: 0.29-0.43 mm Hg) in mean arterial pressure (all p-values <0.001). A 5% weight loss reduced the relative risk (RR) of incident hypertension (RRs 0.84 (95% CI: 0.79-0.89)) and incident cardiovascular events (RRs 0.81 (95% CI: 0.68-0.98)) and increased the chance of incident blood pressure normalization in patients who were hypertensive at baseline by 15% (95% CI: 7-23%). Absolute and relative changes in body weight are positively associated with changes in blood pressure levels and also affect the risk of cardiovascular events. Copyright © 2014 Elsevier B.V. All rights reserved.

  18. Memory Binding Test Predicts Incident Amnestic Mild Cognitive Impairment.

    PubMed

    Mowrey, Wenzhu B; Lipton, Richard B; Katz, Mindy J; Ramratan, Wendy S; Loewenstein, David A; Zimmerman, Molly E; Buschke, Herman

    2016-07-14

    The Memory Binding Test (MBT), previously known as Memory Capacity Test, has demonstrated discriminative validity for distinguishing persons with amnestic mild cognitive impairment (aMCI) and dementia from cognitively normal elderly. We aimed to assess the predictive validity of the MBT for incident aMCI. In a longitudinal, community-based study of adults aged 70+, we administered the MBT to 246 cognitively normal elderly adults at baseline and followed them annually. Based on previous work, a subtle reduction in memory binding at baseline was defined by a Total Items in the Paired (TIP) condition score of ≤22 on the MBT. Cox proportional hazards models were used to assess the predictive validity of the MBT for incident aMCI accounting for the effects of covariates. The hazard ratio of incident aMCI was also assessed for different prediction time windows ranging from 4 to 7 years of follow-up, separately. Among 246 controls who were cognitively normal at baseline, 48 developed incident aMCI during follow-up. A baseline MBT reduction was associated with an increased risk for developing incident aMCI (hazard ratio (HR) = 2.44, 95% confidence interval: 1.30-4.56, p = 0.005). When varying the prediction window from 4-7 years, the MBT reduction remained significant for predicting incident aMCI (HR range: 2.33-3.12, p: 0.0007-0.04). Persons with poor performance on the MBT are at significantly greater risk for developing incident aMCI. High hazard ratios up to seven years of follow-up suggest that the MBT is sensitive to early disease.

  19. The use of recycled concrete aggregate in a dense graded aggregate base course.

    DOT National Transportation Integrated Search

    2008-03-01

    The research project was broken up into 2 different parts. The first part involved evaluating the potential use of the Time : Domain Reflectometry, TDR (ASTM D6780), as a non-nuclear means for determining the dry density and moisture content of : gra...

  20. Combining Cubic Spline Interpolation and Fast Fourier Transform to Extend Measuring Range of Reflectometry

    NASA Astrophysics Data System (ADS)

    Cheng, Ju; Lu, Jian; Zhang, Hong-Chao; Lei, Feng; Sardar, Maryam; Bian, Xin-Tian; Zuo, Fen; Shen, Zhong-Hua; Ni, Xiao-Wu; Shi, Jin

    2018-05-01

    Not Available Supported by the National Natural Science Foundation of China under Grant No 11604115, the Educational Commissionof Jiangsu Province of China under Grant No 17KJA460004, and the Huaian Science and Technology Funds under Grant NoHAC201701.

  1. Effects of Multiple Crimps and Cable Length on Reflection Signatures from Long Cables

    DOT National Transportation Integrated Search

    2002-03-19

    The accuracy of time domain reflectometry (TDR) measurements of rock shearing with cable lengths greater than 60 m has not been adequately documented. This paper presents the results of controlled crimping and shearing of a 530 m long, 22.2mm diamete...

  2. Neonatal screening for glucose-6-phosphate dehydrogenase deficiency.

    PubMed

    Pao, Mritunjay; Kulkarni, Anjali; Gupta, Vidya; Kaul, Sushma; Balan, Saroja

    2005-10-01

    This study was carried out to detect the incidence of erythrocytic Glucose-6 -Phosphate dehydrogenase (G-6-PD) deficiency, to compare the incidence of hyperbilirubinemia in G-6-PD deficient neonates as compared to G-6-PD normal neonates and to asses the usefulness of neonatal screening for G-6-PD deficiency. In a retrospective hospital based study 2,479 male and female neonates consecutively born at Indraprastha Apollo hospital between July 1998 to June 2003 who were screened for G-6-PD levels were evaluated for the incidence of G-6-PD deficiency. Incidence of G-6-PD deficiency was found to be 2.0%. Incidence in males was 283% and female was 1.05%. The incidence of hyperbilirubinemia was found to be 32% in G-6-PD deficient neonates which was significantly higher than the incidence of hyperbilirubinemia in neonates with normal G-6-PD, which was 12.3% (P< 0.001). Our data suggests that neonatal screening for G-6-PD deficiency is a useful test for preventing and early treatment of complications associated with it.

  3. Initial transport validation studies using NSTX-U L-mode plasmas

    NASA Astrophysics Data System (ADS)

    Guttenfelder, Walter; Battaglia, D.; Bell, R. E.; Boyer, M. D.; Crocker, N.; Diallo, A.; Ferraro, N.; Gerhardt, S. P.; Kaye, S. M.; Leblanc, B. P.; Liu, D.; Menard, J. E.; Mueller, D.; Myer, C.; Podesta, M.; Raman, R.; Ren, Y.; Sabbagh, S.; Smith, D.

    2016-10-01

    A variety of stationary L-mode plasmas have been successfully developed in NSTX-U for physics validation studies. The plasmas span a range of density (1-4 ×1019 m-3) , plasma current (0.65-1.0 MA), and neutral beam heating power (<=4 MW), taking advantage of new, more tangential neutral beam sources to vary rotation profiles. Transport analysis (TRANSP) and turbulence measurements (BES, reflectometry) of these plasmas will be illustrated and compared with initial microstability and transport predictions. In particular, the normalized beta of these L-modes range between βN = 1-2, providing a valuable bridge in parameter space between (i) H-modes at comparable beta in conventional tokamaks (R/a 3, βN 2), where transport models have been largely developed and tested, and (ii) low-aspect-ratio H-modes at higher beta (R/a 1.5-1.7, βN 5), where transport models are less tested and challenged by stronger electromagnetic and equilibrium effects. This work is supported by US DOE contract DE-AC02-09CH11466.

  4. Design of a normal incidence multilayer imaging x-ray microscope.

    PubMed

    Shealy, D L; Gabardi, D R; Hoover, R B; Walker, A B; Lindblom, J F; Barbee, T W

    1989-01-01

    Normal incidence multilayer Cassegrain x-ray telescopes were flown on the Stanford/MSFC Rocket X-Ray Spectroheliograph. These instruments produced high spatial resolution images of the Sun and conclusively demonstrated that doubly reflecting multilayer x-ray optical systems are feasible. The images indicated that aplanatic imaging soft x-ray /EUV microscopes should be achievable using multilayer optics technology. We have designed a doubly reflecting normal incidence multilayer imaging x-ray microscope based on the Schwarzschild configuration. The Schwarzschild microscope utilizes two spherical mirrors with concentric radii of curvature which are chosen such that the third-order spherical aberration and coma are minimized. We discuss the design of the microscope and the results of the optical system ray trace analysis which indicates that diffraction-limited performance with 600 Å spatial resolution should be obtainable over a 1 mm field of view at a wavelength of 100 Å. Fabrication of several imaging soft x-ray microscopes based upon these designs, for use in conjunction with x-ray telescopes and laser fusion research, is now in progress. High resolution aplanatic imaging x-ray microscopes using normal incidence multilayer x-ray mirrors should have many important applications in advanced x-ray astronomical instrumentation, x-ray lithography, biological, biomedical, metallurgical, and laser fusion research.

  5. Characterization of Delaminations and Transverse Matrix Cracks in Composite Laminates Using Multiple-Angle Ultrasonic Inspection

    NASA Technical Reports Server (NTRS)

    Johnston, Patrick H.; Appleget, Chelsea D.; Odarczenko, Michael T.

    2012-01-01

    Delaminations and transverse matrix cracks often appear concurrently in composite laminates. Normal-incidence ultrasound is excellent at detecting delaminations, but is not optimum for matrix cracks. Non-normal incidence, or polar backscattering, has been shown to optimally detect matrix cracks oriented perpendicular to the ultrasonic plane of incidence. In this work, a series of six composite laminates containing slots were loaded in tension to achieve various levels of delamination and ply cracking. Ultrasonic backscattering was measured over a range of incident polar and azimuthal angles, in order to characterize the relative degree of damage of the two types. Sweptpolar- angle measurements were taken with a curved phased array, as a step toward an array-based approach to simultaneous measurement of combined flaws.

  6. Calibration and Use of B Dot Probes for Electromagnetic Measuring

    DTIC Science & Technology

    1977-08-09

    response. E. Time Domain Reflectometry Measurements Pulse impedance measurements for the 1.75-in. diameter double-gap probe design were first performed...Far Field (Radiation) Patterns of a B Dot Probe 1. Anechoic Chamber The facility utilized for the probe patterns was the NASA 120-ft chamber at

  7. Rome Air Development Center Air Force Technical Objective Document FY88

    DTIC Science & Technology

    1986-12-01

    resistant fiber ontic links. flotical time domain reflectometry , refractive index nrofiling, exhaustive measurements and analysis, and optical fi her cable...application. This technology ma/ be directly applied to other mission applications as has been shown by both NASA and the US Navy. A major thrust of the Al

  8. Spatial Distribution of Surface Soil Moisture in a Small Forested Catchment

    EPA Science Inventory

    Predicting the spatial distribution of soil moisture is an important hydrological question. We measured the spatial distribution of surface soil moisture (upper 6 cm) using an Amplitude Domain Reflectometry sensor at the plot scale (2 × 2 m) and small catchment scale (0.84 ha) in...

  9. Profiling soil water content sensor

    USDA-ARS?s Scientific Manuscript database

    A waveguide-on-access-tube (WOAT) sensor system based on time domain reflectometry (TDR) principles was developed to sense soil water content and bulk electrical conductivity in 20-cm (8 inch) deep layers from the soil surface to depths of 3 m (10 ft) (patent No. 13/404,491 pending). A Cooperative R...

  10. Design of access-tube TDR sensor for soil water content: Theory

    USDA-ARS?s Scientific Manuscript database

    The design of a cylindrical access-tube mounted waveguide was developed for in-situ soil water content sensing using time-domain reflectometry (TDR). To optimize the design with respect to sampling volume and losses, we derived the electromagnetic fields produced by a TDR sensor with cylindrical geo...

  11. Short, multi-needle FDR sensor suitable for measuring soil water content

    USDA-ARS?s Scientific Manuscript database

    Time domain reflectometry (TDR) is a well-established electromagnetic technique used to measure soil water content. TDR sensors have been combined with heat pulse sensors to produce thermo-TDR sensors. Thermo-TDR sensors are restricted to having relatively short needles in order to accurately measur...

  12. A complex permittivity model for field estimation of soil water contents using time domain reflectometry

    USDA-ARS?s Scientific Manuscript database

    Accurate electromagnetic sensing of soil water contents (') under field conditions is complicated by the dependence of permittivity on specific surface area, temperature, and apparent electrical conductivity, all which may vary across space or time. We present a physically-based mixing model to pred...

  13. Diffuse X-ray scattering near a two-dimensional solid–liquid phase transition at the n-hexane–water interface

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tikhonov, A. M.

    According to experimental data on X-ray scattering and reflectometry with synchrotron radiation, a twodimensional crystallization phase transition in a monolayer of melissic acid at the n-hexane–water interface with a decrease in the temperature occurs after a wetting transition.

  14. Selected nursery projects at the Missoula Technology and Development Center

    Treesearch

    Brian Vachowski

    2007-01-01

    The USDA Forest Service Missoula Technology and Development Center (MTDC) offers technical expertise, technology transfer, and new equipment development to federal, state, and private forest nurseries. Current and recently completed projects at MTDC include a container block steam sterilizer, shielded herbicide sprayer, time-domain reflectometry (TDR) nursery soil...

  15. The Skinny on Sexual Risk: The Effects of BMI on STI Incidence and Risk

    PubMed Central

    Arnold, Anna; Lewis, Jessica B.; Magriples, Urania; Ickovics, Jeannette R.

    2011-01-01

    Few studies examine the influence of body mass index (BMI) on sexual risk. The purpose of this study was to determine whether BMI among 704 young mothers (ages 14–25) related to STI incidence and sexual risk. We examined the effect of BMI groups (normal weight, overweight, and obese) at 6 months postpartum on STI incidence and risky sex (e.g., unprotected sex, multiple partners, risky and casual partner) at 12 months post-partum. At 6 months postpartum, 31% of participants were overweight and 40% were obese. Overweight women were more likely to have an STI (OR = 1.79, 95% CI = 1.11–2.89, P < .05) and a risky partner (OR = 1.64, 95% CI = 1.01–2.08, P < .05) at 12 months postpartum compared to normal weight women. However, obese women were less likely to have an STI than normal weight women (OR = .57, 95% CI = .34–.96, P < .01). BMI related to STI incidence and sexual risk behavior. Integrated approaches to weight loss and sexual risk prevention should be explored. PMID:20976536

  16. EUV near normal incidence collector development at SAGEM

    NASA Astrophysics Data System (ADS)

    Mercier Ythier, R.; Bozec, X.; Geyl, R.; Rinchet, A.; Hecquet, Christophe; Ravet-Krill, Marie-Françoise; Delmotte, Franck; Sassolas, Benoît; Flaminio, Raffaele; Mackowski, Jean-Marie; Michel, Christophe; Montorio, Jean-Luc; Morgado, Nazario; Pinard, Laurent; Roméo, Elodie

    2008-03-01

    Through its participation to European programs, SAGEM has worked on the design and manufacturing of normal incidence collectors for EUV sources. By opposition to grazing incidence, normal incidence collectors are expected to collect more light with a simpler and cheaper design. Designs are presented for the two current types of existing sources: Discharge Produced Plasma (DPP) and Laser Produced Plasma (LPP). Collection efficiency is calculated in both cases. It is shown that these collectors can achieve about 10 % efficiency for DPP sources and 40 % for LPP sources. SAGEM works on the collectors manufacturability are also presented, including polishing, coating and cooling. The feasibility of polishing has been demonstrated with a roughness better than 2 angstroms obtained on several materials (glass, silicon, Silicon Carbide, metals...). SAGEM is currently working with the Institut d'Optique and the Laboratoire des Materiaux Avancés on the design and the process of EUV coatings for large mirrors. Lastly, SAGEM has studied the design and feasibility of an efficient thermal control, based on a liquid cooling through slim channels machined close to the optical surface.

  17. [The relationship of ECG and pregnancy outcome of older pregnant woman in late pregnancy].

    PubMed

    Zhao, Xiao-Qin; Wang, Chun-Guang; Song, Yu-Xia; Jiao, Hong

    2014-01-01

    To observe the changes of electrocardiogram (ECG) and pregnancy outcome of the late pregnancy women. Late pregnancy women were divided into two groups by age: over 35 group and under 35 group. The incidence of abnormal electrocardiogram was recorded when the patients were subjected to routine ECG examination. Then the pregnancy, delivery outcome and if there's low birth weight newborn were recorded later. The incidence of abnormal ECG in over 35 group was significantly higher than that in under 35 group (P < 0.05). And the incidence of ST segment changes, arrhythmia in the group of former was higher than that in the group of latter (P < 0.05). Among the different type of arrhythmia, the incidence of sinus bradycardia and ventricular premature beat in the group of former were higher than those in the group of latter (P < 0.05). But the incidence of sinus tachycardia in the former group was obviously lower than that in the latter group (P < 0.05). The incidence of pregnancy loss in over 35 with abnormal ECG group was significantly higher than that in under 35 with normal or abnormal ECG groups (P < 0.05). The incidence of premature birth in over 35 with abnormal ECG group was significantly higher than that in over 35 with normal ECG group (P < 0.05). The incidence of low body weight in over 35 with abnormal ECG group was significantly higher than that in under 35 with normal ECG group (P < 0.05). The late pregnancy women with the age of over 35 are more likely to have ECG abnormalities, such as arrhythmia, myocardial ischemia and so on. The older pregnant women with abnormal ECG easily suffer from pregnancy losing, premature birth and having a low birth weight baby.

  18. Comparison of Atomic Oxygen Erosion Yields of Materials at Various Energy and Impact Angles

    NASA Technical Reports Server (NTRS)

    Banks, Bruce A.; Waters, Deborah L.; Thorson, Stephen D.; deGroh, Kim, K.; Snyder, Aaron; Miller, Sharon

    2006-01-01

    The atomic oxygen erosion yields of various materials, measured in volume of material oxidized per incident atomic oxygen atom, are compared to the commonly accepted standard of Kapton H (DuPont) polyimide. The ratios of the erosion yield of Kapton H to the erosion yield of various materials are not consistent at different atomic oxygen energies. Although it is most convenient to use isotropic thermal energy RF plasma ashers to assess atomic oxygen durability, the results can be misleading because the relative erosion rates at thermal energies are not necessarily the same as low Earth orbital (LEO) energies of approx.4.5 eV. An experimental investigation of the relative atomic oxygen erosion yields of a wide variety of polymers and carbon was conducted using isotropic thermal energy (approx.0.1 eV) and hyperthermal energy (approx.70 eV) atomic oxygen using an RF plasma asher and an end Hall ion source. For hyperthermal energies, the atomic oxygen erosion yields relative to normal incident Kapton H were compared for sweeping atomic oxygen arrival with that of normal incidence arrival. The results of isotropic thermal energy, normal incident, and sweeping incident atomic oxygen are also compared with measured or projected LEO values.

  19. Design of a Monocular Multi-Spectral Skin Detection, Melanin Estimation, and False-Alarm Suppression System

    DTIC Science & Technology

    2010-03-01

    3-21 3.22. Measured transmission of the Semrock FF01-1060/13-25 NIR bandpass filter at normal incidence. . . . . . . . . . . . . . . . 3-22...3.23. Measured transmission of the Semrock NIR01-1570/3-25 NIR bandpass filter at normal incidence. . . . . . . . . . . . . . . . 3-23 3.24. Measured...shows the configuration without additional filtering while the blue adds the Semrock bandpass filter. . . . 3-30 3.34. (Left) Spectral transmittance

  20. Quantum Well Intrasubband Photodetector for Far Infared and Terahertz Radiation Detection

    NASA Technical Reports Server (NTRS)

    Ting, David Z. -Y.; Chang, Yia-Chung; Bandara, Sumith V.; Gunapala, Sarath D.

    2007-01-01

    The authors present a theoretical analysis on the possibility of using the dopant-assisted intrasubband absorption mechanism in quantum wells for normal-incidence far infrared/terahertz radiation detection. The authors describe the proposed concept of the quantum well intrasubband photodetector (QWISP), which is a compact semiconductor heterostructure device compatible with existing GaAs focal-plane array technology, and present theoretical results demonstrating strong normal-incidence absorption and responsivity in the QWISP.

  1. Interference effects on guided Cherenkov emission in silicon from perpendicular, oblique, and parallel boundaries

    NASA Astrophysics Data System (ADS)

    Couillard, M.; Yurtsever, A.; Muller, D. A.

    2010-05-01

    Waveguide electromagnetic modes excited by swift electrons traversing Si slabs at normal and oblique incidence are analyzed using monochromated electron energy-loss spectroscopy and interpreted using a local dielectric theory that includes relativistic effects. At normal incidence, sharp spectral features in the visible/near-infrared optical domain are directly assigned to p -polarized modes. When the specimen is tilted, s -polarized modes, which are completely absent at normal incidence, become visible in the loss spectra. In the tilted configuration, the dispersion of p -polarized modes is also modified. For tilt angles higher than ˜50° , Cherenkov radiation, the phenomenon responsible for the excitation of waveguide modes, is expected to partially escape the silicon slab and the influence of this effect on experimental measurements is discussed. Finally, we find evidence for an interference effect at parallel Si/SiO2 interfaces, as well as a delocalized excitation of guided Cherenkov modes.

  2. Risk of Progression to Hypertension in a Low-Income Mexican Population with Pre-hypertension and Normal Blood Pressure

    PubMed Central

    Jimenez-Corona, Aida; Lopez-Ridaura, Ruy; Stern, Michael P; Gonzalez-Villalpando, Clicerio

    2007-01-01

    BACKGROUND Blood pressure (BP) levels below the pre-hypertension category may be associated with the risk of developing hypertension. We estimated the incidence rates of hypertension in low-income Mexican population according to several subcategories of baseline BP within normal and pre-hypertension categories. METHODS A total of 1572 nonhypertensive men (n=632) and non-pregnant women (n=940), aged 35 to 64 years at baseline, were followed for a median of 5.8 years. Hypertension was defined as systolic blood pressure (SBP) ≥140 mm Hg, diastolic blood pressure (DBP) ≥90 mm Hg, or self-reported physician diagnosis with anti-hypertensive medications. RESULTS During follow-up, 267 subjects developed hypertension, of whom 83 were men and 184 were women. Age-adjusted incidence rate was higher in women (37.1 per 1000 person-years) than in men (23.7 per 1000 person-years). There was a significant association between BP levels at baseline and hypertension incidence even within the normal category. For the upper levels of normal SBP (110-119 mm Hg), the HR (95%CI) was 2.43 (1.50-3.93) in women and 2.44 (1.05-5.69) in men, compared with SBP <110 mm Hg. For the upper levels of normal DBP (70-79 mm Hg), the HR (95%CI) was 2.33 (1.65-3.31) in women and 1.80 (0.92-3.52) in men, compared with DBP <70 mm Hg, after adjustment for recognized predictors. CONCLUSIONS High risk of hypertension incidence was associated with levels of BP even within the normal category. This information could help define a population at high risk of progression to hypertension, in order to establish preventive measures. PMID:17765131

  3. The Association between Persistent Hypertriglyceridemia and the Risk of Diabetes Development: The Kangbuk Samsung Health Study.

    PubMed

    Kwon, Yu Hyun; Kim, Seul Ki; Cho, Jung Hwan; Kwon, Hyemi; Park, Se Eun; Oh, Hyung Geun; Park, Cheol Young; Lee, Won Young; Oh, Ki Won; Park, Sung Woo; Rhee, Eun Jung

    2018-03-01

    Hypertriglyceridemia is known to have an association with increased risks of insulin resistance and diabetes. The aim of this study was to investigate the risk of diabetes mellitus, according to changes in the concentrations of triglycerides, over time. A total of 15,932 non-diabetic participants (mean age 43.2 years, 68% men) who attended five consecutive annual health check-ups at Kangbuk Samsung Hospital, between January 2010 and December 2014, were recruited. Participants were classified according to their triglyceride concentrations; normal (<150 mg/dL) and abnormal (≥150 mg/dL). According to the triglyceride levels in 2010 and 2012, subjects were divided into four groups: normal-normal, normal-abnormal, abnormal-normal, and abnormal-abnormal. The risk for incident diabetes was assessed in 2014. Among the total subjects, 67.5% belonged to the normal-normal group, 8.6% to the normal-abnormal group, 9.4% to the abnormal-normal group, and 14.5% to the abnormal-abnormal group. A total of 234 subjects (1.5%) were newly diagnosed with diabetes, between 2010 and 2014. Over 4 years, 1%, 1.5%, 2.1%, and 3.0% of the subjects developed diabetes in the normal-normal, normal-abnormal, abnormal-normal, and abnormal-abnormal groups, respectively. When the risk for incident diabetes was analyzed in the groups, after adjusting the confounding variables, a 1.58-fold increase in the risk of diabetes (95% confidence interval [CI], 1.10 to 2.26) was observed in the participants with persistent hypertriglyceridemia (abnormal-abnormal group). This was attenuated by further adjustments for body mass index (BMI) (hazard ratio, 1.25; 95% CI, 0.86 to 1.80). In this large study population, persistent hypertriglyceridemia, over a period of 2 years, was significantly associated with the risk of incident diabetes, which was attenuated after adjustment for BMI. Copyright © 2018 Korean Endocrine Society.

  4. The Association between Persistent Hypertriglyceridemia and the Risk of Diabetes Development: The Kangbuk Samsung Health Study

    PubMed Central

    Kwon, Yu Hyun; Kim, Seul-Ki; Cho, Jung Hwan; Kwon, Hyemi; Park, Se Eun; Oh, Hyung-Geun; Park, Cheol-Young; Lee, Won-Young; Oh, Ki-Won; Park, Sung-Woo

    2018-01-01

    Background Hypertriglyceridemia is known to have an association with increased risks of insulin resistance and diabetes. The aim of this study was to investigate the risk of diabetes mellitus, according to changes in the concentrations of triglycerides, over time. Methods A total of 15,932 non-diabetic participants (mean age 43.2 years, 68% men) who attended five consecutive annual health check-ups at Kangbuk Samsung Hospital, between January 2010 and December 2014, were recruited. Participants were classified according to their triglyceride concentrations; normal (<150 mg/dL) and abnormal (≥150 mg/dL). According to the triglyceride levels in 2010 and 2012, subjects were divided into four groups: normal-normal, normal-abnormal, abnormal-normal, and abnormal-abnormal. The risk for incident diabetes was assessed in 2014. Results Among the total subjects, 67.5% belonged to the normal-normal group, 8.6% to the normal-abnormal group, 9.4% to the abnormal-normal group, and 14.5% to the abnormal-abnormal group. A total of 234 subjects (1.5%) were newly diagnosed with diabetes, between 2010 and 2014. Over 4 years, 1%, 1.5%, 2.1%, and 3.0% of the subjects developed diabetes in the normal-normal, normal-abnormal, abnormal-normal, and abnormal-abnormal groups, respectively. When the risk for incident diabetes was analyzed in the groups, after adjusting the confounding variables, a 1.58-fold increase in the risk of diabetes (95% confidence interval [CI], 1.10 to 2.26) was observed in the participants with persistent hypertriglyceridemia (abnormal-abnormal group). This was attenuated by further adjustments for body mass index (BMI) (hazard ratio, 1.25; 95% CI, 0.86 to 1.80). Conclusion In this large study population, persistent hypertriglyceridemia, over a period of 2 years, was significantly associated with the risk of incident diabetes, which was attenuated after adjustment for BMI. PMID:29388400

  5. [Application of the life table method to the estimation of late complications of normal tissues after radiotherapy].

    PubMed

    Morita, K; Uchiyama, Y; Tominaga, S

    1987-06-01

    In order to evaluate the treatment results of radiotherapy it is important to estimate the degree of complications of the surrounding normal tissues as well as the frequency of tumor control. In this report, the cumulative incidence rate of the late radiation injuries of the normal tissues was calculated using the modified actuarial method (Cutler-Ederer's method) or Kaplan-Meier's method, which is usually applied to the calculation of the survival rate. By the use of this method of calculation, an accurate cumulative incidence rate over time can be easily obtained and applied to the statistical evaluation of the late radiation injuries.

  6. Incidence and Determinants of Port Occlusions in Cancer Outpatients: A Prospective Cohort Study.

    PubMed

    Milani, Alessandra; Mazzocco, Ketti; Gandini, Sara; Pravettoni, Gabriella; Libutti, Livio; Zencovich, Claudia; Sbriglia, Ada; Pari, Chiara; Magon, Giorgio; Saiani, Luisa

    Normal saline is considered a safe alternative for heparin as a locking solution in totally implantable venous access devices. The incidence rate of partial occlusion with the use of normal saline (easy injection, impossible aspiration) is estimated at 4%. The aim of this study was to investigate determinants of partial occlusions with the use of normal saline solution and the maintenance of positive pressure in the catheter. We enrolled 218 patients with different solid tumors who underwent pharmacologic treatment through the port with different frequencies: from once every week to at least once every month. The port was flushed with normal saline solution keeping a positive pressure in the catheter. We performed 4111 observations and documented normal port functioning in 99% of observations (n = 4057) and partial occlusions in 1% of observations (n = 54). Partial occlusions were significantly associated with frequency of port flushing (P < .05), chemotherapy (P < .001), and blood sample collection (P < .001). The use of positive pressure in addition to normal saline reduces the incidence rate of partial occlusions. The type of treatment, blood sample collection, and treatment schedule are important determinants of partial occlusions. Nurses play a key role in maintaining a functioning port using positive pressure during the flushing techniques. Certain risk factors must be monitored to prevent partial occlusions, and certain patients are more likely to present with port-related problems.

  7. Cumulative increased risk of incident type 2 diabetes mellitus with increasing triglyceride glucose index in normal-weight people: The Rural Chinese Cohort Study.

    PubMed

    Zhang, Ming; Wang, Bingyuan; Liu, Yu; Sun, Xizhuo; Luo, Xinping; Wang, Chongjian; Li, Linlin; Zhang, Lu; Ren, Yongcheng; Zhao, Yang; Zhou, Junmei; Han, Chengyi; Zhao, Jingzhi; Hu, Dongsheng

    2017-03-01

    Risk of type 2 diabetes mellitus (T2DM) is increased in metabolically obese but normal-weight people. However, we have limited knowledge of how to prevent T2DM in normal-weight people. We aimed to evaluate the association between triglyceride glucose (TyG) index and incident T2DM among normal-weight people in rural China. We included data from 5706 people with normal body mass index (BMI) (18.5-23.9 kg/m 2 ) without baseline T2DM in a rural Chinese cohort followed for a median of 6.0 years. A Cox proportional-hazard model was used to assess the risk of incident T2DM by quartiles of TyG index and difference in TyG index between follow-up and baseline (TyG-D), estimating hazard ratios (HRs) and 95% confidence intervals (CIs). A generalized additive plot was used to show the nonparametric smoothed exposure-response association between risk of T2DM and TyG index as a continuous variable. TyG was calculated as ln [fasting triglyceride level (mg/dl) × fasting plasma glucose level (mg/dl)/2]. Risk of incident T2DM was increased with quartiles 2, 3 and 4 versus quartile 1 of TyG index (adjusted HR [aHR] 2.48 [95% CI 1.20-5.11], 3.77 [1.83-7.79], and 5.30 [2.21-12.71], P trend  < 0.001 across quartiles of TyG index). Risk of incident T2DM was increased with quartile 4 versus quartile 1 of TyG-D (aHR 3.91 [2.22-6.87]). The results were consistent when analyses were restricted to participants without baseline metabolic syndrome and impaired fasting glucose level. The generalized additive plot showed cumulative increased risk of T2DM with increasing TyG index. Risk of incident T2DM is increased with increasing TyG index among rural Chinese people, so the index might be an important indicator for identifying people at high risk of T2DM.

  8. INNOVATIVE CONCEPTS FOR DETECTING AND LOCATING LEAKS IN WASTE IMPOUNDMENT LINER SYSTEMS: ACOUSTIC EMISSION MONITORING AND TIME DOMAIN REFLECTOMETRY

    EPA Science Inventory

    This project is part of a program to investigate the use of innovative techniques for detecting and locating leaks in waste impoundment liners. Laboratory and small scale field studies were undertaken to evaluate the potential of Acoustic Emission Monitoring (AEM) and Time Domain...

  9. Flight Test Experiments Foreseen for USV

    DTIC Science & Technology

    2005-10-01

    USA W.T. - Japan W .T. - Australia: ANU ( National University) W .T. - USA: NASA , AEDC, CALTEC, CUBRC W .T. - Japan: NAL 1.0E-05 1.0E-04... reflectometry ”. • Active (TX / RX) / passive (RX only) mode experiments • Main on-board elements: • RX • TX (possibly shared with system TX) • antennas

  10. Design and field tests of a directly coupled waveguide-on-access-tube soil water sensor

    USDA-ARS?s Scientific Manuscript database

    Sensor systems capable of monitoring soil water content can provide a useful tool for irrigation control. Current systems are limited by installation depth, labor, accuracy, and cost. Time domain reflectometry (TDR) is an approach for monitoring soil water content that relates the travel time of an ...

  11. Design and testing of access-tube TDR soil water sensor

    USDA-ARS?s Scientific Manuscript database

    We developed the design of a waveguide on the exterior of an access tube for use in time-domain reflectometry (TDR) for in-situ soil water content sensing. In order to optimize the design with respect to sampling volume and losses, we derived the electromagnetic (EM) fields produced by a TDR sensor...

  12. Field performance of three real-time moisture sensors in sandy loam and clay loam soils

    USDA-ARS?s Scientific Manuscript database

    The study was conducted to evaluate HydraProbe (HyP), Campbell Time Domain Reflectometry (TDR) and Watermarks (WM) moisture sensors for their ability to estimate water content based on calibrated neutron probe measurements. The three sensors were in-situ tested under natural weather conditions over ...

  13. Method for the measurement of forest duff moisture content

    Treesearch

    Peter R. Robichaud; Roger D. Hungerford; David S. Gasvoda

    2000-01-01

    An apparatus and method for the moisture content measurement of compressible materials using pressure to firmly hold surface probes against the material to be measured. The apparatus uses moisture measurement circuitry employed in frequency domain impedance or time domain reflectometry devices to obtain moisture content readings from materials. These moisture content...

  14. Apparatus and method for the measurement of forest duff moisture content

    Treesearch

    Peter R. Robichaud; Roger D. Hungerford; David S. Gasvoda

    1999-01-01

    An apparatus and method for the moisture content measurement of compressible materials using pressure to firmly hold surface probes against the marerial to be measured. The apparatus uses moisture measurement circuitry employed in frequency domain impedance or time domain reflectometry devices to obtain moisture content readings from materials. These moisture content...

  15. A comparison of second order derivative based models for time domain reflectometry wave form analysis

    USDA-ARS?s Scientific Manuscript database

    Adaptive waveform interpretation with Gaussian filtering (AWIGF) and second order bounded mean oscillation operator Z square 2(u,t,r) are TDR analysis methods based on second order differentiation. AWIGF was originally designed for relatively long probe (greater than 150 mm) TDR waveforms, while Z s...

  16. Feasibility of using cone penetrometer truck (CPT) to install time domain reflectometry (TDR) and fiber optic slope failure detectors in pavement structures.

    DOT National Transportation Integrated Search

    2011-02-01

    A new method of cable installation using a heavy-duty Cone Penetration Test : (CPT) truck was developed and practiced successfully in this study. The coaxial and fiber : optic cables were pushed along with the cone rods by the hydraulic system integr...

  17. A TWO-PROBE METHOD FOR MEASURING WATER CONTENT OF THIN FOREST FLOOR LITTER LAYERS USING TIME DOMAIN REFLECTOMETRY

    EPA Science Inventory

    Few methods exist that allow non-destructive in situ measurement of the water content of forest floor litter layers (Oa,Oe, and Oi horizons). Continuous non-destructive measurement is needed in studies of ecosystem processes because of the relationship between physical structure ...

  18. Chemical and valence reconstruction at the surface of SmB6 revealed by means of resonant soft x-ray reflectometry

    NASA Astrophysics Data System (ADS)

    Zabolotnyy, V. B.; Fürsich, K.; Green, R. J.; Lutz, P.; Treiber, K.; Min, Chul-Hee; Dukhnenko, A. V.; Shitsevalova, N. Y.; Filipov, V. B.; Kang, B. Y.; Cho, B. K.; Sutarto, R.; He, Feizhou; Reinert, F.; Inosov, D. S.; Hinkov, V.

    2018-05-01

    Samarium hexaboride (SmB6), a Kondo insulator with mixed valence, has recently attracted much attention as a possible host for correlated topological surface states. Here, we use a combination of x-ray absorption and reflectometry techniques, backed up with a theoretical model for the resonant M4 ,5 absorption edge of Sm and photoemission data, to establish laterally averaged chemical and valence depth profiles at the surface of SmB6. We show that upon cleaving, the highly polar (001) surface of SmB6 undergoes substantial chemical and valence reconstruction, resulting in boron termination and a Sm3 + dominated subsurface region. Whereas at room temperature, the reconstruction occurs on a timescale of less than 2 h, it takes about 24 h below 50 K. The boron termination is eventually established, irrespective of the initial termination. Our findings reconcile earlier depth resolved photoemission and scanning tunneling spectroscopy studies performed at different temperatures and are important for better control of surface states in this system.

  19. Evaluating the solid electrolyte interphase formed on silicon electrodes: A comparison of ex situ X-ray photoelectron spectroscopy and in situ neutron reflectometry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Doucet, Mathieu; Browning, Jim; Baldwin, J. K.

    This work details the in situ characterization of the interface between a silicon electrode and an electrolyte using a linear fluorinated solvent molecule, 0.1 M lithium bis(trifluoromethanesulfonyl)imide (LiTFSI) in deuterated dimethyl perfluoroglutarate (d6-PF5M 2) (1.87 x 10 -2 mS/cm -1). The solid electrolyte interphase (SEI) composition and thickness determined via in situ neutron reflectometry (NR) and ex situ X-ray photoelectron spectroscopy (XPS) were compared. The data show that SEI expansion and contraction (breathing) during electrochemical cycling was observed via both techniques; however, ex situ XPS suggests that the SEI thickness increases during Si lithiation and decreases during delithiation, while inmore » situ NR suggests the opposite. The most likely cause of this discrepancy is the selective removal of SEI components (top 20 nm of the SEI) during the electrode rinse process, required to remove electrolyte residue prior to ex situ analysis, demonstrating the necessity of performing SEI characterizations in situ.« less

  20. Rapid screening of fatty acid alkyl esters in olive oils by time domain reflectometry.

    PubMed

    Berardinelli, Annachiara; Ragni, Luigi; Bendini, Alessandra; Valli, Enrico; Conte, Lanfranco; Guarnieri, Adriano; Toschi, Tullia Gallina

    2013-11-20

    The main aim of the present research is to assess the possibility of quickly screening fatty acid alkyl esters (FAAE) in olive oils using time domain reflectometry (TDR) and partial least-squares (PLS) multivariate statistical analysis. Eighteen virgin olive oil samples with fatty acid alkyl ester contents and fatty acid ethyl ester/methyl ester ratios (FAEE/FAME) ranging from 3 to 100 mg kg(-1) and from 0.3 to 2.6, respectively, were submitted to tests with time domain resolution of 1 ps. The results obtained in test set validation demonstrated that this new and fast analytical approach is able to predict FAME, FAEE, and FAME + FAEE contents with R(2) values of 0.905, 0.923, and 0.927, respectively. Further measurements on mixtures between olive oil and FAAE standards confirmed that the prediction is based on a direct influence of fatty acid alkyl esters on the TDR signal. The suggested technique appeared potentially suitable for monitoring one of the most important quality attribute of the olive oil in the extraction process.

  1. Analysis of biosurfaces by neutron reflectometry: From simple to complex interfaces

    DOE PAGES

    Junghans, Ann; Watkins, Erik B.; Barker, Robert D.; ...

    2015-03-16

    Because of its high sensitivity for light elements and the scattering contrast manipulation via isotopic substitutions, neutron reflectometry (NR) is an excellent tool for studying the structure of soft-condensed material. These materials include model biophysical systems as well as in situ living tissue at the solid–liquid interface. The penetrability of neutrons makes NR suitable for probing thin films with thicknesses of 5–5000 Å at various buried, for example, solid–liquid, interfaces [J. Daillant and A. Gibaud, Lect. Notes Phys. 770, 133 (2009); G. Fragneto-Cusani, J. Phys.: Condens. Matter 13, 4973 (2001); J. Penfold, Curr. Opin. Colloid Interface Sci. 7, 139 (2002)].more » Over the past two decades, NR has evolved to become a key tool in the characterization of biological and biomimetic thin films. Highlighted In the current report are some of the authors' recent accomplishments in utilizing NR to study highly complex systems, including in-situ experiments. Such studies will result in a much better understanding of complex biological problems, have significant medical impact by suggesting innovative treatment, and advance the development of highly functionalized biomimetic materials.« less

  2. Spaceborne GNSS reflectometry for ocean winds: First results from the UK TechDemoSat-1 mission

    NASA Astrophysics Data System (ADS)

    Foti, Giuseppe; Gommenginger, Christine; Jales, Philip; Unwin, Martin; Shaw, Andrew; Robertson, Colette; Roselló, Josep

    2015-07-01

    First results are presented for ocean surface wind speed retrieval from reflected GPS signals measured by the low Earth orbiting UK TechDemoSat-1 satellite (TDS-1). Launched in July 2014, TDS-1 provides the first new spaceborne Global Navigation Satellite System-Reflectometry (GNSS-R) data since the pioneering UK-Disaster Monitoring Mission (UK-DMC) experiment in 2003. Examples of onboard-processed delay-Doppler maps reveal excellent data quality for winds up to 27.9 m/s. Collocated Advanced Scatterometer (ASCAT) winds are used to develop and evaluate a wind speed algorithm based on signal-to-noise ratio (SNR) and the bistatic radar equation. For SNRs greater than 3 dB, wind speed is retrieved without bias and a precision around 2.2 m/s between 3 and 18 m/s even without calibration. Exploiting lower SNR signals, however, requires good knowledge of the antenna beam, platform attitude, and instrument gain setting. This study demonstrates the capabilities of low-cost, low-mass, and low-power GNSS-R receivers ahead of their launch on the NASA Cyclone GNSS (CYGNSS) constellation in 2016.

  3. Azimuth selection for sea level measurements using geodetic GPS receivers

    NASA Astrophysics Data System (ADS)

    Wang, Xiaolei; Zhang, Qin; Zhang, Shuangcheng

    2018-03-01

    Based on analysis of Global Positioning System (GPS) multipath signals recorded by a geodetic GPS receiver, GPS Reflectometry (GPS-R) has demonstrated unique advantages in relation to sea level monitoring. Founded on multipath reflectometry theory, sea level changes can be measured by GPS-R through spectral analysis of recorded signal-to-noise ratio data. However, prior to estimating multipath parameters, it is necessary to define azimuth and elevation angle mask to ensure the reflecting zones are on water. Here, a method is presented to address azimuth selection, a topic currently under active development in the field of GPS-R. Data from three test sites: the Kachemak Bay GPS site PBAY in Alaska (USA), Friday Harbor GPS site SC02 in the San Juan Islands (USA), and Brest Harbor GPS site BRST in Brest (France) are analyzed. These sites are located in different multipath environments, from a rural coastal area to a busy harbor, and they experience different tidal ranges. Estimates by the GPS tide gauges at azimuths selected by the presented method are compared with measurements from physical tide gauges and acceptable correspondence found for all three sites.

  4. Distributed strain measurement based on long-gauge FBG and delayed transmission/reflection ratiometric reflectometry for dynamic structural deformation monitoring.

    PubMed

    Nishiyama, Michiko; Igawa, Hirotaka; Kasai, Tokio; Watanabe, Naoyuki

    2015-02-10

    In this paper, we propose a delayed transmission/reflection ratiometric reflectometry (DTR(3)) scheme using a long-gauge fiber Bragg grating (FBG), which can be used for dynamic structural deformation monitoring of structures of between a few to tens of meters in length, such as airplane wings and helicopter blades. FBG sensors used for multipoint sensing generally employ wavelength division multiplexing techniques utilizing several Bragg central wavelengths; by contrast, the DTR(3) interrogator uses a continuous pulse array based on a pseudorandom number code and a long-gauge FBG utilizing a single Bragg wavelength and composed of simple hardware devices. The DTR(3) scheme can detect distributed strain at a 50 cm spatial resolution using a long-gauge FBG with a 100 Hz sampling rate. We evaluated the strain sensing characteristics of the long-gauge FBG when attached to a 2.5 m aluminum bar and a 5.5 m helicopter blade model, determining these structure natural frequencies in free vibration tests and their distributed strain characteristics in static tests.

  5. First Spaceborne GNSS-Reflectometry Observations of Hurricanes From the UK TechDemoSat-1 Mission

    NASA Astrophysics Data System (ADS)

    Foti, Giuseppe; Gommenginger, Christine; Srokosz, Meric

    2017-12-01

    We present the first examples of Global Navigation Satellite Systems-Reflectometry (GNSS-R) observations of hurricanes using spaceborne data from the UK TechDemoSat-1 (TDS-1) mission. We confirm that GNSS-R signals can detect ocean condition changes in very high near-surface ocean wind associated with hurricanes. TDS-1 GNSS-R reflections were collocated with International Best Track Archive for Climate Stewardship (IBTrACS) hurricane data, MetOp ASCAT A/B scatterometer winds, and two reanalysis products. Clear variations of GNSS-R reflected power (σ0) are observed as reflections travel through hurricanes, in some cases up to and through the eye wall. The GNSS-R reflected power is tentatively inverted to estimate wind speed using the TDS-1 baseline wind retrieval algorithm developed for low to moderate winds. Despite this, TDS-1 GNSS-R winds through the hurricanes show closer agreement with IBTrACS estimates than winds provided by scatterometers and reanalyses. GNSS-R wind profiles show realistic spatial patterns and sharp gradients that are consistent with expected structures around the eye of tropical cyclones.

  6. Advancing Wetlands Mapping and Monitoring with GNSS Reflectometry

    NASA Astrophysics Data System (ADS)

    Zuffada, Cinzia; Chew, Clara; Nghiem, Son V.; Shah, Rashmi; Podest, Erika; Bloom, A. Anthony; Koning, Alexandra; Small, Eric; Schimel, David; Reager, J. T.; Mannucci, Anthony; Williamson, Walton; Cardellach, Estel

    2016-08-01

    Wetland dynamics is crucial to address changes in both atmospheric methane (CH4) and terrestrial water storage. Yet, both spatial distribution and temporal variability of wetlands remain highly unconstrained despite the existence of remote sensing products from past and present satellite sensors. An innovative approach to mapping wetlands is offered by the Global Navigation Satellite System Reflectometry (GNSS-R), which is a bistatic radar concept that takes advantage of the ever increasing number of GNSS transmitting satellites to yield many randomly distributed measurements with broad-area global coverage and rapid revisit time. Hence, this communication presents the science motivation for mapping of wetlands and monitoring of their dynamics, and shows the relevance of the GNSS-R technique in this context, relative to and in synergy with other existing measurement systems. Additionally, the communication discusses results of our data analysis on wetlands in the Amazon, specifically from the initial analysis of satellite data acquired by the TechDemoSat-1 mission launched in 2014. Finally, recommendations are provided for the design of a GNSS-R mission specifically to address wetlands science issues.

  7. Enhanced ν-optical time domain reflectometry using gigahertz sinusoidally gated InGaAs/InP single-photon avalanche detector

    NASA Astrophysics Data System (ADS)

    Zhang, Xuping; Shi, Yuanlei; Shan, Yuanyuan; Sun, Zhenhong; Qiao, Weiyan; Zhang, Yixin

    2016-09-01

    Optical time domain reflectometry (OTDR) is one of the most successful diagnostic tools for nondestructive attenuation measurement of a fiber link. To achieve better sensitivity, spatial resolution, and avoid dead-zone in conversional OTDR, a single-photon detector has been introduced to form the photon-counting OTDR (ν-OTDR). We have proposed a ν-OTDR system using a gigahertz sinusoidally gated InGaAs/InP single-photon avalanche detector (SPAD). Benefiting from the superior performance of a sinusoidal gated SPAD on dark count probability, gating frequency, and gate duration, our ν-OTDR system has achieved a dynamic range (DR) of 33.4 dB with 1 μs probe pulse width after an equivalent measurement time of 51 s. This obtainable DR corresponds to a sensing length over 150 km. Our system has also obtained a spatial resolution of 5 cm at the end of a 5-km standard single-mode fiber. By employing a sinusoidal gating technique, we have improved the ν-OTDR spatial resolution and significantly reduced the measurement time.

  8. Temperature-strain discrimination in distributed optical fiber sensing using phase-sensitive optical time-domain reflectometry.

    PubMed

    Lu, Xin; Soto, Marcelo A; Thévenaz, Luc

    2017-07-10

    A method based on coherent Rayleigh scattering distinctly evaluating temperature and strain is proposed and experimentally demonstrated for distributed optical fiber sensing. Combining conventional phase-sensitive optical time-domain domain reflectometry (ϕOTDR) and ϕOTDR-based birefringence measurements, independent distributed temperature and strain profiles are obtained along a polarization-maintaining fiber. A theoretical analysis, supported by experimental data, indicates that the proposed system for temperature-strain discrimination is intrinsically better conditioned than an equivalent existing approach that combines classical Brillouin sensing with Brillouin dynamic gratings. This is due to the higher sensitivity of coherent Rayleigh scatting compared to Brillouin scattering, thus offering better performance and lower temperature-strain uncertainties in the discrimination. Compared to the Brillouin-based approach, the ϕOTDR-based system here proposed requires access to only one fiber-end, and a much simpler experimental layout. Experimental results validate the full discrimination of temperature and strain along a 100 m-long elliptical-core polarization-maintaining fiber with measurement uncertainties of ~40 mK and ~0.5 με, respectively. These values agree very well with the theoretically expected measurand resolutions.

  9. Tracking serum antibody response to viral antigens with arrayed imaging reflectometry

    NASA Astrophysics Data System (ADS)

    Mace, Charles R.; Rose, Robert C.; Miller, Benjamin L.

    2009-02-01

    Arrayed Imaging Reflectometry, or "AIR", is a new label-free technique for detecting proteins that relies on bindinginduced changes in the response of an antireflective coating on the surface of a silicon ship. Because the technique provides high sensitivity, excellent dynamic range, and readily integrates with standard silicon wafer processing technology, it is an exceptionally attractive platform on which to build systems for detecting proteins in complex solutions. In our early research, we used AIR chips bearing secreted receptor proteins from enteropathogenic E. coli to develop sensors for this pathogen. Recently, we have been exploring an alternative strategy: Rather than detecting the pathogen directly, can one immobilize antigens from a pathogen, and employ AIR to detect antibody responses to those antigens? Such a strategy would provide enhanced sensitivity for pathogen detection (as the immune system essentially amplifies the "signal" caused by the presence of an organism to which it responds), and would also potentially prove useful in the process of vaccine development. We describe herein preliminary results in the application of such a strategy to the detection of antibodies to human papillomavirus (HPV).

  10. Examining small molecule: HIV RNA interactions using arrayed imaging reflectometry

    NASA Astrophysics Data System (ADS)

    Chaimayo, Wanaruk; Miller, Benjamin L.

    2014-03-01

    Human Immunodeficiency Virus (HIV) has been the subject of intense research for more than three decades as it causes an uncurable disease: Acquired Immunodeficiency Syndrome, AIDS. In the pursuit of a medical treatment, RNAtargeted small molecules are emerging as promising targets. In order to understand the binding kinetics of small molecules and HIV RNA, association (ka) and dissociation (kd) kinetic constants must be obtained, ideally for a large number of sequences to assess selectivity. We have developed Aqueous Array Imaged Reflectometry (Aq-AIR) to address this challenge. Using a simple light interference phenomenon, Aq-AIR provides real-time high-throughput multiplex capabilities to detect binding of targets to surface-immobilized probes in a label-free microarray format. The second generation of Aq-AIR consisting of high-sensitivity CCD camera and 12-μL flow cell was fabricated. The system performance was assessed by real-time detection of MBNL1-(CUG)10 and neomycin B - HIV RNA bindings. The results establish this second-generation Aq-AIR to be able to examine small molecules binding to RNA sequences specific to HIV.

  11. Size effect in the spin glass magnetization of thin AuFe films as studied by polarized neutron reflectometry.

    PubMed

    Saoudi, M; Fritzsche, H; Nieuwenhuys, G J; Hesselberth, M B S

    2008-02-08

    We used polarized neutron reflectometry to determine the temperature dependence of the magnetization of thin AuFe films with 3% Fe concentration. We performed the measurements in a large magnetic field of 6 T in a temperature range from 295 to 2 K. For the films in the thickness range from 500 to 20 nm we observed a Brillouin-type behavior from 295 K down to 50 K and a constant magnetization of about 0.9 micro(B) per Fe atom below 30 K. However, for the 10 nm thick film we observed a Brillouin-type behavior down to 20 K and a constant magnetization of about 1.3 micro(B) per Fe atom below 20 K. These experiments are the first to show a finite-size effect in the magnetization of single spin-glass films in large magnetic fields. Furthermore, the ability to measure the deviation from the paramagnetic behavior enables us to prove the existence of the spin-glass state where other methods relying on a cusp-type behavior fail.

  12. Effect of temperature, high pressure and freezing/thawing of dry-cured ham slices on dielectric time domain reflectometry response.

    PubMed

    Rubio-Celorio, Marc; Garcia-Gil, Núria; Gou, Pere; Arnau, Jacint; Fulladosa, Elena

    2015-02-01

    Dielectric Time Domain Reflectometry (TDR) is a useful technique for the characterization and classification of dry-cured ham according to its composition. However, changes in the behavior of dielectric properties may occur depending on environmental factors and processing. The effect of temperature, high pressure (HP) and freezing/thawing of dry-cured ham slices on the obtained TDR curves and on the predictions of salt and water contents when using previously developed predictive models, was evaluated in three independent experiments. The results showed that at temperatures below 20 °C there is an increase of the predicted salt content error, being more important in samples with higher water content. HP treatment caused a decrease of the reflected signal intensity due to the major mobility of available ions promoting an increase of the predicted salt content. Freezing/thawing treatment caused an increase of the reflected signal intensity due to the microstructural damages and the loss of water and ions, promoting a decrease of the predicted salt content.

  13. Evaluating the solid electrolyte interphase formed on silicon electrodes: A comparison of ex situ X-ray photoelectron spectroscopy and in situ neutron reflectometry

    DOE PAGES

    Doucet, Mathieu; Browning, Jim; Baldwin, J. K.; ...

    2016-04-15

    This work details the in situ characterization of the interface between a silicon electrode and an electrolyte using a linear fluorinated solvent molecule, 0.1 M lithium bis(trifluoromethanesulfonyl)imide (LiTFSI) in deuterated dimethyl perfluoroglutarate (d6-PF5M 2) (1.87 x 10 -2 mS/cm -1). The solid electrolyte interphase (SEI) composition and thickness determined via in situ neutron reflectometry (NR) and ex situ X-ray photoelectron spectroscopy (XPS) were compared. The data show that SEI expansion and contraction (breathing) during electrochemical cycling was observed via both techniques; however, ex situ XPS suggests that the SEI thickness increases during Si lithiation and decreases during delithiation, while inmore » situ NR suggests the opposite. The most likely cause of this discrepancy is the selective removal of SEI components (top 20 nm of the SEI) during the electrode rinse process, required to remove electrolyte residue prior to ex situ analysis, demonstrating the necessity of performing SEI characterizations in situ.« less

  14. High-pressure and high-temperature neutron reflectometry cell for solid-fluid interface studies

    NASA Astrophysics Data System (ADS)

    Wang, P.; Lerner, A. H.; Taylor, M.; Baldwin, J. K.; Grubbs, R. K.; Majewski, J.; Hickmott, D. D.

    2012-07-01

    A new high pressure-temperature ( P - T Neutron Reflectometry (NR) cell developed at Los Alamos National Laboratory (LANL) is described that significantly extends the capabilities of solid/fluid interface investigations up to 200MPa ( ensuremath ˜ 30000 psi) and 200 ° C. The cell's simple aluminum construction makes it light and easy to operate while thinned neutron windows allow up to 74% neutron transmission. The wide-open neutron window geometry provides a maximum theoretical ensuremath Qz range of 0.31Å-1. Accurate T and P controls are integrated on the cell's control panel. Built-in powder wells provide the ability to saturate fluids with reactive solids, producing aqueous species and/or decomposing into gaseous phases. The cell is designed for samples up to 50.8mm in diameter and 10.0mm in thickness. An experiment investigating the high P - T corrosion behavior of aluminum on LANL's Surface ProfilE Analysis Reflectometer (SPEAR) is presented, demonstrating the functioning and capability of the cell. Finally, outlooks on high P - T NR applications and perspectives on future research are discussed.

  15. JGIXA - A software package for the calculation and fitting of grazing incidence X-ray fluorescence and X-ray reflectivity data for the characterization of nanometer-layers and ultra-shallow-implants

    NASA Astrophysics Data System (ADS)

    Ingerle, D.; Pepponi, G.; Meirer, F.; Wobrauschek, P.; Streli, C.

    2016-04-01

    Grazing incidence XRF (GIXRF) is a very surface sensitive, nondestructive analytical tool making use of the phenomenon of total external reflection of X-rays on smooth polished surfaces. In recent years the method experienced a revival, being a powerful tool for process analysis and control in the fabrication of semiconductor based devices. Due to the downscaling of the process size for semiconductor devices, junction depths as well as layer thicknesses are reduced to a few nanometers, i.e. the length scale where GIXRF is highly sensitive. GIXRF measures the X-ray fluorescence induced by an X-ray beam incident under varying grazing angles and results in angle dependent intensity curves. These curves are correlated to the layer thickness, depth distribution and mass density of the elements in the sample. But the evaluation of these measurements is ambiguous with regard to the exact distribution function for the implants as well as for the thickness and density of nanometer-thin layers. In order to overcome this ambiguity, GIXRF can be combined with X-ray reflectometry (XRR). This is straightforward, as both techniques use similar measurement procedures and the same fundamental physical principles can be used for a combined data evaluation strategy. Such a combined analysis removes ambiguities in the determined physical properties of the studied sample and, being a correlative spectroscopic method, also significantly reduces experimental uncertainties of the individual techniques. In this paper we report our approach to a correlative data analysis, based on a concurrent calculation and fitting of simultaneously recorded GIXRF and XRR data. Based on this approach we developed JGIXA (Java Grazing Incidence X-ray Analysis), a multi-platform software package equipped with a user-friendly graphic user interface (GUI) and offering various optimization algorithms. Software and data evaluation approach were benchmarked by characterizing metal and metal oxide layers on Silicon as well as Arsenic implants in Silicon. The results of the different optimization algorithms have been compared to test the convergence of the algorithms. Finally, simulations for Iron nanoparticles on bulk Silicon and on a W/C multilayer are presented, using the assumption of an unaltered X-ray Standing Wave above the surface.

  16. Transmission of isotropic light across a dielectric surface in two and three dimensions.

    NASA Technical Reports Server (NTRS)

    Allen, W. A.

    1973-01-01

    Average transmittance of polarized diffuse light across a dielectric surface is calculated in both two and three dimensions. The incident light in both cases is confined to an angular range measured from the surface normal. Limiting values in three dimensions correspond to known results for two cases, (1) normal incidence, and (2) diffuse light incident from a 180 deg cone. The two-dimensional formulation is solvable in terms of elliptic functions and incomplete elliptic integrals of the first, second, and third kinds. Results are displayed graphically for values of transmittances in excess of 0.9 associated with relative indices of refraction in the range m = 1.0 to m = 2.6.

  17. Note on the artefacts in SRIM simulation of sputtering

    NASA Astrophysics Data System (ADS)

    Shulga, V. I.

    2018-05-01

    The computer simulation program SRIM, unlike other well-known programs (MARLOWE, TRIM.SP, etc.), predicts non-zero values of the sputter yield at glancing ion bombardment of smooth amorphous targets and, for heavy ions, greatly underestimates the sputter yield at normal incidence. To understand the reasons for this, the sputtering of amorphous silicon bombarded with different ions was modeled here using the author's program OKSANA. Most simulations refer to 1 keV Xe ions, and angles of incidence cover range from 0 (normal incidence) to almost 90°. It has been shown that SRIM improperly simulates the initial stage of the sputtering process. Some other artefacts in SRIM calculations of sputtering are also revealed and discussed.

  18. Split-field FDTD method for oblique incidence study of periodic dispersive metallic structures.

    PubMed

    Baida, F I; Belkhir, A

    2009-08-15

    The study of periodic structures illuminated by a normally incident plane wave is a simple task that can be numerically simulated by the finite-difference time-domain (FDTD) method. On the contrary, for off-normal incidence, a widely modified algorithm must be developed in order to bypass the frequency dependence appearing in the periodic boundary conditions. After recently implementing this FDTD algorithm for pure dielectric materials, we here extend it to the study of metallic structures where dispersion can be described by analytical models. The accuracy of our code is demonstrated through comparisons with already-published results in the case of 1D and 3D structures.

  19. The dynamics of energy and charge transfer in low and hyperthermal energy ion-solid interactions

    NASA Astrophysics Data System (ADS)

    Ray, Matthew Preston

    The energy and charge transfer dynamics for low and hyperthermal energy (10 eV to 2 keV) alkali and noble gas ions impacting noble metals as a function of incident energy, species and scattering geometry has been studied. The experiments were performed in an ultra-high vacuum scattering chamber attached to a low and hyperthermal energy beamline. The energy transfer was measured for K+ scattered from a Ag(001) surface along the [110] crystalline direction at a fixed laboratory angle of 90°. It was found that as the incident energy is reduced from 100 to 10 eV, the normalized scattered energy increased. Previous measurements have shown a decrease in the normalized energy as the incident ion energy is reduced due to an attractive image force. Trajectory analysis of the data using a classical scattering simulation revealed that instead of undergoing sequential binary collisions as in previous studies, the ion scatters from two surface atoms simultaneously leading to an increased normalized energy. Additionally, charge transfer measurements have been performed for Na + scattering from Ag(001) along the [110] crystalline direction at a fixed laboratory angle of 70°. It was found that over the range of energies used (10 eV to 2 keV), the neutralization probability of the scattered ions varied from ˜30% to ˜70% depending on the incident velocity, consistent with resonant charge transfer. A fully quantum mechanical model that treats electrons independently accurately reproduces the observed data. Measurements of electron-hole pair excitations were used to explore the pathways which a solid uses to dissipate the energy imparted by the incident ion beam. Ultrathin film (10 nm) metal-oxide-semiconductor (Au/SiO2/n-Si) devices were used to detect the electron-hole pairs for cases when the ion deposited all of its translational energy into the solid. The incident ions were incident at an angle normal to the surface of the device to maximize energy deposition and consequently electron-hole pair production. The rectifying metal-oxide-semiconductor device separates the electrons from the holes, allowing a current associated with electron-hole pair production to be measured. In these experiments a number of ion species (He+, Li+ , Ar+, K+) were made incident on multiple devices and the incident energy ranged from 100 eV to 2 keV. It was found that electron-hole pair production increased with incident ion velocity consistent with a kinetic electron excitation model where the electrons in the metal are partially confined to the surface.

  20. Progress Report on the GROWTH (GNSS Reflectometry for Ocean Waves, Tides, and Height) Research Project

    NASA Astrophysics Data System (ADS)

    Kitazawa, Y.; Ichikawa, K.; Akiyama, H.; Ebinuma, T.; Isoguchi, O.; Kimura, N.; Konda, M.; Kouguchi, N.; Tamura, H.; Tomita, H.; Yoshikawa, Y.; Waseda, T.

    2016-12-01

    Global Navigation Satellite Systems (GNSS), such as GPS is a system of satellites that provide autonomous geo-spatial positioning with global coverage. It allows small electronic receivers to determine their location to high precision using radio signals transmitted from satellites, GNSS reflectometry (GNSS-R) involves making measurements from the reflections from the Earth of navigation signals from GNSS satellites. Reflected signals from sea surface are considered that those are useful to observe sea state and sea surface height. We have started a research program for GNSS-R applications on oceanographic observations under the contract with MEXT (Ministry of Education Culture, Sports, Science and Technology, JAPAN) and launched a Japanese research consortium, GROWTH (GNSS Reflectometry for Ocean Waves, Tides, and Height). It is aiming to evaluate the capabilities of GNSS-R observations for oceanographic phenomena with different time scales, such as ocean waves (1/10 to tens of seconds), tides (one or half days), and sea surface dynamic height (a few days to years). In situ observations of ocean wave spectrum, wind speed vertical profile, and sea surface height will be quantitatively compared with equivalent estimates from simultaneous GNSS-R measurements. The GROWTH project will utilize different types of observation platforms; marine observation towers (about 20 m height), multi-copters (about 100 to 150 m height), and much higher-altitude CYGNSS data. Cross-platform data, together with in situ oceanographic observations, will be compared after adequate temporal averaging that accounts differences of the footprint sizes and temporal and spatial scales of oceanographic phenomena. This paper will provide overview of the GROWTH project, preliminary test results, obtained by the multi-sensor platform at observation towers, suggest actual footprint sizes and identification of swell. Preparation status of a ground station which will be supplied to receive CYGNSS data at Japan, is also reported. Compatibility tests to CYGNSS data and refurbishment of the ground station were completed.

  1. Assessment of GPS Reflectometry from TechDemoSat-1 for Scatterometry and Altimetry Applications

    NASA Astrophysics Data System (ADS)

    Shah, R.; Hajj, G. A.

    2015-12-01

    The value of GPS reflectometry for scatterometry and altimetry applications has been a topic of investigation for the past two decades. TechDemoSat-1 (TDS-1), a technology demonstration satellite launched in July of 2014, with an instrument to collect GPS reflections from 4 GPS satellites simultaneously, provide the first extensive data that allows for validation and evaluation of GPS reflectometry from space against more established techniques. TDS-1 uses a high gain (~13 dBi) L1 antenna pointing 6 degrees off nadir with a 60ohalf-beam width. Reflected GPS L1 signals are processed into Delay Doppler Maps (DDMs) inside the receiver and made available (through Level-1b) along with metadata describing the bistatic geometry, antenna gain, etc., on a second-by-second basis for each of the 4 GPS tracks recorded at any given time. In this paper we examine level-1b data from TDS-1 for thousands of tracks collected over the span of Jan.-Feb., 2015. This data corresponds to reflections from various types of surfaces throughout the globe including ice, deserts, forests, oceans, lakes, wetlands, etc. Our analysis will consider how the surface type manifests itself in the DDMs (e.g., coherence vs. non-coherence reflection) and derivable physical quantities. We will consider questions regarding footprint resolution, waveform rise time and corresponding bistatic range accuracy, and level of precision for altimetry (sea surface height) and scatterometry (significant wave height and sea surface wind). Tracks from TDS-1 that coincide with Jason-1 or 2 tracks will be analyzed, where the latter can be used as truth for comparison and validation. Where coincidences are found, vertical delay introduced by the media as measured by Jason will be mapped to bistatic propagation path to correct for neutral atmospheric and ionospheric delays.

  2. MHD Wave Propagation at the Interface Between Solar Chromosphere and Corona

    NASA Astrophysics Data System (ADS)

    Huang, Y.; Song, P.; Vasyliunas, V. M.

    2017-12-01

    We study the electromagnetic and momentum constraints at the solar transition region which is a sharp layer interfacing between the solar chromosphere and corona. When mass transfer between the two domains is neglected, the transition region can be treated as a contact discontinuity across which the magnetic flux is conserved and the total forces are balanced. We consider an Alfvénic perturbation that propagates along the magnetic field incident onto the interface from one side. In order to satisfy the boundary conditions at the transition region, only part of the incident energy flux is transmitted through and the rest is reflected. Taking into account the highly anisotropic propagation of waves in magnetized plasmas, we generalize the law of reflection and specify Snell's law for each of the three wave MHD modes: incompressible Alfvén mode and compressible fast and slow modes. Unlike conventional optical systems, the interface between two magnetized plasmas is not rigid but can be deformed by the waves, allowing momentum and energy to be transferred by compression. With compressible modes included, the Fresnel conditions need substantial modification. We derive Fresnel conditions, reflectivities and transmittances, and mode conversion for incident waves propagating along the background magnetic field. The results are well organized when the incident perturbation is decomposed into components in and normal to the incident plane (containing the background magnetic field and the normal direction of the interface). For a perturbation normal to the incident plane, both transmitted and reflected perturbations are incompressible Alfvén mode waves. For a perturbation in the incident plane, they can be compressible slow and fast mode waves which may produce ripples on the transition region.

  3. An analysis of the surface-normal coupling efficiency of a metal grating coupler embedded in a Scotch tape optical waveguide

    NASA Astrophysics Data System (ADS)

    Barrios, Carlos Angulo; Canalejas-Tejero, Víctor

    2017-01-01

    The coupling efficiency at normal incidence of recently demonstrated aluminum grating couplers integrated in flexible Scotch tape waveguides has been analyzed theoretically and experimentally. Finite difference time domain (FDTD) and rigorously coupled wave analysis (RCWA) methods have been used to optimize the dimensions (duty cycle and metal thickness) of Scotch tape-embedded 1D Al gratings for maximum coupling at 635 nm wavelength. Good dimension and tape refractive index tolerances are predicted. FDTD simulations reveal the incident beam width and impinging position (alignment) values that avoid rediffraction and thus maximize the coupling efficiency. A 1D Al diffraction grating integrated into a Scotch tape optical waveguide has been fabricated and characterized. The fabrication process, based on pattern transfer, has been optimized to allow complete Al grating transfer onto the Scotch tape waveguide. A maximum coupling efficiency of 20% for TM-polarized normal incidence has been measured, which is in good agreement with the theoretical predictions. The measured coupling efficiency is further increased up to 28% for TM polarization under oblique incidence. Temperature dependence measurements have been also achieved and related to the simulations results and fabrication procedure.

  4. Investigation of Adhesive Bond Cure Conditions using Nonlinear Ultrasonic Methods

    NASA Technical Reports Server (NTRS)

    Berndt, Tobias P.; Green, Robert E., Jr.

    1999-01-01

    The objective of this presentation is to investigate various cure conditions of adhesive bonds using nonlinear ultrasonic methods with water coupling. Several samples were used to obtain normal incidence, oblique incidence, and wave mixing.

  5. On the tunability of quality-factor for optical Tamm plasmon modes

    NASA Astrophysics Data System (ADS)

    Kumar, Samir; Das, Ritwick

    2017-09-01

    We present a comprehensive investigation to ascertain the impact of gold and silver films on modifying the quality-factor (Q-factor) of optical Tamm-plasmon (OTP) resonance in a metal-distributed Bragg reflector (M-DBR) geometry. Here, OTP mode is excited using direct incidence of white-light-source at normal incidence as well as oblique incidence on M-DBR geometry. The lifetime of OTP in gold and silver deposited films on DBR mirror was determined from OTP resonance linewidth. The lifetime and the Q-factor of OTP modes are found to depend on DBR bilayers, metal film thickness as well as on different plasmon active metals. This finding would facilitate tuning the Q-factor and consequently, the lifetime of OTP modes for various applications in all-optical switches and modulators. In addition, we discuss the spectral characteristics of OTP modes excited using normal and oblique incident of source.

  6. A simple model of space radiation damage in GaAs solar cells

    NASA Technical Reports Server (NTRS)

    Wilson, J. W.; Stith, J. J.; Stock, L. V.

    1983-01-01

    A simple model is derived for the radiation damage of shallow junction gallium arsenide (GaAs) solar cells. Reasonable agreement is found between the model and specific experimental studies of radiation effects with electron and proton beams. In particular, the extreme sensitivity of the cell to protons stopping near the cell junction is predicted by the model. The equivalent fluence concept is of questionable validity for monoenergetic proton beams. Angular factors are quite important in establishing the cell sensitivity to incident particle types and energies. A fluence of isotropic incidence 1 MeV electrons (assuming infinite backing) is equivalent to four times the fluence of normal incidence 1 MeV electrons. Spectral factors common to the space radiations are considered, and cover glass thickness required to minimize the initial damage for a typical cell configuration is calculated. Rough equivalence between the geosynchronous environment and an equivalent 1 MeV electron fluence (normal incidence) is established.

  7. Four-parameter model for polarization-resolved rough-surface BRDF.

    PubMed

    Renhorn, Ingmar G E; Hallberg, Tomas; Bergström, David; Boreman, Glenn D

    2011-01-17

    A modeling procedure is demonstrated, which allows representation of polarization-resolved BRDF data using only four parameters: the real and imaginary parts of an effective refractive index with an added parameter taking grazing incidence absorption into account and an angular-scattering parameter determined from the BRDF measurement of a chosen angle of incidence, preferably close to normal incidence. These parameters allow accurate predictions of s- and p-polarized BRDF for a painted rough surface, over three decades of variation in BRDF magnitude. To characterize any particular surface of interest, the measurements required to determine these four parameters are the directional hemispherical reflectance (DHR) for s- and p-polarized input radiation and the BRDF at a selected angle of incidence. The DHR data describes the angular and polarization dependence, as well as providing the overall normalization constraint. The resulting model conserves energy and fulfills the reciprocity criteria.

  8. Association of triglyceride-to-high density lipoprotein cholesterol ratio to cardiorespiratory fitness in men.

    PubMed

    Vega, Gloria Lena; Grundy, Scott M; Barlow, Carolyn E; Leonard, David; Willis, Benjamin L; DeFina, Laura F; Farrell, Stephen W

    Both triglyceride-to-high density lipoprotein cholesterol (TG/HDL-C) and cardiorespiratory fitness (CRF) impart risk for all-cause morbidity and mortality independently of conventional risk factors. To determine prevalence and/or incidence of high TG/HDL-C ratio in men with low CRF. Clinical characteristics and CRF were used to determine prevalence of a TG/HDL-C ratio ≥ 3.5 (high ratio) in 13,954 men of the Cooper Center Longitudinal Study. High-ratio conversion was determined in 10,424 men with normal baseline TG/HDL-C ratio. Hazard ratio (HR) of incident high TG/HDL-C was adjusted for age and waist girth. Men with low CRF had the highest prevalence of a high TG/HDL-C ratio. In the population with normal TG/HDL-C, age-adjusted HR of incident high TG/HDL-C ratio was 2.77 times higher in men with lowest CRF than in those with highest CRF. Incidence of conversion of normal to high ratio was 5.5% per year in low CRF population, compared with 1.7% in high CRF subjects. Incidence HR was independent of waist girth. Men who converted from normal to high TG/HDL-C ratio during the follow-up period had increased number of metabolic risk factors and a higher prevalence of metabolic syndrome. Men who did not convert to a high TG/HDL-C ratio retained a low prevalence of metabolic syndrome risk factors. A high TG/HDL-C ratio is common in men with low CRF. Metabolic syndrome also is common among those with a high ratio. Copyright © 2016 National Lipid Association. All rights reserved.

  9. The association between eGFR in the normal or mildly impaired range and incident cadiovascular disease: Age and sex analysis.

    PubMed

    Eisen, Alon; Porter, Avital; Hoshen, Moshe; Balicer, Ran D; Reges, Orna; Rabi, Yardena; Leibowitz, Morton; Iakobishvili, Zaza; Hasdai, David

    2018-05-14

    Worse renal function, even in the normal or mildly impaired range, is associated with incident cardiovascular disease (CVD). Whether this association exists in both sexes across all ages is not known. A population based cohort of individuals >22 years with no prior CVD and with an eGFR 60-130 ml/min/1.73 m 2 . eGFR was calculated using the CKD-EPI formula. Incident CVD was defined as either myocardial infarction, unstable angina pectoris, coronary revascularization, or cerebrovascular event. Incident CVD was examined separately in men and women in 3 age-groups (young, 22-40 years; middle-aged, 41-60 years; and elderly, ≥61 years), during a median follow-up of 96.0 months. Among 1,341,400 individuals (57% women, mean age 49.2 ± 16.6 years), men had more incident CVD as compared to women (34,968 vs. 23,515 total incident CVD) in all age-groups (0.6% vs. 0.2% in young; 6.2% vs. 2.0% in middle-aged; 13.4% vs. 8.4% in elderly, respectively). After adjustment for CVD risk factors, an increment of 10 units in eGFR was independently associated with a decrease of 5.4%, 3.4% and 5.4% in incident CVD in young, middle-aged and elderly men (p < 0.001 for each) and a decrease of 6.3%, 3.4% and 6.8% in the same age-groups in women (p < 0.001 for each). There was no significant age-sex interaction in the association between eGFR and incident CVD. Although incident CVD differs in men and women, as well as in different age-groups, a higher eGFR even in the normal or mildly impaired range is associated with lesser incident CVD in men and women of all ages. Copyright © 2018 European Federation of Internal Medicine. Published by Elsevier B.V. All rights reserved.

  10. Method for characterization of a spherically bent crystal for K.alpha. X-ray imaging of laser plasmas using a focusing monochromator geometry

    DOEpatents

    Kugland, Nathan; Doeppner, Tilo; Glenzer, Siegfried; Constantin, Carmen; Niemann, Chris; Neumayer, Paul

    2015-04-07

    A method is provided for characterizing spectrometric properties (e.g., peak reflectivity, reflection curve width, and Bragg angle offset) of the K.alpha. emission line reflected narrowly off angle of the direct reflection of a bent crystal and in particular of a spherically bent quartz 200 crystal by analyzing the off-angle x-ray emission from a stronger emission line reflected at angles far from normal incidence. The bent quartz crystal can therefore accurately image argon K.alpha. x-rays at near-normal incidence (Bragg angle of approximately 81 degrees). The method is useful for in-situ calibration of instruments employing the crystal as a grating by first operating the crystal as a high throughput focusing monochromator on the Rowland circle at angles far from normal incidence (Bragg angle approximately 68 degrees) to make a reflection curve with the He-like x-rays such as the He-.alpha. emission line observed from a laser-excited plasma.

  11. Working group organizational meeting

    NASA Technical Reports Server (NTRS)

    1982-01-01

    Scene radiation and atmospheric effects, mathematical pattern recognition and image analysis, information evaluation and utilization, and electromagnetic measurements and signal handling are considered. Research issues in sensors and signals, including radar (SAR) reflectometry, SAR processing speed, registration, including overlay of SAR and optical imagery, entire system radiance calibration, and lack of requirements for both sensors and systems, etc. were discussed.

  12. An Investigation of the Distribution of Radiation Scattered by Optical Surfaces

    DTIC Science & Technology

    1975-08-01

    Profile Inversion Workshop, Ames Research Center, Moffett Field, California, L. Colin, ed., pp. 6-34 to 6-37 ( NASA TM X-62, 150). (Available from th...Surface EM Scattering Solutions," IEEE Trans. AP-21:393-396. Judd, D. B., 1967, "Terms, Definitions, and Symbols in Reflectometry ," J. Opt. Soc. Am. 57:445

  13. Quantum nondemolition readout using a Josephson bifurcation amplifier

    NASA Astrophysics Data System (ADS)

    Boulant, N.; Ithier, G.; Meeson, P.; Nguyen, F.; Vion, D.; Esteve, D.; Siddiqi, I.; Vijay, R.; Rigetti, C.; Pierre, F.; Devoret, M.

    2007-07-01

    We report an experiment on the determination of the quantum nondemolition (QND) nature of a readout scheme of a quantum electrical circuit. The circuit is a superconducting quantum bit measured by microwave reflectometry using a Josephson bifurcation amplifier. We perform a series of two subsequent measurements, record their values and correlation, and quantify the QND character of this readout.

  14. Metal/dielectric/metal sandwich film for broadband reflection reduction

    PubMed Central

    Jen, Yi-Jun; Lakhtakia, Akhlesh; Lin, Meng-Jie; Wang, Wei-Hao; Wu, Huang-Ming; Liao, Hung-Sheng

    2013-01-01

    A film comprising randomly distributed metal/dielectric/metal sandwich nanopillars with a distribution of cross-sectional diameters, displayed extremely low reflectance over the blue-to-red regime, when coated on glass and illuminated normally. When it is illuminated by normally incident light, this sandwich film (SWF) has a low extinction coefficient, its phase thickness is close to a negative wavelength in the blue-to-red spectral regime, and it provides weakly dispersive forward and backward impedances, so that reflected waves from the two faces of the SWF interfere destructively. Broadband reflection-reduction, over a wide range of incidence angles and regardless of the polarization state of the incident light, was observed when the SWF was deposited on polished silicon. PMID:23591704

  15. Interferometry On Grazing Incidence Optics

    NASA Astrophysics Data System (ADS)

    Geary, Joseph; Maeda, Riki

    1988-08-01

    A preliminary interferometric procedure is described showing potential for obtaining surface figure error maps of grazing incidence optics at normal incidence. The latter are found in some laser resonator configurations, and in Wolter type X-ray optics. The procedure makes use of cylindrical wavefronts and error subtraction techniques over subapertures. The surface error maps obtained will provide critical information to opticians in the fabrication process.

  16. Interferometry on grazing incidence optics

    NASA Astrophysics Data System (ADS)

    Geary, Joseph M.; Maeda, Riki

    1987-12-01

    An interfeormetric procedure is described that shows potential for obtaining surface figure error maps of grazing incidence optics at normal incidence. Such optics are found in some laser resonator configurations and in Wolter-type X-ray optics. The procedure makes use of cylindrical wavefronts and error subtraction techniques over subapertures. The surface error maps obtained will provide critical information to opticians for the fabrication process.

  17. Effect of magnesium sulfate nebulization on the incidence of postoperative sore throat.

    PubMed

    Yadav, Monu; Chalumuru, Nitish; Gopinath, Ramachandran

    2016-01-01

    Postoperative sore throat (POST) is a well-recognized complication after general anesthesia (GA). Numerous nonpharmacological and pharmacological measures have been used for attenuating POST with variable success. The present study was conducted to compare the efficiency of preoperative nebulization of normal saline and magnesium sulfate in reducing the incidence of POST following GA. Following institutional ethical committee approval and written informed consent, a prospective randomized double-blinded study was conducted in 100 cases divided into two equal groups. Patients included in the study were of either gender belonging to American Society of Anesthesiologist (ASA) status 1 or 2 undergoing elective surgery of approximately 2 h or more duration requiring tracheal intubation. Patients in Group A are nebulized with 3 ml of normal saline and the patients in Group B are nebulized with 3 ml of 225 mg isotonic nebulized magnesium sulfate for 15 min, 5 min before induction of anesthesia. The incidence of POST at rest and on swallowing and any undue complaints at 0, 2, 4, and 24 h in the postoperative period are evaluated. There is no significant difference in POST at rest during 0(th), 2(nd) and 4(th) h between normal saline and MgSO4. Significant difference is seen at 24(th) h, where MgSO4 lessens POST. There is no significant difference in POST on swallowing during 0(th) and 2(nd) h between normal saline and MgSO4. Significant difference is seen at 4(th) h, where MgSO4 has been shown to lessen POST. MgSO4 significantly reduces the incidence of POST compared to normal saline.

  18. Angiotensin converting enzyme genotype and chronic allograft nephropathy in protocol biopsies.

    PubMed

    Hueso, Miguel; Alía, Pedro; Moreso, Francesc; Beltrán-Sastre, Violeta; Riera, Luis; González, Carlota; Navarro, Miguel Angel; Grinyó, Josep Maria; Navarro, Estanis; Serón, Daniel

    2004-08-01

    Genotype DD of the angiotensin-converting enzyme (ACE) is not associated with an increased incidence of native renal diseases, although it could modulate progression to renal failure in patients who already display chronic lesions. Because its role in renal allograft degeneration is not well characterized, whether ACE genotype was associated with the prevalence of chronic allograft nephropathy (CAN) was studied, in a group of protocol biopsies from 180 patients, or with the incidence of CAN in 152 patients with at least two sequential biopsies. As a control group, ACE genotype was also studied in 41 donors and 72 healthy subjects. For analyzing the influence of ACE genotype in graft survival, patients were grouped into six categories (II-normal biopsy, ID-normal, DD-normal, II-CAN, ID-CAN and DD-CAN). Finally, relative renal ACE mRNA levels were measured in 67 cases by real-time PCR using the delta threshold cycle method. ACE-DD genotype was more frequent in patients who received a transplant than in control subjects (43.3% versus 30.1%, P = 0.026), but prevalence (DD = 42.7% versus non-DD = 42.2%) or incidence (DD = 24.6% versus non-DD = 29.9%) of CAN was not different regarding recipient ACE genotype. Furthermore, patients with the ACE-DD genotype and CAN had the poorest graft survival (II-normal = 100%, ID-normal = 91%, DD-normal = 84%, II-CAN = 100%, ID-CAN = 66%, and DD-CAN = 36%; P = 0.034) and higher ACE mRNA levels than non-DD and CAN (DD = -3.36 +/- 2.35 versus non-DD = -5.65 +/- 1.72-fold in ACE copies; P = 0.012). It is concluded that ACE-DD genotype is not associated with an increased prevalence or incidence of CAN but is actually associated with higher ACE mRNA levels and poorer graft survival in patients who already display CAN.

  19. Observations of Rotation Reversal and Fluctuation Hysteresis in Alcator C-Mod L-Mode Plasmas

    NASA Astrophysics Data System (ADS)

    Cao, N. M.; Rice, J. E.; White, A. E.; Baek, S. G.; Creely, A. J.; Ennever, P. C.; Hubbard, A. E.; Hughes, J. W.; Irby, J.; Rodriguez-Fernandez, P.; Chilenski, M. A.; Diamond, P. H.; Reinke, M. L.; Alcator C-Mod Team

    2017-10-01

    Intrinsic core toroidal rotation in Alcator C-Mod L-mode plasmas has been observed to spontaneously reverse direction when the minimum value of the normalized collisionality ν*, crosses around 0.4. In Ohmic plasmas, the rotation is co-current in the low density linear Ohmic confinement (LOC) regime and counter-current in the higher density saturated Ohmic confinement (SOC) regime. The reversal manifests a hysteresis loop in ν*, where the critical collisionalities for the forward and reverse transitions differ by 10-15%. Temperature and density profiles of the two rotation states are observed to be indistinguishable to within experimental error estimated with Gaussian process regression. However, qualitative differences between the two rotation states are observed in fluctuation spectra, including the broadening of reflectometry spectra and, under certain conditions, the appearance of high-k features in phase contrast imaging (PCI) spectra (kθρs up to 1). These results suggest that the turbulent state can decouple from local profiles, and that turbulent self-regulation may play a role in the LOC/SOC transition. This work is supported by the US DOE under Grant DE-FC02-99ER54512 (C-Mod).

  20. IRP Stage 2 Remedial Investigation/Feasibility Study, Appendices A through K and M through R, for BOMARC Missile Site, McGuire AFB, New Jersey.

    DTIC Science & Technology

    1992-05-26

    have been no direct measurements of increased cancer incidence rates for low-level radiation exposures. Consequently, these estimates are relevant only...populations rather than to individuals. They are included in this table only for comparison to normal cancer incidence rates . The natural incidence rate for all...fatal cancers exceeds 2500 cancers/year per million persons (NAS, 1990). In the United Sates, the natural incidence rate for liver cancers is about

  1. Incidence of disorders of spermatogenesis in middle aged finnish men, 1981-91: two necropsy series.

    PubMed Central

    Pajarinen, J.; Laippala, P.; Penttila, A.; Karhunen, P. J.

    1997-01-01

    OBJECTIVE: To investigate if the incidence of disorders of spermatogenesis and testicular tissue morphology have changed in middle aged Finnish men over 10 years. DESIGN: Two necropsy series completed in 1981 and in 1991. SETTING: Department of Forensic Medicine, University of Helsinki, Finland. SUBJECTS: 528 men, aged 35 to 69 years, subjected to medicolegal necropsy. MAIN OUTCOME MEASURES: Scoring of spermatogenesis and morphometric analysis of testicular tissue components. Individual risk factors for testicular disorders obtained by postmortem blind interviews with acquaintances. RESULTS: Normal spermatogenesis was found in 41.7% of the men (mean age 53.1 years). Between 1981 and 1991, the ratio of normal spermatogenesis decreased significantly (odds ratio 3.5; 95% confidence interval 2.5 to 5.1) from 56.4% to 26.9%, with a parallel increase in the incidence of partial and complete spermatogenic arrest (2.1; 1.4 to 2.9 and 2.9; 1.7 to 5.0, respectively). During this period, the size of seminiferous tubules decreased, the amount of fibrotic tissue increased, and the weight of testicles decreased significantly. Alterations in testicular characteristics over time could not be explained by changes in body mass index, smoking, alcohol drinking, or exposure to drugs. CONCLUSIONS: The incidence of normal spermatogenesis decreased among middle aged Finnish men from 1981 to 1991, and the incidence of disorders of spermatogenesis and pathological alterations in testicles increased. Deteriorating spermatogenesis may thus be one important factor in the explanation of declining sperm counts observed worldwide. PMID:9001473

  2. Reflectivity of a disordered monolayer estimated by graded refractive index and scattering models.

    PubMed

    Diamant, Ruth; Garcí-Valenzuela, Augusto; Fernández-Guasti, Manuel

    2012-09-01

    Reflectivity of a random monolayer, consisting of transparent spherical particles, is estimated using a graded refractive index model, an effective medium approach, and two scattering models. Two cases, a self-standing film and one with a substrate, are considered. Neither the surrounding medium nor the substrate are absorbing materials. Results at normal incidence, with different particle sizes, covering ratios and refractive indexes, are compared. The purpose of this work is to find under which circumstances, for reflectivity at normal incidence, a particle monolayer behaves as a graded refractive index film.

  3. Two normal incidence collimators designed for the calibration of the extreme ultraviolet explorer

    NASA Technical Reports Server (NTRS)

    Jelinsky, Sharon R.; Welsh, Barry; Jelinsky, Patrick; Spiller, Eberhard

    1988-01-01

    Two Dall-Kirkham, normal incidence collimators have been designed to calibrate the imaging properties of the Extreme Ultraviolet Explorer over the wavelength region from 114 to 2000 A. The mirrors of the short-wavelength, 25-cm diameter collimator are superpolished Zerodur which have been multilayer coated for optimal reflectivity at 114 A. The mirrors of the long-wavelength, 41.25-cm diameter collimator are gold coated Zerodur for high reflectance above 300 A. The design, performance, and future use of these collimators in the extreme ultra-violet is discussed.

  4. Nanopatterning of metal-coated silicon surfaces via ion beam irradiation: Real time x-ray studies reveal the effect of silicide bonding

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    El-Atwani, Osman; Birck Nanotechnology Center, Purdue University, West Lafayette, Indiana 47907; Gonderman, Sean

    We investigated the effect of silicide formation on ion-induced nanopatterning of silicon with various ultrathin metal coatings. Silicon substrates coated with 10 nm Ni, Fe, and Cu were irradiated with 200 eV argon ions at normal incidence. Real time grazing incidence small angle x-ray scattering (GISAXS) and x-ray fluorescence (XRF) were performed during the irradiation process and real time measurements revealed threshold conditions for nanopatterning of silicon at normal incidence irradiation. Three main stages of the nanopatterning process were identified. The real time GISAXS intensity of the correlated peaks in conjunction with XRF revealed that the nanostructures remain for amore » time period after the removal of the all the metal atoms from the sample depending on the binding energy of the metal silicides formed. Ex-situ XPS confirmed the removal of all metal impurities. In-situ XPS during the irradiation of Ni, Fe, and Cu coated silicon substrates at normal incidence demonstrated phase separation and the formation of different silicide phases that occur upon metal-silicon mixing. Silicide formation leads to nanostructure formation due the preferential erosion of the non-silicide regions and the weakening of the ion induced mass redistribution.« less

  5. Neurologic Damage and Behavior Disorder in Rubella Children.

    ERIC Educational Resources Information Center

    Chess, Stella; Fernandez, Paulina

    1980-01-01

    A longitudinal study of 214 rubella deaf children (13 to 14 years old) revealed a low incidence (10%) of neurologica damage among those with normal intelligence, but a high incidence (51% to 70%) among those who were mentally retarded or blind. (Author)

  6. The prevalence of lumbar spondylolysis in young children: a retrospective analysis using CT.

    PubMed

    Lemoine, Thibaut; Fournier, Joseph; Odent, Thierry; Sembély-Taveau, Catherine; Merenda, Pauline; Sirinelli, Dominique; Morel, Baptiste

    2018-05-01

    Although lumbar spondylolysis is encountered in general population with an incidence estimated to be 3-10%, limited information is available for children. The aim of the study is to determine the prevalence of spondylolysis according to associated vertebral bony malformation and spinopelvic parameters in children under eight requiring CT evaluation for unrelated lumbar conditions. Seven hundred and seventeen abdominal and pelvic multi-detector CT scans were obtained in patients under 8 years of age were reviewed. Two board certificated radiologists and two resident radiologists retrospectively evaluated CT scans for lumbar spondylolysis and associated malformations. Pelvic incidence and spondylolisthesis were reported. Our analysis included 717 CT scans in 532 children (259 girls and 273 boys). Twenty-five cases of spondylolysis were diagnosed (16 bilateral and 9 unilateral, 64 and 36%, respectively) in 14 boys (56%) and 11 girls (44%), associating with 12 grade I spondylolisthesis. The mean normal pelvic incidence was 45° (median 44°, SD 7°). The prevalence of spondylolysis was 1% in children under age 3 (n = 3 among 292 patients), 3.7% in children under age 6 (n = 17 among 454 patients) and 4.7% among the 532 patients. Unilateral spondylolysis was significantly associated with a spinal malformation (p = 0.04, Fisher's exact test), with normal pelvic incidence. Half of the patients with bilateral spondylolysis had high pelvic incidence. We observed a prevalence peak of unilateral spondylolysis in the context of a specific malformation in young infants under age 4 with normal pelvic incidence, and, then, a progressive increase in the prevalence of bilateral isolated spondylolysis.

  7. Serum uric acid to creatinine ratio: A predictor of incident chronic kidney disease in type 2 diabetes mellitus patients with preserved kidney function.

    PubMed

    Gu, Liubao; Huang, Liji; Wu, Haidi; Lou, Qinglin; Bian, Rongwen

    2017-05-01

    Serum uric acid has shown to be a predictor of renal disease progression in most but not all studies. This study aims to test whether renal function-normalized serum uric acid is superior to serum uric acid as the predictor of incident chronic kidney disease in type 2 diabetes mellitus patients. In this study, 1339 type 2 diabetes mellitus patients with estimated glomerular filtration rate ⩾60 mL/min/1.73 m 2 and normouricemia were included. Renal function-normalized serum uric acid was calculated using serum uric acid/creatinine. Cox regression analysis was used to estimate the association between serum uric acid, renal function-normalized serum uric acid and incident chronic kidney disease. In total, 74 (5.53%) patients developed to chronic kidney disease 3 or greater during a median follow-up of 4 years, with older ages, longer diabetes duration and lower estimated glomerular filtration rate at baseline. The decline rate of estimated glomerular filtration rate was positively correlated with serum uric acid/creatinine ( r = 0.219, p < 0.001), but not serum uric acid ( r = 0.005, p = 0.858). Moreover, multivariate analysis revealed that serum uric acid was not an independent risk factor for incident chronic kidney disease ( p = 0.055), whereas serum uric acid to creatinine ratio was significantly associated with incident chronic kidney disease independently of potential confounders including baseline estimated glomerular filtration rate. serum uric acid to creatinine ratio might be a better predictor of incident chronic kidney disease in type 2 diabetes mellitus patients.

  8. Thyroid hormone levels and incident chronic kidney disease in euthyroid individuals: the Kangbuk Samsung Health Study.

    PubMed

    Zhang, Yiyi; Chang, Yoosoo; Ryu, Seungho; Cho, Juhee; Lee, Won-Young; Rhee, Eun-Jung; Kwon, Min-Jung; Pastor-Barriuso, Roberto; Rampal, Sanjay; Han, Won Kon; Shin, Hocheol; Guallar, Eliseo

    2014-10-01

    Overt and subclinical hypothyroidism are associated with higher levels of serum creatinine and with increased risk of chronic kidney disease (CKD). The prospective association between thyroid hormones and kidney function in euthyroid individuals,however, is largely unexplored. We conducted a prospective cohort study in 104 633 South Korean men and women who were free of CKD and proteinuria at baseline and had normal thyroid hormone levels and no history of thyroid disease or cancer. At each annual or biennial follow-up visit, thyroid-stimulating hormone (TSH), free triiodothyronine (FT3) and free thyroxin (FT4) levels were measured by radioimmunoassay. The study outcome was incident CKD, defined as an estimated glomerular filtration rate (eGFR)<60 ml/min/1.73 m2 based on the Chronic Kidney Disease Epidemiology Collaboration creatinine equation. After a median follow-up of 3.5 years, 1032 participants developed incident CKD.There was a positive association between high-normal levels of TSH and increased risk of incident CKD. In fully-adjusted models including baseline eGFR, the hazard ratio comparing the highest vs the lowest quintiles of TSH was 1.26 [95% confidence interval (CI) 1.02 to 1.55; P for linear trend=0.03]. In spline models, FT3 levels below 3 pg/ml were also associated with increased risk of incident CKD. There was no association between FT4 levels and CKD. In a large cohort of euthyroid men and women, high levels of TSH and low levels of FT3, even within the normal range, were modestly associated with an increased risk of incident CKD.

  9. Trampoline motions in Xe-graphite(0 0 0 1) surface scattering

    NASA Astrophysics Data System (ADS)

    Watanabe, Yoshimasa; Yamaguchi, Hiroki; Hashinokuchi, Michihiro; Sawabe, Kyoichi; Maruyama, Shigeo; Matsumoto, Yoichiro; Shobatake, Kosuke

    2005-09-01

    We have investigated Xe scattering from the graphite(0 0 0 1) surface at hyperthermal incident energies using a molecular beam-surface scattering technique and molecular dynamics simulations. For all incident conditions, the incident Xe atom conserves the momentum parallel to the surface and loses approximately 80% of the normal incident energy. The weak interlayer potential of graphite disperses the deformation over the wide range of a graphene sheet. The dynamic corrugation induced by the collision is smooth even at hyperthermal incident energy; the graphene sheet moves like a trampoline net and the Xe atom like a trampoliner.

  10. Reflectance model of a plant leaf

    NASA Technical Reports Server (NTRS)

    Kumar, R.; Silva, L.

    1973-01-01

    A light ray, incident at 5 deg to the normal, is geometrically plotted through the drawing of the cross section of a soybean leaf using Fresnel's Equations and Snell's Law. The optical mediums of the leaf considered for ray tracing are: air, cell sap, chloroplast, and cell wall. The above ray is also drawn through the same leaf cross section considering cell wall and air as the only optical mediums. The values of the reflection and transmission found from ray tracing agree closely with the experimental results obtained using a Beckman DK-2A Spectroreflectometer. Similarly a light ray, incident at about 60 deg to the normal, is drawn through the palisade cells of a soybean leaf to illustrate the pathway of light, incident at an oblique angle, through the palisade cells.

  11. Chiral tunneling in a twisted graphene bilayer.

    PubMed

    He, Wen-Yu; Chu, Zhao-Dong; He, Lin

    2013-08-09

    The perfect transmission in a graphene monolayer and the perfect reflection in a Bernal graphene bilayer for electrons incident in the normal direction of a potential barrier are viewed as two incarnations of the Klein paradox. Here we show a new and unique incarnation of the Klein paradox. Owing to the different chiralities of the quasiparticles involved, the chiral fermions in a twisted graphene bilayer show an adjustable probability of chiral tunneling for normal incidence: they can be changed from perfect tunneling to partial or perfect reflection, or vice versa, by controlling either the height of the barrier or the incident energy. As well as addressing basic physics about how the chiral fermions with different chiralities tunnel through a barrier, our results provide a facile route to tune the electronic properties of the twisted graphene bilayer.

  12. Impact Damage Detection of Toughened CFRP Laminates with Time Domain Reflectometry

    DTIC Science & Technology

    2013-01-30

    detect damage of the CFRP structures. 3. Experiments Material used for the experiments is IM600/133 highly toughened CFRP prepreg produced by Toho...Tenux Co. Ltd. The long specimen shown in Fig. 5 is made from the prepreg . The cure condition is 180°C×0.7MPa×2h. The specimen’s stacking sequence

  13. 2-μm optical time domain reflectometry measurements from novel Al-, Ge-, CaAlSi- doped and standard single-mode fibers

    NASA Astrophysics Data System (ADS)

    Rodriguez-Novelo, J. C.; Sanchez-Nieves, J. A.; Sierra-Calderon, A.; Sanchez-Lara, R.; Alvarez-Chavez, J. A.

    2017-08-01

    The development of novel Al-, Ge- doped and un-doped standard single mode fibers for future optical communication at 2μm requires the integration of, among other pieces of equipment, an optical time domain reflectometry (OTDR) technique for precise spectral attenuation characterization, including the well-known cut-back method. The integration of a state of the art OTDR at 2μm could provide valuable attenuation information from the aforementioned novel fibers. The proposed setup consists of a 1.7 mW, 1960nm pump source, a 30 dB gain Thulium doped fibre amplifier at 2μm, an 0.8mm focal length lens with a 0.5 NA, a 30 MHz acusto-optic modulator, a 3.1 focal length lens with a 0.68NA, an optical circulator at 2μm, an InGaAs photodetector for 1.2 nm-2.6 nm range, a voltage amplifier and an oscilloscope. The propagated pulse rate is 50 KHz, with 500 ns, 200 ns, 100 ns and 50 ns pulse widths. Attenuation versus novel fibers types for lengths ranging from 400- to 1000- meter samples were obtained using the proposed setup.

  14. Comparison between measured and predicted turbulence frequency spectra in ITG and TEM regimes

    NASA Astrophysics Data System (ADS)

    Citrin, J.; Arnichand, H.; Bernardo, J.; Bourdelle, C.; Garbet, X.; Jenko, F.; Hacquin, S.; Pueschel, M. J.; Sabot, R.

    2017-06-01

    The observation of distinct peaks in tokamak core reflectometry measurements—named quasi-coherent-modes (QCMs)—are identified as a signature of trapped-electron-mode (TEM) turbulence (Arnichand et al 2016 Plasma Phys. Control. Fusion 58 014037). This phenomenon is investigated with detailed linear and nonlinear gyrokinetic simulations using the Gene code. A Tore-Supra density scan is studied, which traverses through a linear (LOC) to saturated (SOC) ohmic confinement transition. The LOC and SOC phases are both simulated separately. In the LOC phase, where QCMs are observed, TEMs are robustly predicted unstable in linear studies. In the later SOC phase, where QCMs are no longer observed, ion-temperature-gradient (ITG) modes are identified. In nonlinear simulations, in the ITG (SOC) phase, a broadband spectrum is seen. In the TEM (LOC) phase, a clear emergence of a peak at the TEM frequencies is seen. This is due to reduced nonlinear frequency broadening of the underlying linear modes in the TEM regime compared with the ITG regime. A synthetic diagnostic of the nonlinearly simulated frequency spectra reproduces the features observed in the reflectometry measurements. These results support the identification of core QCMs as an experimental marker for TEM turbulence.

  15. Characterization of edge turbulence in different states of divertor detachment using reflectometry in the ASDEX Upgrade tokamak

    NASA Astrophysics Data System (ADS)

    Nikolaeva, V.; Guimarais, L.; Manz, P.; Carralero, D.; Manso, M. E.; Stroth, U.; Silva, C.; Conway, G. D.; Seliunin, E.; Vicente, J.; Brida, D.; Aguiam, D.; Santos, J.; Silva, A.; ASDEX Upgrade team; MST1 team

    2018-05-01

    Transport in the scrape-off layer (SOL) depends on the state of divertor detachment. L-mode discharges were analyzed where the state of divertor detachment is varied through a density ramp-up. By means of reflectometry measurements at the low (LFS) and the high field side (HFS), midplane density fluctuations are studied for the first time in ASDEX Upgrade simultaneously at both sides of the tokamak. Radial density fluctuation profiles (δ {n}e/{n}e) increase with radius in both the HFS and the LFS. It is found that in the SOL density fluctuations at the LFS have about a factor of two larger amplitude than at the HFS in agreement with ballooned transport. Density fluctuations at the LFS show a modest variation with increasing background density resulting mainly from a rise of low frequency components. Experimental results are in good agreement with an enhanced convection of filaments at the LFS at the beginning of outer divertor detachment leading to a flatter SOL density profile. In this phase of the discharge, density fluctuations measured at the HFS far-SOL display a strong increase, which may be associated with the presence of faster filaments originated at the LFS.

  16. Time domain reflectometry measured moisture content of sewage sludge compost across temperatures.

    PubMed

    Cai, Lu; Chen, Tong-Bin; Gao, Ding; Liu, Hong-Tao; Chen, Jun; Zheng, Guo-Di

    2013-01-01

    Time domain reflectometry (TDR) is a prospective measurement technology for moisture content of sewage sludge composting material; however, a significant dependence upon temperature has been observed. The objective of this study was to assess the impacts of temperature upon moisture content measurement and determine if TDR could be used to monitor moisture content in sewage sludge compost across a range of temperatures. We also investigated the combined effects of temperature and conductivity on moisture content measurement. The results revealed that the moisture content of composting material could be determined by TDR using coated probes, even when the measured material had a moisture content of 0.581 cm(3)cm(-3), temperature of 70°C and conductivity of 4.32 mS cm(-1). TDR probes were calibrated as a function of dielectric properties that included temperature effects. When the bulk temperature varied from 20°C to 70°C, composting material with 0.10-0.70 cm(3)cm(-3) moisture content could be measured by TDR using coated probes, and calibrations based on different temperatures minimized the errors. Copyright © 2012. Published by Elsevier Ltd.

  17. Active Time-Domain Reflectometry for Unattended Safeguards Systems: FY16 Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tedeschi, Jonathan R.; Smith, Leon E.; Conrad, Ryan C.

    2016-10-21

    The International Atomic Energy Agency (IAEA) continues to expand its use of unattended measurement systems. An increasing number of systems and an expanding family of instruments create challenges in terms of deployment efficiency and the implementation of data authentication measures. Traditional data security measures, for example tamper-indicating (TI) conduit, are impractical for the long separation distances (often 100 meters or more) between unattended monitoring system (UMS) components. Pacific Northwest National Laboratory (PNNL) is studying the viability of active time-domain reflectometry (TDR) for the detection of cable tampering in unattended radiation detection systems. The instrument concept under investigation would allow formore » unmanned cable integrity measurements, remote surveillance reporting and locating of cable faults and/or tampers. This report describes PNNL’s FY16 progress and includes: an overview of the TDR methods under investigation; description of the TDR evaluation testbed developed by PNNL; development and testing of advanced signal processing algorithms to extract weak signals from relatively high noise levels; and initial testing of a laboratory prototype intended for IAEA UMS applications and based on a commercially available TDR module. Preliminary viability findings and recommendations for the next stage of development and testing are provided.« less

  18. Ultrasonic monitoring of droplets' evaporation: Application to human whole blood.

    PubMed

    Laux, D; Ferrandis, J Y; Brutin, D

    2016-09-01

    During a colloidal droplet evaporation, a sol-gel transition can be observed and is described by the desiccation time τD and the gelation time τG. These characteristic times, which can be linked to viscoelastic properties of the droplet and to its composition, are classically rated by analysis of mass droplet evolution during evaporation. Even if monitoring mass evolution versus time seems straightforward, this approach is very sensitive to environmental conditions (vibrations, air flow…) as mass has to be evaluated very accurately using ultra-sensitive weighing scales. In this study we investigated the potentialities of ultrasonic shear reflectometry to assess τD and τG in a simple and reliable manner. In order to validate this approach, our study has focused on blood droplets evaporation on which a great deal of work has recently been published. Desiccation and gelation times measured with shear ultrasonic reflectometry have been perfectly correlated to values obtained from mass versus time analysis. This ultrasonic method which is not very sensitive to environmental perturbations is therefore very interesting to monitor the drying of blood droplets in a simple manner and is more generally suitable for complex fluid droplets evaporation investigation. Copyright © 2016 Elsevier B.V. All rights reserved.

  19. AMOR - the versatile reflectometer at SINQ

    NASA Astrophysics Data System (ADS)

    Clemens, D.; Gross, P.; Keller, P.; Schlumpf, N.; Könnecke, M.

    2000-03-01

    We report on a new facility for neutron reflectometry situated at the end position of a cold neutron guide at the Swiss Spallation Neutron Source SINQ. The instrument is a flexible apparatus, adaptable to the needs of the user's individual experiment. Principally designed to operate in the time-of-flight mode it is also capable to exploit the fact that SINQ is a continuous source because PSI's developments in the field of thin film multilayers are fruitfully applied. By means of multilayer monochromators it can be converted into a constant wavelength reflectometer. Polarized neutron reflectometry on AMOR takes advantage of remanent FeCo/Ti:N supermirrors and multilayers which can be operated in a way that no spin flippers are needed. The time and angular contributions to the resolution in momentum transfer are separately determinable in TOF mode. The total length of the instrument is adjustable in order to optimize resolution together with the illumination of the sample's surface. Large sample environments can be placed on the sample table that is actively isolated against vibrations. Single detectors and an EMBL 3He area detector can be chosen, alternatively. The instrument concept as well as parameters of its components are presented.

  20. Application of spatial time domain reflectometry measurements in heterogeneous, rocky substrates

    NASA Astrophysics Data System (ADS)

    Gonzales, C.; Scheuermann, A.; Arnold, S.; Baumgartl, T.

    2016-10-01

    Measurement of soil moisture across depths using sensors is currently limited to point measurements or remote sensing technologies. Point measurements have limitations on spatial resolution, while the latter, although covering large areas may not represent real-time hydrologic processes, especially near the surface. The objective of the study was to determine the efficacy of elongated soil moisture probes—spatial time domain reflectometry (STDR)—and to describe transient soil moisture dynamics of unconsolidated mine waste rock materials. The probes were calibrated under controlled conditions in the glasshouse. Transient soil moisture content was measured using the gravimetric method and STDR. Volumetric soil moisture content derived from weighing was compared with values generated from a numerical model simulating the drying process. A calibration function was generated and applied to STDR field data sets. The use of elongated probes effectively assists in the real-time determination of the spatial distribution of soil moisture. It also allows hydrologic processes to be uncovered in the unsaturated zone, especially for water balance calculations that are commonly based on point measurements. The elongated soil moisture probes can potentially describe transient substrate processes and delineate heterogeneity in terms of the pore size distribution in a seasonally wet but otherwise arid environment.

  1. Observation of the electron density fluctuations by using the O-mode Microwave Imaging Reflectometry in LHD

    NASA Astrophysics Data System (ADS)

    Nagayama, Yoshio; Yamaguchi, Soichiro; Tsuchiya, Hayato; Kuwahara, Daisuke; LHD Experimental Team

    2016-10-01

    Visualization of local electron density fluctuations will be very useful to study the physics of confinement and instabilities in fusion plasma. In the Large Helical Device (LHD), the O-mode microwave imaging reflectometry (O-MIR) has been intensively developed in order to visualize the electron density fluctuations. The frequency is 26 - 34 GHz. This corresponds to the electron density of 0.8 - 1.5 × 1019 m-3. The plasma is illuminated by the Gaussian beam with four frequencies. The imaging optics make a plasma image onto the newly developed 2D (8 × 8) Horn-antenna Millimeter-wave Imaging Device (HMID). In HMID, the signal wave that is accumulated by the horn antenna is transduced to the micro-strip line by using the finline transducer. The signal wave is mixed by the double balanced mixer with the local wave that is delivered by cables. By using O-MIR, electron density fluctuations are measured at the H-mode edge and the ITB layer in LHD. This work is supported by NIFS/NINS under the project of Formation of International Scientific Base and Network, by the NIFS LHD project, by KAKENHI, and by IMS.

  2. Stability of self-assembled polymer films investigated by optical laser reflectometry.

    PubMed

    Dejeu, Jérôme; Diziain, Séverine; Dange, Catherine; Membrey, François; Charraut, Daniel; Foissy, Alain

    2008-04-01

    We studied the influence of post-treatment rinsing after the formation of self-assembled polyelectrolyte films made with the weak base poly(allylamine hydrochloride) (PAH) and the strong acid poly(styrene sulfonate) (PSS). The stability of the film was studied using optical fixed-angle laser reflectometry to measure the release of polymeric material and AFM experiments to reveal the change of morphology and thickness. We found that the polymer films were stable upon rinsing when the pH was the same in the solution as that used in the buildup (pH 9). The films released most of the polymeric material when rinsed at higher pH values, but a layer remained that corresponded to a PAH monolayer directly bound with the silica surface. Films containing at least four bilayers were stable upon rinsing at lower pH values, but the stability of thinner films depended on the type of the last polymer deposited. They were stable in the case of PSS as an outermost deposit, but they released a large part of their material in the case of PAH. The stability results were determined using a simple model of the step-by-step assembly of the polymer film described formerly.

  3. Testing of Piezo-Actuated Glass Micro-Membranes by Optical Low-Coherence Reflectometry.

    PubMed

    Merlo, Sabina; Poma, Paolo; Crisà, Eleonora; Faralli, Dino; Soldo, Marco

    2017-02-25

    In this work, we have applied optical low-coherence reflectometry (OLCR), implemented with infra-red light propagating in fiberoptic paths, to perform static and dynamic analyses on piezo-actuated glass micro-membranes. The actuator was fabricated by means of thin-film piezoelectric MEMS technology and was employed for modifying the micro-membrane curvature, in view of its application in micro-optic devices, such as variable focus micro-lenses. We are here showing that OLCR incorporating a near-infrared superluminescent light emitting diode as the read-out source is suitable for measuring various parameters such as the micro-membrane optical path-length, the membrane displacement as a function of the applied voltage (yielding the piezo-actuator hysteresis) as well as the resonance curve of the fundamental vibration mode. The use of an optical source with short coherence-time allows performing interferometric measurements without spurious resonance effects due to multiple parallel interfaces of highly planar slabs, furthermore selecting the plane/layer to be monitored. We demonstrate that the same compact and flexible setup can be successfully employed to perform spot optical measurements for static and dynamic characterization of piezo-MEMS in real time.

  4. Testing of Piezo-Actuated Glass Micro-Membranes by Optical Low-Coherence Reflectometry

    PubMed Central

    Merlo, Sabina; Poma, Paolo; Crisà, Eleonora; Faralli, Dino; Soldo, Marco

    2017-01-01

    In this work, we have applied optical low-coherence reflectometry (OLCR), implemented with infra-red light propagating in fiberoptic paths, to perform static and dynamic analyses on piezo-actuated glass micro-membranes. The actuator was fabricated by means of thin-film piezoelectric MEMS technology and was employed for modifying the micro-membrane curvature, in view of its application in micro-optic devices, such as variable focus micro-lenses. We are here showing that OLCR incorporating a near-infrared superluminescent light emitting diode as the read-out source is suitable for measuring various parameters such as the micro-membrane optical path-length, the membrane displacement as a function of the applied voltage (yielding the piezo-actuator hysteresis) as well as the resonance curve of the fundamental vibration mode. The use of an optical source with short coherence-time allows performing interferometric measurements without spurious resonance effects due to multiple parallel interfaces of highly planar slabs, furthermore selecting the plane/layer to be monitored. We demonstrate that the same compact and flexible setup can be successfully employed to perform spot optical measurements for static and dynamic characterization of piezo-MEMS in real time. PMID:28245603

  5. Comparison of central corneal thickness measurements with a rotating scheimpflug camera, a specular microscope, optical low-coherence reflectometry, and ultrasound pachymetry in keratoconic eyes.

    PubMed

    Cinar, Yasin; Cingu, Abdullah Kursat; Turkcu, Fatih Mehmet; Cinar, Tuba; Sahin, Alparslan; Yuksel, Harun; Ari, Seyhmus

    2015-03-01

    To compare central corneal thickness (CCT) measurements with a rotating Scheimpflug camera (RSC), noncontact specular microscopy (SM), optical low-coherence reflectometry (OLCR), and ultrasonic pachymetry (UP) in keratoconus (KC) patients. In this prospective study, four CCT measurements taken with an RSC, SM, OLCR, and UP were compared in 81 eyes of 44 consecutive KC patients. The KC patients were divided into four subgroups according to Amsler-Krumeich's KC classification. The RSC and UP measurements of the CCT were not statistically significant in all the groups. Comparison of the SM vs. the OLCR measurements yielded statistically significant differences in all the KC patients and in all KC stages. In all the KC patients, RSC and OLCR showed a high correlation coefficient factor (r = 0.87, p = 0.000). CCT measurements with RSC are comparable to those achieved with UP. Compared with the other devices, according to SM measurements, the central cornea is thicker in all keratoconic eyes and in all KC grades, and it is thinner according to OLCR. RSC, UP, SM, and OLCR should not be used interchangeably in keratoconic eyes.

  6. Field Measurements and Numerical Simulations of Temperature and Moisture in Highway Engineering Using a Frequency Domain Reflectometry Sensor.

    PubMed

    Yao, Yong-Sheng; Zheng, Jian-Long; Chen, Zeng-Shun; Zhang, Jun-Hui; Li, Yong

    2016-06-10

    This paper presents a systematic pioneering study on the use of agricultural-purpose frequency domain reflectometry (FDR) sensors to monitor temperature and moisture of a subgrade in highway extension and reconstruction engineering. The principle of agricultural-purpose FDR sensors and the process for embedding this kind of sensors for subgrade engineering purposes are introduced. Based on field measured weather data, a numerical analysis model for temperature and moisture content in the subgrade's soil is built. Comparisons of the temperature and moisture data obtained from numerical simulation and FDR-based measurements are conducted. The results show that: (1) the embedding method and process, data acquisition, and remote transmission presented are reasonable; (2) the temperature and moisture changes are coordinated with the atmospheric environment and they are also in close agreement with numerical calculations; (3) the change laws of both are consistent at positions where the subgrade is compacted uniformly. These results suggest that the data measured by the agricultural-purpose FDR sensors are reliable. The findings of this paper enable a new and effective real-time monitoring method for a subgrade's temperature and moisture changes, and thus broaden the application of agricultural-purpose FDR sensors.

  7. Children with sickle cell anemia with normal transcranial Doppler ultrasounds and without silent infarcts have a low incidence of new strokes.

    PubMed

    Jordan, Lori C; Roberts Williams, Dionna O; Rodeghier, Mark J; Covert Greene, Brittany V; Ponisio, Maria R; Casella, James F; McKinstry, Robert C; Noetzel, Michael J; Kirkham, Fenella J; Meier, Emily R; Fuh, Beng; McNaull, Melissa; Sarnaik, Sharada; Majumdar, Suvankar; McCavit, Timothy L; DeBaun, Michael R

    2018-06-01

    In a prospective cohort study, we tested the hypothesis that children with sickle cell anemia (SCA) with normal transcranial Doppler ultrasound (TCD) velocities and without silent cerebral infarcts (SCIs) would have a lower incidence rate of new neurological events (strokes, seizures or transient ischemic attacks) compared to children with normal TCD measurements and SCIs, not receiving regular blood transfusions. Nonrandomized participants from the silent cerebral infarct transfusion (SIT) Trial who had screening magnetic resonance imaging (MRI) of the brain and normal TCD measurements were included. Follow-up ended at the time of first neurological event (stroke, seizure or transient ischemic attack), start of regular blood transfusion, or loss to follow-up, whichever came first. The primary endpoint was a new neurological event. Of 421 participants included, 68 had suspected SCIs. Mean follow-up was 3.6 years. Incidence rates of new neurological events in nontransfused participants with normal TCD values with SCIs and without SCIs were 1.71 and 0.47 neurological events per 100 patient-years, respectively, P = .065. The absence of SCI(s) at baseline was associated with a decreased risk of a new neurological event (hazard ratio 0.231, 95% CI 0.062-0.858; P = .029). Local pediatric neurologists examined 67 of 68 participants with suspected SCIs and identified 2 with overt strokes classified as SCIs by local hematologists; subsequently one had a seizure and the other an ischemic stroke. Children with SCA, without SCIs, and normal TCD measurements have a significantly lower rate of new neurological events when compared to those with SCIs and normal TCD measurements. Pediatric neurology assessment may assist risk stratification. © 2018 Wiley Periodicals, Inc.

  8. Isolated elliptically polarized attosecond soft X-ray with high-brilliance using polarization gating of harmonics from relativistic plasmas at oblique incidence.

    PubMed

    Chen, Zi-Yu; Li, Xiao-Ya; Li, Bo-Yuan; Chen, Min; Liu, Feng

    2018-02-19

    The production of intense isolated attosecond pulse is a major goal in ultrafast research. Recent advances in high harmonic generation from relativistic plasma mirrors under oblique incidence interactions gave rise to photon-rich attosecond pulses with circular or elliptical polarization. However, to achieve an isolated elliptical attosecond pulse via polarization gating using currently available long driving pulses remains a challenge, because polarization gating of high harmonics from relativistic plasmas is assumed only possible at normal or near-normal incidence. Here we numerically demonstrate a scheme around this problem. We show that via control of plasma dynamics by managing laser polarization, it is possible to gate an intense single attosecond pulse with high ellipticity extending to the soft X-ray regime at oblique incidence. This approach thus paves the way towards a powerful tool enabling high-time-resolution probe of dynamics of chiral systems and magnetic materials with current laser technology.

  9. Advanced lightweight optics development for space applications

    NASA Astrophysics Data System (ADS)

    Bilbro, James W.

    1998-01-01

    A considerable amount of effort over the past year has been devoted to exploring ultra-lightweight optics for two specific NASA programs, the Next Generation Space Telescope (NGST), and the High Throughput X-ray Spectrometer (HTXS). Experimental investigations have been undertaken in a variety of materials including glass, composites, nickel, beryllium, Carbon fiber reinforced Silicon Carbide (CSiC), Reaction Bonded Silicon Carbide, Chemical Vapor Deposited Silicon Carbide, and Silicon. Overall results of these investigations will be summarized, and specific details will be provided concerning the in-house development of ultra-lightweight nickel replication for both grazing incidence and normal incidence optics. This will include x-ray test results of the grazing incidence optic and cryogenic test results of the normal incidence optic. The status of two 1.5 meter diameter demonstration mirrors for NGST will also be presented. These two demonstrations are aimed at establishing the capability to manufacture and test mirrors that have an areal density of 15 kilograms per square meter. Efforts in thin membrane mirrors and Fresnel lenses will also be briefly discussed.

  10. Retrospective chart review of obesity and episodic and chronic illness among rural Mexican-American adolescents accessing rural health clinic services.

    PubMed

    Champion, Jane Dimmitt; Pierce, Sherrie; Collins, Jennifer L

    2015-06-01

    Obesity impacts the physical and psychological health of children and adolescents, and is a risk factor for development of episodic and chronic illness. Rural Mexican-American adolescents are at risk for obesity and associated chronic illnesses.The study used a retrospective chart review of data collected routinely in a rural health clinic setting from 1 January 2005 to 31 December 2010 to assess incidence of overweight/obesity status and episodic or chronic illness among Mexican-American adolescents aged 12-18 years. Analyses included body mass index, age, gender, and episodic or chronic illness diagnoses. Two hundred twelve charts were audited; women (n = 114, 53.8%), men (n = 98 46.2%); normal (n = 105, 49.5%), overweight/obese (n = 107, 50.5%). There were more female normal (n = 61, 53.5%) vs. overweight/obese (n = 53, 46.5%). More male overweight/obese (n = 54, 55.1%) than normal weight (n = 44, 44.9%). Age at first documented overweight/obesity status occurred in early adolescence (median = 13 years, mode = 12 years). Chronic illness incidence was higher among men than women, and overweight/obese vs. normal weight adolescents and in sub-categorizations by weight and specific illness. Incidence of episodic illness was higher among women than men, with variation by weight and specific illness. Disproportionately high incidence of episodic or chronic illness and overweight/obesity identified among rural Mexican-American adolescents compels intervention modification to improve effectiveness. © 2014 Wiley Publishing Asia Pty Ltd.

  11. Solar Cell Angle of Incidence Corrections

    NASA Technical Reports Server (NTRS)

    Burger, Dale R.; Mueller, Robert L.

    1995-01-01

    The Mars Pathfinder mission has three different solar arrays each of which sees changes in incidence angle during normal operation. When solar array angle of incidence effects was researched little published data was found. The small amount of-published data created a need to obtain and evaluate such data. The donation of the needed data, which was taken in the fall of 1994, was a major factor in the preparation of this paper.

  12. The impact of glucose disorders on cognition and brain volumes in the elderly: the Sydney Memory and Ageing Study.

    PubMed

    Samaras, Katherine; Lutgers, Helen L; Kochan, Nicole A; Crawford, John D; Campbell, Lesley V; Wen, Wei; Slavin, Melissa J; Baune, Bernard T; Lipnicki, Darren M; Brodaty, Henry; Trollor, Julian N; Sachdev, Perminder S

    2014-04-01

    Type 2 diabetes predicts accelerated cognitive decline and brain atrophy. We hypothesized that impaired fasting glucose (IFG) and incident glucose disorders have detrimental effects on global cognition and brain volume. We further hypothesized that metabolic and inflammatory derangements accompanying hyperglycaemia contribute to change in brain structure and function. This was a longitudinal study of a community-dwelling elderly cohort with neuropsychological testing (n = 880) and brain volumes by magnetic resonance imaging (n = 312) measured at baseline and 2 years. Primary outcomes were global cognition and total brain volume. Secondary outcomes were cognitive domains (processing speed, memory, language, visuospatial and executive function) and brain volumes (hippocampal, parahippocampal, precuneus and frontal lobe). Participants were categorised as normal, impaired fasting glucose at both assessments (stable IFG), baseline diabetes or incident glucose disorders (incident diabetes or IFG at 2 years). Measures included inflammatory cytokines and oxidative metabolites. Covariates were age, sex, education, non-English speaking background, smoking, blood pressure, lipid-lowering or antihypertensive medications, mood score, apolipoprotein E genotype and baseline cognition or brain volume. Participants with incident glucose disorders had greater decline in global cognition and visuospatial function compared to normal, similar to that observed in baseline diabetes. Homocysteine was independently associated with the observed effect of diabetes on executive function. Apolipoprotein E genotype did not influence the observed effects of diabetes on cognition. Incident glucose disorders and diabetes were also associated with greater 2-year decline in total brain volume, compared to normal (40.0 ± 4.2 vs. 46.7 ± 5.7 mm(3) vs. 18.1 ± 6.2, respectively, p < 0.005). Stable IFG did not show greater decline in global cognition or brain volumes compared to normal. Incident glucose disorders, like diabetes, are associated with accelerated decline in global cognition and brain volumes in non-demented elderly, whereas stable IFG is not. Preventing deterioration in glucose metabolism in the elderly may help preserve brain structure and function.

  13. Coupled vibrations of rectangular buildings subjected to normally-incident random wind loads

    USGS Publications Warehouse

    Safak, E.; Foutch, D.A.

    1987-01-01

    A method for analyzing the three-directional coupled dynamic response of wind-excited buildings is presented. The method is based on a random vibration concept and is parallel to those currently used for analyzing alongwind response. Only the buildings with rectangular cross-section and normally-incident wind are considered. The alongwind pressures and their correlations are represented by the well-known expressions that are available in the literature. The acrosswind forces are assumed to be mainly due to vortex shedding. The torque acting on the building is taken as the sum of the torque due to random alongwind forces plus the torque due to asymmetric acrosswind forces. The study shows the following: (1) amplitude of acrosswind vibrations can be several times greater than that of alongwind vibrations; (2) torsional vibrations are significant if the building has large frontal width, and/or it is asymmetric, and/or its torsional natural frequency is low; (3) even a perfectly symmetric structure with normally incident wind can experience significant torsional vibrations due to the randomness of wind pressures. ?? 1987.

  14. Upgrades to the Polarized Neutron Reflectometer Asterix at LANSCE

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pynn, Roger

    2015-03-16

    We have upgraded the polarized neutron reflectometer, Asterix, at the Lujan Neutron Scattering Center at Los Alamos for the benefit of the research communities that study magnetic and complex-fluid films, both of which play important roles in support of the DOE’s energy mission. The upgrades to the instrument include: • A secondary spectrometer that was integrated with a Huber sample goniometer purchased with other funds just prior to the start of our project. The secondary spectrometer provides a flexible length for the scattered flight path, includes a mechanism to select among 3 alternative polarization analyzers as well as a supportmore » for new neutron detectors. Also included is an optic rail for reproducible positioning of components for Spin Echo Scattering Angle Measurement (SESAME). The entire secondary spectrometer is now non-magnetic, as required for neutron Larmor labeling. • A broad-band neutron polarizer for the incident neutron beam based on the V geometry. • A wide-angle neutron polarization analyzer • A 2d position-sensitive neutron detector • Electromagnetic coils (Wollaston prisms) for SESAME plus the associated power supplies, cooling, safety systems and integration into the data acquisition system. The upgrades allowed a nearly effortless transition between configurations required to serve the polarized neutron reflectometry community, users of the 11 T cryomagnet and users of SESAME.« less

  15. Association of vitamin D status with incidence of enterotoxigenic, enteropathogenic and enteroaggregative Escherichia coli diarrhoea in children of urban Bangladesh.

    PubMed

    Ahmed, A M S; Soares Magalhaes, R J; Long, K Z; Ahmed, T; Alam, Md A; Hossain, Md I; Islam, Md M; Mahfuz, M; Mondal, D; Haque, R; Mamun, A A

    2016-08-01

    To evaluate the association between vitamin D status and diarrhoeal episodes by enterotoxigenic (ETEC), enteropathogenic (EPEC) and enteroaggregative (EAEC) E. coli in underweight and normal-weight children aged 6-24 months in urban Bangladesh. Cohorts of 446 normal-weight and 466 underweight children were tested separately for ETEC, EPEC and EAEC from diarrhoeal stool samples collected during 5 months of follow-up while considering vitamin D status at enrolment as the exposure. Cox proportional hazards models with unordered failure events of the same type were used to determine diarrhoeal risk factors after adjusting for sociodemographic and concurrent micronutrient status. Vitamin D status was not independently associated with the risk of incidence of ETEC, EPEC and EAEC diarrhoea in underweight children, but moderate-to-severe retinol deficiency was associated with reduced risk for EPEC diarrhoea upon adjustment. Among normal-weight children, insufficient vitamin D status and moderate-to-severe retinol deficiency were independently associated with 44% and 38% reduced risk of incidence of EAEC diarrhoea, respectively. These children were at higher risk of ETEC diarrhoea with vitamin D deficiency status when adjusted for micronutrient status only. This study demonstrates for the first time that normal-weight children with insufficient vitamin D status have a reduced risk of EAEC diarrhoea than children with sufficient status. Moderate-to-severe deficiency of serum retinol is associated with reduced risk of EPEC and EAEC diarrhoea in underweight and normal-weight children. © 2016 John Wiley & Sons Ltd.

  16. Reversal and Rotation Errors by Normal and Retarded Readers

    ERIC Educational Resources Information Center

    Black, F. William

    1973-01-01

    Reports an investigation of the incidence of and relationships among word and letter reversals in writing and Bender-Gestalt rotation errors in matched samples of normal and retarded readers. No significant diffenences were found in the two groups. (TO)

  17. Gradient metasurface for four-direction anomalous reflection in terahertz

    NASA Astrophysics Data System (ADS)

    Wang, Jiao; Jiang, Yannan

    2018-06-01

    In this paper, a four-direction anomalous reflection metasurface is proposed. The basic cells comprise of squares and circles, which are designed at various sizes and arranged in a super cell at regular spacing. Then, properly combining super cells molds a square phase gradient metasurface (PGM). It is mounted on an optical thickness gold mirror, which inhibits all light transmission. Markedly different from previously reported metasurfaces, the square PGM is characterized by four-direction reflection beams. It takes into consideration the normal incidence and the oblique incidence. For the normal incidence, that the degrees of the four reflection angles are identical is due to the x, - x, y and - y directional discontinuous phase gradients, and lies on the symmetric structure in the xoy plane, which is then revealed by the surface current distribution. Incident angles varying from -20° to 20°, the reflection angles are demonstrated in the oblique incidence. Moreover, the PGM is polarization-independent. The performance is attributed to the symmetry of structure, which is verified by Radar cross section. Simulated results prove that our method offers a simple and effective strategy for metasurface design in terahertz. The proposed PGM can aid in focused beams, steering beams, and shaped beams.

  18. Morphology of an aluminum alloy eroded by a jet of angular particles impinging at normal incidence

    NASA Technical Reports Server (NTRS)

    Rao, P. V.; Young, S. G.; Buckley, D. H.

    1983-01-01

    The erosion of an aluminum alloy impinged by crushed glass particles at normal incidence was studied. The erosion patterns were analyzed by scanning electron microscopy, energy dispersive X-ray spectroscopy, and surface profilometer measurements. From the analysis of specimens tested at various driving gas pressures and time intervals, four distinct erosion regions were identified. A study of pit morphology and its relationship to cumulative erosion was made. Cutting wear is believed to be the predominant material removal mechanism; some evidence of deformation wear was found during the incubation period.

  19. Dystocia in Friesian cows and its effects on postpartum reproductive performance and milk production

    PubMed Central

    Shamiah, Sh. M.; El-Hamd, M. A. Abu; Shitta, A. A.; El-Din, M. A. Tag

    2010-01-01

    A total of 1,243 records for 585 dairy Friesian cows from 1997–2004 were used to study the factors affecting dystocia and its effects on reproductive performance and milk production. The overall incidence of dystocia was 6.9%. The percentage of dystocia decreased with increasing live body weight, age, and parity of cows (P < 0.05); however, it increased with increasing birth weight of calves (P < 0.05). The highest percentage of dystocia was detected in winter season, but the least percentage was in summer season (P < 0.05). The percentage of incidence of dystocia was significantly (P < 0.05) higher with winter feeding compared to summer ration (8.2% vs. 5.1%). The percentage of incidence of dystocia was significantly (P < 0.05) higher with twinning than single calving (15.5% vs. 6.5%), while not significantly affected by the sex of born calves. Incidence of dystocia had adverse effects on reproductive performance and milk yield. The service interval, service period, days open, and calving interval were significantly (P < 0.05) longer in cows afflicted with dystocia compared to normal cows. The conception rate was lower (P < 0.05), but the number of service per conception was higher (P < 0.05) in cows afflicted with dystocia compared to normal cows (60.5% vs. 73.0% and 3.4 vs. 2.7, respectively). Average daily milk yield was lower (P < 0.05) by 1 kg for cows with incidence of dystocia compared to normal cows. PMID:20835761

  20. Metabolic markers associated with insulin resistance predict type 2 diabetes in Koreans with normal blood pressure or prehypertension.

    PubMed

    Sung, Ki-Chul; Park, Hyun-Young; Kim, Min-Ju; Reaven, Gerald

    2016-03-22

    Questions remain as to the association between essential hypertension and increased incidence of type 2 diabetes (T2DM). The premise of this analysis is that insulin resistance/compensatory hyperinsulinemia is a major predictor of T2DM, and the greater the prevalence of insulin resistance within any population, normotensive or hypertensive, the more likely T2DM will develop. The hypothesis to be tested is that surrogate estimates of insulin resistance will predict incident T2DM to a significant degree in persons with normal blood pressure or prehypertension. Analysis of data from a population-based survey of 10, 038 inhabitants of rural and urban areas of Korea, ≥40 years-old, initiated in 2001, with measures of demographic and metabolic characteristics at baseline and 8-years later. Participants were classified as having normal blood pressure or prehypertension, and three simple manifestations of insulin resistance related to the pathophysiology of T2DM used to predict incident T2DM: (1) glycemia (plasma glucose concentration 2-hour after 75 g oral glucose challenge = 2-hour PG); (2) hyperinsulinemia (plasma insulin concentration 2-hour after 75 g oral glucose challenge = 2-hour PI); and (3) dyslipidemia (ratio of fasting plasma triglyceride/high/density lipoprotein cholesterol concentration = TG/HDL-C ratio). Fully adjusted hazard ratios (HR, 95 % CI) for incident T2DM were highest (P < 0.001) in the quartile of individuals with the highest 2-hour PG concentrations, ranging from 5.84 (3.37-10.1) in women with prehypertension to 12.2 (7.12-21.00) in men with normal blood pressure. T2DM also developed to a significantly greater degree in subjects within the highest quartile of TG/HDL-C ratios, with HRs varying from 2.91 (1.63-2.58) in women with prehypertension (P < 0.001) to 1.77 (1.12-2.81, P < 0.05) in men with prehypertension. The least predictive index of insulin resistance was the 2-hour PI concentration. Subjects with normal blood pressure in the highest quartile of 2-hour PI concentrations were significantly associated with incident T2DM, with HRs of 1.5 (1.02-2.20, P = 0.25) and 2.02 (1.35-3.02, P < 0.001), in men and women, respectively. Finally, incidence of T2DM in the highest quartile was somewhat greater in patients with prehypertension, irrespective of predictor. Metabolic variables associated with insulin resistance (glycemia, insulinemia, and dyslipidemia) predict the development of T2DM in patients with either normal blood pressure or prehypertension.

  1. Tunable angle absorption of hyperbolic metamaterials based on plasma photonic crystals

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jiao, Zheng; Ning, Renxia, E-mail: nrxxiner@hsu.edu.cn; Xu, Yuan

    2016-06-15

    We present the design of a multilayer structure of hyperbolic metamaterials based on plasma photonic crystals which composed of two kinds of traditional dielectric and plasma. The relative permittivity of hyperbolic metamaterials has been studied at certain frequency range. The absorption and reflection of the multilayer period structure at normal and oblique incident have been investigated by the transfer matrix method. We discussed that the absorption is affected by the thickness of material and the electron collision frequency γ of the plasma. The results show that an absorption band at the low frequency can be obtained at normal incident anglemore » and another absorption band at the high frequency can be found at a large incident angle. The results may be applied by logical gate, stealth, tunable angle absorber, and large angle filter.« less

  2. Metrology and Alignment of Light Weight Grazing Incidence X-Ray Mirrors

    NASA Technical Reports Server (NTRS)

    Zhang, William; Content, David; Petre, Robert; Saha, Timo

    2000-01-01

    Metrology and alignment of light weight X-ray optics have been a challenge for two reasons: (1) that the intrinsic mirror quality and distortions caused by handling can not be easily separated, and (2) the diffraction limits of the visible light become a severe problem at the order of one arc-minute. Traditional methods of using a normal incident pencil or small parallel beam which monitors a tiny fraction of the mirror in question at a given time can not adequately monitor those distortions. We are developing a normal incidence setup that monitors a large fraction, if not the whole, of the mirror at any given time. It will allow us to align thin X-ray mirrors to-an accuracy of a few arc seconds or to a limit dominated by the mirror intrinsic quality.

  3. Wavelength and bandwidth tunable photonic stopband of ferroelectric liquid crystals.

    PubMed

    Ozaki, Ryotaro; Moritake, Hiroshi

    2012-03-12

    The chiral smectic C phase of ferroelectric liquid crystals (FLCs) has a self-assembling helical structure which is regarded as a one-dimensional pseudo-photonic crystal. It is well known that a stopband of a FLC can be tuned in wavelength domain by changing temperature or electric field. We here have demonstrated an FLC stopband with independently tunable wavelength and bandwidth by controlling temperature and incident angle. At highly oblique incidence, the stopband does not have polarization dependence. Furthermore, the bandwidth at highly oblique incidence is much wider than that at normal incidence. The mechanism of the tunable stopband is clarified by considering the reflection at oblique incidence.

  4. Incidence angle normalization of radar backscatter data

    USDA-ARS?s Scientific Manuscript database

    NASA’s Soil Moisture Passive Active (SMAP) satellite (~2014) will include a radar system that will provide L-band multi-polarization backscatter at a constant incidence angle of 40º. During the pre-launch phase of the project there is a need for observations that will support the radar-based soil mo...

  5. Pressures force hospitals to declare major incidents.

    PubMed

    Evans, Nick

    2017-02-10

    More than 40% of hospitals in England were forced to declare major incidents during the first week of January, as bed shortages led to delays in emergency departments (EDs), thousands of trolley waits for beds and long queues of ambulances outside units. Even cancer operations, normally protected, were cancelled.

  6. Distributed sensor for water and pH measurements using fiber optics and swellable polymeric systems

    NASA Astrophysics Data System (ADS)

    Michie, W. C.; Culshaw, B.; McKenzie, I.; Konstantakis, M.; Graham, N. B.; Moran, C.; Santos, F.; Bergqvist, E.; Carlstrom, B.

    1995-01-01

    We report on the design, construction and test of a generic form of sensor for making distributed measurements of a range of chemical parameters. The technique combines optical time-domain reflectometry with chemically sensitive water-swellable polymers (hydrogels). Initial experiments have concentrated on demonstrating a distributed water detector; however, gels have been developed that enable this sensor to be

  7. Measurement of Sub Degree Angular Carbon Fiber Tow Misalignment

    NASA Technical Reports Server (NTRS)

    Wilson, William C.; Moore, Jason P.; McCraw, Hunter

    2017-01-01

    NASA is investigating the use of carbon fiber tow steering to tune aeroelastic characteristics in advanced composite structures. In support of that effort, NASA is also investigating methods of measuring the angle of carbon fiber tows as they are placed. This work presents the results of using microwave reflectometry in the approximately 2 GHz region to measure carbon fiber tow angles at 0.1deg resolution.

  8. 23RD International Conference on Phenomena in Ionized Gases, Volume 3

    DTIC Science & Technology

    1998-12-01

    discharges, and high pressure glows; arcs; high frequency discharges; ionospheric magnetospheric, and astrophysical plasmas; plasma diagnostic methods ...kf) in pulse reflectometry. Second, it different frequencies , and an Abel inversion is gives a quantitative model of the behaviour of the wave... design V method in the case of narrow mutual pitch of surface electrodes for high concentration ozone generation. 2. Experimental setup 20 The electrode

  9. Measuring the Moisture Content of Green Wood Using Time Domain Reflectometry

    Treesearch

    Laurence Schimleck; Kim Love-Myers; Joe Sanders; Heath Raybon; Richard Daniels; Jerry Mahon; Edward Andrews; Erik Schilling

    2011-01-01

    The responsible usage of water by facilities that rely on wet log storage in the southern United States has become an issue of great importance as restrictions on water usage have grown in recent years. In order to learn about the dynamics of moisture content in wet-stored logs over time, it is necessary to conduct continuous monitoring of log piles. Time domain...

  10. Ocean wind and roughness retrieval with spaceborne GNSS-Reflectometry: first results from the UK TechDemoSat-1 mission

    NASA Astrophysics Data System (ADS)

    Gommenginger, C.; Foti, G.

    2015-12-01

    GNSS-Reflectometry (GNSS-R) is a ground breaking ocean remote sensing technique that exploits reflected signals from Global Navigation Satellite Systems (GNSS) to retrieve geophysical information about the ocean surface such as near-surface winds above the ocean. Adopting a bistatic radar configuration, signals emitted by GNSS satellites flying in Medium Earth Orbit (MEO) are received by a GNSS-R receiver on a Low Earth Orbit (LEO) observatory utilizing both a zenith antenna to receive the direct signal from the GNSS and a nadir antenna to acquire the earth-reflected signal. The reflected signal originated from a glistening zone on the ocean surface sited around the Specular Point (SP), the geometrical point on the Earth surface where GNSS signals are forward scattered in the specular direction. The two signals are correlated for different shifts in time (delay) and frequency (Doppler) relative to the specular point (SP) to produce a so-called Delay Doppler Map (DDM) of forward-scattered electromagnetic power over the surface. This paper gives an overview of recent results obtained for wind speed and ocean roughness retrieval with the Low-Earth-Orbiting UK TechDemoSat-1 satellite (TDS-1). Launched in July 2014, TDS-1 provides the first new spaceborne Global Navigation Satellite System-Reflectometry (GNSS-R) data since the pioneering UK-Disaster Monitoring Mission experiment in 2003. We present examples of onboard-processed delay Doppler Maps, including excellent DDM data quality for winds up to 27.9 m/s. The relationship between observed GNSS-R signals, wind speed and ocean roughness is explored using global collocated matchup datasets with METOP ASCAT scatterometer winds and WaveWatch3 numerical wave model output. Several Geophysical Model Functions are proposed, that make it possible to retrieve wind speed without bias and with a precision of the order of 2 m/s even without calibration. This work demonstrates the capabilities of low-cost, low-mass, low-power GNSS-R receivers ahead of their launch on the NASA CYGNSS constellation in 2016.

  11. Ripple formation on Si surfaces during plasma etching in Cl2

    NASA Astrophysics Data System (ADS)

    Nakazaki, Nobuya; Matsumoto, Haruka; Sonobe, Soma; Hatsuse, Takumi; Tsuda, Hirotaka; Takao, Yoshinori; Eriguchi, Koji; Ono, Kouichi

    2018-05-01

    Nanoscale surface roughening and ripple formation in response to ion incidence angle has been investigated during inductively coupled plasma etching of Si in Cl2, using sheath control plates to achieve the off-normal ion incidence on blank substrate surfaces. The sheath control plate consisted of an array of inclined trenches, being set into place on the rf-biased electrode, where their widths and depths were chosen in such a way that the sheath edge was pushed out of the trenches. The distortion of potential distributions and the consequent deflection of ion trajectories above and in the trenches were then analyzed based on electrostatic particle-in-cell simulations of the plasma sheath, to evaluate the angular distributions of ion fluxes incident on substrates pasted on sidewalls and/or at the bottom of the trenches. Experiments showed well-defined periodic sawtooth-like ripples with their wave vector oriented parallel to the direction of ion incidence at intermediate off-normal angles, while relatively weak corrugations or ripplelike structures with the wave vector perpendicular to it at high off-normal angles. Possible mechanisms for the formation of surface ripples during plasma etching are discussed with the help of Monte Carlo simulations of plasma-surface interactions and feature profile evolution. The results indicate the possibility of providing an alternative to ion beam sputtering for self-organized formation of ordered surface nanostructures.

  12. Monte Carlo modeling of the scatter radiation doses in IR

    NASA Astrophysics Data System (ADS)

    Mah, Eugene; He, Wenjun; Huda, Walter; Yao, Hai; Selby, Bayne

    2011-03-01

    Purpose: To use Monte Carlo techniques to compute the scatter radiation dose distribution patterns around patients undergoing Interventional Radiological (IR) examinations. Method: MCNP was used to model the scatter radiation air kerma (AK) per unit kerma area product (KAP) distribution around a 24 cm diameter water cylinder irradiated with monoenergetic x-rays. Normalized scatter fractions (SF) were generated defined as the air kerma at a point of interest that has been normalized by the Kerma Area Product incident on the phantom (i.e., AK/KAP). Three regions surrounding the water cylinder were investigated consisting of the area below the water cylinder (i.e., backscatter), above the water cylinder (i.e., forward scatter) and to the sides of the water cylinder (i.e., side scatter). Results: Immediately above and below the water cylinder and in the side scatter region, values of normalized SF decreased with the inverse square of the distance. For z-planes further away, the decrease was exponential. Values of normalized SF around the phantom were generally less than 10-4. Changes in normalized SF with x-ray energy were less than 20% and generally decreased with increasing x-ray energy. At a given distance from region where the x-ray beam enters the phantom, the normalized SF was higher in the backscatter regions, and smaller in the forward scatter regions. The ratio of forward to back scatter normalized SF was lowest at 60 keV and highest at 120 keV. Conclusion: Computed SF values quantify the normalized fractional radiation intensities at the operator location relative to the radiation intensities incident on the patient, where the normalization refers to the beam area that is incident on the patient. SF values can be used to estimate the radiation dose received by personnel within the procedure room, and which depend on the imaging geometry, patient size and location within the room. Monte Carlo techniques have the potential for simulating normalized SF values for any arrangement of imaging geometry, patient size and personnel location and are therefore an important tool for minimizing operator doses in IR.

  13. Frequency of biochemical hypoglycaemia in adults with Type 1 diabetes with and without impaired awareness of hypoglycaemia: no identifiable differences using continuous glucose monitoring.

    PubMed

    Choudhary, P; Geddes, J; Freeman, J V; Emery, C J; Heller, S R; Frier, B M

    2010-06-01

    Impaired awareness of hypoglycaemia (IAH) is a major risk factor for severe hypoglycaemia in Type 1 diabetes. Although biochemical hypoglycaemia is asserted to be more frequent in IAH, this has not been estimated accurately. The aim of this study was to use Continuous Glucose Monitoring (CGM) to quantify hypoglycaemia in IAH and evaluate its use in identifying impaired awareness of hypoglycaemia. Ninety-five patients with Type 1 diabetes were classified as having normal (n = 74) or impaired awareness (n = 21) using an established method of assessing hypoglycaemia awareness. Hypoglycaemia exposure was assessed prospectively over 9-12 months using weekly 4-point capillary home blood glucose monitoring (HBGM), 5 days of CGM and prospective reporting of severe hypoglycaemia. The frequencies of biochemical and severe hypoglycaemia were compared in patients with normal and impaired awareness of hypoglycaemia. Patients with impaired awareness had a 3-fold higher incidence of severe hypoglycaemia than those with normal awareness [incidence rate ratio (IRR) 3.37 (95% CI 1.30-8.7); P = 0.01] and 1.6-fold higher incidence of hypoglycaemia on weekly HBGM [IRR 1.63 (95% CI 1.09-2.44); P = 0.02]. No significant differences were observed with CGM [IRR for sensor glucose < or = 3.0 mmol/l 1.47 (95% CI 0.91-2.39); P = 0.12; IRR for sensor glucose < or = 2.2 mmol/l 1.23 (95% CI 0.76-1.98); P = 0.40]. Patients with Type 1 diabetes with impaired awareness had a 3-fold higher risk of severe hypoglycaemia and 1.6-fold higher incidence of biochemical hypoglycaemia measured with weekly glucose monitoring compared with normal awareness, but 5 days of CGM did not differentiate those with impaired from those with normal awareness.

  14. Bladder cancer mapping in Libya based on standardized morbidity ratio and log-normal model

    NASA Astrophysics Data System (ADS)

    Alhdiri, Maryam Ahmed; Samat, Nor Azah; Mohamed, Zulkifley

    2017-05-01

    Disease mapping contains a set of statistical techniques that detail maps of rates based on estimated mortality, morbidity, and prevalence. A traditional approach to measure the relative risk of the disease is called Standardized Morbidity Ratio (SMR). It is the ratio of an observed and expected number of accounts in an area, which has the greatest uncertainty if the disease is rare or if geographical area is small. Therefore, Bayesian models or statistical smoothing based on Log-normal model are introduced which might solve SMR problem. This study estimates the relative risk for bladder cancer incidence in Libya from 2006 to 2007 based on the SMR and log-normal model, which were fitted to data using WinBUGS software. This study starts with a brief review of these models, starting with the SMR method and followed by the log-normal model, which is then applied to bladder cancer incidence in Libya. All results are compared using maps and tables. The study concludes that the log-normal model gives better relative risk estimates compared to the classical method. The log-normal model has can overcome the SMR problem when there is no observed bladder cancer in an area.

  15. Debris- and radiation-induced damage effects on EUV nanolithography source collector mirror optics performance

    NASA Astrophysics Data System (ADS)

    Allain, J. P.; Nieto, M.; Hendricks, M.; Harilal, S. S.; Hassanein, A.

    2007-05-01

    Exposure of collector mirrors facing the hot, dense pinch plasma in plasma-based EUV light sources to debris (fast ions, neutrals, off-band radiation, droplets) remains one of the highest critical issues of source component lifetime and commercial feasibility of nanolithography at 13.5-nm. Typical radiators used at 13.5-nm include Xe and Sn. Fast particles emerging from the pinch region of the lamp are known to induce serious damage to nearby collector mirrors. Candidate collector configurations include either multi-layer mirrors (MLM) or single-layer mirrors (SLM) used at grazing incidence. Studies at Argonne have focused on understanding the underlying mechanisms that hinder collector mirror performance at 13.5-nm under fast Sn or Xe exposure. This is possible by a new state-of-the-art in-situ EUV reflectometry system that measures real time relative EUV reflectivity (15-degree incidence and 13.5-nm) variation during fast particle exposure. Intense EUV light and off-band radiation is also known to contribute to mirror damage. For example offband radiation can couple to the mirror and induce heating affecting the mirror's surface properties. In addition, intense EUV light can partially photo-ionize background gas (e.g., Ar or He) used for mitigation in the source device. This can lead to local weakly ionized plasma creating a sheath and accelerating charged gas particles to the mirror surface and inducing sputtering. In this paper we study several aspects of debris and radiation-induced damage to candidate EUVL source collector optics materials. The first study concerns the use of IMD simulations to study the effect of surface roughness on EUV reflectivity. The second studies the effect of fast particles on MLM reflectivity at 13.5-nm. And lastly the third studies the effect of multiple energetic sources with thermal Sn on 13.5-nm reflectivity. These studies focus on conditions that simulate the EUVL source environment in a controlled way.

  16. Elemental depth profiling in transparent conducting oxide thin film by X-ray reflectivity and grazing incidence X-ray fluorescence combined analysis

    NASA Astrophysics Data System (ADS)

    Rotella, H.; Caby, B.; Ménesguen, Y.; Mazel, Y.; Valla, A.; Ingerle, D.; Detlefs, B.; Lépy, M.-C.; Novikova, A.; Rodriguez, G.; Streli, C.; Nolot, E.

    2017-09-01

    The optical and electrical properties of transparent conducting oxide (TCO) thin films are strongly linked with the structural and chemical properties such as elemental depth profile. In R&D environments, the development of non-destructive characterization techniques to probe the composition over the depth of deposited films is thus necessary. The combination of Grazing-Incidence X-ray Fluorescence (GIXRF) and X-ray reflectometry (XRR) is emerging as a fab-compatible solution for the measurement of thickness, density and elemental profile in complex stacks. Based on the same formalism, both techniques can be implemented on the same experimental set-up and the analysis can be combined in a single software in order to refine the sample model. While XRR is sensitive to the electronic density profile, GIXRF is sensitive to the atomic density (i. e. the elemental depth profile). The combination of both techniques allows to get simultaneous information about structural properties (thickness and roughness) as well as the chemical properties. In this study, we performed a XRR-GIXRF combined analysis on indium-free TCO thin films (Ga doped ZnO compound) in order to correlate the optical properties of the films with the elemental distribution of Ga dopant over the thickness. The variation of optical properties due to annealing process were probed by spectroscopic ellipsometry measurements. We studied the evolution of atomic profiles before and after annealing process. We show that the blue shift of the band gap in the optical absorption edge is linked to a homogenization of the atomic profiles of Ga and Zn over the layer after the annealing. This work demonstrates that the combination of the techniques gives insight into the material composition and makes the XRR-GIXRF combined analysis a promising technique for elemental depth profiling.

  17. [Impact of pre-pregnancy body mass index on baby's physical growth and nutritional status].

    PubMed

    Li, Hongyan; Tan, Shan; Gao, Xiao; Xiang, Shiting; Zhang, Li; Huang, Li; Xiong, Changhui; Yan, Qiang; Lin, Ling; Li, Dimin; Yi, Juan; Yan, Yan

    2015-04-01

    To explore the impact of pre-pregnancy body mass index on baby's physical growth and nutritional status. A total of 491 pairs of mother-infant were divided into 3 groups according to mother's pre-pregnancy body mass index (BMI): a pre-pregnancy low BMI group (BMI<18.5 kg/m², n=93), a pre-pregnancy normal BMI group (18.5 kg/m² ≤ BMI<24.0 kg/m², n=326), and a pre-pregnancy high BMI group (BMI ≥ 24.0 kg/m², n=72). Analysis of variance of repeated measurement data and the median percentage methods were used to compare the physical growth and nutritional status of babies in different groups. Baby's weight in the high BMI group were higher than that in the normal BMI and the low BMI group (F=3.958, P=0.020). The incidence of malnutrition in the low BMI group showed a tendency to decline along with the months (χ²=5.611, P=0.018), the incidence of overweight and obesity in the high and the normal BMI groups displayed a tendency to decline along with the months (χ²=18.773, 53.248, all P<0.001). Baby in the low BMI group had higher incidence of malnutrition while baby in the high BMI group had higher incidence of overweight and obesity. Pregnancy BMI was correlated with the growth of baby. Too high or too low prepregnancy BMI exerts harmful effect on baby's weight and nutritional status. Medical workers should strengthen the education on women's pre-pregnancy to remind them keeping BMI at normal level.

  18. Near- and far-field investigation of dark and bright higher order resonances in square loop elements at mid-infrared wavelengths.

    PubMed

    Tucker, Eric; D'Archangel, Jeffrey; Boreman, Glenn

    2017-03-06

    Three different size gold square loop structures were fabricated as arrays on ZnS over a ground plane and designed to have absorptive fundamental, second order, and third order resonances at a wavelength of 10.6 µm and 60° off-normal. The angular dependent far-field spectral absorptivity was investigated over the mid-infrared for each size loop array. It was found that the second order modes were dark at normal incidence, but became excited at off-normal incidence, which is consistent with previous work for similar geometry structures. Furthermore, near-field measurements and simulations at a wavelength of 10.6 µm and 60° off-normal showed that the second order mode (quadrupolar) of the medium size loop yielded a near-field response similar in magnitude to the fundamental mode (dipolar) of the small size loop, which can be important for sensing related applications where both strong near-field enhancement and more uniform or less localized field is beneficial.

  19. Association of green stem disorder with agronomic traits in soybean

    USDA-ARS?s Scientific Manuscript database

    Green stem disorder (GSD) of soybean is the occurrence of non-senescent, fleshy green stems of plants with normal, fully mature pods and seeds. The main focus of this study was to determine the relationship between GSD incidence and agronomic traits and to determine if GSD incidence was associated w...

  20. Perinatal Advantages and Disadvantages of Being Underweight before Pregnancy: A Population-Based Study.

    PubMed

    Trojner Bregar, Andreja; Blickstein, Isaac; Bržan Šimenc, Gabrijela; Janša, Vid; Verdenik, Ivan; Lučovnik, Miha; Tul, Nataša

    2017-01-01

    To evaluate the advantages and disadvantages of being underweight before pregnancy. Cohort study of a large population-based dataset of singleton births was used to compare maternal and neonatal outcomes of pre-gravid underweight body mass index (BMI <18.5 kg/m2) women with pre-gravid normal weight controls (BMI 18.5-24.9 kg/m2). A total of 10,995 pre-gravid underweight and 146,155 pre-gravid normal weight mothers were compared. The mean maternal age and gestational age were not different but lean mothers were significantly and more frequently primiparous, had a higher incidence of births at <36 and <32 weeks' gestation, and had a significantly higher incidence of low and very low birth weight infants. Lean mothers had a significantly lower incidence of birth weights >4,000 g, less cesarean births and a lower incidence of gestational diabetes and hypertensive disorders. A tradeoff exists between the advantages of being lean before pregnancy in terms of less maternal morbidity in return for gaining a more advanced gestational age and higher birth weight. © 2016 S. Karger AG, Basel.

  1. Tantalum films with well-controlled roughness grown by oblique incidence deposition

    NASA Astrophysics Data System (ADS)

    Rechendorff, K.; Hovgaard, M. B.; Chevallier, J.; Foss, M.; Besenbacher, F.

    2005-08-01

    We have investigated how tantalum films with well-controlled surface roughness can be grown by e-gun evaporation with oblique angle of incidence between the evaporation flux and the surface normal. Due to a more pronounced shadowing effect the root-mean-square roughness increases from about 2 to 33 nm as grazing incidence is approached. The exponent, characterizing the scaling of the root-mean-square roughness with length scale (α), varies from 0.75 to 0.93, and a clear correlation is found between the angle of incidence and root-mean-square roughness.

  2. The Incidence of Gastric Metaplasia in Patients with Duodenal Ulcer*

    PubMed Central

    Min, Young II; Lee, Byoung Wook; Chang, Young Woon; Chi, Hyun Sook; Lee, Jung Kook

    1987-01-01

    To investigate the incidence of duodenal gastric metaplasia and its underlying gastric or duodenal diseases, the authors obtained endoscopic biopsy specimens from the duodenal bulb at random sites during endoscopy from 19 normal subjects, 11 patients with gastric ulcer, 18 with duodenal and/or prepyloric ulcer (s), 7 with duodenitis and 8 with gastric erosions. The biopsy specimens were assessed with PAS staining to confirm gastric metaplasia. The incidence of duodenal gastric metaplasia was 72.2% in patients with duodenal and/or prepyloric ulcer (s), which contrasted with the patients with gastric ulcers (36.4%), duodenitis (42.9%), gastric erosions (12.5%), and normal subjects (5.3%). In conclusion, the results suggest that gastric metaplasia seen predominantly in patients with duodenal ulcer, seems to be related to hyperacidity and it plays some role in the pathogenesis of peptic ulcer in duodenum. PMID:3154823

  3. Age-related incidence of sclerotic glomeruli in human kidneys.

    PubMed Central

    Kaplan, C.; Pasternack, B.; Shah, H.; Gallo, G.

    1975-01-01

    The incidence of sclerotic glomeruli as a function of age in kidneys from 122 patients without clinical evidence of renal disease or hypertension was estimated by histologic quantitation. Based on statistical analysis of data from this sample, 95% of the normal population up to 40 years of age would be expected to have less than 10% sclerotic glomeruli. After the age of 40 years, the upper limit containing 95% of the normal population exceeds 10% sclerosis, and after the age of 50, there is a broad scatter of observed percentage of sclerotic glomeruli. These findings suggest that, in patients 40 years of age and younger, sclerosis of glomeruli at an incidence greater than 10% is disease-related, while in patients older than 40 years (and particularly those older than 50), there is a transition, and the distinction between abiotrophic involutional sclerosis and disease-related sclerosis becomes less clear. PMID:51591

  4. Prevalence of and antecedents to dementia-related missing incidents in the community.

    PubMed

    Bowen, Mary Elizabeth; McKenzie, Barbara; Steis, Melinda; Rowe, Meredeth

    2011-01-01

    The primary aim of this study is to examine the prevalence of and antecedents to missing incidents among community-dwelling persons with dementia. This prospective study used mailed surveys and telephone interviews. The prevalence of having any incident was 0.46/year; the overall prevalence for missing incidents in this study was 0.65/year. Missing incidents had few antecedents and occurred largely when persons with dementia were performing everyday activities that they normally completed without incident. Given that a missing incident is relatively common among persons with dementia, health care professionals should assist caregivers with a missing incident plan early in the disease process. Also, as missing persons are found by persons other than the caregiver and caregivers underutilize identification devices, health care professionals may recommend the use of identification devices to facilitate a safe return. Copyright © 2011 S. Karger AG, Basel.

  5. OPTICAL FIBRES AND FIBREOPTIC SENSORS: Polarisation reflectometry of anisotropic optical fibres

    NASA Astrophysics Data System (ADS)

    Konstantinov, Yurii A.; Kryukov, Igor'I.; Pervadchuk, Vladimir P.; Toroshin, Andrei Yu

    2009-11-01

    Anisotropic, polarisation-maintaining fibres have been studied using a reflectometer and integrated optic polariser. Linearly polarised pulses were launched into the fibre under test at different angles between their plane of polarisation and the main optical axis of the fibre. A special procedure for the correlation analysis of these reflectograms is developed to enhance the reliability of the information about the longitudinal optical uniformity ofanisotropic fibres.

  6. Self-Sensing TDR with Micro-Strip Line

    DTIC Science & Technology

    2015-06-11

    detect impact damage of a CFRP plate in the second year (Todoroki A, et al., Impact damage detection of a carbon- fibre -reinforced-polymer plate...inspection methods is self-sensing technology that uses carbon fibres as sensors [1]-[11]. The self-sensing technology applies electric current to the...Time Domain Reflectometry (TDR) for damage detection [15]-[17]. Authors have developed a self-sensing TDR for detection of fibre breakages using a

  7. Distributed electrical time domain reflectometry (ETDR) structural sensors: design models and proof-of-concept experiments

    NASA Astrophysics Data System (ADS)

    Stastny, Jeffrey A.; Rogers, Craig A.; Liang, Chen

    1993-07-01

    A parametric design model has been created to optimize the sensitivity of the sensing cable in a distributed sensing system. The system consists of electrical time domain reflectometry (ETDR) signal processing equipment and specially designed sensing cables. The ETDR equipment sends a high-frequency electric pulse (in the giga hertz range) along the sensing cable. Some portion of the electric pulse will be reflected back to the ETDR equipment as a result of the variation of the cable impedance. The electric impedance variation in the sensing cable can be related to its mechanical deformation, such as cable elongation (change in the resistance), shear deformation (change in the capacitance), corrosion of the cable or the materials around the cable (change in inductance and capacitance), etc. The time delay, amplitude, and shape of the reflected pulse provides the means to locate, determine the magnitude, and indicate the nature of the change in the electrical impedance, which is then related to the distributed structural deformation. The sensing cables are an essential part of the health-monitoring system. By using the parametric design model, the optimum cable parameters can be determined for specific deformation. Proof-of-concept experiments also are presented in the paper to demonstrate the utility of an electrical TDR system in distributed sensing applications.

  8. Interdigital Capacitance Local Non-Destructive Examination of Nuclear Power Plant Cable for Aging Management Programs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Glass, Samuel W.; Fifield, Leonard S.; Bowler, Nicola

    This Pacific Northwest National Laboratory milestone report describes progress to date on the investigation of non-destructive test methods focusing on local cable insulation and jacket testing using an interdigital capacitance (IDC) approach. Earlier studies have assessed a number of non-destructive examination (NDE) methods for bulk, distributed, and local cable tests. A typical test strategy is to perform bulk assessments of the cable response using dielectric spectroscopy, Tan , or partial discharge followed by distributed tests like time domain reflectometry or frequency domain reflectometry to identify the most likely defect location followed by a local test that can include visual inspection,more » indenter modulus tests, or Fourier Transform Infrared Spectroscopy (FTIR) or Near Infrared Spectroscopy FTIR (FTNIR). If a cable is covered with an overlaying jacket, the jacket’s condition is likely to be more severely degraded than the underlying insulation. None of the above local test approaches can be used to evaluate insulation beneath a cable jacket. Since the jacket’s function is neither structural nor electrical, a degraded jacket may not have any significance regarding the cable’s performance or suitability for service. IDC measurements offer a promising alternative or complement to these local test approaches including the possibility to test insulation beneath an overlaying jacket.« less

  9. Turbulence studies with means of reflectometry at TEXTOR

    NASA Astrophysics Data System (ADS)

    Krämer-Flecken, A.; Dreval, V.; Soldatov, S.; Rogister, A.; Vershkov, V.; TEXTOR-team

    2004-11-01

    At TEXTOR, an O-mode heterodyne reflectometer system is installed and operated for the measurement of plasma density fluctuations and turbulence investigations. With two antenna arrays in the equatorial and top positions having two and three horn antennae, respectively, poloidal correlations are investigated under different plasma scenarios. From the amplitude, cross-phase and coherency spectrum, differences in the ohmic and auxiliary heated discharges are investigated. Furthermore the dynamic behaviour of the turbulence is studied in the SOC-IOC transition and in the precursor phase of a disruption. For the latter an increased integrated power spectral density was observed at the X-point of the mode compared with the O-point. Stationary m = 2 mode activity is observed for the first time at TEXTOR by reflectometry. The fluctuation level is calculated for different conditions and rises significantly increasing heating power which is consistent with the L-mode confinement degradation. Correlation measurements yield the measured phase delays which are used to calculate the poloidal phase velocity perpendicular to the magnetic field. In ohmic plasmas the turbulence rotates like a 'rigid body' with constant angular velocity inside the q = 2 surface. The rigid body rotation is broken up during tangential neutral beam injection. From the deduced poloidal wavenumber of the turbulence, most likely ion temperature gradient modes are the driving mechanism of the turbulence.

  10. High-pressure cell for neutron reflectometry of supercritical and subcritical fluids at solid interfaces

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Carmichael, Justin R; Rother, Gernot; Browning, Jim

    2012-01-01

    A new high-pressure cell design for use in neutron reflectometry (NR) for pressures up to 50 MPa and a temperature range of 300 473 K is described. The cell design guides the neutron beam through the working crystal without passing through additional windows or the bulk fluid, which provides for a high neutron transmission, low scattering background, and low beam distortion. The o-ring seal is suitable for a wide range of subcritical and supercritical fluids and ensures high chemical and pressure stability. Wafers with a diameter of 5.08 cm (2 in.) and 5 mm or 10 mm thickness can bemore » used with the cells, depending on the required pressure and momentum transfer range. The fluid volume in the sample cell is very small at about 0.1 ml, which minimizes scattering background and stored energy. The cell design and pressure setup for measurements with supercritical fluids are described. NR data are shown for silicon/silicon oxide and quartz wafers measured against air and subsequently within the high-pressure cell to demonstrate the neutron characteristics of the high-pressure cell. Neutron reflectivity data for supercritical CO2 in contact with quartz and Si/SiO2 wafers are also shown.« less

  11. Active Time-Domain Reflectometry for Unattended Safeguards Systems FY15 Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tedeschi, Jonathan R.; Smith, Leon E.; Moore, David E.

    2015-09-01

    The International Atomic Energy Agency (IAEA) continues to expand its use of unattended measurement systems. An increasing number of systems and an expanding family of instruments create challenges in terms of deployment efficiency and the implementation of data authentication measures. In collaboration with the IAEA, tamper-indicating measures to address data-transmission authentication challenges with unattended safeguards systems are under investigation. Pacific Northwest National Laboratory (PNNL) is studying the viability of active time-domain reflectometry (TDR) along two parallel but interconnected paths: (1) swept-frequency TDR as the highly flexible, laboratory gold standard to which field-deployable options can be compared, and (2) a low-costmore » commercially available spread-spectrum TDR technology as one option for field implementation. This report describes PNNL’s FY15 progress in the viability study including: an overview of the TDR methods under investigation; description of the testing configurations and mock tampering scenarios; results from a preliminary sensitivity comparison of the two TDR methods; demonstration of a quantitative metric for estimating field performance that acknowledges the need for high detection probability while minimizing false alarms. FY15 progress reported here sets the stage for a rigorous comparison of the candidate TDR methods, over a range of deployment scenarios and perturbing effects typical of IAEA unattended monitoring systems.« less

  12. Field Measurements and Numerical Simulations of Temperature and Moisture in Highway Engineering Using a Frequency Domain Reflectometry Sensor

    PubMed Central

    Yao, Yong-Sheng; Zheng, Jian-Long; Chen, Zeng-Shun; Zhang, Jun-Hui; Li, Yong

    2016-01-01

    This paper presents a systematic pioneering study on the use of agricultural-purpose frequency domain reflectometry (FDR) sensors to monitor temperature and moisture of a subgrade in highway extension and reconstruction engineering. The principle of agricultural-purpose FDR sensors and the process for embedding this kind of sensors for subgrade engineering purposes are introduced. Based on field measured weather data, a numerical analysis model for temperature and moisture content in the subgrade’s soil is built. Comparisons of the temperature and moisture data obtained from numerical simulation and FDR-based measurements are conducted. The results show that: (1) the embedding method and process, data acquisition, and remote transmission presented are reasonable; (2) the temperature and moisture changes are coordinated with the atmospheric environment and they are also in close agreement with numerical calculations; (3) the change laws of both are consistent at positions where the subgrade is compacted uniformly. These results suggest that the data measured by the agricultural-purpose FDR sensors are reliable. The findings of this paper enable a new and effective real-time monitoring method for a subgrade’s temperature and moisture changes, and thus broaden the application of agricultural-purpose FDR sensors. PMID:27294935

  13. Measurement of water pressure and deformation with time domain reflectometry cables

    NASA Astrophysics Data System (ADS)

    Dowding, Charles H.; Pierce, Charles E.

    1995-05-01

    Time domain reflectometry (TDR) techniques can be deployed to measure water pressures and relative dam abutment displacement with an array of coaxial cables either drilled and grouted or retrofitted through existing passages. Application of TDR to dam monitoring requires determination of appropriate cable types and methods to install these cables in existing dams or during new construction. This paper briefly discusses currently applied and developing TDR techniques and describes initial design considerations for TDR-based dam instrumentation. Water pressure at the base of or within the dam can be determined by measuring the water level within a hollow or air-filled coaxial cable. The ability to retrofit existing porous stone-tipped piezometers is an attractive attribute of the TDR system. Measurement of relative lateral movement can be accomplished by monitoring local shearing of a solid polyethylene-filled coaxial cable at the interface of the dam base and foundation materials or along adversely oriented joints. Uplift can be recorded by measuring cable extension as the dam displaces upward off its foundation. Since each monitoring technique requires measurements with different types of coaxial cables, a variety may be installed within the array. Multiplexing of these cables will allow monitoring from a single pulser, and measurements can be recorded on site or remotely via a modem at any time.

  14. Effects of bulk colloidal stability on adsorption layers of poly(diallyldimethylammonium chloride)/sodium dodecyl sulfate at the air-water interface studied by neutron reflectometry.

    PubMed

    Campbell, Richard A; Yanez Arteta, Marianna; Angus-Smyth, Anna; Nylander, Tommy; Varga, Imre

    2011-12-29

    We show for the oppositely charged system poly(diallyldimethylammonium chloride)/sodium dodecyl sulfate that the cliff edge peak in its surface tension isotherm results from the comprehensive precipitation of bulk complexes into sediment, leaving a supernatant that is virtually transparent and a depleted adsorption layer at the air/water interface. The aggregation and settling processes take about 3 days to reach completion and occur at bulk compositions around charge neutrality of the complexes which lack long-term colloidal stability. We demonstrate excellent quantitative agreement between the measured surface tension values and a peak calculated from the surface excess of surfactant in the precipitation region measured by neutron reflectometry, using the approximation that there is no polymer left in the liquid phase. The nonequilibrium nature of the system is emphasized by the production of very different interfacial properties from equivalent aged samples that are handled differently. We go on to outline our perspective on the "true equilibrium" state of this intriguing system and conclude with a comment on its practical relevance given that the interfacial properties can be so readily influenced by the handling of kinetically trapped bulk aggregates. © 2011 American Chemical Society

  15. Distributed measurement of acoustic vibration location with frequency multiplexed phase-OTDR

    NASA Astrophysics Data System (ADS)

    Iida, Daisuke; Toge, Kunihiro; Manabe, Tetsuya

    2017-07-01

    All-fiber distributed vibration sensing is attracting attention in relation to structural health monitoring because it is cost effective, offers high coverage of the monitored area and can detect various structural problems. And in particular the demand for high-speed vibration sensing operating at more than 10 kHz has increased because high frequency vibration indicates high energy and severe trouble in the monitored object. Optical fiber vibration sensing with phase-sensitive optical time domain reflectometry (phase-OTDR) has long been studied because it can be used for distributed vibration sensing in optical fiber. However, pulse reflectometry such as OTDR cannot measure high-frequency vibration whose cycle is shorter than the repetition time of the OTDR. That is, the maximum detectable frequency depends on fiber length. In this paper, we describe a vibration sensing technique with frequency-multiplexed OTDR that can detect the entire distribution of a high-frequency vibration thus allowing us to locate a high-speed vibration point. We can measure the position, frequency and dynamic change of a high-frequency vibration whose cycle is shorter than the repetition time. Both frequency and position are visualized simultaneously for a 5-km fiber with an 80-kHz frequency response and a 20-m spatial resolution.

  16. SNR and Standard Deviation of cGNSS-R and iGNSS-R Scatterometric Measurements.

    PubMed

    Alonso-Arroyo, Alberto; Querol, Jorge; Lopez-Martinez, Carlos; Zavorotny, Valery U; Park, Hyuk; Pascual, Daniel; Onrubia, Raul; Camps, Adriano

    2017-01-19

    This work addresses the accuracy of the Global Navigation Satellite Systems (GNSS)-Reflectometry (GNSS-R) scatterometric measurements considering the presence of both coherent and incoherent scattered components, for both conventional GNSS-R (cGNSS-R) and interferometric GNSS-R (iGNSS-R) techniques. The coherent component is present for some type of surfaces, and it has been neglected until now because it vanishes for the sea surface scattering case. Taking into account the presence of both scattering components, the estimated Signal-to-Noise Ratio (SNR) for both techniques is computed based on the detectability criterion, as it is done in conventional GNSS applications. The non-coherent averaging operation is considered from a general point of view, taking into account that thermal noise contributions can be reduced by an extra factor of 0.88 dB when using partially overlapped or partially correlated samples. After the SNRs are derived, the received waveform's peak variability is computed, which determines the system's capability to measure geophysical parameters. This theoretical derivations are applied to the United Kingdom (UK) TechDemoSat-1 (UK TDS-1) and to the future GNSS REflectometry, Radio Occultation and Scatterometry on board the International Space Station (ISS) (GEROS-ISS) scenarios, in order to estimate the expected scatterometric performance of both missions.

  17. A PC based time domain reflectometer for space station cable fault isolation

    NASA Technical Reports Server (NTRS)

    Pham, Michael; McClean, Marty; Hossain, Sabbir; Vo, Peter; Kouns, Ken

    1994-01-01

    Significant problems are faced by astronauts on orbit in the Space Station when trying to locate electrical faults in multi-segment avionics and communication cables. These problems necessitate the development of an automated portable device that will detect and locate cable faults using the pulse-echo technique known as Time Domain Reflectometry. A breadboard time domain reflectometer (TDR) circuit board was designed and developed at the NASA-JSC. The TDR board works in conjunction with a GRiD lap-top computer to automate the fault detection and isolation process. A software program was written to automatically display the nature and location of any possible faults. The breadboard system can isolate open circuit and short circuit faults within two feet in a typical space station cable configuration. Follow-on efforts planned for 1994 will produce a compact, portable prototype Space Station TDR capable of automated switching in multi-conductor cables for high fidelity evaluation. This device has many possible commercial applications, including commercial and military aircraft avionics, cable TV, telephone, communication, information and computer network systems. This paper describes the principle of time domain reflectometry and the methodology for on-orbit avionics utility distribution system repair, utilizing the newly developed device called the Space Station Time Domain Reflectometer (SSTDR).

  18. Dielectric relaxation studies of binary mixture of β-picoline and methanol using time domain reflectometry at different temperatures

    NASA Astrophysics Data System (ADS)

    Trivedi, C. M.; Rana, V. A.; Hudge, P. G.; Kumbharkhane, A. C.

    2016-08-01

    Complex permittivity spectra of binary mixtures of varying concentrations of β-picoline and Methanol (MeOH) have been obtained using time domain reflectometry (TDR) technique over frequency range 10 MHz to 25 GHz at 283.15, 288.15, 293.15 and 298.15 K temperatures. The dielectric relaxation parameters namely static permittivity (ɛ0), high frequency limit permittivity (ɛ∞1) and the relaxation time (τ) were determined by fitting complex permittivity data to the single Debye/Cole-Davidson model. Complex nonlinear least square (CNLS) fitting procedure was carried out using LEVMW software. The excess permittivity (ɛ0E) and the excess inverse relaxation time (1/τ)E which contain information regarding molecular structure and interaction between polar-polar liquids were also determined. From the experimental data, parameters such as effective Kirkwood correlation factor (geff), Bruggeman factor (fB) and some thermo dynamical parameters have been calculated. Excess parameters were fitted to the Redlich-Kister polynomial equation. The values of static permittivity and relaxation time increase nonlinearly with increase in the mol-fraction of MeOH at all temperatures. The values of excess static permittivity (ɛ0E) and the excess inverse relaxation time (1/τ)E are negative for the studied β-picoline — MeOH system at all temperatures.

  19. Theory and tests of a thermal ion detector sensitive only at Near-normal incidence

    NASA Technical Reports Server (NTRS)

    Robinson, J. W.

    1981-01-01

    Measurements of thermal ions are influenced by factors such as spacecraft potential, velocity, angle of attack, and sheath size. A theory is presented for the response of an instrument which accepts ions only within a small angle of incidence from normal. Although a more general theory is available and forms the basis of this one, the small angle restriction allows a simpler formulation which does not depend on sheath size. Furthermore, practical instruments are easily designed around this restriction. Laboratory tests verify that such instruments respond as expected and they illustrate how design details influence perturbations from the ideal response characteristics.

  20. An anisotropic lens for transitioning plane waves between media of different permittivities

    NASA Astrophysics Data System (ADS)

    Stone, Alexander P.; Baum, Carl E.

    1988-11-01

    A particularly simple geometry is considered in which an inhomogeneous and anisotropic lens is specified for the transition of plane waves between media of different permittivities. The permittivities of the regions outside of the lens can be constant, but the permittivity of the lens region depends on position. Results are presented for a plane wave in the second medium propagating normally to the assumed plane boundary of that medium. The results for the case of normal incidence are then generalized to the case of nonnormal incidence. The conditions of transit time conservation and impedance matching are related to the Brewster angle.

  1. Normal Incidence for Graded Index Surfaces

    NASA Technical Reports Server (NTRS)

    Khankhoje, Uday K.; Van Zyl, Jakob

    2011-01-01

    A plane wave is incident normally from vacuum (eta(sub 0) = 1) onto a smooth surface. The substrate has three layers; the top most layer has thickness d(sub 1) and permittivity epsilon(sub 1). The corresponding numbers for the next layer are d(sub 2); epsilon(sub 2), while the third layer which is semi-in nite has index eta(sub 3). The Hallikainen model [1] is used to relate volumetric soil moisture to the permittivity. Here, we consider the relation for the real part of the permittivity for a typical loam soil: acute epsilon(mv) = 2.8571 + 3.9678 x mv + 118:85 x mv(sup 2).

  2. Analysis of normalized radar cross section (sigma-O) signature of Amazon rain forest using SEASAT scatterometer data

    NASA Technical Reports Server (NTRS)

    Bracalente, E. M.; Sweet, J. L.

    1984-01-01

    The normalized radar cross section (NRCS) signature of the Amazon rain forest was SEASAT scatterometer data. Statistics of the measured (NRCS) values were determined from multiple orbit passes for three local time periods. Plots of mean normalized radar cross section, dB against incidence angle as a function of beam and polarization show that less than 0.3 dB relative bias exists between all beams over a range of incidence angle from 30 deg to 53 deg. The backscattered measurements analyzed show the Amazon rain forest to be relatively homogeneous, azimuthally isotropic and insensitive to polarization. The return from the rain forest target appears relatively consistent and stable, except for the small diurnal variation (0.75 dB) that occurs at sunrise. Because of the relative stability of the rain forest target and the scatterometer instrument, the response of versus incidence angle was able to detect errors in the estimated yaw altitude angle. Also, small instrument gain biases in some of the processing channels were detected. This led to the development of an improved NRCS algorithm, which uses a more accurate method for estimating the system noise power.

  3. Light scattering of semitransparent sintered polytetrafluoroethylene films.

    PubMed

    Li, Qinghe; Lee, Bong Jae; Zhang, Zhuomin M; Allen, David W

    2008-01-01

    Polytetrafluoroethylene (PTFE) is a strongly scattering material and has been regarded to have optical properties similar to biological tissues. In the present study, the bidirectional reflectance distribution function (BRDF) and the bidirectional transmittance distribution function (BTDF) of several PTFE films, with thicknesses from 0.11 to 10 mm, are measured using a laser scatterometer at the wavelength of 635 nm. The directional-hemispherical reflectance (R) and transmittance (T) were obtained by integrating BRDF and BTDF for normal incidence. Comparison of the ratio of the measured R and T with that calculated from the adding-doubling method allows the determination of the reduced scattering coefficient. Furthermore, the effect of surface scattering is investigated by measuring the polarization-dependent BRDF and BTDF at oblique incidence. By analyzing the measurement uncertainty of BTDF in the near-normal observation angles at normal incidence, the present authors found that the scattering coefficient of PTFE should exceed 1200 cm(-1), which is much greater than that of biological tissues. On the other hand, the absorption coefficient of PTFE must be less than 0.01 cm(-1), much smaller than that of biological tissues, a necessary condition to achieve R > or =0.98 with a 10-mm-thick slab.

  4. Independent and combined effects of physical activity and body mass index on the development of Type 2 Diabetes - a meta-analysis of 9 prospective cohort studies.

    PubMed

    Cloostermans, Laura; Wendel-Vos, Wanda; Doornbos, Gerda; Howard, Bethany; Craig, Cora Lynn; Kivimäki, Mika; Tabak, Adam G; Jefferis, Barbara J; Ronkainen, Kimmo; Brown, Wendy J; Picavet, Susan H S J; Ben-Shlomo, Yoav; Laukkanen, Jari Antero; Kauhanen, Jussi; Bemelmans, Wanda J E

    2015-12-01

    The aim of this harmonized meta-analysis was to examine the independent and combined effects of physical activity and BMI on the incidence of type 2 diabetes. Our systematic literature review in 2011 identified 127 potentially relevant prospective studies of which 9 fulfilled the inclusion criteria (total N = 117,878, 56.2 % female, mean age = 50.0 years, range = 25-65 years). Measures of baseline physical activity (low, intermediate, high), BMI-category [BMI < 18.4 (underweight), 18.5-24.9 (normal weight), 25.0-29.9 (overweight), 30+ (obese)] and incident type 2 diabetes were harmonized across studies. The associations between physical activity, BMI and incident type 2 diabetes were analyzed using Cox regression with a standardized analysis protocol including adjustments for age, gender, educational level, and smoking. Hazard ratios from individual studies were combined in a random-effects meta-analysis. Mean follow-up time was 9.1 years. A total of 11,237 incident type 2 diabetes cases were recorded. In mutually adjusted models, being overweight or obese (compared with normal weight) and having low physical activity (compared with high physical activity) were associated with an increased risk of incident type 2 diabetes (hazard ratios 2.33, 95 % CI 1.95-2.78; 6.10, 95 % CI: 4.63-8.04, and 1.23, 95 % CI: 1.09-1.39, respectively). Individuals who were both obese and had low physical activity had 7.4-fold (95 % CI 3.47-15.89) increased risk of type 2 diabetes compared with normal weight, high physically active participants. This harmonized meta-analysis shows the importance of maintaining a healthy weight and being physically active in diabetes prevention.

  5. A comparative study on omnidirectional anti-reflection SiO2 nanostructure films coating by glancing angle deposition

    NASA Astrophysics Data System (ADS)

    Prachachet, R.; Samransuksamer, B.; Horprathum, M.; Eiamchai, P.; Limwichean, S.; Chananonnawathorn, C.; Lertvanithphol, T.; Muthitamongkol, P.; Boonruang, S.; Buranasiri, P.

    2018-02-01

    Fabricated omnidirectional anti-reflection nanostructure films as a one of the promising alternative solar cell applications have attracted enormous scientific and industrial research benefits to their broadband, effective over a wide range of incident angles, lithography-free and high-throughput process. Recently, the nanostructure SiO2 film was the most inclusive study on anti-reflection with omnidirectional and broadband characteristics. In this work, the three-dimensional silicon dioxide (SiO2) nanostructured thin film with different morphologies including vertical align, slant, spiral and thin films were fabricated by electron beam evaporation with glancing angle deposition (GLAD) on the glass slide and silicon wafer substrate. The morphological of the prepared samples were characterized by field-emission scanning electron microscope (FE-SEM) and high-resolution transmission electron microscope (HRTEM). The transmission, omnidirectional and birefringence property of the nanostructure SiO2 films were investigated by UV-Vis-NIR spectrophotometer and variable angle spectroscopic ellipsometer (VASE). The spectrophotometer measurement was performed at normal incident angle and a full spectral range of 200 - 2000 nm. The angle dependent transmission measurements were investigated by rotating the specimen, with incidence angle defined relative to the surface normal of the prepared samples. This study demonstrates that the obtained SiO2 nanostructure film coated on glass slide substrate exhibits a higher transmission was 93% at normal incident angle. In addition, transmission measurement in visible wavelength and wide incident angles -80 to 80 were increased in comparison with the SiO2 thin film and glass slide substrate due to the transition in the refractive index profile from air to the nanostructure layer that improve the antireflection characteristics. The results clearly showed the enhanced omnidirectional and broadband characteristic of the three dimensional SiO2 nanostructure film coating.

  6. Premorbid Body-Mass Index and Mortality after Incident Heart Failure: The Atherosclerosis Risk in Communities Study

    PubMed Central

    Khalid, Umair; Ather, Sameer; Bavishi, Chirag; Chan, Wenyaw; Loehr, Laura R.; Wruck, Lisa M.; Rosamond, Wayne D.; Chang, Patricia P.; Coresh, Joe; Virani, Salim S.; Nambi, Vijay; Bozkurt, Biykem; Ballantyne, Christie M.; Deswal, Anita

    2014-01-01

    BACKGROUND Although obesity is an independent risk factor for heart failure (HF), once HF is established, obesity is associated with lower mortality. It is unclear if the weight loss due to advanced HF leads to this paradoxical finding. OBJECTIVES We sought to evaluate the prognostic impact of pre-morbid obesity in patients with HF. METHODS In the Atherosclerosis Risk in Communities (ARIC) study, we used body mass index (BMI) measured ≥6 months before incident HF (pre-morbid BMI) to evaluate the association of overweight (BMI 25 to <30 kg/m2) and obesity (≥30 kg/m2) compared to normal BMI (18.5 to <25 kg/m2) with mortality after incident HF. RESULTS Among 1,487 patients with incident HF, 35% were overweight and 47% were obese by pre-morbid BMI measured 4.3 ± 3.1 years before HF diagnosis. Over 10-year follow-up after incident HF, 43% of patients died. After adjustment for demographics and comorbidities, being premorbidly overweight (hazard ratio [HR]: 0.72; 95% confidence interval [CI[]: 0.58 to 0.90; p = 0.004) or obese (HR: 0.70; 95% CI: 0.56 to 0.87; p = 0.001) had a protective association with survival compared to normal BMI. The protective effect of overweight and obesity was consistent across subgroups based on a history of cancer, smoking, and diabetes. CONCLUSIONS Our results, for the first time, demonstrate that individuals who were overweight or obese before HF development have lower mortality once they have HF compared with normal BMI individuals. Thus, weight loss due to advanced HF may not completely explain the protective effect of higher BMI in HF patients. PMID:25541126

  7. Coffee Consumption Habits and the Risk of Mild Cognitive Impairment: The Italian Longitudinal Study on Aging.

    PubMed

    Solfrizzi, Vincenzo; Panza, Francesco; Imbimbo, Bruno P; D'Introno, Alessia; Galluzzo, Lucia; Gandin, Claudia; Misciagna, Giovanni; Guerra, Vito; Osella, Alberto; Baldereschi, Marzia; Di Carlo, Antonio; Inzitari, Domenico; Seripa, Davide; Pilotto, Alberto; Sabbá, Carlo; Logroscino, Giancarlo; Scafato, Emanuele

    2015-01-01

    Coffee, tea, or caffeine consumption may be protective against cognitive impairment and dementia. We estimated the association between change or constant habits in coffee consumption and the incidence of mild cognitive impairment (MCI). We evaluated 1,445 individuals recruited from 5,632 subjects, aged 65-84 year old, from the Italian Longitudinal Study on Aging, a population-based sample from eight Italian municipalities with a 3.5-year median follow-up. Cognitively normal older individuals who habitually consumed moderate amount of coffee (from 1 to 2 cups of coffee/day) had a lower rate of the incidence of MCI than those who never or rarely consumed coffee [1 cup/day: hazard ratio (HR): 0.47, 95% confidence interval (CI): 0.211 to 1.02 or 1-2 cups/day: HR: 0.31 95% CI: 0.13 to 0.75]. For cognitively normal older subjects who changed their coffee consumption habits, those increasing coffee consumption (>1 cup of coffee/day) had higher rate of the incidence of MCI compared to those with constant habits (up to ±1 cup of coffee/day) (HR: 1.80, 95% CI: 1.11 to 2.92) or those with reduced consumption (<1 cup of coffee/day) (HR: 2.17, 95% CI: 1.16 to 4.08). Finally, there was no significant association between subjects with higher levels of coffee consumption (>2 cups of coffee/day) and the incidence of MCI in comparison with those who never or rarely consumed coffee (HR: 0.26, 95% CI: 0.03 to 2.11). In conclusion, cognitively normal older individuals who increased their coffee consumption had a higher rate of developing MCI, while a constant in time moderate coffee consumption was associated to a reduced rate of the incidence of MCI.

  8. Incidence of cardiac arrhythmias in asymptomatic hereditary hemochromatosis subjects with C282Y homozygosity.

    PubMed

    Shizukuda, Yukitaka; Tripodi, Dorothy J; Zalos, Gloria; Bolan, Charles D; Yau, Yu-Ying; Leitman, Susan F; Waclawiw, Myron A; Rosing, Douglas R

    2012-03-15

    It is not well known whether systemic iron overload per se in hereditary hemochromatosis (HH) is associated with cardiac arrhythmias before other signs and symptoms of cardiovascular disease occur. In the present study, we examined the incidence of cardiac arrhythmia in cardiac asymptomatic subjects with HH (New York Heart Association functional class I) and compared it to that in age- and gender-matched normal volunteers. The 42 subjects with HH and the 19 normal control subjects were recruited through the National Heart, Lung, and Blood Institute-sponsored "Heart Study of Hemochromatosis." They completed 48-hour Holter electrocardiography ambulatory monitoring at the baseline evaluation. The subjects with HH were classified as newly diagnosed (group A) and chronically treated (group B) subjects. All subjects with HH had C282Y homozygosity, and the normal volunteers lacked any HFE gene mutations known to cause HH. Although statistically insignificant, the incidence of ventricular and supraventricular ectopy tended to be greater in the combined HH groups than in the controls. Supraventricular ectopy was more frequently noted in group B compared to in the controls (ectopy rate per hour 11.1 ± 29.9 vs 1.5 ± 3.5, p < 0.05, using the Kruskal-Wallis test). No examples of heart block, other than first-degree atrioventricular node block, were seen in any of the subjects. The incidence of cardiac arrhythmias was not significantly reduced after 6 months of intensive iron removal therapy in the group A subjects. No life-threatening arrhythmias were observed in our subjects with HH. In conclusion, our data suggest that the incidence of cardiac arrhythmias is, at most, marginally increased in asymptomatic subjects with HH. A larger clinical study is warranted to further clarify our observation. Published by Elsevier Inc.

  9. The influence of the platelet count on the incidence of thrombotic and haemorrhagic complications in polycythaemia vera

    PubMed Central

    Dawson, Audrey A.; Ogston, D.

    1970-01-01

    In polycythaemia vera, those patients who have an elevated platelet count develop more thrombotic and more haemorrhagic complications than those with a normal count, even when the haematocrit is maintained by therapy within the normal range. PMID:5416508

  10. Study of the incidence and nature of "very subtle epidermal melasma" in relation to intense pulsed light treatment.

    PubMed

    Negishi, Kei; Kushikata, Nobuharu; Tezuka, Yukiko; Takeuchi, Kaori; Miyamoto, Eiko; Wakamatsu, Shingo

    2004-06-01

    Skin rejuvenation with intense pulsed light (IPL) is effective for clearing epidermal pigment disorders. Complications are mild and limited to epidermal burns caused by excessive settings. Some patients, however, experience IPL-induced melasma-like hyperpigmentation despite the appearance of normal skin. These patients seem to have very subtle epidermal melasma not visible to the naked eye. Ultraviolet photography has been useful in identifying these patients and preventing complications. The study investigated the incidence of very subtle melasma in patients using UV photography, and assessed this tool in identifying high-risk patients. 223 Japanese women, 30-69 years old, participated in the study. Very subtle melasma invisible to the naked eye under normal light was diagnosed by UV photography by two physicians, and any relationship among the disease incidence, age, and regular sunscreen use was examined. Sixty-three cases of very subtle melasma (28.3%) were identified among the 223 subjects, with a significantly lower incidence in sunscreen users. Patients diagnosed with subtle epidermal melasma and treated with mild IPL parameters did not suffer induced secondary hyperpigmentaion. To help avoid complications after treatment, IPL users should be aware of the age and sunscreen-related incidence of this phenomenon in Asian patients.

  11. Meteorological conditions associated with increased incidence of West Nile virus disease in the United States, 2004-2012.

    PubMed

    Hahn, Micah B; Monaghan, Andrew J; Hayden, Mary H; Eisen, Rebecca J; Delorey, Mark J; Lindsey, Nicole P; Nasci, Roger S; Fischer, Marc

    2015-05-01

    West Nile virus (WNV) is a leading cause of mosquito-borne disease in the United States. Annual seasonal outbreaks vary in size and location. Predicting where and when higher than normal WNV transmission will occur can help direct limited public health resources. We developed models for the contiguous United States to identify meteorological anomalies associated with above average incidence of WNV neuroinvasive disease from 2004 to 2012. We used county-level WNV data reported to ArboNET and meteorological data from the North American Land Data Assimilation System. As a result of geographic differences in WNV transmission, we divided the United States into East and West, and 10 climate regions. Above average annual temperature was associated with increased likelihood of higher than normal WNV disease incidence, nationally and in most regions. Lower than average annual total precipitation was associated with higher disease incidence in the eastern United States, but the opposite was true in most western regions. Although multiple factors influence WNV transmission, these findings show that anomalies in temperature and precipitation are associated with above average WNV disease incidence. Readily accessible meteorological data may be used to develop predictive models to forecast geographic areas with elevated WNV disease risk before the coming season. © The American Society of Tropical Medicine and Hygiene.

  12. Numerical Study of Transmission Loss Through a Slow Gas Layer Adjacent to a Plate

    NASA Technical Reports Server (NTRS)

    Schiller, Noah H.; Beck, Benjamin S.; Slagle, Adam C.

    2013-01-01

    This paper describes a systematic numerical investigation of the sound transmission loss through a multilayer system consisting of a bagged gas and lightweight panel. The goal of the study is to better understand the effect of the gas on transmission loss and determine whether a gas with a slow speed of sound is beneficial for noise control applications. As part of the study, the density and speed of sound of the gas are varied independently to assess the impact of each on transmission loss. Results show that near grazing incidence the plane wave transmission loss through the multilayer system is more sensitive to the speed of sound than the density of the gas. In addition, it was found that a slow wave speed in the bagged gas provides more low-frequency transmission loss benefit than a fast wave speed. At low angles of incidence, close to the plate normal, the benefit is due to the reduction of the characteristic impedance of the gas. At high angles of incidence, the benefit is attributed to the fact that the incident waves at the air/gas interface are bent towards the surface normal. Since transmission loss is angle dependent, refraction in the slow gas layer results in a significant improvement in the transmission loss at high angles of incidence.

  13. Measurement of the absorption coefficient using the sound-intensity technique

    NASA Technical Reports Server (NTRS)

    Atwal, M.; Bernhard, R.

    1984-01-01

    The possibility of using the sound intensity technique to measure the absorption coefficient of a material is investigated. This technique measures the absorption coefficient by measuring the intensity incident on the sample and the net intensity reflected by the sample. Results obtained by this technique are compared with the standard techniques of measuring the change in the reverberation time and the standing wave ratio in a tube, thereby, calculating the random incident and the normal incident adsorption coefficient.

  14. Decline in Weight and Incident Mild Cognitive Impairment: Mayo Clinic Study of Aging

    PubMed Central

    Alhurani, Rabe E.; Vassilaki, Maria; Aakre, Jeremiah; Mielke, Michelle M.; Kremers, Walter K.; Machulda, Mary M.; Geda, Yonas E.; Knopman, David S.; Peterson, Ronald C.; Roberts, Rosebud O.

    2016-01-01

    IMPORTANCE Unintentional weight loss has been associated with risk of dementia. Since mild cognitive impairment (MCI) is a prodromal stage for dementia, we sought to evaluate whether changes in weight and body mass index (BMI) may predict incident MCI. OBJECTIVE To investigate the association of change in weight and BMI with risk of MCI. DESIGN, SETTING, AND PARTICIPANTS A population-based, prospective study of participants aged 70 years and older from the Mayo Clinic Study of Aging. Maximum weight and height in midlife (aged 40 to 65 years old) were retrospectively ascertained from the medical records of participants using a medical records linkage system. MAIN OUTCOMES MEASURES Participants were evaluated for cognitive outcomes of normal cognition, MCI, or dementia at baseline and prospectively assessed for incident events at each 15-month evaluation. The association of rate of change in weight and body mass index with risk of MCI was investigated using proportional hazards models. RESULTS Over a mean follow-up of 4.4 years, 524 of 1895 cognitively normal participants developed incident MCI. The mean (standard deviation) rate of weight change per decade from midlife to study entry was greater for individuals who developed incident MCI vs. those who remained cognitively normal (−2.0 (5.1) vs. −1.2 (4.9) kg; p = 0.006). A greater decline in weight per decade was associated with an increased risk of incident MCI (hazard ratio [HR] 95% confidence interval [CI], 1.04 [1.02, 1.06], p < 0.001) after adjusting for sex, education and apolipoprotein E (APOE) ε4 allele. A weight loss of 5 kg/decade corresponds to a 24% increase in risk of MCI (HR=1.24). Higher decline in BMI per decade was also associated with incident MCI (HR, 1.08, 95% CI = [1.03, 1.13], p = 0.003). CONCLUSIONS AND RELEVANCE These findings suggest that declining weight from midlife to late-life is a marker for MCI and may help identify persons at increased risk for MCI. PMID:26831542

  15. Amyloid imaging and CSF biomarkers in predicting cognitive impairment up to 7.5 years later

    PubMed Central

    Fagan, Anne M.; Grant, Elizabeth A.; Hassenstab, Jason; Moulder, Krista L.; Maue Dreyfus, Denise; Sutphen, Courtney L.; Benzinger, Tammie L.S.; Mintun, Mark A.; Holtzman, David M.; Morris, John C.

    2013-01-01

    Objectives: We compared the ability of molecular biomarkers for Alzheimer disease (AD), including amyloid imaging and CSF biomarkers (Aβ42, tau, ptau181, tau/Aβ42, ptau181/Aβ42), to predict time to incident cognitive impairment among cognitively normal adults aged 45 to 88 years and followed for up to 7.5 years. Methods: Longitudinal data from Knight Alzheimer's Disease Research Center participants (N = 201) followed for a mean of 3.70 years (SD = 1.46 years) were used. Participants with amyloid imaging and CSF collection within 1 year of a clinical assessment indicating normal cognition were eligible. Cox proportional hazards models tested whether the individual biomarkers were related to time to incident cognitive impairment. “Expanded” models were developed using the biomarkers and participant demographic variables. The predictive values of the models were compared. Results: Abnormal levels of all biomarkers were associated with faster time to cognitive impairment, and some participants with abnormal biomarker levels remained cognitively normal for up to 6.6 years. No differences in predictive value were found between the individual biomarkers (p > 0.074), nor did we find differences between the expanded biomarker models (p > 0.312). Each expanded model better predicted incident cognitive impairment than the model containing the biomarker alone (p < 0.005). Conclusions: Our results indicate that all AD biomarkers studied here predicted incident cognitive impairment, and support the hypothesis that biomarkers signal underlying AD pathology at least several years before the appearance of dementia symptoms. PMID:23576620

  16. New Microwave-Based Missions Applications for Rainfed Crops Characterization

    NASA Astrophysics Data System (ADS)

    Sánchez, N.; Lopez-Sanchez, J. M.; Arias-Pérez, B.; Valcarce-Diñeiro, R.; Martínez-Fernández, J.; Calvo-Heras, J. M.; Camps, A.; González-Zamora, A.; Vicente-Guijalba, F.

    2016-06-01

    A multi-temporal/multi-sensor field experiment was conducted within the Soil Moisture Measurement Stations Network of the University of Salamanca (REMEDHUS) in Spain, in order to retrieve useful information from satellite Synthetic Aperture Radar (SAR) and upcoming Global Navigation Satellite Systems Reflectometry (GNSS-R) missions. The objective of the experiment was first to identify which radar observables are most sensitive to the development of crops, and then to define which crop parameters the most affect the radar signal. A wide set of radar variables (backscattering coefficients and polarimetric indicators) acquired by Radarsat-2 were analyzed and then exploited to determine variables characterizing the crops. Field measurements were fortnightly taken at seven cereals plots between February and July, 2015. This work also tried to optimize the crop characterization through Landsat-8 estimations, testing and validating parameters such as the leaf area index, the fraction of vegetation cover and the vegetation water content, among others. Some of these parameters showed significant and relevant correlation with the Landsat-derived Normalized Difference Vegetation Index (R>0.60). Regarding the radar observables, the parameters the best characterized were biomass and height, which may be explored for inversion using SAR data as an input. Moreover, the differences in the correlations found for the different crops under study types suggested a way to a feasible classification of crops.

  17. Bone material elasticity in a murine model of osteogenesis imperfecta.

    PubMed

    Mehta, S S; Antich, P P; Landis, W J

    1999-01-01

    To investigate the source of bone brittleness in the disease osteogenesis imperfecta (OI), biomechanical properties have been measured in the femurs from a homozygous (oim/oim) mutant mouse model of OI, its heterozygous littermates, and wild-type animals. The novel technique of ultrasound critical-angle reflectometry (UCR) was used to determine bone material elasticity matrix from measurements of the pressure and shear wave velocity at different orientations about selected points of the bone specimens. This nondestructive method is the only available means for obtaining measurements of this nature from a single surface. The ultrasound pressure wave velocity showed an increased isotropy in the homozygous compared to the wild-type specimens. This was reflected in a significant decrease in the principal elastic modulus measured along the length of the oim/oim bones (E33) while the modulus along the width (E11) did not change significantly, compared to wild-type specimens. The Poisson's ratio, v12, also had a significantly increased value in oim/oim bones. Measurements of these parameters in heterozygous animals generally fell between those from homozygous and control mice. The differences in the elasticity components in oim/oim bones indicate an altered stress distribution and a modified elastic response to loads, compared to normal bone.

  18. Compost quality and its function as a soil conditioner of recultivation layers - a critical review

    NASA Astrophysics Data System (ADS)

    Beck-Broichsitter, Steffen; Fleige, Heiner; Horn, Rainer

    2018-01-01

    During a period of 4 years, soil chemical and physical properties of the temporary capping system in Rastorf (Northern Germany) were estimated, whereby compost was partly used as soil improver in the upper recultivation layer. The air capacity and the available water capacity of soil samples were first determined in 2013 (without compost), and then in 2015 (with compost) under laboratory conditions. Herein, the addition of compost had a positive effect on: the air capacity up to 13.4 cm3 cm-3; and the available water capacity up to 20.1 cm3 cm-3 in 2015, in the recultivation layer (0-20 cm). However, taking into account the in situ results of the tensiometer and frequency domain reflectometry measurements, the addition of compost had a negative effect. The soil-compost mixture led to restricted remoistening even after a normal summer drying period in autumn and induced more negative matric potentials in the recultivation layer. In summary, the soil-improving effect of the compost addition, in conjunction with an increased water storage capacity, is undeniable and was demonstrated in a combined field and laboratory study. Therefore, intensive hydrophobicity can inhibit the homogeneous remoistening of the soil, resulting in a decreased hydraulic effectiveness of the sealing system.

  19. In vivo detection of nanometer-scale structural changes of the human tympanic membrane in otitis media.

    PubMed

    Dsouza, Roshan; Won, Jungeun; Monroy, Guillermo L; Hill, Malcolm C; Porter, Ryan G; Novak, Michael A; Boppart, Stephen A

    2018-06-08

    Otitis media (OM) is a common ear infection and a leading cause of conductive hearing loss in the pediatric population. Current technologies such as otoscopy, pneumatic otoscopy, tympanometry, and acoustic reflectometry are used to diagnose OM, which can reasonably diagnose the infection with a sensitivity and specificity of 50-90% and 60-90%, respectively. However, these techniques provide limited information about the physical architecture of the tympanic membrane (TM), or what may lie behind it. Here, we report the detection of nanometer-scale structural changes of the TM using nano-sensitive optical coherence tomography (nsOCT). In total, an image dataset from 65 pediatric subjects from three different groups (normal, acute OM, and chronic OM) and with longitudinal image-based analysis of ear infections were included in this study. The nsOCT data were correlated with physician diagnosis and with OCT thickness measurements and were found to be in good agreement with these results. We report that nsOCT detects in vivo structural deformations of the TM earlier than OCT alone, and enhances the detection sensitivity of OCT measurements. This unique technique for early detection of nano-scale structural modifications in the TM has the potential to aid in our understanding of microbiological effects, and possibly for early diagnosis and more effective treatment of OM.

  20. Optical Performance Modeling of FUSE Telescope Mirror

    NASA Technical Reports Server (NTRS)

    Saha, Timo T.; Ohl, Raymond G.; Friedman, Scott D.; Moos, H. Warren

    2000-01-01

    We describe the Metrology Data Processor (METDAT), the Optical Surface Analysis Code (OSAC), and their application to the image evaluation of the Far Ultraviolet Spectroscopic Explorer (FUSE) mirrors. The FUSE instrument - designed and developed by the Johns Hopkins University and launched in June 1999 is an astrophysics satellite which provides high resolution spectra (lambda/Delta(lambda) = 20,000 - 25,000) in the wavelength region from 90.5 to 118.7 nm The FUSE instrument is comprised of four co-aligned, normal incidence, off-axis parabolic mirrors, four Rowland circle spectrograph channels with holographic gratings, and delay line microchannel plate detectors. The OSAC code provides a comprehensive analysis of optical system performance, including the effects of optical surface misalignments, low spatial frequency deformations described by discrete polynomial terms, mid- and high-spatial frequency deformations (surface roughness), and diffraction due to the finite size of the aperture. Both normal incidence (traditionally infrared, visible, and near ultraviolet mirror systems) and grazing incidence (x-ray mirror systems) systems can be analyzed. The code also properly accounts for reflectance losses on the mirror surfaces. Low frequency surface errors are described in OSAC by using Zernike polynomials for normal incidence mirrors and Legendre-Fourier polynomials for grazing incidence mirrors. The scatter analysis of the mirror is based on scalar scatter theory. The program accepts simple autocovariance (ACV) function models or power spectral density (PSD) models derived from mirror surface metrology data as input to the scatter calculation. The end product of the program is a user-defined pixel array containing the system Point Spread Function (PSF). The METDAT routine is used in conjunction with the OSAC program. This code reads in laboratory metrology data in a normalized format. The code then fits the data using Zernike polynomials for normal incidence systems or Legendre-Fourier polynomials for grazing incidence systems. It removes low order terms from the metrology data, calculates statistical ACV or PSD functions, and fits these data to OSAC models for the scatter analysis. In this paper we briefly describe the laboratory image testing of FUSE spare mirror performed in the near and vacuum ultraviolet at John Hopkins University and OSAC modeling of the test setup performed at NASA/GSFC. The test setup is a double-pass configuration consisting of a Hg discharge source, the FUSE off-axis parabolic mirror under test, an autocollimating flat mirror, and a tomographic imaging detector. Two additional, small fold flats are used in the optical train to accommodate the light source and the detector. The modeling is based on Zernike fitting and PSD analysis of surface metrology data measured by both the mirror vendor (Tinsley) and JHU. The results of our models agree well with the laboratory imaging data, thus validating our theoretical model. Finally, we predict the imaging performance of FUSE mirrors in their flight configuration at far-ultraviolet wavelengths.

  1. TDR water content inverse profiling in layered soils during infiltration and evaporation

    NASA Astrophysics Data System (ADS)

    Greco, R.; Guida, A.

    2009-04-01

    During the last three decades, time domain reflectometry (TDR) has become one of the most commonly used tools for soil water content measurements either in laboratory or in the field. Indeed, TDR provides easy and cheap water content estimations with relatively small disturbance to the investigated soil. TDR measurements of soil water content are based on the strong correlation between relative dielectric permittivity of wet soil and its volumetric water content. Several expressions of the relationship between relative dielectric permittivity and volumetric water content have been proposed, empirically stated (Topp et al., 1980) as well as based on semi-analytical approach to dielectric mixing models (Roth et al., 1990; Whalley, 1993). So far, TDR field applications suffered the limitation due to the capability of the technique of estimating only the mean water content in the volume investigated by the probe. Whereas the knowledge of non homogeneous vertical water content profiles was needed, it was necessary to install either several vertical probes of different length or several horizontal probes placed in the soil at different depths, in both cases strongly increasing soil disturbance as well as the complexity of the measurements. Several studies have been recently dedicated to the development of inversion methods aimed to extract more information from TDR waveforms, in order to estimate non homogeneous moisture profiles along the axis of the metallic probe used for TDR measurements. A common feature of all these methods is that electromagnetic transient through the wet soil along the probe is mathematically modelled, assuming that the unknown soil water content distribution corresponds to the best agreement between simulated and measured waveforms. In some cases the soil is modelled as a series of small layers with different dielectric properties, and the waveform is obtained as the result of the superposition of multiple reflections arising from impedance discontinuities between the layers (Nguyen et al., 1997; Todoroff et al., 1998; Heimovaara, 2001; Moret et al., 2006). Other methods consider the dielectric properties of the soil as smoothly variable along probe axis (Greco, 1999; Oswald et al., 2003; Greco, 2006). Aim of the study is testing the applicability to layered soils of the inverse method for the estimation of water content profiles along vertical TDR waveguides, originally applied in laboratory to homogeneous soil samples with monotonic moisture distributions (Greco, 2006), and recently extended to field measurements with more general water content profiles (Greco and Guida, 2008). Influence of soil electrical conductivity, uniqueness of solution, choices of parametrization, parameters identifiabilty, sensitivity of the method to chosen parameters variations are discussed. Finally, the results of the application of the inverse method to a series of infiltration and evaporation experiments carried out in a flume filled with three soil layers of different physical characteristics are presented. ACKNOWLEDGEMENTS The research was co-financed by the Italian Ministry of University, by means of the PRIN 2006 PRIN program, within the research project entitled ‘Definition of critical rainfall thresholds for destructive landslides for civil protection purposes'. REFERENCES Greco, R., 1999. Measurement of water content profiles by single TDR experiments. In: Feyen, J., Wiyo, K. (Eds.), Modelling of Transport Processes in Soils. Wageningen Pers, Wageningen, the Netherlands, pp. 276-283. Greco, R., 2006. Soil water content inverse profiling from single TDR waveforms. J. Hydrol. 317, 325-339. Greco R., Guida A., 2008. Field measurements of topsoil moisture profiles by vertical TDR probes. J. Hydrol. 348, 442- 451. Heimovaara, T.J., 2001. Frequency domain modelling of TDR waveforms in order to obtain frequency dependent dielectric properties of soil samples: a theoretical approach. In: TDR 2001 - Second International Symposium on Time Domain Reflectometry for Innovative Geotechnical Applications. Northwestern University, Evanston, Illinois, pp. 19-21. Moret, D., Arrue, J.L., Lopez, M.V., Gracia, R., 2006. A new TDR waveform analysis approach for soil moisture profiling using a single probe. J. Hydrol. 321, 163-172. Nguyen, B.L., Bruining, J., Slob, E.C., 1997. Saturation profiles from dielectric (frequency domain reflectometry) measurements in porous media. In: Proceedings of International Workshop on characterization and Measurements of the Hydraulic Properties of Unsaturated Porous Media, Riverside, California, pp. 363-375. Oswald, B., Benedickter, H.R., Ba¨chtold, W., Flu¨hler, H., 2003. Spatially resolved water content profiles from inverted time domain reflectometry signals. Water Resour. Res. 39 (12), 1357. Todoroff, P., Lorion, R., Lan Sun Luk, J.-D., 1998. L'utilisation des génétiques pour l'identification de profils hydriques de sol a` partir de courbes réflectométriques. CR Acad. Sci. Paris, Sciences de la terre et des plane`tes 327, 607-610. Topp, G.C., Davis, J.L., Annan, A.P., 1980. Electromagnetic determination of soil water content: measurement in coaxial transmission lines. Water Resour. Res. 16, 574-582. Roth, K., Schulin, R., Fluhler, H., Attinger, W., 1990. Calibration of time domain reflectometry for water content measurement using a composite dielectric approach. Water Resour. Res. 26, 2267-2273. Whalley, W.R., 1993. Considerations on the use of time domain reflectometry (TDR) for measuring soil water content. J. Soil Sci. 44, 1-9.

  2. Choice of fluid therapy in patients of craniopharyngioma in the perioperative period: A hospital-based preliminary study

    PubMed Central

    Mukherjee, K. K.; Dutta, Pinaki; Singh, Apinderpreet; Gupta, Prakamya; Srinivasan, Anand; Bhagat, Hemant; Mathuriya, S. N.; Shah, Viral N.; Bhansali, Anil

    2014-01-01

    Background: Electrolyte imbalance and acute diabetes insipidus (DI) are the most common complications in patients undergoing craniopharyngioma surgery. Improper management of water and electrolyte imbalance is common cause of morbidity and mortality. Data is sparse and controversial regarding the choice of fluid therapy in this population during perioperative period. Methods: In this retrospective-prospective study involving 73 patients (58 retrospective), the type of fluid therapy was correlated with occurrence of hypernatremia, hyponatremia, DI, morbidity, and mortality. In the retrospective study, 48 patients received normal saline and 10 received mixed fluids as per the prevailing practice. In the prospective group, five patients each received normal saline, half normal saline, and 5% dextrose randomly. Results: The sodium values were significantly higher in first 48 h in the group that received normal saline compared with other groups (P < 0.001). The use of normal saline was associated with higher incidence of hypernatremia, DI, and mortality (P = 0.05), while the group that received 5% dextrose was associated with hyponatremia, hypoglycemia, and seizures. There was no perioperative hypotension with use of any of the fluids. Conclusion: Our results indicate half normal saline was fluid of choice with diminished incidence of water and electrolyte abnormalities without increase in mortality during postoperative period. PMID:25101200

  3. Solar cell angle of incidence corrections

    NASA Technical Reports Server (NTRS)

    Burger, Dale R.; Mueller, Robert L.

    1995-01-01

    Literature on solar array angle of incidence corrections was found to be sparse and contained no tabular data for support. This lack along with recent data on 27 GaAs/Ge 4 cm by 4 cm cells initiated the analysis presented in this paper. The literature cites seven possible contributors to angle of incidence effects: cosine, optical front surface, edge, shadowing, UV degradation, particulate soiling, and background color. Only the first three are covered in this paper due to lack of sufficient data. The cosine correction is commonly used but is not sufficient when the incident angle is large. Fresnel reflection calculations require knowledge of the index of refraction of the coverglass front surface. The absolute index of refraction for the coverglass front surface was not known nor was it measured due to lack of funds. However, a value for the index of refraction was obtained by examining how the prediction errors varied with different assumed indices and selecting the best fit to the set of measured values. Corrections using front surface Fresnel reflection along with the cosine correction give very good predictive results when compared to measured data, except there is a definite trend away from predicted values at the larger incident angles. This trend could be related to edge effects and is illustrated by a use of a box plot of the errors and by plotting the deviation of the mean against incidence angle. The trend is for larger deviations at larger incidence angles and there may be a fourth order effect involved in the trend. A chi-squared test was used to determine if the measurement errors were normally distributed. At 10 degrees the chi-squared test failed, probably due to the very small numbers involved or a bias from the measurement procedure. All other angles showed a good fit to the normal distribution with increasing goodness-of-fit as the angles increased which reinforces the very small numbers hypothesis. The contributed data only went to 65 degrees from normal which prevented any firm conclusions about extreme angle effects although a trend in the right direction was seen. Measurement errors were estimated and found to be consistent with the conclusions that were drawn. A controlled experiment using coverglasses and cells from the same lots and extending to larger incidence angles would probably lead to further insight into the subject area.

  4. Observations of explosion generated PcP spectra at near-normal incidence

    NASA Astrophysics Data System (ADS)

    Niazi, Mansour; McLaughlin, Keith L.

    1987-10-01

    Short period recordings of PcP at the SRO station ANTO have been observed at epicentral distance of 13.5° from presumed underground explosions in western Kazahk, USSR. The core reflections are narrow band (0.6 to 2.4 Hz), short duration (3 sec) signals. Comparison of these near normally incident reflections to P waveforms observed at greater distances reveals that the PcP spectra are peaked with respect to the more representative P-wave spectra. The 1.2 Hz spectral peak is also observed for PcP waves recorded at 50 degrees. Corrections for frequency independent mantle Q attnuation models only increase the high frequency deficiency of the PcP spectra at frequencies above 1.2 Hz. A plausible explanation calls for finer structural features of core-mantle boundary (CMB) than hitherto suggested. The influence of small scale lateral heterogeneities, however, cannot be completely ruled out. (Mantle-core boundary, near normal PcP reflection.)

  5. The retrocuspid papilla. A clinical survey.

    PubMed

    Berman, F R; Fay, J T

    1976-07-01

    1. As mentioned previously in the literature, RCPs are commonly found in the young but become progressively less evident with advancing age. 2. The incidence of the RCP in Negroes is approximately the same as that in Caucasians. 3. Bilateral RCPs are more common than unilateral papillae. 4. The occurrence of RCPs is consistently more common in females than in males, in both Caucasians and Negroes. 5. Histologically, the RCPs are essentially normal, showing features indicative of those seen in frictional irritation during mastication and phonation. 6. The 72.5 per cent incidence of RCPs in children under 11 years of age confirms the trends of past studies and indicates that the RCP is a normal entity in pediatric dental patients and should be included in the literature as such. 7. The clinical significance of the RCP is that it be recognized as a normal anatomic structure that regresses with age and requires no treatment.

  6. Associations of maternal pre-pregnancy underweight with small-for-gestational-age and spontaneous preterm birth, and optimal gestational weight gain in Japanese women.

    PubMed

    Fujiwara, Kana; Aoki, Shigeru; Kurasawa, Kentaro; Okuda, Mika; Takahashi, Tsuneo; Hirahara, Fumiki

    2014-04-01

    To determine associations of maternal pre-pregnancy underweight with poor outcomes and evaluate how gestational weight gain affects risks for such outcomes in pre-pregnancy underweight Japanese women. By analyzing the January 2001-December 2012 hospital database, we retrospectively identified 6954 women with pre-pregnancy normal weights (body mass index, 18.5-24.9 kg/m²) and 1057 pre-pregnancy underweight women (body mass index, <18.5 kg/m²) who delivered at the Perinatal Maternity and Neonatal Center of Yokohama City University. These women were stratified by weekly weight gain during the second/third trimesters to investigate associations of gestational weight gain with spontaneous preterm birth and small for gestational age (SGA). Spontaneous preterm birth and SGA incidences were compared with those of women meeting Institute of Medicine (IO M) guidelines to determine optimal weight gain in Japanese women. Preterm birth and SGA incidences were significantly higher in pre-pregnancy underweight than in pre-pregnancy normal weight women (4.6% vs 2.4% [P=0.005] and 13.9% vs 9.7% [P = 0.003], respectively). For pre-pregnancy normal weight women, preterm birth incidence was significantly higher in those with weight gain of less than 0.2 kg/week than in those IOM guidelines. For pre-pregnancy underweight women, preterm birth and SGA incidences were significantly higher in those with weight gain of less than 0.3 kg/week than in those meeting IOM guidelines. Preterm birth and SGA incidences did not differ significantly between pre-pregnancy normal weight women with weight gain of 0.2 kg/week or more and pre-pregnancy underweight women with weight gain of 0.3 kg/week or more, as compared to women meeting IOM guidelines. These results suggest that IOM guidelines for gestational weight gain may lack external validity in Japanese women. © 2014 The Authors. Journal of Obstetrics and Gynaecology Research © 2014 Japan Society of Obstetrics and Gynecology.

  7. Characteristics of plasma scalds in multilayer dielectric films

    NASA Astrophysics Data System (ADS)

    Liu, Xiaofeng; Zhao, Yuan'an; Li, Dawei; Hu, Guohang; Gao, Yanqi; Fan, Zhengxiu; Shao, Jianda

    2011-07-01

    Plasma scalding is one of the most typical laser damage morphologies induced by a nanosecond laser with a wavelength of 1053nm in HfO2/SiO2 multilayer films. In this paper, the characteristics of plasma scalds are systematically investigated with multiple methods. The scalding behaves as surface discoloration under a microscope. The shape is nearly circular when the laser incidence angle is close to normal incidence and is elliptical at oblique incidence. The nodular-ejection pit is in the center of the scalding region when the laser irradiates at the incidence angle close to normal incidence and in the right of the scalding region when the laser irradiates from left to right at oblique incidence. The maximum damage size of the scalding increases with laser energy. The edge of the scalding is high compared with the unirradiated film surface, and the region tending to the center is concave. Plasma scald is proved to be surface damage. The maximum depth of a scald increases with its size. Tiny pits of nanometer scale can be seen in the scalding film under a scanning electronic microscope at a higher magnification. The absorptions of the surface plasma scalds tend to be approximately the same as the lower absorptions of test sites without laser irradiation. Scalds do not grow during further illumination pulses until 65J/cm2. The formation of surface plasma scalding may be related to the occurrence of the laser-supported detonation wave.

  8. A technique for detecting and locating polarisation nonuniformities in an anisotropic optical fibre

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Burdin, V V; Konstantinov, Yurii A; Pervadchuk, Vladimir P

    2013-06-30

    One of the most important requirements for optical fibres as waveguiding media is uniformity. Polarisation-maintaining anisotropic fibres contain a special type of nonuniformity, which leads to polarisation cross-talk: optical power is transferred from one polarisation mode to the orthogonal mode. In this paper, we report a technique for detecting and locating such nonuniformities in a PANDA anisotropic single-mode fibre using polarised reflectometry. (fiber optics)

  9. Recharge monitoring in an interplaya setting

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Scanlon, B.R.; Reedy, R.C.; Liang, J.

    1999-03-01

    The objective of this investigation is to monitor infiltration in response to precipitation events in an interplaya setting. The authors evaluated data gathered from the interplaya recharge monitoring installation at the Pantex Plant from March through December 1998. They monitored thermocouple psychrometer (TCP) instruments to measure water potential and time-domain reflectometry (TDR) probes to measure water content and bulk soil conductivity. Heat-dissipation sensor (HDS) instruments were monitored to supplement the TCP data.

  10. Nondestructive evaluation of composite materials by pulsed time domain methods in imbedded optical fibers

    NASA Technical Reports Server (NTRS)

    Claus, R. O.; Bennett, K. D.; Jackson, B. S.

    1986-01-01

    The application of fiber-optical time domain reflectometry (OTDR) to nondestructive quantitative measurements of distributed internal strain in graphite-epoxy composites, using optical fiber waveguides imbedded between plies, is discussed. The basic OTDR measurement system is described, together with the methods used to imbed optical fibers within composites. Measurement results, system limitations, and the effect of the imbedded fiber on the integrity of the host composite material are considered.

  11. Usefulness of Maintaining a Normal Electrocardiogram Over Time for Predicting Cardiovascular Health.

    PubMed

    Soliman, Elsayed Z; Zhang, Zhu-Ming; Chen, Lin Y; Tereshchenko, Larisa G; Arking, Dan; Alonso, Alvaro

    2017-01-15

    We hypothesized that maintaining a normal electrocardiogram (ECG) status over time is associated with low cardiovascular (CV) disease in a dose-response fashion and subsequently could be used to monitor programs aimed at promoting CV health. This analysis included 4,856 CV disease-free participants from the Atherosclerosis Risk in Communities study who had a normal ECG at baseline (1987 to 1989) and complete electrocardiographic data in subsequent 3 visits (1990 to 1992, 1993 to 1995, and 1996 to 1998). Participants were classified based on maintaining their normal ECG status during these 4 visits into "maintained," "not maintained," or "inconsistent" normal ECG status as defined by the Minnesota ECG classification. CV disease events (coronary heart disease, heart failure, and stroke) were adjudicated from Atherosclerosis Risk in Communities visit-4 through 2010. Over a median follow-up of 13.2 years, 885 CV disease events occurred. The incidence rate of CV disease events was lowest among study participants who maintained a normal ECG status, followed by those with an inconsistent pattern, and then those who did not maintain their normal ECG status (trend p value <0.001). Similarly, the greater the number of visits with a normal ECG status, the lower was the incidence rate of CV disease events (trend p value <0.001). Maintaining (vs not maintaining) a normal ECG status was associated with a lower risk of CV disease, which was lower than that observed in those with inconsistent normal ECG pattern (trend p value <0.01). In conclusion, maintaining a normal ECG status over time is associated with low risk of CV disease in a dose-response fashion, suggesting its potential use as a monitoring tool for programs promoting CV health. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. Monitoring stream stage, channel profile, and aqueous conductivity with time domain reflectometry (TDR).

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brainard, James Robert; Tidwell, Vincent Carroll; Coplen, Amy K.

    2004-11-01

    Time domain reflectometry (TDR) operates by propagating a radar frequency electromagnetic pulse down a transmission line while monitoring the reflected signal. As the electromagnetic pulse propagates along the transmission line, it is subject to impedance by the dielectric properties of the media along the transmission line (e.g., air, water, sediment), reflection at dielectric discontinuities (e.g., air-water or water-sediment interface), and attenuation by electrically conductive materials (e.g., salts, clays). Taken together, these characteristics provide a basis for integrated stream monitoring; specifically, concurrent measurement of stream stage, channel profile and aqueous conductivity. Here, we make novel application of TDR within the contextmore » of stream monitoring. Efforts toward this goal followed three critical phases. First, a means of extracting the desired stream parameters from measured TDR traces was required. Analysis was complicated by the fact that interface location and aqueous conductivity vary concurrently and multiple interfaces may be present at any time. For this reason a physically based multisection model employing the S11 scatter function and Cole-Cole parameters for dielectric dispersion and loss was developed to analyze acquired TDR traces. Second, we explored the capability of this multisection modeling approach for interpreting TDR data acquired from complex environments, such as encountered in stream monitoring. A series of laboratory tank experiments were performed in which the depth of water, depth of sediment, and conductivity were varied systematically. Comparisons between modeled and independently measured data indicate that TDR measurements can be made with an accuracy of {+-}3.4x10{sup -3} m for sensing the location of an air/water or water/sediment interface and {+-}7.4% of actual for the aqueous conductivity. Third, monitoring stations were sited on the Rio Grande and Paria rivers to evaluate performance of the TDR system under normal field conditions. At the Rio Grande site (near Central Bridge in Albuquerque, New Mexico) continuous monitoring of stream stage and aqueous conductivity was performed for 6 months. Additionally, channel profile measurements were acquired at 7 locations across the river. At the Paria site (near Lee's Ferry, Arizona) stream stage and aqueous conductivity data were collected over a 4-month period. Comparisons drawn between our TDR measurements and USGS gage data indicate that the stream stage is accurate within {+-}0.88 cm, conductivity is accurate within {+-}11% of actual, and channel profile measurements agree within {+-}1.2 cm.« less

  13. EUNIS; Extreme-Ultraviolet Normal-Incidence Spectrometer

    NASA Technical Reports Server (NTRS)

    Thomas, Roger J.; Davila, Joseph M.; Fisher, Richard R. (Technical Monitor)

    2001-01-01

    GSFC is in the process of assembling an Extreme-Ultraviolet Normal Incidence Spectrometer called EUNIS, to be flown as a sounding rocket payload. The instrument builds on the many technical innovations pioneered by our highly successful SERTS experiment, which has now flown a total of ten times, most recently last summer. The new design will have somewhat improved spatial and spectral resolutions, as well as two orders of magnitude greater sensitivity, permitting high signal/noise EUV spectroscopy with a temporal resolution near 1 second for the first time ever. In order to achieve such high time cadence, a novel detector system is being developed, based on Active-Pixel-Sensor electronics, a key component of our design.

  14. The effect of detonation wave incidence angle on the acceleration of flyers by explosives heavily laden with inert additives

    NASA Astrophysics Data System (ADS)

    Loiseau, Jason; Georges, William; Frost, David L.; Higgins, Andrew J.

    2017-01-01

    The incidence angle of a detonation wave in a conventional high explosive influences the acceleration and terminal velocity of a metal flyer by increasing the magnitude of the material velocity imparted by the transmitted shock wave as the detonation is tilted towards normal loading. For non-ideal explosives heavily loaded with inert additives, the detonation velocity is typically subsonic relative to the flyer sound speed, leading to shockless accelerations when the detonation is grazing. Further, in a grazing detonation the particles are initially accelerated in the direction of the detonation and only gain velocity normal to the initial orientation of the flyer at later times due to aerodynamic drag as the detonation products expand. If the detonation wave in a non-ideal explosive instead strikes the flyer at normal incidence, a shock is transmitted into the flyer and the first interaction between the particle additives and the flyer occurs due to the imparted material velocity from the passage of the detonation wave. Consequently, the effect of incidence angle and additive properties may play a more prominent role in the flyer acceleration. In the present study we experimentally compared normal detonation loadings to grazing loadings using a 3-mm-thick aluminum slapper to impact-initiate a planar detonation wave in non-ideal explosive-particle admixtures, which subsequently accelerated a second 6.4-mm-thick flyer. Flyer acceleration was measured with heterodyne laser velocimetry (PDV). The explosive mixtures considered were packed beds of glass or steel particles of varying sizes saturated with sensitized nitromethane, and gelled nitromethane mixed with glass microballoons. Results showed that the primary parameter controlling changes in flyer velocity was the presence of a transmitted shock, with additive density and particle size playing only secondary roles. These results are similar to the grazing detonation experiments, however under normal loading the largest, higher density particles yielded the highest terminal flyer velocity, whereas in the grazing experiments the larger, low density particles yielded the highest terminal velocity.

  15. Effects of strain on Goos-Hänchen shifts of monolayer phosphorene

    NASA Astrophysics Data System (ADS)

    Li, Kaihui; Cheng, Fang

    2018-03-01

    We investigate the Goos-Hänchen(GH) shift for ballistic electrons (i) reflected from a step-like inhomogeneity of strain, and (ii) transmitted through a monolayer phosphoresce junction consisting of a positive strained region and two normal regions (or a normal region and two negative strained regions). Refraction occurs at the interface between the unstrained/positive-strain(negative-strain/unstrained), in analogy with optical refraction. The critical angle is different for different strengths and directions of the strains. The critical angles for electrons tunneling through unstrained/positive-strain junction can even decrease to zero when the positive strain exceeds a critical value. For the monolayer phosphorene junction consisting of a positive strain region and two normal regions (or a normal region and two negative strain regions), we find that the GH shifts resonantly depends on the middle region width. The resonant values and the plus-minus sign of the displacement can be controlled by the incident angle, incident energy and the strain. These properties will be useful for the applications in phosphorene-based electronic devices.

  16. Application of the wavenumber jump condition to the normal and oblique interaction of a plane acoustic wave and a plane shock

    NASA Technical Reports Server (NTRS)

    Kleinstein, G. G.; Gunzburger, M. D.

    1977-01-01

    The kinematics of normal and oblique interactions between a plane acoustic wave and a plane shock wave are investigated separately using an approach whereby the shock is considered as a sharp discontinuity surface separating two half-spaces, so that the dispersion relation on either side of the shock and the wavenumber jump condition across a discontinuity surface completely specify the kinematics of the problem in the whole space independently of the acoustic-field dynamics. The normal interaction is analyzed for a stationary shock, and the spectral change of the incident wave is investigated. The normal interaction is then examined for the case of a shock wave traveling into an ambient region where an acoustic disturbance is propagating in the opposite direction. Detailed attention is given to the consequences of the existence of a critical shock speed above which the frequency of the transmitted wave becomes negative. Finally, the oblique interaction with a fixed shock is considered, and the existence and nature of the transmitted wave is investigated, particularly as a function of the angle of incidence.

  17. Higher incidence of small Y chromosome in humans with trisomy 21 (Down syndrome).

    PubMed

    Verma, R S; Huq, A; Madahar, C; Qazi, Q; Dosik, H

    1982-09-01

    The length of the Y chromosome was measured in 42 black patients with trisomy 21 (47,XY,+21) and a similar number of normal individuals of American black ancestry. The length of the Y was expressed as a function of Y/F ratio and arbitrarily classified into five groups using subjectively defined criteria as follows: very small, small, average, large, and very large. Thirty-eight % of the trisomy 21 patients had small or very small Ys compared to 2.38% of the controls (P less than 0.01). In both populations the size of the Y was not normally distributed. In the normals it was skewed to the left, whereas in the Downs the distribution was flat (platykurtic). A significantly higher incidence of Y length heteromorphisms was noted in the Down as compared to the normal black population. In the light of our current understanding that about one-third of all trisomy 21 patients are due to paternal nondisjunction, it may be tempting to speculate that males with small Y are at an increased risk for nondisjunction of the 21 chromosome.

  18. Breaking the Silence: Power, Conflict, and Contested Frames within an Affluent High School

    ERIC Educational Resources Information Center

    Howard, Adam; EnglandKennedy, Elizabeth

    2006-01-01

    This article examines an incident between male student athletes within a locker room at a private school. The reaction of many in this school community to this incident reveals that "hazing" rituals were normally ignored or condoned by many of the parents, coaches, administrators, and teachers who were aware of them. These attitudes changed when…

  19. Electric Fields in Earth Orbital Space.

    DTIC Science & Technology

    1984-09-01

    region. Further work on propagation of these fields within the magneto- sphere and on a quantitative examination of their oblique incidence on the...9 1.6 Technical Summary ................................... 13 2 FUTURE WORK .............................................. 16 2.1 Oblique Incidence...ambient or sector structure field normally lies in the ecliptic plane and either points away or toward the sun at the classic "garden hose, angle. It has

  20. Enhanced broadband absorption in nanowire arrays with integrated Bragg reflectors

    NASA Astrophysics Data System (ADS)

    Aghaeipour, Mahtab; Pettersson, Håkan

    2018-05-01

    A near-unity unselective absorption spectrum is desirable for high-performance photovoltaics. Nanowire (NW) arrays are promising candidates for efficient solar cells due to nanophotonic absorption resonances in the solar spectrum. The absorption spectra, however, display undesired dips between the resonance peaks. To achieve improved unselective broadband absorption, we propose to enclose distributed Bragg reflectors (DBRs) in the bottom and top parts of indium phosphide (InP) NWs, respectively. We theoretically show that by enclosing only two periods of In0.56Ga0.44As/InP DBRs, an unselective 78% absorption efficiency (72% for NWs without DBRs) is obtained at normal incidence in the spectral range from 300 nm to 920 nm. Under oblique light incidence, the absorption efficiency is enhanced up to about 85% at an incidence angle of 50°. By increasing the number of DBR periods from two to five, the absorption efficiency is further enhanced up to 95% at normal incidence. In this work, we calculated optical spectra for InP NWs, but the results are expected to be valid for other direct band gap III-V semiconductor materials. We believe that our proposed idea of integrating DBRs in NWs offers great potential for high-performance photovoltaic applications.

  1. Investigation of angular dependence on photonic bandgap for 1-D photonic crystal

    NASA Astrophysics Data System (ADS)

    Nigam, Anjali; Suthar, B.; Bhargava, A.; Vijay, Y. K.

    2018-05-01

    In the present communication, we study the one-dimensional photonic crystal structure. The photonic band structure has been obtained using Plane Wave Expansion Method (PWEM). The studied has been extended to investigate the angular dependence on photonic bandgap for 1-D photonic crystal. The photonic bandgap is same both for TE and TM mode for normal incidence, while both mode move separate with an incidence angle. The photonic bandgap is almost unaffected with angle for TE mode while the bandgap decreases with an incidence angle for TM mode.

  2. Radiation effects in silicon and gallium arsenide solar cells using isotropic and normally incident radiation

    NASA Technical Reports Server (NTRS)

    Anspaugh, B. E.; Downing, R. G.

    1984-01-01

    Several types of silicon and gallium arsenide solar cells were irradiated with protons with energies between 50 keV and 10 MeV at both normal and isotropic incidence. Damage coefficients for maximum power relative to 10 MeV were derived for these cells for both cases of omni-directional and normal incidence. The damage coefficients for the silicon cells were found to be somewhat lower than those quoted in the Solar Cell Radiation Handbook. These values were used to compute omni-directional damage coefficients suitable for solar cells protected by coverglasses of practical thickness, which in turn were used to compute solar cell degradation in two proton-dominated orbits. In spite of the difference in the low energy proton damage coefficients, the difference between the handbook prediction and the prediction using the newly derived values was negligible. Damage coefficients for GaAs solar cells for short circuit current, open circuit voltage, and maximum power were also computed relative to 10 MeV protons. They were used to predict cell degradation in the same two orbits and in a 5600 nmi orbit. Results show the performance of the GaAs solar cells in these orbits to be superior to that of the Si cells.

  3. An ultrasonic method for determination of elastic moduli, density, attenuation and thickness of a polymer coating on a stiff plate.

    PubMed

    Lavrentyev, A I; Rokhlin, S I

    2001-04-01

    An ultrasonic method proposed by us for determination of the complete set of acoustical and geometrical properties of a thin isotropic layer between semispaces (J. Acoust. Soc. Am. 102 (1997) 3467) is extended to determination of the properties of a coating on a thin plate. The method allows simultaneous determination of the coating thickness, density, elastic moduli and attenuation (longitudinal and shear) from normal and oblique incidence reflection (transmission) frequency spectra. Reflection (transmission) from the coated plate is represented as a function of six nondimensional parameters of the coating which are determined from two experimentally measured spectra: one at normal and one at oblique incidence. The introduction of the set of nondimensional parameters allows one to transform the reconstruction process from one search in a six-dimensional space to two searches in three-dimensional spaces (one search for normal incidence and one for oblique). Thickness, density, and longitudinal and shear elastic moduli of the coating are calculated from the nondimensional parameters determined. The sensitivity of the method to individual properties and its stability against experimental noise are studied and the inversion algorithm is accordingly optimized. An example of the method and experimental measurement for comparison is given for a polypropylene coating on a steel foil.

  4. A novel approach for studying submarine faults: the FOCUS project (FOCUS = Fiber Optic Cable Use for Seafloor studies of earthquake hazard and deformation)

    NASA Astrophysics Data System (ADS)

    Gutscher, M. A.; Royer, J. Y.; Graindorge, D.; Murphy, S.; Klingelhoefer, F.; Cattaneo, A.; Barreca, G.; Quetel, L.; Petersen, F.; Riccobene, G.; Urlaub, M.; Krastel, S.; Gross, F.; Kopp, H.

    2017-12-01

    Two-thirds of the earth's surface is covered by water and thus largely inaccessible to modern networks of seismological instruments. A novel use of fiber optic cables could help improve hazard assessment and increase early warning capability. Laser reflectometry using BOTDR (Brillouin Optical Time Domain Reflectometry), commonly used for structural health monitoring of large-scale engineering structures (e.g. - bridges, dams, pipelines, etc.) can measure very small strains (< 1 mm) at very large distances (10 - 200 km). This technique has never been used to monitor deformation caused by active faults on the seafloor. The objective of the FOCUS project is to demonstrate that this technique can measure small (1 - 2 cm) displacements on a primary test site offshore Sicily where the recently mapped North Alfeo Fault crosses the Catania EMSO seafloor observatory, 28 km long fiber optic cable. Two other EMSO test sites with fiber optic cables, the 100 km long Capo Passero (SE Sicily) and the 2 km long cable off Molene Island (W France) will also be studied. Initial reflectometry tests were performed on these three cables using a Febus BOTDR interrogator in June and July 2017. Unexpectedly high dynamic noise levels (corresponding to strains of 200 - 500 mm/m) were observed on the Molene cable, likely due to the high-energy, shallow water, open ocean environment. The tests on the EMSO infrastructure in Sicily indicated low experimental noise levels (20 - 30 mm/m) out to a distance of 15 km. BOTDR observations will have to be calibrated by other independent measurements. Therefore, targeted marine geophysical surveys of the seafloor along the trace of the cable and faults are planned, with the use of seafloor geodetic instruments to quantify fault displacement. Once the BOTDR fault-monitoring technique has been tested, demonstrated and calibrated offshore Eastern Sicily, the goal is to expand it to other fiber optic cable networks, either existing research networks in earthquake hazard zones (Japan, Cascadia) or to the Mediterranean region through access to retired (decommissioned) telecommunication cables or development of dual-use cables (two of the anticipated outcomes of the FOCUS project). This represents a potentially tremendous breakthrough in seismology, tectonics and natural hazard early warning capability.

  5. Energetic electrons driven in the polarization direction of an intense laser beam incident normal to a solid target

    DOE PAGES

    Seely, J. F.; Hudson, L. T.; Pereira, N.; ...

    2016-02-24

    Experiments were performed at the LLNL Titan laser to measure the propagation direction of the energetic electrons that were generated during the interaction of the polarized laser beam with solid targets in the case of normal incidence. The energetic electrons propagated through vacuum to spectator metal wires in the polarization direction and in the perpendicular direction, and the K shell spectra from the different wire materials were recorded as functions of the distance from the laser focal spot. It was found that the fluence of the energetic electrons driven into the spectator wires in the polarization direction compared to themore » perpendicular direction was larger and increased with the distance from the focal spot. Finally, this indicates that energetic electrons are preferentially driven in the direction of the intense oscillating electric field of the incident laser beam in agreement with the multiphoton inverse Bremsstrahlung absorption process.« less

  6. Surface patterning of GaAs under irradiation with very heavy polyatomic Au ions

    NASA Astrophysics Data System (ADS)

    Bischoff, L.; Böttger, R.; Heinig, K.-H.; Facsko, S.; Pilz, W.

    2014-08-01

    Self-organization of surface patterns on GaAs under irradiation with heavy polyatomic Au ions has been observed. The patterns depend on the ion mass, and the substrate temperature as well as the incidence angle of the ions. At room temperature, under normal incidence the surface remains flat, whereas above 200 °C nanodroplets of Ga appear after irradiation with monatomic, biatomic as well as triatomic Au ions of kinetic energies in the range of 10-30 keV per atom. In the intermediate temperature range of 100-200 °C meander- and dot-like patterns form, which are not related to Ga excess. Under oblique ion incidence up to 45° from the surface normal, at room temperature the surface remains flat for mon- and polyatomic Au ions. For bi- and triatomic ions in the range of 60° ≤ α ≤ 70° ripple patterns have been found, which become shingle-like for α ≥ 80°, whereas the surface remains flat for monatomic ions.

  7. Quantum transport in new two-dimensional heterostructures: Thin films of topological insulators, phosphorene

    NASA Astrophysics Data System (ADS)

    Majidi, Leyla; Zare, Moslem; Asgari, Reza

    2018-06-01

    The unusual features of the charge and spin transport characteristics are investigated in new two-dimensional heterostructures. Intraband specular Andreev reflection is realized in a topological insulator thin film normal/superconducting junction in the presence of a gate electric field. Perfect specular electron-hole conversion is shown for different excitation energy values in a wide experimentally available range of the electric field and also for all angles of incidence when the excitation energy has a particular value. It is further demonstrated that the transmission probabilities of the incoming electrons from different spin subbands to the monolayer phosphorene ferromagnetic/normal/ferromagnetic (F/N/F) hybrid structure have different behavior with the angle of incidence and perfect transmission occurs at defined angles of incidence to the proposed structure with different length of the N region, and different alignments of magnetization vectors. Moreover, the sign change of the spin-current density is demonstrated by tuning the chemical potential and exchange field of the F region.

  8. Strain in shore fast ice due to incoming ocean waves and swell

    NASA Astrophysics Data System (ADS)

    Fox, Colin; Squire, Vernon A.

    1991-03-01

    Using a development from the theoretical model presented by Fox and Squire (1990), this paper investigates the strain field generated in shore fast ice by normally incident ocean waves and swell. After a brief description of the model and its convergence, normalized absolute strain (relative to a 1-m incident wave) is found as a function of distance from the ice edge for various wave periods, ice thicknesses, and water depths. The squared transfer function, giving the relative ability of incident waves of different periods to generate strain in the ice, is calculated, and its consequences are discussed. The ice is then forced with a Pierson-Moskowitz spectrum, and the consequent strain spectra are plotted as a function of penetration into the ice sheet. Finally, rms strain, computed as the incoherent sum of the strains resulting from energy in the open water spectrum, is found. The results have implications to the breakup of shore fast ice and hence to the floe size distribution of the marginal ice zone.

  9. Intersubband absorption in Si(1-x)Ge(x/Si superlattices for long wavelength infrared detectors

    NASA Technical Reports Server (NTRS)

    Rajakarunanayake, Yasantha; Mcgill, Tom C.

    1990-01-01

    Researchers calculated the absorption strengths for intersubband transitions in n-type Si(1-x)Ge(x)/Si superlattices. These transitions can be used for the detection of long-wavelength infrared radiation. A significant advantage in Si(1-x)Ge(x)/Si supperlattice detectors is the ability to detect normally incident light; in Ga(1-x)Al(x)As/GaAs superlattices, intersubband absorption is possible only if the incident light contains a polarization component in the growth direction of the superlattice. Researchers present detailed calculation of absorption coefficients, and peak absorption wavelengths for (100), (111) and (110) Si(1-x)Ge(x)/Si superlattices. Peak absorption strengths of about 2000 to 6000 cm(exp -1) were obtained for typical sheet doping concentrations (approx. equals 10(exp 12)cm(exp -2)). Absorption comparable to that in Ga(1-x)Al(x)As/GaAs superlattice detectors, compatibility with existing Si technology, and the ability to detect normally incident light make these devices promising for future applications.

  10. Surface-wave potential for triggering tectonic (nonvolcanic) tremor

    USGS Publications Warehouse

    Hill, D.P.

    2010-01-01

    Source processes commonly posed to explain instances of remote dynamic triggering of tectonic (nonvolcanic) tremor by surface waves include frictional failure and various modes of fluid activation. The relative potential for Love- and Rayleigh-wave dynamic stresses to trigger tectonic tremor through failure on critically stressed thrust and vertical strike-slip faults under the Coulomb-Griffith failure criteria as a function of incidence angle is anticorrelated over the 15- to 30-km-depth range that hosts tectonic tremor. Love-wave potential is high for strike-parallel incidence on low-angle reverse faults and null for strike-normal incidence; the opposite holds for Rayleigh waves. Love-wave potential is high for both strike-parallel and strike-normal incidence on vertical, strike-slip faults and minimal for ~45?? incidence angles. The opposite holds for Rayleigh waves. This pattern is consistent with documented instances of tremor triggered by Love waves incident on the Cascadia mega-thrust and the San Andreas fault (SAF) in central California resulting from shear failure on weak faults (apparent friction, ????? 0.2). However, documented instances of tremor triggered by surface waves with strike-parallel incidence along the Nankai megathrust beneath Shikoku, Japan, is associated primarily with Rayleigh waves. This is consistent with the tremor bursts resulting from mixed-mode failure (crack opening and shear failure) facilitated by near-lithostatic ambient pore pressure, low differential stress, with a moderate friction coefficient (?? ~ 0.6) on the Nankai subduction interface. Rayleigh-wave dilatational stress is relatively weak at tectonic tremor source depths and seems unlikely to contribute significantly to the triggering process, except perhaps for an indirect role on the SAF in sustaining tremor into the Rayleigh-wave coda that was initially triggered by Love waves.

  11. Surface-wave potential for triggering tectonic (nonvolcanic) tremor-corrected

    USGS Publications Warehouse

    Hill, David P.

    2012-01-01

    Source processes commonly posed to explain instances of remote dynamic triggering of tectonic (nonvolcanic) tremor by surface waves include frictional failure and various modes of fluid activation. The relative potential for Love- and Rayleigh-wave dynamic stresses to trigger tectonic tremor through failure on critically stressed thrust and vertical strike-slip faults under the Coulomb-Griffith failure criteria as a function of incidence angle are anticorrelated over the 15- to 30-km-depth range that hosts tectonic tremor. Love-wave potential is high for strike-parallel incidence on low-angle reverse faults and null for strike-normal incidence; the opposite holds for Rayleigh waves. Love-wave potential is high for both strike-parallel and strike-normal incidence on vertical, strike-slip faults and minimal for ~45° incidence angles. The opposite holds for Rayleigh waves. This pattern is consistent with documented instances of tremor triggered by Love waves incident on the Cascadia megathrust and the San Andreas fault (SAF) in central California resulting from shear failure on weak faults (apparent friction is μ* ≤ 0:2). Documented instances of tremor triggered by surface waves with strike-parallel incidence along the Nankai megathrust beneath Shikoku, Japan, however, are associated primarily with Rayleigh waves. This is consistent with the tremor bursts resulting from mixed-mode failure (crack opening and shear failure) facilitated by near-lithostatic ambient pore pressure, low differential stress, with a moderate friction coefficient (μ ~ 0:6) on the Nankai subduction interface. Rayleigh-wave dilatational stress is relatively weak at tectonic tremor source depths and seems unlikely to contribute significantly to the triggering process, except perhaps for an indirect role on the SAF in sustaining tremor into the Rayleigh-wave coda that was initially triggered by Love waves.

  12. Coffee consumption and the incidence of type 2 diabetes in men and women with normal glucose tolerance: The Strong Heart Study

    PubMed Central

    Zhang, Ying; Lee, Elisa T.; Cowan, Linda D.; Fabsitz, Richard R.; Howard, Barbara V.

    2009-01-01

    Background and aims It was reported that high coffee consumption was related to decreased diabetes risk. The aim of this study is to examine the association between coffee consumption and the incidence of type 2 diabetes in persons with normal glucose tolerance in a population with a high incidence and prevalence of diabetes. Methods and results In a prospective cohort study, information about daily coffee consumption was collected at the baseline examination (1989-1992) in a population-based sample of American Indian men and women 45-74 years of age. Participants with normal glucose tolerance (N=1141) at the baseline examination were followed for an average of 7.6 years. The incidence of diabetes was compared across the categories of daily coffee consumption. The hazard ratios of diabetes related to coffee consumption were calculated using Cox proportional hazards models, adjusted for potential confounders. Levels of coffee consumption were positively related to levels of current smoking and inversely related to body mass index, waist circumference, female gender, and hypertension. Compared to those who did not drink coffee, participants who drank 12 or more cups of coffee daily had 67% less risk of developing diabetes during the follow-up (hazard ratio: 0.33, 95% confidence interval: 0.13, 0.81). Conclusion In this population, a high level of coffee consumption was associated with a reduced risk of deterioration of glucose metabolism over an average 7.6 years of follow-up. More work is needed to understand whether there is a plausible biological mechanism for this observation. PMID:20171062

  13. Risk of invasive cervical cancer after atypical glandular cells in cervical screening: nationwide cohort study.

    PubMed

    Wang, Jiangrong; Andrae, Bengt; Sundström, Karin; Ström, Peter; Ploner, Alexander; Elfström, K Miriam; Arnheim-Dahlström, Lisen; Dillner, Joakim; Sparén, Pär

    2016-02-11

    To investigate the risks of invasive cervical cancer after detection of atypical glandular cells (AGC) during cervical screening. Nationwide population based cohort study. Cancer and population registries in Sweden. 3,054,328 women living in Sweden at any time between 1 January 1980 and 1 July 2011 who had any record of cervical cytological testing at ages 23-59. Of these, 2,899,968 women had normal cytology results at the first screening record. The first recorded abnormal result was atypical glandular cells (AGC) in 14 625, high grade squamous intraepithelial lesion (HSIL) in 65 633, and low grade squamous intraepithelial lesions (LSIL) in 244 168. Cumulative incidence of invasive cervical cancer over 15.5 years; proportion of invasive cervical cancer within six months of abnormality (prevalence); crude incidence rates for invasive cervical cancer over 0.5-15.5 years of follow-up; incidence rate ratios compared with women with normal cytology, estimated with Poisson regression adjusted for age and stratified by histopathology of cancer; distribution of clinical assessment within six months after the abnormality. The prevalence of cervical cancer was 1.4% for women with AGC, which was lower than for women with HSIL (2.5%) but higher than for women with LSIL (0.2%); adenocarcinoma accounted for 73.2% of the prevalent cases associated with AGC. The incidence rate of invasive cervical cancer after AGC was significantly higher than for women with normal results on cytology for up to 15.5 years and higher than HSIL and LSIL for up to 6.5 years. The incidence rate of adenocarcinoma was 61 times higher than for women with normal results on cytology in the first screening round after AGC, and remained nine times higher for up to 15.5 years. Incidence and prevalence of invasive cervical cancer was highest when AGC was found at ages 30-39. Only 54% of women with AGC underwent histology assessment within six months, much less than after HSIL (86%). Among women with histology assessment within six months, the incidence rate of cervical cancer after AGC was significantly higher than that after HSIL for up to 6.5 years. AGC found at cervical screening is associated with a high and persistent risk of cervical cancer for up to 15 years, particularly for cervical adenocarcinoma and women with AGC at age 30-39. Compared with the reduction in risk of cancer seen after HSIL management, management of AGC seems to have been suboptimal in preventing cervical cancer. Research to optimise management is needed, and a more aggressive assessment strategy is warranted. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  14. Risk of invasive cervical cancer after atypical glandular cells in cervical screening: nationwide cohort study

    PubMed Central

    Andrae, Bengt; Sundström, Karin; Ström, Peter; Ploner, Alexander; Elfström, K Miriam; Arnheim-Dahlström, Lisen; Dillner, Joakim; Sparén, Pär

    2016-01-01

    Objectives To investigate the risks of invasive cervical cancer after detection of atypical glandular cells (AGC) during cervical screening. Design Nationwide population based cohort study. Setting Cancer and population registries in Sweden. Participants 3 054 328 women living in Sweden at any time between 1 January 1980 and 1 July 2011 who had any record of cervical cytological testing at ages 23-59. Of these, 2 899 968 women had normal cytology results at the first screening record. The first recorded abnormal result was atypical glandular cells (AGC) in 14 625, high grade squamous intraepithelial lesion (HSIL) in 65 633, and low grade squamous intraepithelial lesions (LSIL) in 244 168. Main outcome measures Cumulative incidence of invasive cervical cancer over 15.5 years; proportion of invasive cervical cancer within six months of abnormality (prevalence); crude incidence rates for invasive cervical cancer over 0.5-15.5 years of follow-up; incidence rate ratios compared with women with normal cytology, estimated with Poisson regression adjusted for age and stratified by histopathology of cancer; distribution of clinical assessment within six months after the abnormality. Results The prevalence of cervical cancer was 1.4% for women with AGC, which was lower than for women with HSIL (2.5%) but higher than for women with LSIL (0.2%); adenocarcinoma accounted for 73.2% of the prevalent cases associated with AGC. The incidence rate of invasive cervical cancer after AGC was significantly higher than for women with normal results on cytology for up to 15.5 years and higher than HSIL and LSIL for up to 6.5 years. The incidence rate of adenocarcinoma was 61 times higher than for women with normal results on cytology in the first screening round after AGC, and remained nine times higher for up to 15.5 years. Incidence and prevalence of invasive cervical cancer was highest when AGC was found at ages 30-39. Only 54% of women with AGC underwent histology assessment within six months, much less than after HSIL (86%). Among women with histology assessment within six months, the incidence rate of cervical cancer after AGC was significantly higher than that after HSIL for up to 6.5 years. Conclusions AGC found at cervical screening is associated with a high and persistent risk of cervical cancer for up to 15 years, particularly for cervical adenocarcinoma and women with AGC at age 30-39. Compared with the reduction in risk of cancer seen after HSIL management, management of AGC seems to have been suboptimal in preventing cervical cancer. Research to optimise management is needed, and a more aggressive assessment strategy is warranted. PMID:26869597

  15. Electromagnetic Inverse Problems Involving Distributions of Dielectric Mechanisms and Parameters

    DTIC Science & Technology

    2005-08-17

    0220 and in part by the National Institute of Aerospace (NIA) and NASA under grant NIA/NCSU-03-01-2536-NC. The authors would like to thank Dr. Richard...Albanese of the AFRL, Brooks AFB, and Dr. William P. Winfree, NASA Langley Research Center, for their valuable comments and suggestions during the...foods investigated by time-domain reflectometry , J. Food Science 68 (2003), 1396-1403. [46] P.G. Petropoulos, On the time-domain response of Cole-Cole

  16. International Conference on Millimeter Wave and Far-Infrared Technology (1st) Held in Beijing, China, August 17-21, 1992

    DTIC Science & Technology

    1993-03-01

    I1. NON COHERENT-REFLECTOMETRY The design of sources of steady-state intencive noise signals of mm wave band with sufficiently wide and homogenious...structures exhibit non -reciprocity effects, as well as magnetically controlled resonances, which are observable in reflection, absorption, and...performance of the oscillator. Accordingly, we designed a 3mm electronically tuned harmonic -420- oscillator in which it is easy to debug and control

  17. Airborne Observation of Ocean Surface Roughness Variations Using a Combination of Microwave Radiometer and Reflectometer Systems: The Second Virginia Offshore (Virgo II) Experiment

    DTIC Science & Technology

    2014-03-06

    from scattered satellite transmissions, was first demonstrated using Global Navigation Satellite System ( GNSS ) reflections. Recently, reflectometry has...Earth’s atmosphere. The 2012 GNSS +R workshop provided an opportunity for engineers and Earth scientists to assess the state of the art, demonstrate new...bi-static radar technique utilizes signals of opportunity transmitted from existing L-band Global Navigation Satellite Systems ( GNSS ), including GPS

  18. Method and apparatus for distributed sensing of volatiles using a long period fiber grating sensor with modulated plastic coating for environmental monitoring

    NASA Technical Reports Server (NTRS)

    Ponce, Adrian (Inventor); Kossakovski, Dmitri A. (Inventor); Bearman, Gregory H. (Inventor)

    2010-01-01

    Optical time domain reflectometry caused by absorption of a volatile or analyte into the fiber optic cladding is used as an optical nose. The fiber optics (14) are covered with a gas permeable film (44) which is patterned to leave millimeter wide gas permeable notches (48a-48d). The notches contain a sensing polymer that responds to different gases by expanding or contracting.

  19. Continuous-wave ultrasound reflectometry for surface roughness imaging applications

    PubMed Central

    Kinnick, R. R.; Greenleaf, J. F.; Fatemi, M.

    2009-01-01

    Background Measurement of surface roughness irregularities that result from various sources such as manufacturing processes, surface damage, and corrosion, is an important indicator of product quality for many nondestructive testing (NDT) industries. Many techniques exist, however because of their qualitative, time-consuming and direct-contact modes, it is of some importance to work out new experimental methods and efficient tools for quantitative estimation of surface roughness. Objective and Method Here we present continuous-wave ultrasound reflectometry (CWUR) as a novel nondestructive modality for imaging and measuring surface roughness in a non-contact mode. In CWUR, voltage variations due to phase shifts in the reflected ultrasound waves are recorded and processed to form an image of surface roughness. Results An acrylic test block with surface irregularities ranging from 4.22 μm to 19.05 μm as measured by a coordinate measuring machine (CMM), is scanned by an ultrasound transducer having a diameter of 45 mm, a focal distance of 70 mm, and a central frequency of 3 MHz. It is shown that CWUR technique gives very good agreement with the results obtained through CMM inasmuch as the maximum average percent error is around 11.5%. Conclusion Images obtained here demonstrate that CWUR may be used as a powerful noncontact and quantitative tool for nondestructive inspection and imaging of surface irregularities at the micron-size level with an average error of less than 11.5%. PMID:18664399

  20. Optical coherence tomography and optical coherence domain reflectometry for deep brain stimulation probe guidance

    NASA Astrophysics Data System (ADS)

    Jeon, Sung W.; Shure, Mark A.; Baker, Kenneth B.; Chahlavi, Ali; Hatoum, Nagi; Turbay, Massud; Rollins, Andrew M.; Rezai, Ali R.; Huang, David

    2005-04-01

    Deep Brain Stimulation (DBS) is FDA-approved for the treatment of Parkinson's disease and essential tremor. Currently, placement of DBS leads is guided through a combination of anatomical targeting and intraoperative microelectrode recordings. The physiological mapping process requires several hours, and each pass of the microelectrode into the brain increases the risk of hemorrhage. Optical Coherence Domain Reflectometry (OCDR) in combination with current methodologies could reduce surgical time and increase accuracy and safety by providing data on structures some distance ahead of the probe. For this preliminary study, we scanned a rat brain in vitro using polarization-insensitive Optical Coherence Tomography (OCT). For accurate measurement of intensity and attenuation, polarization effects arising from tissue birefringence are removed by polarization diversity detection. A fresh rat brain was sectioned along the coronal plane and immersed in a 5 mm cuvette with saline solution. OCT images from a 1294 nm light source showed depth profiles up to 2 mm. Light intensity and attenuation rate distinguished various tissue structures such as hippocampus, cortex, external capsule, internal capsule, and optic tract. Attenuation coefficient is determined by linear fitting of the single scattering regime in averaged A-scans where Beer"s law is applicable. Histology showed very good correlation with OCT images. From the preliminary study using OCT, we conclude that OCDR is a promising approach for guiding DBS probe placement.

Top