Ong Tan, Kendrich Graemer
2017-09-01
The present study aimed to investigate the contact quotient (CQ) values of breathy, normal, and pressed phonation types in four different sections of the female singing range. Electroglottography (EGG) and acoustic signals were recorded from 10 female singing teachers. Five vowels were sung for 1-3 seconds each, in three phonation types-normal, breathy, and pressed, in four pitches representing registration change points in the singing range. CQ values were automatically generated from the EGG signal using VoceVista at 35% threshold level. Sound pressure levels were checked in Praat. Unianova and correlations were performed using an SPSS program. CQ values of female participants in the study yielded ranges of 0.25-0.62 in normal and 0.34-0.73 in pressed. Normal and pressed CQ differed significantly from each other at P < 0.00. Breathy samples were not viable for analysis. A concentration of CQ values from 0.5 to 0.6 of both pressed low and pressed break samples was noted, but CQ values across the pitch range showed no significant trend. Normal and pressed phonation CQ values beyond the speaking pitch varied among the subjects. Pressed phonation CQ values were mostly higher, but the values were only relative to the corresponding normal phonation on the same pitch. Other measurements may be more suitable for measuring vocal fold impact stress in higher frequencies, thus, distinguishing normal from pressed singing. Copyright © 2017 The Voice Foundation. Published by Elsevier Inc. All rights reserved.
Normal value range is 105 to 333 international units per liter (IU/L). Normal value ranges may vary slightly among different laboratories. Some labs use different measurements or test different samples. Talk to your provider about ...
... Normal Results Normal values are 60% to 150% inhibition. Normal value ranges may vary slightly among different ... Health Solutions. About MedlinePlus Site Map FAQs Customer Support Get email updates Subscribe to RSS Follow us ...
... Normal Results Normal values are 60% to 150% inhibition. Normal value ranges may vary slightly among different ... Health Solutions. About MedlinePlus Site Map FAQs Customer Support Get email updates Subscribe to RSS Follow us ...
48 CFR 215.404-71-1 - General.
Code of Federal Regulations, 2010 CFR
2010-10-01
... range provides values based on above normal or below normal conditions. In the price negotiation..., DEPARTMENT OF DEFENSE CONTRACTING METHODS AND CONTRACT TYPES CONTRACTING BY NEGOTIATION Contract Pricing 215... contracting officer assigns values to each profit factor; the value multiplied by the base results in the...
Diffusion-weighted MR imaging: role in the differential diagnosis of breast lesions.
Altay, C; Balci, P; Altay, S; Karasu, S; Saydam, S; Canda, T; Dicle, O
2014-01-01
To evaluate the diagnostic value of magnetic resonance diffusion-weighted imaging (DWI) using apparent diffusion coefficient (ADC) values to the characterization of breast lesions and differentiation of benign and malignant lesions. Thirty-seven women (mean age, 38 years) with 37 enrolled in the study. DWI and ADC maps in the axial plane were obtained using a 1.5 Tesla MRI device. Mean ADC measurements were calculated among cysts, normal fibroglandular tissue, benign lesions and malignant lesions were evaluated. Out of 37 women, 4 had normally breast MRI findings. The diagnosis of remaining 33 patients with 37 breast lesions were as follows; malign lesions (n = 23), benign lesions (n = 10) and simple breast cyst (n = 4). The ADC values were as follows (in units of 10(-3) mm2/s): Normal fibroglandular tissue (range: 1.39-2.06; mean: 1.61 ± 0.23), benign breast lesions (range: 1.09-1.76; mean: 1.47 ± 0.25), cyts (range: 2.27-2.46, mean: 2.37 ± 0.07) and malignant breast lesions (range: 0.78-1.26, mean: 0.96 ± 0.25). The mean ADC obtained from malignant breast lesions was statistically different from that observed in benign solid lesions (p < < 0.01) and normal fibroglandular breast tissue (p < 0.01). Furthermore, the mean ADC values of benign breast lesions was not statistically different from cyst (p ≥ 0.01) and normal fibroglandular breast tissue (p ≥ 0.01). A ADC value of 1.1 x 10(-3) mm'/s as a treshold value provided differantiation for malign and benign lesions, with a sensitivity of 91.3% and a specificity of 85.7% compared with conventional breast MRI values. DWI with quantitative ADC measurements is a reliable tool for differentiation of benign and malignant breast lesions.
The normal range is 3.4 to 5.4 g/dL (34 to 54 g/L). Normal value ranges may vary slightly among different laboratories. Some labs use different measurements or test different samples. Talk to your provider about ...
Aspartate aminotransferase (AST) blood test
The normal range is 10 to 34 U/L (0.17 to 0.57 µkat/L). Normal value ranges may vary slightly among different laboratories. Some labs use different measurements or may test different samples. Talk to your health ...
... is also used to screen newborn babies for cystic fibrosis. Normal Results Normal value ranges may vary slightly ... to: Abnormal production of pancreatic enzymes Acute pancreatitis Cystic fibrosis Pancreatic cancer Low or normal levels may be ...
The normal range is 40 to 140 units per liter (U/L) or 0.38 to 1.42 microkat/L (µkat/L). Note: Normal value ranges may vary slightly among different laboratories. Talk to your provider about the meaning of your specific test results. The examples ...
Cerebral spinal fluid (CSF) collection
... establish the diagnosis of normal pressure hydrocephalus. Normal Results Normal values typically range as follows: Pressure: 70 ... measurements or may test different specimens. What Abnormal Results Mean If the CSF looks cloudy, it could ...
Pinnock, Farena; Parlar, Melissa; Hawco, Colin; Hanford, Lindsay; Hall, Geoffrey B.
2017-01-01
This study assessed whether cortical thickness across the brain and regionally in terms of the default mode, salience, and central executive networks differentiates schizophrenia patients and healthy controls with normal range or below-normal range cognitive performance. Cognitive normality was defined using the MATRICS Consensus Cognitive Battery (MCCB) composite score (T = 50 ± 10) and structural magnetic resonance imaging was used to generate cortical thickness data. Whole brain analysis revealed that cognitively normal range controls (n = 39) had greater cortical thickness than both cognitively normal (n = 17) and below-normal range (n = 49) patients. Cognitively normal controls also demonstrated greater thickness than patients in regions associated with the default mode and salience, but not central executive networks. No differences on any thickness measure were found between cognitively normal range and below-normal range controls (n = 24) or between cognitively normal and below-normal range patients. In addition, structural covariance between network regions was high and similar across subgroups. Positive and negative symptom severity did not correlate with thickness values. Cortical thinning across the brain and regionally in relation to the default and salience networks may index shared aspects of the psychotic psychopathology that defines schizophrenia with no relation to cognitive impairment. PMID:28348889
Henriksen, J H; Kok-Jensen, A
1984-04-01
The overall extravasation rate of albumin, TER (i.e. the fraction of the intravascular albumin mass (IVM) passing into, and during steady state returning from, the extravascular space per unit time) was determined from the disappearance of i.v. injected radioiodinated serum albumin in seven patients with severe chronic obstructive lung disease (COLD) and in seven normal controls. Arterial oxygen tension in patients with COLD was median 60 mmHg (range 47-80, normal greater than 75 mmHg), vital capacity was on the average 55% of expected normal value (median 1.80 litre, range 1.45-1.95), and forced expired volume in first sec was decreased to 21% of expected normal value (median 0.55 litre, range 0.40-0.70). Right-heart catheterization revealed pulmonary hypertension in all but one patient. TER in patients with COLD was median 6.1% IVM/h (range 3.5-10.1) as compared to that of normal controls 6.0% IVM/h (range 4.3-7.4), indicating that no significant change in microvascular leakiness to albumin could be found in patients with COLD. Thus, the results bring no support to a generally increased microvascular permeability to proteins in patients with COLD.
Triiodothyronine and thyroxine in urine. I. Measurement and application.
Shakespear, R A; Burke, C W
1976-03-01
Urinary triiodothyronine (T3) and thyroxine (T4) were measured by RIA, and T4 was also measured by competitive protein binding (CPB). pH 1-hydrolysable conjugates were 48% of total urinary T3, and enzyme- or pH 1-hydrolysable conjugates were 55% and 61% of total urinary T4. The mean unconjugated T3 excretion was 34.3 ng/h (0.99 mug T3/g creatinine) in normal subjects (no day-night rhythm found), 1.56 mug/g in late pregnancy, 0.82 mug/g in neonates (1-12 days), and was also unchanged in persons with high or low thyroxine-binding globulin (TBG). In thyrotoxicosis, mean T3 excretion was 281 ng/h, no values being in the normal range. In primary hypothyroidism it was 18.3 ng/h, but over half the values were in the normal range. The mean urinary unconjugated T4 was 82.2 ng/h (1.37 mug T4/g creatinine) in normal subjects, 1.6 mug/g in neonates, and unchanged in persons with high or low TBG, except that in pregnancy high values were compatible with increases protein excretion. Apparently increased day-time T4 excretion compared with night-time excretion may also be due to changes in protein excretion rate. The mean T4 in thyrotoxicosis was 337 ng/h (12% of values in the normal range) and 32.8 ng/h in primary hypothyroidism (over half the normal range). All the assays, especially that of T4 by CPB gave readings which were incorrect with protein concentrations above 100 mg/l. Urinary T3 and T4 assays for clinical purposes have few practical advantages over serum assays, despite the relationship of urine T3 and T4 to serum unbound levels.
Selk Ghaffari, Masoud; Sabzevari, Amin; Ghamsari, SeyedMehdi; Shad, Hussein
2017-11-25
This study was conducted to establish normal reference range for the Schirmer tear test (STT) and intraocular pressure (IOP) in clinically normal donkeys for use in clinical practice. Sixteen adult Ethiopian domestic donkeys were used in this study. Complete ophthalmic examinations were performed without chemical restraint. STT values were evaluated in both eyes of all donkeys using a commercial STT strip. IOP was measured in both eyes with a Tono-Pen Vet (Reichert. USA) without using regional nerve blocks. STT values for all eyes (n=32) were 22.1±6.9 mm/minute with a range of 13-35 mm/minute. Comparison of mean STT values between right (n=16) and left eyes (n=16) showed no differences (P=0.6). Mean ±sd IOP values by applanation tonometry were 17.8±3.7 mmHg (range 13.5-24.5 mmHg). Comparison of mean IOP values between right (n=16) and left eyes (n=16) showed no differences (P=0.7). This initial survey provides means and ranges for IOP and STT values in donkeys. These data will assist veterinary ophthalmologists in more accurate diagnosis and management of ophthalmic diseases in donkeys, including keratoconjunctivitis sicca and glaucoma. © British Veterinary Association (unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Energy balance studies and plasma catecholamine values for patients with healed burns.
Wallace, B H; Cone, J B; Caldwell, F T
1991-01-01
We report heat balance studies and plasma catecholamine values for 49 children and young adults with healed burn wounds (age range 0.6 to 31 years and burn range 1% to 82% body surface area burned; mean 41%). All measurements were made during the week of discharge. Heat production for patients with healed burns was not significantly different from predicted normal values. However, compartmented heat loss demonstrated a persistent increment in evaporative heat loss that was secondary to continued elevation of cutaneous water vapor loss immediately after wound closure. A reciprocal decrement in dry heat loss was demonstrated (as a result of a cooler average surface temperature, 0.84 degree C cooler than the average integrated skin temperature of five normal volunteers who were studied in our unit under similar environmental conditions). Mean values for plasma catecholamines were in the normal range: epinephrine = 56 +/- 37 pg/ml, norepinephrine = 385 +/- 220 pg/ml, and dopamine = 34 +/- 29 pg/ml. In conclusion, patients with freshly healed burn wounds have normal rates of heat production; however, there is a residual increment in transcutaneous water vapor loss, which produces surface cooling and decreased average surface temperature, which in turn lowers dry heat loss by an approximately equivalent amount.
Method and system for monitoring and displaying engine performance parameters
NASA Technical Reports Server (NTRS)
Abbott, Terence S. (Inventor); Person, Jr., Lee H. (Inventor)
1991-01-01
The invention is a method and system for monitoring and directly displaying the actual thrust produced by a jet aircraft engine under determined operating conditions and the available thrust and predicted (commanded) thrust of a functional model of an ideal engine under the same determined operating conditions. A first set of actual value output signals representative of a plurality of actual performance parameters of the engine under the determined operating conditions is generated and compared with a second set of predicted value output signals representative of the predicted value of corresponding performance parameters of a functional model of the engine under the determined operating conditions to produce a third set of difference value output signals within a range of normal, caution, or warning limit values. A thrust indicator displays when any one of the actual value output signals is in the warning range while shaping function means shape each of the respective difference output signals as each approaches the limit of the respective normal, caution, and warning range limits.
Manevska, Nevena; Stojanoski, Sinisa; Pop Gjorceva, Daniela; Todorovska, Lidija; Miladinova, Daniela; Zafirova, Beti
2017-09-01
Introduction Muscle perfusion is a physiologic process that can undergo quantitative assessment and thus define the range of normal values of perfusion indexes and perfusion reserve. The investigation of the microcirculation has a crucial role in determining the muscle perfusion. Materials and method The study included 30 examinees, 24-74 years of age, without a history of confirmed peripheral artery disease and all had normal findings on Doppler ultrasonography and pedo-brachial index of lower extremity (PBI). 99mTc-MIBI tissue muscle perfusion scintigraphy of lower limbs evaluates tissue perfusion in resting condition "rest study" and after workload "stress study", through quantitative parameters: Inter-extremity index (for both studies), left thigh/right thigh (LT/RT) left calf/right calf (LC/RC) and perfusion reserve (PR) for both thighs and calves. Results In our investigated group we assessed the normal values of quantitative parameters of perfusion indexes. Indexes ranged for LT/RT in rest study 0.91-1.05, in stress study 0.92-1.04. LC/RC in rest 0.93-1.07 and in stress study 0.93-1.09. The examinees older than 50 years had insignificantly lower perfusion reserve of these parameters compared with those younger than 50, LC (p=0.98), and RC (p=0.6). Conclusion This non-invasive scintigraphic method allows in individuals without peripheral artery disease to determine the range of normal values of muscle perfusion at rest and stress condition and to clinically implement them in evaluation of patients with peripheral artery disease for differentiating patients with normal from those with impaired lower limbs circulation.
Barsties, Ben; Verfaillie, Rudi; Roy, Nelson; Maryn, Youri
2013-01-01
To analyze the impact of body weight and body fat volume on selected parameters of vocal quality, phonatory range, and aerodynamics in females. Based on measurements of body mass index in combination with body fat volume, 29 normophonic female subjects were classified as normal weight, underweight, and obese. Voice quality was investigated via auditory-perceptual ratings of breathiness, roughness, and overall dysphonia severity, via various acoustic measures and a multiparametric index. Phonatory range performance was examined using selected measures of the voice range profile and speech range profile. Measures of vocally relevant aerodynamics included vital capacity (i.e., VC), expected VC, phonation quotient, and maximum phonation time (i.e., MPT). Significant differences between the three weight groups were found across several measures of intensity, VC, MPT, and shimmer. As compared to the other groups, significantly higher values of maximum and minimum intensity levels, as well as sound pressure level during habitual running speech were observed for the obese group (all p-values<0.05); whereas, the underweight group had significantly lower values for VC and ratio of expected to measured VC (p-values<0.01). Furthermore, underweight subjects differed significantly as compared to normal weight subjects with lower MPT (p=0.025) and higher lowest-F0 (p=0.035). Finally the obese group showed significantly lower shimmer values than the normal weight subjects (p<0.05). Body weight and body fat volume appear to influence select objective measures of voice quality, vocal aerodynamics, and phonatory range performance.
A normal result means there was no growth of microorganisms on the lab dish. Normal value ranges may vary slightly among different laboratories. Talk to your doctor about the meaning of your specific test results.
... thinning medicine does not work. Normal Results Normal value ranges may vary slightly among different laboratories. Talk ... to the principles of the Health on the Net Foundation (www.hon.ch). The information provided herein ...
... a child's head circumference. Normal ranges for a child's sex and age (weeks, months), based on values that experts have obtained for normal growth rates of infants' and children's heads. Measurement of the head circumference is an ...
Archer, D F; Thomas, M A; Conard, J; Merkatz, R B; Creasy, G W; Roberts, K; Plagianos, M; Blithe, D; Sitruk-Ware, R
2016-01-01
Estrogen-sensitive hepatic proteins were assessed in women using a contraceptive vaginal ring (CVR) delivering 150mcg Nestorone® (NES) and 15mcg ethinyl estradiol (EE). A substudy of the Contraceptive Clinical Trials Network of the National Institute of Child Health and Human Development enrolled 129 participants, with assessments of factor VIII, fibrinogen, protein S (PS) and sex hormone binding globulin (SHBG). Thirty-six participants had used combined hormonal contraceptives (CHCs) in the cycle preceding first CVR use (recent users) and 70 had no history of recent use (nonusers). Mean values at baseline were within the normal range for all four proteins but were higher for factor VIII, fibrinogen and SHBG and significantly lower for PS in recent compared to nonusers. During NES/EE CVR use, factor VIII, fibrinogen and PS were within the normal range; however, SHBG levels were increased by nearly 100% at Cycle 13. The change from baseline to final evaluation was statistically significant for all proteins in nonusers. The change in recent users was significant for factor VIII at Cycle 6 and for SHBG at Cycles 6 and 13, but not for PS or fibrinogen. NES/EE CVR for up to 13cycles was associated with changes from baseline in plasma levels of factor VIII, fibrinogen and PS that were within the normal range, with SHBG levels above the normal range by Cycle 6. Nonusers of CHC before CVR showed wider changes in values versus recent users whose baseline values were increased by previous EE exposure. Recent use of CHCs demonstrated significant changes in all four measured hepatic proteins at baseline compared to nonusers. Use of the NES/EE CVR further changed these hepatic protein markers, but values remained within the normal range. Prebaseline exposure to estrogen can obscure interpretation of hepatic proteins changes associated with a second CHC. Copyright © 2016 Elsevier Inc. All rights reserved.
Quantitative analysis of rectal cancer by spectral domain optical coherence tomography
NASA Astrophysics Data System (ADS)
Zhang, Q. Q.; Wu, X. J.; Tang, T.; Zhu, S. W.; Yao, Q.; Gao, Bruce Z.; Yuan, X. C.
2012-08-01
To quantify OCT images of rectal tissue for clinic diagnosis, the scattering coefficient of the tissue is extracted by curve fitting the OCT signals to a confocal single model. A total of 1000 measurements (half and half of normal and malignant tissues) were obtained from 16 recta. The normal rectal tissue has a larger scattering coefficient ranging from 1.09 to 5.41 mm-1 with a mean value of 2.29 mm-1 (std:±0.32), while the malignant group shows lower scattering property and the values ranging from 0.25 to 2.69 mm-1 with a mean value of 1.41 mm-1 (std:±0.18). The peri-cancer of recta has also been investigated to distinguish the difference between normal and malignant rectal tissue. The results demonstrate that the quantitative analysis of the rectal tissue can be used as a promising diagnostic criterion of early rectal cancer, which has great value for clinical medical applications.
Akin, M; Sarbay, H; Guler, S; Balci, Y I; Polat, A
2016-04-01
We evaluated that response to parenteral iron therapy could be helpful in distinguishing the types of iron deficiency anemia. This study analyzed responses to IV iron sucrose therapy of 15 children with unexplained refractory iron deficiency anemia (URIDA). We compared the results at diagnosis, 6 weeks and 6 months after the therapy. Results were compared with responses of 11 patients' results with iron-refractory iron deficiency anemia (IRIDA) from our previous study. Six weeks after the start of treatment, ferritin, MCV, MCH and Hb values were in normal range in 10 patients. The increase in Hb, MCH, MCV, and ferritin values ranged 2.6-3.5 g/dL, 1.7-4.2 pg, 2-9 fL, and 13-25 ng/mL, respectively. In five patients, Hb, MCH, and MCV mean (range) values [11.2 g/dL (11-12.2), 24.5 pg (24-25.6), and 67 fL (65-70)] were nearly normal but ferritin mean (range) values [9.8 ng/mL (8-11)] were below normal. Six weeks after the start of treatment, Hb, MCH, MCV and ferritin values of patients with IRIDA were increased. The increase in Hb, MCH, MCV, and ferritin values ranged 0.8-2.7 g/dL, 1.7-4.2 pg, 2-9 fL, and 13-25 ng/mL, respectively. IRIDA is only partially responsive to parenteral iron supplementation. In conclusion, this study demonstrated that the response to intravenous iron therapy for the URIDA cases improved blood parameters more effectively than hereditary IRIDA. Response to parenteral iron therapy would be helpful to distinguish unexplained refractory IDA from hereditary IRIDA for clinicians who do not have access to hepcidin or TMPRS6 mutation analysis. © 2016 John Wiley & Sons Ltd.
Evaluation of Kurtosis into the product of two normally distributed variables
NASA Astrophysics Data System (ADS)
Oliveira, Amílcar; Oliveira, Teresa; Seijas-Macías, Antonio
2016-06-01
Kurtosis (κ) is any measure of the "peakedness" of a distribution of a real-valued random variable. We study the evolution of the Kurtosis for the product of two normally distributed variables. Product of two normal variables is a very common problem for some areas of study, like, physics, economics, psychology, … Normal variables have a constant value for kurtosis (κ = 3), independently of the value of the two parameters: mean and variance. In fact, the excess kurtosis is defined as κ- 3 and the Normal Distribution Kurtosis is zero. The product of two normally distributed variables is a function of the parameters of the two variables and the correlation between then, and the range for kurtosis is in [0, 6] for independent variables and in [0, 12] when correlation between then is allowed.
Hobbs, Brian P.; Chandler, Adam G.; Anderson, Ella F.; Herron, Delise H.; Charnsangavej, Chusilp; Yao, James
2013-01-01
Purpose To assess the effects of acquisition duration on computed tomographic (CT) perfusion parameter values in neuroendocrine liver metastases and normal liver tissue. Materials and Methods This retrospective study was institutional review board approved, with waiver of informed consent. CT perfusion studies in 16 patients (median age, 57.5 years; range, 42.0–69.7 years), including six men (median, 54.1 years; range, 42.0–69.7), and 10 women (median, 59.3 years; range 43.6–66.3), with neuroendocrine liver metastases were analyzed by means of distributed parametric modeling to determine tissue blood flow, blood volume, mean transit time, permeability, and hepatic arterial fraction for tumors and normal liver tissue. Analyses were undertaken with acquisition time of 12–590 seconds. Nonparameteric regression analyses were used to evaluate the functional relationships between CT perfusion parameters and acquisition duration. Evidence for time invariance was evaluated for each parameter at multiple time points by inferring the fitted derivative to assess its proximity to zero as a function of acquisition time by using equivalence tests with three levels of confidence (20%, 70%, and 90%). Results CT perfusion parameter values varied, approaching stable values with increasing acquisition duration. Acquisition duration greater than 160 seconds was required to obtain at least low confidence stability in any of the CT perfusion parameters. At 160 seconds of acquisition, all five CT perfusion parameters stabilized with low confidence in tumor and normal tissues, with the exception of hepatic arterial fraction in tumors. After 220 seconds of acquisition, there was stabilization with moderate confidence for blood flow, blood volume, and hepatic arterial fraction in tumors and normal tissue, and for mean transit time in tumors; however, permeability values did not satisfy the moderate stabilization criteria in both tumors and normal tissue until 360 seconds of acquisition. Blood flow, mean transit time, permeability, and hepatic arterial fraction were significantly different between tumor and normal tissue at 360 seconds (P < .001). Conclusion CT perfusion parameter values are affected by acquisition duration and approach progressively stable values with increasing acquisition times. © RSNA, 2013 Online supplemental material is available for this article. PMID:23824990
Normalization is a general neural mechanism for context-dependent decision making
Louie, Kenway; Khaw, Mel W.; Glimcher, Paul W.
2013-01-01
Understanding the neural code is critical to linking brain and behavior. In sensory systems, divisive normalization seems to be a canonical neural computation, observed in areas ranging from retina to cortex and mediating processes including contrast adaptation, surround suppression, visual attention, and multisensory integration. Recent electrophysiological studies have extended these insights beyond the sensory domain, demonstrating an analogous algorithm for the value signals that guide decision making, but the effects of normalization on choice behavior are unknown. Here, we show that choice models using normalization generate significant (and classically irrational) choice phenomena driven by either the value or number of alternative options. In value-guided choice experiments, both monkey and human choosers show novel context-dependent behavior consistent with normalization. These findings suggest that the neural mechanism of value coding critically influences stochastic choice behavior and provide a generalizable quantitative framework for examining context effects in decision making. PMID:23530203
Levy, Philip T.; Sanchez, Aura; Machefsky, Aliza; Fowler, Susan; Holland, Mark R.; Singh, Gautam K.
2014-01-01
Background Establishment of the range of normal values and associated variations of two-dimensional speckle-tracking echocardiography (2DSTE) derived right ventricular (RV) strain is a prerequisite for its routine clinical application in children. The objectives of this study were to perform a meta-analysis of normal ranges of RV longitudinal strain measurements derived by 2DSTE in children and identify confounders that may contribute to differences in reported measures. Methods A systematic review was launched in PubMed, Embase, Scopus, Cochrane, and ClinicTrials.gov. Search hedges were created to cover the concepts of pediatrics, speckle-tracking echocardiography, and right heart ventricle. Two investigators independently identified and included studies if they reported the 2DSTE derived RV strain measures: RV peak global longitudinal strain (pGLS), systolic strain rate (pGLSRs), early diastolic strain rate (pGLSRe), late diastolic strain rate (pGLSRa), or segmental longitudinal strain at the apical, mid, and basal ventricular levels in healthy children. Quality and reporting of the studies were assessed. The weighted mean was estimated by using random-effects with 95% confidence intervals (CI), heterogeneity was assessed by the Cochran's Q statistic and the inconsistency index (I2), and publication bias was evaluated using funnel plots and the Egger test. Effects of demographic, clinical, equipment, and software variables were assessed in a meta-regression. Results The search identified 226 children from 10 studies. The reported normal mean values of pGLS among the studies varied from −20.80% to −34.10% (mean, −29.03%, 95%CI, −31.52% to −26.54%), pGLSRs varied from −1.30 to −2.40 1/sec (mean, −1.88, 95%CI, −2.10 to −1.59), pGLSRe ranged from 1.7 to 2.69 1/sec (mean, 2.34, 95%CI, 2.00 to 2.67) and pGLSRa ranged from 1.00 to 1.30 1/sec (mean, 1.18, 95% CI, 1.04 to 1.33). A significant base-to-apex segmental strain gradient (p <0.05) was observed in the right ventricular free wall. There was significant between-study heterogeneity and inconsistency (I2>88% and p<0.01 for each strain measure), which was not explained by age, gender, body surface area, heart rate, frame rate, tissue tracking methodology, equipment, or software. The meta-regression showed that these effects were not significant determinants of variations among normal ranges of strain values. There was no evidence of publication bias (Egger test, p=0.59). Conclusions This study is the first to define normal values of two-dimensional speckle tracking echocardiographic (2DSTE) derived right ventricle strain in children on the basis of a meta-analysis. The normal mean value in children for RV global strain is −29.03% (95% CI, −31.52% to −26.54%). The normal mean value for RV global systolic strain rate is −1.88 1/sec (95% CI, −2.10 to −1.59). RV segmental strain has a stable base-to-apex gradient that highlights the dominance of deep longitudinal layers of the RV that are aligned base to apex. Variations among different normal ranges do not appear to be dependent on differences in demographic, clinical, or equipment parameters in this meta-analysis. All of the eligible studies used equipment and software from one manufacturer, General Electric (GE). PMID:24582163
Energy Index For Aircraft Maneuvers
NASA Technical Reports Server (NTRS)
Chidester, Thomas R. (Inventor); Lynch, Robert E. (Inventor); Lawrence, Robert E. (Inventor); Amidan, Brett G. (Inventor); Ferryman, Thomas A. (Inventor); Drew, Douglas A. (Inventor); Ainsworth, Robert J. (Inventor); Prothero, Gary L. (Inventor); Romanowski, Tomothy P. (Inventor); Bloch, Laurent (Inventor)
2006-01-01
Method and system for analyzing, separately or in combination, kinetic energy and potential energy and/or their time derivatives, measured or estimated or computed, for an aircraft in approach phase or in takeoff phase, to determine if the aircraft is or will be put in an anomalous configuration in order to join a stable approach path or takeoff path. A 3 reference value of kinetic energy andor potential energy (or time derivatives thereof) is provided, and a comparison index .for the estimated energy and reference energy is computed and compared with a normal range of index values for a corresponding aircraft maneuver. If the computed energy index lies outside the normal index range, this phase of the aircraft is identified as anomalous, non-normal or potentially unstable.
Thormahlen's test; Melanin - urine ... A clean-catch urine sample is needed. ... this substance that it shows up in the urine. ... Normally, melanin is not present in urine. Normal value ranges may ... measurements or test different samples. Talk to your health ...
McMichael, Lee; Edson, Daniel; McLaughlin, Amanda; Mayer, David; Kopp, Steven; Meers, Joanne; Field, Hume
2015-01-01
This paper establishes reference ranges for hematologic and plasma biochemistry values in wild Black flying-foxes (Pteropus alecto) captured in South East Queensland, Australia. Values were found to be consistent with those of other Pteropus species. Four hundred and forty-seven animals were sampled over 12 months and significant differences were found between age, sex, reproductive and body condition cohorts in the sample population. Mean values for each cohort fell within the determined normal adult reference range, with the exception of elevated levels of alkaline phosphatase in juvenile animals. Hematologic and biochemistry parameters of injured animals showed little or no deviation from the normal reference values for minor injuries, while two animals with more severe injury or abscessation showed leucocytosis, anaemia, thrombocytosis, hyperglobulinemia and hypoalbuminemia. PMID:25938493
Ling, C. R.; Foster, M. A.; Mallard, J. R.
1979-01-01
In separate experiments, normal foreign tissue and malignant tumour were implanted s.c. into the rat thigh. NMR T1 values of the adjacent normal muscle, resulting from local inflammatory reactions or from malignant invasion, were measured. Elevations in T1 of the underlying muscle occurred within 24 h in both experiments, and it is believed these were caused by rapid inflammatory and immunological reactions to the implants. However the T1 values of muscle samples adjacent to the non-malignant implants decreased during the 11 days after implantation, dropping to values within the normal range. In the second experiment there was progressive malignant invasion into the normal adjacent tissue and the elevated T1 values were maintained throughout the 12-day period. The effects of the implantation on tissue water content are discussed in relation to NMR T1 relaxation times, and the relevance to whole-body NMR imaging of elevated T1 values due to nonmalignant pathological states is considered. PMID:526431
Measurements of normal joint angles by goniometry in calves.
Sengöz Şirin, O; Timuçin Celik, M; Ozmen, A; Avki, S
2014-01-01
The aim of this study was to establish normal reference values of the forelimb and hindlimb joint angles in normal Holstein calves. Thirty clinically normal Holstein calves that were free of any detectable musculoskeletal abnormalities were included in the study. A standard transparent plastic goniometer was used to measure maximum flexion, maximum extension, and range-of-motion of the shoulder, elbow, carpal, hip, stifle, and tarsal joints. The goniometric measurements were done on awake calves that were positioned in lateral recumbency. The goniometric values were measured and recorded by two independent investigators. As a result of the study it was concluded that goniometric values obtained from awake calves in lateral recumbency were found to be highly consistent and accurate between investigators (p <0.05). The data of this study acquired objective and useful information on the normal forelimb and hindlimb joint angles in normal Holstein calves. Further studies can be done to predict detailed goniometric values from different diseases and compare them.
Chen, Defu; Ren, Jie; Wang, Ying; Zhao, Hongyou; Li, Buhong; Gu, Ying
2016-03-01
Laser Doppler imaging (LDI) and laser speckle imaging (LSI) are two major optical techniques aiming at non-invasively imaging the skin blood perfusion. However, the relationship between perfusion values determined by LDI and LSI has not been fully explored. 8 healthy volunteers and 13 PWS patients were recruited. The perfusions in normal skin on the forearm of 8 healthy volunteers were simultaneously measured by both LDI and LSI during post-occlusive reactive hyperemia (PORH). Furthermore, the perfusions of port wine stains (PWS) lesions and contralateral normal skin of 10 PWS patients were also determined. In addition, the perfusions for PWS lesions from 3 PWS patients were successively monitored at 0, 10 and 20min during vascular-targeted photodynamic therapy (V-PDT). The average perfusion values determined by LSI were compared with those of LDI for each subject. In the normal skin during PORH, power function provided better fits of perfusion values than linear function: powers for individual subjects go from 1.312 to 1.942 (R(2)=0.8967-0.9951). There was a linear relationship between perfusion values determined by LDI and LSI in PWS and contralateral normal skin (R(2)=0.7308-0.9623), and in PWS during V-PDT (R(2)=0.8037-0.9968). The perfusion values determined by LDI and LSI correlate closely in normal skin and PWS over a broad range of skin perfusion. However, it still suggests that perfusion range and characteristics of the measured skin should be carefully considered if LDI and LSI measures are compared. Copyright © 2015 Elsevier B.V. All rights reserved.
Analysis of VOT in Turkish Speakers with Aphasia
ERIC Educational Resources Information Center
Kopkalli-Yavuz, Handan; Mavis, Ilknur; Akyildiz, Didem
2011-01-01
Studies investigating voicing onset time (VOT) production by speakers with aphasia have shown that nonfluent aphasics show a deficit in the articulatory programming of speech sounds based on the range of VOT values produced by aphasic individuals. If the VOT value lies between the normal range of VOT for the voiced and voiceless categories, then…
Regional ADC values of the normal brain: differences due to age, gender, and laterality.
Naganawa, Shinji; Sato, Kimihide; Katagiri, Toshio; Mimura, Takeo; Ishigaki, Takeo
2003-01-01
The purpose of this study was to evaluate the stability of measurement for apparent diffusion coefficient (ADC) values in normal brain, to clarify the effect of aging on ADC values, to compare ADC values between men and women, and to compare ADC values between right and left sides of the brain. To evaluate the stability of measurements, five normal volunteers (four men and one woman) were examined five times on different days. Then, 294 subjects with normal MR imaging (147 men and 147 women; age range 20-89 years) were measured. The ADC measurement in normal volunteers was stable. The ADC values stayed within the 5% deviation of average values in all volunteers (mean+/-standard deviation 2.3+/-1.2%). The ADC values gradually increased by aging in all regions. In thalamus, no significant difference was seen between right and left in the subjects under 60 years; however, right side showed higher values in the subjects over 60 years (p<0.01). In the subjects under 60 years, women showed higher values in right frontal, bilateral thalamus, and temporal (p<0.01); however, in the subjects over 60 years, no region showed difference between men and women. The knowledge obtained in this study may be helpful to understand the developmental and aging mechanisms of normal brain and may be useful for the future quantitative study as a reference.
Nelson, Winnie W; Wang, Li; Baser, Onur; Damaraju, Chandrasekharrao V; Schein, Jeffrey R
2015-02-01
Although efficacious in stroke prevention in non-valvular atrial fibrillation, many warfarin patients are sub-optimally managed. To evaluate the association of international normalized ratio control and clinical outcomes among new warfarin patients with non-valvular atrial fibrillation. Adult non-valvular atrial fibrillation patients (≥18 years) initiating warfarin treatment were selected from the US Veterans Health Administration dataset between 10/2007 and 9/2012. Valid international normalized ratio values were examined from the warfarin initiation date through the earlier of the first clinical outcome, end of warfarin exposure or death. Each patient contributed multiple in-range and out-of-range time periods. The relative risk ratios of clinical outcomes associated with international normalized ratio control were estimated. 34,346 patients were included for analysis. During the warfarin exposure period, the incidence of events per 100 person-years was highest when patients had international normalized ratio <2:13.66 for acute coronary syndrome; 10.30 for ischemic stroke; 2.93 for transient ischemic attack; 1.81 for systemic embolism; and 4.55 for major bleeding. Poisson regression confirmed that during periods with international normalized ratio <2, patients were at increased risk of developing acute coronary syndrome (relative risk ratio: 7.9; 95 % confidence interval 6.9-9.1), ischemic stroke (relative risk ratio: 7.6; 95 % confidence interval 6.5-8.9), transient ischemic attack (relative risk ratio: 8.2; 95 % confidence interval 6.1-11.2), systemic embolism (relative risk ratio: 6.3; 95 % confidence interval 4.4-8.9) and major bleeding (relative risk ratio: 2.6; 95 % confidence interval 2.2-3.0). During time periods with international normalized ratio >3, patients had significantly increased risk of major bleeding (relative risk ratio: 1.5; 95 % confidence interval 1.2-2.0). In a Veterans Health Administration non-valvular atrial fibrillation population, exposure to out-of-range international normalized ratio values was associated with significantly increased risk of adverse clinical outcomes.
Serum chromium level normally is less than or equal to 1.4 micrograms/milliliter (µg/mL) or 26924.80 nanomoles/L (nmol/L). Normal value ranges may vary slightly among different laboratories. Talk to your provider about the meaning of your specific test result.
Facial-Attractiveness Choices Are Predicted by Divisive Normalization.
Furl, Nicholas
2016-10-01
Do people appear more attractive or less attractive depending on the company they keep? A divisive-normalization account-in which representation of stimulus intensity is normalized (divided) by concurrent stimulus intensities-predicts that choice preferences among options increase with the range of option values. In the first experiment reported here, I manipulated the range of attractiveness of the faces presented on each trial by varying the attractiveness of an undesirable distractor face that was presented simultaneously with two attractive targets, and participants were asked to choose the most attractive face. I used normalization models to predict the context dependence of preferences regarding facial attractiveness. The more unattractive the distractor, the more one of the targets was preferred over the other target, which suggests that divisive normalization (a potential canonical computation in the brain) influences social evaluations. I obtained the same result when I manipulated faces' averageness and participants chose the most average face. This finding suggests that divisive normalization is not restricted to value-based decisions (e.g., attractiveness). This new application to social evaluation of normalization, a classic theory, opens possibilities for predicting social decisions in naturalistic contexts such as advertising or dating.
Halitosis as a product of hepatic disease.
Guglielmi, M; Beushausen, M; Feng, C; Beech, A; Baur, D
2014-09-01
This study evaluated halitosis in patients suffering from hepatic disease. Twenty-five patients (12 males and 13 females) aged between 16 and 73 years who had undergone treatment for liver disease were included in this study. Three halimeter recordings were performed to measure methyl mercarptan and hydrogen sulphite. Mean values were calculated and compared with normal values (75-120 ppb). The level of significance was set at P < .05. Results: Thirteen of the 25 subjects (52%) had normal Volatile Sulphur Compound (VSC) values (75-120 ppb). Twelve subjects (48%) recorded values ranging from 132 to 1112 ppb. There was no correlation between hepatic pathology and halitosis. Fifty-two percent of all subjects had poor oral hygiene, strongly correlated with high VSC values (P<0.05) whereas the remaining 48% with good hygiene had normal levels of VSC. Within the limitations of this study, high values of VSC were not associated with the presence of hepatic disease.
Some blood chemistry values for the juvenile coho salmon (Oncorhynchus kisutch)
Wedemeyer, Gary; Chatterton, K.
1971-01-01
Overlapping Gaussian distribution curves were resolved into normal ranges for 1800 clinical test values obtained from caudal arterial blood or plasma of more than 1000 juvenile coho salmon (Oncorhynchus kisutch) held under defined conditions of diet and temperature. Estimated normal blood chemistry ranges were bicarbonate, 9.5–12.6 mEq/liter; blood urea nitrogen (BUN), 0.9–3.4 mg/100 ml; chloride, 122–136 mEq/liter; cholesterol, 88–262 mg/100 ml;pCO2, 2.6–6.1 mm Hg (10 C); glucose, 41–135 mg/100 ml; hematocrit, 32.5–52.5%; hemoglobin, 6.5–9.9 g/100 ml; total protein, 1.4–4.3 g/100 ml; blood pH (10 C), 7.51–7.83. The calculated range of normal acid–base balance vs. water temperature is also presented.
Papasozomenou, Panayiota; Athanasiadis, Apostolos P; Zafrakas, Menelaos; Panteris, Eleftherios; Loufopoulos, Aristoteles; Assimakopoulos, Efstratios; Tarlatzis, Basil C
2016-03-01
To compare normal ranges of ultrasonographically measured fetal nasal bone length in the second trimester between different ethnic groups. A prospective, non-interventional study in order to establish normal ranges of fetal nasal bone length in the second trimester in a Greek population was conducted in 1220 singleton fetuses between 18 completed weeks and 23 weeks and 6 days of gestation. A literature search followed in order to identify similar studies in different population groups. Fetal nasal bone length mean values and percentiles from different population groups were compared. Analysis of measurements in the Greek population showed a linear association, i.e., increasing nasal bone length with increasing gestational age from 5.73 mm at 18 weeks to 7.63 mm at 23 weeks. Eleven studies establishing normal ranges of fetal nasal bone length in the second trimester were identified. Comparison of fetal nasal bone length mean values between the 12 population groups showed statistically significant differences (P<0.0001). Normal ranges of fetal nasal bone length in the second trimester vary significantly between different ethnic groups. Hence, distinct ethnic nomograms of fetal nasal bone length in the second trimester should be used in a given population rather than an international model.
Yi, Jizheng; Mao, Xia; Chen, Lijiang; Xue, Yuli; Rovetta, Alberto; Caleanu, Catalin-Daniel
2015-01-01
Illumination normalization of face image for face recognition and facial expression recognition is one of the most frequent and difficult problems in image processing. In order to obtain a face image with normal illumination, our method firstly divides the input face image into sixteen local regions and calculates the edge level percentage in each of them. Secondly, three local regions, which meet the requirements of lower complexity and larger average gray value, are selected to calculate the final illuminant direction according to the error function between the measured intensity and the calculated intensity, and the constraint function for an infinite light source model. After knowing the final illuminant direction of the input face image, the Retinex algorithm is improved from two aspects: (1) we optimize the surround function; (2) we intercept the values in both ends of histogram of face image, determine the range of gray levels, and stretch the range of gray levels into the dynamic range of display device. Finally, we achieve illumination normalization and get the final face image. Unlike previous illumination normalization approaches, the method proposed in this paper does not require any training step or any knowledge of 3D face and reflective surface model. The experimental results using extended Yale face database B and CMU-PIE show that our method achieves better normalization effect comparing with the existing techniques.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Reister, D.B.; Unseren, M.A.; Baker, J.E.
We discuss a series of surface following experiments using a range finder mounted on the end of an arm that is mounted on a vehicle. The goal is to keep the range finder at a fixed distance from an unknown surface and to keep the orientation of the range finder perpendicular to the surface. During the experiments, the vehicle moves along a predefined trajectory while planning software determines the position and orientation of the arm. To keep the range finder perpendicular to the surface, the planning software calculates the surface normal for the unknown surface. We assume that the unknownmore » surface is a cylinder (the surface depends on x and y but does not depend on z). To calculate the surface normal, the planning software must calculate the locations (x,y) of points on the surface in world coordinates. The calculation requires data on the position and orientation of the vehicle, the position and orientation of the arm, and the distance from the range finder to the surface. We discuss four series of experiments. During the first series of experiments, the calculated surface normal values had large high frequency random variations. A filter was used to produce an average value for the surface normal and we limited the rate of change in the yaw angle target for the arm. We performed the experiment for a variety of concave and convex surfaces. While the experiments were qualitative successes, the measured distance to the surface was significantly different than the target. The distance errors were systematic, low frequency, and had magnitudes up to 25 mm. During the second series of experiments, we reduced the variations in the calculated surface normal values. While reviewing the data collected while following the surface of a barrel, we found that the radius of the calculated surface was significantly different than the measured radius of the barrel.« less
Economic values under inappropriate normal distribution assumptions.
Sadeghi-Sefidmazgi, A; Nejati-Javaremi, A; Moradi-Shahrbabak, M; Miraei-Ashtiani, S R; Amer, P R
2012-08-01
The objectives of this study were to quantify the errors in economic values (EVs) for traits affected by cost or price thresholds when skewed or kurtotic distributions of varying degree are assumed to be normal and when data with a normal distribution is subject to censoring. EVs were estimated for a continuous trait with dichotomous economic implications because of a price premium or penalty arising from a threshold ranging between -4 and 4 standard deviations from the mean. In order to evaluate the impacts of skewness, positive and negative excess kurtosis, standard skew normal, Pearson and the raised cosine distributions were used, respectively. For the various evaluable levels of skewness and kurtosis, the results showed that EVs can be underestimated or overestimated by more than 100% when price determining thresholds fall within a range from the mean that might be expected in practice. Estimates of EVs were very sensitive to censoring or missing data. In contrast to practical genetic evaluation, economic evaluation is very sensitive to lack of normality and missing data. Although in some special situations, the presence of multiple thresholds may attenuate the combined effect of errors at each threshold point, in practical situations there is a tendency for a few key thresholds to dominate the EV, and there are many situations where errors could be compounded across multiple thresholds. In the development of breeding objectives for non-normal continuous traits influenced by value thresholds, it is necessary to select a transformation that will resolve problems of non-normality or consider alternative methods that are less sensitive to non-normality.
Comparison of two immunoradiometric assays for serum thyrotropin
DOE Office of Scientific and Technical Information (OSTI.GOV)
Scheinin, B.; Drew, H.; La France, N.
1985-05-01
An ultra-sensitive TSH assay capable of detecting subnormal TSH levels would be useful in confirming suppressed pituitary function as seen in hyperthyroidism. Two sensitive immunoradiometric TSH assays (IRMA's) were studied to determine how well they distinguished thyrotoxic patients from normal subjects. Serono Diagnostics' method employs three monoclonal antibodies specific for different regions of the TSH molecule with a minimum detectable dose (MDD) limit of 0.1 ..mu..IU/ml. Precision studies using a low TSH control in the 1.8 ..mu..IU/ml range gave CV's of 15.0%. Boots-Celltech Diagnostics method is a two site IRMA using two monoclonal antibodies. The MDD limit is 0.05 ..mu..IU/mlmore » with precision CV's of 29.3% at a TSH control range of 0.62 ..mu..IU/ml. In 24 chemically thyrotoxic patients, the mean serum TSH concentration was significantly lower than in the normal control subjects: for Serono, 0.19 ..mu..IU/ml vs. 2.34 ..mu..IU/ml and for Boots Celltech, 0.18 IU/ml vs 2.06 ..mu..IU/ml. The range of TSH was 0 to 0.5 ..mu..IU/ml in thyrotoxic patients using Serono with the exception of one patient having a TSH value of 0.8 ..mu..IU/ml. The normal range was 0.6 to 6.0 ..mu..IU/ml. For Boots Celltech the thyrotoxic range was 0 to 0.2 ..mu..IU/ml with that same thyrotoxic patient giving a TSH value of 0.7 ..mu..IU/ml with a normal range of 0.6 to 5.0 IU/ml. Serum TSH measurements using both procedures are highly sensitive for distinguishing thyrotoxic patients from normal subjects and are useful to confirm suppressed pituitary function.« less
Yiming, Gulinuer; Zhou, Xianhui; Lv, Wenkui; Peng, Yi; Zhang, Wenhui; Cheng, Xinchun; Li, Yaodong; Xing, Qiang; Zhang, Jianghua; Zhou, Qina; Zhang, Ling; Lu, Yanmei; Wang, Hongli; Tang, Baopeng
2017-01-01
Brachial-ankle pulse wave velocity (baPWV), a direct measure of aortic stiffness, has increasingly become an important assessment for cardiovascular risk. The present study established the reference and normal values of baPWV in a Central Asia population in Xinjiang, China. We recruited participants from a central Asia population in Xinjiang, China. We performed multiple regression analysis to investigate the determinants of baPWV. The median and 10th-90th percentiles were calculated to establish the reference and normal values based on these categories. In total, 5,757 Han participants aged 15-88 years were included in the present study. Spearman correlation analysis showed that age (r = 0.587, p < 0.001) and mean blood pressure (MBP, r = 0.599, p <0.001) were the major factors influencing the values of baPWV in the reference population. Furthermore, in the multiple linear regression analysis, the standardized regression coefficients of age (0.445) and MBP (0.460) were much higher than those of body mass index, triglyceride, and glycemia (-0.054, 0.035, and 0.033, respectively). In the covariance analysis, after adjustment for age and MBP, only diabetes was the significant independent determinant of baPWV (p = 0.009). Thus, participants with diabetes were excluded from the reference value population. The reference values ranged from 14.3 to 25.2 m/s, and the normal values ranged from 13.9 to 21.2 m/s. This is the first study that has established the reference and normal values for baPWV according to age and blood pressure in a Central Asia population.
Economic Valuation Tools and their Applications to Ecosystem Services
Many of the ecosystem services that people value are not normally bought and sold; yet, this does not mean they have no measurable economic value. Economists have developed a set of approaches and tools for valuing the full range of both market and “non-market” ecosystem goods an...
A Dog with Pseudo-Addison Disease Associated with Trichuris vulpis Infection.
Venco, Luigi; Valenti, Valentina; Genchi, Marco; Grandi, Giulio
2011-01-01
A female Rottweiler dog was presented with a history of intermittent vomiting and diarrhoea, dysorexia, weakness, and weight loss. Haemocytometry and biochemistry values were within normal ranges except for electrolyte analyses, that demonstrated hyponatremia and hyperkalemia with a decreased sodium/potassium ratio. A diagnosis of hypoadrenocorticism was suspected. Basal and post-ACTH stimulation cortisolemia were within the normal values. Electrocardiography was normal, and thoracic radiography showed no significant modifications. On abdominal ultrasonography, adrenal glands appeared normal, while the bowel was distended, and several thin linear hyperechoic objects floating in the lumen were observed. Two adult female whipworms (Trichuris vulpis) were collected following bowel irrigation. Anthelmintic treatment against the parasite was curative.
Colodro, Juan Fernando Mata; Berná, Alfredo Serna; Puchades, Vicente Puchades; Amores, David Ramos; Baños, Miguel Alcaraz
2017-01-01
The aim of this work is to verify the use of radiochromic film in the quality assurance (QA) of volumetric-modulated arc therapy (VMAT) lung stereotactic body radiation therapy (SBRT) plans and compare the results with those obtained using an ion chamber array. QA was performed for 14 plans using a two-dimensional-array seven29 and EBT3 film. Dose values per session ranged between 7.5 Gy and 18 Gy. The multichannel method was used to obtain a dose map for film. The results obtained were compared with treatment planning system calculated profiles through gamma analysis. Passing criteria were 3%/3 mm, 2%/2 mm and 3%/1.5 mm with maximum and local dose (LD) normalization. Mean gamma passing rate (GPR) (percentage of points presenting a gamma function value of <1) was obtained and compared. Calibration curves were obtained for each color channel within the dose range 0-16 Gy. Mean GPR values for film were >98.9% for all criteria when normalizing per maximum dose. When using LD, normalization was >92.7%. GPR values for the array were lower for all criteria; this difference being statistically significant when normalizing at LD, reaching 12% for the 3%/1.5 mm criterion. Both detectors provide satisfactory results for the QA of plans for VMAT lung SBRT. The film provided greater mean GPR values, afforded greater spatial resolution and was more efficient overall.
Colodro, Juan Fernando Mata; Berná, Alfredo Serna; Puchades, Vicente Puchades; Amores, David Ramos; Baños, Miguel Alcaraz
2017-01-01
Introduction: The aim of this work is to verify the use of radiochromic film in the quality assurance (QA) of volumetric-modulated arc therapy (VMAT) lung stereotactic body radiation therapy (SBRT) plans and compare the results with those obtained using an ion chamber array. Materials and Methods: QA was performed for 14 plans using a two-dimensional-array seven29 and EBT3 film. Dose values per session ranged between 7.5 Gy and 18 Gy. The multichannel method was used to obtain a dose map for film. Results: The results obtained were compared with treatment planning system calculated profiles through gamma analysis. Passing criteria were 3%/3 mm, 2%/2 mm and 3%/1.5 mm with maximum and local dose (LD) normalization. Mean gamma passing rate (GPR) (percentage of points presenting a gamma function value of <1) was obtained and compared. Calibration curves were obtained for each color channel within the dose range 0–16 Gy. Mean GPR values for film were >98.9% for all criteria when normalizing per maximum dose. When using LD, normalization was >92.7%. GPR values for the array were lower for all criteria; this difference being statistically significant when normalizing at LD, reaching 12% for the 3%/1.5 mm criterion. Conclusion: Both detectors provide satisfactory results for the QA of plans for VMAT lung SBRT. The film provided greater mean GPR values, afforded greater spatial resolution and was more efficient overall. PMID:28974858
Prasad, Vikas; Steffen, Ingo G; Diederichs, Gerd; Makowski, Marcus R; Wust, Peter; Brenner, Winfried
2016-06-01
The aim of this study was to determine the physiological and pathophysiological biodistribution of [(68)Ga]PSMA-HBED-CC (PSMA-11) ([(68)Ga]PSMA) in patients with prostate cancer (PCA) to establish the range of normal uptake in relevant organs and primary prostate tumours, locally recurrent PCA, lymph and bone metastases and other metastatic lesions. Additionally, we aimed to determine a cut-off uptake value for differentiation of primary tumours from normal prostate tissue. Overall, [(68)Ga]PSMA positron emission tomography/x-ray computed tomography (PET/CT) of 101 patients (mean age 69.1 years) with PCA was analysed retrospectively. For assessment of tracer biodistribution, maximum standardized uptake values (SUVmax) were calculated for various normal organs, as well as for primary tumours (PT) and/or metastases. Results are presented as median, interquartile range (IQR; 25th quantil-75th quantil) and range (minimum-maximum). [(68)Ga]PSMA PET/CT was performed 50 min (range 30-126) after injection of 109 MBq (range 84-158). Regarding biodistribution, highest uptake (median/IQR/range) of the tracer was found in the kidneys (49.6/40.7-57.6/2.7-97.0) followed by the submandibular glands (17.3/13.7-21.2/7.5-30.4), parotid glands (16.1/12.2-19.8/5.5-30.9) and duodenum (13.8/10.5-17.2/5.8-26.9). The best cut-off value for differentiating physiological uptake in the primary tumour from that in the prostate was found to be an SUVmax of 3.2. The median SUVmax in the PT (n = 35), locally recurrent PCA (n = 8), lymph node (n = 166), bone (n = 157) and other metastases (n = 3) were 10.2, 5.9, 6.2, 7.4 and 3.8, respectively. The best cut-off values for differentiating non-pathological uptake in lymph nodes and bones from tumour uptake were found to be SUVmax of 3.2 and 1.9, respectively. Patients with PSA <2 had significantly lower SUVmax in bone metastases as compared to patients with PSA ≥2 (p < 0.01). This biodistribution study provided a broad range of uptake data of [(68)Ga]PSMA-11 for normal organs/tissues, primary prostate tumours and metastatic lesions based on a large patient cohort. Both PT and small metastatic lesions were detectable due to their high tracer uptake. Four-times-higher median uptake in PT in comparison to normal prostate stroma resulted in a high diagnostic accuracy that could potentially be used for multimodal image-guided biopsy with dedicated reconstruction software.
Transmission of isotropic light across a dielectric surface in two and three dimensions.
NASA Technical Reports Server (NTRS)
Allen, W. A.
1973-01-01
Average transmittance of polarized diffuse light across a dielectric surface is calculated in both two and three dimensions. The incident light in both cases is confined to an angular range measured from the surface normal. Limiting values in three dimensions correspond to known results for two cases, (1) normal incidence, and (2) diffuse light incident from a 180 deg cone. The two-dimensional formulation is solvable in terms of elliptic functions and incomplete elliptic integrals of the first, second, and third kinds. Results are displayed graphically for values of transmittances in excess of 0.9 associated with relative indices of refraction in the range m = 1.0 to m = 2.6.
Kaitaniemi, Pekka
2008-04-09
Allometric equations are widely used in many branches of biological science. The potential information content of the normalization constant b in allometric equations of the form Y = bX(a) has, however, remained largely neglected. To demonstrate the potential for utilizing this information, I generated a large number of artificial datasets that resembled those that are frequently encountered in biological studies, i.e., relatively small samples including measurement error or uncontrolled variation. The value of X was allowed to vary randomly within the limits describing different data ranges, and a was set to a fixed theoretical value. The constant b was set to a range of values describing the effect of a continuous environmental variable. In addition, a normally distributed random error was added to the values of both X and Y. Two different approaches were then used to model the data. The traditional approach estimated both a and b using a regression model, whereas an alternative approach set the exponent a at its theoretical value and only estimated the value of b. Both approaches produced virtually the same model fit with less than 0.3% difference in the coefficient of determination. Only the alternative approach was able to precisely reproduce the effect of the environmental variable, which was largely lost among noise variation when using the traditional approach. The results show how the value of b can be used as a source of valuable biological information if an appropriate regression model is selected.
Wålinder, Olov
The symptoms of primary adrenocortical insufficiency (Addison's disease) such as fatigue, anorexia, hypotension and hyperpigmentation are similar to those of normal pregnancy. Addison's disease is rare and the diagnosis can easily be overlooked during pregnancy. The concentration of corticosteroid-binding globulin (CBG) and cortisol in serum as well as urinary free cortisol increase 2-3 times during pregnancy. Therefore, the reference ranges for nonpregnant persons cannot be used during pregnancy. The diagnosis of Addison's disease in pregnancy should be based on analysis of p-ACTH which remains within the reference range in normal pregnancy until delivery. A case of Addison's disease diagnosed during pregnancy is presented and it illustrates the diagnostic difficulties. In patients taking oral estrogen containing contraceptives, serum levels of CBG and cortisol also increase 2-3 times, making s-cortisol values difficult to interpret. Also in these patients, analysis of p-ACTH is of value when suspecting Addison's disease.
McGhie, Jackie S; Menting, Myrthe E; Vletter, Wim B; Frowijn, René; Roos-Hesselink, Jolien W; van der Zwaan, Heleen B; Soliman, Osama I I; Geleijnse, Marcel L; van den Bosch, Annemien E
2017-07-01
The aim of this prospective study was to evaluate the feasibility and establish normal values of functional right ventricle (RV) parameters as assessed in our four, long-axis view RV model using iRotate echocardiography. Furthermore, we evaluated the potential use of this model in patients with abnormally loaded RVs. One hundred and fifty-five healthy subjects aged 20-72 years (≥28 subjects per decile) were prospectively recruited. We used non-dedicated RV speckle-tracking software to test the feasibility and to establish normal range values of peak systolic global longitudinal RV strain (RV-GLS) from the RV free-walls (septum was excluded). Also normal range values for: dimensions, tricuspid annular plane systolic excursion (TAPSE) and tricuspid annular peak systolic velocity (TDI-S') were established. The feasibility of RV-GLS was 88, 84, and 62%, respectively, in the lateral, inferior, and anterior free wall. Mean RV-GLS normal values were -24.5 ± 4.9% for lateral wall and -25.4 ± 5.0% for anterior wall. Mean RV-GLS in the inferior wall was -23.2 ± 4.4% in the aortic (Ao) view and -20.7 ± 5.0% in the coronal (CV) view. The feasibility of mean RV-GLS was 100% in the anterior, lateral, and inferior walls in abnormally dilated RVs. The feasibility of all RV parameters assessed in the four-view iRotate model is good to excellent. Normal values for RV dimension and function of the anterior, inferior, and lateral RV walls have been established. Further studies and dedicated RV speckle-tracking software are warranted to discover the full potential of this new technique. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions, please email: journals.permissions@oup.com.
Frequency-dependent complex modulus of the uterus: preliminary results
NASA Astrophysics Data System (ADS)
Kiss, Miklos Z.; Hobson, Maritza A.; Varghese, Tomy; Harter, Josephine; Kliewer, Mark A.; Hartenbach, Ellen M.; Zagzebski, James A.
2006-08-01
The frequency-dependent complex moduli of human uterine tissue have been characterized. Quantification of the modulus is required for developing uterine ultrasound elastography as a viable imaging modality for diagnosing and monitoring causes for abnormal uterine bleeding and enlargement, as well assessing the integrity of uterine and cervical tissue. The complex modulus was measured in samples from hysterectomies of 24 patients ranging in age from 31 to 79 years. Measurements were done under small compressions of either 1 or 2%, at low pre-compression values (either 1 or 2%), and over a frequency range of 0.1-100 Hz. Modulus values of cervical tissue monotonically increased from approximately 30-90 kPa over the frequency range. Normal uterine tissue possessed modulus values over the same range, while leiomyomas, or uterine fibroids, exhibited values ranging from approximately 60-220 kPa.
Critical laboratory values in hemostasis: toward consensus.
Lippi, Giuseppe; Adcock, Dorothy; Simundic, Ana-Maria; Tripodi, Armando; Favaloro, Emmanuel J
2017-09-01
The term "critical values" can be defined to entail laboratory test results that significantly lie outside the normal (reference) range and necessitate immediate reporting to safeguard patient health, as well as those displaying a highly and clinically significant variation compared to previous data. The identification and effective communication of "highly pathological" values has engaged the minds of many clinicians, health care and laboratory professionals for decades, since these activities are vital to good laboratory practice. This is especially true in hemostasis, where a timely and efficient communication of critical values strongly impacts patient management. Due to the heterogeneity of available data, this paper is hence aimed to analyze the state of the art and provide an expert opinion about the parameters, measurement units and alert limits pertaining to critical values in hemostasis, thus providing a basic document for future consultation that assists laboratory professionals and clinicians alike. KEY MESSAGES Critical values are laboratory test results significantly lying outside the normal (reference) range and necessitating immediate reporting to safeguard patient health. A broad heterogeneity exists about critical values in hemostasis worldwide. We provide here an expert opinion about the parameters, measurement units and alert limits pertaining to critical values in hemostasis.
SU-F-T-130: [18F]-FDG Uptake Dose Response in Lung Correlates Linearly with Proton Therapy Dose
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, D; Titt, U; Mirkovic, D
2016-06-15
Purpose: Analysis of clinical outcomes in lung cancer patients treated with protons using 18F-FDG uptake in lung as a measure of dose response. Methods: A test case lung cancer patient was selected in an unbiased way. The test patient’s treatment planning and post treatment positron emission tomography (PET) were collected from picture archiving and communication system at the UT M.D. Anderson Cancer Center. Average computerized tomography scan was registered with post PET/CT through both rigid and deformable registrations for selected region of interest (ROI) via VelocityAI imaging informatics software. For the voxels in the ROI, a system that extracts themore » Standard Uptake Value (SUV) from PET was developed, and the corresponding relative biological effectiveness (RBE) weighted (both variable and constant) dose was computed using the Monte Carlo (MC) methods. The treatment planning system (TPS) dose was also obtained. Using histogram analysis, the voxel average normalized SUV vs. 3 different doses was obtained and linear regression fit was performed. Results: From the registration process, there were some regions that showed significant artifacts near the diaphragm and heart region, which yielded poor r-squared values when the linear regression fit was performed on normalized SUV vs. dose. Excluding these values, TPS fit yielded mean r-squared value of 0.79 (range 0.61–0.95), constant RBE fit yielded 0.79 (range 0.52–0.94), and variable RBE fit yielded 0.80 (range 0.52–0.94). Conclusion: A system that extracts SUV from PET to correlate between normalized SUV and various dose calculations was developed. A linear relation between normalized SUV and all three different doses was found.« less
In Vitro Study of Flow Regulation for Pulmonary Insufficiency
Camp, T. A.; Stewart, K. C.; Figliola, R. S.; McQuinn, T.
2007-01-01
Given the tolerance of the right heart circulation to mild regurgitation and gradient, we study the potential of using motionless devices to regulate the pulmonary circulation. In addition, we document the flow performance of two mechanical valves. A motionless diode, a nozzle, a mechanical bileaflet valve, and a tilting disk valve were tested in a pulmonary mock circulatory system over the normal human range of pulmonary vascular resistance (PVR). For the mechanical valves, regurgitant fractions (RFs) and transvalvular pressure gradients were found to be weak functions of PVR. On the low end of normal PVR, the bileaflet and tilting disk valves fluttered and would not fully close. Despite this anomaly, the regurgitant fraction of either valve did not change significantly. The values for RF and transvalvular gradient measured varied from 4 to 7% and 4 to 7 mm Hg, respectively, at 5 lpm for all tests. The diode valve was able to regulate flow with mild regurgitant fraction and trivial gradient but with values higher than either mechanical valve tested. Regurgitant fraction ranged from 2 to 17% in tests extending from PVR values of 1 to 4.5 mm Hg/lpm at 5 lpm and with concomitant increases in gradient up to 17 mm Hg. The regurgitant fraction for the nozzle increased from 2 to 23% over the range of PVR with gradients increasing to 18 mm Hg. The significant findings were: (1) the mechanical valves controlled regurgitation at normal physiological cardiac output and PVR even though they failed to close at some normal values of PVR and showed leaflet flutter; and (2) it may be possible to regulate the pulmonary circulation to tolerable levels using a motionless pulmonary valve device. PMID:17408334
Industrial process surveillance system
Gross, Kenneth C.; Wegerich, Stephan W.; Singer, Ralph M.; Mott, Jack E.
1998-01-01
A system and method for monitoring an industrial process and/or industrial data source. The system includes generating time varying data from industrial data sources, processing the data to obtain time correlation of the data, determining the range of data, determining learned states of normal operation and using these states to generate expected values, comparing the expected values to current actual values to identify a current state of the process closest to a learned, normal state; generating a set of modeled data, and processing the modeled data to identify a data pattern and generating an alarm upon detecting a deviation from normalcy.
Industrial process surveillance system
Gross, K.C.; Wegerich, S.W.; Singer, R.M.; Mott, J.E.
1998-06-09
A system and method are disclosed for monitoring an industrial process and/or industrial data source. The system includes generating time varying data from industrial data sources, processing the data to obtain time correlation of the data, determining the range of data, determining learned states of normal operation and using these states to generate expected values, comparing the expected values to current actual values to identify a current state of the process closest to a learned, normal state; generating a set of modeled data, and processing the modeled data to identify a data pattern and generating an alarm upon detecting a deviation from normalcy. 96 figs.
Industrial Process Surveillance System
Gross, Kenneth C.; Wegerich, Stephan W; Singer, Ralph M.; Mott, Jack E.
2001-01-30
A system and method for monitoring an industrial process and/or industrial data source. The system includes generating time varying data from industrial data sources, processing the data to obtain time correlation of the data, determining the range of data, determining learned states of normal operation and using these states to generate expected values, comparing the expected values to current actual values to identify a current state of the process closest to a learned, normal state; generating a set of modeled data, and processing the modeled data to identify a data pattern and generating an alarm upon detecting a deviation from normalcy.
Electron impact cross sections for the 2,2P state excitation of lithium
NASA Technical Reports Server (NTRS)
Vuskovic, L.; Trajmar, S.; Register, D. F.
1982-01-01
Electron impact excitation of the 2p 2P state of Li was studied at 10, 20, 60, 100, 150 and 200 eV. Relative differential cross sections in the angular range 3-120 deg were measured and then normalized to the absolute scale by using the optical f value. Integral and momentum transfer cross sections were obtained by extrapolating the differential cross sections to 0 deg and to 180 deg. The question of normalizing electron-metal-atom collision cross sections in general was examined and the method of normalization to optical f values in particular was investigated in detail. It has been concluded that the extrapolation of the apparent generalized oscillator strength (obtained from the measured differential cross sections) to the zero momentum transfer limit with an expression using even powers of the momentum transfer and normalization of the limit to the optical f value yields reliable absolute cross sections.
Frayon, Stéphane; Cavaloc, Yolande; Wattelez, Guillaume; Cherrier, Sophie; Lerrant, Yannick; Ashwell, Margaret; Galy, Olivier
2017-12-15
Waist-to-height ratio (WHtR) is a simple anthropometric proxy for central body fat; it is easy to use from a health education perspective. A WHtR value >0.5 has been proposed as a first level indicator of health risk. The first aim of this study was to compare WHtR with values based on body mass index (BMI) in their prediction of the percentage of body fat (%BF) in a multi-ethnic population of adolescents from New-Caledonia (age 11-16year). Secondly, to see whether WHtR >0.5 could be used to detect overfat subjects whose BMI was in the normal range. Body fat percentage (%BF, based on skinfold measurements), BMI and WHtR were calculated for New Caledonian adolescents from different ethnic backgrounds. The relationship between %BF, BMI and WHtR was determined using quadratic models and from linear regression equations. The sensitivity and specificity of WHtR for detecting overfat adolescents (%BF >25% in boys and >30% in girls) were assessed and compared with those from the BMI-based classification. WHtR showed better correlation with %BF than BMI-based measurements. WHtR >0.5 was also more accurate than BMI in detecting overfat adolescents. Moreover, using this boundary value, 8% of adolescents in the normal BMI range were shown to be over-fat. WHtR is a good anthropometric proxy to detect overfat adolescents. Detecting overfat adolescents within the normal BMI range is particularly important for preventing non communicable diseases. We therefore recommend using WHtR for health education programs in the Pacific area and more generally. Copyright © 2017 Asia Oceania Association for the Study of Obesity. Published by Elsevier Ltd. All rights reserved.
Boari, A; Barreca, A; Bestetti, G E; Minuto, F; Venturoli, M
1995-06-01
A 12-year-old mixed-breed male dog was referred to the Clinica Medica Veterinaria of Bologna University for recurrent episodes of seizures due to hypoglycemia with abnormally low plasma insulin levels (18 pmol/l). Resection of a large leiomyoma (780 g) of the gastric wall resulted in a permanent resolution of the hypoglycemic episodes. Insulin-like growth factors I and II (IGF-I and -II) were measured by RIA in serum before and after surgery and in tumor tissue. Results were compared to the serum concentration of 54 normal and to the tissue concentration observed in eight non-hypoglycemic dog gastric wall extracts. Before surgery, circulating immunoreactive IGF-I was 0.92 nmol/l, which is significantly lower than the control values (16.92 +/- 8.44 nmol/l, range 3.53-35.03), while IGF-II was 152 nmol/l, which is significantly higher than the control values (42.21 +/- 3.75, range 31.99-50.74). After surgery, IGF-I increased to 6.80 nmol/l while IGF-II decreased to 45.52 nmol/l. Tumor tissue IGF-II concentration was higher than normal (5.66 nmol/kg tissue as compared to a range in normal gastric wall tissue of 1.14-3.72 nmol/kg), while IGF-I was 0.08 nmol/kg tissue, which is close to the lowest normal value (range in controls, 0.08-1.18 nmol/kg). Partial characterization of IGF-II immunoreactivity extracted from tissue evidenced a molecular weight similar to that of mature IGF-II, thus excluding that peptide released by the tumor is a precursor molecule.(ABSTRACT TRUNCATED AT 250 WORDS)
Measurement of body fat and hydration of the fat-free body in health and disease
DOE Office of Scientific and Technical Information (OSTI.GOV)
Streat, S.J.; Beddoe, A.H.; Hill, G.L.
1985-06-01
Body fat mass, fat-free body mass and body water are basic components of body composition which are used in nutritional and metabolic studies and in patient care. A method of measuring total body fat (TBF), fat-free mass (FFM) and its hydration (TBW/FFM) involving prompt gamma in vivo neutron activation analysis (IVNAA) and tritium dilution has been compared with the more traditional methods of densitometry and skinfold anthropometry in 36 normal volunteers, and with skinfold anthropometry in 56 patients presenting for nutritional support. While the mean values of TBF were in reasonable agreement for the three methods in normals it wasmore » founds that skinfold anthropometry underestimated TBF relative to the IVNAA/tritium method by, on average, 3.0 kg (19%) in patients. Furthermore, the ranges of values in normals of the ratio TBW/FFM for the anthropometric (0.62 to 0.80) and densitometric (0.65 to 0.80) methods were much wider than the range for the IVNAA/tritium method (0.69 to 0.76), in which TBW was measured by tritium dilution in all cases. In the patients, the ranges of this ratio were 0.52 to 0.90 for the anthropometric method and 0.67 to 0.82 for the IVNAA/tritium method; clearly anthropometry yields values of TBW/FFM which are outside accepted biological limits. On the basis of these findings, ranges of TBW/FFM are suggested for both normal adults (0.69 to 0.75) and patients requiring nutritional support (0.67 to 0.83). Finally it is concluded that the IVNAA/tritium method is a suitable method for measuring TBF and FFM and particularly so when body composition is abnormal.« less
Smith, G B; Isaacs, R; Andrews, L; Wee, M Y K; van Teijlingen, E; Bick, D E; Hundley, V
2017-05-01
Obstetric early warning systems are recommended for monitoring hospitalised pregnant and postnatal women. We decided to compare: (i) vital sign values used to define physiological normality; (ii) symptoms and signs used to escalate care; (iii) type of chart used; and (iv) presence of explicit instructions for escalating care. One-hundred-and-twenty obstetric early warning charts and escalation protocols were obtained from consultant-led maternity units in the UK and Channel Islands. These data were extracted: values used to determine normality for each maternal vital sign; chart colour-coding; instructions following early warning system triggering; other criteria used as triggers. There was considerable variation in the charts, warning systems and escalation protocols. Of 120 charts, 89.2% used colour; 69.2% used colour-coded escalation systems. Forty-one (34.2%) systems required the calculation of weighted scores. Seventy-five discrete combinations of 'normal' vital sign ranges were found, the most common being: heart rate=50-99beats/min; respiratory rate=11-20breaths/min; blood pressure, systolic=100-149mmHg, diastolic ≤89mmHg; SpO 2 =95-100%; temperature=36.0-37.9°C; and Alert-Voice-Pain-Unresponsive assessment=Alert. Most charts (90.8%) provided instructions about who to contact following triggering, but only 41.7% gave instructions about subsequent observation frequency. The wide range of 'normal' vital sign values in different systems suggests a lack of equity in the processes for detecting deterioration and escalating care in hospitalised pregnant and postnatal women. Agreement regarding 'normal' vital sign ranges is urgently required and would assist the development of a standardised obstetric early warning system and chart. Copyright © 2017 Elsevier Ltd. All rights reserved.
Swenson, Carolyn W; Smith, Tovia M; Luo, Jiajia; Kolenic, Giselle E; Ashton-Miller, James A; DeLancey, John O
2017-02-01
It is unknown how initial cervix location and cervical support resistance to traction, which we term "apical support stiffness," compare in women with different patterns of pelvic organ support. Defining a normal range of apical support stiffness is important to better understand the pathophysiology of apical support loss. The aims of our study were to determine whether: (1) women with normal apical support on clinic Pelvic Organ Prolapse Quantification, but with vaginal wall prolapse (cystocele and/or rectocele), have the same intraoperative cervix location and apical support stiffness as women with normal pelvic support; and (2) all women with apical prolapse have abnormal intraoperative cervix location and apical support stiffness. A third objective was to identify clinical and biomechanical factors independently associated with clinic Pelvic Organ Prolapse Quantification point C. We conducted an observational study of women with a full spectrum of pelvic organ support scheduled to undergo gynecologic surgery. All women underwent a preoperative clinic examination, including Pelvic Organ Prolapse Quantification. Cervix starting location and the resistance (stiffness) of its supports to being moved steadily in the direction of a traction force that increased from 0-18 N was measured intraoperatively using a computer-controlled servoactuator device. Women were divided into 3 groups for analysis according to their pelvic support as classified using the clinic Pelvic Organ Prolapse Quantification: (1) "normal/normal" was women with normal apical (C < -5 cm) and vaginal (Ba and Bp < 0 cm) support; (2) normal/prolapse had normal apical support (C < -5 cm) but prolapse of the anterior or posterior vaginal walls (Ba and/or Bp ≥ 0 cm); and (3) prolapse/prolapse had both apical and vaginal wall prolapse (C > -5 cm and Ba and/or Bp ≥ 0 cm). Demographics, intraoperative cervix locations, and apical support stiffness values were then compared. Normal range of cervix location during clinic examination and operative testing was defined by the total range of values observed in the normal/normal group. The proportion of women in each group with cervix locations within and outside the normal range was determined. Linear regression was performed to identify variables independently associated with clinic Pelvic Organ Prolapse Quantification point C. In all, 52 women were included: 14 in the normal/normal group, 11 in the normal/prolapse group, and 27 in the prolapse/prolapse group. At 1 N of traction force in the operating room, 50% of women in the normal/prolapse group had cervix locations outside the normal range while 10% had apical support stiffness outside the normal range. Of women in the prolapse/prolapse group, 81% had cervix locations outside the normal range and 8% had apical support stiffness outside the normal range. Similar results for cervix locations were observed at 18 N of traction force; however the proportion of women with apical support stiffness outside the normal range increased to 50% in the normal/prolapse group and 59% in the prolapse/prolapse group. The prolapse/prolapse group had statistically lower apical support stiffness compared to the normal/normal group with increased traction from 1-18 N (0.47 ± 0.18 N/mm vs 0.63 ± 0.20 N/mm, P = .006), but all other comparisons were nonsignificant. After controlling for age, parity, body mass index, and apical support stiffness, cervix location at 1 N traction force remained an independent predictor of clinic Pelvic Organ Prolapse Quantification point C, but only in the prolapse/prolapse group. Approximately 50% of women with cystocele and/or rectocele but normal apical support in the clinic had cervix locations outside the normal range under intraoperative traction, while 19% of women with uterine prolapse had normal apical support. Identifying women whose apical support falls outside a defined normal range may be a more accurate way to identify those who truly need a hysterectomy and/or an apical support procedure and to spare those who do not. Copyright © 2016 Elsevier Inc. All rights reserved.
... common measurements for results of these tests. Normal value ranges may vary slightly among different laboratories. Some labs use different measurements or test different samples. Talk to your health ...
Informative graphing of continuous safety variables relative to normal reference limits.
Breder, Christopher D
2018-05-16
Interpreting graphs of continuous safety variables can be complicated because differences in age, gender, and testing site methodologies data may give rise to multiple reference limits. Furthermore, data below the lower limit of normal are compressed relative to those points above the upper limit of normal. The objective of this study is to develop a graphing technique that addresses these issues and is visually intuitive. A mock dataset with multiple reference ranges is initially used to develop the graphing technique. Formulas are developed for conditions where data are above the upper limit of normal, normal, below the lower limit of normal, and below the lower limit of normal when the data value equals zero. After the formulae are developed, an anonymized dataset from an actual set of trials for an approved drug is evaluated comparing the technique developed in this study to standard graphical methods. Formulas are derived for the novel graphing method based on multiples of the normal limits. The formula for values scaled between the upper and lower limits of normal is a novel application of a readily available scaling formula. The formula for the lower limit of normal is novel and addresses the issue of this value potentially being indeterminate when the result to be scaled as a multiple is zero. The formulae and graphing method described in this study provides a visually intuitive method to graph continuous safety data including laboratory values, vital sign data.
Hip strength and range of motion: Normal values from a professional football league.
Mosler, Andrea B; Crossley, Kay M; Thorborg, Kristian; Whiteley, Rod J; Weir, Adam; Serner, Andreas; Hölmich, Per
2017-04-01
To determine the normal profiles for hip strength and range of motion (ROM) in a professional football league in Qatar, and examine the effect of leg dominance, age, past history of injury, and ethnicity on these profiles. Cross-sectional cohort study. Participants included 394 asymptomatic, male professional football players, aged 18-40 years. Strength was measured using a hand held dynamometer with an eccentric test in side-lying for hip adduction and abduction, and the squeeze test in supine with 45° hip flexion. Range of motion measures included: hip internal and external rotation in 90° flexion, hip IR in prone, bent knee fall out and hip abduction in side-lying. Demographic information was collected and the effect on the profiles was analysed using linear mixed models with repeated measures. Strength values (mean±SD) were: adduction=3.0±0.6Nm/kg, abduction=2.6±0.4Nm/kg, adduction/abduction ratio=1.2±0.2, Squeeze test=3.6±0.8N/kg. Range of motion values: internal rotation in flexion=32±8°, external rotation=38±8°, internal rotation in prone=38±8°, bent knee fall out=13±4.4cm, abduction in side-lying=50±7.3°. Leg dominance had no clinically relevant effect on these profiles. Multivariate analysis demonstrated that age had a minor influence on squeeze strength (-0.03N/kg/year), external rotation (-0.30°/year) and abduction range (-0.19°/year) but past history of injury, and ethnicity did not. Normal values are documented for hip strength and range of motion that can be used as reference profiles in the clinical assessment, screening, and management of professional football players. Leg dominance, recent past injury history and ethnicity do not need to be accounted for when using these profiles for comparison purposes. Copyright © 2016 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.
Travison, Thomas G.; Vesper, Hubert W.; Orwoll, Eric; Wu, Frederick; Kaufman, Jean Marc; Wang, Ying; Lapauw, Bruno; Fiers, Tom; Matsumoto, Alvin M.
2017-01-01
Background: Reference ranges for testosterone are essential for making a diagnosis of hypogonadism in men. Objective: To establish harmonized reference ranges for total testosterone in men that can be applied across laboratories by cross-calibrating assays to a reference method and standard. Population: The 9054 community-dwelling men in cohort studies in the United States and Europe: Framingham Heart Study; European Male Aging Study; Osteoporotic Fractures in Men Study; and Male Sibling Study of Osteoporosis. Methods: Testosterone concentrations in 100 participants in each of the four cohorts were measured using a reference method at Centers for Disease Control and Prevention (CDC). Generalized additive models and Bland-Altman analyses supported the use of normalizing equations for transformation between cohort-specific and CDC values. Normalizing equations, generated using Passing-Bablok regression, were used to generate harmonized values, which were used to derive standardized, age-specific reference ranges. Results: Harmonization procedure reduced intercohort variation between testosterone measurements in men of similar ages. In healthy nonobese men, 19 to 39 years, harmonized 2.5th, 5th, 50th, 95th, and 97.5th percentile values were 264, 303, 531, 852, and 916 ng/dL, respectively. Age-specific harmonized testosterone concentrations in nonobese men were similar across cohorts and greater than in all men. Conclusion: Harmonized normal range in a healthy nonobese population of European and American men, 19 to 39 years, is 264 to 916 ng/dL. A substantial proportion of intercohort variation in testosterone levels is due to assay differences. These data demonstrate the feasibility of generating harmonized reference ranges for testosterone that can be applied to assays, which have been calibrated to a reference method and calibrator. PMID:28324103
Evaluation of the normal range of values for uptake of radioactive iodine by the thyroid gland.
Schober, B.; Hunt, J. A.
1976-01-01
Uptake of radioactive iodine by the thyroid gland after oral administration of 75 muCi was determined in 1971-72 in 60 euthyroid female volunteers from the North Shore of Vancouver. Values were as low as 3% at 4 hours and 7% at 24 hours in subjects otherwise proven to be euthyroid. The highest values found were 13 and 26% at 4 and 24 hours. The effective thyroxine ratios were all within the accepted normal range. However, more than half of the volunteers showed some enlargement of the thyroid gland. These results suggest an increased iodine pool in the subjects, the likley source being iodine in mild, dairy products and erythrosine, a colouring agent in foods and pharmaceutical products. Potassium iodate, used sometimes in bread baking, contributed little to this pool in our sample. Subjects were, on the average, 9 to 25% heavier than their peers 20 years ago. PMID:1277057
... measurement for a result of this test. Normal value ranges may vary slightly among different laboratories. Some labs use different measurements or test different samples. Talk to your provider ...
Dose coefficients in pediatric and adult abdominopelvic CT based on 100 patient models.
Tian, Xiaoyu; Li, Xiang; Segars, W Paul; Frush, Donald P; Paulson, Erik K; Samei, Ehsan
2013-12-21
Recent studies have shown the feasibility of estimating patient dose from a CT exam using CTDI(vol)-normalized-organ dose (denoted as h), DLP-normalized-effective dose (denoted as k), and DLP-normalized-risk index (denoted as q). However, previous studies were limited to a small number of phantom models. The purpose of this work was to provide dose coefficients (h, k, and q) across a large number of computational models covering a broad range of patient anatomy, age, size percentile, and gender. The study consisted of 100 patient computer models (age range, 0 to 78 y.o.; weight range, 2-180 kg) including 42 pediatric models (age range, 0 to 16 y.o.; weight range, 2-80 kg) and 58 adult models (age range, 18 to 78 y.o.; weight range, 57-180 kg). Multi-detector array CT scanners from two commercial manufacturers (LightSpeed VCT, GE Healthcare; SOMATOM Definition Flash, Siemens Healthcare) were included. A previously-validated Monte Carlo program was used to simulate organ dose for each patient model and each scanner, from which h, k, and q were derived. The relationships between h, k, and q and patient characteristics (size, age, and gender) were ascertained. The differences in conversion coefficients across the scanners were further characterized. CTDI(vol)-normalized-organ dose (h) showed an exponential decrease with increasing patient size. For organs within the image coverage, the average differences of h across scanners were less than 15%. That value increased to 29% for organs on the periphery or outside the image coverage, and to 8% for distributed organs, respectively. The DLP-normalized-effective dose (k) decreased exponentially with increasing patient size. For a given gender, the DLP-normalized-risk index (q) showed an exponential decrease with both increasing patient size and patient age. The average differences in k and q across scanners were 8% and 10%, respectively. This study demonstrated that the knowledge of patient information and CTDIvol/DLP values may be used to estimate organ dose, effective dose, and risk index in abdominopelvic CT based on the coefficients derived from a large population of pediatric and adult patients.
Dose coefficients in pediatric and adult abdominopelvic CT based on 100 patient models
NASA Astrophysics Data System (ADS)
Tian, Xiaoyu; Li, Xiang; Segars, W. Paul; Frush, Donald P.; Paulson, Erik K.; Samei, Ehsan
2013-12-01
Recent studies have shown the feasibility of estimating patient dose from a CT exam using CTDIvol-normalized-organ dose (denoted as h), DLP-normalized-effective dose (denoted as k), and DLP-normalized-risk index (denoted as q). However, previous studies were limited to a small number of phantom models. The purpose of this work was to provide dose coefficients (h, k, and q) across a large number of computational models covering a broad range of patient anatomy, age, size percentile, and gender. The study consisted of 100 patient computer models (age range, 0 to 78 y.o.; weight range, 2-180 kg) including 42 pediatric models (age range, 0 to 16 y.o.; weight range, 2-80 kg) and 58 adult models (age range, 18 to 78 y.o.; weight range, 57-180 kg). Multi-detector array CT scanners from two commercial manufacturers (LightSpeed VCT, GE Healthcare; SOMATOM Definition Flash, Siemens Healthcare) were included. A previously-validated Monte Carlo program was used to simulate organ dose for each patient model and each scanner, from which h, k, and q were derived. The relationships between h, k, and q and patient characteristics (size, age, and gender) were ascertained. The differences in conversion coefficients across the scanners were further characterized. CTDIvol-normalized-organ dose (h) showed an exponential decrease with increasing patient size. For organs within the image coverage, the average differences of h across scanners were less than 15%. That value increased to 29% for organs on the periphery or outside the image coverage, and to 8% for distributed organs, respectively. The DLP-normalized-effective dose (k) decreased exponentially with increasing patient size. For a given gender, the DLP-normalized-risk index (q) showed an exponential decrease with both increasing patient size and patient age. The average differences in k and q across scanners were 8% and 10%, respectively. This study demonstrated that the knowledge of patient information and CTDIvol/DLP values may be used to estimate organ dose, effective dose, and risk index in abdominopelvic CT based on the coefficients derived from a large population of pediatric and adult patients.
Is liver SUV stable over time in ¹⁸F-FDG PET imaging?
Laffon, Eric; Adhoute, Xavier; de Clermont, Henri; Marthan, Roger
2011-12-01
This work investigated whether (18)F-FDG PET standardized uptake value (SUV) is stable over time in the normal human liver. The SUV-versus-time curve, SUV(t), of (18)F-FDG in the normal human liver was derived from a kinetic model analysis. This derivation involved mean values of (18)F-FDG liver metabolism that were obtained from a patient series (n = 11), and a noninvasive population-based input function was used in each individual. Mean values (±95% reliability limits) of the (18)F-FDG uptake and release rate constant and of the fraction of free tracer in blood and interstitial volume were as follows: K = 0.0119 mL·min(-1)·mL(-1) (±0.0012), k(R) = 0.0065·min(-1) (±0.0009), and F = 0.21 mL·mL(-1) (±0.11), respectively. SUV(t) (corrected for (18)F physical decay) was derived from these mean values, showing that it smoothly peaks at 75-80 min on average after injection and that it is within 5% of the peak value between 50 and 110 min after injection. In the normal human liver, decay-corrected SUV(t) remains nearly constant (with a reasonable ±2.5% relative measurement uncertainty) if the time delay between tracer injection and PET acquisition is in the range of 50-110 min. In current clinical practice, the findings suggest that SUV of the normal liver can be used for comparison with SUV of suspected malignant lesions, if comparison is made within this time range.
Jambor, Ivan; Merisaari, Harri; Aronen, Hannu J; Järvinen, Jukka; Saunavaara, Jani; Kauko, Tommi; Borra, Ronald; Pesola, Marko
2014-05-01
To determine the optimal b-value distribution for biexponential diffusion-weighted imaging (DWI) of normal prostate using both a computer modeling approach and in vivo measurements. Optimal b-value distributions for the fit of three parameters (fast diffusion Df, slow diffusion Ds, and fraction of fast diffusion f) were determined using Monte-Carlo simulations. The optimal b-value distribution was calculated using four individual optimization methods. Eight healthy volunteers underwent four repeated 3 Tesla prostate DWI scans using both 16 equally distributed b-values and an optimized b-value distribution obtained from the simulations. The b-value distributions were compared in terms of measurement reliability and repeatability using Shrout-Fleiss analysis. Using low noise levels, the optimal b-value distribution formed three separate clusters at low (0-400 s/mm2), mid-range (650-1200 s/mm2), and high b-values (1700-2000 s/mm2). Higher noise levels resulted into less pronounced clustering of b-values. The clustered optimized b-value distribution demonstrated better measurement reliability and repeatability in Shrout-Fleiss analysis compared with 16 equally distributed b-values. The optimal b-value distribution was found to be a clustered distribution with b-values concentrated in the low, mid, and high ranges and was shown to improve the estimation quality of biexponential DWI parameters of in vivo experiments. Copyright © 2013 Wiley Periodicals, Inc.
Holler, P J; Wess, G
2014-01-01
E-point-to-septal-separation (EPSS) and the sphericity index (SI) are echocardiographic parameters that are recommended in the ESVC-DCM guidelines. However, SI cutoff values to diagnose dilated cardiomyopathy (DCM) have never been evaluated. To establish reference ranges, calculate cutoff values, and assess the clinical value of SI and EPSS to diagnose DCM in Doberman Pinschers. One hundred seventy-nine client-owned Doberman Pinschers. Three groups were formed in this prospective longitudinal study according to established Holter and echocardiographic criteria using the Simpson method of disk (SMOD): control group (97 dogs), DCM with echocardiographic changes (75 dogs) and "last normal" group (n = 7), which included dogs that developed DCM within 1.5 years, but were still normal at this time point. In a substudy, dogs with early DCM based upon SMOD values above the reference range but still normal M-Mode measurements were selected, to evaluate if EPSS or SI were abnormal using the established cutoff values. ROC-curve analysis determined <1.65 for the SI (sensitivity 86.8%; specificity 87.6%) and >6.5 mm for EPSS (sensitivity 100%; specificity 99.0%) as optimal cutoff values to diagnose DCM. Both parameters were significantly different between the control group and the DCM group (P < 0.001), but were not abnormal in the "last normal" group. In the substudy, EPSS was abnormal in 13/13 dogs and SI in 2/13 dogs. E-point-to-septal-separation is a valuable additional parameter for the diagnosis of DCM, which can enhance diagnostic capabilities of M-Mode and which performs similar as well as SMOD. Copyright © 2013 by the American College of Veterinary Internal Medicine.
The Inverted Student Density and Test Scores.
ERIC Educational Resources Information Center
Boldt, Robert F.
The inverted density is one whose contour lines are spheroidal as in the normal distribution, but whose moments differ from those of the normal in that its conditional arrays are not homoscedastic, being quadratic functions of the values of the linear regression functions. It is also platykurtic, its measure of kurtosis ranging from that of the…
NASA Astrophysics Data System (ADS)
Haines, Samuel; Marone, Chris; Saffer, Demian
2014-12-01
The mechanics of slip on low-angle normal faults (LANFs) remain an enduring problem in structural geology and fault mechanics. In most cases, new faults should form rather than having slip occur on LANFs, assuming values of fault friction consistent with Byerlee's Law. We present results of laboratory measurements on the frictional properties of natural clay-rich gouges from low-angle normal faults (LANF) in the American Cordillera, from the Whipple Mts. Detachment, the Panamint range-front detachment, and the Waterman Hills detachment. These clay-rich gouges are dominated by neoformed clay minerals and are an integral part of fault zones in many LANFs, yet their frictional properties under in situ conditions remain relatively unknown. We conducted measurements under saturated and controlled pore pressure conditions at effective normal stresses ranging from 20 to 60 MPa (corresponding to depths of 0.9-2.9 km), on both powdered and intact wafers of fault rock. For the Whipple Mountains detachment, friction coefficient (μ) varies depending on clast content, with values ranging from 0.40 to 0.58 for clast-rich material, and 0.29-0.30 for clay-rich gouge. Samples from the Panamint range-front detachment were clay-rich, and exhibit friction values of 0.28 to 0.38, significantly lower than reported from previous studies on fault gouges tested under room humidity (nominally dry) conditions, including samples from the same exposure. Samples from the Waterman Hills detachment are slightly stronger, with μ ranging from 0.38 to 0.43. The neoformed gouge materials from all three localities exhibits velocity-strengthening frictional behavior under almost all of the experimental conditions we explored, with values of the friction rate parameter (a - b) ranging from -0.001 to +0.025. Clast-rich samples exhibited frictional healing (strength increases with hold time), whereas clay-rich samples do not. Our results indicate that where clay-rich neoformed gouges are present along LANFs, they provide a mechanically viable explanation for slip on faults with dips <20°, requiring only moderate (Pf <σ3) overpressures and/or correcting for ∼5° of footwall tilting. Furthermore, the low rates of frictional strength recovery and velocity-strengthening frictional behavior we observe provide an explanation for the lack of observed seismicity on these structures. We suggest that LANFs in the upper crust (depth <8 km) slip via a combination of a) reaction-weakening of initially high-angle fault zones by the formation of neoformed clay-rich gouges, and b) regional tectonic accommodation of rotating fault blocks.
Sanz-Peláez, O; Angel-Moreno, A; Tapia-Martín, M; Conde-Martel, A; Carranza-Rodríguez, C; Carballo-Rastrilla, S; Soria-López, A; Pérez-Arellano, J L
2008-09-01
The progressive increase in the number of immigrants to Spain in recent years has made it necessary for health-care professionals to be aware about the specific characteristics of this population. An attempt is made in this study to define the normal range of common laboratory values in healthy sub-Saharan adults. Common laboratory values were studied (blood cell counts, clotting tests and blood biochemistry values) and were measured in 150 sub-Saharan immigrants previously defined as healthy according to a complete health evaluation that included a clinical history, physical examination, serologic tests and study of stool parasites. These results were compared to those from a control group consisting of 81 age-and-sex matched healthy blood donors taken from the Spanish native population. Statistically significant differences were obtained in the following values. Mean corpuscular volume (MCV), red cell distribution width (RDW), total leukocytes, and serum levels of creatinine, uric acid, total protein content, creatin-kinase (CK), aspartate aminotransferase (AST), gamma-glutamyl-transpeptidase (GGT), Immunoglobulin G (IgG) and M (IgM). If evaluated according to the normal values in native people, a considerable percentage of healthy sub-Saharan immigrants would present
Compton profiles of some composite materials normalized by a new method
NASA Astrophysics Data System (ADS)
Sankarshan, B. M.; Umesh, T. K.
2018-03-01
Recently, we have shown that as a novel approach, in the case of samples which can be treated as pure incoherent scatterers, the effective atomic number Zeff itself could be conveniently used to normalize their un-normalized Compton profiles. In the present investigation, we have attempted to examine the efficacy of this approach. For this purpose, we have first determined the single differential Compton scattering cross sections (SDCS) of the elements C and Al as well as of some H, C, N and O based polymer samples such as bakelite, epoxy, nylon and teflon which are pure incoherent scatterers. The measurements were made at 120° in a goniometer assembly that employs a high resolution high purity germanium detector. The SDCS values were used to obtain the Zeff and the un-normalized Compton profiles. These Compton profiles were separately normalized with their Zeff values (for Compton scattering) as well as with the normalization constant obtained by integrating their Hartree-Fock Biggs et al Compton profiles based on the mixture rule. These two sets of values agreed well within the range of experimental errors, implying that Zeff can be conveniently used to normalize the experimental Compton profiles of pure incoherent scatterers.
Immunological monitoring of dry-cleaning shop workers--exposure to tetrachloroethylene.
Andrýs, C; Hanovcová, I; Chýlková, V; Tejral, J; Eminger, S; Procházková, J
1997-09-01
A panel of immunological parameters has been examined in a group of dry-cleaning workers (n = 21) and in a control group of administrators (n = 16) from the same plant. The results were also compared to long-term laboratory reference values (LRV) (n = 14-311). External exposure to tetrachloroethylene (PER) was represented by TWA (8 h) values in the range 11-752 mg PER/m3. Biological monitoring showed an amount from 9 to 344 mg PER/m3 in exhaled air by the end of workshift. 1. The exposed dry-cleaning workers compared to the controls from the plant had statistically significant changes in metabolic activity of phagocytes, alpha 2-macroglobulin, C3 and C4 complement component, salivary secretory IgA, and blastic transformation test. Most of the values were within the range of normal values. 2. The exposed dry-cleaning workers had several abnormal immune parameters compared to the long-term laboratory values (LRV) especially in the alpha 2-macroglobulin, C3 and percentage of T-lymphocytes. Most of the changes, even those that were statistically significant, were still within the range of normal values, but they might be classified as trends or shifts away from normal (spontaneous blastic transformation, absolute number of phagocyting cells, coeruloplasmin, circulating immunocomplexes, serum lysozyme). 3. The non-exposed controls from the same plant showed both quantitative and qualitative differences when compared to the LRV. Changes were seen in IgG, C4, CSI and in increased spontaneous metabolic activity of leucocytes, total leucocyte count, absolute number of phagocyting cells, alpha 2-macroglobulin, prealbumin, C4, circulating immunocomplexes and serum lysozyme. 4. The distribution analysis of all results detected a large number of abnormal values in both groups, more in the at-risk group. 5. As inhalation was the main route of PER exposure it was concluded that the changes might represent aspects of the response of the respiratory immune system, mainly of the alveolar macrophages. Additional postinfection effects could not be excluded in both studied groups. Individual differences in immune reactivity as well as individual range of exposure should be taken into consideration.
Han, Xiaowei; Li, Junfeng; Wang, Xiaoyi
2017-04-01
Breast 3.0 T magnetic resonance diffusion-weighted imaging (MR-DWI) of benign and malignant lesions were obtained to measure and calculate the signal-to-noise ratio (SNR), signal intensity ratio (SIR), and contrast-to-noise ratio (CNR) of lesions at different b-values. The variation patterns of SNR and SIR were analyzed with different b-values and the images of DWI were compared at four different b-values with higher image quality. The effect of SIR on the differential diagnostic efficiency of benign and malignant lesions was compared using receiver operating characteristic curves to provide a reference for selecting the optimal b-value. A total of 96 qualified patients with 112 lesions and 14 patients with their contralateral 14 normal breasts were included in this study. The single-shot echo planar imaging sequence was used to perform the DWI and a total of 13 b-values were used: 0, 50, 100, 200, 400, 600, 800, 1000, 1200, 1500, 1800, 2000, and 2500 s/mm 2 . On DWI, the suitable regions of interest were selected. The SNRs of normal breasts (SNR normal ), SNR lesions , SIR, and CNR of benign and malignant lesions were measured on DWI with different b-values and calculated. The variation patterns of SNR, SIR, and CNR values on DWI for normal breasts, benign lesions, and malignant lesions with different b-values were analyzed by using Pearson correlation analysis. The SNR and SIR of benign and malignant lesions with the same b-values were compared using t-tests. The diagnostic efficiencies of SIR with different b-values for benign and malignant lesions were evaluated using receiver operating characteristic curves. Breast DWI had higher CNR for b-values ranging from 600 to 1200 s/mm 2 . It had the best CNR at b = 1000 s/mm 2 for the benign lesions and at b = 1200 s/mm 2 for the malignant lesions. The signal intensity and SNR values of normal breasts decreased with increasing b-values, with a negative correlation (r = -0.945, P < 0.01). The mean SNR values of benign and malignant lesions were negatively correlated (r = -0.982 and -0.947, respectively, and P < 0.01), gradually decreasing with increasing b-values. The mean SIR value of benign lesions gradually decreased with increasing b-values, a negative correlation (r = -0.991, P < 0.01). The mean SIR values of malignant lesions gradually increased with increasing b-values between 0 and 1200 s/mm 2 , and gradually decreased with increasing b-values ≥ 1500 s/mm 2 . For b-values of 600, 800, 1000, and 1200 s/mm 2 , the sensitivity and specificity of SIR in identifying benign and malignant lesions gradually increased with increasing b-values, peaking at 1200 s/mm 2 . Breast DWI had higher image quality for b-values ranging from 600 to 1200 s/mm 2 , and was best for b-values ranging from 1000 to 1200 s/mm 2 . The SIR had the highest diagnostic efficiency in differentiating benign and malignant lesions for a b-value of 1200 s/mm 2 . Copyright © 2017 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.
The Pathogenic Role of Low Range Repeats in SCA17.
Shin, Jung Hwan; Park, Hyeyoung; Ehm, Gwan Hee; Lee, Woong Woo; Yun, Ji Young; Kim, Young Eun; Lee, Jee-Young; Kim, Han-Joon; Kim, Jong-Min; Jeon, Beom Seok; Park, Sung-Sup
2015-01-01
SCA17 is an autosomal dominant cerebellar ataxia with expansion of the CAG/CAA trinucleotide repeats in the TATA-binding protein (TBP) gene. SCA17 can have various clinical presentations including parkinsonism, ataxia, chorea and dystonia. SCA17 is diagnosed by detecting the expanded CAG repeats in the TBP gene; however, in the literature, pathologic repeat numbers as low as 41 overlap with normal repeat numbers. The subjects in this study included patients with involuntary movement disorders such as cerebellar ataxia, parkinsonism, chorea and dystonia who visited Seoul National University Hospital between Jan. 2006 and Apr. 2014 and were screened for SCA17. Those who were diagnosed with other genetic diseases or nondegenerative diseases were excluded. DNA from healthy subjects who did not have a family history of parkinsonism, ataxia, psychiatric symptoms, chorea or dystonia served as the control. In total, 5242 chromosomes from 2099 patients and 522 normal controls were analyzed. The total number of patients included in the analysis was 2099 (parkinsonism, 1706; ataxia, 345; chorea, 37; and dystonia, 11). In the normal control, up to 44 repeats were found. In the 44 repeat group, there were 7 (0.3%) patients and 1 (0.2%) normal control. In 43 repeat group, there were 8 (0.4%) patients and 2 (0.4%) normal controls. In the 42 repeat group, there were 16 (0.8%) patients and 3 (0.6%) normal controls. In 41 repeat group, there were 48 (2.3%) patients and 8 (1.5%) normal controls. Considering the overlaps and non-significant differences in allelic frequencies between the patients and the normal controls with low-expansions, we could not determine a definitive cutoff value for the pathologic CAG repeat number of SCA17. Because the statistical analysis between the normal controls and patients with low range expansions failed to show any differences so far, we must consider that clinical cases with low range expansions could be idiopathic movement disorders showing coincidental CAG/CAA expansions. Thus, we need to reconsider the pathologic role of low range expansions (41-42). Long term follow up and comprehensive investigations using autopsy and imaging studies in patients and controls with low range expansions are necessary to determine the cutoff value for the pathologic CAG repeat number of SCA17.
[Research of Identify Spatial Object Using Spectrum Analysis Technique].
Song, Wei; Feng, Shi-qi; Shi, Jing; Xu, Rong; Wang, Gong-chang; Li, Bin-yu; Liu, Yu; Li, Shuang; Cao Rui; Cai, Hong-xing; Zhang, Xi-he; Tan, Yong
2015-06-01
The high precision scattering spectrum of spatial fragment with the minimum brightness of 4.2 and the resolution of 0.5 nm has been observed using spectrum detection technology on the ground. The obvious differences for different types of objects are obtained by the normalizing and discrete rate analysis of the spectral data. Each of normalized multi-frame scattering spectral line shape for rocket debris is identical. However, that is different for lapsed satellites. The discrete rate of the single frame spectrum of normalized space debris for rocket debris ranges from 0.978% to 3.067%, and the difference of oscillation and average value is small. The discrete rate for lapsed satellites ranges from 3.118 4% to 19.472 7%, and the difference of oscillation and average value relatively large. The reason is that the composition of rocket debris is single, while that of the lapsed satellites is complex. Therefore, the spectrum detection technology on the ground can be used to the classification of the spatial fragment.
Assessment of the hygienic performances of hamburger patty production processes.
Gill, C O; Rahn, K; Sloan, K; McMullen, L M
1997-05-20
The hygienic conditions of the hamburger patties collected from three patty manufacturing plants and six retail outlets were examined. At each manufacturing plant a sample from newly formed, chilled patties and one from frozen patties were collected from each of 25 batches of patties selected at random. At three, two or one retail outlet, respectively, 25 samples from frozen, chilled or both frozen and chilled patties were collected at random. Each sample consisted of 30 g of meat obtained from five or six patties. Total aerobic, coliform and Escherichia coli counts per gram were enumerated for each sample. The mean log (x) and standard deviation (s) were calculated for the log10 values for each set of 25 counts, on the assumption that the distribution of counts approximated the log normal. A value for the log10 of the arithmetic mean (log A) was calculated for each set from the values of x and s. A chi2 statistic was calculated for each set as a test of the assumption of the log normal distribution. The chi2 statistic was calculable for 32 of the 39 sets. Four of the sets gave chi2 values indicative of gross deviation from log normality. On inspection of those sets, distributions obviously differing from the log normal were apparent in two. Log A values for total, coliform and E. coli counts for chilled patties from manufacturing plants ranged from 4.4 to 5.1, 1.7 to 2.3 and 0.9 to 1.5, respectively. Log A values for frozen patties from manufacturing plants were between < 0.1 and 0.5 log10 units less than the equivalent values for chilled patties. Log A values for total, coliform and E. coli counts for frozen patties on retail sale ranged from 3.8 to 8.5, < 0.5 to 3.6 and < 0 to 1.9, respectively. The equivalent ranges for chilled patties on retail sale were 4.8 to 8.5, 1.8 to 3.7 and 1.4 to 2.7, respectively. The findings indicate that the general hygienic condition of hamburgers patties could be improved by their being manufactured from only manufacturing beef of superior hygienic quality, and by the better management of chilled patties at retail outlets.
Use of the variable gain settings on SPOT
Chavez, P.S.
1989-01-01
Often the brightness or digital number (DN) range of satellite image data is less than optimal and uses only a portion of the available values (0 to 255) because the range of reflectance values is small. Most imaging systems have been designed with only two gain settings, normal and high. The SPOT High Resolution Visible (HRV) imaging system has the capability to collect image data using one of eight different gain settings. With the proper procedure this allows the brightness or reflectance resolution, which is directly related to the range of DN values recorded, to be optimized for any given site as compared to using a single set of gain settings everywhere. -from Author
Normal and pathological serum levels of alpha2-macroglobulins in men and mice.
Tunstall, A M; Merriman, J M; Milne, I; James, K
1975-01-01
The serum levels of alpha2-macroglobulin have been measured in normal men and mice and in a number of immunopathological conditions. Normal human concentrations are high in youth, reach their minimum in middle age, and gradually increase with old age. In all age groups the mean is higher in the female than in the male. Conversely, in normal mice the alpha2M level is low in youth, maximum in middle age, and shows a slight depression with old age, and the levels are frequently higher in males than in females; there are also strain variations. In human immunopathological conditions, there are some deviations from the normal alpha2M level but these are seen to be changes from the normal distribution of values around the mean, rather than significant elevation or depression of mean values. In some disease states studied there are differences between the sexes in the deviation from normal. "Abnormal" strains of mice had alpha2M levels within the range exhibited by "normal" mice but changes in the levels are seen in mice with various myelomas. Images PMID:47865
Nelson, Winnie W; Desai, Sunita; Damaraju, Chandrasekharrao V; Lu, Lang; Fields, Larry E; Wildgoose, Peter; Schein, Jeffery R
2015-06-01
Maintaining stable levels of anticoagulation using warfarin therapy is challenging. Few studies have examined the stability of the international normalized ratio (INR) in patients with nonvalvular atrial fibrillation (NVAF) who have had ≥6 months' exposure to warfarin anticoagulation for stroke prevention. Our objective was to describe INR control in NVAF patients who had been receiving warfarin for at least 6 months. Using retrospective patient data from the CoagClinic™ database, we analyzed data from NVAF patients treated with warfarin to assess the quality of INR control and possible predictors of poor INR control. Time within, above, and below the recommended INR range (2.0-3.0) was calculated for patients who had received warfarin for ≥6 months and had three or more INR values. The analysis also assessed INR patterns and resource utilization of patients with an INR >4.0. Logistic regression models were used to determine factors associated with poor INR control. Patients (n = 9433) had an average of 1.6 measurements per 30 days. Mean follow-up time was 544 days. Approximately 39% of INR values were out of range, with 23% of INR values being <2.0 and 16% being >3.0. Mean percent time with INR in therapeutic range was 67%; INR <2.0 was 19% and INR >3.0 was 14%. Patients with more than one reading of INR >4.0 (~39%) required an average of one more visit and took 3 weeks to return to an in-range INR. Male sex and age >75 years were predictive of better INR control, whereas a history of heart failure or diabetes were predictive of out-of-range INR values. However, patient characteristics did not predict the likelihood of INR >4.0. Out-of-range INR values remain frequent in patients with NVAF treated with warfarin. Exposure to high INR values was common, resulting in increased resource utilization.
The narrow therapeutic window of glycated hemoglobin and assay variability.
Hosseini, S S; Bibler, I; Charles, M A
1999-12-01
Glycated hemoglobin is measured by a variety of assays, each of which has a unique normal level. Our purpose is to show that among the different assays available in the United States, using the same patient's blood sample, assay results may vary widely and may more or less easily achieve a glycated hemoglobin value within the normal range. The following assays were compared using the same patient's blood sample for each pair of assays: glycohemoglobin affinity assay (GHB Reader; Isolab, Akron, OH) versus gel electrophoresis assay (n = 76); Isolab versus ion capture assay (IMX; Abbott Laboratories, Irving, TX) (n = 57); monoclonal antibody assay (DCA2000; Bayer Diagnostics, Pittsburgh, PA) versus IMX (n = 100); and high-performance liquid chromatography (HPLC) assay (Bio-Rad Variant A1c; Bio-Rad Laboratories, Richmond, CA) versus IMX assay (n = 55). Our analyses indicate that a relative ranking can be established for the ease of achieving a normal glycated hemoglobin level. The ranking indicates that the most stringent or difficult assays for achieving a normal level are the Isolab and DCA2000 assays. The intermediate assays are the IMX and Bio-Rad Variant, and the easiest method for achieving a normal value is the gel electrophoresis assay. Our results indicate that various glycated hemoglobin assays vary widely and are associated with more or less difficulty for an individual patient to achieve a glycated hemoglobin level within the normal range. These results are especially significant with respect to (1) the clinically narrow therapeutic window of glycated hemoglobin values in type 1 diabetes to avoid rapidly advancing severe hypoglycemia rates and chronic microvascular complication rates, and (2) the glycated hemoglobin threshold for rapidly advancing macrovascular disease in both type 1 and type 2 patients.
Prognostic value of repeated serum CA 125 measurements in first trimester pregnancy.
Schmidt, T; Rein, D T; Foth, D; Eibach, H W; Kurbacher, C M; Mallmann, P; Römer, T
2001-08-01
To assess the diagnostic value of maternal CA 125 in patients with symptomatic first trimester pregnancy and to evaluate the prognostic significance of CA 125 versus beta-hCG in early pregnancies with intact fetal heartbeat, complicated by vaginal bleeding. Two prospective open-label studies with longitudinal follow-up in the second trial. Academic Department of Obstetrics and Gynecology, University of Cologne. Study 1: 168 patients presenting between gestational weeks 6 and 12 with: extrauterine pregnancy, 29; missed abortion, 50; incomplete spontaneous abortion, 38; imminent abortion, 33; and normal pregnancy (no history of endometriosis or ovarian mass), 18. Study 2: Fifty consecutive patients with vaginal bleeding during gestational weeks 6-12 all of whom having demostrable fetal heartbeat. Eighteen patients finally aborted whereas the remainder had normally continuing pregnancy until term. Study 1: Single serum determinations of CA 125 and beta-hCG were correlated with the different disorders observed. Study 2: Two sequential measurements of serum CA 125 and beta-hCG performed within a 5-7 days interval were related to the outcome of pregnancy as indicated by changes of the ultrasound presentation, miscarriage, future hospitalization, or delivery. Study 1: Patients with vaginal bleeding generally had higher median CA 125 values (38 IU/ml; range 1.3-540) compared to non-bleeding patients (17.8 IU/ml; range 1.0-157). No statistically significant differences in regard to median serum CA 125 levels between symptomatic and normal pregnancies occurred: normal pregnancy, 25.5 IU/ml (range 3.2-97); ectopic pregnancy, 26 IU/ml (range 1.3-157); missed abortion, 19.1IU/ml (range 1-242); threatened abortion, 48 IU/ml (range 5.2-540); spontaneous abortion, 40 IU/ml (range 5.4-442). Study 2: Initial CA 125 levels did not differ significantly between both groups of patients with 27/32 non-aborters and 13/18 aborters showing concentrations below 65 IU/ml. After 5-7 days, CA 125 in all patients who eventually aborted remained high or increased whereas non-aborters all had constantly low or steeply declining CA 125 measures. beta-hCG increased in all non-aborters but also in 13/18 aborters during the 5-7 day interval. Single serum measurements of CA 125 in symptomatic first trimester pregnant patients failed to discriminate spontaneous abortion, ectopic or normal pregnancies. However, sequential determinations of maternal CA 125 measurements appear to be a highly sensitive prognostic marker in patients with viable pregnancy at risk for abortion.
Colour vision in AIDS patients without HIV retinopathy.
Sommerhalder, J; Baglivo, E; Barbey, C; Hirschel, B; Roth, A; Pelizzone, M
1998-11-01
Patients suffering from AIDS develop ocular complications, the most frequent being HIV retinopathy. It is however not clear, if functional visual impairments can be observed as early indicators of ocular complications, before clinical diagnosis of HIV retinopathy is made at fundus examination. To address this issue, we measured colour vision in a group of 49 AIDS subjects with normal clinical fundi using the 'two equation method'. This method, combining red-green Rayleigh and the blue-green Moreland metameric matches, enables more complete and quantitative assessments of colour vision than those based on pigmentary tests. Data were collected on our computer controlled colorimeter and compared to those of normal subjects. While most AIDS subjects without HIV retinopathy demonstrated normal colour vision, a significant portion of them had wider matches than normal subjects (11% for the Rayleigh equation and 16% for the Moreland equation). Furthermore, matching ranges of the Moreland equation were significantly correlated with CD4 lymphocyte counts. Patients with low CD4 values tended to produce larger matching ranges than the patients with high CD4 values. A within subject study on 17 patients confirmed this trend and showed that the patients who increased/decreased their CD4 blood counts generally improved/impaired their colour discrimination in the Moreland match. No such correlation was found between the matching ranges of the Rayleigh equation and the CD4 counts. These results show that colour discrimination is slightly reduced in some AIDS subjects, although there are no detectable ocular complications. They also suggest two different types of colour vision impairments in AIDS patients without retinopathy: one reversible process affecting colour discrimination in the blue-green range; and another irreversible process affecting colour discrimination in the red-green range.
Adaptive Value Normalization in the Prefrontal Cortex Is Reduced by Memory Load.
Holper, L; Van Brussel, L D; Schmidt, L; Schulthess, S; Burke, C J; Louie, K; Seifritz, E; Tobler, P N
2017-01-01
Adaptation facilitates neural representation of a wide range of diverse inputs, including reward values. Adaptive value coding typically relies on contextual information either obtained from the environment or retrieved from and maintained in memory. However, it is unknown whether having to retrieve and maintain context information modulates the brain's capacity for value adaptation. To address this issue, we measured hemodynamic responses of the prefrontal cortex (PFC) in two studies on risky decision-making. In each trial, healthy human subjects chose between a risky and a safe alternative; half of the participants had to remember the risky alternatives, whereas for the other half they were presented visually. The value of safe alternatives varied across trials. PFC responses adapted to contextual risk information, with steeper coding of safe alternative value in lower-risk contexts. Importantly, this adaptation depended on working memory load, such that response functions relating PFC activity to safe values were steeper with presented versus remembered risk. An independent second study replicated the findings of the first study and showed that similar slope reductions also arose when memory maintenance demands were increased with a secondary working memory task. Formal model comparison showed that a divisive normalization model fitted effects of both risk context and working memory demands on PFC activity better than alternative models of value adaptation, and revealed that reduced suppression of background activity was the critical parameter impairing normalization with increased memory maintenance demand. Our findings suggest that mnemonic processes can constrain normalization of neural value representations.
NASA Astrophysics Data System (ADS)
Lam, Simon K. H.
2017-09-01
A promising direction to improve the sensitivity of a SQUID is to increase its junction's normal resistance value, Rn, as the SQUID modulation voltage scales linearly with Rn. As a first step to develop highly sensitive single layer SQUID, submicron scale YBCO grain boundary step edge junctions and SQUIDs with large Rn were fabricated and studied. The step-edge junctions were reduced to submicron scale to increase their Rn values using focus ion beam, FIB and the measurement of transport properties were performed from 4.3 to 77 K. The FIB induced deposition layer proves to be effective to minimize the Ga ion contamination during the FIB milling process. The critical current-normal resistance value of submicron junction at 4.3 K was found to be 1-3 mV, comparable to the value of the same type of junction in micron scale. The submicron junction Rn value is in the range of 35-100 Ω, resulting a large SQUID modulation voltage in a wide temperature range. This performance promotes further investigation of cryogen-free, high field sensitivity SQUID applications at medium low temperature, e.g. at 40-60 K.
... above 35 U/mL is considered abnormal. Normal value ranges may vary slightly among different laboratories. Some ... 125 usually does not mean ovarian cancer is present. Most healthy women with an elevated CA-125 ...
Measurement of Physiologic Glucose Levels Using Raman Spectroscopy in a Rabbit Aqueous Humor Model
NASA Technical Reports Server (NTRS)
Lambert, J.; Storrie-Lombardi, M.; Borchert, M.
1998-01-01
We have elecited a reliable glucose signature in mammalian physiological ranges using near infrared Raman laser excitation at 785 nm and multivariate analysis. In a recent series of experiments we measured glucose levels in an artificial aqueous humor in the range from 0.5 to 13X normal values.
Nonparametric spirometry reference values for Hispanic Americans.
Glenn, Nancy L; Brown, Vanessa M
2011-02-01
Recent literature sites ethnic origin as a major factor in developing pulmonary function reference values. Extensive studies established reference values for European and African Americans, but not for Hispanic Americans. The Third National Health and Nutrition Examination Survey defines Hispanic as individuals of Spanish speaking cultures. While no group was excluded from the target population, sample size requirements only allowed inclusion of individuals who identified themselves as Mexican Americans. This research constructs nonparametric reference value confidence intervals for Hispanic American pulmonary function. The method is applicable to all ethnicities. We use empirical likelihood confidence intervals to establish normal ranges for reference values. Its major advantage: it is model free, but shares asymptotic properties of model based methods. Statistical comparisons indicate that empirical likelihood interval lengths are comparable to normal theory intervals. Power and efficiency studies agree with previously published theoretical results.
Sorokin, Victoria; Alkhoury, Razan; Al-Rawabdeh, Sura; Houston, Ronald H; Thornton, David; Kerlin, Bryce; O'Brien, Sarah; Baker, Peter; Boesel, Carl; Uddin, Minhaj; Yin, Han; Kahwash, Samir
This study sought to determine delta granule normal ranges for children and to validate methodology for the appropriate diagnosis of delta granule deficiency (storage pool disease) by using the whole-mount technique in electron microscopy. Specimens obtained from 40 healthy volunteers (2 months of age through 21 years old, 21 females and 19 males) were tested. Results showed dense granules/platelet (DG/Plt) ranged from 1.78 to 5.25. The 5th percentile was 1.96 DG/Plt with an overall mean ± SEM 3.07 ± 0.12 DG/Plt. In comparison, a previously published lower cutoff value, 3.68 DG/Plt, was significantly higher than the mean from our volunteers (P < 0.0001). We found no variability in dense granules/platelet based on race or sex and no significant variation by age subgroup. Pending wider studies, the value of 2 DG/Plt is a more appropriate lower limit of normal. In the absence of wider studies (in healthy volunteers and patients), laboratories should consider establishing their own reference ranges.
Hematological reference values of healthy Malaysian population.
Roshan, T M; Rosline, H; Ahmed, S A; Rapiaah, M; Wan Zaidah, A; Khattak, M N
2009-10-01
Health and disease can only be distinguished by accurate and reliable reference values of a particular laboratory test. It is now a proven fact that there is considerable variation in hematology reference intervals depending on the demographic and preanalytical variables. There are evidences that values provided by manufacturers do not have appropriate application for all populations. Moreover, reference ranges provided by different laboratory manuals and books also do not solve this problem. We are presenting here normal reference ranges of Malaysian population. These values were determined by using Sysmex XE-2100 and ACL 9000 hematology and coagulation analyzers. Results from this study showed that there were considerable differences in the reference values from manufacturers, western population or laboratory manuals compared with those from the local population.
The Value Range of Contact Stiffness Factor between Pile and Soil Based on Penalty Function
NASA Astrophysics Data System (ADS)
Chen, Sandy H. L.; Wu, Xinliu
2018-03-01
The value range of contact stiffness factor based on penalty function is studied when we use finite element software ANSYS to analyze contact problems, take single pile and soil of a certain project for example, the normal contact between pile and soil is analyzed with 2D simplified model in horizontal load. The study shows that when adopting linear elastic model to simulate soil, the maximum contact pressure and penetration approach steady value as the contact stiffness factor increases. The reasonable value range of contact stiffness factor reduces as the underlying element thickness decreases, but the rule reverses when refers to the soil stiffness. If choose DP model to simulate soil, the stiffness factor should be magnified 100 times compares to the elastic model regardless of the soil bears small force and still in elastic deformation stage or into the plastic deformation stage. When the soil bears big force and into plastic deformation stage, the value range of stiffness factor relates to the plastic strain range of the soil, and reduces as the horizontal load increases.
... infections. Normal value ranges may vary slightly from one lab to another. Talk to your doctor about the meaning of your test results. What Abnormal Results Mean If the sample does not change color when NBT is added, ...
NASA Astrophysics Data System (ADS)
Cunliffe, Alexandra R.; Al-Hallaq, Hania A.; Fei, Xianhan M.; Tuohy, Rachel E.; Armato, Samuel G.
2013-02-01
To determine how 19 image texture features may be altered by three image registration methods, "normal" baseline and follow-up computed tomography (CT) scans from 27 patients were analyzed. Nineteen texture feature values were calculated in over 1,000 32x32-pixel regions of interest (ROIs) randomly placed in each baseline scan. All three methods used demons registration to map baseline scan ROIs to anatomically matched locations in the corresponding transformed follow-up scan. For the first method, the follow-up scan transformation was subsampled to achieve a voxel size identical to that of the baseline scan. For the second method, the follow-up scan was transformed through affine registration to achieve global alignment with the baseline scan. For the third method, the follow-up scan was directly deformed to the baseline scan using demons deformable registration. Feature values in matched ROIs were compared using Bland- Altman 95% limits of agreement. For each feature, the range spanned by the 95% limits was normalized to the mean feature value to obtain the normalized range of agreement, nRoA. Wilcoxon signed-rank tests were used to compare nRoA values across features for the three methods. Significance for individual tests was adjusted using the Bonferroni method. nRoA was significantly smaller for affine-registered scans than for the resampled scans (p=0.003), indicating lower feature value variability between baseline and follow-up scan ROIs using this method. For both of these methods, however, nRoA was significantly higher than when feature values were calculated directly on demons-deformed followup scans (p<0.001). Across features and methods, nRoA values remained below 26%.
Sugimoto, Tadafumi; Robinet, Sébastien; Dulgheru, Raluca; Bernard, Anne; Ilardi, Federica; Contu, Laura; Addetia, Karima; Caballero, Luis; Kacharava, George; Athanassopoulos, George D; Barone, Daniele; Baroni, Monica; Cardim, Nuno; Hagendorff, Andreas; Hristova, Krasimira; Lopez, Teresa; de la Morena, Gonzalo; Popescu, Bogdan A; Penicka, Martin; Ozyigit, Tolga; Rodrigo Carbonero, Jose David; van de Veire, Nico; Von Bardeleben, Ralph Stephan; Vinereanu, Dragos; Zamorano, Jose Luis; Go, Yun Yun; Marchetta, Stella; Nchimi, Alain; Rosca, Monica; Calin, Andreea; Moonen, Marie; Cimino, Sara; Magne, Julien; Cosyns, Bernard; Galli, Elena; Donal, Erwan; Habib, Gilbert; Esposito, Roberta; Galderisi, Maurizio; Badano, Luigi P; Lang, Roberto M; Lancellotti, Patrizio
2018-06-01
To obtain the normal ranges for echocardiographic measurements of left atrial (LA) function from a large group of healthy volunteers accounting for age and gender. A total of 371 (median age 45 years) healthy subjects were enrolled at 22 collaborating institutions collaborating in the Normal Reference Ranges for Echocardiography (NORRE) study of the European Association of Cardiovascular Imaging (EACVI). Left atrial data sets were analysed with a vendor-independent software (VIS) package allowing homogeneous measurements irrespective of the echocardiographic equipment used to acquire data sets. The lowest expected values of LA function were 26.1%, 48.7%, and 41.4% for left atrial strain (LAS), 2D left atrial emptying fraction (LAEF), and 3D LAEF (reservoir function); 7.7%, 24.2%, and -0.53/s for LAS-active, LAEF-active, and LA strain rate during LA contraction (SRa) (pump function) and 12.0% and 21.6% for LAS-passive and LAEF-passive (conduit function). Left atrial reservoir and conduit function were decreased with age while pump function was increased. All indices of reservoir function and all LA strains had no difference in both gender and vendor. However, inter-vendor differences were observed in LA SRa despite the use of VIS. The NORRE study provides contemporary, applicable echocardiographic reference ranges for LA function. Our data highlight the importance of age-specific reference values for LA functions.
Technetium-99m mercaptoacetyltriglycine clearance: reference values for infants and children.
Schofer, O; König, G; Bartels, U; Bockisch, A; Piepenburg, R; Beetz, R; Meyer, G; Hahn, K
1995-11-01
Six hundred and thirty-nine clearance studies performed in children aged 7 days to 19 years utilizing technetium-99m mercaptoacetyltriglycine (MAG 3) were retrospectively analysed. Standardized conditions for the investigation included: parenteral hydration (60 ml/hxm2 body surface) in addition to normal oral fluid intake, weight-related dose of 99mTc-MAG 3 (1 MBq/kg body weight, minimum 15 MBq) and calculation of clearance according to Bubeck et al. Of the 513 children, 169 included in this analysis could be classified as "normal" with regard to their renal function. Normal kidney function was judged by the following criteria: normal GFR for age, normal tubular function (absence of proteinuria and glucosuria), normal renal parenchyma (on ultrasonography, MAG 3 scan and intravenous pyelography), absence of significant obstruction and gross reflux (>grade I), no single kidney and no difference in split renal function >20%. Results showed increasing MAG 3 clearance values for infants during the first months of life, reaching the normal range for older children and adults between 7 and 12 months.
Mitotane treatment in patients with adrenocortical cancer causes central hypothyroidism.
Russo, Marco; Scollo, Claudia; Pellegriti, Gabriella; Cotta, Oana Ruxandra; Squatrito, Sebastiano; Frasca, Francesco; Cannavò, Salvatore; Gullo, Damiano
2016-04-01
Mitotane, a steroidogenesis inhibitor with adrenolytic properties used to treat adrenocortical cancer (ACC), can affect thyroid function. A reduction of FT4 levels with normal FT3 and TSH has been described in these patients. Using an in vitro murine model, the secretory capacity of thyrotrophic cells has been shown to be inhibited by mitotane. To investigate the pathogenesis of thyroid abnormalities in mitotane-treated patients with ACC. In five female patients with ACC (median age 47; range 31-65) treated with mitotane (dosage 1·5 g/day; 1·0-3·0), we analysed the pattern of TSH and thyroid function index (FT4, FT3 and FT3/FT4 ratio) compared to an age- and gender-matched control group. The in vivo secretory activity of the thyrotrophic cells was evaluated using a standard TRH test (200 μg), and the response was compared to both a group of age-matched female controls (n = 10) and central hypothyroid patients (n = 10). Basal TSH (median 1·54 mU/l; range 1·20-2·17) was normal and scattered around our median reference value, FT3 levels (median 3·80 pmol/l; 3·30-4·29) were normal but below the median reference value of 4·37 pmol/l and FT4 levels were below the normal range in all patients (median 8·40 pmol/l; 7·6-9·9). FT3/FT4 ratio was in the upper range in 4 patients and higher than normal in one patient. A blunted TSH response to TRH was observed in mitotane-treated patients. ΔTSH (absolute TSH response, peak TSH minus basal TSH) was 3·65 (range 3·53-5·26), 12·37 (range 7·55-19·97) and 1·32 mU/l (range 0·52-4·66) in mitotane-treated patients, controls and central hypothyroid patients, respectively. PRL secretion was normal. Mitotane-treated patients with ACC showed low FT4, normal FT3 and TSH and impaired TSH response to TRH, characteristic of central hypothyroidism. Furthermore, the elevated FT3/FT4 ratio of these subjects reflects an enhanced T4 to T3 conversion rate, a compensatory mechanism characteristic of thyroid function changes observed in hypothyroid conditions. This finding thus confirms in vitro studies and may have a therapeutic implication for treatment with thyroid hormones, as suggested by current guidelines for this specific condition. © 2015 John Wiley & Sons Ltd.
Liu, Xiaohang; Zhou, Liangping; Peng, Weijun; Wang, He; Zhang, Yong
2015-10-01
To compare stretched-exponential and monoexponential model diffusion-weighted imaging (DWI) in prostate cancer and normal tissues. Twenty-seven patients with prostate cancer underwent DWI exam using b-values of 0, 500, 1000, and 2000 s/mm(2) . The distributed diffusion coefficients (DDC) and α values of prostate cancer and normal tissues were obtained with stretched-exponential model and apparent diffusion coefficient (ADC) values using monoexponential model. The ADC, DDC (both in 10(-3) mm(2)/s), and α values (range, 0-1) were compared among different prostate tissues. The ADC and DDC were also compared and correlated in each tissue, and the standardized differences between DDC and ADC were compared among different tissues. Data were obtained for 31 cancers, 36 normal peripheral zone (PZ) and 26 normal central gland (CG) tissues. The ADC (0.71 ± 0.12), DDC (0.60 ± 0.18), and α value (0.64 ± 0.05) of tumor were all significantly lower than those of the normal PZ (1.41 ± 0.22, 1.47 ± 0.20, and 0.85 ± 0.09) and CG (1.25 ± 0.14, 1.32 ± 0.13, and 0.82 ± 0.06) (all P < 0.05). ADC was significantly higher than DDC in cancer, but lower than DDC in the PZ and CG (all P < 0.05). The ADC and DDC were strongly correlated (R(2) = 0.99, 0.98, 0.99, respectively, all P < 0.05) in all the tissue, and standardized difference between ADC and DDC of cancer was slight but significantly higher than that in normal tissue. The stretched-exponential model DWI provides more parameters for distinguishing prostate cancer and normal tissue and reveals slight differences between DDC and ADC values. © 2015 Wiley Periodicals, Inc.
Shani, Michal; Vinker, Shlomo; Dinour, Dganit; Leiba, Merav; Twig, Gilad; Holtzman, Eliezer J; Leiba, Adi
2016-10-01
The risk associated with serum uric acid (SUA) levels within the normal range is unknown, especially among lean and apparently healthy adults. Evaluating whether high-normal SUA levels, 6.8 mg/dL and below, are associated with an increased diabetes risk, compared with low-normal SUA. This was a cohort study with 10 years of followup involving all clinics of the largest nationally distributed Health Maintenance Organization in Israel. Participants included 469,947 examinees, 40-70 years old at baseline, who had their SUA measured during 2002. We excluded examinees who had hyperuricemia (SUA > 6.8 mg/dL), impaired fasting glucose, overweight or obesity and chronic cardiovascular or renal disorders. The final cohort was composed of 30 302 participants. Participants were followed up to a new diagnosis of diabetes during the study period. Odds ratio of developing diabetes among participants with high-normal baseline SUA were compared with low-normal (2 ≤ uric acid < 3 and 3 ≤ uric acid < 4 in women and men, respectively). In a logistic regression model adjusted for age, body mass index, socioeconomic status, smoking, baseline estimated glomerular filtration rate, and baseline glucose, SUA levels of 4-5 mg/dL for women were associated with 61% increased risk for incident diabetes (95% confidence interval, 1.1-2.3). At the highest normal levels for women (SUA, 5-6 mg/dL) the odds ratio was 2.7 (1.8-4.0), whereas men had comparable diabetes risk at values of 6-6.8 mg/dL (hazard ratio, 1.35; 95% confidence interval, 0.9-2.1). SUA levels within the normal range are associated with an increased risk for new-onset diabetes among healthy lean women when compared with those with low-normal values.
Solomon, Lawrence R
2016-01-01
Cobalamin (B12) deficiency can lead to irreversible neurocognitive changes if unrecognized. Screening involves measurement of serum cobalamin levels, but the sensitive metabolic indicators of cobalamin deficiency, methylmalonic acid (MMA) and homocysteine (HCys), may be normal when cobalamin values are low and elevated when cobalamin values are normal. Because cobalamin is inactivated by oxidation, the relationship between these metabolites and comorbidities associated with increased oxidative stress (oxidant risks) in subjects with low and low-normal cobalamin levels was studied. A retrospective record-review was conducted of community-dwelling adults evaluated for cobalamin deficiency during a 12-year period with serum cobalamin values in the low (≤ 200 pg/mL; n = 49) or low-normal (201-300 pg/mL; n = 187) range and concurrent measurement of MMA. When "No" oxidant risk was present, elevated MMA (>250 nmol/L) and HCys (>12.1 μmol/L) values occurred in 50% and 30% of subjects, respectively (P <.01). In contrast, when "Three or More" oxidant risks were present, mean MMA and HCys values were significantly higher, and elevated MMA and HCys values occurred in 84% and 78% of these subjects, respectively (P ≤.012). Pharmacologic doses of cyanocobalamin significantly decreased metabolite values in ≥ 94% of treated subjects. In subjects with low or low-normal cobalamin values, metabolic evidence of cobalamin deficiency is more frequent when 3 or more oxidant risks are present. Thus, defining a low serum cobalamin level to screen for cobalamin deficiency may be a "moving target" due to the variable presence and severity of often subtle, confounding clinical conditions in individual subjects. Copyright © 2016 Elsevier Inc. All rights reserved.
Blood glucose may condition factor VII levels in diabetic and normal subjects.
Ceriello, A; Giugliano, D; Quatraro, A; Dello Russo, P; Torella, R
1988-12-01
Increased factor VII levels have been reported in Type 1 (insulin-dependent) diabetic subjects. A direct correlation between fasting plasma glucose and factor VII level was found to exist in both diabetic and normal subjects. Induced-hyperglycaemia was able to increase factor VII levels in both diabetic patients and normal control subjects while, when euglycaemia was achieved in diabetic patients, factor VII values returned to normal range. This study shows that the level of factor VII may be directly conditioned by circulating blood glucose and, therefore, stresses the role of hyperglycaemia in conditioning coagulation abnormalities in diabetes mellitus.
Takeichi, M; Sato, T
1999-01-01
Computer-assisted image analyses were performed on the tongue color of 95 medical students without previous history of blood stasis-related condition to clarify the mutual relationship of the color of the tongue proper, the coating, and sublingual vein. The location of the measurement for the tongue proper was the underside of the tongue, and location of the measurement for the tongue coating was the upper surface of the tongue. A linear correlation analysis showed a correlation for each of the different positions for the non-normalized red value and normalized blue value. This analysis also demonstrated a statistically-significant relationship between the tongue proper and the sublingual vein using Red-Green-Blue components and normalized Red-Green-Blue components (r = +0.670 - 0.817, p < 0.0001). The most significant correlation between the tongue proper and the sublingual vein was the normalized red value and the normalized Red-Green-Blue values for minimizing the range of the standard error of the mean (r = +0.745, p < 0.0001), although non-normalized blue had the highest correlation coefficient. Therefore, it seems reasonable to select those normalized red values for the comparison in the tongue color analysis. Correlation of the color between the sublingual vein and the tongue proper strongly suggests that inspection with the naked eye of the sublingual vein is useful for the early detection of vital energy stagnation and blood stasis. Also, because of its close relation to sustained chronic stress, changes in the sublingual vein might be available as one physiological parameter of a stress reaction.
NASA Astrophysics Data System (ADS)
Wang, X.; Tu, C. Y.; He, J.; Wang, L.
2017-12-01
The spectrum break at the ion scale of the solar wind magnetic fluctuations are considered to give important clue on the turbulence dissipation mechanism. Among several possible mechanisms, the most notable ones are the two mechanisms that related respectively with proton thermal gyro-radius and proton inertial length. However, no definite conclusion has been given for which one is more reasonable because the two parameters have similar values in the normal plasma beta range. Here we do a statistical study for the first time to see if the two mechanism predictions have different dependence on the solar wind velocity and on the plasma beta in the normal plasma beta range in the solar wind at 1 AU. From magnetic measurements by Wind, Ulysses and Messenger, we select 60 data sets with duration longer than 8 hours. We found that the ratio between the proton inertial scale and the spectrum break scale do not change considerably with both varying the solar wind speed from 300km/s to 800km/s and varying the plasma beta from 0.2 to 1.4. The average value of the ratio times 2pi is 0.46 ± 0.08. However, the ratio between the proton gyro-radius and the break scale changes clearly. This new result shows that the proton inertial scale could be a single factor that determines the break length scale and hence gives a strong evidence to support the dissipation mechanism related to it in the normal plasma beta range. The value of the constant ratio may relate with the dissipation mechanism, but it needs further theoretical study to give detailed explanation.
Perceptual rate normalization in naturally produced bilabial stops
NASA Astrophysics Data System (ADS)
Nagao, Kyoko; de Jong, Kenneth
2003-10-01
The perception of voicing categories is affected by the speaking rate, so that listeners' category boundaries on a VOT continuum shift to a lower value when the syllable duration decreases (Miller and Volaitis, 1989; Volaitis and Miller, 1992). Previous rate normalization effects have been found using computer-generated stimuli. This study examines the effect of speech rate on voicing categorization in naturally produced speech. Four native speakers of American English repeated syllables (/bi/ and /pi/) at increasing rates in time with a metronome. Three-syllable stimuli were spliced from the repetitive speech. These stimuli contained natural decreases in VOT with faster speech rates. Besides, this rate effect on VOT was larger for /p/ than /b/, so that VOT values for /b/ and /p/ overlapped at the fastest rates. Eighteen native listeners of American English were presented with 168 stimuli and asked to identify the consonant. Perceptual category boundaries occur at VOT values 15 ms shorter than the values reported for synthesized stimuli. This difference may be due to the extraordinarily wide range of VOT values in previous studies. The values found in the current study closely match the actual division point for /b/ and /p/. The underlying mechanism of perceptual normalization will be discussed.
Nosratieh, Anita; Hernandez, Andrew; Shen, Sam Z; Yaffe, Martin J; Seibert, J Anthony; Boone, John M
2015-09-21
To develop tables of normalized glandular dose coefficients D(g)N for a range of anode-filter combinations and tube voltages used in contemporary breast imaging systems. Previously published mono-energetic D(g)N values were used with various spectra to mathematically compute D(g)N coefficients. The tungsten anode spectra from TASMICS were used; molybdenum and rhodium anode-spectra were generated using MCNPX Monte Carlo code. The spectra were filtered with various thicknesses of Al, Rh, Mo or Cu. An initial half value layer (HVL) calculation was made using the anode and filter material. A range of the HVL values was produced with the addition of small thicknesses of polymethyl methacrylate (PMMA) as a surrogate for the breast compression paddle, to produce a range of HVL values at each tube voltage. Using a spectral weighting method, D(g)N coefficients for the generated spectra were calculated for breast glandular densities of 0%, 12.5%, 25%, 37.5%, 50% and 100% for a range of compressed breast thicknesses from 3 to 8 cm. Eleven tables of normalized glandular dose (D(g)N) coefficients were produced for the following anode/filter combinations: W + 50 μm Ag, W + 500 μm Al, W + 700 μm Al, W + 200 μm Cu, W + 300 μm Cu, W + 50 μm Rh, Mo + 400 μm Cu, Mo + 30 μm Mo, Mo + 25 μm Rh, Rh + 400 μm Cu and Rh + 25 μm Rh. Where possible, these results were compared to previously published D(g)N values and were found to be on average less than 2% different than previously reported values.Over 200 pages of D(g)N coefficients were computed for modeled x-ray system spectra that are used in a number of new breast imaging applications. The reported values were found to be in excellent agreement when compared to published values.
[Objective measurement of normal nasality in the Saxony dialect].
Müller, R; Beleites, T; Hloucal, U; Kühn, M
2000-12-01
In the United States of America, the nasometer was developed by Fletcher as an objective method for measuring nasality. There are no accepted normal values for comparable test materials regarding the German language. The aim of this study was the examination of the auditively normal nasality of Saxon-speaking people with the nasometer. The nasalance of 51 healthy Saxon-speaking test persons with auditively normal nasality was measured with a model 6200 nasometer (Kay-Elemetrics, U.S.A.). The text materials used were the vowels "a", "e", "i", "o", and "u", the sentences "Die Schokolade ist sehr lecker" ("The chocolate is very tasty") and "Nenne meine Mama Mimi" ("Name my mama Mimi"), and the texts of "North wind and sun", "A children's birthday", and an arbitrary selection from Strittmatter. The mean nasalance for the vowels was 17.7%, for the sentence containing no nasal sounds 13.0%, and for the sentence containing many nasal sounds 67.2%. The mean value of the texts was 33-41%. The results for the texts agreed well with the results of Reuter (1997), who examined people from the state of Brandenburg. A range from 20% to 55% is suggested as the normal value for nasalance in the German-speaking area.
Coccidioides complement fixation
... antibodies are detected in the blood sample. Normal value ranges may vary slightly among different laboratories. Some labs use different measurements or test different samples. Talk to your health care provider about the meaning of your specific test results.
CADDIS Volume 4. Data Analysis: Basic Analyses
Use of statistical tests to determine if an observation is outside the normal range of expected values. Details of CART, regression analysis, use of quantile regression analysis, CART in causal analysis, simplifying or pruning resulting trees.
Clinical biochemistry, haematology and body weight in piglets.
Egeli, A K; Framstad, T; Morberg, H
1998-01-01
Reference ranges for clinical biochemical parameters commonly investigated in pigs were determined in one- (day 1), 21- and 35-day old piglets. The mean and standard deviation were also estimated for body weight, and haematological and clinical biochemical parameters at these ages. The piglets were divided into 2 investigation groups according to whether they had a haemoglobin concentration < or = 80 g/l ("anaemic group") or > 80 g/l ("normal group") on days 14, 21 and 28. The "anaemic group" was compared to the "normal group" on days 21 and 35. Many of the clinical biochemical parameters varied according to age. Some of the enzymes had high average values and wide reference ranges in piglets, especially on day 1, compared to the reference ranges for sows given in the literature. The reference ranges for some of the metabolic parameters were broader on day 1 than later in the preweaning period. The reference ranges for albumin, total iron-binding capacity and serum iron were, however, lower and more narrow on day 1. On days 21 and 35, relatively high values for phosphorus must be considered "normal" compared to the figures given in the literature for adult pigs. The other minerals seemed to be quite unaffected of age, but some were affected by anaemia. The anaemic piglets had lower average serum iron but higher total iron-binding capacity than the "normal" piglets on days 21 and 35. However, variation between piglets gave wide reference ranges, indicating that these parameters will only have limited usefulness in detecting iron deficiency anaemia in piglets. The electrolytes seemed also to be affected by the existence of anaemia. The body weight and leukocyte counts were significantly lower in the "anaemic group" than the "normal group" on day 35, while the greatest differences in clinical biochemical parameters between the groups were found on day 21, when the piglets in the "anaemic group" were most severely anaemic. Although these piglets suffered from severe iron-deficiency anaemia, only a few clinical biochemical parameters were affected, and the differences between groups were mostly small.
Adaptive Value Normalization in the Prefrontal Cortex Is Reduced by Memory Load
Burke, C. J.; Seifritz, E.; Tobler, P. N.
2017-01-01
Abstract Adaptation facilitates neural representation of a wide range of diverse inputs, including reward values. Adaptive value coding typically relies on contextual information either obtained from the environment or retrieved from and maintained in memory. However, it is unknown whether having to retrieve and maintain context information modulates the brain’s capacity for value adaptation. To address this issue, we measured hemodynamic responses of the prefrontal cortex (PFC) in two studies on risky decision-making. In each trial, healthy human subjects chose between a risky and a safe alternative; half of the participants had to remember the risky alternatives, whereas for the other half they were presented visually. The value of safe alternatives varied across trials. PFC responses adapted to contextual risk information, with steeper coding of safe alternative value in lower-risk contexts. Importantly, this adaptation depended on working memory load, such that response functions relating PFC activity to safe values were steeper with presented versus remembered risk. An independent second study replicated the findings of the first study and showed that similar slope reductions also arose when memory maintenance demands were increased with a secondary working memory task. Formal model comparison showed that a divisive normalization model fitted effects of both risk context and working memory demands on PFC activity better than alternative models of value adaptation, and revealed that reduced suppression of background activity was the critical parameter impairing normalization with increased memory maintenance demand. Our findings suggest that mnemonic processes can constrain normalization of neural value representations. PMID:28462394
Hoffman, Joel C; Sierszen, Michael E; Cotter, Anne M
2015-11-15
Normalizing δ(13) C values of animal tissue for lipid content is necessary to accurately interpret food-web relationships from stable isotope analysis. To reduce the effort and expense associated with chemical extraction of lipids, various studies have tested arithmetic mass balance to mathematically normalize δ(13) C values for lipid content; however, the approach assumes that lipid content is related to the tissue C:N ratio. We evaluated two commonly used models for estimating tissue lipid content based on C:N ratio (a mass balance model and a stoichiometric model) by comparing model predictions to measure the lipid content of white muscle tissue. We then determined the effect of lipid model choice on δ(13) C values normalized using arithmetic mass balance. To do so, we used a collection of fish from Lake Superior spanning a wide range in lipid content (5% to 73% lipid). We found that the lipid content was positively related to the bulk muscle tissue C:N ratio. The two different lipid models produced similar estimates of lipid content based on tissue C:N, within 6% for tissue C:N values <7. Normalizing δ(13) C values using an arithmetic mass-balance equation based on either model yielded similar results, with a small bias (<1‰) compared with results based on chemical extraction. Among-species consistency in the relationship between fish muscle tissue C:N ratio and lipid content supports the application of arithmetic mass balance to normalize δ(13) C values for lipid content. The uncertainty associated with both lipid extraction quality and choice of model parameters constrains the achievable precision of normalized δ(13) C values to about ±1.0‰. Published in 2015. This article is a U.S. Government work and is in the public domain in the U.S.A.
Capron, Florent; Alla, Francois; Hottier, Claire; Meistelman, Claude; Fuchs-Buder, Thomas
2004-05-01
The incidence of residual paralysis, i.e., a mechanomyographic train-of-four (TOF) ratio (T4/T1) less than 0.9, remains frequent. Routine acceleromyography has been proposed to detect residual paralysis in clinical practice. Although acceleromyographic data are easy to obtain, they differ from mechanomyographic data, with which they are not interchangeable. The current study aimed to determine (1) the acceleromyographic TOF ratio that detects residual paralysis with a 95% probability, and (2) the impact of calibration and normalization on this predictive acceleromyographic value. In 60 patients, recovery from neuromuscular block was assessed simultaneously with mechanomyography and acceleromyography. To obtain calibrated acceleromyographic TOF ratios in group A, the implemented calibration modus 2 was activated in the TOF-Watch S; to obtain uncalibrated acceleromyographic TOF ratios in group B, the current was manually set at 50 mA (n = 30 for each). In addition, data in group B were normalized (i.e., dividing the final TOF ratio by the baseline value). The agreement between mechanomyography and acceleromyography was assessed by calculating the intraclass correlation coefficient. Negative predictive values were calculated for detecting residual paralysis from acceleromyographic TOFs of 0.9, 0.95, and 1.0. : For a mechanomyographic TOF of 0.9 or greater, the corresponding acceleromyographic TOF was 0.95 (range, 0.86-1.0), and the negative predictive values for acceleromyographic TOFs of 0.9, 0.95, and 1.0 were 37% (95% CI, 20-56%), 70% (95% CI, 51-85%), and 97% (95% CI, 83-100%), respectively. Group B: Without normalization, an acceleromyographic TOF of 0.97 (range, 0.68-1.18) corresponded to a mechanomyographic TOF of 0.9 or greater, with negative predictive values for acceleromyographic TOFs of 0.9, 0.95, and 1.0 being 40% (95% CI, 23-59%), 60% (95% CI, 41-77%), and 77% (95% CI, 58-90%), respectively. After normalization, an acceleromyographic TOF of 0.89 (range, 0.63-1.06) corresponded to a mechanomyographic TOF of 0.9 or greater, and the negative predictive values of acceleromyographic TOFs of 0.9, 0.95, and 1.0 were 89% (95% CI, 70-98%), 92% (95% CI, 75-99%), and 96% (95% CI, 80-100%), respectively. To exclude residual paralysis reliably when using acceleromyography, TOF recovery to 1.0 is mandatory.
Zikmund-Fisher, Brian J; Scherer, Aaron M; Witteman, Holly O; Solomon, Jacob B; Exe, Nicole L; Fagerlin, Angela
2018-03-26
Patient-facing displays of laboratory test results typically provide patients with one reference point (the "standard range"). To test the effect of including an additional harm anchor reference point in visual displays of laboratory test results, which indicates how far outside of the standard range values would need to be in order to suggest substantial patient risk. Using a demographically diverse, online sample, we compared the reactions of 1618 adults in the United States who viewed visual line displays that included both standard range and harm anchor reference points ("Many doctors are not concerned until here") to displays that included either (1) only a standard range, (2) standard range plus evaluative categories (eg, "borderline high"), or (3) a color gradient showing degree of deviation from the standard range. Providing the harm anchor reference point significantly reduced perceived urgency of close-to-normal alanine aminotransferase and creatinine results (P values <.001) but not generally for platelet count results. Notably, display type did not significantly alter perceptions of more extreme results in potentially harmful ranges. Harm anchors also substantially reduced the number of participants who wanted to contact their doctor urgently or go to the hospital about these test results. Presenting patients with evaluative cues regarding when test results become clinically concerning can reduce the perceived urgency of out-of-range results that do not require immediate clinical action. ©Brian J Zikmund-Fisher, Aaron M Scherer, Holly O Witteman, Jacob B Solomon, Nicole L Exe, Angela Fagerlin. Originally published in the Journal of Medical Internet Research (http://www.jmir.org), 26.03.2018.
CMV antibody tests ... never been infected with CMV have no detectable antibodies to CMV. Normal value ranges may vary slightly ... The presence of antibodies to CMV indicates a current or past ... CMV. If the number of antibodies (called the antibody titer) ...
Wada, Yumiko; Furuse, Tamio; Yamada, Ikuko; Masuya, Hiroshi; Kushida, Tomoko; Shibukawa, Yoko; Nakai, Yuji; Kobayashi, Kimio; Kaneda, Hideki; Gondo, Yoichi; Noda, Tetsuo; Shiroishi, Toshihiko; Wakana, Shigeharu
2010-01-01
To establish the cutoff values for screening ENU-induced behavioral mutations, normal variations in mouse behavioral data were examined in home-cage activity (HA), open-field (OF), and passive-avoidance (PA) tests. We defined the normal range as one that included more than 95% of the normal control values. The cutoffs were defined to identify outliers yielding values that deviated from the normal by less than 5% for C57BL/6J, DBA/2J, DBF(1), and N(2) (DXDB) progenies. Cutoff values for G1-phenodeviant (DBF(1)) identification were defined based on values over +/- 3.0 SD from the mean of DBF(1) for all parameters assessed in the HA and OF tests. For the PA test, the cutoff values were defined based on whether the mice met the learning criterion during the 2nd (at a shock intensity of 0.3 mA) or the 3rd (at a shock intensity of 0.15 mA) retention test. For several parameters, the lower outliers were undetectable as the calculated cutoffs were negative values. Based on the cutoff criteria, we identified 275 behavioral phenodeviants among 2,646 G1 progeny. Of these, 64 were crossed with wild-type DBA/2J individuals, and the phenotype transmission was examined in the G2 progeny using the cutoffs defined for N(2) mice. In the G2 mice, we identified 15 novel dominant mutants exhibiting behavioral abnormalities, including hyperactivity in the HA or OF tests, hypoactivity in the OF test, and PA deficits. Genetic and detailed behavioral analysis of these ENU-induced mutants will provide novel insights into the molecular mechanisms underlying behavior.
Jin, Jonghwa; Park, Jiyoung; Yu, Su Jong; Yoon, Jung-Hwan; Kim, Youngsoo
2014-01-01
Serum alpha-fetoprotein (AFP) has long been used as a diagnostic marker for hepatocellular carcinoma (HCC), albeit controversially. Although it remains widely used in clinics, the value of AFP in HCC diagnosis has recently been challenged due to its significant rates of false positive and false negative findings. To improve the efficacy of AFP as HCC diagnostic marker, we developed a method of measuring total and glycosylated AFP by multiple reaction monitoring (MRM)-MS. In this study, we verified the total amount of AFP (nonglycopeptide levels) and the degree of glycosylated AFP (deglycopeptide levels) in 60 normal (41 men and 19 women; mean age 53 years; range 32–74 years), 35 LC (23 men and 12 women; mean age 56 years; range 43–78 years; HBV-related), and 60 HCC subjects (42 men and 18 women; mean age 58 years; range 38–76 years; HBV-related; 30 stage I, 15 stage II, and 10 stage III). By MRM-MS analysis, the nonglycopeptide had 56.7% sensitivity, 68.3% specificity, and an AUC of 0.687 [cutoff value: ≥0.02 (light/heavy ratio)], comparing the normal and HCC group, whereas the deglycopeptide had 93.3% sensitivity, 68.3% specificity, and an AUC of 0.859 [cutoff value: ≥0.02 (light/heavy ratio)]. In comparing the stage I HCC subgroup with the LC group, the nonglycopeptide had a sensitivity of 66.7%, specificity of 80.0%, and an AUC of 0.712 [cutoff value: ≥0.02 (light/heavy ratio)], whereas the deglycopeptide had a sensitivity of 96.7%, specificity of 80.0%, and an AUC of 0.918 [cutoff value: ≥0.02 (light/heavy ratio)]. These data demonstrate that the discriminatory power of the deglycopeptide is greater than that of the nonglycopeptide. We conclude that deglycopeptide can distinguish cancer status between normal subjects and HCC patients better than nonglycopeptide. PMID:25310463
Reliability of provocative tests of motion sickness susceptibility
NASA Technical Reports Server (NTRS)
Calkins, D. S.; Reschke, M. F.; Kennedy, R. S.; Dunlop, W. P.
1987-01-01
Test-retest reliability values were derived from motion sickness susceptibility scores obtained from two successive exposures to each of three tests: (1) Coriolis sickness sensitivity test; (2) staircase velocity movement test; and (3) parabolic flight static chair test. The reliability of the three tests ranged from 0.70 to 0.88. Normalizing values from predictors with skewed distributions improved the reliability.
Integral luminosities of radio pulsars
NASA Astrophysics Data System (ADS)
Malov, I.; Malov, O.
The integral radio luminosities L for 311 normal pulsars and for 27 ones with the rotation period P<0.1 s (fast pulsars) are calculated using new data on their compilated spectra. The values of L lie in the range 10^27-10^30 erg/s for 88% of the normal pulsars and in the range 10^28-10^31 erg/s for 88% of the fast objects. The high correlation between L and estimates l=S x d^2 from the known catalogues is detected. It is shown that the coefficient K of a transformation of the neutron star rotation energy into radio emission increases when P grows for normal pulsars and falls for fast ones. The mean values of K are -3.73 and -4.85 for normal and fast pulsars, respectively. There are no changes of L with the kinematic age T = z/V, where z is the pulsar height over the Galactic plane and V = 300 km/s is its mean velocity. The correlation between L and the rate of the rotation energy losses E is detected for both pulsar groups under consideration. It is shown that L= A E^(1/3) for the whole sample. The total number of pulsars in the Galaxy and their birth rate are in agreement with data on the rate of supernova explosions.
Broughton, Heather M; Govender, Danny; Shikwambana, Purvance; Chappell, Patrick; Jolles, Anna
2017-06-01
The International Species Information System has set forth an extensive database of reference intervals for zoologic species, allowing veterinarians and game park officials to distinguish normal health parameters from underlying disease processes in captive wildlife. However, several recent studies comparing reference values from captive and free-ranging animals have found significant variation between populations, necessitating the development of separate reference intervals in free-ranging wildlife to aid in the interpretation of health data. Thus, this study characterizes reference intervals for six biochemical analytes, eleven hematologic or immune parameters, and three hormones using samples from 219 free-ranging African lions ( Panthera leo ) captured in Kruger National Park, South Africa. Using the original sample population, exclusion criteria based on physical examination were applied to yield a final reference population of 52 clinically normal lions. Reference intervals were then generated via 90% confidence intervals on log-transformed data using parametric bootstrapping techniques. In addition to the generation of reference intervals, linear mixed-effect models and generalized linear mixed-effect models were used to model associations of each focal parameter with the following independent variables: age, sex, and body condition score. Age and sex were statistically significant drivers for changes in hepatic enzymes, renal values, hematologic parameters, and leptin, a hormone related to body fat stores. Body condition was positively correlated with changes in monocyte counts. Given the large variation in reference values taken from captive versus free-ranging lions, it is our hope that this study will serve as a baseline for future clinical evaluations and biomedical research targeting free-ranging African lions.
Normal values for segmental bioimpedance spectroscopy in pediatric patients.
Avila, Maria Laura; Ward, Leigh C; Feldman, Brian M; Montoya, Madeline I; Stinson, Jennifer; Kiss, Alex; Brandão, Leonardo R
2015-01-01
Localized limb edema is a clinically relevant sign in diseases such as post-thrombotic syndrome and lymphedema. Quantitative evaluation of localized edema in children is mainly done by measuring the absolute difference in limb circumference, which includes fat and fat-free mass. Bioimpedance spectroscopy (BIS) provides information on the fluid volume of a body segment. Our objective was to determine normal ranges for segmental (arm and leg) BIS measurements in healthy children. Additionally, we determined the normal ranges for the difference in arm and ankle circumference and explored the influence of handedness and the correlation between techniques. Healthy children aged 1-18 years were recruited. The ratio of extracellular fluid content between contralateral limbs (estimated as the inter-arm and inter-leg extracellular impedance ratio), and the ratio of extracellular to intracellular fluid content for each limb (estimated as the intracellular to extracellular impedance ratio) were determined with a bioimpedance spectrometer. Arm and ankle circumference was determined with a Gulick II tape. We recruited 223 healthy children (48 infants, 54 preschoolers, 66 school-aged children, and 55 teenagers). Normal values for arm and leg BIS measurements, and for the difference in arm and ankle circumference were estimated for each age category. No influence of handedness was found. We found a statistically significant correlation between extracellular impedance ratio and circumference difference for arms among teenagers. We determined normal BIS ranges for arms and legs and for the difference in circumference between arms and between ankles in children. There was no statistically significant correlation between extracellular impedance ratio and difference in circumference, except in the case of arms in adolescents. This may indicate that limb circumference measures quantities other than fluid, challenging the adequacy of this technique to determine the presence of localized edema in most age groups.
Mean Glandular dose coefficients (DgN) for x-ray spectra used in contemporary breast imaging systems
Nosratieh, Anita; Hernandez, Andrew; Shen, Sam Z.; Yaffe, Martin J.; Seibert, J. Anthony; Boone, John M.
2015-01-01
Purpose To develop tables of normalized glandular dose coefficients DgN for a range of anode–filter combinations and tube voltages used in contemporary breast imaging systems. Methods Previously published mono-energetic DgN values were used with various spectra to mathematically compute DgN coefficients. The tungsten anode spectra from TASMICS were used; Molybdenum and Rhodium anode-spectra were generated using MCNPx Monte Carlo code. The spectra were filtered with various thicknesses of Al, Rh, Mo or Cu. An initial HVL calculation was made using the anode and filter material. A range of the HVL values was produced with the addition of small thicknesses of polymethyl methacrylate (PMMA) as a surrogate for the breast compression paddle, to produce a range of HVL values at each tube voltage. Using a spectral weighting method, DgN coefficients for the generated spectra were calculated for breast glandular densities of 0%, 12.5%, 25%, 37.5%, 50% and 100% for a range of compressed breast thicknesses from 3 to 8 cm. Results Eleven tables of normalized glandular dose (DgN) coefficients were produced for the following anode/filter combinations: W + 50 μm Ag, W + 500 μm Al, W + 700 μm Al, W + 200 μm Cu, W + 300 μm Cu, W + 50 μm Rh, Mo + 400 μm Cu, Mo + 30 μm Mo, Mo + 25 μm Rh, Rh + 400 μm Cu and Rh + 25 μm Rh. Where possible, these results were compared to previously published DgN values and were found to be on average less than 2% different than previously reported values. Conclusion Over 200-pages of DgN coefficients were computed for modeled x-ray system spectra that are used in a number of new breast imaging applications. The reported values were found to be in excellent agreement when compared to published values. PMID:26348995
Francart, Suzanne J; Hawes, Emily M; Deal, Allison M; Adcock, Dorothy M; Gosselin, Robert; Jeanneret, Cheryl; Friedman, Kenneth D; Moll, Stephan
2014-06-01
Knowledge of anticoagulation status during rivaroxaban therapy is desirable in certain clinical situations. It was the study objective to determine coagulation tests most useful for assessing rivaroxaban's anticoagulant effect. Peak and trough blood samples from 29 patients taking rivaroxaban 20 mg daily were collected. Mass spectrometry and various coagulation assays were performed. "On-therapy range" was defined as the rivaroxaban concentrations determined by LC-MS/MS. A "misprediction percentage" was calculated based on how often results of each coagulation assay were in the normal reference range, while the rivaroxaban concentration was in the "on-therapy" range. The on-therapy range was 8.9-660 ng/ml. The misprediction percentages for prothrombin time (PT) and activated partial thromboplastin time (aPTT), using multiple reagents and coagulometers, ranged from 10%-52% and 31%-59%, respectively. PT, aPTT and activated clotting time (ACT) were insensitive to trough rivaroxaban: 59%, 62%, and 80% of samples had a normal result, respectively. Over 95% of PT and ACT values were elevated at peak. Four different rivaroxaban calibrated anti-Xa assays had R² values >0.98, demonstrating strong correlations with rivaroxaban drug levels. In conclusion, PT, aPTT and ACT are often normal in patients on therapeutic doses of rivaroxaban. However, PT and ACT may have clinical utility at higher drug plasma levels. Rivaroxaban calibrated anti-factor Xa assays can accurately identify low and high on-therapy rivaroxaban drug levels and, therefore, have superior utility in all clinical situations where assessment of anticoagulation status may be beneficial.
Hobbs, Robert F; Wahl, Richard L; Frey, Eric C; Kasamon, Yvette; Song, Hong; Huang, Peng; Jones, Richard J; Sgouros, George
2014-01-01
Combination treatment is a hallmark of cancer therapy. Although the rationale for combination radiopharmaceutical therapy was described in the mid ‘90s, such treatment strategies have only been implemented clinically recently, and without a rigorous methodology for treatment optimization. Radiobiological and quantitative imaging-based dosimetry tools are now available that enable rational implementation of combined targeted radiopharmaceutical therapy. Optimal implementation should simultaneously account for radiobiological normal organ tolerance while optimizing the ratio of two different radiopharmaceuticals required to maximize tumor control. We have developed such a methodology and applied it to hypothetical myeloablative treatment of non-hodgkin’s lymphoma (NHL) patients using 131I-tositumomab and 90Y-ibritumomab tiuxetan. Methods The range of potential administered activities (AA) is limited by the normal organ maximum tolerated biologic effective doses (MTBEDs) arising from the combined radiopharmaceuticals. Dose limiting normal organs are expected to be the lungs for 131I-tositumomab and the liver for 90Y-ibritumomab tiuxetan in myeloablative NHL treatment regimens. By plotting the limiting normal organ constraints as a function of the AAs and calculating tumor biological effective dose (BED) along the normal organ MTBED limits, the optimal combination of activities is obtained. The model was tested using previously acquired patient normal organ and tumor kinetic data and MTBED values taken from the literature. Results The average AA values based solely on normal organ constraints was (19.0 ± 8.2) GBq with a range of 3.9 – 36.9 GBq for 131I-tositumomab, and (2.77 ± 1.64) GBq with a range of 0.42 – 7.54 GBq for 90Y-ibritumomab tiuxetan. Tumor BED optimization results were calculated and plotted as a function of AA for 5 different cases, established using patient normal organ kinetics for the two radiopharmaceuticals. Results included AA ranges which would deliver 95 % of the maximum tumor BED, which allows for informed inclusion of clinical considerations, such as a maximum allowable 131I administration. Conclusions A rational approach for combination radiopharmaceutical treatment has been developed within the framework of a proven 3-dimensional personalized dosimetry software, 3D-RD, and applied to the myeloablative treatment of NHL. We anticipate combined radioisotope therapy will ultimately supplant single radioisotope therapy, much as combination chemotherapy has substantially replaced single agent chemotherapy. PMID:23918734
Normal-pressure Tests of Circular Plates with Clamped Edges
NASA Technical Reports Server (NTRS)
Mcpherson, Albert E; Ramberg, Walter; Levy, Samuel
1942-01-01
A fixture is described for making normal-pressure tests of flat plates 5 inches in diameter in which particular care was taken to obtain rigid clamping at the edges. Results are given for 19 plates, ranging in thickness from 0.015 to 0.072 inch. The center deflections and the extreme-fiber stresses at low pressures were found to agree with theoretical values; the center deflections at high pressures were 4 to 12 percent greater than the theoretical values. Empirical curves are derived of the pressure for the beginning of permanent set as a function of the dimensions of the plate and the tensile properties of the material.
Normal-Pressure Tests of Circular Plates with Clamped Edges
NASA Technical Reports Server (NTRS)
Mcpherson, Albert E; Ramberg, Walter; Levy, Samuel
1942-01-01
A fixture is described for making normal-pressure tests of flat plates 5 inches in diameter in which particular care was taken to obtain rigid clamping at the edges. Results are given for 19 plates, ranging in thickness form 0.015 to 0.072 inch. The center deflections and the extreme-fiber stresses at low pressures were found to agree with theoretical values; the center deflections at high pressures were 4 to 12 percent greater than the theoretical values. Empirical curves are derived of the pressure for the beginning of the permanent set as a function of the dimensions of the plate and the tensile properties of the material.
Some blood chemistry values for the Rainbow Trout (Salmo gairdneri)
Wedemeyer, Gary; Chatterton, K.
1970-01-01
Normal distribution curves were graphically fitted to approximately 1400 clinical test values obtained from the plasma or kidney tissue of more than 200 yearling rainbow trout (Salmo gairdneri). Estimated normal ranges were ascorbate, 102–214 μg/g; blood urea nitrogen (BUN), 0.9–4.5 mg/100 ml; chloride, 84–132 mEq/liter; cholesterol, 161–365 mg/100 ml; cortisol, 1.5–18.5 μg/100 ml; glucose, 41–151 mg/100 ml; and total protein, 2–6 g/100 ml.
Budelmann, Kim; von Piekartz, Harry; Hall, Toby
2016-09-01
Cervical movement impairment has been identified as a core component of cervicogenic headache evaluation. However, normal range of motion values in children has been investigated rarely and no study has reported such values for the flexion-rotation test (FRT). The purpose of this study was to identify normal values and side-to-side variation for cervical spine range of motion (ROM) and the FRT, in asymptomatic children aged 6-12 years. Another important purpose was to identify the presence of pain during the FRT. Thirty-four asymptomatic children without history of neck pain or headache (26 females and 8 males, mean age 125.38 months [SD 13.14]) were evaluated. Cervical spine cardinal plane ROM and the FRT were evaluated by a single examiner using a cervical ROM device. Values for cardinal plane ROM measures are presented. No significant gender difference was found for any ROM measure. Mean difference in ROM for rotation, side flexion, and the FRT were less than one degree. However, intra-individual variation was greater, with lower bound scores of 9.32° for rotation, 5.30° for side flexion, and 10.89° for the FRT. Multiple linear regression analysis indicates that movement in the cardinal planes only explains 19% of the variance in the FRT. Pain scores reported following the FRT were less than 2/10. Children have consistently greater cervical spine ROM than adults. In children, side-to-side variation in rotation and side flexion ROM and range recorded during the FRT indicates that the clinician should be cautious when using range in one direction to determine impairment in another. Range recorded during the FRT is independent of cardinal movement variables, which further adds to the importance of the FRT, as a test that mainly evaluates range of movement of the upper cervical spine.
Rhee, Sun Jung; Hong, Hyun Sook; Kim, Chul-Hee; Lee, Eun Hye; Cha, Jang Gyu; Jeong, Sun Hye
2015-12-01
This study aimed to evaluate the usefulness of Acoustic Structure Quantification (ASQ; Toshiba Medical Systems Corporation, Nasushiobara, Japan) values in the diagnosis of Hashimoto thyroiditis using B-mode sonography and to identify a cutoff ASQ level that differentiates Hashimoto thyroiditis from normal thyroid tissue. A total of 186 thyroid lobes with Hashimoto thyroiditis and normal thyroid glands underwent sonography with ASQ imaging. The quantitative results were reported in an echo amplitude analysis (Cm(2)) histogram with average, mode, ratio, standard deviation, blue mode, and blue average values. Receiver operating characteristic curve analysis was performed to assess the diagnostic ability of the ASQ values in differentiating Hashimoto thyroiditis from normal thyroid tissue. Intraclass correlation coefficients of the ASQ values were obtained between 2 observers. Of the 186 thyroid lobes, 103 (55%) had Hashimoto thyroiditis, and 83 (45%) were normal. There was a significant difference between the ASQ values of Hashimoto thyroiditis glands and those of normal glands (P < .001). The ASQ values in patients with Hashimoto thyroiditis were significantly greater than those in patients with normal thyroid glands. The areas under the receiver operating characteristic curves for the ratio, blue average, average, blue mode, mode, and standard deviation were: 0.936, 0.902, 0.893, 0.855, 0.846, and 0.842, respectively. The ratio cutoff value of 0.27 offered the best diagnostic performance, with sensitivity of 87.38% and specificity of 95.18%. The intraclass correlation coefficients ranged from 0.86 to 0.94, which indicated substantial agreement between the observers. Acoustic Structure Quantification is a useful and promising sonographic method for diagnosing Hashimoto thyroiditis. Not only could it be a helpful tool for quantifying thyroid echogenicity, but it also would be useful for diagnosis of Hashimoto thyroiditis. © 2015 by the American Institute of Ultrasound in Medicine.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Muller, L; Soldner, A; Kirk, M
Purpose: The beam range uncertainty presents a special challenge for proton therapy. Novel technologies currently under development offer strategies to reduce the range uncertainty [1,2]. This work quantifies the potential advantages that could be realized by such a reduction for dosimetrically challenging chordomas at the base of skull. Therapeutic improvement was assessed by evaluating tumor control probabilities (TCP) and normal tissue complication probabilities (NTCP). Methods: Treatment plans were made for a modulated-scanned proton delivery technique using the Eclipse treatment planning system. The prescription dose was 7920 cGy to the CTV. Three different range uncertainty scenarios were considered: 5 mm (3.5%more » of the beam range + 1 mm, representing current clinical practice, “Curr”), 2 mm (1.3%), and 1 mm (0.7%). For each of 4 patients, 3 different PTVs were defined via uniform expansion of the CTV by the value of the range uncertainty. Tumor control probability (TCP) and normal tissue complication probabilities (NTCPs) for organs-at-risk (OARs) were calculated using the Lyman-Kutcher-Burman[3] formalism and published model parameters [ref Terahara[4], quantec S10, Burman Red Journal v21 pp 123]. Our plan optimization strategy was to achieve PTV close to prescription while maintaining OAR NTCP values at or better than the Curr plan. Results: The average TCP values for the 5, 2, and 1 mm range uncertainty scenarios are 51%, 55% and 65%. The improvement in TCP for patients was between 4 and 30%, depending primarily on the proximity of the GTV to OAR. The average NTCPs for the brainstem and cord were about 4% and 1%, respectively, for all target margins. Conclusion: For base of skull chordomas, reduced target margins can substantially increase the TCP without increasing the NTCP. This work demonstrates the potential significance of a reduction in the range uncertainty for proton beams.« less
NASA Astrophysics Data System (ADS)
Khan, Mohammad Khurram
The Monte-Carlo based simulation environment for radiation therapy (SERA) software is used to simulate the dose administered to a patient undergoing boron neutron capture therapy (BNCT). Point sampling of tumor tissue results in an estimate of a uniform boron concentration scaling factor of 3.5. Under conventional treatment protocols, this factor is used to scale the boron component of the dose linearly and homogenously within the tumor and target volumes. The average dose to the tumor cells by such a method could be improved by better methods of quantifying the in-vivo 10B biodistribution. A better method includes radiolabeling para-Boronophenylalanine (p-BPA) with 18F and imaging the pharmaceutical using positron emission tomography (PET). This biodistribution of 18F-BPA can then be used to better predict the average dose delivered to the tumor regions. This work uses registered 18F-BPA PET images to incorporate the in-vivo boron biodistribution within current treatment planning. The registered 18F-BPA PET images are then coupled in a new computer software, PET2MRI.m, to linearly scale the boron component of the dose. A qualititative and quantitative assessment of the dose contours is presented using the two approaches. Tumor volume, tumor axial extent, and target locations are compared between using MRI or PET images to define the tumor volume. In addition, peak-to-normal brain value at tumor axial center is determined for pre and post surgery patients using 18F-BPA PET images. The differences noted between the registered GBM tumor volumes (range: 34.04--136.36%), tumor axial extent (range: 20--150%), and the beam target location (1.27--4.29 cm) are significantly different. The peak-to-normal brain values are also determined at the tumor axial center using the 18F-BPA PET images. The peak-to-normal brain values using the last frame of the pre-surgery study for the GBM patients ranged from 2.05--3.4. For post surgery time weighted PET data, the peak-to-normal brain value in the residual parts of the tumor ranged from 1.5--1.7. Qualitatively, boron dose contours are greatly shifted using PET images when compared with MRI images. Collectively, these differences can lead to significant reorientation of the beam and can significantly impact current BNCT treatment planning.
Elementary solutions of coupled model equations in the kinetic theory of gases
NASA Technical Reports Server (NTRS)
Kriese, J. T.; Siewert, C. E.; Chang, T. S.
1974-01-01
The method of elementary solutions is employed to solve two coupled integrodifferential equations sufficient for determining temperature-density effects in a linearized BGK model in the kinetic theory of gases. Full-range completeness and orthogonality theorems are proved for the developed normal modes and the infinite-medium Green's function is constructed as an illustration of the full-range formalism. The appropriate homogeneous matrix Riemann problem is discussed, and half-range completeness and orthogonality theorems are proved for a certain subset of the normal modes. The required existence and uniqueness theorems relevant to the H matrix, basic to the half-range analysis, are proved, and an accurate and efficient computational method is discussed. The half-space temperature-slip problem is solved analytically, and a highly accurate value of the temperature-slip coefficient is reported.
Site index, height growth, normal yields and stocking levels for larch in Oregon and Washington.
P.H. Cochran
1985-01-01
Even-aged stands of larch in Oregon and Washington have cubic volume yields similar to yields from larch in Idaho and Montana. Site index values derived from the heights of the single tallest tree on 1/5-acre plots at an age at breast height of 50 years range from 50 to 110 feet. These values have the same index to productivity as the site index values of 30 to 90 feet...
Can overt diabetes mellitus be predicted by an early A1C value in gestational diabetics?
Granada, Catalina; Forbes, Joanna; Sangi-Haghpeykar, Haleh; Davidson, Christina
2014-01-01
To test the hypothesis that a hemoglobin A1C value (A1C) in early pregnancy is predictive of overt diabetes mellitus (DM) postpartum in women with gestational diabetes (GDM). In this case-control analysis of women with an early pregnancy diagnosis of GDM, we estimated the association between an early pregnancy A1C and subsequent diagnosis of DM. Women with a normal postpartum diabetic screen (controls) were compared against those with confirmed postpartum DM (cases). Ability of A1C levels to predict DM was examined via logistic regression analysis and corresponding receiver operating characteristic values. During the 10-year study period 166 women met the inclusion criteria: 140 (84%) had normal postpartum testing (controls), and 26 (16%) were diagnosed with DM (cases). The mean A1C value was significantly higher among cases than controls (6.7 vs. 5.6, p < 0.0001, SD 1.3-5). Cases had A1Cs ranging from 5.5- 11.7%, while controls had A1Cs ranging from 4.3-7.8%. The best discriminatory cut point for postpartum DM was an A1C > 5.9% (sensitivity 81%, specificity 83%, positive predictive value 47%, negative predictive value Our findings suggest that an elevated early pregnancy A1C may be predictive of overt DM. Larger studies are needed to further validate this association.
Euthyroid ''thyroxine toxicosis''
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mankikar, G.D.; Clark, A.N.
A survey was made of thyroid function tests on 1,153 patients screened for thyroid disease during a two-year period in a Geriatric Department; 13 percent of the test results fell outside the normal range. Of 88 patients who showed above-normal results, only 12 presented with clinical features of thyrotoxicosis. In 37 patients, the biochemical findings indicated euthyroid ''thyroxine toxicosis''; high values were found for serum thyroxine (T4) and the free thyroxine index (FT4I) but there were no clinical signs or symptoms of thyrotoxicosis; the values reverted to normal within one to three weeks. This pattern was seen also in 7more » examples of T4-treated hypothyroidism. (Overall, the test findings indicated 61 cases of hypothyroidism.) The significance of this transient increase in T4 and FT4I values is discussed. The false positive results suggest that, when laboratory findings are not compatible with the clinical signs, the thyroid function tests should be repeated after another two weeks.« less
Nelson, Winnie W; Wang, Li; Baser, Onur; Damaraju, C V; Schein, Jeffrey R
2015-05-01
Patients with out-of-range international normalized ratio (INR) values <2.0 and >3.0 have been associated with increased risk of thromboembolic and bleeding events. INR monitoring is costly, because of associated physician and nurse time, laboratory resource use, and dose adjustments. This study assessed the healthcare cost burden associated with out-of-range INR among warfarin initiator patients diagnosed with non-valvular atrial fibrillation (NVAF) in the US Veterans Health Administration (VHA) population. Adult NVAF patients (≥18 years) initiating warfarin were selected from the VHA dataset for the study period October 1, 2007-September 30, 2012. Only valid INR measurements (0.5 ≤ INR ≤ 20) were examined for the follow-up period, from the index date (warfarin initiation date) until the end of warfarin exposure or death. All-cause healthcare costs within 30 days were measured starting from the second month (31 days post-index date) to the end of the study period. Costs for inpatient stays, emergency room, outpatient facility, physician office visits, and other services were computed separately. Multiple regression was performed using the generalized linear model for overall cost analysis. In total, 29,463 patients were included in the study sample. Mean costs for out-of-range INR ranged from $3419 to $5126. Inpatient, outpatient, outpatient pharmacy, and total costs were significantly higher after patients experienced out-of-range results (INR < 2, INR > 3), compared with in-range INR (2 ≤ INR ≤ 3). When exposed to out-of-range INR, patients also incurred higher mean total costs within 2-6 months ($3840-$5820) than after the first 6 months ($2789-$3503) of warfarin therapy. In the VHA population, INR measures outside of the 2-3 range were associated with significantly higher healthcare costs. Increased costs were especially apparent when INR values were below 2, although INR measures above 3 were also associated with higher costs relative to in-range values.
NASA Technical Reports Server (NTRS)
Sawyer, J. W.; Waters, W. A., Jr.
1981-01-01
Tests were conducted at room temperature to determine the shear properties of the strain isolator pad (SIP) material used in the thermal protection system of the space shuttle. Tests were conducted on both the .23 cm and .41 cm thick SIP material in the virgin state and after fifty fully reversed shear cycles. The shear stress displacement relationships are highly nonlinear, exhibit large hysteresis effects, are dependent on material orientation, and have a large low modulus region near the zero stress level where small changes in stress can result in large displacements. The values at the higher stress levels generally increase with normal and shear force load conditioning. Normal forces applied during the shear tests reduces the low modulus region for the material. Shear test techniques which restrict the normal movement of the material give erroneous stress displacement results. However, small normal forces do not significantly effect the shear modulus for a given shear stress. Poisson's ratio values for the material are within the range of values for many common materials. The values are not constant but vary as a function of the stress level and the previous stress history of the material. Ultimate shear strengths of the .23 cm thick SIP are significantly higher than those obtained for the .41 cm thick SIP.
Real-gas effects associated with one-dimensional transonic flow of cryogenic nitrogen
NASA Technical Reports Server (NTRS)
Adcock, J. B.
1976-01-01
Real gas solutions for one-dimensional isentropic and normal-shock flows of nitrogen were obtained for a wide range of temperatures and pressures. These calculations are compared to ideal gas solutions and are presented in tables. For temperatures (300 K and below) and pressures (1 to 10 atm) that cover those anticipated for transonic cryogenic tunnels, the solutions are analyzed to obtain indications of the magnitude of inviscid flow simulation errors. For these ranges, the maximum deviation of the various isentropic and normal shock parameters from the ideal values is about 1 percent or less, and for most wind tunnel investigations this deviation would be insignificant.
Pottel, Hans; Hoste, Liesbeth; Delanaye, Pierre
2015-05-01
The chronic kidney disease (CKD) classification system for children is similar to that for adults, with both mainly based on estimated glomerular filtration rate (eGFR) combined with fixed cut-off values. The main cut-off eGFR value used to define CKD is 60 mL/min/1.73 m(2), a value that is also applied for children older than 2 years of age, adolescents and young adults. Based on a literature search, we evaluated inclusion criteria for eGFR in clinical trials or research studies on CKD for children. We also collected information on direct measurements of GFR (mGFR) in children and adolescents, with the aim to estimate the normal reference range for GFR. Using serum creatinine (Scr) normal reference values and Scr-based eGFR-equations, we also evaluated the correspondence between Scr normal reference values and (e)GFR normal reference values. Based on our literature search, the inclusion of children in published CKD studies has been based on cut-off values for eGFR of >60 mL/min/1.73 m(2). The lower reference limits for mGFR far exceed this adult threshold. Using eGFR values calculated using Scr-based formulas, we found that abnormal Scr levels in children already correspond to eGFR values that are below a cut-off of 75 mL/min/1.73 m(2). Abnormal GFR in children, adolescents and young adults starts below 75 mL/min/1.73 m(2), and as abnormality is a sign of disease, we recommend referring children, adolescents and young adults with an (e)GFR of <75 mL/min/1.73 m(2) for further clinical assessment.
Sun, Xiaofei; Shi, Lin; Luo, Yishan; Yang, Wei; Li, Hongpeng; Liang, Peipeng; Li, Kuncheng; Mok, Vincent C T; Chu, Winnie C W; Wang, Defeng
2015-07-28
Intensity normalization is an important preprocessing step in brain magnetic resonance image (MRI) analysis. During MR image acquisition, different scanners or parameters would be used for scanning different subjects or the same subject at a different time, which may result in large intensity variations. This intensity variation will greatly undermine the performance of subsequent MRI processing and population analysis, such as image registration, segmentation, and tissue volume measurement. In this work, we proposed a new histogram normalization method to reduce the intensity variation between MRIs obtained from different acquisitions. In our experiment, we scanned each subject twice on two different scanners using different imaging parameters. With noise estimation, the image with lower noise level was determined and treated as the high-quality reference image. Then the histogram of the low-quality image was normalized to the histogram of the high-quality image. The normalization algorithm includes two main steps: (1) intensity scaling (IS), where, for the high-quality reference image, the intensities of the image are first rescaled to a range between the low intensity region (LIR) value and the high intensity region (HIR) value; and (2) histogram normalization (HN),where the histogram of low-quality image as input image is stretched to match the histogram of the reference image, so that the intensity range in the normalized image will also lie between LIR and HIR. We performed three sets of experiments to evaluate the proposed method, i.e., image registration, segmentation, and tissue volume measurement, and compared this with the existing intensity normalization method. It is then possible to validate that our histogram normalization framework can achieve better results in all the experiments. It is also demonstrated that the brain template with normalization preprocessing is of higher quality than the template with no normalization processing. We have proposed a histogram-based MRI intensity normalization method. The method can normalize scans which were acquired on different MRI units. We have validated that the method can greatly improve the image analysis performance. Furthermore, it is demonstrated that with the help of our normalization method, we can create a higher quality Chinese brain template.
Jiang, Shudong; Pogue, Brian W; Laughney, Ashley M; Kogel, Christine A; Paulsen, Keith D
2009-04-01
Applying localized external displacement to the breast surface can change the interstitial fluid pressure such that regional transient microvascular changes occur in oxygenation and vascular volume. Imaging these dynamic responses over time, while different pressures are applied, could provide selective temporal contrast for cancer relative to the surrounding normal breast. In order to investigate this possibility in normal breast tissue, a near-infrared spectral tomography system was developed that can simultaneously acquire data at three wavelengths with a 15 s time resolution per scan. The system was tested first with heterogeneous blood phantoms. Changes in regional blood concentrations were found to be linearly related to recovered mean hemoglobin concentration (Hb(T)) values (R(2)=0.9). In a series of volunteer breast imaging exams, data from 17 asymptomatic subjects were acquired under increasing and decreasing breast compression. Calculations show that a 10 mm displacement applied to the breast results in surface pressures in the range of 0-55 kPa depending on breast density. The recovered human data indicate that Hb(T) was reduced under compression and the normalized change was significantly correlated to the applied pressure with a p value of 0.005. The maximum Hb(T) decreases in breast tissue were associated with body mass index (BMI), which is a surrogate indicator of breast density. No statistically valid correlations were found between the applied pressure and the changes in tissue oxygen saturation (S(t)O(2)) or water percentage (H(2)O) across the range of BMI values studied.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jiang, Shudong; Pogue, Brian W.; Laughney, Ashley M.
2009-04-01
Applying localized external displacement to the breast surface can change the interstitial fluid pressure such that regional transient microvascular changes occur in oxygenation and vascular volume. Imaging these dynamic responses over time, while different pressures are applied, could provide selective temporal contrast for cancer relative to the surrounding normal breast. In order to investigate this possibility in normal breast tissue, a near-infrared spectral tomography system was developed that can simultaneously acquire data at three wavelengths with a 15 s time resolution per scan. The system was tested first with heterogeneous blood phantoms. Changes in regional blood concentrations were found tomore » be linearly related to recovered mean hemoglobin concentration (HbT) values (R{sup 2}=0.9). In a series of volunteer breast imaging exams, data from 17 asymptomatic subjects were acquired under increasing and decreasing breast compression. Calculations show that a 10 mm displacement applied to the breast results in surface pressures in the range of 0-55 kPa depending on breast density. The recovered human data indicate that HbT was reduced under compression and the normalized change was significantly correlated to the applied pressure with a p value of 0.005. The maximum HbT decreases in breast tissue were associated with body mass index (BMI), which is a surrogate indicator of breast density. No statistically valid correlations were found between the applied pressure and the changes in tissue oxygen saturation (StO2) or water percentage (H2O) across the range of BMI values studied.« less
Leveraging the Cloud for Integrated Network Experimentation
2014-03-01
kernel settings, or any of the low-level subcomponents. 3. Scalable Solutions: Businesses can build scalable solutions for their clients , ranging from...values. These values 13 can assume several distributions that include normal, Pareto , uniform, exponential and Poisson, among others [21]. Additionally, D...communication, the web client establishes a connection to the server before traffic begins to flow. Web servers do not initiate connections to clients in
... hours. Normal value ranges may vary slightly from one lab to another. Some labs use different measurements or test different samples. Talk to your provider about the meaning of your specific test results. What Abnormal Results Mean An increased level of urinary delta-ALA may ...
Kim, Sanghee; Byeon, Youngsoon
2014-04-01
Feeding methods for patients with acute stroke differ based on their ability to swallow; therefore, it is necessary to determine whether these methods deliver enough nourishment to these patients. Although nutrition could affect recovery from acute stroke, it is often overlooked. Indicators of nutritional status are important for the nutritional assessment of patients. The purpose of this study was to compare changes in nutritional indicators with various feeding methods in patients with acute stroke. Data on 261 patients with acute stroke who were admitted to a stroke unit in 2010 and met the inclusion criteria of the study were retrospectively analyzed. For comparative analysis, we investigated the participants' National Institutes of Health Stroke Scale score, feeding methods using the Modified Gugging Swallowing Screen, and indicators of nutritional status, such as body mass index, pre-albumin level, albumin level, total lymphocyte count, and total protein level. All nutritional indicators were compared at the time of admission to the stroke unit and at 7 days after admission. At the time of admission, indicators of nutritional status were within normal ranges in all feeding groups (tube, dysphagia, and general diet). At 7 days after admission, pre-albumin (P = 0.003), albumin (P = 0.001), and total protein (P = 0.000) values in the tube feeding group were below the normal range, and the pre-albumin value and total lymphocyte count were below the normal range in the dysphagia diet group (P = 0.027). The values for all nutritional indicators were within normal limits in the general diet group. Indicators of nutritional status change according to the swallowing ability of patients with acute stroke. At 7 days after admission to the stroke unit, patients with severe dysphagia had higher levels of indicators of malnutrition. Health care providers should consider whether the feeding method of each patient with stroke provides suitable nourishment. Additionally, it is important to know why these indicators vary based on swallowing abilities and what these patients require for adequate nutrition.
Normal ranges of fetal nasal bone length during the second trimester in an Iranian population.
Rahimi-Sharbaf, Fatemeh; Tahmasebpour, Ahmad-Reza; Pirjani, Reihaneh; Ghaffari, Saeed Reza; Rahimi-Foroushani, Abbas
2011-04-01
To provide a normal reference range for nasal bone length (NBL) during the second trimester of pregnancy in an Iranian population. This cross-sectional study was performed on 3201 fetuses at 15 to 28 weeks of gestational age (GA). Both singleton and twin fetuses were evaluated. The relationship between NBL and GA was determined and percentile values for each gestational week were provided. NBL measurement was obtained in 98% of singleton and 96% of twin fetuses. There was a linear relationship between GA and NBL both in singleton (R(2) = 0.62) and in twin (R(2) = 0.74) fetuses. There was no significant difference between twins regarding NBL (p = 0.18). We have provided the normal reference range for NBL during the second trimester in an Iranian population. NBL in singleton and twin fetuses is similar and there is no significant difference between twins regarding NBL. Copyright © 2011 John Wiley & Sons, Ltd.
SOLVENT EXTRACTION OF THORIUM VALUES FROM AQUEOUS SOLUTIONS
Warf, J.C.
1959-04-21
The separation of thorium values from rare earth metals contained ln aqueous solutions by means of extraction with a water immiscible alkyl phosphate diluted with a hydrocarbon such as hexane is described. While the extraction according to this invention may be carried out from any aqueous salt solution, it is preferred to use solutions containing free mineral acid. Hydrochloric acid and in particular nitric acid are sultable in a concentration ranging from 0.1 to 7 normal. The higher acid concentration results in higher extraction values.
Impaired sexual maturation associated with sleep apnea syndrome during puberty: a case study.
Mosko, S S; Lewis, E; Sassin, J F
1980-01-01
A 20-year-old hypogonadal man was discovered to have had obstructive sleep apnea syndrome--secondary to hypertrophied tonsils, adenoids, and uvula--spanning the years of puberty. All-night polysomnographic recordings and 24 hr measurements of plasma luteinizing hormone (LH) concentrations (sampling at 20 min intervals) were performed before and after combined tonsillectomy, adenoidectomy, and uvulectomy. Two weeks preoperatively, nocturnal sleep was markedly disturbed by 407 apneic episodes, and the patient was found to be hypogonadotropic. Daytime LH concentrations were in the low-normal range for an adult male, and concentrations fell dramatically during nocturnal sleep. This contrasts with both the sleep-related elevation of LH normally seen in puberty and the adult pattern, where no difference is observed in mean concentrations during waking and sleep. Two week and 6 month postoperative evaluations revealed complete alleviation of the sleep apnea syndrome and normalization of the 24 hr pattern of plasma LH, although LH values remained in the low-normal range. Plasma testosterone concentrations were in the low to low-normal range both pre- and postoperatively. No evidence of continued sexual development, beyond that achieved preoperatively, was observed 20 months after surgery, despite continued relief from apnea. These data suggest that sleep apnea during puberty may impair sexual development by preventing the sleep-related elevation in LH secretion normally observed during a critical period spanning puberty.
Normalized value coding explains dynamic adaptation in the human valuation process.
Khaw, Mel W; Glimcher, Paul W; Louie, Kenway
2017-11-28
The notion of subjective value is central to choice theories in ecology, economics, and psychology, serving as an integrated decision variable by which options are compared. Subjective value is often assumed to be an absolute quantity, determined in a static manner by the properties of an individual option. Recent neurobiological studies, however, have shown that neural value coding dynamically adapts to the statistics of the recent reward environment, introducing an intrinsic temporal context dependence into the neural representation of value. Whether valuation exhibits this kind of dynamic adaptation at the behavioral level is unknown. Here, we show that the valuation process in human subjects adapts to the history of previous values, with current valuations varying inversely with the average value of recently observed items. The dynamics of this adaptive valuation are captured by divisive normalization, linking these temporal context effects to spatial context effects in decision making as well as spatial and temporal context effects in perception. These findings suggest that adaptation is a universal feature of neural information processing and offer a unifying explanation for contextual phenomena in fields ranging from visual psychophysics to economic choice.
Classification of the height and flexibility of the medial longitudinal arch of the foot.
Nilsson, Mette Kjærgaard; Friis, Rikke; Michaelsen, Maria Skjoldahl; Jakobsen, Patrick Abildgaard; Nielsen, Rasmus Oestergaard
2012-02-17
The risk of developing injuries during standing work may vary between persons with different foot types. High arched and low arched feet, as well as rigid and flexible feet, are considered to have different injury profiles, while those with normal arches may sustain fewer injuries. However, the cut-off values for maximum values (subtalar position during weight-bearing) and range of motion (ROM) values (difference between subtalar neutral and subtalar resting position in a weight-bearing condition) for the medial longitudinal arch (MLA) are largely unknown. The purpose of this study was to identify cut-off values for maximum values and ROM of the MLA of the foot during static tests and to identify factors influencing foot posture. The participants consisted of 254 volunteers from Central and Northern Denmark (198 m/56 f; age 39.0 ± 11.7 years; BMI 27.3 ± 4.7 kg/m2). Navicular height (NH), longitudinal arch angle (LAA) and Feiss line (FL) were measured for either the left or the right foot in a subtalar neutral position and subtalar resting position. Maximum values and ROM were calculated for each test. The 95% and 68% prediction intervals were used as cut-off limits. Multiple regression analysis was used to detect influencing factors on foot posture. The 68% cut-off values for maximum MLA values and MLA ROM for NH were 3.6 to 5.5 cm and 0.6 to 1.8 cm, respectively, without taking into account the influence of other variables. Normal maximum LAA values were between 131 and 152° and normal LAA ROM was between -1 and 13°. Normal maximum FL values were between -2.6 and -1.2 cm and normal FL ROM was between -0.1 and 0.9 cm. Results from the multivariate linear regression revealed an association between foot size with FL, LAA, and navicular drop. The cut-off values presented in this study can be used to categorize people performing standing work into groups of different foot arch types. The results of this study are important for investigating a possible link between arch height and arch movement and the development of injuries.
Variability in monthly serum bicarbonate measures in hemodialysis patients: a cohort study.
Patel, Ravi; Paredes, William; Hall, Charles B; Nader, Mark A; Sapkota, Deepak; Folkert, Vaughn W; Abramowitz, Matthew K
2015-12-21
Some nephrologists have advocated an individualized approach to the prescription of bicarbonate hemodialysis. However, the utility of monthly serum bicarbonate levels for guiding and evaluating such treatment decisions has not been evaluated. We sought to define the variability of these measurements and to determine factors that are associated with month-to-month variability in pre-dialysis serum bicarbonate. We examined the monthly variability in serum bicarbonate measurements among 181 hemodialysis patients admitted to a free-standing dialysis unit in the Bronx, NY from 1/1/2008-6/30/2012. All patients were treated with a uniform bicarbonate dialysis prescription (bicarbonate 35 mEq/L, acetate 8 mEq/L). Pre-dialysis serum bicarbonate values were obtained from monthly laboratory reports. Month-to-month variability was defined using a rolling measurement for each time point. Only 34 % of high serum bicarbonate values (>26 mEq/L) remained high in the subsequent month, whereas 60 % converted to normal (22-26 mEq/L). Of all low values (<22 mEq/L), 41 % were normal the following month, while 58 % remained low. Using the mean 3-month bicarbonate, only 29 % of high values remained high in the next 3-month period. In multivariable-adjusted longitudinal models, both low and high serum bicarbonate values were associated with greater variability than were normal values (β = 0.12 (95 % CI 0.09-0.15) and 0.24 (0.18 to 0.29) respectively). Variability decreased with time, and was significantly associated with age, phosphate binder use, serum creatinine, potassium, and normalized protein catabolic rate. Monthly pre-dialysis serum bicarbonate levels are highly variable. Even if a clinician takes no action, approximately 50 % of bicarbonate values outside a normal range of 22-26 mEq/L will return to normal in the subsequent month. The decision to change the bicarbonate dialysis prescription should not be based on a single bicarbonate value, and even a 3-month mean may be insufficient.
Hyperglycemia may determine fibrinopeptide A plasma level increase in humans.
Ceriello, A; Giugliano, D; Quatraro, A; Dello Russo, P; Marchi, E; Torella, R
1989-12-01
The effects of hyperglycemia on plasma fibrinopeptide A (FPA) levels in normal subjects are reported. An increase of FPA concentration parallel to sustained hyperglycemia was observed; when the glycemia returned to basal values, FPA showed values in normal range. Heparin infusion was able to significantly decrease the hyperglycemia-induced augment of FPA levels. Isovolumic-isotonic NaCl solution infusion produced a slight (NS) increase in FPA levels; however, mild hyperglycemia, achieved by glucagon, was also able to produce a significant increase in FPA concentration. These data demonstrate the direct role of hyperglycemia in conditioning FPA level, and suggest that hyperglycemia, by itself, is a sufficient stimulus to produce thrombin activation in humans.
Validation of the plain chest radiograph for epidemiologic studies of airflow obstruction
DOE Office of Scientific and Technical Information (OSTI.GOV)
Musk, A.W.
The chest radiographs of 125 industrial workers from rural New South Wales were examined for overinflated lungs, with and without attenuated midzonal vessels. Although the mean values of a comprehensive range of pulmonary function tests in the whole group were within normal limits, the nine subjects whose radiographs showed overinflated lungs and attenuated vessels had significantly impaired pulmonary function in comparison with 85 subjects with normal radiographs. The mean values for these nine subjects, expressed as a percentage of the mean value for subjects with normal radiographs, were: forced expiratory volume in 1 second, 75%; total lung capacity, 107%; residualmore » volume, 143%; transpulmonary pressure at maximum inspiration, 60%; static deflation compliance, 158%; lung volume at transpulmonary pressure 10 cm H/sub 2/O, 132%; transfer factor, 79%; and transfer factor/alveolar volume, 77%. Similar results were obtained by a second observer. Those subjects with overinflation but no vascular attenuation had significantly larger mean values for vital capacity and alveolar volume but no significant difference in total lung capacity or other tests of the mechanical properties of the lungs. Agreement on the presence of a positive sign between the two observers expressed as a percentage of those considered positive by either was 81% for overinflation and 62% for attenuated midzonal vessels. The results indicate that in groups of subjects with normal-average values of pulmonary function, the plain chest radiograph may provide information concerning pulmonary structure that is reflected in tests of function.« less
Digital ranges of motion: normal values in young adults.
Mallon, W J; Brown, H R; Nunley, J A
1991-09-01
Analysis of the range of motion of fingers was done in young (eighteen to thirty-five year old) adult volunteers with no history of previous injury to their hands. The data show that there are slight differences between the individual digits. Notably, metacarpophalangeal flexion and total active motion increase linearly in proceeding from the index to the small finger. There were also minor differences in comparing sexes. Women have greater extension at the metacarpophalangeal joint in both active and passive motion and have a greater total active motion at all digits as a result. A significant tenodesis effect was found at the distal interphalangeal joint in normal subjects. No differences were found that could be attributable to handedness.
Size distribution of radon daughter particles in uranium mine atmospheres.
George, A C; Hinchliffe, L; Sladowski, R
1975-06-01
The size distribution of radon daughters was measured in several uranium mines using four compact diffusion batteries and a round jet cascade impactor. Simultaneously, measurements were made of uncombined fractions of radon daughters, radon concentration, working level and particle concentration. The size distributions found for radon daughters were log normal. The activity median diameters ranged from 0.09 mum to 0.3 mum with a mean value of 0.17 mum. Geometric standard deviations were in the range from 1.3 to 4 with a mean value of 2.7. Uncombined fractions expressed in accordance with the ICRP definition ranged from 0.004 to 0.16 with a mean value of 0.04. The radon daughter sizes in these mines are greater than the sizes assumed by various authors in calculating respiratory tract dose. The disparity may reflect the widening use of diesel-powered equipment in large uranium mines.
Wang, Hui; Wang, Yiping; Zhou, Zhenwei; Wang, Shuo; Yin, Hongyin; Xie, Keqin
2015-06-01
To determine the normal reference value of pyrrole adducts in urine in young people in a university in Shandong, China, and to provide a reliable basis for the clinical diagnosis of n-hexane poisoning. A total of 240 college students were randomly selected. After excluding 32 ineligible students, 208 subjects were included in this study, consisting of 104 males and 104 females, with a mean age of 21?3 years (range: 18 to 24 years). Morning urine was collected from each subject. The content of pyrrole adducts was determined by chromatometry. The content of pyrrole adducts in both male and female obeyed a positively skewed distribution. The median level of pyrrole adducts in male subjects was 0.88 nmol/ml, and the reference value was 0.14-3.92 nmol/ml. The median level of pyrrole adducts in female subjects was 0.93 nmol/ ml, and the reference value was 0.09-3.27 nmol/ml. Student's t test identified no statistical difference in pyrrole adduct level between male and female subjects (t=0.15, P>0.05). The median level of pyrrole adducts in normal young people is 0.91 nmol/ml, and the reference value is 0.11-3.95 nmol/ml.
NASA Technical Reports Server (NTRS)
Reschke, Millard F.; Somers, Jeffrey T.; Feiveson, Alan H.; Leigh, R. John; Wood, Scott J.; Paloski, William H.; Kornilova, Ludmila
2006-01-01
We studied the ability to hold the eyes in eccentric horizontal or vertical gaze angles in 68 normal humans, age range 19-56. Subjects attempted to sustain visual fixation of a briefly flashed target located 30 in the horizontal plane and 15 in the vertical plane in a dark environment. Conventionally, the ability to hold eccentric gaze is estimated by fitting centripetal eye drifts by exponential curves and calculating the time constant (t(sub c)) of these slow phases of gazeevoked nystagmus. Although the distribution of time-constant measurements (t(sub c)) in our normal subjects was extremely skewed due to occasional test runs that exhibited near-perfect stability (large t(sub c) values), we found that log10(tc) was approximately normally distributed within classes of target direction. Therefore, statistical estimation and inference on the effect of target direction was performed on values of z identical with log10t(sub c). Subjects showed considerable variation in their eyedrift performance over repeated trials; nonetheless, statistically significant differences emerged: values of tc were significantly higher for gaze elicited to targets in the horizontal plane than for the vertical plane (P less than 10(exp -5), suggesting eccentric gazeholding is more stable in the horizontal than in the vertical plane. Furthermore, centrifugal eye drifts were observed in 13.3, 16.0 and 55.6% of cases for horizontal, upgaze and downgaze tests, respectively. Fifth percentile values of the time constant were estimated to be 10.2 sec, 3.3 sec and 3.8 sec for horizontal, upward and downward gaze, respectively. The difference between horizontal and vertical gazeholding may be ascribed to separate components of the velocity position neural integrator for eye movements, and to differences in orbital mechanics. Our statistical method for representing the range of normal eccentric gaze stability can be readily applied in a clinical setting to patients who were exposed to environments that may have modified their central integrators and thus require monitoring. Patients with gaze-evoked nystagmus can be flagged by comparing to the above established normative criteria.
Chaumoitre, K; Colavolpe, N; Shojai, R; Sarran, A; D' Ercole, C; Panuel, M
2007-01-01
To assess the use of diffusion-weighted magnetic resonance imaging (DW-MRI) in the evaluation of the fetal kidney and to estimate age-dependent changes in the apparent diffusion coefficient (ADC) of normal and pathological fetal kidneys. DW-MRI was performed on a 1.5-T machine at 23-38 gestational weeks in 51 pregnant women in whom the fetal kidneys were normal and in 10 whose fetuses had renal pathology (three with suspected nephropathy, three with renal tract dilatation, one with unilateral renal venous thrombosis, and three with twin-twin transfusion syndrome (TTTS)). The ADC was measured in an approximately 1-cm2 region of interest within the renal parenchyma. ADC values in normal renal parenchyma ranged from 1.1 to 1.8 10(-3) mm2 s-1. There was no significant age-dependent change in the ADC of normal kidneys. In cases of nephropathy, the ADC value was not always pathological but an ADC map could show abnormal findings. In cases of dilatation, the ADC value was difficult to determine when the dilatation was huge. In cases of TTTS, the ADC of the donor twin was higher than that of the recipient twin and the difference seemed to be related to the severity of the syndrome. Evaluation of the ADC for fetal kidneys is feasible. Fetal measurement of the ADC value and ADC maps may be useful tools with which to explore the fetal kidney when used in conjunction with current methods. DW-MR images, ADC value and ADC map seem to be useful in cases of suspected nephropathy (hyperechoic kidneys), dilated kidney and vascular pathology (renal venous thrombosis, TTTS). Copyright (c) 2006 ISUOG.
A meta-analysis of clinical electro-oculography values.
Constable, Paul A; Ngo, David; Quinn, Stephen; Thompson, Dorothy A
2017-12-01
The aim of the meta-analysis was to derive a range of mean normal clinical electrooculogram (EOG) values from a systematic review of published EOG studies that followed the guidelines of the ISCEV standard for clinical electro-oculography. A systematic literature review was performed using four relevant databases limited to peer-reviewed articles in English between 1967 and February 2017. Studies reporting clinical EOG or FO normal values were included when the report used a standard 30° horizontal saccade, a retinal luminance of between 100 and 250 cd m -2 , and had > 10 subjects in their normative values. The search identified 1145 articles after duplicates were removed with subsequent screening of the abstracts excluding a further 1098, resulting in 47 full-text articles that were then assessed by the author (PC) with a final nine articles meeting the inclusion criteria. An overall effect estimate using inverse variance-weighted meta-analysis was performed to estimate the mean values for the light peak/dark trough ratio (LP:DT ratio) (dilated and undilated), the time to the LP, the amplitude of the LP, dark trough (DT) and the fast oscillation (FO) peak-to-trough ratio from the included studies. The mean dilated LP:DT ratio was 2.35 (95% CI 2.28-2.42); undilated LP:DT ratio was 2.37 (95% CI 2.28-2.45); LP amplitude was 835 (95% CI 631-1039) µV and the mean time to the LP being 8.2 (95% CI 7.7-8.7) min. The mean DT amplitude was 358 (95% CI 292-424) µV, and the mean FO peak-to-trough ratio was 1.13 (95% CI 1.11-1.16). The results of the LP/DT ratio are drawn from studies with a mean ± standard deviation (SD) age of 34.08 ± 12.93 years for dilated and 33.65 ± 12.28 years for undilated LP/DT ratios. The meta-analysis of EOG studies has generated a reference range of normal mean values for clinicians to refer to when using the ISCEV clinical EOG. It provides a potential method to generate similar data sets from published normal values in related visual electrophysiology tests.
Meinel, Felix G.; Schwab, Felix; Schleede, Simone; Bech, Martin; Herzen, Julia; Achterhold, Klaus; Auweter, Sigrid; Bamberg, Fabian; Yildirim, Ali Ö.; Bohla, Alexander; Eickelberg, Oliver; Loewen, Rod; Gifford, Martin; Ruth, Ronald; Reiser, Maximilian F.; Pfeiffer, Franz; Nikolaou, Konstantin
2013-01-01
Purpose To assess whether grating-based X-ray dark-field imaging can increase the sensitivity of X-ray projection images in the diagnosis of pulmonary emphysema and allow for a more accurate assessment of emphysema distribution. Materials and Methods Lungs from three mice with pulmonary emphysema and three healthy mice were imaged ex vivo using a laser-driven compact synchrotron X-ray source. Median signal intensities of transmission (T), dark-field (V) and a combined parameter (normalized scatter) were compared between emphysema and control group. To determine the diagnostic value of each parameter in differentiating between healthy and emphysematous lung tissue, a receiver-operating-characteristic (ROC) curve analysis was performed both on a per-pixel and a per-individual basis. Parametric maps of emphysema distribution were generated using transmission, dark-field and normalized scatter signal and correlated with histopathology. Results Transmission values relative to water were higher for emphysematous lungs than for control lungs (1.11 vs. 1.06, p<0.001). There was no difference in median dark-field signal intensities between both groups (0.66 vs. 0.66). Median normalized scatter was significantly lower in the emphysematous lungs compared to controls (4.9 vs. 10.8, p<0.001), and was the best parameter for differentiation of healthy vs. emphysematous lung tissue. In a per-pixel analysis, the area under the ROC curve (AUC) for the normalized scatter value was significantly higher than for transmission (0.86 vs. 0.78, p<0.001) and dark-field value (0.86 vs. 0.52, p<0.001) alone. Normalized scatter showed very high sensitivity for a wide range of specificity values (94% sensitivity at 75% specificity). Using the normalized scatter signal to display the regional distribution of emphysema provides color-coded parametric maps, which show the best correlation with histopathology. Conclusion In a murine model, the complementary information provided by X-ray transmission and dark-field images adds incremental diagnostic value in detecting pulmonary emphysema and visualizing its regional distribution as compared to conventional X-ray projections. PMID:23555692
Meinel, Felix G; Schwab, Felix; Schleede, Simone; Bech, Martin; Herzen, Julia; Achterhold, Klaus; Auweter, Sigrid; Bamberg, Fabian; Yildirim, Ali Ö; Bohla, Alexander; Eickelberg, Oliver; Loewen, Rod; Gifford, Martin; Ruth, Ronald; Reiser, Maximilian F; Pfeiffer, Franz; Nikolaou, Konstantin
2013-01-01
To assess whether grating-based X-ray dark-field imaging can increase the sensitivity of X-ray projection images in the diagnosis of pulmonary emphysema and allow for a more accurate assessment of emphysema distribution. Lungs from three mice with pulmonary emphysema and three healthy mice were imaged ex vivo using a laser-driven compact synchrotron X-ray source. Median signal intensities of transmission (T), dark-field (V) and a combined parameter (normalized scatter) were compared between emphysema and control group. To determine the diagnostic value of each parameter in differentiating between healthy and emphysematous lung tissue, a receiver-operating-characteristic (ROC) curve analysis was performed both on a per-pixel and a per-individual basis. Parametric maps of emphysema distribution were generated using transmission, dark-field and normalized scatter signal and correlated with histopathology. Transmission values relative to water were higher for emphysematous lungs than for control lungs (1.11 vs. 1.06, p<0.001). There was no difference in median dark-field signal intensities between both groups (0.66 vs. 0.66). Median normalized scatter was significantly lower in the emphysematous lungs compared to controls (4.9 vs. 10.8, p<0.001), and was the best parameter for differentiation of healthy vs. emphysematous lung tissue. In a per-pixel analysis, the area under the ROC curve (AUC) for the normalized scatter value was significantly higher than for transmission (0.86 vs. 0.78, p<0.001) and dark-field value (0.86 vs. 0.52, p<0.001) alone. Normalized scatter showed very high sensitivity for a wide range of specificity values (94% sensitivity at 75% specificity). Using the normalized scatter signal to display the regional distribution of emphysema provides color-coded parametric maps, which show the best correlation with histopathology. In a murine model, the complementary information provided by X-ray transmission and dark-field images adds incremental diagnostic value in detecting pulmonary emphysema and visualizing its regional distribution as compared to conventional X-ray projections.
Regional reference values of thyroid gland volume in Turkish Adults.
Şahin, Ertan; Elboğa, Umut; Kalender, Ebuzer
2015-01-01
It is important to know the size of the thyroid gland, and its normal value may vary among different geographic regions. In this study, we aimed to establish reference ranges for thyroid volume in euthyroid adults and to compare these results with the literature data. Between June 2011 and June 2012,461 patients with normal laboratory results (serum TSH, anti-TG, anti-TPO antibodies and urine iodine level) that underwent thyroid gland ultrasound examination were retrospectively analyzed.Two hundred and 92 patients were females and 169 were males; the age range was 18-61 years with mean age 30.84±9.97 years. Length, breadth and thickness were measured, and the volume of each lobe was estimated using the ellipsoid formula. The overall mean thyroid volume in all patients who were examined was 12.98±2.53 mL. The mean thyroid volume in females and males was 12.09±2.05 mL and 14.53±2.55, respectively (p<0.05). The right thyroid lobe volume was greater than the left in all patients of both sexes. In addition, the study establishes a significant correlation between the thyroid volume and height, weight and body surface area of the subjects of both sexes (p<0.05). In the light of our findings we can provide reference values in order to evaluate patients who have thyroid hyperplasia or who are considered as normal. We consider that further studies are necessary to establish national references thyroid volume for each country.
Erythropoiesis and erythropoietin in hypo- and hyperthyroidism.
Das, K C; Mukherjee, M; Sarkar, T K; Dash, R J; Rastogi, G K
1975-02-01
Qualitative and quantitative studies of erythropoiesis in 23 patients with hypothyroidism and 21 patients with hyperthryoidism included routine hematologic evaluation, bone marrow morphology, status of serum iron, B12 and folate red blood cell mass and plasma volume by radioisotope methods, erythrokinetics and radiobioassay of plasma erythropoietin. A majority of patients with the hypothyroid state had significant reduction in red blood cell mas per kg of body weight. The presence of anemia in many of these patients was not evident from hemoglobin and hematocrit values due to concomitant reduction of plasma volume. The erythrokinetic data in hypothyroid patients provided evidence of significant decline of the erythropoietic activity of the bone marrow. Erythroid cells in the marrow were depleted and also showed reduced proliferative activity as indicated by lower 3H-thymidine labeling index. Plasma erythropoietin levels were reduced, often being immeasurable by the polycythemic mouse bioassay technique. These changes in erythropoiesis in the hypothyroid state appear to be a part of physiological adjustment to the reduced oxygen requirement of the tissues due to diminished basal metabolic rate. Similar investigations revealed mild erythrocytosis in a significant proportion of patients with hyperthyroidism. Failure of erythrocytosis to occur in other patients of this group was associated with impaired erythropoiesis due to a deficiency of hemopoietic nutrients such as iron, vitamin B12 and folate. The mean plasma erythropoietin level of these patients was significantly elevated; in 4 patients the levels were in the upper normal range whereas in the rest, the values were above the normal range. The bone marrow showed erythyroid hyperplasia in all patients with hyperthyroidism. The mean 3H-thymidine labeling index of the erythroblasts was also significantly higher than normal in hyperthyroidism; in 8 patients the index was within the normal range whereas in the remaining 13 it was above the normal range. Erythrokinetic studies also provided evidences of increased erythropoietic activity in the bone marrow. It is postulated that thyroid hormones stimulate erythropoiesis, sometimes leading to erythrocytosis provided there is no deficiency of hemopoietic nutrients. Stimulation of erythropoiesis by thryoid hormones appears to be mediated through erythropoietin.
Speaker normalization for chinese vowel recognition in cochlear implants.
Luo, Xin; Fu, Qian-Jie
2005-07-01
Because of the limited spectra-temporal resolution associated with cochlear implants, implant patients often have greater difficulty with multitalker speech recognition. The present study investigated whether multitalker speech recognition can be improved by applying speaker normalization techniques to cochlear implant speech processing. Multitalker Chinese vowel recognition was tested with normal-hearing Chinese-speaking subjects listening to a 4-channel cochlear implant simulation, with and without speaker normalization. For each subject, speaker normalization was referenced to the speaker that produced the best recognition performance under conditions without speaker normalization. To match the remaining speakers to this "optimal" output pattern, the overall frequency range of the analysis filter bank was adjusted for each speaker according to the ratio of the mean third formant frequency values between the specific speaker and the reference speaker. Results showed that speaker normalization provided a small but significant improvement in subjects' overall recognition performance. After speaker normalization, subjects' patterns of recognition performance across speakers changed, demonstrating the potential for speaker-dependent effects with the proposed normalization technique.
An echocardiographic study of healthy Border Collies with normal reference ranges for the breed.
Jacobson, Jake H; Boon, June A; Bright, Janice M
2013-06-01
The objectives of this study were to obtain standard echocardiographic measurements from healthy Border Collies and to compare these measurements to those previously reported for a general population of dogs. Standard echocardiographic data were obtained from twenty apparently healthy Border Collie dogs. These data (n = 20) were compared to data obtained from a general population of healthy dogs (n = 69). Border Collies were deemed healthy based on normal history, physical examination, complete blood count, serum biochemical profile, electrocardiogram, and blood pressure, with no evidence of congenital or acquired heart disease on echocardiographic examination. Standard two dimensional, M-mode, and Doppler echocardiographic measurements were obtained and normal ranges determined. The data were compared to data previously obtained at our hospital from a general population of normal dogs. Two dimensional, M-mode, and Doppler reference ranges for healthy Border Collies are presented in tabular form. Comparison of the weight adjusted M-mode echocardiographic means from Border Collies to those from the general population of dogs showed Border Collies to have larger left ventricular systolic and diastolic dimensions, smaller interventricular septal thickness, and lower fractional shortening. There are differences in some echocardiographic parameters between healthy Border Collies and the general dog population, and the echocardiographic reference ranges provided in this study should be used as breed specific reference values for Border Collies. Copyright © 2013 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Smith, C; Cunliffe, A; Al-Hallaq, H
Purpose: To determine the stability of eight first-order texture features following the deformable registration of serial computed tomography (CT) scans. Methods: CT scans at two different time points from 10 patients deemed to have no lung abnormalities by a radiologist were collected. Following lung segmentation using an in-house program, texture maps were calculated from 32×32-pixel regions of interest centered at every pixel in the lungs. The texture feature value of the ROI was assigned to the center pixel of the ROI in the corresponding location of the texture map. Pixels in the square ROI not contained within the segmented lungmore » were not included in the calculation. To quantify the agreement between ROI texture features in corresponding pixels of the baseline and follow-up texture maps, the Fraunhofer MEVIS EMPIRE10 deformable registration algorithm was used to register the baseline and follow-up scans. Bland-Altman analysis was used to compare registered scan pairs by computing normalized bias (nBias), defined as the feature value change normalized to the mean feature value, and normalized range of agreement (nRoA), defined as the range spanned by the 95% limits of agreement normalized to the mean feature value. Results: Each patient’s scans contained between 6.8–15.4 million ROIs. All of the first-order features investigated were found to have an nBias value less than 0.04% and an nRoA less than 19%, indicating that the variability introduced by deformable registration was low. Conclusion: The eight first-order features investigated were found to be registration stable. Changes in CT texture maps could allow for temporal-spatial evaluation of the evolution of lung abnormalities relating to a variety of diseases on a patient-by-patient basis. SGA and HA receives royalties and licensing fees through the University of Chicago for computer-aided diagnosis technology. Research reported in this publication was supported by the National Institute Of General Medical Sciences of the National Institutes of Health under Award Number R25GM109439.« less
Analysis of using the tongue deviation angle as a warning sign of a stroke
2012-01-01
Background The symptom of tongue deviation is observed in a stroke or transient ischemic attack. Nevertheless, there is much room for the interpretation of the tongue deviation test. The crucial factor is the lack of an effective quantification method of tongue deviation. If we can quantify the features of the tongue deviation and scientifically verify the relationship between the deviation angle and a stroke, the information provided by the tongue will be helpful in recognizing a warning of a stroke. Methods In this study, a quantification method of the tongue deviation angle was proposed for the first time to characterize stroke patients. We captured the tongue images of stroke patients (15 males and 10 females, ranging between 55 and 82 years of age); transient ischemic attack (TIA) patients (16 males and 9 females, ranging between 53 and 79 years of age); and normal subjects (14 males and 11 females, ranging between 52 and 80 years of age) to analyze whether the method is effective. In addition, we used the receiver operating characteristic curve (ROC) for the sensitivity analysis, and determined the threshold value of the tongue deviation angle for the warning sign of a stroke. Results The means and standard deviations of the tongue deviation angles of the stroke, TIA, and normal groups were: 6.9 ± 3.1, 4.9 ± 2.1 and 1.4 ± 0.8 degrees, respectively. Analyzed by the unpaired Student’s t-test, the p-value between the stroke group and the TIA group was 0.015 (>0.01), indicating no significant difference in the tongue deviation angle. The p-values between the stroke group and the normal group, as well as between the TIA group and the normal group were both less than 0.01. These results show the significant differences in the tongue deviation angle between the patient groups (stroke and TIA patients) and the normal group. These results also imply that the tongue deviation angle can effectively identify the patient group (stroke and TIA patients) and the normal group. With respect to the visual examination, 40% and 32% of stroke patients, 24% and 16% of TIA patients, and 4% and 0% of normal subjects were found to have tongue deviations when physicians “A” and “B” examined them. The variation showed the essentiality of the quantification method in a clinical setting. In the receiver operating characteristic curve (ROC), the Area Under Curve (AUC, = 0.96) indicates good discrimination. The tongue deviation angle more than the optimum threshold value (= 3.2°) predicts a risk of stroke. Conclusions In summary, we developed an effective quantification method to characterize the tongue deviation angle, and we confirmed the feasibility of recognizing the tongue deviation angle as an early warning sign of an impending stroke. PMID:22908956
Analysis of using the tongue deviation angle as a warning sign of a stroke.
Wei, Ching-Chuan; Huang, Shu-Wen; Hsu, Sheng-Lin; Chen, Hsing-Chung; Chen, Jong-Shin; Liang, Hsinying
2012-08-21
The symptom of tongue deviation is observed in a stroke or transient ischemic attack. Nevertheless, there is much room for the interpretation of the tongue deviation test. The crucial factor is the lack of an effective quantification method of tongue deviation. If we can quantify the features of the tongue deviation and scientifically verify the relationship between the deviation angle and a stroke, the information provided by the tongue will be helpful in recognizing a warning of a stroke. In this study, a quantification method of the tongue deviation angle was proposed for the first time to characterize stroke patients. We captured the tongue images of stroke patients (15 males and 10 females, ranging between 55 and 82 years of age); transient ischemic attack (TIA) patients (16 males and 9 females, ranging between 53 and 79 years of age); and normal subjects (14 males and 11 females, ranging between 52 and 80 years of age) to analyze whether the method is effective. In addition, we used the receiver operating characteristic curve (ROC) for the sensitivity analysis, and determined the threshold value of the tongue deviation angle for the warning sign of a stroke. The means and standard deviations of the tongue deviation angles of the stroke, TIA, and normal groups were: 6.9 ± 3.1, 4.9 ± 2.1 and 1.4 ± 0.8 degrees, respectively. Analyzed by the unpaired Student's t-test, the p-value between the stroke group and the TIA group was 0.015 (>0.01), indicating no significant difference in the tongue deviation angle. The p-values between the stroke group and the normal group, as well as between the TIA group and the normal group were both less than 0.01. These results show the significant differences in the tongue deviation angle between the patient groups (stroke and TIA patients) and the normal group. These results also imply that the tongue deviation angle can effectively identify the patient group (stroke and TIA patients) and the normal group. With respect to the visual examination, 40% and 32% of stroke patients, 24% and 16% of TIA patients, and 4% and 0% of normal subjects were found to have tongue deviations when physicians "A" and "B" examined them. The variation showed the essentiality of the quantification method in a clinical setting. In the receiver operating characteristic curve (ROC), the Area Under Curve (AUC, = 0.96) indicates good discrimination. The tongue deviation angle more than the optimum threshold value (= 3.2°) predicts a risk of stroke. In summary, we developed an effective quantification method to characterize the tongue deviation angle, and we confirmed the feasibility of recognizing the tongue deviation angle as an early warning sign of an impending stroke.
Srinivas, M; Jain, M; Bawane, P; Jayanthi, V
2018-06-01
High-resolution esophageal manometry (HREM) interpretation by the Chicago Classification (CC) derives its normal values from western volunteers using solid-state catheters. There is no normative data for the 16-channel water-perfused HREM system commonly used in India. To determine normal values for a 16-channel water-perfused HREM catheter in supine posture using healthy volunteers and substitute these normal values (if different from CC values) in the CC v3.0 algorithm. After ethics approval and informed consent, 53 volunteers (31 men) with no gastrointestinal (GI) symptoms or medications affecting GI motility underwent HREM by standard protocol. Age, gender, body mass index (BMI), and manometry parameters analyzed using Trace 1.3.3 software were collected. The median, range, and 5, 10, 75, and 95 percentiles (where applicable) were obtained for all HREM metrics. Normal value percentiles were defined as 95th (integrated relaxation pressure [IRP]), 10th-100th (distal contractile integral [DCI]), and minimum (distal latency [DL]). The mean age was 30 years and the BMI was 24.2 kg m -2 . Compared to CC, our normal metrics were lower for IRP (13 mm Hg) and DCI (350-4500 mm Hg s cm). DCI >4500 and <70 (<5th percentile) were defined as hypercontractile and failed contraction, respectively. Abnormal DL (<4.5 s) and peristaltic break size (>5 cm) were similar to CC metrics. Applying these metrics, CC diagnoses changed in 15% (8/53) with downgrading of ineffective motility to fragmented peristalsis or normal, due to lower DCI cutoff used. This is the first report of normative data for the 16-channel water-perfused system in supine posture. It revealed lower IRP and DCI, necessitating modification of CC cutoffs for this system. © 2018 John Wiley & Sons Ltd.
Wang, Yimin; Fawzi, Amani; Tan, Ou; Gil-Flamer, John; Huang, David
2010-01-01
We present human retinal blood flow investigation for diabetic patients using Doppler Fourier domain optical coherence tomography (FD-OCT). The scanning pattern consisted of two concentric circles around the optic nerve head. The blood flow in one patient with diabetes and no retinpathy and another patient with treated proliferative diabetic retinopathy were measured. The patient without retinopathy showed a total blood flow value at the lower level of the normal range. The flow distribution between superior and inferior retina was balanced. The patient with diabetic retinopathy had a flow value lower than the normal people. Our study shows that Doppler FD-OCT can be used to evaluate the total retinal blood flow in patients with retinal diseases. PMID:19259246
Verdurmen, Kim M J; Lempersz, Carlijn; Vullings, Rik; Schroer, Christian; Delhaas, Tammo; van Laar, Judith O E H; Oei, S Guid
2016-08-17
The fetal anomaly ultrasound only detects 65 to 81 % of the patients with congenital heart disease, making it the most common structural fetal anomaly of which a significant part is missed during prenatal life. Therefore, we need a reliable non-invasive diagnostic method which improves the predictive value for congenital heart diseases early in pregnancy. Fetal electrocardiography could be this desired diagnostic method. There are multiple technical challenges to overcome in the conduction of the fetal electrocardiogram. In addition, interpretation is difficult due to the organisation of the fetal circulation in utero. We want to establish the normal ranges and values of the fetal electrocardiogram parameters in healthy fetuses of 18 to 24 weeks of gestation. Women with an uneventful singleton pregnancy between 18 and 24 weeks of gestation are asked to participate in this prospective cohort study. A certified and experienced sonographist performs the fetal anomaly scan. Subsequently, a fetal electrocardiogram recording is performed using dedicated signal processing methods. Measurements are performed at two institutes. We will include 300 participants to determine the normal values and 95 % confidence intervals of the fetal electrocardiogram parameters in a healthy fetus. We will evaluate the fetal heart rate, segment intervals, normalised amplitude and the fetal heart axis. Three months postpartum, we will evaluate if a newborn is healthy through a questionnaire. Fetal electrocardiography could be a promising tool in the screening program for congenital heart diseases. The electrocardiogram is a depiction of the intimate relationship between the cardiac nerve conduction pathways and the structural morphology of the fetal heart, and therefore particularly suitable for the detection of secondary effects due to a congenital heart disease (hypotrophy, hypertrophy and conduction interruption).
Quantitative Ultrasound Assessment of Duchenne Muscular Dystrophy Using Edge Detection Analysis.
Koppaka, Sisir; Shklyar, Irina; Rutkove, Seward B; Darras, Basil T; Anthony, Brian W; Zaidman, Craig M; Wu, Jim S
2016-09-01
The purpose of this study was to investigate the ability of quantitative ultrasound (US) using edge detection analysis to assess patients with Duchenne muscular dystrophy (DMD). After Institutional Review Board approval, US examinations with fixed technical parameters were performed unilaterally in 6 muscles (biceps, deltoid, wrist flexors, quadriceps, medial gastrocnemius, and tibialis anterior) in 19 boys with DMD and 21 age-matched control participants. The muscles of interest were outlined by a tracing tool, and the upper third of the muscle was used for analysis. Edge detection values for each muscle were quantified by the Canny edge detection algorithm and then normalized to the number of edge pixels in the muscle region. The edge detection values were extracted at multiple sensitivity thresholds (0.01-0.99) to determine the optimal threshold for distinguishing DMD from normal. Area under the receiver operating curve values were generated for each muscle and averaged across the 6 muscles. The average age in the DMD group was 8.8 years (range, 3.0-14.3 years), and the average age in the control group was 8.7 years (range, 3.4-13.5 years). For edge detection, a Canny threshold of 0.05 provided the best discrimination between DMD and normal (area under the curve, 0.96; 95% confidence interval, 0.84-1.00). According to a Mann-Whitney test, edge detection values were significantly different between DMD and controls (P < .0001). Quantitative US imaging using edge detection can distinguish patients with DMD from healthy controls at low Canny thresholds, at which discrimination of small structures is best. Edge detection by itself or in combination with other tests can potentially serve as a useful biomarker of disease progression and effectiveness of therapy in muscle disorders.
Gastric emptying of solids in children: reference values for the (13) C-octanoic acid breath test.
Hauser, B; Roelants, M; De Schepper, J; Veereman, G; Caveliers, V; Devreker, T; De Greef, E; Vandenplas, Y
2016-10-01
(99m) Technetium scintigraphy ((99m) TS) is the 'gold standard' for measuring gastric emptying (GE), but it is associated with a radiation exposure. For this reason, the (13) C-octanoic acid breath test ((13) C-OBT) was developed for measuring GE of solids. The objective of this study was to determine normal values for gastric half-emptying time (t1/2 GE) of solids in healthy children. Gastric emptying of a standardized solid test meal consisting of a pancake evaluated with (99m) TS and (13) C-OBT was compared in 22 children aged between 1 and 15 years with upper gastrointestinal symptoms. Subsequently, the (13) C-OBT was used to determine normal values for GE of the same solid test meal in 120 healthy children aged between 1 and 17 years. The results showed a significant correlation (r = 0.748, p = 0.0001) between t1/2 GE measured with both techniques in the group of children with upper gastrointestinal symptoms. In the group of healthy children, mean t1/2 GE was 157.7 ± 54.0 min (range 71-415 min), but t1/2 GE decreased with age between 1 and 10 years and remained stable afterward. There was no influence of gender, weight, height, body mass index, and body surface area on t1/2 GE. Normal values for GE of solids measured with the (13) C-OBT using a standardized methodology were determined in healthy children. We propose to use this method and corresponding reference ranges to study GE of solids in children with gastrointestinal problems. © 2016 John Wiley & Sons Ltd.
Estimation of stress relaxation time for normal and abnormal breast phantoms using optical technique
NASA Astrophysics Data System (ADS)
Udayakumar, K.; Sujatha, N.
2015-03-01
Many of the early occurring micro-anomalies in breast may transform into a deadliest cancer tumor in future. Probability of curing early occurring abnormalities in breast is more if rightly identified. Even in mammogram, considered as a golden standard technique for breast imaging, it is hard to pick up early occurring changes in the breast tissue due to the difference in mechanical behavior of the normal and abnormal tissue when subjected to compression prior to x-ray or laser exposure. In this paper, an attempt has been made to estimate the stress relaxation time of normal and abnormal breast mimicking phantom using laser speckle image correlation. Phantoms mimicking normal breast is prepared and subjected to precise mechanical compression. The phantom is illuminated by a Helium Neon laser and by using a CCD camera, a sequence of strained phantom speckle images are captured and correlated by the image mean intensity value at specific time intervals. From the relation between mean intensity versus time, tissue stress relaxation time is quantified. Experiments were repeated for phantoms with increased stiffness mimicking abnormal tissue for similar ranges of applied loading. Results shows that phantom with more stiffness representing abnormal tissue shows uniform relaxation for varying load of the selected range, whereas phantom with less stiffness representing normal tissue shows irregular behavior for varying loadings in the given range.
Jopp, Eilin; Scheffler, Christiane; Hermanussen, Michael
2014-01-01
Screening is an important issue in medicine and is used to early identify unrecognised diseases in persons who are apparently in good health. Screening strongly relies on the concept of "normal values". Normal values are defined as values that are frequently observed in a population and usually range within certain statistical limits. Screening for obesity should start early as the prevalence of obesity consolidates already at early school age. Though widely practiced, measuring BMI is not the ultimate solution for detecting obesity. Children with high BMI may be "robust" in skeletal dimensions. Assessing skeletal robustness and in particularly assessing developmental tempo in adolescents are also important issues in health screening. Yet, in spite of the necessity of screening investigations, appropriate reference values are often missing. Meanwhile, new concepts of growth diagrams have been developed. Stage line diagrams are useful for tracking developmental processes over time. Functional data analyses have efficiently been used for analysing longitudinal growth in height and assessing the tempo of maturation. Convenient low-cost statistics have also been developed for generating synthetic national references.
[Hypothyreodism. From the latent functional disorder up to coma].
Hintze, G; Derwahl, M
2010-05-01
An autoimmune thyroiditis represents the main reason of hypothyroidism, defined as a lack of thyroid hormone. This autoimmune process results in destruction of functioning thyroid follicles. While subclinical or latent hypothyroidism is defined on the basis of laboratory values (an elevation of TSH with normal peripheral hormone levels), the typical signs and symptoms are associated with hypothyroidism. In about 80% of cases antibodies against thyroid peroxidase can be measured, but only in about 40-50% of cases antibodies against thyroglobulin are detectable. If hypothyrodism has been diagnosed, substitution with levothyroxine should be initiated, with the therapeutic goal to decrease TSH level to the lower normal range. In cases of subclinical hypothyroidism, levothyroxine medication should be started in patients with a high TSH value, positive antibodies and/or the typical ultrasound of autoimmune thyroiditis. However, substitution with levothyroxine in any case of elevated TSH values should be avoided.
Nakajima, Kenichi; Matsumoto, Naoya; Kasai, Tokuo; Matsuo, Shinro; Kiso, Keisuke; Okuda, Koichi
2016-04-01
As a 2-year project of the Japanese Society of Nuclear Medicine working group activity, normal myocardial imaging databases were accumulated and summarized. Stress-rest with gated and non-gated image sets were accumulated for myocardial perfusion imaging and could be used for perfusion defect scoring and normal left ventricular (LV) function analysis. For single-photon emission computed tomography (SPECT) with multi-focal collimator design, databases of supine and prone positions and computed tomography (CT)-based attenuation correction were created. The CT-based correction provided similar perfusion patterns between genders. In phase analysis of gated myocardial perfusion SPECT, a new approach for analyzing dyssynchrony, normal ranges of parameters for phase bandwidth, standard deviation and entropy were determined in four software programs. Although the results were not interchangeable, dependency on gender, ejection fraction and volumes were common characteristics of these parameters. Standardization of (123)I-MIBG sympathetic imaging was performed regarding heart-to-mediastinum ratio (HMR) using a calibration phantom method. The HMRs from any collimator types could be converted to the value with medium-energy comparable collimators. Appropriate quantification based on common normal databases and standard technology could play a pivotal role for clinical practice and researches.
NASA Astrophysics Data System (ADS)
Khachatryan, V.; Sirunyan, A. M.; Tumasyan, A.; Adam, W.; Asilar, E.; Bergauer, T.; Brandstetter, J.; Brondolin, E.; Dragicevic, M.; Erö, J.; Flechl, M.; Friedl, M.; Frühwirth, R.; Ghete, V. M.; Hartl, C.; Hörmann, N.; Hrubec, J.; Jeitler, M.; Knünz, V.; König, A.; Krammer, M.; Krätschmer, I.; Liko, D.; Matsushita, T.; Mikulec, I.; Rabady, D.; Rad, N.; Rahbaran, B.; Rohringer, H.; Schieck, J.; Schöfbeck, R.; Strauss, J.; Treberer-Treberspurg, W.; Waltenberger, W.; Wulz, C.-E.; Mossolov, V.; Shumeiko, N.; Suarez Gonzalez, J.; Alderweireldt, S.; Cornelis, T.; De Wolf, E. A.; Janssen, X.; Knutsson, A.; Lauwers, J.; Luyckx, S.; Van De Klundert, M.; Van Haevermaet, H.; Van Mechelen, P.; Van Remortel, N.; Van Spilbeeck, A.; Abu Zeid, S.; Blekman, F.; D'Hondt, J.; Daci, N.; De Bruyn, I.; Deroover, K.; Heracleous, N.; Keaveney, J.; Lowette, S.; Moreels, L.; Olbrechts, A.; Python, Q.; Strom, D.; Tavernier, S.; Van Doninck, W.; Van Mulders, P.; Van Onsem, G. P.; Van Parijs, I.; Barria, P.; Brun, H.; Caillol, C.; Clerbaux, B.; De Lentdecker, G.; Fasanella, G.; Favart, L.; Goldouzian, R.; Grebenyuk, A.; Karapostoli, G.; Lenzi, T.; Léonard, A.; Maerschalk, T.; Marinov, A.; Pernié, L.; Randle-conde, A.; Seva, T.; Vander Velde, C.; Vanlaer, P.; Yonamine, R.; Zenoni, F.; Zhang, F.; Beernaert, K.; Benucci, L.; Cimmino, A.; Crucy, S.; Dobur, D.; Fagot, A.; Garcia, G.; Gul, M.; Mccartin, J.; Ocampo Rios, A. A.; Poyraz, D.; Ryckbosch, D.; Salva, S.; Sigamani, M.; Tytgat, M.; Van Driessche, W.; Yazgan, E.; Zaganidis, N.; Basegmez, S.; Beluffi, C.; Bondu, O.; Brochet, S.; Bruno, G.; Caudron, A.; Ceard, L.; Delaere, C.; Favart, D.; Forthomme, L.; Giammanco, A.; Jafari, A.; Jez, P.; Komm, M.; Lemaitre, V.; Mertens, A.; Musich, M.; Nuttens, C.; Perrini, L.; Piotrzkowski, K.; Popov, A.; Quertenmont, L.; Selvaggi, M.; Vidal Marono, M.; Beliy, N.; Hammad, G. H.; Aldá Júnior, W. L.; Alves, F. L.; Alves, G. A.; Brito, L.; Correa Martins Junior, M.; Hamer, M.; Hensel, C.; Moraes, A.; Pol, M. E.; Rebello Teles, P.; Belchior Batista Das Chagas, E.; Carvalho, W.; Chinellato, J.; Custódio, A.; Da Costa, E. M.; De Jesus Damiao, D.; De Oliveira Martins, C.; Fonseca De Souza, S.; Huertas Guativa, L. M.; Malbouisson, H.; Matos Figueiredo, D.; Mora Herrera, C.; Mundim, L.; Nogima, H.; Prado Da Silva, W. L.; Santoro, A.; Sznajder, A.; Tonelli Manganote, E. J.; Vilela Pereira, A.; Ahuja, S.; Bernardes, C. A.; De Souza Santos, A.; Dogra, S.; Tomei, T. R. Fernandez Perez; Gregores, E. M.; Mercadante, P. G.; Moon, C. S.; Novaes, S. F.; Padula, Sandra S.; Romero Abad, D.; Ruiz Vargas, J. C.; Aleksandrov, A.; Hadjiiska, R.; Iaydjiev, P.; Rodozov, M.; Stoykova, S.; Sultanov, G.; Vutova, M.; Dimitrov, A.; Glushkov, I.; Litov, L.; Pavlov, B.; Petkov, P.; Ahmad, M.; Bian, J. G.; Chen, G. M.; Chen, H. S.; Chen, M.; Cheng, T.; Du, R.; Jiang, C. H.; Leggat, D.; Plestina, R.; Romeo, F.; Shaheen, S. M.; Spiezia, A.; Tao, J.; Wang, C.; Wang, Z.; Zhang, H.; Asawatangtrakuldee, C.; Ban, Y.; Li, Q.; Liu, S.; Mao, Y.; Qian, S. J.; Wang, D.; Xu, Z.; Avila, C.; Cabrera, A.; Chaparro Sierra, L. F.; Florez, C.; Gomez, J. P.; Gomez Moreno, B.; Sanabria, J. C.; Godinovic, N.; Lelas, D.; Puljak, I.; Ribeiro Cipriano, P. M.; Antunovic, Z.; Kovac, M.; Brigljevic, V.; Kadija, K.; Luetic, J.; Micanovic, S.; Sudic, L.; Attikis, A.; Mavromanolakis, G.; Mousa, J.; Nicolaou, C.; Ptochos, F.; Razis, P. A.; Rykaczewski, H.; Bodlak, M.; Finger, M.; Finger, M.; Abdelalim, A. A.; Awad, A.; Mahrous, A.; Radi, A.; Calpas, B.; Kadastik, M.; Murumaa, M.; Raidal, M.; Tiko, A.; Veelken, C.; Eerola, P.; Pekkanen, J.; Voutilainen, M.; Härkönen, J.; Karimäki, V.; Kinnunen, R.; Lampén, T.; Lassila-Perini, K.; Lehti, S.; Lindén, T.; Luukka, P.; Peltola, T.; Tuominiemi, J.; Tuovinen, E.; Wendland, L.; Talvitie, J.; Tuuva, T.; Besancon, M.; Couderc, F.; Dejardin, M.; Denegri, D.; Fabbro, B.; Faure, J. L.; Favaro, C.; Ferri, F.; Ganjour, S.; Givernaud, A.; Gras, P.; Hamel de Monchenault, G.; Jarry, P.; Locci, E.; Machet, M.; Malcles, J.; Rander, J.; Rosowsky, A.; Titov, M.; Zghiche, A.; Antropov, I.; Baffioni, S.; Beaudette, F.; Busson, P.; Cadamuro, L.; Chapon, E.; Charlot, C.; Davignon, O.; Filipovic, N.; Granier de Cassagnac, R.; Jo, M.; Lisniak, S.; Mastrolorenzo, L.; Miné, P.; Naranjo, I. N.; Nguyen, M.; Ochando, C.; Ortona, G.; Paganini, P.; Pigard, P.; Regnard, S.; Salerno, R.; Sauvan, J. B.; Sirois, Y.; Strebler, T.; Yilmaz, Y.; Zabi, A.; Agram, J.-L.; Andrea, J.; Aubin, A.; Bloch, D.; Brom, J.-M.; Buttignol, M.; Chabert, E. C.; Chanon, N.; Collard, C.; Conte, E.; Coubez, X.; Fontaine, J.-C.; Gelé, D.; Goerlach, U.; Goetzmann, C.; Le Bihan, A.-C.; Merlin, J. A.; Skovpen, K.; Van Hove, P.; Gadrat, S.; Beauceron, S.; Bernet, C.; Boudoul, G.; Bouvier, E.; Carrillo Montoya, C. A.; Chierici, R.; Contardo, D.; Courbon, B.; Depasse, P.; El Mamouni, H.; Fan, J.; Fay, J.; Gascon, S.; Gouzevitch, M.; Ille, B.; Lagarde, F.; Laktineh, I. B.; Lethuillier, M.; Mirabito, L.; Pequegnot, A. L.; Perries, S.; Ruiz Alvarez, J. D.; Sabes, D.; Sgandurra, L.; Sordini, V.; Vander Donckt, M.; Verdier, P.; Viret, S.; Toriashvili, T.; Tsamalaidze, Z.; Autermann, C.; Beranek, S.; Feld, L.; Heister, A.; Kiesel, M. K.; Klein, K.; Lipinski, M.; Ostapchuk, A.; Preuten, M.; Raupach, F.; Schael, S.; Schulte, J. F.; Verlage, T.; Weber, H.; Zhukov, V.; Ata, M.; Brodski, M.; Dietz-Laursonn, E.; Duchardt, D.; Endres, M.; Erdmann, M.; Erdweg, S.; Esch, T.; Fischer, R.; Güth, A.; Hebbeker, T.; Heidemann, C.; Hoepfner, K.; Knutzen, S.; Kreuzer, P.; Merschmeyer, M.; Meyer, A.; Millet, P.; Mukherjee, S.; Olschewski, M.; Padeken, K.; Papacz, P.; Pook, T.; Radziej, M.; Reithler, H.; Rieger, M.; Scheuch, F.; Sonnenschein, L.; Teyssier, D.; Thüer, S.; Cherepanov, V.; Erdogan, Y.; Flügge, G.; Geenen, H.; Geisler, M.; Hoehle, F.; Kargoll, B.; Kress, T.; Künsken, A.; Lingemann, J.; Nehrkorn, A.; Nowack, A.; Nugent, I. M.; Pistone, C.; Pooth, O.; Stahl, A.; Aldaya Martin, M.; Asin, I.; Bartosik, N.; Behnke, O.; Behrens, U.; Borras, K.; Burgmeier, A.; Campbell, A.; Contreras-Campana, C.; Costanza, F.; Diez Pardos, C.; Dolinska, G.; Dooling, S.; Dorland, T.; Eckerlin, G.; Eckstein, D.; Eichhorn, T.; Flucke, G.; Gallo, E.; Garay Garcia, J.; Geiser, A.; Gizhko, A.; Gunnellini, P.; Hauk, J.; Hempel, M.; Jung, H.; Kalogeropoulos, A.; Karacheban, O.; Kasemann, M.; Katsas, P.; Kieseler, J.; Kleinwort, C.; Korol, I.; Lange, W.; Leonard, J.; Lipka, K.; Lobanov, A.; Lohmann, W.; Mankel, R.; Melzer-Pellmann, I.-A.; Meyer, A. B.; Mittag, G.; Mnich, J.; Mussgiller, A.; Naumann-Emme, S.; Nayak, A.; Ntomari, E.; Perrey, H.; Pitzl, D.; Placakyte, R.; Raspereza, A.; Roland, B.; Sahin, M. Ö.; Saxena, P.; Schoerner-Sadenius, T.; Seitz, C.; Spannagel, S.; Trippkewitz, K. D.; Walsh, R.; Wissing, C.; Blobel, V.; Centis Vignali, M.; Draeger, A. R.; Erfle, J.; Garutti, E.; Goebel, K.; Gonzalez, D.; Görner, M.; Haller, J.; Hoffmann, M.; Höing, R. S.; Junkes, A.; Klanner, R.; Kogler, R.; Kovalchuk, N.; Lapsien, T.; Lenz, T.; Marchesini, I.; Marconi, D.; Meyer, M.; Nowatschin, D.; Ott, J.; Pantaleo, F.; Peiffer, T.; Perieanu, A.; Pietsch, N.; Poehlsen, J.; Rathjens, D.; Sander, C.; Scharf, C.; Schleper, P.; Schlieckau, E.; Schmidt, A.; Schumann, S.; Schwandt, J.; Sola, V.; Stadie, H.; Steinbrück, G.; Stober, F. M.; Tholen, H.; Troendle, D.; Usai, E.; Vanelderen, L.; Vanhoefer, A.; Vormwald, B.; Barth, C.; Baus, C.; Berger, J.; Böser, C.; Butz, E.; Chwalek, T.; Colombo, F.; De Boer, W.; Descroix, A.; Dierlamm, A.; Fink, S.; Frensch, F.; Friese, R.; Giffels, M.; Gilbert, A.; Haitz, D.; Hartmann, F.; Heindl, S. M.; Husemann, U.; Katkov, I.; Kornmayer, A.; Lobelle Pardo, P.; Maier, B.; Mildner, H.; Mozer, M. U.; Müller, T.; Müller, Th.; Plagge, M.; Quast, G.; Rabbertz, K.; Röcker, S.; Roscher, F.; Schröder, M.; Sieber, G.; Simonis, H. J.; Ulrich, R.; Wagner-Kuhr, J.; Wayand, S.; Weber, M.; Weiler, T.; Williamson, S.; Wöhrmann, C.; Wolf, R.; Anagnostou, G.; Daskalakis, G.; Geralis, T.; Giakoumopoulou, V. A.; Kyriakis, A.; Loukas, D.; Psallidas, A.; Topsis-Giotis, I.; Agapitos, A.; Kesisoglou, S.; Panagiotou, A.; Saoulidou, N.; Tziaferi, E.; Evangelou, I.; Flouris, G.; Foudas, C.; Kokkas, P.; Loukas, N.; Manthos, N.; Papadopoulos, I.; Paradas, E.; Strologas, J.; Bencze, G.; Hajdu, C.; Hazi, A.; Hidas, P.; Horvath, D.; Sikler, F.; Veszpremi, V.; Vesztergombi, G.; Zsigmond, A. J.; Beni, N.; Czellar, S.; Karancsi, J.; Molnar, J.; Szillasi, Z.; Bartók, M.; Makovec, A.; Raics, P.; Trocsanyi, Z. L.; Ujvari, B.; Choudhury, S.; Mal, P.; Mandal, K.; Sahoo, D. K.; Sahoo, N.; Swain, S. K.; Bansal, S.; Beri, S. B.; Bhatnagar, V.; Chawla, R.; Gupta, R.; Bhawandeep, U.; Kalsi, A. K.; Kaur, A.; Kaur, M.; Kumar, R.; Mehta, A.; Mittal, M.; Singh, J. B.; Walia, G.; Kumar, Ashok; Bhardwaj, A.; Choudhary, B. C.; Garg, R. B.; Malhotra, S.; Naimuddin, M.; Nishu, N.; Ranjan, K.; Sharma, R.; Sharma, V.; Bhattacharya, S.; Chatterjee, K.; Dey, S.; Dutta, S.; Majumdar, N.; Modak, A.; Mondal, K.; Mukhopadhyay, S.; Roy, A.; Roy, D.; Roy Chowdhury, S.; Sarkar, S.; Sharan, M.; Abdulsalam, A.; Chudasama, R.; Dutta, D.; Jha, V.; Kumar, V.; Mohanty, A. K.; Pant, L. M.; Shukla, P.; Topkar, A.; Aziz, T.; Banerjee, S.; Bhowmik, S.; Chatterjee, R. M.; Dewanjee, R. K.; Dugad, S.; Ganguly, S.; Ghosh, S.; Guchait, M.; Gurtu, A.; Jain, Sa.; Kole, G.; Kumar, S.; Mahakud, B.; Maity, M.; Majumder, G.; Mazumdar, K.; Mitra, S.; Mohanty, G. B.; Parida, B.; Sarkar, T.; Sur, N.; Sutar, B.; Wickramage, N.; Chauhan, S.; Dube, S.; Kapoor, A.; Kothekar, K.; Sharma, S.; Bakhshiansohi, H.; Behnamian, H.; Etesami, S. M.; Fahim, A.; Khakzad, M.; Mohammadi Najafabadi, M.; Naseri, M.; Paktinat Mehdiabadi, S.; Rezaei Hosseinabadi, F.; Safarzadeh, B.; Zeinali, M.; Felcini, M.; Grunewald, M.; Abbrescia, M.; Calabria, C.; Caputo, C.; Colaleo, A.; Creanza, D.; Cristella, L.; De Filippis, N.; De Palma, M.; Fiore, L.; Iaselli, G.; Maggi, G.; Maggi, M.; Miniello, G.; My, S.; Nuzzo, S.; Pompili, A.; Pugliese, G.; Radogna, R.; Ranieri, A.; Selvaggi, G.; Silvestris, L.; Venditti, R.; Abbiendi, G.; Battilana, C.; Benvenuti, A. C.; Bonacorsi, D.; Braibant-Giacomelli, S.; Brigliadori, L.; Campanini, R.; Capiluppi, P.; Castro, A.; Cavallo, F. R.; Chhibra, S. S.; Codispoti, G.; Cuffiani, M.; Dallavalle, G. M.; Fabbri, F.; Fanfani, A.; Fasanella, D.; Giacomelli, P.; Grandi, C.; Guiducci, L.; Marcellini, S.; Masetti, G.; Montanari, A.; Navarria, F. L.; Perrotta, A.; Rossi, A. M.; Rovelli, T.; Siroli, G. P.; Tosi, N.; Cappello, G.; Chiorboli, M.; Costa, S.; Di Mattia, A.; Giordano, F.; Potenza, R.; Tricomi, A.; Tuve, C.; Barbagli, G.; Ciulli, V.; Civinini, C.; D'Alessandro, R.; Focardi, E.; Gori, V.; Lenzi, P.; Meschini, M.; Paoletti, S.; Sguazzoni, G.; Viliani, L.; Benussi, L.; Bianco, S.; Fabbri, F.; Piccolo, D.; Primavera, F.; Calvelli, V.; Ferro, F.; Lo Vetere, M.; Monge, M. R.; Robutti, E.; Tosi, S.; Brianza, L.; Dinardo, M. E.; Fiorendi, S.; Gennai, S.; Gerosa, R.; Ghezzi, A.; Govoni, P.; Malvezzi, S.; Manzoni, R. A.; Marzocchi, B.; Menasce, D.; Moroni, L.; Paganoni, M.; Pedrini, D.; Ragazzi, S.; Redaelli, N.; Tabarelli de Fatis, T.; Buontempo, S.; Cavallo, N.; Di Guida, S.; Esposito, M.; Fabozzi, F.; Iorio, A. O. M.; Lanza, G.; Lista, L.; Meola, S.; Merola, M.; Paolucci, P.; Sciacca, C.; Thyssen, F.; Azzi, P.; Bacchetta, N.; Bellato, M.; Benato, L.; Boletti, A.; Branca, A.; Dall'Osso, M.; Dorigo, T.; Fantinel, S.; Fanzago, F.; Gonella, F.; Gozzelino, A.; Kanishchev, K.; Lacaprara, S.; Margoni, M.; Meneguzzo, A. T.; Montecassiano, F.; Passaseo, M.; Pazzini, J.; Pegoraro, M.; Pozzobon, N.; Ronchese, P.; Simonetto, F.; Torassa, E.; Tosi, M.; Ventura, S.; Zanetti, M.; Zotto, P.; Zucchetta, A.; Braghieri, A.; Magnani, A.; Montagna, P.; Ratti, S. P.; Re, V.; Riccardi, C.; Salvini, P.; Vai, I.; Vitulo, P.; Alunni Solestizi, L.; Bilei, G. M.; Ciangottini, D.; Fanò, L.; Lariccia, P.; Mantovani, G.; Menichelli, M.; Saha, A.; Santocchia, A.; Androsov, K.; Azzurri, P.; Bagliesi, G.; Bernardini, J.; Boccali, T.; Castaldi, R.; Ciocci, M. A.; Dell'Orso, R.; Donato, S.; Fedi, G.; Foà, L.; Giassi, A.; Grippo, M. T.; Ligabue, F.; Lomtadze, T.; Martini, L.; Messineo, A.; Palla, F.; Rizzi, A.; Savoy-Navarro, A.; Serban, A. T.; Spagnolo, P.; Tenchini, R.; Tonelli, G.; Venturi, A.; Verdini, P. G.; Barone, L.; Cavallari, F.; D'imperio, G.; Del Re, D.; Diemoz, M.; Gelli, S.; Jorda, C.; Longo, E.; Margaroli, F.; Meridiani, P.; Organtini, G.; Paramatti, R.; Preiato, F.; Rahatlou, S.; Rovelli, C.; Santanastasio, F.; Traczyk, P.; Amapane, N.; Arcidiacono, R.; Argiro, S.; Arneodo, M.; Bellan, R.; Biino, C.; Cartiglia, N.; Costa, M.; Covarelli, R.; Degano, A.; Demaria, N.; Finco, L.; Kiani, B.; Mariotti, C.; Maselli, S.; Migliore, E.; Monaco, V.; Monteil, E.; Obertino, M. M.; Pacher, L.; Pastrone, N.; Pelliccioni, M.; Pinna Angioni, G. L.; Ravera, F.; Romero, A.; Ruspa, M.; Sacchi, R.; Solano, A.; Staiano, A.; Belforte, S.; Candelise, V.; Casarsa, M.; Cossutti, F.; Della Ricca, G.; Gobbo, B.; La Licata, C.; Marone, M.; Schizzi, A.; Zanetti, A.; Kropivnitskaya, A.; Nam, S. K.; Kim, D. H.; Kim, G. N.; Kim, M. S.; Kong, D. J.; Lee, S.; Oh, Y. D.; Sakharov, A.; Son, D. C.; Brochero Cifuentes, J. A.; Kim, H.; Kim, T. J.; Song, S.; Cho, S.; Choi, S.; Go, Y.; Gyun, D.; Hong, B.; Kim, H.; Kim, Y.; Lee, B.; Lee, K.; Lee, K. S.; Lee, S.; Park, S. K.; Roh, Y.; Yoo, H. D.; Choi, M.; Kim, H.; Kim, J. H.; Lee, J. S. H.; Park, I. C.; Ryu, G.; Ryu, M. S.; Choi, Y.; Goh, J.; Kim, D.; Kwon, E.; Lee, J.; Yu, I.; Dudenas, V.; Juodagalvis, A.; Vaitkus, J.; Ahmed, I.; Ibrahim, Z. A.; Komaragiri, J. R.; Md Ali, M. A. B.; Mohamad Idris, F.; Wan Abdullah, W. A. T.; Yusli, M. N.; Zolkapli, Z.; Casimiro Linares, E.; Castilla-Valdez, H.; De La Cruz-Burelo, E.; Heredia-De La Cruz, I.; Hernandez-Almada, A.; Lopez-Fernandez, R.; Sanchez-Hernandez, A.; Carrillo Moreno, S.; Vazquez Valencia, F.; Pedraza, I.; Salazar Ibarguen, H. A.; Morelos Pineda, A.; Krofcheck, D.; Butler, P. H.; Ahmad, A.; Ahmad, M.; Hassan, Q.; Hoorani, H. R.; Khan, W. A.; Khurshid, T.; Shoaib, M.; Bialkowska, H.; Bluj, M.; Boimska, B.; Frueboes, T.; Górski, M.; Kazana, M.; Nawrocki, K.; Romanowska-Rybinska, K.; Szleper, M.; Zalewski, P.; Brona, G.; Bunkowski, K.; Byszuk, A.; Doroba, K.; Kalinowski, A.; Konecki, M.; Krolikowski, J.; Misiura, M.; Olszewski, M.; Walczak, M.; Bargassa, P.; Beirão Da Cruz E Silva, C.; Di Francesco, A.; Faccioli, P.; Ferreira Parracho, P. G.; Gallinaro, M.; Hollar, J.; Leonardo, N.; Lloret Iglesias, L.; Nguyen, F.; Rodrigues Antunes, J.; Seixas, J.; Toldaiev, O.; Vadruccio, D.; Varela, J.; Vischia, P.; Afanasiev, S.; Bunin, P.; Gavrilenko, M.; Golutvin, I.; Gorbunov, I.; Kamenev, A.; Karjavin, V.; Lanev, A.; Malakhov, A.; Matveev, V.; Moisenz, P.; Palichik, V.; Perelygin, V.; Shmatov, S.; Shulha, S.; Skatchkov, N.; Smirnov, V.; Zarubin, A.; Golovtsov, V.; Ivanov, Y.; Kim, V.; Kuznetsova, E.; Levchenko, P.; Murzin, V.; Oreshkin, V.; Smirnov, I.; Sulimov, V.; Uvarov, L.; Vavilov, S.; Vorobyev, A.; Andreev, Yu.; Dermenev, A.; Gninenko, S.; Golubev, N.; Karneyeu, A.; Kirsanov, M.; Krasnikov, N.; Pashenkov, A.; Tlisov, D.; Toropin, A.; Epshteyn, V.; Gavrilov, V.; Lychkovskaya, N.; Popov, V.; Pozdnyakov, I.; Safronov, G.; Spiridonov, A.; Vlasov, E.; Zhokin, A.; Bylinkin, A.; Chadeeva, M.; Danilov, M.; Andreev, V.; Azarkin, M.; Dremin, I.; Kirakosyan, M.; Leonidov, A.; Mesyats, G.; Rusakov, S. V.; Baskakov, A.; Belyaev, A.; Boos, E.; Ershov, A.; Gribushin, A.; Kaminskiy, A.; Kodolova, O.; Korotkikh, V.; Lokhtin, I.; Miagkov, I.; Obraztsov, S.; Petrushanko, S.; Savrin, V.; Snigirev, A.; Vardanyan, I.; Azhgirey, I.; Bayshev, I.; Bitioukov, S.; Kachanov, V.; Kalinin, A.; Konstantinov, D.; Krychkine, V.; Petrov, V.; Ryutin, R.; Sobol, A.; Tourtchanovitch, L.; Troshin, S.; Tyurin, N.; Uzunian, A.; Volkov, A.; Adzic, P.; Cirkovic, P.; Milosevic, J.; Rekovic, V.; Alcaraz Maestre, J.; Calvo, E.; Cerrada, M.; Chamizo Llatas, M.; Colino, N.; De La Cruz, B.; Delgado Peris, A.; Escalante Del Valle, A.; Fernandez Bedoya, C.; Fernández Ramos, J. P.; Flix, J.; Fouz, M. C.; Garcia-Abia, P.; Gonzalez Lopez, O.; Goy Lopez, S.; Hernandez, J. M.; Josa, M. I.; Navarro De Martino, E.; Pérez-Calero Yzquierdo, A.; Puerta Pelayo, J.; Quintario Olmeda, A.; Redondo, I.; Romero, L.; Santaolalla, J.; Soares, M. S.; Albajar, C.; de Trocóniz, J. F.; Missiroli, M.; Moran, D.; Cuevas, J.; Fernandez Menendez, J.; Folgueras, S.; Gonzalez Caballero, I.; Palencia Cortezon, E.; Vizan Garcia, J. M.; Cabrillo, I. J.; Calderon, A.; Castiñeiras De Saa, J. R.; De Castro Manzano, P.; Fernandez, M.; Garcia-Ferrero, J.; Gomez, G.; Lopez Virto, A.; Marco, J.; Marco, R.; Martinez Rivero, C.; Matorras, F.; Piedra Gomez, J.; Rodrigo, T.; Rodríguez-Marrero, A. Y.; Ruiz-Jimeno, A.; Scodellaro, L.; Trevisani, N.; Vila, I.; Vilar Cortabitarte, R.; Abbaneo, D.; Auffray, E.; Auzinger, G.; Bachtis, M.; Baillon, P.; Ball, A. H.; Barney, D.; Benaglia, A.; Bendavid, J.; Benhabib, L.; Berruti, G. M.; Bloch, P.; Bocci, A.; Bonato, A.; Botta, C.; Breuker, H.; Camporesi, T.; Castello, R.; Cerminara, G.; D'Alfonso, M.; d'Enterria, D.; Dabrowski, A.; Daponte, V.; David, A.; De Gruttola, M.; De Guio, F.; De Roeck, A.; De Visscher, S.; Di Marco, E.; Dobson, M.; Dordevic, M.; Dorney, B.; du Pree, T.; Duggan, D.; Dünser, M.; Dupont, N.; Elliott-Peisert, A.; Franzoni, G.; Fulcher, J.; Funk, W.; Gigi, D.; Gill, K.; Giordano, D.; Girone, M.; Glege, F.; Guida, R.; Gundacker, S.; Guthoff, M.; Hammer, J.; Harris, P.; Hegeman, J.; Innocente, V.; Janot, P.; Kirschenmann, H.; Kortelainen, M. J.; Kousouris, K.; Krajczar, K.; Lecoq, P.; Lourenço, C.; Lucchini, M. T.; Magini, N.; Malgeri, L.; Mannelli, M.; Martelli, A.; Masetti, L.; Meijers, F.; Mersi, S.; Meschi, E.; Moortgat, F.; Morovic, S.; Mulders, M.; Nemallapudi, M. V.; Neugebauer, H.; Orfanelli, S.; Orsini, L.; Pape, L.; Perez, E.; Peruzzi, M.; Petrilli, A.; Petrucciani, G.; Pfeiffer, A.; Pierini, M.; Piparo, D.; Racz, A.; Reis, T.; Rolandi, G.; Rovere, M.; Ruan, M.; Sakulin, H.; Schäfer, C.; Schwick, C.; Seidel, M.; Sharma, A.; Silva, P.; Simon, M.; Sphicas, P.; Steggemann, J.; Stieger, B.; Stoye, M.; Takahashi, Y.; Treille, D.; Triossi, A.; Tsirou, A.; Veres, G. I.; Wardle, N.; Wöhri, H. K.; Zagozdzinska, A.; Zeuner, W. D.; Bertl, W.; Deiters, K.; Erdmann, W.; Horisberger, R.; Ingram, Q.; Kaestli, H. C.; Kotlinski, D.; Langenegger, U.; Rohe, T.; Bachmair, F.; Bäni, L.; Bianchini, L.; Casal, B.; Dissertori, G.; Dittmar, M.; Donegá, M.; Eller, P.; Grab, C.; Heidegger, C.; Hits, D.; Hoss, J.; Kasieczka, G.; Lecomte, P.; Lustermann, W.; Mangano, B.; Marionneau, M.; Martinez Ruiz del Arbol, P.; Masciovecchio, M.; Meister, D.; Micheli, F.; Musella, P.; Nessi-Tedaldi, F.; Pandolfi, F.; Pata, J.; Pauss, F.; Perrozzi, L.; Quittnat, M.; Rossini, M.; Schönenberger, M.; Starodumov, A.; Takahashi, M.; Tavolaro, V. R.; Theofilatos, K.; Wallny, R.; Aarrestad, T. K.; Amsler, C.; Caminada, L.; Canelli, M. F.; Chiochia, V.; De Cosa, A.; Galloni, C.; Hinzmann, A.; Hreus, T.; Kilminster, B.; Lange, C.; Ngadiuba, J.; Pinna, D.; Rauco, G.; Robmann, P.; Salerno, D.; Yang, Y.; Cardaci, M.; Chen, K. H.; Doan, T. H.; Jain, Sh.; Khurana, R.; Konyushikhin, M.; Kuo, C. M.; Lin, W.; Lu, Y. J.; Pozdnyakov, A.; Yu, S. S.; Kumar, Arun; Chang, P.; Chang, Y. H.; Chang, Y. W.; Chao, Y.; Chen, K. F.; Chen, P. H.; Dietz, C.; Fiori, F.; Grundler, U.; Hou, W.-S.; Hsiung, Y.; Liu, Y. F.; Lu, R.-S.; Miñano Moya, M.; Petrakou, E.; Tsai, J. f.; Tzeng, Y. M.; Asavapibhop, B.; Kovitanggoon, K.; Singh, G.; Srimanobhas, N.; Suwonjandee, N.; Adiguzel, A.; Cerci, S.; Demiroglu, Z. S.; Dozen, C.; Dumanoglu, I.; Gecit, F. H.; Girgis, S.; Gokbulut, G.; Guler, Y.; Gurpinar, E.; Hos, I.; Kangal, E. E.; Kayis Topaksu, A.; Onengut, G.; Ozcan, M.; Ozdemir, K.; Ozturk, S.; Tali, B.; Topakli, H.; Zorbilmez, C.; Bilin, B.; Bilmis, S.; Isildak, B.; Karapinar, G.; Yalvac, M.; Zeyrek, M.; Gülmez, E.; Kaya, M.; Kaya, O.; Yetkin, E. A.; Yetkin, T.; Cakir, A.; Cankocak, K.; Sen, S.; Vardarlí, F. I.; Grynyov, B.; Levchuk, L.; Sorokin, P.; Aggleton, R.; Ball, F.; Beck, L.; Brooke, J. J.; Clement, E.; Cussans, D.; Flacher, H.; Goldstein, J.; Grimes, M.; Heath, G. P.; Heath, H. F.; Jacob, J.; Kreczko, L.; Lucas, C.; Meng, Z.; Newbold, D. M.; Paramesvaran, S.; Poll, A.; Sakuma, T.; Seif El Nasr-storey, S.; Senkin, S.; Smith, D.; Smith, V. J.; Belyaev, A.; Brew, C.; Brown, R. M.; Calligaris, L.; Cieri, D.; Cockerill, D. J. A.; Coughlan, J. A.; Harder, K.; Harper, S.; Olaiya, E.; Petyt, D.; Shepherd-Themistocleous, C. H.; Thea, A.; Tomalin, I. R.; Williams, T.; Worm, S. D.; Baber, M.; Bainbridge, R.; Buchmuller, O.; Bundock, A.; Burton, D.; Casasso, S.; Citron, M.; Colling, D.; Corpe, L.; Dauncey, P.; Davies, G.; De Wit, A.; Della Negra, M.; Dunne, P.; Elwood, A.; Futyan, D.; Hall, G.; Iles, G.; Lane, R.; Lucas, R.; Lyons, L.; Magnan, A.-M.; Malik, S.; Nash, J.; Nikitenko, A.; Pela, J.; Pesaresi, M.; Raymond, D. M.; Richards, A.; Rose, A.; Seez, C.; Tapper, A.; Uchida, K.; Vazquez Acosta, M.; Virdee, T.; Zenz, S. C.; Cole, J. E.; Hobson, P. R.; Khan, A.; Kyberd, P.; Leslie, D.; Reid, I. D.; Symonds, P.; Teodorescu, L.; Turner, M.; Borzou, A.; Call, K.; Dittmann, J.; Hatakeyama, K.; Liu, H.; Pastika, N.; Charaf, O.; Cooper, S. I.; Henderson, C.; Rumerio, P.; Arcaro, D.; Avetisyan, A.; Bose, T.; Gastler, D.; Rankin, D.; Richardson, C.; Rohlf, J.; Sulak, L.; Zou, D.; Alimena, J.; Berry, E.; Cutts, D.; Ferapontov, A.; Garabedian, A.; Hakala, J.; Heintz, U.; Jesus, O.; Laird, E.; Landsberg, G.; Mao, Z.; Narain, M.; Piperov, S.; Sagir, S.; Syarif, R.; Breedon, R.; Breto, G.; Calderon De La Barca Sanchez, M.; Chauhan, S.; Chertok, M.; Conway, J.; Conway, R.; Cox, P. T.; Erbacher, R.; Funk, G.; Gardner, M.; Ko, W.; Lander, R.; Mclean, C.; Mulhearn, M.; Pellett, D.; Pilot, J.; Ricci-Tam, F.; Shalhout, S.; Smith, J.; Squires, M.; Stolp, D.; Tripathi, M.; Wilbur, S.; Yohay, R.; Cousins, R.; Everaerts, P.; Florent, A.; Hauser, J.; Ignatenko, M.; Saltzberg, D.; Takasugi, E.; Valuev, V.; Weber, M.; Burt, K.; Clare, R.; Ellison, J.; Gary, J. W.; Hanson, G.; Heilman, J.; Ivova Paneva, M.; Jandir, P.; Kennedy, E.; Lacroix, F.; Long, O. R.; Malberti, M.; Olmedo Negrete, M.; Shrinivas, A.; Wei, H.; Wimpenny, S.; Yates, B. R.; Branson, J. G.; Cerati, G. B.; Cittolin, S.; D'Agnolo, R. T.; Derdzinski, M.; Holzner, A.; Kelley, R.; Klein, D.; Letts, J.; Macneill, I.; Olivito, D.; Padhi, S.; Pieri, M.; Sani, M.; Sharma, V.; Simon, S.; Tadel, M.; Vartak, A.; Wasserbaech, S.; Welke, C.; Würthwein, F.; Yagil, A.; Zevi Della Porta, G.; Bradmiller-Feld, J.; Campagnari, C.; Dishaw, A.; Dutta, V.; Flowers, K.; Franco Sevilla, M.; Geffert, P.; George, C.; Golf, F.; Gouskos, L.; Gran, J.; Incandela, J.; Mccoll, N.; Mullin, S. D.; Richman, J.; Stuart, D.; Suarez, I.; West, C.; Yoo, J.; Anderson, D.; Apresyan, A.; Bornheim, A.; Bunn, J.; Chen, Y.; Duarte, J.; Mott, A.; Newman, H. B.; Pena, C.; Spiropulu, M.; Vlimant, J. R.; Xie, S.; Zhu, R. Y.; Andrews, M. B.; Azzolini, V.; Calamba, A.; Carlson, B.; Ferguson, T.; Paulini, M.; Russ, J.; Sun, M.; Vogel, H.; Vorobiev, I.; Cumalat, J. P.; Ford, W. T.; Gaz, A.; Jensen, F.; Johnson, A.; Krohn, M.; Mulholland, T.; Nauenberg, U.; Stenson, K.; Wagner, S. R.; Alexander, J.; Chatterjee, A.; Chaves, J.; Chu, J.; Dittmer, S.; Eggert, N.; Mirman, N.; Nicolas Kaufman, G.; Patterson, J. R.; Rinkevicius, A.; Ryd, A.; Skinnari, L.; Soffi, L.; Sun, W.; Tan, S. M.; Teo, W. D.; Thom, J.; Thompson, J.; Tucker, J.; Weng, Y.; Wittich, P.; Abdullin, S.; Albrow, M.; Apollinari, G.; Banerjee, S.; Bauerdick, L. A. T.; Beretvas, A.; Berryhill, J.; Bhat, P. C.; Bolla, G.; Burkett, K.; Butler, J. N.; Cheung, H. W. K.; Chlebana, F.; Cihangir, S.; Elvira, V. D.; Fisk, I.; Freeman, J.; Gottschalk, E.; Gray, L.; Green, D.; Grünendahl, S.; Gutsche, O.; Hanlon, J.; Hare, D.; Harris, R. M.; Hasegawa, S.; Hirschauer, J.; Hu, Z.; Jayatilaka, B.; Jindariani, S.; Johnson, M.; Joshi, U.; Klima, B.; Kreis, B.; Lammel, S.; Linacre, J.; Lincoln, D.; Lipton, R.; Liu, T.; Lopes De Sá, R.; Lykken, J.; Maeshima, K.; Marraffino, J. M.; Maruyama, S.; Mason, D.; McBride, P.; Merkel, P.; Mrenna, S.; Nahn, S.; Newman-Holmes, C.; O'Dell, V.; Pedro, K.; Prokofyev, O.; Rakness, G.; Sexton-Kennedy, E.; Soha, A.; Spalding, W. J.; Spiegel, L.; Stoynev, S.; Strobbe, N.; Taylor, L.; Tkaczyk, S.; Tran, N. V.; Uplegger, L.; Vaandering, E. W.; Vernieri, C.; Verzocchi, M.; Vidal, R.; Wang, M.; Weber, H. A.; Whitbeck, A.; Acosta, D.; Avery, P.; Bortignon, P.; Bourilkov, D.; Carnes, A.; Carver, M.; Curry, D.; Das, S.; Field, R. D.; Furic, I. K.; Gleyzer, S. V.; Konigsberg, J.; Korytov, A.; Kotov, K.; Ma, P.; Matchev, K.; Mei, H.; Milenovic, P.; Mitselmakher, G.; Rank, D.; Rossin, R.; Shchutska, L.; Snowball, M.; Sperka, D.; Terentyev, N.; Thomas, L.; Wang, J.; Wang, S.; Yelton, J.; Hewamanage, S.; Linn, S.; Markowitz, P.; Martinez, G.; Rodriguez, J. L.; Ackert, A.; Adams, J. R.; Adams, T.; Askew, A.; Bein, S.; Bochenek, J.; Diamond, B.; Haas, J.; Hagopian, S.; Hagopian, V.; Johnson, K. F.; Khatiwada, A.; Prosper, H.; Weinberg, M.; Baarmand, M. M.; Bhopatkar, V.; Colafranceschi, S.; Hohlmann, M.; Kalakhety, H.; Noonan, D.; Roy, T.; Yumiceva, F.; Adams, M. R.; Apanasevich, L.; Berry, D.; Betts, R. R.; Bucinskaite, I.; Cavanaugh, R.; Evdokimov, O.; Gauthier, L.; Gerber, C. E.; Hofman, D. J.; Kurt, P.; O'Brien, C.; Sandoval Gonzalez, I. D.; Turner, P.; Varelas, N.; Wu, Z.; Zakaria, M.; Bilki, B.; Clarida, W.; Dilsiz, K.; Durgut, S.; Gandrajula, R. P.; Haytmyradov, M.; Khristenko, V.; Merlo, J.-P.; Mermerkaya, H.; Mestvirishvili, A.; Moeller, A.; Nachtman, J.; Ogul, H.; Onel, Y.; Ozok, F.; Penzo, A.; Snyder, C.; Tiras, E.; Wetzel, J.; Yi, K.; Anderson, I.; Barnett, B. A.; Blumenfeld, B.; Eminizer, N.; Fehling, D.; Feng, L.; Gritsan, A. V.; Maksimovic, P.; Martin, C.; Osherson, M.; Roskes, J.; Sady, A.; Sarica, U.; Swartz, M.; Xiao, M.; Xin, Y.; You, C.; Baringer, P.; Bean, A.; Benelli, G.; Bruner, C.; Kenny, R. P.; Majumder, D.; Malek, M.; Mcbrayer, W.; Murray, M.; Sanders, S.; Stringer, R.; Wang, Q.; Ivanov, A.; Kaadze, K.; Khalil, S.; Makouski, M.; Maravin, Y.; Mohammadi, A.; Saini, L. K.; Skhirtladze, N.; Toda, S.; Lange, D.; Rebassoo, F.; Wright, D.; Anelli, C.; Baden, A.; Baron, O.; Belloni, A.; Calvert, B.; Eno, S. C.; Ferraioli, C.; Gomez, J. A.; Hadley, N. J.; Jabeen, S.; Kellogg, R. G.; Kolberg, T.; Kunkle, J.; Lu, Y.; Mignerey, A. C.; Shin, Y. H.; Skuja, A.; Tonjes, M. B.; Tonwar, S. C.; Apyan, A.; Barbieri, R.; Baty, A.; Bierwagen, K.; Brandt, S.; Busza, W.; Cali, I. A.; Demiragli, Z.; Di Matteo, L.; Gomez Ceballos, G.; Goncharov, M.; Gulhan, D.; Iiyama, Y.; Innocenti, G. M.; Klute, M.; Kovalskyi, D.; Lai, Y. S.; Lee, Y.-J.; Levin, A.; Luckey, P. D.; Marini, A. C.; Mcginn, C.; Mironov, C.; Narayanan, S.; Niu, X.; Paus, C.; Roland, C.; Roland, G.; Salfeld-Nebgen, J.; Stephans, G. S. F.; Sumorok, K.; Varma, M.; Velicanu, D.; Veverka, J.; Wang, J.; Wang, T. W.; Wyslouch, B.; Yang, M.; Zhukova, V.; Dahmes, B.; Evans, A.; Finkel, A.; Gude, A.; Hansen, P.; Kalafut, S.; Kao, S. C.; Klapoetke, K.; Kubota, Y.; Lesko, Z.; Mans, J.; Nourbakhsh, S.; Ruckstuhl, N.; Rusack, R.; Tambe, N.; Turkewitz, J.; Acosta, J. G.; Oliveros, S.; Avdeeva, E.; Bartek, R.; Bloom, K.; Bose, S.; Claes, D. R.; Dominguez, A.; Fangmeier, C.; Gonzalez Suarez, R.; Kamalieddin, R.; Knowlton, D.; Kravchenko, I.; Meier, F.; Monroy, J.; Ratnikov, F.; Siado, J. E.; Snow, G. R.; Alyari, M.; Dolen, J.; George, J.; Godshalk, A.; Harrington, C.; Iashvili, I.; Kaisen, J.; Kharchilava, A.; Kumar, A.; Rappoccio, S.; Roozbahani, B.; Alverson, G.; Barberis, E.; Baumgartel, D.; Chasco, M.; Hortiangtham, A.; Massironi, A.; Morse, D. M.; Nash, D.; Orimoto, T.; Teixeira De Lima, R.; Trocino, D.; Wang, R.-J.; Wood, D.; Zhang, J.; Bhattacharya, S.; Hahn, K. A.; Kubik, A.; Low, J. F.; Mucia, N.; Odell, N.; Pollack, B.; Schmitt, M.; Sung, K.; Trovato, M.; Velasco, M.; Brinkerhoff, A.; Dev, N.; Hildreth, M.; Jessop, C.; Karmgard, D. J.; Kellams, N.; Lannon, K.; Marinelli, N.; Meng, F.; Mueller, C.; Musienko, Y.; Planer, M.; Reinsvold, A.; Ruchti, R.; Smith, G.; Taroni, S.; Valls, N.; Wayne, M.; Wolf, M.; Woodard, A.; Antonelli, L.; Brinson, J.; Bylsma, B.; Durkin, L. S.; Flowers, S.; Hart, A.; Hill, C.; Hughes, R.; Ji, W.; Ling, T. Y.; Liu, B.; Luo, W.; Puigh, D.; Rodenburg, M.; Winer, B. L.; Wulsin, H. W.; Driga, O.; Elmer, P.; Hardenbrook, J.; Hebda, P.; Koay, S. A.; Lujan, P.; Marlow, D.; Medvedeva, T.; Mooney, M.; Olsen, J.; Palmer, C.; Piroué, P.; Stickland, D.; Tully, C.; Zuranski, A.; Malik, S.; Barker, A.; Barnes, V. E.; Benedetti, D.; Bortoletto, D.; Gutay, L.; Jha, M. K.; Jones, M.; Jung, A. W.; Jung, K.; Kumar, A.; Miller, D. H.; Neumeister, N.; Radburn-Smith, B. C.; Shi, X.; Shipsey, I.; Silvers, D.; Sun, J.; Svyatkovskiy, A.; Wang, F.; Xie, W.; Xu, L.; Parashar, N.; Stupak, J.; Adair, A.; Akgun, B.; Chen, Z.; Ecklund, K. M.; Geurts, F. J. M.; Guilbaud, M.; Li, W.; Michlin, B.; Northup, M.; Padley, B. P.; Redjimi, R.; Roberts, J.; Rorie, J.; Tu, Z.; Zabel, J.; Betchart, B.; Bodek, A.; de Barbaro, P.; Demina, R.; Eshaq, Y.; Ferbel, T.; Galanti, M.; Garcia-Bellido, A.; Han, J.; Harel, A.; Hindrichs, O.; Khukhunaishvili, A.; Lo, K. H.; Petrillo, G.; Tan, P.; Verzetti, M.; Chou, J. P.; Contreras-Campana, E.; Ferencek, D.; Gershtein, Y.; Halkiadakis, E.; Heindl, M.; Hidas, D.; Hughes, E.; Kaplan, S.; Kunnawalkam Elayavalli, R.; Lath, A.; Nash, K.; Saka, H.; Salur, S.; Schnetzer, S.; Sheffield, D.; Somalwar, S.; Stone, R.; Thomas, S.; Thomassen, P.; Walker, M.; Foerster, M.; Riley, G.; Rose, K.; Spanier, S.; Thapa, K.; Bouhali, O.; Castaneda Hernandez, A.; Celik, A.; Dalchenko, M.; De Mattia, M.; Delgado, A.; Dildick, S.; Eusebi, R.; Gilmore, J.; Huang, T.; Kamon, T.; Krutelyov, V.; Mueller, R.; Osipenkov, I.; Pakhotin, Y.; Patel, R.; Perloff, A.; Rose, A.; Safonov, A.; Tatarinov, A.; Ulmer, K. A.; Akchurin, N.; Cowden, C.; Damgov, J.; Dragoiu, C.; Dudero, P. R.; Faulkner, J.; Kunori, S.; Lamichhane, K.; Lee, S. W.; Libeiro, T.; Undleeb, S.; Volobouev, I.; Appelt, E.; Delannoy, A. G.; Greene, S.; Gurrola, A.; Janjam, R.; Johns, W.; Maguire, C.; Mao, Y.; Melo, A.; Ni, H.; Sheldon, P.; Tuo, S.; Velkovska, J.; Xu, Q.; Arenton, M. W.; Cox, B.; Francis, B.; Goodell, J.; Hirosky, R.; Ledovskoy, A.; Li, H.; Lin, C.; Neu, C.; Sinthuprasith, T.; Sun, X.; Wang, Y.; Wolfe, E.; Wood, J.; Xia, F.; Clarke, C.; Harr, R.; Karchin, P. E.; Kottachchi Kankanamge Don, C.; Lamichhane, P.; Sturdy, J.; Belknap, D. A.; Carlsmith, D.; Cepeda, M.; Dasu, S.; Dodd, L.; Duric, S.; Gomber, B.; Grothe, M.; Herndon, M.; Hervé, A.; Klabbers, P.; Lanaro, A.; Levine, A.; Long, K.; Loveless, R.; Mohapatra, A.; Ojalvo, I.; Perry, T.; Pierro, G. A.; Polese, G.; Ruggles, T.; Sarangi, T.; Savin, A.; Sharma, A.; Smith, N.; Smith, W. H.; Taylor, D.; Verwilligen, P.; Woods, N.; CMS Collaboration
2017-07-01
Two-particle correlations in p Pb collisions at a nucleon-nucleon center-of-mass energy of 5.02 TeV are studied as a function of the pseudorapidity separation (Δ η ) of the particle pair at small relative azimuthal angle (|Δ ϕ |<π /3 ). The correlations are decomposed into a jet component that dominates the short-range correlations (|Δ η |<1 ), and a component that persists at large Δ η and may originate from collective behavior of the produced system. The events are classified in terms of the multiplicity of the produced particles. Finite azimuthal anisotropies are observed in high-multiplicity events. The second and third Fourier components of the particle-pair azimuthal correlations, V2 and V3, are extracted after subtraction of the jet component. The single-particle anisotropy parameters v2 and v3 are normalized by their laboratory frame midrapidity value and are studied as a function of ηc.m.. The normalized v2 distribution is found to be asymmetric about ηc.m.=0 , with smaller values observed at forward pseudorapidity, corresponding to the direction of the proton beam, while no significant pseudorapidity dependence is observed for the normalized v3 distribution within the statistical uncertainties.
Khachatryan, Vardan
2016-04-18
Two-particle correlations in pPb collisions at a nucleon-nucleon center-of-mass energy of 5.02 TeV are studied as a function of the pseudorapidity separation (Delta eta) of the particle pair at small relative azimuthal angle (abs(Delta phi)< pi/3). The correlations are decomposed into a jet component that dominates the short-range correlations (abs(Delta eta) < 1), and a component that persists at large Delta eta and may originate from collective behavior of the produced system. The events are classified in terms of the multiplicity of the produced particles. Finite azimuthal anisotropies are observed in high-multiplicity events. The second and third Fourier components ofmore » the particle-pair azimuthal correlations, V[2] and V[3], are extracted after subtraction of the jet component. The single-particle anisotropy parameters v[2] and v[3] are normalized by their lab frame mid-rapidity value and are studied as a function of eta[cm]. The normalized v[2] distribution is found to be asymmetric about eta[cm] = 0, with smaller values observed at forward pseudorapidity, corresponding to the direction of the proton beam, while no significant pseudorapidity dependence is observed for the normalized v[3] distribution within the statistical uncertainties.« less
USDA-ARS?s Scientific Manuscript database
A series of tests were conducted to determine residual efficacy of pyrethrin+methoprene aerosol to manage larvae of selected stored product insects. Efficacy was assessed through emergence of morphologically-normal adults and through a quantitative developmental index with values ranging from 1, for...
Binaural Loudness Summation in the Hearing Impaired.
ERIC Educational Resources Information Center
Hawkins, David B.; And Others
1987-01-01
Binaural loudness summation was measured using three different paradigms with 10 normally hearing and 20 bilaterally symmetrical high-frequency sensorineural hearing loss subjects. Binaural summation increased with presentation level using the loudness matching procedure, with values in the 6-10 dB range. Summation decreased with level using the…
Gaur, Sonia; Harmon, Stephanie; Rosenblum, Lauren; Greer, Matthew D; Mehralivand, Sherif; Coskun, Mehmet; Merino, Maria J; Wood, Bradford J; Shih, Joanna H; Pinto, Peter A; Choyke, Peter L; Turkbey, Baris
2018-05-07
The purposes of this study were to assess correlation of apparent diffusion coefficient (ADC) and normalized ADC (ratio of tumor to nontumor tissue) with the Prostate Imaging Reporting and Data System version 2 (PI-RADSv2) and updated International Society of Urological Pathology (ISUP) categories and to determine how to optimally use ADC metrics for objective assistance in categorizing lesions within PI-RADSv2 guidelines. In this retrospective study, 100 patients (median age, 62 years; range, 44-75 years; prostate-specific antigen level, 7.18 ng/mL; range, 1.70-84.56 ng/mL) underwent 3-T multiparametric MRI of the prostate with an endorectal coil. Mean ADC was extracted from ROIs based on subsequent prostatectomy specimens. Histopathologic analysis revealed 172 lesions (113 peripheral, 59 transition zone). Two radiologists blinded to histopathologic outcome assigned PI-RADSv2 categories. Kendall tau was used to correlate ADC metrics with PI-RADSv2 and ISUP categories. ROC curves were used to assess the utility of ADC metrics in differentiating each reader's PI-RADSv2 DWI category 4 or 5 assessment in the whole prostate and by zone. ADC metrics negatively correlated with ISUP category in the whole prostate (ADC, τ = -0.21, p = 0.0002; normalized ADC, τ = -0.21, p = 0.0001). Moderate negative correlation was found in expert PI-RADSv2 DWI categories (ADC, τ = -0.34; normalized ADC, τ = -0.31; each p < 0.0001) maintained across zones. In the whole prostate, AUCs of ADC and normalized ADC were 87% and 82% for predicting expert PI-RADSv2 DWI category 4 or 5. A derived optimal cutoff ADC less than 1061 and normalized ADC less than 0.65 achieved positive predictive values of 83% and 84% for correct classification of PI-RADSv2 DWI category 4 or 5 by an expert reader. Consistent relations and predictive values were found by an independent novice reader. ADC and normalized ADC inversely correlate with PI-RADSv2 and ISUP categories and can serve as quantitative metrics to assist with assigning PI-RADSv2 DWI category 4 or 5.
Restricted numerical range: A versatile tool in the theory of quantum information
NASA Astrophysics Data System (ADS)
Gawron, Piotr; Puchała, Zbigniew; Miszczak, Jarosław Adam; Skowronek, Łukasz; Życzkowski, Karol
2010-10-01
Numerical range of a Hermitian operator X is defined as the set of all possible expectation values of this observable among a normalized quantum state. We analyze a modification of this definition in which the expectation value is taken among a certain subset of the set of all quantum states. One considers, for instance, the set of real states, the set of product states, separable states, or the set of maximally entangled states. We show exemplary applications of these algebraic tools in the theory of quantum information: analysis of k-positive maps and entanglement witnesses, as well as study of the minimal output entropy of a quantum channel. Product numerical range of a unitary operator is used to solve the problem of local distinguishability of a family of two unitary gates.
Measurement of four tumor marker antigens in the sera of pregnant women.
Cheli, C D; Morris, D L; Neaman, I E; Dai, J; Allard, W J; Yeung, K K
1999-01-01
We sought to determine the maternal serum levels of four tumor-associated antigens during the three trimesters of pregnancy in healthy women. CEA, CA 228, CA 15-3, and Her2/neu oncogene product p105 assay values were determined for 90 healthy pregnant women during the three trimesters of pregnancy at five participating evaluation sites. Results were compared to means and cut-off values determined for healthy nonpregnant women. Differences in assay values in the 1st and 3rd trimester were analyzed for statistical significance (Student's t-test). CEA, CA 228 and CA 15-3 assay values in general were found to be within the normal range. CA 15-3 and Her2/neu p105 serum assay values were above the cut-off (3.3% and 8.2%, respectively) and were significantly elevated in the 3rd trimester as compared to the 1st trimester of pregnancy (P < 0.05 and P < 0.001, respectively). CEA and CA 228 may be of potential value in monitoring pregnant women with malignant disease. Normal elevations in 3rd trimester serum Her2/neu p105 and CA 15-3 assay values should be considered when monitoring a pregnant patient with malignant disease.
Furtner, J; Schöpf, V; Schewzow, K; Kasprian, G; Weber, M; Woitek, R; Asenbaum, U; Preusser, M; Marosi, C; Hainfellner, J A; Widhalm, G; Wolfsberger, S; Prayer, D
2014-03-01
Pulsed arterial spin-labeling is a noninvasive MR imaging perfusion method performed with the use of water in the arterial blood as an endogenous contrast agent. The purpose of this study was to determine the inversion time with the largest difference in normalized intratumoral signal intensity between high-grade and low-grade astrocytomas. Thirty-three patients with gliomas, histologically classified as low-grade (n = 7) or high-grade astrocytomas (n = 26) according to the World Health Organization brain tumor classification, were included. A 3T MR scanner was used to perform pulsed arterial spin-labeling measurements at 8 different inversion times (370 ms, 614 ms, 864 ms, 1114 ms, 1364 ms, 1614 ms, 1864 ms, and 2114 ms). Normalized intratumoral signal intensity was calculated, which was defined by the signal intensity ratio of the tumor and the contralateral normal brain tissue for all fixed inversion times. A 3-way mixed ANOVA was used to reveal potential differences in the normalized vascular intratumoral signal intensity between high-grade and low-grade astrocytomas. The difference in normalized vascular intratumoral signal intensity between high-grade and low-grade astrocytomas obtained the most statistically significant results at 370 ms (P = .003, other P values ranged from .012-.955). The inversion time by which to differentiate high-grade and low-grade astrocytomas by use of normalized vascular intratumoral signal intensity was 370 ms in our study. The normalized vascular intratumoral signal intensity values at this inversion time mainly reflect the labeled intra-arterial blood bolus and therefore could be referred to as normalized vascular intratumoral signal intensity. Our data indicate that the use of normalized vascular intratumoral signal intensity values allows differentiation between low-grade and high-grade astrocytomas and thus may serve as a new, noninvasive marker for astrocytoma grading.
Integrating models that depend on variable data
NASA Astrophysics Data System (ADS)
Banks, A. T.; Hill, M. C.
2016-12-01
Models of human-Earth systems are often developed with the goal of predicting the behavior of one or more dependent variables from multiple independent variables, processes, and parameters. Often dependent variable values range over many orders of magnitude, which complicates evaluation of the fit of the dependent variable values to observations. Many metrics and optimization methods have been proposed to address dependent variable variability, with little consensus being achieved. In this work, we evaluate two such methods: log transformation (based on the dependent variable being log-normally distributed with a constant variance) and error-based weighting (based on a multi-normal distribution with variances that tend to increase as the dependent variable value increases). Error-based weighting has the advantage of encouraging model users to carefully consider data errors, such as measurement and epistemic errors, while log-transformations can be a black box for typical users. Placing the log-transformation into the statistical perspective of error-based weighting has not formerly been considered, to the best of our knowledge. To make the evaluation as clear and reproducible as possible, we use multiple linear regression (MLR). Simulations are conducted with MatLab. The example represents stream transport of nitrogen with up to eight independent variables. The single dependent variable in our example has values that range over 4 orders of magnitude. Results are applicable to any problem for which individual or multiple data types produce a large range of dependent variable values. For this problem, the log transformation produced good model fit, while some formulations of error-based weighting worked poorly. Results support previous suggestions fthat error-based weighting derived from a constant coefficient of variation overemphasizes low values and degrades model fit to high values. Applying larger weights to the high values is inconsistent with the log-transformation. Greater consistency is obtained by imposing smaller (by up to a factor of 1/35) weights on the smaller dependent-variable values. From an error-based perspective, the small weights are consistent with large standard deviations. This work considers the consequences of these two common ways of addressing variable data.
Yang, Pei-Yin; Wu, Joung-Liang; Yeh, Guang-Perng; Tsung-Che Hsieh, Charles
2012-09-01
To evaluate the normal range of the fetal nasal bone length (NBL) in Taiwanese women using three-dimensional (3D) ultrasound, and compare the NBL of normal fetuses with Down syndrome to determine its significance in screening for trisomy 21. A total of 102 consecutive fetuses and another 7 fetuses with trisomy 21, determined by karyotyping at 15-22 weeks' gestation, were evaluated with 3D ultrasound before amniocentesis at Changhua Christian Hospital between November 2003 and April 2004. The normal range for NBL in the second trimester in the Taiwanese population was investigated, and a linear relationship with gestational age was noted. The NBL increased with advancing gestational age (NBL in cm=0.0264×gestational age in weeks -0.042 (R(2)=0.2416). The median of the biparietal diameter/nasal bone length ratio had a stable value which tended to change minimally between 15 and 22 weeks of gestation. Chromosomally normal fetuses had statistically longer nasal bones than fetuses with Down syndrome (p=0.014). We present a reference range for 3D ultrasound measurement of the fetal NBL. A short nasal bone at 15 to 22 weeks is associated with a high risk of trisomy 21. Copyright © 2012. Published by Elsevier B.V.
Słonina, Dorota; Biesaga, Beata; Swakoń, Jan; Kabat, Damian; Grzanka, Leszek; Ptaszkiewicz, Marta; Sowa, Urszula
2014-11-01
The aim of the study was to determine the relative biological effectiveness (RBE) of a 60-MeV proton radiotherapy beam at the Institute of Nuclear Physics, Polish Academy of Sciences (IFJ PAN) in Kraków, the first one to operate in Poland. RBE was assessed at the surviving fractions (SFs) of 0.01, 0.1, and 0.37, for normal human fibroblasts from three cancer patients. The cells were irradiated near the Bragg peak of the pristine beam and at three depths within a 28.4-mm spread-out Bragg peak (SOBP). Reference radiation was provided by 6-MV X-rays. The mean RBE value at SF = 0.01 for fibroblasts irradiated near the Bragg peak of pristine beam ranged between 1.06 and 1.15. The mean RBE values at SF = 0.01 for these cells exposed at depths of 2, 15, and 27 mm of the SOBP ranged between 0.95-1.00, 0.97-1.02, and 1.05-1.11, respectively. A trend was observed for RBE values to increase with survival level and with depth in the SOBP: at SF = 0.37 and at the depth of 27 mm, RBE values attained their maximum (1.19-1.24). The RBE values estimated at SF = 0.01 using normal human fibroblasts for the 60-MeV proton radiotherapy beam at the IFJ PAN in Kraków are close to values of 1.0 and 1.1, used in clinical practice.
Li, Heheng; Luo, Liangping; Huang, Li
2011-02-01
The present paper is aimed to study the fractal spectrum of the cerebral computerized tomography in 158 normal infants of different age groups, based on the calculation of chaotic theory. The distribution range of neonatal period was 1.88-1.90 (mean = 1.8913 +/- 0.0064); It reached a stable condition at the level of 1.89-1.90 during 1-12 months old (mean = 1.8927 +/- 0.0045); The normal range of 1-2 years old infants was 1.86-1.90 (mean = 1.8863 +/- 4 0.0085); It kept the invariance of the quantitative value among 1.88-1.91(mean = 1.8958 +/- 0.0083) during 2-3 years of age. ANOVA indicated there's no significant difference between boys and girls (F = 0.243, P > 0.05), but the difference of age groups was significant (F = 8.947, P < 0.001). The fractal dimension of cerebral computerized tomography in normal infants computed by box methods was maintained at an efficient stability from 1.86 to 1.91. It indicated that there exit some attractor modes in pediatric brain development.
The Influence of Normalization Weight in Population Pharmacokinetic Covariate Models.
Goulooze, Sebastiaan C; Völler, Swantje; Välitalo, Pyry A J; Calvier, Elisa A M; Aarons, Leon; Krekels, Elke H J; Knibbe, Catherijne A J
2018-03-23
In covariate (sub)models of population pharmacokinetic models, most covariates are normalized to the median value; however, for body weight, normalization to 70 kg or 1 kg is often applied. In this article, we illustrate the impact of normalization weight on the precision of population clearance (CL pop ) parameter estimates. The influence of normalization weight (70, 1 kg or median weight) on the precision of the CL pop estimate, expressed as relative standard error (RSE), was illustrated using data from a pharmacokinetic study in neonates with a median weight of 2.7 kg. In addition, a simulation study was performed to show the impact of normalization to 70 kg in pharmacokinetic studies with paediatric or obese patients. The RSE of the CL pop parameter estimate in the neonatal dataset was lowest with normalization to median weight (8.1%), compared with normalization to 1 kg (10.5%) or 70 kg (48.8%). Typical clearance (CL) predictions were independent of the normalization weight used. Simulations showed that the increase in RSE of the CL pop estimate with 70 kg normalization was highest in studies with a narrow weight range and a geometric mean weight away from 70 kg. When, instead of normalizing with median weight, a weight outside the observed range is used, the RSE of the CL pop estimate will be inflated, and should therefore not be used for model selection. Instead, established mathematical principles can be used to calculate the RSE of the typical CL (CL TV ) at a relevant weight to evaluate the precision of CL predictions.
Quantitative CT characterization of pediatric lung development using routine clinical imaging
Stein, Jill M.; Walkup, Laura L.; Brody, Alan S.; Fleck, Robert J.
2016-01-01
Background The use of quantitative CT analysis in children is limited by lack of normal values of lung parenchymal attenuation. These characteristics are important because normal lung development yields significant parenchymal attenuation changes as children age. Objective To perform quantitative characterization of normal pediatric lung parenchymal X-ray CT attenuation under routine clinical conditions in order to establish a baseline comparison to that seen in pathological lung conditions. Materials and methods We conducted a retrospective query of normal CT chest examinations in children ages 0–7 years from 2004 to 2014 using standard clinical protocol. During these examinations semi-automated lung parenchymal segmentation was performed to measure lung volume and mean lung attenuation. Results We analyzed 42 CT examinations in 39 children, ages 3 days to 83 months (mean ± standard deviation [SD] = 42±27 months). Lung volume ranged 0.10–1.72 liters (L). Mean lung attenuation was much higher in children younger than 12 months, with values as high as −380 Hounsfield units (HU) in neonates (lung volume 0.10 L). Lung volume decreased to approximately −650 HU by age 2 years (lung volume 0.47 L), with subsequently slower exponential decrease toward a relatively constant value of −860 HU as age and lung volume increased. Conclusion Normal lung parenchymal X-ray CT attenuation decreases with increasing lung volume and age; lung attenuation decreases rapidly in the first 2 years of age and more slowly thereafter. This change in normal lung attenuation should be taken into account as quantitative CT methods are translated to pediatric pulmonary imaging. PMID:27576458
Age-Related Changes and Reference Values of Bicaudate Ratio and Sagittal Brainstem Diameters on MRI.
Garbade, Sven F; Boy, Nikolas; Heringer, Jana; Kölker, Stefan; Harting, Inga
2018-06-05
Cranial magnetic resonance imaging (MRI) plays an important role in the diagnosis of neurometabolic diseases, and, in addition, temporal patterns of signal and volume changes allow insight into the underlying pathogenesis. While assessment of volume changes by visual inspection is subjective, volumetric approaches are often not feasible with rare neurometabolic diseases, where MRIs are often acquired with different scanners and protocols. Linear surrogate parameters of brain volume, for example, the bicaudate ratio, present a robust alternative that can be derived from standard imaging sequences. Due to the continuing postnatal brain and skull development and later brain involution, it is, however, necessary to compare patient values with age age-adapted normal values.In this article, we present age-dependent normal values derived from 993 standard scans of patients with normal MRI findings (age range: 0-80 years; mean = 19.9; median = 12.8 years) for bicaudate ratio as a measure of global supratentorial volume, as well as the maximal anteroposterior diameters of mesencephalon, pons, and medulla oblongata as parameters of brainstem volume. The provided data allow quantitative, objective assessment of brain volume changes instead of the usually performed visual and therefore subjective assessment. Georg Thieme Verlag KG Stuttgart · New York.
Radiation damage and annealing in large area n+/p/p+ GaAs shallow homojunction solar cells
NASA Technical Reports Server (NTRS)
Flood, D. J.; Brinker, D. J.; Swartz, C. K.; Hart, R. E., Jr.; Fan, J. C. C.
1982-01-01
Annealing of radiation damage was observed for the first time in VPE-grown, 2- by 2-cm, n+/p/p+ GaAs shallow homojunction solar cells. Electrical performance of several cells was determined as a function of 1-MeV electron fluence in the range of 10 to the 13th power to 10 to the 15th power e-/sq cm and as a function of thermal annealing time at various temperatures. Degradation of normalized power output after a fluence of 10 to the 15th power 1-MeV electrons/sq cm ranged from a low of 24 to 31 percent of initial maximum power. Normalized short circuit current degradation was limited to the range from 10 to 19 percent of preirradiated values. Thermal annealing was carried out in a flowing nitrogen gas ambient, with annealing temperatures spanning the range from 125 to 200 C. Substantial recovery of short circuit current was observed at temperatures as low as 175 C. In one case improvement by as much as 10 percent of the postirradiated value was observed. The key features of these cells are their extremely thin emitter layers (approxmately 0.05 micrometers), the absence of any Al sub xGd sub 1-x As passivating window layer, and their fabrication by vapor phase epitaxy.
NASA Technical Reports Server (NTRS)
Morris, R. V.; Gose, W. A.
1976-01-01
Ferromagnetic resonance and static magnetic measurements were made on 131 samples from core 60009/60010 and on 40 samples from section 60003 of the Apollo 16 deep drill core. These studies provided depth profiles for composition, in terms of the concentration of FeO, and relative surface exposure age (or maturity), in terms of the values of the specific FMR intensity normalized to the FeO content. For core 60009/60010, the concentration of FeO ranged from about 1.6 wt.% to 5.8 wt.% with a mean value of 4.6 wt.% and the maturity ranged from immature to mature with most of the soils being submature. A systematic decrease in maturity from the lunar surface to a depth of about 12.5 cm was observed in core section 60010. For core section 60003, the concentration of FeO ranged from about 5.2 wt.% to 7.5 wt.% with a mean value of 6.4 wt.% and the maturity ranged from submature to mature with most of the soils being mature.
Fox, Aaron S; Bonacci, Jason; McLean, Scott G; Spittle, Michael; Saunders, Natalie
2014-06-01
It has been proposed that the performance of athletic tasks where normal motion is exceeded has the potential to damage the anterior cruciate ligament (ACL). Determining the expected or 'normal' kinematic profile of athletic tasks commonly used to assess ACL injury risk can provide an evidence base for the identification of abnormal or anomalous task performances in a laboratory setting. The objective was to conduct a systematic review of studies examining lower limb kinematics of females during drop landing, drop vertical jump, and side-step cutting tasks, to determine 'normal' ranges for hip and knee joint kinematic variables. An electronic database search was conducted on the SPORTDiscus(TM), MEDLINE, AMED and CINAHL (January 1980-August 2013) databases using a combination of relevant keywords. Studies identified as potentially relevant were independently examined by two reviewers for inclusion. Where consensus could not be reached, a third reviewer was consulted. Original research articles that examined three-dimensional hip and knee kinematics of female subjects during the athletic tasks of interest were included for review. Articles were excluded if subjects had a history of lower back or lower limb joint injury or isolated data from the female cohort could not be extracted. Two reviewers independently assessed the quality of included studies. Data on subject characteristics, the athletic task performed, and kinematic data were extracted from included studies. Studies were categorised according to the athletic task being examined and each study allocated a weight within categories based on the number of subjects assessed. Extracted data were used to calculate the weighted means and standard deviations for hip and knee kinematics (initial contact and peak values). 'Normal' motion was classified as the weighted mean plus/minus one standard deviation. Of 2,920 citations, a total of 159 articles were identified as potentially relevant, with 29 meeting all inclusion/exclusion criteria. Due to the limited number of studies available examining double-leg drop landings and single-leg drop vertical jumps, insufficient data was available to include these tasks in the review. Therefore, a total of 25 articles were included. From the included studies, 'normal' ranges were calculated for the kinematic variables of interest across the athletic tasks examined. Joint forces and other additional elements play a role in ACL injuries, therefore, focusing solely on lower limb kinematics in classifying injury risk may not encapsulate all relevant factors. Insufficient data resulted in no normal ranges being calculated for double-leg drop land and single-leg drop vertical jump tasks. No included study examined hip internal/external rotation during single-leg drop landings, therefore ranges for this kinematic variable could not be determined. Variation in data between studies resulted in wide normal ranges being observed across certain kinematic variables. The ranges calculated in this review provide evidence-based values that can be used to identify abnormal or anomalous athletic task performances on a multi-planar scale. This may be useful in identifying neuromuscular factors or specific muscular recruitment strategies that contribute to ACL injury risk.
NASA Technical Reports Server (NTRS)
Miranda, F. A.; Gordon, W. L.; Bhasin, K. B.; Heinen, V. O.; Warner, J. D.; Valco, G. J.
1989-01-01
Millimeter wave transmission measurements through YBa2Cu3O(7-delta) thin films on MgO, ZrO2 and LaAlO3 substrates, are reported. The films (approx. 1 micron) were deposited by sequential evaporation and laser ablation techniques. Transition temperatures T sub c, ranging from 89.7 K for the Laser Ablated film on LaAlO3 to approximately 72 K for the sequentially evaporated film on MgO, were obtained. The values of the real and imaginary parts of the complex conductivity, sigma 1 and sigma 2, are obtained from the transmission data, assuming a two fluid model. The BCS approach is used to calculate values for an effective energy gap from the obtained values of sigma sub 1. A range of gap values from 2 DELTA o/K sub B T sub c = 4.19 to 4.35 was obtained. The magnetic penetration depth is evaluated from the deduced values of sigma 2. These results are discussed together with the frequency dependence of the normalized transmission amplitude, P/P sub c, below and above T sub c.
Handling of induced hypercalcaemia in hyperthyroidism
Lim, P.; Jacob, E.; Khoo, O. T.
1969-01-01
The mean serum calcium of 13 hyperthyroid patients was found to be significantly higher than that of controls matched for sex and age, though none of the patients' values were outside the normal range. Nevertheless, these patients responded very promptly to hypercalcaemia (induced by an intravenous calcium load), and their serum calcium returned to normal much more rapidly compared with the matched controls. There was also increased retention of intravenous calcium load, possibly owing to increased calcitonin production. Calcium infusion may be useful in treating bone diseases in which increased bone resorption exceeds bone accretion. PMID:5354875
Longitudinal Stream Profile Morphology and Patterns of Knickpoint Propagation in the Bighorn Range
NASA Astrophysics Data System (ADS)
Safran, E. B.; Anderson, R. S.; Riihimaki, C. A.; Armstrong, J.
2005-12-01
The northern U. S. Rocky Mountains and the adjacent sedimentary basins are in a transient state of response to regional, Late Cenozoic exhumation. Assembling the history of landscape change there requires interpreting the morphology and genesis of transient landforms such as knickpoints in longitudinal stream profiles. We used concavity and normalized channel steepness indices to quantify the longitudinal profile morphology of >75 streams draining the east side of the Bighorn Range and the adjacent Powder River Basin. Our analyses show that individual units in the range-margin sedimentary cover rock exert a strong influence on longitudinal profile morphology. In the Tongue River and Crazy Woman Creek drainages, more than 50% of the streams examined had knickpoints localized within a resistant, siliceous dolomite. Knickpoints on most streams with drainage areas greater than ~100 km2 at the range front have migrated headward into the gneissic and plutonic core of the range. In the Clear Creek drainage, where the lateral extent of sedimentary cover rock is more restricted than in the adjacent drainages, knickpoints do not align with any particular unit. River profiles in the Powder River Basin beyond 10-20 km from the range front exhibit concavities of ~0.3-0.6 and normalized channel steepness indices of 40-60 (using 0.45 as a reference concavity). All profiles analyzed that extend into the mountain range exhibit at least one reach with exceptionally high (>2) concavity and relatively high (100-600) normalized channel steepness index, highlighting zones of transient adjustment to local base-level drop in the basin. Headwater reaches of range-draining streams exhibit variable but moderate values of concavity (0.15-0.9) and normalized channel steepness index (20-100). The varied morphology of these reaches reflects their passage across a relict surface of low relief but also the effects of glaciation and/or the signature of the narrow summit spine that caps the range.
Missing value imputation strategies for metabolomics data.
Armitage, Emily Grace; Godzien, Joanna; Alonso-Herranz, Vanesa; López-Gonzálvez, Ángeles; Barbas, Coral
2015-12-01
The origin of missing values can be caused by different reasons and depending on these origins missing values should be considered differently and dealt with in different ways. In this research, four methods of imputation have been compared with respect to revealing their effects on the normality and variance of data, on statistical significance and on the approximation of a suitable threshold to accept missing data as truly missing. Additionally, the effects of different strategies for controlling familywise error rate or false discovery and how they work with the different strategies for missing value imputation have been evaluated. Missing values were found to affect normality and variance of data and k-means nearest neighbour imputation was the best method tested for restoring this. Bonferroni correction was the best method for maximizing true positives and minimizing false positives and it was observed that as low as 40% missing data could be truly missing. The range between 40 and 70% missing values was defined as a "gray area" and therefore a strategy has been proposed that provides a balance between the optimal imputation strategy that was k-means nearest neighbor and the best approximation of positioning real zeros. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Xie, Zuo-ping; Zhao, Bo-wen; Yuan, Hua; Hua, Qi-qi; Jin, She-hong; Shen, Xiao-yan; Han, Xin-hong; Zhou, Jia-mei; Fang, Min; Chen, Jin-hong
2013-01-01
Background: To establish the reference range of the angle between ascending aorta and main pulmonary artery of fetus in the second and third trimester using spatiotemporal image correlation (STIC), and to investigate the value of this angle in prenatal screening of conotruncal defects (CTDs). Materials and Methods: Volume images of 311 normal fetuses along with 20 fetuses with congenital heart diseases were recruited in this cross-sectional study. An offline analysis of acquired volume datasets was carried out with multiplanar mode. The angle between aorta and pulmonary artery was measured by navigating the pivot point and rotating axes and the reference range was established. The images of ascending aorta and main pulmonary artery in fetuses with congenital heart diseases were observed by rotating the axes within the normal angle reference range. Results: The angle between ascending aorta and main pulmonary artery of the normal fetus (range: 59.1˚~97.0˚, mean ± SD: 78.0˚ ± 9.7˚) was negatively correlated with gestational age (r = -0.52; p<0.01). By rotating the normal angle range corresponding to gestational age, the fetuses with CTD could not display views of their left ventricular long axis and main pulmonary trunk correctly. Conclusion: The left ventricular long axis and main pulmonary trunk views can be displayed using STIC so that the echocardiographic protocol of the cardiovascular joint could be standardized. The reference range of the angle between ascending aorta and main pulmonary artery is clinically useful in prenatal screening of CTD and provides a reliable quantitative standard to estimate the spatial relationship of the large arteries of fetus. PMID:24520485
Nonlinear dynamics in ecosystem response to climatic change: case studies and policy implications.
Virginia R. Burkett; Douglas A. Wilcox; Robert Stottlemeyer; Wylie Barrow; Dan Fagre; Jill Baron; Jeff Price; Jennifer L. Nielsen; Craig D. Allen; David L. Peterson; Greg Ruggerone; Thomas Doyle
2005-01-01
Many biological, hydrological, and geological processes are interactively linked in ecosystems. These ecological phenomena normally vary within bounded ranges, but rapid, nonlinear changes to markedly different conditions can be triggered by even small differences if threshold values are exceeded. Intrinsic and extrinsic ecological thresholds can lead to effects that...
Sivgin, Serdar; Karamustafaoglu, Mehmet Fatih; Yildizhan, Esra; Zararsiz, Gokmen; Kaynar, Leylagul; Eser, Bulent; Cetin, Mustafa; Unal, Ali
2016-08-01
Hematopoietic stem cell transplantation is a common and preferred treatment of lymphomas in many centers. Our goal was to determine the association between pretransplant iron overload and survival in patients who underwent autologous hematopoietic stem cell transplantation (autoHSCT). A total of 165 patients with lymphoma, who underwent autoHSCT between the years of 2007 and 2014, were included in this study. Ferritin levels were used to determine iron status; the cut-off value was 500 ng/mL. The relationship between iron overload and survival was assessed by statistical analysis. The median ferritin level in the normal ferritin (ferritin < 500) group was 118 ng/mL (range, 9-494 ng/mL) and in the high-ferritin group (ferritin ≥ 500), it was 908 ng/mL (range, 503-4549 ng/mL). A total of 64 (38.8%) patients died during follow-up. Of these patients that died, 52 (81.25%) were in the high-ferritin group, and 12 (18.75%) were in the normal ferritin group (P ≤ .001). Twelve (14.1%) of 85 patients died in the normal ferritin group, and 52 (65.0%) of 80 patients died in the high-ferritin group. The overall mortality was significantly higher in the high-ferritin group (P < .001). The median overall survival was 42 months (range, 25-56 months) in the normal-ferritin group and20 months (range, 5-46) in the high-ferritin group. The difference between the groups was statistically significant (P < .001). The median disease-free survival was 39 months (range, 16-56) in the normal ferritin group and 10 months (range, 3-29) in the high-ferritin group. The difference between the groups was statistically significant (P < .001). Elevated serum ferritin levels might predict poorer survival in autoHSCT recipients. Copyright © 2016 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Farid, N.R.; Kennedy, C.
We assessed the efficacy of a new thyroxine radioimmunoassay kit (Abbott) in which polyethylene glycol is used to separate bound from free hormone. Mean serum thyroxine was 88 +- 15 (+-SD) ..mu..g/liter for 96 normal persons. Results for hypothyroid and hyperthyroid persons were clearly separated from those for normal individuals. Women taking oral contraceptive preparations showed variable increases in their serum thyroxine values. The coefficient of variation ranged from 1 to 3% within assay and from 5.4 to 11% among different assays. Excellent parallelism was demonstrated between thyroxine values estimated by this method and those obtained either by competitive proteinmore » binding or by a separate radioimmunoassay for the hormone.« less
Ku-band radar threshold analysis
NASA Technical Reports Server (NTRS)
Weber, C. L.; Polydoros, A.
1979-01-01
The statistics of the CFAR threshold for the Ku-band radar was determined. Exact analytical results were developed for both the mean and standard deviations in the designated search mode. The mean value is compared to the results of a previously reported simulation. The analytical results are more optimistic than the simulation results, for which no explanation is offered. The normalized standard deviation is shown to be very sensitive to signal-to-noise ratio and very insensitive to the noise correlation present in the range gates of the designated search mode. The substantial variation in the CFAR threshold is dominant at large values of SNR where the normalized standard deviation is greater than 0.3. Whether or not this significantly affects the resulting probability of detection is a matter which deserves additional attention.
[Peculiarities of cerebral structures functioning in adolescents with achondroplasia].
Skripnikov, A A; Dolganova, T I; Aranovich, A M
2013-01-01
Complex neurophysiological examination (rheoencephalography, electroencephalography) was carried out in 12 adolescents 12 to 18 years old in order to reveal the peculiarities of cerebral structures functioning in adolescents with achondroplasia. Some deviations from the normal values were found out: reduced blood filling of the brain vessels in the pools of a. carotis interna and a. vertebralis, rheoencephalographic signs of intracranial hypertension of mild degree and brain cycling characterized by moderate and significant amplitude increase, presence of pathological types (delta-, theta-) of the rhythmics and the reduction of the physiological ones (alpha-, beta-). At the same time the peculiarities of rheoencephalographic indices were observed while functional testings (hypercapnia, hyperoxia). Brain cycling differed from normal values by weaker response to the weight-bearing, mainly in alpha- and beta-ranges.
Kenney, Kimbra; Landau, Mark E; Gonzalez, Rodney S; Hundertmark, Julie; O'Brien, Karen; Campbell, William W
2012-03-01
In this investigation we assessed the spectrum of creatine kinase (CK) responses in military recruits undergoing basic training. Musculoskeletal examination data, questionnaire findings, and CK levels were obtained from 499 recruits at days 0, 3, 7, and 14 of training. Correlations of CK with ethnicity, age, body mass index, exercise, muscle pain, and climate were obtained. None of the subjects developed clinical exertional rhabdomyolysis (ER). The mean/median serum CK values were 223/157, 734/478, 1226/567, and 667/486 IU/L at days 0, 3, 7, and 14, respectively, with a wide overall range (34-35,056 IU/L). African-American subjects had higher mean CK levels. CK elevations and muscle pain are common during basic training. Widely accepted laboratory diagnostic values for ER are routinely exceeded in this military recruits, suggesting that CK levels >50 times the upper limit of normal are more specific. The findings support using CK as a marker for ER. Normal laboratory reference ranges for CK should be published by ethnicity. Copyright © 2011 Wiley Periodicals, Inc.
Fault detection of helicopter gearboxes using the multi-valued influence matrix method
NASA Technical Reports Server (NTRS)
Chin, Hsinyung; Danai, Kourosh; Lewicki, David G.
1993-01-01
In this paper we investigate the effectiveness of a pattern classifying fault detection system that is designed to cope with the variability of fault signatures inherent in helicopter gearboxes. For detection, the measurements are monitored on-line and flagged upon the detection of abnormalities, so that they can be attributed to a faulty or normal case. As such, the detection system is composed of two components, a quantization matrix to flag the measurements, and a multi-valued influence matrix (MVIM) that represents the behavior of measurements during normal operation and at fault instances. Both the quantization matrix and influence matrix are tuned during a training session so as to minimize the error in detection. To demonstrate the effectiveness of this detection system, it was applied to vibration measurements collected from a helicopter gearbox during normal operation and at various fault instances. The results indicate that the MVIM method provides excellent results when the full range of faults effects on the measurements are included in the training set.
A neuroendocrine predisposition for homosexuality in men.
Dörner, G; Rohde, W; Stahl, F; Krell, L; Masius, W G
1975-01-01
In male rats, androgen deficiency during a critical hypothalamic organizational period was shown to give rise to a predominantly female-differentiated brain, homosexual behavior, and demonstration of a positive estrogen feedback effect. A positive estrogen feedback effect was also induced in intact homosexual men in contrast to intact heterosexual and bisexual men. Thus in 21 homosexual men an intravenous injection of 20 mg Presomen (Premarin) produced a significant decrease of serum LH levels followed by an increase above initial LH values. In 20 heterosexual and in five bisexual men, by contrast, intravenous estrogen administration, while producing a significant decrease of the serum LH level, was not followed by an increase above the initial LH values. Using a radioimmunoassay, plasma testosterone levels and 24-hr urinary excretions of unconjugated testosterone of adult homosexual men were found to be in the normal range as observed in heterosexual men. This finding suggests that homosexual men possess a predominantly female-differentiated brain which may be activated to homosexual behavior by normal or approximately normal androgen levels in adulthood.
Serum enzymes levels and influencing factors in three indigenous Ethiopian goat breeds.
Tibbo, M; Jibril, Y; Woldemeskel, M; Dawo, F; Aragaw, K; Rege, J E O
2008-12-01
Serum enzymes were studied in 163 apparently healthy goats from three indigenous goat breeds of Ethiopia. The effect of breed, age, sex and season on alanine aminotransferase (ALT) / glutamic pyruvic transaminase (GPT), aspartate aminotransferase (AST) / glutamic oxalacetic transaminases (GOT), alkaline phosphatase (ALP) and acid phosphatase (AcP) levels was assessed. The mean serum enzymes levels of the indigenous Arsi-Bale, Central Highland and Long-eared Somali goat breeds ranged from 14.0-20.2 iu L(-1) for ALT/GPT, from 43.2-49.3 iu L(-1) for AST/GOT, from 83.7-98.8 iu L(-1) for ALP, and from 2.99-4.23 iu L(-1) for AcP, were within the normal range for goats elsewhere. Breed had significant influence on AST/GOT values. Sex had significant effect on ALT/GPT for Arsi-Bale goats with higher values in males than females. Age was significant on all serum enzymes studied in the Arsi-Bale goats and on ALP in the Central Highland goats. Season had significant influence on all serum enzymes except for ALT/GPT in the Arsi-Bale goats. The serum enzyme levels of these indigenous goat breeds can be used as normal reference values for Ethiopian goat breeds adapted to similar agro-ecology and production system.
Cardiopulmonary fitness and muscle strength in patients with osteogenesis imperfecta type I.
Takken, Tim; Terlingen, Heike C; Helders, Paul J M; Pruijs, Hans; Van der Ent, Cornelis K; Engelbert, Raoul H H
2004-12-01
To evaluate cardiopulmonary function, muscle strength, and cardiopulmonary fitness (VO 2 peak) in patients with osteogenesis imperfecta (OI). In 17 patients with OI type I (mean age 13.3 +/- 3.9 years) cardiopulmonary function was assessed at rest using spirometry, plethysmography, electrocardiography, and echocardiography. Exercise capacity was measured using a maximal exercise test on a bicycle ergometer and an expired gas analysis system. Muscle strength in shoulder abductors, hip flexors, ankle dorsal flexor, and grip strength were measured. All results were compared with reference values. Cardiopulmonary function at rest was within normal ranges, but when it was compared with normal height for age and sex, vital capacities were reduced. Mean absolute and relative VO 2 peak were respectively -1.17 (+/- 0.67) and -1.41 (+/- 1.52) standard deviations lower compared with reference values ( P < .01). Muscle strength also was significantly reduced in patients with OI, ranging from -1.24 +/- 1.40 to -2.88 +/- 2.67 standard deviations lower compared with reference values. In patients with OI type I, no pulmonary or cardiac abnormalities at rest were found. The exercise tolerance and muscle strength were significantly reduced in patients with OI, which might account for their increased levels of fatigue during activities of daily living.
Infrared radiation of thin plastic films.
NASA Technical Reports Server (NTRS)
Tien, C. L.; Chan, C. K.; Cunnington, G. R.
1972-01-01
A combined analytical and experimental study is presented for infrared radiation characteristics of thin plastic films with and without a metal substrate. On the basis of the thin-film analysis, a simple analytical technique is developed for determining band-averaged optical constants of thin plastic films from spectral normal transmittance data for two different film thicknesses. Specifically, the band-averaged optical constants of polyethylene terephthalate and polyimide were obtained from transmittance measurements of films with thicknesses in the range of 0.25 to 3 mil. The spectral normal reflectance and total normal emittance of the film side of singly aluminized films are calculated by use of optical constants; the results compare favorably with measured values.
Ultrasonic attenuation in superconducting molybdenum-rhenium alloys.
NASA Technical Reports Server (NTRS)
Ashkin, M.; Deis, D. W.; Gottlieb, M.; Jones, C. K.
1971-01-01
Investigation of longitudinal sound attenuation in superconducting Mo-Re alloys as a function of temperature, magnetic field, and frequency. Evaporated thin film CdS transducers were used for the measurements at frequencies up to 3 GHz. The normal state attenuation coefficient was found to be proportional to the square of frequency over this frequency range. Measurements in zero magnetic field yielded a value of the energy gap parameter close to the threshold value of 3.56 kTc, appropriate to a weakly coupled dirty limit superconductor.
NASA Astrophysics Data System (ADS)
Stünitz, Holger; Keulen, Nynke; Hirose, Takehiro; Heilbronner, Renée
2010-01-01
Microstructures and grain size distribution from high velocity friction experiments are compared with those of slow deformation experiments of Keulen et al. (2007, 2008) for the same material (Verzasca granitoid). The mechanical behavior of granitoid gouge in fast velocity friction experiments at slip rates of 0.65 and 1.28 m/s and normal stresses of 0.4-0.9 MPa is characterized by slip weakening in a typical exponential friction coefficient vs displacement relationship. The grain size distributions yield similar D-values (slope of frequency versus grain size curve = 2.2-2.3) as those of slow deformation experiments (D = 2.0-2.3) for grain sizes larger than 1 μm. These values are independent of the total displacement above a shear strain of about γ = 20. The D-values are also independent of the displacement rates in the range of ˜1 μm/s to ˜1.3 m/s and do not vary in the normal stress range between 0.5 MPa and 500 MPa. With increasing displacement, grain shapes evolve towards more rounded and less serrated grains. While the grain size distribution remains constant, the progressive grain shape evolution suggests that grain comminution takes place by attrition at clast boundaries. Attrition produces a range of very small grain sizes by crushing with a D <-value = 1. The results of the study demonstrate that most cataclastic and gouge fault zones may have resulted from seismic deformation but the distinction of seismic and aseismic deformation cannot be made on the basis of grain size distribution.
Bravo, Paco E; Chien, David; Javadi, Mehrbod; Merrill, Jennifer; Bengel, Frank M
2010-06-01
Electrocardiographic gating is increasingly used for (82)Rb cardiac PET/CT, but reference ranges for global functional parameters are not well defined. We sought to establish reference values for left ventricular ejection fraction (LVEF), end systolic volume (ESV), and end diastolic volume (EDV) using 4 different commercial software packages. Additionally, we compared 2 different approaches for the definition of a healthy individual. Sixty-two subjects (mean age +/- SD, 49 +/- 9 y; 85% women; mean body mass index +/- SD, 34 +/- 10 kg/m(2)) who underwent (82)Rb-gated myocardial perfusion PET/CT were evaluated. All subjects had normal myocardial perfusion and no history of coronary artery disease (CAD) or cardiomyopathy. Subgroup 1 consisted of 34 individuals with low pretest probability of CAD (<10%), and subgroup 2 comprised 28 subjects who had no atherosclerosis on a coronary CT angiogram obtained concurrently during the PET/CT session. LVEF, ESV, and EDV were calculated at rest and during dipyridamole-induced stress, using CardIQ Physio (a dedicated PET software) and the 3 major SPECT software packages (Emory Cardiac Toolbox, Quantitative Gated SPECT, and 4DM-SPECT). Mean LVEF was significantly different among all 4 software packages. LVEF was most comparable between CardIQ Physio (62% +/- 6% and 54% +/- 7% at stress and rest, respectively) and 4DM-SPECT (64% +/- 7% and 56% +/- 8%, respectively), whereas Emory Cardiac Toolbox yielded higher values (71% +/- 6% and 65% +/- 6%, respectively, P < 0.001) and Quantitated Gated SPECT lower values (56% +/- 8% and 50% +/- 8%, respectively, P < 0.001). Subgroup 1 (low likelihood) demonstrated higher LVEF values than did subgroup 2 (normal CT angiography findings), using all software packages (P < 0.05). However, mean ESV and EDV at stress and rest were comparable between both subgroups (p = NS). Intra- and interobserver agreement were excellent for all methods. The reference range of LVEF and LV volumes from gated (82)Rb PET/CT varies significantly among available software programs and therefore cannot be used interchangeably. LVEF results were higher when healthy subjects were defined by a low pretest probability of CAD than by normal CT angiography results.
Bayesian alternative to the ISO-GUM's use of the Welch Satterthwaite formula
NASA Astrophysics Data System (ADS)
Kacker, Raghu N.
2006-02-01
In certain disciplines, uncertainty is traditionally expressed as an interval about an estimate for the value of the measurand. Development of such uncertainty intervals with a stated coverage probability based on the International Organization for Standardization (ISO) Guide to the Expression of Uncertainty in Measurement (GUM) requires a description of the probability distribution for the value of the measurand. The ISO-GUM propagates the estimates and their associated standard uncertainties for various input quantities through a linear approximation of the measurement equation to determine an estimate and its associated standard uncertainty for the value of the measurand. This procedure does not yield a probability distribution for the value of the measurand. The ISO-GUM suggests that under certain conditions motivated by the central limit theorem the distribution for the value of the measurand may be approximated by a scaled-and-shifted t-distribution with effective degrees of freedom obtained from the Welch-Satterthwaite (W-S) formula. The approximate t-distribution may then be used to develop an uncertainty interval with a stated coverage probability for the value of the measurand. We propose an approximate normal distribution based on a Bayesian uncertainty as an alternative to the t-distribution based on the W-S formula. A benefit of the approximate normal distribution based on a Bayesian uncertainty is that it greatly simplifies the expression of uncertainty by eliminating altogether the need for calculating effective degrees of freedom from the W-S formula. In the special case where the measurand is the difference between two means, each evaluated from statistical analyses of independent normally distributed measurements with unknown and possibly unequal variances, the probability distribution for the value of the measurand is known to be a Behrens-Fisher distribution. We compare the performance of the approximate normal distribution based on a Bayesian uncertainty and the approximate t-distribution based on the W-S formula with respect to the Behrens-Fisher distribution. The approximate normal distribution is simpler and better in this case. A thorough investigation of the relative performance of the two approximate distributions would require comparison for a range of measurement equations by numerical methods.
The course of skull deformation from birth to 5 years of age: a prospective cohort study.
van Vlimmeren, Leo A; Engelbert, Raoul Hh; Pelsma, Maaike; Groenewoud, Hans Mm; Boere-Boonekamp, Magda M; der Sanden, Maria Wg Nijhuis-van
2017-01-01
In a continuation of a prospective longitudinal cohort study in a healthy population on the course of skull shape from birth to 24 months, at 5 years of age, 248 children participated in a follow-up assessment using plagiocephalometry (ODDI-oblique diameter difference index, CPI-cranio proportional index). Data from the original study sampled at birth, 7 weeks, 6, 12, and 24 months were used in two linear mixed models. (1) if deformational plagiocephaly (ODDI <104%) and/or positional preference at 7 weeks of age are absent, normal skull shape can be predicted at 5 years of age; (2) if positional preference occurs, ODDI is the highest at 7 weeks and decreases to a stable lowest value at 2 and 5 years of age; and (3) regarding brachycephaly, all children showed the highest CPI at 6 months of age with a gradual decrease over time. The course of skull deformation is favourable in most of the children in The Netherlands; at 5 years of age, brachycephaly is within the normal range for all children, whereas the severity of plagiocephaly is within the normal range in 80%, within the mild range in 19%, and within the moderate/severe range in 1%. Medical consumption may be reduced by providing early tailored counselling. What is Known: • Skull deformation prevalence increased after recommendations against Sudden Infant Death Syndrome, little is known about the longitudinal course. • Paediatric physical therapy intervention between 2 and 6 months of age reduces deformational plagiocephaly at 6 and 12 months of age. What is New: • The course of skull deformation is favourable in most of the children in The Netherlands; at 5 years of age, deformational brachycephaly is within the normal range for all children, whereas the severity of deformational plagiocephaly is within the normal range in 80%, within the mild range in 19%, and within the moderate to severe range in only 1%. • Paediatric physical therapy intervention does not influence the long-term outcome; it only influences the earlier decrease of the severity of deformational plagiocephaly.
Qin, Feng-Zhen; Li, Sheng-Li; Wen, Hua-Xuan; Ouyang, Yu-Rong; Zheng, Qiong; Bi, Jing-Ru
2014-06-01
To establish the normal reference ranges of transabdominal ultrasound measurements of the posterior fossa structure in fetuses at 11 to 13⁺⁶ gestational weeks and explore their clinical value in screening open spina bifida (OSB). Between January, 2013 and September, 541 randomly selected normal fetuses underwent nuchal translucency at the gestational age 11 to 13⁺⁶ weeks. The parameters of the posterior fossa were measured in mid-sagittal view of the fetal face and the axial view of the transverse cerebellum insonated through the anterior fontanel by transabdominal ultrasound to establish the normal reference ranges. The measurements were obtained from 3 fetuses with OSB for comparison with the reference ranges. In normal fetuses, the parameters of the posterior fossa measured in the two views showed no significant differences (P>0.05). Two high echogenic lines were observed in normal fetuses, as compared with one in fetuses with OSB representing the posterior border of the brain stem and the anterior border of the fourth ventricle. The line between the posterior border of the fourth ventricle and the anterior border of the cisterna magna was not displayed in fetuses with OSB. The anteroposterior diameters of the brain stem, the fourth ventricle, and cisterna magna all increased in positive correlation with the crown-lump length in normal fetuses. In the 3 OSB fetuses, the anteroposterior diameter of the brain stem exceeded the 95th percentile and the anteroposterior diameter of fourth ventrical-cisterner magena was below the 5th percentile of the reference range for CRL; the brain stem to fourth ventrical-cisterner magena anteroposterior diameter ratio was increased to above 1. The established normal reference ranges of the parameters of fetal posterior fossa may provide assistance in early OSB detection. The absence of the posterior border of the fourth ventricle and the anterior border of the cisterna magna and a brainstem to fourth ventrical-cisterner magena anteroposterior diameter ratio greater than 1 can be indicative of OSB at 11 to 13⁺⁶ gestational weeks.
Paglialonga, Alessia; Barozzi, Stefania; Brambilla, Daniele; Soi, Daniela; Cesarani, Antonio; Spreafico, Emanuela; Tognola, Gabriella
2014-11-01
To assess if young subjects affected by Williams syndrome (WS) with normal middle ear functionality and normal hearing thresholds might have subtle auditory dysfunctions that could be detected by using clinically available measurements. Otoscopy, acoustic reflexes, tympanometry, pure-tone audiometry, and distortion product otoacoustic emissions (DPOAEs) were measured in a group of 13 WS subjects and in 13 age-matched, typically developing control subjects. Participants were required to have normal otoscopy, A-type tympanogram, normal acoustic reflex thresholds, and pure-tone thresholds≤15 dB HL at 0.5, 1, and 2 kHz bilaterally. To limit the possible influence of middle ear status on DPOAE recordings, we analyzed only data from ears with pure-tone thresholds≤15 dB HL across all octave frequencies in the range 0.25-8 kHz, middle ear pressure (MEP)>-50 daPa, static compliance (SC) in the range 0.3-1.2 cm3, and ear canal volume (ECV) in the range 0.2-2 ml, and we performed analysis of covariance to remove the possible effects of middle ear variables on DPOAEs. No differences in mean hearing thresholds, SC, ECV, and gradient were observed between the two groups, whereas significantly lower MEP values were found in WS subjects as well as significantly decreased DPOAEs up to 3.2 kHz after adjusting for differences in middle ear status. Results revealed that WS subjects with normal hearing thresholds (≤15 dB HL) and normal middle ear functionality (MEP>-50 daPa, SC in the range 0.3-1.2 cm3, ECV in the range 0.2-2 ml) might have subtle auditory dysfunctions that can be detected by using clinically available methods. Overall, this study points out the importance of using otoacoustic emissions as a complement to routine audiological examinations in individuals with WS to detect, before the onset of hearing loss, possible subtle auditory dysfunctions so that patients can be early identified, better monitored, and promptly treated. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
González-Méijome, José M; López-Alemany, Antonio; Lira, Madalena; Almeida, José B; Oliveira, M Elisabete C D Real; Parafita, Manuel A
2007-01-01
The purpose of the present study was to develop mathematical relationships that allow obtaining equilibrium water content and refractive index of conventional and silicone hydrogel soft contact lenses from refractive index measures obtained with automated refractometry or equilibrium water content measures derived from manual refractometry, respectively. Twelve HEMA-based hydrogels of different hydration and four siloxane-based polymers were assayed. A manual refractometer and a digital refractometer were used. Polynomial models obtained from the sucrose curves of equilibrium water content against refractive index and vice-versa were used either considering the whole range of sucrose concentrations (16-100% equilibrium water content) or a range confined to the equilibrium water content of current soft contact lenses (approximately 20-80% equilibrium water content). Values of equilibrium water content measured with the Atago N-2E and those derived from the refractive index measurement with CLR 12-70 by the applications of sucrose-based models displayed a strong linear correlation (r2 = 0.978). The same correlations were obtained when the models are applied to obtain refractive index values from the Atago N-2E and compared with those (values) given by the CLR 12-70 (r2 = 0.978). No significantly different results are obtained between models derived from the whole range of the sucrose solution or the model limited to the normal range of soft contact lens hydration. Present results will have implications for future experimental and clinical research regarding normal hydration and dehydration experiments with hydrogel polymers, and particularly in the field of contact lenses. 2006 Wiley Periodicals, Inc.
Aftab, Ghazal; Rajaei, Seyed Mehdi; Faghihi, Houman
2017-09-01
Objectives The objective of this study was to compare the Schirmer tear test I values obtained from placement of Schirmer tear test (STT) strips in ventral and dorsal conjunctival fornices and to investigate any correlation between age, body weight and STT values in clinically normal cats. Methods Twenty-eight intact adult domestic shorthair and Persian were used in this study. The cats were gently physically restrained in a sternal position, and a Schirmer tear strip was placed on each eye in the ventral conjunctival fornix at one-third of the distance from the temporal to nasal canthus for 60 s. Then, the wetted portion of the strips was measured as mm/min (L-STT I). After 48 h, the same procedure was performed on each eye in the dorsal conjunctival fornix (U-STT I). Results Mean ± SD STT values of the ventral and dorsal conjunctival fornices were 20.80 ± 2.25 mm/min (range 14-25 mm/min; 95% confidence interval [CI] 19.92-21.67) and 18.28 ± 2.27 mm/min (range 15-22 mm/min; 95% CI 17.39-19.16) in all of the study population, respectively. A significant difference was found between STT values obtained from the ventral and dorsal conjunctival fornices ( P <0.001). There was no correlation between the age and body weight of the animals and STT I values. Conclusions and relevance This study compared the STT I values of the dorsal and ventral conjunctival fornices in cats. The difference was significant between the L-STT I and U-STT I values; however, the L-STT I and U-STT I values were within normal reference intervals. The U-STT I data have diagnostic value that might be of benefit in cases where there is a problem in the ventral conjunctival fornix.
Lourenço, Ruy V.
1969-01-01
Diaphragm activity during carbon dioxide breathing and total chest compliance during diaphragm relaxation were measured in eight obese subjects: four with normal blood gases and four with hypercapnia and hypoxemia. Whereas there were no significant differences in the values of total chest compliance between the two groups, there were marked differences in diaphragm activity. The increase in integrated electrical activity in the diaphragm, per millimeter increment in carbon dioxide tension in the arterial blood, averaged 66 units (range: 48-90) in the obese-normal subjects and 17 units (range: 12-22) in the obese-hypoventilation subjects. These results suggest that an incapacity to increase the activity in the respiratory muscles, to levels necessary to overcome the load caused by obesity, plays a major role in the genesis of respiratory failure in obese subjects. PMID:5822573
Ultrasound assisted immersion freezing of broccoli (Brassica oleracea L. var. botrytis L.).
Xin, Ying; Zhang, Min; Adhikari, Benu
2014-09-01
The aim of this study was to research the ultrasound-assisted freezing (UAF) of broccoli. CaCl2 solution was used as freezing medium. The comparative advantage of using UAF over normal freezing on the freezing time, cell-wall bound calcium to total calcium ratio, textural properties, color, drip loss and L-ascorbic acid contents was evaluated. The application of UAF at selected acoustic intensity with a range of 0.250-0.412 W/cm(2) decreased the freezing time and the loss of cell-wall bound calcium content. Compared to normal freezing, the values of textural properties, color, L-ascorbic acid content were better preserved and the drip loss was significantly minimized by the application of UAF. However, when outside that range of acoustic intensity, the quality of the ultrasound-assisted frozen broccoli was inferior compared to that of the normally frozen samples. Selected the appropriate acoustic intensity was very important for the application of UAF. Copyright © 2014 Elsevier B.V. All rights reserved.
Griffin, Brooke L; Burkiewicz, Jill S; Peppers, Laura R; Warholak, Terri L
2009-07-01
The clinical effectiveness of a group-visit model versus individual point-of-care visits is compared by International Normalized Ratio (INR) monitoring in a pharmacist-managed anticoagulation clinic. This study was a prospective, randomized, repeated-measures, two-group, intention-to-treat comparison and survey at a pharmacist-managed anticoagulation clinic in a managed-care ambulatory care setting. Patients were eligible for this study if they were taking warfarin therapy for at least 30 days, had a goal INR range, and provided consent. At a routine point-of-care visit, eligible patients were randomly invited to participate in group visits. The number of visits and INR values were documented prospectively for both groups during the 16-week study period. Of the 45 patients who consented and enrolled in group visits, 28 patients participated for the 16-week study period. The control group included 108 patients seen by a pharmacist for individual anticoagulation appointments. No significant difference in the percentage of INR values within the therapeutic range was detected between patients in the group-visit model versus patients receiving individual visits (59% versus 56.6%, respectively; p = 0.536). Seventy-three percent of INR values for patients who attended group visits were within +/- 0.2 of the desired INR range compared with 71.9% of those in the control group ( p = 0.994). In addition, 79% of group-visit patients were within the therapeutic range at their last clinic visit compared with 67% of patients who attended individual appointments (p = 0.225). Group visits were preferred by 51% (n = 38) of patients who completed the satisfaction survey. Of the 92 patients who declined group-visit participation, 36% indicated that the time of day that group visits were offered was inconvenient. There were no thromboembolic or hemorrhagic events documented in either group during the study period. Group visits in a pharmacist-managed anticoagulation clinic may provide a safe and effective alternative to individual appointments.
A short note on the maximal point-biserial correlation under non-normality.
Cheng, Ying; Liu, Haiyan
2016-11-01
The aim of this paper is to derive the maximal point-biserial correlation under non-normality. Several widely used non-normal distributions are considered, namely the uniform distribution, t-distribution, exponential distribution, and a mixture of two normal distributions. Results show that the maximal point-biserial correlation, depending on the non-normal continuous variable underlying the binary manifest variable, may not be a function of p (the probability that the dichotomous variable takes the value 1), can be symmetric or non-symmetric around p = .5, and may still lie in the range from -1.0 to 1.0. Therefore researchers should exercise caution when they interpret their sample point-biserial correlation coefficients based on popular beliefs that the maximal point-biserial correlation is always smaller than 1, and that the size of the correlation is always further restricted as p deviates from .5. © 2016 The British Psychological Society.
Haematological studies on vegans.
Sanders, T A; Ellis, F R; Dickerson, J W
1978-07-01
1. The concentrations of vitamin B12 and folate in the serum and folate in the erythrocytes were determined and full blood counts made on a series of caucasian vegans and omnivore controls. 2. The blood counts and films were normal in all the vegans and no subject had a haemoblobin concentration below the lower limit of normality. 3. Although within the normal range, male but not female vegans had lower values for erythrocyte counts and higher values for mean corpuscular volume and mean corpuscular haemoglobin than their controls regardless of whether they were taking vitamin B12 supplements or not. 4. The mean serum vitamin B12 concentration was lower in the vegans not taking vitamin B12 supplements and in those using foods supplemented with the vitamin than in the controls, but in no subject was it below 80 ng/1. 5. The serum folate concentrations were higher in the vegans than in their controls. The mean value for erythrocyte folate tended to be greater in the vegans not taking vitamin B12 supplements. No subject had an erythrocyte folate concentration of less than 100 microgram/1. 6. It is concluded that megaloblastic anaemia is very rare in caucasian vegans and that a diet consisting entirely of plant foods is generally adequate to promote normal blood formation providing it is composed of a mixture of unrefined cereals, pulses, nuts, fruit and vegetables and is supplemented with vitamin B12.
Thapa, N B; Shah, S; Pradhan, A; Rijal, K; Pradhan, A; Basnet, S
2015-01-01
Background Ultrasonography is one of the most common imaging modality to measure dimensions of visceral organs in children. However, the normal limit of size of visceral organs according to age and body habitus has not been specified in the standard textbooks. This might result in under detection of organomegaly in pediatrics population. Objective The objective of this study was to determine the normal range of dimensions for the liver, spleen, and kidney in healthy children. Method This is prospective cross-sectional, hospital-based study done at Tertiary-care teaching hospital. Participants included 272 pediatric subjects (152 male and 120 female) with normal physical or sonographic findings who were examined because of problems unrelated to the measured organs. The subjects were one month to 15 year (180 months) old. All measured organs were sonographically normal. Relationships of the dimensions of these organs with sex, age, body weight and height were investigated. Limits of normal dimensions of these organs were defined. Result Normal length of liver, kidneys and spleen were obtained sonographically for 272 children (152 male [55.9%] and 120 female [44.1%]) in the age group from 1 months to 15 (180 months) years. The mean age was 45.78 months (SD, 44.73). The measured dimensions of all these organs showed highest correlation with height and age so the descriptive analysis of the organ dimensions (mean, minimum, and maximum values, SD and 5th and 95th percentiles) were expressed in 10 age groups along with height range of the included children. The mean length of right kidney was shorter than the left kidney length, and the difference was statistically significant (p = 0.001). Conclusion This study provides practical and comprehensive guide to the normal visceral organ dimension in pediatric population. The normal range limit of the liver, spleen, and kidney determined in this study could be used as a reference in daily practice in local radiology clinics.
Kopjar, Nevenka; Kasuba, Vilena; Milić, Mirta; Rozgaj, Ruzica; Zeljezić, Davor; Gajski, Goran; Mladinić, Marin; Garaj-Vrhovac, Vera
2010-06-01
The cytokinesis-block micronucleus (CBMN) assay on peripheral blood lymphocytes is one of the most important methods employed in cytogenetic biomonitoring. For the purposes of biological dosimetry, it is important to know the spontaneous frequency of a biomarker and its normal values in general population. These values are used for population databases, which should be updated regularly. In this study, MN levels were investigated in cytokinesis-blocked lymphocytes of 200 healthy male and female blood donors selected at random from the general population of Croatia. The aim was to assess the variability and determine possible influences of external and/or internal factors on the background levels of MN and to establish the cut-off value for the CBMN assay. The background frequency of MN was (6.90+/-3.32) MN (median 7 MN) and the range was 0 to 18 MN per 1000 binuclear lymphocytes. The cut-off value, which corresponds to 95th percentile of the distribution of 200 individual values, was 12.5 MN. Spontaneous formation of MN was influenced by sex, age, and smoking. Women had higher MN levels than men. However, only age and smoking significantly increased the values of all parameters evaluated by the CBMN assay. Since the existing literature data on smoking-related formation of MN are contradictory, we will continue these investigations to resolve how the number of cigarettes smoked per day and the duration of smoking in years influence the results of the CBMN assay. Our results are consistent with the background MN frequencies reported by other cytogenetic laboratories worldwide. Normal and cut-off values estimated in this study will be used to update the current general population data and as reference for occupationally or accidental exposure.
2010-01-01
Background Left atrial (LA) size is related to cardiovascular morbidity and mortality. Cardiovascular magnetic resonance (CMR) provides high quality images of the left atrium with high temporal resolution steady state free precession (SSFP) cine sequences. We used SSFP cines to define normal ranges for LA volumes and dimensions relative to gender, age and body surface area (BSA), and examine the relative value of 2D atrial imaging techniques in patients. For definition of normal ranges of LA volume we studied 120 healthy subjects after careful exclusion of cardiovascular abnormality (60 men, 60 women; 20 subjects per age decile from 20 to 80 years). Data were generated from 3-dimensional modeling, including tracking of the atrioventricular ring motion and time-volume curves analysis. For definition of the best 2D images-derived predictors of LA enlargement, we studied 120 patients (60 men, 60 women; age range 20 to 80 years) with a clinical indication for CMR. Results In the healthy subjects, age was associated with LA 4-chamber transverse and 3-chamber anteroposterior diameters, but not with LA volume. Gender was an independent predictor of most absolute LA dimensions and volume, but following normalization to BSA, some associations became non-significant. CMR normal ranges were modeled and are tabled for clinical use with normalization, where appropriate, for BSA and gender and display of parameter variation with age. The best 2D predictors of LA volume were the 2-chamber area and 3-chamber area (both r = 0.90, p < 0.001). Conclusions These CMR data show that LA dimensions and volume in healthy, individuals vary significantly by BSA, with lesser effects of age and gender. PMID:21070636
Quarterly environmental data summary for first quarter 1998
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1998-05-01
In support of the Weldon Spring Site Remedial Action Project Federal Facilities Agreement, a copy of the Quarterly Environmental Data Summary (QEDS) for the first quarter of 1998 is enclosed. The data presented in this letter and attachment constitute the QEDS. The data were received from the contract laboratories, verified by the Weldon Spring Site verification group and, except for air monitoring data and site KPA generated data (uranium analyses), merged into the data base during the first quarter of 1998. Air monitoring data presented are the most recent complete sets of quarterly data. Air data are not stored inmore » the data base, and KPA data are not merged into the regular data base. Significant data, defined as data values that have exceeded defined {open_quotes}above normal{close_quotes} Level 2 values, are discussed in this letter for Environmental Monitoring Plan (EMP) generated data only. Above normal Level 2 values are based, in ES&H procedures, on historical high values, DOE Derived Concentration Guides (DCGs), NPDES limits and other guidelines. The procedures also establish actions to be taken in the event that {open_quotes}above normal{close_quotes} data occur. All data received and verified during the first quarter were within a permissible range of variability except for those detailed below. Above normal occurrences are cited for groundwater, air, and NPDES data. There were none for springs or surface water. The following discussion offers a brief summary of the data merged during the first quarter that exceeded the above normal criteria and updates on past reported above normal data. The attached tables present the most recent data for air and the data merged into the data base during the first quarter 1998 for groundwater, NPDES, surface water, and springs. Graphs showing concentrations of selected contaminants of concern at some of the critical locations have also been included in this QEDS. The graphs are discussed in the separate sections.« less
Warren, McWilson; Spencer, Harrison C.; Churchill, Frederick C.; Francois, Velly Jean; Hippolyte, Robert; Staiger, Michael A.
1985-01-01
Measurement of blood cholinesterase activity and of the urinary metabolites of fenitrothion (p-nitrocresol) and malathion (monocarboxylic acid) was used to assess the exposure to these insecticides of workers in the Haitian malaria control programme and of residents in the sprayed houses. Cholinesterase activity was significantly reduced at the end of the working week in 3 out of 28 fenitrothion workers. Urinary levels of p-nitrocresol (PNC) in the spraymen ranged from 2.2 to 25.2 mg/l. In fenitrothion workers who had no direct contact with spraying (weighers and supervisors), the cholinesterase activity remained ≥ 75% of the normal control value, and the urinary PNC levels were relatively low. Urinary malathion monocarboxylic acid (MCA) levels at the end of the working week ranged between 1.1 and 5.3 mg/l in workers using malathion and their blood cholinesterase activity remained essentially normal. In both groups of workers the cholinesterase levels improved and the urinary excretion of metabolites decreased after 2 days of rest from the spraying operations. In the residents of the sprayed houses, low concentrations of PNC and MCA were detected in the urine 1 day after spraying and measurable but reduced levels were still present after 7 days. In all these cases the cholinesterase activity remained ≥ 75% of the normal control value. PMID:3874716
Evaluation and management of bradycardia in neonates and children.
Baruteau, Alban-Elouen; Perry, James C; Sanatani, Shubhayan; Horie, Minoru; Dubin, Anne M
2016-02-01
Heart rate is commonly used in pediatric early warning scores. Age-related changes in the anatomy and physiology of infants and children produce normal ranges for electrocardiogram features that differ from adults and vary with age. Bradycardia is defined as a heart rate below the lowest normal value for age. Pediatric bradycardia most commonly manifests as sinus bradycardia, junctional bradycardia, or atrioventricular block. As a result of several different etiologies, it may occur in an entirely structurally normal heart or in association with concomitant congenital heart disease. Genetic variants in multiple genes have been described to date in the pathogenesis of inherited sinus node dysfunction or progressive cardiac conduction disorders. Management and eventual prognosis of bradycardia in the young are entirely dependent upon the underlying cause. Reasons to intervene for bradycardia are the association of related symptoms and/or the downstream risk of heart failure or pause-dependent tachyarrhythmia. The simplest aspect of severe bradycardia management is reflected in the Pediatric and Advanced Life Support (PALS) guidelines. Early diagnosis and appropriate management are critical in many cases in order to prevent sudden death, and this review critically assesses our current practice for evaluation and management of bradycardia in neonates and children. Bradycardia is defined as a heart rate below the lowest normal value for age. Age related changes in the anatomy and physiology of infants and children produce normal ranges for electrocardiogram features that differ from adults and vary with age. Pediatric bradycardia most commonly manifests as sinus bradycardia, junctional bradycardia, or atrioventricular block. Management and eventual prognosis of bradycardia in the young are entirely dependent upon the underlying cause. Bradycardia may occur in a structurally normal heart or in association with congenital heart disease. Genetic variants in multiple genes have been described. Reasons to intervene for bradycardia are the association of related symptoms and/or the downstream risk of heart failure or pause-dependent tachyarrhythmia. Early diagnosis and appropriate management are critical in order to prevent sudden death.
[Using neural networks based template matching method to obtain redshifts of normal galaxies].
Xu, Xin; Luo, A-li; Wu, Fu-chao; Zhao, Yong-heng
2005-06-01
Galaxies can be divided into two classes: normal galaxy (NG) and active galaxy (AG). In order to determine NG redshifts, an automatic effective method is proposed in this paper, which consists of the following three main steps: (1) From the template of normal galaxy, the two sets of samples are simulated, one with the redshift of 0.0-0.3, the other of 0.3-0.5, then the PCA is used to extract the main components, and train samples are projected to the main component subspace to obtain characteristic spectra. (2) The characteristic spectra are used to train a Probabilistic Neural Network to obtain a Bayes classifier. (3) An unknown real NG spectrum is first inputted to this Bayes classifier to determine the possible range of redshift, then the template matching is invoked to locate the redshift value within the estimated range. Compared with the traditional template matching technique with an unconstrained range, our proposed method not only halves the computational load, but also increases the estimation accuracy. As a result, the proposed method is particularly useful for automatic spectrum processing produced from a large-scale sky survey project.
Human perceptions of colour rendition vary with average fidelity, average gamut, and gamut shape
DOE Office of Scientific and Technical Information (OSTI.GOV)
Royer, MP; Wilkerson, A.; Wei, M.
An experiment was conducted to evaluate how subjective impressions of color quality vary with changes in average fidelity, average gamut, and gamut shape (which considers the specific hues that are saturated or desaturated). Twenty-eight participants each evaluated 26 lighting conditions—created using four, seven-channel, tunable LED luminaires—in a 3.1 m by 3.7 m room filled with objects selected to cover a range of hue, saturation, and lightness. IES TM-30 fidelity index (Rf) values ranged from 64 to 93, IES TM-30 gamut index (Rg¬) values from 79 to 117, and IES TM-30 Rcs,h1 values (a proxy for gamut shape) from -19% tomore » 26%. All lighting conditions delivered the same nominal illuminance and chromaticity. Participants were asked to rate each condition on eight point semantic differential scales for saturated-dull, normal-shifted, and like-dislike. They were also asked one multiple choice question, classifying the condition as saturated, dull, normal, or shifted. The findings suggest that gamut shape is more important than average gamut for human preference, where reds play a more important role than other hues. Additionally, average fidelity alone is a poor predictor of human perceptions, although Rf was somewhat better than CIE Ra. The most preferred source had a CIE Ra value of 68, and 9 of the top 12 rated products had a CIE Ra value of 73 or less, which indicates that the commonly used criteria of CIE Ra ≥ 80 may be excluding a majority of preferred light sources.« less
Moncayo, Helga; Dapunt, Otto; Moncayo, Roy
2007-08-02
Basal TSH levels reflect the metabolic status of thyroid function, however the definition and interpretation of the basal levels of TSH is a matter of controversial debate. The aim of this study was to evaluate basal TSH levels in relation to the physiological response to i.v. TRH stimulation. A series of 2570 women attending a specialized endocrine unit were evaluated. A standardized i.v. TRH stimulation test was carried out by applying 200 mug of TRH. TSH levels were measured both in the basal and the 30 minute blood sample. The normal response to TRH stimulation had been previously determined to be an absolute value lying between 2.5 and 20 mIU/l. Both TSH values were analyzed by cross tabulation. In addition the results were compared to reference values taken from the literature. Basal TSH values were within the normal range (0.3 to 3.5 mIU/l) in 91,5% of cases, diminished in 3,8% and elevated in 4.7%. Based on the response to TRH, 82.4% were considered euthyroid, 3.3% were latent hyperthyroid, and 14.3% were latent hypothyroid. Combining the data on basal and stimulated TSH levels, latent hypothyroidism was found in the following proportions for different TSH levels: 5.4% for TSH < 2.0 mIU/l, 30.2% for TSH between 2.0 and 3.0 mIU/l, 65,5% for TSH between 3.0 and 3.50 mIU/l, 87.5% for TSH between 3.5 and 4.0 mIU/l, and 88.2% for TSH between 4 and 5 mIU/l. The use of an upper normal range for TSH of 2.5 mIU/l, as recommended in the literature, misclassified 7.7% of euthyroid cases. Our analysis strategy allows us to delineate the predictive value of basal TSH levels in relation to latent hypothyroidism. A grey area can be identified for values between 3.0 and 3.5 mIU/l.
No evidence of insulin resistance in normal weight vegetarians. A case control study.
Valachovicová, Martina; Krajcovicová-Kudlácková, Marica; Blazícek, Pavel; Babinská, Katarína
2006-02-01
Diets rich in carbohydrates with a low glycemic index and with high fiber content are associated with flat post-prandial rises of blood glucose, minimal post-prandial insulin secretion and maintenance of insulin sensitivity. Protective food commodities in the prevention of cardiovascular disease, insulin resistance syndrome or diabetes are crucial components of the vegetarian diet. Insulin resistance values were assessed in relation to different nutrition. Metabolic abnormality is a predictor of age-related diseases and can be more pronounced in obese subjects. Insulin resistance values in normal weight subjects of two different nutritional habits were correlated with age. Fasting concentrations of glucose and insulin as well as calculated values of insulin resistance IR (HOMA) were assessed in two nutritional groups of apparently healthy adult subjects (age range 19 - 64 years) with normal weight (body mass index 18.6 - 25.0 kg/m(2)): a vegetarian group (95 long-term lacto-ovo-vegetarians; duration of vegetarianism 10.2 +/- 0.5 years) and a non-vegetarian control group (107 subjects of general population on traditional western diet). Intake of energy and main nutrients (fats, saccharides, proteins) was similar in both groups. Glucose and insulin concentrations and IR (HOMA) values were significantly lower in vegetarians (glucose 4.47 +/- 0.05 vs. 4.71 +/- 0.07 mmol/l; insulin 4.96 +/- 0.23 vs. 7.32 +/- 0.41 mU/l; IR (HOMA) 0.99 +/- 0.05 vs. 1.59 +/- 0.10). IR (HOMA) dependence on age was only significant in subjects on a western diet. A significant increase of IR was found already in the age range 31-40 years, compared to vegetarians and it continued in later age decades. Age independent and low insulin resistance values in vegetarians are a consequence of an effective diet prevention by long-term frequent consumption of protective food. Vegetarians had a significantly higher consumption of whole grain products, pulses, products from oat and barley. The results of age independent and low values of insulin resistance document a beneficial effect of long-term vegetarian nutrition in prevention of metabolic syndrome, diabetes and cardiovascular disease.
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
The Quarterly Environmental Data Summary (QEDS) for the fourth quarter of 1997 is prepared in support of the Weldon Spring Site Remedial Action Project Federal Facilities Agreement. The data presented constitute the QEDS. The data were received from the contract laboratories, verified by the Weldon Spring Site verification group and, except for air monitoring data and site KPA generated data (uranium analyses), merged into the data base during the fourth quarter of 1997. Air monitoring data presented are the most recent complete sets of quarterly data. Air data are not stored in the data base and KPA data are notmore » merged into the regular data base. Significant data, defined as data values that have exceeded defined ``above normal`` level 2 values, are discussed in this letter for Environmental Monitoring Plan (EMP) generated data only. Above normal level 2 values are based, in ES and H procedures, on historical high values, DOE Derived Concentration Guides (DCGs), NPDES limits and other guidelines. The procedures also establish actions to be taken in response to such data. Data received and verified during the fourth quarter were within a permissible range of variability except for those which are detailed.« less
Amino acids acting as transmitters in amyotrophic lateral sclerosis (ALS).
Niebroj-Dobosz, I; Janik, P
1999-07-01
In amyotrophic lateral sclerosis (ALS), a neurodegenerative disease of unknown origin, excitotoxic mechanisms are supposed to be involved. Divergent results are, however, presented either because of the heterogeneity of this disease, and/or different methodologies used to evaluate the excitotoxic amino acids content. The results of the most sensitive high performance liquid chromatography (HPLC) techniques with precolumn derivatization of fasting serum and CSF glutamate, aspartate, glycine and gamma-aminobutyric acid (GABA) in mild and severely progressing ALS cases are presented here. We studied 25 ALS patients with different course of the disease and controls, which consisted of 10 cases with other motor neuron diseases and 20 healthy, age-matched subjects. In the ALS patients with a mild course of the disease serum glutamate and aspartate content was either normal or slightly decreased, in all of these cases a rise in GABA and glycine was present. In the severely progressing ALS cases serum glutamate and aspartate was increased. The GABA content was either normal or increased, the glycine level appeared to be either normal or decreased. In CSF the amino acids changes in ALS were less pronounced as compared to serum. The most frequent finding was the increase in GABA concentration both in the mild and the severely progressing group. CSF glutamate in ALS patients with mild course of the disease was decreased, in the severely progressing cases the glutamate level appeared in a broad range from decreased to increased values. CSF aspartate was either normal or elevated, glycine values were present in a broad range from decreased to increased values. In the other tested motor neuron diseases no consistent changes in serum and CSF amino acids concentration was observed. The data from serum and CSF indicate that in ALS an imbalance between excitatory and inhibitory amino acids might be present in the brain, which may be induced in different ways in particular ALS patients. It may be an important factor for the mediation of neurons death.
Chan, J T Y; Omana, D A; Betti, M
2011-05-01
Functional and rheological properties of proteins from frozen turkey breast meat with different ultimate pH at 24 h postmortem (pH(24)) have been studied. Sixteen breast fillets from Hybrid Tom turkeys were initially selected based on lightness (L*) values for each color group (pale, normal, and dark), with a total of 48 breast fillets. Further selection of 8 breast samples was made within each class of meat according to the pH(24). The average L* and pH values of the samples were within the following range: pale (L* >52; pH ≤5.7), normal (46 < L* < 52; 5.9 < pH <6.1), and dark (L* <46; pH ≥6.3), referred to as low, normal, and high pH meat, respectively. Ultimate pH did not cause major changes in the emulsifying and foaming properties of the extracted sarcoplasmic and myofibrillar proteins. An SDS-PAGE profile of proteins from low and normal pH meat was similar, which revealed that the extent of protein denaturation was the same. Low pH meat had the lowest water-holding capacity compared with normal and high pH meat as shown by the increase in cooking loss, which can be explained by factors other than protein denaturation. Gel strength analysis and folding test revealed that gel-forming ability was better for high pH meat compared with low and normal pH meat.Dynamic viscoelastic behavior showed that myosin denaturation temperature was independent of pH(24). Normal and high pH meat had similar hardness, springiness, and chewiness values as revealed by texture profile analysis. The results from this study indicate that high pH meat had similar or better functional properties than normal pH meat. Therefore, high pH meat is suitable for further processed products, whereas low pH meat may need additional treatment or ingredient formulations to improve its functionality.
Archer, Edward; Hand, Gregory A; Hébert, James R; Lau, Erica Y; Wang, Xuewen; Shook, Robin P; Fayad, Raja; Lavie, Carl J; Blair, Steven N
2013-12-01
To validate the PAR protocol, a novel method for calculating population-level estimated energy requirements (EERs) and average physical activity ratio (APAR), in a nationally representative sample of US adults. Estimates of EER and APAR values were calculated via a factorial equation from a nationally representative sample of 2597 adults aged 20 and 74 years (US National Health and Nutrition Examination Survey; data collected between January 1, 2005, and December 31, 2006). Validation of the PAR protocol-derived EER (EER(PAR)) values was performed via comparison with values from the Institute of Medicine EER equations (EER(IOM)). The correlation between EER(PAR) and EER(IOM) was high (0.98; P<.001). The difference between EER(PAR) and EER(IOM) values ranged from 40 kcal/d (1.2% higher than EER(IOM)) in obese (body mass index [BMI] ≥30) men to 148 kcal/d (5.7% higher) in obese women. The 2005-2006 EERs for the US population were 2940 kcal/d for men and 2275 kcal/d for women and ranged from 3230 kcal/d in obese (BMI ≥30) men to 2026 kcal/d in normal weight (BMI <25) women. There were significant inverse relationships between APAR and both obesity and age. For men and women, the APAR values were 1.53 and 1.52, respectively. Obese men and women had lower APAR values than normal weight individuals (P¼.023 and P¼.015, respectively) [corrected], and younger individuals had higher APAR values than older individuals (P<.001). The PAR protocol is an accurate method for deriving nationally representative estimates of EER and APAR values. These descriptive data provide novel quantitative baseline values for future investigations into associations of physical activity and health. Copyright © 2013 Mayo Foundation for Medical Education and Research. Published by Elsevier Inc. All rights reserved.
Reference values for clinical laboratory parameters in young adults in Maputo, Mozambique.
Tembe, Nelson; Joaquim, Orvalho; Alfai, Eunice; Sitoe, Nádia; Viegas, Edna; Macovela, Eulalia; Gonçalves, Emilia; Osman, Nafissa; Andersson, Sören; Jani, Ilesh; Nilsson, Charlotta
2014-01-01
Clinical laboratory reference values from North American and European populations are currently used in most Africans countries due to the absence of locally derived reference ranges, despite previous studies reporting significant differences between populations. Our aim was to define reference ranges for both genders in 18 to 24 year-old Mozambicans in preparation for clinical vaccine trials. A cross-sectional study including 257 volunteers (102 males and 155 females) between 18 and 24 years was performedat a youth clinic in Maputo, Mozambique. All volunteers were clinically healthy and human immunodeficiency virus, Hepatitis B virus and syphilis negative.Median and 95% reference ranges were calculated for immunological, hematological and chemistry parameters. Ranges were compared with those reported based on populations in other African countries and the US. The impact of applying US NIH Division of AIDS (DAIDS) toxicity tables was assessed. The immunology ranges were comparable to those reported for the US and western Kenya.There were significant gender differences in CD4+ T cell values 713 cells/µL in males versus 824 cells/µL in females (p<0.0001). Hematologic values differed from the US values but were similar to reports of populations in western Kenya and Uganda. The lower and upper limits of the ranges for hemoglobin, hematocrit, red blood cells, white blood cells and lymphocytes were somewhat lower than those from these African countries. The chemistry values were comparable to US values, with few exceptions. The upper limits for ALT, AST, bilirubin, cholesterol and triglycerides were higher than those from the US. DAIDStables for adverse events predicted 297 adverse events and 159 (62%) of the volunteers would have been excluded. This study is the first to determine normal laboratory parameters in Mozambique. Our results underscore the necessity of establishing region-specific clinical reference ranges for proper patient management and safe conduct of clinical trials.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Alterio, Daniela; Jereczek-Fossa, Barbara Alicja; University of Milan, Milan
2007-01-01
Purpose: To evaluate the incidence of thyroid disorders and dose distribution to the thyroid in patients treated with radiotherapy for head-and-neck carcinomas. Methods and Materials: A retrospective evaluation of data from 73 patients treated for head-and-neck cancers in our department was performed. Thyroid function was evaluated mainly by the measurement of thyrotropin (thyroid stimulating hormone [TSH]). A retrospective analysis of treatment plans was performed for 57 patients. Percentages of thyroid glandular volume absorbing 10, 30, and 50 Gy (V10, V30, and V50 respectively) were considered for statistical analysis. Results: A majority of patients (61%) had a normal thyroid function whereasmore » 19 patients (26%) had hypothyroidism. Mean thyroid volume was 30.39 cc. Point 3 (located at isthmus) absorbed lower doses compared with other points (p < 0.0001). Median values of V10, V30, and V50 were 92% (range, 57-100%), 75% (range, 28.5-100%), and 35% (range, 3-83%) respectively. Gender was associated with toxicity (presence of any kind of thyroid disorders) (p < 0.05), with females displaying higher levels of TSHr (relative TSH = patient's value/maximum value of the laboratory range) (p = 0.0005) and smaller thyroid volume (p 0.0012) compared with male population. TSHr values were associated with thyroid volume, and the presence of midline shielding block in the anterior field was associated with relative free thyroxine (FT4r = patient's value/maximum value of the laboratory range) values. Conclusions: Gender and thyroid volume seem to play an important role in the occurrence of thyroid toxicity, but further studies on dose-effect relationship for radiotherapy-induced thyroid toxicity are needed.« less
Serum biochemistry of captive and free-ranging gray wolves (Canis lupus)
Constable, Peter; Hinchcliff, Ken; Demma, Nick; Callahan, Margaret; Dale, B.W.; Fox, Kevin; Adams, Layne G.; Wack, Ray; Kramer, Lynn
1998-01-01
Normal serum biochemistry values are frequently obtained from studies of captive sedentary (zoo) or free-ranging (wild) animals. It is frequently assumed that values from these two populations are directly referable to each other. We tested this assumption using 20 captive gray wolves (Canis lupus) in Minnesota, USA, and 11 free-ranging gray wolves in Alaska, USA. Free-ranging wolves had significantly (P<0.05) lower sodium, chloride, and creatine concentrations and significantly higher potassium and blood urea nitrogen (BUN) concentrations; BUN to creatine ratios; and alanine aminotransferase, aspartate aminotransferase, and creatine kinase activities relative to captive wolves. Corticosteroid-induced alkaline phosphatase activity (a marker of stress in domestic dogs) was detected in 3 of 11 free-ranging wolves and in 0 of 20 captive wolves (P = 0.037). This study provides clear evidence that serum biochemical differences can exist between captive and free-ranging populations of one species. Accordingly, evaluation of the health status of an animal should incorporate an understanding of the potential confounding effect that nutrition, activity level, and environmental stress could have on the factor(s) being measured.
Wilson, Raymond C.
1997-01-01
Broad-scale variations in long-term precipitation climate may influence rainfall/debris-flow threshold values along the U.S. Pacific coast, where both the mean annual precipitation (MAP) and the number of rainfall days (#RDs) are controlled by topography, distance from the coastline, and geographic latitude. Previous authors have proposed that rainfall thresholds are directly proportional to MAP, but this appears to hold only within limited areas (< 1?? latitude), where rainfall frequency (#RDs) is nearly constant. MAP-normalized thresholds underestimate the critical rainfall when applied to areas to the south, where the #RDs decrease, and overestimate threshold rainfall when applied to areas to the north, where the #RDs increase. For normalization between climates where both MAP and #RDs vary significantly, thresholds may best be described as multiples of the rainy-day normal, RDN = MAP/#RDs. Using data from several storms that triggered significant debris-flow activity in southern California, the San Francisco Bay region, and the Pacific Northwest, peak 24-hour rainfalls were plotted against RDN values, displaying a linear relationship with a lower bound at about 14 RDN. RDN ratios in this range may provide a threshold for broad-scale regional forecasting of debris-flow activity.
The bleeding time may be longer in children than in adults.
Sanders, J M; Holtkamp, C A; Buchanan, G R
1990-01-01
The bleeding time, the most frequently performed test reflecting in vivo platelet function, is the duration of blood flow from a standardized incision on the volar surface of the forearm. Normal values have been determined in adult subjects, but with the exception of neonates, data on the range of bleeding time values in pediatric patients are unavailable. Standard hematology textbooks imply that bleeding time values in children are similar to those of adults. We have reviewed our 9 years of experience with 137 children (mean age 6.5 years) who were referred for diagnostic evaluation of a bleeding disorder but whose history and physical examination were felt by us to be inconsistent with an abnormality of hemostasis. Bleeding time values in these individuals (mean 6.0 min, 95th percentile 9.0 min) were compared with those of 85 normal adult volunteers (mean 4.4 min, 95th percentile 6.5 min). The Simplate-I disposable device and vertical (perpendicular to elbow crease) incision direction were used in both groups. This difference between the pediatric and adult bleeding time values is statistically significant (p less than 0.0001). Neither age nor sex had a significant effect on the pediatric bleeding time measurements. We conclude that the bleeding time, when performed as described, is longer in children than in adults and that pediatric standards for bleeding time should be used in order to avoid a spurious diagnosis of a primary hemostatic disorder in some normal children.
Normal spinal bone marrow in adults: dynamic gadolinium-enhanced MR imaging.
Montazel, Jean-Luc; Divine, Marine; Lepage, Eric; Kobeiter, Hicham; Breil, Stephane; Rahmouni, Alain
2003-12-01
To determine the patterns of dynamic enhancement of normal spinal bone marrow in adults at gadolinium-enhanced magnetic resonance (MR) imaging and the changes that occur with aging. Dynamic contrast material-enhanced MR imaging of the thoracolumbar spine was performed in 71 patients. The maximum percentage of enhancement (Emax), enhancement slope, and enhancement washout were determined from bone marrow enhancement time curves (ETCs). The bone marrow signal intensity on T1-weighted spin-echo MR images was qualitatively classified into three grade categories. Quantitative ETC values were correlated with patient age and bone marrow fat content grade. Statistical analysis included mean t test comparison, analysis of variance, and regression analysis of the correlations between age and quantitative MR parameters. Emax, slope, and washout varied widely among the patients. Emax values were obtained within 1 minute after contrast material injection and ranged from 0% to 430%. Emax values were significantly higher in patients younger than 40 years than in those aged 40 years or older (P <.001). These values decreased with increasing age in a logarithmic relationship (r = 0.71). Emax values decreased as fat content increased, but some overlap among the fat content grades was noted. Analysis of variance revealed that Emax was significantly related to age (younger than 40 years vs 40 years or older) (P <.001) and fat content grade (P <.001) but not significantly related to sex. Dynamic contrast-enhanced MR imaging patterns of normal spinal bone marrow are dependent mainly on patient age and fat content.
The role of copeptin in patients with subarachnoid haemorrage.
Zissimopoulos, Athanassios; Vogiatzaki, Theodosia; Babatsikou, Fotini; Velissaratou, Marion; Baloka, Lukia; Karathanos, Evangelos; Pistola, Anastasia; Christofis, Xristos; Iatrou, Xristos
2015-01-01
Subarachnoid haemorrhage is responsible to a great extend for the death rate of patients who are hospitalised in intensive care units (ICU) with haemorrhage. The early detection of its severity plays an important role for the resulting health of the patients. Neurohormone Copeptin is the C-end of pro-arginine vasopressin in plasma has been used as a prognostic marker in a number of various illnesses (acute myocardial infarction, heart and renal failure, acute dyspnoea, intracerebral and subarachnoid haemorrhage, ischaemic stroke, liver cirrhosis, acute pancreatitis). However, its prognostic value in subarachnoid haemorrhage has yet to be valued. The aim of our study was to evaluate copeptin plasma values of patients with subarachnoid haemorrhage hospitalised in the ICU, as a prognostic factor for the severity of this disease. We studied 32 patients, 21 male, 11 female, (average age 59±7 years), who were hospitalised in the ICU of Univ. Hospital of Alexandroupolis. Plasma Copeptin values were measured in the Nuclear Medicine Laboratory, with the Radioimmunoassay (RIA) method. The appropriate kit, from Phoenix Pharmaceuticals Inc. (USA), was used. The x(2) student test was used for statistical analysis. The cut-off value of copeptin ranged between 0.4-4.4 pmol/L. 19 patients showed gradual increase of copeptin values, (125-578 pmol/L), with a bad prognosis of the illness (P<0.005). Four of them with extremely high copeptin values died. Decrease of copeptin values for the rest 15 patients were correlated with the improvement of their clinical condition (P<0.005). Eleven patients appeared to have high values, followed by the gradual decrease by a range of 85-12pmol/L, and had a good prognosis of the condition. Two patients with normal values demonstrated to have a good clinical condition. Patients with a gradual increase of copeptin values showed to have bad prognosis of the disease. Four with extremely high copeptin values passed away, while patients with a gradual decrease or a normal amount of copeptin values had good prognosis. It is supported that copeptin values are a reliable prognostic factor in monitoring patients with intracranial haemorrhage.
ERIC Educational Resources Information Center
Dyson, Suzanne; Smith, Elizabeth
2012-01-01
This paper reports on qualitative research with Australian parents concerning their attitudes to sexuality and relationships education, both at home and in school. A wide range of values and attitudes were represented among parents in this study. Regardless of the varying approaches parents used, all participants expressed a desire for their…
Percentile-Based Journal Impact Factors: A Neglected Collection Development Metric
ERIC Educational Resources Information Center
Wagner, A. Ben
2009-01-01
Various normalization techniques to transform journal impact factors (JIFs) into a standard scale or range of values have been reported a number of times in the literature, but have seldom been part of collection development librarians' tool kits. In this paper, JIFs as reported in the Journal Citation Reports (JCR) database are converted to…
Urrechaga, E
2016-12-01
ADAMS ™ A1cHA-8180T is a HPLC system; within 3.5 min, it quantifies HbF, HbA 2 , and HbA 0 and flags abnormal peaks. We evaluate its analytical performance for routine estimation of HbA 2 and HbF, and critical tests were performed for identifying β-thalassemia carriers. Trueness imprecision, carry over, linearity, and effect of anemia were evaluated according to ICLH, ICLS, or manufacture's guidelines. Comparison (ADAMS ™ A1c HA-8160T) was performed by running 400 samples from healthy subjects, 30 alpha and 80 beta carriers (range: 1.9-5.7 %). Trueness - HbA 2 2.7 %, bias 0.81 %; HbA 2 5.8 %, bias 0.38 %. HbA 2 4.0% is not affected by Hb in the range 221-40 g/L. Carry over was negligible. Within run: normal control - CV 1.5 %, high control - CV 0.9 %.Within laboratory: normal control - total CV% 1.59%; high control - 0.92 %. Linearity - y = 1.034x - 0.17, R 2 = 0.998 (range: 2.8-4.8%).Method comparison - y = 0.93x + 0.22, R 2 = 0.997. HbF imprecision CVs between 0.66 and 1.24% and trueness between 0 and 2.8%. Linearity - y = 1.088x - 0.27, R 2 = 0.999 (0.1-5.7%). ADAMS ™ A1c HA-8180T provides a rapid and reliable separation of HbA 2 . The measurement is accurate and reproducible, which is needed because of the slight difference between normal and pathological values. The gap in HbA 2 values between normal subjects and β-thalassemia carriers makes this an appropriate method for rapid screening for carriers. © 2016 John Wiley & Sons Ltd.
NASA Technical Reports Server (NTRS)
Monaghan, R. C.; Friend, E. L.
1973-01-01
Wind-up-turn maneuvers were performed to establish the values of airplane normal force coefficient for buffet onset, wing-rock onset, and buffet loads with various combinations of leading- and trailing-edge flap deflections. Data were gathered at both subsonic and transonic speeds covering a range from Mach 0.64 to Mach 0.92. Buffet onset and buffet loads were obtained from wingtip acceleration and wing-root bending-moment data, and wing-rock onset was obtained from airplane roll rate data. Buffet onset, wing-rock onset, and buffet loads were similarly affected by the various combinations of leading- and training-edge flaps. Subsonically, the 12 deg leading-edge-flap and trailing-edge-flap combination was most effective in delaying buffet onset, wing-rock onset, and equivalent values of buffet loads to a higher value of airplane normal force coefficient. This was the maximum flap deflection investigated. Transonically, however, the optimum leading-edge flap position was generally less than 12 deg.
Aranha, V P; Saxena, S; Moitra, M; Narkeesh, K; Arumugam, N; Samuel, A J
2017-01-01
This study aimed to estimate normative range for reaction time using ruler drop method for school-going South Asian children between 6 and 12 years of age. A cross-sectional study was used to evaluate the reaction time for 204 children. Normal values for each age group were obtained. The results of multiple linear regressions showed a decrease in the reaction time values with age, and a significant change occurring between six and eight years of age. No difference in reaction time was obtained between boys and girls. Ruler drop method is an easy to use test and the results of this study provide a normative data for age groups 6-12 years ranging from 214.2ms to 248.8ms. These values can serve as a reference to screen children with delayed reaction time. Copyright © 2016 Elsevier GmbH. All rights reserved.
19 CFR 351.403 - Sales used in calculating normal value; transactions between affiliated parties.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 19 Customs Duties 3 2010-04-01 2010-04-01 false Sales used in calculating normal value... ADMINISTRATION, DEPARTMENT OF COMMERCE ANTIDUMPING AND COUNTERVAILING DUTIES Calculation of Export Price, Constructed Export Price, Fair Value, and Normal Value § 351.403 Sales used in calculating normal value...
[Pregnancy-specific beta-glycoprotein in the serum of women with a complicated early pregnancy].
Radikov, N
1989-01-01
The author determined pregnancy specific beta 1-glycoprotein in 109 women with threatened early pregnancy as 32 of the women suffered from abortus imminens with several unsuccessful pregnancies in the past as well as 67 women with abortus incipiens with bleeding ex utero. The author established that 87% of women with abortus imminens and preserved pregnancies had values of beta 1-glycoprotein close to those of normal pregnancy for the respective gestational week. 93% of women with abortus incipiens preserved pregnancies till term, but the specific glycoprotein was with in normal ranges. Spontaneous abortion occurred in 7% of women with low values under the 10th percentile. The present study show that examination of pregnancy specific beta 1-glycoprotein in women with threatened early pregnancy is of prognostic significance for the outcome of pregnancy.
Saura, Daniel; Dulgheru, Raluca; Caballero, Luis; Bernard, Anne; Kou, Seisyou; Gonjilashvili, Natalia; Athanassopoulos, George D; Barone, Daniele; Baroni, Monica; Cardim, Nuno; Hagendorff, Andreas; Hristova, Krasimira; Lopez, Teresa; de la Morena, Gonzalo; Popescu, Bogdan A; Penicka, Martin; Ozyigit, Tolga; Rodrigo Carbonero, Jose David; Van De Veire, Nico; Von Bardeleben, Ralph Stephan; Vinereanu, Dragos; Zamorano, Jose Luis; Gori, Ann-Stephan; Cosyns, Bernard; Donal, Erwan; Habib, Gilbert; Addetia, Karima; Lang, Roberto M; Badano, Luigi P; Lancellotti, Patrizio
2017-02-01
To report normal reference ranges for echocardiographic dimensions of the proximal aorta obtained in a large group of healthy volunteers recruited using state-of-the-art cardiac ultrasound equipment, considering different measurement conventions, and taking into account gender, age, and body size of individuals. A total of 704 (mean age: 46.0 ± 13.5 years) healthy volunteers (310 men and 394 women) were prospectively recruited from the collaborating institutions of the Normal Reference Ranges for Echocardiography (NORRE) study. A comprehensive echocardiographic examination was obtained in all subjects following pre-defined protocols. Aortic dimensions were obtained in systole and diastole, following both the leading-edge to leading-edge and the inner-edge to inner-edge conventions. Diameters were measured at four levels: ventricular-arterial junction, sinuses of Valsalva, sino-tubular junction, and proximal tubular ascending aorta. Measures of aortic root in the short-axis view following the orientation of each of the three sinuses were also performed. Men had significantly larger body sizes when compared with women, and showed larger aortic dimensions independently of the measurement method used. Dimensions indexed by height and body surface area are provided, and stratification by age ranges is also displayed. In multivariable analysis, the independent predictors of aortic dimensions were age, gender, and height or body surface area. The NORRE study provides normal values of proximal aorta dimensions as assessed by echocardiography. Reference ranges for different anatomical levels using different (i) measurement conventions and (ii) at different times of the cardiac cycle (i.e. mid-systole and end-diastole) are provided. Age, gender, and body size were significant determinants of aortic dimensions. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.
Ventilation by high-frequency chest wall compression in dogs with normal lungs.
Zidulka, A; Gross, D; Minami, H; Vartian, V; Chang, H K
1983-06-01
In 6 anesthetized and paralyzed supine dogs, ventilation by high-frequency chest wall compression (HFCWC) was accomplished by a piston pump rapidly oscillating the pressure in a modified double blood pressure cuff wrapped around the lower thorax. Testing applied frequencies at 3, 5, 8, and 11 Hz, applied peak cuff pressures ranged from 30 to 230 cmH2O. This produced swings of esophageal pressure as high as 18 cmH2O and peak oscillatory air flow ranging from 0.7 to 1.6 L/s. Oscillatory tidal volume declined with increasing frequency and ranged from a mean of 61 to 45 ml. After 30 min of applied HFCWC, arterial blood gas determinations revealed a mean PaCO2 of 29.3 mmHg at 5 Hz, 35 mmHg at 3 Hz, 36 mmHg at 8 Hz, and 51 mmHg at 11 Hz. Mean PaO2 improved from ventilator control values at 3 Hz, remained unchanged at 5 and 8 Hz, and declined at 11 Hz. In 2 dogs breathing spontaneously, HFCWC applied at 5 and 11 Hz resulted in a reduction in spontaneous minute ventilation, mainly by a reduction in spontaneous tidal volume, whereas arterial blood gas values changed slightly. One dog ceased to breath spontaneously within 5 min of application of HFCWC as the PaCO2 fell below control values. We conclude that in dogs with normal lungs, HFCWC may assist spontaneous ventilation. In paralyzed dogs, HFCWC may be of sufficient magnitude to cause hyperventilation.
Olivotto, Iacopo; Maron, Barry J; Appelbaum, Evan; Harrigan, Caitlin J; Salton, Carol; Gibson, C Michael; Udelson, James E; O'Donnell, Christopher; Lesser, John R; Manning, Warren J; Maron, Martin S
2010-07-15
In hypertrophic cardiomyopathy (HCM), the clinical significance attributable to the broad range of left ventricular (LV) systolic function, assessed as the ejection fraction (EF), is incompletely resolved. We evaluated the EF using cardiovascular magnetic resonance (CMR) imaging in a large cohort of patients with HCM with respect to the clinical status and evidence of left ventricular remodeling with late gadolinium enhancement (LGE). CMR imaging was performed in 310 consecutive patients, aged 42 +/- 17 years. The EF in patients with HCM was 71 +/- 10% (range 28% to 89%), exceeding that of 606 healthy controls without cardiovascular disease (66 +/- 5%, p <0.001). LGE reflecting LV remodeling showed an independent, inverse relation to the EF (B-0.69, 95% confidence interval -0.86 to -0.52; p <0.001) and was greatest in patients with an EF <50%, in whom it constituted a median value of 29% of the LV volume (interquartile range 16% to 40%). However, the substantial subgroup with low-normal EF values of 50% to 65% (n = 45; 15% of the whole cohort), who were mostly asymptomatic or mildly symptomatic (37 or 82% with New York Heart Association functional class I to II), showed substantial LGE (median 5% of LV volume, interquartile range 2% to 10%). This overlapped with the subgroup with systolic dysfunction and significantly exceeded that of patients with an EF of 66% to 75% and >75% (median 2% of the LV volume, interquartile range 1.5% to 4%; p <0.01). In conclusion, in a large cohort of patients with HCM, a subset of patients with low-normal EF values (50% to 65%) was identified by contrast-enhanced CMR imaging as having substantial degrees of LGE, suggesting a transition phase, potentially heralding advanced LV remodeling and systolic dysfunction, with implications for clinical surveillance and management. Copyright (c) 2010. Published by Elsevier Inc.
Nelson, Winnie W; Milentijevic, Dejan; Wang, Li; Baser, Onur; Damaraju, C V; Schein, Jeffrey R
2016-12-01
Limited information exists regarding the relationship between international normalized ratio (INR) control/stability and the discontinuation of warfarin therapy among patients with nonvalvular atrial fibrillation (NVAF). This study evaluated the association between INR stabilization and warfarin discontinuation and assessed INR patterns before and after INR stabilization among patients (≥18 years) with NVAF who newly initiated warfarin (Veterans Health Administration datasets; October 1, 2007 through September 30, 2012). Achievement of INR stabilization (≥3 consecutive in-range therapeutic INR measurements ≥7 days apart) was examined from warfarin initiation through the end of warfarin exposure. Proportion of time in therapeutic range during warfarin exposure was calculated (Rosendaal method) and categorized as at least 60% or less than 60%. Among 34 346 patients, 49.4% achieved INR stabilization (mean time to stabilization, 98 days). Approximately 40% of INR values were out-of-range, even after achieving stabilization. During 30 days following an INR 4.0 or higher, patients had more INR testing than the overall mean (2.51 vs. 1.67 tests). Warfarin discontinuation was 4.2 times more likely among patients without INR stabilization versus those with INR stabilization (P < 0.00001). Patients with poor INR control (time in therapeutic range <60%) were 1.76 times more likely to discontinue warfarin within 1 year (P < 0.0001). INR stabilization is a better predictor of warfarin discontinuation than poor INR control. Improved approaches are necessary to maintain appropriate anticoagulation levels among patients with NVAF.
Dimitriadis, Stavros I.; Zouridakis, George; Rezaie, Roozbeh; Babajani-Feremi, Abbas; Papanicolaou, Andrew C.
2015-01-01
Mild traumatic brain injury (mTBI) may affect normal cognition and behavior by disrupting the functional connectivity networks that mediate efficient communication among brain regions. In this study, we analyzed brain connectivity profiles from resting state Magnetoencephalographic (MEG) recordings obtained from 31 mTBI patients and 55 normal controls. We used phase-locking value estimates to compute functional connectivity graphs to quantify frequency-specific couplings between sensors at various frequency bands. Overall, normal controls showed a dense network of strong local connections and a limited number of long-range connections that accounted for approximately 20% of all connections, whereas mTBI patients showed networks characterized by weak local connections and strong long-range connections that accounted for more than 60% of all connections. Comparison of the two distinct general patterns at different frequencies using a tensor representation for the connectivity graphs and tensor subspace analysis for optimal feature extraction showed that mTBI patients could be separated from normal controls with 100% classification accuracy in the alpha band. These encouraging findings support the hypothesis that MEG-based functional connectivity patterns may be used as biomarkers that can provide more accurate diagnoses, help guide treatment, and monitor effectiveness of intervention in mTBI. PMID:26640764
Generalized energy detector for weak random signals via vibrational resonance
NASA Astrophysics Data System (ADS)
Ren, Yuhao; Pan, Yan; Duan, Fabing
2018-03-01
In this paper, the generalized energy (GE) detector is investigated for detecting weak random signals via vibrational resonance (VR). By artificially injecting the high-frequency sinusoidal interferences into an array of GE statistics formed for the detector, we show that the normalized asymptotic efficacy can be maximized when the interference intensity takes an appropriate non-zero value. It is demonstrated that the normalized asymptotic efficacy of the dead-zone-limiter detector, aided by the VR mechanism, outperforms that of the GE detector without the help of high-frequency interferences. Moreover, the maximum normalized asymptotic efficacy of dead-zone-limiter detectors can approach a quarter of the second-order Fisher information for a wide range of non-Gaussian noise types.
Fetal nasal bone length and Down syndrome during the second trimester in a Chinese population.
Hung, Jeng-Hsiu; Fu, Chong Yau; Chen, Chih-Yao; Chao, Kuan-Chong; Hung, Jamie
2008-08-01
The purpose of the present study was to build a database of reference ranges of fetal nasal bone length (NBL) in a Chinese population. The accuracy rate of detecting Down syndrome was also analyzed using fetal NBL as a marker. The control group of fetuses included 342 normal singleton pregnancies with no chromosomal or congenital anomalies. The present study was a cross-section study and the control group was used to construct percentile values of NBL from 13 to 29 gestational weeks of age. Two-dimensional ultrasonography was used for the nasal bone studies. Measurements of NBL were collected and each fetus contributed a single value to the reference sample. During the study period, 14 fetuses with Down syndrome were examined. Measurement of fetal NBL was made during amniocentesis, with gestational age ranging from 13 to 19 weeks. From 342 normal fetuses with gestational age ranging from 13 to 29 weeks, reference ranges of NBL were constructed. The reference ranges were constructed from the 100(1 - p)% reference range: Y +/- Zp x square root sigma 2, where Y = 25 - exp(3.58 - 0.044 x t + 0.0006 x t2), with Y being the fitted mean of regression model and t being gestational age (weeks). Using fetal NBL, the regression model was Pr(Down syndrome) = exp(W)/ [1 + exp(W)], where W = 0.62-4.80 x NBL (multiples of the median) in predicting Down syndrome. Fetal NBL was found to have a sensitivity and specificity of 0.78 and 0.78, respectively, in predicting Down syndrome in the second trimester of pregnancy. Fetal NBL measurement can provide a simple and useful algorithm to predict Down syndrome during the second trimester of pregnancy.
Gotsch, Francesca; Romero, Roberto; Kusanovic, Juan Pedro; Chaiworapongsa, Tinnakorn; Dombrowski, Michael; Erez, Offer; Than, Nandor Gabor; Mazaki-Tovi, Shali; Mittal, Pooja; Espinoza, Jimmy; Hassan, Sonia S
2009-01-01
OBJECTIVE An anti-angiogenic state has been described in patients with preeclampsia, small for gestational age (SGA) fetuses and fetal death, and changes in the concentration of circulating angiogenic and anti-angiogenic factors can precede the clinical recognition of preeclampsia and small for gestational age by several weeks. Gene deletion studies demonstrate that a selective group of endothelial growth factors are required for vascular development, including members of the vascular endothelial growth factor (VEGF) family, as well as Angiopoietin-1 and Angiopoietin-2, both ligands for the tyrosine kinase endothelial cell receptor Tie-2. These angiogenic factors have been proposed to promote angiogenesis in a coordinated and complementary fashion. Soluble Tie-2 (sTie-2) is the soluble form of the Tie-2 receptor which is detectable in biological fluids. The purpose of this study was to determine whether patients with preeclampsia and mothers who deliver a small for gestational age neonate have changes in the plasma concentrations of sTie-2. STUDY DESIGN This cross-sectional study included patients in the following groups: 1) non-pregnant women (n=40); 2) women with normal pregnancies (n=135); 3) patients with preeclampsia (n=112); and 4) patients who delivered a small for gestational age (SGA) neonate (n=53). Maternal plasma concentrations of sTie-2 were measured by a sensitive immunoassay. Parametric statistics were used for analysis. RESULTS 1) The median maternal plasma concentration of sTie-2 was lower in normal pregnant women than in non-pregnant women [median 16.0 ng/ml (range 5.0–71.6) vs. median 20.7 ng/ml (range 10.8–52.4), respectively; p=0.01)]; 2) Plasma sTie-2 concentrations in normal pregnancy changed significantly as a function of gestational age; 3) Patients with preeclampsia and those who delivered SGA neonates had a lower median maternal plasma concentration of sTie-2 than those with a normal pregnancy [Preeclampsia: median 14.9 ng/ml (range 4.9–67.3); SGA: median 10.9 ng/ml (range 5.1–29.1); Normal pregnancy: median 16.0 ng/ml (range 5.0–71.6); p=0.048 and p<0.001, respectively]; 4) Patients with SGA neonates had a lower median plasma concentration of sTie-2 than that of those with preeclampsia [median 10.9 ng/ml (range 5.1–29.1) vs. median 14.9 ng/ml (range 4.9–67.3), respectively; p<0.001)]; and 5) Patients with early-onset preeclampsia (≤34 weeks) had lower concentrations of sTie-2 than women with late-onset preeclampsia (>34 weeks) [median of delta values: −0.13 ng/ml (range −0.47–0.58) vs. median of delta values: −0.09 ng/ml (range: −0.60–0.58), respectively; p=0.043]. In contrast, there were no significant differences in the maternal plasma sTie-2 concentration between women with severe and mild preeclampsia (p=0.6). CONCLUSION Patients with preeclampsia and those with SGA fetuses have lower median plasma concentrations of soluble Tie-2 than women with normal pregnancies. PMID:18570117
Performance of 1.15-pressure-ratio fan stage at several rotor blade setting angles with reverse flow
NASA Technical Reports Server (NTRS)
Kovich, G.; Moore, R. D.
1976-01-01
A 51 cm diameter low pressure ratio fan stage was tested in reverse flow. Survey flow data were taken over the range of rotative speed from 50 percent to 100 percent design speed at several rotor blade setting angles through both flat and feather pitch. Normal flow design values of pressure ratio and weight flow were 1.15 and 29.9 kg/sec with a rotor tip speed of 243.8 m/sec. The maximum thrust in reverse flow was 52.5 percent of design thrust in normal flow.
NASA Technical Reports Server (NTRS)
Johnson, Joseph L.
1954-01-01
An investigation has been conducted to determine the static stability and control and damping in roll and yaw of a 0.13-scale model of the Convair XFY-1 airplane with propellers off from 0 deg to 90 deg angle of attack. The tests showed that a slightly unstable pitch-up tendency occurred simultaneously with a break in the normal-force curve in the angle-of-attack range from about 27 deg to 36 deg. The top vertical tail contributed positive values of static directional stability and effective dihedral up to an angle of attack of about 35 deg. The bottom tail contributed positive values of static directional stability but negative values of effective dihedral throughout the angle-of-attack range. Effectiveness of the control surfaces decreased to very low values at the high angles of attack, The model had positive damping in yaw and damping in roll about the body axes over the angle-of-attack range but the damping in yaw decreased to about zero at 90 deg angle of attack.
Simulations of large acoustic scintillations in the straits of Florida.
Tang, Xin; Tappert, F D; Creamer, Dennis B
2006-12-01
Using a full-wave acoustic model, Monte Carlo numerical studies of intensity fluctuations in a realistic shallow water environment that simulates the Straits of Florida, including internal wave fluctuations and bottom roughness, have been performed. Results show that the sound intensity at distant receivers scintillates dramatically. The acoustic scintillation index SI increases rapidly with propagation range and is significantly greater than unity at ranges beyond about 10 km. This result supports a theoretical prediction by one of the authors. Statistical analyses show that the distribution of intensity of the random wave field saturates to the expected Rayleigh distribution with SI= 1 at short range due to multipath interference effects, and then SI continues to increase to large values. This effect, which is denoted supersaturation, is universal at long ranges in waveguides having lossy boundaries (where there is differential mode attenuation). The intensity distribution approaches a log-normal distribution to an excellent approximation; it may not be a universal distribution and comparison is also made to a K distribution. The long tails of the log-normal distribution cause "acoustic intermittency" in which very high, but rare, intensities occur.
Poulin, Patrick; Hop, Cornelis Eca; Salphati, Laurent; Liederer, Bianca M
2013-04-01
Understanding drug distribution and accumulation in tumors would be informative in the assessment of efficacy in targeted therapy; however, existing methods for predicting tissue drug distribution focus on normal tissues and do not incorporate tumors. The main objective of this study was to describe the relationships between tissue-plasma concentration ratios (Kp ) of normal tissues and those of subcutaneous xenograft tumors under nonsteady-state conditions, and establish regression equations that could potentially be used for the prediction of drug levels in several human tumor xenografts in mouse, based solely on a Kp value determined in a normal tissue (e.g., muscle). A dataset of 17 compounds was collected from the literature and from Genentech. Tissue and plasma concentration data in mouse were obtained following oral gavage or intraperitoneal administration. Linear regression analyses were performed between Kp values in several normal tissues (muscle, lung, liver, or brain) and those in human tumor xenografts (CL6, EBC-1, HT-29, PC3, U-87, MCF-7-neo-Her2, or BT474M1.1). The tissue-plasma ratios in normal tissues reasonably correlated with the tumor-plasma ratios in CL6, EBC-1, HT-29, U-87, BT474M1.1, and MCF-7-neo-Her2 xenografts (r(2) in the range 0.62-1) but not with the PC3 xenograft. In general, muscle and lung exhibited the strongest correlation with tumor xenografts, followed by liver. Regression coefficients from brain were low, except between brain and the glioblastoma U-87 xenograft (r(2) in the range 0.62-0.94). Furthermore, reasonably strong correlations were observed between muscle and lung and between muscle and liver (r(2) in the range 0.67-0.96). The slopes of the regressions differed depending on the class of drug (strong vs. weak base) and type of tissue (brain vs. other tissues and tumors). Overall, this study will contribute to our understanding of tissue-plasma partition coefficients for tumors and facilitate the use of physiologically based pharmacokinetics (PBPK) modeling for chemotherapy in oncology studies. © 2013 Wiley Periodicals, Inc. and the American Pharmacists Association J Pharm Sci 102:1355-1369, 2013. Copyright © 2013 Wiley Periodicals, Inc.
Cihangiroglu, M M; Ozturk-Isik, E; Firat, Z; Kilickesmez, O; Ulug, A M; Ture, U
2017-03-01
The goal of this study was to compare diffusion-weighted magnetic resonance imaging (DW-MRI) using high b-value (b=3000s/mm 2 ) to DW-MRI using standard b-value (b=1000s/mm 2 ) in the preoperative grading of supratentorial gliomas. Fifty-three patients with glioma had brain DW-MRI at 3T using two different b-values (b=1000s/mm 2 and b=3000s/mm 2 ). There were 35 men and 18 women with a mean age of 40.5±17.1 years (range: 18-79 years). Mean, minimum, maximum, and range of apparent diffusion coefficient (ADC) values for solid tumor ROIs (ADC mean , ADC min , ADC max , and ADC diff ), and the normalized ADC (ADC ratio ) were calculated. A Kruskal-Wallis statistic with Bonferroni correction for multiple comparisons was applied to detect significant ADC parameter differences between tumor grades by including or excluding 19 patients with an oligodendroglioma. Receiver operating characteristic curve analysis was conducted to define appropriate cutoff values for grading gliomas. No differences in ADC derived parameters were found between grade II and grade III gliomas. Mean ADC values using standard b-value were 1.17±0.27×10 -3 mm 2 /s [range: 0.63-1.61], 1.05±0.22×10 -3 mm 2 /s [range: 0.73-1.33], and 0.86±0.23×10 -3 mm 2 /s [range: 0.52-1.46] for grades II, III and IV gliomas, respectively. Using high b-value, mean ADC values were 0.89±0.24×10 -3 mm 2 /s [range: 0.42-1.25], 0.82±0.20×10 -3 mm 2 /s [range: 0.56-1.10], and 0.59±0.17×10 -3 mm 2 /s [range: 0.40-1.01] for grades II, III and IV gliomas, respectively. ADC mean , ADC ratio , ADC max , and ADC min were different between grade II and grade IV gliomas at both standard and high b-values. Differences in ADC mean , ADC max , and ADC diff were found between grade III and grade IV only using high b-value. ADC parameters derived from DW-MRI using a high b-value allows a better differential diagnosis of gliomas, especially for differentiating grades III and IV, than those derived from DW-MRI using a standard b-value. Copyright © 2016 Éditions françaises de radiologie. Published by Elsevier Masson SAS. All rights reserved.
Contributions of microgravity test results to the design of spacecraft fire-safety systems
NASA Technical Reports Server (NTRS)
Friedman, Robert; Urban, David L.
1993-01-01
Experiments conducted in spacecraft and drop towers show that thin-sheet materials have reduced flammability ranges and flame-spread rates under quiescent low-gravity environments (microgravity) compared to normal gravity. Furthermore, low-gravity flames may be suppressed more easily by atmospheric dilution or decreasing atmospheric total pressure than their normal-gravity counterparts. The addition of a ventilating air flow to the low-gravity flame zone, however, can greatly enhance the flammability range and flame spread. These results, along with observations of flame and smoke characteristics useful for microgravity fire-detection 'signatures', promise to be of considerable value to spacecraft fire-safety designs. The paper summarizes the fire detection and suppression techniques proposed for the Space Station Freedom and discusses both the application of low-gravity combustion knowledge to improve fire protection and the critical needs for further research.
Normal CD4 Count Range among Healthy Nigerian Population in Ilorin.
Afolabi, J K; Fadeyi, A; Desalu, O O; Durotoye, I A; Fawibe, A E; Adeboye, M A N; Olawumi, H O; Babatunde, A S; Ernest, S K; Aderibigbe, S A; Saadu, R; Salami, A K; Aboyeji, A P
For the establishment and monitoring of the immune status, CD4 count is critical. To determine the CD4 count range of apparently healthy Nigerians resident in Ilorin and compare with the national value. An automated blood analyzer was used to determine the full blood count and CD4 count. The percentage of CD4 count was derived by using other variables. Of the 1205 participants, the reference CD4 count (percentage of CD4) range for adult was 400 to 1288 cells/mm 3 (19%-48%) and for children was 582 to 3652 cells/mm 3 (17%-50%). CD4 count and percentage of CD4 were significantly ( P = .001) higher in females than in males, and the CD4 count declined significantly with increasing age ( r = -.174, P ≤ .0001). The percentage of CD4 count shows less variation with age ( r = -.051, P = .076). Adult residents of Ilorin had significantly lower absolute mean CD4 count (808 ± 260) than that of the national reference values of 847.0 ± 307.0 cells/mm 3 ( P = .001). We therefore advocate the use of CD4 count range derived in this study is lower than that of the national reference values.
Kumar, Vikash; Dhabalia, Jayesh V.; Nelivigi, Girish G.; Punia, Mahendra S.; Suryavanshi, Manav
2009-01-01
Objectives: The objective of this study was measurement of urine flow parameters by a non invasive urodynamic test. Variation of flow rates based on voided volume, age, and gender are described. Different nomograms are available for different populations and racial differences of urethral physiology are described. Currently, there has been no study from the Indian population on uroflow parameters. So the purpose of this study was to establish normal reference ranges of maximum and average flow rates, to see the influence of age, gender, and voided volume on flow rates, and to chart these values in the form of a nomogram. Methods: We evaluated 1,011 uroflowmetry tests in different age groups in a healthy population (healthy relatives of our patients) 16-50 year old males, >50 year old males, 5-15 year old children, and >15 year pre-menopausal and post-menopausal females. The uroflowmetry was done using the gravitimetric method. Flow chart parameters were analyzed and statistical calculations were used for drawing uroflow nomograms. Results: Qmax values in adult males were significantly higher than in the elderly and Qmax values in young females were significantly higher than in young males. Qmax values in males increased with age until 15 years old; followed by a slow decline until reaching 50 years old followed by a rapid decline after 50 years old even after correcting voided volume. Qmax values in females increased with age until they reached age 15 followed by decline in flow rate until a pre-menopausal age followed by no significant decline in post-menopausal females. Qmax values increased with voided volume until 700 cc followed by a plateau and decline. Conclusions: Qmax values more significantly correlated with age and voided volume than Qavg. Nomograms were drawn in centile form to provide normal reference ranges. Qmax values in our population were lower than described in literature. Patients with voided volume up to 50 ml could be evaluated with a nomogram. PMID:19955668
Modis, Laszlo; Hassan, Ziad; Szalai, Eszter; Flaskó, Zsuzsanna; Berta, Andras; Nemeth, Gabor
2016-01-01
AIM To analyse ocular biomechanical properties, central corneal thickness (CCT) and intraocular pressure (IOP) in post-keratoplasty eyes, as compared to normal subjects, with a new Scheimpflug-based technology. Moreover, biomechanical data were correlated with the size and age of the donor and recipient corneas. METHODS Measurements were conducted on 46 eyes of 46 healthy patients without any corneal pathology (age: 53.83±20.8y) and 30 eyes of 28 patients after penetrating keratoplasty (age: 49.43±21.34y). Ten biomechanical parameters, the CCT and IOP were recorded by corneal visualization scheimpflug technology (CorVis ST) using high-speed Scheimpflug imaging. Keratometry values were also recorded using Pentacam HR system. Scheimpflug measurements were performed after 43.41±40.17mo (range: 11-128mo) after the keratoplasty and after 7.64±2.34mo (range: 5-14mo) of suture removal. RESULTS Regarding the device-specific biomechanical parameters, the highest concavity time and radius values showed a significant decrease between these two groups (P=0.01 and P<0.001). None of other biomechanical parameters disclosed a significant difference. The CCT showed a significant difference between post-keratoplasty eyes as compared to normal subjects (P=0.003) using the CorVis ST device. The IOP was within the normal range in both groups (P=0.84). There were no significant relationships between the keratometric data, the size of the donor and recipient, age of the donor and recipient and biomechanical properties obtained by CorVis ST. CONCLUSION The ocular biomechanics remain stable after penetrating keratoplasty according to the CorVis ST measurements. Only two from the ten device-specific parameters have importance in the follow-up period after penetrating keratoplasty. PMID:26949641
[Estimation of the atrioventricular time interval by pulse Doppler in the normal fetal heart].
Hamela-Olkowska, Anita; Dangel, Joanna
2009-08-01
To assess normative values of the fetal atrioventricular (AV) time interval by pulse-wave Doppler methods on 5-chamber view. Fetal echocardiography exams were performed using Acuson Sequoia 512 in 140 singleton fetuses at 18 to 40 weeks of gestation with sinus rhythm and normal cardiac and extracardiac anatomy. Pulsed Doppler derived AV intervals were measured from left ventricular inflow/outflow view using transabdominal convex 3.5-6 MHz probe. The values of AV time interval ranged from 100 to 150 ms (mean 123 +/- 11.2). The AV interval was negatively correlated with the heart rhythm (p<0.001). Fetal heart rate decreased as gestation progressed (p<0.001). Thus, the AV intervals increased with the age of gestation (p=0.007). However, in the same subgroup of the fetal heart rate there was no relation between AV intervals and gestational age. Therefore, the AV intervals showed only the heart rate dependence. The 95th percentiles of AV intervals according to FHR ranged from 135 to 148 ms. 1. The AV interval duration was negatively correlated with the heart rhythm. 2. Measurement of AV time interval is easy to perform and has a good reproducibility. It may be used for the fetal heart block screening in anti-Ro and anti-La positive pregnancies. 3. Normative values established in the study may help obstetricians in assessing fetal abnormalities of the AV conduction.
Fajfrová, Jana; Pavlík, Vladimír; Psutka, Jan; Husarová, Michaela; Krutišová, Pavla; Fajfr, Miroslav
2016-05-01
Obesity is currently considered to be the most frequent metabolic disease worldwide, not only in developed but also in developing countries. The aim of this work was to describe the development of health status in soldiers of the Armed Forces of the Czech Republic (ACR) and to emphasizethe markers of non-communicable diseases. Our study describes the anthropometric and biochemical parameters of a large group of Czech Army professional soldiers. Data were obtained over a period of 11 years. During the monitored period, from 1999 to 2009, military physicians carried out on the average 6,360 examinations on professional soldiers per year and monitored their health and nutritional status with the aim of preventing the risk factors of non-communicable diseases. These examinations are compulsory for all professional soldiers at the age of 25, 30, 33, and 36 years. From the age of 39, these examinations are carried out every year till the end of their career. Besides taking personal histories and carrying out standard physical examinations, blood was taken for biochemical examination. The following anthropometric parameters were monitored: body constitution using body mass index (BMI) and waist circumference. Our study describes only part of the data concerning anthropometric and biochemical parameters of professional soldiers which were obtained over a period of 11 years. Average BMI values in men were in the overweight range (26.5-27 kg/m2). Average values of waist circumference, however, ranged from 91.9 cm to 93.4 cm. Between the first and the last year of monitoring a statistically significant decrease in these values ranging from 93.4 ± 9.8 cm to 92.7 ± 9.5 cm (p < 0.001) was observed. All monitored anthropometric parameters in female professional soldiers were within normal limits. During the monitored period the proportion of overweight men gradually increased from 52% to 57.1% (p < 0.001). There were no statistically significant changes in the prevalence of obesity in men (12-15%). Average glycaemia levels were within normal range in both men and women. A statistically significant decrease in these levels, however, was observed in men (from 5.1 ± 0.9 mmol/L to 4.8 ± 0.7 mmol/L (p < 0.001) and in women (from 4.9 ± 0.6 mmol/L to 4.6 ± 0.6 mmol/L (p < 0.001). Concerning the lipid profile in men, a significant decrease in average values of total cholesterol, triglycerides and LDL cholesterol was observed; from 5.5 ± 1.1 mmol/L to 5.1 ± 1.0 mmol/L (p < 0.001), from 2.0 ± 1.6 mmol/L to 1.6 ± 1.2 mmol/L (p < 0.001) and from 3.4 ± 1.1 mmol/L to 3.2 ± 0.9 mmol/L (p < 0.001), respectively. During the monitored period only one-third of military professionals had normal body weight. More favorable situation was in female professional soldiers, two-thirds of them had normal body weight during the monitored period. Additionally, the increase in the number of individuals with BMI values in the overweight range was observed. Although the number of overweight soldiers was overestimated as a result of the inclusion of individuals with increased body weight due to well-developed musculature, the number of overweight and obese soldiers is still high.
Neves, Laura A; Rodrigues, Janaína M; Daroda, Romeu J; Silva, Paulo R M; Ferreira, Alexandre A; Aranda, Donato A G; Eberlin, Marcos N; Fasciotti, Maíra
2015-11-15
Brazil is the largest producer of sugar cane bioethanol in the world. Isotope ratio mass spectrometry (IRMS) is the technique of choice to certify the origin/raw materials for ethanol production, but the lack of certified reference materials (CRMs) for accurate measurements of δ(13) C values traceable to Vienna Pee Dee Belemnite (VPDB), the international zero point for (13) C/(12) C measurements, certified and compatible with gas chromatography (GC)/IRMS instruments may compromise the accuracy of δ(13) C determinations. We evaluated the influence of methods for the calibration and normalization of raw δ(13) C values of ethanol samples. Samples were analyzed by GC/C/IRMS using two different GC columns. Different substances were used as isotopic standards for the working gas calibration. The δ(13) C values obtained with the three methods of normalization were statistically compared with those obtained with elemental analyzer (EA)/IRMS, since the δ(13) C results obtained using EA are traceable to VPDB via the NBS 22 reference material. It was observed that both the isotopic reference material for CO2 calibration and the GC column have a major effect on the δ(13) C measurements, leading to a bias of almost 2-3 ‰ in the δ(13) C values. All three methods of normalization were equivalent in performance, enabling an improvement in the GC/C/IRMS accuracy, compared with the EA/IRMS reference values for the samples. All the methods of CO2 calibration, chromatography and normalization presented in this work demonstrated several sources of traceability and accuracy loss for the determination of δ(13) C values in ethanol fuel samples by GC/C/IRMS. This work has also shown the importance of using proper CRMs traceable to VPBD that should be compatible and certified using GC/C/IRMS, ideally in a wide range of δ(13) C values. This is important not only for bioethanol fuel samples, but also for many analytes commonly analyzed by IRMS. Copyright © 2015 John Wiley & Sons, Ltd.
NASA Astrophysics Data System (ADS)
Bellier, Olivier; Zoback, Mary Lou
1995-06-01
The NW to north-trending Walker Lane zone (WLZ) is located along the western boundary of the northern Basin and Range province with the Sierra Nevada. This zone is distinguished from the surrounding Basin and Range province on the basis of irregular topography and evidence for both normal and strike-slip Holocene faulting. Inversion of slip vectors from active faults, historic fault offsets, and earthquake focal mechanisms indicate two distinct Quaternary stress regimes within the WLZ, both of which are characterized by a consistent WNW σ3 axis; these are a normal faulting regime with a mean σ3 axis of N85°±9°W and a mean stress ratio (R value) (R=(σ2-σ1)/(σ3-σ1)) of 0.63-0.74 and a younger strike-slip faulting regime with a similar mean σ3 axis (N65° - 70°W) and R values ranging between ˜ 0.1 and 0.2. This younger regime is compatible with historic fault offsets and earthquake focal mechanisms. Both the extensional and strike-slip stress regimes reactivated inherited Mesozoic and Cenozoic structures and also produced new faults. The present-day strike-slip stress regime has produced strike-slip, normal oblique-slip, and normal dip-slip historic faulting. Previous workers have explained the complex interaction of active strike-slip, oblique, and normal faulting in the WLZ as a simple consequence of a single stress state with a consistent WNW σ3 axis and transitional between strike-slip and normal faulting (maximum horizontal stress approximately equal to vertical stress, or R ≈ 0 in both regimes) with minor local fluctuations. The slip data reported here support previous results from Owens Valley that suggest deformation within temporally distinct normal and strike-slip faulting stress regimes with a roughly constant WNW trending σ3 axis (Zoback, 1989). A recent change from a normal faulting to a strike-slip faulting stress regime is indicated by the crosscutting striae on faults in basalts <300,000 years old and is consistent with the dominantly strike-slip earthquake focal mechanisms and the youngest striae observed on faults in Plio-Quaternary deposits. Geologic control on the timing of the change is poor; it is impossible to determine if there has been a single recent absolute change or if there is, rather, an alternating or cyclical variation in stress magnitudes. Our slip data, in particular, the cross-cutting normal and strike-slip striae on the same fault plane, are inconsistent with postulated simple strain partitioning of deformation within a single regional stress field suggested for the WLZ by Wesnousky and Jones [1994]. The location of the WLZ between the deep-seated regional extension of the Basin and Range and the right-lateral strike-slip regional tectonics of the San Andreas fault zone is probably responsible for the complex interaction of tectonic regimes in this transition zone. In early to mid-Tertiary time the WLZ appears to have had a similarly complex deformational history, in this case as a back arc or intra-arc region, accommodating at least part of the right-lateral component of oblique convergence as well as a component of extension.
Lee, Han-Seung; Ismail, Mohamed A.; Woo, Young-Je; Min, Tae-Beom; Choi, Hyun-Kook
2014-01-01
Structural lightweight concrete (SLWC) has superior properties that allow the optimization of super tall structure systems for the process of design. Because of the limited supply of lightweight aggregates in Korea, the development of structural lightweight concrete without lightweight aggregates is needed. The physical and mechanical properties of specimens that were cast using normal coarse aggregates and different mixing ratios of foaming agent to evaluate the possibility of creating structural lightweight concrete were investigated. The results show that the density of SLWC decreases as the dosage of foaming agent increases up to a dosage of 0.6%, as observed by SEM. It was also observed that the foaming agent induced well separated pores, and that the size of the pores ranged from 50 to 100 μm. Based on the porosity of concrete specimens with foaming agent, compressive strength values of structural lightweight foam concrete (SLWFC) were obtained. It was also found that the estimated values from proposed equations for compressive strength and modulus of elasticity of SLWFC, and values obtained by actual measurements were in good agreement. Thus, this study confirms that new structural lightweight concrete using normal coarse aggregates and foaming agent can be developed successfully. PMID:28788691
Shim, J H; Lee, Y S; Kim, M R; Lee, C J; Kim, I S
2003-10-10
We examined a Keele injector for sample introduction for gas chromatographic analysis of vinclozolin treated in lettuces. Samples in milligram quantity were introduced into a glass tube in a Keele injector at a gas chromatograph injection port. The glass tube was then crushed to allow the sample to carry onto a capillary column in a normal manner. The standard calibration curve for quantitative detection of vinclozolin was obtained by determining vinclozolin spiked in samples at variable concentrations. The calibration curve showed a linear response to vinclozolin ranging from 0.05 to 1.0 microg/g, giving a slope value of 174.8, the y-intercept value of -2.8146 and the mean r2-value of 0.9994. Limit of quantification for vinclozolin was 0.05 microg/g by this method, comparable to 0.01 microg/g by a normal injector. When samples treated previously with vinclozolin were determined by the Keele injector, vinclozolin was found to be about 30% lower as compared to a normal method, suggesting about 70% recovery of the spiked vinclozolin by the Keele injector. From these results, the Keele injector was suggested to be potential for sample introduction in gas chromatographic analysis of vinclozolin in lettuce samples.
Differences among Myopes, Emmetropes, and Hyperopes.
1980-04-01
parasympathetic activity (see Wenger & Cullen, 1965). The second index, Cw, is a coherence statistic (a normalized function with values ranging between zero...farther distances. ACKNOWLEDGMENT The literature search and the statistical analyses presented in this report were conducted at New Mexico State...in infant and child. New York: Paul B. Hoeber, 1949. Gould, G. M. Diagnosis, diseases and therapeutics of ametropia . British Journal of Ophthalmology
Automated estimation of abdominal effective diameter for body size normalization of CT dose.
Cheng, Phillip M
2013-06-01
Most CT dose data aggregation methods do not currently adjust dose values for patient size. This work proposes a simple heuristic for reliably computing an effective diameter of a patient from an abdominal CT image. Evaluation of this method on 106 patients scanned on Philips Brilliance 64 and Brilliance Big Bore scanners demonstrates close correspondence between computed and manually measured patient effective diameters, with a mean absolute error of 1.0 cm (error range +2.2 to -0.4 cm). This level of correspondence was also demonstrated for 60 patients on Siemens, General Electric, and Toshiba scanners. A calculated effective diameter in the middle slice of an abdominal CT study was found to be a close approximation of the mean calculated effective diameter for the study, with a mean absolute error of approximately 1.0 cm (error range +3.5 to -2.2 cm). Furthermore, the mean absolute error for an adjusted mean volume computed tomography dose index (CTDIvol) using a mid-study calculated effective diameter, versus a mean per-slice adjusted CTDIvol based on the calculated effective diameter of each slice, was 0.59 mGy (error range 1.64 to -3.12 mGy). These results are used to calculate approximate normalized dose length product values in an abdominal CT dose database of 12,506 studies.
Determination of Earth rotation by the combination of data from different space geodetic systems
NASA Technical Reports Server (NTRS)
Archinal, Brent Allen
1987-01-01
Formerly, Earth Rotation Parameters (ERP), i.e., polar motion and UTI-UTC values, have been determined using data from only one observational system at a time, or by the combination of parameters previously obtained in such determinations. The question arises as to whether a simultaneous solution using data from several sources would provide an improved determination of such parameters. To pursue this reasoning, fifteen days of observations have been simulated using realistic networks of Lunar Laser Ranging (LLR), Satellite Laser Ranging (SLR) to Lageos, and Very Long Baseline Interferometry (VLBI) stations. A comparison has been done of the accuracy and precision of the ERP obtained from: (1) the individual system solutions, (2) the weighted means of those values, (3) all of the data by means of the combination of the normal equations obtained in 1, and (4) a grand solution with all the data. These simulations show that solutions done by the normal equation combination and grand solution methods provide the best or nearly the best ERP for all the periods considered, but that weighted mean solutions provide nearly the same accuracy and precision. VLBI solutions also provide similar accuracies.
Measurement of humerus and radius bone mineral content in the term and preterm infant
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vyhmeister, N.R.; Linkhart, T.A.
1988-07-01
We compared two anatomic sites for single-photon absorptiometric measurement of bone mineral content (BMC) in term and preterm infants. The distal one third of the radius and the midportion of the humerus were evaluated for measurements of BMC with an unmodified, commercially available bone densitometer. We assessed reproducibility of BMC and bone width (BW) measurements and defined normal at-birth ranges of BMC, BW, and BMC/BW ratio for infants with gestational ages of 24 to 42 weeks. Humerus BMC correlated with gestational age, birth weight, and BW of patients and did not differ from humerus BMC values determined over the samemore » range of gestational ages at another center. Representative serial measurements of two very low birth weight (VLBW) infants are presented to demonstrate the feasibility of using humerus BMC in longitudinal studies to assess changes in bone mineralization. We conclude that bone densitometer measurements of mid-humerus BMC can be successfully performed and are preferable to similar measurements of the radius for VLBW infants. Normal humerus BMC values were defined for use in diagnosis and evaluation of the efficacy of treatment in VLBW infants who are at high risk of developing osteopenia of prematurity.« less
Short-duration respirometry underestimates metabolic rate for discontinuous breathers.
Winwood-Smith, Hugh S; White, Craig R
2018-06-07
Metabolic rate is commonly estimated from rates of gas exchange. An underappreciated factor that can influence estimates is patterns of pulmonary respiration. Amphibians display discontinuous respiratory patterns, often including long apnoeas, in addition to cutaneous gas exchange. The contribution of cutaneous exchange increases at low temperatures when metabolic rate is low. Due to the relatively low permeability of skin, measurements that disproportionately capture cutaneous exchange can produce underestimates of metabolic rate. The permeability of amphibian skin to CO 2 is greater than O 2 , therefore calculating the ratio of whole-animal CO 2 emission to O 2 uptake (the respiratory exchange ratio, RER) can be used to avoid underestimates of metabolic rate by ensuring that observed values of RER fall within the normal physiological range (∼0.7 to 1). Using data for cane toads Rhinella marina we show that short-duration measurements lead to underestimates of metabolic rate and overestimates of RER. At low temperatures this problem is exacerbated, requiring over 12 hours for RER to fall within the normal physiological range. Many published values of metabolic rate in animals that utilise cutaneous exchange may be underestimates. © 2018. Published by The Company of Biologists Ltd.
Erhardt, E; Foraita, R; Pigeot, I; Barba, G; Veidebaum, T; Tornaritis, M; Michels, N; Eiben, G; Ahrens, W; Moreno, L A; Kovács, E; Molnár, D
2014-09-01
To establish age- and sex-specific reference values for serum leptin and adiponectin in normal-weight 3.0-8.9-year old European children. Blood samples for hormone analysis were taken from 1338 children of the IDEFICS (Identification and prevention of Dietary- and lifestyle-induced health Effects in Children and infantS) study cohort. Only normal-weight children aged 3.0-8.9 years were included (n=539) in our analysis. Using the General Additive Model for Location Scale and Shape, age- and sex-specific percentiles were derived. The influence of under/overweight and obesity on the proposed reference curves based on normal-weight children was investigated in several sensitivity analyses using the sample without obese children (n=1015) and the whole study sample (n=1338). There was a negative age trend of adiponectin blood levels and a positive trend of leptin levels in boys and girls. Percentiles derived for girls were generally higher than those obtained for boys. The corresponding age-specific differences of the 97th percentile ranged from -2.2 to 4.6 μg ml(-1) and from 2.2 to 4.8 ng ml(-1) for adiponectin and leptin, respectively. According to our knowledge, these are the first reference values of leptin and adiponectin in prepubertal, normal-weight children. The presented adiponectin and leptin reference curves may allow for a more differentiated interpretation of children's hormone levels in epidemiological and clinical studies.
Laugharne, Edward; Bali, Navi; Purushothamdas, Sanjay; Almallah, Faris; Kundra, Rik
2016-01-01
Purpose The purpose of this study was to investigate the impact of varying knee flexion and quadriceps activity on patellofemoral indices measured on magnetic resonance imaging (MRI). Materials and Methods MRI of the knee was performed in 20 patients for indications other than patellar or patellofemoral pathology. Axial and sagittal sequences were performed in full extension of the knee with the quadriceps relaxed, full extension of the knee with the quadriceps contracted, 30° flexion of the knee with the quadriceps relaxed, and 30° flexion with the quadriceps contracted. Bisect offset, patella tilt angle, Insall-Salvati ratio and Caton-Deschamps index were measured. Results With the knee flexed to 30° and quadriceps relaxed, the mean values of patellar tilt angle, bisect offset, Insall-Salvati ratio and Caton-Deschamps index were all within normal limits. With the knee extended and quadriceps contracted, the mean patellar tilt angle (normal value, <15°) was 14.6° and the bisect offset (normal value, <65%) was 65%, while the Caton-Deschamps index was 1.34 (normal range, 0.6 to 1.3). With the knee extended and quadriceps relaxed, the mean Caton-Deschamps index was 1.31. Conclusions MRI scanning of the knee in extension with the quadriceps contracted leads to elevated patellofemoral indices. MRI taken with the knee in 30° of flexion allows more reliable assessment of the patellofemoral joint and minimises the confounding effect of quadriceps contraction. PMID:27894177
Liu, Fang-fang; Zhai, Zhen-guo; Yang, Yuan-hua; Wang, Jun; Wang, Chen
2013-06-25
To evaluate the dynamic changes of inflammation-related indices in blood during the development of venous thromboembolism (VTE) and the association between these indices and VTE. A total of 95 VTE hospitalized patients(41 males,54 females) were recruited from Department of Respiratory and Critical Care Medicine, Beijing Chaoyang Hospital from January 2010 to December 2010. Comparisons of inflammation-related indices including white blood cell (WBC), neutrophil (NE), fibrinogen (FBG), C-reactive protein (CRP) and erythrocyte sedimentation rate (ESR) were conducted between VTE patients and normal ranges. And the dynamic changes of these indices during the development of VTE were evaluated. Then they were divided into subgroups according to disease stage, gender, age, VTE type, body mass index, smoking status and clinical manifestations. And statistical analyses were performed to elucidate the associations between these indices and VTE. The levels of NE and CRP in VTE patients (0.72, 15.0 mg/L) and ESR in male VTE patients (20.0 mm/1 h) were elevated compared with normal ranges; while WBC (male 7.27×10(9)/L, female 8.67×10(9)/L), FBG (male 3621 mg/L, female 3201 mg/L) and female ESR (19.5 mm/1 h) in VTE patients were within the normal ranges. The level of CRP was higher in acute (mean rank order value: 49.72) and sub-acute (mean rank order value: 44.80) VTE patients than chronic VTE patients (mean rank order value: 30.25). The level of FBG, CRP and ESR in patients ≥ 50 years old increased versus those <50 years old (mean rank order values 48.83 vs 34.53, 44.32 vs 28.90 and 45.95 vs 27.84 respectively), the patients whose body mass index (BMI) <25 kg/m(2) had higher WBC level than those whose BMI ≥ 25 kg/m(2) (mean rank order values 52.96 vs 36.46); smoking VTE patients had elevated FBG and CRP levels than non-smoking VTE patients (mean rank order values 57.75 vs 42.69 and 53.92 vs 37.75 respectively); compared with those without clinical manifestations of periphery pulmonary artery involved, the patients with clinical manifestations had higher levels of FBG, CRP and ESR (mean rank order values 59.24 vs 37.39, 52.68 vs 33.19 and 50.08 vs 36.55 respectively). The above differences had statistical significance (all P < 0.05). Some inflammation-related indices frequently used in clinical settings become elevated in VTE patients. Part of these indices show higher levels in VTE acute and sub-acute stages, and in older, non-obese, smoking and periphery pulmonary artery involved VTE patients.
NASA Technical Reports Server (NTRS)
Heine, John J. (Inventor); Clarke, Laurence P. (Inventor); Deans, Stanley R. (Inventor); Stauduhar, Richard Paul (Inventor); Cullers, David Kent (Inventor)
2001-01-01
A system and method for analyzing a medical image to determine whether an abnormality is present, for example, in digital mammograms, includes the application of a wavelet expansion to a raw image to obtain subspace images of varying resolution. At least one subspace image is selected that has a resolution commensurate with a desired predetermined detection resolution range. A functional form of a probability distribution function is determined for each selected subspace image, and an optimal statistical normal image region test is determined for each selected subspace image. A threshold level for the probability distribution function is established from the optimal statistical normal image region test for each selected subspace image. A region size comprising at least one sector is defined, and an output image is created that includes a combination of all regions for each selected subspace image. Each region has a first value when the region intensity level is above the threshold and a second value when the region intensity level is below the threshold. This permits the localization of a potential abnormality within the image.
Scanning laser polarimetry in eyes with exfoliation syndrome.
Dimopoulos, Antonios T; Katsanos, Andreas; Mikropoulos, Dimitrios G; Giannopoulos, Theodoros; Empeslidis, Theodoros; Teus, Miguel A; Holló, Gábor; Konstas, Anastasios G P
2013-01-01
To compare retinal nerve fiber layer thickness (RNFLT) of normotensive eyes with exfoliation syndrome (XFS) and healthy eyes. Sixty-four consecutive individuals with XFS and normal office-time intraocular pressure (IOP) and 72 consecutive healthy controls were prospectively enrolled for a cross-sectional analysis in this hospital-based observational study. The GDx-VCC parameters (temporal-superior-nasal-inferior-temporal [TSNIT] average, superior average, inferior average, TSNIT standard deviation (SD), and nerve fiber indicator [NFI]) were compared between groups. Correlation between various clinical parameters and RNFLT parameters was investigated with Spearman coefficient. The NFI, although within normal limits for both groups, was significantly greater in the XFS group compared to controls: the respective median and interquartile range (IQR) values were 25.1 (22.0-29.0) vs 15.0 (12.0-20.0), p<0.001. In the XFS group, all RNFLT values were significantly lower compared to controls (p<0.001). However, they were all within the normal clinical ranges for both groups: TSNIT average median (IQR): 52.8 (49.7-55.7) vs 56.0 (53.0-59.3) µm; superior average mean (SD): 62.3 (6.7) vs 68.8 (8.2) µm; inferior average mean (SD): 58.0 (7.2) vs 64.8 (7.7) µm, respectively. TSNIT SD was significantly lower in the XFS group, median (IQR): 18.1 (15.4-20.4) vs 21.0 (18.4-23.8), p<0.001. There was no systematic relationship between RNFLT and visual acuity, cup-to-disc ratio, IOP, central corneal thickness, Humphrey mean deviation, and pattern standard deviation in either group. Compared to control eyes, polarimetry-determined RNFLT was lower in XFS eyes with normal IOP. Therefore, close monitoring of RNFLT may facilitate early identification of those XFS eyes that convert to exfoliative glaucoma.
Period for Normalization of Voice Acoustic Parameters in Indian Pediatric Cochlear Implantees.
Joy, Jeena V; Deshpande, Shweta; Vaid, Dr Neelam
2017-05-01
The purpose of this study was to investigate the duration required by children with cochlear implants to approximate the norms of voice acoustic parameters. The study design is retrospective. Thirty children with cochlear implants (chronological ages ranging between 4.1 and 6.7 years) were divided into three groups, based on the postimplantation duration. Ten normal-hearing children (chronological ages ranging between 4 and 7 years) were selected as the control group. All implanted children underwent an objective voice analysis using Dr. Speech software (Tiger DRS, Inc., Seattle, WA, USA) at 6 months and at 1 and 2 years of implant use. Voice analysis was done for the children in the control group and means were derived for all the parameters analyzed to obtain the normal values. Habitual fundamental frequency (HFF), jitter (frequency variation), and shimmer (amplitude variation) were the voice acoustic parameters analyzed for the vowels |a|, |i|, and |u|. The obtained values of these parameters were then compared with the norms. HFF for the children with implant use for 6 months and 1 year did significantly differ from the control group. However, there was no significant difference (P > 0.5) observed in the children with implant use for 2 years, thus matching the norms. Jitter and shimmer showed a significant difference (P < 0.5) even at 2 years of implant use when compared with the control group. The findings of the study divulge that children with cochlear implants approximate age-matched normal-hearing kids with respect to the voice acoustic parameter of HFF by 2 years of implant use. However, jitter and shimmer were not found to stabilize for the duration studied. Copyright © 2017 The Voice Foundation. Published by Elsevier Inc. All rights reserved.
19 CFR 351.406 - Calculation of normal value if sales are made at less than cost of production.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 19 Customs Duties 3 2010-04-01 2010-04-01 false Calculation of normal value if sales are made at less than cost of production. 351.406 Section 351.406 Customs Duties INTERNATIONAL TRADE ADMINISTRATION... Price, Fair Value, and Normal Value § 351.406 Calculation of normal value if sales are made at less than...
Estimation of value at risk and conditional value at risk using normal mixture distributions model
NASA Astrophysics Data System (ADS)
Kamaruzzaman, Zetty Ain; Isa, Zaidi
2013-04-01
Normal mixture distributions model has been successfully applied in financial time series analysis. In this paper, we estimate the return distribution, value at risk (VaR) and conditional value at risk (CVaR) for monthly and weekly rates of returns for FTSE Bursa Malaysia Kuala Lumpur Composite Index (FBMKLCI) from July 1990 until July 2010 using the two component univariate normal mixture distributions model. First, we present the application of normal mixture distributions model in empirical finance where we fit our real data. Second, we present the application of normal mixture distributions model in risk analysis where we apply the normal mixture distributions model to evaluate the value at risk (VaR) and conditional value at risk (CVaR) with model validation for both risk measures. The empirical results provide evidence that using the two components normal mixture distributions model can fit the data well and can perform better in estimating value at risk (VaR) and conditional value at risk (CVaR) where it can capture the stylized facts of non-normality and leptokurtosis in returns distribution.
Time for a change to assess and evaluate body temperature in clinical practice.
Sund-Levander, Märtha; Grodzinsky, Ewa
2009-08-01
The definition of normal body temperature as 37 degrees C still is considered the norm worldwide, but in practice there is a widespread confusion of the evaluation of body temperature, especially in elderly individuals. In this paper, we discuss the relevance of normal body temperature as 37 degrees C and consequences in clinical practice. Our conclusion is that body temperature should be evaluated in relation to the individual variability and that the best approach is to use the same site, and an unadjusted mode without adjustments to other sites. If the baseline value is not known, it is important to notice that frail elderly individuals are at risk of a low body temperature. In addition, what should be regarded as fever is closely related to what is considered as normal body temperature. That is, as normal body temperature shows individual variations, it is reasonable that the same should hold true for the febrile range.
NASA Astrophysics Data System (ADS)
Harden, J. W.; Loisel, J.; Hugelius, G.; Sulman, B. N.; Bond-Lamberty, B. P.; Abramoff, R. Z.; Malhotra, A.; Gill, A. L.
2017-12-01
Soils support ecological and human systems by providing a physical and biogeochemical basis for plant growth, ecological functions, water quality, and water storage, and by providing services and functions needed for economic development, human well-being, and conservation of natural resources. Quantitative evaluation of soil services, however, is inconsistent and poorly communicated, in part because we lack a scientific, unified basis for evaluating soils and their potential for serving our needs. We introduce an index of soil service (SSI) in which multiple services are numerically or quantitatively assessed, normalized to a unit-less scale for purposes of intercomparability, and evaluated for a given site or region. Services include organic matter and/or organic carbon storage; plant productivity; CO2 or GHG exchange with the atmosphere; water storage capacity; and nutrient storage and/or availability. The status of SSI can be evaluated by individual services or by a composite index that combines multiple services. The status can be monitored over time; and key services that are more highly valued for a given soil can be weighted accordingly in comparison to other services. As a first step, existing data for each service are captured from a literature and data review in order to establish the full range of values. A site value establishes the ranking relative to the full range. Key services are weighted according to local values. A final index is the sum of the normalized, weighted products. Metrics can be updated and adapted as new data or services are discovered or recognized. Metrics can be used to compare among sites, regions, or time periods.
[Effect of vitamin D deficiency on hypocalcaemia after total thyroidectomy due to benign goitre].
Díez, Manuel; Vera, Cristina; Ratia, Tomás; Diego, Lucía; Mendoza, Fernando; Guillamot, Paloma; San Román, Rosario; Mugüerza, José M; Rodríguez, Angel; Medina, Carlos; Gómez, Beatriz; Granell, Javier
2013-04-01
The purpose of this study was to analyse the relationship between preoperative serum levels of vitamin D and postoperative hypocalcaemia after total thyroidectomy. A prospective observational study was conducted on 113 patients treated by total thyroidectomy due to benign disease. Preoperative vitamin D serum levels and postoperative albumin-corrected calcium and parathormone (PTH) levels were determined. Sensitivity, specificity, positive predictive value and negative predictive value of vitamin D and PTH levels, respectively, in the diagnosis of postoperative hypocalcaemia were calculated. Hypocalcaemia was diagnosed in 44 (38.9%) patients. Vitamin D levels were significantly higher in the group of patients with normal postoperative calcium (median: 25.4pg/mL; range: 4-60), compared to those who developed hypocalcaemia (median: 16.4pg/mL; range: 6.3-46.9) (P=.001). Postoperative hypocalcaemia was more frequent in patients with vitamin D < 30ng/mL (39/78) (50%), than among those with normal levels (5/35) (14.2%) (P=.001). Sensitivity, specificity, positive predictive value and negative predictive value were 88% and 68%, 43% and 82%, 50% and 71%, and 85% and 80% for vitamin D and PTH, respectively. Vitamin D and PTH showed independent prognostic values on the risk of hypocalcaemia. The OR associated with vitamin D < 30ng/mL was 4.25 (95% CI: 1.31-13.78) (P=.016), and the OR of PTH<13pg/mL was 15.4 (95% CI: 4.83-49.1) (P<.001). Vitamin D deficiency is a risk factor of hypocalcaemia after total thyroidectomy for benign goitre. The vitamin D level provides independent prognostic information, which is complementary to that given by PTH. Copyright © 2012 AEC. Published by Elsevier Espana. All rights reserved.
Shear-wave elastography of the testis in the healthy man - determination of standard values.
Trottmann, M; Marcon, J; D'Anastasi, M; Bruce, M F; Stief, C G; Reiser, M F; Buchner, A; Clevert, D A
2016-01-01
Real-time shear-wave elastography (SWE) is a newly developed technique for the sonographic quantification of tissue elasticity, which already is used in the assessment of breast and thyroid lesions. Due to limited overlying tissue, the testes are ideally suited for assessment using shear wave elastography. To our knowledge, no published data exist on real-time SWE of the testes. Sixty six male volunteers (mean age 51.86±18.82, range 20-86) with no known testicular pathology underwent normal B-mode sonography and multi-frame shear-wave elastography of both testes using the Aixplorer ® ultrasound system (SuperSonic Imagine, Aix en Provence, France). Three measurements were performed for each testis; one in the upper pole, in the middle portion and in the lower pole respectively. The results were statistically evaluated using multivariate analysis. Mean shear-wave velocity values were similar in the inferior and superior part of the testicle (1.15 m/s) and were significantly lower in the centre (0.90 m/s). These values were age-independent. Testicular stiffness was significantly lower in the upper pole than in the rest of the testis with increasing volume (p = 0.007). Real-time shear-wave elastography proved to be feasible in the assessment of testicular stiffness. It is important to consider the measurement region as standard values differ between the centre and the testicular periphery. Further studies with more subjects may be required to define the normal range of values for each age group. Useful clinical applications could include the diagnostic work-up of patients with scrotal masses or male infertility.
Moen, Kent G; Brezova, Veronika; Skandsen, Toril; Håberg, Asta K; Folvik, Mari; Vik, Anne
2014-09-01
The aim of this study was to explore the prognostic value of visible traumatic axonal injury (TAI) loads in different MRI sequences from the early phase after adjusting for established prognostic factors. Likewise, we sought to explore the prognostic role of early apparent diffusion coefficient (ADC) values in normal-appearing corpus callosum. In this prospective study, 128 patients (mean age, 33.9 years; range, 11-69) with moderate (n = 64) and severe traumatic brain injury (TBI) were examined with MRI at a median of 8 days (range, 0-28) postinjury. TAI lesions in fluid-attenuated inversion recovery (FLAIR), diffusion-weighted imaging (DWI), and T2*-weighted gradient echo (T2*GRE) sequences were counted and FLAIR lesion volumes estimated. In patients and 47 healthy controls, mean ADC values were computed in 10 regions of interests in the normal-appearing corpus callosum. Outcome measure was the Glasgow Outcome Scale-Extended (GOS-E) at 12 months. In patients with severe TBI, number of DWI lesions and volume of FLAIR lesions in the corpus callosum, brain stem, and thalamus predicted outcome in analyses with adjustment for age, Glasgow Coma Scale score, and pupillary dilation (odds ratio, 1.3-6.9; p = <0.001-0.017). The addition of Rotterdam CT score and DWI lesions in the corpus callosum yielded the highest R2 (0.24), compared to all other MRI variables, including brain stem lesions. For patients with moderate TBI only the number of cortical contusions (p = 0.089) and Rotterdam CT score (p = 0.065) tended to predict outcome. Numbers of T2*GRE lesions did not affect outcome. Mean ADC values in the normal-appearing corpus callosum did not differ from controls. In conclusion, the loads of visible TAI lesions in the corpus callosum, brain stem, and thalamus in DWI and FLAIR were independent prognostic factors in patients with severe TBI. DWI lesions in the corpus callosum were the most important predictive MRI variable. Interestingly, number of cortical contusions in MRI and CT findings seemed more important for patients with moderate TBI.
Brain, Keith L; Kay, Jonathan; Shine, Brian
2006-11-01
Despite the rarity of pheochromocytoma, diagnosis is important because of the dangers of uncontrolled severe hypertension and the availability of very effective surgical treatment. Urinary or plasma catecholamines or catecholamine derivatives are commonly used to screen for pheochromocytomas before imaging, but data from 24-h urinary metanephrine results, patient age, and sex may better predict tumors in populations with a low pretest probability. We retrospectively studied outcomes of an unselected population (1819 patients) referred to a tertiary hospital laboratory for urinary metanephrine testing and investigated the usefulness of some simple derivative measures for detecting pheochromocytoma. We normalized values for urinary 24-h excretion of metanephrine, normetanephrine, and 3-methoxytyramine by dividing by an age- and sex-specific reference range. We then compared pheochromocytoma prediction by the use of products of these normalized measures with the gold standard of biopsy-confirmed tumor. The product of the excretion of normalized metanephrine (nMAD) and normalized normetanephrine (nNMT) (nMAD.nNMT) was a highly sensitive (100%) and specific (99.1%) measure, yielding a positive predictive value of 82%. ROC curves were not improved by including the normalized 3-methoxytyramine concentrations in the product. The test for nMAD.nNMT gave higher sensitivity and specificity than the tests for either substance alone. The test for nMAD.nNMT is a useful measure for identifying pheochromocytoma in a population with a low pretest probability.
Boretti, Felicitas S; Sieber-Ruckstuhl, Nadja S; Favrot, Claude; Lutz, Hans; Hofmann-Lehmann, Regina; Reusch, Claudia E
2006-12-01
To evaluate the use of recombinant human (rh) thyroid-stimulating hormone (TSH) in dogs with suspected hypothyroidism. 64 dogs with clinical signs of hypothyroidism. Dogs received rhTSH (75 microg/dog, IV) at a dose independent of their body weight. Blood samples were taken before and 6 hours after rhTSH administration for determination of total serum thyroxine (T(4)) concentration. Dogs were placed into 1 of 3 groups as follows: those with normal (ie, poststimulation values indicative of euthyroidism), unchanged (ie, poststimulation values indicative of hypothyroidism; no thyroid gland stimulation), or intermediate (ie, poststimulation values between unchanged and normal values) post-TSH T(4) concentrations. Serum canine TSH (cTSH) concentration was determined in prestimulation serum (ie, before TSH administration). 14, 35, and 15 dogs had unchanged, normal, and intermediate post-TSH T(4) concentrations, respectively. Basal T(4) and post-TSH T(4) concentrations were significantly different among groups. On the basis of basal serum T(4) and cTSH concentrations alone, 1 euthyroid (normal post-TSH T(4), low basal T(4), and high cTSH concentrations) and 1 hypothyroid dog (unchanged post-TSH T(4) concentration and low to with-in reference range T(4) and cTSH concentrations) would have been misinterpreted as hypothyroid and euthyroid, respectively. Nine of the 15 dogs with intermediate post-TSHT(4) concentrations had received medication known to affect thyroid function prior to the test, and 2 of them had severe nonthyroidal disease. The TSH-stimulation test with rhTSH is a valuable diagnostic tool to assess thyroid function in selected dogs in which a diagnosis of hypothyroidism cannot be based on basal T(4) and cTSH concentrations alone.
Fattach, Hassan El; Dohan, Anthony; Guerrache, Youcef; Dautry, Raphael; Boudiaf, Mourad; Hoeffel, Christine; Soyer, Philippe
2015-08-01
To qualitatively and quantitatively analyze the presentation of intrahepatic and hilar mass-forming cholangiocarcinoma with diffusion-weighted magnetic resonance imaging (DW-MRI). Twenty-eight patients with histopathologically proven mass-forming cholangiocarcinoma (hilar, n=17; intrahepatic, n=11) underwent hepatic DW-MRI at 1.5-T using free-breathing acquisition and three b-values (0,400,800s/mm(2)). Cholangiocarcinomas were evaluated qualitatively using visual analysis of DW-MR images and quantitatively with conventional ADC and normalized ADC measurements using liver and spleen as reference organs. All cholangiocarcinomas (28/28; 100%) were visible on DW-MR images. DW-MRI yielded best conspicuity of cholangiocarcinomas than the other MRI sequences (P<0.001). Seven cholangiocarcinomas (7/11; 64%) showed hypointense central area on DW-MR images. Conventional ADC value of cholangiocarcinomas (1.042×10(-3)mm(2)/s±0.221×10(-3)mm(2)/s; range: 0.616×10(-3)mm(2)/s to 2.050×10(-3)mm(2)/s) was significantly lower than that of apparently normal hepatic parenchyma (1.362×10(-3)mm(2)/s±0.187×10(-3)mm(2)/s) (P<0.0001), although substantial overlap was found. No significant differences in ADC and normalized ADC values were found between intrahepatic and hilar cholangiocarcinomas. The use of normalized ADC using the liver as reference organ resulted in the most restricted distribution of ADC values of cholangiocarcinomas (variation coefficient=16.6%). There is a trend towards a common appearance of intrahepatic and hilar mass-forming cholangiocarcinomas on DW-MRI but variations may be observed. Familiarity with these variations may improve the diagnosis of mass-forming cholangiocarcinoma. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Micropuncture studies of the recovery phase of myohemoglobinuric acute renal failure in the rat
Oken, Donald E.; DiBona, Gerald F.; McDonald, Franklin D.
1970-01-01
Micropuncture studies of the recovery phase of glycerol-induced myohemoglobinuric acute renal failure were performed in rats whose blood urea nitrogen (BUN) had fallen at least 20% below its peak value. The glomerular filtration rate (GFR) of individual nephrons in a single kidney in the recovery period generally either was in the normal range or minimal. Each animal's BUN concentration at the time of the study was inversely related to the proportion of functioning surface nephrons, but did not correlate with individual nephron GFR values. Proximal tubule fractional water absorption was significantly depressed as manifested by both depressed inulin (TF/P) values and supernormal volumes of collections, a finding which, in the absence of a urea-induced osmotic diuresis, suggests impaired sodium transport by the damaged nephron. The mean proximal tubule hydrostatic pressure in recovery was normal and there was little variation in pressure among functioning nephrons. It is concluded that recovery from this model of acute renal failure reflects the progressive recruitment of increasing numbers of functioning nephrons. The recovery of individual nephron glomerular filtration, once begun, was rapid and complete. No evidence could be adduced that the gradual return of renal function towards normal reflects a slow release of tubular obstruction or repair of disrupted tubular epithelium. Rather, recovery appeared to be directly attributable to the return of an adequate effective glomerular filtration pressure. Significant limitation in proximal tubule water absorption persisted after individual nephron GFR had returned to normal or supernormal values in this model of experimental acute renal failure in the rat, a finding which readily accounts for the diuresis associated with the recovery phase of this syndrome. PMID:5443173
Surface emissivity of a reinforced carbon composite material with an oxidation-inhibiting coating
NASA Technical Reports Server (NTRS)
Wakefield, R. M.
1973-01-01
Total effective emissivity and spectral emissivity over the wavelength range of 0.65 to 6.3 microns were determined for temperatures from 1300 t0 2250 deg K. A multi channel radiometer was used in the arcjet and laboratory tests. The black-body-hole method was used to independently check radiometer results. The results show the silicon-carbide coated reinforced carbon composite material is a nongray radiator. The total effective emissivity and the spectral emissivity at 0.65 micron both decreased with increasing temperature, respectively, from approximately 0.8 to 0.6, and from 0.4 to 0.25, over the temperature range. The emissivity values were the same when the sample was viewed normal to the surface or at a 45 deg angle. Recommended emissivity values are presented.
Turner, Claudia; Carrara, Verena; Thien, Naw Aye Mya; Paw, Naw Moo Ku; Rijken, Marcus; McGready, Rose; Nosten, François
2013-06-14
Identifying unwell neonates, particularly in the first week of life, is often subjective. If normal values are known, calculating the weight lost or gained from birth weight can be a useful adjunct in the evaluation of the health of a neonate. Serial body weights of well, term, breast fed infants who were attending for routine follow up, were recorded at the Shoklo Malaria Research Unit clinic in Maela Camp for displaced persons on the Thailand Myanmar border. Newborn examination was routine. Weight loss, expressed as percent weight lost from birth weight, and weight gain, expressed as a velocity (g/kg/day), was calculated for the first seven days of life. The results from normal birth weight infants, low birth weight infants (<2.5 kg) and small for gestational age infants (SGA) were examined. In the first week of life there were no significant differences in weight gained or lost across the three study groups. The maximum weight lost was 4.4% (95% CI 4.1 - 4.6%), which occurred on day three. Weight gain ranged from 13 g/kg/day [95% CI 10 - 16] on day four to 18 g/kg/day [95% CI 15 - 20] on days six and seven. Use of these normal values for weight gain and loss, allows infants falling outside of the expected range (95% CI) to be easily identified and subsequently highlighted as needing further medical review.
Transcutaneous oximetry: normal values for the lower limb.
Blake, Denise F; Young, Derelle A; Brown, Lawrence H
2014-09-01
Current guidelines for transcutaneous oximetry measurement (TCOM) for the lower limb define tissue hypoxia as a transcutaneous oxygen partial pressure < 40 mmHg. Values obtained with some newer machines and current research bring these reference values into question. To determine 'normal' TCOM values for the lower limb in healthy, non-smoking adults using the TCM400 oximeter with tc Sensor E5250. Thirty-two healthy, non-smoking volunteers had TCOM performed at six positions on the lower leg and foot. Measurements were taken with subjects lying supine breathing air, then with leg elevated and whilst breathing 100 % oxygen. Room-air TCOM values (mean mmHg, 95 % confidence interval (CI) ) were: lateral leg 41.3, CI 37.8 to 44.7; lateral malleolus 38.6, CI 34.1 to 43.1; medial malleolus 43.9, CI 40.2 to 47.6; dorsum, between first and second toe 39.3, CI 35.9 to 42.7; dorsum, proximal to fifth metatarsal-phalangeal joint 46.4, CI 43.4 to 49.3; plantar 52.3, CI 49.6 to 55.1. Using the currently accepted value of less than 40 mmHg for tissue hypoxia, 24 of our 32 'healthy' subjects had at least one air sensor reading that would have been classified as hypoxic. Seventeen subjects had TCOM values less than 100 mmHg when breathing 100 % normobaric oxygen. Normal lower limb TCOM readings using the TCOM400 with tc Sensor E5250 may be lower than 40 mmHg, used to define tissue hypoxia, but consistent with the wide range of values found in the literature. Because of the wide variability in TCOM at the different sensor sites we cannot recommend one TCOM value as indicative of tissue hypoxia. A thorough clinical assessment of the patient is essential to establish appropriateness for hyperbaric oxygen treatment, with TCOM used as an aid to help guide this decision, but not as an absolute diagnostic tool.
Gas and Dust Properties in Dwarf Irregular Galaxies
NASA Technical Reports Server (NTRS)
Jones, A. P.; Madden, S. C.; Colgan, S. W. J.; Geis, N.; Haas, M.; Maloney, P.; Nikola, T.; Poglitsch, A.
1997-01-01
We present a study of the 158 (micron)meter [C II] fine structure emission line from a sample of 11 low metallicity irregular galaxies using the NASA Kuiper Airborne Observatory (KAO). Our preliminary results demonstrate that the ratio of the 158 (micron)meter [C II] emission to the CO-12(1 yields 0) emission ranges from 6,000 to 46,000. These ratios are significantly enhanced relative to clouds within the Galaxy and to normal metallicity galaxies, which typically have values in the range 2,000 to 6,300. We also find that the [C II] emission in dwarf irregular galaxies can be up to 5% of the far-infrared (FIR) emission, a higher fraction of the FIR than in normal metallicity galaxies. We discuss these results for the dwarf irregular galaxies and compare them to those observed in normal metallicity galaxies. The enhanced 158 (micron)meter [C II] emission relative to CO-12(1 yields 0) emission can be understood in terms of the increased penetration depth of ultraviolet (UV) photons into the clouds in low metallicity environments.
Tenascin-C is not a useful marker for disease activity in psoriasis.
Latijnhouwers, M A; Bergers, M; Kuijpers, A L; van der Vleuten, C J; Dijkman, H; van de Kerkhof, P C; Schalkwijk, J
1998-09-01
Tenascin-C is an extracellular matrix glycoprotein that is markedly upregulated in the dermis of psoriatic skin. In this study, we have addressed the question whether the presence of tenascin-C in the lesion or in serum is a marker for disease activity. Immunohistochemical staining of tenascin-C before and after treatment with different topical and systemic medication showed that tenascin-C remained abundant after clinical remission of lesions, indicating that downregulation of tenascin-C to normal values is a slow process. By using a sensitive enzyme-linked immunosorbent assay to measure levels of serum tenascin-C in psoriatic patients and unaffected individuals, we found that tenascin-C levels in most patients were within the normal range. Moreover, tenascin-C values did not correlate with disease activity. We conclude that tenascin-C is not useful as a marker for disease activity in psoriasis.
Optimal False Discovery Rate Control for Dependent Data
Xie, Jichun; Cai, T. Tony; Maris, John; Li, Hongzhe
2013-01-01
This paper considers the problem of optimal false discovery rate control when the test statistics are dependent. An optimal joint oracle procedure, which minimizes the false non-discovery rate subject to a constraint on the false discovery rate is developed. A data-driven marginal plug-in procedure is then proposed to approximate the optimal joint procedure for multivariate normal data. It is shown that the marginal procedure is asymptotically optimal for multivariate normal data with a short-range dependent covariance structure. Numerical results show that the marginal procedure controls false discovery rate and leads to a smaller false non-discovery rate than several commonly used p-value based false discovery rate controlling methods. The procedure is illustrated by an application to a genome-wide association study of neuroblastoma and it identifies a few more genetic variants that are potentially associated with neuroblastoma than several p-value-based false discovery rate controlling procedures. PMID:23378870
Hosoya, Y; Kubota, I; Shibata, T; Yamaki, M; Ikeda, K; Tomoike, H
1992-06-01
There were few studies on the relation between the body surface distribution of high- and low-frequency components within the QRS complex and ventricular tachycardia (VT). Eighty-seven signal-averaged ECGs were obtained from 30 normal subjects (N group) and 30 patients with previous anterior myocardial infarction (MI) with VT (MI-VT[+] group, n = 10) or without VT (MI-VT[-] group, n = 20). The onset and offset of the QRS complex were determined from 87-lead root mean square values computed from the averaged (but not filtered) ECG waveforms. Fast Fourier transform analysis was performed on signal-averaged ECG. The resulting Fourier coefficients were attenuated by use of the transfer function, and then inverse transform was done with five frequency ranges (0-25, 25-40, 40-80, 80-150, and 150-250 Hz). From the QRS onset to the QRS offset, the time integration of the absolute value of reconstructed waveforms was calculated for each of the five frequency ranges. The body surface distributions of these areas were expressed as QRS area maps. The maximal values of QRS area maps were compared among the three groups. In the frequency ranges of 0-25 and 150-250 Hz, there were no significant differences in the maximal values among these three groups. Both MI groups had significantly smaller maximal values of QRS area maps in the frequency ranges of 25-40 and 40-80 Hz compared with the N group. The MI-VT(+) group had significantly smaller maximal values in the frequency ranges of 40-80 and 80-150 Hz than the MI-VT(-) group. These three groups were clearly differentiated by the maximal values of the 40-80-Hz QRS area map. It was suggested that the maximal value of the 40-80-Hz QRS area map was a new marker for VT after anterior MI.
Shukla, Garima; Bhatia, Manvir; Behari, Madhuri
2005-10-01
Small fiber neuropathy is a common neurological disorder, often missed or ignored by physicians, since examination and routine nerve conduction studies are usually normal in this condition. Many methods including quantitative thermal sensory testing are currently being used for early detection of this condition, so as to enable timely investigation and treatment. This study was conducted to assess the yield of quantitative thermal sensory testing in diagnosis of small fiber neuropathy. We included patients presenting with history suggestive of positive and/or negative sensory symptoms, with normal examination findings, clinically suggestive of small fiber neuropathy, with normal or minimally abnormal routine nerve conduction studies. These patients were subjected to quantitative thermal sensory testing using a Medoc TSA-II Neurosensory analyser at two sites and for two modalities. QST data were compared with those in 120 normal healthy controls. Twenty-five patients (16 males, 9 females) with mean age 46.8+/-16.6 years (range: 21-75 years) were included in the study. The mean duration of symptoms was 1.6+/-1.6 years (range: 3 months-6 years). Eighteen patients (72%) had abnormal thresholds in at least one modality. Thermal thresholds were normal in 7 out of the 25 patients. This study demonstrates that quantitative thermal sensory testing is a fairly sensitive method for detection of small fiber neuropathy especially in patients with normal routine nerve conduction studies.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Obrador, D.; Ballester, M.; Carrio, I.
1989-05-01
Monoclonal antimyosin antibody studies were undertaken to assess the presence of myocardial uptake in patients with chronic idiopathic dilated cardiomyopathy. Three groups were studied: 17 patients with chronic (greater than 12 months) idiopathic dilated cardiomyopathy, 12 patients with a large, poorly contracting left ventricle not due to dilated cardiomyopathy (control patients) and 8 normal individuals. The patients in the cardiomyopathy and control groups showed a similar degree of clinical and functional impairment. Imaging was undertaken 48 h after antimyosin injection. The heart/lung ratio of antimyosin uptake was used to assess the results. The mean ratio in the cardiomyopathy group wasmore » 1.83 +/- 0.36 (range 1.40 to 2.80), a value significantly higher than that obtained in the control patients without cardiomyopathy (mean 1.46 +/- 0.04, range 1.38 to 1.50) or normal subjects (mean 1.46 +/- 0.13, range 1.31 to 1.6) (p less than 0.01). No difference in the ratio was noted between the normal subjects and control patients. Abnormal antimyosin uptake was seen in 12 (70%) of the 17 patients with cardiomyopathy and in only 1 (8%) of the 12 control patients. Positive monoclonal antimyosin antibody studies are highly prevalent in chronic idiopathic dilated cardiomyopathy.« less
Eckner, James T; Rettmann, Ashley; Narisetty, Naveen; Greer, Jacob; Moore, Brandon; Brimacombe, Susan; He, Xuming; Broglio, Steven P
2016-01-01
To determine test-re-test reliabilities of novel Evoked Response Potential (ERP)-based Brain Network Activation (BNA) scores in healthy athletes. Observational, repeated-measures study. Forty-two healthy male and female high school and collegiate athletes completed auditory oddball and go/no-go ERP assessments at baseline, 1 week, 6 weeks and 1 year. The BNA algorithm was applied to the ERP data, considering electrode location, frequency band, peak latency and normalized amplitude to generate seven unique BNA scores for each testing session. Mean BNA scores, intra-class correlation coefficient (ICC) values and reliable change (RC) values were calculated for each of the seven BNA networks. BNA scores ranged from 46.3 ± 34.9 to 69.9 ± 22.8, ICC values ranged from 0.46-0.65 and 95% RC values ranged from 38.3-68.1 across the seven networks. The wide range of BNA scores observed in this population of healthy athletes suggests that a single BNA score or set of BNA scores from a single after-injury test session may be difficult to interpret in isolation without knowledge of the athlete's own baseline BNA score(s) and/or the results of serial tests performed at additional time points. The stability of each BNA network should be considered when interpreting test-re-test BNA score changes.
Regional Cerebral Blood Flow In Dementia: Receiver-Operating-Characteristic Analysis
NASA Astrophysics Data System (ADS)
Zemcov, Alexander; Barclay, Laurie; Sansone, Joseph; Blass, John P.; Metz, Charles E.
1985-06-01
The coupling of mentation to regional cerebral blood flow (rCBF) has prompted the application of the Xe-133 inhalation method of measuring rCBF in the differential diagnosis of the two most common dementing diseases, Alzheimer's disease and multi-infarct dementia (MID). In this study receiver-operating-characteristic (ROC) curve analysis was used to assess the effectiveness of a 32 detector Xe-133 inhalation system in discriminating between patients with Alzheimer's disease and normal controls, MID patients and normal controls and between patients with Alzheimer's disease and MID. The populations were clinically evaluated as 1) normal (age 63.1 + 13.1, n=23), 2) Alzheimer's disease (age 72.7 + 7.0, n=82), 3) MID (age 76.4 + 7.6, n=27): The mean flow values for all detectors were lowest for the Alzheimer's disease group, larger for the MID group and largest for the normal controls. The dynamic relationship between the correct identifications (true posi-tives) versus incorrect identifications (false positives) per detector for any 2 pairs of clinical groups varies as the cutoff value of flow is changed over the range of experimental blood flow values. Therefore a quantitative characterization of the "decision" or ROC curve (TP vs FP) for each detector and for each pair of clinical groups provides a measure of the overall diagnostic efficacy of the detector. Detectors directed approximately toward the speech, auditory and association cortices were most effective in disciminatinq between each of the dementia groups and the controls. Frontal detectors were diagnostically inefficient. The Xe-133 inhalation system provided virtually no diagnostic power in discriminating between the two forms of dementia, however. Therefore this imaging technology is most useful when assessing the general diagnostic state of dementia (Alz-heimer's disease and MID) from normal cognitive function.
Hullstein, Ingunn; Sagredo, Carlos; Hemmersbach, Peter
2014-01-01
Determining the origin of anabolic androgenic steroids (AAS) that also are produced endogenously in the human body is a major issue in doping control. In some cases, the presence of nandrolone and boldenone metabolites might result from endogenous production. The GC-C-IRMS technique (gas chromatography-combustion-isotope ratio mass spectrometry) enables the carbon isotopic ratio (CIR) to be measured to determine the origin of these metabolites. The aim of this study was to use GC-C-IRMS to determine the δ(13) CVPDB values of seized boldenone and nandrolone preparations to decide if the steroids themselves were depleted in (13) C, compared to what is normally seen in endogenously produced steroids. In addition, several testosterone preparations were analyzed. A total of 69 seized preparations were analyzed. The nandrolone preparations showed δ(13) CVPDB values in the range of -31.5 ‰ to -26.7 ‰. The boldenone preparations showed δ(13) CVPDB values in the range of -32.0 ‰ to -27.8 ‰, and for comparison the testosterone preparations showed δ(13) CVPDB values of -31.0 ‰ to -24.2 ‰. The results showed that the values measured in the nandrolone and boldenone preparations were in the same range as those measured in the testosterone preparations. The study also included measurements of CIR of endogenously produced steroids in a Norwegian/Danish reference population. The δ(13) CVPDB values measured for the endogenous steroids in this population were in the range of -21.7 to -26.8. In general, most of the preparations investigated in this study show (13) C-depleted delta values compared to endogenously produced steroids reflecting a northern European diet. Copyright © 2014 John Wiley & Sons, Ltd.
Emerging ciliopathies: are respiratory cilia compromised in Usher syndrome?
Piatti, G; De Santi, M M; Brogi, M; Castorina, P; Ambrosetti, U
2014-01-01
Usher syndrome is a ciliopathy involving photoreceptors and cochlear hair cells (sensory cilia): since sensory and motor ciliopathies can overlap, we analysed the respiratory cilia (motile) in 17 patients affected by Usher syndrome and 18 healthy control subject. We studied the mucociliary transport time with the saccharine test, ciliary motility and ultrastructure of respiratory cilia obtained by nasal brushing; we also recorded the classical respiratory function values by spirometry. All enrolled subjects showed normal respiratory function values. The mean mucociliary transport time with saccharine was 22.33 ± 17.96 min, which is in the range of normal values. The mean ciliary beat frequency of all subjects was 8.81 ± 2.18 Hz, which is a value approaching the lower physiological limit. None of the classical ciliary alterations characterizing the "ciliary primary dyskinesia" was detected, although two patients showed alterations in number and arrangement of peripheral microtubules and one patient had abnormal ciliary roots. Respiratory cilia in Usher patients don't seem to have evident ultrastructural alterations, as expected, but the fact that the ciliary motility appeared slightly reduced could emphasize that a rigid distinction between sensory and motor ciliopathies may not reflect what really occurs. Copyright © 2014 Elsevier Inc. All rights reserved.
Effect of carprofen on hemostatic variables in dogs.
Hickford, F H; Barr, S C; Erb, H N
2001-10-01
To evaluate the effect of carprofen on hemostatic variables in clinically normal dogs. 12 clinically normal Labrador Retrievers. 10 dogs (6 females, 4 males) received carprofen (2.2 mg/kg of body weight, PO, q 12 h) for 5 days. Two dogs (untreated control group; 1 female, 1 male) did not receive carprofen. Hemostatic variables (platelet count, activated partial thromboplastin time, prothrombin time, fibrinogen, platelet aggregation, and bleeding time) were assessed for all dogs prior to treatment, on day 5 of treatment, and 2 and 7 days after discontinuation of the drug (days 7 and 12). Serum biochemical variables and Hct were assessed prior to treatment and on days 5 and 12. In dogs receiving carprofen, platelet aggregation was significantly decreased, and onset of aggregation was significantly delayed on days 5, 7, and 12, compared with pretreatment values. Activated partial thromboplastin time was significantly increased on days 5, 7, and 12 over pretreatment values in treated dogs, but values remained within reference ranges. Significant differences were not detected in buccal mucosal bleeding time, other serum biochemical and hemostatic variables, or Hct, compared with pretreatment values and the internal control group. Administration of carprofen for 5 days causes minor but not clinically important alterations in hemostatic and serum biochemical variables in clinically normal Labrador Retrievers. Carprofen is commonly used to treat osteoarthritis and chronic pain in dogs, but prior to this study, its effect on platelet aggregation and hemostatic variables was unknown.
Kusanovic, Juan Pedro; Romero, Roberto; Hassan, Sonia S; Gotsch, Francesca; Edwin, Samuel; Chaiworapongsa, Tinnakorn; Erez, Offer; Mittal, Pooja; Mazaki-Tovi, Shali; Soto, Eleazar; Than, Nandor Gabor; Friel, Lara A; Yoon, Bo Hyun; Espinoza, Jimmy
2007-12-01
Women with preeclampsia and those who deliver small for gestational age (SGA) neonates are characterized by intravascular inflammation (T helper 1 (Th1)-biased immune response). There is controversy about the T helper 2 (Th2) response in preeclampsia and SGA. CD30, a member of the tumor necrosis factor receptor superfamily, is preferentially expressed in vitro and in vivo by activated T cells producing Th2-type cytokines. Its soluble form (sCD30) has been proposed to be an index of Th2 immune response. The objective of this study was to determine whether the maternal serum concentration of sCD30 changes with normal pregnancy, as well as in mothers with preeclampsia and those who deliver SGA neonates. This cross-sectional study included patients in the following groups: (1) non-pregnant women (N = 49); (2) patients with a normal pregnancy (N = 89); (3) patients with preeclampsia (N = 100); and (4) patients who delivered an SGA neonate (N = 78). Maternal serum concentration of sCD30 was measured by a specific and sensitive enzyme-linked immunoassay. Non-parametric tests with post-hoc analysis were used for comparisons. A p value <0.05 was considered statistically significant. (1) The median sCD30 serum concentration of pregnant women was significantly higher than that of non-pregnant women (median 29.7 U/mL, range 12.2-313.2 vs. median 23.2 U/mL, range 14.6-195.1, respectively; p = 0.01). (2) Patients with preeclampsia had a significantly lower median serum concentration of sCD30 than normal pregnant women (median 24.7 U/mL, range 7.6-71.2 vs. median 29.7 U/mL, range 12.2-313.2, respectively; p < 0.05). (3) Mothers with SGA neonates had a lower median concentration of sCD30 than normal pregnant women (median 23.4 U/mL, range 7.1-105.3 vs. median 29.7 U/mL, range 12.2-313.2, respectively; p < 0.05). (4) There was no significant correlation (r = -0.059, p = 0.5) between maternal serum sCD30 concentration and gestational age (19-38 weeks) in normal pregnant women. (1) Patients with preeclampsia and those who deliver an SGA neonate had a significantly lower serum concentration of sCD30 than normal pregnant women. (2) This finding is consistent with the view that preeclampsia and SGA are associated with a polarized Th1 immune response and, perhaps, a reduced Th2 response.
Long-range Cooper pair splitter with high entanglement production rate
Chen, Wei; Shi, D. N.; Xing, D. Y.
2015-01-01
Cooper pairs in the superconductor are a natural source of spin entanglement. The existing proposals of the Cooper pair splitter can only realize a low efficiency of entanglement production, and its size is constrained by the superconducting coherence length. Here we show that a long-range Cooper pair splitter can be implemented in a normal metal-superconductor-normal metal (NSN) junction by driving a supercurrent in the S. The supercurrent results in a band gap modification of the S, which significantly enhances the crossed Andreev reflection (CAR) of the NSN junction and simultaneously quenches its elastic cotunneling. Therefore, a high entanglement production rate close to its saturation value can be achieved by the inverse CAR. Interestingly, in addition to the conventional entangled electron states between opposite energy levels, novel entangled states with equal energy can also be induced in our proposal. PMID:25556521
Sibert, J R; Harper, P S; Thompson, R J; Newcombe, R G
1979-01-01
The mean levels of serum creatinine phosphokinase (CPK) were studied in three groups of women: normal controls (57), obligate carriers for Duchenne muscular dystrophy (30), and mothers of isolated cases of this disease (35). The distribution of the levels in these groups was significantly different and was in keeping with the hypothesis that one-third of isolated cases result from new mutations. The control and carrier ranges overlapped considerably, with the level of CPK of 33% of obligate carriers coming within the 97 1/2 centile of the normal range. Odds against an individual being a carrier were derived for specific mean values of CPK. They should be considered with genetic information using Bayes's theorem. The mean CPK levels in obligate carriers showed significant familial clustering. This may have implications in carrier detection. PMID:485196
Albero, R.; Cerdan, A.; Sanchez Franco, F.
1987-01-01
Hypothyroidism from iodide transport deficiency is a rare disease, especially when found in two affected siblings. Treatment with high doses of iodide has been recommended, but no long term results have been reported. Two siblings with congenital hypothyroidism due to total failure to transport iodide have been followed up during twelve and a half years of treatment with oral potassium iodide. Iodine doses varied between 10.3 and 22 mg/day, and serum total iodine concentrations between 100 and 210 micrograms/dl. Total triiodothyronine (T3), thyroxine (T4) and free T4 were in the normal range during the time of study. Basal thyroid stimulating hormones (TSH) and maximum TSH response to thyrotrophin releasing hormone (TRH) were also in the range of normal values. These data along with clinical findings confirmed the potential usefulness of iodine in hypothyroidism due to complete iodide transport defect. PMID:3451231
Contributions of Microgravity Test Results to the Design of Spacecraft Fire Safety Systems
NASA Technical Reports Server (NTRS)
Friedman, Robert; Urban, David L.
1993-01-01
Experiments conducted in spacecraft and drop towers show that thin-sheet materials have reduced flammability ranges and flame-spread rates under quiescent low-gravity environments (microgravity) as compared to normal gravity. Furthermore, low-gravity flames may be suppressed more easily by atmospheric dilution or decreasing atmospheric total pressure than their normal-gravity counterparts. The addition of a ventilating air flow to the low-gravity flame zone, however, can greatly enhance the flammability range and flame spread. These results, along with observations of flame and smoke characteristics useful for microgravity fire-detection 'signatures', promise to be of considerable value to spacecraft fire-safety designs. The paper summarizes the fire detection and suppression techniques proposed for the Space Station Freedom and discusses both the application of low-gravity combustion knowledge to improve fire protection and the critical needs for further research.
Eitz, Thomas; Schenk, Soren; Fritzsche, Dirk; Bairaktaris, Andreas; Wagner, Otto; Koertke, Heinrich; Koerfer, Reiner
2008-03-01
Although prosthetic valves are durable and easy to implant, the need for lifetime warfarin-based anticoagulation restricts their exclusive usage. We investigated if anticoagulation self-management improves outcome in a single-center series. Between 1994 and 1998, 765 patients with prosthetic valve replacements were prospectively enrolled and randomized to receive conventional anticoagulation management by their primary physician (group 1, n = 295) or to pursue anticoagulation self-management (group 2, n = 470). A study head office was implemented to coordinate and monitor anticoagulation protocols, international normalized ratios (INR), and adverse events. Patients were instructed on how to obtain and test their own blood samples and to adjust warfarin dosages according to the measured INR (target range, 2.5 to 4). Mean INR values were slightly yet significantly smaller in group 1 than in group 2 (2.8 +/- 0.7 vs 3.0 +/- .6, p < 0.001). Moreover, INR values of patients with conventional INR management were frequently measured outside the INR target range, whereas those with anticoagulation self-management mostly remained within the range (35% vs 21%, p < 0.001). In addition, the scatter of INR values was smaller if self-managed. Freedom from thromboembolism at 3, 12, and 24 months, respectively, was 99%, 95%, and 91% in group 1 compared with 99%, 98%, and 96% in group 2 (p = 0.008). Bleeding events were similar in both groups. Time-related multivariate analysis identified INR self-management and higher INR as independent predictors for better outcome. Anticoagulation self-management can improve INR profiles up to 2 years after prosthetic valve replacement and reduce adverse events. Current indications of prosthetic rather than biologic valve implantations may be extended if the benefit of INR self-management is shown by future studies with longer follow-up.
de Bruin, Jeroen S; Adlassnig, Klaus-Peter; Blacky, Alexander; Koller, Walter
2016-05-01
Many electronic infection detection systems employ dichotomous classification methods, classifying patient data as pathological or normal with respect to one or several types of infection. An electronic monitoring and surveillance system for healthcare-associated infections (HAIs) known as Moni-ICU is being operated at the intensive care units (ICUs) of the Vienna General Hospital (VGH) in Austria. Instead of classifying patient data as pathological or normal, Moni-ICU introduces a third borderline class. Patient data classified as borderline with respect to an infection-related clinical concept or HAI surveillance definition signify that the data nearly or partly fulfill the definition for the respective concept or HAI, and are therefore neither fully pathological nor fully normal. Using fuzzy sets and propositional fuzzy rules, we calculated how frequently patient data are classified as normal, borderline, or pathological with respect to infection-related clinical concepts and HAI definitions. In dichotomous classification methods, borderline classification results would be confounded by normal. Therefore, we also assessed whether the constructed fuzzy sets and rules employed by Moni-ICU classified patient data too often or too infrequently as borderline instead of normal. Electronic surveillance data were collected from adult patients (aged 18 years or older) at ten ICUs of the VGH. All adult patients admitted to these ICUs over a two-year period were reviewed. In all 5099 patient stays (4120 patients) comprising 49,394 patient days were evaluated. For classification, a part of Moni-ICU's knowledge base comprising fuzzy sets and rules for ten infection-related clinical concepts and four top-level HAI definitions was employed. Fuzzy sets were used for the classification of concepts directly related to patient data; fuzzy rules were employed for the classification of more abstract clinical concepts, and for top-level HAI surveillance definitions. Data for each clinical concept and HAI definition were classified as either normal, borderline, or pathological. For the assessment of fuzzy sets and rules, we compared how often a borderline value for a fuzzy set or rule would result in a borderline value versus a normal value for its associated HAI definition(s). The statistical significance of these comparisons was expressed in p-values calculated with Fisher's exact test. The results showed that, for clinical concepts represented by fuzzy sets, 1-17% of the data were classified as borderline. The number was substantially higher (20-81%) for fuzzy rules representing more abstract clinical concepts. A small body of data were found to be in the borderline range for the four top-level HAI definitions (0.02-2.35%). Seven of ten fuzzy sets and rules were associated significantly more often with borderline values than with normal values for their respective HAI definition(s) (p<0.001). The study showed that Moni-ICU was effective in classifying patient data as borderline for infection-related concepts and top-level HAI surveillance definitions. Copyright © 2016 Elsevier B.V. All rights reserved.
Biomechanics of a Fixed–Center of Rotation Cervical Intervertebral Disc Prosthesis
Crawford, Neil R.; Baek, Seungwon; Sawa, Anna G.U.; Safavi-Abbasi, Sam; Sonntag, Volker K.H.; Duggal, Neil
2012-01-01
Background Past in vitro experiments studying artificial discs have focused on range of motion. It is also important to understand how artificial discs affect other biomechanical parameters, especially alterations to kinematics. The purpose of this in vitro investigation was to quantify how disc replacement with a ball-and-socket disc arthroplasty device (ProDisc-C; Synthes, West Chester, Pennsylvania) alters biomechanics of the spine relative to the normal condition (positive control) and simulated fusion (negative control). Methods Specimens were tested in multiple planes by use of pure moments under load control and again in displacement control during flexion-extension with a constant 70-N compressive follower load. Optical markers measured 3-dimensional vertebral motion, and a strain gauge array measured C4-5 facet loads. Results Range of motion and lax zone after disc replacement were not significantly different from normal values except during lateral bending, whereas plating significantly reduced motion in all loading modes (P < .002). Plating but not disc replacement shifted the location of the axis of rotation anteriorly relative to the intact condition (P < 0.01). Coupled axial rotation per degree of lateral bending was 25% ± 48% greater than normal after artificial disc replacement (P = .05) but 37% ± 38% less than normal after plating (P = .002). Coupled lateral bending per degree of axial rotation was 37% ± 21% less than normal after disc replacement (P < .001) and 41% ± 36% less than normal after plating (P = .001). Facet loads did not change significantly relative to normal after anterior plating or arthroplasty, except that facet loads were decreased during flexion in both conditions (P < .03). Conclusions In all parameters studied, deviations from normal biomechanics were less substantial after artificial disc placement than after anterior plating. PMID:25694869
Bass, P D; Scanga, J A; Chapman, P L; Smith, G C; Tatum, J D; Belk, K E
2008-07-01
Effects of the dark-cutting condition were examined on commercially slaughtered beef carcass sides that were classified into groups exhibiting 1/3, 1/2, and full degrees of the dark-cutting (DEGDC) condition, as evaluated by a USDA-Agricultural Marketing Service grader (n = 20 per group). Twenty-nine muscles of each carcass side were evaluated to determine the ultimate pH and color (L*, a*, and b*). Fourteen beef muscles (biceps femoris, deep pectoral, chuck complexus, gluteus medius, infraspinatus, latissimus dorsi, psoas major, longissimus thoracis, longissimus lumborum, semimembranosus, semitendinosus, triceps brachii long head, tensor fasciae latae, and vastus lateralis) were evaluated using Warner-Bratzler Shear force (WBSF) and a trained sensory panel. The muscle x DEGDC interaction was significant for ultimate pH, L*, a*, and b* values (P < 0.05). When ultimate pH values of individual muscles were compared with the same muscles evaluated in a previous study, the 1/3, 1/2, and full DEGDC had 7, 9, and 5 muscles, respectively, that fell within a computed 95% prediction limit of what would be considered as a normal pH but were more variable as measured by within-class CV. Color values (L*, a*, and b*) of the muscles from dark-cutting carcasses were numerically lower than those from the normal carcasses. A survey designed to determine the ideal color range of beef lean for retail meat merchandisers (n = 34) and food service chefs (n = 33) across the United States resulted in data analyzed using principal components analysis of L*, a*, and b* values for muscles dissected in the study to estimate the true values for dark-cutting carcasses. Muscles that were within an acceptable color value range for food service chefs had the potential to add between $42.29 to $26.44 and $14.71 to $8.11 per side when valued at Choice and Select prices, respectively. Muscles that were within an acceptable color value range had the potential to add between $30.39 to $16.74 and $10.37 to $5.03 per side for retail meat merchandisers when acceptable muscles were valued at Choice and Select prices, respectively. No muscle x DEGDC interactions were detected for WBSF and sensory panel scores (P > 0.05), but differences were detected among muscles (P < 0.05). Several muscles were considered salvageable from the dark-cutting carcasses that were evaluated, and no significant differences in sensory scores or WBSF between DEGDC classes suggested equal sensory expectations for muscles from dark-cutting carcasses.
Metrication of clinical laboratory data in SI units.
Lehmann, H P
1976-01-01
The development and general concepts of the Système International d'Unités (SI units) are discussed. The basic and derived quantities and units of the SI used for clinical laboratory data are reviewed. Ranges of normal values for a number of body fluid constituents are given in the units in current general use and in SI units, with corresponding conversion factors.
Kim, Beom Kyung; Kim, Seung Up; Choi, Gi Hong; Han, Woong Kyu; Park, Mi Sung; Kim, Eun Hye; Park, Jun Yong; Kim, Do Young; Choi, Jin Sub; Yang, Seung Choul; Choi, Eun Hee; Song, Kijun; Ahn, Sang Hoon; Han, Kwang-Hyub; Chon, Chae Yoon
2012-04-01
Liver stiffness (LS) measurement can distinguish individuals with potential liver disease (LD) from the general population. However, if LS is sex-sensitive, prevalence of LD may be incorrectly estimated when the same reference LS value is applied irrespective of sex. Here, we evaluated whether normal ranges of LS differ between healthy men and women. LS was measured in a cohort of healthy living liver and kidney donors, none of whom suffered from diabetes mellitus, hypertension, hepatitis B or C virus infection, heart or liver dysfunction, or metabolic syndrome. Patients with abnormal laboratory findings related to potential LD (platelet count < 150 × 10(3) /µL; aspartate aminotransferase > 40 IU/L; alanine aminotransferase [ALT] > 40 IU/L; albumin < 3.3 g/dL; total bilirubin > 1.2 mg/dL; gamma-glutamyl transpeptidase > 54 IU/L; alkaline phosphatase > 115 IU/L) were excluded. Among 242 patients analyzed, the mean age was 34.1 for men (n = 121) and 40.5 years for women (n = 121) (P < 0.001). Men had a higher mean LS value than women (5.2 ± 1.2 vs 4.8 ± 1.1 kPa/P < 0.001). Multivariate-linear regression analysis identified sex as the only independent factor for LS values (β = 0.361/P = 0.021). Using the 5th-95th percentiles, we determined normal LS ranges of 3.7-7.0 kPa in men and 3.3-6.8 kPa in women. In subgroups with ALT < 30 IU/L (subgroup-1, n = 216) and ALT < 20 IU/L (subgroup-2, n = 163), men had significantly higher LS values than women (5.2 ± 1.3 vs 4.7 ± 1.1 kPa/P = 0.003 and 5.1 ± 1.2 vs 4.7 ± 1.1 kPa/P = 0.030, respectively), demonstrating an independent sex effect (β = 0.483/P = 0.003 and β = 0.389/P = 0.030, respectively). An independent sex effect on LS values was confirmed. Thus, sex-specific references should be used for effective screening based on LS measurements. © 2011 Journal of Gastroenterology and Hepatology Foundation and Blackwell Publishing Asia Pty Ltd.
Probabilistic analysis of preload in the abutment screw of a dental implant complex.
Guda, Teja; Ross, Thomas A; Lang, Lisa A; Millwater, Harry R
2008-09-01
Screw loosening is a problem for a percentage of implants. A probabilistic analysis to determine the cumulative probability distribution of the preload, the probability of obtaining an optimal preload, and the probabilistic sensitivities identifying important variables is lacking. The purpose of this study was to examine the inherent variability of material properties, surface interactions, and applied torque in an implant system to determine the probability of obtaining desired preload values and to identify the significant variables that affect the preload. Using software programs, an abutment screw was subjected to a tightening torque and the preload was determined from finite element (FE) analysis. The FE model was integrated with probabilistic analysis software. Two probabilistic analysis methods (advanced mean value and Monte Carlo sampling) were applied to determine the cumulative distribution function (CDF) of preload. The coefficient of friction, elastic moduli, Poisson's ratios, and applied torque were modeled as random variables and defined by probability distributions. Separate probability distributions were determined for the coefficient of friction in well-lubricated and dry environments. The probabilistic analyses were performed and the cumulative distribution of preload was determined for each environment. A distinct difference was seen between the preload probability distributions generated in a dry environment (normal distribution, mean (SD): 347 (61.9) N) compared to a well-lubricated environment (normal distribution, mean (SD): 616 (92.2) N). The probability of obtaining a preload value within the target range was approximately 54% for the well-lubricated environment and only 0.02% for the dry environment. The preload is predominately affected by the applied torque and coefficient of friction between the screw threads and implant bore at lower and middle values of the preload CDF, and by the applied torque and the elastic modulus of the abutment screw at high values of the preload CDF. Lubrication at the threaded surfaces between the abutment screw and implant bore affects the preload developed in the implant complex. For the well-lubricated surfaces, only approximately 50% of implants will have preload values within the generally accepted range. This probability can be improved by applying a higher torque than normally recommended or a more closely controlled torque than typically achieved. It is also suggested that materials with higher elastic moduli be used in the manufacture of the abutment screw to achieve a higher preload.
Hereditary deficiency of the sixth component of complement in man. II. Studies of hemostasis.
Heusinkveld, R S; Leddy, J P; Klemperer, M R; Breckenridge, R T
1974-01-01
Prompted by previous observations of defective blood clotting in rabbits deficient in the sixth component of complement (C6), an evaluation was made of the hemostatic functions of the homozygous proband of a newly recognized human kindred with hereditary C6 deficiency. This human subject, who had no clinical evidence of a bleeding disorder, exhibited a total lack of C6 by functional and immunoprecipitin assays of serum or plasma. Standard tests of hemostatic function were normal; however, when the whole blood clotting time was measured at 25 degrees C in plastic tubes, it was at the upper range of our normal values. In confirmation of this observation, prothrombin consumption, when performed at 37 degrees C in plastic tubes, was at the lower range of normal. Inulin and endotoxin, in concentrations shown to cause activation of human complement, had little or no effect on clotting times or prothrombin consumption of normal or C6-deficient human blood. These observations indicate that absence of C6 does not have a significant effect on hemostatic function in man. In the light of other investigations, the observed differences in clotting function between C6-deficient human blood and C6-deficient rabbit blood could be due to species differences governing the susceptibility of platelets to complement activation. PMID:11344569
Visual and binocular status in elementary school children with a reading problem.
Christian, Lisa W; Nandakumar, Krithika; Hrynchak, Patricia K; Irving, Elizabeth L
2017-11-21
This descriptive study provides a summary of the binocular anomalies seen in elementary school children identified with reading problems. A retrospective chart review of all children identified with reading problems and seen by the University of Waterloo, Optometry Clinic, from September 2012 to June 2013. Files of 121 children (mean age 8.6 years, range 6-14 years) were reviewed. No significant refractive error was found in 81% of children. Five and 8 children were identified as strabismic at distance and near respectively. Phoria test revealed 90% and 65% of patients had normal distance and near phoria. Near point of convergencia (NPC) was <5cm in 68% of children, and 77% had stereoacuity of ≤40seconds of arc. More than 50% of the children had normal fusional vergence ranges except for near positive fusional vergencce (base out) break (46%). Tests for accommodation showed 91% of children were normal for binocular facility, and approximately 70% of children had an expected accuracy of accommodation. Findings indicate that some children with an identified reading problem also present with abnormal binocular test results compared to published normal values. Further investigation should be performed to investigate the relationship between binocular vision function and reading performance. Crown Copyright © 2017. Published by Elsevier España, S.L.U. All rights reserved.
Niebisch, S; Wilshire, C L; Peters, J H
2013-01-01
The introduction of high-resolution manometry (HRM) has been a significant advance in esophageal diagnostics. Normative values however are currently based upon a single set of published reference values, and multiple new metrics have been added over the past several years. Our goal was to provide a second set of 'normal-values' and to include all current metrics suggested by the 2012 Chicago classification. Sixty-eight subjects without foregut symptoms or previous surgery (median age 25.5 years, ranging from 20-58 years, 53% female) underwent esophageal motility assessment via an established standardized protocol. Normative thresholds were calculated for esophago-gastric junction (EGJ) characteristics (resting, relaxation, intrabolus pressure, and lengths) as well as for esophageal body strength (contraction amplitudes at multiple levels, distal contractile integral, integrity of peristalsis) and wave propagation (contractile front velocity, distal latency). Overall, our findings where strikingly similar to the previously described metrics derived from 75 control subjects of the Northwestern group. This suggests a high degree of reproducibility of HRM. © 2013 Wiley Periodicals, Inc. and the International Society for Diseases of the Esophagus.
Kuehni, Claudia E; Schindler, Matthias; Mazur, Agnieszka; Malzacher, Andreas; Hornung, René; Barben, Juerg
2017-07-01
Nanoduct™ is a simple and practical sweat analysis system measuring conductivity in situ. It requires only three microlitres of sweat, making it especially applicable to newborns. We measured conductivity in 260 healthy term infants at the age of four days, and again at four weeks to determine the proportion of successful tests, test duration, and normal values for sweat conductivity in newborns. Sufficient sweat was collected in 159/260 of four-day olds (61%), and in 225/239 of four-week olds (94%). Mean (sd) test duration was 27 (5) and 25 (5) min. Mean (sd, range) conductivity was 53mmol/l (16, 8-114) at age four days, and 36 (9, 12-64) at four weeks. Determination of sweat conductivity using Nanoduct™ cannot be recommended for four-day old newborns. However, at the age of four weeks the success rate is high (94%), and conductivity values at that age are comparable to older healthy children. Copyright © 2017 European Cystic Fibrosis Society. Published by Elsevier B.V. All rights reserved.
Three-in-one weight, height and body mass index charts for children and adults.
Elizabeth, K E; Muraleedharan, Manu
2003-08-01
The aim of the study was to develop four appropriate three-in-one weight, height and built in body mass index (BMI) charts, for under-fives, 0-5-year-olds, > 5-10-year-olds, > 10-18-year-olds, and adults and to delineate the normal range, underweight, overweight and obesity on the above charts. Four different charts were designed for the various age groups as indicated above. Height was made available on the x-axis, weight on the y-axis, and corresponding BMI values on the right margin. Shading of the normal range to denote the health path and marking of the cut-off curves to denote normal status, overweight, and obesity were done selecting appropriate round figures to suit both sexes in accordance with the International Obesity Task Force (IOTF) recommendations for the various age groups. Field trials were done on appropriate subjects belonging to various age groups. 500 in each group with equal male to female ratio. The field trials showed that all the studied subjects belonging to both sexes came within the purview of the chart and those with normal nutritional status, underweight, overweight, and obesity could easily be identified looking at the chart without doing any further calculation. Early intervention also could be advised as the chart could demonstrate how much weight should be gained or reduced to come within the health path. In conclusion, the charts are applicable to both sexes and are user friendly. These are appropriate for general screening of nutritional status and to determine underweight, overweight, and obesity from birth to adulthood. They give a visual display of the ideal health path with respect to weight, height, and BMI and the adjustment in weight required to reach the normal range.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ma Lijun, E-mail: lijunma@radonc.ucsf.ed; Sahgal, Arjun; Descovich, Martina
2010-03-01
Purpose: To investigate whether dose fall-off characteristics would be significantly different among intracranial radiosurgery modalities and the influence of these characteristics on fractionation schemes in terms of normal tissue sparing. Methods and Materials: An analytic model was developed to measure dose fall-off characteristics near the target independent of treatment modalities. Variations in the peripheral dose fall-off characteristics were then examined and compared for intracranial tumors treated with Gamma Knife, Cyberknife, or Novalis LINAC-based system. Equivalent uniform biologic effective dose (EUBED) for the normal brain tissue was calculated. Functional dependence of the normal brain EUBED on varying numbers of fractions (1more » to 30) was studied for the three modalities. Results: The derived model fitted remarkably well for all the cases (R{sup 2} > 0.99). No statistically significant differences in the dose fall-off relationships were found between the three modalities. Based on the extent of variations in the dose fall-off curves, normal brain EUBED was found to decrease with increasing number of fractions for the targets, with alpha/beta ranging from 10 to 20. This decrease was most pronounced for hypofractionated treatments with fewer than 10 fractions. Additionally, EUBED was found to increase slightly with increasing number of fractions for targets with alpha/beta ranging from 2 to 5. Conclusion: Nearly identical dose fall-off characteristics were found for the Gamma Knife, Cyberknife, and Novalis systems. Based on EUBED calculations, normal brain sparing was found to favor hypofractionated treatments for fast-growing tumors with alpha/beta ranging from 10 to 20 and single fraction treatment for abnormal tissues with low alpha/beta values such as alpha/beta = 2.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Turner, Adam C.; Zankl, Maria; DeMarco, John J.
2010-04-15
Purpose: Monte Carlo radiation transport techniques have made it possible to accurately estimate the radiation dose to radiosensitive organs in patient models from scans performed with modern multidetector row computed tomography (MDCT) scanners. However, there is considerable variation in organ doses across scanners, even when similar acquisition conditions are used. The purpose of this study was to investigate the feasibility of a technique to estimate organ doses that would be scanner independent. This was accomplished by assessing the ability of CTDI{sub vol} measurements to account for differences in MDCT scanners that lead to organ dose differences. Methods: Monte Carlo simulationsmore » of 64-slice MDCT scanners from each of the four major manufacturers were performed. An adult female patient model from the GSF family of voxelized phantoms was used in which all ICRP Publication 103 radiosensitive organs were identified. A 120 kVp, full-body helical scan with a pitch of 1 was simulated for each scanner using similar scan protocols across scanners. From each simulated scan, the radiation dose to each organ was obtained on a per mA s basis (mGy/mA s). In addition, CTDI{sub vol} values were obtained from each scanner for the selected scan parameters. Then, to demonstrate the feasibility of generating organ dose estimates from scanner-independent coefficients, the simulated organ dose values resulting from each scanner were normalized by the CTDI{sub vol} value for those acquisition conditions. Results: CTDI{sub vol} values across scanners showed considerable variation as the coefficient of variation (CoV) across scanners was 34.1%. The simulated patient scans also demonstrated considerable differences in organ dose values, which varied by up to a factor of approximately 2 between some of the scanners. The CoV across scanners for the simulated organ doses ranged from 26.7% (for the adrenals) to 37.7% (for the thyroid), with a mean CoV of 31.5% across all organs. However, when organ doses are normalized by CTDI{sub vol} values, the differences across scanners become very small. For the CTDI{sub vol}, normalized dose values the CoVs across scanners for different organs ranged from a minimum of 2.4% (for skin tissue) to a maximum of 8.5% (for the adrenals) with a mean of 5.2%. Conclusions: This work has revealed that there is considerable variation among modern MDCT scanners in both CTDI{sub vol} and organ dose values. Because these variations are similar, CTDI{sub vol} can be used as a normalization factor with excellent results. This demonstrates the feasibility of establishing scanner-independent organ dose estimates by using CTDI{sub vol} to account for the differences between scanners.« less
Versmold, H T; Linderkamp, C; Döhlemann, C; Riegel, K P
1976-06-01
In 48 individuals (age 1 day to 13 years) with congenital heart disease, blood oxygen transport function was studied in order to evaluate adaptive changes in shunt hypoxemia and to investigate the in vivo regulation of erythrocyte 2, 3-diphosphoglycerate concentration (RBC 2, 3-DPG) in the presence of fetal hemoglobin (HbF). Arterial pO2 and oxygen content, oxygen capacity, acid base status, oxygen affinity, HbF fraction, plasma pH, red cell pH, and RBC 2, 3-DPG were determined. During the first 50 days of life values of standard P50 (stdP50) (37, pH 7.4), actual in vivo P50 (actP50), RBC 2, 3-DPG, O2 capacity, arterial plasma pH, and red cell pH were scattered around the normal range, although tending to low values for stdP50 and arterial plasma pH and to high values for O2 capacity. After the third month, stdP50 actP50, RBC 2, 3-DPG, O2 capacity, and red cell pH were found to be elevated. Plasma pH and actP50 were scattered around the normal range (Figs. 1 and 2). Intraerythrocytic pH in hypoxemic infants was increased compared with normal children when related to plasma pH (Fig. 3). A close to normal intraerythrocytic pH was therefore found in the hypoxemic infants with low plasma pH, and an increased intraerythrocytic pH in the hypoxemic children with normal plasma pH (Fig. 1). A significant negative correlation exists between erythrocyte H+ ion and 2, 3-DPG concentration (Fig. 5); regression constants derived from data at high (mean 47%) and low (mean 9%) fractions of HbF are not significantly different (Regression Equations 8 and 11 in Table 1). Thus, the known difference in 2, 3-DPG binding to fetal or adult deoxyhemoglobin does not measurably influence the erythrocyte 2, 3-DPG concentration, indicating that in vivo the 2, 3-DPG synthesis in hypoxia is virtually regulated by the erythrocyte pH, which in turn is determined by plasma pH and the oxygenation state of hemoglobin.
Determining successional stage of temperate coniferous forests with Landsat satellite data
NASA Technical Reports Server (NTRS)
Fiorella, Maria; Ripple, William J.
1993-01-01
Thematic Mapper (TM) digital imagery was used to map forest successional stages and to evaluate spectral differences between old-growth and mature forests in the central Cascade Range of Oregon. Relative sun incidence values were incorporated into the successional stage classification to compensate for topographic induced variation. Relative sun incidence improved the classification accuracy of young successional stages, but did not improve the classification accuracy of older, closed canopy forest classes or overall accuracy. TM bands 1, 2, and 4; the normalized difference vegetation index; and TM 4/3, 4/5, and 4/7 band ratio values for o|d-growth forests were found to be significantly lower than the values of mature forests. The Tasseled Cap features of brightness, greenness, and wetness also had significantly lower old-growth values as compared to mature forest values .
Ghanbari, Cheryl M; Ho, Clifford K; Kolb, Gregory J
2014-03-04
Various technologies described herein pertain to evaluating a beam reflected by a heliostat. A portable target that has an array of sensors mounted thereupon is configured to capture the beam reflected by the heliostat. The sensors in the array output measured values indicative of a characteristic of the beam reflected by the heliostat. Moreover, a computing device can generate and output data corresponding to the beam reflected by the heliostat based on the measured values indicative of the characteristic of the beam received from the sensors in the array.
Grüsser-Cornehls, U
1995-01-01
The responses of vestibular nuclei (Vn) neurons and floccular Purkinje (P) cells to natural stimulation of the horizontal canals were recorded in paralyzed Weaver mutant mice. The Weaver mice suffer from an almost complete postnatal degeneration of granule cells and a portion of the P cells (Sidman et al. 1965). Parallel fibers are never elaborated (Bradley and Berry 1978). Recording sites were localized by means of small, iontophoretically applied HRP markings. Phase and sensitivity were analyzed by a Fourier analysis and a "best sine fitting" program. As in the normal "control" mice (Grüsser-Cornehls et al. 1995), the "simple spike" discharges of Vn and P cells in Weaver mutant mice are modulated sinusoidally upon sinusoidal stimulation. The neuronal response amplitude at fundamental frequency (determined from peristimulus time histograms, PSTHs increased with frequency (0.05-0.5 Hz) for both Vn and floccular neurons. The stimulus frequency/response amplitude and sensitivity (re velocity) curves for floccular neurons are distinctly lower in magnitude than those of Vn neurons (P < 0.01). In our sample of neurons, the Vn neurons curves of the mutants display a remarkable be behavior: the mean value curve of type I neurons is shifted upward, indicating a loss of inhibition but that of type II, downward, demonstrating a downregulation in comparison with the control values. The difference between the two curves is statistically significant (P < 0.001). The mean value curve of all mutant Vn neurons depends on the different fractions of type I and type II neurons in the sample investigated. In our investigations, the mean value curves of both type I and type II neurons also exceed those of the normal controls. The phase shift relative to head angular velocity in the midfrequency range in Vn neurons was very similar to that in normal controls, but the phase advance in the range of 0.3-0.5 Hz was somewhat larger and the SD larger over the whole range tested. Concerning the phase relationship for floccular neurons, a major difference occurred in contrast to the normal controls: the phase lead and phase lag varied from neurons to neuron, in individual neurons from frequency to frequency, and in some neurons distinctly from trial to trail. It is hypothesized that an intact mossy fiber-granule cell-parallel fiber system plays an important role in an orderly information flow, transmitted through the P-cell axons, and that the morphological disruption has implications for target cell activity. There is a strong suggestion that the diverse behavior of type I and type II neurons in the Vn may have implications for the poor motor performance in Weaver mutant mice.
Lu, Ying-Chun; Wang, Chih-Chien; Lee, Chuen-Ming; Hwang, Kwei-Shuai; Hua, Yi-Ming; Yuh, Yeong-Seng; Chiu, Yu-Lung; Hsu, Wan-Fu; Chou, Ya-Ling; Huang, Shao-Wei; Lee, Yih-Jing; Fan, Hueng-Chuen
2014-12-01
We compared our clinical experience with currently available reference oxygen saturation level (SpO(2)) values from the American Academy of Pediatrics/American Heart Association (AAP/AHA) neonatal resuscitation program guidelines. We enrolled 145 healthy full-term neonates; infants showing respiratory distress and those with serious congenital anomalies were excluded. SpO(2) values at every 1 minute until 10 minutes after birth were measured and recorded. Infants were classified into the cesarean section (CS) and normal spontaneous delivery (NSD) groups for evaluating differences. The 10(th) percentiles of SpO(2) at each minute were used as the lower limits of normal oxygen saturation, and these were compared with the lowest target values recommended in the AAP/AHA guidelines. Overall, 130 vigorous full-term neonates (median gestational age: 38 5/7 weeks; body weight at birth: 2405-3960 g) were analyzed. The median SpO(2) were 67% and 89% at the 1(st) and 4(th) minute, respectively. On average, SpO(2) values reached >90% at the 5(th) minute. No statistical differences were noted in the SpO(2) values between the CS and NSD groups after 5 minutes; however, a trend of higher SpO(2) was observed in the NSD group. We noted a gradually increasing trend for SpO(2) values over time, similar to that noted in the AAP/AHA guidelines. However, SpO(2) values at the 10(th) percentiles of each minute within the first 5 minutes in our study were equal to or significantly lower than those in the AAP/AHA guidelines; moreover, at the 10(th) minute, SpO(2) values at the 10(th) percentiles were significantly higher than those in the guidelines. The delivery modes did not affect the SpO(2) values of full-term healthy neonates. Discrepancies in SpO(2) changes in full-term neonates not requiring resuscitation between this study and the AAP/AHA guidelines were significant. SpO(2) ranges for each time point within the first 10 minutes after birth should therefore be reevaluated locally. Copyright © 2014. Published by Elsevier B.V.
Shi, Jingsheng; Chen, Jie; Wu, Jianguo; Chen, Feiyan; Huang, Gangyong; Wang, Zhan; Zhao, Guanglei; Wei, Yibing; Wang, Siqun
2014-01-01
Background The aim of this study was to contrast the collapse values of the postoperative weight-bearing areas of different tantalum rod implant positions, fibula implantation, and core decompression model and to investigate the advantages and disadvantages of tantalum rod implantation in different ranges of osteonecrosis in comparison with other methods. Material/Methods The 3D finite element method was used to establish the 3D finite element model of normal upper femur, 3D finite element model after tantalum rod implantation into different positions of the upper femur in different osteonecrosis ranges, and other 3D finite element models for simulating fibula implant and core decompression. Results The collapse values in the weight-bearing area of the femoral head of the tantalum rod implant model inside the osteonecrosis area, implant model in the middle of the osteonecrosis area, fibula implant model, and shortening implant model exhibited no statistically significant differences (p>0.05) when the osteonecrosis range was small (60°). The stress values on the artificial bone surface for the tantalum rod implant model inside the osteonecrosis area and the shortening implant model exhibited statistical significance (p<0.01). Conclusions Tantalum rod implantation into the osteonecrosis area can reduce the collapse values in the weight-bearing area when osteonecrosis of the femoral head (ONFH) was in a certain range, thereby obtaining better clinical effects. When ONFH was in a large range (120°), the tantalum rod implantation inside the osteonecrosis area, shortening implant or fibula implant can reduce the collapse values of the femoral head, as assessed by other methods. PMID:25479830
Poncelet, L C; Coppens, A G; Meuris, S I; Deltenre, P F
2000-11-01
To evaluate auditory maturation in puppies. Ten clinically normal Beagle puppies. Puppies were examined repeatedly from days 11 to 36 after birth (8 measurements). Click-evoked brain stem auditory-evoked potentials (BAEP) were obtained in response to rarefaction and condensation click stimuli from 90 dB normal hearing level to wave V threshold, using steps of 10 dB. Responses were added, providing an equivalent to alternate polarity clicks, and subtracted, providing the rarefaction-condensation differential potential (RCDP). Steps of 5 dB were used to determine thresholds of RCDP and wave V. Slope of the low-intensity segment of the wave V latency-intensity curve was calculated. The intensity range at which RCDP could not be recorded (ie, pre-RCDP range) was calculated by subtracting the threshold of wave V from threshold of RCDP RESULTS: Slope of the wave V latency-intensity curve low-intensity segment evolved with age, changing from (mean +/- SD) -90.8 +/- 41.6 to -27.8 +/- 4.1 micros/dB. Similar results were obtained from days 23 through 36. The pre-RCDP range diminished as puppies became older, decreasing from 40.0 +/- 7.5 to 20.5 +/- 6.4 dB. Changes in slope of the latency-intensity curve with age suggest enlargement of the audible range of frequencies toward high frequencies up to the third week after birth. Decrease in the pre-RCDP range may indicate an increase of the audible range of frequencies toward low frequencies. Age-related reference values will assist clinicians in detecting hearing loss in puppies.
Evaluation of pH of Bathing Soaps and Shampoos for Skin and Hair Care.
Tarun, Jose; Susan, Jose; Suria, Jacob; Susan, Veronica John; Criton, Sebastian
2014-09-01
Normal healthy skin has potential of hydrogen (pH) range of 5.4-5.9 and a normal bacterial flora. Use of soap with high pH causes an increase in skin pH, which in turn causes an increase in dehydrative effect, irritability and alteration in bacterial flora. The majority of soaps and shampoos available in the market do not disclose their pH. The aim of this study was to assess the pH of different brands of bathing soaps and shampoos available in the market. The samples of soaps and shampoos were collected from shops in the locality. The samples of different brands are coded before the analysis of the pH. Solution of each sample was made and pH was measured using pH meter. Majority of the soaps have a pH within the range of 9-10. Majority of the shampoos have a pH within the range of 6-7. The soaps and shampoos commonly used by the population at large have a pH outside the range of normal skin and hair pH values. Therefore, it is hoped that before recommending soap to patient especially those who have sensitive and acne prone skin, due consideration is given to the pH factor and also that manufacturers will give a thought to pH of soaps and shampoos manufactured by them, so that their products will be more skin and hair friendly.
Monkos, Karol
2013-03-01
The paper presents the results of viscosity determinations on aqueous solutions of human serum albumin (HSA) at isoelectric point over a wide range of concentrations and at temperatures ranging from 5°C to 45°C. On the basis of a modified Arrhenius equation and Mooney's formula some hydrodynamic parameters were obtained. They are compared with those previously obtained for HSA in solutions at neutral pH. The activation energy and entropy of viscous flow and the intrinsic viscosity reach a maximum value, and the effective specific volume, the self-crowding factor and the Huggins coefficient a minimum value in solutions at isoelectric point. Using the dimensionless parameter [η]c, the existence of three ranges of concentrations: diluted, semi-diluted and concentrated, was shown. By applying Lefebvre's relation for the relative viscosity in the semi-dilute regime, the Mark-Houvink-Kuhn-Sakurada (MHKS) exponent was established. The analysis of the results obtained from the three ranges of concentrations showed that both conformation and stiffness of HSA molecules in solutions at isoelectric point and at neutral pH are the same.
Design flow duration curves for environmental flows estimation in Damodar River Basin, India
NASA Astrophysics Data System (ADS)
Verma, Ravindra Kumar; Murthy, Shankar; Verma, Sangeeta; Mishra, Surendra Kumar
2017-06-01
In this study, environmental flows (EFs) are estimated for six watersheds of Damodar River Basin (DRB) using flow duration curve (FDC) derived using two approaches: (a) period of record and (b) stochastic approaches for daily, 7-, 30-, 60-day moving averages, and 7-daily mean annual flows observed at Tenughat dam, Konar dam, Maithon dam, Panchet dam, Damodar bridge, Burnpur during 1981-2010 and at Phusro during 1988-2010. For stochastic FDCs, 7-day FDCs for 10, 20-, 50- and 100-year return periods were derived for extraction of discharge values at every 5% probability of exceedance. FDCs derived using the first approach show high probability of exceedance (5-75%) for the same discharge values. Furthermore, discharge values of 60-day mean are higher than those derived using daily, 7-, and 30-day mean values. The discharge values of 95% probability of exceedance (Q95) derived from 7Q10 (ranges from 2.04 to 5.56 cumec) and 7Q100 (ranges from 3.4 to 31.48 cumec) FDCs using the second approach are found more appropriate as EFs during drought/low flow and normal precipitation years.
Serum antioxidant status in patients with systemic sclerosis.
Hassan, Iffat; Sajad, Peerzada; Majid, Sabiya; Hassan, Tehseen
2013-05-01
Vascular endothelial dysfunction is a central event in pathogenesis of a variety of human diseases. Systemic sclerosis is one of such diseases. The oxidative stress and depletion of antioxidants in the serum is believed to be one of the factors in causing this dysfunction. The aim of this case control study was to compare the levels of antioxidants in the serum of patients with systemic sclerosis and the normal age and sex matched controls. Our study consisted of 16 successively admitted patients with systemic sclerosis and 16 healthy, age and sex matched controls. The age group of patient's ranged between 25 and 55 years. The duration of the disease in patients ranged from 1 to 8 years. The serum of patients and controls were assayed for the levels of antioxidants (GSH, NO, MDA, SOD and GPX) by spectrophotometry. The statistical method of analysis used was the one sample t-test. THE MEDIAN LEVELS OF ANTIOXIDANTS IN THE CONTROL PATIENTS WERE: SOD-4.14 units/ml; GSH-4.76 units/ml; NO-5.58 nmol/l; MDA-0.53 nmol/l and GPX-49 μmol/l. The levels of NO, GSH and SOD were decreased in these patients with a significant P value (<0.001) whereas the levels of GPX and MDA were normal to increased with a significant P value. The depletion of antioxidants and oxidative stress in serum might be responsible for the vascular dysfunction and other hallmark manifestations of systemic sclerosis. Therefore micronutrient antioxidant supplements may be of therapeutic value.
Taieb, Joëlle; Mendez Lozano, Daniel H; Benattar, Clarisse; Messaoudi, Chérif; Poüs, Christian
2007-12-01
We assessed a new estradiol (E2) immunoassay on the Architect-i2000 (Abbott Laboratories) for monitoring ovulation stimulation for IVF-ET and re-establishing clinical cut-off points. The method has been modified to improve E2 measurements especially at normal and low concentrations. E2 was determined for 552 samples, from 83 women, presenting normal follicular status and undergoing 100 cycles of IVF treatment. We assessed the value of this assay for down-regulation of E2 concentration limit using gonadoliberin-releasing hormone agonist (GnRHa), and monitoring of the ovarian hyperstimulation, expected range of E2 per mature follicle prior to the administration of exogenous hCG and day 3 concentration limit. We compared results with our routine method (E2-6II Advia-Centaur; Siemens-Diagnostics) for which decision-making values were known. Considering E2 concentrations obtained with the new Architect-i2000 assay for patients treated with GnRHa for 2 weeks, the cutoff-point for ovarian down-regulation should be set down at 110 pmol/L to maintain 100% of sensitivity. Considering day 3 concentration limit determination, results were not significantly different from those obtained with our routine method. The mean E2 values per mature follicle fell into the range generally expected. E2 determination with the new E2 Architect-i2000 assay could be used to monitor ovulation, in patients undergoing IVF-ET, in combination with transvaginal ultrasound.
Mathew, George; Kho, Abel; Dexter, Paul; Bloodworth, Nathaniel; Fantz, Corinne; Spell, Nathan; LaBorde, David V
2012-06-01
To develop a clinical decision support system activated at the time of discharge to reduce potentially inappropriate discharges from unidentified or unaddressed abnormal laboratory values. We identified 106 laboratory tests for possible inclusion in the discharge alert filter. We selected 7 labs as widely available, commonly obtained, and associated with high risk for potential morbidity or mortality within abnormal ranges. We identified trigger thresholds at levels that would capture significant laboratory abnormalities while avoiding excessive flag generation because of laboratory results that minimally deviate outside the normal reference range. We selected sodium (>155 or <125 mmol/L), potassium (<2.5 or >6 mEq/dL) phosphorous (<1.6 mg/dL), magnesium (<1.2 mg/dL), creatinine greater than 1.1 with a rise of 20% or more between the 2 most recent results, white blood cell count (>11,000 cells/mm with a rise of 20% or more between the 2 most recent results), and international normalized ratio greater than 4. A discharge alert filter that reliably and effectively identifies patients that may be discharged in unsafe situations because of unaddressed critical laboratory values can improve patient safety at discharge and potentially reduce the incidence of costly litigation. Further research is needed to validate whether the proposed discharge alert filter is effective at improving patient safety at discharge.
NASA Astrophysics Data System (ADS)
Proctor, B.; Mitchell, T. M.; Hirth, G.; Goldsby, D. L.; Di Toro, G.; Zorzi, F.
2013-12-01
High-velocity friction (HVF) experiments on bare rock surfaces have revealed various dynamic weakening processes (e.g., flash weakening, gel weakening, melt lubrication) that likely play a fundamental role in coseismic fault weakening. However, faults generally contain a thin layer of gouge separating the solid wallrocks, thus it is important to understand how the presence of gouge modifies the efficiency of these weakening processes at seismic slip rates. We explored the frictional behavior of bare surfaces and powdered samples of an antigorite-rich serpentinite (ARS) and a lizardite-rich serpentinite (LRS) at earthquake slip rates. HVF experiments were conducted with slip displacements ranging from ~0.5 to 2m, at velocities ranging from 0.002m/s to 6.5 m/s, and with normal stresses ranging from 2-22 MPa for gouge and 5-100MPa for bare surfaces. Our results demonstrate that the friction coefficient (μ) of powdered serpentine is significantly larger than that of bare surfaces under otherwise identical conditions. Bare surface friction decreases over a weakening distance of a few centimeters to a nominally steady-state value of ~0.1 at velocities greater than 0.1m/s. The nominal steady-state friction decreases non-linearly with increasing normal stress from 0.14 to 0.045 at 5 and ~100MPa respectfully at a slip velocity of 1m/s. Additionally, the recovery of frictional strength during deceleration depends on total displacement; samples slipped for ~50mm recover faster than samples slipped for ~0.5m. Microstructural analysis of bare surfaces deformed at the highest normal stresses revealed translucent glass-like material on the slip surfaces and XRD analysis of wear material revealed an increasing presence of olivine and enstatite with increasing normal stress. In contrast, gouge requires an order of magnitude higher velocity than bare surfaces to induce frictional weakening, has a larger weakening distance and higher steady state friction values for equivalent deformation conditions. Furthermore, we observe a strong normal stress dependence of the nominal steady state friction and the weakening distance of ARS and LRS gouge from 0.51 to 0.39 and from 25-10cm at 4MPa and 22MPa, respectfully, for at a slip velocity of 1m/s. Strain was localized onto a shear surface in the range of 100-300 microns wide in all gouge samples deformed at >10cm/s and XRD analyses revealed the presence of olivine and enstatite in samples with the most weakening and none in samples with no weakening. Our results indicate that dynamic weakening occurs in gouge at low normal stress in response to strain localization and shear heating of the slip surface. However, because more initial displacement is required to localize strain, weakening initiates at higher velocities and after larger weakening distances than bare surfaces. At higher normal stress, localization occurs after less displacement and the differences between gouge and bare-surface friction diminish; extrapolation of our data suggests that the behavior of serpentine gouge will approach that of bare surfaces at normal stresses ≥60 MPa.
New reference materials for nitrogen-isotope-ratio measurements
Böhlke, John Karl; Gwinn, C. J.; Coplen, T. B.
1993-01-01
Three new reference materials were manufactured for calibration of relative stable nitrogen-isotope-ratio measurements: USGS25 (ammonium sulfate) d15N' = -30 per mil; USGS26 (ammonium sulfate) d15N' = +54 per mil; USGS32 (potassium nitrate) d15N' = +180 per mil, where d15N', relative to atmospheric nitrogen, is an approximate value subject to change following interlaboratory comparisons. These materials are isotopically homogeneous in aliquots at least as small as 10 µmol N2 (or about 1-2 mg of salt). The new reference materials greatly extend the range of d15N values of internationally distributed standards, and they allow normalization of d15N measurements over almost the full range of known natural isotope variation on Earth. The methods used to produce these materials may be adapted to produce homogeneous local laboratory standards for routine use.
Williams, Lisa; Ralphs, Rob; Gray, Paul
2017-03-21
The Asian population in Britain has grown, representing the second largest ethnic group; Bangladeshi, Pakistani, and Indian nationalities are prevalent (Jivraj, 2012 ; Office for National Statistics, 2013 ). Yet, we know relatively little about the nature and extent of their substance use. Jayakody et al. ( 2006 ) argue ethnic minority groups may be influenced by the norms and values of the dominant culture. Given recreational drug use has undergone a process of normalization in Britain (Aldridge et al., 2011 ; Parker et al., 1998 , 2002 ), we explore the degree to which this is occurring in a Bangladeshi and Pakistani community of Muslim faith in Northern England; a group typically assumed to reject substance use because of robust religious and cultural values. To examine the extent, frequency, and nature of substance use, and associated attitudes. A cross-sectional study collecting qualitative data from a sample (N = 43) of adolescents accessing a drug service and a range of professionals working with them during 2014. We also present analyses of routinely collected quantitative client data. Adolescent interviewees reported extensive personal experience smoking skunk cannabis, and professionals working in the community confirmed many young Asians smoked it. Its consumption appeared to be accommodated into the daily lives of young people and the supply of it also showed signs of acceptance. Skunk cannabis may be undergoing a process of normalization within some Asian communities in Britain. Our study has significant implications for the normalization thesis, finding evidence for normalization within a subpopulation that is typically perceived to resist this trend.
Skinner, L.V.
1959-09-29
A narrow-band frequency-modulated distance measuring system is described. Reflected wave energy is fed into a mixer circuit together with a direct wave energy portion from the transmitter. These two input signals are out of phase by an amount proportional to the distance. Two band pass filter s select two different frequency components (both multiples of transmitter modulation frequency) from the beat frequency. These component frequencies are rectified and their voltage values, which are representative of those frequencies, are compared. It has been found that these voltages will have equal values producing a null output only when an object attains a preselected distance. The null output may be utilized to operate a normally closed relay, for example. At other ranges the voltage comparison will yield a voltage sufficient to keep the relay energized. Ranges may be changed by varying the degree of modulation of the transmitter carrier frequency. A particular advantage of this system lies in its high degree of accuracy throughout a range of distances approaching zero as a minimum.
Training and overtraining markers in selected sport events.
Hartmann, U; Mester, J
2000-01-01
Varieties of symptoms are supposed to detect overtraining (OT). Besides the problems of diagnosis and analysis in elite athletes, a daily monitoring of training status takes place with measurement of the parameters serum urea (SU) and serum creatine kinase (CK); therefore, their meaningfulness will be examined, with special respect inter- and intra-individually. Data were obtained from determinations during training from athletes in rowing and athletes of international level. For 6981 SU determinations (male, N = 717; female, N = 285), a slightly asymmetric normal distribution was found (male, 80%, 5-7 mmol x L(-1); female, 75%, 4-6 mmol x L(-1)). Values for women were approximately 1.5 mmol x L(-1) lower. Individual variability was enormous; there seems little point in setting fixed value as 8.3 mmol x L(-1) for men and 7.0 mmol x L(-1) for women as a critical limit for OT. CK has also been measured and evaluated in sports as an essential parameter for determination of muscular stress. Frequency distributions of CK in 2790 samples (male, N = 497; female, N = 350) presented an asymmetric normal distribution with distinct trend toward higher values being evident for the range between 100 and 250 U x L(-1). Conspicuously elevated values occurred in the ranges 250-350 U x L(-1) and 1000-2000 U x L(-1). Men's maximal values were 3000 U x L(-1) and 1150 U x L(-1) for women. Individual variability was enormous. Athletes with chronically low CK exhibited mainly low variability; those with chronically higher values exhibited considerable variability. Establishment of both parameters should be useful to determine individual baselines from a large number of samples. Determinations should be made at least every 3 d in standardized conditions. If a large increase is observed in combination with reduced exercise tolerance after a phase of exertion (2-4 d), then the possibility of a catabolic/metabolic activity or insufficient exercise tolerance becomes much more likely.
Comparison of normalization methods for the analysis of metagenomic gene abundance data.
Pereira, Mariana Buongermino; Wallroth, Mikael; Jonsson, Viktor; Kristiansson, Erik
2018-04-20
In shotgun metagenomics, microbial communities are studied through direct sequencing of DNA without any prior cultivation. By comparing gene abundances estimated from the generated sequencing reads, functional differences between the communities can be identified. However, gene abundance data is affected by high levels of systematic variability, which can greatly reduce the statistical power and introduce false positives. Normalization, which is the process where systematic variability is identified and removed, is therefore a vital part of the data analysis. A wide range of normalization methods for high-dimensional count data has been proposed but their performance on the analysis of shotgun metagenomic data has not been evaluated. Here, we present a systematic evaluation of nine normalization methods for gene abundance data. The methods were evaluated through resampling of three comprehensive datasets, creating a realistic setting that preserved the unique characteristics of metagenomic data. Performance was measured in terms of the methods ability to identify differentially abundant genes (DAGs), correctly calculate unbiased p-values and control the false discovery rate (FDR). Our results showed that the choice of normalization method has a large impact on the end results. When the DAGs were asymmetrically present between the experimental conditions, many normalization methods had a reduced true positive rate (TPR) and a high false positive rate (FPR). The methods trimmed mean of M-values (TMM) and relative log expression (RLE) had the overall highest performance and are therefore recommended for the analysis of gene abundance data. For larger sample sizes, CSS also showed satisfactory performance. This study emphasizes the importance of selecting a suitable normalization methods in the analysis of data from shotgun metagenomics. Our results also demonstrate that improper methods may result in unacceptably high levels of false positives, which in turn may lead to incorrect or obfuscated biological interpretation.
Pessoa, Isabela M B S; Houri Neto, Miguel; Montemezzo, Dayane; Silva, Luisa A M; Andrade, Armèle Dornelas De; Parreira, Verônica F
2014-01-01
The maximum static respiratory pressures, namely the maximum inspiratory pressure (MIP) and maximum expiratory pressure (MEP), reflect the strength of the respiratory muscles. These measures are simple, non-invasive, and have established diagnostic and prognostic value. This study is the first to examine the maximum respiratory pressures within the Brazilian population according to the recommendations proposed by the American Thoracic Society and European Respiratory Society (ATS/ERS) and the Brazilian Thoracic Association (SBPT). To establish reference equations, mean values, and lower limits of normality for MIP and MEP for each age group and sex, as recommended by the ATS/ERS and SBPT. We recruited 134 Brazilians living in Belo Horizonte, MG, Brazil, aged 20-89 years, with a normal pulmonary function test and a body mass index within the normal range. We used a digital manometer that operationalized the variable maximum average pressure (MIP/MEP). At least five tests were performed for both MIP and MEP to take into account a possible learning effect. We evaluated 74 women and 60 men. The equations were as follows: MIP=63.27-0.55 (age)+17.96 (gender)+0.58 (weight), r(2) of 34% and MEP= - 61.41+2.29 (age) - 0.03(age(2))+33.72 (gender)+1.40 (waist), r(2) of 49%. In clinical practice, these equations could be used to calculate the predicted values of MIP and MEP for the Brazilian population.
NASA Astrophysics Data System (ADS)
Wei, Linsheng; Xu, Min; Yuan, Dingkun; Zhang, Yafang; Hu, Zhaoji; Tan, Zhihong
2014-10-01
The electron drift velocity, electron energy distribution function (EEDF), density-normalized effective ionization coefficient and density-normalized longitudinal diffusion velocity are calculated in SF6-O2 and SF6-Air mixtures. The experimental results from a pulsed Townsend discharge are plotted for comparison with the numerical results. The reduced field strength varies from 40 Td to 500 Td (1 Townsend=10-17 V·cm2) and the SF6 concentration ranges from 10% to 100%. A Boltzmann equation associated with the two-term spherical harmonic expansion approximation is utilized to gain the swarm parameters in steady-state Townsend. Results show that the accuracy of the Boltzmann solution with a two-term expansion in calculating the electron drift velocity, electron energy distribution function, and density-normalized effective ionization coefficient is acceptable. The effective ionization coefficient presents a distinct relationship with the SF6 content in the mixtures. Moreover, the E/Ncr values in SF6-Air mixtures are higher than those in SF6-O2 mixtures and the calculated value E/Ncr in SF6-O2 and SF6-Air mixtures is lower than the measured value in SF6-N2. Parametric studies conducted on these parameters using the Boltzmann analysis offer substantial insight into the plasma physics, as well as a basis to explore the ozone generation process.
NASA Astrophysics Data System (ADS)
Smith, David R. R.; Patterson, Roy D.
2005-11-01
Glottal-pulse rate (GPR) and vocal-tract length (VTL) are related to the size, sex, and age of the speaker but it is not clear how the two factors combine to influence our perception of speaker size, sex, and age. This paper describes experiments designed to measure the effect of the interaction of GPR and VTL upon judgements of speaker size, sex, and age. Vowels were scaled to represent people with a wide range of GPRs and VTLs, including many well beyond the normal range of the population, and listeners were asked to judge the size and sex/age of the speaker. The judgements of speaker size show that VTL has a strong influence upon perceived speaker size. The results for the sex and age categorization (man, woman, boy, or girl) show that, for vowels with GPR and VTL values in the normal range, judgements of speaker sex and age are influenced about equally by GPR and VTL. For vowels with abnormal combinations of low GPRs and short VTLs, the VTL information appears to decide the sex/age judgement.
A study on the trinucleotide repeat associated with Huntington`s disease in the Chinese
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bing-wen Soong; Jih-tsuu Wang
1994-09-01
Analysis of the polymorphic (CAG)n repeat in the hungingtin gene in the chinese confirmed the presence of an expanded repeat on all Huntington`s disease chromosomes. Measurement of the specific CAG repeat sequence in 34 HD chromosomes from 15 unrelated families and 190 control chromosomes from the Chinese population showed a range from 9 to 29 repeats in normal subjects and 40 to 58 in affected subjects. The size distributions of normal and affected alleles did not overlap. A clear correlation bewteen early onset of symptoms and very high repeat number was seen, but the spread of the age-at-onset in themore » major repeat range producing characteristic HD it too wide to be of diagnostic value. There was also variability in the transmitted repeat size for both sexes in the HD size range. Maternal HD alleles showed a moderate instability with a preponderance of size decrease, while paternal HD alleles had a tendency to increase in repeat size on transmission, the degree of which appeared proportional to the initial size.« less
Creatine and guanidinoacetate reference values in a French population.
Joncquel-Chevalier Curt, Marie; Cheillan, David; Briand, Gilbert; Salomons, Gajja S; Mention-Mulliez, Karine; Dobbelaere, Dries; Cuisset, Jean-Marie; Lion-François, Laurence; Des Portes, Vincent; Chabli, Allel; Valayannopoulos, Vassili; Benoist, Jean-François; Pinard, Jean-Marc; Simard, Gilles; Douay, Olivier; Deiva, Kumaran; Tardieu, Marc; Afenjar, Alexandra; Héron, Delphine; Rivier, François; Chabrol, Brigitte; Prieur, Fabienne; Cartault, François; Pitelet, Gaëlle; Goldenberg, Alice; Bekri, Soumeya; Gerard, Marion; Delorme, Richard; Porchet, Nicole; Vianey-Saban, Christine; Vamecq, Joseph
2013-11-01
Creatine and guanidinoacetate are biomarkers of creatine metabolism. Their assays in body fluids may be used for detecting patients with primary creatine deficiency disorders (PCDD), a class of inherited diseases. Their laboratory values in blood and urine may vary with age, requiring that reference normal values are given within the age range. Despite the long known role of creatine for muscle physiology, muscle signs are not necessarily the major complaint expressed by PCDD patients. These disorders drastically affect brain function inducing, in patients, intellectual disability, autistic behavior and other neurological signs (delays in speech and language, epilepsy, ataxia, dystonia and choreoathetosis), being a common feature the drop in brain creatine content. For this reason, screening of PCDD patients has been repeatedly carried out in populations with neurological signs. This report is aimed at providing reference laboratory values and related age ranges found for a large scale population of patients with neurological signs (more than 6 thousand patients) previously serving as a background population for screening French patients with PCDD. These reference laboratory values and age ranges compare rather favorably with literature values for healthy populations. Some differences are also observed, and female participants are discriminated from male participants as regards to urine but not blood values including creatine on creatinine ratio and guanidinoacetate on creatinine ratio values. Such gender differences were previously observed in healthy populations; they might be explained by literature differential effects of testosterone and estrogen in adolescents and adults, and by estrogen effects in prepubertal age on SLC6A8 function. Finally, though they were acquired on a population with neurological signs, the present data might reasonably serve as reference laboratory values in any future medical study exploring abnormalities of creatine metabolism and transport. © 2013 Elsevier Inc. All rights reserved.
Evaluation of the 235 U resonance parameters to fit the standard recommended values
Leal, Luiz; Noguere, Gilles; Paradela, Carlos; ...
2017-09-13
A great deal of effort has been dedicated to the revision of the standard values in connection with the neutron interaction for some actinides. While standard data compilation are available for decades nuclear data evaluations included in existing nuclear data libraries (ENDF, JEFF, JENDL, etc.) do not follow the standard recommended values. Indeed, the majority of evaluations for major actinides do not conform to the standards whatsoever. In particular, for the n + 235U interaction the only value in agreement with the standard is the thermal fission cross section. We performed a resonance re-evaluation of the n + 235U interactionmore » in order to address the issues regarding standard values in the energy range from 10-5 eV to 2250 eV. Recently, 235U fission cross-section measurements have been performed at the CERN Neutron Time-o-Flight facility (TOF), known as n_TOF, in the energy range from 0.7 eV to 10 keV. The data were normalized according to the recommended standard of the fission integral in the energy range 7.8 eV to 11 eV. As a result, the n_TOF averaged fission cross sections above 100 eV are in good agreement with the standard recommended values. The n_TOF data were included in the 235U resonance analysis that was performed with the code SAMMY. In addition to the average standard values related to the fission cross section, standard thermal values for fission, capture, and elastic cross sections were also included in the evaluation. Our paper presents the procedure used for re-evaluating the 235U resonance parameters including the recommended standard values as well as new cross section measurements.« less
Evaluation of the 235 U resonance parameters to fit the standard recommended values
DOE Office of Scientific and Technical Information (OSTI.GOV)
Leal, Luiz; Noguere, Gilles; Paradela, Carlos
A great deal of effort has been dedicated to the revision of the standard values in connection with the neutron interaction for some actinides. While standard data compilation are available for decades nuclear data evaluations included in existing nuclear data libraries (ENDF, JEFF, JENDL, etc.) do not follow the standard recommended values. Indeed, the majority of evaluations for major actinides do not conform to the standards whatsoever. In particular, for the n + 235U interaction the only value in agreement with the standard is the thermal fission cross section. We performed a resonance re-evaluation of the n + 235U interactionmore » in order to address the issues regarding standard values in the energy range from 10-5 eV to 2250 eV. Recently, 235U fission cross-section measurements have been performed at the CERN Neutron Time-o-Flight facility (TOF), known as n_TOF, in the energy range from 0.7 eV to 10 keV. The data were normalized according to the recommended standard of the fission integral in the energy range 7.8 eV to 11 eV. As a result, the n_TOF averaged fission cross sections above 100 eV are in good agreement with the standard recommended values. The n_TOF data were included in the 235U resonance analysis that was performed with the code SAMMY. In addition to the average standard values related to the fission cross section, standard thermal values for fission, capture, and elastic cross sections were also included in the evaluation. Our paper presents the procedure used for re-evaluating the 235U resonance parameters including the recommended standard values as well as new cross section measurements.« less
Evaluation of the 235U resonance parameters to fit the standard recommended values
NASA Astrophysics Data System (ADS)
Leal, Luiz; Noguere, Gilles; Paradela, Carlos; Durán, Ignacio; Tassan-Got, Laurent; Danon, Yaron; Jandel, Marian
2017-09-01
A great deal of effort has been dedicated to the revision of the standard values in connection with the neutron interaction for some actinides. While standard data compilation are available for decades nuclear data evaluations included in existing nuclear data libraries (ENDF, JEFF, JENDL, etc.) do not follow the standard recommended values. Indeed, the majority of evaluations for major actinides do not conform to the standards whatsoever. In particular, for the n + 235U interaction the only value in agreement with the standard is the thermal fission cross section. A resonance re-evaluation of the n + 235U interaction has been performed to address the issues regarding standard values in the energy range from 10-5 eV to 2250 eV. Recently, 235U fission cross-section measurements have been performed at the CERN Neutron Time-of-Flight facility (TOF), known as n_TOF, in the energy range from 0.7 eV to 10 keV. The data were normalized according to the recommended standard of the fission integral in the energy range 7.8 eV to 11 eV. As a result, the n_TOF averaged fission cross sections above 100 eV are in good agreement with the standard recommended values. The n_TOF data were included in the 235U resonance analysis that was performed with the code SAMMY. In addition to the average standard values related to the fission cross section, standard thermal values for fission, capture, and elastic cross sections were also included in the evaluation. This paper presents the procedure used for re-evaluating the 235U resonance parameters including the recommended standard values as well as new cross section measurements.
Kalkan, Erol; Kwong, Neal S.
2014-01-01
According to the regulatory building codes in the United States (e.g., 2010 California Building Code), at least two horizontal ground motion components are required for three-dimensional (3D) response history analysis (RHA) of building structures. For sites within 5 km of an active fault, these records should be rotated to fault-normal/fault-parallel (FN/FP) directions, and two RHAs should be performed separately (when FN and then FP are aligned with the transverse direction of the structural axes). It is assumed that this approach will lead to two sets of responses that envelope the range of possible responses over all nonredundant rotation angles. This assumption is examined here, for the first time, using a 3D computer model of a six-story reinforced-concrete instrumented building subjected to an ensemble of bidirectional near-fault ground motions. Peak values of engineering demand parameters (EDPs) were computed for rotation angles ranging from 0 through 180° to quantify the difference between peak values of EDPs over all rotation angles and those due to FN/FP direction rotated motions. It is demonstrated that rotating ground motions to FN/FP directions (1) does not always lead to the maximum responses over all angles, (2) does not always envelope the range of possible responses, and (3) does not provide maximum responses for all EDPs simultaneously even if it provides a maximum response for a specific EDP.
Kroner, Kevin; Cooley, Katie; Hoey, Seamus; Hetzel, Scott J; Bleedorn, Jason A
2017-01-01
To evaluate the reliability of radial torsion assessment in dogs using computed tomography (CT). Cadaveric and retrospective observational clinical study. Thoracic limbs (n = 40) from bilateral normal cadaveric canine specimens (10 pairs) and unilateral antebrachial angular limb deformity (ALD) dogs (10 uniapical and 10 biapical deformities). Limbs were evaluated using CT. Frontal, sagittal, and axial plane (torsion) values were obtained using published guidelines and compared between groups and limbs. Radial torsion reliability was assessed among 3 observers using intraclass correlation coefficients (ICC). The mean (±SD) radial torsion of normal dogs was 3.6° ± 6.4° and contained a significant right to left limb variation of 2.6°. Mean radial torsion in uniapical ALD limbs (3.6° ± 18.7°) was not significantly different from biapical ALD limbs (8.9° ± 17.9°). There was a wide range of torsion values in normal and ALD limbs. The interobserver reliability was excellent (ICC > 0.8) for normal dogs, good (0.73) for uniapical, and excellent (0.89) for biapical ALD limbs. The intraobserver reliability was excellent (>0.8) for all groups. There was a small side-to-side variation of radial torsion in normal dogs. With directed training, torsion assessment using CT is reliable in dogs with and without antebrachial bone deformity. © 2016 The American College of Veterinary Surgeons.
NASA Astrophysics Data System (ADS)
Marcó P., L. M.; Jiménez, E.; Hernández C., E. A.; Rojas, A.; Greaves, E. D.
2001-11-01
The method of quantification using the Compton peak as an internal standard, developed in a previous work, was applied to the routine determination of Fe, Cu, Zn and Se in serum samples from normal individuals and cancer patients by total reflection X-ray fluorescence spectrometry. Samples were classified according to age and sex of the donor, in order to determine reference values for normal individuals. Results indicate that the Zn/Cu ratio and the Cu concentration could prove to be useful tools for cancer diagnosis. Significant differences in these parameters between the normal and cancer group were found for all age ranges. The multielemental character of the technique, coupled with the small amounts of sample required and the short analysis time make it a valuable tool in clinical analysis.
Performance analysis of hybrid vibrational energy harvesters with experimental verification
NASA Astrophysics Data System (ADS)
Sriramdas, Rammohan; Pratap, Rudra
2018-07-01
In the present work, performance indices for a hybrid energy harvester (HEH) that is composed of piezoelectric and electrodynamic or electromagnetic mechanisms of energy conversion are analyzed. Performance of a HEH is defined in terms of Q-normalized power factor and efficiency of conversion. They are observed to acutely depend on coupling strength or figures of merit in both piezoelectric and electrodynamic domains. The influence of figures of merit on the Q-normalized power factor, and the limits of conversion efficiency are explored. Based on the studies, a suitable range for figures of merit that would maximize both Q-normalized power factor and conversion efficiency in hybrid harvesters is proposed. The proposed idea is verified experimentally for the appropriate values of figures of merit and efficiencies by fabricating and testing four experimental models of the HEHs.
Bancone, Germana; Gornsawun, Gornpan; Chu, Cindy S; Porn, Pen; Pal, Sampa; Bansil, Pooja; Domingo, Gonzalo J; Nosten, Francois
2018-01-01
Glucose-6-phosphate dehydrogenase (G6PD) deficiency is the most common enzymopathy in the human population affecting an estimated 8% of the world population, especially those living in areas of past and present malaria endemicity. Decreased G6PD enzymatic activity is associated with drug-induced hemolysis and increased risk of severe neonatal hyperbilirubinemia leading to brain damage. The G6PD gene is on the X chromosome therefore mutations cause enzymatic deficiency in hemizygote males and homozygote females while the majority of heterozygous females have an intermediate activity (between 30-80% of normal) with a large distribution into the range of deficiency and normality. Current G6PD qualitative tests are unable to diagnose G6PD intermediate activities which could hinder wide use of 8-aminoquinolines for Plasmodium vivax elimination. The aim of the study was to assess the diagnostic performances of the new Carestart G6PD quantitative biosensor. A total of 150 samples of venous blood with G6PD deficient, intermediate and normal phenotypes were collected among healthy volunteers living along the north-western Thailand-Myanmar border. Samples were analyzed by complete blood count, by gold standard spectrophotometric assay using Trinity kits and by the latest model of Carestart G6PD biosensor which analyzes both G6PD and hemoglobin. Bland-Altman comparison of the CareStart normalized G6PD values to that of the gold standard assay showed a strong bias in values resulting in poor area under-the-curve values for both 30% and 80% thresholds. Performing a receiver operator curve identified threshold values for the CareStart product equivalent to the 30% and 80% gold standard values with good sensitivity and specificity values, 100% and 92% (for 30% G6PD activity) and 92% and 94% (for 80% activity) respectively. The Carestart G6PD biosensor represents a significant improvement for quantitative diagnosis of G6PD deficiency over previous versions. Further improvements and validation studies are required to assess its utility for informing radical cure decisions in malaria endemic settings.
Gornsawun, Gornpan; Chu, Cindy S.; Porn, Pen; Pal, Sampa; Bansil, Pooja
2018-01-01
Introduction Glucose-6-phosphate dehydrogenase (G6PD) deficiency is the most common enzymopathy in the human population affecting an estimated 8% of the world population, especially those living in areas of past and present malaria endemicity. Decreased G6PD enzymatic activity is associated with drug-induced hemolysis and increased risk of severe neonatal hyperbilirubinemia leading to brain damage. The G6PD gene is on the X chromosome therefore mutations cause enzymatic deficiency in hemizygote males and homozygote females while the majority of heterozygous females have an intermediate activity (between 30–80% of normal) with a large distribution into the range of deficiency and normality. Current G6PD qualitative tests are unable to diagnose G6PD intermediate activities which could hinder wide use of 8-aminoquinolines for Plasmodium vivax elimination. The aim of the study was to assess the diagnostic performances of the new Carestart G6PD quantitative biosensor. Methods A total of 150 samples of venous blood with G6PD deficient, intermediate and normal phenotypes were collected among healthy volunteers living along the north-western Thailand-Myanmar border. Samples were analyzed by complete blood count, by gold standard spectrophotometric assay using Trinity kits and by the latest model of Carestart G6PD biosensor which analyzes both G6PD and hemoglobin. Results Bland-Altman comparison of the CareStart normalized G6PD values to that of the gold standard assay showed a strong bias in values resulting in poor area under-the-curve values for both 30% and 80% thresholds. Performing a receiver operator curve identified threshold values for the CareStart product equivalent to the 30% and 80% gold standard values with good sensitivity and specificity values, 100% and 92% (for 30% G6PD activity) and 92% and 94% (for 80% activity) respectively. Conclusion The Carestart G6PD biosensor represents a significant improvement for quantitative diagnosis of G6PD deficiency over previous versions. Further improvements and validation studies are required to assess its utility for informing radical cure decisions in malaria endemic settings. PMID:29738562
NASA Astrophysics Data System (ADS)
Rothschild, Walter G.; Cavagnat, Raymond M.
1994-03-01
We have extended the Raman spectral accumulations of the ν3 mode (A1, 367 cm-1) of liquid CHCl3-Cl-35 and its simulation in terms of an orientational equilibrium renewal process [W. G. Rothschild, R. M. Cavagnat, and P. Maraval, J. Chem. Phys. 99, 8922 (1993)] to a temperature of 338 K, about the normal boiling point of the system (335 K). The values of the best-fit parameters predict that the orientational motion of liquid chloroform, even at such a relatively high kinetic energy, is described predominantly by libratory states; their lifetime (˜1 ps) is four times longer than that of the free-rotational steps. The character of the orientational motion of the system, when traversing the range of 213 to 338 K from just above its melting to near its boiling point at about atmospheric pressure, reflects the softening of the liquid-cage structure in terms of an increasing dispersion and/or a decreasing value of the mean libration frequency, a lowering of the depth of its potential well, but near-invariance of its lifetime. Simultaneously, there is an approximately twofold increase in the lifetime of the much shorter stages of free-rotational motion. In essence, the system dynamics remain that of an assembly of librators.
NASA Astrophysics Data System (ADS)
Longinelli, Antonio; Wierzbowski, Hubert; Di Matteo, Antonella
2003-04-01
The oxygen isotopic composition of coexisting carbonate and phosphate from belemnite rostra was measured according to well established techniques in 42 samples of Early and Middle Jurassic age and in five samples of oyster shells. Most of the samples come from various locations in the Western Carpathians of Slovakia and Ukraine, and from central Poland. Three samples come from the Isle of Skye. The phosphate content of belemnite rostra, though variable, is systematically very low: consistently lower than about 0.3%. However, this phosphate concentration is close to that found in shells of modern marine organisms including pelecypods, gastropods and Sepia cuttlebones which, in some way, could be considered the modern belemnite counterpart. The measured oxygen isotopic composition of carbonate is within the normal range of values obtained from these fossils ranging from about -1.3 to about +0.6‰ (PDB-1) with the exception of three samples; the δ 13C values range from about -0.8 to about +2.8‰ (PDB-1). With the single exception of one sample from the Isle of Skye, the oxygen isotopic composition of phosphate from belemnite rostra ranges from +19.8 to +24.9‰ (V-SMOW), 22 of the samples measured showing δ 18O values equal to or heavier than +23.0‰. In contrast, the oyster values are considerably lighter, in the case of both carbonate and phosphate. 18O-enriched values can hardly be related to diagenetic processes that normally cause an oxygen isotope shift towards light values. If deposition temperatures are calculated from the heavily enriched values by means of the equation of Longinelli and Nuti [Earth Planet. Sci. Lett. 19 (1973) 373-376] and assuming the δ 18O of Jurassic ocean water to be equal to -1‰ taking into account the lack of ice caps during the Jurassic, the obtained temperatures range from about 8°C to about zero. These temperatures are obviously unreliable when Mesozoic palaeoceanographic conditions and palaeoclimate are taken into account. Two different hypotheses are suggested to explain these results, other hypotheses being rejected as unreliable. (1) Phosphate derived from the decaying organic matter of belemnites might have been introduced into belemnite rostra by early diagenetic fluids. If the phosphate of belemnite organic matter was isotopically heavy as happens nowadays in the flesh of molluscs, the inflow of this phosphate into the rostra could be responsible for the very positive δ 18O values shown by many belemnite rostra (this hypothesis is suggested by H.W.); (2) previous oxygen isotope measurements on Upper Cretaceous belemnites yielded δ 18O values very close to the most positive values obtained from Lower Tertiary pelecypods and fish teeth which are known to precipitate their phosphate under isotopic equilibrium conditions with seawater. These data suggest the possibility that the phosphate in belemnite rostra is primary phosphate so that the very positive data reported here can be considered the result of good preservation of the pristine isotopic composition of primary phosphate. Consequently, the only way to explain the very positive δ 18O values is to consider the oxygen isotopic composition of Jurassic ocean water to be more positive than nowadays by at least 3‰. This hypothesis is suggested by A.L. and A.D.M.
May, J C; Rains, T C; Maienthal, F J; Biddle, G N; Progar, J J
1986-10-01
Approximately 85 samples of injectable biological products regulated by the Center for Drugs and Biologics of the United States Food and Drug Administration were surveyed for the presence of 11 elements, namely aluminum, arsenic, barium, cadmium, chromium, lead, mercury, selenium, thallium and zinc, by flame and flameless methods of atomic absorption spectrometry and flame emission spectrometry. The range of products tested included whole blood, red cells, plasma, normal serum albumin, antihemophilic factor, and other products derived from blood; allergenic extracts including honey bee venom and house dust allergenic extracts; vaccines such as measles virus vaccine and typhoid vaccine; and tetanus toxoid. The metal concentrations found in the majority of these products were low or undetectable. The metal levels varied from manufacturer to manufacturer, product and lot-to-lot of the same manufacturer's products. House dust allergenic extracts had the highest concentrations of arsenic (2.4 ppm), cadmium (0.28 ppm), chromium (0.6 ppm) and lead (1.5 ppm) found in the study. A high zinc concentration (24 ppm) in an immune serum globulin was attributed to the zinc-containing rubber stopper in contact with the product. A range of 0.36-3.30 ppm aluminum was found for seven 25% normal serum albumin samples from seven manufacturers. Values of 8.2, 17 and 18 ppm aluminum were found in one manufacturer's 25% normal serum albumin. These aluminum values appeared to be the result of an anomaly in this manufacturer's production that has not been repeated to date.
NASA Technical Reports Server (NTRS)
Runckel, Jack F.; Hieser, Gerald
1961-01-01
An investigation has been conducted at the Langley 16-foot transonic tunnel to determine the loading characteristics of flap-type ailerons located at inboard, midspan, and outboard positions on a 45 deg. sweptback-wing-body combination. Aileron normal-force and hinge-moment data have been obtained at Mach numbers from 0.80 t o 1.03, at angles of attack up to about 27 deg., and at aileron deflections between approximately -15 deg. and 15 deg. Results of the investigation indicate that the loading over the ailerons was established by the wing-flow characteristics, and the loading shapes were irregular in the transonic speed range. The spanwise location of the aileron had little effect on the values of the slope of the curves of hinge-moment coefficient against aileron deflection, but the inboard aileron had the greatest value of the slope of the curves of hinge-moment coefficient against angle of attack and the outboard aileron had the least. Hinge-moment and aileron normal-force data taken with strain-gage instrumentation are compared with data obtained with pressure measurements.
An enzyme-linked immunosorbent assay for the quantification of serum platelet-bindable IgG.
Howe, S E; Lynch, D M; Lynch, J M
1984-01-01
An enzyme-linked immunosorbent assay (ELISA) using F(ab')2 peroxidase-labeled antihuman immunoglobulin and o-phenylenediamine dihydrochloride (OPD) as a substrate was developed to measure serum platelet bindable IgG (S-PBIgG). The assay was made quantitative by standardizing the number of normal "target" platelets bound to microtiter plate wells, and by incorporating quantitated IgG standards with each microtiter plate tested to prepare a standard calibration curve. By this method, S-PBIgG for normal individuals was 3.4 +/- 1.6 fg per platelet (mean +/- 1 SD; n = 40). Increased S-PBIgG levels were detected in 36 of 40 patients with clinical autoimmune thrombocytopenia (ATP), ranging from 7.0 to 85 fg per platelet. Normal S-PBIgG levels were found in 34 of 40 patients with nonimmune thrombocytopenia. This method showed a sensitivity of 90 percent, specificity of 85 percent, and in the sample population studied, a positive predictive value of 0.86 and a negative predictive value of 0.90. This assay is highly reproducible (coefficient of variation was 6.8%) and appears useful in the evaluation of patients with suspected immune-mediated thrombocytopenia.
Lung texture in serial thoracic CT scans: Assessment of change introduced by image registration1
Cunliffe, Alexandra R.; Al-Hallaq, Hania A.; Labby, Zacariah E.; Pelizzari, Charles A.; Straus, Christopher; Sensakovic, William F.; Ludwig, Michelle; Armato, Samuel G.
2012-01-01
Purpose: The aim of this study was to quantify the effect of four image registration methods on lung texture features extracted from serial computed tomography (CT) scans obtained from healthy human subjects. Methods: Two chest CT scans acquired at different time points were collected retrospectively for each of 27 patients. Following automated lung segmentation, each follow-up CT scan was registered to the baseline scan using four algorithms: (1) rigid, (2) affine, (3) B-splines deformable, and (4) demons deformable. The registration accuracy for each scan pair was evaluated by measuring the Euclidean distance between 150 identified landmarks. On average, 1432 spatially matched 32 × 32-pixel region-of-interest (ROI) pairs were automatically extracted from each scan pair. First-order, fractal, Fourier, Laws’ filter, and gray-level co-occurrence matrix texture features were calculated in each ROI, for a total of 140 features. Agreement between baseline and follow-up scan ROI feature values was assessed by Bland–Altman analysis for each feature; the range spanned by the 95% limits of agreement of feature value differences was calculated and normalized by the average feature value to obtain the normalized range of agreement (nRoA). Features with small nRoA were considered “registration-stable.” The normalized bias for each feature was calculated from the feature value differences between baseline and follow-up scans averaged across all ROIs in every patient. Because patients had “normal” chest CT scans, minimal change in texture feature values between scan pairs was anticipated, with the expectation of small bias and narrow limits of agreement. Results: Registration with demons reduced the Euclidean distance between landmarks such that only 9% of landmarks were separated by ≥1 mm, compared with rigid (98%), affine (95%), and B-splines (90%). Ninety-nine of the 140 (71%) features analyzed yielded nRoA > 50% for all registration methods, indicating that the majority of feature values were perturbed following registration. Nineteen of the features (14%) had nRoA < 15% following demons registration, indicating relative feature value stability. Student's t-tests showed that the nRoA of these 19 features was significantly larger when rigid, affine, or B-splines registration methods were used compared with demons registration. Demons registration yielded greater normalized bias in feature value change than B-splines registration, though this difference was not significant (p = 0.15). Conclusions: Demons registration provided higher spatial accuracy between matched anatomic landmarks in serial CT scans than rigid, affine, or B-splines algorithms. Texture feature changes calculated in healthy lung tissue from serial CT scans were smaller following demons registration compared with all other algorithms. Though registration altered the values of the majority of texture features, 19 features remained relatively stable after demons registration, indicating their potential for detecting pathologic change in serial CT scans. Combined use of accurate deformable registration using demons and texture analysis may allow for quantitative evaluation of local changes in lung tissue due to disease progression or treatment response. PMID:22894392
Levy, Philip T; Machefsky, Aliza; Sanchez, Aura A; Patel, Meghna D; Rogal, Sarah; Fowler, Susan; Yaeger, Lauren; Hardi, Angela; Holland, Mark R; Hamvas, Aaron; Singh, Gautam K
2016-03-01
Establishment of the range of reference values and associated variations of two-dimensional speckle-tracking echocardiography (2DSTE)-derived left ventricular (LV) strain is a prerequisite for its routine clinical adoption in pediatrics. The aims of this study were to perform a meta-analysis of normal ranges of LV global longitudinal strain (GLS), global circumferential strain (GCS), and global radial strain (GRS) measurements derived by 2DSTE in children and to identify confounding factors that may contribute to variance in reported measures. A systematic review was launched in MEDLINE, Embase, Scopus, the Cumulative Index to Nursing and Allied Health Literature, and the Cochrane Library. Search hedges were created to cover the concepts of pediatrics, STE, and left-heart ventricle. Two investigators independently identified and included studies if they reported 2DSTE-derived LV GLS, GCS, or GRS. The weighted mean was estimated by using random effects models with 95% CIs, heterogeneity was assessed using the Cochran Q statistic and the inconsistency index (I(2)), and publication bias was evaluated using the Egger test. Effects of demographic (age), clinical, and vendor variables were assessed in a metaregression. The search identified 2,325 children from 43 data sets. The reported normal mean values of GLS among the studies varied from -16.7% to -23.6% (mean, -20.2%; 95% CI, -19.5% to -20.8%), GCS varied from -12.9% to -31.4% (mean, -22.3%; 95% CI, -19.9% to -24.6%), and GRS varied from 33.9% to 54.5% (mean, 45.2%; 95% CI, 38.3% to 51.7%). Twenty-six studies reported longitudinal strain only from the apical four-chamber view, with a mean of -20.4% (95% CI, -19.8% to -21.7%). Twenty-three studies reported circumferential strain (mean, -20.3%; 95% CI, -19.4% to -21.2%) and radial strain (mean, 46.7%; 95% CI, 42.3% to 51.1%) from the short-axis view at the midventricular level. A significant apex-to-base segmental longitudinal strain gradient (P < .01) was observed in the LV free wall. There was significant between-study heterogeneity and inconsistency (I(2) > 94% and P < .001 for each strain measure), which was not explained by age, gender, body surface area, blood pressure, heart rate, frame rate, frame rate/heart rate ratio, tissue-tracking methodology, location of reported strain value along the strain curve, ultrasound equipment, or software. The metaregression showed that these effects were not significant determinants of variations among normal ranges of strain values. There was no evidence of publication bias (P = .40). This study defines reference values of 2DSTE-derived LV strain in children on the basis of a meta-analysis. In healthy children, mean LV GLS was -20.2% (95% CI, -19.5% to -20.8%), mean GCS was -22.3% (95% CI, -19.9% to -24.6%), and mean GRS was 45.2% (95% CI, 38.3% to 51.7%). LV segmental longitudinal strain has a stable apex-to-base gradient that is preserved throughout maturation. Although variations among different reference ranges in this meta-analysis were not dependent on differences in demographic, clinical, or vendor parameters, age- and vendor-specific referenced ranges were established as well. Copyright © 2016 American Society of Echocardiography. Published by Elsevier Inc. All rights reserved.
Kraus, Theo F J; Globisch, Daniel; Wagner, Mirko; Eigenbrod, Sabina; Widmann, David; Münzel, Martin; Müller, Markus; Pfaffeneder, Toni; Hackner, Benjamin; Feiden, Wolfgang; Schüller, Ulrich; Carell, Thomas; Kretzschmar, Hans A
2012-10-01
5-Methylcytosine (5 mC) in genomic DNA has important epigenetic functions in embryonic development and tumor biology. 5-Hydroxymethylcytosine (5 hmC) is generated from 5 mC by the action of the TET (Ten-Eleven-Translocation) enzymes and may be an intermediate to further oxidation and finally demethylation of 5 mC. We have used immunohistochemistry (IHC) and isotope-based liquid chromatography mass spectrometry (LC-MS) to investigate the presence and distribution of 5 hmC in human brain and brain tumors. In the normal adult brain, IHC identified 61.5% 5 hmC positive cells in the cortex and 32.4% 5 hmC in white matter (WM) areas. In tumors, positive staining of cells ranged from 1.1% in glioblastomas (GBMs) (WHO Grade IV) to 8.9% in Grade I gliomas (pilocytic astrocytomas). In the normal adult human brain, LC-MS also showed highest values in cortical areas (1.17% 5 hmC/dG [deoxyguanosine]), in the cerebral WM we measured around 0.70% 5 hmC/dG. levels were related to tumor differentiation, ranging from lowest values of 0.078% 5 hmC/dG in GBMs (WHO Grade IV) to 0.24% 5 hmC/dG in WHO Grade II diffuse astrocytomas. 5 hmC measurements were unrelated to 5 mC values. We find that the number of 5 hmC positive cells and the amount of 5 hmC/dG in the genome that has been proposed to be related to pluripotency and lineage commitment in embryonic stem cells is also associated with brain tumor differentiation and anaplasia. Copyright © 2012 UICC.
Choosing the Allometric Exponent in Covariate Model Building.
Sinha, Jaydeep; Al-Sallami, Hesham S; Duffull, Stephen B
2018-04-27
Allometric scaling is often used to describe the covariate model linking total body weight (WT) to clearance (CL); however, there is no consensus on how to select its value. The aims of this study were to assess the influence of between-subject variability (BSV) and study design on (1) the power to correctly select the exponent from a priori choices, and (2) the power to obtain unbiased exponent estimates. The influence of WT distribution range (randomly sampled from the Third National Health and Nutrition Examination Survey, 1988-1994 [NHANES III] database), sample size (N = 10, 20, 50, 100, 200, 500, 1000 subjects), and BSV on CL (low 20%, normal 40%, high 60%) were assessed using stochastic simulation estimation. A priori exponent values used for the simulations were 0.67, 0.75, and 1, respectively. For normal to high BSV drugs, it is almost impossible to correctly select the exponent from an a priori set of exponents, i.e. 1 vs. 0.75, 1 vs. 0.67, or 0.75 vs. 0.67 in regular studies involving < 200 adult participants. On the other hand, such regular study designs are sufficient to appropriately estimate the exponent. However, regular studies with < 100 patients risk potential bias in estimating the exponent. Those study designs with limited sample size and narrow range of WT (e.g. < 100 adult participants) potentially risk either selection of a false value or yielding a biased estimate of the allometric exponent; however, such bias is only relevant in cases of extrapolating the value of CL outside the studied population, e.g. analysis of a study of adults that is used to extrapolate to children.
Randomized controlled trial of a treatment for anorexia and bulimia nervosa
Bergh, Cecilia; Brodin, Ulf; Lindberg, Greger; Södersten, Per
2002-01-01
Evidence for the effectiveness of existing treatments of patients with eating disorders is weak. Here we describe and evaluate a method of treatment in a randomized controlled trial. Sixteen patients, randomly selected out of a group composed of 19 patients with anorexia nervosa and 13 with bulimia nervosa, were trained to eat and recognize satiety by using computer support. They rested in a warm room after eating, and their physical activity was restricted. The patients in the control group (n = 16) received no treatment. Remission was defined by normal body weight (anorexia), cessation of binge eating and purging (bulimia), a normal psychiatric profile, normal laboratory test values, normal eating behavior, and resumption of social activities. Fourteen patients went into remission after a median of 14.4 months (range 4.9–26.5) of treatment, but only one patient went into remission while waiting for treatment (P = 0.0057). Relapse is considered a major problem in patients who have been treated to remission. We therefore report results on a total of 168 patients who have entered our treatment program. The estimated rate of remission was 75%, and estimated time to remission was 14.7 months (quartile range 9.6 ≥ 32). Six patients (7%) of 83 who were treated to remission relapsed, but the others (93%) have remained in remission for 12 months (quartile range 6–36). Because the risk of relapse is maximal in the first year after remission, we suggest that most patients treated with this method recover. PMID:12082182
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nicod, P.; Burger, A.; Staeheli, V.
1976-05-01
Serum 3,3',5'-triiodothyronine (rT/sub 3/) was measured with a radioimmunoassay in unextracted serum. The assay was specific and reproducible. The coefficients of variation for three different sera known for high, normal, and low rT/sub 3/ concentrations between assays were 4, 6, and 9 percent and within assays 4, 9, and 7 percent, respectively. In euthyroid subjects 20 to 60 years old, rT/sub 3/ was 450 +- 200 pg/ml (mean +- SD, n = 83). Serum rT/sub 3/ was found to be increased in hyperthyroidism (range: 762 to 2581 pg/ml; n = 11) but also in acute and chronic illness (up tomore » 2400 pg/ml; n = 24) and in anorexia nervosa (536 to 1058 pg/ml; n = 7). In the latter two situations there was mostly an inverse change in serum 3,5,3'-triiodothyronine (T/sub 3/) which was in the low normal range or decreased. These findings suggest a metabolic control of thryoxine deiodination. A low serum rT/sub 3/ was found in 9 of 12 hypothyroid patients and in the serum of one chronically ill patient. Long-term treatment (1 to 7 years) with lithium carbonate slightly reduced serum rT/sub 3/, although the changes were inside the normal range. Kidney function was not found to be necessary for its production, as anephric patients had normal rT/sub 3/ values. In addition, hemodialysis increased serum rT/sub 3/, which is probably due to the heparin therapy.« less
The prescriber as moralist: values in the antidepressant debate.
Scheurich, Neil
2006-01-01
The past decade has seen a growing debate about the expanding use of psychotropic medications. Of particular concern are current antidepressants, as well as hypothetical "mood brighteners" that could modify affect and behavior in people heretofore classified as being within the normal range. This paper argues that objections to such pharmacologic applications are based on appeals to cultural values--authenticity, diversity, inwardness, and stoicism among others--that are viewed as being under increasing threat in contemporary American culture. Critiques of mood brighteners, like critiques of technological, consumer-driven culture, repudiate the ideals of shallow satisfaction and of the self as commodity. The decision to prescribe or not to prescribe a psychotropic medication in any given case is based on cultural values as well as clinical judgment.
Standardizing Foot-Type Classification Using Arch Index Values
Weil, Rich; de Boer, Emily
2012-01-01
ABSTRACT Purpose: The lack of a reliable classification standard for foot type makes drawing conclusions from existing research and clinical decisions difficult, since different foot types may move and respond to treatment differently. The purpose of this study was to determine interrater agreement for foot-type classification based on photo-box-derived arch index values. Method: For this correlational study with two raters, a sample of 11 healthy volunteers with normal to obese body mass indices was recruited from both a community weight-loss programme and a programme in physical therapy. Arch index was calculated using AutoCAD software from footprint photographs obtained via mirrored photo-box. Classification as high-arched, normal, or low-arched foot type was based on arch index values. Reliability of the arch index was determined with intra-class correlations; agreement on foot-type classification was determined using quadratic weighted kappa (κw). Results: Average arch index was 0.215 for one tester and 0.219 for the second tester, with an overall range of 0.017 to 0.370. Both testers classified 6 feet as low-arched, 9 feet as normal, and 7 feet as high-arched. Interrater reliability for the arch index was ICC=0.90; interrater agreement for foot-type classification was κw=0.923. Conclusions: Classification of foot type based on arch index values derived from plantar footprint photographs obtained via mirrored photo-box showed excellent reliability in people with varying BMI. Foot-type classification may help clinicians and researchers subdivide sample populations to better differentiate mobility, gait, or treatment effects among foot types. PMID:23729964
Herbal Traditional Chinese Medicine and suspected liver injury: A prospective study
Melchart, Dieter; Hager, Stefan; Albrecht, Sabine; Dai, Jingzhang; Weidenhammer, Wolfgang; Teschke, Rolf
2017-01-01
AIM To analyze liver tests before and following treatment with herbal Traditional Chinese Medicine (TCM) in order to evaluate the frequency of newly detected liver injury. METHODS Patients with normal values of alanine aminotransferase (ALT) as a diagnostic marker for ruling out pre-existing liver disease were enrolled in a prospective study of a safety program carried out at the First German Hospital of TCM from 1994 to 2015. All patients received herbal products, and their ALT values were reassessed 1-3 d prior to discharge. To verify or exclude causality for suspected TCM herbs, the Roussel Uclaf Causality Assessment Method (RUCAM) was used. RESULTS This report presents for the first time liver injury data derived from a prospective, hospital-based and large-scale study of 21470 patients who had no liver disease prior to treatment with herbal TCM. Among these, ALT ranged from 1 × to < 5 × upper limit normal (ULN) in 844 patients (3.93%) and suggested mild or moderate liver adaptive abnormalities. However, 26 patients (0.12%) experienced higher ALT values of ≥ 5 × ULN (300.0 ± 172.9 U/L, mean ± SD). Causality for TCM herbs was RUCAM-based probable in 8/26 patients, possible in 16/26, and excluded in 2/26 cases. Bupleuri radix and Scutellariae radix were the two TCM herbs most commonly implicated. CONCLUSION In 26 (0.12%) of 21470 patients treated with herbal TCM, liver injury with ALT values of ≥ 5 × ULN was found, which normalized shortly following treatment cessation, also substantiating causality. PMID:29085558
Massaro, F; Dolcino, M; Degrandi, R; Ferone, D; Mussap, M; Minuto, F; Giusti, M
2009-04-01
Assaying calcitonin (CT) in the wash-out fluid from fine-needle aspiration biopsies (CT-FNAB) could be useful in the diagnosis of medullary thyroid carcinoma (MTC). The aim of this study was to correlate serum CT with cytology and CT-FNAB. Twenty-seven subjects (age range 27-75 yr) were studied. FNAB was performed in a thyroid nodule (no.=16) or lymph-node (no.=1 previously operated on for MTC) or in the prevalent nodule of multinodular goiters (no.=10). CT-FNAB values obtained in 37 subjects with normal serum CT (<10 ng/l) who underwent FNAB for thyroid nodules served as a negative control. In these subjects, CTFNAB values were 8.2+/-6.4 ng/l (range 2-30 ng/l). In patients with a thyroid nodule under evaluation for MTC, serum CT and CT-FNAB values were 14.5+/-3.9 ng/l (range 10-24 ng/l) and 16.4+/-29.8 ng/l (range 2-144 ng/l), respectively. In 4 patients, CT-FNAB values were higher than the highest values found in our negative controls (30 ng/l), but cytology results were compatible with a benign thyroid lesion and pentagastrin testing was negative. In 3 cases with CT-FNAB <30 ng/l, cytology was indicative of an indeterminate or probably follicular malignant lesion and histology was negative for MTC. None of the other subjects in whom pentagastrin testing was conducted showed serum CT values >100 ng/l. Our data do not show any correlation between CT-FNAB and serum CT. In conclusion, borderline CT values in patients with thyroid nodules are not rare. Our experience suggests that CT-FNAB does not have the same importance as that reported in the literature for thyroglobulin and PTH assay in wash-out fluid after FNAB in malignant thyroid and hyperfunctioning parathyroid lesions.
Hidalgo y Teran Elizondo, Roberto; Martín Bermudo, Francisco Manuel; Peñaloza Mendez, Ricardo; Berná Amorós, Genoveva; Lara Padilla, Eleazar; Berral de la Rosa, Francisco José
2015-10-01
nutritional intake and status of soccer players has attracted not much research attention. Many soccer players follow an inadequate nutritional intake and have a poor nutritional status. This is relevant in youngsters soccer players, in order to improve performance and promote healthy dietary practices. analyze anthropometric characterizes, evaluate nutritional intake and status, dietary habits and pre- and post-exercise meals in elite teenagers soccer players. seventy-two young male soccer players (15-20 years) from four junior teams of a soccer Club from the Mexican National Soccer League were measured for height, seat height, weight, 6 skinfolds, 6 diameters and 7 circumferences, height-for-age and BMI-for-age values. Skin, adipose, muscle, bone and residual tissue masses were calculated with the Ross and Kerr equation. Resting energy expenditure and intake was also measured. Daily dietary intake was self-recorded for 4 consecutive days (excluding the match day) using a digital food-weighing scale and a food record questionnaire. Dietary analysis was performed using the NutriBase 7 Clinical software. Several biochemical values were determined. One-way analysis of variance (ANOVA) and post hoc testing was performed using t-tests with a Bonferroni correction. all soccer players were within the normal range values for anthropometric parameters studies, when compared with other adolescent elite soccer teams. Values of plasma glucose, urea, creatinine, uric acid, lipid profile and total proteins were within normal range for young adult population, although albumin levels were high. Moreover, 14% and 20% of soccer players presented hyperuricemia and elevated total cholesterol levels respectively. Energy expenditure and intake were within normal range for all teenager elite soccer players. However, two teams shower significant lower intakes than demands. All macronutrient intakes were within recommendations, except protein that was higher. Micronutrient intake exceeded the recommendations for general population. Soccer players had pre- and post-exercise meals with an appropriate range of carbohydrates. Food intake was mainly based on cereals, derivatives and potatoes; meat, poultry, fish, shellfish and eggs and biscuits and confectionery and poor in fruit, vegetables and milk and dairy products. the population of soccer players did not have optimal nutritional habits. However, their nutritional intake and status was better than in other published studies. The main problems of these teams were that they had a high protein diet and that in some teams the nutritional intake was not enough to cover the demands. Finally, nutritional intake was found to be of poor quality. Thus, we recommend nutritional education for soccer players of these teams. Copyright AULA MEDICA EDICIONES 2014. Published by AULA MEDICA. All rights reserved.
Asymmetric vestibular evoked myogenic potentials in unilateral Menière patients
Wit, H. P.
2010-01-01
Vestibular evoked myogenic potentials (VEMPs) were measured in 22 unilateral Menière patients with monaural and binaural stimulation with 250 and 500 Hz tone bursts. For all measurement situations significantly lower VEMP amplitudes were on average measured at the affected side compared to the unaffected side. Unilateral Menière patients have, in contrast to normal subjects, asymmetric VEMPs, indicating a permanently affected vestibular (most likely otolith) system at the side of hearing loss. The diagnostic value of VEMP amplitude asymmetry measurement in individual patients is low, because of the large overlap of the VEMP amplitude asymmetry range for unilateral Menière patients with that for normal subjects. PMID:20665043
Note on the artefacts in SRIM simulation of sputtering
NASA Astrophysics Data System (ADS)
Shulga, V. I.
2018-05-01
The computer simulation program SRIM, unlike other well-known programs (MARLOWE, TRIM.SP, etc.), predicts non-zero values of the sputter yield at glancing ion bombardment of smooth amorphous targets and, for heavy ions, greatly underestimates the sputter yield at normal incidence. To understand the reasons for this, the sputtering of amorphous silicon bombarded with different ions was modeled here using the author's program OKSANA. Most simulations refer to 1 keV Xe ions, and angles of incidence cover range from 0 (normal incidence) to almost 90°. It has been shown that SRIM improperly simulates the initial stage of the sputtering process. Some other artefacts in SRIM calculations of sputtering are also revealed and discussed.
NASA Technical Reports Server (NTRS)
Frost, J. D., Jr.
1977-01-01
Comparative data for further assessments of the EEG alterations seen during Skylab are elaborated. The variability of alpha, beta, theta, and delta EEG characteristics was analyzed with quantitative computer techniques in a group of six normal individuals over a period of two months, and the EEG effects of a prolonged period of bed rest were evaluated in two subjects. The results confirm that the inflight EEG changes seen during Skylab are statistically significant, but the absolute values obtained for the various parameters do not exceed the maximal range expected in a normal population. Further, the EEG manifestations of extended bed rest do not appear similar to those of space flight.
[Thyroid function in patients with anorexia nervosa and depression].
Natori, Y; Yamaguchi, N; Koike, S; Aoyama, A; Tsuchibuchi, S; Kojyo, K; Demura, R
1994-12-01
Thyroid hormone levels were measured in 21 patients with anorexia nervosa, 15 patients with depression and 16 patients with severe depression and were compared with those in 53 normal subjects. In anorexia nervosa and severe depressed patients, serum T3, T4, fT3, fT4 and T3/T4 ratio showed significantly lower values than those in normal subjects. However there was no difference between depressed patients and normal subjects. The serum TSH levels were within normal range in all of the studied subjects. Thus, thyroid hormone levels in severe depressed patients were similar to those in anorexia nervosa and the changes were inversely related to disease conditions. The supplementation of thyroid hormones to antidepressant relieved clinical symptoms in some of the severe depressed patients. These results suggested that the changes in thyroid hormone levels in anorexia nervosa and severe depression were mainly due to impaired conversion of T4 to T3 by increased cortisol secretion through emotional stress.
Evaluative procedures to detect, characterize, and assess the severity of diabetic neuropathy.
Dyck, P J
1991-01-01
Minimal criteria for diabetic neuropathy need to be defined and universally applied. Standardized evaluative procedures need to be agreed and normal ranges determined from healthy volunteers. Types and stages of neuropathy should be established and assessments performed on representative populations of both Type 1 and Type 2 diabetic patients. Potential minimal criteria include absent ankle reflexes and vibratory sensation, and abnormalities of nerve conduction. However, the preferred criterion is the identification of more than two statistically defined abnormalities among symptoms and deficits, nerve conduction, quantitative sensory examination or quantitative autonomic examination. Various evaluative procedures are available. Symptoms should be assessed and scores can be assigned to neurological deficits. However, assessments of nerve conduction provide the most specific, objective, sensitive, and repeatable procedures, although these may be the least meaningful. Many techniques are available for quantitative sensory examination, but are poorly standardized and normal values are not available. For quantitative autonomic examination, tests are available for the adequacy of cardiovascular and peripheral vascular reflexes and increasingly for other autonomic functions. In any assessment of nerve function the conditions should be optimized and standardized, and stimuli defined. Specific instructions should be given and normal ranges established in healthy volunteers.
A step function model to evaluate the real monetary value of man-sievert with real GDP.
Na, Seong H; Kim, Sun G
2009-01-01
For use in a cost-benefit analysis to establish optimum levels of radiation protection in Korea under the ALARA principle, we introduce a discrete step function model to evaluate man-sievert monetary value in the real economic value. The model formula, which is unique and country-specific, is composed of real GDP, the nominal risk coefficient for cancer and hereditary effects, the aversion factor against radiation exposure, and average life expectancy. Unlike previous researches on alpha-value assessment, we show different alpha values in the real term, differentiated with respect to the range of individual doses, which would be more realistic and informative for application to the radiation protection practices. GDP deflators of economy can reflect the society's situations. Finally, we suggest that the Korean model can be generalized simply to other countries without normalizing any country-specific factors.
Tryptase serum level as a possible indicator of scombroid syndrome.
Ricci, Giorgio; Zannoni, Massimo; Cigolini, Davide; Caroselli, Costantino; Codogni, Rosalia; Caruso, Beatrice; Bonello, Elisa; Rocca, Giampaolo P
2010-03-01
Scombroid syndrome (histamine fish poisoning--HFP) is a complex of symptoms caused by biogenic amines, mainly histamine, contained in seafood. The diagnosis of HFP is quite difficult as the symptoms of this particular condition are similar to the symptoms of a normal allergic syndrome. We have collected 10 cases (3 male and 7 female) of HFP and 50 non-HFP patients (35 female and 15 male) with allergic disorders, all from the Emergency Department of Ospedale Civile Maggiore in Verona. As expected, tryptase serum concentrations of most of the patients with allergic or anaphylactic disorders were increased above normal value (24.4+/-8.0 ng/mL mean+/-SD, normal value<11 ng/mL), whereas the tryptase serum concentrations of all the 10 patients with HFP were within the normal range (8.1+/-1.8 ng/mL). Our data suggest that tryptase serum concentrations can discriminate between the allergic and HFP syndromes. As the tryptase half-life is 90-120 min, blood samples must be taken 1-2 h from the beginning of symptoms. Finding a biomarker could help physicians to formulate a correct diagnosis and thus in choosing the best therapeutic strategy. In this work, we analyzed the role of tryptase serum concentrations to differentiate real allergic syndromes from the HFP syndrome, which causes similar histamine-mediated effects by a different mechanism.
Marsh collapse thresholds for coastal Louisiana estimated using elevation and vegetation index data
Couvillion, Brady R.; Beck, Holly
2013-01-01
Forecasting marsh collapse in coastal Louisiana as a result of changes in sea-level rise, subsidence, and accretion deficits necessitates an understanding of thresholds beyond which inundation stress impedes marsh survival. The variability in thresholds at which different marsh types cease to occur (i.e., marsh collapse) is not well understood. We utilized remotely sensed imagery, field data, and elevation data to help gain insight into the relationships between vegetation health and inundation. A Normalized Difference Vegetation Index (NDVI) dataset was calculated using remotely sensed data at peak biomass (August) and used as a proxy for vegetation health and productivity. Statistics were calculated for NDVI values by marsh type for intermediate, brackish, and saline marsh in coastal Louisiana. Marsh-type specific NDVI values of 1.5 and 2 standard deviations below the mean were used as upper and lower limits to identify conditions indicative of collapse. As marshes seldom occur beyond these values, they are believed to represent a range within which marsh collapse is likely to occur. Inundation depth was selected as the primary candidate for evaluation of marsh collapse thresholds. Elevation relative to mean water level (MWL) was calculated by subtracting MWL from an elevation dataset compiled from multiple data types including light detection and ranging (lidar) and bathymetry. A polynomial cubic regression was used to examine a random subset of pixels to determine the relationship between elevation (relative to MWL) and NDVI. The marsh collapse uncertainty range values were found by locating the intercept of the regression line with the 1.5 and 2 standard deviations below the mean NDVI value for each marsh type. Results indicate marsh collapse uncertainty ranges of 30.7–35.8 cm below MWL for intermediate marsh, 20–25.6 cm below MWL for brackish marsh, and 16.9–23.5 cm below MWL for saline marsh. These values are thought to represent the ranges of inundation depths within which marsh collapse is probable.
Investigations of magnesium, histamine and immunoglobulins dynamics in acute urticaria.
Mureşan, D; Oană, A; Nicolae, I; Alecu, M; Moşescu, L; Benea, V; Flueraş, M
1990-01-01
In 42 urticaria patients, magnesium, histamine and IgE were dosed. Magnesium, IgE and histamine variations were followed in urticaria evolution, during acute phase and clinical remission. We noticed magnesium, histamine, IgE values variations depending on disease evolution and applied therapeutic scheme. Therefore: At disease starting point, histamine presented 3.5 times higher values than the normal ones. The value decreases following a curve which tends to reach normal values during clinical remission. At disease starting point, magnesium presented values under the inferior limit of the normal, 0.5 m mol/L respectively, as a mean. The value increases towards the normal limit during clinical remission. Immunoglobulins E follow a similar curve to histamine one, presenting 1,250 U/L values at the starting point, that, under medication, influence decrease between normal limits (800 U/L), during clinical remission. Analyzing the variations of biochemical parameters, the authors emphasize magnesium substitution treatment in urticaria.
19 CFR 351.408 - Calculation of normal value of merchandise from nonmarket economy countries.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 19 Customs Duties 3 2010-04-01 2010-04-01 false Calculation of normal value of merchandise from nonmarket economy countries. 351.408 Section 351.408 Customs Duties INTERNATIONAL TRADE ADMINISTRATION, DEPARTMENT OF COMMERCE ANTIDUMPING AND COUNTERVAILING DUTIES Calculation of Export Price, Constructed Export Price, Fair Value, and Normal Value §...
Kusanovic, Juan Pedro; Romero, Roberto; Hassan, Sonia S.; Gotsch, Francesca; Edwin, Samuel; Erez, Offer; Mittal, Pooja; Mazaki-Tovi, Shali; Soto, Eleazar; Than, Nandor Gabor; Friel, Lara A.; Chaiworapongsa, Tinnakorn; Yoon, Bo Hyun; Espinoza, Jimmy
2008-01-01
Objective Women with preeclampsia and those who deliver small for gestational age (SGA) neonates are characterized by intravascular inflammation (T helper 1 (Th1)-biased immune response). There is controversy about the T helper 2 (Th2) response in preeclampsia and SGA. CD30, a member of the tumor necrosis factor receptor superfamily, is preferentially expressed in vitro and in vivo by activated T cells producing Th2-type cytokines. Its soluble form (sCD30) has been proposed to be an index of Th2 immune response. The objective of this study was to determine whether maternal serum concentration of sCD30 changes with normal pregnancy, as well as in mothers with preeclampsia and those who deliver SGA neonates. Methods This cross-sectional study included patients in the following groups: (1) non-pregnant women (N=49); (2) patients with a normal pregnancy (N=89); (3) patients with preeclampsia (N=100); and (4) patients who delivered an SGA neonates (N=78). Maternal serum concentration of sCD30 was measured by a specific and sensitive enzyme-linked immunoassay. Non-parametric tests with post-hoc analysis were used for comparisons. A p value <0.05 was considered statistically significant. Results (1) The median sCD30 serum concentration of pregnant women was significantly higher than that of non-pregnant women (median: 29.7 U/mL, range: 12.2-313.2 vs. median: 23.2 U/mL, range: 14.6-195.1, respectively; p=0.01); (2) Patients with preeclampsia had a significantly lower median serum concentration of sCD30 than normal pregnant women (median: 24.7 U/mL, range: 7.6-71.2 vs. median: 29.7 U/mL, range: 12.2-313.2, respectively; p<0.05); (3) Mothers with SGA neonates had a lower median concentration of sCD30 than normal pregnant women (median: 23.4 U/mL, range: 7.1-105.3 vs. median: 29.7 U/mL, range: 12.2-313.2, respectively; p<0.05); and (4) There was no significant correlation (r=-0.059, p=0.5) between maternal serum sCD30 concentration and gestational age (19-38 weeks) in normal pregnant women. Conclusions (1) Patients with preeclampsia and those who deliver a SGA neonate had a significantly lower serum concentration of sCD30 than normal pregnant women; (2) This finding is consistent with the view that preeclampsia and SGA are associated with a polarized Th1 immune response and, perhaps, a reduced Th2 response. PMID:17853188
DOE Office of Scientific and Technical Information (OSTI.GOV)
Altazi, B; Fernandez, D; Zhang, G
Purpose: Site-specific investigations of the role of Radiomics in cancer diagnosis and therapy are needed. We report of the reproducibility of quantitative image features over different discrete voxel levels in PET/CT images of cervical cancer. Methods: Our dataset consisted of the pretreatment PET/CT scans from a cohort of 76 patients diagnosed with cervical cancer, FIGO stage IB-IVA, age range 31–76 years, treated with external beam radiation therapy to a dose range between 45–50.4 Gy (median dose: 45 Gy), concurrent cisplatin chemotherapy and MRI-based Brachytherapy to a dose of 20–30 Gy (median total dose: 28 Gy). Two board certified radiation oncologistsmore » delineated Metabolic Tumor volume (MTV) for each patient. Radiomics features were extracted based on 32, 64, 128 and 256 discretization levels (DL). The 64 level was chosen to be the reference DL. Features were calculated based on Co-occurrence (COM), Gray Level Size Zone (GLSZM) and Run-Length (RLM) matrices. Mean Percentage Differences (Δ) of features for discrete levels were determined. Normality distribution of Δ was tested using Kolomogorov - Smirnov test. Bland-Altman test was used to investigate differences between feature values measured on different DL. The mean, standard deviation and upper/lower value limits for each pair of DL were calculated. Interclass Correlation Coefficient (ICC) analysis was performed to examine the reliability of repeated measures within the context of the test re-test format. Results: 3 global and 5 regional features out of 48 features showed distribution not significantly different from a normal one. The reproducible features passed the normality test. Only 5 reproducible results were reliable, ICC range 0.7 – 0.99. Conclusion: Most of the radiomics features tested showed sensitivity to voxel level discretization between (32 – 256). Only 4 GLSZM, 3 COM and 1 RLM showed insensitivity towards mentioned discrete levels.« less
McMahon, Adrienne
2016-01-01
The main objective of the AOAC Stakeholder Panel on Infant Formula and Adult Nutritionals (SPIFAN) project is to establish international consensus methods for infant formula and adult nutritionals, which will benefit intermarket supply and dispute resolution. A collaborative study was conducted on AOAC First Action Method 2012.10 Simultaneous Determination of 13-cis and All-trans Vitamin A Palmitate (Retinyl Palmitate), Vitamin A Acetate (Retinyl Acetate), and Total Vitamin E (α-Tocopherol and D-α-tocopherol acetate) in Infant Formula and Adult Nutritionals by Normal-Phase HPLC. Fifteen laboratories from 11 countries participated in an interlaboratory study to determine 13-cis and all-trans vitamin A palmitate (retinyl palmitate), vitamin A acetate (retinyl acetate), and total vitamin E (α-tocopherol and D-α-tocopherol acetate) in infant formula and adult nutritionals by normal-phase HPLC and all laboratories returned valid data. Eighteen test portions of nine blind duplicates of a variety of infant formula and adult nutritional products were used in the study. The matrixes included milk-based and soy-based hydrolyzed protein as well as a low fat product. Each of the samples was prepared fresh and analyzed in singlicate. As the number of samples exceeded the recommended number to be prepared in a single day, analysis took place over 2 days running 12 samples on day one and 10 samples on day two. The reference standard stock was prepared once and the six-point curve diluted freshly on each day. Results obtained from all 15 laboratories are reported. The RSDR for total vitamin A (palmitate or acetate) ranged from 6.51 to 22.61% and HorRat values ranged from 0.33 to 1.25. The RSDR for total vitamin E (as tocopherol equivalents) ranged from 3.84 to 10.78% and HorRat values ranged from 0.27 to 1.04. Except for an adult low fat matrix which generated reproducibility RSD >40% for some isomers, most SPIFAN matrixes gave results within the acceptance criteria of <16% RSD as stated in the respective Standard Method Performance Requirements.
Transcranial Doppler velocities in a large, healthy population.
Tegeler, Charles H; Crutchfield, Kevin; Katsnelson, Michael; Kim, Jongyeol; Tang, Rong; Passmore Griffin, Leah; Rundek, Tanja; Evans, Greg
2013-07-01
Transcranial Doppler (TCD) ultrasonography has been extensively used in the evaluation and management of patients with cerebrovascular disease since the clinical application was first described in 1982 by Aaslid and colleagues TCD is a painless, safe, and noninvasive diagnostic technique that measures blood flow velocity in various cerebral arteries. Numerous commercially available TCD devices are currently approved for use worldwide, and TCD is recognized to have an established clinical value for a variety of clinical indications and settings. Although many studies have reported normal values, there have been few recently, and none to include a large cohort of healthy subjects across age, race, and gender. As more objective, automated processes are being developed to assist with the performance and interpretation of TCD studies, and with the potential to easily compare results against a reference population, it is important to define stable normal values and variances across age, race, and gender, with clear understanding of variability of the measurements, as well as the yield from various anatomic segments. To define normal TCD values in a healthy population, we enrolled 364 healthy subjects, ages 18-80 years, to have a complete, nonimaging TCD examination. Subjects with known or suspected cerebrovascular disorders, systemic disorders with cerebrovascular effects, as well as those with known hypertension, diabetes, stroke, coronary artery disease, or myocardial infarction, were excluded. Self-reported ethnicity, handedness, BP, and BMI were recorded. A complete TCD examination was performed by a single experienced sonographer, using a single gate nonimaging TCD device, and a standardized protocol to interrogate up to 23 arterial segments. Individual Doppler spectra were saved for each segment, with velocity and pulsatility index (PI) values calculated using the instrument's automated waveform tracking function. Descriptive analysis was done to determine the mean velocities and PI, and all data were analyzed for changes by decade of age, sex race, handedness, BMI, and BP. Among the key intracranial segments, mean blood flow velocities (MBFV) were highest in the MCA and lowest in the PCA across all ages, sexes, and ethnic groups. There was no difference in the MBFVs between left and right side segments of the Circle of Willis, with the exception of the distal M1 (P = .022) and the C1 (P < .0001), both slightly higher on the left. MBFV were higher among women than men in all segments except for the OA. MBFV decreased with advancing age in both men and women, but this was specific to Caucasian subjects. There were lower velocities in the OA for non-Caucasians. The PI was lower in the left VA (P < .0001), and for most segments was lower in women than men. The PI increased with age in all segments for women, but only in some segments for men, and this finding was also specific to Caucasian subjects. The yield of usable data ranged from 99.7% for the VA and BA, to 88.2% for C2. Our study provides normal, reference TCD values for a large cohort of healthy subjects across a wide range of age, sex, and race groups. We observed decreased MBFV and increased PI with aging, and higher MBFV in women. There were few differences in MBFV related to side or ethnicity, but the MFBV and PI changes with age were specific to Caucasians. We provide means and standard deviations of MBFVs across various demographic groups in key intracranial arteries. Such normal TCD values across age, gender, and ethnic groups in healthy subjects represent a useful reference tool for detecting individuals with TCD values outside normal limits and at increased vascular risk. TCD studies in large multiethnic populations are still required to determine differences in brain hemodynamics across various ethnic groups. Copyright © 2012 by the American Society of Neuroimaging.
Belcaro, G; Dugall, M; Ippolito, E; Hu, S; Saggino, A; Feragalli, B
2015-12-01
This 12-month product registry study evaluated the effects of supplementation with French pine bark extract (Pycnogenol(®)) on cognitive function, attention, and mental performance in healthy subjects with high oxidative stress. Healthy subjects (age range 55-70) were screened - within a cardiovascular screening program - for oxidative stress. Out of 150 subjects, high oxidative stress was present in 44; the use of the supplement Pycnogenol(®) was suggested (100 mg/day). These subjects decided to use Pycnogenol(®) and accepted to be evaluated by assessing cognitive functions. A group of subjects with comparable oxidative stress was followed as a reference. IQ Code (Informant Questionnaire on Cognitive Decline in the Elderly), daily tasks, cognitive function, oxidative stress and the short Blessed tests (SBT) were used (in defined scales) to evaluate cognitive functions (COFU). As for the IQ Code, at 12 months there was a significantlty total lower score in Pycnogenol(®) patients and also a lower value (P<0.05) for 14 out of 16 items in the questionnaire. Daily tasks: all items were improved (P<0.05) with supplementation in comparison with controls. The improvement was seen for all 12 items (P<0.05) with the supplement. Cognitive function values (visual scale line) indicated a significant improvement (P<0.05) in all elements present in the questionnaire with the 12-month supplementation (no significant variations in controls). Oxidative stress was comparable in both groups at inclusion. It was significantly decreased with Pycnogenol(®) (-28.07%; P<0.05) at 12 months; there was no decrease in controls. The short blessed test (SBT) value was significantly increased in controls (P<0.05); but significantly decreased in the Pycnogenol(®) group (P<0.05). Values for supplemented patients at 12 months were almost within the normal range (21 out or 38 were below the normal value of 4). Tolerability and compliance for Pycnogenol(®) were optimal with >97% of the doses of the supplement correctly used. No side effects were observed, recorded or described. Pycnogenol(®) supplementation for 12 months appears to improve cognitive function and oxidative stress in normal subjects between 55 and 70 years of age.
Short residence time coal liquefaction process including catalytic hydrogenation
Anderson, R.P.; Schmalzer, D.K.; Wright, C.H.
1982-05-18
Normally solid dissolved coal product and a distillate liquid product are produced by continuously passing a feed slurry comprising raw feed coal and a recycle solvent oil and/or slurry together with hydrogen to a preheating-reaction zone, the hydrogen pressure in the preheating-reaction zone being at least 1,500 psig (105 kg/cm[sup 2]), reacting the slurry in the preheating-reaction zone at a temperature in the range of between about 455 and about 500 C to dissolve the coal to form normally liquid coal and normally solid dissolved coal. A total slurry residence time is maintained in the reaction zone ranging from a finite value from about 0 to about 0.2 hour, and reaction effluent is continuously and directly contacted with a quenching fluid to substantially immediately reduce the temperature of the reaction effluent to below 425 C to substantially inhibit polymerization so that the yield of insoluble organic matter comprises less than 9 weight percent of said feed coal on a moisture-free basis. The reaction is performed under conditions of temperature, hydrogen pressure and residence time such that the quantity of distillate liquid boiling within the range C[sub 5]-454 C is an amount at least equal to that obtainable by performing the process under the same condition except for a longer total slurry residence time, e.g., 0.3 hour. Solvent boiling range liquid is separated from the reaction effluent and recycled as process solvent. The amount of solvent boiling range liquid is sufficient to provide at least 80 weight percent of that required to maintain the process in overall solvent balance. 6 figs.
Short residence time coal liquefaction process including catalytic hydrogenation
Anderson, Raymond P.; Schmalzer, David K.; Wright, Charles H.
1982-05-18
Normally solid dissolved coal product and a distillate liquid product are produced by continuously passing a feed slurry comprising raw feed coal and a recycle solvent oil and/or slurry together with hydrogen to a preheating-reaction zone (26, alone, or 26 together with 42), the hydrogen pressure in the preheating-reaction zone being at least 1500 psig (105 kg/cm.sup.2), reacting the slurry in the preheating-reaction zone (26, or 26 with 42) at a temperature in the range of between about 455.degree. and about 500.degree. C. to dissolve the coal to form normally liquid coal and normally solid dissolved coal. A total slurry residence time is maintained in the reaction zone ranging from a finite value from about 0 to about 0.2 hour, and reaction effluent is continuously and directly contacted with a quenching fluid (40, 68) to substantially immediately reduce the temperature of the reaction effluent to below 425.degree. C. to substantially inhibit polymerization so that the yield of insoluble organic matter comprises less than 9 weight percent of said feed coal on a moisture-free basis. The reaction is performed under conditions of temperature, hydrogen pressure and residence time such that the quantity of distillate liquid boiling within the range C.sub.5 -454.degree. C. is an amount at least equal to that obtainable by performing the process under the same condition except for a longer total slurry residence time, e.g., 0.3 hour. Solvent boiling range liquid is separated from the reaction effluent (83) and recycled as process solvent (16). The amount of solvent boiling range liquid is sufficient to provide at least 80 weight percent of that required to maintain the process in overall solvent balance.
Lovely, C J; Pittman, J M; Leslie, A J
2007-09-01
Wild Nile crocodiles (Crocodylus niloticus) of various size classes were captured in the Okavango Delta, Botswana. Blood was collected from the post occipital sinus and used for the determination of a wide range of haematological and biochemical parameters. These values were compared between the sexes and between 3 size classes. The values were also compared with the limited data available from farmed Nile crocodiles, as well as from other wild Nile crocodiles. The Okavango crocodiles were comparatively anaemic, and had comparatively low total protein and blood glucose levels. There was a high prevalence of Hepatozoon pettiti infection, however, there was no significant difference in haematological values between the infected and uninfected crocodiles. The values reported here will be useful in diagnostic investigations in both zoo and farmed Nile crocodiles.
Calculated and measured [Ca(2+)] in buffers used to calibrate Ca(2+) macroelectrodes.
McGuigan, John A S; Stumpff, Friederike
2013-05-01
The ionized concentration of calcium in physiological buffers ([Ca(2+)]) is normally calculated using either tabulated constants or software programs. To investigate the accuracy of such calculations, the [Ca(2+)] in EGTA [ethylene glycol-bis(β-aminoethylether)-N,N,N|,N|-tetraacetic acid], BAPTA [1,2-bis(o-aminophenoxy) ethane-N,N,N|,N|-tetraacetic acid], HEDTA [N-(2-hydroxyethyl)-ethylenediamine-N,N|,N|-triacetic acid], and NTA [N,N-bis(carboxymethyl)glycine] buffers was estimated using the ligand optimization method, and these measured values were compared with calculated values. All measurements overlapped in the pCa range of 3.51 (NTA) to 8.12 (EGTA). In all four buffer solutions, there was no correlation between measured and calculated values; the calculated values differed among themselves by factors varying from 1.3 (NTA) to 6.9 (EGTA). Independent measurements of EGTA purity and the apparent dissociation constants for HEDTA and NTA were not significantly different from the values estimated by the ligand optimization method, further substantiating the method. Using two calibration solutions of pCa 2.0 and 3.01 and seven buffers in the pCa range of 4.0-7.5, calibration of a Ca(2+) electrode over the pCa range of 2.0-7.5 became a routine procedure. It is proposed that such Ca(2+) calibration/buffer solutions be internationally defined and made commercially available to allow the precise measurement of [Ca(2+)] in biology. Copyright © 2013 Elsevier Inc. All rights reserved.
Resource allocation in academic health centers: creating common metrics.
Joiner, Keith A; Castellanos, Nathan; Wartman, Steven A
2011-09-01
Optimizing resource allocation is essential for effective academic health center (AHC) management, yet guidelines and principles for doing so in the research and educational arenas remain limited. To address this issue, the authors analyzed responses to the 2007-2008 Association of Academic Health Centers census using ratio analysis. The concept was to normalize data from an individual institution to that same institution, by creating a ratio of two separate values from the institution (e.g., total faculty FTEs/total FTEs). The ratios were then compared across institutions. Generally, this strategy minimizes the effect of institution size on the responses, size being the predominant limitation of using absolute values for developing meaningful metrics. In so doing, ratio analysis provides a range of responses that can be displayed in graphical form to determine the range and distribution of values. The data can then be readily scrutinized to determine where any given institution falls within the distribution. Staffing ratios and operating ratios from up to 54 institutions are reported. For ratios including faculty numbers in the numerator or denominator, the range of values is wide and minimally discriminatory, reflecting heterogeneity across institutions in faculty definitions. Values for financial ratios, in particular total payroll expense/total operating expense, are more tightly clustered, reflecting in part the use of units with a uniform definition (i.e., dollars), and emphasizing the utility of such ratios in decision guidelines. The authors describe how to apply these insights to develop metrics for resource allocation in the research and educational arenas.
Presumed primary thiamine deficiency in a young African lion (Panthera leo).
DiGesualdo, Cynthia L; Hoover, John P; Lorenz, Michael D
2005-09-01
A 1-yr-old intact male African lion (Panthera leo) fed only beef muscle meat was evaluated for episodes of hypermetric ataxia, generalized weakness and tonic-clonic front limb movements. A hemogram, biochemical profile, blood lead, electrocardiogram, survey radiographs, and brain computed tomography were normal. Cerebral spinal fluid analyses suggested mild inflammation. Acetylcholine receptor antibody and serologic tests for all infectious agents tested were negative. Clinical signs resolved completely 9 days after instituting oral thiamine (3 mg/kg/day) and a completely nutritional diet. This lion's pretreatment thiamine blood value (11 nmol/L) was markedly lower than that of a healthy lion (191 nmol/L) and a proposed reference range for adult African lions (160-350 nmol/L). The lion remained clinically normal 2 yr later when his blood thiamine value was 340 nmol/L. African lions can develop clinical primary thiamine deficiency and may respond favorably when thiamine treatment and adequate diet are instituted prior to irreversible neuronal necrosis.
NASA Astrophysics Data System (ADS)
Majidi, Leyla; Zare, Moslem; Asgari, Reza
2018-06-01
The unusual features of the charge and spin transport characteristics are investigated in new two-dimensional heterostructures. Intraband specular Andreev reflection is realized in a topological insulator thin film normal/superconducting junction in the presence of a gate electric field. Perfect specular electron-hole conversion is shown for different excitation energy values in a wide experimentally available range of the electric field and also for all angles of incidence when the excitation energy has a particular value. It is further demonstrated that the transmission probabilities of the incoming electrons from different spin subbands to the monolayer phosphorene ferromagnetic/normal/ferromagnetic (F/N/F) hybrid structure have different behavior with the angle of incidence and perfect transmission occurs at defined angles of incidence to the proposed structure with different length of the N region, and different alignments of magnetization vectors. Moreover, the sign change of the spin-current density is demonstrated by tuning the chemical potential and exchange field of the F region.
Protein electrophoresis as a diagnostic and prognostic tool in raptor medicine.
Tatum, L M; Zaias, J; Mealey, B K; Cray, C; Bossart, G D
2000-12-01
Plasma proteins of 139 healthy adult birds of prey from 10 species were separated by electrophoresis to characterize and document normal reference ranges and species-specific electrophoretic patternsand to evaluate the value of this technique for health screening, disease diagnosis, and prognostic indication. Species studied included bald eagle (Haliaeetus leucocephalus), red-tailed hawk (Buteo jamaicensis), barn owl (Tyto alba), great horned owl (Bubo virginianus), turkey vulture (Cathartes aura), Harris' hawk (Parabuteo unicinctus), Stellar's sea eagle (Haliaeetus pelagicus), barred owl (Strix varia), screech owl (Otus asio), and black vulture (Coragyps atratus). Several clinical cases show the diagnostic/therapeutic value of protein electrophoresis in raptors. This study establishes species-specific reference ranges for several birds of prey and discusses the benefit of electrophoresis as a diagnostic technique in health screens, as a diagnostic aid in conjunction with other tests, and as a prognostic indicator in clinical evaluation of raptors.
A new comprehensive index for drought monitoring with TM data
NASA Astrophysics Data System (ADS)
Wang, Yuanyuan
2017-10-01
Drought is one of the most important and frequent natural hazards to agriculture production in North China Plain. To improve agriculture water management, accurate drought monitoring information is needed. This study proposed a method for comprehensive drought monitoring by combining a meteorological index and three satellite drought indices of TM data together. SPI (Standard Precipitation Index), the meteorological drought index, is used to measure precipitation deficiency. Three satellite drought indices (Temperature Vegetation Drought Index, Land Surface Water Index, Modified Perpendicular Drought Index) are used to evaluate agricultural drought risk by exploring data from various channels (VIS, NIR, SWIR, TIR). Considering disparities in data ranges of different drought indices, normalization is implemented before combination. First, SPI is normalized to 0 — 100 given that its normal range is -4 - +4. Then, the three satellite drought indices are normalized to 0 - 100 according to the maximum and minimum values in the image, and aggregated using weighted average method (the result is denoted as ADI, Aggregated drought index). Finally, weighed geometric mean of SPI and ADI are calculated (the result is denoted as DIcombined). A case study in North China plain using three TM images acquired during April-May 2007 show that the method proposed in this study is effective. In spatial domain, DIcombined demonstrates dramatically more details than SPI; in temporal domain, DIcombined shows more reasonable drought development trajectory than satellite indices that are derived from independent TM images.
Preliminary Results of Stability and Control Investigation of the Bell X-5 Research Airplane
NASA Technical Reports Server (NTRS)
Finch, Thomas W; Briggs, Donald W
1953-01-01
During the acceptance tests of the Bell X-5 airplane, measurements of the static stability and control characteristics and horizontal-tail loads were obtained by the NACA High-Speed Flight Research Station. The results of the stability and control measurements are presented in this paper. A change in sweep angle between 20 deg and 59 deg had a minor effect on the longitudinal trim, with a maximum change of about 2.5 deg in elevator deflection being required at a Mach number near 0.85; however, sweeping the wings produced a total stick-force change of about 40 pounds. At low Mach numbers there was a rapid increase in stability at high normal-force coefficients for both 20 0 and 1100 sweepback, whereas a condition of neutral stability existed for 58 0 sweepback at high normal-force coefficients. At Mach numbers near 0.8 there was an instability at normal-force coefficients above 0.5 for all sweep angles tested. In the low normal-force-coefficient range a high degree of stability resulted in high stick forces which limited the maximum load factors attainable in the demonstration flights to values under 5g for all sweep angles at a Mach number near 0.8 and an altitude of 12,000 feet. The aileron effectiveness at 200 sweepback was found to be low over the Mach number range tested.
Zimmer, Bernd; Sino, Hiba
2018-03-19
To analyze common values of bracket torque (Andrews, Roth, MBT, Ricketts) for their validity in achieving incisor inclinations that are considered normal by different cephalometric standards. Using the equations developed in part 1 (eU1 (BOP) = 90° - BT (U1) - TCA (U1) + α 1 - α 2 and eL1 (BOP) = 90° - BT (L1) - TCA (L1) + β 1 - β 2 ) (abbreviations see part 1) and the mean values (± SD) obtained as statistical measures in parts 1 and 2 of the study (α 1 and β 1 [1.7° ± 0.7°], α 2 [3.6° ± 0.3°], β 2 [3.2° ± 0.4°], TCA (U1) [24.6° ± 3.6°] and TCA (L1) [22.9° ± 4.3°]) expected (= theoretically anticipated) values were calculated for upper and lower incisors (U1 and L1) and compared to targeted (= cephalometric norm) values. For U1, there was no overlapping between the ranges of expected and targeted values, as the lowest targeted value of (58.3°; Ricketts) was higher than the highest expected value (56.5°; Andrews) relative to the bisected occlusal plane (BOP). Thus all of these torque systems will aim for flatter inclinations than prescribed by any of the norm values. Depending on target values, the various bracket systems fell short by 1.8-5.5° (Andrews), 6.8-10.5° (Roth), 11.8-15.5° (MBT), or 16.8-20.5° (Ricketts). For L1, there was good agreement of the MBT system with the Ricketts and Björk target values (Δ0.1° and Δ-0.8°, respectively), and both the Roth and Ricketts systems came close to the Bergen target value (both Δ2.3°). Depending on target values, the ranges of deviation for L1 were 6.3-13.2° for Andrews (Class II prescription), 2.3°-9.2° for Roth, -3.7 to -3.2° for MBT, and 2.3-9.2° for Ricketts. Common values of upper incisor bracket torque do not have acceptable validity in achieving normal incisor inclinations. A careful selection of lower bracket torque may provide satisfactory matching with some of the targeted norm values.
Dynamic Divisive Normalization Predicts Time-Varying Value Coding in Decision-Related Circuits
LoFaro, Thomas; Webb, Ryan; Glimcher, Paul W.
2014-01-01
Normalization is a widespread neural computation, mediating divisive gain control in sensory processing and implementing a context-dependent value code in decision-related frontal and parietal cortices. Although decision-making is a dynamic process with complex temporal characteristics, most models of normalization are time-independent and little is known about the dynamic interaction of normalization and choice. Here, we show that a simple differential equation model of normalization explains the characteristic phasic-sustained pattern of cortical decision activity and predicts specific normalization dynamics: value coding during initial transients, time-varying value modulation, and delayed onset of contextual information. Empirically, we observe these predicted dynamics in saccade-related neurons in monkey lateral intraparietal cortex. Furthermore, such models naturally incorporate a time-weighted average of past activity, implementing an intrinsic reference-dependence in value coding. These results suggest that a single network mechanism can explain both transient and sustained decision activity, emphasizing the importance of a dynamic view of normalization in neural coding. PMID:25429145
Solar-cycle dependence of a model turbulence spectrum using IMP and ACE observations over 38 years
NASA Astrophysics Data System (ADS)
Burger, R. A.; Nel, A. E.; Engelbrecht, N. E.
2014-12-01
Ab initio modulation models require a number of turbulence quantities as input for any reasonable diffusion tensor. While turbulence transport models describe the radial evolution of such quantities, they in turn require observations in the inner heliosphere as input values. So far we have concentrated on solar minimum conditions (e.g. Engelbrecht and Burger 2013, ApJ), but are now looking at long-term modulation which requires turbulence data over at a least a solar magnetic cycle. As a start we analyzed 1-minute resolution data for the N-component of the magnetic field, from 1974 to 2012, covering about two solar magnetic cycles (initially using IMP and then ACE data). We assume a very simple three-stage power-law frequency spectrum, calculate the integral from the highest to the lowest frequency, and fit it to variances calculated with lags from 5 minutes to 80 hours. From the fit we then obtain not only the asymptotic variance at large lags, but also the spectral index of the inertial and the energy, as well as the breakpoint between the inertial and energy range (bendover scale) and between the energy and cutoff range (cutoff scale). All values given here are preliminary. The cutoff range is a constraint imposed in order to ensure a finite energy density; the spectrum is forced to be either flat or to decrease with decreasing frequency in this range. Given that cosmic rays sample magnetic fluctuations over long periods in their transport through the heliosphere, we average the spectra over at least 27 days. We find that the variance of the N-component has a clear solar cycle dependence, with smaller values (~6 nT2) during solar minimum and larger during solar maximum periods (~17 nT2), well correlated with the magnetic field magnitude (e.g. Smith et al. 2006, ApJ). Whereas the inertial range spectral index (-1.65 ± 0.06) does not show a significant solar cycle variation, the energy range index (-1.1 ± 0.3) seems to be anti-correlated with the variance (Bieber et al. 1993, JGR); both indices show close to normal distributions. In contrast, the variance (e.g. Burlaga and Ness, 1998, JGR), and both the bendover scale (see Ruiz et al. 2014, Solar Physics) and cutoff scale appear to be log-normal distributed.
Comparison of diffusion-weighted MRI acquisition techniques for normal pancreas at 3.0 Tesla.
Yao, Xiu-Zhong; Kuang, Tiantao; Wu, Li; Feng, Hao; Liu, Hao; Cheng, Wei-Zhong; Rao, Sheng-Xiang; Wang, He; Zeng, Meng-Su
2014-01-01
We aimed to optimize diffusion-weighted imaging (DWI) acquisitions for normal pancreas at 3.0 Tesla. Thirty healthy volunteers were examined using four DWI acquisition techniques with b values of 0 and 600 s/mm2 at 3.0 Tesla, including breath-hold DWI, respiratory-triggered DWI, respiratory-triggered DWI with inversion recovery (IR), and free-breathing DWI with IR. Artifacts, signal-to-noise ratio (SNR) and apparent diffusion coefficient (ADC) of normal pancreas were statistically evaluated among different DWI acquisitions. Statistical differences were noticed in artifacts, SNR, and ADC values of normal pancreas among different DWI acquisitions by ANOVA (P <0.001). Normal pancreas imaging had the lowest artifact in respiratory-triggered DWI with IR, the highest SNR in respiratory-triggered DWI, and the highest ADC value in free-breathing DWI with IR. The head, body, and tail of normal pancreas had statistically different ADC values on each DWI acquisition by ANOVA (P < 0.05). The highest image quality for normal pancreas was obtained using respiratory-triggered DWI with IR. Normal pancreas displayed inhomogeneous ADC values along the head, body, and tail structures.
28 CFR Appendix A to Part 79 - FVC and FEV-1 Lower Limits of Normal Values
Code of Federal Regulations, 2011 CFR
2011-07-01
... 28 Judicial Administration 2 2011-07-01 2011-07-01 false FVC and FEV-1 Lower Limits of Normal... RADIATION EXPOSURE COMPENSATION ACT Pt. 79, App. A Appendix A to Part 79—FVC and FEV-1 Lower Limits of Normal Values Table 1—Caucasian Males FVC Lower Limit of Normal Values, Hankinson, et al. (1999...
Water-resources investigations in Wisconsin, 2004
Bruce, Jennifer L.; Greenwood, Michelle M.; Jones, Susan Z.
2004-01-01
The statewide average precipitation for the 2003 water year was 27.42 inches, which was 5.22 inches less than the normal annual precipitation of 32.64 inches for water years 1971–2000. Average precipitation values affecting streamflow conditions ranged from 67 percent in southeast Wisconsin to 99 percent in northeast Wisconsin with a statewide average of 84 percent (summary tables provided by Ed Hopkins, State Climatology Office, University of Wisconsin, Madison, written commun., 2004).
Shaw, Mark; Meda, Venkatesh; Tabil, Lope; Opoku, Anthony
2007-01-01
Heat sensitive properties (aromatic, medicinal, color) provide herbs and spices with their high market value. In order to prevent extreme loss of heat sensitive properties when drying herbs, they are normally dried at low temperatures for longer periods of time to preserve these sensory properties. High energy consumption often results from drying herbs over a long period. Coriander (Coriandrum sativum L., Umbelliferae) was dehydrated in two different drying units (thin layer convection and microwave dryers) in order to compare the drying and final product quality (color) characteristics. Microwave drying of the coriander foliage was faster than convective drying. The entire drying process took place in the falling rate period for both microwave and convective dried samples. The drying rate for the microwave dried samples ranged from 42.3 to 48.2% db/min and that of the convective dried samples ranged from 7.1 to 12.5% db/min. The fresh sample color had the lowest L value at 26.83 with higher L values for all dried samples. The results show that convective thin layer dried coriander samples exhibited a significantly greater color change than microwave dried coriander samples. The color change index values for the microwave dried samples ranged from 2.67 to 3.27 and that of the convective dried samples varied from 4.59 to 6.58.
Validation of serum free light chain reference ranges in primary care.
Galvani, Luca; Flanagan, Jane; Sargazi, Mansour; Neithercut, William D
2016-05-01
The demand for measurement of serum immunoglobulin free kappa (κ) and lambda (λ) light chains has increased. The κ:λ ratio is used to assist in diagnosis/monitoring of plasma cell disorders. The binding site reference range for serum-free light chain κ:λ ratios of 0.26-1.65 was derived from healthy volunteers. Subsequently, a reference range of 0.37-3.1 for patients with chronic kidney disease has been proposed. Elevated free light chain concentrations and borderline raised free light chain ratios also may be found in polyclonal gammopathies and with other non-renal illnesses. This assessment was conducted to validate the established free light chain reference ranges in individuals from primary care. A total of 130 samples were identified from routine blood samples collected in primary care for routine biochemistry testing and estimated glomerular filtration rate calculation. The median and range of κ:λ ratios found in each estimated glomerular filtration rate group used for chronic kidney disease classification were higher than previously described. This was the case for individuals with normal or essentially normal renal function with estimated glomerular filtration rates>90, (0.58-1.76) and estimated glomerular filtration rate of 60-90 mL/min/1.73 m(2), (0.71-1.93). Individuals with estimated glomerular filtration rate 15-30, (0.72-4.50) and estimated glomerular filtration rate <15 ml/min/1.73 m(2) (0.71-4.95) also had higher values when compared to the current renal reference range of 0.37-3.10. Elevation of free light chain-κ:λ ratios may occur in the absence of a reduced renal function shown by a normal estimated glomerular filtration rate and in the presence of reduced renal function by estimated glomerular filtration rate when comparing results with the established reference ranges. Explanations include choice of analytical systems or the presence of other concurrent non-plasma cell illness. © The Author(s) 2016.
Controlled short residence time coal liquefaction process
Anderson, Raymond P.; Schmalzer, David K.; Wright, Charles H.
1982-05-04
Normally solid dissolved coal product and a distillate liquid product are produced by continuously passing a feed slurry comprising raw feed coal and a recycle solvent oil and/or slurry together with hydrogen to a preheating-reaction zone (26, alone, or 26 together with 42), the hydrogen pressure in the preheating-reaction zone being at least 1500 psig (105 kg/cm.sup.2), reacting the slurry in the preheating-reaction zone (26, or 26 with 42) at a temperature in the range of between about 455.degree. and about 500.degree. C. to dissolve the coal to form normally liquid coal and normally solid dissolved coal. A total slurry residence time is maintained in the reaction zone ranging from a finite value from about 0 to about 0.2 hour, and reaction effluent is continuously and directly contacted with a quenching fluid (40, 68) to substantially immediately reduce the temperature of the reaction effluent to below 425.degree. C. to substantially inhibit polymerization so that the yield of insoluble organic matter comprises less than 9 weight percent of said feed coal on a moisture-free basis. The reaction is performed under conditions of temperature, hydrogen pressure and residence time such that the quantity of distillate liquid boiling within the range C.sub.5 -455.degree. C. is an amount at least equal to that obtainable by performing the process under the same conditions except for a longer total slurry residence time, e.g., 0.3 hour. Solvent boiling range liquid is separated from the reaction effluent and recycled as process solvent.
Kannan, Subramanian; Mahadevan, Shriraam; Sigamani, Alben
2018-01-01
Small cross-sectional studies are published on the trimester-specific normal ranges of thyrotropin and thyroxine levels in Indian women from various parts of the country. We sought to review the published literature on thyroid function tests in normal pregnant Indian women to see if the pooled data from various studies can define normative data and hypothyroidism in pregnancy. We retrieved 56 studies from online databases with detailed search using multiple search terms. Unanimously eight studies were finalized. Data of 2703 pregnant women (age 16-45 years; 966 were in the first trimester, 1072 in their second trimester, and 1037 women in their third trimester) were analyzed. All eight studies included singleton pregnancies from the northern and eastern part of India with seven studies being cross-sectional in nature. The exclusion criteria in all studies included those with historical/clinical evidence of thyroid dysfunction, those with family history of thyroid dysfunction, infertility and those with history of recurrent miscarriages (usually >3). Ultrasound evidence of thyroid disease, urinary iodine assessment, and thyroid antibodies were included as additional exclusion criteria in two, three, and four studies, respectively. None of the studies included the outcome of pregnancy as part of follow-up. As part of the pooled data analysis, the 5 th -95 th centile values of normal TSH extended from 0.09 to 6.65 IU/mL in the first trimester, 0.39-6.61 IU/mL in the second trimester, and 0.70-5.18 IU/mL in the third trimester. The FT4 levels (5 th -95 th centile values) extended from 8.24 to 25.74 pmol/L in the first trimester, 6.82-26.0 pmol/L, and 5.18-25.61 pmol/L in the third trimester. With due limitations imposed by the quality of the available studies, the current review suggests that upper normal limit of TSH values can extend up to 5-6 IU/mL in pregnancy.
Serum C-reactive protein in patients undergoing elective shoulder arthroplasty. Prospective study.
Torrens, Carlos; Santana, Fernando; Marí, Raquel; Puig, Lluis; Alier, Albert
2017-09-01
The objective of the study was to determine the normalization curve of the serum C-reactive protein (CRP) in elective shoulder arthroplasty. A prospective study including 58 consecutive patients who had undergone elective shoulder arthroplasty. Forty-one patients had received a Reverse Shoulder Arthroplasty, 13 a Total Shoulder Arthroplasty and 4 a Hemiarthroplasty. Based on a pilot study, blood samples to determine CRP values were obtained at baseline (1 h before surgery), on the 1st, 2nd, 6th, 8th and 14th postoperative days. All the patients included presented no postoperative complications during inpatient stay or any re-admission during the three months after surgery. Mean CRP values showed a rapid increase on the 1st postoperative day (7-fold higher than the baseline in cuff tear arthropathy, 11-fold higher in primary osteoarthritis, 1-fold higher in acute fracture) and reached a peak on the 2nd postoperative day (14-fold higher than the baseline in cuff tear arthropathy, 24-fold higher in primary osteoarthritis and 2-fold higher in acute fracture). After the 2nd postoperative day CRP values began to slowly decrease reaching the normal range in the 14th postoperative day. Serum CRP levels after elective shoulder arthroplasty rapidly increase to reach a maximum peak after the 2nd surgery day and then slowly decrease to return to normality on the 14th day. Knowing the normalization curve of CRP can be a helpful tool to help in the diagnosis of acute infections in elective shoulder arthroplasty. Copyright © 2017 The Japanese Orthopaedic Association. Published by Elsevier B.V. All rights reserved.
The largest Lyapunov exponent of gait in young and elderly individuals: A systematic review.
Mehdizadeh, Sina
2018-02-01
The largest Lyapunov exponent (LyE) is an accepted method to quantify gait stability in young and old adults. However, a range of LyE values has been reported in the literature for healthy young and elderly adults in normal walking. Therefore, it has been impractical to use the LyE as a clinical measure of gait stability. The aims of this systematic review were to summarize different methodological approaches of quantifying LyE, as well as to classify LyE values of different body segments and joints in young and elderly individuals during normal walking. The Pubmed, Ovid Medline, Scopus and ISI Web of Knowledge databases were searched using keywords related to gait, stability, variability, and LyE. Only English language articles using the Lyapunov exponent to quantify the stability of healthy normal young and old subjects walking on a level surface were considered. 102 papers were included for full-text review and data extraction. Data associated with the walking surface, data recording method, sampling rate, walking speed, body segments and joints, number of strides/steps, variable type, filtering, time-normalizing, state space dimension, time delay, LyE algorithm, and the LyE values were extracted. The disparity in implementation and calculation of the LyE was from, (i) experiment design, (ii) data pre-processing, and (iii) LyE calculation method. For practical implementation of LyE as a measure of gait stability in clinical settings, a standard and universally accepted approach of calculating LyE is required. Therefore, future studies should look for a standard and generalized procedure to apply and calculate LyE. Copyright © 2017 Elsevier B.V. All rights reserved.
Been, Ella; Kalichman, Leonid
2014-01-01
Lumbar lordosis is a key postural component that has interested both clinicians and researchers for many years. Despite its wide use in assessing postural abnormalities, there remain many unanswered questions regarding lumbar lordosis measurements. Therefore, in this article we reviewed different factors associated with the lordosis angle based on existing literature and determined normal values of lordosis. We reviewed more than 120 articles that measure and describe the different factors associated with the lumbar lordosis angle. Because of a variety of factors influencing the evaluation of lumbar lordosis such as how to position the patient and the number of vertebrae included in the calculation, we recommend establishing a uniform method of evaluating the lordosis angle. Based on our review, it seems that the optimal position for radiologic measurement of lordosis is standing with arms supported while shoulders are flexed at a 30° angle. There is evidence that many factors, such as age, gender, body mass index, ethnicity, and sport, may affect the lordosis angle, making it difficult to determine uniform normal values. Normal lordosis should be determined based on the specific characteristics of each individual; we therefore presented normal lordosis values for different groups/populations. There is also evidence that the lumbar lordosis angle is positively and significantly associated with spondylolysis and isthmic spondylolisthesis. However, no association has been found with other spinal degenerative features. Inconclusive evidence exists for association between lordosis and low back pain. Additional studies are needed to evaluate these associations. The optimal lordotic range remains unknown and may be related to a variety of individual factors such as weight, activity, muscular strength, and flexibility of the spine and lower extremities. Copyright © 2014 Elsevier Inc. All rights reserved.
Elnekave, Eldad; Belenky, Eugenia; Van der Veer, Lindsley
2015-01-01
A 54-year-old woman presented with a six-month history of episodic confusion and progressive ataxia. A comprehensive metabolic panel was notable for elevated values of alkaline phosphatase (161 U/L), total bilirubin (1.5 mg/dL), and serum ammonia of 300 umol/L (normal range 9–47). Hepatitis panel, relevant serological tests, tumor markers (CA-19-9, CEA), and urea cycle enzyme studies were unrevealing. Lactulose and rifaximin therapy failed to normalize serum ammonia levels. Imaging revealed a structural vascular abnormality communicating between an enlarged inferior mesenteric vein and the left renal vein, measuring 16 mm in greatest diameter. The diagnosis of congenital extrahepatic portosystemic shunt was made and endovascular shunt closure was performed using a 22 mm Amplatzer II vascular plug. Within a day, serum ammonia levels normalized. Lactulose and rifaximin were discontinued, and confusion and ataxia resolved. PMID:26199783
S-Wave Normal Mode Propagation in Aluminum Cylinders
Lee, Myung W.; Waite, William F.
2010-01-01
Large amplitude waveform features have been identified in pulse-transmission shear-wave measurements through cylinders that are long relative to the acoustic wavelength. The arrival times and amplitudes of these features do not follow the predicted behavior of well-known bar waves, but instead they appear to propagate with group velocities that increase as the waveform feature's dominant frequency increases. To identify these anomalous features, the wave equation is solved in a cylindrical coordinate system using an infinitely long cylinder with a free surface boundary condition. The solution indicates that large amplitude normal-mode propagations exist. Using the high-frequency approximation of the Bessel function, an approximate dispersion relation is derived. The predicted amplitude and group velocities using the approximate dispersion relation qualitatively agree with measured values at high frequencies, but the exact dispersion relation should be used to analyze normal modes for full ranges of frequency of interest, particularly at lower frequencies.
19 CFR 351.408 - Calculation of normal value of merchandise from nonmarket economy countries.
Code of Federal Regulations, 2013 CFR
2013-04-01
... nonmarket economy countries. 351.408 Section 351.408 Customs Duties INTERNATIONAL TRADE ADMINISTRATION... economy countries. (a) Introduction. In identifying dumping from a nonmarket economy country, the Secretary normally will calculate normal value by valuing the nonmarket economy producers' factors of...
19 CFR 351.408 - Calculation of normal value of merchandise from nonmarket economy countries.
Code of Federal Regulations, 2011 CFR
2011-04-01
... nonmarket economy countries. 351.408 Section 351.408 Customs Duties INTERNATIONAL TRADE ADMINISTRATION... economy countries. (a) Introduction. In identifying dumping from a nonmarket economy country, the Secretary normally will calculate normal value by valuing the nonmarket economy producers' factors of...
19 CFR 351.408 - Calculation of normal value of merchandise from nonmarket economy countries.
Code of Federal Regulations, 2012 CFR
2012-04-01
... nonmarket economy countries. 351.408 Section 351.408 Customs Duties INTERNATIONAL TRADE ADMINISTRATION... economy countries. (a) Introduction. In identifying dumping from a nonmarket economy country, the Secretary normally will calculate normal value by valuing the nonmarket economy producers' factors of...
19 CFR 351.408 - Calculation of normal value of merchandise from nonmarket economy countries.
Code of Federal Regulations, 2014 CFR
2014-04-01
... nonmarket economy countries. 351.408 Section 351.408 Customs Duties INTERNATIONAL TRADE ADMINISTRATION... economy countries. (a) Introduction. In identifying dumping from a nonmarket economy country, the Secretary normally will calculate normal value by valuing the nonmarket economy producers' factors of...
Normal distribution pattern and physiological variants of 68Ga-PSMA-11 PET/CT imaging.
Demirci, Emre; Sahin, Onur Erdem; Ocak, Meltem; Akovali, Burak; Nematyazar, Jamal; Kabasakal, Levent
2016-11-01
Ga-PSMA-11 is a novel PET tracer suggested to be used for imaging of advanced prostate cancer. In this study, we aimed to present a detailed biodistribution of Ga-PSMA-11, including physiological and benign variants of prostate-specific membrane antigen (PSMA) imaging. We carried out a retrospective analysis of 40 patients who underwent PSMA PET/computed tomography (CT) imaging and who had no evidence of residual or metastatic disease on the scans. In addition, 16 patients who underwent PSMA PET/CT imaging with any indication other than prostate cancer were included in the study to evaluate physiological uptake in the normal prostate gland. The median, minimum-maximum, and mean standardized uptake value (SUV) values were calculated for visceral organs, bone marrow and lymph nodes, and mucosal areas. Any physiological variants or benign lesions with Ga-PSMA-11 were also noted. Ga-PSMA-11 uptake was noted in the kidneys, parotid and submandibular glands, duodenum, small intestines, spleen, liver, and lacrimal glands, and mucosal uptake in the nasopharynx, vocal cords, pancreas, stomach, mediastinal blood pool, thyroid gland, adrenal gland, rectum, vertebral bone marrow, and testes. Celiac ganglia showed slight Ga-PSMA-11 uptake in 24 of 40 patients without the presence of any other pathologic lymph nodes in abdominal and pelvic areas. Variable uptake of Ga-PSMA-11 was observed in calcified choroid plexus, a thyroid nodule, an adrenal nodule, axillary lymph nodes and celiac ganglia, occasional osteophytes, and gallbladder. The patient group with PSMA PET/CT for indications other than prostate cancer (n=16) showed a slight radiotracer uptake in normal prostate gland (SUVmax: 5.5±1.6, range: 3.5-8.3). This study shows normal distribution pattern, range of SUVs, and physiological variants of Ga-PSMA-11. In addition, several potential pitfalls were documented to prevent misinterpretations of the scan.
Measurement of the n-p elastic scattering angular distribution at E{sub n}=14.9 MeV
DOE Office of Scientific and Technical Information (OSTI.GOV)
Boukharouba, N.; Bateman, F. B.; Carlson, A. D.
2010-07-15
The relative differential cross section for the elastic scattering of neutrons by protons was measured at an incident neutron energy E{sub n}=14.9 MeV and for center-of-mass scattering angles ranging from about 60 deg. to 180 deg. Angular distribution values were obtained from the normalization of the integrated data to the n-p total elastic scattering cross section. Comparisons of the normalized data to the predictions of the Arndt et al. phase-shift analysis, those of the Nijmegen group, and with the ENDF/B-VII.0 evaluation are sensitive to the value of the total elastic scattering cross section used to normalize the data. The resultsmore » of a fit to a first-order Legendre polynomial expansion are in good agreement in the backward scattering hemisphere with the predictions of the Arndt et al. phase-shift analysis, those of the Nijmegen group, and to a lesser extent, with the ENDF/B-VII.0 evaluation. A fit to a second-order expansion is in better agreement with the ENDF/B-VII.0 evaluation than with the other predictions, in particular when the total elastic scattering cross section given by Arndt et al. and the Nijmegen group is used to normalize the data. A Legendre polynomial fit to the existing n-p scattering data in the 14 MeV energy region, excluding the present measurement, showed that a best fit is obtained for a second-order expansion. Furthermore, the Kolmogorov-Smirnov test confirms the general agreement in the backward scattering hemisphere and shows that significant differences between the database and the predictions occur in the angular range between 60 deg. and 120 deg. and below 20 deg. Although there is good overall agreement in the backward scattering hemisphere, more precision small-angle scattering data and a better definition of the total elastic cross section are needed for an accurate determination of the shape and magnitude of the angular distribution.« less
Comparison of fecal elastase-1 and pancreatic function testing in children.
Wali, Prateek D; Loveridge-Lenza, Beth; He, Zhaoping; Horvath, Karoly
2012-02-01
The fecal pancreatic elastase-1 (FE-1) test is considered a simple, noninvasive, indirect measure of pancreatic function. We aimed to evaluate the performance of the FE-1 test compared with the direct pancreatic function test (PFT) with secretin stimulation in children. Data of 70 children (6 months-17 years of age) who had both FE-1 test and PFT were analyzed. The average FE-1 concentration was 403 ± 142 μg/g. Eleven children had concentrations below 200 μg/g, 23 between 201 to 500 μg/g, and 36 were above 500 μg/g. The average pancreatic elastase activity measured on direct stimulation was 49.1 ± 38.6 μmol · min (-1)· ml(-1) and 11 children had activity below the established cutoff (10.5 μmol · min(-1) · ml(-1)). Among the 11 children with pathologic PFT, 7 had normal FE-1, 4 were in the intermediate range (201-500 μg/g), and none were in the low range (<200 μg/g). Among the 59 children with normal direct PFT 11 (19%) had pathologic (<200 μg/g) and 19 (32%) had intermediate FE-1 tests. Twenty-nine children had both normal FE-1 concentration and normal PFT, giving a negative predictive value of 80%. The correlation between pancreatic elastase activity and FE-1 concentration was poor (r = 0.190). The sensitivity of the FE-1 test was found to be 41.7%, whereas the specificity was 49.2%. The positive predictive value of the FE-1 test was only 14%. The FE-1 test is a simple, noninvasive, indirect method; however, ordering physicians should be aware of its limitations. It can give false-positive results and has low sensitivity in children with mild pancreatic insufficiency without cystic fibrosis and in those with isolated pancreatic enzyme deficiencies.
Wang, Rui; Li, Sa-Ying; Chen, Min; Zhou, Jin-Yuan; Peng, Dan-Tao; Zhang, Chen; Dai, Yong-Ming
2015-03-05
Amide proton transfer (APT) imaging has recently emerged as an important contrast mechanism for magnetic resonance imaging (MRI) in the field of molecular and cellular imaging. The aim of this study was to evaluate the feasibility of APT imaging to detect cerebral abnormality in patients with Alzheimer's disease (AD) at 3.0 Tesla. Twenty AD patients (9 men and 11 women; age range, 67-83 years) and 20 age-matched normal controls (11 men and 9 women; age range, 63-82 years) underwent APT and traditional MRI examination on a 3.0 Tesla MRI system. The magnetic resonance ratio asymmetry (MTR asym ) values at 3.5 ppm of bilateral hippocampi (Hc), temporal white matter regions, occipital white matter regions, and cerebral peduncles were measured on oblique axial APT images. MTR asym (3.5 ppm) values of the cerebral structures between AD patients and control subjects were compared with independent samples t-test. Controlling for age, partial correlation analysis was used to investigate the associations between mini-mental state examination (MMSE) and the various MRI measures among AD patients. Compared with normal controls, MTR asym (3.5 ppm) values of bilateral Hc were significantly increased in AD patients (right 1.24% ± 0.21% vs. 0.83% ± 0.19%, left 1.18% ± 0.18% vs. 0.80%± 0.17%, t = 3.039, 3.328, P = 0.004, 0.002, respectively). MTR asym (3.5 ppm) values of bilateral Hc were significantly negatively correlated with MMSE (right r = -0.559, P = 0.013; left r = -0.461, P = 0.047). Increased MTR asym (3.5 ppm) values of bilateral Hc in AD patients and its strong correlations with MMSE suggest that APT imaging could potentially provide imaging biomarkers for the noninvasive molecular diagnosis of AD.
Mei, Zhanyong; Ivanov, Kamen; Zhao, Guoru; Li, Huihui; Wang, Lei
2017-04-01
In the study of biomechanics of different foot types, temporal or spatial parameters derived from plantar pressure are often used. However, there is no comparative study of complexity and regularity of the center of pressure (CoP) during the stance phase among pes valgus, pes cavus, hallux valgus and normal foot. We aim to analyze whether CoP sample entropy characteristics differ among these four foot types. In our experiment participated 40 subjects with normal feet, 40 with pes cavus, 19 with pes valgus and 36 with hallux valgus. A Footscan ® system was used to collect CoP data. We used sample entropy to quantify several parameters of the investigated four foot types. These are the displacement in medial-lateral (M/L) and anterior-posterior (A/P) directions, as well as the vertical ground reaction force of CoP during the stance phase. To fully examine the potential of the sample entropy method for quantification of CoP components, we provide results for two cases: calculating the sample entropy of normalized CoP components, as well as calculating it using the raw data of CoP components. We also explored what are the optimal values of parameters m (the matching length) and r (the tolerance range) when calculating the sample entropy of CoP data obtained during the stance phases. According to statistical results, some factors significantly influenced the sample entropy of CoP components. The sample entropies of non-normalized A/P values for the left foot, as well as for the right foot, were different between the normal foot and pes valgus, and between the normal foot and hallux valgus. The sample entropy of normalized M/L displacement of the right foot was different between the normal foot and pes cavus. The measured variable for A/P and M/L displacements could serve for the study of foot function.
Nugent, S; Castellano, C A; Bocti, C; Dionne, I; Fulop, T; Cunnane, S C
2016-02-01
Our primary objective in this study was to quantify whole brain and regional cerebral metabolic rates of glucose (CMRg) in young and older adults in order to determine age-normalized reference CMRg values for healthy older adults with normal cognition for age. Our secondary objectives were to--(i) report a broader range of metabolic and endocrine parameters including body fat composition that could form the basis for the concept of a 'metabolic phenotype' in cognitively normal, older adults, and (ii) to assess whether medications commonly used to control blood lipids, blood pressure or thyroxine affect CMRg values in older adults. Cognition assessed by a battery of tests was normal for age and education in both groups. Compared to the young group (25 years old; n = 34), the older group (72 years old; n = 41) had ~14% lower CMRg (μmol/100 g/min) specifically in the frontal cortex, and 18% lower CMRg in the caudate. Lower grey matter volume and cortical thickness was widespread in the older group. These differences in CMRg, grey matter volume and cortical thickness were present in the absence of any known evidence for prodromal Alzheimer's disease (AD). Percent total body fat was positively correlated with CMRg in many brain regions but only in the older group. Before and after controlling for body fat, HOMA2-IR was significantly positively correlated to CMRg in several brain regions in the older group. These data show that compared to a healthy younger adult, the metabolic phenotype of a cognitively-normal 72 year old person includes similar plasma glucose, insulin, cholesterol, triglycerides and TSH, higher hemoglobin A1c and percent body fat, lower CMRg in the superior frontal cortex and caudate, but the same CMRg in the hippocampus and white matter. Age-normalization of cognitive test results is standard practice and we would suggest that regional CMRg in cognitively healthy older adults should also be age-normalized.
Kinetic effects on the velocity-shear-driven instability
NASA Technical Reports Server (NTRS)
Wang, Z.; Pritchett, P. L.; Ashour-Abdalla, M.
1992-01-01
A comparison is made between the properties of the low-frequency long-wavelength velocity-shear-driven instability in kinetic theory and magnetohydrodynamics (MHD). The results show that the removal of adiabaticity along the magnetic field line in kinetic theory leads to modifications in the nature of the instability. Although the threshold for the instability in the two formalisms is the same, the kinetic growth rate and the unstable range in wave-number space can be larger or smaller than the MHD values depending on the ratio between the thermal speed, Alfven speed, and flow speed. When the thermal speed is much larger than the flow speed and the flow speed is larger than the Alfven speed, the kinetic formalism gives a larger maximum growth rate and broader unstable range in wave-number space. In this regime, the normalized wave number for instability can be larger than unity, while in MHD it is always less than unity. The normal mode profile in the kinetic case has a wider spatial extent across the shear layer.
Blood platelet counts, morphology and morphometry in lions, Panthera leo.
Du Plessis, L
2009-09-01
Due to logistical problems in obtaining sufficient blood samples from apparently healthy animals in the wild in order to establish normal haematological reference values, only limited information regarding the blood platelet count and morphology of free-living lions (Panthera leo) is available. This study provides information on platelet counts and describes their morphology with particular reference to size in two normal, healthy and free-ranging lion populations. Blood samples were collected from a total of 16 lions. Platelet counts, determined manually, ranged between 218 and 358 x 10(9)/l. Light microscopy showed mostly activated platelets of various sizes with prominent granules. At the ultrastructural level the platelets revealed typical mammalian platelet morphology. However, morphometric analysis revealed a significant difference (P < 0.001) in platelet size between the two groups of animals. Basic haematological information obtained in this study may be helpful in future comparative studies between animals of the same species as well as in other felids.
Al-Hilal, Mohamed; Aissa, Mosa
2015-02-01
The concentrations of equivalent eU, eTh, and K% were determined together with soil gas radon values and carborne gamma-ray survey in order to define the natural radioactivity levels throughout main geological units of Sabkhat al Jabboul region. Forty five soil and rock samples were collected from various lithofacies in each geological unit, and analyzed by γ-ray spectrometric technique for determining the concentration values of major radioelements. Such radiometric data could be used to differentiate between various lithologies of the investigated rocks. Although no distinct radioactive anomalies were found in the area, the radiometric profiles showed some minor variations with slightly higher values than the normal level. Despite the low radioactivity and the lack of rocks diversity in the surveyed area, it was possible to classify some certain rock types based on their radiometric response. The relationships between eU, eTh and their ratios were discussed for the Quaternary, Neogene and Paleogene formations, in order to evaluate the degree of uranium distribution and remobilization. The overall results of this radiometric survey were generally low, and lying within the range of the normal background levels in Syrian. Copyright © 2014 Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Walker, A.L.; McCulloch, T.H.; Petersen, N.F.
1983-03-01
Forty-four subsurface samples of the nodular shale were collected from 14 selected wells located mostly between the Playa del Rey and Crescent Heights oil fields. Sites were selected to give the widest available range of sample depth and temperature where present burial depths are maximal, and where geothermal gradients are firmly established. Median random reflectance (%R/sub 0/) of first-cycle vitrinite is least in the shallowest samples, clusters about 0.24% in the deeper samples, and exceeds 0.30% only in the deepest and hottest samples. Extremes in the range of measured median %R/sub 0/ are tabulated below with corresponding extremes of samplemore » temperatures, depths, Time-Temperature Indices (TTI), and calculated %R/sub 0/ equivalents of the TTI values. All measured values of R/sub 0/ are significantly depressed compared to other maturity criteria. Significantly, second-cycle and oxidized vitrinite from these same samples show normally elevated reflectance. Eight of the samples processed for reflectance measurements were analyzed for total organic carbon content, which ranges from 2.21 to 9.41%. Most of the organic detritus is amorphous degraded algal material; less than 10% is structured vitrinite. Thermal alteration index values for the amorphous material range from 2 to 2 1/2, corresponding with hypothetical conversion R/sub 0/ values between 0.45 and 0.75%, again notably higher than the measured values. The ratios of extractable hydrocarbons to TOC in the 8 samples suggest mature levels of thermal evolution, as do carbon preference indices of 0.93 and 1.14 from extracts of 2 samples.« less
Lorenz, N D; Channon, S; Pettitt, R; Smirthwaite, P; Innes, J F
2015-01-01
Introduction of the Sirius® canine total elbow arthroplasty system, and presentation of the results of a passive range-of-motion analysis based on ex vivo kinematic studies pre-and post-implantation. Thoracic limbs (n = 4) of medium sized dogs were harvested by forequarter amputation. Plain orthogonal radiographs of each limb were obtained pre- and post-implantation. Limbs were prepared by placement of external fixator pins and Kirschner wires into the humerus and radius. Each limb was secured into a custom-made box frame and retro-reflective markers were placed on the exposed ends of the pins and wires. Each elbow was manually moved through five ranges-of-motion manoeuvres. Data collected included six trials of i) full extension to full flexion and ii) pronation and supination in 90° flexion; a three-dimensional motion capture system was used to collect and analyse the data. The Sirius elbow prosthesis was subsequently implanted and the same measurements were repeated. Data sets were tested for normality. Paired t-tests were used for comparison of pre- and post-implantation motion parameters. Kinematic analysis showed that the range-of-motion (mean and SD) for flexion and extension pre-implantation was 115° ± 6 (range: 25° to 140°). The range-of-motion in the sagittal plane post-implantation was 90° ± 4 (range: 36° to 130°) and this reduction was significant (p = 0.0001). The ranges-of-motion (mean and SD) for supination and pronation at 90° were 50° ± 5, whereas the corresponding mean ranges-of-motion post-implantation were 38° ± 6 (p = 0.0188). Compared to a normal elbow, the range-of-motion was reduced. Post-implantation, supination and pronation range-of-motion was significantly reduced at 90° over pre-implantation values. These results provide valuable information regarding the effect of the Sirius system on ex vivo kinematics of the normal canine elbow joint. Further, this particular ex vivo model allowed for satisfactory and repeatable kinematic analysis.
Assessment of visual disability using visual evoked potentials.
Jeon, Jihoon; Oh, Seiyul; Kyung, Sungeun
2012-08-06
The purpose of this study is to validate the use of visual evoked potential (VEP) to objectively quantify visual acuity in normal and amblyopic patients, and determine if it is possible to predict visual acuity in disability assessment to register visual pathway lesions. A retrospective chart review was conducted of patients diagnosed with normal vision, unilateral amblyopia, optic neuritis, and visual disability who visited the university medical center for registration from March 2007 to October 2009. The study included 20 normal subjects (20 right eyes: 10 females, 10 males, ages 9-42 years), 18 unilateral amblyopic patients (18 amblyopic eyes, ages 19-36 years), 19 optic neuritis patients (19 eyes: ages 9-71 years), and 10 patients with visual disability having visual pathway lesions. Amplitude and latencies were analyzed and correlations with visual acuity (logMAR) were derived from 20 normal and 18 amblyopic subjects. Correlation of VEP amplitude and visual acuity (logMAR) of 19 optic neuritis patients confirmed relationships between visual acuity and amplitude. We calculated the objective visual acuity (logMAR) of 16 eyes from 10 patients to diagnose the presence or absence of visual disability using relations derived from 20 normal and 18 amblyopic eyes. Linear regression analyses between amplitude of pattern visual evoked potentials and visual acuity (logMAR) of 38 eyes from normal (right eyes) and amblyopic (amblyopic eyes) subjects were significant [y = -0.072x + 1.22, x: VEP amplitude, y: visual acuity (logMAR)]. There were no significant differences between visual acuity prediction values, which substituted amplitude values of 19 eyes with optic neuritis into function. We calculated the objective visual acuity of 16 eyes of 10 patients to diagnose the presence or absence of visual disability using relations of y = -0.072x + 1.22 (-0.072). This resulted in a prediction reference of visual acuity associated with malingering vs. real disability in a range >5.77 μV. The results could be useful, especially in cases of no obvious pale disc with trauma. Visual acuity quantification using absolute value of amplitude in pattern visual evoked potentials was useful in confirming subjective visual acuity for cutoff values >5.77 μV in disability evaluation to discriminate the malingering from real disability.
Assessment of visual disability using visual evoked potentials
2012-01-01
Background The purpose of this study is to validate the use of visual evoked potential (VEP) to objectively quantify visual acuity in normal and amblyopic patients, and determine if it is possible to predict visual acuity in disability assessment to register visual pathway lesions. Methods A retrospective chart review was conducted of patients diagnosed with normal vision, unilateral amblyopia, optic neuritis, and visual disability who visited the university medical center for registration from March 2007 to October 2009. The study included 20 normal subjects (20 right eyes: 10 females, 10 males, ages 9–42 years), 18 unilateral amblyopic patients (18 amblyopic eyes, ages 19–36 years), 19 optic neuritis patients (19 eyes: ages 9–71 years), and 10 patients with visual disability having visual pathway lesions. Amplitude and latencies were analyzed and correlations with visual acuity (logMAR) were derived from 20 normal and 18 amblyopic subjects. Correlation of VEP amplitude and visual acuity (logMAR) of 19 optic neuritis patients confirmed relationships between visual acuity and amplitude. We calculated the objective visual acuity (logMAR) of 16 eyes from 10 patients to diagnose the presence or absence of visual disability using relations derived from 20 normal and 18 amblyopic eyes. Results Linear regression analyses between amplitude of pattern visual evoked potentials and visual acuity (logMAR) of 38 eyes from normal (right eyes) and amblyopic (amblyopic eyes) subjects were significant [y = −0.072x + 1.22, x: VEP amplitude, y: visual acuity (logMAR)]. There were no significant differences between visual acuity prediction values, which substituted amplitude values of 19 eyes with optic neuritis into function. We calculated the objective visual acuity of 16 eyes of 10 patients to diagnose the presence or absence of visual disability using relations of y = −0.072x + 1.22 (−0.072). This resulted in a prediction reference of visual acuity associated with malingering vs. real disability in a range >5.77 μV. The results could be useful, especially in cases of no obvious pale disc with trauma. Conclusions Visual acuity quantification using absolute value of amplitude in pattern visual evoked potentials was useful in confirming subjective visual acuity for cutoff values >5.77 μV in disability evaluation to discriminate the malingering from real disability. PMID:22866948
Serum Antioxidant Status in Patients with Systemic Sclerosis
Hassan, Iffat; Sajad, Peerzada; Majid, Sabiya; Hassan, Tehseen
2013-01-01
Background: Vascular endothelial dysfunction is a central event in pathogenesis of a variety of human diseases. Systemic sclerosis is one of such diseases. The oxidative stress and depletion of antioxidants in the serum is believed to be one of the factors in causing this dysfunction. Aims: The aim of this case control study was to compare the levels of antioxidants in the serum of patients with systemic sclerosis and the normal age and sex matched controls. Materials and Methods: Our study consisted of 16 successively admitted patients with systemic sclerosis and 16 healthy, age and sex matched controls. The age group of patient's ranged between 25 and 55 years. The duration of the disease in patients ranged from 1 to 8 years. The serum of patients and controls were assayed for the levels of antioxidants (GSH, NO, MDA, SOD and GPX) by spectrophotometry. The statistical method of analysis used was the one sample t-test. Results: The median levels of antioxidants in the control patients were: SOD-4.14 units/ml; GSH-4.76 units/ml; NO-5.58 nmol/l; MDA-0.53 nmol/l and GPX-49 μmol/l. The levels of NO, GSH and SOD were decreased in these patients with a significant P value (<0.001) whereas the levels of GPX and MDA were normal to increased with a significant P value. Conclusion: The depletion of antioxidants and oxidative stress in serum might be responsible for the vascular dysfunction and other hallmark manifestations of systemic sclerosis. Therefore micronutrient antioxidant supplements may be of therapeutic value. PMID:23723482
Safety analysis of proposed data-driven physiologic alarm parameters for hospitalized children.
Goel, Veena V; Poole, Sarah F; Longhurst, Christopher A; Platchek, Terry S; Pageler, Natalie M; Sharek, Paul J; Palma, Jonathan P
2016-12-01
Modification of alarm limits is one approach to mitigating alarm fatigue. We aimed to create and validate heart rate (HR) and respiratory rate (RR) percentiles for hospitalized children, and analyze the safety of replacing current vital sign reference ranges with proposed data-driven, age-stratified 5th and 95th percentile values. In this retrospective cross-sectional study, nurse-charted HR and RR data from a training set of 7202 hospitalized children were used to develop percentile tables. We compared 5th and 95th percentile values with currently accepted reference ranges in a validation set of 2287 patients. We analyzed 148 rapid response team (RRT) and cardiorespiratory arrest (CRA) events over a 12-month period, using HR and RR values in the 12 hours prior to the event, to determine the proportion of patients with out-of-range vitals based upon reference versus data-driven limits. There were 24,045 (55.6%) fewer out-of-range measurements using data-driven vital sign limits. Overall, 144/148 RRT and CRA patients had out-of-range HR or RR values preceding the event using current limits, and 138/148 were abnormal using data-driven limits. Chart review of RRT and CRA patients with abnormal HR and RR per current limits considered normal by data-driven limits revealed that clinical status change was identified by other vital sign abnormalities or clinical context. A large proportion of vital signs in hospitalized children are outside presently used norms. Safety evaluation of data-driven limits suggests they are as safe as those currently used. Implementation of these parameters in physiologic monitors may mitigate alarm fatigue. Journal of Hospital Medicine 2015;11:817-823. © 2015 Society of Hospital Medicine. © 2016 Society of Hospital Medicine.
NASA Technical Reports Server (NTRS)
Ferris, J. C.
1973-01-01
The Langley 8-foot transonic pressure tunnel to determine the wing chordwise pressure distribution for a 0.09-scale model of a research airplane incorporating a 17-percent-thick supercritical wing. Airfoil profile drag was determined from wake pressure measurements at the 42-percent-semispan wing station. The investigation was conducted at Mach numbers from 0.30 to 0.80 over an angle-of-attack range sufficient to include buffet onset. The Reynolds number based on the mean geometric chord varied from 2 x 10 to the 6th power at Mach number 0.30 to 3.33 x 10 to the 6th power at Mach number 0.65 and was maintained at a constant value of 3.86 x 10 to the 6th power at Mach numbers from 0.70 to 0.80. Pressure coefficients for four wing semispan stations and wing-section normal-force and pitching-moment coefficients for two semispan stations are presented in tabular form over the Mach number range from 0.30 to 0.80. Plotted chordwise pressure distributions and wake profiles are given for a selected range of section normal-force coefficients over the same Mach number range.
Seo, Sang Gyo; Kim, Eo Jin; Lee, Doo Jae; Bae, Kee Jeong; Lee, Kyoung Min; Lee, Dong Yeon
2017-09-01
Total ankle replacement (TAR) and ankle arthrodesis (AA) are usually performed for severe ankle arthritis. We compared postoperative foot segmental motion during gait in patients treated with TAR and AA. Gait analysis was performed in 17 and 7 patients undergoing TAR and AA, respectively. Subjects were evaluated using a 3-dimensional multisegmental foot model with 15 markers. Temporal gait parameters were calculated. The maximum and minimum values and the differences in hallux, forefoot, hindfoot, and arch in 3 planes (sagittal, coronal, transverse) were compared between the 2 groups. One hundred healthy adults were evaluated as a control. Gait speed was faster in the TAR ( P = .028). On analysis of foot and ankle segmental motion, the range of hindfoot sagittal motion was significantly greater in the TAR (15.1 vs 10.2 degrees in AA; P = .004). The main component of motion increase was hindfoot dorsiflexion (12.3 and 8.6 degrees). The range of forefoot sagittal motion was greater in the TAR (9.3 vs 5.8 degrees in AA; P = .004). Maximum ankle power in the TAR (1.16) was significantly higher than 0.32 in AA; P = .008). However, the range of hindfoot and forefoot sagittal motion was decreased in both TAR and AA compared with the control group ( P = .000). Although biomechanical results of TAR and AA were not similar to those in the normal controls, joint motions in the TAR more closely matched normal values. Treatment decision making should involve considerations of the effect of surgery on the adjacent joints. Level III, case-control study.
Griffin, Darvin J; Bonnevie, Edward D; Lachowsky, Devin J; Hart, James C A; Sparks, Holly D; Moran, Nance; Matthews, Gloria; Nixon, Alan J; Cohen, Itai; Bonassar, Lawrence J
2015-07-16
There has been much interest in using autologous chondrocytes in combination with scaffold materials to aid in cartilage repair. In the present study, a total of 27 animals were used to compare the performance of matrix-assisted chondrocyte implantation (MACI®) using a collagen sponge as a chondrocyte delivery vehicle, the sponge membrane alone, and empty controls. A total of three distinct types of mechanical analyses were performed on repaired cartilage harvested from horses after 53 weeks of implantation: (1) compressive behavior of samples to measure aggregate modulus (HA) and hydraulic permeability (k) in confined compression; (2) local and global shear modulus using confocal strain mapping; and (3) boundary friction coefficient using a custom-built tribometer. Cartilage defects receiving MACI® implants had equilibrium modulus values that were 70% of normal cartilage, and were not statistically different than normal tissue. Defects filled with Maix™ membrane alone or left empty were only 46% and 51-63% of control, respectively. The shear modulus of tissue from all groups of cartilage defects were between 4 and 10 times lower than control tissue, and range from 0.2 to 0.4 MPa. The average values of boundary mode friction coefficients of control tissue from all groups ranged from 0.42 to 0.52. This study represents an extensive characterization of the mechanical performance of the MACI® grafts implant in a large animal model at 53 weeks. Collectively, these data demonstrate a range of implant performance, revealing similar compressive and frictional properties to native tissue, with inferior shear properties. Copyright © 2015. Published by Elsevier Ltd.
Park, Jae-Hyeong; Choi, Jin-Oh; Park, Seung Woo; Cho, Goo-Yeong; Oh, Jin Kyung; Lee, Jae-Hwan; Seong, In-Whan
2018-02-01
Right ventricular (RV) strain values by 2-dimensional strain echocardiography (STE) can be used as objective markers of RV systolic function. However, there is little data about normal reference RV strain values according to age and gender. We measured normal RV strain values by STE. RV strain values were analyzed from the digitally stored echocardiographic images from NORMAL (Normal echOcardiogRaphic diMensions and functions in KoreAn popuLation) study for the measurement of normal echocardiographic values performed in 23 Korean university hospitals. We enrolled total 1003 healthy persons in the NORMAL study. Of them, we analyzed 2-dimensional RV strain values in 493 subjects (261 females, mean 47 ± 15 years old) only with echocardiographic images by GE machines. Their LV systolic and diastolic functions were normal. RV fractional area change was 48 ± 6% and tricuspid annular plane systolic excursion was 23 ± 3 mm. Total RV global longitudinal peak systolic strain (RVGLS total ) was -21.5 ± 3.2%. Females had higher absolute RVGLS total (-22.3 ± 3.3 vs -20.7 ± 2.9%, p < 0.001) than males. Younger (<50 years old) females had higher absolute RVGLS total (-22.9 ± 3.2 vs -20.5 ± 2.8%, p < 0.001) than age matched males. RVGLS total in females gradually increased according to age (p for trend = 0.002) and becomes almost similar in age ≥50 years. However, this trend was not seen in males (p for trend = 0.287), and younger males had similar RVGLS total value to that of older males (age ≥50 years, -20.5 ± 2.8 vs -20.9 ± 3.1%, p = 0.224). We calculated normal RVGLS values in normal population. Females have higher absolute strain values than males, especially in younger age groups (<50 years old).
Pi, Yin-Zhen; Wu, Xian-Ping; Liu, Shi-Ping; Luo, Xiang-Hang; Cao, Xing-Zhi; Xie, Hui; Liao, Er-Yuan
2006-01-01
Measurements of bone biochemical markers are increasingly being used to evaluate the state of bone turnover in the management of bone metabolic diseases, especially osteoporosis. However, changes in the bone turnover rate vary with age. The aim of this study was to establish the laboratory reference range of serum bone-specific alkaline phosphatase (sBAP), serum type I collagen cross-linked C-terminal telopeptide (sCTx), and urine CTx (uCTx), based on values from 665 healthy Chinese women aged 20-80 years. We measured the levels of sBAP, sCTx, serum alkaline phosphatase (sALP), and uCTx and evaluated the age-related changes and their relationship with bone mineral density (BMD) in the anteroposterior (AP) lumbar spine, hip, and left forearm. We found significant correlations between biochemical markers and age, with coefficients of determination (R (2)) of 0.358 for sBAP, 0.126 for sCTx, 0.125 for uCTx, and 0.336 for sALP. The net changes in different biochemical markers were inversely correlated with the rates of BMD loss in the AP lumbar spine. After correction for age, body weight, and height, the levels of the markers had significant negative correlations with the BMD of the AP lumbar spine, femoral neck, and ultradistal forearm. All four biochemical markers had the highest negative correlation with BMD of the AP lumbar spine (partial correlation coefficients of -0.366, -0.296, -0.290, and -0.258 for sBAP, sCTx, uCTx, and sALP, respectively). The mean and SD values of these markers in premenopausal and postmenopausal women with normal BMD values were used as the normal reference ranges. The reference ranges of sBAP, sCTx, and uCTx for pre- vs postmenopausal women were 17.3 +/- 6.23 vs 18.9 +/- 7.52 U/l, 3.18 +/- 1.49 vs 3.23 +/- 1.57 nmol/l, and 15.5 +/- 11.4 vs 16.2 +/- 12.4 nM bone collagen equivalents/mM urinary creatinine, respectively. Levels of the bone formation marker (sBAP) and bone resorption markers (sCTx, uCTx) increased rapidly in women with osteopenia or osteoporosis, indicating that they may be sensitive markers to determine the bone turnover rate in healthy Chinese women.
Diagnostic Performance of Serum IgG4 Levels in Patients With IgG4-Related Disease
Yu, Kuang-Hui; Chan, Tien-Ming; Tsai, Ping-Han; Chen, Ching-Hui; Chang, Pi-Yueh
2015-01-01
Abstract The aim of this study is to study the clinical features and diagnostic performance of IgG4 in Chinese populations with IgG4-related diseases (IgG4-RDs). The medical records of 2901 adult subjects who underwent serum IgG4 level tests conducted between December 2007 and May 2014 were reviewed. Serum concentrations of IgG4 were measured in 2901 cases, including 161 (5.6%) patients with IgG4-RD and 2740 (94.4%) patients without IgG4-RD (non-IgG4-RD group). The mean age of the IgG4-RD patients was 58.4 ± 16.1 years (range: 21–87), and 48 (29.8%) were women. The mean serum IgG4 level was significantly much higher in IgG4-RD patients than in non-IgG4-RD (1062.6 vs 104.3 mg/dL, P < 0.001) participants. For IgG4 >135 mg/dL, the sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), likelihood ratio (LR)+, and LR− were 86%, 77%, 18%, 99%, 3.70, and 0.19, respectively. When the upper limit of normal was doubled for an IgG4 >270 mg/dL, the corresponding data were 75%, 94%, 43%, 98%, 12.79, and 0.26, respectively. For IgG4 >405 mg/dL (tripling the upper limit of normal), the corresponding data were 62%, 98%, 68%, 98%, 37.00, and 0.39, respectively. When calculated according to the manufacturer's package insert cutoff (>201 mg/dL) for the diagnosis of IgG4-RD, the corresponding sensitivity, specificity, PPV, NPV, LR+, and LR− were 80%, 89%, 29%, 99%, 7.00, and 0.23, respectively. For IgG4 >402 mg/dL (>2× the upper limit of the normal range), the corresponding data were 62%, 98%, 68%, 98%, 36.21, and 0.39, respectively. For IgG4 >603 mg/dL (>3× the upper limit of the normal range), the corresponding data were 50%, 99%, 84%, 97%, 90.77 and 0.51, respectively. The optimal cutoff value of serum IgG4 (measured by nephelometry using a Siemens BN ProSpec instrument and Siemens reagent) for the diagnosis of IgG4-RD was 248 mg/dL, the sensitivity and specificity were 77.6% and 92.8%, respectively. The present study demonstrated that 2 or 3 times the upper limit of the manufacturer's reference range of the IgG4 level was a useful marker for the diagnosis of various types of IgG4-RD and the optimal cutoff level was 248 mg/dL. PMID:26469909
Transient boiling in two-phase helium natural circulation loops
NASA Astrophysics Data System (ADS)
Furci, H.; Baudouy, B.; Four, A.; Meuris, C.
2014-01-01
Two-phase helium natural circulation loops are used for cooling large superconducting magnets, as CMS for LHC. During normal operation or in the case of incidents, transients are exerted on the cooling system. Here a cooling system of this type is studied experimentally. Sudden power changes are operated on a vertical-heated-section natural convection loop, simulating a fast increase of heat deposition on magnet cooling pipes. Mass flow rate, heated section wall temperature and pressure drop variations are measured as a function of time, to assess the time behavior concerning the boiling regime according to the values of power injected on the heated section. The boiling curves and critical heat flux (CHF) values have been obtained in steady state. Temperature evolution has been observed in order to explore the operating ranges where heat transfer is deteriorated. Premature film boiling has been observed during transients on the heated section in some power ranges, even at appreciably lower values than the CHF. A way of attenuating these undesired temperature excursions has been identified through the application of high enough initial heating power.
Jang, Yongjun; Park, Geun-Young; Park, Jihye; Choi, Asayeon; Kim, Soo Yeon; Boulias, Chris; Phadke, Chetan P; Ismail, Farooq; Im, Sun
2016-04-01
To evaluate Korean physiatrists' practice of performing intramuscular botulinum toxin injection in anticoagulated patients and to assess their preference in controlling the bleeding risk before injection. As part of an international collaboration survey study, a questionnaire survey was administered to 100 Korean physiatrists. Physiatrists were asked about their level of experience with botulinum toxin injection, the safe international normalized ratio range in anticoagulated patients undergoing injection, their tendency for injecting into deep muscles, and their experience of bleeding complications. International normalized ratio <2.0 was perceived as an ideal range for performing Botulinum toxin injection by 41% of the respondents. Thirty-six respondents replied that the international normalized ratio should be lowered to sub-therapeutic levels before injection, and 18% of the respondents reported that anticoagulants should be intentionally withheld and discontinued prior to injection. In addition, 20%-30% of the respondents answered that they were uncertain whether they should perform the injection regardless of the international normalized ratio values. About 69% of the respondents replied that they did have any standardized protocols for performing botulinum toxin injection in patients using anticoagulants. Only 1 physiatrist replied that he had encountered a case of compartment syndrome. In accordance with the lack of consensus in performing intramuscular botulinum toxin injection in anticoagulated patients, our survey shows a wide range of practices among many Korean physiatrists; they tend to avoid botulinum toxin injection in anticoagulated patients and are uncertain about how to approach these patients. The results of this study emphasize the need for formulating a proper international consensus on botulinum toxin injection management in anticoagulated patients.
Valdés, Sergio; Maldonado-Araque, Cristina; Lago-Sampedro, Ana; Lillo-Muñoz, Juan Antonio; Garcia-Fuentes, Eduardo; Perez-Valero, Vidal; Gutiérrez-Repiso, Carolina; Garcia-Escobar, Eva; Goday, Albert; Urrutia, Inés; Peláez, Laura; Calle-Pascual, Alfonso; Bordiú, Elena; Castaño, Luis; Castell, Conxa; Delgado, Elias; Menéndez, Edelmiro; Franch-Nadal, Josep; Gaztambide, Sonia; Girbés, Joan; Ortega, Emilio; Vendrell, Joan; Chacón, Matilde R; Javier Chaves, F; Soriguer, Federico; Rojo-Martínez, Gemma
2017-04-01
To analyze the reference range of thyroid-stimulating hormone (TSH) in different BMI categories and its impact on the classification of hypothyroidism. The study included 3,928 individuals free of thyroid disease (without previous thyroid disease, no interfering medications, TSH <10 µUI/mL and thyroid peroxidase antibodies [TPO Abs] <50 IU/mL) who participated in a national, cross-sectional, population-based study and were representative of the adult population of Spain. Data gathered included clinical and demographic characteristics, physical examination, and blood and urine sampling. TSH, free thyroxine, free triiodothyronine, and TPO Ab were analyzed by electrochemiluminescence (E170, Roche Diagnostics, Basel, Switzerland). The reference range (p2.5-97.5) for TSH was estimated as 0.6 to 4.8 µUI/mL in the underweight category (BMI<20 kg/m 2 ), 0.6 to 5.5 µUI/mL in the normal-weight category (BMI 20-24.9 kg/m 2 ), 0.6 to 5.5 µUI/mL in the overweight category (BMI 25-29.9 kg/m 2 ), 0.5 to 5.9 µUI/mL in the obesity category (BMI 30-39.9 kg/m 2 ), and 0.7 to 7.5 µUI/mL in the morbid obesity category (BMI ≥40). By using the reference criteria for the normal-weight population, the prevalence of high TSH levels increased threefold in the morbid obesity category (P < 0.01). Persons with morbid obesity might be inappropriately classified if the standard ranges of normality of TSH for the normal-weight population are applied to them. © 2017 The Obesity Society.
A survey of the clinical use of SeHCAT in the UK.
Smith, Michael J; Perkins, Alan C
2013-04-01
The radiopharmaceutical 23-(Se)selena-25-homotaurocholic acid (SeHCAT), introduced 30 years ago, serves as a convenient and reliable diagnostic test for bile acid malabsorption. Recent advances in understanding the pathophysiology of bile acid diarrhoea have led to increased use of SeHCAT; however, some questions on its applicability remain unanswered. To obtain a better understanding of the application of this diagnostic test, a national survey was carried out within the UK. A web-based semistructured questionnaire was used. Invitations to participate were sent to the lead contacts of the 227 Nuclear Medicine Departments in the UK known to the British Nuclear Medicine Society. Information was sought on workload, trends in referrals, acquisition protocols, patient preparation, results, normal ranges and interpretation. For those not using SeHCAT, questions on reasons for not using the test and intentions to commence its use in the future were asked. Responses from 129 UK centres were included in analysis. Seventy-three of these (57%) used SeHCAT in diagnosis, and most of them reported an increase in referrals over the last 3 years. Several departments have started using SeHCAT recently in response to demand from clinicians. There was considerable variability in the practical implementation of the technique and the 'normal' range used for reporting. The findings from the survey have provided a better understanding of how diagnosis using SeHCAT is carried out in the UK. An important finding was the wide variation in the normal reference values used for diagnostic reporting. Establishing greater consistency in the interpretation and reporting of the results of this test would be of considerable clinical value.
Clinical Features of Lysosomal Acid Lipase Deficiency.
Burton, Barbara K; Deegan, Patrick B; Enns, Gregory M; Guardamagna, Ornella; Horslen, Simon; Hovingh, Gerard K; Lobritto, Steve J; Malinova, Vera; McLin, Valerie A; Raiman, Julian; Di Rocco, Maja; Santra, Saikat; Sharma, Reena; Sykut-Cegielska, Jolanta; Whitley, Chester B; Eckert, Stephen; Valayannopoulos, Vassili; Quinn, Anthony G
2015-12-01
The aim of this study was to characterize key clinical manifestations of lysosomal acid lipase deficiency (LAL D) in children and adults. Investigators reviewed medical records of LAL D patients ages ≥5 years, extracted historical data, and obtained prospective laboratory and imaging data on living patients to develop a longitudinal dataset. A total of 49 patients were enrolled; 48 had confirmed LAL D. Mean age at first disease-related abnormality was 9.0 years (range 0-42); mean age at diagnosis was 15.2 years (range 1-46). Twenty-nine (60%) were male patients, and 27 (56%) were <20 years of age at the time of consent/assent. Serum transaminases were elevated in most patients with 458 of 499 (92%) of alanine aminotransferase values and 265 of 448 (59%) of aspartate aminotransferase values above the upper limit of normal. Most patients had elevated low-density lipoprotein (64% patients) and total cholesterol (63%) at baseline despite most being on lipid-lowering therapies, and 44% had high-density lipoprotein levels below the lower limit of normal. More than half of the patients with liver biopsies (n = 31, mean age 13 years) had documented evidence of steatosis (87%) and/or fibrosis (52%). Imaging assessments revealed that the median liver volume was ∼1.15 multiples of normal (MN) and median spleen volume was ∼2.2 MN. Six (13%) patients had undergone a liver transplant (ages 9-43.5 years). This study provides the largest longitudinal case review of patients with LAL D and confirms that LAL D is predominantly a pediatric disease causing early and progressive hepatic dysfunction associated with dyslipidemia that often leads to liver failure and transplantation.
Stechman, Michael J; Ahmad, Bushra N; Loh, Nellie Y; Reed, Anita A C; Stewart, Michelle; Wells, Sara; Hough, Tertius; Bentley, Liz; Cox, Roger D; Brown, Steve D M; Thakker, Rajesh V
2010-07-01
Physiological studies of mice are facilitated by normal plasma and 24-hour urinary reference ranges, but variability of these parameters may increase due to stress that is induced by housing in metabolic cages. We assessed daily weight, food and water intake, urine volume and final day measurements of the following: plasma sodium, potassium, chloride, urea, creatinine, calcium, phosphate, alkaline phosphatase, albumin, cholesterol and glucose; and urinary sodium, potassium, calcium, phosphate, glucose and protein in 24- to 30-week-old C3H/HeH, BALB/cAnNCrl and C57BL/6J mice. Between 15 and 20 mice of each sex from all three strains were individually housed in metabolic cages with ad libitum feeding for up to seven days. Acclimatization was evaluated using general linear modelling for repeated measures and comparison of biochemical data was by unpaired t-test and analysis of variance (SPSS version 12.0.1). Following an initial 5-10% fall in body weight, daily dietary intake, urinary output and weight in all three strains reached stable values after 3-4 days of confinement. Significant differences in plasma glucose, cholesterol, urea, chloride, calcium and albumin, and urinary glucose, sodium, phosphate, calcium and protein were observed between strains and genders. Thus, these results provide normal reference values for plasma and urinary biochemistry in three strains housed in metabolic cages and demonstrate that 3-4 days are required to reach equilibrium in metabolic cage studies. These variations due to strain and gender have significant implications for selecting the appropriate strain upon which to breed genetically-altered models of metabolic and renal disease.
Light scattering from normal and cervical cancer cells.
Lin, Xiaogang; Wan, Nan; Weng, Lingdong; Zhou, Yong
2017-04-20
The light scattering characteristic plays a very important role in optic imaging and diagnostic applications. For optical detection of the cell, cell scattering characteristics have an extremely vital role. In this paper, we use the finite-difference time-domain (FDTD) algorithm to simulate the propagation and scattering of light in biological cells. The two-dimensional scattering cell models were set up based on the FDTD algorithm. The cell models of normal cells and cancerous cells were established, and the shapes of organelles, such as mitochondria, were elliptical. Based on these models, three aspects of the scattering characteristics were studied. First, the radar cross section (RCS) distribution curves of the corresponding cell models were calculated, then corresponding relationships between the size and the refractive index of the nucleus and light scattering information were analyzed in the three periods of cell canceration. The values of RCS increase positively with the increase of the nucleo-cytoplasmic ratio in the cancerous process when the scattering angle ranges from 0° to 20°. Second, the effect of organelles in the scattering was analyzed. The peak value of the RCS of cells with mitochondria is higher than the cells without mitochondria when the scattering angle ranges from 20° to 180°. Third, we demonstrated that the influence of cell shape is important, and the impact was revealed by the two typical ideal cells: round cells and oval cells. When the scattering angle ranges from 0° to 80°, the peak values and the frequencies of the appearance of the peaks from the two models are roughly similar. It can be concluded that: (1) the size of the nuclei and the change of the refractive index of cells have a certain impact on light scattering information of the whole cell; (2) mitochondria and other small organelles contribute to the cell light scattering characteristics in the larger scattering angle area; and (3) the change of the cell shape significantly influences the value of scattering peak and the deviation of scattering peak position. The results of the numerical simulation will guide subsequent experiments and early diagnosis of cervical cancer.
Yao, Bo; Li, Rui; Yan, Shuwen; Chan, Shen-An; Song, Weihua
2018-05-18
Steroid hormones (SHs) are continuously released into the aquatic environment through various pathways after being excreted by humans and animals, interfere with the normal function of the endocrine system and may affect the physiology and reproduction of exposed aquatic life. To conduct a nationwide investigation of the occurrence and biological effects of SHs in surface river/steam water in China, we quantitated 27 selected SHs in 217 surface water samples by solid-phase extraction (SPE) tandem LC-MS/MS and used a recombinant yeast estrogen assay to screen extracts of the water samples for estrogenic activities. SHs were commonly found in the surface water samples, and their levels were typically in the ng L -1 range. Estrone (E1) and estriol (E3) were normally present in several to dozens of times higher concentrations than estradiol (E2) and 17-a-Ethinylestradiol (EE2). The high concentrations (mean > 1 μg L -1 ) of Sum SHs were primarily obtained in areas under extreme water stress, specifically the eastern coastal areas. Source apportionment based on the profiles of the target compounds indicated that 54.5% of the SHs in target samples came from freshly discharged untreated sewage. The estrogen equivalent (EEQ (bio) ) values ranged from 0.01 to 40.27 ng L -1 , and the calculated EEQ (EEQ (cal) ) values were generally lower than the corresponding EEQ (bio) values for all samples. E2 was the main contributor to the estrogenicity among the three estrogens, with a contribution ratio of 82.8%. The risk quotient values of E2 were highest and ranged from 1.55 to 782.95, and 76.0% of the target surface samples displayed the greatest environmental risk. We concluded that the impacts of SHs on humans in Chinese surface waters should not be ignored and that certain actions should be taken to decrease the levels of SHs in source waters, especially measures targeting SHs in untreated wastewater from the vast rural areas. Copyright © 2018. Published by Elsevier Ltd.
Experimental investigation of cephapirin adsorption to quartz filter sands and dune sands
NASA Astrophysics Data System (ADS)
Peterson, Jonathan W.; O'Meara, Theresa A.; Seymour, Michael D.
2008-08-01
Batch experiments were performed to investigate cephapirin (a widely used veterinary antibiotic) adsorption on various size sands of low total organic carbon content (0.08-0.36 wt%). In the aqueous concentration range investigated (11-112 μmol/L cephapirin), adsorption to nearly pure quartz filter sands (0.50-3.35 mm diameter) is low. Isotherms are S-shaped and most display a region of minimum adsorption, where decreased adsorption occurs with increasing solution concentration, followed by increased adsorption at higher concentrations. Cephapirin adsorption to quartz-rich, feldspar-bearing dune sands (0.06-0.35 mm diameter), and the smallest quartz filter sand investigated (0.43-0.50 mm), can be described by linear sorption isotherms over the range of concentrations investigated. Distribution coefficients ( K d) range from 0.94 to 3.45 L/kg. No systematic relationship exists between grain size and amount of adsorption for any of the sands investigated. Cephapirin adsorption is positively correlated to the feldspar ratio (K-feldspar/(albite + Ca-plagioclase). Feldspar-ratio normalization of distribution coefficients was more effective than organic carbon normalization at reducing variability of K d values in the dune sands investigated.
NASA Astrophysics Data System (ADS)
Shreedharan, S.; Riviere, J.; Marone, C.
2017-12-01
We report on a suite of laboratory friction experiments conducted on saw-cut Westerly Granite surfaces to probe frictional response to step changes in normal stress and loading rate. The experiments are conducted to illuminate the fundamental processes that yield friction rate and state dependence. We quantify the microphysical frictional response of the simulated fault surfaces to normal stress steps, in the range of 1% - 600% step increases and decreases from a nominal baseline normal stress. We measure directly the fault slip rate and account for changes in slip rate with changes in normal stress and complement mechanical data acquisition by continuously probing the faults with ultrasonic pulses. We conduct the experiments at room temperature and humidity conditions in a servo controlled biaxial testing apparatus in the double direct shear configuration. The samples are sheared over a range of velocities, from 0.02 - 100 μm/s. We report observations of a transient shear stress and friction evolution with step increases and decreases in normal stress. Specifically, we show that, at low shear velocities and small increases in normal stress (<5% increase), the shear stress on the fault does not increase instantaneously with the normal stress step while the ultrasonic wave amplitude and normal displacement do. In other words, the shear stress does not follow the load point stiffness curve. At high shear velocities and larger normal stress steps (> 5% increases), the shear stress evolves immediately with normal stress. We show that the excursions in slip rate resulting from the changes in normal stress must be accounted for in order to predict fault strength evolution. Ultrasonic wave amplitudes which first increase immediately in response to normal stress steps, then decrease approximately linearly to a new steady state value, in part due to changes in fault slip rate. Previous descriptions of frictional state evolution during normal stress perturbations have not adequately accounted for the effect of large slip velocity excursions. Here, we attempt to do so by using the measured ultrasonic amplitudes as a proxy for frictional state during transient shear stress evolution. Our work aims to improve understanding of induced and triggered seismicity with focus on simulating static triggering using rate and state friction.
NASA Technical Reports Server (NTRS)
Weizer, Victor G.; Fatemi, Navid S.
1991-01-01
An investigation is made into the possibility of providing low resistance contacts to shallow junction InP solar cells which do not require sintering and which do not cause device degradation even when subjected to extended annealing at elevated temperatures. We show that the addition of In to Au contacts in amounts that exceed the solid solubility limit lowers the as-fabricated (unsintered) contact resistivity (R sub c) to the 10(exp -5) ohm cm(exp 2) range. We next consider the contact system Au/Au2P3 which has been shown to exhibit as-fabricated R sub c values in the 10(exp -6) ohm cm(exp 2) range, but which fails quickly when heated. We show that the substitution of a refractory metal (W, Ta) for Au preserves the low R sub c values while preventing the destructive reactions that would normally take place in this system at high temperatures. We show, finally, that R sub c values in the 10(exp -7) ohm cm(exp 2) range can be achieved without sintering by combining the effects of In or Ga additions to Au contacts with the effects of introducing a thin Au2P3 layer at the metal-InP interface.
Robbins, Rebecca J; Leonczak, Jadwiga; Li, Julia; Johnson, J Christopher; Collins, Tom; Kwik-Uribe, Catherine; Schmitz, Harold H
2012-01-01
An international collaborative study was conducted on an HPLC method with fluorescent detection (FLD) for the determination of flavanols and procyanidins in materials containing chocolate and cocoa. The sum of the oligomeric fractions with degree of polymerization 1-10 was the determined content value. Sample materials included dark and milk chocolates, cocoa powder, cocoa liquors, and cocoa extracts. The content ranged from approximately 2 to 500 mg/g (defatted basis). Thirteen laboratories representing commercial, industrial, and academic institutions in six countries participated in the study. Fourteen samples were sent as blind duplicates to the collaborators. Results from 12 laboratories yielded repeatability relative standard deviation (RSDr) values that were below 10% for all materials analyzed, ranging from 4.17 to 9.61%. The reproducibility relative standard deviation (RSD(R)) values ranged from 5.03 to 12.9% for samples containing 8.07 to 484.7 mg/g. In one sample containing a low content of flavanols and procyanidins (approximately 2 mg/g), the RSD(R) was 17.68%. Based on these results, the method is recommended for Official First Action for the determination of flavanols and procyanidins in chocolate, cocoa liquors, powder(s), and cocoa extracts.
Water vapor radiative effects on short-wave radiation in Spain
NASA Astrophysics Data System (ADS)
Vaquero-Martínez, Javier; Antón, Manuel; Ortiz de Galisteo, José Pablo; Román, Roberto; Cachorro, Victoria E.
2018-06-01
In this work, water vapor radiative effect (WVRE) is studied by means of the Santa Barbara's Disort Radiative Transfer (SBDART) model, fed with integrated water vapor (IWV) data from 20 ground-based GPS stations in Spain. Only IWV data recorded during cloud-free days (selected using daily insolation data) were used in this study. Typically, for SZA = 60.0 ± 0.5° WVRE values are around - 82 and - 66 Wm-2 (first and third quartile), although it can reach up - 100 Wm-2 or decrease to - 39 Wm-2. A power dependence of WVRE on IWV and cosine of solar zenith angle (SZA) was found by an empirical fit. This relation is used to determine the water vapor radiative efficiency (WVEFF = ∂WVRE/∂IWV). Obtained WVEFF values range from - 9 and 0 Wm-2 mm-1 (- 2.2 and 0% mm-1 in relative terms). It is observed that WVEFF decreases as IWV increases, but also as SZA increases. On the other hand, when relative WVEFF is calculated from normalized WVRE, an increase of SZA results in an increase of relative WVEFF. Heating rates were also calculated, ranging from 0.2 Kday-1 to 1.7 Kday-1. WVRE was also calculated at top of atmosphere, where values ranged from 4 Wm-2 to 37 Wm-2.
NASA Technical Reports Server (NTRS)
Weizer, Victor G.; Fatemi, Navid S.
1991-01-01
An investigation is made into the possibility of providing low resistance contacts to shallow junction InP solar cells which do not require sintering and which do not cause device degradation even when subjected to extended annealing at elevated temperatures. We show that the addition of In to Au contacts in amounts that exceed the solid solubility limit lowers the as-fabricated (unsintered) contact resistivity (R sub c) to the 10(exp -5) ohm cm(exp 2) range. We next consider the contact system Au/Au2P3, which has been shown to exhibit as-fabricated R sub c values in the 10(exp -6) ohm cm(exp 2) range, but which fails quickly when heated. We show that the substitution of a refractory metal (W, Ta) for Au preserves the low R sub c values while preventing the destructive reactions that would normally take place in this system at high temperatures. We show, finally, that R sub c values in the 10(exp -7) ohm cm(exp 2) range can be achieved without sintering by combining the effects of In or Ga additions to Au contacts with the effects of introducing a thin Au2P3 layer at the metal-InP interface.
Vocal tract resonances in singing: The soprano voice
NASA Astrophysics Data System (ADS)
Joliveau, Elodie; Smith, John; Wolfe, Joe
2004-10-01
The vocal tract resonances of trained soprano singers were measured while they sang a range of vowels softly at different pitches. The measurements were made by broad band acoustic excitation at the mouth, which allowed the resonances of the tract to be measured simultaneously with and independently from the harmonics of the voice. At low pitch, when the lowest resonance frequency R1 exceeded f0, the values of the first two resonances R1 and R2 varied little with frequency and had values consistent with normal speech. At higher pitches, however, when f0 exceeded the value of R1 observed at low pitch, R1 increased with f0 so that R1 was approximately equal to f0. R2 also increased over this high pitch range, probably as an incidental consequence of the tuning of R1. R3 increased slightly but systematically, across the whole pitch range measured. There was no evidence that any resonances are tuned close to harmonics of the pitch frequency except for R1 at high pitch. The variations in R1 and R2 at high pitch mean that vowels move, converge, and overlap their positions on the vocal plane (R2,R1) to an extent that implies loss of intelligibility. .
Does a normal foetus really have a future of value? A reply to Marquis.
Lovering, Robert P
2005-04-01
The traditional approach to the abortion debate revolves around numerous issues, such as whether the foetus is a person, whether the foetus has rights, and more. Don Marquis suggests that this traditional approach leads to a standoff and that the abortion debate 'requires a different strategy.' Hence his 'future of value' strategy, which is summarized as follows: (1) A normal foetus has a future of value. (2) Depriving a normal foetus of a future of value imposes a misfortune on it. (3) Imposing a misfortune on a normal foetus is prima facie wrong. (4) Therefore, depriving a normal foetus of a future of value is prima facie wrong. (5) Killing a normal foetus deprives it of a future value. (6) Therefore, killing a normal foetus is prima facie wrong. In this paper, I argue that Marquis's strategy is not different since it involves the concept of person--a concept deeply rooted in the traditional approach. Specifically, I argue that futures are valuable insofar as they are not only dominated by goods of consciousness, but are experienced by psychologically continuous persons. Moreover, I argue that his strategy is not sound since premise (1) is false. Specifically, I argue that a normal foetus, at least during the first trimester, is not a person. Thus, during that stage of development it is not capable of experiencing its future as a psychologically continuous person and, hence, it does not have a future of value.
Dynamic divisive normalization predicts time-varying value coding in decision-related circuits.
Louie, Kenway; LoFaro, Thomas; Webb, Ryan; Glimcher, Paul W
2014-11-26
Normalization is a widespread neural computation, mediating divisive gain control in sensory processing and implementing a context-dependent value code in decision-related frontal and parietal cortices. Although decision-making is a dynamic process with complex temporal characteristics, most models of normalization are time-independent and little is known about the dynamic interaction of normalization and choice. Here, we show that a simple differential equation model of normalization explains the characteristic phasic-sustained pattern of cortical decision activity and predicts specific normalization dynamics: value coding during initial transients, time-varying value modulation, and delayed onset of contextual information. Empirically, we observe these predicted dynamics in saccade-related neurons in monkey lateral intraparietal cortex. Furthermore, such models naturally incorporate a time-weighted average of past activity, implementing an intrinsic reference-dependence in value coding. These results suggest that a single network mechanism can explain both transient and sustained decision activity, emphasizing the importance of a dynamic view of normalization in neural coding. Copyright © 2014 the authors 0270-6474/14/3416046-12$15.00/0.
Aging and memory: corrections for age, sex and education for three widely used memory tests.
Zappalà, G; Measso, G; Cavarzeran, F; Grigoletto, F; Lebowitz, B; Pirozzolo, F; Amaducci, L; Massari, D; Crook, T
1995-04-01
The associate learning subtest from the Wechsler Memory Scale; Benton's Visual Retention test and a Controlled Word Association Task (FAS) were administered to a random sample of normal, healthy individuals whose age ranged from 20 to 79 years, recruited within the Italian peninsula. The neuropsychological examination took place on a mobile unit and the tests were given by the same team of neuropsychologists to reduce variability among examiners. The Research Project was known as Progetto Memoria. Corrections to the scores of these tests were calculated for age, sex, and education. These corrected values will allow clinicians to screen for memory impairment with greater precision among normally aging individuals, thus improving differential diagnosis between physiologic and pathologic deterioration of cognitive functions.
Nanoparticle formulations of cisplatin for cancer therapy
Duan, Xiaopin; He, Chunbai; Kron, Stephen J.; Lin, Wenbin
2016-01-01
The genotoxic agent cisplatin, used alone or in combination with radiation and/or other chemotherapeutic agents, is an important first-line chemotherapy for a broad range of cancers. The clinical utility of cisplatin is limited both by intrinsic and acquired resistance and dose-limiting normal tissue toxicity. That cisplatin shows little selectivity for tumor versus normal tissue may be a critical factor limiting its value. To overcome the low therapeutic ratio of the free drug, macromolecular, liposomal and nanoparticle drug delivery systems have been explored toward leveraging the enhanced permeability and retention (EPR) effect and promoting delivery of cisplatin to tumors. Here, we survey recent advances in nanoparticle formulations of cisplatin, focusing on agents that show promise in preclinical or clinical settings. PMID:26848041
Using the range to calculate the coefficient of variation.
Rhiel, G Steven
2004-12-01
In this research a coefficient of variation (CVhigh-low) is calculated from the highest and lowest values in a set of data. Use of CVhigh-low when the population is normal, leptokurtic, and skewed is discussed. The statistic is the most effective when sampling from the normal distribution. With the leptokurtic distributions, CVhigh-low works well for comparing the relative variability between two or more distributions but does not provide a very "good" point estimate of the population coefficient of variation. With skewed distributions CVhigh-low works well in identifying which data set has the more relative variation but does not specify how much difference there is in the variation. It also does not provide a "good" point estimate.
Nardelli, Schuyler C; Twardowski, Michael S
2016-10-31
The relationship between absorption at 676 nm normalized to chlorophyll-a, i.e., specific absorption aph*(676), and various optical and environmental properties is examined in extensive data sets from Case I and Case II waters found globally to assess drivers of variability such as pigment packaging. A better understanding of this variability could lead to more accurate estimates of chlorophyll concentrations from in situ optical measurements that may be made autonomously. Values of aph*(676) ranged from 0.00006 to 0.0944 m2/mg Chl a across all sites studied, but converged on median and mean values (n = 563) of 0.0108 and 0.0139 m2/mg Chl a respectively, with no apparent relationship with various optical properties, latitude, coastal or open ocean environment, depth, temperature, salinity, photoadaptation, ecosystem health, or albedo. Relative consistency in aph* across such diverse water types and the full range in chlorophyll concentration suggests a single aph* may be used to estimate chlorophyll concentration from absorption measurements with better accuracy than currently thought.
Simulating magnetic resonance images based on a model of tumor growth incorporating microenvironment
NASA Astrophysics Data System (ADS)
Jackson, Pamela R.; Hawkins-Daarud, Andrea; Partridge, Savannah C.; Kinahan, Paul E.; Swanson, Kristin R.
2018-03-01
Glioblastoma (GBM), the most aggressive primary brain tumor, is primarily diagnosed and monitored using gadoliniumenhanced T1-weighted and T2-weighted (T2W) magnetic resonance imaging (MRI). Hyperintensity on T2W images is understood to correspond with vasogenic edema and infiltrating tumor cells. GBM's inherent heterogeneity and resulting non-specific MRI image features complicate assessing treatment response. To better understand treatment response, we propose creating a patient-specific untreated virtual imaging control (UVIC), which represents an individual tumor's growth if it had not been treated, for comparison with actual post-treatment images. We generated a T2W MRI UVIC by combining a patient-specific mathematical model of tumor growth with a multi-compartmental MRI signal equation. GBM growth was mathematically modeled using the previously developed Proliferation-Invasion-Hypoxia-Necrosis- Angiogenesis-Edema (PIHNA-E) model, which simulated tumor as being comprised of three cellular phenotypes: normoxic, hypoxic and necrotic cells interacting with a vasculature species, angiogenic factors and extracellular fluid. Within the PIHNA-E model, both hypoxic and normoxic cells emitted angiogenic factors, which recruited additional vessels and caused the vessels to leak, allowing fluid, or edema, to escape into the extracellular space. The model's output was spatial volume fraction maps for each glioma cell type and edema/extracellular space. Volume fraction maps and corresponding T2 values were then incorporated into a multi-compartmental Bloch signal equation to create simulated T2W images. T2 values for individual compartments were estimated from the literature and a normal volunteer. T2 maps calculated from simulated images had normal white matter, normal gray matter, and tumor tissue T2 values within range of literature values.
Ruiz de Almodóvar, José Mariano; Guirado, Damian; Isabel Núñez, María; López, Escarlata; Guerrero, Rosario; Valenzuela, María Teresa; Villalobos, Mercedes; del Moral, Rosario
2002-03-01
The purpose of this study was to determine whether the distribution of sensitivities in breast cancer patients, measured using a DNA damage assay on lymphocytes, is likely to provide sufficient discrimination to enable the reliable identification of patients with abnormal sensitivities. Radiosensitivity (x) was assessed in 226 samples of lymphocytes from unselected women with breast cancer and was quantified as the initial number of DNA double-strand breaks (dsb) induced per Gy and per DNA unit (200 Mbp). The existence of an inter-individual variation in the parameter (x) is described through the range (0.40-4.72 dsb/Gy/DNA unit) of values found, which have been fitted to the mathematical model defined by the log-normal distribution (mu = 0.42+/-0.03; sigma = 0.52+/-0.03; R(2)=0.9475). A total of 189 patients received radiotherapy after surgical treatment. Among them, we have detected 15 patients who developed severe skin reactions and we have compared their radiosensitivity values with the rest of patients treated. Our results suggest that DNA initial damage measured on lymphocytes offers an approach to predict the acute response of human normal tissues prior to radiotherapy. Values of x higher than 3.20 dsb/Gy/DNA unit theoretically should correspond to the highly radio-sensitive patients. Using the experimental results, we have calculated the strength of the test by means of the area under the receiver operator characteristic curves (A(Z)) to determine whether the radiosensitivity assay can discriminate between patients according to their radiation response. The value found (A(Z)=0.675+/-0.072) is indicative of a fair-poor discriminating capacity of the test to identify the patients with higher risk of developing a severe acute reaction during the radiotherapy treatment.
Meyts, Isabelle; Reempts, Patrick Van; Boeck, Kris De
2002-12-01
The aim of this study was to establish normal values for overnight oxygen saturation (SpO2) in healthy term infants using an oximeter which takes into account motion artifacts and to compare these to normal values collected with a previous generation oximeter not correcting for motion artifacts. We recorded overnight SpO2 in 26 term, healthy infants (median age 136 days, range 6-364 days) in the home environment using the Nellcor Symphony N 3000 pulse oximeter with an averaging time of 3 s. A sample rate of 5 s was chosen. Motion artifacts were excluded from the analysis. Data were compared with those from a previous study, using the same inclusion and exclusion criteria with the Oxford Medilog. Median (quartiles) SpO2 was 98% (97%-99%). Median percentage of study time below SpO2 94% was 0.2% (0.1%-0.7%); median percentage of study time below SpO2 90% was 0.0% (0.0%-0.01%). Median SpO2with the Oxford oximeter was 97% (96%-98%); percentage of study time below SpO2 94% was 8% (2%-14%); percentage of study time below SpO2 90% was 2% (0%-4%). These data were compared with the Nellcor Symphony data: differences in median SpO2 were significant ( P<0.05); differences in percentage of time below SpO2 94% and 90% were also statistically significant ( P<0.001). we established normal values of oxygen saturation in healthy term infants using the Nellcor Symphony 3000 pulse oximeter. Care should be taken in interpreting values obtained with different types of pulse oximeters.
The effect of physical activity on bone turnover in young adults.
Franck, H; Beuker, F; Gurk, S
1991-01-01
Physical activity has been suggested as one of the determinants of bone turnover and to prevent the involutional age related bone loss. However, the degree to which physical exercise is necessary to induce changes in bone turnover and calciotropic hormones have been widely discussed (Williams et al., 1984; Cook et al., 1987; Smith et al., 1985). The aim of this study was to examine the rate of bone formation measured by osteocalcin in 56 healthy volunteers before and after 4 and 8 weeks of physical exercise (PE) and its dependence on various parameters of calcium and phosphate metabolism. The studied group consisting of 44 men and 12 women, mean age 24.8 and 24.3 years, respectively, performed a standardized physical training of 8 weeks. Mean serum osteocalcin levels were significantly (p less than 0.01) reduced after 4 weeks (men: 2.26 +/- 1.8 ng/ml; women: 0.94 +/- 1.6 ng/ml) compared to the values before PE (men: 4.01 +/- 2.18 ng/ml; women: 1.69 +/- 1.7 ng/ml) and returned to normal values after 8 weeks. Similarly, magnesium levels (0.82 mmol/l) decreased significantly (p less than 0.01) after 4 weeks of PE (0.79 mmol/l), returning to normal values after 8 weeks. Concomitantly, there was only a slight, but significant fall of serum calcium from 2.48 +/- 0.07 to 2.45 +/- 0.07 returning to initial values again. Furthermore, serum phosphate increased slightly in men from 1.01 mmol/l to 1.13 and 1.15 mmol/l after 4 and 8 weeks, respectively. In contrast, alkaline phosphatase and serum creatinine remained in the normal range.(ABSTRACT TRUNCATED AT 250 WORDS)
NASA Astrophysics Data System (ADS)
Li, Zongchao; Chen, Xueliang; Gao, Mengtan; Jiang, Han; Li, Tiefei
2017-03-01
Earthquake engineering parameters are very important in the engineering field, especially engineering anti-seismic design and earthquake disaster prevention. In this study, we focus on simulating earthquake engineering parameters by the empirical Green's function method. The simulated earthquake (MJMA6.5) occurred in Kyushu, Japan, 1997. Horizontal ground motion is separated as fault parallel and fault normal, in order to assess characteristics of two new direction components. Broadband frequency range of ground motion simulation is from 0.1 to 20 Hz. Through comparing observed parameters and synthetic parameters, we analyzed distribution characteristics of earthquake engineering parameters. From the comparison, the simulated waveform has high similarity with the observed waveform. We found the following. (1) Near-field PGA attenuates radically all around with strip radiation patterns in fault parallel while radiation patterns of fault normal is circular; PGV has a good similarity between observed record and synthetic record, but has different distribution characteristic in different components. (2) Rupture direction and terrain have a large influence on 90 % significant duration. (3) Arias Intensity is attenuating with increasing epicenter distance. Observed values have a high similarity with synthetic values. (4) Predominant period is very different in the part of Kyushu in fault normal. It is affected greatly by site conditions. (5) Most parameters have good reference values where the hypo-central is less than 35 km. (6) The GOF values of all these parameters are generally higher than 45 which means a good result according to Olsen's classification criterion. Not all parameters can fit well. Given these synthetic ground motion parameters, seismic hazard analysis can be performed and earthquake disaster analysis can be conducted in future urban planning.
NASA Astrophysics Data System (ADS)
Thomas, M. A.
2016-12-01
The Waste Isolation Pilot Plant (WIPP) is the only deep geological repository for transuranic waste in the United States. As the Science Advisor for the WIPP, Sandia National Laboratories annually evaluates site data against trigger values (TVs), metrics whose violation is indicative of conditions that may impact long-term repository performance. This study focuses on a groundwater-quality dataset used to redesign a TV for the Culebra Dolomite Member (Culebra) of the Permian-age Rustler Formation. Prior to this study, a TV violation occurred if the concentration of a major ion fell outside a range defined as the mean +/- two standard deviations. The ranges were thought to denote conditions that 95% of future values would fall within. Groundwater-quality data used in evaluating compliance, however, are rarely normally distributed. To create a more robust Culebra groundwater-quality TV, this study employed the randomization test, a non-parametric permutation method. Recent groundwater compositions considered TV violations under the original ion concentration ranges are now interpreted as false positives in light of the insignificant p-values calculated with the randomization test. This work highlights that the normality assumption can weaken as the size of a groundwater-quality dataset grows over time. Non-parametric permutation methods are an attractive option because no assumption about the statistical distribution is required and calculating all combinations of the data is an increasingly tractable problem with modern workstations. Sandia National Laboratories is a multi-program laboratory managed and operated by Sandia Corporation, a wholly owned subsidiary of Lockheed Martin Corporation, for the U.S. Department of Energy's National Nuclear Security Administration under contract DE-AC04-94AL85000. This research is funded by WIPP programs administered by the Office of Environmental Management (EM) of the U.S. Department of Energy. SAND2016-7306A
Lovell, David P; Fellows, Mick; Marchetti, Francesco; Christiansen, Joan; Elhajouji, Azeddine; Hashimoto, Kiyohiro; Kasamoto, Sawako; Li, Yan; Masayasu, Ozaki; Moore, Martha M; Schuler, Maik; Smith, Robert; Stankowski, Leon F; Tanaka, Jin; Tanir, Jennifer Y; Thybaud, Veronique; Van Goethem, Freddy; Whitwell, James
2018-01-01
The recent revisions of the Organisation for Economic Co-operation and Development (OECD) genetic toxicology test guidelines emphasize the importance of historical negative controls both for data quality and interpretation. The goal of a HESI Genetic Toxicology Technical Committee (GTTC) workgroup was to collect data from participating laboratories and to conduct a statistical analysis to understand and publish the range of values that are normally seen in experienced laboratories using TK6 cells to conduct the in vitro micronucleus assay. Data from negative control samples from in vitro micronucleus assays using TK6 cells from 13 laboratories were collected using a standard collection form. Although in some cases statistically significant differences can be seen within laboratories for different test conditions, they were very small. The mean incidence of micronucleated cells/1000 cells ranged from 3.2/1000 to 13.8/1000. These almost four-fold differences in micronucleus levels cannot be explained by differences in scoring method, presence or absence of exogenous metabolic activation (S9), length of treatment, presence or absence of cytochalasin B or different solvents used as vehicles. The range of means from the four laboratories using flow cytometry methods (3.7-fold: 3.5-12.9 micronucleated cells/1000 cells) was similar to that from the nine laboratories using other scoring methods (4.3-fold: 3.2-13.8 micronucleated cells/1000 cells). No laboratory could be identified as an outlier or as showing unacceptably high variability. Quality Control (QC) methods applied to analyse the intra-laboratory variability showed that there was evidence of inter-experimental variability greater than would be expected by chance (i.e. over-dispersion). However, in general, this was low. This study demonstrates the value of QC methods in helping to analyse the reproducibility of results, building up a 'normal' range of values, and as an aid to identify variability within a laboratory in order to implement processes to maintain and improve uniformity. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.
Median and ulnar neuropathies in university guitarists.
Kennedy, Rachel H; Hutcherson, Kimberly J; Kain, Jennifer B; Phillips, Alicia L; Halle, John S; Greathouse, David G
2006-02-01
Descriptive study. To determine the presence of median and ulnar neuropathies in both upper extremities of university guitarists. Peripheral nerve entrapment syndromes of the upper extremities are well documented in musicians. Guitarists and plucked-string musicians are at risk for entrapment neuropathies in the upper extremities and are prone to mild neurologic deficits. Twenty-four volunteer male and female guitarists (age range, 18-26 years) were recruited from the Belmont University School of Music and the Vanderbilt University Blair School of Music. Individuals were excluded if they were pregnant or had a history of recent upper extremity or neck injury. Subjects completed a history form, were interviewed, and underwent a physical examination. Nerve conduction status of the median and ulnar nerves of both upper extremities was obtained by performing motor, sensory, and F-wave (central) nerve conduction studies. Descriptive statistics of the nerve conduction study variables were computed using Microsoft Excel. Six subjects had positive findings on provocative testing of the median and ulnar nerves. Otherwise, these guitarists had normal upper extremity neural and musculoskeletal function based on the history and physical examinations. When comparing the subjects' nerve conduction study values with a chart of normal nerve conduction studies values, 2 subjects had prolonged distal motor latencies (DMLs) of the left median nerve of 4.3 and 4.7 milliseconds (normal, < 4.2 milliseconds). Prolonged DMLs are compatible with median neuropathy at or distal to the wrist. Otherwise, all electrophysiological variables were within normal limits for motor, sensory, and F-wave (central) values. However, comparison studies of median and ulnar motor latencies in the same hand demonstrated prolonged differences of greater than 1.0 milliseconds that affected the median nerve in 2 additional subjects, and identified contralateral limb involvement in a subject with a prolonged distal latency. The other 20 subjects demonstrated normal comparison studies of the median and ulnar nerves in both upper extremities. In this descriptive study of a population of 24 university guitarists, 4 musicians (17%) were found to have electrophysiologic evidence of median neuropathy at or distal to the wrist or carpal tunnel syndrome. Ulnar nerve electrophysiological function was within normal limits for all subjects examined.
Segregation of Impurities in Directionally Solidified Silicon
NASA Technical Reports Server (NTRS)
Ravishankar, P. S.; Younghouse, L. B.
1984-01-01
Hall measurements and four-point probe resistivity measurements are used to determine the concentration profile of boron and iron in doped semi-conductor silicon ingots grown by the Bridgman technique. The concentration profiles are fitted to the normal segregation equation and the effective segregation coefficient, K sub eff, is calculated. The average value of K sub eff, is 0.803 for boron. For iron, K sub eff, is concentration dependent and is in the range 0.00008 to 0.00012.
Kynol/Nomex Fabrics for Fire Retardant Shipboard Utility Uniforms
1988-06-01
changes shade permanentlj" from grey to black. The activation temperature of each set ranged from 220 F to 2800F in increments of 100F. The response of the...temperature value. When a tape reaches its activation temperature it changes shade permanent l from grey to black. The activation temperature of each...are normally only available in their natural gold color, to a suitable blue shade . g. Potential cost of Kynol/Nomex uniforms versus the FRT cotton
DOE Office of Scientific and Technical Information (OSTI.GOV)
Damilakis, J; Stratakis, J; Solomou, G
Purpose: It is well known that pacemaker implantation is sometimes needed in pregnant patients with symptomatic bradycardia. To our knowledge, there is no reported experience regarding radiation doses to the unborn child resulting from fluoroscopy during pacemaker implantation. The purpose of the current study was to develop a method for estimating embryo/fetus dose from fluoroscopically guided pacemaker implantation procedures performed on pregnant patients during all trimesters of gestation. Methods: The Monte Carlo N-Particle (MCNP) radiation transport code was employed in this study. Three mathematical anthropomorphic phantoms representing the average pregnant patient at the first, second and third trimesters of gestationmore » were generated using Bodybuilder software (White Rock science, White Rock, NM). The normalized embryo/fetus dose from the posteroanterior (PA), the 30° left-anterior oblique (LAO) and the 30° right-anterior oblique (RAO) projections were calculated for a wide range of kVp (50–120 kVp) and total filtration values (2.5–9.0 mm Al). Results: The results consist of radiation doses normalized to a) entrance skin dose (ESD) and b) dose area product (DAP) so that the dose to the unborn child from any fluoroscopic technique and x-ray device used can be calculated. ESD normalized doses ranged from 0.008 (PA, first trimester) to 2.519 μGy/mGy (RAO, third trimester). DAP normalized doses ranged from 0.051 (PA, first trimester) to 12.852 μGy/Gycm2 (RAO, third trimester). Conclusion: Embryo/fetus doses from fluoroscopically guided pacemaker implantation procedures performed on pregnant patients during all stages of gestation can be estimated using the method developed in this study. This study was supported by the Greek Ministry of Education and Religious Affairs, General Secretariat for Research and Technology, Operational Program ‘Education and Lifelong Learning’, ARISTIA (Research project: CONCERT)« less
Galanti, Giorgio; Toncelli, Loira; Del Furia, Francesca; Stefani, Laura; Cappelli, Brunello; De Luca, Alessio; Vono, Maria Concetta Roberta
2009-01-01
Background Transthoracic echocardiography left ventricular wall thickness is often increased in master athletes and it results by intense physical training. Left Ventricular Hypertrophy can also be due to a constant pressure overload. Conventional Pulsed Wave (PW) Doppler analysis of diastolic function sometimes fails to distinguish physiological from pathological LVH. The aim of this study is to evaluate the role of Pulsed Wave Tissue Doppler Imaging in differentiating pathological from physiological LVH in the middle-aged population. Methods we selected a group of 80 master athletes, a group of 80 sedentary subjects with essential hypertension and an apparent normal diastolic function at standard PW Doppler analysis. The two groups were comparable for increased left ventricular wall thickness and mass index (134.4 ± 19.7 vs 134.5 ± 22.1 gr/m2; p > .05). Diastolic function indexes using the PW technique were in the normal range for both. Results Pulsed Wave TDI study of diastolic function immediately distinguished the two groups. While in master athletes the diastolic TDI-derived parameters remained within normal range (E' 9.4 ± 3.1 cm/sec; E/E' 7.8 ± 2.1), in the hypertensive group these parameters were found to be constantly altered, with mean values and variation ranges always outside normal validated limits (E' 7.2 ± 2.4 cm/sec; E/E' 10.6 ± 3.2), and with E' and E/E' statistically different in the two groups (p < .001). Conclusion Our study showed that the TDI technique can be an easy and validated method to assess diastolic function in differentiating normal from pseudonormal diastolic patterns and it can distinguish physiological from pathological LVH emphasizing the eligibility certification required by legal medical legislation as in Italy. PMID:19845938
Superconducting properties of NbN film, bridge and meanders
NASA Astrophysics Data System (ADS)
Joshi, Lalit M.; Verma, Apoorva; Gupta, Anurag; Rout, P. K.; Husale, Sudhir; Budhani, R. C.
2018-05-01
The transport properties of superconducting NbN nanostructures in the form of thin film, bridge of width (w) = 50 μm and three meanders of w = 500, 250 and 100 nm have been investigated by resistance (R) measurements in temperature (T) range = 2 -300 K and magnetic field (B) range = 0 - 7 Tesla. The nanostructuring was carried out using Focused Ion Beam (FIB) milling. Reduction of sample width results in significant changes in the normal and superconducting state properties. For instance, the observed metallic behavior in the thin film sample is lost and the normal state resistance increases drastically from 2.4 Ω to 418 kΩ for the 100 nm meander. In the superconducting state, the value of critical temperature Tc (upper critical field Bc2 at T = 0 K) reduces gradually with width reduction, it changes from 13.15 K (42.8 Tesla) in the case of thin film sample to 5.7 K (12.7 Tesla) for the 100 nm meander sample. The superconducting transitions are found to get broader for the bridge sample and the meanders additionally show low-temperature resistive tails. In case of all the samples with reduced width, the transition onsets are found to be rounded at surprisingly high values of T ˜ 25 K >> Tc. These results are discussed in terms of the possible effects of FIB processing and weak localization in our samples.
Diniz, Anaemilia das Neves; Pessoa, Gerson Tavares; da Silva Moura, Laecio; de Sousa, André Braga; Sousa, Francisco das Chagas Araújo; de Sá Rodrigues, Renan Paraguassu; da Silva Barbosa, Maria Angélica Parente; de Almeida, Hatawa Melo; Freire, Larisse Danielle Silva; Sanches, Marina Pinto; Júnior, Antônio Augusto Nascimento Machado; Guerra, Porfírio Candanedo; Neves, Willams Costa; de Sousa, João Macedo; Bolfer, Luiz; Giglio, Robson Fortes; Alves, Flávio Ribeiro
2017-06-01
The black-rumped agouti ( Dasyprocta prymnolopha , Wagler 1831) is currently under intense ecologic pressure, which has resulted in its disappearance from some regions of Brazil. Echocardiography is widely used in veterinary medicine but it is not yet part of the clinical routine for wild animals. The objective of the present study was to assess the applicability of the echocardiographic exam in nonanesthetized agouti and to establish normal reference values for echocardiographic measurements in bidimensional mode (2D), M-mode, and Doppler for this species, and a lead II electrocardiogram was simultaneously recorded. Twenty agouti were used in this study. All the echocardiographic measurements were positively correlated with weight (P < 0.05), and there were no significant differences between sexes (P > 0.05). Blood flow velocities in the pulmonary and aortic artery ranged from 67.32-71.28 cm/sec and 79.22-101.84 cm/sec, respectively. The isovolumic relaxation time was assessed in all the animals and ranged from 38.5 to 56.6 ms. The maximum value for the nonfused E and A waves and the Et and At waves was 158 beats/min for both. The results obtained for the morphologic and heart hemodynamic measurements can guide future studies and help in the clinical management of these animals in captivity.
Daudu, Oluremi Martha; Sani, Rahamatu Usman; Adedibu, Iyetunde Ifeyori; Ademu, Lawrence Anebi; Bawa, Gideon Shaibu; Olugbemi, Taiye Sunday
2014-01-01
A total of thirty-five mixed breed (35) rabbits of average weight of 700 g aged 5-6 weeks were allocated to seven treatments in a completely randomised design to investigate the effect of sweet orange fruit waste (SOFW) and acidomix acidifier on haematology and serum chemistry. The diets were 0% SOFW, 10% SOFW with 0.5% acidomix, 10% SOFW with 0.7 acidomix, 15% SOFW with 0.5% acidifier, 15% SOFW with 0.7% acidifier, 20% SOFW with 0.5% acidifier, and 20% SOFW with 0.7% acidifier. Blood samples were analyzed for haemoglobin (hb) concentration, white blood cells (WBC), red blood cells (RBC), differential WBC count (lymphocyte, basophil, eosinophil, monocyte, and neutrophil), alanine amino transferase (ALT), alkaline phosphatase (ALP), aspartate amino transferase (AST), total protein, albumin, and globulin. There was no interaction between SOFW and acidifier for the haematological and most of the serum chemistry parameters but significant difference was observed in ALT; however the values were within the normal range. SOFW had no significant effect on all haematological and serum chemistry parameters. Acidomix had significant effect (P < 0.05) on haemoglobin concentration; rabbits fed 0.5% acidomix diets had higher values which were within the normal range. It is therefore concluded that SOFW with acidifier up to 20% had no detrimental effect on serum chemistry and haematology. PMID:26464931
NASA Technical Reports Server (NTRS)
SHARDANAND; Rao, A. D. P.
1977-01-01
The laboratory measurements of absolute Rayleigh scattering cross sections as a function wavelength are reported for gas molecules He, Ne, Ar, N2, H2, O2, CO2, CH4 and for vapors of most commonly used freons CCl2F2, CBrF3, CF4, and CHClf2. These cross sections are determined from the measurements of photon scattering at an angle of 54 deg 44 min which yield the absolute values independent of the value of normal depolarization ratios. The present results show that in the spectral range 6943-3638A deg, the values of the Rayleigh scattering cross section can be extrapolated from one wavelength to the other using 1/lambda (4) law without knowing the values of the polarizabilities. However, such an extrapolation can not be done in the region of shorter wavelengths.
The softest sound levels of the human voice in normal subjects.
Šrámková, Hana; Granqvist, Svante; Herbst, Christian T; Švec, Jan G
2015-01-01
Accurate measurement of the softest sound levels of phonation presents technical and methodological challenges. This study aimed at (1) reliably obtaining normative data on sustained softest sound levels for the vowel [a:] at comfortable pitch; (2) comparing the results for different frequency and time weighting methods; and (3) refining the Union of European Phoniatricians' recommendation on allowed background noise levels for scientific and equipment manufacturers' purposes. Eighty healthy untrained participants (40 females, 40 males) were investigated in quiet rooms using a head-mounted microphone and a sound level meter at 30 cm distance. The one-second-equivalent sound levels were more stable and more representative for evaluating the softest sustained phonations than the fast-time-weighted levels. At 30 cm, these levels were in the range of 48-61 dB(C)/41-53 dB(A) for females and 49 - 64 dB(C)/35-53 dB(A) for males (5% to 95% quantile range). These ranges may serve as reference data in evaluating vocal normality. In order to reach a signal-to-noise ratio of at least 10 dB for more than 95% of the normal population, the background noise should be below 25 dB(A) and 38 dB(C), respectively, for the softest phonation measurements at 30 cm distance. For the A-weighting, this is 15 dB lower than the previously recommended value.
NASA Astrophysics Data System (ADS)
Sathian, Sarith. P.; Kurian, Job
2005-05-01
This paper presents the results of the Laser Reflection Method (LRM) for the determination of shear stress due to impingement of low-density free jets on flat plate. For thin oil film moving under the action of aerodynamic boundary layer the shear stress at the air-oil interface is equal to the shear stress between the surface and air. A direct and dynamic measurement of the oil film slope is measured using a position sensing detector (PSD). The thinning rate of oil film is directly measured which is the major advantage of the LRM over LISF method. From the oil film slope history, direct calculation of the shear stress is done using a three-point formula. For the full range of experiment conditions Knudsen numbers varied till the continuum limit of the transition regime. The shear stress values for low-density flows in the transition regime are thus obtained using LRM and the measured values of shear show fair agreement with those obtained by other methods. Results of the normal pressure measurements on a flat plate in low-density jets by using thermistors as pressure sensors are also presented in the paper. The normal pressure profiles obtained show the characteristic features of Newtonian impact theory for hypersonic flows.
Dietary Management of Hyperthyroidism in a Dog.
Looney, Andrea; Wakshlag, Joseph
An 8 yr old female spayed golden retriever presented for a routine exam during which ventral cervical soft tissue masses were identified. History included weight loss, increased activity and appetite, gagging, and occasional diarrhea. Exam findings included a body condition score of 4/9 and palpable ventral cervical nodules. A serum thyroxine (T4) value was 8.0 ug/dL (normal = 0.8-3.5ug/dL). Doppler systolic blood pressure readings ranged from 200-210 mmHg (normal systolic blood pressure <150 mmHg). The diagnosis was hyperthyroidism due to active thyroid masses. Due to financial constraints, the owner elected conservative management. Initial treatment with methimazole resulted in a decreased T4 value of 5.0 ug/dL at approximately 4 mo after initiation of treatment. A commercially available iodine-restricted feline diet was fed and this resulted in further reduction in serum T4 levels, improved sleeping cycles, reduced anxiety, and reduced systolic blood pressure. A temporary suspension of iodine-restricted feline diet for 2 mo resulted in increases in serum T4 concentrations, which, subsequently, decreased with re-introduction of the diet. Roughly 10 mo after initiation of the therapeutic diet and 16 mo after intial diagnosis, the dog remains relatively normal clinically despite active growing cervical masses with T4 concentration of 2.3 ug/dL.
Friction and lubrication of pleural tissues.
D'Angelo, Edgardo; Loring, Stephen H; Gioia, Magda E; Pecchiari, Matteo; Moscheni, Claudia
2004-08-20
The frictional behaviour of rabbit's visceral pleura sliding against parietal pleura was assessed in vitro while oscillating at physiological velocities and amplitudes under physiological normal forces. For sliding velocities up to 3 cm s(-1) and normal compressive loads up to 12 cm H2O, the average value of the coefficient of kinetic friction (mu) was constant at 0.019 +/- 0.002 (S.E.) with pleural liquid as lubricant. With Ringer-bicarbonate solution, mu was still constant, but significantly increased (Deltamu = 0.008 +/- 0.001; P < 0.001). Under these conditions, no damage of the sliding pleural surfaces was found on light and electron microscopy. Additional measurements, performed also on peritoneum, showed that changes in nominal contact area or strain of the mesothelia, temperature in the range 19-39 degrees C, and prolonged sliding did not affect mu. Gentle application of filter paper increased mu approximately 10-fold and irreversibly, suggesting alteration of the mesothelia. With packed the red blood cells (RBC) between the sliding mesothelia, mu increased appreciably but reversibly on removal of RBC suspension, whilst no ruptures of RBC occurred. In conclusion, the results indicate a low value of sliding friction in pleural tissues, partly related to the characteristics of the pleural liquid, and show that friction is independent of velocity, normal load, and nominal contact area, consistent with boundary lubrication.
Sullivan, Kathleen E; Fleming, Greg; Terrell, Scott; Smith, Dustin; Ridgley, Frank; Valdes, Eduardo V
2014-12-01
Recent issues surrounding captive amphibians are often nutritionally related problems, such as hypovitaminosis A. Although supplementation of frogs with vitamin A is a topic of investigation, the underlying issue is understanding vitamin A metabolism in amphibian species. To develop a range of "normal" vitamin A concentrations for captive amphibians, baseline vitamin A concentrations must be established in wild amphibian species. In this study, two species, Cuban tree frogs (Osteopilus septentrionalis; n = 59) and marine toads (Rhinella marina; n = 20) were collected from the wild as part of an invasive species control program at Zoo Miami, Miami, Florida. Serum, liver, and whole body samples were analyzed for vitamin A content. The Cuban tree frogs showed higher concentrations on average of vitamin A in serum (82.8 ppb), liver (248.3 IU/g), and whole body (5474.7 IU/kg) samples compared with marine toads (60.1 ppb; 105.3 IU/g; 940.7 IU/kg, respectively), but differences were not significant (P = 0.22). What can be considered "normal" values of vitamin A concentrations across different amphibian species requires further investigation. Although all amphibians collected in this study appeared healthy, a larger sample size of animals, with known health histories and diets, may provide stronger evidence of normal expectations.
Kraut, Jeffrey A; Nagami, Glenn T
2013-11-01
The serum anion gap has been utilized to identify errors in the measurement of electrolytes, to detect paraproteins, and, most relevant to the nephrologist, to evaluate patients with suspected acid-base disorders. In regard to the latter purpose, traditionally an increased anion gap is identified when it exceeds the upper limit of normal for a particular clinical laboratory measurement. However, because there is a wide range of normal values (often 8-10 mEq/L), an increase in anion concentration can be present in the absence of an increased anion gap. In addition, the type of retained anion can affect the magnitude of the increase in anion gap relative to change in serum [HCO3(-)] being greater with lactic acidosis compared with ketoacidosis. This review examines the methods of calculation of the serum anion gap in textbooks and published literature, the effect of perturbations other than changes in acid-base balance, and its effectiveness in identifying mild and more severe disturbances in acid-base balance. Limitations of the present methods of determining the normal anion gap and change in the anion gap are highlighted. The possibility of identifying the baseline value for individuals to optimize the use of the calculation in the detection of metabolic acidosis is suggested.
Univariate normalization of bispectrum using Hölder's inequality.
Shahbazi, Forooz; Ewald, Arne; Nolte, Guido
2014-08-15
Considering that many biological systems including the brain are complex non-linear systems, suitable methods capable of detecting these non-linearities are required to study the dynamical properties of these systems. One of these tools is the third order cummulant or cross-bispectrum, which is a measure of interfrequency interactions between three signals. For convenient interpretation, interaction measures are most commonly normalized to be independent of constant scales of the signals such that its absolute values are bounded by one, with this limit reflecting perfect coupling. Although many different normalization factors for cross-bispectra were suggested in the literature these either do not lead to bounded measures or are themselves dependent on the coupling and not only on the scale of the signals. In this paper we suggest a normalization factor which is univariate, i.e., dependent only on the amplitude of each signal and not on the interactions between signals. Using a generalization of Hölder's inequality it is proven that the absolute value of this univariate bicoherence is bounded by zero and one. We compared three widely used normalizations to the univariate normalization concerning the significance of bicoherence values gained from resampling tests. Bicoherence values are calculated from real EEG data recorded in an eyes closed experiment from 10 subjects. The results show slightly more significant values for the univariate normalization but in general, the differences are very small or even vanishing in some subjects. Therefore, we conclude that the normalization factor does not play an important role in the bicoherence values with regard to statistical power, although a univariate normalization is the only normalization factor which fulfills all the required conditions of a proper normalization. Copyright © 2014 Elsevier B.V. All rights reserved.