Critical laboratory values in hemostasis: toward consensus.
Lippi, Giuseppe; Adcock, Dorothy; Simundic, Ana-Maria; Tripodi, Armando; Favaloro, Emmanuel J
2017-09-01
The term "critical values" can be defined to entail laboratory test results that significantly lie outside the normal (reference) range and necessitate immediate reporting to safeguard patient health, as well as those displaying a highly and clinically significant variation compared to previous data. The identification and effective communication of "highly pathological" values has engaged the minds of many clinicians, health care and laboratory professionals for decades, since these activities are vital to good laboratory practice. This is especially true in hemostasis, where a timely and efficient communication of critical values strongly impacts patient management. Due to the heterogeneity of available data, this paper is hence aimed to analyze the state of the art and provide an expert opinion about the parameters, measurement units and alert limits pertaining to critical values in hemostasis, thus providing a basic document for future consultation that assists laboratory professionals and clinicians alike. KEY MESSAGES Critical values are laboratory test results significantly lying outside the normal (reference) range and necessitating immediate reporting to safeguard patient health. A broad heterogeneity exists about critical values in hemostasis worldwide. We provide here an expert opinion about the parameters, measurement units and alert limits pertaining to critical values in hemostasis.
Normal value range is 105 to 333 international units per liter (IU/L). Normal value ranges may vary slightly among different laboratories. Some labs use different measurements or test different samples. Talk to your provider about ...
Lack of grading agreement among international hemostasis external quality assessment programs
Olson, John D.; Jennings, Ian; Meijer, Piet; Bon, Chantal; Bonar, Roslyn; Favaloro, Emmanuel J.; Higgins, Russell A.; Keeney, Michael; Mammen, Joy; Marlar, Richard A.; Meley, Roland; Nair, Sukesh C.; Nichols, William L.; Raby, Anne; Reverter, Joan C.; Srivastava, Alok; Walker, Isobel
2018-01-01
Laboratory quality programs rely on internal quality control and external quality assessment (EQA). EQA programs provide unknown specimens for the laboratory to test. The laboratory's result is compared with other (peer) laboratories performing the same test. EQA programs assign target values using a variety of methods statistical tools and performance assessment of ‘pass’ or ‘fail’ is made. EQA provider members of the international organization, external quality assurance in thrombosis and hemostasis, took part in a study to compare outcome of performance analysis using the same data set of laboratory results. Eleven EQA organizations using eight different analytical approaches participated. Data for a normal and prolonged activated partial thromboplastin time (aPTT) and a normal and reduced factor VIII (FVIII) from 218 laboratories were sent to the EQA providers who analyzed the data set using their method of evaluation for aPTT and FVIII, determining the performance for each laboratory record in the data set. Providers also summarized their statistical approach to assignment of target values and laboratory performance. Each laboratory record in the data set was graded pass/fail by all EQA providers for each of the four analytes. There was a lack of agreement of pass/fail grading among EQA programs. Discordance in the grading was 17.9 and 11% of normal and prolonged aPTT results, respectively, and 20.2 and 17.4% of normal and reduced FVIII results, respectively. All EQA programs in this study employed statistical methods compliant with the International Standardization Organization (ISO), ISO 13528, yet the evaluation of laboratory results for all four analytes showed remarkable grading discordance. PMID:29232255
Sanz-Peláez, O; Angel-Moreno, A; Tapia-Martín, M; Conde-Martel, A; Carranza-Rodríguez, C; Carballo-Rastrilla, S; Soria-López, A; Pérez-Arellano, J L
2008-09-01
The progressive increase in the number of immigrants to Spain in recent years has made it necessary for health-care professionals to be aware about the specific characteristics of this population. An attempt is made in this study to define the normal range of common laboratory values in healthy sub-Saharan adults. Common laboratory values were studied (blood cell counts, clotting tests and blood biochemistry values) and were measured in 150 sub-Saharan immigrants previously defined as healthy according to a complete health evaluation that included a clinical history, physical examination, serologic tests and study of stool parasites. These results were compared to those from a control group consisting of 81 age-and-sex matched healthy blood donors taken from the Spanish native population. Statistically significant differences were obtained in the following values. Mean corpuscular volume (MCV), red cell distribution width (RDW), total leukocytes, and serum levels of creatinine, uric acid, total protein content, creatin-kinase (CK), aspartate aminotransferase (AST), gamma-glutamyl-transpeptidase (GGT), Immunoglobulin G (IgG) and M (IgM). If evaluated according to the normal values in native people, a considerable percentage of healthy sub-Saharan immigrants would present
Standardization of ¹³¹I: implementation of CIEMAT/NIST method at BARC, India.
Kulkarni, D B; Anuradha, R; Reddy, P J; Joseph, Leena
2011-10-01
The CIEMAT/NIST efficiency tracing method using ³H standard was implemented at Radiation Safety Systems Division, Bhabha Atomic Research Centre (BARC) for the standardization of ¹³¹I radioactive solution. Measurements were also carried out using the 4π β-γ coincidence counting system maintained as a primary standard at the laboratory. The implementation of the CIEMAT/NIST method was verified by comparing the activity concentration obtained in the laboratory with that of the average value of the APMP intercomparison (Yunoki et al., in progress, (APMP.RI(II)-K2.I-131)). The results obtained by the laboratory is linked to the CIPM Key Comparison Reference Value (KCRV) through the equivalent activity value of National Metrology Institute of Japan (NMIJ) (Yunoki et al., in progress, (APMP.RI(II)-K2.I-131)), which was the pilot laboratory for the intercomparison. The procedure employed to standardize ¹³¹I by the CIEMAT/NIST efficiency tracing technique is presented. The activity concentrations obtained have been normalized with the activity concentration measured by NMIJ to maintain confidentiality of results until the Draft-A report is accepted by all participants. The normalized activity concentrations obtained with the CIEMAT/NIST method was 0.9985 ± 0.0035 kBq/g and using 4π β-γ coincidence counting method was 0.9909 ± 0.0046 kBq/g as on 20 March 2009, 0 h UTC. The normalized activity concentration measured by the NMIJ was 1 ± 0.0024 kBq/g. The normalized average of the activity concentrations of all the participating laboratories was 1.004 ± 0.028 kBq/g. The results obtained in the laboratory are comparable with the other international standards within the uncertainty limits. Copyright © 2011 Elsevier Ltd. All rights reserved.
A normal result means there was no growth of microorganisms on the lab dish. Normal value ranges may vary slightly among different laboratories. Talk to your doctor about the meaning of your specific test results.
... thinning medicine does not work. Normal Results Normal value ranges may vary slightly among different laboratories. Talk ... to the principles of the Health on the Net Foundation (www.hon.ch). The information provided herein ...
The normal range is 3.4 to 5.4 g/dL (34 to 54 g/L). Normal value ranges may vary slightly among different laboratories. Some labs use different measurements or test different samples. Talk to your provider about ...
Aspartate aminotransferase (AST) blood test
The normal range is 10 to 34 U/L (0.17 to 0.57 µkat/L). Normal value ranges may vary slightly among different laboratories. Some labs use different measurements or may test different samples. Talk to your health ...
Interlaboratory comparison of reference materials for nitrogen-isotope-ratio measurements
Böhlke, John Karl; Coplen, Tyler B.
1995-01-01
Aliquots of seven different reference materials were distributed for an interlaboratory comparison of stable nitrogen-isotope-ratio measurements. Results from 15 laboratories were compiled and evaluated selectively to yield provisional values of 515N for each material, i, with respect to atmospheric N2 (o1SN,7air). The 515N values reported by the different laboratories are correlated in such a way that some of the major discrepancies may be removed by normalization (/. e., by altering the length of the ô N scale for each laboratory by an amount defined by local measurements of reference materials with extreme values).
NASA Astrophysics Data System (ADS)
Sanchez, Gerardo
A flipped laboratory model involves significant preparation by the students on lab material prior to entry to the laboratory. This allows laboratory time to be focused on active learning through experiments. The aim of this study was to observe changes in student performance through the transition from a traditional laboratory format, to a flipped format. The data showed that for both Anatomy and Physiology (I and II) laboratories a more normal distribution of grades was observed once labs were flipped and lecture grade averages increased. Chi square and analysis of variance tests showed grade changes to a statistically significant degree, with a p value of less than 0.05 on both analyses. Regression analyses gave decreasing numbers after the flipped labs were introduced with an r. 2 value of .485 for A&P I, and .564 for A&P II. Results indicate improved scores for the lecture part of the A&P course, decreased outlying scores above 100, and all score distributions approached a more normal distribution.
Predictive value and efficiency of laboratory testing.
Galen, R S
1980-11-01
Literature on determining reference values and reference intervals on "normal" or "healthy" individuals is abundant. It is impossible, however, to evaluate a data set of reference values and select a suitable reference interval that will be meaningful for the practice of medicine. The reference interval, no matter how derived statistically, tells us nothing about disease. This is the main reason the concepts of "normal values" have failed us and why "reference values" will prove similarly disappointing. By studying these same constituents in a variety of disease states as well, it will be possible to select "referent values" that will make the test procedure meaningful for diagnostic purposes. In order to obtain meaningful referent values for predicting disease, it is necessary to study not only the "healthy" reference population, but patients with the disease in question, and patients who are free of the disease in question but who have other diseases. Studies of this type are not frequently found for laboratory tests that are in common use today.
Hematological reference values of healthy Malaysian population.
Roshan, T M; Rosline, H; Ahmed, S A; Rapiaah, M; Wan Zaidah, A; Khattak, M N
2009-10-01
Health and disease can only be distinguished by accurate and reliable reference values of a particular laboratory test. It is now a proven fact that there is considerable variation in hematology reference intervals depending on the demographic and preanalytical variables. There are evidences that values provided by manufacturers do not have appropriate application for all populations. Moreover, reference ranges provided by different laboratory manuals and books also do not solve this problem. We are presenting here normal reference ranges of Malaysian population. These values were determined by using Sysmex XE-2100 and ACL 9000 hematology and coagulation analyzers. Results from this study showed that there were considerable differences in the reference values from manufacturers, western population or laboratory manuals compared with those from the local population.
Serum chromium level normally is less than or equal to 1.4 micrograms/milliliter (µg/mL) or 26924.80 nanomoles/L (nmol/L). Normal value ranges may vary slightly among different laboratories. Talk to your provider about the meaning of your specific test result.
The normal range is 40 to 140 units per liter (U/L) or 0.38 to 1.42 microkat/L (µkat/L). Note: Normal value ranges may vary slightly among different laboratories. Talk to your provider about the meaning of your specific test results. The examples ...
42 CFR 493.1251 - Standard: Procedure manual.
Code of Federal Regulations, 2013 CFR
2013-10-01
... (CONTINUED) STANDARDS AND CERTIFICATION LABORATORY REQUIREMENTS Quality System for Nonwaived Testing Analytic... intervals (normal values). (11) Imminently life-threatening test results, or panic or alert values. (12... reporting patient results including, when appropriate, the protocol for reporting imminently life...
42 CFR 493.1251 - Standard: Procedure manual.
Code of Federal Regulations, 2014 CFR
2014-10-01
... (CONTINUED) STANDARDS AND CERTIFICATION LABORATORY REQUIREMENTS Quality System for Nonwaived Testing Analytic... intervals (normal values). (11) Imminently life-threatening test results, or panic or alert values. (12... reporting patient results including, when appropriate, the protocol for reporting imminently life...
42 CFR 493.1251 - Standard: Procedure manual.
Code of Federal Regulations, 2010 CFR
2010-10-01
... (CONTINUED) STANDARDS AND CERTIFICATION LABORATORY REQUIREMENTS Quality System for Nonwaived Testing Analytic... intervals (normal values). (11) Imminently life-threatening test results, or panic or alert values. (12... reporting patient results including, when appropriate, the protocol for reporting imminently life...
Isokuortti, Elina; Zhou, You; Peltonen, Markku; Bugianesi, Elisabetta; Clement, Karine; Bonnefont-Rousselot, Dominique; Lacorte, Jean-Marc; Gastaldelli, Amalia; Schuppan, Detlef; Schattenberg, Jörn M; Hakkarainen, Antti; Lundbom, Nina; Jousilahti, Pekka; Männistö, Satu; Keinänen-Kiukaanniemi, Sirkka; Saltevo, Juha; Anstee, Quentin M; Yki-Järvinen, Hannele
2017-10-01
Recent European guidelines for non-alcoholic fatty liver disease (NAFLD) call for reference values for HOMA-IR. In this study, we aimed to determine: (1) the upper limit of normal HOMA-IR in two population-based cohorts; (2) the HOMA-IR corresponding to NAFLD; (3) the effect of sex and PNPLA3 genotype at rs738409 on HOMA-IR; and (4) inter-laboratory variations in HOMA-IR. We identified healthy individuals in two population-based cohorts (FINRISK 2007 [n = 5024] and the Programme for Prevention of Type 2 Diabetes in Finland [FIN-D2D; n = 2849]) to define the upper 95th percentile of HOMA-IR. Non-obese individuals with normal fasting glucose levels, no excessive alcohol use, no known diseases and no use of any drugs were considered healthy. The optimal HOMA-IR cut-off for NAFLD (liver fat ≥5.56%, based on the Dallas Heart Study) was determined in 368 non-diabetic individuals (35% with NAFLD), whose liver fat was measured using proton magnetic resonance spectroscopy ( 1 H-MRS). Samples from ten individuals were simultaneously analysed for HOMA-IR in seven European laboratories. The upper 95th percentiles of HOMA-IR were 1.9 and 2.0 in healthy individuals in the FINRISK (n = 1167) and FIN-D2D (n = 459) cohorts. Sex or PNPLA3 genotype did not influence these values. The optimal HOMA-IR cut-off for NAFLD was 1.9 (sensitivity 87%, specificity 79%). A HOMA-IR of 2.0 corresponded to normal liver fat (<5.56% on 1 H-MRS) in linear regression analysis. The 2.0 HOMA-IR measured in Helsinki corresponded to 1.3, 1.6, 1.8, 1.8, 2.0 and 2.1 in six other laboratories. The inter-laboratory CV% of HOMA-IR was 25% due to inter-assay variation in insulin (25%) rather than glucose (5%) measurements. The upper limit of HOMA-IR in population-based cohorts closely corresponds to that of normal liver fat. Standardisation of insulin assays would be the first step towards definition of normal values for HOMA-IR.
... common measurements for results of these tests. Normal value ranges may vary slightly among different laboratories. Some labs use different measurements or test different samples. Talk to your health ...
Yoon, Dukyong; Schuemie, Martijn J; Kim, Ju Han; Kim, Dong Ki; Park, Man Young; Ahn, Eun Kyoung; Jung, Eun-Young; Park, Dong Kyun; Cho, Soo Yeon; Shin, Dahye; Hwang, Yeonsoo; Park, Rae Woong
2016-03-01
Distributed research networks (DRNs) afford statistical power by integrating observational data from multiple partners for retrospective studies. However, laboratory test results across care sites are derived using different assays from varying patient populations, making it difficult to simply combine data for analysis. Additionally, existing normalization methods are not suitable for retrospective studies. We normalized laboratory results from different data sources by adjusting for heterogeneous clinico-epidemiologic characteristics of the data and called this the subgroup-adjusted normalization (SAN) method. Subgroup-adjusted normalization renders the means and standard deviations of distributions identical under population structure-adjusted conditions. To evaluate its performance, we compared SAN with existing methods for simulated and real datasets consisting of blood urea nitrogen, serum creatinine, hematocrit, hemoglobin, serum potassium, and total bilirubin. Various clinico-epidemiologic characteristics can be applied together in SAN. For simplicity of comparison, age and gender were used to adjust population heterogeneity in this study. In simulations, SAN had the lowest standardized difference in means (SDM) and Kolmogorov-Smirnov values for all tests (p < 0.05). In a real dataset, SAN had the lowest SDM and Kolmogorov-Smirnov values for blood urea nitrogen, hematocrit, hemoglobin, and serum potassium, and the lowest SDM for serum creatinine (p < 0.05). Subgroup-adjusted normalization performed better than normalization using other methods. The SAN method is applicable in a DRN environment and should facilitate analysis of data integrated across DRN partners for retrospective observational studies. Copyright © 2015 John Wiley & Sons, Ltd.
... measurement for a result of this test. Normal value ranges may vary slightly among different laboratories. Some labs use different measurements or test different samples. Talk to your provider ...
Meija, Juris; Chartrand, Michelle M G
2018-01-01
Isotope delta measurements are normalized against international reference standards. Although multi-point normalization is becoming a standard practice, the existing uncertainty evaluation practices are either undocumented or are incomplete. For multi-point normalization, we present errors-in-variables regression models for explicit accounting of the measurement uncertainty of the international standards along with the uncertainty that is attributed to their assigned values. This manuscript presents framework to account for the uncertainty that arises due to a small number of replicate measurements and discusses multi-laboratory data reduction while accounting for inevitable correlations between the laboratories due to the use of identical reference materials for calibration. Both frequentist and Bayesian methods of uncertainty analysis are discussed.
Mathew, George; Kho, Abel; Dexter, Paul; Bloodworth, Nathaniel; Fantz, Corinne; Spell, Nathan; LaBorde, David V
2012-06-01
To develop a clinical decision support system activated at the time of discharge to reduce potentially inappropriate discharges from unidentified or unaddressed abnormal laboratory values. We identified 106 laboratory tests for possible inclusion in the discharge alert filter. We selected 7 labs as widely available, commonly obtained, and associated with high risk for potential morbidity or mortality within abnormal ranges. We identified trigger thresholds at levels that would capture significant laboratory abnormalities while avoiding excessive flag generation because of laboratory results that minimally deviate outside the normal reference range. We selected sodium (>155 or <125 mmol/L), potassium (<2.5 or >6 mEq/dL) phosphorous (<1.6 mg/dL), magnesium (<1.2 mg/dL), creatinine greater than 1.1 with a rise of 20% or more between the 2 most recent results, white blood cell count (>11,000 cells/mm with a rise of 20% or more between the 2 most recent results), and international normalized ratio greater than 4. A discharge alert filter that reliably and effectively identifies patients that may be discharged in unsafe situations because of unaddressed critical laboratory values can improve patient safety at discharge and potentially reduce the incidence of costly litigation. Further research is needed to validate whether the proposed discharge alert filter is effective at improving patient safety at discharge.
Laboratory diagnosis of von Willebrand's disease.
Rick, M E
1994-12-01
The diagnosis of von Willebrand's disease is becoming complex as more is understood about the disease. Clinical information and laboratory data are necessary for the diagnosis because of the overlap of normal and abnormal laboratory values. A complete evaluation including von Willebrand factor multimers, ristocetin-induced platelet aggregation, factor VIII activity level, and a template bleeding time is necessary to correctly classify the patient so that optimal treatment may be given.
Harvey, Stephen B; Krimer, Paula M; Correa, Maria T; Hanes, Martha A
2008-07-01
Plasma biochemical and hematologic values are important parameters for assessing animal health and experimental results. Although normal reference values for many rodent species have been published, there is a dearth of similar information for the genus Microtus. In addition, most studies use a mean and standard deviation to establish reference intervals, but doing so is not the recommendation of the Clinical and Laboratory Standards Institute (formerly the National Committee on Clinical Laboratory Standards) or the International Federation of Clinical Chemistry and Laboratory Medicine. The purpose of this study was to establish normal reference parameters for plasma biochemistry and hematology in mature pine voles (Microtus pinetorum) by using the nonparametric rank percentile method as recommended by the 2 laboratory medicine organizations mentioned. Samples of cardiac blood from a closed colony of pine voles were collected at euthanasia and evaluated under rodent settings on 2 automated hematology analyzers from 2 different manufacturers and on the same type of automated biochemistry analyzer. There were no sex-associated clinically significant differences between the sexes; younger animals had a lower hematocrit, higher mean corpuscular volume, and lower mean corpuscular hemoglobin concentration than did older animals. Only platelet counts differed when comparing hematologic values from different analyzers. Relative to rats and mice, pine voles have a lower mean corpuscular volume and higher red blood cell count, higher blood urea nitrogen, much higher alanine aminotransferase, and lower glucose and phosphorous concentrations. Hematology and plasma biochemical results obtained in this study are considered representative for healthy adult laboratory pine voles under similar environmental conditions.
Utility of common bile duct measurement in ED point of care ultrasound: A prospective study.
Lahham, Shadi; Becker, Brent A; Gari, Abdulatif; Bunch, Steven; Alvarado, Maili; Anderson, Craig L; Viquez, Eric; Spann, Sophia C; Fox, John C
2018-06-01
Measurement of the common bile duct (CBD) is considered a fundamental component of biliary point-of-care ultrasound (POCUS), but can be technically challenging. The primary objective of this study was to determine whether CBD diameter contributes to the diagnosis of complicated biliary pathology in emergency department (ED) patients with normal laboratory values and no abnormal biliary POCUS findings aside from cholelithiasis. We performed a prospective, observational study of adult ED patients undergoing POCUS of the right upper quadrant (RUQ) and serum laboratory studies for suspected biliary pathology. The primary outcome was complicated biliary pathology occurring in the setting of normal laboratory values and a POCUS demonstrating the absence of gallbladder wall thickening (GWT), pericholecystic fluid (PCF) and sonographic Murphy's sign (SMS). The association between CBD dilation and complicated biliary pathology was assessed using logistic regression to control for other factors, including laboratory findings, cholelithiasis and other sonographic abnormalities. A total of 158 patients were included in the study. 76 (48.1%) received non-biliary diagnoses and 82 (51.9%) were diagnosed with biliary pathology. Complicated biliary pathology was diagnosed in 39 patients. Sensitivity of CBD dilation for complicated biliary pathology was 23.7% and specificity was 77.9%. Of patients diagnosed with biliary pathology, none had isolated CBD dilatation. In the absence of abnormal laboratory values and GWT, PCF or SMS on POCUS, obtaining a CBD measurement is unlikely to contribute to the evaluation of this patient population. Copyright © 2017 Elsevier Inc. All rights reserved.
... above 35 U/mL is considered abnormal. Normal value ranges may vary slightly among different laboratories. Some ... 125 usually does not mean ovarian cancer is present. Most healthy women with an elevated CA-125 ...
Mann, F A; Boon, G D; Wagner-Mann, C C; Ruben, D S; Harrington, D P
1998-05-01
To determine whether pretreatment total and ionized blood magnesium concentrations were associated with outcome for dogs with parvoviral enteritis and whether ionized magnesium concentration was related to total magnesium concentration or other laboratory values. Prospective cohort study. 61 healthy dogs and 72 dogs with parvoviral enteritis. Total, ionized, and pH-normalized ionized magnesium concentrations, ionized and pH-normalized ionized calcium concentrations, pH, sodium and potassium concentrations, and Hct were measured prior to treatment. chi 2 Analyses were used to test for associations between outcome and age and between outcome and treatment with antiendotoxin antibody. Pearson's correlation coefficients were calculated to determine whether ionized magnesium concentration was linearly associated with other laboratory values. Total and ionized magnesium concentrations were not significantly different between healthy dogs and dogs with parvoviral enteritis or between dogs surviving and those not surviving parvoviral enteritis. The only laboratory value strongly correlated with ionized magnesium concentration was pH-normalized ionized magnesium concentration. Of the factors tested, none were significantly associated with outcome, except that dogs 16 weeks old or less treated with antiendotoxin antibody were significantly more likely to die than were dogs 16 weeks old or less that were not treated with antiendotoxin antibody. Total and ionized blood magnesium concentrations cannot be used to consistently predict outcome for dogs with parvoviral enteritis. Antiendotoxin antibody should be used with caution in dogs 16 weeks old or less.
Severe Coagulopathy after Ingestion of "Snake Wine".
Moon, Jeong Mi; Chun, Byeong Jo
2016-06-01
This report describes a patient who developed coagulopathy after ingesting snake wine, which is an alcoholic libation containing an entire venomous snake. A 68-year-old man was admitted to the hospital 19 h after ingesting snake wine. The laboratory features upon admission included unmeasurable activated partial thromboplastin (aPTT) values, prolonged prothrombin time (PT) values, increased fibrinogen levels, modestly elevated fibrin degradation product and D-dimer values, uncorrected aPTT and PT values after a mixing test, and normal levels of aspartate transaminase and alanine transaminase. No pesticides, warfarin, or superwarfarin in the patient's blood or urine were detected. His coagulation profile normalized on the 6(th) day after admission after antivenom treatment. He was discharged 10 days later without sequelae. WHY SHOULD AN EMERGENCY PHYSICIAN BE AWARE OF THIS?: The physician should be aware that ingesting snake wine may lead to systemic envenomation. As for coagulopathy, which may develop by ingesting snake venom, related laboratory findings may differ from the features observed after direct envenomation by snakebite. Copyright © 2015 Elsevier Inc. All rights reserved.
Coccidioides complement fixation
... antibodies are detected in the blood sample. Normal value ranges may vary slightly among different laboratories. Some labs use different measurements or test different samples. Talk to your health care provider about the meaning of your specific test results.
Harvey, Stephen B; Krimer, Paula M; Correa, Maria T; Hanes, Martha A
2008-01-01
Plasma biochemical and hematologic values are important parameters for assessing animal health and experimental results. Although normal reference values for many rodent species have been published, there is a dearth of similar information for the genus Microtus. In addition, most studies use a mean and standard deviation to establish reference intervals, but doing so is not the recommendation of the Clinical and Laboratory Standards Institute (formerly the National Committee on Clinical Laboratory Standards) or the International Federation of Clinical Chemistry and Laboratory Medicine. The purpose of this study was to establish normal reference parameters for plasma biochemistry and hematology in mature pine voles (Microtus pinetorum) by using the nonparametric rank percentile method as recommended by the 2 laboratory medicine organizations mentioned. Samples of cardiac blood from a closed colony of pine voles were collected at euthanasia and evaluated under rodent settings on 2 automated hematology analyzers from 2 different manufacturers and on the same type of automated biochemistry analyzer. There were no sex-associated clinically significant differences between the sexes; younger animals had a lower hematocrit, higher mean corpuscular volume, and lower mean corpuscular hemoglobin concentration than did older animals. Only platelet counts differed when comparing hematologic values from different analyzers. Relative to rats and mice, pine voles have a lower mean corpuscular volume and higher red blood cell count, higher blood urea nitrogen, much higher alanine aminotransferase, and lower glucose and phosphorous concentrations. Hematology and plasma biochemical results obtained in this study are considered representative for healthy adult laboratory pine voles under similar environmental conditions. PMID:18702449
Metrication of clinical laboratory data in SI units.
Lehmann, H P
1976-01-01
The development and general concepts of the Système International d'Unités (SI units) are discussed. The basic and derived quantities and units of the SI used for clinical laboratory data are reviewed. Ranges of normal values for a number of body fluid constituents are given in the units in current general use and in SI units, with corresponding conversion factors.
The narrow therapeutic window of glycated hemoglobin and assay variability.
Hosseini, S S; Bibler, I; Charles, M A
1999-12-01
Glycated hemoglobin is measured by a variety of assays, each of which has a unique normal level. Our purpose is to show that among the different assays available in the United States, using the same patient's blood sample, assay results may vary widely and may more or less easily achieve a glycated hemoglobin value within the normal range. The following assays were compared using the same patient's blood sample for each pair of assays: glycohemoglobin affinity assay (GHB Reader; Isolab, Akron, OH) versus gel electrophoresis assay (n = 76); Isolab versus ion capture assay (IMX; Abbott Laboratories, Irving, TX) (n = 57); monoclonal antibody assay (DCA2000; Bayer Diagnostics, Pittsburgh, PA) versus IMX (n = 100); and high-performance liquid chromatography (HPLC) assay (Bio-Rad Variant A1c; Bio-Rad Laboratories, Richmond, CA) versus IMX assay (n = 55). Our analyses indicate that a relative ranking can be established for the ease of achieving a normal glycated hemoglobin level. The ranking indicates that the most stringent or difficult assays for achieving a normal level are the Isolab and DCA2000 assays. The intermediate assays are the IMX and Bio-Rad Variant, and the easiest method for achieving a normal value is the gel electrophoresis assay. Our results indicate that various glycated hemoglobin assays vary widely and are associated with more or less difficulty for an individual patient to achieve a glycated hemoglobin level within the normal range. These results are especially significant with respect to (1) the clinically narrow therapeutic window of glycated hemoglobin values in type 1 diabetes to avoid rapidly advancing severe hypoglycemia rates and chronic microvascular complication rates, and (2) the glycated hemoglobin threshold for rapidly advancing macrovascular disease in both type 1 and type 2 patients.
Informative graphing of continuous safety variables relative to normal reference limits.
Breder, Christopher D
2018-05-16
Interpreting graphs of continuous safety variables can be complicated because differences in age, gender, and testing site methodologies data may give rise to multiple reference limits. Furthermore, data below the lower limit of normal are compressed relative to those points above the upper limit of normal. The objective of this study is to develop a graphing technique that addresses these issues and is visually intuitive. A mock dataset with multiple reference ranges is initially used to develop the graphing technique. Formulas are developed for conditions where data are above the upper limit of normal, normal, below the lower limit of normal, and below the lower limit of normal when the data value equals zero. After the formulae are developed, an anonymized dataset from an actual set of trials for an approved drug is evaluated comparing the technique developed in this study to standard graphical methods. Formulas are derived for the novel graphing method based on multiples of the normal limits. The formula for values scaled between the upper and lower limits of normal is a novel application of a readily available scaling formula. The formula for the lower limit of normal is novel and addresses the issue of this value potentially being indeterminate when the result to be scaled as a multiple is zero. The formulae and graphing method described in this study provides a visually intuitive method to graph continuous safety data including laboratory values, vital sign data.
Rheumatoid-like arthritis associated with a colonic carcinoma.
Simon, R D; Ford, L E
1980-05-01
A 76-year-old woman with rapidly progressive athritis associated with a rising rheumatoid factor, acute joint effusion, and fever had remission of her symptoms and return of her laboratory values to normal following removal of a colonic carcinoma.
Liu, Jien-Wei; Lee, Ing-Kit; Wang, Lin; Chen, Rong-Fu; Yang, Kuender D.
2013-01-01
Alertness to dengue and making a timely diagnosis is extremely important in the treatment of dengue and containment of dengue epidemics. We evaluated the complementary role of clinical-practice-based laboratory data in facilitating suspicion/diagnosis of dengue. One hundred overall dengue (57 dengue fever [DF] and 43 dengue hemorrhagic fever [DHF]) cases and another 100 nondengue cases (78 viral infections other than dengue, 6 bacterial sepsis, and 16 miscellaneous diseases) were analyzed. We separately compared individual laboratory variables (platelet count [PC] , prothrombin time [PT], activated partial thromboplastin time [APTT], alanine aminotransferase [ALT], and aspartate aminotransferase [AST]) and varied combined variables of DF and/or DHF cases with the corresponding ones of nondengue cases. The sensitivity, specificity, accuracy, positive predictive value (PPV), and negative predictive value (NPV) in the diagnosis of DF and/or DHF were measured based on these laboratory variables. While trade-off between sensitivity and specificity, and/or suboptimal PPV/NPV was found at measurements using these variables, prolonged APTT + normal PT + PC < 100 × 109 cells/L had a favorable sensitivity, specificity, PPV, and NPV in diagnosis of DF and/or DHF. In conclusion, these data suggested that prolonged APTT + normal PT + PC < 100 × 109 cells/L is useful in evaluating the likelihood of DF and/or DHF. PMID:24455678
Lovell, David P; Fellows, Mick; Marchetti, Francesco; Christiansen, Joan; Elhajouji, Azeddine; Hashimoto, Kiyohiro; Kasamoto, Sawako; Li, Yan; Masayasu, Ozaki; Moore, Martha M; Schuler, Maik; Smith, Robert; Stankowski, Leon F; Tanaka, Jin; Tanir, Jennifer Y; Thybaud, Veronique; Van Goethem, Freddy; Whitwell, James
2018-01-01
The recent revisions of the Organisation for Economic Co-operation and Development (OECD) genetic toxicology test guidelines emphasize the importance of historical negative controls both for data quality and interpretation. The goal of a HESI Genetic Toxicology Technical Committee (GTTC) workgroup was to collect data from participating laboratories and to conduct a statistical analysis to understand and publish the range of values that are normally seen in experienced laboratories using TK6 cells to conduct the in vitro micronucleus assay. Data from negative control samples from in vitro micronucleus assays using TK6 cells from 13 laboratories were collected using a standard collection form. Although in some cases statistically significant differences can be seen within laboratories for different test conditions, they were very small. The mean incidence of micronucleated cells/1000 cells ranged from 3.2/1000 to 13.8/1000. These almost four-fold differences in micronucleus levels cannot be explained by differences in scoring method, presence or absence of exogenous metabolic activation (S9), length of treatment, presence or absence of cytochalasin B or different solvents used as vehicles. The range of means from the four laboratories using flow cytometry methods (3.7-fold: 3.5-12.9 micronucleated cells/1000 cells) was similar to that from the nine laboratories using other scoring methods (4.3-fold: 3.2-13.8 micronucleated cells/1000 cells). No laboratory could be identified as an outlier or as showing unacceptably high variability. Quality Control (QC) methods applied to analyse the intra-laboratory variability showed that there was evidence of inter-experimental variability greater than would be expected by chance (i.e. over-dispersion). However, in general, this was low. This study demonstrates the value of QC methods in helping to analyse the reproducibility of results, building up a 'normal' range of values, and as an aid to identify variability within a laboratory in order to implement processes to maintain and improve uniformity. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.
Average of delta: a new quality control tool for clinical laboratories.
Jones, Graham R D
2016-01-01
Average of normals is a tool used to control assay performance using the average of a series of results from patients' samples. Delta checking is a process of identifying errors in individual patient results by reviewing the difference from previous results of the same patient. This paper introduces a novel alternate approach, average of delta, which combines these concepts to use the average of a number of sequential delta values to identify changes in assay performance. Models for average of delta and average of normals were developed in a spreadsheet application. The model assessed the expected scatter of average of delta and average of normals functions and the effect of assay bias for different values of analytical imprecision and within- and between-subject biological variation and the number of samples included in the calculations. The final assessment was the number of patients' samples required to identify an added bias with 90% certainty. The model demonstrated that with larger numbers of delta values, the average of delta function was tighter (lower coefficient of variation). The optimal number of samples for bias detection with average of delta was likely to be between 5 and 20 for most settings and that average of delta outperformed average of normals when the within-subject biological variation was small relative to the between-subject variation. Average of delta provides a possible additional assay quality control tool which theoretical modelling predicts may be more valuable than average of normals for analytes where the group biological variation is wide compared with within-subject variation and where there is a high rate of repeat testing in the laboratory patient population. © The Author(s) 2015.
Giesbrandt, Kirk J; Bulatao, Ilynn G; Keaveny, Andrew P; Nguyen, Justin H; Paz-Fumagalli, Ricardo; Taner, C Burcin
2015-11-01
The purpose of this study was to define the cholangiographic patterns of ischemic cholangiopathy and clinically silent nonanastomotic biliary strictures in donation-after-cardiac-death (DCD) liver grafts in a large single-institution series. We also examined the correlation of the radiologic findings with laboratory data and clinical outcomes. Data were collected for all DCD liver transplants at one institution from December 1998 to December 2011. Posttransplant cholangiograms were obtained during postoperative weeks 1 and 3 and when clinically indicated. Intrahepatic biliary strictures were classified by anatomic distribution and chronologic development. Radiologic findings were correlated with laboratory data and with 1-, 3-, and 5-year graft and patient survival rates. A total of 231 patients received DCD grafts. Cholangiograms were available for 184 of these patients. Postoperative cholangiographic findings were correlated with clinical data and divided into the following three groups: A, normal cholangiographic findings with normal laboratory values; B, radiologic abnormalities and cholangiopathy according to laboratory values; and C, radiologic abnormalities without laboratory abnormalities. Group B had four distinct abnormal cholangiographic patterns that were predictive of graft survival. Group C had mild nonprogressive multifocal stenoses and decreased graft and patient survival rates, although cholangiopathy was not detected in these patients according to laboratory data. Patterns and severity of nonanastomotic biliary abnormalities in DCD liver transplants can be defined radiologically and correlate with clinical outcomes. Postoperative cholangiography can depict the mild biliary abnormalities that occur in a subclinical manner yet cause a marked decrease in graft and patient survival rates in DCD liver transplants.
Namkoong, Sun; Hong, Seung Phil; Kim, Myung Hwa; Park, Byung Cheol
2013-02-01
Nowadays, although its clinical value remains controversial institutions utilize hair mineral analysis. Arguments about the reliability of hair mineral analysis persist, and there have been evaluations of commercial laboratories performing hair mineral analysis. The objective of this study was to assess the reliability of intra-laboratory and inter-laboratory data at three commercial laboratories conducting hair mineral analysis, compared to serum mineral analysis. Two divided hair samples taken from near the scalp were submitted for analysis at the same time, to all laboratories, from one healthy volunteer. Each laboratory sent a report consisting of quantitative results and their interpretation of health implications. Differences among intra-laboratory and interlaboratory data were analyzed using SPSS version 12.0 (SPSS Inc., USA). All the laboratories used identical methods for quantitative analysis, and they generated consistent numerical results according to Friedman analysis of variance. However, the normal reference ranges of each laboratory varied. As such, each laboratory interpreted the patient's health differently. On intra-laboratory data, Wilcoxon analysis suggested they generated relatively coherent data, but laboratory B could not in one element, so its reliability was doubtful. In comparison with the blood test, laboratory C generated identical results, but not laboratory A and B. Hair mineral analysis has its limitations, considering the reliability of inter and intra laboratory analysis comparing with blood analysis. As such, clinicians should be cautious when applying hair mineral analysis as an ancillary tool. Each laboratory included in this study requires continuous refinement from now on for inducing standardized normal reference levels.
Lack of correlation between serum soluble Fas/APO-1 levels and autoimmune disease.
Goel, N; Ulrich, D T; St Clair, E W; Fleming, J A; Lynch, D H; Seldin, M F
1995-12-01
To determine whether elevated soluble Fas/APO-1 (sFas/APO-1) levels are associated with either autoimmune disease or evidence of flares in autoimmune disease. Thirty-seven serum samples were retrospectively obtained from normal controls and patients with laboratory evidence of autoimmune disease activity. These samples were assayed for sFas/APO-1 levels by an enzyme-linked immunosorbent assay, and hospital medical records were retrospectively reviewed for clinical and laboratory characteristics of the patients. Soluble Fas/APO-1 levels did not correlate with clinical diagnoses or laboratory abnormalities. The mean and range of sFas/APO-1 levels were similar in systemic lupus erythematosus patients (including those with active disease), patients with other autoimmune diseases, and normal controls. These data strongly suggest that measurement of sFas/APO-1 levels is unlikely to hold clinical value or play a role in the pathogenesis of autoimmune disease.
[Steinert disease: abnormal onset or "casual" diagnosis?].
Pempinello, R; Iannece, M D; Di Pierro, M
2001-01-01
The most frequent myopathy is "Steinert's disease" (also called myotonic dystrophy). We present a case of particular interest due to the way diagnosis was made. A 20-year-old male was transferred to our Department from another Hospital with a diagnosis of "acute liver disease". He presented with fever (39 degrees C), tetrahyposthenia, dehydration and spatial-temporal disorientation. The most apparent laboratory data was a significant increase in serum levels of creatine phosphokinase (196,260 IU/L; normal values < 50 IU/L). After therapy based on parenteral nutrition and steroids, our patient improved progressively, with normalization of laboratory values. Muscle biopsy and electromyography yielded a diagnosis of Steinert's disease, and the patient's mother was found to be the carrier of a myotonine-kinase gene mutation. In this case, the onset of what appeared to be an influenza-A virus infection (the only positive data observed in the serological analysis) permitted the diagnosis of a hereditary myopathy that had remained asymptomatic up to that time.
Variables affecting the quantitation of CD22 in neoplastic B cells.
Jasper, Gregory A; Arun, Indu; Venzon, David; Kreitman, Robert J; Wayne, Alan S; Yuan, Constance M; Marti, Gerald E; Stetler-Stevenson, Maryalice
2011-03-01
Quantitative flow cytometry (QFCM) is being applied in the clinical flow cytometry laboratory for diagnosis, prognosis, and assessment of patients receiving antibody-based therapy. ABC values and the effect of technical variables on CD22 quantitation in acute lymphoblastic leukemia (ALL), chronic lymphocytic leukemia (CLL), mantle cell lymphoma (MCL), follicular lymphoma (FCL), hairy cell leukemia (HCL) and normal B cells were studied. The QuantiBrite System® was used to determine the level of CD22 expression (mean antibody bound per cell, ABC) by malignant and normal B cells. The intra-assay variability, number of cells required for precision, effect of delayed processing as well as shipment of peripheral blood specimens (delayed processing and exposure to noncontrolled environments), and the effect of paraformaldehyde fixation on assay results were studied. The QuantiBRITE method of measuring CD22 ABC is precise (median CV 1.6%, 95% confidence interval, 1.2-2.3%) but a threshold of 250 malignant cells is required for reliable CD22 ABC values. Delayed processing and overnight shipment of specimens resulted in significantly different ABC values whereas fixation for up to 12 h had no significant effect. ABC measurements determined that CD22 expression is lower than normal in ALL, CLL, FCL, and MCL but higher than normal in HCL. CD22 expression was atypical in the hematolymphoid malignancies studied and may have diagnostic utility. Technical variables such as cell number analyzed and delayed processing or overnight shipment of specimens impact significantly on the measurement of antigen expression by QFCM in the clinical laboratory. Published 2010 Wiley-Liss, Inc.
1974-08-31
morphology 10I I Platelet morphology Estimating platelet numbers Normal values Use of oil immersion microscope Use of differential cell tabulator i 1...by use of impregnated discs on the surface of media (Mueller Hinton) seeded with test organism, or by bacteria or serum tube dilution methods...result Physiologic incompatibilities of test results Use and operation of refractometer , urinometer and centrifuge microscope Recognition of
Coplen, Tyler B.; Wassenaar, Leonard I
2015-01-01
Although laser absorption spectrometry (LAS) instrumentation is easy to use, its incorporation into laboratory operations is not easy, owing to extensive offline manipulation of comma-separated-values files for outlier detection, between-sample memory correction, nonlinearity (δ-variation with water amount) correction, drift correction, normalization to VSMOW-SLAP scales, and difficulty in performing long-term QA/QC audits. METHODS: A Microsoft Access relational-database application, LIMS (Laboratory Information Management System) for Lasers 2015, was developed. It automates LAS data corrections and manages clients, projects, samples, instrument-sample lists, and triple-isotope (δ(17) O, δ(18) O, and δ(2) H values) instrumental data for liquid-water samples. It enables users to (1) graphically evaluate sample injections for variable water yields and high isotope-delta variance; (2) correct for between-sample carryover, instrumental drift, and δ nonlinearity; and (3) normalize final results to VSMOW-SLAP scales. RESULTS: Cost-free LIMS for Lasers 2015 enables users to obtain improved δ(17) O, δ(18) O, and δ(2) H values with liquid-water LAS instruments, even those with under-performing syringes. For example, LAS δ(2) HVSMOW measurements of USGS50 Lake Kyoga (Uganda) water using an under-performing syringe having ±10 % variation in water concentration gave +31.7 ± 1.6 ‰ (2-σ standard deviation), compared with the reference value of +32.8 ± 0.4 ‰, after correction for variation in δ value with water concentration, between-sample memory, and normalization to the VSMOW-SLAP scale. CONCLUSIONS: LIMS for Lasers 2015 enables users to create systematic, well-founded instrument templates, import δ(2) H, δ(17) O, and δ(18) O results, evaluate performance with automatic graphical plots, correct for δ nonlinearity due to variable water concentration, correct for between-sample memory, adjust for drift, perform VSMOW-SLAP normalization, and perform long-term QA/QC audits easily.
Ridout, Kathryn K; Kole, Jonathan; Fitzgerald, Kelly L; Ridout, Samuel J; Donaldson, Abigail A; Alverson, Brian
2016-07-01
This study investigates how the clinical practice guideline-recommended laboratory monitoring for refeeding syndrome impacts management and outcomes of adolescents with eating disorders hospitalized for acute medical stabilization and examines the value of laboratory monitoring (defined as the patient health outcomes achieved per dollar spent). A retrospective chart review of medical admissions in a children's hospital between October 2010 and February 2014 was performed. Encounters were identified using International Classification of Diseases, Ninth Revision codes of eating disorders as primary or secondary diagnoses. Exclusion criteria included systemic diseases associated with significant electrolyte abnormalities. Chart abstraction was performed using a predetermined form. Costs were estimated by converting hospital-fixed Medicaid charges using a statewide cost-to-charge ratio. Of the 196 patient encounters, there were no cases of refeeding syndrome. A total of 3,960 key recommended laboratories were obtained; 1.9% were below normal range and .05% were critical values. Of these, .28% resulted in supplementation; none were associated with a change in inpatient management. Total laboratory costs were $269,250.85; the calculated health care value of this monitoring is 1.04 × 10(-8) differential outcomes per dollar spent. This study provides evidence to suggest that daily laboratory monitoring for refeeding syndrome is a poor health care value in the management of adolescents hospitalized for acute medical stabilization with eating disorders. This initial analysis suggests that starting at a relatively low caloric level and advancing nutrition slowly may negate the need for daily laboratory assessment, which may have important implications for current guidelines. Copyright © 2016 Society for Adolescent Health and Medicine. Published by Elsevier Inc. All rights reserved.
Utility of Reference Change Values for Delta Check Limits.
Ko, Dae-Hyun; Park, Hae-Il; Hyun, Jungwon; Kim, Hyun Soo; Park, Min-Jeong; Shin, Dong Hoon
2017-10-01
To assess the utility of reference change values (RCVs) as delta check limits. A total of 1,650,518 paired results for 23 general chemistry test results from June 1, 2014, to October 31, 2016, were analyzed. The RCVs for each analyte were calculated from the analytical imprecision and within-subject biological variation. The percent differences between two consecutive results in one patient were categorized into one of four groups: outpatients, inpatients, emergency care, and general health care. For each, 2.5th and 97.5th percentile values were computed and compared with their RCVs. The distributions were assessed for normality using the Kolmogorov-Smirnov test. Most of the estimated limits were larger than the corresponding RCVs and, furthermore, with notable differences across the groups. Patients in the emergency care group usually demonstrated larger delta percent values than those in the other groups. None of the distributions of the percent differences passed tests of normality when subjected to Kolmogorov-Smirnov analysis. Comparison of estimated RCVs and real-world patient data revealed the pitfalls of applying RCVs in clinical laboratories. Laboratory managers should be aware of the limitations of RCVs and exercise caution when using them. © American Society for Clinical Pathology, 2017. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com
42 CFR 493.1253 - Standard: Establishment and verification of performance specifications.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 42 Public Health 5 2010-10-01 2010-10-01 false Standard: Establishment and verification of..., DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) STANDARDS AND CERTIFICATION LABORATORY REQUIREMENTS... of test results for the test system. (vi) Reference intervals (normal values). (vii) Any other...
[Blood lipids and adaptation to stress as risk factors for stroke prevention].
Anders, I; Esterbauer, E; Fink, A; Ladurner, G; Huemer, M; Wranek, U
2000-01-01
Do stroke prevention patients with increased blood-fat-protein compounds (total cholesterol, HDL- and LDL cholesterol and triglyceride) have a different method of coping than patients with normal blood fat? 1159 stroke prevention patients participated in the following stroke risk investigations at this hospital: biographical and risk factor-orientated anamnesis, a neurological status investigation, a laboratory investigation, a sonographic investigation and a psychological investigation. The differences in the coping strategies of those patients with normal and those with higher blood-fat-protein compounds were investigated. Patients with higher total cholesterol showed significantly higher values in the avoidance of stress situations (sig. 0.041) and a stronger tendency towards escapist behaviour (sig. 0.05). Patients with normal HDL cholesterol values indicated a tendency (sig. 0.07) to higher values in positive self-instruction in comparison to patients with reduced HDL cholesterol values. Those prevention patients with higher LDL values showed a tendency (sig. 0.08) to higher values in the intake of narcotic substances (nicotine, alcohol, tranquillisers, pharmaceutical agents). Patients with increased triglyceride indicated significantly higher values in coping by compensation (eating, shopping, reward behaviour, watching TV; sig. 0.037) and the intake of narcotic substances (sig. 0.044). Prevention patients with higher total cholesterol, LDL/HDL, or triglyceride values showed significantly different coping strategies in comparison to those patients with normal values. Increased avoidance and escapism behaviour and also compensation and the abuse of narcotic substances could be seen in connection with an increase in the risk of a stroke. In contrast, a constructive coping strategy such as positive self-instruction could reduce the risk of a stroke, which goes along with normal HDL cholesterol.
USDA-ARS?s Scientific Manuscript database
A series of tests were conducted to determine residual efficacy of pyrethrin+methoprene aerosol to manage larvae of selected stored product insects. Efficacy was assessed through emergence of morphologically-normal adults and through a quantitative developmental index with values ranging from 1, for...
Meijer, Piet; Kynde, Karin; van den Besselaar, Antonius M H P; Van Blerk, Marjan; Woods, Timothy A L
2018-04-12
This study was designed to obtain an overview of the analytical quality of the prothrombin time, reported as international normalized ratio (INR) and to assess the variation of INR results between European laboratories, the difference between Quick-type and Owren-type methods and the effect of using local INR calibration or not. In addition, we assessed the variation in INR results obtained for a single donation in comparison with a pool of several plasmas. A set of four different lyophilized plasma samples were distributed via national EQA organizations to participating laboratories for INR measurement. Between-laboratory variation was lower in the Owren group than in the Quick group (on average: 6.7% vs. 8.1%, respectively). Differences in the mean INR value between the Owren and Quick group were relatively small (<0.20 INR). Between-laboratory variation was lower after local INR calibration (CV: 6.7% vs. 8.6%). For laboratories performing local calibration, the between-laboratory variation was quite similar for the Owren and Quick group (on average: 6.5% and 6.7%, respectively). Clinically significant differences in INR results (difference in INR>0.5) were observed between different reagents. No systematic significant differences in the between-laboratory variation for a single-plasma sample and a pooled plasma sample were observed. The comparability for laboratories using local calibration of their thromboplastin reagent is better than for laboratories not performing local calibration. Implementing local calibration is strongly recommended for the measurement of INR.
The normalization heuristic: an untested hypothesis that may misguide medical decisions.
Aberegg, Scott K; O'Brien, James M
2009-06-01
Medical practice is increasingly informed by the evidence from randomized controlled trials. When such evidence is not available, clinical hypotheses based on pathophysiological reasoning and common sense guide clinical decision making. One commonly utilized general clinical hypothesis is the assumption that normalizing abnormal laboratory values and physiological parameters will lead to improved patient outcomes. We refer to the general use of this clinical hypothesis to guide medical therapeutics as the "normalization heuristic". In this paper, we operationally define this heuristic and discuss its limitations as a rule of thumb for clinical decision making. We review historical and contemporaneous examples of normalization practices as empirical evidence for the normalization heuristic and to highlight its frailty as a guide for clinical decision making.
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1998-11-06
In support of the Weldon Spring Site Remedial Action Project Federal Facilities Agreement, a copy of the Quarterly Environmental Data Summary (QEDS) for the third quarter of 1998 is enclosed. The data presented in this letter and attachment constitute the QEDS. The data, except for air monitoring data and site KPA generated data (uranium analyses), were received from the contract laboratories, verified by the Weldon Spring Site verification group, and merged into the database during the third quarter of 1998. Air monitoring data presented are the most recent complete sets of quarterly data. Significant data, defined as data values thatmore » have exceeded defined above normal Level 2 values, are discussed in this letter for Environmental Monitoring Plan (EMP) generated data only. Above normal Level 2 values are based, in ES and H procedures, on historical high values, DOE Derived Concentration Guides (DCGs), NPDES limits, and other guidelines. The procedures also establish actions to be taken in the event that above normal data occur.« less
Difference in normal values of median nerve cross-sectional area between Dutch and Indian subjects.
Burg, Ellen Walhout-van; Bathala, Lokesh; Visser, Leo H
2014-07-01
Ultrasound (US) measurement of the median nerve cross-sectional area (CSA) at the wrist is a useful diagnostic test for carpal tunnel syndrome (CTS). We compared median nerve normal values between samples of Indian and Dutch populations. The median nerve was examined by US at the wrist in 100 healthy volunteers in India and 137 volunteers in The Netherlands using the same protocol. Median nerve CSA at the wrist (7.0 ± 1.1 mm(2)) in the Indian cohort was lower in comparison to the Dutch cohort (8.3 ± 1.9 mm(2) ; P < 0.05). This difference was still present after controlling for age, height, and weight (P = 0.001). CSA normal values for the median nerve were different between the examined population samples even after correcting for age, height, and weight. This enforces the idea that laboratories around the world should obtain their own normative data. Copyright © 2013 Wiley Periodicals, Inc.
Euthyroid ''thyroxine toxicosis''
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mankikar, G.D.; Clark, A.N.
A survey was made of thyroid function tests on 1,153 patients screened for thyroid disease during a two-year period in a Geriatric Department; 13 percent of the test results fell outside the normal range. Of 88 patients who showed above-normal results, only 12 presented with clinical features of thyrotoxicosis. In 37 patients, the biochemical findings indicated euthyroid ''thyroxine toxicosis''; high values were found for serum thyroxine (T4) and the free thyroxine index (FT4I) but there were no clinical signs or symptoms of thyrotoxicosis; the values reverted to normal within one to three weeks. This pattern was seen also in 7more » examples of T4-treated hypothyroidism. (Overall, the test findings indicated 61 cases of hypothyroidism.) The significance of this transient increase in T4 and FT4I values is discussed. The false positive results suggest that, when laboratory findings are not compatible with the clinical signs, the thyroid function tests should be repeated after another two weeks.« less
Implications of false positive serology of Toxoplasma gondii in a pre-transplant patient.
Beal, Stacy; Racsa, Lori; Alatoom, Adnan
2014-01-01
A 21-year-old white male with cystic fibrosis. Pre-transplant workup in preparation for bilateral lung transplant. Cystic fibrosis diagnosed at age 3, onset of insulin-dependent diabetes around age 20, and multiple hospitalizations for pulmonary and gastrointestinal complications. FAMILY AND SOCIAL HISTORY: The patient lives with his father and stepmother, has a pet bearded dragon, and has multiple tattoos and piercings. His stepmother has a cat, but he does not clean the litter box. The pre-transplant workup included several tests for infectious diseases, tests of organ function, radiology studies, and markers of malignancy. The only significant finding was a positive Toxoplasma gondii (T. gondii) IgM titer (> or = 1:40) (reference values for IgM: negative; < 1:40, positive; > or = 1:40) and IgG (1:2048) (reference values for IgG: negative; < 1:16, equivocal; > or = 1:16 - < 1:256, positive; > or = 1:256). Testing was done by indirect immunofluorescence assay (IFA) in April 2012 in our hospital laboratory. The patient was treated with sulfadiazine, leucovorin, and pyrimethamine. Three months later (July), he returned for follow-up testing. Real-time polymerase chain reaction (PCR) for T. gondii DNA performed by a reference laboratory was negative. One month later (August), Toxoplasma serology was performed by enzyme-linked immunosorbent assay (ELISA) by a different reference laboratory and showed an elevated IgM of 0.95 IU/mL (reference values: negative; < 0.55 IU/mL, equivocal; > or = 0.55- < 0.65 IU/mL, positive; > or = 0.65 IU/mL) and a normal level of IgG (< 4 IU/mL). At this time, PCR was repeated and was negative. An additional month later (September), the patient's serology studies were performed at a third reference laboratory and showed an elevated IgM of 1.32 IU/mL (reference values: negative; 0.89, equivocal; 0.90 - 1.09, positive; > 1.10) and a normal IgG.
Creatine and guanidinoacetate reference values in a French population.
Joncquel-Chevalier Curt, Marie; Cheillan, David; Briand, Gilbert; Salomons, Gajja S; Mention-Mulliez, Karine; Dobbelaere, Dries; Cuisset, Jean-Marie; Lion-François, Laurence; Des Portes, Vincent; Chabli, Allel; Valayannopoulos, Vassili; Benoist, Jean-François; Pinard, Jean-Marc; Simard, Gilles; Douay, Olivier; Deiva, Kumaran; Tardieu, Marc; Afenjar, Alexandra; Héron, Delphine; Rivier, François; Chabrol, Brigitte; Prieur, Fabienne; Cartault, François; Pitelet, Gaëlle; Goldenberg, Alice; Bekri, Soumeya; Gerard, Marion; Delorme, Richard; Porchet, Nicole; Vianey-Saban, Christine; Vamecq, Joseph
2013-11-01
Creatine and guanidinoacetate are biomarkers of creatine metabolism. Their assays in body fluids may be used for detecting patients with primary creatine deficiency disorders (PCDD), a class of inherited diseases. Their laboratory values in blood and urine may vary with age, requiring that reference normal values are given within the age range. Despite the long known role of creatine for muscle physiology, muscle signs are not necessarily the major complaint expressed by PCDD patients. These disorders drastically affect brain function inducing, in patients, intellectual disability, autistic behavior and other neurological signs (delays in speech and language, epilepsy, ataxia, dystonia and choreoathetosis), being a common feature the drop in brain creatine content. For this reason, screening of PCDD patients has been repeatedly carried out in populations with neurological signs. This report is aimed at providing reference laboratory values and related age ranges found for a large scale population of patients with neurological signs (more than 6 thousand patients) previously serving as a background population for screening French patients with PCDD. These reference laboratory values and age ranges compare rather favorably with literature values for healthy populations. Some differences are also observed, and female participants are discriminated from male participants as regards to urine but not blood values including creatine on creatinine ratio and guanidinoacetate on creatinine ratio values. Such gender differences were previously observed in healthy populations; they might be explained by literature differential effects of testosterone and estrogen in adolescents and adults, and by estrogen effects in prepubertal age on SLC6A8 function. Finally, though they were acquired on a population with neurological signs, the present data might reasonably serve as reference laboratory values in any future medical study exploring abnormalities of creatine metabolism and transport. © 2013 Elsevier Inc. All rights reserved.
Howanitz, Peter J; Darcy, Theresa P; Meier, Frederick A; Bashleben, Christine P
2015-09-01
The anticoagulant warfarin has been identified as the second most frequent drug responsible for serious, disabling, and fatal adverse drug events in the United States, and its effect on blood coagulation is monitored by the laboratory test called international normalized ratio (INR). To determine the presence of INR policies and procedures, INR practices, and completeness and timeliness of reporting critical INR results in participants' clinical laboratories. Participants reviewed their INR policies and procedure requirements, identified their practices by using a questionnaire, and studied completeness of documentation and timeliness of reporting critical value INR results for outpatients and emergency department patients. In 98 participating institutions, the 5 required policies and procedures were in place in 93% to 99% of clinical laboratories. Fifteen options for the allowable variations among duplicate results from different analyzers, 12 different timeliness goals for reporting critical values, and 18 unique critical value limits were used by participants. All required documentation elements were present in 94.8% of 192 reviewed INR validation reports. Critical value INR results were reported within the time frame established by the laboratory for 93.4% of 2604 results, but 1.0% of results were not reported. Although the median laboratories successfully communicated all critical results within their established time frames and had all the required validation elements based in their 2 most recent INR calculations, those participants at the lowest 10th percentile were successful in 80.0% and 85.7% of these requirements, respectively. Significant opportunities exist for adherence to INR procedural requirements and for practice patterns and timeliness goals for INR critical results' reporting.
Llovet, Maria Isabel; Biosca, Carmen; Martínez-Iribarren, Alicia; Blanco, Aurora; Busquets, Glòria; Castro, María José; Llopis, Maria Antonia; Montesinos, Mercè; Minchinela, Joana; Perich, Carme; Prieto, Judith; Ruiz, Rosa; Serrat, Núria; Simón, Margarita; Trejo, Alex; Monguet, Josep Maria; López-Pablo, Carlos; Ibarz, Mercè
2018-02-23
There is no consensus in the literature about what analytes or values should be informed as critical results and how they should be communicated. The main aim of this project is to establish consensual standards of critical results for the laboratories participating in the study. Among the project's secondary objectives, establishing consensual procedures for communication can be highlighted. Consensus was reached among all participating laboratories establishing the basis for the construction of the initial model put forward for consensus in conjunction with the clinicians. A real-time Delphi, methodology "health consensus" (HC), with motivating and participative questions was applied. The physician was expected to choose a numeric value within a scale designed for each analyte. The medians of critical results obtained represent the consensus on critical results for outpatient and inpatient care. Both in primary care and in hospital care a high degree of consensus was observed for critical values proposed in the analysis of creatinine, digoxin, phosphorus, glucose, international normalized ratio (INR), leukocytes, magnesium, neutrophils, chloride, sodium, calcium and lithium. For the rest of critical results the degree of consensus obtained was "medium high". The results obtained showed that in 72% of cases the consensual critical value coincided with the medians initially proposed by the laboratories. The real-time Delphi has allowed obtaining consensual standards for communication of critical results among the laboratories participating in the study, which can serve as a basis for other organizations.
Kenney, Kimbra; Landau, Mark E; Gonzalez, Rodney S; Hundertmark, Julie; O'Brien, Karen; Campbell, William W
2012-03-01
In this investigation we assessed the spectrum of creatine kinase (CK) responses in military recruits undergoing basic training. Musculoskeletal examination data, questionnaire findings, and CK levels were obtained from 499 recruits at days 0, 3, 7, and 14 of training. Correlations of CK with ethnicity, age, body mass index, exercise, muscle pain, and climate were obtained. None of the subjects developed clinical exertional rhabdomyolysis (ER). The mean/median serum CK values were 223/157, 734/478, 1226/567, and 667/486 IU/L at days 0, 3, 7, and 14, respectively, with a wide overall range (34-35,056 IU/L). African-American subjects had higher mean CK levels. CK elevations and muscle pain are common during basic training. Widely accepted laboratory diagnostic values for ER are routinely exceeded in this military recruits, suggesting that CK levels >50 times the upper limit of normal are more specific. The findings support using CK as a marker for ER. Normal laboratory reference ranges for CK should be published by ethnicity. Copyright © 2011 Wiley Periodicals, Inc.
Severity of Illness Scores May Misclassify Critically Ill Obese Patients.
Deliberato, Rodrigo Octávio; Ko, Stephanie; Komorowski, Matthieu; Armengol de La Hoz, M A; Frushicheva, Maria P; Raffa, Jesse D; Johnson, Alistair E W; Celi, Leo Anthony; Stone, David J
2018-03-01
Severity of illness scores rest on the assumption that patients have normal physiologic values at baseline and that patients with similar severity of illness scores have the same degree of deviation from their usual state. Prior studies have reported differences in baseline physiology, including laboratory markers, between obese and normal weight individuals, but these differences have not been analyzed in the ICU. We compared deviation from baseline of pertinent ICU laboratory test results between obese and normal weight patients, adjusted for the severity of illness. Retrospective cohort study in a large ICU database. Tertiary teaching hospital. Obese and normal weight patients who had laboratory results documented between 3 days and 1 year prior to hospital admission. None. Seven hundred sixty-nine normal weight patients were compared with 1,258 obese patients. After adjusting for the severity of illness score, age, comorbidity index, baseline laboratory result, and ICU type, the following deviations were found to be statistically significant: WBC 0.80 (95% CI, 0.27-1.33) × 10/L; p = 0.003; log (blood urea nitrogen) 0.01 (95% CI, 0.00-0.02); p = 0.014; log (creatinine) 0.03 (95% CI, 0.02-0.05), p < 0.001; with all deviations higher in obese patients. A logistic regression analysis suggested that after adjusting for age and severity of illness at least one of these deviations had a statistically significant effect on hospital mortality (p = 0.009). Among patients with the same severity of illness score, we detected clinically small but significant deviations in WBC, creatinine, and blood urea nitrogen from baseline in obese compared with normal weight patients. These small deviations are likely to be increasingly important as bigger data are analyzed in increasingly precise ways. Recognition of the extent to which all critically ill patients may deviate from their own baseline may improve the objectivity, precision, and generalizability of ICU mortality prediction and severity adjustment models.
Anorectal physiology measurements are of no value in clinical practice. True or false?
Carty, N. J.; Moran, B.; Johnson, C. D.
1994-01-01
This article examines whether there is any clinical value in anorectal physiology measurements. The function of the human rectum is poorly understood and the factors which affect function of the anal sphincters are complex. Several laboratories have reported results of anorectal physiology measurements, but there is extensive variation between normal values in different laboratories. It is argued that anorectal physiology measurements fail to meet the criteria of a useful clinical test: 1. It is not widely available to clinicians; 2. It is not possible to establish a reproducible normal range; 3. Abnormal measurements do not correlate with disease entities or explain symptoms; 4. The results are often unhelpful in diagnosis and management; 5. Clinical outcome after intervention does not correlate with alteration in the measurements obtained. On the other hand it can be argued that anorectal physiology measurements do provide information that assists in the management of conditions such as constipation, anismus, Hirschsprung's disease, faecal incontinence and tenesmus. Management based on biofeedback modification of physiological responses requires these techniques as part of the biofeedback system. There is evidence that this may be appropriate in anismus and solitary rectal ulcer syndrome. However, the assessment of these difficult conditions and the interpretation of the results are probably at present best confined to specialist units. PMID:8074392
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fox, K. M.; Edwards, T. B.
In this report, the Savannah River National Laboratory provides chemical analyses and Product Consistency Test (PCT) results for 14 simulated high level waste glasses fabricated by the Pacific Northwest National Laboratory. The results of these analyses will be used as part of efforts to revise or extend the validation regions of the current Hanford Waste Treatment and Immobilization Plant glass property models to cover a broader span of waste compositions. The measured chemical composition data are reported and compared with the targeted values for each component for each glass. All of the measured sums of oxides for the study glassesmore » fell within the interval of 96.9 to 100.8 wt %, indicating recovery of all components. Comparisons of the targeted and measured chemical compositions showed that the measured values for the glasses met the targeted concentrations within 10% for those components present at more than 5 wt %. The PCT results were normalized to both the targeted and measured compositions of the study glasses. Several of the glasses exhibited increases in normalized concentrations (NCi) after the canister centerline cooled (CCC) heat treatment. Five of the glasses, after the CCC heat treatment, had NC B values that exceeded that of the Environmental Assessment (EA) benchmark glass. These results can be combined with additional characterization, including X-ray diffraction, to determine the cause of the higher release rates.« less
NASA Technical Reports Server (NTRS)
Battles, August H.; Knapka, Joseph T.; Stevens, Bruce R.; Lewis, Laura; Lang, Marie T.; Gruendel, Douglas J.
1991-01-01
Rats were fed an irradiated high-moisture diet (KSC-25) with or without access to a water bottle. Physiologic values were compared between these two groups and a group of rats fed a purified diet. Hematologic and serum biochemical values, urine specific gravity, and intestinal enzyme activities were determined from samples collected from the three groups of rats. Sprague Dawley rats (n=32) fed the irradiated high-moisture diet with or without a water bottle were the test animals. Rats (n=16) fed an irradiated purified diet and water provided via a water bottle were the control group. The purified diet formulation, modified AIN-76A, is a commonly used purified diet for laboratory rodents. All rats remained alert and healthy throughout the study. A comparison of the physiologic values of rats in this study with reported normal values indicated that all of the rats in the study were in good health. Significant differences (P less than 0.05) of the physiologic values from each rat group are reported.
Chen, Ming-Shu; Wu, Ming-Hsun; Lin, Chih-Ming
2014-04-30
The traditional criteria for acceptability of analytic quality may not be objective in clinical laboratories. To establish quality control procedures intended to enhance Westgard multi-rules for improving the quality of clinical biochemistry tests, we applied the Cp and Cpk quality-control indices to monitor tolerance fitting and systematic variation of clinical biochemistry test results. Daily quality-control data of a large Taiwanese hospital in 2009 were analyzed. The test items were selected based on an Olympus biochemistry machine and included serum albumin, aspartate aminotransferase, cholesterol, glucose and potassium levels. Cp and Cpk values were calculated for normal and abnormal levels, respectively. The tolerance range was estimated with data from 50 laboratories using the same instruments and reagents. The results showed a monthly trend of variation for the five items under investigation. The index values of glucose were lower than those of the other items, and their values were usually <2. In contrast to the Cp value for cholesterol, Cpk of cholesterol was lower than 2, indicating a systematic error that should be further investigated. This finding suggests a degree of variation or failure to meet specifications that should be corrected. The study indicated that Cp and Cpk could be applied not only for monitoring variations in quality control, but also for revealing inter-laboratory qualitycontrol capability differences.
Homogenization of the lipid profile values.
Pedro-Botet, Juan; Rodríguez-Padial, Luis; Brotons, Carlos; Esteban-Salán, Margarita; García-Lerín, Aurora; Pintó, Xavier; Lekuona, Iñaki; Ordóñez-Llanos, Jordi
Analytical reports from the clinical laboratory are essential to guide clinicians about what lipid profile values should be considered altered and, therefore, require intervention. Unfortunately, there is a great heterogeneity in the lipid values reported as "normal, desirable, recommended or referenced" by clinical laboratories. This can difficult clinical decisions and be a barrier to achieve the therapeutic goals for cardiovascular prevention. A recent international recommendation has added a new heterogeneity factor for the interpretation of lipid profile, such as the possibility of measuring it without previous fasting. All this justifies the need to develop a document that adapts the existing knowledge to the clinical practice of our health system. In this regard, professionals from different scientific societies involved in the measurement and use of lipid profile data have developed this document to establish recommendations that facilitate their homogenization. Copyright © 2017. Publicado por Elsevier España, S.L.U.
Coplen, Tyler B.; Wassenaar, Leonard I
2015-01-01
RationaleAlthough laser absorption spectrometry (LAS) instrumentation is easy to use, its incorporation into laboratory operations is not easy, owing to extensive offline manipulation of comma-separated-values files for outlier detection, between-sample memory correction, nonlinearity (δ-variation with water amount) correction, drift correction, normalization to VSMOW-SLAP scales, and difficulty in performing long-term QA/QC audits.MethodsA Microsoft Access relational-database application, LIMS (Laboratory Information Management System) for Lasers 2015, was developed. It automates LAS data corrections and manages clients, projects, samples, instrument-sample lists, and triple-isotope (δ17O, δ18O, and δ2H values) instrumental data for liquid-water samples. It enables users to (1) graphically evaluate sample injections for variable water yields and high isotope-delta variance; (2) correct for between-sample carryover, instrumental drift, and δ nonlinearity; and (3) normalize final results to VSMOW-SLAP scales.ResultsCost-free LIMS for Lasers 2015 enables users to obtain improved δ17O, δ18O, and δ2H values with liquid-water LAS instruments, even those with under-performing syringes. For example, LAS δ2HVSMOW measurements of USGS50 Lake Kyoga (Uganda) water using an under-performing syringe having ±10 % variation in water concentration gave +31.7 ± 1.6 ‰ (2-σ standard deviation), compared with the reference value of +32.8 ± 0.4 ‰, after correction for variation in δ value with water concentration, between-sample memory, and normalization to the VSMOW-SLAP scale.ConclusionsLIMS for Lasers 2015 enables users to create systematic, well-founded instrument templates, import δ2H, δ17O, and δ18O results, evaluate performance with automatic graphical plots, correct for δ nonlinearity due to variable water concentration, correct for between-sample memory, adjust for drift, perform VSMOW-SLAP normalization, and perform long-term QA/QC audits easily. Published in 2015. This article is a U.S. Government work and is in the public domain in the USA.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Habte, Aron; Sengupta, Manajit; Andreas, Afshin
Accurate solar radiation measurements require properly installed and maintained radiometers with calibrations traceable to the World Radiometric Reference. This study analyzes the performance of 51 commercially available and prototype radiometers used for measuring global horizontal irradiances or direct normal irradiances. These include pyranometers, pyrheliometers, rotating shadowband radiometers, and a pyranometer with an internal shading mask deployed at the National Renewable Energy Laboratory's (NREL) Solar Radiation Research Laboratory. The radiometers in this study were deployed for one year (from April 1, 2011, through March 31, 2012), and their measurements were compared under clear-sky, partly cloudy, and mostly cloudy conditions to referencemore » values of low estimated measurement uncertainties. The intent of this paper is to present a general overview of each radiometer's performance based on the instrumentation and environmental conditions available at NREL.« less
An unusual case of hyperthyroidism associated with jaundice and hypercalcaemia.
Klangjareonchai, Theerawut
2012-05-08
A 51-year-old woman with rheumatoid arthritis presented with a 3 month history of painless jaundice and significant weight loss and constipation. Laboratory values were consistent with hyperthyroidism, cholestatic jaundice and parathyroid hormone-independent hypercalcaemia. Three months after beginning of methimazole, euthyroidism was achieved and serum adjusted calcium, total and direct bilirubin levels were normal.
Normal Physiological Values for Conscious Pigs Used in Biomedical Research
1989-05-01
6. Cardiovascular and Pulmonary Functions........... 18 TABLE 7. Bioenergetics..................................... 19 TABLE 8. Renal Function...procedure developed in our laboratory. Plasma concentrations of aldosterone, cortisol, total T3, total T4, free T4, insulin and glucagon were...pulmonary vascular resistance , alveolar ventilation, alveolar ventilation/perfusion ratio, arterial 02 transport, tissue 02 extraction ratio, pulmonary
[Hypothyreodism. From the latent functional disorder up to coma].
Hintze, G; Derwahl, M
2010-05-01
An autoimmune thyroiditis represents the main reason of hypothyroidism, defined as a lack of thyroid hormone. This autoimmune process results in destruction of functioning thyroid follicles. While subclinical or latent hypothyroidism is defined on the basis of laboratory values (an elevation of TSH with normal peripheral hormone levels), the typical signs and symptoms are associated with hypothyroidism. In about 80% of cases antibodies against thyroid peroxidase can be measured, but only in about 40-50% of cases antibodies against thyroglobulin are detectable. If hypothyrodism has been diagnosed, substitution with levothyroxine should be initiated, with the therapeutic goal to decrease TSH level to the lower normal range. In cases of subclinical hypothyroidism, levothyroxine medication should be started in patients with a high TSH value, positive antibodies and/or the typical ultrasound of autoimmune thyroiditis. However, substitution with levothyroxine in any case of elevated TSH values should be avoided.
Conti, A A; Conti, A; Gensini, G F
2006-09-01
Normality characterises in medicine any possible qualitative or quantitative situation whose absence implies an illness or a state of abnormality. The illness concept was first a philosophical one. But the use of mathematics in the study of biological events, which began with Galton (1822-1911) and with Pearson (1857-1936), changed the frame of reference. In the second part of the 19th century mathematics was used to study the distribution of some biological characteristics in the evolution of the species. Around 1900, statistics became the basis for the study of the diffusion of the illnesses. Half a century later statistics made possible the transition from the description of single cases to groups of cases. Even more important is the concept of "normality" in laboratory medicine. In this field the search for the "perfect norm" was, and possibly still is, under way. The widespread use of statistics in the laboratory has allowed the definition, in a certain sense, of a new normality. This is the reason why the term "reference value" has been introduced. However, even the introduction of this new term has merely shifted the problem, and not resolved it.
Immunological monitoring of dry-cleaning shop workers--exposure to tetrachloroethylene.
Andrýs, C; Hanovcová, I; Chýlková, V; Tejral, J; Eminger, S; Procházková, J
1997-09-01
A panel of immunological parameters has been examined in a group of dry-cleaning workers (n = 21) and in a control group of administrators (n = 16) from the same plant. The results were also compared to long-term laboratory reference values (LRV) (n = 14-311). External exposure to tetrachloroethylene (PER) was represented by TWA (8 h) values in the range 11-752 mg PER/m3. Biological monitoring showed an amount from 9 to 344 mg PER/m3 in exhaled air by the end of workshift. 1. The exposed dry-cleaning workers compared to the controls from the plant had statistically significant changes in metabolic activity of phagocytes, alpha 2-macroglobulin, C3 and C4 complement component, salivary secretory IgA, and blastic transformation test. Most of the values were within the range of normal values. 2. The exposed dry-cleaning workers had several abnormal immune parameters compared to the long-term laboratory values (LRV) especially in the alpha 2-macroglobulin, C3 and percentage of T-lymphocytes. Most of the changes, even those that were statistically significant, were still within the range of normal values, but they might be classified as trends or shifts away from normal (spontaneous blastic transformation, absolute number of phagocyting cells, coeruloplasmin, circulating immunocomplexes, serum lysozyme). 3. The non-exposed controls from the same plant showed both quantitative and qualitative differences when compared to the LRV. Changes were seen in IgG, C4, CSI and in increased spontaneous metabolic activity of leucocytes, total leucocyte count, absolute number of phagocyting cells, alpha 2-macroglobulin, prealbumin, C4, circulating immunocomplexes and serum lysozyme. 4. The distribution analysis of all results detected a large number of abnormal values in both groups, more in the at-risk group. 5. As inhalation was the main route of PER exposure it was concluded that the changes might represent aspects of the response of the respiratory immune system, mainly of the alveolar macrophages. Additional postinfection effects could not be excluded in both studied groups. Individual differences in immune reactivity as well as individual range of exposure should be taken into consideration.
Physical Characteristics of Laboratory Tested Concrete as a Substituion of Gravel on Normal Concrete
NASA Astrophysics Data System (ADS)
Butar-butar, Ronald; Suhairiani; Wijaya, Kinanti; Sebayang, Nono
2018-03-01
Concrete technology is highly potential in the field of construction for structural and non-structural construction. The amount uses of this concrete material raise the problem of solid waste in the form of concrete remaining test results in the laboratory. This waste is usually just discarded and not economically valuable. In solving the problem, this experiment was made new materials by using recycle material in the form of recycled aggregate which aims to find out the strength characteristics of the used concrete as a gravel substitution material on the normal concrete and obtain the value of the substitution composition of gravel and used concrete that can achieve the strength of concrete according to the standard. Testing of concrete characteristic is one of the requirements before starting the concrete mixture. This test using SNI method (Indonesian National Standard) with variation of comparison (used concrete : gravel) were 15: 85%, 25: 75%, 35:65%, 50:50 %, 75: 25%. The results of physical tests obtained the mud content value of the mixture gravel and used concrete is 0.03 larger than the standard of SNI 03-4142-1996 that is equal to 1.03%. so the need watering or soaking before use. The water content test results show an increase in the water content value if the composition of the used concrete increases. While the specific gravity value for variation 15: 85% until 35: 65% fulfilled the requirements of SNI 03-1969-1990. the other variasion show the specifics gravity value included on the type of light materials.
Sofronescu, Alina G; Ross, Meredith; Rush, Eric; Goldner, Whitney
2018-04-27
We report a case of discordant total and free testosterone values in a patient with hypogonadism and juvenile hypophosphatasia after he initiated treatment with asfotase alfa, recombinant tissue non-specific alkaline phosphatase. Total testosterone was evaluated using immunoassay pre and post initiation of therapy with asfotase alfa, and free testosterone was evaluated using radioimmunoassay and LC-MS/MS while on asfotase alfa therapy. Total testosterone measured by immunoassay was normal prior to therapy with asfotase alfa, and was low post initiation of therapy. During the same time frame, free testosterone measured using RAI and total testosterone measured using LC-MS/MS were normal on asfotase alfa therapy. This suggests assay interference with the total testosterone immunoassay. When laboratory results are discordant or do not match the clinical impression, the possibility of assay interference should be considered. Alternative laboratory methods free of the interference should be selected to evaluate these patients. ALPL gene, Approved name: Alkaline phosphatase, liver/bone/kidney, Synonym: Tissue non-specific alkaline phosphatase (TNSAP). Copyright © 2018 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
1982-01-01
Ventrex Laboratories, Inc. develops, manufactures and markets a line of medical diagnostic assays based on biochemical techniques, in particular immunochemical techniques. Their products are sold worldwide to hospitals and medical laboratories for use in testing blood samples and other biological fluids. Analysis of a patient's body fluids, compared with normal values, aids a physician in confirming or otherwise diagnosing a suspected disease condition. NERAC's rapid information retrieval has provided Ventrex invaluable up-to-date information, and has permitted large scale savings. NERAC's service was particularly important in the development of a new product in the company's Ventre/Sep line, which is used in radioimmunoassays.
Newe, Axel; Wimmer, Stefan; Neubert, Antje; Becker, Linda; Prokosch, Hans-Ulrich; Ganslandt, Thomas
2015-01-01
Background The analysis of electronic health records for an automated detection of adverse drug reactions is an approach to solve the problems that arise from traditional methods like spontaneous reporting or manual chart review. Algorithms addressing this task should be modeled on the criteria for a standardized case causality assessment defined by the World Health Organization. One of these criteria is the temporal relationship between drug intake and the occurrence of a reaction or a laboratory test abnormality. Appropriate data that would allow for developing or validating related algorithms is not publicly available, though. Methods In order to provide such data, retrospective routine data of drug administrations and temporally corresponding laboratory observations from a university clinic were extracted, transformed and evaluated by experts in terms of a reasonable time relationship between drug administration and lab value alteration. Result The result is a data corpus of 400 episodes of normalized laboratory parameter values in temporal context with drug administrations. Each episode has been manually classified whether it contains data that might indicate a temporal correlation between the drug administration and the change of the lab value course, whether such a change is not observable or whether a decision between those two options is not possible due to the data. In addition, each episode has been assigned a concordance value which indicates how difficult it is to assess. This is the first open data corpus of a computable ground truth of temporal correlations between drug administration and lab value alterations. Discussion The main purpose of this data corpus is the provision of data for further research and the provision of a ground truth which allows for comparing the outcome of other assessments of this data with the outcome of assessments made by human experts. It can serve as a contribution towards systematic, computerized ADR detection in retrospective data. With this lab value curve data as a basis, algorithms for detecting temporal relationships can be developed, and with the classification made by human experts, these algorithms can immediately be validated. Due to the normalization of the lab value data, it allows for a generic approach rather than for specific or solitary drug/lab value combinations. PMID:26301507
Kong, Mei-Fung; Chan, Serena; Wong, Yiu-Chung
2008-01-01
The proficiency testing (PT) program for 97 worldwide laboratories for determining total arsenic, cadmium, and lead in seawater shrimp under the auspices of the Asia-Pacific Laboratory Accreditation Cooperation (APLAC) is discussed. The program is one of the APLAC PT series whose primary purposes are to establish mutual agreement on the equivalence of the operation of APLAC member laboratories and to take corrective actions if testing deficiencies are identified. Pooled data for Cd and Pb were normally distributed with interlaboratory variations of 21.9 and 34.8%, respectively. The corresponding consensus mean values estimated by robust statistics were in good agreement with those obtained in the homogeneity tests. However, a bimodal distribution was observed from the determination of total As, in which 14 out of 74 participants reported much smaller values (0.482-6.4 mg/kg) as compared with the mean values of 60.9 mg/kg in the homogeneity test. The use of consensus mean is known to have significant deviation from the true value in bi- or multimodal distribution. Therefore, the mode value, a better estimate of central tendency, was chosen to assess participants' performance for total As. Estimates of the overall uncertainty from participants varied in this program, and some were recommended to acquire more comprehensive exposure toward important criteria as stipulated in ISO/IEC 17025.
Variability in monthly serum bicarbonate measures in hemodialysis patients: a cohort study.
Patel, Ravi; Paredes, William; Hall, Charles B; Nader, Mark A; Sapkota, Deepak; Folkert, Vaughn W; Abramowitz, Matthew K
2015-12-21
Some nephrologists have advocated an individualized approach to the prescription of bicarbonate hemodialysis. However, the utility of monthly serum bicarbonate levels for guiding and evaluating such treatment decisions has not been evaluated. We sought to define the variability of these measurements and to determine factors that are associated with month-to-month variability in pre-dialysis serum bicarbonate. We examined the monthly variability in serum bicarbonate measurements among 181 hemodialysis patients admitted to a free-standing dialysis unit in the Bronx, NY from 1/1/2008-6/30/2012. All patients were treated with a uniform bicarbonate dialysis prescription (bicarbonate 35 mEq/L, acetate 8 mEq/L). Pre-dialysis serum bicarbonate values were obtained from monthly laboratory reports. Month-to-month variability was defined using a rolling measurement for each time point. Only 34 % of high serum bicarbonate values (>26 mEq/L) remained high in the subsequent month, whereas 60 % converted to normal (22-26 mEq/L). Of all low values (<22 mEq/L), 41 % were normal the following month, while 58 % remained low. Using the mean 3-month bicarbonate, only 29 % of high values remained high in the next 3-month period. In multivariable-adjusted longitudinal models, both low and high serum bicarbonate values were associated with greater variability than were normal values (β = 0.12 (95 % CI 0.09-0.15) and 0.24 (0.18 to 0.29) respectively). Variability decreased with time, and was significantly associated with age, phosphate binder use, serum creatinine, potassium, and normalized protein catabolic rate. Monthly pre-dialysis serum bicarbonate levels are highly variable. Even if a clinician takes no action, approximately 50 % of bicarbonate values outside a normal range of 22-26 mEq/L will return to normal in the subsequent month. The decision to change the bicarbonate dialysis prescription should not be based on a single bicarbonate value, and even a 3-month mean may be insufficient.
Gemfibrozil hepatotoxicity: a case report.
Domínguez Tordera, Patricia; Comellas Alabern, José Francisco; Ronda Rivero, Félix
2011-10-01
A 55-year-old woman was admitted to our hospital for management of thoracic trauma and bone fractures. One month after admission she started to receive gemfibrozil for hypertriglyceridemia. In the second month of admission, the patient complained of nausea and malaise. Laboratory value showed an acute hepatitis with raised AST, ALT. The abdominal ultrasound scan was normal, and viral serologic tests were negative. Gemfibrozil was discontinued and in a few days AST and ALT levels returned to normal. Gemfibrozil-induced hepatitis is a rare event but should be considered in the differential diagnoses of hepatitis in which no other obvious alternative cause is found.
Calzada-Contreras, Adriana; Moreno-Hernández, Manuel; Castillo-Torres, Noemi Patricia; Souto-Rosillo, Guadalupe; Hernández-Juárez, Jesús; Ricardo-Moreno, María Tania; Sánchez-Fernández, Maria Guadalupe de Jesús; García-González, América; Majluf-Cruz, Abraham
2012-01-01
The blood coagulation system maintains the blood in a liquid state and bleeding and thrombosis are the manifestations of its malfunction. Blood coagulation laboratory evaluates the physiology of this system. To establish both, the reference values for several tests performed at the blood coagulation laboratory as well as the utility of the pooled plasma to perform these assays. MATERIAL AND: In this descriptive, cross-sectional, randomized study, we collected plasma from Mexican Mestizos. Each pooled plasma was prepared with the plasma from at least 20 blood donors. We performed screening and special tests and the Levey-Jennings graphs were built and interpreted after each pass. Results of the tests were analyzed and their distribution was established using the Kolmogorov-Smirnov test. To establish the reference values we used 95% confidence intervals. We collected 72 pooled plasmas. The distribution for PT, APTT, and TT tests was abnormal. Although the PT test showed a bimodal distribution it was normal for factor VII. The reference values for the hemostatic, anticoagulant, and fibrinolytic factors were different from those suggested by the manufacturers. We established the reference values for the blood coagulation tests in the adult Mexican population. We have shown that the pooled plasma must be used for the screening tests. We suggest that each clinical laboratory should establish its own reference values (at least for the screening tests). To reach this objective, we encourage the use of the pooled plasma.
Huang, Yunda; Huang, Ying; Moodie, Zoe; Li, Sue; Self, Steve
2014-01-01
Summary In biomedical research such as the development of vaccines for infectious diseases or cancer, measures from the same assay are often collected from multiple sources or laboratories. Measurement error that may vary between laboratories needs to be adjusted for when combining samples across laboratories. We incorporate such adjustment in comparing and combining independent samples from different labs via integration of external data, collected on paired samples from the same two laboratories. We propose: 1) normalization of individual level data from two laboratories to the same scale via the expectation of true measurements conditioning on the observed; 2) comparison of mean assay values between two independent samples in the Main study accounting for inter-source measurement error; and 3) sample size calculations of the paired-sample study so that hypothesis testing error rates are appropriately controlled in the Main study comparison. Because the goal is not to estimate the true underlying measurements but to combine data on the same scale, our proposed methods do not require that the true values for the errorprone measurements are known in the external data. Simulation results under a variety of scenarios demonstrate satisfactory finite sample performance of our proposed methods when measurement errors vary. We illustrate our methods using real ELISpot assay data generated by two HIV vaccine laboratories. PMID:22764070
Guo, Wei; Song, Binbin; Shen, Junfei; Wu, Jiong; Zhang, Chunyan; Wang, Beili; Pan, Baishen
2015-08-25
To establish an indirect reference interval based on the test results of alanine aminotransferase stored in a laboratory information system. All alanine aminotransferase results were included for outpatients and physical examinations that were stored in the laboratory information system of Zhongshan Hospital during 2014. The original data were transformed using a Box-Cox transformation to obtain an approximate normal distribution. Outliers were identified and omitted using the Chauvenet and Tukey methods. The indirect reference intervals were obtained by simultaneously applying nonparametric and Hoffmann methods. The reference change value was selected to determine the statistical significance of the observed differences between the calculated and published reference intervals. The indirect reference intervals for alanine aminotransferase of all groups were 12 to 41 U/L (male, outpatient), 12 to 48 U/L (male, physical examination), 9 to 32 U/L (female, outpatient), and 8 to 35 U/L (female, physical examination), respectively. The absolute differences when compared with the direct results were all smaller than the reference change value of alanine aminotransferase. The Box-Cox transformation combined with the Hoffmann and Tukey methods is a simple and reliable technique that should be promoted and used by clinical laboratories.
Biomarkers to monitor safety in people on art and risk of mortality.
Bansi, Loveleen; Gazzard, Brian; Post, Frank; Phillips, Andrew; Johnson, Margaret; Hill, Teresa; Gilson, Richard; Leen, Clifford; Walsh, John; Fisher, Martin; Sabin, Caroline
2012-05-01
Though patients with HIV now have near normal life expectancies as a result of antiretroviral treatment, long-term adverse effects are of growing concern. Using time-updated laboratory measurements, we use several methods to derive a score that can be used to identify individuals at high risk of mortality. Patients who started highly active antiretroviral therapy after 2000 and had ≥1 CD4 count, viral load, and laboratory marker recorded after the date of starting highly active antiretroviral therapy were included in the analyses. Laboratory markers were stratified into quintiles and associations between each marker and mortality was assessed using Poisson regression. The estimates of the final model were used to construct a score for predicting short-term mortality. Several methods, including multiple imputation, were used for analyzing records with missing measurements. Of the 7232 patients included in this analysis, 247 died over 24,796 person-years of follow-up, giving an overall mortality rate of 1.00 (95% confidence interval: 0.87 to 1.12) per 100 person-years. Regardless of which method was used to deal with missing data, albumin, alkaline phosphatase, and hemoglobin were independently associated with mortality. Alanine transaminase was independently associated with mortality when patients with missing measurements were assumed to have measurements within the normal range. The C-statistics for all models ranged from 0.76 to 0.78. Measures of alanine transaminase, albumin, alkaline phosphatase, and hemoglobin in the normal range were predictive of mortality, and hence we suggest using a scoring system to predict mortality which relies on the raw values of these 4 laboratory markers.
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
The Quarterly Environmental Data Summary (QEDS) for the fourth quarter of 1997 is prepared in support of the Weldon Spring Site Remedial Action Project Federal Facilities Agreement. The data presented constitute the QEDS. The data were received from the contract laboratories, verified by the Weldon Spring Site verification group and, except for air monitoring data and site KPA generated data (uranium analyses), merged into the data base during the fourth quarter of 1997. Air monitoring data presented are the most recent complete sets of quarterly data. Air data are not stored in the data base and KPA data are notmore » merged into the regular data base. Significant data, defined as data values that have exceeded defined ``above normal`` level 2 values, are discussed in this letter for Environmental Monitoring Plan (EMP) generated data only. Above normal level 2 values are based, in ES and H procedures, on historical high values, DOE Derived Concentration Guides (DCGs), NPDES limits and other guidelines. The procedures also establish actions to be taken in response to such data. Data received and verified during the fourth quarter were within a permissible range of variability except for those which are detailed.« less
A study examining the bias of albumin and albumin/creatinine ratio measurements in urine.
Jacobson, Beryl E; Seccombe, David W; Katayev, Alex; Levin, Adeera
2015-10-01
The objective of the study was to examine the bias of albumin and albumin/creatinine (ACR) measurements in urine. Pools of normal human urine were augmented with purified human serum albumin to generate a series of 12 samples covering the clinical range of interest for the measurement of ACR. Albumin and creatinine concentrations in these samples were analyzed three times on each of 3 days by 24 accredited laboratories in Canada and the USA. Reference values (RV) for albumin measurements were assigned by a liquid chromatography-tandem mass spectrometry (LC-MS/MS) comparative method and gravimetrically. Ten random urine samples (check samples) were analyzed as singlets and albumin and ACR values reported according to the routine practices of each laboratory. Augmented urine pools were shown to be commutable. Gravimetrically assigned target values were corrected for the presence of endogenous albumin using the LC-MS/MS comparative method. There was excellent agreement between the RVs as assigned by these two methods. All laboratory medians demonstrated a negative bias for the measurement of albumin in urine over the concentration range examined. The magnitude of this bias tended to decrease with increasing albumin concentrations. At baseline, only 10% of the patient ACR values met a performance limit of RV ± 15%. This increased to 84% and 86% following post-analytical correction for albumin and creatinine calibration bias, respectively. International organizations should take a leading role in the standardization of albumin measurements in urine. In the interim, accuracy based urine quality control samples may be used by clinical laboratories for monitoring the accuracy of their urinary albumin measurements.
Evaluating phenanthrene sorption on various wood chars
James, G.; Sabatini, D.A.; Chiou, C.T.; Rutherford, D.; Scott, A.C.; Karapanagioti, H.K.
2005-01-01
A certain amount of wood char or soot in a soil or sediment sample may cause the sorption of organic compounds to deviate significantly from the linear partitioning commonly observed with soil organic matter (SOM). Laboratory produced and field wood chars have been obtained and analyzed for their sorption isotherms of a model solute (phenanthrene) from water solution. The uptake capacities and nonlinear sorption effects with the laboratory wood chars are similar to those with the field wood chars. For phenanthrene aqueous concentrations of 1 ??gl-1, the organic carbon-normalized sorption coefficients (log Koc) ranging from 5.0 to 6.4 for field chars and 5.4-7.3 for laboratory wood chars, which is consistent with literature values (5.6-7.1). Data with artificial chars suggest that the variation in sorption potential can be attributed to heating temperature and starting material, and both the quantity and heterogeneity of surface-area impacts the sorption capacity. These results thus help to corroborate and explain the range of log Koc values reported in previous research for aquifer materials containing wood chars. ?? 2004 Elsevier Ltd. All rights reserved.
Blunt abdominal trauma in children.
Schonfeld, Deborah; Lee, Lois K
2012-06-01
This review will examine the current evidence regarding pediatric blunt abdominal trauma and the physical exam findings, laboratory values, and radiographic imaging associated with the diagnosis of intra-abdominal injuries (IAI), as well as review the current literature on pediatric hollow viscus injuries and emergency department disposition after diagnosis. The importance of the seat belt sign on physical examination and screening laboratory data remains controversial, although screening hepatic enzymes are recommended in the evaluation of nonaccidental trauma to identify occult abdominal organ injuries. Focused Assessment with Sonography for Trauma (FAST) has modest sensitivity for hemoperitoneum and IAI in the pediatric trauma patient. Patients with concern for undiagnosed IAI, including bowel injury, may be considered for hospital admission and serial abdominal exams without an increased risk of complications, if an exploratory laparotomy is not performed emergently. Although the FAST exam is not recommended as the sole screening tool to rule out IAI in hemodynamically stable trauma patients, it may be used in conjunction with the physical exam and laboratory findings to identify children at risk for IAI. Children with a normal physical exam and normal abdominal CT may not require routine hospitalization after blunt abdominal trauma.
Taieb, Joëlle; Mendez Lozano, Daniel H; Benattar, Clarisse; Messaoudi, Chérif; Poüs, Christian
2007-12-01
We assessed a new estradiol (E2) immunoassay on the Architect-i2000 (Abbott Laboratories) for monitoring ovulation stimulation for IVF-ET and re-establishing clinical cut-off points. The method has been modified to improve E2 measurements especially at normal and low concentrations. E2 was determined for 552 samples, from 83 women, presenting normal follicular status and undergoing 100 cycles of IVF treatment. We assessed the value of this assay for down-regulation of E2 concentration limit using gonadoliberin-releasing hormone agonist (GnRHa), and monitoring of the ovarian hyperstimulation, expected range of E2 per mature follicle prior to the administration of exogenous hCG and day 3 concentration limit. We compared results with our routine method (E2-6II Advia-Centaur; Siemens-Diagnostics) for which decision-making values were known. Considering E2 concentrations obtained with the new Architect-i2000 assay for patients treated with GnRHa for 2 weeks, the cutoff-point for ovarian down-regulation should be set down at 110 pmol/L to maintain 100% of sensitivity. Considering day 3 concentration limit determination, results were not significantly different from those obtained with our routine method. The mean E2 values per mature follicle fell into the range generally expected. E2 determination with the new E2 Architect-i2000 assay could be used to monitor ovulation, in patients undergoing IVF-ET, in combination with transvaginal ultrasound.
2010-01-01
Background Follicle stimulating hormone (FSH) and anti-Müllerian hormone (AMH) represent the two most frequently utilized laboratory tests in determining ovarian reserve (OR). This study determined the clinical significance of their concordance and discordance in female infertility patients. Methods We investigated 366 consecutive infertility patients (350 reached IVF), excluding women with polycystic ovarian syndrome (PCOS). They were considered to have normal FSH and AMH if values fell within age-specific (as-) 95% confidence intervals (CI), and to suffer from diminished ovarian reserve (DOR) if FSH exceeded and/or AMH fell below those. The two hormones, thus, could be concordant (Group I), both normal (IA) or abnormal (IB), show normal AMH/abnormal FSH (Group II) or normal FSH/abnormal AMH (Group III). Oocyte yields, stratified for age categories, were then studied in each group as reflection of OR. Results Oocyte yields significantly decreased from groups IA to II to III and IB. Predictive values of as-FSH/AMH patterns changed, however, at different ages. Except at very young and very old ages, normal as-AMH better predicted higher oocytes yields than normal as-FSH, though above age 42 years normal as-FSH predicts good oocyte yields even with abnormally low AMH. Under age 42 discrepancies between as- FSH and as-AMH remain similarly predictive of oocyte yields at all ages. Discussion Concordances and discordances between as-FSH and as-AMH improve OR assessments and predictability of oocyte yields in IVF. PMID:20565808
Kopjar, Nevenka; Kasuba, Vilena; Milić, Mirta; Rozgaj, Ruzica; Zeljezić, Davor; Gajski, Goran; Mladinić, Marin; Garaj-Vrhovac, Vera
2010-06-01
The cytokinesis-block micronucleus (CBMN) assay on peripheral blood lymphocytes is one of the most important methods employed in cytogenetic biomonitoring. For the purposes of biological dosimetry, it is important to know the spontaneous frequency of a biomarker and its normal values in general population. These values are used for population databases, which should be updated regularly. In this study, MN levels were investigated in cytokinesis-blocked lymphocytes of 200 healthy male and female blood donors selected at random from the general population of Croatia. The aim was to assess the variability and determine possible influences of external and/or internal factors on the background levels of MN and to establish the cut-off value for the CBMN assay. The background frequency of MN was (6.90+/-3.32) MN (median 7 MN) and the range was 0 to 18 MN per 1000 binuclear lymphocytes. The cut-off value, which corresponds to 95th percentile of the distribution of 200 individual values, was 12.5 MN. Spontaneous formation of MN was influenced by sex, age, and smoking. Women had higher MN levels than men. However, only age and smoking significantly increased the values of all parameters evaluated by the CBMN assay. Since the existing literature data on smoking-related formation of MN are contradictory, we will continue these investigations to resolve how the number of cigarettes smoked per day and the duration of smoking in years influence the results of the CBMN assay. Our results are consistent with the background MN frequencies reported by other cytogenetic laboratories worldwide. Normal and cut-off values estimated in this study will be used to update the current general population data and as reference for occupationally or accidental exposure.
Economic impact of university veterinary diagnostic laboratories: A case study.
Schulz, Lee L; Hayes, Dermot J; Holtkamp, Derald J; Swenson, David A
2018-03-01
Veterinary diagnostic laboratories (VDLs) play a significant role in the prevention and mitigation of endemic animal diseases and serve an important role in surveillance of, and the response to, outbreaks of transboundary and emerging animal diseases. They also allow for business continuity in livestock operations and help improve human health. Despite these critical societal roles, there is no academic literature on the economic impact of VDLs. We present a case study on the economic impact of the Iowa State University Veterinary Diagnostic Laboratory (ISUVDL). We use economic contribution analysis coupled with a stakeholder survey to estimate the impact. Results suggest that the ISUVDL is responsible for $2,162.46 million in direct output, $2,832.45 million in total output, $1,158.19 million in total value added, and $31.79 million in state taxes in normal years. In an animal health emergency this increases to $8,446.21 million in direct output, $11,063.06 million in total output, $4,523.70 million in total value added, and $124.15 million in state taxes. The ISUVDL receives $4 million annually as a direct state government appropriation for operating purposes. The $31.79 million in state taxes in normal years and the $124.15 million in state taxes in an animal health emergency equates to a 795% and 3104% return on investment, respectively. Estimates of the economic impact of the ISUVDL provide information to scientists, administrators, and policymakers regarding the efficacy and return on investment of VDLs. Copyright © 2018 Elsevier B.V. All rights reserved.
Kopczak, Anna; Krewer, Carmen; Schneider, Manfred; Kreitschmann-Andermahr, Ilonka; Schneider, Harald Jörn; Stalla, Günter Karl
2015-01-01
Previous reports suggest that neuroendocrine disturbances in patients with traumatic brain injury (TBI) or aneurysmal subarachnoid hemorrhage (SAH) may still develop or resolve months or even years after the trauma. We investigated a cohort of n = 168 patients (81 patients after TBI and 87 patients after SAH) in whom hormone levels had been determined at various time points to assess the course and pattern of hormonal insufficiencies. Data were analyzed using three different criteria: (1) patients with lowered basal laboratory values; (2) patients with lowered basal laboratory values or the need for hormone replacement therapy; (3) diagnosis of the treating physician. The first hormonal assessment after a median time of three months after the injury showed lowered hormone laboratory test results in 35% of cases. Lowered testosterone (23.1% of male patients), lowered estradiol (14.3% of female patients) and lowered insulin-like growth factor I (IGF-I) values (12.1%) were most common. Using Criterion 2, a higher prevalence rate of 55.6% of cases was determined, which correlated well with the prevalence rate of 54% of cases using the physicians’ diagnosis as the criterion. Intraindividual changes (new onset insufficiency or recovery) were predominantly observed for the somatotropic axis (12.5%), the gonadotropic axis in women (11.1%) and the corticotropic axis (10.6%). Patients after TBI showed more often lowered IGF-I values at first testing, but normal values at follow-up (p < 0.0004). In general, most patients remained stable. Stable hormone results at follow-up were obtained in 78% (free thyroxine (fT4) values) to 94.6% (prolactin values). PMID:26703585
Kukuy, Olga; Livneh, Avi; Mendel, Liran; Benor, Ariel; Giat, Eitan; Perski, Oleg; Feld, Olga; Kassel, Yonatan; Ben-Zvi, Ilan; Lidar, Merav; Holtzman, Eliezer J; Leiba, Adi
2017-01-01
Familial Mediterranean fever (FMF) is an autoinflammatory disorder with episodic and persistent inflammation, which is only partially suppressed by continuous colchicine treatment. While chronic inflammation is considered an important cardiovascular risk factor in many inflammatory disorders, its impact in FMF is still disputed. We measured arterial stiffness, a marker of atherosclerotic cardiovascular disease, in a group of FMF patients, in order to evaluate the cardiovascular consequences of inflammation in FMF and the role of colchicine in their development. Eighty colchicine treated FMF patients, without known traditional cardiovascular risk factors, were randomly enrolled in the study. Demographic, genetic, clinical and laboratory data were retrieved from patient files and examinations. Arterial stiffness was measured using pulse wave velocity (PWV). The recorded values of PWV were compared with those of an age and blood pressure adjusted normal population, using internationally endorsed values. FMF patients displayed normal PWV values, with an even smaller than expected proportion of patients deviating from the 90th percentile of the reference population (5% vs. 10%, p=0.02). The lowest PWV values were recorded in patients receiving the highest dose of colchicine (≥2 mg vs. 0-1 mg, p=0.038), and in patients of North African Jewish origin, whose disease was typically more severe than that of patients of other ethnicities; both observations supporting an ameliorating colchicine effect (p=0.043). Though subjected to chronic inflammation, colchicine treated FMF patients have normal PWV. Our findings provide direct evidence for a cardiovascular protective role of colchicine in FMF.
Effects of Oritavancin on Coagulation Tests in the Clinical Laboratory.
Belley, Adam; Robson, Richard; Francis, John L; Adcock, Dorothy M; Tiefenbacher, Stefan; Rubino, Christopher M; Moeck, Greg; Sylvester, David; Dudley, Michael N; Loutit, Jeffery
2017-02-01
Previous studies have shown that some lipoglycopeptide and lipopeptide antimicrobial agents may cause falsely elevated values for some phospholipid-dependent coagulation tests. The effect of oritavancin, a lipoglycopeptide antibiotic, on coagulation test results was explored using pooled human plasma samples spiked with drug and in a clinical study after an infusion of a single 1,200-mg intravenous dose of oritavancin in normal healthy volunteers. Pooled plasma with oritavancin added ex vivo showed concentration-dependent prolongation of prothrombin time/international normalized ratio (PT/INR), activated partial thromboplastin time (aPTT), and dilute Russell viper venom time (DRVVT) test results. In contrast, oritavancin had no effect on the activated protein C resistance assay, chromogenic anti-factor Xa assay (anti-FXa), thrombin time, and an immunoassay for the laboratory diagnosis of heparin-induced thrombocytopenia. In participants that received a single dose of oritavancin, elevations in PT/INR result, aPTT, DRVVT, activated clotting time, and silica clotting time occurred, with the maximum times to resolution of test interference determined to be 12, 120, 72, 24, and 18 h, respectively. The anti-FXa assay was unaffected, whereas transient elevations in D dimer levels were observed in 30% of participants, with a maximum time to resolution of 72 h. Although oritavancin has no impact on the coagulation system in vivo, a single dose of oritavancin can produce falsely elevated values of some coagulation tests used to monitor hemostasis. The interference of oritavancin on affected tests is transient, and the test results revert to normal ranges within specified times after dosing. Copyright © 2017 American Society for Microbiology.
Effects of Oritavancin on Coagulation Tests in the Clinical Laboratory
Robson, Richard; Francis, John L.; Adcock, Dorothy M.; Tiefenbacher, Stefan; Rubino, Christopher M.; Moeck, Greg; Sylvester, David; Dudley, Michael N.; Loutit, Jeffery
2016-01-01
ABSTRACT Previous studies have shown that some lipoglycopeptide and lipopeptide antimicrobial agents may cause falsely elevated values for some phospholipid-dependent coagulation tests. The effect of oritavancin, a lipoglycopeptide antibiotic, on coagulation test results was explored using pooled human plasma samples spiked with drug and in a clinical study after an infusion of a single 1,200-mg intravenous dose of oritavancin in normal healthy volunteers. Pooled plasma with oritavancin added ex vivo showed concentration-dependent prolongation of prothrombin time/international normalized ratio (PT/INR), activated partial thromboplastin time (aPTT), and dilute Russell viper venom time (DRVVT) test results. In contrast, oritavancin had no effect on the activated protein C resistance assay, chromogenic anti-factor Xa assay (anti-FXa), thrombin time, and an immunoassay for the laboratory diagnosis of heparin-induced thrombocytopenia. In participants that received a single dose of oritavancin, elevations in PT/INR result, aPTT, DRVVT, activated clotting time, and silica clotting time occurred, with the maximum times to resolution of test interference determined to be 12, 120, 72, 24, and 18 h, respectively. The anti-FXa assay was unaffected, whereas transient elevations in D dimer levels were observed in 30% of participants, with a maximum time to resolution of 72 h. Although oritavancin has no impact on the coagulation system in vivo, a single dose of oritavancin can produce falsely elevated values of some coagulation tests used to monitor hemostasis. The interference of oritavancin on affected tests is transient, and the test results revert to normal ranges within specified times after dosing. PMID:27956417
Quarterly environmental data summary for first quarter 1998
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1998-05-01
In support of the Weldon Spring Site Remedial Action Project Federal Facilities Agreement, a copy of the Quarterly Environmental Data Summary (QEDS) for the first quarter of 1998 is enclosed. The data presented in this letter and attachment constitute the QEDS. The data were received from the contract laboratories, verified by the Weldon Spring Site verification group and, except for air monitoring data and site KPA generated data (uranium analyses), merged into the data base during the first quarter of 1998. Air monitoring data presented are the most recent complete sets of quarterly data. Air data are not stored inmore » the data base, and KPA data are not merged into the regular data base. Significant data, defined as data values that have exceeded defined {open_quotes}above normal{close_quotes} Level 2 values, are discussed in this letter for Environmental Monitoring Plan (EMP) generated data only. Above normal Level 2 values are based, in ES&H procedures, on historical high values, DOE Derived Concentration Guides (DCGs), NPDES limits and other guidelines. The procedures also establish actions to be taken in the event that {open_quotes}above normal{close_quotes} data occur. All data received and verified during the first quarter were within a permissible range of variability except for those detailed below. Above normal occurrences are cited for groundwater, air, and NPDES data. There were none for springs or surface water. The following discussion offers a brief summary of the data merged during the first quarter that exceeded the above normal criteria and updates on past reported above normal data. The attached tables present the most recent data for air and the data merged into the data base during the first quarter 1998 for groundwater, NPDES, surface water, and springs. Graphs showing concentrations of selected contaminants of concern at some of the critical locations have also been included in this QEDS. The graphs are discussed in the separate sections.« less
Voils, Stacy A; Martin, Erika J; Mohammed, Bassem M; Bayrlee, Ahmad; Brophy, Donald F
2015-06-01
We assess the in-vivo relationship between international normalized ratio (INR) and global coagulation tests in patients with life-threatening bleeding who received prothrombin complex concentrate (PCC) for warfarin reversal. This was a prospective pilot study in adult patients with intracranial bleeding related to anticoagulation with warfarin. Thromboelastography (TEG), thrombin generation parameters and INR were assessed at baseline, 30 min, 2 and 24 h after PCC. Changes in laboratory parameters and relationship between INR and global coagulation tests were assessed over time. Eight patients mean [standard deviation (SD)] age 72 (16) were included and received mean (SD) dose of PCC 24 (5) units/kg. Four patients died during the study, all with INR values more than 1.5 thirty minutes after PCC. Mean (SD) INR was 3.0 (1.3) and decreased significantly to 1.8 (0.48) thirty minutes after PCC (P < 0.01). Baseline endogenous thrombin potential and thrombin peak were 890 nmol/min and 123 nmol and increased significantly to 1943 nmol/min (P < 0.01) and 301 nmol (P < 0.01) 30 min after PCC administration. Reaction (R)-time decreased significantly (P = 0.02), and maximum amplitude and overall coagulation index (CI) significantly increased during treatment (P < 0.01, respectively). Thrombin generation and TEG values corrected after PCC administration; however, INR did not fully correct. Patients that died tended to be older with prolonged INR values across the study period. INR and TEG values correlated well with thrombin generation before administration of PCC, but this relationship was lost afterward.
NASA Astrophysics Data System (ADS)
Thomas, M. A.
2016-12-01
The Waste Isolation Pilot Plant (WIPP) is the only deep geological repository for transuranic waste in the United States. As the Science Advisor for the WIPP, Sandia National Laboratories annually evaluates site data against trigger values (TVs), metrics whose violation is indicative of conditions that may impact long-term repository performance. This study focuses on a groundwater-quality dataset used to redesign a TV for the Culebra Dolomite Member (Culebra) of the Permian-age Rustler Formation. Prior to this study, a TV violation occurred if the concentration of a major ion fell outside a range defined as the mean +/- two standard deviations. The ranges were thought to denote conditions that 95% of future values would fall within. Groundwater-quality data used in evaluating compliance, however, are rarely normally distributed. To create a more robust Culebra groundwater-quality TV, this study employed the randomization test, a non-parametric permutation method. Recent groundwater compositions considered TV violations under the original ion concentration ranges are now interpreted as false positives in light of the insignificant p-values calculated with the randomization test. This work highlights that the normality assumption can weaken as the size of a groundwater-quality dataset grows over time. Non-parametric permutation methods are an attractive option because no assumption about the statistical distribution is required and calculating all combinations of the data is an increasingly tractable problem with modern workstations. Sandia National Laboratories is a multi-program laboratory managed and operated by Sandia Corporation, a wholly owned subsidiary of Lockheed Martin Corporation, for the U.S. Department of Energy's National Nuclear Security Administration under contract DE-AC04-94AL85000. This research is funded by WIPP programs administered by the Office of Environmental Management (EM) of the U.S. Department of Energy. SAND2016-7306A
Favaloro, Emmanuel J; Thom, Jim; Patterson, David; Just, Sarah; Baccala, Maria; Dixon, Tracy; Meiring, Muriel; Koutts, Jerry; Rowell, John; Baker, Ross
2009-09-01
We performed a retrospective audit of cross-laboratory testing of desmopressin and factor concentrate therapy to assess the potential utility of supplementary testing using the PFA-100 with functional von Willebrand factor (VWF) activity testing. Data were evaluated for a large number of patients with von Willebrand disease of type 1, type 2A or type 2M, as well as a comparative subset of individuals with haemophilia or carriers of haemophilia. Laboratory testing comprised pre and postdesmopressin, or pre and postconcentrate, evaluation of factor VIII, VWF antigen (VWF:Ag) and VWF ristocetin cofactor activity as traditionally performed, supplemented with collagen-binding (VWF:CB) testing and PFA-100 closure times. In brief, both therapies tended to normalize VWF test parameters and closure times in individuals with type 1 von Willebrand disease, with the level of correction in closure times related to the level of normalization of VWF, particularly the VWF:CB. However, although occasional correction of closure times was observed in patients with type 2A or type 2M von Willebrand disease, these did not in general normalize PFA-100 closure times either with desmopressin or factor concentrate therapy. In these patients, improvement in closure times was more likely in those in whom VWF:CB values normalized or when VWF:CB/VWF:Ag ratios normalized. This study confirms that there is a strong relationship between the presenting levels of plasma VWF and PFA-100 closure times, and that the supplementary combination of PFA-100 and VWF:CB testing might provide added clinical utility to current broadly applied testing strategies limited primarily to VWF:Ag, VWF ristocetin cofactor and factor VIII:coagulant. Future prospective investigations are warranted to validate these relationships and to investigate their therapeutic implications.
Brain, Keith L; Kay, Jonathan; Shine, Brian
2006-11-01
Despite the rarity of pheochromocytoma, diagnosis is important because of the dangers of uncontrolled severe hypertension and the availability of very effective surgical treatment. Urinary or plasma catecholamines or catecholamine derivatives are commonly used to screen for pheochromocytomas before imaging, but data from 24-h urinary metanephrine results, patient age, and sex may better predict tumors in populations with a low pretest probability. We retrospectively studied outcomes of an unselected population (1819 patients) referred to a tertiary hospital laboratory for urinary metanephrine testing and investigated the usefulness of some simple derivative measures for detecting pheochromocytoma. We normalized values for urinary 24-h excretion of metanephrine, normetanephrine, and 3-methoxytyramine by dividing by an age- and sex-specific reference range. We then compared pheochromocytoma prediction by the use of products of these normalized measures with the gold standard of biopsy-confirmed tumor. The product of the excretion of normalized metanephrine (nMAD) and normalized normetanephrine (nNMT) (nMAD.nNMT) was a highly sensitive (100%) and specific (99.1%) measure, yielding a positive predictive value of 82%. ROC curves were not improved by including the normalized 3-methoxytyramine concentrations in the product. The test for nMAD.nNMT gave higher sensitivity and specificity than the tests for either substance alone. The test for nMAD.nNMT is a useful measure for identifying pheochromocytoma in a population with a low pretest probability.
Søeby, Karen; Jensen, Peter Bjødstrup; Werge, Thomas; Sørensen, Steen
2015-09-01
The knowledge of physiological fluctuation and variation of even commonly used biochemical quantities in extreme age groups and during development is sparse. This challenges the clinical interpretation and utility of laboratory tests in these age groups. To explore the utility of hospital laboratory data as a source of information, we analyzed enzymatic plasma creatinine as a model analyte in two large pediatric hospital samples. Plasma creatinine measurements from 9700 children aged 0-18 years were obtained from hospital laboratory databases and partitioned into high-resolution gender- and age-groups. Normal probability plots were used to deduce parameters of the normal distributions from healthy creatinine values in the mixed hospital datasets. Furthermore, temporal trajectories were generated from repeated measurements to examine developmental patterns in periods of changing creatinine levels. Creatinine shows great age dependence from birth throughout childhood. We computed and replicated 95% reference intervals in narrow gender and age bins and showed them to be comparable to those determined in healthy population studies. We identified pronounced transitions in creatinine levels at different time points after birth and around the early teens, which challenges the establishment and usefulness of reference intervals in those age groups. The study documents that hospital laboratory data may inform on the developmental aspects of creatinine, on periods with pronounced heterogeneity and valid reference intervals. Furthermore, part of the heterogeneity in creatinine distribution is likely due to differences in biological and chronological age of children and should be considered when using age-specific reference intervals.
Chuntarut, A; Tientadakul, P; Wongkrajang, P
2016-06-01
The Thailand National External Quality Assessment Scheme (NEQAS) for blood coagulation was established in 2005. The objective of this study was to collect data of coagulation laboratory practices and satisfaction of NEQAS member. Two hundred seventy-six questionnaires were sent to laboratories that are members of NEQAS to obtain data relating to coagulation laboratory practice and satisfaction in 2014. Data from this survey were compared with data from the survey conducted in 2005 to evaluate levels of improvement. Of 276 questionnaires sent, 212 (76.8%) were returned. Improvements were characterized by the number of laboratories that (i) decreased use of 3.8% sodium citrate as anticoagulant; (ii) implemented use of at least two control levels for internal quality control; and (iii) implemented reporting of reference values with results, as well as establishing their own reference range and using geometric mean as the denominator for international normalized ratio calculation. For overall satisfaction, 179 of 206 (86.9%) participant laboratories reported being satisfied or very satisfied. Improvements in coagulation laboratory practices in Thailand were observed in every step of the total testing process. However, additional improvements are still needed, such as determination and use of a local reference range. © 2016 John Wiley & Sons Ltd.
Kiriyama, Tomonari; Kumita, Shin-Ichiro; Moroi, Masao; Nishimura, Tsunehiko; Tamaki, Nagara; Hasebe, Naoyuki; Kikuchi, Kenjiro
2015-01-01
The severity of impaired fatty acid utilization in the myocardium can predict cardiac death in asymptomatic patients on hemodialysis. However, interpretive variability and its impact on the prognostic value of myocardial fatty acid imaging are unknown. A total of 677 patients who received hemodialysis for ≥ 20 years and had one or more cardiovascular risk factors underwent (123)I-labeled β-methyl iodophenyl-pentadecanoic acid (BMIPP) single-photon emission computed tomography (SPECT) at 48 hospitals across Japan. SPECT images were interpreted by experts at the nuclear core laboratory and by readers with varying skill levels at clinical centers, based on the standard 17-segment model and 5-point scoring systems, independently. The κ values only reached fair agreement both for overall impression (κ=0.298, normal vs. abnormal) and for categorical impression (κ=0.244, normal vs. mildly abnormal vs. severely abnormal). The normalcy rate was lower in readers at the clinical centers (60.9%) than in experts (69.9%). In contrast to the results assessed by experts, a Kaplan-Meier analysis based on the interpretation by readers at the clinical centers failed to distinguish the risk of events in patients with normal scans from that of patients with mildly abnormal scans. Considerable variability and its impact on prognostic value were observed in the visual interpretation of BMIPP SPECT images between experts and readers at the clinical centers.
Kang, Ju-Hee; Vanderstichele, Hugo; Trojanowski, John Q; Shaw, Leslie M
2012-04-01
The xMAP-Luminex multiplex platform for measurement of Alzheimer's disease (AD) cerebrospinal fluid (CSF) biomarkers using Innogenetics AlzBio3 immunoassay reagents that are for research use only has been shown to be an effective tool for early detection of an AD-like biomarker signature based on concentrations of CSF Aβ(1-42), t-tau and p-tau(181). Among the several advantages of the xMAP-Luminex platform for AD CSF biomarkers are: a wide dynamic range of ready-to-use calibrators, time savings for the simultaneous analyses of three biomarkers in one analytical run, reduction of human error, potential of reduced cost of reagents, and a modest reduction of sample volume as compared to conventional enzyme-linked immunosorbant assay (ELISA) methodology. Recent clinical studies support the use of CSF Aβ(1-42), t-tau and p-tau(181) measurement using the xMAP-Luminex platform for the early detection of AD pathology in cognitively normal individuals, and for prediction of progression to AD dementia in subjects with mild cognitive impairment (MCI). Studies that have shown the prediction of risk for progression to AD dementia by MCI patients provide the basis for the use of CSF Aβ(1-42), t-tau and p-tau(181) testing to assign risk for progression in patients enrolled in therapeutic trials. Furthermore emerging study data suggest that these pathologic changes occur in cognitively normal subjects 20 or more years before the onset of clinically detectable memory changes thus providing an objective measurement for use in the assessment of treatment effects in primary treatment trials. However, numerous previous ELISA and Luminex-based multiplex studies reported a wide range of absolute values of CSF Aβ(1-42), t-tau and p-tau(181) indicative of substantial inter-laboratory variability as well as varying degrees of intra-laboratory imprecision. In order to address these issues a recent inter-laboratory investigation that included a common set of CSF pool aliquots from controls as well as AD patients over a range of normal and pathological Aβ(1-42), t-tau and p-tau(181) values as well as agreed-on standard operating procedures (SOPs) assessed the reproducibility of the multiplex methodology and Innogenetics AlzBio3 immunoassay reagents. This study showed within-center precision values of 5% to a little more than 10% and good inter-laboratory %CV values (10-20%). There are several likely factors influencing the variability of CSF Aβ(1-42), t-tau and p-tau(181) measurements. In this review, we describe the pre-analytical, analytical and post-analytical sources of variability including sources inherent to kits, and describe procedures to decrease the variability. A CSF AD biomarker Quality Control program has been established and funded by the Alzheimer Association, and global efforts are underway to further define optimal pre-analytical SOPs and best practices for the methodologies available or in development including plans for production of a standard reference material that could provide for a common standard against which manufacturers of immunoassay kits would assign calibration standard values. Copyright © 2012 Elsevier Inc. All rights reserved.
Casadaban, Leigh C; Parvinian, Ahmad; Couture, Patrick M; Minocha, Jeet; Knuttinen, M Grace; Bui, James T; Gaba, Ron C
2014-12-01
The purpose of this article is to characterize the temporal evolution and clinical impact of laboratory liver function parameters after transjugular intrahepatic portosystemic shunt (TIPS) creation. In this single-institution retrospective study, 157 patients (98 men and 59 women; median age, 55 years) underwent TIPS between 2000 and 2012 and had 1-month hepatobiliary laboratory follow-up. Medical record review was used to compare baseline, peak, and low bilirubin, aspartate aminotransferase (AST), alanine aminotransferase (ALT), alkaline phosphatase, and international normalized ratio (INR) levels within 30 days after TIPS in surviving and dying patients to assess laboratory responses to shunt creation. TIPSs were created with a hemodynamic success rate of 98%, with median pressure gradient reduction of 13 mm Hg. Ninety-day mortality was 21%. Hepatobiliary laboratory values showed significant increases in the days after TIPS compared with baseline levels (bilirubin, 1.6 vs 3.5 mg/dL; AST, 49 vs 149 U/L; ALT, 26 vs 90 U/L; alkaline phosphatase, 97 vs 177 U/L; and INR, 1.5 vs 2.0; p<0.05 in all cases). Patients surviving to 90 days experienced statistically significant but transient laboratory value elevations-up to twofold over baseline-within days of TIPS, whereas patients dying within 90 days experienced three-to fourfold increases over a longer period that did not return to baseline. Differences in laboratory evolution were statistically significant in surviving versus dying patients. TIPS results in acute transient elevation of hepatobiliary enzymes, which may be more pronounced in patients with early mortality. An exaggerated laboratory elevation in excess of threefold greater than baseline or a prolonged increase exceeding 1 week may herald poorer clinical outcome.
Normative database of donor keratographic readings in an eye-bank setting.
Lewis, Jennifer R; Bogucki, Jennifer M; Mahmoud, Ashraf M; Lembach, Richard G; Roberts, Cynthia J
2010-04-01
To generate a normative donor topographic database from rasterstereography images of whole globes acquired in an eye-bank setting with minimal manipulation or handling. Eye-bank laboratory. In a retrospective study, rasterstereography topographic images that had been prospectively collected in duplicate of donor eyes received by the Central Ohio Lions Eye Bank between 1997 and 1999 were analyzed. Best-fit sphere (BFS) and simulated keratometry (K) values were extracted. These values were recalculated after application of custom software to correct any tilt of the mapped surfaces relative to the image plane. The mean value variances between right eyes and left eyes, between consecutive scans, and after untilting were analyzed by repeated-measures analysis of variance and t tests (P
Boatta, F; D'Alessandro, W; Gagliano, A L; Liotta, M; Milazzo, M; Rodolfo-Metalpa, R; Hall-Spencer, J M; Parello, F
2013-08-30
Shallow submarine gas vents in Levante Bay, Vulcano Island (Italy), emit around 3.6t CO2 per day providing a natural laboratory for the study of biogeochemical processes related to seabed CO2 leaks and ocean acidification. The main physico-chemical parameters (T, pH and Eh) were measured at more than 70 stations with 40 seawater samples were collected for chemical analyses. The main gas vent area had high concentrations of dissolved hydrothermal gases, low pH and negative redox values all of which returned to normal seawater values at distances of about 400m from the main vents. Much of the bay around the vents is corrosive to calcium carbonate; the north shore has a gradient in seawater carbonate chemistry that is well suited to studies of the effects of long-term increases in CO2 levels. This shoreline lacks toxic compounds (such as H2S) and has a gradient in carbonate saturation states. Copyright © 2013 Elsevier Ltd. All rights reserved.
Comparison of CyTOF assays across sites: Results of a six-center pilot study.
Leipold, Michael D; Obermoser, Gerlinde; Fenwick, Craig; Kleinstuber, Katja; Rashidi, Narges; McNevin, John P; Nau, Allison N; Wagar, Lisa E; Rozot, Virginie; Davis, Mark M; DeRosa, Stephen; Pantaleo, Giuseppe; Scriba, Thomas J; Walker, Bruce D; Olsen, Lars R; Maecker, Holden T
2018-02-01
For more than five years, high-dimensional mass cytometry has been employed to study immunology. However, these studies have typically been performed in one laboratory on one or few instruments. We present the results of a six-center study using healthy control human peripheral blood mononuclear cells (PBMCs) and commercially available reagents to test the intra-site and inter-site variation of mass cytometers and operators. We used prestained controls generated by the primary center as a reference to compare against samples stained at each individual center. Data were analyzed at the primary center, including investigating the effects of two normalization methods. All six sites performed similarly, with CVs for both Frequency of Parent and median signal intensity (MSI) values<30%. Increased background was seen when using the premixed antibody cocktail aliquots at each site, suggesting that cocktails are best made fresh. Both normalization methods tested performed adequately for normalizing MSI values between centers. Clustering algorithms revealed slight differences between the prestained and the sites-stained samples, due mostly to the increased background of a few antibodies. Therefore, we believe that multicenter mass cytometry assays are feasible. Copyright © 2017 The Author(s). Published by Elsevier B.V. All rights reserved.
Comparison of quantitative and qualitative tests for glucose-6-phosphate dehydrogenase deficiency.
LaRue, Nicole; Kahn, Maria; Murray, Marjorie; Leader, Brandon T; Bansil, Pooja; McGray, Sarah; Kalnoky, Michael; Zhang, Hao; Huang, Huiqiang; Jiang, Hui; Domingo, Gonzalo J
2014-10-01
A barrier to eliminating Plasmodium vivax malaria is inadequate treatment of infected patients. 8-Aminoquinoline-based drugs clear the parasite; however, people with glucose-6-phosphate dehydrogenase (G6PD) deficiency are at risk for hemolysis from these drugs. Understanding the performance of G6PD deficiency tests is critical for patient safety. Two quantitative assays and two qualitative tests were evaluated. The comparison of quantitative assays gave a Pearson correlation coefficient of 0.7585 with significant difference in mean G6PD activity, highlighting the need to adhere to a single reference assay. Both qualitative tests had high sensitivity and negative predictive value at a cutoff G6PD value of 40% of normal activity if interpreted conservatively and performed under laboratory conditions. The performance of both tests dropped at a cutoff level of 45%. Cytochemical staining of specimens confirmed that heterozygous females with > 50% G6PD-deficient cells can seem normal by phenotypic tests. © The American Society of Tropical Medicine and Hygiene.
Aerial photographic water color variations from pollution in the James River
NASA Technical Reports Server (NTRS)
Bressette, W. E.
1978-01-01
A photographic flight was made over the James River on May 17, 1977. The data show that, in general, James River water has very high sunlight reflectance. In the Bailey Bay area this reflectance is drastically reduced. Also shown is a technique for normalizing off-axis variations in radiance film exposure from camera falloff and uneven sunlight conditions to the nadir value. After data normalization, a spectral analysis is performed that identifies Bailey Creek water in James River water. The spectral results when compared with laboratory spectrometer data indicate that reflectance from James River water is dominated by suspended matter, while the substance most likely responsible for reduced reflectance in Bailey Creek water is dissolved organic carbon.
McMahon, Adrienne
2016-01-01
The main objective of the AOAC Stakeholder Panel on Infant Formula and Adult Nutritionals (SPIFAN) project is to establish international consensus methods for infant formula and adult nutritionals, which will benefit intermarket supply and dispute resolution. A collaborative study was conducted on AOAC First Action Method 2012.10 Simultaneous Determination of 13-cis and All-trans Vitamin A Palmitate (Retinyl Palmitate), Vitamin A Acetate (Retinyl Acetate), and Total Vitamin E (α-Tocopherol and D-α-tocopherol acetate) in Infant Formula and Adult Nutritionals by Normal-Phase HPLC. Fifteen laboratories from 11 countries participated in an interlaboratory study to determine 13-cis and all-trans vitamin A palmitate (retinyl palmitate), vitamin A acetate (retinyl acetate), and total vitamin E (α-tocopherol and D-α-tocopherol acetate) in infant formula and adult nutritionals by normal-phase HPLC and all laboratories returned valid data. Eighteen test portions of nine blind duplicates of a variety of infant formula and adult nutritional products were used in the study. The matrixes included milk-based and soy-based hydrolyzed protein as well as a low fat product. Each of the samples was prepared fresh and analyzed in singlicate. As the number of samples exceeded the recommended number to be prepared in a single day, analysis took place over 2 days running 12 samples on day one and 10 samples on day two. The reference standard stock was prepared once and the six-point curve diluted freshly on each day. Results obtained from all 15 laboratories are reported. The RSDR for total vitamin A (palmitate or acetate) ranged from 6.51 to 22.61% and HorRat values ranged from 0.33 to 1.25. The RSDR for total vitamin E (as tocopherol equivalents) ranged from 3.84 to 10.78% and HorRat values ranged from 0.27 to 1.04. Except for an adult low fat matrix which generated reproducibility RSD >40% for some isomers, most SPIFAN matrixes gave results within the acceptance criteria of <16% RSD as stated in the respective Standard Method Performance Requirements.
Detection of human papillomavirus DNA in patients referred to a family practice colposcopy clinic.
Holman, J R
1996-01-01
Human papillomavirus (HPV) is strongly implicated in the pathogenesis of cervical neoplasia. The ability of a commercially available kit (Virapap/Viratype) to detect evidence of HPV is compared with cervical cytology, colposcopy, and directed biopsies. During a period of 16 months, cervical samples from 241 consecutive new patients referred for a colposcopy examination were obtained for HPV-DNA hybridization typing according to the kit instructions. Samples were sent to a reference laboratory for testing. The results were compared with results of the colposcopy examination, cervical cytology, and directed cervical biopsy samples processed and evaluated by our hospital laboratory. HPV DNA was detected in 27 of 107 patients who had abnormal colposcopy findings for a sensitivity of 25 +/- 7.5 percent at the 90 percent confidence interval. One of 134 patients with normal findings was positive for a specificity of 99 +/- 5 percent at the 95 percent confidence interval. Based on a 75 percent probability of HPV in the population, the positive predictive value was 99 percent and the negative predictive value 30 percent. With the low negative predictive value and sensitivity, HPV-DNA testing by this commercial kit is not an adequate tool for screening HPV in this population.
Reference values for clinical laboratory parameters in young adults in Maputo, Mozambique.
Tembe, Nelson; Joaquim, Orvalho; Alfai, Eunice; Sitoe, Nádia; Viegas, Edna; Macovela, Eulalia; Gonçalves, Emilia; Osman, Nafissa; Andersson, Sören; Jani, Ilesh; Nilsson, Charlotta
2014-01-01
Clinical laboratory reference values from North American and European populations are currently used in most Africans countries due to the absence of locally derived reference ranges, despite previous studies reporting significant differences between populations. Our aim was to define reference ranges for both genders in 18 to 24 year-old Mozambicans in preparation for clinical vaccine trials. A cross-sectional study including 257 volunteers (102 males and 155 females) between 18 and 24 years was performedat a youth clinic in Maputo, Mozambique. All volunteers were clinically healthy and human immunodeficiency virus, Hepatitis B virus and syphilis negative.Median and 95% reference ranges were calculated for immunological, hematological and chemistry parameters. Ranges were compared with those reported based on populations in other African countries and the US. The impact of applying US NIH Division of AIDS (DAIDS) toxicity tables was assessed. The immunology ranges were comparable to those reported for the US and western Kenya.There were significant gender differences in CD4+ T cell values 713 cells/µL in males versus 824 cells/µL in females (p<0.0001). Hematologic values differed from the US values but were similar to reports of populations in western Kenya and Uganda. The lower and upper limits of the ranges for hemoglobin, hematocrit, red blood cells, white blood cells and lymphocytes were somewhat lower than those from these African countries. The chemistry values were comparable to US values, with few exceptions. The upper limits for ALT, AST, bilirubin, cholesterol and triglycerides were higher than those from the US. DAIDStables for adverse events predicted 297 adverse events and 159 (62%) of the volunteers would have been excluded. This study is the first to determine normal laboratory parameters in Mozambique. Our results underscore the necessity of establishing region-specific clinical reference ranges for proper patient management and safe conduct of clinical trials.
Haeckel, Rainer; Wosniok, Werner
2010-10-01
The distribution of many quantities in laboratory medicine are considered to be Gaussian if they are symmetric, although, theoretically, a Gaussian distribution is not plausible for quantities that can attain only non-negative values. If a distribution is skewed, further specification of the type is required, which may be difficult to provide. Skewed (non-Gaussian) distributions found in clinical chemistry usually show only moderately large positive skewness (e.g., log-normal- and χ(2) distribution). The degree of skewness depends on the magnitude of the empirical biological variation (CV(e)), as demonstrated using the log-normal distribution. A Gaussian distribution with a small CV(e) (e.g., for plasma sodium) is very similar to a log-normal distribution with the same CV(e). In contrast, a relatively large CV(e) (e.g., plasma aspartate aminotransferase) leads to distinct differences between a Gaussian and a log-normal distribution. If the type of an empirical distribution is unknown, it is proposed that a log-normal distribution be assumed in such cases. This avoids distributional assumptions that are not plausible and does not contradict the observation that distributions with small biological variation look very similar to a Gaussian distribution.
Monitoring of anticoagulant therapy in heart disease: considerations for the current assays.
Boroumand, Mohammadali; Goodarzynejad, Hamidreza
2010-01-01
Clinicians should be aware of new developments to familiarize themselves with pharmacokinetic and pharmacodynamic characteristics of new anticoagulant agents to appropriately and safely use them. For the moment, cardiologists and other clinicians also require to master currently available drugs, realizing the mechanism of action, side effects, and laboratory monitoring to measure their anticoagulant effects. Warfarin and heparin have narrow therapeutic window with high inter- and intra-patient variability, thereby the use of either drug needs careful laboratory monitoring and dose adjustment to ensure proper antithrombotic protection while minimizing the bleeding risk. The prothrombin time (PT) and the activated partial thromboplastin time (aPTT) are laboratory tests commonly used to monitor warfarin and heparin, respectively. These two tests depend highly on the combination of reagent and instrument utilized. Results for a single specimen tested in different laboratories are variable; this is mostly attributable to the specific reagents and to a much lesser degree to the instrument used. The PT stands alone as the single coagulation test that has undergone the most extensive attempt at assay standardization. The international normalized ratio (INR) was introduced to "normalize" all PT reagents to a World Health Organization (WHO) reference thromboplastin preparation standard, such that a PT measured anywhere in the world would result in an INR value similar to that which would have been achieved had the WHO reference thromboplastin been utilized. However, INRs are reproducible between laboratories for only those patients who are stably anticoagulated with vitamin K antagonists (VKAs) (i.e., at least 6 weeks of VKA therapy), and are not reliable or reproducible between laboratories for patients for whom VKA therapy has recently been started or any other clinical conditions associated with a prolonged PT such as liver disease, disseminated intravascular coagulation, and congenital factor deficiencies. In contrast to marked progress in the standardization of PT reagents for INR reporting, no standardization system has been globally adopted for standardization of PTT reagents. Recently College of American Pathologists recommend that individual laboratories establish their own therapeutic range by using aPTT values calibrated against accepted therapeutic unfractionated heparin (UFH) levels calibrated against accepted therapeutic UFH levels performing anti-Xa test (which is the most accurate assay for monitoring UFH therapy).Herein, we review recent data on the monitoring of conventional anticoagulant agents. Marked interlaboratory variability still exists for PT, INR, and PTT tests. Further research should be focused on improving the standardization and calibration of these assays.
Zikmund-Fisher, Brian J; Scherer, Aaron M; Witteman, Holly O; Solomon, Jacob B; Exe, Nicole L; Fagerlin, Angela
2018-03-26
Patient-facing displays of laboratory test results typically provide patients with one reference point (the "standard range"). To test the effect of including an additional harm anchor reference point in visual displays of laboratory test results, which indicates how far outside of the standard range values would need to be in order to suggest substantial patient risk. Using a demographically diverse, online sample, we compared the reactions of 1618 adults in the United States who viewed visual line displays that included both standard range and harm anchor reference points ("Many doctors are not concerned until here") to displays that included either (1) only a standard range, (2) standard range plus evaluative categories (eg, "borderline high"), or (3) a color gradient showing degree of deviation from the standard range. Providing the harm anchor reference point significantly reduced perceived urgency of close-to-normal alanine aminotransferase and creatinine results (P values <.001) but not generally for platelet count results. Notably, display type did not significantly alter perceptions of more extreme results in potentially harmful ranges. Harm anchors also substantially reduced the number of participants who wanted to contact their doctor urgently or go to the hospital about these test results. Presenting patients with evaluative cues regarding when test results become clinically concerning can reduce the perceived urgency of out-of-range results that do not require immediate clinical action. ©Brian J Zikmund-Fisher, Aaron M Scherer, Holly O Witteman, Jacob B Solomon, Nicole L Exe, Angela Fagerlin. Originally published in the Journal of Medical Internet Research (http://www.jmir.org), 26.03.2018.
NASA Technical Reports Server (NTRS)
SHARDANAND; Rao, A. D. P.
1977-01-01
The laboratory measurements of absolute Rayleigh scattering cross sections as a function wavelength are reported for gas molecules He, Ne, Ar, N2, H2, O2, CO2, CH4 and for vapors of most commonly used freons CCl2F2, CBrF3, CF4, and CHClf2. These cross sections are determined from the measurements of photon scattering at an angle of 54 deg 44 min which yield the absolute values independent of the value of normal depolarization ratios. The present results show that in the spectral range 6943-3638A deg, the values of the Rayleigh scattering cross section can be extrapolated from one wavelength to the other using 1/lambda (4) law without knowing the values of the polarizabilities. However, such an extrapolation can not be done in the region of shorter wavelengths.
The effect of blood cell count on coronary flow in patients with coronary slow flow phenomenon.
Soylu, Korhan; Gulel, Okan; Yucel, Huriye; Yuksel, Serkan; Aksan, Gokhan; Soylu, Ayşegül İdil; Demircan, Sabri; Yılmaz, Ozcan; Sahin, Mahmut
2014-09-01
The coronary slow flow phenomenon (CSFP) is a coronary artery disease with a benign course, but its pathological mechanisms are not yet fully understood.The purpose of this controlled study was to investigate the cellular content of blood in patients diagnosed with CSFP and the relationship of this with coronary flow rates. Selective coronary angiographies of 3368 patients were analyzed to assess Thrombolysis in Myocardial Infarction (TIMI) frame count (TFC) values. Seventy eight of them had CSFP, and their demographic and laboratory findings were compared with 61 patients with normal coronary flow. Patients' demographic characteristics were similar in both groups. Mean corrected TFC (cTFC) values were significantly elevated in CSFP patients (p<0.001). Furthermore, hematocrit and hemoglobin values, and eosinophil and basophil counts of the CSFP patients were significantly elevated compared to the values obtained in the control group (p=0.005, p=0.047, p=0.001 and p=0.002, respectively). The increase observed in hematocrit and eosinophil levels showed significant correlations with increased TFC values (r=0.288 and r=0.217, respectively). Significant changes have been observed in the cellular composition of blood in patients diagnosed with CSFP as compared to the patients with normal coronary blood flow. The increases in hematocrit levels and in the eosinophil and basophil counts may have direct or indirect effects on the rate of coronary blood flow.
Kawai, Y; Nagai, Y; Ogawa, E; Kondo, H
2017-04-01
To provide target values for the manufacturers' survey of the Japanese Society for Laboratory Hematology (JSLH), accurate standard data from healthy volunteers were needed for the five-part differential leukocyte count. To obtain such data, JSLH required an antibody panel that achieved high specificity (particularly for mononuclear cells) using simple gating procedures. We developed a flow cytometric method for determining the differential leukocyte count (JSLH-Diff) and validated it by comparison with the flow cytometric differential leukocyte count of the International Council for Standardization in Haematology (ICSH-Diff) and the manual differential count obtained by microscopy (Manual-Diff). First, the reference laboratory performed an imprecision study of JSLH-Diff and ICSH-Diff, as well as performing comparison among JSLH-Diff, Manual-Diff, and ICSH-Diff. Then two reference laboratories and seven participating laboratories performed imprecision and accuracy studies of JSLH-Diff, Manual-Diff, and ICSH-Diff. Simultaneously, six manufacturers' laboratories provided their own representative values by using automated hematology analyzers. The precision of both JSLH-Diff and ICSH-Diff methods was adequate. Comparison by the reference laboratory showed that all correlation coefficients, slopes and intercepts obtained by the JSLH-Diff, ICSH-Diff, and Manual-Diff methods conformed to the criteria. When the imprecision and accuracy of JSLH-Diff were assessed at seven laboratories, the CV% for lymphocytes, neutrophils, monocytes, eosinophils, and basophils was 0.5~0.9%, 0.3~0.7%, 1.7~2.6%, 3.0~7.9%, and 3.8~10.4%, respectively. More than 99% of CD45 positive leukocytes were identified as normal leukocytes by JSLH-Diff. When JSLH-Diff method were validated by comparison with Manual-Diff and ICSH-Diff, JSLH-Diff showed good performance as a reference method. © 2016 John Wiley & Sons Ltd.
Škrbić, Biljana; Héberger, Károly; Durišić-Mladenović, Nataša
2013-10-01
Sum of ranking differences (SRD) was applied for comparing multianalyte results obtained by several analytical methods used in one or in different laboratories, i.e., for ranking the overall performances of the methods (or laboratories) in simultaneous determination of the same set of analytes. The data sets for testing of the SRD applicability contained the results reported during one of the proficiency tests (PTs) organized by EU Reference Laboratory for Polycyclic Aromatic Hydrocarbons (EU-RL-PAH). In this way, the SRD was also tested as a discriminant method alternative to existing average performance scores used to compare mutlianalyte PT results. SRD should be used along with the z scores--the most commonly used PT performance statistics. SRD was further developed to handle the same rankings (ties) among laboratories. Two benchmark concentration series were selected as reference: (a) the assigned PAH concentrations (determined precisely beforehand by the EU-RL-PAH) and (b) the averages of all individual PAH concentrations determined by each laboratory. Ranking relative to the assigned values and also to the average (or median) values pointed to the laboratories with the most extreme results, as well as revealed groups of laboratories with similar overall performances. SRD reveals differences between methods or laboratories even if classical test(s) cannot. The ranking was validated using comparison of ranks by random numbers (a randomization test) and using seven folds cross-validation, which highlighted the similarities among the (methods used in) laboratories. Principal component analysis and hierarchical cluster analysis justified the findings based on SRD ranking/grouping. If the PAH-concentrations are row-scaled, (i.e., z scores are analyzed as input for ranking) SRD can still be used for checking the normality of errors. Moreover, cross-validation of SRD on z scores groups the laboratories similarly. The SRD technique is general in nature, i.e., it can be applied to any experimental problem in which multianalyte results obtained either by several analytical procedures, analysts, instruments, or laboratories need to be compared.
Evaluation of selected clinical and diagnostic parameters in girls with anorexia nervosa (I).
Nogal, Paweł; Pniewska-Siark, Barbara; Lewiński, Andrzej
2008-08-01
Body weight loss in patients with anorexia nervosa (AN) is accompanied by a number of hormonal and metabolic disorders. The scope and intensity of these disorders may have a considerable influence on the prognosis in this disease. The goal of the study was an evaluation of selected diagnostic examinations in comparison with clinical data of female patients with AN. Retrospective studies involved eighty-seven (87) patients with AN. On therapy commencement, routine laboratory tests (full blood cell count, serum concentrations of sodium, potassium, glucose, cholesterol, triglycerides, total calcium, phosphates, total protein and the urea) and hormonal tests (TSH, TSH, FT4, FT3, E2, T, cortisol measured at 8(00), 17(00) and 24(00), LH and FSH in stimulation test with GnRH) were performed in each patient. Correlations were determined between clinical data and the measured hormone concentrations. In the studied girls, the mean values of routine laboratory tests, performed at the beginning of the therapy, were within the normal ranges (except hypernatremia). The mean concentrations of LH, FSH and FT4 were below reference values; the mean concentration of cortisol considerably exceeded the standard range. Statistically significant relations were demonstrated between BMI values and the concentrations of LH, E2 and cortisol. Body weigh loss is not significantly reflected by abnormal results of routinely performed laboratory tests. Hypogonadotropic hypogonadism and hypercortisolemia are the most characteristic hormonal symptoms in girls with AN.
Ruha, Anne-Michelle; Curry, Steven C; Beuhler, Michael; Katz, Ken; Brooks, Daniel E; Graeme, Kimberlie A; Wallace, Kevin; Gerkin, Richard; Lovecchio, Frank; Wax, Paul; Selden, Brad
2002-06-01
We describe our postmarketing experience with patients receiving Crotalidae polyvalent immune Fab (CroFab; FabAV) antivenom for treatment of rattlesnake envenomation. The charts of 28 patients admitted between March 1 and September 9, 2001, with rattlesnake envenomation and treated with FabAV were reviewed for demographic information, time until antivenom treatment, laboratory findings, evidence of hypersensitivity reaction, length of hospital stay, and readmission to the hospital. All patients had swelling, 20 patients had elevated prothrombin times (>14 seconds), 12 patients had low fibrinogen levels (<170 mg/dL), and 6 patients had thrombocytopenia (platelet count <120,000/mm(3)) on presentation. The total dose of FabAV ranged from 10 to 47 vials per patient. Hypofibrinogenemia was resistant to FabAV in some patients. On follow-up, recurrence of coagulopathy was detected in 3 patients, and recurrence of thrombocytopenia was detected in 1 patient. Two patients demonstrated delayed-onset severe thrombocytopenia. Recurrence or delayed-onset toxicity might have been underestimated because of incomplete follow-up in some patients. No acute hypersensitivity reactions occurred. Two patients reported mild symptoms of possible serum sickness on follow-up. FabAV effectively controlled the effects of envenomation; however, initial control of coagulopathy was difficult to achieve in some cases, and recurrence or delayed-onset hematotoxicity was common. When initially managing hematotoxicity, a trend toward normalization of laboratory values might be a more reasonable end point for FabAV treatment than attainment of normal reference values in nonbleeding patients.
Electrophoretic purification of cells in space - Evaluation of results from STS-3
NASA Technical Reports Server (NTRS)
Sarnoff, B. E.; Kunze, M. E.; Todd, P.
1983-01-01
The procedure and results of Electrophoresis Equipment Verification Test, designed to examine electrophoretic behavior of animal cells is suspension more concentrated than possible on earth and flown on the Shuttle flight STS-3, were discussed. Ground-based laboratory values of electrophoretic mobilities of a mixture of human and rabbit aldehyde-fixed red blood cells (RBC) were compared with those recorded at 11 minute intervals on the Shuttle STS-3. RBC migration and separation observed through photographic records were not as expected. However, cell mobilities and migrating band profiles were consistent with the results of laboratory simulation experiments. It was concluded that zero G electrophoresis of very high concentrations (1 x 10 to the 9th) is possible and similar to electrophoresis of normal cell concentrations on earth.
[Multisite validation of CDT measurement by the %CDT TIA and the Tina Quant %CDT kits].
Boehrer, J L; Cano, Y; Capolaghi, B; Desch, G; Dosbaa, I; Estepa, L; Hennache, B; Schellenberg, F
2007-01-01
The measurement of CDT (Carbohydrate Deficient Transferrin) is an essential biological tool in the diagnosis and follow-up of alcohol abuse. It is also employed as a marker of abstinence for the restitution of driving licences. However, the precision of measurement, and the between laboratory homogeneity of the results are still discussed. The ion exchange followed by immunodetermination of CDT is available in two products, the Tina Quant %CDT (Roche, Mannheim, Germany) and the %CDT TIA (Bio-Rad, Hercules, United States). This multicentre study was undertaken: 1) to evaluate the analytical characteristics of these kits and the homogeneity of the results from one laboratory to another, independently of the method used, 2) to validate the differences between the proposed normal values of both kits, 3) to study the possibility of using commercial control sera as external quality control. Four analytical systems were included in the study (Roche Modular/Hitachi 717, Beckman Coulter Immage and LX20, Dade Behring BNII). Determinations were carried out on pools of sera, commercial control sera, kit controls, and 30 serums of patients. These latter were also analyzed in capillary electrophoresis in order to establish correlations between the techniques. The calibrations were stable over one 2 weeks period. The repeatability of measurements spread out from 3,1% to 24,7%, for a mean value lower than 10%. The commercial control sera provided reliable results, with values adapted to a routine quality control use. The results of the Bio-Rad applications were lower by approximately 20% than those of the Roche application, which justifies the difference of the normal values (2,6% versus 3%), and an identical classification of the patients in at least 27 of the 30 samples. We conclude that the analytical quality of the compared techniques, even if it could be improved, is sufficient to guarantee a good reliability of the results. An external quality control could be proposed by using the control sera that we tested.
Meng, Wei-Dong; Sun, Shao-Jun; Yang, Jie; Chu, Rui-Xue; Tu, Wenjun; Liu, Qiang
2017-03-01
The aim of our study was to illuminate the potential role of brain-derived neurotrophic factor (BDNF) in autism spectrum disorder (ASD). We measured the circulating levels of BDNF in serum and BDNF gene (Val66Met) polymorphisms, in which two indicators were then compared between ASD and normal controls. A total of 82 drug-naïve ASD children and 82 age- and gender-matched normal controls were enrolled in the study. Their serum BDNF levels were detected by the ELISA. BDNF Val66Met polymorphism genotyping was conducted as according to the laboratory's standard protocol in laboratory. The ASD severity assessment was mainly determined by the score of the Childhood Autism Rating Scale (CARS). ELISA assay showed that the mean serum BDNF level of children with ASD was significantly (P < 0.0001) higher than that of the control cases (17.75 ± 5.43 vs. 11.49 ± 2.85 ng/ml; t = 9.236). Besides, the serum BDNF levels and CARS scores (P < 0.0001) were positively related. And, the BDNF genotyping results showed that there was no difference between the ASD cases and the control. Among the children with ASD, the mean serum BDNF level of Met/Met group was lower than other groups. According to the ROC curve generated from our clinical data, the optimal cutoff value of serum BDNF levels, an indicator for diagnosis of ASD, was projected to be 12.50 ng/ml. Thus, it yielded a corresponding sensitivity of 81.7 % and the specificity of 66.9 %. Accordingly, area value under the curve was 0.836 (95 % CI, 0.774-0.897); the positive predictive value (PPV) and the negative predictive value (NPV) were 70.1 and 79.1 %, respectively. These results suggested that rather than Val66Met polymorphism, BDNF was more possible to impact the pathogenesis of ASD.
Yamakado, Minoru; Ichihara, Kiyoshi; Matsumoto, Yoshiyuki; Ishikawa, Yoshiki; Kato, Kiminori; Komatsubara, Yusuke; Takaya, Norihide; Tomita, Shohken; Kawano, Reo; Takada, Keisuke; Watanabe, Kiyoaki
2015-07-20
With nationwide standardization of laboratory tests among institutions for health screening in Japan, common reference intervals (RIs) were derived from records of 1,500,000 health check attendees. Targets were 20 basic laboratory tests including body mass index (BMI) and systolic and diastolic blood pressures (SBP, DBP). Individuals fulfilling the following strict criteria were chosen: SBP<130, DBP<85mmHg, BMI<25kg/m(2), non-smoking, ethanol consumption<20g/day and under no mediation with no remarkable current/past illnesses. The latent abnormal values exclusion (LAVE) method was applied to ensure fully normal results. RIs were derived by parametric method using modified Box-Cox power transformation. Among all attendees, 23% fulfilled the criteria. Application of the LAVE method further reduced the dataset by 40%-50%. Age-related charts of test results differed greatly between genders in almost all tests. Comparison of derived RIs with clinical decision limits (CDLs) revealed that the upper limits of RIs differed from CDLs according to gender and age. Implementation of gender and age-specific RIs derived from individuals with fully normal health attributes will (1) enable appropriate interpretation of test results in health screening and (2) promote judicious application of CDLs for therapeutic intervention, taking into account gender, age and other health attributes. Copyright © 2015 Elsevier B.V. All rights reserved.
Laboratory signs of aspirin response in haemodialysis patients.
Kilickesmez, Kadriye O; Kocas, Cuneyt; Okcun, Baris; Abaci, Okay; Kaya, Aysem; Arat, Alev; Gorcin, Bilal; Gurmen, Tevfik
2011-09-01
Aspirin is effective in the secondary prevention and high-risk primary prevention of cardiovascular events. However, clinical and laboratory evidence demonstrates diminished or no response to aspirin in some patients. This study was designed to assess aspirin response in haemodialysis patients. We prospectively enrolled 78 haemodialysis patients (28 female; 58.4 ± 12.6 years old) and 79 patients (29 female; 58.4 ± 10.6 years old) with normal renal function (glomerular filtration rate (GFR) >60 mL/min/1.73 m(2)). All subjects in both the haemodialysis patient group and the control group were taking aspirin (80-300 mg) for at least 30 days and were not taking other antiplatelet agents. Platelet function was assessed by arachidonic acid-induced aggregometry with a Multiplate analyser (Dynabyte Medical, Munich, Germany). Multiplate electrode aggregometry values below 300 AU were applied as a cut-off for response to aspirin. Aspirin non-response was two-fold more prevalent in haemodialysis patients (42.3%) than in patients with normal renal function (21.5%), and this difference was statistically significant (p = 0.005). The two groups were similar in terms of sex, age, tobacco use, the presence of diabetes mellitus, and platelet count. The frequency of aspirin non-response as defined in this study was higher in haemodialysis patients than in patients with normal renal function. However, larger subsets of patients are needed to confirm the present study.
A semi-micromethod for determination of oxalate in human plasma.
Porowski, Tadeusz; Gałasiński, Władysław
2003-01-01
An enzymatic semi-micromethod for oxalate determination in human plasma was elaborated. The principle of the method depends on the oxalate isolation from deproteinized plasma, following determination by the calorimetric oxalate oxidase-peroxidase-indamine system. This method protects against internal oxalate losses and excludes an interference of contaminations. Results, obtained by this method, were reliable and ideally suited for use as real normal values (less than or equal to 6 microM) of oxalate content in the plasma of healthy individuals. The elaborated method, which can assay plasma oxalate accurately in normal individuals as well as in hyperoxalemic conditions is superior to those previously used. The procedure of semi-micromethod does not require expensive equipments and apparatus: it is simple and easy to perform in every laboratory and takes little time.
Correlation to FVIII:C in Two Thrombin Generation Tests: TGA-CAT and INNOVANCE ETP.
Ljungkvist, Marcus; Berndtsson, Maria; Holmström, Margareta; Mikovic, Danijela; Elezovic, Ivo; Antovic, Jovan P; Zetterberg, Eva; Berntorp, Erik
2017-01-01
Several thrombin-generation tests are available, but few have been directly compared. Our primary aim was to investigate the correlation of two thrombin generation tests, thrombin generation assay-calibrated automated thrombogram (TGA-CAT) and INNOVANCE ETP, to factor VIII levels (FVIII:C) in a group of patients with hemophilia A. The secondary aim was to investigate inter-laboratory variation for the TGA-CAT method. Blood samples were taken from 45 patients with mild, moderate and severe hemophilia A. The TGA-CAT method was performed at both centers while the INNOVANCE ETP was only performed at the Stockholm center. Correlation between parameters was evaluated using Spearman's rank correlation test. For determination of the TGA-CAT inter-laboratory variability, Bland-Altman plots were used. The correlation for the INNOVANCE ETP and TGA-CAT methods with FVIII:C in persons with hemophilia (PWH) was r=0.701 and r=0.734 respectively.The correlation between the two methods was r=0.546.When dividing the study material into disease severity groups (mild, moderate and severe) based on FVIII levels, both methods fail to discriminate between them.The variability of the TGA-CAT results performed at the two centers was reduced after normalization; before normalization, 29% of values showed less than ±10% difference while after normalization the number increased to 41%. Both methods correlate in an equal manner to FVIII:C in PWH but show a poor correlation with each other. The level of agreement for the TGA-CAT method was poor though slightly improved after normalization of data. Further improvement of standardization of these methods is warranted.
Regional reference values of thyroid gland volume in Turkish Adults.
Şahin, Ertan; Elboğa, Umut; Kalender, Ebuzer
2015-01-01
It is important to know the size of the thyroid gland, and its normal value may vary among different geographic regions. In this study, we aimed to establish reference ranges for thyroid volume in euthyroid adults and to compare these results with the literature data. Between June 2011 and June 2012,461 patients with normal laboratory results (serum TSH, anti-TG, anti-TPO antibodies and urine iodine level) that underwent thyroid gland ultrasound examination were retrospectively analyzed.Two hundred and 92 patients were females and 169 were males; the age range was 18-61 years with mean age 30.84±9.97 years. Length, breadth and thickness were measured, and the volume of each lobe was estimated using the ellipsoid formula. The overall mean thyroid volume in all patients who were examined was 12.98±2.53 mL. The mean thyroid volume in females and males was 12.09±2.05 mL and 14.53±2.55, respectively (p<0.05). The right thyroid lobe volume was greater than the left in all patients of both sexes. In addition, the study establishes a significant correlation between the thyroid volume and height, weight and body surface area of the subjects of both sexes (p<0.05). In the light of our findings we can provide reference values in order to evaluate patients who have thyroid hyperplasia or who are considered as normal. We consider that further studies are necessary to establish national references thyroid volume for each country.
Trabado, Séverine; Al-Salameh, Abdallah; Croixmarie, Vincent; Masson, Perrine; Corruble, Emmanuelle; Fève, Bruno; Colle, Romain; Ripoll, Laurent; Walther, Bernard; Boursier-Neyret, Claire; Werner, Erwan; Becquemont, Laurent; Chanson, Philippe
2017-01-01
Metabolomic approaches are increasingly used to identify new disease biomarkers, yet normal values of many plasma metabolites remain poorly defined. The aim of this study was to define the "normal" metabolome in healthy volunteers. We included 800 French volunteers aged between 18 and 86, equally distributed according to sex, free of any medication and considered healthy on the basis of their medical history, clinical examination and standard laboratory tests. We quantified 185 plasma metabolites, including amino acids, biogenic amines, acylcarnitines, phosphatidylcholines, sphingomyelins and hexose, using tandem mass spectrometry with the Biocrates AbsoluteIDQ p180 kit. Principal components analysis was applied to identify the main factors responsible for metabolome variability and orthogonal projection to latent structures analysis was employed to confirm the observed patterns and identify pattern-related metabolites. We established a plasma metabolite reference dataset for 144/185 metabolites. Total blood cholesterol, gender and age were identified as the principal factors explaining metabolome variability. High total blood cholesterol levels were associated with higher plasma sphingomyelins and phosphatidylcholines concentrations. Compared to women, men had higher concentrations of creatinine, branched-chain amino acids and lysophosphatidylcholines, and lower concentrations of sphingomyelins and phosphatidylcholines. Elderly healthy subjects had higher sphingomyelins and phosphatidylcholines plasma levels than young subjects. We established reference human metabolome values in a large and well-defined population of French healthy volunteers. This study provides an essential baseline for defining the "normal" metabolome and its main sources of variation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Basore, Paul; Chung, Donald; Buonassisi, Tonio
2015-06-14
The past decade’s record of growth in the photovoltaic manufacturing industry indicates that global investment in manufacturing capacity for photovoltaic modules tends to increase in proportion to the size of the industry. The slope of this proportionality determines how fast the industry will grow in the future. Two key parameters determine this slope. One is the annual global investment in manufacturing capacity normalized to the manufacturing capacity for the previous year (capacity-normalized capital investment rate, CapIR, units $/W). The other is how much capital investment is required for each watt of annual manufacturing capacity, normalized to the service life ofmore » the assets (capacity-normalized capital demand rate, CapDR, units $/W). If these two parameters remain unchanged from the values they have held for the past few years, global manufacturing capacity will peak in the next few years and then decline. However, it only takes a small improvement in CapIR to ensure future growth in photovoltaics. Any accompanying improvement in CapDR will accelerate that growth.« less
NASA Astrophysics Data System (ADS)
Khachatryan, V.; Sirunyan, A. M.; Tumasyan, A.; Adam, W.; Asilar, E.; Bergauer, T.; Brandstetter, J.; Brondolin, E.; Dragicevic, M.; Erö, J.; Flechl, M.; Friedl, M.; Frühwirth, R.; Ghete, V. M.; Hartl, C.; Hörmann, N.; Hrubec, J.; Jeitler, M.; Knünz, V.; König, A.; Krammer, M.; Krätschmer, I.; Liko, D.; Matsushita, T.; Mikulec, I.; Rabady, D.; Rad, N.; Rahbaran, B.; Rohringer, H.; Schieck, J.; Schöfbeck, R.; Strauss, J.; Treberer-Treberspurg, W.; Waltenberger, W.; Wulz, C.-E.; Mossolov, V.; Shumeiko, N.; Suarez Gonzalez, J.; Alderweireldt, S.; Cornelis, T.; De Wolf, E. A.; Janssen, X.; Knutsson, A.; Lauwers, J.; Luyckx, S.; Van De Klundert, M.; Van Haevermaet, H.; Van Mechelen, P.; Van Remortel, N.; Van Spilbeeck, A.; Abu Zeid, S.; Blekman, F.; D'Hondt, J.; Daci, N.; De Bruyn, I.; Deroover, K.; Heracleous, N.; Keaveney, J.; Lowette, S.; Moreels, L.; Olbrechts, A.; Python, Q.; Strom, D.; Tavernier, S.; Van Doninck, W.; Van Mulders, P.; Van Onsem, G. P.; Van Parijs, I.; Barria, P.; Brun, H.; Caillol, C.; Clerbaux, B.; De Lentdecker, G.; Fasanella, G.; Favart, L.; Goldouzian, R.; Grebenyuk, A.; Karapostoli, G.; Lenzi, T.; Léonard, A.; Maerschalk, T.; Marinov, A.; Pernié, L.; Randle-conde, A.; Seva, T.; Vander Velde, C.; Vanlaer, P.; Yonamine, R.; Zenoni, F.; Zhang, F.; Beernaert, K.; Benucci, L.; Cimmino, A.; Crucy, S.; Dobur, D.; Fagot, A.; Garcia, G.; Gul, M.; Mccartin, J.; Ocampo Rios, A. A.; Poyraz, D.; Ryckbosch, D.; Salva, S.; Sigamani, M.; Tytgat, M.; Van Driessche, W.; Yazgan, E.; Zaganidis, N.; Basegmez, S.; Beluffi, C.; Bondu, O.; Brochet, S.; Bruno, G.; Caudron, A.; Ceard, L.; Delaere, C.; Favart, D.; Forthomme, L.; Giammanco, A.; Jafari, A.; Jez, P.; Komm, M.; Lemaitre, V.; Mertens, A.; Musich, M.; Nuttens, C.; Perrini, L.; Piotrzkowski, K.; Popov, A.; Quertenmont, L.; Selvaggi, M.; Vidal Marono, M.; Beliy, N.; Hammad, G. H.; Aldá Júnior, W. L.; Alves, F. L.; Alves, G. A.; Brito, L.; Correa Martins Junior, M.; Hamer, M.; Hensel, C.; Moraes, A.; Pol, M. E.; Rebello Teles, P.; Belchior Batista Das Chagas, E.; Carvalho, W.; Chinellato, J.; Custódio, A.; Da Costa, E. M.; De Jesus Damiao, D.; De Oliveira Martins, C.; Fonseca De Souza, S.; Huertas Guativa, L. M.; Malbouisson, H.; Matos Figueiredo, D.; Mora Herrera, C.; Mundim, L.; Nogima, H.; Prado Da Silva, W. L.; Santoro, A.; Sznajder, A.; Tonelli Manganote, E. J.; Vilela Pereira, A.; Ahuja, S.; Bernardes, C. A.; De Souza Santos, A.; Dogra, S.; Tomei, T. R. Fernandez Perez; Gregores, E. M.; Mercadante, P. G.; Moon, C. S.; Novaes, S. F.; Padula, Sandra S.; Romero Abad, D.; Ruiz Vargas, J. C.; Aleksandrov, A.; Hadjiiska, R.; Iaydjiev, P.; Rodozov, M.; Stoykova, S.; Sultanov, G.; Vutova, M.; Dimitrov, A.; Glushkov, I.; Litov, L.; Pavlov, B.; Petkov, P.; Ahmad, M.; Bian, J. G.; Chen, G. M.; Chen, H. S.; Chen, M.; Cheng, T.; Du, R.; Jiang, C. H.; Leggat, D.; Plestina, R.; Romeo, F.; Shaheen, S. M.; Spiezia, A.; Tao, J.; Wang, C.; Wang, Z.; Zhang, H.; Asawatangtrakuldee, C.; Ban, Y.; Li, Q.; Liu, S.; Mao, Y.; Qian, S. J.; Wang, D.; Xu, Z.; Avila, C.; Cabrera, A.; Chaparro Sierra, L. F.; Florez, C.; Gomez, J. P.; Gomez Moreno, B.; Sanabria, J. C.; Godinovic, N.; Lelas, D.; Puljak, I.; Ribeiro Cipriano, P. M.; Antunovic, Z.; Kovac, M.; Brigljevic, V.; Kadija, K.; Luetic, J.; Micanovic, S.; Sudic, L.; Attikis, A.; Mavromanolakis, G.; Mousa, J.; Nicolaou, C.; Ptochos, F.; Razis, P. A.; Rykaczewski, H.; Bodlak, M.; Finger, M.; Finger, M.; Abdelalim, A. A.; Awad, A.; Mahrous, A.; Radi, A.; Calpas, B.; Kadastik, M.; Murumaa, M.; Raidal, M.; Tiko, A.; Veelken, C.; Eerola, P.; Pekkanen, J.; Voutilainen, M.; Härkönen, J.; Karimäki, V.; Kinnunen, R.; Lampén, T.; Lassila-Perini, K.; Lehti, S.; Lindén, T.; Luukka, P.; Peltola, T.; Tuominiemi, J.; Tuovinen, E.; Wendland, L.; Talvitie, J.; Tuuva, T.; Besancon, M.; Couderc, F.; Dejardin, M.; Denegri, D.; Fabbro, B.; Faure, J. L.; Favaro, C.; Ferri, F.; Ganjour, S.; Givernaud, A.; Gras, P.; Hamel de Monchenault, G.; Jarry, P.; Locci, E.; Machet, M.; Malcles, J.; Rander, J.; Rosowsky, A.; Titov, M.; Zghiche, A.; Antropov, I.; Baffioni, S.; Beaudette, F.; Busson, P.; Cadamuro, L.; Chapon, E.; Charlot, C.; Davignon, O.; Filipovic, N.; Granier de Cassagnac, R.; Jo, M.; Lisniak, S.; Mastrolorenzo, L.; Miné, P.; Naranjo, I. N.; Nguyen, M.; Ochando, C.; Ortona, G.; Paganini, P.; Pigard, P.; Regnard, S.; Salerno, R.; Sauvan, J. B.; Sirois, Y.; Strebler, T.; Yilmaz, Y.; Zabi, A.; Agram, J.-L.; Andrea, J.; Aubin, A.; Bloch, D.; Brom, J.-M.; Buttignol, M.; Chabert, E. C.; Chanon, N.; Collard, C.; Conte, E.; Coubez, X.; Fontaine, J.-C.; Gelé, D.; Goerlach, U.; Goetzmann, C.; Le Bihan, A.-C.; Merlin, J. A.; Skovpen, K.; Van Hove, P.; Gadrat, S.; Beauceron, S.; Bernet, C.; Boudoul, G.; Bouvier, E.; Carrillo Montoya, C. A.; Chierici, R.; Contardo, D.; Courbon, B.; Depasse, P.; El Mamouni, H.; Fan, J.; Fay, J.; Gascon, S.; Gouzevitch, M.; Ille, B.; Lagarde, F.; Laktineh, I. B.; Lethuillier, M.; Mirabito, L.; Pequegnot, A. L.; Perries, S.; Ruiz Alvarez, J. D.; Sabes, D.; Sgandurra, L.; Sordini, V.; Vander Donckt, M.; Verdier, P.; Viret, S.; Toriashvili, T.; Tsamalaidze, Z.; Autermann, C.; Beranek, S.; Feld, L.; Heister, A.; Kiesel, M. K.; Klein, K.; Lipinski, M.; Ostapchuk, A.; Preuten, M.; Raupach, F.; Schael, S.; Schulte, J. F.; Verlage, T.; Weber, H.; Zhukov, V.; Ata, M.; Brodski, M.; Dietz-Laursonn, E.; Duchardt, D.; Endres, M.; Erdmann, M.; Erdweg, S.; Esch, T.; Fischer, R.; Güth, A.; Hebbeker, T.; Heidemann, C.; Hoepfner, K.; Knutzen, S.; Kreuzer, P.; Merschmeyer, M.; Meyer, A.; Millet, P.; Mukherjee, S.; Olschewski, M.; Padeken, K.; Papacz, P.; Pook, T.; Radziej, M.; Reithler, H.; Rieger, M.; Scheuch, F.; Sonnenschein, L.; Teyssier, D.; Thüer, S.; Cherepanov, V.; Erdogan, Y.; Flügge, G.; Geenen, H.; Geisler, M.; Hoehle, F.; Kargoll, B.; Kress, T.; Künsken, A.; Lingemann, J.; Nehrkorn, A.; Nowack, A.; Nugent, I. M.; Pistone, C.; Pooth, O.; Stahl, A.; Aldaya Martin, M.; Asin, I.; Bartosik, N.; Behnke, O.; Behrens, U.; Borras, K.; Burgmeier, A.; Campbell, A.; Contreras-Campana, C.; Costanza, F.; Diez Pardos, C.; Dolinska, G.; Dooling, S.; Dorland, T.; Eckerlin, G.; Eckstein, D.; Eichhorn, T.; Flucke, G.; Gallo, E.; Garay Garcia, J.; Geiser, A.; Gizhko, A.; Gunnellini, P.; Hauk, J.; Hempel, M.; Jung, H.; Kalogeropoulos, A.; Karacheban, O.; Kasemann, M.; Katsas, P.; Kieseler, J.; Kleinwort, C.; Korol, I.; Lange, W.; Leonard, J.; Lipka, K.; Lobanov, A.; Lohmann, W.; Mankel, R.; Melzer-Pellmann, I.-A.; Meyer, A. B.; Mittag, G.; Mnich, J.; Mussgiller, A.; Naumann-Emme, S.; Nayak, A.; Ntomari, E.; Perrey, H.; Pitzl, D.; Placakyte, R.; Raspereza, A.; Roland, B.; Sahin, M. Ö.; Saxena, P.; Schoerner-Sadenius, T.; Seitz, C.; Spannagel, S.; Trippkewitz, K. D.; Walsh, R.; Wissing, C.; Blobel, V.; Centis Vignali, M.; Draeger, A. R.; Erfle, J.; Garutti, E.; Goebel, K.; Gonzalez, D.; Görner, M.; Haller, J.; Hoffmann, M.; Höing, R. S.; Junkes, A.; Klanner, R.; Kogler, R.; Kovalchuk, N.; Lapsien, T.; Lenz, T.; Marchesini, I.; Marconi, D.; Meyer, M.; Nowatschin, D.; Ott, J.; Pantaleo, F.; Peiffer, T.; Perieanu, A.; Pietsch, N.; Poehlsen, J.; Rathjens, D.; Sander, C.; Scharf, C.; Schleper, P.; Schlieckau, E.; Schmidt, A.; Schumann, S.; Schwandt, J.; Sola, V.; Stadie, H.; Steinbrück, G.; Stober, F. M.; Tholen, H.; Troendle, D.; Usai, E.; Vanelderen, L.; Vanhoefer, A.; Vormwald, B.; Barth, C.; Baus, C.; Berger, J.; Böser, C.; Butz, E.; Chwalek, T.; Colombo, F.; De Boer, W.; Descroix, A.; Dierlamm, A.; Fink, S.; Frensch, F.; Friese, R.; Giffels, M.; Gilbert, A.; Haitz, D.; Hartmann, F.; Heindl, S. M.; Husemann, U.; Katkov, I.; Kornmayer, A.; Lobelle Pardo, P.; Maier, B.; Mildner, H.; Mozer, M. U.; Müller, T.; Müller, Th.; Plagge, M.; Quast, G.; Rabbertz, K.; Röcker, S.; Roscher, F.; Schröder, M.; Sieber, G.; Simonis, H. J.; Ulrich, R.; Wagner-Kuhr, J.; Wayand, S.; Weber, M.; Weiler, T.; Williamson, S.; Wöhrmann, C.; Wolf, R.; Anagnostou, G.; Daskalakis, G.; Geralis, T.; Giakoumopoulou, V. A.; Kyriakis, A.; Loukas, D.; Psallidas, A.; Topsis-Giotis, I.; Agapitos, A.; Kesisoglou, S.; Panagiotou, A.; Saoulidou, N.; Tziaferi, E.; Evangelou, I.; Flouris, G.; Foudas, C.; Kokkas, P.; Loukas, N.; Manthos, N.; Papadopoulos, I.; Paradas, E.; Strologas, J.; Bencze, G.; Hajdu, C.; Hazi, A.; Hidas, P.; Horvath, D.; Sikler, F.; Veszpremi, V.; Vesztergombi, G.; Zsigmond, A. J.; Beni, N.; Czellar, S.; Karancsi, J.; Molnar, J.; Szillasi, Z.; Bartók, M.; Makovec, A.; Raics, P.; Trocsanyi, Z. L.; Ujvari, B.; Choudhury, S.; Mal, P.; Mandal, K.; Sahoo, D. K.; Sahoo, N.; Swain, S. K.; Bansal, S.; Beri, S. B.; Bhatnagar, V.; Chawla, R.; Gupta, R.; Bhawandeep, U.; Kalsi, A. K.; Kaur, A.; Kaur, M.; Kumar, R.; Mehta, A.; Mittal, M.; Singh, J. B.; Walia, G.; Kumar, Ashok; Bhardwaj, A.; Choudhary, B. C.; Garg, R. B.; Malhotra, S.; Naimuddin, M.; Nishu, N.; Ranjan, K.; Sharma, R.; Sharma, V.; Bhattacharya, S.; Chatterjee, K.; Dey, S.; Dutta, S.; Majumdar, N.; Modak, A.; Mondal, K.; Mukhopadhyay, S.; Roy, A.; Roy, D.; Roy Chowdhury, S.; Sarkar, S.; Sharan, M.; Abdulsalam, A.; Chudasama, R.; Dutta, D.; Jha, V.; Kumar, V.; Mohanty, A. K.; Pant, L. M.; Shukla, P.; Topkar, A.; Aziz, T.; Banerjee, S.; Bhowmik, S.; Chatterjee, R. M.; Dewanjee, R. K.; Dugad, S.; Ganguly, S.; Ghosh, S.; Guchait, M.; Gurtu, A.; Jain, Sa.; Kole, G.; Kumar, S.; Mahakud, B.; Maity, M.; Majumder, G.; Mazumdar, K.; Mitra, S.; Mohanty, G. B.; Parida, B.; Sarkar, T.; Sur, N.; Sutar, B.; Wickramage, N.; Chauhan, S.; Dube, S.; Kapoor, A.; Kothekar, K.; Sharma, S.; Bakhshiansohi, H.; Behnamian, H.; Etesami, S. M.; Fahim, A.; Khakzad, M.; Mohammadi Najafabadi, M.; Naseri, M.; Paktinat Mehdiabadi, S.; Rezaei Hosseinabadi, F.; Safarzadeh, B.; Zeinali, M.; Felcini, M.; Grunewald, M.; Abbrescia, M.; Calabria, C.; Caputo, C.; Colaleo, A.; Creanza, D.; Cristella, L.; De Filippis, N.; De Palma, M.; Fiore, L.; Iaselli, G.; Maggi, G.; Maggi, M.; Miniello, G.; My, S.; Nuzzo, S.; Pompili, A.; Pugliese, G.; Radogna, R.; Ranieri, A.; Selvaggi, G.; Silvestris, L.; Venditti, R.; Abbiendi, G.; Battilana, C.; Benvenuti, A. C.; Bonacorsi, D.; Braibant-Giacomelli, S.; Brigliadori, L.; Campanini, R.; Capiluppi, P.; Castro, A.; Cavallo, F. R.; Chhibra, S. S.; Codispoti, G.; Cuffiani, M.; Dallavalle, G. M.; Fabbri, F.; Fanfani, A.; Fasanella, D.; Giacomelli, P.; Grandi, C.; Guiducci, L.; Marcellini, S.; Masetti, G.; Montanari, A.; Navarria, F. L.; Perrotta, A.; Rossi, A. M.; Rovelli, T.; Siroli, G. P.; Tosi, N.; Cappello, G.; Chiorboli, M.; Costa, S.; Di Mattia, A.; Giordano, F.; Potenza, R.; Tricomi, A.; Tuve, C.; Barbagli, G.; Ciulli, V.; Civinini, C.; D'Alessandro, R.; Focardi, E.; Gori, V.; Lenzi, P.; Meschini, M.; Paoletti, S.; Sguazzoni, G.; Viliani, L.; Benussi, L.; Bianco, S.; Fabbri, F.; Piccolo, D.; Primavera, F.; Calvelli, V.; Ferro, F.; Lo Vetere, M.; Monge, M. R.; Robutti, E.; Tosi, S.; Brianza, L.; Dinardo, M. E.; Fiorendi, S.; Gennai, S.; Gerosa, R.; Ghezzi, A.; Govoni, P.; Malvezzi, S.; Manzoni, R. A.; Marzocchi, B.; Menasce, D.; Moroni, L.; Paganoni, M.; Pedrini, D.; Ragazzi, S.; Redaelli, N.; Tabarelli de Fatis, T.; Buontempo, S.; Cavallo, N.; Di Guida, S.; Esposito, M.; Fabozzi, F.; Iorio, A. O. M.; Lanza, G.; Lista, L.; Meola, S.; Merola, M.; Paolucci, P.; Sciacca, C.; Thyssen, F.; Azzi, P.; Bacchetta, N.; Bellato, M.; Benato, L.; Boletti, A.; Branca, A.; Dall'Osso, M.; Dorigo, T.; Fantinel, S.; Fanzago, F.; Gonella, F.; Gozzelino, A.; Kanishchev, K.; Lacaprara, S.; Margoni, M.; Meneguzzo, A. T.; Montecassiano, F.; Passaseo, M.; Pazzini, J.; Pegoraro, M.; Pozzobon, N.; Ronchese, P.; Simonetto, F.; Torassa, E.; Tosi, M.; Ventura, S.; Zanetti, M.; Zotto, P.; Zucchetta, A.; Braghieri, A.; Magnani, A.; Montagna, P.; Ratti, S. P.; Re, V.; Riccardi, C.; Salvini, P.; Vai, I.; Vitulo, P.; Alunni Solestizi, L.; Bilei, G. M.; Ciangottini, D.; Fanò, L.; Lariccia, P.; Mantovani, G.; Menichelli, M.; Saha, A.; Santocchia, A.; Androsov, K.; Azzurri, P.; Bagliesi, G.; Bernardini, J.; Boccali, T.; Castaldi, R.; Ciocci, M. A.; Dell'Orso, R.; Donato, S.; Fedi, G.; Foà, L.; Giassi, A.; Grippo, M. T.; Ligabue, F.; Lomtadze, T.; Martini, L.; Messineo, A.; Palla, F.; Rizzi, A.; Savoy-Navarro, A.; Serban, A. T.; Spagnolo, P.; Tenchini, R.; Tonelli, G.; Venturi, A.; Verdini, P. G.; Barone, L.; Cavallari, F.; D'imperio, G.; Del Re, D.; Diemoz, M.; Gelli, S.; Jorda, C.; Longo, E.; Margaroli, F.; Meridiani, P.; Organtini, G.; Paramatti, R.; Preiato, F.; Rahatlou, S.; Rovelli, C.; Santanastasio, F.; Traczyk, P.; Amapane, N.; Arcidiacono, R.; Argiro, S.; Arneodo, M.; Bellan, R.; Biino, C.; Cartiglia, N.; Costa, M.; Covarelli, R.; Degano, A.; Demaria, N.; Finco, L.; Kiani, B.; Mariotti, C.; Maselli, S.; Migliore, E.; Monaco, V.; Monteil, E.; Obertino, M. M.; Pacher, L.; Pastrone, N.; Pelliccioni, M.; Pinna Angioni, G. L.; Ravera, F.; Romero, A.; Ruspa, M.; Sacchi, R.; Solano, A.; Staiano, A.; Belforte, S.; Candelise, V.; Casarsa, M.; Cossutti, F.; Della Ricca, G.; Gobbo, B.; La Licata, C.; Marone, M.; Schizzi, A.; Zanetti, A.; Kropivnitskaya, A.; Nam, S. K.; Kim, D. H.; Kim, G. N.; Kim, M. S.; Kong, D. J.; Lee, S.; Oh, Y. D.; Sakharov, A.; Son, D. C.; Brochero Cifuentes, J. A.; Kim, H.; Kim, T. J.; Song, S.; Cho, S.; Choi, S.; Go, Y.; Gyun, D.; Hong, B.; Kim, H.; Kim, Y.; Lee, B.; Lee, K.; Lee, K. S.; Lee, S.; Park, S. K.; Roh, Y.; Yoo, H. D.; Choi, M.; Kim, H.; Kim, J. H.; Lee, J. S. H.; Park, I. C.; Ryu, G.; Ryu, M. S.; Choi, Y.; Goh, J.; Kim, D.; Kwon, E.; Lee, J.; Yu, I.; Dudenas, V.; Juodagalvis, A.; Vaitkus, J.; Ahmed, I.; Ibrahim, Z. A.; Komaragiri, J. R.; Md Ali, M. A. B.; Mohamad Idris, F.; Wan Abdullah, W. A. T.; Yusli, M. N.; Zolkapli, Z.; Casimiro Linares, E.; Castilla-Valdez, H.; De La Cruz-Burelo, E.; Heredia-De La Cruz, I.; Hernandez-Almada, A.; Lopez-Fernandez, R.; Sanchez-Hernandez, A.; Carrillo Moreno, S.; Vazquez Valencia, F.; Pedraza, I.; Salazar Ibarguen, H. A.; Morelos Pineda, A.; Krofcheck, D.; Butler, P. H.; Ahmad, A.; Ahmad, M.; Hassan, Q.; Hoorani, H. R.; Khan, W. A.; Khurshid, T.; Shoaib, M.; Bialkowska, H.; Bluj, M.; Boimska, B.; Frueboes, T.; Górski, M.; Kazana, M.; Nawrocki, K.; Romanowska-Rybinska, K.; Szleper, M.; Zalewski, P.; Brona, G.; Bunkowski, K.; Byszuk, A.; Doroba, K.; Kalinowski, A.; Konecki, M.; Krolikowski, J.; Misiura, M.; Olszewski, M.; Walczak, M.; Bargassa, P.; Beirão Da Cruz E Silva, C.; Di Francesco, A.; Faccioli, P.; Ferreira Parracho, P. G.; Gallinaro, M.; Hollar, J.; Leonardo, N.; Lloret Iglesias, L.; Nguyen, F.; Rodrigues Antunes, J.; Seixas, J.; Toldaiev, O.; Vadruccio, D.; Varela, J.; Vischia, P.; Afanasiev, S.; Bunin, P.; Gavrilenko, M.; Golutvin, I.; Gorbunov, I.; Kamenev, A.; Karjavin, V.; Lanev, A.; Malakhov, A.; Matveev, V.; Moisenz, P.; Palichik, V.; Perelygin, V.; Shmatov, S.; Shulha, S.; Skatchkov, N.; Smirnov, V.; Zarubin, A.; Golovtsov, V.; Ivanov, Y.; Kim, V.; Kuznetsova, E.; Levchenko, P.; Murzin, V.; Oreshkin, V.; Smirnov, I.; Sulimov, V.; Uvarov, L.; Vavilov, S.; Vorobyev, A.; Andreev, Yu.; Dermenev, A.; Gninenko, S.; Golubev, N.; Karneyeu, A.; Kirsanov, M.; Krasnikov, N.; Pashenkov, A.; Tlisov, D.; Toropin, A.; Epshteyn, V.; Gavrilov, V.; Lychkovskaya, N.; Popov, V.; Pozdnyakov, I.; Safronov, G.; Spiridonov, A.; Vlasov, E.; Zhokin, A.; Bylinkin, A.; Chadeeva, M.; Danilov, M.; Andreev, V.; Azarkin, M.; Dremin, I.; Kirakosyan, M.; Leonidov, A.; Mesyats, G.; Rusakov, S. V.; Baskakov, A.; Belyaev, A.; Boos, E.; Ershov, A.; Gribushin, A.; Kaminskiy, A.; Kodolova, O.; Korotkikh, V.; Lokhtin, I.; Miagkov, I.; Obraztsov, S.; Petrushanko, S.; Savrin, V.; Snigirev, A.; Vardanyan, I.; Azhgirey, I.; Bayshev, I.; Bitioukov, S.; Kachanov, V.; Kalinin, A.; Konstantinov, D.; Krychkine, V.; Petrov, V.; Ryutin, R.; Sobol, A.; Tourtchanovitch, L.; Troshin, S.; Tyurin, N.; Uzunian, A.; Volkov, A.; Adzic, P.; Cirkovic, P.; Milosevic, J.; Rekovic, V.; Alcaraz Maestre, J.; Calvo, E.; Cerrada, M.; Chamizo Llatas, M.; Colino, N.; De La Cruz, B.; Delgado Peris, A.; Escalante Del Valle, A.; Fernandez Bedoya, C.; Fernández Ramos, J. P.; Flix, J.; Fouz, M. C.; Garcia-Abia, P.; Gonzalez Lopez, O.; Goy Lopez, S.; Hernandez, J. M.; Josa, M. I.; Navarro De Martino, E.; Pérez-Calero Yzquierdo, A.; Puerta Pelayo, J.; Quintario Olmeda, A.; Redondo, I.; Romero, L.; Santaolalla, J.; Soares, M. S.; Albajar, C.; de Trocóniz, J. F.; Missiroli, M.; Moran, D.; Cuevas, J.; Fernandez Menendez, J.; Folgueras, S.; Gonzalez Caballero, I.; Palencia Cortezon, E.; Vizan Garcia, J. M.; Cabrillo, I. J.; Calderon, A.; Castiñeiras De Saa, J. R.; De Castro Manzano, P.; Fernandez, M.; Garcia-Ferrero, J.; Gomez, G.; Lopez Virto, A.; Marco, J.; Marco, R.; Martinez Rivero, C.; Matorras, F.; Piedra Gomez, J.; Rodrigo, T.; Rodríguez-Marrero, A. Y.; Ruiz-Jimeno, A.; Scodellaro, L.; Trevisani, N.; Vila, I.; Vilar Cortabitarte, R.; Abbaneo, D.; Auffray, E.; Auzinger, G.; Bachtis, M.; Baillon, P.; Ball, A. H.; Barney, D.; Benaglia, A.; Bendavid, J.; Benhabib, L.; Berruti, G. M.; Bloch, P.; Bocci, A.; Bonato, A.; Botta, C.; Breuker, H.; Camporesi, T.; Castello, R.; Cerminara, G.; D'Alfonso, M.; d'Enterria, D.; Dabrowski, A.; Daponte, V.; David, A.; De Gruttola, M.; De Guio, F.; De Roeck, A.; De Visscher, S.; Di Marco, E.; Dobson, M.; Dordevic, M.; Dorney, B.; du Pree, T.; Duggan, D.; Dünser, M.; Dupont, N.; Elliott-Peisert, A.; Franzoni, G.; Fulcher, J.; Funk, W.; Gigi, D.; Gill, K.; Giordano, D.; Girone, M.; Glege, F.; Guida, R.; Gundacker, S.; Guthoff, M.; Hammer, J.; Harris, P.; Hegeman, J.; Innocente, V.; Janot, P.; Kirschenmann, H.; Kortelainen, M. J.; Kousouris, K.; Krajczar, K.; Lecoq, P.; Lourenço, C.; Lucchini, M. T.; Magini, N.; Malgeri, L.; Mannelli, M.; Martelli, A.; Masetti, L.; Meijers, F.; Mersi, S.; Meschi, E.; Moortgat, F.; Morovic, S.; Mulders, M.; Nemallapudi, M. V.; Neugebauer, H.; Orfanelli, S.; Orsini, L.; Pape, L.; Perez, E.; Peruzzi, M.; Petrilli, A.; Petrucciani, G.; Pfeiffer, A.; Pierini, M.; Piparo, D.; Racz, A.; Reis, T.; Rolandi, G.; Rovere, M.; Ruan, M.; Sakulin, H.; Schäfer, C.; Schwick, C.; Seidel, M.; Sharma, A.; Silva, P.; Simon, M.; Sphicas, P.; Steggemann, J.; Stieger, B.; Stoye, M.; Takahashi, Y.; Treille, D.; Triossi, A.; Tsirou, A.; Veres, G. I.; Wardle, N.; Wöhri, H. K.; Zagozdzinska, A.; Zeuner, W. D.; Bertl, W.; Deiters, K.; Erdmann, W.; Horisberger, R.; Ingram, Q.; Kaestli, H. C.; Kotlinski, D.; Langenegger, U.; Rohe, T.; Bachmair, F.; Bäni, L.; Bianchini, L.; Casal, B.; Dissertori, G.; Dittmar, M.; Donegá, M.; Eller, P.; Grab, C.; Heidegger, C.; Hits, D.; Hoss, J.; Kasieczka, G.; Lecomte, P.; Lustermann, W.; Mangano, B.; Marionneau, M.; Martinez Ruiz del Arbol, P.; Masciovecchio, M.; Meister, D.; Micheli, F.; Musella, P.; Nessi-Tedaldi, F.; Pandolfi, F.; Pata, J.; Pauss, F.; Perrozzi, L.; Quittnat, M.; Rossini, M.; Schönenberger, M.; Starodumov, A.; Takahashi, M.; Tavolaro, V. R.; Theofilatos, K.; Wallny, R.; Aarrestad, T. K.; Amsler, C.; Caminada, L.; Canelli, M. F.; Chiochia, V.; De Cosa, A.; Galloni, C.; Hinzmann, A.; Hreus, T.; Kilminster, B.; Lange, C.; Ngadiuba, J.; Pinna, D.; Rauco, G.; Robmann, P.; Salerno, D.; Yang, Y.; Cardaci, M.; Chen, K. H.; Doan, T. H.; Jain, Sh.; Khurana, R.; Konyushikhin, M.; Kuo, C. M.; Lin, W.; Lu, Y. J.; Pozdnyakov, A.; Yu, S. S.; Kumar, Arun; Chang, P.; Chang, Y. H.; Chang, Y. W.; Chao, Y.; Chen, K. F.; Chen, P. H.; Dietz, C.; Fiori, F.; Grundler, U.; Hou, W.-S.; Hsiung, Y.; Liu, Y. F.; Lu, R.-S.; Miñano Moya, M.; Petrakou, E.; Tsai, J. f.; Tzeng, Y. M.; Asavapibhop, B.; Kovitanggoon, K.; Singh, G.; Srimanobhas, N.; Suwonjandee, N.; Adiguzel, A.; Cerci, S.; Demiroglu, Z. S.; Dozen, C.; Dumanoglu, I.; Gecit, F. H.; Girgis, S.; Gokbulut, G.; Guler, Y.; Gurpinar, E.; Hos, I.; Kangal, E. E.; Kayis Topaksu, A.; Onengut, G.; Ozcan, M.; Ozdemir, K.; Ozturk, S.; Tali, B.; Topakli, H.; Zorbilmez, C.; Bilin, B.; Bilmis, S.; Isildak, B.; Karapinar, G.; Yalvac, M.; Zeyrek, M.; Gülmez, E.; Kaya, M.; Kaya, O.; Yetkin, E. A.; Yetkin, T.; Cakir, A.; Cankocak, K.; Sen, S.; Vardarlí, F. I.; Grynyov, B.; Levchuk, L.; Sorokin, P.; Aggleton, R.; Ball, F.; Beck, L.; Brooke, J. J.; Clement, E.; Cussans, D.; Flacher, H.; Goldstein, J.; Grimes, M.; Heath, G. P.; Heath, H. F.; Jacob, J.; Kreczko, L.; Lucas, C.; Meng, Z.; Newbold, D. M.; Paramesvaran, S.; Poll, A.; Sakuma, T.; Seif El Nasr-storey, S.; Senkin, S.; Smith, D.; Smith, V. J.; Belyaev, A.; Brew, C.; Brown, R. M.; Calligaris, L.; Cieri, D.; Cockerill, D. J. A.; Coughlan, J. A.; Harder, K.; Harper, S.; Olaiya, E.; Petyt, D.; Shepherd-Themistocleous, C. H.; Thea, A.; Tomalin, I. R.; Williams, T.; Worm, S. D.; Baber, M.; Bainbridge, R.; Buchmuller, O.; Bundock, A.; Burton, D.; Casasso, S.; Citron, M.; Colling, D.; Corpe, L.; Dauncey, P.; Davies, G.; De Wit, A.; Della Negra, M.; Dunne, P.; Elwood, A.; Futyan, D.; Hall, G.; Iles, G.; Lane, R.; Lucas, R.; Lyons, L.; Magnan, A.-M.; Malik, S.; Nash, J.; Nikitenko, A.; Pela, J.; Pesaresi, M.; Raymond, D. M.; Richards, A.; Rose, A.; Seez, C.; Tapper, A.; Uchida, K.; Vazquez Acosta, M.; Virdee, T.; Zenz, S. C.; Cole, J. E.; Hobson, P. R.; Khan, A.; Kyberd, P.; Leslie, D.; Reid, I. D.; Symonds, P.; Teodorescu, L.; Turner, M.; Borzou, A.; Call, K.; Dittmann, J.; Hatakeyama, K.; Liu, H.; Pastika, N.; Charaf, O.; Cooper, S. I.; Henderson, C.; Rumerio, P.; Arcaro, D.; Avetisyan, A.; Bose, T.; Gastler, D.; Rankin, D.; Richardson, C.; Rohlf, J.; Sulak, L.; Zou, D.; Alimena, J.; Berry, E.; Cutts, D.; Ferapontov, A.; Garabedian, A.; Hakala, J.; Heintz, U.; Jesus, O.; Laird, E.; Landsberg, G.; Mao, Z.; Narain, M.; Piperov, S.; Sagir, S.; Syarif, R.; Breedon, R.; Breto, G.; Calderon De La Barca Sanchez, M.; Chauhan, S.; Chertok, M.; Conway, J.; Conway, R.; Cox, P. T.; Erbacher, R.; Funk, G.; Gardner, M.; Ko, W.; Lander, R.; Mclean, C.; Mulhearn, M.; Pellett, D.; Pilot, J.; Ricci-Tam, F.; Shalhout, S.; Smith, J.; Squires, M.; Stolp, D.; Tripathi, M.; Wilbur, S.; Yohay, R.; Cousins, R.; Everaerts, P.; Florent, A.; Hauser, J.; Ignatenko, M.; Saltzberg, D.; Takasugi, E.; Valuev, V.; Weber, M.; Burt, K.; Clare, R.; Ellison, J.; Gary, J. W.; Hanson, G.; Heilman, J.; Ivova Paneva, M.; Jandir, P.; Kennedy, E.; Lacroix, F.; Long, O. R.; Malberti, M.; Olmedo Negrete, M.; Shrinivas, A.; Wei, H.; Wimpenny, S.; Yates, B. R.; Branson, J. G.; Cerati, G. B.; Cittolin, S.; D'Agnolo, R. T.; Derdzinski, M.; Holzner, A.; Kelley, R.; Klein, D.; Letts, J.; Macneill, I.; Olivito, D.; Padhi, S.; Pieri, M.; Sani, M.; Sharma, V.; Simon, S.; Tadel, M.; Vartak, A.; Wasserbaech, S.; Welke, C.; Würthwein, F.; Yagil, A.; Zevi Della Porta, G.; Bradmiller-Feld, J.; Campagnari, C.; Dishaw, A.; Dutta, V.; Flowers, K.; Franco Sevilla, M.; Geffert, P.; George, C.; Golf, F.; Gouskos, L.; Gran, J.; Incandela, J.; Mccoll, N.; Mullin, S. D.; Richman, J.; Stuart, D.; Suarez, I.; West, C.; Yoo, J.; Anderson, D.; Apresyan, A.; Bornheim, A.; Bunn, J.; Chen, Y.; Duarte, J.; Mott, A.; Newman, H. B.; Pena, C.; Spiropulu, M.; Vlimant, J. R.; Xie, S.; Zhu, R. Y.; Andrews, M. B.; Azzolini, V.; Calamba, A.; Carlson, B.; Ferguson, T.; Paulini, M.; Russ, J.; Sun, M.; Vogel, H.; Vorobiev, I.; Cumalat, J. P.; Ford, W. T.; Gaz, A.; Jensen, F.; Johnson, A.; Krohn, M.; Mulholland, T.; Nauenberg, U.; Stenson, K.; Wagner, S. R.; Alexander, J.; Chatterjee, A.; Chaves, J.; Chu, J.; Dittmer, S.; Eggert, N.; Mirman, N.; Nicolas Kaufman, G.; Patterson, J. R.; Rinkevicius, A.; Ryd, A.; Skinnari, L.; Soffi, L.; Sun, W.; Tan, S. M.; Teo, W. D.; Thom, J.; Thompson, J.; Tucker, J.; Weng, Y.; Wittich, P.; Abdullin, S.; Albrow, M.; Apollinari, G.; Banerjee, S.; Bauerdick, L. A. T.; Beretvas, A.; Berryhill, J.; Bhat, P. C.; Bolla, G.; Burkett, K.; Butler, J. N.; Cheung, H. W. K.; Chlebana, F.; Cihangir, S.; Elvira, V. D.; Fisk, I.; Freeman, J.; Gottschalk, E.; Gray, L.; Green, D.; Grünendahl, S.; Gutsche, O.; Hanlon, J.; Hare, D.; Harris, R. M.; Hasegawa, S.; Hirschauer, J.; Hu, Z.; Jayatilaka, B.; Jindariani, S.; Johnson, M.; Joshi, U.; Klima, B.; Kreis, B.; Lammel, S.; Linacre, J.; Lincoln, D.; Lipton, R.; Liu, T.; Lopes De Sá, R.; Lykken, J.; Maeshima, K.; Marraffino, J. M.; Maruyama, S.; Mason, D.; McBride, P.; Merkel, P.; Mrenna, S.; Nahn, S.; Newman-Holmes, C.; O'Dell, V.; Pedro, K.; Prokofyev, O.; Rakness, G.; Sexton-Kennedy, E.; Soha, A.; Spalding, W. J.; Spiegel, L.; Stoynev, S.; Strobbe, N.; Taylor, L.; Tkaczyk, S.; Tran, N. V.; Uplegger, L.; Vaandering, E. W.; Vernieri, C.; Verzocchi, M.; Vidal, R.; Wang, M.; Weber, H. A.; Whitbeck, A.; Acosta, D.; Avery, P.; Bortignon, P.; Bourilkov, D.; Carnes, A.; Carver, M.; Curry, D.; Das, S.; Field, R. D.; Furic, I. K.; Gleyzer, S. V.; Konigsberg, J.; Korytov, A.; Kotov, K.; Ma, P.; Matchev, K.; Mei, H.; Milenovic, P.; Mitselmakher, G.; Rank, D.; Rossin, R.; Shchutska, L.; Snowball, M.; Sperka, D.; Terentyev, N.; Thomas, L.; Wang, J.; Wang, S.; Yelton, J.; Hewamanage, S.; Linn, S.; Markowitz, P.; Martinez, G.; Rodriguez, J. L.; Ackert, A.; Adams, J. R.; Adams, T.; Askew, A.; Bein, S.; Bochenek, J.; Diamond, B.; Haas, J.; Hagopian, S.; Hagopian, V.; Johnson, K. F.; Khatiwada, A.; Prosper, H.; Weinberg, M.; Baarmand, M. M.; Bhopatkar, V.; Colafranceschi, S.; Hohlmann, M.; Kalakhety, H.; Noonan, D.; Roy, T.; Yumiceva, F.; Adams, M. R.; Apanasevich, L.; Berry, D.; Betts, R. R.; Bucinskaite, I.; Cavanaugh, R.; Evdokimov, O.; Gauthier, L.; Gerber, C. E.; Hofman, D. J.; Kurt, P.; O'Brien, C.; Sandoval Gonzalez, I. D.; Turner, P.; Varelas, N.; Wu, Z.; Zakaria, M.; Bilki, B.; Clarida, W.; Dilsiz, K.; Durgut, S.; Gandrajula, R. P.; Haytmyradov, M.; Khristenko, V.; Merlo, J.-P.; Mermerkaya, H.; Mestvirishvili, A.; Moeller, A.; Nachtman, J.; Ogul, H.; Onel, Y.; Ozok, F.; Penzo, A.; Snyder, C.; Tiras, E.; Wetzel, J.; Yi, K.; Anderson, I.; Barnett, B. A.; Blumenfeld, B.; Eminizer, N.; Fehling, D.; Feng, L.; Gritsan, A. V.; Maksimovic, P.; Martin, C.; Osherson, M.; Roskes, J.; Sady, A.; Sarica, U.; Swartz, M.; Xiao, M.; Xin, Y.; You, C.; Baringer, P.; Bean, A.; Benelli, G.; Bruner, C.; Kenny, R. P.; Majumder, D.; Malek, M.; Mcbrayer, W.; Murray, M.; Sanders, S.; Stringer, R.; Wang, Q.; Ivanov, A.; Kaadze, K.; Khalil, S.; Makouski, M.; Maravin, Y.; Mohammadi, A.; Saini, L. K.; Skhirtladze, N.; Toda, S.; Lange, D.; Rebassoo, F.; Wright, D.; Anelli, C.; Baden, A.; Baron, O.; Belloni, A.; Calvert, B.; Eno, S. C.; Ferraioli, C.; Gomez, J. A.; Hadley, N. J.; Jabeen, S.; Kellogg, R. G.; Kolberg, T.; Kunkle, J.; Lu, Y.; Mignerey, A. C.; Shin, Y. H.; Skuja, A.; Tonjes, M. B.; Tonwar, S. C.; Apyan, A.; Barbieri, R.; Baty, A.; Bierwagen, K.; Brandt, S.; Busza, W.; Cali, I. A.; Demiragli, Z.; Di Matteo, L.; Gomez Ceballos, G.; Goncharov, M.; Gulhan, D.; Iiyama, Y.; Innocenti, G. M.; Klute, M.; Kovalskyi, D.; Lai, Y. S.; Lee, Y.-J.; Levin, A.; Luckey, P. D.; Marini, A. C.; Mcginn, C.; Mironov, C.; Narayanan, S.; Niu, X.; Paus, C.; Roland, C.; Roland, G.; Salfeld-Nebgen, J.; Stephans, G. S. F.; Sumorok, K.; Varma, M.; Velicanu, D.; Veverka, J.; Wang, J.; Wang, T. W.; Wyslouch, B.; Yang, M.; Zhukova, V.; Dahmes, B.; Evans, A.; Finkel, A.; Gude, A.; Hansen, P.; Kalafut, S.; Kao, S. C.; Klapoetke, K.; Kubota, Y.; Lesko, Z.; Mans, J.; Nourbakhsh, S.; Ruckstuhl, N.; Rusack, R.; Tambe, N.; Turkewitz, J.; Acosta, J. G.; Oliveros, S.; Avdeeva, E.; Bartek, R.; Bloom, K.; Bose, S.; Claes, D. R.; Dominguez, A.; Fangmeier, C.; Gonzalez Suarez, R.; Kamalieddin, R.; Knowlton, D.; Kravchenko, I.; Meier, F.; Monroy, J.; Ratnikov, F.; Siado, J. E.; Snow, G. R.; Alyari, M.; Dolen, J.; George, J.; Godshalk, A.; Harrington, C.; Iashvili, I.; Kaisen, J.; Kharchilava, A.; Kumar, A.; Rappoccio, S.; Roozbahani, B.; Alverson, G.; Barberis, E.; Baumgartel, D.; Chasco, M.; Hortiangtham, A.; Massironi, A.; Morse, D. M.; Nash, D.; Orimoto, T.; Teixeira De Lima, R.; Trocino, D.; Wang, R.-J.; Wood, D.; Zhang, J.; Bhattacharya, S.; Hahn, K. A.; Kubik, A.; Low, J. F.; Mucia, N.; Odell, N.; Pollack, B.; Schmitt, M.; Sung, K.; Trovato, M.; Velasco, M.; Brinkerhoff, A.; Dev, N.; Hildreth, M.; Jessop, C.; Karmgard, D. J.; Kellams, N.; Lannon, K.; Marinelli, N.; Meng, F.; Mueller, C.; Musienko, Y.; Planer, M.; Reinsvold, A.; Ruchti, R.; Smith, G.; Taroni, S.; Valls, N.; Wayne, M.; Wolf, M.; Woodard, A.; Antonelli, L.; Brinson, J.; Bylsma, B.; Durkin, L. S.; Flowers, S.; Hart, A.; Hill, C.; Hughes, R.; Ji, W.; Ling, T. Y.; Liu, B.; Luo, W.; Puigh, D.; Rodenburg, M.; Winer, B. L.; Wulsin, H. W.; Driga, O.; Elmer, P.; Hardenbrook, J.; Hebda, P.; Koay, S. A.; Lujan, P.; Marlow, D.; Medvedeva, T.; Mooney, M.; Olsen, J.; Palmer, C.; Piroué, P.; Stickland, D.; Tully, C.; Zuranski, A.; Malik, S.; Barker, A.; Barnes, V. E.; Benedetti, D.; Bortoletto, D.; Gutay, L.; Jha, M. K.; Jones, M.; Jung, A. W.; Jung, K.; Kumar, A.; Miller, D. H.; Neumeister, N.; Radburn-Smith, B. C.; Shi, X.; Shipsey, I.; Silvers, D.; Sun, J.; Svyatkovskiy, A.; Wang, F.; Xie, W.; Xu, L.; Parashar, N.; Stupak, J.; Adair, A.; Akgun, B.; Chen, Z.; Ecklund, K. M.; Geurts, F. J. M.; Guilbaud, M.; Li, W.; Michlin, B.; Northup, M.; Padley, B. P.; Redjimi, R.; Roberts, J.; Rorie, J.; Tu, Z.; Zabel, J.; Betchart, B.; Bodek, A.; de Barbaro, P.; Demina, R.; Eshaq, Y.; Ferbel, T.; Galanti, M.; Garcia-Bellido, A.; Han, J.; Harel, A.; Hindrichs, O.; Khukhunaishvili, A.; Lo, K. H.; Petrillo, G.; Tan, P.; Verzetti, M.; Chou, J. P.; Contreras-Campana, E.; Ferencek, D.; Gershtein, Y.; Halkiadakis, E.; Heindl, M.; Hidas, D.; Hughes, E.; Kaplan, S.; Kunnawalkam Elayavalli, R.; Lath, A.; Nash, K.; Saka, H.; Salur, S.; Schnetzer, S.; Sheffield, D.; Somalwar, S.; Stone, R.; Thomas, S.; Thomassen, P.; Walker, M.; Foerster, M.; Riley, G.; Rose, K.; Spanier, S.; Thapa, K.; Bouhali, O.; Castaneda Hernandez, A.; Celik, A.; Dalchenko, M.; De Mattia, M.; Delgado, A.; Dildick, S.; Eusebi, R.; Gilmore, J.; Huang, T.; Kamon, T.; Krutelyov, V.; Mueller, R.; Osipenkov, I.; Pakhotin, Y.; Patel, R.; Perloff, A.; Rose, A.; Safonov, A.; Tatarinov, A.; Ulmer, K. A.; Akchurin, N.; Cowden, C.; Damgov, J.; Dragoiu, C.; Dudero, P. R.; Faulkner, J.; Kunori, S.; Lamichhane, K.; Lee, S. W.; Libeiro, T.; Undleeb, S.; Volobouev, I.; Appelt, E.; Delannoy, A. G.; Greene, S.; Gurrola, A.; Janjam, R.; Johns, W.; Maguire, C.; Mao, Y.; Melo, A.; Ni, H.; Sheldon, P.; Tuo, S.; Velkovska, J.; Xu, Q.; Arenton, M. W.; Cox, B.; Francis, B.; Goodell, J.; Hirosky, R.; Ledovskoy, A.; Li, H.; Lin, C.; Neu, C.; Sinthuprasith, T.; Sun, X.; Wang, Y.; Wolfe, E.; Wood, J.; Xia, F.; Clarke, C.; Harr, R.; Karchin, P. E.; Kottachchi Kankanamge Don, C.; Lamichhane, P.; Sturdy, J.; Belknap, D. A.; Carlsmith, D.; Cepeda, M.; Dasu, S.; Dodd, L.; Duric, S.; Gomber, B.; Grothe, M.; Herndon, M.; Hervé, A.; Klabbers, P.; Lanaro, A.; Levine, A.; Long, K.; Loveless, R.; Mohapatra, A.; Ojalvo, I.; Perry, T.; Pierro, G. A.; Polese, G.; Ruggles, T.; Sarangi, T.; Savin, A.; Sharma, A.; Smith, N.; Smith, W. H.; Taylor, D.; Verwilligen, P.; Woods, N.; CMS Collaboration
2017-07-01
Two-particle correlations in p Pb collisions at a nucleon-nucleon center-of-mass energy of 5.02 TeV are studied as a function of the pseudorapidity separation (Δ η ) of the particle pair at small relative azimuthal angle (|Δ ϕ |<π /3 ). The correlations are decomposed into a jet component that dominates the short-range correlations (|Δ η |<1 ), and a component that persists at large Δ η and may originate from collective behavior of the produced system. The events are classified in terms of the multiplicity of the produced particles. Finite azimuthal anisotropies are observed in high-multiplicity events. The second and third Fourier components of the particle-pair azimuthal correlations, V2 and V3, are extracted after subtraction of the jet component. The single-particle anisotropy parameters v2 and v3 are normalized by their laboratory frame midrapidity value and are studied as a function of ηc.m.. The normalized v2 distribution is found to be asymmetric about ηc.m.=0 , with smaller values observed at forward pseudorapidity, corresponding to the direction of the proton beam, while no significant pseudorapidity dependence is observed for the normalized v3 distribution within the statistical uncertainties.
Kraut, Jeffrey A; Nagami, Glenn T
2013-11-01
The serum anion gap has been utilized to identify errors in the measurement of electrolytes, to detect paraproteins, and, most relevant to the nephrologist, to evaluate patients with suspected acid-base disorders. In regard to the latter purpose, traditionally an increased anion gap is identified when it exceeds the upper limit of normal for a particular clinical laboratory measurement. However, because there is a wide range of normal values (often 8-10 mEq/L), an increase in anion concentration can be present in the absence of an increased anion gap. In addition, the type of retained anion can affect the magnitude of the increase in anion gap relative to change in serum [HCO3(-)] being greater with lactic acidosis compared with ketoacidosis. This review examines the methods of calculation of the serum anion gap in textbooks and published literature, the effect of perturbations other than changes in acid-base balance, and its effectiveness in identifying mild and more severe disturbances in acid-base balance. Limitations of the present methods of determining the normal anion gap and change in the anion gap are highlighted. The possibility of identifying the baseline value for individuals to optimize the use of the calculation in the detection of metabolic acidosis is suggested.
[Development of the certified reference material of mercury in lyophilized human urine].
Zhao, Wei; Zhang, Fu-gang; DU, Hui-fang; Pan, Ya-juan; Yan, Hui-fang
2011-02-01
To develop the certified reference material of mercury in lyophilized human urine. Human urine samples from normal level mercury districts were filtered, homogenized, dispensed, lyophilized and radio-sterilized. Homogeneity test, stability inspection and certification were conducted using a atom fluorescence spectrophotometric method. The physical and chemical stability of the certified reference material were assessed for 18 months. The certified values are based on analysis made by three independent laboratories. The certified values are as follows: low level was (35.6 ± 2.1) µg/L, high level was (50.5 ± 3.0) µg/L. The certified reference material of mercury in lyophilized human urine in this research reached the national certified reference material requirements and could be used for the quality control.
Schroder, L.J.; Brooks, M.H.; Malo, B.A.; Willoughby, T.C.
1986-01-01
Five intersite comparison studies for the field determination of pH and specific conductance, using simulated-precipitation samples, were conducted by the U.S.G.S. for the National Atmospheric Deposition Program and National Trends Network. These comparisons were performed to estimate the precision of pH and specific conductance determinations made by sampling-site operators. Simulated-precipitation samples were prepared from nitric acid and deionized water. The estimated standard deviation for site-operator determination of pH was 0.25 for pH values ranging from 3.79 to 4.64; the estimated standard deviation for specific conductance was 4.6 microsiemens/cm at 25 C for specific-conductance values ranging from 10.4 to 59.0 microsiemens/cm at 25 C. Performance-audit samples with known analyte concentrations were prepared by the U.S.G.S.and distributed to the National Atmospheric Deposition Program 's Central Analytical Laboratory. The differences between the National Atmospheric Deposition Program and national Trends Network-reported analyte concentrations and known analyte concentrations were calculated, and the bias and precision were determined. For 1983, concentrations of calcium, magnesium, sodium, and chloride were biased at the 99% confidence limit; concentrations of potassium and sulfate were unbiased at the 99% confidence limit. Four analytical laboratories routinely analyzing precipitation were evaluated in their analysis of identical natural- and simulated precipitation samples. Analyte bias for each laboratory was examined using analysis of variance coupled with Duncan 's multiple-range test on data produced by these laboratories, from the analysis of identical simulated-precipitation samples. Analyte precision for each laboratory has been estimated by calculating a pooled variance for each analyte. Interlaboratory comparability results may be used to normalize natural-precipitation chemistry data obtained from two or more of these laboratories. (Author 's abstract)
Predictive modelling of flow in a two-dimensional intermediate-scale, heterogeneous porous media
Barth, Gilbert R.; Hill, M.C.; Illangasekare, T.H.; Rajaram, H.
2000-01-01
To better understand the role of sedimentary structures in flow through porous media, and to determine how small-scale laboratory-measured values of hydraulic conductivity relate to in situ values this work deterministically examines flow through simple, artificial structures constructed for a series of intermediate-scale (10 m long), two-dimensional, heterogeneous, laboratory experiments. Nonlinear regression was used to determine optimal values of in situ hydraulic conductivity, which were compared to laboratory-measured values. Despite explicit numerical representation of the heterogeneity, the optimized values were generally greater than the laboratory-measured values. Discrepancies between measured and optimal values varied depending on the sand sieve size, but their contribution to error in the predicted flow was fairly consistent for all sands. Results indicate that, even under these controlled circumstances, laboratory-measured values of hydraulic conductivity need to be applied to models cautiously.To better understand the role of sedimentary structures in flow through porous media, and to determine how small-scale laboratory-measured values of hydraulic conductivity relate to in situ values this work deterministically examines flow through simple, artificial structures constructed for a series of intermediate-scale (10 m long), two-dimensional, heterogeneous, laboratory experiments. Nonlinear regression was used to determine optimal values of in situ hydraulic conductivity, which were compared to laboratory-measured values. Despite explicit numerical representation of the heterogeneity, the optimized values were generally greater than the laboratory-measured values. Discrepancies between measured and optimal values varied depending on the sand sieve size, but their contribution to error in the predicted flow was fairly consistent for all sands. Results indicate that, even under these controlled circumstances, laboratory-measured values of hydraulic conductivity need to be applied to models cautiously.
Benyounes, Nadia; Lang, Sylvie; Gout, Olivier; Ancédy, Yann; Etienney, Arnaud; Cohen, Ariel
2016-10-01
Transthoracic echocardiography is the most commonly used tool for the detection of left ventricular wall motion (LVWM) abnormalities using "naked eye evaluation". This subjective and operator-dependent technique requires a high level of clinical training and experience. Two-dimensional speckle-tracking echocardiography (2D-STE), which is less operator-dependent, has been proposed for this purpose. However, the role of on-line segmental longitudinal peak systolic strain (LPSS) values in the prediction of LVWM has not been fully evaluated. To test segmental LPSS for predicting LVWM abnormalities in routine echocardiography laboratory practice. LVWM was evaluated by an experienced cardiologist, during routine practice, in 620 patients; segmental LPSS values were then calculated. In this work, reflecting real life, 99.6% of segments were successfully tracked. Mean (95% confidence interval [CI]) segmental LPSS values for normal basal (n=3409), mid (n=3468) and apical (n=3466) segments were -16.7% (-16.9% to -16.5%), -18.2% (-18.3% to -18.0%) and -21.1% (-21.3% to -20.9%), respectively. Mean (95% CI) segmental LPSS values for hypokinetic basal (n=114), mid (n=116) and apical (n=90) segments were -7.7% (-9.0% to -6.3%), -10.1% (-11.1% to -9.0%) and -9.3% (-10.5% to -8.1%), respectively. Mean (95% CI) segmental LPSS values for akinetic basal (n=128), mid (n=95) and apical (n=91) segments were -6.6% (-8.0% to -5.1%), -6.1% (-7.7% to -4.6%) and -4.2% (-5.4% to -3.0%), respectively. LPSS allowed the differentiation between normal and abnormal segments at basal, mid and apical levels. An LPSS value≥-12% detected abnormal segmental motion with a sensitivity of 78% for basal, 70% for mid and 82% for apical segments. Segmental LPSS values may help to differentiate between normal and abnormal left ventricular segments. Copyright © 2016 Elsevier Masson SAS. All rights reserved.
Unreliability of classic provocative tests for the diagnosis of growth hormone deficiency.
Mazzola, A; Meazza, C; Travaglino, P; Pagani, S; Frattini, D; Bozzola, E; Corneli, G; Aimaretti, G; Bozzola, M
2008-02-01
In this study we investigated 9 prepubertal children with blunted GH response to classic pharmacological stimuli in contrast with normal auxological evaluation. The children were followed to evaluate their growth velocity for a longer period before starting replacement GH therapy. To evaluate the pituitary reserve a supraphysiologic stimulus such as GHRH plus arginine was used. Serum GH levels were measured by a time-resolved immunofluorimetric assay before and after 1 microg/kg body weight iv injection of GHRH, while serum PRL, IGF-I, and insulin were evaluated only in basal conditions using an automatic immunometric assay. Out of 9 studied subjects, 7 underwent GHRH plus arginine administration and showed a normal GH response; the parents of the remaining 2 children refused the test. Normal serum levels of PRL, IGF-I, insulin, and a normal insulin sensitivity were observed in all children. After 1 yr, the growth rate in each patient was further improved and reached almost normal values. Our results further confirm that the decision to start replacement GH therapy should be based on both auxological parameters and laboratory findings. The GHRH plus arginine test appears to be useful to identify false GH deficiency in children showing a blunted GH response to classic stimuli in contrast with normal growth rate.
Sorokin, Victoria; Alkhoury, Razan; Al-Rawabdeh, Sura; Houston, Ronald H; Thornton, David; Kerlin, Bryce; O'Brien, Sarah; Baker, Peter; Boesel, Carl; Uddin, Minhaj; Yin, Han; Kahwash, Samir
This study sought to determine delta granule normal ranges for children and to validate methodology for the appropriate diagnosis of delta granule deficiency (storage pool disease) by using the whole-mount technique in electron microscopy. Specimens obtained from 40 healthy volunteers (2 months of age through 21 years old, 21 females and 19 males) were tested. Results showed dense granules/platelet (DG/Plt) ranged from 1.78 to 5.25. The 5th percentile was 1.96 DG/Plt with an overall mean ± SEM 3.07 ± 0.12 DG/Plt. In comparison, a previously published lower cutoff value, 3.68 DG/Plt, was significantly higher than the mean from our volunteers (P < 0.0001). We found no variability in dense granules/platelet based on race or sex and no significant variation by age subgroup. Pending wider studies, the value of 2 DG/Plt is a more appropriate lower limit of normal. In the absence of wider studies (in healthy volunteers and patients), laboratories should consider establishing their own reference ranges.
Use of labelled triolein, vitamin A, and D-xylose in the diagnosis of malabsorption 1
Wormsley, K. G.
1963-01-01
This paper discusses the type of results given by a group of test procedures used in the study of small intestinal dysfunction. While the chemical estimation of faecal fat remains the most valuable criterion for the laboratory detection of malabsorption, the occurrence of abnormal faecal or blood radioactivity also denotes the presence of malabsorption, although some patients with staetorrhoea appear to `absorb' labelled triolein normally. Analysis of data from the other tests shows that steatorrhoea is not necessarily present in patients who give abnormal results and that the presence of malabsorption does not preclude a normal capacity for handling the test substances. These reservations impair the value of the vitamin A and xylose `tolerance' tests and serum carotene levels as screening procedures for the determination of malabsorption states. On the other hand, these tests show patterns of results which are useful in differentiating idiopathic from secondary steatorrhoea, since patients with secondary malabsorption often handle one or more of these test substances normally. PMID:14058268
Mixing induced by a propagating normal mode in long term experiments
NASA Astrophysics Data System (ADS)
Dossmann, Yvan; Pollet, Florence; Odier, Philippe; Dauxois, Thierry
2017-04-01
The energy pathways from propagating internal waves to the scales of irreversible mixing in the ocean are numerous. The triadic resonant instability (TRI) is an intrinsic destabilization process that can lead to mixing away from topographies. It consists in the destabilization of a primary internal wave generation leading to the radiation of two secondary waves of lower frequencies and different wave vectors. In the process, internal wave energy is carried down to smaller scales. A previous study focused on the assessment of instantaneous turbulent fluxes fields associated with the TRI process in laboratory experiments [1]. The present study investigates the integrated impact of mixing processes induced by a propagative normal mode over long term experiments using a similar setup. Configurations for which the TRI process is either favored or inhibited are tackled. Optical measurements using the light attenuation technique allow to follow the internal waves dynamics and the evolution of the density profile between two runs of one hour typical duration. The horizontally averaged turbulent diffusivity Kt(z) and the mixing efficiency Γ are assessed. One finds values up to Kt = 10-6 m2/s and Γ = 11 %, with slightly larger values in the presence of TRI. The maximum value for Kt is measured at the position(s) of the maximum shear normal mode shear for both normal modes 1 and 2. The development of staircases in the density profile is observed after several hours of forcing. This mechanism can be explained by Phillips' argument by which sharp interfaces can form due to vertical variations of the buoyancy flux. The staircases are responsible for large variations in the vertical distribution of turbulent diffusivity. These results could help to refine parameterizations of the impact of low order normal modes in ocean mixing. Reference : [1] Dossmann et al. 2016, Mixing by internal waves quantified using combined PIV/PLIF technique, Experiments in Fluids, 57, 132.
Robbins, Rebecca J; Leonczak, Jadwiga; Li, Julia; Johnson, J Christopher; Collins, Tom; Kwik-Uribe, Catherine; Schmitz, Harold H
2012-01-01
An international collaborative study was conducted on an HPLC method with fluorescent detection (FLD) for the determination of flavanols and procyanidins in materials containing chocolate and cocoa. The sum of the oligomeric fractions with degree of polymerization 1-10 was the determined content value. Sample materials included dark and milk chocolates, cocoa powder, cocoa liquors, and cocoa extracts. The content ranged from approximately 2 to 500 mg/g (defatted basis). Thirteen laboratories representing commercial, industrial, and academic institutions in six countries participated in the study. Fourteen samples were sent as blind duplicates to the collaborators. Results from 12 laboratories yielded repeatability relative standard deviation (RSDr) values that were below 10% for all materials analyzed, ranging from 4.17 to 9.61%. The reproducibility relative standard deviation (RSD(R)) values ranged from 5.03 to 12.9% for samples containing 8.07 to 484.7 mg/g. In one sample containing a low content of flavanols and procyanidins (approximately 2 mg/g), the RSD(R) was 17.68%. Based on these results, the method is recommended for Official First Action for the determination of flavanols and procyanidins in chocolate, cocoa liquors, powder(s), and cocoa extracts.
Helmersson-Karlqvist, Johanna; Flodin, Mats; Havelka, Aleksandra Mandic; Xu, Xiao Yan; Larsson, Anders
2016-09-01
Serum/plasma albumin is an important and widely used laboratory marker and it is important that we measure albumin correctly without bias. We had indications that the immunoturbidimetric method on Cobas c 501 and the bromocresol purple (BCP) method on Architect 16000 differed, so we decided to study these methods more closely. A total of 1,951 patient requests with albumin measured with both the Architect BCP and Cobas immunoturbidimetric methods were extracted from the laboratory system. A comparison with fresh plasma samples was also performed that included immunoturbidimetric and BCP methods on Cobas c 501 and analysis of the international protein calibrator ERM-DA470k/IFCC. The median difference between the Abbott BCP and Roche immunoturbidimetric methods was 3.3 g/l and the Roche method overestimated ERM-DA470k/IFCC by 2.2 g/l. The Roche immunoturbidimetric method gave higher values than the Roche BCP method: y = 1.111x - 0.739, R² = 0.971. The Roche immunoturbidimetric albumin method gives clearly higher values than the Abbott and Roche BCP methods when analyzing fresh patient samples. The differences between the two methods were similar at normal and low albumin levels. © 2016 Wiley Periodicals, Inc.
Critical Value Reporting at Egyptian Laboratories.
Mosallam, Rasha; Ibrahim, Samaa Zenhom
2015-06-12
To examine critical value reporting policies and practices and to identify critical value ranges for selected common laboratory assays at inpatient division of laboratories of Alexandria hospitals. A cross-sectional descriptive study design was used. Subjects were from inpatient division of all laboratories of Alexandria hospitals (40 laboratories). Data were collected using a questionnaire composed of 4 sections. The first section explored hospital and laboratory characteristics. The second section assessed policies and procedures of critical value reporting. The third section explored the reporting process. The fourth section explored critical value ranges for selected common laboratory assays. Written procedure for reporting of critical values was present in 77.5% of laboratories and a comprehensive list of critical values in 72.55%. For laboratories having a critical value list, the number of tests in the list ranged from 7 to 40. Three-fifths of laboratories had a policy for assessing the timeliness of reporting and 3 quarters stated that the laboratory policy requires feedback (60.0% and 75.0%, respectively). The hospital laboratory physician was responsible for critical value reporting followed by the laboratory technician (75.0% and 50.0%, respectively). The call is received mainly by nurses and physicians ordering the test (67.5% and 55.0%, respectively) and the channel of reporting is mainly the telephone or through sending test report to the ward (67.5% and 50.0%, respectively). Wireless technologies are used in reporting in only 10.0% of hospitals. The cutoff limits for reporting different assays showed considerable interlaboratory variation. Critical value policies and practices showed interinstitutional variation with deficiencies in some reporting practices. Selection of critical assays for notification and setting the limits of notification exhibited wide variation as well.
Stricker, Reto; Eberhart, Raphael; Chevailler, Marie-Christine; Quinn, Frank A; Bischof, Paul; Stricker, René
2006-01-01
During a normal menstrual cycle, serum levels of luteinizing hormone (LH), follicle-stimulating hormone (FSH), estradiol, and progesterone can vary widely between cycles for the same woman, as well as between different woman. Reliable reference values based on the local population are important for correct interpretation of laboratory results. The purpose of our study was to determine detailed reference values for these hormones throughout the menstrual cycle using the Abbott ARCHITECT system. From 20 volunteers (age 20-36 years) with normal cycles and no use of oral contraceptives, samples were taken every day during their cycle. Volunteers received three vaginal ultrasound examinations (days 10 and 13, and 1 or 2 days after ovulation) to measure follicular and corpus luteum development. Hormone levels were measured using the corresponding ARCHITECT assay and were synchronized to the LH peak. Median, and 5th and 95th percentile values were determined for each day of the cycle, as well as for early follicular (days -15 to -6), late follicular (days -5 to -1), LH peak (day 0), early luteal (+1 to +4), mid-luteal (days +5 to +9), and late luteal (days +10 to +14) phases of the cycle. Based on our data, we were able to establish detailed reference values for LH, FSH, estradiol, and progesterone, which should aid in the interpretation of results for these reproductive hormones in a variety of circumstances.
The effect of blood cell count on coronary flow in patients with coronary slow flow phenomenon
Soylu, Korhan; Gulel, Okan; Yucel, Huriye; Yuksel, Serkan; Aksan, Gokhan; Soylu, Ayşegül İdil; Demircan, Sabri; Yılmaz, Özcan; Sahin, Mahmut
2014-01-01
Background and Objective: The coronary slow flow phenomenon (CSFP) is a coronary artery disease with a benign course, but its pathological mechanisms are not yet fully understood.The purpose of this controlled study was to investigate the cellular content of blood in patients diagnosed with CSFP and the relationship of this with coronary flow rates. Methods: Selective coronary angiographies of 3368 patients were analyzed to assess Thrombolysis in Myocardial Infarction (TIMI) frame count (TFC) values. Seventy eight of them had CSFP, and their demographic and laboratory findings were compared with 61 patients with normal coronary flow. Results: Patients’ demographic characteristics were similar in both groups. Mean corrected TFC (cTFC) values were significantly elevated in CSFP patients (p<0.001). Furthermore, hematocrit and hemoglobin values, and eosinophil and basophil counts of the CSFP patients were significantly elevated compared to the values obtained in the control group (p=0.005, p=0.047, p=0.001 and p=0.002, respectively). The increase observed in hematocrit and eosinophil levels showed significant correlations with increased TFC values (r=0.288 and r=0.217, respectively). Conclusion: Significant changes have been observed in the cellular composition of blood in patients diagnosed with CSFP as compared to the patients with normal coronary blood flow. The increases in hematocrit levels and in the eosinophil and basophil counts may have direct or indirect effects on the rate of coronary blood flow. PMID:25225502
Nasal continuous positive airway pressure treatment: current realities and future.
Berthon-Jones, M; Lawrence, S; Sullivan, C E; Grunstein, R
1996-11-01
Nasal continuous positive airway pressure (CPAP) is a highly effective treatment for obstructive sleep apnea syndrome. The apnea/hypopnea index (AHI) is reduced 10-fold, but the patient dropout rate is up to 30%, and usage is typically < 5 hours per night. Titration, designed to make the best trade-off between effectiveness and side effects, is expensive. Autotitrating devices make this trade-off on a minute-by-minute basis, potentially reducing mean pressure delivery, reducing side effects, and increasing compliance. The aim of this study was to test the effectiveness of the AutoSet self-adjusting nasal CPAP system (ResMed, Sydney, Australia) in eliminating obstructive events and normalizing the arousal index. Forty-five subjects (41 males and 4 females with AHI) values of > 20/hour were recruited, with written informed consent. Subjects slept for a diagnostic night, followed by a treatment night, in the laboratory, using the AutoSet system with full polysomnographic monitoring of respiratory and sleep variables. Arousals were scored using ASDA criteria. Hypopneas were scored when there was a 50% reduction in ventilation for > 10 seconds, associated with a 4% drop in oxygen saturation. For comparison, the ASDA arousal index in 16 normal subjects (without nasal CPAP) is provided. Results are given as mean +/- standard error of the mean. AHI was reduced from 55 +/- 3 to 1.5 +/- 0.35 events/hour (p < 0.0001). The arousal index was reduced from 65 +/- 3 to 18 +/- 2 events/hour (p < 0.0001), identical to the value in the 16 healthy normal subjects. There was a 158% +/- 21% increase in slow-wave sleep (p = 0.01) and a 186% +/- 27% increase in rapid eye movement sleep (p = 0.013). The AutoSet self-adjusting nasal CPAP system adequately treats obstructive sleep apnea syndrome on the first night under laboratory conditions.
Principles for high-quality, high-value testing.
Power, Michael; Fell, Greg; Wright, Michael
2013-02-01
A survey of doctors working in two large NHS hospitals identified over 120 laboratory tests, imaging investigations and investigational procedures that they considered not to be overused. A common suggestion in this survey was that more training was required. And, this prompted the development of a list of core principles for high-quality, high-value testing. The list can be used as a framework for training and as a reference source. The core principles are: (1) Base testing practices on the best available evidence. (2) Apply the evidence on test performance with careful judgement. (3) Test efficiently. (4) Consider the value (and affordability) of a test before requesting it. (5) Be aware of the downsides and drivers of overdiagnosis. (6) Confront uncertainties. (7) Be patient-centred in your approach. (8) Consider ethical issues. (9) Be aware of normal cognitive limitations and biases when testing. (10) Follow the 'knowledge journey' when teaching and learning these core principles.
The Submillimeter Wave Spectrum of Isotopic Methyl Cyanide
NASA Technical Reports Server (NTRS)
Pearson, J. C.; Mueller, H. S. P.
1996-01-01
The laboratory submillimeter wave rotational spectrum of the 13CH3CN, CH3C13CN, and CH3C15N isotopomers of methyl cyanide has been observed in natural abundance in the 294 to 607 GHz region. The maximum J and K values are 34 and 14, respectively. Fifteen additional CH3CN transitions up to K = 21 were also measured. The transitions of all four species are fitted to a symmetric top Hamiltonian, and the rotation and distortion constants are determined. The 14N quadrupole and spin rotation coupling constants are also calculated and presented. Suggested values for many other parameters, which could not be directly determined from the isotope spectra, are calculated from the normal species values and isotope relationships. The determined and calculated constants should predict the spectrum of the three isotopomers to well over 1 THz accurately enough for astronomical assignments.
Eckfeldt, John H; Karger, Amy B; Miller, W Greg; Rynders, Gregory P; Inker, Lesley A
2015-07-01
Cystatin C is becoming an increasingly popular biomarker for estimating glomerular filtration rate, and accurate measurements of cystatin C concentrations are necessary for accurate estimates of glomerular filtration rate. To assess the accuracy of cystatin C concentration measurements in laboratories participating in the College of American Pathologists CYS Survey. Two fresh frozen serum pools, the first from apparently healthy donors and the second from patients with chronic kidney disease, were prepared and distributed to laboratories participating in the CYS Survey along with the 2 usual processed human plasma samples. Target values were established for each pool by using 2 immunoassays and ERM DA471/IFCC international reference material. For the normal fresh frozen pool (ERM-DA471/IFCC-traceable target of 0.960 mg/L), the all-method mean (SD, % coefficient of variation [CV]) reported by all of the 123 reporting laboratories was 0.894 mg/L (0.128 mg/L, 14.3%). For the chronic kidney disease pool (ERM-DA471/IFCC-traceable target of 2.37 mg/L), the all-method mean (SD, %CV) was 2.258 mg/L (0.288 mg/L, 12.8%). There were substantial method-specific biases (mean milligram per liter reported for the normal pool was 0.780 for Siemens, 0.870 for Gentian, 0.967 for Roche, 1.061 for Diazyme, and 0.970 for other/not specified reagents; and mean milligram per liter reported for the chronic kidney disease pool was 2.052 for Siemens, 2.312 for Gentian, 2.247 for Roche, 2.909 for Diazyme, and 2.413 for other/not specified reagents). Manufacturers need to improve the accuracy of cystatin C measurement procedures if cystatin C is to achieve its full potential as a biomarker for estimating glomerular filtration rate.
Perich, C; Ricós, C; Alvarez, V; Biosca, C; Boned, B; Cava, F; Doménech, M V; Fernández-Calle, P; Fernández-Fernández, P; García-Lario, J V; Minchinela, J; Simón, M; Jansen, R
2014-05-15
Current external quality assurance schemes have been classified into six categories, according to their ability to verify the degree of standardization of the participating measurement procedures. SKML (Netherlands) is a Category 1 EQA scheme (commutable EQA materials with values assigned by reference methods), whereas SEQC (Spain) is a Category 5 scheme (replicate analyses of non-commutable materials with no values assigned by reference methods). The results obtained by a group of Spanish laboratories participating in a pilot study organized by SKML are examined, with the aim of pointing out the improvements over our current scheme that a Category 1 program could provide. Imprecision and bias are calculated for each analyte and laboratory, and compared with quality specifications derived from biological variation. Of the 26 analytes studied, 9 had results comparable with those from reference methods, and 10 analytes did not have comparable results. The remaining 7 analytes measured did not have available reference method values, and in these cases, comparison with the peer group showed comparable results. The reasons for disagreement in the second group can be summarized as: use of non-standard methods (IFCC without exogenous pyridoxal phosphate for AST and ALT, Jaffé kinetic at low-normal creatinine concentrations and with eGFR); non-commutability of the reference material used to assign values to the routine calibrator (calcium, magnesium and sodium); use of reference materials without established commutability instead of reference methods for AST and GGT, and lack of a systematic effort by manufacturers to harmonize results. Results obtained in this work demonstrate the important role of external quality assurance programs using commutable materials with values assigned by reference methods to correctly monitor the standardization of laboratory tests with consequent minimization of risk to patients. Copyright © 2013 Elsevier B.V. All rights reserved.
Frequency and Pathophysiology of Acute Liver Failure in Ornithine Transcarbamylase Deficiency (OTCD)
Laemmle, Alexander; Gallagher, Renata C.; Keogh, Adrian; Stricker, Tamar; Gautschi, Matthias; Nuoffer, Jean-Marc; Baumgartner, Matthias R.; Häberle, Johannes
2016-01-01
Background Acute liver failure (ALF) has been reported in ornithine transcarbamylase deficiency (OTCD) and other urea cycle disorders (UCD). The frequency of ALF in OTCD is not well-defined and the pathogenesis is not known. Aim To evaluate the prevalence of ALF in OTCD, we analyzed the Swiss patient cohort. Laboratory data from 37 individuals, 27 females and 10 males, diagnosed between 12/1991 and 03/2015, were reviewed for evidence of ALF. In parallel, we performed cell culture studies using human primary hepatocytes from a single patient treated with ammonium chloride in order to investigate the inhibitory potential of ammonia on hepatic protein synthesis. Results More than 50% of Swiss patients with OTCD had liver involvement with ALF at least once in the course of disease. Elevated levels of ammonia often correlated with (laboratory) coagulopathy as reflected by increased values for international normalized ratio (INR) and low levels of hepatic coagulation factors which did not respond to vitamin K. In contrast, liver transaminases remained normal in several cases despite massive hyperammonemia and liver involvement as assessed by pathological INR values. In our in vitro studies, treatment of human primary hepatocytes with ammonium chloride for 48 hours resulted in a reduction of albumin synthesis and secretion by approximately 40%. Conclusion In conclusion, ALF is a common complication of OTCD, which may not always lead to severe symptoms and may therefore be underdiagnosed. Cell culture experiments suggest an ammonia-induced inhibition of hepatic protein synthesis, thus providing a possible pathophysiological explanation for hyperammonemia-associated ALF. PMID:27070778
The theory of reference values: an unfinished symphony.
Siest, Gerard; Henny, Joseph; Gräsbeck, Ralph; Wilding, Peter; Petitclerc, Claude; Queraltó, Josep M; Hyltoft Petersen, Peter
2013-01-01
The history of the theory of reference values can be written as an unfinished symphony. The first movement, allegro con fuoco, played from 1960 to 1980: a mix of themes devoted to the study of biological variability (intra-, inter-individual, short- and long-term), preanalytical conditions, standardization of analytical methods, quality control, statistical tools for deriving reference limits, all of them complex variations developed on a central melody: the new concept of reference values that would replace the notion of normality whose definition was unclear. Additional contributions (multivariate reference values, use of reference limits from broad sets of patient data, drug interferences) conclude the movement on the variability of laboratory tests. The second movement, adagio, from 1980 to 2000, slowly develops and implements initial works. International and national recommendations were published by the IFCC-LM (International Federation of Clinical Chemistry and Laboratory Medicine) and scientific societies [French (SFBC), Spanish (SEQC), Scandinavian societies…]. Reference values are now topics of many textbooks and of several congresses, workshops, and round tables that are organized all over the world. Nowadays, reference values are part of current practice in all clinical laboratories, but not without difficulties, particularly for some laboratories to produce their own reference values and the unsuitability of the concept with respect to new technologies such as HPLC, GCMS, and PCR assays. Clinicians through consensus groups and practice guidelines have introduced their own tools, the decision limits, likelihood ratios and Reference Change Value (RCV), creating confusion among laboratorians and clinicians in substituting reference values and decision limits in laboratory reports. The rapid development of personalized medicine will eventually call for the use of individual reference values. The beginning of the second millennium is played allegro ma non-troppo from 2000 to 2012: the theory of reference values is back into fashion. The need to revise the concept is emerging. The manufacturers make a friendly pressure to facilitate the integration of Reference Intervals (RIs) in their technical documentation. Laboratorians are anxiously awaiting the solutions for what to do. The IFCC-LM creates Reference Intervals and Decision Limits Committee (C-RIDL) in 2005. Simultaneously, a joint working group IFCC-CLSI is created on the same topic. In 2008 the initial recommendations of IFCC-LM are revised and new guidelines are published by the Clinical and Laboratory Standards Institute (CLSI C28-A3). Fundamentals of the theory of reference values are not changed, but new avenues are explored: RIs transference, multicenter reference intervals, and a robust method for deriving RIs from small number of subjects. Concomitantly, other statistical methods are published such as bootstraps calculation and partitioning procedures. An alternative to recruiting healthy subjects proposes the use of biobanks conditional to the availability of controlled preanalytical conditions and of bioclinical data. The scope is also widening to include veterinary biology! During the early 2000s, several groups proposed the concept of 'Universal RIs' or 'Global RIs'. Still controversial, their applications await further investigations. The fourth movement, finale: beyond the methodological issues (statistical and analytical essentially), important questions remain unanswered. Do RIs intervene appropriately in medical decision-making? Are RIs really useful to the clinicians? Are evidence-based decision limits more appropriate? It should be appreciated that many laboratory tests represent a continuum that weakens the relevance of RIs. In addition, the boundaries between healthy and pathological states are shady areas influenced by many biological factors. In such a case the use of a single threshold is questionable. Wherever it will apply, individual reference values and reference change values have their place. A variation on an old theme! It is strange that in the period of personalized medicine (that is more stratified medicine), the concept of reference values which is based on stratification of homogeneous subgroups of healthy people could not be discussed and developed in conjunction with the stratification of sick patients. That is our message for the celebration of the 50th anniversary of Clinical Chemistry and Laboratory Medicine. Prospects are broad, enthusiasm is not lacking: much remains to be done, good luck for the new generations!
DOE Office of Scientific and Technical Information (OSTI.GOV)
Alterio, Daniela; Jereczek-Fossa, Barbara Alicja; University of Milan, Milan
2007-01-01
Purpose: To evaluate the incidence of thyroid disorders and dose distribution to the thyroid in patients treated with radiotherapy for head-and-neck carcinomas. Methods and Materials: A retrospective evaluation of data from 73 patients treated for head-and-neck cancers in our department was performed. Thyroid function was evaluated mainly by the measurement of thyrotropin (thyroid stimulating hormone [TSH]). A retrospective analysis of treatment plans was performed for 57 patients. Percentages of thyroid glandular volume absorbing 10, 30, and 50 Gy (V10, V30, and V50 respectively) were considered for statistical analysis. Results: A majority of patients (61%) had a normal thyroid function whereasmore » 19 patients (26%) had hypothyroidism. Mean thyroid volume was 30.39 cc. Point 3 (located at isthmus) absorbed lower doses compared with other points (p < 0.0001). Median values of V10, V30, and V50 were 92% (range, 57-100%), 75% (range, 28.5-100%), and 35% (range, 3-83%) respectively. Gender was associated with toxicity (presence of any kind of thyroid disorders) (p < 0.05), with females displaying higher levels of TSHr (relative TSH = patient's value/maximum value of the laboratory range) (p = 0.0005) and smaller thyroid volume (p 0.0012) compared with male population. TSHr values were associated with thyroid volume, and the presence of midline shielding block in the anterior field was associated with relative free thyroxine (FT4r = patient's value/maximum value of the laboratory range) values. Conclusions: Gender and thyroid volume seem to play an important role in the occurrence of thyroid toxicity, but further studies on dose-effect relationship for radiotherapy-induced thyroid toxicity are needed.« less
Juhel-Gaugain, M; McEvoy, J D; VanGinkel, L A
2000-12-01
The experimental design of a material certification programme is described. The matrix reference materials (RMs) comprised chlortetracycline (CTC)-containing and CTC-free lyophilised porcine liver, kidney and muscle produced under the European Commission's Standards Measurements and Testing (SMT) programme. The aim of the certification programme was to determine accurately and precisely the concentration of CTC and 4-epi-chlortetracycline (epi-CTC) contained in the RMs. A multi-laboratory approach was used to certify analyte concentrations. Participants (n = 19) were instructed to strictly adhere to previously established guidelines. Following the examination of analytical performance criteria, statistical manipulation of results submitted by 13 laboratories, (6 withdrew) allowed an estimate to be made of the true value of the analyte content. The Nalimov test was used for detection of outlying results. The Cochran and Bartlett tests were employed for testing the homogeneity of variances. The normality of results distribution was tested according to the Kolmogorov-Smirnov-Lilliefors test. One-way analysis of variance (ANOVA) was employed to calculate the within and between-laboratory standard deviations, the overall mean and confidence interval for the CTC and epi-CTC content of each of the RMs. Certified values were within or very close to the target concentration ranges specified in the SMT contract. These studies have demonstrated the successful production and certification of CTC-containing and CTC-free porcine RMs.
The Classic Approach to Diagnosis of Vulvovaginitis: A Critical Analysis
Lakovsky, Yaniv; Lavi, Idit; Bar-Am, Amiram; Abramovici, Haim
2001-01-01
Objective: To correlate the symptoms, signs and clinical diagnosis in women with vaginal discharge, based on the combined weight of the character of the vaginal discharge and bedside tests, with the laboratory diagnosis. Methods: Women presenting consecutively to the women's health center with vaginal discharge were interviewed and examined for assessment of the quantity and color of the discharge. One drop of the material was then examined for pH and the whiff test was done; a wet mount in saline and in 10% KOH was examined microscopically. The clinical diagnosis was based on the results of these assessments. Gram stain and cultures of the discharge were sent to the microbiology laboratory. Results: One hundred and fifty-threewomen with vaginal discharge with a clinical diagnosis of vulvovaginitis participated in the study. Fifty-five (35.9%) had normal flora and the other 98 (64.1%) had true infectious vulvovaginitis (k agreement = 18%). According to the laboratory, the principal infectious micro-organism causing the vulvovaginitis was Candida species. Candida infection was associated with pH levels of less than 4.5 (p < 0.0001, odds ratio = 4.74, 95% confidence interval: 2.35–9.5, positive predictive value 68.4%). The whiff test was positive in only a small percentage of bacterial vaginosis (BV) (p = not significant (NS)). Clue cells were documented in 53.3% of patients with a laboratory diagnosis of BV (p < 0.02, positive predictive value 26.7%). Conclusions: The current approach to the diagnosis of vulvovaginitis should be further studied. The classical and time-consuming assessments were shown not to be reliable diagnostic measures. PMID:11495550
Berg, Jan; Kottwitz, Jan; Baltensperger, Nora; Kissel, Christine K; Lovrinovic, Marina; Mehra, Tarun; Scherff, Frank; Schmied, Christian; Templin, Christian; Lüscher, Thomas F; Heidecker, Bettina; Manka, Robert
2017-11-01
There is a major unmet need to identify high-risk patients in myocarditis. Although decreasing cardiac and inflammatory markers are commonly interpreted as resolving myocarditis, this assumption has not been confirmed as of today. We sought to evaluate whether routine laboratory parameters at diagnosis predict dynamic of late gadolinium enhancement (LGE) as persistent LGE has been shown to be a risk marker in myocarditis. Myocarditis was diagnosed based on clinical presentation, high-sensitivity troponin T, and cardiac magnetic resonance imaging, after exclusion of obstructive coronary artery disease by angiography. Cardiac magnetic resonance imaging was repeated at 3 months. LGE extent was analyzed with the software GT Volume. Change in LGE >20% was considered significant. Investigated cardiac and inflammatory markers included high-sensitivity troponin T, creatine kinase, myoglobin, N-terminal B-type natriuretic peptide, C-reactive protein, and leukocyte count. Twenty-four patients were enrolled. Absolute levels of cardiac enzymes and inflammatory markers at baseline did not predict change in LGE at 3 months. Cardiac and inflammatory markers had normalized in 21 patients (88%). LGE significantly improved in 16 patients (67%); however, it persisted to a lesser degree in 17 of them (71%) and increased in a small percentage (21%) despite normalization of cardiac enzymes. This is the first study reporting that cardiac enzymes and inflammatory parameters do not sufficiently reflect LGE in myocarditis. Although a majority of patients with normalizing laboratory markers experienced improved LGE, in a small percentage LGE worsened. These data suggest that cardiac magnetic resonance imaging might add value to currently existing diagnostic tools for risk assessment in myocarditis. © 2017 American Heart Association, Inc.
Untangling the etiology of ascites.
Lopez-Molina, Michael; Shiani, Ashok V; Oller, Kellee L
2015-04-06
Amyloidosis is a systemic disease known to affect a vast range of organs, including the liver, heart, and kidney. When infiltrating the liver, amyloidosis typically does not present with cirrhosis. Typical presentation includes hepatomegaly with some mild laboratory abnormalities. A 72-year-old man presented with a 2-week history of worsening abdominal, scrotal, and extremity swelling. He endorsed melanotic stools and intermittent dizziness with a 10-pound weight gain. Vitals revealed a blood pressure of 82/57 mmHg and a pulse of 83 beats/min with positive orthostatic changes. Mild bibasilar crackles were noted. His abdomen was moderately distended with a fluid wave present, but no hepatosplenomegaly was noted. He displayed anasarca with significant extremity and scrotal edema, but no jaundice, telangiectasias, or other stigmata of chronic liver disease were present. Liver function tests demonstrated a total bilirubin of 1.5 mg/dL (normal value: 0.2-1.2 mg/dL), AST 111 IU/L (normal value 5-34 IU/L), ALT 51 IU/L (normal value 5-55 IU/L), and GGT 583 U/L (12-64 U/L). Alkaline phosphatase was 645 U/L (40-150 U/L). Analysis of peritoneal fluid was consistent with portal hypertension due to liver disease. Given an atypical presentation of cirrhosis with unclear etiology, a biopsy was performed and revealed amyloid deposition. Liver disease can be due to various etiologies, many of which can present ambiguously. Although the most typical etiologies have been well defined, we present a case of an atypical presentation of hepatic amyloidosis discovered in a patient with ascites and without typical hepatomegaly.
Normalized vertical ice mass flux profiles from vertically pointing 8-mm-wavelength Doppler radar
NASA Technical Reports Server (NTRS)
Orr, Brad W.; Kropfli, Robert A.
1993-01-01
During the FIRE 2 (First International Satellite Cloud Climatology Project Regional Experiment) project, NOAA's Wave Propagation Laboratory (WPL) operated its 8-mm wavelength Doppler radar extensively in the vertically pointing mode. This allowed for the calculation of a number of important cirrus cloud parameters, including cloud boundary statistics, cloud particle characteristic sizes and concentrations, and ice mass content (imc). The flux of imc, or, alternatively, ice mass flux (imf), is also an important parameter of a cirrus cloud system. Ice mass flux is important in the vertical redistribution of water substance and thus, in part, determines the cloud evolution. It is important for the development of cloud parameterizations to be able to define the essential physical characteristics of large populations of clouds in the simplest possible way. One method would be to normalize profiles of observed cloud properties, such as those mentioned above, in ways similar to those used in the convective boundary layer. The height then scales from 0.0 at cloud base to 1.0 at cloud top, and the measured cloud parameter scales by its maximum value so that all normalized profiles have 1.0 as their maximum value. The goal is that there will be a 'universal' shape to profiles of the normalized data. This idea was applied to estimates of imf calculated from data obtained by the WPL cloud radar during FIRE II. Other quantities such as median particle diameter, concentration, and ice mass content can also be estimated with this radar, and we expect to also examine normalized profiles of these quantities in time for the 1993 FIRE II meeting.
Surface emissivity of a reinforced carbon composite material with an oxidation-inhibiting coating
NASA Technical Reports Server (NTRS)
Wakefield, R. M.
1973-01-01
Total effective emissivity and spectral emissivity over the wavelength range of 0.65 to 6.3 microns were determined for temperatures from 1300 t0 2250 deg K. A multi channel radiometer was used in the arcjet and laboratory tests. The black-body-hole method was used to independently check radiometer results. The results show the silicon-carbide coated reinforced carbon composite material is a nongray radiator. The total effective emissivity and the spectral emissivity at 0.65 micron both decreased with increasing temperature, respectively, from approximately 0.8 to 0.6, and from 0.4 to 0.25, over the temperature range. The emissivity values were the same when the sample was viewed normal to the surface or at a 45 deg angle. Recommended emissivity values are presented.
Helin, Tuukka A; Pakkanen, Anja; Lassila, Riitta; Joutsi-Korhonen, Lotta
2013-05-01
Laboratory tests to assess novel oral anticoagulants (NOACs) are under evaluation. Routine monitoring is unnecessary, but under special circumstances bioactivity assessment becomes crucial. We analyzed the effects of NOACs on coagulation tests and the availability of specific assays at different laboratories. Plasma samples spiked with dabigatran (Dabi; 120 and 300 μg/L) or rivaroxaban (Riva; 60, 146, and 305 μg/L) were sent to 115 and 38 European laboratories, respectively. International normalized ratio (INR) and activated partial thromboplastin time (APTT) were analyzed for all samples; thrombin time (TT) was analyzed specifically for Dabi and calibrated anti-activated factor X (anti-Xa) activity for Riva. We compared the results with patient samples. Results of Dabi samples were reported by 73 laboratories (13 INR and 9 APTT reagents) and Riva samples by 22 laboratories (5 INR and 4 APTT reagents). Both NOACs increased INR values; the increase was modest, albeit larger, for Dabi, with higher CV, especially with Quick (vs Owren) methods. Both NOACs dose-dependently prolonged the APTT. Again, the prolongation and CVs were larger for Dabi. The INR and APTT results varied reagent-dependently (P < 0.005), with less prolongation in patient samples. TT results (Dabi) and calibrated anti-Xa results (Riva) were reported by only 11 and 8 laboratories, respectively. The screening tests INR and APTT are suboptimal in assessing NOACs, having high reagent dependence and low sensitivity and specificity. They may provide information, if laboratories recognize their limitations. The variation will likely increase and the sensitivity differ in clinical samples. Specific assays measure NOACs accurately; however, few laboratories applied them. © 2013 American Association for Clinical Chemistry.
Congenital syphilis in neonates with nonreactive nontreponemal test results.
Wozniak, P S; Cantey, J B; Zeray, F; Leos, N K; Sheffield, J S; Wendel, G D; Sánchez, P J
2017-10-01
Infants whose mothers had syphilis during pregnancy were studied to determine how often exposed newborns with normal physical examinations and nonreactive nontreponemal serologic tests had abnormal laboratory or radiographic studies. Retrospective analysis of prospectively collected data from infants born to mothers with syphilis and had a normal examination and a nonreactive nontreponemal test. Some infants had IgM immunoblotting, PCR testing or rabbit infectivity testing (RIT) performed. From 1984 to 2002, 115 infants had a nonreactive serum Venereal Disease Research Laboratory (VDRL)/rapid plasma reagin (RPR) test and a normal physical examination at birth. Among 87 infants born to mothers who had untreated syphilis, 4 had a positive serum IgM immunoblot or PCR test, but none had spirochetes recovered by RIT. Two infants had anemia, one had an elevated serum alanine aminotransferase concentration and one with Down's syndrome had direct hyperbilirubinemia. Among 14 infants born to mothers treated <4 weeks before delivery, none had abnormal laboratory or radiographic tests, although 1 of 11 had a reactive serum IgM immunoblot. Among 14 infants born to mothers treated ⩾4 weeks before delivery, none had abnormal laboratory or radiographic tests. Newborns with normal physical examination and nonreactive nontreponemal test results are unlikely to have abnormalities detected on conventional laboratory and radiographic testing.
Minton, J P; Rossio, J L; Dixon, B; Dodd, M C
1976-01-01
Corynebacterium parvum, a Gram-positive anaerobic bacillus thought to be a strong immunological stimulant, has been shown to decrease tumour growth and prolong survival in patients with metastatic disease. Study of the effect of a single injection of a strain of C. parvum (CN. 6134) in six patients with stage IV metastatic breast cancer is reported. Results of laboratory tests to judge the physical and immunological effects of the drug infusion 24 hr post-treatment and weekly thereafter for 3 weeks are evaluated. Within 24 hr after C. parvum administration, most patients experienced fever and nausea. Blood counts and differential counts exhibited increased values 24 hr after treatment with a strong shift to the left. Lymphocyte and monocyte counts were greatly depressed at 24 hr. T-cell numbers in peripheral blood did not appear to be altered, but the picture with regard to B cells was less clear. Normal count was recovered by day 8. It appears that intravenous administration of C. parvum produces a temporary marked immunological depression which returns to essentially normal values in 8 days. The return to normal may be accompanied by resolution of the endotoxin-like syndrome of side-effects. Further study of patients receiving this therapeutic agent is important to detect enhancement of the anti-tumour immunological response precipitated. PMID:1084821
Nagami, Glenn T.
2013-01-01
Summary The serum anion gap has been utilized to identify errors in the measurement of electrolytes, to detect paraproteins, and, most relevant to the nephrologist, to evaluate patients with suspected acid-base disorders. In regard to the latter purpose, traditionally an increased anion gap is identified when it exceeds the upper limit of normal for a particular clinical laboratory measurement. However, because there is a wide range of normal values (often 8–10 mEq/L), an increase in anion concentration can be present in the absence of an increased anion gap. In addition, the type of retained anion can affect the magnitude of the increase in anion gap relative to change in serum [HCO3−] being greater with lactic acidosis compared with ketoacidosis. This review examines the methods of calculation of the serum anion gap in textbooks and published literature, the effect of perturbations other than changes in acid-base balance, and its effectiveness in identifying mild and more severe disturbances in acid-base balance. Limitations of the present methods of determining the normal anion gap and change in the anion gap are highlighted. The possibility of identifying the baseline value for individuals to optimize the use of the calculation in the detection of metabolic acidosis is suggested. PMID:23833313
Experimental investigation of internal tides generated by finite-height topography
NASA Astrophysics Data System (ADS)
Wang, Shuya; Chen, Xu; Wang, Jinhu; Meng, Jing
2018-06-01
Internal tides generated by finite-height topography are investigated in the laboratory, and the particle image velocimetry (PIV) technique is applied to measure the velocity fields. The energy, energy flux, and vertical mode structure of the internal tides are calculated and analyzed. The experimental results indicate that the strength of the wave field is mainly affected by the normalized topography height. The rays radiated from the taller topography are wider than those radiated from the lower topography. Both the experimental and theoretical results indicate that the normalized energy and energy flux of the internal tides are mainly determined by the normalized topography height, and the increase of the two quantities follows a quadratic function, and they almost remain unchanged with different normalized frequencies except for higher frequency. The percentage of energy for mode-1 and mode-2 internal tides is determined not only by frequency but also by topography height. In addition, an "inherent normalized frequency" is observed in the experiment, at which the percentage of energy for mode 1 and mode 2 does not vary with topography height. The decay rate of internal tide energy in the near field and far field is also estimated, with average values of 36.5 and 7.5%, respectively.
Giechaskiel, Barouch; Vlachos, Theodoros; Riccobono, Francesco; Forni, Fausto; Colombo, Rinaldo; Montigny, Francois; Le-Lijour, Philippe; Carriero, Massimo; Bonnel, Pierre; Weiss, Martin
2016-12-04
Vehicles are tested in controlled and relatively narrow laboratory conditions to determine their official emission values and reference fuel consumption. However, on the road, ambient and driving conditions can vary over a wide range, sometimes causing emissions to be higher than those measured in the laboratory. For this reason, the European Commission has developed a complementary Real-Driving Emissions (RDE) test procedure using the Portable Emissions Measurement Systems (PEMS) to verify gaseous pollutant and particle number emissions during a wide range of normal operating conditions on the road. This paper presents the newly-adopted RDE test procedure, differentiating six steps: 1) vehicle selection, 2) vehicle preparation, 3) trip design, 4) trip execution, 5) trip verification, and 6) calculation of emissions. Of these steps, vehicle preparation and trip execution are described in greater detail. Examples of trip verification and the calculations of emissions are given.
Remote sensing and laboratory techniques for monitoring ocean dumping
NASA Technical Reports Server (NTRS)
Ohlhorst, C. W.; Johnson, R. W.; Meyer, E. R.
1977-01-01
Results of field experiments conducted in the Atlantic Coastal Zone indicate that plumes resulting from ocean dumping of acid waste and sewage sludge have distinguishable spectral characteristics when the radiance of the pollutant is normalized (ratioed to) background ocean water. Acid waste spectra peak between 550-650 nm while sewage sludge spectra have peak values at wavelengths of about 700 nm or greater. Results indicate that identification of acid waste and sewage sludge plumes may be independent of geographical location in the Atlantic Coastal Zone. Radiance ratio curves obtained in the laboratory qualitatively agree with those obtained from field experiments. Results from the July 25, 1977, Galveston Deep Ocean Dump Site experiment show the radiance ratio curve of the biodigested industrial waste to be fairly flat and similar to the radiance ratio curves of sewage sludge line dumps and sewage sludge spot dumps that have been in the water for several hours.
NASA Technical Reports Server (NTRS)
Trolinger, J. D.; Lal, R. B.; Batra, A. K.; Mcintosh, D.
1991-01-01
The first International Microgravity Laboratory (IML-1), scheduled for spaceflight in early 1992 includes a crystal-growth-from-solution experiment which is equipped with an array of optical diagnostics instrumentation which includes transmission and reflection holography, tomography, schlieren, and particle image displacement velocimetry. During the course of preparation for this spaceflight experiment we have performed both experimentation and analysis for each of these diagnostics. In this paper we describe the work performed in the development of holographic particle image displacement velocimetry for microgravity application which will be employed primarily to observe and quantify minute convective currents in the Spacelab environment and also to measure the value of g. Additionally, the experiment offers a unique opportunity to examine physical phenomena which are normally negligible and not observable. A preliminary analysis of the motion of particles in fluid was performed and supporting experiments were carried out. The results of the analysis and the experiments are reported.
Giechaskiel, Barouch; Vlachos, Theodoros; Riccobono, Francesco; Forni, Fausto; Colombo, Rinaldo; Montigny, Francois; Le-Lijour, Philippe; Carriero, Massimo; Bonnel, Pierre; Weiss, Martin
2016-01-01
Vehicles are tested in controlled and relatively narrow laboratory conditions to determine their official emission values and reference fuel consumption. However, on the road, ambient and driving conditions can vary over a wide range, sometimes causing emissions to be higher than those measured in the laboratory. For this reason, the European Commission has developed a complementary Real-Driving Emissions (RDE) test procedure using the Portable Emissions Measurement Systems (PEMS) to verify gaseous pollutant and particle number emissions during a wide range of normal operating conditions on the road. This paper presents the newly-adopted RDE test procedure, differentiating six steps: 1) vehicle selection, 2) vehicle preparation, 3) trip design, 4) trip execution, 5) trip verification, and 6) calculation of emissions. Of these steps, vehicle preparation and trip execution are described in greater detail. Examples of trip verification and the calculations of emissions are given. PMID:28060306
Omoruyi, Felix O; Mustafa, Gul M; Okorodudu, Anthony O; Petersen, John R
2012-03-22
The evaluation of microalbumin, creatinine and albumin-creatinine ratio is very important in patients with diabetes for the early detection of kidney disease and the identification of patients at risk for complications from diabetes or hypertension. A total of 88 spot urine samples previously analyzed using the Vitros 5,1 FS (creatinine) and Beckman Coulter Immage (microalbumin) located in the central laboratory and having microalbumin and creatinine values within the Afinion and DCA Vantage reportable ranges were run on 2 point of care (POC) instruments (Siemens DCA Vantage and Axis-Shield Afinion). The mean values for the DCA Vantage were: 42.6 mg/l for albumin, 10.3 mol/l for creatinine, and 5.4 mg/mol for ACR. For the Afinion AS100, the mean values were: 48.5mg/l for albumin, 9.5 mol/l for creatinine, and 6.7 mg/mol for ACR. The mean values obtained for CL were: 40.8 mg/l for albumin, 10.0 mol/l for creatinine, and 5.4 mg/mol for ACR. All POC analyzers showed good correlation to the central laboratory tests for microalbumin, creatinine and albumin creatinine ratio (ACR) for Afinion (R(2)=0.954, 0.974, and 0.964, respectively) and DCA Vantage (R(2)=0.989, 0.987, and 0.991, respectively). With the exception of the DCA Vantage ACR (p=0.53), the levels of microalbumin, creatinine and ACR obtained for the Afinion and DCA Vantage instruments as compared to the CL were statistically different (p<0.05). The inter and intraday imprecision for both POC instruments was <2.9% and total imprecision <8.7%. The 2 instruments evaluated in this study were in good agreement with the quantitative laboratory results and thus can be used for microalbumin, creatinine and ACR assays at the POC. However, facilities using Afinion will have to use different normal range for ACR. Copyright © 2011 Elsevier B.V. All rights reserved.
Transient hyperthyroidism after surgery for secondary hyperparathyroidism: a common problem.
Rudofsky, Gottfried; Tsioga, M; Reismann, P; Leowardi, C; Kopf, S; Grafe, I A; Nawroth, P P; Isermann, B
2011-08-08
Postoperative hyperthyroidism occurs in approximately one third of patients following parathyroidectomy due to primary hyperparathyroidism (PHP), but has only rarely been described in secondary hyperparathyroidism (SHP). The frequency, course, and laboratory markers of postoperative hyperthyroidism in SHP remain unknown. Our purpose was to evaluate the frequency and the clinical course of postoperative hyperthyroidism following surgery of SHP and to determine the diagnostic value of thyroglobulin in this setting. A total of 40 patients undergoing parathyroidectomy because of SHP were included in this study. Thyroid stimulating hormone (TSH), free triiodothyronine (fT3), free thyroxine (fT4), and thyroglobulin (Tg) were determined one day before and on day 1, 3, 5, 10, and 40 after surgery. At each of these visits patients were clinically evaluated for signs or symptoms of hyperthyroidism. Biochemical evidence of hyperthyroidism was evident in 77% of patients postoperatively despite of preoperatively normal serum levels. TSH dropped from 1.18 ± 0.06mU/L to 0.15 ± 0.07mU/L (p = 0.0015). Free triiodothyronine (fT3) and fT4 levels increased from 2.86 ± 0.02ng/L and 10.32 ± 0.13ng/L, respectively, to their maximum of 4.83 ± 0.17ng/L and 19.35 ± 0.58ng/L, respectively. Thyroglobulin levels rose from 3.8 ± 0.8ng/mL to 111.8 ± 45.3ng/mL (p<0.001). At day 40 all thyroid related laboratory values were within normal range. Correlation analysis of postoperative values revealed significant correlations for lowest TSH (r = -0.32; p = 0.038), and highest fT3 (r = 0.55; p<0.001) and fT4 levels (r = 0.67; p<0.001) with Tg. Transient hyperthyroidism is frequent after parathyroidectomy for SHP with Tg being a suitable marker. Awareness of this self-limiting disorder is important to avoid inappropriate and potentially harmful treatment.
Transient hyperthyroidism after surgery for secondary hyperparathyroidism: a common problem
2011-01-01
Background Postoperative hyperthyroidism occurs in approximately one third of patients following parathyroidectomy due to primary hyperparathyroidism (PHP), but has only rarely been described in secondary hyperparathyroidism (SHP). The frequency, course, and laboratory markers of postoperative hyperthyroidism in SHP remain unknown. Our purpose was to evaluate the frequency and the clinical course of postoperative hypcrthyroidism following surgery of SHP and to determine the diagnostic value of thyroglobulin in this setting. Material and Methods A total of 40 patients undergoing parathyroidectomy because of SHP were included in this study. Thyroid stimulating hormone (TSH), free triiodothyronine (fT3), free thyroxine (fl4), and thyroglobulin (Tg) were determined one day before and on day 1, 3, 5, 10, and 40 after surgery. At each of these visits patients were clinically evaluated for signs or symptoms of hyperthyroidism. Results Biochemical evidence of hyperthyroidism was evident in 77% of patients postoperatively despite of preoperatively normal serum levels. TSH dropped from 1.18 ± 0.06mU/L to 0.15 ± 0.07mU/L (p = 0.0015). Free triiodothyronine (fT3) and fT4 levels increased from 2.86 ± 0.02ng/L and 10.32 ± 0.13ng/L, respectively, to their maximum of 4.83 ± 0.17ng/L and 19.35 ± 0.58ng/L, respectively. Thyroglobulin levels rose from 3.8 ± 0.8ng/mL to 111.8 ± 45.3ng/mL (p < 0.001). At day 40 all thyroid related laboratory values were within normal range. Correlation analysis of postoperative values revealed significant correlations for lowest TSH (r = -0.32; p = 0.038), and highest fT3 (r = 0.55; p < 0.001) and fT4 levels (r = 0.67; p < 0.001) with Tg. Conclusion Transient hyperthyroidism is frequent after parathyroidectomy for SHP with Tg being a suitable marker. Awareness of this self-limiting disorder is important to avoid inappropriate and potentially harmful treatment. PMID:21813380
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chiaro, PJ
The Environmental Effects Laboratory of the Engineering Science and Technology Division of Oak Ridge National Laboratory performed a series of tests to further evaluate and characterize the radiological response of a ''Cricket'' radiation detection system. The Cricket, manufactured by Rad/Comm Systems Corporation of Ontario, Canada, is designed to detect radioactive material that may be contained in scrap metal. The Cricket's detection unit is designed to be mounted to the base of a grappler, allowing it to monitor material while the material is being held by the grappler tines. The Cricket was tested for background stability, energy response, spherical response, surfacemore » uniformity, angular dependence, and alarm actuation. Some of these tests were repeated from a prior test of a Cricket at the Environmental Effects Laboratory as reported in ORNL/TM-2002/94. Routine environmental tests--normal temperature and relatively humidity--were also performed as part of this testing process. Overall, the Cricket performed well during the testing process. The design of the instrument and the inherent photon energy of the radionuclides had some affect on portions of the tests but do not detract from the value-added benefits of the Cricket's detection capabilities.« less
The Sixth SeaWiFS/SIMBIOS Intercalibration Round-Robin Experiment (SIRREX-6)
NASA Technical Reports Server (NTRS)
Riley, Thomas; Bailey, Sean
1998-01-01
For the sixth Sea-Viewing Wide Field-of-View Sensor (SeaWiFS) Intercalibration Round-Robin Experiment (SIRREX-6), NASA personnel carried the same four Satlantic in-water radiometers to nine separate laboratories and calibrated them. Two of the sensors were seven-channel radiance heads and two were seven-channel irradiance heads. The calibration and data reduction procedures used at each site followed that laboratory's normal procedures. The reference lamps normally used for the calibration of these types of instruments by the various laboratories were also used for this experiment. NASA personnel processed the data to produce calibration parameters from the various laboratories
Teklu, Berhan M; Retta, Negussie; Van den Brink, Paul J
2016-08-01
The aims of the present study were to present a methodology for toxicity tests that can be used when analytical resources to verify the test concentrations are limited, and to evaluate whether the sensitivity of a limited number of Ethiopian species to pesticides differs from literature values for, mainly, temperate species. Acute toxicity tests were performed using three Ethiopian aquatic invertebrate species, one crustacean (Diaphanosoma brachyurum) and two insects (Anopheles pharoensis and Culex pipiens) and using the pesticides endosulfan and diazinon. All species-pesticide combinations were tested in duplicate to estimate the consistency, i.e. the intra-laboratory variation, in test results. Daphnia magna was tested as well to allow the test results to be compared directly with values from the literature. Results indicate that the differences between the EC50s obtained for D. magna in this study and those reported in the literature were less than a factor of 2. This indicates that the methodology used is able to provide credible toxicity values. The results of the duplicated tests showed intra-laboratory variation in EC50 values of up to a factor of 3, with one test showing a difference of a factor of 6 at 48 h. Comparison with available literature results for arthropod species using species sensitivity distributions indicated that the test results obtained in this study fit well in the log-normal distribution of the literature values. We conclude that the methodology of performing multiple tests to check for consistency of test results and performing tests with D. magna for comparison with literature values to check for accuracy is able to provide reliable effect threshold levels and that the tested Ethiopian species did not differ in sensitivity from the arthropod species reported on in the literature.
Proximal muscle weakness as a result of osteomalacia associated with celiac disease: a case report.
Oz, B; Akan, O; Kocyigit, H; Gürgan, H A
2016-02-01
A 24-year-old woman suffering from back and hip pain with difficulty in walking was reported. She had proximal muscle weakness. Laboratory findings led to the diagnosis of osteomalacia. Positivity of antibodies strengthened suspicion of celiac disease. In patients with proximal muscle weakness, osteomalacia should be considered in differential diagnosis even in a young woman. A 24-year-old woman suffering from back pain, bilateral hip pain, and difficulty in walking was reported. Her symptoms had started in the first trimester of pregnancy. In her physical examination, proximal muscle weakness and waddling gait pattern were determined. Her lumbar spine and hip MRI revealed no obvious pathological findings. Electromyography showed a myophatic pattern. Physical examination, normal values of creatine kinase, and muscle biopsy were supplied to exclude the diagnosis of primer muscle diseases. Laboratory findings led to the diagnosis of osteomalacia with normal renal function. Gastrointestinal symptoms and positivity of anti-gliadin and anti-endomysium antibodies strengthened the suspicion of celiac disease as a cause of the osteomalacia. The diagnosis of celiac disease was confirmed with duodenal mucosal biopsy. In patients with proximal muscle weakness and waddling gait pattern, osteomalacia should be considered in differential diagnosis even in a young woman and underlying disease should be investigated.
National survey on current situation of critical value reporting in 973 laboratories in China.
Fei, Yang; Zhao, Haijian; Wang, Wei; He, Falin; Zhong, Kun; Yuan, Shuai; Wang, Zhiguo
2017-10-15
The aim of the study was to investigate the state-of-the-art of the performance of critical value reporting and provide recommendations for laboratories setting critical value reporting time frames. The National Centre for Clinical Laboratories in China initiated a critical value reporting investigation in 2015. A questionnaire related to critical value reporting policy was sent to 1589 clinical laboratories in China online. The questionnaire consisted of a set of questions related to critical value reporting policy and a set of questions related to timeliness of critical value reporting. The survey data were collected between March and April 2015. A total survey response rate was 61.2%. The critical value unreported rate, unreported timely rate, and clinical unacknowledged rate of more than half of participants were all 0.0%. More than 75.0% of participants could report half of critical values to clinicians within 20 minutes and could report 90.0% of critical values to clinicians within 25 minutes (from result validation to result communication to the clinician). The median of target critical value reporting time was 15 minutes. "Reporting omission caused by laboratory staff", "communications equipment failure to connect", and "uncompleted application form without contact information of clinician" were the three major reasons for unreported critical value. The majority of laboratories can report critical values to responsible clinical staff within 25 minutes. Thus, this value could be recommended as suitable critical value reporting time frame for biochemistry laboratories in China. However, careful monitoring of the complete reporting process and improvement of information systems should ensure further improvement of critical value reporting timeliness.
Weight status and the perception of body image in men
Gardner, Rick M
2014-01-01
Understanding the role of body size in relation to the accuracy of body image perception in men is an important topic because of the implications for avoiding and treating obesity, and it may serve as a potential diagnostic criterion for eating disorders. The early research on this topic produced mixed findings. About one-half of the early studies showed that obese men overestimated their body size, with the remaining half providing accurate estimates. Later, improvements in research technology and methodology provided a clearer indication of the role of weight status in body image perception. Research in our laboratory has also produced diverse findings, including that obese subjects sometimes overestimate their body size. However, when examining our findings across several studies, obese subjects had about the same level of accuracy in estimating their body size as normal-weight subjects. Studies in our laboratory also permitted the separation of sensory and nonsensory factors in body image perception. In all but one instance, no differences were found overall between the ability of obese and normal-weight subjects to detect overall changes in body size. Importantly, however, obese subjects are better at detecting changes in their body size when the image is distorted to be too thin as compared to too wide. Both obese and normal-weight men require about a 3%–7% change in the width of their body size in order to detect the change reliably. Correlations between a range of body mass index values and body size estimation accuracy indicated no relationship between these variables. Numerous studies in other laboratories asked men to place their body size into discrete categorizes, ranging from thin to obese. Researchers found that overweight and obese men underestimate their weight status, and that men are less accurate in their categorizations than are women. Cultural influences have been found to be important, with body size underestimations occurring in cultures where a larger body is found to be desirable. Methodological issues are reviewed with recommendations for future studies. PMID:25114606
Nelson, Erik J; Wu, Jennifer Y
2017-01-17
BACKGROUND Postoperative conversion disorder is rare and has been reported. The diagnosis is usually made after all major organic causes have been ruled out. CASE REPORT We describe a case of a 13-year-old female who presented in the post-anesthesia care unit with acute-onset inspiratory stridor and unresponsiveness to verbal or painful stimuli after receiving a general anesthetic for upper endoscopy. Later in the post-anesthesia care unit, she presented with acute-onset right hemiplegia and sensory loss. She was first evaluated for causes of her stridor and unresponsiveness. The evaluation revealed paradoxical vocal cord movement, and all laboratory test values were normal. For her hemiplegia and sensory loss, she was evaluated for stroke with head MRI and CT scans, which were normal. CONCLUSIONS After extensive workup and consideration of multiple etiologies for her presenting signs and symptoms, the most likely diagnosis was conversion disorder.
Tuberculosis disease diagnosis using artificial immune recognition system.
Shamshirband, Shahaboddin; Hessam, Somayeh; Javidnia, Hossein; Amiribesheli, Mohsen; Vahdat, Shaghayegh; Petković, Dalibor; Gani, Abdullah; Kiah, Miss Laiha Mat
2014-01-01
There is a high risk of tuberculosis (TB) disease diagnosis among conventional methods. This study is aimed at diagnosing TB using hybrid machine learning approaches. Patient epicrisis reports obtained from the Pasteur Laboratory in the north of Iran were used. All 175 samples have twenty features. The features are classified based on incorporating a fuzzy logic controller and artificial immune recognition system. The features are normalized through a fuzzy rule based on a labeling system. The labeled features are categorized into normal and tuberculosis classes using the Artificial Immune Recognition Algorithm. Overall, the highest classification accuracy reached was for the 0.8 learning rate (α) values. The artificial immune recognition system (AIRS) classification approaches using fuzzy logic also yielded better diagnosis results in terms of detection accuracy compared to other empirical methods. Classification accuracy was 99.14%, sensitivity 87.00%, and specificity 86.12%.
19 CFR 351.403 - Sales used in calculating normal value; transactions between affiliated parties.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 19 Customs Duties 3 2010-04-01 2010-04-01 false Sales used in calculating normal value... ADMINISTRATION, DEPARTMENT OF COMMERCE ANTIDUMPING AND COUNTERVAILING DUTIES Calculation of Export Price, Constructed Export Price, Fair Value, and Normal Value § 351.403 Sales used in calculating normal value...
Adding value to laboratory medicine: a professional responsibility.
Beastall, Graham H
2013-01-01
Laboratory medicine is a medical specialty at the centre of healthcare. When used optimally laboratory medicine generates knowledge that can facilitate patient safety, improve patient outcomes, shorten patient journeys and lead to more cost-effective healthcare. Optimal use of laboratory medicine relies on dynamic and authoritative leadership outside as well as inside the laboratory. The first responsibility of the head of a clinical laboratory is to ensure the provision of a high quality service across a wide range of parameters culminating in laboratory accreditation against an international standard, such as ISO 15189. From that essential baseline the leadership of laboratory medicine at local, national and international level needs to 'add value' to ensure the optimal delivery, use, development and evaluation of the services provided for individuals and for groups of patients. A convenient tool to illustrate added value is use of the mnemonic 'SCIENCE'. This tool allows added value to be considered in seven domains: standardisation and harmonisation; clinical effectiveness; innovation; evidence-based practice; novel applications; cost-effectiveness; and education of others. The assessment of added value in laboratory medicine may be considered against a framework that comprises three dimensions: operational efficiency; patient management; and patient behaviours. The profession and the patient will benefit from sharing examples of adding value to laboratory medicine.
Geffré, Anne; Concordet, Didier; Braun, Jean-Pierre; Trumel, Catherine
2011-03-01
International recommendations for determination of reference intervals have been recently updated, especially for small reference sample groups, and use of the robust method and Box-Cox transformation is now recommended. Unfortunately, these methods are not included in most software programs used for data analysis by clinical laboratories. We have created a set of macroinstructions, named Reference Value Advisor, for use in Microsoft Excel to calculate reference limits applying different methods. For any series of data, Reference Value Advisor calculates reference limits (with 90% confidence intervals [CI]) using a nonparametric method when n≥40 and by parametric and robust methods from native and Box-Cox transformed values; tests normality of distributions using the Anderson-Darling test and outliers using Tukey and Dixon-Reed tests; displays the distribution of values in dot plots and histograms and constructs Q-Q plots for visual inspection of normality; and provides minimal guidelines in the form of comments based on international recommendations. The critical steps in determination of reference intervals are correct selection of as many reference individuals as possible and analysis of specimens in controlled preanalytical and analytical conditions. Computing tools cannot compensate for flaws in selection and size of the reference sample group and handling and analysis of samples. However, if those steps are performed properly, Reference Value Advisor, available as freeware at http://www.biostat.envt.fr/spip/spip.php?article63, permits rapid assessment and comparison of results calculated using different methods, including currently unavailable methods. This allows for selection of the most appropriate method, especially as the program provides the CI of limits. It should be useful in veterinary clinical pathology when only small reference sample groups are available. ©2011 American Society for Veterinary Clinical Pathology.
Zeng, Rong; Wang, Wei; Zhao, Haijian; Fei, Yang; Wang, Zhiguo
2015-01-01
The narrow gap of HbA1 value of mass fraction between "normal" (< 6.0%) and "diabetes" (≥ 6.5%) necessitates tight control of inter-assay standardization, assay precision, and trueness. This survey was initiated to obtain knowledge of the current situation of internal quality control (IQC) practice for HbA(1c) in China and find out the most appropriate quality specifications. Data of IQC for HbA(1c) in 331 institutions participating in the national proficiency testing (PT) programs in China were evaluated using four levels of quality specifications, and the percentages of laboratories meeting the quality requirement were calculated to find out the most appropriate quality specifications for control materials of HbA(1c) in China. The IQC data varied vastly among 331 clinical laboratories in China. The measurement of control materials covered a wide range from 4.52% to 12.24% (inter-quartile range) and there were significant differences among the CVs of different methods, including LPLC, CE-HPLC, AC-HPLC, immunoturbidimetry, and others. Among the four main methods, CE-HPLC and AC-HPLC achieved a better precision. As we can see, the performance of laboratories for HbA(1c) has yet to be improved. Clinical laboratories in China should improve their performance with a stricter imprecision criteria.
NASA Astrophysics Data System (ADS)
Goldfarb, E. J.; Ikeda, K.; Tisato, N.
2017-12-01
Seismic and ultrasonic velocities of rocks are function of several variables including fluid saturation and type. Understanding the effect of each variable on elastic waves can be valuable when using seismic methods for subsurface modeling. Fluid type and saturation are of specific interest to volcanology, water, and hydrocarbon exploration. Laboratory testing is often employed to understand the effects of fluids on elastic waves. However, laboratory testing is expensive and time consuming. It normally requires cutting rare samples into regular shapes. Fluid injection can also destroy specimens as removing the fluid after testing can prove difficult. Another option is theoretical modeling, which can be used to predict the effect of fluids on elastic properties, but it is often inaccurate. Alternatively, digital rock physics (DRP) can be used to investigate the effect of fluid substitution. DRP has the benefit of being non invasive, as it does not require regular sample shapes or fluid injection. Here, we compare the three methods for dry and saturated Berea sandstone to test the reliability of DRP. First, ultrasonic velocities were obtained from laboratory testing. Second, for comparison, we used a purely theoretical approach - i.e., Hashin-Shtrikman and Biot theory - to estimate the wave speeds at dry and wet conditions. Third, we used DRP. The dry sample was scanned with micro Computed Tomography (µCT), and a three dimensional (3D) array was recorded. We employed a segmentation-less method to convert each 3D array value to density, porosity, elastic moduli, and wave speeds. Wave propagation was simulated numerically at similar frequency as the laboratory. To simulate fluid substitution, we numerically substituted air values for water and repeated the simulation. The results from DRP yielded similar velocities to the laboratory, and accurately predicted the velocity change from fluid substitution. Theoretical modeling could not accurately predict velocity, and under-predicted the velocity change from fluid substitution. The mathematical approach proved to be a poor comparison for the laboratory measurement. DRP proved to be effective, and could be used in future with drill cuttings, perhaps to limit the use of expensive cores. DRP could also limit the requirement for physically testing fluid substitution.
A 3D unstructured grid nearshore hydrodynamic model based on the vortex force formalism
NASA Astrophysics Data System (ADS)
Zheng, Peng; Li, Ming; van der A, Dominic A.; van der Zanden, Joep; Wolf, Judith; Chen, Xueen; Wang, Caixia
2017-08-01
A new three-dimensional nearshore hydrodynamic model system is developed based on the unstructured-grid version of the third generation spectral wave model SWAN (Un-SWAN) coupled with the three-dimensional ocean circulation model FVCOM to enable the full representation of the wave-current interaction in the nearshore region. A new wave-current coupling scheme is developed by adopting the vortex-force (VF) scheme to represent the wave-current interaction. The GLS turbulence model is also modified to better reproduce wave-breaking enhanced turbulence, together with a roller transport model to account for the effect of surface wave roller. This new model system is validated first against a theoretical case of obliquely incident waves on a planar beach, and then applied to three test cases: a laboratory scale experiment of normal waves on a beach with a fixed breaker bar, a field experiment of oblique incident waves on a natural, sandy barred beach (Duck'94 experiment), and a laboratory study of normal-incident waves propagating around a shore-parallel breakwater. Overall, the model predictions agree well with the available measurements in these tests, illustrating the robustness and efficiency of the present model for very different spatial scales and hydrodynamic conditions. Sensitivity tests indicate the importance of roller effects and wave energy dissipation on the mean flow (undertow) profile over the depth. These tests further suggest to adopt a spatially varying value for roller effects across the beach. In addition, the parameter values in the GLS turbulence model should be spatially inhomogeneous, which leads to better prediction of the turbulent kinetic energy and an improved prediction of the undertow velocity profile.
NASA Astrophysics Data System (ADS)
Nanba, K.; Zheleznyak, M.; Konoplev, A.; Wakiyama, Y.; Golosov, V.; Wada, T.; Tsukada, H.
2015-12-01
The systematic monitoring studies of radiocesium concentrations in suspended sediments and water of the Abukuma River, the largest river of Fukushima prefecture, and its tributaries at the vicinity of Fukushima city have started in Fukushima University at the end of 2011. The scale of these field studies was extended after establishment in 2013 new Institute of Environmental Radioactivity at Fukushima University which posses the comprehensive laboratory base. The field measurements of hydrochemical water parameters and concentrations of radiocesium in water and sediments are provided in the rivers of northern coastal zone of Fukushima province with the most comprehensive program for Niida River basin. The radiocesium dynamics is studied in Sakashita Reservoir and heavily contaminated irrigation ponds of Okuma town in the vicinity of FDNPP, Takanokura Reservoir, Inawashiro Lake, Hibara Lake. Comparative analysis is provided for radiocaesium wash-off parameters and distribution coefficient in rivers and surface runoff on Fukushima and Chernobyl contaminated areas for the first years after the accidents. It is found that radiocaesium distribution coefficient in rivers of Fukushima is essentially higher (1-2 orders of magnitude) than correspondent values for rivers and surface runoff of the Chernobyl zone. Normalized dissolved wash-off coefficients for watersheds of Fukushima are at least 1 order of magnitude lower correspondent values for Chernobyl zone. Normalized particulate wash-off coefficients are comparable for Fukushima and Chernobyl. Presented are results of the investigation of radiocesium vertical distribution in soils of the close-in area of the FDNPP: Okuma town and Niida River basin. It is shown that radiocesium dispersion in undisturbed forest and grassland soils at Fukushima contaminated area is significantly faster as compared to the Chernobyl 30-km zone during the first three years after the accidents.
Deetz, Carl O; Nolan, Debra K; Scott, Mitchell G
2012-01-01
A long-standing practice in clinical laboratories has been to automatically repeat laboratory tests when values trigger automated "repeat rules" in the laboratory information system such as a critical test result. We examined 25,553 repeated laboratory values for 30 common chemistry tests from December 1, 2010, to February 28, 2011, to determine whether this practice is necessary and whether it may be possible to reduce repeat testing to improve efficiency and turnaround time for reporting critical values. An "error" was defined to occur when the difference between the initial and verified values exceeded the College of American Pathologists/Clinical Laboratory Improvement Amendments allowable error limit. The initial values from 2.6% of all repeated tests (668) were errors. Of these 668 errors, only 102 occurred for values within the analytic measurement range. Median delays in reporting critical values owing to repeated testing ranged from 5 (blood gases) to 17 (glucose) minutes.
Strength of Wet and Dry Montmorillonite
NASA Astrophysics Data System (ADS)
Morrow, C. A.; Lockner, D. A.; Moore, D. E.
2015-12-01
Montmorillonite, an expandable smectite clay, is a common mineral in fault zones to a depth of around 3 km. Its low strength relative to other common fault gouge minerals is important in many models of fault rheology. However, the coefficient of friction is not well constrained in the literature due to the difficulty of establishing fully drained or fully dried states in the laboratory. For instance, in some reported studies, samples were either partially saturated or possibly over pressured, leading to wide variability in reported shear strength. In this study, the coefficient of friction, μ, of both saturated and oven-dried (at 150°C) Na-montmorillonite was measured at normal stresses up to 680 MPa at room temperature and shortening rates from 1.0 to 0.01 μm/s. Care was taken to shear saturated samples slowly enough to avoid pore fluid overpressure in the clay layers. Coefficients of friction are reported after 8 mm of axial displacement in a triaxial apparatus on saw-cut samples containing a layer of montmorillonite gouge, with either granite or sandstone driving blocks. For saturated samples, μ increased from around 0.1 at low pressure to 0.25 at the highest test pressures. In contrast, values for oven-dried samples decreased asymptotically from approximately 0.78 at 10 MPa normal stress to around 0.45 at 400-680 MPa. While wet and dry strengths approached each other with increasing effective normal stress, wet strength remained only about half of the dry strength at 600 MPa effective normal stress. The increased coefficient of friction can be correlated with a reduction in the number of loosely bound lubricating surface water layers on the clay platelets due to applied normal stress under saturated conditions. The steady-state rate dependence of friction, a-b, was positive and dependent on normal stress. For saturated samples, a-b increased linearly with applied normal stress from ~0 to 0.004, while for dry samples a-b decreased with increasing normal stress from 0.008 to 0.002. All values were either neutral or rate strengthening, indicating a tendency for stable sliding.
web-based interactive data processing: application to stable isotope metrology.
Verkouteren, R M; Lee, J N
2001-08-01
To address a fundamental need in stable isotope metrology, the National Institute of Standards and Technology (NIST) has established a web-based interactive data-processing system accessible through a common gateway interface (CGI) program on the internet site http://www. nist.gov/widps-co2. This is the first application of a web-based tool that improves the measurement traceability afforded by a series of NIST standard materials. Specifically, this tool promotes the proper usage of isotope reference materials (RMs) and improves the quality of reported data from extensive measurement networks. Through the International Atomic Energy Agency (IAEA), we have defined standard procedures for stable isotope measurement and data-processing, and have determined and applied consistent reference values for selected NIST and IAEA isotope RMs. Measurement data of samples and RMs are entered into specified fields on the web-based form. These data are submitted through the CGI program on a NIST Web server, where appropriate calculations are performed and results returned to the client. Several international laboratories have independently verified the accuracy of the procedures and algorithm for measurements of naturally occurring carbon-13 and oxygen-18 abundances and slightly enriched compositions up to approximately 150% relative to natural abundances. To conserve the use of the NIST RMs, users may determine value assignments for a secondary standard to be used in routine analysis. Users may also wish to validate proprietary algorithms embedded in their laboratory instrumentation, or specify the values of fundamental variables that are usually fixed in reduction algorithms to see the effect on the calculations. The results returned from the web-based tool are limited in quality only by the measurements themselves, and further value may be realized through the normalization function. When combined with stringent measurement protocols, two- to threefold improvements have been realized in the reproducibility of carbon-13 and oxygen-18 determinations across laboratories.
Total ozone determination by spectroradiometry in the middle ultraviolet
NASA Technical Reports Server (NTRS)
Garrison, L. M.; Doda, D. D.; Green, A. E. S.
1979-01-01
A method has been developed to determine total ozone from multispectral measurements of the direct solar irradiance. The total ozone is determined by a least squares fit to the spectrum between 290 nm and 380 nm. The aerosol extinction is accounted for by expanding it in a power series in wavelength; use of the linear term proved adequate. A mobile laboratory incorporating a sky scanner has been developed and used to obtain data to verify the method. Sun tracking, wavelength setting of the double monochromator, and data acquisition are under control of a minicomputer. Results obtained at Wallops Island, Virginia, and Palestine, Texas, agree well with simultaneous Dobson and Canterbury spectrometer and balloon ECC ozonesonde values. The wavelength calibration of the monochromator and the values for the normalized ozone absorption are the most important factors in an accurate determination of total ozone.
New reference materials for nitrogen-isotope-ratio measurements
Böhlke, John Karl; Gwinn, C. J.; Coplen, T. B.
1993-01-01
Three new reference materials were manufactured for calibration of relative stable nitrogen-isotope-ratio measurements: USGS25 (ammonium sulfate) d15N' = -30 per mil; USGS26 (ammonium sulfate) d15N' = +54 per mil; USGS32 (potassium nitrate) d15N' = +180 per mil, where d15N', relative to atmospheric nitrogen, is an approximate value subject to change following interlaboratory comparisons. These materials are isotopically homogeneous in aliquots at least as small as 10 µmol N2 (or about 1-2 mg of salt). The new reference materials greatly extend the range of d15N values of internationally distributed standards, and they allow normalization of d15N measurements over almost the full range of known natural isotope variation on Earth. The methods used to produce these materials may be adapted to produce homogeneous local laboratory standards for routine use.
Vesty, Eleanor F; Kessler, Ralf W; Wichard, Thomas; Coates, Juliet C
2015-01-01
Green Ulvophyte macroalgae represent attractive model systems for understanding growth, development, and evolution. They are untapped resources for food, fuel, and high-value compounds, but can also form nuisance blooms. To fully analyze green seaweed morphogenesis, controlled laboratory-based culture of these organisms is required. To date, only a single Ulvophyte species, Ulva mutabilis Føyn, has been manipulated to complete its whole life cycle in laboratory culture and to grow continuously under axenic conditions. Such cultures are essential to address multiple key questions in Ulva development and in algal-bacterial interactions. Here we show that another Ulva species, U. linza, with a broad geographical distribution, has the potential to be grown in axenic culture similarly to U. mutabilis. U. linza can be reliably induced to sporulate (form gametes and zoospores) in the laboratory, by cutting the relevant thallus tissue into small pieces and removing extracellular inhibitors (sporulation and swarming inhibitors). The germ cells work as an ideal feed stock for standardized algae cultures. The requirement of U. linza for bacterial signals to induce its normal morphology (particularly of the rhizoids) appears to have a species-specific component. The axenic cultures of these two species pave the way for future comparative studies of algal-microbial interactions.
Vesty, Eleanor F.; Kessler, Ralf W.; Wichard, Thomas; Coates, Juliet C.
2015-01-01
Green Ulvophyte macroalgae represent attractive model systems for understanding growth, development, and evolution. They are untapped resources for food, fuel, and high-value compounds, but can also form nuisance blooms. To fully analyze green seaweed morphogenesis, controlled laboratory-based culture of these organisms is required. To date, only a single Ulvophyte species, Ulva mutabilis Føyn, has been manipulated to complete its whole life cycle in laboratory culture and to grow continuously under axenic conditions. Such cultures are essential to address multiple key questions in Ulva development and in algal–bacterial interactions. Here we show that another Ulva species, U. linza, with a broad geographical distribution, has the potential to be grown in axenic culture similarly to U. mutabilis. U. linza can be reliably induced to sporulate (form gametes and zoospores) in the laboratory, by cutting the relevant thallus tissue into small pieces and removing extracellular inhibitors (sporulation and swarming inhibitors). The germ cells work as an ideal feed stock for standardized algae cultures. The requirement of U. linza for bacterial signals to induce its normal morphology (particularly of the rhizoids) appears to have a species-specific component. The axenic cultures of these two species pave the way for future comparative studies of algal–microbial interactions. PMID:25674100
Critical values in hematology of 862 institutions in China.
Ye, Y Y; Zhao, H J; Fei, Y; Wang, W; He, F L; Zhong, K; Yuan, S; Wang, Z G
2017-10-01
A national survey on critical values in hematology of China laboratories was conducted to determine the current practice and assess the quality indicators so as to obtain a quality improvement. Laboratories participating were asked to submit the general information, the practice of critical value reporting, and the status of timeliness of critical value reporting. A total of 862 laboratories submitted the results. The majority of participants have included white blood cell count, blood platelet count, hemoglobin, prothrombin time, and activated partial thromboplastin time in their critical value lists. Many sources are used for establishing a critical value policy, and some of the laboratories consult with clinicians. The unreported critical value rate, late critical value reporting rate, and clinically unacknowledged rate in China are relatively low, and the median of critical value reporting time is 8-9 minutes. There exists a wide variety for critical value reporting in hematology in China. Laboratories should establish a policy of critical value reporting suited for their own situations and consult with clinicians to set critical value lists. Critical values are generally reported in a timely manner in China, but some measures should be taken to further improve the timeliness of critical value reporting. © 2017 John Wiley & Sons Ltd.
Travison, Thomas G.; Vesper, Hubert W.; Orwoll, Eric; Wu, Frederick; Kaufman, Jean Marc; Wang, Ying; Lapauw, Bruno; Fiers, Tom; Matsumoto, Alvin M.
2017-01-01
Background: Reference ranges for testosterone are essential for making a diagnosis of hypogonadism in men. Objective: To establish harmonized reference ranges for total testosterone in men that can be applied across laboratories by cross-calibrating assays to a reference method and standard. Population: The 9054 community-dwelling men in cohort studies in the United States and Europe: Framingham Heart Study; European Male Aging Study; Osteoporotic Fractures in Men Study; and Male Sibling Study of Osteoporosis. Methods: Testosterone concentrations in 100 participants in each of the four cohorts were measured using a reference method at Centers for Disease Control and Prevention (CDC). Generalized additive models and Bland-Altman analyses supported the use of normalizing equations for transformation between cohort-specific and CDC values. Normalizing equations, generated using Passing-Bablok regression, were used to generate harmonized values, which were used to derive standardized, age-specific reference ranges. Results: Harmonization procedure reduced intercohort variation between testosterone measurements in men of similar ages. In healthy nonobese men, 19 to 39 years, harmonized 2.5th, 5th, 50th, 95th, and 97.5th percentile values were 264, 303, 531, 852, and 916 ng/dL, respectively. Age-specific harmonized testosterone concentrations in nonobese men were similar across cohorts and greater than in all men. Conclusion: Harmonized normal range in a healthy nonobese population of European and American men, 19 to 39 years, is 264 to 916 ng/dL. A substantial proportion of intercohort variation in testosterone levels is due to assay differences. These data demonstrate the feasibility of generating harmonized reference ranges for testosterone that can be applied to assays, which have been calibrated to a reference method and calibrator. PMID:28324103
Untangling the Etiology of Ascites
Lopez-Molina, Michael; Shiani, Ashok V.; Oller, Kellee L.
2015-01-01
Patient: Male, 72 Final Diagnosis: Systemic amyloidosis Symptoms: — Medication: — Clinical Procedure: Liver biopsy Specialty: Gastroenterology and Hepatology Objective: Unusual clinical course Background: Amyloidosis is a systemic disease known to affect a vast range of organs, including the liver, heart, and kidney. When infiltrating the liver, amyloidosis typically does not present with cirrhosis. Typical presentation includes hepatomegaly with some mild laboratory abnormalities. Case Report: A 72-year-old man presented with a 2-week history of worsening abdominal, scrotal, and extremity swelling. He endorsed melanotic stools and intermittent dizziness with a 10-pound weight gain. Vitals revealed a blood pressure of 82/57 mmHg and a pulse of 83 beats/min with positive orthostatic changes. Mild bibasilar crackles were noted. His abdomen was moderately distended with a fluid wave present, but no hepatosplenomegaly was noted. He displayed anasarca with significant extremity and scrotal edema, but no jaundice, telangiectasias, or other stigmata of chronic liver disease were present. Liver function tests demonstrated a total bilirubin of 1.5 mg/dL (normal value: 0.2–1.2 mg/dL), AST 111 IU/L (normal value 5–34 IU/L), ALT 51 IU/L (normal value 5–55 IU/L), and GGT 583 U/L (12–64 U/L). Alkaline phosphatase was 645 U/L (40–150 U/L). Analysis of peritoneal fluid was consistent with portal hypertension due to liver disease. Given an atypical presentation of cirrhosis with unclear etiology, a biopsy was performed and revealed amyloid deposition. Conclusions: Liver disease can be due to various etiologies, many of which can present ambiguously. Although the most typical etiologies have been well defined, we present a case of an atypical presentation of hepatic amyloidosis discovered in a patient with ascites and without typical hepatomegaly. PMID:25844525
2013-01-01
In the present study, solar photocatalytic oxidation has been investigated through laboratory experiments as an alternative to conventional secondary treatment for the organic content reduction of high COD wastewater. Experiments have been performed on synthetic high COD wastewater for solar photocatalytic oxidation using a parabolic trough reactor. Parameters affecting the oxidation of organics have been investigated. The experimental design followed the sequence of dark adsorption studies of organics, followed by photolytic studies (in absence of catalyst) and finally photocatalytic studies in presence and absence of additional oxidant (H2O2). All the experimental studies have been performed at pH values of 2, 4, 6,8,10 and the initial pH value of the wastewater (normal pH). For photocatalytic studies, TiO2 has been used as a photocatalyst. Optimization of catalyst dose, pH and H2O2 concentration has been done. Maximum reduction of organic content was observed at the normal pH value of the wastewater (pH = 6.8). The reaction rate was significantly enhanced in presence of hydrogen peroxide. The optimum pH other than the Normal was in the alkaline range. Acidic pH was not found to be favourable for organic content reduction. pH was found to be a dominant factor affecting reaction rate even in presence of H2O2 as an additional oxidant. Also, the solar detoxification process was effective in treating a waste with a COD level of more than 7500 mg/L, which is a otherwise a difficult waste to treat. It can therefore be used as a treatment step in the high organic wastewater treatment during the primary stage also as it effectively reduces the COD content by 86%. PMID:23369352
The role of copeptin in patients with subarachnoid haemorrage.
Zissimopoulos, Athanassios; Vogiatzaki, Theodosia; Babatsikou, Fotini; Velissaratou, Marion; Baloka, Lukia; Karathanos, Evangelos; Pistola, Anastasia; Christofis, Xristos; Iatrou, Xristos
2015-01-01
Subarachnoid haemorrhage is responsible to a great extend for the death rate of patients who are hospitalised in intensive care units (ICU) with haemorrhage. The early detection of its severity plays an important role for the resulting health of the patients. Neurohormone Copeptin is the C-end of pro-arginine vasopressin in plasma has been used as a prognostic marker in a number of various illnesses (acute myocardial infarction, heart and renal failure, acute dyspnoea, intracerebral and subarachnoid haemorrhage, ischaemic stroke, liver cirrhosis, acute pancreatitis). However, its prognostic value in subarachnoid haemorrhage has yet to be valued. The aim of our study was to evaluate copeptin plasma values of patients with subarachnoid haemorrhage hospitalised in the ICU, as a prognostic factor for the severity of this disease. We studied 32 patients, 21 male, 11 female, (average age 59±7 years), who were hospitalised in the ICU of Univ. Hospital of Alexandroupolis. Plasma Copeptin values were measured in the Nuclear Medicine Laboratory, with the Radioimmunoassay (RIA) method. The appropriate kit, from Phoenix Pharmaceuticals Inc. (USA), was used. The x(2) student test was used for statistical analysis. The cut-off value of copeptin ranged between 0.4-4.4 pmol/L. 19 patients showed gradual increase of copeptin values, (125-578 pmol/L), with a bad prognosis of the illness (P<0.005). Four of them with extremely high copeptin values died. Decrease of copeptin values for the rest 15 patients were correlated with the improvement of their clinical condition (P<0.005). Eleven patients appeared to have high values, followed by the gradual decrease by a range of 85-12pmol/L, and had a good prognosis of the condition. Two patients with normal values demonstrated to have a good clinical condition. Patients with a gradual increase of copeptin values showed to have bad prognosis of the disease. Four with extremely high copeptin values passed away, while patients with a gradual decrease or a normal amount of copeptin values had good prognosis. It is supported that copeptin values are a reliable prognostic factor in monitoring patients with intracranial haemorrhage.
Nielsen, Jens E.; Gunner, M. R.; Bertrand García-Moreno, E.
2012-01-01
The pKa Cooperative http://www.pkacoop.org was organized to advance development of accurate and useful computational methods for structure-based calculation of pKa values and electrostatic energy in proteins. The Cooperative brings together laboratories with expertise and interest in theoretical, computational and experimental studies of protein electrostatics. To improve structure-based energy calculations it is necessary to better understand the physical character and molecular determinants of electrostatic effects. The Cooperative thus intends to foment experimental research into fundamental aspects of proteins that depend on electrostatic interactions. It will maintain a depository for experimental data useful for critical assessment of methods for structure-based electrostatics calculations. To help guide the development of computational methods the Cooperative will organize blind prediction exercises. As a first step, computational laboratories were invited to reproduce an unpublished set of experimental pKa values of acidic and basic residues introduced in the interior of staphylococcal nuclease by site-directed mutagenesis. The pKa values of these groups are unique and challenging to simulate owing to the large magnitude of their shifts relative to normal pKa values in water. Many computational methods were tested in this 1st Blind Prediction Challenge and critical assessment exercise. A workshop was organized in the Telluride Science Research Center to assess objectively the performance of many computational methods tested on this one extensive dataset. This volume of PROTEINS: Structure, Function, and Bioinformatics introduces the pKa Cooperative, presents reports submitted by participants in the blind prediction challenge, and highlights some of the problems in structure-based calculations identified during this exercise. PMID:22002877
19 CFR 351.406 - Calculation of normal value if sales are made at less than cost of production.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 19 Customs Duties 3 2010-04-01 2010-04-01 false Calculation of normal value if sales are made at less than cost of production. 351.406 Section 351.406 Customs Duties INTERNATIONAL TRADE ADMINISTRATION... Price, Fair Value, and Normal Value § 351.406 Calculation of normal value if sales are made at less than...
Estimation of value at risk and conditional value at risk using normal mixture distributions model
NASA Astrophysics Data System (ADS)
Kamaruzzaman, Zetty Ain; Isa, Zaidi
2013-04-01
Normal mixture distributions model has been successfully applied in financial time series analysis. In this paper, we estimate the return distribution, value at risk (VaR) and conditional value at risk (CVaR) for monthly and weekly rates of returns for FTSE Bursa Malaysia Kuala Lumpur Composite Index (FBMKLCI) from July 1990 until July 2010 using the two component univariate normal mixture distributions model. First, we present the application of normal mixture distributions model in empirical finance where we fit our real data. Second, we present the application of normal mixture distributions model in risk analysis where we apply the normal mixture distributions model to evaluate the value at risk (VaR) and conditional value at risk (CVaR) with model validation for both risk measures. The empirical results provide evidence that using the two components normal mixture distributions model can fit the data well and can perform better in estimating value at risk (VaR) and conditional value at risk (CVaR) where it can capture the stylized facts of non-normality and leptokurtosis in returns distribution.
Utility of repeat testing of critical values: a Q-probes analysis of 86 clinical laboratories.
Lehman, Christopher M; Howanitz, Peter J; Souers, Rhona; Karcher, Donald S
2014-06-01
A common laboratory practice is to repeat critical values before reporting the test results to the clinical care provider. This may be an unnecessary step that delays the reporting of critical test results without adding value to the accuracy of the test result. To determine the proportions of repeated chemistry and hematology critical values that differ significantly from the original value as defined by the participating laboratory, to determine the threshold differences defined by the laboratory as clinically significant, and to determine the additional time required to analyze the repeat test. Participants prospectively reviewed critical test results for 4 laboratory tests: glucose, potassium, white blood cell count, and platelet count. Participants reported the following information: initial and repeated test result; time initial and repeat results were first known to laboratory staff; critical result notification time; if the repeat result was still a critical result; if the repeat result was significantly different from the initial result, as judged by the laboratory professional or policy; significant difference threshold, as defined by the laboratory; the make and model of the instrument used for primary and repeat testing. Routine, repeat analysis of critical values is a common practice. Most laboratories did not formally define a significant difference between repeat results. Repeated results were rarely considered significantly different. Median repeated times were at least 17 to 21 minutes for 10% of laboratories. Twenty percent of laboratories reported at least 1 incident in the last calendar year of delayed result reporting that clinicians indicated had adversely affected patient care. Routine repeat analysis of automated chemistry and hematology critical values is unlikely to be clinically useful and may adversely affect patient care.
Baker, Wendy S; Albright, Kathleen J; Berman, Megan; Spratt, Heidi; Mann, Peggy A; Unabia, Jaime; Petersen, John R
2017-09-01
In this study we examined the difference in patient INR values as measured by the POCT CoaguChek XS device and central laboratory Stago Evolution and Siemens BCS XP analyzers. This study composed of 100 warfarin therapy patients and 20 coagulation normal subjects, showed that the difference between the POCT and clinical laboratory values increased with increasing INR and was exacerbated by the use of different thromboplastin reagents by the POCT and central lab. The CoaguChek XS and on-site Stago analyzers which used human recombinant (ISI=1.01) and rabbit brain thromboplastin (ISI=1.25), respectively, showed reasonable agreement for INR<3.0 (k=0.62) but significant difference for INR≥3.0 (k=0.10). In contrast, the CoaguChek XS and Siemens BCS XP, which both employed human recombinant thromboplastin (BCS ISI=1.02), showed greater agreement for the complete range INR values (INR<3.0 k=0.84; INR≥3.0 k=0.70). ECAA Poller calibrant data showed the automated instruments were performing as expected, indicating that ISI calibrations were correct but insufficient to standardize the INR values for the different thromboplastin methods across the full range of measured INRs. Central lab verification of POCT INR>5.0 with the Stago Evolution prevented adverse treatment events for the warfarin therapy patients in the six months preceding and following this investigation. Copyright © 2017 Elsevier B.V. All rights reserved.
Ruha, Anne-Michelle; Curry, Steven C; Albrecht, Clay; Riley, Brad; Pizon, Anthony
2011-01-01
North American rattlesnake envenomations commonly produce defibrination, coagulopathy and/or thrombocytopenia, which may be reversed following treatment with Crotalidae Polyvalent Immune Fab Ovine (FabAV). Despite initial resolution with FabAV, late onset or recurrence of venom-induced hematologic effects may occur. Time at which onset of late hematotoxicity may first be detected is unknown. The purpose of this study was to identify the incidence and time of onset of recurrent or new late hypofibrinogenemia, coagulopathy, or thrombocytopenia in a cohort of rattlesnake envenomation patients seen in outpatient follow-up after treatment with FabAV, and to report hematologic outcomes in these patients. Review of 66 charts of patients with rattlesnake envenomation who were treated with FabAV, and subsequently had outpatient follow-up evaluation at least 48 h after last FabAV, was performed. Demographic information, rattlesnake and bite characteristics, dose and timing of antivenom administration, adverse events, in-patient laboratory values, length of hospital stay, and follow-up laboratory values were collected. The primary outcome parameters were recurrent or delayed onset coagulopathy, hypofibrinogenemia, or thrombocytopenia identified no sooner than 48 h after last dose of FabAV. Prior to control of the envenomation with FabAV, 42 patients (63.6%) experienced hematologic toxicity. At follow-up, 21 patients (32%) were found to have late coagulopathy, hypofibrinogenemia, or thrombocytopenia. Of twenty-three patients (35%) with more than one follow-up visit, fifteen had normal laboratory findings at the first follow-up visit. Five of these 15 patients (8% of total study group; 33% of this subgroup) with normal hematologic studies at first follow-up exhibited late hematologic toxicity at second follow-up. Severe late hematologic toxicity developed in five of 66 (8%) patients. One patient was retreated with FabAV for late severe thrombocytopenia. Recurrent and delayed onset of hematologic toxicity in rattlesnake envenomation victims treated with FabAV is common. Follow-up more than three days after treatment is necessary to detect all cases of late hematologic toxicity. Copyright © 2010 Elsevier Ltd. All rights reserved.
1978-01-01
The performance of autoclaves in 27 laboratories, operated in accordance with the normal routine of local practice, has been monitored using thermometric equipment. Sterilising performance was unsatisfactory on 10 of 62 occasions, and cooling was inadequate on 52 of 60 occasions. PMID:649767
Rapid incremental methods for the determination of serum iron and iron-binding capacity
Beale, R. N.; Bostrom, J. O.; Taylor, R. F.
1961-01-01
Rapid methods depending on differential absorptiometry are described for the determination of the transferrin iron content and the latent iron-binding capacity of blood serum. Each determination requires as little as 0·5 ml. serum. The methods are well adapted for routine use in the `average' laboratory. Three or four sera may be completely analysed in 30 minutes. All operations are carried out in the cells or tubes used for the colorimetric measurements, no precipitation or heating being employed at any stage. Critical investigations of the reliability of the methods are attempted and ranges of normal values are included. PMID:13866116
Emissivity Results on High Temperature Coatings for Refractory Composite Materials
NASA Technical Reports Server (NTRS)
Ohlhorst, Craig W.; Vaughn, Wallace L.; Daryabeigi, Kamran; Lewis, Ronald K.; Rodriguez, Alvaro C.; Milhoan, James D.; Koenig, John R.
2007-01-01
The directional emissivity of various refractory composite materials considered for application for reentry and hypersonic vehicles was investigated. The directional emissivity was measured at elevated temperatures of up to 3400 F using a directional spectral radiometric technique during arc-jet test runs. A laboratory-based relative total radiance method was also used to measure total normal emissivity of some of the refractory composite materials. The data from the two techniques are compared. The paper will also compare the historical database of Reinforced Carbon-Carbon emissivity measurements with emissivity values generated recently on the material using the two techniques described in the paper.
Schimmelmann, Arndt; Qi, Haiping; Coplen, Tyler B; Brand, Willi A; Fong, Jon; Meier-Augenstein, Wolfram; Kemp, Helen F; Toman, Blaza; Ackermann, Annika; Assonov, Sergey; Aerts-Bijma, Anita T; Brejcha, Ramona; Chikaraishi, Yoshito; Darwish, Tamim; Elsner, Martin; Gehre, Matthias; Geilmann, Heike; Gröning, Manfred; Hélie, Jean-François; Herrero-Martín, Sara; Meijer, Harro A J; Sauer, Peter E; Sessions, Alex L; Werner, Roland A
2016-04-19
An international project developed, quality-tested, and determined isotope-δ values of 19 new organic reference materials (RMs) for hydrogen, carbon, and nitrogen stable isotope-ratio measurements, in addition to analyzing pre-existing RMs NBS 22 (oil), IAEA-CH-7 (polyethylene foil), and IAEA-600 (caffeine). These new RMs enable users to normalize measurements of samples to isotope-δ scales. The RMs span a range of δ(2)H(VSMOW-SLAP) values from -210.8 to +397.0 mUr or ‰, for δ(13)C(VPDB-LSVEC) from -40.81 to +0.49 mUr and for δ(15)N(Air) from -5.21 to +61.53 mUr. Many of the new RMs are amenable to gas and liquid chromatography. The RMs include triads of isotopically contrasting caffeines, C16 n-alkanes, n-C20-fatty acid methyl esters (FAMEs), glycines, and l-valines, together with polyethylene powder and string, one n-C17-FAME, a vacuum oil (NBS 22a) to replace NBS 22 oil, and a (2)H-enriched vacuum oil. A total of 11 laboratories from 7 countries used multiple analytical approaches and instrumentation for 2-point isotopic normalization against international primary measurement standards. The use of reference waters in silver tubes allowed direct normalization of δ(2)H values of organic materials against isotopic reference waters following the principle of identical treatment. Bayesian statistical analysis yielded the mean values reported here. New RMs are numbered from USGS61 through USGS78, in addition to NBS 22a. Because of exchangeable hydrogen, amino acid RMs currently are recommended only for carbon- and nitrogen-isotope measurements. Some amino acids contain (13)C and carbon-bound organic (2)H-enrichments at different molecular sites to provide RMs for potential site-specific isotopic analysis in future studies.
Schimmelmann, Arndt; Qi, Haiping; Coplen, Tyler B.; Brand, Willi A.; Fong, Jon; Meier-Augenstein, Wolfram; Kemp, Helen F.; Toman, Blaza; Ackermann, Annika; Assonov, Sergey; Aerts-Bijma, Anita; Brejcha, Ramona; Chikaraishi, Yoshito; Darwish, Tamim; Elsner, Martin; Gehre, Matthias; Geilmann, Heike; Gröning, Manfred; Hélie, Jean-François; Herrero-Martín, Sara; Meijer, Harro A.J.; Sauer, Peter E.; Sessions, Alex L.; Werner, Roland A.
2016-01-01
An international project developed, quality-tested, and determined isotope−δ values of 19 new organic reference materials (RMs) for hydrogen, carbon, and nitrogen stable isotope-ratio measurements, in addition to analyzing pre-existing RMs NBS 22 (oil), IAEA-CH-7 (polyethylene foil), and IAEA-600 (caffeine). These new RMs enable users to normalize measurements of samples to isotope−δ scales. The RMs span a range of δ2HVSMOW-SLAP values from −210.8 to +397.0 mUr or ‰, for δ13CVPDB-LSVEC from −40.81 to +0.49 mUr and for δ15NAir from −5.21 to +61.53 mUr. Many of the new RMs are amenable to gas and liquid chromatography. The RMs include triads of isotopically contrasting caffeines, C16 n-alkanes, n-C20-fatty acid methyl esters (FAMEs), glycines, and l-valines, together with polyethylene powder and string, one n-C17-FAME, a vacuum oil (NBS 22a) to replace NBS 22 oil, and a 2H-enriched vacuum oil. A total of 11 laboratories from 7 countries used multiple analytical approaches and instrumentation for 2-point isotopic normalization against international primary measurement standards. The use of reference waters in silver tubes allowed direct normalization of δ2H values of organic materials against isotopic reference waters following the principle of identical treatment. Bayesian statistical analysis yielded the mean values reported here. New RMs are numbered from USGS61 through USGS78, in addition to NBS 22a. Because of exchangeable hydrogen, amino acid RMs currently are recommended only for carbon- and nitrogen-isotope measurements. Some amino acids contain 13C and carbon-bound organic 2H-enrichments at different molecular sites to provide RMs for potential site-specific isotopic analysis in future studies.
2013-01-01
Background Previous studies have reported the lower reference limit (LRL) of quantitative cord glucose-6-phosphate dehydrogenase (G6PD), but they have not used approved international statistical methodology. Using common standards is expecting to yield more true findings. Therefore, we aimed to estimate LRL of quantitative G6PD detection in healthy term neonates by using statistical analyses endorsed by the International Federation of Clinical Chemistry (IFCC) and the Clinical and Laboratory Standards Institute (CLSI) for reference interval estimation. Methods This cross sectional retrospective study was performed at King Abdulaziz Hospital, Saudi Arabia, between March 2010 and June 2012. The study monitored consecutive neonates born to mothers from one Arab Muslim tribe that was assumed to have a low prevalence of G6PD-deficiency. Neonates that satisfied the following criteria were included: full-term birth (37 weeks); no admission to the special care nursery; no phototherapy treatment; negative direct antiglobulin test; and fathers of female neonates were from the same mothers’ tribe. The G6PD activity (Units/gram Hemoglobin) was measured spectrophotometrically by an automated kit. This study used statistical analyses endorsed by IFCC and CLSI for reference interval estimation. The 2.5th percentiles and the corresponding 95% confidence intervals (CI) were estimated as LRLs, both in presence and absence of outliers. Results 207 males and 188 females term neonates who had cord blood quantitative G6PD testing met the inclusion criteria. Method of Horn detected 20 G6PD values as outliers (8 males and 12 females). Distributions of quantitative cord G6PD values exhibited a normal distribution in absence of the outliers only. The Harris-Boyd method and proportion criteria revealed that combined gender LRLs were reliable. The combined bootstrap LRL in presence of the outliers was 10.0 (95% CI: 7.5-10.7) and the combined parametric LRL in absence of the outliers was 11.0 (95% CI: 10.5-11.3). Conclusion These results contribute to the LRL of quantitative cord G6PD detection in full-term neonates. They are transferable to another laboratory when pre-analytical factors and testing methods are comparable and the IFCC-CLSI requirements of transference are satisfied. We are suggesting using estimated LRL in absence of the outliers as mislabeling G6PD-deficient neonates as normal is intolerable whereas mislabeling G6PD-normal neonates as deficient is tolerable. PMID:24016342
Sussadee, Metita; Phavaphutanon, Janjira; Kornkaewrat, Kornchai
2015-01-01
The purpose of the present study was to establish normal electroretinogram (ERG) parameters using 56 normal eyes of four dog breeds common in Thailand: poodle, Labrador retriever, Thai ridgeback, and Thai Bangkaew. Standard ERG findings were bilaterally recorded using a handheld multi-species ERG unit with an ERG-jet lens electrode for 28 dogs under preanesthesia with diazepam, anesthesia with propofol, and anesthesia maintenance with isoflurane. There were significant differences in the mean values of ERG amplitudes and implicit times among the four dog breeds (p < 0.05) except for the b-wave implicit time of the photopic 30 Hz flicker response with 3 cd.s/m2 (p = 0.610). Out of the four breeds, Thai Bangkaew had the longest implicit time (p < 0.001) of scotopic low intensity responses, b-wave of scotopic standard intensity responses (3 cd.s/m2), a-wave of the higher intensity response (10 cd.s/m2), and a-wave of the photopic single flash response (3 cd.s/m2). For the b/a ratio, only the ratio of the Cone response was significantly different among the different breeds. In this summary, normal ERG parameters for four dog breeds were reported. Data from the investigation supported the hypothesis that determination of breed-specific limits of normality for ERG responses is necessary for individual clinics and laboratories. PMID:25269713
Delta 14CO2 Record from Vermunt, Austria, February 1959 - June 1983
Levin, Ingeborg [Institut fur Umweltphysik, University of Heidelberg, Germany; Kromer, Bernd [Institut fur Umweltphysik, University of Heidelberg, Germany; Schoch-Fischer, H. [Institut fur Umweltphysik, University of Heidelberg, Germany; Bruns, M. [Institut fur Umweltphysik, University of Heidelberg, Germany; Munnich, M. [Institut fur Umweltphysik, University of Heidelberg, Germany; Berdau, D. [Institut fur Umweltphysik, University of Heidelberg, Germany; Vogel, J. C. [Institut fur Umweltphysik, University of Heidelberg, Germany; Munnich, K. O. [Institut fur Umweltphysik, University of Heidelberg, Germany
1994-01-01
The sampling at Vermunt was discontinued in 1983. During sampling from 1959 to 1983, the sampling methods were modified twice (Levin et al. 1985). From 1959 through November 1965, three dishes with 1.5 L of 0.5 normal sodium hydroxide (NaOH) carbonate-free solution were exposed to the atmosphere for ~3 days, and the atmospheric CO2 absorbed during that time was recovered by acid evolution. From November 1965 through May 1975, samples were collected by pumping fresh air continuously for 10 days through a box containing 1.5 L of a 0.5 normal NaOH solution. The method has been described by Münnich and Vogel (1959). From May 1975 to the time sampling stopped, a technique described by Levin et al. (1980) was used. Air was pumped through a rotating glass tube filled with a packed bed of Raschig rings (hard glass) to enlarge the surface of the absorbing NaOH solution (200 ml of 4 normal NaOH). The CO2 absorption was quantitative and samples represent mean values of 10 days to 2 weeks. In the laboratory, the samples were extracted from the NaOH solution in a vacuum system by adding hydrochloric or sulfuric acid. The CO2 gas samples were purified over charcoal and counted in a proportional counter (Schoch et al. 1980). Delta 14C values are given relative to the NIST oxalic acid activity corrected for decay (Stuiver and Polach 1970).
Coronary flow reserve in patients with diabetes mellitus and prediabetes.
Atar, Asli I; Altuner, Tugba Kayhan; Bozbas, Huseyin; Korkmaz, Mehmet E
2012-07-01
Abnormalities of coronary microcirculation have been reported in patients with diabetes mellitus (DM) even in the presence of normal coronary arteries. It is unknown when the microvascular effects on coronary arteries begin to appear in the DM disease course. Coronary flow reserve (CFR), determined by pharmacological stress transthoracic Doppler echocardiography, is a reliable indicator of coronary microvascular function. We sought to determine the coronary microvascular function of prediabetic patients compared to DM patients and normal population. Seventy-four subjects with normal coronary arteries were enrolled. DM and prediabetes were diagnosed according to American Diabetes Association criteria. All subjects had Doppler recordings of the left anterior descending artery with adenosine infusion at a rate of 0.014 mg/kg per minute. The demographical characteristics and laboratory findings of the three groups were similar (DM group: n = 25, mean age 62 ± 7 years, 19 females; prediabetic group: n = 25, mean age 64 ± 12 years, 21 females; control group: n = 24, mean age 63 ± 7 years, 15 females) except fasting glucose levels. CFR values of the three groups were significantly different (DM group: CFR = 1.75 ± 0.50; prediabetic group: CFR = 2.24 ± 0.43; control group: CFR = 2.38 ± 0.32, P < 0.001). CFR values of DM group were lower than those of prediabetic and control groups (DM vs. prediabetic: P < 0.001, DM vs. control: P < 0.001). However, CFR levels of prediabetic group were not different from those of the control group (P = 0.481). DM was an independent factor predictive of CFR < 2 (OR, 22.69; 95% CI, 6.47-79.51; P < 0.001). Coronary microvascular function seems to be normal in the prediabetic state, but dysfunction appears after DM becomes overt. © 2012, Wiley Periodicals, Inc.
Intraoral Laser Welding (ILW): ultrastructural and mechanical analysis
NASA Astrophysics Data System (ADS)
Fornaini, Carlo; Passaretti, Francesca; Villa, Elena; Nammour, Samir
2010-05-01
Nd:YAG, currently used since 1970 in dental laboratories to weld metals on dental prostheses has some limits such great dimensions, high costs and fixed delivery system. Recently it was proposed the possibility to use the Nd:YAG laser device commonly utilised in dental office, to repair broken fixed, removable and orthodontic prostheses and to weld metals directly into the mouth. The aim of this work is to value, through SEM (Scanning Electron Microscope), EDS (Energy Dispersive X-Ray Spectroscopy) and DMA (Dynamic Mechanical Analysis), quality and mechanical strength of the welding process comparing a device normally used in dental lab and a device normally used in dental office for oral surgery. Sixteen CoCrMo metal plates and twenty steel orthodontic wires were divided in four groups: one was welded without metal apposition by laboratory laser, one was welded with metal apposition by laboratory laser, one was welded without metal apposition by office laser and one was welded with metal apposition by office laser. The welding process was analysed by SEM, EDS and DMA to compare the differences between the different samples. By SEM analysis it was seen that the plates welded by office laser without apposition metal showed a greater number of fissurations compared with the other samples. By EDS analysis it was seen a homogeneous composition of the metals in all the samples. The mechanical tests showed a similar elastic behaviour of the samples, with minimal differences between the two devices. No wire broke even under the maximum strength by the Analyser. This study seems to demonstrate that the welding process by office Nd:YAG laser device and the welding process by laboratory Nd:YAG laser device, analysed by SEM, EDS and DMA, showed minimal and not significant differences even if these data will be confirmed by a greater number of samples.
Makretsov, Nikita; Gilks, C Blake; Alaghehbandan, Reza; Garratt, John; Quenneville, Louise; Mercer, Joel; Palavdzic, Dragana; Torlakovic, Emina E
2011-07-01
External quality assurance and proficiency testing programs for breast cancer predictive biomarkers are based largely on traditional ad hoc design; at present there is no universal consensus on definition of a standard reference value for samples used in external quality assurance programs. To explore reference values for estrogen receptor and progesterone receptor immunohistochemistry in order to develop an evidence-based analytic platform for external quality assurance. There were 31 participating laboratories, 4 of which were previously designated as "expert" laboratories. Each participant tested a tissue microarray slide with 44 breast carcinomas for estrogen receptor and progesterone receptor and submitted it to the Canadian Immunohistochemistry Quality Control Program for analysis. Nuclear staining in 1% or more of the tumor cells was a positive score. Five methods for determining reference values were compared. All reference values showed 100% agreement for estrogen receptor and progesterone receptor scores, when indeterminate results were excluded. Individual laboratory performance (agreement rates, test sensitivity, test specificity, positive predictive value, negative predictive value, and κ value) was very similar for all reference values. Identification of suboptimal performance by all methods was identical for 30 of 31 laboratories. Estrogen receptor assessment of 1 laboratory was discordant: agreement was less than 90% for 3 of 5 reference values and greater than 90% with the use of 2 other reference values. Various reference values provide equivalent laboratory rating. In addition to descriptive feedback, our approach allows calculation of technical test sensitivity and specificity, positive and negative predictive values, agreement rates, and κ values to guide corrective actions.
Aguirre, J Ignacio; Edmonds, Kent; Zamora, Bernadette; Pingel, Jennifer; Thomas, Linda; Cancel, Denisse; Schneider, Laura; Reinhard, Mary K; Battles, August H; Akhter, Mohammed P; Kimmel, Donald B; Wronski, Thomas J
2015-01-01
Rice rats (Oryzomys palustris) are a recognized animal model for studying periodontal disease and the photoperiodic regulation of reproduction. Here we share information regarding the breeding, husbandry, veterinary care, and hematologic findings about this animal species to facilitate its use in studies at other research institutions. Rice rats initially were quarantined and monitored for excluded pathogens by using microbiologic, parasitologic, and serologic methods with adult female Mus musculus and Rattus norvegicus sentinel animals. Breeders were paired in a monogamous, continuous-breeding system. Rats were housed in static filter-top cages, maintained on commercial chow under 14:10-h light:dark cycles at 68 to 79 °F (20.0 to 26.1 °C) and 30% to 70% humidity. Rice rats apparently adapt relatively well to standard laboratory conditions, despite their aggressive behavior toward conspecifics and humans. Our analysis of 97 litters revealed that dams gave birth to an average of 5.2 pups per dam and weaned 4.2 pups per dam. Several procedures and biologic reagents normally used in standard laboratory rodents (mice and rats) can be used with rice rats. In addition, we present hematologic and serum chemistry values that can be used as preliminary reference values for future studies involving rice rats.
Aguirre, J Ignacio; Edmonds, Kent; Zamora, Bernadette; Pingel, Jennifer; Thomas, Linda; Cancel, Denisse; Schneider, Laura; Reinhard, Mary K; Battles, August H; Akhter, Mohammed P; Kimmel, Donald B; Wronski, Thomas J
2015-01-01
Rice rats (Oryzomys palustris) are a recognized animal model for studying periodontal disease and the photoperiodic regulation of reproduction. Here we share information regarding the breeding, husbandry, veterinary care, and hematologic findings about this animal species to facilitate its use in studies at other research institutions. Rice rats initially were quarantined and monitored for excluded pathogens by using microbiologic, parasitologic, and serologic methods with adult female Mus musculus and Rattus norvegicus sentinel animals. Breeders were paired in a monogamous, continuous-breeding system. Rats were housed in static filter-top cages, maintained on commercial chow under 14:10-h light:dark cycles at 68 to 79 °F (20.0 to 26.1 °C) and 30% to 70% humidity. Rice rats apparently adapt relatively well to standard laboratory conditions, despite their aggressive behavior toward conspecifics and humans. Our analysis of 97 litters revealed that dams gave birth to an average of 5.2 pups per dam and weaned 4.2 pups per dam. Several procedures and biologic reagents normally used in standard laboratory rodents (mice and rats) can be used with rice rats. In addition, we present hematologic and serum chemistry values that can be used as preliminary reference values for future studies involving rice rats. PMID:25651091
Autoantibodies and their Judicious Use in Pediatric Rheumatology Practice.
Saikia, Biman; Rawat, Amit; Vignesh, Pandiarajan
2016-01-01
Autoantibody testing forms an important part of diagnostic workup of patients in Pediatric rheumatology practice. However it is important to understand that the mere presence of autoantibodies does not necessarily mean the presence of an underlying autoimmune disease. Autoantibodies may be present decades before the development of clinical manifestations of an autoimmune disease and may be viewed as harbingers of Autoimmune disease. On the other hand, low-affinity autoantibodies may be present in normal healthy individuals; these natural autoantibodies serve an important function in immune regulation and tolerance. Autoantibody testing in pediatric practice mainly includes testing for anti-nuclear antibodies, anti-dsDNA antibodies, anti-neutrophil cytoplasmic autoantibodies and antiphospholipid antibodies. Rheumatoid factor and anti-CCP do not have much significance in the diagnostic schema in pediatric rheumatology, except perhaps for classification of juvenile idiopathic arthritis (JIA) and prognostication in late-onset polyarticular JIA. The positive predictive value (PPV) of any laboratory test depends on the prevalence of the disease in the population being tested. Hence, test ordering practices greatly impact the performance characteristics and positive predictive value of any laboratory test. A restricted test ordering only in patients with clinical signs and symptoms suggestive of autoimmune disease would thus greatly increase the PPV of tests such as antinuclear antibody used for diagnosing autoimmunity.
Zuliani, Tea; Milačič, Radmila; Ščančar, Janez
2012-05-01
The characterisation of a laboratory quality control material (QCM) for dibutyltin (DBT) and tributyltin (TBT) in sewage sludge is described. The reference values were determined by the use of two different types of isotope-dilution mass spectrometry: gas chromatography-mass spectrometry and gas chromatography-inductively coupled plasma mass spectrometry. To avoid possible analytical errors such as non-quantitative extraction and species degradation during sample preparation, different extraction methods were tested (microwave- and ultrasound-assisted extraction and mechanical stirring). The reference values were based on the unweighted means of results from the homogenisation and characterisation studies. The reference values obtained were 1,553 ± 87 and 534 ± 38 ng Sn g(-1) for DBT and TBT, respectively. In the uncertainty budget estimation, the sample inhomogeneity and between-method imprecision were taken into account. The concentrations of DBT and TBT in QCM are similar to those in the harbour sediment certified reference material PACS-2. Likewise, the levels of DBT and TBT are in the range of these compounds normally present in sewage sludge worldwide. In the future, the QCM will be used for an intercomparison study on DBT and TBT in sewage sludge, and as a day-to-day QCM during studies concerning the application of sewage sludge as an additive to artificial soil or as a raw material in civil engineering construction.
Characteristics from Recycled of Zinc Anode used as a Corrosion Preventing Material on Board Ship
NASA Astrophysics Data System (ADS)
Barokah, B.; Semin, S.; Kaligis, D. D.; Huwae, J.; Fanani, M. Z.; Rompas, P. T. D.
2018-02-01
The objective of this research is to obtain the values of chemical composition, electrochemical potential and electrochemical efficiency. Methods used were experiment with physical tests conducted in metallurgical laboratory and DNV-RP-B401 cathode protection design DNV (Det Norske Veritas) standard. The results showed that the composition of chemical as Zinc (Zn), Aluminium, Cadmium, Plumbumb, Copper and Indium is suitable of standard. The values of electrochemical potential and electrochemical efficiency were respectively. However it can be concluded that the normal meaning of recycled zinc anode with increasing melting temperature can produce zinc anode better than original zinc anode and can be used as cathode protection on board ships. This research can assist in the management of used zinc anode waste, the supply of zinc anodes for consumers at relatively low prices, and recommendations of using zinc anodes for the prevention of corrosion on board ship.
DOE Office of Scientific and Technical Information (OSTI.GOV)
McKenzie-Carter, M.A.; Lyon, R.E.
This report contains information to support the Environmental Assessment for the Compact Ignition Tokamak Project (CIT) proposed for Princeton Plasma Physics Laboratory (PPPL). The assumptions and methodology used to assess the impact to members of the public from operational and accidental releases of radioactive material from the proposed CIT during the operational period of the project are described. A description of the tracer release tests conducted at PPPL by NOAA is included; dispersion values from these tests are used in the dose calculation. Radiological releases, doses, and resulting health risks are calculated. The computer code AIRDOS-EPA is used to calculatemore » the individual and population doses for routine releases; FUSCRAC3 is used to calculate doses resulting from off-normal releases where direct application of the NOAA tracer test data is not practical. Where applicable, doses are compared to regulatory limits and guidelines values. 44 refs., 5 figs., 18 tabs.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
McKenzie-Carter, M.A.; Lyon, R.E.; Rope, S.K.
This report contains information to support the Environmental Assessment for the Burning Plasma Experiment (BPX) Project proposed for the Princeton Plasma Physics Laboratory (PPPL). The assumptions and methodology used to assess the impact to members of the public from operational and accidental releases of radioactive material from the proposed BPX during the operational period of the project are described. A description of the tracer release tests conducted at PPPL by NOAA is included; dispersion values from these tests are used in the dose calculations. Radiological releases, doses, and resulting health risks are calculated and summarized. The computer code AIRDOS- EPA,more » which is part of the computer code system CAP-88, is used to calculate the individual and population doses for routine releases; FUSCRAC3 is used to calculate doses resulting from off-normal releases where direct application of the NOAA tracer test data is not practical. Where applicable, doses are compared to regulatory limits and guideline values. 48 refs., 16 tabs.« less
Borges, E; Setti, A S; Braga, D P A F; Figueira, R C S; Iaconelli, A
2016-09-01
The objective of this study was to compare (i) the intracytoplasmic sperm injection outcomes among groups with different total motile sperm count ranges, (ii) the intracytoplasmic sperm injection outcomes between groups with normal and abnormal total motile sperm count, and (iii) the predictive values of WHO 2010 cut-off values and pre-wash total motile sperm count for the intracytoplasmic sperm injection outcomes, in couples with male infertility. This study included data from 518 patients undergoing their first intracytoplasmic sperm injection cycle as a result of male infertility. Couples were divided into five groups according to their total motile sperm count: Group I, total motile sperm count <1 × 10(6) ; group II, total motile sperm count 1-5 × 10(6) ; group III, total motile sperm count 5-10 × 10(6) ; group IV, total motile sperm count 10-20 × 10(6) ; and group V, total motile sperm count >20 × 10(6) (which was considered a normal total motile sperm count value). Then, couples were grouped into an abnormal and normal total motile sperm count group. The groups were compared regarding intracytoplasmic sperm injection outcomes. The predictive values of WHO 2010 cut-off values and total motile sperm count for the intracytoplasmic sperm injection outcomes were also investigated. The fertilization rate was lower in total motile sperm count group I compared to total motile sperm count group V (72.5 ± 17.6 vs. 84.9 ± 14.4, p = 0.011). The normal total motile sperm count group had a higher fertilization rate (84.9 ± 14.4 vs. 81.1 ± 15.8, p = 0.016) and lower miscarriage rate (17.9% vs. 29.5%, p = 0.041) compared to the abnormal total motile sperm count group. The total motile sperm count was the only parameter that demonstrated a predictive value for the formation of high-quality embryos on D2 (OR: 1.18, p = 0.013), formation of high-quality embryos on D3 (OR: 1.12, p = 0.037), formation of blastocysts on D5 (OR: 1.16, p = 0.011), blastocyst expansion grade on D5 (OR: 1.27, p = 0.042), and the odds of miscarriage (OR: 0.52, p < 0.045). The total motile sperm count has a greater predictive value than the WHO 2010 cut-off values for laboratory results and pregnancy outcomes in couples undergoing intracytoplasmic sperm injection as a result of male infertility. © 2016 American Society of Andrology and European Academy of Andrology.
Srivastava, Abneesh; Michael Verkouteren, R
2018-07-01
Isotope ratio measurements have been conducted on a series of isotopically distinct pure CO 2 gas samples using the technique of dual-inlet isotope ratio mass spectrometry (DI-IRMS). The influence of instrumental parameters, data normalization schemes on the metrological traceability and uncertainty of the sample isotope composition have been characterized. Traceability to the Vienna PeeDee Belemnite(VPDB)-CO 2 scale was realized using the pure CO 2 isotope reference materials(IRMs) 8562, 8563, and 8564. The uncertainty analyses include contributions associated with the values of iRMs and the repeatability and reproducibility of our measurements. Our DI-IRMS measurement system is demonstrated to have high long-term stability, approaching a precision of 0.001 parts-per-thousand for the 45/44 and 46/44 ion signal ratios. The single- and two-point normalization bias for the iRMs were found to be within their published standard uncertainty values. The values of 13 C/ 12 C and 18 O/ 16 O isotope ratios are expressed relative to VPDB-CO 2 using the [Formula: see text] and [Formula: see text] notation, respectively, in parts-per-thousand (‰ or per mil). For the samples, value assignments between (-25 to +2) ‰ and (-33 to -1) ‰ with nominal combined standard uncertainties of (0.05, 0.3) ‰ for [Formula: see text] and [Formula: see text], respectively were obtained. These samples are used as laboratory reference to provide anchor points for value assignment of isotope ratios (with VPDB traceability) to pure CO 2 samples. Additionally, they serve as potential parent isotopic source material required for the development of gravimetric based iRMs of CO 2 in CO 2 -free dry air in high pressure gas cylinder packages at desired abundance levels and isotopic composition values. Graphical abstract CO 2 gas isotope ratio metrology.
Space radiation studies for the reporting period, June 1983 - July 1984
NASA Technical Reports Server (NTRS)
1985-01-01
Two Active Radiation Dosimeters (ARD's) flown on Spacelab 1, performed without fault and were returned to Space Science Laboratory, MSFC for recalibration. During the flight in December 1983, performance was monitored at the Huntsville Operations Center (HOSC). Despite some problems with the Shuttle data system handling the VFI, it could be established that the ARD's were operating normally. Postflight calibrations of both units determined that sensitivities were essentially unchanged from preflight values. Flight tapes were received for approximately 60% of the flight and it appears that this is the total available. The next phase of effort will involve close collaboration with Space Science Laboratory, MSFC, in the analysis of this data. The Nuclear Radiation Monitor (NRM) was under assembly and testing at MSFC. Support was rendered in the areas of materials control and parts were supplied for the supplementary heaters, dome gas-venting device and photomultiplier tube housing. Performance characteristics of some flight-space photomultipliers were measured.
Holden, Brad; Guice, Erica A
2014-05-01
In clinical and forensic toxicology laboratories, one commonly used method for urine specimen validity testing is creatinine concentration. In this study, workplace guidelines are examined to determine their relevance to forensic and clinical toxicology samples. Specifically, it investigates the occurrence of urine creatinine concentrations under 20 mg/dL and notes potential issues with factors influencing creatinine concentration by utilizing a simple, novel method consisting of cation-paring high-pressure liquid chromatography in tandem with ultraviolet detection to determine the creatinine concentration in 3019 donors. Of the 4227 sample population in this study, 209 (4.94%) were below the cutoff value of 20 mg/dL for dilute urine. Because there are many factors that can influence the urinary creatinine concentration, samples that have creatinine under the 20 mg/dL cutoff do not always implicate sample adulteration. © 2014 American Academy of Forensic Sciences.
Using iRT, a normalized retention time for more targeted measurement of peptides
Escher, Claudia; Reiter, Lukas; MacLean, Brendan; Ossola, Reto; Herzog, Franz; Chilton, John; MacCoss, Michael J.; Rinner, Oliver
2014-01-01
Multiple reaction monitoring (MRM) has recently become the method of choice for targeted quantitative measurement of proteins using mass spectrometry. The method, however, is limited in the number of peptides that can be measured in one run. This number can be markedly increased by scheduling the acquisition if the accurate retention time (RT) of each peptide is known. Here we present iRT, an empirically derived dimensionless peptide-specific value that allows for highly accurate RT prediction. The iRT of a peptide is a fixed number relative to a standard set of reference iRT-peptides that can be transferred across laboratories and chromatographic systems. We show that iRT facilitates the setup of multiplexed experiments with acquisition windows more than 4 times smaller compared to in silico RT predictions resulting in improved quantification accuracy. iRTs can be determined by any laboratory and shared transparently. The iRT concept has been implemented in Skyline, the most widely used software for MRM experiments. PMID:22577012
NASA Technical Reports Server (NTRS)
1989-01-01
Two Active Radiation Dosimeters (ARD's) flown on Spacelab 1, performed without fault and were returned to Space Science Laboratory, MSFC for recalibration. During the flight, performance was monitored at the Huntsville Operations Center (HOSC). Despite some problems with the Shuttle data system handling the verification flight instrumentation (VFI), it was established that the ARD's were operating normally. Postflight calibrations of both units determined that sensitivities were essentially unchanged from preflight values. Flight tapes were received for approx. 60 percent of the flight and it appears that this is the total available. The data was analyzed in collaboration with Space Science Laboratory, MSFC. Also, the Nuclear Radiation Monitor (NRM) was assembled and tested at MSFC. Support was rendered in the areas of materials control and parts were supplied for the supplementary heaters, dome gas-venting device and photomultiplier tube housing. Performance characteristics of some flight-space photomultipliers were measured. The NRM was flown on a balloon-borne test flight and subsequently performed without fault on Spacelab-2. This data was analyzed and published.
Le, Margaret; Flores, David; May, Danica; Gourley, Eric; Nangia, Ajay K
2016-05-01
The evaluation and management of male hypogonadism should be based on symptoms and on serum testosterone levels. Diagnostically this relies on accurate testing and reference values. Our objective was to define the distribution of reference values and assays for free and total testosterone by clinical laboratories in the United States. Upper and lower reference values, assay methodology and source of published reference ranges were obtained from laboratories across the country. A standardized survey was reviewed with laboratory staff via telephone. Descriptive statistics were used to tabulate results. We surveyed a total of 120 laboratories in 47 states. Total testosterone was measured in house at 73% of laboratories. At the remaining laboratories studies were sent to larger centralized reference facilities. The mean ± SD lower reference value of total testosterone was 231 ± 46 ng/dl (range 160 to 300) and the mean upper limit was 850 ± 141 ng/dl (range 726 to 1,130). Only 9% of laboratories where in-house total testosterone testing was performed created a reference range unique to their region. Others validated the instrument recommended reference values in a small number of internal test samples. For free testosterone 82% of laboratories sent testing to larger centralized reference laboratories where equilibrium dialysis and/or liquid chromatography with mass spectrometry was done. The remaining laboratories used published algorithms to calculate serum free testosterone. Reference ranges for testosterone assays vary significantly among laboratories. The ranges are predominantly defined by limited population studies of men with unknown medical and reproductive histories. These poorly defined and variable reference values, especially the lower limit, affect how clinicians determine treatment. Copyright © 2016 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
Laboratory ginning and blending impacts on cotton fiber micronaire measurements
USDA-ARS?s Scientific Manuscript database
Micronaire, a critical cotton quality parameter, is normally measured in a conditioned laboratory, but increasing interest has been shown in new technologies that can measure micronaire both in and outside of the laboratory. Near Infrared (NIR) technology has demonstrated its ability to measure cot...
Baid, Smita K; Sinaii, Ninet; Wade, Matt; Rubino, Domenica; Nieman, Lynnette K
2007-08-01
Although bedtime salivary cortisol measurement has been proposed as the optimal screening test for the diagnosis of Cushing's syndrome, its performance using commercially available assays has not been widely evaluated. Our objective was to compare RIA and tandem mass spectrometry (LC-MS/MS) measurement of salivary cortisol in obese subjects and healthy volunteers. We conducted a cross-sectional prospective study of outpatients. We studied 261 obese subjects (186 female) with at least two additional features of Cushing's syndrome and 60 healthy volunteers (30 female). Subjects provided split bedtime salivary samples for cortisol measurement by commercially available RIA and LC-MS/MS. Results were considered normal or abnormal based on the laboratory reference range. Subjects with abnormal results underwent evaluation for Cushing's syndrome. In paired samples, RIA gave a lower specificity than LC-MS/MS in obese subjects (86 vs. 94%, P = 0.008) but not healthy volunteers (86 vs. 82%, P = 0.71). Among subjects with at least one abnormal result, both values were abnormal in 44% (confidence interval 26-62%) of obese and 75% (confidence interval 33-96%) of healthy volunteers. In obese subjects, salivary cortisol concentrations were less than 4.0 to 643 ng/dl (<0.11-17.7 nmol/liter; normal, < or =100 ng/dl, 2.80 nmol/liter) by LC-MS/MS and less than 50 to 2800 ng/dl (1.4-77.3 nmol/liter; normal, < or =170 ng/dl, 4.7 nmol/liter) by RIA. Cushing's syndrome was not diagnosed in any subject. Salivary cortisol levels should not be used as the sole test to diagnose Cushing's syndrome if laboratory-provided reference ranges are used for diagnostic interpretation.
A systematic investigation into b values prior to coming large earthquakes
NASA Astrophysics Data System (ADS)
Nanjo, K.; Yoshida, A.
2017-12-01
The Gutenberg-Richter law for frequency-magnitude distribution of earthquakes is now well established in seismology. The b value, the slope of the distribution, is supposed to reflect heterogeneity of seismogenic region (e.g. Mogi 1962) and development of interplate coupling in subduction zone (e.g. Nanjo et al., 2012; Tormann et al. 2015). In the laboratory as well as in the Earth's crust, the b value is known to be inversely dependent on differential stresses (Scholz 1968, 2015). In this context, the b value could serve as a stress meter to help locate asperities, the highly-stressed patches, in fault planes where large rupture energy is released (e.g. Schorlemmer & Wiemer 2005). However, it still remains uncertain whether the b values of events prior to coming large earthquakes are always low significantly. To clarify this issue, we conducted a systematic investigation into b values prior to large earthquakes in the Japanese Mainland. Since no physical definition of mainshock, foreshock, and aftershock is known, we simply investigated b values of the events with magnitudes larger than the lower-cutoff magnitude, Mc, prior to earthquakes equal to or larger than a threshold magnitude, Mth, where Mth>Mc. Schorlemmer et al. (2005) showed that the b value for different fault types differs significantly, which is supposed to reflect the feature that the fracture stress depends on fault types. Therefore, we classified fault motions into normal, strike-slip, and thrust types based on the mechanism solution of earthquakes, and computed b values of events associated with each fault motion separately. We found that the target events (M≥Mth) and the events that occurred prior to the target events both show a common systematic change in b: normal faulting events have the highest b values, thrust events the lowest and strike-slip events intermediate values. Moreover, we found that the b values for the prior events (M≥Mc) are significantly lower than the b values for the target events (M≥Mth), though their b values change somewhat depending on the choice of the parameter values to define the target events (M≥Mth) and the prior events (M≥Mc). This finding indicates that the b value could be used as an effective index for foreseeing occurrence of large earthquakes, if the parameter values are well-tuned.
Anemia and Iron Deficiency in Children With Potential Celiac Disease.
Repo, Marleena; Lindfors, Katri; Mäki, Markku; Huhtala, Heini; Laurila, Kaija; Lähdeaho, Marja-Leena; Saavalainen, Päivi; Kaukinen, Katri; Kurppa, Kalle
2017-01-01
Active screening for celiac disease frequently detects seropositive children with normal villous morphology (potential celiac disease). It remains unclear whether these subjects should be treated. We here investigated the prevalence of anemia and iron deficiency in children with potential and mucosal atrophy celiac disease. The prospective study involved 19 children with potential disease, 67 with partial or subtotal villous atrophy (P/SVA), and 16 with total villous atrophy (TVA). Twenty-three healthy children comprised the control group. The groups were compared for various clinical, histological, and laboratory parameters and hepcidin. The prevalence of abnormal parameters was as follows (controls, potential celiac disease, P/SVA, and TVA, respectively): anemia 0%, 15%, 22%, and 63%; low iron 5%, 0%, 14%, and 50%; increased transferrin receptor 1 5%, 16%, 20%, and 47%; low ferritin 0%, 21%, 35%, and 87%; and low transferrin saturation 10%, 11%, 41%, and 71%. One subject had low folate and none had low vitamin B12. The median values for hemoglobin, total iron, ferritin, and transferrin saturation were significantly lower and transferrin receptor 1 values higher in TVA group compared with other groups. After a median of 7 months on a gluten-free diet hemoglobin, total iron, ferritin, and albumin in children with P/SVA exceeded the baseline values in the potential celiac disease group. The development of anemia and iron deficiency in celiac disease is a continuum and may already be present in children with normal villous morphology, advocating an early diagnosis and possible dietary treatment of these patients.
Lauer, Michael S; Pothier, Claire E; Magid, David J; Smith, S Scott; Kattan, Michael W
2007-12-18
The exercise treadmill test is recommended for risk stratification among patients with intermediate to high pretest probability of coronary artery disease. Posttest risk stratification is based on the Duke treadmill score, which includes only functional capacity and measures of ischemia. To develop and externally validate a post-treadmill test, multivariable mortality prediction rule for adults with suspected coronary artery disease and normal electrocardiograms. Prospective cohort study conducted from September 1990 to May 2004. Exercise treadmill laboratories in a major medical center (derivation set) and a separate HMO (validation set). 33,268 patients in the derivation set and 5821 in the validation set. All patients had normal electrocardiograms and were referred for evaluation of suspected coronary artery disease. The derivation set patients were followed for a median of 6.2 years. A nomogram-illustrated model was derived on the basis of variables easily obtained in the stress laboratory, including age; sex; history of smoking, hypertension, diabetes, or typical angina; and exercise findings of functional capacity, ST-segment changes, symptoms, heart rate recovery, and frequent ventricular ectopy in recovery. The derivation data set included 1619 deaths. Although both the Duke treadmill score and our nomogram-illustrated model were significantly associated with death (P < 0.001), the nomogram was better at discrimination (concordance index for right-censored data, 0.83 vs. 0.73) and calibration. We reclassified many patients with intermediate- to high-risk Duke treadmill scores as low risk on the basis of the nomogram. The model also predicted 3-year mortality rates well in the validation set: Based on an optimal cut-point for a negative predictive value of 0.97, derivation and validation rates were, respectively, 1.7% and 2.5% below the cut-point and 25% and 29% above the cut-point. Blood test-based measures or left ventricular ejection fraction were not included. The nomogram can be applied only to patients with a normal electrocardiogram. Clinical utility remains to be tested. A simple nomogram based on easily obtained pretest and exercise test variables predicted all-cause mortality in adults with suspected coronary artery disease and normal electrocardiograms.
Dauchy, Robert T; Dupepe, Lynell M; Ooms, Tara G; Dauchy, Erin M; Hill, Cody R; Mao, Lulu; Belancio, Victoria P; Slakey, Lauren M; Hill, Steven M; Blask, David E
2011-05-01
Appropriate laboratory animal facility lighting and lighting protocols are essential for maintaining the health and wellbeing of laboratory animals and ensuring the credible outcome of scientific investigations. Our recent experience in relocating to a new laboratory facility illustrates the importance of these considerations. Previous studies in our laboratory demonstrated that animal room contamination with light-at-night (LAN) of as little as 0.2 lx at rodent eye level during an otherwise normal dark-phase disrupted host circadian rhythms and stimulated the metabolism and proliferation of human cancer xenografts in rats. Here we examined how simple improvements in facility design at our new location completely eliminated dark-phase LAN contamination and restored normal circadian rhythms in nontumor-bearing rats and normal tumor metabolism and growth in host rats bearing tissue-isolated MCF7(SR(-)) human breast tumor xenografts or 7288CTC rodent hepatomas. Reducing LAN contamination in the animal quarters from 24.5 ± 2.5 lx to nondetectable levels (complete darkness) restored normal circadian regulation of rodent arterial blood melatonin, glucose, total fatty and linoleic acid concentrations, tumor uptake of O(2), glucose, total fatty acid and CO(2) production and tumor levels of cAMP, triglycerides, free fatty acids, phospholipids, and cholesterol esters, as well as extracellular-signal-regulated kinase, mitogen-activated protein kinase, serine-threonine protein kinase, glycogen synthase kinase 3β, γ-histone 2AX, and proliferating cell nuclear antigen.
Dauchy, Robert T; Dupepe, Lynell M; Ooms, Tara G; Dauchy, Erin M; Hill, Cody R; Mao, Lulu; Belancio, Victoria P; Slakey, Lauren M; Hill, Steven M; Blask, David E
2011-01-01
Appropriate laboratory animal facility lighting and lighting protocols are essential for maintaining the health and wellbeing of laboratory animals and ensuring the credible outcome of scientific investigations. Our recent experience in relocating to a new laboratory facility illustrates the importance of these considerations. Previous studies in our laboratory demonstrated that animal room contamination with light-at-night (LAN) of as little as 0.2 lx at rodent eye level during an otherwise normal dark-phase disrupted host circadian rhythms and stimulated the metabolism and proliferation of human cancer xenografts in rats. Here we examined how simple improvements in facility design at our new location completely eliminated dark-phase LAN contamination and restored normal circadian rhythms in nontumor-bearing rats and normal tumor metabolism and growth in host rats bearing tissue-isolated MCF7(SR–) human breast tumor xenografts or 7288CTC rodent hepatomas. Reducing LAN contamination in the animal quarters from 24.5 ± 2.5 lx to nondetectable levels (complete darkness) restored normal circadian regulation of rodent arterial blood melatonin, glucose, total fatty and linoleic acid concentrations, tumor uptake of O2, glucose, total fatty acid and CO2 production and tumor levels of cAMP, triglycerides, free fatty acids, phospholipids, and cholesterol esters, as well as extracellular-signal-regulated kinase, mitogen-activated protein kinase, serine–threonine protein kinase, glycogen synthase kinase 3β, γ-histone 2AX, and proliferating cell nuclear antigen. PMID:21640027
Sinigalliano, Christopher D.; Ervin, Jared S.; Van De Werfhorst, Laurie C.; Badgley, Brian D.; Ballestée, Elisenda; Bartkowiaka, Jakob; Boehm, Alexandria B.; Byappanahalli, Muruleedhara N.; Goodwin, Kelly D.; Gourmelon, Michèle; Griffith, John; Holden, Patricia A.; Jay, Jenny; Layton, Blythe; Lee, Cheonghoon; Lee, Jiyoung; Meijer, Wim G.; Noble, Rachel; Raith, Meredith; Ryu, Hodon; Sadowsky, Michael J.; Schriewer, Alexander; Wang, Dan; Wanless, David; Whitman, Richard; Wuertz, Stefan; Santo Domingo, Jorge W.
2013-01-01
Here we report results from a multi-laboratory (n = 11) evaluation of four different PCR methods targeting the 16S rRNA gene of Catellicoccus marimammalium originally developed to detect gull fecal contamination in coastal environments. The methods included a conventional end-point PCR method, a SYBR® Green qPCR method, and two TaqMan® qPCR methods. Different techniques for data normalization and analysis were tested. Data analysis methods had a pronounced impact on assay sensitivity and specificity calculations. Across-laboratory standardization of metrics including the lower limit of quantification (LLOQ), target detected but not quantifiable (DNQ), and target not detected (ND) significantly improved results compared to results submitted by individual laboratories prior to definition standardization. The unit of measure used for data normalization also had a pronounced effect on measured assay performance. Data normalization to DNA mass improved quantitative method performance as compared to enterococcus normalization. The MST methods tested here were originally designed for gulls but were found in this study to also detect feces from other birds, particularly feces composited from pigeons. Sequencing efforts showed that some pigeon feces from California contained sequences similar to C. marimammalium found in gull feces. These data suggest that the prevalence, geographic scope, and ecology of C. marimammalium in host birds other than gulls require further investigation. This study represents an important first step in the multi-laboratory assessment of these methods and highlights the need to broaden and standardize additional evaluations, including environmentally relevant target concentrations in ambient waters from diverse geographic regions.
Herzog, Bastian; Lemmer, Hilde; Horn, Harald; Müller, Elisabeth
2014-02-22
Evaluation of xenobiotics biodegradation potential, shown here for benzotriazoles (corrosion inhibitors) and sulfamethoxazole (sulfonamide antibiotic) by microbial communities and/or pure cultures normally requires time intensive and money consuming LC/GC methods that are, in case of laboratory setups, not always needed. The usage of high concentrations to apply a high selective pressure on the microbial communities/pure cultures in laboratory setups, a simple UV-absorbance measurement (UV-AM) was developed and validated for screening a large number of setups, requiring almost no preparation and significantly less time and money compared to LC/GC methods. This rapid and easy to use method was evaluated by comparing its measured values to LC-UV and GC-MS/MS results. Furthermore, its application for monitoring and screening unknown activated sludge communities (ASC) and mixed pure cultures has been tested and approved to detect biodegradation of benzotriazole (BTri), 4- and 5-tolyltriazole (4-TTri, 5-TTri) as well as SMX. In laboratory setups, xenobiotics concentrations above 1.0 mg L(-1) without any enrichment or preparation could be detected after optimization of the method. As UV-AM does not require much preparatory work and can be conducted in 96 or even 384 well plate formats, the number of possible parallel setups and screening efficiency was significantly increased while analytic and laboratory costs were reduced to a minimum.
2014-01-01
Background Evaluation of xenobiotics biodegradation potential, shown here for benzotriazoles (corrosion inhibitors) and sulfamethoxazole (sulfonamide antibiotic) by microbial communities and/or pure cultures normally requires time intensive and money consuming LC/GC methods that are, in case of laboratory setups, not always needed. Results The usage of high concentrations to apply a high selective pressure on the microbial communities/pure cultures in laboratory setups, a simple UV-absorbance measurement (UV-AM) was developed and validated for screening a large number of setups, requiring almost no preparation and significantly less time and money compared to LC/GC methods. This rapid and easy to use method was evaluated by comparing its measured values to LC-UV and GC-MS/MS results. Furthermore, its application for monitoring and screening unknown activated sludge communities (ASC) and mixed pure cultures has been tested and approved to detect biodegradation of benzotriazole (BTri), 4- and 5-tolyltriazole (4-TTri, 5-TTri) as well as SMX. Conclusions In laboratory setups, xenobiotics concentrations above 1.0 mg L-1 without any enrichment or preparation could be detected after optimization of the method. As UV-AM does not require much preparatory work and can be conducted in 96 or even 384 well plate formats, the number of possible parallel setups and screening efficiency was significantly increased while analytic and laboratory costs were reduced to a minimum. PMID:24558966
Medical Service Clinical Laboratory Procedure--Hematology.
ERIC Educational Resources Information Center
Department of the Army, Washington, DC.
Presented are laboratory studies focusing on blood cells and the complete scheme of blood coagulation. Formed is the basis for the following types of laboratory operations: (1) distinguishing the morphology of normal and abnormal blood cells; (2) measuring the concentrations or number of blood cells; (3) measuring concentration and detecting…
Hypervitaminosis D in Guinea Pigs with α-Mannosidosis
Jensen, JanLee A; Brice, Angela K; Bagel, Jessica H; Mexas, Angela M; Yoon, Sea Young; Wolfe, John H
2013-01-01
A colony of guinea pigs (n = 9) with α-mannosidosis was fed a pelleted commercial laboratory guinea pig diet. Over 2 mo, all 9 guinea pigs unexpectedly showed anorexia and weight loss (11.7% to 30.0% of baseline weight), and 3 animals demonstrated transient polyuria and polydipsia. Blood chemistry panels in these 3 guinea pigs revealed high-normal total calcium, high-normal phosphate, and high ALP. Urine specific gravity was dilute (1.003, 1.009, 1.013) in the 3 animals tested. Postmortem examination of 7 animals that were euthanized after failing to respond to supportive care revealed renal interstitial fibrosis with tubular mineralization, soft tissue mineralization in multiple organs, hepatic lipidosis, and pneumonia. Analysis of the pelleted diet revealed that it had been formulated with a vitamin D3 content of more than 150 times the normal concentration. Ionized calcium and 25-hydroxyvitamin D values were both high in serum saved from 2 euthanized animals, confirming the diagnosis of hypervitaminosis D. This report discusses the clinical signs, blood chemistry results, and gross and histologic findings of hypervitaminosis D in a colony of guinea pigs. When unexpected signs occur colony-wide, dietary differentials should be investigated at an early time point. PMID:23582422
Hypervitaminosis D in guinea pigs with α-mannosidosis.
Jensen, Janlee A; Brice, Angela K; Bagel, Jessica H; Mexas, Angela M; Yoon, Sea Young; Wolfe, John H
2013-04-01
A colony of guinea pigs (n = 9) with α-mannosidosis was fed a pelleted commercial laboratory guinea pig diet. Over 2 mo, all 9 guinea pigs unexpectedly showed anorexia and weight loss (11.7% to 30.0% of baseline weight), and 3 animals demonstrated transient polyuria and polydipsia. Blood chemistry panels in these 3 guinea pigs revealed high-normal total calcium, high-normal phosphate, and high ALP. Urine specific gravity was dilute (1.003, 1.009, 1.013) in the 3 animals tested. Postmortem examination of 7 animals that were euthanized after failing to respond to supportive care revealed renal interstitial fibrosis with tubular mineralization, soft tissue mineralization in multiple organs, hepatic lipidosis, and pneumonia. Analysis of the pelleted diet revealed that it had been formulated with a vitamin D3 content of more than 150 times the normal concentration. Ionized calcium and 25-hydroxyvitamin D values were both high in serum saved from 2 euthanized animals, confirming the diagnosis of hypervitaminosis D. This report discusses the clinical signs, blood chemistry results, and gross and histologic findings of hypervitaminosis D in a colony of guinea pigs. When unexpected signs occur colony-wide, dietary differentials should be investigated at an early time point.
National survey on critical values reporting in a cohort of Italian laboratories.
Lippi, Giuseppe; Giavarina, Davide; Montagnana, Martina; Luca Salvagno, Gian; Cappelletti, Piero; Plebani, Mario; Guidi, Gian Cesare
2007-01-01
Critical values' reporting is an essential requisite for clinical laboratories. Local policies were investigated within an indicative cohort of Italian laboratories to monitor the situation and establish a performance benchmark. A five-point questionnaire was administered to 150 laboratory specialists attending the SIMEL (Italian Society of Laboratory Medicine) National Meeting in June 2006. A total of 107 questionnaires (71.3%) were returned with a 100% individual question response rate. Only 55% of the participants acknowledge critical values reporting as an essential practice, 80% admit that a comprehensive list of critical values is unavailable in the laboratory and 4% do not promptly communicate critical values. The list of critical values is variable among laboratories, ranging from none to 20 analytes included. The requesting physician or his/her office staff receives the great majority (97%) of notifications by telephone for outpatients. Critical values for inpatients are notified directly by telephone (81%) and in a minority of cases by either fax or computer (19%). In the inpatient setting, the information is notified to physicians (77%), nurses (15%) or other healthcare staff in the clinic (8%). It was found that 49% of the participants adopt a standard (digital or written) policy for routine recording of notifications; in 32% of the cases the registration is left to individual attitudes, whereas in 20% of the cases the notification is not recorded. No laboratory has yet adopted a read-back verification of the complete test result by the person receiving the information. The importance of critical value reporting is still poorly recognized in Italy and uniform or internationally accredited practices for communication and recording are not currently implemented.
Short-Term Global Horizontal Irradiance Forecasting Based on Sky Imaging and Pattern Recognition
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hodge, Brian S; Feng, Cong; Cui, Mingjian
Accurate short-term forecasting is crucial for solar integration in the power grid. In this paper, a classification forecasting framework based on pattern recognition is developed for 1-hour-ahead global horizontal irradiance (GHI) forecasting. Three sets of models in the forecasting framework are trained by the data partitioned from the preprocessing analysis. The first two sets of models forecast GHI for the first four daylight hours of each day. Then the GHI values in the remaining hours are forecasted by an optimal machine learning model determined based on a weather pattern classification model in the third model set. The weather pattern ismore » determined by a support vector machine (SVM) classifier. The developed framework is validated by the GHI and sky imaging data from the National Renewable Energy Laboratory (NREL). Results show that the developed short-term forecasting framework outperforms the persistence benchmark by 16% in terms of the normalized mean absolute error and 25% in terms of the normalized root mean square error.« less
Cerebral blood flow is reduced in patients with sepsis syndrome
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bowton, D.L.; Bertels, N.H.; Prough, D.S.
The relationship between sepsis-induced CNS dysfunction and changes in brain blood flow remains unknown, and animal studies examining the influence of sepsis on cerebral blood flow (CBF) do not satisfactorily address that relationship. We measured CBF and cerebrovascular reactivity to CO/sub 2/ in nine patients with sepsis syndrome using the /sup 133/Xe clearance technique. Mean CBF was 29.6 +/- 15.8 (SD) ml/100 g.min, significantly lower than the normal age-matched value in this laboratory of 44.9 +/- 6.2 ml/100 g.min (p less than .02). This depression did not correlate with changes in mean arterial pressure. Despite the reduction in CBF, themore » specific reactivity of the cerebral vasculature to changes in CO/sub 2/ was normal, 1.3 +/- 0.9 ml/100 g.min/mm Hg. Brain blood flow is reduced in septic humans; the contribution of this reduction to the metabolic and functional changes observed in sepsis requires further study.« less
Matsumura, Kenta; Yamakoshi, Takehiro
2013-12-01
Heart rate (HR) and normalized pulse volume (NPV) are physiological indices that have been used in a diversity of psychological studies. However, measuring these indices often requires laborious processes. We therefore developed a new smartphone program, named iPhysioMeter, that makes it possible to measure beat-by-beat HR and ln NPV using only a smartphone. We examined its accuracy against conventional laboratory measures. Mental stress tasks were used to alter HR and ln NPV in 12 participants. Bland-Altman analyses revealed negligible proportional bias for HR and ln NPV or for their change values, expressed as ΔHR and Δln NPV. However, a relatively large fixed bias did emerge for ln NPV, as well as a small one for Δln NPV, although both were within the limits of agreement. These findings suggest that iPhysioMeter can yield valid measures of the absolute level of HR and of relative changes in ln NPV.
NASA Astrophysics Data System (ADS)
Haines, Samuel; Marone, Chris; Saffer, Demian
2014-12-01
The mechanics of slip on low-angle normal faults (LANFs) remain an enduring problem in structural geology and fault mechanics. In most cases, new faults should form rather than having slip occur on LANFs, assuming values of fault friction consistent with Byerlee's Law. We present results of laboratory measurements on the frictional properties of natural clay-rich gouges from low-angle normal faults (LANF) in the American Cordillera, from the Whipple Mts. Detachment, the Panamint range-front detachment, and the Waterman Hills detachment. These clay-rich gouges are dominated by neoformed clay minerals and are an integral part of fault zones in many LANFs, yet their frictional properties under in situ conditions remain relatively unknown. We conducted measurements under saturated and controlled pore pressure conditions at effective normal stresses ranging from 20 to 60 MPa (corresponding to depths of 0.9-2.9 km), on both powdered and intact wafers of fault rock. For the Whipple Mountains detachment, friction coefficient (μ) varies depending on clast content, with values ranging from 0.40 to 0.58 for clast-rich material, and 0.29-0.30 for clay-rich gouge. Samples from the Panamint range-front detachment were clay-rich, and exhibit friction values of 0.28 to 0.38, significantly lower than reported from previous studies on fault gouges tested under room humidity (nominally dry) conditions, including samples from the same exposure. Samples from the Waterman Hills detachment are slightly stronger, with μ ranging from 0.38 to 0.43. The neoformed gouge materials from all three localities exhibits velocity-strengthening frictional behavior under almost all of the experimental conditions we explored, with values of the friction rate parameter (a - b) ranging from -0.001 to +0.025. Clast-rich samples exhibited frictional healing (strength increases with hold time), whereas clay-rich samples do not. Our results indicate that where clay-rich neoformed gouges are present along LANFs, they provide a mechanically viable explanation for slip on faults with dips <20°, requiring only moderate (Pf <σ3) overpressures and/or correcting for ∼5° of footwall tilting. Furthermore, the low rates of frictional strength recovery and velocity-strengthening frictional behavior we observe provide an explanation for the lack of observed seismicity on these structures. We suggest that LANFs in the upper crust (depth <8 km) slip via a combination of a) reaction-weakening of initially high-angle fault zones by the formation of neoformed clay-rich gouges, and b) regional tectonic accommodation of rotating fault blocks.
Wassenaar, L I; Terzer-Wassmuth, S; Douence, C; Araguas-Araguas, L; Aggarwal, P K; Coplen, T B
2018-03-15
Water stable isotope ratios (δ 2 H and δ 18 O values) are widely used tracers in environmental studies; hence, accurate and precise assays are required for providing sound scientific information. We tested the analytical performance of 235 international laboratories conducting water isotope analyses using dual-inlet and continuous-flow isotope ratio mass spectrometers and laser spectrometers through a water isotope inter-comparison test. Eight test water samples were distributed by the IAEA to international stable isotope laboratories. These consisted of a core set of five samples spanning the common δ-range of natural waters, and three optional samples (highly depleted, enriched, and saline). The fifth core sample contained unrevealed trace methanol to assess analyst vigilance to the impact of organic contamination on water isotopic measurements made by all instrument technologies. For the core and optional samples ~73 % of laboratories gave acceptable results within 0.2 ‰ and 1.5 ‰ of the reference values for δ 18 O and δ 2 H, respectively; ~27 % produced unacceptable results. Top performance for δ 18 O values was dominated by dual-inlet IRMS laboratories; top performance for δ 2 H values was led by laser spectrometer laboratories. Continuous-flow instruments yielded comparatively intermediate results. Trace methanol contamination of water resulted in extreme outlier δ-values for laser instruments, but also affected reactor-based continuous-flow IRMS systems; however, dual-inlet IRMS δ-values were unaffected. Analysis of the laboratory results and their metadata suggested inaccurate or imprecise performance stemmed mainly from skill- and knowledge-based errors including: calculation mistakes, inappropriate or compromised laboratory calibration standards, poorly performing instrumentation, lack of vigilance to contamination, or inattention to unreasonable isotopic outcomes. To counteract common errors, we recommend that laboratories include 1-2 'known' control standards in all autoruns; laser laboratories should screen each autorun for spectral contamination; and all laboratories should evaluate whether derived d-excess values are realistic when both isotope ratios are measured. Combined, these data evaluation strategies should immediately inform the laboratory about fundamental mistakes or compromised samples. Copyright © 2018 John Wiley & Sons, Ltd.
Wassenaar, L. I.; Terzer-Wassmuth, S.; Douence, C.; Araguas-Araguas, L.; Aggarwal, P. K.; Coplen, Tyler B.
2018-01-01
RationaleWater stable isotope ratios (δ2H and δ18O values) are widely used tracers in environmental studies; hence, accurate and precise assays are required for providing sound scientific information. We tested the analytical performance of 235 international laboratories conducting water isotope analyses using dual-inlet and continuous-flow isotope ratio mass spectrometers and laser spectrometers through a water isotope inter-comparison test.MethodsEight test water samples were distributed by the IAEA to international stable isotope laboratories. These consisted of a core set of five samples spanning the common δ-range of natural waters, and three optional samples (highly depleted, enriched, and saline). The fifth core sample contained unrevealed trace methanol to assess analyst vigilance to the impact of organic contamination on water isotopic measurements made by all instrument technologies.ResultsFor the core and optional samples ~73 % of laboratories gave acceptable results within 0.2 ‰ and 1.5 ‰ of the reference values for δ18O and δ2H, respectively; ~27 % produced unacceptable results. Top performance for δ18O values was dominated by dual-inlet IRMS laboratories; top performance for δ2H values was led by laser spectrometer laboratories. Continuous-flow instruments yielded comparatively intermediate results. Trace methanol contamination of water resulted in extreme outlier δ-values for laser instruments, but also affected reactor-based continuous-flow IRMS systems; however, dual-inlet IRMS δ-values were unaffected.ConclusionsAnalysis of the laboratory results and their metadata suggested inaccurate or imprecise performance stemmed mainly from skill- and knowledge-based errors including: calculation mistakes, inappropriate or compromised laboratory calibration standards, poorly performing instrumentation, lack of vigilance to contamination, or inattention to unreasonable isotopic outcomes. To counteract common errors, we recommend that laboratories include 1–2 'known' control standards in all autoruns; laser laboratories should screen each autorun for spectral contamination; and all laboratories should evaluate whether derived d-excess values are realistic when both isotope ratios are measured. Combined, these data evaluation strategies should immediately inform the laboratory about fundamental mistakes or compromised samples.
Seo, Yu-Mi; Kang, Hyun-Mi; Lee, Sung-Churl; Yu, Jae-Won; Kil, Hong-Ryang; Rhim, Jung-Woo; Han, Ji-Whan; Lee, Kyung-Yil
2018-05-01
This study aimed to analyse laboratory values according to fever duration, and evaluate the relationship across these values during the acute phase of Kawasaki disease (KD) to aid in the early diagnosis for early-presenting KD and incomplete KD patients. Clinical and laboratory data of patients with KD (n=615) were evaluated according to duration of fever at presentation, and were compared between patients with and without coronary artery lesions (CALs). For evaluation of the relationships across laboratory indices, patients with a fever duration of 5 days or 6 days were used (n=204). The mean fever duration was 6.6±2.3 days, and the proportions of patients with CALs was 19.3% (n=114). C-reactive proteins (CRPs) and neutrophil differential values were highest and hemoglobin, albumin, and lymphocyte differential values were lowest in the 6-day group. Patients with CALs had longer total fever duration, higher CRP and neutrophil differential values and lower hemoglobin and albumin values compared to patients without CALs. CRP, albumin, neutrophil differential, and hemoglobin values at the peak inflammation stage of KD showed positive or negative correlations each other. The severity of systemic inflammation in KD was reflected in the laboratory values including CRP, neutrophil differential, albumin, and hemoglobin. Observing changes in these laboratory parameters by repeated examinations prior to the peak of inflammation in acute KD may aid in diagnosis of early-presenting KD patients.
Cone, Catherine J; Bachyrycz, Amy M; Murata, Glen H
2010-10-01
To report a case of idiosyncratic hepatotoxicity associated with metformin in the treatment of type 2 diabetes with nonalcoholic fatty liver disease (NAFLD). A 61-year-old obese man presented with jaundice, nausea, fatigue, and an unintentional weight loss 2 weeks following initiation of metformin. Laboratory findings revealed aminotransferase values 10-15 times the upper limit of normal. Potential causative agents, including metformin, simvastatin, and Niaspan (extended-release niacin), were discontinued. Two months later, the patient's signs and symptoms had resolved and aminotransferase values returned to normal. An objective causality assessment revealed that the adverse reaction was probably associated with metformin. Since numerous medications and disease states can cause abnormalities in liver enzymes, it is important for providers to be able to distinguish the cause(s) and take appropriate actions. This can take a great deal of time and effort in patients with multiple medications and comorbidities. In this patient's case, viral hepatitis, worsening NAFLD, and the concomitant drugs were highly suspected. As hydroxymethylglutaryl coenzyme A reductase inhibitors offer substantial cardiovascular benefits and as metformin is a first-line agent in helping to lower blood glucose concentrations and to normalize the metabolic profile in type 2 diabetes, reintroduction of metformin and simvastatin would likely be beneficial. This is a case report of metformin-induced hepatotoxicity. As the prevalence of type 2 diabetes and subsequent metabolic effects increases in the US, metformin use will likewise increase. As potential for increased idiosyncratic hepatotoxicity associated with metformin use is likely to occur, clinicians should be vigilant.
Kim, Beom Kyung; Kim, Seung Up; Choi, Gi Hong; Han, Woong Kyu; Park, Mi Sung; Kim, Eun Hye; Park, Jun Yong; Kim, Do Young; Choi, Jin Sub; Yang, Seung Choul; Choi, Eun Hee; Song, Kijun; Ahn, Sang Hoon; Han, Kwang-Hyub; Chon, Chae Yoon
2012-04-01
Liver stiffness (LS) measurement can distinguish individuals with potential liver disease (LD) from the general population. However, if LS is sex-sensitive, prevalence of LD may be incorrectly estimated when the same reference LS value is applied irrespective of sex. Here, we evaluated whether normal ranges of LS differ between healthy men and women. LS was measured in a cohort of healthy living liver and kidney donors, none of whom suffered from diabetes mellitus, hypertension, hepatitis B or C virus infection, heart or liver dysfunction, or metabolic syndrome. Patients with abnormal laboratory findings related to potential LD (platelet count < 150 × 10(3) /µL; aspartate aminotransferase > 40 IU/L; alanine aminotransferase [ALT] > 40 IU/L; albumin < 3.3 g/dL; total bilirubin > 1.2 mg/dL; gamma-glutamyl transpeptidase > 54 IU/L; alkaline phosphatase > 115 IU/L) were excluded. Among 242 patients analyzed, the mean age was 34.1 for men (n = 121) and 40.5 years for women (n = 121) (P < 0.001). Men had a higher mean LS value than women (5.2 ± 1.2 vs 4.8 ± 1.1 kPa/P < 0.001). Multivariate-linear regression analysis identified sex as the only independent factor for LS values (β = 0.361/P = 0.021). Using the 5th-95th percentiles, we determined normal LS ranges of 3.7-7.0 kPa in men and 3.3-6.8 kPa in women. In subgroups with ALT < 30 IU/L (subgroup-1, n = 216) and ALT < 20 IU/L (subgroup-2, n = 163), men had significantly higher LS values than women (5.2 ± 1.3 vs 4.7 ± 1.1 kPa/P = 0.003 and 5.1 ± 1.2 vs 4.7 ± 1.1 kPa/P = 0.030, respectively), demonstrating an independent sex effect (β = 0.483/P = 0.003 and β = 0.389/P = 0.030, respectively). An independent sex effect on LS values was confirmed. Thus, sex-specific references should be used for effective screening based on LS measurements. © 2011 Journal of Gastroenterology and Hepatology Foundation and Blackwell Publishing Asia Pty Ltd.
Normal range of hepatic fat fraction on dual- and triple-echo fat quantification MR in children.
Shin, Hyun Joo; Kim, Hyun Gi; Kim, Myung-Joon; Koh, Hong; Kim, Ha Yan; Roh, Yun Ho; Lee, Mi-Jung
2015-01-01
To evaluate hepatic fat fraction on dual- and triple-echo gradient-recalled echo MRI sequences in healthy children. We retrospectively reviewed the records of children in a medical check-up clinic from May 2012 to November 2013. We excluded children with abnormal laboratory findings or those who were overweight. Hepatic fat fraction was measured on dual- and triple-echo sequences using 3T MRI. We compared fat fractions using the Wilcoxon signed rank test and the Bland-Altman 95% limits of agreement. The correlation between fat fractions and clinical and laboratory findings was evaluated using Spearman's correlation test, and the cut-off values of fat fractions for diagnosing fatty liver were obtained from reference intervals. In 54 children (M:F = 26:28; 5-15 years; mean 9 years), the dual fat fraction (0.1-8.0%; median 1.6%) was not different from the triple fat fraction (0.4-6.5%; median 2.7%) (p = 0.010). The dual- and triple-echo fat fractions showed good agreement using a Bland-Altman plot (-0.6 ± 2.8%). Eight children (14.8%) on dual-echo sequences and six (11.1%) on triple-echo sequences had greater than 5% fat fraction. From these children, six out of eight children on dual-echo sequences and four out of six children on triple-echo sequences had a 5-6% hepatic fat fraction. When using a cut-off value of a 6% fat fraction derived from a reference interval, only 3.7% of children were diagnosed with fatty liver. There was no significant correlation between clinical and laboratory findings with dual and triple-echo fat fractions. Dual fat fraction was not different from triple fat fraction. We suggest a cut-off value of a 6% fat fraction is more appropriate for diagnosing fatty liver on both dual- and triple-echo sequences in children.
McHale, Michael R.; McChesney, Dennis
2007-01-01
In 2003, a study was conducted to evaluate the accuracy and precision of 10 laboratories that analyze water-quality samples for phosphorus concentrations in the Catskill Mountain region of New York State. Many environmental studies in this region rely on data from these different laboratories for water-quality analyses, and the data may be used in watershed modeling and management decisions. Therefore, it is important to determine whether the data reported by these laboratories are of comparable accuracy and precision. Each laboratory was sent 12 samples for triplicate analysis for total phosphorus, total dissolved phosphorus, and soluble reactive phosphorus. Eight of these laboratories reported results that met comparability criteria for all samples; the remaining two laboratories met comparability criteria for only about half of the analyses. Neither the analytical method used nor the sample concentration ranges appeared to affect the comparability of results. The laboratories whose results were comparable gave consistently comparable results throughout the concentration range analyzed, and the differences among methods did not diminish comparability. All laboratories had high data precision as indicated by sample triplicate results. In addition, the laboratories consistently reported total phosphorus values greater than total dissolved phosphorus values, and total dissolved phosphorus values greater than soluble reactive phosphorus values, as would be expected. The results of this study emphasize the importance of regular laboratory participation in sample-exchange programs.
Laboratory Indices of Nutritional Status in Pregnancy. Summary Report.
ERIC Educational Resources Information Center
National Academy of Sciences-National Research Council, Washington, DC. Food and Nutrition Board.
This report, a condensation of a publication titled "Laboratory Indices of Nutritional Status in Pregnancy," summarizes the effects of normal gestation on certain laboratory indices of nutritional and metabolic status in an effort to provide the clinician with normative data applicable to healthy pregnant women. The report is divided into six…
Bruno, Oscar D; Rossi, María A; Juárez-Allen, Lea; Serra, Héctor A; Albiero, María C
2015-01-01
The aim of this study was to investigate interchangeability of two tests to diagnose Cushing's syndrome. We compared 10:00-11:00 PM urinary free cortisol/creatinine ratio (UFC/Cr) with late night 11:00 PM salivary cortisol (LNSC) in normal and obese controls vs. patients with Cushing's syndrome. Mean UFC/Cr did not differ between 69 normal and 62 obese controls (9.9 ± 7.9 vs. 9.7 ± 9.3) whereas 116 Cushing's patients had significantly higher values (277.0 ± 318.0; z: -11.1 and -10.2, respectively; p < 0.001). LNSC was 1.9 ± 1.2 nmol/l in 44 normal and 2.5 ± 1.6 in 45 obese subjects with no differences between them, but was significantly higher in 47 Cushing's patients (24.8 ± 23.3; z: -7.22 and -6.96, respectively, p < 0.001). Comparison of UFC/Cr and LNSC in samples obtained simultaneously showed that UFC/Cr was 12.0 ± 8.7 ng cortisol/mg creatinine in 34 normal, 12.3 ± 8.9 in 40 obese and 319.5 ± 333.4 in 35 CS subjects (p < 0.001 vs. normal and obese), whereas LNSC was 1.8 ± 1.2 nmol/l in normal, 2.6 ± 1.7 in obese and 24.6 ± 17.4 in CS patients (p < 0.001 vs. normal and obese); ROC curves showed comparable high sensitivity and specificity figures for the diagnosis of CS. We concluded that UFC/Cr test is easy to perform, readily available in routine laboratories, has high sensitivity and specificity, and offers a valuable alternative to LNSC in the study of Cushing's syndrome.
Environmental parameters of shuttle support for life sciences experiments
NASA Technical Reports Server (NTRS)
Waligora, J. M.
1976-01-01
The environments provided by the Orbiter vehicle and by the Spacelab will differ substantially from the environment provided by prior spacecraft. The specific design limits for each environmental parameter and expected operating characteristics are presented for both the Orbiter and the Spacelab. The environments are compared with those of earlier spacecraft and with the normal earth laboratory. Differences between the spacecraft environments and the normal laboratory environment and the impact of these differences on experiments and equipment design are discussed.
Investigations of magnesium, histamine and immunoglobulins dynamics in acute urticaria.
Mureşan, D; Oană, A; Nicolae, I; Alecu, M; Moşescu, L; Benea, V; Flueraş, M
1990-01-01
In 42 urticaria patients, magnesium, histamine and IgE were dosed. Magnesium, IgE and histamine variations were followed in urticaria evolution, during acute phase and clinical remission. We noticed magnesium, histamine, IgE values variations depending on disease evolution and applied therapeutic scheme. Therefore: At disease starting point, histamine presented 3.5 times higher values than the normal ones. The value decreases following a curve which tends to reach normal values during clinical remission. At disease starting point, magnesium presented values under the inferior limit of the normal, 0.5 m mol/L respectively, as a mean. The value increases towards the normal limit during clinical remission. Immunoglobulins E follow a similar curve to histamine one, presenting 1,250 U/L values at the starting point, that, under medication, influence decrease between normal limits (800 U/L), during clinical remission. Analyzing the variations of biochemical parameters, the authors emphasize magnesium substitution treatment in urticaria.
Statistical Bayesian method for reliability evaluation based on ADT data
NASA Astrophysics Data System (ADS)
Lu, Dawei; Wang, Lizhi; Sun, Yusheng; Wang, Xiaohong
2018-05-01
Accelerated degradation testing (ADT) is frequently conducted in the laboratory to predict the products’ reliability under normal operating conditions. Two kinds of methods, degradation path models and stochastic process models, are utilized to analyze degradation data and the latter one is the most popular method. However, some limitations like imprecise solution process and estimation result of degradation ratio still exist, which may affect the accuracy of the acceleration model and the extrapolation value. Moreover, the conducted solution of this problem, Bayesian method, lose key information when unifying the degradation data. In this paper, a new data processing and parameter inference method based on Bayesian method is proposed to handle degradation data and solve the problems above. First, Wiener process and acceleration model is chosen; Second, the initial values of degradation model and parameters of prior and posterior distribution under each level is calculated with updating and iteration of estimation values; Third, the lifetime and reliability values are estimated on the basis of the estimation parameters; Finally, a case study is provided to demonstrate the validity of the proposed method. The results illustrate that the proposed method is quite effective and accuracy in estimating the lifetime and reliability of a product.
19 CFR 351.408 - Calculation of normal value of merchandise from nonmarket economy countries.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 19 Customs Duties 3 2010-04-01 2010-04-01 false Calculation of normal value of merchandise from nonmarket economy countries. 351.408 Section 351.408 Customs Duties INTERNATIONAL TRADE ADMINISTRATION, DEPARTMENT OF COMMERCE ANTIDUMPING AND COUNTERVAILING DUTIES Calculation of Export Price, Constructed Export Price, Fair Value, and Normal Value §...
Brand, Willi A.; Coplen, T.B.
2001-01-01
An interlaboratory comparison of forty isotope-ratio mass spectrometers of different ages from several vendors has been performed to test 2H/1H performance with hydrogen gases of three different isotopic compositions. The isotope-ratio results (unsufficiently corrected for H3+ contribution to the m/z = 3 collector, uncorrected for valve leakage in the change-over valves, etc.) expressed relative to one of these three gases covered a wide range of values: -630??? to -790??? for the second gas and -368??? to -462??? for the third gas. After normalizing the isotopic abundances of these test gases (linearly adjusting the ?? values so that the gases with the lowest and highest 2H content were identical for all laboratories), the standard deviation of the 40 measurements of the intermediate gas was a remarkably low 0.85???. It is concluded that the use of scaling factors is mandatory for providing accurate internationally comparable isotope-abundance values. Linear scaling for the isotope-ratio scales of gaseous hydrogen mass spectrometers is completely adequate. ?? Springer-Verlag 2001.
Smith, P; Endris, R; Kronvall, G; Thomas, V; Verner-Jeffreys, D; Wilhelm, C; Dalsgaard, I
2016-02-01
Epidemiological cut-off values were developed for application to antibiotic susceptibility data for Flavobacterium psychrophilum generated by standard CLSI test protocols. The MIC values for ten antibiotic agents against Flavobacterium psychrophilum were determined in two laboratories. For five antibiotics, the data sets were of sufficient quality and quantity to allow the setting of valid epidemiological cut-off values. For these agents, the cut-off values, calculated by the application of the statistically based normalized resistance interpretation method, were ≤16 mg L(-1) for erythromycin, ≤2 mg L(-1) for florfenicol, ≤0.025 mg L(-1) for oxolinic acid (OXO), ≤0.125 mg L(-1) for oxytetracycline and ≤20 (1/19) mg L(-1) for trimethoprim/sulphamethoxazole. For ampicillin and amoxicillin, the majority of putative wild-type observations were 'off scale', and therefore, statistically valid cut-off values could not be calculated. For ormetoprim/sulphadimethoxine, the data were excessively diverse and a valid cut-off could not be determined. For flumequine, the putative wild-type data were extremely skewed, and for enrofloxacin, there was inadequate separation in the MIC values for putative wild-type and non-wild-type strains. It is argued that the adoption of OXO as a class representative for the quinolone group would be a valid method of determining susceptibilities to these agents. © 2014 John Wiley & Sons Ltd.
A comparison of manual and quantitative elbow strength testing.
Shahgholi, Leili; Bengtson, Keith A; Bishop, Allen T; Shin, Alexander Y; Spinner, Robert J; Basford, Jeffrey R; Kaufman, Kenton R
2012-10-01
The aim of this study was to compare the clinical ratings of elbow strength obtained by skilled clinicians with objective strength measurement obtained through quantitative testing. A retrospective comparison of subject clinical records with quantitative strength testing results in a motion analysis laboratory was conducted. A total of 110 individuals between the ages of 8 and 65 yrs with traumatic brachial plexus injuries were identified. Patients underwent manual muscle strength testing as assessed on the 5-point British Medical Research Council Scale (5/5, normal; 0/5, absent) and quantitative elbow flexion and extension strength measurements. A total of 92 subjects had elbow flexion testing. Half of the subjects clinically assessed as having normal (5/5) elbow flexion strength on manual muscle testing exhibited less than 42% of their age-expected strength on quantitative testing. Eighty-four subjects had elbow extension strength testing. Similarly, half of those displaying normal elbow extension strength on manual muscle testing were found to have less than 62% of their age-expected values on quantitative testing. Significant differences between manual muscle testing and quantitative findings were not detected for the lesser (0-4) strength grades. Manual muscle testing, even when performed by experienced clinicians, may be more misleading than expected for subjects graded as having normal (5/5) strength. Manual muscle testing estimates for the lesser strength grades (1-4/5) seem reasonably accurate.
Experimental Studies on the Mechanical Behaviour of Rock Joints with Various Openings
NASA Astrophysics Data System (ADS)
Li, Y.; Oh, J.; Mitra, R.; Hebblewhite, B.
2016-03-01
The mechanical behaviour of rough joints is markedly affected by the degree of joint opening. A systematic experimental study was conducted to investigate the effect of the initial opening on both normal and shear deformations of rock joints. Two types of joints with triangular asperities were produced in the laboratory and subjected to compression tests and direct shear tests with different initial opening values. The results showed that opened rock joints allow much greater normal closure and result in much lower normal stiffness. A semi-logarithmic law incorporating the degree of interlocking is proposed to describe the normal deformation of opened rock joints. The proposed equation agrees well with the experimental results. Additionally, the results of direct shear tests demonstrated that shear strength and dilation are reduced because of reduced involvement of and increased damage to asperities in the process of shearing. The results indicate that constitutive models of rock joints that consider the true asperity contact area can be used to predict shear resistance along opened rock joints. Because rock masses are loosened and rock joints become open after excavation, the model suggested in this study can be incorporated into numerical procedures such as finite-element or discrete-element methods. Use of the model could then increase the accuracy and reliability of stability predictions for rock masses under excavation.
Diagnostic potential of optical coherence tomography in non-melanoma skin cancer: a clinical study
NASA Astrophysics Data System (ADS)
Mogensen, Mette; Thrane, Lars; Jørgensen, Thomas Martini; Jemec, Gregor B. E.
2007-07-01
Introduction: Non-melanoma skin cancer (NMSC) is the most prevalent cancer in the Western World. OCT has proved potential in assisting clinical diagnosis and perhaps reducing the need for biopsies in NMSC. As non-invasive treatment is increasingly used for NMSC patients with superficial lesions, the development of non-invasive diagnostic technologies is highly relevant. Methods: The aim of this cross-sectional clinical study, enrolling 100 NMSC patients and 20 healthy volunteers, is to investigate the diagnostic accuracy and applicability of OCT in NMSC diagnosis. Our OCT-system has been developed at Risoe National Laboratory, Denmark and offers ppolarization sensitive-OCT (PS-OCT) that may have additional advantaged as NMSC differ in content of birefringent collagens from normal skin. Results: Basal cell carcinomas (BCC) can in some cases be distinguished from normal skin in OCT-images, as normal skin exhibits a layered structure this layering is not present in BCC and sometimes not in actinic keratosis (AK). BCC lesions seem to be clearly less reflective than normal tissue. The predictive value of OCT in NMSC will be presented from a clinical point of view. Discussion: The earlier a skin cancer is diagnosed, the better the prognosis. Estimation of diagnostic accuracy and abilities of OCT in clinical studies of skin cancer patients is essential to establish the role and future set-ups for diagnostic OCT-systems.
National and international veterinary reference laboratories for infectious diseases.
Edwards, S; Alexander, D
1998-08-01
Reference laboratories play an increasingly important role in the harmonisation of laboratory diagnostic tests and the standardisation of veterinary vaccines. This is particularly important in building confidence between international trading partners. The authors review aspects of the organisation, designation and support of reference laboratories for infectious diseases of animals and discuss the principal activities which such laboratories would normally perform. These activities include advice and consultancy, publications and communication, training, research, disease surveillance, maintenance of culture collections, evaluation of reference methods, preparation of reference materials and organisation of inter-laboratory comparisons.
NASA Astrophysics Data System (ADS)
Dolan, E. M.; Perdrial, J. N.; Vazquez, A.; Hernández, S.; Chorover, J.
2010-12-01
Elizabeth Dolan1,2, Julia Perdrial3, Angélica Vázquez-Ortega3, Selene Hernández-Ruiz3, Jon Chorover3 1Deptartment of Soil, Environmental, and Atmospheric Science, University of Missouri. 2Biosphere 2, University of Arizona. 3Deptartment of Soil, Water, and Environmental Science, University of Arizona. Abstract: The behavior of dissolved organic matter (DOM) in soil is important to many biogeochemical processes. Extraction methods to obtain DOM from the unsaturated zone remain a current focus of research as different methods can influence the type and concentration of DOM obtained. Thus, the present comparison study involves three methods for soil solution sampling to assess their impact on DOM quantity and quality: 1) aqueous soil extracts, 2) solution yielded from laboratory installed suction cup samplers and 3) solutions from field installed suction cup samplers. All samples were analyzed for dissolved organic carbon and total nitrogen concentrations. Moreover, DOM quality was analyzed using fluorescence, UV-Vis and FTIR spectroscopies. Results indicate higher DOC values for laboratory extracted DOM: 20 mg/L for aqueous soil extracts and 31 mg/L for lab installed samplers compared to 12 mg/L for field installed samplers. Large variations in C/N ratios were also observed ranging from 1.5 in laboratory extracted DOM to 11 in field samples. Fluorescence excitation-emission matrices of DOM solutions obtained for the laboratory extraction methods showed higher intensities in regions typical for fulvic and humic acid-like materials relative to those extracted in the field. Similarly, the molar absorptivity calculated from DOC concentration normalization of UV-Vis absorbance of the laboratory-derived solutions was significantly higher as well, indicating greater aromaticity. The observed differences can be attributed to soil disturbance associated with obtaining laboratory derived solution samples. Our results indicate that laboratory extraction methods are not comparable to in-situ field soil solution extraction in terms of DOM.
Anatomical Variation of the Tarsus in Common Inbred Mouse Strains.
Richbourg, Heather A; Martin, Matthew J; Schachner, Emma R; McNulty, Margaret A
2017-03-01
Rodent models are used for a variety of orthopedic research applications; however, anatomy references include mostly artistic representations. Advanced imaging techniques, including micro-computed tomography (microCT), can provide more accurate representations of subtle anatomical characteristics. A recent microCT atlas of laboratory mouse (Mus musculus) anatomy depicts the central and tarsal bone III (T3) as a single bone, differing from previous references. Fusion of tarsal bones is generally characterized as pathological secondary to mutations associated with growth factors, and normal variation has not been documented in the mouse tarsus. Therefore, it is unclear if this fusion is a normal or a pathological characteristic. The aim of this study is to characterize the tarsus of the laboratory mouse and compare it to the rat and selected outgroup species (i.e., white-footed mouse) via microCT and histology to determine if the central and T3 are separate or fused into a single bone. Laboratory mice (C57/Bl6 [n = 17] and BalbC [n = 2]) and rats (n = 5) were scanned with microCT. A representative laboratory mouse from each strain was evaluated histologically via serial sagittal sections through the mid-tarsus. General pedal anatomy was similar between all species; however, the central and T3 bones were fused in all laboratory mice but not the rat or white-footed mouse. A band of hyaline cartilage was identified within the fused bone of the laboratory mice. We conclude that the fusion found is a normal characteristic in laboratory mice, but timing of the fusion remains ambiguous. Anat Rec, 300:450-459, 2017. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.
Tientadakul, Panutsaya; Opartkiattikul, Nisarat; Wongtiraporn, Wanida
2009-01-01
In Thailand until 2005 there had been no external quality assessment scheme at the national level for blood coagulation tests. Only a few laboratories had an external quality assessment for these tests. In the year 2005, the Thailand National External Quality Assessment Scheme for Blood Coagulation was founded. To describe the establishment of the Thailand National External Quality Assessment Scheme for Blood Coagulation (including problems encountered and solutions), its progression and expansion, and the improvement of coagulation laboratory practice in Thailand during 2 trial surveys and 4 formal surveys conducted in the first 1 1/2 years. Between 2005 and 2006, the external quality assessment samples for prothrombin time/international normalized ratio and activated partial thromboplastin time were distributed to the participants as well as the instructions and suggestions for the improvement of laboratory practice. From the data collected, the all-method coefficient of variation of the international normalized ratio and activated partial thromboplastin time was calculated for each survey. The number of participants increased during the first 1 1/2 years that the surveys were conducted, from 109 to 127. Survey data demonstrate an improvement in response rate and an increase in the number of laboratories that determine their own reference ranges and repeat this for every change of reagent lot, using the appropriate anticoagulant. The increased precision of tests is indicated by the decrease of the all-method coefficient of variation of the international normalized ratio and activated partial thromboplastin time. Examples of individual laboratory improvement through feedback are also described. The improvement of coagulation laboratory practice both through the instructions provided and liaison with participants was observed during the course of this scheme.
Dynamic Divisive Normalization Predicts Time-Varying Value Coding in Decision-Related Circuits
LoFaro, Thomas; Webb, Ryan; Glimcher, Paul W.
2014-01-01
Normalization is a widespread neural computation, mediating divisive gain control in sensory processing and implementing a context-dependent value code in decision-related frontal and parietal cortices. Although decision-making is a dynamic process with complex temporal characteristics, most models of normalization are time-independent and little is known about the dynamic interaction of normalization and choice. Here, we show that a simple differential equation model of normalization explains the characteristic phasic-sustained pattern of cortical decision activity and predicts specific normalization dynamics: value coding during initial transients, time-varying value modulation, and delayed onset of contextual information. Empirically, we observe these predicted dynamics in saccade-related neurons in monkey lateral intraparietal cortex. Furthermore, such models naturally incorporate a time-weighted average of past activity, implementing an intrinsic reference-dependence in value coding. These results suggest that a single network mechanism can explain both transient and sustained decision activity, emphasizing the importance of a dynamic view of normalization in neural coding. PMID:25429145
Comparison of diffusion-weighted MRI acquisition techniques for normal pancreas at 3.0 Tesla.
Yao, Xiu-Zhong; Kuang, Tiantao; Wu, Li; Feng, Hao; Liu, Hao; Cheng, Wei-Zhong; Rao, Sheng-Xiang; Wang, He; Zeng, Meng-Su
2014-01-01
We aimed to optimize diffusion-weighted imaging (DWI) acquisitions for normal pancreas at 3.0 Tesla. Thirty healthy volunteers were examined using four DWI acquisition techniques with b values of 0 and 600 s/mm2 at 3.0 Tesla, including breath-hold DWI, respiratory-triggered DWI, respiratory-triggered DWI with inversion recovery (IR), and free-breathing DWI with IR. Artifacts, signal-to-noise ratio (SNR) and apparent diffusion coefficient (ADC) of normal pancreas were statistically evaluated among different DWI acquisitions. Statistical differences were noticed in artifacts, SNR, and ADC values of normal pancreas among different DWI acquisitions by ANOVA (P <0.001). Normal pancreas imaging had the lowest artifact in respiratory-triggered DWI with IR, the highest SNR in respiratory-triggered DWI, and the highest ADC value in free-breathing DWI with IR. The head, body, and tail of normal pancreas had statistically different ADC values on each DWI acquisition by ANOVA (P < 0.05). The highest image quality for normal pancreas was obtained using respiratory-triggered DWI with IR. Normal pancreas displayed inhomogeneous ADC values along the head, body, and tail structures.
28 CFR Appendix A to Part 79 - FVC and FEV-1 Lower Limits of Normal Values
Code of Federal Regulations, 2011 CFR
2011-07-01
... 28 Judicial Administration 2 2011-07-01 2011-07-01 false FVC and FEV-1 Lower Limits of Normal... RADIATION EXPOSURE COMPENSATION ACT Pt. 79, App. A Appendix A to Part 79—FVC and FEV-1 Lower Limits of Normal Values Table 1—Caucasian Males FVC Lower Limit of Normal Values, Hankinson, et al. (1999...
Cell Injury and Repair Resulting from Sleep Loss and Sleep Recovery in Laboratory Rats
Everson, Carol A.; Henchen, Christopher J.; Szabo, Aniko; Hogg, Neil
2014-01-01
Study Objectives: Increased cell injury would provide the type of change in constitution that would underlie sleep disruption as a risk factor for multiple diseases. The current study was undertaken to investigate cell injury and altered cell fate as consequences of sleep deprivation, which were predicted from systemic clues. Design: Partial (35% sleep reduction) and total sleep deprivation were produced in rats for 10 days, which was tolerated and without overtly deteriorated health. Recovery rats were similarly sleep deprived for 10 days, then allowed undisturbed sleep for 2 days. The plasma, liver, lung, intestine, heart, and spleen were analyzed and compared to control values for damage to DNA, proteins, and lipids; apoptotic cell signaling and death; cell proliferation; and concentrations of glutathione peroxidase and catalase. Measurements and Results: Oxidative DNA damage in totally sleep deprived rats was 139% of control values, with organ-specific effects in the liver (247%), lung (166%), and small intestine (145%). Overall and organ-specific DNA damage was also increased in partially sleep deprived rats. In the intestinal epithelium, total sleep deprivation resulted in 5.3-fold increases in dying cells and 1.5-fold increases in proliferating cells, compared with control. Two days of recovery sleep restored the balance between DNA damage and repair, and resulted in normal or below-normal metabolic burdens and oxidative damage. Conclusions: These findings provide physical evidence that sleep loss causes cell damage, and in a manner expected to predispose to replication errors and metabolic abnormalities; thereby providing linkage between sleep loss and disease risk observed in epidemiological findings. Properties of recovery sleep include biochemical and molecular events that restore balance and decrease cell injury. Citation: Everson CA, Henchen CJ, Szabo A, Hogg N. Cell injury and repair resulting from sleep loss and sleep recovery in laboratory rats. SLEEP 2014;37(12):1929-1940. PMID:25325492
Anatomy of a value proposition for laboratory medicine.
Price, Christopher P; St John, Andrew
2014-09-25
Value is now becoming a key driver in the ongoing development of healthcare delivery; key facets include the identification of what is valuable and how that value can be identified, leveraged, and delivered. The concept of a value proposition is widely used in business but can be used in healthcare as a statement of the benefits, costs and value that an organization can deliver to its customers. The foundation of this statement in laboratory medicine is evidence of clinical and cost effectiveness, not only for the patient, but also for other stakeholders involved in the delivery of healthcare, e.g., the carer, service provider, commissioner, purchaser, and the supplier of the test or device, as well as society as a whole. However the value of any laboratory medicine investigation is only achieved if the output (the test result(s)), is acted upon by the initiator of the investigation. Laboratory medicine is one part of a complex intervention, and so the value proposition should encompass the breadth of that intervention - from addressing the unmet need through the generation of clinical, operational and economic outcomes. A value proposition in laboratory medicine is central to successful innovation and quality improvement in healthcare. Copyright © 2014 Elsevier B.V. All rights reserved.
Ong Tan, Kendrich Graemer
2017-09-01
The present study aimed to investigate the contact quotient (CQ) values of breathy, normal, and pressed phonation types in four different sections of the female singing range. Electroglottography (EGG) and acoustic signals were recorded from 10 female singing teachers. Five vowels were sung for 1-3 seconds each, in three phonation types-normal, breathy, and pressed, in four pitches representing registration change points in the singing range. CQ values were automatically generated from the EGG signal using VoceVista at 35% threshold level. Sound pressure levels were checked in Praat. Unianova and correlations were performed using an SPSS program. CQ values of female participants in the study yielded ranges of 0.25-0.62 in normal and 0.34-0.73 in pressed. Normal and pressed CQ differed significantly from each other at P < 0.00. Breathy samples were not viable for analysis. A concentration of CQ values from 0.5 to 0.6 of both pressed low and pressed break samples was noted, but CQ values across the pitch range showed no significant trend. Normal and pressed phonation CQ values beyond the speaking pitch varied among the subjects. Pressed phonation CQ values were mostly higher, but the values were only relative to the corresponding normal phonation on the same pitch. Other measurements may be more suitable for measuring vocal fold impact stress in higher frequencies, thus, distinguishing normal from pressed singing. Copyright © 2017 The Voice Foundation. Published by Elsevier Inc. All rights reserved.
Leveraging the real value of laboratory medicine with the value proposition.
Price, Christopher P; John, Andrew St; Christenson, Robert; Scharnhorst, Volker; Oellerich, Michael; Jones, Patricia; Morris, Howard A
2016-11-01
Improving quality and patient safety, containing costs and delivering value-for-money are the key drivers of change in the delivery of healthcare and have stimulated a shift from an activity-based service to a service based on patient-outcomes. The delivery of an outcomes-based healthcare agenda requires that the real value of laboratory medicine to all stakeholders be understood, effectively defined and communicated. The value proposition of any product or service is the link between the provider and the needs of the customer describing the utility of the product or service in terms of benefit to the customer. The framework of a value proposition for laboratory medicine provides the core business case that drives key activities in the evolution and maintenance of high quality healthcare from research through to adoption and quality improvement in an established service. The framework of a value proposition for laboratory medicine is described. The content is endorsed by IFCC and WASPaLM. Copyright © 2016 Elsevier B.V. All rights reserved.
Lin, Shu-Wen; Kang, Wen-Yi; Lin, Dong-Tsamn; Lee, James; Wu, Fe-Lin; Chen, Chuen-Liang; Tseng, Yufeng J
2014-01-01
Computerized alert and reminder systems have been widely accepted and applied to various patient care settings, with increasing numbers of clinical laboratories communicating critical laboratory test values to professionals via either manual notification or automated alerting systems/computerized reminders. Warfarin, an oral anticoagulant, exhibits narrow therapeutic range between treatment response and adverse events. It requires close monitoring of prothrombin time (PT)/international normalized ratio (INR) to ensure patient safety. This study was aimed to evaluate clinical outcomes of patients on warfarin therapy following implementation of a Personal Handy-phone System-based (PHS) alert system capable of generating and delivering text messages to communicate critical PT/INR laboratory results to practitioners' mobile phones in a large tertiary teaching hospital. A retrospective analysis was performed comparing patient clinical outcomes and physician prescribing behavior following conversion from a manual laboratory result alert system to an automated system. Clinical outcomes and practitioner responses to both alert systems were compared. Complications to warfarin therapy, warfarin utilization, and PT/INR results were evaluated for both systems, as well as clinician time to read alert messages, time to warfarin therapy modification, and monitoring frequency. No significant differences were detected in major hemorrhage and thromboembolism, warfarin prescribing patterns, PT/INR results, warfarin therapy modification, or monitoring frequency following implementation of the PHS text alert system. In both study periods, approximately 80% of critical results led to warfarin discontinuation or dose reduction. Senior physicians' follow-up response time to critical results was significantly decreased in the PHS alert study period (46.3% responded within 1 day) compared to the manual notification study period (24.7%; P = 0.015). No difference in follow-up response time was detected for junior physicians. Implementation of an automated PHS-based text alert system did not adversely impact clinical or safety outcomes of patients on warfarin therapy. Approximately 80% immediate recognition of text alerts was achieved. The potential benefits of an automated PHS alert for senior physicians were demonstrated.
19 CFR 351.408 - Calculation of normal value of merchandise from nonmarket economy countries.
Code of Federal Regulations, 2013 CFR
2013-04-01
... nonmarket economy countries. 351.408 Section 351.408 Customs Duties INTERNATIONAL TRADE ADMINISTRATION... economy countries. (a) Introduction. In identifying dumping from a nonmarket economy country, the Secretary normally will calculate normal value by valuing the nonmarket economy producers' factors of...
19 CFR 351.408 - Calculation of normal value of merchandise from nonmarket economy countries.
Code of Federal Regulations, 2011 CFR
2011-04-01
... nonmarket economy countries. 351.408 Section 351.408 Customs Duties INTERNATIONAL TRADE ADMINISTRATION... economy countries. (a) Introduction. In identifying dumping from a nonmarket economy country, the Secretary normally will calculate normal value by valuing the nonmarket economy producers' factors of...
19 CFR 351.408 - Calculation of normal value of merchandise from nonmarket economy countries.
Code of Federal Regulations, 2012 CFR
2012-04-01
... nonmarket economy countries. 351.408 Section 351.408 Customs Duties INTERNATIONAL TRADE ADMINISTRATION... economy countries. (a) Introduction. In identifying dumping from a nonmarket economy country, the Secretary normally will calculate normal value by valuing the nonmarket economy producers' factors of...
19 CFR 351.408 - Calculation of normal value of merchandise from nonmarket economy countries.
Code of Federal Regulations, 2014 CFR
2014-04-01
... nonmarket economy countries. 351.408 Section 351.408 Customs Duties INTERNATIONAL TRADE ADMINISTRATION... economy countries. (a) Introduction. In identifying dumping from a nonmarket economy country, the Secretary normally will calculate normal value by valuing the nonmarket economy producers' factors of...
Puberty, statural growth, and growth hormone release in children with cerebral palsy
Kuperminc, Michelle N.; Gurka, Matthew J.; Houlihan, Christine M.; Henderson, Richard C.; Roemmich, James N.; Rogol, Alan D.
2010-01-01
Objective Children with cerebral palsy (CP) are smaller than normally growing children.. The association between the growth hormone (GH) axis and growth in children with CP during puberty is unknown. We compared growth and markers of the GH axis in pre-pubertal and pubertal children with moderate to severe CP and without CP over a three-year period. Study design Twenty children with CP, ages 6–18, Gross Motor Function Classification System levels III–V, were compared to a group of sixty-three normally growing children of similar age. Anthropometry, Tanner stage, bone age, and laboratory analyses were performed every six months for three years. Laboratory values included spontaneous overnight GH release, fasting IGF-1 and IGFBP-3. Repeated measures models were used to evaluate interactions among Tanner stage and group (children with CP vs. reference children), taking into account gender, age, and nutritional status. Results Children with CP grew more slowly than those without CP at all Tanner stages (p<0.01). Patterns of IGF-1 and GH secretion in children with CP were similar to those of the reference group; however, the concentrations of IGF-1 (p<0.01) and GH (p<0.01) were lower in girls with CP, with a similar trend for boys (p=0.10 and 0.14, respectively). Conclusions Diminished circulating IGF-1 and GH concentrations may explain the differences in growth between the two groups. PMID:20216931
[A novel method for targeting and characterizing healthy older people].
Carrasco, Marcela; Martínez, Gabriel; Foradori, Arnaldo; Hoyl, Trinidad; Valenzuela, Eduardo; Quiroga, Teresa; Gac, Homero; Ihle, Sofia; Marin, Pedro Paulo
2010-09-01
there is no established definition of healthy aging in clinical practice, although it is a World Health Organization goal. to develop a clinical protocol to identify healthy older people living in the community and study their clinical, laboratory and functional characteristics. healthy people aged 60 years or older, were invited to participate in the study, by newspapers and radio, if they selfperceived as healthy, lived in the community, were functionally independent and had low disease burden. Potential participants were initially screened by telephone, and those who met the inclusion criteria were included. They had a comprehensive geriatric assessment which included clinical, anthropometric, laboratory and functional assessments. of 384 people who answered the call, 83 subjects aged 60 to 98 years (57% women) met the inclusion criteria of healthy older people. Seventy eight percent did not consume any medication, 100% were able to perform physical activities that required at least three metabolic equivalents (Mets). Basic laboratory showed that approximately 90% of subjects had normal values, using standard benchmarks established for an adult population. the protocol used in this work was able to identify healthy older people with low disease burden and good functionality. It also validated history and comprehensive geriatric assessment as reliable instruments to identify these subjects.
Manor, Brad; Yu, Wanting; Zhu, Hao; Harrison, Rachel; Lo, On-Yee; Lipsitz, Lewis; Travison, Thomas; Pascual-Leone, Alvaro; Zhou, Junhong
2018-01-30
Walking is a complex cognitive motor task that is commonly completed while performing another task such as talking or making decisions. Gait assessments performed under normal and "dual-task" walking conditions thus provide important insights into health. Such assessments, however, are limited primarily to laboratory-based settings. The objective of our study was to create and test a smartphone-based assessment of normal and dual-task walking for use in nonlaboratory settings. We created an iPhone app that used the phone's motion sensors to record movements during walking under normal conditions and while performing a serial-subtraction dual task, with the phone placed in the user's pants pocket. The app provided the user with multimedia instructions before and during the assessment. Acquired data were automatically uploaded to a cloud-based server for offline analyses. A total of 14 healthy adults completed 2 laboratory visits separated by 1 week. On each visit, they used the app to complete three 45-second trials each of normal and dual-task walking. Kinematic data were collected with the app and a gold-standard-instrumented GAITRite mat. Participants also used the app to complete normal and dual-task walking trials within their homes on 3 separate days. Within laboratory-based trials, GAITRite-derived heel strikes and toe-offs of the phone-side leg aligned with smartphone acceleration extrema, following filtering and rotation to the earth coordinate system. We derived stride times-a clinically meaningful metric of locomotor control-from GAITRite and app data, for all strides occurring over the GAITRite mat. We calculated stride times and the dual-task cost to the average stride time (ie, percentage change from normal to dual-task conditions) from both measurement devices. We calculated similar metrics from home-based app data. For these trials, periods of potential turning were identified via custom-developed algorithms and omitted from stride-time analyses. Across all detected strides in the laboratory, stride times derived from the app and GAITRite mat were highly correlated (P<.001, r 2 =.98). These correlations were independent of walking condition and pocket tightness. App- and GAITRite-derived stride-time dual-task costs were also highly correlated (P<.001, r 2 =.95). The error of app-derived stride times (mean 16.9, SD 9.0 ms) was unaffected by the magnitude of stride time, walking condition, or pocket tightness. For both normal and dual-task trials, average stride times derived from app walking trials demonstrated excellent test-retest reliability within and between both laboratory and home-based assessments (intraclass correlation coefficient range .82-.94). The iPhone app we created enabled valid and reliable assessment of stride timing-with the smartphone in the pocket-during both normal and dual-task walking and within both laboratory and nonlaboratory environments. Additional work is warranted to expand the functionality of this tool to older adults and other patient populations. ©Brad Manor, Wanting Yu, Hao Zhu, Rachel Harrison, On-Yee Lo, Lewis Lipsitz, Thomas Travison, Alvaro Pascual-Leone, Junhong Zhou. Originally published in JMIR Mhealth and Uhealth (http://mhealth.jmir.org), 30.01.2018.
Yu, Wanting; Zhu, Hao; Harrison, Rachel; Lo, On-Yee; Lipsitz, Lewis; Travison, Thomas; Pascual-Leone, Alvaro; Zhou, Junhong
2018-01-01
Background Walking is a complex cognitive motor task that is commonly completed while performing another task such as talking or making decisions. Gait assessments performed under normal and “dual-task” walking conditions thus provide important insights into health. Such assessments, however, are limited primarily to laboratory-based settings. Objective The objective of our study was to create and test a smartphone-based assessment of normal and dual-task walking for use in nonlaboratory settings. Methods We created an iPhone app that used the phone’s motion sensors to record movements during walking under normal conditions and while performing a serial-subtraction dual task, with the phone placed in the user’s pants pocket. The app provided the user with multimedia instructions before and during the assessment. Acquired data were automatically uploaded to a cloud-based server for offline analyses. A total of 14 healthy adults completed 2 laboratory visits separated by 1 week. On each visit, they used the app to complete three 45-second trials each of normal and dual-task walking. Kinematic data were collected with the app and a gold-standard–instrumented GAITRite mat. Participants also used the app to complete normal and dual-task walking trials within their homes on 3 separate days. Within laboratory-based trials, GAITRite-derived heel strikes and toe-offs of the phone-side leg aligned with smartphone acceleration extrema, following filtering and rotation to the earth coordinate system. We derived stride times—a clinically meaningful metric of locomotor control—from GAITRite and app data, for all strides occurring over the GAITRite mat. We calculated stride times and the dual-task cost to the average stride time (ie, percentage change from normal to dual-task conditions) from both measurement devices. We calculated similar metrics from home-based app data. For these trials, periods of potential turning were identified via custom-developed algorithms and omitted from stride-time analyses. Results Across all detected strides in the laboratory, stride times derived from the app and GAITRite mat were highly correlated (P<.001, r2=.98). These correlations were independent of walking condition and pocket tightness. App- and GAITRite-derived stride-time dual-task costs were also highly correlated (P<.001, r2=.95). The error of app-derived stride times (mean 16.9, SD 9.0 ms) was unaffected by the magnitude of stride time, walking condition, or pocket tightness. For both normal and dual-task trials, average stride times derived from app walking trials demonstrated excellent test-retest reliability within and between both laboratory and home-based assessments (intraclass correlation coefficient range .82-.94). Conclusions The iPhone app we created enabled valid and reliable assessment of stride timing—with the smartphone in the pocket—during both normal and dual-task walking and within both laboratory and nonlaboratory environments. Additional work is warranted to expand the functionality of this tool to older adults and other patient populations. PMID:29382625
Kul, Melahat; Erden, Ayşe; Düşünceli Atman, Ebru
2017-04-01
To assess the diagnostic value of dynamic T 1 weighted (T1w) gadolinium ethoxybenzyl diethylenetriamine penta-acetic acid (Gd-EOB-DTPA)-enhanced MR cholangiography (MRC) for the detection of active bile leaks. A total of 28 patients with suspected biliary leakage who underwent routine T 2 weighted (T2w) MRC and T1w GD-EOB-DTPA-enhanced MRC at our institution from February 2013 to June 2016 were included in this study. The image sets were retrospectively analyzed in consensus by three radiologists. T1w Gd-EOB-DTPA-enhanced MRC findings were correlated with clinical data, follow-up examinations and findings of invasive/surgical procedures. Patients with positive bile leak findings in Gd-EOB-DTPA-enhanced MRC were divided into hepatobiliary phase (HBP) (20-30 min) and delayed phase (DP) (60-390 min) group according to elapsed time between Gd-EOB-DTPA injection and initial bile leak findings in MRC images. These groups were compared in terms of laboratory test results (total bilirubin, liver enzymes) and the presence of bile duct dilatation in T2w MRC images. In each patient, visualization of bile ducts was sufficient in the HBP. The accuracy, sensitivity and specificity of dynamic Gd-EOB-DTPA-enhanced T1w MRC in the detection of biliary leaks were 92.9%, 90.5% and 100%, respectively (p < 0.001). 19 of 28 patients had bile leak findings in T1w Gd-EOB-DTPA-enhanced MRC [HBP group: N = 7 (36.8%), DP group: N = 12 (63.2%)]. There was no statistically significant difference in terms of laboratory test results and the presence of bile duct dilatation between HBP and DP group (p > 0.05). Three patients, each of them in DP group, showed normal laboratory test results and bile duct diameters. Dynamic T1w Gd-EOB-DTPA-enhanced MRC is a useful non-invasive diagnostic tool to detect bile leak. Advances in knowledge: Prolonged DP imaging may be required for bile leak detection even if visualization of biliary tree is sufficient in HBP and liver function tests, total bilirubin levels and bile duct diameters are normal.
NASA Astrophysics Data System (ADS)
Sulpizio, R.; Castioni, D.; Rodriguez-Sedano, L. A.; Sarocchi, D.; Lucchi, F.
2016-11-01
Laboratory experiments on granular flows using natural material were carried out in order to investigate the behaviour of granular flows passing over a break in slope. Sensors in the depositional area recorded the flow kinematics, while video footage permitted reconstruction of the deposit formation, which allowed investigation of the deposit shape as a function of the change in slope. We defined the slope-angle ratio as the proportion between slope angle in the depositional area and that of the channel. When the granular flow encounters the break in slope part of the flow front forms a bouncing clast zone due to elastic impact with the expansion box floor. During this process, part of the kinetic energy of the dense granular flow is transferred to elutriating fine ash, which subsequently forms turbulent ash cloud accompanying the granular flow until it comes to rest. Morphometric analysis of the deposits shows that they are all elliptical, with an almost constant minor axis and a variable major axis. The almost constant value of the minor axis relates to the spreading angle of flow at the end of the channel, which resembles the basal friction angle of the material. The variation of the major axis is interpreted to relate to the effect of competing inertial and frictional forces. This effect also reflects the partitioning of centripetal and tangential velocities, which changes as the flow passes over the break in slope. After normalization, morphometric data provided empirical relationships that highlight the dependence of runout from the product of slope-angle ratio and the difference in height between granular material release and deposit. The empirical relationships were tested against the runouts of hot avalanches formed during the 1944 ad eruption at Vesuvius, with differences among actual and calculated values are between 1.7 and 15 %. Velocity measurements of laboratory granular flows record deceleration paths at different breaks in slope. When normalized, the velocity data show third-order polynomial fit, highlighting a complex behaviour involving interplay between inertial and frictional forces. The theoretical velocity decays were tested against the data published for volcaniclastic debris flows of the 5-6 May 1998 event in the Sarno area. The comparison is very good for non-channelized debris flows, with significant differences between actual and calculated velocities for the channelized debris flows.
Fooken, Jonas
2017-03-10
The present study investigates the external validity of emotional value measured in economic laboratory experiments by using a physiological indicator of stress, heart rate variability (HRV). While there is ample evidence supporting the external validity of economic experiments, there is little evidence comparing the magnitude of internal levels of emotional stress during decision making with external stress. The current study addresses this gap by comparing the magnitudes of decision stress experienced in the laboratory with the stress from outside the laboratory. To quantify a large change in HRV, measures observed in the laboratory during decision-making are compared to the difference between HRV during a university exam and other mental activity for the same individuals in and outside of the laboratory. The results outside the laboratory inform about the relevance of laboratory findings in terms of their relative magnitude. Results show that psychologically induced HRV changes observed in the laboratory, particularly in connection with social preferences, correspond to large effects outside. This underscores the external validity of laboratory findings and shows the magnitude of emotional value connected to pro-social economic decisions in the laboratory.
Satyagraha, Ari W.; Sadhewa, Arkasha; Elvira, Rosalie; Elyazar, Iqbal; Feriandika, Denny; Antonjaya, Ungke; Oyong, Damian; Subekti, Decy; Rozi, Ismail E.; Domingo, Gonzalo J.; Harahap, Alida R.; Baird, J. Kevin
2016-01-01
Background Patients infected by Plasmodium vivax or Plasmodium ovale suffer repeated clinical attacks without primaquine therapy against latent stages in liver. Primaquine causes seriously threatening acute hemolytic anemia in patients having inherited glucose-6-phosphate dehydrogenase (G6PD) deficiency. Access to safe primaquine therapy hinges upon the ability to confirm G6PD normal status. CareStart G6PD, a qualitative G6PD rapid diagnostic test (G6PD RDT) intended for use at point-of-care in impoverished rural settings where most malaria patients live, was evaluated. Methodology/Principal Findings This device and the standard qualitative fluorescent spot test (FST) were each compared against the quantitative spectrophotometric assay for G6PD activity as the diagnostic gold standard. The assessment occurred at meso-endemic Panenggo Ede in western Sumba Island in eastern Indonesia, where 610 residents provided venous blood. The G6PD RDT and FST qualitative assessments were performed in the field, whereas the quantitative assay was performed in a research laboratory at Jakarta. The median G6PD activity ≥5 U/gHb was 9.7 U/gHb and was considered 100% of normal activity. The prevalence of G6PD deficiency by quantitative assessment (<5 U/gHb) was 7.2%. Applying 30% of normal G6PD activity as the cut-off for qualitative testing, the sensitivity, specificity, positive predictive value, and negative predictive value for G6PD RDT versus FST among males were as follows: 100%, 98.7%, 89%, and 100% versus 91.7%, 92%, 55%, and 99%; P = 0.49, 0.001, 0.004, and 0.24, respectively. These values among females were: 83%, 92.7%, 17%, and 99.7% versus 100%, 92%, 18%, and 100%; P = 1.0, 0.89, 1.0 and 1.0, respectively. Conclusions/Significance The overall performance of G6PD RDT, especially 100% negative predictive value, demonstrates suitable safety for G6PD screening prior to administering hemolytic drugs like primaquine and many others. Relatively poor diagnostic performance among females due to mosaic G6PD phenotype is an inherent limitation of any current practical screening methodology. PMID:26894297
Satyagraha, Ari W; Sadhewa, Arkasha; Elvira, Rosalie; Elyazar, Iqbal; Feriandika, Denny; Antonjaya, Ungke; Oyong, Damian; Subekti, Decy; Rozi, Ismail E; Domingo, Gonzalo J; Harahap, Alida R; Baird, J Kevin
2016-02-01
Patients infected by Plasmodium vivax or Plasmodium ovale suffer repeated clinical attacks without primaquine therapy against latent stages in liver. Primaquine causes seriously threatening acute hemolytic anemia in patients having inherited glucose-6-phosphate dehydrogenase (G6PD) deficiency. Access to safe primaquine therapy hinges upon the ability to confirm G6PD normal status. CareStart G6PD, a qualitative G6PD rapid diagnostic test (G6PD RDT) intended for use at point-of-care in impoverished rural settings where most malaria patients live, was evaluated. This device and the standard qualitative fluorescent spot test (FST) were each compared against the quantitative spectrophotometric assay for G6PD activity as the diagnostic gold standard. The assessment occurred at meso-endemic Panenggo Ede in western Sumba Island in eastern Indonesia, where 610 residents provided venous blood. The G6PD RDT and FST qualitative assessments were performed in the field, whereas the quantitative assay was performed in a research laboratory at Jakarta. The median G6PD activity ≥ 5 U/gHb was 9.7 U/gHb and was considered 100% of normal activity. The prevalence of G6PD deficiency by quantitative assessment (<5 U/gHb) was 7.2%. Applying 30% of normal G6PD activity as the cut-off for qualitative testing, the sensitivity, specificity, positive predictive value, and negative predictive value for G6PD RDT versus FST among males were as follows: 100%, 98.7%, 89%, and 100% versus 91.7%, 92%, 55%, and 99%; P = 0.49, 0.001, 0.004, and 0.24, respectively. These values among females were: 83%, 92.7%, 17%, and 99.7% versus 100%, 92%, 18%, and 100%; P = 1.0, 0.89, 1.0 and 1.0, respectively. The overall performance of G6PD RDT, especially 100% negative predictive value, demonstrates suitable safety for G6PD screening prior to administering hemolytic drugs like primaquine and many others. Relatively poor diagnostic performance among females due to mosaic G6PD phenotype is an inherent limitation of any current practical screening methodology.
A new concept for stainless steels ranking upon the resistance to cavitation erosion
NASA Astrophysics Data System (ADS)
Bordeasu, I.; Popoviciu, M. O.; Salcianu, L. C.; Ghera, C.; Micu, L. M.; Badarau, R.; Iosif, A.; Pirvulescu, L. D.; Podoleanu, C. E.
2017-01-01
In present, the ranking of materials as their resistance to cavitation erosion is obtained by using laboratory tests finalized with the characteristic curves mean depth erosion against time MDE(t) and mean depth erosion rate against time MDER(t). In some previous papers, Bordeasu and co-workers give procedures to establish exponential equation representing the curves, with minimum scatter of the experimental obtained results. For a given material, both exponential equations MDE(t) and MDER(t) have the same values for the parameters of scale and for the shape one. For the ranking of materials is sometimes important to establish single figure. Till now in Timisoara Polytechnic University Cavitation Laboratory were used three such numbers: the stable value of the curve MDER(t), the resistance to cavitation erosion (Rcav ≡ 1/MDERstable) and the normalized cavitation resistance Rns which is the rate between vs = MDERstable for the analyzed material and vse= MDERse the mean depth erosion rate for the steel OH12NDL (Rns = vs/vse ). OH12NDL is a material used for manufacturing the blades of numerous Kaplan turbines in Romania for which both cavitation erosion laboratory tests and field measurements of cavitation erosions are available. In the present paper we recommend a new method for ranking the materials upon cavitation erosion resistance. This method uses the scale and shape parameters of the exponential equations which represents the characteristic cavitation erosion curves. Till now the method was applied only for stainless steels. The experimental results show that the scale parameter represents an excellent method for ranking the stainless steels. In the future this kind of ranking will be tested also for other materials especially for bronzes used for manufacturing ship propellers.
Miri-Dashe, Timzing; Osawe, Sophia; Tokdung, Monday; Daniel, Monday Tokdung Nenbammun; Daniel, Nenbammun; Choji, Rahila Pam; Mamman, Ille; Deme, Kurt; Damulak, Dapus; Abimiku, Alash'le
2014-01-01
Interpretation of laboratory test results with appropriate diagnostic accuracy requires reference or cutoff values. This study is a comprehensive determination of reference values for hematology and clinical chemistry in apparently healthy voluntary non-remunerated blood donors and pregnant women. Consented clients were clinically screened and counseled before testing for HIV, Hepatitis B, Hepatitis C and Syphilis. Standard national blood donors' questionnaire was administered to consented blood donors. Blood from qualified volunteers was used for measurement of complete hematology and chemistry parameters. Blood samples were analyzed from a total of 383 participants, 124 (32.4%) males, 125 (32.6%) non-pregnant females and 134 pregnant females (35.2%) with a mean age of 31 years. Our results showed that the red blood cells count (RBC), Hemoglobin (HB) and Hematocrit (HCT) had significant gender difference (p = 0.000) but not for total white blood count (p>0.05) which was only significantly higher in pregnant verses non-pregnant women (p = 0.000). Hemoglobin and Hematocrit values were lower in pregnancy (P = 0.000). Platelets were significantly higher in females than men (p = 0.001) but lower in pregnant women (p = .001) with marked difference in gestational period. For clinical chemistry parameters, there was no significant difference for sodium, potassium and chloride (p>0.05) but gender difference exists for Bicarbonate (HCO3), Urea nitrogen, Creatinine as well as the lipids (p<0.05). Total bilirubin was significantly higher in males than females (p = 0.000). Significant differences exist for all chemistry parameters between pregnant and non-pregnant women in this study (p<0.05), except Amylase and total cholesterol (p>0.05). Hematological and Clinical Chemistry reference ranges established in this study showed significant gender differences. Pregnant women also differed from non-pregnant females and during pregnancy. This is the first of such comprehensive study to establish reference values among adult Nigerians and difference observed underscore the need to establish reference values for different populations.
Sugianto, Jessica Z; Stewart, Brian; Ambruzs, Josephine M; Arista, Amanda; Park, Jason Y; Cope-Yokoyama, Sandy; Luu, Hung S
2015-01-01
To implement Lean principles to accommodate expanding volumes of gastrointestinal biopsies and to improve laboratory processes overall. Our continuous improvement (kaizen) project analyzed the current state for gastrointestinal biopsy handling using value-stream mapping for specimens obtained at a 487-bed tertiary care pediatric hospital in Dallas, Texas. We identified non-value-added time within the workflow process, from receipt of the specimen in the histology laboratory to the delivery of slides and paperwork to the pathologist. To eliminate non-value-added steps, we implemented the changes depicted in a revised-state value-stream map. Current-state value-stream mapping identified a total specimen processing time of 507 minutes, of which 358 minutes were non-value-added. This translated to a process cycle efficiency of 29%. Implementation of a revised-state value stream resulted in a total process time reduction to 238 minutes, of which 89 minutes were non-value-added, and an improved process cycle efficiency of 63%. Lean production principles of continuous improvement and waste elimination can be successfully implemented within the clinical laboratory.
2017-09-27
ARL-TR-8161•SEP 2017 US Army Research Laboratory Excluding Noise from Short Krylov Subspace Approximations to the Truncated Singular Value...originator. ARL-TR-8161•SEP 2017 US Army Research Laboratory Excluding Noise from Short Krylov Subspace Approximations to the Truncated Singular Value...unlimited. October 2015–January 2016 US Army Research Laboratory ATTN: RDRL-CIH-C Aberdeen Proving Ground, MD 21005-5066 primary author’s email
Regional ADC values of the normal brain: differences due to age, gender, and laterality.
Naganawa, Shinji; Sato, Kimihide; Katagiri, Toshio; Mimura, Takeo; Ishigaki, Takeo
2003-01-01
The purpose of this study was to evaluate the stability of measurement for apparent diffusion coefficient (ADC) values in normal brain, to clarify the effect of aging on ADC values, to compare ADC values between men and women, and to compare ADC values between right and left sides of the brain. To evaluate the stability of measurements, five normal volunteers (four men and one woman) were examined five times on different days. Then, 294 subjects with normal MR imaging (147 men and 147 women; age range 20-89 years) were measured. The ADC measurement in normal volunteers was stable. The ADC values stayed within the 5% deviation of average values in all volunteers (mean+/-standard deviation 2.3+/-1.2%). The ADC values gradually increased by aging in all regions. In thalamus, no significant difference was seen between right and left in the subjects under 60 years; however, right side showed higher values in the subjects over 60 years (p<0.01). In the subjects under 60 years, women showed higher values in right frontal, bilateral thalamus, and temporal (p<0.01); however, in the subjects over 60 years, no region showed difference between men and women. The knowledge obtained in this study may be helpful to understand the developmental and aging mechanisms of normal brain and may be useful for the future quantitative study as a reference.
Insomnia with physiological hyperarousal is associated with hypertension.
Li, Yun; Vgontzas, Alexandros N; Fernandez-Mendoza, Julio; Bixler, Edward O; Sun, Yuanfeng; Zhou, Junying; Ren, Rong; Li, Tao; Tang, Xiangdong
2015-03-01
Previous studies have suggested that insomnia with objective short sleep duration is associated with a higher risk of hypertension, and it has been speculated that the underlying mechanism is physiological hyperarousal. In this study, we tested whether insomnia with physiological hyperarousal measured by Multiple Sleep Latency Test (MSLT), a standard test of sleepiness/alertness, is associated with increased risk of hypertension. Two hundred nineteen chronic insomniacs and 96 normal sleepers were included in this study. Chronic insomnia was defined based on standard diagnostic criteria with symptoms lasting ≥6 months. All subjects underwent 1 night in laboratory polysomnography followed by a standard MSLT. We used the median mean MSLT value (ie, >14 minutes) and the 75th percentile of mean MSLT value (ie, >17 minutes) to define hyperarousal. Hypertension was defined based either on blood pressure measures or on diagnosis treatment by a physician. After controlling for age, sex, body mass index, apnea-hypopnea index, diabetes mellitus, smoking, alcohol, and caffeine use, insomnia combined with MSLT >14 minutes increased the odds of hypertension by 300% (odds ratio=3.27; 95% confidence interval=1.20-8.96), whereas insomnia combined with MSLT >17 minutes increased even further the odds of hypertension by 400% (odds ratio=4.33; 95% confidence interval=1.48-12.68) compared with normal sleepers with MSLT ≤14 minutes. Insomnia associated with physiological hyperarousal is associated with a significant risk of hypertension. Long MSLT values may be a reliable index of the physiological hyperarousal and biological severity of chronic insomnia. © 2015 American Heart Association, Inc.
Regional cerebral blood flow in childhood headache
DOE Office of Scientific and Technical Information (OSTI.GOV)
Roach, E.S.; Stump, D.A.
1989-06-01
Regional cerebral blood flow (rCBF) was measured in 16 cranial regions in 23 children and adolescents with frequent headaches using the non-invasive Xenon-133 inhalation technique. Blood flow response to 5% carbon dioxide (CO2) was also determined in 21 patients, while response to 50% oxygen was measured in the two patients with hemoglobinopathy. Included were 10 patients with a clinical diagnosis of migraine, 4 with musculoskeletal headaches, and 3 with features of both types. Also studied were 2 patients with primary thrombocythemia, 2 patients with hemoglobinopathy and headaches, 1 patient with polycythemia, and 1 with headaches following trauma. With two exceptions,more » rCBF determinations were done during an asymptomatic period. Baseline rCBF values tended to be higher in these young patients than in young adults done in our laboratory. Localized reduction in the expected blood flow surge after CO2 inhalation, most often noted posteriorly, was seen in 8 of the 13 vascular headaches, but in none of the musculoskeletal headache group. Both patients with primary thrombocythemia had normal baseline flow values and altered responsiveness to CO2 similar to that seen in migraineurs; thus, the frequently reported headache and transient neurologic signs with primary thrombocythemia are probably not due to microvascular obstruction as previously suggested. These data support the concept of pediatric migraine as a disorder of vasomotor function and also add to our knowledge of normal rCBF values in younger patients. Demonstration of altered vasomotor reactivity to CO2 could prove helpful in children whose headache is atypical.« less
... Normal Results Normal values are 60% to 150% inhibition. Normal value ranges may vary slightly among different ... Health Solutions. About MedlinePlus Site Map FAQs Customer Support Get email updates Subscribe to RSS Follow us ...
... Normal Results Normal values are 60% to 150% inhibition. Normal value ranges may vary slightly among different ... Health Solutions. About MedlinePlus Site Map FAQs Customer Support Get email updates Subscribe to RSS Follow us ...
Park, Jae-Hyeong; Choi, Jin-Oh; Park, Seung Woo; Cho, Goo-Yeong; Oh, Jin Kyung; Lee, Jae-Hwan; Seong, In-Whan
2018-02-01
Right ventricular (RV) strain values by 2-dimensional strain echocardiography (STE) can be used as objective markers of RV systolic function. However, there is little data about normal reference RV strain values according to age and gender. We measured normal RV strain values by STE. RV strain values were analyzed from the digitally stored echocardiographic images from NORMAL (Normal echOcardiogRaphic diMensions and functions in KoreAn popuLation) study for the measurement of normal echocardiographic values performed in 23 Korean university hospitals. We enrolled total 1003 healthy persons in the NORMAL study. Of them, we analyzed 2-dimensional RV strain values in 493 subjects (261 females, mean 47 ± 15 years old) only with echocardiographic images by GE machines. Their LV systolic and diastolic functions were normal. RV fractional area change was 48 ± 6% and tricuspid annular plane systolic excursion was 23 ± 3 mm. Total RV global longitudinal peak systolic strain (RVGLS total ) was -21.5 ± 3.2%. Females had higher absolute RVGLS total (-22.3 ± 3.3 vs -20.7 ± 2.9%, p < 0.001) than males. Younger (<50 years old) females had higher absolute RVGLS total (-22.9 ± 3.2 vs -20.5 ± 2.8%, p < 0.001) than age matched males. RVGLS total in females gradually increased according to age (p for trend = 0.002) and becomes almost similar in age ≥50 years. However, this trend was not seen in males (p for trend = 0.287), and younger males had similar RVGLS total value to that of older males (age ≥50 years, -20.5 ± 2.8 vs -20.9 ± 3.1%, p = 0.224). We calculated normal RVGLS values in normal population. Females have higher absolute strain values than males, especially in younger age groups (<50 years old).
Armando García-Miranda, L; Contreras, I; Estrada, J A
2014-04-01
To determine reference values for full blood count parameters in a population of children 8 to 12 years old, living at an altitude of 2760 m above sea level. Our sample consisted of 102 individuals on whom a full blood count was performed. The parameters included: total number of red blood cells, platelets, white cells, and a differential count (millions/μl and %) of neutrophils, lymphocytes, monocytes, eosinophils and basophils. Additionally, we obtained values for hemoglobin, hematocrit, mean corpuscular volume, mean corpuscular hemoglobin, concentration of corpuscular hemoglobin and red blood cell distribution width. The results were statistically analyzed with a non-parametric test, to divide the sample in quartiles and obtain the lower and upper limits for our intervals. Moreover, the values for the intervals obtained from this analysis were compared to intervals obtained estimating+- 2 standard deviations above and below from our mean values. Our results showed significant differences compared to normal interval values reported for the adult Mexican population in most of the parameters studied. The full blood count is an important laboratory test used routinely for the initial assessment of a patient. Values of full blood counts in healthy individuals vary according to gender, age and geographic location; therefore, each population should have its own reference values. Copyright © 2013 Asociación Española de Pediatría. Published by Elsevier Espana. All rights reserved.
Correlation of laboratory and production freeze drying cycles.
Kuu, Wei Y; Hardwick, Lisa M; Akers, Michael J
2005-09-30
The purpose of this study was to develop the correlation of cycle parameters between a laboratory and a production freeze-dryer. With the established correlation, key cycle parameters obtained using a laboratory dryer may be converted to those for a production dryer with minimal experimental efforts. In order to develop the correlation, it was important to consider the contributions from the following freeze-drying components: (1) the dryer, (2) the vial, and (3) the formulation. The critical parameters for the dryer are the shelf heat transfer coefficient and shelf surface radiation emissivity. The critical parameters for the vial are the vial bottom heat transfer coefficients (the contact parameter Kcs and separation distance lv), and vial top heat transfer coefficient. The critical parameter of the formulation is the dry layer mass transfer coefficient. The above heat and mass transfer coefficients were determined by freeze-drying experiments in conjunction with mathematical modeling. With the obtained heat and mass transfer coefficients, the maximum product temperature, Tbmax, during primary drying was simulated using a primary drying subroutine as a function of the shelf temperature and chamber pressure. The required shelf temperature and chamber pressure, in order to perform a successful cycle run without product collapse, were then simulated based on the resulting values of Tbmax. The established correlation approach was demonstrated by the primary drying of the model formulation 5% mannitol solution. The cycle runs were performed using a LyoStar dryer as the laboratory dryer and a BOC Edwards dryer as the production dryer. The determined normalized dried layer mass transfer resistance for 5% mannitol is expressed as RpN=0.7313+17.19l, where l is the receding dry layer thickness. After demonstrating the correlation approach using the model formulation 5% mannitol, a practical comparison study was performed for the actual product, the lactate dehydrogenase (LDH) formulation. The determined normalized dried layer mass transfer resistance for the LDH formulation is expressed as RpN=4.344+10.85l. The operational templates Tbmax and primary drying time were also generated by simulation. The cycle run for the LDH formulation using the Edwards production dryer verified that the cycle developed in a laboratory freeze-dryer was transferable at the production scale.
Customer satisfaction assessment at the Pacific Northwest National Laboratory
DOE Office of Scientific and Technical Information (OSTI.GOV)
DN Anderson; ML Sours
2000-03-23
The Pacific Northwest National Laboratory (PNNL) is developing and implementing a customer satisfaction assessment program (CSAP) to assess the quality of research and development provided by the laboratory. This report presents the customer survey component of the PNNL CSAP. The customer survey questionnaire is composed of two major sections: Strategic Value and Project Performance. Both sections contain a set of questions that can be answered with a 5-point Likert scale response. The strategic value section consists of five questions that are designed to determine if a project directly contributes to critical future national needs. The project Performance section consists ofmore » nine questions designed to determine PNNL performance in meeting customer expectations. A statistical model for customer survey data is developed and this report discusses how to analyze the data with this model. The properties of the statistical model can be used to establish a gold standard or performance expectation for the laboratory, and then to assess progress. The gold standard is defined using laboratory management input--answers to four questions, in terms of the information obtained from the customer survey: (1) What should the average Strategic Value be for the laboratory project portfolio? (2) What Strategic Value interval should include most of the projects in the laboratory portfolio? (3) What should average Project Performance be for projects with a Strategic Value of about 2? (4) What should average Project Performance be for projects with a Strategic Value of about 4? To be able to provide meaningful answers to these questions, the PNNL customer survey will need to be fully implemented for several years, thus providing a link between management perceptions of laboratory performance and customer survey data.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Anthony Hendrickson; Brian Mennecke; Kevin Scheibe
2005-10-01
Modern, forensics laboratories need Laboratory Information Management Systems (LIMS) implementations that allow the lab to track evidentiary items through their examination lifecycle and also serve all pertinent laboratory personnel. The research presented here presents LIMS core requirements as viewed by respondents serving in different forensic laboratory capacities as well as different forensic laboratory environments. A product-development methodology was employed to evaluate the relative value of the key features that constitute a LIMS, in order to develop a set of relative values for these features and the specifics of their implementation. In addition to the results of the product development analysis,more » this paper also provides an extensive review of LIMS and provides an overview of the preparation and planning process for the successful upgrade or implementation of a LIMS. Analysis of the data indicate that the relative value of LIMS components are viewed differently depending upon respondents' job roles (i.e., evidence technicians, scientists, and lab management), as well as by laboratory size. Specifically, the data show that: (1) Evidence technicians place the most value on chain of evidence capabilities and on chain of custody tracking; (2) Scientists generally place greatest value on report writing and generation, and on tracking daughter evidence that develops during their analyses; (3) Lab. Managers place the greatest value on chain of custody, daughter evidence, and not surprisingly, management reporting capabilities; and (4) Lab size affects LIMS preference in that, while all labs place daughter evidence tracking, chain of custody, and management and analyst report generation as their top three priorities, the order of this prioritization is size dependent.« less
A nonphosphaturic mesenchymal tumor mixed connective tissue variant of the sacrum.
Mavrogenis, Andreas F; Sakellariou, Vasileios I; Soultanis, Konstantinos; Mahera, Helen; Korres, Demetrios S; Papagelopoulos, Panayiotis J
2010-11-02
Tumor-induced or oncogenic osteomalacia is a rare paraneoplastic syndrome characterized by overproduction of fibroblast growth factor-23 as a phosphaturic agent and renal phosphate wasting. A range of predominantly mesenchymal neoplasms have been associated with tumor-induced osteomalacia and classified as phosphaturic mesenchymal tumor mixed connective tissues. However, phosphaturic mesenchymal tumor mixed connective tissues could be nonphosphaturic in the first stage of the disease, either because the tumors are resected early in the clinical course or because the patient's osteomalacia was attributed to another cause. This article presents a case of a 42-year-old woman with a 2-year history of low back and right leg pain. Laboratory examinations including serum and urine calcium and phosphorous were within normal values. Imaging of the lumbar spine and pelvis showed an osteolytic lesion occupying the right sacral wing. Histology was unclear. Reverse-transcription polymerase chain reaction analysis for fibroblast growth factor-23 was positive and confirmed the diagnosis of phosphaturic mesenchymal tumor mixed connective tissues. Preoperative selective arterial embolization and complete intralesional excision, bone grafting, and instrumented fusion from L4 to L5 to the iliac wings bilaterally was performed. Postoperative recovery was uneventful. Neurological deficits were not observed. A lumbopelvic corset was applied for 3 months. At 12 months, the patient was asymptomatic. Serum and urine values of calcium and phosphorous were normal throughout the follow-up evaluation. Copyright 2010, SLACK Incorporated.
Effects of shear load on frictional healing
NASA Astrophysics Data System (ADS)
Ryan, K. L.; Marone, C.
2014-12-01
During the seismic cycle of repeated earthquake failure, faults regain strength in a process known as frictional healing. Laboratory studies have played a central role in illuminating the processes of frictional healing and fault re-strengthening. These studies have also provided the foundation for laboratory-derived friction constitutive laws, which have been used extensively to model earthquake dynamics. We conducted laboratory experiments to assess the affect of shear load on frictional healing. Frictional healing is quantified during slide-hold-slide (SHS) tests, which serve as a simple laboratory analog for the seismic cycle in which earthquakes (slide) are followed by interseismic quiescence (hold). We studied bare surfaces of Westerly granite and layers of Westerly granite gouge (thickness of 3 mm) at normal stresses from 4-25 MPa, relative humidity of 40-60%, and loading and unloading velocities of 10-300 μm/s. During the hold period of SHS tests, shear stress on the sample was partially removed to investigate the effects of shear load on frictional healing and to isolate time- and slip-dependent effects on fault healing. Preliminary results are consistent with existing works and indicate that frictional healing increases with the logarithm of hold time and decreases with normalized shear stress τ/τf during the hold. During SHS tests with hold periods of 100 seconds, healing values ranged from (0.013-0.014) for τ/τf = 1 to (0.059-0.063) for τ/τf = 0, where τ is the shear stress during the hold period and τf is the shear stress during steady frictional sliding. Experiments on bare rock surfaces and with natural and synthetic fault gouge materials are in progress. Conventional SHS tests (i.e. τ/τf = 1) are adequately described by the rate and state friction laws. However, previous experiments in granular quartz suggest that zero-stress SHS tests are not well characterized by either the Dieterich or Ruina state evolution laws. We are investigating the processes that produce shear stress dependent frictional healing, alternate forms of the state evolution law, and comparing results for friction of bare rock surfaces and granular fault gouge.
Demixing-stimulated lane formation in binary complex plasma
DOE Office of Scientific and Technical Information (OSTI.GOV)
Du, C.-R.; Jiang, K.; Suetterlin, K. R.
2011-11-29
Recently lane formation and phase separation have been reported for experiments with binary complex plasmas in the PK3-Plus laboratory onboard the International Space Station (ISS). Positive non-additivity of particle interactions is known to stimulate phase separation (demixing), but its effect on lane formation is unknown. In this work, we used Langevin dynamics (LD) simulation to probe the role of non-additivity interactions on lane formation. The competition between laning and demixing leads to thicker lanes. Analysis based on anisotropic scaling indices reveals a crossover from normal laning mode to a demixing-stimulated laning mode. Extensive numerical simulations enabled us to identify amore » critical value of the non-additivity parameter {Delta} for the crossover.« less
Feline focus: Diagnostic testing for feline thyroid disease: hyperthyroidism.
Peterson, Mark E
2013-08-01
In older cats presenting with clinical features of hyperthyroidism, confirming the diagnosis of thyroid disease is usually straightforward. However, the potential for false-negative and false-positive results exists with all thyroid function tests, especially when used for routine screening of large numbers of asymptomatic cats. Therefore, all thyroid function test results must be interpreted in light of the cat's history, clinical signs, and other laboratory findings. If a high serum thyroxine (T4) value is found in a cat that lacks clinical signs of hyperthyroidism, or if hyperthyroidism is suspected in a cat with normal total T4 concentrations, repeating the total T4 analysis, determining the free T4 concentration, or performing thyroid scintigraphy may be needed to confirm the diagnosis.
Measurement of the Neutrino Mixing Angle θ23 in NOvA
NASA Astrophysics Data System (ADS)
Adamson, P.; Aliaga, L.; Ambrose, D.; Anfimov, N.; Antoshkin, A.; Arrieta-Diaz, E.; Augsten, K.; Aurisano, A.; Backhouse, C.; Baird, M.; Bambah, B. A.; Bays, K.; Behera, B.; Bending, S.; Bernstein, R.; Bhatnagar, V.; Bhuyan, B.; Bian, J.; Blackburn, T.; Bolshakova, A.; Bromberg, C.; Brown, J.; Brunetti, G.; Buchanan, N.; Butkevich, A.; Bychkov, V.; Campbell, M.; Catano-Mur, E.; Childress, S.; Choudhary, B. C.; Chowdhury, B.; Coan, T. E.; Coelho, J. A. B.; Colo, M.; Cooper, J.; Corwin, L.; Cremonesi, L.; Cronin-Hennessy, D.; Davies, G. S.; Davies, J. P.; Derwent, P. F.; Desai, S.; Dharmapalan, R.; Ding, P.; Djurcic, Z.; Dukes, E. C.; Duyang, H.; Edayath, S.; Ehrlich, R.; Feldman, G. J.; Frank, M. J.; Gabrielyan, M.; Gallagher, H. R.; Germani, S.; Ghosh, T.; Giri, A.; Gomes, R. A.; Goodman, M. C.; Grichine, V.; Group, R.; Grover, D.; Guo, B.; Habig, A.; Hartnell, J.; Hatcher, R.; Hatzikoutelis, A.; Heller, K.; Himmel, A.; Holin, A.; Hylen, J.; Jediny, F.; Judah, M.; Kafka, G. K.; Kalra, D.; Kasahara, S. M. S.; Kasetti, S.; Keloth, R.; Kolupaeva, L.; Kotelnikov, S.; Kourbanis, I.; Kreymer, A.; Kumar, A.; Kurbanov, S.; Lang, K.; Lee, W. M.; Lin, S.; Liu, J.; Lokajicek, M.; Lozier, J.; Luchuk, S.; Maan, K.; Magill, S.; Mann, W. A.; Marshak, M. L.; Matera, K.; Matveev, V.; Méndez, D. P.; Messier, M. D.; Meyer, H.; Miao, T.; Miller, W. H.; Mishra, S. R.; Mohanta, R.; Moren, A.; Mualem, L.; Muether, M.; Mufson, S.; Murphy, R.; Musser, J.; Nelson, J. K.; Nichol, R.; Niner, E.; Norman, A.; Nosek, T.; Oksuzian, Y.; Olshevskiy, A.; Olson, T.; Paley, J.; Pandey, P.; Patterson, R. B.; Pawloski, G.; Pershey, D.; Petrova, O.; Petti, R.; Phan-Budd, S.; Plunkett, R. K.; Poling, R.; Potukuchi, B.; Principato, C.; Psihas, F.; Radovic, A.; Rameika, R. A.; Rebel, B.; Reed, B.; Rocco, D.; Rojas, P.; Ryabov, V.; Sachdev, K.; Sail, P.; Samoylov, O.; Sanchez, M. C.; Schroeter, R.; Sepulveda-Quiroz, J.; Shanahan, P.; Sheshukov, A.; Singh, J.; Singh, J.; Singh, P.; Singh, V.; Smolik, J.; Solomey, N.; Song, E.; Sousa, A.; Soustruznik, K.; Strait, M.; Suter, L.; Talaga, R. L.; Tamsett, M. C.; Tas, P.; Thayyullathil, R. B.; Thomas, J.; Tian, X.; Tognini, S. C.; Tripathi, J.; Tsaris, A.; Urheim, J.; Vahle, P.; Vasel, J.; Vinton, L.; Vold, A.; Vrba, T.; Wang, B.; Wetstein, M.; Whittington, D.; Wojcicki, S. G.; Wolcott, J.; Yadav, N.; Yang, S.; Zalesak, J.; Zamorano, B.; Zwaska, R.; NOvA Collaboration
2017-04-01
This Letter reports new results on muon neutrino disappearance from NOvA, using a 14 kton detector equivalent exposure of 6.05 ×1 020 protons on target from the NuMI beam at the Fermi National Accelerator Laboratory. The measurement probes the muon-tau symmetry hypothesis that requires maximal θ23 mixing (θ23=π /4 ). Assuming the normal mass hierarchy, we find Δ m322 =(2.67 ±0.11 )×10-3 eV2 and sin2θ23 at the two statistically degenerate values 0.40 4-0.022+0.030 and 0.62 4-0.030+0.022, both at the 68% confidence level. Our data disfavor the maximal mixing scenario with 2.6 σ significance.
Measurement of the neutrino mixing angle θ 23 in NOvA
Adamson, P.; Aliaga, L.; Ambrose, D.; ...
2017-04-10
This Letter reports new results on muon neutrino disappearance from NOvA, using a 14 kton detector equivalent exposure ofmore » $$6.05\\times10^{20}$$ protons-on-target from the NuMI beam at the Fermi National Accelerator Laboratory. The measurement probes the muon-tau symmetry hypothesis that requires maximal mixing ($$\\theta_{23} = \\pi/4$$). Assuming the normal mass hierarchy, we find $$\\Delta m^2 = (2.67 \\pm 0.11)\\times 10^{-3}$$ eV$^2$ and $$\\sin^2 \\theta_{23}$$ at the two statistically degenerate values $$0.404^{+0.030}_{-0.022}$$ and $$0.624^{+0.022}_{-0.030}$$, both at the 68% confidence level. Finally, our data disfavor the maximal mixing scenario with 2.6 $$\\sigma$$ significance.« less
Does a normal foetus really have a future of value? A reply to Marquis.
Lovering, Robert P
2005-04-01
The traditional approach to the abortion debate revolves around numerous issues, such as whether the foetus is a person, whether the foetus has rights, and more. Don Marquis suggests that this traditional approach leads to a standoff and that the abortion debate 'requires a different strategy.' Hence his 'future of value' strategy, which is summarized as follows: (1) A normal foetus has a future of value. (2) Depriving a normal foetus of a future of value imposes a misfortune on it. (3) Imposing a misfortune on a normal foetus is prima facie wrong. (4) Therefore, depriving a normal foetus of a future of value is prima facie wrong. (5) Killing a normal foetus deprives it of a future value. (6) Therefore, killing a normal foetus is prima facie wrong. In this paper, I argue that Marquis's strategy is not different since it involves the concept of person--a concept deeply rooted in the traditional approach. Specifically, I argue that futures are valuable insofar as they are not only dominated by goods of consciousness, but are experienced by psychologically continuous persons. Moreover, I argue that his strategy is not sound since premise (1) is false. Specifically, I argue that a normal foetus, at least during the first trimester, is not a person. Thus, during that stage of development it is not capable of experiencing its future as a psychologically continuous person and, hence, it does not have a future of value.
Dynamic divisive normalization predicts time-varying value coding in decision-related circuits.
Louie, Kenway; LoFaro, Thomas; Webb, Ryan; Glimcher, Paul W
2014-11-26
Normalization is a widespread neural computation, mediating divisive gain control in sensory processing and implementing a context-dependent value code in decision-related frontal and parietal cortices. Although decision-making is a dynamic process with complex temporal characteristics, most models of normalization are time-independent and little is known about the dynamic interaction of normalization and choice. Here, we show that a simple differential equation model of normalization explains the characteristic phasic-sustained pattern of cortical decision activity and predicts specific normalization dynamics: value coding during initial transients, time-varying value modulation, and delayed onset of contextual information. Empirically, we observe these predicted dynamics in saccade-related neurons in monkey lateral intraparietal cortex. Furthermore, such models naturally incorporate a time-weighted average of past activity, implementing an intrinsic reference-dependence in value coding. These results suggest that a single network mechanism can explain both transient and sustained decision activity, emphasizing the importance of a dynamic view of normalization in neural coding. Copyright © 2014 the authors 0270-6474/14/3416046-12$15.00/0.
Ganidagli, Safa Ersen; Altunoren, Orcun; Erken, Ertuğrul; Isık, Ismet Onder; Ganidagli, Berivan; Eren, Necmi; Yavuz, Yasemin Coskun; Gungor, Ozkan
2017-10-01
Hemoglobin variability is a common problem among hemodialysis patients. We have previously demonstrated an association between Hb variability and left ventricular mass index. In this study, we investigated a possible relation between Hb variability and carotid intima-media thickness (CIMT). Twelve-month hemoglobin (Hb) values of 135 patients on maintenance hemodialysis were examined retrospectively. The range of 11-12 gr/dl was accepted as normal according to the KDOQI guidelines. Hemoglobin levels were classified as: Hb < 11 gr/dl:Low, Hb = 11-12 gr/dl:Normal and Hb > 12 gr/dl:High. According to 12-month Hb trajectory, the patients were divided into three groups: low-normal (LN), normal-high (NH) and low-high (LH). The CIMT measurements were taken on common carotid arteries bilaterally, and the average of these measurements were taken. The groups were compared in terms of CIMT measurements, demographic and laboratory features. The LN, NH and LH groups were similar in terms of age, gender, incidence of diabetes mellitus, hypertension and cardiovascular diseases. Duration of hemodialysis, hemodialysis adequacy, serum lipids and CaxP products were also similar among the groups. The mean CIMT value was 0.601 ± 0.107, 0.744 ± 0.139 and 0.604 ± 0.134 mm in the LN, LH and NH groups, respectively (p < 0.001). CIMT was significantly higher in LH than in the other two groups. In our study, when the three groups with similar risk factors for atherosclerosis were examined, we found that the LH group with the highest hemoglobin variability has the highest CIMT. This study is the first study to demonstrate that Hb variability is associated with an increase in CIMT in HD patients.
Urrechaga, E
2016-12-01
ADAMS ™ A1cHA-8180T is a HPLC system; within 3.5 min, it quantifies HbF, HbA 2 , and HbA 0 and flags abnormal peaks. We evaluate its analytical performance for routine estimation of HbA 2 and HbF, and critical tests were performed for identifying β-thalassemia carriers. Trueness imprecision, carry over, linearity, and effect of anemia were evaluated according to ICLH, ICLS, or manufacture's guidelines. Comparison (ADAMS ™ A1c HA-8160T) was performed by running 400 samples from healthy subjects, 30 alpha and 80 beta carriers (range: 1.9-5.7 %). Trueness - HbA 2 2.7 %, bias 0.81 %; HbA 2 5.8 %, bias 0.38 %. HbA 2 4.0% is not affected by Hb in the range 221-40 g/L. Carry over was negligible. Within run: normal control - CV 1.5 %, high control - CV 0.9 %.Within laboratory: normal control - total CV% 1.59%; high control - 0.92 %. Linearity - y = 1.034x - 0.17, R 2 = 0.998 (range: 2.8-4.8%).Method comparison - y = 0.93x + 0.22, R 2 = 0.997. HbF imprecision CVs between 0.66 and 1.24% and trueness between 0 and 2.8%. Linearity - y = 1.088x - 0.27, R 2 = 0.999 (0.1-5.7%). ADAMS ™ A1c HA-8180T provides a rapid and reliable separation of HbA 2 . The measurement is accurate and reproducible, which is needed because of the slight difference between normal and pathological values. The gap in HbA 2 values between normal subjects and β-thalassemia carriers makes this an appropriate method for rapid screening for carriers. © 2016 John Wiley & Sons Ltd.
DOE Office of Scientific and Technical Information (OSTI.GOV)
O'Keefe, J.H. Jr.; Zinsmeister, A.R.; Gibbons, R.J.
1989-06-01
Characterization of left ventricular function is important in managing patients with coronary artery disease. Although many methods are available to assess left ventricular function, most are either expensive, invasive, or both. In this study, we examined the ability of normal or near-normal resting electrocardiographic findings to predict resting left ventricular ejection fraction, measured by resting radionuclide angiography, in 874 patients with chest pain and suspected coronary artery disease. A retrospective review was undertaken of 4,410 Mayo Clinic patients who underwent rest and exercise radionuclide ventriculography for the evaluation of chest pain and known or suspected coronary artery disease; of these,more » 874 patients met the inclusion criteria for the current study. A 15-lead electrocardiogram, which was interpreted by the cardiologist or cardiology trainee working in the laboratory, was obtained at the same evaluation as the radionuclide study. In 590 patients with no previous history of a myocardial infarction and entirely normal resting electrocardiographic results without nonspecific ST-T wave abnormalities, the mean left ventricular ejection fraction was 0.63 +/- 0.004, and 559 patients (95%) had a normal resting ejection fraction (defined as 0.50 or more). Both nonspecific ST-T wave abnormalities (p less than 0.001) and, to a lesser degree, a history of myocardial infarction (p = 0.06) were independent predictors of an abnormal resting ejection fraction. In 185 patients with nonspecific ST-T wave abnormalities and no history of myocardial infarction, the mean left ventricular ejection fraction was 0.61 +/- 0.009, and 85% had a normal resting ejection fraction.« less
Using iRT, a normalized retention time for more targeted measurement of peptides.
Escher, Claudia; Reiter, Lukas; MacLean, Brendan; Ossola, Reto; Herzog, Franz; Chilton, John; MacCoss, Michael J; Rinner, Oliver
2012-04-01
Multiple reaction monitoring (MRM) has recently become the method of choice for targeted quantitative measurement of proteins using mass spectrometry. The method, however, is limited in the number of peptides that can be measured in one run. This number can be markedly increased by scheduling the acquisition if the accurate retention time (RT) of each peptide is known. Here we present iRT, an empirically derived dimensionless peptide-specific value that allows for highly accurate RT prediction. The iRT of a peptide is a fixed number relative to a standard set of reference iRT-peptides that can be transferred across laboratories and chromatographic systems. We show that iRT facilitates the setup of multiplexed experiments with acquisition windows more than four times smaller compared to in silico RT predictions resulting in improved quantification accuracy. iRTs can be determined by any laboratory and shared transparently. The iRT concept has been implemented in Skyline, the most widely used software for MRM experiments. © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Gravity, Body Mass and Composition, and Metabolic Rate
NASA Technical Reports Server (NTRS)
Pace, N.; Smith, A. H.
1985-01-01
Metabolic rate and body composition as a function of sex and age were defined in 5 species of common laboratory mammals, the mouse, hamster, rat, guinea pig and rabbit. Oxygen consumption and carbon dioxide production rates were measured individually in 6 male and 6 female animals for each of 8 age cohorts ranging from 1 month to 2 years, and for each of the species. From the results it is evident that among these small mammals there is no indication of scaling of muscularity to body size, despite the 100-fold difference in body mass represented by the skeletal musculature seems to reach a pronounced peak value at age 2 to 3 months and then declines, the fraction of the fat-free body represented by other body components in older animals must increase complementarily. Under normal gravity conditions muscularity in small laboratory mammals displays large, systematic variation as a function both of species and age. This variation must be considered when such animals are subjects of experiments to study the effects of altered gravitational loading on the skeletal musculature of the mammal.
Hyperuricemia in the inhabitants of the Marshall Islands
DOE Office of Scientific and Technical Information (OSTI.GOV)
Adams, W.H.; Harper, J.A.; Heotis, P.M.
1984-06-01
Annual medical examinations are conducted by Brookhaven National Laboratory (BNL) for a population of Marshallese who were accidentally exposed to radioactive fallout in 1954, for a comparison population, and for all inhabitants of the atolls of Rongelap and Utirik. Disease surveillance includes analysis of serum samples. Elevated serum uric acid (SUA) levels are common along Pacific populations, and modifying environmental factors have been investigated as a cause for this finding. The authors have studied SUA levels of people living in the Marshall Islands, and have found elevated values similar to those reported for other Micronesian populations. The nearly Gaussian distributionmore » of individual serum uric acid values for men, and for women less than or equal to45 years of age, indicates that the elevation is due to a regularized increase in serum uric acid rather than to a subpopulation that has pathologic hyperuricemia. The higher serum uric acid levels appear, therefore, to be normal for the Marshallese, a conclusion supported by the infrequency of clinical gout in the population tested.« less
NASA Technical Reports Server (NTRS)
Brizzee, K. R.; Ordy, J. M.; Dunlap, W. P.; Kendrick, R.; Wengenack, T. M.
1988-01-01
Due to its small size, lower cost, tractable nature, successful breeding in captivity and its status near the middle of the primate phylogenetic scale, the squirrel monkey has become an attractive primate model for basic and biomedical research. Although the squirrel monkey now is being used more extensively in many laboratories with diverse interests, only fragmentary reports have been published regarding basic physiological characteristics, or baseline blood reference values of different phenotypes, particularly blood gases, hematology and serum chemical constituents. It is becoming recognized increasingly that these baseline blood reference values are important not only in the care and maintenance of the squirrel monkey, but are critical for assessing normal physiological status, as well as the effects of various experimental treatments. The purpose of this study was to compare differences in blood gases, electrolytes, hematology, blood glucose and cortisol among young and old Bolivian (Roman type) and Colombian (Gothic type) phenotypes of the squirrel monkey.
NASA Astrophysics Data System (ADS)
Limantara, A. D.; Widodo, A.; Winarto, S.; Krisnawati, L. D.; Mudjanarko, S. W.
2018-04-01
The use of natural gravel (rivers) as concrete mixtures is rarely encountered after days of demands for a higher strength of concrete. Moreover, today people have found High-Performance Concrete which, when viewed from the rough aggregate consisted mostly of broken stone, although the fine grain material still used natural sand. Is it possible that a mixture of concrete using natural gravel as a coarse aggregate is capable of producing concrete with compressive strength equivalent to a concrete mixture using crushed stone? To obtain information on this, a series of tests on concrete mixes with crude aggregates of Kalitelu Crusher, Gondang, Tulungagung and natural stone (river gravel) from the Brantas River, Ngujang, Tulungagung in the Materials Testing Laboratory Tugu Dam Construction Project, Kab. Trenggalek. From concrete strength test results using coarse material obtained value 19.47 Mpa, while the compressive strength of concrete with a mixture of crushed stone obtained the value of 21.12 Mpa.
On the value of routine prothrombin time screening in elective neurosurgical procedures.
Dützmann, Stephan; Gessler, Florian; Marquardt, Gerhard; Seifert, Volker; Senft, Christian
2012-11-01
The authors performed a study to evaluate whether preoperative assessment of prothrombin time (PT) is mandatory in patients undergoing routinely planned neurosurgical procedures. The charts of all patients admitted to general wards of the authors' department for routinely planned surgery (excluding trauma and ICU patients) between 2006 and 2010 were retrospectively reviewed. The authors assessed preoperative PT and the clinical courses of all patients, with special consideration for patients receiving coagulation factor substitution. All cases involving hemorrhagic complications were analyzed in detail with regard to pre- and postoperative PT abnormalities. Prothrombin time was expressed as the international normalized ratio, and values greater than 1.28 were regarded as elevated. Clinical courses and PT values of 4310 patients were reviewed. Of these, 33 patients (0.7%) suffered hemorrhagic complications requiring repeat surgery. Thirty-one patients (94%) had a normal PT before the initial operation, while 2 patients had slightly elevated PT values of 1.33 and 1.65, which were anticipated based on the patient's history. In the latter 2 cases, surgery was performed without prior correction of PT. Preoperatively, PT was elevated in 78 patients (1.8%). In 73 (93.6%) of the 78 patients, the PT elevation was expected and explained by each patient's medical history. In only 5 (0.1%) of 4310 patients did we find an unexpected PT elevation (mean 1.53, range 1.37-1.74). All 5 patients underwent surgery without complications, while 2 had received coagulation factor substitution preoperatively, as requested by the surgeon, because of an estimated risk of bleeding complications. None of the 5 patients received coagulation factor substitution postoperatively, and later detailed laboratory studies ruled out single coagulation factor deficiencies. There was no statistically significant association between preoperatively elevated PT levels and the occurrence of hemorrhagic complications (p = 0.12). Before the second procedure but not before the initial operation, 4 (12%) of the 33 patients had elevated PT. The findings suggest that the value of preoperative PT testing is limited in patients in whom a normal history can be ascertained. Close postoperative PT control is necessary in every neurosurgical patient, and better tests need to be developed to identify patients who are prone to hemorrhagic complications.
Temple, Derry; Denis, Romain; Walsh, Marianne C; Dicker, Patrick; Byrne, Annette T
2015-02-01
To evaluate the accuracy of the most commonly used anthropometric-based equations in the estimation of percentage body fat (%BF) in both normal-weight and overweight women using air-displacement plethysmography (ADP) as the criterion measure. A comparative study in which the equations of Durnin and Womersley (1974; DW) and Jackson, Pollock and Ward (1980) at three, four and seven sites (JPW₃, JPW₄ and JPW₇) were validated against ADP in three groups. Group 1 included all participants, group 2 included participants with a BMI <25·0 kg/m² and group 3 included participants with a BMI ≥25·0 kg/m². Human Performance Laboratory, Institute for Sport and Health, University College Dublin, Republic of Ireland. Forty-three female participants aged between 18 and 55 years. In all three groups, the %BF values estimated from the DW equation were closer to the criterion measure (i.e. ADP) than those estimated from the other equations. Of the three JPW equations, JPW₃ provided the most accurate estimation of %BF when compared with ADP in all three groups. In comparison to ADP, these findings suggest that the DW equation is the most accurate anthropometric method for the estimation of %BF in both normal-weight and overweight females.
Verification and Enhancement of VIIRS Day-Night Band Power Outage Detection Product
NASA Astrophysics Data System (ADS)
Burke, A.; Schultz, L. A.; Omitaomu, O.; Molthan, A.; Cole, T.; Griffin, R.
2017-12-01
The NASA SPoRT (Short-term Prediction Research and Transition) Center has collaborated with scientists at NASA Goddard Space Flight Center to create a power outage detection product from radiance data obtained by the VIIRS (Visible Infrared Imaging Radiometer Suite) sensor aboard the Suomi-NPP satellite. This product uses a composite of pre-event radiance values from the VIIRS Day-Night Band to establish a baseline of "normal" nighttime lights for a study area. Then, after a severe weather event or other disaster, post-event images are compared to the composite to generate a percent-of-normal radiance product to identify areas that are experiencing outages and to aid in disaster response and monitor recovery. This project will use ground-truth county-level outage data provided by Oak Ridge National Laboratory (ORNL) in order validate the product and to establish a percent-of-normal threshold for identifying power outages. Once a threshold is found, ORNL's LandScan Global population data will be combined with the product to estimate how many electrical customers are being affected by power outages after a disaster. Two case studies will be explored to examine power outage recovery after severe weather events, including Hurricane Matthew from 2016 and the Washington D.C. Derecho event of 2012.
Barnett, David; Whitby, Liam; Wong, John; Louzao, Raul; Reilly, John T; Denny, Thomas N
2012-03-01
The aim of clinical laboratories is to produce accurate and reproducible results to enable effective and reliable clinical practice and patient management. The standard approach is to use both internal quality control (IQC) and external quality assessment (EQA). IQC serves, in many instances, as a "go, no go" tool to provide real time assurance that instruments and reagent or test systems are performing within defined specifications. EQA however, takes a snapshot at a specific point in time of the full testing process, results are compared to other laboratories performing similar testing but inevitably has some built in delay from sample issue to performance data review. In addition, if IQC or EQA identify areas of concern it can be difficult to determine the exact nature of the problem. In an attempt to address this problem, we have developed an instant QA panel that we have termed VERIQAS™, specifically for CD4(+) T lymphocyte counting, and have undertaken a "proof of principle" pilot study to examine how the use of VERIQAS™ could result in improvement of laboratory performance. In addition, we have examined how this approach could be used as a training and education tool (in a domestic/international setting) and potentially be of value in instrument validation/switch studies (a switch study being defined as a laboratory changing from one method/instrument to a new method/instrument with the VERIQAS™ panel being used as an adjunct to their standard switch study protocol). The basic panel consists of 20 stabilized samples, with predefined CD4(+) T lymphocyte counts, that span low clinically relevant to normal counts, including some blinded replicates (singlet up to quadruplicate combinations). The CD4(+) T lymphocyte target values for each specimen is defined as the trimmed mean ± 2 trimmed standard deviations, where the trimmed values are derived from the CD4(+) T lymphocyte counts reported by the participating centers (~780 laboratories) that receive each UK NEQAS for Leucocyte Immunophenotyping send out. Results for the VERIQAS™ panel were returned online, via a specially designed website, and the participant was provided with an immediate assessment (pass or fail). To date, the panel has been preliminary trialed by eight laboratories to (i) assess pre-EQA qualification (two laboratories); (ii) address performance issues (two laboratories); or (iii) validate new instruments or techniques (four laboratories). Interestingly, even in this pilot study, the panel has been instrumental in identifying specific technical problems in laboratories with EQA performance issues as well as confirming that implementation of new techniques or instruments have been successful. We report here a new and novel "proof of principle" pilot study to quality assessment, that we have termed VERIQAS™, designed to provide instant feedback on performance. Participating laboratories receive 20 "blinded" samples that are in singlet up to quadruplicate combinations. Once a centre reports its results via a website, immediate feedback is provided to both the participant and the EQA organizers, enabling, if required, the initiation of targeted remedial action. We have also shown that this approach has the potential to be used as a tool for prequalification, troubleshooting, training and instrument verification. Pilot phase field trials with VERIQAS™ have shown that the panel can highlight laboratory performance problems, such as suboptimal instrument set up, pipetting and gating strategies, in a rapid and efficient manner. VERIQAS™ will now be introduced, where appropriate, as a second phase study within UK NEQAS for Leucocyte Immunophenotyping to assist those laboratories that have performance issues and also made available to laboratories for training and education of staff and instrument validation studies. Copyright © 2011 International Clinical Cytometry Society.
Univariate normalization of bispectrum using Hölder's inequality.
Shahbazi, Forooz; Ewald, Arne; Nolte, Guido
2014-08-15
Considering that many biological systems including the brain are complex non-linear systems, suitable methods capable of detecting these non-linearities are required to study the dynamical properties of these systems. One of these tools is the third order cummulant or cross-bispectrum, which is a measure of interfrequency interactions between three signals. For convenient interpretation, interaction measures are most commonly normalized to be independent of constant scales of the signals such that its absolute values are bounded by one, with this limit reflecting perfect coupling. Although many different normalization factors for cross-bispectra were suggested in the literature these either do not lead to bounded measures or are themselves dependent on the coupling and not only on the scale of the signals. In this paper we suggest a normalization factor which is univariate, i.e., dependent only on the amplitude of each signal and not on the interactions between signals. Using a generalization of Hölder's inequality it is proven that the absolute value of this univariate bicoherence is bounded by zero and one. We compared three widely used normalizations to the univariate normalization concerning the significance of bicoherence values gained from resampling tests. Bicoherence values are calculated from real EEG data recorded in an eyes closed experiment from 10 subjects. The results show slightly more significant values for the univariate normalization but in general, the differences are very small or even vanishing in some subjects. Therefore, we conclude that the normalization factor does not play an important role in the bicoherence values with regard to statistical power, although a univariate normalization is the only normalization factor which fulfills all the required conditions of a proper normalization. Copyright © 2014 Elsevier B.V. All rights reserved.
A replacement for islet equivalents with improved reliability and validity.
Huang, Han-Hung; Ramachandran, Karthik; Stehno-Bittel, Lisa
2013-10-01
Islet equivalent (IE), the standard estimate of isolated islet volume, is an essential measure to determine the amount of transplanted islet tissue in the clinic and is used in research laboratories to normalize results, yet it is based on the false assumption that all islets are spherical. Here, we developed and tested a new easy-to-use method to quantify islet volume with greater accuracy. Isolated rat islets were dissociated into single cells, and the total cell number per islet was determined by using computer-assisted cytometry. Based on the cell number per islet, we created a regression model to convert islet diameter to cell number with a high R2 value (0.8) and good validity and reliability with the same model applicable to young and old rats and males or females. Conventional IE measurements overestimated the tissue volume of islets. To compare results obtained using IE or our new method, we compared Glut2 protein levels determined by Western Blot and proinsulin content via ELISA between small (diameter≤100 μm) and large (diameter≥200 μm) islets. When normalized by IE, large islets showed significantly lower Glut2 level and proinsulin content. However, when normalized by cell number, large and small islets had no difference in Glut2 levels, but large islets contained more proinsulin. In conclusion, normalizing islet volume by IE overestimated the tissue volume, which may lead to erroneous results. Normalizing by cell number is a more accurate method to quantify tissue amounts used in islet transplantation and research.
Birk, Ruth; Heifetz, Eliyahu M
2018-04-28
Biochemical laboratory values are an essential tool in medical diagnosis, treatment, and follow-up; however, they are known to vary between populations. Establishment of ethnicity-adjusted reference values is recommended by health organizations. To investigate the ethnicity element in biochemical lab values studying women of different ethnic groups. Biochemical lab values (n = 27) of 503 adult Israeli women of three ethnicities (Jewish Ashkenazi, Jewish Sephardic, and Bedouin Arab) attending a single medical center were analyzed. Biochemical data were extracted from medical center records. Ethnic differences of laboratory biochemicals were studied using ANCOVA to analyze the center of the distribution as well as quartile regression analysis to analyze the upper and lower limits, both done with an adjustment for age. Significant ethnic differences were found in almost half (n = 12) of the biochemical laboratory tests. Ashkenazi Jews exhibited significantly higher mean values compared to Bedouins in most of the biochemical tests, including albumin, alkaline phosphatase, calcium, cholesterol, cholesterol LDL and HDL, cholesterol LDL calc., folic acid, globulin, and iron saturation, while the Bedouins exhibited the highest mean values in the creatinine and triglycerides. For most of these tests, Sephardic Jews exhibited biochemical mean levels in between the two other groups. Compared to Ashkenazi Jews, Sephardic Jews had a significant shift to lower values in cholesterol LDL. Ethnic subpopulations have distinct distributions in biochemical laboratory test values, which should be taken into consideration in medical practice enabling precision medicine.
Björkström, S; Goldie, I F
1982-06-01
The hardness of bone is its property of withstanding the impact of a penetrating agent. It has been found that articular degenerative changes in, for example, the tibia (knee) are combined with a decrease in the hardness of the subchondral bone. In this investigation the hardness of subchondral bone in chondromalacia and osteoarthrosis of the patella has been analysed and compared with normal subchondral bone. Using an indentation method originally described by Brinell the hardness of the subchondral bone was evaluated in 7 normal patellae, in 20 with chondromalacia and in 33 with osteoarthrosis. A microscopic and microradiographic study of the subchondral bone was carried out simultaneously. Hardness was lowest in the normal material. The mean hardness value beneath the degenerated cartilage differed only slightly from that of the normal material, but the variation of values was increased. The hardness in bone in the chondromalacia area was lower than the hardness in bone covered by surrounding normal cartilage. The mean hardness value in bone beneath normal parts of cartilage in specimens with chondromalacia was higher than the mean hardness value of the normal material. In the microscopic and microradiographic examination it became evident that there was a relationship between trabecular structure and subchondral bone hardness; high values: coarse and solid structure; low values: slender and less regular structure.
A field assessment of long-term laboratory sediment toxicity tests with the amphipod Hyalella azteca
Ingersoll, Christopher G.; Wang, Ning; Hayward, Jeannie M. R.; Jones, John R.; Jones, Susan B.; Ireland, D. Scott
2005-01-01
Response of the amphipod Hyalella azteca exposed to contaminated sediments for 10 to 42 d in laboratory toxicity tests was compared to responses observed in controlled three-month invertebrate colonization exposures conducted in a pond. Sediments evaluated included a sediment spiked with dichlorodiphenyldichloroethane (DDD) or dilutions of a field sediment collected from the Grand Calumet River (GCR) in Indiana (USA) (contaminated with organic compounds and metals). Consistent effects were observed at the highest exposure concentrations (400 ??g DDD/goc [DDD concentrations normalized to grams of organic carbon (goc) in sedimentl or 4% GCR sediment) on survival, length, and reproduction of amphipods in the laboratory and on abundance of invertebrates colonizing sediments in the field. Effect concentrations for DDD observed for 10-d length and 42-d reproduction of amphipods (e.g., chronic value [ChV] of 66 ??g DDD/goc and 25% inhibition concentration [IC25] of 68 ??g DDD/goc for reproduction) were similar to the lowest effect concentrations for DDD measured on invertebrates colonizing sediment the field. Effect concentrations for GCR sediment on 28-d survival and length and 42-d reproduction and length of amphipods (i.e., ChVs of 0.20-0.66% GCR sediment) provided more conservative effect concentrations compared to 10-d survival or length of amphipods in the laboratory or the response of invertebrates colonizing sediment in the field (e.g., ChVs of 2.2% GCR sediment). Results of this study indicate that use of chronic laboratory toxicity tests with H. azteca and benthic colonization studies should be used to provide conservative estimates of impacts on benthic communities exposed to contaminated sediments. Bioaccumulation of DDD by oligochaetes colonizing the DDD-spiked sediment was similar to results of laboratory sediment tests previously conducted with the oligochaete Lumbriculus variegates, confirming that laboratory exposures can be used to estimate bioaccumulation by oligochaetes exposed in the field. ?? 2005 SETAC.
Proficiency Tests for Environmental Radioactivity Measurement Organized by an Accredited Laboratory
NASA Astrophysics Data System (ADS)
Aubert, Cédric; Osmond, Mélanie
2008-08-01
For 40 years, STEME (Environmental Sample Processing and Metrology Department) organized international proficiency testing (PT) exercises formerly for WHO (World Health Organization) and EC (European Community) and currently for ASN (French Nuclear Safety Authority). Five PT exercises are organized each year for the measurement of radionuclides (alpha, beta and gamma) in different matrixes (water, soil, biological and air samples) at environmental levels. ASN can deliver a French ministerial agreement to participate on environmental radioactivity measurements French network for laboratories asking it [1]. Since 2006, November, STEME is the first French entity obtaining a COFRAC (French Committee of Accreditation) accreditation as "Interlaboratory Comparisons" for the organization of proficiency tests for environmental radioactivity measurement according to standard International Standard Organization (ISO) 17025 and guide ISO 43-1. STEME has in charge to find, as far as possible, real sample or to create, by radionuclide adding, an adapted sample. STEME realizes the sampling, the samples preparation and the dispatching. STEME is also accredited according to Standard 17025 for radioactivity measurements in environmental samples and determines homogeneity, stability and reference values. After the reception of participating laboratories results, STEME executes statistical treatments in order to verify the normal distribution, to eliminate outliers and to evaluate laboratories performance. Laboratories participate with several objectives, to obtain French agreement, to prove the quality of their analytical performance in regards to standard 17025 or to validate new methods or latest developments. For 2 years, in addition to usual PT exercises, new PT about alpha or beta measurement in air filters, radioactive iodine in carbon cartridges or measurement of environmental dosimeters are organized. These PT exercises help laboratories to improve radioactive measurements and to rectify old mistakes. The PT exercises organized by STEME are becoming essential for French and some European laboratories working in radioactive measurements. The STEME organization, in respect of accreditation references, is presented.
Proficiency Tests for Environmental Radioactivity Measurement Organized by an Accredited Laboratory
DOE Office of Scientific and Technical Information (OSTI.GOV)
Aubert, Cedric; Osmond, Melanie
2008-08-14
For 40 years, STEME (Environmental Sample Processing and Metrology Department) organized international proficiency testing (PT) exercises formerly for WHO (World Health Organization) and EC (European Community) and currently for ASN (French Nuclear Safety Authority). Five PT exercises are organized each year for the measurement of radionuclides (alpha, beta and gamma) in different matrixes (water, soil, biological and air samples) at environmental levels. ASN can deliver a French ministerial agreement to participate on environmental radioactivity measurements French network for laboratories asking it. Since 2006, November, STEME is the first French entity obtaining a COFRAC (French Committee of Accreditation) accreditation as 'Interlaboratorymore » Comparisons' for the organization of proficiency tests for environmental radioactivity measurement according to standard International Standard Organization (ISO) 17025 and guide ISO 43-1. STEME has in charge to find, as far as possible, real sample or to create, by radionuclide adding, an adapted sample. STEME realizes the sampling, the samples preparation and the dispatching. STEME is also accredited according to Standard 17025 for radioactivity measurements in environmental samples and determines homogeneity, stability and reference values. After the reception of participating laboratories results, STEME executes statistical treatments in order to verify the normal distribution, to eliminate outliers and to evaluate laboratories performance.Laboratories participate with several objectives, to obtain French agreement, to prove the quality of their analytical performance in regards to standard 17025 or to validate new methods or latest developments. For 2 years, in addition to usual PT exercises, new PT about alpha or beta measurement in air filters, radioactive iodine in carbon cartridges or measurement of environmental dosimeters are organized. These PT exercises help laboratories to improve radioactive measurements and to rectify old mistakes. The PT exercises organized by STEME are becoming essential for French and some European laboratories working in radioactive measurements.The STEME organization, in respect of accreditation references, is presented.« less
Clinical Features of Lysosomal Acid Lipase Deficiency.
Burton, Barbara K; Deegan, Patrick B; Enns, Gregory M; Guardamagna, Ornella; Horslen, Simon; Hovingh, Gerard K; Lobritto, Steve J; Malinova, Vera; McLin, Valerie A; Raiman, Julian; Di Rocco, Maja; Santra, Saikat; Sharma, Reena; Sykut-Cegielska, Jolanta; Whitley, Chester B; Eckert, Stephen; Valayannopoulos, Vassili; Quinn, Anthony G
2015-12-01
The aim of this study was to characterize key clinical manifestations of lysosomal acid lipase deficiency (LAL D) in children and adults. Investigators reviewed medical records of LAL D patients ages ≥5 years, extracted historical data, and obtained prospective laboratory and imaging data on living patients to develop a longitudinal dataset. A total of 49 patients were enrolled; 48 had confirmed LAL D. Mean age at first disease-related abnormality was 9.0 years (range 0-42); mean age at diagnosis was 15.2 years (range 1-46). Twenty-nine (60%) were male patients, and 27 (56%) were <20 years of age at the time of consent/assent. Serum transaminases were elevated in most patients with 458 of 499 (92%) of alanine aminotransferase values and 265 of 448 (59%) of aspartate aminotransferase values above the upper limit of normal. Most patients had elevated low-density lipoprotein (64% patients) and total cholesterol (63%) at baseline despite most being on lipid-lowering therapies, and 44% had high-density lipoprotein levels below the lower limit of normal. More than half of the patients with liver biopsies (n = 31, mean age 13 years) had documented evidence of steatosis (87%) and/or fibrosis (52%). Imaging assessments revealed that the median liver volume was ∼1.15 multiples of normal (MN) and median spleen volume was ∼2.2 MN. Six (13%) patients had undergone a liver transplant (ages 9-43.5 years). This study provides the largest longitudinal case review of patients with LAL D and confirms that LAL D is predominantly a pediatric disease causing early and progressive hepatic dysfunction associated with dyslipidemia that often leads to liver failure and transplantation.
10 CFR 26.169 - Reporting Results.
Code of Federal Regulations, 2012 CFR
2012-01-01
... request. The laboratory shall routinely provide quantitative values for confirmatory opiate test results... requested quantitative values for the test result. (3) For a specimen that has an adulterated or substituted... of the standard curve, the laboratory may report to the MRO that the quantitative value “exceeds the...
10 CFR 26.169 - Reporting Results.
Code of Federal Regulations, 2013 CFR
2013-01-01
... request. The laboratory shall routinely provide quantitative values for confirmatory opiate test results... requested quantitative values for the test result. (3) For a specimen that has an adulterated or substituted... of the standard curve, the laboratory may report to the MRO that the quantitative value “exceeds the...
10 CFR 26.169 - Reporting Results.
Code of Federal Regulations, 2010 CFR
2010-01-01
... request. The laboratory shall routinely provide quantitative values for confirmatory opiate test results... requested quantitative values for the test result. (3) For a specimen that has an adulterated or substituted... of the standard curve, the laboratory may report to the MRO that the quantitative value “exceeds the...
10 CFR 26.169 - Reporting Results.
Code of Federal Regulations, 2011 CFR
2011-01-01
... request. The laboratory shall routinely provide quantitative values for confirmatory opiate test results... requested quantitative values for the test result. (3) For a specimen that has an adulterated or substituted... of the standard curve, the laboratory may report to the MRO that the quantitative value “exceeds the...
10 CFR 26.169 - Reporting Results.
Code of Federal Regulations, 2014 CFR
2014-01-01
... request. The laboratory shall routinely provide quantitative values for confirmatory opiate test results... requested quantitative values for the test result. (3) For a specimen that has an adulterated or substituted... of the standard curve, the laboratory may report to the MRO that the quantitative value “exceeds the...
Bioethics in the Laboratory: Synthesis and Interactivity.
ERIC Educational Resources Information Center
Murray, Kevin J.
1999-01-01
Describes the implementation of a bioethics laboratory exercise that incorporates a variety of instructional strategies. In the activity, General Biology students consider relevant and interesting topics of bioethical importance and prepare classroom presentations on the different viewpoints normally attendant to ethical topics. Includes an…
19 CFR 351.405 - Calculation of normal value based on constructed value.
Code of Federal Regulations, 2010 CFR
2010-04-01
... value. 351.405 Section 351.405 Customs Duties INTERNATIONAL TRADE ADMINISTRATION, DEPARTMENT OF COMMERCE... constructed value as the basis for normal value where: neither the home market nor a third country market is... a fictitious market are disregarded; no contemporaneous sales of comparable merchandise are...
Nagata, Kohei; Kilgore, Brian D.; Beeler, Nicholas M.; Nakatani, Masao
2014-01-01
During localized slip of a laboratory fault we simultaneously measure the contact area and the dynamic fault normal elastic stiffness. One objective is to determine conditions where stiffness may be used to infer changes in area of contact during sliding on nontransparent fault surfaces. Slip speeds between 0.01 and 10 µm/s and normal stresses between 1 and 2.5 MPa were imposed during velocity step, normal stress step, and slide-hold-slide tests. Stiffness and contact area have a linear interdependence during rate stepping tests and during the hold portion of slide-hold-slide tests. So long as linearity holds, measured fault stiffness can be used on nontransparent materials to infer changes in contact area. However, there are conditions where relations between contact area and stiffness are nonlinear and nonunique. A second objective is to make comparisons between the laboratory- and field-measured changes in fault properties. Time-dependent changes in fault zone normal stiffness made in stress relaxation tests imply postseismic wave speed changes on the order of 0.3% to 0.8% per year in the two or more years following an earthquake; these are smaller than postseismic increases seen within natural damage zones. Based on scaling of the experimental observations, natural postseismic fault normal contraction could be accommodated within a few decimeter wide fault core. Changes in the stiffness of laboratory shear zones exceed 10% per decade and might be detectable in the field postseismically.
NASA Technical Reports Server (NTRS)
Schuster, Burton G.; Lazrus, Allan L.; Fernald, Frederick G.; Sedlacek, William; Guthals, Paul
1973-01-01
Collections of particulates on both Los Alamos Scientific Laboratory (LASL) and National Center for Atmospheric Research (NCAR) filter systems were made from an RB 57F aircraft flown at one tropospheric and six stratospheric altitudes over the Boulder, Colorado, area. This daytime flight was spanned by lidar returns on evenings before and after the flight. Scanning electron microscope examination of the LASL filters showed no evidence of solid particulates greater than 2 micrometers (the instrumental resolving power). Quantitative analysis of the NCAR filters yielded chemical composition and mass. The mass values were normalized to the total air flow through the filters to yield mass mixing ratios at the various altitudes. The lidar returns, normalized to molecular densities obtained from sonde data, were put in the form of particulate scattering divided by molecular scattering, i. e., an optical mixing ratio. A plot of the optical mixing ratio versus mass mixing ratio, in the stratosphere, yielded linear relationship, for five of the six data points, going through the origin.
Transcript and protein environmental biomarkers in fish--a review.
Tom, Moshe; Auslander, Meirav
2005-04-01
The levels of contaminant-affected gene products (transcripts and proteins) are increasingly utilized as environmental biomarkers, and their appropriate implementation as diagnostic tools is discussed. The required characteristics of a gene product biomarker are accurate evaluation using properly normalized absolute units, aiming at long-term comparability of biomarker levels over a wide geographical range and among many laboratories. Quantitative RT-PCR and competitive ELISA are suggested as preferred evaluation methods for transcript and protein, respectively. Constitutively expressed RNAs or proteins which are part of the examined homogenate are suggested as normalizing agents, compensating for variable processing efficiency. Essential characterization of expression patterns is suggested, providing reference values to be compared to the monitored levels. This comparison would enable estimation of the intensity of biological effects of contaminants. Contaminant-independent reference expression patterns should include natural fluctuations of the biomarker level. Contaminant-dependent patterns should include dose response to model contaminants chronically administered in two environmentally-realistic routes, reaching extreme sub-lethal affected levels. Recent studies using fish as environmental sentinel species, applying gene products as environmental biomarkers, and implementing at least part of the depicted methodologies are reviewed.
Canalejo, K; Galassi, N; Riera, N; Bengió, R; Aixalá, M
2001-01-01
The expansion of paroxysmal nocturnal hemoglobinuria (PHN) clone was evaluated in a patient with aplastic anemia (AA) of 18 years of evolution during an hemolytic crisis. On day 0, Ham and Sucrosa tests were positive and hematological parameters were altered. Low hemoglobin (Hb) levels and erythrocyte and leukocyte counts were found and continued decreasing on days 7 and 24 (last day of study). High LDH levels, indirect bilirubin and reticulocyte counts were detected throughout. We evaluated CD55 and CD59 on erythrocytes by flow cytometry. Our results showed low CD55 expression with respect to the normal pattern. Since day 0, CD59 staining detected two red cell populations: PNH I (48%), cells with positive fluorescence similar to normal and PNH III (52%), negative cells (PNH clone). These negative cells increased, reaching 70% on day 24. Other membrane anchored leukocyte proteins were also absent (CD14) or decreased (CD16). We found a good correlation between clinical observations, evolution of the laboratory values and expansion of the PNH clone.
GPS FOM Chimney Analysis using Generalized Extreme Value Distribution
NASA Technical Reports Server (NTRS)
Ott, Rick; Frisbee, Joe; Saha, Kanan
2004-01-01
Many a time an objective of a statistical analysis is to estimate a limit value like 3-sigma 95% confidence upper limit from a data sample. The generalized Extreme Value Distribution method can be profitably employed in many situations for such an estimate. . .. It is well known that according to the Central Limit theorem the mean value of a large data set is normally distributed irrespective of the distribution of the data from which the mean value is derived. In a somewhat similar fashion it is observed that many times the extreme value of a data set has a distribution that can be formulated with a Generalized Distribution. In space shuttle entry with 3-string GPS navigation the Figure Of Merit (FOM) value gives a measure of GPS navigated state accuracy. A GPS navigated state with FOM of 6 or higher is deemed unacceptable and is said to form a FOM 6 or higher chimney. A FOM chimney is a period of time during which the FOM value stays higher than 5. A longer period of FOM of value 6 or higher causes navigated state to accumulate more error for a lack of state update. For an acceptable landing it is imperative that the state error remains low and hence at low altitude during entry GPS data of FOM greater than 5 must not last more than 138 seconds. I To test the GPS performAnce many entry test cases were simulated at the Avionics Development Laboratory. Only high value FoM chimneys are consequential. The extreme value statistical technique is applied to analyze high value FOM chimneys. The Maximum likelihood method is used to determine parameters that characterize the GEV distribution, and then the limit value statistics are estimated.
Thouand, Gérald; Durand, Marie-José; Maul, Armand; Gancet, Christian; Blok, Han
2011-01-01
The European REACH Regulation (Registration, Evaluation, Authorization of CHemical substances) implies, among other things, the evaluation of the biodegradability of chemical substances produced by industry. A large set of test methods is available including detailed information on the appropriate conditions for testing. However, the inoculum used for these tests constitutes a “black box.” If biodegradation is achievable from the growth of a small group of specific microbial species with the substance as the only carbon source, the result of the test depends largely on the cell density of this group at “time zero.” If these species are relatively rare in an inoculum that is normally used, the likelihood of inoculating a test with sufficient specific cells becomes a matter of probability. Normally this probability increases with total cell density and with the diversity of species in the inoculum. Furthermore the history of the inoculum, e.g., a possible pre-exposure to the test substance or similar substances will have a significant influence on the probability. A high probability can be expected for substances that are widely used and regularly released into the environment, whereas a low probability can be expected for new xenobiotic substances that have not yet been released into the environment. Be that as it may, once the inoculum sample contains sufficient specific degraders, the performance of the biodegradation will follow a typical S shaped growth curve which depends on the specific growth rate under laboratory conditions, the so called F/M ratio (ratio between food and biomass) and the more or less toxic recalcitrant, but possible, metabolites. Normally regulators require the evaluation of the growth curve using a simple approach such as half-time. Unfortunately probability and biodegradation half-time are very often confused. As the half-time values reflect laboratory conditions which are quite different from environmental conditions (after a substance is released), these values should not be used to quantify and predict environmental behavior. The probability value could be of much greater benefit for predictions under realistic conditions. The main issue in the evaluation of probability is that the result is not based on a single inoculum from an environmental sample, but on a variety of samples. These samples can be representative of regional or local areas, climate regions, water types, and history, e.g., pristine or polluted. The above concept has provided us with a new approach, namely “Probabio.” With this approach, persistence is not only regarded as a simple intrinsic property of a substance, but also as the capability of various environmental samples to degrade a substance under realistic exposure conditions and F/M ratio. PMID:21863143
Infectivity of Chordodes nobilii larvae (Gordiida: Nematomorpha).
Achiorno, Cecilia L; de Villalobos, L Cristina; Ferrari, Lucrecia
2017-03-01
The gordiids are freshwater representatives of the parasite phylum Nematomorpha that function as a link between aquatic and terrestrial ecosystems. In recent years, different ecotoxicologic studies have been made with the South-American gordiid species, Chordodes nobilii, that have demonstrated the capacity of this group to act as a bioindicator of contamination. Despite the Gordiida’s ecologic relevance, further studies are still needed to elucidate different aspects of the biology of the class, and among those, the infective capacity, a parameter that can be evaluated by the infection index mean abundance (IIMA). A knowledge of the intrinsic variability in the infective capacity of C. nobilii would warrant priority in order to establish, the range of acceptable responses for normal or standard conditions in the laboratory, and, to compare the criteria among different assays. The objective of this study was to establish a baseline value for the infective capacity for C. nobilii larvae, under controlled laboratory conditions, by employing the IIMA as the evaluation parameter. To that end, we analyzed the infective capacity of C. nobilii larvae that had hatched from different strings of eggs laid in the laboratory by a total of 12 females. The C. nobilii adults were collected from streams within the Argentina Sauce Grande basin, between 2006 and 2009. Once in the laboratory, after mating, the females were placed in individual containers for oviposition. The egg strings obtained from each female were cut in 3 mm long segments; and when free larvae were observed, the segments (N= 90) were placed together with 30 Aedes aegypti larvae for evaluation of the gordiids’ infective capacity. After 72 h, the mosquito larvae were observed by microscopy in order to quantify the C. nobilii larvae in body cavities. The IIMAs were calculated as the total number of C. nobilii larvae present divided by total number of A. aegypti larvae examined. For analysis of the IIMAs obtained, the data were grouped according to the female who made the original ovoposition. Our results enabled the corroboration of an ample range of responses in the infective capacity of this species, a characteristic that would normally be linked to the progenitors originating the hatch. Because this relationship prevents the establishment of a baseline for making comparisons among assays with gordiids, through the IIMA as a response parameter, we recommend expressing the IIMA values in each assay relative to their respective controls. These findings also provide evidence for the greater success in infections by certain members of the progeny over others. Finally, on the basis of the results obtained from this study, we stress the relevance of the use of the IIMA as a decisive aspect to be considered in different studies on the biology of Gordiida.
Afrifa, Justice; Gyekye, Seth A; Owiredu, William K B A; Ephraim, Richard K D; Essien-Baidoo, Samuel; Amoah, Samuel; Simpong, David L; Arthur, Aaron R
2015-01-01
Sigma metrics provide a uniquely defined scale with which we can assess the performance of a laboratory. The objective of this study was to assess the internal quality control (QC) in the clinical chemistry laboratory of the University of Cape Cost Hospital (UCC) using the six sigma metrics application. We used commercial control serum [normal (L1) and pathological (L2)] for validation of quality control. Metabolites (glucose, urea, and creatinine), lipids [triglycerides (TG), total cholesterol, high-density lipoprotein cholesterol (HDL-C)], enzymes [alkaline phosphatase (ALP), alanine aminotransferase (AST)], electrolytes (sodium, potassium, chloride) and total protein were assessed. Between-day imprecision (CVs), inaccuracy (Bias) and sigma values were calculated for each control level. Apart from sodium (2.40%, 3.83%), chloride (2.52% and 2.51%) for both L1 and L2 respectively, and glucose (4.82%), cholesterol (4.86%) for L2, CVs for all other parameters (both L1 and L2) were >5%. Four parameters (HDL-C, urea, creatinine and potassium) achieved sigma levels >1 for both controls. Chloride and sodium achieved sigma levels >1 for L1 but <1 for L2. In contrast, cholesterol, total protein and AST achieved sigma levels <1 for L1 but >1 for L2. Glucose and ALP achieved a sigma level >1 for both control levels whereas TG achieved a sigma level >2 for both control levels. Unsatisfactory sigma levels (<3) where achieved for all parameters using both control levels, this shows instability and low consistency of results. There is the need for detailed assessment of the analytical procedures and the strengthening of the laboratory control systems in order to achieve effective six sigma levels for the laboratory.
Afrifa, Justice; Gyekye, Seth A.; Owiredu, William K. B. A.; Ephraim, Richard K. D.; Essien-Baidoo, Samuel; Amoah, Samuel; Simpong, David L.; Arthur, Aaron R.
2015-01-01
Background: Sigma metrics provide a uniquely defined scale with which we can assess the performance of a laboratory. The objective of this study was to assess the internal quality control (QC) in the clinical chemistry laboratory of the University of Cape Cost Hospital (UCC) using the six sigma metrics application. Materials and Methods: We used commercial control serum [normal (L1) and pathological (L2)] for validation of quality control. Metabolites (glucose, urea, and creatinine), lipids [triglycerides (TG), total cholesterol, high-density lipoprotein cholesterol (HDL-C)], enzymes [alkaline phosphatase (ALP), alanine aminotransferase (AST)], electrolytes (sodium, potassium, chloride) and total protein were assessed. Between-day imprecision (CVs), inaccuracy (Bias) and sigma values were calculated for each control level. Results: Apart from sodium (2.40%, 3.83%), chloride (2.52% and 2.51%) for both L1 and L2 respectively, and glucose (4.82%), cholesterol (4.86%) for L2, CVs for all other parameters (both L1 and L2) were >5%. Four parameters (HDL-C, urea, creatinine and potassium) achieved sigma levels >1 for both controls. Chloride and sodium achieved sigma levels >1 for L1 but <1 for L2. In contrast, cholesterol, total protein and AST achieved sigma levels <1 for L1 but >1 for L2. Glucose and ALP achieved a sigma level >1 for both control levels whereas TG achieved a sigma level >2 for both control levels. Conclusion: Unsatisfactory sigma levels (<3) where achieved for all parameters using both control levels, this shows instability and low consistency of results. There is the need for detailed assessment of the analytical procedures and the strengthening of the laboratory control systems in order to achieve effective six sigma levels for the laboratory. PMID:25657495
NASA Astrophysics Data System (ADS)
Ryan, K. L.; Marone, C.
2015-12-01
During the seismic cycle, faults repeatedly fail and regain strength. The gradual strength recovery is often referred to as frictional healing, and existing works suggest that healing can play an important role in determining the mode of fault slip ranging from dynamic rupture to slow earthquakes. Laboratory studies can play an important role in identifying the processes of frictional healing and their evolution with shear strain during the seismic cycle. These studies also provide data for laboratory-derived friction constitutive laws, which can improve dynamic earthquake models. Previous work shows that frictional healing varies with shear stress on a fault during the interseismic period. Unfortunately, the micromechanical processes that cause shear stress dependent frictional healing are not well understood and cannot be incorporated into current earthquake models. In fault gouge, frictional healing involves compaction and particle rearrangement within sheared granular layers. Therefore, to address these issues, we investigate the role grain size reduction plays in frictional re-strengthening processes at different levels of shear stress. Sample material was preserved from biaxial deformation experiments on granular Westerly granite. The normal stress was held constant at 25 MPa and we performed several 100 second slide-hold-slide tests in each experiment. We conducted a series of 5 experiments each with a different value of normalized shear stress (ranging from 0 to 1), defined as the ratio of the pre-hold shear stress to the shear stress during the hold. The particle size distribution for each sample was analyzed. In addition, acoustic measurements were recorded throughout our experiments to investigate variations in ultrasonic velocity and signal amplitude that reflect changes in the elastic moduli of the layer. Acoustic monitoring provides information about healing mechanisms and can provide a link between laboratory studies and tectonic fault zones.
Brain, Keith L.; Kay, Jonathan; Shine, Brian
2009-01-01
Background Despite the rarity of pheochromocytoma, the dangers of uncontrolled severe hypertension and the very effective surgical treatment of this condition mean that diagnosis is important. Urinary or plasma catecholamines or catecholamine-derivatives are commonly used to screen for pheochromocytomas prior to imaging. This study investigates whether derived measures obtained from 24-hour urinary metanephrine results, patient age and sex can better predict tumors in populations with a low pre-test probability. Methods This study takes a pragmatic approach by retrospectively studying the outcomes of an unselected population referred for urinary metanephrine testing (1819 patients) to a tertiary hospital laboratory, and investigates the usefulness of some simple derivative measures for detecting pheochromocytoma. Urinary 24-hour excretion of metanephrine, normetanephrine and 3-methoxytyramine were normalized by dividing by an age- and sex- specific reference range. The ability of products of these normalized measures to predict pheochromocytomas was assessed, compared to a gold standard of biopsy-confirmed tumor. Results The normalized product of urinary metanephrine and normetanephrine excretion (nMAD.nNMT) proved to be a highly sensitive (100%) and specific (99.1%) measure yielding a positive predictive value 82%. Receiver-operator characteristic curves were not improved by including the normalized 3-methoxytyramine concentrations in the product. nMAD.nNMT gave higher sensitivity and specificity than either test alone. Conclusion We suggest that nMAD.nNMT is a useful measure for identifying pheochromocytoma in a population with a low pre-test probability. PMID:16990424
Precipitating factors of somnambulism: impact of sleep deprivation and forced arousals.
Pilon, Mathieu; Montplaisir, Jacques; Zadra, Antonio
2008-06-10
Experimental attempts to induce sleepwalking with forced arousals during slow-wave sleep (SWS) have yielded mixed results in children and have not been investigated in adult patients. We hypothesized that the combination of sleep deprivation and external stimulation would increase the probability of inducing somnambulistic episodes in sleepwalkers recorded in the sleep laboratory. The main goal of this study was to assess the effects of forced arousals from auditory stimuli (AS) in adult sleepwalkers and control subjects during normal sleep and following post-sleep deprivation recovery sleep. Ten sleepwalkers and 10 controls were investigated. After a baseline night, participants were presented with AS at predetermined sleep stages either during normal sleep or recovery sleep following 25 hours of sleep deprivation. One week later, the conditions with AS were reversed. No somnambulistic episodes were induced in controls. When compared to the effects of AS during sleepwalkers' normal sleep, the presentation of AS during sleepwalkers' recovery sleep significantly increased their efficacy in experimentally inducing somnambulistic events and a significantly greater proportion of sleepwalkers (100%) experienced at least one induced episode during recovery SWS as compared to normal SWS (30%). There was no significant difference between the mean intensity of AS that induced episodes during sleepwalkers' SWS and the mean intensity of AS that awakened sleepwalkers and controls from SWS. Sleep deprivation and forced arousals during slow-wave sleep can induce somnambulistic episodes in predisposed adults. The results highlight the potential value of this protocol in establishing a video-polysomnographically based diagnosis for sleepwalking.
Behavior of U 3Si 2 Fuel and FeCrAl Cladding under Normal Operating and Accident Reactor Conditions
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gamble, Kyle Allan Lawrence; Hales, Jason Dean; Barani, Tommaso
2016-09-01
As part of the Department of Energy's Nuclear Energy Advanced Modeling and Simulation program, an Accident Tolerant Fuel High Impact Problem was initiated at the beginning of fiscal year 2015 to investigate the behavior of \\usi~fuel and iron-chromium-aluminum (FeCrAl) claddings under normal operating and accident reactor conditions. The High Impact Problem was created in response to the United States Department of Energy's renewed interest in accident tolerant materials after the events that occurred at the Fukushima Daiichi Nuclear Power Plant in 2011. The High Impact Problem is a multinational laboratory and university collaborative research effort between Idaho National Laboratory, Losmore » Alamos National Laboratory, Argonne National Laboratory, and the University of Tennessee, Knoxville. This report primarily focuses on the engineering scale research in fiscal year 2016 with brief summaries of the lower length scale developments in the areas of density functional theory, cluster dynamics, rate theory, and phase field being presented.« less
Na, Min Kyun; Won, Yu Deok; Kim, Choong Hyun; Kim, Jae Min; Cheong, Jin Hwan; Ryu, Je Il; Han, Myung-Hoon
2017-01-01
Hydrocephalus is a frequent complication following subarachnoid hemorrhage. Few studies investigated the association between laboratory parameters and shunt-dependent hydrocephalus. This study aimed to investigate the variations of laboratory parameters after subarachnoid hemorrhage. We also attempted to identify predictive laboratory parameters for shunt-dependent hydrocephalus. Multiple imputation was performed to fill the missing laboratory data using Bayesian methods in SPSS. We used univariate and multivariate Cox regression analyses to calculate hazard ratios for shunt-dependent hydrocephalus based on clinical and laboratory factors. The area under the receiver operating characteristic curve was used to determine the laboratory risk values predicting shunt-dependent hydrocephalus. We included 181 participants with a mean age of 54.4 years. Higher sodium (hazard ratio, 1.53; 95% confidence interval, 1.13-2.07; p = 0.005), lower potassium, and higher glucose levels were associated with higher shunt-dependent hydrocephalus. The receiver operating characteristic curve analysis showed that the areas under the curve of sodium, potassium, and glucose were 0.649 (cutoff value, 142.75 mEq/L), 0.609 (cutoff value, 3.04 mmol/L), and 0.664 (cutoff value, 140.51 mg/dL), respectively. Despite the exploratory nature of this study, we found that higher sodium, lower potassium, and higher glucose levels were predictive values for shunt-dependent hydrocephalus from postoperative day (POD) 1 to POD 12-16 after subarachnoid hemorrhage. Strict correction of electrolyte imbalance seems necessary to reduce shunt-dependent hydrocephalus. Further large studies are warranted to confirm our findings.
Ayazi, Parviz; Mahyar, Abolfazl; Noroozian, Elham; Esmailzadehha, Neda; Barikani, Ameneh
2015-12-01
Accurate and early diagnosis and appropriate treatment of patient with urinary tract infection (UTI) are essential for the prevention or restriction of permanent damage to the kidneys in children. The aim of this study was to compare renal ultrasonography (US) and dimercaptosuccinic acid (DMSA) renal scan in the diagnosis of patients with febrile urinary tract infection. This study involved the medical records of children with febrile urinary tract infection who were admitted to the children's hospital in Qazvin, Iran. Pyelonephritis was diagnosed on the basis of clinical symptoms, laboratory tests and abnormal DMSA renal scans. The criteria for abnormality of renal US were an increase or a decrease in diffuse or focal parenchymal echogenicity, loss of corticomedullary differentiation, kidney position irregularities, parenchymal reduction and increased kidney size. Of the 100 study patients, 23% had an abnormal US and 46% had an abnormal DMSA renal scan. Of the latter patients, 15 had concurrent abnormal US (P value ≤ 0.03, concordance rate: 18%). Renal US had a sensitivity of 32%, specificity of 85%, positive predictive value of 65% and negative predictive value of 60%. Of the 77 patients with normal US, 31 (40.2%) had an abnormal DMSA renal scan. Despite the benefits and accessibility of renal US, its value in the diagnosis of pyelonephritis is limited.
Lee, We-Kang; Su, Yi-An; Song, Tzu-Jiun; Chiu, Yao-Chu; Lin, Ching-Hung
2014-01-01
The Iowa Gambling Task (IGT) developed by Bechara et al. in 1994 is used to diagnose patients with Ventromedial Medial Prefrontal Cortex (VMPFC) lesions, and it has become a landmark in research on decision making. According to Bechara et al., the manipulation of progressive increments of monetary value can normalize the performance of patients with VMPFC lesions; thus, they developed a computerized version of the IGT. However, the empirical results showed that patients' performances did not improve as a result of this manipulation, which suggested that patients with VMPFC lesions performed myopically for future consequences. Using the original version of the IGT, some IGT studies have demonstrated that increments of monetary value significantly influence the performance of normal subjects in the IGT. However, other research has resulted in inconsistent findings. In this study, we used the computerized IGT (1X-IGT) and manipulated the value contrast of progressive increments (i.e., by designing the 10X-IGT, which contained 10 times of progressive increment) to investigate the influence of value contrast on the performance of normal subjects. The resulting empirical observations indicated that the value contrast (1X- vs. 10X-IGT) of the progressive increment had no effect on the performance of normal subjects. This study also provides a discussion of the issue of value in IGT-related studies. Moreover, we found the "prominent deck B phenomenon" in both versions of the IGT, which indicated that the normal subjects were guided mostly by the gain-loss frequency, rather than by the monetary value contrast. In sum, the behavioral performance of normal subjects demonstrated a low correlation with changes in monetary value, even in the 10X-IGT.
Impact of the serum ferritin concentration in liver transplantation.
Wakiya, Taiichi; Sanada, Yukihiro; Urahashi, Taizen; Ihara, Yoshiyuki; Yamada, Naoya; Okada, Noriki; Hirata, Yuta; Hakamada, Kenichi; Yasuda, Yoshikazu; Mizuta, Koichi
2015-11-01
The serum ferritin (SF) concentration is a widely available and objective laboratory parameter. SF is also widely recognized as an acute-phase reactant. The purpose of the present study was to identify the chronological changes in the recipient's SF concentration during liver transplantation (LT) and to clarify factors having an effect on the recipient's intraoperative SF level. In addition, the study retrospectively evaluated the usefulness of measuring SF during LT. Ninety-eight pediatric recipients were retrospectively analyzed. The data were analyzed and compared according to the SF level in the recipient. Patients were classified into 2 groups based on the intraoperative peak SF levels of ≤ 1000 ng/mL (low-SF group) or >1000 ng/mL (high-SF group). The SF value increased dramatically after reperfusion and fell to normal levels within the early postoperative period. The warm ischemia time (WIT) was significantly longer in the high-SF group (47.0 versus 58.5 minutes; P = 0.003). In addition, a significant positive correlation was observed between the peak SF value and WIT (r = 0.35; P < 0.001). There were significant positive correlations between the peak SF value and the donors' preoperative laboratory data, including transaminases, cholinesterase, hemoglobin, transferrin saturation, and SF, of which SF showed the strongest positive correlation (r = 0.74; P < 0.001). The multivariate analysis revealed that WIT and donor's SF level were a significant risk factor for high SF level in the recipient (P = 0.007 and 0.02, respectively). In conclusion, the SF measurement can suggest the degree of ischemia/reperfusion injury (IRI). A high SF level in the donor is associated with the risk of further acute reactions, such as IRI, in the recipient. © 2015 American Association for the Study of Liver Diseases.
Physical modeling of the formation and evolution of seismically active fault zones
Ponomarev, A.V.; Zavyalov, A.D.; Smirnov, V.B.; Lockner, D.A.
1997-01-01
Acoustic emission (AE) in rocks is studied as a model of natural seismicity. A special technique for rock loading has been used to help study the processes that control the development of AE during brittle deformation. This technique allows us to extend to hours fault growth which would normally occur very rapidly. In this way, the period of most intense interaction of acoustic events can be studied in detail. Characteristics of the acoustic regime (AR) include the Gutenberg-Richter b-value, spatial distribution of hypocenters with characteristic fractal (correlation) dimension d, Hurst exponent H, and crack concentration parameter Pc. The fractal structure of AR changes with the onset of the drop in differential stress during sample deformation. The change results from the active interaction of microcracks. This transition of the spatial distribution of AE hypocenters is accompanied by a corresponding change in the temporal correlation of events and in the distribution of event amplitudes as signified by a decrease of b-value. The characteristic structure that develops in the low-energy background AE is similar to the sequence of the strongest microfracture events. When the AR fractal structure develops, the variations of d and b are synchronous and d = 3b. This relation which occurs once the fractal structure is formed only holds for average values of d and b. Time variations of d and b are anticorrelated. The degree of temporal correlation of AR has time variations that are similar to d and b variations. The observed variations in laboratory AE experiments are compared with natural seismicity parameters. The close correspondence between laboratory-scale observations and naturally occurring seismicity suggests a possible new approach for understanding the evolution of complex seismicity patterns in nature. ?? 1997 Elsevier Science B.V. All rights reserved.
Böhlke, J.K.; Mroczkowski, S.J.; Coplen, T.B.
2003-01-01
Despite a rapidly growing literature on analytical methods and field applications of O isotope-ratio measurements of NO3− in environmental studies, there is evidence that the reported data may not be comparable because reference materials with widely varying δ18O values have not been readily available. To address this problem, we prepared large quantities of two nitrate salts with contrasting O isotopic compositions for distribution as reference materials for O isotope-ratio measurements: USGS34 (KNO3) with low δ18O and USGS35 (NaNO3) with high δ18O and ‘mass-independent’ δ17O. The procedure used to produce USGS34 involved equilibration of HNO3 with 18O-depleted meteoric water. Nitric acid equilibration is proposed as a simple method for producing laboratory NO3− reference materials with a range of δ18O values and normal (mass-dependent) 18O:17O:16O variation. Preliminary data indicate that the equilibrium O isotope-fractionation factor (α) between [NO3−] and H2O decreases with increasing temperature from 1.0215 at 22°C to 1.0131 at 100°C. USGS35 was purified from the nitrate ore deposits of the Atacama Desert in Chile and has a high 17O:18O ratio owing to its atmospheric origin. These new reference materials, combined with previously distributed NO3− isotopic reference materials IAEA-N3 (=IAEA-NO-3) and USGS32, can be used to calibrate local laboratory reference materials for determining offset values, scale factors, and mass-independent effects on N and O isotope-ratio measurements in a wide variety of environmental NO3− samples. Preliminary analyses yield the following results (normalized with respect to VSMOW and SLAP, with reproducibilities of ±0.2–0.3‰, 1σ): IAEA-N3 has δ18O = +25.6‰ and δ17O = +13.2‰; USGS32 has δ18O = +25.7‰; USGS34 has δ18O = −27.9‰ and δ17O = −14.8‰; and USGS35 has δ18O = +57.5‰ and δ17O = +51.5‰.
Interlaboratory comparison of fluorocarbons-11, -12, methylchloroform and nitrous oxide measurements
NASA Technical Reports Server (NTRS)
Rasmussen, R. A.; Khalil, M. A. K.
1981-01-01
Measurements conducted by 19 participating laboratories were considered in the reported interlaboratory comparison study. The results show that there is considerable disagreement among laboratories regarding the absolute concentrations of all four trace gases (CCl3F, CCl2F2, H3CCl3, N2O). The magnitude of this disagreement is discussed. Laboratories in Group II showed considerable disagreement among themselves. Their results were scattered within large intervals of concentration. Laboratories in Group I (using common standards) were in excellent (+ or - 5%) agreement among themselves. A systematic disagreement was noted between Groups I and II laboratories. Generally, the mean values of concentrations determined from the measurements of Group II laboratories were lower than the mean values reported by Group I laboratories.
Almedallah, Dana Khaled; Alshamlan, Dana Yousef; Shariff, Erum Mubbashir
2018-01-01
Myoclonus is an abnormal involuntary movement that has been previously reported with administration of high doses of opioids for prolonged periods of time. In this case, however, we report an acute myoclonic reaction and review the literature on the possible causative pathophysiology. We report the case of a 24-year-old woman who was admitted for postdated cesarean section. She started to have abnormal involuntary movements after administration of an epidural anesthesia containing 700 μg of fentanyl with 115 mL (0.5) bupivacaine and 40 mL (2%) lidocaine. Upon examination, the patient was conscious, alert, and oriented. Her vital signs were stable. Her movements can be described as generalized, sudden, involuntary, jerking movements, involving the upper limbs, head, torso as well as the lower limbs. The frequency of these jerks was about every 1-2 min lasting for 10 s. There was no change in level of consciousness during these abnormal movements. The rest of the neurological examination was normal. Laboratory values showed normoglycemia and normal serum biochemistry. A routine electroencephalogram showed no epileptiform activity. Brain imaging was normal. Based on history, examination, and laboratory findings, we made the diagnosis of drug-induced myoclonus, which in this clinical scenario was secondary to fentanyl. We discontinued fentanyl and, gradually, the intensity and frequency of the abnormal movements decreased and disappeared after a few hours. A clear definitive explanation of the acute effect of opioids is still to be reached. It involves an interaction of complex neuroanatomical pathways and neurophysiological receptors. Nonetheless, a unanimous effort is needed to raise awareness about the role of opioids in the development of abnormal movements and their clinical management, to insure that they do not go unnoticed in the clinical scenarios, and to further add more scientific content that could help in reaching an explanatory theory.
Nucleation and triggering of earthquake slip: effect of periodic stresses
Dieterich, J.H.
1987-01-01
Results of stability analyses for spring and slider systems, with state variable constitutive properties, are applied to slip on embedded fault patches. Unstable slip may nucleate only if the slipping patch exceeds some minimum size. Subsequent to the onset of instability the earthquake slip may propagate well beyond the patch. It is proposed that the seismicity of a volume of the earth's crust is determined by the distribution of initial conditions on the population of fault patches that nucleate earthquake slip, and the loading history acting upon the volume. Patches with constitutive properties inferred from laboratory experiments are characterized by an interval of self-driven accelerating slip prior to instability, if initial stress exceeds a minimum threshold. This delayed instability of the patches provides an explanation for the occurrence of aftershocks and foreshocks including decay of earthquake rates by time-1. A population of patches subjected to loading with a periodic component results in periodic variation of the rate of occurrence of instabilities. The change of the rate of seismicity for a sinusoidal load is proportional to the amplitude of the periodic stress component and inversely proportional to both the normal stress acting on the fault patches and the constitutive parameter, A1, that controls the direct velocity dependence of fault slip. Values of A1 representative of laboratory experiments indicate that in a homogeneous crust, correlation of earthquake rates with earth tides should not be detectable at normal stresses in excess of about 8 MPa. Correlation of earthquakes with tides at higher normal stresses can be explained if there exist inhomogeneities that locally amplify the magnitude of the tidal stresses. Such amplification might occur near magma chambers or other soft inclusions in the crust and possibly near the ends of creeping fault segments if the creep or afterslip rates vary in response to tides. Observations of seismicity rate variations associated with seasonal fluctuations of reservoir levels appear to be consistent with the model. ?? 1987.
Customer Satisfaction Assessment at the Pacific Northwest National Laboratory
DOE Office of Scientific and Technical Information (OSTI.GOV)
Anderson, Dale N.; Sours, Mardell L.
2000-03-20
The Pacific Northwest National Laboratory (PNNL) is developing and implementing a customer satisfaction assessment program (CSAP) to assess the quality of research and development provided by the laboratory. We present the customer survey component of the PNNL CSAP. The customer survey questionnaire is composed of 2 major sections, Strategic Value and Project Performance. The Strategic Value section of the questionnaire consists of 5 questions that can be answered with a 5 point Likert scale response. These questions are designed to determine if a project is directly contributing to critical future national needs. The Project Performance section of the questionnaire consistsmore » of 9 questions that can be answered with a 5 point Likert scale response. These questions determine PNNL performance in meeting customer expectations. Many approaches could be used to analyze customer survey data. We present a statistical model that can accurately capture the random behavior of customer survey data. The properties of this statistical model can be used to establish a "gold standard'' or performance expectation for the laboratory, and then assess progress. The gold standard is defined from input from laboratory management --- answers to 4 simple questions, in terms of the information obtained from the CSAP customer survey, define the standard: *What should the average Strategic Value be for the laboratory project portfolio? *What Strategic Value interval should include most of the projects in the laboratory portfolio? *What should average Project Performance be for projects with a Strategic Value of about 2? *What should average Project Performance be for projects with a Strategic Value of about 4? We discuss how to analyze CSAP customer survey data with this model. Our discussion will include "lessons learned" and issues that can invalidate this type of assessment.« less
NASA Astrophysics Data System (ADS)
Shreedharan, S.; Riviere, J.; Marone, C.
2017-12-01
We report on a suite of laboratory friction experiments conducted on saw-cut Westerly Granite surfaces to probe frictional response to step changes in normal stress and loading rate. The experiments are conducted to illuminate the fundamental processes that yield friction rate and state dependence. We quantify the microphysical frictional response of the simulated fault surfaces to normal stress steps, in the range of 1% - 600% step increases and decreases from a nominal baseline normal stress. We measure directly the fault slip rate and account for changes in slip rate with changes in normal stress and complement mechanical data acquisition by continuously probing the faults with ultrasonic pulses. We conduct the experiments at room temperature and humidity conditions in a servo controlled biaxial testing apparatus in the double direct shear configuration. The samples are sheared over a range of velocities, from 0.02 - 100 μm/s. We report observations of a transient shear stress and friction evolution with step increases and decreases in normal stress. Specifically, we show that, at low shear velocities and small increases in normal stress (<5% increase), the shear stress on the fault does not increase instantaneously with the normal stress step while the ultrasonic wave amplitude and normal displacement do. In other words, the shear stress does not follow the load point stiffness curve. At high shear velocities and larger normal stress steps (> 5% increases), the shear stress evolves immediately with normal stress. We show that the excursions in slip rate resulting from the changes in normal stress must be accounted for in order to predict fault strength evolution. Ultrasonic wave amplitudes which first increase immediately in response to normal stress steps, then decrease approximately linearly to a new steady state value, in part due to changes in fault slip rate. Previous descriptions of frictional state evolution during normal stress perturbations have not adequately accounted for the effect of large slip velocity excursions. Here, we attempt to do so by using the measured ultrasonic amplitudes as a proxy for frictional state during transient shear stress evolution. Our work aims to improve understanding of induced and triggered seismicity with focus on simulating static triggering using rate and state friction.
The Idea of a Normal University in the 21st Century
ERIC Educational Resources Information Center
Hayhoe, Ruth; Li, Jun
2010-01-01
The establishment of normal colleges and universities is an important component of building a modern country, which possesses different value ethos with the universities. The emergence of the Ecole Normale Superieure in Paris and the local normal schools has set a new model for teacher education around the world and promoted values and knowledge…
The Synthesis and Chemiluminescence of a Stable 1,2-Dioxetane.
ERIC Educational Resources Information Center
Meijer, E. W.; Wynberg, Hans
1982-01-01
Background information, laboratory procedures, and discussion of results are provided for the synthesis and chemiluminescence of adamantylideneadamantane-1,2-dioxetane (I). Results provided were obtained during a normal junior level organic laboratory course. All intermediates and products were identified using routine spectroscopic analysis.…
Laboratory Indices of Nutritional Status in Pregnancy.
ERIC Educational Resources Information Center
National Academy of Sciences-National Research Council, Washington, DC. Food and Nutrition Board.
This report reviews the current state of knowledge regarding laboratory indices of nutritional and metabolic status during normal pregnancy in order to provide normative data with respect to such indices in healthy pregnant women. The report contains seven chapters: Physiologic Adjustments in General; Hematologic Indices; Electrolytes in Normal…
46 CFR 129.380 - Overcurrent protection.
Code of Federal Regulations, 2014 CFR
2014-10-01
... emergency switch must be provided in each normally ungrounded main supply conductor from a battery. The switch must be accessible from the battery and located as close as practicable to it. (j) No grounded... type and be listed by Underwriters Laboratories (UL) or another independent laboratory recognized by...
46 CFR 129.380 - Overcurrent protection.
Code of Federal Regulations, 2013 CFR
2013-10-01
... emergency switch must be provided in each normally ungrounded main supply conductor from a battery. The switch must be accessible from the battery and located as close as practicable to it. (j) No grounded... type and be listed by Underwriters Laboratories (UL) or another independent laboratory recognized by...
46 CFR 129.380 - Overcurrent protection.
Code of Federal Regulations, 2012 CFR
2012-10-01
... emergency switch must be provided in each normally ungrounded main supply conductor from a battery. The switch must be accessible from the battery and located as close as practicable to it. (j) No grounded... type and be listed by Underwriters Laboratories (UL) or another independent laboratory recognized by...
46 CFR 129.380 - Overcurrent protection.
Code of Federal Regulations, 2010 CFR
2010-10-01
... emergency switch must be provided in each normally ungrounded main supply conductor from a battery. The switch must be accessible from the battery and located as close as practicable to it. (j) No grounded... type and be listed by Underwriters Laboratories (UL) or another independent laboratory recognized by...
The effect of ambient illuminance on the development of deprivation myopia in chicks.
Ashby, Regan; Ohlendorf, Arne; Schaeffel, Frank
2009-11-01
Recent epidemiologic studies have shown that children who spend a higher proportion of time outdoors are less likely to develop myopia. This study was undertaken to investigate whether light levels may be a relevant factor in the development of myopia. METHODS; Paradigm 1: Chicks were fitted with translucent diffusers for 5 days, with the diffusers removed daily for 15 minutes under one of three lighting conditions: (1) normal laboratory lighting (500 lux), (2) intense laboratory lighting (15,000 lux), or (3) daylight (30,000 lux). A control group, which continuously wore diffusers, was also kept under an illumination of 500 lux. Paradigm 2: Chicks fitted with translucent diffusers were raised for 4 days under one of three lighting conditions: (1) low laboratory lighting (50 lux, n = 9), (2) normal laboratory lighting (500 lux, n = 18), or (3) intense laboratory lights (15,000 lux, n = 9). In groups 1 and 3, the chicks were exposed to either low or high ambient illuminances for a period of 6 hours per day (10 AM-4 PM), but were kept under 500 lux for the remaining time of the light phase. Axial length and refraction were measured at the commencement and cessation of all treatments, with corneal curvature measured additionally in paradigm 2. Paradigm 1: The chicks exposed daily to sunlight for 15 minutes had significantly shorter eyes (8.81 +/- 0.05 mm; P < 0.01) and less myopic refractions (-1.1 +/- 0.45 D; P < 0.01) than did the chicks that had their diffusers removed under normal laboratory light levels (8.98 +/- 0.03 mm, -5.3 +/- 0.5 D). If the diffusers were removed under intense laboratory lights, the chicks also developed shorter eyes (8.88 +/- 0.04 mm; P < 0.01) and less myopic refractions (-3.4 +/- 0.6D; P < 0.01). Paradigm 2: The chicks that wore diffusers continuously under high illuminance had shorter eyes (8.54 +/- 0.02 mm; P < 0.01) and less myopic refractions (+0.04 +/- 0.7D; P < 0.001) compared with those chicks reared under normal light levels (8.64 +/- 0.06 mm, -5.3 +/- 0.9 D). Low illuminance (50 lux) did not further increase deprivation myopia. Exposing chicks to high illuminances, either sunlight or intense laboratory lights, retards the development of experimental myopia. These results, in conjunction with recent epidemiologic findings, suggest that daily exposure to high light levels may have a protective effect against the development of school-age myopia in children.
Pancreatitis with normal lipase and amylase in setting of end-stage renal disease.
Sharma, Anuj; Masood, Umair; Khan, Babar; Chawla, Kunal; Manocha, Divey
2017-09-01
Pancreatitis with normal lipase and amylase level is a rare phenomenon. This is especially true in patient with end-stage renal disease as lipase and amylase are renally excreted. Literature review reveals previous case report of pancreatitis with normal lipase and amylase level, however, none of them occurred in the setting of end-stage renal disease. Our case is the first such reported case of pancreatitis in such setting. Here we report a 30year old male with past medical history of end-stage renal disease who presented in emergency department with acute abdominal pain. Laboratory work up revealed normal lipase and amylase level. However, radiological work up was consistent with pancreatitis. This case report highlight the importance of taking the overall clinical picture rather than laboratory work up to rule in or rule out the diagnosis of pancreatitis. Furthermore, this should also serve an important reminder for clinicians to further investigate where clinical suspicion for pancreatitis is high. Copyright © 2017 Elsevier Inc. All rights reserved.
Normalized velocity profiles of field-measured turbidity currents
Xu, Jingping
2010-01-01
Multiple turbidity currents were recorded in two submarine canyons with maximum speed as high as 280 cm/s. For each individual turbidity current measured at a fixed station, its depth-averaged velocity typically decreased over time while its thickness increased. Some turbidity currents gained in speed as they traveled downcanyon, suggesting a possible self-accelerating process. The measured velocity profiles, first in this high resolution, allowed normalizations with various schemes. Empirical functions, obtained from laboratory experiments whose spatial and time scales are two to three orders of magnitude smaller, were found to represent the field data fairly well. The best similarity collapse of the velocity profiles was achieved when the streamwise velocity and the elevation were normalized respectively by the depth-averaged velocity and the turbidity current thickness. This normalization scheme can be generalized to an empirical function Y = exp(–αXβ) for the jet region above the velocity maximum. Confirming theoretical arguments and laboratory results of other studies, the field turbidity currents are Froude-supercritical.
NASA Astrophysics Data System (ADS)
Lamberty, Andrée; Franks, Katrin; Braun, Adelina; Kestens, Vikram; Roebben, Gert; Linsinger, Thomas P. J.
2011-12-01
The Institute for Reference Materials and Measurements has organised an interlaboratory comparison (ILC) to allow the participating laboratories to demonstrate their proficiency in particle size and zeta potential measurements on monomodal aqueous suspensions of silica nanoparticles in the 10-100 nm size range. The main goal of this ILC was to identify competent collaborators for the production of certified nanoparticle reference materials. 38 laboratories from four different continents participated in the ILC with different methods for particle sizing and determination of zeta potential. Most of the laboratories submitted particle size results obtained with centrifugal liquid sedimentation (CLS), dynamic light scattering (DLS) or electron microscopy (EM), or zeta potential values obtained via electrophoretic light scattering (ELS). The results of the laboratories were evaluated using method-specific z scores, calculated on the basis of consensus values from the ILC. For CLS (13 results) and EM (13 results), all reported values were within the ±2 | z| interval. For DLS, 25 of the 27 results reported were within the ±2 | z| interval, the two other results were within the ±3 | z| interval. The standard deviations of the corresponding laboratory mean values varied between 3.7 and 6.5%, which demonstrates satisfactory interlaboratory comparability of CLS, DLS and EM particle size values. From the received test reports, a large discrepancy was observed in terms of the laboratory's quality assurance systems, which are equally important for the selection of collaborators in reference material certification projects. Only a minority of the participating laboratories is aware of all the items that are mandatory in test reports compliant to ISO/IEC 17025 (ISO General requirements for the competence of testing and calibration laboratories. International Organisation for Standardization, Geneva, 2005b). The absence of measurement uncertainty values in the reports, for example, hindered the calculation of zeta scores.
Bentz, Joe; O’Connor, Michael P.; Bednarczyk, Dallas; Coleman, JoAnn; Lee, Caroline; Palm, Johan; Pak, Y. Anne; Perloff, Elke S.; Reyner, Eric; Balimane, Praveen; Brännström, Marie; Chu, Xiaoyan; Funk, Christoph; Guo, Ailan; Hanna, Imad; Herédi-Szabó, Krisztina; Hillgren, Kate; Li, Libin; Hollnack-Pusch, Evelyn; Jamei, Masoud; Lin, Xuena; Mason, Andrew K.; Neuhoff, Sibylle; Patel, Aarti; Podila, Lalitha; Plise, Emile; Rajaraman, Ganesh; Salphati, Laurent; Sands, Eric; Taub, Mitchell E.; Taur, Jan-Shiang; Weitz, Dietmar; Wortelboer, Heleen M.; Xia, Cindy Q.; Xiao, Guangqing; Yabut, Jocelyn; Yamagata, Tetsuo; Zhang, Lei
2013-01-01
A P-glycoprotein (P-gp) IC50 working group was established with 23 participating pharmaceutical and contract research laboratories and one academic institution to assess interlaboratory variability in P-gp IC50 determinations. Each laboratory followed its in-house protocol to determine in vitro IC50 values for 16 inhibitors using four different test systems: human colon adenocarcinoma cells (Caco-2; eleven laboratories), Madin-Darby canine kidney cells transfected with MDR1 cDNA (MDCKII-MDR1; six laboratories), and Lilly Laboratories Cells—Porcine Kidney Nr. 1 cells transfected with MDR1 cDNA (LLC-PK1-MDR1; four laboratories), and membrane vesicles containing human P-glycoprotein (P-gp; five laboratories). For cell models, various equations to calculate remaining transport activity (e.g., efflux ratio, unidirectional flux, net-secretory-flux) were also evaluated. The difference in IC50 values for each of the inhibitors across all test systems and equations ranged from a minimum of 20- and 24-fold between lowest and highest IC50 values for sertraline and isradipine, to a maximum of 407- and 796-fold for telmisartan and verapamil, respectively. For telmisartan and verapamil, variability was greatly influenced by data from one laboratory in each case. Excluding these two data sets brings the range in IC50 values for telmisartan and verapamil down to 69- and 159-fold. The efflux ratio-based equation generally resulted in severalfold lower IC50 values compared with unidirectional or net-secretory-flux equations. Statistical analysis indicated that variability in IC50 values was mainly due to interlaboratory variability, rather than an implicit systematic difference between test systems. Potential reasons for variability are discussed and the simplest, most robust experimental design for P-gp IC50 determination proposed. The impact of these findings on drug-drug interaction risk assessment is discussed in the companion article (Ellens et al., 2013) and recommendations are provided. PMID:23620485
Reisman, H; Martin, D; Gast, M J
1999-11-01
This study was undertaken to compare the effects of 2 oral contraceptive regimens on menstrual cycle control and laboratory findings. In a multicenter randomized study 100 microg levonorgestrel with 20 microg ethinyl estradiol (Alesse or Loette) was given to 155 healthy women. A triphasic preparation of 500, 750, and 1000 microg norethindrone with 35 microg ethinyl estradiol (Ortho-Novum 7/7/7 or TriNovum) was given to 167 women for 1 to 4 cycles of treatment. Overall, the percentages of normal menstrual cycles and the percentages of cycles with intermenstrual and withdrawal bleeding were similar between the 2 treatment groups. In the levonorgestrel with ethinyl estradiol group, there was a statistically significantly longer latent period and a statistically significantly shorter withdrawal bleeding episode. Adverse events were similar between treatment groups, and none were serious. Most mean changes from baseline laboratory values were comparable between groups, although the mean increase in cholesterol concentration was statistically significantly lower in the levonorgestrel with ethinyl estradiol group. Changes in triglyceride and glucose concentrations were not statistically significantly different between groups. Levonorgestrel (100 microg) with ethinyl estradiol (20 microg) provides menstrual cycle control equivalent to that obtained with triphasic norethindrone with ethinyl estradiol (75% higher estrogen dose) with similar safety and tolerability.
Bennur, Sharath; Tsunada, Joji; Cohen, Yale E; Liu, Robert C
2013-11-01
Acoustic communication between animals requires them to detect, discriminate, and categorize conspecific or heterospecific vocalizations in their natural environment. Laboratory studies of the auditory-processing abilities that facilitate these tasks have typically employed a broad range of acoustic stimuli, ranging from natural sounds like vocalizations to "artificial" sounds like pure tones and noise bursts. However, even when using vocalizations, laboratory studies often test abilities like categorization in relatively artificial contexts. Consequently, it is not clear whether neural and behavioral correlates of these tasks (1) reflect extensive operant training, which drives plastic changes in auditory pathways, or (2) the innate capacity of the animal and its auditory system. Here, we review a number of recent studies, which suggest that adopting more ethological paradigms utilizing natural communication contexts are scientifically important for elucidating how the auditory system normally processes and learns communication sounds. Additionally, since learning the meaning of communication sounds generally involves social interactions that engage neuromodulatory systems differently than laboratory-based conditioning paradigms, we argue that scientists need to pursue more ethological approaches to more fully inform our understanding of how the auditory system is engaged during acoustic communication. This article is part of a Special Issue entitled "Communication Sounds and the Brain: New Directions and Perspectives". Copyright © 2013 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Pande-Chhetri, Roshan
High resolution hyperspectral imagery (airborne or ground-based) is gaining momentum as a useful analytical tool in various fields including agriculture and aquatic systems. These images are often contaminated with stripes and noise resulting in lower signal-to-noise ratio, especially in aquatic regions where signal is naturally low. This research investigates effective methods for filtering high spatial resolution hyperspectral imagery and use of the imagery in water quality parameter estimation and aquatic vegetation classification. The striping pattern of the hyperspectral imagery is non-parametric and difficult to filter. In this research, a de-striping algorithm based on wavelet analysis and adaptive Fourier domain normalization was examined. The result of this algorithm was found superior to other available algorithms and yielded highest Peak Signal to Noise Ratio improvement. The algorithm was implemented on individual image bands and on selected bands of the Maximum Noise Fraction (MNF) transformed images. The results showed that image filtering in the MNF domain was efficient and produced best results. The study investigated methods of analyzing hyperspectral imagery to estimate water quality parameters and to map aquatic vegetation in case-2 waters. Ground-based hyperspectral imagery was analyzed to determine chlorophyll-a (Chl-a) concentrations in aquaculture ponds. Two-band and three-band indices were implemented and the effect of using submerged reflectance targets was evaluated. Laboratory measured values were found to be in strong correlation with two-band and three-band spectral indices computed from the hyperspectral image. Coefficients of determination (R2) values were found to be 0.833 and 0.862 without submerged targets and stronger values of 0.975 and 0.982 were obtained using submerged targets. Airborne hyperspectral images were used to detect and classify aquatic vegetation in a black river estuarine system. Image normalization for water surface reflectance and water depths was conducted and non-parametric classifiers such as ANN, SVM and SAM were tested and compared. Quality assessment indicated better classification and detection when non-parametric classifiers were applied to normalized or depth invariant transform images. Best classification accuracy of 73% was achieved when ANN is applied on normalized image and best detection accuracy of around 92% was obtained when SVM or SAM was applied on depth invariant images.
Krleza, Jasna Lenicek; Dorotic, Adrijana; Grzunov, Ana
2017-02-15
Proper standardization of laboratory testing requires assessment of performance after the tests are performed, known as the post-analytical phase. A nationwide external quality assessment (EQA) scheme implemented in Croatia in 2014 includes a questionnaire on post-analytical practices, and the present study examined laboratory responses in order to identify current post-analytical phase practices and identify areas for improvement. In four EQA exercises between September 2014 and December 2015, 145-174 medical laboratories across Croatia were surveyed using the Module 11 questionnaire on the post-analytical phase of testing. Based on their responses, the laboratories were evaluated on four quality indicators: turnaround time (TAT), critical values, interpretative comments and procedures in the event of abnormal results. Results were presented as absolute numbers and percentages. Just over half of laboratories (56.3%) monitored TAT. Laboratories varied substantially in how they dealt with critical values. Most laboratories (65-97%) issued interpretative comments with test results. One third of medical laboratories (30.6-33.3%) issued abnormal test results without confirming them in additional testing. Our results suggest that the nationwide post-analytical EQA scheme launched in 2014 in Croatia has yet to be implemented to the full. To close the gaps between existing recommendations and laboratory practice, laboratory professionals should focus on ensuring that TAT is monitored and lists of critical values are established within laboratories. Professional bodies/institutions should focus on clarify and harmonized rules to standardized practices and applied for adding interpretative comments to laboratory test results and for dealing with abnormal test results.
Doust, Zarin Keihani; Shariat, Mamak; Zabandan, Neda; Tabrizi, Aidin; Tehrani, Fatemeh
2016-01-01
Background: Childhood masturbation (CM) is considered a variant of normal sexual behavior; however, it is commonly misdiagnosed as epilepsy and movement disorders. As the first study from Iran, we analyzed a large population of infants and children with CM in a case-control study and evaluated the value of mucus in urine analysis as an alternative diagnostic tool for CM. Methods: A total of 623 children referred to the Pediatric Neurology Clinic of Imam Khomeini Hospital for an evaluation of seizure or movement disorders were studied between 2008 and 2011. Totally, 359 children were found to have masturbatory behaviors (Group A) and the rest (264) were assigned to Group B. CM was diagnosed by direct observation. Collected data comprised demographic characteristics, clinical and neurodevelopmental examinations, laboratory findings (particularly urine analysis), and electrocardiography. Results: The age of the children with CM was below 12 years old, and the girl-to-boy ratio was 7:1. Mucus in urine was positive in 357 (99.44%) children in Group A and 22 (8.3%) in Group B (P<0.001). A significant correlation was found between the presence of mucus in urine and masturbatory behaviors (P<0.001). Conclusion: Our findings suggest that the presence of mucus in urine can be used as an alternative laboratory test in children with CM below 12 years old and even in infants (≤24 months old). Further studies are needed to confirm the results. PMID:27365549
Hau, Hans Michael; Bartels, Michael; Tautenhahn, Hans-Michael; Morgul, Mehmet Haluk; Fellmer, Peter; Ho-Thi, Phuc; Benckert, Christoph; Uhlmann, Dirk; Moche, Michael; Thelen, Armin; Schmelzle, Moritz; Jonas, Sven
2012-12-31
We report our contemporary experiences with renal autotransplantation in patients with complicated renal vascular diseases and/or complex ureteral injuries. Since its first performance, renal autotransplantation has been steadily improved and become a safe and effective procedure. Between 1998 and 2006, 6 renal autotransplantations in 6 patients were performed at the University Medical Center of Leipzig. After nephrectomy and renal perfusion ex vivo, the kidney was implanted standardized in the fossa iliaca. The vessels were anastomized to the iliac vessels, the ureter was reimplanted in an extravesical tunneled ureteroneocystostomy technique according to Lich-Gregoir. Demographic, clinical, and laboratory data of the patients were collected and analyzed for pre-, intra-, and postoperative period. Indications for renal autotransplantation were complex renovascular diseases in 2 patients (1 with fibromuscular dysplasia and 1 with Takayasu's arteritis) and in 4 patients with complex ureteral injuries. The median duration of follow-up was 9.7 years (range: 5.6-13.3). The laboratory values of our 6 patients showed improvements of creatinine, urea and blood pressure levels in comparison to the preoperative status at the end of follow-up period. The present study reports excellent results of renal autotransplantation in patients with renovascular disease or complex ureteric injuries. After a median follow-up of 9.7 years all 6 patients present with stable renal function as well as normal blood pressure values. Postoperative complications were observed with a rate comparable to other studies.
Doust, Zarin Keihani; Shariat, Mamak; Zabandan, Neda; Tabrizi, Aidin; Tehrani, Fatemeh
2016-07-01
Childhood masturbation (CM) is considered a variant of normal sexual behavior; however, it is commonly misdiagnosed as epilepsy and movement disorders. As the first study from Iran, we analyzed a large population of infants and children with CM in a case-control study and evaluated the value of mucus in urine analysis as an alternative diagnostic tool for CM. A total of 623 children referred to the Pediatric Neurology Clinic of Imam Khomeini Hospital for an evaluation of seizure or movement disorders were studied between 2008 and 2011. Totally, 359 children were found to have masturbatory behaviors (Group A) and the rest (264) were assigned to Group B. CM was diagnosed by direct observation. Collected data comprised demographic characteristics, clinical and neurodevelopmental examinations, laboratory findings (particularly urine analysis), and electrocardiography. The age of the children with CM was below 12 years old, and the girl-to-boy ratio was 7:1. Mucus in urine was positive in 357 (99.44%) children in Group A and 22 (8.3%) in Group B (P<0.001). A significant correlation was found between the presence of mucus in urine and masturbatory behaviors (P<0.001). Our findings suggest that the presence of mucus in urine can be used as an alternative laboratory test in children with CM below 12 years old and even in infants (≤24 months old). Further studies are needed to confirm the results.
[Clinical, hematological, biochemical and endocrinological aspects of 32 dogs with hypothyroidism].
Boretti, F S; Breyer-Haube, I; Kaspers, B; Reusch, C E
2003-04-01
During the years of 1996-2001, hypothyroidism was diagnosed at the clinic for small animal internal medicine, University of Zurich, in 32 dogs. Most of the dogs were large breeds. The most frequent clinical characteristics observed were exercise intolerance, obesity, dermatological, neurological and gastrointestinal signs. Predominant laboratory abnormalities were a low red blood cell count, increased concentration of cholesterol, triglycerides and fructosamin. 29 dogs had a T4 below the reference range (< 1.5 micrograms/dl), one dog had a T4 at the lower limit thereof (1.6 micrograms/dl). One dog had a T4 within the reference range (3.4 micrograms/dl), another had a very high T4 of 206.8 micrograms/dl; the results of the latter 2 dogs were interpreted as incorrectly increased T4 values due to in vitro interference with T4-autoantibodies. Diagnosis was confirmed in all of the dogs based on TSH-stimulation testing. Endogenous TSH (cTSH) measured parallelly, was elevated in only 60% of the dogs. In about 67% of the dogs, hypothyroidism was associated with thyroglobulin-autoantibodies. Canine hypothyroidism is a rather rare endocrine disorder in Switzerland. The TSH-stimulation test remains the gold standard in confirming the disease; a definitive diagnosis can be challenging for practitioners because bovine TSH, used for the TSH-stimulation test is not licensed for use in dogs. Since assessment of cTSH using current assays shows normal values in a high percentage of hypothyroid dogs, the diagnostic value is only limited. In most of the hypothyroid dogs T4 is decreased, with the presence of autoantibodies to T4, it can be normal or increased.
Takeda, Y; Bige, K; Iwuanyanwu, T; Lewicka, S; Vecsei, P; Abdelhamid, S; Harnik, M
1991-11-01
18,19-Dihydroxycorticosterone (18,19(OH)2-B) and 18-hydroxy-19-norcorticosterone (18-OH-19-nor-B) measurements were carried out on the urine of patients with primary aldosteronism (PA), essential hypertension (EHT), and liver cirrhosis with (LC, SA (+)) and without (LC, SA (-)) aldosteronism. The separation of these steroids was performed by extraction and high-performance liquid chromatography followed by radioimmunoassay (RIA) with specific antibodies prepared in our laboratory. 18,19(OH)2-B excretion was elevated in patients with PA (24 +/- 5.9 [+/- SE] micrograms/24 hr; n = 15) and LC, SA (+) (83 +/- 9.4 micrograms/24 hr; n = 8). Values in LC, SA (-) (3.1 +/- 1.2 micrograms/24 hr; n = 8) and in EHT (3.7 +/- 0.4 micrograms/24 hr; n = 42) were found to be similar to those in normal subjects (5.5 +/- 0.9 micrograms/24 hr; n = 30). The values of urinary 18-OH-19-nor-B in PA and LC, SA (+) were higher than in LC, SA (-) EHT and normal subjects (P less than 0.05). Values in the latter three groups, as compared with each other, did not show significant alterations. Nothing is known about the biologic relevance of 18,19(OH)2-B and very little about that of 18-OH-19-nor-B, but the latter steroid seems to potentiate experimental renal hypertension. One can speculate about possible roles of both steroids as precursors of other steroids, e.g., the biologically potent mineralocorticoid 19-noraldosterone. The data obtained suggest that it is not relevant to measure the urinary levels of either steroid in these clinical syndromes.
Mathematical relationships between metrics of chemical bioaccumulation in fish.
Mackay, Don; Arnot, Jon A; Gobas, Frank A P C; Powell, David E
2013-07-01
Five widely used metrics of bioaccumulation in fish are defined and discussed, namely the octanol-water partition coefficient (KOW ), bioconcentration factor (BCF), bioaccumulation factor (BAF), biomagnification factor (BMF), and trophic magnification factor (TMF). Algebraic relationships between these metrics are developed and discussed using conventional expressions for chemical uptake from water and food and first-order losses by respiration, egestion, biotransformation, and growth dilution. Two BCFs may be defined, namely as an equilibrium partition coefficient KFW or as a nonequilibrium BCFK in which egestion losses are included. Bioaccumulation factors are shown to be the product of the BCFK and a novel equilibrium multiplier M containing 2 ratios, namely, the diet-to-water concentration ratio and the ratio of uptake rate constants for respiration and dietary uptake. Biomagnification factors are shown to be proportional to the lipid-normalized ratio of the predator/prey values of BCFK and the ratio of the equilibrium multipliers. Relationships with TMFs are also discussed. The effects of chemical hydrophobicity, biotransformation, and growth are evaluated by applying the relationships to a range of illustrative chemicals of varying KOW in a linear 4-trophic-level food web with typical values for uptake and loss rate constants. The roles of respiratory and dietary intakes are demonstrated, and even slow rates of biotransformation and growth can significantly affect bioaccumulation. The BCFK s and the values of M can be regarded as the fundamental determinants of bioaccumulation and biomagnification in aquatic food webs. Analyzing data from food webs can be enhanced by plotting logarithmic lipid-normalized concentrations or fugacities as a linear function of trophic level to deduce TMFs. Implications for determining bioaccumulation by laboratory tests for regulatory purposes are discussed. Copyright © 2013 SETAC.
Hallworth, Mike J; Epner, Paul L; Ebert, Christoph; Fantz, Corinne R; Faye, Sherry A; Higgins, Trefor N; Kilpatrick, Eric S; Li, Wenzhe; Rana, S V; Vanstapel, Florent
2015-04-01
Systematic evidence of the contribution made by laboratory medicine to patient outcomes and the overall process of healthcare is difficult to find. An understanding of the value of laboratory medicine, how it can be determined, and the various factors that influence it is vital to ensuring that the service is provided and used optimally. This review summarizes existing evidence supporting the impact of laboratory medicine in healthcare and indicates the gaps in our understanding. It also identifies deficiencies in current utilization, suggests potential solutions, and offers a vision of a future in which laboratory medicine is used optimally to support patient care. To maximize the value of laboratory medicine, work is required in 5 areas: (a) improved utilization of existing and new tests; (b) definition of new roles for laboratory professionals that are focused on optimizing patient outcomes by adding value at all points of the diagnostic brain-to-brain cycle; (c) development of standardized protocols for prospective patient-centered studies of biomarker clinical effectiveness or extraanalytical process effectiveness; (d) benchmarking of existing and new tests in specified situations with commonly accepted measures of effectiveness; (e) agreed definition and validation of effectiveness measures and use of checklists for articles submitted for publication. Progress in these areas is essential if we are to demonstrate and enhance the value of laboratory medicine and prevent valuable information being lost in meaningless data. This requires effective collaboration with clinicians, and a determination to accept patient outcome and patient experience as the primary measure of laboratory effectiveness. © 2014 American Association for Clinical Chemistry.
Kim, Jin Su; Cho, Hanna; Choi, Jae Yong; Lee, Seung Ha; Ryu, Young Hoon; Lyoo, Chul Hyoung; Lee, Myung Sik
2015-01-01
Spatial normalization is a prerequisite step for analyzing positron emission tomography (PET) images both by using volume-of-interest (VOI) template and voxel-based analysis. Magnetic resonance (MR) or ligand-specific PET templates are currently used for spatial normalization of PET images. We used computed tomography (CT) images acquired with PET/CT scanner for the spatial normalization for [18F]-N-3-fluoropropyl-2-betacarboxymethoxy-3-beta-(4-iodophenyl) nortropane (FP-CIT) PET images and compared target-to-cerebellar standardized uptake value ratio (SUVR) values with those obtained from MR- or PET-guided spatial normalization method in healthy controls and patients with Parkinson's disease (PD). We included 71 healthy controls and 56 patients with PD who underwent [18F]-FP-CIT PET scans with a PET/CT scanner and T1-weighted MR scans. Spatial normalization of MR images was done with a conventional spatial normalization tool (cvMR) and with DARTEL toolbox (dtMR) in statistical parametric mapping software. The CT images were modified in two ways, skull-stripping (ssCT) and intensity transformation (itCT). We normalized PET images with cvMR-, dtMR-, ssCT-, itCT-, and PET-guided methods by using specific templates for each modality and measured striatal SUVR with a VOI template. The SUVR values measured with FreeSurfer-generated VOIs (FSVOI) overlaid on original PET images were also used as a gold standard for comparison. The SUVR values derived from all four structure-guided spatial normalization methods were highly correlated with those measured with FSVOI (P < 0.0001). Putaminal SUVR values were highly effective for discriminating PD patients from controls. However, the PET-guided method excessively overestimated striatal SUVR values in the PD patients by more than 30% in caudate and putamen, and thereby spoiled the linearity between the striatal SUVR values in all subjects and showed lower disease discrimination ability. Two CT-guided methods showed comparable capability with the MR-guided methods in separating PD patients from controls and showed better correlation between putaminal SUVR values and the parkinsonian motor severity than the PET-guided method. CT-guided spatial normalization methods provided reliable striatal SUVR values comparable to those obtained with MR-guided methods. CT-guided methods can be useful for analyzing dopamine transporter PET images when MR images are unavailable.
Kim, Jin Su; Cho, Hanna; Choi, Jae Yong; Lee, Seung Ha; Ryu, Young Hoon; Lyoo, Chul Hyoung; Lee, Myung Sik
2015-01-01
Background Spatial normalization is a prerequisite step for analyzing positron emission tomography (PET) images both by using volume-of-interest (VOI) template and voxel-based analysis. Magnetic resonance (MR) or ligand-specific PET templates are currently used for spatial normalization of PET images. We used computed tomography (CT) images acquired with PET/CT scanner for the spatial normalization for [18F]-N-3-fluoropropyl-2-betacarboxymethoxy-3-beta-(4-iodophenyl) nortropane (FP-CIT) PET images and compared target-to-cerebellar standardized uptake value ratio (SUVR) values with those obtained from MR- or PET-guided spatial normalization method in healthy controls and patients with Parkinson’s disease (PD). Methods We included 71 healthy controls and 56 patients with PD who underwent [18F]-FP-CIT PET scans with a PET/CT scanner and T1-weighted MR scans. Spatial normalization of MR images was done with a conventional spatial normalization tool (cvMR) and with DARTEL toolbox (dtMR) in statistical parametric mapping software. The CT images were modified in two ways, skull-stripping (ssCT) and intensity transformation (itCT). We normalized PET images with cvMR-, dtMR-, ssCT-, itCT-, and PET-guided methods by using specific templates for each modality and measured striatal SUVR with a VOI template. The SUVR values measured with FreeSurfer-generated VOIs (FSVOI) overlaid on original PET images were also used as a gold standard for comparison. Results The SUVR values derived from all four structure-guided spatial normalization methods were highly correlated with those measured with FSVOI (P < 0.0001). Putaminal SUVR values were highly effective for discriminating PD patients from controls. However, the PET-guided method excessively overestimated striatal SUVR values in the PD patients by more than 30% in caudate and putamen, and thereby spoiled the linearity between the striatal SUVR values in all subjects and showed lower disease discrimination ability. Two CT-guided methods showed comparable capability with the MR-guided methods in separating PD patients from controls and showed better correlation between putaminal SUVR values and the parkinsonian motor severity than the PET-guided method. Conclusion CT-guided spatial normalization methods provided reliable striatal SUVR values comparable to those obtained with MR-guided methods. CT-guided methods can be useful for analyzing dopamine transporter PET images when MR images are unavailable. PMID:26147749
NASA Astrophysics Data System (ADS)
Sun, W.; Maseyk, K. S.; Lett, C.; Seibt, U.
2017-12-01
Using carbonyl sulfide (COS) as a tracer to derive gross primary productivity (GPP) estimates requires knowledge of the relationship between leaf COS and CO2 uptake, which is typically embodied in a parameter called leaf relative uptake (LRU) ratio, defined as the concentration normalized COS:CO2 flux ratio. Previous laboratory and field studies have found light as the key environmental driver of LRU due to differential light responses of COS and CO2 uptake imposed by stomatal regulation. But the influences on LRU from other environmental drivers, particularly vapor pressure deficit (VPD) that affects stomatal conductance, remain elusive. Here we show that VPD is an important determinant of the COS-CO2 uptake relationship in a water-stressed ecosystem. We measured leaf COS and CO2 fluxes from a coast live oak with automated leaf chambers in spring 2013 in a southern Californian woodland. In this semiarid ecosystem, both leaf COS and CO2 uptake responded to VPD and showed a midday depression caused by reduced stomatal conductance. Above a moderate light level ( 500 µmol m-2 s-1), COS uptake decreased with light, whereas CO2 uptake saturated. As a result of the VPD-limited COS uptake, LRU value became smaller than 1.0 at high light (> 1000 µmol m-2 s-1), strongly deviating from previous laboratory values that converge to 1.6. Hence, failure to consider VPD influence may result in overestimated LRU value and underestimated CO2 uptake in this ecosystem. Using a coupled photosynthesis-stomatal conductance model, we show that the VPD control on LRU is in accordance with the response of stomatal conductance to VPD. Our results highlight that incorporating the VPD effect into the prediction of LRU value is crucial to the implementation of COS-based photosynthesis estimates in semiarid ecosystems.
An Integrated Protein Chemistry Laboratory: Chlorophyll and Chlorophyllase
ERIC Educational Resources Information Center
Arkus, Kiani A. J.; Jez, Joseph M.
2008-01-01
Chlorophyll, the most abundant pigment in nature, is degraded during normal plant growth, when leaves change color, and at specific developmental stages. Chlorophyllase catalyzes the first chemical reaction in this process, that is, the hydrolysis of chlorophyll into chlorophyllide. Here, we describe a series of laboratory sessions designed to…
ERIC Educational Resources Information Center
Russell, Cianán B.; Mason, Jeremy D.; Bean, Theodore G.; Murphree, S. Shaun
2014-01-01
An instructional laboratory curriculum for a first-semester introductory organic chemistry course has been developed using microwave-assisted organic synthesis (MAOS). Taking advantage of short reaction times, materials were developed to facilitate collaborative experimental design, analysis, and debriefing of results during the normal laboratory…
Proceedings of the Geophysical Laboratory/Lawrence Radiation Laboratory Cratering Symposium
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nordyke, Milo D.
1961-10-01
The geological papers in this morning's session will deal descriptively with surficial features and end products of impact craters caused by meteorite falls. Such items as breccia, structural deformation, normal and inverse stratigraphy, glass (fused rock), and coesite will frequently be mentioned. Meteor and explosion crater data are presented.
Ion-molecule calculation of the abundance ratio of CCD to CCH in dense interstellar clouds
NASA Technical Reports Server (NTRS)
Herbst, Eric; Adams, Nigel G.; Smith, David; Defrees, D. J.
1987-01-01
Laboratory measurements and calculations have been performed to determine the abundance ratio of the deuterated ethynyl radical (CCD) to the normal radical (CCH) which can be achieved in dense interstellar clouds via isotopic fractionation in the C2H2(+) (HD)=C2HD(+)(H2) system of reactions. According to this limited treatment, the CCD/CCH abundance ratio which can be attained is in the range 0.02-0.03 for the Orion molecular cloud and 0.0l-0.02 for TMC-1. These ranges of numbers are in reasonable agreement with the observed values in Orion and TMC-1. However, the analysis of the CCD/CCH abundance ratio is complicated via the presence of competing fractionation mechanisms, especially in the low-temperature source TMC-1.
Feline focus: Diagnostic testing for feline thyroid disease: hypothyroidism.
Peterson, Mark E
2013-08-01
Although naturally occurring hypothyroidism is very rare in cats, iatrogenic hypothyroidism is a recognized complication of treatment for hyperthyroidism. However, confirming the diagnosis of hypothyroidism in cats is not generally straightforward. The potential for false-negative and false-positive results exists with all thyroid function tests, especially in older cats that may have concurrent nonthyroidal illness. Therefore, all thyroid function test results must be interpreted in light of the cat's history, clinical signs, and other laboratory findings. If a low to low-normal serum thyroxine (T4) value is found in a cat that has been treated for hyperthyroidism, repeating the total T4 analysis, determining free T4 and thyroid stimulating hormone (TSH) concentrations, or performing a TSH stimulation test or thyroid scintigraphy may be needed to confirm the diagnosis.
Ling, C. R.; Foster, M. A.; Mallard, J. R.
1979-01-01
In separate experiments, normal foreign tissue and malignant tumour were implanted s.c. into the rat thigh. NMR T1 values of the adjacent normal muscle, resulting from local inflammatory reactions or from malignant invasion, were measured. Elevations in T1 of the underlying muscle occurred within 24 h in both experiments, and it is believed these were caused by rapid inflammatory and immunological reactions to the implants. However the T1 values of muscle samples adjacent to the non-malignant implants decreased during the 11 days after implantation, dropping to values within the normal range. In the second experiment there was progressive malignant invasion into the normal adjacent tissue and the elevated T1 values were maintained throughout the 12-day period. The effects of the implantation on tissue water content are discussed in relation to NMR T1 relaxation times, and the relevance to whole-body NMR imaging of elevated T1 values due to nonmalignant pathological states is considered. PMID:526431
Kim, Choong Hyun; Kim, Jae Min; Cheong, Jin Hwan; Ryu, Je il
2017-01-01
Background and purpose Hydrocephalus is a frequent complication following subarachnoid hemorrhage. Few studies investigated the association between laboratory parameters and shunt-dependent hydrocephalus. This study aimed to investigate the variations of laboratory parameters after subarachnoid hemorrhage. We also attempted to identify predictive laboratory parameters for shunt-dependent hydrocephalus. Methods Multiple imputation was performed to fill the missing laboratory data using Bayesian methods in SPSS. We used univariate and multivariate Cox regression analyses to calculate hazard ratios for shunt-dependent hydrocephalus based on clinical and laboratory factors. The area under the receiver operating characteristic curve was used to determine the laboratory risk values predicting shunt-dependent hydrocephalus. Results We included 181 participants with a mean age of 54.4 years. Higher sodium (hazard ratio, 1.53; 95% confidence interval, 1.13–2.07; p = 0.005), lower potassium, and higher glucose levels were associated with higher shunt-dependent hydrocephalus. The receiver operating characteristic curve analysis showed that the areas under the curve of sodium, potassium, and glucose were 0.649 (cutoff value, 142.75 mEq/L), 0.609 (cutoff value, 3.04 mmol/L), and 0.664 (cutoff value, 140.51 mg/dL), respectively. Conclusions Despite the exploratory nature of this study, we found that higher sodium, lower potassium, and higher glucose levels were predictive values for shunt-dependent hydrocephalus from postoperative day (POD) 1 to POD 12–16 after subarachnoid hemorrhage. Strict correction of electrolyte imbalance seems necessary to reduce shunt-dependent hydrocephalus. Further large studies are warranted to confirm our findings. PMID:29232410
Burney, Peter; Minelli, Cosetta
2018-01-01
The impact of disease on population health is most commonly estimated by the population attributable fraction (PAF), or less commonly by the excess risk, an alternative measure that estimates the absolute risk of disease in the population that can be ascribed to the exposure. Using chronic airflow obstruction as an example, we examined the impact on these estimates of defining disease based on different "normal" values. We estimated PAF and the excess risk in scenarios in which the true rate of disease was 10% in the exposed and 5% in the unexposed, and where either 50% or 20% of the population was exposed. Disease definition was based on a "lower limit of normal", using the 5th, 1st and 0.2nd centile of values in a "normal" population as thresholds to define normality. Where normality is defined by centiles of values in a "normal" population, PAF is strongly influenced by which centile is selected to define normality. This is not true for the population excess risk. Care should be taken when interpreting estimates of PAF when disease is defined from a centile of a normal population. Copyright © 2017 Elsevier Inc. All rights reserved.
Measurements of normal joint angles by goniometry in calves.
Sengöz Şirin, O; Timuçin Celik, M; Ozmen, A; Avki, S
2014-01-01
The aim of this study was to establish normal reference values of the forelimb and hindlimb joint angles in normal Holstein calves. Thirty clinically normal Holstein calves that were free of any detectable musculoskeletal abnormalities were included in the study. A standard transparent plastic goniometer was used to measure maximum flexion, maximum extension, and range-of-motion of the shoulder, elbow, carpal, hip, stifle, and tarsal joints. The goniometric measurements were done on awake calves that were positioned in lateral recumbency. The goniometric values were measured and recorded by two independent investigators. As a result of the study it was concluded that goniometric values obtained from awake calves in lateral recumbency were found to be highly consistent and accurate between investigators (p <0.05). The data of this study acquired objective and useful information on the normal forelimb and hindlimb joint angles in normal Holstein calves. Further studies can be done to predict detailed goniometric values from different diseases and compare them.
Trilateral interlaboratory with SSL (WLEDi) luminaire
NASA Astrophysics Data System (ADS)
Burini Junior, E. C.; Santos, E. R.; Assaf, L. O.
2018-03-01
The IEE/USP laboratory and two others, all belonging to RBLE (Brazilian Network of Test Laboratories) participated in a trilateral comparison performed from measurement independently of participants interaction. The results from electric and photometric measurements carried out on samples of Solid State Lighting - SSL, Inorganic White Light Emitting Diode (WLEDi) luminaires by three accredited laboratories were considered in order to point out mutual deviations and to verify the confidence in a bilateral comparison. The first analysis revealed a maximum deviation of 4.2 % between the luminous intensity attributed by one laboratory and the arithmetic mean value from three laboratories. The largest standard uncertainty value of 1.9 % was estimated for Total Harmonic Distortion of electric current THDi and the lowest value, 0.4 %, to the luminous flux. The extreme deviation for one parameter results was 7.2 % at maximum luminous intensity and the lowest was 1.7 % for luminous flux.
Faster, better, cheaper: lean labs are the key to future survival.
Bryant, Patsy M; Gulling, Richard D
2006-03-28
Process improvement techniques have been used in manufacturing for many years to rein in costs and improve quality. Health care is now grappling with similar challenges. The Department of Laboratory Services at Good Samaritan Hospital, a 560-bed facility in Dayton, OH, used the Lean process improvement method in a 12-week project to streamline its core laboratory processes. By analyzing the flow of samples through the system and identifying value-added and non-value-added steps, both in the laboratory and during the collection process, Good Samaritan's project team redesigned systems and reconfigured the core laboratory layout to trim collection-to-results time from 65 minutes to 40 minutes. As a result, virtually all morning results are available to physicians by 7 a.m., critical values are called to nursing units within 30 minutes, and core laboratory services are optimally staffed for maximum cost-effectiveness.
Relocation of blood gas laboratory to the emergency department helps decrease lactic acid values.
Brazg, Jared; Huang, Phyllis; Weiner, Corey; Singh, Guneet; Likourezos, Antonios; Salem, Linda; Dickman, Eitan; Marshall, John
2018-03-20
Emergency physicians often rely on Lactic Acid (LA) values to make important clinical decisions. Accuracy of LA values improve when blood gas analysis is performed in the emergency department (ED) as opposed to a satellite laboratory (SL). To investigate an association between blood gas laboratory location and accuracy of ED lactic acid samples. The study team evaluated lactic acid values from venous and arterial blood gas samples drawn between June 1, 2015 and September 30, 2016. The study was exempt from institutional review board approval. Samples were separated into two groups: those which were drawn prior to and after relocation of the blood gas laboratory to the ED. The data, including patient demographic characteristics, acute illness severity indices, and blood gas results were compared within and between each group using t-test for continuous variables and chi-square test for categorical variables. The primary outcome was the mean lactate value measured in the SL group in 2015 compared to the ED group in 2016. Potassium and creatinine values were measured between the two groups as secondary outcomes. Of the 21,595 consecutive samples drawn, 10,363 samples were from the SL group and 11,232 from the ED group. The SL group included 5458 (52.7%) women; mean (SD) age was 61.8 (21.0). The ED group contained 5860 (52.2%) women; mean (SD) age was 61.7 (20.5). Mean Emergency Severity Index (ESI) were the same in each group at 2.31 and rates of Systemic Inflammatory Response Syndrome (SIRS) were also equivalent in each group at 22.2%. Significant differences were found between LA values in the SL group (mean 2.21mmol/L) and in the ED group (mean 1.99mmol/L) with a p value of <0.0001. There was a small statistical significance between the difference in potassium values in the SL group (mean 3.98meq/L) compared to the ED Group (mean 3.96meq/L) with a p value of 0.022. No significant difference was found between the creatinine values. These results suggest that mean lactate values decreased when measured in an ED blood gas laboratory and may provide more accurate LA results than blood gas samples analyzed at an SL blood gas laboratory within the same institution. Hospitals may consider moving blood gas laboratories to the ED to improve accuracy of one of the most important early blood markers used in the definition of sepsis and in the identification of the critically ill. Copyright © 2018 Elsevier Inc. All rights reserved.
Relocation of blood gas laboratory to the emergency department helps decrease lactic acid values.
Brazg, Jared; Huang, Phyllis; Weiner, Corey; Singh, Guneet; Likourezos, Antonios; Salem, Linda; Dickman, Eitan; Marshall, John
2018-03-12
Emergency Physicians often rely on Lactic Acid (LA) values to make important clinical decisions. Accuracy of LA values improve when blood gas analysis is performed in the emergency department (ED) as opposed to a satellite laboratory (SL). To investigate an association between blood gas laboratory location and accuracy of ED lactic acid samples. The study team evaluated lactic acid values from venous and arterial blood gas samples drawn between June 1, 2015 and September 30, 2016. The study was exempt from institutional review board approval. Samples were separated into two groups: those which were drawn prior to and after relocation of the blood gas laboratory to the ED. The data, including patient demographic characteristics, acute illness severity indices, and blood gas results were compared within and between each group using t-test for continuous variables and chi-square test for categorical variables. The primary outcome was the mean lactate value measured in the SL group in 2015 compared to the ED group in 2016. Potassium and creatinine values were measured between the two groups as secondary outcomes. Of the 21,595 consecutive samples drawn, 10,363 samples were from the SL group and 11,232 from the ED group. The SL group included 5458 (52.7%) women; mean (SD) age was 61.8 (21.0). The ED group contained 5860 (52.2%) women; mean (SD) age was 61.7 (20.5). Mean Emergency Severity Index (ESI) were the same in each group at 2.31 and rates of Systemic Inflammatory Response Syndrome (SIRS) were also equivalent in each group at 22.2%. Significant differences were found between LA values in the SL group (mean 2.21mmol/L) and in the ED group (mean 1.99mmol/L) with a p value of <0.0001. There was a small statistical significance between the difference in potassium values in the SL group (mean 3.98meq/L) compared to the ED Group (mean 3.96meq/L) with a p value of 0.022. No significant difference was found between the creatinine values. These results suggest that mean lactate values decreased when measured in an ED blood gas laboratory and may provide more accurate LA results than blood gas samples analyzed at an SL blood gas laboratory within the same institution. Hospitals may consider moving blood gas laboratories to the ED to improve accuracy of one of the most important early blood markers used in the definition of sepsis and in the identification of the critically ill. Copyright © 2018 Elsevier Inc. All rights reserved.
Kumar, Manoj; Sharma, Praveen; Garg, Hitendra; Kumar, Ramesh; Bhatia, Vikram; Sarin, Shiv K
2011-08-01
Studies on normal values of liver stiffness (LS) in subjects at "low risk" for liver disease are scant. The aim of the present study was to assess liver stiffness values in the subjects without overt liver disease with normal alanine aminotransferases (ALT) and to determine potential factors, which may influence these values with special reference to newly suggested updated upper limits of normal for ALT. Liver stiffness measurements were performed in 445 subjects without overt liver disease (mean age, 41.1±13.6; male, 73.5%) and normal liver enzymes. Mean LS value was 5.10±1.19kPa. LS values were higher in men than in women (5.18±1.67 vs 4.86±1.24kPa, respectively, P=0.008); in subjects with higher body mass index (BMI) category (Normal, overweight and obese subjects; 4.10±0.75, 5.08±0.66, and 6.05±1.28kPa, respectively; P<0.001); in subjects with metabolic syndrome than in those without (5.63±1.37 vs 5.01±1.14kPa, P=0.001); and in subjects with ALT levels more than updated limits of normal compared to subjects with ALT levels less than updated limits of normal (5.68±1.21 vs 4.77±1.05kPa, P<0.001). On multiple linear regression, BMI and ALT was found to be significant predictor of LS. Liver stiffness values in subjects without overt liver disease with normal ALT are influenced by BMI and ALT levels. Subjects with ALT levels less than updated limits of normal have lower LS values as compared to those with higher levels. © 2011 Journal of Gastroenterology and Hepatology Foundation and Blackwell Publishing Asia Pty Ltd.
The estimation of parameter compaction values for pavement subgrade stabilized with lime
NASA Astrophysics Data System (ADS)
Lubis, A. S.; Muis, Z. A.; Simbolon, C. A.
2018-02-01
The type of soil material, field control, maintenance and availability of funds are several factors that must be considered in compaction of the pavement subgrade. In determining the compaction parameters in laboratory desperately requires considerable materials, time and funds, and reliable laboratory operators. If the result of soil classification values can be used to estimate the compaction parameters of a subgrade material, so it would save time, energy, materials and cost on the execution of this work. This is also a clarification (cross check) of the work that has been done by technicians in the laboratory. The study aims to estimate the compaction parameter values ie. maximum dry unit weight (γdmax) and optimum water content (Wopt) of the soil subgrade that stabilized with lime. The tests that conducted in the laboratory of soil mechanics were to determine the index properties (Fines and Liquid Limit/LL) and Standard Compaction Test. Soil samples that have Plasticity Index (PI) > 10% were made with additional 3% lime for 30 samples. By using the Goswami equation, the compaction parameter values can be estimated by equation γd max # = -0,1686 Log G + 1,8434 and Wopt # = 2,9178 log G + 17,086. From the validation calculation, there was a significant positive correlation between the compaction parameter values laboratory and the compaction parameter values estimated, with a 95% confidence interval as a strong relationship.
Palm-Based Standard Reference Materials for Iodine Value and Slip Melting Point
Tarmizi, Azmil Haizam Ahmad; Lin, Siew Wai; Kuntom, Ainie
2008-01-01
This work described study protocols on the production of Palm-Based Standard Reference Materials for iodine value and slip melting point. Thirty-three laboratories collaborated in the inter-laboratory proficiency tests for characterization of iodine value, while thirty-two laboratories for characterization of slip melting point. The iodine value and slip melting point of palm oil, palm olein and palm stearin were determined in accordance to MPOB Test Methods p3.2:2004 and p4.2:2004, respectively. The consensus values and their uncertainties were based on the acceptability of statistical agreement of results obtained from collaborating laboratories. The consensus values and uncertainties for iodine values were 52.63 ± 0.14 Wijs in palm oil, 56.77 ± 0.12 Wijs in palm olein and 33.76 ± 0.18 Wijs in palm stearin. For the slip melting points, the consensus values and uncertainties were 35.6 ± 0.3 °C in palm oil, 22.7 ± 0.4 °C in palm olein and 53.4 ± 0.2 °C in palm stearin. Repeatability and reproducibility relative standard deviations were found to be good and acceptable, with values much lower than that of 10%. Stability of Palm-Based Standard Reference Materials remained stable at temperatures of −20 °C, 0 °C, 6 °C and 24 °C upon storage for one year. PMID:19609396
Touger, Michael; Birnbaum, Adrienne; Wang, Jessica; Chou, Katherine; Pearson, Darion; Bijur, Polly
2010-10-01
We assess agreement between carboxyhemoglobin levels measured by the Rad-57 signal extraction pulse CO-oximeter (RAD), a Food and Drug Administration-approved device for noninvasive bedside measurement, and standard laboratory arterial or venous measurement in a sample of emergency department (ED) patients with suspected carbon monoxide poisoning. The study was a cross-sectional cohort design using a convenience sample of adult and pediatric ED patients in a Level I trauma, burn, and hyperbaric oxygen referral center. Measurement of RAD carboxyhemoglobin was performed simultaneously with blood sampling for laboratory determination of carboxyhemoglobin level. The difference between the measures for each patient was calculated as laboratory carboxyhemoglobin minus carboxyhemoglobin from the carbon monoxide oximeter. The limits of agreement from a Bland-Altman analysis are calculated as the mean of the differences between methods ±1.96 SDs above and below the mean. Median laboratory percentage carboxyhemoglobin level was 2.3% (interquartile range 1 to 8.5; range 0% to 38%). The mean difference between laboratory carboxyhemoglobin values and RAD values was 1.4% carboxyhemoglobin (95% confidence interval [CI] 0.2% to 2.6%). The limits of agreement of differences of measurement made with the 2 devices were -11.6% and 14.4% carboxyhemoglobin. This range exceeded the value of ±5% carboxyhemoglobin defined a priori as clinically acceptable. RAD correctly identified 11 of 23 patients with laboratory values greater than 15% carboxyhemoglobin (sensitivity 48%; 95% CI 27% to 69%). There was one case of a laboratory carboxyhemoglobin level less than 15%, in which the RAD device gave a result greater than 15% (specificity of RAD 96/97=99%; 95% CI 94% to 100%). In the range of carboxyhemoglobin values measured in this sample, the level of agreement observed suggests RAD measurement may not be used interchangeably with standard laboratory measurement. Copyright © 2010 American College of Emergency Physicians. Published by Mosby, Inc. All rights reserved.
Pulse oximetry in the evaluation of peripheral vascular disease.
Jawahar, D; Rachamalla, H R; Rafalowski, A; Ilkhani, R; Bharathan, T; Anandarao, N
1997-08-01
The role of pulse oximetry in the evaluation of peripheral vascular disease (PVD) was investigated. In addition, the value of elevating the limb to improve the sensitivity of detection of PVD by the pulse oximeter was also determined. Pulse oximetry reading in the toes were obtained in 40 young, healthy volunteers and in 40 randomly selected patients referred to the vascular investigation laboratory over a period of two months. All 40 healthy volunteers had normal pulse oximetry readings. Normal pulse oximetry reading in the toes was defined as > 95% O2 Sat and +/-2 of finger pulse oximetry reading. In all 40 patients, pulse oximetry readings were either normal or not detected at all. Since there was no gradation in decrease in the pulse oximetry reading with severity of disease or with elevation of the patient's lower extremity, an absent or no reading was considered as an abnormal result from the test. The frequency of abnormal pulse oximetry readings increased significantly in groups with abnormal ankle-brachial pressure index (ABPI) and also varied significantly with elevation of the patients' lower limbs. In patients with no PVD detected by Doppler (ABPI > 0.9), pulse oximetry readings were normal in all. However, in patients with moderate PVD (ABPI, 0.5-0.9), 84% of the patients' lower limbs had normal pulse oximetry readings and 16% had an abnormal reading at baseline level (flat). An additional 12% of the lower limbs in this group had an abnormal reading on elevation of the limb to 12 inches. In patients with severe PVD (ABPI < 0.5), 54% of the patients' lower limbs had an abnormal reading at baseline and an additional 23% had an abnormal reading at elevation of the limb to 12 inches. In conclusion, pulse oximetry was not a sensitive test for detecting early PVD.
El-Merhi, Fadi; Mohamad, May; Haydar, Ali; Naffaa, Lena; Nasr, Rami; Deeb, Ibrahim Al-Sheikh; Hamieh, Nadine; Tayara, Ziad; Saade, Charbel
2018-04-01
To evaluate the performance of non-contrast computed tomography (CT) by reporting the difference in attenuation between normal and inflamed renal parenchyma in patients clinically diagnosed with acute pyelonephritis (APN). This is a retrospective study concerned with non-contrast CT evaluation of 74 patients, admitted with a clinical diagnosis of APN and failed to respond to 48h antibiotics treatment. Mean attenuation values in Hounsfield units (HU) were measured in the upper, middle and lower segments of the inflamed and the normal kidney of the same patient. Independent t-test was performed for statistical analysis. Image evaluation included receiver operating characteristic (ROC), visual grading characteristic (VGC) and kappa analyses. The mean attenuation in the upper, middle and lower segments of the inflamed renal cortex was 32%, 25%, and 29% lower than the mean attenuation of the corresponding cortical segments of the contralateral normal kidney, respectively (p<0.01). The mean attenuation in the upper, middle, and lower segments of the inflamed renal medulla was 48%, 21%, and 30%, lower than the mean attenuation of the corresponding medullary segments of the contralateral normal kidney (p<0.02). The mean attenuation between the inflamed and non-inflamed renal cortex and medulla was 29% and 30% lower respectively (p<0.001). The AUCROC (p<0.001) analysis demonstrated significantly higher scores for pathology detection, irrespective of image quality, compared to clinical and laboratory results with an increased inter-reader agreement from poor to substantial. Non-contrast CT showed a significant decrease in the parenchymal density of the kidney affected with APN in comparison to the contralateral normal kidney of the same patient. This can be incorporated in the diagnostic criteria of APN in NCCT in the emergency setting. Copyright © 2017 Elsevier Inc. All rights reserved.
[GHBP, IGF-1 and IGFBP-3 serum levels in familial short-statured and normal-statured children].
del Valle Núñez, Cristóbal Jorge; López-Siguero, Juan Pedro; López-Canti, Luis Fernando; Lechuga Campoy, José Luis; Espigares Martín, Rosa; Martínez-Aedo Ollero, María José
2004-10-09
Growth hormone binding protein (GHBP), insuline-like growth factor 1 (IGF-1) and insuline-like growth factor binding protein 3 (IGFBP-3) serum concentrations were studied in familial short-statured patients (FSS) and age-matched normal-statured subjects. The aim of the study was to ascertain whether differences in growth factors concentrations between groups could be shown and whether they may contribute to explaining the different patterns of growth in both groups. Serum samples of 38 FSS patients (20 boys) and 31 normal-statured subjects (15 boys) in Tanner I stage (prepubertal), were analysed in a central laboratory. All auxological parameters (height, growth velocity, target height, body mass index (BMI) and biochemical parameters (IGF-1 and IGFBP-3) were standardised for age and sex-matched subjects. GHBP values were expressed as percentage of specific binding. The studied populations were similar and no statistically-significant differences in chronological age, bone age and BMI were found. Height, growth velocity and target height were significantly lower in FSS patients compared with normal subjects (p < 0.0001). IGF-1, IGFBP-3 and GHBP concentrations were significantly lower in the FSS group (p < 0.01). Correlations were found between IGF-1 and IGFBP-3 (r = 0.56; p = 0.0004) and between IGF-1 and GHBP (r = 0.34; p = 0.03) in the FSS group. However, in the normal-statured group only BMI and GHBP were correlated (r = 0.5; p = 0.02). These results strongly support the importance of the GH/IGF-1 functional axis in the pattern of growth and probably contribute to understanding of the pathophysiologic basis of the auxological differences found between groups.
Schroer, A F W; Belgers, J D M; Brock, T C M; Matser, A M; Maund, S J; Van den Brink, P J
2004-04-01
The toxicity of the pyrethroid insecticide lambda-cyhalothrin to freshwater invertebrates has been investigated using data from short-term laboratory toxicity tests and in situ bioassays and population-level effects in field microcosms. In laboratory tests, patterns of toxicity were consistent with previous data on pyrethroids. The midge Chaoborus obscuripes was most sensitive (48- and 96-h EC50 = 2.8 ng/L). Other insect larvae (Hemiptera, Ephemeroptera) and macrocrustacea (Amphipoda, Isopoda) were also relatively sensitive, with 48- and 96-h EC50 values between 10 and 100 ng/L. Generally, microcrustacea (Cladocera, Copepoda) and larvae of certain insect groups (Odonata and Chironomidae) were less sensitive, with 48-h EC50 values higher than 100 ng/L. Mollusca and Plathelminthes were insensitive and were unaffected at concentrations at and above the water solubility (5 microg/L). Generally, the EC50 values based on initial population responses in field enclosures were similar to values derived from laboratory tests with the same taxa. Also, the corresponding fifth and tenth percentile hazard concentrations (HC5 and HC10) were similar (laboratory HC5 = 2.7 ng/L and field HC5 = 4.1 ng/L; laboratory and field HC10 = 5.1 ng/L), at least when based on the same sensitive taxonomic groups (insects and crustaceans) and when a similar concentration range was taken into account. In the three field enclosure experiments and at a treatment level of 10 ng/L, consistent effects were observed for only one population (Chaoborus obscuripes), with recovery taking place within 3 to 6 weeks. The laboratory HC5 (2.7 ng/L) and HC10 (5.1 ng/L) based on acute EC50 values of all aquatic arthropod taxa were both lower than this 10 ng/L, a concentration that might represent the "regulatory acceptable concentration." The HC5 and HC10 values in this study in The Netherlands (based on static laboratory tests with freshwater arthropods) were very similar to those derived from a previous study in the United Kingdom (1.4 and 3.3 ng/L). This suggests that for pesticides like lambda-cyhalothrin, HC5 values based on static laboratory tests may provide a conservative estimate of the potential for community-level effects under field conditions. While these HC5 values are conservative for initial effects, they do not provide information on recovery potential, which may be important for regulatory decision-making.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Webb-Robertson, Bobbie-Jo M.; Matzke, Melissa M.; Jacobs, Jon M.
2011-12-01
Quantification of LC-MS peak intensities assigned during peptide identification in a typical comparative proteomics experiment will deviate from run-to-run of the instrument due to both technical and biological variation. Thus, normalization of peak intensities across a LC-MS proteomics dataset is a fundamental step in pre-processing. However, the downstream analysis of LC-MS proteomics data can be dramatically affected by the normalization method selected . Current normalization procedures for LC-MS proteomics data are presented in the context of normalization values derived from subsets of the full collection of identified peptides. The distribution of these normalization values is unknown a priori. If theymore » are not independent from the biological factors associated with the experiment the normalization process can introduce bias into the data, which will affect downstream statistical biomarker discovery. We present a novel approach to evaluate normalization strategies, where a normalization strategy includes the peptide selection component associated with the derivation of normalization values. Our approach evaluates the effect of normalization on the between-group variance structure in order to identify candidate normalization strategies that improve the structure of the data without introducing bias into the normalized peak intensities.« less
Novel Monitoring Techniques for Characterizing Frictional Interfaces in the Laboratory
Selvadurai, Paul A.; Glaser, Steven D.
2015-01-01
A pressure-sensitive film was used to characterize the asperity contacts along a polymethyl methacrylate (PMMA) interface in the laboratory. The film has structural health monitoring (SHM) applications for flanges and other precision fittings and train rail condition monitoring. To calibrate the film, simple spherical indentation tests were performed and validated against a finite element model (FEM) to compare normal stress profiles. Experimental measurements of the normal stress profiles were within −7.7% to 6.6% of the numerical calculations between 12 and 50 MPa asperity normal stress. The film also possessed the capability of quantifying surface roughness, an important parameter when examining wear and attrition in SHM applications. A high definition video camera supplied data for photometric analysis (i.e., the measure of visible light) of asperities along the PMMA-PMMA interface in a direct shear configuration, taking advantage of the transparent nature of the sample material. Normal stress over individual asperities, calculated with the pressure-sensitive film, was compared to the light intensity transmitted through the interface. We found that the luminous intensity transmitted through individual asperities linearly increased 0.05643 ± 0.0012 candelas for an increase of 1 MPa in normal stress between normal stresses ranging from 23 to 33 MPa. PMID:25923930
A Conservative Inverse Normal Test Procedure for Combining P-Values in Integrative Research.
ERIC Educational Resources Information Center
Saner, Hilary
1994-01-01
The use of p-values in combining results of studies often involves studies that are potentially aberrant. This paper proposes a combined test that permits trimming some of the extreme p-values. The trimmed statistic is based on an inverse cumulative normal transformation of the ordered p-values. (SLD)
Modeling the Impact of Value of Information on Situational Awareness using C3TRACE
2016-05-01
ARL-TR-7684 ● MAY 2016 US Army Research Laboratory Modeling the Impact of Value of Information on Situational Awareness Using...US Army Research Laboratory Modeling the Impact of Value of Information on Situational Awareness using C3TRACE by John T Richardson...SUBTITLE Modeling the Impact of Value of Information on Situational Awareness Using C3TRACE 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM
Thompson, Jess L; Sundt, Thoralf M; Sarano, Maurice E; Santrach, Paula J; Schaff, Hartzell V
2008-06-01
Patient self-testing of the international normalized ratio (INR) has been shown to improve management of anticoagulation with warfarin and reduce risks of thromboembolism and bleeding. Self-testing instruction usually begins several weeks after hospital discharge. We evaluated the feasibility of in-hospital INR self-testing instruction in patients recovering from valve replacement. We instituted an education program on a self-testing device before hospital discharge in 50 adult patients (median age, 54 years; 66% men) undergoing cardiac valve replacement with mechanical prostheses. Patients were monitored for 1 month to assess their ability to self-test and the accuracy of the INR measurements. Self-testing instruction began on postoperative day 4 (range, 1 to 8 days). Each patient had an average of 3.5 teaching sessions; each session lasted approximately 20 minutes. One month after discharge, all patients (98%) but 1 were able to self-test. No patient required interval instruction. One bleeding episode occurred in a patient whose INR exceeded the therapeutic range. Once warfarin doses were stabilized, 5 patients had subtherapeutic INR values on self-testing. The mean INR test result obtained from the coagulometer correlated well with values obtained by laboratory determination (r = 0.79). This evaluation of an in-hospital education program demonstrates that patients are able to learn INR self-testing and that most will continue to use the method without the need for interval instruction. Improved anticoagulation management by early introduction of INR self-testing should reduce thromboembolic and hemorrhagic complications after valve replacement.
Normalization is a general neural mechanism for context-dependent decision making
Louie, Kenway; Khaw, Mel W.; Glimcher, Paul W.
2013-01-01
Understanding the neural code is critical to linking brain and behavior. In sensory systems, divisive normalization seems to be a canonical neural computation, observed in areas ranging from retina to cortex and mediating processes including contrast adaptation, surround suppression, visual attention, and multisensory integration. Recent electrophysiological studies have extended these insights beyond the sensory domain, demonstrating an analogous algorithm for the value signals that guide decision making, but the effects of normalization on choice behavior are unknown. Here, we show that choice models using normalization generate significant (and classically irrational) choice phenomena driven by either the value or number of alternative options. In value-guided choice experiments, both monkey and human choosers show novel context-dependent behavior consistent with normalization. These findings suggest that the neural mechanism of value coding critically influences stochastic choice behavior and provide a generalizable quantitative framework for examining context effects in decision making. PMID:23530203
Liu, Jianhua; Yu, Xiaojun; Xia, Meng; Cai, Hong; Cheng, Guixue; Wu, Lina; Li, Qiang; Zhang, Ying; Sheng, Mengyuan; Liu, Yong; Qin, Xiaosong
2017-04-01
A laboratory- and region-specific trimester-related reference interval for thyroid hormone assessment of pregnant women was recommended. Whether the division by trimester is suitable requires verification. Here, we tried to establish appropriate reference intervals of thyroid-related hormones and antibodies for normal pregnant women in Northeast China. A total of 947 pregnant women who underwent routine prenatal care were grouped via two methods. The first method entailed division by trimester: stages T1, T2, and T3. The second method entailed dividing T1, T2, and T3 stages into two stages each: T1-1, T1-2, T2-1, T2-2, T3-1, and T3-2. Serum levels of TSH, FT3, FT4, Anti-TPO, and Anti-TG were measured by three detection systems. No significant differences were found in TSH values between T1-1 group and the non-pregnant women group. However, the TSH value of the T1-1 group was significantly higher than that of T1-2 group (P<0.05). The TSH values in stage T3-2 increased significantly compared to those in stage T3-1 measured by three different assays (P<0.05). FT4 and FT3 values decreased significantly in the T2-1 and T2-2 stages compared to the previous stage (P<0.05). The serum levels of Anti-TPO and Anti-TG were not having significant differences between the six stages. The diagnosis and treatment of thyroid dysfunction during pregnancy should base on pregnancy- and method-specific reference intervals. More detailed staging is required to assess the thyroid function of pregnant women before 20 gestational weeks. Copyright © 2016 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Blackshear, J L; Baker, V S; Holland, A; Litin, S C; Ahlquist, D A; Hart, R G; Ellefson, R; Koehler, J
1996-03-25
Antithrombotic prophylaxis using combined aspirin and low-dose warfarin is under evaluation in several clinical trials. However, therapy may result in increased gastrointestinal blood loss and clinical bleeding vs conventional single-agent antithrombotic therapy. To assess differences in gastrointestinal blood loss, we measured quantitative fecal hemoglobin equivalents (HemoQuant, Mayo Medical Laboratory, Rochester, Minn) in 117 patients, mean age 71 years, 1 month after initiation of assigned therapy in the Stroke Prevention in Atrial Fibrillation III Study. Sixty-three of these patients who had characteristics for high risk of stroke were randomly assigned to conventional adjusted-dose warfarin therapy (international normalized ratio, 2.0 to 3.0) or low-dose combined therapy (warfarin [international normalization ratio,<1.5] plus 325 mg/d of enteric-coated aspirin). The remaining 54 patients with low risk of stroke received 325 mg/d of enteric-coated aspirin. Among the 63 at high risk of stroke, abnormal values (>2mg of hemoglobin per gram of stool) were detected in 11% and values greater than 4 mg of hemoglobin per gram of stool were found in 8%. Mean ( +/- SD) values were more for those randomly assigned to receive combined therapy (1.7 +/- 3.3 mg of hemoglobin per gram of stool vs adjusted-dose warfarin therapy, 1.0 +/- 1.9 mg/g; P=.003). The 54 nonrandomized patients with low risk of stroke receiving aspirin alone had a mean (+/- SD) HemoQuant value of 0.8 +/- 0.7mg of hemoglobin per gram of stool 1 month after entry in the study. Abnormal levels of fecal hemoglobin excretion were common in elderly patients with high risk of atrial fibrillation 1 month after randomization to prophylactic antithrombotic therapy. Combined warfarin and aspirin therapy was associated with greater fecal hemoglobin excretion than standard warfarin therapy, suggesting the potential for increased gastrointestinal hemorrhage.
NASA Astrophysics Data System (ADS)
PAN, X.; Kanaya, Y.; Taketani, F.; Miyakawa, T.; Inomata, S.; Komazaki, Y.; Tanimoto, H.; Uno, I.; Wang, Z.
2014-12-01
Open biomass burning (OBB) experiments were performed in the laboratory environment to investigate the mixing state of refractory black carbon (rBC) in fresh smoke and its dependence on combustion state. A Single-Particle Soot Photometer (SP2) was adopted to measure variation of number size distribution of rBC-containing particles in high temporal resolution. General combustion state of each OBB case was indicated by modified combustion efficiency (MCE) using accumulated enhancement of mixing ratios of carbon dioxide and carbon monoxide during the experiments. We found that mass equivalent diameter (MED) of rBC increased apparently with increase of MCE values, indicating the flaming-dominant combustion tend to produce the rBC particles with relative larger size, probably because of coagulation processes in high concentration condition. Coating thickness of rBC-containing particle was calculated by leading edge only fitting (LEO-fitting) method. In the present study we defined the rBC-containing particles with shell/core (S/C) ratio larger than 2 as "thickly coated" and that less then 1.5 as "thinly coated". As a result, thickly coated rBC particles normally had a relatively small core (MED of rBC less than 150 nm) and its number fraction showed an evident decrease as a function of MCE value, whereas, larger rBC particles (MED larger than 150 nm) were normally thinly coated. Number fraction of both thinly coated and uncoated rBC particles had an positive correlation with MCE value. Substantial amount of light scattering particles (LSP) observed in the smoldering-dominant OBB plumes could partially explain the increase of number fraction of coated rBC particles. ΔrBC/ΔCO ratio showed a good positive correlation with MCE with an average value of 16.8 (1.2 - 51.6) ng/m3/ppbv, and ΔrBC/ΔCO2 ratio was found 628.7 ng/m3/ppmv, generally consistent with previous studies.
Lin, Wen-Li; Chi, Hsin; Huang, Fu-Yuan; Huang, Daniel Tsung-Ning; Chiu, Nan-Chang
2016-10-01
Cerebrospinal fluid (CSF) cell count and biochemical examinations and cultures form the basis for the diagnosis of bacterial meningitis. However, some patients do not have typical findings and are at a higher risk of being missed or having delayed treatment. To better understand the correlation between CSF results and outcomes, we evaluated CSF data focusing on the patients with atypical findings. This study enrolled CSF culture-proven bacterial meningitis patients aged from 1 month to 18 years in a medical center. The patients were divided into "normal" and "abnormal" groups for each laboratory result and in combination. The correlations between the laboratory results and the outcomes were analyzed. A total of 175 children with confirmed bacterial meningitis were enrolled. In CSF examinations, 16.2% of patients had normal white blood cell counts, 29.5% had normal glucose levels, 24.5% had normal protein levels, 10.2% had normal results in two items, and 8.6% had normal results in all three items. In logistic regression analysis, a normal CSF leukocyte count and increased CSF protein level were related to poor outcomes. Patients with meningitis caused by Streptococcus pneumoniae and hyponatremia were at a higher risk of mortality and the development of sequelae. In children with bacterial meningitis, nontypical CSF findings and, in particular, normal CSF leukocyte count and increased protein level may indicate a worse prognosis. Copyright © 2014. Published by Elsevier B.V.
NASA Technical Reports Server (NTRS)
Torr, D. G.; Orsini, N.
1978-01-01
The Atmosphere Explorer (AE) data are reexamined in the light of new laboratory measurements of the N2(+) recombination rate coefficient alpha. The new measurements support earlier measurements which yielded values of alpha significantly lower than the AE values. It is found that the values for alpha determined from the satellite data can be reconciled with the laboratory measurements, if the charge exchange rate coefficient for O(+)(2D) with N2 is less than one-quarter of that derived in the laboratory by Rutherford and Vroom (1971).
Thermo-optical vacuum testing of IRNSS laser retroreflector array qualification model
NASA Astrophysics Data System (ADS)
Porcelli, L.; Boni, A.; Ciocci, E.; Contessa, S.; Dell'Agnello, S.; Delle Monache, G.; Intaglietta, N.; Martini, M.; Mondaini, C.; Patrizi, G.; Salvatori, L.; Tibuzzi, M.; Lops, C.; Cantone, C.; Tuscano, P.; Maiello, M.; Venkateswaran, R.; Chakraborty, P.; Ramana Reddy, C. V.; Sriram, K. V.
2017-09-01
We describe the activities performed by SCF_Lab (Satellite/lunar/GNSS laser ranging/altimetry and cube/microsat Characterization Facilities Laboratory) of INFN-LNF for the thermo-optical vacuum testing activity of a IRNSS (Indian Regional Navigation Satellite System) LRA (Laser Retroreflector Array), under contract for ISRO-LEOS. To our knowledge, this is the first publication on the characterization of the optical performance of an LRA operating at about 36,000 km altitude (typical of regional GNSS segments, namely QZSS, COMPASS-G) executed in fully representative, carefully lab-simulated space conditions. In particular, this is the only such publication concerning IRNSS. Since laser ranging to its altitude is more challenging than to GNSS altitudes (from about 19,100 km for GLONASS to about 23,200 km for Galileo), comparative measurements were long awaited by ILRS (International Laser Ranging Service) and we present measurements of the absolute laser return to ground stations of the ILRS in terms of lidar OCS (Optical Cross Section) at the IRNSS relevant value of velocity aberration, in turn derived from measurements of the full FFDP (Far Field Diffraction Pattern) over a very large range of velocity aberrations. These measurements were acquired: (i) on a full-size qualification model of a IRNSS CCR (Cube Corner Retroreflector) LRA that ISRO-LEOS provided to INFN-LNF; (ii) during the lab-simulation of a 1/4 orbit segment, in which the LRA CCRs are exposed to the perturbation of the sun heat at varying angles, from grazing incidence (90° with respect to the direction perpendicular to the plane of array), up to the perpendicular to the LRA, with a same time variation consistent with the actual space orbit. In this 1/4 orbit condition, the LRA experiences potentially large thermal degradations of the OCS, depending on the detailed thermal and mechanical design of the LRA. Since all GNSS constellations have different LRA designs or configurations, this is another reason of the interest in the laboratory optical performance of the IRNSS designs. In fact, we tested two different IRNSS LRA configurations, without and with an auxiliary cover. The latter of the configurations is designed to give a somewhat increased performance. We also measured FFDPs and OCS: (1) in-air isothermal conditions (thus obtaining the LRA nominal performance); (2) in space conditions at a low, stationary value of the LRA bulk temperature; (3) in space conditions at a high, stationary value of the LRA bulk temperature (Figs. S1-S18, available in the online supplementary material for this paper). In all these three cases, we measured FFDPs and OCS at the following laser incidence angles: (a) normal to the LRA plane; (b) +9° to the normal to the LRA plane; (c) -9° to the normal to the LRA plane. This is the first time, to our knowledge, that the measurements (not simulations) at ±9° (values requested by ISRO-LEOS) are published for GNSS LRAs. Finally, we point out that we measured full-FFDP and OCS of single CCRs, for maximum diagnostic value and performance validation at subelement level. For all these reasons, the articulate and variate set of tests of the IRNSS LRA reported in this paper is unique.
The value-added laboratory: an opportunity to merge research and service objectives.
McDonald, J M
1997-01-01
The changing health-care environment is creating a new opportunities for laboratory medicine professionals that correspond with the new health services research agendas. Proving cost-effectiveness and conducting outcomes assessment are becoming vital functions of laboratories in this era of managed care. Laboratorians must take advantage of the resulting opportunities to show how they add value and medical relevance to the health-care delivery system.
Stress drop with constant, scale independent seismic efficiency and overshoot
Beeler, N.M.
2001-01-01
To model dissipated and radiated energy during earthquake stress drop, I calculate dynamic fault slip using a single degree of freedom spring-slider block and a laboratory-based static/kinetic fault strength relation with a dynamic stress drop proportional to effective normal stress. The model is scaled to earthquake size assuming a circular rupture; stiffness varies inversely with rupture radius, and rupture duration is proportional to radius. Calculated seismic efficiency, the ratio of radiated to total energy expended during stress drop, is in good agreement with laboratory and field observations. Predicted overshoot, a measure of how much the static stress drop exceeds the dynamic stress drop, is higher than previously published laboratory and seismic observations and fully elasto-dynamic calculations. Seismic efficiency and overshoot are constant, independent of normal stress and scale. Calculated variation of apparent stress with seismic moment resembles the observational constraints of McGarr [1999].
Safety assessment characteristics of pedestrian legform impactors in vehicle-front impact tests.
Matsui, Yasuhiro
2014-12-01
This study investigated the characteristics of safety assessment results of front-area vehicle impact tests carried out using the Transport Research Laboratory (TRL) legform impactor and a flexible legform impactor (FLEX legform impactor). Different types of vehicles (sedan, sport utility vehicle, high-roof K-car, and light cargo van) were examined. The impact locations in the study were the center of the bumper and an extremely stiff structure of the bumper (i.e., in front of the side member) of each tested vehicle. The measured injury criteria were normalized by injury assessment reference values of each legform impactor. The test results for center and side-member impacts indicated that there were no significant differences in ligament injury assessments derived from the normalized knee ligament injury measures between the TRL legform impactor and the FLEX legform impactor. Evaluations made using the TRL legform impactor and the FLEX legform impactor are thus similar in the vehicle safety investigation for knee ligament injury. Vehicle-center impact test results revealed that the tibia fracture assessments derived from the normalized tibia fracture measures did not significantly differ between the TRL legform impactor and the FLEX legform impactor. However, for an impact against an extremely stiff structure, there was a difference in the tibia fracture assessment between the FLEX legform impactor and the TRL legform impactor owing to their different sensor types. Copyright © 2014 Elsevier Ltd. All rights reserved.
Miller, R F; Fox, J D; Thomas, P; Waite, J C; Sharvell, Y; Gazzard, B G; Harrison, M J; Brink, N S
1996-01-01
OBJECTIVES: To describe the abnormalities in CSF from HIV infected patients with acute lumbosacral polyradiculopathy (ALP) caused by cytomegalovirus (CMV) infection. METHODS: Retrospective case notes and laboratory records were reviewed for 17 consecutive patients with CMV associated ALP admitted to specialist HIV/AIDS units at UCL Hospitals and Chelsea and Westminster Hospital. RESULTS: Infection with CMV was confirmed by detection of CMV DNA by polymerase chain reaction amplification in 15 patients (all of whom were negative by culture), by culture in one patient, and by objective clinical response to anti-CMV treatment in one patient. Only nine patients had a CSF pleocytosis 28-1142 (median 150) cells/mm3; in seven there was a polymorphonuclear (PMN) leucocyte preponderance. Protein concentrations in CSF were moderately or considerably raised in 13 patients; CSF: plasma glucose ratios were < or = 50% in five patients. Two patients had no pleocytosis, normal CSF: plasma glucose, and normal or near normal protein values. CONCLUSIONS: Abnormalities in CSF in CMV associated ALP are varied: only 50% of patients have a "typical" PMN preponderant pleocytosis. The diagnosis of this condition should not rely on demonstration of a PMN preponderant pleocytosis, but on identification of CMV DNA in CSF and the exclusion of other opportunistic infections and lymphoma in order that specific anti-CMV treatment may be instituted. PMID:8937337
Nocoń-Bohusz, Julita; Wikiera, Beata; Basiak, Aleksander; Śmigiel, Robert; Noczyńska, Anna
2016-02-18
Severe hypertriglyceridemia is a condition associated with extremely high triglycerides (TG) plasma concentrations exceeding 1000mg/dl. This condition may result in mutations in genes encoding lipoprotein lipase (LPL), apolipoprotein C2 (APOC2) and apolipoprotein A5 (APOA5) characterized by an autosomal recessive inheritance pattern. A case report of a patient in which clinical picture of type 1 diabetes mellitus (T1DM) was accompanied by diabetic ketoacidosis (DKA) and severe hypertriglyceridemia. A 2.5-year-old boy was admitted to the hospital with ketoacidosis (pH - 7.0, BE - 20mmol/l, HCO3 10mmol/l), glucose level of 850mg%, hyponatremia (Na 100mmol/l) and hyperlipidemia (TG 13493 mg/dl, TC 734 mg/dl). The administered treatment resulted in nearly normal glycemic values and lipid disturbances normalization. This child was diagnosed with a heterozygous mutation of the LPL gene. Currently with an intensive insulin therapy and correct metabolic control of type 1 diabetes mellitus (T1DM), this patient maintains a normal lipid profile. In patient with T1DM the diagnosis of severe hypertriglyceridemia in the course of ketoacidosis should be based on careful interpretation of laboratory tests results. Moreover genetic tests of the patient and his/her immediate relatives blood samples should be performed. © Polish Society for Pediatric Endocrinology and Diabetology.
Abnormal pulmonary function in adults with sickle cell anemia.
Klings, Elizabeth S; Wyszynski, Diego F; Nolan, Vikki G; Steinberg, Martin H
2006-06-01
Pulmonary complications of sickle cell anemia (Hb-SS) commonly cause morbidity, yet few large studies of pulmonary function tests (PFTs) in this population have been reported. PFTs (spirometry, lung volumes, and diffusion capacity for carbon monoxide [DLCO]) from 310 adults with Hb-SS were analyzed to determine the pattern of pulmonary dysfunction and their association with other systemic complications of sickle cell disease. Raw PFT data were compared with predicted values. Each subject was subclassified into one of five groups: obstructive physiology, restrictive physiology, mixed obstructive/restrictive physiology, isolated low DLCO, or normal. The association between laboratory data of patients with decreased DLCO or restrictive physiology and those of normal subjects was assessed by multivariate linear regression. Normal PFTs were present in only 31 of 310 (10%) patients. Overall, adults with Hb-SS were characterized by decreased total lung capacities (70.2 +/- 14.7% predicted) and DLCO (64.5 +/- 19.9%). The most common PFT patterns were restrictive physiology (74%) and isolated low DLCO (13%). Decreased DLCO was associated with thrombocytosis (p = 0.05), with hepatic dysfunction (elevated alanine aminotransferase; p = 0.07), and a trend toward renal dysfunction (elevated blood urea nitrogen and creatinine; p = 0.05 and 0.07, respectively). Pulmonary function is abnormal in 90% of adult patients with Hb-SS. Common abnormalities include restrictive physiology and decreased DLCO. Decreased DLCO may indicate more severe sickle vasculopathy characterized by impaired hepatic and renal function.
Normalizing Catastrophe: An Educational Response
ERIC Educational Resources Information Center
Jickling, Bob
2013-01-01
Processes of normalizing assumptions and values have been the subjects of theoretical framing and critique for several decades now. Critique has often been tied to issues of environmental sustainability and social justice. Now, in an era of global warming, there is a rising concern that the results of normalizing of present values could be…
Evaluation of Kurtosis into the product of two normally distributed variables
NASA Astrophysics Data System (ADS)
Oliveira, Amílcar; Oliveira, Teresa; Seijas-Macías, Antonio
2016-06-01
Kurtosis (κ) is any measure of the "peakedness" of a distribution of a real-valued random variable. We study the evolution of the Kurtosis for the product of two normally distributed variables. Product of two normal variables is a very common problem for some areas of study, like, physics, economics, psychology, … Normal variables have a constant value for kurtosis (κ = 3), independently of the value of the two parameters: mean and variance. In fact, the excess kurtosis is defined as κ- 3 and the Normal Distribution Kurtosis is zero. The product of two normally distributed variables is a function of the parameters of the two variables and the correlation between then, and the range for kurtosis is in [0, 6] for independent variables and in [0, 12] when correlation between then is allowed.
Aarsand, Aasne K; Villanger, Jørild H; Støle, Egil; Deybach, Jean-Charles; Marsden, Joanne; To-Figueras, Jordi; Badminton, Mike; Elder, George H; Sandberg, Sverre
2011-11-01
The porphyrias are a group of rare metabolic disorders whose diagnosis depends on identification of specific patterns of porphyrin precursor and porphyrin accumulation in urine, blood, and feces. Diagnostic tests for porphyria are performed by specialized laboratories in many countries. Data regarding the analytical and diagnostic performance of these laboratories are scarce. We distributed 5 sets of multispecimen samples from different porphyria patients accompanied by clinical case histories to 18-21 European specialist porphyria laboratories/centers as part of a European Porphyria Network organized external analytical and postanalytical quality assessment (EQA) program. The laboratories stated which analyses they would normally have performed given the case histories and reported results of all porphyria-related analyses available, interpretative comments, and diagnoses. Reported diagnostic strategies initially showed considerable diversity, but the number of laboratories applying adequate diagnostic strategies increased during the study period. We found an average interlaboratory CV of 50% (range 12%-152%) for analytes in absolute concentrations. Result normalization by forming ratios to the upper reference limits did not reduce this variation. Sixty-five percent of reported results were within biological variation-based analytical quality specifications. Clinical interpretation of the obtained analytical results was accurate, and most laboratories established the correct diagnosis in all distributions. Based on a case-based EQA scheme, variations were apparent in analytical and diagnostic performance between European specialist porphyria laboratories. Our findings reinforce the use of EQA schemes as an essential tool to assess both analytical and diagnostic processes and thereby to improve patient care in rare diseases.
On the frictional (in) stability of clay-bearing faults
NASA Astrophysics Data System (ADS)
Violay, M.; Orellana, F.; Scuderi, M. M.; Collettini, C.
2016-12-01
Opalinus clay (OPA) is shale rock studied under the context of deep geological disposal by The Mont Terri Laboratory research program in Switzerland. Despite its favorable hydro-mechanical properties, the presence of a large tectonic fault system intersecting the rock formation arises questions over the long-term safety performance of a nuclear waste repository, in terms of possible leakages and the possibility of earthquakes triggered by fault instability. To study the frictional stability of OPA, we have performed velocity steps (1-300 μm/s) and slide-hold-slide tests (1-10000 s) on simulated gouge and intact samples - sheared parallel and perpendicular to foliation - at different normal stresses (4 - 30 MPa). To understand the deformation mechanisms, we have analyzed the microstructures of the sheared samples trough optical and SE microscopy. Results reported peak and steady state friction values ranging from 0.21 to 0.52 and from 0.14 to 0.39 respectively. Consistently, samples with well-developed layering showed lower friction values than gouge samples even though they have the same mineralogical composition. At all normal stresses, velocity dependence tests on gouge showed a velocity strengthening regime, whereas, intact samples developed both velocity-strengthening and velocity-weakening regimes. Finally, we have recorded near zero healing values for both intact and powdered samples at different normal stress. However, a complex evolution from negative to positive frictional healing rate, with an inflexion holding time of 300 s, has been observed. In conclusion, our data suggests that both the velocity strengthening regime and the near zero healing for the simulated gouge, are consistent with aseismic creep. We have also reported the possibility of unstable sliding outside the fault core accompanied by low capacity of contact regeneration, and low capacity to sustain future stress drops compared to evidence showed by experiments on simulated gouge. Moreover, microstructure analysis revealed different deformation patterns due to anisotropy of the material. Thus, the complex frictional behavior of OPA highlights the need for further experiments in order to better evaluate the seismic risk during long-term nuclear waste disposal within the OPA clay formation.
48 CFR 215.404-71-1 - General.
Code of Federal Regulations, 2010 CFR
2010-10-01
... range provides values based on above normal or below normal conditions. In the price negotiation..., DEPARTMENT OF DEFENSE CONTRACTING METHODS AND CONTRACT TYPES CONTRACTING BY NEGOTIATION Contract Pricing 215... contracting officer assigns values to each profit factor; the value multiplied by the base results in the...
Attitudes of Healthcare Students on Gross Anatomy Laboratory Sessions
ERIC Educational Resources Information Center
Kawashiro, Yukiko; Anahara, Reiko; Kohno, Toshihiko; Mori, Chisato; Matsuno, Yoshiharu
2009-01-01
At Chiba University, gross anatomy laboratory sessions ("laboratories") are required for physical therapy students. Though most physical therapy schools require their students to participate in laboratories so that they will better understand the structure of the human body, few data exist on the value of these laboratories specifically…
Predoctoral Fellowship to Study an ER Variant Identified from Breast Hyperplasias.
1999-07-01
Spl and Sp3 in Drosophila SL2 cells, which do not express any of the Spl family members. The plasmid pNull- Renilla (Promega) was co- transfected for...10 M. Luciferase values were normalized to Renilla luciferase expression. Fold induction was calculated relative to the normalized luciferase...to 10 M. Luciferase values were normalized to Renilla luciferase expression. Fold induction was calculated relative to the normalized luciferase
The role of postictal laboratory blood analyses in the diagnosis and prognosis of seizures.
Nass, Robert D; Sassen, Robert; Elger, Christian E; Surges, Rainer
2017-04-01
Epileptic seizures (ES) lead to alterations in the blood laboratory values and reflect changes in different organ systems. Here, we review the diagnostic and prognostic value of various blood laboratory values within the context of epilepsy. Narrative review and literature search on PubMed using the term, "seizure" and various laboratory values. Laboratory markers can help clinicians determine whether an unwitnessed event was more likely to be epileptic or non-epileptic. Prolactin testing helps differentiate ES from psychogenic non-epileptic seizures (PNES) in adults and adolescents, and is associated with high specificity and moderate sensitivity. Elevations in the creatine kinase (CK) levels are common after generalized tonic-clonic seizures (GTCS) and display high specificity and moderate sensitivity. Metabolic markers such as ammonia and lactate may have diagnostic potential for postictal blood tests. Analyzing blood postictally is important for identifying the cause of the symptomatic seizures due to endocrine, metabolic, toxic or infectious etiologies. Finally, laboratory analyses are used for identifying patients who are at risk for developing rare, threatening complications such as rhabdomyolysis, acute renal failure (ARF) or cardiomyopathy. Presently, no postictal laboratory values can definitively prove or rule out the diagnosis of an epileptic seizure. For seizures with unknown causes, simple blood tests can be a valuable aid for quickly defining the etiology, particularly with certain metabolic and toxic encephalopathies. For this reason, CK, electrolytes, creatinine, liver and renal function tests should be measured on at least one occasion. Further research is needed in order to identify new biomarkers that improve the diagnosis and prognosis of seizures and seizure-related complications. Copyright © 2017 British Epilepsy Association. Published by Elsevier Ltd. All rights reserved.
The validation of the Z-Scan technique for the determination of plasma glucose
NASA Astrophysics Data System (ADS)
Alves, Sarah I.; Silva, Elaine A. O.; Costa, Simone S.; Sonego, Denise R. N.; Hallack, Maira L.; Coppini, Ornela L.; Rowies, Fernanda; Azzalis, Ligia A.; Junqueira, Virginia B. C.; Pereira, Edimar C.; Rocha, Katya C.; Fonseca, Fernando L. A.
2013-11-01
Glucose is the main energy source for the human body. The concentration of blood glucose is regulated by several hormones including both antagonists: insulin and glucagon. The quantification of glucose in the blood is used for diagnosing metabolic disorders of carbohydrates, such as diabetes, idiopathic hypoglycemia and pancreatic diseases. Currently, the methodology used for this determination is the enzymatic colorimetric with spectrophotometric. This study aimed to validate the use of measurements of nonlinear optical properties of plasma glucose via the Z-Scan technique. For this we used samples of calibrator patterns that simulate commercial samples of patients (ELITech ©). Besides calibrators, serum glucose levels within acceptable reference values (normal control serum - Brazilian Society of Clinical Pathology and Laboratory Medicine) and also overestimated (pathological control serum - Brazilian Society of Clinical Pathology and Laboratory Medicine) were used in the methodology proposal. Calibrator dilutions were performed and determined by the Z-Scan technique for the preparation of calibration curve. In conclusion, Z-Scan method can be used to determinate glucose levels in biological samples with enzymatic colorimetric reaction and also to apply the same quality control parameters used in biochemistry clinical.
Expanding sialidosis spectrum by genome-wide screening: NEU1 mutations in adult-onset myoclonus.
Canafoglia, Laura; Robbiano, Angela; Pareyson, Davide; Panzica, Ferruccio; Nanetti, Lorenzo; Giovagnoli, Anna Rita; Venerando, Anna; Gellera, Cinzia; Franceschetti, Silvana; Zara, Federico
2014-06-03
To identify the genetic cause of a familial form of late-onset action myoclonus in 2 unrelated patients. Both probands had 2 siblings displaying a similar disorder. Extensive laboratory examinations, including biochemical assessment for urine sialic acid in the 2 probands, were negative. Exome sequencing was performed in the probands using an Illumina platform. Segregation analysis of putative mutations was performed in all family members by standard Sanger sequencing protocols. NEU1 mutations were detected in 3 siblings of each family with prominent cortical myoclonus presenting in the third decade of life and having a mild and slowly progressive course. They did not have macular cherry-red spot and their urinary sialic acid excretion was within normal values. Genetic analysis demonstrated a homozygous mutation in family 1 (c.200G>T, p.S67I) and 2 compound heterozygous mutations in family 2 (c.679G>A, p.G227R; c.913C>T, p.R305C). Our observation indicates that sialidosis should be suspected and the NEU1 gene analyzed in patients with isolated action myoclonus presenting in adulthood in the absence of other typical clinical and laboratory findings. © 2014 American Academy of Neurology.
See, Randolph B.; Schroder, LeRoy J.; Willoughby, Timothy C.
1988-01-01
During 1986, the U.S. Geological Survey operated three programs to provide external quality-assurance monitoring of the National Atmospheric Deposition Program and National Trends Network. An intersite-comparison program was used to assess the accuracy of onsite pH and specific-conductance determinations at quarterly intervals. The blind-audit program was used to assess the effect of routine sample handling on the precision and bias of program and network wet-deposition data. Analytical results from four laboratories, which routinely analyze wet-deposition samples, were examined to determine if differences existed between laboratory analytical results and to provide estimates of the analytical precision of each laboratory. An average of 78 and 89 percent of the site operators participating in the intersite-comparison met the network goals for pH and specific conductance. A comparison of analytical values versus actual values for samples submitted as part of the blind-audit program indicated that analytical values were slightly but significantly (a = 0.01) larger than actual values for pH, magnesium, sodium, and sulfate; analytical values for specific conductance were slightly less than actual values. The decreased precision in the analyses of blind-audit samples when compared to interlaboratory studies indicates that a large amount of uncertainty in network deposition data may be a result of routine field operations. The results of the interlaboratory comparison study indicated that the magnitude of the difference between laboratory analyses was small for all analytes. Analyses of deionized, distilled water blanks by participating laboratories indicated that the laboratories had difficulty measuring analyte concentrations near their reported detection limits. (USGS)
Filimberti, E; Degl'Innocenti, S; Borsotti, M; Quercioli, M; Piomboni, P; Natali, I; Fino, M G; Caglieresi, C; Criscuoli, L; Gandini, L; Biggeri, A; Maggi, M; Baldi, E
2013-05-01
We report the results of the first three trials of an external quality control (EQC) programme performed in 71 laboratories executing semen analysis in Tuscany Region (Italy). At the end of the second trial, participants were invited to attend a teaching course illustrating and inviting to adhere to procedures recommended by WHO (V edition). Results of the first three trials of the EQC documented a huge variability in the procedures and the results. The highest variability was found for morphology (CV above 80% for all the trials), followed by count (CV of about 60% for all the trials) and motility (CV below 30% for all the trials). When results of sperm count and morphology were divided according to the used method, mean CV values did not show significant differences. CV for morphology dropped significantly at the third trial for most methods, indicating the usefulness of the teaching course for morphology assessment. Conversely, no differences were observed after the course for motility and for most methods to evaluate count, although CV values were lower at the second and third trial for the laboratories using the Burker cytometer. When results were divided according to tertiles of activity, the lowest mean bias values (difference between each laboratory result and the median value of the results) for count and morphology were observed for laboratories in the third tertile (performing over 200 semen analysis/year). Of interest, mean bias values for concentration dropped significantly at the third trial for low activity laboratories. In conclusion, lack of agreement of results of semen analysis in Tuscany is mainly because of the activity and the experience of the laboratory. Our study points out the importance of participating in EQC programmes and periodical teaching courses as well as the use of WHO recommended standardized procedures to increase precision and to allow the use of WHO reference values. © 2013 American Society of Andrology and European Academy of Andrology.
Randomized controlled trial of a treatment for anorexia and bulimia nervosa
Bergh, Cecilia; Brodin, Ulf; Lindberg, Greger; Södersten, Per
2002-01-01
Evidence for the effectiveness of existing treatments of patients with eating disorders is weak. Here we describe and evaluate a method of treatment in a randomized controlled trial. Sixteen patients, randomly selected out of a group composed of 19 patients with anorexia nervosa and 13 with bulimia nervosa, were trained to eat and recognize satiety by using computer support. They rested in a warm room after eating, and their physical activity was restricted. The patients in the control group (n = 16) received no treatment. Remission was defined by normal body weight (anorexia), cessation of binge eating and purging (bulimia), a normal psychiatric profile, normal laboratory test values, normal eating behavior, and resumption of social activities. Fourteen patients went into remission after a median of 14.4 months (range 4.9–26.5) of treatment, but only one patient went into remission while waiting for treatment (P = 0.0057). Relapse is considered a major problem in patients who have been treated to remission. We therefore report results on a total of 168 patients who have entered our treatment program. The estimated rate of remission was 75%, and estimated time to remission was 14.7 months (quartile range 9.6 ≥ 32). Six patients (7%) of 83 who were treated to remission relapsed, but the others (93%) have remained in remission for 12 months (quartile range 6–36). Because the risk of relapse is maximal in the first year after remission, we suggest that most patients treated with this method recover. PMID:12082182
[A case of chronic multifocal myositis].
Maruyama, T; Kondo, K; Tabata, K; Yanagisawa, N
1992-11-01
A 61-year-old civil engineer began to have slowly progressive muscle atrophy in the right shoulder and the left arm at 56 years of age. Muscle wasting became manifest in the left thigh at 59 years and in the right thigh at 60 years. He had mild difficulty in climbing and descending stairs. On examination, although he had notable muscle atrophy in the right trapezius and proximal muscles in the upper and lower extremities, his muscle strength was relatively well preserved. The muscle atrophy was asymmetrical; the right periscapular region and the left upper and lower extremities were more markedly atrophic. In addition, multiple foci of the striking muscle atrophy were noted in the upper trunk and the proximal limb muscles. Fasciculation was not present. Deep tendon reflexes were normal with no pathologic reflexes. Except for a moderately elevated serum creatine kinase level of 709 Ul/l (normal 40-170) and mildly elevated serum myoglobin level of 100 ng/ml (normal < 60), no laboratory tests showed abnormal values suggesting an inflammatory process. Motor and sensory nerve conduction velocities were within normal limits. Electromyography disclosed myopathic and neuropathic changes. Computed tomography (CT) of skeletal muscles showed asymmetrical muscle atrophy and patchy low-density foci. In biopsied left quadriceps and right gastrocnemius muscles which showed partially low density on CT, there was marked variation in muscle fiber size, with necrotic and regenerating fibers, an increased number of centrally placed nuclei, and interstitial fibrosis. There were numerous foci of mononuclear inflammatory cellular infiltration, especially around the blood vessels.(ABSTRACT TRUNCATED AT 250 WORDS)
Ng, Chaan S.; Hobbs, Brian P.; Wei, Wei; Anderson, Ella F.; Herron, Delise H.; Yao, James C.; Chandler, Adam G.
2014-01-01
Objective To assess the effects of sampling interval (SI) of CT perfusion acquisitions on CT perfusion values in normal liver and liver metastases from neuroendocrine tumors. Methods CT perfusion in 16 patients with neuroendocrine liver metastases were analyzed by distributed parameter modeling to yield tissue blood flow, blood volume, mean transit time, permeability, and hepatic arterial fraction, for tumor and normal liver. CT perfusion values for the reference sampling interval of 0.5s (SI0.5) were compared with those of SI datasets of 1s, 2s, 3s and 4s, using mixed-effects model analyses. Results Increases in SI beyond 1s were associated with significant and increasing departures of CT perfusion parameters from reference values at SI0.5 (p≤0.0009). CT perfusion values deviated from reference with increasing uncertainty with increasing SIs. Findings for normal liver were concordant. Conclusion Increasing SIs beyond 1s yield significantly different CT perfusion parameter values compared to reference values at SI0.5. PMID:25626401
Karadeli, Elif; Erbay, Gurcan; Parlakgumus, Alper; Koc, Zafer
2018-02-01
To determine the feasibility of diffusion-weighted imaging in evaluation of pancreatic lesions and in differentiation of benign from malignant lesions. Descriptive study. Baskent University Adana Teaching and Research Center, Adana, Turkey, between September 2013 and May 2015. Forty-three lesions [pancreas adenocarcinoma (n=25)], pancreatitis (n=10), benign lesion (n=8)] were utilized with diffusion-weighted magnetic resonance imaging with multiple b-values. Different ADC maps of diffusion weighted images by using b-values were acquired. The median ADC at all b values for malignant lesions was significantly different from that for benign lesions (p<0.001). When ADCs at all b values were compared between benign lesions/normal parenchyma and malignant lesions/normal parenchyma, there was a significant statistical difference in all b values between benign and malignant lesions except at b 50 and b 200 (p<0.05). The lesion/normal parenchyma ADC ratio for b 600 value (AUC=0.804) was more effective than the lesion ADC for b 600 value (AUC=0.766) in differentiation of benign and malignant lesions. The specificity and sensitivity of the lesion/normal parenchyma ADC ratio were higher than those of ADC values of lesions. When the ADC was compared between benign lesions and pancreatitis, a significant difference was found at all b values (p<0.001). There was not a statistically significant difference between the ADC for pancreatitis and that for malignant lesions at any b value combinations (p>0.05). Diffusion-weighted magnetic resonance images can be helpful in differentiation of pancreatic carcinoma and benign lesions. Lesion ADC / normal parenchyma ADC ratios are more important than lesion ADC values in assessment of pancreatic lesions.
Opportune Landing Site CBR and Low-Density Laboratory Database
2008-05-01
Program Opportune Landing Site CBR and Low- Density Laboratory Database Larry S. Danyluk, Sally A. Shoop, Rosa T. Affleck, and Wendy L. Wieder...Opportune Landing Site Program ERDC/CRREL TR-08-9 May 2008 Opportune Landing Site CBR and Low- Density Laboratory Database Larry S. Danyluk, Sally A...reproduce in-situ density , moisture, and CBR values and therefore do not accurately repre- sent the complete range of these values measured in the field
Follow-up on the effects of the space environment on UHCRE thermal blankets
NASA Technical Reports Server (NTRS)
Levadou, Francois; Vaneesbeek, Marc
1993-01-01
An overview of the effects of the space environment on the thermal blanket of the UHCRE experiment is presented with an emphasis on atomic oxygen (AO) erosion. A more accurate value for FEP Teflon reaction efficiency is given and corresponds, at normal incidence, to 3.24 10(exp -25) cu cm/atomic, therefore, the FEP Teflon erosion corresponding to the Long Duration Exposure Facility (LDEF) total mission is 29.5 microns. A power 1.44 of the cosine of the incident angle of the oxygen atoms is found. It is shown that this value is not far from the power found using Fergusson's relationship between efficiency and energy of the O-atoms. An hypothesis concerning the effect of oxygen ions (O(+)) is also presented. The presence of oxygen ions may explain the different results obtained from different flights and from laboratory tests. Finally an XPS analysis of Chemglaze Z306(tm) black paint demonstrates the presence of silicone in the paint which may explain part of the contamination found on LDEF.
The contribution of light Majorana neutrinos to neutrinoless double beta decay and cosmology
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dell'Oro, S.; Marcocci, S.; Viel, M.
Cosmology is making impressive progress and it is producing stringent bounds on the sum of the neutrino masses Σ, a parameter of great importance for the current laboratory experiments. In this letter, we exploit the potential relevance of the analysis of Palanque-Delabrouille et al. [JCAP 02 (2015) 045] to the neutrinoless double beta decay (0ν β β) search. This analysis indicates small values for the lightest neutrino mass, since the authors find Σ < 84 meV at 1σ C.L., and provides a 1σ preference for the normal hierarchy. The allowed values for the Majorana effective mass, probed by 0ν β β, turn out to be < 75more » meV at 3σ C.L. and lower down to less than 02 meV at 1σ C.L. . If this indication is confirmed, the impact on the 0ν β β experiments will be tremendous since the possibility of detecting a signal will be out of the reach of the next generation of experiments.« less
The contribution of light Majorana neutrinos to neutrinoless double beta decay and cosmology
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dell’Oro, S.; Marcocci, S.; Viel, M.
Cosmology is making impressive progress and it is producing stringent bounds on the sum of the neutrino masses Σ, a parameter of great importance for the current laboratory experiments. In this letter, we exploit the potential relevance of the analysis of Palanque-Delabrouille et al. to the neutrinoless double beta decay (0νββ) search. This analysis indicates small values for the lightest neutrino mass, since the authors find Σ<84 meV at 1σ C.L., and provides a 1σ preference for the normal hierarchy. The allowed values for the Majorana effective mass, probed by 0νββ, turn out to be <75 meV at 3σ C.L.more » and lower down to less than 20 meV at 1σ C.L. . If this indication is confirmed, the impact on the 0νββ experiments will be tremendous since the possibility of detecting a signal will be out of the reach of the next generation of experiments.« less
Salivary cortisol and cortisone in the clinical setting.
Blair, Joanne; Adaway, Jo; Keevil, Brian; Ross, Richard
2017-06-01
A resurgence of interest in salivary biomarkers has generated evidence for their value in assessing adrenal function. The advantages of salivary measurements include only free hormone is detected, samples can be collected during normal daily routines and stress-induced cortisol release is less likely to occur than during venepuncture. We review the use of salivary biomarkers to diagnose and monitor patients for conditions of cortisol excess and deficiency and discuss the value of measuring salivary cortisone versus salivary cortisol. Developments in laboratory techniques have enabled the measurement of salivary hormones with a high level of sensitivity and specificity. In states of altered cortisol binding, salivary biomarkers are more accurate measures of adrenal reserve than serum cortisol. Salivary cortisone is a superior marker of serum cortisol compared with salivary cortisol, specifically when serum cortisol is low and during hydrocortisone therapy when contamination of saliva may result in misleading salivary cortisol concentrations. Salivary cortisol and cortisone can be used to assess cortisol excess, deficiency and hydrocortisone replacement, with salivary cortisone having the advantage of detection when serum cortisol levels are low and there is no interference from oral hydrocortisone.
Effect of soil texture on the microwave emission from soils
NASA Technical Reports Server (NTRS)
Schmugge, T. J.
1980-01-01
The intensity brightness temperature of the microwave emission from the soil is determined primarily by its dielectric properties. The large difference between the dielectric constant of water and that of dry soil produces a strong dependence of the soil's dielectric constant on its moisture content. This dependence is effected by the texture of the soil because the water molecules close to the particle surface are tightly bound and do not contribute significantly to the dielectric properties. Since this surface area is a function of the particle size distribution (soil texture), being larger for clay soils with small particles, and smaller for sandy soils with larger particles; the dielectric properties will depend on soil texture. Laboratory measurements of the dielectric constant for soils are summarized. The dependence of the microwave emission on texture is demonstrated by measurements of brightness temperature from an aircraft platform for a wide range of soil textures. It is concluded that the effect of soil texture differences on the observed values can be normalized by expressing the soil moisture values as a percent field capacity for the soil.
7 CFR 760.5 - Fair market value of milk.
Code of Federal Regulations, 2010 CFR
2010-01-01
... market value of the affected farmer's normal marketings, which, for the purposes of this subpart, shall be the sum of the net proceeds such farmer would have received for his normal marketings in each of... affected farmer's normal marketings for each such pay period by the average net price per hundred-weight of...
Transient hyperphosphatemia: a benign laboratory disorder in a boy with Gitelman syndrome.
Skalova, Sylva; Kutilek, Stepan
2016-01-01
Transient hyperphosphatasemia of infancy and early childhood (THI) is characterized by transiently increased activity of serum alkaline phosphatase (S-ALP), predominantly its bone or liver isoform, in children under five years of age. There are no signs of metabolic bone disease or hepatopathy corresponding with the increased S-ALP. THI is benign disorder, rather laboratory than clinical disorder, which is usually accidentally detected in both healthy and sick children. When encountered in a child with either chronic bone, liver or kidney disease, it might concern the physician. We present a three year old boy with genetically confirmed Gitelman syndrome where THI was detected accidentally during periodic check-up. S-ALP peaked to 41.8 µkat/L, there were neither laboratory or clinical signs of liver or bone disease; the S-ALP dropped to normal value of 4 µkat/L 60 days later. Therefore, the patient fulfilled the criteria for THI. There were no further increases in S-ALP. Resumo A hiperfosfatasemia transitória benigna da infância (HTBI) é caracterizada por elevação transitória da atividade da fosfatase alcalina sérica (S-ALP), predominantemente em sua isoforma óssea ou hepática, em crianças com menos de cinco anos de idade. Não há sinais de patologia óssea metabólica ou hepatopatia correspondentes ao aumento da S-ALP. A HTBI é um distúrbio benigno, mais laboratorial que clínico, normalmente detectado acidentalmente em crianças saudáveis e acometidas por alguma patologia. Quando encontrada em crianças com doença crônica óssea, hepática ou renal, maiores preocupações são justificadas. O presente relato descreve o caso de um menino de três anos de idade com síndrome de Gitelman geneticamente confirmada, em que a HTBI foi detectada acidentalmente durante um exame periódico. A S-ALP atingiu o pico de 41,8 µkat/L, sem sinais laboratoriais ou clínicos de doença hepática ou óssea. O valor de S-ALP caiu para o nível normal de 4 µkat/L 60 dias mais tarde. Portanto, o paciente satisfazia os critérios para HTBI. Não houve outros aumentos na S-ALP.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chandra, R.; Pierno, C.; Braunstein, P.
1978-09-01
Desferal was labeled with /sup 111/In and its distribution was studied in normal mice, rabbits bearing turpentine-induced abscesses, and rats bearing Staphyloccus aureus-induced abscesses. The results indicate that /sup 111/In Desferal may be used in abscess detection and localization.
The Pea Seedling as a Model of Normal and Abnormal Morphogenesis
ERIC Educational Resources Information Center
Kurkdjian, Armen; And Others
1974-01-01
Describes several simple and inexpensive experiments designed to facilitate the study of normal and abnormal morphogenesis in the biology laboratory. Seedlings of the common garden pea are used in the experiments, and abnormal morphogenesis (tumors) are induced by a virulent strain of the crown-gall organism, Agrobacterium tumefaciens. (JR)
ERIC Educational Resources Information Center
Jiao, Li; Xiujuan, Shi; Juan, Wang; Song, Jia; Lei, Xu; Guotong, Xu; Lixia, Lu
2015-01-01
For second year medical students, we redesigned an original laboratory experiment and developed a combined research-teaching clinical biochemistry experiment. Using an established diabetic rat model to detect blood glucose and triglycerides, the students participate in the entire experimental process, which is not normally experienced during a…
Male characteristics on female mud snails caused by antifouling bottom paints.
Smith, B S
1981-02-01
This study continues an investigation of an anatomical abnormality, named 'imposex', which consists of a superimposition of male characteristics on to a functionally normal female reproductive anatomy of the dioecious snail Nassarius obsoletus Say. Imposex is prevalent in natural populations living near yacht basins and rarely found distant from them. In the current study caged snails were transferred between a yacht basin and a distant 'clean' locality where the natural population of snails was normal. Imposex was induced in some normal snails kept at the marina and suppressed, but not lost in abnormal snails kept at the clean locality. A similar positive result was obtained in the laboratory by exposing normal snails to organotin-containing antifouling paints and abnormal snails to clean sea water. Results were negative in parallel tests of various marina-associated materials which did not contain organotin. The laboratory studies have thus identified a causative factor for the anatomical abnormalities common near yacht basins in the natural environment. They also provide a rare, if not unique, example of a chemical agent which causes the appearance of superfluous anatomical features in an animal.
Measuring the glycemic index of foods: interlaboratory study.
Wolever, Thomas M S; Brand-Miller, Jennie C; Abernethy, John; Astrup, Arne; Atkinson, Fiona; Axelsen, Mette; Björck, Inger; Brighenti, Furio; Brown, Rachel; Brynes, Audrey; Casiraghi, M Cristina; Cazaubiel, Murielle; Dahlqvist, Linda; Delport, Elizabeth; Denyer, Gareth S; Erba, Daniela; Frost, Gary; Granfeldt, Yvonne; Hampton, Shelagh; Hart, Valerie A; Hätönen, Katja A; Henry, C Jeya; Hertzler, Steve; Hull, Sarah; Jerling, Johann; Johnston, Kelly L; Lightowler, Helen; Mann, Neil; Morgan, Linda; Panlasigui, Leonora N; Pelkman, Christine; Perry, Tracy; Pfeiffer, Andreas F H; Pieters, Marlien; Ramdath, D Dan; Ramsingh, Rayna T; Robert, S Daniel; Robinson, Carol; Sarkkinen, Essi; Scazzina, Francesca; Sison, Dave Clark D; Sloth, Birgitte; Staniforth, Jane; Tapola, Niina; Valsta, Liisa M; Verkooijen, Inge; Weickert, Martin O; Weseler, Antje R; Wilkie, Paul; Zhang, Jian
2008-01-01
Many laboratories offer glycemic index (GI) services. We assessed the performance of the method used to measure GI. The GI of cheese-puffs and fruit-leather (centrally provided) was measured in 28 laboratories (n=311 subjects) by using the FAO/WHO method. The laboratories reported the results of their calculations and sent the raw data for recalculation centrally. Values for the incremental area under the curve (AUC) reported by 54% of the laboratories differed from central calculations. Because of this and other differences in data analysis, 19% of reported food GI values differed by >5 units from those calculated centrally. GI values in individual subjects were unrelated to age, sex, ethnicity, body mass index, or AUC but were negatively related to within-individual variation (P=0.033) expressed as the CV of the AUC for repeated reference food tests (refCV). The between-laboratory GI values (mean+/-SD) for cheese-puffs and fruit-leather were 74.3+/-10.5 and 33.2+/-7.2, respectively. The mean laboratory GI was related to refCV (P=0.003) and the type of restrictions on alcohol consumption before the test (P=0.006, r2=0.509 for model). The within-laboratory SD of GI was related to refCV (P<0.001), the glucose analysis method (P=0.010), whether glucose measures were duplicated (P=0.008), and restrictions on dinner the night before (P=0.013, r2=0.810 for model). The between-laboratory SD of the GI values is approximately 9. Standardized data analysis and low within-subject variation (refCV<30%) are required for accuracy. The results suggest that common misconceptions exist about which factors do and do not need to be controlled to improve precision. Controlled studies and cost-benefit analyses are needed to optimize GI methodology. The trial was registered at clinicaltrials.gov as NCT00260858.
19 CFR 351.404 - Selection of the market to be used as the basis for normal value.
Code of Federal Regulations, 2010 CFR
2010-04-01
... value. (a) Introduction. Although in most circumstances sales of the foreign like product in the home... market if the Secretary is satisfied that sales of the foreign like product in that country are of... use of sales to a third country or constructed value as the basis for normal value. This section...
Rousset, Sylvie; Fardet, Anthony; Lacomme, Philippe; Normand, Sylvie; Montaurier, Christophe; Boirie, Yves; Morio, Béatrice
2015-01-01
The objective of this study was to evaluate the validity of total energy expenditure (TEE) provided by Actiheart and Armband. Normal-weight adult volunteers wore both devices either for 17 hours in a calorimetric chamber (CC, n = 49) or for 10 days in free-living conditions (FLC) outside the laboratory (n = 41). The two devices and indirect calorimetry or doubly labelled water, respectively, were used to estimate TEE in the CC group and FLC group. In the CC, the relative value of TEE error was not significant (p > 0.05) for Actiheart but significantly different from zero for Armband, showing TEE underestimation (-4.9%, p < 0.0001). However, the mean absolute values of errors were significantly different between Actiheart and Armband: 8.6% and 6.7%, respectively (p = 0.05). Armband was more accurate for estimating TEE during sleeping, rest, recovery periods and sitting-standing. Actiheart provided better estimation during step and walking. In FLC, no significant error in relative value was detected. Nevertheless, Armband produced smaller errors in absolute value than Actiheart (8.6% vs. 12.8%). The distributions of differences were more scattered around the means, suggesting a higher inter-individual variability in TEE estimated by Actiheart than by Armband. Our results show that both monitors are appropriate for estimating TEE. Armband is more effective than Actiheart at the individual level for daily light-intensity activities.
Developing Normal Turns-Amplitude Clouds for Upper and Lower Limbs.
Jabre, Joe F; Nikolayev, Sergey G; Babayev, Michael B; Chindilov, Denis V; Muravyov, Anatoly Y
2016-10-01
Turns and amplitude analysis (T&A) is a frequently used method for automatic EMG interference pattern analysis. The T&A normal values have only been developed for a limited number of muscles. Our objective was to obtain normal T&A clouds for upper and lower extremity muscles for which no normal values exist in the literature. The T&A normative data using concentric needle electrodes were obtained from 68 men and 56 women aged 20 to 60 years. Normal upper and lower extremity T&A clouds were obtained and presented in this article. The T&A normal values collected in this study maybe used to detect neurogenic and myopathic abnormalities in men and women at low-to-moderate muscle contractions. The effect of turns-amplitude data obtained at high force level of muscle contraction and its potential to falsely show neurogenic abnormalities are discussed.
Peplies, J; Jiménez-Pavón, D; Savva, S C; Buck, C; Günther, K; Fraterman, A; Russo, P; Iacoviello, L; Veidebaum, T; Tornaritis, M; De Henauw, S; Mårild, S; Molnár, D; Moreno, L A; Ahrens, W
2014-09-01
The aim of this study is to present age- and sex-specific reference values of insulin, glucose, glycosylated haemoglobin (HbA1c) and the homeostasis model assessment to quantify insulin resistance (HOMA-IR) for pre-pubertal children. The reference population consists of 7074 normal weight 3- to 10.9-year-old pre-pubertal children from eight European countries who participated in at least one wave of the IDEFICS ('identification and prevention of dietary- and lifestyle-induced health effects in children and infants') surveys (2007-2010) and for whom standardised laboratory measurements were obtained. Percentile curves of insulin (measured by an electrochemiluminescence immunoassay), glucose, HbA1c and HOMA-IR were calculated as a function of age stratified by sex using the general additive model for location scale and shape (GAMLSS) method. Levels of insulin, fasting glucose and HOMA-IR continuously show an increasing trend with age, whereas HbA1c shows an upward trend only beyond the age of 8 years. Insulin and HOMA-IR values are higher in girls of all age groups, whereas glucose values are slightly higher in boys. Median serum levels of insulin range from 17.4 and 13.2 pmol l(-1) in 3-<3.5-year-old girls and boys, respectively, to 53.5 and 43.0 pmol l(-1) in 10.5-<11-year-old girls and boys. Median values of glucose are 4.3 and 4.5 mmol l(-1) in the youngest age group and 49.3 and 50.6 mmol l(-1) in the oldest girls and boys. For HOMA-IR, median values range from 0.5 and 0.4 in 3-<3.5-year-old girls and boys to 1.7 and 1.4 in 10.5-<11-year-old girls and boys, respectively. Our study provides the first standardised reference values for an international European children's population and provides the, up to now, largest data set of healthy pre-pubertal children to model reference percentiles for markers of insulin resistance. Our cohort shows higher values of Hb1Ac as compared with a single Swedish study while our percentiles for the other glucose metabolic markers are in good accordance with previous studies.
Hemoglobin A1c can be helpful in predicting progression to diabetes after Whipple procedure.
Hamilton, Lisa; Jeyarajah, D Rohan
2007-01-01
Normoglycemic patients undergoing pancreaticoduodenectomy (Whipple procedure) often inquire whether they will be diabetic postoperatively. There is limited information on this issue. We therefore looked at a more subtle measurement of long-term glycemic control, hemoglobin A1c (HgbA1c), as a prognostic tool in predicting progression to diabetes post Whipple. A retrospective review over a 6-year period of all patients undergoing Whipple procedures at a single institution was conducted. In all, 27 patients had no prior history of diabetes, complete follow-up, and measured preoperative HgbA1c values. Postoperative diabetes was defined as the need for oral hypoglycemic agents or insulin. These charts were analyzed for progression to diabetes after Whipple. Of the 27 patients, 10 were considered to have postoperative diabetes. The average preoperative HgbA1c value for these patients was 6.3+/-0.66. This was statistically different from the 17 patients without postoperative diabetes (average HgbA1c 5.2+/-0.39, p<0.001). The positive predictive value, negative predictive value, sensitivity, and specificity were 82%, 94%, 90%, and 88%, respectively. This study demonstrates that progression to diabetes is very unlikely after Whipple operation if the preoperative HgbA1c value is in the normal range. The apparent utility of HgbA1c in predicting postoperative diabetes in this small study suggests that this laboratory test may be very helpful in counseling patients for Whipple operation.
Zhao, Hai-Jian; Zhang, Tian-Jiao; Zeng, Jie; Hu, Cui-Hua; Ma, Rong; Zhang, Chuan-Bao
2017-01-01
Background: Hemoglobin A1c (HbA1c) measurement is of great value for the diagnosis and monitoring of diabetes. Many manufacturers have developed various experiments to determine the HbA1c concentration. However, the longitudinal use of these tests requires strict quality management. This study aimed to analyze the quality of HbA1c measurement systems in China using six sigma techniques to help improve their performances. Methods: A total of 135 laboratories were involved in this investigation in 2015. Bias values and coefficients of variation were collected from an HbA1c trueness verification external quality assessment program and an internal quality control program organized by the National Center of Clinical Laboratories in China. The sigma (σ) values and the quality goal index (QGI) were used to evaluate the performances of different groups, which were divided according to principles and instruments. Results: The majority of participants (88, 65.2%) were scored as “improvement needed (σ < 3)”, suggesting that the laboratories needed to improve their measurement performance. Only 8.2% (11/135) of the laboratories were scored as “world class (σ ≥ 6)”. Among all the 88 laboratories whose σ values were below 3, 52 (59.1%) and 23 (26.1%) laboratories needed to improve measurement precision (QGI <8.0) and trueness (QGI >1.2), respectively; the remaining laboratories (13, 14.8%) needed to improve both measurement precision and trueness. In addition, 16.1% (5/31) and 15.0% (3/20) of the laboratories in “TOSOH” and “ARKRAY” groups, respectively, were scored as “world class”, whereas none of the laboratories in “BIO-RAD” group were scored as “world class”. Conclusions: This study indicated that, although participating laboratories were laboratories with better performance in China, the performances were still unsatisfactory. Actions should be taken to improve HbA1c measurement performance before we can include HbA1c assays in diabetes diagnosis in China. PMID:28469104
High ferritin levels have major effects on the morphology of erythrocytes in Alzheimer's disease.
Bester, Janette; Buys, Antoinette V; Lipinski, Boguslaw; Kell, Douglas B; Pretorius, Etheresia
2013-01-01
Unliganded iron both contributes to the pathology of Alzheimer's disease (AD) and also changes the morphology of erythrocytes (RBCs). We tested the hypothesis that these two facts might be linked, i.e., that the RBCs of AD individuals have a variant morphology, that might have diagnostic or prognostic value. We included a literature survey of AD and its relationships to the vascular system, followed by a laboratory study. Four different microscopy techniques were used and results statistically compared to analyze trends between high and normal serum ferritin (SF) AD individuals. Light and scanning electron microscopies showed little difference between the morphologies of RBCs taken from healthy individuals and from normal SF AD individuals. By contrast, there were substantial changes in the morphology of RBCs taken from high SF AD individuals. These differences were also observed using confocal microscopy and as a significantly greater membrane stiffness (measured using force-distance curves). We argue that high ferritin levels may contribute to an accelerated pathology in AD. Our findings reinforce the importance of (unliganded) iron in AD, and suggest the possibility both of an early diagnosis and some means of treating or slowing down the progress of this disease.
Application of a system for measuring foot plantar pressure for evaluation of human mobility
NASA Astrophysics Data System (ADS)
Klimiec, Ewa; Jasiewicz, Barbara; Zaraska, Krzysztof; Piekarski, Jacek; Guzdek, Piotr; Kołaszczyński, Grzegorz
2016-11-01
The paper presents evaluation of human mobility by gait analysis, carried out in natural conditions (outside laboratory). Foot plantar pressure is measured using a shoe insole with 8 sensors placed in different anatomical zones of the foot, and placed inside a sports footwear. Polarized PVDF foil is used as a sensor material. A wireless transmission system is used to transmit voltage values to the computer. Due to linear relationship between force and transducer voltage, energy released during walking in arbitrary units can be calculated as integral of the square of transducer voltage over time. Gait measurements have been done over the next few days on healthy person during normal walking and slow walking. Performed measurements allow determination of walking speed (number of steps per second), gait rhythm and manner of walking (applying force to inside versus outside part of the sole). It is found that switching from normal to slow walk increases gait energy by 25% while the pressure distribution across the anatomical regions of the foot remains unchanged. The results will be used for developing a programme for evaluation of patients with cardiac failure and future integration of actimetry with pulse and spirometry measurements.
Resveratrol and polydatin as modulators of Ca2+ mobilization in the cardiovascular system.
Liu, Wenjuan; Chen, Peiya; Deng, Jianxin; Lv, Jingzhang; Liu, Jie
2017-09-01
In the cardiovascular system, Ca 2+ controls cardiac excitation-contraction coupling and vascular contraction and dilation. Disturbances in intracellular Ca 2+ homeostasis induce malfunctions of the cardiovascular system, including cardiac pump dysfunction, arrhythmia, remodeling, and apoptosis, as well as hypertension and impairment of vascular reactivity. Therefore, developing drugs and strategies manipulating Ca 2+ handling are highly valued in the treatment of cardiovascular disease. Resveratrol (Res) and polydatin (PD), a Res glucoside, have been well established to have beneficial effects on improving cardiovascular function. Studies from our laboratory and others have demonstrated that they exhibit inotropic effects on normal heart and therapeutic effects on hypertension, cardiac ischemia/reperfusion injury, hypertrophy, and heart failure by manipulating Ca 2+ mobilization. The actions of Res and PD on Ca 2+ signals delicately manipulated by multiple Ca 2+ -handling proteins are pleiotropic and somewhat controversial, depending on cellular species and intracellular oxidative status. Here, we focus on the effects of Res and PD on controlling Ca 2+ homeostasis in the heart and vasculature under normal and diseased conditions and highlight the key direct and indirect molecules mediating these effects. © 2017 New York Academy of Sciences.
Treviso, Felipe; Silveira, Marilia A.; Flores Filho, Aly F.; Dorrell, David G.
2016-01-01
This paper presents a study on an induction planar actuator concept. The device uses the same principles as a linear induction motor in which the interaction between a travelling magnetic field and a conducting surface produces eddy currents that leads to the generation of a thrust force and can result in movement over a metallic surface. This can benefit the inspection of metallic surfaces based on the driving platform provided by the induction planar actuator. Equations of the magnetic and electric fields are presented and, by means of these equations, the forces involved were calculated. The behaviour of thrust and normal forces was analysed through the equations and by numerical models, and compared with the results obtained by measurements on a device prototype built in the laboratory as part of the study. With relation to the surface under inspection that forms the secondary, three cases were analysed: (1) a double-layered secondary formed by aluminium and ferromagnetic slabs; (2) a single aluminium layer and (3) a single ferromagnetic layer. Theoretical and measured values of thrust and normal forces showed good correlation. PMID:27007377
[Results of a dynamic study on the status of health and nutrition of a Siberian vegan settlement].
Medkova, I L; Mosiakina, L I; Biriukova, L S
2001-01-01
In 1996 for the first time a study of state of health, living conditions and nutrition status of 84 persons from the Siberian settlement of the rigorous vegetarians--vegans and 26 aboriginal inhabitants who feed on a traditional mixed diet was carried out. The clinical and laboratory investigations are kept. The positive influencing vegan ration on a serum lipids, body weight, state of cardiovascular system was showed. The contents of vitamin B12 and serum iron in vegans was in normal physiological range. The level of blood calcium was reduced in comparison with control. Increased contents of copper and zinc in blood was marked both in vegans and in control group. The repeated examination of 77 vegans of the same settlement in 1999 has revealed positive alterations in serum lipids: augmentation of cholesterol of high density lipoproteins on the average on 54.3%, that result in a reliable decrease of atherogenicity coefficient. The decrease to normal amounts of blood copper and zinc, and also increase of blood calcium on the average on 16% was marked. However level of calcium remained below than physiological values.
Correlation of Respirator Fit Measured on Human Subjects and a Static Advanced Headform
Bergman, Michael S.; He, Xinjian; Joseph, Michael E.; Zhuang, Ziqing; Heimbuch, Brian K.; Shaffer, Ronald E.; Choe, Melanie; Wander, Joseph D.
2015-01-01
This study assessed the correlation of N95 filtering face-piece respirator (FFR) fit between a Static Advanced Headform (StAH) and 10 human test subjects. Quantitative fit evaluations were performed on test subjects who made three visits to the laboratory. On each visit, one fit evaluation was performed on eight different FFRs of various model/size variations. Additionally, subject breathing patterns were recorded. Each fit evaluation comprised three two-minute exercises: “Normal Breathing,” “Deep Breathing,” and again “Normal Breathing.” The overall test fit factors (FF) for human tests were recorded. The same respirator samples were later mounted on the StAH and the overall test manikin fit factors (MFF) were assessed utilizing the recorded human breathing patterns. Linear regression was performed on the mean log10-transformed FF and MFF values to assess the relationship between the values obtained from humans and the StAH. This is the first study to report a positive correlation of respirator fit between a headform and test subjects. The linear regression by respirator resulted in R2 = 0.95, indicating a strong linear correlation between FF and MFF. For all respirators the geometric mean (GM) FF values were consistently higher than those of the GM MFF. For 50% of respirators, GM FF and GM MFF values were significantly different between humans and the StAH. For data grouped by subject/respirator combinations, the linear regression resulted in R2 = 0.49. A weaker correlation (R2 = 0.11) was found using only data paired by subject/respirator combination where both the test subject and StAH had passed a real-time leak check before performing the fit evaluation. For six respirators, the difference in passing rates between the StAH and humans was < 20%, while two respirators showed a difference of 29% and 43%. For data by test subject, GM FF and GM MFF values were significantly different for 40% of the subjects. Overall, the advanced headform system has potential for assessing fit for some N95 FFR model/sizes. PMID:25265037
Gondim Teixeira, Pedro Augusto; Leplat, Christophe; Chen, Bailiang; De Verbizier, Jacques; Beaumont, Marine; Badr, Sammy; Cotten, Anne; Blum, Alain
2017-12-01
To evaluate intra-tumour and striated muscle T1 value heterogeneity and the influence of different methods of T1 estimation on the variability of quantitative perfusion parameters. Eighty-two patients with a histologically confirmed musculoskeletal tumour were prospectively included in this study and, with ethics committee approval, underwent contrast-enhanced MR perfusion and T1 mapping. T1 value variations in viable tumour areas and in normal-appearing striated muscle were assessed. In 20 cases, normal muscle perfusion parameters were calculated using three different methods: signal based and gadolinium concentration based on fixed and variable T1 values. Tumour and normal muscle T1 values were significantly different (p = 0.0008). T1 value heterogeneity was higher in tumours than in normal muscle (variation of 19.8% versus 13%). The T1 estimation method had a considerable influence on the variability of perfusion parameters. Fixed T1 values yielded higher coefficients of variation than variable T1 values (mean 109.6 ± 41.8% and 58.3 ± 14.1% respectively). Area under the curve was the least variable parameter (36%). T1 values in musculoskeletal tumours are significantly different and more heterogeneous than normal muscle. Patient-specific T1 estimation is needed for direct inter-patient comparison of perfusion parameters. • T1 value variation in musculoskeletal tumours is considerable. • T1 values in muscle and tumours are significantly different. • Patient-specific T1 estimation is needed for comparison of inter-patient perfusion parameters. • Technical variation is higher in permeability than semiquantitative perfusion parameters.
Meier, Frederick A; Badrick, Tony C; Sikaris, Kenneth A
2018-02-17
For 50 years, structure, process, and outcomes measures have assessed health care quality. For clinical laboratories, structural quality has generally been assessed by inspection. For assessing process, quality indicators (QIs), statistical monitors of steps in the clinical laboratory total testing, have proliferated across the globe. Connections between structural and process laboratory measures and patient outcomes, however, have rarely been demonstrated. To inform further development of clinical laboratory quality systems, we conducted a selective but worldwide review of publications on clinical laboratory quality assessment. Some QIs, like seven generic College of American Pathologists Q-Tracks monitors, have demonstrated significant process improvement; other measures have uncovered critical opportunities to improve test selection and result management. The College of Pathologists of Australasia Key Indicator Monitoring and Management System has deployed risk calculations, introduced from failure mode effects analysis, as surrogate measures for outcomes. Showing economic value from clinical laboratory testing quality is a challenge. Clinical laboratories should converge on fewer (7-14) rather than more (21-35) process monitors; monitors should cover all steps of the testing process under laboratory control and include especially high-risk specimen-quality QIs. Clinical laboratory stewardship, the combination of education interventions among clinician test orderers and report consumers with revision of test order formats and result reporting schemes, improves test ordering, but improving result reception is more difficult. Risk calculation reorders the importance of quality monitors by balancing three probabilities: defect frequency, weight of potential harm, and detection difficulty. The triple approach of (1) a more focused suite of generic consensus quality indicators, (2) more active clinical laboratory testing stewardship, and (3) integration of formal risk assessment, rather than competing with economic value, enhances it.
Stepman, Hedwig C M; Stöckl, Dietmar; Acheme, Rosana; Sesini, Sandra; Mazziotta, Daniel; Thienpont, Linda M
2011-11-01
The Fundación Bioquímica Argentina (FBA) performs external quality assessment (EQA) of >3200 laboratories. However, FBA realizes that sample non-commutability and predominant use of heterogeneous systems may bias the estimated performance and standardization status. To eliminate these confounding factors, a study using frozen single donation sera was undertaken with the focus on serum-calcium and -albumin measurement. Target values were established from the results produced with homogeneous systems. In groups of n=7, system effects were investigated. Laboratory performance was evaluated from the correlation coefficient r between the measurement results for all sera and the target values. This allowed ranking of the laboratories and judgment of the deviation for individual samples (total error) against a 10% limit. The total error specification was a deviation for ≥ 5 samples exceeding 10% and/or causing a result outside the laboratory's reference interval. For calcium (n=303) (range: 2.06-2.42 mmol/L), 81 laboratories had an r-value <0.6, 43 even <0.4; the total error was relevant for 97 (10% limit) and 111 (reference interval) laboratories. For albumin (n=311) (range: 34.7-45.7 g/L) r was <0.7 (<0.4) in 44 (16) laboratories; 83 and 36 laboratories exceeded the total error criteria. Laboratories using homogeneous systems were generally ranked higher by correlation. System effects were moderate for calcium, but significant for albumin. The study demonstrated the need to improve the quality and harmonization of calcium and albumin testing in the investigated laboratories. To achieve this objective, we promote co-operation between laboratories, EQA provider and manufacturers.
Crytzer, Theresa M; Keramati, Mariam; Anthony, Steven J; Cheng, Yu-Ting; Robertson, Robert J; Dicianno, Brad E
2018-02-03
People with spina bifida (SB) face personal and environmental barriers to exercise that contribute to physical inactivity, obesity, risk of cardiovascular disease, and poor aerobic fitness. The WHEEL rating of perceived exertion (RPE) Scale was validated in people with SB to monitor exercise intensity. However, the psycho-physiological link between RPE and ventilatory breakpoint (Vpt), the group-normalized perceptual response, has not been determined and would provide a starting point for aerobic exercise in this cohort. The primary objectives were to determine the group-normalized RPE equivalent to Vpt based on WHEEL and Borg Scale ratings and to develop a regression model to predict Borg Scale (conditional metric) from WHEEL Scale (criterion metric). The secondary objective was to create a table of interchangeable values between WHEEL and Borg Scale RPE for people with SB performing a load incremental stress test. Cross-sectional observational. University laboratory. Twenty-nine participants with SB. Participants completed a load incremented arm ergometer exercise stress test. WHEEL and Borg Scale ratings were recorded the last 15 seconds of each 1-minute test phase. WHEEL and Borg Scale ratings, metabolic measures (eg, oxygen consumption, carbon dioxide production). Determined Vpt via plots of oxygen consumption and carbon dioxide production against time. Nineteen of 29 participants achieved Vpt (Group A). The mean ± standard deviation peak oxygen consumption at Vpt for Group A was 61.76 ± 16.26. The WHEEL and Borg Scale RPE at Vpt were 5.74 ± 2.58 (range 0-10) and 13.95 ± 3.50 (range 6-19), respectively. A significant linear regression model was developed (Borg Scale rating = 1.22 × WHEEL Scale rating + 7.14) and used to create a WHEEL-to-Borg Scale RPE conversion table. A significant linear regression model and table of interchangeable values was developed for participants with SB. The group-normalized RPE (WHEEL, 5.74; Borg, 13.95) can be used to prescribe and self-regulate arm ergometer exercise intensity approximating the Vpt. II. Copyright © 2018. Published by Elsevier Inc.
NASA Astrophysics Data System (ADS)
Ijiri, K.
In the second International Microgravity Laboratory (IML-2) mission in 1994, four small Japanese killifish (Medaka, Oryzias latipes) made a space travel of 15 days aboard a space shuttle. These four adult Medaka fish successfully mated in space for the first time among vertebrate animals. Moreover, the eggs they laid developed normally, at least in their external appearance, hatching as fry (baby fish) in space. Fish mated and laid eggs every day during the first week. Near the end of the mission most of the eggs had a well-developed body with two pigmented eyes. In total, 43 eggs were laid (detected), out of which 8 fry hatched in space, as truly `space-originated' babies. A further 30 fry hatched within 3 days after landing. This is the normal hatching rate, compared with the ground-based data. Among the 8 space-originated fry, four were killed for histological sections, and germ cells at the gonadal region were counted for each fry. Their numbers were in the range of the germ cells of the normal control fry (ground-kept samples). Thus, as embryos developed normally in their external appearance, inside the embryos the formation of primordial germ cells took place normally in space, and their migration to the genital ridges was not hindered by microgravity. The two of the remaining space-originated fry have grown up and been creating their offspring in the laboratory. This proved that the primordial germ cells formed in space were also normal from a functional point of view. The four space-travelled adult fish re-started mating and laying eggs on the 7th day after landing and continued to do so every day afterward. Fertilization rate and hatchability of these eggs were as high as the eggs laid by the laboratory-kept fish. This fact implies that in gametogenesis of adult fish, there are no specific stages of germ cells extremely susceptible to microgravity.
F.M. Sauer
1956-01-01
Comparisons are made between Ignition energies of forest fuels, including newspaper, determined during Operations BUSTER, SNAPPER and UPSHOT-KNOTHOLE and laboratory exposures made utilizing the Forest Service thermal source. Agreement is excellent for fuels exposed normal to the radiant flux when fuel moisture content is considered. Ignition of fuels exposed at...
Testing Plastic Deformations of Materials in the Introductory Undergraduate Mechanics Laboratory
ERIC Educational Resources Information Center
Romo-Kroger, C. M.
2012-01-01
Normally, a mechanics laboratory at the undergraduate level includes an experiment to verify compliance with Hooke's law in materials, such as a steel spring and an elastic rubber band. Stress-strain curves are found for these elements. Compression in elastic bands is practically impossible to achieve due to flaccidity. A typical experiment for…
ERIC Educational Resources Information Center
Twomey, Patrick; O'Sullivan, Colm; O'Riordan, John
2009-01-01
A simple undergraduate experiment designed to study cooling purely by radiation and cooling by a combination of convection and radiation is described. Results indicate that the contribution from radiative cooling in normal laboratory experiments is more significant than students often realize, even in the case of forced cooling. (Contains 1…
MODELS AND METHODS IN PRACTICAL BIOLOGY FOR SECONDARY SCHOOLS.
ERIC Educational Resources Information Center
BELFIELD, W.
THIS BOOK WAS WRITTEN TO FUNCTION AS A STUDENT LABORATORY MANUAL OR AS TEACHER RESOURCE MATERIAL FOR DEVELOPING A LABORATORY-CENTERED COURSE IN PRACTICAL BIOLOGY FOR STUDENTS IN THE 13-16 AGE GROUP. IT WAS DESIGNED TO SUPPLY A COMPREHENSIVE SET OF EXPERIMENTS WHICH, WHEN CARRIED OUT IN CONJUNCTION WITH NORMAL THEORETICAL AND ANATOMICAL STUDIES,…
Marketing skills for hospital-based laboratory managers in a managed care environment.
Marchwinski, J; Coggins, F
1997-01-01
Managers of hospital-based laboratories have begun to realize the importance of a successful outreach program in protecting against declining inpatient activity. Succeeding in the highly competitive field of outpatient testing requires some new skills and techniques that may not have been apparent when addressing normal inpatient requirements. This article provides an overview of some very basic marketing concepts and attempts to show how they can assist the hospital-based laboratory manager in developing a successful outreach program.
Health fair screening: the clinical utility of the comprehensive metabolic profile.
Alpert, Jeffrey P; Greiner, Allen; Hall, Sandra
2004-01-01
Health fairs are a common method used by providers and health care organizations to provide screening tests, including comprehensive metabolic profiles (CMPs), to asymptomatic individuals. No national organizations currently recommend the complete CMP as a screening test for asymptomatic individuals in primary care settings. This study evaluated the value of CMPs in a health fair setting by measuring the ability of a health fair CMP to predict new medical diagnoses among residents of a sparsely populated rural county. Volunteer participants submitted fasting blood samples at a health fair conducted by a county health center in a county with 2,531 total residents. CMP values were determined to be "normal" or "abnormal" based on laboratory reference ranges and clinical judgment of the health center physicians. Medical records were reviewed 4 months later to determine if participants with abnormal CMP values had been diagnosed with new medical conditions as a result of the screening tests. Analysis was conducted to evaluate CMP test characteristics and determine whether demographic factors or specific CMP values predicted new medical diagnoses in the participants. Out of 478 health fair participants, 73 individuals had at least one abnormal CMP value. The most frequently occurring abnormal value was an elevated glucose level, with Hispanic participants significantly more likely to have this abnormality than whites. After all evaluation was completed, only about 1% of tested subjects had a new diagnosis as a result of the screening CMP test; most abnormal CMP tests did not result in a new diagnosis. The positive predictive value for an abnormal test resulting in a new medical diagnosis was 0.356. Comprehensive metabolic profiles have limited value as a screening tool in asymptomatic populations at health fairs.
Yamaguchi, T; Abe, S; Rompré, P H; Manzini, C; Lavigne, G J
2012-01-01
Clinicians and investigators need a simple and reliable recording device to diagnose or monitor sleep bruxism (SB). The aim of this study was to compare recordings made with an ambulatory electromyographic telemetry recorder (TEL-EMG) with those made with standard sleep laboratory polysomnography with synchronised audio-visual recording (PSG-AV). Eight volunteer subjects without current history of tooth grinding spent one night in a sleep laboratory. Simultaneous bilateral masseter EMG recordings were made with a TEL-EMG and standard PSG. All types of oromotor activity and rhythmic masseter muscle activity (RMMA), typical of SB, were independently scored by two individuals. Correlation and intra-class coefficient (ICC) were estimated for scores on each system. The TEL-EMG was highly sensitive to detect RMMA (0·988), but with low positive predictive value (0·231) because of a high rate of oromotor activity detection (e.g. swallowing and scratching). Almost 72% of false-positive oromotor activity scored with the TEL-EMG occurred during the transient wake period of sleep. A non-significant correlation between recording systems was found (r = 0·49). Because of the high frequency of wake periods during sleep, ICC was low (0·47), and the removal of the influence of wake periods improved the detection reliability of the TEL-EMG (ICC = 0·88). The TEL-EMG is sensitive to detect RMMA in normal subjects. However, it obtained a high rate of false-positive detections because of the presence of frequent oromotor activities and transient wake periods of sleep. New algorithms are needed to improve the validity of TEL-EMG recordings. © 2011 Blackwell Publishing Ltd.
Cho, Sun-Mi; Lee, Sang-Guk; Kim, Ho Seong; Kim, Jeong-Ho
2014-12-01
Defining pediatric reference intervals is one of the most difficult tasks for laboratory physicians. The continuously changing physiology of growing children makes their laboratory values moving targets. In addition, ethnic and behavioral differences might also cause variations. The aim of this study was to establish age- and sex-specific partitioned reference intervals for 13 serum biochemical analytes in Korean children. A total of 2474 patients, girls aged 2-14 years and boys aged 2-16 years, who underwent a short stature workup but were diagnosed as normal at the Pediatric Endocrinology Clinic of Severance Hospital (Seoul, Korea) between September 2010 and June 2012 were included in this study. The levels of serum calcium, inorganic phosphorus, blood urea nitrogen, creatinine, uric acid, glucose, total cholesterol, total protein, albumin, alkaline phosphatase, aspartic aminotransferase, alanine aminotransferase, and total bilirubin were measured using a Hitachi 7600 analyzer (Hitachi High-Technologies Corporation, Tokyo, Japan). Reference intervals were partitioned according to sex or age subgroups using the Harris and Boyd method. Most analytes except calcium and albumin required partitioning either by sex or age. Age-specific partitioned reference intervals for alkaline phosphatase, creatinine, and total bilirubin were established for both males and females after being partitioned by sex. Additional age-specific partitioning of aspartic aminotransferase in females and total protein and uric acid in males was also required. Inorganic phosphorus, total cholesterol, alanine aminotransferase, blood urea nitrogen, and glucose were partitioned only by sex. This study provided updated age- and sex-specific pediatric reference intervals for 13 basic serum chemistry analytes from a sufficient number of healthy children by using a modern analytical chemistry platform. Copyright © 2014 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Martin, J; Schuster, T; Moessmer, G; Kochs, E F; Wagner, K J
2012-10-01
Thromboelastometry as point-of-care (POC) testing enables the analysis of the clotting process at the bedside, providing rapid results to guide haemostatic therapy. However, POC testing utilizes medical staff who are managing critically ill patients, as non-laboratory personnel may not be sufficiently trained to run the devices. To resolve these problems, thromboelastometry can be performed in the central laboratory and rapid transport of samples can be accomplished via a pneumatic tube system (PTS). This study compares thromboelastometry parameters of blood samples analysed immediately with those analysed after PTS transport. In patients with normal haemostasis, two arterial blood samples were collected from each patient (n=92) in citrated plastic tubes to investigate the assays INTEM (n=35), EXTEM (n=27), and FIBTEM (n=30). One blood sample was analysed immediately, the other sample after PTS transport. Thromboelastometry was performed using a single ROTEM(®) device. The mean clot firmness values were significantly lower for PTS samples in both the INTEM (-0.7 mm cf. -1.1 mm) and EXTEM (-1.4 cf. -1.7 mm) assays. INTEM coagulation time (CT) was significantly lower in PTS samples with a mean difference of -13 s. EXTEM CT was significantly higher in PTS samples with a mean difference of +3.9 s. Thromboelastometry parameters of blood samples analysed after PTS transport are significantly altered compared with those analysed immediately. However, in patients with normal haemostasis, the alterations were small and without clinical consequence, implying that analysis after PTS transport is an acceptable alternative to prompt analysis at the bedside. Further studies should focus on patients with impaired haemostasis.
Factors Influencing Time-to-diagnosis of Biliary Atresia.
Harpavat, Sanjiv; Lupo, Philip J; Liwanag, Loriel; Hollier, John; Brandt, Mary L; Finegold, Milton J; Shneider, Benjamin L
2018-06-01
Diagnosing biliary atresia (BA) quickly is critical, because earlier treatment correlates with delayed or reduced need for liver transplantation. However, diagnosing BA quickly is also difficult, with infants usually treated after 60 days of life. In this study, we aim to accelerate BA diagnosis and treatment, by better understanding factors influencing the diagnostic timeline. Infants born between 2007 and 2014 and diagnosed with BA at our institution were included (n = 65). Two periods were examined retrospectively: P1, the time from birth to specialist referral, and P2, the time from specialist referral to treatment. How sociodemographic factors associate with P1 and P2 were analyzed with Kaplan-Meier curves and Cox proportional hazard models. In addition, to better characterize P2, laboratory results and early tissue histology were studied. P1 associated with race/ethnicity, with shorter times in non-Hispanic white infants compared to non-Hispanic black and Hispanic infants (P = 0.007 and P = 0.004, respectively). P2 associated with referral age, with shorter times in infants referred after 30, 45, or 60 days of life (P < 0.001, P < 0.001, and P = 0.001, respectively). One potential reason for longer P2 in infants referred ≤30 days is that aminotransferase levels were normal or near-normal. However, despite reassuring laboratory values, tissue histology in early cases showed key features of BA. Our findings suggest 2 opportunities to accelerate BA diagnosis and treatment. First, to achieve prompt referrals for all races/ethnicities, universal screening strategies should be considered. Second, to ensure efficient evaluations independent of age, algorithms designed to detect early features of BA can be developed.
MPPT implementation for the outdoor characterization of CPV modules
NASA Astrophysics Data System (ADS)
Sánchez, Daniel; Mora, Jaime; Calvo-Parra, Gustavo; Martínez, María
2015-09-01
One of the challenges during the characterization of CPV modules is to deal with the thermal behavior. During normal operation in the field the concentrator is connected to the inverter and a fraction of the energy coming from the sun is dissipated with the corresponding conversion into electricity. On the other hand, when making the characterization of CPV modules, they are usually kept in VOC between I-V sweeps, what means that none energy is converted into electricity resulting in a higher operation temperature. Current standards, like IEC-62108:2007 and IEC-62670-3 C01 draft, define that, during the outdoor characterization, the CPV module should be connected to an electrical load to maintain it near MPP between I-V sweeps, what simulates normal operating conditions. The easiest solution could be to use mini-inverters, but it is an expensive solution and not easily adaptable to the different technologies. ISFOC has designed and developed a low-cost MPPT equipment that can be easily implemented in an outdoor characterization laboratory. This equipment is compatible with most of the CPV technologies since it covers a wide range of voltage and current values (up to 150V and 10A) and it is able to distinguish between absolute and local MPP what permits working with modules in any phase of development or making shading effects measurements. Currently, the MPPT is implemented and in operation at ISFOC's outdoor laboratory to make the long term validation. But the results obtained up to now are very promising; the equipment is able to maintain the CPV module under test within a ±3% of the expected power in stable conditions and is able to keep tracking the MPP after any variation in the operating conditions, like cloudy periods, tracking incidence, shading, etc.
NASA Astrophysics Data System (ADS)
Shibghatallah, Muhammad Abdul Hakim; Khotimah, Siti Nurul; Suhandono, Sony; Viridi, Sparisoma; Kesuma, Teja
2013-09-01
Leaf colors of a plant can be used to identify stress level due to its adaptation to environmental change. For most leaves green-related colors are sourced from chlorophyll a and b. Chlorophyll concentration is normally measured using a spectrophotometer in laboratory. In some remote observation places, it is impossible to collect the leaves, preserve them, and bring them to laboratory to measure their chlorophyll content. Based on this need, measurement of chlorophyll content is observed through its color. Using CIE chromaticity diagram leaf_color information in RGB is transformed into wavelength (in nm). Paddy seed with variety name IR-64 is used in observation during its vegetation stage t (age of 0-10 days). Light exposure time τ is chosen as environmental change, which normally should be about 12 hours/day, is varied (0-12 hours/day). Each day sample from different exposure time is taken, its color is recorded using HP Deskjet 1050 scanner with 1200 dpi, and its chlorophyll content is obtained from absorption spectrum measured using Campspec M501 Single Beam UV/Vis Spectrophotometer after it is rinsed in 85 % acetone solution and the information from the spectrum is calculated using Arnon method. It has been observed that average wavelength of leaf color λavg is decreased from 570.55 nm to 566.01 nm as is measured for t = 1 - 10 days with τ = 9 hours/day, but chlorophyll concentration C is increased from 0.015 g/l to 3.250 g/l and from 0.000 g/l to 0.774 g/l for chlorophyll a and b, respectively. Other value of τ gives similar results. Based on these results an empirical relation between concentration of chlorophyll a Cc-
Hypertensive emergency masquerading as phaeochromocytoma: a report of two cases.
Hulkower, Raphael; Gubbi, Sriram; Meholli, Mimoza; Schubart, Ulrich
2017-08-07
We report two cases of patients who were hospitalised for hypertensive emergency. In both cases, laboratory testing during admission revealed elevated normetanephrines in the range of 4-5 times the upper limit of normal using liquid chromatography with mass spectrometry. Imaging studies did not localise any phaeochromocytoma or paraganglioma (PPGL). Repeat biochemical testing after discharge was within normal limits in both cases. These observations suggest that hypertensive emergency should be recognised as a potential cause of 'false-positive' laboratory findings in the diagnostic assessment for PPGL. © BMJ Publishing Group Ltd (unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Introduction of a rapid, simple radioimmunoassay and quality control scheme for thyroxine.
Nye, L; Hassan, M; Willmott, E; Landon, J
1976-01-01
A simple radioimmunoassay has been developed for service purposes to determine serum total thyroxine levels. Only three additions are required, of standard or sample, labelled thyroxine and antibody in polyethylene glycol. After 2 hours' incubation at room temperature the antibody-bound and free fractions are separated by centrifugation. Serum total thyroxine levels were measured in 195 euthyroid subjects and it was established that normal values lay within the range 57 to 155 nmol/1. Serial blood samples taken over a 24-hour period, from 11 subjects, indicated that there was no circadian rhythm so that samples for total thyroxine assay can be taken at any time of the day. Similar results were obtained using serum or plasma. Satisfactory results were obtained for three quality control sera when measured by seven different laboratories using this method. PMID:932232
Apparent elevated creatinine after ingestion of nitromethane: interference with the Jaffe reaction.
Killorn, Erin; Lim, Rodrick K; Rieder, Michael
2011-02-01
We assessed a 2-year 4-month-old boy found to have a persistently elevated serum creatinine (peak 926 μmol/L) as measured by the Jaffe reaction after ingesting an unknown quantity of fuel for a model car, which commonly contains nitromethane. The patient was otherwise clinically well and the remaining investigations were unremarkable. When creatinine concentrations were measured with specific enzymatic testing on these same blood samples, all values were within normal limits. Nitromethane has been shown to interfere with the determination of serum creatinine through the Jaffe reaction. Because many ingestions present only rarely, it is not possible for the emergency department clinician to be aware of all toxin factors affecting patient management. This case illustrates the importance of analysis of laboratory results in the context of the patient's clinical status.
Reference values of thirty-one frequently used laboratory markers for 75-year-old males and females
Ryden, Ingvar; Lind, Lars
2012-01-01
Background We have previously reported reference values for common clinical chemistry tests in healthy 70-year-old males and females. We have now repeated this study 5 years later to establish reference values also at the age of 75. It is important to have adequate reference values for elderly patients as biological markers may change over time, and adequate reference values are essential for correct clinical decisions. Methods We have investigated 31 frequently used laboratory markers in 75-year-old males (n = 354) and females (n = 373) without diabetes. The 2.5 and 97.5 percentiles for these markers were calculated according to the recommendations of the International Federation of Clinical Chemistry. Results Reference values are reported for 75-year-old males and females for 31 frequently used laboratory markers. Conclusion There were minor differences between reference intervals calculated with and without individuals with cardiovascular diseases. Several of the reference intervals differed from Scandinavian reference intervals based on younger individuals (Nordic Reference Interval Project). PMID:22300333
Marzok, Mohamed A; Badawy, Adel M; El-Khodery, Sabry A
2017-05-01
To determine the normal values and repeatability for Schirmer tear test (STT) in clinically normal dromedary camels and to analyze the influence of the age and gender on these values. Thirty clinically normal dromedary camels of different ages (calves, immature, and mature). Schirmer tear tests I and II were performed using commercial STT strips. Three measurements were obtained from each eye over three consecutive weeks, and the variance of these measurements was determined. Mean values and coefficient of variation of STT I and STT II for the right and left eyes varied significantly among camel groups (P < 0.05). For STT I, the most frequently recorded values were >14-18, > 22-26, and >30-34 mm/min in calves, immature camels, and mature camels, respectively. For STT II, however, the most frequently recorded values were 7-14, >10-18, and >26-30 mm/min, respectively. The interassay coefficients of variation were 1.7-14.4% and were significantly lower in mature camels than in calves and immature camels (P < 0.05). Age was positively correlated with STT I (r = 0.81) and STT II values (r = 0.88). No significant variations were found between genders. This preliminary study reports STT I and II values and repeatability in normal dromedary camels. This information may assist veterinary practitioners in complete ophthalmic examinations and in accurate diagnosis of ocular surface diseases affecting the tear film in this species. © 2016 American College of Veterinary Ophthalmologists.
Horizontal and vertical integration in hospital laboratories and the laboratory information system.
Friedman, B A; Mitchell, W
1990-09-01
An understanding of horizontal and vertical integration and their quasi-integration variants is important for pathologists to formulate a competitive strategy for hospital clinical laboratories. These basic organizational concepts, in turn, are based on the need to establish control over critical laboratory inputs and outputs. The pathologist seeks greater control of mission-critical system inputs and outputs to increase the quality and efficiency of the laboratory operations. The LIS produces horizontal integration of the various hospital laboratories by integrating them vertically. Forward vertical quasi-integration of the laboratories is mediated primarily by the LIS through front-end valued-added features such as reporting of results and creating a long-term on-line test result archive. These features increase the value of the information product of pathology for clinicians and increase the cost of switching to another system. The LIS can also serve as a means for customizing the information product of the laboratories to appeal to new market segments such as hospital administrators.
Boston City Hospital and the Thorndike Memorial Laboratory: the birth of modern haematology.
Elrod, Jeffrey M; Karnad, Anand B
2003-05-01
Established in 1923, the Thorndike Memorial Laboratory at Boston City Hospital was the first clinical research laboratory in a municipal hospital in the United States of America. Minot and Castle, who were the second and third directors of the Laboratory, were pioneer haematologists and clinical investigators of the highest calibre who created an atmosphere at the Laboratory that would foster patient-centred research and attract the best physician-scientists to work and train there. The haematology research division of the Laboratory made important original contributions to the understanding of the pathophysiology of anaemia, the mechanisms of red cell and platelet destruction and the phagocytic role of the spleen, the nature of haemoglobin (normal and sickle cell), the nature of haemophilia and its therapy and the early classification of lymphoma. It contributed to the Thorndike Memorial Laboratory's worldwide reputation as a model research laboratory and established its reputation as the birthplace of modern haematology.
[Safety in the Microbiology laboratory].
Rojo-Molinero, Estrella; Alados, Juan Carlos; de la Pedrosa, Elia Gómez G; Leiva, José; Pérez, José L
2015-01-01
The normal activity in the laboratory of microbiology poses different risks - mainly biological - that can affect the health of their workers, visitors and the community. Routine health examinations (surveillance and prevention), individual awareness of self-protection, hazard identification and risk assessment of laboratory procedures, the adoption of appropriate containment measures, and the use of conscientious microbiological techniques allow laboratory to be a safe place, as records of laboratory-acquired infections and accidents show. Training and information are the cornerstones for designing a comprehensive safety plan for the laboratory. In this article, the basic concepts and the theoretical background on laboratory safety are reviewed, including the main legal regulations. Moreover, practical guidelines are presented for each laboratory to design its own safety plan according its own particular characteristics. Copyright © 2014 Elsevier España, S.L.U. y Sociedad Española de Enfermedades Infecciosas y Microbiología Clínica. All rights reserved.
Generation and composition of medical wastes from private medical microbiology laboratories.
Komilis, Dimitrios; Makroleivaditis, Nikolaos; Nikolakopoulou, Eftychia
2017-03-01
A study on the generation rate and the composition of solid medical wastes (MW) produced by private medical microbiology laboratories (PMML) was conducted in Greece. The novelty of the work is that no such information exists in the literature for this type of laboratories worldwide. Seven laboratories were selected with capacities that ranged from 8 to 88 examinees per day. The study lasted 6months and daily recording of MW weights was done over 30days during that period. The rates were correlated to the number of examinees, examinations and personnel. Results indicated that on average 35% of the total MW was hazardous (infectious) medical wastes (IFMW). The IFMW generation rates ranged from 11.5 to 32.5g examinee -1 d -1 while an average value from all 7 labs was 19.6±9.6g examinee -1 d -1 or 2.27±1.11g examination -1 d -1 . The average urban type medical waste generation rate was 44.2±32.5g examinee -1 d -1 . Using basic regression modeling, it was shown that the number of examinees and examinations can be predictors of the IFMW generation, but not of the urban type MW generation. The number of examinations was a better predictor of the MW amounts than the number of examinees. Statistical comparison of the means of the 7PMML was done with standard ANOVA techniques after checking the normality of the data and after doing the appropriate transformations. Based on the results of this work, it is approximated that 580 tonnes of infectious MW are generated annually by the PMML in Greece. Copyright © 2017 Elsevier Ltd. All rights reserved.
Rayidi, Manasa
2015-01-01
Introduction The global prevalence of chronic kidney disease (CKD) is estimated to be 8-16%. Studies have shown that the increased mortality in patients with CKD is due to anemia that leads to cardiovascular disease (CVD), also known as “Cardio renal anemia syndrome”. The present study was undertaken to look into the laboratory profiles of end stage renal disease (ESRD) patients. Aim To study the laboratory profiles of End stage renal disease (ESRD) patients coming for hemodialysis. Materials and Methods The study was a retrospective, cross- sectional study done by collecting data from the medical case records of all patients during a period of one year from January 1st 2014 to December 31st 2014. Records of a total of 140 patients who underwent hemodialysis during this period were taken. The laboratory profiles that was recorded included haemoglobin, serum sodium, potassium, chloride, fasting glucose, calcium and phosphorus. Results The mean age of the subjects was 53.5±14.5 yrs. All the patients had moderate anaemia. There was a significant difference in the mean systolic and diastolic blood pressure, serum creatinine and serum urea values between males and females. The mean serum calcium levels were low. Conclusion The present study is the first such study in this rural area and shows evidence of a relatively young population with ESRD having moderate anaemia and hypertension. There is evidence of hypocalcaemia and serum phosphorus is on the higher end of the normal range. These findings are usually associated with a higher risk of mortality. With the explosion of diabetes and hypertension in India, chronic kidney disease should be diagnosed and managed as early as possible if not prevented. PMID:26557511