Sample records for normal operating position

  1. 49 CFR 218.105 - Additional operational requirements for hand-operated main track switches.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Additional operational requirements for hand... hand-operated main track switches. (a) Each railroad shall adopt and comply with an operating rule... the requirements of this section. (b) Designating switch position. The normal position of a hand...

  2. A shut-off valve for flexible tubing

    NASA Technical Reports Server (NTRS)

    Reyburn, W. W.

    1972-01-01

    Design of light weight valve for flexible tubing is described. Valve is hand operated and provides positive sealing in normally closed position. Diagram is provided to show construction of valve. Principles of operation are explained.

  3. Quantum incompatibility of channels with general outcome operator algebras

    NASA Astrophysics Data System (ADS)

    Kuramochi, Yui

    2018-04-01

    A pair of quantum channels is said to be incompatible if they cannot be realized as marginals of a single channel. This paper addresses the general structure of the incompatibility of completely positive channels with a fixed quantum input space and with general outcome operator algebras. We define a compatibility relation for such channels by identifying the composite outcome space as the maximal (projective) C*-tensor product of outcome algebras. We show theorems that characterize this compatibility relation in terms of the concatenation and conjugation of channels, generalizing the recent result for channels with quantum outcome spaces. These results are applied to the positive operator valued measures (POVMs) by identifying each of them with the corresponding quantum-classical (QC) channel. We also give a characterization of the maximality of a POVM with respect to the post-processing preorder in terms of the conjugate channel of the QC channel. We consider another definition of compatibility of normal channels by identifying the composite outcome space with the normal tensor product of the outcome von Neumann algebras. We prove that for a given normal channel, the class of normally compatible channels is upper bounded by a special class of channels called tensor conjugate channels. We show the inequivalence of the C*- and normal compatibility relations for QC channels, which originates from the possibility and impossibility of copying operations for commutative von Neumann algebras in C*- and normal compatibility relations, respectively.

  4. 49 CFR 236.410 - Locking, hand-operated switch; requirements.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 4 2011-10-01 2011-10-01 false Locking, hand-operated switch; requirements. 236... Traffic Control Systems Standards § 236.410 Locking, hand-operated switch; requirements. (a) Each hand-operated switch in main track shall be locked either electrically or mechanically in normal position...

  5. 49 CFR 236.410 - Locking, hand-operated switch; requirements.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Locking, hand-operated switch; requirements. 236... Traffic Control Systems Standards § 236.410 Locking, hand-operated switch; requirements. (a) Each hand-operated switch in main track shall be locked either electrically or mechanically in normal position...

  6. 49 CFR 236.410 - Locking, hand-operated switch; requirements.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 4 2013-10-01 2013-10-01 false Locking, hand-operated switch; requirements. 236... Traffic Control Systems Standards § 236.410 Locking, hand-operated switch; requirements. (a) Each hand-operated switch in main track shall be locked either electrically or mechanically in normal position...

  7. 49 CFR 236.410 - Locking, hand-operated switch; requirements.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 4 2012-10-01 2012-10-01 false Locking, hand-operated switch; requirements. 236... Traffic Control Systems Standards § 236.410 Locking, hand-operated switch; requirements. (a) Each hand-operated switch in main track shall be locked either electrically or mechanically in normal position...

  8. 49 CFR 236.410 - Locking, hand-operated switch; requirements.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 4 2014-10-01 2014-10-01 false Locking, hand-operated switch; requirements. 236... Traffic Control Systems Standards § 236.410 Locking, hand-operated switch; requirements. (a) Each hand-operated switch in main track shall be locked either electrically or mechanically in normal position...

  9. Worcester 1 Inch Solenoid Actuated Gas Operated SCHe System Valves

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    MISKA, C.R.

    1 inch gas-operated full-port ball valves incorporate a solenoid and limit switches as integral parts of the actuator. These valves are normally open and fail safe to the open position (GOV-1*02 and 1*06 fail closed) to provide a flow path of helium gas to the MCO under helium purge and off-normal conditions when the MCO is isolated.

  10. Worcester 1 Inch Solenoid Actuated Gas Operated SCHe System Valves

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    VAN KATWIJK, C.

    1 inch Gas-operated full-port ball valves incorporate a solenoid and limit switches as integral parts of the actuator. These valves are normally open and fail safe to the open position (GOV-1*02 and 1*06 fall closed) to provide a flow path of helium gas to the MCO under helium purge and off-normal conditions when the MCO is isolated.

  11. Worcester 1 Inch Solenoid Actuated Gas Operated SCHe System Valves

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    VAN KATWIJK, C.

    1 inch Gas-operated full-port ball valves incorporate a solenoid and limit switches as integral parts of the actuator. These valves are normally open and fail safe to the open position (GOV-1*02 and 1*06 fail closed) to provide a flow path of helium gas to the MCO under helium purge and off-normal conditions when the MCO is isolated.

  12. CRP in acute appendicitis--is it a necessary investigation?

    PubMed

    Amalesh, T; Shankar, M; Shankar, R

    2004-01-01

    Appendectomy is one of the commonest procedures in surgery. In spite of various investigations used to improve the accuracy of diagnosis, the rate of normal appendices removed is still about 15-30%. Many studies have investigated the role of C-reactive protein (CRP) in acute appendicitis, but with conflicting results. In a prospective, double blind study, blood for the measurement of serum C-reactive protein was collected pre-operatively from 192 children before going to the operating theatre for appendectomy. The histopathology was grouped into positive (acute appendicitis) and negative (normal appendix) and this was correlated with CRP values. CRP was normal in 14 out of 33 negative explorations (normal appendix on histopathology). The specificity and sensitivity of serum CRP was 42% and 91% respectively. The predictive value of a positive (raised CRP) and negative (normal CRP) test is 88% and 48% respectively. We conclude that neither raised nor normal CRP value is helpful in the diagnosis of acute appendicitis. CRP is not a good tool for helping the surgeon make the diagnosis of appendicitis and it should not be measured in suspected appendicitis.

  13. 49 CFR 236.202 - Signal governing movements over hand-operated switch.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... switch. 236.202 Section 236.202 Transportation Other Regulations Relating to Transportation (Continued...-operated switch. Signal governing movements over hand-operated switch in the facing direction shall display... over the switch in the normal and in the reverse position, the signal shall display its most...

  14. 49 CFR 236.202 - Signal governing movements over hand-operated switch.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... switch. 236.202 Section 236.202 Transportation Other Regulations Relating to Transportation (Continued...-operated switch. Signal governing movements over hand-operated switch in the facing direction shall display... over the switch in the normal and in the reverse position, the signal shall display its most...

  15. 49 CFR 236.202 - Signal governing movements over hand-operated switch.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... switch. 236.202 Section 236.202 Transportation Other Regulations Relating to Transportation (Continued...-operated switch. Signal governing movements over hand-operated switch in the facing direction shall display... over the switch in the normal and in the reverse position, the signal shall display its most...

  16. Comparison between the lumbar infusion and CSF tap tests to predict outcome after shunt surgery in suspected normal pressure hydrocephalus

    PubMed Central

    Kahlon, B; Sundbarg, G; Rehncrona, S

    2002-01-01

    Objective: To compare the lumbar infusion test and the cerebrospinal fluid (CSF) tap test for predicting the outcome of shunt surgery in patients with suspected normal pressure hydrocephalus. Methods: 68 patients with suspected normal pressure hydrocephalus were studied. The absence of preceding history indicated idiopathic disease in 75% of these. All patients were assessed twice with walking and psychometric tests before lumbar infusion test and tap test assessments. The lumbar infusion test was done using a constant infusion rate (0.80 ml/min) and regarded as positive if the steady state CSF plateau pressure reached levels of > 22 mm Hg (resistance to outflow > 14 mm Hg/ml/min). The tap test was regarded as positive if two or more of four different test items improved after CSF removal. As the variability in baseline test results was large, the better of two evaluations was used in comparisons with the results after CSF removal, as well as to evaluate the outcome after shunt surgery. Only patients with a positive lumbar infusion test or a positive tap test had surgery. Results: The results of the CSF tap test and the lumbar infusion test agreed in only 45% of the patients. Of the total cohort, 47 (69%) had positive test results and were operated on; 45 (96%) of these reported subjective improvement, and postoperative assessments verified the improvements in 38 (81%). Improvements were highly significant in walking, memory, and reaction time tests (p < 0.001). Most of the patients improved by surgery (84%) were selected by a positive lumbar infusion test, and only 42% by a positive tap test. Positive predictive values were 80% for lumbar infusion test and 94% for tap test. The false negative predictions in the operated group were much higher (58%) with the tap test than with the lumbar infusion test (16%). Conclusions: Both the lumbar infusion test and the tap test can predict a positive outcome of shunt operations in unselected patients with suspected normal pressure hydrocephalus. The two tests are complementary and should be used together for optimal patient selection. PMID:12438477

  17. Comparison between the lumbar infusion and CSF tap tests to predict outcome after shunt surgery in suspected normal pressure hydrocephalus.

    PubMed

    Kahlon, B; Sundbärg, G; Rehncrona, S

    2002-12-01

    To compare the lumbar infusion test and the cerebrospinal fluid (CSF) tap test for predicting the outcome of shunt surgery in patients with suspected normal pressure hydrocephalus. 68 patients with suspected normal pressure hydrocephalus were studied. The absence of preceding history indicated idiopathic disease in 75% of these. All patients were assessed twice with walking and psychometric tests before lumbar infusion test and tap test assessments. The lumbar infusion test was done using a constant infusion rate (0.80 ml/min) and regarded as positive if the steady state CSF plateau pressure reached levels of > 22 mm Hg (resistance to outflow > 14 mm Hg/ml/min). The tap test was regarded as positive if two or more of four different test items improved after CSF removal. As the variability in baseline test results was large, the better of two evaluations was used in comparisons with the results after CSF removal, as well as to evaluate the outcome after shunt surgery. Only patients with a positive lumbar infusion test or a positive tap test had surgery. The results of the CSF tap test and the lumbar infusion test agreed in only 45% of the patients. Of the total cohort, 47 (69%) had positive test results and were operated on; 45 (96%) of these reported subjective improvement, and postoperative assessments verified the improvements in 38 (81%). Improvements were highly significant in walking, memory, and reaction time tests (p < 0.001). Most of the patients improved by surgery (84%) were selected by a positive lumbar infusion test, and only 42% by a positive tap test. Positive predictive values were 80% for lumbar infusion test and 94% for tap test. The false negative predictions in the operated group were much higher (58%) with the tap test than with the lumbar infusion test (16%). Both the lumbar infusion test and the tap test can predict a positive outcome of shunt operations in unselected patients with suspected normal pressure hydrocephalus. The two tests are complementary and should be used together for optimal patient selection.

  18. Air Force Operational Test and Evaluation Center, Volume 2, Number 2

    DTIC Science & Technology

    1988-01-01

    the special class of attributes arc recorded, cost or In place of the normalization ( I). we propose beliefit. the lollowins normalization NUMERICAL ...comprchcnsi\\c set of modular basic data flow to meet requirements at test tools ,. designed to provide flexible data reduction start, then building to...possible. a totlinaion ot the two position error measurement techniques arc used SLR is a methd of fitting a linear model o accumlulate a position error

  19. [Detection of human papillomavirus (HVP) 16/18 infections of the vaginal uterine cervix in females before and following conisation].

    PubMed

    Götze, W; Jantschak, J; Kohls, A; Elling, D; Schildhaus, I

    1990-01-01

    280 women have been tested by FISH to detect an HPV 16/18-infection of the portio uteri. In a group of 133 women treated by conisation (all with a history of abnormal smear and colposcopy) 67 (50%) were positive for HPV 16/18 DNA before the operation. Follow up examinations of 20 cases with positive HPV 16/18 test before conisation, showed 6 and 12 months after operation only in 3 cases a persistence of HPV 16/18 infection. Only 5 (6.4%) of 78 women with a history of conisation and diagnosis CIN III some years ago were positive for HPV 16/18. In another group of 47 elderly women, treated by abrasio and with normal cervical histology, only 5 (10.6%) had a positive result in the HPV 16/18 FISH-test. 2 (10.6%) of 22 women with normal smear and colposcopy (control group) were positive for HPV 16/18.

  20. Internal combustion engine controls for reduced exhausts contaminants

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Matthews, D.R. Jr.

    1974-06-04

    An electrochemical control system for achieving optimum efficiency in the catalytic conversion of hydrocarbon and carbon monoxide emissions from internal combustion engines is described. The system automatically maintains catalyst temperature at a point for maximum pollutant conversion by adjusting ignition timing and fuel/air ratio during warm-up and subsequent operation. Ignition timing is retarded during engine warm-up to bring the catalytic converter to an efficient operating temperature within a minimum period of time. After the converter reaches a predetermined minimum temperature, the spark is advanced to within its normal operating range. A needle-valve adjustment during warm-up is employed to enrich themore » fuel/air mixture by approximately 10 percent. Following warm-up and attainment of a predetermined catalyst temperature, the needle valve is moved automatically to its normal position (e.g., a fuel/air ratio of 16:1). Although the normal lean mixture causes increased amounts of nitrogen oxide emissions, present NO/sub x/ converters appear capable of handling the increased emissions under normal operating conditions.« less

  1. 14 CFR 25.671 - General.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... electrical failure). (3) Any jam in a control position normally encountered during takeoff, climb, cruise... STANDARDS: TRANSPORT CATEGORY AIRPLANES Design and Construction Control Systems § 25.671 General. (a) Each control and control system must operate with the ease, smoothness, and positiveness appropriate to its...

  2. A characterization of positive linear maps and criteria of entanglement for quantum states

    NASA Astrophysics Data System (ADS)

    Hou, Jinchuan

    2010-09-01

    Let H and K be (finite- or infinite-dimensional) complex Hilbert spaces. A characterization of positive completely bounded normal linear maps from {\\mathcal B}(H) into {\\mathcal B}(K) is given, which particularly gives a characterization of positive elementary operators including all positive linear maps between matrix algebras. This characterization is then applied to give a representation of quantum channels (operations) between infinite-dimensional systems. A necessary and sufficient criterion of separability is given which shows that a state ρ on HotimesK is separable if and only if (ΦotimesI)ρ >= 0 for all positive finite-rank elementary operators Φ. Examples of NCP and indecomposable positive linear maps are given and are used to recognize some entangled states that cannot be recognized by the PPT criterion and the realignment criterion.

  3. [The influence of partial dorsal root rhizotomy on IGF-I expression in spared root ganglion and spinal cord].

    PubMed

    Wang, Wei-min; Guan, Yu-guang; Liu, Fen; Wang, Ting-hua; Xu, Xin-yun; Ke, Qing; Lu, Yong-chao; Yuan, Yuan

    2005-01-01

    To explore the temporospatial changes of IGF-I expression in the spared dorsal root ganglia (DRG, L6) on the operated side and un-operated side, in the spinal lamina II (L3, L5, L6) and Clarke's nucleus (L3) of the adult cats that have undergone partial dorsal rhizotomy, and compare them against those of the normal adult cats so as to unveil the relation between IGF-I and the plasticity of spinal cord. Fifteen male adult cats were divided into three groups. The cats of two groups were subjected to unilateral partial dorsal root rhizotomy (L1-L5, L7-S2 DRG were sectioned, but L6 was spared) and were sacrificed at 7 days and 14 days after operation. The bilateral L6 dorsal root ganglia and L3, L5, L6 spinal cord of all groups were made into frozen sections 20 microm thick. Then, the sections were stained by the immunohistochemistry ABC method using IGF-I (1:200, Santa Cruz) antibody. The distribution and the number of IGF-I positive neurons in bilateral spared DRG (L6) on the operated/un-operated side, in spinal lamina I (L3, L5, L6) and in Clarke' nucleus (L3) of each animal were observed and counted. All data were analyzed by one-way ANOVA, SNK-q test and paired-t test. (1) Seven days after partial dorsal root rhizotomy, the number of IGF-I positive neurons in spared DRG on the operated side declined as compared with that of normal group (P<0.05), but it was not significantly different from that of L6 spared DRG on the un-operated side (P>0.05). On the 14th day, the IGF-I expression in neurons of L6 DRG on the operated side was significantly lower than that of normal group and that of L6 spared DRG on the unoperated side (P<0.01), but it was not significantly different from that of the 7th day group (P>0.05). (2) There was no difference in number of IGF-I positive neuron in L3, L5, L6 spinal lamina II between normal group, 7th day post-operation group and 14th day post-operation group (P>0.05). After operation, IGF-I expression in Clarke's nucleus declined on the 7th day (P<0.05) and came back to normal level on the 14th day (P>0.05). Partial dorsal root rhizotomy can lead to the change of IGF-I expression in bilateral DRG and Clarke's nucleus, which suggests that IGF-I be related with spinal cord plasticity.

  4. Noninvasive prediction of shunt operation outcome in idiopathic normal pressure hydrocephalus

    PubMed Central

    Aoki, Yasunori; Kazui, Hiroaki; Tanaka, Toshihisa; Ishii, Ryouhei; Wada, Tamiki; Ikeda, Shunichiro; Hata, Masahiro; Canuet, Leonides; Katsimichas, Themistoklis; Musha, Toshimitsu; Matsuzaki, Haruyasu; Imajo, Kaoru; Kanemoto, Hideki; Yoshida, Tetsuhiko; Nomura, Keiko; Yoshiyama, Kenji; Iwase, Masao; Takeda, Masatoshi

    2015-01-01

    Idiopathic normal pressure hydrocephalus (iNPH) is a syndrome characterized by gait disturbance, cognitive deterioration and urinary incontinence in elderly individuals. These symptoms can be improved by shunt operation in some but not all patients. Therefore, discovering predictive factors for the surgical outcome is of great clinical importance. We used normalized power variance (NPV) of electroencephalography (EEG) waves, a sensitive measure of the instability of cortical electrical activity, and found significantly higher NPV in beta frequency band at the right fronto-temporo-occipital electrodes (Fp2, T4 and O2) in shunt responders compared to non-responders. By utilizing these differences, we were able to correctly identify responders and non-responders to shunt operation with a positive predictive value of 80% and a negative predictive value of 88%. Our findings indicate that NPV can be useful in noninvasively predicting the clinical outcome of shunt operation in patients with iNPH. PMID:25585705

  5. Valve for controlling solids flow

    DOEpatents

    Feldman, David K.

    1980-01-01

    A fluidized solids control valve is disclosed that is particularly well adapted for use with a flow of coal or char that includes both large particles and fines. The particles may or may not be fluidized at various times during the operation. The valve includes a tubular body that terminates in a valve seat covered by a normally closed closure plate. The valve body at the seat and the closure plate is provided with aligned longitudinal slots that receive a pivotally supported key plate. The key plate is positionable by an operator in inserted, intermediate and retracted positions respecting the longitudinal slot in the valve body. The key plate normally closes the slot within the closure plate but is shaped and aligned obliquely to the longitudinal slot within the valve body to provide progressively increasing slot openings between the inserted and retracted positions. Transfer members are provided between the operator, key plate and closure plate to move the closure plate into an open position only when the key plate is retracted from the longitudinal slot within the valve body.

  6. 30 CFR 70.220 - Status change reports.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... to all miners expected to wear a CPDM. The training shall be completed prior to a miner wearing a... cutting machine. On the cutting machine operator or on the cutting machine within 36 inches inby the normal working position; (2) Conventional section blasting off the solid. On the loading machine operator...

  7. 30 CFR 70.207 - Bimonthly sampling; mechanized mining units.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... sampling device as follows: (1) Conventional section using cutting machine. On the cutting machine operator or on the cutting machine within 36 inches inby the normal working position; (2) Conventional section shooting off the solid. On the loading machine operator or on the loading machine within 36 inches inby the...

  8. 30 CFR 70.207 - Bimonthly sampling; mechanized mining units.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... sampling device as follows: (1) Conventional section using cutting machine. On the cutting machine operator or on the cutting machine within 36 inches inby the normal working position; (2) Conventional section shooting off the solid. On the loading machine operator or on the loading machine within 36 inches inby the...

  9. 30 CFR 70.207 - Bimonthly sampling; mechanized mining units.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... sampling device as follows: (1) Conventional section using cutting machine. On the cutting machine operator or on the cutting machine within 36 inches inby the normal working position; (2) Conventional section shooting off the solid. On the loading machine operator or on the loading machine within 36 inches inby the...

  10. Using a Six Sigma Fishbone Analysis Approach To Evaluate the Effect of Extreme Weather Events on Salmonella Positives in Young Chicken Slaughter Establishments.

    PubMed

    Linville, John W; Schumann, Douglas; Aston, Christopher; Defibaugh-Chavez, Stephanie; Seebohm, Scott; Touhey, Lucy

    2016-12-01

    A six sigma fishbone analysis approach was used to develop a machine learning model in SAS, Version 9.4, by using stepwise linear regression. The model evaluated the effect of a wide variety of variables, including slaughter establishment operational measures, normal (30-year average) weather, and extreme weather events on the rate of Salmonella -positive carcasses in young chicken slaughter establishments. Food Safety and Inspection Service (FSIS) verification carcass sampling data, as well as corresponding data from the National Oceanographic and Atmospheric Administration and the Federal Emergency Management Agency, from September 2011 through April 2015, were included in the model. The results of the modeling show that in addition to basic establishment operations, normal weather patterns, differences from normal and disaster events, including time lag weather and disaster variables, played a role in explaining the Salmonella percent positive that varied by slaughter volume quartile. Findings show that weather and disaster events should be considered as explanatory variables when assessing pathogen-related prevalence analysis or research and slaughter operational controls. The apparent significance of time lag weather variables suggested that at least some of the impact on Salmonella rates occurred after the weather events, which may offer opportunities for FSIS or the poultry industry to implement interventions to mitigate those effects.

  11. [Impact of acupuncture to IGF-I expression in spared dorsal root ganglion of cats].

    PubMed

    Liu, Fen; Wang, Ting-Hua; Zhang, Yi; Hong, Sun-quan; Song, Xin-bo

    2006-05-01

    To explore the relationship between Insulin-like growth factor-I (IGF-I) and acupuncture promoting the spinal cord plasticity, the changes of IGF- I expressing in spared dorsal root ganglia (DRG,L6) after operation and acupuncture were investigated. 25 adult cats were divided into 5 groups: normal control group; 7th day and 14th day group after unilateral partial rhizotomy (unilateral L1-L5,L7-S2 DRG Were transected, but L6 DRG was spared); 7th day and 14th day group of acupuncture stimulating the spared DRG (electro-needle stimulation was performed by following unilateral partial root rhizotomy). Animals survived for 7 or 14 days after operation respectively. Unilateral L6 dorsal root ganglia of each group were made into 20 microm frozen sections. By immunohistochemistry ABC method, the sections were stained with specific IGF-I (1:200) antibody. The distribution and the number of IGF-I positive neurons in spared DRG (L6) that located the operated/acupuncture side of each animal were observed and counted. For 7th day group after acupuncture stiumlation, the number of IGF-I positive neurons of spared DRG of acupuncture side showed significantly more than that of 7th day operation group (P<0.05), but still less than that of normal group (P < 0.05); In 14th day group, IGF- I expression in neuron of L6 DRG also increased apparently more than that of 14th day operation group, with coming back to normal level. After acupuncture stimulating the spared DRG for 14 days, the numbers of IGF- I positive neurons in spared DRG increased significantly more than that of 7th day group after acupuncture (P<0.05). Acupuncture can significantly increase the number of IGF- I positive neurons. Our results indicate that the expression changes of IGF-I in spared DRG associate with acupuncture promoting the spinal cord plasticity.

  12. Passive decay heat removal system for water-cooled nuclear reactors

    DOEpatents

    Forsberg, Charles W.

    1991-01-01

    A passive decay-heat removal system for a water-cooled nuclear reactor employs a closed heat transfer loop having heat-exchanging coils inside an open-topped, insulated box located inside the reactor vessel, below its normal water level, in communication with a condenser located outside of containment and exposed to the atmosphere. The heat transfer loop is located such that the evaporator is in a position where, when the water level drops in the reactor, it will become exposed to steam. Vapor produced in the evaporator passes upward to the condenser above the normal water level. In operation, condensation in the condenser removes heat from the system, and the condensed liquid is returned to the evaporator. The system is disposed such that during normal reactor operations where the water level is at its usual position, very little heat will be removed from the system, but during emergency, low water level conditions, substantial amounts of decay heat will be removed.

  13. Assessment of specific energy absorption rate (SAR) in the head from a TETRA handset.

    PubMed

    Dimbylow, Peter; Khalid, Mohammed; Mann, Simon

    2003-12-07

    Finite-difference time-domain (FDTD) calculations of the specific energy absorption rate (SAR) from a representative TETRA handset have been performed in an anatomically realistic model of the head. TETRA (Terrestrial Trunked Radio) is a modern digital private mobile radio system designed to meet the requirements of professional users, such as the police and fire brigade. The current frequency allocations in the UK are 380-385 MHz and 390-395 MHz for the public sector network. A comprehensive set of calculations of SAR in the head was performed for positions of the handset in front of the face and at both sides of the head. The representative TETRA handset considered. operating at 1 W in normal use, will show compliance with both the ICNIRP occupational and public exposure restrictions. The handset with a monopole antenna operating at 3 W in normal use will show compliance with both the ICNIRP occupational and public exposure restrictions. The handset with a helical antenna operating at 3 W in normal use will show compliance with the ICNIRP occupational exposure restriction but will be over the public exposure restriction by up to approximately 50% if kept in the position of maximum SAR for 6 min continuously.

  14. Performance of Thermal Mass Flow Meters in a Variable Gravitational Environment

    NASA Technical Reports Server (NTRS)

    Brooker, John E.; Ruff, Gary A.

    2004-01-01

    The performance of five thermal mass flow meters, MKS Instruments 179A and 258C, Unit Instruments UFM-8100, Sierra Instruments 830L, and Hastings Instruments HFM-200, were tested on the KC-135 Reduced Gravity Aircraft in orthogonal, coparallel, and counterparallel orientations relative to gravity. Data was taken throughout the parabolic trajectory where the g-level varied from 0.01 to 1.8 times normal gravity. Each meter was calibrated in normal gravity in the orthogonal position prior to flight followed by ground testing at seven different flow conditions to establish a baseline operation. During the tests, the actual flow rate was measured independently using choked-flow orifices. Gravitational acceleration and attitude had a unique effect on the performance of each meter. All meters operated within acceptable limits at all gravity levels in the calibrated orthogonal position. However, when operated in other orientations, the deviations from the reference flow became substantial for several of the flow meters. Data analysis indicated that the greatest source of error was the effect of orientation, followed by the gravity level. This work emphasized that when operating thermal flow meters in a variable gravity environment, it is critical to orient the meter in the same direction relative to gravity in which it was calibrated. Unfortunately, there was no test in normal gravity that could predict the performance of a meter in reduced gravity. When operating in reduced gravity, all meters indicated within 5 percent of the full scale reading at all flow conditions and orientations.

  15. Remote manual operator for space station intermodule ventilation valve

    NASA Technical Reports Server (NTRS)

    Guyaux, James R.

    1996-01-01

    The Remote Manual Operator (RMO) is a mechanism used for manual operation of the Space Station Intermodule Ventilation (IMV) valve and for visual indication of valve position. The IMV is a butterfly-type valve, located in the ventilation or air circulation ducts of the Space Station, and is used to interconnect or isolate the various compartments. The IMV valve is normally operated by an electric motor-driven actuator under computer or astronaut control, but it can also be operated manually with the RMO. The IMV valve RMO consists of a handle with a deployment linkage, a gear-driven flexible shaft, and a linkage to disengage the electric motor actuator during manual operation. It also provides visual indication of valve position. The IMV valve RMO is currently being prepared for qualification testing.

  16. 40 CFR 63.1041 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... foam- or liquid-filled continuous seal that is mounted between the wall of the separator and the... safety device is designed to remain in a closed position during normal operations and open only when the...

  17. 40 CFR 63.1041 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... foam- or liquid-filled continuous seal that is mounted between the wall of the separator and the... safety device is designed to remain in a closed position during normal operations and open only when the...

  18. 40 CFR 63.1041 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... foam- or liquid-filled continuous seal that is mounted between the wall of the separator and the... safety device is designed to remain in a closed position during normal operations and open only when the...

  19. 40 CFR 63.1041 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... foam- or liquid-filled continuous seal that is mounted between the wall of the separator and the... safety device is designed to remain in a closed position during normal operations and open only when the...

  20. 40 CFR 63.1041 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... foam- or liquid-filled continuous seal that is mounted between the wall of the separator and the... safety device is designed to remain in a closed position during normal operations and open only when the...

  1. Optical techniques for determination of normal shock position in supersonic flows for aerospace applications

    NASA Technical Reports Server (NTRS)

    Adamovsky, Grigory; Eustace, John G.

    1990-01-01

    Techniques for the quantitative determination of shock position in supersonic flows using direct and indirect methods is presented. A description of an experimental setup is also presented, different configurations of shock position sensing systems are explained, and some experimental results are given. All of the methods discussed are analyzed to determine the ease of technology transfer from the laboratory to in-flight operation.

  2. 40 CFR 265.1081 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... complete contact with it) inside a tank that has a fixed roof. Liquid-mounted seal means a foam or liquid... fluctuations. A safety device is designed to remain in a closed position during normal operations and open only...

  3. 40 CFR 265.1081 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... complete contact with it) inside a tank that has a fixed roof. Liquid-mounted seal means a foam or liquid... fluctuations. A safety device is designed to remain in a closed position during normal operations and open only...

  4. 40 CFR 265.1081 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... complete contact with it) inside a tank that has a fixed roof. Liquid-mounted seal means a foam or liquid... fluctuations. A safety device is designed to remain in a closed position during normal operations and open only...

  5. 40 CFR 265.1081 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... complete contact with it) inside a tank that has a fixed roof. Liquid-mounted seal means a foam or liquid... fluctuations. A safety device is designed to remain in a closed position during normal operations and open only...

  6. 40 CFR 265.1081 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... complete contact with it) inside a tank that has a fixed roof. Liquid-mounted seal means a foam or liquid... fluctuations. A safety device is designed to remain in a closed position during normal operations and open only...

  7. The Value of Visa-Score and Colour Flow Imaging in the Follow-Up of Non-Athletes Operated for Jumpers Knee.

    PubMed

    Salvesen, Eirik S; Holen, Ketil J

    2016-12-01

    The objective of this study was to assess if the Victorian Institute of Sport Assessment (VISA) questionnaire was suitable in the evaluation of patients from a mixed population with normal levels of sports activity, and if neovascularization of the patellar tendon demonstrated by color flow imaging (CFI) was more frequent in patients with lasting symptoms after surgical treatment for jumpers knee (JK). This study was conducted at St. Olavs Hospital, University Hospital of Trondheim, Norway, and included 21 men and 18 women who were operated for JK. Symptoms were assessed using the Knee Injury and Osteoarthritis Outcome Score (KOOS) and VISA questionnaires. Clinical and ultrasonographic examinations of the knees, including CFI, were done at a mean follow-up duration of 82 (range, 16-136) months after surgery. Patients with positive CFI also had significantly lower KOOS scores, whereas the total VISA-P (Victorian Institute of Sport Assessment - Patella) score showed no association. Patients with a positive clinical examination had significantly more frequent positive CFI findings than did patients with negative examinations. The operated patellar tendon was significantly thicker and had more frequent hypoechoic signal in the proximal part than the contralateral unoperated tendon. The post-operative VISA-P score seems less valuable in the evaluation of patients from a mixed population with normal levels of sports activity. CFI may be a valuable diagnostic tool in the evaluation of patients operated for JK.

  8. Efficacy and safety of the trans-obturator TVT-Abbrevo device in normal weight compared to overweight patients affected by stress urinary incontinence.

    PubMed

    Tommaselli, Giovanni A; Napolitano, Valerio; Di Carlo, Costantino; Formisano, Carmen; Fabozzi, Annamaria; Nappi, Carmine

    2016-02-01

    To investigate if TVT-Abbrevo has similar outcomes in normal weight and overweight patients. Retrospective evaluation of 205 (105 normal weight women and 100 overweight women with BMI ≥ 25 kg/m(2)) undergone TVT-Abbrevo positioning with 12 month follow-up. Primary outcomes were objective cure rate (defined as no leakage during CST) and subjective cure rate ("very much improved"/"much improved" at PGI-I), secondary outcomes were intra-operative and post-operative complications. Objective cure rates in the normal and overweight groups were 96.2% and 94%, respectively (p=.47). Subjective cure rates in the normal and overweight groups were 90.5% and 88%, respectively (p=.57). ICIQ-SF, I-QoL and PGI-S scores significantly improved in both groups with no differences between the two groups. No serious intra- or post-operative complications were observed. No differences were observed in pain VAS scores and number of analgesic vials administered. TVT-Abbrevo seems to have similar efficacy and safety in normal weight and overweight women. More studies are needed to assess the efficacy of this device in frankly obese women and long-term outcomes. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  9. The operation was a success, but the patient cannot see.

    PubMed

    Semmer, Anne E; Lee, Michael S; Taban, Mehran; Smith, Scott; Kosmorsky, Gregory

    2009-01-01

    A 71-year-old African American woman presented with severe vision loss in her left eye one day following trabeculectomy with mitomycin C and retrobulbar anesthesia. She had a new left relative afferent pupillary defect and macular whitening. The optic disc appeared normal. Intraocular pressure and fluorescein angiography were normal. Westergren erythrocyte sedimentation rate and C-reactive protein were elevated. Temporal artery biopsy was positive for giant cell arteritis.

  10. Music and the reduction of post-operative pain.

    PubMed

    Dunn, Kelly

    The prevention and treatment of post-operative pain, and the promotion of comfort are the challenges facing practitioners working in the recovery room setting. Surgical pain produces autonomic, psychological, immunological and behavioural responses that can delay or inhibit normal healing. Nurses spend more time with patients experiencing pain than any other healthcare professional. Therefore, they are in an ideal position to consider other pain-relieving strategies to complement the analgesics currently used. The studies reviewed cannot prove that music is effective in reducing post-operative pain, because the research methodology in the majority is poor. Patients, experience of listening to music post-operatively was positive, aiding distraction and increasing comfort. This shows the difference between inconsistent results for the objective measures of pain and what the patient is reporting.

  11. Douglas flight deck design philosophy

    NASA Technical Reports Server (NTRS)

    Oldale, Paul

    1990-01-01

    The systems experience gained from 17 years of DC-10 operation was used during the design of the MD-11 to automate system operation and reduce crew workload. All functions, from preflight to shutdown at the termination of flight, require little input from the crew. The MD-11 aircraft systems are monitored for proper operation by the Aircraft Systems Controllers (ASC). In most cases, system reconfiguration as a result of a malfunction is automated. Manual input is required for irreversible actions such as engine shutdown, fuel dump, fire agent discharge, or Integrated Drive Generator (IDG) disconnect. During normal operations, when the cockpit is configured for flight, all annunciators on the overhead panel will be extinguished. This Dark Cockpit immediately confirms to the crew that the panels are correctly configured and that no abnormalities are present. Primary systems annunciations are shown in text on the Alert Area of the Engine and Alert Display (EAD). This eliminates the need to scan the overhead. The MD-11 aircraft systems can be manually controlled from the overhead area of the cockpit. The center portion of the overhead panel is composed of the primary aircraft systems panels, which include FUEL, AIR, Electrical (ELEC) and Hydraulic (HYD) systems, which are easily accessible from both flight crew positions. Each Aircraft Systems Controller (ASC) has two automatic channels and a manual mode. All rectangular lights are annunciators. All square lights are combined switches and annunciators called switch/lights. Red switch/lights on the overhead (Level 3 alerts) are for conditions requiring immediate crew action. Amber (Level 2 or Level 1 alerts) indicates a fault or switch out of position requiring awareness or crew interaction. Overhead switches used in normal operating conditions will illuminate blue when in use (Level 0 alerts) such as WING ANTI-ICE - ON. An overhead switch/light with BLACK LETTERING on an amber or red background indicates a system failure and that crew interaction is required. A switch/light with blue or amber lettering and a BLACK BACKGROUND indicates a switch out of normal position and that crew action is necessary only if the system is in manual operation.

  12. 14 CFR 23.671 - General.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Design and Construction Control Systems § 23.671 General. (a) Each control must operate easily, smoothly, and positively enough to allow proper performance of its functions. (b) Controls must be arranged and identified to provide for...

  13. 14 CFR 23.671 - General.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Design and Construction Control Systems § 23.671 General. (a) Each control must operate easily, smoothly, and positively enough to allow proper performance of its functions. (b) Controls must be arranged and identified to provide for...

  14. 14 CFR 23.671 - General.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Design and Construction Control Systems § 23.671 General. (a) Each control must operate easily, smoothly, and positively enough to allow proper performance of its functions. (b) Controls must be arranged and identified to provide for...

  15. 14 CFR 23.671 - General.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Design and Construction Control Systems § 23.671 General. (a) Each control must operate easily, smoothly, and positively enough to allow proper performance of its functions. (b) Controls must be arranged and identified to provide for...

  16. 14 CFR 23.671 - General.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Design and Construction Control Systems § 23.671 General. (a) Each control must operate easily, smoothly, and positively enough to allow proper performance of its functions. (b) Controls must be arranged and identified to provide for...

  17. Discovery of Novel Mammary Developmental and Cancer Genes Using ENU Mutagenesis

    DTIC Science & Technology

    2002-10-01

    death rates we need new therapeutic targets, currently a major challenge facing cancer researchers This requires an understanding of the undiscovered pathways that operate to drive breast cancer cell proliferation, cell survival and cell differentiation, pathways which are also likely to operate during normal mammary development, and which go awry in cancer The discovery of signalling pathways operative in breast cancer has utilised examination of mammary gland development following systemic endocrine ablation or viral insertion, positional cloning in affected families and

  18. NASCAP modelling of high-voltage power system interactions with space charged-particle environments

    NASA Technical Reports Server (NTRS)

    Stevens, N. J.; Roche, J. C.; Mandell, M. J.

    1979-01-01

    A simple space power system operating in geosynchronous orbit was analyzed. This system consisted of two solar array wings and a central body. Each solar array wing was considered to be divided into three regions operating at 2000 volts. The center body was considered to be an electrical ground with the array voltages both positive and negative relative to ground. The system was analyzed for both a normal environment and a moderate geomagnetic substorm environment. Initial results indicate a high probability of arcing at the interconnects on the negative operating voltage wing. The dielectric strength of the substrate may be exceeded giving rise to breakdown in the bulk of the material. The geomagnetic substorm did not seem to increase the electrical gradients at the interconnects on the negative operating voltage wing but did increase the gradients on the positive operating voltage wing which could result in increased coupling current losses.

  19. 14 CFR 27.671 - General.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... STANDARDS: NORMAL CATEGORY ROTORCRAFT Design and Construction Control Systems § 27.671 General. (a) Each control and control system must operate with the ease, smoothness, and positiveness appropriate to its function. (b) Each element of each flight control system must be designed, or distinctively and permanently...

  20. 14 CFR 27.671 - General.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... STANDARDS: NORMAL CATEGORY ROTORCRAFT Design and Construction Control Systems § 27.671 General. (a) Each control and control system must operate with the ease, smoothness, and positiveness appropriate to its function. (b) Each element of each flight control system must be designed, or distinctively and permanently...

  1. 14 CFR 27.671 - General.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... STANDARDS: NORMAL CATEGORY ROTORCRAFT Design and Construction Control Systems § 27.671 General. (a) Each control and control system must operate with the ease, smoothness, and positiveness appropriate to its function. (b) Each element of each flight control system must be designed, or distinctively and permanently...

  2. 14 CFR 27.671 - General.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... STANDARDS: NORMAL CATEGORY ROTORCRAFT Design and Construction Control Systems § 27.671 General. (a) Each control and control system must operate with the ease, smoothness, and positiveness appropriate to its function. (b) Each element of each flight control system must be designed, or distinctively and permanently...

  3. 14 CFR 27.671 - General.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... STANDARDS: NORMAL CATEGORY ROTORCRAFT Design and Construction Control Systems § 27.671 General. (a) Each control and control system must operate with the ease, smoothness, and positiveness appropriate to its function. (b) Each element of each flight control system must be designed, or distinctively and permanently...

  4. 47 CFR 90.463 - Transmitter control points.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ....463 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES.... (b) Each station or licensed system of communication shall normally have a control point, or control... fixed position in a system of communication at or from which the control operator exercises supervision...

  5. Cointegration as a data normalization tool for structural health monitoring applications

    NASA Astrophysics Data System (ADS)

    Harvey, Dustin Y.; Todd, Michael D.

    2012-04-01

    The structural health monitoring literature has shown an abundance of features sensitive to various types of damage in laboratory tests. However, robust feature extraction in the presence of varying operational and environmental conditions has proven to be one of the largest obstacles in the development of practical structural health monitoring systems. Cointegration, a technique adapted from the field of econometrics, has recently been introduced to the SHM field as one solution to the data normalization problem. Response measurements and feature histories often show long-run nonstationarity due to fluctuating temperature, load conditions, or other factors that leads to the occurrence of false positives. Cointegration theory allows nonstationary trends common to two or more time series to be modeled and subsequently removed. Thus, the residual retains sensitivity to damage with dependence on operational and environmental variability removed. This study further explores the use of cointegration as a data normalization tool for structural health monitoring applications.

  6. 40 CFR 61.341 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... open to the atmosphere and is composed of piping, ductwork, connections, and, if necessary, flow... foam or liquid-filled primary seal mounted in contact with the liquid between the waste management unit... to remain in a closed position during normal operations and open only when the internal pressure, or...

  7. 40 CFR 61.341 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... open to the atmosphere and is composed of piping, ductwork, connections, and, if necessary, flow... foam or liquid-filled primary seal mounted in contact with the liquid between the waste management unit... to remain in a closed position during normal operations and open only when the internal pressure, or...

  8. 40 CFR 61.341 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... open to the atmosphere and is composed of piping, ductwork, connections, and, if necessary, flow... foam or liquid-filled primary seal mounted in contact with the liquid between the waste management unit... to remain in a closed position during normal operations and open only when the internal pressure, or...

  9. 40 CFR 61.341 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... open to the atmosphere and is composed of piping, ductwork, connections, and, if necessary, flow... foam or liquid-filled primary seal mounted in contact with the liquid between the waste management unit... to remain in a closed position during normal operations and open only when the internal pressure, or...

  10. 14 CFR 23.937 - Turbopropeller-drag limiting systems.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... actuated after engine power loss, can move the propeller blades toward the feather position to reduce... General § 23.937 Turbopropeller-drag limiting systems. (a) Turbopropeller-powered airplane propeller-drag... normal or emergency operation results in propeller drag in excess of that for which the airplane was...

  11. 14 CFR 23.937 - Turbopropeller-drag limiting systems.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... actuated after engine power loss, can move the propeller blades toward the feather position to reduce... General § 23.937 Turbopropeller-drag limiting systems. (a) Turbopropeller-powered airplane propeller-drag... normal or emergency operation results in propeller drag in excess of that for which the airplane was...

  12. 14 CFR 23.937 - Turbopropeller-drag limiting systems.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... actuated after engine power loss, can move the propeller blades toward the feather position to reduce... General § 23.937 Turbopropeller-drag limiting systems. (a) Turbopropeller-powered airplane propeller-drag... normal or emergency operation results in propeller drag in excess of that for which the airplane was...

  13. 14 CFR 23.937 - Turbopropeller-drag limiting systems.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... actuated after engine power loss, can move the propeller blades toward the feather position to reduce... General § 23.937 Turbopropeller-drag limiting systems. (a) Turbopropeller-powered airplane propeller-drag... normal or emergency operation results in propeller drag in excess of that for which the airplane was...

  14. 14 CFR 23.937 - Turbopropeller-drag limiting systems.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... actuated after engine power loss, can move the propeller blades toward the feather position to reduce... General § 23.937 Turbopropeller-drag limiting systems. (a) Turbopropeller-powered airplane propeller-drag... normal or emergency operation results in propeller drag in excess of that for which the airplane was...

  15. Boiling water neutronic reactor incorporating a process inherent safety design

    DOEpatents

    Forsberg, C.W.

    1985-02-19

    A boiling-water reactor core is positioned within a prestressed concrete reactor vessel of a size which will hold a supply of coolant water sufficient to submerge and cool the reactor core by boiling for a period of at least one week after shutdown. Separate volumes of hot, clean (nonborated) water for cooling during normal operation and cool highly borated water for emergency cooling and reactor shutdown are separated by an insulated wall during normal reactor operation with contact between the two water volumes being maintained at interfaces near the top and bottom ends of the reactor vessel. Means are provided for balancing the pressure of the two water volumes at the lower interface zone during normal operation to prevent entry of the cool borated water into the reactor core region, for detecting the onset of excessive power to coolant flow conditions in the reactor core and for detecting low water levels of reactor coolant. Cool borated water is permitted to flow into the reactor core when low reactor coolant levels or excessive power to coolant flow conditions are encountered.

  16. Boiling water neutronic reactor incorporating a process inherent safety design

    DOEpatents

    Forsberg, Charles W.

    1987-01-01

    A boiling-water reactor core is positioned within a prestressed concrete reactor vessel of a size which will hold a supply of coolant water sufficient to submerge and cool the reactor core by boiling for a period of at least one week after shutdown. Separate volumes of hot, clean (non-borated) water for cooling during normal operation and cool highly borated water for emergency cooling and reactor shutdown are separated by an insulated wall during normal reactor operation with contact between the two water volumes being maintained at interfaces near the top and bottom ends of the reactor vessel. Means are provided for balancing the pressure of the two volumes at the lower interface zone during normal operation to prevent entry of the cool borated water into the reactor core region, for detecting the onset of excessive power to coolant flow conditions in the reactor core and for detecting low water levels of reactor coolant. Cool borated water is permitted to flow into the reactor core when low reactor coolant levels or excessive power to coolant flow conditions are encountered.

  17. The Use of ATP-MgCl2 in the Treatment of Injury and Shock.

    DTIC Science & Technology

    1986-03-11

    that it requires mitochondrially produced ATP for its operation. Studies of the hemodynamic effects of ATP-MgCl 2 infusion in anesthetized normal and...8-14 1. LUNG STUDIES a) The salutary effects of positive end-expiratory pressure (PEEP) in experimentally-induced Pseudomonas pneumonia...salutary effects of positive end-expiratory pressure (PEEP) in experimentally induced Pseudomonas pneumonia." Anesthesia and Analgesia 58:2C8-215, 1979. 37

  18. Planning and Scheduling of Payloads of AstroSat During Initial and Normal Phase Observations

    NASA Astrophysics Data System (ADS)

    Pandiyan, R.; Subbarao, S. V.; Nagamani, T.; Rao, Chaitra; Rao, N. Hari Prasad; Joglekar, Harish; Kumar, Naresh; Dumpa, Surya Ratna Prakash; Chauhan, Anshu; Dakshayani, B. P.

    2017-06-01

    On 28th September 2015, India launched its first astronomical space observatory AstroSat, successfully. AstroSat carried five astronomy payloads, namely, (i) Cadmium Zinc Telluride Imager (CZTI), (ii) Large Area X-ray Proportional Counter (LAXPC), (iii) Soft X-ray Telescope (SXT), (iv) Ultra Violet Imaging Telescope (UVIT) and (v) Scanning Sky Monitor (SSM) and therefore, has the capability to observe celestial objects in multi-wavelength. Four of the payloads are co-aligned along the positive roll axis of the spacecraft and the remaining one is placed along the positive yaw axis direction. All the payloads are sensitive to bright objects and specifically, require avoiding bright Sun within a safe zone of their bore axes in orbit. Further, there are other operational constraints both from spacecraft side and payloads side which are to be strictly enforced during operations. Even on-orbit spacecraft manoeuvres are constrained to about two of the axes in order to avoid bright Sun within this safe zone and a special constrained manoeuvre is exercised during manoeuvres. The planning and scheduling of the payloads during the Performance Verification (PV) phase was carried out in semi-autonomous/manual mode and a complete automation is exercised for normal phase/Guaranteed Time Observation (GuTO) operations. The process is found to be labour intensive and several operational software tools, encompassing spacecraft sub-systems, on-orbit, domain and environmental constraints, were built-in and interacted with the scheduling tool for appropriate decision-making and science scheduling. The procedural details of the complex scheduling of a multi-wavelength astronomy space observatory and their working in PV phase and in normal/GuTO phases are presented in this paper.

  19. 30 CFR 70.207 - Bimonthly sampling; mechanized mining units.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... air will be used to determine the average concentration for that mechanized mining unit. (e) Unless... sampling device as follows: (1) Conventional section using cutting machine. On the cutting machine operator or on the cutting machine within 36 inches inby the normal working position; (2) Conventional section...

  20. Method for automatically scramming a nuclear reactor

    DOEpatents

    Ougouag, Abderrafi M.; Schultz, Richard R.; Terry, William K.

    2005-12-27

    An automatically scramming nuclear reactor system. One embodiment comprises a core having a coolant inlet end and a coolant outlet end. A cooling system operatively associated with the core provides coolant to the coolant inlet end and removes heated coolant from the coolant outlet end, thus maintaining a pressure differential therebetween during a normal operating condition of the nuclear reactor system. A guide tube is positioned within the core with a first end of the guide tube in fluid communication with the coolant inlet end of the core, and a second end of the guide tube in fluid communication with the coolant outlet end of the core. A control element is positioned within the guide tube and is movable therein between upper and lower positions, and automatically falls under the action of gravity to the lower position when the pressure differential drops below a safe pressure differential.

  1. Bootstrap position analysis for forecasting low flow frequency

    USGS Publications Warehouse

    Tasker, Gary D.; Dunne, P.

    1997-01-01

    A method of random resampling of residuals from stochastic models is used to generate a large number of 12-month-long traces of natural monthly runoff to be used in a position analysis model for a water-supply storage and delivery system. Position analysis uses the traces to forecast the likelihood of specified outcomes such as reservoir levels falling below a specified level or streamflows falling below statutory passing flows conditioned on the current reservoir levels and streamflows. The advantages of this resampling scheme, called bootstrap position analysis, are that it does not rely on the unverifiable assumption of normality, fewer parameters need to be estimated directly from the data, and accounting for parameter uncertainty is easily done. For a given set of operating rules and water-use requirements for a system, water managers can use such a model as a decision-making tool to evaluate different operating rules. ?? ASCE,.

  2. Quantum mechanics of a photon

    NASA Astrophysics Data System (ADS)

    Babaei, Hassan; Mostafazadeh, Ali

    2017-08-01

    A first-quantized free photon is a complex massless vector field A =(Aμ ) whose field strength satisfies Maxwell's equations in vacuum. We construct the Hilbert space H of the photon by endowing the vector space of the fields A in the temporal-Coulomb gauge with a positive-definite and relativistically invariant inner product. We give an explicit expression for this inner product, identify the Hamiltonian for the photon with the generator of time translations in H , determine the operators representing the momentum and the helicity of the photon, and introduce a chirality operator whose eigenfunctions correspond to fields having a definite sign of energy. We also construct a position operator for the photon whose components commute with each other and with the chirality and helicity operators. This allows for the construction of the localized states of the photon with a definite sign of energy and helicity. We derive an explicit formula for the latter and compute the corresponding electric and magnetic fields. These turn out to diverge not just at the point where the photon is localized but on a plane containing this point. We identify the axis normal to this plane with an associated symmetry axis and show that each choice of this axis specifies a particular position operator, a corresponding position basis, and a position representation of the quantum mechanics of a photon. In particular, we examine the position wave functions determined by such a position basis, elucidate their relationship with the Riemann-Silberstein and Landau-Peierls wave functions, and give an explicit formula for the probability density of the spatial localization of the photon.

  3. Selected Design Parameters for Reclining Seats Based on Engineering Anthropometry

    DTIC Science & Technology

    1977-09-01

    mounted on these arm rests and immediately adjacent surfaces -provide upper extremity configuratinns conducive to maximum biomechanical advantage -meet...operation at the rudder pedals under normal or under high G environments. (2) Size: The foot rest must be large enough to cover the range of heel positions...See Figure 9.) Foot Control Adjustment Two horizontal cylinders 2" in diameter x 6" long represented rudder pedals to be operated by feet. They were

  4. Classification of mass and normal breast tissue: A convolution neural network classifier with spatial domain and texture images

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sahiner, B.; Chan, H.P.; Petrick, N.

    1996-10-01

    The authors investigated the classification of regions of interest (ROI`s) on mammograms as either mass or normal tissue using a convolution neural network (CNN). A CNN is a back-propagation neural network with two-dimensional (2-D) weight kernels that operate on images. A generalized, fast and stable implementation of the CNN was developed. The input images to the CNN were obtained form the ROI`s using two techniques. The first technique employed averaging and subsampling. The second technique employed texture feature extraction methods applied to small subregions inside the ROI. Features computed over different subregions were arranged as texture images, which were subsequentlymore » used as CNN inputs. The effects of CNN architecture and texture feature parameters on classification accuracy were studied. Receiver operating characteristic (ROC) methodology was used to evaluate the classification accuracy. A data set consisting of 168 ROI`s containing biopsy-proven masses and 504 ROI`s containing normal breast tissue was extracted from 168 mammograms by radiologists experienced in mammography. This data set was used for training and testing the CNN. With the best combination of CNN architecture and texture feature parameters, the area under the test ROC curve reached 0.87, which corresponded to a true-positive fraction of 90% at a false positive fraction of 31%. The results demonstrate the feasibility of using a CNN for classification of masses and normal tissue on mammograms.« less

  5. Standard operation procedures for conducting the on-the-road driving test, and measurement of the standard deviation of lateral position (SDLP)

    PubMed Central

    Verster, Joris C; Roth, Thomas

    2011-01-01

    This review discusses the methodology of the standardized on-the-road driving test and standard operation procedures to conduct the test and analyze the data. The on-the-road driving test has proven to be a sensitive and reliable method to examine driving ability after administration of central nervous system (CNS) drugs. The test is performed on a public highway in normal traffic. Subjects are instructed to drive with a steady lateral position and constant speed. Its primary parameter, the standard deviation of lateral position (SDLP), ie, an index of ‘weaving’, is a stable measure of driving performance with high test–retest reliability. SDLP differences from placebo are dose-dependent, and do not depend on the subject’s baseline driving skills (placebo SDLP). It is important that standard operation procedures are applied to conduct the test and analyze the data in order to allow comparisons between studies from different sites. PMID:21625472

  6. Standard operation procedures for conducting the on-the-road driving test, and measurement of the standard deviation of lateral position (SDLP).

    PubMed

    Verster, Joris C; Roth, Thomas

    2011-01-01

    This review discusses the methodology of the standardized on-the-road driving test and standard operation procedures to conduct the test and analyze the data. The on-the-road driving test has proven to be a sensitive and reliable method to examine driving ability after administration of central nervous system (CNS) drugs. The test is performed on a public highway in normal traffic. Subjects are instructed to drive with a steady lateral position and constant speed. Its primary parameter, the standard deviation of lateral position (SDLP), ie, an index of 'weaving', is a stable measure of driving performance with high test-retest reliability. SDLP differences from placebo are dose-dependent, and do not depend on the subject's baseline driving skills (placebo SDLP). It is important that standard operation procedures are applied to conduct the test and analyze the data in order to allow comparisons between studies from different sites.

  7. Are positive and negative reinforcement "different"? Insights from a free-operant differential outcomes effect.

    PubMed

    Magoon, Michael A; Critchfield, Thomas S; Merrill, Dustin; Newland, M Christopher; Schneider, W Joel

    2017-01-01

    Although theoretical discussions typically assume that positive and negative reinforcement differ, the literature contains little unambiguous evidence that they produce differential behavioral effects. To test whether the two types of consequences control behavior differently, we pitted money-gain positive reinforcement and money-loss-avoidance negative reinforcement, scheduled through identically programmed variable-cycle schedules, against each other in concurrent schedules. Contingencies of response-produced feedback, normally different in positive and negative reinforcement, were made symmetrical. Steeper matching slopes were produced compared to a baseline consisting of all positive reinforcement. This free-operant differential outcomes effect supports the notion that that stimulus-presentation positive reinforcement and stimulus-elimination negative reinforcement are functionally "different." However, a control experiment showed that the feedback asymmetry of more traditional positive and negative reinforcement schedules also is sufficient to create a "difference" when the type of consequence is held constant. We offer these findings as a small step in meeting the very large challenge of moving negative reinforcement theory beyond decades of relative quiescence. © 2017 Society for the Experimental Analysis of Behavior.

  8. Mapping of Synaptic-Neuronal Impairment on the Brain Surface through Fluctuation Analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Musha, Toshimitsu; Kurachi, Takayoshi; Suzuki, Naohoro

    2005-08-25

    Increase of demented population year by year is becoming a serious social problem to be solved urgently. The most effective way to block this increase is in its early detection by means of an inexpensive, non-invasive, sensitive, reliable and easy-to-operate diagnosis method. We have developed a method satisfying these requirements by using scalp potential fluctuations. We have collected 21ch EEG and SPECT data of 25 very mild Alzheimer's disease (AD) (MMSE=26{+-}1.8), moderately severe AD (MMSE=15.3{+-}6.4) and age-matched normal controls. As AD progresses, local synaptic-neuronal activity becomes abnormal, either more unstable or more inactive than in normal state. Such abnormality ismore » detected in terms of normalized power variance (NPV) of a scalp potential recorded with a scalp electrode. The z-score is defined by z = ((NPV of a subject) - (mean NPV of normal subjects))/(standard deviation of NPV of normal subjects). Correlation of a measured z-score map with the mean z-score map for AD patients characterizes likelihood to AD, in terms of which AD is discriminated from normal with 75% of true positive and 25% false negative probability. By introducing two thresholds, we have 90% of true positive and 10% of false negative discrimination.« less

  9. 33 CFR 183.220 - Preconditioning for tests.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... motor and controls and for the submerged weight or the battery, respectively. (e) Permanent fuel tanks must be filled with fuel and each external opening into the fuel tank must be sealed. (f) The boat must... be placed in the normal operating position of the motor and controls and the battery in lieu of this...

  10. 46 CFR 56.50-15 - Steam and exhaust piping.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... stress for the material shall not exceed that corresponding to the saturated steam temperature at drum... normal rated operating condition. In both cases, the value of allowable stress shall be selected using a... hot water for heating systems may not exceed 375 °F. (i) Where positive shutoff valves are fitted in...

  11. 47 CFR 80.853 - Radiotelephone station.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... deck above the ship's main deck. (d) The principal operating position of the radiotelephone station must be in the room from which the ship is normally steered while at sea. In installations on cargo ships of 300 gross tons and upwards but less than 500 gross tons on which the keel was laid prior to...

  12. 47 CFR 80.853 - Radiotelephone station.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... deck above the ship's main deck. (d) The principal operating position of the radiotelephone station must be in the room from which the ship is normally steered while at sea. In installations on cargo ships of 300 gross tons and upwards but less than 500 gross tons on which the keel was laid prior to...

  13. 47 CFR 80.853 - Radiotelephone station.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... deck above the ship's main deck. (d) The principal operating position of the radiotelephone station must be in the room from which the ship is normally steered while at sea. In installations on cargo ships of 300 gross tons and upwards but less than 500 gross tons on which the keel was laid prior to...

  14. 47 CFR 80.853 - Radiotelephone station.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... deck above the ship's main deck. (d) The principal operating position of the radiotelephone station must be in the room from which the ship is normally steered while at sea. In installations on cargo ships of 300 gross tons and upwards but less than 500 gross tons on which the keel was laid prior to...

  15. 47 CFR 80.853 - Radiotelephone station.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... deck above the ship's main deck. (d) The principal operating position of the radiotelephone station must be in the room from which the ship is normally steered while at sea. In installations on cargo ships of 300 gross tons and upwards but less than 500 gross tons on which the keel was laid prior to...

  16. Regional Cerebral Blood Flow In Dementia: Receiver-Operating-Characteristic Analysis

    NASA Astrophysics Data System (ADS)

    Zemcov, Alexander; Barclay, Laurie; Sansone, Joseph; Blass, John P.; Metz, Charles E.

    1985-06-01

    The coupling of mentation to regional cerebral blood flow (rCBF) has prompted the application of the Xe-133 inhalation method of measuring rCBF in the differential diagnosis of the two most common dementing diseases, Alzheimer's disease and multi-infarct dementia (MID). In this study receiver-operating-characteristic (ROC) curve analysis was used to assess the effectiveness of a 32 detector Xe-133 inhalation system in discriminating between patients with Alzheimer's disease and normal controls, MID patients and normal controls and between patients with Alzheimer's disease and MID. The populations were clinically evaluated as 1) normal (age 63.1 + 13.1, n=23), 2) Alzheimer's disease (age 72.7 + 7.0, n=82), 3) MID (age 76.4 + 7.6, n=27): The mean flow values for all detectors were lowest for the Alzheimer's disease group, larger for the MID group and largest for the normal controls. The dynamic relationship between the correct identifications (true posi-tives) versus incorrect identifications (false positives) per detector for any 2 pairs of clinical groups varies as the cutoff value of flow is changed over the range of experimental blood flow values. Therefore a quantitative characterization of the "decision" or ROC curve (TP vs FP) for each detector and for each pair of clinical groups provides a measure of the overall diagnostic efficacy of the detector. Detectors directed approximately toward the speech, auditory and association cortices were most effective in disciminatinq between each of the dementia groups and the controls. Frontal detectors were diagnostically inefficient. The Xe-133 inhalation system provided virtually no diagnostic power in discriminating between the two forms of dementia, however. Therefore this imaging technology is most useful when assessing the general diagnostic state of dementia (Alz-heimer's disease and MID) from normal cognitive function.

  17. Hyperestrogenemia and presence of estrogen receptors associated with an epithelial ovarian tumor of low malignant potential.

    PubMed

    Ben-Hur, H; Dgani, R; Insler, V; Lifschitz-Mercer, B; Blickstein, I; Mor, G; Kohen, F; Shani, A; Biran, H

    1996-01-01

    An 80-year-old woman presented with breast congestion, tenderness and pain. Mammography was normal. Circulating estradiol was markedly elevated, while LH and FSH were low. Pelvic examination and imaging revealed an ovarian mass which was extirpated during total abdominal hysterectomy and bilateral salpingo-oophorectomy. Histopathology revealed an ovarian mucinous cystadenocarcinoma of low malignant potential, stage 1. The tumor was positively stained for estrogen receptors. Estradiol levels returned to normal post-operatively, with a corresponding adjustment of LH/FSH. Possible autocrine steroid production is discussed.

  18. Deep Convolutional Neural Networks for Endotracheal Tube Position and X-ray Image Classification: Challenges and Opportunities.

    PubMed

    Lakhani, Paras

    2017-08-01

    The goal of this study is to evaluate the efficacy of deep convolutional neural networks (DCNNs) in differentiating subtle, intermediate, and more obvious image differences in radiography. Three different datasets were created, which included presence/absence of the endotracheal (ET) tube (n = 300), low/normal position of the ET tube (n = 300), and chest/abdominal radiographs (n = 120). The datasets were split into training, validation, and test. Both untrained and pre-trained deep neural networks were employed, including AlexNet and GoogLeNet classifiers, using the Caffe framework. Data augmentation was performed for the presence/absence and low/normal ET tube datasets. Receiver operating characteristic (ROC), area under the curves (AUC), and 95% confidence intervals were calculated. Statistical differences of the AUCs were determined using a non-parametric approach. The pre-trained AlexNet and GoogLeNet classifiers had perfect accuracy (AUC 1.00) in differentiating chest vs. abdominal radiographs, using only 45 training cases. For more difficult datasets, including the presence/absence and low/normal position endotracheal tubes, more training cases, pre-trained networks, and data-augmentation approaches were helpful to increase accuracy. The best-performing network for classifying presence vs. absence of an ET tube was still very accurate with an AUC of 0.99. However, for the most difficult dataset, such as low vs. normal position of the endotracheal tube, DCNNs did not perform as well, but achieved a reasonable AUC of 0.81.

  19. Anxiety and attention: is there an attentional bias for positive emotional stimuli?

    PubMed

    Ruiz-Caballero, J A; Bermúdez, J

    1997-04-01

    Empirical research has shown that anxiety is associated with a systematic bias in the cognitive system. Anxious individuals (clinically anxious patients and normal individuals with high-trait anxiety) are characterized by a pattern of selective processing that favors the encoding of threatening information. Is this attentional bias specific to threat-related information, or does it operate for positive emotional stimuli? The research directly connected with the existence of an attentional bias for threat in anxiety was examined.

  20. A comparison of three methods to evaluate the position of an artificial ear on the deficient side of the face from a three-dimensional surface scan of patients with hemifacial microsomia.

    PubMed

    Coward, Trevor J; Watson, Roger M; Richards, Robin; Scott, Brendan J J

    2012-01-01

    Patients with hemifacial microsomia may have a missing ear on the deficient side of the face. The fabrication of an ear for such individuals usually has been accomplished by directly measuring the ear on the normal side to construct a prosthesis based on these dimensions, and the positioning has been, to a large extent, primarily operator-dependent. The aim of the present study was to compare three methods, developed from the identification of landmarks plotted on three-dimensional surface scans, to evaluate the position of an artificial ear on the deficient side of the face compared with the position of the natural ear on the normally developed side. Laser scans were undertaken of the faces of 14 subjects with hemifacial microsomia. Landmarks on the ear and face on the normal side were identified. Three methods of mirroring the normal ear on the deficient side of the face were investigated, which used either facial landmarks from the orbital area or a zero reference point generated from the intersection of three orthogonal planes on a frame of reference. To assess the methods, landmarks were identified on the ear situated on the normal side as well as on the face. These landmarks yielded paired dimensional measurements that could be compared between the normal and deficient sides. Mean differences and 95% confidence intervals were calculated. It was possible to mirror the normal ear image on to the deficient side of the face using all three methods. Generally only small differences between the dimensional measurements on the normal and deficient sides were observed. However, two-way analysis of variance revealed statistically significant differences between the three methods (P = .005). The method of mirroring using the outer canthi was found to result in the smallest dimensional differences between the anthropometric points on the ear and face between the normally developed and deficient sides. However, the effects of the deformity can result in limitations in relation to achieving a precise alignment of the ear to the facial tissues. This requires further study.

  1. Normalized modes at selected points without normalization

    NASA Astrophysics Data System (ADS)

    Kausel, Eduardo

    2018-04-01

    As every textbook on linear algebra demonstrates, the eigenvectors for the general eigenvalue problem | K - λM | = 0 involving two real, symmetric, positive definite matrices K , M satisfy some well-defined orthogonality conditions. Equally well-known is the fact that those eigenvectors can be normalized so that their modal mass μ =ϕT Mϕ is unity: it suffices to divide each unscaled mode by the square root of the modal mass. Thus, the normalization is the result of an explicit calculation applied to the modes after they were obtained by some means. However, we show herein that the normalized modes are not merely convenient forms of scaling, but that they are actually intrinsic properties of the pair of matrices K , M, that is, the matrices already "know" about normalization even before the modes have been obtained. This means that we can obtain individual components of the normalized modes directly from the eigenvalue problem, and without needing to obtain either all of the modes or for that matter, any one complete mode. These results are achieved by means of the residue theorem of operational calculus, a finding that is rather remarkable inasmuch as the residues themselves do not make use of any orthogonality conditions or normalization in the first place. It appears that this obscure property connecting the general eigenvalue problem of modal analysis with the residue theorem of operational calculus may have been overlooked up until now, but which has in turn interesting theoretical implications.Á

  2. Modeling of human operator dynamics in simple manual control utilizing time series analysis. [tracking (position)

    NASA Technical Reports Server (NTRS)

    Agarwal, G. C.; Osafo-Charles, F.; Oneill, W. D.; Gottlieb, G. L.

    1982-01-01

    Time series analysis is applied to model human operator dynamics in pursuit and compensatory tracking modes. The normalized residual criterion is used as a one-step analytical tool to encompass the processes of identification, estimation, and diagnostic checking. A parameter constraining technique is introduced to develop more reliable models of human operator dynamics. The human operator is adequately modeled by a second order dynamic system both in pursuit and compensatory tracking modes. In comparing the data sampling rates, 100 msec between samples is adequate and is shown to provide better results than 200 msec sampling. The residual power spectrum and eigenvalue analysis show that the human operator is not a generator of periodic characteristics.

  3. The viewpoint-specific failure of modern 3D displays in laparoscopic surgery.

    PubMed

    Sakata, Shinichiro; Grove, Philip M; Hill, Andrew; Watson, Marcus O; Stevenson, Andrew R L

    2016-11-01

    Surgeons conventionally assume the optimal viewing position during 3D laparoscopic surgery and may not be aware of the potential hazards to team members positioned across different suboptimal viewing positions. The first aim of this study was to map the viewing positions within a standard operating theatre where individuals may experience visual ghosting (i.e. double vision images) from crosstalk. The second aim was to characterize the standard viewing positions adopted by instrument nurses and surgical assistants during laparoscopic pelvic surgery and report the associated levels of visual ghosting and discomfort. In experiment 1, 15 participants viewed a laparoscopic 3D display from 176 different viewing positions around the screen. In experiment 2, 12 participants (randomly assigned to four clinically relevant viewing positions) viewed laparoscopic suturing in a simulation laboratory. In both experiments, we measured the intensity of visual ghosting. In experiment 2, participants also completed the Simulator Sickness Questionnaire. We mapped locations within the dimensions of a standard operating theatre at which visual ghosting may result during 3D laparoscopy. Head height relative to the bottom of the image and large horizontal eccentricities away from the surface normal were important contributors to high levels of visual ghosting. Conventional viewing positions adopted by instrument nurses yielded high levels of visual ghosting and severe discomfort. The conventional viewing positions adopted by surgical team members during laparoscopic pelvic operations are suboptimal for viewing 3D laparoscopic displays, and even short periods of viewing can yield high levels of discomfort.

  4. Legionnaires' Disease Bacteria in power plant cooling systems: downtime report. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tyndall, R.L.; Solomon, J.A.; Christensen, S.W.

    1985-04-01

    Legionnaires' Disease Bacteria (Legionella) are a normal part of the aquatic community that, when aerosolized, can be pathogenic to man. The downtime study was designed to determine the degree to which Legionella populations are aerosolized during cleaning and maintenance operations in a closed-cycle steam-electric power plant. Both high-volume and impinger air samples were collected prior to and during downtime operations. Emphasis was placed on sampling inside or adjacent to water boxes, condensers, and cooling towers. Control air samples were taken upwind from the plant site. Water and sludge samples were also collected at various locations. In the laboratory, the concentrationsmore » of Groups A, B, and C Legionella were determined using the direct fluorescent antibody method. All positive air samples, and other selected air samples, were injected into guinea pigs to detect infectious Legionella. Legionella could be detected in only 12 of the 126 air samples collected. These were predominantly Group A Legionella (L. pneumophila, serogroups 1 to 6). All 12 positive samples had been collected in the vicinity of water boxes, condensers, detention ponds, and cooling towers during downtime operations where aerosolization of Legionella populations would be expected. None of the air samples yielded infectious Legionella when injected into guinea pigs. Detection of Legionella in air samples taken during downtime was significantly more likely than detection during normal operating conditions (p <0.01). 13 refs., 4 figs., 10 tabs.« less

  5. Universal Documentation System Handbook. Volume 2. Requirement Formats and Instructions; Program Introduction, Program Requirements Document/Operations Requirements

    DTIC Science & Technology

    1989-08-01

    and the local horizontal plane, measured positive above the horizontal plane. The local horizontal plane is defined as a plane normal to the geocentric ...preparation instructions for Format 1000. LOCATION: Enter the areas or locations that are to be staffed with medical personnel, i.e., Vandenberg AFB

  6. Universal Documentation System Handbook. Volume 2: Program Requirements and Operations Requirements Documents

    DTIC Science & Technology

    1979-11-01

    plane. The local horizontal plane is de- lined as a plane normal to the geocentric position vector. Boxes 11J and UJ are the angles measured east...support the program/mission. BOX 1-9 Follow instructions for Pa«« 1010. BOX 10 LOCATION: Enter the areas or locations that are to be staffed with

  7. 16 CFR 1211.11 - Requirements for photoelectric sensors.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... Requirements for photoelectric sensors. (a) Normal operation test. (1) When installed as described in § 1211.10...) of this section shall consist of a white vertical surface 6 inches (152 mm) high by 12 inches (305 mm... the closed position. See figure 3. EC03OC91.043 (b) Sensitivity test. (1) When installed as described...

  8. 16 CFR 1211.11 - Requirements for photoelectric sensors.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... Requirements for photoelectric sensors. (a) Normal operation test. (1) When installed as described in § 1211.10...) of this section shall consist of a white vertical surface 6 inches (152 mm) high by 12 inches (305 mm... the closed position. See figure 3. EC03OC91.043 (b) Sensitivity test. (1) When installed as described...

  9. 16 CFR 1211.11 - Requirements for photoelectric sensors.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... Requirements for photoelectric sensors. (a) Normal operation test. (1) When installed as described in § 1211.10...) of this section shall consist of a white vertical surface 6 inches (152 mm) high by 12 inches (305 mm... the closed position. See figure 3. EC03OC91.043 (b) Sensitivity test. (1) When installed as described...

  10. 16 CFR § 1211.11 - Requirements for photoelectric sensors.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... § 1211.11 Requirements for photoelectric sensors. (a) Normal operation test. (1) When installed as... in paragraph (a)(1) of this section shall consist of a white vertical surface 6 inches (152 mm) high... plane of the door when in the closed position. See figure 3. EC03OC91.043 (b) Sensitivity test. (1) When...

  11. Investigating the Effects of a Daily Audio-Guided Mindfulness Intervention for Elementary School Students and Teachers

    ERIC Educational Resources Information Center

    Bakosh, Laura S.

    2013-01-01

    Mindfulness practices, used to focus and sustain attention, have been shown to promote school readiness, and to positively impact students' academic success. Yet, incorporating these practices into the normal school day has been difficult due to the curriculum changes and teacher training necessary for implementation and sustainable operation.…

  12. Multiple switch actuator

    DOEpatents

    Beyer, Edward T.

    1976-01-06

    The present invention relates to switches and switch actuating devices to be operated for purposes of arming a bomb or other missile as it is dropped or released from an aircraft. The particular bomb or missile in which this invention is applied is one in which there is a plurality of circuits which are to be armed by the closing of switches upon dropping or releasing of the bomb. The operation of the switches to closed position is normally accomplished by means of a pull-out wire; that is, a wire which is withdrawn from the bomb or missile at the time of release of the bomb, one end of the wire being attached to the aircraft. The conditions to be met are that the arming switches must be positively and surely maintained in open position until the bomb is released and the arming action is effected. The action of the pull-out wire in achieving the arming action must be sure and positive with minimum danger of malfunctioning, jamming or binding.

  13. Integrated head package cable carrier for a nuclear power plant

    DOEpatents

    Meuschke, Robert E.; Trombola, Daniel M.

    1995-01-01

    A cabling arrangement is provided for a nuclear reactor located within a containment. Structure inside the containment is characterized by a wall having a near side surrounding the reactor vessel defining a cavity, an operating deck outside the cavity, a sub-space below the deck and on a far side of the wall spaced from the near side, and an operating area above the deck. The arrangement includes a movable frame supporting a plurality of cables extending through the frame, each connectable at a first end to a head package on the reactor vessel and each having a second end located in the sub-space. The frame is movable, with the cables, between a first position during normal operation of the reactor when the cables are connected to the head package, located outside the sub-space proximate the head package, and a second position during refueling when the cables are disconnected from the head package, located in the sub-space. In a preferred embodiment, the frame straddles the top of the wall in a substantially horizontal orientation in the first position, pivots about an end distal from the head package to a substantially vertically oriented intermediate position, and is guided, while remaining about vertically oriented, along a track in the sub-space to the second position.

  14. Arthroscopic findings of a diagnostic dilemma- hip pathology with normal imaging.

    PubMed

    Buikstra, Joel Glenn; Fary, Camdon; Tran, Phong

    2017-03-21

    Patients with groin, hip and pelvic pain but normal findings on MRI and minimal changes on x-ray can be a diagnostic problem. This paper looks at the arthroscopic findings of patients who have had hip pain and a positive response to an intra-articular anaesthetic but have non-contributory imaging. We hypothesized that standard MRI's were missing significant pathology and if there was a response to intra-articular local anaesthesia, pathology found during arthroscopy was likely. A retrospective review of all hip arthroscopies performed from March 2011 to January 2015 by two orthopaedic surgeons specializing in hip arthroscopy was conducted to identify patients with clinically suspected intra-articular hip pathology despite a normal MRI report and X-ray. Clinical suspicion of intra-articular hip pathology was confirmed with a positive response to a fluoroscopically guided intra-articular injection of local anaesthetic and corticosteroid. Pathologic findings were collated from the standardised operative notes. Fifty-three hip arthroscopies performed in 51 patients met the inclusion criteria from a total of 1348 hip arthroscopies performed over a 46-month period. All but one of the 53 (98%) hips had arthroscopically confirmed pathology. Mean patient age was 32.5 years [15 to 67 years] with 40 (78%) females and 11 (22%) males. 92.5% of the hips (49/53) were FADIR (flexion, adduction and internal rotation) positive on clinical examination, giving this test a positive predictive value of 98% (95% CI: 89.31 to 99.67%) for intra-articular pathology. In patients with a normal MRI without contrast and a positive response (relief of pain) to an intra-articular injection that failed conservative management, there is a 98% chance of intra-articular hip pathology being discovered on hip arthroscopy.

  15. The spectral theorem for quaternionic unbounded normal operators based on the S-spectrum

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Alpay, Daniel, E-mail: dany@math.bgu.ac.il; Kimsey, David P., E-mail: dpkimsey@gmail.com; Colombo, Fabrizio, E-mail: fabrizio.colombo@polimi.it

    In this paper we prove the spectral theorem for quaternionic unbounded normal operators using the notion of S-spectrum. The proof technique consists of first establishing a spectral theorem for quaternionic bounded normal operators and then using a transformation which maps a quaternionic unbounded normal operator to a quaternionic bounded normal operator. With this paper we complete the foundation of spectral analysis of quaternionic operators. The S-spectrum has been introduced to define the quaternionic functional calculus but it turns out to be the correct object also for the spectral theorem for quaternionic normal operators. The lack of a suitable notion ofmore » spectrum was a major obstruction to fully understand the spectral theorem for quaternionic normal operators. A prime motivation for studying the spectral theorem for quaternionic unbounded normal operators is given by the subclass of unbounded anti-self adjoint quaternionic operators which play a crucial role in the quaternionic quantum mechanics.« less

  16. 78 FR 39591 - Drawbridge Operation Regulation; Lake Washington Ship Canal at Seattle, WA

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-07-02

    ...The Coast Guard has issued a temporary deviation from the operating schedule that governs three Seattle Department of Transportation (SDOT) bridges: The Ballard Bridge, mile 1.1, the Fremont Bridge, mile 2.6, and the University Bridge, mile 4.3, all crossing the Lake Washington Ship Canal at Seattle, WA. The deviation is necessary to accommodate heavier than normal roadway traffic associated with a fireworks display over Lake Union. This deviation allows the bridges to remain in the closed position immediately prior to until immediately after the fireworks display.

  17. Assembly for facilitating inservice inspection of a reactor coolant pump rotor

    DOEpatents

    Veronesi, Luciano

    1990-01-01

    A reactor coolant pump has an outer casing with an internal cavity holding a coolant and a rotor rotatably mounted in the cavity within the coolant. An assembly for permitting inservice inspection of the pump rotor without first draining the coolant from the casing cavity is attached to an end of the pump. A cylindrical bore is defined through the casing in axial alignment with an end of pump rotor and opening into the internal cavity. An extension attached on the rotor end and rotatable therewith has a cylindrical coupler member extending into the bore. An outer end of the coupler member has an element configured to receive a tool for performance of inservice rotor inspection. A hollow cylindrical member is disposed in the bore and surrounds the coupler member. The cylindrical member is slidably movable relative to the coupler member along the bore between a retracted position wherein the cylindrical member is stored for normal pump operation and an extended position wherein the cylindrical member is extended for permitting inservice rotor inspection. A cover member is detachably and sealably attached to the casing across the bore for closing the bore and retaining the cylindrical member at its retracted position for normal pump operation. Upon detachment of the cover member, the cylindrical member can be extended to permit inservice rotor inspection.

  18. Universal Documentation System Handbook. Volume 2. Requirement Formats and Instructions, Program Introduction, Program Requirements Document/Operations Requirements.

    DTIC Science & Technology

    1989-08-01

    horizontal plane is defined as a plane normal to the geocentric position vector. Inertial Azimuth Heading Angle entries are the angles measured east of north...0CATICN: Enter the areas or locations that are to be staffed with redical perscnel, i.e., Vandenberg AFB Hospital, PMIC; or offshore boats, etc. NUMB

  19. 47 CFR 80.1091 - Ship radio equipment-Sea areas A1, A2, and A3.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... the transmission of ship-to-shore distress alerts by a radio service operating either: (i) Through the..., the position from which the ship is normally navigated); or (ii) On HF using DSC: or (iii) Through the...); and (3) Means of initiating the transmission of ship-to-shore distress alerts by a radio-communication...

  20. 47 CFR 80.1091 - Ship radio equipment-Sea areas A1, A2, and A3.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... the transmission of ship-to-shore distress alerts by a radio service operating either: (i) Through the..., the position from which the ship is normally navigated); or (ii) On HF using DSC: or (iii) Through the...); and (3) Means of initiating the transmission of ship-to-shore distress alerts by a radio-communication...

  1. 47 CFR 80.1091 - Ship radio equipment-Sea areas A1, A2, and A3.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... the transmission of ship-to-shore distress alerts by a radio service operating either: (i) Through the..., the position from which the ship is normally navigated); or (ii) On HF using DSC: or (iii) Through the...); and (3) Means of initiating the transmission of ship-to-shore distress alerts by a radio-communication...

  2. 77 FR 5302 - Ford Motor Company, Receipt of Petition for Decision of Inconsequential Noncompliance

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-02

    ... plane of the steering wheel hub; or for a turn signal control that is operated in a plane essentially parallel to the face plane of the steering wheel in its normal driving position and which is located on the... face plane of the steering wheel hub, the identifier must meet Table 2 requirements for the horn...

  3. EMERGENCY SHUTDOWN FOR NUCLEAR REACTORS

    DOEpatents

    Paget, J.A.; Koutz, S.L.; Stone, R.S.; Stewart, H.B.

    1963-12-24

    An emergency shutdown or scram apparatus for use in a nuclear reactor that includes a neutron absorber suspended from a temperature responsive substance that is selected to fail at a preselected temperature in excess of the normal reactor operating temperature, whereby the neutron absorber is released and allowed to fall under gravity to a preselected position within the reactor core is presented. (AEC)

  4. A data acquisition system for coincidence imaging using a conventional dual head gamma camera

    NASA Astrophysics Data System (ADS)

    Lewellen, T. K.; Miyaoka, R. S.; Jansen, F.; Kaplan, M. S.

    1997-06-01

    A low cost data acquisition system (DAS) was developed to acquire coincidence data from an unmodified General Electric Maxxus dual head scintillation camera. A high impedance pick-off circuit provides position and energy signals to the DAS without interfering with normal camera operation. The signals are pulse-clipped to reduce pileup effects. Coincidence is determined with fast timing signals derived from constant fraction discriminators. A charge-integrating FERA 16 channel ADC feeds position and energy data to two CAMAC FERA memories operated as ping-pong buffers. A Macintosh PowerPC running Labview controls the system and reads the CAMAC memories. A CAMAC 12-channel scaler records singles and coincidence rate data. The system dead-time is approximately 10% at a coincidence rate of 4.0 kHz.

  5. [EFFECTIVENESS COMPARISON OF PROXIMAL FEMORAL NAIL ANTI-ROTATION IN SUPINE "SCISSORS" POSITION AND IN LITHOTOMY POSITION TO TREAT FEMORAL INTERTROCHANTERIC FRACTURES OF OLD PATIENTS].

    PubMed

    Du, Shihao; Yin, Fei; Wei, Xuming; Song, Sheng; Gu, Sanjun; Sun, Zhenzhong; Rui, Yongjun

    2016-02-01

    To compare the effectiveness of proximal femoral nail anti-rotation (PFNA) between in the supine "scissors" position and in the lithotomy position for treating femoral intertrochanteric fractures of old patients. A retrospective study was performed on 58 patients with femoral intertrochanteric fractures treated with PFNA between January 2013 and January 2015. Fracture was treated with PFNA in the lithotomy position in 28 cases (group A) and in the supine "scissors" position in 30 cases (group B). There was no significant difference in gender, age, side, cause of injury, fracture type, and interval from injury to operation between 2 groups (P>0.05). The incision length, operation time, perspective times, intraoperative blood loss, complications, and fracture healing time were recorded; Harris hip score was used to access the effectiveness. The wound healed by first intention without infection, pressure sores, deep vein thrombosis of lower extremity, and other complications. There was no significant difference in incision length between 2 groups (t=1.313, P=0.212). Group B was significantly better than group A in operation time, perspective times, and intraoperative blood loss (P<0.05). All patients were followed up 10-31 months (mean, 15.3 months). Stretch injury at normal side and perineal discomfort occurred in 1 case and 5 cases of group A respectively, and no nonunion and other complications was observed in the other patients. There was no significant difference in fracture healing time and Harris hip score at last follow-up between 2 groups (P>0.05). PFNA in the supine "scissors" position has exact effectiveness and advantages of shorter operation time, less intraoperative blood loss, less perspective times, and fewer complications.

  6. Effect of septoplasty and per-operative antibiotic prophylaxis on nasal flora.

    PubMed

    Karaman, E; Alimoglu, Y; Aygun, G; Kilic, E; Yagiz, C

    2012-01-01

    Septoplasty is one of the most commonly performed procedures in otolaryngology practice. Prophylactic use of antibiotics is controversial. Disruption of nasal flora may predispose individuals to infection. We investigated the effect of antibiotic prophylaxis and septoplasty on nasal flora. We included 115 consecutive patients who underwent septoplasty because of symptomatic nasal septal deviation. Patients were divided into study and control groups. Study patients received prophylactic parenteral sodium cefazoline twice a day beginning intra-operatively and while the nasal packing remained in the nose for 48 h, and expandable polyvinyl acetate (Merocel) packing covered with antibiotic ointment containing 0.2% nitrofurazone was inserted into each nostril at the end of the operation. Control patients received neither parenteral antibiotic prophylaxis nor antibiotic ointment around the Merocel packs. Both groups received oral prophylactic cefuroxime axetil for 5 d after nasal packing was removed. Nasal flora was determined pre-operatively, post-operatively when nasal packing was removed, and 3 mo after surgery. Study patients were compared to control patients at pack removal and 1 mo after surgery The effect of antibiotic use in septoplasty on nasal flora was as follows: Increased isolation rate of gram-positive rods (p = 0.007), decreased methicillin-sensitive coagulase-negative staphylococci (p = 0.002). Pre-operative and post-operative culture results at 3 mo were compared. The effect of septoplasty on nasal flora was as follows: Decreased coagulase-negative staphylococci (p = 0.05), decreased Klebsiella (p < 0.001), decreased gram-positive rods (p < 0.001), increased methicillin-sensitive Staphylococcus aureus (p < 0.001). Septoplasty increases S. aureus colonization and decreases normal flora. Antibiotics do not protect against S. aureus colonization and contribute to a decrease in normal flora. Antibiotics do not seem to confer benefit in terms of flora changes. Studies investigating flora changes with a longer follow-up should be conducted.

  7. Using Four-Layer Sculpted Rib Cartilage Framework to Increase Transverse Height of the Reconstructive Ear in One Operative Stage for Microtia Patients.

    PubMed

    Wan, Rui; Pang, Xingyuan; Ren, Jun

    2018-02-01

    This case study improves an operative method of ear reconstruction for microtia patients by using a four-layer rib cartilage framework to increase transverse height of the reconstructive ear to a natural level in one operative stage. The procedures of ear reconstruction were conducted from February 2014 to May 2016. The ear framework used in the procedures was fabricated from autologous rib cartilage into a four-layer spliced sculpture. Totally 23 patients with unilateral microtia were willing to be enrolled in this study. After the operation, 23 patients achieved 2.3-2.8 cm transverse height of reconstructed ears, which was basically the same as the normal side. Both patients and their families felt satisfied with the results. Follow-up was performed at 6-16 months after the procedures. Only one case showed significantly lowered transverse height of the reconstructed ear, compared to the normal one. It was due to the sleeping position of the patient (10-year-old boy), which put the reconstructed ear under pressure and reduced the transverse height of the ear. The method of four-layer sculpted autologous rib cartilage ear reconstruction has good clinical effect. It can provide a reconstructed ear that reaches normal transverse height and avoids a third operation to increase the transverse height by rib cartilage transplantation. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .

  8. 49 CFR 192.605 - Procedural manual for operations, maintenance, and emergencies.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... operations and maintenance activities are conducted. (b) Maintenance and normal operations. The manual... personnel to determine the effectiveness, and adequacy of the procedures used in normal operation and... or flow rate outside normal operating limits; (iii) Loss of communications; (iv) Operation of any...

  9. Virtual 3D planning of tracheostomy placement and clinical applicability of 3D cannula design: a three-step study.

    PubMed

    de Kleijn, Bertram J; Kraeima, Joep; Wachters, Jasper E; van der Laan, Bernard F A M; Wedman, Jan; Witjes, M J H; Halmos, Gyorgy B

    2018-02-01

    We aimed to investigate the potential of 3D virtual planning of tracheostomy tube placement and 3D cannula design to prevent tracheostomy complications due to inadequate cannula position. 3D models of commercially available cannula were positioned in 3D models of the airway. In study (1), a cohort that underwent tracheostomy between 2013 and 2015 was selected (n = 26). The cannula was virtually placed in the airway in the pre-operative CT scan and its position was compared to the cannula position on post-operative CT scans. In study (2), a cohort with neuromuscular disease (n = 14) was analyzed. Virtual cannula placing was performed in CT scans and tested if problems could be anticipated. Finally (3), for a patient with Duchenne muscular dystrophy and complications of conventional tracheostomy cannula, a patient-specific cannula was 3D designed, fabricated, and placed. (1) The 3D planned and post-operative tracheostomy position differed significantly. (2) Three groups of patients were identified: (A) normal anatomy; (B) abnormal anatomy, commercially available cannula fits; and (C) abnormal anatomy, custom-made cannula, may be necessary. (3) The position of the custom-designed cannula was optimal and the trachea healed. Virtual planning of the tracheostomy did not correlate with actual cannula position. Identifying patients with abnormal airway anatomy in whom commercially available cannula cannot be optimally positioned is advantageous. Patient-specific cannula design based on 3D virtualization of the airway was beneficial in a patient with abnormal airway anatomy.

  10. Dual capacity reciprocating compressor

    DOEpatents

    Wolfe, Robert W.

    1984-01-01

    A multi-cylinder compressor 10 particularly useful in connection with northern climate heat pumps and in which different capacities are available in accordance with reversing motor 16 rotation is provided with an eccentric cam 38 on a crank pin 34 under a fraction of the connecting rods, and arranged for rotation upon the crank pin between opposite positions 180.degree. apart so that with cam rotation on the crank pin such that the crank throw is at its normal maximum value all pistons pump at full capacity, and with rotation of the crank shaft in the opposite direction the cam moves to a circumferential position on the crank pin such that the overall crank throw is zero. Pistons 24 whose connecting rods 30 ride on a crank pin 36 without a cam pump their normal rate with either crank rotational direction. Thus a small clearance volume is provided for any piston that moves when in either capacity mode of operation.

  11. Dual capacity reciprocating compressor

    DOEpatents

    Wolfe, R.W.

    1984-10-30

    A multi-cylinder compressor particularly useful in connection with northern climate heat pumps and in which different capacities are available in accordance with reversing motor rotation is provided with an eccentric cam on a crank pin under a fraction of the connecting rods, and arranged for rotation upon the crank pin between opposite positions 180[degree] apart so that with cam rotation on the crank pin such that the crank throw is at its normal maximum value all pistons pump at full capacity, and with rotation of the crank shaft in the opposite direction the cam moves to a circumferential position on the crank pin such that the overall crank throw is zero. Pistons whose connecting rods ride on a crank pin without a cam pump their normal rate with either crank rotational direction. Thus a small clearance volume is provided for any piston that moves when in either capacity mode of operation. 6 figs.

  12. Reliability of Waveform Analysis as an Adjunct to Loss of Resistance for Thoracic Epidural Blocks.

    PubMed

    Leurcharusmee, Prangmalee; Arnuntasupakul, Vanlapa; Chora De La Garza, Daniel; Vijitpavan, Amorn; Ah-Kye, Sonia; Saelao, Abhidej; Tiyaprasertkul, Worakamol; Finlayson, Roderick J; Tran, De Q H

    2015-01-01

    The epidural space is most commonly identified with loss of resistance (LOR). Although sensitive, LOR lacks specificity, as cysts in interspinous ligaments, gaps in ligamentum flavum, paravertebral muscles, thoracic paravertebral spaces, and intermuscular planes can yield nonepidural LOR. Epidural waveform analysis (EWA) provides a simple confirmatory adjunct for LOR. When the needle is correctly positioned inside the epidural space, measurement of the pressure at its tip results in a pulsatile waveform. In this observational study, we set out to assess the sensitivity, specificity, as well as positive and negative predictive values of EWA for thoracic epidural blocks. We enrolled a convenience sample of 160 patients undergoing thoracic epidural blocks for thoracic surgery, abdominal surgery, or rib fractures. The choice of patient position (sitting or lateral decubitus), approach (midline or paramedian), and LOR medium (air or normal saline) was left to the operator (attending anesthesiologist, fellow, or resident). After obtaining a satisfactory LOR, the operator injected 5 mL of normal saline through the epidural needle. A sterile tubing, connected to a pressure transducer, was attached to the needle to measure the pressure at the needle tip. A 4-mL bolus of lidocaine 2% with epinephrine 5 μg/mL was then administered and, after 10 minutes, the patient was assessed for sensory blockade to ice. The failure rate (incorrect identification of the epidural space with LOR) was 23.1%. Of these 37 failed epidural blocks, 27 provided no sensory anesthesia at 10 minutes. In 10 subjects, the operator was unable to thread the catheter through the needle. When compared with the ice test, the sensitivity, specificity, and positive and negative predictive values of EWA were 91.1%, 83.8%, 94.9%, and 73.8%, respectively. Epidural waveform analysis (with pressure transduction through the needle) provides a simple adjunct to LOR for thoracic epidural blocks. Although its use was devoid of complications, further confirmatory studies are required before its routine implementation in clinical practice.

  13. [Dropped head syndrome as first manifestation of primary hyperparathyroid myopathy].

    PubMed

    Ota, Kiyobumi; Koseki, Sayo; Ikegami, Kenji; Onishi, Iichiroh; Tomimitsu, Hiyoryuki; Shintani, Shuzo

    2018-03-28

    75 years old woman presented with 6-month history of progressive dropped head syndrome. Neurological examination revealed moderate weakness of flexor and extensor of neck and mild weakness of proximal appendicular muscles with normal deep tendon reflexes. The needle electromyography showed short duration and low amplitude motor unit potential. No fibrillation potentials or positive sharp waves were seen. Biopsy of deltoid muscle was normal. Laboratory studies showed elevated levels of serum calcium (11.8 mg/dl, upper limit of normal 10.1) and intact parathyroid hormone (104 pg/ml, upper limit of normal 65), and decreased level of serum phosphorus (2.3 mg/dl, lower limit of normal 2.7). Ultrasonography and enhanced computed tomography revealed a parathyroid tumor. The tumor was removed surgically. Pathological examination proved tumor to be parathyroid adenoma. Dropped head and weakness of muscles were dramatically improved within a week after the operation. Although hyperparathyroidism is a rare cause of dropped head syndrome, neurologists must recognize hyperparathyroidism as a treatable cause of dropped head syndrome.

  14. Operational Performance Risk Assessment in Support of A Supervisory Control System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Denning, Richard S.; Muhlheim, Michael David; Cetiner, Sacit M.

    Supervisory control system (SCS) is developed for multi-unit advanced small modular reactors to minimize human interventions in both normal and abnormal operations. In SCS, control action decisions made based on probabilistic risk assessment approach via Event Trees/Fault Trees. Although traditional PRA tools are implemented, their scope is extended to normal operations and application is reversed; success of non-safety related system instead failure of safety systems this extended PRA approach called as operational performance risk assessment (OPRA). OPRA helps to identify success paths, combination of control actions for transients and to quantify these success paths to provide possible actions without activatingmore » plant protection system. In this paper, a case study of the OPRA in supervisory control system is demonstrated within the context of the ALMR PRISM design, specifically power conversion system. The scenario investigated involved a condition that the feed water control valve is observed to be drifting to the closed position. Alternative plant configurations were identified via OPRA that would allow the plant to continue to operate at full or reduced power. Dynamic analyses were performed with a thermal-hydraulic model of the ALMR PRISM system using Modelica to evaluate remained safety margins. Successful recovery paths for the selected scenario are identified and quantified via SCS.« less

  15. Ternary compound electrode for lithium cells

    DOEpatents

    Raistrick, I.D.; Godshall, N.A.; Huggins, R.A.

    1980-07-30

    Lithium-based cells are promising for applications such as electric vehicles and load-leveling for power plants since lithium is very electropositive and of light weight. One type of lithium-based cell utilizes a molten salt electrolyte and normally is operated in the temperature range of about 350 to 500/sup 0/C. Such high temperature operation accelerates corrosion problems. The present invention provides an electrochemical cell in which lithium is the electroactive species. The cell has a positive electrode which includes a ternary compound generally represented as Li-M-O, wherein M is a transition metal. Corrosion of the inventive cell is considerably reduced.

  16. Ternary compound electrode for lithium cells

    DOEpatents

    Raistrick, Ian D.; Godshall, Ned A.; Huggins, Robert A.

    1982-01-01

    Lithium-based cells are promising for applications such as electric vehicles and load-leveling for power plants since lithium is very electropositive and of light weight. One type of lithium-based cell utilizes a molten salt electrolyte and normally is operated in the temperature range of about 350.degree.-500.degree. C. Such high temperature operation accelerates corrosion problems. The present invention provides an electrochemical cell in which lithium is the electroactive species. The cell has a positive electrode which includes a ternary compound generally represented as Li-M-O, wherein M is a transition metal. Corrosion of the inventive cell is considerably reduced.

  17. Internal Flow and Burning Characteristics of 16-inch Ram Jet Operating in a Free Jet at Mach Numbers of 1.35 and 1.73

    NASA Technical Reports Server (NTRS)

    Perchonok, Eugene; Farley, John M

    1951-01-01

    The effects of mass-flow ratio on the additive drag and normal-shock position of a single oblique-shock diffuser are presented. Also evaluated is the variation with operating condition of the velocity distribution at the combustion-chamber inlet. A comparison with connected-pipe data is included. Burner performance with a corrugated gutter-grid flame holder is discussed. It is shown that the total-pressure drop across the combustion chamber can be predicted with reasonable accuracy from the computed flame holder and combustion momentum pressure losses.

  18. LGALS4, CEACAM6, TSPAN8, and COL1A2: Blood Markers for Colorectal Cancer-Validation in a Cohort of Subjects With Positive Fecal Immunochemical Test Result.

    PubMed

    Rodia, Maria Teresa; Solmi, Rossella; Pasini, Francesco; Nardi, Elena; Mattei, Gabriella; Ugolini, Giampaolo; Ricciardiello, Luigi; Strippoli, Pierluigi; Miglio, Rossella; Lauriola, Mattia

    2018-06-01

    A noninvasive blood test for the early detection of colorectal cancer (CRC) is highly required. We evaluated a panel of 4 mRNAs as putative markers of CRC. We tested LGALS4, CEACAM6, TSPAN8, and COL1A2, referred to as the CELTiC panel, using quantitative reverse transcription polymerase chain reaction, on subjects with positive fecal immunochemical test (FIT) results and undergoing colonoscopy. Using a nonparametric test and multinomial logistic model, FIT-positive subjects were compared with CRC patients and healthy individuals. All the genes of the CELTiC panel displayed statistically significant differences between the healthy subjects (n = 67), both low-risk (n = 36) and high-risk/CRC (n = 92) subjects, and those in the negative-colonoscopy, FIT-positive group (n = 36). The multinomial logistic model revealed LGALS4 was the most powerful marker discriminating the 4 groups. When assessing the diagnostic values by analysis of the areas under the receiver operating characteristic curves (AUCs), the CELTiC panel reached an AUC of 0.91 (sensitivity, 79%; specificity, 94%) comparing normal subjects to low-risk subjects, and 0.88 (sensitivity, 75%; specificity, 87%) comparing normal and high-risk/CRC subjects. The comparison between the normal subjects and the negative-colonoscopy, FIT-positive group revealed an AUC of 0.93 (sensitivity, 82%; specificity, 97%). The CELTiC panel could represent a useful tool for discriminating subjects with positive FIT findings and for the early detection of precancerous adenomatous lesions and CRC. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. Time Course of Substance P Expression in Dorsal Root Ganglia Following Complete Spinal Nerve Transection

    PubMed Central

    Weissner, Wendy; Winterson, Barbara J.; Stuart-Tilley, Alan; Devor, Marshall; Bove, Geoffrey M.

    2008-01-01

    Recent evidence suggests that substance P (SP) is upregulated in primary sensory neurons following axotomy, and that this change occurs in larger neurons that do not usually produce SP. If so, this upregulation may allow normally neighboring, uninjured, and non-nociceptive dorsal root ganglion (DRG) neurons to become effective in activating pain pathways. Using immunohistochemistry, we performed a unilateral L5 spinal nerve transection upon male Wistar rats, and measured SP expression in ipsilateral L4 and L5 DRGs and contralateral L5 DRGs, at 1 to 14 days postoperatively (dpo), and in control and sham operated rats. In normal and sham operated DRGs, SP was detectable almost exclusively in small neurons (≤ 800 μm2). Following surgery, the mean size of SP-positive neurons from the axotomized L5 ganglia was greater at 2, 4, 7 and 14 dpo. Among large neurons (> 800 μm2) from the axotomized L5, the percentage of SP-positive neurons increased at 2, 4, 7, and 14 dpo. Among small neurons from the axotomized L5, the percentage of SP-positive neurons was increased at 1 and 3 dpo, but was decreased at 7 and 14 dpo. Thus, SP expression is affected by axonal damage, and the time course of the expression is different between large and small DRG neurons. These data support a role of SP-producing, large DRG neurons in persistent sensory changes due to nerve injury. PMID:16680762

  20. Inertial sensing microelectromechanical (MEM) safe-arm device

    DOEpatents

    Roesler, Alexander W [Tijeras, NM; Wooden, Susan M [Sandia Park, NM

    2009-05-12

    Microelectromechanical (MEM) safe-arm devices comprise a substrate upon which a sense mass, that can contain an energetic material, is constrained to move along a pathway defined by a track disposed on the surface of the substrate. The pathway has a first end comprising a "safe" position and a second end comprising an "armed" position, whereat the second end the sense mass can be aligned proximal to energetic materials comprising the explosive train, within an explosive component. The sense mass can be confined in the safe position by a first latch, operable to release the sense mass by an acceleration acting in a direction substantially normal to the surface of the substrate. A second acceleration, acting in a direction substantially parallel to the surface of the substrate, can cause the sense mass to traverse the pathway from the safe position to the armed position.

  1. An Exploratory Study of Gambling Operators' Use of Social Media and the Latent Messages Conveyed.

    PubMed

    Gainsbury, Sally M; Delfabbro, Paul; King, Daniel L; Hing, Nerilee

    2016-03-01

    Advertisements for gambling products have historically been restricted due to their potential to normalize gambling and contribute to excessive gambling behaviours among vulnerable populations. However, social media enables gambling operators to promote products and brands with fewer constraints than in traditional forms of media. This study investigated how social media is used by gambling operators to promote gambling activities including an analysis of the latent messages that are conveyed. A representative sample of major land-based and online gambling venues and operators, including casinos, clubs, hotels, lottery and wagering operators (n = 101), was obtained. Websites and social media profiles of gambling operators were audited to investigate the types of social media used, content of promotions, and prevalence of responsible gambling messaging. The results showed that Facebook and Twitter were the dominant platforms used, most commonly by casinos and online wagering operators. A key finding was that online gambling operators included gambling content in conjunction with related news and events, as well as unrelated content, as way of normalizing gambling within a broader social context. Unlike land-based gambling promotions, responsible gambling information tended not to feature in operators' posts and profiles. The key messages propagated in social media gambling promotions were positively framed, and tended to encourage gambling using a range of cross-promotional tactics to emphasize the winning aspect of gambling. The implications of freely accessible and pervasive gambling promotions via social media are discussed with respect to the general community as well as vulnerable populations.

  2. Vibrations of a Marine Propeller Operating in a Nonuniform Inflow.

    DTIC Science & Technology

    1980-04-01

    Expanded Blade Midsurface ......... ........................ ... 73 16 - Calculated Normalized Propeller RMS Vibration Velocity as a Function of...averaged over the blade midsurface ), rather thaft the maximum velocities near the blade tip. Then, for the two test propellers, the rms nonuniform inflow...time- averaged midsurface of the blade, then the instantaneous position S of the vibrating midsurface is _S (ric)+ qct S(r,c,t) = (rc) + q(t) i(rc

  3. In vitro genotoxicity of exhaust emissions of diesel and gasoline engine vehicles operated on a unified driving cycle.

    PubMed

    Liu, Yu-Qing; Keane, Michael; Ensell, Mang; Miller, William; Kashon, Michael; Ong, Tong-man; Mauderly, Joe; Lawson, Doug; Gautam, Mridul; Zielinska, Barbara; Whitney, Kevin; Eberhardt, James; Wallace, William

    2005-01-01

    Acetone extracts of engine exhaust particulate matter (PM) and of vapor-phase semi-volatile organic compounds (SVOCs) collected from a set of 1998-2000 model year normal emitter diesel engine automobile or light trucks and from a set of 1982-1996 normal emitter gasoline engine automobiles or light trucks operated on the California Unified Driving Cycle at 22 [degree]C were assayed for in vitro genotoxic activities. Gasoline and diesel PM were comparably positive mutagens for Salmonella typhimurium strains YG1024 and YG1029 on a mass of PM extract basis with diesel higher on a mileage basis; gasoline SVOC was more active than diesel on an extracted-mass basis, with diesel SVOC more active on a mileage basis. For chromosomal damage indicated by micronucleus induction in Chinese hamster lung fibroblasts (V79 cells), diesel PM expressed about one-tenth that of gasoline PM on a mass of extract basis, but was comparably active on a mileage basis; diesel SVOC was inactive. For DNA damage in V79 cells indicated by the single cell gel electrophoresis (SCGE) assay, gasoline PM was positive while diesel PM was active at the higher doses; gasoline SVOC was active with toxicity preventing measurement at high doses, while diesel SVOC was inactive at all but the highest dose.

  4. Ballistic Transport for Limit-Periodic Jacobi Matrices with Applications to Quantum Many-Body Problems

    NASA Astrophysics Data System (ADS)

    Fillman, Jake

    2017-03-01

    We study Jacobi matrices that are uniformly approximated by periodic operators. We show that if the rate of approximation is sufficiently rapid, then the associated quantum dynamics are ballistic in a rather strong sense; namely, the (normalized) Heisenberg evolution of the position operator converges strongly to a self-adjoint operator that is injective on the space of absolutely summable sequences. In particular, this means that all transport exponents corresponding to well-localized initial states are equal to one. Our result may be applied to a class of quantum many-body problems. Specifically, we establish a lower bound on the Lieb-Robinson velocity for an isotropic XY spin chain on the integers with limit-periodic couplings.

  5. Intensity modulated operating mode of the rotating gamma system.

    PubMed

    Sengupta, Bishwambhar; Gulyas, Laszlo; Medlin, Donald; Koroknai, Tibor; Takacs, David; Filep, Gyorgy; Panko, Peter; Godo, Bence; Hollo, Tamas; Zheng, Xiao Ran; Fedorcsak, Imre; Dobai, Jozsef; Bognar, Laszlo; Takacs, Endre

    2018-05-01

    The purpose of this work was to explore two novel operation modalities of the rotating gamma systems (RGS) that could expand its clinical application to lesions in close proximity to critical organs at risk (OAR). The approach taken in this study consists of two components. First, a Geant4-based Monte Carlo (MC) simulation toolkit is used to model the dosimetric properties of the RGS Vertex 360™ for the normal, intensity modulated radiosurgery (IMRS), and speed modulated radiosurgery (SMRS) operation modalities. Second, the RGS Vertex 360™ at the Rotating Gamma Institute in Debrecen, Hungary is used to collect experimental data for the normal and IMRS operation modes. An ion chamber is used to record measurements of the absolute dose. The dose profiles are measured using Gafchromic EBT3 films positioned within a spherical water equivalent phantom. A strong dosimetric agreement between the measured and simulated dose profiles and penumbra was found for both the normal and IMRS operation modes for all collimator sizes (4, 8, 14, and 18 mm diameter). The simulated falloff and maximum dose regions agree better with the experimental results for the 4 and 8 mm diameter collimators. Although the falloff regions align well in the 14 and 18 mm collimators, the maximum dose regions have a larger difference. For the IMRS operation mode, the simulated and experimental dose distributions are ellipsoidal, where the short axis aligns with the blocked angles. Similarly, the simulated dose distributions for the SMRS operation mode also adopt an ellipsoidal shape, where the short axis aligns with the angles where the orbital speed is highest. For both modalities, the dose distribution is highly constrained with a sharper penumbra along the short axes. Dose modulation of the RGS can be achieved with the IMRS and SMRS modes. By providing a highly constrained dose distribution with a sharp penumbra, both modes could be clinically applicable for the treatment of lesions in close proximity to critical OARs. © 2018 American Association of Physicists in Medicine.

  6. 40 CFR 68.52 - Operating procedures.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ...) Initial startup; (2) Normal operations; (3) Temporary operations; (4) Emergency shutdown and operations; (5) Normal shutdown; (6) Startup following a normal or emergency shutdown or a major change that... are updated, if necessary, whenever a major change occurs and prior to startup of the changed process. ...

  7. 40 CFR 68.52 - Operating procedures.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ...) Initial startup; (2) Normal operations; (3) Temporary operations; (4) Emergency shutdown and operations; (5) Normal shutdown; (6) Startup following a normal or emergency shutdown or a major change that... are updated, if necessary, whenever a major change occurs and prior to startup of the changed process. ...

  8. 40 CFR 68.52 - Operating procedures.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ...) Initial startup; (2) Normal operations; (3) Temporary operations; (4) Emergency shutdown and operations; (5) Normal shutdown; (6) Startup following a normal or emergency shutdown or a major change that... are updated, if necessary, whenever a major change occurs and prior to startup of the changed process. ...

  9. 40 CFR 68.52 - Operating procedures.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...) Initial startup; (2) Normal operations; (3) Temporary operations; (4) Emergency shutdown and operations; (5) Normal shutdown; (6) Startup following a normal or emergency shutdown or a major change that... are updated, if necessary, whenever a major change occurs and prior to startup of the changed process. ...

  10. What is a Good Looking Penis? How Women Rate the Penile Appearance of Men with Surgically Corrected Hypospadias.

    PubMed

    Ruppen-Greeff, Norma Katharina; Weber, Daniel M; Gobet, Rita; Landolt, Markus A

    2015-08-01

    Some men with corrected hypospadias perceive their penile appearance to be abnormal, although health professionals consider these results satisfactory. The aim of this study was to investigate how relevant women consider single aspects of penile appearance to be. Moreover, we studied whether women perceive hypospadias-affected surgically repaired genitals (HASRGs) to be as normal-looking as circumcised genitals and identified the most relevant predictors that influence whether a penis is perceived as normal. In this cross-sectional study, 105 women in different age groups (age range: 16-20, 25-30, and 40-45 years) completed a standardized questionnaire. Participants had to rate the importance of eight penile aspects and to indicate how normal they found the appearance of standardized photos of 10 HASRGs and of 10 circumcised genitals. Furthermore, they were asked about demographic characteristics and their sexuality. Results showed that women considered the position and shape of the meatus as the least important penile aspect. Furthermore, results showed that HASRGs with distal hypospadias were perceived to be as normal-looking as circumcised genitals, whereas genitals with more proximal hypospadias were perceived as significantly less normal. However, the difference need not be considered clinically relevant, as the effect size was small. Observer-related predictors of a more positive perception of HASRGs were higher age, higher sexual interest, and perceiving the general cosmetic penile appearance as more important and penile length as less important. Overall, women were found to consider the "position and shape of the meatus" as the least important penile aspect. These findings may stimulate reflections regarding the relevance of surgical correction of the meatus in minor forms of hypospadias. In addition, this study indicates that women perceived genitals of men with distal operated hypospadias (which represents the majority of hypospadias) to be as normal as nonaffected, circumcised genitals. © 2015 International Society for Sexual Medicine.

  11. Laser-Camera Vision Sensing for Spacecraft Mobile Robot Navigation

    NASA Technical Reports Server (NTRS)

    Maluf, David A.; Khalil, Ahmad S.; Dorais, Gregory A.; Gawdiak, Yuri

    2002-01-01

    The advent of spacecraft mobile robots-free-flyng sensor platforms and communications devices intended to accompany astronauts or remotely operate on space missions both inside and outside of a spacecraft-has demanded the development of a simple and effective navigation schema. One such system under exploration involves the use of a laser-camera arrangement to predict relative positioning of the mobile robot. By projecting laser beams from the robot, a 3D reference frame can be introduced. Thus, as the robot shifts in position, the position reference frame produced by the laser images is correspondingly altered. Using normalization and camera registration techniques presented in this paper, the relative translation and rotation of the robot in 3D are determined from these reference frame transformations.

  12. Wind turbine generator with improved operating subassemblies

    DOEpatents

    Cheney, Jr., Marvin C.

    1985-01-01

    A wind turbine includes a yaw spring return assembly to return the nacelle from a position to which it has been rotated by yawing forces, thus preventing excessive twisting of the power cables and control cables. It also includes negative coning restrainers to limit the bending of the flexible arms of the rotor towards the tower, and stop means on the rotor shaft to orient the blades in a vertical position during periods when the unit is upwind when the wind commences. A pendulum pitch control mechanism is improved by orienting the pivot axis for the pendulum arm at an angle to the longitudinal axis of its support arm, and excessive creep is of the synthetic resin flexible beam support for the blades is prevented by a restraining cable which limits the extent of pivoting of the pendulum during normal operation but which will permit further pivoting under abnormal conditions to cause the rotor to stall.

  13. The use of a tactile interface to convey position and motion perceptions

    NASA Technical Reports Server (NTRS)

    Rupert, A. H.; Guedry, F. E.; Reschke, M. F.

    1994-01-01

    Under normal terrestrial conditions, perception of position and motion is determined by central nervous system integration of concordant and redundant information from multiple sensory channels (somatosensory, vestibular, visual), which collectively yield vertical perceptions. In the acceleration environment experienced by the pilots, the somatosensory and vestibular sensors frequently present false information concerning the direction of gravity. When presented with conflicting sensory information, it is normal for pilots to experience episodes of disorientation. We have developed a tactile interface that obtains vertical roll and pitch information from a gyro-stabilized attitude indicator and maps this information in a one-to-one correspondence onto the torso of the body using a matrix of vibrotactors. This enables the pilot to continuously maintain an awareness of aircraft attitude without reference to visual cues, utilizing a sensory channel that normally operates at the subconscious level. Although initially developed to improve pilot spatial awareness, this device has obvious applications to 1) simulation and training, 2) nonvisual tracking of targets, which can reduce the need for pilots to make head movements in the high-G environment of aerial combat, and 3) orientation in environments with minimal somatosensory cues (e.g., underwater) or gravitational cues (e.g., space).

  14. Exploring the mammalian sensory space: co-operations and trade-offs among senses.

    PubMed

    Nummela, Sirpa; Pihlström, Henry; Puolamäki, Kai; Fortelius, Mikael; Hemilä, Simo; Reuter, Tom

    2013-12-01

    The evolution of a particular sensory organ is often discussed with no consideration of the roles played by other senses. Here, we treat mammalian vision, olfaction and hearing as an interconnected whole, a three-dimensional sensory space, evolving in response to ecological challenges. Until now, there has been no quantitative method for estimating how much a particular animal invests in its different senses. We propose an anatomical measure based on sensory organ sizes. Dimensions of functional importance are defined and measured, and normalized in relation to animal mass. For 119 taxonomically and ecologically diverse species, we can define the position of the species in a three-dimensional sensory space. Thus, we can ask questions related to possible trade-off vs. co-operation among senses. More generally, our method allows morphologists to identify sensory organ combinations that are characteristic of particular ecological niches. After normalization for animal size, we note that arboreal mammals tend to have larger eyes and smaller noses than terrestrial mammals. On the other hand, we observe a strong correlation between eyes and ears, indicating that co-operation between vision and hearing is a general mammalian feature. For some groups of mammals we note a correlation, and possible co-operation between olfaction and whiskers.

  15. Luminosity limits for liquid argon calorimetry

    NASA Astrophysics Data System (ADS)

    J, Rutherfoord; B, Walker R.

    2012-12-01

    We have irradiated liquid argon ionization chambers with betas using high-activity Strontium-90 sources. The radiation environment is comparable to that in the liquid argon calorimeters which are part of the ATLAS detector installed at CERN's Large Hadron Collider. We measure the ionization current over a wide range of applied potential for two different source activities and for three different chamber gaps. These studies provide operating experience at exceptionally high ionization rates. We can operate these chambers either in the normal mode or in the space-charge limited regime and thereby determine the transition point between the two. From the transition point we indirectly extract the positive argon ion mobility.

  16. Hydraulically-activated operating system for an electric circuit breaker

    DOEpatents

    Imam, Imdad; Barkan, Philip

    1979-01-01

    This operating system comprises a fluid motor having a piston, a breaker-opening space at one side of the piston, and a breaker-closing space at its opposite side. An accumulator freely communicates with the breaker-opening space for supplying pressurized fluid thereto during a circuit-breaker opening operation. A normally-closed valve located on the breaker-closing-side of the piston is openable to release liquid from the breaker-closing space so that pressurized liquid in the breaker-opening space can drive the piston in an opening direction. Means is provided for restoring the valve to its closed position following the circuit-breaker opening operation. An impeded passage affords communication between the accumulator and the breaker-closing space to allow pressurized liquid to flow from the accumulator to the breaker-closing space and develop a pressure therein substantially equal to accumulator pressure when the valve is restored to closed position following breaker-opening. This passage is so impeded that the flow therethrough from the accumulator into the breaker-closing space is sufficiently low during initial opening motion of the piston through a substantial portion of its opening stroke as to avoid interference with said initial opening motion of the piston.

  17. Improving the Comprehensibility of a Simulated Technical Manual.

    DTIC Science & Technology

    1985-06-20

    dilithium-controlled matter- antimatter conversion system. If you place the power switch Si in the A position, the phaser system gets power. If the indicator...ship’s on-board dilithium-controlled matter- antimatter -plasmation dielectric energy accumulator does not have a Normal Operation Indicator on the J-4...standard energon conversion cycle, whereby power generated by the ship’s matter- antimatter conversion system is converted to a 60-gigavolt phase

  18. Idiopathic normal pressure hydrocephalus: the CSF tap-test may predict the clinical response to shunting.

    PubMed

    Sand, T; Bovim, G; Grimse, R; Myhr, G; Helde, G; Cappelen, J

    1994-05-01

    A follow-up study was performed in nine patients with idiopathic normal pressure hydrocephalus (NPH) 37 months (mean) after shunting and 10 non-operated controls with comparable degrees of ventricular enlargement, gait disorder, and dementia. Five operated patients vs. no controls reported sustained general improvement (p < 0.02). Objectively improved gait at follow-up (compared with preoperative status) was found in five of the six tested NPH-patients vs. none of the controls (p < 0.005). Improved gait and/or psychometric function was found in four of six NPH vs. none of eight control patients (p < 0.02) after drainage of 40 ml cerebrospinal fluid (CSF tap-test). Improved gait during the CSF tap-test predicted continued improvement at follow-up. Temporal horn size was the only radiological variable which showed a (moderate) positive correlation with resistance to CSF absorption and rate of pressure increase. The size of the third ventricle diminished in parallel with clinical improvement.

  19. Effect of obesity on preterm delivery prediction by transabdominal recording of uterine electromyography.

    PubMed

    Lucovnik, Miha; Chambliss, Linda R; Blumrick, Richard; Balducci, James; Gersak, Ksenija; Garfield, Robert E

    2016-10-01

    It has been shown that noninvasive uterine electromyography (EMG) can identify true preterm labor more accurately than methods available to clinicians today. The objective of this study was to evaluate the effect of body mass index (BMI) on the accuracy of uterine EMG in predicting preterm delivery. Predictive values of uterine EMG for preterm delivery were compared in obese versus overweight/normal BMI patients. Hanley-McNeil test was used to compare receiver operator characteristics curves in these groups. Previously reported EMG cutoffs were used to determine groups with false positive/false negative and true positive/true negative EMG results. BMI in these groups was compared with Student t test (p < 0.05 significant). A total of 88 patients were included: 20 obese, 64 overweight, and four with normal BMI. EMG predicted preterm delivery within 7 days with area under the curve = 0.95 in the normal/overweight group, and with area under the curve = 1.00 in the obese group (p = 0.08). Six patients in true preterm labor (delivering within 7 days from EMG measurement) had low EMG values (false negative group). There were no false positive results. No significant differences in patient's BMI were noted between false negative group patients and preterm labor patients with high EMG values (true positive group) and nonlabor patients with low EMG values (true negative group; p = 0.32). Accuracy of noninvasive uterine EMG monitoring and its predictive value for preterm delivery are not affected by obesity. Copyright © 2016. Published by Elsevier B.V.

  20. Exploring the concept and use of positive deviance in nursing.

    PubMed

    Gary, Jodie C

    2013-08-01

    Positive deviance involves an intentional act of breaking the rules in order to serve the greater good. For nurses, the rightness or wrongness of such actions will be judged by other people who are in charge of rules enforcement; but the decision to engage in positive deviance lies solely with the nurse. There is no uniform or consistent definition of positive deviance. This article uses the Walker and Avant method of concept analysis to explore and identify the essence of the term positive deviance in the nursing practice environment, provide a better understanding of the concept, and clarify its meaning for the nursing profession. In turn this led to an operational definition: positive deviance is intentional and honorable behavior that departs or differs from an established norm; contains elements of innovation, creativity, adaptability, or a combination thereof; and involves risk for the nurse. The concept of positive deviance is useful, offering nurses a basis for decision making when the normal, expected actions collide with the nurse's view of the right thing to do.

  1. Effects of Sampling and Spatio/Temporal Granularity in Traffic Monitoring on Anomaly Detectability

    NASA Astrophysics Data System (ADS)

    Ishibashi, Keisuke; Kawahara, Ryoichi; Mori, Tatsuya; Kondoh, Tsuyoshi; Asano, Shoichiro

    We quantitatively evaluate how sampling and spatio/temporal granularity in traffic monitoring affect the detectability of anomalous traffic. Those parameters also affect the monitoring burden, so network operators face a trade-off between the monitoring burden and detectability and need to know which are the optimal paramter values. We derive equations to calculate the false positive ratio and false negative ratio for given values of the sampling rate, granularity, statistics of normal traffic, and volume of anomalies to be detected. Specifically, assuming that the normal traffic has a Gaussian distribution, which is parameterized by its mean and standard deviation, we analyze how sampling and monitoring granularity change these distribution parameters. This analysis is based on observation of the backbone traffic, which exhibits spatially uncorrelated and temporally long-range dependence. Then we derive the equations for detectability. With those equations, we can answer the practical questions that arise in actual network operations: what sampling rate to set to find the given volume of anomaly, or, if the sampling is too high for actual operation, what granularity is optimal to find the anomaly for a given lower limit of sampling rate.

  2. Perforated peptic ulcer in southeastern Taiwan.

    PubMed

    Li, Chin-Hsien; Chang, Wen-Hsiung; Shih, Shou-Chuan; Lin, Shee-Chan; Bair, Ming-Jong

    2010-09-01

    No studies focus on the population with perforated peptic ulcer in southeastern Taiwan. The present study aimed to assess the differences between the different races and the risk factors related to mortality and morbidity in postoperative patients in southeastern Taiwan. The medical records of 237 patients were reviewed retrospectively. The following factors were analyzed: patient profiles, coexisting illnesses, diagnostic method, fever, preoperative shock, clinical data at emergency room, delay operation, site of perforation, operative method, positive ascites culture, species of microbes in ascites culture, postoperative complications, death and the length of hospital stay. Aborigines were significantly different from non-aborigines in the ratio of female cases and in the habits of alcohol drinking and betel nut chewing. There were also four significantly different variables between them: fever, hemoglobin value, site of perforation and operative method. Total postoperative complication rate was 41.3% and 39 patients (16.6%) died. In multivariate analysis, age > or = 65 years, lipase > upper normal limit and preoperative shock were independent predictors of mortality. Significant risk factors associated with morbidity were NSAIDs use, creatinine > 1.5 mg/dL and preoperative shock. Aborigines were different from non-aborigines in several categories. In southeastern Taiwan, NSAIDs use, creatinine > 1.5 mg/dL and preoperative shock were independent risk factors of morbidity, and age > or = 65 years, lipase > upper normal limit and preoperative shock were independent risk factors of mortality in postoperative perforated peptic ulcer. Lipase > upper normal limit is needed for further research on the influence on mortality.

  3. An energy-saving nonlinear position control strategy for electro-hydraulic servo systems.

    PubMed

    Baghestan, Keivan; Rezaei, Seyed Mehdi; Talebi, Heidar Ali; Zareinejad, Mohammad

    2015-11-01

    The electro-hydraulic servo system (EHSS) demonstrates numerous advantages in size and performance compared to other actuation methods. Oftentimes, its utilization in industrial and machinery settings is limited by its inferior efficiency. In this paper, a nonlinear backstepping control algorithm with an energy-saving approach is proposed for position control in the EHSS. To achieve improved efficiency, two control valves including a proportional directional valve (PDV) and a proportional relief valve (PRV) are used to achieve the control objectives. To design the control algorithm, the state space model equations of the system are transformed to their normal form and the control law through the PDV is designed using a backstepping approach for position tracking. Then, another nonlinear set of laws is derived to achieve energy-saving through the PRV input. This control design method, based on the normal form representation, imposes internal dynamics on the closed-loop system. The stability of the internal dynamics is analyzed in special cases of operation. Experimental results verify that both tracking and energy-saving objectives are satisfied for the closed-loop system. Copyright © 2015 ISA. Published by Elsevier Ltd. All rights reserved.

  4. [A case of medulla oblongata compression by tortuous vertebral arteries presenting with spastic quadriplegia].

    PubMed

    Kamada, Takashi; Tateishi, Takahisa; Yamashita, Tamayo; Nagata, Shinji; Ohyagi, Yasumasa; Kira, Jun-Ichi

    2013-01-01

    We report a 58-year-old man showing spastic paraparesis due to medulla oblongata compression by tortuous vertebral arteries. He noticed weakness of both legs and gait disturbance at the age of 58 years and his symptoms progressively worsened during the following several months. General physical findings were normal. Blood pressure was normal and there were no signs of arteriosclerosis. Neurological examination on admission revealed lower-limb-dominant spasticity in all four extremities, lower-limb weakness, hyperreflexia in all extremities with positive Wartenberg's, Babinski's and Chaddock's signs, mild hypesthesia and hypopallesthesia in both lower limbs, and spastic gait. Cranial nerves were all normal. Serum was negative for antibodies against human T-cell lymphotropic virus-1 antibody. Nerve conduction and needle electromyographic studies of all four limbs revealed normal findings. Cervical, thoracic and lumbo-sacral magnetic resonance imaging (MRI) findings were all normal. Brain MRI and magnetic resonance angiography demonstrated bilateral tortuous vertebral arteries compressing the medulla oblongata. Neurovascular decompression of the right vertebral artery was performed because compression of the right side was more severe than that of the left side. Post-operative MRI revealed outward translocation of the right vertebral artery and relieved compression of the medulla oblongata on the right side. The patient's symptoms and neurological findings improved gradually after the operation. Bilateral pyramidal tract signs without cranial nerve dysfunction due to compression of the medulla oblongata by tortuous vertebral arteries are extremely rare and clinically indistinguishable from hereditary spastic paraplegia (HSP). Although we did not perform a genetic test for HSP, we consider that the spastic paraparesis and mild lower-limb hypesthesia were caused by compression of the medulla oblongata by bilateral tortuous vertebral arteries based on the post-operative improvement in symptoms. Given the favorable effects of surgery, tortuous vertebral arteries should be considered in the differential diagnosis of patients presenting with progressive spastic paraparesis.

  5. Operational calibration of Geostationary Operational Environmental Satellite-8 and-9 imagers and sounders.

    PubMed

    Weinreb, M; Jamieson, M; Fulton, N; Chen, Y; Johnson, J X; Bremer, J; Smith, C; Baucom, J

    1997-09-20

    We describe the operational in-orbit calibration of the Geostationary Operational Environmental Satellite (GOES)-8 and-9 imagers and sounders. In the infrared channels the calibration is based on observations of space and an onboard blackbody. The calibration equation expresses radiance as a quadratic in instrument output. To suppress noise in the blackbody sequences, we filter the calibration slopes. The calibration equation also accounts for an unwanted variation of the reflectances of the instruments' scan mirrors with east-west scan position, which was not discovered until the instruments were in orbit. The visible channels are not calibrated, but the observations are provided relative to the level of space and are normalized to minimize east-west striping in the images. Users receive scaled radiances in a GOES variable format (GVAR) data stream. We describe the procedure users can apply to transform GVAR counts into radiances, temperatures, and mode-A counts.

  6. Diagnostic capability of scanning laser polarimetry with variable cornea compensator in Indian patients with early primary open-angle glaucoma.

    PubMed

    Parikh, Rajul S; Parikh, Shefali R; Kumar, Rajesh S; Prabakaran, S; Babu, J Gansesh; Thomas, Ravi

    2008-07-01

    To evaluate the diagnostic ability of scanning laser polarimetry (GDx variable corneal compensator [VCC]) for early glaucoma in Asian Indian eyes. Cross-sectional observational study. Two groups of patients (early glaucoma and normal) who satisfied the inclusion and exclusion criteria were included. Early glaucoma was diagnosed in presence of open angles, characteristic glaucomatous optic disc changes correlating with the visual field (VF) on automated perimetry (VF defect fulfilling at least 2 of 3 Anderson and Patella's criteria with mean deviation >or= -6 decibels). Normal subjects had visual acuity >or= 20/30 and intraocular pressure < 22 mmHg, with a normal optic disc and fields and no ocular abnormality. All patients underwent complete ophthalmic evaluation, including VF examination (24-2/30-2 Swedish interactive threshold algorithm standard program) and imaging with GDx VCC. Sensitivity, specificity, positive predictive value and negative predictive value, area under the receiving operating characteristic curve, and likelihood ratios (LRs) were calculated for various GDx VCC parameters. Seventy-four eyes (74 patients) with early glaucoma and 104 eyes (104 normal subjects) were enrolled. TSNIT Std Dev (temporal-superior-nasal-inferior-temporal standard deviation) had the best combination of sensitivity and specificity-61.3 and 95.2, respectively-followed by nerve fiber index score > 50 (sensitivity, 52.7%; specificity, 99%). Nerve fiber index score > 50 had positive and negative predictive values of 74.3% and 97.6%, respectively, for an assumed glaucoma prevalence of 5%. Nerve fiber index score > 50 had a positive LR (+LR) of 54.8 for early glaucoma. GDx VCC has moderate sensitivity, with high specificity, in the diagnosis of early glaucoma. The high +LR for the nerve fiber index score can provide valuable diagnostic information for individual patients.

  7. Reading instead of reasoning? Predictors of arithmetic skills in children with cochlear implants.

    PubMed

    Huber, Maria; Kipman, Ulrike; Pletzer, Belinda

    2014-07-01

    The aim of the present study was to evaluate whether the arithmetic achievement of children with cochlear implants (CI) was lower or comparable to that of their normal hearing peers and to identify predictors of arithmetic achievement in children with CI. In particular we related the arithmetic achievement of children with CI to nonverbal IQ, reading skills and hearing variables. 23 children with CI (onset of hearing loss in the first 24 months, cochlear implantation in the first 60 months of life, atleast 3 years of hearing experience with the first CI) and 23 normal hearing peers matched by age, gender, and social background participated in this case control study. All attended grades two to four in primary schools. To assess their arithmetic achievement, all children completed the "Arithmetic Operations" part of the "Heidelberger Rechentest" (HRT), a German arithmetic test. To assess reading skills and nonverbal intelligence as potential predictors of arithmetic achievement, all children completed the "Salzburger Lesetest" (SLS), a German reading screening, and the Culture Fair Intelligence Test (CFIT), a nonverbal intelligence test. Children with CI did not differ significantly from hearing children in their arithmetic achievement. Correlation and regression analyses revealed that in children with CI, arithmetic achievement was significantly (positively) related to reading skills, but not to nonverbal IQ. Reading skills and nonverbal IQ were not related to each other. In normal hearing children, arithmetic achievement was significantly (positively) related to nonverbal IQ, but not to reading skills. Reading skills and nonverbal IQ were positively correlated. Hearing variables were not related to arithmetic achievement. Children with CI do not show lower performance in non-verbal arithmetic tasks, compared to normal hearing peers. Copyright © 2014. Published by Elsevier Ireland Ltd.

  8. Inflammatory responses in the muscle coat of stomach and small bowel in the postoperative ileus model of guinea pig.

    PubMed

    Choi, Hong Kyu; Lee, Young Ju; Lee, Young Ho; Park, Jong Pil; Min, Kevin; Park, Hyojin

    2013-11-01

    Small intestinal function returns first after surgery, and then the function of the stomach returns to normal after postoperative ileus (POI). The aim of this study was to investigate inflammatory responses in the muscle coat of stomach and small intestine in guinea pig POI model. The distance of charcoal migration from pylorus to the distal intestine was measured. Hematoxylin and eosin (H&E) and immunohistochemical stain for calprotectin were done from the histologic sections of stomach, jejunum and ileum obtained at 3 and 6 hour after operation. Data were compared between sham operation and POI groups. The distance of charcoal migration was significantly reduced in the 3 and 6 hour POI groups compared with sham operated groups (p<0.05). On H&E staining, the degree of inflammation was significantly higher in the stomach of 3 hour POI groups compared with jejunum and ileum of POI groups or sham operated groups (p<0.05). Calprotectin positive cells were significantly increased in the muscle coat of stomach of 3 hour POI groups compared with jejunum and ileum of POI groups or sham operated groups (p<0.05). There was strong association between the degree of inflammation and calprotectin positive cells in stomach. Postoperative ileus induced by cecal manipulation significantly increased the degree of inflammation and calprotectin positive cells in the muscle coat of stomach as a remote organ. The relevance of degree of inflammation and the recovery time of ileus should be pursued in the future research.

  9. Spectrally Encoded Confocal Microscopy (SECM) for Diagnosing of Breast Cancer in Excision and Margin Specimens

    PubMed Central

    Brachtel, Elena F.; Johnson, Nicole B.; Huck, Amelia E.; Rice-Stitt, Travis L.; Vangel, Mark G.; Smith, Barbara L.; Tearney, Guillermo J.; Kang, Dongkyun

    2016-01-01

    A large percentage of breast cancer patients treated with breast conserving surgery need to undergo multiple surgeries due to positive margins found during post-operative margin assessment. Carcinomas could be removed completely during the initial surgery and additional surgery avoided if positive margins can be determined intra-operatively. Spectrally-encoded confocal microscopy (SECM) is a high-speed reflectance confocal microscopy technology that has a potential to rapidly image the entire surgical margin at sub-cellular resolution and accurately determine margin status intra-operatively. In this paper, in order to test feasibility of using SECM for intra-operative margin assessment, we have evaluated the diagnostic accuracy of SECM for detecting various types of breast cancers. Forty-six surgically-removed breast specimens were imaged with a SECM system. Side-by-side comparison between SECM and histologic images showed that SECM images can visualize key histomorphologic patterns of normal/benign and malignant breast tissues. Small (500 µm × 500 µm) spatially-registered SECM and histologic images (n=124 for each) were diagnosed independently by three pathologists with expertise in breast pathology. Diagnostic accuracy of SECM for determining malignant tissues was high, average sensitivity of 0.91, specificity of 0.93, positive predictive value of 0.95, and negative predictive value of 0.87. Intra-observer agreement and inter-observer agreement for SECM were also high, 0.87 and 0.84, respectively. Results from this study suggest that SECM may be developed into an intra-operative margin assessment tool for guiding breast cancer excisions. PMID:26779830

  10. Correction of distal hypospadias: ventral adaption of the prepuce and meatal advancement.

    PubMed

    Persson-Jünemann, C; Seemann, O; Köhrmann, K U; Potempa, D; Jünemann, K P; Alken, P

    1993-01-01

    In distal hypospadias without chordee, surgical correction has a purely cosmetic character. In contrast to standard techniques focusing on meatal position, parents often regard the redundant dorsal prepuce and its missing ventral fusion as the essential constituent of this malformation. The operative technique, presented in detail, emphasizes on foreskin reconstruction. The ventral adaption of the prepuce (VAP procedure) results in a penis with normal appearance. Complications presented reveal the importance of proper patient selection.

  11. The Lateral Meniscus as a Guide to Anatomical Tibial Tunnel Placement During Anterior Cruciate Ligament Reconstruction.

    PubMed

    Kassam, A M; Tillotson, L; Schranz, P J; Mandalia, V I

    2015-01-01

    The aim of the study is to show, on an MRI scan, that the posterior border of the anterior horn of the lateral meniscus (AHLM) could guide tibial tunnel position in the sagittal plane and provide anatomical graft position. One hundred MRI scans were analysed with normal cruciate ligaments and no evidence of meniscal injury. We measured the distance between the posterior border of the AHLM and the midpoint of the ACL by superimposing sagittal images. The mean distance between the posterior border of the AHLM and the ACL midpoint was -0.1mm (i.e. 0.1mm posterior to the ACL midpoint). The range was 5mm to -4.6mm. The median value was 0.0mm. 95% confidence interval was from -0.5 to 0.3mm. A normal, parametric distribution was observed and Intra- and inter-observer variability showed significant correlation (p<0.05) using Pearsons Correlation test (intra-observer) and Interclass correlation (inter-observer). Using the posterior border of the AHLM is a reproducible and anatomical marker for the midpoint of the ACL footprint in the majority of cases. It can be used intra-operatively as a guide for tibial tunnel insertion and graft placement allowing anatomical reconstruction. There will inevitably be some anatomical variation. Pre-operative MRI assessment of the relationship between AHLM and ACL footprint is advised to improve surgical planning. Level 4.

  12. Multicolor immunofluorescence reveals that p63- and/or K5-positive progenitor cells contribute to normal breast epithelium and usual ductal hyperplasia but not to low-grade intraepithelial neoplasia of the breast.

    PubMed

    Boecker, Werner; Stenman, Göran; Schroeder, Tina; Schumacher, Udo; Loening, Thomas; Stahnke, Lisa; Löhnert, Catharina; Siering, Robert Michael; Kuper, Arthur; Samoilova, Vera; Tiemann, Markus; Korsching, Eberhard; Buchwalow, Igor

    2017-05-01

    We contend that knowledge about the cellular composition of normal breast epithelium is a prerequisite for understanding proliferative breast disease. Against this background, we used multicolor immunofluorescence to study normal breast epithelium and two types of intraepithelial proliferative breast lesion for expression of the p63, basal keratin K5, glandular keratin K8/18, SMA, ER-alpha, and Ki67. We studied eight normal breast epithelium samples, 12 cases of usual ductal hyperplasia, and 33 cases of low-grade intraepithelial neoplasia (9 flat epithelial atypia, 14 low-grade ductal carcinoma in situ and 10 cases of lobular neoplasia). Usual ductal hyperplasia showed striking similarity to normal luminal breast epithelium including p63+ and/or K5+ luminal progenitor cells and the full spectrum of luminal progeny cells. In normal breast epithelium and usual ductal hyperplasia, expression of ER-alpha was associated with lack of expression of the proliferation antigen Ki67. In contrast, we found in both types of low-grade intraepithelial neoplasia robust expression of keratin K8/18 and a positive association between ER-alpha and Ki67 expression. However, these lesions were consistently negative for p63 and/or K5. Our observational study supports the view that usual ductal hyperplasia and low-grade intraepithelial neoplasia are different entities rather than part of a spectrum of the same disease. We propose a new operational model of cell differentiation that may serve to better understand correlations between normal breast epithelium and proliferative breast diseases. From our data we conclude that p63+ and/or K5+ progenitor cells contribute to maintenance of normal epithelium and usual ductal hyperplasia, but not to low-grade intraepithelial neoplasia of the breast.

  13. 28 CFR 42.712 - Exception; normal operation or statutory objective.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 28 Judicial Administration 1 2010-07-01 2010-07-01 false Exception; normal operation or statutory objective. 42.712 Section 42.712 Judicial Administration DEPARTMENT OF JUSTICE NONDISCRIMINATION; EQUAL... Discrimination § 42.712 Exception; normal operation or statutory objective. (a) A recipient may take an action...

  14. On the possibility of connecting a non-operating main circulation pump with three pumps in operation without preliminary coast-down of power-generating unit No. 5 in the Novovoronezh nuclear power plant

    NASA Astrophysics Data System (ADS)

    Vitkovskii, I. L.; Nikonov, S. P.; Ryasnyi, S. I.

    2014-02-01

    The subject of this paper is a transient caused by connection of a standby loop to three operating circulation pumps at the initial reactor heat rate equal to 70% of the rated value without preliminarily reducing it to 30% of the rated level as required by the safe operation regulations. Failure of the following normal operation systems is supposed: the first- and the second-type warning protection systems, all quick-acting reducing devices releasing steam into the auxiliary manifold, the electric heaters of the pressurizer, the pressurizer injection system, the primary cooling circuit fluid makeup/blow-through systems, and the blocking systems to shut down the main circulation pump after the level in the steam generator is exceeded. In addition, it is supposed that, under transient conditions, the valves of the turbine regulation system will be in the position in which they were at the moment of the initial event until generation of the signal for positive closing of the turbine stop valves. The first signal to actuate the reactor emergency protection system (EPS) is skipped. The failure of all quick-acting reducing devices releasing steam into the atmosphere is assumed. In addition to equipment failure, at the moment when the main circulation pump is connected, the operator erroneously puts in a new setting to maintain the power allowable for four pumps in operation-in the calculations it was taken equal to 104% of the rated level at most considering the accuracy of evaluating and maintaining the reactor heat rate-and the working group of the reactor protection and control system (P&CS) starts moving upward. On reaching the set power level, the automatic reactor power regulator stops operating and the P&CS elements remain in the position in which they are at the moment. Compliance with the design safety criteria for the adopted scenario of the transient is demonstrated.

  15. Relevance, Derogation and Permission

    NASA Astrophysics Data System (ADS)

    Stolpe, Audun

    We show that a recently developed theory of positive permission based on the notion of derogation is hampered by a triviality result that indicates a problem with the underlying full-meet contraction operation. We suggest a solution that presupposes a particular normal form for codes of norms, adapted from the theory of relevance through propositional letter sharing. We then establish a correspondence between contractions on sets of norms in input/output logic (derogations), and AGM-style contractions on sets of formulae, and use it as a bridge to migrate results on propositional relevance from the latter to the former idiom. Changing the concept accordingly we show that positive permission now incorporates a relevance requirement that wards off triviality.

  16. Improving diagnostic recognition of primary hyperparathyroidism with machine learning.

    PubMed

    Somnay, Yash R; Craven, Mark; McCoy, Kelly L; Carty, Sally E; Wang, Tracy S; Greenberg, Caprice C; Schneider, David F

    2017-04-01

    Parathyroidectomy offers the only cure for primary hyperparathyroidism, but today only 50% of primary hyperparathyroidism patients are referred for operation, in large part, because the condition is widely under-recognized. The diagnosis of primary hyperparathyroidism can be especially challenging with mild biochemical indices. Machine learning is a collection of methods in which computers build predictive algorithms based on labeled examples. With the aim of facilitating diagnosis, we tested the ability of machine learning to distinguish primary hyperparathyroidism from normal physiology using clinical and laboratory data. This retrospective cohort study used a labeled training set and 10-fold cross-validation to evaluate accuracy of the algorithm. Measures of accuracy included area under the receiver operating characteristic curve, precision (sensitivity), and positive and negative predictive value. Several different algorithms and ensembles of algorithms were tested using the Weka platform. Among 11,830 patients managed operatively at 3 high-volume endocrine surgery programs from March 2001 to August 2013, 6,777 underwent parathyroidectomy for confirmed primary hyperparathyroidism, and 5,053 control patients without primary hyperparathyroidism underwent thyroidectomy. Test-set accuracies for machine learning models were determined using 10-fold cross-validation. Age, sex, and serum levels of preoperative calcium, phosphate, parathyroid hormone, vitamin D, and creatinine were defined as potential predictors of primary hyperparathyroidism. Mild primary hyperparathyroidism was defined as primary hyperparathyroidism with normal preoperative calcium or parathyroid hormone levels. After testing a variety of machine learning algorithms, Bayesian network models proved most accurate, classifying correctly 95.2% of all primary hyperparathyroidism patients (area under receiver operating characteristic = 0.989). Omitting parathyroid hormone from the model did not decrease the accuracy significantly (area under receiver operating characteristic = 0.985). In mild disease cases, however, the Bayesian network model classified correctly 71.1% of patients with normal calcium and 92.1% with normal parathyroid hormone levels preoperatively. Bayesian networking and AdaBoost improved the accuracy of all parathyroid hormone patients to 97.2% cases (area under receiver operating characteristic = 0.994), and 91.9% of primary hyperparathyroidism patients with mild disease. This was significantly improved relative to Bayesian networking alone (P < .0001). Machine learning can diagnose accurately primary hyperparathyroidism without human input even in mild disease. Incorporation of this tool into electronic medical record systems may aid in recognition of this under-diagnosed disorder. Copyright © 2016 Elsevier Inc. All rights reserved.

  17. 45 CFR 91.12 - Definitions of normal operation and statutory objective.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... objective. 91.12 Section 91.12 Public Welfare DEPARTMENT OF HEALTH AND HUMAN SERVICES GENERAL ADMINISTRATION... Standards for Determining Age Discrimination § 91.12 Definitions of normal operation and statutory objective. For purposes of §§ 91.13 and 91.14, the terms normal operation and statutory objective shall have the...

  18. Positive-Buoyancy Rover for Under Ice Mobility

    NASA Technical Reports Server (NTRS)

    Leichty, John M.; Klesh, Andrew T.; Berisford, Daniel F.; Matthews, Jaret B.; Hand, Kevin P.

    2013-01-01

    A buoyant rover has been developed to traverse the underside of ice-covered lakes and seas. The rover operates at the ice/water interface and permits direct observation and measurement of processes affecting freeze- over and thaw events in lake and marine environments. Operating along the 2- D ice-water interface simplifies many aspects of underwater exploration, especially when compared to submersibles, which have difficulty in station-keeping and precision mobility. The buoyant rover consists of an all aluminum body with two aluminum sawtooth wheels. The two independent body segments are sandwiched between four actuators that permit isolation of wheel movement from movement of the central tether spool. For normal operations, the wheels move while the tether spool feeds out line and the cameras on each segment maintain a user-controlled fixed position. Typically one camera targets the ice/water interface and one camera looks down to the lake floor to identify seep sources. Each wheel can be operated independently for precision turning and adjustments. The rover is controlled by a touch- tablet interface and wireless goggles enable real-time viewing of video streamed from the rover cameras. The buoyant rover was successfully deployed and tested during an October 2012 field campaign to investigate methane trapped in ice in lakes along the North Slope of Alaska.

  19. Control System for Prosthetic Devices

    NASA Technical Reports Server (NTRS)

    Bozeman, Richard J. (Inventor)

    1996-01-01

    A control system and method for prosthetic devices is provided. The control system comprises a transducer for receiving movement from a body part for generating a sensing signal associated with that of movement. The sensing signal is processed by a linearizer for linearizing the sensing signal to be a linear function of the magnitude of the distance moved by the body part. The linearized sensing signal is normalized to be a function of the entire range of body part movement from the no-shrug position of the moveable body part through the full-shrg position of the moveable body part. The normalized signal is divided into a plurality of discrete command signals. The discrete command signals are used by typical converter devices which are in operational association with the prosthetic device. The converter device uses the discrete command signals for driving the moveable portions of the prosthetic device and its sub-prosthesis. The method for controlling a prosthetic device associated with the present invention comprises the steps of receiving the movement from the body part, generating a sensing signal in association with the movement of the body part, linearizing the sensing signal to be a linear function of the magnitude of the distance moved by the body part, normalizing the linear signal to be a function of the entire range of the body part movement, dividing the normalized signal into a plurality of discrete command signals, and implementing the plurality of discrete command signals for driving the respective moveable prosthesis device and its sub-prosthesis.

  20. Control system and method for prosthetic devices

    NASA Technical Reports Server (NTRS)

    Bozeman, Richard J., Jr. (Inventor)

    1992-01-01

    A control system and method for prosthetic devices is provided. The control system comprises a transducer for receiving movement from a body part for generating a sensing signal associated with that movement. The sensing signal is processed by a linearizer for linearizing the sensing signal to be a linear function of the magnitude of the distance moved by the body part. The linearized sensing signal is normalized to be a function of the entire range of body part movement from the no-shrug position of the movable body part through the full-shrug position of the movable body part. The normalized signal is divided into a plurality of discrete command signals. The discrete command signals are used by typical converter devices which are in operational association with the prosthetic device. The converter device uses the discrete command signals for driving the movable portions of the prosthetic device and its sub-prosthesis. The method for controlling a prosthetic device associated with the present invention comprises the steps of receiving the movement from the body part, generating a sensing signal in association with the movement of the body part, linearizing the sensing signal to be a linear function of the magnitude of the distance moved by the body part, normalizing the linear signal to be a function of the entire range of the body part movement, dividing the normalized signal into a plurality of discrete command signals, and implementing the plurality of discrete command signals for driving the respective movable prosthesis device and its sub-prosthesis.

  1. Accuracy of Raman spectroscopy in differentiating brain tumor from normal brain tissue.

    PubMed

    Zhang, Jing; Fan, Yimeng; He, Min; Ma, Xuelei; Song, Yanlin; Liu, Ming; Xu, Jianguo

    2017-05-30

    Raman spectroscopy could be applied to distinguish tumor from normal tissues. This meta-analysis was conducted to assess the accuracy of Raman spectroscopy in differentiating brain tumor from normal brain tissue. PubMed and Embase were searched to identify suitable studies prior to Jan 1st, 2016. We estimated the pooled sensitivity, specificity, positive and negative likelihood ratios (LR), diagnostic odds ratio (DOR), and constructed summary receiver operating characteristics (SROC) curves to identity the accuracy of Raman spectroscopy in differentiating brain tumor from normal brain tissue. A total of six studies with 1951 spectra were included. For glioma, the pooled sensitivity and specificity of Raman spectroscopy were 0.96 (95% CI 0.94-0.97) and 0.99 (95% CI 0.98-0.99), respectively. The area under the curve (AUC) was 0.9831. For meningioma, the pooled sensitivity and specificity were 0.98 (95% CI 0.94-1.00) and 1.00 (95% CI 0.98-1.00), respectively. The AUC was 0.9955. This meta-analysis suggested that Raman spectroscopy could be an effective and accurate tool for differentiating glioma and meningioma from normal brain tissue, which would help us both avoid removal of normal tissue and minimize the volume of residual tumor.

  2. Gigapixel surface imaging of radical prostatectomy specimens for comprehensive detection of cancer-positive surgical margins using structured illumination microscopy

    PubMed Central

    Wang, Mei; Tulman, David B.; Sholl, Andrew B.; Kimbrell, Hillary Z.; Mandava, Sree H.; Elfer, Katherine N.; Luethy, Samuel; Maddox, Michael M.; Lai, Weil; Lee, Benjamin R.; Brown, J. Quincy

    2016-01-01

    Achieving cancer-free surgical margins in oncologic surgery is critical to reduce the need for additional adjuvant treatments and minimize tumor recurrence; however, there is a delicate balance between completeness of tumor removal and preservation of adjacent tissues critical for normal post-operative function. We sought to establish the feasibility of video-rate structured illumination microscopy (VR-SIM) of the intact removed tumor surface as a practical and non-destructive alternative to intra-operative frozen section pathology, using prostate cancer as an initial target. We present the first images of the intact human prostate surface obtained with pathologically-relevant contrast and subcellular detail, obtained in 24 radical prostatectomy specimens immediately after excision. We demonstrate that it is feasible to routinely image the full prostate circumference, generating gigapixel panorama images of the surface that are readily interpreted by pathologists. VR-SIM confirmed detection of positive surgical margins in 3 out of 4 prostates with pathology-confirmed adenocarcinoma at the circumferential surgical margin, and furthermore detected extensive residual cancer at the circumferential margin in a case post-operatively classified by histopathology as having negative surgical margins. Our results suggest that the increased surface coverage of VR-SIM could also provide added value for detection and characterization of positive surgical margins over traditional histopathology. PMID:27257084

  3. [Nuclear medicine diagnosis of pulmonary capillary protein leakage].

    PubMed

    Creutzig, H; Sturm, J A; Schober, O; Nerlich, M L; Kant, C J

    1984-10-01

    Pulmonary extravascular albumin extravasation in patients with adult respiratory distress syndrome can be quantified with radionuclide techniques. While imaging procedures with a computerized gamma camera will allow reproducible ROIs, this will be the main limitation in nonimaging measurements with small scintillation probes. Repeated positioning by one operator results in a mean spatial variation of position of about 2 cm and a variation in count rate of 25%. For the estimation of PCPL the small probes must be positioned under scintigraphic control. Under these conditions the results of both techniques are identical. The upper limit of normal was estimated to be 1 x E-5/sec. The standard deviation of abnormal measurements was about 10%. The pulmonary capillary protein leakage can be quantified by radionuclide techniques with good accuracy, using the combination of imaging and nonimaging techniques.

  4. [Comparative study of proximal femoral shortening after the third generation of Gamma nail versus proximal femoral nail anti-rotation in treatment of intertrochanteric fracture].

    PubMed

    Hou, Yu; Yao, Qi; Zhang, Gen'ai; Ding, Lixiang

    2018-03-01

    To explore the difference of the proximal femoral shortening (PFS) between the third generation of Gamma nail (TGN) and the proximal femoral nail anti-rotation (PFNA) in treating intertrochanteric fracture of femur. The clinical data of 158 patients with intertrochanteric fracture of femur who were treated with TGN internal fixation or PFNA internal fixation between January 2014 and December 2015 were retrospectively analysed. The patients were divided into TGN group (69 cases) and PFNA group (89 cases) according to surgical operation. There was no significant difference in gender, age, bone mineral density, causes of injury, AO/Association for the Study of Internal Fixation (AO/ASIF) classification, accompanied disease, and the time from injury to operation between 2 groups ( P >0.05). The result of fracture reduction was divided into 3 types: positive medial cortex support, neutral position cortex support, and negative medial cortex support according to the method of Chang et al . At 18 months postoperatively, bilateral hip anteroposterior X-ray films were taken to measure horizontal PFS values (marked as X), vertical PFS values (marked as Y), and calculate the total PFS values (marked as Z). The PFS values were divided into 4 grades according to the criteria (≤1.0 mm, 1.0-4.9 mm, 5.0-9.9 mm, and ≥10.0 mm), and the constituent ratio was calculated and compared between 2 groups. The X, Y, and Z values and the collodiaphyseal angles of 2 groups at 18 months postoperatively were compared. The X, Y, and Z values of 2 groups of patients with failed fixation and normal healing within 18 months after operation were recorded and compared. The X, Y, and Z values of 2 groups of the patients with different cortex support types were also compared. There were 34 cases of positive medial cortex support, 30 cases of neutral position cortex support, and 5 cases of negative medial cortex support in TGN group, and there were 45, 33, and 11 cases in PFNA group respectively, showing no significant difference between 2 groups ( Z =-1.06, P =0.29). All patients were followed up 18 months after operation. At 18 months after operation, the constituent ratios of PFS values (X, Y, Z) had significant differences between 2 groups ( P <0.05). The patients of shortening of 1.0-4.9 mm and 5.0-9.9 mm were obviously more in TGN group than in PFNA group; the patients of shortening of ≥10.0 mm were obviously more in PFNA group than in TGN group. There were significant differences in X, Y, and Z values between 2 groups ( P <0.05), but no significant difference of the collodiaphysial angle was found between 2 groups ( t =0.47, P =0.64). Six cases of internal fixation failed in TGN group and PFNA group respectively within 3 months after operation, and there was no significant difference of X, Y, and Z values between failed fixation and normal healing patients within 2 groups ( P >0.05). When the reposition effect was the positive medial cortex support, the X, Y, and Z values were significantly lower in TGN group than in PFNA group ( P <0.05); but no significant difference was found between 2 groups when the reposition effect was the neutral position cortex support or negative medial cortex support ( P >0.05). At 18 months after operation, the X, Y, and Z values of the negative medial cortex support patients were significantly higher than those of the positive medial cortex support or the neutral position cortex support patients within 2 groups ( P <0.05). PFS is a common complication of the intertrochanteric fracture of the femur after internal fixation. During operation, the selection of internal fixation should be based on the results of intraoperative reduction. TGN should be applied to reduce PFS if positive medial cortex support happened.

  5. [Strabismus surgery in Grave's disease--dose-effect relationships and functional results].

    PubMed

    Schittkowski, M; Fichter, N; Guthoff, R

    2004-11-01

    Strabismus in thyroid ophthalmopathy is based on a loss of the contractility and distensibility of the external ocular muscles. Different therapeutic approaches are available, such as recession after pre-. or intraoperative measurement, adjustable sutures, antagonist resection, or contralateral synergist faden-operation. 26 patients with strabismus in thyroid ophthalmopathy were operated between 2000 and 2003. All patients were examined preoperatively, then 1 day and 3 - 6 months (maximum 36 months) postoperatively. Before proceeding with surgery, we waited at least 6 months after stabilization of ocular alignment and normalization of thyroid chemistry. Preoperative vertical deviation was 10-44 PD (mean 22), 3 months postoperatively it was 2-10 PD (mean 1.5). Recession of the fibrotic muscle leads to reproducible results: 3.98 +/- 0.52 PD vertical deviation/mm for the inferior rectus. In the case of a large preoperative deviation a correction should be expected, which might not be sufficient in the first few days or weeks; a second operation should not be carried out before 3 months. 7 patients were operated twice, 1 patient need three operations. 4 patients (preop. 0) achieved no double vision at all; 15 patients (preop. 1) had no double vision in the primary and reading positions; 3 patients (preop. 0) had no double vision with a maximum of 5 PD; 1 patient (preop. 7) had double vision in the primary or reading position even with prisms; and 2 patients (preop. 17) had double vision in every position. We advocate that recession of the restricted inferior or internal rectus muscle is precise, safe and effective in patients with thyroid ophthalmopathy. The recessed muscle should be fixed directly at the sclera to avoid late over-correction through a slipped muscle. The success rate in terms of binocular single vision was 76 % and 88 % with prisms added.

  6. ARRANGEMENT FOR REPLACING FILTERS

    DOEpatents

    Blomgren, R.A.; Bohlin, N.J.C.

    1957-08-27

    An improved filtered air exhaust system which may be continually operated during the replacement of the filters without the escape of unfiltered air is described. This is accomplished by hermetically sealing the box like filter containers in a rectangular tunnel with neoprene covered sponge rubber sealing rings coated with a silicone impregnated pneumatic grease. The tunnel through which the filters are pushed is normal to the exhaust air duct. A number of unused filters are in line behind the filters in use, and are moved by a hydraulic ram so that a fresh filter is positioned in the air duct. The used filter is pushed into a waiting receptacle and is suitably disposed. This device permits a rapid and safe replacement of a radiation contaminated filter without interruption to the normal flow of exhaust air.

  7. Predictors of recurrence in pheochromocytoma.

    PubMed

    Press, Danielle; Akyuz, Muhammet; Dural, Cem; Aliyev, Shamil; Monteiro, Rosebel; Mino, Jeff; Mitchell, Jamie; Hamrahian, Amir; Siperstein, Allan; Berber, Eren

    2014-12-01

    The recurrence rate of pheochromocytoma after adrenalectomy is 6.5-16.5%. This study aims to identify predictors of recurrence and optimal biochemical testing and imaging for detecting the recurrence of pheochromocytoma. In this retrospective study we reviewed all patients who underwent adrenalectomy for pheochromocytoma during a 14-year period at a single institution. One hundred thirty-five patients had adrenalectomy for pheochromocytoma. Eight patients (6%) developed recurrent disease. The median time from initial operation to diagnosis of recurrence was 35 months. On multivariate analysis, tumor size >5 cm was an independent predictor of recurrence. One patient with recurrence died, 4 had stable disease, 2 had progression of disease, and 1 was cured. Recurrence was diagnosed by increases in plasma and/or urinary metanephrines and positive imaging in 6 patients (75%), and by positive imaging and normal biochemical levels in 2 patients (25%). Patients with large tumors (>5 cm) should be followed vigilantly for recurrence. Because 25% of patients with recurrence had normal biochemical levels, we recommend routine imaging and testing of plasma or urinary metanephrines for prompt diagnosis of recurrence. Copyright © 2014 Elsevier Inc. All rights reserved.

  8. Seroprevalence of Toxocara canis infection in tropical Venezuela.

    PubMed

    Lynch, N R; Eddy, K; Hodgen, A N; Lopez, R I; Turner, K J

    1988-01-01

    An enzyme-linked immunosorbent assay (ELISA) was used to determine the seroprevalence of Toxocara canis infection in different socio-economic groups of the tropical population of Venezuela. The lack of definitive independent diagnostic criteria for toxocariasis required the establishment of operational upper limits of normality for Toxocara ELISA values, based upon their log-normalized distribution in a presumptive "non-toxocariasis" sub-population. Only 1.8% of urban subjects of medium-high socio-economic level were considered to be clearly positive in Toxocara ELISA, compared to 20.0% of urban slum dwellers, 25.6% rural subsistence farmers and 34.9% Amazon Indians. As the test was performed using excretory-secretory antigen, and under conditions of competitive inhibition by soluble extracts of non-homologous parasites, co-infection by common intestinal helminths, protozoa or other organisms did not give rise to false positive results. However, strong cross-reactivity with Onchocerca volvulus may have influenced the prevalence figure obtained for the Amazon Indians. These results indicate that T. canis is yet another parasite that is widely distributed in economically underprivileged tropical populations.

  9. CNV detection method optimized for high-resolution arrayCGH by normality test.

    PubMed

    Ahn, Jaegyoon; Yoon, Youngmi; Park, Chihyun; Park, Sanghyun

    2012-04-01

    High-resolution arrayCGH platform makes it possible to detect small gains and losses which previously could not be measured. However, current CNV detection tools fitted to early low-resolution data are not applicable to larger high-resolution data. When CNV detection tools are applied to high-resolution data, they suffer from high false-positives, which increases validation cost. Existing CNV detection tools also require optimal parameter values. In most cases, obtaining these values is a difficult task. This study developed a CNV detection algorithm that is optimized for high-resolution arrayCGH data. This tool operates up to 1500 times faster than existing tools on a high-resolution arrayCGH of whole human chromosomes which has 42 million probes whose average length is 50 bases, while preserving false positive/negative rates. The algorithm also uses a normality test, thereby removing the need for optimal parameters. To our knowledge, this is the first formulation for CNV detecting problems that results in a near-linear empirical overall complexity for real high-resolution data. Copyright © 2012 Elsevier Ltd. All rights reserved.

  10. 75 FR 62476 - Ultra-Wideband Transmission Systems

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-10-12

    ... would be obtained from measurements taken with the system operating in its normal operating mode. At the... with the transmitter operating continuously at a fundamental transmission frequency. 9. Subsequent to... systems, measured in their normal operating modes, is less than that of a UWB transmitter employing...

  11. Synchronous motor with soft start element formed between the motor rotor and motor output shaft to successfully synchronize loads that have high inertia and/or high torque

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Umans, Stephen D; Nisley, Donald L; Melfi, Michael J

    A line-start synchronous motor has a housing, a rotor shaft, and an output shaft. A soft-start coupling portion is operatively coupled to the output shaft and the rotor shaft. The soft-start coupling portion is configurable to enable the synchronous motor to obtain synchronous operation and to drive, at least near synchronous speed during normal steady state operation of the motor, a load having characteristics sufficient to prevent obtaining normal synchronous operation of the motor when the motor is operatively connected to the load in the absence of the soft-start coupling. The synchronous motor is sufficiently rated to obtain synchronous operationmore » and to drive, at least near synchronous speed during normal steady state operation of the motor, a load having characteristics sufficient to prevent obtaining normal synchronous operation of the motor when the motor is operatively connected to the load in the absence of the soft-start coupling.« less

  12. Alarm toe switch

    DOEpatents

    Ganyard, Floyd P.

    1982-01-01

    An alarm toe switch inserted within a shoe for energizing an alarm circuit n a covert manner includes an insole mounting pad into which a miniature reed switch is fixedly molded. An elongated slot perpendicular to the reed switch is formed in the bottom surface of the mounting pad. A permanent cylindrical magnet positioned in the forward portion of the slot with a diameter greater than the pad thickness causes a bump above the pad. A foam rubber block is also positioned in the slot rearwardly of the magnet and holds the magnet in normal inoperative relation. A non-magnetic support plate covers the slot and holds the magnet and foam rubber in the slot. The plate minimizes bending and frictional forces to improve movement of the magnet for reliable switch activation. The bump occupies the knuckle space beneath the big toe. When the big toe is scrunched rearwardly the magnet is moved within the slot relative to the reed switch, thus magnetically activating the switch. When toe pressure is released the foam rubber block forces the magnet back into normal inoperative position to deactivate the reed switch. The reed switch is hermetically sealed with the magnet acting through the wall so the switch assembly S is capable of reliable operation even in wet and corrosive environments.

  13. Human reliability and plant operating efficiency: Are 12-hour work schedules cause for concern

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baker, T.L.

    1992-01-01

    Since the introduction of 12-h shifts to the US nuclear power industry only 8 yr ago, compressed workweek schedules have proliferated among operations departments at a phenomenal rate. Many plants that continue to use 8-h shifts during normal operations routinely change to scheduled 12-h shifts during refueling or maintenance outages. The most critical issue in the use of extended work shifts is whether alertness, physical stamina, or mental performance are compromised to the point of reducing safety or efficiency of nuclear power plant operation. Laboratory and field research sponsored by the National Institute of Occupational Safety and Health suggests thatmore » alertness, measured by self-ratings, and mental performance, measured by computer-based performance tests, are impaired on 12-h shifts compared with 8-h shifts. In contrast to these findings, plant operating efficiency and operator performance have been rated as improved in two field studies conducted in operating nuclear power plants (Fast Flux Test Facility, Washington and Ontario Hydro, Canada). A recent Electric Power Research Institute review of nuclear industry experience with 12-h shifts also suggests an overwhelmingly positive rating of 12-h schedules from both control room operators and management.« less

  14. Adaptive model training system and method

    DOEpatents

    Bickford, Randall L; Palnitkar, Rahul M; Lee, Vo

    2014-04-15

    An adaptive model training system and method for filtering asset operating data values acquired from a monitored asset for selectively choosing asset operating data values that meet at least one predefined criterion of good data quality while rejecting asset operating data values that fail to meet at least the one predefined criterion of good data quality; and recalibrating a previously trained or calibrated model having a learned scope of normal operation of the asset by utilizing the asset operating data values that meet at least the one predefined criterion of good data quality for adjusting the learned scope of normal operation of the asset for defining a recalibrated model having the adjusted learned scope of normal operation of the asset.

  15. Adaptive model training system and method

    DOEpatents

    Bickford, Randall L; Palnitkar, Rahul M

    2014-11-18

    An adaptive model training system and method for filtering asset operating data values acquired from a monitored asset for selectively choosing asset operating data values that meet at least one predefined criterion of good data quality while rejecting asset operating data values that fail to meet at least the one predefined criterion of good data quality; and recalibrating a previously trained or calibrated model having a learned scope of normal operation of the asset by utilizing the asset operating data values that meet at least the one predefined criterion of good data quality for adjusting the learned scope of normal operation of the asset for defining a recalibrated model having the adjusted learned scope of normal operation of the asset.

  16. Flight control actuation system

    NASA Technical Reports Server (NTRS)

    Wingett, Paul T. (Inventor); Gaines, Louie T. (Inventor); Evans, Paul S. (Inventor); Kern, James I. (Inventor)

    2004-01-01

    A flight control actuation system comprises a controller, electromechanical actuator and a pneumatic actuator. During normal operation, only the electromechanical actuator is needed to operate a flight control surface. When the electromechanical actuator load level exceeds 40 amps positive, the controller activates the pneumatic actuator to offset electromechanical actuator loads to assist the manipulation of flight control surfaces. The assistance from the pneumatic load assist actuator enables the use of an electromechanical actuator that is smaller in size and mass, requires less power, needs less cooling processes, achieves high output forces and adapts to electrical current variations. The flight control actuation system is adapted for aircraft, spacecraft, missiles, and other flight vehicles, especially flight vehicles that are large in size and travel at high velocities.

  17. Flight control actuation system

    NASA Technical Reports Server (NTRS)

    Wingett, Paul T. (Inventor); Gaines, Louie T. (Inventor); Evans, Paul S. (Inventor); Kern, James I. (Inventor)

    2006-01-01

    A flight control actuation system comprises a controller, electromechanical actuator and a pneumatic actuator. During normal operation, only the electromechanical actuator is needed to operate a flight control surface. When the electromechanical actuator load level exceeds 40 amps positive, the controller activates the pneumatic actuator to offset electromechanical actuator loads to assist the manipulation of flight control surfaces. The assistance from the pneumatic load assist actuator enables the use of an electromechanical actuator that is smaller in size and mass, requires less power, needs less cooling processes, achieves high output forces and adapts to electrical current variations. The flight control actuation system is adapted for aircraft, spacecraft, missiles, and other flight vehicles, especially flight vehicles that are large in size and travel at high velocities.

  18. Quantum probability rule: a generalization of the theorems of Gleason and Busch

    NASA Astrophysics Data System (ADS)

    Barnett, Stephen M.; Cresser, James D.; Jeffers, John; Pegg, David T.

    2014-04-01

    Busch's theorem deriving the standard quantum probability rule can be regarded as a more general form of Gleason's theorem. Here we show that a further generalization is possible by reducing the number of quantum postulates used by Busch. We do not assume that the positive measurement outcome operators are effects or that they form a probability operator measure. We derive a more general probability rule from which the standard rule can be obtained from the normal laws of probability when there is no measurement outcome information available, without the need for further quantum postulates. Our general probability rule has prediction-retrodiction symmetry and we show how it may be applied in quantum communications and in retrodictive quantum theory.

  19. Chimney for enhancing flow of coolant water in natural circulation boiling water reactor

    DOEpatents

    Oosterkamp, Willem Jan; Marquino, Wayne

    1999-01-05

    A chimney which can be reconfigured or removed during refueling to allow vertical removal of the fuel assemblies. The chimney is designed to be collapsed or dismantled. Collapse or dismantlement of the chimney reduces the volume required for chimney storage during the refueling operation. Alternatively, the chimney has movable parts which allow reconfiguration of its structure. In a first configuration suitable for normal reactor operation, the chimney is radially constricted such that the chimney obstructs vertical removal of the fuel assemblies. In a second configuration suitable for refueling or maintenance of the fuel core, the parts of the chimney which obstruct access to the fuel assemblies are moved radially outward to positions whereat access to the fuel assemblies is not obstructed.

  20. Genetic separation of phototropism and blue light inhibition of stem elongation

    NASA Technical Reports Server (NTRS)

    Liscum, E.; Young, J. C.; Poff, K. L.; Hangarter, R. P.

    1992-01-01

    Blue light-induced regulation of cell elongation is a component of the signal response pathway for both phototropic curvature and inhibition of stem elongation in higher plants. To determine if blue light regulates cell elongation in these responses through shared or discrete pathways, phototropism and hypocotyl elongation were investigated in several blue light response mutants in Arabidopsis thaliana. Specifically, the blu mutants that lack blue light-dependent inhibition of hypocotyl elongation were found to exhibit a normal phototropic response. In contrast, a phototropic null mutant (JK218) and a mutant that has a 20- to 30-fold shift in the fluence dependence for first positive phototropism (JK224) showed normal inhibition of hypocotyl elongation in blue light. F1 progeny of crosses between the blu mutants and JK218 showed normal phototropism and inhibition of hypocotyl elongation, and approximately 1 in 16 F2 progeny were double mutants lacking both responses. Thus, blue light-dependent inhibition of hypocotyl elongation and phototropism operate through at least some genetically distinct components.

  1. 40 CFR 63.2862 - What records must I keep?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ...) initial startup period or the § 63.2850(e)(2) malfunction period. Complete both plans before the... such as normal operation, nonoperating, initial startup period, malfunction period, or exempt operation... inventory. (ii) The operating status of your source such as normal operation, nonoperating, initial startup...

  2. 40 CFR 63.2862 - What records must I keep?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ...) initial startup period or the § 63.2850(e)(2) malfunction period. Complete both plans before the... such as normal operation, nonoperating, initial startup period, malfunction period, or exempt operation... inventory. (ii) The operating status of your source such as normal operation, nonoperating, initial startup...

  3. 40 CFR 63.2862 - What records must I keep?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ...) initial startup period or the § 63.2850(e)(2) malfunction period. Complete both plans before the... such as normal operation, nonoperating, initial startup period, malfunction period, or exempt operation... inventory. (ii) The operating status of your source such as normal operation, nonoperating, initial startup...

  4. 40 CFR 63.2862 - What records must I keep?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...) initial startup period or the § 63.2850(e)(2) malfunction period. Complete both plans before the... such as normal operation, nonoperating, initial startup period, malfunction period, or exempt operation... inventory. (ii) The operating status of your source such as normal operation, nonoperating, initial startup...

  5. 40 CFR 63.2862 - What records must I keep?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...) initial startup period or the § 63.2850(e)(2) malfunction period. Complete both plans before the... such as normal operation, nonoperating, initial startup period, malfunction period, or exempt operation... inventory. (ii) The operating status of your source such as normal operation, nonoperating, initial startup...

  6. Intraoperative computed tomography with integrated navigation system in a multidisciplinary operating suite.

    PubMed

    Uhl, Eberhard; Zausinger, Stefan; Morhard, Dominik; Heigl, Thomas; Scheder, Benjamin; Rachinger, Walter; Schichor, Christian; Tonn, Jörg-Christian

    2009-05-01

    We report our preliminary experience in a prospective series of patients with regard to feasibility, work flow, and image quality using a multislice computed tomographic (CT) scanner combined with a frameless neuronavigation system (NNS). A sliding gantry 40-slice CT scanner was installed in a preexisting operating room. The scanner was connected to a frameless infrared-based NNS. Image data was transferred directly from the scanner into the navigation system. This allowed updating of the NNS during surgery by automated image registration based on the position of the gantry. Intraoperative CT angiography was possible. The patient was positioned on a radiolucent operating table that fits within the bore of the gantry. During image acquisition, the gantry moved over the patient. This table allowed all positions and movements like any normal operating table without compromising the positioning of the patient. For cranial surgery, a carbon-made radiolucent head clamp was fixed to the table. Experience with the first 230 patients confirms the feasibility of intraoperative CT scanning (136 patients with intracranial pathology, 94 patients with spinal lesions). After a specific work flow, interruption of surgery for intraoperative scanning can be limited to 10 to 15 minutes in cranial surgery and to 9 minutes in spinal surgery. Intraoperative imaging changed the course of surgery in 16 of the 230 cases either because control CT scans showed suboptimal screw position (17 of 307 screws, with 9 in 7 patients requiring correction) or that tumor resection was insufficient (9 cases). Intraoperative CT angiography has been performed in 7 cases so far with good image quality to determine residual flow in an aneurysm. Image quality was excellent in spinal and cranial base surgery. The system can be installed in a preexisting operating environment without the need for special surgical instruments. It increases the safety of the patient and the surgeon without necessitating a change in the existing surgical protocol and work flow. Imaging and updating of the NNS can be performed at any time during surgery with very limited time and modification of the surgical setup. Multidisciplinary use increases utilization of the system and thus improves the cost-efficiency relationship.

  7. Improvement in Visual Target Tracking for a Mobile Robot

    NASA Technical Reports Server (NTRS)

    Kim, Won; Ansar, Adnan; Madison, Richard

    2006-01-01

    In an improvement of the visual-target-tracking software used aboard a mobile robot (rover) of the type used to explore the Martian surface, an affine-matching algorithm has been replaced by a combination of a normalized- cross-correlation (NCC) algorithm and a template-image-magnification algorithm. Although neither NCC nor template-image magnification is new, the use of both of them to increase the degree of reliability with which features can be matched is new. In operation, a template image of a target is obtained from a previous rover position, then the magnification of the template image is based on the estimated change in the target distance from the previous rover position to the current rover position (see figure). For this purpose, the target distance at the previous rover position is determined by stereoscopy, while the target distance at the current rover position is calculated from an estimate of the current pose of the rover. The template image is then magnified by an amount corresponding to the estimated target distance to obtain a best template image to match with the image acquired at the current rover position.

  8. Time operators in stroboscopic wave-packet basis and the time scales in tunneling

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bokes, P.

    2011-03-15

    We demonstrate that the time operator that measures the time of arrival of a quantum particle into a chosen state can be defined as a self-adjoint quantum-mechanical operator using periodic boundary conditions and applied to wave functions in energy representation. The time becomes quantized into discrete eigenvalues; and the eigenstates of the time operator, i.e., the stroboscopic wave packets introduced recently [Phys. Rev. Lett. 101, 046402 (2008)], form an orthogonal system of states. The formalism provides simple physical interpretation of the time-measurement process and direct construction of normalized, positive definite probability distribution for the quantized values of the arrival time.more » The average value of the time is equal to the phase time but in general depends on the choice of zero time eigenstate, whereas the uncertainty of the average is related to the traversal time and is independent of this choice. The general formalism is applied to a particle tunneling through a resonant tunneling barrier in one dimension.« less

  9. Applying the LANL Statistical Pattern Recognition Paradigm for Structural Health Monitoring to Data from a Surface-Effect Fast Patrol Boat

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hoon Sohn; Charles Farrar; Norman Hunter

    2001-01-01

    This report summarizes the analysis of fiber-optic strain gauge data obtained from a surface-effect fast patrol boat being studied by the staff at the Norwegian Defense Research Establishment (NDRE) in Norway and the Naval Research Laboratory (NRL) in Washington D.C. Data from two different structural conditions were provided to the staff at Los Alamos National Laboratory. The problem was then approached from a statistical pattern recognition paradigm. This paradigm can be described as a four-part process: (1) operational evaluation, (2) data acquisition & cleansing, (3) feature extraction and data reduction, and (4) statistical model development for feature discrimination. Given thatmore » the first two portions of this paradigm were mostly completed by the NDRE and NRL staff, this study focused on data normalization, feature extraction, and statistical modeling for feature discrimination. The feature extraction process began by looking at relatively simple statistics of the signals and progressed to using the residual errors from auto-regressive (AR) models fit to the measured data as the damage-sensitive features. Data normalization proved to be the most challenging portion of this investigation. A novel approach to data normalization, where the residual errors in the AR model are considered to be an unmeasured input and an auto-regressive model with exogenous inputs (ARX) is then fit to portions of the data exhibiting similar waveforms, was successfully applied to this problem. With this normalization procedure, a clear distinction between the two different structural conditions was obtained. A false-positive study was also run, and the procedure developed herein did not yield any false-positive indications of damage. Finally, the results must be qualified by the fact that this procedure has only been applied to very limited data samples. A more complete analysis of additional data taken under various operational and environmental conditions as well as other structural conditions is necessary before one can definitively state that the procedure is robust enough to be used in practice.« less

  10. COMS normal operation for Earth Observation mission

    NASA Astrophysics Data System (ADS)

    Cho, Young-Min

    2012-09-01

    Communication Ocean Meteorological Satellite (COMS) for the hybrid mission of meteorological observation, ocean monitoring, and telecommunication service was launched onto Geostationary Earth Orbit on June 27, 2010 and it is currently under normal operation service since April 2011. The COMS is located on 128.2° East of the geostationary orbit. In order to perform the three missions, the COMS has 3 separate payloads, the meteorological imager (MI), the Geostationary Ocean Color Imager (GOCI), and the Ka-band antenna. Each payload is dedicated to one of the three missions, respectively. The MI and GOCI perform the Earth observation mission of meteorological observation and ocean monitoring, respectively. For this Earth observation mission the COMS requires daily mission commands from the satellite control ground station and daily mission is affected by the satellite control activities. For this reason daily mission planning is required. The Earth observation mission operation of COMS is described in aspects of mission operation characteristics and mission planning for the normal operation services of meteorological observation and ocean monitoring. And the first year normal operation results after the In-Orbit-Test (IOT) are investigated through statistical approach to provide the achieved COMS normal operation status for the Earth observation mission.

  11. Expression of BMI-1 and Mel-18 in breast tissue - a diagnostic marker in patients with breast cancer

    PubMed Central

    2010-01-01

    Background Polycomb Group (PcG) proteins are epigenetic silencers involved in maintaining cellular identity, and their deregulation can result in cancer. Expression of Mel-18 and Bmi-1 has been studied in tumor tissue, but not in adjacent non-cancerous breast epithelium. Our study compares the expression of the two genes in normal breast epithelium of cancer patients and relates it to the level of expression in the corresponding tumors as well as in breast epithelium of healthy women. Methods A total of 79 tumors, of which 71 malignant tumors of the breast, 6 fibroadenomas, and 2 DCIS were studied and compared to the reduction mammoplastic specimens of 11 healthy women. In addition there was available adjacent cancer free tissue for 23 of the malignant tumors. The tissue samples were stored in RNAlater, RNA was isolated to create expression microarray profile. These two genes were then studied more closely first on mRNA transcription level by microarrays (Agilent 44 K) and quantitative RT-PCR (TaqMan) and then on protein expression level using immunohistochemistry. Results Bmi-1 mRNA is significantly up-regulated in adjacent normal breast tissue in breast cancer patients compared to normal breast tissue from noncancerous patients. Conversely, mRNA transcription level of Mel-18 is lower in normal breast from patients operated for breast cancer compared to breast tissue from mammoplasty. When protein expression of these two genes was evaluated, we observed that most of the epithelial cells were positive for Bmi-1 in both groups of tissue samples, although the expression intensity was stronger in normal tissue from cancer patients compared to mammoplasty tissue samples. Protein expression of Mel-18 showed inversely stronger intensity in tissue samples from mammoplasty compared to normal breast tissue from patients operated for breast cancer. Conclusion Bmi-1 mRNA level is consistently increased and Mel-18 mRNA level is consistently decreased in adjacent normal breast tissue of cancer patients as compared to normal breast tissue in women having had reduction mammoplasties. Bmi-1/Mel-18 ratio can be potentially used as a tool for stratifying women at risk of developing malignancy. PMID:21162745

  12. Transverse occiput position: Using manual Rotation to aid Normal birth and improve delivery OUTcomes (TURN-OUT): A study protocol for a randomised controlled trial.

    PubMed

    de Vries, Bradley; Phipps, Hala; Kuah, Sabrina; Pardey, John; Ludlow, Joanne; Bisits, Andrew; Park, Felicity; Kowalski, David; Hyett, Jon A

    2015-08-18

    Fetal occiput transverse position in the form of deep transverse arrest has long been associated with caesarean section and instrumental vaginal delivery. Occiput transverse position incidentally found in the second stage of labour is also associated with operative delivery in high risk cohorts. There is evidence from cohort studies that prophylactic manual rotation reduces the caesarean section rate. This is a protocol for a double blind, multicentre, randomised, controlled clinical trial to define whether this intervention decreases the operative delivery (caesarean section, forceps or vacuum delivery) rate. Eligible participants will be ≥37 weeks pregnant, with a singleton pregnancy, and a cephalic presentation in the occiput transverse position on transabdominal ultrasound early in the second stage of labour. Based on a background risk of operative delivery of 49%, for a reduction to 35%, an alpha value of 0.05 and a beta value of 0.2, 416 participants will need to be enrolled. Participants will be randomised to either prophylactic manual rotation or a sham procedure. The primary outcome will be operative delivery. Secondary outcomes will be caesarean section, significant maternal mortality and morbidity, and significant perinatal mortality and morbidity. Analysis will be on an intention-to-treat basis. Primary and secondary outcomes will be compared using a chi-squared test. A logistic regression for the primary outcome will be undertaken to account for potential confounders. This study has been approved by the Ethics Review Committee (RPAH Zone) of the Sydney Local Health District, Sydney, Australia, (protocol number: X110410). This trial addresses an important clinical question concerning a commonly used procedure which has the potential to reduce operative delivery and its associated complications. Some issues discussed in the protocol include methods of assessing risk of bias due to inadequate masking of a procedural interventions, variations in intervention efficacy due to operator experience and the recruitment difficulties associated with intrapartum studies. This trial was registered with the Australian New Zealand Clinical Trials Registry (identifier: ACTRN12613000005752 ) on 4 January 2013.

  13. 48 CFR 232.901 - Applicability.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... comptroller, that conditions exist that limit normal business operations; and (iii) Payments will be made in..., invoice, and receiving report) from the operational area. (2) Criteria limiting normal business operations... conditions as— (i) Support infrastructure, hardware, communications capabilities, and bandwidth are not...

  14. Formation and removal of PCDD/Fs in a municipal waste incinerator during different operating periods.

    PubMed

    Wang, Hou Chuan; Hwang, Jyh Feng; Chi, Kai Hsien; Chang, Moo Been

    2007-04-01

    The PCDD/F concentrations and removal efficiencies achieved with air pollution control devices (APCDs) during different operating periods (start-up, normal operation, and shut-down) at an existing municipal waste incinerator (MWI) in Taiwan are evaluated via stack sampling and analysis. The MWI investigated is equipped with electrostatic precipitators (EP), wet scrubbers (WS), and selective catalytic reduction system (SCR) as APCDs. The sampling results indicate that the PCDD/F concentrations at the EP inlet during start-up period were 15 times higher than that measured during normal operation period. The PCDD/F concentration observed at shut-down period was close to that measured at normal operation period. The CO concentration was between 400 and 1000 ppm during start-up period, which was about 50 times higher compared with the normal operation. Hence, combustion condition significantly affected the PCDD/F formation concentration during the waste incineration process. In addition, the distributions of the PCDD/F congeners were similar at different operating periods. During the normal operation and shut-down periods, the EP decreases the PCDD/F concentration (based on TEQ) by 18.4-48.6%, while the removal efficiency of PCDD/Fs achieved with SCR system reaches 99.3-99.6%. Nevertheless, the PCDD/F removal efficiency achieved with SCR was only 42% during the 19-h start-up period due to the low SCR operating temperature (195 degrees C).

  15. Forecasting drought risks for a water supply storage system using bootstrap position analysis

    USGS Publications Warehouse

    Tasker, Gary; Dunne, Paul

    1997-01-01

    Forecasting the likelihood of drought conditions is an integral part of managing a water supply storage and delivery system. Position analysis uses a large number of possible flow sequences as inputs to a simulation of a water supply storage and delivery system. For a given set of operating rules and water use requirements, water managers can use such a model to forecast the likelihood of specified outcomes such as reservoir levels falling below a specified level or streamflows falling below statutory passing flows a few months ahead conditioned on the current reservoir levels and streamflows. The large number of possible flow sequences are generated using a stochastic streamflow model with a random resampling of innovations. The advantages of this resampling scheme, called bootstrap position analysis, are that it does not rely on the unverifiable assumption of normality and it allows incorporation of long-range weather forecasts into the analysis.

  16. [Transsexualism: evaluation of two post-operative transsexuals].

    PubMed

    Palmares Carvalho, Irene

    2008-01-01

    Transsexualism refers to the conviction of belonging to one sex in individuals born with normal sexual characteristics of the other biological sex. The hormonal-surgical treatment of this population has proliferated throughout the past decades and is recent in Portugal. The irreversibility of the sex-reassignment surgery and the lack of knowledge still surrounding transsexualism raises questions that require research in this area. This paper describes a rare-case occurrence of two transsexual brothers who received hormonal-surgical treatment. The evaluation of the treatment is generally very positive, both from the medical and the subjects' points of view. It is only partially positive in terms of personal and social life in the new sex (e.g., reported sensations, humour, social acceptance and success). The individuals' profiles correspond to potentially positive prognostics, and the results suggest that this treatment may have been adequate for these two cases. Future follow-up studies are nevertheless necessary.

  17. Positive direct current corona discharges in single wire-duct electrostatic precipitators

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yehia, Ashraf, E-mail: yehia30161@yahoo.com; Department of Physics, Faculty of Science, Assiut University, Assiut 71516, Arab Republic of Egypt; Abdel-Fattah, E.

    This paper is aimed to study the characteristics of the positive dc corona discharges in single wire-duct electrostatic precipitators. Therefore, the corona discharges were formed inside dry air fed single wire-duct reactor under positive dc voltage at the normal atmospheric conditions. The corona current-voltage characteristics curves have been measured in parallel with the ozone concentration generated inside the reactor under different discharge conditions. The corona current-voltage characteristics curves have agreed with a semi empirical equation derived from the previous studies. The experimental results of the ozone concentration generated inside the reactor were formulated in the form of an empirical equationmore » included the different parameters that were studied experimentally. The obtained equations are valid to expect both the current-voltage characteristics curves and the corresponding ozone concentration that generates with the positive dc corona discharges inside single wire-duct electrostatic precipitators under any operating conditions in the same range of the present study.« less

  18. Performance evaluation of a six-axis generalized force-reflecting teleoperator

    NASA Technical Reports Server (NTRS)

    Hannaford, B.; Wood, L.; Guggisberg, B.; Mcaffee, D.; Zak, H.

    1989-01-01

    Work in real-time distributed computation and control has culminated in a prototype force-reflecting telemanipulation system having a dissimilar master (cable-driven, force-reflecting hand controller) and a slave (PUMA 560 robot with custom controller), an extremely high sampling rate (1000 Hz), and a low loop computation delay (5 msec). In a series of experiments with this system and five trained test operators covering over 100 hours of teleoperation, performance was measured in a series of generic and application-driven tasks with and without force feedback, and with control shared between teleoperation and local sensor referenced control. Measurements defining task performance included 100-Hz recording of six-axis force/torque information from the slave manipulator wrist, task completion time, and visual observation of predefined task errors. The task consisted of high precision peg-in-hole insertion, electrical connectors, velcro attach-de-attach, and a twist-lock multi-pin connector. Each task was repeated three times under several operating conditions: normal bilateral telemanipulation, forward position control without force feedback, and shared control. In shared control, orientation was locally servo controlled to comply with applied torques, while translation was under operator control. All performance measures improved as capability was added along a spectrum of capabilities ranging from pure position control through force-reflecting teleoperation and shared control. Performance was optimal for the bare-handed operator.

  19. KSC-08pd3887

    NASA Image and Video Library

    2008-11-30

    EDWARDS, Calif. – Against a setting sun, space shuttle Endeavour undergoes recovery operations on Edwards Air Force Base in California after its landing. The orbiter convoy normally begins recovery operations in earnest about two hours before the shuttle is scheduled to land. Specially designed vehicles or units and a team of trained personnel “safe” the orbiter and prepare it for towing. Purge and Coolant Umbilical Access Vehicles are moved into position behind the orbiter to get access to the umbilical areas. The flight crew is replaced aboard the orbiter by exchange sup¬port personnel who prepare the orbiter for ground tow operations, install switch guards and remove data packages from any onboard experiments. After a total safety downgrade, vehicle ground personnel make numerous preparations for the towing operation, including install¬ing landing gear lock pins, disconnecting the nose landing gear drag link, positioning the towing vehicle in front of the orbiter and connecting the tow bar. The decision to land Endeavour at Edwards was made due to weather concerns at NASA's Kennedy Space Center in Florida. In the 52nd landing at Edwards, Endeavour touched down at 4:25 p.m. EST to end the STS-126 mission, completing its 16-day journey of more than 6.6 million miles in space. Endeavour will be returned to Kennedy atop a Shuttle Carrier Aircraft, or SCA, a modified Boeing 747 jetliner. Photo credit: NASA/Tony Landis, VAFB

  20. KSC-08pd3888

    NASA Image and Video Library

    2008-11-30

    EDWARDS, Calif. – Against a setting sun, space shuttle Endeavour undergoes recovery operations on Edwards Air Force Base in California after its landing. The orbiter convoy normally begins recovery operations in earnest about two hours before the shuttle is scheduled to land. Specially designed vehicles or units and a team of trained personnel “safe” the orbiter and prepare it for towing. Purge and Coolant Umbilical Access Vehicles are moved into position behind the orbiter to get access to the umbilical areas. The flight crew is replaced aboard the orbiter by exchange sup¬port personnel who prepare the orbiter for ground tow operations, install switch guards and remove data packages from any onboard experiments. After a total safety downgrade, vehicle ground personnel make numerous preparations for the towing operation, including install¬ing landing gear lock pins, disconnecting the nose landing gear drag link, positioning the towing vehicle in front of the orbiter and connecting the tow bar. The decision to land Endeavour at Edwards was made due to weather concerns at NASA's Kennedy Space Center in Florida. In the 52nd landing at Edwards, Endeavour touched down at 4:25 p.m. EST to end the STS-126 mission, completing its 16-day journey of more than 6.6 million miles in space. Endeavour will be returned to Kennedy atop a Shuttle Carrier Aircraft, or SCA, a modified Boeing 747 jetliner. Photo credit: NASA/Tony Landis, VAFB

  1. KSC-08pd3885

    NASA Image and Video Library

    2008-11-30

    EDWARDS, Calif. – On Edwards Air Force Base in California, space shuttle Endeavour undergoes recovery operations after its landing. The orbiter convoy normally begins recovery operations in earnest about two hours before the shuttle is scheduled to land. Specially designed vehicles or units and a team of trained personnel “safe” the orbiter and prepare it for towing. Purge and Coolant Umbilical Access Vehicles are moved into position behind the orbiter to get access to the umbilical areas. The flight crew is replaced aboard the orbiter by exchange sup¬port personnel who prepare the orbiter for ground tow operations, install switch guards and remove data packages from any onboard experiments. After a total safety downgrade, vehicle ground personnel make numerous preparations for the towing operation, including install¬ing landing gear lock pins, disconnecting the nose landing gear drag link, positioning the towing vehicle in front of the orbiter and connecting the tow bar. The decision to land Endeavour at Edwards was made due to weather concerns at NASA's Kennedy Space Center in Florida. In the 52nd landing at Edwards, Endeavour touched down at 4:25 p.m. EST to end the STS-126 mission, completing its 16-day journey of more than 6.6 million miles in space. Endeavour will be returned to Kennedy atop a Shuttle Carrier Aircraft, or SCA, a modified Boeing 747 jetliner. Photo credit: NASA/Tony Landis, VAFB

  2. KSC-08pd3886

    NASA Image and Video Library

    2008-11-30

    EDWARDS, Calif. – On Edwards Air Force Base in California, space shuttle Endeavour undergoes recovery operations after its landing. The orbiter convoy normally begins recovery operations in earnest about two hours before the shuttle is scheduled to land. Specially designed vehicles or units and a team of trained personnel “safe” the orbiter and prepare it for towing. Purge and Coolant Umbilical Access Vehicles are moved into position behind the orbiter to get access to the umbilical areas. The flight crew is replaced aboard the orbiter by exchange sup¬port personnel who prepare the orbiter for ground tow operations, install switch guards and remove data packages from any onboard experiments. After a total safety downgrade, vehicle ground personnel make numerous preparations for the towing operation, including install¬ing landing gear lock pins, disconnecting the nose landing gear drag link, positioning the towing vehicle in front of the orbiter and connecting the tow bar. The decision to land Endeavour at Edwards was made due to weather concerns at NASA's Kennedy Space Center in Florida. In the 52nd landing at Edwards, Endeavour touched down at 4:25 p.m. EST to end the STS-126 mission, completing its 16-day journey of more than 6.6 million miles in space. Endeavour will be returned to Kennedy atop a Shuttle Carrier Aircraft, or SCA, a modified Boeing 747 jetliner. Photo credit: NASA/Tony Landis, VAFB

  3. 40 CFR 190.10 - Standards for normal operations.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 25 2014-07-01 2014-07-01 false Standards for normal operations. 190.10 Section 190.10 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) RADIATION PROTECTION PROGRAMS ENVIRONMENTAL RADIATION PROTECTION STANDARDS FOR NUCLEAR POWER OPERATIONS Environmental...

  4. 40 CFR 190.10 - Standards for normal operations.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 26 2012-07-01 2011-07-01 true Standards for normal operations. 190.10 Section 190.10 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) RADIATION PROTECTION PROGRAMS ENVIRONMENTAL RADIATION PROTECTION STANDARDS FOR NUCLEAR POWER OPERATIONS Environmental Standards...

  5. Remote Navigation for Complex Arrhythmia

    PubMed Central

    Suman-Horduna, Irina; Babu-Narayan, Sonya V; Ernst, Sabine

    2013-01-01

    Magnetic navigation has been established as an alternative to conventional, manual catheter navigation for invasive electrophysiology interventions about a decade ago. Besides the obvious advantage of radiation protection for the operator who is positioned remotely from the patient, there are additional benefits of steering the tip of a very floppy catheter. This manuscript reviews the published evidence from simple arrhythmias in patients with normal cardiac anatomy to the most complex congenital heart disease. This progress was made possible by the introduction of improved catheters and most importantly irrigated-tip electrodes. PMID:26835041

  6. Automatic development of normal zone in composite MgB2/CuNi wires with different diameters

    NASA Astrophysics Data System (ADS)

    Jokinen, A.; Kajikawa, K.; Takahashi, M.; Okada, M.

    2010-06-01

    One of the promising applications with superconducting technology for hydrogen utilization is a sensor with a magnesium-diboride (MgB2) superconductor to detect the position of boundary between the liquid hydrogen and the evaporated gas stored in a Dewar vessel. In our previous experiment for the level sensor, the normal zone has been automatically developed and therefore any energy input with the heater has not been required for normal operation. Although the physical mechanism for such a property of the MgB2 wire has not been clarified yet, the deliberate application might lead to the realization of a simpler superconducting level sensor without heater system. In the present study, the automatic development of normal zone with increasing a transport current is evaluated for samples consisting of three kinds of MgB2 wires with CuNi sheath and different diameters immersed in liquid helium. The influences of the repeats of current excitation and heat cycle on the normal zone development are discussed experimentally. The aim of this paper is to confirm the suitability of MgB2 wire in a heater free level sensor application. This could lead to even more optimized design of the liquid hydrogen level sensor and the removal of extra heater input.

  7. Use of a position-sensitive multi-anode photomultiplier tube for finding gamma-ray source direction

    NASA Astrophysics Data System (ADS)

    Mukhopadhyay, Sanjoy; Maurer, Richard; Guss, Paul

    2014-09-01

    Organizations that fail to use known near-miss data when making operational decisions may be inadvertently rewarding risky behavior. Over time such risk taking compounds as similar near-misses are repeatedly observed and the ability to recognize anomalies and document the events decreases (i.e., normalization of deviance [1,2,3]). History from the space shuttle program shows that only the occasional large failure increases attention to anomalies again. This paper discusses prescriptions for project managers based on several on-going activities at NASA Goddard Space Flight Center (GSFC) to improve the lesson learning process for space missions. We discuss how these efforts can contribute to reducing near-miss bias and the normalization of deviance. This research should help organizations design learning processes that draw lessons from near-misses.

  8. Intraoperative visible bubbling of air may be the first sign of venous air embolism during posterior surgery for scoliosis.

    PubMed

    Wills, John; Schwend, Richard M; Paterson, Andrew; Albin, Maurice S

    2005-10-15

    Case report of two children sustaining venous air embolism (VAE) during posterior surgery for scoliosis. To report 2 cases where visible bubbling at the operative site was the first clinical indication of VAE-induced cardiovascular collapse and to raise the level of consciousness that VAE in the prone position can occur, often with serious consequences. Twenty-two cases of VAE during surgery for scoliosis in the prone position have been reported. Ten were fatal and ten were in children. Visible bubbling at the operative site was noted in two published cases. Retrospective study of 2 cases of VAE at one institution. Clinical, anesthetic, and radiographic features are presented. Details of previously published cases are reviewed and discussed. Both patients were girls with adolescent scoliosis who underwent prone positioned posterior spinal fusion with instrumentation. Visible bubbling of air at the thoracic aspect of the surgical site was noted near the completion of instrumentation and was the first indication of VAE. In both cases, this was clinically recognized and promptly treated. One patient survived normally and the other died. Visible air bubbling at the operative site may herald the onset of massive VAE during multilevel posterior spinal fusion and instrumentation. A prospective multicenter study using precordial Doppler, central venous catheter, and end-tidal CO2 is recommended to determine the true incidence of VAE in spinal deformity surgery and to evaluate monitoring and treatment methods.

  9. Chimney for enhancing flow of coolant water in natural circulation boiling water reactor

    DOEpatents

    Oosterkamp, W.J.; Marquino, W.

    1999-01-05

    A chimney which can be reconfigured or removed during refueling to allow vertical removal of the fuel assemblies is disclosed. The chimney is designed to be collapsed or dismantled. Collapse or dismantlement of the chimney reduces the volume required for chimney storage during the refueling operation. Alternatively, the chimney has movable parts which allow reconfiguration of its structure. In a first configuration suitable for normal reactor operation, the chimney is radially constricted such that the chimney obstructs vertical removal of the fuel assemblies. In a second configuration suitable for refueling or maintenance of the fuel core, the parts of the chimney which obstruct access to the fuel assemblies are moved radially outward to positions whereas access to the fuel assemblies is not obstructed. 11 figs.

  10. Tubing and cable cutting tool

    NASA Technical Reports Server (NTRS)

    Mcsmith, D. D.; Richardson, J. I. (Inventor)

    1984-01-01

    A hand held hydraulic cutting tool was developed which is particularly useful in deactivating ejection seats in military aircraft rescue operations. The tool consists primarily of a hydraulic system composed of a fluid reservoir, a pumping piston, and an actuator piston. Mechanical cutting jaws are attached to the actuator piston rod. The hydraulic system is controlled by a pump handle. As the pump handle is operated the actuator piston rod is forced outward and thus the cutting jaws are forced together. The frame of the device is a flexible metal tubing which permits easy positioning of the tool cutting jaws in remote and normally inaccessible locations. Bifurcated cutting edges ensure removal of a section of the tubing or cable to thereby reduce the possibility of accidental reactivation of the tubing or cable being severed.

  11. Restricted numerical range: A versatile tool in the theory of quantum information

    NASA Astrophysics Data System (ADS)

    Gawron, Piotr; Puchała, Zbigniew; Miszczak, Jarosław Adam; Skowronek, Łukasz; Życzkowski, Karol

    2010-10-01

    Numerical range of a Hermitian operator X is defined as the set of all possible expectation values of this observable among a normalized quantum state. We analyze a modification of this definition in which the expectation value is taken among a certain subset of the set of all quantum states. One considers, for instance, the set of real states, the set of product states, separable states, or the set of maximally entangled states. We show exemplary applications of these algebraic tools in the theory of quantum information: analysis of k-positive maps and entanglement witnesses, as well as study of the minimal output entropy of a quantum channel. Product numerical range of a unitary operator is used to solve the problem of local distinguishability of a family of two unitary gates.

  12. Urine Kidney Injury Molecule-1: A Potential Non-invasive Biomarker for Patients with Renal Cell Carcinoma

    PubMed Central

    Zhang, Ping L.; Mashni, Joseph W.; Sabbisetti, Venkata S.; Schworer, Charles M.; Wilson, George D.; Wolforth, Stacy C.; Kernen, Kenneth M.; Seifman, Brian D.; Amin, Mitual B.; Geddes, Timothy J.; Lin, Fan; Bonventre, Joseph V.; Hafron, Jason M.

    2014-01-01

    Objective To evaluate the use of urine KIM-1 as a biomarker for supporting a diagnosis of kidney cancers before operation. Methods A total of 19 patients were enrolled in the study based on preoperative imaging studies. Pre-operative and follow-up (1 month) uKIM-1 levels were measured and normalized with uCr levels and renal tumors were stained for KIM-1 using immunohistochemical techniques. Results The percentage of KIM-1 positive staining RCC cells ranged from 10 to 100% and the staining intensity ranged from 1+ to 3+. Based on the KIM-1 staining, 19 cases were divided into the KIM-1-negative staining group (n =7) and the KIM-1-positive group (n = 12). Serum creatinine (sCR) levels were significantly elevated after nephrectomy in both groups. In the KIM-1 negative group, uKIM-1/uCr remained at a similar level before (0.37 ± 0.1 ng/mg Cr) and after nephrectomy (0.32 ± 0.01 ng/mg Cr). However, in the KIM-1 positive group, elevated uKIM-1/uCr at 1.20 ± 0.31 ng/mg Cr was significantly reduced to 0.36± 0.1 ng/mg Cr, which was similar to the pre-operative uKIM-1/uCr (0.37 ± 0.1 ng/mg Cr) in the KIM-1 negative group. Conclusion Our study showed significant reduction in uKIM-1/uCr after nephrectomy, suggesting that urine KIM-1 may serve as a surrogate biomarker for kidney cancer and a non-invasive pre-operative measure to evaluate the malignant potential of renal masses. PMID:23979814

  13. Generalized Friedland's theorem for C0-semigroups

    NASA Astrophysics Data System (ADS)

    Cichon, Dariusz; Jung, Il Bong; Stochel, Jan

    2008-07-01

    Friedland's characterization of bounded normal operators is shown to hold for infinitesimal generators of C0-semigroups. New criteria for normality of bounded operators are furnished in terms of Hamburger moment problem. All this is achieved with the help of the celebrated Ando's theorem on paranormal operators.

  14. 40 CFR 190.10 - Standards for normal operations.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Standards for the Uranium Fuel Cycle § 190.10 Standards for normal operations. Operations covered by this... radioactive materials, radon and its daughters excepted, to the general environment from uranium fuel cycle... the general environment from the entire uranium fuel cycle, per gigawatt-year of electrical energy...

  15. Effects of the 2011 Tohoku Earthquake on VLBI Geode- tic Measurements

    NASA Astrophysics Data System (ADS)

    MacMillan, D.; Behrend, D.; Kurihara, S.

    2012-12-01

    The VLBI antenna TSUKUB32 at Tsukuba, Japan observes in 24-hour observing sessions once per week with the R1 operational network and on additional days with other networks on a more irregular basis. Further, the antenna is an endpoint of the single-baseline, 1-hr Intensive Int2 sessions observed on the weekends for the determination of UT1. TSUKUB32 returned to normal operational observing one month after the earthquake. The antenna is 160 km west and 240 km south of the epicenter of the Tohoku earthquake. We looked at the transient behavior of the TSUKUB32 position time series following the earthquake and found that significant deformation is continuing. The eastward rate relative to the long-term rate prior to the earthquake was about 20 cm/yr four months after the earthquake and 9 cm/yr after one year. The VLBI series agrees closely with the corresponding JPL (Jet Propulsion Laboratory) GPS series measured by the co-located GPS antenna TSUK. The co-seismic UEN displacement at Tsukuba as determined by VLBI was (-90 mm, 640 mm, 44 mm). We examined the effect of the variation of the TSUKUB32 position on EOP estimates and then used the GPS data to correct its position for the estimation of UT1 in the Tsukuba-Wettzell Int2 Intensive experiments. For this purpose and to provide operational UT1, the IVS scheduled a series of weekend Intensive sessions observing on the Kokee-Wettzell baseline immediately before each of the two Tsukuba-Wettzell Intensive sessions. Comparisons between the UT1 estimates from these weekend sessions and the USNO (United States Naval Observatory) combination series were used to validate the GPS correction to the TSUKUB32 position.

  16. Tele-operated search robot for human detection using histogram of oriented objects

    NASA Astrophysics Data System (ADS)

    Cruz, Febus Reidj G.; Avendaño, Glenn O.; Manlises, Cyrel O.; Avellanosa, James Jason G.; Abina, Jyacinth Camille F.; Masaquel, Albert M.; Siapno, Michael Lance O.; Chung, Wen-Yaw

    2017-02-01

    Disasters such as typhoons, tornadoes, and earthquakes are inevitable. Aftermaths of these disasters include the missing people. Using robots with human detection capabilities to locate the missing people, can dramatically reduce the harm and risk to those who work in such circumstances. This study aims to: design and build a tele-operated robot; implement in MATLAB an algorithm for the detection of humans; and create a database of human identification based on various positions, angles, light intensity, as well as distances from which humans will be identified. Different light intensities were made by using Photoshop to simulate smoke, dust and water drops conditions. After processing the image, the system can indicate either a human is detected or not detected. Testing with bodies covered was also conducted to test the algorithm's robustness. Based on the results, the algorithm can detect humans with full body shown. For upright and lying positions, detection can happen from 8 feet to 20 feet. For sitting position, detection can happen from 2 feet to 20 feet with slight variances in results because of different lighting conditions. The distances greater than 20 feet, no humans can be processed or false negatives can occur. For bodies covered, the algorithm can detect humans in cases made under given circumstances. On three positions, humans can be detected from 0 degrees to 180 degrees under normal, with smoke, with dust, and with water droplet conditions. This study was able to design and build a tele-operated robot with MATLAB algorithm that can detect humans with an overall precision of 88.30%, from which a database was created for human identification based on various conditions, where humans will be identified.

  17. [Identification and management of intra-operative suspicious tissues in 20 transsphenoidal surgery cases].

    PubMed

    Liu, Jun-Feng; Ke, Chang-Shu; Chen, Xi; Xu, Yu; Zhang, Hua-Qiu; Chen, Juan; Gan, Chao; Li, Chao-Xi; Lei, Ting

    2013-05-01

    To determine appropriate protocols for the identification and management of intra operative suspicious tissues during transsphenoidal surgery. Clinical data and pathological reports of 20 patients with intra-operative suspicious tissues during transsphenoidal surgeries were analyzed retrospectively. The methods for discriminating between adenoma and normal pituitary tissues were reviewed. The postoperative pathological reports revealed that adenoma and normal pituitary tissues coexisted in 9 samples, while 5 samples were identified as normal pituitary tissues, 2 as adenoma tissues, and 4 as other tissues. Adenomas were distinguished from normal pituitary tissues on the basis of intra-operative appearance, texture, blood supply and possible existence of boundary. If decisions are difficult to made during surgeries from the appearance of the suspicious tissues, pathological examinations are advised as a guidance for the next steps.

  18. Reengineering Electronic Fetal Monitoring Interpretation: Using the Fetal Reserve Index to Anticipate the Need for Emergent Operative Delivery.

    PubMed

    Eden, Robert D; Evans, Mark I; Evans, Shara M; Schifrin, Barry S

    2018-04-01

    The near-ubiquitous use of electronic fetal monitoring has failed to lower the rates of both cerebral palsy and emergency operative deliveries (EODs). Its performance metrics have low sensitivity, specificity, and predictive values for both. There are many EODs, but the vast majority have normal outcomes. The EODs, however, cause serious disruption in the delivery suite routine with increased complications, anxiety, and concern for all. We developed the fetal reserve index (FRI) as multicomponent algorithm including 4 FHR components (analyzed individually), uterine activity, and maternal, obstetrical, and fetal risk factors to assess risk of cerebral palsy and EOD. Scores were categorized into green, yellow, and red zones. Here, we studied 300 patients by the FRI, all of whom had normal neonatal outcomes. We attempted to distinguish the clinical course of those cases which required an EOD versus controls which did not. 51 cases with EOD had FRIs much lower than 249 non-EOD cases. The red zone was reached more frequently ( P < .001) and lasted longer (1.06 vs 0.05 hours; P < .001). Reaching the red zone had a sensitivity of 92% for EOD, with a positive predictive value of 64% and a false positive rate of 10.4%. Our data suggest the FRI can significantly lower the incidence of EODs by identifying the opportunity for intrauterine resuscitation. Our approach can reduce the disruptive effects of EODs and their concomitant increased risks of complications. The FRI may provide a metric that can refine labor management to reduce CP and EODs.

  19. CD117 expression in operable oesophageal squamous cell carcinomas predicts worse clinical outcome

    PubMed Central

    Fan, Huijie; Yuan, Yuan; Wang, Junsheng; Zhou, Fuyou; Zhang, Mingzhi; Giercksky, Karl-Erik; Nesland, Jahn M; Suo, Zhenhe

    2013-01-01

    Aims To investigate the aberrant expression of CD117 in oesophageal squamous cell carcinoma (SCC) and its prognostic significance. Methods and results Immunohistochemical staining for CD117 was performed on tissue microarray and routine tissue sections from 157 oesophageal SCC patients and 10 normal oesophageal epithelia adjacent to tumour. The positive rate of CD117 expression was 29.9% in oesophageal SCC tissues, whereas no CD117 expression was detected in the 10 normal oesophageal epithelia. CD117 expression was significantly associated with T stage (P < 0.001), distant metastasis (P = 0.015), lymph node metastasis (P = 0.019), and clinical stage (P = 0.021). Progression-free survival in the patients with CD117-positive tumours was shorter than that in the patients with CD117-negative tumours (P = 0.010). In univariate analyses, CD117 expression was the most significant factor for overall survival of oesophageal SCC patients (P < 0.001), followed by lymph node metastasis (P = 0.001), T stage (P = 0.002), clinical stage (P = 0.006), distant metastasis (P = 0.020), and histological grade (P = 0.027). Multivariate analyses verified that CD117 expression was an independent prognostic marker for oesophageal SCC patients (P = 0.002). In addition, CD117 expression predicted poorer survival in patients without distant metastases. Conclusions CD117 expression in operable oesophageal SCC may be a valuable prognostic marker, and detection of its expression in clinical samples may be useful in defining a subclass of oesophageal SCCs with extremely poor clinical outcome, which may require a specially targeted treatment modality. PMID:23570416

  20. A likelihood ratio anomaly detector for identifying within-perimeter computer network attacks

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Grana, Justin; Wolpert, David; Neil, Joshua

    The rapid detection of attackers within firewalls of enterprise computer networks is of paramount importance. Anomaly detectors address this problem by quantifying deviations from baseline statistical models of normal network behavior and signaling an intrusion when the observed data deviates significantly from the baseline model. But, many anomaly detectors do not take into account plausible attacker behavior. As a result, anomaly detectors are prone to a large number of false positives due to unusual but benign activity. Our paper first introduces a stochastic model of attacker behavior which is motivated by real world attacker traversal. Then, we develop a likelihoodmore » ratio detector that compares the probability of observed network behavior under normal conditions against the case when an attacker has possibly compromised a subset of hosts within the network. Since the likelihood ratio detector requires integrating over the time each host becomes compromised, we illustrate how to use Monte Carlo methods to compute the requisite integral. We then present Receiver Operating Characteristic (ROC) curves for various network parameterizations that show for any rate of true positives, the rate of false positives for the likelihood ratio detector is no higher than that of a simple anomaly detector and is often lower. Finally, we demonstrate the superiority of the proposed likelihood ratio detector when the network topologies and parameterizations are extracted from real-world networks.« less

  1. A likelihood ratio anomaly detector for identifying within-perimeter computer network attacks

    DOE PAGES

    Grana, Justin; Wolpert, David; Neil, Joshua; ...

    2016-03-11

    The rapid detection of attackers within firewalls of enterprise computer networks is of paramount importance. Anomaly detectors address this problem by quantifying deviations from baseline statistical models of normal network behavior and signaling an intrusion when the observed data deviates significantly from the baseline model. But, many anomaly detectors do not take into account plausible attacker behavior. As a result, anomaly detectors are prone to a large number of false positives due to unusual but benign activity. Our paper first introduces a stochastic model of attacker behavior which is motivated by real world attacker traversal. Then, we develop a likelihoodmore » ratio detector that compares the probability of observed network behavior under normal conditions against the case when an attacker has possibly compromised a subset of hosts within the network. Since the likelihood ratio detector requires integrating over the time each host becomes compromised, we illustrate how to use Monte Carlo methods to compute the requisite integral. We then present Receiver Operating Characteristic (ROC) curves for various network parameterizations that show for any rate of true positives, the rate of false positives for the likelihood ratio detector is no higher than that of a simple anomaly detector and is often lower. Finally, we demonstrate the superiority of the proposed likelihood ratio detector when the network topologies and parameterizations are extracted from real-world networks.« less

  2. Assessment of Knee Proprioception in the Anterior Cruciate Ligament Injury Risk Position in Healthy Subjects: A Cross-sectional Study.

    PubMed

    Mir, Seyed Mohsen; Talebian, Saeed; Naseri, Nasrin; Hadian, Mohammad-Reza

    2014-10-01

    [Purpose] Knee joint proprioception combines sensory input from a variety of afferent receptors that encompasses the sensations of joint position and motion. Poor proprioception is one of the risk factors of anterior cruciate ligament injury. Most studies have favored testing knee joint position sense in the sagittal plane and non-weight-bearing position. One of the most common mechanisms of noncontact anterior cruciate ligament injury is dynamic knee valgus. No study has measured joint position sense in a manner relevant to the mechanism of injury. Therefore, the aim of this study was to measure knee joint position sense in the noncontact anterior cruciate ligament injury risk position and normal condition. [Subjects and Methods] Thirty healthy male athletes participated in the study. Joint position sense was evaluated by active reproduction of the anterior cruciate ligament injury risk position and normal condition. The dominant knees of subjects were tested. [Results] The results showed less accurate knee joint position sense in the noncontact anterior cruciate ligament injury risk position rather than the normal condition. [Conclusion] The poorer joint position sense in non-contact anterior cruciate ligament injury risk position compared with the normal condition may contribute to the increased incidence of anterior cruciate ligament injury.

  3. Texture analysis applied to second harmonic generation image data for ovarian cancer classification

    NASA Astrophysics Data System (ADS)

    Wen, Bruce L.; Brewer, Molly A.; Nadiarnykh, Oleg; Hocker, James; Singh, Vikas; Mackie, Thomas R.; Campagnola, Paul J.

    2014-09-01

    Remodeling of the extracellular matrix has been implicated in ovarian cancer. To quantitate the remodeling, we implement a form of texture analysis to delineate the collagen fibrillar morphology observed in second harmonic generation microscopy images of human normal and high grade malignant ovarian tissues. In the learning stage, a dictionary of "textons"-frequently occurring texture features that are identified by measuring the image response to a filter bank of various shapes, sizes, and orientations-is created. By calculating a representative model based on the texton distribution for each tissue type using a training set of respective second harmonic generation images, we then perform classification between images of normal and high grade malignant ovarian tissues. By optimizing the number of textons and nearest neighbors, we achieved classification accuracy up to 97% based on the area under receiver operating characteristic curves (true positives versus false positives). The local analysis algorithm is a more general method to probe rapidly changing fibrillar morphologies than global analyses such as FFT. It is also more versatile than other texture approaches as the filter bank can be highly tailored to specific applications (e.g., different disease states) by creating customized libraries based on common image features.

  4. 30 CFR 800.23 - Self-bonding.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... normal operating cycle of the business. Current liabilities means obligations which are reasonably expected to be paid or liquidated within one year or within the normal operating cycle of the business... applicant has been in continuous operation as a business entity for a period of not less than 5 years...

  5. 14 CFR 171.271 - Installation requirements.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... generated. Adequate power capacity must be provided for the operation of test and working equipment of the... restoration of power, the batteries must be restored to full charge within 24 hours. When primary power is... battery must permit continuation of normal operation for at least two hours under the normal operating...

  6. Correct Hox gene expression established independently of position in Caenorhabditis elegans.

    PubMed

    Cowing, D; Kenyon, C

    1996-07-25

    The Hox genes are expressed in a conserved sequence of spatial domains along the anteroposterior (A/P) body axes of many organisms. In Drosophila, position-specific signals located along the A/P axis establish the pattern of Hox gene expression. In the nematode Caenorhabditis elegans, it is not known how the pattern of Hox gene expression is established. C. elegans uses lineal control mechanisms and local cell interactions to specify early blastomere identities. However, many cells expressing the same Hox gene are unrelated by lineage, suggesting that, as in Drosophila, domains of Hox gene expression may be defined by cell-extrinsic A/P positional signals. To test this, we have investigated whether posterior mesodermal and ectodermal cells will express their normal posterior Hox gene when they are mispositioned in the anterior. Surprisingly, we find that correct Hox gene expression does not depend on cell position, but is highly correlated with cell lineage. Thus, although the most striking feature of Hox gene expression is its positional specificity, in C. elegans the pattern is achieved, at least in part, by a lineage-specific control system that operates without regard to A/P position.

  7. Sub-Network Access Control Technology Demonstrator: Software Design of the Network Management System

    DTIC Science & Technology

    2002-08-01

    Canadian Operational Fleet. Requirements The proposed network management solution must provide the normal monitoring and configuration mechanisms generally...Joint Warrior Inter- operability Demonstrations (JWID) m and the Communication System Network Inter- Operability (CSNI) Navy Network Trials. In short...management functional area normally includes two main functions: fault isolation and diagnosis, and restoration of the system . In short, an operator

  8. Diagnostic Performance of Ultrasonography for Pediatric Appendicitis: A Night and Day Difference?

    PubMed

    Mangona, Kate Louise M; Guillerman, R Paul; Mangona, Victor S; Carpenter, Jennifer; Zhang, Wei; Lopez, Monica; Orth, Robert C

    2017-12-01

    For imaging pediatric appendicitis, ultrasonography (US) is preferred because of its lack of ionizing radiation, but is limited by operator dependence. This study investigates the US diagnostic performance during night shifts covered by radiology trainees compared to day shifts covered by attending radiologists. Appy-Scores (1 = completely visualized normal appendix; 2 = partially visualized normal appendix; 3 = nonvisualized appendix with no inflammatory changes in the expected region of the appendix; 4 = equivocal; 5a = nonperforated appendicitis; 5b = perforated appendicitis) from 2935 US examinations (2161:774, day-to-night) from July 2013 to 2014 were correlated with the intraoperative diagnoses and the clinical follow-up. The diagnostic performance of trainees and attendings was compared with Fisher exact test. Interobserver agreement was measured by Cohen kappa coefficient. Appendicitis prevalence was 25.3% (day) and 22.5% (night). Sensitivity, specificity, accuracy, negative predictive value, and positive predictive vale were 94.0%, 93.7%, 93.8%, 97.9%, and 83.4% during the day and 92.0%, 91.2%, 91.3%, 97.5%, and 75.2% at night. Specificity (P = .048) and positive predictive value (P = .011) differed, with more false positives at night (7%) than during the day (4.7%). Trainee and attending agreement was high (k = 0.995), with Appy-Scores of 1, 4, and 5a most frequently discordant. US has a high diagnostic performance and interobserver agreement for pediatric appendicitis when interpreted by radiology trainees during night shifts or attending radiologists during day shifts. However, lower specificity and positive predictive value at night warrants a thorough trainee education to avoid false-positive examinations. Published by Elsevier Inc.

  9. Cardiovascular Adjustments to Gravitational Stress

    NASA Technical Reports Server (NTRS)

    Blomqvist, C. Gunnar; Stone, H. Lowell

    1991-01-01

    The effects of gravity on the cardiovascular system must be taken into account whenever a hemodynamic assessment is made. All intravascular pressure have a gravity-dependent hydrostatic component. The interaction between the gravitational field, the position of the body, and the functional characteristics of the blood vessels determines the distribution of intravascular volume. In turn this distribution largely determines cardiac pump function. Multiple control mechanisms are activated to preserve optimal tissue perfusion when the magnitude of the gravitational field or its direction relative to the body changes. Humans are particularly sensitive to such changes because of the combination of their normally erect posture and the large body mass and blood volume below the level of the heart. Current aerospace technology also exposes human subjects to extreme variations in the gravitational forces that range from zero during space travel to as much an nine-times normal during operation of high-performance military aircraft. This chapter therefore emphasizes human physiology.

  10. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kim, C; Seduk, J; Yang, T

    Purpose: A prototype actives scanning beam delivery system was designed, manufactured and installed as a part of the Korea Heavy Ion Medical Accelerator Project. The prototype system includes the most components for steering, modulating, detecting incident beam to patient. The system was installed in MC-50 cyclotron beam line and tested to extract the normal operation conditions. Methods: The commissioning process was completed by using 45 MeV of proton beam. To measure the beam position accuracy along the scanning magnet power supply current, 25 different spots were scanning and measured. The scanning results on GaF film were compared with the irradiationmore » plan. Also, the beam size variation and the intensity reduction using range shifter were measured and analyzed. The results will be used for creating a conversion factors for asymmetric behavior of scanning magnets and a dose compensation factor for longitudinal direction. Results: The results show asymmetry operations on both scanning × and y magnet. In case of scanning magnet × operation, the current to position conversion factors were measured 1.69 mm/A for positive direction and 1.74 mm/A for negative direction. The scanning magnet y operation shows 1.38mm/A and 1.48 mm/A for both directions. The size of incoming beam which was 18 mm as sigma becomes larger up to 55 mm as sigma while using 10 mm of the range shifter plate. As the beam size becomes large, the maximum intensity of the was decreased. In case of using 10 mm of range shifter, the maximum intensity was only 52% compared with no range shifter insertion. Conclusion: For the appropriate operation of the prototype active scanning system, the commissioning process were performed to measure the beam characteristics variation. The obtained results would be applied on the irradiation planning software for more precise dose delivery using the active scanning system.« less

  11. Valve

    DOEpatents

    Cho, Nakwon

    1980-01-01

    A positive acting valve suitable for operation in a corrosive environment is provided. The valve includes a hollow valve body defining an open-ended bore for receiving two, axially aligned, spaced-apart, cylindrical inserts. One insert, designated the seat insert, terminates inside the valve body in an annular face which lies within plane normal to the axis of the two inserts. An elastomeric O-ring seal is disposed in a groove extending about the annular face. The other insert, designated the wedge insert, terminates inside the valve body in at least two surfaces oppositely inclined with respect to each other and with respect to a plane normal to the axis of the two inserts. An elongated reciprocable gate, movable between the two inserts along a path normal to the axis of the two inserts, has a first flat face portion disposed adjacent and parallel to the annular face of the seat insert. The gate has a second face portion opposite to the first face portion provided with at least two oppositely inclined surfaces for mating with respective inclined surfaces of the wedge insert. An opening is provided through the gate which registers with a flow passage through the two inserts when the valve is open. Interaction of the respective inclined surfaces of the gate and wedge insert act to force the first flat face portion of the gate against the O-ring seal in the seat insert at the limits of gate displacement where it reaches its respective fully open and fully closed positions.

  12. Effect of Reverse Bias Stress on Leakage Currents and Breakdown Voltages of Solid Tantalum Capacitors

    NASA Technical Reports Server (NTRS)

    Teverovsky, Alexander A.

    2011-01-01

    The majority of solid tantalum capacitors are produced by high-temperature sintering of a fine tantalum powder around a tantalum wire followed by electrolytic anodization that forms a thin amorphous Ta2O5 dielectric layer and pyrolysis of manganese nitrite on the oxide to create a conductive manganese dioxide electrode. A contact to tantalum wire is used as anode terminal and to the manganese layer as a cathode terminal of the device. This process results in formation of an asymmetric Ta -- Ta2O5 -- MnO2 capacitor that has different characteristics at forward (positive bias applied to tantalum) and reverse (positive bias applied to manganese cathode) voltages. Reverse bias currents might be several orders of magnitude larger than forward leakage currents so I-V characteristics of tantalum capacitors resemble characteristics of semiconductor rectifiers. Asymmetric I-V characteristics of Ta -- anodic Ta2O5 systems have been observed at different top electrode materials including metals, electrolytes, conductive polymers, and manganese oxide thus indicating that this phenomenon is likely related to the specifics of the Ta -- Ta2O5 interface. There have been multiple attempts to explain rectifying characteristics of capacitors employing anodic tantalum pentoxide dielectrics. A brief review of works related to reverse bias (RB) behavior of tantalum capacitors shows that the mechanism of conduction in Ta -- Ta2O5 systems is still not clear and more testing and analysis is necessary to understand the processes involved. If tantalum capacitors behave just as rectifiers, then the assessment of the safe reverse bias operating conditions would be a relatively simple task. Unfortunately, these parts can degrade with time under reverse bias significantly, and this further complicates analysis of the I-V characteristics and establishing safe operating areas of the parts. On other hand, time dependence of reverse currents might provide additional information for investigation of the processes under reverse bias conditions. In practice, there were instances when, due to unforeseen events, the system operated at conditions when capacitors experience periodically a relatively small reverse bias for some time followed by normal, forward bias conditions. In such a case an assessment should be made on the degree to which these capacitors are degraded by application of low-voltage reverse bias, and whether this degradation can be reversed by normal operating conditions. In this study, reverse currents in different types of tantalum capacitors were monitored at different reverse voltages below 15%VR and temperatures in the range from room to 145 C for up to 150 hours to get better understanding of the degradation process and determine conditions favorable to the unstable mode of operation. The reversibility of RB degradation has been evaluated after operation of the capacitors at forward bias conditions. The effect of reverse bias stress (RBS) on reliability at normal operating conditions was evaluated using highly accelerated life testing at voltages of 1.5VR and 2 VR and by analysis of changes in distributions of breakdown voltages. Possible mechanisms of RB degradation are discussed.

  13. Therapeutic experience of severe and recurrent secondary hyperparathyroidism in a patient on hemodialysis for 18 years: A case report.

    PubMed

    Zhu, Mingwen; Zhang, Zongming; Lin, Fangcai; Miao, Jieping; Wang, Pei; Zhang, Chong; Yu, Hongwei; Deng, Hai; Liu, Zhuo; Liu, Limin; Wan, Baijiang; Yang, Haiyan; Song, Mengmeng; Zhao, Yue; Jiang, Nan; Zhang, Zichao; Zhang, Zhenya; Pan, Lijie

    2018-05-01

    For patients with refractory secondary hyperparathyroidism (SHPT), parathyroidectomy (PTX) has received increasing attention. However, evidence-based medicine shows that there is still controversy regarding surgical methods, efficacy, and safety. We retrospectively analyzed the process of diagnosis and treatment in one patient with severe SHPT and long-term chronic renal failure (CRF), so as to further improve the therapeutic effect. A 61-year-old female with SHPT and CRF manifested as no urine for 18 years, underwent PTX 4 times since September 2010, with satisfactory final recovery. The first operation involved resection of 3 parathyroid glands in the normal position; the second operation involved removal of an ectopic parathyroid gland, combined with parathyroid gland autotransplantation; the third operation was performed to resect suspected recurrent parathyroid gland; the fourth operation involved partial excision of the autotransplanted parathyroid glands. Accurate preoperative localized diagnosis and optimal surgical approach play key roles in the prevention and treatment of SHPT; postoperative recurrence of SHPT caused by ectopic or autotransplanted parathyroid gland should receive more attention.

  14. Expression of miR-21 and its targets (PTEN, PDCD4, TM1) in flat epithelial atypia of the breast in relation to ductal carcinoma in situ and invasive carcinoma

    PubMed Central

    2009-01-01

    Background Flat epithelial atypia (FEA) of the breast is characterised by a few layers of mildly atypical luminal epithelial cells. Genetic changes found in ductal carcinoma in situ (DCIS) and invasive ductal breast cancer (IDC) are also found in FEA, albeit at a lower concentration. So far, miRNA expression changes associated with invasive breast cancer, like miR-21, have not been studied in FEA. Methods We performed miRNA in-situ hybridization (ISH) on 15 cases with simultaneous presence of normal breast tissue, FEA and/or DCIS and 17 additional cases with IDC. Expression of the miR-21 targets PDCD4, TM1 and PTEN was investigated by immunohistochemistry. Results Two out of fifteen cases showed positive staining for miR-21 in normal breast ductal epithelium, seven out of fifteen cases were positive in the FEA component and nine out of twelve cases were positive in the DCIS component. A positive staining of miR-21 was observed in 15 of 17 IDC cases. In 12 cases all three components were present in one tissue block and an increase of miR-21 from normal breast to FEA and to DCIS was observed in five cases. In three cases the FEA component was negative, whereas the DCIS component was positive for miR-21. In three other cases, normal, FEA and DCIS components were negative for miR-21 and in the last case all three components were positive. Overall we observed a gradual increase in percentage of miR-21 positive cases from normal, to FEA, DCIS and IDC. Immunohistochemical staining for PTEN revealed no obvious changes in staining intensities in normal, FEA, DCIS and IDC. Cytoplasmic staining of PDCD4 increased from normal to IDC, whereas, the nuclear staining decreased. TM1 staining decreased from positive in normal breast to negative in most DCIS and IDC cases. In FEA, the staining pattern for TM1 was similar to normal breast tissue. Conclusion Upregulation of miR-21 from normal ductal epithelial cells of the breast to FEA, DCIS and IDC parallels morphologically defined carcinogenesis. No clear relation was observed between the staining pattern of miR-21 and its previously reported target genes. PMID:19473551

  15. Transperineal ultrasound in the assessment of haemorrhoids and haemorrhoidectomy: a pilot study.

    PubMed

    Zbar, A P; Murison, R

    2010-06-01

    The purpose of the study was the measurement of the anal cushion area using static transperineal ultrasound in a group of patients with symptomatic grade III and IV haemorrhoids about to undergo haemorrhoidectomy and compare them with a group of age-matched normals and the measured area following haemorrhoidectomy. Transperineal sonography was performed using a linear transducer measuring the anal cushion area by subtracting the measured luminal diameter of the undisturbed anal canal from the inner border of the internal anal sphincter. Measures were made 6 weeks following haemorrhoidectomy. Comparisons were made between 22 normals and 36 patients with haemorrhoids (31 evaluable post-operatively). The median area of normals was 0.78 cm², that of pre-operative patients 2.25 cm² and that of post-operative cases 1.20 cm². There was a significant difference between pre- and post-operative cases with cushion areas of normal patients being significantly lower than post-operative cases. Variance of measurement in all 3 groups was negligible. Static transperineal sonography measuring the anal cushion area is reproducible and shows marked differences between normals and patients with symptomatic haemorrhoids. There is a marked effect on measured area resultant from haemorrhoidectomy.

  16. Severe Neck Pain with Fever: Is it Meningitis?

    PubMed

    McCormick, Angela

    2012-12-01

    A 58-year-old male patient presented to the emergency department with complaints of severe neck pain. He admitted to drug use but denied using intravenous (IV) drugs. On exam, he had a fever of 100.7°F, positive Kernig's sign, and normal neurologic exam. The patient was suspected to have bacterial meningitis and was started on IV antibiotics. The next day the patient developed decreased hand grip. Magnetic resonance imaging of the spine the next day showed a soft-tissue mass impinging on the spinal canal. The patient was subsequently taken to the operating room where the epidural abscess was drained.

  17. Association of anti-sperm antibodies with chronic prostatitis: A systematic review and meta-analysis.

    PubMed

    Jiang, Yumei; Cui, Dong; Du, Yuefeng; Lu, Jun; Yang, Lin; Li, Jinmei; Zhang, Jing; Bai, Xiaojing

    2016-11-01

    Chronic prostatitis is a risk factor for impaired male fertility potential, and anti-sperm antibodies (ASAs) cause the autoimmune disease immune infertility, which has a negative effect on semen parameters. Current studies have investigated the ASA-positive relationship between chronic prostatitis versus normal controls, but have shown inconsistent results. Hence, we systematic searched the PubMed, EMBASE, Science Direct/Elsevier, Medline, and the Cochrane Library up to October 2015 for case-control studies that involved the ASA-positive relationship between chronic prostatitis patients versus normal controls. The meta-analysis was performed with Review Manager and Stata software. After literature search, six studies were identified, including 721 cases of chronic prostatitis and 160 normal controls. Our results illustrated a significant correlation of the ASA-positive relationship between chronic prostatitis patients versus normal controls. The combined odds ratio of the ASA-positive rate in chronic prostatitis patients and normal controls was 3.26 (1.86-5.71). There was also a significant correlation of the ASA-positive relationship between National Institutes of Health (NIH) III versus normal controls, and the combined OR was 2.46 (1.10-5.51). However, there was no significant correlation of the ASA-positive relationship between National Institutes of Health (NIH) II versus normal controls. The present study illustrates that the positive rate of ASAs in chronic prostatitis patients was significantly higher than in the control group, suggesting that chronic prostatitis has a negative effect on male reproductive function. However, studies with larger samples are needed to better illuminate the correlation between ASAs and chronic prostatitis. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  18. Philippine refiner completes diesel desulfurization project

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Candido, S.S.; Crisostomo, E.V.

    1997-01-27

    In anticipation of tightening sulfur specifications on diesel fuel, Petron Corp. built a new 18,000 b/sd gas oil desulfurization unit (GODU) at its refinery in Bataan, Philippines. The GODU gives Petron sufficient diesel oil desulfurization capacity to meet demand for lower-sulfur diesel in the country. The project places the refinery in a pacesetter position to comply with the Philippine government`s moves to reduce air pollution, especially in urban centers, by reducing the sulfur specification for diesel to 0.5 wt% in 1996 from 0.7 wt% at the start of the project. Performance tests and initial operations of the unit have revealedmore » a desulfurization efficiency of 91% vs. a guaranteed efficiency of 90%. A feed sulfur content of 1.33 wt% is reduced to 0.12 wt% at normal operating conditions. Operating difficulties during start-up were minimized through use of a detailed prestartup check conducted during the early stages of construction work.« less

  19. Sodium heat pipe use in solar Stirling power conversion systems

    NASA Astrophysics Data System (ADS)

    Zimmerman, W. F.; Divakaruni, S. M.; Won, Y. S.

    1980-08-01

    Sodium heat pipes were selected for use as a thermal transport method in a focus-mounted, distributed concentrator solar Stirling power conversion system intended to produce 15-20 kWe per unit. Heat pipes were used both to receive thermal power in the solar receiver and to transmit it to a secondary heat pipe containing both latent heat salt (for up to 1.25 hours of thermal storage) and the heat exchanger of the Stirling engine. Experimental tests were performed on five solar receiver heat pipes with various internal wicking configurations. The performance of the heat pipes at various power levels and operating attitudes was investigated at temperatures near 1550 F; the unidirectional heat transfer in these heat pipes was demonstrated in normal operating attitudes and particularly in the inverted position required during overnight stowage of the concentrator.

  20. Generation of coherent states of photon-added type via pathway of eigenfunctions

    NASA Astrophysics Data System (ADS)

    Górska, K.; Penson, K. A.; Duchamp, G. H. E.

    2010-09-01

    We obtain and investigate the regular eigenfunctions of simple differential operators xr dr + 1/dxr + 1, r = 1, 2, ..., with the eigenvalues equal to 1. With the help of these eigenfunctions, we construct a non-unitary analogue of a boson displacement operator which will be acting on the vacuum. In this way, we generate collective quantum states of the Fock space which are normalized and equipped with the resolution of unity with the positive weight functions that we obtain explicitly. These states are thus coherent states in the sense of Klauder. They span the truncated Fock space without first r lowest-lying basis states: |0rang, |1rang, ..., |r - 1rang. These states are squeezed, sub-Poissonian in nature and reminiscent of photon-added states in Agarwal and Tara (1991 Phys. Rev. A 43 492).

  1. Protecting the GEO Environment: Policies and Practices

    NASA Technical Reports Server (NTRS)

    Johnson, Nicholas L.; McKay, Gordon A. (Technical Monitor)

    1999-01-01

    The geosynchronous orbital regime has long been recognized as a unique space resource, dictating special measures to ensure its continuing use for future generations. During the past 20 years a variety of national and international policies have been developed to preserve this environment. A review of current practices involving the deployment and disposal of geosynchronous spacecraft, associated upper stages and apogee kick motors, and geosynchronous orbit transfer objects indicates both positive and negative trends. Most spacecraft operators are indeed performing end-of-mission maneuvers, but the boost altitudes normally fall short of policy guidelines. Russia, a major operator in geosynchronous orbit, maneuvers only 1 in 3 spacecraft out of the region, while China has never refired a spacecraft above GEO. The viability of voluntary protection measures for this regime depends upon the responsible actions of the aerospace community as a whole.

  2. Cavity-Dumped Communication Laser Design

    NASA Technical Reports Server (NTRS)

    Roberts, W. T.

    2003-01-01

    Cavity-dumped lasers have significant advantages over more conventional Q-switched lasers for high-rate operation with pulse position modulation communications, including the ability to emit laser pulses at 1- to 10-megahertz rates, with pulse widths of 0.5 to 5 nanoseconds. A major advantage of cavity dumping is the potential to vary the cavity output percentage from pulse to pulse, maintaining the remainder of the energy in reserve for the next pulse. This article presents the results of a simplified cavity-dumped laser model, establishing the requirements for cavity efficiency and projecting the ultimate laser efficiency attainable in normal operation. In addition, a method of reducing or eliminating laser dead time is suggested that could significantly enhance communication capacity. The design of a laboratory demonstration laser is presented with estimates of required cavity efficiency and demonstration potential.

  3. Sodium heat pipe use in solar Stirling power conversion systems

    NASA Technical Reports Server (NTRS)

    Zimmerman, W. F.; Divakaruni, S. M.; Won, Y. S.

    1980-01-01

    Sodium heat pipes were selected for use as a thermal transport method in a focus-mounted, distributed concentrator solar Stirling power conversion system intended to produce 15-20 kWe per unit. Heat pipes were used both to receive thermal power in the solar receiver and to transmit it to a secondary heat pipe containing both latent heat salt (for up to 1.25 hours of thermal storage) and the heat exchanger of the Stirling engine. Experimental tests were performed on five solar receiver heat pipes with various internal wicking configurations. The performance of the heat pipes at various power levels and operating attitudes was investigated at temperatures near 1550 F; the unidirectional heat transfer in these heat pipes was demonstrated in normal operating attitudes and particularly in the inverted position required during overnight stowage of the concentrator.

  4. The Geometric Phase of Stock Trading.

    PubMed

    Altafini, Claudio

    2016-01-01

    Geometric phases describe how in a continuous-time dynamical system the displacement of a variable (called phase variable) can be related to other variables (shape variables) undergoing a cyclic motion, according to an area rule. The aim of this paper is to show that geometric phases can exist also for discrete-time systems, and even when the cycles in shape space have zero area. A context in which this principle can be applied is stock trading. A zero-area cycle in shape space represents the type of trading operations normally carried out by high-frequency traders (entering and exiting a position on a fast time-scale), while the phase variable represents the cash balance of a trader. Under the assumption that trading impacts stock prices, even zero-area cyclic trading operations can induce geometric phases, i.e., profits or losses, without affecting the stock quote.

  5. Management of occiput posterior position in the second stage of labor: a survey of midwifery practice in Australia.

    PubMed

    Phipps, Hala; de Vries, Brad; Jagadish, Ujvala; Hyett, Jon

    2014-03-01

    The management of the occiput posterior (OP) position has been controversial for many years. Manual rotation can be performed by midwives and could reduce cesarean sections and instrumental births. We aimed to determine current midwifery views, knowledge, and practice of manual rotation. A de-identified, self-reported questionnaire was e-mailed to all Australian College of Midwives full members (n = 3,997). Of 3,182 surveyed, 57 percent (1,817) responded, of whom 51 percent (920) were currently practicing midwifery. Seventy-seven percent of midwives thought that manual rotation at full dilatation was a valid intervention. Sixty-four percent stated the procedure was acceptable before instrumental delivery, but 30 percent were unsure. Most practicing midwives (93%) had heard of manual rotation, but only 18 percent had performed one in the last year. Midwives would support the routine performance of manual rotation for OP position if it reduced operative births from 68 to 50 percent and would support manual rotation for occiput transverse (OT) position if it reduced operative births from 39 to 25 percent. This study indicates that manual rotation is considered acceptable by most midwives in Australia, yet is only performed by a minority. Midwives would be willing to perform prophylactic manual rotation if it was known to facilitate normal vaginal births suggesting a scope to introduce this procedure into widespread clinical practice. © 2014, Copyright the Authors Journal compilation © 2014, Wiley Periodicals, Inc.

  6. [A case of pulmonary embolism and a case of ileus as complications after laparoscopic radical prostatectomy].

    PubMed

    Fujita, Akiko; Yamazaki, Yasuo; Yamashita, Tomomitsu; Ibuki, Takae; Hosokawa, Toyoshi; Tanaka, Yoshifumi

    2003-01-01

    In recent years, the use of laparoscopic techniques for surgical operations has been increasing, because this procedure is less invasive and is excellent in regard to patient's quality of life. Normally, complications are rare in laparoscopic surgery. However, we experienced a case of pulmonary embolism and one case of ileus as complications after laparoscopic radical prostatectomy. Especially, in this type of operation, the danger of complications is increased due to the severe head down and lithotomy position, which is employed to ensure a good view during operation. In this particular case, the long duration of operation may have been another related risk factor. There were no risk factors for pulmonary embolism such as those encountered when a patient is aged, obese, or bed ridden for a long time. However, an intermittent air massage must be applied to the lower legs to prevent thrombus due to poor blood circulation of the lower extremities below the knee during the surgery. It is also necessary to change the posture of the patient frequently after the operation. In addition, the administration of low molecular weight heparin may also be effective.

  7. Orthopedic trauma surgery in the morbidly obese patient.

    PubMed

    Bozzio, Anthony E; Gala, Raj J; Villasenor, Mario A; Hao, Jiandon; Mauffrey, Cyril

    2014-05-01

    The treatment of morbidly obese patients in orthopedic trauma differs in many ways compared to injured patients with normal body mass indices. This paper highlights key differences and ways to overcome obstacles. We present specific tips, as well as considerations for initial planning, positioning for surgery, intra-operative strategies, and a discussion on both anesthesia and imaging. Several treatment strategies have been shown to have better results in morbidly obese patients. Pre-operative planning is necessary for minimizing risk to the patient. The prevalence of morbid obesity has increased in the USA in the past quarter century. Treatment for orthopedic injuries in morbidly obese patients requires a multidisciplinary approach that addresses not only their orthopedic injuries, but also medical co-morbidities. A team of medicine doctors, anesthesiologists, X-ray technicians, physical and occupational therapists, respiratory therapists, and social workers is needed in addition to the orthopedic surgeon. Modifications in both pre-operative planning and intra-operative strategies may be necessary in order to accommodate the patient. This paper presents numerous technical tips that can aid in providing stable fixation for fractures, as well as addressing peri-operative issues specific to the morbidly obese.

  8. 14 CFR 23.231 - Longitudinal stability and control.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... AIRCRAFT AIRWORTHINESS STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Flight Ground... rebound during landing or takeoff. Wheel brakes must operate smoothly and may not induce any undue... characteristics at any normal operating speed on the water. ...

  9. 14 CFR 23.231 - Longitudinal stability and control.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... AIRCRAFT AIRWORTHINESS STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Flight Ground... rebound during landing or takeoff. Wheel brakes must operate smoothly and may not induce any undue... characteristics at any normal operating speed on the water. ...

  10. 14 CFR 23.231 - Longitudinal stability and control.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... AIRCRAFT AIRWORTHINESS STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Flight Ground... rebound during landing or takeoff. Wheel brakes must operate smoothly and may not induce any undue... characteristics at any normal operating speed on the water. ...

  11. 14 CFR 23.231 - Longitudinal stability and control.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... AIRCRAFT AIRWORTHINESS STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Flight Ground... rebound during landing or takeoff. Wheel brakes must operate smoothly and may not induce any undue... characteristics at any normal operating speed on the water. ...

  12. 14 CFR 23.231 - Longitudinal stability and control.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... AIRCRAFT AIRWORTHINESS STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Flight Ground... rebound during landing or takeoff. Wheel brakes must operate smoothly and may not induce any undue... characteristics at any normal operating speed on the water. ...

  13. 45 CFR 90.14 - Exceptions to the rules against age discrimination. Normal operation or statutory objective of...

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    .... Normal operation or statutory objective of any program or activity. 90.14 Section 90.14 Public Welfare DEPARTMENT OF HEALTH AND HUMAN SERVICES GENERAL ADMINISTRATION NONDISCRIMINATION ON THE BASIS OF AGE IN... operation or statutory objective of any program or activity. A recipient is permitted to take an action...

  14. A novel gamma-fitting statistical method for anti-drug antibody assays to establish assay cut points for data with non-normal distribution.

    PubMed

    Schlain, Brian; Amaravadi, Lakshmi; Donley, Jean; Wickramasekera, Ananda; Bennett, Donald; Subramanyam, Meena

    2010-01-31

    In recent years there has been growing recognition of the impact of anti-drug or anti-therapeutic antibodies (ADAs, ATAs) on the pharmacokinetic and pharmacodynamic behavior of the drug, which ultimately affects drug exposure and activity. These anti-drug antibodies can also impact safety of the therapeutic by inducing a range of reactions from hypersensitivity to neutralization of the activity of an endogenous protein. Assessments of immunogenicity, therefore, are critically dependent on the bioanalytical method used to test samples, in which a positive versus negative reactivity is determined by a statistically derived cut point based on the distribution of drug naïve samples. For non-normally distributed data, a novel gamma-fitting method for obtaining assay cut points is presented. Non-normal immunogenicity data distributions, which tend to be unimodal and positively skewed, can often be modeled by 3-parameter gamma fits. Under a gamma regime, gamma based cut points were found to be more accurate (closer to their targeted false positive rates) compared to normal or log-normal methods and more precise (smaller standard errors of cut point estimators) compared with the nonparametric percentile method. Under a gamma regime, normal theory based methods for estimating cut points targeting a 5% false positive rate were found in computer simulation experiments to have, on average, false positive rates ranging from 6.2 to 8.3% (or positive biases between +1.2 and +3.3%) with bias decreasing with the magnitude of the gamma shape parameter. The log-normal fits tended, on average, to underestimate false positive rates with negative biases as large a -2.3% with absolute bias decreasing with the shape parameter. These results were consistent with the well known fact that gamma distributions become less skewed and closer to a normal distribution as their shape parameters increase. Inflated false positive rates, especially in a screening assay, shifts the emphasis to confirm test results in a subsequent test (confirmatory assay). On the other hand, deflated false positive rates in the case of screening immunogenicity assays will not meet the minimum 5% false positive target as proposed in the immunogenicity assay guidance white papers. Copyright 2009 Elsevier B.V. All rights reserved.

  15. UARS in-flight jitter study for EOS

    NASA Technical Reports Server (NTRS)

    Molnar, John; Garnek, Mike

    1993-01-01

    Response data collected from gyroscopes on board the Upper Atmosphere Research Satellite (UARS) provided a unique opportunity to analyze actual flight pointing jitter data. Flight modal frequencies and damping values are derived from the measured data using an Eigensystem Realization Algorithm (ERA). Flight frequencies at various solar array positions are compared to analytical predictions obtained with a Finite Element Model. The solar array modal frequencies change with position due to the modes acting about different spacecraft inertial axes. Higher order modes were difficult to identify due to the limited instrumentation. Future flight jitter studies on other spacecraft would be significantly aided by additional instrumentation. Spacecraft jitter due to continuous disturbance sources such as the 1.6 meter scanning microwave antenna, the solar array drive, and reaction wheels is presented. The solar array drive disturbance dominates the spacecraft response during normal operation.

  16. Predictive role of prenasal thickness and nasal bone for Down syndrome in the second trimester.

    PubMed

    Ozcan, Tulin; Özlü, Tülay; Allen, Julie; Peterson, Jeanne; Pressman, Eva K

    2013-12-01

    To assess the efficacy of prenasal thickness (PNT) and nasal bone (NB) for prediction of Down syndrome (DS) fetuses in the second trimester ultrasound examination. PNT was measured from stored two-dimensional fetal profile images taken at 15-23 weeks in 242 fetuses with normal karyotype (Group 1) and 24 fetuses with DS (Group 2). It was measured as the shortest distance from the anterior edge of the lowest part of the frontal bone to the skin. The efficacy of PNT, NB, PNT/NB and biparietal diameter (BPD)/NB was evaluated for prediction of DS. PNT values increased with gestational age in normal fetuses. PNT measurement was ≥95th percentile in 54.2% (13/24) of the DS cases and 2.9% of the normal cases. Receiver operator curve analysis showed that PNT/NB ratio had the best area under the curve with a detection rate of 80% for a false positive rate of 5% at a cut-off value of 0.76. PNT is increased in fetuses with DS as compared to normal fetuses. PNT/NB≥0.76 in the second trimester is a better predictor of DS than the use of PNT or NB alone. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  17. Control logic for exhaust gas driven turbocharger

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Adeff, G.A.

    1991-12-31

    This patent describes a method of controlling an exhaust gas driven turbocharger supplying charge air for an internal combustion engine powering vehicle, the turbocharger being adjustable from a normal mode to a power mode in which the charge air available to the engine during vehicle acceleration is increased over that available when the turbocharger is in the normal mode, the vehicle including engine power control means switchable by the vehicle operator from a normal mode to a power mode so that the vehicle operator may selectively elect either the normal mode or the power mode, comprising the steps of measuringmore » the speed of the vehicle, permitting the vehicle operator to elect either the power mode or the normal mode for a subsequent vehicle acceleration, and then adjusting the turbocharger to the power mode when the speed of the vehicle is less than a predetermined reference speed and the vehicle operator has elected to power mode to increase the charge air available to the engine and thereby increasing engine power on a subsequent acceleration of the vehicle.« less

  18. Step buffer layer of Al0.25Ga0.75N/Al0.08Ga0.92N on P-InAlN gate normally-off high electron mobility transistors

    NASA Astrophysics Data System (ADS)

    Shrestha, Niraj M.; Li, Yiming; Chang, E. Y.

    2016-07-01

    Normally-off AlGaN/GaN high electron mobility transistors (HEMTs) are indispensable devices for power electronics as they can greatly simplify circuit designs in a cost-effective way. In this work, the electrical characteristics of p-type InAlN gate normally-off AlGaN/GaN HEMTs with a step buffer layer of Al0.25Ga0.75N/Al0.1Ga0.9N is studied numerically. Our device simulation shows that a p-InAlN gate with a step buffer layer allows the transistor to possess normally-off behavior with high drain current and high breakdown voltage simultaneously. The gate modulation by the p-InAlN gate and the induced holes appearing beneath the gate at the GaN/Al0.25Ga0.75N interface is because a hole appearing in the p-InAlN layer can effectively vary the threshold voltage positively. The estimated threshold voltage of the normally-off HEMTs explored is 2.5 V at a drain bias of 25 V, which is 220% higher than the conventional p-AlGaN normally-off AlGaN/GaN gate injection transistor (GIT). Concurrently, the maximum current density of the explored HEMT at a drain bias of 10 V slightly decreases by about 7% (from 240 to 223 mA mm-1). At a drain bias of 15 V, the current density reached 263 mA mm-1. The explored structure is promising owing to tunable positive threshold voltage and the maintenance of similar current density; notably, its breakdown voltage significantly increases by 36% (from 800 V, GIT, to 1086 V). The engineering findings of this study indicate that novel p-InAlN for both the gate and the step buffer layer can feature a high threshold voltage, large current density and high operating voltage for advanced AlGaN/GaN HEMT devices.

  19. Normal form decomposition for Gaussian-to-Gaussian superoperators

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    De Palma, Giacomo; INFN, Pisa; Mari, Andrea

    2015-05-15

    In this paper, we explore the set of linear maps sending the set of quantum Gaussian states into itself. These maps are in general not positive, a feature which can be exploited as a test to check whether a given quantum state belongs to the convex hull of Gaussian states (if one of the considered maps sends it into a non-positive operator, the above state is certified not to belong to the set). Generalizing a result known to be valid under the assumption of complete positivity, we provide a characterization of these Gaussian-to-Gaussian (not necessarily positive) superoperators in terms ofmore » their action on the characteristic function of the inputs. For the special case of one-mode mappings, we also show that any Gaussian-to-Gaussian superoperator can be expressed as a concatenation of a phase-space dilatation, followed by the action of a completely positive Gaussian channel, possibly composed with a transposition. While a similar decomposition is shown to fail in the multi-mode scenario, we prove that it still holds at least under the further hypothesis of homogeneous action on the covariance matrix.« less

  20. Design and simulation of optoelectronic complementary dual neural elements for realizing a family of normalized vector 'equivalence-nonequivalence' operations

    NASA Astrophysics Data System (ADS)

    Krasilenko, Vladimir G.; Nikolsky, Aleksandr I.; Lazarev, Alexander A.; Magas, Taras E.

    2010-04-01

    Equivalence models (EM) advantages of neural networks (NN) are shown in paper. EMs are based on vectormatrix procedures with basic operations of continuous neurologic: normalized vector operations "equivalence", "nonequivalence", "autoequivalence", "autononequivalence". The capacity of NN on the basis of EM and of its modifications, including auto-and heteroassociative memories for 2D images, exceeds in several times quantity of neurons. Such neuroparadigms are very perspective for processing, recognition, storing large size and strongly correlated images. A family of "normalized equivalence-nonequivalence" neuro-fuzzy logic operations on the based of generalized operations fuzzy-negation, t-norm and s-norm is elaborated. A biologically motivated concept and time pulse encoding principles of continuous logic photocurrent reflexions and sample-storage devices with pulse-width photoconverters have allowed us to design generalized structures for realization of the family of normalized linear vector operations "equivalence"-"nonequivalence". Simulation results show, that processing time in such circuits does not exceed units of micro seconds. Circuits are simple, have low supply voltage (1-3 V), low power consumption (milliwatts), low levels of input signals (microwatts), integrated construction, satisfy the problem of interconnections and cascading.

  1. Testing the Efficacy of Synthetic Vision during Non-Normal Operations as an Enabling Technology for Equivalent Visual Operations

    NASA Technical Reports Server (NTRS)

    Kramer, Lynda J.; Williams, Steven P.

    2008-01-01

    Synthetic Vision (SV) may serve as a revolutionary crew/vehicle interface enabling technology to meet the challenges of the Next Generation Air Transportation System Equivalent Visual Operations (EVO) concept that is, the ability to achieve or even improve on the safety of Visual Flight Rules (VFR) operations, maintain the operational tempos of VFR, and potentially retain VFR procedures independent of actual weather and visibility conditions. One significant challenge lies in the definition of required equipage on the aircraft and on the airport to enable the EVO concept objective. An experiment was conducted to evaluate the effects of the presence or absence of SV, the location (head-up or head-down) of this information during an instrument approach, and the type of airport lighting information on landing minima. Another key element of the testing entailed investigating the pilot s awareness and reaction to non-normal events (i.e., failure conditions) that were unexpectedly introduced into the experiment. These non-normals are critical determinants in the underlying safety of all-weather operations. This paper presents the experimental results specific to pilot response to non-normal events using head-up and head-down synthetic vision displays.

  2. A novel combined hemipelvic endoprosthesis for peri-acetabular tumours involving sacroiliac joint: a finite element study.

    PubMed

    Wang, Bo; Sun, Peidong; Xie, Xianbiao; Wu, Weidong; Tu, Jian; Ouyang, Jun; Shen, Jingnan

    2015-11-01

    Our aim was to introduce a novel combined hemipelvic endoprosthesis for pelvic reconstruction after Enneking type I/II/IV resection and to evaluate the biomechanical properties of the endoprosthesis using finite element analysis. A three-dimensional finite element model of the postoperative pelvis was developed based on computed tomography (CT) images of the patient with the best post-operative limb function. A force of 400 N was applied along the longitudinal axis of the normal and post-operative pelvis for two positions: standing on two feet and sitting. Stress-distribution analysis was performed in both positions, and results were compared. Prosthesis improvements were simulated by intervertebral fusion and extra screw fixation. In the normal pelvis, stress distributions were mostly concentrated on the superior area of the acetabulum, arcuate line, sacroiliac joint and sacral midline in both static conditions, and peak stresses of 1.52 MPa and 4.53 MPa were observed at the superior area of the greater sciatic notch and ischial tuberosity, respectively. For the reconstructed hemipelvis, stress distributions were concentrated on the connecting rods of the acetabular component and the proximal segment of the pedicle rods, and peak stresses of 252 MPa and 213 MPa were observed on the proximal pedicle rods of the fourth lumbar vertebra for standing and sitting, respectively. Interbody fusion of the fourth and fifth lumbar vertebrae and extra screw fixation to the sacrum decreased the peak stresses by 33.0 % and 18.3 % while standing and by 10.8 % and 6.6 % while sitting. Reconstruction with combined hemipelvic endoprosthesis after types I/II/IV resection of the pelvis fulfilled physiological and biomechanical demands of the hemipelvis and yielded good biomechanical characteristics.

  3. Diagnostic capability of spectral-domain optical coherence tomography for glaucoma.

    PubMed

    Wu, Huijuan; de Boer, Johannes F; Chen, Teresa C

    2012-05-01

    To determine the diagnostic capability of spectral-domain optical coherence tomography in glaucoma patients with visual field defects. Prospective, cross-sectional study. Participants were recruited from a university hospital clinic. One eye of 85 normal subjects and 61 glaucoma patients with average visual field mean deviation of -9.61 ± 8.76 dB was selected randomly for the study. A subgroup of the glaucoma patients with early visual field defects was calculated separately. Spectralis optical coherence tomography (Heidelberg Engineering, Inc) circular scans were performed to obtain peripapillary retinal nerve fiber layer (RNFL) thicknesses. The RNFL diagnostic parameters based on the normative database were used alone or in combination for identifying glaucomatous RNFL thinning. To evaluate diagnostic performance, calculations included areas under the receiver operating characteristic curve, sensitivity, specificity, positive predictive value, negative predictive value, positive likelihood ratio, and negative likelihood ratio. Overall RNFL thickness had the highest area under the receiver operating characteristic curve values: 0.952 for all patients and 0.895 for the early glaucoma subgroup. For all patients, the highest sensitivity (98.4%; 95% confidence interval, 96.3% to 100%) was achieved by using 2 criteria: ≥ 1 RNFL sectors being abnormal at the < 5% level and overall classification of borderline or outside normal limits, with specificities of 88.9% (95% confidence interval, 84.0% to 94.0%) and 87.1% (95% confidence interval, 81.6% to 92.5%), respectively, for these 2 criteria. Statistical parameters for evaluating the diagnostic performance of the Spectralis spectral-domain optical coherence tomography were good for early perimetric glaucoma and were excellent for moderately advanced perimetric glaucoma. Copyright © 2012 Elsevier Inc. All rights reserved.

  4. [Does intraoperative nerve monitoring reduce the rate of recurrent nerve palsies during thyroid surgery?].

    PubMed

    Timmermann, W; Dralle, H; Hamelmann, W; Thomusch, O; Sekulla, C; Meyer, Th; Timm, S; Thiede, A

    2002-05-01

    Two different aspects of the influence of neuromonitoring on the possible reduction of post-operative recurrent laryngeal nerve palsies require critical examination: the nerve identification and the monitoring of it's functions. Due to the additional information from the EMG signals, neuromonitoring is the best method for identifying the nerves as compared to visual identification alone. There are still no randomized studies available that compare the visual and electrophysiological recurrent laryngeal nerve detection in thyroid operations with respect to the postoperative nerve palsies. Nevertheless, comparisons with historical collectives show that a constant low nerve-palsy-rate was achieved with electrophysiological detection in comparison to visual detection. The rate of nerve identification is normally very high and amounts to 99 % in our own patients. The data obtained during the "Quality assurance of benign and malignant Goiter" study show that in hemithyreoidectomy and subtotal resection, lower nerve-palsy-rates are achieved with neuromonitoring as compared to solely visual detection. Following subtotal resection, this discrepancy becomes even statistically significant. While monitoring the nerve functions with the presently used neuromonitoring technique, it is possible to observe the EMG-signal remaining constant or decreasing in volume. Assuming that a constant neuromonitoring signal represents a normal vocal cord, our evaluation shows that there is a small percentage of false negative and positive results. Looking at the permanent recurrent nerve palsy rates, this method has a specificity of 98 %, a sensitivity of 100 %, a positive prognostic value of 10 %, and a negative prognostic value of 100 %. Although an altered neuromonitoring signal can be taken as a clear indication of eventual nerve damage, an absolutely reliable statement about the postoperative vocal cord function is presently not possible with intraoperative neuromonitoring.

  5. Effects of depressive disorder on false memory for emotional information.

    PubMed

    Yeh, Zai-Ting; Hua, Mau-Sun

    2009-01-01

    This study explored with a false memory paradigm whether (1) depressed patients revealed more false memories and (2) whether more negative false than positive false recognition existed in subjects with depressive disorders. Thirty-two patients suffering from a major depressive episode (DSM-IV criteria), and 30 age- and education-matched normal control subjects participated in this study. After the presentation of a list of positive, negative, and neutral association items in the learning phase, subjects were asked to give a yes/no response in the recognition phase. They were also asked to rate 81 recognition items with emotional valence scores. The results revealed more negative false memories in the clinical depression group than in the normal control group; however, we did not find more negative false memories than positive ones in patients. When compared with the normal group, a more conservative response criterion for positive items was evident in patient groups. It was also found that when compared with the normal group, the subjects in the depression group perceived the positive items as less positive. On the basis of present results, it is suggested that depressed subjects judged the emotional information with criteria different from normal individuals, and patients' emotional memory intensity is attenuated by their mood.

  6. [Effect of Aβ1-42 injection on hippocampus cells in rats and protective role of polygona-polysaccharose for Alzheimer's disease].

    PubMed

    Yi, Yuxin; Wu, Shixing; Ye, Maosheng; Zeng, Yi; Zhang, Ping; Xie, Yiqun

    2014-04-01

    To determine the effect of polygona-polysaccharose (PP) on learning and memory ability in rats with Alzheimer's disease (AD). Forty five Sprague-Dawley rats were assigned into 3 groups. Rats in the sham-operated group were injected with normal saline. Rats in the Aβ group were injected with Aβ1-42. Rats in the PP group were injected with 16% PP solution for 45 days consecutively. The Morris water maze was used to investigate the ability of learning and memory in the rats. The effect of Aβ and PP on the hippocampus cells was observed by HE and Congo red staining of methanol. Rats in the sham-operated group had no obvious morphological change; and morphology of rats in the PP group was basicaly normal. The layer of pyramidal cells in the Aβ group was decreased. The cells appeared sparse and irregular and became smaller. Karyopyknosis and vacuolar degeneration cells were also found. More positive staining materials aggradated in the Aβ group compared with the PP group by Congo red staining (P<0.05). Aβ infusion into the hippocampus results in the impairment of the neuronal degeneration in the rats, which shows similar characterizations of AD. PP can reduce the deposition of Aβ in the hippocampus.

  7. Computer-based image analysis of one-dimensional electrophoretic gels used for the separation of DNA restriction fragments.

    PubMed Central

    Gray, A J; Beecher, D E; Olson, M V

    1984-01-01

    A stand-alone, interactive computer system has been developed that automates the analysis of ethidium bromide-stained agarose and acrylamide gels on which DNA restriction fragments have been separated by size. High-resolution digital images of the gels are obtained using a camera that contains a one-dimensional, 2048-pixel photodiode array that is mechanically translated through 2048 discrete steps in a direction perpendicular to the gel lanes. An automatic band-detection algorithm is used to establish the positions of the gel bands. A color-video graphics system, on which both the gel image and a variety of operator-controlled overlays are displayed, allows the operator to visualize and interact with critical stages of the analysis. The principal interactive steps involve defining the regions of the image that are to be analyzed and editing the results of the band-detection process. The system produces a machine-readable output file that contains the positions, intensities, and descriptive classifications of all the bands, as well as documentary information about the experiment. This file is normally further processed on a larger computer to obtain fragment-size assignments. Images PMID:6320097

  8. Higher operation temperature quadrant photon detectors of 2-11 μm wavelength radiation with large photosensitive areas

    NASA Astrophysics Data System (ADS)

    Pawluczyk, J.; Sosna, A.; Wojnowski, D.; Koźniewski, A.; Romanis, M.; Gawron, W.; Piotrowski, J.

    2017-10-01

    We report on the quadrant photon HgCdTe detectors optimized for 2-11 μm wavelength spectral range and Peltier or no cooling, and photosensitive area of a quad-cell of 1×1 to 4×4 mm. The devices are fabricated as photoconductors or multiple photovoltaic cells connected in series (PVM). The former are characterized by a relatively uniform photosensitive area. The PVM photovoltaic cells are distributed along the wafer surface, comprising a periodical stripe structure with a period of 20 μm. Within each period, there is an insensitive gap/trench < 9 μm wide between stripe mesas. The resulting spatial quantization error prevents positioning of the beam spot of size close to the period, but becomes negligible for the optimal spot size comparable to a quadrant-cell area. The photoconductors produce 1/f noise with about 10 kHz knee frequency, due to bias necessary for their operation. The PVM photodiodes are typically operated at 0 V bias, so they generate no 1/f noise and operation from DC is enabled. At 230 K, upper corner frequency of 16 to 100 MHz is obtained for photoconductor and 60 to 80 MHz for PVM, normalized detectivity D* 6×107 cm×Hz1/2/W to >1.4×108 cm×Hz1/2/W for photoconductor and >1.7×108 cm·Hz1/2/W for PVM, allowing for position control of the radiation beam with submicron accuracy at 16 MHz, 10.6 μm wavelength of pulsed radiation spot of 0.8 mm dia at the close-to-maximal input radiation power density in a range of detector linear operation.

  9. The effect of mitomycin C trabeculectomy on the progression of visual field defect in normal-tension glaucoma.

    PubMed

    Hagiwara, Y; Yamamoto, T; Kitazawa, Y

    2000-03-01

    We investigated in a prospective fashion the visual prognosis and complications in normal-tension glaucoma following unilateral trabeculectomy with adjunctive mitomycin C. Trabeculectomy with adjunctive mitomycin C was carried out unilaterally in 21 cases of normal-tension glaucoma. Intraocular pressure (IOP), visual prognosis, and complications were compared between the operated eyes and the non-operated fellow eyes. The follow-up period ranged from 2 to 7 years. The IOP dropped significantly from 14.8+/-1.8 mmHg (mean +/- SD) to 9.6+/-3.9 mmHg in the operated eyes (P=0.0002, Wilcoxon signed-rank test), but did not drop in the non-operated eyes. The mean deviation (MD) was -12.69+/-6.41 dB preoperatively and -14.70+/-5.49 dB at the last clinic visit in the operated eyes, whereas in non-operated eyes it was -7.85+/-5.65 dB and -11.15+/-5.62 dB, respectively. The MD deteriorated significantly in both operated and non-operated eyes (operated eyes P=0.0239, non-operated eyes: P=0.0002; Wilcoxon signed-rank test). The MD slope was -0.37+/-0.60 dB/year and -0.71+/-0.89 dB/year for the operated and non-operated eyes, respectively (P=0.5243, Mann-Whitney U-test). Visual field deterioration was more frequently observed in the non-operated eyes by a pointwise definition of the progression (P<0.05, McNemar test). Visual acuity deteriorated in 6 of the operated eyes and in 5 of the non-operated eyes. Cataract developed in 6 (29%) of the 21 operated eyes, while among the non-operated eyes 4 (19%) developed cataract. Mitomycin C trabeculectomy is effective in delaying progression of visual field defect in normal-tension glaucoma, but complications may arise and cause some visual disturbance.

  10. 14 CFR 137.47 - Operation without position lights.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Operation without position lights. 137.47... AIRCRAFT OPERATIONS Operating Rules § 137.47 Operation without position lights. Notwithstanding part 91 of this chapter, an aircraft may be operated without position lights if prominent unlighted objects are...

  11. 14 CFR 137.47 - Operation without position lights.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 3 2012-01-01 2012-01-01 false Operation without position lights. 137.47... AIRCRAFT OPERATIONS Operating Rules § 137.47 Operation without position lights. Notwithstanding part 91 of this chapter, an aircraft may be operated without position lights if prominent unlighted objects are...

  12. 14 CFR 137.47 - Operation without position lights.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 3 2013-01-01 2013-01-01 false Operation without position lights. 137.47... AIRCRAFT OPERATIONS Operating Rules § 137.47 Operation without position lights. Notwithstanding part 91 of this chapter, an aircraft may be operated without position lights if prominent unlighted objects are...

  13. 14 CFR 137.47 - Operation without position lights.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 3 2011-01-01 2011-01-01 false Operation without position lights. 137.47... AIRCRAFT OPERATIONS Operating Rules § 137.47 Operation without position lights. Notwithstanding part 91 of this chapter, an aircraft may be operated without position lights if prominent unlighted objects are...

  14. Reliable multicast protocol specifications protocol operations

    NASA Technical Reports Server (NTRS)

    Callahan, John R.; Montgomery, Todd; Whetten, Brian

    1995-01-01

    This appendix contains the complete state tables for Reliable Multicast Protocol (RMP) Normal Operation, Multi-RPC Extensions, Membership Change Extensions, and Reformation Extensions. First the event types are presented. Afterwards, each RMP operation state, normal and extended, is presented individually and its events shown. Events in the RMP specification are one of several things: (1) arriving packets, (2) expired alarms, (3) user events, (4) exceptional conditions.

  15. Normal order and extended Wick theorem for a multiconfiguration reference wave function

    NASA Astrophysics Data System (ADS)

    Kutzelnigg, Werner; Mukherjee, Debashis

    1997-07-01

    A generalization of normal ordering and of Wick's theorem with respect to an arbitrary reference function Φ as some generalized "physical vacuum" is formulated in a different (but essentially equivalent) way than that suggested previously by one of the present authors. Guiding principles are that normal order operators with respect to any reference state must be expressible as linear combinations of those with respect to the genuine vacuum, that the vacuum expectation value of a normal order operator must vanish (with respect to the vacuum to which it is in normal order), and that the well-known formalism for a single Slater determinant as physical vacuum must be contained as a special case. The derivation is largely based on the concepts of "Quantum Chemistry in Fock space," which means that particle-number-conserving operators (excitation operators) play a central role. Nevertheless, the contraction rules in the frame of a generalized Wick theorem are derived, that hold for non-particle-number-conserving operators as well. The contraction rules are formulated and illustrated in terms of diagrams. The contractions involve the "residual n-particle density matrices" λ, which are the irreducible (non-factorizable) parts of the conventional n-particle density matrices γ, in the sense of a cumulant expansion for the density. A spinfree formulation is presented as well. The expression of the Hamiltonian in normal order with respect to a multiconfiguration reference function leads to a natural definition of a generalized Fock operator. MC-SCF-theory is easily worked out in this context. The paper concludes with a discussion of the excited configurations and the first-order interacting space, that underlies a perturbative coupled cluster type correction to the MCSCF function for an arbitrary reference function, and with general implications of the new formalism, that is related to "internally contracted multireference configuration interaction." The present generalization of normal ordering is not only valid for arbitrary reference functions, but also if the reference state is an ensemble state.

  16. Overcenter collet space station truss fastener

    NASA Technical Reports Server (NTRS)

    Sheridan, Philip L. (Inventor)

    1991-01-01

    A quick-connect fastener is arranged with a tubular body that is arranged to be engaged against the exterior surface of a hollow attachment fitting and coincidentally aligned with an opening in the fitting. A collet having normally-contracted fingers with outwardly-enlarged ends is operatively arranged in the body to be moved forwardly by an expander member mounted in the tubular body for advancing the collet fingers through the opening in the attachment fitting. Biasing means are arranged between the expander member and a toggle linkage in the tubular body which is selectively operated to urge the expander member forwardly into engagement with the collet fingers with an initial biasing force to advance their forward portions through the body opening and then expand them outwardly. The biasing means also provide a subsequent biasing force for retaining the collet members in their expanded positions once their enlarged forward end portions are on the opposite side of the body.

  17. In-line localized monitoring of catalyst activity in selective catalytic NO.sub.x reduction systems

    DOEpatents

    Muzio, Lawrence J [Laguna Niguel, CA; Smith, Randall A [Huntington Beach, CA

    2009-12-22

    Localized catalyst activity in an SCR unit for controlling emissions from a boiler, power plant, or any facility that generates NO.sub.x-containing flue gases is monitored by one or more modules that operate on-line without disrupting the normal operation of the facility. Each module is positioned over a designated lateral area of one of the catalyst beds in the SCR unit, and supplies ammonia, urea, or other suitable reductant to the catalyst in the designated area at a rate that produces an excess of the reductant over NO.sub.x on a molar basis through the designated area. Sampling probes upstream and downstream of the designated area draw samples of the gas stream for NO.sub.x analysis, and the catalyst activity is determined from the difference in NO.sub.x levels between the two probes.

  18. The Geometric Phase of Stock Trading

    PubMed Central

    2016-01-01

    Geometric phases describe how in a continuous-time dynamical system the displacement of a variable (called phase variable) can be related to other variables (shape variables) undergoing a cyclic motion, according to an area rule. The aim of this paper is to show that geometric phases can exist also for discrete-time systems, and even when the cycles in shape space have zero area. A context in which this principle can be applied is stock trading. A zero-area cycle in shape space represents the type of trading operations normally carried out by high-frequency traders (entering and exiting a position on a fast time-scale), while the phase variable represents the cash balance of a trader. Under the assumption that trading impacts stock prices, even zero-area cyclic trading operations can induce geometric phases, i.e., profits or losses, without affecting the stock quote. PMID:27556642

  19. Uniform convergence of multigrid V-cycle iterations for indefinite and nonsymmetric problems

    NASA Technical Reports Server (NTRS)

    Bramble, James H.; Kwak, Do Y.; Pasciak, Joseph E.

    1993-01-01

    In this paper, we present an analysis of a multigrid method for nonsymmetric and/or indefinite elliptic problems. In this multigrid method various types of smoothers may be used. One type of smoother which we consider is defined in terms of an associated symmetric problem and includes point and line, Jacobi, and Gauss-Seidel iterations. We also study smoothers based entirely on the original operator. One is based on the normal form, that is, the product of the operator and its transpose. Other smoothers studied include point and line, Jacobi, and Gauss-Seidel. We show that the uniform estimates for symmetric positive definite problems carry over to these algorithms. More precisely, the multigrid iteration for the nonsymmetric and/or indefinite problem is shown to converge at a uniform rate provided that the coarsest grid in the multilevel iteration is sufficiently fine (but not depending on the number of multigrid levels).

  20. Elimination of the asymmetric modes in a Ka-band super overmoded coaxial Cerenkov oscillator

    NASA Astrophysics Data System (ADS)

    Bai, Zhen; Zhang, Jun; Zhong, Huihuang; Zhao, Xuelong; Yang, Fuxiang

    2017-12-01

    The issue of asymmetric modes output of a Ka-band super overmoded coaxial Cerenkov oscillator is analyzed in this paper. Due to serious passband overlapping in a super overmoded coaxial slow wave structure (SWS), the asymmetric competition mode EH11 can hardly be suppressed thoroughly by the methods adopted in moderately overmoded devices, especially in the startup of oscillation. If the output structures reflect the asymmetric modes, the asymmetric mode competition in SWS will be aggravated and the normal operation state will be destroyed. In order to solve this problem, a taper waveguide is inserted at a specific position to achieve the destructive interference of the reflected TM11, and a special support structure is designed to avoid reflection of TE11. With these methods, asymmetric mode competition can be successfully eliminated, and the oscillator is capable of achieving a steady fundamental mode operation performance.

  1. Pump impeller

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wickoren, D.R.

    1990-02-27

    This patent describes an impeller for pumping highly viscous liquids. It comprises: a substantially circular drive plate having first and second sides, a geometric center, and a marginal edge. The drive plate being adapted for rotation within a pump housing; a plurality of symmetrical, evenly spaced blades extending radially outwardly to present a tip. Each of the blades being connected only to the drive plate and extending substantially normal thereto to present a sharpened top edge opposite the drive plate. Each of the blades including a leading face corresponding to the direction of rotation of the impeller during operation andmore » a trailing face oriented away from a direction of rotation of the impeller during operation thereof. Each of the blades including winglet means secured to the leading face thereof and located intermediate aid top edge and the drive plate and positioned more proximate to the top edge than to the drive plate.« less

  2. The Role of Cervical and Ocular Vestibular Evoked Myogenic Potentials in the Assessment of Patients with Vestibular Schwannomas

    PubMed Central

    Chiarovano, Elodie; Darlington, Cynthia; Vidal, Pierre-Paul; Lamas, Georges; de Waele, Catherine

    2014-01-01

    Objectives To investigate the clinical utility of VEMPs in patients suffering from unilateral vestibular schwannoma (VS) and to determine the optimal stimulation parameter (air conducted sound, bone conducted vibration) for evaluating the function of the vestibular nerve. Methods Data were obtained in 63 patients with non-operated VS, and 20 patients operated on VS. Vestibular function was assessed by caloric, cervical and ocular VEMP testing. 37/63 patients with conclusive ACS ocular VEMPs responses were studied separately. Results In the 63 non-operated VS patients, cVEMPs were abnormal in 65.1% of patients in response to AC STB and in 49.2% of patients to AC clicks. In the 37/63 patients with positive responses from the unaffected side, oVEMPs were abnormal in 75.7% of patients with ACS, in 67.6% with AFz and in 56.8% with mastoid BCV stimulation. In 16% of the patients, VEMPs were the only abnormal test (normal caloric and normal hearing). Among the 26 patients who did not show oVEMP responses on either side with ACS, oVEMPs responses could be obtained with AFz (50%) and with mastoid stimulation (89%). Conclusions The VEMP test demonstrated significant clinical value as it yielded the only abnormal test results in some patients suffering from a unilateral vestibular schwannoma. For oVEMPs, we suggest that ACS stimulation should be the initial test. In patients who responded to ACS and who had normal responses, BCV was not required. In patients with abnormal responses on the affected side using ACS, BCV at AFz should be used to confirm abnormal function of the superior vestibular nerve. In patients who exhibited no responses on either side to ACS, BCV was the only approach allowing assessment of the function of the superior vestibular nerve. We favor using AFz stimulation first because it is easier to perform in clinical practice than mastoid stimulation. PMID:25137289

  3. Semi-automated extraction of longitudinal subglacial bedforms from digital terrain models - Two new methods

    NASA Astrophysics Data System (ADS)

    Jorge, Marco G.; Brennand, Tracy A.

    2017-07-01

    Relict drumlin and mega-scale glacial lineation (positive relief, longitudinal subglacial bedforms - LSBs) morphometry has been used as a proxy for paleo ice-sheet dynamics. LSB morphometric inventories have relied on manual mapping, which is slow and subjective and thus potentially difficult to reproduce. Automated methods are faster and reproducible, but previous methods for LSB semi-automated mapping have not been highly successful. Here, two new object-based methods for the semi-automated extraction of LSBs (footprints) from digital terrain models are compared in a test area in the Puget Lowland, Washington, USA. As segmentation procedures to create LSB-candidate objects, the normalized closed contour method relies on the contouring of a normalized local relief model addressing LSBs on slopes, and the landform elements mask method relies on the classification of landform elements derived from the digital terrain model. For identifying which LSB-candidate objects correspond to LSBs, both methods use the same LSB operational definition: a ruleset encapsulating expert knowledge, published morphometric data, and the morphometric range of LSBs in the study area. The normalized closed contour method was separately applied to four different local relief models, two computed in moving windows and two hydrology-based. Overall, the normalized closed contour method outperformed the landform elements mask method. The normalized closed contour method performed on a hydrological relief model from a multiple direction flow routing algorithm performed best. For an assessment of its transferability, the normalized closed contour method was evaluated on a second area, the Chautauqua drumlin field, Pennsylvania and New York, USA where it performed better than in the Puget Lowland. A broad comparison to previous methods suggests that the normalized relief closed contour method may be the most capable method to date, but more development is required.

  4. Research on Pin Tumbler Locks and the Characteristics of Surface Traces Formed by Unlocking Guns

    NASA Astrophysics Data System (ADS)

    Yi, Gao; Yifeng, Jin; Yanping, Bai; Hongcheng, Mei; Zhen, Xu

    2018-02-01

    In this paper, taking the structure of the pin tumbler locks and the principle of opening and closing locks as breakthrough point, we have studied the machining traces of pin tumbler components and trace characters of pin surface during normal operating. At the same time, taking the unlocking gun as an example, the paper analyzes the unlocking technology and the formation of traces, and summarizes the changing rules of the surface traces of elastic bead locks by comparing the positions and the characteristics of the traces, which provides technical support for the future study of traces of pin tumbler locks.

  5. Optimal quantum observables

    NASA Astrophysics Data System (ADS)

    Haapasalo, Erkka; Pellonpää, Juha-Pekka

    2017-12-01

    Various forms of optimality for quantum observables described as normalized positive-operator-valued measures (POVMs) are studied in this paper. We give characterizations for observables that determine the values of the measured quantity with probabilistic certainty or a state of the system before or after the measurement. We investigate observables that are free from noise caused by classical post-processing, mixing, or pre-processing of quantum nature. Especially, a complete characterization of pre-processing and post-processing clean observables is given, and necessary and sufficient conditions are imposed on informationally complete POVMs within the set of pure states. We also discuss joint and sequential measurements of optimal quantum observables.

  6. High resolution particle tracking method by suppressing the wavefront aberrations

    NASA Astrophysics Data System (ADS)

    Chang, Xinyu; Yang, Yuan; Kou, Li; Jin, Lei; Lu, Junsheng; Hu, Xiaodong

    2018-01-01

    Digital in-line holographic microscopy is one of the most efficient methods for particle tracking as it can precisely measure the axial position of particles. However, imaging systems are often limited by detector noise, image distortions and human operator misjudgment making the particles hard to locate. A general method is used to solve this problem. The normalized holograms of particles were reconstructed to the pupil plane and then fit to a linear superposition of the Zernike polynomial functions to suppress the aberrations. Relative experiments were implemented to validate the method and the results show that nanometer scale resolution was achieved even when the holograms were poorly recorded.

  7. MicroRNA array normalization: an evaluation using a randomized dataset as the benchmark.

    PubMed

    Qin, Li-Xuan; Zhou, Qin

    2014-01-01

    MicroRNA arrays possess a number of unique data features that challenge the assumption key to many normalization methods. We assessed the performance of existing normalization methods using two microRNA array datasets derived from the same set of tumor samples: one dataset was generated using a blocked randomization design when assigning arrays to samples and hence was free of confounding array effects; the second dataset was generated without blocking or randomization and exhibited array effects. The randomized dataset was assessed for differential expression between two tumor groups and treated as the benchmark. The non-randomized dataset was assessed for differential expression after normalization and compared against the benchmark. Normalization improved the true positive rate significantly in the non-randomized data but still possessed a false discovery rate as high as 50%. Adding a batch adjustment step before normalization further reduced the number of false positive markers while maintaining a similar number of true positive markers, which resulted in a false discovery rate of 32% to 48%, depending on the specific normalization method. We concluded the paper with some insights on possible causes of false discoveries to shed light on how to improve normalization for microRNA arrays.

  8. MicroRNA Array Normalization: An Evaluation Using a Randomized Dataset as the Benchmark

    PubMed Central

    Qin, Li-Xuan; Zhou, Qin

    2014-01-01

    MicroRNA arrays possess a number of unique data features that challenge the assumption key to many normalization methods. We assessed the performance of existing normalization methods using two microRNA array datasets derived from the same set of tumor samples: one dataset was generated using a blocked randomization design when assigning arrays to samples and hence was free of confounding array effects; the second dataset was generated without blocking or randomization and exhibited array effects. The randomized dataset was assessed for differential expression between two tumor groups and treated as the benchmark. The non-randomized dataset was assessed for differential expression after normalization and compared against the benchmark. Normalization improved the true positive rate significantly in the non-randomized data but still possessed a false discovery rate as high as 50%. Adding a batch adjustment step before normalization further reduced the number of false positive markers while maintaining a similar number of true positive markers, which resulted in a false discovery rate of 32% to 48%, depending on the specific normalization method. We concluded the paper with some insights on possible causes of false discoveries to shed light on how to improve normalization for microRNA arrays. PMID:24905456

  9. Comparative study of cluster Ag17Cu2 by instantaneous normal mode analysis and by isothermal Brownian-type molecular dynamics simulation.

    PubMed

    Tang, Ping-Han; Wu, Ten-Ming; Yen, Tsung-Wen; Lai, S K; Hsu, P J

    2011-09-07

    We perform isothermal Brownian-type molecular dynamics simulations to obtain the velocity autocorrelation function and its time Fourier-transformed power spectral density for the metallic cluster Ag(17)Cu(2). The temperature dependences of these dynamical quantities from T = 0 to 1500 K were examined and across this temperature range the cluster melting temperature T(m), which we define to be the principal maximum position of the specific heat is determined. The instantaneous normal mode analysis is then used to dissect the cluster dynamics by calculating the vibrational instantaneous normal mode density of states and hence its frequency integrated value I(j) which is an ensemble average of all vibrational projection operators for the jth atom in the cluster. In addition to comparing the results with simulation data, we look more closely at the entities I(j) of all atoms using the point group symmetry and diagnose their temperature variations. We find that I(j) exhibit features that may be used to deduce T(m), which turns out to agree very well with those inferred from the power spectral density and specific heat. © 2011 American Institute of Physics

  10. Depressed mood, positive affect, and heart rate variability in patients with suspected coronary artery disease.

    PubMed

    Bhattacharyya, Mimi R; Whitehead, Daisy L; Rakhit, Roby; Steptoe, Andrew

    2008-11-01

    To test associations between heart rate variability (HRV), depressed mood, and positive affect in patients with suspected coronary artery disease (CAD). Depression is associated with impaired HRV post acute cardiac events, but evidence in patients with stable coronary artery disease (CAD) is inconsistent. Seventy-six patients (52 men, 24 women; mean age = 61.1 years) being investigated for suspected CAD on the basis of symptomatology and positive noninvasive tests, completed 24-hour electrocardiograms. The Beck Depression Inventory (BDI) was administered, and positive and depressed affect was measured over the study period with the Day Reconstruction Method (DRM). A total of 46 (60.5%) patients were later found to have definite CAD. HRV was analyzed, using spectral analysis. Typical diurnal profiles of HRV were observed, with greater normalized high frequency (HF) and lower normalized low frequency (LF) power in the night compared with the day. BDI depression scores were not consistently associated with HRV. But positive affect was associated with greater normalized HF power (p = .039) and reduced normalized LF power (p = .007) independently of age, gender, medication with beta blockers, CAD status, body mass index, smoking, and habitual physical activity level. In patients with definite CAD, depressed affect assessed using the DRM was associated with reduced normalized HF power and heightened normalized LF power (p = .007) independently of covariates. Relationships between depression and HRV in patients with CAD may depend on affective experience over the monitoring period. Enhanced parasympathetic cardiac control may be a process through which positive affect protects against cardiovascular disease.

  11. RADIATION FACILITY FOR NUCLEAR REACTORS

    DOEpatents

    Currier, E.L. Jr.; Nicklas, J.H.

    1961-12-12

    A radiation facility is designed for irradiating samples in close proximity to the core of a nuclear reactor. The facility comprises essentially a tubular member extending through the biological shield of the reactor and containing a manipulatable rod having the sample carrier at its inner end, the carrier being longitudinally movable from a position in close proximity to the reactor core to a position between the inner and outer faces of the shield. Shield plugs are provided within the tubular member to prevent direct radiation from the core emanating therethrough. In this device, samples may be inserted or removed during normal operation of the reactor without exposing personnel to direct radiation from the reactor core. A storage chamber is also provided within the radiation facility to contain an irradiated sample during the period of time required to reduce the radioactivity enough to permit removal of the sample for external handling. (AEC)

  12. An automated BPM characterization system for LEDA

    NASA Astrophysics Data System (ADS)

    Shurter, R. B.; Gilpatrick, J. D.; Ledford, J.; O'Hara, J.; Power, J.

    1998-12-01

    An automated and highly accurate system for "mapping" 5 cm-diameter beam position monitors (BPMs) used in the Low Energy Demonstrator Accelerator (LEDA) at Los Alamos is described. Two-dimensional data is accumulated from the four micro-stripline electrodes in the probe by sweeping an antenna driven at the LEDA bunching frequency of 350 MHz in discrete steps across the aperture. These data are then used to determine the centroid, first- and third-order sensitivities of the BPM. These probe response coefficients are then embedded in the LEDA control system database to provide normalized beam position information to the operators. A short summary of previous systems we have fielded is given, along with their attributes and deficiencies that had a bearing on this latest design. Lessons learned from this system will, in turn, be used on the next mappers that are currently being designed for 15 cm and 2.5 cm BPMs.

  13. A button - type beam position monitor design for TARLA facility

    NASA Astrophysics Data System (ADS)

    Gündoǧan, M. Tural; Kaya, ć.; Yavaş, Ö.

    2016-03-01

    Turkish Accelerator and Radiation Laboratory in Ankara (TARLA) facility is proposed as an IR FEL and Bremsstrahlung facility as the first facility of Turkish Accelerator Center (TAC). TARLA is essentially proposed to generate oscillator mode FEL in 3-250 microns wavelengths range, will consist of normal conducting injector system with 250 keV beam energy, two superconducting RF accelerating modules in order to accelerate the beam 15-40 MeV. The TARLA facility is expected to provide two modes, Continuous wave (CW) and pulsed mode. Longitudinal electron bunch length will be changed between 1 and 10 ps. The bunch charge will be limited by 77pC. The design of the Button-type Beam Position Monitor for TARLA IR FEL is studied to operate in 1.3 GHz. Mechanical antenna design and simulations are completed considering electron beam parameters of TARLA. Ansoft HFSS and CST Particle Studio is used to compare with results of simulations.

  14. Six degree-of-freedom scanning supports and manipulators based on parallel robots

    NASA Astrophysics Data System (ADS)

    Comin, Fabio

    1995-02-01

    The exploitation of third generation SR sources heavily relies on accurate and stable positioning and scanning of samples and optical elements. In some cases, active feedback is also necessary. Normally, these tasks are carried out by serial addition of individual components, each of them providing a well-defined excursion path. On the contrary, the exploitation of the concept of parallel robots, structures in close cinematic chain, permits us to follow any given trajectory in the six-dimensional space with a large increase in accuracy and stiffness. At ESRF, the parallel robot architecture conceived some tens of years ago for flight simulators has been adapted to both actively align and operate optical elements of considerable weight and position small samples in ultrahigh vacuum. The performance of these devices gives results far superior to the initial specification and a variety of drive mechanisms are being developed to fit the different needs of the ESRF beamlines.

  15. Estrogen and progesterone receptors in normal cervix and primary cervical carcinoma.

    PubMed

    Shen, K; Yueng, W; Ngan, H

    1994-09-01

    Estrogen and progesterone receptors (ER, PR) were measured in 21 specimens of cervical cancer and in 17 specimens of normal cervix by monoclonal enzyme immunoassay (EIA). In normal cervix, 88.2% of specimens were ER-positive ( > 15 fmol/mg protein), 74.5% were PR-positive ( > 15 fmol/mg protein) and 74.5% were both ER- and PR-positive. In cervical cancer, 66.7% were ER-positive, 42.9% were PR-positive and 38.1% were both ER- and PR- positive. There was no significant difference in ER status between the normal cervix and cervical cancer (P > 0.05), but PR status and levels in normal cervix were significantly higher than those in cervical carcinoma (P < 0.05). ER levels in squamous cell carcinoma was not correlated to the tumor stage, histologic grade and menopausal status. PR levels in premenopausal patients with squamous cell carcinoma were significantly higher than those in postmenopausal patients (P < 0.01). Adenocarcinoma of the cervix contained significantly more ER and PR than squamous cell carcinoma (P < 0.01, P < 0.05). In addition, serum E2 level was also assayed in 21 patients with cervical cancer. There was significant difference in E2 levels between the premenopausal and postmenopausal patients (P < 0.01). Patients were stratified according to E2 levels, a significant difference in PR levels and in the ratio of PR/ER was noted (P < 0.05, P < 0.01).

  16. 28 CFR 42.712 - Exception; normal operation or statutory objective.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... objective. 42.712 Section 42.712 Judicial Administration DEPARTMENT OF JUSTICE NONDISCRIMINATION; EQUAL... Programs or Activities; Implementation of the Age Discrimination Act of 1975 Standards for Determining Age Discrimination § 42.712 Exception; normal operation or statutory objective. (a) A recipient may take an action...

  17. Human papillomavirus in normal conjunctival tissue and in conjunctival papilloma: types and frequencies in a large series.

    PubMed

    Sjö, Nicolai Christian; von Buchwald, Christian; Cassonnet, Patricia; Norrild, Bodil; Prause, Jan Ulrik; Vinding, Troels; Heegaard, Steffen

    2007-08-01

    To examine conjunctival papilloma and normal conjunctival tissue for the presence of human papillomavirus (HPV). Archival paraffin wax-embedded tissue from 165 conjunctival papillomas and from 20 histological normal conjunctival biopsy specimens was analysed for the presence of HPV by PCR. Specimens considered HPV positive using consensus primers, but with a negative or uncertain PCR result using type-specific HPV probes, were analysed with DNA sequencing. HPV was present in 86 of 106 (81%) beta-globin-positive papillomas. HPV type 6 was positive in 80 cases, HPV type 11 was identified in 5 cases and HPV type 45 was present in a single papilloma. All the 20 normal conjunctival biopsy specimens were beta-globin positive and HPV negative. There is a strong association between HPV and conjunctival papilloma. The study presents the largest material of conjunctival papilloma investigated for HPV and the first investigation of HPV in normal conjunctival tissue. HPV types 6 and 11 are the most common HPV types in conjunctival papilloma. This also is the first report of HPV type 45 in conjunctival papilloma.

  18. Apparatus and method for selectively channeling a fluid

    DOEpatents

    Rightley, Michael Joseph [Albuquerque, NM

    2008-01-01

    An apparatus for selectively channeling a high temperature fluid without chemically reacting with the fluid. The apparatus includes an inlet and a membrane positioned adjacent to the inlet, each composed of a chemically inert material. The membrane is formed by compressive preloading techniques. The apparatus further includes a seat disposed on the inlet adjacent to the membrane. The seat is composed of a heat resistant and chemically inert material. Operation of the apparatus requires that the temperature of the fluid remains below the chemical characteristic melting point of the seat. The apparatus further includes an actuator coupled to the membrane for rendering the membrane in an open and a closed position with respect to the seat. Specifically, the actuator supplies a load in the normal direction to the membrane to selectively engage the membrane in a plurality of predetermined configurations. Operatively, the apparatus receives the fluid at the inlet. The fluid is received at a high temperature and is directed from the inlet to the membrane. In the closed position, the actuator engages the membrane to prevent the fluid from flowing from the inlet between the membrane and the seat. Alternatively, in the open position, the actuator engages the membrane to permit fluid flow from the inlet between the membrane and the seat to at least one outlet provided by the apparatus. In one exemplary embodiment, the fluid may be discharged from the at least one outlet to a sensor in fluid communication with the at least one outlet. Accordingly, the sensor may measure the fluid channeled through the heat resistant and chemically inert environment provided by the apparatus.

  19. Prevalence of Colour Vision Anomalies Amongst Dental Professionals and its Effect on Shade Matching of Teeth.

    PubMed

    Khosla, Amrit; Maini, Anuj Paul; Wangoo, Anuj; Singh, Sukhman; Mehar, Damanpreet Kaur

    2017-01-01

    The success of a restoration is dependent on accurate shade matching of teeth leading to studies evaluating the factors affecting the perception of shades. Colour vision anomalies including colour blindness have been found to exist in the population and it has been thought to be a potential factor affecting the colour perception ability. The present study was done to evaluate the prevalence of colour vision anomalies and its effect on matching of shades of teeth. A total of 147 dental professionals were randomly selected for the study and were first tested for visual acuity using the Snellen's Eye Chart so as to carry on the study with only those operators who had a vision of 6/6. Then, the Ishihara's colour charts were used to test the operators for colour vision handicap. In the last stage of the study, test for accuracy of shade selection was done using the Vitapan Classical shade guide. The shade guide tabs were covered to avoid bias. Percentage was used to calculate the prevalence of colour vision handicap and its effect on matching of shades of teeth as compared to normal vision, which was evaluated using Chi square test. Nineteen operators had colour vision anomalies out of hundred operators and only two operators presented with colour blindness. Colour vision anomaly was more prevalent than colour blindness and it was also found that it was more prevalent in males than females. The difference between the accuracy of shade matching between the operators with normal vision and colour vision defect and operators with normal vision and colour blindness was statistically not significant. Colour blindness and colour vision handicap are rare conditions, with the latter being more common in the population. According to our study, it was concluded that no statistically significant difference existed amongst the operators with normal vision and colour vision anomaly or operators with normal vision and colour blindness during the matching of shades of teeth.

  20. Relationship between Topoisomerase 2A RNA Expression and Recurrence after Adjuvant Chemotherapy for Breast Cancer.

    PubMed

    Sparano, Joseph A; Goldstein, Lori J; Childs, Barrett H; Shak, Steven; Brassard, Diana; Badve, Sunil; Baehner, Frederick L; Bugarini, Roberto; Rowley, Steve; Perez, Edith; Shulman, Lawrence N; Martino, Silvana; Davidson, Nancy E; Sledge, George W; Gray, Robert

    2009-12-15

    PURPOSE: To perform an exploratory analysis of the relationship between gene expression and recurrence in operable hormone receptor (HR)-positive, human epidermal growth factor receptor 2 (HER2)-normal breast cancer patients treated with adjuvant doxorubicin-containing chemotherapy. EXPERIMENTAL DESIGN: RNA was extracted from archived tumor samples derived from 378 patients with stage I to III HR-positive, HER2-normal breast cancer and analyzed by reverse transcription-PCR for a panel of 374 genes, including the 21-gene recurrence score (RS). Patients were randomized to receive adjuvant doxorubicin plus cyclophosphamide or docetaxel in trial E2197, with no difference in recurrence seen in the treatment arms. All available recurrent cases were selected plus a nonrecurrent cohort. Cox proportional hazard models were used to identify relationships between gene expression and recurrence. RESULTS: TOP2A expression exhibited the strongest association with increased recurrence risk (P = 0.01), and was significantly associated with recurrence (P = 0.008) in a multivariate analysis adjusted for clinicopathologic features. Elevated TOP2A expression above the median was associated with a 2.6-fold increase (95% confidence interval, 1.3-5.2; P = 0.008) in risk of recurrence if the RS was <18, and a 2.0-fold increase (95% confidence interval, 1.2-3.2, P = 0.003) if there was an intermediate RS of 18 to 30. CONCLUSIONS: In patients with HR-positive, HER2-normal breast cancer, a population known to have a low incidence of TOP2A gene alterations thought to be predictive of anthracycline benefit, there is a range of TOP2A RNA expression that is strongly associated with recurrence after adjuvant anthracyclines, which provides information complementary to RS, indicating that it merits further evaluation as a prognostic and predictive marker. (Clin Cancer Res 2009;15(24):7693-700).

  1. Real-time simulator for helicopter rotor wind-tunnel operations

    NASA Technical Reports Server (NTRS)

    Talbot, P. D.; Peterson, R. L.; Graham, D. R.

    1986-01-01

    This paper describes the elements and operation of a simulator that is being used to train operators of the Rotor Test Apparatus (RTA) in the large-scale 40- by 80-Foot Wind Tunnel at Ames Research Center. The simulator, named TUTOR (for Tunnel Utilization Trainer with Operating Rotor) duplicates the controls of the rotor and its dynamic behavior, as well as the wind-tunnel controls. The simulation software uses a preexisting blade-element model of a four-bladed rotor with flapping and lead-lag degrees of freedom. Equations were developed for all hardware and controls of the RTA and of the wind tunnel that are normally required to perform a wind-tunnel test of a helicopter rotor. The simulator hardware consists of consoles designed to have the same appearance and functions as those in the control room of the 40- by 80-Foot Wind Tunnel, allowing input from three operators who normally establish the required operating conditions during a test run. Normal operating procedures can be practiced, as well as simulated emergencies such as rotor power failure.

  2. Normalization as a canonical neural computation

    PubMed Central

    Carandini, Matteo; Heeger, David J.

    2012-01-01

    There is increasing evidence that the brain relies on a set of canonical neural computations, repeating them across brain regions and modalities to apply similar operations to different problems. A promising candidate for such a computation is normalization, in which the responses of neurons are divided by a common factor that typically includes the summed activity of a pool of neurons. Normalization was developed to explain responses in the primary visual cortex and is now thought to operate throughout the visual system, and in many other sensory modalities and brain regions. Normalization may underlie operations such as the representation of odours, the modulatory effects of visual attention, the encoding of value and the integration of multisensory information. Its presence in such a diversity of neural systems in multiple species, from invertebrates to mammals, suggests that it serves as a canonical neural computation. PMID:22108672

  3. Does the optimal position of the acetabular fragment should be within the radiological normal range for all developmental dysplasia of the hip? A patient-specific finite element analysis.

    PubMed

    Wang, Xuyi; Peng, Jianping; Li, De; Zhang, Linlin; Wang, Hui; Jiang, Leisheng; Chen, Xiaodong

    2016-10-04

    The success of Bernese periacetabular osteotomy depends significantly on how extent the acetabular fragment can be corrected to its optimal position. This study was undertaken to investigate whether correcting the acetabular fragment into the so-called radiological "normal" range is the best choice for all developmental dysplasia of the hip with different severities of dysplasia from the biomechanical view? If not, is there any correlation between the biomechanically optimal position of the acetabular fragment and the severity of dysplasia? Four finite element models with different severities of dysplasia were developed. The virtual periacetabular osteotomy was performed with the acetabular fragment rotated anterolaterally to incremental center-edge angles; then, the contact area and pressure and von Mises stress in the cartilage were calculated at different correction angles. The optimal position of the acetabular fragment for patients 1, 2, and 3 was when the acetabular fragment rotated 17° laterally (with the lateral center-edge angle of 36° and anterior center-edge angle of 58°; both were slightly larger than the "normal" range), 25° laterally following further 5° anterior rotation (with the lateral center-edge angle of 31° and anterior center-edge angle of 51°; both were within the "normal" range), and 30° laterally following further 10° anterior rotation (with the lateral center-edge angle of 25° and anterior center-edge angle of 40°; both were less than the "normal" range), respectively. The optimal corrective position of the acetabular fragment is severity dependent rather than within the radiological "normal" range for developmental dysplasia of the hip. We prudently proposed that the optimal correction center-edge angle of mild, moderate, and severe developmental dysplasia of the hip is slightly larger than the "normal" range, within the "normal" range, and less than the lower limit of the "normal" range, respectively.

  4. On Nth roots of positive operators

    NASA Technical Reports Server (NTRS)

    Brown, D. R.; Omalley, M. J.

    1978-01-01

    A bounded operator A on a Hilbert space H was positive. These operators were symmetric, and as such constitute a natural generalization of nonnegative real diagonal matrices. The following result is thus both well known and not surprising: A positive operator has a unique positive square root (under operator composition).

  5. [MINIMALLY INVASIVE TREATMENT OF POSTERIOR CRUCIATE LIGAMENT AVULSION FRACTURE IN A FLOPPY LATERAL POSITION].

    PubMed

    Zhao, Junchao; Wang, Hao

    2016-09-08

    To conclude the effectiveness of arthroscopy combined with Burks and SchaVer's approach in the treatment of posterior cruciate ligament (PCL) avulsion fractures in a floppy lateral position. Between May 2010 and March 2014, 21 patients with PCL avulsion fractures were treated. There were 13 males and 8 females, aged 21 to 62 years (mean, 39.1 years). The causes included traffic accident injury in 10 cases, sports injury in 5 cases, and falling injury from height in 6 cases. The time from injury to hospital was 1-6 days (mean, 2.5 days). The results of posterior drawer test were all positive, and the results of anterior drawer test and lateral stress test were all negative. The Lysholm score was 28.0±5.5 before operation. And the American Orthopaedic Foot and Ankle Society (IKDC) score was 46.2±7.6 before operation. According to Meyer standards for fractures classification, 11 cases were rated as type II and 10 cases as type III. Arthroscopy was used to inspect and treat the intra-articular lesions, then avulsion fracture was fixed by Burks and SchaVer's approach in lateral position. Postoperative functional exercises were performed. Primary healing of incision was obtained, without nerve and vascular injury or joint infection. All patients were followed up 18-36 months (mean, 27.2 months). The X-ray films of the knee joint showed good fractures reduction and healing at 3 months after operation. The results of posterior drawer test and reverse Lachman test were negative. The knee range of motion was recovered to normal level. At last follow-up, the Lysholm score of the knee joint was significantly improved to 90.9±1.4 from preoperative one ( t =54.584, P =0.000), and the IKDC score was significantly increased to 90.5±5.3 from preoperative one ( t =15.638, P =0.000), including 19 cases of grade A and 2 cases of grade B. A combination of arthroscopy and Burks and SchaVer's approach for the treatment of PCL avulsion fractures in a floppy lateral position has the advantages of minimal invasion and safe approach, short operative time, and early postoperative rehabilitation exercises, so it can provide satisfactory function recovery of the knee joint.

  6. An order insertion scheduling model of logistics service supply chain considering capacity and time factors.

    PubMed

    Liu, Weihua; Yang, Yi; Wang, Shuqing; Liu, Yang

    2014-01-01

    Order insertion often occurs in the scheduling process of logistics service supply chain (LSSC), which disturbs normal time scheduling especially in the environment of mass customization logistics service. This study analyses order similarity coefficient and order insertion operation process and then establishes an order insertion scheduling model of LSSC with service capacity and time factors considered. This model aims to minimize the average unit volume operation cost of logistics service integrator and maximize the average satisfaction degree of functional logistics service providers. In order to verify the viability and effectiveness of our model, a specific example is numerically analyzed. Some interesting conclusions are obtained. First, along with the increase of completion time delay coefficient permitted by customers, the possible inserting order volume first increases and then trends to be stable. Second, supply chain performance reaches the best when the volume of inserting order is equal to the surplus volume of the normal operation capacity in mass service process. Third, the larger the normal operation capacity in mass service process is, the bigger the possible inserting order's volume will be. Moreover, compared to increasing the completion time delay coefficient, improving the normal operation capacity of mass service process is more useful.

  7. Modelling physiological deterioration in post-operative patient vital-sign data.

    PubMed

    Pimentel, Marco A F; Clifton, David A; Clifton, Lei; Watkinson, Peter J; Tarassenko, Lionel

    2013-08-01

    Patients who undergo upper-gastrointestinal surgery have a high incidence of post-operative complications, often requiring admission to the intensive care unit several days after surgery. A dataset comprising observational vital-sign data from 171 post-operative patients taking part in a two-phase clinical trial at the Oxford Cancer Centre, was used to explore the trajectory of patients' vital-sign changes during their stay in the post-operative ward using both univariate and multivariate analyses. A model of normality based vital-sign data from patients who had a "normal" recovery was constructed using a kernel density estimate, and tested with "abnormal" data from patients who deteriorated sufficiently to be re-admitted to the intensive care unit. The vital-sign distributions from "normal" patients were found to vary over time from admission to the post-operative ward to their discharge home, but no significant changes in their distributions were observed from halfway through their stay on the ward to the time of discharge. The model of normality identified patient deterioration when tested with unseen "abnormal" data, suggesting that such techniques may be used to provide early warning of adverse physiological events.

  8. 7 CFR 701.23 - Eligible costs.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... as follows: (1) Costs for use of personal equipment shall be limited to those incurred beyond the normal operation of the eligible land. (2) Costs for personal labor shall be limited to personal labor not normally required in the operation of the eligible land. (3) Costs for the use of personal...

  9. 76 FR 36864 - Special Conditions: Gulfstream Model GVI Airplane; Operation Without Normal Electric Power

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-06-23

    ... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration 14 CFR Part 25 [Docket No. NM444; Special Conditions No. 25-435-SC] Special Conditions: Gulfstream Model GVI Airplane; Operation Without... rules (VFR) conditions for at least five minutes after loss of all normal electrical power. This rule...

  10. 78 FR 66002 - Revised Filing Deadlines Following Resumption of Normal Commission Operations

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-11-04

    ... FEDERAL COMMUNICATIONS COMMISSION [DA 13-2025; WC Docket No. 05-337; IB Docket No. 13-230; WT... Resumption of Normal Commission Operations AGENCY: Federal Communications Commission. ACTION: Notice; revised... Communications, Inc.; Petition for Declaratory Ruling under Section 310(b)(4) of the Communications Act, as...

  11. 9 CFR 311.23 - Tapeworm cysts (cysticercus bovis) in cattle.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... OF AGRICULTURE AGENCY ORGANIZATION AND TERMINOLOGY; MANDATORY MEAT AND POULTRY PRODUCTS INSPECTION... exposed during normal dressing operations, they are found in at least two of the sites exposed by (i) an..., esophagus, tongue, and musculature exposed during normal dressing operations, may be passed for human food...

  12. 22 CFR 1411.3 - Information policy.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ..., respectively, and at reasonable times during normal working hours so long as it does not interfere with the... working hours so long as it does not interfere with the efficient operations of the Authority, the Board... during normal working hours so long as it does not interfere with the efficient operations of the...

  13. Mutants of Arabidopsis thaliana with altered phototropism

    NASA Technical Reports Server (NTRS)

    Khurana, J. P.; Poff, K. L.

    1989-01-01

    Thirty five strains of Arabidopsis thaliana (L.) Heynh. have been identified with altered phototropic responses to 450-nm light. Four of these mutants have been more thoroughly characterized. Strain JK224 shows normal gravitropism and "second positive" phototropism. However, while the amplitude for "first positive" phototropism is the same as that in the wild-type, the threshold and fluence for the maximum response in "first positive" phototropism are shifted to higher fluence by a factor of 20-30. This mutant may represent an alteration in the photoreceptor pigment for phototropism. Strain JK218 exhibits no curvature to light at any fluence from 1 micromole m-2 to 2700 micromoles m-2, but shows normal gravitropism. Strain JK345 shows no "first positive" phototropism, and reduced gravitropism and "second positive" phototropism. Strain JK229 shows no measurable "first positive" phototropism, but normal gravitropism and "second positive" phototropism. Based on these data, it is suggested that: 1. gravitropism and phototropism contain at least one common element; 2. "first positive" and "second positive" phototropism contain at least one common element; and 3. "first positive" phototropism can be substantially altered without any apparent alteration of "second positive" phototropism.

  14. The significance of early post-exercise ST segment normalization.

    PubMed

    Chow, Rudy; Fordyce, Christopher B; Gao, Min; Chan, Sammy; Gin, Kenneth; Bennett, Matthew

    2015-01-01

    The persistence of ST segment depression in recovery signifies a strongly positive exercise treadmill test (ETT). However, it is unclear if early recovery of ST segments portends a similar prognosis. We sought to determine if persistence of ST depression into recovery correlates with ischemic burden based on myocardial perfusion imaging (MPI). This was a retrospective analysis of 853 consecutive patients referred for exercise MPI at a tertiary academic center over a 24-month period. Patients were stratified into three groups based on the results of the ETT: normal (negative ETT), persistence (positive ETT with >1mm ST segment depression at 1minute in recovery) and early normalization (positive ETT with <1mm ST segment depression at 1minute in recovery). Summed stress scores (SSSs) were calculated then for each patient, while the coronary anatomy was reported for the subset of patients who received coronary angiograms. A total of 513 patients had a negative ETT, 235 patients met criteria for early normalization, while 105 patients met criteria for persistence. The persistence group had a significantly greater SSS (8.48±7.77) than both the early normalization (4.34±4.98, p<0.001) and normal (4.47±5.31, p<0.001) groups. The SSSs of the early normalization and normal groups were not statistically different and met the prespecified non-inferiority margin (mean difference 0.12, -0.66=lower 95% CI, p<0.001). Among the 87 patients who underwent an angiogram, significant three-vessel or left main disease was seen in 39.3% of the persistence group compared with 5.9% of normal and 7.4% of early normalization groups. Among patients with an electrically positive ETT, recovery of ST segment depression within 1minute was associated with a lower SSS than patients with persistence of ST depression beyond 1minute. Furthermore, early ST segment recovery conferred a similar SSS to patients with a negative ETT. These results suggest that among patients evaluated for chest pain with a positive ETT, early recovery of the ST segment during recovery is associated with a significantly less ischemic burden on subsequent MPI and thus may represent a false positive finding in exercise treadmill testing. Copyright © 2015 Elsevier Inc. All rights reserved.

  15. Cis-Lunar Base Camp

    NASA Technical Reports Server (NTRS)

    Merrill, Raymond G.; Goodliff, Kandyce E.; Mazanek, Daniel D.; Reeves, John D., Jr.

    2012-01-01

    Historically, when mounting expeditions into uncharted territories, explorers have established strategically positioned base camps to pre-position required equipment and consumables. These base camps are secure, safe positions from which expeditions can depart when conditions are favorable, at which technology and operations can be tested and validated, and facilitate timely access to more robust facilities in the event of an emergency. For human exploration missions into deep space, cis-lunar space is well suited to serve as such a base camp. The outer regions of cis-lunar space, such as the Earth-Moon Lagrange points, lie near the edge of Earth s gravity well, allowing equipment and consumables to be aggregated with easy access to deep space and to the lunar surface, as well as more distant destinations, such as near-Earth Asteroids (NEAs) and Mars and its moons. Several approaches to utilizing a cis-lunar base camp for sustainable human exploration, as well as some possible future applications are identified. The primary objective of the analysis presented in this paper is to identify options, show the macro trends, and provide information that can be used as a basis for more detailed mission development. Compared within are the high-level performance and cost of 15 preliminary cis-lunar exploration campaigns that establish the capability to conduct crewed missions of up to one year in duration, and then aggregate mass in cis-lunar space to facilitate an expedition from Cis-Lunar Base Camp. Launch vehicles, chemical propulsion stages, and electric propulsion stages are discussed and parametric sizing values are used to create architectures of in-space transportation elements that extend the existing in-space supply chain to cis-lunar space. The transportation options to cis-lunar space assessed vary in efficiency by almost 50%; from 0.16 to 0.68 kg of cargo in cis-lunar space for every kilogram of mass in Low Earth Orbit (LEO). For the 15 cases, 5-year campaign costs vary by only 15% from 0.36 to 0.51 on a normalized scale across all campaigns. Thus the development and first flight costs of assessed transportation options are similar. However, the cost of those options per flight beyond the initial operational capability varies by 70% from 0.3 to 1.0 on a normalized scale. The 10-year campaigns assessed begin to show the effect of this large range of cost beyond initial operational capability as they vary approximately 25% with values from 0.75 to 1.0 on the normalized campaign scale. Therefore, it is important to understand both the cost of implementation and first use as well as long term utilization. Finally, minimizing long term recurring costs is critical to the affordability of future human space exploration missions. Finally minimizing long term recurring costs is critical to the affordability of future human space exploration missions.

  16. Laser treatments of deep-seated brain lesions

    NASA Astrophysics Data System (ADS)

    Ward, Helen A.

    1997-06-01

    The five year survival rate of deep-seated malignant brain tumors after surgery/radiotherapy is virtually 100 percent mortality. Special problems include: (1) Lesions often present late. (2) Position: lesion overlies vital structures, so complete surgical/radiotherapy lesion destruction can damage vital brain-stem functions. (3) Difficulty in differentiating normal brain form malignant lesions. This study aimed to use the unique properties of the laser: (a) to minimize damage during surgical removal of deep-seated brain lesions by operating via fine optic fibers; and (b) to employ the propensity of certain lasers for absorption of dyes and absorption and induction of fluorescence in some brain substances, to differentiate borders of malignant and normal brain, for more complete tumor removal. In the method a fine laser endoscopic technique was devised for removal of brain lesions. The results of this technique, were found to minimize and accurately predict the extent of thermal damage and shock waves to within 1-2mm of the surgical laser beam. Thereby it eliminated the 'popcorn' effect.

  17. Effects of strain on Goos-Hänchen shifts of monolayer phosphorene

    NASA Astrophysics Data System (ADS)

    Li, Kaihui; Cheng, Fang

    2018-03-01

    We investigate the Goos-Hänchen(GH) shift for ballistic electrons (i) reflected from a step-like inhomogeneity of strain, and (ii) transmitted through a monolayer phosphoresce junction consisting of a positive strained region and two normal regions (or a normal region and two negative strained regions). Refraction occurs at the interface between the unstrained/positive-strain(negative-strain/unstrained), in analogy with optical refraction. The critical angle is different for different strengths and directions of the strains. The critical angles for electrons tunneling through unstrained/positive-strain junction can even decrease to zero when the positive strain exceeds a critical value. For the monolayer phosphorene junction consisting of a positive strain region and two normal regions (or a normal region and two negative strain regions), we find that the GH shifts resonantly depends on the middle region width. The resonant values and the plus-minus sign of the displacement can be controlled by the incident angle, incident energy and the strain. These properties will be useful for the applications in phosphorene-based electronic devices.

  18. A kind of improved fingerprinting indoor location method based on WiFi

    NASA Astrophysics Data System (ADS)

    Zeng, Xi; Lin, Wei

    2017-08-01

    In the prior inventions, because of the complexity of the indoor environment, it is hard to guarantee position precision. In this paper provides an improved method that can be adopted to increase the indoor positioning accuracy of handheld positioning device. This method will be the direction of the handheld device position Angle and number of access points two characteristics to join the fingerprint. The two parameters make our normal fingerprint database more abundant. The positioning test results from comparing the normal fingerprint database with the improved fingerprint database prove the later positioning more accurate.

  19. Small Aircraft Transportation System, Higher Volume Operations Concept: Normal Operations

    NASA Technical Reports Server (NTRS)

    Abbott, Terence S.; Jones, Kenneth M.; Consiglio, Maria C.; Williams, Daniel M.; Adams, Catherine A.

    2004-01-01

    This document defines the Small Aircraft Transportation System (SATS), Higher Volume Operations (HVO) concept for normal conditions. In this concept, a block of airspace would be established around designated non-towered, non-radar airports during periods of poor weather. Within this new airspace, pilots would take responsibility for separation assurance between their aircraft and other similarly equipped aircraft. Using onboard equipment and procedures, they would then approach and land at the airport. Departures would be handled in a similar fashion. The details for this operational concept are provided in this document.

  20. Neurological bypass for sensory innervation of the penis in patients with spina bifida.

    PubMed

    Overgoor, Max L E; Kon, Moshe; Cohen-Kettenis, Peggy T; Strijbos, Saskia A M; de Boer, Niels; de Jong, Tom P V M

    2006-09-01

    Most male patients with spina bifida have normal sexual desires. During puberty they begin to realize that they can achieve erection and sexual intercourse but without any sensation in the penis. We hypothesized that restored sensation in the penis would greatly contribute to their quality of life and sexual health. In this prospective study we investigated the outcome of a new operative neurological bypass procedure in patients with spina bifida. In 3 patients who were 17, 18 and 21 years old with a spinal lesion at L5, L4 and L3-L4, respectively, the sensory ilioinguinal nerve (L1) was cut distal in the groin and joined by microneurorrhaphy to the divided ipsilateral dorsal nerve of the penis (S2-4) at the base of the penis. All patients underwent preoperative and postoperative neurological and psychological evaluations. By 15 months postoperatively all patients had achieved excellent sensation on the operated side of the glans penis. They were unequivocally positive about the results and the penis had become more integrated into the body image. In 2 patients masturbation became more meaningful and 1 became more sexually active with and without his partner. The newly designed neurological bypass procedure in patients with spina bifida resulted in excellent sensibility in the glans penis. The new sensation appeared to contribute to the quality of the patient sexuality and sexual functioning as well as to the feeling of being a more normal and complete individual who is more conscious of the penis. This new operation might become standard treatment in patients with spina bifida in the future.

  1. Thermal overload protection for electric motors on safety-related motor-operated valves: Generic Issue II. E. 6. 1

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rothberg, O.

    1988-06-01

    NRC regulatory positions, as stated in Regulatory Guide 1.106, Revision 1, have been identified by the Office for Analysis and Evaluation of Operational Data (AEOD) as potential contributors to valve motor burnout. AEOD is particularly concerned about the allowed policy of bypassing thermal overload devices during normal or accident conditions. Regulatory Guide 1.106 favors compromising the function of thermal overload devices in favor of completing the safety-related action of valves. The purpose of this study was to determine if the guidance contained in Regulatory Guide 1.106 is appropriate and, if not, to recommend the necessary changes. This report describes thermalmore » overload devices commonly used to protect safety-related valve operator motors. The regulatory guidelines stated in Regulatory Guide 1.106 along with the limitations of thermal overload protection are discussed. Supplements and alternatives to thermal overload protection are also described. Findings and conclusions of several AEOD reports are discussed. Information obtained from the standard review plan, standard technical specifications, technical specifications from representative plants, and several papers are cited.« less

  2. Advanced ECCD based NTM control in closed-loop operation at ASDEX Upgrade (AUG)

    NASA Astrophysics Data System (ADS)

    Reich, Matthias; Barrera-Orte, Laura; Behler, Karl; Bock, Alexander; Giannone, Louis; Maraschek, Marc; Poli, Emanuele; Rapson, Chris; Stober, Jörg; Treutterer, Wolfgang

    2012-10-01

    In high performance plasmas, Neoclassical Tearing Modes (NTMs) are regularly observed at reactor-grade beta-values. They limit the achievable normalized beta, which is undesirable because fusion performance scales as beta squared. The method of choice for controlling and avoiding NTMs at AUG is the deposition of ECCD inside the magnetic island for stabilization in real-time (rt). Our approach to tackling such complex control problems using real-time diagnostics allows rigorous optimization of all subsystems. Recent progress in rt-equilibrium reconstruction (< 3.5 ms), rt-localization of NTMs (< 8 ms) and rt beam tracing (< 25 ms) allows closed-loop feedback operation using multiple movable mirrors as the ECCD deposition actuator. The rt-equilibrium uses function parametrization or a fast Grad-Shafranov solver with an option to include rt-MSE measurements. The island localization is based on a correlation of ECE and filtered Mirnov signals. The rt beam-tracing module provides deposition locations and their derivative versus actuator position of multiple gyrotrons. The ``MHD controller'' finally drives the actuators. Results utilizing closed-loop operation with multiple gyrotrons and their effect on NTMs are shown.

  3. Control Code for Bearingless Switched-Reluctance Motor

    NASA Technical Reports Server (NTRS)

    Morrison, Carlos R.

    2007-01-01

    A computer program has been devised for controlling a machine that is an integral combination of magnetic bearings and a switched-reluctance motor. The motor contains an eight-pole stator and a hybrid rotor, which has both (1) a circular lamination stack for levitation and (2) a six-pole lamination stack for rotation. The program computes drive and levitation currents for the stator windings with real-time feedback control. During normal operation, two of the four pairs of opposing stator poles (each pair at right angles to the other pair) levitate the rotor. The remaining two pairs of stator poles exert torque on the six-pole rotor lamination stack to produce rotation. This version is executable in a control-loop time of 40 s on a Pentium (or equivalent) processor that operates at a clock speed of 400 MHz. The program can be expanded, by addition of logic blocks, to enable control of position along additional axes. The code enables adjustment of operational parameters (e.g., motor speed and stiffness, and damping parameters of magnetic bearings) through computer keyboard key presses.

  4. Modeling operators' emergency response time for chemical processing operations.

    PubMed

    Murray, Susan L; Harputlu, Emrah; Mentzer, Ray A; Mannan, M Sam

    2014-01-01

    Operators have a crucial role during emergencies at a variety of facilities such as chemical processing plants. When an abnormality occurs in the production process, the operator often has limited time to either take corrective actions or evacuate before the situation becomes deadly. It is crucial that system designers and safety professionals can estimate the time required for a response before procedures and facilities are designed and operations are initiated. There are existing industrial engineering techniques to establish time standards for tasks performed at a normal working pace. However, it is reasonable to expect the time required to take action in emergency situations will be different than working at a normal production pace. It is possible that in an emergency, operators will act faster compared to a normal pace. It would be useful for system designers to be able to establish a time range for operators' response times for emergency situations. This article develops a modeling approach to estimate the time standard range for operators taking corrective actions or following evacuation procedures in emergency situations. This will aid engineers and managers in establishing time requirements for operators in emergency situations. The methodology used for this study combines a well-established industrial engineering technique for determining time requirements (predetermined time standard system) and adjustment coefficients for emergency situations developed by the authors. Numerous videos of workers performing well-established tasks at a maximum pace were studied. As an example, one of the tasks analyzed was pit crew workers changing tires as quickly as they could during a race. The operations in these videos were decomposed into basic, fundamental motions (such as walking, reaching for a tool, and bending over) by studying the videos frame by frame. A comparison analysis was then performed between the emergency pace and the normal working pace operations to determine performance coefficients. These coefficients represent the decrease in time required for various basic motions in emergency situations and were used to model an emergency response. This approach will make hazardous operations requiring operator response, alarm management, and evacuation processes easier to design and predict. An application of this methodology is included in the article. The time required for an emergency response was roughly a one-third faster than for a normal response time.

  5. Measurements and modeling of long-path 12CH4 spectra in the 4800-5300 cm-1 region

    NASA Astrophysics Data System (ADS)

    Nikitin, A. V.; Thomas, X.; Régalia, L.; Daumont, L.; Rey, M.; Tashkun, S. A.; Tyuterev, Vl. G.; Brown, L. R.

    2014-05-01

    A new study of 12CH4 line positions and intensities was performed for the lower portion of the Tetradecad region between 4800 and 5300 cm-1 using long path (1603 m) spectra of normal sample CH4 at three pressures recorded with the Fourier transform spectrometer in Reims, France. Line positions and intensities were retrieved by least square curve-fitting procedures and analyzed using the effective Hamiltonian and the effective Dipole moment expressed in terms of irreducible tensor operators adapted to spherical top molecules. An existing spectrum of enriched 13CH4 was used to discern the isotopic lines. A new measured linelist produced positions and intensities for 5851 features (a factor of two more than prior work). Assignments were made for 46% of these; 2725 experimental line positions and 1764 selected line intensities were fitted with RMS standard deviations of 0.004 cm-1 and 7.3%, respectively. The RMS of prior intensity fits of the lower Tetradecad was previously a factor of two worse. The sum of observed intensities between 4800 and 5300 cm-1 fell within 5% of the predicted value from variational calculations.

  6. Scenario development for high β p low torque plasma with q min above 2 and large-radius internal transport barrier in DIII-D

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ding, S.; Xu, G. S.; Wang, Q.

    A recent experiment on DIII-D, which was conducted by the joint research team from DIII-D and EAST, has extended the previous high β p, high q min regime, which has been tested in the 2013 DIII-D/EAST joint experiment, to inductive operation at higher plasma current (I p=0.8 MA) and significantly higher normalized fusion performance (G = H 89β N/=qmore » $$2\\atop{95}$$ = 0.16). The experiment aims at exploring high performance scenario with q min > 2 and reduced torque for long pulse operation, which can be potentially extrapolated to EAST. The effort was largely motivated by the interest in developing a feasible scenario for long-pulse high performance operation with low torque on EAST. Very high confinement, H 89 = 3.5 or H 98,y2 = 2.1 with β N ~ 3.0, has been achieved transiently in this experiment together with q min > 2 and reduced NBI torque (3~5 N-m). The excellent confinement is associated with the spontaneous formation of an internal transport barrier (ITB) in plasmas with I p=0.8 MA at large minor radius (normalized p ~ 0.7) in all channels (n e, T e, T i, V Φ, especially strong in the T e channel). Fluctuation measurements show a significant reduction in the fluctuation levels, including AE modes and broadband turbulence, at the location where an ITB forms. Linear gyrokinetic simulations also support the decrease of the growth rate of the most unstable mode during strong ITB formation. The simulation implies that strong suppression of turbulence and a positive feedback loop may be active in this process and is responsible for the spontaneous formation of large-radius ITB. Finally, in an unstable ITB phase, an ELM crash is observed to have a positive effect on transient formation of large-radius ITB. The formation of this kind of ITB is found to have a shielding (protecting) effect on the core plasma while isolating the perturbation due to ELM crash.« less

  7. Scenario development for high β p low torque plasma with q min above 2 and large-radius internal transport barrier in DIII-D

    DOE PAGES

    Ding, S.; Xu, G. S.; Wang, Q.; ...

    2016-09-30

    A recent experiment on DIII-D, which was conducted by the joint research team from DIII-D and EAST, has extended the previous high β p, high q min regime, which has been tested in the 2013 DIII-D/EAST joint experiment, to inductive operation at higher plasma current (I p=0.8 MA) and significantly higher normalized fusion performance (G = H 89β N/=qmore » $$2\\atop{95}$$ = 0.16). The experiment aims at exploring high performance scenario with q min > 2 and reduced torque for long pulse operation, which can be potentially extrapolated to EAST. The effort was largely motivated by the interest in developing a feasible scenario for long-pulse high performance operation with low torque on EAST. Very high confinement, H 89 = 3.5 or H 98,y2 = 2.1 with β N ~ 3.0, has been achieved transiently in this experiment together with q min > 2 and reduced NBI torque (3~5 N-m). The excellent confinement is associated with the spontaneous formation of an internal transport barrier (ITB) in plasmas with I p=0.8 MA at large minor radius (normalized p ~ 0.7) in all channels (n e, T e, T i, V Φ, especially strong in the T e channel). Fluctuation measurements show a significant reduction in the fluctuation levels, including AE modes and broadband turbulence, at the location where an ITB forms. Linear gyrokinetic simulations also support the decrease of the growth rate of the most unstable mode during strong ITB formation. The simulation implies that strong suppression of turbulence and a positive feedback loop may be active in this process and is responsible for the spontaneous formation of large-radius ITB. Finally, in an unstable ITB phase, an ELM crash is observed to have a positive effect on transient formation of large-radius ITB. The formation of this kind of ITB is found to have a shielding (protecting) effect on the core plasma while isolating the perturbation due to ELM crash.« less

  8. [Intraoperative placement of transnasal small intestinal feeding tube during the surgery in 5 cases with high position intestinal obstruction and postoperative feeding].

    PubMed

    Duan, Guang-qi; Zhang, Min; Guan, Xiao-hao; Yin, Zhi-qing

    2012-09-01

    To explore the value of employing the small intestinal feeding tube in treating high position intestinal obstruction of newborn infant. Five newborn infants (3 males and 2 females; 1 premature infant and 4 fully-mature infants; 2 had membranous atresia of duodenum, 1 had annular pancreas, and 2 had proximal small intestine atresia; 1 infant had malrotation). The duodenal membrane-like atresia and the blind-end of small intestine were removed and intestinal anastomosis was performed, which was combined with intestinal malrotation removal. Before the intestinal anastomosis surgery, the anesthetist inserted via nose a 6Fr small intestinal ED tube, made by CREATE MEDIC CO LTD of Japan[ the State Food and Drug Administration-instrument (Im.) 2007-NO.2661620]. Twenty-four hours after surgery, abdominal X-ray plain film was taken and patients were fed with syrup; 48 hours later, formula milk was pumped or lactose-free milk amino acids were given by intravenous injection pump through the feeding tube. The amount of milk and fluids was gradually increased to normal amount according to the condition. In initial 3 days the intravenous nutrition was given and one week after operation, the infants were fed through mouth in addition to pumping milk through the tube and stopped infusion. Ten to 22 days after operation, the tube was removed and the infant patients were discharged. All the five infants showed that the feeding through the nutrition tube was accomplished and the time of venous nutrition was reduced and fistula operation was avoided. None of the infants on question was off the tube and no jaundice exacerbation was found and the liver function was also found normal. At the very beginning, the tube was occasionally blocked by milk vale in one infant and after 0.9% sodium chloride solution flushing patency restored. After that, the feeding tube was washed once with warm water after feeding. In one infant vomiting occurred due to enough oral milk. The photograph of upper gastrointestine did not show anastomomotic stricture or fistula, or intestinal obstruction. After pulling out the tube, the symptoms disappeared and then the patient was discharged. One child was found to have diarrhea with no lactose nutrition liquid and given compound lactic bacteria preparations for oral administration, the symptom disappeared. In the 5 cases, the shortest hospital stay was 10 days and the longest was 22 days, the average stay was 16 days. Three to 5 days after operation the weight restored to birth weight, the weight had increased, when discharged, to an average of 5.5 g (kg·d). The small intestinal feeding tube was very effective for the postoperative nutrition maintenance of high position intestinal obstruction in newborn infants.

  9. Evaluation of Interleukin-17 and Interleukin-23 in Pterygium: Immunohistochemistry Study.

    PubMed

    Tiong, Kiew Ing; Mohd Zahidin, Aida Zairani; Sumugam, S Kala A/P; Uchang, Joseph; Mohd Isa, Hazlita Dato'

    2017-01-01

    To compare the interleukin-17 (IL-17) and interleukin-23 (IL-23) positive cell counts between pterygium and normal conjunctiva. A case-control study. This study received ethical approval (NMRR Research ID 23957) and informed consent was obtained from all participants. It involved 20 participants with 20 samples of pterygium and 20 samples of normal conjunctiva that were obtained from the same eye of each participant. All the participants underwent history taking, slit lamp examination, and pterygium excision surgery. Both samples underwent immunohistochemistry procedure. Pretreatment procedure was conducted using heat-induced epitope retrieval with PT link, subsequently followed by EnVision FLEX staining procedure and incubation with anti‒IL-17 antibody and anti‒IL-23 antibody. Slides were examined in high-power fields (400x) for both samples in 3 different fields. Total positive stained cell counts in all 3 fields with IL-17 and IL-23 between pterygium and normal conjunctiva were analyzed by using Wilcoxon signed rank test. IL-17 positive cell counts for normal conjunctiva showed mean 196.10 ± 80.487 but for pterygium was 331.10 ± 108.416. As for IL-23, the mean for positive cell counts for normal conjunctiva was 62.10 ± 33.462 and IL-23 positive cell counts for pterygium showed mean 102.95 ± 41.378. Both IL-17 and IL-23 were significantly increased in pterygium compared with normal conjunctiva (P < 0.001). Both IL-17 and IL-23 were found to be significantly higher in the pterygium group than in the normal conjunctiva group with P < 0.001 by Wilcoxon signed rank test. Copyright 2017 Asia-Pacific Academy of Ophthalmology.

  10. The National Football League Scouting Combine from 1999 to 2014: normative reference values and an examination of body mass normalization techniques.

    PubMed

    Nuzzo, James L

    2015-02-01

    The primary purpose of this study was to identify the most appropriate method for normalizing physical performance measures to body mass in American football players. Data were obtained from the population of players (n = 4,603) that completed the vertical jump, broad jump, 40-yd sprint, 20-yd shuttle, 3-cone drill, and bench press at the National Football League Scouting Combine from 1999 to 2014. Correlation coefficients were used to assess relationships between body mass and physical performance measures. For the entire group and each playing position, absolute (i.e., non-normalized) performance measures were significantly (p ≤ 0.05) correlated with body mass, indicating that normalization is warranted. Ratio scaling, however, was not appropriate for normalizing most performance measures because it merely reversed (and increased in magnitude) the significant correlations between body mass and performance. Allometric scaling with derived allometric parameters was appropriate for normalizing all performance measures because correlations between body mass and performance were near to zero and no longer statistically significant. However, the derived allometric parameters differed by playing position. Thus, when normalizing physical performance measures to body mass, strength and conditioning professionals should use allometric scaling with test- and position-specific allometric parameters. Additionally, in the current study, percentile rankings were generated to provide test- and position-specific normative reference values for the absolute measures. Until body mass normalization techniques are adopted more broadly, strength and conditioning professionals can use these normative references values to compare current players with those who have already participated in the Scouting Combine.

  11. Culture and error in space: implications from analog environments.

    PubMed

    Helmreich, R L

    2000-09-01

    An ongoing study investigating national, organizational, and professional cultures in aviation and medicine is described. Survey data from 26 nations on 5 continents show highly significant national differences regarding appropriate relationships between leaders and followers, in group vs. individual orientation, and in values regarding adherence to rules and procedures. These findings replicate earlier research on dimensions of national culture. Data collected also isolate significant operational issues in multi-national flight crews. While there are no better or worse cultures, these cultural differences have operational implications for the way crews function in an international space environment. The positive professional cultures of pilots and physicians exhibit a high enjoyment of the job and professional pride. However, a negative component was also identified characterized by a sense of personal invulnerability regarding the effects of stress and fatigue on performance. This misperception of personal invulnerability has operational implications such as failures in teamwork and increased probability of error. A second component of the research examines team error in operational environments. From observational data collected during normal flight operations, new models of threat and error and their management were developed that can be generalized to operations in space and other socio-technological domains. Five categories of crew error are defined and their relationship to training programs in team performance, known generically as Crew Resource Management, is described. The relevance of these data for future spaceflight is discussed.

  12. Physics of collisionless scrape-off-layer plasma during normal and off-normal Tokamak operating conditions.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hassanein, A.; Konkashbaev, I.

    1999-03-15

    The structure of a collisionless scrape-off-layer (SOL) plasma in tokamak reactors is being studied to define the electron distribution function and the corresponding sheath potential between the divertor plate and the edge plasma. The collisionless model is shown to be valid during the thermal phase of a plasma disruption, as well as during the newly desired low-recycling normal phase of operation with low-density, high-temperature, edge plasma conditions. An analytical solution is developed by solving the Fokker-Planck equation for electron distribution and balance in the SOL. The solution is in good agreement with numerical studies using Monte-Carlo methods. The analytical solutionsmore » provide an insight to the role of different physical and geometrical processes in a collisionless SOL during disruptions and during the enhanced phase of normal operation over a wide range of parameters.« less

  13. Understanding nuclear motions in molecules: Derivation of Eckart frame ro-vibrational Hamiltonian operators via a gateway Hamiltonian operator

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Szalay, Viktor, E-mail: szalay.viktor@wigner.mta.hu

    A new ro-vibrational Hamiltonian operator, named gateway Hamiltonian operator, with exact kinetic energy term, T-hat, is presented. It is in the Eckart frame and it is of the same form as Watson’s normal coordinate Hamiltonian. However, the vibrational coordinates employed are not normal coordinates. The new Hamiltonian is shown to provide easy access to Eckart frame ro-vibrational Hamiltonians with exact T-hat given in terms of any desired set of vibrational coordinates. A general expression of the Eckart frame ro-vibrational Hamiltonian operator is given and some of its properties are discussed.

  14. [Estrogen and progesterone receptors in normal cervix and primary cervical carcinoma].

    PubMed

    Shen, K; Yueng, W; Ngan, H

    1994-05-01

    Estrogen and progesterone receptor levels (ER and PR) were measured in 21 specimens of cervical carcinoma and in 17 normal cervix by monoclonal enzyme immunoassay (ER-EIA and PR-EIA). In normal cervix, 88.2% of specimens were ER-positive (more than 15 fmol/mg protein), 74.5% were PR-positive (more than 15 fmol/mg protein) and 74.5% were both ER and PR-positive. In cervical cancer, 66.7% of malignancies were ER-positive, 42.9% were PR-positive and 38.1% were both ER and PR-positive. There was no significant difference in ER status between the normal cervix and cervical cancer (P > 0.05), but PR status and levels in normal cervix were significantly higher than those in cervical carcinoma (P < 0.05). ER levels in squamous cell carcinoma was not correlated to the tumor stage, histologic grade and menopausal status. PR levels in premenopausal patients with squamous cell carcinoma were significantly higher than those in postmenopausal patients (P < 0.01). Adenocarcinoma of the cervix contained significantly more ER and PR than squamous cell carcinoma (P < 0.01, P < 0.05). In addition, serum E2 level was also assayed in 21 patients with cervical cancer. There was significant difference in E2 levels between the premenopausal and postmenopausal patients (P < 0.01). Patients were stratified according to E2 levels, a significant difference in PR level and in ratio of PR/ER was noted (P < 0.05, P < 0.01).

  15. Systematic changes in position sense accompany normal aging across adulthood.

    PubMed

    Herter, Troy M; Scott, Stephen H; Dukelow, Sean P

    2014-03-25

    Development of clinical neurological assessments aimed at separating normal from abnormal capabilities requires a comprehensive understanding of how basic neurological functions change (or do not change) with increasing age across adulthood. In the case of proprioception, the research literature has failed to conclusively determine whether or not position sense in the upper limb deteriorates in elderly individuals. The present study was conducted a) to quantify whether upper limb position sense deteriorates with increasing age, and b) to generate a set of normative data that can be used for future comparisons with clinical populations. We examined position sense in 209 healthy males and females between the ages of 18 and 90 using a robotic arm position-matching task that is both objective and reliable. In this task, the robot moved an arm to one of nine positions and subjects attempted to mirror-match that position with the opposite limb. Measures of position sense were recorded by the robotic apparatus in hand-and joint-based coordinates, and linear regressions were used to quantify age-related changes and percentile boundaries of normal behaviour. For clinical comparisons, we also examined influences of sex (male versus female) and test-hand (dominant versus non-dominant) on all measures of position sense. Analyses of hand-based parameters identified several measures of position sense (Variability, Shift, Spatial Contraction, Absolute Error) with significant effects of age, sex, and test-hand. Joint-based parameters at the shoulder (Absolute Error) and elbow (Variability, Shift, Absolute Error) also exhibited significant effects of age and test-hand. The present study provides strong evidence that several measures of upper extremity position sense exhibit declines with age. Furthermore, this data provides a basis for quantifying when changes in position sense are related to normal aging or alternatively, pathology.

  16. Assessment of the Melody Valve in the Mitral Position in Young Children by Echocardiography

    PubMed Central

    Freud, Lindsay R.; Marx, Gerald R.; Marshall, Audrey C.; Tworetzky, Wayne; Emani, Sitaram M.

    2018-01-01

    Objectives Mitral valve replacement (MVR) in young children is limited by lack of small prostheses. Our institution began performing MVR with modified, surgically placed, stented jugular vein grafts (Melody valve) in 2010. We sought to describe key echocardiographic features for pre- and post-operative assessment of this novel form of MVR. Methods The pre- and post-operative echocardiograms of 24 patients who underwent Melody MVR were reviewed. In addition to standard measurements, pre-operative potential measurements of the mitral annulus were performed whereby dimensions were estimated for Melody sizing. A ratio of the narrowest subaortic region in systole to the actual mitral valve dimension (SubA:MV) was assessed for risk of post-operative left ventricular outflow tract obstruction (LVOTO). Results Melody MVR was performed at a median of 8.5 months (5.6 kg) for stenosis (5), regurgitation (3), and mixed disease (16). Pre-operatively, actual mitral z-scores measured hypoplastic (median −3.1 for the lateral (lat) dimension; −2.1 for the antero-posterior (AP) dimension). The potential measurements often had normal z-scores with fair correlation with intra-operative Melody dilation (ρ=0.51 and 0.50 for lat and AP dimensions, both p=0.01). A pre-operative SubA:MV <0.5 was associated with post-operative LVOTO, which occurred in four patients. Post-operatively, mitral gradients substantially improved, with low values relative to the effective orifice area of the Melody valve. No patients had significant regurgitation or perivalvar leak. Conclusions Pre-operative echocardiographic measurements may help guide intra-operative sizing for Melody MVR and identify patients at risk for post-operative LVOTO. Acute post-operative hemodynamic results were favorable; however, on-going assessment is warranted. PMID:27523403

  17. 10 CFR 50.60 - Acceptance criteria for fracture prevention measures for lightwater nuclear power reactors for...

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... lightwater nuclear power reactors for normal operation. 50.60 Section 50.60 Energy NUCLEAR REGULATORY... lightwater nuclear power reactors for normal operation. (a) Except as provided in paragraph (b) of this section, all light-water nuclear power reactors, other than reactor facilities for which the...

  18. 10 CFR 50.60 - Acceptance criteria for fracture prevention measures for lightwater nuclear power reactors for...

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... lightwater nuclear power reactors for normal operation. 50.60 Section 50.60 Energy NUCLEAR REGULATORY... lightwater nuclear power reactors for normal operation. (a) Except as provided in paragraph (b) of this section, all light-water nuclear power reactors, other than reactor facilities for which the...

  19. 75 FR 69502 - Self-Regulatory Organizations; The NASDAQ Stock Market LLC; Notice of Filing and Immediate...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-11-12

    ... Connection testing [using current Nasdaq access protocols] during the normal operating hours of the NTF; No Charge--For Idle Connection testing [using current Nasdaq access protocols]; $333/hour--For Active Connection testing [using current Nasdaq access protocols] at all times other than the normal operating hours...

  20. 7 CFR 701.23 - Eligible costs.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ....27. (b) Eligible costs shall be limited as follows: (1) Costs for use of personal equipment shall be limited to those incurred beyond the normal operation of the farm or ranch. (2) Costs for personal labor shall be limited to personal labor not normally required in the operation of the farm or ranch. (3...

  1. Versatile solid-state relay

    NASA Technical Reports Server (NTRS)

    Fox, D. A.

    1977-01-01

    Solid-state relay (SSR), containing multinode control logic, is operated as normally open, normally closed, or latched. Moreover several can be paralleled to form two-pole or double-throw relays. Versatile unit ends need to design custom control circuit for every relay application. Technique can be extended to incorporate selectable time delay, on operation or release, or pulsed output.

  2. 14 CFR 27.1316 - Electrical and electronic system lightning protection.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... after the time the rotorcraft is exposed to lightning; and (2) The system automatically recovers normal operation of that function in a timely manner after the rotorcraft is exposed to lightning. (b) For... recovers normal operation in a timely manner after the rotorcraft is exposed to lightning. [Doc. No. FAA...

  3. 14 CFR 27.1316 - Electrical and electronic system lightning protection.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... after the time the rotorcraft is exposed to lightning; and (2) The system automatically recovers normal operation of that function in a timely manner after the rotorcraft is exposed to lightning. (b) For... recovers normal operation in a timely manner after the rotorcraft is exposed to lightning. [Doc. No. FAA...

  4. 14 CFR 27.1316 - Electrical and electronic system lightning protection.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... after the time the rotorcraft is exposed to lightning; and (2) The system automatically recovers normal operation of that function in a timely manner after the rotorcraft is exposed to lightning. (b) For... recovers normal operation in a timely manner after the rotorcraft is exposed to lightning. [Doc. No. FAA...

  5. 45 CFR 90.13 - Definitions of normal operation and statutory objective.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... objective. 90.13 Section 90.13 Public Welfare DEPARTMENT OF HEALTH AND HUMAN SERVICES GENERAL ADMINISTRATION... statutory objective. For purposes of §§ 90.14, and 90.15, the terms normal operation and statutory objective... without significant changes that would impair its ability to meet its objectives. (b) Statutory objective...

  6. LiDAR Scan Matching Aided Inertial Navigation System in GNSS-Denied Environments

    PubMed Central

    Tang, Jian; Chen, Yuwei; Niu, Xiaoji; Wang, Li; Chen, Liang; Liu, Jingbin; Shi, Chuang; Hyyppä, Juha

    2015-01-01

    A new scan that matches an aided Inertial Navigation System (INS) with a low-cost LiDAR is proposed as an alternative to GNSS-based navigation systems in GNSS-degraded or -denied environments such as indoor areas, dense forests, or urban canyons. In these areas, INS-based Dead Reckoning (DR) and Simultaneous Localization and Mapping (SLAM) technologies are normally used to estimate positions as separate tools. However, there are critical implementation problems with each standalone system. The drift errors of velocity, position, and heading angles in an INS will accumulate over time, and on-line calibration is a must for sustaining positioning accuracy. SLAM performance is poor in featureless environments where the matching errors can significantly increase. Each standalone positioning method cannot offer a sustainable navigation solution with acceptable accuracy. This paper integrates two complementary technologies—INS and LiDAR SLAM—into one navigation frame with a loosely coupled Extended Kalman Filter (EKF) to use the advantages and overcome the drawbacks of each system to establish a stable long-term navigation process. Static and dynamic field tests were carried out with a self-developed Unmanned Ground Vehicle (UGV) platform—NAVIS. The results prove that the proposed approach can provide positioning accuracy at the centimetre level for long-term operations, even in a featureless indoor environment. PMID:26184206

  7. LiDAR Scan Matching Aided Inertial Navigation System in GNSS-Denied Environments.

    PubMed

    Tang, Jian; Chen, Yuwei; Niu, Xiaoji; Wang, Li; Chen, Liang; Liu, Jingbin; Shi, Chuang; Hyyppä, Juha

    2015-07-10

    A new scan that matches an aided Inertial Navigation System (INS) with a low-cost LiDAR is proposed as an alternative to GNSS-based navigation systems in GNSS-degraded or -denied environments such as indoor areas, dense forests, or urban canyons. In these areas, INS-based Dead Reckoning (DR) and Simultaneous Localization and Mapping (SLAM) technologies are normally used to estimate positions as separate tools. However, there are critical implementation problems with each standalone system. The drift errors of velocity, position, and heading angles in an INS will accumulate over time, and on-line calibration is a must for sustaining positioning accuracy. SLAM performance is poor in featureless environments where the matching errors can significantly increase. Each standalone positioning method cannot offer a sustainable navigation solution with acceptable accuracy. This paper integrates two complementary technologies-INS and LiDAR SLAM-into one navigation frame with a loosely coupled Extended Kalman Filter (EKF) to use the advantages and overcome the drawbacks of each system to establish a stable long-term navigation process. Static and dynamic field tests were carried out with a self-developed Unmanned Ground Vehicle (UGV) platform-NAVIS. The results prove that the proposed approach can provide positioning accuracy at the centimetre level for long-term operations, even in a featureless indoor environment.

  8. Legionnaires' disease bacteria in power plant cooling systems: downtime report. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tyndall, R.L.; Solomon, J.A.; Christensen, S.W.

    1985-11-01

    Legionnaires' disease bacteria (Legionella) are a normal part of the aquatic community that, when aerosolized, can be pathogenic to man. The downtime study was designed to determine the degree to which Legionella populations are aerosolized during cleaning and maintenance operations in a closed-cycle steam-electric power plant. Both high-volume and impinger air samples were collected prior to and during downtime operations. Emphasis was placed on sampling inside or adjacent to water boxes, condensers, and cooling towers. Control air samples were taken upwind from the plant site. Water and sludge samples were also collected at various locations. In the laboratory, the concentrationsmore » of Legionella were determined using the direct fluorescent antibody method. All positive air samples, and other selected air samples, were injected into guinea pigs to detect infectious Legionella. Legionella could be detected in only 12 of the 127 air samples collected. These were predominantly L. pneumophila, serogroups 1-6. In contrast to the air samples, most of the water and sludge samples were positive for Legionella, again predominantly L. pneumophila, serogroups 1-6. The highest Legionella concentrations were found in sludge samples associated with condenser tube cleaning. Among the water samples, the highest Legionella concentrations were found in cooling towers, immediately after the tower basins were cleaned and refilled, and in condenser tubes. Two of the three cooling tower water samples collected prior to downtime operations were infectious for guinea pigs. 16 refs., 4 figs., 11 tabs.« less

  9. Uterine fibroids with positive 18F-FDG PET/CT image and significantly increased CA19-9: A case report.

    PubMed

    Ma, Yan; Shao, Xiaonan

    2017-12-01

    Uterine fibroids are the most common pelvic solid tumors and common to 25% of women. F-fluorodexyglucose (F-FDG) is an energy metabolism tracer. Although FDG is generally concentrated in malignant lesions with high glucose metabolism, it can also accumulate in normal tissues, benign lesions, and inflammatory sites. The exact mechanism of FDG uptake by uterine fibroids is not clear. Here, we report a case of uterine fibroids with positive F-FDG positron emission tomography/computed tomography (PET/CT) imaging and significantly increased CA19-9. The patient was a 43-year-old woman and admitted to our hospital because of "1-year-extended menstrual periods." At admission, she had normal CA125, AFP, and CEA level and CA19-9>1000.00 U/mL. Gynecological transvaginal ultrasound found enlarged uterus with an anterior hypoechoic area of 3.9 × 4.2 cm. CT and contrast-enhanced CT showed significantly enhanced mass shadow on the left anterior wall of uterus. F-FDG PET/CT showed increased FDG metabolism of tumor in the anterior wall of the uterus. Laparoscopic hysterectomy was performed. Pathological examination demonstrated subserosal leiomyoma. Her CA19-9 level dropped to 91.50 U/mL 1 day after surgery. Significantly elevated CA19-9 was positioned in the uterus by PET/CT imaging, which not only avoided unnecessary gastrointestinal endoscopy and reduced the suffering of patients, but also strengthened the operation confidence in gynecologists. Copyright © 2017 The Authors. Published by Wolters Kluwer Health, Inc. All rights reserved.

  10. [Influence of shenxu gutong capsule on femoral inorganic elements content and ash weight in rats].

    PubMed

    Chen, X; Wei, J; Chen, Y

    1998-02-01

    To explore the mechanism of Shenxu Gutong Capsule (SXGTC) in treating postmenopausal osteoporosis. Using ovariectomized rats as the model of postmenopausal osteoporosis, the effect of SXGTC on inorganic element content of femur and femoral ash weight of the model rats were surveyed. Animals were divided into model group, SXGTC high dose group, SXGTC low dose group, positive control group (treated with Gushukang) and normal control group. The medication began at one week after operation and lasting for 120 days. The contents of inorganic elements, including Ca, P, Mg, Zn, Cu and Mn in the three medicated groups were higher than those of the model group (P < 0.01). The effect of SXGTC was dose dependent. The difference between the SXGTC groups and the positive control group was insignificant. The femoral ash weight of the SXGTC high dose group and the positive control group was significantly higher than that of the model group (P < 0.01). SXGTC could antagonize the rat's bony change caused by ovariectomy to increase the inorganic contents in bone, which may, in grneral, lead to a bone-strengthening effect.

  11. [Robotic prostatectomy: The anesthetist's view for robotic urological surgeries, a prospective study].

    PubMed

    Oksar, Menekse; Akbulut, Ziya; Ocal, Hakan; Balbay, Mevlana Derya; Kanbak, Orhan

    2014-01-01

    Although many features of robotic prostatectomy are similar to those of conventional laparoscopic urological procedures (such as laparoscopic prostatectomy), the procedure is associated with some drawbacks, which include limited intravenous access, relatively long operating time, deep Trendelenburg position, and high intra-abdominal pressure. The primary aim was to describe respiratory and hemodynamic challenges and the complications related to high intra-abdominal pressure and the deep Trendelenburg position in robotic prostatectomy patients. The secondary aim was to reveal safe discharge criteria from the operating room. Fifty-three patients who underwent robotic prostatectomy between December 2009 and January 2011 were prospectively enrolled. Main outcome measures were non-invasive monitoring, invasive monitoring and blood gas analysis performed at supine (T0), Trendelenburg (T1), Trendelenburg + pneumoperitoneum (T2), Trendelenburg-before desufflation (T3), Trendelenburg (after desufflation) (T4), and supine (T5) positions. Fifty-three robotic prostatectomy patients were included in the study. The main clinical challenge in our study group was the choice of ventilation strategy to manage respiratory acidosis, which is detected through end-tidal carbon dioxide pressure and blood gas analysis. Furthermore, the mean arterial pressure remained unchanged, the heart rate decreased significantly and required intervention. The central venous pressure values were also above the normal limits. Respiratory acidosis and "upper airway obstruction-like" clinical symptoms were the main challenges associated with robotic prostatectomy procedures during this study. Copyright © 2013 Sociedade Brasileira de Anestesiologia. Publicado por Elsevier Editora Ltda. All rights reserved.

  12. The insertional torque of a pedicle screw has a positive correlation with bone mineral density in posterior lumbar pedicle screw fixation.

    PubMed

    Lee, J H; Lee, J-H; Park, J W; Shin, Y H

    2012-01-01

    In patients with osteoporosis there is always a strong possibility that pedicle screws will loosen. This makes it difficult to select the appropriate osteoporotic patient for a spinal fusion. The purpose of this study was to determine the correlation between bone mineral density (BMD) and the magnitude of torque required to insert a pedicle screw. To accomplish this, 181 patients with degenerative disease of the lumbar spine were studied prospectively. Each underwent dual-energy x-ray absorptiometry (DEXA) and intra-operative measurement of the torque required to insert each pedicle screw. The levels of torque generated in patients with osteoporosis and osteopenia were significantly lower than those achieved in normal patients. Positive correlations were observed between BMD and T-value at the instrumented lumbar vertebrae, mean BMD and mean T-value of the lumbar vertebrae, and mean BMD and mean T-value of the proximal femur. The predictive torque (Nm) generated during pedicle screw insertion was [-0.127 + 1.62 × (BMD at the corresponding lumbar vertebrae)], as measured by linear regression analysis. The positive correlation between BMD and the maximum torque required to insert a pedicle screw suggests that pre-operative assessment of BMD may be useful in determining the ultimate strength of fixation of a device, as well as the number of levels that need to be fixed with pedicle screws in patients who are suspected of having osteoporosis.

  13. Human papillomavirus in normal conjunctival tissue and in conjunctival papilloma: types and frequencies in a large series

    PubMed Central

    Sjö, Nicolai Christian; von Buchwald, Christian; Cassonnet, Patricia; Norrild, Bodil; Prause, Jan Ulrik; Vinding, Troels; Heegaard, Steffen

    2007-01-01

    Aim To examine conjunctival papilloma and normal conjunctival tissue for the presence of human papillomavirus (HPV). Methods Archival paraffin wax‐embedded tissue from 165 conjunctival papillomas and from 20 histological normal conjunctival biopsy specimens was analysed for the presence of HPV by PCR. Specimens considered HPV positive using consensus primers, but with a negative or uncertain PCR result using type‐specific HPV probes, were analysed with DNA sequencing. Results HPV was present in 86 of 106 (81%) β‐globin‐positive papillomas. HPV type 6 was positive in 80 cases, HPV type 11 was identified in 5 cases and HPV type 45 was present in a single papilloma. All the 20 normal conjunctival biopsy specimens were β‐globin positive and HPV negative. Conclusion There is a strong association between HPV and conjunctival papilloma. The study presents the largest material of conjunctival papilloma investigated for HPV and the first investigation of HPV in normal conjunctival tissue. HPV types 6 and 11 are the most common HPV types in conjunctival papilloma. This also is the first report of HPV type 45 in conjunctival papilloma. PMID:17166894

  14. Operator Variability in Scan Positioning is a Major Component of HR-pQCT Precision Error and is Reduced by Standardized Training

    PubMed Central

    Bonaretti, Serena; Vilayphiou, Nicolas; Chan, Caroline Mai; Yu, Andrew; Nishiyama, Kyle; Liu, Danmei; Boutroy, Stephanie; Ghasem-Zadeh, Ali; Boyd, Steven K.; Chapurlat, Roland; McKay, Heather; Shane, Elizabeth; Bouxsein, Mary L.; Black, Dennis M.; Majumdar, Sharmila; Orwoll, Eric S.; Lang, Thomas F.; Khosla, Sundeep; Burghardt, Andrew J.

    2017-01-01

    Introduction HR-pQCT is increasingly used to assess bone quality, fracture risk and anti-fracture interventions. The contribution of the operator has not been adequately accounted in measurement precision. Operators acquire a 2D projection (“scout view image”) and define the region to be scanned by positioning a “reference line” on a standard anatomical landmark. In this study, we (i) evaluated the contribution of positioning variability to in vivo measurement precision, (ii) measured intra- and inter-operator positioning variability, and (iii) tested if custom training software led to superior reproducibility in new operators compared to experienced operators. Methods To evaluate the operator in vivo measurement precision we compared precision errors calculated in 64 co-registered and non-co-registered scan-rescan images. To quantify operator variability, we developed software that simulates the positioning process of the scanner’s software. Eight experienced operators positioned reference lines on scout view images designed to test intra- and inter-operator reproducibility. Finally, we developed modules for training and evaluation of reference line positioning. We enrolled 6 new operators to participate in a common training, followed by the same reproducibility experiments performed by the experienced group. Results In vivo precision errors were up to three-fold greater (Tt.BMD and Ct.Th) when variability in scan positioning was included. Inter-operator precision errors were significantly greater than short-term intra-operator precision (p<0.001). New trained operators achieved comparable intra-operator reproducibility to experienced operators, and lower inter-operator reproducibility (p<0.001). Precision errors were significantly greater for the radius than for the tibia. Conclusion Operator reference line positioning contributes significantly to in vivo measurement precision and is significantly greater for multi-operator datasets. Inter-operator variability can be significantly reduced using a systematic training platform, now available online (http://webapps.radiology.ucsf.edu/refline/). PMID:27475931

  15. CONNECTOR

    DOEpatents

    Stevens, D.J.

    1962-01-23

    A multiple-contact electrical connector is designed for facilitating correct alignment of the contacts of a movable component with the contacts in a normally stationary component. The stationary connector component, which is normally positioned in a panel, is provided with a fiangemount which permits rotary adjustment of the normally stationary connector component to a desired aligned position with respeet to contacts in the other connector component. The fiange-mount which comprises a fiange on the connector component and a clamping ring may then be secured to the panel by drawing the clamping ring tightly against the flange, thus binding the latter between the ring and the panel for securing the eomponent in desired fixed position. (AEC)

  16. Effects of microRNA-223 on morphine analgesic tolerance by targeting NLRP3 in a rat model of neuropathic pain

    PubMed Central

    Xie, Xiao-Juan; Ma, Li-Gang; Xi, Kai; Fan, Dong-Mei; Li, Jian-Guo; Zhang, Quan; Zhang, Wei

    2017-01-01

    Objective To investigate the effects of microRNA-223 on morphine analgesic tolerance by targeting NLRP3 in a rat model of neuropathic pain. Methods Our study selected 100 clean grade healthy Sprague-Dawley adult male rats weighing 200 to 250 g. After establishment of a rat model of chronic constriction injury, these rats were divided into 10 groups (10 rats in each group): the normal control, sham operation, chronic constriction injury, normal saline, morphine, miR-223, NLRP3, miR-223 + morphine, NLRP3 + morphine, and miR-223 + NLRP3 + morphine groups. The real-time quantitative polymerase chain reaction assay, Western blotting, and enzyme-linked immunosorbent assay were used for detecting the mRNA and protein expressions of NLRP3, apoptosis-associated speck-like protein, Caspase-1, Interleukin (IL)-1β, and IL-18 in sections of lumbar spinal cord. Immunohistochemistry was applied for detecting the positive rates of NLRP3, apoptosis-associated speck-like protein, Caspase-1, IL-1β, and IL-18. Results The paw withdrawal threshold and percentage maximum possible effect (%MPE) were higher in chronic constriction injury group when compared with the normal control and sham operation groups. Behavioral tests showed that compared with the chronic constriction injury and normal saline groups, the morphine and miR-223 + morphine groups showed obvious analgesic effects. Expressions of miR-223 in the miR-223, miR-223 + morphine, and miR-223 + NLRP3 + morphine were significantly higher than those in the chronic constriction injury, normal saline, and morphine groups. Compared with chronic constriction injury, normal saline and morphine groups, the mRNA and protein expressions of NLRP3, apoptosis-associated speck-like protein, Caspase-1, IL-1β, and IL-18 were significantly decreased in the miR-223 and miR-223 + morphine groups, while mRNA and protein expressions of NLRP3, apoptosis-associated speck-like protein, Caspase-1, IL-1β, and IL-18 were significantly increased in the NLRP3 and NLRP3 + morphine group. Conclusion Our study provides strong evidence that miR-223 could suppress the activities of NLRP3 inflammasomes (NLRP3, apoptosis-associated speck-like protein, and Caspase-1) to relieve morphine analgesic tolerance in rats by down-regulating NLRP3. PMID:28580822

  17. Localized chromophobe renal cell carcinoma: preoperative imaging judgment and laparoscopic simple enucleation for treatment.

    PubMed

    Ren, Wenbiao; Xue, Bichen; Qu, Jiandong; Liu, Longfei; Li, Chao; Zu, Xiongbing

    2018-04-30

    To evaluate the preoperative imaging manifestation and therapeutic effect of laparoscopic simple enucleation (SE) for localized chromophobe renal cell carcinoma (chRCC). Clinical data of 36 patients who underwent laparoscopic SE of localized chRCC at our institute were retrospectively analyzed. All patients underwent preoperative renal protocol CT (unenhanced, arterial, venous, and delayed images). CT scan characteristics were evaluated. After intraoperative occlusion of the renal artery, the tumor was free bluntly along the pseudocapsule and enucleated totally. The patients were followed up regularly after the operation. Mean tumor diameter was 3.9±1.0 cm, 80% of tumors were homogeneous and all the tumors had complete pseudocapsule. The attenuation values were slightly lower than normal renal cortex and degree of enhancement of the tumors were significantly lower than normal renal cortex. Mean operation time was 104.3±18.2 min. Mean warm ischemia time (WIT) was 21.3±3.5 min. Mean blood loss was 78.6±25.4 mL. No positive surgical margin was identified. Mean postoperative hospital stay was 5.3±1.5 d. Hematuria occurred in 3 patients and all disappeared within 3 days. After a mean follow-up of 32.1±20.6 months, no patient had local recurrence or metastatic progression. Localized chRCCs have a great propensity for homogeneity and complete pseudocapsule. The attenuation values were slightly lower than normal renal cortex and small degree of enhancement. Laparoscopic SE is a safe and effective treatment for localized chRCC. The oncological results were satisfactory. Copyright® by the International Brazilian Journal of Urology.

  18. Totally tubeless percutaneous nephrolithotomy is feasible in morbidly obese patients.

    PubMed

    Aghamir, Seyed Mohammad Kazem; Mohseni, Mohammad Ghasem; Hosseini, Seyed Reza; Salavati, Alborz; Ganjali, Hossein; Fallah, Mohammad Ali; Rezaei, Hamed; Modaresi, Seyed Saeed

    2017-06-01

    Regarding technical difficulties that obese body habitus might impose to percutaneous nephrolithotomy (PNL) success and higher risk of peri-operative complications in this group of patients, we decided to retrospectively gather data from our patients during past 8 years to determine the stone free and complication rates. Between January 2007-December 2015, seventy-eight obese patients with body mass index over 35 who had indication for PNL including stones larger than 2 cm in pelvi-calyceal system or smaller extracorporeal shock wave lithotripsy (ESWL) resistant stones or who were not a fit candidate for ESWL due to increased skin to target distance, with no contraindication of PNL (including bleeding diathesis, inability to be positioned in prone) were enrolled. They were randomly assigned to group 1 (standard PNL with nephrostomy and ureteral stent) or group 2 (totally tubeless PNL with no ureteral stent and no nephrostomy). The outcomes were compared. The transfusion rate, operation time, and the hemoglobin drop were same across the groups (p>0.05). Total analgesic use was equivalent of 33.8 vs. 14.7 mgs of morphine sulfate (18-77 mg) and was significantly lower in total tubeless group (p=0.001). Return to normal activity was described as total number of in-patient and outpatient days from time of admission to the point which the patients returns to normal life activity such as going to job or school and was 19.4 vs. 9.3 days (6-30 days, p=0.001). Totally tubeless PNL in obese subjects would have lower analgesic use and return to normal activity versus standard PNL. Totally tubeless PNL is recommended for obese patients.

  19. Relationship between hamstring length and gluteus maximus strength with and without normalization.

    PubMed

    Lee, Dong-Kyu; Oh, Jae-Seop

    2018-01-01

    [Purpose] This study assessed the relationship between hamstring length and gluteus maximus (GM) strength with and without normalization by body weight and height. [Subjects and Methods] In total, 34 healthy male subjects volunteered for this study. To measure GM strength, subjects performed maximal hip joint extension with the knee joints flexed to 90° in the prone position. GM strength was normalized for body weight and height. [Results] GM strength with normalization was positively correlated with hamstring length, whereas GM strength without normalization was negatively correlated with hamstring length. [Conclusion] The normalization of GM strength by body weight and height has the potential to lead to more appropriate conclusions and interpretations about its correlation with hamstring length. Hamstring length may be related to GM strength.

  20. Amplitude/frequency differences in a supine resting single-lead electrocardiogram of normal versus coronary heart diseased males.

    DOT National Transportation Integrated Search

    1974-05-01

    A resting 'normal' ECG can coexist with known angina pectoris, positive angiocardiography and previous myocardial infarction. In contemporary exercise ECG tests, a false positive/false negative total error of 10% is not unusual. Research aimed at imp...

  1. A female patient with congenital pouch colon (CPC): a case report.

    PubMed

    Yilmaz, O; Genc, A; Ayhan, S; Ozcan, T; Aygoren, R; Taneli, C

    2011-01-01

    Congenital short colon, more commonly known as pouch colon, is a rare anomaly that can be encountered with anorectal malformations (ARM). The colon is shorter than normal and the distal end is dilated like a pouch. We report the case of a newborn with a Type 2 pouch colon. A female newborn was brought to our clinic with a diagnosis of cloaca anomaly. Her physical examination revealed a single canal introitus and flat perineum. In the abdominal x-ray taken in the upright position, a prominent air sac was noticed at the left side. A laparotomy was performed and exploration demonstrated that the colon was like a pouch. The pouch terminated in the upper part of the vagina with a wide canal. A genitogram displayed the presence of double uteri and double vaginas. One month after the operation we performed a cystoscopy, which showed the urethral meatus to be more proximal than normal (female type hypospadias). When the patient was 8 months old she was re-operated and anterior-abdomino-posterior sagittal anorectoplasty plus tube coloplasty were performed. She is now 4 years old and has a stool discharge of 2-3 times a day. Her physical and psychosocial development is in concordance with her age. Congenital pouch colon is a very rare anomaly, which has to be considered especially during the clinical evaluation of children with cloacal malformations and high type anorectal anomalies.

  2. Human cytokine responses induced by Gram-positive cell walls of normal intestinal microbiota

    PubMed Central

    Chen, T; Isomäki, P; Rimpiläinen, M; Toivanen, P

    1999-01-01

    The normal microbiota plays an important role in the health of the host, but little is known of how the human immune system recognizes and responds to Gram-positive indigenous bacteria. We have investigated cytokine responses of peripheral blood mononuclear cells (PBMC) to Gram-positive cell walls (CW) derived from four common intestinal indigenous bacteria, Eubacterium aerofaciens (Eu.a.), Eubacterium limosum(Eu.l.), Lactobacillus casei(L.c.), and Lactobacillus fermentum (L.f.). Our results indicate that Gram-positive CW of the normal intestinal microbiota can induce cytokine responses of the human PBMC. The profile, level and kinetics of these responses are similar to those induced by lipopolysaccharide (LPS) or CW derived from a pathogen, Streptococcus pyogenes (S.p.). Bacterial CW are capable of inducing production of a proinflammatory cytokine, tumour necrosis factor-alpha (TNF-α), and an anti-inflammatory cytokine, IL-10, but not that of IL-4 or interferon-gamma (IFN-γ). Monocytes are the main cell population in PBMC to produce TNF-α and IL-10. Induction of cytokine secretion is serum-dependent; both CD14-dependent and -independent pathways are involved. These findings suggest that the human cytokine responses induced by Gram-positive CW of the normal intestinal microbiota are similar to those induced by LPS or Gram-positive CW of the pathogens. PMID:10540188

  3. A single sample study of dissociation between expressed and experienced pleasure by gender in mild depression.

    PubMed

    Brown, S L

    Thirty male and thirty female adult subjects were divided equally into three groups on the basis of the Zung Self-Rating Depression Scale; mildly depressed (50-63), normal (40-49), and "low normal" (20-39). Observer ratings of positive affect were made during a one and one-half hour laboratory experiment, and self-ratings of pleasurable experience were collected at the end of the experiment. Results showed no significant differences between groups for self-report of experienced pleasure. However, a significant difference between groups was found for observer ratings of positive affect, with the mildly depressed and "low normal" subjects showing a shorter duration and a lower degree of positive affect than the normals. These results partially replicate and extended previous work. Implications for theory, research, and psychotherapy are discussed.

  4. HPV DNA testing in population-based cervical screening (VUSA-Screen study): results and implications

    PubMed Central

    Rijkaart, D C; Berkhof, J; van Kemenade, F J; Coupe, V M H; Rozendaal, L; Heideman, D A M; Verheijen, R H M; Bulk, S; Verweij, W; Snijders, P J F; Meijer, C J L M

    2012-01-01

    Background: Human papillomavirus (HPV) testing is more sensitive than cytology for detecting high-grade cervical intraepithelial neoplasia (CIN). We evaluated the performance of high-risk HPV (hrHPV) testing in routine screening. Methods: In all, 25 871 women (29–61) enrolled in our population-based cohort study were offered both cytology and hrHPV testing. High-risk HPV-positive women with normal cytology and an age-matched subcohort of hrHPV-negative women with normal cytology were invited for repeat testing after 1 and/or 2 years and were referred for colposcopy if they presented with abnormal cytology and/or a positive hrHPV test. The hrHPV-positive women with borderline or mild dyskaryosis (BMD) and all women with moderate dyskaryosis or worse (>BMD) were directly referred for colposcopy. Women with BMD and an hrHPV-negative test were advised to repeat cytology at 6 and 18 months and were referred for colposcopy if the repeat cytology test was abnormal. The main outcome measure was CIN grade 3 or worse (CIN3+). Results were adjusted for non-attendance at repeat testing. Results: The hrHPV-positive women with abnormal cytology had a CIN3+ risk of 42.2% (95% confidence interval (CI): 36.4–48.2), whereas the hrHPV-positive women with normal cytology had a much lower risk of 5.22% (95% CI: 3.72–7.91). In hrHPV-positive women with normal cytology, an additional cytology step after 1 year reduced the CIN3+ risk to only 1.6% (95% CI: 0.6–4.9) if the repeat test was normal. The CIN3+ risk in women with hrHPV-positive normal cytology was higher among women invited for the first time (29–33 years of age) (9.1% 95% CI: 5.6–14.3) than among older women (3.0% 95% CI: 1.5–5.5). Conclusion: Primary hrHPV screening with cytology triage in women aged ⩾30 years is an effective way to stratify women on CIN3+ risk and seems a feasible alternative to cytological screening. Repeat cytology after 1 year for hrHPV-positive women with normal cytology is however necessary before returning women to routine screening. PMID:22251922

  5. An Order Insertion Scheduling Model of Logistics Service Supply Chain Considering Capacity and Time Factors

    PubMed Central

    Yang, Yi; Wang, Shuqing; Liu, Yang

    2014-01-01

    Order insertion often occurs in the scheduling process of logistics service supply chain (LSSC), which disturbs normal time scheduling especially in the environment of mass customization logistics service. This study analyses order similarity coefficient and order insertion operation process and then establishes an order insertion scheduling model of LSSC with service capacity and time factors considered. This model aims to minimize the average unit volume operation cost of logistics service integrator and maximize the average satisfaction degree of functional logistics service providers. In order to verify the viability and effectiveness of our model, a specific example is numerically analyzed. Some interesting conclusions are obtained. First, along with the increase of completion time delay coefficient permitted by customers, the possible inserting order volume first increases and then trends to be stable. Second, supply chain performance reaches the best when the volume of inserting order is equal to the surplus volume of the normal operation capacity in mass service process. Third, the larger the normal operation capacity in mass service process is, the bigger the possible inserting order's volume will be. Moreover, compared to increasing the completion time delay coefficient, improving the normal operation capacity of mass service process is more useful. PMID:25276851

  6. Ultrasonographic features of normalization of the pylorus after pyloromyotomy for hypertrophic pyloric stenosis.

    PubMed

    Yoshizawa, J; Eto, T; Higashimoto, Y; Saitou, T; Maie, M

    2001-04-01

    The purpose of this study was to describe the time course, early postoperative changes, and morphologic features of normalization of the pylorus after pyloromyotomy for hypertrophic pyloric stenosis. The subjects were 17 infants (9 boys, 8 girls) who underwent umbilical incision Ramstedt pyloromyotomy. The pyloric muscle mass was measured immediately before the operation and then at intervals from 3 days to 6 months after the operation using a 7.5-MHz ultrasound probe. In longitudinal section, the dorsal part of the pyloric muscle thickened transiently and then thinned to normal values by 5 months after the operation. It was 5.1 +/- 0.8 mm (mean +/- SD) preoperatively, increased to 6.0 +/- 0.3 mm by day 3 after the operation (P <.05), and thinned to 2.8 +/- 0.2 mm by 5 months after the operation. Concomitantly, the length of the pylorus gradually decreased (from 20.1 +/- 2.9 mm preoperatively to 16.9 +/- 2.7 mm by 3 days postoperatively [P <.05] and to less than 15 mm, by 4 months). In transverse section, the muscle normalized as in the longitudinal section. At the site of the incision it was 4.3 +/- 0.4 mm thick preoperatively, thickened to 4.6 +/- 0.4 mm by 3 days after the operation (P <.05), thinned to 2.1 +/- 0.9 mm by 7 days (P <.05), and then increased slightly, but always was less than 3.0 mm. Morphologically, in transverse section, the incised area looked like a wedge by 3 days after the operation. After pyloromyotomy for hypertrophic pyloric stenosis, there is an early transient increase in muscle thickness within the first few postoperative days followed by a slow decrease that reaches normal thickness (<3 mm) by 5 months. This decrease in thickness is accompanied by a gradual decrease in length to 75% of the preoperative value by 5 months. The morphologic features in this normalization are first a wedge (day 3), then a flat tire (days 7 and 14), and finally an elongated ring (5 months). J Pediatr Surg 36:582-586. Copyright 2001 by W.B. Saunders Company.

  7. Thermal Behavior of Aerospace Spur Gears in Normal and Loss-of-Lubrication Conditions

    NASA Technical Reports Server (NTRS)

    Handschuh, Robert F.

    2015-01-01

    Testing of instrumented spur gears operating at aerospace rotorcraft conditions was conducted. The instrumented gears were operated in a normal and in a loss-of-lubrication environment. Thermocouples were utilized to measure the temperature at various locations on the test gears and a test utilized a full-field, high-speed infrared thermal imaging system. Data from thermocouples was recorded during all testing at 1 hertz. One test had the gears shrouded and a second test was run without the shrouds to permit the infrared thermal imaging system to take data during loss-of-lubrication operation. Both tests using instrumented spur gears were run in normal and loss-of-lubrication conditions. Also the result from four other loss-of-lubrication tests will be presented. In these tests two different torque levels were used while operating at the same rotational speed (10000 revolutions per minute).

  8. Thermal Behavior of Aerospace Spur Gears in Normal and Loss-of-Lubrication Conditions

    NASA Technical Reports Server (NTRS)

    Handschuh, Robert F.

    2015-01-01

    Testing of instrumented spur gears operating at aerospace rotorcraft conditions was conducted. The instrumented gears were operated in a normal and in a loss-of-lubrication environment. Thermocouples were utilized to measure the temperature at various locations on the test gears and a test utilized a full-field, high-speed infrared thermal imaging system. Data from thermocouples was recorded during all testing at 1 Hz. One test had the gears shrouded and a second test was run without the shrouds to permit the infrared thermal imaging system to take date during loss-of-lubrication operation. Both tests using instrumented spur gears were run in normal and loss-of-lubrication conditions. Also the result from four other loss-of-lubrication tests will be presented. In these tests two different torque levels were used while operating at the same rotational speed (10000 rpm).

  9. Spitzer Mission Operation System Planning for IRAC Warm-Instrument Characterization

    NASA Technical Reports Server (NTRS)

    Hunt, Joseph C., Jr.; Sarrel, Marc A.; Mahoney, William A.

    2010-01-01

    This paper will describe how the Spitzer Mission Operations System planned and executed the characterization phase between Spitzer's cryogenic mission and its warm mission. To the largest extend possible, the execution of this phase was done with existing processing and procedures. The modifications that were made were in response to the differences of the characterization phase compared to normal phases before and after. The primary two categories of difference are: unknown date of execution due to uncertainty of knowledge of the date of helium depletion, and the short cycle time for data analysis and re-planning during execution. In addition, all of the planning and design had to be done in parallel with normal operations, and we had to transition smoothly back to normal operations following the transition. This paper will also describe the re-planning we had to do following an anomaly discovered in the first days after helium depletion.

  10. Downregulation of external death receptor genes FAS and DR5 in colorectal cancer samples positive for human papillomavirus infection.

    PubMed

    Karbasi, Ashraf; Borhani, Nasim; Daliri, Karim; Kazemi, Bahram; Manoochehri, Mehdi

    2015-06-01

    Human papillomaviruses (HPV) have frequently been detected in colorectal cancer tumor samples, and may play a role in the pathogenesis of colorectal cancer. This study was designed to investigate the presence of DNA and RNA for the high-risk HPV genotypes 16 and 18 in samples of colorectal cancer tumors and adjacent normal tissues. We also investigated the expression of proapoptotic genes in HPV-positive colorectal tumors compared to normal tissue samples. Samples of tumoral and adjacent normal tissues were fresh-frozen, and HPV DNA was identified by nested and semiquantitative PCR. Real time PCR was used to quantitatively compare the expression of HPV-18 E6 and nine proapoptotic genes in HPV-positive tumors and samples of adjacent normal tissue. HPV-16 DNA was found in 10.5% of the tumor samples, and HPV-18 DNA was found in 23.6% of the samples. Real time PCR results showed lower expression of the E6 gene in HPV-positive tumors than in adjacent normal tissue. The expression of two proapoptotic genes, FAS and DR5, was significantly lower in tumor samples than in adjacent normal tissues. HPV infection, especially HPV-18, may play a role in colorectal cancer tumorigenesis by downregulating death receptor genes and interfering with the extrinsic pathway of apoptosis. Copyright © 2015 Elsevier GmbH. All rights reserved.

  11. Incidence and Determinants of Port Occlusions in Cancer Outpatients: A Prospective Cohort Study.

    PubMed

    Milani, Alessandra; Mazzocco, Ketti; Gandini, Sara; Pravettoni, Gabriella; Libutti, Livio; Zencovich, Claudia; Sbriglia, Ada; Pari, Chiara; Magon, Giorgio; Saiani, Luisa

    Normal saline is considered a safe alternative for heparin as a locking solution in totally implantable venous access devices. The incidence rate of partial occlusion with the use of normal saline (easy injection, impossible aspiration) is estimated at 4%. The aim of this study was to investigate determinants of partial occlusions with the use of normal saline solution and the maintenance of positive pressure in the catheter. We enrolled 218 patients with different solid tumors who underwent pharmacologic treatment through the port with different frequencies: from once every week to at least once every month. The port was flushed with normal saline solution keeping a positive pressure in the catheter. We performed 4111 observations and documented normal port functioning in 99% of observations (n = 4057) and partial occlusions in 1% of observations (n = 54). Partial occlusions were significantly associated with frequency of port flushing (P < .05), chemotherapy (P < .001), and blood sample collection (P < .001). The use of positive pressure in addition to normal saline reduces the incidence rate of partial occlusions. The type of treatment, blood sample collection, and treatment schedule are important determinants of partial occlusions. Nurses play a key role in maintaining a functioning port using positive pressure during the flushing techniques. Certain risk factors must be monitored to prevent partial occlusions, and certain patients are more likely to present with port-related problems.

  12. Is emotional memory enhancement preserved in amnestic mild cognitive impairment? Evidence from separating recollection and familiarity.

    PubMed

    Wang, Pengyun; Li, Juan; Li, Huijie; Li, Bing; Jiang, Yang; Bao, Feng; Zhang, Shouzi

    2013-11-01

    This study investigated whether the observed absence of emotional memory enhancement in recognition tasks in patients with amnestic mild cognitive impairment (aMCI) could be related to their greater proportion of familiarity-based responses for all stimuli, and whether recognition tests with emotional items had better discriminative power for aMCI patients than those with neutral items. In total, 31 aMCI patients and 30 healthy older adults participated in a recognition test followed by remember/know judgments. Positive, neutral, and negative faces were used as stimuli. For overall recognition performance, emotional memory enhancement was found only in healthy controls; they remembered more negative and positive stimuli than neutral ones. For "remember" responses, we found equivalent emotional memory enhancement in both groups, though a greater proportion of "remember" responses was observed in normal controls. For "know" responses, aMCI patients presented a larger proportion than normal controls did, and their "know" responses were not affected by emotion. A negative correlation was found between emotional enhancement effect and the memory performance related to "know" responses. In addition, receiver operating characteristic curve analysis revealed higher diagnostic accuracy for recognition test with emotional stimuli than with neutral stimuli. The present results implied that the absence of the emotional memory enhancement effect in aMCI patients might be related to their tendency to rely more on familiarity-based "know" responses for all stimuli. Furthermore, recognition memory tests using emotional stimuli may be better able than neutral stimuli to differentiate people with aMCI from cognitively normal older adults. PsycINFO Database Record (c) 2013 APA, all rights reserved.

  13. Current STEREO Status on the Far Side of the Sun

    NASA Astrophysics Data System (ADS)

    Thompson, William T.; Gurman, Joseph; Ossing, Daniel; Luhmann, Janet; Curtis, David; Schroeder, Peter; Mewaldt, Richard; Davis, Andrew; Wortman, Kristin; Russell, Christopher; Galvin, Antoinette; Kistler, Lynn; Ellis, Lorna; Howard, Russell; Vourlidas, Angelos; Rich, Nathan; Hutting, Lynn; Maksimovic, Milan; Bale, Stuart D.; Goetz, Keith

    2015-04-01

    The current positions of the two STEREO spacecraft on the opposite side of the Sun from Earth (superior solar conjunction) has forced some significant changes in the spacecraft and instrument operations. No communications are possible when the spacecraft is within 2 degrees of the Sun, requiring that the spacecraft be put into safe mode until communications can be restored. Unfortunately, communications were lost with the STEREO Behind spacecraft on October 1, 2014, during testing for superior solar conjunction operations. We will discuss what is known about the causes of loss of contact, the steps being taken to try to recover the Behind spacecraft, and what has been done to prevent a similar occurrence on STEREO Ahead.We will also discuss the effect of being on the far side of the Sun on the science operations of STEREO Ahead. Starting on August 20, 2014, the telemetry rate from the STEREO Ahead spacecraft has been tremendously reduced due to the need to keep the temperature of the feed horn on the high gain antenna below acceptable limits. However, the amount of telemetry that can be brought down has been highly reduced. Even so, significant science is still possible from STEREO's unique position on the solar far side. We will discuss the science and space weather products that are, or will be, available from each STEREO instrument, when those products will be available, and how they will be used. Some data, including the regular space weather beacon products, are brought down for an average of a few hours each day during the daily real-time passes, while the in situ and radio beacon data are being stored on the onboard recorder to provide a continuous 24-hour coverage for eventual downlink once the spacecraft is back to normal operations.

  14. 34 CFR 110.12 - Exceptions to the rules against age discrimination: Normal operation or statutory objective of...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 34 Education 1 2010-07-01 2010-07-01 false Exceptions to the rules against age discrimination: Normal operation or statutory objective of any program or activity. 110.12 Section 110.12 Education Regulations of the Offices of the Department of Education OFFICE FOR CIVIL RIGHTS, DEPARTMENT OF EDUCATION...

  15. Interferons and Alphavirus Pathogenesis: Implications for Developing Medical Countermeasures

    DTIC Science & Technology

    2005-12-01

    respiratory tract with Venezuelan equine encephalomyelitis virus in normal and operated Macaca rhesus monkeys. II. Results of histological examination... respiratory tract with Venezuelan equine encephalomyelitis virus in normal and operated Macaca rhesus monkeys. I. Results of virological examination. Acta...alphavirus family: Venezuelan equine encephalitis virus (VEEV), eastern equine encephalitis virus (EEEV), and western equine encephalitis virus (WEEV). I

  16. 26 CFR 1.993-2 - Definition of qualified export assets.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... within the current normal operating cycle of the trade or business of the DISC whose satisfaction when... current normal operating cycle of the trade or business of the DISC, an amount reasonably needed to meet... corporation are— (1) Export property as defined in § 1.993-3 (see paragraph (b) of this section), (2) Business...

  17. 45 CFR 91.13 - Exceptions to the rules against age discrimination: Normal operation or statutory objective of...

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... objective of any program or activity. A recipient is permitted to take an action, otherwise prohibited by...: Normal operation or statutory objective of any program or activity. 91.13 Section 91.13 Public Welfare DEPARTMENT OF HEALTH AND HUMAN SERVICES GENERAL ADMINISTRATION NONDISCRIMINATION ON THE BASIS OF AGE IN...

  18. Preliminary assessment of accident-tolerant fuels on LWR performance during normal operation and under DB and BDB accident conditions

    NASA Astrophysics Data System (ADS)

    Ott, L. J.; Robb, K. R.; Wang, D.

    2014-05-01

    Following the severe accidents at the Japanese Fukushima Daiichi Nuclear Power Station in 2011, the US Department of Energy initiated research and development on the enhancement of the accident tolerance of light water reactors by the development of fuels/cladding that, in comparison with the standard UO2/Zircaloy (Zr) system, can tolerate loss of active cooling in the core for a considerably longer time period while maintaining or improving the fuel performance during normal operations. Analyses are presented that illustrate the impact of these new candidate fuel/cladding materials on the fuel performance at normal operating conditions and on the reactor system under DB and BDB accident conditions.

  19. Electrical and mechanical characteristics of fully transparent IZO thin-film transistors on stress-relieving bendable substrates

    NASA Astrophysics Data System (ADS)

    Park, Sukhyung; Cho, Kyoungah; Oh, Hyungon; Kim, Sangsig

    2016-10-01

    In this study, we report the electrical and mechanical characteristics of fully transparent indium zinc oxide (IZO) thin-film transistors (TFTs) fabricated on stress-relieving bendable substrates. An IZO TFT on a stress-relieving substrate can operate normally at a bending radius of 6 mm, while an IZO TFT on a normal plastic substrate fails to operate normally at a bending radius of 15 mm. A plastic island with high Young's modulus embedded on a soft elastomer layer with low Young's modulus plays the role of a stress-relieving substrate for the operation of the bent IZO TFT. The stress and strain distributions over the IZO TFT will be analyzed in detail in this paper.

  20. Parameter study on the influence of prepressurization on PWR fuel rod behavior during normal operation and hypothetical LOCAs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brzoska, B.; Depisch, F.; Fuchs, H.P.

    To analyze the influence of prepressurization on fuel rod behavior, a parametric study has been performed that considers the effects of as-fabricated fuel rod internal prepressure on the normal operation and postulated loss-of-coolant accident (LOCA) rod behavior of a 1300-MW(electric) Kraftwerk Union (KWU) standard pressurized water reactor nuclear power plant. A variation of the prepressure in the range from 15 to 35 bars has only a slight influence on normal operation behavior. Considering the LOCA behavior, only a small temperature increase results from prepressure reduction, while the core-wide straining behavior is improved significantly. The KWU prepressurization takes both conditions intomore » account.« less

  1. Integrate Thermal Modules for Cooling Silicon and Silicon Carbide Power Modules

    DTIC Science & Technology

    2007-06-01

    currently valid OMB control number. 1 . REPORT DATE 11 JUN 2007 2 . REPORT TYPE N/A 3. DATES COVERED - 4. TITLE AND SUBTITLE Integrate Thermal...vehicle operation as follows: 1 ) Normal Operation at High Speed 2 ) Normal Operation at Low Speed 3) Acceleration at High Speed 4) Acceleration at Low...diodes. For a basis of comparing the performance of the ITMs, we are using the Semikron 100 kW SKAI inverter (fig 1 ) to quantify and generate

  2. The Data Egg: A new solution to text entry barriers

    NASA Technical Reports Server (NTRS)

    Friedman, Gary L.

    1993-01-01

    A unit that allows text entry with only one hand has been developed, and holds the promise of allowing computers to be truly portable. It is unique in that it allows operation in any position, freeing the user from the traditional constraints of having to be seated near a desk. This hand held, chord-key-based unit can be used either autonomously for idea capturing, or tethered to a personal computer and used as an auxiliary keyboard. Astronauts, journalists, the bedridden, and anyone else normally barred from using a computer while on the job could also benefit from this form of man-machine interface, which has been dubbed the 'Data Egg'.

  3. [Displacement and tissue remodeling of temporomandibular joint disc].

    PubMed

    Wang, M Q

    2017-03-09

    Sounding takes the highest prevalence of the signs of temporomandibular disorders (TMD). The well accepted theory of the mechanism for temporomandibular joint (TMJ) sounding is the internal derangement typically characterized by disc displacement. However, according to literature, there are approximately one third of asymptomatic joints in population had disc displacement, and, on the other hand, there are one fourth of TMJ sounding patients had not signs or very limited signs of disc displacement. Replacing the displaced disc to the normal position via methods like surgical operation did not achieve satisfactory long-term outcomes. In this review, we discuss and analyze the possible remodeling of the joint disc displacement diagnosed with imaging based on the anatomy and pathophysiology.

  4. [Gastric stromal tumor treated by laparoscopic surgery].

    PubMed

    Alecu, L; Costan, I; Vitalariu, A; Obrocea, F; Păcuraru, Elena; Gulinescu, L

    2002-01-01

    The authors describe a 59 years old female patient, with a gastrointestinal stromal tumor located on the posterior wall of the gastric funds, who was treated successfully by laparoscopic wedge resection (with clear resection margins), through an anteriorly placed gastrotomy, thus allowing an endoscopic linear cutter Endo GIA, to excise the tumor with a cuff of normal gastric tissue. The anterior gastrotomy was performed with Ultra-Shears. Delivery of the tumor through the gastrotomy is essential for success. The operative time was 110 minutes. The tumor was diagnosed as a gastrointestinal stromal submucosal tumor (of low-grade malignancy) and immunohistochemicaly, this tumor was positive for CD 34. Posterior gastric tumor can be removed using laparoscopic surgery.

  5. Magnetic switch for reactor control rod. [LMFBR

    DOEpatents

    Germer, J.H.

    1982-09-30

    A magnetic reed switch assembly is described for activating an electromagnetic grapple utilized to hold a control rod in position above a reactor core. In normal operation the magnetic field of a permanent magnet is short-circuited by a magnetic shunt, diverting the magnetic field away from the reed switch. The magnetic shunt is made of a material having a Curie-point at the desired release temperature. Above that temperature the material loses its ferromagnetic properties, and the magnetic path is diverted to the reed switch which closes and short-circuits the control circuit for the control rod electro-magnetic grapple which allows the control rod to drop into the reactor core for controlling the reactivity of the core.

  6. Magnetic switch for reactor control rod

    DOEpatents

    Germer, John H.

    1986-01-01

    A magnetic reed switch assembly for activating an electromagnetic grapple utilized to hold a control rod in position above a reactor core. In normal operation the magnetic field of a permanent magnet is short-circuited by a magnetic shunt, diverting the magnetic field away from the reed switch. The magnetic shunt is made of a material having a Curie-point at the desired release temperature. Above that temperature the material loses its ferromagnetic properties, and the magnetic path is diverted to the reed switch which closes and short-circuits the control circuit for the control rod electromagnetic grapple which allows the control rod to drop into the reactor core for controlling the reactivity of the core.

  7. 49 CFR 236.746 - Feature, restoring.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Feature, restoring. An arrangement on an electro-pneumatic switch by means of which power is applied to restore the switch movement to full normal or to full reverse position, before the driving bar creeps sufficiently to unlock the switch, with control level in normal or reverse position. [49 FR 3388, Jan. 26, 1984] ...

  8. Prevalence of Colour Vision Anomalies Amongst Dental Professionals and its Effect on Shade Matching of Teeth

    PubMed Central

    Maini, Anuj Paul; Wangoo, Anuj; Singh, Sukhman; Mehar, Damanpreet Kaur

    2017-01-01

    Abstract Introduction The success of a restoration is dependent on accurate shade matching of teeth leading to studies evaluating the factors affecting the perception of shades. Colour vision anomalies including colour blindness have been found to exist in the population and it has been thought to be a potential factor affecting the colour perception ability. Aim The present study was done to evaluate the prevalence of colour vision anomalies and its effect on matching of shades of teeth. Materials and Methods A total of 147 dental professionals were randomly selected for the study and were first tested for visual acuity using the Snellen’s Eye Chart so as to carry on the study with only those operators who had a vision of 6/6. Then, the Ishihara’s colour charts were used to test the operators for colour vision handicap. In the last stage of the study, test for accuracy of shade selection was done using the Vitapan Classical shade guide. The shade guide tabs were covered to avoid bias. Percentage was used to calculate the prevalence of colour vision handicap and its effect on matching of shades of teeth as compared to normal vision, which was evaluated using Chi square test. Results Nineteen operators had colour vision anomalies out of hundred operators and only two operators presented with colour blindness. Colour vision anomaly was more prevalent than colour blindness and it was also found that it was more prevalent in males than females. The difference between the accuracy of shade matching between the operators with normal vision and colour vision defect and operators with normal vision and colour blindness was statistically not significant. Conclusion Colour blindness and colour vision handicap are rare conditions, with the latter being more common in the population. According to our study, it was concluded that no statistically significant difference existed amongst the operators with normal vision and colour vision anomaly or operators with normal vision and colour blindness during the matching of shades of teeth. PMID:28274040

  9. 49 CFR 195.406 - Maximum operating pressure.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... HAZARDOUS LIQUIDS BY PIPELINE Operation and Maintenance § 195.406 Maximum operating pressure. (a) Except for surge pressures and other variations from normal operations, no operator may operate a pipeline at a... 49 Transportation 3 2010-10-01 2010-10-01 false Maximum operating pressure. 195.406 Section 195...

  10. 49 CFR 195.406 - Maximum operating pressure.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... HAZARDOUS LIQUIDS BY PIPELINE Operation and Maintenance § 195.406 Maximum operating pressure. (a) Except for surge pressures and other variations from normal operations, no operator may operate a pipeline at a... 49 Transportation 3 2012-10-01 2012-10-01 false Maximum operating pressure. 195.406 Section 195...

  11. 49 CFR 195.406 - Maximum operating pressure.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... HAZARDOUS LIQUIDS BY PIPELINE Operation and Maintenance § 195.406 Maximum operating pressure. (a) Except for surge pressures and other variations from normal operations, no operator may operate a pipeline at a... 49 Transportation 3 2014-10-01 2014-10-01 false Maximum operating pressure. 195.406 Section 195...

  12. 49 CFR 195.406 - Maximum operating pressure.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... HAZARDOUS LIQUIDS BY PIPELINE Operation and Maintenance § 195.406 Maximum operating pressure. (a) Except for surge pressures and other variations from normal operations, no operator may operate a pipeline at a... 49 Transportation 3 2011-10-01 2011-10-01 false Maximum operating pressure. 195.406 Section 195...

  13. 49 CFR 195.406 - Maximum operating pressure.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... HAZARDOUS LIQUIDS BY PIPELINE Operation and Maintenance § 195.406 Maximum operating pressure. (a) Except for surge pressures and other variations from normal operations, no operator may operate a pipeline at a... 49 Transportation 3 2013-10-01 2013-10-01 false Maximum operating pressure. 195.406 Section 195...

  14. 78 FR 22576 - Application and Amendment to Facility Operating License Involving Proposed No Significant Hazards...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-04-16

    ... Facility Operating License Involving Proposed No Significant Hazards Consideration Determination; San... Operating License No. NPF-10, issued to Southern California Edison (SCE, the licensee), for operation of the... operating conditions'' and ``normal steady state full power operation'' and restricts operation to 70...

  15. The Nimbus 6 data catalog. Volume 6: Data orbits 4339 through 5155. [from May through June 1976

    NASA Technical Reports Server (NTRS)

    1977-01-01

    Satellite operations from launch through 14 July (orbit 425) consisted of engineering evaluation of all spacecraft systems. As a result of that effort, data reception, accountability and processing were intermittent during that period. During orbit 4905 (12 June), Nimbus 6 successfully completed one year operations. A summary of the documentation for each Nimbus 6 Data Catalog volume is presented. The pitch of the Nimbus 6 satellite has been made to alternate between +2.0 degrees, +0.6 degrees, and 0.0 degrees since launch. A positive pitch angle of 0.6 degrees moves the nadir-looking position 11.5 kilometers ahead of the subsatellite point. A positive pitch angle of 2.0 degrees moves the nadir-looking position 38.3 kilometers ahead of the subsatellite point. At these pitch angles, a scanner-type instrument no longer scans the earth along a great circle arc through the subpoint, but scans along the small circle formed by the intersection of the scan plane with the earth. Since the plane of the small circle is tilted with respect to the nominal scan plane, points on the arc are displaced farther from the great circle as the scan angle increases. As noted above, a pitch angle of 0.6 degrees causes a displacement of 11.5 kilometers at nadir, but when the scanner turns 45 degrees away from nadir the displacement increases slightly to 12.8 kilometers. Similarly, for a 2.0 degree pitch the displacement is 38.3 kilometers at nadir and increases to 42.6 kilometers at a 45 degree scan angle. Thus, although the instrument records in lines normal to the orbit plane (in the absence of yaw) the perpendicular displacement from the perfect-attitude scan line is not uniform across the scan line.

  16. Comparison for aphasic and control subjects of eye movements hypothesized in neurolinguistic programming.

    PubMed

    Dooley, K O; Farmer, A

    1988-08-01

    Neurolinguistic programming's hypothesized eye movements were measured independently using videotapes of 10 nonfluent aphasic and 10 control subjects matched for age and sex. Chi-squared analysis indicated that eye-position responses were significantly different for the groups. Although earlier research has not supported the hypothesized eye positions for normal subjects, the present findings support the contention that eye-position responses may differ between neurologically normal and aphasic individuals.

  17. A prospective single center study to assess the impact of surgical stabilization in patients with rib fracture.

    PubMed

    Khandelwal, Gaurav; Mathur, R K; Shukla, Sumit; Maheshwari, Ankur

    2011-01-01

    To compare the intensity of pain and duration of return to normal activity in patients with rib fractures treated with surgical stabilization with plating versus conventional treatment modalities. This study was conducted over a 12 month period. Patients with rib fractures were assessed by numerical pain scale. Patients having pain scale less than 5 were excluded from study. Patients having pain scale of 5 or more than 5 were treated with conventional treatment for next 10 days. On 11th day patients were again assessed by numerical pain scale and patients having score less than 5 were excluded from study. Patients having pain scale of 5, 6, and 7 were treated with conventional treatment and patients having pain scale of 8, 9, and 10 were selected for operative management. Operative and control group were compared on basis of intensity of pain and duration of return to normal activity. Follow up was done on 5, 15, and 30 post operative day. There was less pain in operative group as compared to control group. Mean rib fracture pain in operative group was 9.15, 2.31, 1.12 as compared to 6.25, 5.96, 4.50 in control group on 5, 15 and 30 post operative days. Also there was early return to normal activity in operative group. Surgical stabilization of rib fracture, an underutilized intervention is better than conventional conservative management in terms of both, decrease in intensity of pain and early return to normal activity. Copyright © 2011 Surgical Associates Ltd. Published by Elsevier Ltd. All rights reserved.

  18. Welfare effects of reduced milk production associated with Johne's disease on Johne's-positive versus Johne's-negative dairy operations.

    PubMed

    Losinger, Willard C

    2006-08-01

    An examination of the economic impacts of reduced milk production associated with Johne's disease on Johne's-positive and Johne's-negative dairy operations indicated that, if Johne's disease had not existed in US dairy cows in 1996, then the economic surplus of Johne's-negative operations would have been $600 million+/-$530 million lower, while the economic surplus of Johne's-positive operations would have been higher by $28 million+/-$79 million, which was not significantly different from zero. The data available for projecting changes in surplus were not sufficiently precise to allow an exact statement on whether Johne's-positive operations would have been better or worse off economically, in terms of the value received for producing more milk if they had not been affected by Johne's disease. The changes in producer surplus, based upon eliminating specific epidemiological risk factors for Johne's disease, were disaggregated between Johne's-positive dairy operations exposed to the risk factor and all other US dairy operations. Eliminating the risk factor of having any cows not born on the operation would have had a significant positive effect on the economic surplus of Johne's-positive operations that had any cows not born on the operation.

  19. Comparison of exercises inducing maximum voluntary isometric contraction for the latissimus dorsi using surface electromyography.

    PubMed

    Park, Se-yeon; Yoo, Won-gyu

    2013-10-01

    The aim of this study was to compare muscular activation during five different normalization techniques that induced maximal isometric contraction of the latissimus dorsi. Sixteen healthy men participated in the study. Each participant performed three repetitions each of five types of isometric exertion: (1) conventional shoulder extension in the prone position, (2) caudal shoulder depression in the prone position, (3) body lifting with shoulder depression in the seated position, (4) trunk bending to the right in the lateral decubitus position, and (5) downward bar pulling in the seated position. In most participants, maximal activation of the latissimus dorsi was observed during conventional shoulder extension in the prone position; the percentage of maximal voluntary contraction was significantly greater for this exercise than for all other normalization techniques except downward bar pulling in the seated position. Although differences in electrode placement among various electromyographic studies represent a limitation, normalization techniques for the latissimus dorsi are recommended to minimize error in assessing maximal muscular activation of the latissimus dorsi through the combined use of shoulder extension in the prone position and downward pulling. Copyright © 2013 Elsevier Ltd. All rights reserved.

  20. Identifying Otosclerosis with Aural Acoustical Tests of Absorbance, Group Delay, Acoustic Reflex Threshold, and Otoacoustic Emissions.

    PubMed

    Keefe, Douglas H; Archer, Kelly L; Schmid, Kendra K; Fitzpatrick, Denis F; Feeney, M Patrick; Hunter, Lisa L

    2017-10-01

    Otosclerosis is a progressive middle-ear disease that affects conductive transmission through the middle ear. Ear-canal acoustic tests may be useful in the diagnosis of conductive disorders. This study addressed the degree to which results from a battery of ear-canal tests, which include wideband reflectance, acoustic stapedius muscle reflex threshold (ASRT), and transient evoked otoacoustic emissions (TEOAEs), were effective in quantifying a risk of otosclerosis and in evaluating middle-ear function in ears after surgical intervention for otosclerosis. To evaluate the ability of the test battery to classify ears as normal or otosclerotic, measure the accuracy of reflectance in classifying ears as normal or otosclerotic, and evaluate the similarity of responses in normal ears compared with ears after surgical intervention for otosclerosis. A quasi-experimental cross-sectional study incorporating case control was used. Three groups were studied: one diagnosed with otosclerosis before corrective surgery, a group that received corrective surgery for otosclerosis, and a control group. The test groups included 23 ears (13 right and 10 left) with normal hearing from 16 participants (4 male and 12 female), 12 ears (7 right and 5 left) diagnosed with otosclerosis from 9 participants (3 male and 6 female), and 13 ears (4 right and 9 left) after surgical intervention from 10 participants (2 male and 8 female). Participants received audiometric evaluations and clinical immittance testing. Experimental tests performed included ASRT tests with wideband reference signal (0.25-8 kHz), reflectance tests (0.25-8 kHz), which were parameterized by absorbance and group delay at ambient pressure and at swept tympanometric pressures, and TEOAE tests using chirp stimuli (1-8 kHz). ASRTs were measured in ipsilateral and contralateral conditions using tonal and broadband noise activators. Experimental ASRT tests were based on the difference in wideband-absorbed sound power before and after presenting the activator. Diagnostic accuracy to classify ears as otosclerotic or normal was quantified by the area under the receiver operating characteristic curve (AUC) for univariate and multivariate reflectance tests. The multivariate predictor used a small number of input reflectance variables, each having a large AUC, in a principal components analysis to create independent variables and followed by a logistic regression procedure to classify the test ears. Relative to the results in normal ears, diagnosed otosclerosis ears more frequently showed absent TEOAEs and ASRTs, reduced ambient absorbance at 4 kHz, and a different pattern of tympanometric absorbance and group delay (absorbance increased at 2.8 kHz at the positive-pressure tail and decreased at 0.7-1 kHz at the peak pressure, whereas group delay decreased at positive and negative-pressure tails from 0.35-0.7 kHz, and at 2.8-4 kHz at positive-pressure tail). Using a multivariate predictor with three reflectance variables, tympanometric reflectance (AUC = 0.95) was more accurate than ambient reflectance (AUC = 0.88) in classifying ears as normal or otosclerotic. Reflectance provides a middle-ear test that is sensitive to classifying ears as otosclerotic or normal, which may be useful in clinical applications. American Academy of Audiology

  1. Real-time graphic display utility for nuclear safety applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yang, S.; Huang, X.; Taylor, J.

    2006-07-01

    With the increasing interests in the nuclear energy, new nuclear power plants will be constructed and licensed, and older generation ones will be upgraded for assuring continuing operation. The tendency of adopting the latest proven technology and the fact of older parts becoming obsolete have made the upgrades imperative. One of the areas for upgrades is the older CRT display being replaced by the latest graphics displays running under modern real time operating system (RTOS) with safety graded modern computer. HFC has developed a graphic display utility (GDU) under the QNX RTOS. A standard off-the-shelf software with a long historymore » of performance in industrial applications, QNX RTOS used for safety applications has been examined via a commercial dedication process that is consistent with the regulatory guidelines. Through a commercial survey, a design life cycle and an operating history evaluation, and necessary tests dictated by the dedication plan, it is reasonably confirmed that the QNX RTOS was essentially equivalent to what would be expected in the nuclear industry. The developed GDU operates and communicates with the existing equipment through a dedicated serial channel of a flat panel controller (FPC) module. The FPC module drives a flat panel display (FPD) monitor. A touch screen mounted on the FPD serves as the normal operator interface with the FPC/FPD monitor system. The GDU can be used not only for replacing older CRTs but also in new applications. The replacement of the older CRT does not disturb the function of the existing equipment. It not only provides modern proven technology upgrade but also improves human ergonomics. The FPC, which can be used as a standalone controller running with the GDU, is an integrated hardware and software module. It operates as a single board computer within a control system, and applies primarily to the graphics display, targeting, keyboard and mouse. During normal system operation, the GDU has two sources of data input: a serial interface with field equipment and a serial input from the FPD touch screen. The mechanism for data collection from the field equipment consists of the regular exchange of the data update request messages and target commands sent to the equipment and the update messages returned to the FPC. The data updates from field equipment control displays presented on the graphic pages. Touch screen contacts are decoded to identify physical position that was contacted. If that position corresponds with one of the buttons on the graphic page, the software uses that input to initiate the function defined for the particular button contacted. In this paper, the FPC will be illustrated as a standalone system as well as a module in a dedicated control system. The GDU design concepts and its design flow will be demonstrated. The dedication process of the QNX RTOS needed for the GDU will be highlighted. Finally, the GDU with a specific application example used in one of the nuclear power plants will be presented. (authors)« less

  2. 49 CFR 193.2503 - Operating procedures.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ...: FEDERAL SAFETY STANDARDS Operations § 193.2503 Operating procedures. Each operator shall follow one or more manuals of written procedures to provide safety in normal operation and in responding to an... 49 Transportation 3 2013-10-01 2013-10-01 false Operating procedures. 193.2503 Section 193.2503...

  3. 49 CFR 193.2503 - Operating procedures.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ...: FEDERAL SAFETY STANDARDS Operations § 193.2503 Operating procedures. Each operator shall follow one or more manuals of written procedures to provide safety in normal operation and in responding to an... 49 Transportation 3 2011-10-01 2011-10-01 false Operating procedures. 193.2503 Section 193.2503...

  4. 49 CFR 193.2503 - Operating procedures.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ...: FEDERAL SAFETY STANDARDS Operations § 193.2503 Operating procedures. Each operator shall follow one or more manuals of written procedures to provide safety in normal operation and in responding to an... 49 Transportation 3 2014-10-01 2014-10-01 false Operating procedures. 193.2503 Section 193.2503...

  5. 49 CFR 193.2503 - Operating procedures.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ...: FEDERAL SAFETY STANDARDS Operations § 193.2503 Operating procedures. Each operator shall follow one or more manuals of written procedures to provide safety in normal operation and in responding to an... 49 Transportation 3 2012-10-01 2012-10-01 false Operating procedures. 193.2503 Section 193.2503...

  6. Detection of EWS/FLI-1 fusion in non-Ewing soft tissue tumors.

    PubMed

    Trancău, I O; Huică, R; Surcel, M; Munteanu, A; Ursaciuc, C

    2015-01-01

    EWS/FLI-1 fusion mainly appears in Ewing's sarcoma or the primitive neuroectodermal tumors and represents a genomic marker for these tumors. However, it can appear with lower frequency in other soft tissue tumors. The paper investigates the presence of EWS/FLI-1 fusion in clinically diagnosed sarcoma belonging to different non-Ewing connective tissue tumors in order to search for a possible new biomarker valuable for investigators. 20 patients with soft tissue tumors, who underwent surgery, were tested. Intra-operative samples of normal and tumor tissue were collected for histopathological diagnosis and genetics determinations. The patients' RNA from tumor and normal peritumoral tissue was extracted and EWS/FLI-1 fusion screened by quantitative real-time PCR. The relative expression of the fusion in the tumor sample was compared to the similar expression in normal tissue. The amplification in the threshold zone was shown by 5 samples (25%): 2 clear cell sarcoma, 1 fibrosarcoma, 1 malignant tumor of nerve sheath, 1 metastatic adenocarcinoma. We differentiated between the unspecific amplification and concluded that these are weak positive results. Genomic investigation may establish the tumor malignancy and its possible affiliation earlier than histopathology. It can support the screening of EWS/FLI-1 fusion in a larger variety of clinically diagnosed soft tissue tumors.

  7. 40 CFR 63.2850 - How do I comply with the hazardous air pollutant emission standards?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...) Periodic SSM reports in accordance with § 63.2861(c). (iii) Immediate SSM reports in accordance with § 63... and table 1 of this section for sources under normal operation, and the schedules for demonstrating compliance for existing sources under normal operation in table 2 of this section. (c) New sources. Your new...

  8. 40 CFR 63.2850 - How do I comply with the hazardous air pollutant emission standards?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... accordance with § 63.2861(a). (ii) Periodic SSM reports in accordance with § 63.2861(c). (iii) Immediate SSM... paragraph (a) of this section and table 1 of this section for sources under normal operation, and the schedules for demonstrating compliance for existing sources under normal operation in table 2 of this...

  9. 40 CFR 63.2850 - How do I comply with the hazardous air pollutant emission standards?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... accordance with § 63.2861(a). (ii) Periodic SSM reports in accordance with § 63.2861(c). (iii) Immediate SSM... paragraph (a) of this section and table 1 of this section for sources under normal operation, and the schedules for demonstrating compliance for existing sources under normal operation in table 2 of this...

  10. 40 CFR 63.2850 - How do I comply with the hazardous air pollutant emission standards?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... accordance with § 63.2861(a). (ii) Periodic SSM reports in accordance with § 63.2861(c). (iii) Immediate SSM... paragraph (a) of this section and table 1 of this section for sources under normal operation, and the schedules for demonstrating compliance for existing sources under normal operation in table 2 of this...

  11. 40 CFR 63.2850 - How do I comply with the hazardous air pollutant emission standards?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...) Periodic SSM reports in accordance with § 63.2861(c). (iii) Immediate SSM reports in accordance with § 63... and table 1 of this section for sources under normal operation, and the schedules for demonstrating compliance for existing sources under normal operation in table 2 of this section. (c) New sources. Your new...

  12. 18 CFR 1309.6 - Is the normal operation or statutory objective of any program or activity an exception to the...

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 18 Conservation of Power and Water Resources 2 2011-04-01 2011-04-01 false Is the normal operation... discrimination? 1309.6 Section 1309.6 Conservation of Power and Water Resources TENNESSEE VALLEY AUTHORITY... activity an exception to the rules against age discrimination? A recipient is permitted to take an action...

  13. 18 CFR 1309.6 - Is the normal operation or statutory objective of any program or activity an exception to the...

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 18 Conservation of Power and Water Resources 2 2010-04-01 2010-04-01 false Is the normal operation... discrimination? 1309.6 Section 1309.6 Conservation of Power and Water Resources TENNESSEE VALLEY AUTHORITY... activity an exception to the rules against age discrimination? A recipient is permitted to take an action...

  14. 75 FR 78985 - County of DuPage; Notice of Preliminary Permit Application Accepted for Filing and Soliciting...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-12-17

    ... (upper reservoir) having a total storage capacity of 8,145 acre- feet at a normal maximum operating... reservoir) 250 feet below the bottom of the upper reservoir having a total/usable storage capacity of 7,465 acre-feet at normal maximum operation elevation of 210 feet msl; (5) a powerhouse with approximate...

  15. In vitro tympanic membrane position identification with a co-axial fiber-optic otoscope

    NASA Astrophysics Data System (ADS)

    Sundberg, Mikael; Peebo, Markus; Strömberg, Tomas

    2011-09-01

    Otitis media diagnosis can be assisted by measuring the shape of the tympanic membrane. We have developed an ear speculum for an otoscope, including spatially distributed source and detector optical fibers, to generate source-detector intensity matrices (SDIMs), representing the curvature of surfaces. The surfaces measured were a model ear with a latex membrane and harvested temporal bones including intact tympanic membranes. The position of the tympanic membrane was shifted from retracted to bulging by air pressure and that of the latex membrane by water displacement. The SDIM was normalized utilizing both external (a sheared flat plastic cylinder) and internal references (neutral position of the membrane). Data was fitted to a two-dimensional Gaussian surface representing the shape by its amplitude and offset. Retracted and bulging surfaces were discriminated for the model ear by the sign of the Gaussian amplitude for both internal and external reference normalization. Tympanic membranes were separated after a two-step normalization: first to an external reference, adjusted for the distance between speculum and the surfaces, and second by comparison with an average normally positioned SDIM from tympanic membranes. In conclusion, we have shown that the modified otoscope can discriminate between bulging and retracted tympanic membranes in a single measurement, given a two-step normalization.

  16. PC-402 Pioneer Venus orbiter spacecraft mission operational characteristics document

    NASA Technical Reports Server (NTRS)

    Barker, F. C.; Butterworth, L. W.; Daniel, R. E.; Drean, R. J.; Filetti, K. A.; Fisher, J. N.; Nowak, L. A.; Porzucki, J.; Salvatore, J. O.; Tadler, G. A.

    1978-01-01

    The operational characteristics of the Orbiter spacecraft and its subsystems are described. In extensive detail. Description of the nominal phases, system interfaces, and the capabilities and limitations of system level performance are included along with functional and operational descriptions at the subsystem and unit level the subtleties of nominal operation as well as detailed capabilities and limitations beyond nominal performance are discussed. A command and telemetry logic flow diagram for each subsystem is included. Each diagram encountered along each command signal path into, and each telemetry signal path out of the subsystem. Normal operating modes that correspond to the performance of specific functions at the time of specific events in the mission are also discussed. Principal backup means of performing the normal Orbiter operating modes are included.

  17. Fast, automatically darkening welding filter offering an improved level of safety.

    PubMed

    Palmer, S

    1996-03-01

    A mode of operation is introduced for the standard 90° twisted nematic (TN) liquid-crystal cell when placed together with an interference filter and positioned between crossed polarizers such that a small stimulating voltage of between ±2.0 and ±13.0 V is required in order to attain the light state. Further incrementation of the driving electronics reverts the system back to a darker phase. Such cells offer advantages over those of the standard 90° TN device operating in the normally white mode, in that the unit maintains the fast response time from the light to the dark state associated with the employment of TN cells placed between crossed polarizers. In addition, a low transmittance state is achieved when the unit is in the inactivated phase; this is an effect usually correlated with the normally black mode of operation. These cells are therefore ideal candidates for incorporation into fast, automatically darkening, welding filters that are designed to change rapidly from the light to the dark protective state, while offering an improved level of safety by not holding in a potentially hazardous light state should the controlling electronics malfunction. The requirement for this phenomenon to be observed is that the cell displays a low optical transmittance over the green wavelengths of the visible spectrum when in the inactivated phase and placed between crossed polarizers. The presence of an interference filter that possesses a peak transmittance over the central part of the visible spectrum is also necessary. It is shown that there are only two possible cell types that satisfy this criteria, and the optical properties of such cells are analyzed in some detail.

  18. Measurement of urinary metanephrines to screen for pheochromocytoma in an unselected hospital referral population

    PubMed Central

    Brain, Keith L.; Kay, Jonathan; Shine, Brian

    2009-01-01

    Background Despite the rarity of pheochromocytoma, the dangers of uncontrolled severe hypertension and the very effective surgical treatment of this condition mean that diagnosis is important. Urinary or plasma catecholamines or catecholamine-derivatives are commonly used to screen for pheochromocytomas prior to imaging. This study investigates whether derived measures obtained from 24-hour urinary metanephrine results, patient age and sex can better predict tumors in populations with a low pre-test probability. Methods This study takes a pragmatic approach by retrospectively studying the outcomes of an unselected population referred for urinary metanephrine testing (1819 patients) to a tertiary hospital laboratory, and investigates the usefulness of some simple derivative measures for detecting pheochromocytoma. Urinary 24-hour excretion of metanephrine, normetanephrine and 3-methoxytyramine were normalized by dividing by an age- and sex- specific reference range. The ability of products of these normalized measures to predict pheochromocytomas was assessed, compared to a gold standard of biopsy-confirmed tumor. Results The normalized product of urinary metanephrine and normetanephrine excretion (nMAD.nNMT) proved to be a highly sensitive (100%) and specific (99.1%) measure yielding a positive predictive value 82%. Receiver-operator characteristic curves were not improved by including the normalized 3-methoxytyramine concentrations in the product. nMAD.nNMT gave higher sensitivity and specificity than either test alone. Conclusion We suggest that nMAD.nNMT is a useful measure for identifying pheochromocytoma in a population with a low pre-test probability. PMID:16990424

  19. Control method for prosthetic devices

    NASA Technical Reports Server (NTRS)

    Bozeman, Richard J., Jr. (Inventor)

    1995-01-01

    A control system and method for prosthetic devices is provided. The control system comprises a transducer for receiving movement from a body part for generating a sensing signal associated with that movement. The sensing signal is processed by a linearizer for linearizing the sensing signal to be a linear function of the magnitude of the distance moved by the body part. The linearized sensing signal is normalized to be a function of the entire range of body part movement from the no-shrug position of the moveable body part. The normalized signal is divided into a plurality of discrete command signals. The discrete command signals are used by typical converter devices which are in operational association with the prosthetic device. The converter device uses the discrete command signals for driving the moveable portions of the prosthetic device and its sub-prosthesis. The method for controlling a prosthetic device associated with the present invention comprises the steps of receiving the movement from the body part, generating a sensing signal in association with the movement of the body part, linearizing the sensing signal to be a linear function of the magnitude of the distance moved by the body part, normalizing the linear signal to be a function of the entire range of the body part movement, dividing the normalized signal into a plurality of discrete command signals, and implementing the plurality of discrete command signals for driving the respective moveable prosthesis device and its sub-prosthesis.

  20. Refraction index sensor based on phase resonances in a subwavelength structure with double period.

    PubMed

    Skigin, Diana C; Lester, Marcelo

    2016-10-01

    In this paper, we numerically demonstrate a refraction index sensor based on phase resonance excitation in a subwavelength-slit structure with a double period. The sensor consists of a metal layer with subwavelength slots arranged in a bi-periodic form, separated from a high refraction index medium. Between the metallic structure and the incident medium, a dielectric waveguide is formed whose refraction index is going to be determined. Variations in the refraction index of the waveguide are detected as shifts in the peaks of transmitted intensity originated by resonant modes supported by the compound metallic structure. At normal incidence, the spectral position of these resonant peaks exhibits a linear or a quadratic dependence with the refraction index, which permits us to obtain the unknown refraction index value with a high precision for a wide range of wavelengths. Since the operating principle of the sensor is due to the morphological resonances of the slits' structure, this device can be scaled to operate in different wavelength ranges while keeping similar characteristics.

  1. Fusion of local and global detection systems to detect tuberculosis in chest radiographs.

    PubMed

    Hogeweg, Laurens; Mol, Christian; de Jong, Pim A; Dawson, Rodney; Ayles, Helen; van Ginneken, Bramin

    2010-01-01

    Automatic detection of tuberculosis (TB) on chest radiographs is a difficult problem because of the diverse presentation of the disease. A combination of detection systems for abnormalities and normal anatomy is used to improve detection performance. A textural abnormality detection system operating at the pixel level is combined with a clavicle detection system to suppress false positive responses. The output of a shape abnormality detection system operating at the image level is combined in a next step to further improve performance by reducing false negatives. Strategies for combining systems based on serial and parallel configurations were evaluated using the minimum, maximum, product, and mean probability combination rules. The performance of TB detection increased, as measured using the area under the ROC curve, from 0.67 for the textural abnormality detection system alone to 0.86 when the three systems were combined. The best result was achieved using the sum and product rule in a parallel combination of outputs.

  2. PI-in-a-box: An expert system to advise astronauts during experiments

    NASA Technical Reports Server (NTRS)

    Young, Laurence R.

    1990-01-01

    Perhaps the scarcest resource for manned flight experiments - on Spacelab or on Space Station Freedom - will continue to be crew time. To maximize the efficiency of the crew, and to make use of their abilities to work as scientist collaborators as well as equipment operators, normally requires more training in a wide variety of disciplines than is practical. The successful application of on-board expert systems, as envisioned by the 'Principal Investigator (PI)-in-a-Box' program, should alleviate the training bottleneck and provide the astronaut with the guidance and coaching needed to permit him or her to operate an experiment according to the desires and knowledge of the PI, despite changes in conditions. In addition to the functions of providing expert devise concerning scheduling and repair, the program should bring the astronaut into the scientific evaluation phase of an experiment by sharing with him the guidance and observations regarding the relevance and importance of data as it is being generated. Initial reaction from the astronaut community has been positive.

  3. Restricted sleep and negative affective states in commercial pilots during short haul operations.

    PubMed

    Drury, D Arthur; Ferguson, Sally A; Thomas, Matthew J W

    2012-03-01

    This study aims to investigate (1) the relationship between restricted sleep and Heightened Emotional Activity (HEA) during normal flight operations, and (2) whether sleep patterns influence the strength of the HEA as a response to threats. Accident investigation reports continue to highlight the relationship between restricted sleep and poor safety outcomes. However, to date we have a limited understanding of how sleep and HEA interact. A total of 302 sectors of normal airline flight operations were observed by trained observers, and instances of heightened emotional activity were recorded. During the cruise phase of each of these sectors, crew members were asked to calculate the amount of sleep they had obtained in previous 24 and 48 h. In the 302 sectors of normal flight operations, 535 instances of HEA were observed. Descriptive analyses of instances of HEA and sleep in the prior 24 and 48 h showed a significant relationship between the occurrence of HEA and recent sleep. The relationship between restricted sleep and HEA suggests that there may well be further implications with respect to operational safety. Copyright © 2011 Elsevier Ltd. All rights reserved.

  4. 40 CFR 190.10 - Standards for normal operations.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ....10 Section 190.10 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) RADIATION PROTECTION PROGRAMS ENVIRONMENTAL RADIATION PROTECTION STANDARDS FOR NUCLEAR POWER OPERATIONS Environmental... operations and to radiation from these operations. (b) The total quantity of radioactive materials entering...

  5. 40 CFR 190.10 - Standards for normal operations.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ....10 Section 190.10 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) RADIATION PROTECTION PROGRAMS ENVIRONMENTAL RADIATION PROTECTION STANDARDS FOR NUCLEAR POWER OPERATIONS Environmental... operations and to radiation from these operations. (b) The total quantity of radioactive materials entering...

  6. [EMG activities of the head, neck and upper trunk muscles with mandibular movements in healthy adults and mandibular asymmetry patients].

    PubMed

    Jiang, Ting; Zhang, Zhenkang; Yang, Zhaohui; Yi, Biao; Feng, Hailan; Wang, Xing

    2002-03-25

    To study the activities of head, neck and upper trunk muscles during mandibular movements in healthy adults and mandibular asymmetry patients. Electromyographic integrogram was used to record and analyze the electromyographic activities of the anterior temporal (Ta), posterior temporal (Tp), sternocleidomastoid (SCM), and trapezius (TRAP) muscles in rest position and during mandibular movement among 10 normal adults and 10 mandibular asymmetry patients. All the four muscles showed constant electromyographic activities when the mandible was in the rest position. The activities of Ta, Tp, and SCM muscles increased with protrusion of mandible, mouth opening, tapping, maximum clenching, and chewing. The activities of Ta and Tp muscles of the patients were 1.7 times greater than that of the normal adults during mandibular movement without occlusion, and were weaker by 50% during mandibular movement with occlusion. The difference between electromyographic activities during mandibular movement and in rest position was less among patients than among normal adults. The TRAP muscle of the patients showed constant electromyographic activities with the activity volume nearly 1.8 times that of the normal adults. The difference between the muscle and its namesake at the opposite side was greater among the patients (21%) than among the normal adults (8%). All the four muscles participate in the maintenance of rest position of mandible and the realization of mandibular movements. The coordination of muscular activities among mandibular asymmetry patients is poorer than that among normal adults.

  7. Identification of novel non-invasive biomarkers of urinary chronic pelvic pain syndrome: findings from the Multidisciplinary Approach to the Study of Chronic Pelvic Pain (MAPP) Research Network.

    PubMed

    Dagher, Adelle; Curatolo, Adam; Sachdev, Monisha; Stephens, Alisa J; Mullins, Chris; Landis, J Richard; van Bokhoven, Adrie; El-Hayek, Andrew; Froehlich, John W; Briscoe, Andrew C; Roy, Roopali; Yang, Jiang; Pontari, Michel A; Zurakowski, David; Lee, Richard S; Moses, Marsha A

    2017-07-01

    To examine a series of candidate markers for urological chronic pelvic pain syndrome (UCPPS), selected based on their proposed involvement in underlying biological processes so as to provide new insights into pathophysiology and suggest targets for expanded clinical and mechanistic studies. Baseline urine samples from Multidisciplinary Approach to the Study of Chronic Pelvic Pain (MAPP) Research Network study participants with UCPPS (n = 259), positive controls (PCs; chronic pain without pelvic pain, n = 107) and healthy controls (HCs, n = 125) were analysed for the presence of proteins that are suggested in the literature to be associated with UCPPS. Matrix metalloproteinase (MMP)-2, MMP-9, MMP-9/neutrophil gelatinase-associated lipocalin (NGAL) complex (also known as Lipocalin 2), vascular endothelial growth factor (VEGF), VEGF receptor 1 (VEGF-R1) and NGAL were assayed and quantitated using mono-specific enzyme-linked immunosorbent assays for each protein. Log-transformed concentration (pg/mL or ng/mL) and concentration normalized to total protein (pg/μg) values were compared among the UCPPS, PC and HC groups within sex using the Student's t-test, with P values adjusted for multiple comparisons. Multivariable logistic regression and receiver-operating characteristic curves assessed the utility of the biomarkers in distinguishing participants with UCPPS and control participants. Associations of protein with symptom severity were assessed by linear regression. Significantly higher normalized concentrations (pg/μg) of VEGF, VEGF-R1 and MMP-9 in men and VEGF concentration (pg/mL) in women were associated with UCPPS vs HC. These proteins provided only marginal discrimination between UCPPS participants and HCs. In men with UCCPS, pain severity was significantly positively associated with concentrations of MMP-9 and MMP-9/NGAL complex, and urinary severity was significantly positively associated with MMP-9, MMP-9/NGAL complex and VEGF-R1. In women with UCPPS, pain and urinary symptom severity were associated with increased normalized concentrations of MMP-9/NGAL complex, while pain severity alone was associated with increased normalized concentrations of VEGF, and urinary severity alone was associated with increased normalized concentrations of MMP-2. Pain severity in women with UCPPS was significantly positively associated with concentrations of all biomarkers except NGAL, and urinary severity with all concentrations except VEGF-R1. Altered levels of MMP-9, MMP-9/NGAL complex and VEGF-R1 in men, and all biomarkers in women, were associated with clinical symptoms of UCPPS. None of the evaluated candidate markers usefully discriminated UCPPS patients from controls. Elevated VEGF, MMP-9 and VEGF-R1 levels in men and VEGF levels in women may provide potential new insights into the pathophysiology of UCPPS. © 2017 The Authors BJU International © 2017 BJU International Published by John Wiley & Sons Ltd.

  8. The impact of body habitus on the surgical outcomes of transaxillary single-incision robotic thyroidectomy in papillary thyroid carcinoma patients.

    PubMed

    Lee, Sohee; Park, Seulkee; Lee, Cho Rok; Son, Haiyoung; Kim, Jungwoo; Kang, Sang-Wook; Jeong, Jong Ju; Nam, Kee-Hyun; Chung, Woong Youn; Park, Cheong Soo

    2013-07-01

    Robotic applications have achieved safe and precise thyroidectomy with notable cosmetic and functional benefits. This study was designed to document the influence of body habitus on robotic thyroidectomy in papillary thyroid carcinoma (PTC) patients. From July 2009 to February 2010, 352 patients underwent robotic thyroidectomy using a gasless, transaxillary single-incision approach at Yonsei University Health System. Body habitus was described using body mass index category (normal weight, overweight, obese), neck length, shoulder width, and shoulder width to neck length ratios. The impact of body habitus on surgical outcomes was analyzed with respect to operation time, number of retrieved central nodes, bleeding amount, and postoperative complications. Of the 352 patients, 217 underwent less than total thyroidectomy and 135 underwent total thyroidectomy. Operative variables (i.e. operation times, bleeding amounts, and numbers of retrieved central nodes) showed no significant differences between three BMI groups for less than total thyroidectomy. However, total operation and working space times were longer for obese patients during total thyroidectomy. In particular, shoulder width was positively correlated with total operation time, working space time, console time, and number of retrieved central nodes. On the other hand, postoperative complications were not significantly different in the three BMI groups and showed no significant correlation with the other indices of body habitus. Standardized robotic thyroidectomy can be performed safely and feasibly in patients with a large body habitus despite longer operation times.

  9. Prognostic significance of electrophysiological tests for facial nerve outcome in vestibular schwannoma surgery.

    PubMed

    van Dinther, J J S; Van Rompaey, V; Somers, T; Zarowski, A; Offeciers, F E

    2011-01-01

    To assess the prognostic significance of pre-operative electrophysiological tests for facial nerve outcome in vestibular schwannoma surgery. Retrospective study design in a tertiary referral neurology unit. We studied a total of 123 patients with unilateral vestibular schwannoma who underwent microsurgical removal of the lesion. Nine patients were excluded because they had clinically abnormal pre-operative facial function. Pre-operative electrophysiological facial nerve function testing (EPhT) was performed. Short-term (1 month) and long-term (1 year) post-operative clinical facial nerve function were assessed. When pre-operative facial nerve function, evaluated by EPhT, was normal, the outcome from clinical follow-up at 1-month post-operatively was excellent in 78% (i.e. HB I-II) of patients, moderate in 11% (i.e. HB III-IV), and bad in 11% (i.e. HB V-VI). After 1 year, 86% had excellent outcomes, 13% had moderate outcomes, and 1% had bad outcomes. Of all patients with normal clinical facial nerve function, 22% had an abnormal EPhT result and 78% had a normal result. No statistically significant differences could be observed in short-term and long-term post-operative facial function between the groups. In this study, electrophysiological tests were not able to predict facial nerve outcome after vestibular schwannoma surgery. Tumour size remains the best pre-operative prognostic indicator of facial nerve function outcome, i.e. a better outcome in smaller lesions.

  10. Development of the Transport Class Model (TCM) Aircraft Simulation From a Sub-Scale Generic Transport Model (GTM) Simulation

    NASA Technical Reports Server (NTRS)

    Hueschen, Richard M.

    2011-01-01

    A six degree-of-freedom, flat-earth dynamics, non-linear, and non-proprietary aircraft simulation was developed that is representative of a generic mid-sized twin-jet transport aircraft. The simulation was developed from a non-proprietary, publicly available, subscale twin-jet transport aircraft simulation using scaling relationships and a modified aerodynamic database. The simulation has an extended aerodynamics database with aero data outside the normal transport-operating envelope (large angle-of-attack and sideslip values). The simulation has representative transport aircraft surface actuator models with variable rate-limits and generally fixed position limits. The simulation contains a generic 40,000 lb sea level thrust engine model. The engine model is a first order dynamic model with a variable time constant that changes according to simulation conditions. The simulation provides a means for interfacing a flight control system to use the simulation sensor variables and to command the surface actuators and throttle position of the engine model.

  11. Grumman WS33 wind system. Phase II: executive summary. Prototype construction and testing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Adler, F M; Hinton, P; King, P W

    1980-11-01

    The configuration of an 8 kW wind turbine generator and its fabrication and pre-delivery testing are discussed. The machine is a three-bladed, down wind turbine designed to interface directly with an electrical utility network. Power is generated in winds between a cut-in speed of 4.0 m/s and a cut-out speed of 22 m/s. A blade pitch control system provides for positioning the rotor at a coarse pitch for start-up, fine pitch for normal running, and a feather position for shut-down. Operation of the machine is controlled by a self-monitoring, programmable logic microprocessor. System components were obtained through a series ofmore » make-buy decisions, tracked and inspected for specification compliance. Only minor modifications from the original design and minor problems of assembly are reported. Four accelerometers were mounted inside the nacelle to determine the accelerations, frequencies and displacements of the system in the three orthogonal axes. A cost analysis is updated. (LEW)« less

  12. The abdominal technetium scan (a decade of experience)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cooney, D.R.; Duszynski, D.O.; Camboa, E.

    1982-10-01

    Out of 270 children with gastrointestinal symptoms, the indications for technetium scanning were: gastrointestinal tract bleeding (165 patients), abdominal pain (99 patients) and a history of intussusception (6 patients). Thirty children had abnormal findings, while the remaining 240 patients had normal scans. Four of the 30 children with positive scans were not explored, while the others underwent laparotomy. Of the 26 operated patients, 12 (46%) had a Meckel's diverticulum. Nine patients (34%) had other pathologic lesions that were detected by the scan. Five had true false positives as no pathologic lesions were found. Of the 240 children with negative scans,more » 19 were eventually explored because of persistent symptoms or clinical findings. Two of these had a Meckel's diverticulum. Eleven had a negative exploration while six had other surgical lesions. Technitium scan should reliably detect around 80%-90% of Meckel's diverticula. It will also accurately exclude the diagnosis of Meckel's diverticulum in over 90% of patients.« less

  13. Fast closing valve

    DOEpatents

    Hanson, Clark L.

    1984-01-10

    A valve is provided for protecting the high vacuum of a particle accelera in the event of air leakage, wherein the valve provides an axially symmetrical passage to avoid disturbance of the partical beam during normal operation, and yet enables very rapid and tight closure of the beam-carrying pipe in the event of air leakage. The valve includes a ball member (30) which can rotate between a first position wherein a bore (32) in the member is aligned with the beam pipe, and a second position out of line with the pipe. A seal member (38) is flexibly sealed to the pipe, and has a seal end which can move tightly against the ball member after the bore has rotated out of line with the pipe, to thereby assure that the seal member does not retard rapid rotation of the ball valve member. The ball valve member can be rapidly rotated by a conductive arm (40) fixed to it and which is rotated by the discharge of a capacitor bank through coils (44, 45) located adjacent to the arm.

  14. [Partial pressure of CO2 and CO2 degassing fluxes of Huayuankou and Xiaolangdi Station affected by Xiaolangdi Reservoir].

    PubMed

    Zhang, Yong-ling; Yang, Xiao-lin; Zhang, Dong

    2015-01-01

    According to periodic sampling analysis per month in Xiaolangdi station and Huayuankou station from November 2011 to October 2012, combined with continuous sampling analysis of Xiaolangdi Reservoir during runoff and sediment control period in 2012, partial pressure of CO2 (pCO2) in surface water were calculated based on Henry's Law, pCO2 features and air-water CO2 degassing fluxes of Huayuankou station and Xiaolangdi station affected by Xiaolangdi Reservoir were studied. The results were listed as follows, when Xiaolangdi Reservoir operated normally, pCO2 in surface water of Xiaolangdi station and Huayuankou station varied from 82 to 195 Pa and from 99 to 228 Pa, moreover, pCO2 in surface water from July to September were distinctly higher than those in other months; meanwhile, pCO, in surface water from Huayuankou station were higher than that from Xiaolangdi station. During runoff and sediment control period of Xiaolangdi Reservoir, two hydrological stations commonly indicated that pCO2 in surface water during water draining were obviously lower than those during sediment releasing. Whether in the period of normal operation or runoff and sediment control, pCO2 in surface water had positive relations to DIC content in two hydrological stations. Since the EpCO,/AOU value was higher than the theoretical value of 0. 62, the biological aerobic respiration effect had distinct contribution to pCO2. Throughout the whole year, air-water CO2 degassing fluxes from Xiaolangdi station and Huayuankou station were 0.486 p.mol (m2 s) -l and 0.588 pmol (m2 x s)(-1) respectively; When Xiaolangdi Reservoir operated normally, air-water CO, degassing fluxes in Huayuankou station were higher than that in Xiaolangdi station; during runoff and sediment control from Xiaolangdi Reservoir, two hydrological stations had one observation result in common, namely, air-water CO2 degassing fluxes in the period of water draining were obviously lower than that in the period of sediment releasing.

  15. 77 FR 66362 - Funding and Fiscal Affairs, Loan Policies and Operations, and Funding Operations; Investment...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-11-05

    ... and Operations, and Funding Operations; Investment Management AGENCY: Farm Credit Administration... cash management operations. Thus, under normal conditions, we expect each Farm Credit bank to manage... investment management and interest rate risk management; reduces regulatory burden for investments that fail...

  16. Waist-to-hip ratio is better at predicting subclinical atherosclerosis than body mass index and waist circumference in postmenopausal women.

    PubMed

    Lee, Hyun Jung; Hwang, Soon Young; Hong, Ho Cheol; Ryu, Ja Young; Seo, Ji A; Kim, Sin Gon; Kim, Nan Hee; Choi, Dong Seop; Baik, Sei Hyun; Choi, Kyung Mook; Yoo, Hye Jin

    2015-03-01

    Body fat distribution becomes more central after menopause. Although some studies have identified the superiority of various anthropometric indices to assess general health outcomes, very limited studies have compared the efficacy of body mass index (BMI), waist circumference (WC), and waist-to-hip ratio (WHR) to predict subclinical atherosclerosis according to menopausal status. In total, 442 participants (209 premenopausal women and 233 postmenopausal women) were prospectively enrolled from the Health Promotion Center of Korea University Guro Hospital. We examined subclinical atherosclerosis using carotid intima-media thickness (CIMT) and brachial-ankle pulse wave velocity (baPWV). In premenopausal women, all anthropometric parameters such as BMI, WC and WHR were positively correlated with baPWV and CIMT values, whereas in postmenopausal women, only WHR was positively correlated with baPWV values (0.27, P<0.01), and WC and WHR were positively correlated with CIMT (0.15, P<0.05 and 0.21, P<0.01, respectively). By receiver operating characteristic (ROC) curve analyses, WHR was superior to the other anthropometric indices to predict carotid atherosclerosis in postmenopausal women. Furthermore, the normal weight (BMI<23kg/m(2)) with higher WHR group had a significantly thicker CIMT when compared to the normal weight with lower WHR group (0.76mm vs. 0.68mm, P<0.01) and even the overweight subjects with BMI≥23kg/m(2) (0.76mm vs. 0.70mm, P<0.01) in postmenopausal women. The present study shows that WHR has the best potential for predicting subclinical atherosclerosis compared to BMI and WC in postmenopausal women. NCT01594710. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  17. Electrification in winter storms and the analysis of thunderstorm overflight

    NASA Technical Reports Server (NTRS)

    Brook, Marx

    1991-01-01

    The emergence of 24 hr operational lightning detection networks has led to the finding that positive lightning strokes, although still much fewer in number than the normal negative strokes, are present in summer and winter storms. Recent papers address the importance of understanding the meteorological conditions which lead to a dominance of one polarity of stroke over another; the appearance of positive strokes at the end of a storm appeared to presage the end-of-storm downdraft and subsidence leading to downburst activity. It is beginning to appear that positive strokes may be important meteorological indicators. Significant research accomplishments on the following topics are addressed: (1) a study to verify that the black boxes used in the lightning networks to detect both negative and positive strokes to ground were accurate; (2) the use of slow tails to determine the polarity of distant lightning; (3) lightning initiation in winter vs. summer storms; (4) the upgrade of sensors for the measurement of electric field signals associated with lightning; (5) the analysis of lightning flash records from storms between 40 and 125 km from the sensor; and (6) an interesting aspect of the initiation process which involves the physical processes driving the stepped leader. The focus of current research and future research plans are presented.

  18. Perceived discrimination among men and women with normal weight and obesity. A population-based study from Sweden.

    PubMed

    Hansson, Lena M; Näslund, Erik; Rasmussen, Finn

    2010-08-01

    We examined whether men and women with obesity reported different types of discrimination to a greater extent than those with normal weight, and explored whether these associations were modified by socioeconomic position. National representative sample of men and women, with normal weight (n = 2,000), moderate obesity (n = 2,461) and severe obesity (n = 557). Participants were identified in a yearly population-based survey (1996-2006) and data on perceived discrimination and potential confounding factors were measured in 2008. Logistic regression models tested whether obesity was associated with perceived lifetime, workplace, healthcare and interpersonal discrimination. The overall response rate was 56%. For men, moderate obesity was associated with workplace discrimination, while severely obese women were more likely to report this sort of discrimination than normal weight women. Severely obese individuals were twice as likely to report healthcare discrimination than normal weight individuals. Women, regardless of weight status group, were in turn twice as likely to report healthcare discrimination as men. Women with severe obesity were significantly more likely to report interpersonal discrimination compared with normal weight women. Socioeconomic position modified the association between weight status and healthcare discrimination. Highly educated individuals with moderate and severe obesity were more likely to report healthcare discrimination than their normal weight counterparts, whereas low educated individuals with normal weight, moderate and severe obesity were equally likely to report discrimination. In this large, population-based study, discrimination was more likely to be reported by obese individuals compared with those of normal weight. The associations, however, varied according to gender and socioeconomic position.

  19. Statistical analysis of the 70 meter antenna surface distortions

    NASA Technical Reports Server (NTRS)

    Kiedron, K.; Chian, C. T.; Chuang, K. L.

    1987-01-01

    Statistical analysis of surface distortions of the 70 meter NASA/JPL antenna, located at Goldstone, was performed. The purpose of this analysis is to verify whether deviations due to gravity loading can be treated as quasi-random variables with normal distribution. Histograms of the RF pathlength error distribution for several antenna elevation positions were generated. The results indicate that the deviations from the ideal antenna surface are not normally distributed. The observed density distribution for all antenna elevation angles is taller and narrower than the normal density, which results in large positive values of kurtosis and a significant amount of skewness. The skewness of the distribution changes from positive to negative as the antenna elevation changes from zenith to horizon.

  20. Investigation of 2.1-micron lasing properties of Ho:Tm:Cr:YAG crystals under flash-lamp pumping at various operating conditions

    NASA Technical Reports Server (NTRS)

    Kim, Kyong H.; Choi, Young S.; Barnes, Norman P.; Hess, Robert V.; Bair, Clayton H.; Brockman, Philip

    1993-01-01

    Flash-lamp-pumped normal-mode and Q-switched 2.1-micron laser operations of Ho:Tm:Cr:YAG crystals have been evaluated under a wide variety of experimental conditions in order to determine an optimum lasing condition and to characterize the laser outputs. Q-switched laser-output energies equal to, or in some cases exceeding the normal-mode laser energies, were obtained in the form of a strong single spike through an optimization of the opening time of a lithium niobate Q switch. The increase of the normal-mode laser slope efficiency was observed with the increase of the Tm concentration from 2.5 to 4.5 at. pct at operating temperatures from 120 K to near room temperature. Laser transitions were observed only at 2.098 and 2.091 microns under various conditions. The 2.091-micron laser transition appeared to be dominant at high-temperature operations with low-reflective-output couplers.

  1. Comparison of normalization methods for the analysis of metagenomic gene abundance data.

    PubMed

    Pereira, Mariana Buongermino; Wallroth, Mikael; Jonsson, Viktor; Kristiansson, Erik

    2018-04-20

    In shotgun metagenomics, microbial communities are studied through direct sequencing of DNA without any prior cultivation. By comparing gene abundances estimated from the generated sequencing reads, functional differences between the communities can be identified. However, gene abundance data is affected by high levels of systematic variability, which can greatly reduce the statistical power and introduce false positives. Normalization, which is the process where systematic variability is identified and removed, is therefore a vital part of the data analysis. A wide range of normalization methods for high-dimensional count data has been proposed but their performance on the analysis of shotgun metagenomic data has not been evaluated. Here, we present a systematic evaluation of nine normalization methods for gene abundance data. The methods were evaluated through resampling of three comprehensive datasets, creating a realistic setting that preserved the unique characteristics of metagenomic data. Performance was measured in terms of the methods ability to identify differentially abundant genes (DAGs), correctly calculate unbiased p-values and control the false discovery rate (FDR). Our results showed that the choice of normalization method has a large impact on the end results. When the DAGs were asymmetrically present between the experimental conditions, many normalization methods had a reduced true positive rate (TPR) and a high false positive rate (FPR). The methods trimmed mean of M-values (TMM) and relative log expression (RLE) had the overall highest performance and are therefore recommended for the analysis of gene abundance data. For larger sample sizes, CSS also showed satisfactory performance. This study emphasizes the importance of selecting a suitable normalization methods in the analysis of data from shotgun metagenomics. Our results also demonstrate that improper methods may result in unacceptably high levels of false positives, which in turn may lead to incorrect or obfuscated biological interpretation.

  2. Structural fabrication quality as a factor of industrial facilities safety

    NASA Astrophysics Data System (ADS)

    Tishkov, E. V.; Kardaev, E. M.; Stolbova, S. Yu; Shishova, O. S.

    2018-04-01

    In the conditions of industrial facilities high wear degree, it is very important to ensure the possibility of their safe operation in order to avoid various kinds of accidents and catastrophes. As practice shows, industrial plant collapses can occur suddenly under normal operating conditions. Usually, such accidents can take place at different stages of structures life cycle. One of the reasons for this is the initially low quality of reinforced concrete structures fabrication. The article considers the factors contributing to the collapse of reinforced concrete structures of water purification tanks located on the territory of the Omsk Region. The main surveys results on tank structures after collapse with the use of ultrasonic and physical methods of investigation are presented. On the basis of the obtained data analysis, it was found that the main cause of the accidents was the insufficient load-bearing capacity of typical reinforced concrete structures, caused by defects in their fabrication in the factory conditions because of exceeding the standard displacement from the design position of the working reinforcement. Recommendations are given on the identification of defective structures and the prevention of similar accidents when operating similar tanks at manufacturing plants constructed from standard designs.

  3. Dynamic analysis and numerical experiments for balancing of the continuous single-disc and single-span rotor-bearing system

    NASA Astrophysics Data System (ADS)

    Wang, Aiming; Cheng, Xiaohan; Meng, Guoying; Xia, Yun; Wo, Lei; Wang, Ziyi

    2017-03-01

    Identification of rotor unbalance is critical for normal operation of rotating machinery. The single-disc and single-span rotor, as the most fundamental rotor-bearing system, has attracted research attention over a long time. In this paper, the continuous single-disc and single-span rotor is modeled as a homogeneous and elastic Euler-Bernoulli beam, and the forces applied by bearings and disc on the shaft are considered as point forces. A fourth-order non-homogeneous partial differential equation set with homogeneous boundary condition is solved for analytical solution, which expresses the unbalance response as a function of position, rotor unbalance and the stiffness and damping coefficients of bearings. Based on this analytical method, a novel Measurement Point Vector Method (MPVM) is proposed to identify rotor unbalance while operating. Only a measured unbalance response registered for four selected cross-sections of the rotor-shaft under steady-state operating conditions is needed when using the method. Numerical simulation shows that the detection error of the proposed method is very small when measurement error is negligible. The proposed method provides an efficient way for rotor balancing without test runs and external excitations.

  4. A PC-based high temperature gas reactor simulator for Indonesian conceptual HTR reactor basic training

    NASA Astrophysics Data System (ADS)

    Syarip; Po, L. C. C.

    2018-05-01

    In planning for nuclear power plant construction in Indonesia, helium cooled high temperature reactor (HTR) is favorable for not relying upon water supply that might be interrupted by earthquake. In order to train its personnel, BATAN has cooperated with Micro-Simulation Technology of USA to develop a 200 MWt PC-based simulation model PCTRAN/HTR. It operates in Win10 environment with graphic user interface (GUI). Normal operation of startup, power maneuvering, shutdown and accidents including pipe breaks and complete loss of AC power have been conducted. A sample case of safety analysis simulation to demonstrate the inherent safety features of HTR was done for helium pipe break malfunction scenario. The analysis was done for the variation of primary coolant pipe break i.e. from 0,1% - 0,5 % and 1% - 10 % helium gas leakages, while the reactor was operated at the maximum constant power of 10 MWt. The result shows that the highest temperature of HTR fuel centerline and coolant were 1150 °C and 1296 °C respectively. With 10 kg/s of helium flow in the reactor core, the thermal power will back to the startup position after 1287 s of helium pipe break malfunction.

  5. Lessons Learned from Pit Viper System Deployment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Catalan, Michael A.; Alzheimer, James M.; Valdez, Patrick LJ

    2002-04-11

    Tele-operated and robotic systems operated in unstructured field environments pose unique challenges for tool design. Since field tasks are not always well defined and the robot work area usually cannot be designed for ease of operation, the tools must be versatile. It's important to carefully consider the orientation of the grip the robot takes on the tool, as it's not easily changed in the field. The stiffness of the robot and the possibility of robot positioning errors encourages the use of non-contact or minimal-contact tooling. While normal hand tools can usually be modified for use by the robot, this ismore » not always the most effective approach. It's desirable to have tooling that is relatively independent of the robot; in this case, the robot places the tool near the desired work location and the tool performs its task relatively independently. Here we consider the adaptation of a number of tools for cleanup of a radioactively contaminated piping junction and valve pit. The tasks to be considered are debris removal (small nuts and bolts and pipe up to 100 mm in diameter), size reduction, surface cleaning, and support of past practice crane-based methods for working in the pits.« less

  6. TransFormers for Ensuring Long-Term Operations in Lunar Extreme Environments

    NASA Technical Reports Server (NTRS)

    Mantovani, J. G.; Stoica, A.; Alkalai, L.; Wilcox, B.; Quadrelli, M.

    2016-01-01

    "Surviving Extreme Space Environments" (EE) is one of NASA's Space Technology Grand Challenges. Power generation and thermal control are the key survival ingredients that allow a robotic explorer to cope with the EE using resources available to it, for example, by harvesting the local solar energy or by utilizing an onboard radioisotope thermoelectric generator (RTG). TransFormers (TFs) are a new technology concept designed to transform a localized area within a harsh extreme environment into a survivable micro-environment by projecting energy to the precise location where robots or humans operate. For example, TFs placed at a location on the rim of Shackleton Crater, which is illuminated by solar radiation for most of the year, would be able to reflect solar energy onto robots operating in the dark cold crater. TFs utilize a shape transformation mechanism to un-fold from a compact volume to a large reflective surface, and to control how much-and where-the energy is projected, and by adjusting for the changing position of the sun. TFs would enable in-situ resource utilization (ISRU) activities within locations of high interest that would normally be unreachable because of their extreme environment

  7. In-SITU, Time-resolved Raman Spectro-micro-topography of an Operating Lithium Ion Battery

    NASA Technical Reports Server (NTRS)

    Luo, Yu; Cai, Wen-Bin; Xing, Xue-Kun; Scherson, Daniel A.

    2003-01-01

    A Raman microscope has been coupled to a computer-controlled, two-dimensional linear translator attached to a custom-designed, sealed optical chamber to allow in situ acquisition of space-, and time-resolved spectra of an operating thin graphite/LiCoO2 Li-ion battery. This unique arrangement made it possible to collect continuously series of Raman spectra from a sharply defined edge of the battery exposing the anode (A), separator (S), and cathode (C), during charge and discharge, while the device was moved back and forth under the fixed focused laser beam along an axis normal to the layered A/S/C plane. Clear spectral evidence was obtained for changes in the amount of Li(+) within particles of graphite in the anode, and, to a lesser extent, of LiCoO2 in the cathode, during battery discharge both as a function of position and time. Analysis of time-resolved Raman spectro-micro-topography (SMT) measurements of the type described in this work are expected to open new prospects for assessing the validity of theoretical models aimed at simulating the flow of Li(+) within Li-ion batteries under operating conditions.

  8. Health hazard evaluation report HETA 85-538-1667, General Telephone Company, Sherman, Texas

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pettigrew, G.L.

    1986-02-01

    Following an employee request, potential health problems among telephone cable splicers were investigated at the General Telephone Company Sherman, Texas. Information was collected on materials used, work procedures, and personal protective equipment employed. Materials of primary concern were petrolatum in the filled cable, petroleum distillates used as cable cleaner, and isocyanates in the two-part reenterable encapsulant. Personal air samples taken by OSHA during pouring operations with the encapsulant revealed no detectable isocyanate concentrations. Observation of a large splicing operation showed the head of the splicer was positioned over the top of the casing while pouring encapsulant components allowing potential exposure.more » Petrolatum was determined to be physiologically inert. Nine of 32 potentially exposed workers completed questionnaires. The most frequently reported symptoms were head congestion and headaches at work; 67% reported warts and 33% reported skin rashes. The author concludes that a health hazard to employees does not exist under normal operating conditions. Workers are advised not to use cable cleaner for personal cleanup. To avoid potential isocyanate sensitization, minimizing exposure, use of personal protective equipment, and good work practices are recommended. Cuts and abrasions among splicers may be implicated in wart formation.« less

  9. A Spiking Strategy for ChIP-chip Data Normalization in S. cerevisiae.

    PubMed

    Jeronimo, Célia; Robert, François

    2017-01-01

    Chromatin immunoprecipitation coupled to DNA microarrays (ChIP-chip) is widely used in the chromatin field, notably to map the position of histone variants or histone modifications along the genome. Often, the position and the occupancy of these epigenetic marks are to be compared between different experiments. It is now increasingly recognized that such cross-sample comparison is better done using externally added exogenous controls for normalization but no such method has been described for ChIP-chip. Here we describe a spiking normalization strategy that makes use of phiX174 phage DNA as a spiked control for normalization of ChIP-chip signals across different experiments.

  10. Analysis of the dynamic response of a supersonic inlet to flow-field perturbations upstream of the normal shock

    NASA Technical Reports Server (NTRS)

    Cole, G. L.; Willoh, R. G.

    1975-01-01

    A linearized mathematical analysis is presented for determining the response of normal shock position and subsonic duct pressures to flow-field perturbations upstream of the normal shock in mixed-compression supersonic inlets. The inlet duct cross-sectional area variation is approximated by constant-area sections; this approximation results in one-dimensional wave equations. A movable normal shock separates the supersonic and subsonic flow regions, and a choked exit is assumed for the inlet exit condition. The analysis leads to a closed-form matrix solution for the shock position and pressure transfer functions. Analytical frequency response results are compared with experimental data and a method of characteristics solution.

  11. CFD simulation of MSW combustion and SNCR in a commercial incinerator

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xia, Zihong; Li, Jian; Wu, Tingting

    Highlights: • Presented a CFD scheme for modeling MSW incinerator including SNCR process. • Performed a sensitivity analysis of SNCR operating conditions. • Non-uniform distributions of gas velocity, temperature and NO{sub x} in the incinerator. • The injection position of reagent was critical for a desirable performance of SNCR. • A NSR 1.5 was recommended as a compromise of NO{sub x} reduction rates and NH{sub 3} slip. - Abstract: A CFD scheme was presented for modeling municipal solid waste (MSW) combustion in a moving-grate incinerator, including the in-bed burning of solid wastes, the out-of-bed burnout of gaseous volatiles, and themore » selective non-catalytic reduction (SNCR) process between urea (CO(NH{sub 2}){sub 2}) and NO{sub x}. The in-bed calculations provided 2-D profiles of the gas–solid temperatures and the gas species concentrations along the bed length, which were then used as inlet conditions for the out-of-bed computations. The over-bed simulations provided the profiles of incident radiation heat flux on the top of bed. A 3-dimensional benchmark simulation was conducted with a 750 t/day commercial incinerator using the present coupling scheme incorporating with a reduced SNCR reduction mechanism. Numerical tests were performed to investigate the effects of operating parameters such as injection position, injection speed and the normalized stoichiometric ratio (NSR) on the SNCR performance. The simulation results showed that the distributions of gas velocity, temperature and NO{sub x} concentration were highly non-uniform, which made the injection position one of the most sensitive operating parameters influencing the SNCR performance of moving grate incinerators. The simulation results also showed that multi-layer injections were needed to meet the EU2000 standard, and a NSR 1.5 was suggested as a compromise of a satisfactory NO{sub x} reduction and reasonable NH{sub 3} slip rates. This work provided useful guides to the design and operation of SNCR process in moving-grate incinerators.« less

  12. Anatomical frame identification and reconstruction for repeatable lower limb joint kinematics estimates.

    PubMed

    Donati, Marco; Camomilla, Valentina; Vannozzi, Giuseppe; Cappozzo, Aurelio

    2008-07-19

    The quantitative description of joint mechanics during movement requires the reconstruction of the position and orientation of selected anatomical axes with respect to a laboratory reference frame. These anatomical axes are identified through an ad hoc anatomical calibration procedure and their position and orientation are reconstructed relative to bone-embedded frames normally derived from photogrammetric marker positions and used to describe movement. The repeatability of anatomical calibration, both within and between subjects, is crucial for kinematic and kinetic end results. This paper illustrates an anatomical calibration approach, which does not require anatomical landmark manual palpation, described in the literature to be prone to great indeterminacy. This approach allows for the estimate of subject-specific bone morphology and automatic anatomical frame identification. The experimental procedure consists of digitization through photogrammetry of superficial points selected over the areas of the bone covered with a thin layer of soft tissue. Information concerning the location of internal anatomical landmarks, such as a joint center obtained using a functional approach, may also be added. The data thus acquired are matched with the digital model of a deformable template bone. Consequently, the repeatability of pelvis, knee and hip joint angles is determined. Five volunteers, each of whom performed five walking trials, and six operators, with no specific knowledge of anatomy, participated in the study. Descriptive statistics analysis was performed during upright posture, showing a limited dispersion of all angles (less than 3 deg) except for hip and knee internal-external rotation (6 deg and 9 deg, respectively). During level walking, the ratio of inter-operator and inter-trial error and an absolute subject-specific repeatability were assessed. For pelvic and hip angles, and knee flexion-extension the inter-operator error was equal to the inter-trial error-the absolute error ranging from 0.1 deg to 0.9 deg. Knee internal-external rotation and ab-adduction showed, on average, inter-operator errors, which were 8% and 28% greater than the relevant inter-trial errors, respectively. The absolute error was in the range 0.9-2.9 deg.

  13. Comparison of noncontact infrared and remote sensor thermometry in normal and dry eye patients.

    PubMed

    Singh, G; Singh Bhinder, H

    To evaluate the role of closed chamber infrared and remote sensor thermometry in normal and dry eye patients. The study was conducted on 51 dry eye cases (102 eyes), 26 men and 25 women aged 19 to 65 years (35.3614.36), and 51 normal (102 eyes) age- and sex-matched control subjects. The criteria for dry eye were Schirm e r-1 (<10 m/5 min), FTBUT (<10 sec), nd lissamine green score (>2). The remote sensor and infrared thermometry was done in losed chamber around the eye in closed and open eye positions. In normal eyes, closed chamber infrared thermometry recorded temperature 34.770.37 C in closed eye position and 35.020.39 C in open eye position as compared to 27.912.46 C in closed eye position and 28.012.46 C in open position with remote sensor thermometry. The difference in temperature from closed to open position was 0.250.90 C in infrared thermometry and 0.100.00 C with remote sensor thermometry, which was statistically significant (p<0.0000). In dry eye, the infrared therm o m e t ry recorded 35.080.61 C temperature in closed eye position and 35.530.63 C in open eye position as compared to 27.412.48 C in open and closed eye position with remote sensor thermometry. The difference in temperature from closed to open eye position was 0.450.14 C (p<0.0000) with infrared thermometry as compared to no change 0.000.00 C with remote sensor thermometry (p<0.0000). Remote sensor thermometry proved better for diagnosis of dry eye disease as it showed no change in temperature under closed chamber in closed and open position (p=0.0000). Infrared thermometry was better in recording the absolute temperature from any point on the eye.

  14. Comparison of noncontact infrared and remote sensor thermometry in normal and dry eye patients.

    PubMed

    Singh, G; Bhinder, H Singh

    2005-01-01

    To evaluate the role of closed chamber infrared and remote sensor thermometry in normal and dry eye patients. The study was conducted on 51 dry eye cases (102 eyes), 26 men and 25 women aged 19 to 65 years (35.36+/-14.36), and 51 normal (102 eyes) age- and sex-matched control subjects. The criteria for dry eye were Schirmer-1 (<10 m/5 min), FTBUT (<10 sec), nd lissamine green score (>2). The remote sensor and infrared thermometry was done in closed chamber around the eye in closed and open eye positions. In normal eyes, closed chamber infrared thermometry recorded temperature 34.77+/-0.37 degrees C in closed eye position and 35.02+/-0.39 degrees C in open eye position as compared to 27.91+/-2.46 degrees C in closed eye position and 28.01+/-2.46 degrees C in open position with remote sensor thermometry. The difference in temperature from closed to open position was 0.25+/-0.90 degrees C in infrared thermometry and 0.10+/-0.00 degrees C with remote sensor thermometry, which was statistically significant (p<0.0000). In dry eye, the infrared thermometry recorded 35.08+/-0.61 degrees C temperature in closed eye position and 35.53+/-0.63 degrees C in open eye position as compared to 27.41+/-2.48 degrees C in open and closed eye position with remote sensor thermometry. The difference in temperature from closed to open eye position was 0.45+/-0.14 degrees C (p<0.0000) with infrared thermometry as compared to no change 0.00+/-0.00 degrees C with remote sensor thermometry (p<0.0000). Remote sensor thermometry proved better for diagnosis of dry eye disease as it showed no change in temperature under closed chamber in closed and open position (p=0.0000). Infrared thermometry was better in recording the absolute temperature from any point on the eye.

  15. A General Theory of Unsteady Compressible Potential Aerodynamics

    NASA Technical Reports Server (NTRS)

    Morino, L.

    1974-01-01

    The general theory of potential aerodynamic flow around a lifting body having arbitrary shape and motion is presented. By using the Green function method, an integral representation for the potential is obtained for both supersonic and subsonic flow. Under small perturbation assumption, the potential at any point, P, in the field depends only upon the values of the potential and its normal derivative on the surface, sigma, of the body. Hence, if the point P approaches the surface of the body, the representation reduces to an integro-differential equation relating the potential and its normal derivative (which is known from the boundary conditions) on the surface sigma. For the important practical case of small harmonic oscillation around a rest position, the equation reduces to a two-dimensional Fredholm integral equation of second-type. It is shown that this equation reduces properly to the lifting surface theories as well as other classical mathematical formulas. The question of uniqueness is examined and it is shown that, for thin wings, the operator becomes singular as the thickness approaches zero. This fact may yield numerical problems for very thin wings.

  16. Radiance, polarization, and ellipticity of the radiation in the earth's atmosphere

    NASA Technical Reports Server (NTRS)

    Hitzfelder, S. J.; Plass, G. N.; Kattawar, G. W.

    1976-01-01

    The complete radiation field including polarization is calculated for a model of the real atmosphere by the matrix operator method. The radiance, direction and amount of polarization, and ellipticity are obtained at the top and bottom of the atmosphere for three values of the surface albedo (0; 0.15 0.90) and five solar zenith angles. Scattering and absorption by molecules (including ozone) and by aerosols are taken into account together with the variation of the number density of these substances with height. All results are calculated for both a normal aerosol number and a distribution which is one-third of the normal amount at all heights. The calculated values show general qualitative agreement with the available experimental measurements. The position of the neutral points of the polarization in the principal plane is a sensitive indicator of the characteristics of the aerosol particles in the atmosphere, since it depends on the sign and value of the single scattered polarization for scattering angles around 20 deg and 160 deg for transmitted and reflected photons respectively.

  17. Aggregation of Electric Current Consumption Features to Extract Maintenance KPIs

    NASA Astrophysics Data System (ADS)

    Simon, Victor; Johansson, Carl-Anders; Galar, Diego

    2017-09-01

    All electric powered machines offer the possibility of extracting information and calculating Key Performance Indicators (KPIs) from the electric current signal. Depending on the time window, sampling frequency and type of analysis, different indicators from the micro to macro level can be calculated for such aspects as maintenance, production, energy consumption etc. On the micro-level, the indicators are generally used for condition monitoring and diagnostics and are normally based on a short time window and a high sampling frequency. The macro indicators are normally based on a longer time window with a slower sampling frequency and are used as indicators for overall performance, cost or consumption. The indicators can be calculated directly from the current signal but can also be based on a combination of information from the current signal and operational data like rpm, position etc. One or several of those indicators can be used for prediction and prognostics of a machine's future behavior. This paper uses this technique to calculate indicators for maintenance and energy optimization in electric powered machines and fleets of machines, especially machine tools.

  18. Polymer thick-film conductors and dielectrics for membrane switches and flexible circuitry

    NASA Technical Reports Server (NTRS)

    Nazarenko, N.

    1983-01-01

    The fabrication and operation of membrane switches are discussed. The membrane switch functions as a normally open, momentary contact, low-voltage pressure-sensitive device. Its design is a three-layer sandwich usually constructed of polyester film. Conductive patterns are deposited onto the inner side of top and bottom sheets by silk screening. The center spacer is then placed between the two circuit layers to form a sandwich, generally held together by an adhesive. When pressure is applied to the top layer, it flexes through the punched openings of the spacer to establish electrical contact between conductive pads of the upper and lower sheets, momentarily closing the circuit. Upon release of force the top sheet springs back to its normal open position. The membrane touch switch is being used in a rapidly expanding range of applications, including instrumentation, appliances, electronic games and keyboards. Its board acceptance results from its low cost, durability, ease of manufacture, cosmetic appeal and design flexibility. The principal electronic components in the membrane switch are the conductor and dielectric.

  19. Fault diagnosis of sensor networked structures with multiple faults using a virtual beam based approach

    NASA Astrophysics Data System (ADS)

    Wang, H.; Jing, X. J.

    2017-07-01

    This paper presents a virtual beam based approach suitable for conducting diagnosis of multiple faults in complex structures with limited prior knowledge of the faults involved. The "virtual beam", a recently-proposed concept for fault detection in complex structures, is applied, which consists of a chain of sensors representing a vibration energy transmission path embedded in the complex structure. Statistical tests and adaptive threshold are particularly adopted for fault detection due to limited prior knowledge of normal operational conditions and fault conditions. To isolate the multiple faults within a specific structure or substructure of a more complex one, a 'biased running' strategy is developed and embedded within the bacterial-based optimization method to construct effective virtual beams and thus to improve the accuracy of localization. The proposed method is easy and efficient to implement for multiple fault localization with limited prior knowledge of normal conditions and faults. With extensive experimental results, it is validated that the proposed method can localize both single fault and multiple faults more effectively than the classical trust index subtract on negative add on positive (TI-SNAP) method.

  20. 14 CFR 27.683 - Operation tests.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Operation tests. 27.683 Section 27.683... STANDARDS: NORMAL CATEGORY ROTORCRAFT Design and Construction Control Systems § 27.683 Operation tests. It must be shown by operation tests that, when the controls are operated from the pilot compartment with...

  1. 14 CFR 27.683 - Operation tests.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Operation tests. 27.683 Section 27.683... STANDARDS: NORMAL CATEGORY ROTORCRAFT Design and Construction Control Systems § 27.683 Operation tests. It must be shown by operation tests that, when the controls are operated from the pilot compartment with...

  2. The Role of Polymerase Chain Reaction of High-Risk Human Papilloma Virus in the Screening of High-Grade Squamous Intraepithelial Lesions in the Anal Mucosa of Human Immunodeficiency Virus-Positive Males Having Sex with Males

    PubMed Central

    Hidalgo-Tenorio, Carmen; Rivero-Rodriguez, Mar; Gil-Anguita, Concepción; Esquivias, Javier; López-Castro, Rodrigo; Ramírez-Taboada, Jessica; de Hierro, Mercedes López; López-Ruiz, Miguel A.; Martínez, R. Javier; Llaño, Juan P.

    2015-01-01

    Objectives To evaluate the advantages of cytology and PCR of high-risk human papilloma virus (PCR HR-HPV) infection in biopsy-derived diagnosis of high-grade squamous intraepithelial lesions (HSIL = AIN2/AIN3) in HIV-positive men having sex with men (MSM). Methods This is a single-centered study conducted between May 2010 and May 2014 in patients (n = 201, mean age 37 years) recruited from our outpatient clinic. Samples of anal canal mucosa were taken into liquid medium for PCR HPV analysis and for cytology. Anoscopy was performed for histology evaluation. Results Anoscopy showed 33.8% were normal, 47.8% low-grade squamous intraepithelial lesions (LSIL), and 18.4% HSIL; 80.2% had HR-HPV. PCR of HR-HPV had greater sensitivity than did cytology (88.8% vs. 75.7%) in HSIL screening, with similar positive (PPV) and negative predictive value (NPV) of 20.3 vs. 22.9 and 89.7 vs. 88.1, respectively. Combining both tests increased the sensitivity and NPV of HSIL diagnosis to 100%. Correlation of cytology vs. histology was, generally, very low and PCR of HR-HPV vs. histology was non-existent (<0.2) or low (<0.4). Area under the receiver operating characteristics (AUROC) curve analysis of cytology and PCR HR-HPV for the diagnosis of HSIL was poor (<0.6). Multivariate regression analysis showed protective factors against HSIL were: viral suppression (OR: 0.312; 95%CI: 0.099-0.984), and/or syphilis infection (OR: 0.193; 95%CI: 0.045-0.827). HSIL risk was associated with HPV-68 genotype (OR: 20.1; 95%CI: 2.04-197.82). Conclusions When cytology and PCR HR-HPV findings are normal, the diagnosis of pre-malignant HSIL can be reliably ruled-out in HIV-positive patients. HPV suppression with treatment protects against the appearance of HSIL. PMID:25849412

  3. High-risk human papillomavirus (hrHPV) E6/E7 mRNA testing by PreTect HPV-Proofer for detection of cervical high-grade intraepithelial neoplasia and cancer among hrHPV DNA-positive women with normal cytology.

    PubMed

    Rijkaart, D C; Heideman, D A M; Coupe, V M H; Brink, A A T P; Verheijen, R H M; Skomedal, H; Karlsen, F; Morland, E; Snijders, P J F; Meijer, C J L M

    2012-07-01

    Our aim was to investigate whether high-risk HPV (hrHPV) mRNA detection by PreTect HPV-Proofer can be used to stratify hrHPV DNA-positive women of different cytology classes for risk of high-grade cervical intraepithelial neoplasia or worse (cervical precancer or cancer, i.e., cervical intraepithelial neoplasia grade 2 or higher [≥ CIN2]). A total of 375 women participating in population-based screening, with a GP5+/6+-PCR hrHPV DNA-positive cervical scrape with normal cytology (n = 202), borderline or mild dyskaryosis (BMD) (n = 88), or moderate dyskaryosis or worse (>BMD) (n = 85), were enrolled. Cervical scrapes were additionally subjected to HPV16/18/31/33/45 E6/E7 mRNA analysis by PreTect HPV-Proofer (mRNA test). Referral and follow-up policies were based on cytology, hrHPV DNA, and mRNA testing. The primary study endpoint was the number of ≥CIN2 detected within 3 years of follow-up. The mRNA positivity increased with the severity of cytological abnormality, ranging from 32% (64/202) in hrHPV DNA-positive women with normal cytology to 47% (41/88) in BMD and 68% (58/85) in >BMD groups (P < 0.01). Women with ≥ CIN2 were more likely to test positive by mRNA test (63%) than women without evidence of ≥ CIN2 (32%; P < 0.01). A positive mRNA test result conferred an increased ≥ CIN2 risk in hrHPV DNA-positive women with normal cytology, i.e., 0.55 (95% confidence interval [95% CI], 0.34 to 0.76) in mRNA-positive versus 0.20 (95% CI, 0.07 to 0.33) in mRNA-negative women. In hrHPV DNA-positive women with BMD or >BMD, the result of the mRNA test did not influence the ≥ CIN2 risk. In conclusion, mRNA testing by PreTect HPV-Proofer might be of value to select hrHPV DNA-positive women with normal cytology in need of immediate referral for colposcopy.

  4. High-Risk Human Papillomavirus (hrHPV) E6/E7 mRNA Testing by PreTect HPV-Proofer for Detection of Cervical High-Grade Intraepithelial Neoplasia and Cancer among hrHPV DNA-Positive Women with Normal Cytology

    PubMed Central

    Rijkaart, D. C.; Heideman, D. A. M.; Coupe, V. M. H.; Brink, A. A. T. P.; Verheijen, R. H. M.; Skomedal, H.; Karlsen, F.; Morland, E.; Snijders, P. J. F.

    2012-01-01

    Our aim was to investigate whether high-risk HPV (hrHPV) mRNA detection by PreTect HPV-Proofer can be used to stratify hrHPV DNA-positive women of different cytology classes for risk of high-grade cervical intraepithelial neoplasia or worse (cervical precancer or cancer, i.e., cervical intraepithelial neoplasia grade 2 or higher [≥CIN2]). A total of 375 women participating in population-based screening, with a GP5+/6+-PCR hrHPV DNA-positive cervical scrape with normal cytology (n = 202), borderline or mild dyskaryosis (BMD) (n = 88), or moderate dyskaryosis or worse (>BMD) (n = 85), were enrolled. Cervical scrapes were additionally subjected to HPV16/18/31/33/45 E6/E7 mRNA analysis by PreTect HPV-Proofer (mRNA test). Referral and follow-up policies were based on cytology, hrHPV DNA, and mRNA testing. The primary study endpoint was the number of ≥CIN2 detected within 3 years of follow-up. The mRNA positivity increased with the severity of cytological abnormality, ranging from 32% (64/202) in hrHPV DNA-positive women with normal cytology to 47% (41/88) in BMD and 68% (58/85) in >BMD groups (P < 0.01). Women with ≥CIN2 were more likely to test positive by mRNA test (63%) than women without evidence of ≥CIN2 (32%; P < 0.01). A positive mRNA test result conferred an increased ≥CIN2 risk in hrHPV DNA-positive women with normal cytology, i.e., 0.55 (95% confidence interval [95% CI], 0.34 to 0.76) in mRNA-positive versus 0.20 (95% CI, 0.07 to 0.33) in mRNA-negative women. In hrHPV DNA-positive women with BMD or >BMD, the result of the mRNA test did not influence the ≥CIN2 risk. In conclusion, mRNA testing by PreTect HPV-Proofer might be of value to select hrHPV DNA-positive women with normal cytology in need of immediate referral for colposcopy. PMID:22553244

  5. Infiltration with lidocaine and adrenaline instead of normal saline does not improve the septoplasty procedure.

    PubMed

    Gungor, Volkan; Baklaci, Deniz; Kum, Rauf Oguzhan; Yilmaz, Yavuz Fuat; Ozcan, Muge; Unal, Adnan

    2016-08-01

    The aim of this study was to determine whether infiltration of local anesthetics with adrenaline improved septoplasty procedure when compared to normal saline. Eight-two patients undergoing septoplasty were randomized into two groups. In group 1, septal mucoperichondrium was infiltrated with lidocaine with adrenaline, and normal saline was used in group 2. Presence of intra-operative septal mucosal injuries, the amount of bleeding, arterial blood pressure, operation time as well as the quality of the surgical field and the convenience of finding the correct surgical plane as determined by the surgeon using a 5-point scale were compared between two groups. There were no significant differences for the amount of blood loss, mean arterial pressure, operation time, or scores for convenience of finding the correct surgical plane between the two groups. There was no significant difference for intra-operative simple (P = 0.631) and total (simple+severe) (P = 0.649) septal mucoperichondrial injuries between groups 1 and 2, either. However, severe mucoperichondrial injury rate was higher in the patients infiltrated with lidocaine and adrenaline (P = 0.026), and the quality of the surgical field was worse in the patients injected with normal saline (P = 0.0179). Infiltration of septal mucoperichondrium with lidocaine and adrenaline instead of normal saline was not advantageous in terms of objective parameters tested, including bleeding amount and duration of surgery as well as the of the total mucosal injury rate in septoplasty procedure.

  6. Interrelations among the adipocytokines leptin and adiponectin, oxidative stress and aseptic inflammation markers in pre- and early-pubertal normal-weight and obese boys.

    PubMed

    Paltoglou, George; Schoina, Maria; Valsamakis, George; Salakos, Nicolaos; Avloniti, Alexandra; Chatzinikolaou, Athanasios; Margeli, Alexandra; Skevaki, Chrysanthi; Papagianni, Maria; Kanaka-Gantenbein, Christina; Papassotiriou, Ioannis; Chrousos, George P; Fatouros, Ioannis G; Mastorakos, George

    2017-03-01

    Presumed interrelationships among deleterious aspects of adipose tissue metabolism, inflammation, and cellular oxidative stress could be influenced by pubertal hormonal changes. They were investigated in pre- and early pubertal normal-weight and obese boys before and after an exercise bout employed as an energy demanding stimulator. Cross-sectional study. Seventy-six healthy pre- (mean ± SD, 10.6 ± 0.2 years old, 28 normal-weight, and 11 obese) and early-(11.4 ± 0.2 years old, 25 normal-weight, and 12 obese) pubertal boys, were blood-sampled before and after a bout of exercise at 70% VO 2 max. Leptin, adiponectin, markers of inflammation (high-sensitivity C-reactive protein, high sensitivity IL-6), pro- (thiobarbitouric acid reactive substances, protein carbonyls) and anti- (glutathione, oxidized glutathione, glutathione peroxidase, catalase, total antioxidant capacity) oxidation were measured. Baseline and post-exercise adiponectin was greater and leptin and high-sensitivity C-reactive protein were lower in normal-weight than in obese pre- and early pubertal boys, while high sensitivity IL-6 was greater in obese than in normal-weight pre-pubertal boys. In pre-pubertal obese boys: at baseline, high-sensitivity C-reactive protein correlated negatively with catalase; high sensitivity IL-6 correlated positively with protein carbonyls; Δ (difference during exercise) adiponectin correlated positively with Δcatalase. In all boys: at baseline, high sensitivity IL-6 correlated positively with leptin and was the best negative and the second best positive predictor for post-exercise glutathione/oxidized glutathione and protein carbonyls, respectively; leptin was the best negative predictor for post-exercise glutathione; waist to height ratio was the best positive predictor for post-exercise thiobarbitouric acid reactive substances; body mass index z-score and adiponectin were, respectively, the best positive predictor for post-exercise protein carbonyls and catalase. In all subjects, leptin and adiponectin predict negatively and positively anti-oxidation, respectively, while high sensitivity IL-6 predicts positively and negatively pro- and anti-oxidation, respectively. High-sensitivity C-reactive protein is increased and negatively associated with anti-oxidation in pre-pubertal obese boys, suggesting that childhood obesity is associated with aseptic inflammation and oxidative stress.

  7. Validation of a noninvasive test routinely used in otology for the diagnosis of cerebrospinal fluid shunt malfunction in patients with normal pressure hydrocephalus.

    PubMed

    Sakka, Laurent; Chomicki, Alexandre; Gabrillargues, Jean; Khalil, Toufic; Chazal, Jean; Avan, Paul

    2016-02-01

    Ventriculoperitoneal shunting is the first-line treatment for normal pressure hydrocephalus. Noninvasive auditory tests based on recorded otoacoustic emissions were assessed, as currently used for universal neonatal hearing screenings, for the diagnosis of cerebrospinal fluid shunt malfunction. The test was designed based on previous works, which demonstrated that an intracranial pressure change induces a proportional, characteristic, otoacoustic-emission phase shift. Forty-four patients with normal pressure hydrocephalus (23 idiopathic and 21 secondary cases) were included in this prospective observational study. The male:female sex ratio was 1.44, the age range was 21-87 years (mean age 64.3 years), and the range of the follow-up period was 1-3 years (mean 20 months). Patients were implanted with a Sophy SU8 adjustable-pressure valve as the ventriculoperitoneal shunt. The phase shifts of otoacoustic emissions in response to body tilt were measured preoperatively, immediately postoperatively, and at 3-6 months, 7-15 months, 16-24 months, and more than 24 months postoperatively. Three groups were enrolled: Group 1, 19 patients who required no valve opening-pressure adjustment; Group 2, 18 patients who required valve opening-pressure adjustments; and Group 3, 7 patients who required valve replacement. In Group 1, phase shift, which was positive before surgery, became steadily negative after surgery and during the follow-up. In Group 2, phase shift, which was positive before surgery, became negative immediately after surgery and increasingly negative after a decrease in the valve-opening pressure. In Group 3, phase shift was positive in 6 cases and slightly negative in 1 case before revision, but after revision phase shift became significantly negative in all cases. Otoacoustic emissions noninvasively reflect cerebrospinal fluid shunt function and are impacted by valve-opening pressure adjustments. Otoacoustic emissions consistently diagnosed shunt malfunction and predicted the need for surgical revision. The authors' diagnostic test, which can be repeated without risk or discomfort by an unskilled operator, may address the crucial need of detecting valve dysfunction in patients with poor clinical outcome after shunt surgery.

  8. The Utility of Recurrent Laryngeal Nerve Monitoring During Open Pharyngeal Diverticula Procedures.

    PubMed

    Coughlan, Carolyn A; Verma, Sunil P

    2016-08-01

    The recurrent laryngeal nerve is at risk of injury during open pharyngeal diverticula operations. The utility of recurrent laryngeal nerve (RLN) monitoring during these procedures was investigated. A retrospective chart review was performed of 8 open pharyngeal diverticulectomies completed between 2009 and 2014. Intraoperative RLN monitoring took place during all operations. Open pharyngectomy and myotomy was successfully performed in all cases. In two cases the RLN was encountered outside of its normal course. The identity of the nerve was confirmed with electrical stimulation and normal EMG response. Vocal fold motion was preserved in all cases. Use of intraoperative nerve monitoring in pharyngeal diverticula procedures may be beneficial, especially during open operations for Killian-Jamieson diverticulum (KJD) and large Zenker diverticulum (ZD), where the RLN is typically encountered outside of its normal course. © The Author(s) 2016.

  9. Man-vehicle systems research facility advanced aircraft flight simulator throttle mechanism

    NASA Technical Reports Server (NTRS)

    Kurasaki, S. S.; Vallotton, W. C.

    1985-01-01

    The Advanced Aircraft Flight Simulator is equipped with a motorized mechanism that simulates a two engine throttle control system that can be operated via a computer driven performance management system or manually by the pilots. The throttle control system incorporates features to simulate normal engine operations and thrust reverse and vary the force feel to meet a variety of research needs. While additional testing to integrate the work required is principally now in software design, since the mechanical aspects function correctly. The mechanism is an important part of the flight control system and provides the capability to conduct human factors research of flight crews with advanced aircraft systems under various flight conditions such as go arounds, coupled instrument flight rule approaches, normal and ground operations and emergencies that would or would not normally be experienced in actual flight.

  10. 14 CFR 23.1583 - Operating limitations.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... multiengine jets 6,000 pounds or less maximum weight in the normal, utility, and acrobatic category... climb requirements of § 23.63(c)(2). (4) For normal, utility, and acrobatic category multiengine jets... equal to the available runway length. (5) For normal, utility, and acrobatic category multiengine jets...

  11. 14 CFR 23.1583 - Operating limitations.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... multiengine jets 6,000 pounds or less maximum weight in the normal, utility, and acrobatic category... climb requirements of § 23.63(c)(2). (4) For normal, utility, and acrobatic category multiengine jets... equal to the available runway length. (5) For normal, utility, and acrobatic category multiengine jets...

  12. Automatic classification of small bowel mucosa alterations in celiac disease for confocal laser endomicroscopy

    NASA Astrophysics Data System (ADS)

    Boschetto, Davide; Di Claudio, Gianluca; Mirzaei, Hadis; Leong, Rupert; Grisan, Enrico

    2016-03-01

    Celiac disease (CD) is an immune-mediated enteropathy triggered by exposure to gluten and similar proteins, affecting genetically susceptible persons, increasing their risk of different complications. Small bowels mucosa damage due to CD involves various degrees of endoscopically relevant lesions, which are not easily recognized: their overall sensitivity and positive predictive values are poor even when zoom-endoscopy is used. Confocal Laser Endomicroscopy (CLE) allows skilled and trained experts to qualitative evaluate mucosa alteration such as a decrease in goblet cells density, presence of villous atrophy or crypt hypertrophy. We present a method for automatically classifying CLE images into three different classes: normal regions, villous atrophy and crypt hypertrophy. This classification is performed after a features selection process, in which four features are extracted from each image, through the application of homomorphic filtering and border identification through Canny and Sobel operators. Three different classifiers have been tested on a dataset of 67 different images labeled by experts in three classes (normal, VA and CH): linear approach, Naive-Bayes quadratic approach and a standard quadratic analysis, all validated with a ten-fold cross validation. Linear classification achieves 82.09% accuracy (class accuracies: 90.32% for normal villi, 82.35% for VA and 68.42% for CH, sensitivity: 0.68, specificity 1.00), Naive Bayes analysis returns 83.58% accuracy (90.32% for normal villi, 70.59% for VA and 84.21% for CH, sensitivity: 0.84 specificity: 0.92), while the quadratic analysis achieves a final accuracy of 94.03% (96.77% accuracy for normal villi, 94.12% for VA and 89.47% for CH, sensitivity: 0.89, specificity: 0.98).

  13. Disruption of Desmin-Mitochondrial Architecture in Patients with Regurgitant Mitral Valves and Preserved Ventricular Function

    PubMed Central

    Soorappan, Rajasekaran Namakkal; Ahmad, Shama; Mariappan, Nithya; Litovsky, Silvio; Gupta, Himanshu; Lloyd, Steven G; Denney, Thomas S; Powell, Pamela Cox; Aban, Inmaculada; Collawn, James; Davies, James E; McGiffin, David C; Dell’Italia, Louis J

    2016-01-01

    Objective Recent studies have demonstrated improved outcomes in patients receiving early surgery for degenerative mitral valvular regurgitation (MR) rather than adhering to conventional guidelines for surgical intervention. However, studies providing a mechanistic basis for these findings are limited. Methods Left ventricular (LV) myocardium from 22 patients undergoing mitral valve repair for Class I indications was evaluated for desmin, the voltage-dependent anion channel, αβ-crystallin, and α, β unsaturated aldehyde 4-hydroxynonelal by fluorescence microscopy and in 6 normal control LV autopsy specimens. Cardiomyocyte ultrastructure was examined by transmission electron microscopy. Magnetic resonance imaging with tissue tagging was performed in 55 normal subjects and 22 MR patients pre- and 6 months post-mitral valve repair. Results LV end-diastolic volume was 1.5-fold (p<0.0001) higher and LV mass to volume ratio was lower in MR (p=0.004) vs. normal and improvement six months after mitral valve surgery. However, LV ejection fraction decreased from 65 ± 7 to 52 ± 9% (p<0.0001) and LV circumferential (p<0.0001) and longitudinal strain decreased significantly below normal values (p=0.002) post-surgery. MR hearts had a 53% decrease in desmin (p<0.0001) and a 2.6-fold increase in desmin aggregates (p<0.0001) vs. normal along with significant, intense perinuclear staining of α, β unsaturated aldehyde 4-hydroxynonelal in areas of mitochondrial breakdown and clustering. Transmission electron microscopy demonstrated numerous electron dense deposits, myofibrillar loss, Z-line abnormalities and extensive granulofilamentous debris identified as desmin positive by immunogold transmission electron microscopy. Conclusion Despite well-preserved preoperative LV ejection fraction, severe oxidative stress and disruption of cardiomyocyte desmin-mitochondrial sarcomeric architecture may explain post-operative LV functional decline and further supports the move toward earlier surgical intervention. PMID:27464577

  14. In-vacuum sensors for the beamline components of the ITER neutral beam test facility.

    PubMed

    Dalla Palma, M; Pasqualotto, R; Sartori, E; Spagnolo, S; Spolaore, M; Veltri, P

    2016-11-01

    Embedded sensors have been designed for installation on the components of the MITICA beamline, the prototype ITER neutral beam injector (Megavolt ITER Injector and Concept Advancement), to derive characteristics of the particle beam and to monitor the component conditions during operation for protection and thermal control. Along the beamline, the components interacting with the particle beam are the neutralizer, the residual ion dump, and the calorimeter. The design and the positioning of sensors on each component have been developed considering the expected beam-surface interaction including non-ideal and off-normal conditions. The arrangement of the following instrumentation is presented: thermal sensors, strain gages, electrostatic probes including secondary emission detectors, grounding shunt for electrical currents, and accelerometers.

  15. Construction concept for erecting an offset-fed antenna

    NASA Technical Reports Server (NTRS)

    Rhodes, M. D.

    1984-01-01

    A design concept for the construction of an offset-fed antenna is discussed. Antennas of this type are of interest for space applications because the configuration eliminates the effects of feed and feed-support blockage. The proposed construction concept is developed around the assembly of a stiff truss substructure by pressure-suited astronauts operating in extravehicular activity (EVA) assisted by a mobile platform that moves along the structure to position the astronauts at joint locations where they can latch members in place. Construction can be accomplished from the shuttle cargo bay in the course of a normal flight or from a space station platform. The concepts demonstrates the versatility of machine assisted manned assembly and is only one of many potential applications.

  16. Gallium-67 scintigraphy and intraabdominal sepsis. Clinical experience in 140 patients with suspected intraabdominal abscess

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hopkins, G.B.; Kan, M.; Mende, C.W.

    In 140 patients with suspected intraabdominal abscess, studies were made using gallium-67 citrate and technetium-99m labeled radiopharmaceuticals. Gallium-67 scintigrams correctly localized 52 of 56 intraabdominal abscesses confirmed at surgical operation or necropsy. In an additional 20 patients in whom findings on scintigrams were abnormal, there were clinically established infections. Sixty-one patients in whom findings on scintigrams were normal were conservatively managed and discharged from the hospital; none proved to have an abscess. Four false-negative and three false-positive studies were recorded. Gallium-67 scintigraphy is a useful noninvasive diagnostic adjunct that should be employed early in the evaluation of patients with suspectedmore » intraabdominal sepsis.« less

  17. A feminist response to Weitzer.

    PubMed

    Dines, Gail

    2012-04-01

    In his review of my book Pornland: How Porn has Hijacked our Sexuality, Ronald Weitzer claims that anti-porn feminists are incapable of objective, rigorous research because they operate within the "oppression paradigm," which he defines as "a perspective that depicts all types of sex work as exploitive, violent, and perpetuating gender inequality." (VAW, 2011, 666). This article argues that while anti-porn feminists do indeed see pornography as exploitive, such a position is rooted in the rigorous theories and methods of cultural studies developed by critical media scholars such as Stuart Hall and Antonio Gramsci. Pornland applies a cultural studies approach by exploring how porn images are part of a wider system of sexist representations that legitimize and normalize the economic, political and legal oppression of women.

  18. ROS in Cancer: The Burning Question

    PubMed Central

    2017-01-01

    Summary An unanswered question in human health is whether anti-oxidation prevents or promotes cancer. Anti-oxidation has historically been viewed as chemo-preventive but emerging evidence suggests that antioxidants may be supportive of neoplasia. We posit this contention to be rooted in the fact that ROS do not operate as one single biochemical entity, but as diverse secondary messengers in cancer cells. This cautions against therapeutic strategies to increase ROS at a global level. To leverage redox alterations towards the development of effective therapies necessitates the application of biophysical and biochemical approaches to define redox dynamics and to functionally elucidate specific oxidative modifications in cancer versus normal cells. An improved understanding of the sophisticated workings of redox biology is imperative to defeating cancer. PMID:28427863

  19. Magnetic Resonance Imaging (MRI) Evaluation for Anterior Disc Displacement of the Temporomandibular Joint.

    PubMed

    Yang, Zhongjun; Wang, Mingguo; Ma, Yingwei; Lai, Qingguo; Tong, Dongdong; Zhang, Fenghe; Dong, Lili

    2017-02-08

    BACKGROUND Magnetic resonance imaging (MRI) is the criterion standard imaging technique for visualization of the temporomandibular joint (TMJ) region, and is currently considered the optimum modality for comprehensive evaluation in patients with temporomandibular joint disorder (TMD). This study was aimed at finding the value of MRI in pre-clinical diagnosis of TMJ disc displacement. MATERIAL AND METHODS Patients primarily diagnosed as having anterior disc displacement by clinical symptoms and X-ray were selected in the present study. MRI was used to evaluate surrounding anatomical structures and position, as well as morphological and signal intensity change between patients and normal controls. RESULTS Posterior band position was significantly different between the patient group and control group. At the maximum opened-mouth position, the location of disc intermediate zone returned to normal. At closed-mouth position, the thickness of anterior and middle, but not posterior, band increased. The motion range of the condyle in the anterior disc displacement without reduction (ADDWR) patient group was significantly less than the value in the anterior disc displacement with reduction (ADDR) patient group and the control group. Whether at closed-mouth position or maximum opened-mouth position, the exudate volume in the patient group was greater than in the normal group. CONCLUSIONS MRI can be successfully used to evaluate multiple morphological changes at different mouth positions of normal volunteers and patients. The disc-condyle relationship can serve as an important indicator in assessing anterior disc displacement, and can be used to distinguish disc displacement with or without reduction.

  20. Magnetic Resonance Imaging (MRI) Evaluation for Anterior Disc Displacement of the Temporomandibular Joint

    PubMed Central

    Yang, Zhongjun; Wang, Mingguo; Ma, Yingwei; Lai, Qingguo; Tong, Dongdong; Zhang, Fenghe; Dong, Lili

    2017-01-01

    Background Magnetic resonance imaging (MRI) is the criterion standard imaging technique for visualization of the temporomandibular joint (TMJ) region, and is currently considered the optimum modality for comprehensive evaluation in patients with temporomandibular joint disorder (TMD). This study was aimed at finding the value of MRI in pre-clinical diagnosis of TMJ disc displacement. Material/Methods Patients primarily diagnosed as having anterior disc displacement by clinical symptoms and X-ray were selected in the present study. MRI was used to evaluate surrounding anatomical structures and position, as well as morphological and signal intensity change between patients and normal controls. Results Posterior band position was significantly different between the patient group and control group. At the maximum opened-mouth position, the location of disc intermediate zone returned to normal. At closed-mouth position, the thickness of anterior and middle, but not posterior, band increased. The motion range of the condyle in the anterior disc displacement without reduction (ADDWR) patient group was significantly less than the value in the anterior disc displacement with reduction (ADDR) patient group and the control group. Whether at closed-mouth position or maximum opened-mouth position, the exudate volume in the patient group was greater than in the normal group. Conclusions MRI can be successfully used to evaluate multiple morphological changes at different mouth positions of normal volunteers and patients. The disc-condyle relationship can serve as an important indicator in assessing anterior disc displacement, and can be used to distinguish disc displacement with or without reduction. PMID:28176754

Top