Determination of stress intensity factors for interface cracks under mixed-mode loading
NASA Technical Reports Server (NTRS)
Naik, Rajiv A.; Crews, John H., Jr.
1992-01-01
A simple technique was developed using conventional finite element analysis to determine stress intensity factors, K1 and K2, for interface cracks under mixed-mode loading. This technique involves the calculation of crack tip stresses using non-singular finite elements. These stresses are then combined and used in a linear regression procedure to calculate K1 and K2. The technique was demonstrated by calculating three different bimaterial combinations. For the normal loading case, the K's were within 2.6 percent of an exact solution. The normalized K's under shear loading were shown to be related to the normalized K's under normal loading. Based on these relations, a simple equation was derived for calculating K1 and K2 for mixed-mode loading from knowledge of the K's under normal loading. The equation was verified by computing the K's for a mixed-mode case with equal and normal shear loading. The correlation between exact and finite element solutions is within 3.7 percent. This study provides a simple procedure to compute K2/K1 ratio which has been used to characterize the stress state at the crack tip for various combinations of materials and loadings. Tests conducted over a range of K2/K1 ratios could be used to fully characterize interface fracture toughness.
NASA Technical Reports Server (NTRS)
Whalley, Matthew S.
1993-01-01
A piloted simulation study was performed by the U.S. Army Aeroflighydynamics Directorate to develop insight into the maneuverability requirements for aggressive helicopter maneuvering tasks such as air-to-air combat. Both a conventional helicopter and a helicopter with auxiliary thrust were examined. The aircraft parameters of interest were the normal and longitudinal load factor envelopes. Of particular interest were the mission performance and handling qualities tradeoffs with the parameters of interest. Two air-to-air acquisition and tracking tasks and a return-to-cover task were performed to assess mission performance. Results indicate that without auxiliary thrust, the ownship normal load factor capability needs to match that of the adversary in order to provide satisfactory handling qualities. Auxiliary thrust provides significant handling qualities advantages and can be substituted to some extent for normal load factor capability. Auxiliary thrust levels as low as 0.2 thrust/weight can provide significant handling qualities advantages.
Code of Federal Regulations, 2010 CFR
2010-01-01
... STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Structure Flight Loads § 23.321 General. (a) Flight load factors represent the ratio of the aerodynamic force component (acting normal to... distribution of disposable load within the operating limitations specified in §§ 23.1583 through 23.1589. (c...
14 CFR 27.337 - Limit maneuvering load factor.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Limit maneuvering load factor. 27.337 Section 27.337 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: NORMAL CATEGORY ROTORCRAFT Strength Requirements Flight Loads § 27.337...
40 CFR Table 33 to Subpart G of... - Saturation Factors
Code of Federal Regulations, 2011 CFR
2011-07-01
... service 0.60 Submerged loading: dedicated vapor balance service 1.00 Splash loading of a clean cargo tank 1.45 Splash loading: dedicated normal service 1.45 Splash loading: dedicated vapor balance service 1...
40 CFR Table 33 to Subpart G of... - Saturation Factors
Code of Federal Regulations, 2014 CFR
2014-07-01
... service 0.60 Submerged loading: dedicated vapor balance service 1.00 Splash loading of a clean cargo tank 1.45 Splash loading: dedicated normal service 1.45 Splash loading: dedicated vapor balance service 1...
40 CFR Table 33 to Subpart G of... - Saturation Factors
Code of Federal Regulations, 2012 CFR
2012-07-01
... service 0.60 Submerged loading: dedicated vapor balance service 1.00 Splash loading of a clean cargo tank 1.45 Splash loading: dedicated normal service 1.45 Splash loading: dedicated vapor balance service 1...
40 CFR Table 33 to Subpart G of... - Saturation Factors
Code of Federal Regulations, 2010 CFR
2010-07-01
... service 0.60 Submerged loading: dedicated vapor balance service 1.00 Splash loading of a clean cargo tank 1.45 Splash loading: dedicated normal service 1.45 Splash loading: dedicated vapor balance service 1...
40 CFR Table 33 to Subpart G of... - Saturation Factors
Code of Federal Regulations, 2013 CFR
2013-07-01
... service 0.60 Submerged loading: dedicated vapor balance service 1.00 Splash loading of a clean cargo tank 1.45 Splash loading: dedicated normal service 1.45 Splash loading: dedicated vapor balance service 1...
Code of Federal Regulations, 2010 CFR
2010-01-01
... STANDARDS: NORMAL CATEGORY ROTORCRAFT Strength Requirements Flight Loads § 27.321 General. (a) The flight load factor must be assumed to act normal to the longitudinal axis of the rotorcraft, and to be equal... from the design minimum weight to the design maximum weight; and (2) With any practical distribution of...
14 CFR 23.787 - Baggage and cargo compartments.
Code of Federal Regulations, 2010 CFR
2010-01-01
... AIRCRAFT AIRWORTHINESS STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Design and... critical load distributions at the appropriate maximum load factors corresponding to the flight and ground...
Numerical investigation of contact stresses for fretting fatigue damage initiation
NASA Astrophysics Data System (ADS)
Bhatti, N. A.; Abdel Wahab, M.
2017-05-01
Fretting fatigue phenomena occurs due to interaction between contacting bodies under application of cyclic and normal loads. In addition to environmental conditions and material properties, the response at the contact interface highly depends on the combination of applied loads. High stress concentration is present at the contact interface, which can start the damage nucleation process. At the culmination of nucleation process several micro cracks are initiated, ultimately leading to the structural failure. In this study, effect of ratio of tangential to normal load on contact stresses, slip amplitude and damage initiation is studied using finite element analysis. The results are evaluated for Ruiz parameter as it involves the slip amplitude which in an important factor in fretting fatigue conditions. It is observed that tangential to normal load ratio influences the stick zone size and damage initiation life. Furthermore, it is observed that tensile stress is the most important factor that drives the damage initiation to failure for the cases where failure occurs predominantly in mode I manner.
14 CFR 23.785 - Seats, berths, litters, safety belts, and shoulder harnesses.
Code of Federal Regulations, 2014 CFR
2014-01-01
... combination of structural analysis and static load tests to limit load; or (3) Static load tests to ultimate... OF TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY... resulting from the ultimate static load factors prescribed in § 23.561(b)(2) of this part. Each occupant...
14 CFR 23.785 - Seats, berths, litters, safety belts, and shoulder harnesses.
Code of Federal Regulations, 2011 CFR
2011-01-01
... combination of structural analysis and static load tests to limit load; or (3) Static load tests to ultimate... OF TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY... resulting from the ultimate static load factors prescribed in § 23.561(b)(2) of this part. Each occupant...
14 CFR 23.785 - Seats, berths, litters, safety belts, and shoulder harnesses.
Code of Federal Regulations, 2010 CFR
2010-01-01
... combination of structural analysis and static load tests to limit load; or (3) Static load tests to ultimate... OF TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY... resulting from the ultimate static load factors prescribed in § 23.561(b)(2) of this part. Each occupant...
14 CFR 23.785 - Seats, berths, litters, safety belts, and shoulder harnesses.
Code of Federal Regulations, 2012 CFR
2012-01-01
... combination of structural analysis and static load tests to limit load; or (3) Static load tests to ultimate... OF TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY... resulting from the ultimate static load factors prescribed in § 23.561(b)(2) of this part. Each occupant...
14 CFR 23.785 - Seats, berths, litters, safety belts, and shoulder harnesses.
Code of Federal Regulations, 2013 CFR
2013-01-01
... combination of structural analysis and static load tests to limit load; or (3) Static load tests to ultimate... OF TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY... resulting from the ultimate static load factors prescribed in § 23.561(b)(2) of this part. Each occupant...
Kovochich, Michael; Fung, Ernest S; Donovan, Ellen; Unice, Kenneth M; Paustenbach, Dennis J; Finley, Brent L
2018-04-01
Advantages of second-generation metal-on-metal (MoM) hip implants include low volumetric wear rates and the release of nanosized wear particles that are chemically inert and readily cleared from local tissue. In some patients, edge loading conditions occur, which result in higher volumetric wear. The objective of this study was to characterize the size, morphology, and chemistry of wear particles released from MoM hip implants during normal (40° angle) and edge-loading (65° angle with microseparation) conditions. The mean primary particle size by volume under normal wear was 35 nm (range: 9-152 nm) compared with 95 nm (range: 6-573 nm) under edge-loading conditions. Hydrodynamic diameter analysis by volume showed that particles from normal wear were in the nano- (<100 nm) to submicron (<1000 nm) size range, whereas edge-loading conditions generated particles that ranged from <100 nm up to 3000-6000 nm in size. Particles isolated from normal wear were primarily chromium (98.5%) and round to oval in shape. Edge-loading conditions generated more elongated particles (4.5%) (aspect ratio ≥ 2.5) and more CoCr alloy particles (9.3%) compared with normal wear conditions (1.3% CoCr particles). By total mass, edge-loading particles contained approximately 640-fold more cobalt than normal wear particles. Our findings suggest that high wear conditions are a potential risk factor for adverse local tissue effects in MoM patients who experience edge loading. This study is the first to characterize both the physical and chemical characteristics of MoM wear particles collected under normal and edge-loading conditions. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 986-996, 2018. © 2017 Wiley Periodicals, Inc.
NASA Technical Reports Server (NTRS)
Kostenuik, P. J.; Harris, J.; Halloran, B. P.; Turner, R. T.; Morey-Holton, E. R.; Bikle, D. D.
1999-01-01
Skeletal unloading decreases bone formation and osteoblast number in vivo and decreases the number and proliferation of bone marrow osteoprogenitor (BMOp) cells in vitro. We tested the ability of parathyroid hormone (PTH) to stimulate BMOp cells in vivo by treating Sprague Dawley rats (n = 32) with intermittent PTH(1-34) (1 h/day at 8 microg/100 g of body weight), or with vehicle via osmotic minipumps during 7 days of normal weight bearing or hind limb unloading. Marrow cells were flushed from the femur and cultured at the same initial density for up to 21 days. PTH treatment of normally loaded rats caused a 2.5-fold increase in the number of BMOp cells, with similar increases in alkaline phosphatase (ALP) activity and mineralization, compared with cultures from vehicle-treated rats. PTH treatment of hind limb unloaded rats failed to stimulate BMOp cell number, ALP activity, or mineralization. Hind limb unloading had no significant effect on PTH receptor mRNA or protein levels in the tibia. Direct in vitro PTH challenge of BMOp cells isolated from normally loaded bone failed to stimulate their proliferation and inhibited their differentiation, suggesting that the in vivo anabolic effect of intermittent PTH on BMOp cells was mediated indirectly by a PTH-induced factor. We hypothesize that this factor is insulin-like growth factor-I (IGF-I), which stimulated the in vitro proliferation and differentiation of BMOp cells isolated from normally loaded bone, but not from unloaded bone. These results suggest that IGF-I mediates the ability of PTH to stimulate BMOp cell proliferation in normally loaded bone, and that BMOp cells in unloaded bone are resistant to the anabolic effect of intermittent PTH therapy due to their resistance to IGF-I.
The effect of transverse shear in a cracked plate under skew-symmetric loading
NASA Technical Reports Server (NTRS)
Delale, F.; Erdogan, F.
1979-01-01
The problem of an elastic plate containing a through crack and subjected to twisting moments or transverse shear loads is considered. By using a bending theory which allows the satisfaction of the boundary conditions on the crack surface regarding the normal and the twisting moments and the transverse shear load separately, it is found that the resulting asymptotic stress field around the crack tip becomes identical to that given by the elasticity solutions of the plane strain and antiplane shear problems. The problem is solved for uniformly distributed or concentrated twisting moment or transverse shear load and the normalized Mode II and Mode III stress-intensity factors are tabulated. The results also include the effect of the Poisson's ratio and material orthotropy for specially orthotropic materials on the stress-intensity factors.
Probabilistic model of bridge vehicle loads in port area based on in-situ load testing
NASA Astrophysics Data System (ADS)
Deng, Ming; Wang, Lei; Zhang, Jianren; Wang, Rei; Yan, Yanhong
2017-11-01
Vehicle load is an important factor affecting the safety and usability of bridges. An statistical analysis is carried out in this paper to investigate the vehicle load data of Tianjin Haibin highway in Tianjin port of China, which are collected by the Weigh-in- Motion (WIM) system. Following this, the effect of the vehicle load on test bridge is calculated, and then compared with the calculation result according to HL-93(AASHTO LRFD). Results show that the overall vehicle load follows a distribution with a weighted sum of four normal distributions. The maximum vehicle load during the design reference period follows a type I extremum distribution. The vehicle load effect also follows a weighted sum of four normal distributions, and the standard value of the vehicle load is recommended as 1.8 times that of the calculated value according to HL-93.
Experimental Investigations on Axially and Eccentrically Loaded Masonry Walls
NASA Astrophysics Data System (ADS)
Keshava, Mangala; Raghunath, Seshagiri Rao
2017-12-01
In India, un-reinforced masonry walls are often used as main structural components in load bearing structures. Indian code on masonry accounts the reduction in strength of walls by using stress reduction factors in its design philosophy. This code was introduced in 1987 and reaffirmed in 1995. The present study investigates the use of these factors for south Indian masonry. Also, with the gaining popularity in block work construction, the aim of this study was to find out the suitability of these factors given in the Indian code to block work masonry. Normally, the load carrying capacity of masonry walls can be assessed in three ways, namely, (1) tests on masonry constituents, (2) tests on masonry prisms and (3) tests on full-scale wall specimens. Tests on bricks/blocks, cement-sand mortar, brick/block masonry prisms and 14 full-scale brick/block masonry walls formed the experimental investigation. The behavior of the walls was investigated under varying slenderness and eccentricity ratios. Hollow concrete blocks normally used as in-fill masonry can be considered as load bearing elements as its load carrying capacity was found to be high when compared to conventional brick masonry. Higher slenderness and eccentricity ratios drastically reduced the strength capacity of south Indian brick masonry walls. The reduction in strength due to slenderness and eccentricity is presented in the form of stress reduction factors in the Indian code. These factors obtained through experiments on eccentrically loaded brick masonry walls was lower while that of brick/block masonry under axial loads was higher than the values indicated in the Indian code. Also the reduction in strength is different for brick and block work masonry thus indicating the need for separate stress reduction factors for these two masonry materials.
The effect of normal load on polytetrafluoroethylene tribology.
Barry, Peter R; Chiu, Patrick Y; Perry, Scott S; Sawyer, W Gregory; Phillpot, Simon R; Sinnott, Susan B
2009-04-08
The tribological behavior of oriented poly(tetrafluoroethylene) (PTFE) sliding surfaces is examined as a function of sliding direction and applied normal load in classical molecular dynamics (MD) simulations. The forces are calculated with the second-generation reactive empirical bond-order potential for short-range interactions, and with a Lennard-Jones potential for long-range interactions. The range of applied normal loads considered is 5-30 nN. The displacement of interfacial atoms from their initial positions during sliding is found to vary by a factor of seven, depending on the relative orientation of the sliding chains. However, within each sliding configuration the magnitude of the interfacial atomic displacements exhibits little dependence on load over the range considered. The predicted friction coefficients are also found to vary with chain orientation and are in excellent quantitative agreement with experimental measurements.
The effect of normal load on polytetrafluoroethylene tribology
NASA Astrophysics Data System (ADS)
Barry, Peter R.; Chiu, Patrick Y.; Perry, Scott S.; Sawyer, W. Gregory; Phillpot, Simon R.; Sinnott, Susan B.
2009-04-01
The tribological behavior of oriented poly(tetrafluoroethylene) (PTFE) sliding surfaces is examined as a function of sliding direction and applied normal load in classical molecular dynamics (MD) simulations. The forces are calculated with the second-generation reactive empirical bond-order potential for short-range interactions, and with a Lennard-Jones potential for long-range interactions. The range of applied normal loads considered is 5-30 nN. The displacement of interfacial atoms from their initial positions during sliding is found to vary by a factor of seven, depending on the relative orientation of the sliding chains. However, within each sliding configuration the magnitude of the interfacial atomic displacements exhibits little dependence on load over the range considered. The predicted friction coefficients are also found to vary with chain orientation and are in excellent quantitative agreement with experimental measurements.
Normalization Of Thermal-Radiation Form-Factor Matrix
NASA Technical Reports Server (NTRS)
Tsuyuki, Glenn T.
1994-01-01
Report describes algorithm that adjusts form-factor matrix in TRASYS computer program, which calculates intraspacecraft radiative interchange among various surfaces and environmental heat loading from sources such as sun.
NASA Technical Reports Server (NTRS)
Hartranft, R. J.; Sih, G. C.
1973-01-01
The closed form expressions for the stress intensity factors due to concentrated forces applied to the surfaces of a half plane crack in an infinite body are used to generate solutions for distributed loads in this geometry. The stress intensity factors for uniformly distributed loads applied over a rectangular portion of the crack surface are given in closed form. An example of non-uniformly distributed loads which can be treated numerically is also included. In particular, combinations of normal and shear stresses on the crack which simulate the case of loading at an angle to the crack front are considered. The resulting stress intensity factors are combined with the strain energy density fracture criterion for the purpose of predicting the most likely direction of crack propagation. The critical value of the energy density factor can then be used for determining the allowable load on a specimen with a crack front not perpendicular to the tensile axis.
Optimizing fish sampling for fish - mercury bioaccumulation factors
Scudder Eikenberry, Barbara C.; Riva-Murray, Karen; Knightes, Christopher D.; Journey, Celeste A.; Chasar, Lia C.; Brigham, Mark E.; Bradley, Paul M.
2015-01-01
Fish Bioaccumulation Factors (BAFs; ratios of mercury (Hg) in fish (Hgfish) and water (Hgwater)) are used to develop Total Maximum Daily Load and water quality criteria for Hg-impaired waters. Both applications require representative Hgfish estimates and, thus, are sensitive to sampling and data-treatment methods. Data collected by fixed protocol from 11 streams in 5 states distributed across the US were used to assess the effects of Hgfish normalization/standardization methods and fish sample numbers on BAF estimates. Fish length, followed by weight, was most correlated to adult top-predator Hgfish. Site-specific BAFs based on length-normalized and standardized Hgfish estimates demonstrated up to 50% less variability than those based on non-normalized Hgfish. Permutation analysis indicated that length-normalized and standardized Hgfish estimates based on at least 8 trout or 5 bass resulted in mean Hgfish coefficients of variation less than 20%. These results are intended to support regulatory mercury monitoring and load-reduction program improvements.
Manorama, Abinand; Meyer, Ronald; Wiseman, Robert; Bush, Tamara Reid
2013-06-01
Forces applied to the skin cause a decrease in regional blood flow. This decrease in blood flow can cause tissue necrosis and lead to the formation of deep, penetrating wounds called pressure ulcers. These wounds are detrimental to individuals with compromised health, such as the elderly and spinal-cord injured. Although surface pressure is known to be a primary risk factor for developing a pressure ulcer, a seated individual rarely experiences pressure alone but rather combined loading which includes pressure as well as shear force on the skin. However, little research has been conducted to quantify the effects of shear forces on blood flow. Fifteen men were tested in a magnetic resonance imaging scanner under no load, a normal load, and a combination of normal and shear loads. Changes in arterial and venous blood flow in the forearm were measured using magnetic resonance angiography phase-contrast imaging. The blood flow in the anterior interosseous artery and basilic vein of the forearm decreased with the application of normal loads, and decreased further with the addition of shear loads. Marginal to significant differences at a 90% confidence level (P=0.08, 0.10) were observed, and medium to high effect sizes (0.3 to 0.5) were obtained. Based on these results, shear force is an important factor to consider in relation to pressure ulcer propagation and prevention, and hence, future prevention approaches should also focus on mitigating shear loads. Copyright © 2013 Elsevier Ltd. All rights reserved.
Renal Response to Acid Load after Phenformin
Rooth, Gösta; Bandman, Ulf
1973-01-01
Normally the kidneys respond to an acid load by increased ammonia production. In six patients with adult-type diabetes this response was reduced by a mean 50% after a therapeutic dose of phenformin. The reduced ability to compensate for acid loads may be one factor leading to metabolic acidosis and lactoacidosis sometimes associated with phenformin therapy. PMID:4753235
[Characteristics of fugitive dust emission from paved road near construction activities].
Tian, Gang; Fan, Shou-Bin; Li, Gang; Qin, Jian-Ping
2007-11-01
Because of the mud/dirt carryout from construction activities, the silt loading of paved road nearby is higher and the fugitive dust emission is stronger. By sampling and laboratory analysis of the road surface dust samples, we obtain the silt loading (mass of material equal to or less than 75 micromaters in physical diameter per unit area of travel surface) of paved roads near construction activities. The result show that silt loading of road near construction activities is higher than "normal road", and silt loading is negatively correlated with length from construction's door. According to AP-42 emission factor model of fugitive dust from roads, the emission factor of influenced road is 2 - 10 times bigger than "normal road", and the amount of fugitive dust emission influenced by one construction activity is "equivalent" to an additional road length of approximately 422 - 3 800 m with the baseline silt loading. Based on the spatial and temporal distribution of construction activities, in 2002 the amount of PM10 emission influenced by construction activities in Beijing city areas account of for 59% of fugitive dust from roads.
Vibration of high-voltage electric machines with rotors on rolling bearings
NASA Astrophysics Data System (ADS)
Shekyan, H. G.; Gevorgyan, A. V.
2018-04-01
The paper presents an investigation of vibrational activity of electric machines due to high-harmonic vibrational loadings. It is shown that the vibrational loadings experienced by bearings may result in the interruption of their normal operation and even take them out of action. Therefore, the values of the vibrational speed-up leading to high harmonics are factors determining the admissible dynamic loading on the bearings. In the paper, an attempt is made to consider the factors which result in origination of high harmonics and to illustrate methods for their smoothing.
Influence of immediate loading on provisional restoration in dental implant stability
NASA Astrophysics Data System (ADS)
Ikbal, M.; Odang, R. W.; Indrasari, M.; Dewi, R. S.
2017-08-01
The success of dental implant treatment is determined by the primary stability at placement. One factor that could influence this stability is occlusal loading through provisional restoration. Two types of loading protocols are usually used: immediate and delayed loading. However, some controversies remain about the influence of occlusal loading on implant stability. Therefore, the influence of immediate loading on implant stability must be studied. An animal study was conducted by placing nine dental implants in the mandibular jaw of three Macaca fascicularis. Provisional restorations with various occlusal contacts (no, light, and normal contact) were placed on the implant. The implant stability was measured using the Ostell ISQ three times: immediately (baseline) and at the first and second months after implant placement. The implant stability between implants with no and normal occlusal contact as well as light and normal occlusal contact showed significant differences (p < 0.05) at the first and second months after implant placement. However, no significant increase (p > 0.05) in implant stability was seen at the baseline and the first and second months after implant placement for all occlusal contact groups. Immediate loading influenced the implant stability, and provisional restoration of implant without occlusal contact showed the highest implant stability.
Articular cartilage and subchondral bone in the pathogenesis of osteoarthritis.
Goldring, Mary B; Goldring, Steven R
2010-03-01
The articular surface plays an essential role in load transfer across the joint, and conditions that produce increased load transfer or altered patterns of load distribution accelerate the development of osteoarthritis (OA). Current knowledge segregates the risk factors into two fundamental mechanisms related to the adverse effects of "abnormal" loading on normal cartilage or "normal" loading on abnormal cartilage. Although chondrocytes can modulate their functional state in response to loading, their capacity to repair and modify the surrounding extracellular matrix is limited in comparison to skeletal cells in bone. This differential adaptive capacity underlies the more rapid appearance of detectable skeletal changes, especially after acute injuries that alter joint mechanics. The imbalance in the adaptation of the cartilage and bone disrupts the physiological relationship between these tissues and further contributes to OA pathology. This review focuses on the specific articular cartilage and skeletal features of OA and the putative mechanisms involved in their pathogenesis.
Mullaney, John R.
2016-03-10
Loads of dissolved silica (DSi; flow-normalized and non-flow-normalized) increased slightly at most stations during the study period and were positively correlated to urbanized land in the basin and negatively correlated to area of open water. Concentrations and loads of chloride increased at 12 of the 14 sites during both periods. Increases likely are the result of an increase in the use of salt for deicing, as well as other factors related to urbanization and population growth, such as increases in wastewater discharge and discharge from septic systems.
Normalized stiffness ratios for mechanical characterization of isotropic acoustic foams.
Sahraoui, Sohbi; Brouard, Bruno; Benyahia, Lazhar; Parmentier, Damien; Geslain, Alan
2013-12-01
This paper presents a method for the mechanical characterization of isotropic foams at low frequency. The objective of this study is to determine the Young's modulus, the Poisson's ratio, and the loss factor of commercially available foam plates. The method is applied on porous samples having square and circular sections. The main idea of this work is to perform quasi-static compression tests of a single foam sample followed by two juxtaposed samples having the same dimensions. The load and displacement measurements lead to a direct extraction of the elastic constants by means of normalized stiffness and normalized stiffness ratio which depend on Poisson's ratio and shape factor. The normalized stiffness is calculated by the finite element method for different Poisson ratios. The no-slip boundary conditions imposed by the loading rigid plates create interfaces with a complex strain distribution. Beforehand, compression tests were performed by means of a standard tensile machine in order to determine the appropriate pre-compression rate for quasi-static tests.
Interim Report on Fatigue Characteristics of a Typical Metal Wing
NASA Technical Reports Server (NTRS)
Kepert, J L; Payne, A O
1956-01-01
Constant amplitude fatigue tests of seventy-two P-51D "Mustang" wings are reported. The tests were performed by a vibrational loading system and by an hydraulic loading device for conditions with and without varying amounts of pre-load. The results indicate that: (a) the frequency of occurrence of fatigue at any one location is related to the range of the loads applied, (b) the rate of propagation of visible cracks is more or less constant for a large portion of the life of the specimen, (c) the fatigue strength of the structure is similar to that of notched material having a theoretical stress concentration factor of more than 3.0, (d) the frequency distribution of fatigue life is approximately logarithmic normal, (e) the relative increase in fatigue life for a given pre-load depends on the maximum load of the loading cycle only, while the optimum pre-load value is approximately 85 percent of the ultimate failing load, and (f) that normal design procedure will not permit the determination of local stress levels with sufficient accuracy to determine the fatigue strength of an element of a redundant structure.
Wu, Tsu-Fang; Yao, Ya-Li; Lai, I-Lu; Lai, Chien-Chen; Lin, Pei-Lun; Yang, Wen-Ming
2015-01-01
PAX3 is a transcription factor critical to gene regulation in mammalian development. Mutations in PAX3 are associated with Waardenburg syndrome (WS), but the mechanism of how mutant PAX3 proteins cause WS remains unclear. Here, we found that PAX3 loads on mitotic chromosomes using its homeodomain. PAX3 WS mutants with mutations in homeodomain lose the ability to bind mitotic chromosomes. Moreover, loading of PAX3 on mitotic chromosomes requires arginine methylation, which is regulated by methyltransferase PRMT5 and demethylase JMJD6. Mutant PAX3 proteins that lose mitotic chromosome localization block cell proliferation and normal development of zebrafish. These results reveal the molecular mechanism of PAX3s loading on mitotic chromosomes and the importance of this localization pattern in normal development. Our findings suggest that PAX3 WS mutants interfere with the normal functions of PAX3 in a dominant negative manner, which is important to the understanding of the pathogenesis of Waardenburg syndrome. PMID:26149688
1980-07-01
Arnold. Some further insight into the problem is obtained here, however, when it is demonstrated that highly optimized structural designs may...aircraft of this type are normally designed to withstand loads up to 1.5 times the maximum limit load (load factor 8.0 to 8.67), the structure should...on the wing, for example, give rise to concentrated drag and chordwise loadings as does the recoil from firing wing mounted gun systems . The drag on
Lord, Megan S; Ellis, April L; Farrugia, Brooke L; Whitelock, John M; Grenett, Hernan; Li, Chuanyu; O'Grady, Robert L; DeCarlo, Arthur A
2017-03-28
The repair of dermal wounds, particularly in the diabetic population, poses a significant healthcare burden. The impaired wound healing of diabetic wounds is attributed to low levels of endogenous growth factors, including vascular endothelial growth factor (VEGF), that normally stimulate multiple phases of wound healing. In this study, chitosan scaffolds were prepared via freeze drying and loaded with plasmid DNA encoding perlecan domain I and VEGF189 and analyzed in vivo for their ability to promote dermal wound healing. The plasmid DNA encoding perlecan domain I and VEGF189 loaded scaffolds promoted dermal wound healing in normal and diabetic rats. This treatment resulted in an increase in the number of blood vessels and sub-epithelial connective tissue matrix components within the wound beds compared to wounds treated with chitosan scaffolds containing control DNA or wounded controls. These results suggest that chitosan scaffolds containing plasmid DNA encoding VEGF189 and perlecan domain I have the potential to induce angiogenesis and wound healing. Copyright © 2017 Elsevier B.V. All rights reserved.
Kinematic properties of the helicopter in coordinated turns
NASA Technical Reports Server (NTRS)
Chen, R. T. N.; Jeske, J. A.
1981-01-01
A study on the kinematic relationship of the variables of helicopter motion in steady, coordinated turns involving inherent sideslip is described. A set of exact kinematic equations which govern a steady coordinated helical turn about an Earth referenced vertical axis is developed. A precise definition for the load factor parameter that best characterizes a coordinated turn is proposed. Formulas are developed which relate the aircraft angular rates and pitch and roll attitudes to the turn parameters, angle of attack, and inherent sideslip. A steep, coordinated helical turn at extreme angles of attack with inherent sideslip is of primary interest. The bank angle of the aircraft can differ markedly from the tilt angle of the normal load factor. The normal load factor can also differ substantially from the accelerometer reading along the vertical body axis of the aircraft. Sideslip has a strong influence on the pitch attitude and roll rate of the helicopter. Pitch rate is independent of angle of attack in a coordinated turn and in the absence of sideslip, angular rates about the stability axes are independent of the aerodynamic characteristics of the aircraft.
Determinants of Standard Errors of MLEs in Confirmatory Factor Analysis
ERIC Educational Resources Information Center
Yuan, Ke-Hai; Cheng, Ying; Zhang, Wei
2010-01-01
This paper studies changes of standard errors (SE) of the normal-distribution-based maximum likelihood estimates (MLE) for confirmatory factor models as model parameters vary. Using logical analysis, simplified formulas and numerical verification, monotonic relationships between SEs and factor loadings as well as unique variances are found.…
Impact of measurement uncertainty from experimental load distribution factors on bridge load rating
NASA Astrophysics Data System (ADS)
Gangone, Michael V.; Whelan, Matthew J.
2018-03-01
Load rating and testing of highway bridges is important in determining the capacity of the structure. Experimental load rating utilizes strain transducers placed at critical locations of the superstructure to measure normal strains. These strains are then used in computing diagnostic performance measures (neutral axis of bending, load distribution factor) and ultimately a load rating. However, it has been shown that experimentally obtained strain measurements contain uncertainties associated with the accuracy and precision of the sensor and sensing system. These uncertainties propagate through to the diagnostic indicators that in turn transmit into the load rating calculation. This paper will analyze the effect that measurement uncertainties have on the experimental load rating results of a 3 span multi-girder/stringer steel and concrete bridge. The focus of this paper will be limited to the uncertainty associated with the experimental distribution factor estimate. For the testing discussed, strain readings were gathered at the midspan of each span of both exterior girders and the center girder. Test vehicles of known weight were positioned at specified locations on each span to generate maximum strain response for each of the five girders. The strain uncertainties were used in conjunction with a propagation formula developed by the authors to determine the standard uncertainty in the distribution factor estimates. This distribution factor uncertainty is then introduced into the load rating computation to determine the possible range of the load rating. The results show the importance of understanding measurement uncertainty in experimental load testing.
Simplified Design Method for Tension Fasteners
NASA Astrophysics Data System (ADS)
Olmstead, Jim; Barker, Paul; Vandersluis, Jonathan
2012-07-01
Tension fastened joints design has traditionally been an iterative tradeoff between separation and strength requirements. This paper presents equations for the maximum external load that a fastened joint can support and the optimal preload to achieve this load. The equations, based on linear joint theory, account for separation and strength safety factors and variations in joint geometry, materials, preload, load-plane factor and thermal loading. The strength-normalized versions of the equations are applicable to any fastener and can be plotted to create a "Fastener Design Space", FDS. Any combination of preload and tension that falls within the FDS represents a safe joint design. The equation for the FDS apex represents the optimal preload and load capacity of a set of joints. The method can be used for preliminary design or to evaluate multiple pre-existing joints.
Chow, Daniel H K; Kwok, Monica L Y; Cheng, Jack C Y; Lao, Miko L M; Holmes, Andrew D; Au-Yang, Alexander; Yao, Fiona Y D; Wong, M S
2006-10-01
Concerns have been raised regarding the effect of carrying a backpack on adolescent posture and balance, but the effect of backpack loading combined with other factors affecting balance, such as adolescent idiopathic scoliosis (AIS), has not been determined. This study examines the effects of backpack load on the posture and balance of schoolgirls with AIS and normal controls. The standing posture of 26 schoolgirls with mild AIS (mean age 13, Cobb angle 10-25 degrees ) and 20 age-matched normal schoolgirls were recorded without a backpack and while carrying a standard dual-strap backpack loaded at 7.5%, 10%, 12.5% and 15% of the subject's bodyweight (BW). Kinematics of the pelvis, trunk and head were recorded using a motion analysis system and centre of pressure (COP) data were recorded using a force platform. Reliable COP data could only be derived for 13 of the subjects with AIS. Increasing backpack load causes a significantly increased flexion of the trunk in relation to the pelvis and extension of the head in relation to the trunk, as well as increased antero-posterior range of COP motion. While backpack load appears to affect balance predominantly in the antero-posterior direction, differences between groups were more evident in the medio-lateral direction, with AIS subjects showing poor balance in this direction. Overall, carrying a backpack causes similar sagittal plane changes in posture and balance in both normal and AIS groups. Load size or subject group did not influence balance, but the additive effect of backpack carrying and AIS on postural control alters the risk of fall in this population. Therefore, load limit recommendations based on normal subjects should not be applicable to subjects with AIS.
Stuy on Fatigue Life of Aluminum Alloy Considering Fretting
NASA Astrophysics Data System (ADS)
Yang, Maosheng; Zhao, Hongqiang; Wang, Yunxiang; Chen, Xiaofei; Fan, Jiali
2018-01-01
To study the influence of fretting on Aluminum Alloy, a global finite element model considering fretting was performed using the commercial code ABAQUS. With which a new model for predicting fretting fatigue life has been presented based on friction work. The rationality and effectiveness of the model were validated according to the contrast of experiment life and predicting life. At last influence factor on fretting fatigue life of aerial aluminum alloy was investigated with the model. The results revealed that fretting fatigue life decreased monotonously with the increasing of normal load and then became constant at higher pressures. At low normal load, fretting fatigue life was found to increase with increase in the pad radius. At high normal load, however, the fretting fatigue life remained almost unchanged with changes in the fretting pad radius. The bulk stress amplitude had the dominant effect on fretting fatigue life. The fretting fatigue life diminished as the bulk stress amplitude increased.
Santos-Greatti, Mariana Morena de Vieira; da Silva, Márcia Guimarães; Ferreira, Carolina Sanitá Tafner; Marconi, Camila
2016-11-01
Studies have shown that not only bacterial vaginosis, but also intermediate vaginal flora has deleterious effects for women's reproductive health. However, literature still lacks information about microbiological and immunological aspects of intermediate flora. To characterize intermediate flora regarding levels of Interleukin (IL)-1beta, IL-6, IL-8, tumor necrosis factor-alpha, interleukin 1 receptor antagonist (IL-1ra), IL-10, sialidase; loads of Gardnerella vaginalis, total bacteria and to verify whether it is closer related to normal flora or bacterial vaginosis. This cross-sectional study enrolled 526 non-pregnant reproductive-aged women distributed in 3 groups according to pattern of vaginal flora using Nugent's system in normal, intermediate and bacterial vaginosis. Cervicovaginal levels of cytokines, sialidases, loads of G. vaginalis and total bacteria were assessed by ELISA, conversion of MUAN and quantitative real-time PCR, respectively. A principal component analysis(PCA) using all measured parameters was performed to compare the three different types of flora. Results showed that intermediate flora is associated with increased cervicovaginal IL-1beta in relation to normal flora(P<0.0001). When compared to bacterial vaginosis, intermediate flora has higher IL-8 and IL-10 levels(P<0.01). Sialidases were in significantly lower levels in normal and intermediate flora than bacterial vaginosis(P<0.0001). Loads of G. vaginalis and total bacterial differed among all groups(P<0.0001), being highest in bacterial vaginosis. PCA showed that normal and intermediate flora were closely scattered, while bacterial vaginosis were grouped separately. Although intermediate flora shows some differences in cytokines, sialidases and bacterial loads in relation to normal flora and bacterial vaginosis, when taken together, general microbiological and immunological pattern pattern of intermediate flora resembles the normal flora. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Zhou, Y.-B.; Li, X.-F.
2018-07-01
The electroelastic problem related to two collinear cracks of equal length and normal to the boundaries of a one-dimensional hexagonal piezoelectric quasicrystal layer is analysed. By using the finite Fourier transform, a mixed boundary value problem is solved when antiplane mechanical loading and inplane electric loading are applied. The problem is reduce to triple series equations, which are then transformed to a singular integral equation. For uniform remote loading, an exact solution is obtained in closed form, and explicit expressions for the electroelastic field are determined. The intensity factors of the electroelastic field and the energy release rate at the inner and outer crack tips are given and presented graphically.
Wu, Tsu-Fang; Yao, Ya-Li; Lai, I-Lu; Lai, Chien-Chen; Lin, Pei-Lun; Yang, Wen-Ming
2015-08-14
PAX3 is a transcription factor critical to gene regulation in mammalian development. Mutations in PAX3 are associated with Waardenburg syndrome (WS), but the mechanism of how mutant PAX3 proteins cause WS remains unclear. Here, we found that PAX3 loads on mitotic chromosomes using its homeodomain. PAX3 WS mutants with mutations in homeodomain lose the ability to bind mitotic chromosomes. Moreover, loading of PAX3 on mitotic chromosomes requires arginine methylation, which is regulated by methyltransferase PRMT5 and demethylase JMJD6. Mutant PAX3 proteins that lose mitotic chromosome localization block cell proliferation and normal development of zebrafish. These results reveal the molecular mechanism of PAX3s loading on mitotic chromosomes and the importance of this localization pattern in normal development. Our findings suggest that PAX3 WS mutants interfere with the normal functions of PAX3 in a dominant negative manner, which is important to the understanding of the pathogenesis of Waardenburg syndrome. © 2015 by The American Society for Biochemistry and Molecular Biology, Inc.
An analysis of life expectancy of airplane wings in normal cruising flight
NASA Technical Reports Server (NTRS)
Putnam, Abbott A
1945-01-01
In order to provide a basis for judging the relative importance of wing failure by fatigue and by single intense gusts, an analysis of wing life for normal cruising flight was made based on data on the frequency of atmospheric gusts. The independent variables considered in the analysis included stress-concentration factor, stress-load relation, wing loading, design and cruising speeds, design gust velocity, and airplane size. Several methods for estimating fatigue life from gust frequencies are discussed. The procedure selected for the analysis is believed to be simple and reasonably accurate, though slightly conservative.
Damage identification in highway bridges using distribution factors
NASA Astrophysics Data System (ADS)
Gangone, Michael V.; Whelan, Matthew J.
2017-04-01
The U.S. infrastructure system is well behind the needs of the 21st century and in dire need of improvements. The American Society of Civil Engineers (ASCE) graded America's Infrastructure as a "D+" in its recent 2013 Report Card. Bridges are a major component of the infrastructure system and were awarded a "C+". Nearly 25 percent of the nation's bridges are categorized as deficient by the Federal Highway Administration (FWHA). Most bridges were designed with an expected service life of roughly 50 years and today the average age of a bridge is 42 years. Finding alternative methods of condition assessment which captures the true performance of the bridge is of high importance. This paper discusses the monitoring of two multi-girder/stringer bridges at different ages of service life. Normal strain measurements were used to calculate the load distribution factor at the midspan of the bridge under controlled loading conditions. Controlled progressive damage was implemented to one of the superstructures to determine if the damage could be detected using the distribution factor. An uncertainty analysis, based on the accuracy and precision of the normal strain measurement, was undertaken to determine how effective it is to use the distribution factor measurement as a damage indicator. The analysis indicates that this load testing parameter may be an effective measure for detecting damage.
Code of Federal Regulations, 2010 CFR
2010-01-01
... load factor must be assumed to act normal to the longitudinal axis of the rotorcraft, and to be equal... from the design minimum weight to the design maximum weight; and (2) With any practical distribution of...
14 CFR 25.331 - Symmetric maneuvering conditions.
Code of Federal Regulations, 2011 CFR
2011-01-01
... Conditions § 25.331 Symmetric maneuvering conditions. (a) Procedure. For the analysis of the maneuvering... factor (at point A2 in § 25.333(b)), or the resulting tailplane normal load reaches its maximum...
Platelet-independent adhesion of calcium-loaded erythrocytes to von Willebrand factor
Bierings, Ruben; Meems, Henriet; Mul, Frederik P. J.; Geerts, Dirk; Vlaar, Alexander P. J.; Voorberg, Jan; Hordijk, Peter L.
2017-01-01
Adhesion of erythrocytes to endothelial cells lining the vascular wall can cause vaso-occlusive events that impair blood flow which in turn may result in ischemia and tissue damage. Adhesion of erythrocytes to vascular endothelial cells has been described in multiple hemolytic disorders, especially in sickle cell disease, but the adhesion of normal erythrocytes to endothelial cells has hardly been described. It was shown that calcium-loaded erythrocytes can adhere to endothelial cells. Because sickle erythrocyte adhesion to ECs can be enhanced by ultra-large von Willebrand factor multimers, we investigated whether calcium loading of erythrocytes could promote binding to endothelial cells via ultra-large von Willebrand factor multimers. We used (immunofluorescent) live-cell imaging of washed erythrocytes perfused over primary endothelial cells at venular flow rate. Using this approach, we show that calcium-loaded erythrocytes strongly adhere to histamine-stimulated primary human endothelial cells. This adhesion is mediated by ultra-large von Willebrand factor multimers. Von Willebrand factor knockdown or ADAMTS13 cleavage abolished the binding of erythrocytes to activated endothelial cells under flow. Platelet depletion did not interfere with erythrocyte binding to von Willebrand factor. Our results reveal platelet-independent adhesion of calcium-loaded erythrocytes to endothelium-derived von Willebrand factor. Erythrocyte adhesion to von Willebrand factor may be particularly relevant for venous thrombosis, which is characterized by the formation of erythrocyte-rich thrombi. PMID:28249049
Ovalization of Tubes Under Bending and Compression
NASA Technical Reports Server (NTRS)
Demer, L J; Kavanaugh, E S
1944-01-01
An empirical equation has been developed that gives the approximate amount of ovalization for tubes under bending loads. Tests were made on tubes in the d/t range from 6 to 14, the latter d/t ratio being in the normal landing gear range. Within the range of the series of tests conducted, the increase in ovalization due to a compression load in combination with a bending load was very small. The bending load, being the principal factor in producing the ovalization, is a rather complex function of the bending moment, d/t ratio, cantilever length, and distance between opposite bearing faces. (author)
Experimental studies of breaking of elastic tired wheel under variable normal load
NASA Astrophysics Data System (ADS)
Fedotov, A. I.; Zedgenizov, V. G.; Ovchinnikova, N. I.
2017-10-01
The paper analyzes the braking of a vehicle wheel subjected to disturbances of normal load variations. Experimental tests and methods for developing test modes as sinusoidal force disturbances of the normal wheel load were used. Measuring methods for digital and analogue signals were used as well. Stabilization of vehicle wheel braking subjected to disturbances of normal load variations is a topical issue. The paper suggests a method for analyzing wheel braking processes under disturbances of normal load variations. A method to control wheel baking processes subjected to disturbances of normal load variations was developed.
Lightweight concrete: development of mild steel in tension.
DOT National Transportation Integrated Search
2014-02-01
Concrete with a unit weight between that of traditional lightweight : concrete (LWC) and normal weight concrete (NWC) : is not covered in the American Association of State Highway : Transportation Officials (AASHTO) Load and Resistance Factor : Desig...
Statistical analysis of general aviation VG-VGH data
NASA Technical Reports Server (NTRS)
Clay, L. E.; Dickey, R. L.; Moran, M. S.; Payauys, K. W.; Severyn, T. P.
1974-01-01
To represent the loads spectra of general aviation aircraft operating in the Continental United States, VG and VGH data collected since 1963 in eight operational categories were processed and analyzed. Adequacy of data sample and current operational categories, and parameter distributions required for valid data extrapolation were studied along with envelopes of equal probability of exceeding the normal load factor (n sub z) versus airspeed for gust and maneuver loads and the probability of exceeding current design maneuver, gust, and landing impact n sub z limits. The significant findings are included.
Astephen, J L; Deluzio, K J
2005-02-01
Osteoarthritis of the knee is related to many correlated mechanical factors that can be measured with gait analysis. Gait analysis results in large data sets. The analysis of these data is difficult due to the correlated, multidimensional nature of the measures. A multidimensional model that uses two multivariate statistical techniques, principal component analysis and discriminant analysis, was used to discriminate between the gait patterns of the normal subject group and the osteoarthritis subject group. Nine time varying gait measures and eight discrete measures were included in the analysis. All interrelationships between and within the measures were retained in the analysis. The multidimensional analysis technique successfully separated the gait patterns of normal and knee osteoarthritis subjects with a misclassification error rate of <6%. The most discriminatory feature described a static and dynamic alignment factor. The second most discriminatory feature described a gait pattern change during the loading response phase of the gait cycle. The interrelationships between gait measures and between the time instants of the gait cycle can provide insight into the mechanical mechanisms of pathologies such as knee osteoarthritis. These results suggest that changes in frontal plane loading and alignment and the loading response phase of the gait cycle are characteristic of severe knee osteoarthritis gait patterns. Subsequent investigations earlier in the disease process may suggest the importance of these factors to the progression of knee osteoarthritis.
Nishino, Katsutoshi; Omori, Go; Koga, Yoshio; Kobayashi, Koichi; Sakamoto, Makoto; Tanabe, Yuji; Tanaka, Masaei; Arakawa, Masaaki
2015-07-01
We recently developed a new method for three-dimensional evaluation of mechanical factors affecting knee joint in order to help identify factors that contribute to the progression of knee osteoarthritis (KOA). This study aimed to verify the clinical validity of our method by evaluating knee joint dynamics during gait. Subjects were 41 individuals (14 normal knees; 8 mild KOAs; 19 severe KOAs). The positions of skin markers attached to the body were captured during gait, and bi-planar X-ray images of the lower extremities were obtained in standing position. The positional relationship between the markers and femorotibial bones was determined from the X-ray images. Combining this relationship with gait capture allowed for the estimation of relative movement between femorotibial bones. We also calculated the point of intersection of loading axis of knee on the tibial proximal surface (LAK point) to analyze knee joint dynamics. Knee flexion range in subjects with severe KOA during gait was significantly smaller than that in those with normal knees (p=0.011), and knee adduction in those with severe KOA was significantly larger than in those with mild KOA (p<0.000). LAK point was locally loaded on the medial compartment of the tibial surface as KOA progressed, with LAK point of subjects with severe KOA rapidly shifting medially during loading response. Local loading and medial shear force were applied to the tibial surface during stance phase as medial KOA progressed. Our findings suggest that our method is useful for the quantitative evaluation of mechanical factors that affect KOA progression. Copyright © 2015 Elsevier B.V. All rights reserved.
Shuttle remote manipulator system mission preparation and operations
NASA Technical Reports Server (NTRS)
Smith, Ernest E., Jr.
1989-01-01
The preflight planning, analysis, procedures development, and operations support for the Space Transportation System payload deployment and retrieval missions utilizing the Shuttle Remote Manipulator System are summarized. Analysis of the normal operational loads and failure induced loads and motion are factored into all procedures. Both the astronaut flight crews and the Mission Control Center flight control teams receive considerable training for standard and mission specific operations. The real time flight control team activities are described.
Wang, Shibo; Niu, Chengchao
2016-01-01
In this work, the plane-on-plane torsional fretting tribological behavior of polytetrafluoroethylene (PTFE) was studied. A model of a rigid, flat-ended punch acting on an elastic half-space was built according to the experimental conditions. The results indicate that the shape of T–θ curves was influenced by both the torsional angle and the normal load. The torsion friction torque and wear rate of PTFE exponentially decreased when the torsion angle rose. The torsional torque increased from 0.025 N·m under a normal load of 43 N to 0.082 N·m under a normal load of 123 N. With sequentially increasing normal load, the value of torque was maintained. With rising normal load, the wear mass loss of PTFE disks was increased and the wear rate was decreased. Good agreement was found with the calculated torque according to the model and the experimental torque except for that under a normal load of 163 N. The difference under a normal load of 163 N was caused by the coefficient of friction. Usually the coefficient of friction of a polymer decreases with increasing normal load, whereas a constant coefficient of friction was applied in the model. PMID:26799324
Modelling soil properties in a crop field located in Croatia
NASA Astrophysics Data System (ADS)
Bogunovic, Igor; Pereira, Paulo; Millan, Mesic; Percin, Aleksandra; Zgorelec, Zeljka
2016-04-01
Development of tillage activities had negative effects on soil quality as destruction of soil horizons, compacting and aggregates destruction, increasing soil erosion and loss of organic matter. For a better management in order to mitigate the effects of intensive soil management in land degradation it is fundamental to map the spatial distribution of soil properties (Brevik et al., 2016). The understanding the distribution of the variables in space is very important for a sustainable management, in order to identify areas that need a potential intervention and decrease the economic losses (Galiati et al., 2016). The objective of this work is study the spatial distribution of some topsoil properties as clay, fine silt, coarse silt, fine sand, coarse sand, penetration resistance, moisture and organic matter in a crop field located in Croatia. A grid with 275x25 (625 m2) was designed and a total of 48 samples were collected. Previous to data modelling, data normality was checked using the Shapiro wilk-test. As in previous cases (Pereira et al., 2015), data did not followed the normal distribution, even after a logarithmic (Log), square-root, and box cox transformation. Thus, for modeling proposes, we used the log transformed data, since was the closest to the normality. In order to identify groups among the variables we applied a principal component analysis (PCA), based on the correlation matrix. On average clay content was 15.47% (±3.23), fine silt 24.24% (±4.08), coarse silt 35.34% (±3.12), fine sand 20.93% (±4.68), coarse sand 4.02% (±1.69), penetration resistance 0.66 MPa (±0.28), organic matter 1.51% (±0.25) and soil moisture 32.04% (±3.27). The results showed that the PCA identified three factors explained at least one of the variables. The first factor had high positive loadings in soil clay, fine silt and organic matter and a high negative loading in fine sand. The second factor had high positive loadings in coarse sand and moisture and a high negative loading in coarse silt. Finally, the factor 3 had a positive loading in penetration resistance. The loadings of these three factors were mapped using ordinary kriging method. The analysis of incremental spatial correlation identified that the highest spatial correlation in the factor 1 was identified at 41.87 m, in factor 2 at 75.61 m and factor 3 at 143.9 m. In the case of factor 2, the maximum peak of spatial autocorrelation was significant at a p<0.05. This showed that the variable has a random distribution, as confirmed with the Moran's I spatial correlation analysis. In relation to the other factors the maximum peaks were significantly clustered at a p<0.001. These results suggested that the each factor has a different spatial pattern and the studied soil properties explained by each factor had a different spatial distribution. References Breivik, E., Baumgarten, A., Calzolari, C., Miller, B., Pereira, P., Kabala, C., Jordán, A. Soil mapping, classification, and modelling: history and future directions. Geoderma, 264, Part B, 256-274. Galiati, A., Gristina, L., Crescimanno, Barone, E., Novara, A. (2016) Towards more efficient incentives for agri-environment measures in degraded and eroded vineyards. Land Degradation and Development, DOI: 10.1002/ldr.2389 Pereira, P., Cerdà, A., Úbeda, X., Mataix-Solera, J. Arcenegui, V., Zavala, L. (2015) Modelling the impacts of wildfire on ash thickness in a short-term period, Land Degradation and Development, 26, 180-192.
Platelet lysate and chondroitin sulfate loaded contact lenses to heal corneal lesions.
Sandri, Giuseppina; Bonferoni, Maria Cristina; Rossi, Silvia; Delfino, Alessio; Riva, Federica; Icaro Cornaglia, Antonia; Marrubini, Giorgio; Musitelli, Giorgio; Del Fante, Claudia; Perotti, Cesare; Caramella, Carla; Ferrari, Franca
2016-07-25
Hemoderivative tear substitutes contain various ephiteliotrophic factors, such as growth factors (GF), involved in ocular surface homeostasis without immunogenic properties. The aim of the present work was the loading of platelet lysate into contact lenses to improve the precorneal permanence of platelet lysate growth factors on the ocular surface to enhance the treatment of corneal lesions. To this purpose, chondroitin sulfate, a sulfated glycosaminoglycan, which is normally present in the extracellular matrix, was associated with platelet lysate. In fact, chondroitin sulfate is capable of electrostatic interaction with positively charged growth factors, in particular, with bFGF, IGF, VEGF, PDGF and TGF-β, resulting in their stabilization and reduced degradation in solution. In the present work, various types of commercially available contact lenses have been loaded with chondroitin sulfate or chondroitin sulfate in association with platelet lysate to achieve a release of growth factors directly onto the corneal surface lesions. One type of contact lenses (PureVision(®)) showed in vitro good proliferation properties towards corneal cells and were able to enhance cut closure in cornea constructs. Copyright © 2016 Elsevier B.V. All rights reserved.
Blade Pressure Distribution for a Moderately Loaded Propeller.
1980-09-01
lifting surface, ft 2 s chordwise location as fraction of chord length t time , sec t maximum thickness of blade, ft0 U free stream velocity, ft/sec (design...developed in Reference 1, it takes into account the quadratic form of the Bernoulli equation, since the pertubation velocities are some- times of the...normal derivatives at the loading and control point, respectively. It should be noted that the time factor has been eliminated from both sides of Eq. (3
Code of Federal Regulations, 2014 CFR
2014-01-01
... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false General. 23.321 Section 23.321 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS... General. (a) Flight load factors represent the ratio of the aerodynamic force component (acting normal to...
Code of Federal Regulations, 2012 CFR
2012-01-01
... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false General. 23.321 Section 23.321 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS... General. (a) Flight load factors represent the ratio of the aerodynamic force component (acting normal to...
Code of Federal Regulations, 2011 CFR
2011-01-01
... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false General. 23.321 Section 23.321 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS... General. (a) Flight load factors represent the ratio of the aerodynamic force component (acting normal to...
Fracture mechanics analysis for various fiber/matrix interface loadings
NASA Technical Reports Server (NTRS)
Naik, R. A.; Crews, J. H., Jr.
1991-01-01
Fiber/matrix (F/M) cracking was analyzed to provide better understanding and guidance in developing F/M interface fracture toughness tests. Two configurations, corresponding to F/M cracking at a broken fiber and at the free edge, were investigated. The effects of mechanical loading, thermal cooldown, and friction were investigated. Each configuration was analyzed for two loadings: longitudinal and normal to the fiber. A nonlinear finite element analysis was performed to model friction and slip at the F/M interface. A new procedure for fitting a square-root singularity to calculated stresses was developed to determine stress intensity factors (K sub I and K sub II) for a bimaterial interface crack. For the case of F/M cracking at a broken fiber with longitudinal loading, crack tip conditions were strongly influenced by interface friction. As a result, an F/M interface toughness test based on this case was not recommended because nonlinear data analysis methods would be required. For the free edge crack configuration, both mechanical and thermal loading caused crack opening, thereby avoiding frictional effects. A F/M interface toughness test based on this configuration would provide data for K(sub I)/K(sub II) ratios of about 0.7 and 1.6 for fiber and radial normal loading, respectively. However, thermal effects must be accounted for in the data analysis.
Fracture mechanics analysis for various fiber/matrix interface loadings
NASA Technical Reports Server (NTRS)
Naik, Rajiv A.; Crews, John H., Jr.
1992-01-01
Fiber/matrix (F/M) cracking was analyzed to provide better understanding and guidance in developing F/M interface fracture toughness tests. Two configurations, corresponding to F/M cracking at a broken fiber and at the free edge, were investigated. The effects of mechanical loading, thermal cooldown, and friction were investigated. Each configuration was analyzed for two loadings: longitudinal and normal to the fiber. A nonlinear finite element analysis was performed to model friction and slip at the F/M interface. A new procedure for fitting a square-root singularity to calculated stresses was developed to determine stress intensity factors (K sub I and K sub II) for a bimaterial interface crack. For the case of F/M cracking at a broken fiber with longitudinal loading, crack tip conditions were strongly influenced by interface friction. As a result, an F/M interface toughness test based on this case was not recommended because nonlinear data analysis methods would be required. For the free edge crack configuration, both mechanical and thermal loading caused crack opening, theory avoiding fractional effects. A F/M interface toughness test based on this configuration would provide data for K(sub I/K(sub II) ratios of about 0.7 and 1.6 for fiber and radial normal loading, respectively. However, thermal effects must be accounted for in the data analysis.
Fracture mechanics analysis for various fiber/matrix interface loadings
NASA Technical Reports Server (NTRS)
Naik, R. A.; Crews, J. H., Jr.
1991-01-01
Fiber/matrix (F/M) cracking was analyzed to provide better understanding and guidance in developing F/M interface fracture toughness tests. Two configurations, corresponding to F/M cracking at a broken fiber and at the free edge, were investigated. The effects of mechanical loading, thermal cooldown, and friction were investigated. Each configuration was analyzed for two loadings: longitudinal and normal to the fiber. A nonlinear finite element analysis was performed to model friction and slip at the F/M interface. A new procedure for fitting a square-root singularity to calculated stresses was developed to determine stress intensity factors (K sub I and K sub II) for a bimaterial interface crack. For the case of F/M cracking at a broken fiber with longitudinal loading, crack tip conditions were strongly influenced by interface friction. As a result, an F/M interface toughness test based on this case was not recommended because nonlinear data analysis methods would be required. For the free edge crack configuration, both mechanical and thermal loading caused crack opening, thereby avoiding frictional effects. An F/M interface toughness test based on this configuration would provide data for K(sub I)/K(sub II) ratios of about 0.7 and 1.6 for fiber and radial normal loading, respectively. However, thermal effects must be accounted for in the data analysis.
A root-mean-square approach for predicting fatigue crack growth under random loading
NASA Technical Reports Server (NTRS)
Hudson, C. M.
1981-01-01
A method for predicting fatigue crack growth under random loading which employs the concept of Barsom (1976) is presented. In accordance with this method, the loading history for each specimen is analyzed to determine the root-mean-square maximum and minimum stresses, and the predictions are made by assuming the tests have been conducted under constant-amplitude loading at the root-mean-square maximum and minimum levels. The procedure requires a simple computer program and a desk-top computer. For the eleven predictions made, the ratios of the predicted lives to the test lives ranged from 2.13 to 0.82, which is a good result, considering that the normal scatter in the fatigue-crack-growth rates may range from a factor of two to four under identical loading conditions.
NASA Astrophysics Data System (ADS)
Li, Jing; Zhang, Zhong-ping; Li, Chun-wang
2018-03-01
This paper modified an Armstrong-Frederick-type plasticity model for investigating the stable cyclic deformation behavior of metallic materials with different sensitivity to nonproportional loadings. In the modified model, the nonproportionality factor and nonproportional cyclic hardening coefficient coupled with the Jiang-Sehitoglu incremental plasticity model were used to estimate the stable stress-strain responses of the two materials (1045HR steel and 304 stainless steel) under various tension-torsion strain paths. A new equation was proposed to calculate the nonproportionality factor on the basis of the minimum normal strain range. Procedures to determine the minimum normal strain range were presented for general multiaxial loadings. Then, the modified model requires only the cyclic strain hardening exponent and cyclic strength coefficient to determine the material constants. It is convenient for predicting the stable stress-strain responses of materials in engineering application. Comparisons showed that the modified model can reflect the effect of nonproportional cyclic hardening well.
NASA Astrophysics Data System (ADS)
Glass, Dean E.; Olah, George A.; Prakash, G. K. Surya
2017-06-01
For the large scale fuel cell manufacture, the catalyst loading and layer thickness are critical factors affecting the performance and cost of membrane electrode assemblies (MEAs). The influence of catalyst layer thicknesses at the anode of a PEM based direct methanol fuel cell (DMFC) has been investigated. Catalysts were applied with the drawdown method with varied thicknesses ranging from 1 mil to 8 mils (1 mil = 25.4 μm) with a Pt/Ru anode loading of 0.25 mg cm-2 to 2.0 mg cm-2. The MEAs with the thicker individual layers (8 mils and 4 mils) performed better overall compared to the those with the thinner layers (1 mil and painted). The peak power densities for the different loading levels followed an exponential decrease of Pt/Ru utilization at the higher loading levels. The highest power density achieved was 49 mW cm-2 with the 4 mil layers at 2.0 mg cm-2 catalyst loading whereas the highest normalized power density was 116 mW mg-1 with the 8 mil layers at 0.25 mg cm-2 loading. The 8 mil drawdowns displayed a 50% and 23% increase in normalized power density compared to the 1 mil drawdowns at 0.25 mg cm-2 and 0.5 mg cm-2 loadings, respectively.
Variations of a global constraint factor in cracked bodies under tension and bending loads
NASA Technical Reports Server (NTRS)
Newman, J. C., Jr.; Crews, J. H., Jr.; Bigelow, C. A.; Dawicke, D. S.
1994-01-01
Elastic-plastic finite-element analyses were used to calculate stresses and displacements around a crack in finite-thickness plates for an elastic-perfectly plastic material. Middle- and edge-crack specimens were analyzed under tension and bending loads. Specimens were 1.25 to 20 mm thick with various widths and crack lengths. A global constraint factor alpha(sub g), an averaged normal-stress to flow-stress ratio over the plastic region, was defined to simulate three-dimensional (3D) effects in two-dimensional (2D) models. For crack lengths and uncracked ligament lengths greater than four times the thickness, the global constraint factor was found to be nearly a unique function of a normalized stress-intensity factor (related to plastic-zone size to thickness ratio) from small- to large-scale yielding conditions for various specimen types and thickness. For crack length-to-thickness ratios less than four, the global constraint factor was specimen type, crack length and thickness dependent. Using a 2D strip-yield model and the global constraint factors, plastic-zone sizes and crack-tip displacements agreed reasonably well with the 3D analyses. For a thin sheet aluminum alloy, the critical crack-tip-opening angle during stable tearing was found to be independent of specimen type and crack length for crack length-to-thickness ratios greater than 4.
Hydrodynamic lubrication of rigid nonconformal contacts in combined rolling and normal motion
NASA Technical Reports Server (NTRS)
Ghosh, M. K.; Hamrock, B. J.; Brewe, D. E.
1984-01-01
A numerical solution to the problem of hydrodynamic lubrication of rigid point contacts with an isoviscous, incompressible lubricant was obtained. The hydrodynamic load-carrying capacity under unsteady (or dynamic) conditions arising from the combined effects of squeeze motion superposed upon the entraining motion was determined for both normal approach and separation. Superposed normal motion considerably increases net load-carrying capacity during normal approach and substantially reduces net load-carrying capacity during separation. Geometry was also found to have a significant influence on the dynamic load-carrying capacity. The ratio of dynamic to steady state load-carrying capacity increases with increasing geometry parameter for normal approach and decreases during separation. The cavitation (film rupture) boundary is also influenced significantly by the normal motion, moving downstream during approach and upstream during separation. For sufficiently high normal separation velocity the rupture boundary may even move upstream of the minimum-film-thickness position. Sixty-three cases were used to derive a functional relationship for the ratio of the dynamic to steady state load-carrying capacity in terms of the dimensionless normal velocity parameter (incorporating normal velocity, entraining velocity, and film thickness) and the geometry parameter.
Hydrodynamic lubrication of rigid nonconformal contacts in combined rolling and normal motion
NASA Technical Reports Server (NTRS)
Ghosh, M. K.; Hamrock, B. J.; Brewe, D.
1985-01-01
A numerical solution to the problem of hydrodynamic lubrication of rigid point contacts with an isoviscous, incompressible lubricant was obtained. The hydrodynamic load-carrying capacity under unsteady (or dynamic) conditions arising from the combined effects of squeeze motion superposed upon the entraining motion was determined for both normal approach and separation. Superposed normal motion considerably increases net load-carrying capacity during normal approach and substantially reduces net load-carrying capacity during separation. Geometry was also found to have a significant influence on the dynamic load-carrying capacity. The ratio of dynamic to steady state load-carrying capacity increases with increasing geometry parameter for normal approach and decreases during separation. The cavitation (film rupture) boundary is also influenced significantly by the normal motion, moving downstream during approach and upstream during separation. For sufficiently high normal separation velocity the rupture boundary may even move upstream of the minimum-film-thickness position. Sixty-three cases were used to derive a functional relationship for the ratio of the dynamic to steady state load-carrying capacity in terms of the dimensionless normal velocity parameter (incorporating normal velocity, entraining velocity, and film thickness) and the geometry parameter.
Tensmeyer, Daniel F; Gustafson, Peter A; Jastifer, James R; Patel, Bipin; Chess, Joseph L
2015-11-01
The biomechanical performance of internal fracture fixation depends on several factors. One measure of performance is the strength of the construct. The objective of this biomechanical study was to identify the effect of load obliquity on the strength of locking and nonlocking plate and screw constructs. For this study, plates and screws were fixed to synthetic osteoporotic bone that had a 1 mm thick synthetic cortical shell. An 8-hole, 3.5 mm thick hybrid plate was fixed with either two 3.5 mm major diameter locking screws or two 4.0 mm major diameter cancellous screws. Forces were applied at 0, 45, and 90 degrees to the plate normal. Eight specimens were loaded to failure for each group. When loads were applied normal to the plate, the nonlocking construct failed initially at higher loads (123.2 ± 13.2 N) than the locking construct (108.7 ± 7.6 N, P = 0.020). For oblique loads, the locking construct failed at higher mean loads but the difference of means was not statistically significant (167.7 ± 14.9 N compared to 154.2 ± 9.4 N, P = 0.052). For loads parallel to the plate, the locking construct was much stronger than the nonlocking construct (1591 ± 227 N compared to 913 ± 237 N, P < 0.001). Stiffness and Energy outcomes are also compared. Copyright © 2015 IPEM. Published by Elsevier Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
Nandi, P. S.; Spodick, D. H.
1977-01-01
The time course of the recovery period was characterized by noninvasive measurements after 4 minute bicycle exercise at 3 separate work loads in volunteers with normal peak responses. Most responses started immediately to return toward resting control values. Left ventricular ejection time and stroke volume change are discussed. Changes in pre-ejection period were determined by changes in isovolume contraction time, and factors affecting the degree and rate of return are considered. The rates of change in the ejection time index and in the ratio pre-ejection period/left ventricular ejection time were virtually independent of load throughout most of recovery.
Children's Speech Perception in Noise: Evidence for Dissociation From Language and Working Memory.
Magimairaj, Beula M; Nagaraj, Naveen K; Benafield, Natalie J
2018-05-17
We examined the association between speech perception in noise (SPIN), language abilities, and working memory (WM) capacity in school-age children. Existing studies supporting the Ease of Language Understanding (ELU) model suggest that WM capacity plays a significant role in adverse listening situations. Eighty-three children between the ages of 7 to 11 years participated. The sample represented a continuum of individual differences in attention, memory, and language abilities. All children had normal-range hearing and normal-range nonverbal IQ. Children completed the Bamford-Kowal-Bench Speech-in-Noise Test (BKB-SIN; Etymotic Research, 2005), a selective auditory attention task, and multiple measures of language and WM. Partial correlations (controlling for age) showed significant positive associations among attention, memory, and language measures. However, BKB-SIN did not correlate significantly with any of the other measures. Principal component analysis revealed a distinct WM factor and a distinct language factor. BKB-SIN loaded robustly as a distinct 3rd factor with minimal secondary loading from sentence recall and short-term memory. Nonverbal IQ loaded as a 4th factor. Results did not support an association between SPIN and WM capacity in children. However, in this study, a single SPIN measure was used. Future studies using multiple SPIN measures are warranted. Evidence from the current study supports the use of BKB-SIN as clinical measure of speech perception ability because it was not influenced by variation in children's language and memory abilities. More large-scale studies in school-age children are needed to replicate the proposed role played by WM in adverse listening situations.
NASA Technical Reports Server (NTRS)
Miller, Eric J.; Cruz, Josue; Lung, Shun-Fat; Kota, Sridhar; Ervin, Gregory; Lu, Kerr-Jia; Flick, Pete
2016-01-01
A seamless adaptive compliant trailing edge (ACTE) flap was demonstrated in flight on a Gulfstream III aircraft at the NASA Armstrong Flight Research Center. The trailing edge flap was deflected between minus 2 deg up and plus 30 deg down in flight. The safety-of-flight parameters for the ACTE flap experiment require that flap-to-wing interface loads be sensed and monitored in real time to ensure that the structural load limits of the wing are not exceeded. The attachment fittings connecting the flap to the aircraft wing rear spar were instrumented with strain gages and calibrated using known loads for measuring hinge moment and normal force loads in flight. The safety-of-flight parameters for the ACTE flap experiment require that flap-to-wing interface loads be sensed and monitored in real time to ensure that the structural load limits of the wing are not exceeded. The attachment fittings connecting the flap to the aircraft wing rear spar were instrumented with strain gages and calibrated using known loads for measuring hinge moment and normal force loads in flight. The interface hardware instrumentation layout and load calibration are discussed. Twenty-one applied calibration test load cases were developed for each individual fitting. The 2-sigma residual errors for the hinge moment was calculated to be 2.4 percent, and for normal force was calculated to be 7.3 percent. The hinge moment and normal force generated by the ACTE flap with a hinge point located at 26-percent wing chord were measured during steady state and symmetric pitch maneuvers. The loads predicted from analysis were compared to the loads observed in flight. The hinge moment loads showed good agreement with the flight loads while the normal force loads calculated from analysis were over-predicted by approximately 20 percent. Normal force and hinge moment loads calculated from the pressure sensors located on the ACTE showed good agreement with the loads calculated from the installed strain gages.
Is Hand Selection Modulated by Cognitive-perceptual Load?
Liang, Jiali; Wilkinson, Krista; Sainburg, Robert L
2018-01-15
Previous studies proposed that selecting which hand to use for a reaching task appears to be modulated by a factor described as "task difficulty". However, what features of a task might contribute to greater or lesser "difficulty" in the context of hand selection decisions has yet to be determined. There has been evidence that biomechanical and kinematic factors such as movement smoothness and work can predict patterns of selection across the workspace, suggesting a role of predictive cost analysis in hand-selection. We hypothesize that this type of prediction for hand-selection should recruit substantial cognitive resources and thus should be influenced by cognitive-perceptual loading. We test this hypothesis by assessing the role of cognitive-perceptual loading on hand selection decisions, using a visual search task that presents different levels of difficulty (cognitive-perceptual load), as established in previous studies on overall response time and efficiency of visual search. Although the data are necessarily preliminary due to small sample size, our data suggested an influence of cognitive-perceptual load on hand selection, such that the dominant hand was selected more frequently as cognitive load increased. Interestingly, cognitive-perceptual loading also increased cross-midline reaches with both hands. Because crossing midline is more costly in terms of kinematic and kinetic factors, our findings suggest that cognitive processes are normally engaged to avoid costly actions, and that the choice not-to-cross midline requires cognitive resources. Copyright © 2017 IBRO. Published by Elsevier Ltd. All rights reserved.
Normal axial alignment of the lower extremity and load-bearing distribution at the knee.
Hsu, R W; Himeno, S; Coventry, M B; Chao, E Y
1990-06-01
Based on a series of 120 normal subjects of different gender and age, the geometry of the knee joint was analyzed using a full-length weight-bearing roentgenogram of the lower extremity. A special computer program based on the theory of a rigid body spring model was applied to calculate the important anatomic and biomechanical factors of the knee joint. The tibiofemoral mechanical angle was 1.2 degrees varus. Hence, it is difficult to rationalize the 3 degree varus placement of the tibial component in total knee arthroplasty suggested by some authors. The distal femoral anatomic valgus (measured from the lower one-half of the femur) was 4.2 degrees in reference to its mechanical axis. This angle became 4.9 degrees when the full-length femoral anatomic axis was used. When simulating a one-legged weight-bearing stance by shifting the upper-body gravity closer to the knee joint, 75% of the knee joint load passed through the medial tibial plateau. The knee joint-line obliquity was more varus in male subjects. The female subjects had a higher peak joint pressure and a greater patello-tibial Q angle. Age had little effect on the factors relating to axial alignment of the lower extremity and load transmission through the knee joint.
Normalization of load and clearance effects in ball-in-socket-like replacements.
Ciavarella, M; Strozzi, A; Baldini, A; Giacopini, M
2007-08-01
A normalizing loading parameter useful in summarising the mechanical response of plane pin-in-plate-like contacts is extended to axisymmetric ball-in-socket-like contacts. An example addressing a compliant layered artificial hip joint is presented, and the usefulness of the normalizing loading parameter is evidenced.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hodge, B. M.; Lew, D.; Milligan, M.
2013-01-01
Load forecasting in the day-ahead timescale is a critical aspect of power system operations that is used in the unit commitment process. It is also an important factor in renewable energy integration studies, where the combination of load and wind or solar forecasting techniques create the net load uncertainty that must be managed by the economic dispatch process or with suitable reserves. An understanding of that load forecasting errors that may be expected in this process can lead to better decisions about the amount of reserves necessary to compensate errors. In this work, we performed a statistical analysis of themore » day-ahead (and two-day-ahead) load forecasting errors observed in two independent system operators for a one-year period. Comparisons were made with the normal distribution commonly assumed in power system operation simulations used for renewable power integration studies. Further analysis identified time periods when the load is more likely to be under- or overforecast.« less
NASA Technical Reports Server (NTRS)
Abraham, Arick Reed A.; Johnson, Kenneth L.; Nichols, Charles T.; Saulsberry, Regor L.; Waller, Jess M.
2012-01-01
Broadband modal acoustic emission (AE) data were acquired during intermittent load hold tensile test profiles on Toray T1000G carbon fiber-reinforced epoxy (C/Ep) single tow specimens. A novel trend seeking statistical method to determine the onset of significant AE was developed, resulting in more linear decreases in the Felicity ratio (FR) with load, potentially leading to more accurate failure prediction. The method developed uses an exponentially weighted moving average (EWMA) control chart. Comparison of the EWMA with previously used FR onset methods, namely the discrete (n), mean (n (raised bar)), normalized (n%) and normalized mean (n(raised bar)%) methods, revealed the EWMA method yields more consistently linear FR versus load relationships between specimens. Other findings include a correlation between AE data richness and FR linearity based on the FR methods discussed in this paper, and evidence of premature failure at lower than expected loads. Application of the EWMA method should be extended to other composite materials and, eventually, composite components such as composite overwrapped pressure vessels. Furthermore, future experiments should attempt to uncover the factors responsible for infant mortality in C/Ep strands.
Ashton, Michael C; Lee, Kibeom; de Vries, Reinout E; Hendrickse, Joshua; Born, Marise Ph
2012-10-01
The Personality Inventory for DSM-5 (PID-5), a new measure of maladaptive personality traits, has recently been developed by the DSM-5 Personality and Personality Disorders Workgroup. The PID-5 variables were examined within the seven-factor space defined by the six HEXACO factors and the Schizotypy/Dissociation factor (Ashton & Lee, 2012) using participant samples from Canada (N = 378) and the Netherlands (N = 476). Extension analyses showed that several PID-5 facet-level scales represented each of the Honesty-Humility, Emotionality, Extraversion, Conscientiousness, and Schizotypy/Dissociation factors. In contrast, only one PID-5 scale loaded strongly on HEXACO Agreeableness, and no PID-5 scales loaded strongly on Openness to Experience. In addition, a joint factor analysis involving the PID-5 variables and facets of the Five-Factor Model was conducted in the Canadian sample and recovered a set of seven factors corresponding rather closely to the HEXACO factors plus Schizotypy/Dissociation. The authors discuss implications for the assessment and structure of normal and abnormal personality.
Optical based tactile shear and normal load sensor
Salisbury, Curt Michael
2015-06-09
Various technologies described herein pertain to a tactile sensor that senses normal load and/or shear load. The tactile sensor includes a first layer and an optically transparent layer bonded together. At least a portion of the first layer is made of optically reflective material. The optically transparent layer is made of resilient material (e.g., clear silicone rubber). The tactile sensor includes light emitter/light detector pair(s), which respectively detect either normal load or shear load. Light emitter(s) emit light that traverses through the optically transparent layer and reflects off optically reflective material of the first layer, and light detector(s) detect and measure intensity of reflected light. When a normal load is applied, the optically transparent layer compresses, causing a change in reflected light intensity. When shear load is applied, a boundary between optically reflective material and optically absorptive material is laterally displaced, causing a change in reflected light intensity.
The parameters effect on the structural performance of damaged steel box beam using Taguchi method
NASA Astrophysics Data System (ADS)
El-taly, Boshra A.; Abd El Hameed, Mohamed F.
2018-03-01
In the current study, the influence of notch or opening parameters and the positions of the applied load on the structural performance of steel box beams up to failure was investigated using Finite Element analysis program, ANSYS. The Taguchi-based design of experiments technique was used to plan the current study. The plan included 12 box steel beams; three intact beams, and nine damaged beams (with opening) in the beams web. The numerical studies were conducted under varying the spacing between the two concentrated point loads (location of applied loads), the notch (opening) position, and the ratio between depth and width of the notch with a constant notch area. According to Taguchi analysis, factor X (location of the applied loads) was found the highest contributing parameters for the variation of the ultimate load, vertical deformation, shear stresses, and the compressive normal stresses.
Research on the Mechanism of In-Plane Vibration on Friction Reduction
Wang, Peng; Ni, Hongjian; Wang, Ruihe; Liu, Weili; Lu, Shuangfang
2017-01-01
A modified model for predicting the friction force between drill-string and borehole wall under in-plane vibrations was developed. It was found that the frictional coefficient in sliding direction decreased significantly after applying in-plane vibration on the bottom specimen. The friction reduction is due to the direction change of friction force, elastic deformation of surface asperities and the change of frictional coefficient. Normal load, surface topography, vibration direction, velocity ratio and interfacial shear factor are the main influence factors of friction force in sliding direction. Lower driving force can be realized for a pair of determinate rubbing surfaces under constant normal load by setting the driving direction along the minimum arithmetic average attack angle direction, and applying intense longitudinal vibration on the rubbing pair. The modified model can significantly improve the accuracy in predicting frictional coefficient under vibrating conditions, especially under the condition of lower velocity ratio. The results provide a theoretical gist for friction reduction technology by vibrating drill-string, and provide a reference for determination of frictional coefficient during petroleum drilling process, which has great significance for realizing digitized and intelligent drilling. PMID:28862679
Esmaeili, Alireza; Stewart, Andrew M; Hopkins, William G; Elias, George P; Lazarus, Brendan H; Rowell, Amber E; Aughey, Robert J
2018-01-01
Aim: The sit and reach test (S&R), dorsiflexion lunge test (DLT), and adductor squeeze test (AST) are commonly used in weekly musculoskeletal screening for athlete monitoring and injury prevention purposes. The aim of this study was to determine the normal week to week variability of the test scores, individual differences in variability, and the effects of training load on the scores. Methods: Forty-four elite Australian rules footballers from one club completed the weekly screening tests on day 2 or 3 post-main training (pre-season) or post-match (in-season) over a 10 month season. Ratings of perceived exertion and session duration for all training sessions were used to derive various measures of training load via both simple summations and exponentially weighted moving averages. Data were analyzed via linear and quadratic mixed modeling and interpreted using magnitude-based inference. Results: Substantial small to moderate variability was found for the tests at both season phases; for example over the in-season, the normal variability ±90% confidence limits were as follows: S&R ±1.01 cm, ±0.12; DLT ±0.48 cm, ±0.06; AST ±7.4%, ±0.6%. Small individual differences in variability existed for the S&R and AST (factor standard deviations between 1.31 and 1.66). All measures of training load had trivial effects on the screening scores. Conclusion: A change in a test score larger than the normal variability is required to be considered a true change. Athlete monitoring and flagging systems need to account for the individual differences in variability. The tests are not sensitive to internal training load when conducted 2 or 3 days post-training or post-match, and the scores should be interpreted cautiously when used as measures of recovery.
Jen Y. Liu; S. Cheng
1979-01-01
A plane-stress analysis of orthotropic or isotropic beams is presented. The loading conditions considered are: (1) a concentrated normal load arbitrarily located on the beam, and (2) a distributed normal load covering an arbitrary length of the beam. exhibit close agreement with existing experimental data from Sitka spruce beams. Other loading conditions can similarly...
Geotribology - Friction, wear, and lubrication of faults
NASA Astrophysics Data System (ADS)
Boneh, Yuval; Reches, Ze'ev
2018-05-01
We introduce here the concept of Geotribology as an approach to study friction, wear, and lubrication of geological systems. Methods of geotribology are applied here to characterize the friction and wear associated with slip along experimental faults composed of brittle rocks. The wear in these faults is dominated by brittle fracturing, plucking, scratching and fragmentation at asperities of all scales, including 'effective asperities' that develop and evolve during the slip. We derived a theoretical model for the rate of wear based on the observation that the dynamic strength of brittle materials is proportional to the product of load stress and loading period. In a slipping fault, the loading period of an asperity is inversely proportional to the slip velocity, and our derivations indicate that the wear-rate is proportional to the ratio of [shear-stress/slip-velocity]. By incorporating the rock hardness data into the model, we demonstrate that a single, universal function fits wear data of hundreds of experiments with granitic, carbonate and sandstone faults. In the next step, we demonstrate that the dynamic frictional strength of experimental faults is well explained in terms of the tribological parameter PV factor (= normal-stress · slip-velocity). This factor successfully delineates weakening and strengthening regimes of carbonate and granitic faults. Finally, our analysis revealed a puzzling observation that wear-rate and frictional strength have strikingly different dependencies on the loading conditions of normal-stress and slip-velocity; we discuss sources for this difference. We found that utilization of tribological tools in fault slip analyses leads to effective and insightful results.
Chen, Guobao; Lv, Yonggang
2015-01-01
Electrospun nanofibers have been extensively used in growth factor delivery and regenerative medicine due to many advantages including large surface area to volume ratio, high porosity, excellent loading capacity, ease of access and cost effectiveness. Their relatively large surface area is helpful for cell adhesion and growth factor loading, while storage and release of growth factor are essential to guide cellular behaviors and tissue formation and organization. In bone tissue engineering, growth factors are expected to transmit signals that stimulate cellular proliferation, migration, differentiation, metabolism, apoptosis and extracellular matrix (ECM) deposition. Bolus administration is not always an effective method for the delivery of growth factors because of their rapid diffusion from the target site and quick deactivation. Therefore, the integration of controlled release strategy within electrospun nanofibers can provide protection for growth factors against in vivo degradation, and can manipulate desired signal at an effective level with extended duration in local microenvironment to support tissue regeneration and repair which normally takes a much longer time. In this review, we provide an overview of growth factor delivery using biomimetic electrospun nanofiber scaffolds in bone tissue engineering. It begins with a brief introduction of different kinds of polymers that were used in electrospinning and their applications in bone tissue engineering. The review further focuses on the nanofiber-based growth factor delivery and summarizes the strategies of growth factors loading on the nanofiber scaffolds for bone tissue engineering applications. The perspectives on future challenges in this area are also pointed out.
Zekveld, Adriana A; Kramer, Sophia E; Festen, Joost M
2011-01-01
The aim of the present study was to evaluate the influence of age, hearing loss, and cognitive ability on the cognitive processing load during listening to speech presented in noise. Cognitive load was assessed by means of pupillometry (i.e., examination of pupil dilation), supplemented with subjective ratings. Two groups of subjects participated: 38 middle-aged participants (mean age = 55 yrs) with normal hearing and 36 middle-aged participants (mean age = 61 yrs) with hearing loss. Using three Speech Reception Threshold (SRT) in stationary noise tests, we estimated the speech-to-noise ratios (SNRs) required for the correct repetition of 50%, 71%, or 84% of the sentences (SRT50%, SRT71%, and SRT84%, respectively). We examined the pupil response during listening: the peak amplitude, the peak latency, the mean dilation, and the pupil response duration. For each condition, participants rated the experienced listening effort and estimated their performance level. Participants also performed the Text Reception Threshold (TRT) test, a test of processing speed, and a word vocabulary test. Data were compared with previously published data from young participants with normal hearing. Hearing loss was related to relatively poor SRTs, and higher speech intelligibility was associated with lower effort and higher performance ratings. For listeners with normal hearing, increasing age was associated with poorer TRTs and slower processing speed but with larger word vocabulary. A multivariate repeated-measures analysis of variance indicated main effects of group and SNR and an interaction effect between these factors on the pupil response. The peak latency was relatively short and the mean dilation was relatively small at low intelligibility levels for the middle-aged groups, whereas the reverse was observed for high intelligibility levels. The decrease in the pupil response as a function of increasing SNR was relatively small for the listeners with hearing loss. Spearman correlation coefficients indicated that the cognitive load was larger in listeners with better TRT performances as reflected by a longer peak latency (normal-hearing participants, SRT50% condition) and a larger peak amplitude and longer response duration (hearing-impaired participants, SRT50% and SRT84% conditions). Also, a larger word vocabulary was related to longer response duration in the SRT84% condition for the participants with normal hearing. The pupil response systematically increased with decreasing speech intelligibility. Ageing and hearing loss were related to less release from effort when increasing the intelligibility of speech in noise. In difficult listening conditions, these factors may induce cognitive overload relatively early or they may be associated with relatively shallow speech processing. More research is needed to elucidate the underlying mechanisms explaining these results. Better TRTs and larger word vocabulary were related to higher mental processing load across speech intelligibility levels. This indicates that utilizing linguistic ability to improve speech perception is associated with increased listening load.
Elastic-plastic deformation of a metal-matrix composite coupon with a center slot
NASA Technical Reports Server (NTRS)
Post, D.; Czarnek, R.; Joh, D.; Jo, J.; Guo, Y.
1985-01-01
A comprehensive experimental analysis of deformations of the surface of a metal-matrix specimen is reported. The specimen is a 6-ply 0 + or - 45 sub s boron-aluminum tensile coupon with a central slot. Moire interferometry is used for high-sensitivity whole-field measurements of in-plane displacements. Normal and shear strains are calculated from displacement gradients. Displacement fields are analyzed at various load levels from 15% to 95% of the failure load. Deformations of the boron fibers could be distinguished from those of the matrix. Highly localized plastic slip zones occur tangent to the ends of the slot. Shear strains and concurrent transverse compressive strains in the slip zones reach approximately 10% and 1%, respectively. Upon unloading, elastic recovery in surrounding regions causes a reverse plastic shear strain in the slip zone of about 4%. Longitudinal normal strains on the unslotted ligament peak at the slot boundary at about 1% strain. The strain concentration factor at the end of the slot decreases with load level and the advance of plasticity.
Code of Federal Regulations, 2014 CFR
2014-10-01
..., equipped with passenger car tires, the vehicle normal load on the tire shall be no greater than 94 percent..., the vehicle normal load on the tire shall be no greater than 94 percent of the load rating at the... vehicle trailer load carrying capacity information for motor vehicles with a GVWR of 4,536 kilograms (10...
Code of Federal Regulations, 2012 CFR
2012-10-01
..., equipped with passenger car tires, the vehicle normal load on the tire shall be no greater than 94 percent..., the vehicle normal load on the tire shall be no greater than 94 percent of the load rating at the... vehicle trailer load carrying capacity information for motor vehicles with a GVWR of 4,536 kilograms (10...
Code of Federal Regulations, 2011 CFR
2011-10-01
..., equipped with passenger car tires, the vehicle normal load on the tire shall be no greater than 94 percent..., the vehicle normal load on the tire shall be no greater than 94 percent of the load rating at the... vehicle trailer load carrying capacity information for motor vehicles with a GVWR of 4,536 kilograms (10...
Code of Federal Regulations, 2013 CFR
2013-10-01
..., equipped with passenger car tires, the vehicle normal load on the tire shall be no greater than 94 percent..., the vehicle normal load on the tire shall be no greater than 94 percent of the load rating at the... vehicle trailer load carrying capacity information for motor vehicles with a GVWR of 4,536 kilograms (10...
Code of Federal Regulations, 2010 CFR
2010-10-01
..., equipped with passenger car tires, the vehicle normal load on the tire shall be no greater than 94 percent..., the vehicle normal load on the tire shall be no greater than 94 percent of the load rating at the... vehicle trailer load carrying capacity information for motor vehicles with a GVWR of 4,536 kilograms (10...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-01-24
..., except federal holidays. FOR FURTHER INFORMATION CONTACT: Joe Jacobsen, FAA, Airplane and Flight Crew... protection features include limitations on angle-of- attack, normal load factor, bank angle, pitch angle, and... characteristics, and High angle-of-attack. Section Sec. 25.143, however, does not adequately ensure that the novel...
Naserkhaki, Sadegh; Jaremko, Jacob L; El-Rich, Marwan
2016-09-06
There is a large, at times contradictory, body of research relating spinal curvature to Low Back Pain (LBP). Mechanical load is considered as important factor in LBP etiology. Geometry of the spinal structures and sagittal curvature of the lumbar spine govern its mechanical behavior. Thus, understanding how inter-individual geometry particularly sagittal curvature variation affects the spinal load-sharing becomes of high importance in LBP assessment. This study calculated and compared kinematics and load-sharing in three ligamentous lumbosacral spines: one hypo-lordotic (Hypo-L) with low lordosis, one normal-lordotic (Norm-L) with normal lordosis, and one hyper-lordotic (Hyper-L) with high lordosis in flexed and extended postures using 3D nonlinear Finite Element (FE) modeling. These postures were simulated by applying Follower Load (FL) combined with flexion or extension moment. The Hypo-L spine demonstrated stiffer behavior in flexion but more flexible response to extension compared to the Norm-L spine. The excessive lordosis stiffened response of the Hyper-L spine to extension but did not affect its resistance to flexion compared to the Norm-L spine. Despite the different resisting actions of the posterior ligaments to flexion moment, the increase of disc compression was similar in all the spines leading to similar load-sharing. However, resistance of the facet joints to extension was more important in the Norm- and Hyper-L spines which reduced the disc compression. The spinal curvature strongly influenced the magnitude and location of load on the spinal components and also altered the kinematics and load-sharing particularly in extension. Consideration of the subject-specific geometry and sagittal curvature should be an integral part of mechanical analysis of the lumbar spine. Copyright © 2016 Elsevier Ltd. All rights reserved.
Homminga, J; Van-Rietbergen, B; Lochmüller, E M; Weinans, H; Eckstein, F; Huiskes, R
2004-03-01
Osteoporotic vertebral fractures typically have a gradual onset, frequently remain clinically undetected, and do not seem to be related to traumatic events. The osteoporotic vertebrae may therefore be expected to display a less "optimal" bone architecture, leading to an uneven load distribution over the bone material. We evaluated the trabecular load distribution in an osteoporotic and a healthy vertebra under normal daily loading by combining three recent innovations: high resolution computed tomography (microCT) of entire bones, microfinite element analyses (microFEA), and parallel supercomputers. Much to our surprise, the number of highly loaded trabeculae was not higher in the osteoporotic vertebra than in the healthy one under normal daily loads (8% and 9%, respectively). The osteoporotic trabeculae were more oriented in the longitudinal direction, compensating for effects of bone loss and ensuring adequate stiffness for normal daily loading. The increased orientation did, however, make the osteoporotic structure less resistant against collateral "error" loads. In this case, the number of overloaded trabeculae in the osteoporotic vertebra was higher than in the healthy one (13% and 4%, respectively). These results strengthen the paradigm of a strong relationship between bone morphology and external loads applied during normal daily life. They also indicate that vertebral fractures result from actions like forward flexion or lifting, loads that may not be "daily" but are normally not traumatic either. If future clinical imaging techniques would enable such high-resolution images to be obtained in vivo, the combination of microCT and microFEA would produce a powerful tool to diagnose osteoporosis.
Critical factors in displacement ductility assessment of high-strength concrete columns
NASA Astrophysics Data System (ADS)
Taheri, Ali; Moghadam, Abdolreza S.; Tasnimi, Abass Ali
2017-12-01
Ductility of high-strength concrete (HSC) columns with rectangular sections was assessed in this study by reviewing experimental data from the available literature. Up to 112 normal weights concrete columns with strength in the range of 50-130 MPa were considered and presented as a database. The data included the results of column testes under axial and reversed lateral loading. Displacement ductility of HSC columns was evaluated in terms of their concrete and reinforcement strengths, bar arrangement, volumetric ratio of transverse reinforcement, and axial loading. The results indicated that the confinement requirements and displacement ductility in HSC columns are more sensitive than those in normal strength concrete columns. Moreover, ductility is descended by increasing concrete strength. However, it was possible to obtain ductile behavior in HSC columns through proper confinement. Furthermore, this study casts doubt about capability of P/ A g f c' ratio that being inversely proportional to displacement ductility of HSC columns.
The Value Range of Contact Stiffness Factor between Pile and Soil Based on Penalty Function
NASA Astrophysics Data System (ADS)
Chen, Sandy H. L.; Wu, Xinliu
2018-03-01
The value range of contact stiffness factor based on penalty function is studied when we use finite element software ANSYS to analyze contact problems, take single pile and soil of a certain project for example, the normal contact between pile and soil is analyzed with 2D simplified model in horizontal load. The study shows that when adopting linear elastic model to simulate soil, the maximum contact pressure and penetration approach steady value as the contact stiffness factor increases. The reasonable value range of contact stiffness factor reduces as the underlying element thickness decreases, but the rule reverses when refers to the soil stiffness. If choose DP model to simulate soil, the stiffness factor should be magnified 100 times compares to the elastic model regardless of the soil bears small force and still in elastic deformation stage or into the plastic deformation stage. When the soil bears big force and into plastic deformation stage, the value range of stiffness factor relates to the plastic strain range of the soil, and reduces as the horizontal load increases.
Heat Load Sharing in a Capillary Pumped Loop with Multiple Evaporators and Multiple Condensers
NASA Technical Reports Server (NTRS)
Ku, Jentung
2005-01-01
This paper describes the heat load sharing function among multiple parallel evaporators in a capillary pumped loop (CPL). In the normal mode of operation, the evaporators cool the instruments by absorbing the waste heat. When an instruments is turned off, the attached evaporator can keep it warm by receiving heat from other evaporators serving the operating instruments. This is referred to as heat load sharing. A theoretical basis of heat load sharing is given first. The fact that the wicks in the powered evaporators will develop capillary pressure to force the generated vapor to flow to cold locations where the pressure is lower leads to the conclusion that heat load sharing is an inherent function of a CPL with multiple evaporators. Heat load sharing has been verified with many CPLs in ground tests. Experimental results of the Capillary Pumped Loop 3 (CAPL 3) Flight Experiment are presented in this paper. Factors that affect the amount of heat being shared are discussed. Some constraints of heat load sharing are also addressed.
Closed-form analysis of fiber-matrix interface stresses under thermo-mechanical loadings
NASA Technical Reports Server (NTRS)
Naik, Rajiv A.; Crews, John H., Jr.
1992-01-01
Closed form techniques for calculating fiber matrix (FM) interface stresses, using repeating square and diamond regular arrays, were presented for a unidirectional composite under thermo-mechanical loadings. An Airy's stress function micromechanics approach from the literature, developed for calculating overall composite moduli, was extended in the present study to compute FM interface stresses for a unidirectional graphite/epoxy (AS4/3501-6) composite under thermal, longitudinal, transverse, transverse shear, and longitudinal shear loadings. Comparison with finite element results indicate excellent agreement of the FM interface stresses for the square array. Under thermal and longitudinal loading, the square array has the same FM peak stresses as the diamond array. The square array predicted higher stress concentrations under transverse normal and longitudinal shear loadings than the diamond array. Under transverse shear loading, the square array had a higher stress concentration while the diamond array had a higher radial stress concentration. Stress concentration factors under transverse shear and longitudinal shear loadings were very sensitive to fiber volume fraction. The present analysis provides a simple way to calculate accurate FM interface stresses for both the square and diamond array configurations.
Bending strength model for internal spur gear teeth
NASA Technical Reports Server (NTRS)
Savage, Michael; Rubadeux, K. L.; Coe, H. H.
1995-01-01
Internal spur gear teeth are normally stronger than pinion teeth of the same pitch and face width since external teeth are smaller at the base. However, ring gears which are narrower have an unequal addendum or are made of a material with a lower strength than that of the meshing pinion may be loaded more critically in bending. In this study, a model for the bending strength of an internal gear tooth as a function of the applied load pressure angle is presented which is based on the inscribed Lewis constant strength parabolic beam. The bending model includes a stress concentration factor and an axial compression term which are extensions of the model for an external gear tooth. The geometry of the Lewis factor determination is presented, the iteration to determine the factor is described, and the bending strength J factor is compared to that of an external gear tooth. This strength model will assist optimal design efforts for unequal addendum gears and gears of mixed materials.
NASA Technical Reports Server (NTRS)
Thornton, Stephen V.
1993-01-01
A transonic fighter-bomber aircraft, having a swept supercritical wing with smooth variable-camber flaps was fitted with a maneuver load control (MLC) system that implements a technique to reduce the inboard bending moments in the wing by shifting the spanwise load distribution inboard as load factor increases. The technique modifies the spanwise camber distribution by automatically commanding flap position as a function of flap position, true airspeed, Mach number, dynamic pressure, normal acceleration, and wing sweep position. Flight test structural loads data were obtained for loads in both the wing box and the wing root. Data from uniformly deflected flaps were compared with data from flaps in the MLC configuration where the outboard segment of three flap segments was deflected downward less than the two inboard segments. The changes in the shear loads in the forward wing spar and at the roots of the stabilators also are presented. The camber control system automatically reconfigures the flaps through varied flight conditions. Configurations having both moderate and full trailing-edge flap deflection were tested. Flight test data were collected at Mach numbers of 0.6, 0.7, 0.8, and 0.9 and dynamic pressures of 300, 450, 600, and 800 lb/sq ft. The Reynolds numbers for these flight conditions ranged from 26 x 10(exp 6) to 54 x 10(exp 6) at the mean aerodynamic chord. Load factor increases of up to 1.0 g achieved with no increase in wing root bending moment with the MLC flap configuration.
Normalized spectral damage of a linear system over different spectral loading patterns
NASA Astrophysics Data System (ADS)
Kim, Chan-Jung
2017-08-01
Spectral fatigue damage is affected by different loading patterns; the damage may be accumulated in a different manner because the spectral pattern has an influence on stresses or strains. The normalization of spectral damage with respect to spectral loading acceleration is a novel solution to compare the accumulated fatigue damage over different spectral loading patterns. To evaluate the sensitivity of fatigue damage over different spectral loading cases, a simple notched specimen is used to conduct a uniaxial vibration test for two representative spectral patterns-random and harmonic-between 30 and 3000 Hz. The fatigue damage to the simple specimen is analyzed for different spectral loading cases using the normalized spectral damage from the measured response data for both acceleration and strain. The influence of spectral loading patterns is discussed based on these analyses.
Phan, Xuan; Grisbrook, Tiffany L; Wernli, Kevin; Stearne, Sarah M; Davey, Paul; Ng, Leo
2017-08-01
This study aimed to determine if a quantifiable relationship exists between the peak sound amplitude and peak vertical ground reaction force (vGRF) and vertical loading rate during running. It also investigated whether differences in peak sound amplitude, contact time, lower limb kinematics, kinetics and foot strike technique existed when participants were verbally instructed to run quietly compared to their normal running. A total of 26 males completed running trials for two sound conditions: normal running and quiet running. Simple linear regressions revealed no significant relationships between impact sound and peak vGRF in the normal and quiet conditions and vertical loading rate in the normal condition. t-Tests revealed significant within-subject decreases in peak sound, peak vGRF and vertical loading rate during the quiet compared to the normal running condition. During the normal running condition, 15.4% of participants utilised a non-rearfoot strike technique compared to 76.9% in the quiet condition, which was corroborated by an increased ankle plantarflexion angle at initial contact. This study demonstrated that quieter impact sound is not directly associated with a lower peak vGRF or vertical loading rate. However, given the instructions to run quietly, participants effectively reduced peak impact sound, peak vGRF and vertical loading rate.
NASA Astrophysics Data System (ADS)
Islam, Mohammad; Khalid, Yasir; Ahmad, Iftikhar; Almajid, Abdulhakim A.; Achour, Amine; Dunn, Theresa J.; Akram, Aftab; Anwar, Saqib
2018-04-01
Silicon carbide (SiC) nanoparticles (NP) and/or graphene nanoplatelets (GNP) were incorporated into the aluminum matrix through colloidal dispersion and mixing of the powders, followed by consolidation using a high-frequency induction heat sintering process. All the nanocomposite samples exhibited high densification (> 96 pct) with a maximum increase in Vickers microhardness by 92 pct relative to that of pure aluminum. The tribological properties of the samples were determined at the normal frictional forces of 10 and 50 N. At relatively low load of 10 N, the adhesive wear was found to be the predominant wear mechanism, whereas in the case of a 50 N normal load, there was significant contribution from abrasive wear possibly by hard SiC NP. From wear tests, the values for the coefficient of friction (COF) and the normalized wear rate were determined. The improvement in hardness and wear resistance may be attributed to multiple factors, including high relative density, uniform SiC and GNP dispersion in the aluminum matrix, grain refinement through GNP pinning, as well as inhibition of dislocation movement by SiC NP. The nanocomposite sample containing 10 SiC and 0.5 GNP (by wt pct) yielded the maximum wear resistance at 10 N normal load. Microstructural characterization of the nanocomposite surfaces and wear debris was performed using scanning electron microscope (SEM) and transmission electron microscope (TEM). The synergistic effect of the GNP and SiC nanostructures accounts for superior wear resistance in the aluminum matrix nanocomposites.
NASA Astrophysics Data System (ADS)
Islam, Mohammad; Khalid, Yasir; Ahmad, Iftikhar; Almajid, Abdulhakim A.; Achour, Amine; Dunn, Theresa J.; Akram, Aftab; Anwar, Saqib
2018-07-01
Silicon carbide (SiC) nanoparticles (NP) and/or graphene nanoplatelets (GNP) were incorporated into the aluminum matrix through colloidal dispersion and mixing of the powders, followed by consolidation using a high-frequency induction heat sintering process. All the nanocomposite samples exhibited high densification (> 96 pct) with a maximum increase in Vickers microhardness by 92 pct relative to that of pure aluminum. The tribological properties of the samples were determined at the normal frictional forces of 10 and 50 N. At relatively low load of 10 N, the adhesive wear was found to be the predominant wear mechanism, whereas in the case of a 50 N normal load, there was significant contribution from abrasive wear possibly by hard SiC NP. From wear tests, the values for the coefficient of friction (COF) and the normalized wear rate were determined. The improvement in hardness and wear resistance may be attributed to multiple factors, including high relative density, uniform SiC and GNP dispersion in the aluminum matrix, grain refinement through GNP pinning, as well as inhibition of dislocation movement by SiC NP. The nanocomposite sample containing 10 SiC and 0.5 GNP (by wt pct) yielded the maximum wear resistance at 10 N normal load. Microstructural characterization of the nanocomposite surfaces and wear debris was performed using scanning electron microscope (SEM) and transmission electron microscope (TEM). The synergistic effect of the GNP and SiC nanostructures accounts for superior wear resistance in the aluminum matrix nanocomposites.
NASA Technical Reports Server (NTRS)
Jegley, Dawn C.
1989-01-01
Results of a series of tests to determine the effects of adhesive interleaving and discontinuous plies (plies with end-to-end gaps) on the displacements, failure loads and failure modes of graphite-epoxy laminates subjected to transverse normal loads are presented. Adhesive interleaving can be used to contain local damage within a group of plies, i.e., to arrest crack propagation on the interlaminate level, and it can increase the amount of normal displacement the laminate can withstand before failure. However, the addition of adhesive interleaving to a laminate does not significantly increase its load carrying capability. A few discontinuous plies in a laminate can reduce the normal displacement and load at failure by 10 to 40 percent compared to a laminate with no discontinuous plies, but the presence of the ply discontinuities does not generally change the failure location or the failure mode of the laminate.
Hip ontogenesis: how evolution, genes, and load history shape hip morphotype and cartilotype.
Hogervorst, Tom; Eilander, Wouter; Fikkers, Joost T; Meulenbelt, Ingrid
2012-12-01
Developmental hip disorders (DHDs), eg, developmental dysplasia of the hip, slipped capitis femoris epiphysis, and femoroacetabular impingement, can be considered morphology variants of the normal hip. The femoroacetabular morphology of DHD is believed to induce osteoarthritis (OA) through local cumulative mechanical overload acting on genetically controlled patterning systems and subsequent damage of joint structures. However, it is unclear why hip morphology differs between individuals with seemingly comparable load histories and why certain hips with DHD progress to symptomatic OA whereas others do not. We asked (1) which mechanical factors influence growth and development of the proximal femur; and (2) which genes or genetic mechanisms are associated with hip ontogenesis. We performed a systematic literature review of mechanical and genetic factors of hip ontogeny. We focused on three fields that in recent years have advanced our knowledge of adult hip morphology: imaging, evolution, and genetics. WHERE ARE WE NOW?: Mechanical factors can be understood in view of human evolutionary peculiarities and may summate to load histories conducive to DHD. Genetic factors most likely act through multiple genes, each with modest effect sizes. Single genes that explain a DHD are therefore unlikely to be found. Apparently, the interplay between genes and load history not only determines hip morphotype, but also joint cartilage robustness ("cartilotype") and resistance to symptomatic OA. WHERE DO WE NEED TO GO?: We need therapies that can improve both morphotype and cartilotype. HOW DO WE GET THERE?: Better phenotyping, improving classification systems of hip morphology, and comparative population studies can be done with existing methods. Quantifying load histories likely requires new tools, but proof of principle of modifying morphotype in treatment of DDH and of cartilotype with exercise is available.
Raahave, Dennis
2015-03-01
The present studies explored whether faecal retention in the colon is a causative factor in functional bowel disease, appendicitis, and haemorrhoids. Faecal retention was characterized by colon transit time (CTT) after radio-opaque marker ingestion and estimation of faecal loading on abdominal radiographs at 48 h and 96 h. Specific hypotheses were tested in patients (n = 251 plus 281) and in healthy random controls (n = 44). A questionnaire was completed for each patient, covering abdominal and anorectal symptoms and without a priori grouping. Patients with functional bowel disorders, predominantly women, had a significantly increased CTT and faecal load compared to controls. The CTT was significantly and positively correlated with segmental and total faecal loading. The faecal load was equal at 48 h and 96 h, mirroring the presence of permanent faecal reservoirs. In these first clinical studies to correlate bowel symptoms with CTT and colon faecal loading, abdominal bloating was significantly correlated with faecal loading in the right colon, total faecal load, and CTT. Abdominal pain was significantly and positively correlated to distal faecal loading and significantly associated with bloating. A new phenomenon with a high faecal load and a normal CTT was observed in a subset of patients (n = 90), proving faecal retention as hidden constipation. The CTT and faecal load were significantly higher in the right-side compared to the left and distal segments. Within the control group of healthy persons, the right-sided faecal load was significantly greater than the left and distal load. The CTT and faecal load significantly positively correlated with a palpable mass in the left iliac fossa and meteorism. Cluster analysis revealed that CTT and faecal load positively correlated with a symptom factor consisting of bloating, proctalgia and infrequent defecation of solid faeces. On the other hand, CTT and faecal load negatively correlated with a symptom factor comprising frequent easy defecations, repetitiveness, and incompleteness with solid or liquid faeces. The majority of patients with a heavy faecal load but normal CTT had repetitive daily defecation, mostly with ease and with altering faecal consistence. Flue-like episodes co-existed in symptom factors with abdominal pain and meteorism, and these symptoms together with a palpable right iliac fossa mass and tenderness, and in other factors with seldom and difficult defecation, and with epigastric discomfort and halitosis. Patients with seldom and difficult defecation of solid faeces experienced abdominal pain significantly more often and presented a palpable mass in the right iliac fossa with tenderness and meteorism. The CTT was significantly prolonged and faecal load significantly increased. In patients with a normal CTT and increased faecal load, only patients with abdominal pain had a significant correlation between faecal loading and bloating. CTT and faecal load were shown for the first time to increase significantly with the number of colonic redundancies (colon length), which also resulted in significantly increased bloating and pain. Intervention with a bowel stimulation regimen combining a fibre-rich diet, fluid, physical activity, and a prokinetic drug was essential to proving that abdominal symptoms and defecation disorders are caused by faecal retention, with or without a prolonged CTT. The CTT was significantly reduced, as was faecal load. Bloating and pain were reduced significantly. The defecation became easy with solid faeces, towards one per day and with significant reductions in incompleteness and repetitiveness. Proctalgia and flue-like episodes were significantly reduced. The intervention significantly reduced the presence of a tender palpable mass in the right fossa and rectal constipation. In patients with a normal CTT but increased faecal load, the intervention did not significantly change the CTT or load, but bloating and pain were significantly reduced, just as defecation improved overall. The novel knowledge of faecal retention in the patients does not explain why faecal retention occurs. However, it may be inferred from the present results that a constipated or irritable bowel may belong to the same underlying disease dimension, where faecal retention is a common factor. Thus, measuring CTT and faecal load is suggested as a guide to a positive functional diagnosis of bowel disorders compared to the constellation of symptoms alone. Thirty-five patients underwent surgery after being refractory to the conservative treatment for constipation. They had a significantly prolonged CTT and heavy faecal loading, which was responsible for the aggravated abdominal and defaecatory symptoms. The operated patients presented with a redundant colon (dolichocolon) significantly more often. These patients also had an extremely high rate of previous appendectomy. Twenty-one patients underwent hemicolectomy, and 11 patients had a subtotal colectomy with an ileosigmoidal anastomosis; three patients received a stoma. However, some patients had to have the initial segmental colectomy converted to a final subtotal colectomy because of persisting symptoms. Six more subtotal colectomies have been performed and the leakage rate of all colectomies is then 4.9 % (one patient died). After a mean follow-up of 5 years, the vast majority of patients were without abdominal pain and bloating, having two to four defecations daily with control and their quality of life had increased considerably. A faecalith is often located in the appendix, the occlusion of which is responsible for many cases of acute appendicitis, which is infrequent in all except white populations. An effort to trace the origin of the faecalith to faecal retention in the colon was made in a case control study (56 patients and 44 random controls). The CTT was longer and faecal load greater in patients with appendicitis compared to controls, though the difference was not significant. Power calculations showed that more patients were needed to reach statistical significance for these parameters. The presence of a faecalith was most often associated with a gangrenous or perforated appendix. No significant differences were found between the CTT and faecal load of patients who had or did not have a faecalith. However, the right-sided faecal load was significantly higher than the left and distal load. Haemorrhoids are often a consequence of constipation and defaecatory disorders and were found in every second patient with functional bowel disorders. The present studies are the first Danish reports of a novel operation to cure this disease, stapled haemorrhoidopexy (n = 40 and 258 patients). The majority of patients had prolapsed haemorrhoids, and the durability of procedure was confirmed with a follow-up of up to 5 years, meaning a normal anus. The operation time was short, post-operative pain was low, and recovery was rapid. No incontinence was observed, and patient satisfaction was high and significantly correlated with the appearance of a normal anus without prolapse. The cumulative risk of re-operation was greatest in the first 2 years after the stapled haemorrhoidopexy. Patients with persisting haemorrhoidal prolapse had the procedure repeated with results as good as those obtained in the rest of the patients. It was shown in a statistical model that the preoperative severity of haemorrhoidal disease and the immediate postoperative result contributed significantly to predicting the outcome that is the durability of the operation. The most frequent post-operative complication was bleeding requiring surgical haemostasis. One serious complication occurred after an anastomotic leak from a highly placed anastomosis, resulting in retro rectal, retro- and intra-peritoneal, and mediastinal gas. The patient recovered after conservative treatment and without surgical intervention. The stapling technique now used has revolutionized the surgical treatment of prolapsing haemorrhoids. Finally, a common cause may be suspected for diseases constantly associated with one another. Epidemiological evidence has recognized that constipation, diverticulosis and IBS increase the risk of colon cancer (and adenomas), diseases exceedingly rare in communities exempt from appendicitis. Haemorrhoids are a colonic co-morbidity as well. Notably, the patients with a functional bowel disorder had a much higher rate of a previous appendectomy than the background population. In addition, the patients who had previously had an appendectomy had a significantly longer CTT compared to patients, who had not. The data points to the involvement of faecal retention in the origin of faecaliths and, thus, acute appendicitis. Faecal reservoirs were shown in the right and left colon segments in both patients and controls, which are the same areas bearing the highest incidences of adenomateous polyps and malignancies. Familial colorectal cancer occurred significantly more often in patients who had a higher faecal load than the controls. Four malignancies and 25 adenomas were identified. An increased faecal load in the colon with or without delayed transit will increase bacterial counts and create a chronic inflammation of the colonic mucosa, which is a risk factor for cancer onset. A functional bowel disorder is then likely to occur with gradually transition from a primary functional disease into specific organic diseases. A diet rich in fibre and regular physical activity have a therapeutic and preventive effect on colorectal diseases associated with faecal retention. A “common cause” was earlier proposed for constipation, colon diverticula, cancer, appendicitis, and haemorrhoids. The actual results of the present studies support this unifying theory for these diet-related diseases, in which the functional retention of faeces maybe the common cause.
46 CFR 112.30-3 - Normal source for emergency loads.
Code of Federal Regulations, 2012 CFR
2012-10-01
....30-3 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Emergency Systems Having an Automatically Connected Storage Battery as the Sole Emergency Power Source § 112.30-3 Normal source for emergency loads. (a) The normal source...
46 CFR 112.30-3 - Normal source for emergency loads.
Code of Federal Regulations, 2010 CFR
2010-10-01
....30-3 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Emergency Systems Having an Automatically Connected Storage Battery as the Sole Emergency Power Source § 112.30-3 Normal source for emergency loads. (a) The normal source...
46 CFR 112.30-3 - Normal source for emergency loads.
Code of Federal Regulations, 2013 CFR
2013-10-01
....30-3 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Emergency Systems Having an Automatically Connected Storage Battery as the Sole Emergency Power Source § 112.30-3 Normal source for emergency loads. (a) The normal source...
46 CFR 112.30-3 - Normal source for emergency loads.
Code of Federal Regulations, 2014 CFR
2014-10-01
....30-3 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Emergency Systems Having an Automatically Connected Storage Battery as the Sole Emergency Power Source § 112.30-3 Normal source for emergency loads. (a) The normal source...
46 CFR 112.30-3 - Normal source for emergency loads.
Code of Federal Regulations, 2011 CFR
2011-10-01
....30-3 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Emergency Systems Having an Automatically Connected Storage Battery as the Sole Emergency Power Source § 112.30-3 Normal source for emergency loads. (a) The normal source...
[Security at work in terms of risk factors (author's transl)].
Faverge, J M
1977-09-23
Accident epidemiology aims at determining those factors which are associated with an increased risk. Here accidents at work are considered in which any given situation involves: one or many individuals (I); one or many tasks (T); one or many machines or production tools (M); an environment (E). Eight factors are proposed for each of which one of the above components is dominant. Each factor is defined and examples are given. In addition, where applicable, the following are given: subfactors; references to studies which demonstrate the association between risk and factor; one or several possible action mechanisms; proposals enabling a quantitative evaluation to be made for statistical purposes; suggestions for prevention. The factors are: Individual disposition (I) or liability. Worker's inexperience (I). Stress (T) imposed on the worker. Recovery (T) (an exceptional task must be performed in order to regain normal work conditions). Catachresis (M) (a tool is used for an unusual purpose or a machine is required to exceed normal work load). Material wear (M) or damage. Interference (E) between partially independent processes. Insufficient information (E) concerning the state of the system.
Activation energy of the low-load NaCl transition from nanoindentation loading curves.
Kaupp, Gerd
2014-01-01
Access to activation energies E(a) of phase transitions is opened by unprecedented analyses of temperature dependent nanoindentation loading curves. It is based on kinks in linearized loading curves, with additional support by coincidence of kink and electrical conductivity of silicon loading curves. Physical properties of B1, B2, NaCl and further phases are discussed. The normalized low-load transition energy of NaCl (Wtrans/µN) increases with temperature and slightly decreases with load. Its semi-logarithmic plot versus T obtains activation energy E(a)/µN for calculation of the transition work for all interesting temperatures and pressures. Arrhenius-type activation energy (kJ/mol) is unavailable for indentation phase transitions. The E(a) per load normalization proves insensitive to creep-on-load, which excludes normalization to depth or volume for large temperature ranges. Such phase transition E(a)/µN is unprecedented material's property and will be of practical importance for the compatibility of composite materials under impact and further shearing interactions at elevated temperatures. © 2014 Wiley Periodicals, Inc.
Biomechanics of a Fixed–Center of Rotation Cervical Intervertebral Disc Prosthesis
Crawford, Neil R.; Baek, Seungwon; Sawa, Anna G.U.; Safavi-Abbasi, Sam; Sonntag, Volker K.H.; Duggal, Neil
2012-01-01
Background Past in vitro experiments studying artificial discs have focused on range of motion. It is also important to understand how artificial discs affect other biomechanical parameters, especially alterations to kinematics. The purpose of this in vitro investigation was to quantify how disc replacement with a ball-and-socket disc arthroplasty device (ProDisc-C; Synthes, West Chester, Pennsylvania) alters biomechanics of the spine relative to the normal condition (positive control) and simulated fusion (negative control). Methods Specimens were tested in multiple planes by use of pure moments under load control and again in displacement control during flexion-extension with a constant 70-N compressive follower load. Optical markers measured 3-dimensional vertebral motion, and a strain gauge array measured C4-5 facet loads. Results Range of motion and lax zone after disc replacement were not significantly different from normal values except during lateral bending, whereas plating significantly reduced motion in all loading modes (P < .002). Plating but not disc replacement shifted the location of the axis of rotation anteriorly relative to the intact condition (P < 0.01). Coupled axial rotation per degree of lateral bending was 25% ± 48% greater than normal after artificial disc replacement (P = .05) but 37% ± 38% less than normal after plating (P = .002). Coupled lateral bending per degree of axial rotation was 37% ± 21% less than normal after disc replacement (P < .001) and 41% ± 36% less than normal after plating (P = .001). Facet loads did not change significantly relative to normal after anterior plating or arthroplasty, except that facet loads were decreased during flexion in both conditions (P < .03). Conclusions In all parameters studied, deviations from normal biomechanics were less substantial after artificial disc placement than after anterior plating. PMID:25694869
DOE Office of Scientific and Technical Information (OSTI.GOV)
Umans, Stephen D; Nisley, Donald L; Melfi, Michael J
A line-start synchronous motor has a housing, a rotor shaft, and an output shaft. A soft-start coupling portion is operatively coupled to the output shaft and the rotor shaft. The soft-start coupling portion is configurable to enable the synchronous motor to obtain synchronous operation and to drive, at least near synchronous speed during normal steady state operation of the motor, a load having characteristics sufficient to prevent obtaining normal synchronous operation of the motor when the motor is operatively connected to the load in the absence of the soft-start coupling. The synchronous motor is sufficiently rated to obtain synchronous operationmore » and to drive, at least near synchronous speed during normal steady state operation of the motor, a load having characteristics sufficient to prevent obtaining normal synchronous operation of the motor when the motor is operatively connected to the load in the absence of the soft-start coupling.« less
Buckling analysis for anisotropic laminated plates under combined inplane loads
NASA Technical Reports Server (NTRS)
Viswanathan, A. V.; Tamekuni, M.; Baker, L. L.
1974-01-01
The buckling analysis presented considers rectangular flat or curved general laminates subjected to combined inplane normal and shear loads. Linear theory is used in the analysis. All prebuckling deformations and any initial imperfections are ignored. The analysis method can be readily extended to longitudinally stiffened structures subjected to combined inplane normal and shear loads.
46 CFR 46.15-10 - Subdivision load lines.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 45 and a “diamond” shall be substituted for the “disk”. No “fresh water” line will be marked. [CGFR... located in line with the highest subdivision load line. (f) One fresh water line shall be marked. When a subdivision and a normal load line are combined, the normal fresh water line only shall be used unless the...
Creep behaviour and creep mechanisms of normal and healing ligaments
NASA Astrophysics Data System (ADS)
Thornton, Gail Marilyn
Patients with knee ligament injuries often undergo ligament reconstructions to restore joint stability and, potentially, abate osteoarthritis. Careful literature review suggests that in 10% to 40% of these patients the graft tissue "stretches out". Some graft elongation is likely due to creep (increased elongation of tissue under repeated or sustained load). Quantifying creep behaviour and identifying creep mechanisms in both normal and healing ligaments is important for finding clinically relevant means to prevent creep. Ligament creep was accurately predicted using a novel yet simple structural model that incorporated both collagen fibre recruitment and fibre creep. Using the inverse stress relaxation function to model fibre creep in conjunction with fibre recruitment produced a superior prediction of ligament creep than that obtained from the inverse stress relaxation function alone. This implied mechanistic role of fibre recruitment during creep was supported using a new approach to quantify crimp patterns at stresses in the toe region (increasing stiffness) and linear region (constant stiffness) of the stress-strain curve. Ligament creep was relatively insensitive to increases in stress in the toe region; however, creep strain increased significantly when tested at the linear region stress. Concomitantly, fibre recruitment was evident at the toe region stresses; however, recruitment was limited at the linear region stress. Elevating the water content of normal ligament using phosphate buffered saline increased the creep response. Therefore, both water content and fibre recruitment are important mechanistic factors involved in creep of normal ligaments. Ligament scars had inferior creep behaviour compared to normal ligaments even after 14 weeks. In addition to inferior collagen properties affecting fibre recruitment and increased water content, increased glycosaminoglycan content and flaws in scar tissue were implicated as potential mechanisms of scar creep. Similarly, ligament autografts had persistently abnormal creep behaviour and creep recovery after 2 years likely due to infiltration by scar tissue. Short-term immobilization of autografts had long-term detrimental consequences perhaps due to re-injury of the graft at remobilization. Treatments that restore normal properties to these mechanistic factors in order to control creep would improve joint healing by restoring joint kinematics and maintaining normal joint loading.
Landing strategies of athletes with an asymptomatic patellar tendon abnormality.
Edwards, Suzi; Steele, Julie R; McGhee, Deirdre E; Beattie, Sue; Purdam, Craig; Cook, Jill L
2010-11-01
Risk factors associated with a clinical presentation of patellar tendinopathy are patellar tendon ultrasonographic abnormality (PTA) and excessive loading. It remains unknown whether characteristics of an athlete's landing technique contribute to this excessive patellar tendon loading. This study investigated whether asymptomatic athletes with and without PTA had different landing strategies and hypothesized that asymptomatic athletes with a PTA would create higher patellar tendon loading and a different lower-limb landing strategy compared with athletes with normal patellar tendons. Seven athletes with no previous history or clinical signs of patellar tendon injury with a PTA were matched to athletes with normal patellar tendons (controls). Participants performed five successful trials of a stop-jump task, which involved a simultaneous two-foot horizontal and then vertical landing. During each trial, the participants' ground reaction forces and lower-limb electromyographic data were recorded, the three-dimensional kinematics measured, and the peak patellar tendon force calculated by dividing the net knee joint moment by the patellar tendon moment arm. Significant between-group differences in landing technique were mostly observed during the horizontal landing phase. Participants with a PTA created similar patellar tendon loading to the controls, but with altered sequencing, by landing with significantly greater knee flexion and extending their hips while the controls flexed their hips as they landed, reflecting a different muscle recruitment order compared with the PTA group. The crucial part in the development of PTA and, in turn, patellar tendinopathy may not be the magnitude of the patellar tendon load but rather the loading patterns. This research provides clinicians with important landing assessment criteria against which to identify athletes at risk of developing patellar tendinopathy.
Tran, Jacqueline; Rice, Anthony J; Main, Luana C; Gastin, Paul B
2014-04-01
The systematic management of training requires accurate training load measurement. However, quantifying the training of elite Australian rowers is challenging because of (a) the multicenter, multistate structure of the national program; (b) the variety of training undertaken; and (c) the limitations of existing methods for quantifying the loads accumulated from varied training formats. Therefore, the purpose of this project was to develop a new measure for quantifying training loads in rowing (the T2minute method). Sport scientists and senior coaches at the National Rowing Center of Excellence collaborated to develop the measure, which incorporates training duration, intensity, and mode to quantify a single index of training load. To account for training at different intensities, the method uses standardized intensity zones (T zones) established at the Australian Institute of Sport. Each zone was assigned a weighting factor according to the curvilinear relationship between power output and blood lactate response. Each training mode was assigned a weighting factor based on whether coaches perceived it to be "harder" or "easier" than on-water rowing. A common measurement unit, the T2minute, was defined to normalize sessions in different modes to a single index of load; one T2minute is equivalent to 1 minute of on-water single scull rowing at T2 intensity (approximately 60-72% VO2max). The T2minute method was successfully implemented to support national training strategies in Australian high performance rowing. By incorporating duration, intensity, and mode, the T2minute method extends the concepts that underpin current load measures, providing 1 consistent system to quantify loads from varied training formats.
Structural design/margin assessment
NASA Technical Reports Server (NTRS)
Ryan, R. S.
1993-01-01
Determining structural design inputs and the structural margins following design completion is one of the major activities in space exploration. The end result is a statement of these margins as stability, safety factors on ultimate and yield stresses, fracture limits (fracture control), fatigue lifetime, reuse criteria, operational criteria and procedures, stability factors, deflections, clearance, handling criteria, etc. The process is normally called a load cycle and is time consuming, very complex, and involves much more than structures. The key to successful structural design is the proper implementation of the process. It depends on many factors: leadership and management of the process, adequate analysis and testing tools, data basing, communications, people skills, and training. This process and the various factors involved are discussed.
Nondestructive Examination for Nuclear Power Plant Cable Aging Management Programs
DOE Office of Scientific and Technical Information (OSTI.GOV)
Glass, Samuel W.; Fifield, Leonard S.
2016-01-01
Degradation of the cable jacket, electrical insulation, and other cable components of installed cables within nuclear power plants (NPPs) is known to occur as a function of age, temperature, radiation, and other environmental factors. System tests verify cable function under normal loads; however, the concern is over cable performance under exceptional loads associated with design-basis events (DBEs). The cable’s ability to perform safely over the initial 40 year planned and licensed life has generally been demonstrated and there have been very few age-related cable failures. With greater than 1000 km of power, control, instrumentation, and other cables typically found inmore » an NPP, replacing all the cables would be a severe cost burden. Justification for life extension to 60 and 80 years requires a cable aging management program (AMP) to justify cable performance under normal operation as well as accident conditions. This paper addresses various NDE technologies that constitute the essence of an acceptable aging management program.« less
NASA Astrophysics Data System (ADS)
Nikulin, S.; Nikitin, A.; Belov, V.; Rozhnov, A.; Turilina, V.; Anikeenko, V.; Khatkevich, V.
2017-07-01
The crack resistances as well as fracture behavior of 20GL steel quenched with a fast-moving water stream and having gradient microstructure and strength are analyzed. Crack resistance tests with quenched and normalized flat rectangular specimens having different cut lengths loaded by three-point bending with acoustic emission measurements have been performed. The critical J-integral has been used as the crack resistance parameter of the material. Quenching with a fast moving water stream leads to gradient (along a specimen wall thickness) strengthening of steel due to highly refined gradient microstructure formation of the troostomartensite type. Quenching with a fast-moving water stream increases crack resistance Jc , of 20GL steel by a factor of ∼ 1.5. The fracture accrues gradually with the load in the normalized specimens while the initiated crack is hindered in the variable ductility layer and further arrested in the more ductile core in the quenched specimens.
Load estimation from photoelastic fringe patterns under combined normal and shear forces
NASA Astrophysics Data System (ADS)
Dubey, V. N.; Grewal, G. S.
2009-08-01
Recently there has been some spurt of interests to use photoelastic materials for sensing applications. This has been successfully applied for designing a number of signal-based sensors, however, there have been limited efforts to design image-based sensors on photoelasticity which can have wider applications in term of actual loading and visualisation. The main difficulty in achieving this is the infinite loading conditions that may generate same image on the material surface. This, however, can be useful for known loading situations as this can provide dynamic and actual conditions of loading in real time. This is particularly useful for separating components of forces in and out of the loading plane. One such application is the separation of normal and shear forces acting on the plantar surface of foot of diabetic patients for predicting ulceration. In our earlier work we have used neural networks to extract normal force information from the fringe patterns using image intensity. This paper considers geometric and various other statistical parameters in addition to the image intensity to extract normal as well as shear force information from the fringe pattern in a controlled experimental environment. The results of neural network output with the above parameters and their combinations are compared and discussed. The aim is to generalise the technique for a range of loading conditions that can be exploited for whole-field load visualisation and sensing applications in biomedical field.
Pathophysiology of osteoporosis: new mechanistic insights.
Armas, Laura A G; Recker, Robert R
2012-09-01
Understanding of the pathophysiology of osteoporosis has evolved to include compromised bone strength and skeletal fragility caused by several factors: (1) defects in microarchitecture of trabeculae, (2) defective intrinsic material properties of bone tissue, (3) defective repair of microdamage from normal daily activities, and (4) excessive bone remodeling rates. These factors occur in the context of age-related bone loss. Clinical studies of estrogen deprivation, antiresorptives, mechanical loading, and disuse have helped further knowledge of the factors affecting bone quality and the mechanisms that underlie them. This progress has led to several new drug targets in the treatment of osteoporosis. Copyright © 2012 Elsevier Inc. All rights reserved.
A general factor of death distress in seven clinical and non-clinical groups.
Abdel-Khalek, Ahmed M
2004-11-01
The Arabic Scale of Death anxiety (ASDA), the Death Depression Scale (DDS), and the Death Obsession Scale (DOS) were administered, individually, to 7 groups (n = 765) of Egyptian normal participants (non-clinical), anxiety disorder patients, patients suffering from schizophrenia (males and females), and addicts (males only). They were generally matched as groups according to age, occupation, and education. The intercorrelations between the 3 scales in all 7 groups were significant and positive. A general high-loaded factor of death distress was extracted in all 7 groups. It was the only salient factor, accounting for 50-70% of the common variance.
Probabilistic liquefaction triggering based on the cone penetration test
Moss, R.E.S.; Seed, R.B.; Kayen, R.E.; Stewart, J.P.; Tokimatsu, K.
2005-01-01
Performance-based earthquake engineering requires a probabilistic treatment of potential failure modes in order to accurately quantify the overall stability of the system. This paper is a summary of the application portions of the probabilistic liquefaction triggering correlations proposed recently proposed by Moss and co-workers. To enable probabilistic treatment of liquefaction triggering, the variables comprising the seismic load and the liquefaction resistance were treated as inherently uncertain. Supporting data from an extensive Cone Penetration Test (CPT)-based liquefaction case history database were used to develop a probabilistic correlation. The methods used to measure the uncertainty of the load and resistance variables, how the interactions of these variables were treated using Bayesian updating, and how reliability analysis was applied to produce curves of equal probability of liquefaction are presented. The normalization for effective overburden stress, the magnitude correlated duration weighting factor, and the non-linear shear mass participation factor used are also discussed.
Eccentric exercise: acute and chronic effects on healthy and diseased tendons.
Kjaer, Michael; Heinemeier, Katja M
2014-06-01
Eccentric exercise can influence tendon mechanical properties and matrix protein synthesis. mRNA for collagen and regulatory factors thereof are upregulated in animal tendons, independent of muscular contraction type, supporting the view that tendon, compared with skeletal muscle, is less sensitive to differences in type and/or amount of mechanical stimulus with regard to expression of collagen, regulatory factors for collagen, and cross-link regulators. In overused (tendinopathic) human tendon, eccentric exercise training has a beneficial effect, but the mechanism by which this is elicited is unknown, and slow concentric loading appears to have similar beneficial effects. It may be that tendinopathic regions, as long as they are subjected to a certain magnitude of load at a slow speed, independent of whether this is eccentric or concentric in nature, can reestablish their normal tendon fibril alignment and cell morphology. Copyright © 2014 the American Physiological Society.
Interference-Fit Life Factors for Ball Bearings
NASA Technical Reports Server (NTRS)
Oswald, Fred B.; Zaretsky, Erwin V.; Poplawski, Joseph V.
2010-01-01
The effect of hoop stresses on the rolling-element fatigue life of angular-contact and deep-groove ball bearings was determined for common inner-ring interference fits at the ABEC-5 tolerance level. The analysis was applied to over 1150 bearing configurations and load cases. Hoop stresses were superimposed on the Hertzian principal stresses created by the applied bearing load to calculate the inner-race maximum shearing stress. The resulting fatigue life of the bearing was recalculated through a series of equations. The reduction in the fatigue life is presented as life factors that are applied to the unfactored bearing life. The life factors found in this study ranged from 1.00 (no life reduction)--where there was no net interface pressure--to a worst case of 0.38 (a 62-percent life reduction). For a given interference fit, the reduction in life is different for angular-contact and deep-groove ball bearings. Interference fits also affect the maximum Hertz stress-life relation. Experimental data of Czyzewski, showing the effect of interference fit on rolling-element fatigue life, were reanalyzed to determine the shear stress-life exponent. The Czyzewski data shear stress-life exponent c equals 8.77, compared with the assumed value of 9. Results are presented as tables and charts of life factors for angular-contact and deep-groove ball bearings with light, normal, and heavy loads and interference fits ranging from extremely light to extremely heavy.
Is the central nervous system a reservoir of HIV-1?
Gray, Lachlan R.; Roche, Michael; Flynn, Jacqueline K.; Wesselingh, Steve L.; Gorry, Paul R.; Churchill, Melissa J.
2014-01-01
Purpose of the review To summarize the evidence in the literature that supports the CNS as a viral reservoir for HIV-1 and to prioritise future research efforts. Recent findings HIV-1 DNA has been detected in brain tissue of patients with undetectable viral load or neurocognitive disorders, and is associated with long-lived cells such as astrocytes and microglia. In neurocognitively normal patients, HIV-1 can be found at high frequency in these cells (4% of astrocytes and 20% of macrophages). CNS cells have unique molecular mechanisms to suppress viral replication and induce latency, which include increased expression of dominant negative transcription factors and suppressive epigenetic factors. There is also evidence of continued inflammation in patients lacking a CNS viral load, suggesting the production and activity of viral neurotoxins (for example Tat). Summary Together, these findings provide evidence that the CNS can potentially act as a viral reservoir of HIV-1. However, the majority of these studies were performed in historical cohorts (absence of cART or presence of viral load) which do not reflect modern day patients (cART-treated and undetectable viral load). Future studies will need to examine patient samples with these characteristics to conclusively determine if the CNS represents a relevant and important viral reservoir. PMID:25203642
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, Tianlei; Gao, Yanfei; Bei, Hongbin
2011-01-01
Instrumented nanoindentation techniques have been widely used to characterize the small-scale mechanical behavior of materials. The elastic-plastic transition during nanoindentation is often indicated by a sudden displacement burst (pop-in) in the measured load-displacement curve. In defect-free single crystals, the pop-in is believed to be the result of homogeneous dislocation nucleation because the maximum shear stress corresponding to the pop-in load approaches the theoretical strength of the materials and because the statistical distribution of pop-in stresses is consistent with what is expected for a thermally activated process of homogeneous dislocation nucleation. This paper investigates whether this process is affected by crystallographymore » and stress components other than the resolved shear stress. A Stroh formalism coupled with the two-dimensional Fourier transformation is used to derive the analytical stress fields in elastically anisotropic solids under Hertzian contact, which allows the determination of an indentation Schmid factor, namely, the ratio of maximum resolved shear stress to the maximum contact pressure. Nanoindentation tests were conducted on B2-structured NiAl single crystals with different surface normal directions. This material was chosen because it deforms at room temperature by {110}<001> slip and thus avoids the complexity of partial dislocation nucleation. Good agreement is obtained between the experimental data and the theoretically predicted orientation dependence of pop-in loads based on the indentation Schmid factor. Pop-in load is lowest for indentation directions close to <111> and highest for those close to <001>. In nanoindentation, since the stress component normal to the slip plane is typically comparable in magnitude to the resolved shear stress, we find that the pressure sensitivity of homogeneous dislocation nucleation cannot be determined from pop-in tests. Our statistical measurements generally confirm the thermal activation model of homogeneous dislocation nucleation. That is, the extracted dependence of activation energy on resolved shear stress is almost the same for all the indentation directions considered in this study, except for those close to <001>. Because very high pop-in loads are measured for orientations close to <001>, which implies a large contact area at pop-in, there is a higher probability of activating pre-existing dislocations in these orientations, which may explain the discrepancy near <001>.« less
Combined mode I stress intensity factors of slanted cracks
NASA Astrophysics Data System (ADS)
Ismail, A. E.; Rahman, M. Q. Abdul; Ghazali, M. Z. Mohd; Zulafif Rahim, M.; Rasidi Ibrahim, M.; Fahrul Hassan, Mohd; Nor, Nik Hisyamudin Muhd; Ariffin, A. M. T.; Zaini Yunos, Muhamad
2017-08-01
The solutions of stress intensity factors (SIFs) for slanted cracks in plain strain plate are hard to find in open literature. There are some previous solutions of SIFs available, however the studies are not completed except for the case of plain stress. The slanted cracks are modelled numerically using ANSYS finite element program. There are ten slanted angles and seven relative crack depths are used and the plate contains cracks which is assumed to fulfil the plain strain condition. The plate is then stressed under tension and bending loading and the SIFs are determined according to the displacement extrapolation method. Based on the numerical analysis, both slanted angles and relative crack length, a/L played an important role in determining the modes I and II SIFs. As expected the SIFs increased when a/L is increased. Under tension force, the introduction of slanted angles increased the SIFs. Further increment of angles reduced the SIFs however they are still higher than the SIFs obtained using normal cracks. Under bending moment, the present of slanted angles are significantly reduced the SIFs compared with the normal cracks. Under similar loading, mode II SIFs increased as function of a/L and slanted angles where increasing such parameters increasing the mode II SIFs.
NASA Astrophysics Data System (ADS)
Shi, Jing; Gong, Zhenbin; Wang, Yongfu; Gao, Kaixiong; Zhang, Junyan
2017-11-01
In this study, tribological properties of hydrogenated and hydrogen free diamond-like carbon films at various relative humidity (RH) were investigated to understand the friction mechanism in the presence of water molecules. At normal load of 2N, DLC-H film's friction coefficient was 0.06 at RH14% while DLC film's friction coefficient was 0.19 at RH17%. With the increase of RH, their friction coefficient converged to about 0.15. This character remained unaltered when the normal load was 5N. Results show that low friction of DLC-H film at low RH was attributed to the low shear force aroused by graphitic tribofilm at wear care center. However, the high friction of DLC film was mainly endowed by the high adhesive force aroused by σ dangling bonds. At high RH, solid-to-solid contact was isolated by water molecules confined between the counterfaces, where capillary was a dominant factor for friction. In addition to the capillary force, the absence of tribofilm was also accountable. These two factors lead to the level off of friction coefficient for DLC-H and DLC films. Moreover, for both DLC-H and DLC films, tribo-oxidization was proved to be closely related to wear rate with the assist of H2O molecules during sliding.
McKenzie, Donald J.; Irwin, G.A.
1983-01-01
Runoff from a heavily-traveled, 1.43-acre bridge section of Interstate-95 in Miami, Florida, was comprehensively monitored for both quality and quantity during five selected storms between November 1979 and May 1981. For most water-quality parameters, 6 to 11 samples were collected during each of the 5 runoff events. Concentrations of most parameters in the runoff were quite variable both during individual storm events and among the five storm events; however, the ranges in parameter concentration were about the same magnitude report for numerous other highway and urban drainages. Data were normalized to estimate the average, discharge-weighted parameter loads per storm per acre of bridge surface and results suggested that the most significant factor influencing stormwater loads was parameter concentration. Rainfall intensity and runoff volume, however, influenced rates of loading. The total number of antecedent dry days and traffic volume did not appear to be conspicously related to either runoff concentrations or loads. (USGS)
Optimization of doxorubicin loading for superabsorbent polymer microspheres: in vitro analysis.
Liu, David M; Kos, Sebastian; Buczkowski, Andrzej; Kee, Stephen; Munk, Peter L; Klass, Darren; Wasan, Ellen
2012-04-01
This study was designed to establish the ability of super-absorbent polymer microspheres (SAP) to actively uptake doxorubicin and to establish the proof of principle of SAP's ability to phase transfer doxorubicin onto the polymer matrix and to elute into buffer with a loading method that optimizes physical handling and elution characteristics. Phase I: 50-100 μm SAP subject to various prehydration methods (normal saline 10 cc, hypertonic saline 4 cc, iodinated contrast 10 cc) or left in their dry state, and combined with 50 mg of clinical grade lyophilized doxorubicin reconstituted with various methods (normal saline 10 cc and 25 cc, sterile water 4 cc, iodinated contrast 5 cc) were placed in buffer and assessed based on loading, handling, and elution utilizing high-performance liquid chromatography (HPLC). Phase II: top two performing methods were subject to loading of doxorubicin (50, 75, 100 mg) in a single bolus (group A) or as a serial loading method (group B) followed by measurement of loading vs. time and elution vs. time. Phase I revealed the most effective loading mechanisms and easiest handling to be dry (group A) vs. normal saline prehydrated (group B) SAP with normal saline reconstituted doxorubicin (10 mg/mL) with loading efficiencies of 83.1% and 88.4%. Phase II results revealed unstable behavior of SAP with 100 mg of doxorubicin and similar loading/elution profiles of dry and prehydrated SAP, with superior handling characteristics of group B SAP at 50 and 75 mg. SAP demonstrates the ability to load and bulk phase transfer doxorubicin at 50 and 75 mg with ease of handling and optimal efficiency through dry loading of SAP.
Optimization of Doxorubicin Loading for Superabsorbent Polymer Microspheres: in vitro Analysis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, David M., E-mail: dave.liu@vch.ca; Kos, Sebastian; Buczkowski, Andrzej
2012-04-15
Purpose: This study was designed to establish the ability of super-absorbent polymer microspheres (SAP) to actively uptake doxorubicin and to establish the proof of principle of SAP's ability to phase transfer doxorubicin onto the polymer matrix and to elute into buffer with a loading method that optimizes physical handling and elution characteristics. Methods: Phase I: 50-100 {mu}m SAP subject to various prehydration methods (normal saline 10 cc, hypertonic saline 4 cc, iodinated contrast 10 cc) or left in their dry state, and combined with 50 mg of clinical grade lyophilized doxorubicin reconstituted with various methods (normal saline 10 cc andmore » 25 cc, sterile water 4 cc, iodinated contrast 5 cc) were placed in buffer and assessed based on loading, handling, and elution utilizing high-performance liquid chromatography (HPLC). Phase II: top two performing methods were subject to loading of doxorubicin (50, 75, 100 mg) in a single bolus (group A) or as a serial loading method (group B) followed by measurement of loading vs. time and elution vs. time. Results: Phase I revealed the most effective loading mechanisms and easiest handling to be dry (group A) vs. normal saline prehydrated (group B) SAP with normal saline reconstituted doxorubicin (10 mg/mL) with loading efficiencies of 83.1% and 88.4%. Phase II results revealed unstable behavior of SAP with 100 mg of doxorubicin and similar loading/elution profiles of dry and prehydrated SAP, with superior handling characteristics of group B SAP at 50 and 75 mg. Conclusions: SAP demonstrates the ability to load and bulk phase transfer doxorubicin at 50 and 75 mg with ease of handling and optimal efficiency through dry loading of SAP.« less
Study of the kinematic and load sharing properties of wormgearing with non-symmetric tooth profiles
NASA Technical Reports Server (NTRS)
Sun, D. C.; Yuan, Qin
1995-01-01
The geometry of non-symmetric tooth profiles, i.e. tooth profiles with different pressure angles on the two sides of the tooth, is studied. A feasible non-symmetric tooth profile for application in helicopter transmissions is laid out as the best compromise among several conflicting factors. The non-symmetric tooth profile is then compared with the symmetric tooth profile studied previously. Based on the detailed comparisons it is concluded that the use of the non-symmetric tooth profile would severely limit the face width of the worm, consequently reduce the number of meshing teeth and cause much higher normal load on the individual gear teeth.
NASA Astrophysics Data System (ADS)
Zhao, Xiang-Feng; Shang, De-Guang; Sun, Yu-Juan; Song, Ming-Liang; Wang, Xiao-Wei
2018-01-01
The maximum shear strain and the normal strain excursion on the critical plane are regarded as the primary parameters of the crack driving force to establish a new short crack model in this paper. An equivalent strain-based intensity factor is proposed to correlate the short crack growth rate under multiaxial loading. According to the short crack model, a new method is proposed for multiaxial fatigue life prediction based on crack growth analysis. It is demonstrated that the method can be used under proportional and non-proportional loadings. The predicted results showed a good agreement with experimental lives in both high-cycle and low-cycle regions.
Preliminary Results of Stability and Control Investigation of the Bell X-5 Research Airplane
NASA Technical Reports Server (NTRS)
Finch, Thomas W; Briggs, Donald W
1953-01-01
During the acceptance tests of the Bell X-5 airplane, measurements of the static stability and control characteristics and horizontal-tail loads were obtained by the NACA High-Speed Flight Research Station. The results of the stability and control measurements are presented in this paper. A change in sweep angle between 20 deg and 59 deg had a minor effect on the longitudinal trim, with a maximum change of about 2.5 deg in elevator deflection being required at a Mach number near 0.85; however, sweeping the wings produced a total stick-force change of about 40 pounds. At low Mach numbers there was a rapid increase in stability at high normal-force coefficients for both 20 0 and 1100 sweepback, whereas a condition of neutral stability existed for 58 0 sweepback at high normal-force coefficients. At Mach numbers near 0.8 there was an instability at normal-force coefficients above 0.5 for all sweep angles tested. In the low normal-force-coefficient range a high degree of stability resulted in high stick forces which limited the maximum load factors attainable in the demonstration flights to values under 5g for all sweep angles at a Mach number near 0.8 and an altitude of 12,000 feet. The aileron effectiveness at 200 sweepback was found to be low over the Mach number range tested.
Li, Wanzhong; Xu, Yingqiang; He, Huiming; Zhao, Haidan; Sun, Jian; Hou, Yue
2015-01-01
Clinical cases show that zirconia restoration could happen fracture by accident under overloading after using a period of time. The purpose of this study is to research mechanical behavior and predict lifetime of dental zirconia ceramics under cyclic normal contact loading with experiments. Cyclic normal contact loading test and three point bending test are carried on specimens made of two brands of dental zirconia ceramic to obtain flexure strength and damage degree after different number of loading cycles. By means of damage mechanics model, damage degree under different number of contact loading cycles are calculated according to flexure strength, and verified by SEM photographs of cross section morphology of zirconia ceramics specimen phenomenologically. Relation curve of damage degree and number of cycles is fitted by polynomial fitting, then the number of loading cycles can be concluded when the specimen is complete damage. Strength degradation of two brands dental zirconia ceramics are researched in vitro, and prediction method of contact fatigue lifetime is established.
Mymryk, J S; Berard, D; Hager, G L; Archer, T K
1995-01-01
We have stably introduced a reporter gene under the control of the mouse mammary tumor virus (MMTV) long terminal repeat (LTR) into human T47D breast cancer cells to study the action of the progesterone receptor (PR) on transcription from a chromatin template. Unexpectedly, the chromatin organization of the MMTV LTR in these human breast cancer cells differed markedly from what we have observed previously. The region adjacent to the transcription start site (-221 to -75) was found to be constitutively hypersensitive to restriction enzyme cleavage in the absence of hormone. This region is normally encompassed within the second nucleosome of a phased array of six nucleosomes that is assembled when the MMTV LTR is stably maintained in mouse cells. Characteristically, in these rodent cells, the identical DNA sequences show increased restriction enzyme cleavage only in the presence of glucocorticoid. The increased access of restriction enzymes observed in the human PR+ cells was not observed in adjacent nucleosomes and was unaffected by treatment with the progesterone antagonist RU486. In addition, exonuclease III-dependent stops corresponding to the binding sites for nuclear factor 1 and the PR were observed before and after hormone treatment. These results indicate that MMTV chromatin replicated in these cells is organized into a constitutively open architecture and that this open chromatin state is accompanied by hormone-independent loading of a transcription factor complex that is normally excluded from uninduced chromatin. PMID:7799933
Mymryk, J S; Berard, D; Hager, G L; Archer, T K
1995-01-01
We have stably introduced a reporter gene under the control of the mouse mammary tumor virus (MMTV) long terminal repeat (LTR) into human T47D breast cancer cells to study the action of the progesterone receptor (PR) on transcription from a chromatin template. Unexpectedly, the chromatin organization of the MMTV LTR in these human breast cancer cells differed markedly from what we have observed previously. The region adjacent to the transcription start site (-221 to -75) was found to be constitutively hypersensitive to restriction enzyme cleavage in the absence of hormone. This region is normally encompassed within the second nucleosome of a phased array of six nucleosomes that is assembled when the MMTV LTR is stably maintained in mouse cells. Characteristically, in these rodent cells, the identical DNA sequences show increased restriction enzyme cleavage only in the presence of glucocorticoid. The increased access of restriction enzymes observed in the human PR+ cells was not observed in adjacent nucleosomes and was unaffected by treatment with the progesterone antagonist RU486. In addition, exonuclease III-dependent stops corresponding to the binding sites for nuclear factor 1 and the PR were observed before and after hormone treatment. These results indicate that MMTV chromatin replicated in these cells is organized into a constitutively open architecture and that this open chromatin state is accompanied by hormone-independent loading of a transcription factor complex that is normally excluded from uninduced chromatin.
NASA Technical Reports Server (NTRS)
Ghosh, M. K.; Hamrock, B. J.; Brewe, D. E.
1986-01-01
The effect of inlet starvation on the hydrodynamic lubrication of lightly loaded rigid nonconformal contacts in combined rolling and normal motion is determined through a numerical solution of the Reynolds' equation for an isoviscous, incompressible lubricant. Starvation is effected by systematically reducing the fluid inlet level. The pressures are taken to be ambient at the inlet meniscus boundary and Reynolds' boundary condition is applied for film rupture in the exit region. Results are presented for the dynamic performance of the starved contacts in combined rolling and normal motion for both normal approach and separation. During normal approach the dynamic load ratio (i.e. ratio of dynamic to steady state load capacity) increases considerably with increase in the inlet starvation. The effect of starvation on the dynamic peak pressure ratio is relatively small. Further, it has been observed that with increasing starvation, film thickness effects become significant in the dynamic behavior of the nonconformal contacts. For significantly starved contacts the dynamic load ratio increases with increase in film thickness during normal approach and a similar reduction is observed during separation. A similar effect is noted for the dynamic peak pressure ratio.
Hua, Xijin; Li, Junyan; Jin, Zhongmin; Fisher, John
2016-06-01
The occurrence of edge loading in hip joint replacement has been associated with many factors such as prosthetic design, component malposition and activities of daily living. The present study aimed to quantify the occurrence of edge loading/contact at the articulating surface and to evaluate the effect of cup angles and edge loading on the contact mechanics of a modular metal-on-polyethylene (MoP) total hip replacement (THR) during different daily activities. A three-dimensional finite element model was developed based on a modular MoP bearing system. Different cup inclination and anteversion angles were modelled and six daily activities were considered. The results showed that edge loading was predicted during normal walking, ascending and descending stairs activities under steep cup inclination conditions (≥55°) while no edge loading was observed during standing up, sitting down and knee bending activities. The duration of edge loading increased with increased cup inclination angles and was affected by the cup anteversion angles. Edge loading caused elevated contact pressure at the articulating surface and substantially increased equivalent plastic strain of the polyethylene liner. The present study suggested that correct positioning the component to avoid edge loading that may occur during daily activities is important for MoP THR in clinical practice. Copyright © 2016. Published by Elsevier Ltd.
Córdoba, J; Olaso, V; Molina, J M; López Viedma, B; Argüello, L; Ortiz, V; Esteban, R J; Garijo, R; Pastor, M; Gobernado, M
2000-01-01
Two standardized techniques, Quantiplex (bDNA-2.0) and Amplicor Monitor have been evaluated for the quantification of virus load of HCV with these objectives: a) determinate the relationship between virus load and genotype, and b) evaluate the virus load in serial serum samples and in patients with normal or slightly increased liver enzymes in an area with a high prevalence of genotype 1. A significant correlation of 0.7 (p < 0.0001) in virus load has been observed by both methods, but the virus load is smaller by Monitor than by Quantiplex and does not depend on genotype. The relationship Monitor/Quantiplex is smaller in patients with non-1 genotype than in patients with genotype 1a (p = 0.01) and 1b (p = 0.005). Virus characteristics are similar in patients with normal or slightly increased enzymes than in patients with high enzymes. Virus load by both methods is not related to the age, sex, know duration of the infection, transmission manner of the infection neither to the histologic activity index. The virus load not depends on genotype. The determination of virus load in a single serum sample adequately reflects the virus load are in several serum samples in patients with chronic HCV infection. The genotype and the virus load are similar in patients with normal enzymes than in patients with high enzymes.
Beus, Michael J.; McCoy, William G.
1998-01-01
Apparatus for sensing the magnitude of a load on a cable as the cable is employed to support the load includes a beam structure clamped to the cable so that a length of the cable lies along the beam structure. A spacer associated with the beam structure forces a slight curvature in a portion of the length of cable under a cable "no-load" condition so that the portion of the length of cable is spaced from the beam structure to define a cable curved portion. A strain gauge circuit including strain gauges is secured to the beam structure by welding. As the cable is employed to support a load the load causes the cable curved portion to exert a force normal to the cable through the spacer and on the beam structure to deform the beam structure as the cable curved portion attempts to straighten under the load. As this deformation takes place, the resistance of the strain gauges is set to a value proportional to the magnitude of the normal strain on the beam structure during such deformation. The magnitude of the normal strain is manipulated in a control device to generate a value equal to the magnitude or weight of the load supported by the cable.
Static Prehension of a Horizontally Oriented Object in Three Dimensions
Wu, Yen-Hsun; Zatsiorsky, Vladimir M.; Latash, Mark L.
2011-01-01
We studied static prehension of a horizontally oriented object. Specific hypotheses were explored addressing such issues as the sharing patterns of the total moment of force across the digits, presence of mechanically unnecessary digit forces, and trade-off between multi-digit synergies at the two levels of the assumed control hierarchy. Within the assumed hierarchy, at the upper level, the task is shared between the thumb and virtual finger (an imagined finger producing a wrench equal to the sum of the wrenches of individual fingers). At the lower level, action of the virtual finger is shared among the four actual fingers. The subjects held statically a horizontally oriented handle instrumented with six-component force/torque sensors with different loads and torques acting about the long axis of the handle. The thumb acted from above while the four fingers supported the weight of the object. When the external torque was zero, the thumb produced mechanically unnecessary force of about 2.8 N, which did not depend on the external load magnitude. When the external torque was not zero, tangential forces produced over 80% of the total moment of force. The normal forces by the middle and ring fingers produced consistent moments against the external torque, while the normal forces of the index and little fingers did not. Force and moment variables at both hierarchical levels were stabilized by co-varied across trials adjustments of forces/moments produced by individual digits with the exception of the normal force analyzed at the lower level of the hierarchy. There was a trade-off between synergy indices computed at the two levels of the hierarchy for the three components of the total force vector, but not for the moment of force components. Overall, the results have shown that task mechanics are only one factor that defines forces produced by individual digits. Other factors, such as loading sensory receptors may lead to mechanically unnecessary forces. There seems to be no single rule (for example, ensuring similar safety margin values) that would describe sharing of the normal and tangential forces and be valid across tasks. Fingers that are traditionally viewed as less accurate (e.g., the ring finger) may perform more consistently in certain tasks. The observations of the trade-off between the synergy indices computed at two levels for the force variables but not for the moment of force variables suggest that the degree of redundancy (the number of excessive elemental variables) at the higher level is an important factor. PMID:22071684
Polypyrrole electrodes doped with sulfanilic acid azochromotrop for electrochemical supercapacitors
NASA Astrophysics Data System (ADS)
Chen, S.; Zhitomirsky, I.
2013-12-01
In this work we demonstrate the feasibility of deposition of polypyrrole (PPy) films by electropolymerization on stainless steel substrates and fabrication of PPy powders by chemical polymerization using sulfanilic acid azochromotrop (SPADNS) as a new anionic dopant. The problem of low adhesion of PPy films to stainless steel substrates is addressed by the use of SPADNS, which exhibits chelating properties, promoting film formation. The use of fine particles, prepared by the chemical polymerization method, allows impregnation of Ni foams and fabrication of porous electrodes with high materials loading for electrochemical supercapacitors (ES). PPy films and Ni foam based PPy electrodes show capacitive behaviour in Na2SO4 electrolyte. The electron microscopy studies, impedance spectroscopy data and analysis of the SPADNS structure provide an insight into the factors, controlling capacitive behaviour. The Ni foam based electrodes offer advantages of improved capacitive behaviour at high materials loadings and good cycling stability. The area normalized and volume normalized specific capacitances are as high as 5.43 F cm-2 and 93.6 F cm-3, respectively, for materials loading of 35.4 mg cm-2. The capacitance retention of Ni foam based electrodes is 91.5% after 1000 cycles. The Ni foam based PPy electrodes are promising for application in ES.
Guided waves by axisymmetric and non-axisymmetric surface loading on hollow cylinders
Shin; Rose
1999-06-01
Guided waves generated by axisymmetric and non-axisymmetric surface loading on a hollow cylinder are studied. For the theoretical analysis of the superposed guided waves, a normal mode concept is employed. The amplitude factors of individual guided wave modes are studied with respect to varying surface pressure loading profiles. Both theoretical and experimental focus is given to the guided waves generated by both axisymmetric and non-axisymmetric excitation. For the experiments, a comb transducer and high power tone burst function generator system are used on a sample Inconel tube. Surface loading conditions, such as circumferential loading angles and axial loading lengths, are used with the frequency and phase velocity to control the axisymmetric and non-axisymmetric mode excitations. The experimental study demonstrates the use of a practical non-axisymmetric partial loading technique in generating axisymmetric modes, particularly useful in the inspection of tubing and piping with limited circumferential access. From both theoretical and experimental studies, it also could be said that the amount of flexural modes reflected from a defect contains information on the reflector's circumferential angle, as well as potentially other classification and sizing feature information. The axisymmetric and non-axisymmetric guided wave modes should both be carefully considered for improvement of the overall analysis of guided waves generated in hollow cylinders.
Thiros, Susan A.
2017-03-23
The U.S. Geological Survey (USGS), in cooperation with the Colorado River Basin Salinity Control Forum, studied trends in dissolved-solids loads at selected sites in and near the Uinta Basin, Utah. The Uinta Basin study area includes the Duchesne River Basin and the Middle Green River Basin in Utah from below Flaming Gorge Reservoir to the town of Green River.Annual dissolved-solids loads for water years (WY) 1989 through 2013 were estimated for 16 gaging stations in the study area using streamflow and water-quality data from the USGS National Water Information System database. Eight gaging stations that monitored catchments with limited or no agricultural land use (natural subbasins) were used to assess loads from natural sources. Four gaging stations that monitored catchments with agricultural land in the Duchesne River Basin were used to assess loads from agricultural sources. Four other gaging stations were included in the dissolved-solids load and trend analysis to help assess the effects of agricultural areas that drain to the Green River in the Uinta Basin, but outside of the Duchesne River Basin.Estimated mean annual dissolved-solids loads for WY 1989–2013 ranged from 1,520 tons at Lake Fork River above Moon Lake, near Mountain Home, Utah (UT), to 1,760,000 tons at Green River near Green River, UT. The flow-normalized loads at gaging stations upstream of agricultural activities showed no trend or a relatively small change. The largest net change in modeled flow-normalized load was -352,000 tons (a 17.8-percent decrease) at Green River near Green River, UT.Annual streamflow and modeled dissolved-solids loads at the gaging stations were balanced between upstream and downstream sites to determine how much water and dissolved solids were transported to the Duchesne River and a section of the Green River, and how much was picked up in each drainage area. Mass-balance calculations of WY 1989–2013 mean annual dissolved-solids loads at the studied sites show that Green River near Jensen, UT, accounts for 64 percent of the load in the river at Green River, UT, while the Duchesne River and White River contribute 10 and 13 percent, respectively.Annual streamflow and modeled dissolved-solids loads at the gaging stations were balanced between upstream and downstream sites to determine how much water and dissolved solids were transported to the Duchesne River and a section of the Green River, and how much was picked up in each drainage area. Mass-balance calculations of WY 1989–2013 mean annual dissolved-solids loads at the studied sites show that Green River near Jensen, UT, accounts for 64 percent of the load in the river at Green River, UT, while the Duchesne River and White River contribute 10 and 13 percent, respectively.The flow-normalized dissolved-solids loads estimated at Duchesne River near Randlett, UT, and White River near Watson, UT, decreased by 68,000 and 55,300 tons, or 27.8 and 20.8 percent respectively, when comparing 1989 to 2013. The drainage basins for both rivers have undergone salinity-control projects since the early 1980s to reduce the dissolved-solids load entering the Colorado River. Approximately 19 percent of the net change in flow-normalized load at Green River at Green River, UT, is from changes in load modeled at Duchesne River near Randlett, UT, and 16 percent from changes in load modeled at White River near Watson, UT. The net change in flow-normalized load estimated at Green River near Greendale, UT, for WY 1989–2013 accounts for about 45 percent of the net change estimated at Green River at Green River, UT.Mass-balance calculations of WY 1989–2013 mean annual dissolved-solids loads at the studied sites in the Duchesne River Basin show that 75,400 tons or 44 percent of the load at the Duchesne River near Randlett, UT, gaging station was not accounted for at any of the upstream gages. Most of this unmonitored load is derived from tributary inflow, groundwater discharge, unconsumed irrigation water, and irrigation tail water.A mass balance of WY 1989–2013 flow-normalized loads estimated at sites in the Duchesne River Basin indicates that the flow-normalized load of unmonitored inflow to the Duchesne River between the Myton and Randlett gaging stations decreased by 38 percent. The total net decrease in flow-normalized load calculated for unmonitored inflow in the drainage basin accounts for 94 percent of the decrease in WY 1989–2013 flow-normalized load modeled at the Duchesne River near Randlett, UT, gaging station. Irrigation improvements in the drainage basin have likely contributed to the decrease in flow-normalized load.Reductions in dissolved-solids load estimated by the Natural Resources Conservation Service (NRCS) and the Bureau of Reclamation (Reclamation) from on- and off-farm improvements in the Uinta Basin totaled about 135,000 tons in 2013 (81,900 tons from on-farm improvements and 53,300 tons from off-farm improvements). The reduction in dissolved-solids load resulting from on- and off-farm improvements facilitated by the NRCS and Reclamation in the Price River Basin from 1989 to 2013 was estimated to be 64,800 tons.The amount of sprinkler-irrigated land mapped in the drainage area or subbasin area for a gaging station was used to estimate the reduction in load resulting from the conversion from flood to sprinkler irrigation. Sprinkler-irrigated land mapped in the Uinta Basin totaled 109,630 acres in 2012. Assuming conversion to wheel-line sprinklers, a reduction in dissolved-solids load in the Uinta Basin of 95,800 tons in 2012 was calculated using the sprinkler-irrigation acreage and a pre-salinity-control project dissolved-solids yield of 1.04 tons per acre.A reduction of 72,800 tons in dissolved-solids load from irrigation improvements was determined from sprinkler-irrigated lands in the Ashley Valley and Jensen, Pelican Lake, and Pleasant Valley areas (mapped in 2012); and in the Price River Basin (mapped in 2011). This decrease in dissolved-solids load is 8,800 tons more than the decrease in unmonitored flow-normalized dissolved-solids load (-64,000 tons) determined for the Green River between the Jensen and Green River gaging stations.The net WY 1989–2013 change in flow-normalized dissolved-solids load at the Duchesne River near Randlett, UT, and the Green River between the Jensen and Green River, UT, gaging stations determined from mass-balance calculations was compared to reported reductions in dissolved-solids load from on- and off-farm improvements and estimated reductions in load determined from mapped sprinkler-irrigated areas in the Duchesne River Basin and the area draining to the Green River between the Jensen and Green River gaging stations. The combined NRCS and Reclamation estimates of reduction in dissolved-solids load from on- and off-farm improvements in the study area (200,000 tons) is more than the reduction in load estimated using the acreage with sprinkler improvements (136,000 tons) or the mass-balance of flow-normalized load (132,000 tons).
Transverse Stress Decay in a Specially Orthotropic Strip Under Localizing Normal Edge Loading
NASA Technical Reports Server (NTRS)
Fichter, W. B.
2000-01-01
Solutions are presented for the stresses in a specially orthotropic infinite strip which is subjected to localized uniform normal loading on one edge while the other edge is either restrained against normal displacement only, or completely fixed. The solutions are used to investigate the diffusion of load into the strip and in particular the decay of normal stress across the width of the strip. For orthotropic strips representative of a broad range of balanced and symmetric angle-ply composite laminates, minimum strip widths are found that ensure at least 90% decay of the normal stress across the strip. In addition, in a few cases where, on the fixed edge the peak shear stress exceeds the normal stress in magnitude, minimum strip widths that ensure 90% decay of both stresses are found. To help in putting these results into perspective, and to illustrate the influence of material properties on load 9 orthotropic materials, closed-form solutions for the stresses in similarly loaded orthotropic half-planes are obtained. These solutions are used to generate illustrative stress contour plots for several representative laminates. Among the laminates, those composed of intermediate-angle plies, i.e., from about 30 degrees to 60 degrees, exhibit marked changes in normal stress contour shape with stress level. The stress contours are also used to find 90% decay distances in the half-planes. In all cases, the minimum strip widths for 90% decay of the normal stress exceed the 90% decay distances in the corresponding half-planes, in amounts ranging from only a few percent to about 50% of the half-plane decay distances. The 90% decay distances depend on both material properties and the boundary conditions on the supported edge.
Ergonomics and sitting at work.
Corlett, E N
2009-01-01
Many factors influence the performance at the workplace. The immediate interface between the user and the equipment is, perhaps, the most important. Hence, the arrangements of the seat and work point are critical.Factors which cause discomfort and injury to seated workers are described and, from the behaviour of the spine under load, a better seat design is presented. Its use by a wide variety of workers makes it necessary to introduce increased adjustability, beyond that normally part of conventional seat design. The application of the new design in two cases in industry, as well as its introduction in schools, is briefly covered.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Matyushichev, V.B.; Taratukhin, V.R.; Shamratova, V.G.
1978-01-01
The effectiveness of exposing rats to different doses of x radiation after submitting them to a heat load, according to the tests of ATPase and creatine kinase activity of aqueous extracts of skin at the relatively late observation period was compared. The effects of the combined factors were monitored by means of a heat load (one group) and exposure to radiation alone in doses of 25, 50, 100, 250, and 400 R (5 groups). The obtained data are indicative of marked specificity of ATPase and creatine kinase reactions to the combined factors. Creatine kinase activity undergoes a 157% change, whereasmore » the mean relative deviation of ATPase activity constitutes only 71% of the normal level. The most effect loads are 36/sup 0/C + 25 R and 36/sup 0/C + 400 R. With all tested doses the extent of the effect of radiation on creatine kinase activity is only negligibly lower than the effectiveness of combined loads, whereas according to the ATPase test, radiation alone induces virtually the same changes in activity as combined factors. ATPase undergoes maximum change after irradiation in doses of 250 and 400 R; delivery of 25 to 100 R is associated with much less marked changes in activity. In contrast, creatine kinase demonstrates maximum sensitivity to radiation in a dosage of 25 R and minimum sensitivity, with a dosage of 100 R. Thermal stress (according to ATPase and creatine kinase activity) has a profound and quite substantial effect on processes of development of radiation lesion. It can be manifested by complete or partial summation of effects of each of the factors, mutual attenuation of effects, or absence of interaction between factors in the combination. All this is indicative of the complexity and differences in mechanisms of expression of effects of the factors used. (ERB)« less
NASA Astrophysics Data System (ADS)
Jordan, Yuyan C.; Ghulam, Abduwasit; Hartling, Sean
2014-01-01
In this paper, spatial and temporal trajectories of land cover/land use change (LCLUC) derived from Landsat data record are combined with hydrological modeling to explore the implication of vegetation dynamics on soil erosion and total suspended sediment (TSS) loading to surface rivers. The inter-annual coefficient of variation (CoV) of normalized difference vegetation index (NDVI) is used to screen the LCLUC and climate change. The Soil and Water Assessment Tool (SWAT) is employed to identify the monthly TSS for two times interval (1991 to 2001 and 2001 to 2011) at subbasin levels. SWAT model is calibrated from 1991 to 2001 and validated from 2002 to 2011 at three USGS gauging sites located in the study area. The Spearman's rank correlation of annual mean TSS is used to assess the temporal trends of TSS dynamics in the subbasins in the two study periods. The spatial correlation among NDVI, LCLUC, climate change and TSS loading rate changes is quantified by using linear regression model and negative/positive trend analysis. Our results showed that higher rainfall yields contribute to higher TSS loading into surface waters. A higher inter-annual accumulated vegetation index and lower inter-annual CoV distributed over the uplands resulted in a lower TSS loading rate, while a relatively low vegetation index with larger CoV observed over lowlands resulted in a higher TSS loading rate. The TSS loading rate at the basin outlet increased with the decrease of annual NDVI due to expanding urban areas in the watershed. The results also suggested nonlinearity between the trends of TSS loading with any of a specific land cover change because of the fact that the contribution of a factor can be influenced by the effects of other factors. However, dominant factors that shape the relationship between the trend of TSS loading and specific land cover changes were detected. The change of forest showed a negative relationship while agriculture and pasture demonstrated positive relationships with TSS loading change. Our results do not show any significant causal relationship between urbanization and the TSS loading change suggesting that further investigation needs to be carried out to understand the mechanism of the impact of urban sprawl on surface water quality.
Reaction times of normal listeners to laryngeal, alaryngeal, and synthetic speech.
Evitts, Paul M; Searl, Jeff
2006-12-01
The purpose of this study was to compare listener processing demands when decoding alaryngeal compared to laryngeal speech. Fifty-six listeners were presented with single words produced by 1 proficient speaker from 5 different modes of speech: normal, tracheosophageal (TE), esophageal (ES), electrolaryngeal (EL), and synthetic speech (SS). Cognitive processing load was indexed by listener reaction time (RT). To account for significant durational differences among the modes of speech, an RT ratio was calculated (stimulus duration divided by RT). Results indicated that the cognitive processing load was greater for ES and EL relative to normal speech. TE and normal speech did not differ in terms of RT ratio, suggesting fairly comparable cognitive demands placed on the listener. SS required greater cognitive processing load than normal and alaryngeal speech. The results are discussed relative to alaryngeal speech intelligibility and the role of the listener. Potential clinical applications and directions for future research are also presented.
Brain tissue volumes in the general elderly population. The Rotterdam Scan Study.
Ikram, M Arfan; Vrooman, Henri A; Vernooij, Meike W; van der Lijn, Fedde; Hofman, Albert; van der Lugt, Aad; Niessen, Wiro J; Breteler, Monique M B
2008-06-01
We investigated how volumes of cerebrospinal fluid (CSF), grey matter (GM) and white matter (WM) varied with age, sex, small vessel disease and cardiovascular risk factors in the Rotterdam Scan Study. Participants (n=490; 60-90 years) were non-demented and 51.0% had hypertension, 4.9% had diabetes mellitus, 17.8% were current smoker and 54.0% were former smoker. We segmented brain MR-images into GM, normal WM, white matter lesion (WML) and CSF. Brain infarcts were rated visually. Volumes were expressed as percentage of intra-cranial volume. With increasing age, volumes of total brain, normal WM and total WM decreased; that of GM remained unchanged; and that of WML increased, in both men and women. Excluding persons with infarcts did not alter these results. Persons with larger load of small vessel disease had smaller brain volume, especially normal WM volume. Diastolic blood pressure, diabetes mellitus and current smoking were also related to smaller brain volume. In the elderly, higher age, small vessel disease and cardiovascular risk factors are associated with smaller brain volume, especially WM volume.
Trabecular bone adaptation to low-magnitude high-frequency loading in microgravity.
Torcasio, Antonia; Jähn, Katharina; Van Guyse, Maarten; Spaepen, Pieter; Tami, Andrea E; Vander Sloten, Jos; Stoddart, Martin J; van Lenthe, G Harry
2014-01-01
Exposure to microgravity causes loss of lower body bone mass in some astronauts. Low-magnitude high-frequency loading can stimulate bone formation on earth. Here we hypothesized that low-magnitude high-frequency loading will also stimulate bone formation under microgravity conditions. Two groups of six bovine cancellous bone explants were cultured at microgravity on a Russian Foton-M3 spacecraft and were either loaded dynamically using a sinusoidal curve or experienced only a static load. Comparable reference groups were investigated at normal gravity. Bone structure was assessed by histology, and mechanical competence was quantified using μCT and FE modelling; bone remodelling was assessed by fluorescent labelling and secreted bone turnover markers. Statistical analyses on morphometric parameters and apparent stiffness did not reveal significant differences between the treatment groups. The release of bone formation marker from the groups cultured at normal gravity increased significantly from the first to the second week of the experiment by 90.4% and 82.5% in response to static and dynamic loading, respectively. Bone resorption markers decreased significantly for the groups cultured at microgravity by 7.5% and 8.0% in response to static and dynamic loading, respectively. We found low strain magnitudes to drive bone turnover when applied at high frequency, and this to be valid at normal as well as at microgravity. In conclusion, we found the effect of mechanical loading on trabecular bone to be regulated mainly by an increase of bone formation at normal gravity and by a decrease in bone resorption at microgravity. Additional studies with extended experimental time and increased samples number appear necessary for a further understanding of the anabolic potential of dynamic loading on bone quality and mechanical competence.
Demarzo, Arthur P
2009-01-01
Early detection of cardiovascular disease (CVD) could initiate appropriate treatment and prevent progression. This study used impedance cardiography (ICG) waveform analysis with postural change to detect functional CVD in women older than 40 years with no history of CVD and >or=2 of the following risk factors: cigarette smoking, poor diet, physical inactivity, central adiposity, family history of premature CVD, hypertension, and dyslipidemia. A study group of 32 women underwent ICG in standing and supine positions. An age-matched control group had 20 women with an active lifestyle, no risk factors, and no history of CVD. All women in the control group had normal ICG data. All women in the study group had some abnormal ICG data, with 28 (87.5%) having multiple ICG abnormalities. ICG data indicated that 13 (40.6%) had ventricular dysfunction, 14 (43.8%) had high vascular resistive load, and 30 (93.8%) had elevated vascular pulsatile load. The data suggest that subclinical CVD, detectable by ICG, is prevalent in women older than 40 years with multiple risk factors. Abnormal ICG results could expedite the initiation of customized treatment as part of a preventive approach to CVD. (c) 2009 Wiley Periodicals, Inc.
14 CFR 23.365 - Pressurized cabin loads.
Code of Federal Regulations, 2011 CFR
2011-01-01
... landing. (d) The airplane structure must be strong enough to withstand the pressure differential loads... AIRWORTHINESS STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Structure Flight Loads § 23... structure must be strong enough to withstand the flight loads combined with pressure differential loads from...
Stability and failure analysis of steering tie-rod
NASA Astrophysics Data System (ADS)
Jiang, GongFeng; Zhang, YiLiang; Xu, XueDong; Ding, DaWei
2008-11-01
A new car in operation of only 8,000 km, because of malfunction, resulting in lost control and rammed into the edge of the road, and then the basic vehicle scrapped. According to the investigation of the site, it was found that the tie-rod of the car had been broken. For the subjective analysis of the accident and identifying the true causes of rupture of the tierod, a series of studies, from the angle of theory to experiment on the bended broken tie-rod, were conducted. The mechanical model was established; the stability of the defective tie-rod was simulated based on ANSYS software. Meanwhile, the process of the accident was simulated considering the effect of destabilization of different vehicle speed and direction of the impact. Simultaneously, macro graphic test, chemical composition analysis, microstructure analysis and SEM analysis of the fracture were implemented. The results showed that: 1) the toughness of the tie-rod is at a normal level, but there is some previous flaws. One quarter of the fracture surface has been cracked before the accident. However, there is no relationship between the flaw and this incident. The direct cause is the dynamic instability leading to the large deformation of impact loading. 2) The declining safety factor of the tie-rod greatly due to the previous flaws; the result of numerical simulation shows that previous flaw is the vital factor of structure instability, on the basis of the comparison of critical loads of the accident tie-rod and normal. The critical load can decrease by 51.3% when the initial defect increases 19.54% on the cross-sectional area, which meets the Theory of Koiter.
NASA Astrophysics Data System (ADS)
Goncharov, K. A.; Denisov, I. A.
2017-10-01
The article considers the influence of the air gap size between the linear motor elements on the stability of the traction drive of the movement mechanism of the trolley of the bridge type crane. The main factors affecting the air gap size and the causes of their occurrence are described. The technique of calculating the magnitude of air gap variation is described in relation to the general deformation of the crane metal structure. Recommendations on the need for installation of additional equipment for load trolleys of various designs are given. The optimal values of the length of the trolley base are proposed. Observance of these values ensures normal operation of the traction drive.
Determination of the Fracture Parameters in a Stiffened Composite Panel
NASA Technical Reports Server (NTRS)
Lin, Chung-Yi
2000-01-01
A modified J-integral, namely the equivalent domain integral, is derived for a three-dimensional anisotropic cracked solid to evaluate the stress intensity factor along the crack front using the finite element method. Based on the equivalent domain integral method with auxiliary fields, an interaction integral is also derived to extract the second fracture parameter, the T-stress, from the finite element results. The auxiliary fields are the two-dimensional plane strain solutions of monoclinic materials with the plane of symmetry at x(sub 3) = 0 under point loads applied at the crack tip. These solutions are expressed in a compact form based on the Stroh formalism. Both integrals can be implemented into a single numerical procedure to determine the distributions of stress intensity factor and T-stress components, T11, T13, and thus T33, along a three-dimensional crack front. The effects of plate thickness and crack length on the variation of the stress intensity factor and T-stresses through the thickness are investigated in detail for through-thickness center-cracked plates (isotropic and orthotropic) and orthotropic stiffened panels under pure mode-I loading conditions. For all the cases studied, T11 remains negative. For plates with the same dimensions, a larger size of crack yields larger magnitude of the normalized stress intensity factor and normalized T-stresses. The results in orthotropic stiffened panels exhibit an opposite trend in general. As expected, for the thicker panels, the fracture parameters evaluated through the thickness, except the region near the free surfaces, approach two-dimensional plane strain solutions. In summary, the numerical methods presented in this research demonstrate their high computational effectiveness and good numerical accuracy in extracting these fracture parameters from the finite element results in three-dimensional cracked solids.
Complement activation promotes muscle inflammation during modified muscle use
NASA Technical Reports Server (NTRS)
Frenette, J.; Cai, B.; Tidball, J. G.
2000-01-01
Modified muscle use can result in muscle inflammation that is triggered by unidentified events. In the present investigation, we tested whether the activation of the complement system is a component of muscle inflammation that results from changes in muscle loading. Modified rat hindlimb muscle loading was achieved by removing weight-bearing from the hindlimbs for 10 days followed by reloading through normal ambulation. Experimental animals were injected with the recombinant, soluble complement receptor sCR1 to inhibit complement activation. Assays for complement C4 or factor B in sera showed that sCR1 produced large reductions in the capacity for activation of the complement system through both the classical and alternative pathways. Analysis of complement C4 concentration in serum in untreated animals showed that the classical pathway was activated during the first 2 hours of reloading. Analysis of factor B concentration in untreated animals showed activation of the alternative pathway at 6 hours of reloading. Administration of sCR1 significantly attenuated the invasion of neutrophils (-49%) and ED1(+) macrophages (-52%) that occurred in nontreated animals after 6 hours of reloading. The presence of sCR1 also reduced significantly the degree of edema by 22% as compared to untreated animals. Together, these data show that increased muscle loading activated the complement system which then briefly contributes to the early recruitment of inflammatory cells during modified muscle loading.
Load measurement system with load cell lock-out mechanism
NASA Technical Reports Server (NTRS)
Le, Thang; Carroll, Monty; Liu, Jonathan
1995-01-01
In the frame work of the project Shuttle Plume Impingement Flight Experiment (SPIFEX), a Load Measurement System was developed and fabricated to measure the impingement force of Shuttle Reaction Control System (RCS) jets. The Load Measurement System is a force sensing system that measures any combination of normal and shear forces up to 40 N (9 lbf) in the normal direction and 22 N (5 lbf) in the shear direction with an accuracy of +/- 0.04 N (+/- 0.01 lbf) Since high resolution is required for the force measurement, the Load Measurement System is built with highly sensitive load cells. To protect these fragile load cells in the non-operational mode from being damaged due to flight loads such as launch and landing loads of the Shuttle vehicle, a motor driven device known as the Load Cell Lock-Out Mechanism was built. This Lock-Out Mechanism isolates the load cells from flight loads and re-engages the load cells for the force measurement experiment once in space. With this highly effective protection system, the SPIFEX load measurement experiment was successfully conducted on STS-44 in September 1994 with all load cells operating properly and reading impingement forces as expected.
Matyas, J R; Huang, D; Adams, M E
1999-01-01
Several approaches are commonly used to normalize variations in RNA loading on Northern blots, including: ethidium bromide (EthBr) fluorescence of 18S or 28S rRNA or autoradiograms of radioactive probes hybridized with constitutively expressed RNAs such as elongation factor-1alpha (ELF), glyceraldehyde-3-phosphate dehydrogenase (G3PDH), actin, 18S or 28S rRNA, or others. However, in osteoarthritis (OA) the amount of total RNA changes significantly and none of these RNAs has been clearly demonstrated to be expressed at a constant level, so it is unclear if any of these approaches can be used reliably for normalizing RNA extracted from osteoarthritic cartilage. Total RNA was extracted from normal and osteoarthritic cartilage and assessed by EthBr fluorescence. RNA was then transferred to a nylon membrane hybridized with radioactive probes for ELF, G3PDH, Max, actin, and an oligo-dT probe. The autoradiographic signal across the six lanes of a gel was quantified by scanning densitometry. When compared on the basis of total RNA, the coefficient of variation was lowest for 28S ethidium bromide fluorescence and oligo-dT (approximately 7%), followed by 18S ethidium bromide fluorescence and G3PDH (approximately 13%). When these values were normalized to DNA concentration, the coefficient of variation exceeded 50% for all signals. Total RNA and the signals for 18S, 28S rRNA, and oligo-dT all correlated highly. These data indicate that osteoarthritic chondrocytes express similar ratios of mRNA to rRNA and mRNA to total RNA as do normal chondrocytes. Of all the "housekeeping" probes, G3PDH correlated best with the measurements of RNA. All of these "housekeeping" probes are expressed at greater levels by osteoarthritic chondrocytes when compared with normal chondrocytes. Thus, while G3PDH is satisfactory for evaluating the amount of RNA loaded, its level of expression is not the same in normal and osteoarthritic chondrocytes.
NASA Astrophysics Data System (ADS)
Li, Yaokun; Han, Xiaolei; Galal, Khaled; Ji, Jing
2018-01-01
Cushion is a layer of granular materials between the raft and the ground. The shear behavior of the interface between the cushion and the raft may influence the seismic performance of the superstructure. In order to quantify such influences, horizontal shear tests on the interfaces between different cushion materials and concrete raft under monotonic and cyclic loading were carried out. The vertical pressure P v, material type and cushion thickness h c were taken as variables. Conclusions include: 1) under monotonic loading, P v is the most significant factor; the shear resistance P hmax increases as P v increases, but the normalized factor of resistance μ n has an opposite tendency; 2) for the materials used in this study, μ n varies from 0.40 to 0.70, the interface friction angle δ s varies from 20° to 35°, while u max varies from 3 mm to 15 mm; 3) under cyclic loading, the interface behavior can be abstracted as a "three-segment" back-bone curve, the main parameters include μ n, the displacement u 1 and stiffness K 1 of the elastic stage, the displacement u 2 and stiffness K 2 of the plastic stage; 4) by observation and statistical analysis, the significance of different factors, together with values of K 1, K 2 and μ n have been obtained.
14 CFR 27.337 - Limit maneuvering load factor.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Limit maneuvering load factor. 27.337... Limit maneuvering load factor. The rotorcraft must be designed for— (a) A limit maneuvering load factor... load factor not less than 2.0 and any negative limit maneuvering load factor of not less than −0.5 for...
14 CFR 29.337 - Limit maneuvering load factor.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Limit maneuvering load factor. 29.337... Limit maneuvering load factor. The rotorcraft must be designed for— (a) A limit maneuvering load factor... load factor not less than 2.0 and any negative limit maneuvering load factor of not less than −0.5 for...
Dynamic analysis of elastic rubber tired car wheel breaking under variable normal load
NASA Astrophysics Data System (ADS)
Fedotov, A. I.; Zedgenizov, V. G.; Ovchinnikova, N. I.
2017-10-01
The purpose of the paper is to analyze the dynamics of the braking of the wheel under normal load variations. The paper uses a mathematical simulation method according to which the calculation model of an object as a mechanical system is associated with a dynamically equivalent schematic structure of the automatic control. Transfer function tool analyzing structural and technical characteristics of an object as well as force disturbances were used. It was proved that the analysis of dynamic characteristics of the wheel subjected to external force disturbances has to take into account amplitude and phase-frequency characteristics. Normal load variations impact car wheel braking subjected to disturbances. The closer slip to the critical point is, the higher the impact is. In the super-critical area, load variations cause fast wheel blocking.
Di Bonito, Procolo; Licenziati, Maria Rosaria; Baroni, Marco Giorgio; Congiu, Tiziana; Incani, Michela; Iannuzzi, Arcangelo; Maffeis, Claudio; Perrone, Laura; Valerio, Giuliana; Del Giudice, Emanuele Miraglia
2014-08-01
To evaluate normoglycemic overweight/obese (Ow/Ob) children whose post-load plasma glucose (2hPG) cut-point may be significantly associated with cardiometabolic risk factors (CMRFs) and whether this cut-point predicts preclinical signs of organ damage. One thousand seven hundred and thrity four normoglycemic Ow/Ob children were stratified into quintiles of 2hPG, the sixth group was constituted by 101 children with impaired glucose tolerance (IGT). Moving from the lower quintiles of 2hPG to IGT, the groups differed for Prepubertal stage, BMI, fasting PG, insulin levels, blood pressure, and lipids. To evaluate the best cut-off of 2hPG related to CMRFs, the area under the receiver operating characteristic curve and the Youden's index was calculated. Insulin resistance, high blood pressure, and high triglyceride/HDL-C ratio were associated with a 2hPG cut-off of 110 mg/dl. Children with 2hPG ≥110 mg/dl showed 1.3-3.2 fold higher risk to have high levels of ALT (as surrogate of nonalcoholic fatty liver disease) or increased carotid intima-media thickness. This study, performed in a large cohort of Ow/Ob children, shows that an atherogenic risk profile and preclinical signs of organ damage are associated with post-challenge elevations in plasma glucose still considered in the high normal range. Copyright © 2014 The Obesity Society.
Clinical Factors and Viral Load Influencing Severity of Acute Hepatitis A.
Lee, Hyun Woong; Chang, Dong-Yeop; Moon, Hong Ju; Chang, Hye Young; Shin, Eui-Cheol; Lee, June Sung; Kim, Kyung-Ah; Kim, Hyung Joon
2015-01-01
Clinical manifestations of hepatitis A virus (HAV) infection vary from mild to fulminant hepatic failure (FHF) in adults. We investigated the relationship between laboratory findings, including viral load, and clinical outcomes in patients with acute hepatitis A (AHA) and evaluated predictive factors for severe acute hepatitis (s-AH). We analyzed the clinical manifestations of AHA in 770 patients. Patients with a prothrombin time (PT) of less than 40% of normal were classified as s-AH and included 4 patients with FHF, 11 patients with acute renal failure, and 3 patients with prolonged jaundice (n = 128). Other patients were defined as mild acute hepatitis (m-AH) (n = 642). Serum samples were obtained from 48 patients with acute hepatitis A. Among them, 20 with s-AH, and 28 with m-AH, were tested for HAV RNA titer. In a multivariate analysis, age (HR = 1.042, P = 0.041), peak creatinine (HR = 4.014, P = 0.001), bilirubin (HR = 1.153, P = 0.003), alanine aminotransferase (ALT) (HR = 1.001, P < 0.001), initial lactate dehydrogenase (LDH) (HR = 1.000, P = 0.045) and total cholesterol (HR = 0.978, P < 0.001) were independent factors for s-AH. Serum HAV RNA was detected in 20/20 (100%) patients with s-AH and 22/28 (78.6%) patients with m-AH. In a multivariate analysis of the 48 patients who were tested for HAV RNA, peak ALT (HR = 1.001, P = 0.004) and HAV RNA titer (HR = 2.076, P = 0.012) were independent factors for s-AH. Clinical factors including age, peak creatinine, bilirubin, ALT, initial LDH and total cholesterol were independent factors for s-AH in a multivariate analysis. In particular, HAV load strongly correlated with the severity of hepatitis A.
Clinical Factors and Viral Load Influencing Severity of Acute Hepatitis A
Lee, Hyun Woong; Chang, Dong-Yeop; Moon, Hong Ju; Chang, Hye Young; Shin, Eui-Cheol; Lee, June Sung; Kim, Kyung-Ah; Kim, Hyung Joon
2015-01-01
Background and Aims Clinical manifestations of hepatitis A virus (HAV) infection vary from mild to fulminant hepatic failure (FHF) in adults. We investigated the relationship between laboratory findings, including viral load, and clinical outcomes in patients with acute hepatitis A (AHA) and evaluated predictive factors for severe acute hepatitis (s-AH). Methods We analyzed the clinical manifestations of AHA in 770 patients. Patients with a prothrombin time (PT) of less than 40% of normal were classified as s-AH and included 4 patients with FHF, 11 patients with acute renal failure, and 3 patients with prolonged jaundice (n = 128). Other patients were defined as mild acute hepatitis (m-AH) (n = 642). Serum samples were obtained from 48 patients with acute hepatitis A. Among them, 20 with s-AH, and 28 with m-AH, were tested for HAV RNA titer. Results In a multivariate analysis, age (HR = 1.042, P = 0.041), peak creatinine (HR = 4.014, P = 0.001), bilirubin (HR = 1.153, P = 0.003), alanine aminotransferase (ALT) (HR = 1.001, P<0.001), initial lactate dehydrogenase (LDH) (HR = 1.000, P = 0.045) and total cholesterol (HR = 0.978, P<0.001) were independent factors for s-AH. Serum HAV RNA was detected in 20/20 (100%) patients with s-AH and 22/28 (78.6%) patients with m-AH. In a multivariate analysis of the 48 patients who were tested for HAV RNA, peak ALT (HR = 1.001, P = 0.004) and HAV RNA titer (HR = 2.076, P = 0.012) were independent factors for s-AH. Conclusions Clinical factors including age, peak creatinine, bilirubin, ALT, initial LDH and total cholesterol were independent factors for s-AH in a multivariate analysis. In particular, HAV load strongly correlated with the severity of hepatitis A. PMID:26090677
Ground reaction forces and plantar pressure distribution during occasional loaded gait.
Castro, Marcelo; Abreu, Sofia; Sousa, Helena; Machado, Leandro; Santos, Rubim; Vilas-Boas, João Paulo
2013-05-01
This study compared the ground reaction forces (GRF) and plantar pressures between unloaded and occasional loaded gait. The GRF and plantar pressures of 60 participants were recorded during unloaded gait and occasional loaded gait (wearing a backpack that raised their body mass index to 30); this load criterion was adopted because is considered potentially harmful in permanent loaded gait (obese people). The results indicate an overall increase (absolute values) of GRF and plantar pressures during occasional loaded gait (p < 0.05); also, higher normalized (by total weight) values in the medial midfoot and toes, and lower values in the lateral rearfoot region were observed. During loaded gait the magnitude of the vertical GRF (impact and thrust maximum) decreased and the shear forces increased more than did the proportion of the load (normalized values). These data suggest a different pattern of GRF and plantar pressure distribution during occasional loaded compared to unloaded gait. Copyright © 2012 Elsevier Ltd and The Ergonomics Society. All rights reserved.
14 CFR 23.337 - Limit maneuvering load factors.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Limit maneuvering load factors. 23.337... Flight Loads § 23.337 Limit maneuvering load factors. (a) The positive limit maneuvering load factor n... airplanes; or (3) 6.0 for acrobatic category airplanes. (b) The negative limit maneuvering load factor may...
MEPDG Traffic Loading Defaults Derived from Traffic Pooled Fund Study
DOT National Transportation Integrated Search
2016-04-01
As part of traffic loading inputs, the Mechanistic-Empirical Pavement Design Guide (MEPDG), Interim Edition: A Manual of Practice requires detailed axle loading information in the form of normalized axle load spectra (NALS), number of axle per truck ...
Do Integrins Mediate the Skeletal Response to Altered Loading?
NASA Technical Reports Server (NTRS)
vanderMeulen, Marjolein C. H.
2004-01-01
In vivo experiments were performed to examine the role of B1 integrin in skeletal adaptation to reduced and increased loading. Transgenic mice were generated with a dominant negative form of the B1 integrin cytoplasmic domain with expression driven by the osteocalcin promoter (pOCb1DN). This fragment consists of the transmembrane and intracellular domains and interferes with endogenous integrin signalling in vitro. This promoter targets expression of the transgene to mature bone cells. Expression of the transgene was confirmed by immunoprecipitation and western blotting. Reduced loading was generated by hindlimb suspension and increased loading the resumption of normal loading following hindlimb suspension. Two groups of female 35-day old mice were examined: poCb1DN transgenic mice (TG) and wild-type littermate controls (WT). Animals were hindlimb suspended for 1 week (HU, n = l0/gp) or 4 weeks (HU, n = 4 - 7/gp) or suspended for 4 weeks followed by reloading by normal ambulation for 4 weeks (RL, n = l0/gp). Age-matched controls (CT) were pairfed based on the HU food intake. The protocols were approved by the NASA Ames Research Center IACUC. Upon completion of the experimental protocol, body mass was recorded and tissues of interest removed and analyzed following standard procedures. Femoral whole bone structural behavior was measured in torsion to failure to obtain whole bone strength (failure torque) and torsional rigidity. Ash content (ash) and fraction (% ash) were determined for the tibia. Total ash is indicative of bone size whereas %ash is a material property. Tibial curvature was measured from microradiographs. For each experiment, the effects of genotype (TG, WT) and treatment (CT, HU/RL) were assessed by two-factor ANOVA followed by the Tukey-Kramer posthoc to identify significant differences at an alpha level of 0.05. Our goal was to understand differences resulting from altered integrin function in the adaptation to altered loading.
Gray, Robert J; Voegeli, David; Bader, Dan L
2016-02-01
Impaired lymph formation and clearance has previously been proposed as a contributory factor in the development of pressure ulcers. The present study has been designed to trial fluorescence lymphangiography for establishing how lymphatic function is altered under a clinically relevant form of mechanical loading. Lymph formation and clearance was traced in both forearms by an intradermal injection of indocyanine green (ICG) (50 μl, 0.05%w/v), imaged using a commercial near-infrared fluorescence imaging unit (Fluobeam(®) 800). External uniaxial loading equivalent to a pressure of 60 mmHg was applied for 45 min in one arm using a custom-built indenter. Loading was associated with a decreased frequency of normal directional drainage (DD) of ICG within delineated vessels, both immediately after loading and 45 min thereafter. Loading was also associated with non-directional drainage (NDD) of ICG within the interstitium. Signal intensity within NDD was often greatest at areas of stress concentration, producing a 'halo pattern', corresponding to the rounded edges of the indenter. These results suggest that loading skin with a clinically relevant magnitude of pressure alters both lymph formation and clearance. Further work to quantify impaired clearance under mechanical loading could provide valuable insight into their involvement in the development of pressure ulcers. Copyright © 2016 Tissue Viability Society. Published by Elsevier Ltd. All rights reserved.
Gómez-Novo, Miriam; Boga, José A; Álvarez-Argüelles, Marta E; Rojo-Alba, Susana; Fernández, Ana; Menéndez, María J; de Oña, María; Melón, Santiago
2018-05-01
Human respiratory syncytial virus (HRSV) is a common cause of respiratory infections. The main objective is to analyze the prediction ability of viral load of HRSV normalized by cell number in respiratory symptoms. A prospective, descriptive, and analytical study was performed. From 7307 respiratory samples processed between December 2014 to April 2016, 1019 HRSV-positive samples, were included in this study. Low respiratory tract infection was present in 729 patients (71.54%). Normalized HRSV load was calculated by quantification of HRSV genome and human β-globin gene and expressed as log10 copies/1000 cells. HRSV mean loads were 4.09 ± 2.08 and 4.82 ± 2.09 log10 copies/1000 cells in the 549 pharyngeal and 470 nasopharyngeal samples, respectively (P < 0.001). The viral mean load was 4.81 ± 1.98 log10 copies/1000 cells for patients under the age of 4-year-old (P < 0.001). The viral mean loads were 4.51 ± 2.04 cells in patients with low respiratory tract infection and 4.22 ± 2.28 log10 copies/1000 cells with upper respiratory tract infection or febrile syndrome (P < 0.05). A possible cut off value to predict LRTI evolution was tentatively established. Normalization of viral load by cell number in the samples is essential to ensure an optimal virological molecular diagnosis avoiding that the quality of samples affects the results. A high viral load can be a useful marker to predict disease progression. © 2018 Wiley Periodicals, Inc.
Microstructure and tribological properties of TiCu2Al intermetallic compound coating
NASA Astrophysics Data System (ADS)
Guo, Chun; Zhou, Jiansong; Zhao, Jierong; Wang, Linqian; Yu, Youjun; Chen, Jianmin; Zhou, Huidi
2011-04-01
TiCu2Al ternary intermetallic compound coating has been in situ synthesized successfully on pure Ti substrate by laser cladding. Tribological properties of the prepared TiCu2Al intermetallic compound coating were systematically evaluated. It was found that the friction coefficient and wear rate was closely related to the normal load and sliding speed, i.e., the friction coefficient of the prepared TiCu2Al intermetallic compound coating decreased with increasing normal load and sliding speed. The wear rate of the TiCu2Al intermetallic compound coating decreased rapidly with increasing sliding speed, while the wear rate first increased and then decreased at normal load from 5 to 15 N.
NASA Technical Reports Server (NTRS)
Zahm, A F; Crook, L H
1918-01-01
Report presents stress analysis of individual components of an airplane. Normal and abnormal loads, sudden loads, simple stresses, indirect simple stresses, resultant unit stress, repetitive and equivalent stress, maximum steady load and stress are considered.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Gust loads. 27.341 Section 27.341 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: NORMAL CATEGORY ROTORCRAFT Strength Requirements Flight Loads § 27.341 Gust loads. The rotorcraft...
Code of Federal Regulations, 2011 CFR
2011-01-01
... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Gust loads. 27.341 Section 27.341 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: NORMAL CATEGORY ROTORCRAFT Strength Requirements Flight Loads § 27.341 Gust loads. The rotorcraft...
14 CFR 27.681 - Limit load static tests.
Code of Federal Regulations, 2013 CFR
2013-01-01
... AIRWORTHINESS STANDARDS: NORMAL CATEGORY ROTORCRAFT Design and Construction Control Systems § 27.681 Limit load... which— (1) The direction of the test loads produces the most severe loading in the control system; and... requirements for control system joints subject to angular motion. ...
Moen, Kent G; Brezova, Veronika; Skandsen, Toril; Håberg, Asta K; Folvik, Mari; Vik, Anne
2014-09-01
The aim of this study was to explore the prognostic value of visible traumatic axonal injury (TAI) loads in different MRI sequences from the early phase after adjusting for established prognostic factors. Likewise, we sought to explore the prognostic role of early apparent diffusion coefficient (ADC) values in normal-appearing corpus callosum. In this prospective study, 128 patients (mean age, 33.9 years; range, 11-69) with moderate (n = 64) and severe traumatic brain injury (TBI) were examined with MRI at a median of 8 days (range, 0-28) postinjury. TAI lesions in fluid-attenuated inversion recovery (FLAIR), diffusion-weighted imaging (DWI), and T2*-weighted gradient echo (T2*GRE) sequences were counted and FLAIR lesion volumes estimated. In patients and 47 healthy controls, mean ADC values were computed in 10 regions of interests in the normal-appearing corpus callosum. Outcome measure was the Glasgow Outcome Scale-Extended (GOS-E) at 12 months. In patients with severe TBI, number of DWI lesions and volume of FLAIR lesions in the corpus callosum, brain stem, and thalamus predicted outcome in analyses with adjustment for age, Glasgow Coma Scale score, and pupillary dilation (odds ratio, 1.3-6.9; p = <0.001-0.017). The addition of Rotterdam CT score and DWI lesions in the corpus callosum yielded the highest R2 (0.24), compared to all other MRI variables, including brain stem lesions. For patients with moderate TBI only the number of cortical contusions (p = 0.089) and Rotterdam CT score (p = 0.065) tended to predict outcome. Numbers of T2*GRE lesions did not affect outcome. Mean ADC values in the normal-appearing corpus callosum did not differ from controls. In conclusion, the loads of visible TAI lesions in the corpus callosum, brain stem, and thalamus in DWI and FLAIR were independent prognostic factors in patients with severe TBI. DWI lesions in the corpus callosum were the most important predictive MRI variable. Interestingly, number of cortical contusions in MRI and CT findings seemed more important for patients with moderate TBI.
14 CFR 23.485 - Side load conditions.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Side load conditions. 23.485 Section 23.485... STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Structure Ground Loads § 23.485 Side load conditions. (a) For the side load condition, the airplane is assumed to be in a level attitude...
14 CFR 23.485 - Side load conditions.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Side load conditions. 23.485 Section 23.485... STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Structure Ground Loads § 23.485 Side load conditions. (a) For the side load condition, the airplane is assumed to be in a level attitude...
14 CFR 23.485 - Side load conditions.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Side load conditions. 23.485 Section 23.485... STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Structure Ground Loads § 23.485 Side load conditions. (a) For the side load condition, the airplane is assumed to be in a level attitude...
Cointegration as a data normalization tool for structural health monitoring applications
NASA Astrophysics Data System (ADS)
Harvey, Dustin Y.; Todd, Michael D.
2012-04-01
The structural health monitoring literature has shown an abundance of features sensitive to various types of damage in laboratory tests. However, robust feature extraction in the presence of varying operational and environmental conditions has proven to be one of the largest obstacles in the development of practical structural health monitoring systems. Cointegration, a technique adapted from the field of econometrics, has recently been introduced to the SHM field as one solution to the data normalization problem. Response measurements and feature histories often show long-run nonstationarity due to fluctuating temperature, load conditions, or other factors that leads to the occurrence of false positives. Cointegration theory allows nonstationary trends common to two or more time series to be modeled and subsequently removed. Thus, the residual retains sensitivity to damage with dependence on operational and environmental variability removed. This study further explores the use of cointegration as a data normalization tool for structural health monitoring applications.
14 CFR 25.1531 - Maneuvering flight load factors.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Maneuvering flight load factors. 25.1531... Operating Limitations § 25.1531 Maneuvering flight load factors. Load factor limitations, not exceeding the positive limit load factors determined from the maneuvering diagram in § 25.333(b), must be established. ...
1976-07-16
Influence of Range 10 5 Range Performance Penalty Function II 6 Influence of Closing Velocity 12 7 Energy Influence Function 14 8 Comparison of the...flELtSHAlL, ..E^) RANGE RANGE Figure 7 Energy Influence Function 14 TM 76-1 SA ! PERFORMANCE INDEX COMPARATIVE ANALYSIS Maneuver Conversion Model...hnergy Integral ■’> E s K Energy Influence Function K* Proportionality Constant MT Target Mach Number N Normal Acceleration (load factor) z
Hempfling, H; Husemann, B
1975-06-01
1. Glucose loading tests were undertaken on isolated pancreas or pancreas-duodenal preparations. 2. In 75% of cases a vasodilatation can be observed which leads to enhanced blood circulation under constant pressure in the isolated organ. 3. This vasodilatation persists until the level of blood sugar has normalized. 4. The experiment being carried out on an isolated organ, external factors such as the vagus nerve, do not become active.
Strength of Gamma Rhythm Depends on Normalization
Ray, Supratim; Ni, Amy M.; Maunsell, John H. R.
2013-01-01
Neuronal assemblies often exhibit stimulus-induced rhythmic activity in the gamma range (30–80 Hz), whose magnitude depends on the attentional load. This has led to the suggestion that gamma rhythms form dynamic communication channels across cortical areas processing the features of behaviorally relevant stimuli. Recently, attention has been linked to a normalization mechanism, in which the response of a neuron is suppressed (normalized) by the overall activity of a large pool of neighboring neurons. In this model, attention increases the excitatory drive received by the neuron, which in turn also increases the strength of normalization, thereby changing the balance of excitation and inhibition. Recent studies have shown that gamma power also depends on such excitatory–inhibitory interactions. Could modulation in gamma power during an attention task be a reflection of the changes in the underlying excitation–inhibition interactions? By manipulating the normalization strength independent of attentional load in macaque monkeys, we show that gamma power increases with increasing normalization, even when the attentional load is fixed. Further, manipulations of attention that increase normalization increase gamma power, even when they decrease the firing rate. Thus, gamma rhythms could be a reflection of changes in the relative strengths of excitation and normalization rather than playing a functional role in communication or control. PMID:23393427
Hydraulic properties of 3D rough-walled fractures during shearing: An experimental study
NASA Astrophysics Data System (ADS)
Yin, Qian; Ma, Guowei; Jing, Hongwen; Wang, Huidong; Su, Haijian; Wang, Yingchao; Liu, Richeng
2017-12-01
This study experimentally analyzed the influence of shear processes on nonlinear flow behavior through 3D rough-walled rock fractures. A high-precision apparatus was developed to perform stress-dependent fluid flow tests of fractured rocks. Then, water flow tests on rough-walled fractures with different mechanical displacements were conducted. At each shear level, the hydraulic pressure ranged from 0 to 0.6 MPa, and the normal load varied from 7 to 35 kN. The results show that (i) the relationship between the volumetric flow rate and hydraulic gradient of rough-walled fractures can be well fit using Forchheimer's law. Notably, both the linear and nonlinear coefficients in Forchheimer's law decrease during shearing; (ii) a sixth-order polynomial function is used to evaluate the transmissivity based on the Reynolds number of fractures during shearing. The transmissivity exhibits a decreasing trend as the Reynolds number increases and an increasing trend as the shear displacement increases; (iii) the critical hydraulic gradient, critical Reynolds number and equivalent hydraulic aperture of the rock fractures all increase as the shear displacement increases. When the shear displacement varies from 0 to 15 mm, the critical hydraulic gradient ranges from 0.3 to 2.2 for a normal load of 7 kN and increases to 1.8-8.6 for a normal load of 35 kN; and (iv) the Forchheimer law results are evaluated by plotting the normalized transmissivity of the fractures during shearing against the Reynolds number. An increase in the normal load shifts the fitted curves downward. Additionally, the Forchheimer coefficient β decreases with the shear displacement but increases with the applied normal load.
Folman, Y; Wosk, J; Voloshin, A; Liberty, S
1986-01-01
The cyclic impacts induced by heel strike when walking were studied using both a high-resonance-frequency force plate and a low-mass skin-mounted accelerometer. The data were computer analyzed. The results showed that during normal human walking, the locomotor system is subjected to repetitive impact loads at heel strike, lasting about 5 ms and consisting of frequency spectra up to and above 100 Hz. The natural shock-absorbing structures in the musculoskeletal system have viscoelastic time-dependent mechanical behavior, which is relatively ineffective in withstanding sudden impulsive loads. Degenerative joint diseases may thus be seen as a late clinical result of fatigue failure of the natural shock absorbers, submitted to deleterious impacts over a period of time.
NASA Technical Reports Server (NTRS)
Sargent, N. B.
1980-01-01
The steady state test results on a breadboard version of the General Electric Near Term Electric Vehicle (ETV-1) are discussed. The breadboard was built using exact duplicate vehicle propulsion system components with few exceptions. Full instrumentation was provided to measure individual component efficiencies. Tests were conducted on a 50 hp dynamometer in a road load simulator facility. Characterization of the propulsion system over the lower half of the speed-torque operating range has shown the system efficiency to be composed of a predominant motor loss plus a speed dependent transaxle loss. At the lower speeds with normal road loads the armature chopper loss is also a significant factor. At the conditions corresponding to a cycle for which the vehicle system was specifically designed, the efficiencies are near optimum.
Kose, Samet; Sayar, Kemal; Kalelioglu, Ulgen; Aydin, Nazan; Celikel, Feryal Cam; Gulec, Huseyin; Ak, Ismail; Kirpinar, Ismet; Cloninger, C Robert
2009-01-01
Cloninger's dimensional psychobiological model of personality accounts for both normal and abnormal variation in 2 major personality components: temperament and character. Here, we examined the psychometric properties of the Turkish version of the Temperament and Character Inventory (TCI) in a healthy Turkish population, obtaining normative data for the Turkish TCI. The study was conducted in healthy volunteers at both Karadeniz Technical University School of Medicine and Atatürk University School of Medicine (n = 683). The Turkish sample had significantly lower mean scores on Novelty Seeking and Reward Dependence and higher mean scores on Harm Avoidance than the American sample. The Turkish sample had significantly lower scores on Self-Directedness, Cooperativeness, and Self-Transcendence. Self-Directedness and Harm Avoidance, Cooperativeness and Reward Dependence, and Cooperativeness and Self-Directedness were intercorrelated. The Cronbach coeficients were between 0.60 and 0.85 on temperament dimensions, and between 0.82 and 0.83 on character dimensions. The lowest Cronbach coefficients were found in Reward Dependence (0.60) and Persistence (0.62). A principal axis factor analysis with a 4-factor solution revealed the highest loadings on Novelty Seeking and Harm Avoidance and relatively weaker loadings on Reward Dependence and Persistence. A 3-factor solution for character subscales indicated the highest loadings on Cooperativeness and Self-Transcendence. The factorial structure was consistent with Cloninger's 7-factor model of personality, and test-retest indicated a good stability of scores over time. The reliability and factorial validity of the Turkish version of the TCI are therefore supported.
A Domain Decomposition Parallelization of the Fast Marching Method
NASA Technical Reports Server (NTRS)
Herrmann, M.
2003-01-01
In this paper, the first domain decomposition parallelization of the Fast Marching Method for level sets has been presented. Parallel speedup has been demonstrated in both the optimal and non-optimal domain decomposition case. The parallel performance of the proposed method is strongly dependent on load balancing separately the number of nodes on each side of the interface. A load imbalance of nodes on either side of the domain leads to an increase in communication and rollback operations. Furthermore, the amount of inter-domain communication can be reduced by aligning the inter-domain boundaries with the interface normal vectors. In the case of optimal load balancing and aligned inter-domain boundaries, the proposed parallel FMM algorithm is highly efficient, reaching efficiency factors of up to 0.98. Future work will focus on the extension of the proposed parallel algorithm to higher order accuracy. Also, to further enhance parallel performance, the coupling of the domain decomposition parallelization to the G(sub 0)-based parallelization will be investigated.
Ferrari, Raffaele; Ferrara, Michela; Alinani, Anwar; Sutton, Roger Brian; Famà, Francesco; Picco, Agnese; Rodriguez, Guido; Nobili, Flavio; Momeni, Parastoo
2015-01-01
Cohorts from a defined geographical area enable ad hoc genotype-phenotype correlation studies providing novel and unique insight into disease. We analysed genetic risk factors associated with early and late onset Alzheimer's disease (EOAD and LOAD) in a population from Liguria (northern Italy), as part of an ongoing longitudinal study. We screened 37 AD, 8 mild cognitive impairment (MCI), 3 AD and CVD (cerebrovascular disease), 3 MCI and CVD, 8 frontotemporal dementia (FTD) and 2 progressive supranuclear palsy (PSP) patients, and 28 normal controls (NCs).We sequenced PSEN1, PSEN2 and APP (EOAD risk factors), as well as MAPT, GRN and TARDBP for all cases and NCs, and analysed the APOE, CLU, CR1 and PICALM genotypes as well as the MAPT and ACE haplotypes (LOAD risk factors) for the AD (n = 37) and AD + MCI (n = 45) cases and NCs (n = 28).We identified variants in PSEN1, PSEN2 and TARDBP across a range of phenotypes (AD, AD and CVD, FTD and PSP), suggesting that screening of all known candidate genes of Alzheimer's and non-Alzheimer's forms of dementias in all dementia cases might be warranted. The analysis of the LOAD risk factors revealed no association with AD or AD + MCI status after Bonferroni correction. Lack of association with APOE is supported by previous studies in the Italian population. Our data also evidenced: 1) a potentially protective haplotype at the PSEN2 locus; 2) a nominal association with the GWAS-risk allele A for rs3818361 in CR1 and; 3) a threefold prevalence of AD in the female population compared to men.Our results will need to be further assessed and confirmed in larger cohorts from this area.
14 CFR 23.511 - Ground load; unsymmetrical loads on multiple-wheel units.
Code of Federal Regulations, 2010 CFR
2010-01-01
..., DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER... distribution, to the dual wheels and tires in each dual wheel landing gear unit. (c) Deflated tire loads. For...
NASA Technical Reports Server (NTRS)
Tanner, John A.
1996-01-01
A computational procedure is presented for the solution of frictional contact problems for aircraft tires. A Space Shuttle nose-gear tire is modeled using a two-dimensional laminated anisotropic shell theory which includes the effects of variations in material and geometric parameters, transverse-shear deformation, and geometric nonlinearities. Contact conditions are incorporated into the formulation by using a perturbed Lagrangian approach with the fundamental unknowns consisting of the stress resultants, the generalized displacements, and the Lagrange multipliers associated with both contact and friction conditions. The contact-friction algorithm is based on a modified Coulomb friction law. A modified two-field, mixed-variational principle is used to obtain elemental arrays. This modification consists of augmenting the functional of that principle by two terms: the Lagrange multiplier vector associated with normal and tangential node contact-load intensities and a regularization term that is quadratic in the Lagrange multiplier vector. These capabilities and computational features are incorporated into an in-house computer code. Experimental measurements were taken to define the response of the Space Shuttle nose-gear tire to inflation-pressure loads and to inflation-pressure loads combined with normal static loads against a rigid flat plate. These experimental results describe the meridional growth of the tire cross section caused by inflation loading, the static load-deflection characteristics of the tire, the geometry of the tire footprint under static loading conditions, and the normal and tangential load-intensity distributions in the tire footprint for the various static vertical loading conditions. Numerical results were obtained for the Space Shuttle nose-gear tire subjected to inflation pressure loads and combined inflation pressure and contact loads against a rigid flat plate. The experimental measurements and the numerical results are compared.
NASA Technical Reports Server (NTRS)
Tanner, John A.
1996-01-01
A computational procedure is presented for the solution of frictional contact problems for aircraft tires. A Space Shuttle nose-gear tire is modeled using a two-dimensional laminated anisotropic shell theory which includes the effects of variations in material and geometric parameters, transverse-shear deformation, and geometric nonlinearities. Contact conditions are incorporated into the formulation by using a perturbed Lagrangian approach with the fundamental unknowns consisting of the stress resultants, the generalized displacements, and the Lagrange multipliers associated with both contact and friction conditions. The contact-friction algorithm is based on a modified Coulomb friction law. A modified two-field, mixed-variational principle is used to obtain elemental arrays. This modification consists of augmenting the functional of that principle by two terms: the Lagrange multiplier vector associated with normal and tangential node contact-load intensities and a regularization term that is quadratic in the Lagrange multiplier vector. These capabilities and computational features are incorporated into an in-house computer code. Experimental measurements were taken to define the response of the Space Shuttle nose-gear tire to inflation-pressure loads and to inflation-pressure loads combined with normal static loads against a rigid flat plate. These experimental results describe the meridional growth of the tire cross section caused by inflation loading, the static load-deflection characteristics of the tire, the geometry of the tire footprint under static loading conditions, and the normal and tangential load-intensity distributions in the tire footprint for the various static vertical-loading conditions. Numerical results were obtained for the Space Shuttle nose-gear tire subjected to inflation pressure loads and combined inflation pressure and contact loads against a rigid flat plate. The experimental measurements and the numerical results are compared.
14 CFR 23.473 - Ground load conditions and assumptions.
Code of Federal Regulations, 2010 CFR
2010-01-01
... vertical inertia load factor at the center of gravity of the airplane for the ground load conditions... through the center of gravity. The ground reaction load factor may be equal to the inertia load factor..., these tests must be made under § 23.723(a). (g) No inertia load factor used for design purposes may be...
14 CFR 23.473 - Ground load conditions and assumptions.
Code of Federal Regulations, 2014 CFR
2014-01-01
... vertical inertia load factor at the center of gravity of the airplane for the ground load conditions... through the center of gravity. The ground reaction load factor may be equal to the inertia load factor..., these tests must be made under § 23.723(a). (g) No inertia load factor used for design purposes may be...
14 CFR 23.473 - Ground load conditions and assumptions.
Code of Federal Regulations, 2013 CFR
2013-01-01
... vertical inertia load factor at the center of gravity of the airplane for the ground load conditions... through the center of gravity. The ground reaction load factor may be equal to the inertia load factor..., these tests must be made under § 23.723(a). (g) No inertia load factor used for design purposes may be...
14 CFR 23.473 - Ground load conditions and assumptions.
Code of Federal Regulations, 2011 CFR
2011-01-01
... vertical inertia load factor at the center of gravity of the airplane for the ground load conditions... through the center of gravity. The ground reaction load factor may be equal to the inertia load factor..., these tests must be made under § 23.723(a). (g) No inertia load factor used for design purposes may be...
14 CFR 23.473 - Ground load conditions and assumptions.
Code of Federal Regulations, 2012 CFR
2012-01-01
... vertical inertia load factor at the center of gravity of the airplane for the ground load conditions... through the center of gravity. The ground reaction load factor may be equal to the inertia load factor..., these tests must be made under § 23.723(a). (g) No inertia load factor used for design purposes may be...
Lovibond, P F; Lovibond, S H
1995-03-01
The psychometric properties of the Depression Anxiety Stress Scales (DASS) were evaluated in a normal sample of N = 717 who were also administered the Beck Depression Inventory (BDI) and the Beck Anxiety Inventory (BAI). The DASS was shown to possess satisfactory psychometric properties, and the factor structure was substantiated both by exploratory and confirmatory factor analysis. In comparison to the BDI and BAI, the DASS scales showed greater separation in factor loadings. The DASS Anxiety scale correlated 0.81 with the BAI, and the DASS Depression scale correlated 0.74 with the BDI. Factor analyses suggested that the BDI differs from the DASS Depression scale primarily in that the BDI includes items such as weight loss, insomnia, somatic preoccupation and irritability, which fail to discriminate between depression and other affective states. The factor structure of the combined BDI and BAI items was virtually identical to that reported by Beck for a sample of diagnosed depressed and anxious patients, supporting the view that these clinical states are more severe expressions of the same states that may be discerned in normals. Implications of the results for the conceptualisation of depression, anxiety and tension/stress are considered, and the utility of the DASS scales in discriminating between these constructs is discussed.
14 CFR 23.527 - Hull and main float load factors.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Hull and main float load factors. 23.527... Water Loads § 23.527 Hull and main float load factors. (a) Water reaction load factors nw must be...=seaplane landing weight in pounds. (6) K1=empirical hull station weighing factor, in accordance with figure...
14 CFR 23.527 - Hull and main float load factors.
Code of Federal Regulations, 2011 CFR
2011-01-01
... Water Loads § 23.527 Hull and main float load factors. (a) Water reaction load factors nw must be... landing cases EC28SE91.005 (b) The following values are used: (1) nw=water reaction load factor (that is, the water reaction divided by seaplane weight). (2) C1=empirical seaplane operations factor equal to 0...
Stress Intensity Factors of Slanted Cracks in Bi-Material Plates
NASA Astrophysics Data System (ADS)
Ismail, Al Emran; Azhar Kamarudin, Kamarul; Nor, Nik Hisyamudin Muhd
2017-10-01
In this study, the stress intensity factors (SIF) of slanted cracks in bi-material plates subjected to mode I loading is numerically solved. Based on the literature survey, tremendous amount of research works are available studying the normal cracks in both similar and dissimilar plates. However, lack of SIF behavior for slanted cracks especially when it is embedded in bi-material plates. The slanted cracks are then modelled numerically using ANSYS finite element program. Two plates of different in mechanical properties are firmly bonded obliquely and then slanted edge cracks are introduced at the lower inclined edge. Isoparametric singular element is used to model the crack tip and the SIF is determined which is based on the domain integral method. Three mechanical mismatched and four slanted angles are used to model the cracks. According to the present results, the effects of mechanical mismatch on the SIF for normal cracks are not significant. However, it is played an important role when slanted angles are introduced. It is suggested that higher SIF can be obtained when the cracks are inclined comparing with the normal cracks. Consequently, accelerating the crack growth at the interface between two distinct materials.
14 CFR 23.521 - Water load conditions.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Water load conditions. 23.521 Section 23... AIRWORTHINESS STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Structure Water Loads § 23.521 Water load conditions. (a) The structure of seaplanes and amphibians must be designed for water...
14 CFR 27.681 - Limit load static tests.
Code of Federal Regulations, 2010 CFR
2010-01-01
... AIRWORTHINESS STANDARDS: NORMAL CATEGORY ROTORCRAFT Design and Construction Control Systems § 27.681 Limit load... which— (1) The direction of the test loads produces the most severe loading in the control system; and (2) Each fitting, pulley, and bracket used in attaching the system to the main structure is included...
14 CFR 23.681 - Limit load static tests.
Code of Federal Regulations, 2011 CFR
2011-01-01
... AIRWORTHINESS STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Design and Construction Control Systems § 23.681 Limit load static tests. (a) Compliance with the limit load requirements of this... loading in the control system; and (2) Each fitting, pulley, and bracket used in attaching the system to...
14 CFR 23.681 - Limit load static tests.
Code of Federal Regulations, 2010 CFR
2010-01-01
... AIRWORTHINESS STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Design and Construction Control Systems § 23.681 Limit load static tests. (a) Compliance with the limit load requirements of this... loading in the control system; and (2) Each fitting, pulley, and bracket used in attaching the system to...
14 CFR 23.681 - Limit load static tests.
Code of Federal Regulations, 2014 CFR
2014-01-01
... AIRWORTHINESS STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Design and Construction Control Systems § 23.681 Limit load static tests. (a) Compliance with the limit load requirements of this... loading in the control system; and (2) Each fitting, pulley, and bracket used in attaching the system to...
14 CFR 23.681 - Limit load static tests.
Code of Federal Regulations, 2012 CFR
2012-01-01
... AIRWORTHINESS STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Design and Construction Control Systems § 23.681 Limit load static tests. (a) Compliance with the limit load requirements of this... loading in the control system; and (2) Each fitting, pulley, and bracket used in attaching the system to...
14 CFR 23.681 - Limit load static tests.
Code of Federal Regulations, 2013 CFR
2013-01-01
... AIRWORTHINESS STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Design and Construction Control Systems § 23.681 Limit load static tests. (a) Compliance with the limit load requirements of this... loading in the control system; and (2) Each fitting, pulley, and bracket used in attaching the system to...
14 CFR 23.521 - Water load conditions.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Water load conditions. 23.521 Section 23... AIRWORTHINESS STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Structure Water Loads § 23.521 Water load conditions. (a) The structure of seaplanes and amphibians must be designed for water...
14 CFR 23.521 - Water load conditions.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Water load conditions. 23.521 Section 23... AIRWORTHINESS STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Structure Water Loads § 23.521 Water load conditions. (a) The structure of seaplanes and amphibians must be designed for water...
14 CFR 23.521 - Water load conditions.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Water load conditions. 23.521 Section 23... AIRWORTHINESS STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Structure Water Loads § 23.521 Water load conditions. (a) The structure of seaplanes and amphibians must be designed for water...
Kendler, K. S.; Myers, J.; Reichborn-Kjennerud, T.
2011-01-01
Objective To describe the structure of genetic and environmental risk factors for four dimensions of borderline personality disorder (BPD) and to understand the source of resemblance of these dimensions and normal personality. Method A web-based sample (n = 44,112 including 542 twin pairs) completed items from 4 scales of the Dimensional Assessment of Personality Pathology Basic Questionnaire and the Big Five Inventory. Results A one-factor common pathway model best fits the 4 BPD scales producing a highly heritable latent liability (heritability = 60%) and strong loadings on all 4 dimensions. Affective instability had the lowest trait-specific genetic loading, suggesting that it was a core feature of BPD. A complex pattern of genetic and environmental associations was found between the big five personality traits and BPD dimensions. The strongest genetic correlations with the BPD traits were generally seen for neuroticism (positive), followed by conscientiousness and agreeableness, both negative. Conclusion In the general population, these four BPD dimensions reflect one underlying highly heritable factor. The association between normative personality and dimensions of BPD is complex with high degrees of genetic correlation. PMID:21198457
Kendler, K S; Myers, J; Reichborn-Kjennerud, T
2011-05-01
To describe the structure of genetic and environmental risk factors for four dimensions of borderline personality disorder (BPD) and to understand the source of resemblance of these dimensions and normal personality. A web-based sample (n = 44,112 including 542 twin pairs) completed items from 4 scales of the Dimensional Assessment of Personality Pathology Basic Questionnaire and the Big Five Inventory. A one-factor common pathway model best fits the 4 BPD scales producing a highly heritable latent liability (heritability = 60%) and strong loadings on all 4 dimensions. Affective instability had the lowest trait-specific genetic loading, suggesting that it was a core feature of BPD. A complex pattern of genetic and environmental associations was found between the big five personality traits and BPD dimensions. The strongest genetic correlations with the BPD traits were generally seen for neuroticism (positive), followed by conscientiousness and agreeableness, both negative. In the general population, these four BPD dimensions reflect one underlying highly heritable factor. The association between normative personality and dimensions of BPD is complex with high degrees of genetic correlation. © 2010 John Wiley & Sons A/S.
Sliding contact fracture of dental ceramics: Principles and validation
Ren, Linlin; Zhang, Yu
2014-01-01
Ceramic prostheses are subject to sliding contact under normal and tangential loads. Accurate prediction of the onset of fracture at two contacting surfaces holds the key to greater long-term performance of these prostheses. In this study, building on stress analysis of Hertzian contact and considering fracture criteria for linear elastic materials, a constitutive fracture mechanics relation was developed to incorporate the critical fracture load with the contact geometry, coefficient of friction and material fracture toughness. Critical loads necessary to cause fracture under a sliding indenter were calculated from the constitutive equation, and compared with the loads predicted from elastic stress analysis in conjunction with measured critical load for frictionless normal contact—a semi-empirical approach. The major predictions of the models were calibrated with experimentally determined critical loads of current and future dental ceramics after contact with a rigid spherical slider. Experimental results conform with the trends predicted by the models. PMID:24632538
14 CFR 31.23 - Flight load factor.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Flight load factor. 31.23 Section 31.23... STANDARDS: MANNED FREE BALLOONS Strength Requirements § 31.23 Flight load factor. In determining limit load, the limit flight load factor must be at least 1.4. ...
14 CFR 31.23 - Flight load factor.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Flight load factor. 31.23 Section 31.23... STANDARDS: MANNED FREE BALLOONS Strength Requirements § 31.23 Flight load factor. In determining limit load, the limit flight load factor must be at least 1.4. ...
14 CFR 31.23 - Flight load factor.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Flight load factor. 31.23 Section 31.23... STANDARDS: MANNED FREE BALLOONS Strength Requirements § 31.23 Flight load factor. In determining limit load, the limit flight load factor must be at least 1.4. ...
Lefevre, Jonas; Hankins, Catherine; Money, Deborah; Rachlis, Anita; Pourreaux, Karina; Coutlée, François
2004-01-01
Human papillomavirus type 16 (HPV-16) viral load in cervicovaginal lavage samples collected from 66 human immunodeficiency virus-seropositive women was inversely correlated with blood CD4 count (P = 0.002). HPV-16 viral load was 81-fold higher in women with cervical smears suggestive of high-grade lesions (median, 4,425,883 copies/μg of DNA) than in women with normal smears (median, 54,576), controlling for age (P = 0.006). PMID:15131192
Microbial Dysbiosis Is Associated with Human Breast Cancer
Xuan, Caiyun; Shamonki, Jaime M.; Chung, Alice; DiNome, Maggie L.; Chung, Maureen; Sieling, Peter A.; Lee, Delphine J.
2014-01-01
Breast cancer affects one in eight women in their lifetime. Though diet, age and genetic predisposition are established risk factors, the majority of breast cancers have unknown etiology. The human microbiota refers to the collection of microbes inhabiting the human body. Imbalance in microbial communities, or microbial dysbiosis, has been implicated in various human diseases including obesity, diabetes, and colon cancer. Therefore, we investigated the potential role of microbiota in breast cancer by next-generation sequencing using breast tumor tissue and paired normal adjacent tissue from the same patient. In a qualitative survey of the breast microbiota DNA, we found that the bacterium Methylobacterium radiotolerans is relatively enriched in tumor tissue, while the bacterium Sphingomonas yanoikuyae is relatively enriched in paired normal tissue. The relative abundances of these two bacterial species were inversely correlated in paired normal breast tissue but not in tumor tissue, indicating that dysbiosis is associated with breast cancer. Furthermore, the total bacterial DNA load was reduced in tumor versus paired normal and healthy breast tissue as determined by quantitative PCR. Interestingly, bacterial DNA load correlated inversely with advanced disease, a finding that could have broad implications in diagnosis and staging of breast cancer. Lastly, we observed lower basal levels of antibacterial response gene expression in tumor versus healthy breast tissue. Taken together, these data indicate that microbial DNA is present in the breast and that bacteria or their components may influence the local immune microenvironment. Our findings suggest a previously unrecognized link between dysbiosis and breast cancer which has potential diagnostic and therapeutic implications. PMID:24421902
Guo, Yi; Keller, Jonathan
2017-11-10
Many wind turbine gearboxes require repair or replacement well before reaching the end of their design life. The most common failure is bearing axial cracks, commonly called white etching cracks (WECs), which typically occur in the inner raceways of the high-speed parallel-stage rolling element bearings. Although the root causes of WECs are debated, one theory is that they are related to routine dynamic operating conditions and occasional transient events prevalent in wind turbines that can result in high bearing stress and sliding of the rolling elements. Here, this paper examined wind turbine gearbox high-speed shaft bearing loads and stresses throughmore » modeling and full-scale dynamometer testing. Bearing outer race loads were directly measured and predicted using a variety of modeling tools in normal operations, misaligned conditions, and transient events particularly prone to bearing sliding. Test data and models of bearing loads were well correlated. Neither operational misalignment due to rotor moments nor static generator misalignment affected the bearing loads when compared with pure-torque conditions. Thus, it is not likely that generator misalignment is a causal factor of WECs. In contrast, during transient events, the bearings experienced alternating periods of high stress, torque reversals, and loads under the minimum requisite at high rotating speeds while showing indications of sliding, all of which could be related to the formation of WECs.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Guo, Yi; Keller, Jonathan
Many wind turbine gearboxes require repair or replacement well before reaching the end of their design life. The most common failure is bearing axial cracks, commonly called white etching cracks (WECs), which typically occur in the inner raceways of the high-speed parallel-stage rolling element bearings. Although the root causes of WECs are debated, one theory is that they are related to routine dynamic operating conditions and occasional transient events prevalent in wind turbines that can result in high bearing stress and sliding of the rolling elements. Here, this paper examined wind turbine gearbox high-speed shaft bearing loads and stresses throughmore » modeling and full-scale dynamometer testing. Bearing outer race loads were directly measured and predicted using a variety of modeling tools in normal operations, misaligned conditions, and transient events particularly prone to bearing sliding. Test data and models of bearing loads were well correlated. Neither operational misalignment due to rotor moments nor static generator misalignment affected the bearing loads when compared with pure-torque conditions. Thus, it is not likely that generator misalignment is a causal factor of WECs. In contrast, during transient events, the bearings experienced alternating periods of high stress, torque reversals, and loads under the minimum requisite at high rotating speeds while showing indications of sliding, all of which could be related to the formation of WECs.« less
Meyer, Andrew J; D'Lima, Darryl D; Besier, Thor F; Lloyd, David G; Colwell, Clifford W; Fregly, Benjamin J
2013-06-01
Mechanical loading is believed to be a critical factor in the development and treatment of knee osteoarthritis. However, the contact forces to which the knee articular surfaces are subjected during daily activities cannot be measured clinically. Thus, the ability to predict internal knee contact forces accurately using external measures (i.e., external knee loads and muscle electromyographic [EMG] signals) would be clinically valuable. We quantified how well external knee load and EMG measures predict internal knee contact forces during gait. A single subject with a force-measuring tibial prosthesis and post-operative valgus alignment performed four gait patterns (normal, medial thrust, walking pole, and trunk sway) to induce a wide range of external and internal knee joint loads. Linear regression analyses were performed to assess how much of the variability in internal contact forces was accounted for by variability in the external measures. Though the different gait patterns successfully induced significant changes in the external and internal quantities, changes in external measures were generally weak indicators of changes in total, medial, and lateral contact force. Our results suggest that when total contact force may be changing, caution should be exercised when inferring changes in knee contact forces based on observed changes in external knee load and EMG measures. Advances in musculoskeletal modeling methods may be needed for accurate estimation of in vivo knee contact forces. Copyright © 2012 Orthopaedic Research Society.
Changing Regulations of COD Pollution Load of Weihe River Watershed above TongGuan Section, China
NASA Astrophysics Data System (ADS)
Zhu, Lei; Liu, WanQing
2018-02-01
TongGuan Section of Weihe River Watershed is a provincial section between Shaanxi Province and Henan Province, China. Weihe River Watershed above TongGuan Section is taken as the research objective in this paper and COD is chosen as the water quality parameter. According to the discharge characteristics of point source pollutions and non-point source pollutions, a method—characteristic section load (CSLD) method is suggested and point and non-point source pollution loads of Weihe River Watershed above TongGuan Section are calculated in the rainy, normal and dry season in 2013. The results show that the monthly point source pollution loads of Weihe River Watershed above TongGuan Section discharge stably and the monthly non-point source pollution loads of Weihe River Watershed above TongGuan Section change greatly and the non-point source pollution load proportions of total pollution load of COD decrease in the rainy, wet and normal period in turn.
NASA Astrophysics Data System (ADS)
Zhu, Lei; Song, JinXi; Liu, WanQing
2017-12-01
Huaxian Section is the last hydrological and water quality monitoring section of Weihe River Watershed. Weihe River Watershed above Huaxian Section is taken as the research objective in this paper and COD is chosen as the water quality parameter. According to the discharge characteristics of point source pollutions and non-point source pollutions, a new method to estimate pollution loads—characteristic section load(CSLD) method is suggested and point source pollution and non-point source pollution loads of Weihe River Watershed above Huaxian Section are calculated in the rainy, normal and dry season in the year 2007. The results show that the monthly point source pollution loads of Weihe River Watershed above Huaxian Section discharge stably and the monthly non-point source pollution loads of Weihe River Watershed above Huaxian Section change greatly and the non-point source pollution load proportions of total pollution load of COD decrease in the normal, rainy and wet period in turn.
Calculating NH3-N pollution load of wei river watershed above Huaxian section using CSLD method
NASA Astrophysics Data System (ADS)
Zhu, Lei; Song, JinXi; Liu, WanQing
2018-02-01
Huaxian Section is the last hydrological and water quality monitoring section of Weihe River Watershed. So it is taken as the research objective in this paper and NH3-N is chosen as the water quality parameter. According to the discharge characteristics of point source pollutions and non-point source pollutions, a new method to estimate pollution loads—characteristic section load (CSLD)method is suggested and point source pollution and non-point source pollution loads of Weihe River Watershed above Huaxian Section are calculated in the rainy, normal and dry season in the year 2007. The results show that the monthly point source pollution loads of Weihe River Watershed above Huaxian Section discharge stably and the monthly non-point source pollution loads of Weihe River Watershed above Huaxian Section change greatly. The non-point source pollution load proportions of total pollution load of NH3-N decrease in the normal, rainy and wet period in turn.
[Homocysteine after a methionine load in healthy subjects with adequate B-vitamin status].
López-Alarcón, Mardia; Chávez-Negrete, Adolfo; Montalvo-Velarde, Irene; Maldonado-Hernández, Jorge; Vital-Reyes, Víctor Saúl
2011-01-01
Plasma homocysteine (Hcy) determination at 6-8 h after an oral methionine load (OML) allows for identification of some, but not all, individuals at risk to develop cardiovascular disease. It is probable that in some cases the Hcy increases occur later, or it elevates between normal ranges but in a sustained manner. However, the entire Hcy response curve has not been described. We undertook this study to determine Hcy concentrations from baseline to 24- and 48-h after an OML in non-B-vitamin deficient adult subjects with other risk factors for high levels of Hcy such as smoking and overweight. In a cross-over, clinical design, Hcy concentrations were determined at 2-h intervals throughout 12 h and at 24 h and 48 h after an OML (0.1 g/kg). Hcy and vitamin B6 (VB6) concentrations were measured by high-performance liquid chromatography (HPLC). Folic acid (FA) and vitamin B12 (VB12) were measured by radioimmunoassay (RIA). Statistical analysis included delta values and areas under the curve. Student t-test and repeated measurement analyses were conducted to control for confounders. Twenty-nine subjects with adequate Hcy, FA, VB6 and VB12 status were included. The maximum Hcy concentration occurred 8 h after the load and returned to baseline concentrations after 24 h. All subjects presented Hcy after the load within normal ranges, but smoking and overweight synergistically influenced the response to the challenge, producing a sustained elevation after the dose. Hcy concentrations after an OML remained above baseline for at least 24 h. Smoking and overweight affected the response to the methionine challenge.
Study of fatigue behavior of longitudinal welded pipes
NASA Astrophysics Data System (ADS)
Simion, P.; Dia, V.; Istrate, B.; Hrituleac, G.; Hrituleac, I.; Munteanu, C.
2016-08-01
During transport and storage of the various fluids, welded pipes are subjected to cyclic loading due to pressure fluctuations that often exceed the prescribed values for normal operation. These cyclic loading can significantly reduce the life of the pipes; as a result the design should be based on the fatigue strength not only on static resistance. In general the fatigue strength of pipes is dependent by strength, pipe geometry and surface quality. In case of the electric longitudinal welded pipes, the fatigue strength is significantly limited by concentration of residual stress and the size of existing defects in the weld seam. This paper presents the fatigue behaviour of the electric welded pipes by high frequency, under conditions that simulate real operating conditions pipes. Fatigue testing was performed on welded pipes made of micro alloyed carbon steels. Some of these pipes were previously subjected to a heat treatment of normalization, in order to also determine the influence of heat treatment on the fatigue strength of welded pipes. To determine and correlate the different factors affecting the fatigue strength, welded pipes were also subjected to various tests: tensile tests, impact tests, measurement of micro hardness, microstructural analysis by optical microscopy and scanning electron microscopy.
Kawano, Sandy M; Economy, D Ross; Kennedy, Marian S; Dean, Delphine; Blob, Richard W
2016-02-01
Locomotion imposes some of the highest loads upon the skeleton, and diverse bone designs have evolved to withstand these demands. Excessive loads can fatally injure organisms; however, bones have a margin of extra protection, called a 'safety factor' (SF), to accommodate loads that are higher than normal. The extent to which SFs might vary amongst an animal's limb bones is unclear. If the limbs are likened to a chain composed of bones as 'links', then similar SFs might be expected for all limb bones because failure of the system would be determined by the weakest link, and extra protection in other links could waste energetic resources. However, Alexander proposed that a 'mixed-chain' of SFs might be found amongst bones if: (1) their energetic costs differ, (2) some elements face variable demands, or (3) SFs are generally high. To test whether such conditions contribute to diversity in limb bone SFs, we compared the biomechanical properties and locomotor loading of the humerus and femur in the tiger salamander (Ambystoma tigrinum). Despite high SFs in salamanders and similar sizes of the humerus and femur that would suggest similar energetic costs, the humerus had lower bone stresses, higher mechanical hardness and larger SFs. SFs were greatest in the anatomical regions where yield stresses were highest in the humerus and lowest in the femur. Such intraspecific variation between and within bones may relate to their different biomechanical functions, providing insight into the emergence of novel locomotor capabilities during the invasion of land by tetrapods. © 2016. Published by The Company of Biologists Ltd.
Temperature effects on ash physical and chemical properties. A laboratory study.
NASA Astrophysics Data System (ADS)
Pereira, Paulo; Úbeda, Xavier; Martin, Deborah
2010-05-01
Fire temperatures have different impacts on ash physical and chemical properties that depend mainly of the specie affected and time of exposition. In a real prescribed or wildland fire, the temperatures produce ash with different characteristics. Know the impacts of a specific temperature or a gradient on a certain element and specie is very difficult in real fires, especially in wildland fires, where temperatures achieve higher values and the burning conditions are not controlled. Hence, laboratory studies revealed to be an excellent methodology to understand the effects of fire temperatures in ash physical and chemical. The aim of this study is study the effects of a temperature gradient (150, 200, 250, 300, 350, 400, 450, 500 and 550°C) on ash physical and chemical properties. For this study we collected litter of Quercus suber, Pinus pinea and Pinus pinaster in a plot located in Portugal. The selected species are the most common in the ecosystem. We submitted samples to the mentioned temperatures throughout a time of two hours and we analysed several parameters, namely, Loss on Ignition (LOI%), ash colour - through the Croma Value (CV) observed in Munsell color chart - CaCO3, Total Nitrogen (TN), Total Carbon (TC), C/N ratio, ash pH, Electrical Conductivity (EC), extractable Calcium (Ca2+), Magnesium (Mg2+), Sodium (Na+), Potassium (K+), Aluminium (Al3+), Manganese (Mn2+), Iron (Fe2+), Zinc (Zn2+), Total Phosphorous (TP), Sulphur (S) and Silica (SiO2). Since we considered many elements, in order to obtain a better explanation of all dataset, we applied a Factorial Analysis (FA), based on the correlation matrix and the Factors were extracted according to the Principle Components method. To obtain a better relation between the variables with a specific Factor we rotated the matrix according to the VARIMAX NORMALIZED method. FA identified 5 Factors that explained a total of 95% of the variance. We retained in each Factor the variables that presented an eigenvalue >0.7. Factor 1 explained the majority of the variance (60.05%). LOI(%), CV, CaCO3, pH, Na+, K+, S (these last tree elements only in both Pinus) and SiO2, showed positive loadings. Inversely, TC, C/N ratio, Al3+, Fe2+ (these last tree elements for Quercus suber and Pinus pinaster ash) and Mn2+ (In the case of Quercus suber) presented negative loadings. Factor 2 explained 19.89% of the variance and showed higher loadings in TN, Ca2+ and Mg2+ (in the case of the ions only in both Pinus). Factor 3 explains only 6.69% of the variance and we identified higher loadings in Mg2+, Na+ and K+ of Quercus suber. Factor 4 explains less then the last Factor, only 4.60% of the variance and presented negative loadings above -0.7 in TP of Quercus suber and Pinus pinea. Factor 5 explained 3.93% of the variance, less than all other Factors and showed in Al3+, Mn2+ and Zn2+ of Pinus pinea and in the case of the last element, also in Pinus pinaster. The observation of the scores matrix allowed us to understand the major concentration of these elements according the temperature of exposition. Hence, the elements that showed higher positive loadings in Factor 1, have a major concentration at 450, 500 and 550°C, and the ones with higher negative loadings presented higher concentration at 200 and 250°C. The nutrients that presented higher positive loadings in Factor 2 have higher concentrations at 400°C. The elements with higher positive loadings in Factor 3 have bigger amounts in the ash slurries produced at 350°C and the ones with higher negative loadings in the Factor 4 showed greater concentrations in the ash produced at 300°C. The elements with higher negative loadings in the Factor 5 showed higher amounts in the ash created at 150°C of exposition. The results obtained showed that nutrients concentration is a function of the burned specie and temperature reached in the considered exposure time. Micronutrients and TC and C/N showed higher values at lower temperatures, TN, Ca2+, Mg2+ and TP at temperatures between 300-400°C. The other variables in study have major concentrations at temperatures higher than 450°C. Some differences between species can be identified and this is a result of the different litter vulnerabilities to the same temperature, producing diverse fire severities. This and other reasons for this behaviour will be discussed in the communication.
14 CFR 25.527 - Hull and main float load factors.
Code of Federal Regulations, 2011 CFR
2011-01-01
... float load factors. (a) Water reaction load factors n W must be computed in the following manner: (1... following values are used: (1) n W=water reaction load factor (that is, the water reaction divided by...
Continuous fluidized-bed contactor with recycle of sorbent
Scott, Charles D.; Petersen, James N.; Davison, Brian H.
1996-01-01
A continuous fluidized-bed contactor containing sorbent particles is used to remove solutes from liquid solvents. As the sorbent particles, for example gel beads, sorb the solute, for example metal ion species, the sorbent particles tend to decrease in diameter. These smaller loaded sorbent particles rise to the top of the contactor, as larger sorbent particles remain at the bottom of the contactor as a result of normal hydraulic forces. The smaller loaded sorbent particles are then recovered, regenerated, and reintroduced into the contactor. Alternatively, the loaded sorbent particles may also slightly increase in diameter, or exhibit no change in diameter but an increase in density. As a result of normal hydraulic forces the larger loaded sorbent particles fall to the bottom of the contactor. The larger loaded sorbent particles are then recovered, regenerated, and reintroduced into the contactor.
Continuous fluidized-bed contactor with recycle of sorbent
Scott, C.D.; Petersen, J.N.; Davison, B.H.
1996-07-09
A continuous fluidized-bed contactor containing sorbent particles is used to remove solutes from liquid solvents. As the sorbent particles, for example gel beads, sorb the solute, for example metal ion species, the sorbent particles tend to decrease in diameter. These smaller loaded sorbent particles rise to the top of the contactor, and larger sorbent particles remain at the bottom of the contactor as a result of normal hydraulic forces. The smaller loaded sorbent particles are then recovered, regenerated, and reintroduced into the contactor. Alternatively, the loaded sorbent particles may also slightly increase in diameter, or exhibit no change in diameter but an increase in density. As a result of normal hydraulic forces the larger loaded sorbent particles fall to the bottom of the contactor. The larger loaded sorbent particles are then recovered, regenerated, and reintroduced into the contactor. 8 figs.
Contact area of rough spheres: Large scale simulations and simple scaling laws
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pastewka, Lars, E-mail: lars.pastewka@kit.edu; Department of Physics and Astronomy, Johns Hopkins University, 3400 North Charles Street, Baltimore, Maryland 21218; Robbins, Mark O., E-mail: mr@pha.jhu.edu
2016-05-30
We use molecular simulations to study the nonadhesive and adhesive atomic-scale contact of rough spheres with radii ranging from nanometers to micrometers over more than ten orders of magnitude in applied normal load. At the lowest loads, the interfacial mechanics is governed by the contact mechanics of the first asperity that touches. The dependence of contact area on normal force becomes linear at intermediate loads and crosses over to Hertzian at the largest loads. By combining theories for the limiting cases of nominally flat rough surfaces and smooth spheres, we provide parameter-free analytical expressions for contact area over the wholemore » range of loads. Our results establish a range of validity for common approximations that neglect curvature or roughness in modeling objects on scales from atomic force microscope tips to ball bearings.« less
Stewart analysis of apparently normal acid-base state in the critically ill.
Moviat, Miriam; van den Boogaard, Mark; Intven, Femke; van der Voort, Peter; van der Hoeven, Hans; Pickkers, Peter
2013-12-01
This study aimed to describe Stewart parameters in critically ill patients with an apparently normal acid-base state and to determine the incidence of mixed metabolic acid-base disorders in these patients. We conducted a prospective, observational multicenter study of 312 consecutive Dutch intensive care unit patients with normal pH (7.35 ≤ pH ≤ 7.45) on days 3 to 5. Apparent (SIDa) and effective strong ion difference (SIDe) and strong ion gap (SIG) were calculated from 3 consecutive arterial blood samples. Multivariate linear regression analysis was performed to analyze factors potentially associated with levels of SIDa and SIG. A total of 137 patients (44%) were identified with an apparently normal acid-base state (normal pH and -2 < base excess < 2 and 35 < PaCO2 < 45 mm Hg). In this group, SIDa values were 36.6 ± 3.6 mEq/L, resulting from hyperchloremia (109 ± 4.6 mEq/L, sodium-chloride difference 30.0 ± 3.6 mEq/L); SIDe values were 33.5 ± 2.3 mEq/L, resulting from hypoalbuminemia (24.0 ± 6.2 g/L); and SIG values were 3.1 ± 3.1 mEq/L. During admission, base excess increased secondary to a decrease in SIG levels and, subsequently, an increase in SIDa levels. Levels of SIDa were associated with positive cation load, chloride load, and admission SIDa (multivariate r(2) = 0.40, P < .001). Levels of SIG were associated with kidney function, sepsis, and SIG levels at intensive care unit admission (multivariate r(2) = 0.28, P < .001). Intensive care unit patients with an apparently normal acid-base state have an underlying mixed metabolic acid-base disorder characterized by acidifying effects of a low SIDa (caused by hyperchloremia) and high SIG combined with the alkalinizing effect of hypoalbuminemia. © 2013.
14 CFR 23.341 - Gust loads factors.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Gust loads factors. 23.341 Section 23.341... loads factors. (a) Each airplane must be designed to withstand loads on each lifting surface resulting... criteria of § 23.333(c). (c) In the absence of a more rational analysis, the gust load factors must be...
Cluster analysis of cognitive performance in elderly and demented subjects.
Giaquinto, S; Nolfe, G; Calvani, M
1985-06-01
48 elderly normals, 14 demented subjects and 76 young controls were tested for basic cognitive functions. All the tests were quantified and could therefore be subjected to statistical analysis. The results show a difference in the speed of information processing and in memory load between the young controls and elderly normals but the age groups differed in quantitative terms only. Cluster analysis showed that the elderly and the demented formed two distinctly separate groups at the qualitative level, the basic cognitive processes being damaged in the demented group. Age thus appears to be only a risk factor for dementia and not its cause. It is concluded that batteries based on precise and measurable tasks are the most appropriate not only for the study of dementia but for rehabilitation purposes too.
Kubarych, Thomas S.; Kendler, Kenneth S.; Aggen, Steven H.; Estabrook, Ryne; Edwards, Alexis C.; Clark, Shaunna L.; Martin, Nicholas G.; Hickie, Ian B.; Neale, Michael C.; Gillespie, Nathan A.
2014-01-01
Accumulating evidence suggests that the Diagnostic and Statistical Manual of Mental Disorders (DSM) diagnostic criteria for cannabis abuse and dependence are best represented by a single underlying factor. However, it remains possible that models with additional factors, or latent class models or hybrid models, may better explain the data. Using structured interviews, 626 adult male and female twins provided complete data on symptoms of cannabis abuse and dependence, plus a craving criterion. We compared latent factor analysis, latent class analysis, and factor mixture modeling using normal theory marginal maximum likelihood for ordinal data. Our aim was to derive a parsimonious, best-fitting cannabis use disorder (CUD) phenotype based on DSM-IV criteria and determine whether DSM-5 craving loads onto a general factor. When compared with latent class and mixture models, factor models provided a better fit to the data. When conditioned on initiation and cannabis use, the association between criteria for abuse, dependence, withdrawal, and craving were best explained by two correlated latent factors for males and females: a general risk factor to CUD and a factor capturing the symptoms of social and occupational impairment as a consequence of frequent use. Secondary analyses revealed a modest increase in the prevalence of DSM-5 CUD compared with DSM-IV cannabis abuse or dependence. It is concluded that, in addition to a general factor with loadings on cannabis use and symptoms of abuse, dependence, withdrawal, and craving, a second clinically relevant factor defined by features of social and occupational impairment was also found for frequent cannabis use. PMID:24588857
A Baseline Load Schedule for the Manual Calibration of a Force Balance
NASA Technical Reports Server (NTRS)
Ulbrich, N.; Gisler, R.
2013-01-01
A baseline load schedule for the manual calibration of a force balance was developed that takes current capabilities at the NASA Ames Balance Calibration Laboratory into account. The load schedule consists of 18 load series with a total of 194 data points. It was designed to satisfy six requirements: (i) positive and negative loadings should be applied for each load component; (ii) at least three loadings should be applied between 0 % and 100 % load capacity; (iii) normal and side force loadings should be applied at the forward gage location, the aft gage location, and the balance moment center; (iv) the balance should be used in UP and DOWN orientation to get axial force loadings; (v) the constant normal and side force approaches should be used to get the rolling moment loadings; (vi) rolling moment loadings should be obtained for 0, 90, 180, and 270 degrees balance orientation. Three different approaches are also reviewed that may be used to independently estimate the natural zeros of the balance. These three approaches provide gage output differences that may be used to estimate the weight of both the metric and non-metric part of the balance. Manual calibration data of NASA s MK29A balance and machine calibration data of NASA s MC60D balance are used to illustrate and evaluate different aspects of the proposed baseline load schedule design.
Calibration of LRFR live load factors using weigh-in-motion data.
DOT National Transportation Integrated Search
2006-06-01
The Load and Resistance Factor Rating (LRFR) code for load rating bridges is based on factors calibrated from structural : load and resistance statistics to achieve a more uniform level of reliability for all bridges. The liveload factors in the : LR...
14 CFR 27.427 - Unsymmetrical loads.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Unsymmetrical loads. 27.427 Section 27.427 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: NORMAL CATEGORY ROTORCRAFT Strength Requirements Control Surface and System Loads § 27.427...
Structural evaluation of the 2736Z Building for seismic loads
DOE Office of Scientific and Technical Information (OSTI.GOV)
Giller, R.A.
The 2736Z building structure is evaluated for high-hazard loads. The 2736Z building is analyzed herein for normal and seismic loads and is found to successfully meet the guidelines of UCRL-15910 along with the related codes requirements.
14 CFR 25.1531 - Maneuvering flight load factors.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Maneuvering flight load factors. 25.1531 Section 25.1531 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION... Operating Limitations § 25.1531 Maneuvering flight load factors. Load factor limitations, not exceeding the...
14 CFR 25.1531 - Maneuvering flight load factors.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Maneuvering flight load factors. 25.1531 Section 25.1531 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION... Operating Limitations § 25.1531 Maneuvering flight load factors. Load factor limitations, not exceeding the...
Load and Time Dependence of Interfacial Chemical Bond-Induced Friction at the Nanoscale.
Tian, Kaiwen; Gosvami, Nitya N; Goldsby, David L; Liu, Yun; Szlufarska, Izabela; Carpick, Robert W
2017-02-17
Rate and state friction (RSF) laws are widely used empirical relationships that describe the macroscale frictional behavior of a broad range of materials, including rocks found in the seismogenic zone of Earth's crust. A fundamental aspect of the RSF laws is frictional "aging," where friction increases with the time of stationary contact due to asperity creep and/or interfacial strengthening. Recent atomic force microscope (AFM) experiments and simulations found that nanoscale silica contacts exhibit aging due to the progressive formation of interfacial chemical bonds. The role of normal load (and, thus, normal stress) on this interfacial chemical bond-induced (ICBI) friction is predicted to be significant but has not been examined experimentally. Here, we show using AFM that, for nanoscale ICBI friction of silica-silica interfaces, aging (the difference between the maximum static friction and the kinetic friction) increases approximately linearly with the product of the normal load and the log of the hold time. This behavior is attributed to the approximately linear dependence of the contact area on the load in the positive load regime before significant wear occurs, as inferred from sliding friction measurements. This implies that the average pressure, and thus the average bond formation rate, is load independent within the accessible load range. We also consider a more accurate nonlinear model for the contact area, from which we extract the activation volume and the average stress-free energy barrier to the aging process. Our work provides an approach for studying the load and time dependence of contact aging at the nanoscale and further establishes RSF laws for nanoscale asperity contacts.
Load and Time Dependence of Interfacial Chemical Bond-Induced Friction at the Nanoscale
NASA Astrophysics Data System (ADS)
Tian, Kaiwen; Gosvami, Nitya N.; Goldsby, David L.; Liu, Yun; Szlufarska, Izabela; Carpick, Robert W.
2017-02-01
Rate and state friction (RSF) laws are widely used empirical relationships that describe the macroscale frictional behavior of a broad range of materials, including rocks found in the seismogenic zone of Earth's crust. A fundamental aspect of the RSF laws is frictional "aging," where friction increases with the time of stationary contact due to asperity creep and/or interfacial strengthening. Recent atomic force microscope (AFM) experiments and simulations found that nanoscale silica contacts exhibit aging due to the progressive formation of interfacial chemical bonds. The role of normal load (and, thus, normal stress) on this interfacial chemical bond-induced (ICBI) friction is predicted to be significant but has not been examined experimentally. Here, we show using AFM that, for nanoscale ICBI friction of silica-silica interfaces, aging (the difference between the maximum static friction and the kinetic friction) increases approximately linearly with the product of the normal load and the log of the hold time. This behavior is attributed to the approximately linear dependence of the contact area on the load in the positive load regime before significant wear occurs, as inferred from sliding friction measurements. This implies that the average pressure, and thus the average bond formation rate, is load independent within the accessible load range. We also consider a more accurate nonlinear model for the contact area, from which we extract the activation volume and the average stress-free energy barrier to the aging process. Our work provides an approach for studying the load and time dependence of contact aging at the nanoscale and further establishes RSF laws for nanoscale asperity contacts.
Wilson, D A; Keegan, K G; Carson, W L
1999-01-01
This study compared the mechanical properties of the normal intact suspensory apparatus and two methods of fixation for repair of transverse, midbody fractures of the proximal sesamoid bones of adult horses: transfixation wiring (TW) and screws placed in lag fashion (LS). An in vitro, paired study using equine cadaver limbs mounted in a loading apparatus was used to test the mechanical properties of TW and LS. Seventeen paired (13 repaired, 4 normal) equine cadaver limbs consisting of the suspensory apparatus third metacarpal bone, and first and second phalanges. The two methods of repair and normal intact specimens were evaluated in single cycle-to-failure loading. Yield failure was defined to occur at the first notable discontinuity (>50 N) in the load-displacement curve, the first visible failure as evident on the videotape, or a change in the slope of the moment-fetlock angle curve. Ultimate failure was defined to occur at the highest load resisted by the specimen. Corresponding resultant force and force per kg of body weight on the suspensory apparatus, fetlock joint moment, and angle of fetlock dorsiflexion were calculated by use of specimen dimensions and applied load. These were compared along with specimen stiffness, and ram displacement. Load on the suspensory apparatus, load on the suspensory apparatus per kg of body weight, moment, applied load, and angle of fetlock dorsiflexion at yield failure were significantly greater for the TW-repaired than for the LS-repaired specimens. A 3 to 5 mm gap was observed before yield failure in most TW-repaired osteotomies. Transfixation wiring provided greater strength to yield failure than screws placed in lag fashion in single cycle load-to-failure mechanical testing of repaired transverse osteotomized specimens of the medial proximal forelimb sesamoid bone.
Cytoskeletal mechanics in pressure-overload cardiac hypertrophy
NASA Technical Reports Server (NTRS)
Tagawa, H.; Wang, N.; Narishige, T.; Ingber, D. E.; Zile, M. R.; Cooper, G. 4th
1997-01-01
We have shown that the cellular contractile dysfunction characteristic of pressure-overload cardiac hypertrophy results not from an abnormality intrinsic to the myofilament portion of the cardiocyte cytoskeleton but rather from an increased density of the microtubule component of the extramyofilament portion of the cardiocyte cytoskeleton. To determine how, in physical terms, this increased microtubule density mechanically overloads the contractile apparatus at the cellular level, we measured cytoskeletal stiffness and apparent viscosity in isolated cardiocytes via magnetic twisting cytometry, a technique by which magnetically induced force is applied directly to the cytoskeleton through integrin-coupled ferromagnetic beads coated with Arg-Gly-Asp (RGD) peptide. Measurements were made in two groups of cardiocytes from cats with right ventricular (RV) hypertrophy induced by pulmonary artery banding: (1) those from the pressure-overloaded RV and (2) those from the normally loaded same-animal control left ventricle (LV). Cytoskeletal stiffness increased almost twofold, from 8.53 +/- 0.77 dyne/cm2 in the normally loaded LV cardiocytes to 16.46 +/- 1.32 dyne/cm2 in the hypertrophied RV cardiocytes. Cytoskeletal apparent viscosity increased almost fourfold, from 20.97 +/- 1.92 poise in the normally loaded LV cardiocytes to 87.85 +/- 6.95 poise in the hypertrophied RV cardiocytes. In addition to these baseline data showing differing stiffness and, especially, apparent viscosity in the two groups of cardiocytes, microtubule depolymerization by colchicine was found to return both the stiffness and the apparent viscosity of the pressure overload-hypertrophied RV cells fully to normal. Conversely, microtubule hyperpolymerization by taxol increased the stiffness and apparent viscosity values of normally loaded LV cardiocytes to the abnormal values given above for pressure-hypertrophied RV cardiocytes. Thus, increased microtubule density constitutes primarily a viscous load on the cardiocyte contractile apparatus in pressure-overload cardiac hypertrophy.
Mahon, Marrita M; Cox, I Jane; Dina, Roberto; Soutter, W Patrick; McIndoe, G Angus; Williams, Andreanna D; deSouza, Nandita M
2004-03-01
To compare in vivo (1)H magnetic resonance (MR) spectra of preinvasive and invasive cervical lesions with ex vivo magic angle spinning (MAS) spectra of intact biopsies from the same subjects and to establish the effects of tumor load in the tissue sampled on the findings. A total of 51 subjects (nine with normal cervix, 10 with cervical intraepithelial neoplasia [CIN], and 32 with cervical cancer) underwent endovaginal MR at 1.5 T. Single-voxel (3.4 cm(3)) (1)H MR spectra were acquired and voxel tumor load was calculated (tumor volume within voxel as a percentage of voxel volume). Resonances from triglycerides -CH(2) and -CH(3) and choline-containing compounds (Cho) were correlated with voxel tumor load. Biopsies analyzed by (1)H MAS-MR spectroscopy (MRS) had metabolite levels correlated with tumor load in the sample at histology. In vivo studies detected Cho in normal, CIN, and cancer patients with no significant differences in levels (P = 0.93); levels were independent of voxel tumor load. Triglyceride -CH(2) and -CH(3) signals in-phase with Cho were present in 77% and 29%, respectively, of cancer subjects (but not in normal women or those with CIN), but did not correlate with voxel tumor load. Ex vivo cancer biopsies showed levels of triglycerides -CH(2) and -CH(3) and of Cho that were significantly greater than in normal or CIN biopsies (P < 0.05); levels were independent of the tumor load in the sample. The presence of -CH(2) in vivo predicted the presence of cancer with a sensitivity and specificity of 77.4% and 93.8% respectively, positive (PPV) and negative (NPV) predictive values were 96% and 68.2%; for -CH(2) ex vivo, sensitivity was 100%; specificity, 69%; PPV, 82%; and NPV, 100%. Elevated lipid levels are detected by MRS in vivo and ex vivo in cervical cancer and are independent of tumor load in the volume of tissue sampled. Copyright 2004 Wiley-Liss, Inc.
Trilateral Bridge Rating Criteria.
1982-04-01
and vehicle impact factor (i.e., V= VDES , G - G S , D- dm , I - imS). We take the Mud load as 0.8 times the design values (i.e., M - 0.8 ?S) and set...Artur D Ittek ln TABLE 4.1 SUMMARY OF VALUES USED IN NORMAL CROSSING Symbol Meaning Value VDES Design code vehicle weight 60 tons 9DES Design code gap...a caution crossing we first parametrically increase in vehicle weight or gap size, by V = (1+pv) VDES (5.1a) G = (1+pg) 9DES (5.1b) where 1 V is the
Nonstationary Deformation of an Elastic Layer with Mixed Boundary Conditions
NASA Astrophysics Data System (ADS)
Kubenko, V. D.
2016-11-01
The analytic solution to the plane problem for an elastic layer under a nonstationary surface load is found for mixed boundary conditions: normal stress and tangential displacement are specified on one side of the layer (fourth boundary-value problem of elasticity) and tangential stress and normal displacement are specified on the other side of the layer (second boundary-value problem of elasticity). The Laplace and Fourier integral transforms are applied. The inverse Laplace and Fourier transforms are found exactly using tabulated formulas and convolution theorems for various nonstationary loads. Explicit analytical expressions for stresses and displacements are derived. Loads applied to a constant surface area and to a surface area varying in a prescribed manner are considered. Computations demonstrate the dependence of the normal stress on time and spatial coordinates. Features of wave processes are analyzed
Modelling of Fiber/Matrix Debonding of Composites Under Cyclic Loading
NASA Technical Reports Server (NTRS)
Naghipour, Paria; Pineda, Evan J.; Bednarcyk, Brett A.; Arnold, Steven M.
2013-01-01
The micromechanics theory, generalized method of cells (GMC), was employed to simulate the debonding of fiber/matrix interfaces, within a repeating unit cell subjected to global, cyclic loading, utilizing a cyclic crack growth law. Cycle dependent, interfacial debonding was implemented as a new module to the available GMC formulation. The degradation of interfacial stresses, with applied load cycles, was achieved via progressive evolution of the interfacial compliance. A periodic repeating unit cell, representing the fiber/matrix architecture of a composite, was subjected to combined normal and shear loadings, and degradation of the global transverse stress in successive cycles was monitored. The obtained results were compared to values from a corresponding finite element model. Reasonable agreement was achieved for combined normal and shear loading conditions, with minimal variation for pure loading cases. The local effects of interfacial debonding, and fatigue damage will later be combined as sub-models to predict the experimentally obtained fatigue life of Ti-15-3/Sic composites at the laminate level.
Sun, L L; Chen, W; Fan, Y Y; Wang, M L; Wang, L N
2015-01-01
To characterize histopathological status, high-risk human papillomavirus (hr-HPV) infection status, and associated risk factors in patients with atypical squamous cells of undetermined significance (ASCUS). Cervical biopsies obtained from 130 ASCUS patients were subjected to histopathological examination and hr-HPV testing. Associations between advanced lesions and hr-HPV load or age were analyzed, and the confounding factors for high-grade cervical lesions were identified. Cervical biopsies from ASCUS patients had a wide range of pathological states, ranging from normal to invasive cervical carcinoma. High-risk HPV infection was significantly associated with advanced cervical lesions in ASCUS patients; hr-HPV infection and the number of gestations were risk factors for developing advanced cervical disease. A significant portion of ASCUS patients harbor advanced cervical lesions. The number of gestations and hr-HPV infection can increase the risk of developing advanced cervical lesions in ASCUS patients.
Time- & Load-Dependence of Triboelectric Effect.
Pan, Shuaihang; Yin, Nian; Zhang, Zhinan
2018-02-06
Time- and load-dependent friction behavior is considered as important for a long time, due to its time-evolution and force-driving characteristics. However, its electronic behavior, mainly considered in triboelectric effect, has almost never been given the full attention and analyses from the above point of view. In this paper, by experimenting with fcc-latticed aluminum and copper friction pairs, the mechanical and electronic behaviors of friction contacts are correlated by time and load analyses, and the behind physical understanding is provided. Most importantly, the difference of "response lag" in force and electricity is discussed, the extreme points of coefficient of friction with the increasing normal loads are observed and explained with the surface properties and dynamical behaviors (i.e. wear), and the micro and macro theories linking tribo-electricity to normal load and wear (i.e. the physical explanation between coupled electrical and mechanical phenomena) are successfully developed and tested.
NASA Astrophysics Data System (ADS)
Minka, N. S.; Ayo, J. O.
2012-03-01
The major factor in the induction of physiological stress during road transportation of livestock is the complex fluctuations of the thermal transport microenvironment, encountered when animals are transported across different ecological zones. Recommended guidelines on optimum "on-board" conditions in which goats should be transported are lacking, and there are no acceptable ranges and limits for the thermal loads to which goats may be subjected during long-distance road transportation in hot-dry conditions. Panting score (PS), rectal temperature (RT), heart rate (HR) and respiratory rate (RR) were employed as reliable stress indices to assess the effects of different thermal loads, measured as temperature humidity index (THI), encountered in the vehicle during 12 h of road transportation of 40 goats, and to suggest the administration of 100 mg/kg body weight of ascorbic acid (AA) as an ameliorating agent. The results obtained showed that the PS, RT, HR and RR rose above normal reference values with increase in the THI and journey duration. The rise in PS value, which is a visual indicator of the severity of thermal load, was the most pronounced. The results suggest that values of THI in the vehicle up to 94.6 constitute no risk, while at of 100 it presents a moderate risk and above 100 may result in severe stress. The relationships between the thermal load and the physiological variables were positive and significant ( P < 0.05). They reflect the degree of stress imposed by each THI value during the transportation, and may be used as recommended ranges and limit thermal load values in transported goats. The results demonstrated that administration of 100 mg/kg body weight of AA before road transportation mitigated the risk of adverse effects of high THI values and other stress factors due to road transportation in goats.
Cy5 total protein normalization in Western blot analysis.
Hagner-McWhirter, Åsa; Laurin, Ylva; Larsson, Anita; Bjerneld, Erik J; Rönn, Ola
2015-10-01
Western blotting is a widely used method for analyzing specific target proteins in complex protein samples. Housekeeping proteins are often used for normalization to correct for uneven sample loads, but these require careful validation since expression levels may vary with cell type and treatment. We present a new, more reliable method for normalization using Cy5-prelabeled total protein as a loading control. We used a prelabeling protocol based on Cy5 N-hydroxysuccinimide ester labeling that produces a linear signal response. We obtained a low coefficient of variation (CV) of 7% between the ratio of extracellular signal-regulated kinase (ERK1/2) target to Cy5 total protein control signals over the whole loading range from 2.5 to 20.0μg of Chinese hamster ovary cell lysate protein. Corresponding experiments using actin or tubulin as controls for normalization resulted in CVs of 13 and 18%, respectively. Glyceraldehyde-3-phosphate dehydrogenase did not produce a proportional signal and was not suitable for normalization in these cells. A comparison of ERK1/2 signals from labeled and unlabeled samples showed that Cy5 prelabeling did not affect antibody binding. By using total protein normalization we analyzed PP2A and Smad2/3 levels with high confidence. Copyright © 2015 Elsevier Inc. All rights reserved.
Li, Junyan; Redmond, Anthony C; Jin, Zhongmin; Fisher, John; Stone, Martin H; Stewart, Todd D
2014-08-01
Preclinical durability testing of hip replacement implants is standardised by ISO-14242-1 (2002) which is based on historical inverse dynamics analysis using data obtained from a small sample of normal healthy individuals. It has not been established whether loading cycles derived from normal healthy individuals are representative of loading cycles occurring in patients following total hip replacement. Hip joint kinematics and hip contact forces derived from multibody modelling of forces during normal walking were obtained for 15 asymptomatic total hip replacement patients and compared to 38 normal healthy individuals and to the ISO standard for pre-clinical testing. Hip kinematics in the total hip replacement patients were comparable to the ISO data and the hip contact force in the normal healthy group was also comparable to the ISO cycles. Hip contact forces derived from the asymptomatic total hip replacement patients were comparable for the first part of the stance period but exhibited 30% lower peak loads at toe-off. Although the ISO standard provides a representative kinematic cycle, the findings call into question whether the hip joint contact forces in the ISO standard are representative of those occurring in the joint following total hip replacement. Copyright © 2014. Published by Elsevier Ltd.
A Baseline Load Schedule for the Manual Calibration of a Force Balance
NASA Technical Reports Server (NTRS)
Ulbrich, N.; Gisler, R.
2013-01-01
A baseline load schedule for the manual calibration of a force balance is defined that takes current capabilities at the NASA Ames Balance Calibration Laboratory into account. The chosen load schedule consists of 18 load series with a total of 194 data points. It was designed to satisfy six requirements: (i) positive and negative loadings should be applied for each load component; (ii) at least three loadings should be applied between 0 % and 100 % load capacity; (iii) normal and side force loadings should be applied at the forward gage location, aft gage location, and the balance moment center; (iv) the balance should be used in "up" and "down" orientation to get positive and negative axial force loadings; (v) the constant normal and side force approaches should be used to get the rolling moment loadings; (vi) rolling moment loadings should be obtained for 0, 90, 180, and 270 degrees balance orientation. In addition, three different approaches are discussed in the paper that may be used to independently estimate the natural zeros, i.e., the gage outputs of the absolute load datum of the balance. These three approaches provide gage output differences that can be used to estimate the weight of both the metric and non-metric part of the balance. Data from the calibration of a six-component force balance will be used in the final manuscript of the paper to illustrate characteristics of the proposed baseline load schedule.
14 CFR 398.9 - Load factor standards.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 4 2010-01-01 2010-01-01 false Load factor standards. 398.9 Section 398.9... STATEMENTS GUIDELINES FOR INDIVIDUAL DETERMINATIONS OF BASIC ESSENTIAL AIR SERVICE § 398.9 Load factor standards. The load factor standards used in this part may be raised for individual eligible places under...
14 CFR 25.337 - Limit maneuvering load factors.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Limit maneuvering load factors. 25.337... Conditions § 25.337 Limit maneuvering load factors. (a) Except where limited by maximum (static) lift... maneuvering load factors prescribed in this section. Pitching velocities appropriate to the corresponding pull...
[The links between learning load and well-being of high school seniors].
Petrauskiene, Ausra; Matuleviciūte, Deimante
2007-01-01
To evaluate the links between learning overload and psychoemotional well-being of 12th grade students. In April 2006, an anonymous survey of 184 high school seniors was conducted in six secondary schools and one gymnasium of Kaunas. The total learning load of students was too high and made up 54.79+/-0.98 hours on average. The learning load of 61.4% of children was too high; girls mentioned this problem two times more often than boys did. Students suffered from psychoemotional problems: about half of them felt stress at school; every fifth fell asleep with difficulties. Students whose total learning load was too high (more than 48 hours per week) felt stress, tiredness, stomach or abdominal, head or back pains, vertigo or weakness significantly more often in comparison with those who had normal learning load. The total learning load of the majority of investigated high school seniors was too high. The psychoemotional well-being of 12th graders was unsatisfactory; girls complained about worse well-being than boys more frequently, they used medicine more frequently in comparison to the students whose learning load was normal.
Active Flap Control of the SMART Rotor for Vibration Reduction
NASA Technical Reports Server (NTRS)
Hall, Steven R.; Anand, R. Vaidyanathan; Straub, Friedrich K.; Lau, Benton H.
2009-01-01
Active control methodologies were applied to a full-scale active flap rotor obtained during a joint Boeing/ DARPA/NASA/Army test in the Air Force National Full-Scale Aerodynamic Complex 40- by 80-foot anechoic wind tunnel. The active flap rotor is a full-scale MD 900 helicopter main rotor with each of its five blades modified to include an on-blade piezoelectric actuator-driven flap with a span of 18% of radius, 25% of chord, and located at 83% radius. Vibration control demonstrated the potential of active flaps for effective control of vibratory loads, especially normal force loads. Active control of normal force vibratory loads using active flaps and a continuous-time higher harmonic control algorithm was very effective, reducing harmonic (1-5P) normal force vibratory loads by 95% in both cruise and approach conditions. Control of vibratory roll and pitch moments was also demonstrated, although moment control was less effective than normal force control. Finally, active control was used to precisely control blade flap position for correlation with pretest predictions of rotor aeroacoustics. Flap displacements were commanded to follow specific harmonic profiles of 2 deg or more in amplitude, and the flap deflection errors obtained were less than 0.2 deg r.m.s.
Experimental study on ignition mechanisms of wet granulation sulfur caused by friction.
Dai, Haoyuan; Fan, Jianchun; Wu, Shengnan; Yu, Yanqiu; Liu, Di; Hu, Zhibin
2018-02-15
It is common to see fire accidents caused by friction during the storage and transportation of wet granulation sulfur. To study the sulfur ignition mechanism under friction conditions, a new rotating test apparatus is developed to reproduce friction scenes at lab scale. A series of experiments are performed under different normal loads. The SEM-EDS and the XRD were utilized to examine the morphologies and compositions of the tested specimens and the friction products. Experimental results show that these two methods are mostly in agreement with each other. The iron-sulfide compounds are produced and the proportion of iron-sulfide compounds is reduced with normal loads increasing, compared to the total number of the friction products. The facts implied by the integration analysis of friction products with the temperature changes of the near friction surface unveil an underlying mechanism that may explain sulfur ignition by friction in real scenarios. The sulfur ignition may be mainly caused by the spontaneous combustion of iron sulfide compounds produced by friction under low normal load with 200N. With the increase of normal loads, the resulting iron-sulfide compounds are decreasing and the high temperature from friction heat begins to play a major role in causing fire. Copyright © 2017 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schultz, Bradley M.; Li, Nan; Economy, David R.
Mathematical models suggest that the strain along the film formed by parallel passes of a nanoindentation probe in contact with the film can be either homogenous or heterogeneous, depending on contact pressure and spacing between passes. Here, in this study, a 1 µm copper thin film was worn with a cono-spherical diamond probe with normal loads ranging from 25 to 800 µN and wear box edge lengths of 40, 60, and 80 µm. The nanoindenter counterface was rastered across the surface to mimic dry sliding wear. To determine potential strain field changes, 10-step quasi-static indents (200–2000 µN) were performed usingmore » nanoindentation inside the wear boxes created at various loads to determine if a strain field alteration could be observed in changes in hardness of the copper thin film. It was shown that there was a softening effect in the hardness for normal loads < 400 µN used during nanowear compared to the as-deposited copper. Normal loads ≥ 400 µN had a similar or higher hardness than the as-deposited copper. This is believed to have occurred due to a relaxation in the residual stresses created during deposition in the copper thin films at lower loads, which caused a decrease in hardness. Conversely, at the higher loads, increased deformation leads to an increase in hardness. Lastly, all of the wear boxes displayed a higher estimated strain hardening exponent than the as-deposited material.« less
Koh, Y-G.; Son, J.; Kwon, S-K.; Kim, H-J.; Kang, K-T.
2017-01-01
Objectives Preservation of both anterior and posterior cruciate ligaments in total knee arthroplasty (TKA) can lead to near-normal post-operative joint mechanics and improved knee function. We hypothesised that a patient-specific bicruciate-retaining prosthesis preserves near-normal kinematics better than standard off-the-shelf posterior cruciate-retaining and bicruciate-retaining prostheses in TKA. Methods We developed the validated models to evaluate the post-operative kinematics in patient-specific bicruciate-retaining, standard off-the-shelf bicruciate-retaining and posterior cruciate-retaining TKA under gait and deep knee bend loading conditions using numerical simulation. Results Tibial posterior translation and internal rotation in patient-specific bicruciate-retaining prostheses preserved near-normal kinematics better than other standard off-the-shelf prostheses under gait loading conditions. Differences from normal kinematics were minimised for femoral rollback and internal-external rotation in patient-specific bicruciate-retaining, followed by standard off-the-shelf bicruciate-retaining and posterior cruciate-retaining TKA under deep knee bend loading conditions. Moreover, the standard off-the-shelf posterior cruciate-retaining TKA in this study showed the most abnormal performance in kinematics under gait and deep knee bend loading conditions, whereas patient-specific bicruciate-retaining TKA led to near-normal kinematics. Conclusion This study showed that restoration of the normal geometry of the knee joint in patient-specific bicruciate-retaining TKA and preservation of the anterior cruciate ligament can lead to improvement in kinematics compared with the standard off-the-shelf posterior cruciate-retaining and bicruciate-retaining TKA. Cite this article: Y-G. Koh, J. Son, S-K. Kwon, H-J. Kim, O-R. Kwon, K-T. Kang. Preservation of kinematics with posterior cruciate-, bicruciate- and patient-specific bicruciate-retaining prostheses in total knee arthroplasty by using computational simulation with normal knee model. Bone Joint Res 2017;6:557–565. DOI: 10.1302/2046-3758.69.BJR-2016-0250.R1. PMID:28947604
Activity vs. rest in the treatment of bone, soft tissue and joint injuries.
Buckwalter, J A
1995-01-01
One of the most important advances in the treatment of musculoskeletal injuries has come from understanding that controlled early resumption of activity can promote restoration of function, and that treatment of injuries with prolonged rest may delay recovery and adversely affect normal tissues. In the last decade of the nineteenth century two widely respected orthopaedists with extensive clinical experience strongly advocated opposing treatments of musculoskeletal injuries. Hugh Owen Thomas in Liverpool believed that enforced, uninterrupted prolonged rest produced the best results. He noted that movement of injured tissues increased inflammation, and that, "It would indeed be as reasonable to attempt to cure a fever patient by kicking him out of bed, as to benefit joint disease by a wriggling at the articulation." Just Lucas-Championnier in Paris took the opposite position. He argued that early controlled active motion accelerated restoration of function, although he noted that mobility had to be given in limited doses. In general, Thomas' views met with greater acceptance in the early part of this century, but experimental studies of the last several decades generally support Lucas-Championneir. They confirm and help explain the deleterious effects of prolonged rest and the beneficial effects of activity on the musculoskeletal tissues. They have shown that maintenance of normal bone, tendon and ligament, articular cartilage and muscle structure and composition require repetitive use, and that changes in the patterns of tissue loading can strengthen or weaken normal tissues. Although all the musculoskeletal tissues can respond to repetitive loading, they vary in the magnitude and type of response to specific patterns of activity. Furthermore, their responsiveness may decline with increasing age. Skeletal muscle and bone demonstrate the most apparent response to changes in activity in individuals of any age. Cartilage and dense fibrous tissues also can respond to loading, but the responses are more difficult to measure. The effects of loading on injured tissues have been less extensively studied, but the available evidence indicates that repair tissues respond to loading and, like immature normal tissues, may be more sensitive to cyclic loading and motion than mature normal tissues. However, early motion and loading of injured tissues is not without risks. Premature or excessive loading and motion of repair tissue can inhibit or stop repair. Unfortunately, the optimal methods of facilitating healing by early application of loading and motion have not been defined.(ABSTRACT TRUNCATED AT 400 WORDS)
Fouda, Mohamed B; Thankam, Finosh G; Dilisio, Matthew F; Agrawal, Devendra K
2017-01-01
Rotator cuff (RC) tendons could beinflicted in many ways with an eventual outcome of pain, weakness and disability, which represent a large burden on health care cost. However, optimal healing, either conservatively or with surgical intervention, remains an issue that needs further investigation. Disorders of the RC tendons may result from external factors like trauma, or internal factors through physiologic and metabolic derangement. Most RC tendon disorders may be asymptomatic and may result from an over-activity of the inflicted shoulder and its tendons. Such tendon disorders are poorly diagnosed since patients do not seek medical attention until pain or weakness ensue. Immunological and biochemical events in RC disorders due to mechanical intolerance have not been investigated. Generally, the mechanical load drives normal physiological properties of the tendon. But, mechanical overload/burden exerts stress on tenocytes, and disrupts the tendon microenvironment by triggering a multitude of signaling pathways leading to extracellular matrix remodeling, disorganization, alteration in collagen composition and apoptosis. These events result in weak tendon which is highly susceptible to rupture or tear. In this article, we critically reviewed the intrinsic signaling pathways that are excessively triggered by continuous mechanical load and the counteracting physiological responses and associated derangements. The elucidation of the molecular events underlying mechanical stress-induced symptomatic/asymptomatic tendinopathy could provide information on potential target sites for translational application in the management of rotator cuff disorders. PMID:29118899
Gulati, Shelly; Stubblefield, Ashley A; Hanlon, Jeremy S; Spier, Chelsea L; Stringfellow, William T
2014-03-01
Measuring the discharge of diffuse pollution from agricultural watersheds presents unique challenges. Flows in agricultural watersheds, particularly in Mediterranean climates, can be predominately irrigation runoff and exhibit large diurnal fluctuation in both volume and concentration. Flow and pollutant concentrations in these smaller watersheds dominated by human activity do not conform to a normal distribution and it is not clear if parametric methods are appropriate or accurate for load calculations. The objective of this study was to compare the accuracy of five load estimation methods to calculate pollutant loads from agricultural watersheds. Calculation of loads using results from discrete (grab) samples was compared with the true-load computed using in situ continuous monitoring measurements. A new method is introduced that uses a non-parametric measure of central tendency (the median) to calculate loads (median-load). The median-load method was compared to more commonly used parametric estimation methods which rely on using the mean as a measure of central tendency (mean-load and daily-load), a method that utilizes the total flow volume (volume-load), and a method that uses measure of flow at the time of sampling (instantaneous-load). Using measurements from ten watersheds in the San Joaquin Valley of California, the average percent error compared to the true-load for total dissolved solids (TDS) was 7.3% for the median-load, 6.9% for the mean-load, 6.9% for the volume-load, 16.9% for the instantaneous-load, and 18.7% for the daily-load methods of calculation. The results of this study show that parametric methods are surprisingly accurate, even for data that have starkly non-normal distributions and are highly skewed. Copyright © 2013 Elsevier Ltd. All rights reserved.
Purevsuren, Tserenchimed; Dorj, Ariunzaya; Kim, Kyungsoo; Kim, Yoon Hyuk
2016-04-01
The computational modeling approach has commonly been used to predict knee joint contact forces, muscle forces, and ligament loads during activities of daily living. Knowledge of these forces has several potential applications, for example, within design of equipment to protect the knee joint from injury and to plan adequate rehabilitation protocols, although clinical applications of computational models are still evolving and one of the limiting factors is model validation. The objective of this study was to extend previous modeling technique and to improve the validity of the model prediction using publicly available data set of the fifth "Grand Challenge Competition to Predict In Vivo Knee Loads." A two-stage modeling approach, which combines conventional inverse dynamic analysis (the first stage) with a multi-body subject-specific lower limb model (the second stage), was used to calculate medial and lateral compartment contact forces. The validation was performed by direct comparison of model predictions and experimental measurement of medial and lateral compartment contact forces during normal and turning gait. The model predictions of both medial and lateral contact forces showed strong correlations with experimental measurements in normal gait (r = 0.75 and 0.71) and in turning gait trials (r = 0.86 and 0.72), even though the current technique over-estimated medial compartment contact forces in swing phase. The correlation coefficient, Sprague and Geers metrics, and root mean squared error indicated that the lateral contact forces were predicted better than medial contact forces in comparison with the experimental measurements during both normal and turning gait trials. © IMechE 2016.
Berahmani, Sanaz; Hendriks, Maartje; Wolfson, David; Wright, Abraham; Janssen, Dennis; Verdonschot, Nico
2017-11-01
To achieve long-lasting fixation of cementless implants, an adequate primary stability is required. We aimed to compare primary stability of a new cementless femoral knee component (Attune®) against a conventional implant (LCS®) under different loading conditions. Six pairs of femora were prepared following the normal surgical procedure. Calibrated CT-scans and 3D-optical scans of the bones were obtained to measure bone mineral density (BMD) and cut accuracy, respectively. Micromotions were measured in nine regions of interest at the bone-implant interface using digital image correlation. The reconstructions were subjected to the implant-specific's peak tibiofemoral load of gait and a deep knee bend loading profiles. Afterwards, the implants were pushed-off at a flexion angle of 150°. Micromotions of Attune were significantly lower than LCS under both loading conditions (P ≤ 0.001). Cut accuracy did not affect micromotions, and BMD was only a significant factor affecting the micromotions under simplified gait loading. No significant difference was found in high-flex push-off force, but Attune required a significantly higher load to generate excessive micromotions during push-off. Parallel anterior and posterior bone cuts in the LCS versus the tapered bone cuts of the Attune may explain the difference between the two designs. Additionally, the rims at the borders of the LCS likely reduced the area of contact with the bone for the LCS, which may have affected the initial fixation. Copyright © 2017 Elsevier Ltd. All rights reserved.
Skeletal Adaptation to Daily Activity: A Biochemical Perspective
NASA Technical Reports Server (NTRS)
Whalen, Robert T.; Dalton, Bonnie (Technical Monitor)
2002-01-01
Musculoskeletal forces generated by normal daily activity on Earth maintain the functional and structural properties of muscle and bone throughout most of one's adult life. A reduction in the level of cumulative daily loading caused by space flight, bed rest or spinal cord injury induces rapid muscle atrophy, functional changes in muscle, and bone resorption in regions subjected to the reduced loading. Bone cells in culture and bone tissue reportedly respond to a wide variety of non-mechanical and mechanical stimuli ranging, from electromagnetic fields, and hormones to small amplitude, high frequency vibrations, fluid flow, strain rate, and stress/strain magnitude. However, neither the transduction mechanism that transforms the mechanical input into a muscle or bone metabolic response nor the characteristics, of the loading history that directly or indirectly stimulates the cell is known. Identifying the factors contributing to the input stimulus will have a major impact on the design of effective countermeasures for long duration space flight. This talk will present a brief overview of current theories of bone remodeling and functional adaptation to mechanical loading. Work from our lab will be presented from the perspective of daily cumulative loading on Earth and its relationship to bone density and structure. Our objective is to use the tibia and calcaneus as model bone sites of cortical and cancellous bone adaptation, loaded daily by musculoskeletal forces in equilibrium with the ground reaction force. All materials that will be discussed are in the open scientific literature.
NASA Technical Reports Server (NTRS)
Ratcliffe, James G.; Johnston, William M., Jr.
2014-01-01
Mixed mode I-mode II interlaminar tests were conducted on IM7/8552 tape laminates using the mixed-mode bending test. Three mixed mode ratios, G(sub II)/G(sub T) = 0.2, 0.5, and 0.8, were considered. Tests were performed at all three mixed-mode ratios under quasi-static and cyclic loading conditions, where the former static tests were used to determine initial loading levels for the latter fatigue tests. Fatigue tests at each mixed-mode ratio were performed at four loading levels, Gmax, equal to 0.5G(sub c), 0.4G(sub c), 0.3G(sub c), and 0.2G(sub c), where G(sub c) is the interlaminar fracture toughness of the corresponding mixed-mode ratio at which a test was performed. All fatigue tests were performed using constant-amplitude load control and delamination growth was automatically documented using compliance solutions obtained from the corresponding quasi-static tests. Static fracture toughness data yielded a mixed-mode delamination criterion that exhibited monotonic increase in Gc with mixed-mode ratio, G(sub II)/G(sub T). Fatigue delamination onset parameters varied monotonically with G(sub II)/G(sub T), which was expected based on the fracture toughness data. Analysis of non-normalized data yielded a monotonic change in Paris law exponent with mode ratio. This was not the case when normalized data were analyzed. Fatigue data normalized by the static R-curve were most affected in specimens tested at G(sub II)/G(sub T)=0.2 (this process has little influence on the other data). In this case, the normalized data yielded a higher delamination growth rate compared to the raw data for a given loading level. Overall, fiber bridging appeared to be the dominant mechanism, affecting delamination growth rates in specimens tested at different load levels and differing mixed-mode ratios.
Computer-assisted recording of tensile tests for the evaluation of serrated flow
DOE Office of Scientific and Technical Information (OSTI.GOV)
Weinhandl, H.; Mitter, F.; Bernt, W.
1994-12-01
In a previous paper the authors pointed out the difficulties which arise in the evaluation of serrated flow curves when the applied tensile strain rates are just above normal''. The recording system of tensile testing machines which were built, say, twenty years ago, are not capable of recording the full size of the load drops due to the inertia of the recording pen. This handicap was then overcome by establishing correction factors which were determined from recording a small number of load drops with an oscilloscope. Modern testing machines are equipped with digital recording. The disadvantage of the common systemmore » is, however, their limited capacity, so that not enough space for data points is available. Consequently, the time intervals between data points are of the order of tenths of seconds. It will become obvious from the present results that such a time interval is too large for recording a correct serration size. This report is concerned with the recording of complete load-extension relations during tensile tests using a computer which is capable of storing the data at sufficiently small time intervals.« less
Manconi, Maria; Manca, Maria Letizia; Caddeo, Carla; Cencetti, Claudia; di Meo, Chiara; Zoratto, Nicole; Nacher, Amparo; Fadda, Anna Maria; Matricardi, Pietro
2018-06-01
In the present work, the preparation, characterization and therapeutic potential of baicalin-loaded nanohydrogels are reported. The nanohydrogels were prepared by sonicating (S nanohydrogel) or autoclaving (A nanohydrogel) a dispersion of cholesterol-derivatized gellan in phosphate buffer. The nanohydrogel obtained by autoclave treatment showed the most promising results: smaller particles (∼362 nm vs. ∼530 nm), higher homogeneity (polydispersity index = ∼0.24 vs. ∼0.47), and lower viscosity than those obtained by sonication. In vitro studies demonstrated the ability of the nanohydrogels to favour the deposition of baicalin in the epidermis. A high biocompatibility was found for baicalin-loaded nanohydrogels, along with a great ability to counteract the toxic effect induced by hydrogen peroxide in cells, as the nanohydrogels re-established the normal conditions (∼100% viability). Further, the potential of baicalin-loaded nanohydrogels in skin wound healing was demonstrated in vivo in mice by complete skin restoration and inhibition of specific inflammatory markers (i.e., myeloperoxidase, tumor necrosis factor-α, and oedema). Copyright © 2018 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Guo, Hang; Liu, Xuan; Zhao, Jian Fu; Ye, Fang; Ma, Chong Fang
2017-06-01
In this work, proton exchange membrane fuel cells (PEMFCs) with transparent windows are designed to study the gas-liquid two-phase flow behaviors inside flow channels and the performance of a PEMFC with vertical channels and a PEMFC with horizontal channels in a normal gravity environment and a 3.6 s short-term microgravity environment. Experiments are conducted under high external circuit load and low external circuit load at low temperature where is 35 °C. The results of the present experimental work demonstrate that the performance and the gas-liquid two-phase flow behaviors of the PEMFC with vertical channels exhibits obvious changes when the PEMFCs enter the 3.6 s short-term microgravity environment from the normal gravity environment. Meanwhile, the performance of the PEMFC with vertical channels increases after the PEMFC enters the 3.6 s short-term microgravity environment under high external circuit load, while under low external circuit load, the PEMFC with horizontal channels exhibits better performance in both the normal gravity environment and the 3.6 s short-term microgravity environment.
14 CFR 25.683 - Operation tests.
Code of Federal Regulations, 2010 CFR
2010-01-01
... STANDARDS: TRANSPORT CATEGORY AIRPLANES Design and Construction Control Systems § 25.683 Operation tests. It must be shown by operation tests that when portions of the control system subject to pilot effort loads... control system are loaded to the maximum load expected in normal operation, the system is free from— (a...
14 CFR 25.683 - Operation tests.
Code of Federal Regulations, 2011 CFR
2011-01-01
... STANDARDS: TRANSPORT CATEGORY AIRPLANES Design and Construction Control Systems § 25.683 Operation tests. It must be shown by operation tests that when portions of the control system subject to pilot effort loads... control system are loaded to the maximum load expected in normal operation, the system is free from— (a...
14 CFR 25.683 - Operation tests.
Code of Federal Regulations, 2014 CFR
2014-01-01
... STANDARDS: TRANSPORT CATEGORY AIRPLANES Design and Construction Control Systems § 25.683 Operation tests. It must be shown by operation tests that when portions of the control system subject to pilot effort loads... control system are loaded to the maximum load expected in normal operation, the system is free from— (a...
14 CFR 25.683 - Operation tests.
Code of Federal Regulations, 2012 CFR
2012-01-01
... STANDARDS: TRANSPORT CATEGORY AIRPLANES Design and Construction Control Systems § 25.683 Operation tests. It must be shown by operation tests that when portions of the control system subject to pilot effort loads... control system are loaded to the maximum load expected in normal operation, the system is free from— (a...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kelekis, Alexios, E-mail: akelekis@med.uoa.gr; Filippiadis, Dimitrios K., E-mail: dfilippiadis@yahoo.gr; Vergadis, Chrysovalantis, E-mail: valvergadis@yahoo.gr
PurposeThrough a prospective comparison of patients with vertebral fractures and normal population, we illustrate effect of percutaneous vertebroplasty (PV) upon projection of load distribution changes.MethodsVertebroplasty group (36 symptomatic patients with osteoporotic vertebral fractures) was evaluated on an electronic baropodometer registering projection of weight bearing areas on feet. Load distribution between right and left foot (including rear-front of the same foot) during standing and walking was recorded and compared before (group V1) and the day after (group V2) PV. Control group (30 healthy asymptomatic volunteers-no surgery record) were evaluated on the same baropodometer.ResultsMean value of load distribution difference between rear-front ofmore » the same foot was 9.45 ± 6.79 % (54.72–45.28 %) upon standing and 14.76 ± 7.09 % (57.38–42.62 %) upon walking in the control group. Respective load distribution values before PV were 16.52 ± 11.23 and 30.91 ± 19.26 % and after PV were 10.08 ± 6.26 and 14.25 ± 7.68 % upon standing and walking respectively. Mean value of load distribution variation between the two feet was 6.36 and 14.6 % before and 4.62 and 10.4 % after PV upon standing and walking respectively. Comparison of load distribution variation (group V1–V2, group V1-control group) is statistically significant. Comparison of load distribution variation (group V2-control group) is not statistically significant. Comparison of load distribution variation among the two feet is statistically significant during walking but not statistically significant during standing.ConclusionsThere is a statistically significant difference when comparing load distribution variation prior vertebroplasty and that of normal population. After vertebroplasty, this difference normalizes in a statistically significant way. PV is efficient on equilibrium-load distribution improvement as well.« less
Borehole Shear Device Phase II Development.
1982-02-01
FIGURE 8 ITEM QUANTITY DESCRIPTION B1 1 Torque/Normal Load Transducer - First Extension Coupling. B2 1 Torque/Normal Load Transducer - Gauge Tube. B3 I...235, type RFN 7012. Supplier - Ringfeder Limited, Forum Drive, Midland Indus- trial Estate, Rugby , Warwickshire CV21 iNT, UK. FB 1 Expanding Friction...Midland Industrial Estate, Rugby , Warwickshire CV21 INT, UK. GF 2 Deep Groove Ball Bearing (upper support bearing), 80 x 100 x 10. Supplier - SKF ref
Strongly Modulated Friction of a Film-Terminated Ridge-Channel Structure.
He, Zhenping; Hui, Chung-Yuen; Levrard, Benjamin; Bai, Ying; Jagota, Anand
2016-05-26
Natural contacting surfaces have remarkable surface mechanical properties, which has led to the development of bioinspired surface structures using rubbery materials with strongly enhanced adhesion and static friction. However, sliding friction of structured rubbery surfaces is almost always significantly lower than that of a flat control, often due to significant loss of contact. Here we show that a film-terminated ridge-channel structure can strongly enhance sliding friction. We show that with properly chosen materials and geometrical parameters the near surface structure undergoes mechanical instabilities along with complex folding and sliding of internal interfaces, which is responsible for the enhancement of sliding friction. Because this structure shows no enhancement of adhesion under normal indentation by a sphere, it breaks the connection between energy loss during normal and shear loading. This makes it potentially interesting in many applications, for instance in tires, where one wishes to minimize rolling resistance (normal loading) while maximizing sliding friction (shear loading).
Caravaggi, Paolo; Leardini, Alberto; Giacomozzi, Claudia
2016-10-03
Plantar load can be considered as a measure of the foot ability to transmit forces at the foot/ground, or foot/footwear interface during ambulatory activities via the lower limb kinematic chain. While morphological and functional measures have been shown to be correlated with plantar load, no exhaustive data are currently available on the possible relationships between range of motion of foot joints and plantar load regional parameters. Joints' kinematics from a validated multi-segmental foot model were recorded together with plantar pressure parameters in 21 normal-arched healthy subjects during three barefoot walking trials. Plantar pressure maps were divided into six anatomically-based regions of interest associated to corresponding foot segments. A stepwise multiple regression analysis was performed to determine the relationships between pressure-based parameters, joints range of motion and normalized walking speed (speed/subject height). Sagittal- and frontal-plane joint motion were those most correlated to plantar load. Foot joints' range of motion and normalized walking speed explained between 6% and 43% of the model variance (adjusted R 2 ) for pressure-based parameters. In general, those joints' presenting lower mobility during stance were associated to lower vertical force at forefoot and to larger mean and peak pressure at hindfoot and forefoot. Normalized walking speed was always positively correlated to mean and peak pressure at hindfoot and forefoot. While a large variance in plantar pressure data is still not accounted for by the present models, this study provides statistical corroboration of the close relationship between joint mobility and plantar pressure during stance in the normal healthy foot. Copyright © 2016 Elsevier Ltd. All rights reserved.
Hashida, Yumiko; Nakajima, Kimiko; Nakajima, Hideki; Shiga, Takeo; Tanaka, Moe; Murakami, Masanao; Matsuzaki, Shigenobu; Naganuma, Seiji; Kuroda, Naoki; Seki, Yasutaka; Katano, Harutaka; Sano, Shigetoshi; Daibata, Masanori
2016-09-01
Although Merkel cell polyomavirus (MCPyV) has the potential to cause Merkel cell carcinoma (MCC), it is also found in the normal skin of healthy individuals. However, the mechanism for transformation of MCPyV to an oncogenic form is unknown. To investigate the levels of MCPyV infection in the normal skin patients with MCC compared with those in a control cohort. We studied a total of six Japanese patients with cutaneous MCC. Sun-exposed and sun-unexposed skin swabs were obtained and analyzed for MCPyV loads using quantitative real-time polymerase chain reaction. At first, we found a patient with MCC carrying an extremely high load of MCPyV DNA in normal skin. This unique case prompted us to further explore the levels of MCPyV as skin microbiota in patients with MCC. We showed that MCPyV DNA levels were significantly higher in swabs obtained from normal skin samples of six patients with MCC compared with those from 30 age-matched healthy individuals and 19 patients with other cutaneous cancers. Whereas MCPyV strains obtained from the normal skin of patients with MCC had gene sequences without structural alterations, sequences of the tumor-derived strains showed truncating mutations or deletions. Although the number of patients with MCC studied was small, our findings suggest that MCC may occur with a background of high MCPyV load in the skin, and are expected to stimulate further studies on whether such skin virome levels could be one of predictive markers for the development of MCC. Copyright © 2016 Elsevier B.V. All rights reserved.
Informing Stem Cell-Based Tendon Tissue Engineering Approaches with Embryonic Tendon Development.
Okech, William; Kuo, Catherine K
Adult tendons fail to regenerate normal tissue after injury, and instead form dysfunctional scar tissue with abnormal mechanical properties. Surgical repair with grafts is the current standard to treat injuries, but faces significant limitations including pain and high rates of re-injury. To address this, we aim to regenerate new, normal tendons to replace dysfunctional tendons. A common approach to tendon tissue engineering is to design scaffolds and bioreactors based on adult tendon properties that can direct adult stem cell tenogenesis. Despite significant progress, advances have been limited due, in part, to a need for markers and potent induction cues. Our goal is to develop novel tendon tissue engineering approaches informed by embryonic tendon development. We are characterizing structure-property relationships of embryonic tendon to identify design parameters for three-dimensional scaffolds and bioreactor mechanical loading systems to direct adult stem cell tenogenesis. We will review studies in which we quantified changes in the mechanical and biochemical properties of tendon during embryonic development and elucidated specific mechanisms of functional property elaboration. We then examined the effects of these mechanical and biochemical factors on embryonic tendon cell behavior. Using custom-designed bioreactors, we also examined the effects of dynamic mechanical loading and growth factor treatment on embryonic tendon cells. Our findings have established cues to induce tenogenesis as well as metrics to evaluate differentiation. We finish by discussing how we have evaluated the tenogenic differentiation potential of adult stem cells by comparing their responses to that of embryonic tendon cells in these culture systems.
NASA Technical Reports Server (NTRS)
Chio, S. R.; Gyekenyesi, J. P.
1999-01-01
A two-dimensional, numerical analysis of slow crack growth (SCG) was performed for brittle materials with finite thickness subjected to constant stress-rate ("dynamic fatigue") loading in flexure. The numerical solution showed that the conventional, simple, one-dimensional analytical solution can be used with a maximum error of about 5% in determining the SCG parameters of a brittle material with the conditions of a normalized thickness (a ratio of specimen thickness to initial crack size) T > 3.3 and of a SCG parameter n > 10. The change in crack shape from semicircular to elliptical configurations was significant particularly at both low stress rate and low T, attributed to predominant difference in stress intensity factor along the crack front. The numerical solution of SCG parameters was supported within the experimental range by the data obtained from constant stress-rate flexural testing for soda-lime glass microslides at ambient temperature.
Friction and Wear Behavior of Carbon Fabric-Reinforced Epoxy Composites
NASA Astrophysics Data System (ADS)
Şahin, Y.; De Baets, Patrick
2017-12-01
Besides intrinsic material properties, weight/energy savings and wear performance play an important role in the selection of materials for any engineering application. The tribological behavior of carbon fabric-reinforced epoxy composites produced by molding technique was investigated using a reciprocating pin-on-plate configuration. It was shown that the wear rate considerably decreased (by a factor of approx. 8) with the introduction of the reinforcing carbon fabric into the epoxy matrix. It was observed that the wear rate of the tested composites increased with an increase in normal load. Moreover, the coefficient of friction for epoxy/steel and composites/steel tribo-pairs was also determined and decreased with increasing load. By means of scanning electron microscopy of the wear tracks, different wear mechanisms such as matrix wear, matrix fatigue and cracking, matrix debris formation for neat epoxy together with fabric/fiber thinning, fabric breakage and fabric/matrix debonding for the reinforced epoxy could be distinguished.
Photovoltaic array: Power conditioner interface characteristics
NASA Technical Reports Server (NTRS)
Gonzalez, C. C.; Hill, G. M.; Ross, R. G., Jr.
1982-01-01
The electrical output (power, current, and voltage) of flat plate solar arrays changes constantly, due primarily to changes in cell temperature and irradiance level. As a result, array loads such as dc-to-ac power conditioners must be capable of accommodating widely varying input levels while maintaining operation at or near the maximum power point of the array. The array operating characteristics and extreme output limits necessary for the systematic design of array load interfaces under a wide variety of climatic conditions are studied. A number of interface parameters are examined, including optimum operating voltage, voltage energy, maximum power and current limits, and maximum open circuit voltage. The effect of array degradation and I-V curve fill factor or the array power conditioner interface is also discussed. Results are presented as normalized ratios of power conditioner parameters to array parameters, making the results universally applicable to a wide variety of system sizes, sites, and operating modes.
NASA Astrophysics Data System (ADS)
Liu, Jia; Li, Jing; Zhang, Zhong-ping
2013-04-01
In this article, a fatigue damage parameter is proposed to assess the multiaxial fatigue lives of ductile metals based on the critical plane concept: Fatigue crack initiation is controlled by the maximum shear strain, and the other important effect in the fatigue damage process is the normal strain and stress. This fatigue damage parameter introduces a stress-correlated factor, which describes the degree of the non-proportional cyclic hardening. Besides, a three-parameter multiaxial fatigue criterion is used to correlate the fatigue lifetime of metallic materials with the proposed damage parameter. Under the uniaxial loading, this three-parameter model reduces to the recently developed Zhang's model for predicting the uniaxial fatigue crack initiation life. The accuracy and reliability of this three-parameter model are checked against the experimental data found in literature through testing six different ductile metals under various strain paths with zero/non-zero mean stress.
Body mass index, immune status, and virological control in HIV-infected men who have sex with men.
Blashill, Aaron J; Mayer, Kenneth H; Crane, Heidi M; Grasso, Chris; Safren, Steven A
2013-01-01
Prior cross-sectional studies have found inconsistent relationships between body mass index (BMI) and disease progression in HIV-infected individuals. Cross-sectional and longitudinal analyses were conducted on data from a sample of 864 HIV-infected men who have sex with men (MSM) obtained from a large, nationally distributed HIV clinical cohort. Of the 864 HIV-infected MSM, 394 (46%) were of normal weight, 363 (42%) were overweight, and 107 (12%) were obese at baseline. The baseline CD4 count was 493 (standard error [SE] = 9), with viral load (log10) = 2.4 (SE = .04), and 561 (65%) were virologically suppressed. Over time, controlling for viral load, highly active antiretroviral therapy (HAART) adherence, age, and race/ethnicity, overweight and obese HIV-infected men possessed higher CD4 counts than that of normal weight HIV-infected men. Further, overweight and obese men possessed lower viral loads than that of normal weight HIV-infected men. For HIV-infected MSM, in this longitudinal cohort study, possessing a heavier than normal BMI is longitudinally associated with improved immunological health.
Ximénez, Carmen
2016-01-01
This article extends previous research on the recovery of weak factor loadings in confirmatory factor analysis (CFA) by exploring the effects of adding the mean structure. This issue has not been examined in previous research. This study is based on the framework of Yung and Bentler (1999) and aims to examine the conditions that affect the recovery of weak factor loadings when the model includes the mean structure, compared to analyzing the covariance structure alone. A simulation study was conducted in which several constraints were defined for one-, two-, and three-factor models. Results show that adding the mean structure improves the recovery of weak factor loadings and reduces the asymptotic variances for the factor loadings, particularly for the models with a smaller number of factors and a small sample size. Therefore, under certain circumstances, modeling the means should be seriously considered for covariance models containing weak factor loadings. PMID:26779071
CA-45 AND Sr-85 METABOLISM IN MAN. Progress Report for June 15, 1959- May 20, 1960
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
1960-10-31
Bone formation rate in a normal, healthy, young adult was observed to be 0.521 g calcium/day. Calcium balance and bone formation and destruction rates were studied in patients with disuse osetoporosis associated with quadriplegia secondary to poliomyelitis and patients with senile and posmenopausal osteoporosis. Renal strontium/calcium discrimination, studied for nine cases, was given by a mean factor of 4.3. This factor means that, exposed to trace amounts of strontium and normal calcium loads, the human kidney will produce a urine containing 4.3 atoms of strontium per unit filtered strontium for each atom calcium per unit filtered calcium. The mean valuemore » for gastrointestinal discrimination between endogenously secreted Sr/sup 85/ and Ca/sup 45/ was 1.4. The ratio of strontium-determined pool to calcium- determined pool was 1.04 plus or minus 0.13 (1 S.D.) and the corresponding ratio for bone formation values was 1.04 plus or minus 0.32 (1 S.D.) for nine patients studied. (C.J.G.)« less
NASA Astrophysics Data System (ADS)
Caliman, R.
2017-08-01
The purpose of this paper is to highlight a number of factors that influence the physical-mechanical and tribological characteristics of sintered composite materials. Such factors are grouped generally in two categories: technological parameters (pressure compacting, sintering temperature, sintering duration, heat treatment) and the receipt of sintered composite materials. In this paper is presented a program of experiments developed both in composite materials sintered polymer matrix (non-metallic) and in the metal matrix (eg., Al) which was prepared in advance a methodology original production and research for this particular type of materials. The experiments have focused development and testing of a number of 14 polymer composite and 5 composite sintered Al base, in both situations armed with carbon fiber in various forms. Tribological tests followed the establishment of the coefficient of friction and wear rate of the sliding speed at the constant values (v = 7.2 mm/s) and the normal load (N = 8 daN) and for different orientations of the fibers to the direction of sliding: normal (N type), parallel (P) and antiparallel-perpendicular (AP type).
Kim, Stanley E; Pozzi, Antonio; Banks, Scott A; Conrad, Bryan P; Lewis, Daniel D
2010-04-01
To assess contact mechanics and 3-dimensional (3-D) joint alignment in cranial cruciate ligament (CCL)-deficient stifles before and after tibial plateau leveling osteotomy (TPLO) and tibial tuberosity advancement (TTA) with the stifle in 90 degrees of flexion. In vitro biomechanical study. Cadaveric pelvic limb pairs (n=8) from dogs weighing 28-35 kg. Contralateral limbs were assigned to receive TPLO or TTA. Digital pressure sensors were used to measure femorotibial contact area, peak and mean contact pressure, and peak pressure location with the limb under a load of 30% body weight and stifle flexion angle of 90 degrees . 3-D poses were obtained using a Microscribe digitizer. Specimens were tested under normal, CCL deficient, and treatment conditions. Significant disturbances in alignment were not observed after CCL transection, although medial contact area was 10% smaller than normal (P=.003). There were no significant differences in contact mechanics or alignment between normal and TTA conditions; TPLO induced 6 degrees varus angulation (P<.001), 26% decrease in lateral peak pressure (P=.027), and 18% increase in medial mean pressure (P=.008) when compared with normal. Cranial tibial subluxation is nominal in CCL-deficient stifles loaded in flexion. Stifle alignment and contact mechanics are not altered by TTA, whereas TPLO causes mild varus and a subsequent increase in medial compartment loading. Cranial tibial subluxation of CCL-deficient stifles may not occur during postures that load the stifle in flexion. The significance of minor changes in loading patterns after TPLO is unknown.
NASA Technical Reports Server (NTRS)
Leybold, H. A.
1971-01-01
Random numbers were generated with the aid of a digital computer and transformed such that the probability density function of a discrete random load history composed of these random numbers had one of the following non-Gaussian distributions: Poisson, binomial, log-normal, Weibull, and exponential. The resulting random load histories were analyzed to determine their peak statistics and were compared with cumulative peak maneuver-load distributions for fighter and transport aircraft in flight.
A 100-kW metal wind turbine blade basic data, loads and stress analysis
NASA Technical Reports Server (NTRS)
Cherritt, A. W.; Gaidelis, J. A.
1975-01-01
A rotor loads computer program was used to define the steady state and cyclic loads acting on 60 ft long metal blades designed for the ERDA/NASA 100 kW wind turbine. Blade load and stress analysis used to support the structural design are presented. For the loading conditions examined, the metal blades are structurally adequate for use, within the normal operating range, as part of the wind turbine system.
An alternative method for centrifugal compressor loading factor modelling
NASA Astrophysics Data System (ADS)
Galerkin, Y.; Drozdov, A.; Rekstin, A.; Soldatova, K.
2017-08-01
The loading factor at design point is calculated by one or other empirical formula in classical design methods. Performance modelling as a whole is out of consideration. Test data of compressor stages demonstrates that loading factor versus flow coefficient at the impeller exit has a linear character independent of compressibility. Known Universal Modelling Method exploits this fact. Two points define the function - loading factor at design point and at zero flow rate. The proper formulae include empirical coefficients. A good modelling result is possible if the choice of coefficients is based on experience and close analogs. Earlier Y. Galerkin and K. Soldatova had proposed to define loading factor performance by the angle of its inclination to the ordinate axis and by the loading factor at zero flow rate. Simple and definite equations with four geometry parameters were proposed for loading factor performance calculated for inviscid flow. The authors of this publication have studied the test performance of thirteen stages of different types. The equations are proposed with universal empirical coefficients. The calculation error lies in the range of plus to minus 1,5%. The alternative model of a loading factor performance modelling is included in new versions of the Universal Modelling Method.
Tomaszewski, P. K.; Verdonschot, N.; Bulstra, S. K.
2010-01-01
An alternative solution to conventional stump–socket prosthetic limb attachment is offered by direct skeletal fixation. This study aimed to assess two percutaneous trans-femoral implants, the OPRA system (Integrum AB, Göteborg, Sweden), and the ISP Endo/Exo prosthesis (ESKA Implants AG, Lübeck, Germany) on bone failure and stem–bone interface mechanics both early post-operative (before bony ingrowth) and after full bone ingrowth. Moreover, mechanical consequences of implantation of those implants in terms of changed loading pattern within the bone and potential consequences on long-term bone remodeling were studied using finite-element models that represent the intact femur and implants fitted in amputated femora. Two experimentally measured loads from the normal walking cycle were applied. The analyses revealed that implantation of percutaneous prostheses had considerable effects on stress and strain energy density levels in bone. This was not only caused by the implant itself, but also by changed loading conditions in the amputated leg. The ISP design promoted slightly more physiological strain energy distribution (favoring long-term bone maintenance), but the OPRA design generated lower bone stresses (reducing bone fracture risk). The safety factor against mechanical failure of the two percutaneous designs was relatively low, which could be improved by design optimization of the implants. PMID:20309731
NASA Astrophysics Data System (ADS)
Patel, Z.; Berlin, J.; Abidi, W.
2018-02-01
One of the drugs used to treat ovarian cancer is cisplatin. However, cisplatin kills normal surrounding tissue in addition to cancer cells. To improve tumor targeting efficiency, our lab uses neural stem cells (NSCs), which migrate directly to ovarian tumors. If free cisplatin is loaded into NSCs for targeted drug delivery, it will kill the NSCs. To prevent the drug cisplatin from killing both the NSCs and normal surrounding tissue, our lab synthesizes silica nanoparticles (SiNPs) that act as a protective carrier. The big picture here is to maximize efficiency of tumor targeting using NSCs and minimize toxicity to these NSCs using SiNPs. The goal of this project is to optimize the stability of SiNPs, which is important for efficient drug loading. To do this, the concentration of tetraethyl orthosilicate (TEOS), one of the main components of SiNPs, was varied. We hypothesized that more TEOS equates to more stable SiNPs because TEOS contributes carbon to SiNPs, and thus a tightly-packed chemical structure results in a stable particle. Then, the stability of the SiNPs were checked in cell media and phosphate buffered saline (PBS). Lastly, the SiNPs were analyzed for their porosity using the transmission electron microscope (TEM). TEM imaging showed white spots in the 200-800 μL TEOS batches and no white spots in the 1000-1800 μL TEOS batches. The white spots were pores, which indicate instability. We concluded that the ultimate factor that determines the stability of SiNPs (100 nm) is the concentration of organic substance.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lopez, A.L.; Kohrs, M.B.; Horwitz, D.L.
To determine the effect of glucose loading on serum zinc concentrations, 34 elderly subjects aged 60-86 y were studied. Anthropometric data, medical and dietary histories were obtained. Serum zinc and glucose concentrations were obtained fasting and 1/2, 1, 1 1/2, 2 and 3 h after 75 g oral glucose load; glycohemoglobin and fasting serum lipids were also determined. For comparison, the subjects were categorized as: normal or low serum zinc concentrations; normal or high body mass index BMI; normal or high sum of skinfolds and normal or high serum cholesterol. Results showed that low serum zinc concentrations increased significantly overmore » baseline values after the glucose load and did not return to fasting levels. On the other hand, mean serum zinc concentrations significantly declined without recovery for those with normal zinc values. For the total group, no significant differences were noted between fasting values and subsequent time periods. No correlations were noted between fasting serum zinc and area under the curve for zinc except in the high BMI group (positive correlation observed). For the high BMI group, fasting serum zinc differed significantly from the succeeding measurements except for 30 min. For the group as a whole, mean serum zinc concentration was within normal limits (76.9 +/- 2.8 mcg/ml): mean zinc intake was less than 2/3rds the RDA. They conclude that glucose ingestion may alter serum zinc and should be considered in interpreting these levels.« less
Tribological performance of monolithic copper thin films during nanowear
Schultz, Bradley M.; Li, Nan; Economy, David R.; ...
2017-10-07
Mathematical models suggest that the strain along the film formed by parallel passes of a nanoindentation probe in contact with the film can be either homogenous or heterogeneous, depending on contact pressure and spacing between passes. Here, in this study, a 1 µm copper thin film was worn with a cono-spherical diamond probe with normal loads ranging from 25 to 800 µN and wear box edge lengths of 40, 60, and 80 µm. The nanoindenter counterface was rastered across the surface to mimic dry sliding wear. To determine potential strain field changes, 10-step quasi-static indents (200–2000 µN) were performed usingmore » nanoindentation inside the wear boxes created at various loads to determine if a strain field alteration could be observed in changes in hardness of the copper thin film. It was shown that there was a softening effect in the hardness for normal loads < 400 µN used during nanowear compared to the as-deposited copper. Normal loads ≥ 400 µN had a similar or higher hardness than the as-deposited copper. This is believed to have occurred due to a relaxation in the residual stresses created during deposition in the copper thin films at lower loads, which caused a decrease in hardness. Conversely, at the higher loads, increased deformation leads to an increase in hardness. Lastly, all of the wear boxes displayed a higher estimated strain hardening exponent than the as-deposited material.« less
Code of Federal Regulations, 2010 CFR
2010-01-01
... STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Structure Vertical Surfaces § 23.443 Gust loads. (a) Vertical surfaces must be designed to withstand, in unaccelerated flight at speed V C... computed as follows: ER09FE96.000 Where— Lvt=Vertical surface loads (lbs.); ER09FE96.001 ER09FE96.002 Ude...
Code of Federal Regulations, 2012 CFR
2012-01-01
... STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Structure Vertical Surfaces § 23.443 Gust loads. (a) Vertical surfaces must be designed to withstand, in unaccelerated flight at speed V C... computed as follows: ER09FE96.000 Where— Lvt=Vertical surface loads (lbs.); ER09FE96.001 ER09FE96.002 Ude...
Code of Federal Regulations, 2014 CFR
2014-01-01
... STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Structure Vertical Surfaces § 23.443 Gust loads. (a) Vertical surfaces must be designed to withstand, in unaccelerated flight at speed V C... computed as follows: ER09FE96.000 Where— Lvt=Vertical surface loads (lbs.); ER09FE96.001 ER09FE96.002 Ude...
Code of Federal Regulations, 2013 CFR
2013-01-01
... STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Structure Vertical Surfaces § 23.443 Gust loads. (a) Vertical surfaces must be designed to withstand, in unaccelerated flight at speed V C... computed as follows: ER09FE96.000 Where— Lvt=Vertical surface loads (lbs.); ER09FE96.001 ER09FE96.002 Ude...
Code of Federal Regulations, 2011 CFR
2011-01-01
... STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Structure Vertical Surfaces § 23.443 Gust loads. (a) Vertical surfaces must be designed to withstand, in unaccelerated flight at speed V C... computed as follows: ER09FE96.000 Where— Lvt=Vertical surface loads (lbs.); ER09FE96.001 ER09FE96.002 Ude...
Zhang, Xueyu; Zheng, Shaokui; Zhang, Hangyu; Duan, Shoupeng
2018-04-30
This study clarified the dominant nitrogen (N)-transformation pathway and the key ammonia-oxidizing microbial species at three loading levels during optimization of the anoxic/oxic (A/O) process for sewage treatment. Comprehensive N-transformation activity analysis showed that ammonia oxidization was performed predominantly by aerobic chemolithotrophic and heterotrophic ammonia oxidization, whereas N 2 production was performed primarily by anoxic denitrification in the anoxic unit. The abundances of ammonia-oxidizing bacteria (AOB), nitrite-oxidizing bacteria, and anaerobic AOB in activated sludge reflected their activities on the basis of high-throughput sequencing data. AOB amoA gene clone libraries revealed that the predominant AOB species in sludge samples shifted from Nitrosomonas europaea (61% at the normal loading level) to Nitrosomonas oligotropha (58% and 81% at the two higher loading levels). Following isolation and sequencing, the predominant culturable heterotrophic AOB in sludge shifted from Agrobacterium tumefaciens (42% at the normal loading level) to Acinetobacter johnsonii (52% at the highest loading level). Copyright © 2018 Elsevier Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
Castles, Walter, Jr.; Durham, Howard L., Jr.; Kevorkian, Jirair
1959-01-01
Values of the normal component of induced velocity throughout the entire field of a uniformly loaded r(rotor at high high speed are presented in the form of charts and tables. Many points were found by an electromagnetic analog, details of which are given. Comparisons of computed and analog values for the induced velocity indicate that the latter are sufficiently accurate for engineering purposes.
Hashemi, Mohadeseh; Yadegari, Amir; Yazdanpanah, Ghasem; Omidi, Meisam; Jabbehdari, Sayena; Haghiralsadat, Fatemeh; Yazdian, Fatemeh; Tayebi, Lobat
2017-05-01
Graphene oxide (GO) has been recently introduced as a suitable anticancer drug carrier, which could be loaded with doxorubicin (DOX) as a general chemotherapy agent. Herein, the attempts were made to optimize the effective parameters on both loading and release of DOX on GO. GO and GO-DOX were characterized using transition electron microscopy , zeta potential, Raman spectroscopy, UV-visible spectroscopy, and Fourier transform infrared spectroscopy. In addition, loading and releasing behaviors of DOX on GO were studied in terms of different temperature and pH values. The primary optimized values of pH and temperature for best-loaded amount of DOX were 8.9 and 309 K, respectively. Moreover, we found that the smallest amount of released DOX, in pH of cancer microenvironment (5.4), occurs when DOX had been previously loaded in pH 7.8 and 310 K. Although the highest amount of loaded DOX was in basic pH, the results of efficient release of DOX from the GO-DOX complex and also cellular toxicity assay revealed that the best pH for loading of DOX on GO was 7.8. Therefore, in addition to optimization of parameters for efficient loading of DOX on GO, this study suggested that normalization of a released drug compared with the amount of a loaded drug could be a new approach for optimization of drug loading on nanocarriers. © 2016 International Union of Biochemistry and Molecular Biology, Inc.
Attention and Working Memory in Adolescents with Autism Spectrum Disorder: A Functional MRI Study.
Rahko, Jukka S; Vuontela, Virve A; Carlson, Synnöve; Nikkinen, Juha; Hurtig, Tuula M; Kuusikko-Gauffin, Sanna; Mattila, Marja-Leena; Jussila, Katja K; Remes, Jukka J; Jansson-Verkasalo, Eira M; Aronen, Eeva T; Pauls, David L; Ebeling, Hanna E; Tervonen, Osmo; Moilanen, Irma K; Kiviniemi, Vesa J
2016-06-01
The present study examined attention and memory load-dependent differences in the brain activation and deactivation patterns between adolescents with autism spectrum disorders (ASDs) and typically developing (TD) controls using functional magnetic resonance imaging. Attentional (0-back) and working memory (WM; 2-back) processing and load differences (0 vs. 2-back) were analysed. WM-related areas activated and default mode network deactivated normally in ASDs as a function of task load. ASDs performed the attentional 0-back task similarly to TD controls but showed increased deactivation in cerebellum and right temporal cortical areas and weaker activation in other cerebellar areas. Increasing task load resulted in multiple responses in ASDs compared to TD and in inadequate modulation of brain activity in right insula, primary somatosensory, motor and auditory cortices. The changes during attentional task may reflect compensatory mechanisms enabling normal behavioral performance. The inadequate memory load-dependent modulation of activity suggests diminished compensatory potential in ASD.
NASA Astrophysics Data System (ADS)
Zhou, H.; Chen, B.; Han, Z. X.; Zhang, F. Q.
2009-05-01
The study on probability density function and distribution function of electricity prices contributes to the power suppliers and purchasers to estimate their own management accurately, and helps the regulator monitor the periods deviating from normal distribution. Based on the assumption of normal distribution load and non-linear characteristic of the aggregate supply curve, this paper has derived the distribution of electricity prices as the function of random variable of load. The conclusion has been validated with the electricity price data of Zhejiang market. The results show that electricity prices obey normal distribution approximately only when supply-demand relationship is loose, whereas the prices deviate from normal distribution and present strong right-skewness characteristic. Finally, the real electricity markets also display the narrow-peak characteristic when undersupply occurs.
Xia, Jing; Nooraei, Nazanin; Kalluri, Sridhar; Edwards, Brent
2015-04-01
This study investigated whether spatial separation between talkers helps reduce cognitive processing load, and how hearing impairment interacts with the cognitive load of individuals listening in multi-talker environments. A dual-task paradigm was used in which performance on a secondary task (visual tracking) served as a measure of the cognitive load imposed by a speech recognition task. Visual tracking performance was measured under four conditions in which the target and the interferers were distinguished by (1) gender and spatial location, (2) gender only, (3) spatial location only, and (4) neither gender nor spatial location. Results showed that when gender cues were available, a 15° spatial separation between talkers reduced the cognitive load of listening even though it did not provide further improvement in speech recognition (Experiment I). Compared to normal-hearing listeners, large individual variability in spatial release of cognitive load was observed among hearing-impaired listeners. Cognitive load was lower when talkers were spatially separated by 60° than when talkers were of different genders, even though speech recognition was comparable in these two conditions (Experiment II). These results suggest that a measure of cognitive load might provide valuable insight into the benefit of spatial cues in multi-talker environments.
Wagner, Florian B; Nielsen, Peter Borch; Boe-Hansen, Rasmus; Albrechtsen, Hans-Jørgen
2018-04-01
Drinking water treatment plants based on groundwater may suffer from incomplete ammonium removal, which deteriorates drinking water quality and constrains water utilities in the operation of their plants. Ammonium is normally removed through nitrification in biological granular media filters, and recent studies have demonstrated that dosing of copper can stimulate the removal of ammonium. Here, we investigated if copper dosing could generically improve ammonium removal of biofilters, at treatment plants with different characteristics. Copper was dosed at ≤1.5 μg Cu/L to biofilters at 10 groundwater treatment plants, all of which had displayed several years of incomplete nitrification. Plants exceeded the Danish national water quality standard of 0.05 mg NH 4 + /L by a factor of 2-12. Within only 2-3 weeks of dosing, ammonium removal rates increased significantly (up to 150%). Nitrification was fully established, with ammonium effluent concentrations of <0.01 mg NH 4 + -N/L at most plants, regardless of the differences in raw water chemistry, ammonium loading rates, filter design and operation, or treatment plant configuration. However, for filters without primary filtration, it took longer time to reach complete ammonium removal than for filters receiving prefiltered water, likely due to sorption of copper to iron oxides, at plants without prefiltration. With complete ammonium removal, we subjected two plants to short-term loading rate upshifts, to examine the filters' ability to cope with loading rate variations. After 2 months of dosing and an average loading rate of 1.0 g NH 4 + -N/m 3 filter material/h, the loading rate was upshifted by 50%. Yet, a filter managed to completely remove all the influent ammonium, showing that with copper dosing the filter had extra capacity to remove ammonium even beyond its normal loading rates. Depth sampling revealed that the ammonium removal rate of the filter's upper 10 cm increased more than 7-fold from 0.67 to 4.90 g NH 4 + -N/m 3 /h, and that nitrite produced from increased ammonium oxidation was completely oxidized further to nitrate. Hence, no problems with nitrite accumulation or breakthrough occurred. Overall, copper dosing generically enhanced nitrification efficiency and allowed a range of quite different plants to meet water quality standards, even at increased loading rates. The capacity increase is highly relevant in practice, as it makes filters more robust towards sudden ammonium loading rate variations. Copyright © 2017 Elsevier Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
1973-01-01
This user's manual describes the FORTRAN IV computer program developed to compute the total vertical load, normal concentrated pressure loads, and the center of pressure of typical SRB water impact slapdown pressure distributions specified in the baseline configuration. The program prepares the concentrated pressure load information in punched card format suitable for input to the STAGS computer program. In addition, the program prepares for STAGS input the inertia reacting loads to the slapdown pressure distributions.
Time-History Data of Maneuvers Performed by an F-86A Airplane During Squadron Operational Training
NASA Technical Reports Server (NTRS)
Henderson, Campbell; Thornton, James; Mayo, Alton
1952-01-01
Preliminary results of one phase of a control-motion study program are presented in the form of plots of load factor.and angular acceleration against indicated airspeed and of time histories of several measured quantities. The results were obtained from 197 maneuvers performed by an F-86A jet-fighter airplane during normal squadron operational training. Most of the tactical maneuver8 of which the F-86A is capable were performed at pressure altitudes ranging from 0 to 32,000 feet and at indicated airspeeds ranging from 95 to 650 miles per hour.
Perceptual load in different regions of the visual scene and its relevance for driving.
Marciano, Hadas; Yeshurun, Yaffa
2015-06-01
The aim of this study was to better understand the role played by perceptual load, at both central and peripheral regions of the visual scene, in driving safety. Attention is a crucial factor in driving safety, and previous laboratory studies suggest that perceptual load is an important factor determining the efficiency of attentional selectivity. Yet, the effects of perceptual load on driving were never studied systematically. Using a driving simulator, we orthogonally manipulated the load levels at the road (central load) and its sides (peripheral load), while occasionally introducing critical events at one of these regions. Perceptual load affected driving performance at both regions of the visual scene. Critically, the effect was different for central versus peripheral load: Whereas load levels on the road mainly affected driving speed, load levels on its sides mainly affected the ability to detect critical events initiating from the roadsides. Moreover, higher levels of peripheral load impaired performance but mainly with low levels of central load, replicating findings with simple letter stimuli. Perceptual load has a considerable effect on driving, but the nature of this effect depends on the region of the visual scene at which the load is introduced. Given the observed importance of perceptual load, authors of future studies of driving safety should take it into account. Specifically, these findings suggest that our understanding of factors that may be relevant for driving safety would benefit from studying these factors under different levels of load at different regions of the visual scene. © 2014, Human Factors and Ergonomics Society.
Stenset, V; Hofoss, D; Johnsen, L; Skinningsrud, A; Berstad, A E; Negaard, A; Reinvang, I; Gjerstad, L; Fladby, T
2008-12-01
To identify possible associations between white matter lesions (WML) and cognition in patients with memory complaints, stratified in groups with normal and low cerebrospinal fluid (CSF) Abeta42 values. 215 consecutive patients with subjective memory complaints were retrospectively included. Patients were stratified into two groups with normal (n = 127) or low (n = 88) CSF Abeta42 levels (cut-off is 450 ng/l). Cognitive scores from the Mini-Mental State Examination (MMSE) and the Neurobehavioral Cognitive Status Examination (Cognistat) were used as continuous dependent variables in linear regression. WML load was used as a continuous independent variable and was scored with a visual rating scale. The regression model was corrected for possible confounding factors. WML were significantly associated with MMSE and all Cognistat subscores except language (repetition and naming) and attention in patients with normal CSF Abeta42 levels. No significant associations were observed in patients with low CSF Abeta42. WML were associated with affection of multiple cognitive domains, including delayed recall and executive functions, in patients with normal CSF Abeta42 levels. The lack of such associations for patients with low CSF Abeta42 (i.e. with evidence for amyloid deposition), suggests that amyloid pathology may obscure cognitive effects of WML.
3D-printed dimethyloxallyl glycine delivery scaffolds to improve angiogenesis and osteogenesis.
Min, Zhu; Shichang, Zhao; Chen, Xin; Yufang, Zhu; Changqing, Zhang
2015-08-01
Angiogenesis-osteogenesis coupling processes are vital in bone tissue engineering. Normal biomaterials implanted in bone defects have issues in the sufficient formation of blood vessels, especially in the central part. Single delivery of vascular endothelial growth factors (VEGF) to foci in previous studies did not show satisfactory results due to low loading doses, a short protein half-life and low efficiency. Development of a hypoxia-mimicking microenvironment for cells by local prolyl-4-hydroxylase inhibitor release, which can stabilize hypoxia-inducible factor 1α (HIF-1α) expression, is an alternative method. The aim of this study was to design a dimethyloxallyl glycine (DMOG) delivering scaffold composed of mesoporous bioactive glasses and poly(3-hydroxybutyrate-co-3-hydroxyhexanoate) polymers (MPHS scaffolds), so as to investigate whether the sustained release of DMOG promotes local angiogenesis and bone healing. The morphology and microstructure of composite scaffolds were characterized. The DMOG release patterns from scaffolds loaded with different DMOG dosages were evaluated, and the effects of DMOG delivery on human bone marrow stromal cell (hBMSC) adhesion, viability, proliferation, osteogenic differentiation and angiogenic-relative gene expressions with scaffolds were also investigated. In vivo studies were carried out to observe vascular formations and new bone ingrowth with DMOG-loaded scaffolds. The results showed that DMOG could be released in a sustained manner over 4 weeks from MPHS scaffolds and obviously enhance the angiogenesis and osteogenesis in the defects. Microfil perfusion showed a significantly increased formation of vessels in the defects with DMOG delivery. Furthermore, micro-CT imaging and fluorescence labeling indicated larger areas of bone formation for DMOG-loaded scaffolds. It is concluded that MPHS-DMOG scaffolds are promising for enhancing bone healing of osseous defects.
Moving Aerospace Structural Design Practice to a Load and Resistance Factor Approach
NASA Technical Reports Server (NTRS)
Larsen, Curtis E.; Raju, Ivatury S.
2016-01-01
Aerospace structures are traditionally designed using the factor of safety (FOS) approach. The limit load on the structure is determined and the structure is then designed for FOS times the limit load - the ultimate load. Probabilistic approaches utilize distributions for loads and strengths. Failures are predicted to occur in the region of intersection of the two distributions. The load and resistance factor design (LRFD) approach judiciously combines these two approaches by intensive calibration studies on loads and strength to result in structures that are efficient and reliable. This paper discusses these three approaches.
Comparison of interphase models for a crack in fiber reinforced composite
NASA Astrophysics Data System (ADS)
Kaw, A. K.; Selvarathinam, A. S.; Besterfield, G. H.
1992-07-01
The influence of a nonhomogeneous interphase on fracture mechanics of a fiber reinforced composite is studied. The stress intensity factor at the crack tips, maximum interfacial shear and normal stresses, maximum cleavage stress in the matrix and load diffusion along the length of the fiber are studied as a function of the fiber width, the interphase thickness, and the relative stiffness properties of the fiber, the matrix and the interphase. The normal stresses at the interface, which represents the possibility of debonding of the interface, is lowest for interphase thicknesses of the order of one-tenth of the fiber-diameter, when the crack is in the stiffer material. These normal stresses are highest at such interphase thicknesses if the crack is in the less stiffer material. The results obtained by using the nonhomogeneous interphase model are also compared with five other interphase models used in the literature for the interphase, namely the perfect, the homogeneous, the distributed uncoupled shear and normal springs, and the distributed shear springs. It is found that the trends of the above parameters as a function of interphase thickness are different for the spring and continuum models, if the crack is in a stiffer material.
Measuring cognitive load during procedural skills training with colonoscopy as an exemplar.
Sewell, Justin L; Boscardin, Christy K; Young, John Q; Ten Cate, Olle; O'Sullivan, Patricia S
2016-06-01
Few studies have investigated cognitive factors affecting learning of procedural skills in medical education. Cognitive load theory, which focuses on working memory, is highly relevant, but methods for measuring cognitive load during procedural training are not well understood. Using colonoscopy as an exemplar, we used cognitive load theory to develop a self-report instrument to measure three types of cognitive load (intrinsic, extraneous and germane load) and to provide evidence for instrument validity. We developed the instrument (the Cognitive Load Inventory for Colonoscopy [CLIC]) using a multi-step process. It included 19 items measuring three types of cognitive load, three global rating items and demographics. We then conducted a cross-sectional survey that was administered electronically to 1061 gastroenterology trainees in the USA. Participants completed the CLIC following a colonoscopy. The two study phases (exploratory and confirmatory) each lasted for 10 weeks during the 2014-2015 academic year. Exploratory factor analysis determined the most parsimonious factor structure; confirmatory factor analysis assessed model fit. Composite measures of intrinsic, extraneous and germane load were compared across years of training and with global rating items. A total of 477 (45.0%) invitees participated (116 in the exploratory study and 361 in the confirmatory study) in 154 (95.1%) training programmes. Demographics were similar to national data from the USA. The most parsimonious factor structure included three factors reflecting the three types of cognitive load. Confirmatory factor analysis verified that a three-factor model was the best fit. Intrinsic, extraneous and germane load items had high internal consistency (Cronbach's alpha 0.90, 0.87 and 0.96, respectively) and correlated as expected with year in training and global assessment of cognitive load. The CLIC measures three types of cognitive load during colonoscopy training. Evidence of validity is provided. Although CLIC items relate to colonoscopy, the development process we detail can be used to adapt the instrument for use in other learning settings in medical education. © 2016 John Wiley & Sons Ltd.
Niu, Xun; Latash, Mark L.; Zatsiorsky, Vladimir M.
2010-01-01
We studied adjustments of digit forces to changes in the friction. The subjects held a handle statically in a three-digit grasp. The friction under each digit was either high or low, resulting in eight three-element friction sets (such grasps were coined the grasps with complex friction pattern). The total load was also manipulated. It was found that digit forces were adjusted not only to the supported load and local friction, but also to friction at other digits (synergic effects). When friction under a digit was low, its tangential force decreased and the normal force increased (local effects). The synergic effects were directed to maintain the equilibrium of the handle. The relation between the individual digit forces and loads agreed with the triple-product model: fin=ki(2)ki(1)L, where fin is normal force of digit i, L is the load (newtons), ki(1) is a dimensionless coefficient representing sharing the total tangential force among the digits (Σki(1)=1.0), and ki(2) is a coefficient representing the relation between the tangential and normal forces of digit i (the overall friction equivalent, OFE). At each friction set, the central controller selected the grasping template—a three-element array of ki(2)ki(1) products—and then scaled the template with the load magnitude. PMID:17493928
Influence of Finite Element Size in Residual Strength Prediction of Composite Structures
NASA Technical Reports Server (NTRS)
Satyanarayana, Arunkumar; Bogert, Philip B.; Karayev, Kazbek Z.; Nordman, Paul S.; Razi, Hamid
2012-01-01
The sensitivity of failure load to the element size used in a progressive failure analysis (PFA) of carbon composite center notched laminates is evaluated. The sensitivity study employs a PFA methodology previously developed by the authors consisting of Hashin-Rotem intra-laminar fiber and matrix failure criteria and a complete stress degradation scheme for damage simulation. The approach is implemented with a user defined subroutine in the ABAQUS/Explicit finite element package. The effect of element size near the notch tips on residual strength predictions was assessed for a brittle failure mode with a parametric study that included three laminates of varying material system, thickness and stacking sequence. The study resulted in the selection of an element size of 0.09 in. X 0.09 in., which was later used for predicting crack paths and failure loads in sandwich panels and monolithic laminated panels. Comparison of predicted crack paths and failure loads for these panels agreed well with experimental observations. Additionally, the element size vs. normalized failure load relationship, determined in the parametric study, was used to evaluate strength-scaling factors for three different element sizes. The failure loads predicted with all three element sizes provided converged failure loads with respect to that corresponding with the 0.09 in. X 0.09 in. element size. Though preliminary in nature, the strength-scaling concept has the potential to greatly reduce the computational time required for PFA and can enable the analysis of large scale structural components where failure is dominated by fiber failure in tension.
DOT National Transportation Integrated Search
2016-06-01
Load and Resistance Factor Rating (LRFR) is a reliability-based rating procedure complementary to Load and Resistance Factor Design (LRFD). The intent of LRFR is to provide consistent reliability for all bridges regardless of in-situ condition. The p...
Song, Do Kyeong; Hong, Young Sun; Sung, Yeon-Ah; Lee, Hyejin
2017-01-01
Polycystic ovary syndrome (PCOS) is associated with insulin resistance (IR) and compensatory hyperinsulinemia. IR is recognized as a major risk factor for the development of type 2 diabetes mellitus. However, few studies have investigated IR in women with PCOS and normal glucose tolerance. The objective of this study was to evaluate IR and β-cell function in women with PCOS and normal glucose tolerance. Additionally, we sought to evaluate the usefulness of oral glucose tolerance test (OGTT)-derived IR indices in lean women with PCOS. We recruited 100 women with PCOS and normal glucose tolerance and 100 age- and BMI-matched women as controls. IR and insulin secretory indices, including the homeostasis-model assessment (HOMA)-IR, HOMA-M120, HOMA-F and the Stumvoll index, were calculated from an OGTT. Increased β-cell function was defined as>75th percentile for the HOMA-F in control women. Women with PCOS had higher values for post-load 2-hour glucose, fasting insulin, post-load 2-hour insulin, HOMA-IR, HOMA-M120, HOMA-F and lower values for the Stumvoll index than the controls (all Ps<0.05). Women with PCOS and increased β-cell function showed lower Stumvoll index values than the matched controls (P<0.05). The HOMA-F was significantly associated with the HOMA-M120 and Stumvoll index when adjusted for age and BMI in a multiple regression analysis (all Ps<0.05). The HOMA-M120 was positively correlated with triglycerides and free testosterone, and the Stumvoll index was negatively correlated with triglycerides and free testosterone in lean women with PCOS (all Ps<0.05). Women with PCOS and normal glucose tolerance showed higher IR than controls matched for age, BMI, and β-cell function. β-cell function was increased in women with PCOS when compared to the matched controls, but not when the lean subjects were compared to the matched controls separately. Therefore, early evaluation of IR in women with PCOS and normal glucose tolerance may be needed.
Hong, Young Sun; Sung, Yeon-Ah
2017-01-01
Background Polycystic ovary syndrome (PCOS) is associated with insulin resistance (IR) and compensatory hyperinsulinemia. IR is recognized as a major risk factor for the development of type 2 diabetes mellitus. However, few studies have investigated IR in women with PCOS and normal glucose tolerance. The objective of this study was to evaluate IR and β-cell function in women with PCOS and normal glucose tolerance. Additionally, we sought to evaluate the usefulness of oral glucose tolerance test (OGTT)-derived IR indices in lean women with PCOS. Methods We recruited 100 women with PCOS and normal glucose tolerance and 100 age- and BMI-matched women as controls. IR and insulin secretory indices, including the homeostasis-model assessment (HOMA)-IR, HOMA-M120, HOMA-F and the Stumvoll index, were calculated from an OGTT. Increased β-cell function was defined as>75th percentile for the HOMA-F in control women. Results Women with PCOS had higher values for post-load 2-hour glucose, fasting insulin, post-load 2-hour insulin, HOMA-IR, HOMA-M120, HOMA-F and lower values for the Stumvoll index than the controls (all Ps<0.05). Women with PCOS and increased β-cell function showed lower Stumvoll index values than the matched controls (P<0.05). The HOMA-F was significantly associated with the HOMA-M120 and Stumvoll index when adjusted for age and BMI in a multiple regression analysis (all Ps<0.05). The HOMA-M120 was positively correlated with triglycerides and free testosterone, and the Stumvoll index was negatively correlated with triglycerides and free testosterone in lean women with PCOS (all Ps<0.05). Conclusions Women with PCOS and normal glucose tolerance showed higher IR than controls matched for age, BMI, and β-cell function. β-cell function was increased in women with PCOS when compared to the matched controls, but not when the lean subjects were compared to the matched controls separately. Therefore, early evaluation of IR in women with PCOS and normal glucose tolerance may be needed. PMID:28542421
Park, Jeong Ung; Tsuchiya, Toshie
2002-07-01
The effects of different molecular weights of hyaluronic acid (HA), a major component of extracellular matrix, on gap junctional intercellular communication (GJIC) in normal human dermal fibroblasts (NHDF cells) were investigated. NHDF cells were cultured for 4 days with different molecular weights of HA and then the extent of GJIC was assessed by the scrape-loading dye transfer method, using Lucifer yellow. The area of dye transfer was greater in the dishes coated with HA than in those to which HA was added. Thus, NHDF cells cultured on surfaces coated with high molecular weight (HMW) HA (MW, 800 kDa) showed greatly enhanced GJIC. Furthermore, another aim of this study was to evaluate the effects of different molecular weights of HA on the production of FGF-2 and KGF, because both are important cytokines produced by NHDF cells. When FGF-2 and KGF cultured levels of cell extracts and media were determined by ELISA, both levels were significantly enhanced when cells were grown on plates coated with HMW HA. This finding indicated that the function of gap junction channels in NHDF cells grown on plates coated with HMW HA may promote the biosynthesis of growth factors such as FGF-2 and KGF.
14 CFR 23.525 - Application of loads.
Code of Federal Regulations, 2012 CFR
2012-01-01
... the loads corresponding to the load factors specified in § 23.527. (b) In applying the loads resulting from the load factors prescribed in § 23.527, the loads may be distributed over the hull or main float... on the seaplane during the impact is assumed to be 2/3 of the weight of the seaplane. [Doc. No. 26269...
14 CFR 23.525 - Application of loads.
Code of Federal Regulations, 2013 CFR
2013-01-01
... the loads corresponding to the load factors specified in § 23.527. (b) In applying the loads resulting from the load factors prescribed in § 23.527, the loads may be distributed over the hull or main float... on the seaplane during the impact is assumed to be 2/3 of the weight of the seaplane. [Doc. No. 26269...
14 CFR 23.525 - Application of loads.
Code of Federal Regulations, 2010 CFR
2010-01-01
... the loads corresponding to the load factors specified in § 23.527. (b) In applying the loads resulting from the load factors prescribed in § 23.527, the loads may be distributed over the hull or main float... on the seaplane during the impact is assumed to be 2/3 of the weight of the seaplane. [Doc. No. 26269...
14 CFR 23.525 - Application of loads.
Code of Federal Regulations, 2014 CFR
2014-01-01
... the loads corresponding to the load factors specified in § 23.527. (b) In applying the loads resulting from the load factors prescribed in § 23.527, the loads may be distributed over the hull or main float... on the seaplane during the impact is assumed to be 2/3 of the weight of the seaplane. [Doc. No. 26269...
The Pressure Distribution over the Wings and Tail Surfaces of a PW-9 Pursuit Airplane in Flight
NASA Technical Reports Server (NTRS)
Rhode, Richard
1931-01-01
This report presents the results of an investigation to determine (1) the magnitude and distribution of aerodynamic loads over the wings and tail surfaces of a pursuit-type airplane in the maneuvers likely to impose critical loads on the various subassemblies of the airplane structure. (2) To study the phenomenon of center of pressure movement and normal force coefficient variation in accelerated flight, and (3) to measure the normal accelerations at the center of gravity, wing-tip, and tail, in order to determine the nature of the inertia forces acting simultaneously with the critical aerodynamic loads. The results obtained throw light on a number of important questions involving structural design. Some of the more interesting results are discussed in some detail, but in general the report is for the purpose of making this collection of airplane-load data obtained in flight available to those interested in airplane structures.
14 CFR 23.507 - Jacking loads.
Code of Federal Regulations, 2013 CFR
2013-01-01
...) Vertical-load factor of 1.35 times the static reactions. (2) Fore, aft, and lateral load factors of 0.4 times the vertical static reactions. (b) The horizontal loads at the jack points must be reacted by...
14 CFR 23.507 - Jacking loads.
Code of Federal Regulations, 2010 CFR
2010-01-01
...) Vertical-load factor of 1.35 times the static reactions. (2) Fore, aft, and lateral load factors of 0.4 times the vertical static reactions. (b) The horizontal loads at the jack points must be reacted by...
14 CFR 23.507 - Jacking loads.
Code of Federal Regulations, 2012 CFR
2012-01-01
...) Vertical-load factor of 1.35 times the static reactions. (2) Fore, aft, and lateral load factors of 0.4 times the vertical static reactions. (b) The horizontal loads at the jack points must be reacted by...
14 CFR 23.507 - Jacking loads.
Code of Federal Regulations, 2011 CFR
2011-01-01
...) Vertical-load factor of 1.35 times the static reactions. (2) Fore, aft, and lateral load factors of 0.4 times the vertical static reactions. (b) The horizontal loads at the jack points must be reacted by...
Burger, Koert N. J.; Beulens, Joline W. J.; van der Schouw, Yvonne T.; Sluijs, Ivonne; Spijkerman, Annemieke M. W.; Sluik, Diewertje; Boeing, Heiner; Kaaks, Rudolf; Teucher, Birgit; Dethlefsen, Claus; Overvad, Kim; Tjønneland, Anne; Kyrø, Cecilie; Barricarte, Aurelio; Bendinelli, Benedetta; Krogh, Vittorio; Tumino, Rosario; Sacerdote, Carlotta; Mattiello, Amalia; Nilsson, Peter M.; Orho-Melander, Marju; Rolandsson, Olov; Huerta, José María; Crowe, Francesca; Allen, Naomi; Nöthlings, Ute
2012-01-01
Background Dietary fiber, carbohydrate quality and quantity are associated with mortality risk in the general population. Whether this is also the case among diabetes patients is unknown. Objective To assess the associations of dietary fiber, glycemic load, glycemic index, carbohydrate, sugar, and starch intake with mortality risk in individuals with diabetes. Methods This study was a prospective cohort study among 6,192 individuals with confirmed diabetes mellitus (mean age of 57.4 years, and median diabetes duration of 4.4 years at baseline) from the European Prospective Investigation into Cancer and Nutrition (EPIC). Dietary intake was assessed at baseline (1992–2000) with validated dietary questionnaires. Cox proportional hazards analysis was performed to estimate hazard ratios (HRs) for all-cause and cardiovascular mortality, while adjusting for CVD-related, diabetes-related, and nutritional factors. Results During a median follow-up of 9.2 y, 791 deaths were recorded, 306 due to CVD. Dietary fiber was inversely associated with all-cause mortality risk (adjusted HR per SD increase, 0.83 [95% CI, 0.75–0.91]) and CVD mortality risk (0.76[0.64–0.89]). No significant associations were observed for glycemic load, glycemic index, carbohydrate, sugar, or starch. Glycemic load (1.42[1.07–1.88]), carbohydrate (1.67[1.18–2.37]) and sugar intake (1.53[1.12–2.09]) were associated with an increased total mortality risk among normal weight individuals (BMI≤25 kg/m2; 22% of study population) but not among overweight individuals (P interaction≤0.04). These associations became stronger after exclusion of energy misreporters. Conclusions High fiber intake was associated with a decreased mortality risk. High glycemic load, carbohydrate and sugar intake were associated with an increased mortality risk in normal weight individuals with diabetes. PMID:22927948
Zhang, Zhenzhen; O'Neill, Marie S; Sánchez, Brisa N
2016-04-01
Factor analysis is a commonly used method of modelling correlated multivariate exposure data. Typically, the measurement model is assumed to have constant factor loadings. However, from our preliminary analyses of the Environmental Protection Agency's (EPA's) PM 2.5 fine speciation data, we have observed that the factor loadings for four constituents change considerably in stratified analyses. Since invariance of factor loadings is a prerequisite for valid comparison of the underlying latent variables, we propose a factor model that includes non-constant factor loadings that change over time and space using P-spline penalized with the generalized cross-validation (GCV) criterion. The model is implemented using the Expectation-Maximization (EM) algorithm and we select the multiple spline smoothing parameters by minimizing the GCV criterion with Newton's method during each iteration of the EM algorithm. The algorithm is applied to a one-factor model that includes four constituents. Through bootstrap confidence bands, we find that the factor loading for total nitrate changes across seasons and geographic regions.
Parameter Accuracy in Meta-Analyses of Factor Structures
ERIC Educational Resources Information Center
Gnambs, Timo; Staufenbiel, Thomas
2016-01-01
Two new methods for the meta-analysis of factor loadings are introduced and evaluated by Monte Carlo simulations. The direct method pools each factor loading individually, whereas the indirect method synthesizes correlation matrices reproduced from factor loadings. The results of the two simulations demonstrated that the accuracy of…
Alternate Design of ITER Cryostat Skirt Support System
NASA Astrophysics Data System (ADS)
Pandey, Manish Kumar; Jha, Saroj Kumar; Gupta, Girish Kumar; Bhattacharya, Avik; Jogi, Gaurav; Bhardwaj, Anil Kumar
2017-04-01
The skirt support of ITER cryostat is a support system which takes all the load of cryostat cylinder and dome during normal and operational condition. The present design of skirt support has full penetration weld joints at the bottom (shell to horizontal plate joint). To fulfil the requirements of tolerances and control the welding distortions, we have proposed to change the full penetration weld into fillet weld. A detail calculation is done to check the feasibility and structural impact due to proposed design. The calculations provide the size requirements of fillet weld. To verify the structural integrity during most severe load case, finite element analysis (FEA) has been done in line with ASME section VIII division 2 [1]. By FEA ‘Plastic Collapse’ and ‘Local Failure’ modes has been assessed. 5° sector of skirt clamp has been modelled in CATIA V5 R21 and used in FEA. Fillet weld at shell to horizontal plate joint has been modelled and symmetry boundary condition at ± 2.5° applied. ‘Elastic Plastic Analysis’ has been performed for the most severe loading case i.e. Category IV loading. The alternate design of Cryostat Skirt support system has been found safe by analysis against Plastic collapse and Local Failure Modes with load proportionality factor 2.3. Alternate design of Cryostat skirt support system has been done and validated by FEA. As per alternate design, the proposal of fillet weld has been implemented in manufacturing.
The influence of schizotypal traits on attention under high perceptual load.
Stotesbury, Hanne; Gaigg, Sebastian B; Kirhan, Saim; Haenschel, Corinna
2018-03-01
Schizophrenia Spectrum Disorders (SSD) are known to be characterised by abnormalities in attentional processes, but there are inconsistencies in the literature that remain unresolved. This article considers whether perceptual resource limitations play a role in moderating attentional abnormalities in SSD. According to perceptual load theory, perceptual resource limitations can lead to attenuated or superior performance on dual-task paradigms depending on whether participants are required to process, or attempt to ignore, secondary stimuli. If SSD is associated with perceptual resource limitations, and if it represents the extreme end of an otherwise normally distributed neuropsychological phenotype, schizotypal traits in the general population should lead to disproportionate performance costs on dual-task paradigms as a function of the perceptual task demands. To test this prediction, schizotypal traits were quantified via the Schizotypal Personality Questionnaire (SPQ) in 74 healthy volunteers, who also completed a dual-task signal detection paradigm that required participants to detect central and peripheral stimuli across conditions that varied in the overall number of stimuli presented. The results confirmed decreasing performance as the perceptual load of the task increased. More importantly, significant correlations between SPQ scores and task performance confirmed that increased schizotypal traits, particularly in the cognitive-perceptual domain, are associated with greater performance decrements under increasing perceptual load. These results confirm that attentional difficulties associated with SSD extend sub-clinically into the general population and suggest that cognitive-perceptual schizotypal traits may represent a risk factor for difficulties in the regulation of attention under increasing perceptual load.
NASA Astrophysics Data System (ADS)
Alkhatib, Mayson H.; AlBishi, Hayat M.
2013-03-01
Doxorubicin (DOX) is an anticancer drug used to treat several cancer diseases. However, it has several dose limitation aspects because of its poor bioavailability, hydrophobicity, and cytotoxicity. In this study, five nanoemulsion (NE) formulations, containing soya phosphatidylcholine/polyoxyethylenglycerol trihydroxy-stearate 40 (EU)/sodium oleate as surfactant, cholesterol (CHO) as oil phase, and Tris-HCl buffer (pH 7.22), were produced. The NE droplets morphologies of the entire blank and DOX-loaded formulations, revealed by the transmission electron microscope, were spherical. The droplet sizes of blank NEs, obtained between 2.9 and 6.4 nm, decreased significantly with the increase in the ratio of surfactant-to-oil, whereas the droplets sizes of DOX-loaded NE formulations were significantly higher and found in the range of 7.7-15.9 nm. The evaluation for both blank and DOX-loaded NE formulations proved that the NE carrier had improved the DOX efficacy and reduced its cytotoxicity. It showed that the cell growth inhibition of the breast cancer cells (MCF-7) have exceeded the commercial DOX by a factor of 1.7 with increased apoptosis activity and minimal cytotoxicity against the normal human foreskin cells (HFS). In contrast, commercial DOX was found to exhibit a significant non-selective toxicity against both MCF-7 and HFS cells. In conclusion, we have developed DOX-loaded NE formulations which selectively and significantly inhibited cell proliferation of MCF-7 cells and increased apoptosis.
Duong, Tu Van; Van Humbeeck, Jan; Van den Mooter, Guy
2015-07-06
The reproducibility and consistency of physicochemical properties and pharmaceutical performance are major concerns during preparation of solid dispersions. The crystallization kinetics of drug/polyethylene glycol solid dispersions, an important factor that is governed by the properties of both drug and polymer has not been adequately explored, especially in systems containing high drug loadings. In this paper, by using standard and modulated differential scanning calorimetry and X-ray powder diffraction, we describe the influence of drug loading on crystallization behavior of dispersions made up of indomethacin and polyethylene glycol 6000. Higher drug loading increases the amorphicity of the polymer and inhibits the crystallization of PEG. At 52% drug loading, polyethylene glycol was completely transformed to the amorphous state. To the best of our knowledge, this is the first detailed investigation of the solubilization effect of a low molecular weight drug on a semicrystalline polymer in their dispersions. In mixtures containing up to 55% indomethacin, the dispersions exhibited distinct glass transition events resulting from amorphous-amorphous phase separation which generates polymer-rich and drug-rich domains upon the solidification of supercooled polyethylene glycol, whereas samples containing at least 60% drug showed a single amorphous phase during the period in which crystallization normally occurs. The current study demonstrates a wide range in physicochemical properties of drug/polyethylene glycol solid dispersions as a result of the complex nature in crystallization of this system, which should be taken into account during preparation and storage.
Microstructure and tribological properties of TiAg intermetallic compound coating
NASA Astrophysics Data System (ADS)
Guo, Chun; Chen, Jianmin; Zhou, Jiansong; Zhao, Jierong; Wang, Linqian; Yu, Youjun; Zhou, Huidi
2011-10-01
TiAg intermetallic compound coating has been in situ synthesized successfully on pure Ti substrate by laser cladding using Ag powder as the precursor. It has been found that the prepared coating mainly comprised TiAg and Ti phases. The high resolution transmission electron microscopy results further conform the existence of TiAg intermetallic compound in the prepared coating. The magnified high resolution transmission electron microscopy images shown that the laser cladding coating contains TiAg nanocrystalline with the size of about 4 nm. Tribological properties of the prepared TiAg intermetallic compound coating were systematically evaluated. It was found that the friction coefficient and wear rate was closely related to the normal load and sliding speed, i.e., the friction coefficient of the prepared TiAg intermetallic compound coating decreased with increasing normal load and sliding speed. The wear rate of the TiAg intermetallic compound coating decreased rapidly with increasing sliding speed, while the wear rate increased as the normal load increased.
NASA Astrophysics Data System (ADS)
Loiseau, Jason; Georges, William; Frost, David; Higgins, Andrew
2015-06-01
The incidence angle of a detonation wave is often assumed to weakly influence the terminal velocity of an explosively driven flyer. For explosives heavily loaded with dense additives, this may not be true due to differences in momentum and energy transfer between detonation products, additive particles, and the flyer. For tangential incidence the particles are first accelerated against the flyer via an expansion fan, whereas they are first accelerated by the detonation wave in the normal case. In the current study we evaluate the effect of normal versus tangential incidence on the acceleration of flyers by nitromethane heavily loaded with a variety of additives. Normal detonation was initiated via an explosively driven slapper. Flyer acceleration was measured with heterodyne laser interferometry (PDV). The influence of wave angle is evaluated by comparing the terminal velocity in the two cases (i.e., normal and grazing) for the heavily loaded mixtures. The decrement in flyer velocity correlated primarily with additive volume fraction and had a weak dependence on additive density or particle size. The Gurney energy of the heterogeneous explosive was observed to increase with flyer mass, presumably due to the timescale over which impinging particles could transfer momentum.
Kohara, Yumi; Kawaguchi, Shinichiro; Kuwahara, Rika; Uchida, Yutaro; Oku, Yushi; Yamashita, Kimihiro
2015-03-01
Cognitive dysfunction due to higher blood glucose level has been reported previously. Genistein (GEN) is a phytoestrogen that we hypothesized might lead to improved memory, despite elevated blood glucose levels at the time of memory consolidation. To investigate this hypothesis, we compared the effects of orally administered GEN on the central nervous system in normal versus glucose-loaded adult male rats. A battery of behavioral assessments was carried out. In the MAZE test, which measured spatial learning and memory, the time of normal rats was shortened by GEN treatment compared to the vehicle group, but only in the early stages of testing. In the glucose-loaded group, GEN treatment improved performance as mazes were advanced. In the open-field test, GEN treatment delayed habituation to the new environment in normal rats, and increased the exploratory behaviors of glucose-loaded rats. There were no significant differences observed for emotionality or fear-motivated learning and memory. Together, these results indicate that GEN treatment improved spatial learning and memory only in the early stages of testing in the normal state, but improved spatial learning and memory when glucose levels increased during memory consolidation. Copyright © 2014 Elsevier Inc. All rights reserved.
Dwivedi, Dipankar; Mohanty, Binayak P.; Lesikar, Bruce J.
2013-01-01
Microbes have been identified as a major contaminant of water resources. Escherichia coli (E. coli) is a commonly used indicator organism. It is well recognized that the fate of E. coli in surface water systems is governed by multiple physical, chemical, and biological factors. The aim of this work is to provide insight into the physical, chemical, and biological factors along with their interactions that are critical in the estimation of E. coli loads in surface streams. There are various models to predict E. coli loads in streams, but they tend to be system or site specific or overly complex without enhancing our understanding of these factors. Hence, based on available data, a Bayesian Neural Network (BNN) is presented for estimating E. coli loads based on physical, chemical, and biological factors in streams. The BNN has the dual advantage of overcoming the absence of quality data (with regards to consistency in data) and determination of mechanistic model parameters by employing a probabilistic framework. This study evaluates whether the BNN model can be an effective alternative tool to mechanistic models for E. coli loads estimation in streams. For this purpose, a comparison with a traditional model (LOADEST, USGS) is conducted. The models are compared for estimated E. coli loads based on available water quality data in Plum Creek, Texas. All the model efficiency measures suggest that overall E. coli loads estimations by the BNN model are better than the E. coli loads estimations by the LOADEST model on all the three occasions (three-fold cross validation). Thirteen factors were used for estimating E. coli loads with the exhaustive feature selection technique, which indicated that six of thirteen factors are important for estimating E. coli loads. Physical factors included temperature and dissolved oxygen; chemical factors include phosphate and ammonia; biological factors include suspended solids and chlorophyll. The results highlight that the LOADEST model estimates E. coli loads better in the smaller ranges, whereas the BNN model estimates E. coli loads better in the higher ranges. Hence, the BNN model can be used to design targeted monitoring programs and implement regulatory standards through TMDL programs. PMID:24511166
Padulo, Johnny; Di Giminiani, Riccardo; Dello Iacono, Antonio; Zagatto, Alessandro M; Migliaccio, Gian M; Grgantov, Zoran; Ardigò, Luca P
2016-01-01
We investigated the electromyographic response to synchronous indirect-localized vibration interventions in international and national table tennis players. Twenty-six male table tennis players, in a standing position, underwent firstly an upper arms maximal voluntary contraction and thereafter two different 30-s vibration interventions in random order: high acceleration load (peak acceleration = 12.8 g, frequency = 40 Hz; peak-to-peak displacement = 4.0 mm), and low acceleration load (peak acceleration = 7.2 g, frequency = 30 Hz, peak-to-peak displacement = 4.0 mm). Surface electromyography root mean square from brachioradialis, extensor digitorum, flexor carpi radialis, and flexor digitorum superficialis recorded during the two vibration interventions was normalized to the maximal voluntary contraction recording. Normalized surface electromyography root mean square was higher in international table tennis players with respect to national ones in all the interactions between muscles and vibration conditions (P < 0.05), with the exception of flexor carpi radialis (at low acceleration load, P > 0.05). The difference in normalized surface electromyography root mean square between international table tennis players and national ones increased in all the muscles with high acceleration load (P < 0.05), with the exception of flexor digitorum superficialis (P > 0.05). The muscle activation during indirect-localized vibration seems to be both skill level and muscle dependent. These results can optimize the training intervention in table tennis players when applying indirect-localized vibration to lower arm muscles. Future investigations should discriminate between middle- and long-term adaptations in response to specific vibration loads.
Padulo, Johnny; Di Giminiani, Riccardo; Dello Iacono, Antonio; Zagatto, Alessandro M.; Migliaccio, Gian M.; Grgantov, Zoran; Ardigò, Luca P.
2016-01-01
We investigated the electromyographic response to synchronous indirect-localized vibration interventions in international and national table tennis players. Twenty-six male table tennis players, in a standing position, underwent firstly an upper arms maximal voluntary contraction and thereafter two different 30-s vibration interventions in random order: high acceleration load (peak acceleration = 12.8 g, frequency = 40 Hz; peak-to-peak displacement = 4.0 mm), and low acceleration load (peak acceleration = 7.2 g, frequency = 30 Hz, peak-to-peak displacement = 4.0 mm). Surface electromyography root mean square from brachioradialis, extensor digitorum, flexor carpi radialis, and flexor digitorum superficialis recorded during the two vibration interventions was normalized to the maximal voluntary contraction recording. Normalized surface electromyography root mean square was higher in international table tennis players with respect to national ones in all the interactions between muscles and vibration conditions (P < 0.05), with the exception of flexor carpi radialis (at low acceleration load, P > 0.05). The difference in normalized surface electromyography root mean square between international table tennis players and national ones increased in all the muscles with high acceleration load (P < 0.05), with the exception of flexor digitorum superficialis (P > 0.05). The muscle activation during indirect-localized vibration seems to be both skill level and muscle dependent. These results can optimize the training intervention in table tennis players when applying indirect-localized vibration to lower arm muscles. Future investigations should discriminate between middle- and long-term adaptations in response to specific vibration loads. PMID:27378948
Knee Joint Loading during Gait in Healthy Controls and Individuals with Knee Osteoarthritis
Kumar, Deepak; Manal, Kurt T.; Rudolph, Katherine S.
2013-01-01
Objective People with knee osteoarthritis (OA) are thought to walk with high loads at the knee which are yet to be quantfied using modeling techniques that account for subject specific EMG patterns, kinematics and kinetics. The objective was to estimate medial and lateral loading for people with knee OA and controls using an approach that is sensitive to subject specific muscle activation patterns. Methods 16 OA and 12 control (C) subjects walked while kinematic, kinetic and EMG data were collected. Muscle forces were calculated using an EMG-Driven model and loading was calculated by balancing the external moments with internal muscle and contact forces Results OA subjects walked slower and had greater laxity, static and dynamic varus alignment, less flexion and greater knee adduction moment (KAM). Loading (normalized to body weight) was no different between the groups but OA subjects had greater absolute medial load than controls and maintained a greater %total load on the medial compartment. These patterns were associated with body mass, sagittal and frontal plane moments, static alignment and close to signficance for dynamic alignment. Lateral compartment unloading during mid-late stance was observed in 50% of OA subjects. Conclusions Loading for control subjects was similar to data from instrumented prostheses. Knee OA subjects had high medial contact loads in early stance and half of the OA cohort demonstared lateral compartment lift-off. Results suggest that interventions aimed at reducing body weight and dynamic malalignment might be effective in reducing medial compartment loading and establishing normal medio-lateral load sharing patterns. PMID:23182814
Investigation of fretting behaviour in pressure armour layers of flexible pipes
NASA Astrophysics Data System (ADS)
Don Rasika Perera, Solangarachchige
The incidence of fretting damage in the pressure armour wires of flexible pipes used in offshore oil explorations has been investigated. A novel experimental facility which is capable of simulating nub and valley contact conditions of interlocking wire winding with dynamic slip, representative of actual pipe loading, has been developed. The test set-up is equipped with a state of the art data acquisition system and a controller with transducers to measure and control the normal load, slip amplitude and friction force at the contact, in addition to the hoop stress in the wire. Tests were performed with selected loading and the fretted regions were examined using optical microscopy techniques. Results show that the magnitude of contact loading and the slip amplitude have a distinct influence on surface damage. Surface cracks originated from a fretting scar were observed at high contact loads in mixed slip sliding while surface damage predominantly due to wear was observed under gross slip. The position of surface cracks and the wear profile have been related to the contact pressure distribution. The evolution of friction force and surface damage under different slip and normal pressure conditions has been analysed. A fracture mechanics based numerical procedure has been developed to analyse the fretting damage behaviour. A severity parameter is proposed in order to ascertain whether the crack growth is in mode I or mode II cracking. The analysis show the influence of mode II cracking in the early stages of crack growth following which the crack deviates in the mode I direction making mode I the dominant crack propagation mechanism. The crack path determined by the numerical procedure correlates well with the experimental results. A numerical analysis was carried out for the fretting fatigue condition where a cyclic bulk stress superimposes with the friction force. The analysis correlates well with short crack growth behaviour. The analysis confirms that fretting is a significant factor that should be taken into account in design and operation of the pressure armour wires of flexible pipes at high contact pressure if the bulk cyclic load superimposes with the friction force. As predicted by the numerical procedure and further by experimental investigations, the surface cracks initiating on the wire in this condition are self arresting after propagating into a certain depth.
NASA Astrophysics Data System (ADS)
Primeaux, Philip A.; Zhang, Bin; Zhang, Xiaoman; Miller, Jacob; Meng, W. J.; KC, Pratik; Moore, Arden L.
2017-02-01
Microscale fin array structures were replicated onto surfaces of aluminum 1100 and aluminum 6061 alloy (Al1100/Al6061) sheet metals through room-temperature instrumented roll molding. Aluminum-based micro fin arrays were replicated at room temperature, and the fabrication process is one with high throughput and low cost. One-dimensional (1D) micro fin arrays were made through one-pass rolling, while two-dimensional (2D) micro fin arrays were made by sequential 90° cross rolling with the same roller sleeve. For roll molding of 1D micro fins, fin heights greater than 600 µm were achieved and were shown to be proportional to the normal load force per feature width. At a given normal load force, the fin height was further shown to scale inversely with the hardness of the sheet metal. For sequential 90° cross rolling, morphologies of roll molded 2D micro fin arrays were examined, which provided clues to understand how plastic deformation occurred under cross rolling conditions. A series of pool boiling experiments on low profile Al micro fin array structures were performed within Novec 7100, a widely used commercial dielectric coolant. Results for both horizontal and vertical surface orientations show that roll molded Al micro fin arrays can increase heat flux at fixed surface temperature as compared to un-patterned Al sheet. The present results further suggest that many factors beyond just increased surface area can influence heat transfer performance, including surface finish and the important multiphase transport mechanisms in and around the fin geometry. These factors must also be considered when designing and optimizing micro fin array structures for heat transfer applications.
Nivala, Michael; Song, Zhen; Weiss, James N.; Qu, Zhilin
2015-01-01
In heart failure (HF), T-tubule (TT) disruption contributes to dyssynchronous calcium (Ca) release and impaired contraction, but its role in arrhythmogenesis remains unclear. In this study, we investigate the mechanisms of TT disruption and other HF remodeling factors on Ca alternans in ventricular myocytes using computer modeling. A ventricular myocyte model with detailed spatiotemporal Ca cycling modeled by a coupled Ca release unit (CRU) network was used, in which the L-type Ca channels and the ryanodine receptor (RyR) channels were simulated by random Markov transitions. TT disruption, which removes the L-type Ca channels from the associated CRUs, results in “orphaned” RyR clusters and thus provides increased opportunity for spark-induced Ca sparks to occur. This effect combined with other HF remodeling factors promoted alternans by two distinct mechanisms: 1) for normal sarco-endoplasmic reticulum Ca ATPase (SERCA) activity, alternans was caused by both CRU refractoriness and coupling. The increased opportunity for spark-induced sparks by TT disruption combined with the enhanced CRU coupling by Ca elevation in the presence or absence of increased RyR leakiness facilitated spark synchronization on alternate beats to promote Ca alternans; 2) for down-regulated SERCA, alternans was caused by the sarcoplasmic reticulum (SR) Ca load-dependent mechanism, independent of CRU refractoriness. TT disruption and increased RyR leakiness shifted and steepened the SR Ca release-load relationship, which combines with down-regulated SERCA to promote Ca alternans. In conclusion, the mechanisms of Ca alternans for normal and down-regulated SERCA are different, and TT disruption promotes Ca alternans by both mechanisms, which may contribute to alternans at different stages of HF. PMID:25450613
Nivala, Michael; Song, Zhen; Weiss, James N; Qu, Zhilin
2015-02-01
In heart failure (HF), T-tubule (TT) disruption contributes to dyssynchronous calcium (Ca) release and impaired contraction, but its role in arrhythmogenesis remains unclear. In this study, we investigate the effects of TT disruption and other HF remodeling factors on Ca alternans in ventricular myocytes using computer modeling. A ventricular myocyte model with detailed spatiotemporal Ca cycling modeled by a coupled Ca release unit (CRU) network was used, in which the L-type Ca channels and the ryanodine receptor (RyR) channels were simulated by random Markov transitions. TT disruption, which removes the L-type Ca channels from the associated CRUs, results in "orphaned" RyR clusters and thus provides increased opportunity for spark-induced Ca sparks to occur. This effect combined with other HF remodeling factors promoted alternans by two distinct mechanisms: 1) for normal sarco-endoplasmic reticulum Ca ATPase (SERCA) activity, alternans was caused by both CRU refractoriness and coupling. The increased opportunity for spark-induced sparks by TT disruption combined with the enhanced CRU coupling by Ca elevation in the presence or absence of increased RyR leakiness facilitated spark synchronization on alternate beats to promote Ca alternans; 2) for down-regulated SERCA, alternans was caused by the sarcoplasmic reticulum (SR) Ca load-dependent mechanism, independent of CRU refractoriness. TT disruption and increased RyR leakiness shifted and steepened the SR Ca release-load relationship, which combines with down-regulated SERCA to promote Ca alternans. In conclusion, the mechanisms of Ca alternans for normal and down-regulated SERCA are different, and TT disruption promotes Ca alternans by both mechanisms, which may contribute to alternans at different stages of HF. Copyright © 2014 Elsevier Ltd. All rights reserved.
Sub-discretized surface model with application to contact mechanics in multi-body simulation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Johnson, S; Williams, J
2008-02-28
The mechanics of contact between rough and imperfectly spherical adhesive powder grains are often complicated by a variety of factors, including several which vary over sub-grain length scales. These include several traction factors that vary spatially over the surface of the individual grains, including high energy electron and acceptor sites (electrostatic), hydrophobic and hydrophilic sites (electrostatic and capillary), surface energy (general adhesion), geometry (van der Waals and mechanical), and elasto-plastic deformation (mechanical). For mechanical deformation and reaction, coupled motions, such as twisting with bending and sliding, as well as surface roughness add an asymmetry to the contact force which invalidatesmore » assumptions for popular models of contact, such as the Hertzian and its derivatives, for the non-adhesive case, and the JKR and DMT models for adhesive contacts. Though several contact laws have been offered to ameliorate these drawbacks, they are often constrained to particular loading paths (most often normal loading) and are relatively complicated for computational implementation. This paper offers a simple and general computational method for augmenting contact law predictions in multi-body simulations through characterization of the contact surfaces using a hierarchically-defined surface sub-discretization. For the case of adhesive contact between powder grains in low stress regimes, this technique can allow a variety of existing contact laws to be resolved across scales, allowing for moments and torques about the contact area as well as normal and tangential tractions to be resolved. This is especially useful for multi-body simulation applications where the modeler desires statistical distributions and calibration for parameters in contact laws commonly used for resolving near-surface contact mechanics. The approach is verified against analytical results for the case of rough, elastic spheres.« less
Contribution of tibiofemoral joint contact to net loads at the knee in gait.
Walter, Jonathan P; Korkmaz, Nuray; Fregly, Benjamin J; Pandy, Marcus G
2015-07-01
Inverse dynamics analysis is commonly used to estimate the net loads at a joint during human motion. Most lower-limb models of movement represent the knee as a simple hinge joint when calculating muscle forces. This approach is limited because it neglects the contributions from tibiofemoral joint contact forces and may therefore lead to errors in estimated muscle forces. The aim of this study was to quantify the contributions of tibiofemoral joint contact loads to the net knee loads calculated from inverse dynamics for multiple subjects and multiple gait patterns. Tibiofemoral joint contact loads were measured in four subjects with instrumented implants as each subject walked at their preferred speed (normal gait) and performed prescribed gait modifications designed to treat medial knee osteoarthritis. Tibiofemoral contact loads contributed substantially to the net knee extension and knee adduction moments in normal gait with mean values of 16% and 54%, respectively. These findings suggest that knee-contact kinematics and loads should be included in lower-limb models of movement for more accurate determination of muscle forces. The results of this study may be used to guide the development of more realistic lower-limb models that account for the effects of tibiofemoral joint contact at the knee. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.
Calibration of the live load factor in LRFD design guidelines.
DOT National Transportation Integrated Search
2010-09-01
The Load and Resistant Factor Design (LRFD) approach is based on the concept of structural reliability. The approach is : more rational than the former design approaches such as Load Factor Design or Allowable Stress Design. The LRFD : Specification ...
Calibration of the live load factor in LRFD design guidelines : [revised].
DOT National Transportation Integrated Search
2011-07-01
The Load and Resistant Factor Design (LRFD) approach is based on the concept of structural reliability. The approach is : more rational than the former design approaches such as Load Factor Design or Allowable Stress Design. The LRFD : Specification ...
A program for the calculation of paraboloidal-dish solar thermal power plant performance
NASA Technical Reports Server (NTRS)
Bowyer, J. M., Jr.
1985-01-01
A program capable of calculating the design-point and quasi-steady-state annual performance of a paraboloidal-concentrator solar thermal power plant without energy storage was written for a programmable calculator equipped with suitable printer. The power plant may be located at any site for which a histogram of annual direct normal insolation is available. Inputs required by the program are aperture area and the design and annual efficiencies of the concentrator; the intercept factor and apparent efficiency of the power conversion subsystem and a polynomial representation of its normalized part-load efficiency; the efficiency of the electrical generator or alternator; the efficiency of the electric power conditioning and transport subsystem; and the fractional parasitic loses for the plant. Losses to auxiliaries associated with each individual module are to be deducted when the power conversion subsystem efficiencies are calculated. Outputs provided by the program are the system design efficiency, the annualized receiver efficiency, the annualized power conversion subsystem efficiency, total annual direct normal insolation received per unit area of concentrator aperture, and the system annual efficiency.
Space Station laboratory module power loading analysis
NASA Astrophysics Data System (ADS)
Fu, S. J.
1994-07-01
The electrical power system of Space Station Freedom is an isolated electrical power generation and distribution network designed to meet the demands of a large number of electrical loads. An algorithm is developed to determine the power bus loading status under normal operating conditions to ensure the supply meets demand. The probabilities of power availability for payload operations (experiments) are also derived.
NASA Technical Reports Server (NTRS)
Klein, M.; Reynolds, J.; Ricks, E.
1989-01-01
Load and stress recovery from transient dynamic studies are improved upon using an extended acceleration vector in the modal acceleration technique applied to structural analysis. Extension of the normal LTM (load transformation matrices) stress recovery to automatically compute margins of safety is presented with an application to the Hubble space telescope.
ERIC Educational Resources Information Center
de Liano, Beatriz Gil-Gomez; Umilta, Carlo; Stablum, Franca; Tebaldi, Francesca; Cantagallo, Anna
2010-01-01
A reduction in congruency effects under working memory (WM) load has been previously described using different attentional paradigms (e.g., Kim, Kim, & Chun, 2005; Smilek, Enns, Eastwood, & Merikle, 2006). One hypothesis is that different types of WM load have different effects on attentional selection, depending on whether a specific memory load…
A gravity loading countermeasure skinsuit
NASA Astrophysics Data System (ADS)
Waldie, James M.; Newman, Dava J.
2011-04-01
Despite the use of several countermeasures, significant physiological deconditioning still occurs during long duration spaceflight. Bone loss - primarily due to the absence of loading in microgravity - is perhaps the greatest challenge to resolve. This paper describes a conceptual Gravity Loading Countermeasure Skinsuit (GLCS) that induces loading on the body to mimic standing and - when integrated with other countermeasures - exercising on Earth. Comfort, mobility and other operational issues were explored during a pilot study carried out in parabolic flight for prototype suits worn by three subjects. Compared to the 1- or 2-stage Russian Pingvin Suits, the elastic mesh of the GLCS can create a loading regime that gradually increases in hundreds of stages from the shoulders to the feet, thereby reproducing the weight-bearing regime normally imparted by gravity with much higher resolution. Modelling shows that the skinsuit requires less than 10 mmHg (1.3 kPa) of compression for three subjects of varied gender, height and mass. Negligible mobility restriction and excellent comfort properties were found during the parabolic flights, which suggests that crewmembers should be able to work normally, exercise or sleep while wearing the suit. The suit may also serve as a practical 1 g harness for exercise countermeasures and vibration applications to improve dynamic loading.
Gil-Gómez de Liaño, Beatriz; Umiltà, Carlo; Stablum, Franca; Tebaldi, Francesca; Cantagallo, Anna
2010-12-01
A reduction in congruency effects under working memory (WM) load has been previously described using different attentional paradigms (e.g., Kim, Kim, & Chun, 2005; Smilek, Enns, Eastwood, & Merikle, 2006). One hypothesis is that different types of WM load have different effects on attentional selection, depending on whether a specific memory load demands resources in common with target or distractor processing. In particular, if information in WM is related to the distractors in the selective attention task, there is a reduction in distraction (Kim et al., 2005). However, although previous results seem to point to a decrease in interference under high WM load conditions (Kim et al., 2005), the lack of a neutral baseline for the congruency effects makes it difficult to differentiate between a decrease in interference or in facilitation. In the present work we included neutral trials in the task introduced by Kim et al. (2005) and tested normal participants and traumatic brain injury patients. Results support a reduction in the processing of distractors under WM load, at least for incongruent trials in both groups. Theoretical as well as applied implications are discussed. Copyright © 2010 Elsevier Inc. All rights reserved.
Jin, Minfei; Chen, Ying; Zhou, Yun; Mei, Yan; Liu, Wei; Pan, Chenhao; Hua, Xiaolin
2016-04-05
Pelvic floor dysfunction (PFD) is a group of clinical conditions including stress urinary incontinence (SUI) and pelvic organ prolapse (POP). The abnormality of collagen and elastin metabolism in pelvic connective tissues is implicated in SUI and POP. To reconstitute the connective tissues with normal distribution of collagen and elastin, we transduced elastin to bone marrow-derived mesenchymal stem cells (BMSC). Elastin-expressing BMSCs were then differentiated to fibroblasts using bFGF, which produced collagen and elastin. To achieve the sustained release of bFGF, we formulated bFGF in poly (lactic-co-glycolic acid) (PLGA) nanoparticles (NP). In an in vitro cell culture system of 7 days, when no additional bFGF was administrated, the initial PLGA-loaded bFGF NP induced prolonged production of collagen and elastin from elastin-expressing BMSCs. In vivo, co-injection of PLGA-loaded bFGF NP and elastin-expressing BMSCs into the PFD rats significantly improved the outcome of urodynamic tests. Together, these results provided an efficient model of connective tissue engineering using BMSC and injectable PLGA-loaded growth factors. Our results provided the first instance of a multidisciplinary approach, combining both stem cell and nanoparticle technologies, for the treatment of PFD.
The effects of Hurricane Hugo on suspended-sediment loads, Lago Loiza Basin, Puerto Rico
Gellis, A.
1993-01-01
In the two main tributaries that enter Lago Loiza, Rio Grande de Loiza and Rio Gurabo, 99 600 tonnes of suspended sediment was transported by 58.2??106 m3 of runoff in a 48 h period. The storm-average suspended-sediment concentration in the Rio Grande de Loiza for Hurricane Hugo was 2290 mgl-1, the second lowest for the 12 storms that have been monitored at this site. In Rio Gurabo the storm-average suspended-sediment concentration was 1420 mg l -1, the sixth lowest recorded out of 15 monitored storms. In Quebrada Salvatierra, a small tributary to Rio Grande de Loiza, suspended-sediment concentrations were as low as 33 mg l-1 during peak runoff of 20m3s-1. Normally the suspended-sediment concentrations at this discharge are 300 mg l-1. Hurricane force winds seem to be the most important factor contributing to the lower than expected suspended-sediment loads. High winds caused vegetation and debris to be dislodged and displaced. Debris accumulated on hillslopes and in small channels, blocked bridges and formed debris dams. These dams caused local backwater effects that reduced stream velocities and decreased suspended-sediment loads. -from Author
Load estimator (LOADEST): a FORTRAN program for estimating constituent loads in streams and rivers
Runkel, Robert L.; Crawford, Charles G.; Cohn, Timothy A.
2004-01-01
LOAD ESTimator (LOADEST) is a FORTRAN program for estimating constituent loads in streams and rivers. Given a time series of streamflow, additional data variables, and constituent concentration, LOADEST assists the user in developing a regression model for the estimation of constituent load (calibration). Explanatory variables within the regression model include various functions of streamflow, decimal time, and additional user-specified data variables. The formulated regression model then is used to estimate loads over a user-specified time interval (estimation). Mean load estimates, standard errors, and 95 percent confidence intervals are developed on a monthly and(or) seasonal basis. The calibration and estimation procedures within LOADEST are based on three statistical estimation methods. The first two methods, Adjusted Maximum Likelihood Estimation (AMLE) and Maximum Likelihood Estimation (MLE), are appropriate when the calibration model errors (residuals) are normally distributed. Of the two, AMLE is the method of choice when the calibration data set (time series of streamflow, additional data variables, and concentration) contains censored data. The third method, Least Absolute Deviation (LAD), is an alternative to maximum likelihood estimation when the residuals are not normally distributed. LOADEST output includes diagnostic tests and warnings to assist the user in determining the appropriate estimation method and in interpreting the estimated loads. This report describes the development and application of LOADEST. Sections of the report describe estimation theory, input/output specifications, sample applications, and installation instructions.
Psychometric properties of a scale to measure alexithymia.
Blanchard, E B; Arena, J G; Pallmeyer, T P
1981-01-01
Four studies were conducted on a sample of 230 undergraduates to determine the psychometric properties of a measure of alexithymia, the Schalling-Sifneos Scale. In the first study it was found that scores on the scale are approximately normally distributed for each sex with 8.2% of males and 1.8% of females in the alexithymia range. In the second study a factor analysis of the scale revealed three distinct factors: (1) 'difficulty in expression of feelings'; (2) 'the importance of feelings especially about people'; (3) 'day-dreaming or introspection'. In the second factor analytic study, scores from several standard psychological tests on the same subjects were introduced with the scale items. Two factors in this analysis were comprised almost entirely of the other test scores: a 'general psychological distress factor' and a 'concerns about physical symptoms factor'. The other two factors were similar to factors 1 and 2 above in terms of items. The Rathus Assertiveness Scale loaded positively on the equivalent of factor 1. In the lst study, it was shown that Schalling-Sifneos Scale score is relatively orthogonal to other psychological tests with the exception of a Psychosomatic Symptom Checklist and thus is measuring something other than depression, anxiety, etc.
Research notes : customized live-load factors for bridge load rating.
DOT National Transportation Integrated Search
2007-03-01
The state-of-the-art approach to load rating bridges is the Load and Resistance Factor Rating (LRFR) method, supported by the Federal Highway Administration and the American Association of State Highway and Transportation Officials. This approach ens...
NASA Technical Reports Server (NTRS)
Kussner, H G; Thalau, Karl
1933-01-01
Load factors and loading conditions are presented for German aircraft. Loading conditions under various stress factors are presented along with a breakdown of individual aircraft components such as landing gear, wings, etc.
Exploratory factor analysis of the functional movement screen in elite athletes.
Li, Yongming; Wang, Xiong; Chen, Xiaoping; Dai, Boyi
2015-01-01
The functional movement screen is developed to examine individuals' movement patterns through 7 functional tasks. The purpose of this study was to identify the internal consistency and factor structure of the 7 tasks of the functional movement screen in elite athletes; 290 elite athletes from a variety of Chinese national teams were assessed using the functional movement screen. Cronbach's alpha was calculated for the scores of the 7 tasks. Exploratory factor analysis was performed to explore the factor structure of the functional movement screen. The mean and standard deviation of the sum score were 15.2 ± 3.0. A low Cronbach's alpha (0.58) was found for the scores of the 7 tasks. Exploratory factor analysis extracted 2 factors with eigenvalues greater than 1, and these 2 factors explained 47.3% of the total variance. The first factor had a high loading on the rotatory stability (loading = 0.99) and low loadings on the other 6 tasks (loading range: 0.04-0.34). The second factor had high loadings on the deep squat, hurdle step and inline lunge (loading range: 0.46-0.61) and low loadings on the other 3 tasks (loading range: 0.12-0.32). The 7 tasks of the functional movement screen had low internal consistency and were not indicators of a single factor. Evidence for unidimensionality was not found for the functional movement screen in elite athletes. More attention should be paid to the score of each task rather than the sum score when we interpret the functional movement screen scores.
Estimation of stress relaxation time for normal and abnormal breast phantoms using optical technique
NASA Astrophysics Data System (ADS)
Udayakumar, K.; Sujatha, N.
2015-03-01
Many of the early occurring micro-anomalies in breast may transform into a deadliest cancer tumor in future. Probability of curing early occurring abnormalities in breast is more if rightly identified. Even in mammogram, considered as a golden standard technique for breast imaging, it is hard to pick up early occurring changes in the breast tissue due to the difference in mechanical behavior of the normal and abnormal tissue when subjected to compression prior to x-ray or laser exposure. In this paper, an attempt has been made to estimate the stress relaxation time of normal and abnormal breast mimicking phantom using laser speckle image correlation. Phantoms mimicking normal breast is prepared and subjected to precise mechanical compression. The phantom is illuminated by a Helium Neon laser and by using a CCD camera, a sequence of strained phantom speckle images are captured and correlated by the image mean intensity value at specific time intervals. From the relation between mean intensity versus time, tissue stress relaxation time is quantified. Experiments were repeated for phantoms with increased stiffness mimicking abnormal tissue for similar ranges of applied loading. Results shows that phantom with more stiffness representing abnormal tissue shows uniform relaxation for varying load of the selected range, whereas phantom with less stiffness representing normal tissue shows irregular behavior for varying loadings in the given range.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false General. 27.471 Section 27.471 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: NORMAL CATEGORY ROTORCRAFT Strength Requirements Ground Loads § 27.471 General. (a) Loads and...
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false General. 27.471 Section 27.471 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: NORMAL CATEGORY ROTORCRAFT Strength Requirements Ground Loads § 27.471 General. (a) Loads and...
Influence of Obesity on Foot Loading Characteristics in Gait for Children Aged 1 to 12 Years
Mueller, Steffen; Carlsohn, Anja; Mueller, Juliane; Baur, Heiner; Mayer, Frank
2016-01-01
Background Overweight and obesity are increasing health problems that are not restricted to adults only. Childhood obesity is associated with metabolic, psychological and musculoskeletal comorbidities. However, knowledge about the effect of obesity on the foot function across maturation is lacking. Decreased foot function with disproportional loading characteristics is expected for obese children. The aim of this study was to examine foot loading characteristics during gait of normal-weight, overweight and obese children aged 1–12 years. Methods A total of 10382 children aged one to twelve years were enrolled in the study. Finally, 7575 children (m/f: n = 3630/3945; 7.0±2.9yr; 1.23±0.19m; 26.6±10.6kg; BMI: 17.1±2.4kg/m2) were included for (complete case) data analysis. Children were categorized to normal-weight (≥3rd and <90th percentile; n = 6458), overweight (≥90rd and <97th percentile; n = 746) or obese (>97th percentile; n = 371) according to the German reference system that is based on age and gender-specific body mass indices (BMI). Plantar pressure measurements were assessed during gait on an instrumented walkway. Contact area, arch index (AI), peak pressure (PP) and force time integral (FTI) were calculated for the total, fore-, mid- and hindfoot. Data was analyzed descriptively (mean ± SD) followed by ANOVA/Welch-test (according to homogeneity of variances: yes/no) for group differences according to BMI categorization (normal-weight, overweight, obesity) and for each age group 1 to 12yrs (post-hoc Tukey Kramer/Dunnett’s C; α = 0.05). Results Mean walking velocity was 0.95 ± 0.25 m/s with no differences between normal-weight, overweight or obese children (p = 0.0841). Results show higher foot contact area, arch index, peak pressure and force time integral in overweight and obese children (p<0.001). Obese children showed the 1.48-fold (1 year-old) to 3.49-fold (10 year-old) midfoot loading (FTI) compared to normal-weight. Conclusion Additional body mass leads to higher overall load, with disproportional impact on the midfoot area and longitudinal foot arch showing characteristic foot loading patterns. Already the feet of one and two year old children are significantly affected. Childhood overweight and obesity is not compensated by the musculoskeletal system. To avoid excessive foot loading with potential risk of discomfort or pain in childhood, prevention strategies should be developed and validated for children with a high body mass index and functional changes in the midfoot area. The presented plantar pressure values could additionally serve as reference data to identify suspicious foot loading patterns in children. PMID:26914211
Forefoot plantar pressure reduction of off-the-shelf rocker bottom provisional footwear.
Kavros, Steven J; Van Straaten, Meegan G; Coleman Wood, Krista A; Kaufman, Kenton R
2011-08-01
Increased plantar pressures have been shown to be a risk factor in ulceration of the neuropathic foot. Prescriptive footwear is a common medical treatment, yet evidence regarding the efficacy of these prescriptions is underdeveloped. The purpose of this study is to determine the off-loading properties of four provisional shoes; a rocker sole compared to a flat sole shoe with and without the addition of a 1.25 cm plastizote insert. Fifteen subjects with peripheral neuropathy and a normal longitudinal arch were recruited to compare four types of provisional (post-operative) footwear. Plantar surface foot pressures were measured while wearing a rocker sole shoe or a flat stiff sole shoe. Both shoes were worn with and without a 1.25 cm plastizote insert. Peak plantar pressures were recorded for the hallux, metatarsal heads (1-5), midfoot, and heel. The rocker sole shoe with plastizote had the best off-loading properties. While wearing this footwear, mean peak plantar pressure was 2.8 kg/cm(2) (range: 1.7 to 4.5 kg/cm(2), 50% mean reduction from flat sole shoe without plastizote) and 1.9 kg/cm(2) (range: 0.7 to 3.6 kg/cm(2), 35% mean reduction) at the five metatarsal heads and hallux, respectively. For patients with a normal longitudinal arch and forefeet, either at risk of developing an ulcer or are healing a forefoot ulcer, a provisional shoe with a rocker sole and plastizote insole provides plantar pressure reduction of the forefoot. However, when results were analyzed for the subjects individually the amount of off-loading varied. Copyright © 2011 Elsevier Ltd. All rights reserved.
Brandt-Williams, Sherry; Wigand, Cathleen; Campbell, Daniel E
2013-02-01
This study evaluated the link between watershed activities and salt marsh structure, function, and condition using spatial emergy flow density (areal empower density) in the watershed and field data from 10 tidal salt marshes in Narragansett Bay, RI, USA. The field-collected data were obtained during several years of vegetation, invertebrate, soil, and water quality sampling. The use of emergy as an accounting mechanism allowed disparate factors (e.g., the amount of building construction and the consumption of electricity) to be combined into a single landscape index while retaining a uniform quantitative definition of the intensity of landscape development. It expanded upon typical land use percentage studies by weighting each category for the intensity of development. At the RI salt marsh sites, an impact index (watershed emergy flow normalized for marsh area) showed significant correlations with mudflat infauna species richness, mussel density, plant species richness, the extent and density of dominant plant species, and denitrification potential within the high salt marsh. Over the 4-year period examined, a loading index (watershed emergy flow normalized for watershed area) showed significant correlations with nitrite and nitrate concentrations, as well as with the nitrogen to phosphorus ratios in stream discharge into the marshes. Both the emergy impact and loading indices were significantly correlated with a salt marsh condition index derived from intensive field-based assessments. Comparison of the emergy indices to calculated nitrogen loading estimates for each watershed also produced significant positive correlations. These results suggest that watershed emergy flow is a robust index of human disturbance and a potential tool for rapid assessment of coastal wetland condition.
Altered mechano-chemical environment in hip articular cartilage: effect of obesity.
Travascio, Francesco; Eltoukhy, Moataz; Cami, Sonila; Asfour, Shihab
2014-10-01
The production of extracellular matrix (ECM) components of articular cartilage is regulated, among other factors, by an intercellular signaling mechanism mediated by the interaction of cell surface receptors (CSR) with insulin-like growth factor-1 (IGF-1). In ECM, the presence of binding proteins (IGFBP) hinders IGF-1 delivery to CSR. It has been reported that levels of IGF-1 and IGFBP in obese population are, respectively, lower and higher than those found in normal population. In this study, an experimental-numerical approach was adopted to quantify the effect of this metabolic alteration found in obese population on the homeostasis of femoral hip cartilage. A new computational model, based on the mechano-electrochemical mixture theory, was developed to describe competitive binding kinetics of IGF-1 with IGFBP and CSR, and associated glycosaminoglycan (GAG) biosynthesis. Moreover, a gait analysis was carried out on obese and normal subjects to experimentally characterize mechanical loads on hip cartilage during walking. This information was deployed into the model to account for effects of physiologically relevant tissue deformation on GAG production in ECM. Numerical simulations were performed to compare GAG biosynthesis in femoral hip cartilage of normal and obese subjects. Results indicated that the lower ratio of IGF-1 to IGFBP found in obese population reduces cartilage GAG concentration up to 18 % when compared to normal population. Moreover, moderate physical activity, such as walking, has a modest beneficial effect on GAG production. The findings of this study suggest that IGF-1/IGFBP metabolic unbalance should be accounted for when considering the association of obesity with hip osteoarthritis.
NASA Astrophysics Data System (ADS)
Selvadurai, Paul A.; Glaser, Steven D.; Parker, Jessica M.
2017-03-01
Spatial variations in frictional properties on natural faults are believed to be a factor influencing the presence of slow slip events (SSEs). This effect was tested on a laboratory frictional interface between two polymethyl methacrylate (PMMA) bodies. We studied the evolution of slip and slip rates that varied systematically based on the application of both high and low normal stress (σ0=0.8 or 0.4 MPa) and the far-field loading rate (VLP). A spontaneous, frictional rupture expanded from the central, weaker, and more compliant section of the fault that had fewer asperities. Slow rupture propagated at speeds Vslow˜0.8 to 26 mm s-1 with slip rates from 0.01 to 0.2 μm s-1, resulting in stress drops around 100 kPa. During certain nucleation sequences, the fault experienced a partial stress drop, referred to as precursor detachment fronts in tribology. Only at the higher level of normal stress did these fronts exist, and the slip and slip rates mimicked the moment and moment release rates during the 2013-2014 Boso SSE in Japan. The laboratory detachment fronts showed rupture propagation speeds Vslow/VR∈ (5 to 172) × 10-7 and stress drops ˜ 100 kPa, which both scaled to the aforementioned SSE. Distributions of asperities, measured using a pressure sensitive film, increased in complexity with additional normal stress—an increase in normal stress caused added complexity by increasing both the mean size and standard deviation of asperity distributions, and this appeared to control the presence of the detachment front.
On the torsional loading of elastoplastic spheres in contact
NASA Astrophysics Data System (ADS)
Nadimi, Sadegh; Fonseca, Joana
2017-06-01
The mechanical interaction between two bodies involves normal loading in combination with tangential, torsional and rotational loading. This paper focuses on the torsional loading of two spherical bodies which leads to twisting moment. The theoretical approach for calculating twisting moment between two spherical bodies has been proposed by Lubkin [1]. Due to the complexity of the solution, this has been simplified by Deresiewicz for discrete element modelling [2]. Here, the application of a simplified model for elastoplastic spheres is verified using computational modelling. The single grain interaction is simulated in a combined finite discrete element domain. In this domain a grain can deform using a finite element formulation and can interact with other objects based on discrete element principles. For an elastoplastic model, the contact area is larger in comparison with the elastic model, under a given normal force. Therefore, the plastic twisting moment is stiffer. The results presented here are important for describing any granular system involving torsional loading of elastoplastic grains. In particular, recent research on the behaviour of soil has clearly shown the importance of plasticity on grain interaction and rearrangement.
Weigh-in-motion (WIM) data for site-specific LRFR bridge load rating.
DOT National Transportation Integrated Search
2011-08-12
The live load factors in the Load and Resistant Factor Rating (LRFR) Manual are based on load data from Ontario : thought to be representative of traffic volumes nationwide. However, in accordance with the methodology for : developing site-specific l...
40 CFR 86.1910 - How must I prepare and test my in-use engines?
Code of Federal Regulations, 2010 CFR
2010-07-01
... (including auxiliary loads such as air conditioning in the cab), normal ambient conditions, and the normal... engines? 86.1910 Section 86.1910 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... document that the owner/operator of the prospective test vehicle has a history of normally using the fuel...
Zahari, Siti Nurfaezah; Rahim, Nor Raihanah Abdull; Kamarul, Tunku
2017-01-01
The present study was conducted to examine the effects of body weight on intradiscal pressure (IDP) and annulus stress of intervertebral discs at lumbar spine. Three-dimensional finite element model of osseoligamentous lumbar spine was developed subjected to follower load of 500 N, 800 N, and 1200 N which represent the loads for individuals who are normal and overweight with the pure moments at 7.5 Nm in flexion and extension motions. It was observed that the maximum IDP was 1.26 MPa at L1-L2 vertebral segment. However, the highest increment of IDP was found at L4-L5 segment where the IDP was increased to 30% in flexion and it was more severe at extension motion reaching to 80%. Furthermore, the maximum annulus stress also occurred at the L1-L2 segment with 3.9 MPa in extension motion. However, the highest increment was also found at L4-L5 where the annulus stress increased to 17% in extension motion. Based on these results, the increase of physiological loading could be an important factor to the increment of intradiscal pressure and annulus fibrosis stress at all intervertebral discs at the lumbar spine which may lead to early intervertebral disc damage. PMID:29065672
Zahari, Siti Nurfaezah; Latif, Mohd Juzaila Abd; Rahim, Nor Raihanah Abdull; Kadir, Mohammed Rafiq Abdul; Kamarul, Tunku
2017-01-01
The present study was conducted to examine the effects of body weight on intradiscal pressure (IDP) and annulus stress of intervertebral discs at lumbar spine. Three-dimensional finite element model of osseoligamentous lumbar spine was developed subjected to follower load of 500 N, 800 N, and 1200 N which represent the loads for individuals who are normal and overweight with the pure moments at 7.5 Nm in flexion and extension motions. It was observed that the maximum IDP was 1.26 MPa at L1-L2 vertebral segment. However, the highest increment of IDP was found at L4-L5 segment where the IDP was increased to 30% in flexion and it was more severe at extension motion reaching to 80%. Furthermore, the maximum annulus stress also occurred at the L1-L2 segment with 3.9 MPa in extension motion. However, the highest increment was also found at L4-L5 where the annulus stress increased to 17% in extension motion. Based on these results, the increase of physiological loading could be an important factor to the increment of intradiscal pressure and annulus fibrosis stress at all intervertebral discs at the lumbar spine which may lead to early intervertebral disc damage.
Handling of induced hypercalcaemia in hyperthyroidism
Lim, P.; Jacob, E.; Khoo, O. T.
1969-01-01
The mean serum calcium of 13 hyperthyroid patients was found to be significantly higher than that of controls matched for sex and age, though none of the patients' values were outside the normal range. Nevertheless, these patients responded very promptly to hypercalcaemia (induced by an intravenous calcium load), and their serum calcium returned to normal much more rapidly compared with the matched controls. There was also increased retention of intravenous calcium load, possibly owing to increased calcitonin production. Calcium infusion may be useful in treating bone diseases in which increased bone resorption exceeds bone accretion. PMID:5354875
Quality factor concept in piezoceramic transformer performance description.
Mezheritsky, Alex V
2006-02-01
A new general approach based on the quality factor concept to piezoceramic transformer (PT) performance description is proposed. The system's quality factor, material elastic anisotropy, and coupling factors of the input and output sections of an electrically excited and electrically loaded PT fully characterize its resonance and near-resonance behavior. The PT efficiency, transformation ratio, and input and output power were analytically analyzed and simulated as functions of the load and frequency for the simplest classical Langevin-type and Rosen-type PT designs. A new formulation of the electrical input impedance allows one to separate the power consumed by PT from the power transferred into the load. The system's PT quality factor takes into account losses in each PT "input-output-load" functional components. The loading process is changing PT input electrical impedance on the way that under loading the minimum series impedance is increasing and the maximum parallel impedance is decreasing coincidentally. The quality-factors ratio, between the states of fully loaded and nonloaded PT, is one of the best measures of PTs dynamic performance--practically, the lower the ratio is, the better PT efficiency. A simple and effective method for the loaded PT quality factor determination is proposed. As was found, a piezoceramic with low piezoelectric anisotropy is required to provide maximum PT efficiency and higher corresponding voltage gain. Limitations on the PT output voltage and power, caused by nonlinear effects in piezoceramics, were established.
Carson, Daniel W.; Myer, Gregory D.; Hewett, Timothy E.; Heidt, Robert S.; Ford, Kevin R.
2014-01-01
Background Risk of overuse injury among athletes is high due in part to repeated loading of the lower extremities. Compared to individuals with normal arch (NA) structure, those with high (HA) or low arch (LA) may be at increased risk of specific overuse injuries, including stress fractures. A high medial longitudinal arch may result in decreased shock absorbing properties due to increased rigidity in foot mechanics. While the effect of arch structure on dynamic function has been examined in straight line walking and running, the relationship between the two during multi-directional movements remains unstudied. Objective The purpose of this study was to determine if differences in plantar loading in football players occur during both walking and pivoting movements. Method Plantar loading was examined in 9 regions of the foot for 26 participants (16 NA, 10 HA). Results High arch athletes demonstrated increased maximum force in the lateral rear foot and medial forefoot, and force time integral in the medial forefoot while walking. HA athletes also demonstrated increased maximum force in the medial rear foot and medial and central forefoot during rapid pivoting. Conclusions The current findings demonstrate that loading patterns differ between football players with high and normal arch structure, which could possibly influence injury risk in this population. PMID:23141809
Speech rate reduction and "nasality" in normal speakers.
Brancewicz, T M; Reich, A R
1989-12-01
This study explored the effects of reduced speech rate on nasal/voice accelerometric measures and nasality ratings. Nasal/voice accelerometric measures were obtained from normal adults for various speech stimuli and speaking rates. Stimuli included three sentences (one obstruent-loaded, one semivowel-loaded, and one containing a single nasal), and /pv/ syllable trains.. Speakers read the stimuli at their normal rate, half their normal rate, and as slowly as possible. In addition, a computer program paced each speaker at rates of 1, 2, and 3 syllables per second. The nasal/voice accelerometric values revealed significant stimulus effects but no rate effects. The nasality ratings of experienced listeners, evaluated as a function of stimulus and speaking rate, were compared to the accelerometric measures. The nasality scale values demonstrated small, but statistically significant, stimulus and rate effects. However, the nasality percepts were poorly correlated with the nasal/voice accelerometric measures.
Laboratory observations of fault strength in response to changes in normal stress
Kilgore, Brian D.; Lozos, Julian; Beeler, Nicholas M.; Oglesby, David
2012-01-01
Changes in fault normal stress can either inhibit or promote rupture propagation, depending on the fault geometry and on how fault shear strength varies in response to the normal stress change. A better understanding of this dependence will lead to improved earthquake simulation techniques, and ultimately, improved earthquake hazard mitigation efforts. We present the results of new laboratory experiments investigating the effects of step changes in fault normal stress on the fault shear strength during sliding, using bare Westerly granite samples, with roughened sliding surfaces, in a double direct shear apparatus. Previous experimental studies examining the shear strength following a step change in the normal stress produce contradictory results: a set of double direct shear experiments indicates that the shear strength of a fault responds immediately, and then is followed by a prolonged slip-dependent response, while a set of shock loading experiments indicates that there is no immediate component, and the response is purely gradual and slip-dependent. In our new, high-resolution experiments, we observe that the acoustic transmissivity and dilatancy of simulated faults in our tests respond immediately to changes in the normal stress, consistent with the interpretations of previous investigations, and verify an immediate increase in the area of contact between the roughened sliding surfaces as normal stress increases. However, the shear strength of the fault does not immediately increase, indicating that the new area of contact between the rough fault surfaces does not appear preloaded with any shear resistance or strength. Additional slip is required for the fault to achieve a new shear strength appropriate for its new loading conditions, consistent with previous observations made during shock loading.
14 CFR 27.787 - Cargo and baggage compartments.
Code of Federal Regulations, 2010 CFR
2010-01-01
... AIRCRAFT AIRWORTHINESS STANDARDS: NORMAL CATEGORY ROTORCRAFT Design and Construction Personnel and Cargo... for its placarded maximum weight of contents and for the critical load distributions at the... authorized weight of cargo and baggage at the critical loading distribution. (d) If cargo compartment lamps...
Code of Federal Regulations, 2010 CFR
2010-01-01
...: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Structure Control Surface and System Loads § 23.409 Tabs. Control surface tabs must be designed for the most severe combination of airspeed and tab deflection likely to be obtained within the flight envelope for any usable loading condition. ...
Design-Optimization and Material Selection for a Proximal Radius Fracture-Fixation Implant
NASA Astrophysics Data System (ADS)
Grujicic, M.; Xie, X.; Arakere, G.; Grujicic, A.; Wagner, D. W.; Vallejo, A.
2010-11-01
The problem of optimal size, shape, and placement of a proximal radius-fracture fixation-plate is addressed computationally using a combined finite-element/design-optimization procedure. To expand the set of physiological loading conditions experienced by the implant during normal everyday activities of the patient, beyond those typically covered by the pre-clinical implant-evaluation testing procedures, the case of a wheel-chair push exertion is considered. Toward that end, a musculoskeletal multi-body inverse-dynamics analysis is carried out of a human propelling a wheelchair. The results obtained are used as input to a finite-element structural analysis for evaluation of the maximum stress and fatigue life of the parametrically defined implant design. While optimizing the design of the radius-fracture fixation-plate, realistic functional requirements pertaining to the attainment of the required level of the devise safety factor and longevity/lifecycle were considered. It is argued that the type of analyses employed in the present work should be: (a) used to complement the standard experimental pre-clinical implant-evaluation tests (the tests which normally include a limited number of daily-living physiological loading conditions and which rely on single pass/fail outcomes/decisions with respect to a set of lower-bound implant-performance criteria) and (b) integrated early in the implant design and material/manufacturing-route selection process.
Single Null Negative Triangularity Tokamak for Power Handling
NASA Astrophysics Data System (ADS)
Kikuchi, Mitsuru; Medvedev, S.; Takizuka, T.; Sauter, O.; Merle, A.; Coda, S.; Chen, D.; Li, J. X.
2017-10-01
Power and particle control in fusion reactor is challenge and we proposed the negative triangularity tokamak (NTT) to eliminate ELM by operating L-mode edge with improved core confinement. The SN configuration has more flexibility in shaping by adopting rectangular-shaped TF coils. The limiting normalized beta is 3.56 with wall stabilization and 3.14 without wall. The vertical stability is assured under a reasonable control system. The wetted area on the divertor plates becomes wider in proportion to the larger major radius at the divertor strike points due to the NT configuration. In addition to the major-radius effect, the ``Flux Tune Expansion (FTE)'' is adopted to further reduce the heat load on the divertor plate by factor of 2.6 with a coil current 3 MA. L-mode edge also allows further increase in wetted area. The fusion power of 3 GW is deliverable only at normalized beta 2.1. Therefore this reactor may be operable stably against the serious MHD activities. The CD power for SS operation is 175 MW at Q = 17. AC operation is also possible option. A required HH factor is relatively modest H = 1.12.
Soboleva, L A; Shul'dyakov, A A; Bulkina, N V
2015-01-01
In order to study the clinical-pathogenetic efficacy of using cycloferon liniment in the combined therapy of patients with gingivitis on the background of chronic infectious diseases (HIV infection, hepatitis C, brucellosis), medical examination and treatment of 42 patients with this diagnosis has been carried out. It is established, that the use of cycloferon liniment in the combined therapy decreases the infection load in periodontal recess and manifestation of local inflammation, normalizes the immunity indices, and reduces the level of endogenous intoxication. All these factors provide acceleration of the recuperation processes and decrease the frequency of recidivating.
[Optimization of parodontitis treatment of patients with tuberculosis].
Aleksandrova, E A; Lepilin, A V; Kazimirova, N E; Shul'diakov, A A
2010-01-01
For the purpose to determine the clinic-pathogenetic efficacy of Cycloferon liniment in the combined therapy of parodontitis of patients with focal tuberculosis medical examination and treatment of 40 patients is carried out. It is established, that use of liniment Cycloferon in the combined treatment of patients with focal tuberculosis allows to accelerate process of normalization of lipid peroxidation parameters and antioxidant potential of blood, to decrease infection load (Herpes symplex virus I, Candida albicans, Staphylococcus aureus) in parodontal recess and evidence of local inflammation with reduction of activity of the tumours necrosis factor and interleukin 1beta, that provides acceleration of recuperation processes, lowering the frequency of parodontitis relapses.
Analysis of shear test method for composite laminates
NASA Technical Reports Server (NTRS)
Bergner, H. W., Jr.; Davis, J. G., Jr.; Herakovich, C. T.
1977-01-01
An elastic plane stress finite element analysis of the stress distributions in four flat test specimens for in-plane shear response of composite materials subjected to mechanical or thermal loads is presented. The shear test specimens investigated include: slotted coupon, cross beam, losipescu, and rail shear. Results are presented in the form of normalized shear contour plots for all three in-plane stess components. It is shown that the cross beam, losipescu, and rail shear specimens have stress distributions which are more than adequate for determining linear shear behavior of composite materials. Laminate properties, core effects, and fixture configurations are among the factors which were found to influence the stress distributions.
Niedermeier, W
1993-03-01
Tooth mobility was measured mechano-electronically with the aid of quasi-static and dynamic methods in 309 patients comprising 2650 teeth being periodontally healthy. Besides, clinical and roentgenographic findings were ascertained to relate functional features to each periodontium. In general the result was that teeth loaded excessively show increased mobility parameters compared to those loaded normally. However, the mobility of teeth loaded poorly or deficiently was even greater compared to teeth stressed excessively. Moreover, follow-up studies showed that tooth mobility decreases after removal of functional disorders of the masticatory system or an immobilisation of splinted teeth. An experimental trauma of the periodontal ligament also brings on an increased tooth mobility which decreases to the original values some days after the trial.
NASA Astrophysics Data System (ADS)
Lestari, W. D.; Ismail, R.; Jamari, J.; Bayuseno, A. P.
2017-05-01
Surface texture is a common method for improving wear properties of a tribo-pair of soft and hard bearing material. The reduction of wear rates on the contacting surface material is becoming important issues. In the present study, analysis of the contact pressure on the flat surface of UHMWPE (Ultra High Molecular Weight Polyethylene) under the static- and rolling motion with the surface of steel ball used the 3D finite element method (FEM) (the ABAQUS software version 6.12). Five shaped-texture models (square, circle, ellipse, triangle, and chevron) were presented on the flat surface for analysis. The normal load of 17, 30 and 50 N was deliberately set-up for static and rolling contact analysis. The contact pressure was determined to predict the wear behavior of the shaped-texture on the flat surface of UHMWPE. The results have shown that the static normal load yielded the lowest von-Mises stress distribution on the shaped-texture of the ellipse for all values applied a load, while the square shape experienced the highest stress distribution. Under rolling contact, however, the increasing load yielded the increasing von Mises stress distribution for the texture with a triangle shape. Moreover, the texture shapes for circle, ellipse, and chevron respectively, may undergo the lowest stress distribution for all load. The wear calculation provided that the circle and square shape may undergo the highest wear rates. Obviously, the surface texture of circle, ellipse, and chevron may experience the lowest wear rates and is potential for use in the surface engineering of bearing materials.
Ground reaction forces on stairs. Part II: knee implant patients versus normals.
Stacoff, Alex; Kramers-de Quervain, Inès A; Luder, Gerhard; List, Renate; Stüssi, Edgar
2007-06-01
The goal of this study was to compare selected parameters of vertical ground reaction forces (GRF) of good outcome patients with different prosthesis designs with a matched control group during level walking, stair ascent and descent. Forty subjects, 29 with three main implant designs (including four subjects with a passive knee flexion restriction), and 11 healthy controls were measured with 8-10 repetitions. Vertical ground reaction forces were measured during two consecutive steps with force plates embedded in the walkway and the staircase. Defined parameters of the force signals were used to compare the results of the test groups. The results show, that, postoperatively, good outcome patients produce gait patterns of the vertical ground reaction force which are comparable to normal healthy subjects with the exception of a few distinct differences: a significant reduction (p<0.05) in the vertical loading on the operated side during level walking at take-off, at weight acceptance and take-off during stair ascent of the normal stair. During stair descent, the patients did not reduce load on the operated side, but increased load variation and side-to-side asymmetry; thus, the mechanical loads on the implants were high, which may be important information with respect to loading protocols of knee implant simulators. No systematic differences in any of the test parameters were found between posterior cruciate-retaining (LCS MB and Innex CR) versus non-retaining (LCS RP and Innex UCOR) implant designs. The restricted group showed significant reductions (p<0.05) of several loading parameters as well as an increased side-to-side asymmetry. About one third of the force parameters of the good outcome patients showed a side-to-side asymmetry between two consecutive steps, which was over a proposed level of acceptance.
Marzolini, Catia; Sabin, Caroline; Raffi, François; Siccardi, Marco; Mussini, Cristina; Launay, Odile; Burger, David; Roca, Bernardino; Fehr, Jan; Bonora, Stefano; Mocroft, Amanda; Obel, Niels; Dauchy, Frederic-Antoine; Zangerle, Robert; Gogos, Charalambos; Gianotti, Nicola; Ammassari, Adriana; Torti, Carlo; Ghosn, Jade; Chêne, Genevieve; Grarup, Jesper; Battegay, Manuel
2015-01-14
The prevalence of overweight and obesity is increasing among HIV-infected patients. Whether standard antiretroviral drug dosage is adequate in heavy individuals remains unresolved. We assessed the virological and immunological responses to initial efavirenz (EFV)-containing regimens in heavy compared to normal-weight HIV-infected patients. Observational European cohort collaboration study. Eligible patients were antiretroviral-naïve with documented weight prior to EFV start and follow-up viral loads after treatment initiation. Cox regression analyses evaluated the association between weight and time to first undetectable viral load (<50 copies/ml) after treatment initiation, and time to viral load rebound (two consecutive viral load >50 copies/ml) after initial suppression over 5 years of follow-up. Recovery of CD4 cell count was evaluated 6 and 12 months after EFV initiation. Analyses were stratified by weight (kg) group (I - <55; II - >55, <80 (reference); III - >80, <85; IV - >85, <90; V - >90, <95; VI - >95). The study included 19,968 patients, of whom 9.1, 68.3, 9.1, 5.8, 3.5, and 4.3% were in weight groups I-VI, respectively. Overall, 81.1% patients attained virological suppression, of whom 34.1% subsequently experienced viral load rebound. After multiple adjustments, no statistical difference was observed in time to undetectable viral load and virological rebound for heavier individuals compared to their normal-weight counterparts. Although heaviest individuals had significantly higher CD4 cell count at baseline, CD4 cell recovery at 6 and 12 months after EFV initiation was comparable to normal-weight individuals. Virological and immunological responses to initial EFV-containing regimens were not impaired in heavy individuals, suggesting that the standard 600 mg EFV dosage is appropriate across a wide weight range.
Eye-lens accommodation load and static trapezius muscle activity.
Richter, H O; Bänziger, T; Forsman, M
2011-01-01
The purpose of this experimental study was to investigate if sustained periods of oculomotor load impacts on neck/scapular area muscle activity. The static trapezius muscle activity was assessed from bipolar surface electromyography, normalized to a submaximal contraction. Twenty-eight subjects with a mean age of 29 (range 19-42, SD 8) viewed a high-contrast fixation target for two 5-min periods through: (1) -3.5 dioptre (D) lenses; and (2) 0 D lenses. The target was placed 5 D away from the individual's near point of accommodation. Each subject's ability to compensate for the added blur was extracted via infrared photorefraction measurements. Subjects whose accommodative response was higher in the -D blur condition (1) showed relatively more static bilateral trapezius muscle activity level. During no blur (2) there were no signs of relationships. The results indicate that sustained eye-lens accommodation at near, during ergonomically unfavourable viewing conditions, could possibly represent a risk factor for trapezius muscle myalgia.
Optimization of BI test parameters to investigate mechanical properties of Grade 92 steel
NASA Astrophysics Data System (ADS)
Barbadikar, Dipika R.; Vincent, S.; Ballal, Atul R.; Peshwe, Dilip R.; Mathew, M. D.
2018-04-01
The ball indentation (BI) testing is used to evaluate the tensile properties of materials namely yield strength, strength coefficient, ultimate tensile strength, and strain hardening exponent. The properties evaluated depend on a number of BI test parameters. These parameters include the material constants like yield slope (YS), constraint factor (CF), yield offset parameter (YOP). Number of loading/unloading cycles, preload, indenter size and depth of penetration of indenter also affects the properties. In present investigation the effect of these parameters on the stress-strain curve of normalized and tempered Grade 92 steel is evaluated. Grade 92 is a candidate material for power plant application over austenitic stainless steel and derives its strength from M23C6, MX precipitates and high dislocation density. CF, YS and YOP changed the strength properties considerably. Indenter size effect resulted in higher strength for smaller indenter. It is suggested to use larger indenter diameter and higher number of loading cycles for GRADE 92 steel to get best results using BI technique.
NASA Technical Reports Server (NTRS)
1982-01-01
The device called the Power Factor Controller (PFC) offers exceptional energy conservation potential by virtue of its ability to sense shifts in the relationship between voltage and current flow, and to match them with the motor's need. Originating from the solar heating/cooling program, the PFC senses a light load, it cuts the voltage level to the minimum needed which in turn reduces current flow and heat loss. Laboratory tests showed that the PFC could reduce power used by six to eight percent under normal motor loads, and as much as 65 percent when the motor was idling. Over 150 companies have been granted NASA licenses for commercial use of this technology. One system that utilizes this technology is the Vectrol Energy System, (VES) produced by Vectrol, Inc. a subsidiary of Westinghouse. The VES is being used at Woodward & Lothrop, on their escalators. Energy use is regulated according to how many people are on the escalator at any time. It is estimated that the energy savings are between 30 to 40 percent.
Rolling Bearing Life Prediction-Past, Present, and Future
NASA Technical Reports Server (NTRS)
Zaretsky, E V; Poplawski, J. V.; Miller, C. R.
2000-01-01
Comparisons were made between the life prediction formulas of Lundberg and Palmgren, Ioannides and Harris, and Zaretsky and full-scale ball and roller bearing life data. The effect of Weibull slope on bearing life prediction was determined. Life factors are proposed to adjust the respective life formulas to the normalized statistical life distribution of each bearing type. The Lundberg-Palmgren method resulted in the most conservative life predictions compared to Ioannides and Harris, and Zaretsky methods which produced statistically similar results. Roller profile can have significant effects on bearing life prediction results. Roller edge loading can reduce life by as much as 98 percent. The resultant predicted life not only depends on the life equation used but on the Weibull slope assumed, the least variation occurring with the Zaretsky equation. The load-life exponent p of 10/3 used in the American National Standards Institute (ANSI)/American Bearing Manufacturers Association (ABMA)/International Organization for Standardization (ISO) standards is inconsistent with the majority roller bearings designed and used today.
Epstein-Barr virus in autoimmune diseases.
Toussirot, Eric; Roudier, Jean
2008-10-01
Autoimmune diseases such as systemic lupus erythematosus (SLE), rheumatoid arthritis (RA), and primary Sjögren's syndrome (pSS) are complex disorders with a genetic background and the involvement of environmental factors, including viruses. The Epstein-Barr virus (EBV) is a plausible candidate for playing a role in the pathophysiology of these diseases. Both SLE and RA are characterized by high titers of anti-EBV antibodies and impaired T-cell responses to EBV antigens. Compared with normal subjects, elevated EBV load in peripheral blood has been observed in SLE and RA. EBV DNA or RNA has been evidenced in target organs of RA (synovium) or pSS (salivary glands). Finally, molecular mimicry has been demonstrated between EBV proteins and self antigens in these three conditions. In addition, SLE, RA, and pSS are associated with an increased risk of lymphoma with a potential role for EBV. The influence of new and emergent treatments of these autoimmune diseases (biological therapies) on EBV load and the course of latent EBV infection requires further studies.
NASA Astrophysics Data System (ADS)
Loiseau, Jason; Georges, William; Frost, David L.; Higgins, Andrew J.
2017-01-01
The incidence angle of a detonation wave in a conventional high explosive influences the acceleration and terminal velocity of a metal flyer by increasing the magnitude of the material velocity imparted by the transmitted shock wave as the detonation is tilted towards normal loading. For non-ideal explosives heavily loaded with inert additives, the detonation velocity is typically subsonic relative to the flyer sound speed, leading to shockless accelerations when the detonation is grazing. Further, in a grazing detonation the particles are initially accelerated in the direction of the detonation and only gain velocity normal to the initial orientation of the flyer at later times due to aerodynamic drag as the detonation products expand. If the detonation wave in a non-ideal explosive instead strikes the flyer at normal incidence, a shock is transmitted into the flyer and the first interaction between the particle additives and the flyer occurs due to the imparted material velocity from the passage of the detonation wave. Consequently, the effect of incidence angle and additive properties may play a more prominent role in the flyer acceleration. In the present study we experimentally compared normal detonation loadings to grazing loadings using a 3-mm-thick aluminum slapper to impact-initiate a planar detonation wave in non-ideal explosive-particle admixtures, which subsequently accelerated a second 6.4-mm-thick flyer. Flyer acceleration was measured with heterodyne laser velocimetry (PDV). The explosive mixtures considered were packed beds of glass or steel particles of varying sizes saturated with sensitized nitromethane, and gelled nitromethane mixed with glass microballoons. Results showed that the primary parameter controlling changes in flyer velocity was the presence of a transmitted shock, with additive density and particle size playing only secondary roles. These results are similar to the grazing detonation experiments, however under normal loading the largest, higher density particles yielded the highest terminal flyer velocity, whereas in the grazing experiments the larger, low density particles yielded the highest terminal velocity.
Biomechanical analysis of low back load when sneezing.
Hasegawa, Tetsuya; Katsuhira, Junji; Matsudaira, Ko; Iwakiri, Kazuyuki; Maruyama, Hitoshi
2014-09-01
Although sneezing is known to induce low back pain, there is no objective data of the load generated when sneezing. Moreover, the approaches often recommended for reducing low back pain, such as leaning with both hands against a wall, are not supported by objective evidence. Participants were 12 healthy young men (mean age 23.25 ± 1.54 years) with no history of spinal column pain or low back pain. Measurements were taken using a three-dimensional motion capture system and surface electromyograms in three experimental conditions: normal for sneezing, characterized by forward trunk inclination; stand, in which the body was deliberately maintained in an upright posture when sneezing; and table, in which the participants leaned with both hands on a table when sneezing. We analyzed and compared the intervertebral disk compressive force, low back moment, ground reaction force, trunk inclination angle, and co-contraction of the rectus abdominis and erector spinae muscles in the three conditions. The intervertebral disk compressive force and ground reaction force were significantly lower in the stand and table conditions than in the normal condition. The co-contraction index value was significantly higher in the stand condition than in the normal and table conditions. When sneezing, body posture in the stand or table condition can reduce load on the low back compared with body posture in the normal sneezing condition. Thus, placing both hands on a table or otherwise maintaining an upright body posture appears to be beneficial for reducing low back load when sneezing. Copyright © 2014 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gao, Ke; Euser, Bryan J.; Rougier, Esteban
Sheared granular layers undergoing stick-slip behavior are broadly employed to study the physics and dynamics of earthquakes. In this paper, a two-dimensional implementation of the combined finite-discrete element method (FDEM), which merges the finite element method (FEM) and the discrete element method (DEM), is used to explicitly simulate a sheared granular fault system including both gouge and plate, and to investigate the influence of different normal loads on seismic moment, macroscopic friction coefficient, kinetic energy, gouge layer thickness, and recurrence time between slips. In the FDEM model, the deformation of plates and particles is simulated using the FEM formulation whilemore » particle-particle and particle-plate interactions are modeled using DEM-derived techniques. The simulated seismic moment distributions are generally consistent with those obtained from the laboratory experiments. In addition, the simulation results demonstrate that with increasing normal load, (i) the kinetic energy of the granular fault system increases; (ii) the gouge layer thickness shows a decreasing trend; and (iii) the macroscopic friction coefficient does not experience much change. Analyses of the slip events reveal that, as the normal load increases, more slip events with large kinetic energy release and longer recurrence time occur, and the magnitude of gouge layer thickness decrease also tends to be larger; while the macroscopic friction coefficient drop decreases. Finally, the simulations not only reveal the influence of normal loads on the dynamics of sheared granular fault gouge, but also demonstrate the capabilities of FDEM for studying stick-slip dynamic behavior of granular fault systems.« less
Gao, Ke; Euser, Bryan J.; Rougier, Esteban; ...
2018-06-20
Sheared granular layers undergoing stick-slip behavior are broadly employed to study the physics and dynamics of earthquakes. In this paper, a two-dimensional implementation of the combined finite-discrete element method (FDEM), which merges the finite element method (FEM) and the discrete element method (DEM), is used to explicitly simulate a sheared granular fault system including both gouge and plate, and to investigate the influence of different normal loads on seismic moment, macroscopic friction coefficient, kinetic energy, gouge layer thickness, and recurrence time between slips. In the FDEM model, the deformation of plates and particles is simulated using the FEM formulation whilemore » particle-particle and particle-plate interactions are modeled using DEM-derived techniques. The simulated seismic moment distributions are generally consistent with those obtained from the laboratory experiments. In addition, the simulation results demonstrate that with increasing normal load, (i) the kinetic energy of the granular fault system increases; (ii) the gouge layer thickness shows a decreasing trend; and (iii) the macroscopic friction coefficient does not experience much change. Analyses of the slip events reveal that, as the normal load increases, more slip events with large kinetic energy release and longer recurrence time occur, and the magnitude of gouge layer thickness decrease also tends to be larger; while the macroscopic friction coefficient drop decreases. Finally, the simulations not only reveal the influence of normal loads on the dynamics of sheared granular fault gouge, but also demonstrate the capabilities of FDEM for studying stick-slip dynamic behavior of granular fault systems.« less
Gonneaud, Julie; Kalpouzos, Grégoria; Bon, Laetitia; Viader, Fausto; Eustache, Francis; Desgranges, Béatrice
2011-01-01
Prospective memory (PM) is the ability to remember to perform an action at a specific point in the future. Regarded as multidimensional, PM involves several cognitive functions that are known to be impaired in normal aging. In the present study, we set out to investigate the cognitive correlates of PM impairment in normal aging. Manipulating cognitive load, we assessed event- and time-based PM, as well as several cognitive functions, including executive functions, working memory and retrospective episodic memory, in healthy subjects covering the entire adulthood. We found that normal aging was characterized by PM decline in all conditions and that event-based PM was more sensitive to the effects of aging than time-based PM. Whatever the conditions, PM was linked to inhibition and processing speed. However, while event-based PM was mainly mediated by binding and retrospective memory processes, time-based PM was mainly related to inhibition. The only distinction between high- and low-load PM cognitive correlates lays in an additional, but marginal, correlation between updating and the high-load PM condition. The association of distinct cognitive functions, as well as shared mechanisms with event- and time-based PM confirms that each type of PM relies on a different set of processes. PMID:21678154
Huang, Shiping
2017-11-13
The evolution of the contact area with normal load for rough surfaces has great fundamental and practical importance, ranging from earthquake dynamics to machine wear. This work bridges the gap between the atomic scale and the macroscopic scale for normal contact behavior. The real contact area, which is formed by a large ensemble of discrete contacts (clusters), is proven to be much smaller than the apparent surface area. The distribution of the discrete contact clusters and the interaction between them are key to revealing the mechanism of the contacting solids. To this end, Green's function molecular dynamics (GFMD) is used to study both how the contact cluster evolves from the atomic scale to the macroscopic scale and the interaction between clusters. It is found that the interaction between clusters has a strong effect on their formation. The formation and distribution of the contact clusters is far more complicated than that predicted by the asperity model. Ignorance of the interaction between them leads to overestimating the contacting force. In real contact, contacting clusters are smaller and more discrete due to the interaction between the asperities. Understanding the exact nature of the contact area with the normal load is essential to the following research on friction.
Evolution of the Contact Area with Normal Load for Rough Surfaces: from Atomic to Macroscopic Scales
NASA Astrophysics Data System (ADS)
Huang, Shiping
2017-11-01
The evolution of the contact area with normal load for rough surfaces has great fundamental and practical importance, ranging from earthquake dynamics to machine wear. This work bridges the gap between the atomic scale and the macroscopic scale for normal contact behavior. The real contact area, which is formed by a large ensemble of discrete contacts (clusters), is proven to be much smaller than the apparent surface area. The distribution of the discrete contact clusters and the interaction between them are key to revealing the mechanism of the contacting solids. To this end, Green's function molecular dynamics (GFMD) is used to study both how the contact cluster evolves from the atomic scale to the macroscopic scale and the interaction between clusters. It is found that the interaction between clusters has a strong effect on their formation. The formation and distribution of the contact clusters is far more complicated than that predicted by the asperity model. Ignorance of the interaction between them leads to overestimating the contacting force. In real contact, contacting clusters are smaller and more discrete due to the interaction between the asperities. Understanding the exact nature of the contact area with the normal load is essential to the following research on friction.
Irani, Yazad D; Tian, Yuan; Wang, Mengjia; Klebe, Sonja; McInnes, Steven J; Voelcker, Nicolas H; Coffer, Jeffery L; Williams, Keryn A
2015-10-01
Dysfunction of corneal epithelial stem cells can result in painful and blinding disease of the ocular surface. In such cases, treatment may involve transfer of growth factor and normal adult stem cells to the ocular surface. Our purpose was to develop an implantable scaffold for the delivery of drugs and cells to the ocular surface. We examined the potential of novel composite biomaterials fabricated from electrospun polycaprolactone (PCL) fibres into which nanostructured porous silicon (pSi) microparticles of varying sizes (150-250 μm or <40 μm) had been pressed. The PCL fabric provided a flexible support for mammalian cells, whereas the embedded pSi provided a substantial surface area for efficient delivery of adsorbed drugs and growth factors. Measurements of tensile strength of these composites revealed that the pSi did not strongly influence the mechanical properties of the polymer microfiber component for the Si loadings evaluated. Human lens epithelial cells (SRA01/04) attached to the composite materials, and exhibited enhanced attachment and growth when the materials were coated with foetal bovine serum. To examine the ability of the materials to deliver a small-drug payload, pSi microparticles were loaded with fluorescein diacetate prior to cell attachment. After 6 hours (h), cells exhibited intracellular fluorescence, indicative of transfer of the fluorescein diacetate into viable cells and its subsequent enzymatic conversion to fluorescein. To investigate loading of large-molecule biologics, murine BALB/c 3T3 cells, responsive to epidermal growth factor, insulin and transferrin, were seeded on composite materials. The cells showed significantly more proliferation at 48 h when seeded on composites loaded with these biologics, than on unloaded composites. No cell proliferation was observed on PCL alone, indicating the biologics had loaded into the pSi microparticles. Drug release, measured by ELISA for insulin, indicated a burst followed by a slower, continuous release over six days. When implanted under the rat conjunctiva, the most promising composite material did not cause significant neovascularization but did elicit a macrophage and mild foreign body response. These novel pressed pSi-PCL materials have potential for delivery of both small and large drugs that can be released in active form, and can support the growth of mammalian cells. Copyright © 2015 Elsevier Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
Monaghan, R. C.; Friend, E. L.
1973-01-01
Wind-up-turn maneuvers were performed to establish the values of airplane normal force coefficient for buffet onset, wing-rock onset, and buffet loads with various combinations of leading- and trailing-edge flap deflections. Data were gathered at both subsonic and transonic speeds covering a range from Mach 0.64 to Mach 0.92. Buffet onset and buffet loads were obtained from wingtip acceleration and wing-root bending-moment data, and wing-rock onset was obtained from airplane roll rate data. Buffet onset, wing-rock onset, and buffet loads were similarly affected by the various combinations of leading- and training-edge flaps. Subsonically, the 12 deg leading-edge-flap and trailing-edge-flap combination was most effective in delaying buffet onset, wing-rock onset, and equivalent values of buffet loads to a higher value of airplane normal force coefficient. This was the maximum flap deflection investigated. Transonically, however, the optimum leading-edge flap position was generally less than 12 deg.
Musculoskeletal disorder risk during automotive assembly: current vs. seated
Ferguson, Sue A.; Marras, William S.; Allread, W. Gary; Knapik, Gregory G.; Splittstoesser, Riley E.
2013-01-01
Musculoskeletal disorder risk was assessed during automotive assembly processes. The risk associated with current assembly processes was compared to using a cantilever chair intervention. Spine loads and normalized shoulder muscle activity were evaluated during assembly in eight regions of the vehicle. Eight interior cabin regions of the vehicle were classified by reach distance, height from vehicle floor and front to back. The cantilever chair intervention tool was most effective in the far reach regions regardless of the height. In the front far reach regions both spine loads and normalized shoulder muscle activity levels were reduced. In the middle and close reach regions spine loads were reduced, however, shoulder muscle activity was not, thus an additional intervention would be necessary to reduce shoulder risk. In the back far reach region, spine loads were not significantly different between the current and cantilever chair conditions. Thus, the effectiveness of the cantilever chair was dependent on the region of the vehicle. PMID:22036450
Some new evidence on human joint lubrication.
Unsworth, A; Dowson, D; Wright, V
1975-01-01
Theoretical consideration has been given to the use of pendulum machines which are used to examine the frictional properties of human joints by incorporating them as fulcra. As a result, a new type of pendulum machine has been built which incorporates the facility to apply sudden loads to the joint on starting the swinging motion, and also the ability to measure directly the frictional torque experienced by the joint. The results obtained from natural hip joints indicate the presence of squeeze film lubrication under conditions of sudden loading of a joint. In addition, a self-generated fluid film process was observed at low loads while at higher loads boundary lubrication appeared to be important. These results have been used to describe the lubrication regimens occurring in a normal activity such as walking. A single experiment carried out on a hip from a patient suffering from severe rheumatoid arthritis has also been reported and the frictional resistance was seen to be increased fifteenfold compared to a normal hip. Images PMID:1190847
Effect of external viscous load on head movement
NASA Technical Reports Server (NTRS)
Nam, M.-H.; Lakshminarayanan, V.; Stark, L. W.
1984-01-01
Quantitative measurements of horizontal head rotation were obtained from normal human subjects intending to make 'time optimal' trajectories between targets. By mounting large, lightweight vanes on the head, viscous damping B, up to 15 times normal could be added to the usual mechanical load of the head. With the added viscosity, the head trajectory was slowed and of larger duration (as expected) since fixed and maximal (for that amplitude) muscle forces had to accelerate the added viscous load. This decreased acceleration and velocity and longer duration movement still ensued in spite of adaptive compensation; this provided evidence that quasi-'time optimal' movements do indeed employ maximal muscle forces. The adaptation to this added load was rapid. Then the 'adapted state' subjects produced changed trajectories. The adaptation depended in part on the differing detailed instructions given to the subjects. This differential adaptation provided evidence for the existence of preprogrammed controller signals, sensitive to intended criterion, and neurologically ballistic or open loop rather than modified by feedback from proprioceptors or vision.
Detecting Tooth Damage in Geared Drive Trains
NASA Technical Reports Server (NTRS)
Nachtsheim, Philip R.
1997-01-01
This paper describes a method that was developed to detect gear tooth damage that does not require a priori knowledge of the frequency characteristic of the fault. The basic idea of the method is that a few damaged teeth will cause transient load fluctuations unlike the normal tooth load fluctuations. The method attempts to measure the energy in the lower side bands of the modulated signal caused by the transient load fluctuations. The method monitors the energy in the frequency interval which excludes the frequency of the lowest dominant normal tooth load fluctuation and all frequencies above it. The method reacted significantly to the tooth fracture damage results documented in the Lewis data sets which were obtained from tests of the OH-58A transmission and tests of high contact ratio spiral bevel gears. The method detected gear tooth fractures in all four of the high contact ratio spiral bevel gear runs. Published results indicate other detection methods were only able to detect faults for three out of four runs.
Blioumi, E; Chatzidimitriou, D; Pazartzi, Ch; Katopodi, Th; Tzimagiorgis, G; Emmanouil-Nikoloussi, E-N; Markopoulos, A; Kalekou, C; Lazaridis, N; Diza, E; Antoniades, D
2014-09-01
To evaluate the role of HPV in oral carcinogenesis, we examined the prevalence of HPV in malignant, potentially malignant and normal oral epithelium and studied the relation of HPV prevalence with other factors obtained from the patient's records. Our material consisted of 291 tissue specimens from 258 individuals. From every individual formalin fixed and paraffin embedded tissues were examined by nested Polymerase Chain Reaction (NPCR) for the detection of HPV DNA and by immunohistochemistry (IHC) for the in situ detection of HPV L1 protein. Positive PCR products were sequenced in order to type HPVs. Also 33 fresh tissues were obtained, fixed and used to detect HPV particles by transitional electron microscopy (TEM). HPV was detected in 32.9% of the tissue specimens by NPCR, in 4.7% by immunohistochemistry and in 28.1% by TEM. In detail, by nested PCR HPV L1 DNA was detected in 40% of normal tissues, 40% of fibromas, 35.8% of non-dysplastic leukoplakias, 31.6% of dysplastic leukoplakias and 22.2% of oral squamous cell carcinomas. The HPV viral load of 96.5% of the samples was very low (1 viral copy per 10(2)-10(4) cells). HPV16 prevails in all histological groups in 89-100%. We conclude that HPV does not seem, from the specific sample examined, to play a substantial role in oral carcinogenesis. However, it cannot be excluded that HPV could be involved in oral carcinogenesis only in cases with high viral load or at early stages of carcinogenesis possibly through the hit-and-run mechanism. Copyright © 2014 Elsevier Ltd. All rights reserved.
Steininger, Stefanie C.; Liu, Xinyang; Gietl, Anton; Wyss, Michael; Schreiner, Simon; Gruber, Esmeralda; Treyer, Valerie; Kälin, Andrea; Leh, Sandra; Buck, Alfred; Nitsch, Roger M.; Prüssmann, Klaas P.; Hock, Christoph; Unschuld, Paul G.
2014-01-01
Background: Deposition of cortical amyloid beta (Aβ) is a correlate of aging and a risk factor for Alzheimer disease (AD). While several higher order cognitive processes involve functional interactions between cortex and cerebellum, this study aims to investigate effects of cortical Aβ deposition on coupling within the cerebro-cerebellar system. Methods: We included 15 healthy elderly subjects with normal cognitive performance as assessed by neuropsychological testing. Cortical Aβ was quantified using (11)carbon-labeled Pittsburgh compound B positron-emission-tomography late frame signals. Volumes of brain structures were assessed by applying an automated parcelation algorithm to three dimensional magnetization-prepared rapid gradient-echo T1-weighted images. Basal functional network activity within the cerebro-cerebellar system was assessed using blood-oxygen-level dependent resting state functional magnetic resonance imaging at the high field strength of 7 T for measuring coupling between cerebellar seeds and cerebral gray matter. A bivariate regression approach was applied for identification of brain regions with significant effects of individual cortical Aβ load on coupling. Results: Consistent with earlier reports, a significant degree of positive and negative coupling could be observed between cerebellar seeds and cerebral voxels. Significant positive effects of cortical Aβ load on cerebro-cerebellar coupling resulted for cerebral brain regions located in inferior temporal lobe, prefrontal cortex, hippocampus, parahippocampal gyrus, and thalamus. Conclusion: Our findings indicate that brain amyloidosis in cognitively normal elderly subjects is associated with decreased network efficiency within the cerebro-cerebellar system. While the identified cerebral regions are consistent with established patterns of increased sensitivity for Aβ-associated neurodegeneration, additional studies are needed to elucidate the relationship between dysfunction of the cerebro-cerebellar system and risk for AD. PMID:24672483
Steininger, Stefanie C; Liu, Xinyang; Gietl, Anton; Wyss, Michael; Schreiner, Simon; Gruber, Esmeralda; Treyer, Valerie; Kälin, Andrea; Leh, Sandra; Buck, Alfred; Nitsch, Roger M; Prüssmann, Klaas P; Hock, Christoph; Unschuld, Paul G
2014-01-01
Deposition of cortical amyloid beta (Aβ) is a correlate of aging and a risk factor for Alzheimer disease (AD). While several higher order cognitive processes involve functional interactions between cortex and cerebellum, this study aims to investigate effects of cortical Aβ deposition on coupling within the cerebro-cerebellar system. We included 15 healthy elderly subjects with normal cognitive performance as assessed by neuropsychological testing. Cortical Aβ was quantified using (11)carbon-labeled Pittsburgh compound B positron-emission-tomography late frame signals. Volumes of brain structures were assessed by applying an automated parcelation algorithm to three dimensional magnetization-prepared rapid gradient-echo T1-weighted images. Basal functional network activity within the cerebro-cerebellar system was assessed using blood-oxygen-level dependent resting state functional magnetic resonance imaging at the high field strength of 7 T for measuring coupling between cerebellar seeds and cerebral gray matter. A bivariate regression approach was applied for identification of brain regions with significant effects of individual cortical Aβ load on coupling. Consistent with earlier reports, a significant degree of positive and negative coupling could be observed between cerebellar seeds and cerebral voxels. Significant positive effects of cortical Aβ load on cerebro-cerebellar coupling resulted for cerebral brain regions located in inferior temporal lobe, prefrontal cortex, hippocampus, parahippocampal gyrus, and thalamus. Our findings indicate that brain amyloidosis in cognitively normal elderly subjects is associated with decreased network efficiency within the cerebro-cerebellar system. While the identified cerebral regions are consistent with established patterns of increased sensitivity for Aβ-associated neurodegeneration, additional studies are needed to elucidate the relationship between dysfunction of the cerebro-cerebellar system and risk for AD.
Investigation of Friction and Wear Properties of Electroless Ni-P-Cu Coating Under Dry Condition
NASA Astrophysics Data System (ADS)
Duari, Santanu; Mukhopadhyay, Arkadeb; Barman, Tapan Kr.; Sahoo, Prasanta
This study presents the deposition and tribological characterization of electroless Ni-P-Cu coatings deposited on AISI 1040 steel specimens. After deposition, coatings are heat treated at 500∘C for 1h. Surface morphology study of the coatings reveals its typical cauliflower like appearance. Composition study of the coatings using energy dispersive X-ray analysis indicates that the deposit lies in the high phosphorus range. The coatings undergo crystallization on heat treatment. A significant improvement in microhardness of the coatings is also observed on heat treatment due to the precipitation of hard crystalline phases. The heat-treated coatings are subjected to sliding wear tests on a pin-on-disc type tribo-tester under dry condition by varying the applied normal load, sliding speed and sliding duration. The coefficient of friction (COF) increases with an increase in the applied normal load while it decreases with an increase in the sliding speed. The wear depth on the other hand increases with an increase in applied normal load as well as sliding speed. The worn surface morphology mainly indicates fracture of the nodules.
Fundamental concepts of structural loading and load relief techniques for the space shuttle
NASA Technical Reports Server (NTRS)
Ryan, R. S.; Mowery, D. K.; Winder, S. W.
1972-01-01
The prediction of flight loads and their potential reduction, using various control system logics for the space shuttle vehicles, is discussed. Some factors not found on previous launch vehicles that increase the complexity are large lifting surfaces, unsymmetrical structure, unsymmetrical aerodynamics, trajectory control system coupling, and large aeroelastic effects. These load-producing factors and load-reducing techniques are analyzed.
[Taurine as a regulator of fluid-electrolyte balance and arterial pressure].
Ciechanowska, B
1997-01-01
Taurine is a sulfonic beta-amino acid which occurs in the highest concentration in the brain, the retina and in the myocardium. In cardiomyocytes it presents about 50% of free amino acids and plays a role as an osmoregulator, an inotropic factor and has an antiarrhythmic property. Moreover, taurine lowers arterial pressure by extension of diuresis and by vasodilatation. Similar effect on the vascular system and arterial pressure is exerted by atrial natriuretic peptide (ANP). Increase of both ANP secretion and myocardial taurine concentration is present in the same diseases as congestive cardiac failure, hypertension and hypernatremia. The aim of the study was the evaluation of general taurine depletion, caused by making the rats drink guanidinoethyl sulfonate (GES)--an inhibitor of taurine transport affecting fluid balance and arterial pressure as well as plasma ANP concentration under normal conditions and after increase of sodium load. The 103 male Wistar rats weighing 250-300 g were used. The animals were separated into 5 groups. Control group received tap water to drink. Group II was sodium-loaded by drinking 171 mmol/l NaCl. In group III depletion of taurine was obtained by the intake of 60 mmol/l GES. Rats in group IV were drinking 60 mmol/l GES in 171 mmol/l NaCl. Group V was made to drink 200 mmol/l taurine in 171 mmol/l NaCl. All animals had standard food and were able at any time to drink. Duration of the experiment was 20 days. At the onset and after 10 and 20 days the rats were weighed and their systolic blood pressure was measured by tail plethysmography. After 10 and 20 days of the study, plasma and myocardium taurine concentration, ANP, hematocrit, plasma osmolity, natremia, kalemia, urea and creatinine concentrations were determined. Taking GES for 20 days led to 43% decrease of plasma taurine and its myocardium content about 50% as compared to control group (Tab. 2). High, statistically significant correlation (r = 0.50, p < 0.001) between myocardium taurine and plasma ANP was found. The animals with taurine depletion had significantly lower (about 30%) plasma ANP concentration (Tab. 3), higher natremia (Tab. 4) and their arterial pressure increased due to sodium load. Systolic pressure was 11 mm Hg higher in that group in comparison to control and other groups (Tab. 1). However, the sodium-loading of the rats that drank taurine solution led to an increase of hematocrit, plasma osmolity, urea concentration and body mass gain as compared to control group, but without any arterial pressure increase. The sodium-loaded rats with normal plasma and myocardium taurine concentration were affected in a similar manner. The rats with higher myocardium taurine concentration had lower heart mass index. Results of this work lead to the following conclusions: 1. Depletion of taurine in hearts of examined rats leads to a decrease of plasma atrial natriuretic peptide (ANP) concentration in plasma. 2. ANP secretion caused by salt loading is lower in animals with taurine depletion than in normal animals. 3. Sodium-loading of animals with taurine depletion leads to hypernatremia and to an increase of arterial pressure. 4. Addition of taurine to animals loaded with sodium may lead to their dehydration.
Akter, Shamima; Eguchi, Masafumi; Kurotani, Kayo; Kochi, Takeshi; Pham, Ngoc Minh; Ito, Rie; Kuwahara, Keisuke; Tsuruoka, Hiroko; Mizoue, Tetsuya; Kabe, Isamu; Nanri, Akiko
2015-02-01
Acid-base status has been suggested to influence blood pressure, but there is a paucity of epidemiologic evidence linking dietary acid load to hypertension. We examined cross-sectionally the association between dietary acid load and hypertension in a Japanese working population. Data were derived from health surveys from 2028 employees, ages 18 to 70 y, in two workplaces in Japan. A validated brief diet history questionnaire was used to assess diet. Two measures were used to characterize dietary acid load: potential renal acid load and estimated net endogenous acid production, which were derived from nutrient intakes. Multilevel logistic regression was used to examine the association between dietary acid load and hypertension with adjustment of potential confounding variables. High dietary acid load was suggestively associated with increased prevalence of hypertension. The multivariable adjusted odds ratios (95% confidence interval) of hypertension for the lowest through highest tertiles of net endogenous acid production were 1.00 (reference), 1.07 (0.80-1.42), and 1.33 (0.998-1.78), respectively (P for trend = 0.053). This positive association was statistically significant among normal-weight (body mass index <23 kg/m(2); P for trend = 0.03) and non-shift workers (P for trend = 0.04). Similar positive associations were observed between potential renal acid load and hypertension. The present findings suggest that high dietary acid load may be associated with increased prevalence of hypertension among those who were normal weight and non-shift workers. Copyright © 2015 Elsevier Inc. All rights reserved.
Excitation of plane Lamb wave in plate-like structures under applied surface loading
NASA Astrophysics Data System (ADS)
Zhou, Kai; Xu, Xinsheng; Zhao, Zhen; Yang, Zhengyan; Zhou, Zhenhuan; Wu, Zhanjun
2018-02-01
Lamb waves play an important role in structure health monitoring (SHM) systems. The excitation of Lamb waves has been discussed for a long time with absorbing results. However, little effort has been made towards the precise characterization of Lamb wave excitation by various transducer models with mathematical foundation. In this paper, the excitation of plane Lamb waves with plane strain assumption in isotropic plate structures under applied surface loading is solved with the Hamiltonian system. The response of the Lamb modes excited by applied loading is expressed analytically. The effect of applied loading is divided into the product of two parts as the effect of direction and the effect of distribution, which can be changed by selecting different types of transducer and the corresponding transducer configurations. The direction of loading determines the corresponding displacement of each mode. The effect of applied loading on the in-plane and normal directions depends on the in-plane and normal displacements at the surface respectively. The effect of the surface loading distribution on the Lamb mode amplitudes is mainly reflected by amplitude versus frequency or wavenumber. The frequencies at which the maxima and minima of the S0 or A0 mode response occur depend on the distribution of surface loading. The numerical results of simulations conducted on an infinite aluminum plate verify the theoretical prediction of not only the direction but also the distribution of applied loading. A pure S0 or A0 mode can be excited by selecting the appropriate direction and distribution at the corresponding frequency.
CANISTER TRANSFER SYSTEM DESCRIPTION DOCUMENT
DOE Office of Scientific and Technical Information (OSTI.GOV)
B. Gorpani
2000-06-23
The Canister Transfer System receives transportation casks containing large and small disposable canisters, unloads the canisters from the casks, stores the canisters as required, loads them into disposal containers (DCs), and prepares the empty casks for re-shipment. Cask unloading begins with cask inspection, sampling, and lid bolt removal operations. The cask lids are removed and the canisters are unloaded. Small canisters are loaded directly into a DC, or are stored until enough canisters are available to fill a DC. Large canisters are loaded directly into a DC. Transportation casks and related components are decontaminated as required, and empty casks aremore » prepared for re-shipment. One independent, remotely operated canister transfer line is provided in the Waste Handling Building System. The canister transfer line consists of a Cask Transport System, Cask Preparation System, Canister Handling System, Disposal Container Transport System, an off-normal canister handling cell with a transfer tunnel connecting the two cells, and Control and Tracking System. The Canister Transfer System operating sequence begins with moving transportation casks to the cask preparation area with the Cask Transport System. The Cask Preparation System prepares the cask for unloading and consists of cask preparation manipulator, cask inspection and sampling equipment, and decontamination equipment. The Canister Handling System unloads the canister(s) and places them into a DC. Handling equipment consists of a bridge crane hoist, DC loading manipulator, lifting fixtures, and small canister staging racks. Once the cask has been unloaded, the Cask Preparation System decontaminates the cask exterior and returns it to the Carrier/Cask Handling System via the Cask Transport System. After the DC is fully loaded, the Disposal Container Transport System moves the DC to the Disposal Container Handling System for welding. To handle off-normal canisters, a separate off-normal canister handling cell is located adjacent to the canister transfer cell and is interconnected to the transfer cell by means of the off-normal canister transfer tunnel. All canister transfer operations are controlled by the Control and Tracking System. The system interfaces with the Carrier/Cask Handling System for incoming and outgoing transportation casks. The system also interfaces with the Disposal Container Handling System, which prepares the DC for loading and subsequently seals the loaded DC. The system support interfaces are the Waste Handling Building System and other internal Waste Handling Building (WHB) support systems.« less
NASA Astrophysics Data System (ADS)
Strasser, Matthew N.
Structural loading produced by an impacting vortex is a hazardous phenomenon that is encountered in numerous applications ranging from the destruction of residences by tornados to the chopping of tip vortices by rotors. Adequate design of structures to resist vortex-induced structural loading necessitates study of the phenomenon that control the structural loading produced by an impacting vortex. This body of work extends the current knowledge base of vortex-structure interaction by evaluating the influence of the relative vortex-to-structure size on the structural loading that the vortex produces. A computer model is utilized to directly simulate the two-dimensional impact of an impinging vortex with a slender, cylindrical structure. The vortex's tangential velocity profile (TVP) is defined by a normalization of the Vatistas analytical (TVP) which realistically replicates the documented spectrum of measured vortex TVPs. The impinging vortex's maximum tangential velocity is fixed, and the vortex's critical radius is incremented from one to one-hundred times the structure's diameter. When the impinging vortex is small, it interacts with vortices produced on the structure by the free stream, and maximum force coefficient amplitudes vary by more than 400% when the impinging vortex impacts the structure at different times. Maximum drag and lift force coefficient amplitudes reach asymptotic values as the impinging vortex's size increases that are respectively 94.77% and 10.66% less than maximum force coefficients produced by an equivalent maximum velocity free stream. The vortex produces maximum structural loading when its path is shifted above the structure's centerline, and maximum drag and lift force coefficients are respectively up to 4.80% and 34.07% greater than maximum force coefficients produced by an equivalent-velocity free stream. Finally, the dynamic load factor (DLF) concept is used to develop a generalized methodology to assess the dynamic amplification of a structure's response to vortex loading and to assess the dynamic loading threat that tornados pose. Typical civil and residential structures will not experience significant response amplification, but responses of very flexible structures may be amplified by up to 2.88 times.
Response of Metals and Metallic Structures to Dynamic Loading
1978-05-01
materials for service by testing under high rates of loading. Impact tests such as the Charpy test, the drop-weight tear test, and the dynamic tear...have clearly shown this for precracked charpy specimens and for the drop-weight tear test. Hence, there is a strong need for additional dynamic...dynamic fracture resistance ( Charpy , dynamic-tear, drop-weight tear test, etc.), normally assures that fracture in dynamically loaded structures is
Downs, S.C.; Appel, David H.
1986-01-01
Construction of the four-lane Appalachian Corridon G highway disturbed about 2 sq mi in the Coal River and 0.35 sq mi of the 4.75 sq mi Trace Fork basin in southern West Virginia. Construction had a negligible effect on runoff and suspended-sediment load in the Coal River and its major tributaries, the Little Coal and Big Coal Rivers. Drainage areas of the mainstem sites in the Coal River basin ranged from 269 to 862 sq mi, and average annual suspended-sediment yields ranged from 535 to 614 tons/sq mi for the 1975-81 water years. Suspended-sediment load in the smaller Trace Fork basin (4.72 sq mi) was significantly affected by the highway construction. Based on data from undisturbed areas upstream from construction, the normal background load at Trace Fork downstream from construction during the period July 1980 to September 1981 was estimated to be 830 tons; the measured load was 2,385 tons. Runoff from the 0.35 sq mi area disturbed by highway construction transported approximately 1,550 tons of sediment. Suspended-sediment loads from the construction zone were also higher than normal background loads during storms. (USGS)
Low cortical iron and high entorhinal cortex volume promote cognitive functioning in the oldest-old.
van Bergen, Jiri M G; Li, Xu; Quevenco, Frances C; Gietl, Anton F; Treyer, Valerie; Leh, Sandra E; Meyer, Rafael; Buck, Alfred; Kaufmann, Philipp A; Nitsch, Roger M; van Zijl, Peter C M; Hock, Christoph; Unschuld, Paul G
2018-04-01
The aging brain is characterized by an increased presence of neurodegenerative and vascular pathologies. However, there is substantial variation regarding the relationship between an individual's pathological burden and resulting cognitive impairment. To identify correlates of preserved cognitive functioning at highest age, the relationship between β-amyloid plaque load, presence of small vessel cerebrovascular disease (SVCD), iron-burden, and brain atrophy was investigated. Eighty cognitively unimpaired participants (44 oldest-old, aged 85-96 years; 36 younger-old, aged 55-80 years) were scanned by integrated positron emission tomography-magnetic resonance imaging for assessing beta regional amyloid plaque load (18F-flutemetamol), white matter hyperintensities as an indicator of SVCD (fluid-attenuated inversion recovery-magnetic resonance imaging), and iron load (quantitative susceptibility mapping). For the oldest-old group, lower cortical volume, increased β-amyloid plaque load, prevalence of SVCD, and lower cognitive performance in the normal range were found. However, compared to normal-old, cortical iron burden was lower in the oldest-old. Moreover, only in the oldest-old, entorhinal cortex volume positively correlated with β-amyloid plaque load. Our data thus indicate that the co-occurrence of aging-associated neuropathologies with reduced quantitative susceptibility mapping measures of cortical iron load constitutes a lower vulnerability to cognitive loss. Copyright © 2017 Elsevier Inc. All rights reserved.
14 CFR 25.527 - Hull and main float load factors.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Hull and main float load factors. 25.527... AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Structure Water Loads § 25.527 Hull and main... 1=empirical hull station weighing factor, in accordance with figure 2 of appendix B. (7) r x=ratio...
Testing Measurement Invariance Using MIMIC: Likelihood Ratio Test with a Critical Value Adjustment
ERIC Educational Resources Information Center
Kim, Eun Sook; Yoon, Myeongsun; Lee, Taehun
2012-01-01
Multiple-indicators multiple-causes (MIMIC) modeling is often used to test a latent group mean difference while assuming the equivalence of factor loadings and intercepts over groups. However, this study demonstrated that MIMIC was insensitive to the presence of factor loading noninvariance, which implies that factor loading invariance should be…
Zhu, Chun-Hui; Zhao, Man-Zhi; Chen, Guang; Qi, Jun-Ying; Song, Jian-Xin; Ning, Qin; Xu, Dong
2017-02-01
Hepatitis associated anti-tuberculous treatment (HATT) has been a main obstacle in managing patients co-infected with Mycobacterium tuberculosis and hepatitis B virus (HBV). Therefore, we evaluated the factors related to the severity of adverse effects during HATT, especially those associated with liver failure. A retrospective study was carried out at Tongji Hospital from 2007 to 2012. Increases in serum transaminase levels of >3, 5, and 10 times the upper limit of normal (ULN) were used to define liver damage as mild, moderate, and severe, respectively. Patients with elevated total bilirubin (TBil) levels that were more than 10 times the ULN (>171 μmol/L) with or without decreased (<40%) prothrombin activity (PTA) were diagnosed with liver failure. A cohort of 87 patients was analyzed. The incidence of liver damage and liver failure was 59.8% (n=52) and 25.3% (n=22), respectively. The following variables were correlated with the severity of hepatotoxicity: albumin (ALB) levels, PTA, platelet counts (PLT), and the use of antiretroviral therapies (P<0.05). Hypo-proteinemia and antiretroviral therapy were significantly associated with liver failure, and high viral loads were a significant risk factor with an odds ratio (OR) of 2.066. Judicious follow-up of clinical conditions, liver function tests, and coagulation function, especially in patients with high HBV loads and hypoalbuminemia is recommended. It may be advisable to reconsider the use of antiviral drugs failure during the course of anti-tuberculous treatment of HBV infection patients to avoid the occurrence of furious liver failure.
An Efficient Framework Model for Optimizing Routing Performance in VANETs.
Al-Kharasani, Nori M; Zulkarnain, Zuriati Ahmad; Subramaniam, Shamala; Hanapi, Zurina Mohd
2018-02-15
Routing in Vehicular Ad hoc Networks (VANET) is a bit complicated because of the nature of the high dynamic mobility. The efficiency of routing protocol is influenced by a number of factors such as network density, bandwidth constraints, traffic load, and mobility patterns resulting in frequency changes in network topology. Therefore, Quality of Service (QoS) is strongly needed to enhance the capability of the routing protocol and improve the overall network performance. In this paper, we introduce a statistical framework model to address the problem of optimizing routing configuration parameters in Vehicle-to-Vehicle (V2V) communication. Our framework solution is based on the utilization of the network resources to further reflect the current state of the network and to balance the trade-off between frequent changes in network topology and the QoS requirements. It consists of three stages: simulation network stage used to execute different urban scenarios, the function stage used as a competitive approach to aggregate the weighted cost of the factors in a single value, and optimization stage used to evaluate the communication cost and to obtain the optimal configuration based on the competitive cost. The simulation results show significant performance improvement in terms of the Packet Delivery Ratio (PDR), Normalized Routing Load (NRL), Packet loss (PL), and End-to-End Delay (E2ED).
Rise time analysis of pulsed klystron-modulator for efficiency improvement of linear colliders
NASA Astrophysics Data System (ADS)
Oh, J. S.; Cho, M. H.; Namkung, W.; Chung, K. H.; Shintake, T.; Matsumoto, H.
2000-04-01
In linear accelerators, the periods during the rise and fall of a klystron-modulator pulse cannot be used to generate RF power. Thus, these periods need to be minimized to get high efficiency, especially in large-scale machines. In this paper, we present a simplified and generalized voltage rise time function of a pulsed modulator with a high-power klystron load using the equivalent circuit analysis method. The optimum pulse waveform is generated when this pulsed power system is tuned with a damping factor of ˜0.85. The normalized rise time chart presented in this paper allows one to predict the rise time and pulse shape of the pulsed power system in general. The results can be summarized as follows: The large distributed capacitance in the pulse tank and operating parameters, Vs× Tp , where Vs is load voltage and Tp is the pulse width, are the main factors determining the pulse rise time in the high-power RF system. With an RF pulse compression scheme, up to ±3% ripple of the modulator voltage is allowed without serious loss of compressor efficiency, which allows the modulator efficiency to be improved as well. The wiring inductance should be minimized to get the fastest rise time.
14 CFR 27.683 - Operation tests.
Code of Federal Regulations, 2013 CFR
2013-01-01
... STANDARDS: NORMAL CATEGORY ROTORCRAFT Design and Construction Control Systems § 27.683 Operation tests. It must be shown by operation tests that, when the controls are operated from the pilot compartment with the control system loaded to correspond with loads specified for the system, the system is free from...
Performance of HESCO Bastion Units Under Combined Normal and Cyclic Lateral Loading
that use indigenous materials in place of commercial materials manufactured far away. An established construction system called the HESCO bastion...currently used in theater for force protection, derives its mass and load resistance from indigenous soils placed in manufactured steel and geotextile
14 CFR 23.341 - Gust loads factors.
Code of Federal Regulations, 2014 CFR
2014-01-01
... loads factors. (a) Each airplane must be designed to withstand loads on each lifting surface resulting...=airplane mass ratio; U de=Derived gust velocities referred to in § 23.333(c) (f.p.s.); ρ=Density of air... C NA per radian if the gust loads are applied to the wings and horizontal tail surfaces...
14 CFR 23.341 - Gust loads factors.
Code of Federal Regulations, 2012 CFR
2012-01-01
... loads factors. (a) Each airplane must be designed to withstand loads on each lifting surface resulting...=airplane mass ratio; U de=Derived gust velocities referred to in § 23.333(c) (f.p.s.); ρ=Density of air... C NA per radian if the gust loads are applied to the wings and horizontal tail surfaces...
14 CFR 23.341 - Gust loads factors.
Code of Federal Regulations, 2013 CFR
2013-01-01
... loads factors. (a) Each airplane must be designed to withstand loads on each lifting surface resulting...=airplane mass ratio; U de=Derived gust velocities referred to in § 23.333(c) (f.p.s.); ρ=Density of air... C NA per radian if the gust loads are applied to the wings and horizontal tail surfaces...
14 CFR 23.341 - Gust loads factors.
Code of Federal Regulations, 2011 CFR
2011-01-01
... loads factors. (a) Each airplane must be designed to withstand loads on each lifting surface resulting...=airplane mass ratio; U de=Derived gust velocities referred to in § 23.333(c) (f.p.s.); ρ=Density of air... C NA per radian if the gust loads are applied to the wings and horizontal tail surfaces...
Meyer, N K; Ristovski, Z D
2007-11-01
The volatile and hygroscopic properties of diesel nanoparticles were simultaneously determined under a range of engine loads using the volatilization and humidification tandem differential mobility analyzer (VH-TDMA). Additionally, the VH-TDMA was used to measure changes in the hygroscopic behavior of the heterogeneously nucleated diesel nanoparticles as one or more semivolatile species were removed via thermal evaporation or decomposition. Particles produced at high loads exhibited high, dual-step volatility, while those particles produced at low loads were less volatile and exhibited continuous volatilization curves. The hygroscopic growth factor of the particles was shown to be load dependent with high-load particles exhibiting growth factors similar to that of ammonium sulfate. At 85% relative humidity, particles produced at moderate loads exhibited growth factors of approximately 1.1 while low-load particles were shown to be hydrophobic. Growth factors and volatilization temperatures measured for high-load particles clearly indicate that ternary nucleation is involved in particle formation.
Petzold, A; Weingartner, E; Hasselbach, J; Lauer, P; Kurok, C; Fleischer, F
2010-05-15
Particulate matter (PM) emissions from one serial 4-stroke medium-speed marine diesel engine were measured for load conditions from 10% to 110% in test rig studies using heavy fuel oil (HFO). Testing the engine across its entire load range permitted the scaling of exhaust PM properties with load. Emission factors for particle number, particle mass, and chemical compounds were determined. The potential of particles to form cloud droplets (cloud condensation nuclei, CCN) was calculated from chemical composition and particle size. Number emission factors are (3.43 +/- 1.26) x 10(16) (kg fuel)(-1) at 85-110% load and (1.06 +/- 0.10) x 10(16) (kg fuel)(-1) at 10% load. CCN emission factors of 1-6 x 10(14) (kg fuel)(-1) are at the lower bound of data reported in the literature. From combined thermal and optical methods, black carbon (BC) emission factors of 40-60 mg/(kg fuel) were determined for 85-100% load and 370 mg/(kg fuel) for 10% load. The engine load dependence of the conversion efficiency for fuel sulfur into sulfate of (1.08 +/- 0.15)% at engine idle to (3.85 +/- 0.41)% at cruise may serve as input to global emission calculations for various load conditions.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jones, David Robert; Fensin, Saryu Jindal; Dippo, Olivia
Here, we present a study on the spall strength of additive manufactured (AM) Ti-6Al-4V. Samples were obtained from two pieces of selective laser melted (SLM, a powder bed fusion technique) Ti-6Al-4V such that the response to dynamic tensile loading could be investigated as a function of the orientation between the build layers and the loading direction. A sample of wrought bar-stock Ti-6Al-4V was also tested to act as a baseline representing the traditionally manufactured material response. A single-stage light gas-gun was used to launch a thin flyer plate into the samples, generating a region of intense tensile stress on amore » plane normal to the impact direction. The rear free surface velocity time history of each sample was recorded with laser-based velocimetry to allow the spall strength to be calculated. The samples were also soft recovered to enable post-mortem characterization of the spall damage evolution. Results showed that when the tensile load was applied normal to the interfaces between the build layers caused by the SLM fabrication process the spall strength was drastically reduced, dropping to 60% of that of the wrought material. However, when loaded parallel to the AM build layer interfaces the spall strength was found to remain at 95% of the wrought control, suggesting that when loading normal to the AM layer interfaces, void nucleation is facilitated more readily due to weaknesses along these boundaries. Quasi-static testing of the same sample orientations revealed a much lower degree of anisotropy, demonstrating the importance of rate-dependent studies for damage evolution in AM materials.« less
Influence of two-dimensional hygrothermal gradients on interlaminar stresses near free edges
NASA Technical Reports Server (NTRS)
Farley, G. L.; Herakovich, C. T.
1977-01-01
Interlaminar stresses are determined for mechanical loading, uniform hygrothermal loading, and gradient moisture loading through implementation of a finite element computer code. Nonuniform two-dimensional hygroscopic gradients are obtained from a finite difference solution of the diffusion equation. It is shown that hygroscopic induced stresses can be larger than those resulting from mechanical and thermal loading, and that the distribution of the interlaminar normal stress may be changed significantly in the presence of a two-dimensional moisture gradient in the boundary layer of a composite laminate.
14 CFR 27.473 - Ground loading conditions and assumptions.
Code of Federal Regulations, 2013 CFR
2013-01-01
... through the center of gravity throughout the landing impact. This lift may not exceed two-thirds of the... rotorcraft must be designed for a limit load factor of not less than the limit inertia load factor...
14 CFR 27.473 - Ground loading conditions and assumptions.
Code of Federal Regulations, 2012 CFR
2012-01-01
... through the center of gravity throughout the landing impact. This lift may not exceed two-thirds of the... rotorcraft must be designed for a limit load factor of not less than the limit inertia load factor...
14 CFR 27.473 - Ground loading conditions and assumptions.
Code of Federal Regulations, 2014 CFR
2014-01-01
... through the center of gravity throughout the landing impact. This lift may not exceed two-thirds of the... rotorcraft must be designed for a limit load factor of not less than the limit inertia load factor...
Improved LRFD/LRFR specifications for permit and fatigue load truck.
DOT National Transportation Integrated Search
2011-01-01
Bridge design and evaluation are moving toward the American Association of State Highway and Transportation : Officials (AASHTO) load and resistance factor design/load and resistance factor rating (LRFD/LRFR) : specifications using calibrated truck l...
Healthy eating opinion survey for individuals at risk for cardiovascular disease.
Mark, Amy E; Riley, Dana L; McDonnell, Lisa A; Pipe, Andrew L; Reid, Robert D
2014-08-01
To develop and evaluate the validity and reliability of a questionnaire to measure intentions and beliefs about healthy eating in individuals at risk for coronary heart disease. The Healthy Eating Opinion Survey was developed using the theory of planned behavior. An open-ended elicitation questionnaire was administered to 21 participants, and a 46-item questionnaire was developed for further testing. Test-retest reliability of each question on the survey was assessed by calculating the correlation coefficients between the responses over a 2- week period in 17 participants. Internal consistency was assessed using Cronbach's alpha, and factor analysis was used to assess the construct validity of the questionnaire in a sample of 388 participants. The responses to the elicitation questions were used to develop behavioral beliefs, normative beliefs, and control beliefs questions for the final questionnaire. Test-retest reliability ranged from 0.22-0.90, with the majority (89%) of correlations being moderate to strong. Internal consistency was good, with Cronbach's alpha ranging from 0.74-0.92. All intentions questions loaded onto a single factor; attitude questions loaded onto two factors; subjective norm questions loaded onto two factors; perceived behavioral control questions loaded onto one factor; behavioral beliefs questions loaded onto one factor; normative beliefs questions loaded onto one factor; and control beliefs questions loaded onto one factor. The questionnaire was found to be a reliable, valid questionnaire to assess beliefs and intentions toward eating a healthy diet in individuals at risk for coronary heart disease.
NASA Astrophysics Data System (ADS)
Turkova, Vera; Stepanova, Larisa
2018-03-01
For elastistoplastic structure elements under cyclic loading three types of asymptotic behavior are well known: shakedown, cyclic plasticity or ratcheting. In structure elements operating in real conditions ratcheting must always be excluded since it caused the incremental fracture of structure by means of the accumulation of plastic strains. In the present study results of finite-element (FEM) calculations of the asymptotical behavior of an elastoplastic plate with the central circular and elliptic holes under the biaxial cyclic loading for three different materials are presented. Incremental cyclic loading of the sample with stress concentrator (the central hole) is performed in the multifunctional finite-element package SIMULIA Abaqus. The ranges of loads found for shakedown, cyclic plasticity and ratcheting are presented. The results obtained are generalized and analyzed. Convenient normalization is suggested. The chosen normalization allows us to present all computed results, corresponding to separate materials, within one common curve with minimum scattering of the points. Convenience of the generalized diagram consists in a possibility to find an asymptotical behavior of an inelastic structure for materials for which computer calculations were not made.
Vermeij, Anouk; Kessels, Roy P C; Heskamp, Linda; Simons, Esther M F; Dautzenberg, Paul L J; Claassen, Jurgen A H R
2017-02-01
Cognitive training has been shown to result in improved behavioral performance in normal aging and mild cognitive impairment (MCI), yet little is known about the neural correlates of cognitive plasticity, or about individual differences in responsiveness to cognitive training. In this study, 21 healthy older adults and 14 patients with MCI received five weeks of adaptive computerized working-memory (WM) training. Before and after training, functional Near-Infrared Spectroscopy (fNIRS) was used to assess the hemodynamic response in left and right prefrontal cortex during performance of a verbal n-back task with varying levels of WM load. After training, healthy older adults demonstrated decreased prefrontal activation at high WM load, which may indicate increased processing efficiency. Although MCI patients showed improved behavioral performance at low WM load after training, no evidence was found for training-related changes in prefrontal activation. Whole-group analyses showed that a relatively strong hemodynamic response at low WM load was related to worse behavioral performance, while a relatively strong hemodynamic response at high WM load was related to higher training gain. Therefore, a 'youth-like' prefrontal activation pattern at older age may be associated with better behavioral outcome and cognitive plasticity.
Steiner, Malte; Claes, Lutz; Ignatius, Anita; Simon, Ulrich; Wehner, Tim
2014-07-01
The outcome of secondary fracture healing processes is strongly influenced by interfragmentary motion. Shear movement is assumed to be more disadvantageous than axial movement, however, experimental results are contradictory. Numerical fracture healing models allow simulation of the fracture healing process with variation of single input parameters and under comparable, normalized mechanical conditions. Thus, a comparison of the influence of different loading directions on the healing process is possible. In this study we simulated fracture healing under several axial compressive, and translational and torsional shear movement scenarios, and compared their respective healing times. Therefore, we used a calibrated numerical model for fracture healing in sheep. Numerous variations of movement amplitudes and musculoskeletal loads were simulated for the three loading directions. Our results show that isolated axial compression was more beneficial for the fracture healing success than both isolated shearing conditions for load and displacement magnitudes which were identical as well as physiological different, and even for strain-based normalized comparable conditions. Additionally, torsional shear movements had less impeding effects than translational shear movements. Therefore, our findings suggest that osteosynthesis implants can be optimized, in particular, to limit translational interfragmentary shear under musculoskeletal loading. © 2014 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.
Ormel, J; Oldehinkel, A J; Ferdinand, R F; Hartman, C A; De Winter, A F; Veenstra, R; Vollebergh, W; Minderaa, R B; Buitelaar, J K; Verhulst, F C
2005-12-01
We investigated the links between familial loading, preadolescent temperament, and internalizing and externalizing problems in adolescence, hereby distinguishing effects on maladjustment in general versus dimension-specific effects on either internalizing or externalizing problems. In a population-based sample of 2230 preadolescents (10-11 years) familial loading (parental lifetime psychopathology) and offspring temperament were assessed at baseline by parent report, and offspring psychopathology at 2.5-years follow-up by self-report, teacher report and parent report. We used purified measures of temperament and psychopathology and partialled out shared variance between internalizing and externalizing problems. Familial loading of internalizing psychopathology predicted offspring internalizing but not externalizing problems, whereas familial loading of externalizing psychopathology predicted offspring externalizing but not internalizing problems. Both familial loadings were associated with Frustration, low Effortful Control, and Fear. Frustration acted as a general risk factor predicting severity of maladjustment; low Effortful Control and Fear acted as dimension-specific risk factors that predicted a particular type of psychopathology; whereas Shyness, High-Intensity Pleasure, and Affiliation acted as direction markers that steered the conditional probability of internalizing versus externalizing problems, in the event of maladjustment. Temperament traits mediated one-third of the association between familial loading and psychopathology. Findings were robust across different composite measures of psychopathology, and applied to girls as well as boys. With regard to familial loading and temperament, it is important to distinguish general risk factors (Frustration) from dimension-specific risk factors (familial loadings, Effortful Control, Fear), and direction markers that act as pathoplastic factors (Shyness, High-Intensity Pleasure, Affiliation) from both types of risk factors. About one-third of familial loading effects on psychopathology in early adolescence are mediated by temperament.
Distribution of contact loads over the flank-land of the cutter with a rounded cutting edge
NASA Astrophysics Data System (ADS)
Kozlov, V.; Gerasimov, A.; Kim, A.
2016-04-01
In this paper, contact conditions between a tool and a workpiece material for wear-simulating turning by a cutter with a sharp-cornered edge and with a rounded cutting edge are analysed. The results of the experimental study of specific contact load distribution over the artificial flank wear-land of the cutter in free orthogonal turning of the disk from titanium alloy (Ti6Al2Mo2Cr), ductile (63Cu) and brittle (57Cu1Al3Mn) brasses are described. Investigations were carried out by the method of ‘split cutter’ and by the method of the artificial flank-land of variable width. The experiments with a variable feed rate and a cutting speed show that in titanium alloy machining with a sharp-cornered cutting edge the highest normal contact load (σh max = 3400…2200 MPa) is observed immediately at the cutting edge, and the curve has a horizontal region with the length of 0.2… 0.6 mm. At a distance from the cutting edge, the value of specific normal contact load is dramatically reduced to 1100…500 MPa. The character of normal contact load for a rounded cutting edge is different -it is uniform, and its value is approximately 2 times smaller compared to machining with a sharp-cornered cutting edge. In author’s opinion it is connected with generation of a seizure zone in a chip formation region and explains the capacity of highly worn-out cutting tools for titanium alloys machining. The paper analyses the distribution of tangential contact loads over the flank land, which pattern differs considerably for machining with a sharp-cornered edge and with a rounded cutting edge. Abbreviation and symbols: m/s - meter per second (cutting speed v); mm/r - millimeter per revolution (feed rate f); MPa - mega Pascal (specific contact load as a stress σ or τ) hf - the width of the flank wear land (chamfer) of the cutting tool, flank wear land can be natural or artificial like the one in this paper [mm]; xh - distance from the cutting edge on the surface of the flank-land [mm]; σh - normal specific contact load on the flank land [MPa]; τh - tangential (shear) specific contact load on the flank land [MPa]; HSS - high speed steel (material of cutting tool); Py - radial component of cutting force [N]; Py r - radial component of cutting force on the rake face [N]; Pz - tangential component of cutting force [N]; γ - rake angle of the cutting tool [°] α - clearance angle of the sharp cutting tool [°] αh - clearance angle of the flank wear land [°] ρ - rounding off radius of the cutting edge [mm]; b - width of the machined disk [mm].
14 CFR 29.473 - Ground loading conditions and assumptions.
Code of Federal Regulations, 2014 CFR
2014-01-01
... through the center of gravity throughout the landing impact. This lift may not exceed two-thirds of the... rotorcraft must be designed for a limit load factor of not less than the limit inertia load factor... factor of safety prescribed in § 29.303 need not be used. [Amdt. 29-3, 33 FR 966, Jan. 26, 1968] ...
14 CFR 29.473 - Ground loading conditions and assumptions.
Code of Federal Regulations, 2012 CFR
2012-01-01
... through the center of gravity throughout the landing impact. This lift may not exceed two-thirds of the... rotorcraft must be designed for a limit load factor of not less than the limit inertia load factor... factor of safety prescribed in § 29.303 need not be used. [Amdt. 29-3, 33 FR 966, Jan. 26, 1968] ...
14 CFR 29.473 - Ground loading conditions and assumptions.
Code of Federal Regulations, 2013 CFR
2013-01-01
... through the center of gravity throughout the landing impact. This lift may not exceed two-thirds of the... rotorcraft must be designed for a limit load factor of not less than the limit inertia load factor... factor of safety prescribed in § 29.303 need not be used. [Amdt. 29-3, 33 FR 966, Jan. 26, 1968] ...
14 CFR 23.725 - Limit drop tests.
Code of Federal Regulations, 2011 CFR
2011-01-01
... assumed wing lift to the airplane weight, but not more than 0.667. (c) The limit inertia load factor must... test. (e) The limit inertia load factor must be determined from the drop test in paragraph (b) of this... paragraph (e) may not be more than the limit inertia load factor used in the landing conditions in § 23.473...
14 CFR 23.725 - Limit drop tests.
Code of Federal Regulations, 2013 CFR
2013-01-01
... assumed wing lift to the airplane weight, but not more than 0.667. (c) The limit inertia load factor must... test. (e) The limit inertia load factor must be determined from the drop test in paragraph (b) of this... paragraph (e) may not be more than the limit inertia load factor used in the landing conditions in § 23.473...
14 CFR 23.725 - Limit drop tests.
Code of Federal Regulations, 2012 CFR
2012-01-01
... assumed wing lift to the airplane weight, but not more than 0.667. (c) The limit inertia load factor must... test. (e) The limit inertia load factor must be determined from the drop test in paragraph (b) of this... paragraph (e) may not be more than the limit inertia load factor used in the landing conditions in § 23.473...
14 CFR 23.725 - Limit drop tests.
Code of Federal Regulations, 2014 CFR
2014-01-01
... assumed wing lift to the airplane weight, but not more than 0.667. (c) The limit inertia load factor must... test. (e) The limit inertia load factor must be determined from the drop test in paragraph (b) of this... paragraph (e) may not be more than the limit inertia load factor used in the landing conditions in § 23.473...
Camozzi, V; Frigo, A C; Zaninotto, M; Sanguin, F; Plebani, M; Boscaro, M; Schiavon, L; Luisetto, G
2016-08-01
After a single cholecalciferol load, peak serum 25-hydroxycholecalciferol (25OHD) is lower in individuals with a higher body mass index (BMI), probably due to it being distributed in a greater volume. Its subsequent disappearance from the serum is slower the higher the individual's BMI, probably due to the combination of a larger body volume and a slower release into the circulation of vitamin D stored in adipose tissue. The aim of the study is to examine 25-hydroxycholecalciferol (25OHD) response to a single oral load of cholecalciferol in the normal weight, overweight, and obese. We considered 55 healthy women aged from 25 to 67 years (mean ± SD, 50.8 ± 9.5) with a BMI ranging from 18.7 to 42 kg/m(2) (mean ± SD, 27.1 ± 6.0). The sample was divided into three groups by BMI: 20 were normal weight (BMI ≤ 25 kg/m(2)), 21 overweight (25.1 ≤ BMI ≤ 29.9 kg/ m(2)), and 14 obese (BMI ≥ 30 kg/m(2)). Each subject was given 300,000 IU of cholecalciferol orally during lunch. A fasting blood test was obtained before cholecalciferol loading and then 7, 30, and 90 days afterwards to measure serum 25OHD, 1,25 dihydroxyvitamin D [1,25 (OH)2D], parathyroid hormone (PTH), calcium (Ca), and phosphorus (P). Participants' absolute fat mass was measured using dual energy X-ray absorptiometry (DEXA). The fat mass of the normal weight subjects was significantly lower than that of the overweight, which in turn was lower than that of the obese participants. Serum 25OHD levels increased significantly in all groups, peaking 1 week after the cholecalciferol load. Peak serum 25OHD levels were lower the higher the individuals' BMI. After peaking, the 25OHD levels gradually decreased, following a significantly different trend in the three groups. The slope was similar for the overweight and obese, declining significantly more slowly than in the normal weight group. In the sample as a whole, there was a weakly significant negative correlation between fat mass and baseline 25OHD level, while this correlation became strongly significant at all time points after cholecalciferol loading. The lower peak 25OHD levels seen in the obese and overweight is probably due to the cholecalciferol load being distributed in a larger body volume. The longer persistence of 25OHD in their serum could be due to both their larger body volume and a slower release into the circulation of the vitamin D stored in their adipose tissue.
Effects of shear coupling on shear properties of wood
Jen Y. Liu
2000-01-01
Under pure shear loading, an off-axis element of orthotropic material such as pure wood undergoes both shear and normal deformations. The ratio of the shear strain to a normal strain is defined as the shear coupling coefficient associated with the direction of the normal strain. The effects of shear coupling on shear properties of wood as predicted by the orthotropic...
Mijajlović, Milija D; Aleksić, Vuk M; Šternić, Nadežda M; Mirković, Mihailo M; Bornstein, Natan M
2017-01-01
Stroke is one of the leading causes of death and probably the greatest cause of adult disability worldwide. Diabetes mellitus (DM) is a state of accelerated aging of blood vessels. Patients with diabetes have increased risk of stroke. Hyperglycemia represents a risk factor for poor outcome following stroke, and probably is just a marker of poor outcome rather than a cause. Lowering of blood glucose levels has not been shown to improve prognosis. Also, prevention of stroke risk among patients with DM is not improved with therapy for reduction of glucose levels. On the other hand, prediabetes, a metabolic state between normal glucose metabolism and diabetes, is a risk factor for the development of DM type 2 and subsequently for stroke. Several methods are known to identify prediabetes patients, including fasting plasma glucose levels, 2-hour post load glucose levels, and glycosylated hemoglobin levels. In this text, we tried to summarize known data about diagnosis, epidemiology, risk factors, pathophysiology, and prevention of prediabetes in relation to DM and stroke. PMID:28203079
Race, Amos; Miller, Mark A; Mann, Kenneth A
2008-10-20
Pre-clinical screening of cemented implant systems could be improved by modeling the longer-term response of the implant/cement/bone construct to cyclic loading. We formulated bone cement with degraded fatigue fracture properties (Sub-cement) such that long-term fatigue could be simulated in short-term cadaver tests. Sub-cement was made by adding a chain-transfer agent to standard polymethylmethacrylate (PMMA) cement. This reduced the molecular weight of the inter-bead matrix without changing reaction-rate or handling characteristics. Static mechanical properties were approximately equivalent to normal cement. Over a physiologically reasonable range of stress-intensity factor, fatigue crack propagation rates for Sub-cement were higher by a factor of 25+/-19. When tested in a simplified 2 1/2-D physical model of a stem-cement-bone system, crack growth from the stem was accelerated by a factor of 100. Sub-cement accelerated both crack initiation and growth rate. Sub-cement is now being evaluated in full stem/cement/femur models.
Periodically Relieving Ischial Sitting Load to Decrease the Risk of Pressure Ulcers
Makhsous, Mohsen; Rowles, Diane M.; Rymer, William Z.; Bankard, James; Nam, Ellis K.; Chen, David; Lin, Fang
2010-01-01
Objective To investigate the relieving effect on interface pressure of an alternate sitting protocol involving a sitting posture that reduces ischial support. Design Repeated measures in 2 protocols on 3 groups of subjects. Setting Laboratory. Participants Twenty able-bodied persons, 20 persons with paraplegia, and 20 persons with tetraplegia. Interventions Two 1-hour protocols were used: alternate and normal plus pushup. In the alternate protocol, sitting posture was alternated every 10 minutes between normal (sitting upright with ischial support) and with partially removed ischial support (WO-BPS) postures; in the normal plus pushup protocol, sitting was in normal posture with pushups (lifting the subject off the seat) performed every 20 minutes. Main Outcome Measure Interface pressure on seat and backrest. Results In WO-BPS posture, the concentrated interface pressure observed around the ischia in normal posture was significantly repositioned to the thighs. By cyclically repositioning the interface pressure, the alternate protocol was superior to the normal plus pushup protocol in terms of a significantly lower average interface pressure over the buttocks. Conclusions A sitting protocol periodically reducing the ischial support helps lower the sitting load on the buttocks, especially the area close to ischial tuberosities. PMID:17601466
ERIC Educational Resources Information Center
OOSTING, KENNETH W.
AT ALPENA COMMUNITY COLLEGE, A NORMAL TEACHING LOAD FOR ANY FACULTY MEMBER IS 14-16 SEMESTER HOURS, WITH 75-125 STUDENTS AND 2-3 PREPARATIONS. VARIATIONS FROM THE SCHEDULE ARE IN ACCORDANCE WITH SPECIFIC FORMULAS RELATING TO TOTAL MEMBERS OF STUDENTS, NUMBERS OF PREPARATIONS, ASSIGNMENT TO ENGLISH COMPOSITION CLASSES, NEW COURSES, AND CLASSES…
30 CFR 70.207 - Bimonthly sampling; mechanized mining units.
Code of Federal Regulations, 2012 CFR
2012-07-01
... sampling device as follows: (1) Conventional section using cutting machine. On the cutting machine operator or on the cutting machine within 36 inches inby the normal working position; (2) Conventional section shooting off the solid. On the loading machine operator or on the loading machine within 36 inches inby the...
30 CFR 70.207 - Bimonthly sampling; mechanized mining units.
Code of Federal Regulations, 2014 CFR
2014-07-01
... sampling device as follows: (1) Conventional section using cutting machine. On the cutting machine operator or on the cutting machine within 36 inches inby the normal working position; (2) Conventional section shooting off the solid. On the loading machine operator or on the loading machine within 36 inches inby the...
30 CFR 70.207 - Bimonthly sampling; mechanized mining units.
Code of Federal Regulations, 2013 CFR
2013-07-01
... sampling device as follows: (1) Conventional section using cutting machine. On the cutting machine operator or on the cutting machine within 36 inches inby the normal working position; (2) Conventional section shooting off the solid. On the loading machine operator or on the loading machine within 36 inches inby the...
47 CFR 80.915 - Main power supply.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 47 Telecommunication 5 2010-10-01 2010-10-01 false Main power supply. 80.915 Section 80.915... supply. (a) There must be readily available for use under normal load conditions a main power supply... required receiver. Under this load condition the potential of the main power supply at the power input...
47 CFR 80.915 - Main power supply.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 47 Telecommunication 5 2011-10-01 2011-10-01 false Main power supply. 80.915 Section 80.915... supply. (a) There must be readily available for use under normal load conditions a main power supply... required receiver. Under this load condition the potential of the main power supply at the power input...
One approach to developing criteria for nitrogen (N) in coastal waters has been to determine quantitative relationships between N loading and ecological effects (e.g., hypoxia) in coastal estuaries. Although this approach has met with some success, data obtained from field sites ...
Hydromechanical effects of continental glaciation on groundwater systems
Neuzil, C.E.
2012-01-01
Hydromechanical effects of continental ice sheets may involve considerably more than the widely recognized direct compression of overridden terrains by ice load. Lithospheric flexure, which lags ice advance and retreat, appears capable of causing comparable or greater stress changes. Together, direct and flexural loading may increase fluid pressures by tens of MPa in geologic units unable to drain. If so, fluid pressures in low-permeability formations subject to glaciation may have increased and decreased repeatedly during cycles of Pleistocene glaciation and can again in the future. Being asynchronous and normally oriented, direct and flexural loading presumably cause normal and shear stresses to evolve in a complex fashion through much or all of a glacial cycle. Simulations of fractured rock predict permeability might vary by two to three orders of magnitude under similar stress changes as fractures at different orientations are subjected to changing normal and shear stresses and some become critically stressed. Uncertainties surrounding these processes and their interactions, and the confounding influences of surface hydrologic changes, make it challenging to delineate their effects on groundwater flow and pressure regimes with any specificity. To date, evidence for hydromechanical changes caused by the last glaciation is sparse and inconclusive, comprising a few pressure anomalies attributed to the removal of direct ice load. This may change as more data are gathered, and understanding of relevant processes is refined.
Code of Federal Regulations, 2010 CFR
2010-01-01
... load would significantly change the distribution of external or internal loads, this redistribution...) and ultimate loads (limit loads multiplied by prescribed factors of safety). Unless otherwise provided...
Wind loads on flat plate photovoltaic array fields (nonsteady winds)
NASA Technical Reports Server (NTRS)
Miller, R. D.; Zimmerman, D. K.
1981-01-01
Techniques to predict the dynamic response and the structural dynamic loads of flat plate photovoltaic arrays due to wind turbulence were analyzed. Guidelines for use in predicting the turbulent portion of the wind loading on future similar arrays are presented. The dynamic response and the loads dynamic magnification factor of the two array configurations are similar. The magnification factors at a mid chord and outer chord location on the array illustrated and at four points on the chord are shown. The wind tunnel test experimental rms pressure coefficient on which magnification factors are based is shown. It is found that the largest response and dynamic magnification factor occur at a mid chord location on an array and near the trailing edge. A technique employing these magnification factors and the wind tunnel test rms fluctuating pressure coefficients to calculate design pressure loads due to wind turbulence is presented.
Effect of stress perturbation on frictional instability: an experimental study
NASA Astrophysics Data System (ADS)
Yuanmin, H.; Shengli, M.
2017-12-01
We have performed a series of frictional experiments with direct shear configuration of three granite blocks by using a servo-controlled biaxial loading machine. In the experiments, a small- amplitude sine wave is modulated to shear and normal loading in order to study the effects of stress perturbation on stick-slip instability. The main results are as follows. Under the constant average normal stress and the constant loading point velocity in shear direction, the sample shows regular stick-slip behavior. After the stress perturbation is modulated, the correlation between the timing of stick-slip events and the perturbation increases with increasing the perturbation amplitude, and stress drop and interval time of stick-slip events tend to be discrete. This results imply that the change in Coulomb stress caused by stress perturbation may obviously change not only the occurrence time of earthquakes but also the earthquake magnitude. Both shear and normal stress perturbation can affect the stick-slip behavior, shear stress perturbation can only change the driving stress along fault, while the normal stress perturbation can change the contact state of asperities on the fault, so it's effect is more obviously. The stress perturbation can obviously affect acoustic emission (AE) activity during fault friction, which can trigger some AE events so that AE activity before stick-slip becomes stronger and occurs earlier. The perturbation in shear stress is more evident than that in normal stress in affecting AE activity, so we should not only pay attention to the magnitude of Coulomb stress changes caused by the perturbation, but also try to distinguish the stress changes are the shear stress changes or the normal stress changes, when study the effect of stress perturbation on fault friction.
Sanyal, Arnav; Keaveny, Tony M.
2013-01-01
The biaxial failure behavior of the human trabecular bone, which has potential relevance both for fall and gait loading conditions, is not well understood, particularly for low-density bone, which can display considerable mechanical anisotropy. Addressing this issue, we investigated the biaxial normal strength behavior and the underlying failure mechanisms for human trabecular bone displaying a wide range of bone volume fraction (0.06–0.34) and elastic anisotropy. Micro-computer tomography (CT)-based nonlinear finite element analysis was used to simulate biaxial failure in 15 specimens (5 mm cubes), spanning the complete biaxial normal stress failure space in the axial-transverse plane. The specimens, treated as approximately transversely isotropic, were loaded in the principal material orientation. We found that the biaxial stress yield surface was well characterized by the superposition of two ellipses—one each for yield failure in the longitudinal and transverse loading directions—and the size, shape, and orientation of which depended on bone volume fraction and elastic anisotropy. However, when normalized by the uniaxial tensile and compressive strengths in the longitudinal and transverse directions, all of which depended on bone volume fraction, microarchitecture, and mechanical anisotropy, the resulting normalized biaxial strength behavior was well described by a single pair of (longitudinal and transverse) ellipses, with little interspecimen variation. Taken together, these results indicate that the role of bone volume fraction, microarchitecture, and mechanical anisotropy is mostly accounted for in determining the uniaxial strength behavior and the effect of these parameters on the axial-transverse biaxial normal strength behavior per se is minor. PMID:24121715
NASA Astrophysics Data System (ADS)
Yang, B. D.; Menq, C. H.
1998-11-01
A 3D friction contact model has been developed for the prediction of the resonant response of structures having 3D frictional constraint. In the proposed model, a contact plane is defined and its orientation is assumed invariant. Consequently, the relative motion of the two contacting surfaces can be resolved into two components: the in-plane tangential motion on the contact plane and the normal component perpendicular to the plane. The in-plane tangential relative motion is often two-dimensional, and it can induce stick-slip friction. On the other hand, the normal relative motion can cause variation of the contact normal load and, in extreme circumstances, separation of the two contacting surfaces. In this study, the joined effect of the 2D tangential relative motion and the normal relative motion on the contact kinematics of a friction contact is examined and analytical criteria are developed to determine the transitions among stick, slip, and separation, when experiencing variable normal load. With these transition criteria, the induced friction force on the contact plane and the variable normal load perpendicular to the plane can be predicted for any given cyclic relative motions at the contact interface and hysteresis loops can be produced so as to characterize the equivalent damping and stiffness of the friction contact. These non-linear damping and stiffness along with the harmonic balance method are then used to predict the resonance of a frictionally constrained 3-DOF oscillator. The predicted results are compared with those of the time integration method and the damping effect, the resonant frequency shift, and the jump phenomenon are examined.
Innovation of natural essential oil-loaded Orabase for local treatment of oral candidiasis
Labib, Gihan S; Aldawsari, Hibah
2015-01-01
Purpose Oral candidiasis may be manifested in the oral cavity as either mild or severe oral fungal infection. This infection results from the overgrowth of Candida species normally existing in the oral cavity in minute amounts based on many predisposing factors. Several aspects have spurred the search for new strategies in the treatment of oral candidiasis, among which are the limited numbers of new antifungal drugs developed in recent years. Previous studies have shown that thyme and clove oils have antimycotic activities and have suggested their incorporation into pharmaceutical preparations. This study aimed to investigate the possibility of the incorporation and characterization of essential oils or their extracted active ingredients in Orabase formulations. Methods Orabase loaded with clove oil, thyme oil, eugenol, and thymol were prepared and evaluated for their antifungal activities, pH, viscosity, erosion and water uptake characteristics, mechanical properties, in vitro release behavior, and ex vivo mucoadhesion properties. Results All prepared bases showed considerable antifungal activity and acceptable physical characteristics. The release pattern from loaded bases was considerably slow for all oils and active ingredients. All bases showed appreciable adhesion in the in vitro and ex vivo studies. Conclusion The incorporation of essential oils in Orabase could help in future drug delivery design, with promising outcomes on patients’ well-being. PMID:26170621