DOE Office of Scientific and Technical Information (OSTI.GOV)
Hassanein, A.; Konkashbaev, I.
1999-03-15
The structure of a collisionless scrape-off-layer (SOL) plasma in tokamak reactors is being studied to define the electron distribution function and the corresponding sheath potential between the divertor plate and the edge plasma. The collisionless model is shown to be valid during the thermal phase of a plasma disruption, as well as during the newly desired low-recycling normal phase of operation with low-density, high-temperature, edge plasma conditions. An analytical solution is developed by solving the Fokker-Planck equation for electron distribution and balance in the SOL. The solution is in good agreement with numerical studies using Monte-Carlo methods. The analytical solutionsmore » provide an insight to the role of different physical and geometrical processes in a collisionless SOL during disruptions and during the enhanced phase of normal operation over a wide range of parameters.« less
Progress of long pulse operation with high performance plasma in KSTAR
NASA Astrophysics Data System (ADS)
Bae, Young; Kstar Team
2015-11-01
Recent KSTAR experiments showed the sustained H-mode operation up to the pulse duration of 46 s at the plasma current of 600 kA. The long-pulse H-mode operation has been supported by long-pulse capable neutral beam injection (NBI) system with high NB current drive efficiency attributed by highly tangential injections of three beam sources. In next phase, aiming to demonstrate the long pulse stationary high performance plasma operation, we are attempting the long pulse inductive operation at the higher performance (MA plasma current, high normalized beta, and low q95) for the final goal of demonstration of ITER-like baseline scenario in KSTAR with progressive improvement of the plasma shape control and higher neutral beam injection power. This paper presents the progress of long pulse operation and the analysis of energy confinement time and non-inductive current drive in KSTAR.
The effects of magnetic nozzle configurations on plasma thrusters
NASA Technical Reports Server (NTRS)
York, Thomas M.
1989-01-01
Plasma thrusters have been operated at power levels from 10kW to 0.1MW. When these devices have had magnetic fields applied to them which form a nozzle configuration for the expanding plasma, they have shown marked increases in exhaust velocity which is in direct proportion to the magnitude of the applied field. Further, recent results have shown that electrode erosion may be influenced by applied magnetic fields. This research is directed to the experimental and computational study of the effects of applied magnetic field nozzles in the acceleration of plasma flows. Plasma source devices which eliminate the plasma interaction in normal thrusters are studied as most basic. Normal thruster configurations will be studied without applied fields and with applied magnetic nozzle fields. Unique computational studies will utilize existing codes which accurately include transport processes. Unique diagnostic studies will support the experimental studies to generate new data. Both computation and diagnostics will be combined to indicate the physical mechanisms and transport properties that are operative in order to allow scaling and accurate prediction of thruster performance.
Eizayaga, Francisco; Scorticati, Camila; Prestifilippo, Juan P; Romay, Salvador; Fernandez, Maria A; Castro, José L; Lemberg, Abraham; Perazzo, Juan C
2006-01-01
AIM: To study the blood-brain barrier integrity in prehepatic portal hypertensive rats induced by partial portal vein ligation, at 14 and 40 d after ligation when portal pressure is spontaneously normalized. METHODS: Adult male Wistar rats were divided into four groups: Group I: Sham14d , sham operated; Group II: PH14d , portal vein stenosis; (both groups were used 14 days after surgery); Group III: Sham40d, Sham operated and Group IV: PH40d Portal vein stenosis (Groups II and IV used 40 d after surgery). Plasma ammonia, plasma and cerebrospinal fluid protein and liver enzymes concentrations were determined. Trypan and Evans blue dyes, systemically injected, were investigated in hippocampus to study blood-brain barrier integrity. Portal pressure was periodically recorded. RESULTS: Forty days after stricture, portal pressure was normalized, plasma ammonia was moderately high, and both dyes were absent in central nervous system parenchyma. All other parameters were reestablished. When portal pressure was normalized and ammonia level was lowered, but not normal, the altered integrity of blood-brain barrier becomes reestablished. CONCLUSION: The impairment of blood-brain barrier and subsequent normalization could be a mechanism involved in hepatic encephalopathy reversibility. Hemodynamic changes and ammonia could trigger blood-brain barrier alterations and its reestablishment. PMID:16552803
DNA damage in oral cancer cells induced by nitrogen atmospheric pressure plasma jets
NASA Astrophysics Data System (ADS)
Han, Xu; Klas, Matej; Liu, Yueying; Stack, M. Sharon; Ptasinska, Sylwia
2013-09-01
The nitrogen atmospheric pressure plasma jet (APPJ) has been shown to effectively induce DNA double strand breaks in SCC-25 oral cancer cells. The APPJ source constructed in our laboratory consists of two external electrodes wrapping around a quartz tube and nitrogen as a feed gas and operates based on dielectric barrier gas discharge. Generally, it is more challenging to ignite plasma in N2 atmosphere than in noble gases. However, this design provides additional advantages such as lower costs compared to the noble gases for future clinical operation. Different parameters of the APPJ configuration were tested in order to determine radiation dosage. To explore the effects of delayed damage and cell self-repairing, various incubation times of cells after plasma treatment were also performed. Reactive species generated in plasma jet and in liquid environment are essential to be identified and quantified, with the aim of unfolding the mystery of detailed mechanisms for plasma-induced cell apoptosis. Moreover, from the comparison of plasma treatment effect on normal oral cells OKF6T, an insight to the selectivity for cancer treatment by APPJ can be explored. All of these studies are critical to better understand the damage responses of normal and abnormal cellular systems to plasma radiation, which are useful for the development of advanced plasma therapy for cancer treatment at a later stage.
Cold atmospheric plasma jet-generated RONS and their selective effects on normal and carcinoma cells
Kim, Sun Ja; Chung, T. H.
2016-01-01
Cold atmospheric helium plasma jets were fabricated and utilized for plasma–cell interactions. The effect of operating parameters and jet design on the generation of specific reactive oxygen and nitrogen species (RONS) within cells and cellular response were investigated. It was found that plasma treatment induced the overproduction of RONS in various cancer cell lines selectively. The plasma under a relatively low applied voltage induced the detachment of cells, a reduction in cell viability, and apoptosis, while the plasma under higher applied voltage led to cellular necrosis in our case. To determine whether plasma-induced reactive oxygen species (ROS) generation occurs through interfering with mitochondria-related cellular response, we examined the plasma effects on ROS generation in both parental A549 cells and A549 ρ0 cells. It was observed that cancer cells were more susceptible to plasma-induced RONS (especially nitric oxide (NO) and nitrogen dioxide (NO2−) radicals) than normal cells, and consequently, plasma induced apoptotic cell responses mainly in cancer cells. PMID:26838306
Emittance measurements for optimum operation of the J-PARC RF-driven H{sup −} ion source
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ueno, A., E-mail: akira.ueno@j-parc.jp; Ohkoshi, K.; Ikegami, K.
2015-04-08
In order to satisfy the Japan Proton Accelerator Research Complex (J-PARC) second stage requirements of an H{sup −} ion beam of 60mA within normalized emittances of 1.5πmm•mrad both horizontally and vertically, a flat top beam duty factor of 1.25% (500μs×25Hz) and a life-time of longer than 1month, the J-PARC cesiated RF-driven H{sup −} ion source was developed by using an internal-antenna developed at the Spallation Neutron Source (SNS). The transverse emittances of the source were measured with various conditions to find out the optimum operation conditions minimizing the horizontal and vertical rms normalized emittances. The transverse emittances were most effectivelymore » reduced by operating the source with the plasma electrode temperature lower than 70°C. The optimum value of the cesium (Cs) density around the beam hole of the plasma electrode seems to be proportional to the plasma electrode temperature. The fine control of the Cs density is indispensable, since the emittances seem to increase proportionally to the excessiveness of the Cs density. Furthermore, the source should be operated with the Cs density beyond a threshold value, since the plasma meniscus shape and the ellipse parameters of the transverse emittances seem to be changed step-function-likely on the threshold Cs value.« less
Investigation of MHD instabilities and control in KSTAR preparing for high beta operation
NASA Astrophysics Data System (ADS)
Park, Y. S.; Sabbagh, S. A.; Bialek, J. M.; Berkery, J. W.; Lee, S. G.; Ko, W. H.; Bak, J. G.; Jeon, Y. M.; Park, J. K.; Kim, J.; Hahn, S. H.; Ahn, J.-W.; Yoon, S. W.; Lee, K. D.; Choi, M. J.; Yun, G. S.; Park, H. K.; You, K.-I.; Bae, Y. S.; Oh, Y. K.; Kim, W.-C.; Kwak, J. G.
2013-08-01
Initial H-mode operation of the Korea Superconducting Tokamak Advanced Research (KSTAR) is expanded to higher normalized beta and lower plasma internal inductance moving towards design target operation. As a key supporting device for ITER, an important goal for KSTAR is to produce physics understanding of MHD instabilities at long pulse with steady-state profiles, at high normalized beta, and over a wide range of plasma rotation profiles. An advance from initial plasma operation is a significant increase in plasma stored energy and normalized beta, with Wtot = 340 kJ, βN = 1.9, which is 75% of the level required to reach the computed ideal n = 1 no-wall stability limit. The internal inductance was lowered to 0.9 at sustained H-mode duration up to 5 s. In ohmically heated plasmas, the plasma current reached 1 MA with prolonged pulse length up to 12 s. Rotating MHD modes are observed in the device with perturbations having tearing rather than ideal parity. Modes with m/n = 3/2 are triggered during the H-mode phase but are relatively weak and do not substantially reduce Wtot. In contrast, 2/1 modes to date only appear when the plasma rotation profiles are lowered after H-L back-transition. Subsequent 2/1 mode locking creates a repetitive collapse of βN by more than 50%. Onset behaviour suggests the 3/2 mode is close to being neoclassically unstable. A correlation between the 2/1 mode amplitude and local rotation shear from an x-ray imaging crystal spectrometer suggests that the rotation shear at the mode rational surface is stabilizing. As a method to access the ITER-relevant low plasma rotation regime, plasma rotation alteration by n = 1, 2 applied fields and associated neoclassical toroidal viscosity (NTV) induced torque is presently investigated. The net rotation profile change measured by a charge exchange recombination diagnostic with proper compensation of plasma boundary movement shows initial evidence of non-resonant rotation damping by the n = 1, 2 applied field configurations. The result addresses perspective on access to low rotation regimes for MHD instability studies applicable to ITER. Computation of active RWM control using the VALEN-3D code examines control performance using midplane locked mode detection sensors. The LM sensors are found to be strongly affected by mode and control coil-induced vessel current, and consequently lead to limited control performance theoretically.
[A case of GH and TSH secreting pituitary macroadenoma].
Gołkowski, Filip; Buziak-Bereza, Monika; Stefańska, Agnieszka; Trofimiuk, Małgorzata; Pantofliński, Jacek; Huszno, Bohdan; Czepko, Ryszard; Adamek, Dariusz
2006-01-01
A case of GH and TSH secreting pituitary macroadenoma is reported. A 45-year-old female presented clinical features of acromegaly (the abnormal growth of the hands and feet, with lower jaw protrusion), diabetes mellitus, hypertension, nodular goiter and hyperthyroidism of unclear origin. NMR pituitary imaging revealed intra and extrasellar tumor. The laboratory examinations showed very high plasma levels of GH and IGF-1 and normal level of TSH coexisting with high plasma levels of free thyroid hormones. Pharmacological pretreatment with somatostatin analogues caused the substantial reduction of GH and TSH plasma levels. Histological and immunohistochemical examination of the tissue obtained at transsphenoidal surgery showed GH and TSH secreting adenoma. The laboratory examinations after surgery showed normal GH and IGF-1 plasma levels and reduced insulin requirement, what indicates radical operation. The very low plasma levels of TSH and free thyroid hormones after surgery and immunohistochemical examination suggest central hyperthyroidism due to TSH secreting pituitary tumor (thyrotropinoma).
Lundgren, Jakob; Sandqvist, Anna; Hedeland, Mikael; Bondesson, Ulf; Wikström, Gerhard; Rådegran, Göran
2018-04-12
Endothelial function, including the nitric oxide (NO)-pathway, has previously been extensively investigated in heart failure (HF). In contrast, studies are lacking on the NO pathway after heart transplantation (HT). We therefore investigated substances in the NO pathway prior to and after HT in relation to hemodynamic parameters. 12 patients (median age 50.0 yrs, 2 females), heart transplanted between June 2012 and February 2014, evaluated at our hemodynamic lab, at rest, prior to HT, as well as four weeks and six months after HT were included. All patients had normal left ventricular function post-operatively and none had post-operative pulmonary hypertension or acute cellular rejection requiring therapy at the evaluations. Plasma concentrations of ADMA, SDMA, L-Arginine, L-Ornithine and L-Citrulline were analyzed at each evaluation. In comparison to controls, the plasma L-Arginine concentration was low and ADMA high in HF patients, resulting in low L-Arginine/ADMA-ratio pre-HT. Already four weeks after HT L-Arginine was normalized whereas ADMA remained high. Consequently the L-Arginine/ADMA-ratio improved, but did not normalize. The biomarkers remained unchanged at the six-month evaluation and the L-Arginine/ADMA-ratio correlated inversely to pulmonary vascular resistance (PVR) six months post-HT. Plasma L-Arginine concentrations normalize after HT. However, as ADMA is unchanged, the L-Arginine/ADMA-ratio remained low and correlated inversely to PVR. Together these findings suggest that (i) the L-Arginine/ADMA-ratio may be an indicator of pulmonary vascular tone after HT, and that (ii) NO-dependent endothelial function is partly restored after HT. Considering the good postoperative outcome, the biomarker levels may be considered "normal" after HT.
Realizing steady-state tokamak operation for fusion energy
NASA Astrophysics Data System (ADS)
Luce, T. C.
2011-03-01
Continuous operation of a tokamak for fusion energy has clear engineering advantages but requires conditions beyond those sufficient for a burning plasma. The fusion reactions and external sources must support both the pressure and the current equilibrium without inductive current drive, leading to demands on stability, confinement, current drive, and plasma-wall interactions that exceed those for pulsed tokamaks. These conditions have been met individually, and significant progress has been made in the past decade to realize scenarios where the required conditions are obtained simultaneously. Tokamaks are operated routinely without disruptions near pressure limits, as needed for steady-state operation. Fully noninductive sustainment with more than half of the current from intrinsic currents has been obtained for a resistive time with normalized pressure and confinement approaching those needed for steady-state conditions. One remaining challenge is handling the heat and particle fluxes expected in a steady-state tokamak without compromising the core plasma performance.
High temperature ion source for an on-line isotope separator
Mlekodaj, Ronald L.
1979-01-01
A reduced size ion source for on-line use with a cyclotron heavy-ion beam is provided. A sixfold reduction in source volume while operating with similar input power levels results in a 2000.degree. C. operating temperature. A combined target/window normally provides the reaction products for ionization while isolating the ion source plasma from the cyclotron beam line vacuum. A graphite felt catcher stops the recoiling reaction products and releases them into the plasma through diffusion and evaporation. Other target arrangements are also possible. A twenty-four hour lifetime of unattended operation is achieved, and a wider range of elements can be studied than was heretofore possible.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hassanein, Ahmed
2015-03-31
This report describes implementation of comprehensive and integrated models to evaluate plasma material interactions during normal and abnormal plasma operations. The models in full3D simulations represent state-of-the art worldwide development with numerous benchmarking of various tokamak devices and plasma simulators. In addition, significant number of experimental work has been performed in our center for materials under extreme environment (CMUXE) at Purdue to benchmark the effect of intense particle and heat fluxes on plasma-facing components. This represents one-year worth of work and resulted in more than 23 Journal Publications and numerous conferences presentations. The funding has helped several students to obtainmore » their M.Sc. and Ph.D. degrees and many of them are now faculty members in US and around the world teaching and conducting fusion research. Our work has also been recognized through many awards.« less
Solar array/spacecraft biasing
NASA Technical Reports Server (NTRS)
Fitzgerald, D. J.
1981-01-01
Biasing techniques and their application to the control of spacecraft potential is discussed. Normally when a spacecraft is operated with ion thrusters, the spacecraft will be 10-20 volts negative of the surrounding plasma. This will affect scientific measurements and will allow ions from the charge-exchange plasma to bombard the spacecraft surfaces with a few tens of volts of energy. This condition may not be tolerable. A proper bias system is described that can bring the spacecraft to or near the potential of the surrounding plasma.
Normally-off p-GaN/AlGaN/GaN high electron mobility transistors using hydrogen plasma treatment
NASA Astrophysics Data System (ADS)
Hao, Ronghui; Fu, Kai; Yu, Guohao; Li, Weiyi; Yuan, Jie; Song, Liang; Zhang, Zhili; Sun, Shichuang; Li, Xiajun; Cai, Yong; Zhang, Xinping; Zhang, Baoshun
2016-10-01
In this letter, we report a method by introducing hydrogen plasma treatment to realize normally-off p-GaN/AlGaN/GaN HEMT devices. Instead of using etching technology, hydrogen plasma was adopted to compensate holes in the p-GaN above the two dimensional electron gas (2DEG) channel to release electrons in the 2DEG channel and form high-resistivity area to reduce leakage current and increase gate control capability. The fabricated p-GaN/AlGaN/GaN HEMT exhibits normally-off operation with a threshold voltage of 1.75 V, a subthreshold swing of 90 mV/dec, a maximum transconductance of 73.1 mS/mm, an ON/OFF ratio of 1 × 107, a breakdown voltage of 393 V, and a maximum drain current density of 188 mA/mm at a gate bias of 6 V. The comparison of the two processes of hydrogen plasma treatment and p-GaN etching has also been made in this work.
Operating characteristics of a hydrogen-argon plasma torch for supersonic combustion applications
NASA Technical Reports Server (NTRS)
Barbi, E.; Mahan, J. R.; O'Brien, W. F.; Wagner, T. C.
1989-01-01
The residence time of the combustible mixture in the combustion chamber of a scramjet engine is much less than the time normally required for complete combustion. Hydrogen and hydrocarbon fuels require an ignition source under conditions typically found in a scramjet combustor. Analytical studies indicate that the presence of hydrogen atoms should greatly reduce the ignition delay in this environment. Because hydrogen plasmas are prolific sources of hydrogen atoms, a low-power, uncooled hydrogen plasma torch has been built and tested to evaluate its potential as a possible flame holder for supersonic combustion. The torch was found to be unstable when operated on pure hydrogen; however, stable operation could be obtained by using argon as a body gas and mixing in the desired amount of hydrogen. The stability limits of the torch are delineated and its electrical and thermal behavior documented. An average torch thermal efficiency of around 88 percent is demonstrated.
Integrated Plasma Control for Alternative Plasma Shape on EAST
NASA Astrophysics Data System (ADS)
Xiao, Bingjia
2017-10-01
To support long pulse plasma operation in high performance, a set of plasma control algorithms such as PEFIT real-time equilibrium reconstruction, radiation feedback, Beta and loop voltage feedback and quasi-snowflake shape f control have been implemented on EAST Plasma Control system (PCS) which was adapted from DIII-D PCS. PEFIT is a parallelized version of EFIT by using GPU with highest computation acceleration ratio up to 100 with respect to EFIT. It demonstrated high performance both in DIII-D data analysis and in the real-time shape control on EAST plasma either in normal or quasi-snowflake shape. Loop voltage has been successfully controlled by Low Hybrid Wave (LHW) while the plasma current is maintained by poloidal field coil set. Beta control has been also demonstrated by using LHW and it will be extended to other heating sources because the PCS interface is ready. Radiation feedback control has been achieved by Neon seeding by Super-Sonic Molecular Beam Injection (SMBI). For the plasma operation in quasi-snowflake, we have reached 20 s ELMy free high confinement non-inductive discharges with betap 2, H98 1.1 and plasma current 250 kA. EAST orals.
Age-related changes in factor VII proteolysis in vivo.
Ofosu, F A; Craven, S; Dewar, L; Anvari, N; Andrew, M; Blajchman, M A
1996-08-01
Previous studies have reported that pre-operative plasmas of patients over the age of 40 years who developed post-operative deep vein thrombosis (DVT) had approximately twice the amount of proteolysed factor VII found in plasmas of patients in whom prophylaxis with heparin or low M(r) heparin was successful. These and other studies also reported higher concentrations of thrombin-antithrombin III in pre- and post-operative plasmas of patients who developed post-operative thrombosis than in plasmas of patients in whom prophylaxis was successful. Whether the extent of factor VII proteolysis seen in the patients who developed post-operative DVT is related to the severity of their disease or age is not known. This report investigated age-related changes in the concentrations of total factor VII protein, factor VII zymogen, factor VIIa, tissue factor pathway inhibitor, thrombin-antithrombin III, and prothrombin fragment 1 + 2 in normal plasmas and the relationships between these parameters. With the exception of thrombin-antithrombin III, statistically significant increases in the concentrations of these parameters with age were found. Additionally, the differences between the concentrations of total factor VII protein and factor VII zymogen, an index factor VII proteolysis in vivo, were statistically significant only for individuals over age 40. Using linear regression analysis, a significant correlation was found to exist between the concentrations of plasma factor VIIa and prothrombin fragment 1 + 2. Since factor VIIa-tissue factor probably initiates coagulation in vivo, we hypothesize that the elevated plasma factor VIIa (reflecting a less tightly regulated tissue factor activity and therefore increased thrombin production in vivo) accounts for the high risk for post-operative thrombosis seen in individuals over the age of 40.
The hormone prolactin (PRL) plays a critical role in normal breast development by stimulating the proliferation of mammary cells, the production of milk proteins, and the formation of new mammary blood vessels. Unfortunately, the same cell and vessel growth pathways controlled by PRL in normal cells also operate in breast cancer cells, and elevated plasma PRL is a risk factor
Development of advanced high heat flux and plasma-facing materials
NASA Astrophysics Data System (ADS)
Linsmeier, Ch.; Rieth, M.; Aktaa, J.; Chikada, T.; Hoffmann, A.; Hoffmann, J.; Houben, A.; Kurishita, H.; Jin, X.; Li, M.; Litnovsky, A.; Matsuo, S.; von Müller, A.; Nikolic, V.; Palacios, T.; Pippan, R.; Qu, D.; Reiser, J.; Riesch, J.; Shikama, T.; Stieglitz, R.; Weber, T.; Wurster, S.; You, J.-H.; Zhou, Z.
2017-09-01
Plasma-facing materials and components in a fusion reactor are the interface between the plasma and the material part. The operational conditions in this environment are probably the most challenging parameters for any material: high power loads and large particle and neutron fluxes are simultaneously impinging at their surfaces. To realize fusion in a tokamak or stellarator reactor, given the proven geometries and technological solutions, requires an improvement of the thermo-mechanical capabilities of currently available materials. In its first part this article describes the requirements and needs for new, advanced materials for the plasma-facing components. Starting points are capabilities and limitations of tungsten-based alloys and structurally stabilized materials. Furthermore, material requirements from the fusion-specific loading scenarios of a divertor in a water-cooled configuration are described, defining directions for the material development. Finally, safety requirements for a fusion reactor with its specific accident scenarios and their potential environmental impact lead to the definition of inherently passive materials, avoiding release of radioactive material through intrinsic material properties. The second part of this article demonstrates current material development lines answering the fusion-specific requirements for high heat flux materials. New composite materials, in particular fiber-reinforced and laminated structures, as well as mechanically alloyed tungsten materials, allow the extension of the thermo-mechanical operation space towards regions of extreme steady-state and transient loads. Self-passivating tungsten alloys, demonstrating favorable tungsten-like plasma-wall interaction behavior under normal operation conditions, are an intrinsic solution to otherwise catastrophic consequences of loss-of-coolant and air ingress events in a fusion reactor. Permeation barrier layers avoid the escape of tritium into structural and cooling materials, thereby minimizing the release of tritium under normal operation conditions. Finally, solutions for the unique bonding requirements of dissimilar material used in a fusion reactor are demonstrated by describing the current status and prospects of functionally graded materials.
Linear study of the nonmodal growth of drift waves in dusty plasmas
DOE Office of Scientific and Technical Information (OSTI.GOV)
Manz, P.; Greiner, F.
2010-06-15
The main effect of dust on drift wave turbulence is the enhancement of the nonadiabaticity. Previous work found that nonmodal behavior is important in the nonadiabatic regime of the drift wave system. Here, the modal and nonmodal properties of the linear Hasegawa-Wakatani system of dusty plasmas are investigated. The non-normality of the linear evolution operator can lead to enhanced transient growth rates compared to the modal growth rates.
Plasma physics analysis of SERT-2 operation
NASA Technical Reports Server (NTRS)
Kaufman, H. R.
1980-01-01
An analysis of the major plasma processes involved in the SERT 2 spacecraft experiments was conducted to aid in the interpretation of recent data. A plume penetration model was developed for neutralization electron conduction to the ion beam and showed qualitative agreement with flight data. In the SERT 2 configuration conduction of neutralization electrons between thrusters was experimentally demonstrated in space. The analysis of this configuration suggests that the relative orientation of the two magnetic fields was an important factor in the observed results. Specifically, the opposed field orientation appeared to provide a high conductivity channel between thrusters and a barrier to the ambient low energy electrons in space. The SERT 2 neutralizer currents with negative neutralizer biases were up to about twice the theoretical prediction for electron collection by the ground screen. An explanation for the higher experimental values was a possible conductive path from the neutralizer plume to a nearby part of the ground screen. Plasma probe measurements of SERT 2 gave the clearest indication of plasma electron temperature, with normal operation being near 5 eV and discharge only operation near 2 eV.
Kitson, Alex P; Marks, Kristin A; Aristizabal Henao, Juan J; Tupling, A Russell; Stark, Ken D
2015-12-01
Menopause is associated with higher plasma and liver triacylglycerol (TAG) and increased risk for cardiovascular disease. Lowering TAG in menopause may be beneficial; however, the mechanism underlying menopause-induced TAG accumulation is not clear. Ovariectomy is a model for menopause and is associated with metabolic alterations and hyperphagia. This study investigated the role of hyperphagia in ovariectomy-induced increases in blood and tissue TAG, as well as differences in lipid metabolism enzymes and resting metabolic measures. It was hypothesized that prevention of hyperphagia would restore blood and tissue TAG, enzyme expression, and metabolic measures to eugonadal levels. Ovariectomized rats were fed ad libitum (OVX + AL) or pair-fed (OVX + PF) relative to sham-operated rats (SHAM) to prevent hyperphagia. OVX + AL had higher TAG concentrations in liver and plasma than SHAM (60% and 50%, respectively), and prevention of hyperphagia in OVX + PF normalized TAG concentrations to SHAM levels in liver, but not plasma. OVX + AL also had 141% higher hepatic stearoyl-CoA desaturase 1 which was almost completely normalized to SHAM levels by pair-feeding, suggesting normalization of hepatic lipid storage. In contrast, skeletal muscle carnitine palmitoyl transferase 1 was 40% lower in OVX + AL than SHAM and was intermediate in OVX + PF, suggesting lower muscle fatty acid oxidation that may underlie the higher plasma TAG in OVX. No differences were seen in energy expenditure, VO2, or VCO2. Overall, this study indicates that prevention of hyperphagia resulting from ovarian hormone withdrawal normalizes hepatic TAG to eugonadal levels but has no effect on ovariectomy-induced increases in plasma TAG. Copyright © 2015 Elsevier Inc. All rights reserved.
Jiang, Hua; Peng, Jin; Zhou, Zhi-yuan; Duan, Yu; Chen, Wei; Cai, Bin; Yang, Hao; Zhang, Wei
2010-09-01
Spinal cord injury (SCI) is a complex trauma that consists of multiple pathological mechanisms involving cytotoxic, oxidation stress and immune-endocrine. This study aimed to establish plasma metabonomics fingerprinting atlas for SCI using (1)H nuclear magnetic resonance (NMR) based metabonomics methodology and principal component analysis techniques. Nine Sprague-Dawley (SD) male rats were randomly divided into SCI, normal and sham-operation control groups. Plasma samples were collected for (1)H NMR spectroscopy 3 days after operation. The NMR data were analyzed using principal component analysis technique with Matlab software. Metabonomics analysis was able to distinguish the three groups (SCI, normal control, sham-operation). The fingerprinting atlas indicated that, compared with those without SCI, the SCI group demonstrated the following characteristics with regard to second principal component: it is made up of fatty acids, myc-inositol, arginine, very low-density lipoprotein (VLDL), low-density lipoprotein (LDL), triglyceride (TG), glucose, and 3-methyl-histamine. The data indicated that SCI results in several significant changes in plasma metabolism early on and that a metabonomics approach based on (1)H NMR spectroscopy can provide a metabolic profile comprising several metabolite classes and allow for relative quantification of such changes. The results also provided support for further development and application of metabonomics technologies for studying SCI and for the utilization of multivariate models for classifying the extent of trauma within an individual.
Helicon normal modes in Proto-MPEX
NASA Astrophysics Data System (ADS)
Piotrowicz, P. A.; Caneses, J. F.; Green, D. L.; Goulding, R. H.; Lau, C.; Caughman, J. B. O.; Rapp, J.; Ruzic, D. N.
2018-05-01
The Proto-MPEX helicon source has been operating in a high electron density ‘helicon-mode’. Establishing plasma densities and magnetic field strengths under the antenna that allow for the formation of normal modes of the fast-wave are believed to be responsible for the ‘helicon-mode’. A 2D finite-element full-wave model of the helicon antenna on Proto-MPEX is used to identify the fast-wave normal modes responsible for the steady-state electron density profile produced by the source. We also show through the simulation that in the regions of operation in which core power deposition is maximum the slow-wave does not deposit significant power besides directly under the antenna. In the case of a simulation where a normal mode is not excited significant edge power is deposited in the mirror region. ).
Helicon normal modes in Proto-MPEX
DOE Office of Scientific and Technical Information (OSTI.GOV)
Piotrowicz, Pawel A.; Caneses, Juan F.; Green, David L.
Here, the Proto-MPEX helicon source has been operating in a high electron density 'helicon-mode'. Establishing plasma densities and magnetic field strengths under the antenna that allow for the formation of normal modes of the fast-wave are believed to be responsible for the 'helicon-mode'. A 2D finite-element full-wave model of the helicon antenna on Proto-MPEX is used to identify the fast-wave normal modes responsible for the steady-state electron density profile produced by the source. We also show through the simulation that in the regions of operation in which core power deposition is maximum the slow-wave does not deposit significant power besidesmore » directly under the antenna. In the case of a simulation where a normal mode is not excited significant edge power is deposited in the mirror region.« less
Helicon normal modes in Proto-MPEX
Piotrowicz, Pawel A.; Caneses, Juan F.; Green, David L.; ...
2018-05-22
Here, the Proto-MPEX helicon source has been operating in a high electron density 'helicon-mode'. Establishing plasma densities and magnetic field strengths under the antenna that allow for the formation of normal modes of the fast-wave are believed to be responsible for the 'helicon-mode'. A 2D finite-element full-wave model of the helicon antenna on Proto-MPEX is used to identify the fast-wave normal modes responsible for the steady-state electron density profile produced by the source. We also show through the simulation that in the regions of operation in which core power deposition is maximum the slow-wave does not deposit significant power besidesmore » directly under the antenna. In the case of a simulation where a normal mode is not excited significant edge power is deposited in the mirror region.« less
The hormone prolactin (PRL) plays a critical role in normal breast development by stimulating the proliferation of mammary cells, the production of milk proteins, and the formation of new mammary blood vessels. Unfortunately, the same cell and vessel growth pathways controlled by PRL in normal cells also operate in breast cancer cells, and elevated plasma PRL is a risk factor for breast cancer, especially in post-menopausal women.
National Spherical Torus Experiment (NSTX) Facility/Diagnostic Overview
NASA Astrophysics Data System (ADS)
Ono, M.
2005-10-01
The capabilities of the NSTX experimental facility and diagnostics continue to improve. The new TF joints are performing well at 4.5 kG. New in-board shaping coils were installed to produce plasmas with simultaneously high elongation ˜2.5 and high triangularity ˜0.8 needed for advanced operation. The EFC/RWM system with six external coils driven by three switching power amplifiers (1 kHz, 6 kA-turn) is now fully operational. With these new tools, we significantly expanded the NSTX operating parameters, achieving the highest controlled elongation of 2.75, a shape factor q95Ip/aBT of 37 MA/m-T, plasma volume of 14 m^3, stored energy of 430 kJ, normalized beta of 7.4 % MA/m-T, bootstrap current fraction of 60 % at 700 kA, and longest plasma pulse length of 1.5 s or about 4 times the resistive skin time. In the area of the plasma diagnostics, ten additional Thomson scattering channels are providing detailed measurement of the H-mode pedestal and internal barrier regions. The 8 channel MSE diagnostic is providing crucial j(r) measurements including high electron confinement reversed shear plasmas. A tangential microwave scattering system to measure electron-transport- relevant fluctuations is being commissioned.
MHD stability analysis and global mode identification preparing for high beta operation in KSTAR
NASA Astrophysics Data System (ADS)
Park, Y. S.; Sabbagh, S. A.; Berkery, J. W.; Jiang, Y.; Ahn, J. H.; Han, H. S.; Bak, J. G.; Park, B. H.; Jeon, Y. M.; Kim, J.; Hahn, S. H.; Lee, J. H.; Ko, J. S.; in, Y. K.; Yoon, S. W.; Oh, Y. K.; Wang, Z.; Glasser, A. H.
2017-10-01
H-mode plasma operation in KSTAR has surpassed the computed n = 1 ideal no-wall stability limit in discharges exceeding several seconds in duration. The achieved high normalized beta plasmas are presently limited by resistive tearing instabilities rather than global kink/ballooning or RWMs. The ideal and resistive stability of these plasmas is examined by using different physics models. The observed m/ n = 2/1 tearing stability is computed by using the M3D-C1 code, and by the resistive DCON code. The global MHD stability modified by kinetic effects is examined using the MISK code. Results from the analysis explain the stabilization of the plasma above the ideal MHD no-wall limit. Equilibrium reconstructions used include the measured kinetic profiles and MSE data. In preparation for plasma operation at higher beta utilizing the planned second NBI system, three sets of 3D magnetic field sensors have been installed and will be used for RWM active feedback control. To accurately determine the dominant n-component produced by low frequency unstable RWMs, an algorithm has been developed that includes magnetic sensor compensation of the prompt applied field and the field from the induced current on the passive conductors. Supported by US DOE Contracts DE-FG02-99ER54524 and DE-SC0016614.
Armour Materials for the ITER Plasma Facing Components
NASA Astrophysics Data System (ADS)
Barabash, V.; Federici, G.; Matera, R.; Raffray, A. R.; ITER Home Teams,
The selection of the armour materials for the Plasma Facing Components (PFCs) of the International Thermonuclear Experimental Reactor (ITER) is a trade-off between multiple requirements derived from the unique features of a burning fusion plasma environment. The factors that affect the selection come primarily from the requirements of plasma performance (e.g., minimise impurity contamination in the confined plasma), engineering integrity, component lifetime (e.g., withstand thermal stresses, acceptable erosion, etc.) and safety (minimise tritium and radioactive dust inventories). The current selection in ITER is to use beryllium on the first-wall, upper baffle and on the port limiter surfaces, carbon fibre composites near the strike points of the divertor vertical target and tungsten elsewhere in the divertor and lower baffle modules. This paper provides the background for this selection vis-à-vis the operating parameters expected during normal and off-normal conditions. The reasons for the selection of the specific grades of armour materials are also described. The effects of the neutron irradiation on the properties of Be, W and carbon fibre composites at the expected ITER conditions are briefly reviewed. Critical issues are discussed together with the necessary future R&D.
The Radio Plasma Imager Investigation on the IMAGE Spacecraft
NASA Technical Reports Server (NTRS)
Reinisch, Bodo W.; Haines, D. M.; Bibl, K.; Cheney, G.; Galkin, I. A.; Huang, X.; Myers, S. H.; Sales, G. S.; Benson, R. F.; Fung, S. F.
1999-01-01
Radio plasma imaging uses total reflection of electromagnetic waves from plasmas whose plasma frequencies equal the radio sounding frequency and whose electron density gradients are parallel to the wave normals. The Radio Plasma Imager (RPI) has two orthogonal 500-m long dipole antennas in the spin plane for near omni-directional transmission. The third antenna is a 20-m dipole. Echoes from the magnetopause, plasmasphere and cusp will be received with three orthogonal antennas, allowing the determination of their angle-of-arrival. Thus it will be possible to create image fragments of the reflecting density structures. The instrument can execute a large variety of programmable measuring programs operating at frequencies between 3 kHz and 3 MHz. Tuning of the transmit antennas provides optimum power transfer from the 10 W transmitter to the antennas. The instrument can operate in three active sounding modes: (1) remote sounding to probe magnetospheric boundaries, (2) local (relaxation) sounding to probe the local plasma, and (3) whistler stimulation sounding. In addition, there is a passive mode to record natural emissions, and to determine the local electron density and temperature by using a thermal noise spectroscopy technique.
NASA Astrophysics Data System (ADS)
Umstadter, K. R.; Doerner, R.; Tynan, G.
2009-04-01
When an ELM occurs in tokamaks, up to 30% of the pedestal energy can be deposited on the wall of the tokamak causing heating and material loss due to sublimation/evaporation and melt layer splashing of plasma-facing components (PFCs) and expansion of the ejected material into the plasma. A short-pulse laser system capable of reproducing the thermal load of an ELM heat pulse has been integrated into the existing PFC research program in PISCES, a laboratory facility capable of reproducing plasma-materials interactions expected during normal operation of large tokamaks. An Nd:YAG laser capable of delivering up to 1 J of energy over a 7 ns pulsewidth is used for the experiments. Laser heat pulse only, H +/D + plasma only, and laser plus plasma experiments were conducted and initial results indicate enhanced erosion of tungsten exposed to simultaneous plasma and heat pulses, as compared to exposure to separate plasma-only or heat pulse-only conditions.
Realizing Steady State Tokamak Operation for Fusion Energy
NASA Astrophysics Data System (ADS)
Luce, T. C.
2009-11-01
Continuous operation of a tokamak for fusion energy has obvious engineering advantages, but also presents physics challenges beyond the achievement of conditions needed for a burning plasma. The power from fusion reactions and external sources must support both the pressure and the current equilibrium without inductive current drive, leading to demands on stability, confinement, current drive, and plasma-wall interactions that exceed those for pulsed tokamaks. These conditions have been met individually in the present generation of tokamaks, and significant progress has been made in the last decade to realize scenarios where the required conditions are obtained simultaneously. Tokamaks are now operated routinely without disruptions close to the ideal MHD pressure limit, as needed for steady-state operation. Scenarios that project to high fusion gain have been demonstrated where more than half of the current is supplied by the ``bootstrap'' current generated by the pressure gradient in the plasma. Fully noninductive sustainment has been obtained for about a resistive time (the longest intrinsic time scale in the confined plasma) with normalized pressure and confinement approaching those needed for demonstration of steady-state conditions in ITER. One key challenge remaining to be addressed is how to handle the demanding heat and particle fluxes expected in a steady-state tokamak without compromising the high level of core plasma performance. Rather than attempt a comprehensive historical survey, this review will start from the plasma requirements of a steady-state tokamak powerplant, illustrate with examples the progress made in both experimental and theoretical understanding, and point to the remaining physics challenges.
NASA Technical Reports Server (NTRS)
Richardson, R. W.
1974-01-01
The modified Penning discharge in the NASA Lewis Bumpy Torus is normally produced by an anode ring at high voltage in each of the 12 magnetic mirror midplanes. For this investigation, the plasma was run with 12, 6, 3, and 1 anode rings. When 3 anode rings were used, the spectroscopically determined relative electron density and mean ion residence time increased by factors of 10 and 5, respectively, in one mode of operation. The discharge is observed to uniformly fill all bumps around the torus regardless of the anode arrangement and number. A plasma density on axis of 100 billion per cu cm is estimated for the 3-anode case in one mode of operation based on an observed discharge current to ion loss rate correlation and a measured mean ion residence time of .5 msec.
NASA Technical Reports Server (NTRS)
Richardson, R. W.
1974-01-01
The modified Penning discharge in the NASA Lewis Bumpy Torus is normally produced by an anode ring at high voltage in each of the 12 magnetic mirror midplanes. For this investigation, the plasma was run with 12, 6, 3, and 1 anode rings. When 3 anode rings were used, the spectroscopically determined relative electron density and mean ion residence time increase by factors of 10 and 5, respectively, in one mode of operation. The discharge is observed to uniformly fill all bumps around the torus regardless of the anode arrangement and number. A plasma density on axis of 10 to the 11th power cm/3 is estimated for the 3 anode case in one mode of operation based on an observed discharge current to ion loss rate correlation and a measured mean ion residence time of .5 msec.
NASA Astrophysics Data System (ADS)
Mahamud, Rajib; Farouk, Tanvir I.
2015-09-01
Microplasma devices have been the subject of considerable interest and research during the last decade. In a DC system most of the operation regime of the plasma discharges studied fall in the ``abnormal,'' ``normal'' and ``corona'' modes - where a quasi-steady state is achieved. It is well known that even in a DC system the negative differential resistance (NDR) regime can trigger self pulsing discharges. These pulsations are initiated by the parasitic capacitance of the system hence governed by the response time of the power circuit. The circuit response time is required to be larger than the ion transit time to initiate the oscillations. In this present study a suppressor circuit element in the form of an inductor is used to restrain the plasma from switching to a self pulsing mode. It has been identified that the combined response time of the inductor and the plasma discharge (L/Rplasma) has to be larger than the power circuit time constant (RC) to achieve suppression. Inhibition of oscillation has been observed in both experiments and numerical simulations. The obtained voltage-current characteristics show that the inductor element extends the normal glow regime to lower current. Additional parametric simulations are conducted to map out a ``stable'' operation regime. The author would like to thank DARPA (ARO Grant No. W911NF1210007) and University of South Carolina (USC) for the financial support of the work.
NASA Astrophysics Data System (ADS)
Takahashi, H.; Nagaoka, K.; Murakami, S.; Osakabe, M.; Nakano, H.; Ida, K.; Tsujimura, T. I.; Kubo, S.; Kobayashi, T.; Tanaka, K.; Seki, R.; Takeiri, Y.; Yokoyama, M.; Maeta, S.; Nakata, M.; Yoshinuma, M.; Yamada, I.; Yasuhara, R.; Ido, T.; Shimizu, A.; Tsuchiya, H.; Tokuzawa, T.; Goto, M.; Oishi, T.; Morita, S.; Suzuki, C.; Emoto, M.; Tsumori, K.; Ikeda, K.; Kisaki, M.; Shimozuma, T.; Yoshimura, Y.; Igami, H.; Makino, R.; Seki, T.; Kasahara, H.; Saito, K.; Kamio, S.; Nagasaki, K.; Mutoh, T.; Kaneko, O.; Morisaki, T.; the LHD Experiment Group
2017-08-01
A simultaneous high ion temperature (T i) and high electron temperature (T e) regime was successfully extended due to an optimized heating scenario in the LHD. Such high-temperature plasmas were realized by the simultaneous formation of an electron internal transport barrier (ITB) and an ion ITB by the combination of high power NBI and ECRH. Although the ion thermal confinement was degraded in the plasma core with an increase of T e/T i by the on-axis ECRH, it was found that the ion thermal confinement was improved at the plasma edge. The normalized ion thermal diffusivity {χ\\text{i}}/T\\text{i}1.5 at the plasma edge was reduced by 70%. The improvement of the ion thermal confinement at the edge led to an increase in T i in the entire plasma region, even though the core transport was degraded.
Synthetic Microwave Imaging Reflectometry diagnostic using 3D FDTD Simulations
NASA Astrophysics Data System (ADS)
Kruger, Scott; Jenkins, Thomas; Smithe, David; King, Jacob; Nimrod Team Team
2017-10-01
Microwave Imaging Reflectometry (MIR) has become a standard diagnostic for understanding tokamak edge perturbations, including the edge harmonic oscillations in QH mode operation. These long-wavelength perturbations are larger than the normal turbulent fluctuation levels and thus normal analysis of synthetic signals become more difficult. To investigate, we construct a synthetic MIR diagnostic for exploring density fluctuation amplitudes in the tokamak plasma edge by using the three-dimensional, full-wave FDTD code Vorpal. The source microwave beam for the diagnostic is generated and refelected at the cutoff surface that is distorted by 2D density fluctuations in the edge plasma. Synthetic imaging optics at the detector can be used to understand the fluctuation and background density profiles. We apply the diagnostic to understand the fluctuations in edge plasma density during QH-mode activity in the DIII-D tokamak, as modeled by the NIMROD code. This work was funded under DOE Grant Number DE-FC02-08ER54972.
Introduction to the special issue on the technical status of materials for a fusion reactor
NASA Astrophysics Data System (ADS)
Stork, D.; Zinkle, S. J.
2017-09-01
Materials determine in a fundamental way the performance and environmental attractiveness of a fusion reactor: through the size (power fluxes to the divertor, neutron fluxes to the first wall); economics (replacement lifetime of critical in-vessel components, thermodynamic efficiency through operating temperature etc); plasma performance (erosion by plasma fluxes to the divertor surfaces); robustness against off-normal accidents (safety); and the effects of post-operation radioactivity on waste disposal and maintenance. The major philosophies and methodologies used to formulate programmes for the development of fusion materials are outlined, as the basis for other articles in this special issue, which deal with the fundamental understanding of the issues regarding these materials and their technical status and prospects for development.
Pressure and current effects on the thermal efficiency of an MPD arc used as a plasma source
NASA Technical Reports Server (NTRS)
Pivirotto, T. J.
1972-01-01
Measurements of arc voltage and energy loss to the cooled electrodes of a magnetoplasmadynamic (MPD) arc, operating without an applied magnetic field, were made at chamber pressures of 26 to 950 torr, argon mass flow rates of 0.08 to 44 g/s and current of 200 to 2000 A. The resulting arc thermal efficiency varied from 22% at a chamber pressure of 26 torr to 88% at 950 torr. Thermal efficiency was only weakly dependent on arc current. It is concluded that the MPD arc operating without an applied magnetic field and at higher pressure than normally used in thruster applications is a reliable and efficient steady-state plasma source.
Garofalo, Andrea M.; Gong, Xianzu; Grierson, Brian A.; ...
2015-11-16
Recent EAST/DIII-D joint experiments on the high poloidal beta tokamak regime in DIII-D have demonstrated fully noninductive operation with an internal transport barrier (ITB) at large minor radius, at normalized fusion performance increased by ≥30% relative to earlier work. The advancement was enabled by improved understanding of the “relaxation oscillations”, previously attributed to repetitive ITB collapses, and of the fast ion behavior in this regime. It was found that the “relaxation oscillations” are coupled core-edge modes 2 amenable to wall-stabilization, and that fast ion losses which previously dictated a large plasma-wall separation to avoid wall over-heating, can be reduced tomore » classical levels with sufficient plasma density. By using optimized waveforms of the plasma-wall separation and plasma density, fully noninductive plasmas have been sustained for long durations with excellent energy confinement quality, bootstrap fraction ≥ 80%, β N ≤ 4 , β P ≥ 3 , and β T ≥ 2%. Finally, these results bolster the applicability of the high poloidal beta tokamak regime toward the realization of a steady-state fusion reactor.« less
Global modeling of wall material migration following boronization in NSTX-U
NASA Astrophysics Data System (ADS)
Nichols, J. H.; Jaworski, M. A.; Skinner, C. H.; Bedoya, F.; Scotti, F.; Soukhanovskii, V. A.; Schmid, K.
2017-10-01
NSTX-U operated in 2016 with graphite plasma facing components, periodically conditioned with boron to improve plasma performance. Following each boronization, spectroscopic diagnostics generally observed a decrease in oxygen influx from the walls, and an in-vacuo material probe (MAPP) observed a corresponding decrease in surface oxygen concentration at the lower divertor. However, oxygen levels tended to return to a pre-boronization state following repeated plasma exposure. This behavior is interpretively modeled using the WallDYN mixed-material migration code, which couples local erosion and deposition processes with plasma impurity transport in a non-iterative, self-consistent manner that maintains overall material balance. A spatially inhomogenous model of the thin films produced by the boronization process is presented. Plasma backgrounds representative of NSTX-U conditions are reconstructed from a combination of NSTX-U and NSTX datasets. Low-power NSTX-U fiducial discharges, which led to less apparent surface degradation than normal operations, are also modeled with WallDYN. Likely mechanisms driving the observed evolution of surface oxygen are examined, as well as remaining discrepancies between model and experiment and potential improvements to the model. Work supported by US DOE contract DE-AC02-09CH11466.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lumpkin, A. H.; Rule, D. W.; Downer, M. C.
We report the initial considerations of using linearly polarized optical transition radiation (OTR) to characterize the electron beams of laser plasma accelerators (LPAs) such as at the Univ. of Texas at Austin. The two LPAs operate at 100 MeV and 2-GeV, and they currently have estimated normalized emittances at ~ 1-mm mrad regime with beam divergences less than 1/γ and beam sizes to be determined at the micron level. Analytical modeling results indicate the feasibility of using these OTR techniques for the LPA applications.
Plasma Electrolyte Distributions in Humans-Normal or Skewed?
Feldman, Mark; Dickson, Beverly
2017-11-01
It is widely believed that plasma electrolyte levels are normally distributed. Statistical tests and calculations using plasma electrolyte data are often reported based on this assumption of normality. Examples include t tests, analysis of variance, correlations and confidence intervals. The purpose of our study was to determine whether plasma sodium (Na + ), potassium (K + ), chloride (Cl - ) and bicarbonate [Formula: see text] distributions are indeed normally distributed. We analyzed plasma electrolyte data from 237 consecutive adults (137 women and 100 men) who had normal results on a standard basic metabolic panel which included plasma electrolyte measurements. The skewness of each distribution (as a measure of its asymmetry) was compared to the zero skewness of a normal (Gaussian) distribution. The plasma Na + distribution was skewed slightly to the right, but the skew was not significantly different from zero skew. The plasma Cl - distribution was skewed slightly to the left, but again the skew was not significantly different from zero skew. On the contrary, both the plasma K + and [Formula: see text] distributions were significantly skewed to the right (P < 0.01 zero skew). There was also a suggestion from examining frequency distribution curves that K + and [Formula: see text] distributions were bimodal. In adults with a normal basic metabolic panel, plasma potassium and bicarbonate levels are not normally distributed and may be bimodal. Thus, statistical methods to evaluate these 2 plasma electrolytes should be nonparametric tests and not parametric ones that require a normal distribution. Copyright © 2017 Southern Society for Clinical Investigation. Published by Elsevier Inc. All rights reserved.
Inductive flux usage and its optimization in tokamak operation
Luce, Timothy C.; Humphreys, David A.; Jackson, Gary L.; ...
2014-07-30
The energy flow from the poloidal field coils of a tokamak to the electromagnetic and kinetic stored energy of the plasma are considered in the context of optimizing the operation of ITER. The goal is to optimize the flux usage in order to allow the longest possible burn in ITER at the desired conditions to meet the physics objectives (500 MW fusion power with energy gain of 10). A mathematical formulation of the energy flow is derived and applied to experiments in the DIII-D tokamak that simulate the ITER design shape and relevant normalized current and pressure. The rate ofmore » rise of the plasma current was varied, and the fastest stable current rise is found to be the optimum for flux usage in DIII-D. A method to project the results to ITER is formulated. The constraints of the ITER poloidal field coil set yield an optimum at ramp rates slower than the maximum stable rate for plasmas similar to the DIII-D plasmas. Finally, experiments in present-day tokamaks for further optimization of the current rise and validation of the projections are suggested.« less
DNA damage in oral cancer and normal cells induced by nitrogen atmospheric pressure plasma jets
NASA Astrophysics Data System (ADS)
Han, Xu; Kapaldo, James; Liu, Yueying; Stack, M. Sharon; Ptasinska, Sylwia
2015-09-01
Nitrogen atmospheric pressure plasma jets (APPJs) have been shown to effectively induce DNA double strand breaks in SCC25 oral cancer cells. The APPJ source constructed in our laboratory operates based on dielectric barrier discharge. It consists of two copper electrodes alternatively wrapping around a fused silica tube with nitrogen as a feed gas. It is generally more challenging to ignite plasma in N2 atmosphere than in noble gases. However, N2 provides additional advantages such as lower costs compared to noble gases, thus this design can be beneficial for the future long-term clinical use. To compare the effects of plasma on cancer cells (SCC25) and normal cells (OKF), the cells from both types were treated at the same experimental condition for various treatment times. The effective area with different damage levels after the treatment was visualized as 3D maps. The delayed damage effects were also explored by varying the incubation times after the treatment. All of these studies are critical for a better understanding of the damage responses of cellular systems exposed to the plasma radiation, thus are useful for the development of the advanced plasma cancer therapy. The research described herein was supported by the Division of Chemical Sciences, Geosciences and Biosciences, Basic Energy Sciences, Office of Science, United States Department of Energy through Grant No. DE-FC02-04ER15533.
Kugland, Nathan; Doeppner, Tilo; Glenzer, Siegfried; Constantin, Carmen; Niemann, Chris; Neumayer, Paul
2015-04-07
A method is provided for characterizing spectrometric properties (e.g., peak reflectivity, reflection curve width, and Bragg angle offset) of the K.alpha. emission line reflected narrowly off angle of the direct reflection of a bent crystal and in particular of a spherically bent quartz 200 crystal by analyzing the off-angle x-ray emission from a stronger emission line reflected at angles far from normal incidence. The bent quartz crystal can therefore accurately image argon K.alpha. x-rays at near-normal incidence (Bragg angle of approximately 81 degrees). The method is useful for in-situ calibration of instruments employing the crystal as a grating by first operating the crystal as a high throughput focusing monochromator on the Rowland circle at angles far from normal incidence (Bragg angle approximately 68 degrees) to make a reflection curve with the He-like x-rays such as the He-.alpha. emission line observed from a laser-excited plasma.
A dc non-thermal atmospheric-pressure plasma microjet
NASA Astrophysics Data System (ADS)
Zhu, WeiDong; Lopez, Jose L.
2012-06-01
A direct current (dc), non-thermal, atmospheric-pressure plasma microjet is generated with helium/oxygen gas mixture as working gas. The electrical property is characterized as a function of the oxygen concentration and show distinctive regions of operation. Side-on images of the jet were taken to analyze the mode of operation as well as the jet length. A self-pulsed mode is observed before the transition of the discharge to normal glow mode. Optical emission spectroscopy is employed from both end-on and side-on along the jet to analyze the reactive species generated in the plasma. Line emissions from atomic oxygen (at 777.4 nm) and helium (at 706.5 nm) were studied with respect to the oxygen volume percentage in the working gas, flow rate and discharge current. Optical emission intensities of Cu and OH are found to depend heavily on the oxygen concentration in the working gas. Ozone concentration measured in a semi-confined zone in front of the plasma jet is found to be from tens to ˜120 ppm. The results presented here demonstrate potential pathways for the adjustment and tuning of various plasma parameters such as reactive species selectivity and quantities or even ultraviolet emission intensities manipulation in an atmospheric-pressure non-thermal plasma source. The possibilities of fine tuning these plasma species allows for enhanced applications in health and medical related areas.
Li, Hai; Liu, Jianbin; Feng, Xiujuan; Liu, Liehua; Wei, Guohong; Cao, Xiaopei; Li, Yanbing
2017-12-01
To test the efficacy of a strategy based on CT imaging and clinical characteristics on lateralizing origin of excess aldosterone secretion in primary aldosteronism. Consecutive patients with diagnosed primary hyperaldosteronism from June 2006 to July 2012 in our center underwent adrenal surgeries without pre-operational adrenal venous sampling (AVS) if all the three criteria were met: (1) round- or oval-shaped occupational lesion of low density after contrast enhancement with diameter >1 cm on CT scan was located in one adrenal gland; (2) unequivocally normal contralateral adrenal gland; (3) serum potassium level lower than 3.5 mmol/L. Subjects who had received operation were taken into analysis and follow-ups. One hundred and twenty-five patients fulfilled the criteria and were recruited into our research. One hundred and twenty-two operated patients (97.6%) experienced complete resolution of hypokalemia as well as resolution or improvement in hypertension with reduction in antihypertensive medication, while 3 patients (2.4%) failed to obtain normal kalemia and continued on spironolactone therapy. At a median of 65-month (range 21-93) follow-up of these 122 subjects, 27 patients dropped out (22.1%). The 95 responding patients reported no episodes of paralysis or confirmed hypokalemia or any supplementation of potassium. Multivariate linear correlation analysis showed that plasma potassium level was correlated inversely with tumor diameter (r = -0.258, 95% CI -0.076, -0.514, p = 0.037) and basal plasma aldosterone level (r = -0.251, 95% CI -0.040, -0.464, p = 0.042). Most patients with typical unilateral adrenal macroadenomas, normal contralateral glands and hypokalemia could attain favorable surgical therapeutic outcomes without pre-operational AVS lateralization.
Mouse model of plasma cell mastitis.
Yu, Jian-jun; Bao, Shan-lin; Yu, Sheng-lin; Zhang, Da-Qing; Loo, Wings T Y; Chow, Louis W C; Su, Li; Cui, Zhen; Chen, Kai; Ma, Li-Qiong; Zhang, Ning; Yu, Hui; Yang, Yun-Zhen; Dong, Yu; Yip, Adrian Y S; Ng, Elizabeth L Y
2012-09-19
Plasma cell mastitis is distinct from the common form of mastitis and clinically resembles breast carcinoma. The lesion occurs in non-lactating young women, and the incidence rate is rising. Surgical resection is the main treatment, but cannot prevent recurrence of the disease. Disfigurement or removal of breast after the operations can cause marked physical and psychological distress. The etiology of plasma cell mastitis is unclear up till now. It is therefore necessary to investigate further the underlying immunological changes of the disease. The lesions of plasma cell mastitis removed from patients through aseptic operation were mixed with normal saline into homogenate tube machine (homogenate tubes were disinfected and sterilized prior to treatment). The mixture was homogenized at medium speed and grinded in ultrasonic cell disruptor. The homogenate obtained was made into oil emulsion with Freund's adjuvant. Thirty female BALB/c mice (6 weeks after sexual maturity) were divided into five groups A-E: group A was blank control; group B was normal saline control; group C was inoculated with 0.02 ml water-in-oil emulsion; group D was inoculated with 0.04 ml water-in-oil emulsion; group E was complete Freund's adjuvant control. Pathology results showed that mouse mammary gland acinar cells remained integral without any abnormal changes observed in control groups A and B. Experimental groups C and D showed dilation of mouse mammary ductal tissue with a large number of epithelial cells and debris in the lumen, and fibrosis around ducts accompanied by large duct cells, neutrophils, lymphocytes, and especially plasma cell infiltration. Pathological changes were observed in 3 (50%) mice and 5 (83.3%) mice in group C and D respectively. In group E, neutrophil infiltration in mammary gland was observed in 5 mice, but neither infiltration of plasma cells nor other abnormal pathological changes were observed. The lesions of patient with plasma cell mastitis could make the female BALB/c mice experience the similar clinical and pathological manifestation. High-dose group can successfully establish a mouse model of plasma cell mastitis.
NASA Astrophysics Data System (ADS)
Auluck, S. K. H.
2017-11-01
This paper continues earlier discussion [S. K. H. Auluck, Phys. Plasmas 21, 102515 (2014)] concerning the formulation of conservation laws of mass, momentum, and energy in a local curvilinear coordinate system in the dense plasma focus. This formulation makes use of the revised Gratton-Vargas snowplow model [S. K. H. Auluck, Phys. Plasmas 20, 112501 (2013)], which provides an analytically defined imaginary surface in three dimensions which resembles the experimentally determined shape of the plasma. Unit vectors along the local tangent to this surface, along the azimuth, and along the local normal define a right-handed orthogonal local curvilinear coordinate system. The simplifying assumption that physical quantities have significant variation only along the normal enables writing laws of conservation of mass, momentum, and energy in the form of effectively one-dimensional hyperbolic conservation law equations using expressions for various differential operators derived for this coordinate system. This formulation demonstrates the highly non-trivial result that the axial magnetic field and toroidally streaming fast ions, experimentally observed by multiple prestigious laboratories, are natural consequences of conservation of mass, momentum, and energy in the curved geometry of the dense plasma focus current sheath. The present paper continues the discussion in the context of a 3-region shock structure similar to the one experimentally observed: an unperturbed region followed by a hydrodynamic shock containing some current followed by a magnetic piston. Rankine-Hugoniot conditions are derived, and expressions are obtained for the specific volumes and pressures using the mass-flux between the hydrodynamic shock and the magnetic piston and current fraction in the hydrodynamic shock as unknown parameters. For the special case of a magnetic piston that remains continuously in contact with the fluid being pushed, the theory gives closed form algebraic results for the fraction of current flowing in the hydrodynamic shock, specific volume, pressure, and fluid velocity of the hydrodynamic shock region, the tangential, normal, and azimuthal components of velocity in the magnetized plasma, the density of the magnetized plasma, the normal and tangential components of the magnetic field, and the tangential, normal, and azimuthal components of the electric field. This explains the occurrence of azimuthally streaming high energy deuterons experimentally observed by Frascati and Stuttgart. The expression derived for the azimuthal component of vector potential can serve as the basis for a proposed experimental test of the theory.
Okabayashi, M.; Zanca, P.; Strait, E. J.; ...
2016-11-25
Disruptions caused by tearing modes (TMs) are considered to be one of the most critical roadblocks to achieving reliable, steady-state operation of tokamak fusion reactors. We have demonstrated a promising scheme to avoid mode locking by utilizing the electro-magnetic (EM) torque produced with 3D coils that are available in many tokamaks. In this scheme, the EM torque is delivered to the modes by a toroidal phase shift between the externally applied field and the excited TM fields, compensating for the mode momentum loss through the interaction with the resistive wall and uncorrected error fields. Fine control of torque balance ismore » provided by a feedback scheme. We have explored this approach in two widely different devices and plasma conditions: DIII-D and RFX-mod operated in tokamak mode. In DIII-D, the plasma target was high β N in a non-circular divertor tokamak. We define β N as β N = β/(I p /aB t) (%Tm/MA), where β, I p, a, B t are the total stored plasma pressure normalized by the magnetic pressure, plasma current, plasma minor radius and toroidal magnetic field at the plasma center, respectively. The RFX-mod plasma was ohmically-heated with ultra-low safety factor in a circular limiter discharge with active feedback coils outside the thick resistive shell. The DIII-D and RFX-mod experiments showed remarkable consistency with theoretical predictions of torque balance. The application to ignition-oriented devices such as the International Thermonuclear Experimental Reactor (ITER) would expand the horizon of its operational regime. Finally, the internal 3D coil set currently under consideration for edge localized mode suppression in ITER would be well suited for this purpose.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Okabayashi, M.; Zanca, P.; Strait, E. J.
Disruptions caused by tearing modes (TMs) are considered to be one of the most critical roadblocks to achieving reliable, steady-state operation of tokamak fusion reactors. We have demonstrated a promising scheme to avoid mode locking by utilizing the electro-magnetic (EM) torque produced with 3D coils that are available in many tokamaks. In this scheme, the EM torque is delivered to the modes by a toroidal phase shift between the externally applied field and the excited TM fields, compensating for the mode momentum loss through the interaction with the resistive wall and uncorrected error fields. Fine control of torque balance ismore » provided by a feedback scheme. We have explored this approach in two widely different devices and plasma conditions: DIII-D and RFX-mod operated in tokamak mode. In DIII-D, the plasma target was high β N in a non-circular divertor tokamak. We define β N as β N = β/(I p /aB t) (%Tm/MA), where β, I p, a, B t are the total stored plasma pressure normalized by the magnetic pressure, plasma current, plasma minor radius and toroidal magnetic field at the plasma center, respectively. The RFX-mod plasma was ohmically-heated with ultra-low safety factor in a circular limiter discharge with active feedback coils outside the thick resistive shell. The DIII-D and RFX-mod experiments showed remarkable consistency with theoretical predictions of torque balance. The application to ignition-oriented devices such as the International Thermonuclear Experimental Reactor (ITER) would expand the horizon of its operational regime. Finally, the internal 3D coil set currently under consideration for edge localized mode suppression in ITER would be well suited for this purpose.« less
NASA Astrophysics Data System (ADS)
Okabayashi, M.; Zanca, P.; Strait, E. J.; Garofalo, A. M.; Hanson, J. M.; In, Y.; La Haye, R. J.; Marrelli, L.; Martin, P.; Paccagnella, R.; Paz-Soldan, C.; Piovesan, P.; Piron, C.; Piron, L.; Shiraki, D.; Volpe, F. A.; DIII-D, The; RFX-mod Teams
2017-01-01
Disruptions caused by tearing modes (TMs) are considered to be one of the most critical roadblocks to achieving reliable, steady-state operation of tokamak fusion reactors. Here we have demonstrated a promising scheme to avoid mode locking by utilizing the electro-magnetic (EM) torque produced with 3D coils that are available in many tokamaks. In this scheme, the EM torque is delivered to the modes by a toroidal phase shift between the externally applied field and the excited TM fields, compensating for the mode momentum loss through the interaction with the resistive wall and uncorrected error fields. Fine control of torque balance is provided by a feedback scheme. We have explored this approach in two widely different devices and plasma conditions: DIII-D and RFX-mod operated in tokamak mode. In DIII-D, the plasma target was high β N in a non-circular divertor tokamak. Here β N is defined as β N = β/(I p /aB t) (%Tm/MA), where β, I p, a, B t are the total stored plasma pressure normalized by the magnetic pressure, plasma current, plasma minor radius and toroidal magnetic field at the plasma center, respectively. The RFX-mod plasma was ohmically-heated with ultra-low safety factor in a circular limiter discharge with active feedback coils outside the thick resistive shell. The DIII-D and RFX-mod experiments showed remarkable consistency with theoretical predictions of torque balance. The application to ignition-oriented devices such as the International Thermonuclear Experimental Reactor (ITER) would expand the horizon of its operational regime. The internal 3D coil set currently under consideration for edge localized mode suppression in ITER would be well suited for this purpose.
Parks, J S; Li, H; Gebre, A K; Smith, T L; Maeda, N
1995-02-01
Plasma cholesteryl ester (CE) synthesis by lecithin cholesterol acyltransferase (LCAT) is activated by apolipoprotein (apo)A-I. We studied the effect of plasma apoA-I concentration on LCAT activation, using normal, heterozygous or homozygous apoA-I-deficient mice made by gene targeting. Plasma esterified cholesterol concentrations of mice fed chow diets were ordered (mean +/- SEM): 105 +/- 7 (normal) > 70 +/- 5 (heterozygotes) > 26 +/- 2 (homozygotes) mg/dl. Plasma free cholesterol concentrations were similar among the three genotypes. Endogenous LCAT activity, measured as the decrease in plasma free cholesterol after a 1 h incubation at 37 degrees C, was ordered: 44 +/- 3 (normal) > 21 +/- 2 (heterozygotes) > 5 +/- 1 (homozygotes) nmol CE formed/h per ml plasma. Using a recombinant exogenous substrate consisting of egg yolk phospholipid, [14C]cholesterol, and apoA-I, CE formation of normals and heterozygotes was similar (27.4 +/- 0.6 and 28.8 +/- 1.3 nmol/h per ml plasma, respectively), but was significantly less for homozygotes (19.2 +/- 1.7 nmol/h per ml plasma). However, using a small unilamellar vesicle substrate particle containing phospholipid and [14C]cholesterol, CE formation was ordered: 1.6 +/- 0.1 (normal) = 1.6 +/- 0.1 (heterozygotes) > 0.6 +/- 0.1 (homozygotes) nmol/h per ml plasma; addition of apoA-I to the plasma of homozygous animals restored CE formation to normal levels (1.6 +/- 0.1). CE fatty acid analysis demonstrated that plasma from homozygous mice contained significantly more saturated and monounsaturated and fewer polyunsaturated fatty acids compared to normal and heterozygous mice.(ABSTRACT TRUNCATED AT 250 WORDS)
Sainsbury, A; Herzog, H
2001-03-01
Neuropeptide Y (NPY) in the hypothalamus exerts multiple physiological functions including stimulation of adipogenic pathways such as feeding and insulin secretion as well as inhibition of the somatotropic and gonadotropic axes. Since hypothalamic NPY-ergic activity is increased by negative energy balance, NPY enables coordinated regulation of growth and reproduction in parallel with energy availability. Chronic pathological increases in central NPY-ergic activity contribute to obesity. Many of the adipogenic effects of NPY are specifically dependent on adrenal glucocorticoids. However, in the current study we show that central NPY does not require adrenal hormones to inhibit the somatotropic and gonadotropic axes in rats. Male adrenalectomized and sham-operated normal rats were intracerebroventricularly (ICV) infused with NPY (15 microg/day) or saline for 5-7 days, and plasma leptin, insulin-like growth factor (IGF-1) and testosterone were assayed, and epididymal white adipose tissue (WATe) was weighed. In normal intact rats, WATe weight and leptinemia were significantly increased by NPY, and these effects were prevented by adrenalectomy. In normal rats, NPY markedly reduced plasma IGF-1 levels (470 +/- 40 versus 1260 +/- 90 ng/ml) and testosterone (0.53 +/- 0.28 versus 5.4 +/- 0.80 nmol/l in saline-infused controls, p < 0.0001). Adrenalectomy decreased plasma IGF-1 concentrations to 290 +/- 30 (p < 0.0001 versus normal rats), which were significantly reduced further by NPY. However, adrenalectomy had no significant effect on basal nor on NPY-induced plasma testosterone concentrations. In conclusion unlike the stimulatory effects of NPY on fat mass and leptinemia, NPY-induced inhibition of the somatotropic and gonadotropic axes in male rats do not require adrenal hormones.
Design And Testing of The Floating Potential Probe For ISS
NASA Technical Reports Server (NTRS)
Hillard, G. Barry; Ferguson, Dale C.
2001-01-01
Flight 4A was an especially critical mission for the International Space Station (ISS). For the first time, the high voltage solar arrays generated significant amounts of power and long predicted environmental interactions (high negative floating potential and concomitant dielectric charging) became serious concerns. Furthermore, the same flight saw the Plasma Contacting Unit (PCU) deployed and put into operation to mitigate and control these effects. The ISS program office has recognized the critical need to verify, by direct measurement, that ISS does not charge to unacceptable levels. A Floating Potential Probe (FPP) was therefore deployed on ISS to measure ISS floating potential relative to the surrounding plasma and to measure relevant plasma parameters. The primary objective of FPP is to verify that ISS floating potential does not exceed the specified level of 40 volts with respect to the ambient. Since it is expected that in normal operations the PCU will maintain ISS within this specification, it is equivalent to say that the objective of FPP is to monitor the functionality of the PCU. In this paper, we report on the design and testing of the ISS FPP. In a separate paper, the operations and results obtained so far by the FPP will be presented.
Extending the physics basis of quiescent H-mode toward ITER relevant parameters
Solomon, W. M.; Burrell, K. H.; Fenstermacher, M. E.; ...
2015-06-26
Recent experiments on DIII-D have addressed several long-standing issues needed to establish quiescent H-mode (QH-mode) as a viable operating scenario for ITER. In the past, QH-mode was associated with low density operation, but has now been extended to high normalized densities compatible with operation envisioned for ITER. Through the use of strong shaping, QH-mode plasmas have been maintained at high densities, both absolute (more » $$\\bar{n}$$ e ≈ 7 × 10 19 m ₋3) and normalized Greenwald fraction ($$\\bar{n}$$ e/n G > 0.7). In these plasmas, the pedestal can evolve to very high pressure and edge current as the density is increased. High density QH-mode operation with strong shaping has allowed access to a previously predicted regime of very high pedestal dubbed “Super H-mode”. Calculations of the pedestal height and width from the EPED model are quantitatively consistent with the experimentally observed density evolution. The confirmation of the shape dependence of the maximum density threshold for QH-mode helps validate the underlying theoretical model of peeling- ballooning modes for ELM stability. In general, QH-mode is found to achieve ELM- stable operation while maintaining adequate impurity exhaust, due to the enhanced impurity transport from an edge harmonic oscillation, thought to be a saturated kink- peeling mode driven by rotation shear. In addition, the impurity confinement time is not affected by rotation, even though the energy confinement time and measured E×B shear are observed to increase at low toroidal rotation. Together with demonstrations of high beta, high confinement and low q 95 for many energy confinement times, these results suggest QH-mode as a potentially attractive operating scenario for the ITER Q=10 mission.« less
NASA Astrophysics Data System (ADS)
Reece Roth, J.
2004-11-01
The majority of industrial plasma processing with glow discharges has been conducted at pressures below 10 torr. This tends to limit applications to high value workpieces as a result of the high capital cost of vacuum systems and the production constraints of batch processing. It has long been recognized that glow discharge plasmas would play a much larger industrial role if they could be generated at one atmosphere. The One Atmosphere Uniform Glow Discharge Plasma (OAUGDP), developed at the University of Tennessee's Plasma Sciences Laboratory, is a non-thermal RF plasma operating on displacement currents with the time-resolved characteristics of a classical low pressure DC normal glow discharge. As a glow discharge, the OAUGDP operates with maximum electrical efficiency at the Stoletow point, where the energy input per ion-electron pair is a minimum [1, 2]. Several interdisciplinary teams have investigated potential applications of the OAUGDP. These teams included collaborators from the UTK Textiles and Nonwovens Development Center (TANDEC), and the Departments of Electrical and Computer Engineering, Microbiology, and Food Science and Technology, as well as the NASA Langley Research Center. The potential applications of the OAUGDP have all been at one atmosphere and room temperature, using air as the working gas. These applications include sterilizing medical and dental equipment; sterilizable air filters to deal with the "sick building syndrome"; removal of soot from Diesel engine exhaust; subsonic plasma aerodynamic effects, including flow re-attachment to airfoils and boundary layer modification; electrohydrodynamic (EDH) flow control of working gases; increasing the surface energy of materials; improving the adhesion of paints and electroplated layers: improving the wettability and wickability of fabrics; stripping of photoresist; and plasma deposition and directional etching of potential microelectronic relevance. [1] J. R. Roth, Industrial Plasma Engineering: Volume I, Principles. Institute of Physics Publishing, Bristol and Philadelphia 1995, ISBN 0-7503-0318-2. [2] Roth, J. R. Industrial Plasma Engineering: Volume II Applications to Nonthermal Plasma Processing Institute of Physics Publishing, Bristol and Philadelphia. 2001, ISBN 0-7503-0545-2.
Hensel, Karol; Kučerová, Katarína; Tarabová, Barbora; Janda, Mário; Machala, Zdenko; Sano, Kaori; Mihai, Cosmin Teodor; Ciorpac, Mitică; Gorgan, Lucian Dragos; Jijie, Roxana; Pohoata, Valentin; Topala, Ionut
2015-06-06
Atmospheric pressure DC-driven self-pulsing transient spark (TS) discharge operated in air and pulse-driven dielectric barrier discharge plasma jet (PJ) operated in helium in contact with water solutions were used for inducing chemical effects in water solutions, and the treatment of bacteria (Escherichia coli), mammalian cells (Vero line normal cells, HeLa line cancerous cells), deoxyribonucleic acid (dsDNA), and protein (bovine serum albumin). Two different methods of water solution supply were used in the TS: water electrode system and water spray system. The effects of both TS systems and the PJ were compared, as well as a direct exposure of the solution to the discharge with an indirect exposure to the discharge activated gas flow. The chemical analysis of water solutions was performed by using colorimetric methods of UV-VIS absorption spectrophotometry. The bactericidal effects of the discharges on bacteria were evaluated by standard microbiological plate count method. Viability, apoptosis and cell cycle were assessed in normal and cancerous cells. Viability of cells was evaluated by trypan blue exclusion test, apoptosis by Annexin V-FITC/propidium iodide assay, and cell cycle progression by propidium iodide/RNase test. The effect of the discharges on deoxyribonucleic acid and protein were evaluated by fluorescence and UV absorption spectroscopy. The results of bacterial and mammalian cell viability, apoptosis, and cell cycle clearly show that cold plasma can inactivate bacteria and selectively target cancerous cells, which is very important for possible future development of new plasma therapeutic strategies in biomedicine. The authors found that all investigated bio-effects were stronger with the air TS discharge than with the He PJ, even in indirect exposure.
NASA Astrophysics Data System (ADS)
O'Connell, Deborah; Hirst, A. M.; Packer, J. R.; Simms, M. S.; Mann, V. M.; Frame, F. M.; Maitland, N. J.
2016-09-01
Atmospheric pressure plasmas have shown considerable promise as a potential cancer therapy. An atmospheric pressure plasma driven with kHz kV excitation, operated with helium and oxygen admixtures is used to investigate the interaction with prostate cancer cells. The cytopathic effect was verified first in two commonly used prostate cancer cell lines (BPH-1 and PC-3 cells) and further extended to examine the effects in paired normal and tumour prostate epithelial cells cultured directly from patient tissues. Through the formation of reactive species in cell culture media, and potentially other plasma components, we observed high levels of DNA damage, together with reduced cell viability and colony-forming ability. We observed differences in response between the prostate cell lines and primary cells, particularly in terms of the mechanism of cell death. The primary cells ultimately undergo necrotic cell death in both the normal and tumour samples, in the complete absence of apoptosis. In addition, we provide the first evidence of an autophagic response in primary cells. This work highlights the importance of studying primary cultures in order to gain a more realistic insight into patient efficacy. EPSRC EP/H003797/1 & EP/K018388/1, Yorkshire Cancer Research: YCR Y257PA.
Effects of high Z probe on plasma behavior in HT-6M tokamak
NASA Astrophysics Data System (ADS)
Li, J.; Gong, X.; Luo, L.; Yin, F. X.; Noda, N.; Wan, B.; Xu, W.; Gao, X.; Yin, F.; Jiang, J. G.; Wu, Z.; Zhao, J. Y.; Wu, M.; Liu, S.; Han, Y.
1997-02-01
Molybdenum and tungsten probes have been tested in HT-6M tokamak under various discharge conditions aiming to find out the conditions in which high Z PFC can be used without serious degradation of core plasma performance. In normal OH discharges, the degradation of core plasma performance was found only when the probe was inserted beyond 3.0 cm inside the last closed flux surface (LCFS). The plasma performance did not change with positive biasing to the probe, whereas central Te degraded during negative biasing of -100 V. The insertion of the Mo probe to 1.5 cm inside the LCFS made a change in the threshold power of the L-H transition in EOH discharges. These results suggest a certain operation range of the H-mode in the EOH discharge with the Mo probe in HT-6M.
MHD limits and plasma response in high-beta hybrid operations in ASDEX Upgrade
NASA Astrophysics Data System (ADS)
Igochine, V.; Piovesan, P.; Classen, I. G. J.; Dunne, M.; Gude, A.; Lauber, P.; Liu, Y.; Maraschek, M.; Marrelli, L.; McDermott, R.; Reich, M.; Ryan, D.; Schneller, M.; Strumberger, E.; Suttrop, W.; Tardini, G.; Zohm, H.; The ASDEX Upgrade Team; The EUROfusion MST1 Team
2017-11-01
The improved H-mode scenario (or high β hybrid operations) is one of the main candidates for high-fusion performance tokamak operation that offers a potential steady-state scenario. In this case, the normalized pressure {{β }N} must be maximized and pressure-driven instabilities will limit the plasma performance. These instabilities could have either resistive ((m = 2, n = 1) and (3,2) neoclassical tearing modes (NTMs)) or ideal character (n = 1 ideal kink mode). In ASDEX Upgrade (AUG), the first limit for maximum achievable {{β }N} is set by the NTMs. The application of pre-emptive electron cyclotron current drive at the q = 2 and q = 1.5 resonant surfaces reduces this problem, so that higher values of {{β }N} can be reached. AUG experiments have shown that, in spite of the fact that hybrids are mainly limited by NTMs, the proximity to the no-wall limit leads to amplification of the external fields that strongly influence the plasma profiles. For example, rotation braking is observed throughout the plasma and peaks in the core. In this situation, even small external fields are amplified and their effect becomes visible. To quantify these effects, the plasma response to the magnetic fields produced by B-coils is measured as {{β }N} approaches the no-wall limit. These experiments and corresponding modeling allow the identification of the main limiting factors, which depend on the stabilizing influence of the conducting components facing the plasma surface, the existence of external actuators, and the kinetic interaction between the plasma and the marginally stable ideal modes. Analysis of the plasma reaction to external perturbations allowed us to identify optimal correction currents for compensating the intrinsic error field in the device. Such correction, together with the analysis of kinetic effects, will help to increase {{β }N} further in future experiments.
DOE Office of Scientific and Technical Information (OSTI.GOV)
McGoldrick, P.R.
1981-01-01
The Mirror Fusion Test Facility (MFTF) is a complex facility requiring a highly-computerized Supervisory Control and Diagnostics System (SCDS) to monitor and provide control over ten subsystems; three of which require true process control. SCDS will provide physicists with a method of studying machine and plasma behavior by acquiring and processing up to four megabytes of plasma diagnostic information every five minutes. A high degree of availability and throughput is provided by a distributed computer system (nine 32-bit minicomputers on shared memory). Data, distributed across SCDS, is managed by a high-bandwidth Distributed Database Management System. The MFTF operators' control roommore » consoles use color television monitors with touch sensitive screens; this is a totally new approach. The method of handling deviations to normal machine operation and how the operator should be notified and assisted in the resolution of problems has been studied and a system designed.« less
Deno, D C; McCafferty, M H; Saba, T M; Blumenstock, F A
1984-01-01
Plasma fibronectin was depleted within 15 min following sublethal burn, followed by partial recovery at 8 h and complete restoration by 24 h in anesthetized rats. Radiolabeled 75Se-plasma fibronectin, injected intravenously before burn, was rapidly sequestered in burn skin as well as the liver. Fibronectin levels at 2 h postburn as detected by immunoassay vs. 75Se-plasma fibronectin indicated that more fibronectin was in the plasma than detected by electroimmunoassay. Crossed immunoelectrophoretic analysis of fibronectin in early postburn plasma demonstrated a reduced electrophoretic mobility of the fibronectin antigen. Addition of heparin or fibrin, both of which have affinity for fibronectin, to normal plasma was unable to reproduce this altered fibronectin electrophoretic pattern. In contrast, addition of gelatin or native collagen to normal plasma reproduced the abnormal electrophoretic pattern of fibronectin seen in burn plasma. Extracts of burned skin, but not extracts of normal skin, when added to normal plasma, elicited a similar altered electrophoretic pattern for fibronectin. By gel filtration, fibronectin in burn plasma had an apparent molecular weight approximately 40% greater than that observed in normal plasma. These data suggest the release into the blood of a gelatinlike ligand from burned skin, which complexes with plasma fibronectin. Thus, fibronectin deficiency acutely postburn appears mediated by (a) its accumulation at the site of burn injury; (b) its removal from the circulation by the liver; and (c) its presence in the plasma in a form that is less detectable by immunoassay. Images PMID:6690478
Materials characterization of impregnated W and W-Ir cathodes after oxygen poisoning
NASA Astrophysics Data System (ADS)
Polk, James E.; Capece, Angela M.
2015-05-01
Electric thrusters use hollow cathodes as the electron source for generating the plasma discharge and for beam neutralization. These cathodes contain porous tungsten emitters impregnated with BaO material to achieve a lower surface work function and are operated with xenon propellant. Oxygen contaminants in the xenon plasma can poison the emitter surface, resulting in a higher work function and increased operating temperature. This could lead directly to cathode failure by preventing discharge ignition or could accelerate evaporation of the BaO material. Exposures over hundreds of hours to very high levels of oxygen can result in increased temperatures, oxidation of the tungsten substrate, and the formation of surface layers of barium tungstates. In this work, we present results of a cathode test in which impregnated tungsten and tungsten-iridium emitters were operated with 100 ppm of oxygen in the xenon plasma for several hundred hours. The chemical and morphological changes were studied using scanning electron microscopy, energy dispersive spectroscopy, and laser profilometry. The results provide strong evidence that high concentrations of oxygen accelerate the formation of tungstate layers in both types of emitters, a phenomenon not inherent to normal cathode operation. Deposits of pure tungsten were observed on the W-Ir emitter, indicating that tungsten is preferentially removed from the surface and transported in the insert plasma. A W-Ir cathode surface will therefore evolve to a pure W composition, eliminating the work function benefit of W-Ir. However, the W-Ir emitter exhibited less erosion and redeposition at the upstream end than the pure W emitter.
Zhao, Yang; Zheng, Zhi-Nan; Pi, Yan-Na; Liang, Xue; Jin, San-Qing
2017-01-01
A previous study in our laboratory demonstrated that transfusion of plasma collected at the late phase of remote ischemic preconditioning (RIPC) could reduce myocardial infarct size. Here, we tested whether the reperfusion injury salvage kinase (RISK) and survivor activating factor enhancement (SAFE) pathways are involved in transferring protection. In a two-part study, donor rats ( n = 3) donated plasma 48 hours after RIPC (preconditioned plasma) or control (nonpreconditioned plasma). Normal (part 1) or ischemic (part 2) myocardia were collected from recipients ( n = 6) 24 hours after receiving normal saline, nonpreconditioned plasma, and preconditioned plasma or after further suffering ischemia reperfusion. Western blot was performed to analyze STAT3, Akt, and Erk1/2 phosphorylation in normal and ischemic myocardium (central area and border area). In normal myocardia, preconditioned plasma increased Akt and Erk1/2 phosphorylation significantly compared to nonpreconditioned plasma and normal saline; no STAT3 phosphorylation was detected. In ischemic myocardia, preconditioned plasma increased Akt and Erk1/2 phosphorylation significantly in both central and border areas compared to other fluids; no significant difference in STAT3 phosphorylation occurred among groups. Transfusion of preconditioned plasma collected at the late phase of RIPC could activate the RISK but not SAFE pathway, suggesting that RISK pathway may be involved in transferring protection.
He-3-rich flares - A possible explanation
NASA Technical Reports Server (NTRS)
Fisk, L. A.
1978-01-01
A plasma mechanism is proposed to explain the dramatic enhancements in He-3 observed in He-3-rich flares. It is shown that a common current instability in the corona may heat ambient He-3(2+) over any other ion and thus may preferentially inject He-3 into the flare acceleration process. This mechanism operates when the abundance of He-4 and heavier elements is larger than normal in the coronal plasma. It may also preferentially heat and thus inject certain ions of iron. The mechanism thus provides a possible explanation for the observed correlation between He-3 and heavy enhancements in He-3-rich flares.
Sensitivity Analysis of the Off-Normal Conditions of the SPIDER Accelerator
DOE Office of Scientific and Technical Information (OSTI.GOV)
Veltri, P.; Agostinetti, P.; Antoni, V.
2011-09-26
In the context of the development of the 1 MV neutral beam injector for the ITER tokamak, the study on beam formation and acceleration has considerable importance. This effort includes the ion source and accelerator SPIDER (Source for Production of Ions of Deuterium Extracted from an Rf plasma) ion source, planned to be built in Padova, and designed to extract and accelerate a 355 A/m{sup 2} current of H{sup -}(or 285 A/m{sup 2} D{sup -}) up to 100 kV. Exhaustive simulations were already carried out during the accelerator optimization leading to the present design. However, as it is expected thatmore » the accelerator shall operate also in case of pre-programmed or undesired off-normal conditions, the investigation of a large set of off-normal scenarios is necessary. These analyses will also be useful for the evaluation of the real performances of the machine, and should help in interpreting experimental results, or in identifying dangerous operating conditions.The present contribution offers an overview of the results obtained during the investigation of these off-normal conditions, by means of different modeling tools and codes. The results, showed a good flexibility of the device in different operating conditions. Where the consequences of the abnormalities appeared to be problematic further analysis were addressed.« less
Boehnke, M; Moll, P P; Kottke, B A; Weidman, W H
1987-04-01
Fasting plasma glucose measurements made in 1972-1977 on normoglycemic individuals in three-generation Caucasian pedigrees from Rochester, Minnesota were analyzed. The authors determined the contributions of polygenic loci and environmental factors to fasting plasma glucose variability in these pedigrees. To that end, fasting plasma glucose measurements were normalized by an inverse normal scores transformation and then regressed separately for males and females on measured concomitants including age, body mass index (weight/height2), season of measurement, sex hormone use, and diuretic use. The authors found that 27.7% of the variability in normalized fasting plasma glucose in these pedigrees is explained by these measured concomitants. Subsequent variance components analysis suggested that unmeasured polygenic loci and unmeasured shared environmental factors together account for at least an additional 36.7% of the variability in normalized fasting plasma glucose, with genes alone accounting for at least 27.3%. These results are consistent with the known familiality of diabetes, for which fasting plasma glucose level is an important predictor. Further, these familial factors provide an explanation for at least half the variability in normalized fasting plasma glucose which remains after regression on known concomitants.
Success and failure of the plasma analogy for Laughlin states on a torus
NASA Astrophysics Data System (ADS)
Fremling, Mikael
2017-01-01
We investigate the nature of the plasma analogy for the Laughlin wave function on a torus describing the quantum Hall plateau at ν =\\frac{1}{q} . We first establish, as expected, that the plasma is screening if there are no short nontrivial paths around the torus. We also find that when one of the handles has a short circumference—i.e. the thin-torus limit—the plasma no longer screens. To quantify this we compute the normalization of the Laughlin state, both numerically and analytically. In the thin torus limit, the analytical form of the normalization simplify and we can reconstruct the normalization and analytically extend it back into the 2D regime. We find that there are geometry dependent corrections to the normalization, and this in turn implies that the plasma in the plasma analogy is not screening when in the thin torus limit. Despite the breaking of the plasma analogy in this limit, the analytical approximation is still a good description of the normalization for all tori, and also allows us to compute hall viscosity at intermediate thickness.
Circular RNA hsa_circ_0000745 may serve as a diagnostic marker for gastric cancer.
Huang, Mei; He, Yi-Ren; Liang, Li-Chuan; Huang, Qiang; Zhu, Zhi-Qiang
2017-09-14
To determine whether circular RNAs (circRNAs) are involved in pathological processes of gastric cancer (GC). Three circRNAs with differential expression in GC and colorectal cancer were randomly selected for validation by quantitative reverse transcription-polymerase chain reaction (qRT-PCR), using 20 pairs of gastric tissues and normal tissues. Based on the predicted circRNA-miRNA network, we then focused on hsa_circ_0000745, which was found to be down-regulated in 20 GC tissues compared with normal tissues. The hsa_circ_0000745 levels were further analyzed by qRT-PCR in 60 GC tissues and paired adjacent non-tumor tissues, as well as 60 plasma samples from GC patients and 60 plasma samples from healthy controls. The associations between the levels of hsa_circ_0000745 and the clinicopathological features of GC patients were statistically assessed. A receiver operating characteristic (ROC) curve was used to evaluate the diagnostic value of hsa_circ_0000745 in GC. Hsa_circ_0000745 was down-regulated in GC tissues vs non-tumorous tissues ( P < 0.001) and in plasma samples from patients with GC vs healthy controls ( P < 0.001). The expression level of hsa_circ_0000745 in GC tissues correlated with tumor differentiation, while the expression level in plasma correlated with tumor-node-metastasis stage. The area under the ROC curve (AUC) of hsa_circ_0000745 in plasma was 0.683, suggesting good diagnostic value. Plasma hsa_circ_0000745 level combined with carcinoembryogenic antigen (CEA) level increased the AUC to 0.775. Hsa_circ_0000745 plays an important role in GC and its expression level in plasma in combination with CEA level is a promising diagnostic marker for this malignancy.
DOE Office of Scientific and Technical Information (OSTI.GOV)
McKenzie-Carter, M.A.; Lyon, R.E.; Rope, S.K.
This report contains information to support the Environmental Assessment for the Burning Plasma Experiment (BPX) Project proposed for the Princeton Plasma Physics Laboratory (PPPL). The assumptions and methodology used to assess the impact to members of the public from operational and accidental releases of radioactive material from the proposed BPX during the operational period of the project are described. A description of the tracer release tests conducted at PPPL by NOAA is included; dispersion values from these tests are used in the dose calculations. Radiological releases, doses, and resulting health risks are calculated and summarized. The computer code AIRDOS- EPA,more » which is part of the computer code system CAP-88, is used to calculate the individual and population doses for routine releases; FUSCRAC3 is used to calculate doses resulting from off-normal releases where direct application of the NOAA tracer test data is not practical. Where applicable, doses are compared to regulatory limits and guideline values. 48 refs., 16 tabs.« less
Grainick, H R; Williams, S B; McKeown, L P; Rick, M E; Maisonneuve, P; Jenneau, C; Sultan, Y
1985-01-01
We have investigated and characterized the abnormalities in four unrelated patients with von Willebrand's disease (vWd) who have (a) enhanced ristocetin-induced platelet aggregation (RIPA) at low ristocetin concentrations, (b) absence of the largest plasma von Willebrand factor (vWf) multimers, and (c) thrombocytopenia. The platelet-rich plasma of these patients aggregates spontaneously without the addition of any agonists. When isolated normal platelets are resuspended in patient plasma spontaneous aggregation occurs; however, the patients' plasmas did not induce platelet aggregation of normal washed formalinized platelets. When the patients' platelets are suspended in normal plasma, spontaneous aggregation is not observed. The spontaneous platelet aggregation (SPA) is associated with dense granule secretion as measured by ATP release and alpha granule release as measured by beta-thromboglobulin and platelet factor 4 release. The SPA is totally inhibited by 5 mM EDTA, prostaglandin I2, and dibutryl cyclic AMP, while it is only partially inhibited by 1 mM EDTA, acetylsalicylic acid, or apyrase. A monoclonal antibody directed against glycoprotein Ib (GPIb) and/or a monoclonal antibody against the glycoprotein IIb/IIIa (GPIIb/IIIa) complex totally inhibits the SPA. The vWf was isolated from the plasma of one of these patients. The purified vWf induced platelet aggregation of normal platelets resuspended in either normal or severe vWd plasma, but the vWf did not induce platelet aggregation of normal platelets resuspended in afibrinognemic plasma. Sialic acid and galactose quantification of the patient's vWf revealed approximately a 50% reduction compared with normal vWf. These studies indicate that a form of vWd exists, which is characterized by SPA that is induced by the abnormal plasma vWf. The SPA is dependent on the presence of plasma fibrinogen, and the availability of the GPIb and the GPIIb/IIIa complex. In this variant form of vWd the abnormal vWf causes enhanced RIPA, SPA, and thrombocytopenia. Images PMID:2932469
Experimental Results of OH Regime Investigation in Globus-M Spherical Torus
NASA Astrophysics Data System (ADS)
Golant, Victor; Gusev, Vasily; Levin, Roman; Petrov, Yuriy; Sakharov, Nikolay
2001-10-01
Plasma parameters were measured in novel spherical torus Globus-M in highly shaped plasmas with aspect ratio, A > 1.5, elongation, k < 1.9, triangularity < 0.5. Plasma column was created by direct induction method with the currents up to Ip 0.3 MA in the magnetic field, Bt - 0.08 - 0.5 T. In Globus-M spherical torus plasma column is closely fitted into the vacuum vessel and wall conditioning technology described in [1] was used to achieve good plasma performance. Plasma experiments were focused around achievement of ultimate OH regimes allowed by power supplies. The operational limits of the device were investigated. In the regime with extreme low q(cy1) < 1 and high normalized current > 4, the plasma current of almost 100kA was sustained transiently in low magnetic field 800 Gs. The first results on stability analysis with numerical code are presented. The runaway electrons behavior was studied in spherical tokamak conditions. Influence of plasma current and density ramp-up speeds, MHD events on plasma performance and stability was demonstrated. Magnetic reconstruction was performed with EFIT version adopted for PC simulations. Plans for auxiliary heating and current drive are discussed. 1. V.K. Gusev, …, V.E. Golant, et al., Nucl. Fusion 41, No 7, (2001), to be published
David, Louis; Anast, Constantine S.
1974-01-01
Serum immunoreactive parathyroid hormone (iPTH) and plasma total calcium, ionized calcium, magnesium, and phosphorus levels were determined during the first 9 days of life in 137 normal term infants, 55 “sick” infants, and 43 hypocalcemic (Ca <7.5 mg/100 ml; Ca++<4.0 mg/100 ml) infants. In the cord blood, elevated levels of plasma Ca++ and Ca were observed, while levels of serum iPTH were either undetectable or low. In normal newborns during the first 48 h of life there was a decrease in plasma Ca and Ca++, while the serum iPTH level in most samples remained undetectable or low; after 48 h there were parallel increases in plasma Ca and Ca++ and serum iPTH levels. Plasma Mg and P levels increased progressively after birth in normal infants. In the sick infants, plasma Ca, Ca++ and P levels were significantly lower than in the normal newborns, while no significant differences were found in the plasma Mg levels. The general pattern of serum iPTH levels in the sick infants was similar to that observed in the normal group, though there was a tendency for the increase in serum iPTH to occur earlier and for the iPTH levels to be higher in the sick infants. In the hypocalcemic infants, plasma Mg levels were consistently lower than in the normal infants after 24 h of age, while no significant differences were found in the plasma P levels. Hyperphosphatemia was uncommon and did not appear to be a contributing factor in the pathogenesis of hypocalcemia in most infants. Most of the hypocalcemic infants, including those older than 48 h, had inappropriately low serum iPTH levels. Evidence obtained from these studies indicates that parathyroid secretion is normally low in the early new born period and impaired parathyroid function, characterized by undetectable or low serum iPTH, is present in most infants with neonatal hypocalcemia. Additional unknown factors appear to contribute to the lowering of plasma Ca in the neonatal period. The net effect of unknown plasma hypocalcemic factor(s) on the one hand and parathyroid activity on the other may account for differences in plasma Ca levels observed between normal, sick, and hypocalcemic infants. Depressed plasma Mg is frequently present in hypocalcemic infants. To what degree the hypomagnesemia reflects parathyroid insufficiency or the converse, to what degree parathyroid insufficiency and hypocalcemia are secondary to hypomagnesemia, is uncertain. PMID:4858778
Comprehensive Study of Plasma-Wall Sheath Transport Phenomena
2012-09-10
environment, a Langmuir probe and a Retarding Potential Analyzer (RPA). The Langmuir probe could be considered the seminal plasma diagnostic, and a large...plasma-sheath interface. Electric field is normalized by Te/LD (LD is the Debye length) and velocity is normalized by the Bohm speed. Figure 14...studying the interaction of the near-wall plasma sheath with a magnetic field , and modeled the plasma sheath of the GT thick-sheath (~10mm) plasma
NASA Astrophysics Data System (ADS)
Dubin, D. H. E.
This chapter explores several aspects of the linear electrostatic normal modes of oscillation for a single-species non-neutral plasma in a Penning trap. Linearized fluid equations of motion are developed, assuming the plasma is cold but collisionless, which allow derivation of the cold plasma dielectric tensor and the electrostatic wave equation. Upper hybrid and magnetized plasma waves in an infinite uniform plasma are described. The effect of the plasma surface in a bounded plasma system is considered, and the properties of surface plasma waves are characterized. The normal modes of a cylindrical plasma column are discussed, and finally, modes of spheroidal plasmas, and finite temperature effects on the modes, are briefly described.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ding, S.; Xu, G. S.; Wang, Q.
A recent experiment on DIII-D, which was conducted by the joint research team from DIII-D and EAST, has extended the previous high β p, high q min regime, which has been tested in the 2013 DIII-D/EAST joint experiment, to inductive operation at higher plasma current (I p=0.8 MA) and significantly higher normalized fusion performance (G = H 89β N/=qmore » $$2\\atop{95}$$ = 0.16). The experiment aims at exploring high performance scenario with q min > 2 and reduced torque for long pulse operation, which can be potentially extrapolated to EAST. The effort was largely motivated by the interest in developing a feasible scenario for long-pulse high performance operation with low torque on EAST. Very high confinement, H 89 = 3.5 or H 98,y2 = 2.1 with β N ~ 3.0, has been achieved transiently in this experiment together with q min > 2 and reduced NBI torque (3~5 N-m). The excellent confinement is associated with the spontaneous formation of an internal transport barrier (ITB) in plasmas with I p=0.8 MA at large minor radius (normalized p ~ 0.7) in all channels (n e, T e, T i, V Φ, especially strong in the T e channel). Fluctuation measurements show a significant reduction in the fluctuation levels, including AE modes and broadband turbulence, at the location where an ITB forms. Linear gyrokinetic simulations also support the decrease of the growth rate of the most unstable mode during strong ITB formation. The simulation implies that strong suppression of turbulence and a positive feedback loop may be active in this process and is responsible for the spontaneous formation of large-radius ITB. Finally, in an unstable ITB phase, an ELM crash is observed to have a positive effect on transient formation of large-radius ITB. The formation of this kind of ITB is found to have a shielding (protecting) effect on the core plasma while isolating the perturbation due to ELM crash.« less
Ding, S.; Xu, G. S.; Wang, Q.; ...
2016-09-30
A recent experiment on DIII-D, which was conducted by the joint research team from DIII-D and EAST, has extended the previous high β p, high q min regime, which has been tested in the 2013 DIII-D/EAST joint experiment, to inductive operation at higher plasma current (I p=0.8 MA) and significantly higher normalized fusion performance (G = H 89β N/=qmore » $$2\\atop{95}$$ = 0.16). The experiment aims at exploring high performance scenario with q min > 2 and reduced torque for long pulse operation, which can be potentially extrapolated to EAST. The effort was largely motivated by the interest in developing a feasible scenario for long-pulse high performance operation with low torque on EAST. Very high confinement, H 89 = 3.5 or H 98,y2 = 2.1 with β N ~ 3.0, has been achieved transiently in this experiment together with q min > 2 and reduced NBI torque (3~5 N-m). The excellent confinement is associated with the spontaneous formation of an internal transport barrier (ITB) in plasmas with I p=0.8 MA at large minor radius (normalized p ~ 0.7) in all channels (n e, T e, T i, V Φ, especially strong in the T e channel). Fluctuation measurements show a significant reduction in the fluctuation levels, including AE modes and broadband turbulence, at the location where an ITB forms. Linear gyrokinetic simulations also support the decrease of the growth rate of the most unstable mode during strong ITB formation. The simulation implies that strong suppression of turbulence and a positive feedback loop may be active in this process and is responsible for the spontaneous formation of large-radius ITB. Finally, in an unstable ITB phase, an ELM crash is observed to have a positive effect on transient formation of large-radius ITB. The formation of this kind of ITB is found to have a shielding (protecting) effect on the core plasma while isolating the perturbation due to ELM crash.« less
Morgan, L M; Goulder, T J; Tsiolakis, D; Marks, V; Alberti, K G
1979-08-01
Five healthy volunteers and 6 diabetics were given a mixed test meal on two occasions--once with and once without 10 g guar flour. Addition of guar caused a 47% decrease in maximum post-prandial GIP levels, a 48% decrease in blood glucose and a 48% decrease in plasma insulin in normal subjects. In diabetics, addition of guar caused a 30% reduction in maximum post-prandial GIP and 58% decrease in blood glucose. Four normal and 6 diabetic subjects were given a predominantly carbohydrate meal, again with and without 10 g guar. Addition of guar caused a 78% decrease in blood glucose and a 59% decrease in plasma insulin in normal subjects. In diabetics addition of guar caused a 71% decrease in maximum post-prandial plasma GIP and a 68% decrease in blood glucose. Lowering of post-prandial blood glucose, plasma insulin and GIP levels by guar was statistically significant in every case. Addition of guar to the predominantly carbohydrate meal caused a decrease in total plasma GLI in both normal and diabetic subjects but reached statistical significance only in the normal subjects. There was a highly significant correlation (r = 0.83; p less than 0.0005) between peak post-prandial insulin levels in normal subjects and the corresponding plasma GIP concentration. The reduction of GIP or GLI secretion may, therefore, be partly responsible for the smaller rise in plasma insulin observed in normal volunteers when guar is added to meals.
Ebrahimi, Forough; Ibrahim, Baharudin; Teh, Chin-Hoe; Murugaiyah, Vikneswaran; Chan, Kit-Lam
2017-06-01
Male infertility is one of the leading causes of infertility which affects many couples worldwide. Semen analysis is a routine examination of male fertility status which is usually performed on semen samples obtained through masturbation that may be inconvenient to patients. Eurycoma longifolia (Tongkat Ali, TA), native to Malaysia, has been traditionally used as a remedy to boost male fertility. In our recent studies in rats, upon the administration of high-quassinoid content extracts of TA including TA water (TAW), quassinoid-rich TA (TAQR) extracts, and a low-quassinoid content extract including quassinoid-poor TA (TAQP) extract, sperm count (SC) increased in TAW- and TAQR-treated rats when compared to the TAQP-treated and control groups. Consequently, the rats were divided into normal- (control and TAQP-treated) and high- (TAW- and TAQR-treated) SC groups [Ebrahimi et al. 2016]. Post-treatment rat plasma was collected. An optimized plasma sample preparation method was developed with respect to the internal standards sodium 3- (trimethylsilyl) propionate- 2,2,3,3- d4 (TSP) and deuterated 4-dimethyl-4-silapentane-1-ammonium trifluoroacetate (DSA). Carr-Purcell-Meibum-Gill (CPMG) experiments combined with orthogonal partial least squares discriminant analysis (OPLS-DA) was employed to evaluate plasma metabolomic changes in normal- and high-SC rats. The potential biomarkers associated with SC increase were investigated to assess fertility by capturing the metabolomic profile of plasma. DSA was selected as the optimized internal standard for plasma analysis due to its significantly smaller half-height line width (W h/2 ) compared to that of TSP. The validated OPLS-DA model clearly discriminated the CPMG profiles in regard to the SC level. Plasma profiles of the high-SC group contained higher levels of alanine, lactate, and histidine, while ethanol concentration was significantly higher in the normal-SC group. This approach might be a new alternative applicable to the fertility assessment in humans through the quantitative metabolomic analysis of plasma without requiring semen. TA: Tongkat Ali; LOD: limit of detection; LOQ: limit of quantification; HPLC-UV: high performance liquid chromatography-ultrviolet; PDA: photodiode array; NMR: nuclear magnetic resonance; FID: free induction decay; LC-MS: liquid chromatography-mass spectrometry; GC-MS: gas chromatography-mass spectrometry; HSQC: heteronuclear single quantum coherence; CPMG: Carr-Purcell-Meibum-Gill; VLDL: very low density lipoprotein; HDL: high density lipoprotein; EDTA: ethylenediaminetetraacetic acid; ANOVA: analysis of variance; AMIX: analysis of mixtures; SIMCA: soft independent modeling of class analogy; PCA: principal components analysis; OPLS-DA: orthogonal partial least-squares discriminant analysis; VIP: variable importance plot; AUROC: area under the receiver operating characteristic; TSP: sodium 3-(trimethylsilyl) propionate- 2,2,3,3- d4; DSA: deuterated 4-dimethyl-4-silapentane-1-ammonium trifluoroacetate; ESI: electrospray ionization; TCA: trichloroacetic acid; ACN: acetonitrile; dd H 2 O: distilled deionized water; FSH: follicle-stimulating hormone; LH: luteinizing hormone; OECD: Organisation for Economic Co-operation and Development.
Central Safety Factor and Normalized Beta Control Under Near-Zero Input Torque Constraints in DIII-D
NASA Astrophysics Data System (ADS)
Pajares, Andres; Wehner, William; Schuster, Eugenio; Burrell, Keith; Ferron, John; Walker, Michael; Humphreys, David; Lehigh University Team; Atomics Team, General
2017-10-01
DIII-D experiments have assessed the capability of combined central safety factor (q0) and normalized beta (βN) control under near-zero net torque to facilitate access to QH-mode with reverse Ip and normal Bt. Regulation of q0 and βN can prevent magneto-hydrodynamic instabilities that deteriorate plasma performance in discharges with a monotonically increasing safety-factor profile. Zero-input-torque scenarios are of special interest because future burning plasma tokamaks such as ITER will most likely operate with very low input torque, which makes these scenarios more susceptible to locked modes. To support studies of such scenarios, a controller for simultaneous regulation of q0 and βN has been developed using near-zero net input torque actuators including balanced neutral beam injection (NBI) and electron-cyclotron heating & current drive (ECH/ECCD). Experimental results show that in spite of the presence of locked modes the use of feedback control resulted in good tracking of the commanded q0 and βN when both ECCD/ECH and NBI were available. Supported by the US DOE under DE-SC0010661 and DE-FC02-04ER54698.
Improved confinement in highly powered high performance scenarios on DIII-D
DOE Office of Scientific and Technical Information (OSTI.GOV)
Petrie, Thomas W.; Osborne, Thomas; Fenstermacher, Max E.
DIII-D has recently demonstrated improved energy confinement by injecting neutral deuterium gas into high performance near-double null divertor (DND) plasmas during high power operation. Representative parameters for these plasmas are: q 95 = 6, P IN up to 15 MW, H 98 = 1.4–1.8, and β N = 2.5–4.0. The ion B xmore » $$\\triangledown$$B direction is away from the primary X-point. While plasma conditions at lower to moderate power input (e.g., 11 MW) are shown to be favorable to successful puff-and-pump radiating divertor applications, particularly when using argon seeds, plasma behavior at higher powers (e.g., ≥14 MW) may make successful puff-and-pump operation more problematic. In contrast to lower powered high performance plasmas, both $$\\tau$$ E and β N in the high power cases (≥14 MW) increased and ELM frequency decreased, as density was raised by deuterium gas injection. Improved performance in the higher power plasmas was tied to higher pedestal pressure, which according to peeling-ballooning mode stability analysis using the ELITE code could increase with density along the kink/peeling stability threshold, while the pedestal pressure gradient in the lower power discharges were limited by the ballooning threshold. This resulted in improved fueling efficiency and ≈10% higher $$\\tau$$ E and β N than is normally observed in comparable high performance plasmas on DIII-D. Applying the puff-and-pump radiating divertor approach at moderate versus high power input is shown to result in a much different evolution in core and pedestal plasma behavior. In conclusion, we find that injecting deuterium gas into these highly powered DND plasmas may open up a new avenue for achieving elevated plasma performance, including better fueling, but the resulting higher density may also complicate application of a radiating divertor approach to heat flux reduction in present-day tokamaks, if scenarios involving second-harmonic electron cyclotron heating are used.« less
Improved confinement in highly powered high performance scenarios on DIII-D
Petrie, Thomas W.; Osborne, Thomas; Fenstermacher, Max E.; ...
2017-06-09
DIII-D has recently demonstrated improved energy confinement by injecting neutral deuterium gas into high performance near-double null divertor (DND) plasmas during high power operation. Representative parameters for these plasmas are: q 95 = 6, P IN up to 15 MW, H 98 = 1.4–1.8, and β N = 2.5–4.0. The ion B xmore » $$\\triangledown$$B direction is away from the primary X-point. While plasma conditions at lower to moderate power input (e.g., 11 MW) are shown to be favorable to successful puff-and-pump radiating divertor applications, particularly when using argon seeds, plasma behavior at higher powers (e.g., ≥14 MW) may make successful puff-and-pump operation more problematic. In contrast to lower powered high performance plasmas, both $$\\tau$$ E and β N in the high power cases (≥14 MW) increased and ELM frequency decreased, as density was raised by deuterium gas injection. Improved performance in the higher power plasmas was tied to higher pedestal pressure, which according to peeling-ballooning mode stability analysis using the ELITE code could increase with density along the kink/peeling stability threshold, while the pedestal pressure gradient in the lower power discharges were limited by the ballooning threshold. This resulted in improved fueling efficiency and ≈10% higher $$\\tau$$ E and β N than is normally observed in comparable high performance plasmas on DIII-D. Applying the puff-and-pump radiating divertor approach at moderate versus high power input is shown to result in a much different evolution in core and pedestal plasma behavior. In conclusion, we find that injecting deuterium gas into these highly powered DND plasmas may open up a new avenue for achieving elevated plasma performance, including better fueling, but the resulting higher density may also complicate application of a radiating divertor approach to heat flux reduction in present-day tokamaks, if scenarios involving second-harmonic electron cyclotron heating are used.« less
Programmable Pulse Generator for Aditya Gas Puffing System
NASA Astrophysics Data System (ADS)
Patel, Narendra; Chavda, Chhaya; Bhatt, S. B.; Chattopadhyay, Prabal; Saxena, Y. C.
2012-11-01
In the Aditya Tokamak, one of primary requirement for plasma generation is to feed the required quantity of the fuel gas prior to plasma shot. Gas feed system mainly consists of piezoelectric gas leak valve and gas reservoir. The Hydrogen gas is prior to 300ms loop voltage for the duration of 4 msec to 7 msec. Gas is puffed during the shot for required plasma parameters and to increase plasma density using the same system. The valve is controlled by either continuous voltage or pulses of different width, amplitude and delay with respect to loop voltage. These voltage pulses are normally applied through standard pulse generator. The standard pulse generator is replaced by micro controller based in housed developed programmable pulse generator system consists of in built power supply, BNC input for external trigger, BNC output and serial interface. This programmable pulse generator is successfully tested and is in operation for gas puffing during ADITYA Tokamak experiments. The paper discusses the design and development aspect of the system.
Zn concentration in plasma and gastric fluid in patients with upper gastrointestinal disease
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kadakia, S.C.; Wong, R.H.K.; Maydonovitch, C.
1986-03-05
Very few data are available about Zn in gastrointestinal fluids in humans. To obtain data in one such fluid Zn was measured in plasma and gastric fluid, obtained by direct visual aspiration through an endoscope placed into the gastric fundus, in 36 subjects with normal gastrointestinal mucosa (N) and in 36 patients with the following upper gastrointestinal pathology confirmed by endoscopy: 13 with esophagitis (E), 9 with gastritis (G) and 14 with duodenal ulcer disease (DU). Plasma and gastric fluid Zn were estimated by flame atomic absorption spectrophotometry. Mean plasma Zn was significantly lower than normal in patients with Emore » (N, 87 +/- 2 ..mu..g/dl, M +/- SEM; E, 75 +/- 4, p < 0.01) but plasma values were similar to normal in the other patient groups (G, 89 +/- 4; DU, 87 +/- 2). Mean gastric fluid zinc in G was significantly higher than in normal subjects (G, 664 +/- 159 ..mu..g/L; N, 360 +/- 43, p < 0.02) but not significantly different from normal in patients with DU or E (DU, 402 +/- 76; E, 307 +/- 55). Mean gastric fluid Zn in women with DU was approximately 45% higher than in men with DU, although it was 17% lower in normal women than in normal men. Compared to other normal tissues gastric fluid Zn is about 1/3 that in serum and about 3 times that in saliva. These results indicate that Zn in plasma and gastric fluid is altered in some upper gastrointestinal diseases.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhai, Y.; Loesser, G.; Smith, M.
ITER diagnostic first walls (DFWs) and diagnostic shield modules (DSMs) inside the port plugs (PPs) are designed to protect diagnostic instrument and components from a harsh plasma environment and provide structural support while allowing for diagnostic access to the plasma. The design of DFWs and DSMs are driven by 1) plasma radiation and nuclear heating during normal operation 2) electromagnetic loads during plasma events and associate component structural responses. A multi-physics engineering analysis protocol for the design has been established at Princeton Plasma Physics Laboratory and it was used for the design of ITER DFWs and DSMs. The analyses weremore » performed to address challenging design issues based on resultant stresses and deflections of the DFW-DSM-PP assembly for the main load cases. ITER Structural Design Criteria for In-Vessel Components (SDC-IC) required for design by analysis and three major issues driving the mechanical design of ITER DFWs are discussed. The general guidelines for the DSM design have been established as a result of design parametric studies.« less
Investigation of Plasma Surface Interactions with the PISCES ELM Laser System
NASA Astrophysics Data System (ADS)
Umstadter, K. R.; Baldwin, M.; Hanna, J.; Doerner, R.; Lynch, T.; Palmer, T.; Tynan, G. R.
2007-11-01
When an ELM occurs in tokamaks, up to 30% of the pedestal energy can be deposited on the wall of the tokamak causing heating & material loss due to sublimation, evaporation and melt splashing of plasma facing components (PFCs) and expansion of the ejected material into the plasma. We have explored heat pulses using an electrical power circuit to draw electrons from the plasma to heat samples ohmically. This system is limited in power to ˜250kJ/m^2 at the minimum pulse width of 10ms and depletes the plasma column, complicating spectroscopy. We have completed calculations that indicate that a pulsed laser system can be used to simulate the heat pulse of ELMs. We are integrating laser systems into the existing PFC research program in PISCES, a laboratory facility capable of reproducing plasma-materials interactions expected during normal operation of large tokamaks. Two Nd:YAG lasers capable of delivering up to 50J of energy over various pulsewidths are used for the experiments. Laser heat pulse only, H+/D+ plasma only, and laser+plasma experiments were conducted and initial results indicate that metals behave very differently while exposed to plasma and simultaneous heat pulses. We will also discuss initial results for carbon PFCs and material transport into the plasma. Supported by US DoE grant DE-FG02-07ER-54912.
NASA Astrophysics Data System (ADS)
Stratton, B. C.; Budny, R. V.; Darrow, D. S.; Fisher, R. K.; Fredrickson, E. D.; Fu, G. Y.; Medley, S. S.; Nazikian, R.; Petrov, M. P.; Redi, M. H.; Ruskov, E.; Taylor, G.; White, R. B.; Zweben, S. J.; TFTR Group
1999-09-01
The article reviews the physics of fusion alpha particles and energetic neutral beam ions studied in the final phase of TFTR operation, with an emphasis on observations in reversed magnetic shear (RS) and enhanced reversed shear (ERS) DT plasmas. Energy resolved measurements of the radial profiles of confined, trapped alphas in RS plasmas exhibit reduced core alpha density with increasing alpha energy, in contrast to plasmas with normal monotonic shear. The measured profiles are consistent with predictions of increased alpha loss due to stochastic ripple diffusion and increased first orbit loss in RS plasmas. In experiments in which a short tritium beam pulse is injected into a deuterium RS plasma, the measured DT neutron emission is lower than standard predictions assuming first orbit loss and stochastic ripple diffusion of the beam ions. A microwave reflectometer measured the spatial localization of low toroidal mode number (n), alpha driven toroidal Alfvén eigenmodes (TAEs) in DT RS discharges. Although the observed ballooning character of the n = 4 mode is consistent with predictions of a kinetic MHD stability code, the observed antiballooning nature of the n = 2 mode is not. Furthermore, the modelling does not show the observed strong dependence of mode frequency on n. These alpha driven TAEs do not cause measurable alpha loss in TFTR. Other Alfvén frequency modes with n = 2-4 seen in both DT and DD ERS and RS discharges are localized to the weak magnetic shear region near qmin. In 10-20% of DT discharges, normal low n MHD activity causes alpha loss at levels above the first orbit loss rate.
Radioimmunoassay of human Hageman factor (factor XII). [/sup 125/I tracer technique
DOE Office of Scientific and Technical Information (OSTI.GOV)
Saito, H.; Ratnoff, O.D.; Pensky, J.
A specific, sensitive, and reproducible radioimmunoassay for human Hageman factor (HF, factor XII) has been developed with purified human HF and monospecific rabbit antibody. Precise measurements of HF antigen were possible for concentrations as low as 0.1 percent of that in normal pooled plasma. A good correlation (correlation coefficient = 0.82) existed between the titers of HF measured by clot-promoting assays and radioimmunoassays among 42 normal adults. Confirming earlier studies, HF antigen was absent in Hageman trait plasma, but other congenital deficient plasmas, including those of individuals with Fletcher trait and Fitzgerald trait, contained normal amounts of HF antigen. HFmore » antigen was reduced in the plasmas of patients with disseminated intravascular coagulation or advanced liver cirrhosis, but it was normal in those of patients with chronic renal failure or patients under treatment with warfarin. HF antigen was detected by this assay in plasmas of primates, but not detectable in plasmas of 11 nonprimate mammalian and one avian species.« less
BLOOD PLASMA PROTEIN GIVEN BY VEIN UTILIZED IN BODY METABOLISM
Holman, Russell L.; Mahoney, Earle B.; Whipple, George H.
1934-01-01
Large amounts of normal blood plasma can be given intravenously to normal dogs over several weeks without causing any significant escape by way of the urine. There appears to be no renal threshold for plasma protein even with high plasma protein concentration (9.7 per cent). Dogs receiving sugar by mouth and plasma by vein can be kept practically in nitrogen equilibrium and it would seem that the injected protein must be utilized by the body. If this can happen in this emergency we may suspect that normally there is a certain amount of "give and take" between body protein and plasma protein. Plasma protein fed by mouth under identical conditions shows the same general reaction as noted with plasma by vein but the urinary nitrogen is a little higher and suggests that the injected protein is utilized a little more completely to form new protein. The difference may be explained as due to deaminization in the case of protein by mouth. During fasting periods the blood plasma proteins are used up and the total circulating protein may even decrease to one-half the normal level. The plasma protein concentration changes but little and the significant change is a shrinkage of plasma volume. All these facts point to a dynamic equilibrium between tissue protein and plasma protein depending upon the physiological needs of the moment. In the absence of food protein the body can use material coming from one body protein to fabricate badly needed protein material of different character. PMID:19870245
NASA Astrophysics Data System (ADS)
Polevoi, A. R.; Loarte, A.; Dux, R.; Eich, T.; Fable, E.; Coster, D.; Maruyama, S.; Medvedev, S. Yu.; Köchl, F.; Zhogolev, V. E.
2018-05-01
ELM mitigation to avoid melting of the tungsten (W) divertor is one of the main factors affecting plasma fuelling and detachment control at full current for high Q operation in ITER. Here we derive the ITER operational space, where ELM mitigation to avoid melting of the W divertor monoblocks top surface is not required and appropriate control of W sources and radiation in the main plasma can be ensured through ELM control by pellet pacing. We apply the experimental scaling that relates the maximum ELM energy density deposited at the divertor with the pedestal parameters and this eliminates the uncertainty related with the ELM wetted area for energy deposition at the divertor and enables the definition of the ITER operating space through global plasma parameters. Our evaluation is thus based on this empirical scaling for ELM power loads together with the scaling for the pedestal pressure limit based on predictions from stability codes. In particular, our analysis has revealed that for the pedestal pressure predicted by the EPED1 + SOLPS scaling, ELM mitigation to avoid melting of the W divertor monoblocks top surface may not be required for 2.65 T H-modes with normalized pedestal densities (to the Greenwald limit) larger than 0.5 to a level of current of 6.5–7.5 MA, which depends on assumptions on the divertor power flux during ELMs and between ELMs that expand the range of experimental uncertainties. The pellet and gas fuelling requirements compatible with control of plasma detachment, core plasma tungsten accumulation and H-mode operation (including post-ELM W transient radiation) have been assessed by 1.5D transport simulations for a range of assumptions regarding W re-deposition at the divertor including the most conservative assumption of zero prompt re-deposition. With such conservative assumptions, the post-ELM W transient radiation imposes a very stringent limit on ELM energy losses and the associated minimum required ELM frequency. Depending on W transport assumptions during the ELM, a maximum ELM frequency is also identified above which core tungsten accumulation takes place.
Plasma Processing with a One Atmosphere Uniform Glow Discharge Plasma (OAUGDP)
NASA Astrophysics Data System (ADS)
Reece Roth, J.
2000-10-01
The vast majority of all industrial plasma processing is conducted with glow discharges at pressures below 10 torr. This has limited applications to high value workpieces as a result of the large capital cost of vacuum systems and the production constraints of batch processing. It has long been recognized that glow discharges would play a much larger industrial role if they could be operated at one atmosphere. The One Atmosphere Uniform Glow Discharge Plasma (OAUGDP) has been developed at the University of Tennessee Plasma Sciences Laboratory. The OAUGDP is non-thermal RF plasma with the time-resolved characteristics of a classical low pressure DC normal glow discharge. An interdisciplinary team was formed to conduct exploratory investigations of the physics and applications of the OAUGDP. This team includes collaborators from the UTK Textiles and Nonwovens Development Center (TANDEC) and the Departments of Electrical and Computer Engineering, Microbiology, Food Science and Technology, and Mechanical and Aerospace Engineering and Engineering Science. Exploratory tests were conducted on a variety of potential plasma processing and other applications. These include the use of OAUGDP to sterilize medical and dental equipment and air filters; diesel soot removal; plasma aerodynamic effects; electrohydrodynamic (EDH) flow control of the neutral working gas; increasing the surface energy of materials; increasing the wettability and wickability of fabrics; and plasma deposition and directional etching. A general overview of these topics will be presented.
Blood-Brain Glucose Transfer: Repression in Chronic Hyperglycemia
NASA Astrophysics Data System (ADS)
Gjedde, Albert; Crone, Christian
1981-10-01
Diabetic patients with increased plasma glucose concentrations may develop cerebral symptoms of hypoglycemia when their plasma glucose is rapidly lowered to normal concentrations. The symptoms may indicate insufficient transport of glucose from blood to brain. In rats with chronic hyperglycemia the maximum glucose transport capacity of the blood-brain barrier decreased from 400 to 290 micromoles per 100 grams per minute. When plasma glucose was lowered to normal values, the glucose transport rate into brain was 20 percent below normal. This suggests that repressive changes of the glucose transport mechanism occur in brain endothelial cells in response to increased plasma glucose.
Ikegami, Hiroko; Kawawa, Rie; Ichi, Ikuyo; Ishikawa, Tomoko; Koike, Taisuke; Aoki, Yoshinori; Fujiwara, Yoko
2017-10-01
Background: Animal studies on the effects of vitamin E on bone health have yielded conflicting and inconclusive results, and to our knowledge, no studies have addressed the effect of vitamin E on bone in animals consuming a high-fat diet (HFD). Objective: This study aimed to evaluate the effect of excessive vitamin E on bone metabolism in normal male mice and ovariectomized female mice fed a normal diet (ND) or HFD. Methods: In the first 2 experiments, 7-wk-old male mice were fed an ND (16% energy from fat) containing 75 (control), 0 (vitamin E-free), or 1000 (high vitamin E) mg vitamin E/kg (experiment 1) or an HFD (46% energy from fat) containing 0, 200, 500, or 1000 mg vitamin E/kg (experiment 2) for 18 wk. In the third experiment, 7-wk-old sham-operated or ovariectomized female mice were fed the ND (75 mg vitamin E/kg) or HFD containing 0 or 1000 mg vitamin E/kg for 8 wk. At the end of the feeding period, blood and femurs were collected to measure bone turnover markers and analyze histology and microcomputed tomography. Results: In experiments 1 and 2, vitamin E intake had no effect on plasma alkaline phosphatase (ALP), tartrate-resistant acid phosphatase (TRAP) activity, or bone formation, resorption, or volume in femurs in mice fed the ND or HFDs. In experiment 3, bone volume was significantly reduced (85%) in ovariectomized mice compared with that in sham-operated mice ( P < 0.05), but it did not differ among mice fed the 3 diets. Plasma ALP and TRAP activities and bone formation and resorption in femur were similar among ovariectomized mice fed the HFD containing 0 or 1000 mg vitamin E/kg. Conclusions: The results suggest that excess vitamin E intake does not cause bone loss in normal male mice or in ovariectomized or sham-operated female mice, regardless of dietary fat content. © 2017 American Society for Nutrition.
Mohammadzadeh, G S; Nasseri Moghadam, S; Rasaee, M J; Zaree, A B; Mahmoodzadeh, H; Allameh, A
2003-06-01
To develop an indirect enzyme-linked immunosorbent assay (ELISA) for measuring class-pi glutathione S-transferase (GST) in plasma, and tissue biopsies obtained from upper gastrointestinal cancer (UGI Ca) patients. GST activity and GST-pi concentration were detected in normal human squamous esophageal epithelium, normal gastric cardia and their corresponding malignant tumor biopsies. Plasma GST was significantly higher (p < 0.05) in UGI Ca patients as compared to those obtained from normal individuals. Plasma GST-pi concentration in normal subjects was 6.6 +/- 1.9 ng/mg protein, whereas it was higher in UGI Ca patients (esophageal, 10.0 +/- 1.8; gastric, 10.7 +/- 1.7 ng/mL, p
Croughs, R J; Thijssen, J H; Mol, J A
1991-03-01
We have measured alpha-MSH in plasma of normal subjects and subjects with various diseases of the pituitary-adrenocortical system using a radioimmunoassay with a sensitivity of 1.2 pmol/l. No alpha-MSH could be detected in plasma of normal subjects (n = 6), in plasma of patients with Addison's disease (n = 3), Nelson's syndrome (n = 2), bromocriptine responsive (n = 2) and unresponsive (n = 5) Cushing's disease and in plasma of psychiatric patients on chronic treatment with the dopamine antagonist haloperidol (n = 5). Plasma alpha-MSH remained undetectable in 2 patients with Cushing's disease after iv injection of 60 micrograms/kg haloperidol. In contrast, alpha-MSH was detectable in plasma of normal dogs (n = 2) and dogs with pituitary dependent hyperadrenocorticism (n = 2), whereas the iv injection of halo peridol was associated with a rise of plasma alpha-MSH. Thus we are unable to detect circulating alpha-MSH in man despite the use of a sensitive radioimmunoassay.
Low voltage operation of plasma focus.
Shukla, Rohit; Sharma, S K; Banerjee, P; Das, R; Deb, P; Prabahar, T; Das, B K; Adhikary, B; Shyam, A
2010-08-01
Plasma foci of compact sizes and operating with low energies (from tens of joules to few hundred joules) have found application in recent years and have attracted plasma-physics scientists and engineers for research in this direction. We are presenting a low energy and miniature plasma focus which operates from a capacitor bank of 8.4 muF capacity, charged at 4.2-4.3 kV and delivering approximately 52 kA peak current at approximately 60 nH calculated circuit inductance. The total circuit inductance includes the plasma focus inductance. The reported plasma focus operates at the lowest voltage among all reported plasma foci so far. Moreover the cost of capacitor bank used for plasma focus is nearly 20 U.S. dollars making it very cheap. At low voltage operation of plasma focus, the initial breakdown mechanism becomes important for operation of plasma focus. The quartz glass tube is used as insulator and breakdown initiation is done on its surface. The total energy of the plasma focus is approximately 75 J. The plasma focus system is made compact and the switching of capacitor bank energy is done by manual operating switch. The focus is operated with hydrogen and deuterium filled at 1-2 mbar.
Sarcoidosis mimicking toxoplasmosis with severe hypercalcaemia and normal 1,25-dihydroxy vitamin D.
Levy, Y; Hayek, T; Finkelstein, R
1996-09-01
We report a case of a female patient with sarcoidosis who presented with a generalized lymphadenopathy and a strong IgG serological test of toxoplasmosis. Progressive lymphadenopathy with a rising plasma calcium (up to 15 mg dL-1) with a normal plasma 1,25-dihydroxy vitamin D concentration occurred later. Corticosteroid therapy resulted in prompt clinical and biochemical responses with normalization of plasma calcium and a significant reduction in 1,25-dihydroxy vitamin D concentration. This is an exceptional presentation of sarcoidosis with severe hypercalcaemia and normal vitamin D metabolites.
Yang, Li; Lv, Pu; Ai, Wanpeng; Li, Linnan; Shen, Sensen; Nie, Honggang; Shan, Yabing; Bai, Yu; Huang, Yining; Liu, Huwei
2017-05-01
Stroke is a major cause of mortality and long-term disability worldwide. The study of biomarkers and pathogenesis is vital for early diagnosis and treatment of stroke. In the present study, a continuous-flow normal-phase/reversed-phase two-dimensional liquid chromatography-quadrupole time-of-flight mass spectrometry (NP/RP 2D LC-QToF/MS) method was employed to measure lipid species in human plasma, including healthy controls and lacunar infarction (LI) patients. As a result, 13 lipid species were demonstrated with significant difference between the two groups, and a "plasma biomarker model" including glucosylceramide (38:2), phosphatidylethanolamine (35:2), free fatty acid (16:1), and triacylglycerol (56:5) was finally established. This model was evaluated as an effective tool in that area under the receiver operating characteristic curve reached 1.000 in the discovery set and 0.947 in the validation set for diagnosing LI patients from healthy controls. Besides, the sensitivity and specificity of disease diagnosis in validation set were 93.3% and 96.6% at the best cutoff value, respectively. This study demonstrates the promising potential of NP/RP 2D LC-QToF/MS-based lipidomics approach in finding bio-markers for disease diagnosis and providing special insights into the metabolism of stroke induced by small vessel disease. Graphical abstract Flow-chart of the plasma biomarker model establishment through biomarker screening and validation.
Tao, H; Rajendran, R B; Quetel, C R; Nakazato, T; Tominaga, M; Miyazaki, A
1999-10-01
A sensitive method for the determination of ultratrace organotin species in seawater is described. The merits and demerits of derivatization methods using Grignard reagent or sodium tetraethylborate (NaBEt4) were evaluated in terms of derivatization efficiency, applicability to the programmed temperature vaporization (PTV) method, and procedural blanks. The sensitivity of the gas chromatography/inductively coupled plasma mass spectrometry (GC/ICPMS) was improved by more than 100-fold by operating the shield torch at normal plasma conditions, compared with that obtained without using it. The absolute detection limit as tin reached subfemtogram (fg) levels. Furthermore, the detection limit in terms of relative concentration was improved 100-fold by using the PTV method, which enabled the injection of a large sample volume of as much as 100 microL without loss of analyte. When the organotin species in seawater were extracted into hexane with a preconcentration factor of 1000 after ethylation with NaBEt4 and a 100 microL aliquot of the extract was injected into the GC, the instrumental detection limit in relative concentration reached 0.01 pg/L in original seawater. Sources of contamination of organotin species during the sample preparation were examined, and a purification method of NaBEt4 was developed. Finally, the method was successfully applied to open ocean seawater samples containing organotin species at the level of 1-100 pg/L.
Behavior of an indigenously fabricated transferred arc plasma furnace for smelting studies
NASA Astrophysics Data System (ADS)
A, K. MANDAL; R, K. DISHWAR; O, P. SINHA
2018-03-01
The utilization of industrial solid waste for metal recovery requires high-temperature tools due to the presence of silica and alumina, which is reducible at high temperature. In a plasma arc furnace, transferred arc plasma furnace (TAP) can meet all requirements, but the disadvantage of this technology is the high cost. For performing experiments in the laboratory, the TAP was fabricated indigenously in a laboratory based on the different inputs provided in the literature for the furnace design and fabrication. The observed parameters such as arc length, energy consumption, graphite electrode consumption, noise level as well as lining erosion were characterized for this fabricated furnace. The nitrogen plasma increased by around 200 K (200 °C) melt temperature and noise levels decreased by ∼10 dB compared to a normal arc. Hydrogen plasma offered 100 K (100 °C) higher melt temperature with ∼5 dB higher sound level than nitrogen plasma. Nitrogen plasma arc melting showed lower electrode and energy consumption than normal arc melting, whereas hydrogen plasma showed lower energy consumption and higher electrode consumption in comparison to nitrogen plasma. The higher plasma arc temperature resulted in a shorter meltdown time than normal arc with smoother arcing. Hydrogen plasma permitted more heats, reduced meltdown time, and lower energy consumption, but with increased graphite consumption and crucible wear. The present study showed that the fabricated arc plasma is better than the normal arc furnace with respect to temperature generation, energy consumption, and environmental friendliness. Therefore, it could be used effectively for smelting-reduction studies.
BLOOD PLASMA PROTEIN REGENERATION AS INFLUENCED BY FASTING, INFECTION, AND DIET FACTORS
Madden, S. C.; George, W. E.; Waraich, G. S.; Whipple, H.
1938-01-01
When blood plasma proteins are depleted by bleeding, with return of the washed red cells (plasmapheresis) it is possible to bring dogs to a steady state of hypoproteinemia and a uniform plasma protein production on a basal low protein diet. These dogs are clinically normal with normal appetite, no anemia and normal nitrogen metabolism. These dogs become test subjects by which various factors relating to plasma protein production may be tested. The normal dog (10 to 13 kg.) has a substantial reserve store of plasma protein building material (10 to 60+ gm.) which requires 2 to 6 weeks plasmapheresis for its complete removal. After this period the dog will produce uniform amounts of plasma protein each week on a fixed basal diet. Dogs previously depleted by plasmapheresis and then permitted to return to normal during a long rest period of many weeks, may show much higher reserve stores of protein building material in subsequent periods of plasma depletion (see Table 1). Under uniform conditions of low protein diet intake when plasmapheresis is discontinued for 2 weeks the plasma protein building material is stored quantitatively in the body and can subsequently be recovered (Table 4) in the next 2 to 3 weeks of plasmapheresis. Given complete depletion of plasma protein building reserve stores the dog can produce very little (2± gm. per week) plasma protein on a protein-free diet. This may be related to the wear and tear of body protein and conservation of these split products. Abscesses produced in a depleted dog during a fast may cause some excess production of plasma protein which is probably related to products of tissue destruction conserved for protein anabolism. Gelatin alone added to the basal diet causes very little plasma protein production but when supplemented by tryptophane gives a large protein output, while tryptophane alone is inert. PMID:19870748
Magnetic shielding of large high-power-satellite solar arrays using internal currents
NASA Technical Reports Server (NTRS)
Parker, L. W.; Oran, W. A.
1979-01-01
Present concepts for solar power satellites involve dimensions up to tens of kilometers and operating internal currents up to hundreds of kiloamperes. A question addressed is whether the local magnetic fields generated by these strong currents during normal operation can shield the array against impacts by plasma ions and electrons (and from thruster plasmas) which can cause possible losses such as power leakage and surface erosion. One of several prototype concepts was modeled by a long narrow rectangular panel 2 km wide and 20 km long. The currents flow in a parallel across the narrow dimension (sheet current) and along the edge (wire currents). The wire currents accumulate from zero to 100 kiloamp and are the dominant sources. The magnetic field is approximated analytically. The equations of motion for charged particles in this magnetic field are analyzed. The ion and electron fluxes at points on the surface are represented analytically for monoenergetic distributions and are evaluated.
Harrison, Noel; Field, John R; Quondamatteo, Fabio; Curtin, William; McHugh, Peter E; Mc Donnell, Pat
2014-09-01
A new surface architecture for cementless orthopaedic implants (OsteoAnchor), which incorporates a multitude of tiny anchor features for enhancing primary fixation, was tested in an ovine hemi-arthroplasty pilot study. Test animals were implanted with a hip stem component incorporating the OsteoAnchor surface architecture produced using additive layer manufacturing and control animals were implanted with stems containing a standard plasma sprayed titanium coating. Intra-operative surgeon feedback indicated that superior primary fixation was achieved for the OsteoAnchor stems and rapid return to normal gait and load bearing was observed post-operation. Following a 16-week recovery time, histological evaluation of the excised femurs revealed in-growth of healthy bone into the porous structure of the OsteoAnchor stems. Bone in-growth was not achieved for the plasma sprayed stems. These results indicate the potential for the OsteoAnchor surface architecture to enhance both the initial stability and long term lifetime of cementless orthopaedic implants. Copyright © 2014 Elsevier Ltd. All rights reserved.
Amoako, Akwasi Atakora; Marczylo, Timothy Hywel; Elson, Janine; Taylor, Anthony Henry; Willets, Jonathon M; Konje, Justin Chi
2014-11-01
To determine whether changes in seminal plasma concentrations of the endogenous lipid signaling molecules palmitoylethanolamide (PEA) and oleoylethanolamide (OEA) have significant effects on sperm quality. Biochemical and physiological studies of human seminal plasma and spermatozoa. Academic tertiary care medical center. Ninety men attending an infertility clinic for semen analysis. Palmitoylethanolamide and OEA extracted from seminal plasma were quantified by ultra high-performance liquid chromatography (HPLC)-tandem mass spectrometry. Patient sperm from semen with normal parameters were exposed in vitro to PEA or OEA to determine effects on sperm motility, viability, and mitochondrial activity. The relationship between seminal plasma concentrations of PEA and OEA and sperm quality and the effect of these compounds on sperm motility, viability, and mitochondria activity in vitro. Palmitoylethanolamide and OEA concentrations in seminal plasma were lower in men with asthenozoospermia and oligoasthenoteratozospermia compared with men with normal semen parameters. Palmitoylethanolamide and OEA rapidly and significantly improved sperm motility and maintained viability without affecting mitochondria activity in vitro. Maintenance of normal PEA and OEA tone in human seminal plasma may be necessary for the preservation of normal sperm function and male fertility. Exocannabinoids found in Cannabis, such as delta-9-tetrahydrocannabinol and cannabidiol, could compete with these endocannabinoids upsetting their finely balanced, normal functioning and resulting in male reproductive failure. Copyright © 2014 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.
Modeling Electrothermal Plasma with Boundary Layer Effects
NASA Astrophysics Data System (ADS)
AlMousa, Nouf Mousa A.
Electrothermal plasma sources produce high-density (1023-10 28 /m3) and high temperature (1-5 eV) plasmas that are of interest for a variety of applications such as hypervelocity launch devices, fusion reactor pellet injectors, and pulsed thrusters for small satellites. Also, the high heat flux (up to 100 GW/m2) and high pressure (100s MPa) of electrothermal (ET) plasmas allow for the use of such facilities as a source of high heat flux to simulate off-normal events in Tokamak fusion reactors. Off-normal events like disruptions, thermal and current quenches, are the perfect recipes for damage of plasma facing components (PFC). Successful operation of a fusion reactor requires comprehensive understanding of material erosion behavior. The extremely high heat fluxes deposited in PFCs melt and evaporate or directly sublime the exposed surfaces, which results in a thick vapor/melt boundary layer adjacent to the solid wall structure. The accumulating boundary layers provide a self-protecting nature by attenuating the radiant energy transport to the PFCs. The ultimate goal of this study is to develop a reliable tool to adequately simulate the effect of the boundary layers on the formation and flow of the energetic ET plasma and its impact on exposed surfaces erosion under disruption like conditions. This dissertation is a series of published journals/conferences papers. The first paper verified the existence of the vapor shield that evolved at the boundary layer under the typical operational conditions of the NC State University ET plasma facilities PIPE and SIRENS. Upon the verification of the vapor shield, the second paper proposed novel model to simulate the evolution of the boundary layer and its effectiveness in providing a self-protecting nature for the exposed plasma facing surfaces. The developed models simulate the radiant heat flux attenuation through an optically thick boundary layer. The models were validated by comparing the simulation results to experimental data taken from the ET plasma facilities. Upon validation of the boundary layer models, computational experiments were conducted with the purpose of evaluation the PFCs' erosion during plasma disruption in Tokamak fusion reactors. Erosion of a set of selected low-Z and high-Z materials were analyzed and discussed. For metallic plasma facing materials under the impact of hard and long time-scale disruption events, melting and melt-layer splashing become dominate erosion mechanisms during plasma-material interaction. In order to realistically assess the erosion of the metallic fusion reactor components, the fourth paper accounts for the various mechanisms by which material evolved from PFCs due to melting and vaporization, with a developed melting and splattering/splashing model incorporated in the ET plasma code. Also, the shielding effect associated with melt-layer and vapor-layer is investigated. The quantitative results of material erosion with the boundary layer effects including a vapor layer, melt layer and splashing effects is a new model and an important step towards achieving a better understanding of plasma-material interactions under exposure to such high heat flux conditions.
Gu, Yu-Chun; Chen, De-Zhen
1997-01-01
AIM: To study the immunoreactivity of the Chinese medicine Shenrouyangzhentang to vasoactive intestinal polypeptide (VIP) and its therapeutic mechanism. METHODS: The immunoreactivity of the Chinese medicine Shenrouyangzhentang to VIP was detected in the plasma of 20 normal people and 20 patients with Piyinxu (Spleen Yin deficiency) using the radioimmunoassay (RIA) method. RESULTS: The maximum binding rate B0/T was 53.29%, the non-specific binding rate N0/T was 1.170%, and the VIP standard curve was Y = 0.81983 + 0.44319X - 0.28927X2, R2 = 0.990. The VIP content in Shenrouyangzhentang was 106.6 ng/L ± 20 ng/L), while it was 90.16 ng/L ± 15 ng/L in normal human plasma and 63.25 ng/L ± 11 ng/L in the plasma of Pixinxu patients. The difference between normal plasma and Pixinxu patient plasma was statistically significant (P < 0.05). CONCLUSION: The Chinese medicine Shenrouyangzhentang demonstrated VIP immunoreactivity similar to that of normal plasma. The (vasoactive intestinal polypeptide) VIP content in Pixinxu patient plasma was lower than that in healthy subjects (P < 0.05). PMID:27041949
NASA Astrophysics Data System (ADS)
Lazović, Saša; Puač, Nevena; Miletić, Maja; Pavlica, Dušan; Jovanović, Milena; Bugarski, Diana; Mojsilović, Slavko; Maletić, Dejan; Malović, Gordana; Milenković, Pavle; Petrović, Zoran
2010-08-01
In this paper, we study the application of a plasma needle to induce necrosis in planktonic samples containing a single breed of bacteria. Two different types of bacteria, Staphylococcus aureus (ATCC 25923) and Escherichia coli (ATCC 25922), were covered in this study. In all experiments with bacteria, the samples were liquid suspensions of several different concentrations of bacteria prepared according to the McFarland standard. The second system studied in this paper was human peripheral blood mesenchymal stem cells (hPB-MSC). In the case of hPB-MSC, two sets of experiments were performed: when cells were covered with a certain amount of liquid (indirect) and when the cell sample was in direct contact with the plasma. Most importantly, the study is made with the aim to see the effects when the living cells are in a liquid medium, which normally acts as protection against the many agents that may be released by plasmas. It was found that a good effect may be expected for a wide range of initial cell densities and operating conditions causing destruction of several orders of magnitude even under the protection of a liquid. It was established independently that a temperature increase could not affect the cells under the conditions of our experiment, so the effect could originate only from the active species produced by the plasma. In the case of those hPB-MSC that were not protected by a liquid, gas flow proved to produce a considerable effect, presumably due to poor adhesion of the cells, but in a liquid the effect was only due to the plasma. Further optimization of the operation may be attempted, opening up the possibility of localized in vivo sterilization.
NASA Astrophysics Data System (ADS)
Morgan, T. W.; Rindt, P.; van Eden, G. G.; Kvon, V.; Jaworksi, M. A.; Lopes Cardozo, N. J.
2018-01-01
For DEMO and beyond, liquid metal plasma-facing components are considered due to their resilience to erosion through flowed replacement, potential for cooling beyond conduction and inherent immunity to many of the issues of neutron loading compared to solid materials. The development curve of liquid metals is behind that of e.g. tungsten however, and tokamak-based research is currently somewhat limited in scope. Therefore, investigation into linear plasma devices can provide faster progress under controlled and well-diagnosed conditions in assessing many of the issues surrounding the use of liquid metals. The linear plasma devices Magnum-PSI and Pilot-PSI are capable of producing DEMO-relevant plasma fluxes, which well replicate expected divertor conditions, and the exploration of physics issues for tin (Sn) and lithium (Li) such as vapour shielding, erosion under high particle flux loading and overall power handling are reviewed here. A deeper understanding of erosion and deposition through this work indicates that stannane formation may play an important role in enhancing Sn erosion, while on the other hand the strong hydrogen isotope affinity reduces the evaporation rate and sputtering yields for Li. In combination with the strong redeposition rates, which have been observed under this type of high-density plasma, this implies that an increase in the operational temperature range, implying a power handling range of 20-25 MW m-2 for Sn and up to 12.5 MW m-2 for Li could be achieved. Vapour shielding may be expected to act as a self-protection mechanism in reducing the heat load to the substrate for off-normal events in the case of Sn, but may potentially be a continual mode of operation for Li.
Camazine, Maraya N; Karam, Oliver; Colvin, Ryan; Leteurtre, Stephane; Demaret, Pierre; Tucci, Marisa; Muszynski, Jennifer A; Stanworth, Simon; Spinella, Philip C
2017-05-01
To determine if the use of fresh frozen plasma/frozen plasma 24 hours compared to solvent detergent plasma is associated with international normalized ratio reduction or ICU mortality in critically ill children. This is an a priori secondary analysis of a prospective, observational study. Study groups were defined as those transfused with either fresh frozen plasma/frozen plasma 24 hours or solvent detergent plasma. Outcomes were international normalized ratio reduction and ICU mortality. Multivariable logistic regression was used to determine independent associations. One hundred one PICUs in 21 countries. All critically ill children admitted to a participating unit were included if they received at least one plasma unit during six predefined 1-week (Monday to Friday) periods. All children were exclusively transfused with either fresh frozen plasma/frozen plasma 24 hours or solvent detergent plasma. None. There were 443 patients enrolled in the study. Twenty-four patients (5%) were excluded because no plasma type was recorded; the remaining 419 patients were analyzed. Fresh frozen plasma/frozen plasma 24 hours group included 357 patients, and the solvent detergent plasma group included 62 patients. The median (interquartile range) age and weight were 1 year (0.2-6.4) and 9.4 kg (4.0-21.1), respectively. There was no difference in reason for admission, severity of illness score, pretransfusion international normalized ratio, or lactate values; however, there was a difference in primary indication for plasma transfusion (p < 0.001). There was no difference in median (interquartile range) international normalized ratio reduction, between fresh frozen plasma/frozen plasma 24 hours and solvent detergent plasma study groups, -0.2 (-0.4 to 0) and -0.2 (-0.3 to 0), respectively (p = 0.80). ICU mortality was lower in the solvent detergent plasma versus fresh frozen plasma/frozen plasma 24 hours groups, 14.5% versus 29.1%%, respectively (p = 0.02). Upon adjusted analysis, solvent detergent plasma transfusion was independently associated with reduced ICU mortality (odds ratio, 0.40; 95% CI, 0.16-0.99; p = 0.05). Solvent detergent plasma use in critically ill children may be associated with improved survival. This hypothesis-generating data support a randomized controlled trial comparing solvent detergent plasma to fresh frozen plasma/frozen plasma 24 hours.
NASA Technical Reports Server (NTRS)
Haber, E.; Re, R. N.; Kourides, I. A.; Weihl, A. C.; Maloof, F.
1978-01-01
Prolactin, thyrotropin and aldosterone were measured by radioimmunoassay and plasma renin activity by the radioimmunoassay of angiotensin I in normal women before and after the intravenous injection of 200 micrograms of thyrotropin releasing hormone. Prolactin increased at 15 minutes following thyrotropin releasing hormone. Plasma renin activity was not different from control levels during the first hour following the administration of thyrotropin releasing hormone, nor did the plasma aldosterone concentration differ significantly from the control levels during this period. However, with upright posture, an increase in aldosterone and in plasma renin activity was noted, demonstrating a normal capacity to secrete aldosterone. Similarly, no change in aldosterone was seen in 9 patients with primary hypothyroidism given thyrotropin releasing hormone, despite the fact that the increase in prolactin was greater than normal. These data demonstrate that acutely or chronically elevated serum prolactin levels do not result in increased plasma aldosterone levels in humans.
Subramanian, V S; Goyal, J; Miwa, M; Sugatami, J; Akiyama, M; Liu, M; Subbaiah, P V
1999-07-09
To determine the relative importance of platelet-activating factor-acetylhydrolase (PAF-AH) and lecithin-cholesterol acyltransferase (LCAT) in the hydrolysis of oxidized phosphatidylcholines (OXPCs) to lyso-phosphatidylcholine (lyso-PC), we studied the formation and metabolism of OXPCs in the plasma of normal and PAF-AH-deficient subjects. Whereas the loss of PC following oxidation was similar in the deficient and normal plasmas, the formation of lyso-PC was significantly lower, and the accumulation of OXPC was higher in the deficient plasma. Isolated LDL from the PAF-AH-deficient subjects was more susceptible to oxidation, and stimulated adhesion molecule synthesis in endothelial cells, more than the normal LDL. Oxidation of 16:0-[1-14C]-18:2 PC, equilibrated with plasma PC, resulted in the accumulation of labeled short- and long-chain OXPCs, in addition to the labeled aqueous products. The formation of the aqueous products decreased by 80%, and the accumulation of short-chain OXPC increased by 110% in the deficient plasma, compared to the normal plasma, showing that PAF-AH is predominantly involved in the hydrolysis of the truncated OXPCs. Labeled sn-2-acyl group from the long-chain OXPC was not only hydrolyzed to free fatty acid, but was preferentially transferred to diacylglycerol, in both the normal and deficient plasmas. In contrast, the acyl group from unoxidized PC was transferred only to cholesterol, showing that the specificity of LCAT is altered by OXPC. It is concluded that, while PAF-AH carries out the hydrolysis of mainly truncated OXPCs, LCAT hydrolyzes and transesterifies the long-chain OXPCs.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Saito, H.; Goldsmith, G.H. Jr.
A specific, sensitive, and reproducible radioimmunoassay for human plasma thromboplastin antecedent (PTA, factor XI) has been developed with purified PTA and monospecific rabbit antiserum. Precise measurements of PTA antigen were possible for concentrations as low as 0.3% of that in normal pooled plasma. Normal plasma contained approximately 6 ..mu..g PTA/ml. A good correlation (correlation coefficient 0.68) existed between the PTA procoagulant assays and radioimmunoassays among 50 normal adults (25 males and 25 females). PTA antigen was markedly reduced in plasma of 13 patients with congenital homozygous PTA deficiency (range <0.003-0.128 U/ml) and 9 patients with hepatic cirrhosis (0.35 +- 0.17more » U/ml), but was normal in those of 9 patients under treatment with warfarin, 8 patients with disseminated intravascular coagulation and 16 patients with other congenital clotting factor abnormalities, including prekallikrein deficiency (Fletcher trait) and high molecular weight kininogen deficiency (Fitzgerald trait).« less
Increased leukocyte adhesion to vascular endothelium in preeclampsia is inhibited by antioxidants.
Ryu, Seongho; Huppmann, Alison R; Sambangi, Nirmala; Takacs, Peter; Kauma, Scott W
2007-04-01
To test the hypothesis that plasma from women with preeclampsia increases leukocyte adhesion to vascular endothelial cells and that antioxidants inhibit this effect. Plasma from 12 women with severe preeclampsia and 12 with normal pregnancy was tested in an in vitro leukocyte-endothelium adhesion assay in the presence or absence of vitamin E, vitamin C, or N-acetylcysteine. Preeclamptic plasma significantly increased monocyte (U937 cells) and T-cell (Jurkat) adhesion to human umbilical vein (HUVEC) and microvascular endothelial cells, compared with normal pregnant plasma. The antioxidants vitamin E, vitamin C, and N-acetylcysteine significantly inhibited monocyte adhesion to HUVEC in the presence of preeclamptic but not normal pregnant plasma. Increased adhesion in response to preeclamptic plasma was not mediated through a protein kinase C (PKC) mechanism, because the PKC inhibitor bisindolylmaleimide I had no effect on adhesion in the presence of preeclamptic plasma. Severe preeclampsia is associated with increased leukocyte-endothelium adhesion and clinically useful antioxidants can inhibit this effect.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bourham, Mohamed A.; Gilligan, John G.
Safety considerations in large future fusion reactors like ITER are important before licensing the reactor. Several scenarios are considered hazardous, which include safety of plasma-facing components during hard disruptions, high heat fluxes and thermal stresses during normal operation, accidental energy release, and aerosol formation and transport. Disruption events, in large tokamaks like ITER, are expected to produce local heat fluxes on plasma-facing components, which may exceed 100 GW/m{sup 2} over a period of about 0.1 ms. As a result, the surface temperature dramatically increases, which results in surface melting and vaporization, and produces thermal stresses and surface erosion. Plasma-facing componentsmore » safety issues extends to cover a wide range of possible scenarios, including disruption severity and the impact of plasma-facing components on disruption parameters, accidental energy release and short/long term LOCA's, and formation of airborne particles by convective current transport during a LOVA (water/air ingress disruption) accident scenario. Study, and evaluation of, disruption-induced aerosol generation and mobilization is essential to characterize database on particulate formation and distribution for large future fusion tokamak reactor like ITER. In order to provide database relevant to ITER, the SIRENS electrothermal plasma facility at NCSU has been modified to closely simulate heat fluxes expected in ITER.« less
Development of a real-time system for ITER first wall heat load control
NASA Astrophysics Data System (ADS)
Anand, Himank; de Vries, Peter; Gribov, Yuri; Pitts, Richard; Snipes, Joseph; Zabeo, Luca
2017-10-01
The steady state heat flux on the ITER first wall (FW) panels are limited by the heat removal capacity of the water cooling system. In case of off-normal events (e.g. plasma displacement during H-L transitions), the heat loads are predicted to exceed the design limits (2-4.7 MW/m2). Intense heat loads are predicted on the FW, even well before the burning plasma phase. Thus, a real-time (RT) FW heat load control system is mandatory from early plasma operation of the ITER tokamak. A heat load estimator based on the RT equilibrium reconstruction has been developed for the plasma control system (PCS). A scheme, estimating the energy state for prescribed gaps defined as the distance between the last closed flux surface (LCFS)/separatrix and the FW is presented. The RT energy state is determined by the product of a weighted function of gap distance and the power crossing the plasma boundary. In addition, a heat load estimator assuming a simplified FW geometry and parallel heat transport model in the scrape-off layer (SOL), benchmarked against a full 3-D magnetic field line tracer is also presented.
Plasma Chamber and First Wall of the Ignitor Experiment^*
NASA Astrophysics Data System (ADS)
Cucchiaro, A.; Coppi, B.; Bianchi, A.; Lucca, F.
2005-10-01
The new designs of the Plasma Chamber (PC) and of the First Wall (FW) system are based on updated scenarios for vertical plasma disruption (VDE) as well as estimates for the maximum thermal wall loadings at ignition. The PC wall thickness has been optimized to reduce the deformation during the worst disruption event without sacrificing the dimensions of the plasma column. A non linear dynamic analysis of the PC has been performed on a 360^o model of it, taking into account possible toroidal asymmetries of the halo current. Radial EM loads obtained by scaling JET measurements have been also considered. The low-cycle fatigue analysis confirms that the PC is able to meet a lifetime of few thousand cycles for the most extreme combinations of magnetic fields and plasma currents. The FW, made of Molybdenum (TZM) tiles covering the entire inner surface of the PC, has been designed to withstand thermal and EM loads, both under normal operating conditions and in case of disruption. Detailed elasto-plastic structural analyses of the most (EM) loaded tile-carriers show that these are compatible with the adopted fabrication requirements. ^*Sponsored in part by ENEA of Italy and by the U.S. DOE.
Predictors of recurrence in pheochromocytoma.
Press, Danielle; Akyuz, Muhammet; Dural, Cem; Aliyev, Shamil; Monteiro, Rosebel; Mino, Jeff; Mitchell, Jamie; Hamrahian, Amir; Siperstein, Allan; Berber, Eren
2014-12-01
The recurrence rate of pheochromocytoma after adrenalectomy is 6.5-16.5%. This study aims to identify predictors of recurrence and optimal biochemical testing and imaging for detecting the recurrence of pheochromocytoma. In this retrospective study we reviewed all patients who underwent adrenalectomy for pheochromocytoma during a 14-year period at a single institution. One hundred thirty-five patients had adrenalectomy for pheochromocytoma. Eight patients (6%) developed recurrent disease. The median time from initial operation to diagnosis of recurrence was 35 months. On multivariate analysis, tumor size >5 cm was an independent predictor of recurrence. One patient with recurrence died, 4 had stable disease, 2 had progression of disease, and 1 was cured. Recurrence was diagnosed by increases in plasma and/or urinary metanephrines and positive imaging in 6 patients (75%), and by positive imaging and normal biochemical levels in 2 patients (25%). Patients with large tumors (>5 cm) should be followed vigilantly for recurrence. Because 25% of patients with recurrence had normal biochemical levels, we recommend routine imaging and testing of plasma or urinary metanephrines for prompt diagnosis of recurrence. Copyright © 2014 Elsevier Inc. All rights reserved.
Zohar, Y
1980-01-01
The use of a dorsal aorta catheterization technique to study gonadotropin secretion patterns in the rainbow trout was tested. Heparin used to flush the cannula between repetitive samplings did not have any effect on plasma GTH levels. Catheterization resulted in a slight short-term change in those levels. The gonadotropin levels returned to their initial values as soon as 30 min to 6 hrs after the operation. From then on, the GTH levels remained close to the initial values in fish exhibiting normal feeding behaviour, whereas they tended to decrease in "stressed" females which did not eat normally. The fish which adapted well to dorsal aortic catheterization did not show any changes in the diurnal pattern of GTH levels or in normal gonadal function and GTH profiles during the processes of oocyte maturation and ovulation. It is concluded that individual catheterized trout can be used advantageously for studying gonadotropin secretion patterns after a 3-day recovery period and the elimination of those fish which neither resume normal feeding nor return to initial, pre-operative GTH levels. Using this technique, it was demonstrated that hypophysial GTH release in trout with oocytes undergoing active vitellogenesis is probably effected by short-term bursts (pulses) of secretion.
El-Sherif, Ashraf Fathy
2012-07-01
During pulsed laser irradiation of dental enamel, laser-induced photoemissions result from the laser-tissue interaction through mechanisms including fluorescence and plasma formation. Fluorescence induced by non-ablative laser light interaction has been used in tissue diagnosis, but the photoemission signal accompanying higher power ablative processes may also be used to provide real-time monitoring of the laser-tissue interaction. The spectral characteristics of the photoemission signals from normal and carious tooth enamel induced by two different pulsed lasers were examined. The radiation sources compared were a high-power extra-long Q-switched Nd:YAG laser operating at a wavelength of 1,066 nm giving pulses (with pulse durations in the range 200-250 μs) in the near infrared and a free-running Er(3+)-doped ZBLAN fibre laser operating at a wavelength near 3 μm with similar pulse durations in the mid-infrared region. The photoemission spectra produced during pulsed laser irradiation of enamel samples were recorded using a high-resolution spectrometer with a CCD array detector that enabled an optical resolution as high as 0.02 nm (FWHM). The spectral and time-dependence of the laser-induced photoemission due to thermal emission and plasma formation were detected during pulsed laser irradiation of hard tissues and were used to distinguish between normal and carious teeth. The use of these effects to distinguish between hard and soft biological tissues during photothermal ablation with a pulsed Nd:YAG laser or an Er fibre laser appears feasible. The real-time spectrally resolved phototransmission spectrum produced during pulsed Nd:YAG laser irradiation of human tooth enamel samples was recorded, with a (normalized) relative transmission coefficient of 1 (100%) for normal teeth and 0.6 (60%) for the carious teeth. The photoemission signal accompanying ablative events may also be used to provide real-time monitoring of the laser-tissue interaction.
The Galileo plasma wave investigation
NASA Technical Reports Server (NTRS)
Gurnett, D. A.; Kurth, W. S.; Shaw, R. R.; Roux, A.; Gendrin, R.; Kennel, C. F.; Scarf, F. L.; Shawhan, S. D.
1992-01-01
The purpose of the Galileo plasma wave investigation is to study plasma waves and radio emissions in the magnetosphere of Jupiter. The plasma wave instrument uses an electric dipole antenna to detect electric fields, and two search coil magnetic antennas to detect magnetic fields. The frequency range covered is 5 Hz to 5.6 MHz for electric fields and 5 Hz to 160 kHz for magnetic fields. Low time-resolution survey spectrums are provided by three on-board spectrum analyzers. In the normal mode of operation the frequency resolution is about 10 percent, and the time resolution for a complete set of electric and magnetic field measurements is 37.33 s. High time-resolution spectrums are provided by a wideband receiver. The wideband receiver provides waveform measurements over bandwidths of 1, 10, and 80 kHz. Compared to previous measurements at Jupiter this instrument has several new capabilities. These new capabilities include (1) both electric and magnetic field measurements to distinguish electrostatic and electromagnetic waves, (2) direction finding measurements to determine source locations, and (3) increased bandwidth for the wideband measurements.
Matuszczak, E; Sankiewicz, A; Debek, W; Gorodkiewicz, E; Milewski, R; Hermanowicz, A
2018-01-01
The aim of this study was to determinate the immunoproteasome concentration in the blood plasma of children with appendicitis, and its correlation with circulating proteasome and ubiquitin carboxyl-terminal hydrolase L1 (UCHL1). Twenty-seven children with acute appendicitis, managed at the Paediatric Surgery Department, were included randomly into the study (age 2 years 9 months up to 14 years, mean age 9·5 ± 1 years). There were 10 girls and 17 boys; 18 healthy, age-matched subjects, admitted for planned surgeries served as controls. Mean concentrations of immunoproteasome, 20S proteasome and UCHL1 in the blood plasma of children with appendicitis before surgery 24 h and 72 h after the appendectomy were higher than in the control group. The immunoproteasome, 20S proteasome and UCHL1 concentrations in the blood plasma of patients with acute appendicitis were highest before surgery. The immunoproteasome, 20S proteasome and UCHL1 concentration measured 24 and 72 h after the operation decreased slowly over time and still did not reach the normal range (P < 0·05). There was no statistical difference between immunoproteasome, 20S proteasome and UCHL1 concentrations in children operated on laparoscopically and children after classic appendectomy. The immunoproteasome concentration may reflect the metabolic response to acute state inflammation, and the process of gradual ebbing of the inflammation may thus be helpful in the assessment of the efficacy of treatment. The method of operation - classic open appendectomy or laparoscopic appendectomy - does not influence the general trend in immunoproteasome concentration in children with appendicitis. © 2017 British Society for Immunology.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Moroz, L.A.; MacLean, L.D.; Langleben, D.
1986-09-15
Fibrinolytic activities of whole blood and plasma were determined by /sup 125/I-fibrin radiometric assay in 16 normal subjects, and in 11 patients with systemic lupus erythematosus (SLE), 14 with progressive systemic sclerosis (PSS), 23 with venous thromboembolic disease, and 20 patients awaiting elective surgery. Mean whole blood and plasma activities for patients with PSS, and for those awaiting elective surgery, were similar to normal values, as was the mean plasma activity in patients with SLE. However, mean whole blood activity in SLE was significantly decreased compared with normals (p less than 0.05), with mean plasma activity accounting for 44% ofmore » mean whole blood activity (compared with 17% in normal subjects), representing a 67% decrease in mean calculated cellular phase activity in SLE, when compared with normals. Since the numbers of cells (neutrophils, monocytes) possibly involved in cellular activity were not decreased, the findings suggest a functional defect in fibrinolytic activity of one or more blood cell types in SLE. An additional finding was the participation of the cellular phase as well as the well-known plasma phase of blood in the fibrinolytic response to thromboembolism.« less
Radioimmunoassay of human high molecular weight kininogen in normal and deficient plasmas
DOE Office of Scientific and Technical Information (OSTI.GOV)
Proud, D.; Pierce, J.V.; Pisano, J.J.
1980-04-01
An RIA for human HMW kininogen, capable of detecting 150 pg of antigen, has been developed. Antibody to HMW kininogen was purified by immunoaffinity chromatography, and double-antibody precipitation was used to separate free and bound antigen. Of the LMW kininogens only one of the forms tested (B3.2) showed significant cross-reaction (2%). Bradykinin and human plasma kallikrein both showed no cross-reaction, and monkey HMW kininogen showed identity to the human antigen. Intraassay and interassay coefficients of variation were 2 and 1.5%, respectively. Recovery of HMW kininogen added to 6 plasmas was 97.7% +- 1.8%. Assay of 17 normal plasmas gave amore » level of 90.8 +- 2.5 ..mu..g/ml HMW kininogen (mean +- S.E.M.). A bioassay of the samples, based on specific release of kinin by purified plasma kallikrein, yielded a level of 90.2 +- 2.8 ..mu..g/ml HMW kininogen (r = 0.83, p < 0.001). In neither assay was any significant sex difference observed. No evidence of any antigenic fragments was seen upon gel filtration of normal plasmas. RIA measurements were also performed on seven plasmas reportedly deficient in HMW kininogen. Williams, Dayton, San Francisco, and Flaujeac plasmas all showed no significant cross-reaction, whereas Fitzgerald, Reid, and Detroit plasmas showed 1.0, 2.5, and 3.5% of normal antigenic levels, respectively. This sensitive, convenient method should facilitate studies on the role of the kallikrein-kinin system in health and disease.« less
Öngöz Dede, F; Bozkurt Doğan, Ş; Balli, U; Avci, B; Durmuşlar, M C; Baratzade, T
2016-12-01
The purpose of this study was to investigate the effects of obesity on reduced and oxidized glutathione (GSH and GSSG) levels in the gingival crevicular fluid, plasma and saliva of patients with chronic periodontitis and to evaluate the changes after nonsurgical periodontal therapy. The study included 60 patients: 30 patients with chronic periodontitis (15 obese patients and 15 normal weight patients) and 30 healthy control subjects (15 obese patients and 15 normal weight patients). Gingival crevicular fluid, plasma and saliva samples were collected, and clinical periodontal measurements were recorded at baseline and at the first month after periodontal therapy from patients with chronic periodontitis. GSH and GSSG levels were analyzed with spectrophotometry. The GSH levels in the plasma, saliva and gingival crevicular fluid in obese individuals with chronic periodontitis were lower than in normal weight individuals at baseline (p < 0.01). There was a significant difference in the GSH/GSSG ratio in plasma and gingival crevicular fluid between the obese and normal weight groups at baseline (p < 0.01). The GSH levels in plasma, gingival crevicular fluid and saliva were significantly increased in both chronic periodontitis groups after nonsurgical periodontal therapy (p < 0.01). A significant positive correlation was found between GSH levels in saliva, plasma and gingival crevicular fluid in all groups (p < 0.001). The study revealed that obesity in patients with chronic periodontitis is associated with decreased GSH levels and the GSH/GSSG ratio. Moreover, nonsurgical periodontal therapy may be helpful for improvement in glutathione values in obese and normal weight individuals with chronic periodontitis. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Dysmegakaryocytopoiesis and maintaining platelet count in patients with plasma cell neoplasm.
Mair, Yasmin; Zheng, Yan; Cai, Donghong
2013-05-01
Dysmegakaryocytopoiesis in patients with the plasma cell neoplasm (PCN) is rarely discussed in the literature. The puzzling phenomenon, which PCN patients maintaining normal platelet count even when the marrow is mostly replaced by plasma cells, is hardly explored. This study was aimed to determine the frequency of dysmegakaryocytopoiesis in PCN and the relationships between bone marrow (BM) plasma cell percentage, plasma cell immunomarkers, the severity of dysmegakaryocytopoiesis, and peripheral blood platelet count in PCN. We randomly selected 16 cases of PCN, among which 4 were with monoclonal gammopathy of undetermined significance and 12 were with plasma cell myeloma. OUR STUDY SHOWED THAT: (1) Dysmegakaryocytopoiesis was present in all the selected cases of PCN and its severity was not correlated with the percentage of the plasma cells in BM; (2) almost all patients maintained normal platelet count even when BM was mostly replaced by plasma cells; (3) immunomarkers of the neoplastic plasma cells were not associated with dysmegakaryocytopoiesis or maintaining of platelet count. The possible mechanisms behind dysmegakaryocytopoiesis and maintaining of platelet count were also discussed. Despite the universal presence of dysmegakaryocytopoiesis in PCN, the platelet count is maintained at normal range.
Real-Time Clinical Decision Support Decreases Inappropriate Plasma Transfusion.
Shah, Neil; Baker, Steven A; Spain, David; Shieh, Lisa; Shepard, John; Hadhazy, Eric; Maggio, Paul; Goodnough, Lawrence T
2017-08-01
To curtail inappropriate plasma transfusions, we instituted clinical decision support as an alert upon order entry if the patient's recent international normalized ratio (INR) was 1.7 or less. The alert was suppressed for massive transfusion and within operative or apheresis settings. The plasma order was automatically removed upon alert acceptance while clinical exception reasons allowed for continued transfusion. Alert impact was studied comparing a 7-month control period with a 4-month intervention period. Monthly plasma utilization decreased 17.4%, from a mean ± SD of 3.40 ± 0.48 to 2.82 ± 0.6 plasma units per hundred patient days (95% confidence interval [CI] of difference, -0.1 to 1.3). Plasma transfused below an INR of 1.7 or less decreased from 47.6% to 41.6% (P = .0002; odds ratio, 0.78; 95% CI, 0.69-0.89). The alert recommendation was accepted 33% of the time while clinical exceptions were chosen in the remaining cases (active bleeding, 31%; other clinical indication, 33%; and apheresis, 2%). Alert acceptance rate varied significantly among different provider specialties. Clinical decision support can help curtail inappropriate plasma use but needs to be part of a comprehensive strategy including audit and feedback for comprehensive, long-term changes. © American Society for Clinical Pathology, 2017. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com
A contaminant-free assessment of Endogenous Retroviral RNA in human plasma
Karamitros, Timokratis; Paraskevis, Dimitrios; Hatzakis, Angelos; Psichogiou, Mina; Elefsiniotis, Ioannis; Hurst, Tara; Geretti, Anna-Maria; Beloukas, Apostolos; Frater, John; Klenerman, Paul; Katzourakis, Aris; Magiorkinis, Gkikas
2016-01-01
Endogenous retroviruses (ERVs) comprise 6–8% of the human genome. HERVs are silenced in most normal tissues, up-regulated in stem cells and in placenta but also in cancer and HIV-1 infection. Crucially, there are conflicting reports on detecting HERV RNA in non-cellular clinical samples such as plasma that suggest the study of HERV RNA can be daunting. Indeed, we find that the use of real-time PCR in a quality assured clinical laboratory setting can be sensitive to low-level proviral contamination. We developed a mathematical model for low-level contamination that allowed us to design a laboratory protocol and standard operating procedures for robust measurement of HERV RNA. We focus on one family, HERV-K HML-2 (HK2) that has been most recently active even though they invaded our ancestral genomes almost 30 millions ago. We extensively validated our experimental design on a model cell culture system showing high sensitivity and specificity, totally eliminating the proviral contamination. We then tested 236 plasma samples from patients infected with HIV-1, HCV or HBV and found them to be negative. The study of HERV RNA for human translational studies should be performed with extensively validated protocols and standard operating procedures to control the widespread low-level human DNA contamination. PMID:27640347
NASA Astrophysics Data System (ADS)
Eidietis, N. W.; Choi, W.; Hahn, S. H.; Humphreys, D. A.; Sammuli, B. S.; Walker, M. L.
2018-05-01
A finite-state off-normal and fault response (ONFR) system is presented that provides the supervisory logic for comprehensive disruption avoidance and machine protection in tokamaks. Robust event handling is critical for ITER and future large tokamaks, where plasma parameters will necessarily approach stability limits and many systems will operate near their engineering limits. Events can be classified as off-normal plasmas events, e.g. neoclassical tearing modes or vertical displacements events, or faults, e.g. coil power supply failures. The ONFR system presented provides four critical features of a robust event handling system: sequential responses to cascading events, event recovery, simultaneous handling of multiple events and actuator prioritization. The finite-state logic is implemented in Matlab®/Stateflow® to allow rapid development and testing in an easily understood graphical format before automated export to the real-time plasma control system code. Experimental demonstrations of the ONFR algorithm on the DIII-D and KSTAR tokamaks are presented. In the most complex demonstration, the ONFR algorithm asynchronously applies ‘catch and subdue’ electron cyclotron current drive (ECCD) injection scheme to suppress a virulent 2/1 neoclassical tearing mode, subsequently shuts down ECCD for machine protection when the plasma becomes over-dense, and enables rotating 3D field entrainment of the ensuing locked mode to allow a safe rampdown, all in the same discharge without user intervention. When multiple ONFR states are active simultaneously and requesting the same actuator (e.g. neutral beam injection or gyrotrons), actuator prioritization is accomplished by sorting the pre-assigned priority values of each active ONFR state and giving complete control of the actuator to the state with highest priority. This early experience makes evident that additional research is required to develop an improved actuator sharing protocol, as well as a methodology to minimize the number and topological complexity of states as the finite-state ONFR system is scaled to a large, highly constrained device like ITER.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Eidietis, N. W.; Choi, W.; Hahn, S. H.
A finite-state off-normal and fault response (ONFR) system is presented that provides the supervisory logic for comprehensive disruption avoidance and machine protection in tokamaks. Robust event handling is critical for ITER and future large tokamaks, where plasma parameters will necessarily approach stability limits and many systems will operate near their engineering limits. Events can be classified as off-normal plasmas events, e.g. neoclassical tearing modes or vertical displacements events, or faults, e.g. coil power supply failures. The ONFR system presented provides four critical features of a robust event handling system: sequential responses to cascading events, event recovery, simultaneous handling of multiplemore » events and actuator prioritization. The finite-state logic is implemented in Matlab*/Stateflow* to allow rapid development and testing in an easily understood graphical format before automated export to the real-time plasma control system code. Experimental demonstrations of the ONFR algorithm on the DIII-D and KSTAR tokamaks are presented. In the most complex demonstration, the ONFR algorithm asynchronously applies “catch and subdue” electron cyclotron current drive (ECCD) injection scheme to suppress a virulent 2/1 neoclassical tearing mode, subsequently shuts down ECCD for machine protection when the plasma becomes over-dense, and enables rotating 3D field entrainment of the ensuing locked mode to allow a safe rampdown, all in the same discharge without user intervention. When multiple ONFR states are active simultaneously and requesting the same actuator (e.g. neutral beam injection or gyrotrons), actuator prioritization is accomplished by sorting the pre-assigned priority values of each active ONFR state and giving complete control of the actuator to the state with highest priority. This early experience makes evident that additional research is required to develop an improved actuator sharing protocol, as well as a methodology to minimize the number and topological complexity of states as the finite-state ONFR system is scaled to a large, highly constrained device like ITER.« less
Eidietis, N. W.; Choi, W.; Hahn, S. H.; ...
2018-03-29
A finite-state off-normal and fault response (ONFR) system is presented that provides the supervisory logic for comprehensive disruption avoidance and machine protection in tokamaks. Robust event handling is critical for ITER and future large tokamaks, where plasma parameters will necessarily approach stability limits and many systems will operate near their engineering limits. Events can be classified as off-normal plasmas events, e.g. neoclassical tearing modes or vertical displacements events, or faults, e.g. coil power supply failures. The ONFR system presented provides four critical features of a robust event handling system: sequential responses to cascading events, event recovery, simultaneous handling of multiplemore » events and actuator prioritization. The finite-state logic is implemented in Matlab*/Stateflow* to allow rapid development and testing in an easily understood graphical format before automated export to the real-time plasma control system code. Experimental demonstrations of the ONFR algorithm on the DIII-D and KSTAR tokamaks are presented. In the most complex demonstration, the ONFR algorithm asynchronously applies “catch and subdue” electron cyclotron current drive (ECCD) injection scheme to suppress a virulent 2/1 neoclassical tearing mode, subsequently shuts down ECCD for machine protection when the plasma becomes over-dense, and enables rotating 3D field entrainment of the ensuing locked mode to allow a safe rampdown, all in the same discharge without user intervention. When multiple ONFR states are active simultaneously and requesting the same actuator (e.g. neutral beam injection or gyrotrons), actuator prioritization is accomplished by sorting the pre-assigned priority values of each active ONFR state and giving complete control of the actuator to the state with highest priority. This early experience makes evident that additional research is required to develop an improved actuator sharing protocol, as well as a methodology to minimize the number and topological complexity of states as the finite-state ONFR system is scaled to a large, highly constrained device like ITER.« less
D’Alessandro, Angelo; Moore, Hunter B; Moore, Ernest E; Wither, Matthew J.; Nemkov, Travis; Morton, Alexander P; Gonzalez, Eduardo; Chapman, Michael P; Fragoso, Miguel; Slaughter, Anne; Sauaia, Angela; Silliman, Christopher C; Hansen, Kirk C; Banerjee, Anirban
2016-01-01
The use of aggressive crystalloid resuscitation to treat hypoxemia, hypovolemia and nutrient deprivation promoted by massive blood loss may lead to the development of the blood vicious cycle of acidosis, hypothermia, and coagulopathy and, utterly, death. Metabolic acidosis is one of the many metabolic derangements triggered by severe trauma/hemorrhagic shock, also including enhanced proteolysis, lipid mobilization, as well as traumatic diabetes. Appreciation of the metabolic benefit of plasma first resuscitation is an important concept. Plasma resuscitation has been shown to correct hyperfibrinolysis secondary to severe hemorrhage better than normal saline. Here we hypothesize that plasma first resuscitation corrects metabolic derangements promoted by severe hemorrhage better than resuscitation with normal saline. Ultra-high-performance liquid chromatography-mass spectrometry-based metabolomics analyses were performed to screen plasma metabolic profiles upon shock and resuscitation with either platelet-free plasma or normal saline in a rat model of severe hemorrhage. Of the 251 metabolites that were monitored, 101 were significantly different in plasma vs normal saline resuscitated rats. Plasma resuscitation corrected lactate acidosis by promoting glutamine/amino acid catabolism and purine salvage reactions. Plasma first resuscitation may benefit critically injured trauma patients by relieving the lactate burden and promoting other non-clinically measured metabolic changes. In the light of our results, we propose that plasma resuscitation may promote fueling of mitochondrial metabolism, through the enhancement of glutaminolysis/amino acid catabolism and purine salvage reactions. The treatment of trauma patients in hemorrhagic shock with plasma first resuscitation is likely not only to improve coagulation, but also to promote substrate-specific metabolic corrections. PMID:26863033
NASA Astrophysics Data System (ADS)
Brennan, D. P.; Finn, J. M.
2014-10-01
Feedback stabilization of magnetohydrodynamic (MHD) modes in a tokamak is studied in a cylindrical model with a resistive wall, plasma resistivity, viscosity, and toroidal rotation. The control is based on a linear combination of the normal and tangential components of the magnetic field just inside the resistive wall. The feedback includes complex gain, for both the normal and for the tangential components, and it is known that the imaginary part of the feedback for the former is equivalent to plasma rotation [J. M. Finn and L. Chacon, Phys. Plasmas 11, 1866 (2004)]. The work includes (1) analysis with a reduced resistive MHD model for a tokamak with finite β and with stepfunction current density and pressure profiles, and (2) computations with a full compressible visco-resistive MHD model with smooth decreasing profiles of current density and pressure. The equilibria are stable for β = 0 and the marginal stability values βrp,rw < βrp,iw < βip,rw < βip,iw (resistive plasma, resistive wall; resistive plasma, ideal wall; ideal plasma, resistive wall; and ideal plasma, ideal wall) are computed for both models. The main results are: (a) imaginary gain with normal sensors or plasma rotation stabilizes below βrp,iw because rotation suppresses the diffusion of flux from the plasma out through the wall and, more surprisingly, (b) rotation or imaginary gain with normal sensors destabilizes above βrp,iw because it prevents the feedback flux from entering the plasma through the resistive wall to form a virtual wall. A method of using complex gain Gi to optimize in the presence of rotation in this regime with β > βrp,iw is presented. The effect of imaginary gain with tangential sensors is more complicated but essentially destabilizes above and below βrp,iw.
NASA Astrophysics Data System (ADS)
Reusch, Joshua
2017-10-01
A major goal of the spherical tokamak research program is accessing a state of low internal inductance li, high elongation κ, high toroidal and normalized beta (βt and βN) , and low collisionality without solenoidal current drive. A new local helicity injection (LHI) system in the lower divertor region of the ultra-low aspect ratio Pegasus ST provides non-solenoidally driven plasmas that exhibit most of these characteristics. LHI utilizes compact, edge-localized current sources (Ainj 4 cm2, Iinj 8 kA, Vinj 1.5 kV) for plasma startup and sustainment, and can sustain more than 200 kA of plasma current. Plasma growth via LHI is enhanced by a transition from a regime of high kink-like MHD activity to one of reduced MHD activity at higher frequencies and presumably shorter wavelengths. The strong edge current drive provided by LHI results in a hollow current density profile with low li. The low aspect ratio (R0 / a 1.2) of Pegasus allows ready access to high κ and MHD stable operation at very high normalized plasma currents (IN =Ip /aBT> 15). Thomson scattering measurements indicate Te 100 eV and ne 1 ×19 m-3. The impurity Ti evolution is correlated in time with high frequency magnetic fluctuations, implying substantial reconnection ion heating is driven by the applied helicity injection. Doppler spectroscopy indicates Ti >=Te and that the anomalous ion heating scales consistently with two fluid reconnection theory. Taken together, these features provide access to very high βt plasmas. Equilibrium analyses indicate βt up to 100% and βN 6.5 is achieved. At increasingly low BT, the discharge disrupts at the no-wall ideal stability limit. In these high βt discharges, a minimum |B| well forms over 50% of the plasma volume. This unique magnetic configuration may be of interest for testing predictions of stabilizing drift wave turbulence and/or improving energetic particle confinement. This work supported by US DOE Grants DE-FG02-96ER54375 and DE-SC0006928.
NASA Astrophysics Data System (ADS)
Bae, Sung Eun
Mares susceptible to persistent mating-induced endometritis (PMIE) accumulate intrauterine fluid after mating. One of the factors causing delayed uterine clearance is thought to be impaired uterine contractility. Oxytocin is central in controlling myometrial contractility. The objective of the present study was to describe peripheral oxytocin release during estrus and in the early postovulatory period in reproductively-normal mares and to compare the baseline circulating oxytocin concentrations in reproductively-normal mares and mares with PMIE. Blood samples were collected from reproductively-normal mares (n=5) from day -5 of estrus to day 2 postovulation and every 5 min for 30 min from reproductively-normal mares (n=5) and mares with PMIE (n=5) on day 3 of estrus. Pulsatile secretion of oxytocin was observed in all mares. Mean plasma oxytocin concentrations were significantly higher (P<0.05) in estrus (day -5 to day -2) than on the day of ovulation (day 0). After ovulation, plasma oxytocin concentrations tended to increase. On day 3 of estrus, plasma oxytocin concentrations were significantly higher (P<0.01) in reproductively-normal mares than in mares with PMIE. The results showed there is a significant difference in plasma oxytocin concentrations between mares to PMIE. The low plasma oxytocin concentrations in mares with PMIE may contribute to predisposing factors in their poor uterine clearance in these mares.
Linear non-normality as the cause of nonlinear instability in LAPD
NASA Astrophysics Data System (ADS)
Friedman, Brett; Carter, Troy; Umansky, Maxim
2013-10-01
A BOUT + + simulation using a Braginskii fluid model reproduces drift-wave turbulence in LAPD with high qualitative and quantitative agreement. The turbulent fluctuations in the simulation sustain themselves through a nonlinear instability mechanism that injects energy into k|| = 0 fluctuations despite the fact that all of the linear eigenmodes at k|| = 0 are stable. The reason for this is the high non-orthogonality of the eigenmodes caused by the non-normality of the linear operator, which is common in fluid and plasma models that contain equilibrium gradients. While individual stable eigenmodes must decay when acted upon by their linear operator, the sum of the eigenmodes may grow transiently with initial algebraic time dependence. This transient growth can inject energy into the system, and the nonlinearities can remix the eigenmode amplitudes to self-sustain the growth. Such a mechanism also acts in subcritical neutral fluid turbulence, and the self-sustainment process is quite similar, indicating the universality of this nonlinear instability.
Sizonenko, P C; Rabinovitch, A; Schneider, P; Paunier, L; Wollheim, C B; Zahnd, G
1975-09-01
The effects of intravenous infusion of arginine (20 g/m2) after an overnight fast on plasma immunoreactive growth hormone (GH), insulin (IRI), and glucagon (IRG), and blood glucose were examined in five groups of children and adolescents: 10 normal individuals, 18 with idiopathic short stature, 6 with isolated growth hormone deficiency, 8 with panhypopituitarism, and 6 with anorexia nervosa. The mean fasting plasma GH concentration was significantly elevated in the group with anorexia nervosa (P less than 0.05), and similar to the value for the normal group in all other groups. After arginine infusion, four- to sixfold increases of plasma GH were observed in the normal children, and similar increases were seen in those with idiopathic short stature as well as in those with anorexia nervosa; whereas, in the children with isolated growth hormone deficiency or panhypopituitarism, there was no significant increase in plasma GH. Fasting blood glucose concentrations were significantly lower than normal in subjects with isolated growth hormone deficiency (P less than 0.05), panhypopituitarism (P less than 0.001), and anorexia nervosa (P less than 0.001), whereas fasting plasma IRI and IRG concentrations were similar to the values in the normal group. Plasma IRI increased eightfold at the end of the 30-min arginine infusion in the normal subjects; the increase was slightly but not significantly less in those with idiopathic short stature, and significantly less in those with isolated growth hormone deficiency (P less than 0.05), panhypopituitarism (P less than 0.001), and anorexia nervosa (P less than 0.05). Arginine infusion resulted in two- to threefold increases of plasma IRG in the normal group, and similar increases were observed in all of the other groups tested. These results suggest that whereas pancreatic beta cell responsiveness may be deficient in children and adolescents with isolated growth hormone deficiency, panhypopituitarism, or anorexia nervosa, pancreatic alpha cell responsiveness, to arginine at least, appears to be intact under these conditions.
Design requirements for plasma facing materials in ITER
NASA Astrophysics Data System (ADS)
Matera, R.; Federici, G.; ITER Joint Central Team
1996-10-01
After the official approval of the Interim Design Report, the ITER project enters the final phase of the EDA. With the definition of the design requirements of the high heat flux components, the structural and armor materials' working domain is better specified, allowing to focus the R & D program on the most critical issues and to orient the design of divertor and first wall components towards those concepts which potentially have a better chance to withstand normal and off-normal operating conditions. Among the latter, slow, high-power, high recycling transient are at present driving the design of high heat flux components. Examples of possible design solution under experimental validation in the R & D program are presented and discussed in this paper.
Describing hypoglycemia--definition or operational threshold?
Rozance, Paul J; Hay, William W
2010-05-01
Severe glucose deficiency leads to cerebral energy failure, impaired cardiac performance, muscle weakness, glycogen depletion, and diminished glucose production. Thus, maintenance of glucose delivery to all organs is an essential physiological function. Normal term infants have sufficient alternate energy stores and capacity for glucose production from glycogenolysis and gluconeogenesis to ensure normal glucose metabolism during the transition to extrauterine life and early neonatal period. Milk feedings particularly enhance glucose homeostasis. Energy sources often are low in preterm and growth restricted infants, who are especially vulnerable to glucose deficiency. Plasma glucose concentration is the only practical measure of glucose sufficiency, but by itself is a very limited guide. Key to preventing complications from glucose deficiency is to identify infants at risk, promote early and frequent feedings, normalize glucose homeostasis, measure glucose concentrations early and frequently in infants at risk, and treat promptly when glucose deficiency is marked and symptomatic. 2010 Elsevier Ireland Ltd. All rights reserved.
Describing hypoglycemia - definition or operational threshold?
Rozance, Paul J.; Hay, William W.
2010-01-01
Severe glucose deficiency leads to cerebral energy failure, impaired cardiac performance, muscle weakness, glycogen depletion, and diminished glucose production. Thus, maintenance of glucose delivery to all organs is an essential physiological function. Normal term infants have sufficient alternate energy stores and capacity for glucose production from glycogenolysis and gluconeogenesis to ensure normal glucose metabolism during the transition to extrauterine life and early neonatal period. Milk feedings particularly enhance glucose homeostasis. Energy sources often are low in preterm and growth restricted infants, who are especially vulnerable to glucose deficiency. Plasma glucose concentration is the only practical measure of glucose sufficiency, but by itself is a very limited guide. Key to preventing complications from glucose deficiency is to identify infants at risk, promote early and frequent feedings, normalize glucose homeostasis, measure glucose concentrations early and frequently in infants at risk, and treat promptly when glucose deficiency is marked and symptomatic. PMID:20554129
Loda, M; Clowes, G H; Dinarello, C A; George, B C; Lane, B; Richardson, W
1984-08-01
Accelerated release of amino acids from muscle and their uptake for protein synthesis by liver and other visceral tissues are characteristic of trauma or sepsis. Experimentally, this response is induced by interleukin-1 (IL-1) generated by activated macrophages in vitro. However, IL-1 has not been demonstrated in human blood. A small 4000-dalton peptide recently isolated from plasma of patients with sepsis and trauma induces muscle proteolysis and is called "proteolysis-inducing factor" (PIF). To test whether this agent has the ability also to induce hepatic protein synthesis, a series of animal experiments and clinical observations were undertaken. The structural and secretory (acute-phase reactants) in vitro protein synthesis in livers of normal rats injected intraperitoneally with IL-1 or PIF was significantly greater than that of normal rats or those injected with Ringer's lactate (p less than 0.01). In patients with sepsis and trauma the central plasma clearance rate of amino acids, a measure of visceral (principally hepatic) amino acid uptake, was elevated and correlated with the rates of protein synthesis in incubated liver slices obtained by biopsy at operation from the same patients (p less than 0.05). Both in vivo measured central plasma clearance rate of amino acids and in vitro measured hepatic protein synthesis correlated with plasma levels of PIF in the same patients (p less than 0.01 and p less than 0.05, respectively). We conclude that since PIF, and not IL-1, is present in human plasma and both are produced by activated macrophages, PIF seems to be the stable circulating cleavage product of IL-1, which induces not only muscle proteolysis but also hepatic protein synthesis, principally in the form of acute-phase reactants during infection and other states in which inflammation is present.
Di Bonito, Procolo; Licenziati, Maria Rosaria; Baroni, Marco Giorgio; Congiu, Tiziana; Incani, Michela; Iannuzzi, Arcangelo; Maffeis, Claudio; Perrone, Laura; Valerio, Giuliana; Del Giudice, Emanuele Miraglia
2014-08-01
To evaluate normoglycemic overweight/obese (Ow/Ob) children whose post-load plasma glucose (2hPG) cut-point may be significantly associated with cardiometabolic risk factors (CMRFs) and whether this cut-point predicts preclinical signs of organ damage. One thousand seven hundred and thrity four normoglycemic Ow/Ob children were stratified into quintiles of 2hPG, the sixth group was constituted by 101 children with impaired glucose tolerance (IGT). Moving from the lower quintiles of 2hPG to IGT, the groups differed for Prepubertal stage, BMI, fasting PG, insulin levels, blood pressure, and lipids. To evaluate the best cut-off of 2hPG related to CMRFs, the area under the receiver operating characteristic curve and the Youden's index was calculated. Insulin resistance, high blood pressure, and high triglyceride/HDL-C ratio were associated with a 2hPG cut-off of 110 mg/dl. Children with 2hPG ≥110 mg/dl showed 1.3-3.2 fold higher risk to have high levels of ALT (as surrogate of nonalcoholic fatty liver disease) or increased carotid intima-media thickness. This study, performed in a large cohort of Ow/Ob children, shows that an atherogenic risk profile and preclinical signs of organ damage are associated with post-challenge elevations in plasma glucose still considered in the high normal range. Copyright © 2014 The Obesity Society.
Computational hydrodynamics and optical performance of inductively-coupled plasma adaptive lenses
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mortazavi, M.; Urzay, J., E-mail: jurzay@stanford.edu; Mani, A.
2015-06-15
This study addresses the optical performance of a plasma adaptive lens for aero-optical applications by using both axisymmetric and three-dimensional numerical simulations. Plasma adaptive lenses are based on the effects of free electrons on the phase velocity of incident light, which, in theory, can be used as a phase-conjugation mechanism. A closed cylindrical chamber filled with Argon plasma is used as a model lens into which a beam of light is launched. The plasma is sustained by applying a radio-frequency electric current through a coil that envelops the chamber. Four different operating conditions, ranging from low to high powers andmore » induction frequencies, are employed in the simulations. The numerical simulations reveal complex hydrodynamic phenomena related to buoyant and electromagnetic laminar transport, which generate, respectively, large recirculating cells and wall-normal compression stresses in the form of local stagnation-point flows. In the axisymmetric simulations, the plasma motion is coupled with near-wall axial striations in the electron-density field, some of which propagate in the form of low-frequency traveling disturbances adjacent to vortical quadrupoles that are reminiscent of Taylor-Görtler flow structures in centrifugally unstable flows. Although the refractive-index fields obtained from axisymmetric simulations lead to smooth beam wavefronts, they are found to be unstable to azimuthal disturbances in three of the four three-dimensional cases considered. The azimuthal striations are optically detrimental, since they produce high-order angular aberrations that account for most of the beam wavefront error. A fourth case is computed at high input power and high induction frequency, which displays the best optical properties among all the three-dimensional simulations considered. In particular, the increase in induction frequency prevents local thermalization and leads to an axisymmetric distribution of electrons even after introduction of spatial disturbances. The results highlight the importance of accounting for spatial effects in the numerical computations when optical analyses of plasma lenses are pursued in this range of operating conditions.« less
NASA Astrophysics Data System (ADS)
Guo, W. F.; Gong, X. Z.; Huang, J.; Ren, Q. L.; Qian, J. P.; Ding, S. Y.; Pan, C. K.; Li, G. Q.; Xia, T. Y.; Garofalo, A. M.; Lao, L.; Hyatt, A.; Ferron, J.; Meneghini, O.; Liu, Y. Q.; McClenaghan, J.; Holcomb, C. T.
2017-10-01
The high poloidal beta scenario with plasma current IP 600 kA and large-radius internal transport barrier (ITB) on DIII-D is subject to n =1 MHD kink modes when the current profile becomes very broad at internal inductance values li 0.5-0.6. It is desirable to extend this scenario to higer plasma current ( 1 MA) for highernormalized fusionperformance. However, higher current at constant normalized beta, ?N 3, would reducethe poloidal bet, ?P, below the threshold for ITB sustainment, observed at ?P 1.9. Thus, to avoid loss of the IT, ?N?? must be increased together with IP while avoiding the kink instability. MHD analysis is presented that explains possible paths to high ?N stability limit for the kink mode in tis scenario. Work supported by National Magnetic Confinement Fusion Program of Chin under 2015GB110001 and 2015GB102000 - National Natural Science Foundation of China under Grant No. 1147521 and by US DOE under DE-FC02-04ER54698.
Antoine, Daniel J; Dear, James W; Lewis, Philip Starkey; Platt, Vivien; Coyle, Judy; Masson, Moyra; Thanacoody, Ruben H; Gray, Alasdair J; Webb, David J; Moggs, Jonathan G; Bateman, D Nicholas; Goldring, Christopher E; Park, B Kevin
2013-01-01
Acetaminophen overdose is a common reason for hospital admission and the most frequent cause of hepatotoxicity in the Western world. Early identification would facilitate patient-individualized treatment strategies. We investigated the potential of a panel of novel biomarkers (with enhanced liver expression or linked to the mechanisms of toxicity) to identify patients with acetaminophen-induced acute liver injury (ALI) at first presentation to the hospital when currently used markers are within the normal range. In the first hospital presentation plasma sample from patients (n = 129), we measured microRNA-122 (miR-122; high liver specificity), high mobility group box-1 (HMGB1; marker of necrosis), full-length and caspase-cleaved keratin-18 (K18; markers of necrosis and apoptosis), and glutamate dehydrogenase (GLDH; marker of mitochondrial dysfunction). Receiver operator characteristic curve analysis and positive/negative predictive values were used to compare sensitivity to report liver injury versus alanine transaminase (ALT) and International Normalized Ratio (INR). In all patients, biomarkers at first presentation significantly correlated with peak ALT or INR. In patients presenting with normal ALT or INR, miR-122, HMGB1, and necrosis K18 identified the development of liver injury (n = 15) or not (n = 84) with a high degree of accuracy and significantly outperformed ALT, INR, and plasma acetaminophen concentration for the prediction of subsequent ALI (n = 11) compared with no ALI (n = 52) in patients presenting within 8 hours of overdose. Conclusion: Elevations in plasma miR-122, HMGB1, and necrosis K18 identified subsequent ALI development in patients on admission to the hospital, soon after acetaminophen overdose, and in patients with ALTs in the normal range. The application of such a biomarker panel could improve the speed of clinical decision-making, both in the treatment of ALI and the design/execution of patient-individualized treatment strategies. PMID:23390034
Maes, M; van West, D; De Vos, N; Westenberg, H; Van Hunsel, F; Hendriks, D; Cosyns, P; Scharpé, S
2001-01-01
There is some evidence that hormonal and serotonergic alterations may play a role in the pathophysiology of paraphilias. The aims of the present study were to examine: 1) baseline plasma cortisol, plasma prolactin, and body temperature; and 2) cortisol, prolactin, body temperature, as well as behavioral responses to meta-chlorophenylpiperazine (mCPP) and placebo in pedophiles and normal men. Pedophiles showed significantly lower baseline plasma cortisol and prolactin concentrations and a higher body temperature than normal volunteers. The mCPP-induced cortisol responses were significantly greater in pedophiles than in normal volunteers. In normal volunteers, mCPP-induced a hyperthermic response, whereas in pedophiles no such response was observed. mCPP induced different behavioral responses in pedophiles than in normal men. In pedophiles, but not in normal men, mCPP increased the sensations "feeling dizzy, " "restless," and "strange" and decreased the sensation "feeling hungry". The results suggest that there are several serotonergic disturbances in pedophiles. It is hypothesized that the results are compatible with a decreased activity of the serotonergic presynaptic neuron and a 5-HT2 postsynaptic receptor hyperresponsivity.
Lee, JoonHo; Romero, Roberto; Dong, Zhong; Lee, Deug-Chan; Dong, Yi; Mittal, Pooja; Chaiworapongsa, Tinnakorn; Hassan, Sonia S.; Kim, Chong Jai
2012-01-01
Glycogen phosphorylase is a key enzyme in glycogenolysis. Released with myocardial ischemia, blood concentration of glycogen phosphorylase isoenzyme BB (GPBB) is a marker of acute coronary syndromes. Pregnancy imposes metabolic stress, and preeclampsia is associated with cardiac complications. However, plasma GPBB concentration during pregnancy is unknown. This study was conducted to determine maternal plasma GPBB concentration in normal pregnancy and in preeclampsia. Plasma samples from six groups (n=396) were studied: non-pregnant women and pregnant women with normal term delivery, term preeclampsia, term small-for-gestational-age neonates, preterm preeclampsia, and preterm small-for-gestational-age neonates. GPBB concentration was measured with a specific immunoassay. Placental tissues (n=45) obtained from pregnant women with preterm and term preeclampsia, spontaneous preterm delivery, and normal term cases were analyzed for potential GPBB expression by immunoblotting. Median plasma GPBB concentration was higher in pregnant women than in non-pregnant women (38.7 ng/ml versus 9.2 ng/mL, P<0.001), which remained significant after adjusting for age, race, and parity. Maternal plasma GPBB concentrations did not change throughout gestation. Preterm but not term preeclampsia cases had higher median plasma GPBB concentration than gestational-age-matched normal pregnancy cases (72.6 ng/ml versus 26.0 ng/ml, P=0.001). Small-for-gestational-age neonates did not affect plasma GPBB concentration. GPBB was detected in the placenta and was less abundant in preterm preeclampsia than in preterm delivery cases (P<0.01). There is physiologic elevation of plasma GPBB concentration during pregnancy; an increase in maternal plasma GPBB is a novel phenotype of preterm preeclampsia. It is strongly suggested that these changes are attributed to GPBB of placental origin. PMID:22215716
Yamada, K; Tamura, Y; Yoshida, S
1989-08-01
We examined the effect of CRH administration on the response of plasma arginine vasopressin (AVP) induced by an osmotic stimulus in six normal subjects and five patients with hypocorticotropinism without overt diabetes insipidus (four patients with Sheehan's syndrome and one with idiopathic pituitary dwarfism with ACTH deficiency). Hypertonic saline infusion (855 mmol/L saline solutions at a rate of 205 mumol/kg.min for 10 min) increased plasma AVP 5.7-fold (P less than 0.01) in normal subjects and 2.4-fold (P less than 0.05) in the patients. CRH administration significantly augmented the plasma AVP response to the osmotic stimulus in the normal subjects, but not in the patients with hypocorticotropinism. CRH administration alone did not influence plasma AVP. These findings suggest that a central CRH-related mechanism(s) was at least partly involved in the augmentation of AVP release. Based on the relatively low plasma AVP response to the osmotic stimulus in patients and their lower plasma AVP levels and higher plasma osmolality under basal conditions, we suggest that patients with hypocorticotropinism have partial diabetes insipidus, in which impairment of central CRH action might be, at least in part, involved. The response of plasma AVP to the osmotic stimulus was attenuated significantly when the patients were given cortisol. Since basal PRA, plasma aldosterone, plasma osmolality, hematocrit, body weight, mean blood pressure, and heart rate were similar with and without cortisol administration, this effect of cortisol may have been due to central suppression of the AVP response to the osmotic stimulus.
RF generator interlock by plasma grid bias current - An alternate to Hα interlock
NASA Astrophysics Data System (ADS)
Bandyopadhyay, M.; Gahlaut, A.; Yadav, R. K.; Pandya, K.; Tyagi, H.; Vupugalla, M.; Bhuyan, M.; Bhagora, J.; Chakraborty, A.
2017-08-01
ROBIN is inductively coupled plasma (ICP) based negative hydrogen ion source, operated with a 100kW, 1MHz Tetrode based RF generator (RFG). Inductive plasma ignition by the RFG in ROBIN is associated with electron seeding by a hot filament and a gas puff. RFG is triggered by the control system to deliver power just at the peak pressure of the gas puff. Once plasma is ignited due to proper impedance matching, a bright light, dominated by Hα (˜656nm wavelength) radiation is available inside RF driver which is used as a feedback signal to the RFG to continue its operation. If impedance matching is not correct, plasma is not produced due to lack of power coupling and bright light is not available. During such condition, reflected RF power may damage the RFG. Therefore, to protect the RFG, it needs to be switched off automatically within 200ms by the control system in such cases. This plasma light based RFG interlock is adopted from BATMAN ion source. However, in case of vacuum immersed RF ion source in reactor grade NBI system, such plasma light based interlock may not be feasible due to lack of adequate optical fiber interfaces. In reactor grade NBI system, neutron and gamma radiations have impact on materials which may lead to frequent maintenance and machine down time. The present demonstration of RFG interlock by Bias Current (BC) in ROBIN testbed gives an alternate option in this regard. In ROBIN, a bias plate (BP) is placed in the plasma chamber near the plasma grid (PG). BP is electrically connected to the plasma chamber wall of the ion source and PG is isolated from the wall. A high current ˜85 A direct current (DC) power supply of voltage in the range of 0 - 33V is connected between the PG and the BP in such a way that PG can be biased positively with respect to the BP or plasma chamber. This arrangement is actually made to absorb electrons and correspondingly reduce co-extracted electron current during beam extraction. However, in case of normal plasma operation, BC rises due to the presence of plasma electrons, almost in the same timescale as plasma light detection system and so, BC signal can also be used as RFG interlock. The BC signal transmission is through optical isolation to reduce noise interference with the signal. The response of the current monitoring signal available from the PG power supply of ROBIN is quite slow (in the order of few tens of milliseconds). Therefore, a fast response current detection electronic circuit having the ability to generate a PG current detection pulse with adjustable threshold set point has been developed and integrated with ROBIN, and the above concept has been demonstrated in ROBIN recently. The present paper will discuss this experimental activity and its results.
NASA Astrophysics Data System (ADS)
Mishra, Rinku; Dey, M.
2018-04-01
An analytical model is developed that explains the propagation of a high frequency electrostatic surface wave along the interface of a plasma system where semi-infinite electron-ion plasma is interfaced with semi-infinite dusty plasma. The model emphasizes that the source of such high frequency waves is inherent in the presence of ion acoustic and dust ion acoustic/dust acoustic volume waves in electron-ion plasma and dusty plasma region. Wave dispersion relation is obtained for two distinct cases and the role of plasma parameters on wave dispersion is analyzed in short and long wavelength limits. The normalized surface wave frequency is seen to grow linearly for lower wave number but becomes constant for higher wave numbers in both the cases. It is observed that the normalized frequency depends on ion plasma frequencies when dust oscillation frequency is neglected.
Connors, Susan L; Matteson, Karla J; Sega, Gary A; Lozzio, Carmen B; Carroll, Roger C; Zimmerman, Andrew W
2006-09-01
Serotonin is necessary for normal fetal brain development. Administration of serotonin inhibitors to pregnant rats results in offspring with abnormal behaviors, brain morphology, and serotonin receptor numbers. Low maternal plasma serotonin may contribute to abnormal brain development in autism. In this study, plasma serotonin levels in autism mothers and control mothers of typically developing children were compared, and plasma serotonin levels in children with autism (n = 17) and their family members were measured. Plasma serotonin levels in autism mothers were significantly lower than in mothers of normal children (P = 0.002). Plasma serotonin levels correlated between autism mothers and their children, but differed between autistic children and their fathers (P = 0.028) and siblings (P = 0.063). Low maternal plasma serotonin may be a risk factor for autism through effects on fetal brain development.
Life-threatening bleeding in a case of autoantibody-induced factor VII deficiency.
Okajima, K; Ishii, M
1999-02-01
A male patient presented with life-threatening bleeding induced by autoantibody-induced factor VII (F.VII) deficiency. This patient had macroscopic hematuria, skin ecchymosis, gastrointestinal bleeding, and a neck hematoma that was causing disturbed respiration. He developed acute renal failure and acute hepatic failure, probably due to obstruction of the ureters and the biliary tract, respectively. Although activated partial thromboplastin time was normal, prothrombin time (PT) was remarkably prolonged at 71.8 seconds compared to 14.0 seconds in a normal control. Both the immunoreactive level of F.VII antigen and the F.VII activity of the patient's plasma samples were < 1.0% of normal. Although an equal part of normal plasma was added to the patient's plasma, PT was not corrected. The patient's plasma inhibited F.VII activity. These findings suggested the presence of a plasma inhibitor for F.VII. After administration of large doses of methylprednisolone, PT was gradually shortened and plasma levels of F.VII increased over time. Bleeding, acute renal failure, and acute hepatic failure improved markedly following the steroid treatment. These observations suggest that life-threatening bleeding can be induced by autoantibody-induced F.VII deficiency and that immunosuppressive therapy using large doses of steroid can be successful in inhibiting the production of the autoantibody.
Raizes, Meytal; Elkana, Odelia; Franko, Motty; Ravona Springer, Ramit; Segev, Shlomo; Beeri, Michal Schnaider
2016-01-01
We explored the association of plasma glucose levels within the normal range with processing speed in high functioning young elderly, free of type 2 diabetes mellitus (T2DM). A sample of 41 participants (mean age = 64.7, SD = 10; glucose 94.5 mg/dL, SD = 9.3), were examined with a computerized cognitive battery. Hierarchical linear regression analysis showed that higher plasma glucose levels, albeit within the normal range (<110 mg/dL), were associated with longer reaction times (p < 0.01). These findings suggest that even in the subclinical range and in the absence of T2DM, monitoring plasma glucose levels may have an impact on cognitive function.
Development of lithium and tungsten limiters for test on T-10 tokamak at high heat load condition
NASA Astrophysics Data System (ADS)
Lyublinski, I. E.; Vertkov, A. V.; Zharkov, M. Yu; Vershkov, V. A.; Mirnov, S. V.
2016-04-01
Application of a complex of powerful (up to 3 MW) ECR plasma heating in T-10 tokamak is pulled down with a problem of the strong plasma pollution at power input more than 2 MW. For the solution of these problems the new W and Li limiters is developed and prepared to implementation. As it is supposed, application of W as a plasma facing material will allow excluding carbon influx into vacuum chamber. An additional Li limiter arranged in a shadow of W one will be used as a Li source for plasma periphery cooling due to a reradiation on Li that will lead to decrease in power deposition on W limiters. Parameters and design of limiters are presented. Plasma facing surface of a limiter is made of capillary-porous system (CPS) with Li. Porous matrix of CPS (W felt) provides stability of liquid Li surface under MHD force effect and an opportunity of its constant renewal due to capillary forces. The necessary Li flux from a Li limiter surface is estimated for maintenance of normal operation mode of W limiters at ECRH power of 3 MW during 400 ms. It is shown, that upgrade of limiters in tokamak T-10 will allow providing of ECR plasma heating with power up to 3 MW at reasonable Li flux.
In situ measurement of gas composition changes in radio frequency plasmas using a quartz sensor
DOE Office of Scientific and Technical Information (OSTI.GOV)
Suzuki, Atsushi; Nonaka, Hidehiko
2009-09-15
A simple method using a quartz sensor (Q-sensor) was developed to observe gas composition changes in radio frequency (rf) plasmas. The output depends on the gases' absolute pressure, molecular weight, and viscosity. The pressure-normalized quartz sensor output depends only on the molecular weight and viscosity of the gas. Consequently, gas composition changes can be detected in the plasmas if a sensor can be used in the plasmas. Influences imparted by the plasmas on the sensor, such as those by reactive particles (e.g., radicals and ions), excited species, electrons, temperature, and electric potentials during measurements were investigated to test the applicabilitymore » of this quartz sensor measurement to plasma. The Q-sensor measurement results for rf plasmas with argon, hydrogen, and their mixtures are reproducible, demonstrating that the Q-sensor measurement is applicable for plasmas. In this work, pressure- and temperature-normalized Q-sensor output (NQO) were used to obtain the gas composition information of plasma. Temperature-normalization of the Q-sensor output enabled quartz sensor measurements near plasma electrodes, where the quartz sensor temperature increases. The changes in NQO agreed with results obtained by gas analysis using a quadrupole mass spectrometer. Results confirmed that the change in NQO is mainly attributable to changes in the densities and kinds of gas molecules in the plasma gas phase, not by other extrinsic influences of plasma. For argon, hydrogen, and argon-hydrogen plasmas, these changes correspond to reduction in nitrogen, production of carbon monoxide, and dissociation of hydrogen molecules, respectively. These changes in NQO qualitatively and somewhat quantitatively agreed with results obtained using gas analysis, indicting that the measurement has a potential application to obtain the gas composition in plasmas without disturbing industrial plasma processes.« less
Separation of the Magnetic Field into Parts Produced by Internal and External Sources
NASA Astrophysics Data System (ADS)
Lazanja, David
2005-10-01
Given the total magnetic field on a toroidal plasma surface, a method for decomposing the field into a part due to internal currents (often the plasma) and a part due to external currents is presented. The decomposition exploits Laplace theory which is valid in the vacuum region between the plasma surface and the chamber walls. The method does not assume toroidal symmetry, and it is partly based on Merkel's 1986 work on vacuum field computations. A change in the plasma shape is produced by the total normal field perturbation on the plasma surface. This method allows a separation of the total normal field perturbation into a part produced by external currents and a part produced by the plasma response.
Madsen, Daniel Elenius; Nichols, Timothy C.; Merricks, Elizabeth P.; Waters, Emily K.; Wiinberg, Bo
2017-01-01
Introduction Canine models of severe haemophilia resemble their human equivalents both regarding clinical bleeding phenotype and response to treatment. Therefore pre-clinical studies in haemophilia dogs have allowed researchers to make valuable translational predictions regarding the potency and efficacy of new anti-haemophilia drugs (AHDs) in humans. To refine in vivo experiments and reduce number of animals, such translational studies are ideally preceded by in vitro prediction of compound efficacy using a plasma based global coagulation method. One such widely used method is the thrombin generation test (TGT). Unfortunately, commercially available TGTs are incapable of distinguishing between normal and haemophilia canine plasma, and therefore in vitro prediction using TGT has so far not been possible in canine plasma material. Aim Establish a modified TGT capable of: 1) distinguishing between normal and haemophilia canine plasma, 2) monitoring correlation between canine plasma levels of coagulation factor VIII (FVIII) and IX (FIX) and thrombin generation, 3) assessing for agreement between compound activity and thrombin generation in ex vivo samples. Methods A modified TGT assay was established where coagulation was triggered using a commercially available activated partial thromboplastin time reagent. Results With the modified TGT a significant difference was observed in thrombin generation between normal and haemophilia canine plasma. A dose dependent thrombin generation was observed when assessing haemophilia A and B plasma spiked with dilution series of FVIII and FIX, respectively. Correlation between FVIII activity and thrombin generation was observed when analyzing samples from haemophilia A dogs dosed with canine FVIII. Limit of detection was 0.1% (v/v) FVIII or FIX. Conclusion A novel modified TGT suitable for monitoring and prediction of replacement therapy efficacy in plasma from haemophilia A and B dogs was established. PMID:28384182
Konishi, H; Ichikawa, D; Komatsu, S; Shiozaki, A; Tsujiura, M; Takeshita, H; Morimura, R; Nagata, H; Arita, T; Kawaguchi, T; Hirashima, S; Fujiwara, H; Okamoto, K; Otsuji, E
2012-01-01
Background: Recently, it was reported that plasma microRNAs (miRNAs) are low-invasive useful biomarkers for cancer. We attempted to isolate gastric cancer (GC)-associated miRNAs comparing pre- and post-operative paired plasma, thereby excluding the possible effects of individual variability. Methods: This study was divided into four steps: (1) microarray analysis comparing pre- and post-operative plasma; (2) validation of candidate miRNAs by quantitative RT–PCR; (3) validation study of selected miRNAs using paired plasma; and (4) comparison of the levels of selected miRNAs in plasma between healthy controls and patients. Results: From the results of microarray analysis, nine candidate miRNAs the levels of which were markedly decreased in post-operative plasma were selected for further studies. After confirmation of their post-operative marked reduction, two candidate miRNAs, miR-451 and miR-486, were selected as plasma biomarkers, considering the abundance in plasma, and marked decrease in post-operative samples. In validation, the two miRNAs were found to decrease in post-operative plasma in 90 and 93% of patients (both P<0.01). In comparison with healthy controls, the levels of both miRNAs were found to be significantly higher in patients, and the area under the curve values were high at 0.96 and 0.92. Conclusion: Plasma miR-451 and miR-486 could be useful blood-based biomarkers for screening GC. PMID:22262318
Control of impurities in toroidal plasma devices
Ohkawa, Tihiro
1980-01-01
A method and apparatus for plasma impurity control in closed flux plasma systems such as Tokamak reactors is disclosed. Local axisymmetrical injection of hydrogen gas is employed to reverse the normally inward flow of impurities into the plasma.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brennan, D. P.; Finn, J. M.
2014-10-15
Feedback stabilization of magnetohydrodynamic (MHD) modes in a tokamak is studied in a cylindrical model with a resistive wall, plasma resistivity, viscosity, and toroidal rotation. The control is based on a linear combination of the normal and tangential components of the magnetic field just inside the resistive wall. The feedback includes complex gain, for both the normal and for the tangential components, and it is known that the imaginary part of the feedback for the former is equivalent to plasma rotation [J. M. Finn and L. Chacon, Phys. Plasmas 11, 1866 (2004)]. The work includes (1) analysis with a reducedmore » resistive MHD model for a tokamak with finite β and with stepfunction current density and pressure profiles, and (2) computations with a full compressible visco-resistive MHD model with smooth decreasing profiles of current density and pressure. The equilibria are stable for β = 0 and the marginal stability values β{sub rp,rw} < β{sub rp,iw} < β{sub ip,rw} < β{sub ip,iw} (resistive plasma, resistive wall; resistive plasma, ideal wall; ideal plasma, resistive wall; and ideal plasma, ideal wall) are computed for both models. The main results are: (a) imaginary gain with normal sensors or plasma rotation stabilizes below β{sub rp,iw} because rotation suppresses the diffusion of flux from the plasma out through the wall and, more surprisingly, (b) rotation or imaginary gain with normal sensors destabilizes above β{sub rp,iw} because it prevents the feedback flux from entering the plasma through the resistive wall to form a virtual wall. A method of using complex gain G{sub i} to optimize in the presence of rotation in this regime with β > β{sub rp,iw} is presented. The effect of imaginary gain with tangential sensors is more complicated but essentially destabilizes above and below β{sub rp,iw}.« less
Ohba, Seigo; Sumita, Yoshinori; Umebayashi, Mayumi; Yoshimura, Hitoshi; Yoshida, Hisato; Matsuda, Shinpei; Kimura, Hideki; Asahina, Izumi; Sano, Kazuo
2016-01-01
The aim of this study was to assess newly formed onlay bone on mouse calvarial bone using a new artificial bone material, a hydroxyapatite/collagen composite, with total blood or platelet-rich plasma. The hydroxyapatite/collagen composite material with normal saline, total blood or platelet-rich plasma was transplanted on mouse calvarial bone. The mice were sacrificed and the specimens were harvested four weeks after surgery. The newly formed bone area was measured on hematoxylin and eosin stained specimens using Image J software. The hydroxyapatite/collagen composite materials with total blood or platelet-rich plasma induced a significantly greater amount of newly formed bone than that with normal saline. Moreover, bone marrow was observed four weeks after surgery in the transplanted materials with total blood or platelet-rich plasma but not with normal saline. However, there were no significant differences in the amount of newly formed bone between materials used with total blood versus platelet-rich plasma. The hydroxyapatite/collagen composite material was valid for onlay bone augmentation and this material should be soaked in total blood or platelet-rich plasma prior to transplantation. Copyright © 2015 Elsevier Ltd. All rights reserved.
Plasma Shh levels reduced in pancreatic cancer patients
El-Zaatari, Mohamad; Daignault, Stephanie; Tessier, Art; Kelsey, Gail; Travnikar, Lisa A.; Cantu, Esperanza F.; Lee, Jamie; Plonka, Caitlyn M.; Simeone, Diane M.; Anderson, Michelle A.; Merchant, Juanita L.
2012-01-01
Objectives Normally, sonic hedgehog (Shh) is expressed in the pancreas during fetal development and transiently after tissue injury. Although pancreatic cancers express Shh, it is not known if the protein is secreted into the blood and whether its plasma levels change with pancreatic transformation. The goal of this study was to develop an ELISA to detect human Shh in blood, and determine the levels in subjects with and without pancreatic cancer. Methods A human Shh ELISA assay was developed, and plasma Shh levels were measured in blood samples from normal volunteers and subjects with pancreatitis or pancreatic cancer. The biological activity of plasma Shh was tested using NIH-3T3 cells. Results The average levels of Shh in human blood were lower in pancreatitis and pancreatic cancer patients than in normal individuals. Hematopoietic cells did not express Shh suggesting that Shh is secreted into the bloodstream. Plasma fractions enriched for Shh did not induce Gli-1 mRNA suggesting that the protein was not biologically active. Conclusions Shh is secreted from tissues and organs into the circulation but its activity is blocked by plasma proteins. Reduced plasma levels were found in pancreatic cancer patients, but alone were not sufficient to predict pancreatic cancer. PMID:22513293
Time-delayed transition of normal-to-abnormal glow in pin-to-water discharge
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yoon, S.-Y.; Byeon, Y.-S.; Yoo, S.
2016-08-15
Time-delayed transition of normal-to-abnormal glow was investigated in discharge between spoke-like pins and ultrapure water by applying AC-driven power at a frequency of 14.3 kHz at atmospheric pressure. The normal-to-abnormal transition can be recognized from the slope changes of current density, gas temperature, electrode temperature, and OH density. The slope changes took place in tens of minutes rather than just after discharge, in other words, the transition was delayed. The time-delay of the transition was caused by the interaction between the plasma and water. The plasma affected water properties, and then the water affected plasma properties.
Berruyer, M; Amiral, J; Ffrench, P; Belleville, J; Bastien, O; Clerc, J; Kassir, A; Estanove, S; Dechavanne, M
1993-05-01
Brief case histories of three patients aged 58, 38, and 44 years are reported. All underwent cardiovascular operations. Subsequently hemostasis test abnormalities developed between the seventh and eighth postoperative days after exposure to bovine thrombin used with fibrin glue. These were characterized by an increased activated partial thromboplastin time (64 to 147 seconds), prothrombin time (19 to 24 seconds), bovine thrombin time (> 120 seconds) and a markedly reduced factor V level (< 10% in two patients and 16% in the third patient). A patient plasma dilution of 1 in 200 with a normal plasma pool was necessary to correct bovine thrombin time. No fast-acting or progressive inhibitor against factor V could be detected by coagulation tests, and fresh frozen plasma perfusion had no effect. Plasmapheresis was performed preventatively to avoid bleeding, and factor V levels stabilized at around 50% after two to four exchanges. Immunologic studies showed that the inhibitors were directed not only against bovine factors but also against human ones. Therefore factor V decrease could have been the result of rapid clearance from the circulation of complexes formed with a nonneutralizing inhibitor that is not detected by clotting tests. These antibodies were purified by standard methods and immunoaffinity. Fast immunization could be explained by a prior sensitization to bovine thrombin exposure during previous operations. It is suggested that bovine thrombin used with fibrin glue contains small amounts of factor V and may be responsible for these abnormalities. This is in agreement with previous literature reports. However, these described neutralizing factor V inhibitors, which were easily detected.
Effects of Platelet-Rich Plasma and Indomethacin on Biomechanics of Rotator Cuff Repair.
Meadows, Molly C; Levy, David M; Ferry, Christopher M; Gardner, Thomas R; Teratani, Takeshi; Ahmad, Christopher S
We conducted a study to determine if platelet-rich plasma (PRP) enhances the strength of rotator cuff repair (RCR) and if concomitant use of nonsteroidal anti-inflammatory drugs (NSAIDs) affects PRP efficacy. We also wanted to determine the optimal centrifugation protocol for making PRP from rats. This study used 48 rats, 14 in a centrifugation protocol and 34 in an operative protocol. Six syngeneic rats from the operative group were used as PRP blood donors; the other 28 operative rats underwent bilateral RCRs. The Autologous Conditioned Plasma system (Arthrex) was used to prepare leukocyte-poor PRP. One shoulder was randomized to an intratendinous PRP injection, and the other received normal saline. Each rat was also randomly placed on a postoperative diet, either a regular diet or an indomethacin-enhanced diet. After rats were euthanized at 3 weeks, specimens were dissected to isolate the supraspinatus tendon at its humeral attachment, which was subjected to biomechanical testing. PRP prepared with a protocol of 5 minutes × 1300 revolutions per minute had the highest platelet index. Mean (SD) energy to failure was significantly higher (P = .03) in tendons treated with PRP, 11.7 (7.3) N-mm, than in tendons treated with saline, 8.7 (4.6) N-mm. Both groups (PRP, saline) showed no significant differences between tendons treated with NSAIDs and those not treated with NSAIDs. Intraoperative application of PRP enhances energy to failure after RCR in rats. There were no differences in biomechanical strength with NSAID use and no interactions between PRP and NSAID use.
Boonla, Orachorn; Kukongviriyapan, Upa; Pakdeechote, Poungrat; Kukongviriyapan, Veerapol; Pannangpetch, Patchareewan; Thawornchinsombut, Supawan
2015-01-01
In recent years, a number of studies have investigated complementary medical approaches to the treatment of hypertension using dietary supplements. Rice bran protein hydrolysates extracted from rice is a rich source of bioactive peptides. The present study aimed to investigate the vasorelaxation and antihypertensive effects of peptides-derived from rice bran protein hydrolysates (RBP) in a rat model of two kidney-one clip (2K-1C) renovascular hypertension. 2K-1C hypertension was induced in male Sprague-Dawley rats by placing a silver clip around the left renal artery, whereas sham-operated rats were served as controls. 2K-1C and sham-operated rats were intragastrically administered with RBP (50 mg·kg−1 or 100 mg·kg−1) or distilled water continuously for six weeks. We observed that RBP augmented endothelium-dependent vasorelaxation in all animals. Administration of RBP to 2K-1C rats significantly reduced blood pressure and decreased peripheral vascular resistance compared to the sham operated controls (p < 0.05). Restoration of normal endothelial function and blood pressure was associated with reduced plasma angiotensin converting enzyme (ACE), decreased superoxide formation, reduced plasma malondialdehyde and increased plasma nitrate/nitrite (p < 0.05). Up-regulation of eNOS protein and down-regulation of p47phox protein were found in 2K-1C hypertensive rats-treated with RBP. Our results suggest that RBP possesses antihypertensive properties which are mainly due to the inhibition of ACE, and its vasodilatory and antioxidant activity. PMID:26184305
Winston, Charisse N; Goetzl, Edward J; Akers, Johnny C; Carter, Bob S; Rockenstein, Edward M; Galasko, Douglas; Masliah, Eliezer; Rissman, Robert A
2016-01-01
Levels of Alzheimer's disease (AD)-related proteins in plasma neuronal derived exosomes (NDEs) were quantified to identify biomarkers for prediction and staging of mild cognitive impairment (MCI) and AD. Plasma exosomes were extracted, precipitated, and enriched for neuronal source by anti-L1CAM antibody absorption. NDEs were characterized by size (Nanosight) and shape (TEM) and extracted NDE protein biomarkers were quantified by ELISAs. Plasma NDE cargo was injected into normal mice, and results were characterized by immunohistochemistry to determine pathogenic potential. Plasma NDE levels of P-T181-tau, P-S396-tau, and Aβ1-42 were significantly higher, whereas those of neurogranin (NRGN) and the repressor element 1-silencing transcription factor (REST) were significantly lower in AD and MCI converting to AD (ADC) patients compared to cognitively normal controls (CNC) subjects and stable MCI patients. Mice injected with plasma NDEs from ADC patients displayed increased P-tau (PHF-1 antibody)-positive cells in the CA1 region of the hippocampus compared to plasma NDEs from CNC and stable MCI patients. Abnormal plasma NDE levels of P-tau, Aβ1-42, NRGN, and REST accurately predict conversion of MCI to AD dementia. Plasma NDEs from demented patients seeded tau aggregation and induced AD-like neuropathology in normal mouse CNS.
Tang, Lanhua; Xia, Zhuying; Luo, Zhongwei; Long, Haitao; Zhu, Yong; Zhao, Shushan
2017-08-01
Objective This study aimed to investigate the association between low plasma Platelet-derived growth factor-BB (PDGF-BB) levels and oestradiol in Postmenopausal osteoporosis (PMOP). Methods This prospective study measured plasma PDGF-BB and oestradiol levels in outpatients who were admitted to our hospital. Participants were screened and then allocated to three groups: normal young women, postmenopausal control, and PMOP. Additionally, Sprague-Dawley rats underwent either sham surgery or bilateral ovariectomy (OVX), and were divided into the following groups: sham, OVX, OVX + oestradiol, and OVX + PDGF-BB. Plasma oestradiol and PDGF-BB levels were measured using commercially available ELISA kits. Results A total of 121 participants, including 69 normal young women, 28 patients with primary PMOP, and 24 age-matched postmenopausal women were enrolled. Plasma oestradiol and PDGF-BB levels were lower in postmenopausal women, especially in PMOP ( P < 0.01). Pearson correlations analysis showed that PDGF-BB levels were positively correlated with oestradiol levels and inversely correlated with age ( P < 0.01). The OVX rat model showed that oestradiol replacement increased plasma PDGF-BB levels, while PDGF-BB systematic treatment had no effect on plasma oestradiol levels. Conclusions Plasma PDGF-BB levels are maintained by oestrogen in normal young women and play a major role in PMOP.
A mechanism for magnetospheric substorms
NASA Technical Reports Server (NTRS)
Erickson, G. M.; Heinemann, M.
1994-01-01
Energy-principle analysis performed on two-dimensional, self-consistent solutions for magnetospheric convection indicates that the magnetosphere is unstable to isobaric (yet still frozen-in) fluctuations of plasma-sheet flux tubes. Normally, pdV work associated with compression maintains stability of the inward/outward oscillating normal mode. However, if Earth's ionosphere can provide sufficient mass flux, isobaric expansion of flux tubes can occur. The growth of a field-aligned potential drop in the near-Earth, midnight portion of the plasma sheet, associated with upward field-aligned currents responsible for the Harang discontinuity, redistributes plasma along field lines in a manner that destabilizes the normal mode. The growth of this unstable mode results in an out-of-equilibrium situation near the inner edge. When this occurs over a downtail extent comparable to the half-thickness of the plasma sheet, collapse ensues and forces thinning of the plasma sheet whereby conditions favorable to reconnection occur. This scenario for substorm onset is consistent with observed upward fluxes of ions, parallel potential drops, and observations of substorm onset. These observations include near Earth onset, pseudobreakups, the substorm current wedge, and local variations of plasma-sheet thickness.
Suppressing magnetic island growth by resonant magnetic perturbation
NASA Astrophysics Data System (ADS)
Yu, Q.; Günter, S.; Lackner, K.
2018-05-01
The effect of externally applied resonant magnetic perturbations (RMPs) on the growth of magnetic islands is investigated based on two-fluid equations. It is found that if the local bi-normal electron fluid velocity at the resonant surface is sufficiently large, static RMPs of the same helicity and of moderate amplitude can suppress the growth of magnetic islands in high-temperature plasmas. These islands will otherwise grow, driven by an unfavorable plasma current density profile and bootstrap current perturbation. These results indicate that the error field can stabilize island growth, if the error field amplitude is not too large and the local bi-normal electron fluid velocity is not too low. They also indicate that applied rotating RMPs with an appropriate frequency can be utilized to suppress island growth in high-temperature plasmas, even for a low bi-normal electron fluid velocity. A significant change in the local equilibrium plasma current density gradient by small amplitude RMPs is found for realistic plasma parameters, which are important for the island stability and are expected to be more important for fusion reactors with low plasma resistivity.
Vibrational Modes of Oblate Clouds of Charge
NASA Astrophysics Data System (ADS)
Jenkins, Thomas; Spencer, Ross L.
2000-10-01
When a nonneutral plasma confined in a Penning trap is allowed time to expand, its shape at global thermal equilibrium is that of a thin oblate spheroid [D. L. Paulson et al., Phys. Plasmas 5, 345 (1998)]. Oscillations similar to those of a drumhead can be externally induced in such a plasma. Although a theory developed by Dubin predicts the frequencies of the various normal modes of oscillation [Phys. Rev. Lett. 66, 2076 (1991)], this theory assumes that the plasma has zero temperature and is confined by an ideal quadrupole electric field. Neither of these conditions is strictly true in experiments [C. S. Weimer et al., Phys. Rev. A 49, 3842 (1994)] where physical properties of the plasma are deduced from measurements of these frequencies, causing the measurements and ideal theory to differ by about 20%. We reformulate the problem of the normal oscillatory modes as a principal-value integral eigenvalue equation, including finite-temperature and non-ideal confinement effects. The equation is solved numerically to obtain the plasma's normal mode frequencies and shapes; reasonable agreement with experiment is obtained.
Spontaneous endocrine cure of gigantism due to pituitary apoplexy.
Arisaka, O; Hall, R; Hughes, I A
1983-10-08
An 11 year old, tall boy presented with symptoms typical of pituitary apoplexy. A large necrotic and haemorrhagic tumour was removed, which was shown to be an adenoma secreting growth hormone and prolactin. Subsequent treatment comprised cranial irradiation and hormone replacement. Eighteen months after operation growth was static and plasma growth hormone and prolactin concentrations were undetectable. Treatment of pituitary apoplexy should comprise excision of the tumour and postoperative irradiation; such treatment after early recognition of the condition offers the best chance of preserving normal pituitary function in children with gigantism.
Spontaneous endocrine cure of gigantism due to pituitary apoplexy.
Arisaka, O; Hall, R; Hughes, I A
1983-01-01
An 11 year old, tall boy presented with symptoms typical of pituitary apoplexy. A large necrotic and haemorrhagic tumour was removed, which was shown to be an adenoma secreting growth hormone and prolactin. Subsequent treatment comprised cranial irradiation and hormone replacement. Eighteen months after operation growth was static and plasma growth hormone and prolactin concentrations were undetectable. Treatment of pituitary apoplexy should comprise excision of the tumour and postoperative irradiation; such treatment after early recognition of the condition offers the best chance of preserving normal pituitary function in children with gigantism. PMID:6311318
MiOXSYS: a novel method of measuring oxidation reduction potential in semen and seminal plasma.
Agarwal, Ashok; Sharma, Rakesh; Roychoudhury, Shubhadeep; Du Plessis, Stefan; Sabanegh, Edmund
2016-09-01
To measure oxidative reduction potential (ORP) in semen and seminal plasma and to establish their reference levels. ORP levels were measured in semen and seminal plasma. Tertiary hospital. Twenty-six controls and 33 infertile men. None. Static ORP (sORP) and capacitance ORP (cORP) were measured in semen and seminal plasma at time 0 and 120 minutes. Correlation of ORP was assessed between [1] semen and seminal plasma and [2] time 0 and 120 minutes. The association with sperm parameters was studied in (a) controls and (b) infertile patients, and a receiver operating characteristic curve was generated to establish the sORP cutoff. Semen sORP and cORP levels were associated with seminal plasma levels at time 0 and time 120 minutes. In controls and infertile patients, an inverse relationship of sORP levels was established with concentration and total sperm count in semen as well as seminal plasma at time 0 and 120 minutes. Classification of subjects based on sperm motility showed that subjects with abnormal motility present with poor concentration, total count, morphology, and elevated levels of semen and seminal plasma sORP at time 120 minutes. The sORP cutoff of 1.48 in semen and 2.09 in seminal plasma based on motility was able to distinguish subjects with normal semen quality from those with abnormal semen quality. The MiOXSYS System can reliably measure ORP levels in semen and seminal plasma. ORP levels are not affected by semen age, making this new technology easy to employ in a clinical setting. Copyright © 2016 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.
Rice, Nicklaus T.; Szlam, Fania; Varner, Jeffrey D.; Bernstein, Peter S.; Szlam, Arthur D.; Tanaka, Kenichi A.
2016-01-01
Background Thrombin generation (TG) is a pivotal process in achieving hemostasis. Coagulation profiles during pregnancy and early neonatal period are different from that of normal (non-pregnant) adults. In this ex vivo study, the differences in TG in maternal and cord plasma relative to normal adult plasma were studied. Methods Twenty consented pregnant women and ten consented healthy adults were included in the study. Maternal and cord blood samples were collected at the time of delivery. Platelet-poor plasma was isolated for the measurement of TG. In some samples, anti-FIXa aptamer, RB006, or a TFPI inhibitor, BAX499 were added to elucidate the contribution of intrinsic and extrinsic pathway to TG. Additionally, procoagulant and inhibitor levels were measured in maternal and cord plasma, and these values were used to mathematically simulate TG. Results Peak TG was increased in maternal plasma (393.6±57.9 nM) compared to adult and cord samples (323.2±38.9 nM and 209.9±29.5 nM, respectively). Inhibitory effects of RB006 on TG were less robust in maternal or cord plasma (52% vs. 12% respectively) than in adult plasma (81%). Likewise the effectiveness of BAX499 as represented by the increase in peak TG was much greater in adult (21%) than in maternal (10%) or cord plasma (12%). Further, BAX499 was more effective in reversing RB006 in adult plasma than in maternal or cord plasma. Ex vivo data were reproducible with the results of the mathematical simulation of TG. Conclusion Normal parturient plasma shows a large intrinsic pathway reserve for TG compared to adult and cord plasma, while TG in cord plasma is sustained by extrinsic pathway, and low levels of TFPI and AT. PMID:27196067
Surface wave and linear operating mode of a plasma antenna
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bogachev, N. N., E-mail: bgniknik@yandex.ru; Bogdankevich, I. L.; Gusein-zade, N. G.
The relation between the propagation conditions of a surface electromagnetic wave along a finiteradius plasma cylinder and the linear operating mode of a plasma antenna is investigated. The solution to the dispersion relation for a surface wave propagating along a finite-radius plasma cylinder is analyzed for weakly and strongly collisional plasmas. Computer simulations of an asymmetrical plasma dipole antenna are performed using the KARAT code, wherein the dielectric properties of plasma are described in terms of the Drude model. The plasma parameters corresponding to the linear operating mode of a plasma antenna are determined. It is demonstrated that the characteristicsmore » of the plasma antenna in this mode are close to those of an analogous metal antenna.« less
Impact of ideal MHD stability limits on high-beta hybrid operation
NASA Astrophysics Data System (ADS)
Piovesan, P.; Igochine, V.; Turco, F.; Ryan, D. A.; Cianciosa, M. R.; Liu, Y. Q.; Marrelli, L.; Terranova, D.; Wilcox, R. S.; Wingen, A.; Angioni, C.; Bock, A.; Chrystal, C.; Classen, I.; Dunne, M.; Ferraro, N. M.; Fischer, R.; Gude, A.; Holcomb, C. T.; Lebschy, A.; Luce, T. C.; Maraschek, M.; McDermott, R.; Odstrčil, T.; Paz-Soldan, C.; Reich, M.; Sertoli, M.; Suttrop, W.; Taylor, N. Z.; Weiland, M.; Willensdorfer, M.; The ASDEX Upgrade Team; The DIII-D Team; The EUROfusion MST1 Team
2017-01-01
The hybrid scenario is a candidate for stationary high-fusion gain tokamak operation in ITER and DEMO. To obtain such performance, the energy confinement and the normalized pressure {βN} must be maximized, which requires operating near or above ideal MHD no-wall limits. New experimental findings show how these limits can affect hybrid operation. Even if hybrids are mainly limited by tearing modes, proximity to the no-wall limit leads to 3D field amplification that affects plasma profiles, e.g. rotation braking is observed in ASDEX Upgrade throughout the plasma and peaks in the core. As a result, even the small ASDEX Upgrade error fields are amplified and their effects become visible. To quantify such effects, ASDEX Upgrade measured the response to 3D fields applied by 8× 2 non-axisymmetric coils as {βN} approaches the no-wall limit. The full n = 1 response profile and poloidal structure were measured by a suite of diagnostics and compared with linear MHD simulations, revealing a characteristic feature of hybrids: the n = 1 response is due to a global, marginally-stable n = 1 kink characterized by a large m = 1, n = 1 core harmonic due to q min being just above 1. A helical core distortion of a few cm forms and affects various core quantities, including plasma rotation, electron and ion temperature, and intrinsic W density. In similar experiments, DIII-D also measured the effect of this helical core on the internal current profile, providing information useful to understanding of the physics of magnetic flux pumping, i.e. anomalous current redistribution by MHD modes that keeps {{q}\\text{min}}>1 . Thanks to flux pumping, a broad current profile is maintained in DIII-D even with large on-axis current drive, enabling fully non-inductive operation at high {βN} up to 3.5-4.
Impact of ideal MHD stability limits on high-beta hybrid operation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Piovesan, Paolo; Igochine, V.; Turco, F.
Here, the hybrid scenario is a candidate for stationary high-fusion gain tokamak operation in ITER and DEMO. To obtain such performance, the energy confinement and the normalized pressuremore » $${{\\beta}_{N}}$$ must be maximized, which requires operating near or above ideal MHD no-wall limits. New experimental findings show how these limits can affect hybrid operation. Even if hybrids are mainly limited by tearing modes, proximity to the no-wall limit leads to 3D field amplification that affects plasma profiles, e.g. rotation braking is observed in ASDEX Upgrade throughout the plasma and peaks in the core. As a result, even the small ASDEX Upgrade error fields are amplified and their effects become visible. To quantify such effects, ASDEX Upgrade measured the response to 3D fields applied by $$8\\times 2$$ non-axisymmetric coils as $${{\\beta}_{N}}$$ approaches the no-wall limit. The full n = 1 response profile and poloidal structure were measured by a suite of diagnostics and compared with linear MHD simulations, revealing a characteristic feature of hybrids: the n = 1 response is due to a global, marginally-stable n = 1 kink characterized by a large m = 1, n = 1 core harmonic due to q min being just above 1. A helical core distortion of a few cm forms and affects various core quantities, including plasma rotation, electron and ion temperature, and intrinsic W density. In similar experiments, DIII-D also measured the effect of this helical core on the internal current profile, providing information useful to understanding of the physics of magnetic flux pumping, i.e. anomalous current redistribution by MHD modes that keeps $${{q}_{\\text{min}}}>1$$ . Thanks to flux pumping, a broad current profile is maintained in DIII-D even with large on-axis current drive, enabling fully non-inductive operation at high $${{\\beta}_{N}}$$ up to 3.5–4.« less
Impact of ideal MHD stability limits on high-beta hybrid operation
Piovesan, Paolo; Igochine, V.; Turco, F.; ...
2016-10-27
Here, the hybrid scenario is a candidate for stationary high-fusion gain tokamak operation in ITER and DEMO. To obtain such performance, the energy confinement and the normalized pressuremore » $${{\\beta}_{N}}$$ must be maximized, which requires operating near or above ideal MHD no-wall limits. New experimental findings show how these limits can affect hybrid operation. Even if hybrids are mainly limited by tearing modes, proximity to the no-wall limit leads to 3D field amplification that affects plasma profiles, e.g. rotation braking is observed in ASDEX Upgrade throughout the plasma and peaks in the core. As a result, even the small ASDEX Upgrade error fields are amplified and their effects become visible. To quantify such effects, ASDEX Upgrade measured the response to 3D fields applied by $$8\\times 2$$ non-axisymmetric coils as $${{\\beta}_{N}}$$ approaches the no-wall limit. The full n = 1 response profile and poloidal structure were measured by a suite of diagnostics and compared with linear MHD simulations, revealing a characteristic feature of hybrids: the n = 1 response is due to a global, marginally-stable n = 1 kink characterized by a large m = 1, n = 1 core harmonic due to q min being just above 1. A helical core distortion of a few cm forms and affects various core quantities, including plasma rotation, electron and ion temperature, and intrinsic W density. In similar experiments, DIII-D also measured the effect of this helical core on the internal current profile, providing information useful to understanding of the physics of magnetic flux pumping, i.e. anomalous current redistribution by MHD modes that keeps $${{q}_{\\text{min}}}>1$$ . Thanks to flux pumping, a broad current profile is maintained in DIII-D even with large on-axis current drive, enabling fully non-inductive operation at high $${{\\beta}_{N}}$$ up to 3.5–4.« less
Method and means for measuring the anisotropy of a plasma in a magnetic field
Shohet, J.L.; Greene, D.G.S.
1973-10-23
Anisotropy is measured of a free-free-bremsstrahlungradiation-generating plasma in a magnetic field by collimating the free-free bremsstrahlung radiation in a direction normal to the magnetic field and scattering the collimated free- free bremsstrahlung radiation to resolve the radiation into its vector components in a plane parallel to the electric field of the bremsstrahlung radiation. The scattered vector components are counted at particular energy levels in a direction parallel to the magnetic field and also normal to the magnetic field of the plasma to provide a measure of anisotropy of the plasma. (Official Gazette)
Matsubara, M; Odagaki, E; Morioka, T; Nakagawa, K
1987-05-20
The clinical significance of the measurement of plasma transferrin (Tf) in patients with hypophysial disorders was reported in our previous papers. In the present study, we determined plasma Tf levels in 55 patients with various endocrine states and considered their clinical significance compared with plasma somatomedin-C (SM-C) levels. Plasma Tf levels decreased significantly in patients with anorexia nervosa (p less than 0.02), hyperthyroidism (p less than 0.05), primary hypothyroidism (p less than 0.05) and Cushing's syndrome (p less than 0.05), while they were elevated significantly in pregnancy (p less than 0.01) or females using estrogens (p less than 0.05). The former two declines were considered a reflection of the malnutritional state of the patients since a significant negative correlation was observed between plasma Tf levels and the percentile deficit from the ideal body weight in patients with anorexia nervosa (p less than 0.01), or between plasma Tf levels and elevated T3 levels which induce hypermetabolism in patients with hyperthyroidism (p less than 0.01). A significant correlation was observed between the SM-C and Tf levels in these subjects (including normal controls and patients with hypophysial disorders) as a whole (r = 0.79, p less than 0.001). These data indicate that plasma Tf is changeable according to the endocrinological and nutritional conditions with good correlation to the SM-C, and it is suggested that Tf also operates as a growth factor in vivo.
Erez, Offer; Romero, Roberto; Vaisbuch, Edi; Than, Nandor Gabor; Kusanovic, Juan Pedro; Mazaki-Tovi, Shali; Gotsch, Francesca; Mittal, Pooja; Dong, Zhong; Chaiworapongsa, Tinnakorn; Kim, Chong Jai; Nhan-Chang, Chia-Ling; Kim, Sun Kwon; Yeo, Lami; Mazor, Moshe; Hassan, Sonia S
2018-06-01
The aim of this study was to determine whether the activity of tissue factor (TF) and tissue factor pathway inhibitor (TFPI) in the plasma of women with preeclampsia (PE) and small for gestational age (SGA) neonate differ from that of normal pregnant women and whether they are related to specific placental lesions. This cross-sectional study included the following groups: (1) normal pregnancy (n = 68); (2) PE (n= 128); and (3) SGA (n = 56). Maternal plasma TF and TFPI activity was determined with chromogenic assays. (1) The median maternal plasma TF activity, but not TFPI activity, differed among the study groups (p < .0001 and p = .4, respectively); (2) patients with PE had a higher median maternal plasma TF activity than women with normal pregnancies (p < .0001) and mothers with SGA fetuses (p = .002); (3) among patients with PE, those with distal villous hypoplasia had a higher median maternal TF activity than those without these placental lesions (p = .018); and (4) following adjustment for confounding variables, maternal plasma TF and TFPI activity were not associated with an SGA neonate. Plasma TF activity is higher in women with PE than in those with SGA or normal pregnancies. We propose that these changes may be responsible, at least in part, for the increased in-vivo thrombin generation observed in this obstetrical syndrome.
Xu, Zhi-song; Bao, Zi-yu; Wang, Zhi-ying; Yang, Guo-jun; Zhu, Dong-fang; Zhang, Li; Tan, Rong-mei
2012-07-01
To investigate the changes of plasma ghrelin, growth hormone (GH) and growth hormone releasing hormone (GHRH) and gastric ghrelin in patients with chronic obstructive pulmonary disease (COPD) and to explore their clinical significances. Plasma ghrelin, GH, GHRH, TNFα, IL-6 and C reactive protein (CRP) were measured in 40 COPD patients and 20 controls with chronic bronchitis. Correlated factors of plasma ghrelin, TNFα, IL-6, CRP were analyzed. Body composition was assessed with bioelectrical impedance analysis. The expression of gastric ghrelin in patients with COPD was detected. Plasma ghrelin was higher in the underweight patients than in the normal weight patients and in the controls [(1.78 ± 0.46) ng/L, (1.39 ± 0.46) ng/L, (1.36 ± 0.39) ng/L, respectively]. Plasma GH was lower in the underweight patients than in the normal weight patients and in the controls [(4.12 ± 0.83) µg/L, (5.17 ± 0.72)µg/L, (6.49 ± 1.13) µg/L, respectively]. Plasma GHRH was lower in the underweight patients than in the normal weight patients and in the controls [(20.43 ± 4.41) ng/L, (23.47 ± 3.97) ng/L, (27.48 ± 10.06) ng/L, respectively]. Plasma ghrelin was higher in the underweight patients than in the controls (P < 0.01). Plasma ghrelin was higher in the underweight patients than in the normal weight patients with COPD. Plasma ghrelin (log transformed) was negatively correlated with BMI and percentage of body fat in the COPD patients. Plasma GHRH was positively correlated with ghrelin in the underweight patients (r = 0.515, P < 0.05), while no correlation was found between plasma GH and ghrelin in the underweight patients (r = 0.415, P > 0.05). Plasma ghrelin was positively correlated with TNFα and IL-6 in the underweight patients. The gastric expression of ghrelin showed no evident difference between the patients with COPD and the controls. The plasma GH in COPD patients may not be correlated with ghrelin. The plasma ghrelin level may be a useful indicator for malnutrition in COPD patients. Plasma ghrelin might be involved in the pathogenesis of CODP by affecting the body energy metabolism.
Kuta, Piotr; Hauck-Dlimi, Barbara; Strobel, Julian; Zimmermann, Robert; Eckstein, Reinhold
2016-01-01
Uncontrolled hemorrhage in polytrauma patients usually results in rapid need of blood products. Despite the shorter thawing times of microwave devices for heating fresh frozen plasma (FFP), their use has remained controversial, and just a few laboratory analyses have been published on this topic. The aim of this study was to analyse the quality of clotting factors immediately after thawing FFP with a microwave device and after 48-hour post thaw storage at 4 degrees C. 24 FFP units of all four ABO blood groups (six of each blood group) were thawed with a Transfusio-therm 2000 and later stored at 4 degrees C for 48 hours. Samples were drawn aseptically and investigated on various clotting factors and protein proteases (fibrinogen, antithrombin, FII, FV, FVII, FVIII, FIX, FX, FXI, FXIII, vWF antigen and activity, protein S, and protein C) using standard coagulation and chromogenic assays immediately after thawing and again after a 48-hour storage period at 4 degrees C. All units were tested for both anaerobic and aerobic microbial contamination using standard operating procedures immediately after thawing. After thawing, all coagulation factors and protein protease activities were within normal ranges. Blood group O individuals had approximately 25% lower plasma levels of vWF antigen and activity. After a 48-hour storage period at 4 degrees C, FVIII and FIX activities declined significantly in all blood groups, whereas the remaining clotting factors remained comparably stable. Immediately after rapid thawing using a microwave system, all FFP units contained adequate coagulation factor activities to maintain hemostatic activity at the time of product thaw. The post thaw refrigerated storage caused an anticipated decrease in factor VIII and IX activities, but retained normal coagulation factor levels of many plasma proteins. Therefore we conclude that the Transfusio-therm 2000 has no clinically significant influence on the activity of clotting factors and plasma proteases in FFP units.
Conceptual Design of the ITER Plasma Control System
NASA Astrophysics Data System (ADS)
Snipes, J. A.
2013-10-01
The conceptual design of the ITER Plasma Control System (PCS) has been approved and the preliminary design has begun for the 1st plasma PCS. This is a collaboration of many plasma control experts from existing devices to design and test plasma control techniques applicable to ITER on existing machines. The conceptual design considered all phases of plasma operation, ranging from non-active H/He plasmas through high fusion gain inductive DT plasmas to fully non-inductive steady-state operation, to ensure that the PCS control functionality and architecture can satisfy the demands of the ITER Research Plan. The PCS will control plasma equilibrium and density, plasma heat exhaust, a range of MHD instabilities (including disruption mitigation), and the non-inductive current profile required to maintain stable steady-state scenarios. The PCS architecture requires sophisticated shared actuator management and event handling systems to prioritize control goals, algorithms, and actuators according to dynamic control needs and monitor plasma and plant system events to trigger automatic changes in the control algorithms or operational scenario, depending on real-time operating limits and conditions.
Bang, Ulla; Nyberg, Lars; Rosenborg, Johan; Viby-Mogensen, Jørgen
1998-01-01
Aims It has been assumed that both plasma cholinesterase (EC 3.1.1.8) and oxidative enzymes are needed for optimum formation of the bronchodilator terbutaline from its biscarbamate prodrug bambuterol. The present study aimed at investigating the fate of bambuterol in subjects with deficient plasma cholinesterase but with normal oxidative (CYP2D6) capability. Methods The pharmacokinetics of bambuterol and terbutaline were studied in four healthy subjects (two men and two women) being homozygous for the atypical gene for plasma cholinesterase. Their oxidative metabolism was apparently good as they were all rapid metabolizers of debrisoquine. Bambuterol hydrochloride 20 mg was given orally once daily for 10 days, and plasma and urine samples were taken for 1.5 days (plasma) and 4.5 days (urine) after administration of the last dose. Results The pharmacokinetic parameters in the present study were grossly similar to those found in a study of bambuterol in subjects with normal plasma cholinesterase activity (N). However, subjects with atypical cholinesterase had a shorter terminal half-life of bambuterol (a measure of uptake rate), 4.8–12.6 h vs 8.3–22.3 h in N, and slightly higher plasma concentrations of bambuterol (average concentrations 1.9–3.7 nmol l−1vs 1.5–3.1 nmol l−1 in N). Peak/trough terbutaline plasma concentrations ratios (2.1–3.2) were somewhat increased, but average plasma concentrations (8.3–14.5 nmol l−1) and terminal half-life (16.5–21.8 h) of terbutaline did not differ. Conclusions In Caucasian populations, one subject out of 2500 is homozygous for the atypical gene for plasma cholinesterase. The atypical enzyme has a much lower affinity for bambuterol than the normal enzyme. Nevertheless, the subjects with atypical cholinesterase were able to produce terbutaline as efficiently as normal subjects. This might be explained by an altered uptake and metabolism in the absence of plasma cholinesterase, or the importance of this enzyme for the formation of terbutaline from bambuterol in vivo may have been overestimated. PMID:9643621
Yurka, Heather G; Wissler, Richard N; Zanghi, Christine N; Liu, Xiang; Tu, Xin; Eaton, Michael P
2010-07-01
Pediatric patients, particularly neonates, are at high risk for bleeding complications after cardiovascular surgery because of their immature hemostatic system, small size, and the complex operations they require. Activation of intravascular fibrinolysis is one of the principle effects of cardiopulmonary bypass that causes poor postoperative hemostasis. This complication has long been recognized and treated with antifibrinolytic medications, including the lysine analog epsilon aminocaproic acid (EACA). The therapeutic plasma concentration of EACA has been scientifically determined for the adult population, but the current recommended dosage for neonates has been empirically derived from adult studies. Therefore, we investigated the appropriate concentration of EACA for neonates undergoing bypass. We conducted an in vitro study using neonatal plasma derived from the placenta/cord units from 20 term, elective cesarean deliveries. Graded concentrations of EACA were added to aliquots of the plasma pool before activating fibrinolysis with tissue-type plasminogen activator. Standard kaolin-activated thromboelastograms were then run with the primary outcome variable being estimated percent lysis. These procedures were repeated on samples of commercially available pooled adult normal plasma for comparison. We found that neonatal plasma required significantly lower concentrations of EACA to completely prevent fibrinolysis than did adult plasma (44.2 microg/mL and 47.8 microg/mL for neonatal plasma and 94.4 and 131.4 microg/mL in adult plasma for 400 and 1000 U/mL of plasminogen activator, respectively, P < 0.001). Our data establish the minimal effective concentration of EACA necessary to completely prevent fibrinolysis in neonatal blood in vitro. This concentration is significantly less than that targeted by current dosing schemes, indicating that neonates are possibly being exposed to greater levels of EACA than is clinically necessary.
Blood Ferrokinetics in Normal Man*
Hosain, Fazle; Marsaglia, George; Finch, Clement A.
1967-01-01
The clearance of radioiron from plasma and its appearance in circulating erythrocytes in normal subjects are studied. The importance of correcting for plasma iron fluctuations and for mean body hematocrit is illustrated. The data are analyzed by probability theory to determine relationships between intravascular and extravascular iron. Two refluxes are described, one of about 7 particles of every 100 leaving the plasma, and the second of about 23. The return times of these are about 5 hours and 8 days, respectively. Images PMID:6018746
Modeling and Analysis of Alternative Concept of ITER Vacuum Vessel Primary Heat Transfer System
DOE Office of Scientific and Technical Information (OSTI.GOV)
Carbajo, Juan J; Yoder Jr, Graydon L; Dell'Orco, Giovanni
2010-01-01
A RELAP5-3D model of the ITER (Latin for the way ) vacuum vessel (VV) primary heat transfer system has been developed to evaluate a proposed design change that relocates the heat exchangers (HXs) from the exterior of the tokamak building to the interior. This alternative design protects the HXs from external hazards such as wind, tornado, and aircraft crash. The proposed design integrates the VV HXs into a VV pressure suppression system (VVPSS) tank that contains water to condense vapour in case of a leak into the plasma chamber. The proposal is to also use this water as the ultimatemore » sink when removing decay heat from the VV system. The RELAP5-3D model has been run under normal operating and abnormal (decay heat) conditions. Results indicate that this alternative design is feasible, with no effects on the VVPSS tank under normal operation and with tank temperature and pressure increasing under decay heat conditions resulting in a requirement to remove steam generated if the VVPSS tank low pressure must be maintained.« less
Finite element analysis of heat load of tungsten relevant to ITER conditions
NASA Astrophysics Data System (ADS)
Zinovev, A.; Terentyev, D.; Delannay, L.
2017-12-01
A computational procedure is proposed in order to predict the initiation of intergranular cracks in tungsten with ITER specification microstructure (i.e. characterised by elongated micrometre-sized grains). Damage is caused by a cyclic heat load, which emerges from plasma instabilities during operation of thermonuclear devices. First, a macroscopic thermo-mechanical simulation is performed in order to obtain temperature- and strain field in the material. The strain path is recorded at a selected point of interest of the macroscopic specimen, and is then applied at the microscopic level to a finite element mesh of a polycrystal. In the microscopic simulation, the stress state at the grain boundaries serves as the marker of cracking initiation. The simulated heat load cycle is a representative of edge-localized modes, which are anticipated during normal operations of ITER. Normal stresses at the grain boundary interfaces were shown to strongly depend on the direction of grain orientation with respect to the heat flux direction and to attain higher values if the flux is perpendicular to the elongated grains, where it apparently promotes crack initiation.
Gastric inhibitory polypeptide-dependent cortisol hypersecretion--a new cause of Cushing's syndrome.
Lacroix, A; Bolté, E; Tremblay, J; Dupré, J; Poitras, P; Fournier, H; Garon, J; Garrel, D; Bayard, F; Taillefer, R
1992-10-01
Corticotropin-independent nodular adrenal hyperplasia is a rare cause of Cushing's syndrome, and the factors responsible for the adrenal hyperplasia are not known. We studied a 48-year-old woman with Cushing's syndrome, nodular adrenal hyperplasia, and undetectable plasma corticotropin concentrations in whom food stimulated cortisol secretion. Cortisol secretion had an inverse diurnal rhythm in this patient, with low-to-normal fasting plasma cortisol concentrations and elevated postprandial cortisol concentrations that could not be suppressed with dexamethasone. The cortisol concentrations increased in response to oral glucose (4-fold increase) and a lipid-rich meal (4.8-fold increase) or a protein-rich meal (2.6-fold increase), but not intravenous glucose. The infusion of somatostatin blunted the plasma cortisol response to oral glucose. Intravenous infusion of gastric inhibitory polypeptide (GIP) for one hour increased the plasma cortisol concentration in the patient but not in four normal subjects. Fasting plasma GIP concentrations in the patient were similar to those in the normal subjects; feeding the patient test meals induced increases in plasma GIP concentrations that paralleled those in plasma cortisol concentrations. Cell suspensions of adrenal tissue from the patient produced more cortisol when stimulated by GIP than when stimulated by corticotropin. In contrast, adrenal cells from normal adults and fetuses or patients with cortisol-producting or aldosterone-producing adenomas responded to corticotropin but not to GIP. Nodular adrenal hyperplasia and Cushing's syndrome may be food-dependent as a result of abnormal responsiveness of adrenal cells to physiologic secretion of GIP. "Illicit" (ectopic) expression of GIP receptors on adrenal cells presumably underlies this disorder.
Effect of bedrest on circadian rhythms of plasma renin, aldosterone, and cortisol
NASA Technical Reports Server (NTRS)
Chavarri, M.; Ganguly, A.; Luetscher, J. A.; Zager, P. G.
1977-01-01
Previous studies of normal men after 5 d of bedrest showed that circulatory instability on head-up tilt or standing is preceded by increased plasma renin activity (PRA) at bedrest. In the present study, the circadian rhythms of PRA, aldosterone, and cortisol have been observed in five normal men on a constant diet. In ambulatory controls, PRA and aldosterone increased normally after standing. On the third morning of bedrest, PRA was higher than before, and at noon, PRA was higher than in standing controls. The nocturnal peaks of PRA resulting from episodic renin secretion during sleep were higher after bedrest. Plasma aldosterone was also increased by bedrest. The findings are compatible with the theory that intermittent beta-adrenergic nerve activity during sleep is increased after bedrest, but other factors, such as loss of body sodium and a lower plasma volume, may also be involved.
Decreased platelet inhibition by nitric oxide in two brothers with a history of arterial thrombosis.
Freedman, J E; Loscalzo, J; Benoit, S E; Valeri, C R; Barnard, M R; Michelson, A D
1996-01-01
Highly reactive oxygen species rapidly inactivate nitric oxide (NO), and endothelial product which inhibits platelet activation. We studied platelet inhibition by NO in two brothers with a cerebral thrombotic disorder. Both children had hyperreactive platelets, as determined by whole blood platelet aggregometry and flow cytometric analysis of the platelet surface expression of P-selectin. Mixing experiments showed that the patients'platelets behaved normally in control plasma; however, control platelets suspended in patient plasma were not inhibited by NO. As determined by flow cytometry, in the presence of plasma from either patient there was normal inhibition of the thrombin-induced expression of platelet surface P-selectin by prostacyclin, but not NO. Using a scopoletin assay, we measured a 2.7-fold increase in plasma H2O2 generation in one patient and a 3.4-fold increase in the second patient, both compared woth control plasma. Glutathione peroxidase (GSH-Px) activity was decreased in the patients' plasmas compared with control plasma. The addition of exogenous GSH-Px led to restoration of platelet inhibition by NO. These data show that, in these patients' plasmas, impaired metabolism of reactive oxygen species reduces the bioavailability of NO and impairs normal platelet inhibitory mechanisms. These findings suggest that attenuated NO-mediated platelet inhibition produced by increased reactive oxygen species or impaired antioxidant defense may cause a thrombotic disorder in humans. PMID:8613552
Warren, W B; Gurewitsch, E D; Goland, R S
1995-02-01
We hypothesized that maternal plasma corticotropin-releasing hormone levels are elevated in chronic hypertension and that elevations modulate maternal and fetal pituitary-adrenal function. Venous blood samples and 24-hour urine specimens were obtained in normal and hypertensive pregnancies at 21 to 40 weeks of gestation. Corticotropin-releasing hormone, corticotropin, cortisol, dehydroepiandrosterone sulfate, and total estriol levels were measured by radioimmunoassay. Mean hormone levels were compared by unpaired t test or two-way analysis of variance. Plasma corticotropin-releasing hormone levels were elevated early in hypertensive pregnancies but did not increase after 36 weeks. Levels of pituitary and adrenal hormones were not different in normal and hypertensive women. However, maternal plasma estriol levels were lower in hypertensive pregnancies compared with normal pregnancies. Fetal 16-hydroxy dehydroepiandrosterone sulfate, the major precursor to placental estriol production, has been reported to be lower than normal in hypertensive pregnancies, possibly explaining the decreased plasma estriol levels reported here. Early stimulation of placental corticotropin-releasing hormone production or secretion may be related to accelerated maturation of placental endocrine function in pregnancies complicated by chronic hypertension.
Valcheva-Kuzmanova, S; Kuzmanov, K; Tancheva, S; Belcheva, A
2007-03-01
Aronia melanocarpa fruit juice (AMFJ) is rich in phenolic antioxidants, especially flavonoids from the anthocyanin subclass. The aim of the present study was to investigate the influence of AMFJ on plasma glucose and lipids in diabetic rats. Diabetes was induced by an intraperitoneal injection of streptozotocin (50 mg/kg). AMFJ was applied by gavage at doses of 10 and 20 ml/kg for 6 weeks to normal and diabetic rats. Streptozotocin caused a significant elevation of plasma glucose by 141% and of plasma triglycerides (TG) by 64% in comparison with normal control rats and induced statistically insignificant elevations of total cholesterol and LDL-cholesterol and a reduction of HDL-cholesterol. Applied to normal rats, AMFJ did not influence plasma glucose and lipid levels. Applied to diabetic rats, AMFJ (10 and 20 ml/kg) significantly reduced plasma glucose by 44% and 42% and TG by 35% and 39%, respectively, to levels that did not significantly differ from those of the normal control rats and counteracted the influence of streptozotocin on total cholesterol, LDL-cholesterol and HDL-cholesterol. In conclusion, AMFJ significantly decreased the streptozotocin-induced abnormalities in blood glucose and TG in diabetic rats and might be useful in prevention and control of diabetes mellitus and diabetes-associated complications. Copyright 2007 Prous Science.
Equilibrium, confinement and stability of runaway electrons in tokamaks
DOE Office of Scientific and Technical Information (OSTI.GOV)
Spong, D A
1976-03-01
Some of the ramifications of the runaway population in tokamak experiments are investigated. Consideration is given both to the normal operating regime of tokamaks where only a small fraction of high energy runaways are present and to the strong runaway regime where runaways are thought to carry a significant portion of the toroidal current. In particular, the areas to be examined are the modeling of strong runaway discharges, single particle orbit characteristics of runaways, macroscopic beam-plasma equilibria, and stability against kink modes. A simple one-dimensional, time-dependent model has been constructed in relation to strong runaway discharges. Single particle orbits aremore » analyzed in relation to both the strong runaway regime and the weak regime. The effects of vector E x vector B drifts are first considered in strong runaway discharges and are found to lead to a slow inward shrinkage of the beam. Macroscopic beam-plasma equilibria are treated assuming a pressureless relativistic beam with inertia and using an ideal MHD approximation for the plasma. The stability of a toroidal relativistic beam against kink perturbations is examined using several models. (MOW)« less
Wang, Xin; Mu, Baozhong; Jiang, Li; Zhu, Jingtao; Yi, Shengzhen; Wang, Zhanshan; He, Pengfei
2011-12-01
Lithium fluoride (LiF) crystal is a radiation sensitive material widely used as EUV and soft x-ray detector. The LiF-based detector has high resolution, in principle limited by the point defect size, large field of view, and wide dynamic range. Using LiF crystal as an imaging detector, a resolution of 900 nm was achieved by a projection imaging of test meshes with a Schwarzschild objective operating at 13.5 nm. In addition, by imaging of a pinhole illuminated by the plasma, an EUV spot of 1.5 μm diameter in the image plane of the objective was generated, which accomplished direct writing of color centers with resolution of 800 nm. In order to avoid sample damage and contamination due to the influence of huge debris flux produced by the plasma source, a spherical normal-incidence condenser was used to collect EUV radiation. Together with a description of experimental results, the development of the Schwarzschild objective, the influence of condenser on energy density and the alignment of the imaging system are also reported.
Schwille, P O; Schmiedl, A; Schwille, R; Brunner, P; Kissler, H; Cesnjevar, R; Gepp, H
2003-03-01
Calcifications in arterial media are clinically well documented, but the role played by magnesium in pathophysiology and therapy is uncertain. To clarify this, an animal model in which the juxtacardial aorta was grafted to the infrarenal aorta, and the subsequent calcifications in the media of the graft and their response to oral supplementation with three magnesium-containing and alkalinizing preparations was investigated. Groups of highly inbred rats were formed as follows: sham-operation (Sham, n = 12), aorta transplantation (ATx, n = 12), ATx + magnesium citrate (MgC, n = 12), ATx + MgC + potassium citrate (MgCPC, n = 12), ATx + MgC + MgCPC (MgCPCSB, n = 12). At 84 (+/-2) days after ATx with or without treatment the following observations were made: (1) weight gain and general status were normal; (2) ATx rats developed massive media calcification, mineral accumulation in the graft, decreased erythrocyte magnesium and plasma parathyroid hormone, and increased plasma ionized magnesium and calcium, and uric acid; (3) Mg-treated rats developed variable degrees of metabolic alkalosis, but only MgCPCSB supplementation prevented calcifications. Additional findings after ATx alone were: imbalance in endothelin and nitric oxide production, the mineral deposited in media was poorly crystallized calcium phosphate, calcium exchange between plasma and graft, and bone resorption were unchanged. The superior anti-calcification effect of MgCPCSB was characterized by complete restoration of normal extracellular mineral homeostasis and uric acid, but sub-optimal normalization of erythrocyte magnesium. It was concluded that in the rat: (1) ATx causes loss of cellular magnesium, excess of extracellular magnesium and calcium in the presence of apparently unchanged bone resorption, and increased uricemia; (2) ATx facilitates enhanced influx of calcium into vascular tissue, leading to calcium phosphate deposition in the media; (3) ATx-induced calcification is prevented by dietary supplementation with a combination of magnesium, alkali citrate and bases. Although the described circulatory model of media calcification in the rat requires further investigation, the data allow ascribing a fundamental role to magnesium and acid-base metabolism.
Napoli, R; Davalli, A M; Hirshman, M F; Weitgasser, R; Weir, G C; Horton, E S
1996-01-01
Chronic insulin therapy improves but does not restore impaired insulin-mediated muscle glucose uptake in human diabetes or muscle glucose uptake, transport, and transporter translocation in streptozocin diabetic rats. To determine whether this inability is due to inadequate insulin replacement, we studied fasted streptozocin-induced diabetic Lewis rats either untreated or after islet transplantation under the kidney capsule. Plasma glucose was increased in untreated diabetics and normalized by the islet transplantation (110 +/- 5, 452 +/- 9, and 102 +/- 3 mg/dl in controls, untreated diabetics, and transplanted diabetics, respectively). Plasma membrane and intracellular microsomal membrane vesicles were prepared from hindlimb skeletal muscle of basal and maximally insulin-stimulated rats. Islet transplantation normalized plasma membrane carrier-mediated glucose transport Vmax, plasma membrane glucose transporter content, and insulin-induced transporter translocation. There were no differences in transporter intrinsic activity (Vmax/Ro) among the three groups. Microsomal membrane GLUT4 content was reduced by 30% in untreated diabetic rats and normal in transplanted diabetics, whereas the insulin-induced changes in microsomal membrane GLUT4 content were quantitatively similar in the three groups. There were no differences in plasma membrane GLUT1 among the groups and between basal and insulin stimulated states. Microsomal membrane GLUT1 content was increased 60% in untreated diabetics and normalized by the transplantation. In conclusion, an adequate insulin delivery in the peripheral circulation, obtained by islet transplantation, fully restores the muscle glucose transport system to normal in streptozocin diabetic rats. PMID:8617870
Meyer, R A; Meyer, M H; Gray, R W; Bruns, M E
1987-02-01
X-linked hypophosphatemic (Hyp) mice are a model for human sex-linked vitamin D-resistant rickets. We have reported intestinal malabsorption of calcium in young Hyp mice, and in this report we have explored the mechanism for it. To test for resistance of the intestine to 1,25(OH)2 vitamin D3, this hormone was continually infused via osmotic minipumps into 4-week-old normal and Hyp mice at 0, 17, 50 or 150 ng/kg/day. After 3 days, 45Ca and inorganic 32P were administered by gavage, and the mice were sacrificed on the fifth day. The Hyp mice showed responses to the hormone equivalent to the normal mice in terms of increased intestinal absorption of both 45Ca and 32P, increased plasma isotope levels, increased femoral isotope content, and increased duodenal and renal 9 kD vitamin D-dependent calcium-binding protein (calbindin-D9K; CaBP). Plasma 1,25(OH)2D was measured in these mice. There were significant correlations of plasma 1,25(OH)2D to the intestinal absorption of 45Ca and 32P and to duodenal and renal CaBP. Plasma 1,25(OH)2D was also measured in stock normal and Hyp mice and was found to be lower in 4-week-old Hyp mice than in 4-week-old normal mice (113 +/- 10 pM (n = 18) vs. 67 +/- 10 (n = 20), normal vs. Hyp, p less than .01), but unchanged at 13 weeks of age (77 +/- 13 (n = 13) vs. 70 +/- 15 (n = 15), NS). This observed difference in plasma 1,25(OH)2D between normal and Hyp mice at 4 weeks of age was sufficient to explain the observed normal-to-Hyp differences in intestinal absorption of 45Ca and duodenal and renal CaBP. It also explained 72 +/- 18% of the observed difference in 32P absorption. We conclude that Hyp mouse intestine is not resistant to 1,25(OH)2D and that the lower plasma 1,25(OH)2D of 4-week-old Hyp mice causes intestinal malabsorption of calcium and phosphate.
The Role of Combined ICRF and NBI Heating in JET Hybrid Plasmas in Quest for High D-T Fusion Yield
NASA Astrophysics Data System (ADS)
Mantsinen, Mervi; Challis, Clive; Frigione, Domenico; Graves, Jonathan; Hobirk, Joerg; Belonohy, Eva; Czarnecka, Agata; Eriksson, Jacob; Gallart, Dani; Goniche, Marc; Hellesen, Carl; Jacquet, Philippe; Joffrin, Emmanuel; King, Damian; Krawczyk, Natalia; Lennholm, Morten; Lerche, Ernesto; Pawelec, Ewa; Sips, George; Solano, Emilia R.; Tsalas, Maximos; Valisa, Marco
2017-10-01
Combined ICRF and NBI heating played a key role in achieving the world-record fusion yield in the first deuterium-tritium campaign at the JET tokamak in 1997. The current plans for JET include new experiments with deuterium-tritium (D-T) plasmas with more ITER-like conditions given the recently installed ITER-like wall (ILW). In the 2015-2016 campaigns, significant efforts have been devoted to the development of high-performance plasma scenarios compatible with ILW in preparation of the forthcoming D-T campaign. Good progress was made in both the inductive (baseline) and the hybrid scenario: a new record JET ILW fusion yield with a significantly extended duration of the high-performance phase was achieved. This paper reports on the progress with the hybrid scenario which is a candidate for ITER longpulse operation (˜1000 s) thanks to its improved normalized confinement, reduced plasma current and higher plasma beta with respect to the ITER reference baseline scenario. The combined NBI+ICRF power in the hybrid scenario was increased to 33 MW and the record fusion yield, averaged over 100 ms, to 2.9x1016 neutrons/s from the 2014 ILW fusion record of 2.3x1016 neutrons/s. Impurity control with ICRF waves was one of the key means for extending the duration of the high-performance phase. The main results are reviewed covering both key core and edge plasma issues.
NASA Astrophysics Data System (ADS)
Moreau, D.; Artaud, J. F.; Ferron, J. R.; Holcomb, C. T.; Humphreys, D. A.; Liu, F.; Luce, T. C.; Park, J. M.; Prater, R.; Turco, F.; Walker, M. L.
2015-06-01
This paper shows that semi-empirical data-driven models based on a two-time-scale approximation for the magnetic and kinetic control of advanced tokamak (AT) scenarios can be advantageously identified from simulated rather than real data, and used for control design. The method is applied to the combined control of the safety factor profile, q(x), and normalized pressure parameter, βN, using DIII-D parameters and actuators (on-axis co-current neutral beam injection (NBI) power, off-axis co-current NBI power, electron cyclotron current drive power, and ohmic coil). The approximate plasma response model was identified from simulated open-loop data obtained using a rapidly converging plasma transport code, METIS, which includes an MHD equilibrium and current diffusion solver, and combines plasma transport nonlinearity with 0D scaling laws and 1.5D ordinary differential equations. The paper discusses the results of closed-loop METIS simulations, using the near-optimal ARTAEMIS control algorithm (Moreau D et al 2013 Nucl. Fusion 53 063020) for steady state AT operation. With feedforward plus feedback control, the steady state target q-profile and βN are satisfactorily tracked with a time scale of about 10 s, despite large disturbances applied to the feedforward powers and plasma parameters. The robustness of the control algorithm with respect to disturbances of the H&CD actuators and of plasma parameters such as the H-factor, plasma density and effective charge, is also shown.
Dib, N; Kiciak, A; Pietrzak, P; Ferenc, K; Jaworski, P; Kapica, M; Tarnowski, W; Zabielski, R
2013-10-01
Bariatric surgery consists in duodenal exclusion from the food passage in obese patients with coexistent type 2 diabetes. Nowadays bariatric surgery is considered the most effective method of glycemic index normalization and insulin resistance reduction. Recent results on obese and non-obese rats showed remission of type 2 diabetes symptoms within few days after the surgery. The aim of the present work was to analyze the mechanisms of neuro-hormonal regulation responsible for early normalization of metabolic syndrome after bariatric surgery. In present study the concentration of selected intestinal hormones and adipokines in blood plasma and gastrointestinal tissues were analyzed. Study was conducted on Wistar rats. Animals were divided into three groups (each n=6): control (SH) shame-operated rats; animals in which visceral fat tissue was extracted (LP); and rats in which Scopinaro bariatric surgery was performed (BPD). Immunochemistry analysis of blood plasma showed decrease of insulin concentration in BPD and LP and increase of polypeptide YY (PYY) in BPD group as compared to the control. In duodenal mucosa homogenates the tendency to reduce insulin in LP and BPD group, and increase PYY and visfatin in BPD group was observed. Histometry analysis showed reduction of mucosa thickness in excluded segments of gastrointestinal tract in BPD group as compared to the SH and LP. Concluding, model studies on rats allowed better understanding of mechanisms important for early normalization of glycemic index and insulin resistance reduction in rats.
Free Fall Plasma-Arc Reactor for Synthesis of Carbon Nanotubes in Microgravity
NASA Technical Reports Server (NTRS)
Alford, J. M.; Mason, G. R.; Feinkema, D. A.
2006-01-01
High temperatures inside the plasma of a carbon arc generate strong buoyancy driven convection which has an effect on the growth and morphology of the single-walled carbon nanotubes (SWNTs). To study the effect of buoyancy on the arc process, a miniature carbon arc apparatus was designed and developed to synthesize SWNTs in a microgravity environment substantially free from buoyant convective flows. An arc reactor was operated in the 2.2- and 5.18-second drop towers at the NASA Glenn Research Center. The apparatus employed a 4 mm diameter anode and was powered by a portable battery pack capable of providing in excess of 300 amps at 30 volts to the arc for the duration of a 5-second drop. However, the principal result is that no dramatic difference in sample yield or composition was noted between normal gravity, 2.2-and 5-second long microgravity runs.
Responsivity calibration of the LoWEUS spectrometer
Lepson, J. K.; Beiersdorfer, P.; Kaita, R.; ...
2016-09-02
We performed an in situ calibration of the relative responsivity function of the Long-Wavelength Extreme Ultraviolet Spectrometer (LoWEUS), while operating on the Lithium Tokamak Experiment (LTX) at Princeton Plasma Physics Laboratory. The calibration was accomplished by measuring oxygen lines, which are typically present in LTX plasmas. The measured spectral line intensities of each oxygen charge state were then compared to the calculated emission strengths given in the CHIANTI atomic database. Normalizing the strongest line in each charge state to the CHIANTI predictions, we obtained the differences between the measured and predicted values for the relative strengths of the other linesmore » of a given charge state. We find that a 3rd degree polynomial function provides a good fit to the data points. Lastly, our measurements show that the responsivity between about 120 and 300 Å varies by factor of ~30.« less
The Effect of Interchanging the Polarity of the Dense Plasma Focus on Neutron Yield
NASA Astrophysics Data System (ADS)
Jiang, Sheng; Higginson, Drew; Link, Anthony; Schmidt, Andrea
2017-10-01
The dense plasma focus (DPF) Z-pinch devices can serve as portable neutron sources when deuterium is used as the filling gas. DPF devices are normally operated with the inner electrode as the anode. It has been found that interchanging the polarity of the electrodes can cause orders of magnitude decrease in the neutron yield. Here we use the particle-in-cell (PIC) code LSP to model a DPF with both polarities. We have found the difference in the shape of the sheath, the voltage and current traces, and the electric and magnetic fields in the pinch region due to different polarities. A detailed comparison will be presented. Prepared by LLNL under Contract DE-AC52-07NA27344 and supported by the Laboratory Directed Research and Development Program (15-ERD-034) at LLNL. Computing support for this work came from the LLNL Institutional Computing Grand Challenge program.
Brusilow, Saul W; Cooper, Arthur J L
2011-11-01
Hyperammonemia is a major contributing factor to the encephalopathy associated with liver disease. It is now generally accepted that hyperammonemia leads to toxic levels of glutamine in astrocytes. However, the mechanism by which excessive glutamine is toxic to astrocytes is controversial. Nevertheless, there is strong evidence that glutamine-induced osmotic swelling, especially in acute liver failure, is a contributing factor: the osmotic gliopathy theory. The object of the current communication is to present evidence for the osmotic gliopathy theory in a hyperammonemic patient who overdosed on acetaminophen. Case report. Johns Hopkins Hospital. A 22-yr-old woman who, 36 hrs before admission, ingested 15 g acetaminophen was admitted to the Johns Hopkins Hospital. She was treated with N-acetylcysteine. Physical examination was unremarkable; her mental status was within normal limits and remained so until approximately 72 hrs after ingestion when she became confused, irritable, and agitated. She was intubated, ventilated, and placed on lactulose. Shortly thereafter, she was noncommunicative, unresponsive to painful stimuli, and exhibited decerebrate posturing. A clinical diagnosis of cerebral edema and increased intracranial pressure was made. She improved very slowly until 180 hrs after ingestion when she moved all extremities. She woke up shortly thereafter. Despite the fact that hyperammonemia is a major contributing factor to the encephalopathy observed in acute liver failure, the patient's plasma ammonia peaked when she exhibited no obvious neurologic deficit. Thereafter, her plasma ammonia decreased precipitously in parallel with a worsening neurologic status. She was deeply encephalopathic during a period when her liver function and plasma ammonia had normalized. Plasma glutamine levels in this patient were high but began to normalize several hours after plasma ammonia had returned to normal. The patient only started to recover as her plasma glutamine began to return to normal. We suggest that the biochemical data are consistent with the osmotic gliopathy theory--high plasma ammonia leads to high plasma glutamine--an indicator of excess glutamine in astrocytes (the site of brain glutamine synthesis). This excess glutamine leads to osmotic stress in these cells. The lag in recovery of brain function presumably reflects time taken for the astrocyte glutamine concentration to return to normal. We hypothesize that an inhibitor of brain glutamine synthesis may be an effective treatment modality for acute liver failure.
Brusilow, Saul W; Cooper, Arthur J.L.
2011-01-01
Objective Hyperammonemia is a major contributing factor to the encephalopathy associated with liver disease. It is now generally accepted that hyperammonemia leads to toxic levels of glutamine in astrocytes. However, the mechanism by which excessive glutamine is toxic to astrocytes is controversial. Nevertheless, there is strong evidence that glutamine-induced osmotic swelling, especially in acute liver failure (ALF), is a contributing factor – the osmotic gliopathy theory. The object of the current communication is to present evidence for the osmotic gliopathy theory in a hyperammonemic patient who overdosed on acetaminophen. Design Case report. Setting Johns Hopkins Hospital. Patient A 22-year old white female who, 36 hours prior to admission, ingested 15 grams of acetaminophen was admitted to the Johns Hopkins Hospital. Physical examination was unremarkable; her mental status was within normal limits and remained so until approximately 72 hours after ingestion when she became confused, irritable and agitated. Interventions She was intubated, ventilated and placed on lactulose. Shortly thereafter she was non-communicative, unresponsive to painful stimuli and exhibited decerebrate posturing. A clinical diagnosis of cerebral edema and increased intracranial pressure (ICP) was made. She improved very slowly until 180 hours after ingestion when she moved all extremities. She woke up shortly thereafter. Measurements and main results Despite the fact that hyperammonemia is a major contributing factor to the encephalopathy observed in ALF the patient’s plasma ammonia peaked when she exhibited no obvious neurological deficit. Thereafter, her plasma ammonia decreased precipitously in parallel with a worsening neurological status. She was deeply encephalopathic during a period when her liver function and plasma ammonia had normalized. Plasma glutamine levels in this patient were high, but began to normalize several hours after plasma ammonia had returned to normal. The patient only commenced to recover as her plasma glutamine began to return to normal. Conclusions We suggest that the biochemical data are consistent with the osmotic gliopathy theory – high plasma ammonia leads to high plasma glutamine – an indicator of excess glutamine in astrocytes (the site of brain glutamine synthesis). This excess glutamine leads to osmotic stress in these cells. The lag in recovery of brain function presumably reflects time taken for the astrocyte glutamine concentration to return to normal. We hypothesize that an inhibitor of brain glutamine synthesis may be an effective treatment modality for ALF. PMID:21705899
NASA Astrophysics Data System (ADS)
Walker, Jonathan; Heinrich, Jonathon; Font, Gabriel; Ebersohn, Frans; Garrett, Michael
2017-10-01
A 100 kW class lanthanum-hexaboride plasma source is under continuing development for the Lockheed Martin Compact Fusion Reactor program. The current experiment, T4B, has become a test bed for plasma source operation with the goal of creating a high density plasma target for neutral beam heating. We present operation and performance of different plasma source geometries, results of plasma source coupling, and future plasma source development plans. ©2017 Lockheed Martin Corporation. All Rights Reserved.
Koopmans, Sietse Jan; Ruis, Marko; Dekker, Ruud; van Diepen, Hans; Korte, Mechiel; Mroz, Zdzislaw
2005-07-21
Social stress occurs in intensive pig farming due to aggressive behavior. This stress may be reduced at elevated dietary levels of tryptophan (TRP). In this study, we compared the effects of high (13.2%) vs. normal (3.4%) dietary TRP to large neutral amino acid (LNAA) ratios on behavior and stress hormones in catheterized pigs ( approximately 50 kg BW), which were exposed to social stress by placing them twice into the territory of a dominant pig ( approximately 60 kg) for 15 min. Pre-stress plasma TRP concentrations were 156+/-15 vs. 53+/-6 micromol/l (p<0.01) in pigs on the high vs. normal TRP diets, respectively. Pre-stress plasma cortisol and noradrenaline concentrations were twofold (p<0.01) and 1.4-fold (p<0.05) lower but plasma adrenaline concentration was similar in pigs on the high vs. normal TRP diets, respectively. During the social confrontations, pigs on the high vs. normal TRP diets show a tendency towards reduced active avoidance behavior (3.2+/-1.1 vs. 6.7+/-1.2 min, p<0.1) but their physical activity (8.5+/-0.6 vs. 10.2+/-0.8 min) and aggressive attitude towards the dominant pig (11+/-3 vs. 7+/-2 times biting) were similar. Immediate (+5 min) post-stress plasma cortisol, noradrenaline and adrenaline responses were similar among dietary groups. After the social confrontations, the post-stress plasma cortisol, noradrenaline and adrenaline concentrations and/or curves (from +5 min to 2 h) were lower/steeper (p<0.05) in pigs on the high vs. normal TRP diets. In summary, surplus TRP in diets for pigs (1) does not significantly affect behavior when exposed to social stress, (2) reduces basal plasma cortisol and noradrenaline concentrations, (3) does not affect the immediate hormonal response to stress, and (4) reduces the long-term hormonal response to stress. In general, pigs receiving high dietary TRP were found to be less affected by stress.
An, Jing; Hu, Fangdi; Wang, Changhong; Zhang, Zijia; Yang, Li; Wang, Zhengtao
2016-09-01
1. Pinoresinol di-O-β-d-glucopyranoside (PDG), geniposide (GE), geniposidic acid (GA), aucubin (AN) and chlorogenic acid (CA) are the representative active ingredients in Eucommiae cortex (EC), which may be estrogenic. 2. The ultra high-performance liquid chromatography/tandem mass spectrometry (UHPLC-MS/MS) method for simultaneous determination of the five ingredients showed good linearity, low limits of quantification and high extraction recoveries, as well as acceptable precision, accuracy and stability in mice plasma and tissue samples (liver, spleen, kidney and uterus). It was successfully applied to the comparative study on pharmacokinetics and tissue distribution of PDG, GE, GA, AN and CA between normal and ovariectomized (OVX) mice. 3. The results indicated that except CA, the plasma and tissue concentrations of PDG, GE, GA in OVX mice were all greater than those in normal mice. AN could only be detected in the plasma and liver homogenate of normal mice, which was poorly absorbed in OVX mice and low in other measured tissues. PDG, GE and GA seem to be better absorbed in OVX mice than in normal mice proved by the remarkable increased value of AUC0-∞ and Cmax. It is beneficial that PDG, GE, GA have better plasma absorption and tissue distribution in pathological state.
Plasma choline and betaine and their relation to plasma homocysteine in normal pregnancy.
Velzing-Aarts, Francien V; Holm, Pål I; Fokkema, M Rebecca; van der Dijs, Fey P; Ueland, Per M; Muskiet, Frits A
2005-06-01
Plasma concentrations of total homocysteine (tHcy) decrease during pregnancy. This reduction has been investigated in relation to folate status, but no study has addressed the possible role of betaine and its precursor choline. We investigated the courses of plasma choline and betaine during normal human pregnancy and their relations to plasma tHcy. Blood samples were obtained monthly; the initial samples were taken at gestational week (GW) 9, and the last samples were taken approximately 3 mo postpartum. The study population comprised 50 women of West African descent. Most of the subjects took folic acid irregularly. Plasma choline (geometric x; 95% reference interval) increased continuously during pregnancy, from 6.6 (4.5, 9.7) micromol/L at GW 9 to 10.8 (7.4, 15.6) micromol/L at GW 36. Plasma betaine decreased in the first half of pregnancy, from 16.3 (8.6, 30.8) micromol/L at GW 9 to 10.3 (6.6, 16.2) micromol/L at GW 20 and remained constant thereafter. We confirmed a reduction in plasma tHcy, and the lowest concentration was found in the second trimester. From GW 16 onward, an inverse relation between plasma tHcy and betaine was observed. Multiple regression analysis showed that plasma betaine was a strong predictor of plasma tHcy from GW 20 onward. The steady increase in choline throughout gestation may ensure choline availability for placental transfer with subsequent use by the growing fetus. Betaine becomes a strong predictor of tHcy during the course of pregnancy. Both of these findings emphasize the importance of choline and betaine status during normal human pregnancy.
Maunder, E M; Pillay, A V; Care, A D
1987-10-01
An i.v. injection of calcitriol (1,25-(OH)2D3) had no effect within 2.5 h on plasma concentrations of calbindin-D9K (vitamin D-induced calcium-binding protein; CaBP) in hypocalcaemic pigs with inherited vitamin D-dependent rickets type I or in their normocalcaemic siblings or half-siblings. Three days later the plasma concentration of CaBP had doubled in the hypocalcaemic pigs, but was unaltered in the normocalcaemic siblings and half-siblings. Following daily i.v. injections of 1,25-(OH)2D3 for a further 5 days (days 4-8) plasma concentrations of CaBP increased in both the hypocalcaemic (days 4-8) and normocalcaemic (day 8) pigs, the effect being more rapid and greater in the hypocalcaemic 1,25-(OH)2D3-deficient animals. An i.v. injection of 1,25-(OH)2D3 to pure Yucatan pigs also had no effect on plasma concentrations of CaBP within 1.5 h, but in the following 1 h there was some indication of an increase in plasma CaBP levels. In contrast to the normal pigs, insulin-induced hypoglycaemia did not lead to a peak in plasma CaBP concentrations in the hypocalcaemic pigs. There was also no change in the plasma concentrations of 1,25-(OH)2D3 associated with the peak in plasma CaBP following insulin-induced hypoglycaemia in normocalcaemic pigs. These results suggest that changes in plasma concentrations of 1,25-(OH)2D3 are not directly involved in mediating the increase in plasma CaBP which follows hypoglycaemia induced by insulin in normal pigs, although 1,25-(OH)2D3 probably plays a permissive role.
Congenital gonadotropin deficiency in boys: management during childhood.
Adan, L; Couto-Silva, A C; Trivin, C; Metz, C; Brauner, R
2004-02-01
To analyze the features of boys with congenital gonadotropin deficiency (CGD), and to determine the value of plasma inhibin B and anti-Müllerian hormone (AMH) for predicting testicular function and the effect of testosterone treatment. We followed 19 boys for CGD, including five with Kallmann syndrome. The boys were seen before 14 years of age for micropenis (9 boys) or later for delayed puberty (10 boys). No testis was palpable in the scrotum in 13 patients, bilaterally in seven of them. Luteinizing hormone (LH) peak after a gonadotropin releasing hormone (GnRH) test was between 0.5 and 5.6 U/l. Plasma inhibin B was low in the four patients evaluated at less than 1 year old. AMH was low in one of them and normal in four others. Of the older patients, three lad low plasma inhibin B and four had normal concentrations; plasma AMH was low in three of them and increased in four. Testosterone treatment restored penis length to normal in all patients. Low plasma inhibin B and AMH concentrations may indicate testicular damage in boys with CGD.
Briffa, Jessica F.; O'Dowd, Rachael; Moritz, Karen M.; Romano, Tania; Jedwab, Lisa R.; McAinch, Andrew J.; Hryciw, Deanne H.
2017-01-01
Key points Uteroplacental insufficiency compromises maternal mammary development, milk production and pup organ development; this is ameliorated by cross‐fostering, which improves pup growth and organ development and prevents adult diseases in growth‐restricted (Restricted) offspring by enhancing postnatal nutrition.Leptin is transported to the fetus from the mother by the placenta; we report reduced plasma leptin concentrations in Restricted fetuses associated with sex‐specific alterations in placental leptin transporter expression.Pup plasma leptin concentrations were also reduced during suckling, which may suggest reduced milk leptin transport or leptin reabsorption.Mothers suckled by Restricted pups had impaired mammary development and changes in milk fatty acid composition with no alterations in milk leptin; cross‐fostering restored pup plasma leptin concentrations, which may be correlated to improved milk composition and intake.Increased plasma leptin and altered milk fatty acid composition in Restricted pups suckling mothers with normal lactation may improve postnatal growth and prevent adult diseases. Abstract Uteroplacental insufficiency reduces birth weight and adversely affects fetal organ development, increasing adult disease risk. Cross‐fostering improves postnatal nutrition and restores these deficits. Mothers with growth‐restricted pups have compromised milk production and composition; however, the impact cross‐fostering has on milk production and composition is unknown. Plasma leptin concentrations peak during the completion of organogenesis, which occurs postnatally in rats. Leptin is transferred to the fetus via the placenta and to the pup via the lactating mammary gland. This study investigated the effect of uteroplacental insufficiency on pup plasma leptin concentrations and placental leptin transporters. We additionally examined whether cross‐fostering improves mammary development, milk composition and pup plasma leptin concentrations. Fetal growth restriction was induced by bilateral uterine vessel ligation surgery on gestation day 18 in Wistar Kyoto rats (termed uteroplacental insufficiency surgery mothers). Growth‐restricted (Restricted) fetuses had reduced plasma leptin concentrations, persisting throughout lactation, and sex‐specific alterations in placental leptin transporters. Mothers suckled by Restricted pups had impaired mammary development, altered milk fatty acid composition and increased plasma leptin concentrations, despite no changes in milk leptin. Milk intake was reduced in Restricted pups suckling uteroplacental insufficiency surgery mothers compared to Restricted pups suckling sham‐operated mothers. Cross‐fostering Restricted pups onto a sham‐operated mother improved postnatal growth and restored plasma leptin concentrations compared to Restricted pups suckling uteroplacental insufficiency surgery mothers. Uteroplacental insufficiency alters leptin homeostasis. This is ameliorated with cross‐fostering and enhanced milk fatty acid composition and consumption, which may protect the pups from developing adverse health conditions in adulthood. PMID:28369926
[Beta-endorphin and obesity. Possible pathogenetic implications].
Giugliano, D; Saccomanno, F; Quatraro, A; Ceriello, A; Torella, R
1990-01-01
Several experimental data have documented the ability of both opiates and opioid peptides to stimulate food intake. On the other hand, the plasma beta-endorphin levels found in obese patients are higher than those observed in normal-weight controls, which may have pathogenetic implications. We have investigated the responses of plasma glucose, insulin, C-peptide and glucagon to an infusion of human beta-endorphin in formerly obese subjects who had obtained by dieting the normalization of body weight and in lean controls. The data show that: a) the increased plasma beta-endorphin concentrations found in human obesity are not corrected by normalization of body weight; b) formerly obese subjects behave as obese subjects in their metabolic and hormonal responses to beta-endorphin.
Evaluating optical hazards from plasma arc cutting.
Glassford, Eric; Burr, Gregory
2018-01-01
The Health Hazard Evaluation Program of the National Institute for Occupational Safety and Health evaluated a steel building materials manufacturer. The employer requested the evaluation because of concerns about optical radiation hazards from a plasma arc cutting system and the need to clarify eye protection requirements for plasma operators, other employees, and visitors. The strength of the ultraviolet radiation, visible radiation (light), and infrared radiation generated by the plasma arc cutter was measured at various distances from the source and at different operating amperages. Investigators also observed employees performing the plasma arc cutting. Optical radiation above safe levels for the unprotected eyes in the ultraviolet-C, ultraviolet-B, and visible light ranges were found during plasma arc cutting. In contrast, infrared and ultraviolet-A radiation levels during plasma arc cutting were similar to background levels. The highest non-ionizing radiation exposures occurred when no welding curtains were used. A plasma arc welding curtain in place did not eliminate optical radiation hazards to the plasma arc operator or to nearby employees. In most instances, the measured intensities for visible light, UV-C, and UV-B resulted in welding shade lens numbers that were lower than those stipulated in the OSHA Filter Lenses for Protection Against Radiant Energy table in 29 CFR 1910.133(a)(5). [1] Investigators recommended using a welding curtain that enclosed the plasma arc, posting optical radiation warning signs in the plasma arc cutter area, installing audible or visual warning cues when the plasma arc cutter was operating, and using welding shades that covered the plasma arc cutter operator's face to protect skin from ultraviolet radiation hazards.
George, Jack M.; Wolff, Sheldon M.; Diller, Esther; Bartter, Frederic C.
1969-01-01
A sensitive method for determination of plasma unconjugated etiocholanolone by double-isotope-derivative dilution has been described. The mean values for normal subjects was 0.038±0.003 (SEM) μg/100 ml. 40 patients, 20 with familial Mediterranean fever and 20 with other diseases characterized by recurrent fever were studied. The over-all mean concentration of plasma unconjugated etiocholanolone for the patients (febrile or afebrile) was 0.101 ±0.012 μg/100 ml, significantly above that of normals. Mean plasma values for the patients while they were febrile did not differ from the mean values when they were afebrile. It is suggested that the concentration of plasma unconjugated etiocholanolone is not related to fever in these patients. PMID:4886315
A semi-micromethod for determination of oxalate in human plasma.
Porowski, Tadeusz; Gałasiński, Władysław
2003-01-01
An enzymatic semi-micromethod for oxalate determination in human plasma was elaborated. The principle of the method depends on the oxalate isolation from deproteinized plasma, following determination by the calorimetric oxalate oxidase-peroxidase-indamine system. This method protects against internal oxalate losses and excludes an interference of contaminations. Results, obtained by this method, were reliable and ideally suited for use as real normal values (less than or equal to 6 microM) of oxalate content in the plasma of healthy individuals. The elaborated method, which can assay plasma oxalate accurately in normal individuals as well as in hyperoxalemic conditions is superior to those previously used. The procedure of semi-micromethod does not require expensive equipments and apparatus: it is simple and easy to perform in every laboratory and takes little time.
García Robles, Reggie; Rojas, Juan Diego; Bermúdez, Martha; Bernal, Jaime
2012-01-01
Objective: to quantify placenta-specific RNA in plasma of women carrying foetuses with intrauterine growth restriction and pregnant women with normal pregnancies. Methods: 8 pregnant women with foetuses with intrauterine growth restriction were studied as well as 18 women with uncomplicated pregnancies in the third pregnancy trimester. Total free RNA was quantified in maternal plasma by spectrophotometry and the gene expression of hPL (Human Placental Lactogen) at the messenger RNA level through technical Real Time-Chain Reaction Polymerase. Results: plasma RNA of fetoplacental origin was successfully detected in 100% of pregnant women. There were no statistically significant differences between the values of total RNA extracted from plasma (p= 0.5975) nor in the messenger RNA expression of hPL gene (p= 0.5785) between cases and controls. Conclusion: messenger RNA of fetoplacental origin can be detected in maternal plasma during pregnancy. PMID:24893189
Ayala Ramírez, Paola; García Robles, Reggie; Rojas, Juan Diego; Bermúdez, Martha; Bernal, Jaime
2012-07-01
to quantify placenta-specific RNA in plasma of women carrying foetuses with intrauterine growth restriction and pregnant women with normal pregnancies. 8 pregnant women with foetuses with intrauterine growth restriction were studied as well as 18 women with uncomplicated pregnancies in the third pregnancy trimester. Total free RNA was quantified in maternal plasma by spectrophotometry and the gene expression of hPL (Human Placental Lactogen) at the messenger RNA level through technical Real Time-Chain Reaction Polymerase. plasma RNA of fetoplacental origin was successfully detected in 100% of pregnant women. There were no statistically significant differences between the values of total RNA extracted from plasma (p= 0.5975) nor in the messenger RNA expression of hPL gene (p= 0.5785) between cases and controls. messenger RNA of fetoplacental origin can be detected in maternal plasma during pregnancy.
Performance modelling of plasma microthruster nozzles in vacuum
NASA Astrophysics Data System (ADS)
Ho, Teck Seng; Charles, Christine; Boswell, Rod
2018-05-01
Computational fluid dynamics and plasma simulations of three geometrical variations of the Pocket Rocket radiofrequency plasma electrothermal microthruster are conducted, comparing pulsed plasma to steady state cold gas operation. While numerical limitations prevent plasma modelling in a vacuum environment, results may be obtained by extrapolating from plasma simulations performed in a pressurised environment, using the performance delta from cold gas simulations performed in both environments. Slip regime boundary layer effects are significant at these operating conditions. The present investigation targets a power budget of ˜10 W for applications on CubeSats. During plasma operation, the thrust force increases by ˜30% with a power efficiency of ˜30 μNW-1. These performance metrics represent instantaneous or pulsed operation and will increase over time as the discharge chamber attains thermal equilibrium with the heated propellant. Additionally, the sculpted nozzle geometry achieves plasma confinement facilitated by the formation of a plasma sheath at the nozzle throat, and fast recombination ensures a neutral exhaust plume that avoids the contamination of solar panels and interference with externally mounted instruments.
Recent Progress on Spherical Torus Research and Implications for Fusion Energy Development Path
NASA Astrophysics Data System (ADS)
Ono, Masayuki
2014-10-01
The spherical torus or spherical tokamak (ST) is a member of the tokamak family with its aspect ratio (A =R0 / a) reduced to A near 1.5, well below the normal tokamak operating range of A equal to 2.5 or greater. As the aspect ratio is reduced, the ideal tokamak beta (radio of plasma to magnetic pressure) stability limit increases rapidly, approximately as 1/A. The plasma current it can sustain for a given edge safety factor q-95 also increases rapidly. Because of the above, as well as the natural plasma elongation which makes its plasma shape appear spherical, the ST configuration can yield exceptionally high tokamak performance in a compact geometry. Due to its compactness and high performance, the ST configuration has various near term applications, including a compact fusion neutron source with low tritium consumption, in addition to the longer term goal of an attractive fusion energy power source. Since the start of the two mega-ampere class ST facilities in 2000, the National Spherical Torus Experiment (NSTX) in the US and Mega Ampere Spherical Tokamak (MAST) in the UK, active ST research has been conducted worldwide. More than sixteen ST research facilities operating during this period have achieved remarkable advances in all areas of fusion research, including fundamental fusion energy science as well as technological innovation. These results suggest exciting future prospects for ST research in both the near and longer term. The talk will summarize the key physics results from worldwide ST experiments, and describe ST community plans to provide the database for FNSF design while improving predictive capabilities for ITER and beyond. This work supported by DoE Contract No. DE-AC02-09CH11466.
Factors influencing brain natriuretic peptide levels in healthy pregnant women.
Mayama, Michinori; Yoshihara, Masato; Uno, Kaname; Tano, Sho; Takeda, Takehiko; Ukai, Mayu; Kishigami, Yasuyuki; Oguchi, Hidenori
2017-02-01
The normal range of plasma brain natriuretic peptide (BNP) in pregnant women is still unclear. Moreover, pregnant women experience dynamic body weight changes and suffer from anemia, but effects on maternal BNP have not been investigated. This study aimed to reveal the normal plasma BNP range and examine the effects of physiological changes on BNP among pregnant women. Plasma BNP, hemoglobin, plasma creatinine and BMI were measured in 58 non-pregnant control women and in 773 normal pregnant women at late pregnancy, early postpartum and 1-month postpartum. Mean plasma BNP (in pg/mL) was 11.8 (95% confidence interval: 0-27.5) in non-pregnant women, 17.9 (0-44.7, p<0.001) at late pregnancy, 42.5 (0-112.6, p<0.001) early postpartum and 16.1 (0-43.9, p=0.001) 1-month postpartum. Multiple regression analysis revealed that pre-delivery BNP levels were negatively correlated with BMI (p<0.001) and hemoglobin (p=0.002) and positively correlated with creatinine (p<0.001). Post-delivery BNP was positively associated with body weight change during pregnancy (p=0.001) and post-delivery creatinine (p=0.010) but negatively associated with body weight loss at delivery (p<0.001) and post-delivery hemoglobin (p=0.004). Even normal pregnancy affects plasma BNP, particularly in the early postpartum period, indicative of cardiac stress. Plasma BNP levels are affected by BMI, body weight changes, creatinine and hemoglobin levels; therefore, these factors should be considered when analysing cardiac function and the physiological implications of BNP levels in pregnant women. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Thermal emittance from ionization-induced trapping in plasma accelerators
Schroeder, C. B.; Vay, J. -L.; Esarey, E.; ...
2014-10-03
The minimum obtainable transverse emittance (thermal emittance) of electron beams generated and trapped in plasma-based accelerators using laser ionization injection is examined. The initial transverse phase space distribution following ionization and passage through the laser is derived, and expressions for the normalized transverse beam emittance, both along and orthogonal to the laser polarization, are presented. Results are compared to particle-in-cell simulations. Ultralow emittance beams can be generated using laser ionization injection into plasma accelerators, and examples are presented showing normalized emittances on the order of tens of nm.
Measurement of tokamak error fields using plasma response and its applicability to ITER
Strait, Edward J.; Buttery, Richard J.; Casper, T. A.; ...
2014-04-17
The nonlinear response of a low-beta tokamak plasma to non-axisymmetric fields offers an alternative to direct measurement of the non-axisymmetric part of the vacuum magnetic fields, often termed “error fields”. Possible approaches are discussed for determination of error fields and the required current in non-axisymmetric correction coils, with an emphasis on two relatively new methods: measurement of the torque balance on a saturated magnetic island, and measurement of the braking of plasma rotation in the absence of an island. The former is well suited to ohmically heated discharges, while the latter is more appropriate for discharges with a modest amountmore » of neutral beam heating to drive rotation. Both can potentially provide continuous measurements during a discharge, subject to the limitation of a minimum averaging time. The applicability of these methods to ITER is discussed, and an estimate is made of their uncertainties in light of the specifications of ITER’s diagnostic systems. Furthermore, the use of plasma response-based techniques in normal ITER operational scenarios may allow identification of the error field contributions by individual central solenoid coils, but identification of the individual contributions by the outer poloidal field coils or other sources is less likely to be feasible.« less
NASA Astrophysics Data System (ADS)
Peterson, David; Coumou, David; Shannon, Steven
2015-11-01
Time resolved electron density measurements in pulsed RF discharges are shown using a hairpin resonance probe using low cost electronics, on par with normal Langmuir probe boxcar mode operation. Time resolution of 10 microseconds has been demonstrated. A signal generator produces the applied microwave frequency; the reflected waveform is passed through a directional coupler and filtered to remove the RF component. The signal is heterodyned with a frequency mixer and rectified to produce a DC signal read by an oscilloscope. At certain points during the pulse, the plasma density is such that the applied frequency is the same as the resonance frequency of the probe/plasma system, creating reflected signal dips. The applied microwave frequency is shifted in small increments in a frequency boxcar routine to determine the density as a function of time. A dc sheath correction is applied for the grounded probe, producing low cost, high fidelity, and highly reproducible electron density measurements. The measurements are made in both inductively and capacitively coupled systems, the latter driven by multiple frequencies where a subset of these frequencies are pulsed. Measurements are compared to previous published results, time resolved OES, and in-line measurement of plasma impedance. This work is supported by the NSF DOE partnership on plasma science, the NSF GOALI program, and MKS Instruments.
Validation of MHD Models using MST RFP Plasmas
NASA Astrophysics Data System (ADS)
Jacobson, C. M.; Chapman, B. E.; den Hartog, D. J.; McCollam, K. J.; Sarff, J. S.; Sovinec, C. R.
2017-10-01
Rigorous validation of computational models used in fusion energy sciences over a large parameter space and across multiple magnetic configurations can increase confidence in their ability to predict the performance of future devices. MST is a well diagnosed reversed-field pinch (RFP) capable of operation with plasma current ranging from 60 kA to 500 kA. The resulting Lundquist number S, a key parameter in resistive magnetohydrodynamics (MHD), ranges from 4 ×104 to 8 ×106 for standard RFP plasmas and provides substantial overlap with MHD RFP simulations. MST RFP plasmas are simulated using both DEBS, a nonlinear single-fluid visco-resistive MHD code, and NIMROD, a nonlinear extended MHD code, with S ranging from 104 to 105 for single-fluid runs, and the magnetic Prandtl number Pm = 1 . Validation metric comparisons are presented, focusing on how normalized magnetic fluctuations at the edge b scale with S. Preliminary results for the dominant n = 6 mode are b S - 0 . 20 +/- 0 . 02 for single-fluid NIMROD, b S - 0 . 25 +/- 0 . 05 for DEBS, and b S - 0 . 20 +/- 0 . 02 for experimental measurements, however there is a significant discrepancy in mode amplitudes. Preliminary two-fluid NIMROD results are also presented. Work supported by US DOE.
Features of self-organized plasma physics in tokamaks
NASA Astrophysics Data System (ADS)
Razumova, K. A.
2018-01-01
The history of investigations the role of self-organization processes in tokamak plasma confinement is presented. It was experimentally shown that the normalized pressure profile is the same for different tokamaks. Instead of the conventional Fick equation, where the thermal flux is proportional to a pressure gradient, processes in the plasma are well described by the Dyabilanin’s energy balance equation, in which the heat flux is proportional to the difference of normalized gradients for self-consistent and real pressure profiles. The transport coefficient depends on the values of heat flux, which compensates distortion of the pressure profile with external impacts. Radiative cooling of the plasma edge decreases the heat flux and improves the confinement.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zangar, Richard C.; Varnum, Susan M.
A biomarker, method, test kit, and diagnostic system for detecting the presence of lymphoma in a person are disclosed. The lymphoma may be Hodgkin's lymphoma or non-Hodgkin's lymphoma. The person may be a high-risk subject. In one embodiment, a plasma sample from a person is obtained. The level of at least one protein listed in Table S3 in the plasma sample is measured. The level of at least one protein in the plasma sample is compared with the level in a normal or healthy subject. The lymphoma is diagnosed based upon the level of the at least one protein inmore » the plasma sample in comparison to the normal or healthy level.« less
Access to high beta advanced inductive plasmas at low injected torque
NASA Astrophysics Data System (ADS)
Solomon, W. M.; Politzer, P. A.; Buttery, R. J.; Holcomb, C. T.; Ferron, J. R.; Garofalo, A. M.; Grierson, B. A.; Hanson, J. M.; In, Y.; Jackson, G. L.; Kinsey, J. E.; La Haye, R. J.; Lanctot, M. J.; Luce, T. C.; Okabayashi, M.; Petty, C. C.; Turco, F.; Welander, A. S.
2013-09-01
Recent experiments on DIII-D demonstrate that advanced inductive (AI) discharges with high equivalent normalized fusion gain can be accessed and sustained with very low amounts (∼1 N m) of externally injected torque, a level of torque that is anticipated to drive a similar amount of rotation as the beams on ITER, via simple consideration of the scaling of the moment of inertia and confinement time. The AI regime is typically characterized by high confinement, and high βN, allowing the possibility for high performance, high gain operation at reduced plasma current. Discharges achieved βN ∼ 3.1 with H98(y,2) ∼ 1 at q95 ∼ 4, and are sustained for the maximum duration of the counter neutral beams (NBs). In addition, plasmas using zero net NB torque from the startup all the way through to the high βN phase have been created. AI discharges are found to become increasingly susceptible to m/n = 2/1 neoclassical tearing modes as the torque is decreased, which if left unmitigated, generally slow and lock, terminating the high performance phase of the discharge. Access is not notably different whether one ramps the torque down at high βN, or ramps βN up at low torque. The use of electron cyclotron heating (ECH) and current drive proved to be an effective method of avoiding such modes, enabling stable operation at high beta and low torque, a portion of phase space that has otherwise been inaccessible. Thermal confinement is significantly reduced at low rotation, a result that is reproduced using the TGLF transport model. Although it is thought that stiffness is increased in regions of low magnetic shear, in these AI plasmas, the reduced confinement occurs at radii outside the low shear, and in fact, higher temperature gradients can be found in the low shear region at low rotation. Momentum transport is also larger at low rotation, but a significant intrinsic torque is measured that is consistent with a previous scaling considering the role of the turbulent Reynolds stress and thermal ion orbit loss. Although high normalized fusion performance has been achieved in these discharges, more detailed projections suggest that enhancement in the confinement needs to be realized in order to obtain a low current solution consistent with ITER Q = 10 performance, and this remains a future research challenge.
NASA Astrophysics Data System (ADS)
Lazanja, David; Boozer, Allen
2006-10-01
Given the total magnetic field on a toroidal plasma surface, a method for decomposing the field into a part due to internal currents (often the plasma) and a part due to external currents is presented. The method exploits Laplace theory which is valid in the vacuum region between the plasma surface and the chamber walls. The method is developed for the full three dimensional case which is necessary for studying stellarator plasma configurations. A change in the plasma shape is produced by the total normal field perturbation on the plasma surface. This method allows a separation of the total normal field perturbation into a part produced by external currents and a part produced by the plasma response. There are immediate applications to coil design. The computational procedure is based on Merkel's 1986 work on vacuum field computations. Several test cases are presented for toroidal surfaces which verify the method and computational robustness of the code.
A Fusion Nuclear Science Facility for a fast-track path to DEMO
Garofalo, Andrea M.; Abdou, M.; Canik, John M.; ...
2014-10-01
An accelerated fusion energy development program, a “fast-track” approach, requires developing an understanding of fusion nuclear science (FNS) in parallel with research on ITER to study burning plasmas. A Fusion Nuclear Science Facility (FNSF) in parallel with ITER provides the capability to resolve FNS feasibility issues related to power extraction, tritium fuel sustainability, and reliability, and to begin construction of DEMO upon the achievement of Q~10 in ITER. Fusion nuclear components, including the first wall (FW)/blanket, divertor, heating/fueling systems, etc. are complex systems with many inter-related functions and different materials, fluids, and physical interfaces. These in-vessel nuclear components must operatemore » continuously and reliably with: (a) Plasma exposure, surface particle & radiation loads, (b) High energy 2 neutron fluxes and their interactions in materials (e.g. peaked volumetric heating with steep gradients, tritium production, activation, atomic displacements, gas production, etc.), (c) Strong magnetic fields with temporal and spatial variations (electromagnetic coupling to the plasma including off-normal events like disruptions), and (d) a High temperature, high vacuum, chemically active environment. While many of these conditions and effects are being studied with separate and multiple effect experimental test stands and modeling, fusion nuclear conditions cannot be completely simulated outside the fusion environment. This means there are many new multi-physics, multi-scale phenomena and synergistic effects yet to be discovered and accounted for in the understanding, design and operation of fusion as a self-sustaining, energy producing system, and significant experimentation and operational experience in a true fusion environment is an essential requirement. In the following sections we discuss the FNSF objectives, describe the facility requirements and a facility concept and operation approach that can accomplish those objectives, and assess the readiness to construct with respect to several key FNSF issues: materials, steady-state operation, disruptions, power exhaust, and breeding blanket. Finally we present our conclusions.« less
Chronic bile duct hyperplasia is a chronic graft dysfunction following liver transplantation.
Jiang, Jian-Wen; Ren, Zhi-Gang; Cui, Guang-Ying; Zhang, Zhao; Xie, Hai-Yang; Zhou, Lin
2012-03-14
To investigate pathological types and influential factors of chronic graft dysfunction (CGD) following liver transplantation (LT) in rats. The whole experiment was divided into three groups: (1) normal group (n = 12): normal BN rats without any drug or operation; (2) syngeneic transplant group (SGT of BN-BN, n = 12): both donors and recipients were BN rats; and (3) allogeneic transplant group (AGT of LEW-BN, n = 12): Donors were Lewis and recipients were BN rats. In the AGT group, all recipients were subcutaneously injected by Cyclosporin A after LT. Survival time was observed for 1 year. All the dying rats were sampled, biliary tract tissues were performed bacterial culture and liver tissues for histological study. Twenty-one day after LT, 8 rats were selected randomly in each group for sampling. Blood samples from caudal veins were collected for measurements of plasma endotoxin, cytokines and metabonomic analysis, and faeces were analyzed for intestinal microflora. During the surgery of LT, no complications of blood vessels or bile duct happened, and all rats in each group were still alive in the next 2 wk. The long term observation revealed that a total of 8 rats in the SGT and AGT groups died of hepatic graft diseases, 5 rats in which died of chronic bile duct hyperplasia. Compared to the SGT and normal groups, survival ratio of rats significantly decreased in the AGT group (P < 0.01). Moreover, liver necrosis, liver infection, and severe chronic bile duct hyperplasia were observed in the AGT group by H and E stain. On 21 d after LT, compared with the normal group (25.38 ± 7.09 ng/L) and SGT group (33.12 ± 10.26 ng/L), plasma endotoxin in the AGT group was remarkably increased (142.86 ± 30.85 ng/L) (both P < 0.01). Plasma tumor necrosis factor-α and interleukin-6 were also significantly elevated in the AGT group (593.6 ± 171.67 pg/mL, 323.8 ± 68.30 pg/mL) vs the normal (225.5 ± 72.07 pg/mL, 114.6 ± 36.67 pg/mL) and SGT groups (321.3 ± 88.47 pg/mL, 205.2 ± 53.06 pg/mL) (P < 0.01). Furthermore, Bacterial cultures of bile duct tissues revealed that the rats close to death from the SGT and AGT groups were strongly positive, while those from the normal group were negative. The analysis of intestinal microflora was performed. Compared to the normal group (7.98 ± 0.92, 8.90 ± 1.44) and SGT group (8.51 ± 0.46, 9.43 ± 0.69), the numbers of Enterococcus and Enterobacteria in the AGT group (8.76 ± 1.93, 10.18 ± 1.64) were significantly increased (both P < 0.01). Meanwhile, compared to the normal group (9.62 ± 1.60, 9.93 ± 1.10) and SGT group (8.95 ± 0.04, 9.02 ± 1.14), the numbers of Bifidobacterium and Lactobacillus in the AGT group (7.83 ± 0.72, 8.87 ± 0.13) were remarkably reduced (both P < 0.01). In addition, metabonomics analysis showed that metabolic profiles of plasma in rats in the AGT group were severe deviated from the normal and SGT groups. Chronic bile duct hyperplasia is a pathological type of CGD following LT in rats. The mechanism of this kind of CGD is associated with the alterations of inflammation, intestinal barrier function and microflora as well as plasma metabolic profiles.
Ramachandran, Surya; Venugopal, Anila; Kutty, V Raman; A, Vinitha; G, Divya; Chitrasree, V; Mullassari, Ajit; Pratapchandran, N S; Santosh, K R; Pillai, M Radhakrishna; Kartha, C C
2014-02-07
Cyclophilin A, an immunophilin is secreted from human monocytes activated by high glucose. Given its role as an inflammatory mediator of vascular tissue damage associated with inflammation and oxidative stress, we examined plasma levels of cyclophilin A in normal healthy volunteers and patients with type 2 diabetes (DM), with or without coronary artery disease (CAD). Study subjects comprised of 212 patients with DM and CAD,101 patients with diabetes, 122 patients with CAD and 121 normal healthy volunteers. Diabetes was assessed by HbA1c levels while coronary artery disease was established by a positive treadmill test and/or coronary angiography. Plasma cyclophilin A was measured using a cyclophilin A ELISA Kit. Relationship of plasma cyclophilin A levels with blood markers of type 2 diabetes, blood lipid levels and medication for diabetes and coronary artery disease were also explored. Plasma Cyclophilin levels were higher in diabetes patients with or without CAD compared to normal subjects (P < 0.001). Age, fasting blood sugar levels and HbA1C levels were positively associated with increased plasma cyclophilin. Patients using metformin had reduced levels of plasma cyclophilin (p < 0.001).Serum levels of total cholesterol, LDL cholesterol and triglycerides had no significant association with plasma cyclophilin levels. In patients with increased serum CRP levels, plasma cyclophilin A was also elevated (p = 0.016). Prevalence odds for DM, DM + CAD and CAD are higher in those with high cyclophilin values, compared to those with lower values, after adjusting for age and sex, indicating strong association of high cyclophilin values with diabetes and vascular disease. Our study demonstrates that patients with type 2 diabetes have higher circulating levels of cyclophilin A than the normal population. Plasma cyclophilin levels were increased in patients with diabetes and coronary artery disease suggesting a role of this protein in accelerating vascular disease in type 2 diabetes. Considering the evidence that Cyclophilin A is an inflammatory mediator in atherogenesis, the mechanistic role of cyclophilin A in diabetic vascular disease progression deserves detailed investigation.
2014-01-01
Aims/hypothesis Cyclophilin A, an immunophilin is secreted from human monocytes activated by high glucose. Given its role as an inflammatory mediator of vascular tissue damage associated with inflammation and oxidative stress, we examined plasma levels of cyclophilin A in normal healthy volunteers and patients with type 2 diabetes (DM), with or without coronary artery disease (CAD). Methods Study subjects comprised of 212 patients with DM and CAD,101 patients with diabetes, 122 patients with CAD and 121 normal healthy volunteers. Diabetes was assessed by HbA1c levels while coronary artery disease was established by a positive treadmill test and/or coronary angiography. Plasma cyclophilin A was measured using a cyclophilin A ELISA Kit. Relationship of plasma cyclophilin A levels with blood markers of type 2 diabetes, blood lipid levels and medication for diabetes and coronary artery disease were also explored. Results Plasma Cyclophilin levels were higher in diabetes patients with or without CAD compared to normal subjects (P < 0.001). Age, fasting blood sugar levels and HbA1C levels were positively associated with increased plasma cyclophilin. Patients using metformin had reduced levels of plasma cyclophilin (p < 0.001).Serum levels of total cholesterol, LDL cholesterol and triglycerides had no significant association with plasma cyclophilin levels. In patients with increased serum CRP levels, plasma cyclophilin A was also elevated (p = 0.016). Prevalence odds for DM, DM + CAD and CAD are higher in those with high cyclophilin values, compared to those with lower values, after adjusting for age and sex, indicating strong association of high cyclophilin values with diabetes and vascular disease. Conclusions/interpretations Our study demonstrates that patients with type 2 diabetes have higher circulating levels of cyclophilin A than the normal population. Plasma cyclophilin levels were increased in patients with diabetes and coronary artery disease suggesting a role of this protein in accelerating vascular disease in type 2 diabetes. Considering the evidence that Cyclophilin A is an inflammatory mediator in atherogenesis, the mechanistic role of cyclophilin A in diabetic vascular disease progression deserves detailed investigation. PMID:24502618
Recent Progress on Spherical Torus Research
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ono, Masayuki; Kaita, Robert
2014-01-01
The spherical torus or spherical tokamak (ST) is a member of the tokamak family with its aspect ratio (A = R0/a) reduced to A ~ 1.5, well below the normal tokamak operating range of A ≥ 2.5. As the aspect ratio is reduced, the ideal tokamak beta β (radio of plasma to magnetic pressure) stability limit increases rapidly, approximately as β ~ 1/A. The plasma current it can sustain for a given edge safety factor q-95 also increases rapidly. Because of the above, as well as the natural elongation κ, which makes its plasma shape appear spherical, the ST configurationmore » can yield exceptionally high tokamak performance in a compact geometry. Due to its compactness and high performance, the ST configuration has various near term applications, including a compact fusion neutron source with low tritium consumption, in addition to its longer term goal of attractive fusion energy power source. Since the start of the two megaampere class ST facilities in 2000, National Spherical Torus Experiment (NSTX) in the US and Mega Ampere Spherical Tokamak (MAST) in UK, active ST research has been conducted worldwide. More than sixteen ST research facilities operating during this period have achieved remarkable advances in all of fusion science areas, involving fundamental fusion energy science as well as innovation. These results suggest exciting future prospects for ST research both near term and longer term. The present paper reviews the scientific progress made by the worldwide ST research community during this new mega-ampere-ST era.« less
Navarro-González, David; Sánchez-Íñigo, Laura; Pastrana-Delgado, Juan; Fernández-Montero, Alejandro; Martinez, J Alfredo
2016-05-01
We evaluated the potential role of the triglyceride-glucose index (TyG index) as a predictor of diabetes in a White European cohort, and compared it to fasting plasma glucose (FPG) and triglycerides. 4820 patients of the Vascular-Metabolic CUN cohort (VMCUN cohort) were examined and followed up for 8.84years (±4.39). We performed a Cox proportional hazard ratio with repeated-measures analyses to assess the risk of developing type 2 diabetes across quartiles of FPG, triglycerides and the TyG index (ln[fasting triglycerides (mg/dl)×fasting plasma glucose (mg/dl)/2]), and plotted a receiver operating characteristics (ROC) curve for discrimination. There were 332 incident cases of type 2 diabetes involving 43,197.32person-years of follow-up. We observed a progressively increased risk of diabetes in subjects with TyG index levels of 8.31 or more. Among those with normal fasting glucose at baseline, <100mg/dl, subjects with the TyG index in the fourth quartile were 6.87 times more likely to develop diabetes (95% CI, 2.76-16.85; P for trend<0.001), as compared with the bottom quartile. The areas under the ROC curves (95% CI) were 0.75 (0.70-0.81) for TyG index, 0.66 (0.60-0.72) for FPG and 0.71 (0.65-0.77) for TG, in subjects with normal fasting glucose (p=0.017). Our data suggest that the TyG index is useful for the early identification of individuals at risk of type 2 diabetes. The TyG index seems to be a better predictor than FPG or triglycerides of the potential development of type 2 diabetes in normoglycemic patients. Copyright © 2016 Elsevier Inc. All rights reserved.
Polarized Raman spectroscopic characterization of normal and oral cancer blood plasma
NASA Astrophysics Data System (ADS)
Pachaiappan, Rekha; Prakasarao, Aruna; Singaravelu, Ganesan
2017-02-01
In India oral cancer ranks the top due to the habitual usage of tobacco in its various forms and remains the major burden. Hence priority is given for early diagnosis as it is the better solution for cure or to improve the survival rate. For the past three decades, optical spectroscopic techniques have shown its capacity in the discrimination of normal and malignant samples. Many research works have conventional Raman in the effective detection of cancer using the variations in bond vibrations of the molecules. However in addition polarized Raman provides the orientation and symmetry of biomolecules. If so can polarized Raman be the better choice than the conventional Raman in the detection of cancer? The present study aimed to found the answer for the above query. The conventional and polarized Raman spectra were acquired for the same set of blood plasma samples of normal subjects and oral malignant (OSCC) patients. Thus, obtained Raman spectral data were compared using linear discriminant analysis coupled with artificial neural network (LDA-ANN). The depolarization ratio of biomolecules such as antioxidant, amino acid, protein and nucleic acid bases present in blood plasma was proven to be the best attributes in the categorization of the groups. The polarized Raman results were promising in discriminating oral cancer blood plasma from that of normal blood plasma with improved efficiency. The results will be discussed in detail.
Comparison of hypertonic saline versus normal saline on cytokine profile during CABG.
Mazandarani, Mahnaz; Yousefshahi, Fardin; Abdollahi, Mohammad; Hamishehkar, Hadi; Barkhordari, Khosro; Boroomand, Mohammad Ali; Jalali, Arash; Ahmadi, Arezoo; Moharari, Reza Shariat; Bashirzadeh, Mona; Mojtahedzadeh, Mojtaba
2012-10-08
Blood contact with artificial surfaces of the extracorporeal circuit and ischemia-reperfusion injury in CABG with CPB, may lead to a systemic inflammatory response. Hypertonic saline have been recently investigated as a fluid in order to decrease inflammatory response and cytokines generation in patients undergo cardiac operations. Our purpose is to study the prophylactic effect of HS 5% infusion versus NS on serum IL-6 as an inflammatory & IL-10 as an anti-inflammatory biomarker in CABG patients. The present study is a randomized double-blinded clinical trial. 40 patients undergoing CABG were randomized to receive HS 5% or NS before operation. Blood samples were obtained after receiving HS or NS, just before operation, 24 and 48 hours post-operatively. Plasma levels of IL-6 and IL-10 were measured by ELISA. Patients received HS had lower levels of IL-6 and higher level of IL-10 compared with NS group, however these differences were not statistically significant. Results of this study suggest that pre-treatment with small volume hypertonic saline 5% may have beneficial effects on inflammatory response following CABG operation.
Linquette, M; Lefebvre, J; Racadot, A; Cappoen, J P
1975-01-01
The adrenocortical function was studied in 23 patients with hyperthyroidism and compared with a group of 15 normal subjects. Parameters of adrenal function were determined with 1,2(3)H-cortisol. The half-life of cortisol is significantly shortened in hyperthyroidism, as compared to normal subjects (49,5 +/- 6,6 min vs 68,3 +/- 10,5 min) and metabolic clearance rate is increased (418,5 +/- 89,5 L/24 h vs 237,5 +/- 48,5 L/24 h, for normal subjects). The production rate of cortisol, calculated from specific and cumulate activities of THE and THF is increased in hyperthyroidism expressed as mg/24 h or mg/m2/24 h (respectively : 26,7 +/- 7,8 mg/24 h vs 15,7 +/- 3 mg/24 h and 16,9 +/- 4,6 mg/m2/24 h vs 9,5 +/- 1,8 mg/m2/24 h). The mean plasma concentration, calculated as the radio (see article) is not statiscally different in hyperthyroid and normal subjects (6,8 +/- 2,1 microg/100 ml vs 7,3 +/- 1,9 microg/100 ml). 7 patients were reinvestigated after treatment of thyrotoxicosis when they were clinically and biologically in euthyroid state. All the values were normalized, without statistically significant difference from control (T 1/2 = 65,4 +/- 18 min, Metb Cl. Rate : 255 +/- 64,5 L/24 h, production rate : 15,6 +/- 1,8 mg/24 h and 9 +/- 1,4 mg/m2/24 h. mean plasma concentration : 6,8 +/- 2,8 microg/100 ml). Shortened cortisol half life, increased metabolic clearance rate and production rate, and normal mean plasma concentration have been reported in hyperthyroidism (Peterson, Copinschi, Gallagher). These changes, secondary to thyroid hormone excess, are the consequences of increased hepatic catabolism of cortisol. The activity of 11 OH steroid deshydrogenase is increased, as demonstrated by increased ratio (see article) in normal subjects (0,001 less than p less than 0,005). There is a high proportion of 17 kéto metabolites (E, DHE, THE) whose feed-back effect is weak as compared to 17 OH metabolites (F, DHF, THF). The hypothalamo-hypophyso-adrenal system is stimulated to maintain a normal plasma concentration. The fact that the mean plasma concentration is normal despite the increased production rate suggest that changes are rather due to increased catabolism than to central effect of thyroid hormones.
Active control for stabilization of neoclassical tearing modesa)
NASA Astrophysics Data System (ADS)
Humphreys, D. A.; Ferron, J. R.; La Haye, R. J.; Luce, T. C.; Petty, C. C.; Prater, R.; Welander, A. S.
2006-05-01
This work describes active control algorithms used by DIII-D [J. L. Luxon, Nucl. Fusion 42, 614 (2002)] to stabilize and maintain suppression of 3/2 or 2/1 neoclassical tearing modes (NTMs) by application of electron cyclotron current drive (ECCD) at the rational q surface. The DIII-D NTM control system can determine the correct q-surface/ECCD alignment and stabilize existing modes within 100-500ms of activation, or prevent mode growth with preemptive application of ECCD, in both cases enabling stable operation at normalized beta values above 3.5. Because NTMs can limit performance or cause plasma-terminating disruptions in tokamaks, their stabilization is essential to the high performance operation of ITER [R. Aymar et al., ITER Joint Central Team, ITER Home Teams, Nucl. Fusion 41, 1301 (2001)]. The DIII-D NTM control system has demonstrated many elements of an eventual ITER solution, including general algorithms for robust detection of q-surface/ECCD alignment and for real-time maintenance of alignment following the disappearance of the mode. This latter capability, unique to DIII-D, is based on real-time reconstruction of q-surface geometry by a Grad-Shafranov solver using external magnetics and internal motional Stark effect measurements. Alignment is achieved by varying either the plasma major radius (and the rational q surface) or the toroidal field (and the deposition location). The requirement to achieve and maintain q-surface/ECCD alignment with accuracy on the order of 1cm is routinely met by the DIII-D Plasma Control System and these algorithms. We discuss the integrated plasma control design process used for developing these and other general control algorithms, which includes physics-based modeling and testing of the algorithm implementation against simulations of actuator and plasma responses. This systematic design/test method and modeling environment enabled successful mode suppression by the NTM control system upon first-time use in an experimental discharge.
Li, Mei-Yi; Zhang, Yan-Bo; Zuo, Huan; Liu, Li-Li; Niu, Jing-Zhong
2012-02-25
The present study was to investigate the effect of Salvia miltiorrhiza Bunge. f. alba (SMA) pharmacological pretreatment on apoptosis of cultured hippocampal neurons from neonate rats under oxygen-glucose deprivation (OGD). Cultured hippocampal neurons were randomly divided into five groups (n = 6): normal plasma group, low dose SMA plasma (2.5%) group, middle dose SMA plasma (5%) group, high dose SMA plasma (10%) group and control group. The hippocampal neurons were cultured and treated with plasma from adult Wistar rats intragastrically administered with saline or aqueous extract of SMA. The apoptosis of neurons was induced by glucose-free Earle's solution containing 1 mmol/L Na2S2O4 and labeled by MTT and Annexin V/PI double staining. Moreover, protein expressions of Bcl-2 and Bax were detected by immunofluorescence. The results showed that few apoptotic cells were observed in control group, whereas the number of apoptotic cells was greatly increased in normal plasma group and low dose SMA plasma group. Both middle and high dose SMA plasma could protect cultured hippocampal neurons from apoptosis induced by OGD (P < 0.05). The protective effect of high dose SMA plasma was stronger than that of middle one (P < 0.05). Compared to control, normal plasma and low dose SMA plasma groups, middle and high dose SMA plasma groups both showed significantly higher levels of Bcl-2 (P < 0.05 or 0.01), whereas expressions of Bax was opposite. There were no significant differences of Bcl-2 and Bax expressions between middle and high dose SMA plasma groups. Number of Bcl-2- and Bax-positive cells had similar tendency. Bcl-2/Bax (number of positive cells) ratio was higher in high dose SMA plasma group than those of all the other groups (P < 0.05 or 0.01). These results suggest that pharmacological pretreatment of blood plasma containing middle and high dose SMA could raise viability and inhibit apoptosis of OGD-injured hippocampal neurons by up-regulating the expression of Bcl-2 and down-regulating the expression of Bax.
The impact of Roux-en-Y gastric bypass surgery on normal metabolism in a porcine model
Lindqvist, Andreas; Ekelund, Mikael; Garcia-Vaz, Eliana; Ståhlman, Marcus; Pierzynowski, Stefan; Gomez, Maria F.; Rehfeld, Jens F.; Groop, Leif; Hedenbro, Jan
2017-01-01
Background A growing body of literature on Roux-en-Y gastric bypass surgery (RYGB) has generated inconclusive results on the mechanism underlying the beneficial effects on weight loss and glycaemia, partially due to the problems of designing clinical studies with the appropriate controls. Moreover, RYGB is only performed in obese individuals, in whom metabolism is perturbed and not completely understood. Methods In an attempt to isolate the effects of RYGB and its effects on normal metabolism, we investigated the effect of RYGB in lean pigs, using sham-operated pair-fed pigs as controls. Two weeks post-surgery, pigs were subjected to an intravenous glucose tolerance test (IVGTT) and circulating metabolites, hormones and lipids measured. Bile acid composition was profiled after extraction from blood, faeces and the gallbladder. Results A similar weight development in both groups of pigs validated our experimental model. Despite similar changes in fasting insulin, RYGB-pigs had lower fasting glucose levels. During an IVGTT RYGB-pigs had higher insulin and lower glucose levels. VLDL and IDL were lower in RYGB- than in sham-pigs. RYGB-pigs had increased levels of most amino acids, including branched-chain amino acids, but these were more efficiently suppressed by glucose. Levels of bile acids in the gallbladder were higher, whereas plasma and faecal bile acid levels were lower in RYGB- than in sham-pigs. Conclusion In a lean model RYGB caused lower plasma lipid and bile acid levels, which were compensated for by increased plasma amino acids, suggesting a switch from lipid to protein metabolism during fasting in the immediate postoperative period. PMID:28257455
Plasma antibodies to Abeta40 and Abeta42 in patients with Alzheimer's disease and normal controls.
Xu, Wuhua; Kawarabayashi, Takeshi; Matsubara, Etsuro; Deguchi, Kentaro; Murakami, Tetsuro; Harigaya, Yasuo; Ikeda, Masaki; Amari, Masakuni; Kuwano, Ryozo; Abe, Koji; Shoji, Mikio
2008-07-11
Antibodies to amyloid beta protein (Abeta) are present naturally or after Abeta vaccine therapy in human plasma. To clarify their clinical role, we examined plasma samples from 113 patients with Alzheimer's disease (AD) and 205 normal controls using the tissue amyloid plaque immunoreactivity (TAPIR) assay. A high positive rate of TAPIR was revealed in AD (45.1%) and age-matched controls (41.2%), however, no significance was observed. No significant difference was observed in the MMS score or disease duration between TAPIR-positive and negative samples. TAPIR-positive plasma reacted with the Abeta40 monomer and dimer, and the Abeta42 monomer weakly, but not with the Abeta42 dimer. TAPIR was even detected in samples from young normal subjects and young Tg2576 transgenic mice. Although the Abeta40 level and Abeta40/42 ratio increased, and Abeta42 was significantly decreased in plasma from AD groups when compared to controls, no significant correlations were revealed between plasma Abeta levels and TAPIR grading. Thus an immune response to Abeta40 and immune tolerance to Abeta42 occurred naturally in humans without a close relationship to the Abeta burden in the brain. Clarification of the mechanism of the immune response to Abeta42 is necessary for realization of an immunotherapy for AD.
High voltage AC plasma torches with long electric arcs for plasma-chemical applications
NASA Astrophysics Data System (ADS)
Surov, A. V.; Popov, S. D.; Serba, E. O.; Pavlov, A. V.; Nakonechny, Gh V.; Spodobin, V. A.; Nikonov, A. V.; Subbotin, D. I.; Borovskoy, A. M.
2017-04-01
Powerful AC plasma torches are in demand for a number of advanced plasma chemical applications, they can provide high enthalpy of the working gas. IEE RAS specialists have developed a number of models of stationary thermal plasma torches for continuous operation on air with the power from 5 to 500 kW, and on mixture of H2O, CO2 and CH4 up to 150 kW. AC plasma torches were tested on the pilot plasmachemical installations. Powerful AC plasma torch with hollow electrodes and the gas vortex stabilization of arc in cylindrical channels and its operation characteristics are presented. Lifetime of its continuous operation on air is 2000 hours and thermal efficiency is about 92%, the electric arc length between two electrodes of the plasma torch exceeds 2 m.
Progress Toward Steady State Tokamak Operation Exploiting the high bootstrap current fraction regime
NASA Astrophysics Data System (ADS)
Ren, Q.
2015-11-01
Recent DIII-D experiments have advanced the normalized fusion performance of the high bootstrap current fraction tokamak regime toward reactor-relevant steady state operation. The experiments, conducted by a joint team of researchers from the DIII-D and EAST tokamaks, developed a fully noninductive scenario that could be extended on EAST to a demonstration of long pulse steady-state tokamak operation. Fully noninductive plasmas with extremely high values of the poloidal beta, βp >= 4 , have been sustained at βT >= 2 % for long durations with excellent energy confinement quality (H98y,2 >= 1 . 5) and internal transport barriers (ITBs) generated at large minor radius (>= 0 . 6) in all channels (Te, Ti, ne, VTf). Large bootstrap fraction (fBS ~ 80 %) has been obtained with high βp. ITBs have been shown to be compatible with steady state operation. Because of the unusually large ITB radius, normalized pressure is not limited to low βN values by internal ITB-driven modes. βN up to ~4.3 has been obtained by optimizing the plasma-wall distance. The scenario is robust against several variations, including replacing some on-axis with off-axis neutral beam injection (NBI), adding electron cyclotron (EC) heating, and reducing the NBI torque by a factor of 2. This latter observation is particularly promising for extension of the scenario to EAST, where maximum power is obtained with balanced NBI injection, and to a reactor, expected to have low rotation. However, modeling of this regime has provided new challenges to state-of-the-art modeling capabilities: quasilinear models can dramatically underpredict the electron transport, and the Sauter bootstrap current can be insufficient. The analysis shows first-principle NEO is in good agreement with experiments for the bootstrap current calculation and ETG modes with a larger saturated amplitude or EM modes may provide the missing electron transport. Work supported in part by the US DOE under DE-FC02-04ER54698, DE-AC52-07NA27344, DE-AC02-09CH11466, and the NMCFP of China under 2015GB110000 and 2015GB102000.
Native fluorescence characterization of human liver abnormalities
NASA Astrophysics Data System (ADS)
Ganesan, Singaravelu; Madhuri, S.; Aruna, Prakasa R.; Suchitra, S.; Srinivasan, T. G.
1999-05-01
Fluorescence spectroscopy of intrinsic biomolecules has been extensively used in biology and medicine for the past several decades. In the present study, we report the native fluorescence characteristics of blood plasma from normal human subjects and patients with different liver abnormalities such as hepatitis, leptospirosis, jaundice, cirrhosis and liver cell failure. Native fluorescence spectra of blood plasma -- acetone extract were measured at 405 nm excitation. The average spectrum of normal blood plasma has a prominent emission peak around 464 nm whereas in the case of liver diseased subjects, the primary peak is red shifted with respect to normal. In addition, liver diseased cases show distinct secondary emission peak around 615 nm, which may be attributed to the presence of endogenous porphyrins. The red shift of the prominent emission peak with respect to normal is found to be maximum for hepatitis and minimum for cirrhosis whereas the secondary emission peak around 615 nm was found to be more prominent in the case of cirrhosis than the rest. The ratio parameter I465/I615 is found to be statistically significant (p less than 0.001) in discriminating liver abnormalities from normal.
Maes, Michael; Kubera, Marta; Uytterhoeven, Marc; Vrydags, Nicolas; Bosmans, Eugene
2011-04-01
There is evidence that myalgic encephalomyelitis/chronic fatigue syndrome (ME/CFS) is characterized by activation of immune, inflammatory, oxidative and nitrosative stress (IO&NS) pathways. The present study was carried out in order to examine whether ME/CFS is accompanied by increased levels of plasma peroxides and serum oxidized LDL (oxLDL) antibodies, two biomarkers of oxidative stress. Blood was collected from 56 patients with ME/CFS and 37 normal volunteers. Severity of ME/CFS was measured using the Fibromyalgia and Chronic Fatigue Syndrome (FF) Rating Scale. Plasma peroxide concentrations were significantly higher in patients with ME/CFS than in normal controls. There was a trend towards significantly higher serum oxLDL antibodies in ME/CFS than in controls. Both biomarkers contributed significantly in discriminating between patients with ME/CFS and normal controls. Plasma peroxide and serum oxLDL antibody levels were both significantly related to one of the FF symptoms. The results show that ME/CFS is characterized by increased oxidative stress.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Alhenc-Gelas, F.; Weare, J.A.; Johnson, R.L. Jr.
CE was purified from human lung, and antisera were raised in rabbits. Antisera inhibited the activity of the purified enzyme from lung and kidney and the plasma CE of normal persons and sarcoid patients. With antisera at a titer of 1:100,000, a sensitive, direct RIA was developed. CE purified from lung or kidney and CE present in normal and in sarcoid plasma gave parallel logit-log displacement lines, suggesting immunological identity. The level of CE in normal human plasma was 400 +/- 131 ng/ml. In untreated sarcoid patients, the enzyme level and activity increased in parallel. There was a negative correlationmore » (r . -0.81) between enzyme level and diffusing capacity of the lung for CO in sarcoid patients. Synthetic inhibitors such as captopril or MK 421 did not interfere with the RIA, permitting enzyme levels to be monitored in patients undergoing acute inhibitor therapy. During administration of MK 421, CE activity was negligible and plasma levels of CE did not change. In contrast, renin activity increased eightfold during the inhibitor therapy.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Alhenc-Gelas, F.; Weare, J.A.; Johnson, R.L. Jr.
CE (converting enzyme) was purified from human lung, and antisera were raised in rabbits. Antisera inhibited the activity of the purified enzyme from lung and kidney and the plasma CE of normal persons and sarcoid patients. With antisera at a titer of 1:100,000, a sensitive, direct RIA was developed. CE purified from lung or kidney and CE present in normal and in sarcoid plasma gave parallel logit-log displacement lines, suggesting immunological identity. The level of CE in normal human plasma was 400 +/- 131 ng/ml. In untreated sarcoid patients, the enzyme level and activity increased in parallel. There was amore » negative correlation between enzyme level and diffusing capacity of the lung for CO in sarcoid patients. Synthetic inhibitors such as captopril or MK 421 did not interfere with the RIA, permitting enzyme levels to be monitored in patients undergoing acute inhibitor therapy. During administration of MK 421, CE activity was negligible and plasma levels of CE did not change. In contrast, renin activity increased eightfold during the inhibitor therapy.« less
Graham, John B.; Buckwalter, Joseph A.; Hartley, L. J.; Brinkhous, Kenneth M.
1949-01-01
A study was made of the clotting defect and the course of the malady in a group of male dogs with an inherited, sex-linked bleeding disease. The clotting defect is characterized by a prolonged clotting time and a delayed prothrombin utilization, and is corrected by the addition either of thromboplastin or of normal plasma. A plasma protein fraction, fraction I, also corrects the defect. The defect appears to be due to a deficiency of a plasma factor, which normally, in the presence of platelets, makes thromboplastin available in shed blood. The clotting anomaly appears to be identical with that found in human hemophilia. The hemostatic defect is characterized by repeated hemorrhages, usually without obvious relationship to trauma. Hemarthroses occur frequently and may result in permanent joint deformity. The animals usually die early in life from massive hemorrhage. Transfusions with normal blood or plasma correct the clotting defect and readily control the hemorrhagic phenomena. By the use of transfusions, these dogs have been reared to maturity. PMID:18136192
Charest, P M; Roth, J
1985-12-01
Sialic acid residues were localized by electron microscopy in renal glomeruli of normal and puromycin-treated rats with a cytochemical technique that utilized the Limax flavus lectin. In Lowicryl K4M thin sections from normal rats, sialic acid residues were found along the plasma membrane of the various glomerular cell types and in the glomerular basement membrane as well as the mesangial matrix. In NaDodSO4/PAGE, sialic acid residues of normal glomeruli were mainly confined to a 140-kDa protein previously identified as podocalyxin. The distribution of sialic acid residues in the podocyte plasma membrane was found to be remarkably regionalized. Based on the differential labeling intensity, three plasma membrane domains could be defined: the foot process base, the foot process region above the slit diaphragm, and the body of podocytes. Cytochemical and biochemical analysis of glomeruli from puromycin-treated rats showed a loss of sialic acid residues from glomerular sialoglycoconjugates indicating a perturbated glycosylation.
Wang, Yang; Lv, Yong-Bo; Chu, Chao; Wang, Man; Xie, Bing-Qing; Wang, Lan; Yang, Fan; Yan, Ding-Yi; Yang, Rui-Hai; Yang, Jun; Ren, Yong; Yuan, Zu-Yi; Mu, Jian-Jun
2016-01-01
This study aimed to investigate the association of renalase with blood pressure (BP) and brachial-ankle pulse wave velocity (baPWV) in order to better understand the role of renalase in the pathogenesis of hypertension and atherosclerosis. A total of 344 subjects with normal kidney function were recruited from our previously established cohort in Shaanxi Province, China. They were divided into the normotensive (NT) and hypertensive (HT) groups or high baPWV and normal baPWV on the basis of BP levels or baPWV measured with an automatic waveform analyzer. Plasma renalase was determined through an enzyme-linked immunosorbent assay. Plasma renalase did not significantly differ between HT and NT groups (3.71 ± 0.69 µg/mL vs. 3.72 ± 0.73 μg/mL, P = 0.905) and between subjects with and without high baPWV (3.67 ± 0.66 µg/mL vs. 3.73 ± 0.74 µg/mL, P = 0.505). However, baPWV was significantly higher in the HT group than in the NT group (1460.4 ± 236.7 vs. 1240.7 ± 174.5 cm/s, P < 0.001). Plasma renalase was not correlated with BP levels and baPWV in the entire group. Linear and logistic regression analysis revealed that plasma renalase was not significantly associated with hypertension and high baPWV. Plasma renalase may not be associated with BP and baPWV in Chinese subjects with normal renal function. © 2016 The Author(s) Published by S. Karger AG, Basel.
NASA Astrophysics Data System (ADS)
Duan, J.; Lu, X.; He, G.
2017-01-01
In this work, a co-culture system with liver cancer cell line HepG2 and normal cell line L02 is used to investigate the selective effect on cancer and normal cells by plasma activated medium (PAM), which is closer to the real environment where cancer cells develop. Besides, the co-culture system is a better model to study the selective effect than the widely used separate culture systems, where the cancer cell line and normal cell line are cultured independently. By using the co-culture system, it is found that there is an optimum dose of PAM to induce significant cancer cell apoptosis while keeping minimum damage to normal cells.
Effects of water immersion on plasma catecholamines in normal humans
NASA Technical Reports Server (NTRS)
Epstein, M.; Johnson, G.; Denunzio, A. G.
1983-01-01
An investigation was conducted in order to determine whether water immersion to the neck (NI) alters plasma catecholamines in normal humans. Eight normal subjects were studied during a seated control study (C) and during 4 hr of NI, and the levels of norepinephrine (NE) and epinephrine (E) as determined by radioenzymatic assay were measured hourly. Results show that despite the induction of a marked natriuresis and diuresis indicating significant central hypervolemia, NI failed to alter plasma NE or E levels compared with those of either C or the corresponding prestudy 1.5 hr. In addition, the diuresis and natriuresis was found to vary independently of NE. These results indicate that the response of the sympathetic nervous system to acute volume alteration may differ from the reported response to chronic volume expansion.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yin Yunpeng; Sawin, Herbert H.
The surface roughness evolutions of single crystal silicon, thermal silicon dioxide (SiO{sub 2}), and low dielectric constant film coral in argon plasma have been measured by atomic force microscopy as a function of ion bombardment energy, ion impingement angle, and etching time in an inductively coupled plasma beam chamber, in which the plasma chemistry, ion energy, ion flux, and ion incident angle can be adjusted independently. The sputtering yield (or etching rate) scales linearly with the square root of ion energy at normal impingement angle; additionally, the angular dependence of the etching yield of all films in argon plasma followedmore » the typical sputtering yield curve, with a maximum around 60 deg. -70 deg. off-normal angle. All films stayed smooth after etching at normal angle but typically became rougher at grazing angles. In particular, at grazing angles the rms roughness level of all films increased if more material was removed; additionally, the striation structure formed at grazing angles can be either parallel or transverse to the beam impingement direction, which depends on the off-normal angle. More interestingly, the sputtering caused roughness evolution at different off-normal angles can be qualitatively explained by the corresponding angular dependent etching yield curve. In addition, the roughening at grazing angles is a strong function of the type of surface; specifically, coral suffers greater roughening compared to thermal silicon dioxide.« less
Low Plasma Volume in Normotensive Formerly Preeclamptic Women Predisposes to Hypertension.
Scholten, Ralph R; Lotgering, Fred K; Hopman, Maria T; Van Dijk, Arie; Van de Vlugt, Maureen; Janssen, Mirian C H; Spaanderman, Marc E A
2015-11-01
Formerly preeclamptic women are at risk for cardiovascular disease. Low plasma volume may reflect latent hypertension and potentially links preeclampsia with chronic cardiovascular disease. We hypothesized that low plasma volume in normotensive formerly preeclamptic women predisposes to hypertension. We longitudinally studied n=104 formerly preeclamptic women in whom plasma volume was measured 3 to 30 months after the preeclamptic pregnancy. Cardiovascular variables were assessed at 2 points in time (3-30 months postpartum and 2-5 years thereafter). Study population was divided into low plasma volume (≤1373 mL/m(2)) and normal plasma volume (>1373 mL/m(2)). Primary end point was hypertension at the second visit: defined as ≥140 mm Hg systolic or ≥90 mm Hg diastolic. Secondary outcome of this study was change in traditional cardiovascular risk profile between visits. Variables correlating univariately with change in blood pressure between visits were introduced in regression analysis. Eighteen of 104 (17%) formerly preeclamptic women who were normotensive at first visit had hypertension at second evaluation 2 to 5 years later. Hypertension developed more often in women with low plasma volume (10/35 [29%]) than in women with normal plasma volume (8/69 [12%]; odds ratio, 3.2; 95% confidence interval, 1.4-8.6). After adjustments, relationship between plasma volume status and subsequent hypertension persisted (adjusted odds ratio, 3.0; 95% confidence interval, 1.1-8.5). Mean arterial pressure at second visit correlated inverse linearly with plasma volume (r=-0.49; P<0.01). Initially normotensive formerly preeclamptic women have 17% chance to develop hypertension within 5 years. Women with low plasma volume have higher chance to develop hypertension than women with normal plasma volume. Clinically, follow-up of blood pressure seems warranted in women with history of preeclampsia, even when initially normotensive. © 2015 American Heart Association, Inc.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sudhir, Dass; Bandyopadhyay, M., E-mail: mainak@ter-india.org; Chakraborty, A.
2014-01-15
Impedance matching circuit between radio frequency (RF) generator and the plasma load, placed between them, determines the RF power transfer from RF generator to the plasma load. The impedance of plasma load depends on the plasma parameters through skin depth and plasma conductivity or resistivity. Therefore, for long pulse operation of inductively coupled plasmas, particularly for high power (∼100 kW or more) where plasma load condition may vary due to different reasons (e.g., pressure, power, and thermal), online tuning of impedance matching circuit is necessary through feedback. In fusion grade ion source operation, such online methodology through feedback is notmore » present but offline remote tuning by adjusting the matching circuit capacitors and tuning the driving frequency of the RF generator between the ion source operation pulses is envisaged. The present model is an approach for remote impedance tuning methodology for long pulse operation and corresponding online impedance matching algorithm based on RF coil antenna current measurement or coil antenna calorimetric measurement may be useful in this regard.« less
Major results from the first plasma campaign of the Wendelstein 7-X stellarator
Wolf, R. C.; Ali, A.; Alonso, A.; ...
2017-07-27
Here, after completing the main construction phase of Wendelstein 7-X (W7-X) and successfully commissioning the device, first plasma operation started at the end of 2015. Integral commissioning of plasma start-up and operation using electron cyclotron resonance heating (ECRH) and an extensive set of plasma diagnostics have been completed, allowing initial physics studies during the first operational campaign. Both in helium and hydrogen, plasma breakdown was easily achieved. Gaining experience with plasma vessel conditioning, discharge lengths could be extended gradually. Eventually, discharges lasted up to 6 s, reaching an injected energy of 4 MJ, which is twice the limit originally agreedmore » for the limiter configuration employed during the first operational campaign. At power levels of 4 MW central electron densities reached 3 × 10 19 m –3, central electron temperatures reached values of 7 keV and ion temperatures reached just above 2 keV. Important physics studies during this first operational phase include a first assessment of power balance and energy confinement, ECRH power deposition experiments, 2nd harmonic O-mode ECRH using multi-pass absorption, and current drive experiments using electron cyclotron current drive. As in many plasma discharges the electron temperature exceeds the ion temperature significantly, these plasmas are governed by core electron root confinement showing a strong positive electric field in the plasma centre.« less
Major results from the first plasma campaign of the Wendelstein 7-X stellarator
NASA Astrophysics Data System (ADS)
Wolf, R. C.; Ali, A.; Alonso, A.; Baldzuhn, J.; Beidler, C.; Beurskens, M.; Biedermann, C.; Bosch, H.-S.; Bozhenkov, S.; Brakel, R.; Dinklage, A.; Feng, Y.; Fuchert, G.; Geiger, J.; Grulke, O.; Helander, P.; Hirsch, M.; Höfel, U.; Jakubowski, M.; Knauer, J.; Kocsis, G.; König, R.; Kornejew, P.; Krämer-Flecken, A.; Krychowiak, M.; Landreman, M.; Langenberg, A.; Laqua, H. P.; Lazerson, S.; Maaßberg, H.; Marsen, S.; Marushchenko, M.; Moseev, D.; Niemann, H.; Pablant, N.; Pasch, E.; Rahbarnia, K.; Schlisio, G.; Stange, T.; Pedersen, T. Sunn; Svensson, J.; Szepesi, T.; Trimino Mora, H.; Turkin, Y.; Wauters, T.; Weir, G.; Wenzel, U.; Windisch, T.; Wurden, G.; Zhang, D.; Abramovic, I.; Äkäslompolo, S.; Aleynikov, P.; Aleynikova, K.; Alzbutas, R.; Anda, G.; Andreeva, T.; Ascasibar, E.; Assmann, J.; Baek, S.-G.; Banduch, M.; Barbui, T.; Barlak, M.; Baumann, K.; Behr, W.; Benndorf, A.; Bertuch, O.; Biel, W.; Birus, D.; Blackwell, B.; Blanco, E.; Blatzheim, M.; Bluhm, T.; Böckenhoff, D.; Bolgert, P.; Borchardt, M.; Borsuk, V.; Boscary, J.; Böttger, L.-G.; Brand, H.; Brandt, Ch.; Bräuer, T.; Braune, H.; Brezinsek, S.; Brunner, K.-J.; Brünner, B.; Burhenn, R.; Buttenschön, B.; Bykov, V.; Calvo, I.; Cannas, B.; Cappa, A.; Carls, A.; Carraro, L.; Carvalho, B.; Castejon, F.; Charl, A.; Chernyshev, F.; Cianciosa, M.; Citarella, R.; Ciupiński, Ł.; Claps, G.; Cole, M.; Cole, M. J.; Cordella, F.; Cseh, G.; Czarnecka, A.; Czermak, A.; Czerski, K.; Czerwinski, M.; Czymek, G.; da Molin, A.; da Silva, A.; Dammertz, G.; Danielson, J.; de la Pena, A.; Degenkolbe, S.; Denner, P.; Dhard, D. P.; Dostal, M.; Drevlak, M.; Drewelow, P.; Drews, Ph.; Dudek, A.; Dundulis, G.; Durodie, F.; van Eeten, P.; Effenberg, F.; Ehrke, G.; Endler, M.; Ennis, D.; Erckmann, E.; Esteban, H.; Estrada, T.; Fahrenkamp, N.; Feist, J.-H.; Fellinger, J.; Fernandes, H.; Fietz, W. H.; Figacz, W.; Fontdecaba, J.; Ford, O.; Fornal, T.; Frerichs, H.; Freund, A.; Führer, M.; Funaba, T.; Galkowski, A.; Gantenbein, G.; Gao, Y.; García Regaña, J.; Garcia-Munoz, M.; Gates, D.; Gawlik, G.; Geiger, B.; Giannella, V.; Gierse, N.; Gogoleva, A.; Goncalves, B.; Goriaev, A.; Gradic, D.; Grahl, M.; Green, J.; Grosman, A.; Grote, H.; Gruca, M.; Guerard, C.; Haiduk, L.; Han, X.; Harberts, F.; Harris, J. H.; Hartfuß, H.-J.; Hartmann, D.; Hathiramani, D.; Hein, B.; Heinemann, B.; Heitzenroeder, P.; Henneberg, S.; Hennig, C.; Hernandez Sanchez, J.; Hidalgo, C.; Hölbe, H.; Hollfeld, K. P.; Hölting, A.; Höschen, D.; Houry, M.; Howard, J.; Huang, X.; Huber, M.; Huber, V.; Hunger, H.; Ida, K.; Ilkei, T.; Illy, S.; Israeli, B.; Ivanov, A.; Jablonski, S.; Jagielski, J.; Jelonnek, J.; Jenzsch, H.; Junghans, P.; Kacmarczyk, J.; Kaliatka, T.; Kallmeyer, J.-P.; Kamionka, U.; Karalevicius, R.; Kasahara, H.; Kasparek, W.; Kenmochi, N.; Keunecke, M.; Khilchenko, A.; Kinna, D.; Kleiber, R.; Klinger, T.; Knaup, M.; Kobarg, Th.; Köchl, F.; Kolesnichenko, Y.; Könies, A.; Köppen, M.; Koshurinov, J.; Koslowski, R.; Köster, F.; Koziol, R.; Krämer, M.; Krampitz, R.; Kraszewsk, P.; Krawczyk, N.; Kremeyer, T.; Krings, Th.; Krom, J.; Krzesinski, G.; Ksiazek, I.; Kubkowska, M.; Kühner, G.; Kurki-Suonio, T.; Kwak, S.; Lang, R.; Langish, S.; Laqua, H.; Laube, R.; Lechte, C.; Lennartz, M.; Leonhardt, W.; Lewerentz, L.; Liang, Y.; Linsmeier, Ch.; Liu, S.; Lobsien, J.-F.; Loesser, D.; Loizu Cisquella, J.; Lore, J.; Lorenz, A.; Losert, M.; Lubyako, L.; Lücke, A.; Lumsdaine, A.; Lutsenko, V.; Majano-Brown, J.; Marchuk, O.; Mardenfeld, M.; Marek, P.; Massidda, S.; Masuzaki, S.; Maurer, D.; McCarthy, K.; McNeely, P.; Meier, A.; Mellein, D.; Mendelevitch, B.; Mertens, Ph.; Mikkelsen, D.; Mishchenko, O.; Missal, B.; Mittelstaedt, J.; Mizuuchi, T.; Mollen, A.; Moncada, V.; Mönnich, T.; Morizaki, T.; Munk, R.; Murakami, S.; Musielok, F.; Náfrádi, G.; Nagel, M.; Naujoks, D.; Neilson, H.; Neubauer, O.; Neuner, U.; Ngo, T.; Nocentini, R.; Nührenberg, C.; Nührenberg, J.; Obermayer, S.; Offermanns, G.; Ogawa, K.; Ongena, J.; Oosterbeek, J. W.; Orozco, G.; Otte, M.; Pacios Rodriguez, L.; Pan, W.; Panadero, N.; Panadero Alvarez, N.; Panin, A.; Papenfuß, D.; Paqay, S.; Pavone, A.; Pawelec, E.; Pelka, G.; Peng, X.; Perseo, V.; Peterson, B.; Pieper, A.; Pilopp, D.; Pingel, S.; Pisano, F.; Plaum, B.; Plunk, G.; Povilaitis, M.; Preinhaelter, J.; Proll, J.; Puiatti, M.-E.; Sitjes, A. Puig; Purps, F.; Rack, M.; Récsei, S.; Reiman, A.; Reiter, D.; Remppel, F.; Renard, S.; Riedl, R.; Riemann, J.; Rimkevicius, S.; Riße, K.; Rodatos, A.; Röhlinger, H.; Romé, M.; Rong, P.; Roscher, H.-J.; Roth, B.; Rudischhauser, L.; Rummel, K.; Rummel, T.; Runov, A.; Rust, N.; Ryc, L.; Ryosuke, S.; Sakamoto, R.; Samartsev, A.; Sanchez, M.; Sano, F.; Satake, S.; Satheeswaran, G.; Schacht, J.; Schauer, F.; Scherer, T.; Schlaich, A.; Schlüter, K.-H.; Schmitt, J.; Schmitz, H.; Schmitz, O.; Schmuck, S.; Schneider, M.; Schneider, W.; Scholz, M.; Scholz, P.; Schrittwieser, R.; Schröder, M.; Schröder, T.; Schroeder, R.; Schumacher, H.; Schweer, B.; Shanahan, B.; Shikhovtsev, I. V.; Sibilia, M.; Sinha, P.; Sipliä, S.; Skodzik, J.; Slaby, C.; Smith, H.; Spiess, W.; Spong, D. A.; Spring, A.; Stadler, R.; Standley, B.; Stephey, L.; Stoneking, M.; Stridde, U.; Sulek, Z.; Surko, C.; Suzuki, Y.; Szabó, V.; Szabolics, T.; Szökefalvi-Nagy, Z.; Tamura, N.; Terra, A.; Terry, J.; Thomas, J.; Thomsen, H.; Thumm, M.; von Thun, C. P.; Timmermann, D.; Titus, P.; Toi, K.; Travere, J. M.; Traverso, P.; Tretter, J.; Tsuchiya, H.; Tsujimura, T.; Tulipán, S.; Turnyanskiy, M.; Unterberg, B.; Urban, J.; Urbonavicius, E.; Vakulchyk, I.; Valet, S.; van Millingen, B.; Vela, L.; Velasco, J.-L.; Vergote, M.; Vervier, M.; Vianello, N.; Viebke, H.; Vilbrandt, R.; Vorkörper, A.; Wadle, S.; Wagner, F.; Wang, E.; Wang, N.; Warmer, F.; Wegener, L.; Weggen, J.; Wei, Y.; Wendorf, J.; Werner, A.; Wiegel, B.; Wilde, F.; Winkler, E.; Winters, V.; Wolf, S.; Wolowski, J.; Wright, A.; Xanthopoulos, P.; Yamada, H.; Yamada, I.; Yasuhara, R.; Yokoyama, M.; Zajac, J.; Zarnstorff, M.; Zeitler, A.; Zhang, H.; Zhu, J.; Zilker, M.; Zimbal, A.; Zocco, A.; Zoletnik, S.; Zuin, M.
2017-10-01
After completing the main construction phase of Wendelstein 7-X (W7-X) and successfully commissioning the device, first plasma operation started at the end of 2015. Integral commissioning of plasma start-up and operation using electron cyclotron resonance heating (ECRH) and an extensive set of plasma diagnostics have been completed, allowing initial physics studies during the first operational campaign. Both in helium and hydrogen, plasma breakdown was easily achieved. Gaining experience with plasma vessel conditioning, discharge lengths could be extended gradually. Eventually, discharges lasted up to 6 s, reaching an injected energy of 4 MJ, which is twice the limit originally agreed for the limiter configuration employed during the first operational campaign. At power levels of 4 MW central electron densities reached 3 × 1019 m-3, central electron temperatures reached values of 7 keV and ion temperatures reached just above 2 keV. Important physics studies during this first operational phase include a first assessment of power balance and energy confinement, ECRH power deposition experiments, 2nd harmonic O-mode ECRH using multi-pass absorption, and current drive experiments using electron cyclotron current drive. As in many plasma discharges the electron temperature exceeds the ion temperature significantly, these plasmas are governed by core electron root confinement showing a strong positive electric field in the plasma centre.
Major results from the first plasma campaign of the Wendelstein 7-X stellarator
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wolf, R. C.; Ali, A.; Alonso, A.
Here, after completing the main construction phase of Wendelstein 7-X (W7-X) and successfully commissioning the device, first plasma operation started at the end of 2015. Integral commissioning of plasma start-up and operation using electron cyclotron resonance heating (ECRH) and an extensive set of plasma diagnostics have been completed, allowing initial physics studies during the first operational campaign. Both in helium and hydrogen, plasma breakdown was easily achieved. Gaining experience with plasma vessel conditioning, discharge lengths could be extended gradually. Eventually, discharges lasted up to 6 s, reaching an injected energy of 4 MJ, which is twice the limit originally agreedmore » for the limiter configuration employed during the first operational campaign. At power levels of 4 MW central electron densities reached 3 × 10 19 m –3, central electron temperatures reached values of 7 keV and ion temperatures reached just above 2 keV. Important physics studies during this first operational phase include a first assessment of power balance and energy confinement, ECRH power deposition experiments, 2nd harmonic O-mode ECRH using multi-pass absorption, and current drive experiments using electron cyclotron current drive. As in many plasma discharges the electron temperature exceeds the ion temperature significantly, these plasmas are governed by core electron root confinement showing a strong positive electric field in the plasma centre.« less
NASA Astrophysics Data System (ADS)
Shimomura, Y.; Aymar, R.; Chuyanov, V. A.; Huguet, M.; Matsumoto, H.; Mizoguchi, T.; Murakami, Y.; Polevoi, A. R.; Shimada, M.; ITER Joint Central Team; ITER Home Teams
2001-03-01
ITER is planned to be the first fusion experimental reactor in the world operating for research in physics and engineering. The first ten years of operation will be devoted primarily to physics issues at low neutron fluence and the following ten years of operation to engineering testing at higher fluence. ITER can accommodate various plasma configurations and plasma operation modes, such as inductive high Q modes, long pulse hybrid modes and non-inductive steady state modes, with large ranges of plasma current, density, beta and fusion power, and with various heating and current drive methods. This flexibility will provide an advantage for coping with uncertainties in the physics database, in studying burning plasmas, in introducing advanced features and in optimizing the plasma performance for the different programme objectives. Remote sites will be able to participate in the ITER experiment. This concept will provide an advantage not only in operating ITER for 24 hours a day but also in involving the worldwide fusion community and in promoting scientific competition among the ITER Parties.
Xu, Li-li; Shen, Jian-jun; Zhou, Hai-yan
2010-07-20
To investigate the effects of parecoxib sodium preemptive analgesia on perioperative cytokine responses and stress responses and postoperative analgesia in patients undergoing ophthalmology surgery. One hundred ASAI-II patients undergoing ophthalmology surgery were randomly divided into 2 groups of fifty: the parecoxib group received parecoxib 40 mg by muscle injection, the control group received an equal volume of 0.9% normal saline two ml. Venous blood samples were obtained at 10 minutes before parecoxib or 0.9% normal saline was injected (T1), 30 minutes (T2) and 60 minutes (T3) after surgery was initiated, the moment when surgery was finished (T4), 6 hours (T5), 12 hours (T6) and 24 hours (T7) after surgery was finished for determination of the plasma levels of IL-6, IL-8, IL-1RA, TNF and IL-1β. At the same time, the plasma levels of epinephrine, norepinephrine, cortisol and adrenocorticotropic hormone at T1-T6 were measured. VAS scores with patients were recorded at 1, 2, 6, 12, 24 h after surgery. The change of the plasma levels of IL-6, IL-8, IL-1RA, TNF, IL-1β in the two groups:in the parecoxib group the plasma levels of TNF and IL-1β did not decreased significantly as compared with the control group (P > 0.05). The plasma levels of IL-6, IL-8 at T4-T6 decreased significantly as compared with the control group (P < 0.01). The plasma levels of IL-1RA at T3-T6 decreased significantly as compared with the control group (P < 0.01). The change of the plasma levels of epinephrine, norepinephrine, cortisol and adrenocorticotropic hormone in the two groups:in the parecoxib group the plasma levels of epinephrine, norepinephrine at T2, T3 decreased significantly as compared with the control group (P < 0.01). In the parecoxib group the plasma levels of cortisol at T2-T4 decreased significantly as compared with the control group (P < 0.01). In the parecoxib group the plasma levels of adrenocorticotropic hormone at T2-T5 decreased significantly as compared with the control group (P < 0.01). Postoperation VAS scores:VAS scores of the parecoxib group were less than that of the control group (P < 0.05). Preoperatively-administered parecoxib during ophthalmology surgery can produce better analgesia effect, reduce the production of cytokines, decrease central nervous system sensitization so as to improve the quality of postoperative pain relief. At the same time, it can reduce perioperative stress hormone release so as to have a positive effect on post operative recovery.
USDA-ARS?s Scientific Manuscript database
Using linear regression models, we studied the main and two-way interaction effects of the predictor variables gender, age, BMI, and 64 folate/vitamin B-12/homocysteine/lipid/cholesterol-related single nucleotide polymorphisms (SNP) on log-transformed plasma homocysteine normalized by red blood cell...
Benjamin, N; Robinson, B F; Graham, J G; Wilson, R B
1990-06-01
The cholesterol:phospholipid ratio was measured in platelet plasma membrane, red blood cell (RBC) membranes, low density lipoprotein (LDL) and whole plasma in patients with primary hypertension and in matched normal controls. The cholesterol:phospholipid ratio was raised in the platelet membrane from hypertensive patients compared with that from normal controls (0.65 +/- 0.03 vs 0.53 +/- 0.02: mean +/- SEM; P less than 0.01). The ratio observed in RBC membranes, LDL and whole blood was similar in the two groups. If this abnormality in the lipid composition of platelet plasma membrane is present in other cells it could account for some of the changes in cell membrane function that have been described in hypertension.
Ideal MHD Stability Prediction and Required Power for EAST Advanced Scenario
NASA Astrophysics Data System (ADS)
Chen, Junjie; Li, Guoqiang; Qian, Jinping; Liu, Zixi
2012-11-01
The Experimental Advanced Superconducting Tokamak (EAST) is the first fully superconducting tokamak with a D-shaped cross-sectional plasma presently in operation. The ideal magnetohydrodynamic (MHD) stability and required power for the EAST advanced tokamak (AT) scenario with negative central shear and double transport barrier (DTB) are investigated. With the equilibrium code TOQ and stability code GATO, the ideal MHD stability is analyzed. It is shown that a moderate ratio of edge transport barriers' (ETB) height to internal transport barriers' (ITBs) height is beneficial to ideal MHD stability. The normalized beta βN limit is about 2.20 (without wall) and 3.70 (with ideal wall). With the scaling law of energy confinement time, the required heating power for EAST AT scenario is calculated. The total heating power Pt increases as the toroidal magnetic field BT or the normalized beta βN is increased.
Ramdane, Said; Daoudi-Gueddah, Doria
2011-08-01
We examined retrospectively the concurrent relationships between fasting plasma total cholesterol, triglycerides, and glucose levels, and Alzheimer's disease (AD), in a clinical setting-based study. Total cholesterol level was higher in patients with AD compared to elderly controls; triglycerides or glucose levels did not significantly differ between the 2 groups. Respective plotted trajectories of change in cholesterol level across age were fairly parallel. No significant difference in total cholesterol levels was recorded between patients with AD classified by the Clinical Dementia Rating (CDR) score subgroups. These results suggest that patients with AD have relative mild total hypercholesterolemia, normal triglyceridemia, and normal fasting plasma glucose level. Mild total hypercholesterolemia seems to be permanent across age, and across dementia severity staging, and fairly parallels the trajectory of age-related change in total cholesterolemia of healthy controls. We speculate that these biochemical parameters pattern may be present long before-a decade at least-the symptomatic onset of the disease.
NASA Astrophysics Data System (ADS)
Sakata, Kenichi
Aplasma-interface is considered the most mysterious part of an inductively coupled plasma mass spectrometer system in terms of understanding its operational mechanism. After a brief explanation of the basic structure of the inductively coupled plasma mass spectrometer and how it works, the plasma-interface is discussed in regard to its complex operation and approaches to investigating its behavior. In particular, the position and shape of the plasma boundary seem to be important to understand the instrument's sensitivity.
NASA Astrophysics Data System (ADS)
Zhang, Yue; Lynn, Alan; Gilmore, Mark; Hsu, Scott; University of New Mexico Collaboration; Los Alamos National Laboratory Collaboration
2013-10-01
A compact coaxial plasma gun is employed for experimental studies of plasma relaxation in a low density background plasma. Experiments are being conducted in the linear HelCat device at UNM. These studies will advance the knowledge of basic plasma physics in the areas of magnetic relaxation and space and astrophysical plasmas, including the evolution of active galactic jets/radio lobes within the intergalactic medium. The gun is powered by a 120pF ignitron-switched capacitor bank which is operated in a range of 5-10 kV and ~100 kA. Multiple diagnostics are employed to investigate plasma relaxation process. Magnetized Argon plasma bubbles with velocities ~1.2Cs and densities ~1020 m-3 have been achieved. Different distinct regimes of operation with qualitatively different dynamics are identified by fast CCD camera images, with the parameter determining the operation regime. Additionally, a B-dot probe array is employed to measure the spatial toroidal and poloidal magnetic flux evolution to identify detached plasma bubble configurations. Experimental data and analysis will be presented.
Nyberg, M; Mortensen, S P; Hellsten, Y
2013-03-01
Endothelin-1 has potent constrictor and proliferative activity in vascular smooth muscle, and essential hypertension and aging are associated with increased endothelin-1-mediated vasoconstrictor tone. The aim of this study was to investigate the effect of physical activity, hypertension and age on endothelin-1 levels in plasma and skeletal muscle and endothelin receptors in skeletal muscle in human subjects. In study 1, normotensive (46 ± 1 years, n = 11) and hypertensive (47 ± 1 years, n = 10) subjects were studied before and after 8 weeks of aerobic exercise training. In study 2, young (23 ± 1 years, n = 8), older lifelong sedentary (66 ± 2 years, n = 8) and older lifelong endurance-trained (62 ± 2 years, n = 8) subjects were studied in a cross-sectional design. Skeletal muscle and plasma endothelin-1 levels were increased with age and plasma endothelin-1 levels were higher in hypertensive than normotensive individuals. Eight weeks of exercise training normalized plasma endothelin-1 levels in the hypertensive subjects and increased the protein expression of the ET(A) receptor in skeletal muscle of normotensive subjects. Similarly, individuals that had performed lifelong physical activity had similar plasma and muscle endothelin-1 levels as the young controls and had higher ET(A) receptor levels. Our findings suggest that aerobic exercise training opposes the age-related increase in skeletal muscle and plasma endothelin-1 levels and normalizes plasma endothelin-1 levels in individuals with essential hypertension. This effect may explain some of the beneficial effects of training on the cardiovascular system in older and hypertensive subjects. © 2012 The Authors Acta Physiologica © 2012 Scandinavian Physiological Society.
Onset of normal and inverse homoclinic bifurcation in a double plasma system near a plasma fireball
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mitra, Vramori; Sarma, Bornali; Sarma, Arun
Plasma fireballs are generated due to a localized discharge and appear as a luminous glow with a sharp boundary, which suggests the presence of a localized electric field such as electrical sheath or double layer structure. The present work reports the observation of normal and inverse homoclinic bifurcation phenomena in plasma oscillations that are excited in the presence of fireball in a double plasma device. The controlling parameters for these observations are the ratio of target to source chamber (n{sub T}/n{sub S}) densities and applied electrode voltage. Homoclinic bifurcation is noticed in the plasma potential fluctuations as the system evolvesmore » from narrow to long time period oscillations and vice versa with the change of control parameter. The dynamical transition in plasma fireball is demonstrated by spectral analysis, recurrence quantification analysis (RQA), and statistical measures, viz., skewness and kurtosis. The increasing trend of normalized variance reflects that enhancing n{sub T}/n{sub S} induces irregularity in plasma dynamics. The exponential growth of the time period is strongly indicative of homoclinic bifurcation in the system. The gradual decrease of skewness and increase of kurtosis with the increase of n{sub T}/n{sub S} also reflect growing complexity in the system. The visual change of recurrence plot and gradual enhancement of RQA variables DET, L{sub max}, and ENT reflects the bifurcation behavior in the dynamics. The combination of RQA and spectral analysis is a clear evidence that homoclinic bifurcation occurs due to the presence of plasma fireball with different density ratios. However, inverse bifurcation takes place due to the change of fireball voltage. Some of the features observed in the experiment are consistent with a model that describes the dynamics of ionization instabilities.« less
Note: Repetitive operation of the capacitor bank of the low-voltage miniature plasma focus at 50 Hz.
Shukla, Rohit; Shyam, Anurag
2013-10-01
We have already reported the low-voltage operation of a plasma focus describing the operation of plasma focus at 4.2 kV which proposes possibility of making a repetitive system using compact driving source. Another recent article describes that the same capacitor-bank can drive the plasma focus for a measured ~5 × 10(4) neutrons per shot at 5 kV and 59 kA current. In the present work, repetitive operation of the capacitor-bank of plasma focus is done and that too is being reported at a very high repetition rate of 50 Hz using very simple scheme of charging and triggering the bank. The bank is continuously discharged to burst duration of 20 s in this configuration admeasuring a thousand shots.
Exposure to triaryl phosphates: metabolism and biomarkers of exposure.
Furlong, Clement E
2011-01-01
The leakage of tricresyl phosphate-containing engine lubricants into aircraft cabin air, either from worn or defective engine seals or under normal operating conditions, is a serious concern for both the health and safety of the cabin occupants, since the oil contains one to five percent tricresyl phosphate (TCP) esters, known neurotoxins. The exposure of pilots is a particular concern since their impairment can affect their safe operation of the aircraft. Mass spectrometric (MS)-based protocols for documenting exposures of individuals are described that entail a rapid purification of the TCP-modified plasma enzyme butyrylcholinesterase (BChE). Following protease digestion of BChE, the modified active site peptide is characterized by MS analysis. Approaches for identifying safer engine oil additives are also described. Some general comments regarding the necessity of improving the quality and safety of the cabin air supply are presented.
Oehlschläger, Sven; Fuessel, Susanne; Meye, Axel; Herrmann, Jana; Froehner, Michael; Albrecht, Steffen; Wirth, Manfred P
2009-03-01
To examine the cellular, plasma, and urinary oxalate and erythrocyte oxalate flux in patients with calcium oxalate monohydrate (COM) stone formation vs normal controls. Pathologic oxalate clearance in humans is mostly integrated in calcium oxalate stone formation. An underlying cause of deficient oxalate clearance could be defective transmembrane oxalate transport, which, in many tissues, is regulated by an anion exchanger (SLC26). We studied 2 groups: 40 normal controls and 41 patients with COM stone formation. Red blood cells were divided for cellular oxalate measurement and for resuspension in a buffered solution (pH 7.40); 0.1 mmol/L oxalate was added. The supernatant was measured for oxalate immediately and 1 hour after incubation. The plasma and urinary oxalate were analyzed in parallel. The mean cellular oxalate concentrations were significantly greater in the normal controls (5.25 +/- 0.47 micromol/L) than in those with COM stone formation (2.36 +/- 0.28 micromol/L; P < .01). The mean urinary oxalate concentrations were significantly greater in those with COM stone formation (0.31 +/- 0.02 mmol/L) than in the controls (0.24 +/- 0.02 mmol/L; P < .01). The cellular oxalate concentrations correlated significantly with the plasma (r = 0.49-0.63; P < .01) and urinary oxalate (r = -0.29-0.41; P < .03) concentrations in both groups. The plasma oxalate concentrations correlated significantly with the urinary oxalate concentrations (r = -0.30; P < .03) in the controls and with the erythrocyte oxalate flux (r = 0.25; P < .05) in those with COM stone formation. Our data implicate the presence of a cellular oxalate buffer to stabilize plasma and urinary oxalate concentrations in normal controls.
Ferrandi, Peter J; Fico, Brandon G; Whitehurst, Michael; Zourdos, Michael C; Bao, Fanchen; Dodge, Katelyn M; Rodriguez, Alexandra L; Pena, Gabriel; Huang, Chun-Jung
2018-06-01
Obesity is associated with lipid aggregation in adipocytes and macrophage infiltration, leading to increased oxidative stress and inflammation. Increased cell-free DNA (cfDNA) concentrations have been observed in clinical conditions of systemic inflammation. While the beneficial effects of regular physical activity on the release of circulating cfDNA still remain unknown, acute intense exercise has been shown to increase inflammatory cytokines and cfDNA concentrations in normal-weight individuals. Therefore, the primary purpose of this study was to examine the effect of acute high-intensity interval Exercise (HIIE) on plasma cfDNA and interleukin-6 (IL-6) responses in obese and normal-weight subjects. Fourteen male subjects (7 obese and 7 normal-weight) participated in an acute HIIE protocol (30 min, 4x4min @ 80% - 90% of VO 2max ) on a treadmill. Between HIIE intervals, subjects performed 3 min of active recovery at 50-60% VO 2max . Blood samples were collected prior to, immediately following exercise, and one hour into recovery for measurements of plasma cfDNA and IL-6. Our results demonstrated a significant elevation in plasma cfDNA immediately following acute HIIE in both obese and normal-weight subjects. A comparable elevation in the concentration of plasma IL-6 was also found between two groups in response to acute HIIE. Furthermore, the level of plasma cfDNA was not correlated with IL-6 either at baseline or in response to acute HIIE. These findings may support the utilization of HIIE as a time-efficient exercise protocol to understand the obesity-associated cfDNA and inflammatory responses. Published by Elsevier Inc.
Yang, Ding-Bo; Yu, Wen-Hua; Dong, Xiao-Qiao; Du, Quan; Shen, Yong-Feng; Zhang, Zu-Yong; Zhu, Qiang; Che, Zhi-Hao; Liu, Qun-Jie; Wang, Hao; Jiang, Li; Du, Yuan-Feng
2014-08-01
Higher plasma copeptin levels correlate with poor clinical outcomes after traumatic brain injury. Nevertheless, their links with acute traumatic coagulopathy and progressive hemorrhagic injury are unknown. Therefore, we aimed to investigate the relationship between plasma copeptin levels, acute traumatic coagulopathy and progressive hemorrhagic injury in patients with severe traumatic brain injury. We prospectively studied 100 consecutive patients presenting within 6h from head trauma. Progressive hemorrhagic injury was present when the follow-up computerized tomography scan reported any increase in size or number of the hemorrhagic lesion, including newly developed ones. Acute traumatic coagulopathy was defined as an activated partial thromboplastic time greater than 40s and/or international normalized ratio greater than 1.2 and/or a platelet count less than 120×10(9)/L. We measured plasma copeptin levels on admission using an enzyme-linked immunosorbent assay in a blinded fashion. In multivariate logistic regression analysis, plasma copeptin level emerged as an independent predictor of progressive hemorrhagic injury and acute traumatic coagulopathy. Using receiver operating characteristic curves, we calculated areas under the curve for progressive hemorrhagic injury and acute traumatic coagulopathy. The predictive performance of copeptin was similar to that of Glasgow Coma Scale score. However, copeptin did not obviously improve the predictive value of Glasgow Coma Scale score. Thus, copeptin may help in the prediction of progressive hemorrhagic injury and acute traumatic coagulopathy after traumatic brain injury. Copyright © 2014 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nad, Shreya; Department of Physics and Astronomy, Michigan State University, East Lansing, Michigan 48824; Gu, Yajun
2015-07-15
The microwave coupling efficiency of the 2.45 GHz, microwave plasma assisted diamond synthesis process is investigated by experimentally measuring the performance of a specific single mode excited, internally tuned microwave plasma reactor. Plasma reactor coupling efficiencies (η) > 90% are achieved over the entire 100–260 Torr pressure range and 1.5–2.4 kW input power diamond synthesis regime. When operating at a specific experimental operating condition, small additional internal tuning adjustments can be made to achieve η > 98%. When the plasma reactor has low empty cavity losses, i.e., the empty cavity quality factor is >1500, then overall microwave discharge coupling efficienciesmore » (η{sub coup}) of >94% can be achieved. A large, safe, and efficient experimental operating regime is identified. Both substrate hot spots and the formation of microwave plasmoids are eliminated when operating within this regime. This investigation suggests that both the reactor design and the reactor process operation must be considered when attempting to lower diamond synthesis electrical energy costs while still enabling a very versatile and flexible operation performance.« less
Operating Characteristics in DIII-D ELM-Suppressed RMP H-modes with ITER Similar Shapes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Evans, T E; Fenstermacher, M E; Jakubowski, M
2008-10-13
Fast energy transients, incident on the DIII-D divertors due to Type-I edge localized modes (ELMs), are eliminated using small dc currents in a simple set of non-axisymmetric coils that produce edge resonant magnetic perturbations (RMP). In ITER similar shaped (ISS) plasmas, with electron pedestal collisionalities matched to those expected in ITER a sharp resonant window in the safety factor at the 95 percent normalized poloidal flux surface is observed for ELM suppression at q{sub 95}=3.57 with a minimum width {delta}q{sub 95} of {+-}0.05. The size of this resonant window has been increased by a factor of 4 in ISS plasmasmore » by increasing the magnitude of the current in an n=3 coil set along with the current in a separate n=1 coil set. The resonant ELM-suppression window is highly reproducible for a given plasma shape, coil configuration and coil current but can vary with other operating conditions such as {beta}{sub N}. Isolated resonant windows have also been found at other q95 values when using different RMP coil configurations. For example, when the I-coil is operated in an n=3 up-down asymmetric configuration rather than an up-down symmetric configuration a resonant window is found near q{sub 95}=7.4. A Fourier analysis of the applied vacuum magnetic field demonstrates a statistical correlation between the Chirikov island overlap parameter and ELM suppression. These results have been used as a guide for RMP coil design studies in various ITER operating scenarios.« less
Versmold, H T; Linderkamp, C; Döhlemann, C; Riegel, K P
1976-06-01
In 48 individuals (age 1 day to 13 years) with congenital heart disease, blood oxygen transport function was studied in order to evaluate adaptive changes in shunt hypoxemia and to investigate the in vivo regulation of erythrocyte 2, 3-diphosphoglycerate concentration (RBC 2, 3-DPG) in the presence of fetal hemoglobin (HbF). Arterial pO2 and oxygen content, oxygen capacity, acid base status, oxygen affinity, HbF fraction, plasma pH, red cell pH, and RBC 2, 3-DPG were determined. During the first 50 days of life values of standard P50 (stdP50) (37, pH 7.4), actual in vivo P50 (actP50), RBC 2, 3-DPG, O2 capacity, arterial plasma pH, and red cell pH were scattered around the normal range, although tending to low values for stdP50 and arterial plasma pH and to high values for O2 capacity. After the third month, stdP50 actP50, RBC 2, 3-DPG, O2 capacity, and red cell pH were found to be elevated. Plasma pH and actP50 were scattered around the normal range (Figs. 1 and 2). Intraerythrocytic pH in hypoxemic infants was increased compared with normal children when related to plasma pH (Fig. 3). A close to normal intraerythrocytic pH was therefore found in the hypoxemic infants with low plasma pH, and an increased intraerythrocytic pH in the hypoxemic children with normal plasma pH (Fig. 1). A significant negative correlation exists between erythrocyte H+ ion and 2, 3-DPG concentration (Fig. 5); regression constants derived from data at high (mean 47%) and low (mean 9%) fractions of HbF are not significantly different (Regression Equations 8 and 11 in Table 1). Thus, the known difference in 2, 3-DPG binding to fetal or adult deoxyhemoglobin does not measurably influence the erythrocyte 2, 3-DPG concentration, indicating that in vivo the 2, 3-DPG synthesis in hypoxia is virtually regulated by the erythrocyte pH, which in turn is determined by plasma pH and the oxygenation state of hemoglobin.
Samuels, Mary; DiStefano, Joseph J.
2008-01-01
Background We upgraded our recent feedback control system (FBCS) simulation model of human thyroid hormone (TH) regulation to include explicit representation of hypothalamic and pituitary dynamics, and updated TH distribution and elimination (D&E) parameters. This new model greatly expands the range of clinical and basic science scenarios explorable by computer simulation. Methods We quantified the model from pharmacokinetic (PK) and physiological human data and validated it comparatively against several independent clinical data sets. We then explored three contemporary clinical issues with the new model: combined triiodothyronine (T3)/thyroxine (T4) versus T4-only treatment, parenteral levothyroxine (L-T4) administration, and central hypothyroidism. Results Combined T3/T4 therapy—In thyroidectomized patients, the L-T4–only replacement doses needed to normalize plasma T3 or average tissue T3 were 145 μg L-T4/day or 165 μgL-T4/day, respectively. The combined T4 + T3 dosing needed to normalize both plasma and tissue T3 levels was 105 μg L-T4 + 9 μgT3 per day. For all three regimens, simulated mean steady-state plasma thyroid-stimulating hormone (TSH), T3, and T4 was within normal ranges (TSH: 0.5–5 mU/L; T4: 5–12 μg/dL; T3: 0.8–1.9 ng/mL). Parenteral T4 administration—800 μg weekly or 400 μg twice weekly normalized average tissue T3 levels both for subcutaneous (SC) and intramuscular (IM) routes of administration. TSH, T3, and T4 levels were maintained within normal ranges for all four of these dosing schemes (1× vs. 2× weekly, SC vs. IM). Central hypothyroidism—We simulated steady-state plasma T3,T4, and TSH concentrations in response to varying degrees of central hypothyroidism, reducing TSH secretion from 50% down to 0.1% of normal. Surprisingly, TSH, T3, and T4 plasma concentrations remained within normal ranges for TSH secretion as low as 25% of normal. Conclusions Combined T3/T4 treatment—Simulated standard L-T4–only therapy was sufficient to renormalize average tissue T3 levels and maintain normal TSH, T3, and T4 plasma levels, supporting adequacy of standard L-T4–only treatment. Parenteral T4 administration—TSH, T3, and T4 levels were maintained within normal ranges for all four of these dosing schemes (1× vs. 2× weekly, SC vs. IM), supporting these therapeutic alternatives for patients with compromised L-T4 gut absorption. Central hypothyroidism—These results highlight how highly nonlinear feedback in the hypothalamic-pituitary-thyroid axis acts to maintain normal hormone levels, even with severely reduced TSH secretion. PMID:18844475
Transport and metabolism of sarcosine in hypersarcosinemic and normal phenotypes
Glorieux, Francis H.; Scriver, Charles R.; Delvin, Edgard; Mohyuddin, Fazl
1971-01-01
An adolescent male proband with hypersarcosinemia was discovered incidentally in a French-Canadian family; no specific disease was associated with the trait. The hypersarcosinemia is not diminished by dietary folic acid even in pharmacologic doses (30 mg/day). The normal absence of sarcosine dehydrogenase in cultured human skin fibroblasts and in leukocytes was confirmed, thus eliminating these tissues as useful sources for further investigation of mutant sarcosinemic phenotypes and genotypes. The response in plasma of sarcosine and glycine, after sarcosine loading, distinguished the normal subject from the subjects who were presumably homozygous and heterozygous for the hypersarcosinemia allele. Sarcosine clearance from plasma was delayed greatly (t½, 6.1 hr) in the presumed homozygote and slightly (t½, 2.2 hr) in the presumed heterozygote, while plasma glycine remained constant in the former and rose in the latter. Normal subjects clear sarcosine from plasma rapidly (t½, 1.6 hr) while their plasma glycine trend is downward. The phenotypic responses suggest that hypersarcosinemia is an autosomal recessive trait in this pedigree. Renal tubular transport of sarcosine was normal in the proband even though he presumably lacked the sarcosine oxidation which should normally occur in kidney. Sarcosine catabolism is thus not important for its own renal uptake. Sarcosine interacts with proline and glycine during its absorption in vivo. Studies in vitro in rat kidney showed that sarcosine transport is mediated, saturable, and energy dependent. Sarcosine has no apparent transport system of its own; it uses the low Km transport systems for L-proline and glycine to a minor extent and a high Km system shared by these substances for the major uptake at concentrations encountered in hypersarcosinemia. Intracellular sarcosine at high concentration will exchange with glycine on one of these systems, which may explain a paradoxical improvement in renal transport of glycine after sarcosine loading in the hypersarcosinemic proband. PMID:5096515
Hesse, B; Ring-Larsen, H; Nielsen, I; Christensen, N J
1978-04-01
Plasma renin activity (PRA), plasma noradrenaline concentration, heart rate, blood pressure, and clearances of para-aminohippurate and inulin were measured in twelve normal subjects (clearances in only three subjects) before and after 40 min of 60 degrees upright tilting. The tilting experiments were repeated after inflation of an anti-gravity suit to 60 mmHg on the lower extremities. Inflation of the anti-gravity suit caused an abolition of the postural PRA increase, a marked reduction of the postural increases in plasma noradrenaline and heart rate, and elimination of the decreases in pulse pressure, inulin and para-aminohippurate clearances and sodium excretion. The results suggest a decisive role of the sympathetic nervous system for postural renin increase, probably mainly activated by stretch receptors in the low-pressure cardiopulmoanry area.
Keyhole and weld shapes for plasma arc welding under normal and zero gravity
NASA Technical Reports Server (NTRS)
Keanini, R. G.; Rubinsky, B.
1990-01-01
A first order study of the interfacial (keyhole) shape between a penetrating argon plasma arc jet and a stationary liquid metal weld pool is presented. The interface is determined using the Young-Laplace equation by assuming that the plasma jet behaves as a one-dimensional ideal gas flow and by neglecting flow within the weld pool. The solution for the keyhole shape allows an approximate determination of the liquid-solid metal phase boundary location based on the assumption that the liquid melt is a stagnant thermal boundary layer. Parametric studies examine the effect of plasma mass flow rate, initial plasma enthalpy, liquid metal surface tension, and jet shear on weldment shape under both normal and zero gravity. Among the more important findings of this study is that keyhole and weld geometries are minimally affected by gravity, suggesting that data gathered under gravity can be used in planning in-space welding.
Hemodynamics, renal function, plasma renin, and aldosterone in man after 5 to 14 days of bedrest
NASA Technical Reports Server (NTRS)
Melada, G. A.; Goldman, R. H.; Luetscher, J. A.; Zager, P. G.
1975-01-01
Continuous bedrest for 5 to 14 days had no significant effect on resting heart rate, blood pressure, or cardiac output in six normal men. Head-up tilt induced greater tachycardia in 5 of 6 patients after bed rest than in the control period. Propranolol diminished both tachycardia and the incidence of hypotension and faintness in upright posture. Plasma volume fell, extracellular fluid volume increased, and plasma renin activity was significantly elevated following bedrest. Unusually large increases in plasma renin followed head-up tilt or administration of isoproterenol during bedrest and after resuming normal activity. During bedrest, plasma aldosterone was often increased in the early morning. It is concluded that after bedrest, upright posture evokes strong beta-adrenergic activity as well as exaggerated metabolic and circulatory responses which can be reduced or abolished by the beta-adrenergic blocker, propranolol.
Hormonal disturbances in visceral leishmaniasis (kala-azar).
Verde, Frederico Araujo Lima; Verde, Francisco Agenor Araujo Lima; Neto, Augusto Saboia; Almeida, Paulo César; Verde, Emir Mendonça Lima
2011-05-01
This study presents a cross-sectional analysis of the hormonal alterations of patients with visceral leishmaniasis. The diagnosis was established by the bone marrow aspiration and polymerase chain reaction test. Primary adrenal insufficiency was observed in 45.8% of patients; low aldosterone/renin plasma ratio in 69.4%; low daily urinary aldosterone excretion in 61.1%; and low transtubular potassium gradient in 68.0%. All patients had normal plasma antidiuretic hormone (ADH) concentrations, hyponatremia, and high urinary osmolality. Plasma parathyroid hormone was low in 63%; hypomagnesemia was present in 46.4%, and increased Mg(++)(EF) in 100%. Primary thyroid insufficiency was observed in 24.6%, and secondary thyroid insufficiency in 14.1%. Normal follicle-stimulating hormone plasma levels were present in 81.4%; high luteinizing hormone and low testosterone plasma levels in 58.2% of men. There are evidences of hypothalamus-pituitary-adrenal axis abnormalities, inappropriate aldosterone and ADH secretions, and presence of hypoparathyroidism, magnesium depletion, thyroid and testicular insufficiencies.
Vibrational modes of thin oblate clouds of charge
NASA Astrophysics Data System (ADS)
Jenkins, Thomas G.; Spencer, Ross L.
2002-07-01
A numerical method is presented for finding the eigenfunctions (normal modes) and mode frequencies of azimuthally symmetric non-neutral plasmas confined in a Penning trap whose axial thickness is much smaller than their radial size. The plasma may be approximated as a charged disk in this limit; the normal modes and frequencies can be found if the surface charge density profile σ(r) of the disk and the trap bounce frequency profile ωz(r) are known. The dependence of the eigenfunctions and equilibrium plasma shapes on nonideal components of the confining Penning trap fields is discussed. The results of the calculation are compared with the experimental data of Weimer et al. [Phys. Rev. A 49, 3842 (1994)] and it is shown that the plasma in this experiment was probably hollow and had mode displacement functions that were concentrated near the center of the plasma.
Ma, Yu; Xia, Yun; Yang, Xiaolan; Yu, Ming'an
2003-06-01
Virus inactivation of plasma can be achieved by phototreatment with methylene blue (MB). Subsequently, elimination of MB may reduce the adverse effects of MB. This study examined the effects of adsorbing MB with the use of cross-linked agar bead entrapped attapulgite clay (CAA) on normal ingredients in MB-treated plasma units. The biomedical characteristics of CAA were assessed by determination of partial biochemical indexes, coagulation potency and some cationic concentration in a control sample and the MB-treated plasma eluted from CAA column. The biochemistry indexes or K+, Na+ in plasma were almost unaltered before and after CAA adsorption. In contrast, the concentrations of CA2+ and Mg2+ increased and the blood ammonium decreased obviously. The activated partial thromboplastin time (APTT) was prolonged from 42 s to 53 s, and prothrombin time (PT) from 13 s to 14 s. The result indicates that CAA as an adsorbent for hemopurification retains the most important characters of human plasma. CAA can be useful for the elimination of MB in MB-treated plasma and does not bring on harmful alteration in clinical significance.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Si, Hang; Guo, Houyang Y.; Covele, Brent
One of the major challenges facing the design and operation of next-step high-power steady-state fusion devices is to develop a divertor solution for handling power exhaust, while ensuring acceptable divertor target plate erosion, which necessitates access to divertor detachment at relative low main plasma densities compatible with current drive and high plasma confinement. Detailed modeling with SOLPS is carried out to examine the effect of divertor closure on detachment with the normal single null divertor (SD) configuration, as well as one of the advanced divertor configurations, such as x-divertor (XD) respectively. The SOLPS modeling for a high confinement plasma in DIII-D finds that increasing divertor closure with SD reduces the upstream separatrix density at the onset of detachment frommore » $$1.18\\times {{10}^{19}}\\,{{{\\rm m}}^{-3}}$$ to $$0.88\\times {{10}^{19}}\\,{{{\\rm m}}^{-3}}$$. Furthermore, coupling the divertor closure with XD further promotes the onset of divertor detachment at a still lower upstream separatrix density, down to the value of $$0.67\\times {{10}^{19}}\\,{{{\\rm m}}^{-3}}$$, thus, showing that divertor closure and advanced magnetic configuration can work synergistically to facilitate divertor detachment.« less
Si, Hang; Guo, Houyang Y.; Covele, Brent; ...
2018-04-04
One of the major challenges facing the design and operation of next-step high-power steady-state fusion devices is to develop a divertor solution for handling power exhaust, while ensuring acceptable divertor target plate erosion, which necessitates access to divertor detachment at relative low main plasma densities compatible with current drive and high plasma confinement. Detailed modeling with SOLPS is carried out to examine the effect of divertor closure on detachment with the normal single null divertor (SD) configuration, as well as one of the advanced divertor configurations, such as x-divertor (XD) respectively. The SOLPS modeling for a high confinement plasma in DIII-D finds that increasing divertor closure with SD reduces the upstream separatrix density at the onset of detachment frommore » $$1.18\\times {{10}^{19}}\\,{{{\\rm m}}^{-3}}$$ to $$0.88\\times {{10}^{19}}\\,{{{\\rm m}}^{-3}}$$. Furthermore, coupling the divertor closure with XD further promotes the onset of divertor detachment at a still lower upstream separatrix density, down to the value of $$0.67\\times {{10}^{19}}\\,{{{\\rm m}}^{-3}}$$, thus, showing that divertor closure and advanced magnetic configuration can work synergistically to facilitate divertor detachment.« less
Experimental Investigation of Pseudospark generated electron beam
NASA Astrophysics Data System (ADS)
Kumar, Niraj; Verma, D. K.; Prajapati, J.; Kumar, M.; Meena, B. L.; Tyagi, M. S.; Srivastava, V.; Pal, U. N.
2012-11-01
The pseudospark (PS) discharge is, however, more recently recognized as a different type of discharge which is capable of generating electron beams with the highest combined current density and brightness of any known type of electron source. PS discharge is a specific type of gas discharge, which operates on the left-hand side of the hollow cathode analogy to the Paschen curve with axially symmetric parallel electrodes and central holes on the electrodes. The PS discharge generated electron beam has tremendous applications in plasma filled microwave sources where normal material cathode cannot be used. Analysis of the electron beam profile has been carried out experimentally for different applied voltages. The investigation has been done at different axial and radial location inside the drift tube in argon atmosphere. This paper represents experimentally derived axial and radial variation of the beam current inside the plasma filled drift tube of PS discharge based plasma cathode electron (PCE) gun. With the help of current density estimation the focusing and defocusing point of electron beam in axial direction can be analyzed. It has been further confirmed the successful propagation of electron beam in confined manner without any assistance of external magnetic field.
B{sub 4}C-SiC reaction-sintered coatings on graphite plasma facing components
DOE Office of Scientific and Technical Information (OSTI.GOV)
Valentine, P.G.; Trester, P.W.; Winter, J.
1994-05-01
Boron carbide plus silicon carbide (B{sub 4}C-SiC) reaction-sintered coatings for use on graphite plasma-facing components were developed. Such coatings are of interest in TEXTOR tokamak limiter-plasma interactions as a means of reducing carbon erosion, of providing a preferred release of boron for oxygen gettering, and of investigating silicon`s effect on radiative edge phenomena. Specimens evaluated had (a) either Ringsdorfwerke EK 98 graphite or Le Carbon Lorraine felt-type AEROLOR A05 CFC substrates; (b) multiphase coatings, comprised of B{sub 4}C, Sic, and graphite; (c) nominal coating compositions of 69 wt.-% B{sub 4}C + 31 wt.-% SiC; and (d) nominal coating thicknesses betweenmore » 250 and 775 {mu}m. Coated coupons were evaluated by high heat flux experiments in the JUDITH (electron beam) test facility at KFA. Simulated disruptions, with energy densities up to 10 MJm{sup {minus}2}, and normal operation simulations, with power densities up to 12 MWm{sup {minus}2}, were conducted. The coatings remained adherent; at the highest levels tested, minor changes occurred, including localized remelting, modification of the crystallographic phases, occasional microcracking, and erosion.« less
NASA Astrophysics Data System (ADS)
Si, H.; Guo, H. Y.; Covele, B.; Leonard, A. W.; Watkins, J. G.; Thomas, D.; Ding, R.
2018-05-01
One of the major challenges facing the design and operation of next-step high-power steady-state fusion devices is to develop a divertor solution for handling power exhaust, while ensuring acceptable divertor target plate erosion, which necessitates access to divertor detachment at relative low main plasma densities compatible with current drive and high plasma confinement. Detailed modeling with SOLPS is carried out to examine the effect of divertor closure on detachment with the normal single null divertor (SD) configuration, as well as one of the advanced divertor configurations, such as x-divertor (XD) respectively. The SOLPS modeling for a high confinement plasma in DIII-D finds that increasing divertor closure with SD reduces the upstream separatrix density at the onset of detachment from 1.18× {{10}19} {{m}-3} to 0.88× {{10}19} {{m}-3} . Moreover, coupling the divertor closure with XD further promotes the onset of divertor detachment at a still lower upstream separatrix density, down to the value of 0.67× {{10}19} {{m}-3} , thus, showing that divertor closure and advanced magnetic configuration can work synergistically to facilitate divertor detachment.
Large-Area Permanent-Magnet ECR Plasma Source
NASA Technical Reports Server (NTRS)
Foster, John E.
2007-01-01
A 40-cm-diameter plasma device has been developed as a source of ions for material-processing and ion-thruster applications. Like the device described in the immediately preceding article, this device utilizes electron cyclotron resonance (ECR) excited by microwave power in a magnetic field to generate a plasma in an electrodeless (noncontact) manner and without need for an electrically insulating, microwave-transmissive window at the source. Hence, this device offers the same advantages of electrodeless, windowless design - low contamination and long operational life. The device generates a uniform, high-density plasma capable of sustaining uniform ion-current densities at its exit plane while operating at low pressure [<10(exp -4) torr (less than about 1.3 10(exp -2) Pa)] and input power <200 W at a frequency of 2.45 GHz. Though the prototype model operates at 2.45 GHz, operation at higher frequencies can be achieved by straightforward modification to the input microwave waveguide. Higher frequency operation may be desirable in those applications that require even higher background plasma densities. In the design of this ECR plasma source, there are no cumbersome, power-hungry electromagnets. The magnetic field in this device is generated by a permanent-magnet circuit that is optimized to generate resonance surfaces. The microwave power is injected on the centerline of the device. The resulting discharge plasma jumps into a "high mode" when the input power rises above 150 W. This mode is associated with elevated plasma density and high uniformity. The large area and uniformity of the plasma and the low operating pressure are well suited for such material-processing applications as etching and deposition on large silicon wafers. The high exit-plane ion-current density makes it possible to attain a high rate of etching or deposition. The plasma potential is <3 V low enough that there is little likelihood of sputtering, which, in plasma processing, is undesired because it is associated with erosion and contamination. The electron temperature is low and does not vary appreciably with power.
Plasma Properties of Microwave Produced Plasma in a Toroidal Device
NASA Astrophysics Data System (ADS)
Singh, Ajay; Edwards, W. F.; Held, Eric
2011-10-01
We have modified a small tokamak, STOR-1M, on loan from University of Saskatchewan, to operate as a low-temperature (~5 eV) toroidal plasma machine with externally induced toroidal magnetic fields ranging from zero to ~50 G. The plasma is produced using microwave discharges at relatively high pressures. Microwaves are produced by a kitchen microwave-oven magnetron operating at 2.45 GHz in continuous operating mode, resulting in pulses ~0.5 s in duration. Initial measurements of plasma formation in this device with and without applied magnetic fields are presented. Plasma density and temperature profiles have been measured using Langmuir probes and the magnetic field profile inside the plasma has been obtained using Hall probes. When the discharge is created with no applied toroidal magnetic field, the plasma does not fill the entire torus due to high background pressure. However, when a toroidal magnetic field is applied, the plasma flows along the applied field, filling the torus. Increasing the applied magnetic field seems to aid plasma formation - the peak density increases and the density gradient becomes steeper. Above a threshold magnetic field, the plasma develops low-frequency density oscillations due to probable excitation of flute modes in the plasma.
High beta plasma operation in a toroidal plasma producing device
Clarke, John F.
1978-01-01
A high beta plasma is produced in a plasma producing device of toroidal configuration by ohmic heating and auxiliary heating. The plasma pressure is continuously monitored and used in a control system to program the current in the poloidal field windings. Throughout the heating process, magnetic flux is conserved inside the plasma and the distortion of the flux surfaces drives a current in the plasma. As a consequence, the total current increases and the poloidal field windings are driven with an equal and opposing increasing current. The spatial distribution of the current in the poloidal field windings is determined by the plasma pressure. Plasma equilibrium is maintained thereby, and high temperature, high beta operation results.
Coupled microwave ECR and radio-frequency plasma source for plasma processing
Tsai, Chin-Chi; Haselton, Halsey H.
1994-01-01
In a dual plasma device, the first plasma is a microwave discharge having its own means of plasma initiation and control. The microwave discharge operates at electron cyclotron resonance (ECR), and generates a uniform plasma over a large area of about 1000 cm.sup.2 at low pressures below 0.1 mtorr. The ECR microwave plasma initiates the second plasma, a radio frequency (RF) plasma maintained between parallel plates. The ECR microwave plasma acts as a source of charged particles, supplying copious amounts of a desired charged excited species in uniform manner to the RF plasma. The parallel plate portion of the apparatus includes a magnetic filter with static magnetic field structure that aids the formation of ECR zones in the two plasma regions, and also assists in the RF plasma also operating at electron cyclotron resonance.
Coupled microwave ECR and radio-frequency plasma source for plasma processing
Tsai, C.C.; Haselton, H.H.
1994-03-08
In a dual plasma device, the first plasma is a microwave discharge having its own means of plasma initiation and control. The microwave discharge operates at electron cyclotron resonance (ECR), and generates a uniform plasma over a large area of about 1000 cm[sup 2] at low pressures below 0.1 mtorr. The ECR microwave plasma initiates the second plasma, a radio frequency (RF) plasma maintained between parallel plates. The ECR microwave plasma acts as a source of charged particles, supplying copious amounts of a desired charged excited species in uniform manner to the RF plasma. The parallel plate portion of the apparatus includes a magnetic filter with static magnetic field structure that aids the formation of ECR zones in the two plasma regions, and also assists in the RF plasma also operating at electron cyclotron resonance. 4 figures.
Nonextensive GES instability with nonlinear pressure effects
NASA Astrophysics Data System (ADS)
Gohain, Munmi; Karmakar, Pralay Kumar
2018-03-01
We herein analyze the instability dynamics associated with the nonextensive nonthermal gravito-electrostatic sheath (GES) model for the perturbed solar plasma portraiture. The usual neutral gas approximation is herewith judiciously relaxed and the laboratory plasma-wall interaction physics is procedurally incorporated amid barotropic nonlinearity. The main motivation here stems from the true nature of the solar plasma system as a set of concentric nonlocal nonthermal sub-layers as evidenced from different multi-space satellite probes and missions. The formalism couples the solar interior plasma (SIP, bounded) and solar wind plasma (SWP, unbounded) via the diffused solar surface boundary (SSB) formed due to an exact long-range gravito-electrostatic force-equilibration. A linear normal mode ansatz reveals both dispersive and non-dispersive features of the modified GES collective wave excitations. It is seen that the thermostatistical GES stability depends solely on the electron-to-ion temperature ratio. The damping behavior on both the scales is more pronounced in the acoustic domain, K → ∞ , than the gravitational domain, K → 0 ; where, K is the Jeans-normalized angular wave number. It offers a unique quasi-linear coupling of the gravitational and acoustic fluctuations amid the GES force action. The results may be useful to see the excitation dynamics of natural normal modes in bounded nonextensive astero-environs from a new viewpoint of the plasma-wall coupling mechanism.
NASA Astrophysics Data System (ADS)
Colgan, James
2016-05-01
We report on efforts to model the low-temperature plasmas generated using laser-induced breakdown spectroscopy (LIBS). LIBS is a minimally invasive technique that can quickly and efficiently determine the elemental composition of a target and is employed in an extremely wide range of applications due to its ease of use and fast turnaround. In particular, LIBS is the diagnostic tool used by the ChemCam instrument on the Mars Science Laboratory rover Curiosity. In this talk, we report on the use of the Los Alamos plasma modeling code ATOMIC to simulate LIBS plasmas, which are typically at temperatures of order 1 eV and electron densities of order 10 16 - 17 cm-3. At such conditions, these plasmas are usually in local-thermodynamic equilibrium (LTE) and normally contain neutral and singly ionized species only, which then requires that modeling must use accurate atomic structure data for the element under investigation. Since LIBS devices are often employed in a very wide range of applications, it is therefore desirable to have accurate data for most of the elements in the periodic table, ideally including actinides. Here, we discuss some recent applications of our modeling using ATOMIC that have explored the plasma physics aspects of LIBS generated plasmas, and in particular discuss the modeling of a plasma formed from a basalt sample used as a ChemCam standard1. We also highlight some of the more general atomic physics challenges that are encountered when attempting to model low-temperature plasmas. The Los Alamos National Laboratory is operated by Los Alamos National Security, LLC for the National Nuclear Security Administration of the U.S. Department of Energy under Contract No. DE-AC5206NA25396. Work performed in conjunction with D. P. Kilcrease, H. M. Johns, E. J. Judge, J. E. Barefield, R. C. Wiens, S. M. Clegg.
Obesity-Related Metabolic Risk in Sedentary Hispanic Adolescent Girls with Normal BMI.
van der Heijden, Gert-Jan; Wang, Zhiyue J; Chu, Zili D; Haymond, Morey; Sauer, Pieter J J; Sunehag, Agneta L
2018-06-15
Hispanic adolescent girls with normal BMI frequently have high body fat %. Without knowledge of body fat content and distribution, their risk for metabolic complications is unknown. We measured metabolic risk indicators and abdominal fat distribution in post-pubertal Hispanic adolescent girls with Normal BMI (N-BMI: BMI < 85th percentile) and compared these indicators between girls with Normal BMI and High Fat content (N-BMI-HF: body fat ≥ 27%; n = 15) and Normal BMI and Normal Fat content (N-BMI-NF: body fat < 27%; n = 8). Plasma concentrations of glucose, insulin, adiponectin, leptin and Hs-CRP were determined. Insulin resistance was calculated using an oral glucose tolerance test. Body fat % was measured by DXA and subcutaneous, visceral and hepatic fat by MRI/MRS. The N-BMI-HF girls had increased abdominal and hepatic fat content and increased insulin resistance, plasma leptin and Hs-CRP concentrations ( p < 0.05) as compared to their N-BMI-NF counterparts. In N-BMI girls, insulin resistance, plasma insulin and leptin correlated with BMI and body fat % ( p < 0.05). This research confirms the necessity of the development of BMI and body fat % cut-off criteria per sex, age and racial/ethnic group based on metabolic risk factors to optimize the effectiveness of metabolic risk screening procedures.
Plasma-electric field controlled growth of oriented graphene for energy storage applications
NASA Astrophysics Data System (ADS)
Ghosh, Subrata; Polaki, S. R.; Kamruddin, M.; Jeong, Sang Mun; (Ken Ostrikov, Kostya
2018-04-01
It is well known that graphene grows as flat sheets aligned with the growth substrate. Oriented graphene structures typically normal to the substrate have recently attracted major attention. Most often, the normal orientation is achieved in a plasma-assisted growth and is believed to be due to the plasma-induced in-built electric field, which is usually oriented normal to the substrate. This work focuses on the effect of an in-built electric field on the growth direction, morphology, interconnectedness, structural properties and also the supercapacitor performance of various configurations of graphene structures and reveals the unique dependence of these features on the electric field orientation. It is shown that tilting of growth substrates from parallel to the normal direction with respect to the direction of in-built plasma electric field leads to the morphological transitions from horizontal graphene layers, to oriented individual graphene sheets and then interconnected 3D networks of oriented graphene sheets. The revealed transition of the growth orientation leads to a change in structural properties, wetting nature, types of defect in graphitic structures and also affects their charge storage capacity when used as supercapacitor electrodes. This simple and versatile approach opens new opportunities for the production of potentially large batches of differently oriented and structured graphene sheets in one production run.
21 CFR 866.5150 - Bence-Jones proteins immunological test system.
Code of Federal Regulations, 2010 CFR
2010-04-01
... the Bence-Jones proteins in urine and plasma. Immunoglobulin molecules normally consist of pairs of... disulfide bridges. In some cancerous conditions, there is a proliferation of one plasma cell (antibody... plasma, and have been called Bence-Jones proteins. Measurement of Bence-Jones proteins and determination...
21 CFR 866.5150 - Bence-Jones proteins immunological test system.
Code of Federal Regulations, 2012 CFR
2012-04-01
... the Bence-Jones proteins in urine and plasma. Immunoglobulin molecules normally consist of pairs of... disulfide bridges. In some cancerous conditions, there is a proliferation of one plasma cell (antibody... plasma, and have been called Bence-Jones proteins. Measurement of Bence-Jones proteins and determination...
21 CFR 866.5150 - Bence-Jones proteins immunological test system.
Code of Federal Regulations, 2011 CFR
2011-04-01
... the Bence-Jones proteins in urine and plasma. Immunoglobulin molecules normally consist of pairs of... disulfide bridges. In some cancerous conditions, there is a proliferation of one plasma cell (antibody... plasma, and have been called Bence-Jones proteins. Measurement of Bence-Jones proteins and determination...
21 CFR 866.5150 - Bence-Jones proteins immunological test system.
Code of Federal Regulations, 2013 CFR
2013-04-01
... the Bence-Jones proteins in urine and plasma. Immunoglobulin molecules normally consist of pairs of... disulfide bridges. In some cancerous conditions, there is a proliferation of one plasma cell (antibody... plasma, and have been called Bence-Jones proteins. Measurement of Bence-Jones proteins and determination...
21 CFR 866.5150 - Bence-Jones proteins immunological test system.
Code of Federal Regulations, 2014 CFR
2014-04-01
... the Bence-Jones proteins in urine and plasma. Immunoglobulin molecules normally consist of pairs of... disulfide bridges. In some cancerous conditions, there is a proliferation of one plasma cell (antibody... plasma, and have been called Bence-Jones proteins. Measurement of Bence-Jones proteins and determination...
Reduced growth factor requirement of keloid-derived fibroblasts may account for tumor growth
DOE Office of Scientific and Technical Information (OSTI.GOV)
Russell, S.B.; Trupin, K.M.; Rodriguez-Eaton, S.
Keloids are benign dermal tumors that form during an abnormal wound-healing process is genetically susceptible individuals. Although growth of normal and keloid cells did not differ in medium containing 10% (vol/vol) fetal bovine serum, keloid culture grew to significantly higher densities than normal cells in medium containing 5% (vol/vol) fetal bovine serum, keloid cultures grew to significantly higher densities than normal cells in medium containing 5% (vol/vol) plasma or 1% fetal bovine serum. Conditioned medium from keloid cultures did not stimulate growth of normal cells in plasma nor did it contain detectable platelet-derived growth factor or epidermal growth factor. Keloidmore » fibroblasts responded differently than normal adult fibroblasts to transforming growth factor ..beta... Whereas transforming growth factor ..beta.. reduced growth stimulation by epidermal growth factor in cells from normal adult skin or scars, it enhanced the activity of epidermal growth factor in cells from normal adult skin or scars, it enhanced the activity of epidermal growth factor in cells from keloids. Normal and keloid fibroblasts also responded differently to hydrocortisone: growth was stimulated in normal adult cells and unaffected or inhibited in keloid cells. Fetal fibroblasts resembled keloid cells in their ability to grow in plasma and in their response to hydrocortisone. The ability of keloid fibroblasts to grow to higher cell densities in low-serum medium than cells from normal adult skin or from normal early or mature scars suggests that a reduced dependence on serum growth factors may account for their prolonged growth in vivo. Similarities between keloid and fetal cells suggest that keloids may result from the untimely expression of growth-control mechanism that is developmentally regulated.« less
Radioimmunoassay of ACTH in plasma
Berson, Solomon A.; Yalow, Rosalyn S.
1968-01-01
Techniques are described in detail for a radioimmunoassay of plasma adrenocorticotropin (ACTH) that is capable of detecting hormone in unextracted normal human plasma at 1:5 dilution under the conditions described. The sensitivity of the assay is at the level of 1 μμg/ml (equivalent to 0.014 mU/100 ml). In normal subjects ACTH concentrations averaged 22 μμg/ml (equivalent to 0.308 mU/100 ml) plasma at 8-10 a.m. In a smaller group the concentrations averaged 9.6 μμg/ml (equivalent to 0.134 mU/100 ml) at 10-11 p.m. Although a circadian rhythm in normal subjects was not always well marked throughout the daytime hours, plasma ACTH usually fell to its lowest value in the late evening. In hospital patients who were not acutely ill, concentrations were infrequently above 100 μμg/ml in the morning and usually fell to significantly lower levels in the late evening. Severely ill hospital patients occasionally exhibited a.m. concentrations above 200 μμg/ml. In a group of subjects showing frequent spiking of plasma 17-OHCS concentrations throughout the day parallel spiking of plasma ACTH as well was generally observed. Metyrapone produced marked increases in plasma ACTH within 24 hr in all cases and generally within 3-6 hr except when started late in the day. Dexamethasone brought about a persistent reduction in plasma ACTH in a patient under continued treatment with metyrapone. Hypoglycemia, electroshock, surgery under general anesthesia, histalog and vasopressin administration were usually followed by significant increases in plasma ACTH concentration. Prior administration of dexamethasone blocked the response to hypoglycemia. Marked elevations in plasma ACTH were observed in patients with adrenal insufficiency off steroid therapy, in Cushing's disease after adrenalectomy even in the presence of persistent hypercortisolemia, and in some untreated patients with Cushing's disease. Umbilical cord blood contained higher plasma ACTH concentrations than maternal blood at delivery in seven of eight cases. After suppression of ACTH secretion by dexamethasone or cortisol. ACTH disappeared from plasma with half-times ranging from 22 min to 30 min in three cases studied. Images PMID:4302180
Evidence for a reduced heparin cofactor II biological activity in diabetes.
Ceriello, A; Quatraro, A; Dello Russo, P; Marchi, E; Milani, M R; Giugliano, D
1990-01-01
A reduction of heparin cofactor II (HCII) biological activity, despite its normal plasma concentration, is reported in insulin-dependent diabetic patients. A good linear correlation between HCII activity and concentration is present in normal controls but not in diabetics. In these subjects HCII activity correlates inversely with fasting blood glucose and glycated proteins but not with Hb A1. These data demonstrate the presence of a depressed HCII activity in the presence of its normal plasma concentration in insulin-dependent diabetics and suggest a role for short-term metabolic control in conditioning this phenomenon.
Higashiguchi, Takeshi; Hamada, Masaya; Kubodera, Shoichi
2007-03-01
A regenerative tin liquid microjet target was developed for a high average power extreme ultraviolet (EUV) source. The diameter of the target was smaller than 160 microm and good vacuum lower than 0.5 Pa was maintained during the operation. A maximum EUV conversion efficiency of 1.8% at the Nd:yttrium-aluminum-garnet laser intensity of around 2 x 10(11) Wcm(2) with a spot diameter of 175 microm (full width at half maximum) was observed. The angular distribution of the EUV emission remained almost isotropic, whereas suprathermal ions mainly emerged toward the target normal.
NASA Astrophysics Data System (ADS)
Higashiguchi, Takeshi; Hamada, Masaya; Kubodera, Shoichi
2007-03-01
A regenerative tin liquid microjet target was developed for a high average power extreme ultraviolet (EUV) source. The diameter of the target was smaller than 160 μm and good vacuum lower than 0.5 Pa was maintained during the operation. A maximum EUV conversion efficiency of 1.8% at the Nd:yttrium-aluminum-garnet laser intensity of around 2×1011 W/cm2 with a spot diameter of 175 μm (full width at half maximum) was observed. The angular distribution of the EUV emission remained almost isotropic, whereas suprathermal ions mainly emerged toward the target normal.
NASA Technical Reports Server (NTRS)
Kamhawi, Hani; Yim, John T.; Patterson, Michael J.; Dalton, Penni J.
2013-01-01
The International Space Station has onboard two Aerojet Rocketdyne developed plasma contactor units that perform the function of charge control. The plasma contactor units contain NASA Glenn Research Center developed hollow cathode assemblies. NASA Glenn Research Center monitors the on-orbit operation of the flight hollow cathode assemblies. As of May 31, 2013, HCA.001-F has been ignited and operated 123 times and has accumulated 8072 hours of operation, whereas, HCA.003-F has been ignited and operated 112 times and has accumulated 9664 hours of operation. Monitored hollow cathode ignition times and anode voltage magnitudes indicate that they continue to operate nominally.
NASA Technical Reports Server (NTRS)
Kamhawi, Hani; Yim, John T.; Patterson, Michael J.; Dalton, Penni J.
2014-01-01
The International Space Station has onboard two Aerojet Rocketdyne developed plasma contactor units that perform the function of charge control. The plasma contactor units contain NASA Glenn Research Center developed hollow cathode assemblies. NASA Glenn Research Center monitors the onorbit operation of the flight hollow cathode assemblies. As of May 31, 2013, HCA.001-F has been ignited and operated 123 times and has accumulated 8072 hours of operation, whereas, HCA.003-F has been ignited and operated 112 times and has accumulated 9664 hours of operation. Monitored hollow cathode ignition times and anode voltage magnitudes indicate that they continue to operate nominally.
Plasma gasification of municipal solid waste
DOE Office of Scientific and Technical Information (OSTI.GOV)
Carter, G.W.; Tsangaris, A.V.
1995-12-31
Resorption Canada Limited (RCL) has conducted extensive operational testing with plasma technology in their plasma facility near Ottawa, Ontario, Canada to develop an environmentally friendly waste disposal process. Plasma technology, when utilized in a reactor vessel with the exclusion of oxygen, provides for the complete gasification of all combustibles in source materials with non-combustibles being converted to a non-hazardous slag. The energy and environmental characteristics of the plasma gasification of carbonaceous waste materials were studied over a period of eight years during which RCL completed extensive experimentation with MSW. A plasma processing system capable of processing 200--400 lbs/hr of MSWmore » was designed and built. The experimentation on MSW concentrated on establishing the optimum operating parameters and determining the energy and environmental characteristics at these operating parameters.« less
Min, Yong Ki; Suh, Kyo II; Choi, Sang Jeon; Lee, Hong Kyu; Kim, Chung Yong; Koh, Chang-Soon; Min, Hun Ki
1987-01-01
To elucidate the mechanism of glucose intolerance in patients with chronic liver disease(CLD), we measured the levels of plasma glucose, insulin and C-peptide during oral glucose tolerance test and urinary excretion of C-peptide per 24 hours during a weight maintenance diet in 20 patients with CLD who had fasting plasma glucose(FBS) of less than 100 mg/dl. The patients with CLD who had normal FBS(FBS less than 100 mg/dl) were divided into two groups by the National Diabetes Data Group Criteria: one with abnormal glucose tolerance (abnormal GTT, Group 1) and the other with normal glucose tolerance (normal GTT. Group 2). Group 1 patients showed significantly higher plasma insulin (p<0.02 and p<0.01, respectively) and C-peptide concentrations (p<0.01) in the fasting state and 2 hours after a 75gram oral glucose loading (PP2) than group 2 patients. Urinary excretion of C-peptide per 24 hours was also higher in group 1 patients than in group 2 patients (p<0.01). Group 2 patients demonstrated similar plasma insulin, C-peptide and urinary excretion of C-peptide per 24 hours to normal subjects (p>0.05). These results suggest that patients with CLD who had normal FBS can be divided into two groups by oral glucose tolerance test(GTT) and those with abnormal GTT have hyperinsulinemia the mechanism of which is insulin hypersecretion from pancreatic B-cell. PMID:3154815
NASA Astrophysics Data System (ADS)
Goto, T.; Miyazawa, J.; Sakamoto, R.; Suzuki, Y.; Suzuki, C.; Seki, R.; Satake, S.; Huang, B.; Nunami, M.; Yokoyama, M.; Sagara, A.; the FFHR Design Group
2017-06-01
This study closely investigates the plasma operation scenario for the LHD-type helical reactor FFHR-d1 in view of MHD equilibrium/stability, neoclassical transport, alpha energy loss and impurity effect. In 1D calculation code that reproduces the typical pellet discharges in LHD experiments, we identify a self-consistent solution of the plasma operation scenario which achieves steady-state sustainment of the burning plasma with a fusion gain of Q ~ 10 was found within the operation regime that has been already confirmed in LHD experiment. The developed calculation tool enables systematic analysis of the operation regime in real time.
In-situ plasma processing to increase the accelerating gradients of SRF cavities
Doleans, Marc; Afanador, Ralph; Barnhart, Debra L.; ...
2015-12-31
A new in-situ plasma processing technique is being developed at the Spallation Neutron Source (SNS) to improve the performance of the cavities in operation. The technique utilizes a low-density reactive oxygen plasma at room temperature to remove top surface hydrocarbons. The plasma processing technique increases the work function of the cavity surface and reduces the overall amount of vacuum and electron activity during cavity operation; in particular it increases the field emission onset, which enables cavity operation at higher accelerating gradients. Experimental evidence also suggests that the SEY of the Nb surface decreases after plasma processing which helps mitigating multipactingmore » issues. This article discusses the main developments and results from the plasma processing R&D are presented and experimental results for in-situ plasma processing of dressed cavities in the SNS horizontal test apparatus.« less
Contribution of Tore Supra in preparation of ITER
NASA Astrophysics Data System (ADS)
Saoutic, B.; Abiteboul, J.; Allegretti, L.; Allfrey, S.; Ané, J. M.; Aniel, T.; Argouarch, A.; Artaud, J. F.; Aumenier, M. H.; Balme, S.; Basiuk, V.; Baulaigue, O.; Bayetti, P.; Bécoulet, A.; Bécoulet, M.; Benkadda, M. S.; Benoit, F.; Berger-by, G.; Bernard, J. M.; Bertrand, B.; Beyer, P.; Bigand, A.; Blum, J.; Boilson, D.; Bonhomme, G.; Bottollier-Curtet, H.; Bouchand, C.; Bouquey, F.; Bourdelle, C.; Bourmaud, S.; Brault, C.; Brémond, S.; Brosset, C.; Bucalossi, J.; Buravand, Y.; Cara, P.; Catherine-Dumont, V.; Casati, A.; Chantant, M.; Chatelier, M.; Chevet, G.; Ciazynski, D.; Ciraolo, G.; Clairet, F.; Coatanea-Gouachet, M.; Colas, L.; Commin, L.; Corbel, E.; Corre, Y.; Courtois, X.; Dachicourt, R.; Dapena Febrer, M.; Davi Joanny, M.; Daviot, R.; De Esch, H.; Decker, J.; Decool, P.; Delaporte, P.; Delchambre, E.; Delmas, E.; Delpech, L.; Desgranges, C.; Devynck, P.; Dittmar, T.; Doceul, L.; Douai, D.; Dougnac, H.; Duchateau, J. L.; Dugué, B.; Dumas, N.; Dumont, R.; Durocher, A.; Duthoit, F. X.; Ekedahl, A.; Elbeze, D.; El Khaldi, M.; Escourbiac, F.; Faisse, F.; Falchetto, G.; Farge, M.; Farjon, J. L.; Faury, M.; Fedorczak, N.; Fenzi-Bonizec, C.; Firdaouss, M.; Frauel, Y.; Garbet, X.; Garcia, J.; Gardarein, J. L.; Gargiulo, L.; Garibaldi, P.; Gauthier, E.; Gaye, O.; Géraud, A.; Geynet, M.; Ghendrih, P.; Giacalone, I.; Gibert, S.; Gil, C.; Giruzzi, G.; Goniche, M.; Grandgirard, V.; Grisolia, C.; Gros, G.; Grosman, A.; Guigon, R.; Guilhem, D.; Guillerminet, B.; Guirlet, R.; Gunn, J.; Gurcan, O.; Hacquin, S.; Hatchressian, J. C.; Hennequin, P.; Hernandez, C.; Hertout, P.; Heuraux, S.; Hillairet, J.; Hoang, G. T.; Honore, C.; Houry, M.; Hutter, T.; Huynh, P.; Huysmans, G.; Imbeaux, F.; Joffrin, E.; Johner, J.; Jourd'Heuil, L.; Katharria, Y. S.; Keller, D.; Kim, S. H.; Kocan, M.; Kubic, M.; Lacroix, B.; Lamaison, V.; Latu, G.; Lausenaz, Y.; Laviron, C.; Leroux, F.; Letellier, L.; Lipa, M.; Litaudon, X.; Loarer, T.; Lotte, P.; Madeleine, S.; Magaud, P.; Maget, P.; Magne, R.; Manenc, L.; Marandet, Y.; Marbach, G.; Maréchal, J. L.; Marfisi, L.; Martin, C.; Martin, G.; Martin, V.; Martinez, A.; Martins, J. P.; Masset, R.; Mazon, D.; Mellet, N.; Mercadier, L.; Merle, A.; Meshcheriakov, D.; Meyer, O.; Million, L.; Missirlian, M.; Mollard, P.; Moncada, V.; Monier-Garbet, P.; Moreau, D.; Moreau, P.; Morini, L.; Nannini, M.; Naiim Habib, M.; Nardon, E.; Nehme, H.; Nguyen, C.; Nicollet, S.; Nouilletas, R.; Ohsako, T.; Ottaviani, M.; Pamela, S.; Parrat, H.; Pastor, P.; Pecquet, A. L.; Pégourié, B.; Peysson, Y.; Porchy, I.; Portafaix, C.; Preynas, M.; Prou, M.; Raharijaona, J. M.; Ravenel, N.; Reux, C.; Reynaud, P.; Richou, M.; Roche, H.; Roubin, P.; Sabot, R.; Saint-Laurent, F.; Salasca, S.; Samaille, F.; Santagiustina, A.; Sarazin, Y.; Semerok, A.; Schlosser, J.; Schneider, M.; Schubert, M.; Schwander, F.; Ségui, J. L.; Selig, G.; Sharma, P.; Signoret, J.; Simonin, A.; Song, S.; Sonnendruker, E.; Sourbier, F.; Spuig, P.; Tamain, P.; Tena, M.; Theis, J. M.; Thouvenin, D.; Torre, A.; Travère, J. M.; Tsitrone, E.; Vallet, J. C.; Van Der Plas, E.; Vatry, A.; Verger, J. M.; Vermare, L.; Villecroze, F.; Villegas, D.; Volpe, R.; Vulliez, K.; Wagrez, J.; Wauters, T.; Zani, L.; Zarzoso, D.; Zou, X. L.
2011-09-01
Tore Supra routinely addresses the physics and technology of very long-duration plasma discharges, thus bringing precious information on critical issues of long pulse operation of ITER. A new ITER relevant lower hybrid current drive (LHCD) launcher has allowed coupling to the plasma a power level of 2.7 MW for 78 s, corresponding to a power density close to the design value foreseen for an ITER LHCD system. In accordance with the expectations, long distance (10 cm) power coupling has been obtained. Successive stationary states of the plasma current profile have been controlled in real-time featuring (i) control of sawteeth with varying plasma parameters, (ii) obtaining and sustaining a 'hot core' plasma regime, (iii) recovery from a voluntarily triggered deleterious magnetohydrodynamic regime. The scrape-off layer (SOL) parameters and power deposition have been documented during L-mode ramp-up phase, a crucial point for ITER before the X-point formation. Disruption mitigation studies have been conducted with massive gas injection, evidencing the difference between He and Ar and the possible role of the q = 2 surface in limiting the gas penetration. ICRF assisted wall conditioning in the presence of magnetic field has been investigated, culminating in the demonstration that this conditioning scheme allows one to recover normal operation after disruptions. The effect of the magnetic field ripple on the intrinsic plasma rotation has been studied, showing the competition between turbulent transport processes and ripple toroidal friction. During dedicated dimensionless experiments, the effect of varying the collisionality on turbulence wavenumber spectra has been documented, giving new insight into the turbulence mechanism. Turbulence measurements have also allowed quantitatively comparing experimental results with predictions by 5D gyrokinetic codes: numerical results simultaneously match the magnitude of effective heat diffusivity, rms values of density fluctuations and wavenumber spectra. A clear correlation between electron temperature gradient and impurity transport in the very core of the plasma has been observed, strongly suggesting the existence of a threshold above which transport is dominated by turbulent electron modes. Dynamics of edge turbulent fluctuations has been studied by correlating data from fast imaging cameras and Langmuir probes, yielding a coherent picture of transport processes involved in the SOL. Corrections were made to this article on 6 January 2012. Some of the letters in the text were missing.
First operation and effect of a new tandem-type ion source based on electron cyclotron resonance
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kato, Yushi, E-mail: kato@eei.eng.osaka-u.ac.jp; Kimura, Daiju; Yano, Keisuke
A new tandem type source has been constructed on the basis of electron cyclotron resonance plasma for producing synthesized ion beams in Osaka University. Magnetic field in the first stage consists of all permanent magnets, i.e., cylindrically comb shaped one, and that of the second stage consists of a pair of mirror coil, a supplemental coil and the octupole magnets. Both stage plasmas can be individually operated, and produced ions in which is energy controlled by large bore extractor also can be transported from the first to the second stage. We investigate the basic operation and effects of the tandemmore » type electron cyclotron resonance ion source (ECRIS). Analysis of ion beams and investigation of plasma parameters are conducted on produced plasmas in dual plasmas operation as well as each single operation. We describe construction and initial experimental results of the new tandem type ion source based on ECRIS with wide operation window for aiming at producing synthesized ion beams as this new source can be a universal source in future.« less
Plasma reactor waste management systems
NASA Technical Reports Server (NTRS)
Ness, Robert O., Jr.; Rindt, John R.; Ness, Sumitra R.
1992-01-01
The University of North Dakota is developing a plasma reactor system for use in closed-loop processing that includes biological, materials, manufacturing, and waste processing. Direct-current, high-frequency, or microwave discharges will be used to produce plasmas for the treatment of materials. The plasma reactors offer several advantages over other systems, including low operating temperatures, low operating pressures, mechanical simplicity, and relatively safe operation. Human fecal material, sunflowers, oats, soybeans, and plastic were oxidized in a batch plasma reactor. Over 98 percent of the organic material was converted to gaseous products. The solids were then analyzed and a large amount of water and acid-soluble materials were detected. These materials could possibly be used as nutrients for biological systems.
Ideal MHD stability and performance of ITER steady-state scenarios with ITBs
NASA Astrophysics Data System (ADS)
Poli, F. M.; Kessel, C. E.; Chance, M. S.; Jardin, S. C.; Manickam, J.
2012-06-01
Non-inductive steady-state scenarios on ITER will need to operate with internal transport barriers (ITBs) in order to reach adequate fusion gain at typical currents of 9 MA. The large pressure gradients at the location of the internal barrier are conducive to the development of ideal MHD instabilities that may limit the plasma performance and may lead to plasma disruptions. Fully non-inductive scenario simulations with five combinations of heating and current drive sources are presented in this work, with plasma currents in the range 7-10 MA. For each configuration the linear, ideal MHD stability is analysed for variations of the Greenwald fraction and of the pressure peaking factor around the operating point, aiming at defining an operational space for stable, steady-state operations at optimized performance. It is shown that plasmas with lower hybrid heating and current drive maintain the minimum safety factor above 1.5, which is desirable in steady-state operations to avoid neoclassical tearing modes. Operating with moderate ITBs at 2/3 of the minor radius, these plasmas have a minimum safety factor above 2, are ideal MHD stable and reach Q ≳ 5 operating above the ideal no-wall limit.
Tearing mode dynamics and locking in the presence of external magnetic perturbations
NASA Astrophysics Data System (ADS)
Fridström, R.; Munaretto, S.; Frassinetti, L.; Chapman, B. E.; Brunsell, P. R.; Sarff, J. S.
2016-06-01
In normal operation, Madison Symmetric Torus (MST) [R. N. Dexter et al., Fusion Technol. 19, 131 (1991)] reversed-field pinch plasmas exhibit several rotating tearing modes (TMs). Application of a resonant magnetic perturbation (RMP) results in braking of mode rotation and, if the perturbation amplitude is sufficiently high, in a wall-locked state. The coils that produce the magnetic perturbation in MST give rise to RMPs with several toroidal harmonics. As a result, simultaneous deceleration of all modes is observed. The measured TM dynamics is shown to be in qualitative agreement with a magnetohydrodynamical model of the RMP interaction with the TM [R. Fitzpatrick, Nucl. Fusion 33, 1049 (1993)] adapted to MST. To correctly model the TM dynamics, the electromagnetic torque acting on several TMs is included. Quantitative agreement of the TM slowing-down time was obtained for a kinematic viscosity in the order of νki n≈10 -20 m2/s. Analysis of discharges with different plasma densities shows an increase of the locking threshold with increasing density. Modeling results show good agreement with the experimental trend, assuming a density-independent kinematic viscosity. Comparison of the viscosity estimates in this paper to those made previously with other techniques in MST plasmas suggests the possibility that the RMP technique may allow for estimates of the viscosity over a broad range of plasmas in MST and other devices.
Synergetic Effects of Runaway and Disruption Induced by VDE on the First Wall Damage in HL-2A
NASA Astrophysics Data System (ADS)
Song, Xianying; Yang, Jinwei; Li, Xu; Yuan, Guoliang; Zhang, Yipo
2012-03-01
The plasma facing component in HL-2A has been damaged seriously after disruption, and for this reason its operation is suspended for maintenance. The experimental phenomena and plasma configurations, calculated by the current filament code (CF-code) using the plasma parameters measured by diagnostics and the signals of the magnetic probes, confirm that the first wall is damaged by the synergetic effects of runaway electrons and disruption induced by a vertical displacement event (VDE). When the plasma column is displaced upward/downward, the strong runaway electrons normally hit the baffle plate of the MP3 or MP1 coil in the upper and lower divertor during the disruption, causing the baffle plates to be holed and wrinkled by the energetic runaway current, and water (for cooling or heating the baffle plates) to leak into the vacuum vessel. Another disastrous consequence is that bellows underlying the baffle plate and outside the coil of MP3 for connecting two segments of the jacket casing pipe are punctured by arcing. The arc may be part of the halo current that forms a complete circuit. The experimental phenomena are indirect but compelling evidence for the existence of a halo current during the disruption and VDE, though the halo current has not been measured by the diagnostics in the HL-2A tokamak.
Severe polyuria after the resection of adrenal pheochromocytoma.
Tobe, Musashi; Ito, Keiichi; Umeda, Shun; Sato, Akinori; Adaniya, Noriaki; Tanaka, Yuji; Hayakawa, Masamichi; Asano, Tomohiko
2010-12-01
A 73-year-old male patient with hypertension and hyperglycemia was referred to our hospital because of a diagnosis regarding his left adrenal tumor. Because the levels of urinary metanephrine and normetanephrine were elevated, and (131) I-MIBG scintigraphy showed intense uptake in the adrenal tumor, the tumor was diagnosed as a pheochromocytoma. An adrenalectomy was carried out. Severe polyuria, which was accompanied by a rapid decrease in central venous pressure, started 1 hour after the operation. Urine output of more than 8000 mL/day continued until the 16th postoperative day. Plasma antidiuretic hormone (ADH) levels were within the normal range. Plasma human atrial natriuretic peptide (hANP) and brain natriuretic peptide (BNP) were elevated postoperatively, and the elevation of these peptides was one possible cause for the severe polyuria. Because ADH levels in the tumor fluid were not elevated, the tumor was not an ADH-secreting tumor. Urinary β2-microglobulin was significantly elevated after the operation, thus suggesting that renal tubule dysfunction might also have been involved in the polyuria. However, the mechanism of polyuria after the resection of adrenal pheochromocytoma is not fully understood. Polyuria after the resection of adrenal pheochromocytoma is extremely rare, and the present subject is the second case to date. © 2010 The Japanese Urological Association.
Overview of KSTAR initial operation
NASA Astrophysics Data System (ADS)
Kwon, M.; Oh, Y. K.; Yang, H. L.; Na, H. K.; Kim, Y. S.; Kwak, J. G.; Kim, W. C.; Kim, J. Y.; Ahn, J. W.; Bae, Y. S.; Baek, S. H.; Bak, J. G.; Bang, E. N.; Chang, C. S.; Chang, D. H.; Chavdarovski, I.; Chen, Z. Y.; Cho, K. W.; Cho, M. H.; Choe, W.; Choi, J. H.; Chu, Y.; Chung, K. S.; Diamond, P.; Do, H. J.; Eidietis, N.; England, A. C.; Grisham, L.; Hahm, T. S.; Hahn, S. H.; Han, W. S.; Hatae, T.; Hillis, D.; Hong, J. S.; Hong, S. H.; Hong, S. R.; Humphrey, D.; Hwang, Y. S.; Hyatt, A.; In, Y. K.; Jackson, G. L.; Jang, Y. B.; Jeon, Y. M.; Jeong, J. I.; Jeong, N. Y.; Jeong, S. H.; Jhang, H. G.; Jin, J. K.; Joung, M.; Ju, J.; Kawahata, K.; Kim, C. H.; Kim, D. H.; Kim, Hee-Su; Kim, H. S.; Kim, H. K.; Kim, H. T.; Kim, J. H.; Kim, J. C.; Kim, Jong-Su; Kim, Jung-Su; Kim, Kyung-Min; Kim, K. M.; Kim, K. P.; Kim, M. K.; Kim, S. H.; Kim, S. S.; Kim, S. T.; Kim, S. W.; Kim, Y. J.; Kim, Y. K.; Kim, Y. O.; Ko, W. H.; Kogi, Y.; Kong, J. D.; Kubo, S.; Kumazawa, R.; Kwak, S. W.; Kwon, J. M.; Kwon, O. J.; LeConte, M.; Lee, D. G.; Lee, D. K.; Lee, D. R.; Lee, D. S.; Lee, H. J.; Lee, J. H.; Lee, K. D.; Lee, K. S.; Lee, S. G.; Lee, S. H.; Lee, S. I.; Lee, S. M.; Lee, T. G.; Lee, W. C.; Lee, W. L.; Leur, J.; Lim, D. S.; Lohr, J.; Mase, A.; Mueller, D.; Moon, K. M.; Mutoh, T.; Na, Y. S.; Nagayama, Y.; Nam, Y. U.; Namkung, W.; Oh, B. H.; Oh, S. G.; Oh, S. T.; Park, B. H.; Park, D. S.; Park, H.; Park, H. T.; Park, J. K.; Park, J. S.; Park, K. R.; Park, M. K.; Park, S. H.; Park, S. I.; Park, Y. M.; Park, Y. S.; Patterson, B.; Sabbagh, S.; Saito, K.; Sajjad, S.; Sakamoto, K.; Seo, D. C.; Seo, S. H.; Seol, J. C.; Shi, Y.; Song, N. H.; Sun, H. J.; Terzolo, L.; Walker, M.; Wang, S. J.; Watanabe, K.; Welander, A. S.; Woo, H. J.; Woo, I. S.; Yagi, M.; Yaowei, Y.; Yonekawa, Y.; Yoo, K. I.; Yoo, J. W.; Yoon, G. S.; Yoon, S. W.; KSTAR Team
2011-09-01
Since the successful first plasma generation in the middle of 2008, three experimental campaigns were successfully made for the KSTAR device, accompanied with a necessary upgrade in the power supply, heating, wall-conditioning and diagnostic systems. KSTAR was operated with the toroidal magnetic field up to 3.6 T and the circular and shaped plasmas with current up to 700 kA and pulse length of 7 s, have been achieved with limited capacity of PF magnet power supplies. The mission of the KSTAR experimental program is to achieve steady-state operations with high performance plasmas relevant to ITER and future reactors. The first phase (2008-2012) of operation of KSTAR is dedicated to the development of operational capabilities for a super-conducting device with relatively short pulse. Development of start-up scenario for a super-conducting tokamak and the understanding of magnetic field errors on start-up are one of the important issues to be resolved. Some specific operation techniques for a super-conducting device are also developed and tested. The second harmonic pre-ionization with 84 and 110 GHz gyrotrons is an example. Various parameters have been scanned to optimize the pre-ionization. Another example is the ICRF wall conditioning (ICWC), which was routinely applied during the shot to shot interval. The plasma operation window has been extended in terms of plasma beta and stability boundary. The achievement of high confinement mode was made in the last campaign with the first neutral beam injector and good wall conditioning. Plasma control has been applied in shape and position control and now a preliminary kinetic control scheme is being applied including plasma current and density. Advanced control schemes will be developed and tested in future operations including active profiles, heating and current drives and control coil-driven magnetic perturbation.
Study of plasma adrenomedullin level in normal pregnancy and preclampsia.
Senna, Azza Abo; Zedan, Magda; el-Salam, Gamal E Abd; el-Mashad, Ashraf I
2008-02-06
The aim of this study was to evaluate whether maternal circulating adrenomedullin (AM) values in patients with preeclampsia are different from those in normotensive pregnant women at different gestational ages. In a prospective clinical study, 90 women aged 17 to 40 years old, were divided into 4 main groups: group I (45 women): Normotensive pregnant women at first trimester (15 women), second trimester (15 women), and third trimester (15 women) of pregnancies. Group II (15 women): Pregnant women with preeclampsia at 25 to 38 weeks of gestation. Group III (15 women): Normotensive healthy nonpregnant women. Group IV (15 women): Hypertensive nonpregnant women. The plasma AM concentration was measured in all women by using enzyme immunoassay kits. Plasma AM levels in pregnant women with normal blood pressure at different gestational ages (first, second, and third trimesters) were statistically significantly higher than those detected in nonpregnant normotensive women and significantly increased with increasing gestational age (P < .001). Moreover, there was significant positive correlation between plasma AM levels and increasing gestational age (r = 0.915, P < .001). Preeclamptic patients had the highest mean plasma AM levels compared with all other groups, which is statistically significant (P < .001) and there was a significant positive correlation between plasma AM levels and systolic blood pressure, diastolic blood pressure, severity of preeclampsia, and proteinuria in pregnant patients with preeclampsia. Maternal plasma AM concentration increases throughout pregnancy and increases as gestational age progresses. AM production starts very early in gestation, suggesting that it may have an important role in human reproduction, from implantation to delivery. Maternal plasma AM level in preeclampsia appears to be higher than that in normal pregnancy.
Study of Plasma Adrenomedullin Level In Normal Pregnancy and Preclampsia
Senna, Azza Abo; Zedan, Magda; Abd El Salam, Gamal E.; El Mashad, Ashraf I.
2008-01-01
Aim The aim of this study was to evaluate whether maternal circulating adrenomedullin (AM) values in patients with preeclampsia are different from those in normotensive pregnant women at different gestational ages. Subjects and Methods In a prospective clinical study, 90 women aged 17 to 40 years old, were divided into 4 main groups: group I (45 women): Normotensive pregnant women at first trimester (15 women), second trimester (15 women), and third trimester (15 women) of pregnancies. Group II (15 women): Pregnant women with preeclampsia at 25 to 38 weeks of gestation. Group III (15 women): Normotensive healthy nonpregnant women. Group IV (15 women): Hypertensive nonpregnant women. The plasma AM concentration was measured in all women by using enzyme immunoassay kits. Results Plasma AM levels in pregnant women with normal blood pressure at different gestational ages (first, second, and third trimesters) were statistically significantly higher than those detected in nonpregnant normotensive women and significantly increased with increasing gestational age (P < .001). Moreover, there was significant positive correlation between plasma AM levels and increasing gestational age (r = 0.915, P < .001). Preeclamptic patients had the highest mean plasma AM levels compared with all other groups, which is statistically significant (P < .001) and there was a significant positive correlation between plasma AM levels and systolic blood pressure, diastolic blood pressure, severity of preeclampsia, and proteinuria in pregnant patients with preeclampsia. Conclusion Maternal plasma AM concentration increases throughout pregnancy and increases as gestational age progresses. AM production starts very early in gestation, suggesting that it may have an important role in human reproduction, from implantation to delivery. Maternal plasma AM level in preeclampsia appears to be higher than that in normal pregnancy. PMID:18382699
Investigation of cell-free DNA in canine plasma and its relation to disease.
Burnett, Deborah L; Cave, Nicholas J; Gedye, Kristene R; Bridges, Janis P
2016-09-01
DNA is released from dying cells during apoptosis and necrosis. This cell-free DNA (cfDNA) diffuses into the plasma where it can be measured. In humans, an increase in cfDNA correlates with disease severity and prognosis. It was hypothesized that when DNA in canine plasma was measured by emission fluorometry without prior DNA extraction, the concentration of cfDNA would increase with disease severity. The diseased population consisted of 97 client-owned dogs. The clinically normal population consisted of nine client-owned dogs presenting for 'wellness screens', and 15 colony-owned Harrier Hounds. Plasma cfDNA was measured by fluorometry without prior DNA extraction. The effects of ex vivo storage conditions were evaluated in plasma from two clinically normal dogs. In all other dogs, plasma was separated within two hours of collection. The association between the cfDNA concentration in hospitalized dogs and a variety of clinical, clinicopathological and outcome variables was tested. The concentration of cfDNA was reliably measured when plasma was separated within two hours of blood collection. The diseased dogs had significantly higher cfDNA than clinically normal dogs (P < 0.001), and the more severe the disease, the higher the cfDNA when severity was categorized according to the American Society of Anesthesiologists (ASA) status (P < 0.001). Dogs that did not survive to discharge had significantly higher cfDNA concentrations than survivors (P = 0.02). Conclusions/Clinical Importance: The concentration of cfDNA in the plasma of diseased dogs is associated with disease severity and prognosis. Measurement of canine cfDNA could be a useful non-specific disease indicator and prognostic tool.
The ECRH/ECCD system on Tore Supra, a major step towards continuous operation
NASA Astrophysics Data System (ADS)
Lennholm, M.; Agarici, G.; Berger-By, G.; Bosia, P.; Bouquey, F.; Cellier, E.; Clary, J.; Clapit, M.; Darbos, C.; Giruzzi, G.; Jung, M.; Magne, R.; Roux, D.; Segui, J. L.; Traisnel, E.; Zou, X.
2003-11-01
The 118 GHz electron cyclotron heating and current drive (ECRH/ECCD) system under development in Cadarache, France, for use on the Tore Supra tokamak (Pain M. et al 1994 Proc. 18th SOFT (Karlsruhe) pp 481 4: Darbos C. et al 2000 Proc. 21st SOFT (Madrid) pp 605 9), is designed to launch 2.4 MW of power for up to 10 min into the plasma. At present two out of six gyrotrons are installed and available for injection of up to 800 kW. This paper concentrates on the generation and transmission of the ECRH/ECCD power for very long pulse operation. The power is injected into the plasma as Gaussian beams by an antenna which, using actively cooled mirrors inside the Tore Supra vacuum vessel, allows extensive control of both the poloidal and toroidal injection angles. The toroidal field on Tore Supra is normally in the range of 3.8 4 T, which for 118 GHz gives almost central deposition at the fundamental electron cyclotron resonance. A pair of actively cooled corrugated mirrors is installed in each matching optics unit at the output of each gyrotron allowing complete control of the polarization of the wave transmitted to the antenna, with the result that pure O-mode—or pure X-mode—power injection can be achieved for all injection angles. In tokamak experiments, a world record energy of 17.8 MJ has been injected into the plasma. New upgraded gyrotrons specified to produce 400 kW for up to 10 min will be introduced over the next 3 4 years.
Dobrovolskiy, A; Dunets, S; Evsyukov, A; Goncharov, A; Gushenets, V; Litovko, I; Oks, E
2010-02-01
We describe new results of development of novel generation cylindrical plasma devices based on the electrostatic plasma lens configuration and concept of electrons magnetic insulation. The crossed electric and magnetic fields plasma lens configuration provides us with the attractive and suitable method for establishing a stable plasma discharge at low pressure. Using plasma lens configuration in this way some cost-effective plasma devices were developed for ion treatment and deposition of exotic coatings and the effective lens was first proposed for manipulating high-current beams of negatively charged particles. Here we describe operation and features of these plasma devices, and results of theoretical consideration of mechanisms determining their optimal operation conditions.
Modeling of the control of the driven current profile in ICRF MCCD on EAST plasma
NASA Astrophysics Data System (ADS)
Yin, L.; Yang, C.; Gong, X. Y.; Lu, X. Q.; Cao, J. J.; Wu, Z. Y.; Chen, Y.; Du, D.
2018-05-01
Control of the current profile is a crucial issue for improved confinement and the inhibition of instability in advanced tokamak operation. Using typical discharge data for the Experimental Advanced Superconducting Tokamak, numerical simulations of driven-current profile control in mode conversion current drive (MCCD) in the ion cyclotron range of frequencies were performed employing a full-wave method and Ehst-Karney efficiency formula. Results indicate that the driven current profile in MCCD can be effectively modified by shifting the mode conversion layer. The peak of the driven current can be located at an aimed position in the normalized minor radius range (-0.60 ≤r/a≤0) by changing the radiofrequency and the minority-ion concentration. The efficiency of the off-axis MCCD can reach 233 kA/MW through optimization, and the mode converted ion cyclotron wave plays an important role in such scenarios. The effects of electron temperature and plasma density on the driven current profile are also investigated.
Plasma urocortin in human systolic heart failure.
Ng, Leong L; Loke, Ian W; O'Brien, Russell J; Squire, Iain B; Davies, Joan E
2004-04-01
Urocortin (UCN), a member of the corticotrophin-releasing factor family, is expressed in heart, brain and gut. UCN has potent cardiostimulatory, cardioprotective, vasodilator and diuretic/natriuretic effects, and cardiac UCN expression is increased in heart failure (HF). In the present study, we investigated plasma levels of UCN in 119 patients with HF and 212 age- and gender-matched controls to clarify its relationship with gender and disease severity. UCN was elevated in HF [normal males, 19.5 (3.9-68.8) pmol/l and HF males, 50.2 (6.9-108.2) pmol/l, P < 0.0005; normal females, 14.2 (3.9-53.5) pmol/l and HF females, 21.8 (3.9-112.5) pmol/l, P < 0.001; values are medians (range)]. The relative increase was greater in males than females ( P < 0.03). UCN fell with increasing age, especially in HF patients ( r(s) = -0.56, P < 0.0005) and with increasing New York Heart Association (NYHA) class ( r(s) = -0.55, P < 0.0005). The fall in UCN levels with increasing NYHA class was reinforced by a significant correlation between UCN and ejection fraction ( r(s) = 0.45, P < 0.0005) in HF patients. Although receiver operating characteristic (ROC) curves for diagnosis of all HF cases yielded an area under the curve (AUC) of 0.76, ROC AUCs for patients with early HF (NYHA class I and II) were better (0.91). ROC AUCs for logistic models incorporating N-terminal probrain natriuretic peptide (N-BNP) and UCN were better than either peptide alone. In conclusion, plasma UCN is elevated in HF, especially in its early stages. Its decline with increasing HF severity may expedite disease progression due to diminished cardioprotective/anti-inflammatory effects. UCN measurement may also complement N-BNP in the diagnosis of early HF.
A gyrokinetic collision operator for magnetized Lorentz plasmas
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu Chang; Ma Chenhao; Yu Xiongjie
2011-03-15
A gyrocenter collision operator for magnetized Lorentz plasmas is derived using the Fokker-Plank method. The gyrocenter collision operator consists of drift and diffusion terms in the gyrocenter coordinates, including the diffusion of the gyrocenter, which does not exist for the collision operator in the particle phase space coordinates. The gyrocenter collision operator also depends on the transverse electric field explicitly, which is crucial for the correct treatment of collisional effects and transport in the gyrocenter coordinates. The gyrocenter collision operator derived is applied to calculate the particle and heat transport fluxes in a magnetized Lorentz plasma with an electric field.more » The particle and heat transport fluxes calculated from our gyrocenter collision operator agree exactly with the classical Braginskii's result [S. I. Braginskii, Reviews of Plasma Physics (Consultants Bureau, New York, 1965), Vol. 1, p. 205: P. Helander and D. J. Sigmar, Collisional Transport in Magnetized Plasmas (Cambridge University, Cambridge, 2002), p. 65], which validates the correctness of our collision operator. To calculate the transport fluxes correctly, it is necessary to apply the pullback transformation associated with gyrocenter coordinate transformation in the presence of collisions, which also serves as a practical algorithm for evaluating collisional particle and heat transport fluxes in the gyrocenter coordinates.« less
Cortisol as a Biomarker of Stress in Term Human Labor: Physiological and Methodological Issues
Newton, Edward R.; Tanner, Charles J.; Heitkemper, Margaret M.
2013-01-01
Literature on the use of plasma cortisol to quantify psychophysiological stress in humans is extensive. However, in parturition at term gestation the use of cortisol as a biomarker of stress is particularly complex. Plasma cortisol levels increase as labor progresses. This increase seems to be important for maintenance of maternal/fetal wellbeing and facilitation of normal labor progress. Unique physiological and methodological issues involved in the use of cortisol as a biomarker of stress in labor present challenges for researchers. This review examines these issues, suggests mixed methods and within-subject repeated measures designs, and offers recommendations for assay procedures for parturient sampling. Documentation of clinical interventions and delivery outcomes may elucidate relationships among psychophysiological stressors, cortisol and normal labor progress. With attention to these methodological issues, analysis of plasma cortisol may lead to clinical interventions that support normal labor physiology. PMID:23338011
Hung, T-H; Chen, S-F; Lo, L-M; Li, M-J; Yeh, Y-L; Hsieh, T-T
2012-04-01
Myeloperoxidase (MPO) is a heme protein produced and released by activated neutrophils and monocytes, and increased MPO is considered important in the pathophysiology of cardiovascular diseases (CVD). Accumulating evidence suggests that preeclampsia (PE), idiopathic intrauterine growth restriction (IUGR), and CVD share many similar metabolic disturbances, including an enhanced systemic inflammatory response and endothelial dysfunction. We hypothesized that MPO plays an important role in the development of PE and IUGR. Plasma samples were collected mid-gestation and at delivery from women with normal pregnancies (n = 40) and those who subsequently developed PE (n = 20), IUGR (n = 11) or both (PE + IUGR, n = 8). Placental samples were obtained immediately after delivery from 22 women with normal pregnancies, 19 women with PE, 14 women with IUGR, and 14 women with PE + IUGR. The MPO concentrations were measured using ELISA. Women with PE + IUGR had significantly higher plasma MPO before delivery than normal pregnant women. There was no difference in plasma levels at mid-gestation or the placental concentrations between women with normal pregnancies and those who developed PE, IUGR, or PE + IUGR. Using explants prepared from the placentas of 8 women with normal pregnancies and 8 women with PE, we found no difference in the levels of MPO in the tissue homogenates and culture media between these two groups of women. Together, these results indicate that increased maternal circulating MPO in women with PE + IUGR is likely a result of enhanced systemic inflammation caused by the established disease rather than a primary pathophysiological factor. Copyright © 2012 Elsevier Ltd. All rights reserved.
Consensus guidelines on plasma cell myeloma minimal residual disease analysis and reporting.
Arroz, Maria; Came, Neil; Lin, Pei; Chen, Weina; Yuan, Constance; Lagoo, Anand; Monreal, Mariela; de Tute, Ruth; Vergilio, Jo-Anne; Rawstron, Andy C; Paiva, Bruno
2016-01-01
Major heterogeneity between laboratories in flow cytometry (FC) minimal residual disease (MRD) testing in multiple myeloma (MM) must be overcome. Cytometry societies such as the International Clinical Cytometry Society and the European Society for Clinical Cell Analysis recognize a strong need to establish minimally acceptable requirements and recommendations to perform such complex testing. A group of 11 flow cytometrists currently performing FC testing in MM using different instrumentation, panel designs (≥ 6-color) and analysis software compared the procedures between their respective laboratories and reviewed the literature to propose a consensus guideline on flow-MRD analysis and reporting in MM. Consensus guidelines support i) the use of minimum of five initial gating parameters (CD38, CD138, CD45, forward, and sideward light scatter) within the same aliquot for accurate identification of the total plasma cell compartment; ii) the analysis of potentially aberrant phenotypic markers and to report the antigen expression pattern on neoplastic plasma cells as being reduced, normal or increased, when compared to a normal reference plasma cell immunophenotype (obtained using the same instrument and parameters); and iii) the percentage of total bone marrow plasma cells plus the percentages of both normal and neoplastic plasma cells within the total bone marrow plasma cell compartment, and over total bone marrow cells. Consensus guidelines on minimal current and future MRD analyses should target a lower limit of detection of 0.001%, and ideally a limit of quantification of 0.001%, which requires at least 3 × 10(6) and 5 × 10(6) bone marrow cells to be measured, respectively. © 2015 International Clinical Cytometry Society.
Gorsline, J.; Holmes, W.N.
1981-01-01
Unstressed mallard ducks (Anas platyrhychos), given uncontaminated food and maintained on a short photoperiod, show two daily maxima in plasma corticosterone concentration ([B]); one occurring early in the light phase and a second just before the onset of darkness. After one week of exposure to food containing 3% (v/w) South Louisiana crude oil, plasma [B] were significantly lowered throughout the day. Similar abrupt declines in plasma [B] also occurred during the first 10 days of exposure to food containing 1% and 0.5% crude oil. Although the plasma [B] in birds consuming food contaminated with 0.5% crude oil increased between 10 and 50 days of exposure, the concentration after 50 days was still lower than normal. During the same interval, normal plasma [B] were restored in birds consuming food containing 1% and 3% crude oil. Significant increases occurred in the naphthalene-metabolizing properties of hepatic microsomes prepared from birds acutely exposed to all levels of petroleum-contaminated food and elevated levels were sustained throughout the first 50 days of exposure. Birds given food containing 3% crude oil for more than 50 days, however, showed steady declines in hepatic naphthalene-metabolizing activity. After 500 days, the activity was similar to that found in contemporaneous controls. During the same interval, the plasma [B] increased until the levels were higher than normal after 500 days of exposure; at this time, an inverse relationship, similar to that seen during the first week of exposure to contaminated food, was once more established between plasma [B] and the concomitant hepatic naphthalene-metabolizing activity.
Naito, Takafumi; Kubono, Naoko; Ishida, Takuya; Deguchi, Shuhei; Sugihara, Masahisa; Itoh, Hiroaki; Kanayama, Naohiro; Kawakami, Junichi
2015-12-01
This study aimed to evaluate plasma 4β-hydroxycholesterol as an endogenous marker of CYP3A4/5 activity in early postpartum women and its impact on the plasma disposition of amlodipine. Twenty-seven early postpartum women treated with amlodipine for pregnancy-induced hypertension were enrolled. The plasma concentration of 4β-hydroxycholesterol and its ratio to cholesterol in postpartum and in non-perinatal women were evaluated. The predose plasma concentration of amlodipine was determined at steady state. The medians of the plasma 4β-hydroxycholesterol concentration at day 0-3 and 8-21 after delivery were 146 and 161 ng/mL, respectively. No significant difference was observed in the plasma concentration of 4β-hydroxycholesterol between the postpartum periods. The plasma concentration of 4β-hydroxycholesterol and its ratio to cholesterol in postpartum women were significantly higher than those in non-perinatal women. A large individual variability was observed in the dose-normalized plasma concentration of amlodipine in early postpartum women. A weak negative correlation was observed between the dose-normalized plasma concentration of amlodipine and the plasma concentration of 4β-hydroxycholesterol. In conclusion, early postpartum women possessed higher CYP3A activity based on plasma 4β-hydroxycholesterol and had a large pharmacokinetic variability in amlodipine. CYP3A activity during the early postpartum period had an effect on the plasma disposition of amlodipine. Copyright © 2015 The Japanese Society for the Study of Xenobiotics. Published by Elsevier Ltd. All rights reserved.
Arruda, Jose A. L.; Nascimento, Luiz; Mehta, Pradeep K.; Rademacher, Donald R.; Sehy, John T.; Westenfelder, Christof; Kurtzman, Neil A.
1977-01-01
Measurement of urine to blood (U-B) carbon dioxide tension (PCO2) gradient during alkalinization of the urine has been suggested to assess distal H+ secretion. A fact that has not been considered in previous studies dealing with urinary PCO2 is that dissolution of HCO3 in water results in elevation of PCO2 which is directly proportional to the HCO3 concentration. To investigate the interrelationship of urinary HCO3 and urinary acidification, we measured U-B PCO2 in (a) the presence of enhanced H+ secretion and decreased concentrating ability i.e., chronic renal failure (CRF), (b) animals with normal H+ secretion and decreased concentrating ability, Brattleboro (BB) rats, and (c) the presence of both impaired H+ secretion and concentrating ability (LiCl treatment and after release of unilateral ureteral obstruction). At moderately elevated plasma HCO3 levels (30-40 meq/liter), normal rats achieved a highly alkaline urine (urine pH > 7.8) and raised urine HCO3 concentration and U-B PCO2. At similar plasma HCO3 levels, BB rats had a much higher fractional water excretion and failed to raise urine pH, urine HCO3 concentration, and U-B PCO2 normally. At a very high plasma HCO3 (>50 meq/liter), BB rats raised urine pH, urine HCO3 concentration, and U-B PCO2 to the same levels seen in normals. CRF rats failed to raise urine pH, urine HCO3, and U-B PCO2 normally at moderately elevated plasma HCO3 levels; at very high plasma HCO3 levels, CRF rats achieved a highly alkaline urine but failed to raise U-B PCO2. Dogs and patients with CRF were also unable to raise urine pH, urine HCO3 concentration, and U-B PCO2 normally at moderately elevated plasma HCO3 levels. In rats, dogs, and man, U-B PCO2 was directly related to urine HCO3 concentration and inversely related to fractional water excretion. At moderately elevated plasma HCO3 levels, animals with a distal acidification defect failed to raise U-B PCO2; increasing the plasma HCO3 to very high levels resulted in a significant increase in urine HCO3 concentration and U-B PCO2. The observed urinary PCO2 was very close to the PCO2 which would be expected by simple dissolution of a comparable amount of HCO3 in water. These data demonstrate that, in highly alkaline urine, urinary PCO2 is largely determined by concentration of urinary HCO3 and cannot be used as solely indicating distal H+ secretion. PMID:893680
CORSICA modelling of ITER hybrid operation scenarios
NASA Astrophysics Data System (ADS)
Kim, S. H.; Bulmer, R. H.; Campbell, D. J.; Casper, T. A.; LoDestro, L. L.; Meyer, W. H.; Pearlstein, L. D.; Snipes, J. A.
2016-12-01
The hybrid operating mode observed in several tokamaks is characterized by further enhancement over the high plasma confinement (H-mode) associated with reduced magneto-hydro-dynamic (MHD) instabilities linked to a stationary flat safety factor (q ) profile in the core region. The proposed ITER hybrid operation is currently aiming at operating for a long burn duration (>1000 s) with a moderate fusion power multiplication factor, Q , of at least 5. This paper presents candidate ITER hybrid operation scenarios developed using a free-boundary transport modelling code, CORSICA, taking all relevant physics and engineering constraints into account. The ITER hybrid operation scenarios have been developed by tailoring the 15 MA baseline ITER inductive H-mode scenario. Accessible operation conditions for ITER hybrid operation and achievable range of plasma parameters have been investigated considering uncertainties on the plasma confinement and transport. ITER operation capability for avoiding the poloidal field coil current, field and force limits has been examined by applying different current ramp rates, flat-top plasma currents and densities, and pre-magnetization of the poloidal field coils. Various combinations of heating and current drive (H&CD) schemes have been applied to study several physics issues, such as the plasma current density profile tailoring, enhancement of the plasma energy confinement and fusion power generation. A parameterized edge pedestal model based on EPED1 added to the CORSICA code has been applied to hybrid operation scenarios. Finally, fully self-consistent free-boundary transport simulations have been performed to provide information on the poloidal field coil voltage demands and to study the controllability with the ITER controllers. Extended from Proc. 24th Int. Conf. on Fusion Energy (San Diego, 2012) IT/P1-13.
Intense steady state electron beam generator
Hershcovitch, A.; Kovarik, V.J.; Prelec, K.
1990-07-17
An intense, steady state, low emittance electron beam generator is formed by operating a hollow cathode discharge plasma source at critical levels in combination with an extraction electrode and a target electrode that are operable to extract a beam of fast primary electrons from the plasma source through a negatively biased grid that is critically operated to repel bulk electrons toward the plasma source while allowing the fast primary electrons to move toward the target in the desired beam that can be successfully transported for relatively large distances, such as one or more meters away from the plasma source. 2 figs.
Core plasma design of the compact helical reactor with a consideration of the equipartition effect
NASA Astrophysics Data System (ADS)
Goto, T.; Miyazawa, J.; Yanagi, N.; Tamura, H.; Tanaka, T.; Sakamoto, R.; Suzuki, C.; Seki, R.; Satake, S.; Nunami, M.; Yokoyama, M.; Sagara, A.; the FFHR Design Group
2018-07-01
Integrated physics analysis of plasma operation scenario of the compact helical reactor FFHR-c1 has been conducted. The DPE method, which predicts radial profiles in a reactor by direct extrapolation from the reference experimental data, has been extended to implement the equipartition effect. Close investigation of the plasma operation regime has been conducted and a candidate plasma operation point of FFHR-c1 has been identified within the parameter regime that has already been confirmed in LHD experiment in view of MHD equilibrium, MHD stability and neoclassical transport.
A unique control system simulator for the evaluation of pulsed plasma thrusters
NASA Technical Reports Server (NTRS)
Dahlgren, J. B.
1973-01-01
Because of the low thrust characteristics of solid-propellant pulsed plasma thrusters and their operational requirement to operate in a vacuum environment, unique and sensitive test techniques are required. A technique evolved for testing and evaluating pulsed plasma thrusters in an open- or closed-loop system mode employs a unique air bearing platform as a single-axis simulator on which the thruster is mounted. The simulator described was developed to evaluate pulsed plasma thrusters in the low micropound range; however, the simulator can be extended to cover the operational range of currently developed millipound thrusters.
Intense steady state electron beam generator
Hershcovitch, Ady; Kovarik, Vincent J.; Prelec, Krsto
1990-01-01
An intense, steady state, low emittance electron beam generator is formed by operating a hollow cathode discharge plasma source at critical levels in combination with an extraction electrode and a target electrode that are operable to extract a beam of fast primary electrons from the plasma source through a negatively biased grid that is critically operated to repel bulk electrons toward the plasma source while allowing the fast primary electrons to move toward the target in the desired beam that can be successfully transported for relatively large distances, such as one or more meters away from the plasma source.
NASA Astrophysics Data System (ADS)
Styrnoll, T.; Bienholz, S.; Lapke, M.; Awakowicz, P.
2014-04-01
This paper discusses plasma probe diagnostics, namely the multipole resonance probe (MRP) and Langmuir probe (LP), operated in depositing plasmas. The aim of this work is to show that the combination of both probes provides stable and robust measurements and clear determination of plasma parameters for metallic and ceramic coating processes. The probes use different approaches to determine plasma parameters, e.g. electron density ne and electron temperature Te. The LP is a well-established plasma diagnostic, and its applicability in technological plasmas is well documented. The LP is a dc probe that performs a voltage sweep and analyses the measured current, which makes it insensitive against conductive metallic coating. However, once the LP is dielectrically coated with a ceramic film, its functionality is constricted. In contrast, the MRP was recently presented as a monitoring tool, which is insensitive to coating with dielectric ceramics. It is a new plasma diagnostic based on the concept of active plasma resonance spectroscopy, which uses the universal characteristic of all plasmas to resonate on or near the electron plasma frequency. The MRP emits a frequency sweep and the absorption of the signal, the |S11| parameter, is analysed. Since the MRP concept is based on electromagnetic waves, which are able to transmit dielectrics, it is insensitive to dielectric coatings. But once the MRP is metallized with a thin conductive film, no undisturbed RF-signal can be emitted into the plasma, which leads to falsified plasma parameter. In order to compare both systems, during metallic or dielectric coating, the probes are operated in a magnetron CCP, which is equipped with a titanium target. We present measurements in metallic and dielectric coating processes with both probes and elaborate advantages and problems of each probe operated in each coating environment.
Tsang, V C; Wyatt, C R; Damian, R T
1979-06-01
The functional capabilities of a thermometric clot-timer have been demonstrated in a comparative study of human and mouse plasma coagulation. The influence of some variables on coagulation times of mouse and human plasmas were examined in activated partial thromboplastin time, one-stage prothrombin time, and Russell's viper venom time assays. Mouse plasma coagulation times were generally shorter and more reproducible than those of human plasma. Optimal assay conditions are also described.
Saunders, J P; Donner, T W; Sadler, J H; Levin, G V; Makris, N G
1999-04-01
D-tagatose, a stereoisomer of D-fructose, is a naturally occurring ketohexose proposed for use as a low-calorie bulk sweetener. Ingested D-tagatose appears to be poorly absorbed. The absorbed portion is metabolized in the liver by a pathway similar to that of D-fructose. The main purpose of this study was to determine if acute or repeated oral doses of D-tagatose would cause elevations in plasma uric acid (as is seen with fructose) in normal humans and Type 2 diabetics. In addition, effects of subchronic D-tagatose ingestion on fasting plasma phosphorus, magnesium, lipids, and glucose homeostasis were studied. Eight normal subjects and eight subjects with Type 2 diabetes participated in this two-phase study. Each group was comprised of four males and four females. In the first phase, all subjects were given separate 75 g 3-h oral glucose and D-tagatose tolerance tests. Uric acid, phosphorus, and magnesium were determined in blood samples collected from each subject at 0, 30, 60, 120, and 180 min after dose. In the 8-week phase of the study, the normals were randomly placed into two groups which received 75 g of either D-tagatose or sucrose (25 g with each meal) daily for 8 weeks. The diabetics were randomized into two groups which received either 75 g D-tagatose or no supplements of sugar daily for 8 weeks. Uric acid, phosphorus, magnesium, lipids, glycosylated hemoglobin, glucose, and insulin were determined in fasting blood plasma of all subjects at baseline (time zero) and biweekly over the 8 weeks. The 8-week test did not demonstrate an increase in fasting plasma uric acid in response to the daily intake of D-tagatose. However, a transient increase of plasma uric acid levels was observed after single doses of 75 g of D-tagatose in the tolerance test. Plasma uric acid levels were found to rise and peak at 60 min after such dosing. No clinical relevance was attributed to this treatment-related effect because excursions of plasma uric acid levels above the normal range were small and were of short duration. Consistent with earlier observations on fructose, the increase of plasma uric acid was associated with a slight decrease of plasma phosphorus and a slight increase of magnesium. The daily ingestion of D-tagatose for 8 weeks had no effect on fasting plasma magnesium, phosphorus, cholesterol, triglycerides, glycosylated hemoglobin, glucose, and insulin levels. The ingestion of three 25-g doses per day for a period of 8 weeks resulted in varying amounts of flatulence in seven of the eight subjects, and some degree of diarrhea in six subjects. D-tagatose holds promise as a sweetener with no adverse clinical effects observed in these studies. Copyright 1999 Academic Press.
2012-01-01
Background It is well known that somatotrophic/insulin signaling affects lifespan in experimental animals, and one of the signs of aging is progressive gonadal dysfunction. Methods To study the effects of insulin-like growth factor-1 (IGF-1) plasma level on ovaries, we analyzed ovaries isolated from 2-year-old growth hormone receptor knockout (GHR-KO) Laron dwarf mice, with low circulating plasma levels of IGF-1, and 6-month-old bovine growth hormone transgenic (bGHTg) mice, with high circulating plasma levels of IGF-1. The ages of the Laron dwarf mutants employed in our studies were selected based on their overall survival (up to ~ 4 years for Laron dwarf mice and ~ 1 year for bGHTg mice). Results Morphological analysis of the ovaries of mice that reached ~50% of their maximal life span revealed a lower biological age for the ovaries isolated from 2-year-old Laron dwarf mice than their normal-lifespan wild type littermates. By contrast, the ovarian morphology of increased in size 6 month old bGHTg mice was generally normal. Conclusion Ovaries isolated from 2-year-old Laron dwarf mice exhibit a lower biological age compared with ovaries from normal WT littermates at the same age. At the same time, no morphological features of accelerated aging were found in 0.5-year-old bGHTg mice compared with ovaries from normal the same age-matched WT littermates. PMID:22747742
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kiriyama, Ryutaro; Takenaka, Tomoya; Kurisu, Yousuke
2012-02-15
We measure the ion beam current and the plasma parameters by using the pulse mode microwave operation in the first stage of a tandem type ECRIS. The time averaged extracted ion beam current in the pulse mode operation is larger than that of the cw mode operation with the same averaged microwave power. The electron density n{sub e} in the pulse mode is higher and the electron temperature T{sub e} is lower than those of the cw mode operation. These plasma parameters are considered to cause in the increase of the ion beam current and are suitable to produce molecularmore » or cluster ions.« less
Comparison of hypertonic saline versus normal saline on cytokine profile during CABG
2012-01-01
Background and the purpose of the study Blood contact with artificial surfaces of the extracorporeal circuit and ischemia-reperfusion injury in CABG with CPB, may lead to a systemic inflammatory response. Hypertonic saline have been recently investigated as a fluid in order to decrease inflammatory response and cytokines generation in patients undergo cardiac operations. Our purpose is to study the prophylactic effect of HS 5% infusion versus NS on serum IL-6 as an inflammatory & IL-10 as an anti-inflammatory biomarker in CABG patients. Methods The present study is a randomized double-blinded clinical trial. 40 patients undergoing CABG were randomized to receive HS 5% or NS before operation. Blood samples were obtained after receiving HS or NS, just before operation, 24 and 48 hours post-operatively. Plasma levels of IL-6 and IL-10 were measured by ELISA. Results and major conclusion Patients received HS had lower levels of IL-6 and higher level of IL-10 compared with NS group, however these differences were not statistically significant. Results of this study suggest that pre-treatment with small volume hypertonic saline 5% may have beneficial effects on inflammatory response following CABG operation. PMID:23351427
Takahashi, K; Inoue, K; Takahashi, Y
1976-10-01
Twenty-four-hr patterns of plasma corticosterone levels were determined at 4-hr intervals every 3-4 weeks in sighted and blinded pinealectomized rats of adult age. Through the whole period of the experiment, 24-hr patterns of food intake were also measured weekly. The sighted rats manifested the same 24-hr patterns of plasma corticosterone levels and food intake for 15 weeks after pinealectomy as those observed in the intact control rats. The magnitude of peak levels of plasma corticosterone and the amount of food intake did not differ between the two groups. A phase shift in circadian rhythms of plasma corticosterone levels and food intake was observed in both groups of blinded rats, with and without pinealectomy. Between the two groups, the patterns of phase shift were essentially similar for 10 weeks examined after optic enucleation. The peak elevation of plasma levels took place at 11 p.m. at the end of the 4th week after optic enucleation. Thereafter, 4- to 8-hr delay of peak appearance was observed every 3 weeks. No significant differences were found in peak values between the two groups of blinded rats. Furthermore, the circadian rhythm of food intake shifted in parallel with that of plasma corticosterone levels. A phase reversal of these two activities was observed between the 8th and 10th week after the operation. These results indicate that the pineal gland does not play any important role either in the maintenance of normal circadian periodicities of adrenocortical activity and food intake or in the shift in circadian rhythms of the two activities in the blinded rats.
Bulk ion heating with ICRF waves in tokamaks
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mantsinen, M. J., E-mail: mervi.mantsinen@bsc.es; Barcelona Supercomputing Center, Barcelona; Bilato, R.
2015-12-10
Heating with ICRF waves is a well-established method on present-day tokamaks and one of the heating systems foreseen for ITER. However, further work is still needed to test and optimize its performance in fusion devices with metallic high-Z plasma facing components (PFCs) in preparation of ITER and DEMO operation. This is of particular importance for the bulk ion heating capabilities of ICRF waves. Efficient bulk ion heating with the standard ITER ICRF scheme, i.e. the second harmonic heating of tritium with or without {sup 3}He minority, was demonstrated in experiments carried out in deuterium-tritium plasmas on JET and TFTR andmore » is confirmed by ICRF modelling. This paper focuses on recent experiments with {sup 3}He minority heating for bulk ion heating on the ASDEX Upgrade (AUG) tokamak with ITER-relevant all-tungsten PFCs. An increase of 80% in the central ion temperature T{sub i} from 3 to 5.5 keV was achieved when 3 MW of ICRF power tuned to the central {sup 3}He ion cyclotron resonance was added to 4.5 MW of deuterium NBI. The radial gradient of the T{sub i} profile reached locally values up to about 50 keV/m and the normalized logarithmic ion temperature gradients R/LT{sub i} of about 20, which are unusually large for AUG plasmas. The large changes in the T{sub i} profiles were accompanied by significant changes in measured plasma toroidal rotation, plasma impurity profiles and MHD activity, which indicate concomitant changes in plasma properties with the application of ICRF waves. When the {sup 3}He concentration was increased above the optimum range for bulk ion heating, a weaker peaking of the ion temperature profile was observed, in line with theoretical expectations.« less
Poulin, Patrick; Hop, Cornelis Eca; Salphati, Laurent; Liederer, Bianca M
2013-04-01
Understanding drug distribution and accumulation in tumors would be informative in the assessment of efficacy in targeted therapy; however, existing methods for predicting tissue drug distribution focus on normal tissues and do not incorporate tumors. The main objective of this study was to describe the relationships between tissue-plasma concentration ratios (Kp ) of normal tissues and those of subcutaneous xenograft tumors under nonsteady-state conditions, and establish regression equations that could potentially be used for the prediction of drug levels in several human tumor xenografts in mouse, based solely on a Kp value determined in a normal tissue (e.g., muscle). A dataset of 17 compounds was collected from the literature and from Genentech. Tissue and plasma concentration data in mouse were obtained following oral gavage or intraperitoneal administration. Linear regression analyses were performed between Kp values in several normal tissues (muscle, lung, liver, or brain) and those in human tumor xenografts (CL6, EBC-1, HT-29, PC3, U-87, MCF-7-neo-Her2, or BT474M1.1). The tissue-plasma ratios in normal tissues reasonably correlated with the tumor-plasma ratios in CL6, EBC-1, HT-29, U-87, BT474M1.1, and MCF-7-neo-Her2 xenografts (r(2) in the range 0.62-1) but not with the PC3 xenograft. In general, muscle and lung exhibited the strongest correlation with tumor xenografts, followed by liver. Regression coefficients from brain were low, except between brain and the glioblastoma U-87 xenograft (r(2) in the range 0.62-0.94). Furthermore, reasonably strong correlations were observed between muscle and lung and between muscle and liver (r(2) in the range 0.67-0.96). The slopes of the regressions differed depending on the class of drug (strong vs. weak base) and type of tissue (brain vs. other tissues and tumors). Overall, this study will contribute to our understanding of tissue-plasma partition coefficients for tumors and facilitate the use of physiologically based pharmacokinetics (PBPK) modeling for chemotherapy in oncology studies. © 2013 Wiley Periodicals, Inc. and the American Pharmacists Association J Pharm Sci 102:1355-1369, 2013. Copyright © 2013 Wiley Periodicals, Inc.
Effect of Roux-en-Y Gastric Bypass Surgery on Bile Acid Metabolism in Normal and Obese Diabetic Rats
Bhutta, Hina Y; Rajpal, Neetu; White, Wendy; Freudenberg, Johannes M.; Liu, Yaping; Way, James; Rajpal, Deepak; Cooper, David C.; Young, Andrew; Tavakkoli, Ali; Chen, Lihong
2015-01-01
In addition to classic functions of facilitating hepatobiliary secretion and intestinal absorption of lipophilic nutrients, bile acids (BA) are also endocrine factors and regulate glucose and lipid metabolism. Recent data indicate that antiobesity bariatric procedures e.g. Roux-en-Y gastric bypass surgery (RYGB), which also remit diabetes, increase plasma BAs in humans, leading to the hypothesis that BAs may play a role in diabetes resolution following surgery. To investigate the effect of RYGB on BA physiology and its relationship with glucose homeostasis, we undertook RYGB and SHAM surgery in Zucker diabetic fatty (ZDF) and normoglycemic Sprague Dawley (SD) rats and measured plasma and fecal BA levels, as well as plasma glucose, insulin, Glucagon like peptide 1 (GLP-1) and Peptide YY (PYY), 2 days before and 3, 7, 14 and 28 days after surgery. RYGB decreased body weight and increased plasma GLP-1 in both SD and ZDF rats while decreasing plasma insulin and glucose in ZDF rats starting from the first week. Compared to SHAM groups, both SD-RYGB and ZDF-RYGB groups started to have increases in plasma total BAs in the second week, which might not contribute to early post-surgery metabolic changes. While there was no significant difference in fecal BA excretion between SD-RYGB and SD-SHAM groups, the ZDF-RYGB group had a transient 4.2-fold increase (P<0.001) in 24-hour fecal BA excretion on post-operative day 3 compared to ZDF-SHAM, which paralleled a significant increase in plasma PYY. Ratios of plasma and fecal cholic acid/chenodeoxycholic acid derived BAs were decreased in RYGB groups. In addition, tissue mRNA expression analysis suggested early intestinal BA reabsorption and potentially reduced hepatic cholic acid production in RYGB groups. In summary, we present novel data on RYGB-mediated changes in BA metabolism to further understand the role of BAs in RYGB-induced metabolic effects in humans. PMID:25798945
Exposure to triaryl phosphates: metabolism and biomarkers of exposure
Furlong, Clement E.
2013-01-01
The leakage of tricresyl phosphate-containing engine lubricants into aircraft cabin air, either from worn or defective engine seals or under normal operating conditions, is a serious concern for both the health and safety of the cabin occupants, since the oil contains one to five percent tricresyl phosphate (TCP) esters, known neurotoxins. The exposure of pilots is a particular concern since their impairment can affect their safe operation of the aircraft. Mass spectrometric (MS)-based protocols for documenting exposures of individuals are described that entail a rapid purification of the TCP-modified plasma enzyme butyrylcholinesterase (BChE). Following protease digestion of BChE, the modified active site peptide is characterized by MS analysis. Approaches for identifying safer engine oil additives are also described. Some general comments regarding the necessity of improving the quality and safety of the cabin air supply are presented. PMID:24285929
DOE Office of Scientific and Technical Information (OSTI.GOV)
McKenzie-Carter, M.A.; Lyon, R.E.
This report contains information to support the Environmental Assessment for the Compact Ignition Tokamak Project (CIT) proposed for Princeton Plasma Physics Laboratory (PPPL). The assumptions and methodology used to assess the impact to members of the public from operational and accidental releases of radioactive material from the proposed CIT during the operational period of the project are described. A description of the tracer release tests conducted at PPPL by NOAA is included; dispersion values from these tests are used in the dose calculation. Radiological releases, doses, and resulting health risks are calculated. The computer code AIRDOS-EPA is used to calculatemore » the individual and population doses for routine releases; FUSCRAC3 is used to calculate doses resulting from off-normal releases where direct application of the NOAA tracer test data is not practical. Where applicable, doses are compared to regulatory limits and guidelines values. 44 refs., 5 figs., 18 tabs.« less
Tunable angle absorption of hyperbolic metamaterials based on plasma photonic crystals
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jiao, Zheng; Ning, Renxia, E-mail: nrxxiner@hsu.edu.cn; Xu, Yuan
2016-06-15
We present the design of a multilayer structure of hyperbolic metamaterials based on plasma photonic crystals which composed of two kinds of traditional dielectric and plasma. The relative permittivity of hyperbolic metamaterials has been studied at certain frequency range. The absorption and reflection of the multilayer period structure at normal and oblique incident have been investigated by the transfer matrix method. We discussed that the absorption is affected by the thickness of material and the electron collision frequency γ of the plasma. The results show that an absorption band at the low frequency can be obtained at normal incident anglemore » and another absorption band at the high frequency can be found at a large incident angle. The results may be applied by logical gate, stealth, tunable angle absorber, and large angle filter.« less
Hanew, K; Tanaka, A; Utsumi, A
1998-02-01
To investigate GH secretory capacities in patients with Turner's syndrome, GHRH, arginine, L-dopa and pyridostigmine (PD) were administered singly and GHRH was administered sequentially for 3 days. In addition, plasma GH and TSH responses to GHRH and TRH after pretreatment with PD were analyzed to investigate whether the hypothalamic cholinergic somatostatinergic system functioned normally. The maximal GH responses to GHRH, L-dopa and PD were significantly smaller in Turner's syndrome (no.=14) than in normal short children (NSC, no.=14). However, there was no difference in plasma GH responses to arginine between the two groups. In ten patients with Turner's syndrome, the plasma GH response to GHRH did not improve even after the sequential 3-day administrations. Although plasma GH and TSH responses to GHRH and TRH were significantly enhanced by the pretreatment of PD in NSC (no.=12), these responses were not enhanced in Turner's syndrome. Plasma GH response to GHRH in Turner's syndrome with normal body fat was still significantly lower than in NSC. It is therefore concluded that somatotroph sensitivity to GHRH is decreased in Turner's syndrome and that this may be due to the primary defects of the somatotrophs rather than to the increased body fat. In addition, the network of cholinergic-somatostatinergic systems seemed to be impaired in these patients, while the activity of hypothalamic somatostatin neurons was thought to be maintained.
Trabado, Séverine; Al-Salameh, Abdallah; Croixmarie, Vincent; Masson, Perrine; Corruble, Emmanuelle; Fève, Bruno; Colle, Romain; Ripoll, Laurent; Walther, Bernard; Boursier-Neyret, Claire; Werner, Erwan; Becquemont, Laurent; Chanson, Philippe
2017-01-01
Metabolomic approaches are increasingly used to identify new disease biomarkers, yet normal values of many plasma metabolites remain poorly defined. The aim of this study was to define the "normal" metabolome in healthy volunteers. We included 800 French volunteers aged between 18 and 86, equally distributed according to sex, free of any medication and considered healthy on the basis of their medical history, clinical examination and standard laboratory tests. We quantified 185 plasma metabolites, including amino acids, biogenic amines, acylcarnitines, phosphatidylcholines, sphingomyelins and hexose, using tandem mass spectrometry with the Biocrates AbsoluteIDQ p180 kit. Principal components analysis was applied to identify the main factors responsible for metabolome variability and orthogonal projection to latent structures analysis was employed to confirm the observed patterns and identify pattern-related metabolites. We established a plasma metabolite reference dataset for 144/185 metabolites. Total blood cholesterol, gender and age were identified as the principal factors explaining metabolome variability. High total blood cholesterol levels were associated with higher plasma sphingomyelins and phosphatidylcholines concentrations. Compared to women, men had higher concentrations of creatinine, branched-chain amino acids and lysophosphatidylcholines, and lower concentrations of sphingomyelins and phosphatidylcholines. Elderly healthy subjects had higher sphingomyelins and phosphatidylcholines plasma levels than young subjects. We established reference human metabolome values in a large and well-defined population of French healthy volunteers. This study provides an essential baseline for defining the "normal" metabolome and its main sources of variation.
Fairfax, A J; Rehahn, M; Jones, D; O'Malley, B
1984-01-01
The time course of changes in plasma cyclic AMP, heart rate and bronchial tone after inhalation of fenoterol or isoprenaline from a dose-metered aerosol are reported in a group of normal subjects. After isoprenaline, plasma cyclic AMP increased rapidly reaching a peak by 10 min and returned to basal levels within 60 min. A rapid, transient rise in heart rate occurred that was maximal by 5 min and returned to a basal level by 45 min. After fenoterol, the changes in cyclic AMP and heart rate were of much longer duration. The rise in plasma cyclic AMP was slower in onset and of greater magnitude than for isoprenaline, reaching a peak by 20 min and remaining above basal level for more than 6 h. The maximum increase in heart rate after fenoterol was less than that observed with isoprenaline but an elevated rate persisted for 4 h after inhalation of fenoterol. Fenoterol is known to have a longer duration of action as a bronchodilator in comparison with isoprenaline. The prolonged rise in plasma cyclic AMP in normal subjects given inhaled fenoterol may reflect this long duration of action. The concomitant rise in heart rate, however, suggests that the duration of plasma cyclic AMP response may in part be due to the systemic effect of the fraction of inhaled fenoterol known to be absorbed via the buccal and intestinal routes. PMID:6322828
NASA Astrophysics Data System (ADS)
Tormoen, Garth W.; Khader, Ayesha; Gruber, András; McCarty, Owen J. T.
2013-06-01
Thrombosis significantly contributes to cancer morbidity and mortality. The mechanism behind thrombosis in cancer may be circulating tissue factor (TF), as levels of circulating TF are associated with thrombosis. However, circulating TF antigen level alone has failed to predict thrombosis in patients with cancer. We hypothesize that coagulation factor levels regulate the kinetics of circulating TF-induced thrombosis. Coagulation kinetics were measured as a function of individual coagulation factor levels and TF particle concentration. Clotting times increased when pooled plasma was mixed at or above a ratio of 4:6 with PBS. Clotting times increased when pooled plasma was mixed at or above a ratio of 8:2 with factor VII-depleted plasma, 7:3 with factor IX- or factor X-depleted plasmas, or 2:8 with factor II-, V- or VIII-depleted plasmas. Addition of coagulation factors VII, X, IX, V and II to depleted plasmas shortened clotting and enzyme initiation times, and increased enzyme generation rates in a concentration-dependent manner. Only additions of factors IX and X from low-normal to high-normal levels shortened clotting times and increased enzyme generation rates. Our results demonstrate that coagulation kinetics for TF particles are controlled by factor IX and X levels within the normal physiological range. We hypothesize that individual patient factor IX and X levels may be prognostic for susceptibility to circulating TF-induced thrombosis.
The relationship between uric acid and potassium in normal subjects.
Kennedy, A C; Boddy, K; King, P C; Brennan, J; Anderson, J A; Buchanan, W W
1978-01-01
The serum uric acid concentration in normal healthy subjects has been studied in relation to sex, height, weight, lean body mass measured from total body potassium and predicted from the Hume-Weyers formula (1971), total body potassium, plasma potassium and urea, and packed cell volume. The strongest correlation was found with sex, but height, weight, total body potassium, lean body mass (measured and predicted) also correlated significantly with serum uric acid concentration. However, when the sex variable was removed, the other factors lost their significant correlation. Finally, total red blood cell and plasma volumes were predicted (Hume and Goldberg, 1964) and from these an estimate of total plasma uric acid, total plasma potassium, and total red blood cell potassium obtained. Measured total body potassium was found to correlate well with total plasma potassium and total red blood cell potassium independent of sex. Total plasma uric acid correlated well with measured total body potassium when both sexes were considered and when separated into male and female groups the males retained a significant correlation as did the female group. PMID:686865
Plasma trypsin in chronic pancreatitis and pancreatic adenocarcinoma.
Adrian, T E; Besterman, H S; Mallinson, C N; Pera, A; Redshaw, M R; Wood, T P; Bloom, S R
1979-10-01
We have used a simple and precise radioimmunoassay to measure trypsin in human plasma. Fasting plasma trypsin concentrations were extremely low in patients with chronic pancreatitis with steatorrhoea (5 +/- 2 ng/ml) when compared to healthy controls (86 +/- 7 ng/ml, p less than 0.001). In patients with chronic pancreatitis but no steatorrhoea basal plasma trypsin levels were similar to those of the normal controls (99 +/- 25 ng/ml). A small but significant postprandial rise in plasma trypsin concentrations was observed in normal subjects (mean increment 15 +/- 4%, p less than 0.005, paired t test) but was absent in patients with chronic pancreatitis with steatorrhoea. In contrast to exocrine deficient chronic pancreatitis, other malabsorptive conditions associated with steatorrhoea (active coeliac disease and acute tropical sprue) demonstrated mean fasting trypsin concentrations similar to controls. Patients with adenocarcinoma of the pancreas had basal trypsin concentrations similar to healthy subjects as did patients with adenocarcinoma of the stomach, colon, rectum, brochus, and breast. In some cases measurement of plasma trypsin may be of help in the differential diagnosis of steatorrhoea.
Li, Hongqiu; Wang, Zhe; Fu, Qin; Zhang, Jing
2014-11-01
In our study, we detect the levels of three micro-RNAs (miRNAs; miR-21, miR-133a and miR-146a) in the plasma of 120 Chinese postmenopausal women who were divided into three groups (normal, osteopenia and osteoporosis) according to the T-scores. Downregulation of miR-21, as well as upregulation of miR-133a, was validated in the plasma of osteoporosis and osteopenia patients versus the normal group. The difference in expression regarding the miR-146a level in plasma among the three groups was not significant (p > 0.01). The circulating miRNA expression levels and bone mineral density (BMD) were examined during a multiple correlation analysis as a dependent variable after adjusting for age, weight and height. We have demonstrated that specific miRNAs species are significantly changed in the plasma of osteoporosis and osteopenia patients and correlated with the BMD. Our study suggested a potential use of miR-21 and miR-133a as sensitive and plasma biomarkers for postmenopausal osteoporosis.
ECRH launching scenario in FFHR-d1
NASA Astrophysics Data System (ADS)
Yanagihara, Kota; Kubo, Shin; Shimozuma, Takashi; Yoshimura, Yasuo; Igami, Hiroe; Takahashi, Hiromi; Tsujimura, Tohru; Makino, Ryohhei
2016-10-01
ECRH is promising as a principal heating system in a prototype helical reactor FFHR-d1 where the heating power of 80 MW is required to bring the plasma parameter to break even condition. To generate the plasma and bring it to ignition condition in FFHR-d1, it is effective to heat the under/over-dense plasma with normal ECRH or Electron Bernstein Wave (EBW). Normal ECRH is well established but heating via EBW need sophisticated injection control. EBW can be excited via the O(ordinary)-X(extraordinary)-B(EBW) mode conversion process by launching the ordinary wave from the low field side to plasma cut-off layer with optimum injection angle, and the range of injection angle to get high OXB mode conversion rate is called OXB mode conversion window. Since the window position can change as the plasma parameter, it is necessary to optimize the injection angle so as to aim the window in response to the plasma parameters. Candidates of antenna positions are determined by optimum injection points on the plasma facing wall calculated by the injection angle. Given such picked up area, detailed analysis using ray-tracing calculations and engineering antenna design will be performed.
Leança, Camila C; Nunes, Valéria S; Panzoldo, Natália B; Zago, Vanessa S; Parra, Eliane S; Cazita, Patrícia M; Jauhiainen, Matti; Passarelli, Marisa; Nakandakare, Edna R; de Faria, Eliana C; Quintão, Eder C R
2013-11-22
We have searched if plasma high density lipoprotein-cholesterol (HDL-C) concentration interferes simultaneously with whole-body cholesterol metabolism and insulin sensitivity in normal weight healthy adult subjects. We have measured the activities of several plasma components that are critically influenced by insulin and that control lipoprotein metabolism in subjects with low and high HDL-C concentrations. These parameters included cholesteryl ester transfer protein (CETP), phospholipid transfer protein (PLTP), lecithin cholesterol acyl transferase (LCAT), post-heparin lipoprotein lipase (LPL), hepatic lipase (HL), pre-beta-₁HDL, and plasma sterol markers of cholesterol synthesis and intestinal absorption. In the high-HDL-C group, we found lower plasma concentrations of triglycerides, alanine aminotransferase, insulin, HOMA-IR index, activities of LCAT and HL compared with the low HDL-C group; additionally, we found higher activity of LPL and pre-beta-₁HDL concentration in the high-HDL-C group. There were no differences in the plasma CETP and PLTP activities. These findings indicate that in healthy hyperalphalipoproteinemia subjects, several parameters that control the metabolism of plasma cholesterol and lipoproteins are related to a higher degree of insulin sensitivity.
Cold atmospheric plasma treatment inhibits growth in colorectal cancer cells.
Schneider, Christin; Arndt, Stephanie; Zimmermann, Julia L; Li, Yangfang; Karrer, Sigrid; Bosserhoff, Anja-Katrin
2018-06-01
Plasma oncology is a relatively new field of research. Recent developments have indicated that cold atmospheric plasma (CAP) technology is an interesting new therapeutic approach to cancer treatment. In this study, p53 wildtype (LoVo) and human p53 mutated (HT29 and SW480) colorectal cancer cells were treated with the miniFlatPlaSter - a device particularly developed for the treatment of tumor cells - that uses the Surface Micro Discharge (SMD) technology for plasma production in air. The present study analyzed the effects of plasma on colorectal cancer cells in vitro and on normal colon tissue ex vivo. Plasma treatment had strong effects on colon cancer cells, such as inhibition of cell proliferation, induction of cell death, and modulation of p21 expression. In contrast, CAP treatment of murine colon tissue ex vivo for up to 2 min did not show any toxic effect on normal colon cells compared to H2O2 positive control. In summary, these results suggest that the miniFlatPlaSter plasma device is able to kill colorectal cancer cells independent of their p53 mutation status. Thus, this device presents a promising new approach in colon cancer therapy.
Biochemistry of seminal plasma in azoospermic men.
Perez-Pelaez, M; Jeyendran, R S; Alagaratnam, D
1985-01-01
Seminal plasma from 20 azoospermic and 4 vasectomized men and 75 samples from normal ejaculates were quantitated colorimetrically for zinc, fructose, and glycerylphosphorylcholine (GPC) contents. The results were similar to those obtained in the normal ejaculates, in 17 of 21 azoospermic ejaculates, whereas in the vasectomized ejaculates, GPC values were reduced. In the remaining 4 azoospermic ejaculates, less than 15% of fructose and GPC and a zinc content three times higher than normal were detected. Vasogram performed in these 4 azoospermic men revealed occlusion or aplasia of the ampula. The data suggest that biochemical evaluation may aid in differential diagnosis of the etiology of azoospermia.
Impaired sexual maturation associated with sleep apnea syndrome during puberty: a case study.
Mosko, S S; Lewis, E; Sassin, J F
1980-01-01
A 20-year-old hypogonadal man was discovered to have had obstructive sleep apnea syndrome--secondary to hypertrophied tonsils, adenoids, and uvula--spanning the years of puberty. All-night polysomnographic recordings and 24 hr measurements of plasma luteinizing hormone (LH) concentrations (sampling at 20 min intervals) were performed before and after combined tonsillectomy, adenoidectomy, and uvulectomy. Two weeks preoperatively, nocturnal sleep was markedly disturbed by 407 apneic episodes, and the patient was found to be hypogonadotropic. Daytime LH concentrations were in the low-normal range for an adult male, and concentrations fell dramatically during nocturnal sleep. This contrasts with both the sleep-related elevation of LH normally seen in puberty and the adult pattern, where no difference is observed in mean concentrations during waking and sleep. Two week and 6 month postoperative evaluations revealed complete alleviation of the sleep apnea syndrome and normalization of the 24 hr pattern of plasma LH, although LH values remained in the low-normal range. Plasma testosterone concentrations were in the low to low-normal range both pre- and postoperatively. No evidence of continued sexual development, beyond that achieved preoperatively, was observed 20 months after surgery, despite continued relief from apnea. These data suggest that sleep apnea during puberty may impair sexual development by preventing the sleep-related elevation in LH secretion normally observed during a critical period spanning puberty.
Plasma diamine oxidase levels in pregnancy complicated by threatened abortion.
Legge, M; Duff, G B
1981-02-01
Plasma diamine oxidase levels were assayed in 66 patients who presented with pregnancy complicated by threatened abortion. Levels within the normal range were associated with continuing pregnancies, whereas levels below the normal range were associated with subsequent abortion. Among those patients in whom gestation was greater than eight weeks, 66.6% of diamine oxidase levels correctly predicted the pregnancy outcome. Assay of the diamine oxidase levels at eight weeks of gestation or less gave little useful information.
Correlation between plasma homocysteine levels and craving in alcohol dependent stabilized patients.
Coppola, Maurizio; Mondola, Raffaella
2018-06-01
Homocysteine is a sulfur amino acid strictly related with alcohol consumption. In alcoholics, hyperhomocysteinemia can increase the risk of various alcohol-related disorders such as: brain atrophy, epileptic seizures during withdrawal, and mood disorders. To evaluate the correlation among serum homocysteine concentrations, craving, hazardous and harmful patterns of alcohol consumption in patients stabilized for withdrawal symptoms. Participants were adult outpatients accessed at the Addiction Treatment Unit. Alcoholism was assessed using the following tools: Mini-International Neuropsychiatric Interview Plus (MINI Plus), Alcohol Use Disorder Identification test (AUDIT), Visual Analogic Scale for craving (VAS). Furthermore, during the first visit a blood sample was taken from all patients to measure the plasma concentration of both homocysteine and Carboxy Deficient Transferrin (CDT). Differences between groups in socio-demographic and clinical characteristics were analyzed using the t-test and the Mann-Whitney's U test for normally and non-normally distributed data, respectively. Correlation between clinical scale scores and plasma concentration of homocysteine and CDT was evaluated using the Pearson's correlation coefficient and the Kendall's Tau-b bivariate correlation coefficient for normally and non-normally distributed data, respectively. Our study included 92 patients. No difference was found in socio-demographic characteristics between groups. The group with high homocysteine had higher prevalence of mood disorders (p < 0.001), plasma CDT percentage (p < 0.001), VAS score (p < 0.001) and AUDIT score (p < 0.001) than group with normal homocysteine. Plasma homocysteine showed a positive correlation with both VAS score (p < 0.001), and AUDIT score (p < 0.05). In our study, plasma homocysteine concentration is associated with craving, hazardous and harmful patterns of alcohol consumption. In particular, homocysteine is correlated with alcoholism in a bidirectional manner because its level appears to be related with alcohol degree, but simultaneously, hyperhomocysteinemia could enhance the alcohol consumption increasing the severity of craving in a circular self reinforcing mechanism. Copyright © 2017 Elsevier Ltd and European Society for Clinical Nutrition and Metabolism. All rights reserved.
Orozco, Aaron F.; Jorgez, Carolina J.; Ramos-Perez, William D.; Popek, Edwina J.; Yu, Xiaoying; Kozinetz, Claudia A.; Bischoff, Farideh Z.; Lewis, Dorothy E.
2009-01-01
Background The aim of this study was to determine whether DNA-associated micro-particles (MPs) in maternal plasma express fetal-derived human leukocyte antigen-G (HLA-G) or placental alkaline phosphatase (PLAP) and whether the levels differ between women with normotensive pregnancies and preeclampsia. Methods DNA-associated MPs expressing HLA-G or PLAP were examined in the plasma of normal pregnant women and preeclamptic patients using flow cytometric analysis. Results DNA-associated HLA-G+ MPs were significantly increased in maternal plasma compared to plasma from non-pregnant controls (p < 0.005), with highest levels found in first and second trimesters. DNA-associated PLAP+ MPs were also increased in maternal plasma compared to plasma from non-pregnant controls (p < 0.006), with highest levels in second and third trimesters. Term preeclamptic women had higher levels of DNA-associated MPs than control pregnant women. HLA-G+ MPs from the plasma of preeclamptic women had more DNA per MP than HLA-G+ MPs from the plasma of normal pregnant women (p < 0.03). Conclusions HLA-G and PLAP MPs increase in maternal circulation at different times during gestation. DNA amounts per HLA-G+ MP increase in preeclamptic women which might indicate dysfunctional extravillous cytotrophoblasts. PMID:19692120
Non-invasive prenatal detection of achondroplasia using circulating fetal DNA in maternal plasma.
Lim, Ji Hyae; Kim, Mee Jin; Kim, Shin Young; Kim, Hye Ok; Song, Mee Jin; Kim, Min Hyoung; Park, So Yeon; Yang, Jae Hyug; Ryu, Hyun Mee
2011-02-01
To perform a reliable non-invasive detection of the fetal achondroplasia using maternal plasma. We developed a quantitative fluorescent-polymerase chain reaction (QF-PCR) method suitable for detection of the FGFR3 mutation (G1138A) causing achondroplasia. This method was applied in a non-invasive detection of the fetal achondroplasia using circulating fetal-DNA (cf-DNA) in maternal plasma. Maternal plasmas were obtained at 27 weeks of gestational age from women carrying an achondroplasia fetus or a normal fetus. Two percent or less achondroplasia DNA was reliably detected by QF-PCR. In a woman carrying a normal fetus, analysis of cf-DNA showed only one peak of the wild-type G allele. In a woman expected an achondroplasia fetus, analysis of cf-DNA showed the two peaks of wild-type G allele and mutant-type A allele and accurately detected the fetal achondroplasia. The non-invasive method using maternal plasma and QF-PCR may be useful for diagnosis of the fetal achondroplasia.
Non-inductively driven tokamak plasmas at near-unity βt in the Pegasus toroidal experiment
NASA Astrophysics Data System (ADS)
Reusch, J. A.; Bodner, G. M.; Bongard, M. W.; Burke, M. G.; Fonck, R. J.; Pachicano, J. L.; Perry, J. M.; Pierren, C.; Rhodes, A. T.; Richner, N. J.; Rodriguez Sanchez, C.; Schlossberg, D. J.; Weberski, J. D.
2018-05-01
A major goal of the spherical tokamak (ST) research program is accessing a state of low internal inductance ℓi, high elongation κ, and high toroidal and normalized beta ( βt and βN) without solenoidal current drive. Local helicity injection (LHI) in the Pegasus ST [Garstka et al., Nucl. Fusion 46, S603 (2006)] provides non-solenoidally driven plasmas that exhibit these characteristics. LHI utilizes compact, edge-localized current sources for plasma startup and sustainment. It results in hollow current density profiles with low ℓi. The low aspect ratio ( R0/a ˜1.2 ) of Pegasus allows access to high κ and high normalized plasma currents ( IN=Ip/a BT>14 ). Magnetic reconnection during LHI provides auxiliary ion heating. Together, these features provide access to very high βt plasmas. Equilibrium analyses indicate that βt up to ˜100% is achieved. These high βt discharges disrupt at the ideal no-wall β limit at βN˜7.
PROTEIN METABOLISM AND EXCHANGE AS INFLUENCED BY CONSTRICTION OF THE VENA CAVA
McKee, Frank W.; Hyatt, Robert E.; Wilt, William G.; Tishkoff, Garson H.; Whipple, George H.
1949-01-01
Further studies of ascitic fluid production and related factors in dogs with constriction of the vena cava above the diaphragm are reported. Whole dog plasma given intravenously to such animals produces a rise in circulating plasma protein to normal levels, but increases the output of ascitic fluid with a loss of protein via the ascites equivalent to 72, 76, and 65 per cent respectively, of the injected protein. Forced ingestion of water in excess of the test animal's normal needs and desires produces no significant changes in the circulating plasma protein level or in ascitic fluid production. Amino acid growth mixtures given intravenously in distilled water cause weight loss, elevation of circulating plasma proteins, a slightly negative nitrogen balance, but no ascitic fluid production. Amino acid growth mixtures given intravenously in normal saline cause depression of the circulating plasma proteins, negative nitrogen balance, and significant ascitic fluid production. Ascitic fluid given intravenously to the test animals causes a marked depression of circulating plasma proteins, a marked increase in ascitic fluid production containing the equivalent of 116 and 98 per cent of the injected protein, and a negative nitrogen balance. Ascitic fluid given orally produces a marked depression of circulating plasma proteins, and a marked increase in ascitic fluid secretion, containing the equivalent of 66, 66, and 54 per cent respectively, of the ingested protein. Sodium chloride is a dominant factor in some of these experiments where abundant ascites production is recorded. Protein levels and intake are important, but take second place to sodium. Ascitic fluids show electrophoretic patterns which are almost identical to the plasma patterns. The A/G ratios are often equal in ascitic fluid and plasma, sometimes even lower in the ascitic fluid. This emphasizes the ease with which globulins pass cell or other membrane barriers in these experiments. PMID:18143588
Schmitzer, C; Kronberger, M; Lettry, J; Sanchez-Arias, J; Störi, H
2012-02-01
The CERN study for a superconducting proton Linac (SPL) investigates the design of a pulsed 5 GeV Linac operating at 50 Hz. As a first step towards a future SPL H(-) volume ion source, a plasma generator capable of operating at Linac4 or nominal SPL settings has been developed and operated at a dedicated test stand. The hydrogen plasma is heated by an inductively coupled RF discharge e(-) and ions are confined by a magnetic multipole cusp field similar to the currently commissioned Linac4 H(-) ion source. Time-resolved measurements of the plasma potential, temperature, and electron energy distribution function obtained by means of a RF compensated Langmuir probe along the axis of the plasma generator are presented. The influence of the main tuning parameters, such as RF power and frequency and the timing scheme is discussed with the aim to correlate them to optimum H(-) ion beam parameters measured on an ion source test stand. The effects of hydrogen injection settings which allow operation at 50 Hz repetition rate are discussed.
NASA Astrophysics Data System (ADS)
Schmitzer, C.; Kronberger, M.; Lettry, J.; Sanchez-Arias, J.; Störi, H.
2012-02-01
The CERN study for a superconducting proton Linac (SPL) investigates the design of a pulsed 5 GeV Linac operating at 50 Hz. As a first step towards a future SPL H- volume ion source, a plasma generator capable of operating at Linac4 or nominal SPL settings has been developed and operated at a dedicated test stand. The hydrogen plasma is heated by an inductively coupled RF discharge e- and ions are confined by a magnetic multipole cusp field similar to the currently commissioned Linac4 H- ion source. Time-resolved measurements of the plasma potential, temperature, and electron energy distribution function obtained by means of a RF compensated Langmuir probe along the axis of the plasma generator are presented. The influence of the main tuning parameters, such as RF power and frequency and the timing scheme is discussed with the aim to correlate them to optimum H- ion beam parameters measured on an ion source test stand. The effects of hydrogen injection settings which allow operation at 50 Hz repetition rate are discussed.
High frequency plasma generator for ion thrusters
NASA Technical Reports Server (NTRS)
Goede, H.; Divergilio, W. F.; Fosnight, V. V.; Komatsu, G.
1984-01-01
The results of a program to experimentally develop two new types of plasma generators for 30 cm electrostatic argon ion thrusters are presented. The two plasma generating methods selected for this study were by radio frequency induction (RFI), operating at an input power frequency of 1 MHz, and by electron cyclotron heating (ECH) at an operating frequency of 5.0 GHz. Both of these generators utilize multiline cusp permanent magnet configurations for plasma confinement and beam profile optimization. The program goals were to develop a plasma generator possessing the characteristics of high electrical efficiency (low eV/ion) and simplicity of operation while maintaining the reliability and durability of the conventional hollow cathode plasma sources. The RFI plasma generator has achieved minimum discharge losses of 120 eV/ion while the ECH generator has obtained 145 eV/ion, assuming a 90% ion optical transparency of the electrostatic acceleration system. Details of experimental tests with a variety of magnet configurations are presented.
Andoh, Yoshimichi; Okazaki, Susumu; Ueoka, Ryuichi
2013-04-01
Molecular dynamics (MD) calculations for the plasma membranes of normal murine thymocytes and thymus-derived leukemic GRSL cells in water have been performed under physiological isothermal-isobaric conditions (310.15K and 1 atm) to investigate changes in membrane properties induced by canceration. The model membranes used in our calculations for normal and leukemic thymocytes comprised 23 and 25 kinds of lipids, respectively, including phosphatidylcholine, phosphatidylethanolamine, phosphatidylserine, phosphatidylinositol, sphingomyelin, lysophospholipids, and cholesterol. The mole fractions of the lipids adopted here were based on previously published experimental values. Our calculations clearly showed that the membrane area was increased in leukemic cells, and that the isothermal area compressibility of the leukemic plasma membranes was double that of normal cells. The calculated membranes of leukemic cells were thus considerably bulkier and softer in the lateral direction compared with those of normal cells. The tilt angle of the cholesterol and the conformation of the phospholipid fatty acid tails both showed a lower level of order in leukemic cell membranes compared with normal cell membranes. The lateral radial distribution function of the lipids also showed a more disordered structure in leukemic cell membranes than in normal cell membranes. These observations all show that, for the present thymocytes, the lateral structure of the membrane is considerably disordered by canceration. Furthermore, the calculated lateral self-diffusion coefficient of the lipid molecules in leukemic cell membranes was almost double that in normal cell membranes. The calculated rotational and wobbling autocorrelation functions also indicated that the molecular motion of the lipids was enhanced in leukemic cell membranes. Thus, here we have demonstrated that the membranes of thymocyte leukemic cells are more disordered and more fluid than normal cell membranes. Copyright © 2013 Elsevier B.V. All rights reserved.
Technical challenges in the construction of the steady-state stellarator Wendelstein 7-X
NASA Astrophysics Data System (ADS)
Bosch, H.-S.; Wolf, R. C.; Andreeva, T.; Baldzuhn, J.; Birus, D.; Bluhm, T.; Bräuer, T.; Braune, H.; Bykov, V.; Cardella, A.; Durodié, F.; Endler, M.; Erckmann, V.; Gantenbein, G.; Hartmann, D.; Hathiramani, D.; Heimann, P.; Heinemann, B.; Hennig, C.; Hirsch, M.; Holtum, D.; Jagielski, J.; Jelonnek, J.; Kasparek, W.; Klinger, T.; König, R.; Kornejew, P.; Kroiss, H.; Krom, J. G.; Kühner, G.; Laqua, H.; Laqua, H. P.; Lechte, C.; Lewerentz, M.; Maier, J.; McNeely, P.; Messiaen, A.; Michel, G.; Ongena, J.; Peacock, A.; Pedersen, T. S.; Riedl, R.; Riemann, H.; Rong, P.; Rust, N.; Schacht, J.; Schauer, F.; Schroeder, R.; Schweer, B.; Spring, A.; Stäbler, A.; Thumm, M.; Turkin, Y.; Wegener, L.; Werner, A.; Zhang, D.; Zilker, M.; Akijama, T.; Alzbutas, R.; Ascasibar, E.; Balden, M.; Banduch, M.; Baylard, Ch.; Behr, W.; Beidler, C.; Benndorf, A.; Bergmann, T.; Biedermann, C.; Bieg, B.; Biel, W.; Borchardt, M.; Borowitz, G.; Borsuk, V.; Bozhenkov, S.; Brakel, R.; Brand, H.; Brown, T.; Brucker, B.; Burhenn, R.; Buscher, K.-P.; Caldwell-Nichols, C.; Cappa, A.; Cardella, A.; Carls, A.; Carvalho, P.; Ciupiński, Ł.; Cole, M.; Collienne, J.; Czarnecka, A.; Czymek, G.; Dammertz, G.; Dhard, C. P.; Davydenko, V. I.; Dinklage, A.; Drevlak, M.; Drotziger, S.; Dudek, A.; Dumortier, P.; Dundulis, G.; Eeten, P. v.; Egorov, K.; Estrada, T.; Faugel, H.; Fellinger, J.; Feng, Y.; Fernandes, H.; Fietz, W. H.; Figacz, W.; Fischer, F.; Fontdecaba, J.; Freund, A.; Funaba, T.; Fünfgelder, H.; Galkowski, A.; Gates, D.; Giannone, L.; García Regaña, J. M.; Geiger, J.; Geißler, S.; Greuner, H.; Grahl, M.; Groß, S.; Grosman, A.; Grote, H.; Grulke, O.; Haas, M.; Haiduk, L.; Hartfuß, H.-J.; Harris, J. H.; Haus, D.; Hein, B.; Heitzenroeder, P.; Helander, P.; Heller, R.; Hidalgo, C.; Hildebrandt, D.; Höhnle, H.; Holtz, A.; Holzhauer, E.; Holzthüm, R.; Huber, A.; Hunger, H.; Hurd, F.; Ihrke, M.; Illy, S.; Ivanov, A.; Jablonski, S.; Jaksic, N.; Jakubowski, M.; Jaspers, R.; Jensen, H.; Jenzsch, H.; Kacmarczyk, J.; Kaliatk, T.; Kallmeyer, J.; Kamionka, U.; Karaleviciu, R.; Kern, S.; Keunecke, M.; Kleiber, R.; Knauer, J.; Koch, R.; Kocsis, G.; Könies, A.; Köppen, M.; Koslowski, R.; Koshurinov, J.; Krämer-Flecken, A.; Krampitz, R.; Kravtsov, Y.; Krychowiak, M.; Krzesinski, G.; Ksiazek, I.; Kubkowska, M.; Kus, A.; Langish, S.; Laube, R.; Laux, M.; Lazerson, S.; Lennartz, M.; Li, C.; Lietzow, R.; Lohs, A.; Lorenz, A.; Louche, F.; Lubyako, L.; Lumsdaine, A.; Lyssoivan, A.; Maaßberg, H.; Marek, P.; Martens, C.; Marushchenko, N.; Mayer, M.; Mendelevitch, B.; Mertens, Ph.; Mikkelsen, D.; Mishchenko, A.; Missal, B.; Mizuuchi, T.; Modrow, H.; Mönnich, T.; Morizaki, T.; Murakami, S.; Musielok, F.; Nagel, M.; Naujoks, D.; Neilson, H.; Neubauer, O.; Neuner, U.; Nocentini, R.; Noterdaeme, J.-M.; Nührenberg, C.; Obermayer, S.; Offermanns, G.; Oosterbeek, H.; Otte, M.; Panin, A.; Pap, M.; Paquay, S.; Pasch, E.; Peng, X.; Petrov, S.; Pilopp, D.; Pirsch, H.; Plaum, B.; Pompon, F.; Povilaitis, M.; Preinhaelter, J.; Prinz, O.; Purps, F.; Rajna, T.; Récsei, S.; Reiman, A.; Reiter, D.; Remmel, J.; Renard, S.; Rhode, V.; Riemann, J.; Rimkevicius, S.; Riße, K.; Rodatos, A.; Rodin, I.; Romé, M.; Roscher, H.-J.; Rummel, K.; Rummel, Th.; Runov, A.; Ryc, L.; Sachtleben, J.; Samartsev, A.; Sanchez, M.; Sano, F.; Scarabosio, A.; Schmid, M.; Schmitz, H.; Schmitz, O.; Schneider, M.; Schneider, W.; Scheibl, L.; Scholz, M.; Schröder, G.; Schröder, M.; Schruff, J.; Schumacher, H.; Shikhovtsev, I. V.; Shoji, M.; Siegl, G.; Skodzik, J.; Smirnow, M.; Speth, E.; Spong, D. A.; Stadler, R.; Sulek, Z.; Szabó, V.; Szabolics, T.; Szetefi, T.; Szökefalvi-Nagy, Z.; Tereshchenko, A.; Thomsen, H.; Thumm, M.; Timmermann, D.; Tittes, H.; Toi, K.; Tournianski, M.; Toussaint, U. v.; Tretter, J.; Tulipán, S.; Turba, P.; Uhlemann, R.; Urban, J.; Urbonavicius, E.; Urlings, P.; Valet, S.; Van Eester, D.; Van Schoor, M.; Vervier, M.; Viebke, H.; Vilbrandt, R.; Vrancken, M.; Wauters, T.; Weissgerber, M.; Weiß, E.; Weller, A.; Wendorf, J.; Wenzel, U.; Windisch, T.; Winkler, E.; Winkler, M.; Wolowski, J.; Wolters, J.; Wrochna, G.; Xanthopoulos, P.; Yamada, H.; Yokoyama, M.; Zacharias, D.; Zajac, J.; Zangl, G.; Zarnstorff, M.; Zeplien, H.; Zoletnik, S.; Zuin, M.
2013-12-01
The next step in the Wendelstein stellarator line is the large superconducting device Wendelstein 7-X, currently under construction in Greifswald, Germany. Steady-state operation is an intrinsic feature of stellarators, and one key element of the Wendelstein 7-X mission is to demonstrate steady-state operation under plasma conditions relevant for a fusion power plant. Steady-state operation of a fusion device, on the one hand, requires the implementation of special technologies, giving rise to technical challenges during the design, fabrication and assembly of such a device. On the other hand, also the physics development of steady-state operation at high plasma performance poses a challenge and careful preparation. The electron cyclotron resonance heating system, diagnostics, experiment control and data acquisition are prepared for plasma operation lasting 30 min. This requires many new technological approaches for plasma heating and diagnostics as well as new concepts for experiment control and data acquisition.
Historical overview of HF ionospheric modification research
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gordon, W.E.; Duncan, L.M.
1990-10-01
Radio waves have inadvertently modified the Earth's ionosphere since the Luxembourg observations of Tellegen in 1933 and perhaps since Marconi in 1901. The history of ionospheric modification by radio waves is reviewed, beginning with Marconi, describing the Luxembourg effect and its explanations, and its early use to deduce the properties of the lower ionosphere in the 1930s. The measurements became more sophisticated in the 1950s, leading to the call for high-power high-frequency modification experiments in the upper ionosphere. Beginning in 1970, radio facilities became available of sufficient powers to induce changes in the ionospheric plasma detectable by a wide arraymore » of diagnostic instruments and techniques. A summary of these effects is presented based upon work up to 1990. These studies were originally motivated as a means of better understanding the natural ionosphere using a weak perturbational approach. However, a rich spectrum of nonlinear wave-plasma interactions was quickly discovered and ionospheric modification research became strongly motivated by issues in basic plasma physics. The ionosphere and near-Earth space are now exploited as an exceptional plasma laboratory-without-walls for the study of fundamental plasma processes requiring large spatial or temporal scales. Here we present a brief overview of these processes and phenomena, illustrated using results obtained from the Arecibo ionospheric modification facilities. The lessons learned and phenomena explored thus far offer many opportunities for controlling the ionospheric environment critical to many civilian and military telecommunications systems, both to disrupt systems normally operational and to create new propagation paths otherwise unavailable.« less
Emission characteristics of 6.78-MHz radio-frequency glow discharge plasma in a pulsed mode
NASA Astrophysics Data System (ADS)
Zhang, Xinyue; Wagatsuma, Kazuaki
2017-07-01
This paper investigated Boltzmann plots for both atomic and ionic emission lines of iron in an argon glow discharge plasma driven by 6.78-MHz radio-frequency (RF) voltage in a pulsed operation, in order to discuss how the excitation/ionization process was affected by the pulsation. For this purpose, a pulse frequency as well as a duty ratio of the pulsed RF voltage was selected as the experimenter parameters. A Grimm-style radiation source was employed at a forward RF power of 70 W and at an argon pressures of 670 Pa. The Boltzmann plot for low-lying excited levels of iron atom was on a linear relationship, which was probably attributed to thermal collisions with ultimate electrons in the negative glow region; in this case, the excitation temperature was obtained in a narrow range of 3300-3400 K, which was hardly affected by the duty ratio as well as the pulse frequency of the pulsed RF glow discharge plasma. This observation suggested that the RF plasma could be supported by a self-stabilized negative glow region, where the kinetic energy distribution of the electrons would be changed to a lesser extent. Additional non-thermal excitation processes, such as a Penning-type collision and a charge-transfer collision, led to deviations (overpopulation) of particular energy levels of iron atom or iron ion from the normal Boltzmann distribution. However, their contributions to the overall excitation/ionization were not altered so greatly, when the pulse frequency or the duty ratio was varied in the pulsed RF glow discharge plasma.
NASA Astrophysics Data System (ADS)
Goldston, Robert; Brooks, Jeffrey; Hubbard, Amanda; Leonard, Anthony; Lipschultz, Bruce; Maingi, Rajesh; Ulrickson, Michael; Whyte, Dennis
2009-11-01
The plasma facing components in a Demo reactor will face much more extreme boundary plasma conditions and operating requirements than any present or planned experiment. These include 1) Power density a factor of four or more greater than in ITER, 2) Continuous operation resulting in annual energy and particle throughput 100-200 times larger than ITER, 3) Elevated surface operating temperature for efficient electricity production, 4) Tritium fuel cycle control for safety and breeding requirements, and 5) Steady state plasma confinement and control. Consistent with ReNeW Thrust 12, design options are being explored for a new moderate-scale facility to assess core-edge interaction issues and solutions. Key desired features include high power density, sufficient pulse length and duty cycle, elevated wall temperature, steady-state control of an optimized core plasma, and flexibility in changing boundary components as well as access for comprehensive measurements.
NASA Technical Reports Server (NTRS)
Kurth, W. S.
1984-01-01
The Plasma Diagnostics Package, which was flown aboard STS-3 recorded various chemical releases from the Orbiter. Changes in the plasma environment were observed to occur during Flash Evaporator System (FES) releases, water dumps and maneuvering thruster operations. During flash evaporator operations, broadband Orbiter-generated electro-static noise is enhanced and plasma density irregularity (delta n/N) is observed to increase by as much as 4 times and is strongly peaked below 6 Hz. In the case of water dumps, background electrostatic noise is enhanced or suppressed depending on frequency and Delta N/N is also seen to increase by as much as 4 times. Various changes in the plasma environment are effected by primary and vernier thruster operations. In addition, thruster activity stimulates electrostatic noise with a spectrum which is most intense at frequencies below 10 kHz.
ECR plasma thruster research - Preliminary theory and experiments
NASA Technical Reports Server (NTRS)
Sercel, Joel C.; Fitzgerald, Dennis J.
1989-01-01
A preliminary theory of the operation of the electron-cyclotron-resonance (ECR) plasma thruster is described along with an outline of recent experiments. This work is presented to communicate the status of an ongoing research effort directed at developing a unified theory to quantitatively describe the operation of the ECR plasma thruster. The theory is presented as a set of nonlinear ordinary differential equations and boundary conditions which describe the plasma density, velocity, and electron temperature. Diagnostic tools developed to measure plasma conditions in the existing research device are described.
OBSERVATIONS CONCERNING THE PRODUCTION AND EXCRETION OF CHOLESTEROL IN MAMMALS
Byers, Sanford O.; Friedman, Meyer; Biggs, Max W.; Gunning, Barbara
1953-01-01
Accumulation of cholate in plasma is the immediate cause of hypercholesteremia in the rat with bile duct ligation and in the normal rat given intravenous sodium cholate. The hypercholesteremia induced by cholate administration does not appear to be dependent upon any preceding change in the rates of absorption, excretion, synthesis, or redistribution of cholesterol in the tissues of the animal. Cholate administration seems to induce hypercholesteremia by impeding the normal rate of passage of cholesterol from the plasma into the liver; this impedance is probably due to an alteration of the cholesterol-binding power of plasma proteins induced by cholate. The chemical and physiological implications of this finding are discussed. PMID:13052817
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kurapov, Denis; Reiss, Jennifer; Trinh, David H.
2007-07-15
Alumina thin films were deposited onto tempered hot working steel substrates from an AlCl{sub 3}-O{sub 2}-Ar-H{sub 2} gas mixture by plasma-assisted chemical vapor deposition. The normalized ion flux was varied during deposition through changes in precursor content while keeping the cathode voltage and the total pressure constant. As the precursor content in the total gas mixture was increased from 0.8% to 5.8%, the deposition rate increased 12-fold, while the normalized ion flux decreased by approximately 90%. The constitution, morphology, impurity incorporation, and the elastic properties of the alumina thin films were found to depend on the normalized ion flux. Thesemore » changes in structure, composition, and properties induced by normalized ion flux may be understood by considering mechanisms related to surface and bulk diffusion.« less
Bartosh, Nicole S; Tomlin, Tara; Cable, Christian; Halka, Kathleen
2013-01-01
This case report presents a newly diagnosed congenital factor VII deficiency treated with recombinant activated factor VII (rFVIIa). Congenital factor VII deficiency is a rare autosomal-recessive bleeding disorder that occurs in fewer than 1/500,000 persons. Its presentation can vary from epistaxis to hemarthroses and severe central nervous system bleeding, and correlates poorly with factor VII levels. Our patient had not had a significant hemostatic challenge prior to his presentation and therefore never had any symptomatology suggestive of this disease. He was treated with rFVIIa, and was able to undergo repair of his fractures without bleeding. Case report A 19-year-old African-American male presented to the emergency room after an altercation that resulted in significant trauma. He sustained bilateral mandibular angle fractures and orbital floor fractures, requiring urgent surgical correction. On initial evaluation, he was noted to have a prolonged prothrombin time of 40.1 seconds, with an International Normalized Ratio of 4.0, a normal activated partial thromboplastin time of 29.9 seconds, and a platelet count of 241. After receiving vitamin K and fresh frozen plasma, he was taken to the operating room for a temporary rigid maxillomandibular fixation. A 1:1 mixing study with normal plasma corrected the prothrombin time (decreasing from 40.7 to 14.7 seconds) and a factor VII assay revealed 5% of the normal factor VII level. The patient was diagnosed with congenital factor VII deficiency. Due to his coagulopathy and the extensive surgical correction needed, rFVIIa was administered and surgery was accomplished without hemorrhagic sequelae. Conclusion This case report and review describes a rare congenital disease, the history of rFVIIa use, and its mechanism. rFVIIA use in our patient provided a treatment option that allowed the necessary surgical correction, but further prospective studies on dose optimization would ensure adequate dosing with minimal risk of severe side effects. PMID:23516010
Bartosh, Nicole S; Tomlin, Tara; Cable, Christian; Halka, Kathleen
2013-01-01
This case report presents a newly diagnosed congenital factor VII deficiency treated with recombinant activated factor VII (rFVIIa). Congenital factor VII deficiency is a rare autosomal-recessive bleeding disorder that occurs in fewer than 1/500,000 persons. Its presentation can vary from epistaxis to hemarthroses and severe central nervous system bleeding, and correlates poorly with factor VII levels. Our patient had not had a significant hemostatic challenge prior to his presentation and therefore never had any symptomatology suggestive of this disease. He was treated with rFVIIa, and was able to undergo repair of his fractures without bleeding. A 19-year-old African-American male presented to the emergency room after an altercation that resulted in significant trauma. He sustained bilateral mandibular angle fractures and orbital floor fractures, requiring urgent surgical correction. On initial evaluation, he was noted to have a prolonged prothrombin time of 40.1 seconds, with an International Normalized Ratio of 4.0, a normal activated partial thromboplastin time of 29.9 seconds, and a platelet count of 241. After receiving vitamin K and fresh frozen plasma, he was taken to the operating room for a temporary rigid maxillomandibular fixation. A 1:1 mixing study with normal plasma corrected the prothrombin time (decreasing from 40.7 to 14.7 seconds) and a factor VII assay revealed 5% of the normal factor VII level. The patient was diagnosed with congenital factor VII deficiency. Due to his coagulopathy and the extensive surgical correction needed, rFVIIa was administered and surgery was accomplished without hemorrhagic sequelae. This case report and review describes a rare congenital disease, the history of rFVIIa use, and its mechanism. rFVIIA use in our patient provided a treatment option that allowed the necessary surgical correction, but further prospective studies on dose optimization would ensure adequate dosing with minimal risk of severe side effects.
NASA Astrophysics Data System (ADS)
Stork, D.; Baranov, Yu.; Belo, P.; Bertalot, L.; Borba, D.; Brzozowski, J. H.; Challis, C. D.; Ciric, D.; Conroy, S.; de Baar, M.; de Vries, P.; Dumortier, P.; Garzotti, L.; Hawkes, N. C.; Hender, T. C.; Joffrin, E.; Jones, T. T. C.; Kiptily, V.; Lamalle, P.; Mailloux, J.; Mantsinen, M.; McDonald, D. C.; Nave, M. F. F.; Neu, R.; O'Mullane, M.; Ongena, J.; Pearce, R. J.; Popovichev, S.; Sharapov, S. E.; Stamp, M.; Stober, J.; Surrey, E.; Valovic, M.; Voitsekhovitch, I.; Weisen, H.; Whiteford, A. D.; Worth, L.; Yavorskij, V.; Zastrow, K.-D.; EFDA contributors, JET
2005-10-01
Results are presented from the JET Trace Tritium Experimental (TTE) campaign using minority tritium (T) plasmas (nT/nD < 3%). Thermal tritium particle transport coefficients (DT, vT) are found to exceed neo-classical values in all regimes, except in ELMy H-modes at high densities and in the region of internal transport barriers (ITBs) in reversed shear plasmas. In ELMy H-mode dimensionless parameter scans, at q95 ~ 2.8 and triangularity δ = 0.2, the T particle transport scales in a gyro-Bohm manner in the inner plasma (r/a < 0.4), whilst the outer plasma particle transport scaling is more Bohm-like. Dimensionless parameter scans show contrasting behaviour for the trace particle confinement (increases with collisionality, ν* and β) and bulk energy confinement (decreases with ν* and is independent of β). In an extended ELMy H-mode data set, with ρ*, ν*, β and q varied but with neo-classical tearing modes (NTMs) either absent or limited to weak, benign core modes (4/3 or above), the multiparameter fit to the normalized diffusion coefficient in the outer plasma (0.65 < r/a < 0.8) gives DT/Bphi ~ ρ*2.46ν*-0.23β-1.01q2.03. In hybrid scenarios (qmin ~ 1, low positive shear, no sawteeth), the T particle confinement is found to scale with increasing triangularity and plasma current. Comparing regimes (ELMy H-mode, ITB plasma and hybrid scenarios) in the outer plasma region, a correlation of high values of DT with high values of vT is seen. The normalized diffusion coefficients for the hybrid and ITB scenarios do not fit the scaling derived for ELMy H-modes. The normalized tritium diffusion scales with normalized poloidal Larmor radius (\\rho_{\\theta}^\\ast=q\\rho^{\\ast}) in a manner close to gyro-Bohm ({\\sim}\\rho_{\\theta}^{\\ast 3}) , with an added inverse β dependence. The effects of ELMs, sawteeth and NTMs on the T particle transport are described. Fast-ion confinement in current-hole (CH) plasmas was tested in TTE by tritium neutral beam injection into JET CH plasmas. γ-rays from the reactions of fusion alpha and beryllium impurities (9Be(α, nγ)12C) characterized the fast fusion-alpha population evolution. The γ-decay times are consistent with classical alpha plus parent fast triton slowing down times (τTs + ταs) for high plasma currents (Ip > 2 MA) and monotonic q-profiles. In CH discharges the γ-ray emission decay times are much lower than classical (τTs+ταs), indicating alpha confinement degradation, due to the orbit losses and particle orbit drift predicted by a 3-D Fokker-Planck numerical code and modelled using TRANSP.
On the quantum Landau collision operator and electron collisions in dense plasmas
DOE Office of Scientific and Technical Information (OSTI.GOV)
Daligault, Jérôme, E-mail: daligaul@lanl.gov
2016-03-15
The quantum Landau collision operator, which extends the widely used Landau/Fokker-Planck collision operator to include quantum statistical effects, is discussed. The quantum extension can serve as a reference model for including electron collisions in non-equilibrium dense plasmas, in which the quantum nature of electrons cannot be neglected. In this paper, the properties of the Landau collision operator that have been useful in traditional plasma kinetic theory and plasma transport theory are extended to the quantum case. We outline basic properties in connection with the conservation laws, the H-theorem, and the global and local equilibrium distributions. We discuss the Fokker-Planck formmore » of the operator in terms of three potentials that extend the usual two Rosenbluth potentials. We establish practical closed-form expressions for these potentials under local thermal equilibrium conditions in terms of Fermi-Dirac and Bose-Einstein integrals. We study the properties of linearized quantum Landau operator, and extend two popular approximations used in plasma physics to include collisions in kinetic simulations. We apply the quantum Landau operator to the classic test-particle problem to illustrate the physical effects embodied in the quantum extension. We present useful closed-form expressions for the electron-ion momentum and energy transfer rates. Throughout the paper, similarities and differences between the quantum and classical Landau collision operators are emphasized.« less
On the quantum Landau collision operator and electron collisions in dense plasmas
NASA Astrophysics Data System (ADS)
Daligault, Jérôme
2016-03-01
The quantum Landau collision operator, which extends the widely used Landau/Fokker-Planck collision operator to include quantum statistical effects, is discussed. The quantum extension can serve as a reference model for including electron collisions in non-equilibrium dense plasmas, in which the quantum nature of electrons cannot be neglected. In this paper, the properties of the Landau collision operator that have been useful in traditional plasma kinetic theory and plasma transport theory are extended to the quantum case. We outline basic properties in connection with the conservation laws, the H-theorem, and the global and local equilibrium distributions. We discuss the Fokker-Planck form of the operator in terms of three potentials that extend the usual two Rosenbluth potentials. We establish practical closed-form expressions for these potentials under local thermal equilibrium conditions in terms of Fermi-Dirac and Bose-Einstein integrals. We study the properties of linearized quantum Landau operator, and extend two popular approximations used in plasma physics to include collisions in kinetic simulations. We apply the quantum Landau operator to the classic test-particle problem to illustrate the physical effects embodied in the quantum extension. We present useful closed-form expressions for the electron-ion momentum and energy transfer rates. Throughout the paper, similarities and differences between the quantum and classical Landau collision operators are emphasized.
The correlation between plasma osmolarity and tear osmolarity.
Kobayashi, Maika; Igarashi, Tsutomu; Takahashi, Hisatomo; Fujimoto, Chiaki; Suzuki, Hisaharu; Takahashi, Hiroshi
2018-04-01
To the correlation between plasma osmolarity (Posm) and tear osmolarity (Tosm) in patients (54 patients, 88 eyes) who underwent cataract surgery was evaluated. Before cataract surgery, routine pre-operative biochemical tests were performed, and Posm was determined from blood samples. Also, Tosm was measured using the TearLab system, and objective signs including tear break-up time (BUT), fluorescein staining, lissamine green staining, and Schirmer's test were evaluated. Dry eye (DE) was diagnosed according to the Japanese criteria for DE. Of the 88 eyes, 4 were diagnosed as definite DE, 70 as probable DE, and 14 as normal. Since the number of definite DE was small, the eyes were divided into two groups: normal group (n = 14) and DE group (n = 74), which included definite DE (n = 4) and probable DE (n = 70). There was no correlation between Posm and Tosm, though Posm (293.32 mOsm/L) was significantly higher than Tosm (288.48 mOsm/L; p < 0.001). There was no significant difference in Tosm between the normal group (288.29 mOsm/L) and the DE group (288.51 mOsm/L). No patients had a Tosm higher than 310 mOsm/L even in the DE group. Correlations between Posm/Tosm and each DE sign value were not found. Of 54 patients, 18 were diabetic. Posm was significantly higher in diabetic (295.78 mOsm/L) than in non-diabetic (292.36 mOsm/L; p = 0.014) patients, while there was no significant difference in Tosm between diabetic and non-diabetic patients. The results suggest that Tosm is independent of Posm, and Tosm elevation in DE occurs by some local mechanisms.
Pineda, A A; Valbonesi, M
1990-04-01
Interest in and use of IBS have increased recently. This form of haemotherapy involves the retrieval of blood shed perioperatively. IBS, together with other forms of ABT, has gained a prominent role in transfusion medicine, largely due to an increased awareness of the risks associated with transfusion of homologous blood. In addition to conserving erythrocytes, IBS prevents disease transmission, other adverse transfusion reactions, and alloimmunization to antigens in blood cells and plasma which may result from homologous blood use. An array of IBS devices is presently available, ranging from disposable canisters to complete processing systems. The devices are capable of recovering, filtering, washing and reinfusing shed erythrocytes. They can be divided into slow-flow and rapid-flow systems based on the rapidity of blood processing. Most systems use a dual channel aspiration cannula through which shed blood is aspirated and mixed with anticoagulant solution. The salvage procedure requires operator control at every step, even for the highly automated instruments. Various health care personnel have been trained to operate IBS equipment; a transfusion service nurse with blood bank expertise has proved to be a highly reliable operator in our practice. Extensive clinical observation has shown that salvaged erythrocytes function and survive normally. IBS has been applied in many surgical fields; it has two relative contraindications: its use in areas affected by infection or malignancy. Operative procedures characterized by large blood losses provide a cost-efficient application of IBS, including cardiac surgery, orthopaedic procedures, trauma, vascular surgery, and liver transplantation. New, highly efficient technology is emerging that is capable of recovering other blood components. Consequently, what presently amounts to erythrocyte recovery will be expanded shortly to include platelets and plasma, with its many constituents.
Localization and molecular forms of galanin in human adrenals: elevated levels in pheochromocytomas.
Bauer, F E; Hacker, G W; Terenghi, G; Adrian, T E; Polak, J M; Bloom, S R
1986-12-01
Galanin immunoreactivity was measured by RIA, using antibodies directed against both the non-C- and C-terminal positions of porcine galanin, in tissue extracts of normal adrenals and pheochromocytomas and also in the plasma of normal subjects and patients with pheochromocytomas. No C-terminal galanin-like immunoreactivity was detected in plasma or tissue, suggesting differences in the amino acid sequence of human compared with porcine galanin. A non-C-terminally directed antibody was, therefore, used to characterize human galanin immunoreactivity by gel permeation chromatography and reverse phase high pressure liquid chromatography and to localize it by immunocytochemistry. The galanin content of whole adrenal gland was 2.6 +/- 0.9 (+/- SEM) pmol/g (n = 5). In contrast, however, pheochromocytomas had much greater concentrations (21 +/- 2.3 pmol/g; n = 16). Gel chromatography and reverse phase high pressure liquid chromatography revealed 2 molecular forms of galanin immunoreactivity with identical elution positions in both normal adrenals and tumors. The concentration of galanin in plasma from both normal subjects and pheochromocytoma patients was below the detection limit of the assay (less than 10 pmol/liter). Using immunocytochemistry, galanin was localized to scattered cells or clusters of tumor cells in 5 of 11 pheochromocytomas and only a few chromaffin cells and cortical nerve fibers in normal adrenals.
The spectral theorem for quaternionic unbounded normal operators based on the S-spectrum
DOE Office of Scientific and Technical Information (OSTI.GOV)
Alpay, Daniel, E-mail: dany@math.bgu.ac.il; Kimsey, David P., E-mail: dpkimsey@gmail.com; Colombo, Fabrizio, E-mail: fabrizio.colombo@polimi.it
In this paper we prove the spectral theorem for quaternionic unbounded normal operators using the notion of S-spectrum. The proof technique consists of first establishing a spectral theorem for quaternionic bounded normal operators and then using a transformation which maps a quaternionic unbounded normal operator to a quaternionic bounded normal operator. With this paper we complete the foundation of spectral analysis of quaternionic operators. The S-spectrum has been introduced to define the quaternionic functional calculus but it turns out to be the correct object also for the spectral theorem for quaternionic normal operators. The lack of a suitable notion ofmore » spectrum was a major obstruction to fully understand the spectral theorem for quaternionic normal operators. A prime motivation for studying the spectral theorem for quaternionic unbounded normal operators is given by the subclass of unbounded anti-self adjoint quaternionic operators which play a crucial role in the quaternionic quantum mechanics.« less
Extended test of a xenon hollow cathode for a space plasma contactor
NASA Technical Reports Server (NTRS)
Sarver-Verhey, Timothy R.
1994-01-01
Implementation of a hollow cathode plasma contactor for charge control on the Space Station has required validation of long-life hollow cathodes. A test series of hollow cathodes and hollow cathode plasma contactors was initiated as part of the plasma contactor development program. An on-going wear-test of a hollow cathode has demonstrated cathode operation in excess of 4700 hours with small changes in operating parameters. The discharge experienced 4 shutdowns during the test, all of which were due to test facility failures or expellant replenishment. In all cases, the cathode was reignited at approximately 42 volts and resumed typical operation. This test represents the longest demonstrated stable operation of a high current (greater than 1A) xenon hollow cathode reported to date.
Continuing life test of a xenon hollow cathode for a space plasma contactor
NASA Technical Reports Server (NTRS)
Sarver-Verhey, Timothy R.
1994-01-01
Implementation of a hollow cathode plasma contactor for charge control on the Space Station has required validation of long-life hollow cathodes. A test series of hollow cathodes and hollow cathode plasma contactors was initiated as part of the plasma contactor development program. An on-going wear-test of a hollow cathode has demonstrated cathode operation in excess of 10,000 hours with small changes in operating parameters. The discharge has experienced 10 shutdowns during the test, all of which were due to test facility failures or expellant replenishment. In all cases, the cathode was re-ignited at approximately 42 volts and resumed typical operation. This test represents the longest demonstrated stable operation of a high current (greater than 1 A) xenon hollow cathode reported to date.
NASA Astrophysics Data System (ADS)
Nishiyama, H.; Onodera, M.; Igawa, J.; Nakajima, T.
2009-12-01
The aim of this study is to provide the optimum operating conditions for enhancing in-flight alumina particle heating as much as possible for particle spheroidization and aggregation of melted particles using a DC-RF hybrid plasma flow system even at constant low operating power based on the thermofluid considerations. It is clarified that the swirl flow and higher operating pressure enhance the particle melting and aggregation of melted particles coupled with increasing gas temperature downstream of a plasma uniformly in the radial direction at constant electrical discharge conditions.
How Does Plasma Activated Media Treatment Differ From Direct Cold Plasma Treatment.
Attri, Pankaj; Park, Ji Hoon; Ali, Anser; Choi, Eun Ha
2018-04-06
The aim of the paper is to investigate the optimum condition for generation of plasma activated media (PAM), where it can deactivate the cancer cells while minimum damage for normal cells. Over past few years, cold atmospheric plasma-activated media (PAM) have shown its promising application in plasma medicine for treatment of cancer. PAM has a tremendous ability for selective anti-cancer capacity in vitro and in vivo. We have analyzed the radicals in air using the optical emission spectroscopy and in culture media using chemical analysis. Further, we have tested the toxicity of PAM using MTT assay. We observed that more cancer cell death is for the Ar plasma followed by the Ar-N2 plasma, and the least cell death was observed for the Ar-O2 plasma at all treatment times both by direct treatment and through PAM treatment. The concentration of the RNS species is high for Ar-N2 plasma in gas as well as inside the culture media compared to that for pure Ar plasma. However, the difference is significantly less between the Ar plasma treatments and the Ar-N2 plasma treatments, showing that ROS is the main factor contributing to cell death. Among all three feeding gas plasmas the best system is Ar-O2 plasma for direct treatments towards the cancer cells. In addition, the best system for PAM preparation is Ar-N2 at low time treatments (1 min and 2 min) because it has no effect on normal cells, but kills the cancer cells. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.
NASA Astrophysics Data System (ADS)
Krauz, V. I.; Myalton, V. V.; Vinogradov, V. P.; Velikhov, E. P.; Ananyev, S. S.; Dan'ko, S. A.; Kalinin, Yu G.; Kharrasov, A. M.; Vinogradova, Yu V.; Mitrofanov, K. N.; Paduch, M.; Miklaszewski, R.; Zielinska, E.; Skladnik-Sadowska, E.; Sadowski, M. J.; Kwiatkowski, R.; Tomaszewski, K.; Vojtenko, D. A.
2017-10-01
Results are presented from laboratory simulations of plasma jets emitted by young stellar objects carried out at the plasma focus facilities. The experiments were performed at three facilities: the PF-3, PF-1000U and KPF-4. The operation modes were realized enabling the formation of narrow plasma jets which can propagate over long distances. The main parameters of plasma jets and background plasma were determined. In order to control the ratio of a jet density to that of background plasma, some special operation modes with pulsed injection of the working gas were used.
Investigations on the heat flux and impurity for the HL-2M divertor
NASA Astrophysics Data System (ADS)
Zheng, G. Y.; Cai, L. Z.; Duan, X. R.; Xu, X. Q.; Ryutov, D. D.; Cai, L. J.; Liu, X.; Li, J. X.; Pan, Y. D.
2016-12-01
The controllability of the heat load and impurity in the divertor is very important, which could be one of the critical problems to be solved in order to ensure the success for a steady state tokamak. HL-2M has the advantage of the poloidal field (PF) coils placed inside the demountable toroidal field (TF) coils and close to the main plasma. As a result, it is possible to make highly accurate configuration control of the advanced divertor for HL-2M. The divertor target geometry of HL-2M has been designed to be compatible with different divertor configurations to study the divertor physics and support the high performance plasma operations. In this paper, the heat loads and impurities with different divertor configurations, including the standard X-point divertor, the snowflake-minus divertor and two tripod divertor configurations for HL-2M, are investigated by numerical simulations with the SOLPS5.0 code under the current design of the HL-2M divertor geometry. The plasmas with different conditions, such as the low discharge parameters with {{I}\\text{p}} = 0.5 MA at the first stage of HL-2M and the high parameters with {{I}\\text{p}} = 2.0 MA during the normal operations, are simulated. The heat load profiles and the impurity distributions are obtained, and the control of the peak heat load and the effect of impurity on the core plasma are discussed. The compatibility of different divertor configurations for HL-2M is also evaluated. It is seen that the excellent compatibility of different divertor configurations with the current divertor geometry has been verified. The results show that the snowflake-minus divertor and the tripod divertor with {{d}x}=30 \\text{cm} present good performance in terms of the heat load profiles and the impurity distributions under different conditions, which may not have a big effect on the core plasma. In addition, it is possible to optimize the distance between the two X-points, {{d}x} , to achieve a better performance in terms of the parameters of discharges.
NASA Astrophysics Data System (ADS)
Kim, S. H.; Casper, T. A.; Snipes, J. A.
2018-05-01
ITER will demonstrate the feasibility of burning plasma operation by operating DT plasmas in the ELMy H-mode regime with a high ratio of fusion power gain Q ~ 10. 15 MA ITER baseline operation scenario has been studied using CORSICA, focusing on the entry to burn, flat-top burning plasma operation and exit from burn. The burning plasma operation for about 400 s of the current flat-top was achieved in H-mode within the various engineering constraints imposed by the poloidal field coil and power supply systems. The target fusion gain (Q ~ 10) was achievable in the 15 MA ITER baseline operation with a moderate amount of the total auxiliary heating power (~50 MW). It has been observed that the tungsten (W) concentration needs to be maintained low level (n w/n e up to the order of 1.0 × 10-5) to avoid the radiative collapse and uncontrolled early termination of the discharge. The dynamic evolution of the density can modify the H-mode access unless the applied auxiliary heating power is significantly higher than the H-mode threshold power. Several qualitative sensitivity studies have been performed to provide guidance for further optimizing the plasma operation and performance. Increasing the density profile peaking factor was quite effective in increasing the alpha particle self-heating power and fusion power multiplication factor. Varying the combination of auxiliary heating power has shown that the fusion power multiplication factor can be reduced along with the increase in the total auxiliary heating power. As the 15 MA ITER baseline operation scenario requires full capacity of the coil and power supply systems, the operation window for H-mode access and shape modification was narrow. The updated ITER baseline operation scenarios developed in this work will become a basis for further optimization studies necessary along with the improvement in understanding the burning plasma physics.
Plasma source development for fusion-relevant material testing
Caughman, John B. O.; Goulding, Richard H.; Biewer, Theodore M.; ...
2017-05-01
Plasma facing materials in the divertor of a magnetic fusion reactor will have to tolerate steady-state plasma heat fluxes in the range of 10 MW/m2 for ~107 sec, in addition to fusion neutron fluences, which can damage the plasma facing materials to high displacements per atom (dpa) of ~50 dpa . Material solutions needed for the plasma facing components are yet to be developed and tested. The Materials Plasma Exposure eXperiment (MPEX) is a newly proposed steady state linear plasma device that is designed to deliver the necessary plasma heat flux to a target for this material testing, including themore » capability to expose a-priori neutron damaged material samples to those plasmas. The requirements of the plasma source needed to deliver this plasma heat flux are being developed on the Proto-MPEX device, which is a linear high-intensity radio frequency (RF) plasma source that combines a high-density helicon plasma generator with electron and ion heating sections. It is being used to study the physics of heating over-dense plasmas in a linear configuration. The helicon plasma is operated at 13.56 MHz with RF power levels up to 120 kW. Microwaves at 28 GHz (~30 kW) are coupled to the electrons in the over-dense helicon plasma via Electron Bernstein Waves (EBW), and ion cyclotron heating at 7-9 MHz (~30 kW) is via a magnetic beach approach. High plasma densities >6x1019/m3 have been produced in deuterium, with electron temperatures that can range from 2 to >10 eV. Operation with on-axis magnetic field strengths between 0.6 and 1.4 T is typical. The plasma heat flux delivered to a target can be > 10 MW/m2, depending on the operating conditions.« less
Plasma source development for fusion-relevant material testing
DOE Office of Scientific and Technical Information (OSTI.GOV)
Caughman, John B. O.; Goulding, Richard H.; Biewer, Theodore M.
Plasma facing materials in the divertor of a magnetic fusion reactor will have to tolerate steady-state plasma heat fluxes in the range of 10 MW/m2 for ~107 sec, in addition to fusion neutron fluences, which can damage the plasma facing materials to high displacements per atom (dpa) of ~50 dpa . Material solutions needed for the plasma facing components are yet to be developed and tested. The Materials Plasma Exposure eXperiment (MPEX) is a newly proposed steady state linear plasma device that is designed to deliver the necessary plasma heat flux to a target for this material testing, including themore » capability to expose a-priori neutron damaged material samples to those plasmas. The requirements of the plasma source needed to deliver this plasma heat flux are being developed on the Proto-MPEX device, which is a linear high-intensity radio frequency (RF) plasma source that combines a high-density helicon plasma generator with electron and ion heating sections. It is being used to study the physics of heating over-dense plasmas in a linear configuration. The helicon plasma is operated at 13.56 MHz with RF power levels up to 120 kW. Microwaves at 28 GHz (~30 kW) are coupled to the electrons in the over-dense helicon plasma via Electron Bernstein Waves (EBW), and ion cyclotron heating at 7-9 MHz (~30 kW) is via a magnetic beach approach. High plasma densities >6x1019/m3 have been produced in deuterium, with electron temperatures that can range from 2 to >10 eV. Operation with on-axis magnetic field strengths between 0.6 and 1.4 T is typical. The plasma heat flux delivered to a target can be > 10 MW/m2, depending on the operating conditions.« less
Aleryani, Samir Lutf; Cluette-Brown, Joanne E; Khan, Zia A; Hasaba, Hasan; Lopez de Heredia, Luis; Laposata, Michael
2005-09-01
Methanol is a component of certain alcoholic beverages and is also an endogenously formed product. On this basis, we have proposed that methanol may promote synthesis of fatty acid methyl esters (FAMEs) in the same way that ethanol promotes fatty acid ethyl ester (FAEE) synthesis. We tested the hypothesis that FAMEs appear in the blood after ethanol intake. Patient plasma samples obtained from our laboratory (n=78) were grouped according to blood ethanol concentrations (intoxicated, blood ethanol >800 mg/l) and non-intoxicated. These samples were further subdivided into groups based on whether the patient had normal or abnormal liver function tests (abnormal, defined as > or =1 abnormality of plasma alanine and aspartate aminotransferase, albumin, total bilirubin, and alkaline phosphatase). A separate set of plasma samples were also divided into normal and abnormal groups based on pancreatic function tests (amylase and lipase). There were no patients with detectable ethanol in this group. Patients with abnormalities in pancreatic function tests were included upon recognition of endogenously produced FAMEs by patients with liver function test abnormalities. FAMEs were extracted from plasma and individual species of FAMEs quantified by gas chromatography-mass spectrometry (GC/MS). Increased concentrations of FAME were found in patient samples with evidence of liver dysfunction, regardless of whether or not they were intoxicated (n=21, p=0.01). No significant differences in plasma FAME concentrations were found between patients with normal (n=15) versus abnormal pancreatic function tests (n=22, p=0.72). The presence of FAMEs in human plasma may be related to the existence of liver disease, and not to blood ethanol concentrations or pancreatic dysfunction. The metabolic pathways associated with FAME production in patients with impaired liver function remain to be identified.
Arnold, W. David; Duque, Sandra; Iyer, Chitra C.; Zaworski, Phillip; McGovern, Vicki L.; Taylor, Shannon J.; von Herrmann, Katharine M.; Kobayashi, Dione T.; Chen, Karen S.; Kolb, Stephen J.; Paushkin, Sergey V.; Burghes, Arthur H. M.
2016-01-01
Introduction and Objective Spinal muscular atrophy (SMA) is an autosomal recessive motor neuron disorder. SMA is caused by homozygous loss of the SMN1 gene and retention of the SMN2 gene resulting in reduced levels of full length SMN protein that are insufficient for motor neuron function. Various treatments that restore levels of SMN are currently in clinical trials and biomarkers are needed to determine the response to treatment. Here, we sought to investigate in SMA mice a set of plasma analytes, previously identified in patients with SMA to correlate with motor function. The goal was to determine whether levels of plasma markers were altered in the SMNΔ7 mouse model of SMA and whether postnatal SMN restoration resulted in normalization of the biomarkers. Methods SMNΔ7 and control mice were treated with antisense oligonucleotides (ASO) targeting ISS-N1 to increase SMN protein from SMN2 or scramble ASO (sham treatment) via intracerebroventricular injection on postnatal day 1 (P1). Brain, spinal cord, quadriceps muscle, and liver were analyzed for SMN protein levels at P12 and P90. Ten plasma biomarkers (a subset of biomarkers in the SMA-MAP panel available for analysis in mice) were analyzed in plasma obtained at P12, P30, and P90. Results Of the eight plasma biomarkers assessed, 5 were significantly changed in sham treated SMNΔ7 mice compared to control mice and were normalized in SMNΔ7 mice treated with ASO. Conclusion This study defines a subset of the SMA-MAP plasma biomarker panel that is abnormal in the most commonly used mouse model of SMA. Furthermore, some of these markers are responsive to postnatal SMN restoration. These findings support continued clinical development of these potential prognostic and pharmacodynamic biomarkers. PMID:27907033
Chatterjee, Pratishtha; Goozee, Kathryn; Sohrabi, Hamid R; Shen, Kaikai; Shah, Tejal; Asih, Prita R; Dave, Preeti; ManYan, Candice; Taddei, Kevin; Chung, Roger; Zetterberg, Henrik; Blennow, Kaj; Martins, Ralph N
2018-01-01
The disruption of neurofilament, an axonal cytoskeletal protein, in neurodegenerative conditions may result in neuronal damage and its release into the cerebrospinal fluid and blood. In Alzheimer's disease (AD), neurofilament light chain (NFL), a neurofilament subunit, is elevated in the cerebrospinal fluid and blood. Investigate the association of plasma NFL with preclinical-AD features, such as high neocortical amyloid-β load (NAL) and subjective memory complaints, and cognitive performance in cognitively normal older adults. Plasma NFL concentrations were measured employing the single molecule array platform in participants from the Kerr Anglican Retirement Village Initiative in Ageing Health cohort, aged 65- 90 years. Participants underwent a battery of neuropsychological testing to evaluate cognitive performance and were categorized as low NAL (NAL-, n = 65) and high NAL (NAL+, n = 35) assessed via PET, and further stratified into subjective memory complainers (SMC; nNAL- = 51, nNAL+ = 25) and non-SMC (nNAL- = 14, nNAL+ = 10) based on the Memory Assessment Clinic- Questionnaire. Plasma NFL inversely correlated with cognitive performance. No significant difference in NFL was observed between NAL+ and NAL- participants; however, within APOEɛ4 non-carriers, higher NAL was observed in individuals with NFL concentrations within quartiles 3 and 4 (versus quartile 1). Additionally, within the NAL+ participants, SMC had a trend of higher NFL compared to non-SMC. Plasma NFL is inversely associated with cognitive performance in elderly individuals. While plasma NFL may not reflect NAL in individuals with normal global cognition, the current observations indicate that onset of axonal injury, reflected by increased plasma NFL, within the preclinical phase of AD may contribute to the pathogenesis of AD.
Li, Hong-mian; Liang, Zi-qian; Luo, Zuo-jie
2003-06-01
To investigate the postburn dynamic changes in the hypothalamus-pituitary-adrenal hormones in severely burned patients. Fifty burn patients were enrolled in the study. The plasma contents of total GC (cortisol), ACTH and aldosterone (ALDO) and urinary contents of 17-OHO and 17-KS were determined with radio-immunological assay (RIA) method after burn injury to compare with the normal values which were well established clinically. The postburn plasma and urinary contents of the above indices were increased evidently with two peak values in shock and infectious stages, whilst the majority of he indices were lower than the normal values after 6 postburn weeks (PBWs). The values of these hormones were the lowest in dying patients. On the other hand, the values approached normal levels in those patients whose burn wounds were healing. Increases of the plasma and urinary levels of hypothalamus-pituitary -adrenal hormones in severely burned patients were constantly seen. Burn shock and infection seemed to be the two major factors in inducing postburn stress reaction in burn victims. Abrupt decrease of the hormone levels in plasma and or urine indicated adrenal failure predicting a poor prognosis of the burn patients.
Mackey, S A; Berlin, C M
1992-07-01
Six normal subjects each ingested a single 12-oz can of a diet cola (Diet Coke) providing 184 mg aspartame (APM), of which 104 mg is phenylalanine (Phe), and, on another occasion, a single 12-oz can of regular cola (Coke Classic). Neither cola significantly affected plasma concentrations of Phe or tyrosine over the three-hour postingestion study period. Each of five homozygous phenylketonuric (PKU) subjects (ages 11, 16, 17, 21, and 23 years) ingested a single 12-oz can of the same diet cola. In these five subjects (three with classic PKU and two with hyperphenylalinemia), the increase in plasma Phe concentrations varied from 0.26 mg/dL to 1.77 mg/dL two or three hours after ingestion (baseline levels, 5.04 to 17.2 mg/dL). Tyrosine concentrations did not differ significantly from baseline levels. The data indicate that ingestion of dietary Phe, as supplied in a single can of diet cola, is readily handled in both normal and PKU subjects. The small increases in plasma Phe concentrations in the homozygous PKU patients are not considered clinically significant.
Integrated modelling of steady-state scenarios and heating and current drive mixes for ITER
DOE Office of Scientific and Technical Information (OSTI.GOV)
Murakami, Masanori; Park, Jin Myung; Giruzzi, G.
2011-01-01
Recent progress on ITER steady-state (SS) scenario modelling by the ITPA-IOS group is reviewed. Code-to-code benchmarks as the IOS group's common activities for the two SS scenarios (weak shear scenario and internal transport barrier scenario) are discussed in terms of transport, kinetic profiles, and heating and current drive (CD) sources using various transport codes. Weak magnetic shear scenarios integrate the plasma core and edge by combining a theory-based transport model (GLF23) with scaled experimental boundary profiles. The edge profiles (at normalized radius rho = 0.8-1.0) are adopted from an edge-localized mode-averaged analysis of a DIII-D ITER demonstration discharge. A fullymore » noninductive SS scenario is achieved with fusion gain Q = 4.3, noninductive fraction f(NI) = 100%, bootstrap current fraction f(BS) = 63% and normalized beta beta(N) = 2.7 at plasma current I(p) = 8MA and toroidal field B(T) = 5.3 T using ITER day-1 heating and CD capability. Substantial uncertainties come from outside the radius of setting the boundary conditions (rho = 0.8). The present simulation assumed that beta(N)(rho) at the top of the pedestal (rho = 0.91) is about 25% above the peeling-ballooning threshold. ITER will have a challenge to achieve the boundary, considering different operating conditions (T(e)/T(i) approximate to 1 and density peaking). Overall, the experimentally scaled edge is an optimistic side of the prediction. A number of SS scenarios with different heating and CD mixes in a wide range of conditions were explored by exploiting the weak-shear steady-state solution procedure with the GLF23 transport model and the scaled experimental edge. The results are also presented in the operation space for DT neutron power versus stationary burn pulse duration with assumed poloidal flux availability at the beginning of stationary burn, indicating that the long pulse operation goal (3000s) at I(p) = 9 MA is possible. Source calculations in these simulations have been revised for electron cyclotron current drive including parallel momentum conservation effects and for neutral beam current drive with finite orbit and magnetic pitch effects.« less
LARGE—A Plasma Torch for Surface Chemistry Applications and CVD Processes—A Status Report
NASA Astrophysics Data System (ADS)
Zimmermann, Stephan; Theophile, Eckart; Landes, Klaus; Schein, Jochen
2008-12-01
The LARGE ( LONG ARG GENERATOR) is a new generation DC-plasma torch featuring an extended arc which is operated with a perpendicular gas flow to create a wide (up to 45 cm) plasma jet well suited for large area plasma processing. Using plasma diagnostic systems like high speed imaging, enthalpy probe, emission spectroscopy, and tomography, the LARGE produced plasma jet characteristics have been measured and sources of instability have been identified. With a simple model/simulation of the system LARGE III-150 and numerous experimental results, a new nozzle configuration and geometry (LARGE IV-150) has been designed, which produces a more homogenous plasma jet. These improvements enable the standard applications of the LARGE plasma torch (CVD coating process and surface activation process) to operate with higher efficiency.
Luzanova, I S; Svetlolobov, D Iu; Zorin, Iu V
2014-01-01
The objective of the present work was to continue the studies of the sites of concentration of the chemical elements corresponding to normal homeostasis in human biological objects by mass spectrometry with inductively coupled plasma. The study yielded the data on the natural content of 27 elements in the cadaveric liver, kidney, and stomach. It is recommended to use these findings as the reference parameters corresponding to normal homeostasis.
Development of RF Sensor Based on Two-Cell Squid
2011-07-15
to (8) is proportional to the reduced drive detuning, ωp0 is the resonant frequency for small oscillations, i.e. the plasma frequency of the combined...2 Φ= cnc IRπω (16) where Rn is the normal resistance of the Josephson junction in the SQUID, and L the inductance of the...were about 9 fF. The critical current I0 of each junction in the SQUID was 17.7 μA, normal resistance 110.9 Ω, plasma frequency ωp 124 GHz and
Development of RF Sensor Based on Two-cell SQUID
2012-07-01
according to (8) is proportional to the reduced drive detuning, ωp0 is the resonant frequency for small oscillations, i.e. the plasma frequency of the...0/2 Φ= cnc IRπω (16) where Rn is the normal resistance of the Josephson junction in the SQUID, and L the inductance of the...17.7 μA, normal resistance 110.9 Ω, plasma frequency ωp 124 GHz and characteristic frequency 948 GHz. While the loop inductance of SQUID was 60 pH
Plasma diamine oxidase levels in pregnancy complicated by threatened abortion.
Legge, M; Duff, G B
1981-01-01
Plasma diamine oxidase levels were assayed in 66 patients who presented with pregnancy complicated by threatened abortion. Levels within the normal range were associated with continuing pregnancies, whereas levels below the normal range were associated with subsequent abortion. Among those patients in whom gestation was greater than eight weeks, 66.6% of diamine oxidase levels correctly predicted the pregnancy outcome. Assay of the diamine oxidase levels at eight weeks of gestation or less gave little useful information. PMID:6785320
Mantzoros, C; Flier, J S; Lesem, M D; Brewerton, T D; Jimerson, D C
1997-06-01
Studies in rodents have shown that leptin acts in the central nervous system to modulate food intake and energy metabolism. To evaluate the possible role of leptin in the weight loss of anorexia nervosa, this study compared cerebrospinal fluid (CSF) and plasma leptin concentrations in anorexic patients and controls. Subjects included 11 female patients with anorexia nervosa studied at low weight and after treatment, and 15 healthy female controls. Concentrations of leptin in blood and CSF were measured by RIA. Patients with anorexia nervosa, compared to controls, had decreased concentrations of leptin in CSF (98 +/- 26 vs. 160 +/- 58 pg/mL; P < 0.0005) and plasma (1.75 +/- 0.46 vs. 7.01 +/- 3.92 ng/mL; P < 0.005). The CSF to plasma leptin ratio, however, was higher for patients (0.060 +/- 0.023) than for controls (0.025 +/- 0.007; P < 0.0001). At posttreatment testing, although patients had not yet reached normal body weight, CSF and plasma leptin concentrations had increased to normal levels. These results demonstrate the dynamic changes in plasma and CSF leptin during positive energy balance in anorexia nervosa. The results further suggest that normalization of CSF leptin levels before full weight restoration during treatment of anorexic patients could contribute to resistance to weight gain and/or incomplete weight recovery.
Goldsmith, G H; Pence, R E; Ratnoff, O D; Adelstein, D J; Furie, B
1982-01-01
Two siblings with m ild hemorrhagic symptoms had combined functional deficiencies of vitamin K-dependent clotting factors. Prothrombin (0.18-0.20 U/ml) and Stuart factor (Factor X, 0.18-0.20 U/ml) and Stuart factor (Factor X, 0.18-0.20 U/ml) were most severely affected. Antigenic amounts of affected coagulation factors were normal and normal generation of thrombin activity occurred in the patients' plasmas after treatment with nonophysiologic activators that do not require calcium for prothrombin activation. Hepatobilary disease, malabsorptive disorders, and plasma warfarin were not present. Both parents had normal levels of all coagulation factors. The patients' plasmas contained prothrombin that reacted both with antibody directed against des-gamma-carboxyprothrombin and native prothrombin. Crossed immunoelectrophoresis of patients' plasmas and studies of partially purified patient prothrombin suggested the presence of a relatively homogeneous species of dysfunctional prothrombin, distinct from the heterologous species found in the plasma of warfarin-treated persons. These studies are most consistent with a posttranslational defect in hepatic carboxylation of vitamin K-dependent factors. This kindred uniquely possesses an autosomal recessive disorder of vitamin K-dependent factor formation that causes production of an apparently homogeneous species of dysfunctional prothrombin; the functional deficiencies in clotting factors are totally corrected by oral or parenteral administration of vitamin K1. Images PMID:7085873
Nielsen, Vance G; Matika, Ryan W; Ley, Michele L B; Waer, Amy L; Gharagozloo, Farid; Kim, Samuel; Nfonsam, Valentine N; Ong, Evan S; Jie, Tun; Warneke, James A; Steinbrenner, Evangelina B
2014-04-01
Although cancer-mediated changes in hemostatic proteins unquestionably promote hypercoagulation, the effects of neoplasia on fibrinolysis in the circulation are less well defined. The goals of the present investigation were to determine if plasma obtained from patients with breast, lung, pancreas and colon cancer was less or more susceptible to lysis by tissue-type plasminogen activator (tPA) compared to plasma obtained from normal individuals. Archived plasma obtained from patients with breast (n = 18), colon/pancreas (n = 27) or lung (n = 19) was compared to normal individual plasma (n = 30) using a thrombelastographic assay that assessed fibrinolytic vulnerability to exogenously added tPA. Plasma samples were activated with tissue factor/celite, had tPA added, and had data collected until clot lysis occurred. Additional, similar samples had potato carboxypeptidase inhibitor added to assess the role played by thrombin-activatable fibrinolysis inhibitor in cancer-modulated fibrinolysis. Rather than inflicting a hypofibrinolytic state, the three groups of cancers demonstrated increased vulnerability to tPA (e.g. decreased time to lysis, increased speed of lysis, decreased clot lysis time). However, hypercoagulation manifested as increased speed of clot formation and strength compensated for enhanced fibrinolytic vulnerability, resulting in a clot residence time that was not different from normal individual thrombi. In sum, enhanced hypercoagulability associated with cancer was in part diminished by enhanced fibrinolytic vulnerability to tPA.
Plasma and muscle cortisol measurements as indicators of meat quality and stress in pigs.
Shaw, F D; Trout, G R; McPhee, C P
1995-01-01
Post-slaughter blood samples and muscle samples were collected from pigs slaughtered at the completion of a live-animal performance trial. There were two lines of pigs in which the halothane allele (n) was segregating. The lines were a lean line selected for rapid lean growth and an unselected fat line. There were homozygous normal (NN), homozygous halothane positive (nn) and heterozygous (Nn) genotypes in both lnes. Cortisol was measured in the plasma of the blood samples and in muscle juice obtained by high-speed centrifugation. Meat quality was assessed using pH, colour, fibre-optic probe, drip loss and cure yield measurements. Plasma cortisol concentrations in the fat line were significantly (P < 0·05) greater than thosein the lean line but concentrations did not differ significantly for the three halothane genotypes. Carcasses classified as dark, firm and dry (DFD) had significantly (P < 0·05) greater muscle cortisol concentrations than those classified as normal. Plasma and muscle cortisol concentrations of carcases classified as pale, soft and exudative (PSE) did not differ significantly from those classified as normal. Correlations between muscle cortisol and meat quality attributes were generally highly significant (r = 0·31 to r = 0·51, P < 0·001) There was a highly significant correlation (r = 0·73, P < 0·0001) between plasma and muscle cortisol concentrations.
Ripple formation on Si surfaces during plasma etching in Cl2
NASA Astrophysics Data System (ADS)
Nakazaki, Nobuya; Matsumoto, Haruka; Sonobe, Soma; Hatsuse, Takumi; Tsuda, Hirotaka; Takao, Yoshinori; Eriguchi, Koji; Ono, Kouichi
2018-05-01
Nanoscale surface roughening and ripple formation in response to ion incidence angle has been investigated during inductively coupled plasma etching of Si in Cl2, using sheath control plates to achieve the off-normal ion incidence on blank substrate surfaces. The sheath control plate consisted of an array of inclined trenches, being set into place on the rf-biased electrode, where their widths and depths were chosen in such a way that the sheath edge was pushed out of the trenches. The distortion of potential distributions and the consequent deflection of ion trajectories above and in the trenches were then analyzed based on electrostatic particle-in-cell simulations of the plasma sheath, to evaluate the angular distributions of ion fluxes incident on substrates pasted on sidewalls and/or at the bottom of the trenches. Experiments showed well-defined periodic sawtooth-like ripples with their wave vector oriented parallel to the direction of ion incidence at intermediate off-normal angles, while relatively weak corrugations or ripplelike structures with the wave vector perpendicular to it at high off-normal angles. Possible mechanisms for the formation of surface ripples during plasma etching are discussed with the help of Monte Carlo simulations of plasma-surface interactions and feature profile evolution. The results indicate the possibility of providing an alternative to ion beam sputtering for self-organized formation of ordered surface nanostructures.
Operational Characteristics of a High Voltage Dense Plasma Focus.
1985-11-01
A high voltage dense plasma focus powered by a single-stage Marx bank was designed, built and operated. The maximum bank parameters are: voltage--120...kV, energy--20 kJ, short-circuit current--600kA. The bank impedance is about 200 millohms. The plasma focus center electrode diameter is 1.27 cm. The...about 50 milliohms. The context of this work is established with a review of previous plasma focus theoretical, experimental and computational work and
Tanajak, Pongpan; Pongkan, Wanpitak; Chattipakorn, Siriporn C; Chattipakorn, Nipon
2018-05-01
Propose: To investigate the temporal relationship between plasma fibroblast growth factor 21 levels, insulin resistance, metabolic dysfunction and cardiac fibroblast growth factor 21 resistance in long-term high-fat diet-induced obese rats. In total, 36 male Wistar rats were fed with either a normal diet or high-fat diet for 12 weeks. Blood was collected from the tail tip, and plasma was used to determine metabolic profiles and fibroblast growth factor 21 levels. Rats were sacrificed at weeks 4, 8 and 12, and the hearts were rapidly removed for the determination of cardiac fibroblast growth factor 21 signalling pathways. Body weight and plasma fibroblast growth factor 21 levels were increased after 4 weeks of consumption of a high-fat diet. At weeks 8 and 12, high-fat diet rats had significantly increased body weight and plasma fibroblast growth factor 21 levels, together with increased plasma insulin, HOMA index, area under the curve of glucose, plasma total cholesterol, plasma low-density lipoprotein cholesterol, serum malondialdehyde and cardiac malondialdehyde levels. However, plasma high-density lipoprotein cholesterol levels and cardiac fibroblast growth factor 21 signalling proteins (p-FGFR1 Tyr 154 , p-ERK1/2 Thr 202 /Tyr 204 and p-Akt Ser 473 ) were decreased, compared with normal diet rats. These findings suggest that plasma fibroblast growth factor 21 levels could be an early predictive biomarker prior to the development of insulin resistance, metabolic disturbance and cardiac fibroblast growth factor 21 resistance.
Robertson, Gary L.; Mahr, Ermelinda A.; Athar, Shahid; Sinha, Tushar
1973-01-01
A radioimmunoassay has been developed that permits reliable measurements of plasma arginine vasopressin (AVP) at concentrations as low as 0.5 pg/ml in sample volumes of 1 ml or less. Nonhormonal immunoreactivity associated with the plasma proteins is eliminated by acetone precipitation before assay, leaving unaltered a component that is immunologically and chromatographically indistinguishable from standard AVP. Storage of plasma results in a decline in AVP concentration and, thus, must be carefully regulated. The plasma AVP values obtained by our method approximate the anticipated levels and vary in accordance with physiologic expections. In recumbent normal subjects, plasma AVP ranged from (mean ±SD) 5.4±3.4 pg/ml after fluid deprivation to 1.4±0.8 pg/ml after water loading, and correlated significantly with both plasma osmolality (r=0.52; P<0.001) and urine osmolality (r=0.77; P<0.001). After fluid restriction, plasma AVP was uniformly normal relative to plasma osmolality in patients with nephrogenic diabetes insipidus and primary polydipsia but was distinctly subnormal in all patients with pituitary diabetes insipidus. The infusion of physiologic amounts of posterior pituitary extract caused a dose-related rise in plasma vasopressin that afterwards declined at the expected rate (t½=22.5±4 min). We conclude that, when used appropriately, our radioimmunoassay method provides a useful way of assessing AVP function in man. PMID:4727463
Imposed, ordered dust structures and other plasma features in a strongly magnetized plasma
NASA Astrophysics Data System (ADS)
Thomas, Edward; Leblanc, Spencer; Lynch, Brian; Konopka, Uwe; Merlino, Robert; Rosenberg, Marlene
2015-11-01
The Magnetized Dusty Plasma Experiment (MDPX) device has been in operation for just over one year. In that time, the MDPX device has been operating using a uniform magnetic field configuration up to 3.0 Tesla and has successfully produced plasmas and dusty plasmas at high magnetic fields. In these experimental studies, we have made observations of a new type of imposed, ordered structure in a dusty plasma at magnetic fields above 1 T. These dusty plasma structures are shown to scale inversely with neutral pressure and are shown to reflect the spatial structure of a wire mesh placed in the plasma. Additionally, recent measurements have been made that give insights into the effective potential that establishes the ordered structures in the plasma. In this presentation, we report on details of the imposed, ordered dusty plasma structure as well as filamentary features that also appear in the plasma and modify the confinement of the dusty plasma. This work is supported with funding from the NSF and Department of Energy.
High Current Hollow Cathode Plasma Plume Measurements
NASA Technical Reports Server (NTRS)
Thomas, Robert E.; Kamhawi, Hani; Williams, George J., Jr.
2014-01-01
Plasma plume measurements are reported for a hollow cathode assembly (HCA) operated at discharge currents of 50, 70, and 100 A at xenon flow rates between 19 - 46 standard cubic centimeter per minute. The HCA was centrally mounted in the NASA-300MS Hall Thruster and was operated in the "spot" and "plume" modes with additional data taken with an applied magnetic field. Langmuir probes, retarding potential analyzers, and optical emission spectroscopy were employed to measure plasma properties near the orifice of the HCA and to assess the charge state of the near-field plasma. Electron temperatures (2-6 electron volt) and plasma potentials are consistent with probe-measured values in previous investigations. Operation with an applied-field yields higher discharge voltages, increased Xe III production, and increased signals from the 833.5 nm C I line. While operating in plume mode and with an applied field, ion energy distribution measurements yield ions with energies significantly exceeding the applied discharge voltage. These findings are correlated with high-frequency oscillations associated with each mode.
Meyer, Matthew J; Dzik, Walter H; Levine, Wilton C
2017-02-01
Blood product transfusion is the most commonly performed hospital procedure. Intraoperative blood product utilization varies between institutions and anesthesiologists. In the United States in 2011, nearly 4 million plasma units were transfused. A retrospective analysis of intraoperative plasma ordering patterns and utilization (thawing and transfusing) was performed at a tertiary, academic hospital between January 2015 and March 2016. Over 15 months, 46,002 operative procedures were performed. In 1540 of them, plasma was thawed or transfused: 8297 plasma units were thawed and 3306 of those units were transfused. These 3306 plasma units were transfused in 749 cases with a median of 2 plasma units (interquartile range, 2-4) transfused. The percentage of average monthly procedures with plasma thawed and none transfused was 51.3% (confidence interval, 49.0%-53.6%). The cardiac surgery service requested the greatest number of plasma units to be thawed (2143) but only transfused 712 (33.2%) of them. Of all plasma units not transfused, 45% were generated by procedures with 1 to 4 units of plasma thawed; 95.7% of these units were thawed as even integers (ie, 2, 4). For operative procedures, far more plasma was thawed than was transfused and this practice occurred across surgical specialties and anesthesiologists. Considering the plasma that was not transfused, 45% occurred in procedures with 4 or fewer units of plasma requested suggesting these low-volume requests were a primary source of potential waste. Further studies are needed to examine associations between plasma utilization and clinical outcomes.
Nonlinear Generation of Electromagnetic Waves through Induced Scattering by Thermal Plasma.
Tejero, E M; Crabtree, C; Blackwell, D D; Amatucci, W E; Mithaiwala, M; Ganguli, G; Rudakov, L
2015-12-09
We demonstrate the conversion of electrostatic pump waves into electromagnetic waves through nonlinear induced scattering by thermal particles in a laboratory plasma. Electrostatic waves in the whistler branch are launched that propagate near the resonance cone. When the amplitude exceeds a threshold ~5 × 10(-6) times the background magnetic field, wave power is scattered below the pump frequency with wave normal angles (~59°), where the scattered wavelength reaches the limits of the plasma column. The scattered wave has a perpendicular wavelength that is an order of magnitude larger than the pump wave and longer than the electron skin depth. The amplitude threshold, scattered frequency spectrum, and scattered wave normal angles are in good agreement with theory. The results may affect the analysis and interpretation of space observations and lead to a comprehensive understanding of the nature of the Earth's plasma environment.
Effect of mental stress on plasma homovanillic acid in healthy human subjects.
Sumiyoshi, T; Yotsutsuji, T; Kurachi, M; Itoh, H; Kurokawa, K; Saitoh, O
1998-07-01
Plasma levels of homovanillic acid (pHVA) have been suggested to provide a measure of dopaminergic activity in the central nervous system. The present study investigated the effect of mental stress by the Kraepelin test, a test of continuous arithmetic addition of single-digit figures for 30 min, on pHVA levels in 13 male psychiatrically normal healthy volunteers. Following an overnight fast and restricted physical activity, plasma samples were collected immediately before and after the administration of the Kraepelin test. Plasma HVA levels following the administration of the Kraepelin test were significantly lower than the pretest pHVA levels. The percent change in pHVA levels by the Kraepelin test positively correlated with pretest pHVA levels. The observed reduction in pHVA levels by mental stress in normal subjects may reflect some aspects of a dopamine-dependent restitutive system in the brain.
Ippoliti, F; Ragno, V; Del Nero, A; McEwen, L M; McEwen, H; Businco, L
1997-05-01
EPD is a method of preventive immunotherapy which employs b-glucuronidase as a biological response modifier. Plasma IL-6 and IL-10 were measured before a single injection of EPD, 24 hours later and 15 days after in a group of 17 children suffering from grass pollen asthma. 17 normal untreated children were used as controls. Although the study was conducted before the grass pollen season when the allergic children were free of symptoms, their plasma IL-6 and IL-10 were significantly elevated before the injection of EPD. 24 hours after treatment the plasma IL-10 had increased significantly and there was also a slight rise in IL-6. 15 days after treatment IL-6 had fallen to normal but IL-10 was still elevated. These findings suggest antigen-specific and non-specific mechanisms by which EPD may produce clinical improvement.
Benzodiazepine sensitivity in normal human subjects.
Hommer, D W; Matsuo, V; Wolkowitz, O; Chrousos, G; Greenblatt, D J; Weingartner, H; Paul, S M
1986-06-01
Increasing intravenous doses of diazepam or placebo were administered to ten healthy normal volunteers, and the changes in saccadic eye velocity, self-rated sedation and anxiety, and plasma cortisol and growth hormone concentrations were measured. Diazepam administration (4.4 to 140 micrograms/kg, cumulative dose) resulted in a dose-dependent decrease in saccadic eye velocity and plasma cortisol level as well as a dose-dependent increase in self-rated sedation and plasma growth hormone level. Self-rated anxiety was unaffected in these relatively nonanxious subjects. The diazepam-induced changes in saccadic eye velocity, sedation, and growth hormone and cortisol levels were highly correlated with each other and with increasing plasma diazepam concentration. These results are consistent with a benzodiazepine receptor-mediated action of diazepam. The highly quantifiable and dose-dependent decrease in saccadic eye velocity by benzodiazepines should make this a useful measure of benzodiazepine receptor sensitivity in humans.
Plasma osmotic changes during major abdominal surgery.
Malone, R A; McLeavey, C A; Arens, J F
1977-12-01
Fluid balance across the capillary membrane is maintained normally by a balance of hydrostatic and colloid osmotic pressures (COP). In 12 patients having major intra-abdominal procedures, the COP was followed during the operative and immediate postoperative periods. The patients' intraoperative fluid management consisted of replacing shed blood with blood and following Shires' concept of crystalloid replacement. Significant decreases in COP to approximately two thirds of the initial value occurred in patients having intra-abdominal procedures versus only a 10 percent decrease in those having peripheral procedures (greater than .001). As a result of this decrease in COP, the balance between hydrostatic and colloid osmotic pressures is lost and risk of pulmonary intersitial edema is increased.
Anderson, Bradley W; Suh, Yun-Suhk; Choi, Boram; Lee, Hyuk-Joon; Yab, Tracy C; Taylor, William; Dukek, Brian A; Berger, Calise K; Cao, Xiaoming; Foote, Patrick H; Devens, Mary E; Boardman, Lisa A; Kisiel, John B; Mahoney, Douglas W; Slettedahl, Seth W; Allawi, Hatim T; Lidgard, Graham P; Smyrk, Thomas C; Yang, Han-Kwang; Ahlquist, David A
2018-05-29
Gastric adenocarcinoma (GAC) is the third most common cause of cancer mortality worldwide. Accurate and affordable non-invasive detection methods have potential value for screening and surveillance. Herein, we identify novel methylated DNA markers (MDMs) for GAC, validate their discrimination for GAC in tissues from geographically separate cohorts, explore marker acquisition through the oncogenic cascade, and describe distributions of candidate MDMs in plasma from GAC cases and normal controls. Following discovery by unbiased whole methylome sequencing, candidate MDMs were validated by blinded methylation-specific PCR in archival case-control tissues from U.S. and South Korean patients. Top MDMs were then assayed by an analytically sensitive method (quantitative real-time allele-specific target and signal amplification) in a blinded pilot study on archival plasma from GAC cases and normal controls. Whole methylome discovery yielded novel and highly discriminant candidate MDMs. In tissue, a panel of candidate MDMs detected GAC in 92-100% of U.S. and S. Korean cohorts at 100% specificity. Levels of most MDMs increased progressively from normal mucosa through metaplasia, adenoma, and GAC with variation in points of greatest marker acquisition. In plasma, a 3 marker panel ( ELMO1 , ZNF569 , C13orf18) detected 86% (95% CI 71-95%) of GACs at 95% specificity. Novel MDMs appear to accurately discriminate GAC from normal controls in both tissue and plasma. The point of aberrant methylation during oncogenesis varies by MDM, which may have relevance to marker selection in clinical applications. Further exploration of these MDMs for GAC screening and surveillance is warranted. Copyright ©2018, American Association for Cancer Research.
Multiorgan insulin sensitivity in lean and obese subjects.
Conte, Caterina; Fabbrini, Elisa; Kars, Marleen; Mittendorfer, Bettina; Patterson, Bruce W; Klein, Samuel
2012-06-01
To provide a comprehensive assessment of multiorgan insulin sensitivity in lean and obese subjects with normal glucose tolerance. The hyperinsulinemic-euglycemic clamp procedure with stable isotopically labeled tracer infusions was performed in 40 obese (BMI 36.2 ± 0.6 kg/m(2), mean ± SEM) and 26 lean (22.5 ± 0.3 kg/m(2)) subjects with normal glucose tolerance. Insulin was infused at different rates to achieve low, medium, and high physiological plasma concentrations. In obese subjects, palmitate and glucose R(a) in plasma decreased with increasing plasma insulin concentrations. The decrease in endogenous glucose R(a) was greater during low-, medium-, and high-dose insulin infusions (69 ± 2, 74 ± 2, and 90 ± 2%) than the suppression of palmitate R(a) (52 ± 4, 68 ± 1, and 79 ± 1%). Insulin-mediated increase in glucose disposal ranged from 24 ± 5% at low to 253 ± 19% at high physiological insulin concentrations. The suppression of palmitate R(a) and glucose R(a) were greater in lean than obese subjects during low-dose insulin infusion but were the same in both groups during high-dose insulin infusion, whereas stimulation of glucose R(d) was greater in lean than obese subjects across the entire physiological range of plasma insulin. Endogenous glucose production and adipose tissue lipolytic rate are both very sensitive to small increases in circulating insulin, whereas stimulation of muscle glucose uptake is minimal until high physiological plasma insulin concentrations are reached. Hyperinsulinemia within the normal physiological range can compensate for both liver and adipose tissue insulin resistance, but not skeletal muscle insulin resistance, in obese people who have normal glucose tolerance.
Aleil, Boris; Meyer, Nicolas; Wolff, Valérie; Kientz, Daniel; Wiesel, Marie-Louise; Gachet, Christian; Cazenave, Jean-Pierre; Lanza, François
2006-10-01
Soluble glycoprotein V (sGPV) is a new plasma marker of thrombosis released from the platelet surface by thrombin. sGPV levels are increased in patients with atherothrombotic diseases, but the determinants of sGPV levels are unknown in the general population. Identification of these potential confounding factors is needed for correct design and analysis of clinical studies on cardiovascular diseases. The aim of this study was to determine the normal range of plasma values and the factors controlling sGPV levels in a population of normal individuals. Three hundred blood donors were recruited at the Etablissement Français du Sang-Alsace for the measurement of plasma levels of sGPV, platelet factor 4 (PF4), thrombin-antithrombin complexes (TAT) and D-dimers. The plasma level of sGPV was (median [interquartile range]) 27.5 [23.5-34.4] microg/l and displayed a Gaussian distribution. sGPV had a lower interindividual coefficient of variation (33%) than PF4 (176%), TAT (87%) or D-dimers (82%). sGPV levels were independent of age and sex but sensitive to red cell (r = 0.412; p < 0.0001) and platelet counts (r = 0.267; p = 0.001), total cholesterol (r = -0.313; p < 0.0001), food intake (r = 0.184; p = 0.0014) and smoking (r = -0.154; p = 0.039). Contrary to PF4 and TAT, sGPV did not differ between venous and arterial blood samples of 12 healthy individuals. Red cell and platelet counts, total cholesterol, current smoking and recent food intake are important determinants of sGPV levels and must be taken into account in clinical studies using sGPV as a thrombosis marker. Normal distribution of sGPV levels in the general population supports its use in clinical applications.
Wang, Xin; Athayde, Neil; Trudinger, Brian
2002-07-01
To test the hypothesis that local production with spill into the fetal circulation of factor(s) injurious to endothelium is responsible for the vascular pathology present when the umbilical artery Doppler study is abnormal. Expression of adhesion molecules is a feature of endothelial cell activation. Case-control study. University teaching hospital. Fetal plasma was collected from 27 normal pregnancies, 39 pregnancies with umbilical placental vascular disease defined by abnormal umbilical artery Doppler and 11 pregnancies with pre-eclampsia and normal umbilical artery Doppler. Isolated and cultured human umbilical vein endothelial cells from normal pregnancies were incubated with fetal plasma from three study groups. mRNA expression of intercellular cell adhesion molecule-1 (ICAM-1), vascular cell adhesion molecule-1 (VCAM-1) and platelet-endothelial cell adhesion molecule-1 (PECAM-1) were assessed by reverse transcription-polymerase chain reaction. To confirm the occurrence of this in vivo, we measured the levels of soluble fractions of sICAM-1, sVCAM-1 and sPECAM-1 in the fetal circulation in the fetal plasma used for endothelial cell incubation. The mRNA expression of ICAM-1 [median 1.1 (interquartile range 0.5-1.9) vs 0.7 (0.3-1.2), P < 0.05] and PECAM-1 [2.1 (1.2-3.0) vs 1.5 (0.7-2.1), P < 0.05] was significantly higher following incubation with fetal plasma from umbilical placental vascular disease compared with the normal group. There was no difference in the expression of VCAM-1 [1.2 (0.9-1.8) vs 1.1 (0.8-1.6), ns]. The group with maternal pre-eclampsia and normal umbilical artery Doppler did not differ from the normal group. In the umbilical placental vascular disease group, the results were similar in the presence or absence of pre-eclampsia. For soluble fractions of the adhesion molecules released into the fetal circulation, we found the levels (ng/mL) of sICAM- I [median 248.5 (interquartile range 197.3-315.7) vs 174.2 (144.5-212.9), P < 0.05] and sPECAM-1 [9.3 (6.2-11.1) vs 6.1 (5.4-7.7), P < 0.05] in fetal plasma to be significantly increased in the presence of umbilical placental vascular disease compared with the normal. Vascular disease in the fetal umbilical placental circulation is associated with an elevation in mRNA expression by endothelial cells of ICAM-1 and PECAM-1. Our study provides evidence for endothelial cell activation and dysfunction in umbilical placental vascular disease. We speculate that the plasma factor(s) affecting the vessels of the umbilical villous tree is locally released by the trophoblast. The occurrence of the maternal syndrome of pre-eclampsia appears to be independent of this.
Development of ITER non-activation phase operation scenarios
Kim, S. H.; Poli, F. M.; Koechl, F.; ...
2017-06-29
Non-activation phase operations in ITER in hydrogen (H) and helium (He) will be important for commissioning of tokamak systems, such as diagnostics, heating and current drive (HCD) systems, coils and plasma control systems, and for validation of techniques necessary for establishing operations in DT. The assessment of feasible HCD schemes at various toroidal fields (2.65–5.3 T) has revealed that the previously applied assumptions need to be refined for the ITER non-activation phase H/He operations. A study of the ranges of plasma density and profile shape using the JINTRAC suite of codes has indicated that the hydrogen pellet fuelling into Hemore » plasmas should be utilized taking the optimization of IC power absorption, neutral beam shine-through density limit and H-mode access into account. The EPED1 estimation of the edge pedestal parameters has been extended to various H operation conditions, and the combined EPED1 and SOLPS estimation has provided guidance for modelling the edge pedestal in H/He operations. The availability of ITER HCD schemes, ranges of achievable plasma density and profile shape, and estimation of the edge pedestal parameters for H/He plasmas have been integrated into various time-dependent tokamak discharge simulations. In this paper, various H/He scenarios at a wide range of plasma current (7.5–15 MA) and field (2.65–5.3 T) have been developed for the ITER non-activation phase operation, and the sensitivity of the developed scenarios to the used assumptions has been investigated to provide guidance for further development.« less
ECR Plasma Source for Heavy Ion Beam Charge Neutralization
NASA Astrophysics Data System (ADS)
Efthimion, P. C.; Gilson, E.; Grisham, L.; Davidson, R. C.; Yu, S.; Logan, B. G.
2002-11-01
Highly ionized plasmas are being considered as a medium for charge neutralizing heavy ion beams in order to focus beyond the space-charge limit. Calculations suggest that plasma at a density of 1 - 100 times the ion beam density and at a length ˜ 0.1-0.5 m would be suitable for achieving a high level of charge neutralization. An ECR source has been built at the Princeton Plasma Physics Laboratory (PPPL) to support a joint Neutralized Transport Experiment (NTX) at the Lawrence Berkeley National Laboratory (LBNL) to study ion beam neutralization with plasma. The ECR source operates at 13.6 MHz and with solenoid magnetic fields of 1-10 gauss. The goal is to operate the source at pressures ˜ 10-5 Torr at full ionization. The initial operation of the source has been at pressures of 10-4 - 10-1 Torr. Electron densities in the range of 10^8 - 10^11 cm-3 have been achieved. Low-pressure operation is important to reduce ion beam ionization. A cusp magnetic field has been installed to improve radial confinement and reduce the field strength on the beam axis. In addition, axial confinement is believed to be important to achieve lower-pressure operation. At moderate pressures (> 1 mTorr) the wave damping is collisional, and at low pressures (< 1 mTorr) there is a distinct electron cyclotron resonance. The source has recently been configured to operate with 2.45 GHz microwaves with similar results. At the present operating range the source can simulate the plasma produced by photo-ionization in the target chamber.
Development of ITER non-activation phase operation scenarios
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, S. H.; Poli, F. M.; Koechl, F.
Non-activation phase operations in ITER in hydrogen (H) and helium (He) will be important for commissioning of tokamak systems, such as diagnostics, heating and current drive (HCD) systems, coils and plasma control systems, and for validation of techniques necessary for establishing operations in DT. The assessment of feasible HCD schemes at various toroidal fields (2.65–5.3 T) has revealed that the previously applied assumptions need to be refined for the ITER non-activation phase H/He operations. A study of the ranges of plasma density and profile shape using the JINTRAC suite of codes has indicated that the hydrogen pellet fuelling into Hemore » plasmas should be utilized taking the optimization of IC power absorption, neutral beam shine-through density limit and H-mode access into account. The EPED1 estimation of the edge pedestal parameters has been extended to various H operation conditions, and the combined EPED1 and SOLPS estimation has provided guidance for modelling the edge pedestal in H/He operations. The availability of ITER HCD schemes, ranges of achievable plasma density and profile shape, and estimation of the edge pedestal parameters for H/He plasmas have been integrated into various time-dependent tokamak discharge simulations. In this paper, various H/He scenarios at a wide range of plasma current (7.5–15 MA) and field (2.65–5.3 T) have been developed for the ITER non-activation phase operation, and the sensitivity of the developed scenarios to the used assumptions has been investigated to provide guidance for further development.« less
Garofalo, Andrea M.; Burrell, Keith H.; Eldon, David; ...
2015-05-26
For the first time, DIII-D experiments have achieved stationary quiescent H-mode (QH-mode) operation for many energy confinement times at simultaneous ITER-relevant values of beta, confinement, and safety factor, in an ITER similar shape. QH-mode provides excellent energy confinement, even at very low plasma rotation, while operating without edge localized modes (ELMs) and with strong impurity transport via the benign edge harmonic oscillation (EHO). By tailoring the plasma shape to improve the edge stability, the QH-mode operating space has also been extended to densities exceeding 80% of the Greenwald limit, overcoming the long-standing low-density limit of QH-mode operation. In the theory,more » the density range over which the plasma encounters the kink-peeling boundary widens as the plasma cross-section shaping is increased, thus increasing the QH-mode density threshold. Here, the DIII-D results are in excellent agreement with these predictions, and nonlinear MHD analysis of reconstructed QH-mode equilibria shows unstable low n kink-peeling modes growing to a saturated level, consistent with the theoretical picture of the EHO. Furthermore, high density operation in the QH-mode regime has opened a path to a new, previously predicted region of parameter space, named “Super H-mode” because it is characterized by very high pedestals that can be more than a factor of two above the peeling-ballooning stability limit for similar ELMing H-mode discharges at the same density.« less
High-beta, steady-state hybrid scenario on DIII-D
Petty, C. C.; Kinsey, J. E.; Holcomb, C. T.; ...
2015-12-17
Here, the potential of the hybrid scenario (first developed as an advanced inductive scenario for high fluence) as a regime for high-beta, steady-state plasmas is demonstrated on the DIII-D tokamak. These experiments show that the beneficial characteristics of hybrids, namely safety factor ≥1 with low central magnetic shear, high stability limits and excellent confinement, are maintained when strong central current drive (electron cyclotron and neutral beam) is applied to increase the calculated non-inductive fraction to ≈100% (≈50% bootstrap current). The best discharges achieve normalized beta of 3.4, IPB98(y,2) confinement factor of 1.4, surface loop voltage of 0.01 V, and nearlymore » equal electron and ion temperatures at low collisionality. A zero-dimensional physics model shows that steady-state hybrid operation with Q fus ~ 5 is feasible in FDF and ITER. The advantage of the hybrid scenario as an Advanced Tokamak regime is that the external current drive can be deposited near the plasma axis where the efficiency is high; additionally, good alignment between the current drive and plasma current profiles is not necessary as the poloidal magnetic flux pumping self-organizes the current density profile in hybrids with an m/n=3/2 tearing mode.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Linke, J.; Bolt. H.; Breitbach, G.
1994-12-31
To assess the lifetime and the long term heat removal capabilities of plasma facing components in future thermonuclear fusion reactors such as ITER, neutron irradiation and subsequent high heat flux tests will be most essential. The effect of neutron damage will be simulated in material test reactors (such as the HFR-Petten) in a fission neutron environment. To investigate the heat loads during normal and off-normal operation scenarios a 60 kW electron beam test stand (Juelich Divertor Test Facility in Hot Cells, JUDITH) has been installed in a hot cell which can be operated by remote handling techniques. In this facilitymore » inertially cooled test coupons can be handled as well as small actively cooled divertor mock-ups. A special clamping mechanism for small test coupons (25 mm x 25 mm x 35 mm) with an integrated coolant channel within a copper or TZM heat sink has been developed and tested in an electron beam test bed. This method is an attractive alternative to costly large scale tests on complete divertor modules. The temperature and stress fields in individual CFC or beryllium tiles brazed to metallic heat sink (e.g. copper or TZM) can be investigated before and after neutron irradiation with moderate efforts.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Goulding, R. H.; Chen, G.; Meitner, S.
2009-11-26
Existing linear plasma materials interaction (PMI) facilities all use plasma sources with internal electrodes. An rf-based helicon source is of interest because high plasma densities can be generated with no internal electrodes, allowing true steady state operation with minimal impurity generation. Work has begun at Oak Ridge National Laboratory (ORNL) to develop a large (15 cm) diameter helicon source producing hydrogen plasmas with parameters suitable for use in a linear PMI device: n{sub e}{>=}10{sup 19} m{sup -3}, T{sub e} = 4-10 eV, particle flux {gamma}{sub p}>10{sup 23}m{sup -3} s{sup -1}, and magnetic field strength |B| up to 1 T inmore » the source region. The device, whose design is based on a previous hydrogen helicon source operated at ORNL[1], will operate at rf frequencies in the range 10-26 MHz, and power levels up to {approx}100 kW. Limitations in cooling will prevent operation for pulses longer than several seconds, but a major goal will be the measurement of power deposition on device structures so that a later steady state version can be designed. The device design, the diagnostics to be used, and results of rf modeling of the device will be discussed. These include calculations of plasma loading, resulting currents and voltages in antenna structures and the matching network, power deposition profiles, and the effect of high |B| operation on power absorption.« less
Predicting normal tissue radiosensitivity
NASA Astrophysics Data System (ADS)
Dickson, Jeanette
Two methods of predicting normal cell radiosensitivity were investigated in different patient groups. Plasma transforming growth factor beta one (TGFbeta1) levels were measured by ELISA, using a commercially available kit. Residual DNA double strand breaks were measured in normal epidermal fibroblasts following 150 Gy. After allowing 24 hours for repair, the DNA damage was assayed using pulsed field gel electrophoresis (PFGE). Pretreatment plasma TGFbeta1 levels were investigated retrospectively in patients with carcinoma of the cervix in relation to tumour control and late morbidity following radiotherapy. Plasma TGFbeta1 levels increased with increasing disease stage. They also correlated with two other known measures of tumour burden i.e. plasma levels of carcinoma antigen 125 (CA125) and tissue polypeptide antigen (TPA). Elevated pretreatment plasma TGFbeta1 levels predicted for a poor outcome both in terms of local control and overall survival. Plasma TGF?l levels did not predict for the development of radiotherapy morbidity of any grade. In conclusion pre-treatment plasma TGFbeta1 levels predict for tumour burden and tumour outcome in patients with carcinoma of the cervix. Changes in plasma TGFbeta1 levels measured prospectively may predict for radiation morbidity and should be investigated. A prospective study was undertaken in patients with carcinoma of the head and neck region. Changes in plasma TGFbeta1 levels between the start and the end of a course of radical radiotherapy were investigated in relation to the development of acute radiation toxicity. Patients were categorised according to the pattern of response of their TGFbeta1 levels over the course of their treatment. Those patients whose TGFbeta1 levels decreased, but did not normalise during radiotherapy were assigned to category 2. Category 2 predicted for a severe acute reaction, as measured using the LENT SOMA score, with a sensitivity of 33% and a specificity of 100%. The positive predictive value of was 100%. As part of the validation of the commercially available TGFbeta1 kit, samples were obtained from sixty-six normal volunteers with a wide age distribution. This large series demonstrated an unexpected age-related rise in TGFbeta1 levels that had not been previously demonstrated in the literature. In breast carcinoma patients, two assays were performed retrospectively. Both pre-treatment plasma TGFbeta1 levels and residual DNA double strand breaks (measured using PFGE) were correlated with clinical outcome. Outcome was in the form of a total LENT SOMA score and late radiation fibrosis score, as measured by clinical palpation. No relationship was demonstrated between either pretreatment TGFbeta1 levels or residual DNA double strand breaks and late radiotherapy outcome. This failed to validate a similar series of patients investigated in the same department using the same technique. This work has shown that measurement of residual DNA double strand breaks using PFGE is not sufficiently robust to be used clinically as a predictor of normal tissue radioresponse. In conclusion, changes in TGFbeta1 plasma levels occurring over time during a course of radical radiotherapy, hold promise for the development of a rapid test of intrinsic radiosensitivity.
Cold plasma processing technology makes advances
USDA-ARS?s Scientific Manuscript database
Cold plasma (AKA nonthermal plasma, cool plasma, gas plasma, etc.) is a rapidly maturing antimicrobial process being developed for applications in the food industry. A wide array of devices can be used to create cold plasma, but the defining characteristic is that they operate at or near room temper...
A 12 coil superconducting bumpy torus magnet facility for plasma research
NASA Technical Reports Server (NTRS)
Roth, J. R.; Holmes, A. D.; Keller, T. A.; Krawczonek, W. M.
1972-01-01
A summary is presented of the performance of the two-coil superconducting pilot rig which preceded the NASA Lewis bumpy torus. This pilot rig was operated for 550 experimental runs over a period of 7 years. The NASA Lewis bumpy torus facility consists of 12 superconducting coils, each with a 19 cm in diameter and capable of producing magnetic field strengths of 3.0 teslas on their axes. The magnets are equally spaced around a major circumference 1.52 m in diameter, and are mounted with the major axis of the torus vertical in a single vacuum tank 2.59 m in diameter. The design value of maximum magnetic field on the magnetic axis (3.0 teslas) was reached and exceeded. A maximum magnetic field of 3.23 teslas was held for a period of 60 minutes, and the coils did not go to normal. When the coils were charged to a maximum magnetic field of 3.35 teslas, the coil system was driven normal without damage to the facility.
Joint DIII-D/EAST Experiments Toward Steady State AT Demonstration
NASA Astrophysics Data System (ADS)
Garofalo, A. M.; Meneghini, O.; Staebler, G. M.; van Zeeland, M. A.; Gong, X.; Ding, S.; Qian, J.; Ren, Q.; Xu, G.; Grierson, B. A.; Solomon, W. M.; Holcomb, C. T.
2015-11-01
Joint DIII-D/EAST experiments on fully noninductive operation at high poloidal beta have demonstrated several attractive features of this regime for a steady-state fusion reactor. Very large bootstrap fraction (>80 %) is desirable because it reduces the demands on external noninductive current drive. High bootstrap fraction with an H-mode edge results in a broad current profile and internal transport barriers (ITBs) at large minor radius, leading to high normalized energy confinement and high MHD stability limits. The ITB radius expands with higher normalized beta, further improving both stability and confinement. Electron density ITB and large Shafranov shift lead to low AE activity in the plasma core and low anomalous fast ion losses. Both the ITB and the current profile show remarkable robustness against perturbations, without external control. Supported by US DOE under DE-FC02-04ER54698, DE-AC02-09CH11466 & DE-AC52-07NA27344 & by NMCFSP under contracts 2015GB102000 and 2015GB110001.
Hollow-Cathode Source Generates Plasma
NASA Technical Reports Server (NTRS)
Deininger, W. D.; Aston, G.; Pless, L. C.
1989-01-01
Device generates argon, krypton, or xenon plasma via thermionic emission and electrical discharge within hollow cathode and ejects plasma into surrounding vacuum. Goes from cold start up to full operation in less than 5 s after initial application of power. Exposed to moist air between operations without significant degradation of starting and running characteristics. Plasma generated by electrical discharge in cathode barrel sustained and aided by thermionic emission from emitter tube. Emitter tube does not depend on rare-earth oxides, making it vulnerable to contamination by exposure to atmosphere. Device modified for use as source of plasma in laboratory experiments or industrial processes.
Effect of normalized plasma frequency on electron phase-space orbits in a free-electron laser
NASA Astrophysics Data System (ADS)
Ji, Yu-Pin; Wang, Shi-Jian; Xu, Jing-Yue; Xu, Yong-Gen; Liu, Xiao-Xu; Lu, Hong; Huang, Xiao-Li; Zhang, Shi-Chang
2014-02-01
Irregular phase-space orbits of the electrons are harmful to the electron-beam transport quality and hence deteriorate the performance of a free-electron laser (FEL). In previous literature, it was demonstrated that the irregularity of the electron phase-space orbits could be caused in several ways, such as varying the wiggler amplitude and inducing sidebands. Based on a Hamiltonian model with a set of self-consistent differential equations, it is shown in this paper that the electron-beam normalized plasma frequency functions not only couple the electron motion with the FEL wave, which results in the evolution of the FEL wave field and a possible power saturation at a large beam current, but also cause the irregularity of the electron phase-space orbits when the normalized plasma frequency has a sufficiently large value, even if the initial energy of the electron is equal to the synchronous energy or the FEL wave does not reach power saturation.
Torigoe, Akira; Sato, Emiko; Mori, Takefumi; Ieiri, Norio; Takahashi, Chika; Ishida, Yoko; Hotta, Osamu; Ito, Sadayoshi
2016-10-01
Introduction Oxidative stress is one of the main mediators of progression of chronic kidney diseases (CKD). Nuclear factor E2-related factor 2 (Nrf2) is the transcription factor of antioxidant and detoxifying enzymes and related proteins which play an important role in cellular defense. Long-time hemodialysis (HD) therapy (8 hours) has been considered to be more beneficial compared to normal HD therapy (4 hours). We investigated oxidative response related to Nrf2 in peripheral blood mononuclear cells (PBMCs) of long-time HD and normal HD patients. Methods Eight adult long-time HD therapy patients (44.5 ± 3.0 years) and 10 normal HD therapy patients (68.1 ± 2.7 years) were enrolled. PBMCs were isolated and processed for expression of Nrf2 and its related genes by qRT-PCR. Plasma indoxyl sulfate, amino acids, and body constituents were measured. Findings Plasma indoxyl sulfate was significantly low after long-time HD therapy compare to that of normal HD therapy. Although, skeletal muscle mass, lean body mass, mineral and protein were significantly decreased 2 months in normal HD patients, those in long-time HD patients were significantly increased after 2 months. Almost of amino acids were significantly decreased after HD therapy in both HD therapies. Plasma amino acids were significantly low in long-time HD patients compared to normal HD patients. In PBMCs, the expression of Nrf2 was significantly decreased and hemooxygenase-1 expression was significantly increased in long-time HD compared to normal HD. Conclusion These observations indicate the beneficial effects of in long-time HD in improving oxidative stress in patients. © 2016 International Society for Hemodialysis.
Cecim, M; Kerr, J; Bartke, A
1995-05-01
Overexpression of growth hormone (GH) in transgenic mice is associated with various degrees of impairment of female reproductive functions. Transgenic PEPCK.bGH mice express high GH levels, and only around 20% of the females will carry gestation to Day 7. The objective of the present study was to investigate luteal function in PEPCK.bGH mice during early pregnancy, when CL are fully dependent on the pituitary. Plasma progesterone levels measured on Days 2 or 7 postcoitum (p.c.) were lower in transgenic than in normal females. In transgenic females with a previous history of infertility, daily injections of 1 mg progesterone starting on Day 2 p.c. significantly increased the proportion of animals pregnant on Day 7. When ovaries from transgenic mice were transplanted into ovariectomized normal littermates, the recipients exhibited normal vaginal cycles and responded to mating by vaginal cytology changes consistent with pseudopregnancy. In contrast, ovariectomized transgenic females bearing transplants of ovaries from normal mice had slightly prolonged estrous cycles and failed to become pseudopregnant after mating. Plasma progesterone levels on Days 2 and 7 p.c. in normal females with transgenic ovaries were not different from plasma progesterone levels measured in normal females into which normal ovaries had been transplanted. Twice-daily injections of 100 micrograms of prolactin (PRL) in saline or in polyvinylpyrrolidone starting on the evening of Day 2 p.c. were able to rescue luteal function. The proportion of PRL-injected transgenic animals that were pregnant on Day 7 was significantly higher than that of saline-injected transgenic controls and resembled the pregnancy rate of normal animals.(ABSTRACT TRUNCATED AT 250 WORDS)
Improvement of vertical stabilization on KSTAR
NASA Astrophysics Data System (ADS)
Mueller, D.; Bak, J. G.; Boyer, M. D.; Eideitis, N.; Hahn, S. H.; Humphreys, D. A.; Kim, H. S.; Jeon, Y. M.; Lanctot, M.; Walker, M. L.
2017-10-01
The successful control of strongly shaped plasmas on the Korea Superconducting Tokamak Advanced Research (KSTAR) device requires active feedback of fast motion of the plasma vertical position by the use of internal normal conducting coils (IVC). This has required new electronics to supply relative flux loop differences, for zp, and voltage loop differences, for dzp/dt, as well as a novel technique (Zfast) to use a high-pass filter, typically 1 Hz, on the error in the signal in the feedback loop. Use of Zfast avoids the potential contention encountered when the internal coil attempts to perform control of the plasma shape which should be controlled by the slower and more powerful superconducting coils. A common problem of this contention is saturation of the IVC and loss of fast vertical control. This is eliminated by proper use of the Zfast. A Ziegler-Nichols relay feedback system was used to fine tune the required feedback gains. The selection of the magnetic sensors, filter time constants, control gains and of the Zfast control strategy which allowed vertically stable operation at a plasma elongation, kappa. of up to 2.16 at li = 1.15 and Betap = 2.4 will be discussed which is beyond the design reference of KSTAR of kappa = 2.0 at li = 1.2 and Betap = 1.9. Work Supported by U.S.D.O.E. Contract No. DE-AC02-09CH11466 and DE-SC0010685 and the KSTAR project.
Characterisation of Plasma Filled Rod Pinch electron beam diode operation
NASA Astrophysics Data System (ADS)
MacDonald, James; Bland, Simon; Chittenden, Jeremy
2016-10-01
The plasma filled rod pinch diode (aka PFRP) offers a small radiographic spot size and a high brightness source. It operates in a very similar to plasma opening switches and dense plasma focus devices - with a plasma prefill, supplied via a number of simple coaxial plasma guns, being snowploughed along a thin rod cathode, before detaching at the end. The aim of this study is to model the PFRP and understand the factors that affect its performance, potentially improving future output. Given the dependence on the PFRP on the prefill, we are making detailed measurements of the density (1015-1018 cm-3), velocity, ionisation and temperature of the plasma emitted from a plasma gun/set of plasma guns. This will then be used to provide initial conditions to the Gorgon 3D MHD code, and the dynamics of the entire rod pinch process studied.
Magnetron cathodes in plasma electrode Pockels cells
Rhodes, M.A.
1995-04-25
Magnetron cathodes, which produce high current discharges, form greatly improved plasma electrodes on each side of an electro-optic crystal. The plasma electrode has a low pressure gas region on both sides of the crystal. When the gas is ionized, e.g., by a glow discharge in the low pressure gas, the plasma formed is a good conductor. The gas electrode acts as a highly uniform conducting electrode. Since the plasma is transparent to a high energy laser beam passing through the crystal, the plasma is transparent. A crystal exposed from two sides to such a plasma can be charged up uniformly to any desired voltage. A typical configuration utilizes helium at 50 millitorr operating pressure and 2 kA discharge current. The magnetron cathode produces a more uniform plasma and allows a reduced operating pressure which leads to lower plasma resistivity and a more uniform charge on the crystal. 5 figs.
Magnetron cathodes in plasma electrode pockels cells
Rhodes, Mark A.
1995-01-01
Magnetron cathodes, which produce high current discharges, form greatly improved plasma electrodes on each side of an electro-optic crystal. The plasma electrode has a low pressure gas region on both sides of the crystal. When the gas is ionized, e.g., by a glow discharge in the low pressure gas, the plasma formed is a good conductor. The gas electrode acts as a highly uniform conducting electrode. Since the plasma is transparent to a high energy laser beam passing through the crystal, the plasma is transparent. A crystal exposed from two sides to such a plasma can be charged up uniformly to any desired voltage. A typical configuration utilizes helium at 50 millitorr operating. pressure and 2 kA discharge current. The magnetron cathode produces a more uniform plasma and allows a reduced operating pressure which leads to lower plasma resistivity and a more uniform charge on the crystal.
Fast-ion transport in qmin>2, high- β steady-state scenarios on DIII-D
Holcomb, C. T.; Heidbrink, W. W.; Ferron, J. R.; ...
2015-05-22
The results from experiments on DIII-D [J. L. Luxon, Fusion Sci. Technol. 48, 828 (2005)] aimed at developing high β steady-state operating scenarios with high-qminqmin confirm that fast-ion transport is a critical issue for advanced tokamak development using neutral beam injection current drive. In DIII-D, greater than 11 MW of neutral beam heating power is applied with the intent of maximizing β N and the noninductive current drive. However, in scenarios with q min>2 that target the typical range of q 95= 5–7 used in next-step steady-state reactor models, Alfvén eigenmodes cause greater fast-ion transport than classical models predict. Thismore » enhanced transport reduces the absorbed neutral beam heating power and current drive and limits the achievable β N. Conversely similar plasmas except with q min just above 1 have approximately classical fast-ion transport. Experiments that take q min>3 plasmas to higher β P with q 95= 11–12 for testing long pulse operation exhibit regimes of better than expected thermal confinement. Compared to the standard high-q min scenario, the high β P cases have shorter slowing-down time and lower ∇β fast, and this reduces the drive for Alfvénic modes, yielding nearly classical fast-ion transport, high values of normalized confinement, β N, and noninductive current fraction. These results suggest DIII-D might obtain better performance in lower-q 95, high-q min plasmas using broader neutral beam heating profiles and increased direct electron heating power to lower the drive for Alfvén eigenmodes.« less
Fast-ion transport in q{sub min}>2, high-β steady-state scenarios on DIII-D
DOE Office of Scientific and Technical Information (OSTI.GOV)
Holcomb, C. T.; Heidbrink, W. W.; Collins, C.
2015-05-15
Results from experiments on DIII-D [J. L. Luxon, Fusion Sci. Technol. 48, 828 (2005)] aimed at developing high β steady-state operating scenarios with high-q{sub min} confirm that fast-ion transport is a critical issue for advanced tokamak development using neutral beam injection current drive. In DIII-D, greater than 11 MW of neutral beam heating power is applied with the intent of maximizing β{sub N} and the noninductive current drive. However, in scenarios with q{sub min}>2 that target the typical range of q{sub 95}= 5–7 used in next-step steady-state reactor models, Alfvén eigenmodes cause greater fast-ion transport than classical models predict. Thismore » enhanced transport reduces the absorbed neutral beam heating power and current drive and limits the achievable β{sub N}. In contrast, similar plasmas except with q{sub min} just above 1 have approximately classical fast-ion transport. Experiments that take q{sub min}>3 plasmas to higher β{sub P} with q{sub 95}= 11–12 for testing long pulse operation exhibit regimes of better than expected thermal confinement. Compared to the standard high-q{sub min} scenario, the high β{sub P} cases have shorter slowing-down time and lower ∇β{sub fast}, and this reduces the drive for Alfvénic modes, yielding nearly classical fast-ion transport, high values of normalized confinement, β{sub N}, and noninductive current fraction. These results suggest DIII-D might obtain better performance in lower-q{sub 95}, high-q{sub min} plasmas using broader neutral beam heating profiles and increased direct electron heating power to lower the drive for Alfvén eigenmodes.« less
21 CFR 866.5250 - Complement C2 inhibitor (inactivator) immunological test system.
Code of Federal Regulations, 2010 CFR
2010-04-01
... the reagents used to measure by immunochemical techniques the complement C1 inhibitor (a plasma protein) in serum. Complement C1 inhibitor occurs normally in plasma and blocks the action of the C1...
21 CFR 866.5250 - Complement C2 inhibitor (inactivator) immunological test system.
Code of Federal Regulations, 2012 CFR
2012-04-01
... the reagents used to measure by immunochemical techniques the complement C1 inhibitor (a plasma protein) in serum. Complement C1 inhibitor occurs normally in plasma and blocks the action of the C1...
21 CFR 866.5250 - Complement C2 inhibitor (inactivator) immunological test system.
Code of Federal Regulations, 2011 CFR
2011-04-01
... the reagents used to measure by immunochemical techniques the complement C1 inhibitor (a plasma protein) in serum. Complement C1 inhibitor occurs normally in plasma and blocks the action of the C1...
21 CFR 866.5250 - Complement C 2 inhibitor (inactivator) immunological test system.
Code of Federal Regulations, 2013 CFR
2013-04-01
... the reagents used to measure by immunochemical techniques the complement C1 inhibitor (a plasma protein) in serum. Complement C1 inhibitor occurs normally in plasma and blocks the action of the C1...
21 CFR 866.5250 - Complement C 2 inhibitor (inactivator) immunological test system.
Code of Federal Regulations, 2014 CFR
2014-04-01
... the reagents used to measure by immunochemical techniques the complement C1 inhibitor (a plasma protein) in serum. Complement C1 inhibitor occurs normally in plasma and blocks the action of the C1...
Cold Atmosphere Plasma in Cancer Therapy
NASA Astrophysics Data System (ADS)
Keidar, Michael
2012-10-01
Plasma is an ionized gas that is typically generated in high-temperature laboratory conditions. Recent progress in atmospheric plasmas led to the creation of cold plasmas with ion temperature close to room temperature. Areas of potential application of cold atmospheric plasmas (CAP) include dentistry, drug delivery, dermatology, cosmetics, wound healing, cellular modifications, and cancer treatment. Various diagnostic tools have been developed for characterization of CAP including intensified charge-coupled device cameras, optical emission spectroscopy and electrical measurements of the discharge propertied. Recently a new method for temporally resolved measurements of absolute values of plasma density in the plasma column of small-size atmospheric plasma jet utilizing Rayleigh microwave scattering was proposed [1,2]. In this talk we overview state of the art of CAP diagnostics and understanding of the mechanism of plasma action of biological objects. The efficacy of cold plasma in a pre-clinical model of various cancer types (long, bladder, and skin) was recently demonstrated [3]. Both in-vitro and in-vivo studies revealed that cold plasmas selectively kill cancer cells. We showed that: (a) cold plasma application selectively eradicates cancer cells in vitro without damaging normal cells. For instance a strong selective effect was observed; the resulting 60--70% of lung cancer cells were detached from the plate in the zone treated with plasma, whereas no detachment was observed in the treated zone for the normal lung cells under the same treatment conditions. (b) Significantly reduced tumor size in vivo. Cold plasma treatment led to tumor ablation with neighbouring tumors unaffected. These experiments were performed on more than 10 mice with the same outcome. We found that tumors of about 5mm in diameter were ablated after 2 min of single time plasma treatment. The two best known cold plasma effects, plasma-induced apoptosis and the decrease of cell migration velocity can have important implications in cancer treatment by localizing the affected area of the tissue and by decreasing metastasic development. In addition, cold plasma treatment has affected the cell cycle of cancer cells. In particular, cold plasma induces a 2-fold increase in cells at the G2/M-checkpoint in both papilloma and carcinoma cells at about 24 hours after treatment, while normal epithelial cells (WTK) did not show significant differences. It was shown that reactive oxygen species metabolism and oxidative stress responsive genes are deregulated. We investigated the production of reactive oxygen species (ROS) with cold plasma treatment as a potential mechanism for the tumor ablation observed. [4pt] [1] Shashurin A., Shneider M.N., Dogariu A., Miles R.B. and Keidar M. Appl. Phys. Lett. (2010) 96, 171502.[0pt] [2] Shashurin A., Shneider M.N., Keidar M. Plasma Sources Sci. Technol. 21 (2012) 034006.[0pt] [3]. M. Keidar, R. Walk, A. Shashurin, P. Srinivasan, A. Sandler, S. Dasgupta , R. Ravi, R. Guerrero-Preston, B. Trink, British Journal of Cancer, 105, 1295-1301, 2011
Two-stage plasma gun based on a gas discharge with a self-heating hollow emitter.
Vizir, A V; Tyunkov, A V; Shandrikov, M V; Oks, E M
2010-02-01
The paper presents the results of tests of a new compact two-stage bulk gas plasma gun. The plasma gun is based on a nonself-sustained gas discharge with an electron emitter based on a discharge with a self-heating hollow cathode. The operating characteristics of the plasma gun are investigated. The discharge system makes it possible to produce uniform and stable gas plasma in the dc mode with a plasma density up to 3x10(9) cm(-3) at an operating gas pressure in the vacuum chamber of less than 2x10(-2) Pa. The device features high power efficiency, design simplicity, and compactness.
King, M. K.
1960-01-01
The endogenous pyrogen in the serum or plasma of rabbits 2 hours after the intravenous injection of typhoid vaccine had a marked effect on the circulating leucocytes of normal rabbits. Immediately following intravenous injection there was a brief, but marked, granulocytopenia which was quickly followed by a granulocytosis. Under the same circumstances pooled heterologous serum or plasma from normal rabbits produced no fever or significant change in the level of circulating leucocytes. The cell-free fluid of sterile peritoneal exudates produced a marked leucocytosis without a preceding leucopenia when injected intravenously into normal rabbits. When comparably pyrogenic doses of typhoid vaccine were injected in the same manner no significant change in the level of circulating leucocytes occurred. The relevance of these findings to the pathogenesis of fever is discussed. PMID:13756095
KING, M K
1960-11-01
The endogenous pyrogen in the serum or plasma of rabbits 2 hours after the intravenous injection of typhoid vaccine had a marked effect on the circulating leucocytes of normal rabbits. Immediately following intravenous injection there was a brief, but marked, granulocytopenia which was quickly followed by a granulocytosis. Under the same circumstances pooled heterologous serum or plasma from normal rabbits produced no fever or significant change in the level of circulating leucocytes. The cell-free fluid of sterile peritoneal exudates produced a marked leucocytosis without a preceding leucopenia when injected intravenously into normal rabbits. When comparably pyrogenic doses of typhoid vaccine were injected in the same manner no significant change in the level of circulating leucocytes occurred. The relevance of these findings to the pathogenesis of fever is discussed.
A plasma microRNA signature as a biomarker for acquired aplastic anemia.
Hosokawa, Kohei; Kajigaya, Sachiko; Feng, Xingmin; Desierto, Marie J; Fernandez Ibanez, Maria Del Pilar; Rios, Olga; Weinstein, Barbara; Scheinberg, Phillip; Townsley, Danielle M; Young, Neal S
2017-01-01
Aplastic anemia is an acquired bone marrow failure characterized by marrow hypoplasia, a paucity of hematopoietic stem and progenitor cells, and pancytopenia of the peripheral blood, due to immune attack on the bone marrow. In aplastic anemia, a major challenge is to develop immune biomarkers to monitor the disease. We measured circulating microRNAs in plasma samples of aplastic anemia patients in order to identify disease-specific microRNAs. A total of 179 microRNAs were analyzed in 35 plasma samples from 13 aplastic anemia patients, 11 myelodysplastic syndrome patients, and 11 healthy controls using the Serum/Plasma Focus microRNA Polymerase Chain Reaction Panel. Subsequently, 19 microRNAs from the discovery set were investigated in the 108 plasma samples from 41 aplastic anemia patients, 24 myelodysplastic syndrome patients, and 43 healthy controls for validation, confirming that 3 microRNAs could be validated as dysregulated (>1.5-fold change) in aplastic anemia, compared to healthy controls. MiR-150-5p (induction of T-cell differentiation) and miR-146b-5p (involvement in the feedback regulation of innate immune response) were elevated in aplastic anemia plasma, whereas miR-1 was decreased in aplastic anemia. By receiver operating characteristic curve analysis, we developed a logistic model with these 3 microRNAs that enabled us to predict the probability of a diagnosis of aplastic anemia with an area under the curve of 0.86. Dysregulated expression levels of the microRNAs became normal after immunosuppressive therapy at 6 months. Specifically, miR-150-5p expression was significantly reduced after successful immunosuppressive therapy, but did not change in non-responders. We propose 3 novel plasma biomarkers in aplastic anemia, in which miR-150-5p, miR-146b-5p, and miR-1 can serve for diagnosis and miR-150-5p for disease monitoring. Clinicaltrials.gov identifiers:00260689, 00217594, 00961064. Copyright© Ferrata Storti Foundation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Phelps, M.E.; Mazziotta, J.C.; Hawkins, R.A.
1981-01-01
Glycogen storage disease type I (GSD-I) is characterized by a functional deficit in glucose-6-phosphatase that normally hydrolyzes glucose-6-PO/sub 4/ to glucose. This enzyme is primarily found in liver, kidney, and muscle but it is also present in brain, where it appears to participate in the regulation of cerebral tissue glucose. Since most neurological symptoms in GSD-I patients involve systemic hypoglycemia, previous reports have not examined possible deficiencies in phosphatase activity in the brain. Positron computed tomography, F-18-labeled 2-fluorodeoxyglucose (FDG) and a tracer kinetic model for FDG were used to measure the cortical plasma/tissue forward and reverse transport, phosphorylation and dephosphorylationmore » rate constants, tissue/plasma concentration gradient, tissue concentration turnover rate for this competitive analog of glucose, and the cortical metabolic rates for glucose. Studies were carried out in age-matched normals (N = 13) and a single GSD-I patient. The dephosphorylation rate constant in the GSD-I patient was about one tenth the normal value indicating a low level of cerebral phosphatase activity. The other measured parameters were within normal limits except for the rate of glucose phosphorylation which reflected a cortical glucose metabolic rate one half the normal value. Since glucose transport and tissue glucose concentration was normal, the reduced cortical glucose metabolism probably results from the use of alternative substrates (..beta..-hydroxybutyrate and acetoacetate) which are consistently elevated in the plasma of GSD-I patients.« less
Praveen, Edavan P; Kulshreshtha, Bindu; Khurana, Madan L; Sahoo, Jayaprakash; Gupta, Nandita; Kumar, Guresh; Ammini, Ariachery; Knadgawat, Rajech
2011-01-01
Offspring of type 2 diabetics have an increased risk of dyslipidemia, glucose intolerance and obesity. The aim of this study was to assess the lipid levels in the offspring of diabetics with normal glucose tolerance and normal body weight. Normal weight offspring of patients with type 2 diabetes mellitus (DM) who had normal glucose tolerance, and healthy gender matched controls of comparable age without a family history of diabetes mellitus, were the subjects of this study. Lipid profiles were determined in cases and controls. The study included 114 subjects (64 males and 50 females) in each group, aged (mean ± SD) 24.0 ± 7.9 in cases and 24.1 ± 8.0 years in controls. The body mass index (BMI) was 20.8 ± 3.0 and 20.2 ± 3.1 kg/m2 in cases and controls, respectively. Serum total cholesterol, triglycerides, plasma glucose, fasting insulin, C-peptide and proinsulin levels were comparable in cases and controls. Serum high density lipoprotein (HDL) cholesterol was lower (p <0.001), whilst the serum triglyceride/HDL ratio, low density lipoprotein (LDL) cholesterol and area under the curve for insulin and proinsulin during an oral glucose tolerance test were higher in cases compared to controls. HDL cholesterol showed no significant correlation with plasma glucose, insulin or proinsulin. Plasma HDL cholesterol is low among normal weight, normoglycemic offspring of subjects with type 2 diabetes mellitus. The implications of this finding are not apparent.
Enhanced target normal sheath acceleration based on the laser relativistic self-focusing
NASA Astrophysics Data System (ADS)
Zou, D. B.; Zhuo, H. B.; Yang, X. H.; Shao, F. Q.; Ma, Y. Y.; Yu, T. P.; Wu, H. C.; Yin, Y.; Ge, Z. Y.; Li, X. H.
2014-06-01
The enhanced target normal sheath acceleration of ions in laser target interaction via the laser relativistic self-focusing effect is investigated by theoretical analysis and particle-in-cell simulations. The temperature of the hot electrons in the underdense plasma is greatly increased due to the occurrence of resonant absorption, while the electron-betatron-oscillation frequency is close to its witnessed laser frequency [Pukhov et al., Phys. Plasma 6, 2847 (1999)]. While these hot electrons penetrate through the backside solid target, a stronger sheath electric field at the rear surface of the target is induced, which can accelerate the protons to a higher energy. It is also shown that the optimum length of the underdense plasma is approximately equal to the self-focusing distance.
Bernstein modes in a non-neutral plasma column
NASA Astrophysics Data System (ADS)
Walsh, Daniel; Dubin, Daniel H. E.
2018-05-01
This paper presents theory and numerical calculations of electrostatic Bernstein modes in an inhomogeneous cylindrical plasma column. These modes rely on finite Larmor radius effects to propagate radially across the column until they are reflected when their frequency matches the upper hybrid frequency. This reflection sets up an internal normal mode on the column and also mode-couples to the electrostatic surface cyclotron wave (which allows the normal mode to be excited and observed using external electrodes). Numerical results predicting the mode spectra, using a novel linear Vlasov code on a cylindrical grid, are presented and compared to an analytical Wentzel Kramers Brillouin (WKB) theory. A previous version of the theory [D. H. E. Dubin, Phys. Plasmas 20(4), 042120 (2013)] expanded the plasma response in powers of 1/B, approximating the local upper hybrid frequency, and consequently, its frequency predictions are spuriously shifted with respect to the numerical results presented here. A new version of the WKB theory avoids this approximation using the exact cold fluid plasma response and does a better job of reproducing the numerical frequency spectrum. The effect of multiple ion species on the mode spectrum is also considered, to make contact with experiments that observe cyclotron modes in a multi-species pure ion plasma [M. Affolter et al., Phys. Plasmas 22(5), 055701 (2015)].
Stellarator Coil Design and Plasma Sensitivity
DOE Office of Scientific and Technical Information (OSTI.GOV)
Long-Poe Ku and Allen H. Boozer
2010-11-03
The rich information contained in the plasma response to external magnetic perturbations can be used to help design stellarator coils more effectively. We demonstrate the feasibility by first devel- oping a simple, direct method to study perturbations in stellarators that do not break stellarator symmetry and periodicity. The method applies a small perturbation to the plasma boundary and evaluates the resulting perturbed free-boundary equilibrium to build up a sensitivity matrix for the important physics attributes of the underlying configuration. Using this sensitivity information, design methods for better stellarator coils are then developed. The procedure and a proof-of-principle application are givenmore » that (1) determine the spatial distributions of external normal magnetic field at the location of the unperturbed plasma boundary to which the plasma properties are most sen- sitive, (2) determine the distributions of external normal magnetic field that can be produced most efficiently by distant coils, (3) choose the ratios of the magnitudes of the the efficiently produced magnetic distributions so the sensitive plasma properties can be controlled. Using these methods, sets of modular coils are found for the National Compact Stellarator Experiment (NCSX) that are either smoother or can be located much farther from the plasma boundary than those of the present design.« less
Sekizawa, Akihiko; Ventura, Walter; Koide, Keiko; Hori, Kyouko; Okai, Takashi; Masashi, Yoshida; Furuya, Kenichi; Mizumoto, Yoshifumi
2014-01-01
We compared the levels of cell-free human placental lactogen (hPL) messenger RNA (mRNA) in maternal plasma at 28 to 32 weeks of gestation between women with diagnosis of placenta previa or invasive placenta and women with an uneventful pregnancy. Sensitivity and specificity of hPL mRNA for the prediction of invasive placenta were further explored. Plasma hPL mRNA were quantified by real-time reverse-transcriptase polymerase chain reaction in women with placenta previa (n = 13), invasive placenta (n = 5), and normal pregnancies (n = 92). Median (range) hPL mRNA was significantly higher in women with placenta previa, 782 (10-2301) copies/mL of plasma, and in those with invasive placenta, 615 (522-2102) copies/mL of plasma, when compared to normal pregnancies, 90 (4-4407) copies/mL of plasma, P < .01 and P < .05, respectively. We found a sensitivity of 100% and a specificity of 61.5% for the prediction of invasive placenta among women with placenta previa. In conclusion, expression of hPL mRNA is increased in plasma of women with placenta previa and invasive placenta at 28 to 32 weeks of gestation. PMID:23744883
Kawashima, Akihiro; Sekizawa, Akihiko; Ventura, Walter; Koide, Keiko; Hori, Kyouko; Okai, Takashi; Masashi, Yoshida; Furuya, Kenichi; Mizumoto, Yoshifumi
2014-02-01
We compared the levels of cell-free human placental lactogen (hPL) messenger RNA (mRNA) in maternal plasma at 28 to 32 weeks of gestation between women with diagnosis of placenta previa or invasive placenta and women with an uneventful pregnancy. Sensitivity and specificity of hPL mRNA for the prediction of invasive placenta were further explored. Plasma hPL mRNA were quantified by real-time reverse-transcriptase polymerase chain reaction in women with placenta previa (n = 13), invasive placenta (n = 5), and normal pregnancies (n = 92). Median (range) hPL mRNA was significantly higher in women with placenta previa, 782 (10-2301) copies/mL of plasma, and in those with invasive placenta, 615 (522-2102) copies/mL of plasma, when compared to normal pregnancies, 90 (4-4407) copies/mL of plasma, P < .01 and P < .05, respectively. We found a sensitivity of 100% and a specificity of 61.5% for the prediction of invasive placenta among women with placenta previa. In conclusion, expression of hPL mRNA is increased in plasma of women with placenta previa and invasive placenta at 28 to 32 weeks of gestation.
de Miguel, Dunia; Burgaleta, Carmen; Reyes, Eduardo; Pascual, Teresa
2003-07-01
We evaluated a new portable monitor (AvoSure PT PRO, Menarini Diagnostics, Firenze, Italy) developed to test the prothrombin time in capillary blood and plasma by comparing it with the standard laboratory determination. We studied 62 patients receiving acenocoumarol therapy. The international normalized ratio (INR) in capillary blood was analyzed by 2 methods: AvoSure PT PRO and Thrombotrack Nycomed Analyzer (Axis-Shield, Dundee, Scotland). Parallel studies were performed in plasma samples by a reference method using the Behring Coagulation Timer (Behring Diagnostics, Marburg, Germany). Plasma samples also were tested with the AvoSure PT PRO. Correlation was good for INR values for capillary blood and plasma samples by AvoSure PT PRO and our reference method (R2 = 0.8596) and for capillary blood samples tested by the AvoSure PT PRO and Thrombotrack Nycomed Analyzer (R2 = 0.8875). The correlation for INR in capillary blood and plasma samples by AvoSure PT PRO was 0.6939 (P < .0004). Capillary blood determinations are rapid and effective for monitoring oral anticoagulation therapy and have a high correlation to plasma determinations. AvoSure PT PRO is accurate for controlling INR in plasma and capillary blood samples, may be used in outpatient clinics, and has advantages over previous portable monitors.
[Can a selenium deficiency affect the pathogenesis of cholestasis in pregnancy?].
Ribalta, J; Reyes, H; Hernández, I; Fuentes, O; Báez, M; González, M; Palma, J
1995-03-01
In search of an environmental factor which modulates the expressivity of cholestasis of pregnancy and explains the seasonal and annual variations observed in Finland and Chile, the authors measured selenium (Se) concentration in the plasma and erythrocytes by atomic absorption spectrophotometry and the activity of the glutation peroxidase enzyme dependent on Se (GSH-Px) by a spectrophotometric method in 10 patients with cholestasis of pregnancy, 22 normal pregnant women, 43 non pregnant women and in 15 men, all of whom had normal weight/height, and similar ages, ethnic and geographic origin. Blood samples were obtained weekly from the pregnant women during the third trimester and 24-72 hours postpartum. In non pregnant women and in men plasma Se was 0.83 +/- 0.02 mumol/l (range 0.6-1.2) and the GSH-Px activity was 306 +/- 5 U/L (range 203-459). Both parameters were correlated and were similar to those of other populations whose ingestion of Se is low (Finland, New Zealand, and certain regions of China). In normal pregnant women studied between weeks 20 and 32, the plasma Se and GSH-Px activity were lower than in non pregnant women (0.71 +/- 0.02 mumol/l and 260 +/- 5 U/l, respectively) with both progressively decreasing at the end of pregnancy and rapidly recovering post partum. The erythrocytic GSH-Px activity was similar in normal pregnant women than in non pregnant women (27.7 +/- 0.8 versus 28.1 +/- 0.6 U/g Hb). In patients with cholestasis of pregnancy, plasma and erythrocytic Se and GSH-Px activity were lower than in normal pregnant women (p < 0.05 in similar stages of pregnancy).(ABSTRACT TRUNCATED AT 250 WORDS)
Takahashi, Kazunori; Komuro, Atsushi; Ando, Akira
2015-02-01
Momentum, i.e., force, exerted from a small helicon plasma thruster to a target plate is measured simultaneously with a direct thrust measurement using a thrust balance. The calibration coefficient relating a target displacement to a steady-state force is obtained by supplying a dc to a calibration coil mounted on the target, where a force acting to a small permanent magnet located near the coil is directly measured by using a load cell. As the force exerted by the plasma flow to the target plate is in good agreement with the directly measured thrust, the validity of the target technique is demonstrated under the present operating conditions, where the thruster is operated in steady-state. Furthermore, a calibration coefficient relating a swing amplitude of the target to an impulse bit is also obtained by pulsing the calibration coil current. The force exerted by the pulsed plasma, which is estimated from the measured impulse bit and the pulse width, is also in good agreement with that obtained for the steady-state operation; hence, the thrust assessment of the helicon plasma thruster by the target is validated for both the steady-state and pulsed operations.
Progress and prospect of true steady state operation with RF
NASA Astrophysics Data System (ADS)
Jacquinot, Jean
2017-10-01
Operation of fusion confinement experiments in full steady state is a major challenge for the development towards fusion energy. Critical to achieving this goal is the availability of actively cooled plasma facing components and auxiliary systems withstanding the very harsh plasma environment. Equally challenging are physics issues related to achieving plasma conditions and current drive efficiency required by reactor plasmas. RF heating and current drive systems have been key instruments for obtaining the progress made until today towards steady state. They hold all the records of long pulse plasma operation both in tokamaks and in stellarators. Nevertheless much progress remains to be made in particular for integrating all the requirements necessary for maintaining in steady state the density and plasma pressure conditions of a reactor. This is an important stated aim of ITER and of devices equipped with superconducting magnets. After considering the present state of the art, this review will address the key issues which remain to be solved both in physics and technology for reaching this goal. They constitute very active subjects of research which will require much dedicated experimentation in the new generation of superconducting devices which are now in operation or becoming close to it.
Method and apparatus for monitoring plasma processing operations
Smith, Jr., Michael Lane; Stevenson, Joel O'Don; Ward, Pamela Peardon Denise
2001-01-01
The invention generally relates to various aspects of a plasma process, and more specifically the monitoring of such plasma processes. One aspect relates in at least some manner to calibrating or initializing a plasma monitoring assembly. This type of calibration may be used to address wavelength shifts, intensity shifts, or both associated with optical emissions data obtained on a plasma process. A calibration light may be directed at a window through which optical emissions data is being obtained to determine the effect, if any, that the inner surface of the window is having on the optical emissions data being obtained therethrough, the operation of the optical emissions data gathering device, or both. Another aspect relates in at least some manner to various types of evaluations which may be undertaken of a plasma process which was run, and more typically one which is currently being run, within the processing chamber. Plasma health evaluations and process identification through optical emissions analysis are included in this aspect. Yet another aspect associated with the present invention relates in at least some manner to the endpoint of a plasma process (e.g., plasma recipe, plasma clean, conditioning wafer operation) or discrete/discernible portion thereof (e.g., a plasma step of a multiple step plasma recipe). A final aspect associated with the present invention relates to how one or more of the above-noted aspects may be implemented into a semiconductor fabrication facility, such as the distribution of wafers to a wafer production system.
Method and apparatus for monitoring plasma processing operations
Smith, Jr., Michael Lane; Stevenson, Joel O'Don; Ward, Pamela Peardon Denise
2001-01-01
The invention generally relates to various aspects of a plasma process, and more specifically the monitoring of such plasma processes. One aspect relates in at least some manner to calibrating or initializing a plasma monitoring assembly. This type of calibration may be used to address wavelength shifts, intensity shifts, or both associated with optical emissions data obtained on a plasma process. A calibration light may be directed at a window through which optical emissions data is being obtained to determine the effect, if any, that the inner surface of the window is having on the optical emissions data being obtained therethrough, the operation of the optical emissions data gathering device, or both. Another aspect relates in at least some manner to various types of evaluations which may be undertaken of a plasma process which was run, and more typically one which is currently being run, within the processing chamber. Plasma health evaluations and process identification through optical emissions analysis are included in this aspect. Yet another aspect associated with the present invention relates in at least some manner to the endpoint of a plasma process (e.g., plasma recipe, plasma clean, conditioning wafer operation) or discrete/discemible portion thereof (e.g., a plasma step of a multiple step plasma recipe). A final aspect associated with the present invention relates to how one or more of the above-noted aspects may be implemented into a semiconductor fabrication facility, such as the distribution of wafers to a wafer production system.
Method and apparatus for monitoring plasma processing operations
Smith, Jr., Michael Lane; Stevenson, Joel O'Don; Ward, Pamela Peardon Denise
2000-01-01
The invention generally relates to various aspects of a plasma process, and more specifically the monitoring of such plasma processes. One aspect relates in at least some manner to calibrating or initializing a plasma monitoring assembly. This type of calibration may be used to address wavelength shifts, intensity shifts, or both associated with optical emissions data obtained on a plasma process. A calibration light may be directed at a window through which optical emissions data is being obtained to determine the effect, if any, that the inner surface of the window is having on the optical emissions data being obtained therethrough, the operation of the optical emissions data gathering device, or both. Another aspect relates in at least some manner to various types of evaluations which may be undertaken of a plasma process which was run, and more typically one which is currently being run, within the processing chamber. Plasma health evaluations and process identification through optical emissions analysis are included in this aspect. Yet another aspect associated with the present invention relates in at least some manner to the endpoint of a plasma process (e.g., plasma recipe, plasma clean, conditioning wafer operation) or discrete/discernible portion thereof (e.g., a plasma step of a multiple step plasma recipe). A final aspect associated with the present invention relates to how one or more of the above-noted aspects may be implemented into a semiconductor fabrication facility, such as the distribution of wafers to a wafer production system.
Method and apparatus for monitoring plasma processing operations
Smith, Jr., Michael Lane; Stevenson, Joel O'Don; Ward, Pamela Peardon Denise
2002-07-16
The invention generally relates to various aspects of a plasma process, and more specifically the monitoring of such plasma processes. One aspect relates in at least some manner to calibrating or initializing a plasma monitoring assembly. This type of calibration may be used to address wavelength shifts, intensity shifts, or both associated with optical emissions data obtained on a plasma process. A calibration light may be directed at a window through which optical emissions data is being obtained to determine the effect, if any, that the inner surface of the window is having on the optical emissions data being obtained therethrough, the operation of the optical emissions data gathering device, or both. Another aspect relates in at least some manner to various types of evaluations which may be undertaken of a plasma process which was run, and more typically one which is currently being run, within the processing chamber. Plasma health evaluations and process identification through optical emissions analysis are included in this aspect. Yet another aspect associated with the present invention relates in at least some manner to the endpoint of a plasma process (e.g., plasma recipe, plasma clean, conditioning wafer operation) or discrete/discernible portion thereof (e.g., a plasma step of a multiple step plasma recipe). A final aspect associated with the present invention relates to how one or more of the above-noted aspects may be implemented into a semiconductor fabrication facility, such as the distribution of wafers to a wafer production system.
Atchison, Douglas K.; Harding, Pamela
2013-01-01
1, 25-Dihydroxycholechalciferol (calcitriol) and 19-nor-1, 25-dihydroxyvitamin D2 (paricalcitol) are vitamin D receptor (VDR) agonists. Previous data suggest VDR agonists may actually increase renin-angiotensin activity, and this has always been assumed to be mediated by hypercalcemia. We hypothesized that calcitriol and paricalcitol would increase plasma renin activity (PRA) independently of plasma Ca2+ via hypercalciuria-mediated polyuria, hypovolemia, and subsequent increased β-adrenergic sympathetic activity. We found that both calcitriol and paricalcitol increased PRA threefold (P < 0.01). Calcitriol caused hypercalcemia, but paricalcitol did not. Both calcitriol and paricalcitol caused hypercalciuria (9- and 7-fold vs. control, P < 0.01) and polyuria (increasing 2.6- and 2.2-fold vs. control, P < 0.01). Paricalcitol increased renal calcium-sensing receptor (CaSR) expression, suggesting a potential cause of paricalcitol-mediated hypercalciuria and polyuria. Volume replacement completely normalized calcitriol-stimulated PRA and lowered plasma epinephrine by 43% (P < 0.05). β-Adrenergic blockade also normalized calcitriol-stimulated PRA. Cyclooxygenase-2 inhibition had no effect on calcitriol-stimulated PRA. Our data demonstrate that vitamin D increases PRA independently of plasma Ca2+ via hypercalciuria, polyuria, hypovolemia, and increased β-adrenergic activity. PMID:23926179
Porcine intact and wounded skin responses to atmospheric nonthermal plasma.
Wu, Andrew S; Kalghatgi, Sameer; Dobrynin, Danil; Sensenig, Rachel; Cerchar, Ekaternia; Podolsky, Erica; Dulaimi, Essel; Paff, Michelle; Wasko, Kimberly; Arjunan, Krishna Priya; Garcia, Kristin; Fridman, Gregory; Balasubramanian, Manjula; Ownbey, Robert; Barbee, Kenneth A; Fridman, Alexander; Friedman, Gary; Joshi, Suresh G; Brooks, Ari D
2013-01-01
Thermal plasma is a valued tool in surgery for its coagulative and ablative properties. We suggested through in vitro studies that nonthermal plasma can sterilize tissues, inactive pathogens, promote coagulation, and potentiate wound healing. The present research was undertaken to study acute toxicity in porcine skin tissues. We demonstrate that floating electrode-discharge barrier discharge (FE-DBD) nonthermal plasma is electrically safe to apply to living organisms for short periods. We investigated the effects of FE-DBD plasma on Yorkshire pigs on intact and wounded skin immediately after treatment or 24h posttreatment. Macroscopic or microscopic histological changes were identified using histological and immunohistochemical techniques. The changes were classified into four groups for intact skin: normal features, minimal changes or congestive changes, epidermal layer damage, and full burn and into three groups for wounded skin: normal, clot or scab, and full burn-like features. Immunohistochemical staining for laminin layer integrity showed compromise over time. A marker for double-stranded DNA breaks, γ-H2AX, increased over plasma-exposure time. These findings identified a threshold for plasma exposure of up to 900s at low power and <120s at high power. Nonthermal FE-DBD plasma can be considered safe for future studies of external use under these threshold conditions for evaluation of sterilization, coagulation, and wound healing. Copyright © 2013 Elsevier Inc. All rights reserved.
Effects of kidney or kidney-pancreas transplantation on plasma pentosidine.
Hricik, D E; Schulak, J A; Sell, D R; Fogarty, J F; Monnier, V M
1993-02-01
Tissue and plasma concentrations of pentose-derived glycation end-products ("pentosidine") are elevated in diabetic patients with normal renal function and in both diabetic and nondiabetic patients with end-stage renal disease. To determine the effects of correcting hyperglycemia and/or renal failure on the accumulation of pentosidine, we used reverse phase and ion exchange high performance liquid chromatography to measure this advanced glycation end-product in plasma proteins of diabetic and nondiabetic transplant recipients at various time intervals after kidney-pancreas or kidney transplantation. Changes in plasma pentosidine levels after transplantation were compared to changes in simultaneously obtained glycohemoglobin levels. Both kidney and kidney-pancreas transplantation were accompanied by a dramatic, but incomplete, reduction of plasma pentosidine concentrations within three months of transplantation. Kidney-pancreas transplantation resulted in normal glycohemoglobin levels within three months but offered no advantage over kidney transplantation alone in the partial correction of plasma pentosidine levels. There was no correlation between posttransplant plasma pentosidine and glycohemoglobin levels in either diabetic or nondiabetic transplant recipients. We conclude that renal failure is the major factor accounting for the accumulation of pentosidine in both diabetic and nondiabetic patients with end-stage renal disease. Restoration of euglycemia after kidney-pancreas transplantation provides no additional benefit in reducing plasma pentosidine levels to that achieved by correction of renal failure after kidney transplantation alone.
Influence of the normal modes on the plasma uniformity in large scale CCP reactors
NASA Astrophysics Data System (ADS)
Eremin, Denis; Brinkmann, Ralf Peter; Mussenbrock, Thomas; Lane, Barton; Matsukuma, Masaaki; Ventzek, Peter
2016-09-01
Large scale capacitively coupled plasmas (CCP) driven by sources with high frequency components often exhibit phenomena which are absent in relatively well understood small scale CCPs driven at low frequencies. Of particular interest are such phenomena which affect discharge parameters of direct relevance to the plasma processing applications. One of such parameters is plasma uniformity. By using a self-consistent 2d3v Particle-in-cell/Monte-Carlo (PIC/MCC) code parallelized on GPU we have been able to show that uniformity of the plasma generated is influenced predominantly by two factors, the ionization pattern caused by high-energy electrons and the average temperature of low-energy plasma electrons. The heating mechanisms for these two groups of electrons appear to be different leading to different transversal (radial) profiles of the corresponding factors, which is well captured by the kinetic PIC/MCC code. We find that the heating mechanisms are intrinsically connected with excitation of normal modes inherent to a plasma-filled CCP reactor. In this work we study the wave nature of these phenomena, such as their excitation, propagation, and interaction with electrons. Supported by SFB-TR 87 project of the German Research Foundation and by the ``Experimental and numerical analysis of very high frequency capacitively coupled plasma discharges'' mutual research project between RUB and Tokyo Electron Ltd.
A tandem mirror hybrid plume plasma propulsion facility
NASA Technical Reports Server (NTRS)
Chang-Diaz, F. R.; Yang, T. F.; Krueger, W. A.; Peng, S.; Urbahn, J.; Yao, X.; Griffin, D.
1988-01-01
A concept in electrodeless plasma propulsion, which is also capable of delivering a variable Isp, is presented. The concept involves a three-stage system of plasma injection, heating, and subsequent ejection through a magnetic nozzle. The nozzle produces the hybrid plume by the coaxial injection of hypersonic neutral gas. The gas layer, thus formed, protects the material walls from the hot plasma and, through increased collisions, helps detach it from the diverging magnetic field. The physics of this concept is evaluated numerically through full spatial and temporal simulations; these explore the operating characteristics of such a device over a wide region of parameter space. An experimental facility to study the plasma dynamics in the hybrid plume was built. The device consists of a tandem mirror operating in an asymmetric mode. A later upgrade of this system will incorporate a cold plasma injector at one end of the machine. Initial experiments involve the full characterization of the operating envelope, as well as extensive measurements of plasma properties at the exhaust. The results of the numerical simulations are described.
Overview of the preliminary design of the ITER plasma control system
DOE Office of Scientific and Technical Information (OSTI.GOV)
Snipes, J. A.; Albanese, R.; Ambrosino, G.
An overview of the Preliminary Design of the ITER Plasma Control System (PCS) is described here, which focusses on the needs for 1st plasma and early plasma operation in hydrogen/helium (H/He) up to a plasma current of 15 MA with moderate auxiliary heating power in low confinement mode (L-mode). Candidate control schemes for basic magnetic control, including divertor operation and kinetic control of the electron density with gas puffing and pellet injection, were developed. Commissioning of the auxiliary heating systems is included as well as support functions for stray field topology and real-time plasma boundary reconstruction. Initial exception handling schemesmore » for faults of essential plant systems and for disruption protection were developed. The PCS architecture was also developed to be capable of handling basic control for early commissioning and the advanced control functions that will be needed for future high performance operation. A plasma control simulator is also being developed to test and validate control schemes. To handle the complexity of the ITER PCS, a systems engineering approach has been adopted with the development of a plasma control database to keep track of all control requirements.« less
Overview of the preliminary design of the ITER plasma control system
NASA Astrophysics Data System (ADS)
Snipes, J. A.; Albanese, R.; Ambrosino, G.; Ambrosino, R.; Amoskov, V.; Blanken, T. C.; Bremond, S.; Cinque, M.; de Tommasi, G.; de Vries, P. C.; Eidietis, N.; Felici, F.; Felton, R.; Ferron, J.; Formisano, A.; Gribov, Y.; Hosokawa, M.; Hyatt, A.; Humphreys, D.; Jackson, G.; Kavin, A.; Khayrutdinov, R.; Kim, D.; Kim, S. H.; Konovalov, S.; Lamzin, E.; Lehnen, M.; Lukash, V.; Lomas, P.; Mattei, M.; Mineev, A.; Moreau, P.; Neu, G.; Nouailletas, R.; Pautasso, G.; Pironti, A.; Rapson, C.; Raupp, G.; Ravensbergen, T.; Rimini, F.; Schneider, M.; Travere, J.-M.; Treutterer, W.; Villone, F.; Walker, M.; Welander, A.; Winter, A.; Zabeo, L.
2017-12-01
An overview of the preliminary design of the ITER plasma control system (PCS) is described here, which focusses on the needs for 1st plasma and early plasma operation in hydrogen/helium (H/He) up to a plasma current of 15 MA with moderate auxiliary heating power in low confinement mode (L-mode). Candidate control schemes for basic magnetic control, including divertor operation and kinetic control of the electron density with gas puffing and pellet injection, were developed. Commissioning of the auxiliary heating systems is included as well as support functions for stray field topology and real-time plasma boundary reconstruction. Initial exception handling schemes for faults of essential plant systems and for disruption protection were developed. The PCS architecture was also developed to be capable of handling basic control for early commissioning and the advanced control functions that will be needed for future high performance operation. A plasma control simulator is also being developed to test and validate control schemes. To handle the complexity of the ITER PCS, a systems engineering approach has been adopted with the development of a plasma control database to keep track of all control requirements.
Overview of the preliminary design of the ITER plasma control system
Snipes, J. A.; Albanese, R.; Ambrosino, G.; ...
2017-09-11
An overview of the Preliminary Design of the ITER Plasma Control System (PCS) is described here, which focusses on the needs for 1st plasma and early plasma operation in hydrogen/helium (H/He) up to a plasma current of 15 MA with moderate auxiliary heating power in low confinement mode (L-mode). Candidate control schemes for basic magnetic control, including divertor operation and kinetic control of the electron density with gas puffing and pellet injection, were developed. Commissioning of the auxiliary heating systems is included as well as support functions for stray field topology and real-time plasma boundary reconstruction. Initial exception handling schemesmore » for faults of essential plant systems and for disruption protection were developed. The PCS architecture was also developed to be capable of handling basic control for early commissioning and the advanced control functions that will be needed for future high performance operation. A plasma control simulator is also being developed to test and validate control schemes. To handle the complexity of the ITER PCS, a systems engineering approach has been adopted with the development of a plasma control database to keep track of all control requirements.« less
Operation Results of the Kstar Helium Refrigeration System
NASA Astrophysics Data System (ADS)
Chang, H.-S.; Fauve, E.; Park, D.-S.; Joo, J.-J.; Moon, K.-M.; Cho, K.-W.; Na, H. K.; Kwon, M.; Yang, S.-H.; Gistau-Baguer, G.
2010-04-01
The "first plasma" (100 kA of controllable plasma current for 100 ms) of KSTAR has been successfully generated in July 2008. The major outstanding feature of KSTAR compared to most other Tokamaks is that all the magnet coils are superconducting (SC), which enables higher plasma current values for a longer time duration when the nominal operation status has been reached. However, to establish the operating condition for the SC coils, other cold components, such as thermal shields, coil-supporting structures, SC buslines, and current leads also must be maintained at proper cryogenic temperature levels. A helium refrigeration system (HRS) with an exergetic equivalent cooling power of 9 kW at 4.5 K has been installed for such purposes and successfully commissioned. In this proceeding, we will report on the operation results of the HRS during the first plasma campaign of KSTAR. Using the HRS, the 300-ton cold mass of KSTAR was cooled down from ambient to the operating temperature levels of each cold component. Stable and steady cryogenic conditions, proper for the generation of the "first plasma" have been maintained for three months, after which, all of the cold mass was warmed up again to ambient temperature.
NASA Astrophysics Data System (ADS)
Brcka, Jozef
2016-07-01
A multi inductively coupled plasma (ICP) system can be used to maintain the plasma uniformity and increase the area processed by a high-density plasma. This article presents a source in two different configurations. The distributed planar multi ICP (DM-ICP) source comprises individual ICP sources that are not overlapped and produce plasma independently. Mutual coupling of the ICPs may affect the distribution of the produced plasma. The integrated multicoil ICP (IMC-ICP) source consists of four low-inductance ICP antennas that are superimposed in an azimuthal manner. The identical geometry of the ICP coils was assumed in this work. Both configurations have highly asymmetric components. A three-dimensional (3D) plasma model of the multicoil ICP configurations with asymmetric features is used to investigate the plasma characteristics in a large chamber and the operation of the sources in inert and reactive gases. The feasibility of the computational calculation, the speed, and the computational resources of the coupled multiphysics solver are investigated in the framework of a large realistic geometry and complex reaction processes. It was determined that additional variables can be used to control large-area plasmas. Both configurations can form a plasma, that azimuthally moves in a controlled manner, the so-called “sweeping mode” (SM) or “polyphase mode” (PPM), and thus they have the potential for large-area and high-density plasma applications. The operation in the azimuthal mode has the potential to adjust the plasma distribution, the reaction chemistry, and increase or modulate the production of the radicals. The intrinsic asymmetry of the individual coils and their combined operation were investigated within a source assembly primarily in argon and CO gases. Limited investigations were also performed on operation in CH4 gas. The plasma parameters and the resulting chemistry are affected by the geometrical relation between individual antennas. The aim of this work is to incorporate the technological, computational, dimensional scaling, and reaction chemistry aspects of the plasma under one computational framework. The 3D simulation is utilized to geometrically scale up the reactive plasma that is produced by multiple ICP sources.
Zhang, Hong-Feng; Dai, Yu-Chuan; Wu, Jing; Jia, Mei-Xiang; Zhang, Ji-Shui; Shou, Xiao-Jing; Han, Song-Ping; Zhang, Rong; Han, Ji-Sheng
2016-10-01
Autism spectrum disorder (ASD) is defined by impairments of social interaction and the presence of obsessive behaviors. The "twin" nonapeptides oxytocin (OXT) and arginine-vasopressin (AVP) are known to play regulatory roles in social behaviors. However, the plasma levels and behavioral relevance of OXT and AVP in children with ASD have seldom been investigated. It is also unknown whether their mothers have abnormal plasma peptide levels. Here, using well-established methods of neuropeptide measurement and a relatively large sample size, we determined the plasma levels of the two neuropeptides in 85 normal children, 84 children with ASD, and 31 mothers from each group of children. As expected, children with ASD had lower plasma OXT levels than gender-matched controls (P = 0.028). No such difference was found for plasma AVP concentrations. Correlation analysis showed that ASD children with higher plasma OXT concentrations tended to have less impairment of verbal communication (Rho = -0.22, P = 0.076), while those with higher plasma AVP levels tended to have lower levels of repetitive use of objects (Rho = -0.231, P = 0.079). Unlike the findings in children, maternal plasma OXT levels showed no group difference. However, plasma AVP levels in the mothers of ASD children tended to be lower than in the mothers of normal children (P = 0.072). In conclusion, our results suggest that the OXT system is dysregulated in children with ASD, and that OXT and AVP levels in plasma seem to be associated with specific autistic symptoms. The plasma levels of OXT or AVP in mothers and their ASD children did not seem to change in the same direction.
Resonant-frequency discharge in a multi-cell radio frequency cavity
DOE Office of Scientific and Technical Information (OSTI.GOV)
Popovic, S; Upadhyay, J; Mammosser, J
2014-11-07
We are reporting experimental results on microwave discharge operating at resonant frequency in a multi-cell radio frequency (RF) accelerator cavity. Although the discharge operated at room temperature, the setup was constructed so that it could be used for plasma generation and processing in fully assembled active superconducting radio-frequency (SRF) cryomodule (in situ operation). This discharge offers an efficient mechanism for removal of a variety of contaminants, organic or oxide layers, and residual particulates from the interior surface of RF cavities through the interaction of plasma-generated radicals with the cavity walls. We describe resonant RF breakdown conditions and address the problemsmore » related to generation and sustaining the multi-cell cavity plasma, which are breakdown and resonant detuning. We have determined breakdown conditions in the cavity, which was acting as a plasma vessel with distorted cylindrical geometry. We discuss the spectroscopic data taken during plasma removal of contaminants and use them to evaluate plasma parameters, characterize the process, and estimate the volatile contaminant product removal.« less
Plasma ``anti-assistance'' and ``self-assistance'' to high power impulse magnetron sputtering
NASA Astrophysics Data System (ADS)
Anders, André; Yushkov, Georgy Yu.
2009-04-01
A plasma assistance system was investigated with the goal to operate high power impulse magnetron sputtering (HiPIMS) at lower pressure than usual, thereby to enhance the utilization of the ballistic atoms and ions with high kinetic energy in the film growth process. Gas plasma flow from a constricted plasma source was aimed at the magnetron target. Contrary to initial expectations, such plasma assistance turned out to be contraproductive because it led to the extinction of the magnetron discharge. The effect can be explained by gas rarefaction. A better method of reducing the necessary gas pressure is operation at relatively high pulse repetition rates where the afterglow plasma of one pulse assists in the development of the next pulse. Here we show that this method, known from medium-frequency (MF) pulsed sputtering, is also very important at the much lower pulse repetition rates of HiPIMS. A minimum in the possible operational pressure is found in the frequency region between HiPIMS and MF pulsed sputtering.
Characteristics of the NASA Lewis bumpy-torus plasma generated with positive applied potentials
NASA Technical Reports Server (NTRS)
Roth, J. R.; Gerdin, G. A.; Richardson, R. W.
1976-01-01
Experimental observations were made during steady-state operation of a bumpy-torus plasma at input powers up to 150 kW in deuterium and helium gas and with positive potentials applied to the midplane electrodes. In this steady-state ion heating method a modified Penning discharge is operated such that the plasma is acted upon by a combination of strong electric and magnetic fields. Experimental investigation of a deuterium plasma revealed electron temperatures from 14 to 140 eV and ion kinetic temperatures from 160 to 1785 eV. At least two distinct modes of operation exist. Experimental data shows that the average ion residence time in the plasma is virtually independent of the magnetic field strength. Data was taken when all 12 anode rings were at high voltage, and in other symmetric configurations in which the toroidal plasma was generated by applying positive potentials to six anode rings, three anode rings, and a single anode ring.