Sample records for note precision levels

  1. Analysing playing using the note-time playing path.

    PubMed

    de Graaff, Deborah L E; Schubert, Emery

    2011-03-01

    This article introduces a new method of data analysis that represents the playing of written music as a graph. The method, inspired by Miklaszewski, charts low-level note timings from a sound recording of a single-line instrument using high-precision audio-to-MIDI conversion software. Note onset times of pitch sequences are then plotted against the score-predicted timings to produce a Note-Time Playing Path (NTPP). The score-predicted onset time of each sequentially performed note (horizontal axis) unfolds in performed time down the page (vertical axis). NTPPs provide a visualisation that shows (1) tempo variations, (2) repetitive practice behaviours, (3) segmenting of material, (4) precise note time positions, and (5) time spent on playing or not playing. The NTPP can provide significant new insights into behaviour and cognition of music performance and may also be used to complement established traditional approaches such as think-alouds, interviews, and video coding.

  2. Increasing Endurance by Building Fluency: Precision Teaching Attention Span.

    ERIC Educational Resources Information Center

    Binder, Carl; And Others

    1990-01-01

    Precision teaching techniques can be used to chart students' attention span or endurance. Individual differences in attention span can then be better understood and dealt with effectively. The effects of performance duration on performance level, on error rates, and on learning rates are discussed. Implications for classroom practice are noted.…

  3. Search Filter Precision Can Be Improved By NOTing Out Irrelevant Content

    PubMed Central

    Wilczynski, Nancy L.; McKibbon, K. Ann; Haynes, R. Brian

    2011-01-01

    Background: Most methodologic search filters developed for use in large electronic databases such as MEDLINE have low precision. One method that has been proposed but not tested for improving precision is NOTing out irrelevant content. Objective: To determine if search filter precision can be improved by NOTing out the text words and index terms assigned to those articles that are retrieved but are off-target. Design: Analytic survey. Methods: NOTing out unique terms in off-target articles and testing search filter performance in the Clinical Hedges Database. Main Outcome Measures: Sensitivity, specificity, precision and number needed to read (NNR). Results: For all purpose categories (diagnosis, prognosis and etiology) except treatment and for all databases (MEDLINE, EMBASE, CINAHL and PsycINFO), constructing search filters that NOTed out irrelevant content resulted in substantive improvements in NNR (over four-fold for some purpose categories and databases). Conclusion: Search filter precision can be improved by NOTing out irrelevant content. PMID:22195215

  4. Intelligent Automatic Classification of True and Counterfeit Notes Based on Spectrum Analysis

    NASA Astrophysics Data System (ADS)

    Matsunaga, Shohei; Omatu, Sigeru; Kosaka, Toshohisa

    The purpose of this paper is to classify bank notes into “true” or “counterfeit” ones faster and more precisely compared with a conventional method. We note that thin lines are represented by direct lines in the images of true notes while they are represented in the counterfeit notes by dotted lines. This is due to properties of dot printers or scanner levels. To use the properties, we propose two method to classify a note into true or counterfeited one by checking whether there exist thin lines or dotted lines of the note. First, we use Fourier transform of the note to find quantity of features for classification and we classify a note into true or counterfeit one by using the features by Fourier transform. Then we propose a classification method by using wavelet transform in place of Fourier transform. Finally, some classification results are illustrated to show the effectiveness of the proposed methods.

  5. Precise auditory-vocal mirroring in neurons for learned vocal communication.

    PubMed

    Prather, J F; Peters, S; Nowicki, S; Mooney, R

    2008-01-17

    Brain mechanisms for communication must establish a correspondence between sensory and motor codes used to represent the signal. One idea is that this correspondence is established at the level of single neurons that are active when the individual performs a particular gesture or observes a similar gesture performed by another individual. Although neurons that display a precise auditory-vocal correspondence could facilitate vocal communication, they have yet to be identified. Here we report that a certain class of neurons in the swamp sparrow forebrain displays a precise auditory-vocal correspondence. We show that these neurons respond in a temporally precise fashion to auditory presentation of certain note sequences in this songbird's repertoire and to similar note sequences in other birds' songs. These neurons display nearly identical patterns of activity when the bird sings the same sequence, and disrupting auditory feedback does not alter this singing-related activity, indicating it is motor in nature. Furthermore, these neurons innervate striatal structures important for song learning, raising the possibility that singing-related activity in these cells is compared to auditory feedback to guide vocal learning.

  6. Supertitrations: High-Precision Methods.

    ERIC Educational Resources Information Center

    Guenther, W. B.

    1988-01-01

    Offers challenging work at a higher level of technique than most students meet in elementary laboratory work. Uses a combined weight and volumetric sequence not shown in textbooks. Notes modern rapid balances help lower evaporation loss during weighings. Discusses the balance, weights, and buoyancy considerations. (MVL)

  7. Corporate Consolidation: An Event Study of Historic Stock Prices in the Defense Aerospace Industry

    DTIC Science & Technology

    2009-12-01

    1994 Raytheon Xyplex Inc 1/3/1995 Boeing Precision Gear 4/3/1995 Raytheon Raytheon E-Systems Inc 6/30/1995 Raytheon Litwin Engineers & Construction...Acquirer 6/30/1995 Litwin Engineers & Construction Raytheon Arithmetic Return Logarithmic Return Note: * is significant at the 5% level 90

  8. Detecting clinically relevant new information in clinical notes across specialties and settings.

    PubMed

    Zhang, Rui; Pakhomov, Serguei V S; Arsoniadis, Elliot G; Lee, Janet T; Wang, Yan; Melton, Genevieve B

    2017-07-05

    Automated methods for identifying clinically relevant new versus redundant information in electronic health record (EHR) clinical notes is useful for clinicians and researchers involved in patient care and clinical research, respectively. We evaluated methods to automatically identify clinically relevant new information in clinical notes, and compared the quantity of redundant information across specialties and clinical settings. Statistical language models augmented with semantic similarity measures were evaluated as a means to detect and quantify clinically relevant new and redundant information over longitudinal clinical notes for a given patient. A corpus of 591 progress notes over 40 inpatient admissions was annotated for new information longitudinally by physicians to generate a reference standard. Note redundancy between various specialties was evaluated on 71,021 outpatient notes and 64,695 inpatient notes from 500 solid organ transplant patients (April 2015 through August 2015). Our best method achieved at best performance of 0.87 recall, 0.62 precision, and 0.72 F-measure. Addition of semantic similarity metrics compared to baseline improved recall but otherwise resulted in similar performance. While outpatient and inpatient notes had relatively similar levels of high redundancy (61% and 68%, respectively), redundancy differed by author specialty with mean redundancy of 75%, 66%, 57%, and 55% observed in pediatric, internal medicine, psychiatry and surgical notes, respectively. Automated techniques with statistical language models for detecting redundant versus clinically relevant new information in clinical notes do not improve with the addition of semantic similarity measures. While levels of redundancy seem relatively similar in the inpatient and ambulatory settings in the Fairview Health Services, clinical note redundancy appears to vary significantly with different medical specialties.

  9. Note: High precision measurements using high frequency gigahertz signals

    NASA Astrophysics Data System (ADS)

    Jin, Aohan; Fu, Siyuan; Sakurai, Atsunori; Liu, Liang; Edman, Fredrik; Pullerits, Tõnu; Öwall, Viktor; Karki, Khadga Jung

    2014-12-01

    Generalized lock-in amplifiers use digital cavities with Q-factors as high as 5 × 108 to measure signals with very high precision. In this Note, we show that generalized lock-in amplifiers can be used to analyze microwave (giga-hertz) signals with a precision of few tens of hertz. We propose that the physical changes in the medium of propagation can be measured precisely by the ultra-high precision measurement of the signal. We provide evidence to our proposition by verifying the Newton's law of cooling by measuring the effect of change in temperature on the phase and amplitude of the signals propagating through two calibrated cables. The technique could be used to precisely measure different physical properties of the propagation medium, for example, the change in length, resistance, etc. Real time implementation of the technique can open up new methodologies of in situ virtual metrology in material design.

  10. Comparison of precision and speed in laparoscopic and robot-assisted surgical task performance.

    PubMed

    Zihni, Ahmed; Gerull, William D; Cavallo, Jaime A; Ge, Tianjia; Ray, Shuddhadeb; Chiu, Jason; Brunt, L Michael; Awad, Michael M

    2018-03-01

    Robotic platforms have the potential advantage of providing additional dexterity and precision to surgeons while performing complex laparoscopic tasks, especially for those in training. Few quantitative evaluations of surgical task performance comparing laparoscopic and robotic platforms among surgeons of varying experience levels have been done. We compared measures of quality and efficiency of Fundamentals of Laparoscopic Surgery task performance on these platforms in novices and experienced laparoscopic and robotic surgeons. Fourteen novices, 12 expert laparoscopic surgeons (>100 laparoscopic procedures performed, no robotics experience), and five expert robotic surgeons (>25 robotic procedures performed) performed three Fundamentals of Laparoscopic Surgery tasks on both laparoscopic and robotic platforms: peg transfer (PT), pattern cutting (PC), and intracorporeal suturing. All tasks were repeated three times by each subject on each platform in a randomized order. Mean completion times and mean errors per trial (EPT) were calculated for each task on both platforms. Results were compared using Student's t-test (P < 0.05 considered statistically significant). Among novices, greater errors were noted during laparoscopic PC (Lap 2.21 versus Robot 0.88 EPT, P < 0.001). Among expert laparoscopists, greater errors were noted during laparoscopic PT compared with robotic (PT: Lap 0.14 versus Robot 0.00 EPT, P = 0.04). Among expert robotic surgeons, greater errors were noted during laparoscopic PC compared with robotic (Lap 0.80 versus Robot 0.13 EPT, P = 0.02). Among expert laparoscopists, task performance was slower on the robotic platform compared with laparoscopy. In comparisons of expert laparoscopists performing tasks on the laparoscopic platform and expert robotic surgeons performing tasks on the robotic platform, expert robotic surgeons demonstrated fewer errors during the PC task (P = 0.009). Robotic assistance provided a reduction in errors at all experience levels for some laparoscopic tasks, but no benefit in the speed of task performance. Robotic assistance may provide some benefit in precision of surgical task performance. Copyright © 2017 Elsevier Inc. All rights reserved.

  11. Virtual surgical planning and 3D printing in repeat calvarial vault reconstruction for craniosynostosis: technical note.

    PubMed

    LoPresti, Melissa; Daniels, Bradley; Buchanan, Edward P; Monson, Laura; Lam, Sandi

    2017-04-01

    Repeat surgery for restenosis after initial nonsyndromic craniosynostosis intervention is sometimes needed. Calvarial vault reconstruction through a healed surgical bed adds a level of intraoperative complexity and may benefit from preoperative and intraoperative definitions of biometric and aesthetic norms. Computer-assisted design and manufacturing using 3D imaging allows the precise formulation of operative plans in anticipation of surgical intervention. 3D printing turns virtual plans into anatomical replicas, templates, or customized implants by using a variety of materials. The authors present a technical note illustrating the use of this technology: a repeat calvarial vault reconstruction that was planned and executed using computer-assisted design and 3D printed intraoperative guides.

  12. Assessment of errors and biases in retrievals of XCO2, XCH4, XCO, and XN2O from a 0.5 cm-1 resolution solar-viewing spectrometer

    NASA Astrophysics Data System (ADS)

    Hedelius, Jacob K.; Viatte, Camille; Wunch, Debra; Roehl, Coleen M.; Toon, Geoffrey C.; Chen, Jia; Jones, Taylor; Wofsy, Steven C.; Franklin, Jonathan E.; Parker, Harrison; Dubey, Manvendra K.; Wennberg, Paul O.

    2016-08-01

    Bruker™ EM27/SUN instruments are commercial mobile solar-viewing near-IR spectrometers. They show promise for expanding the global density of atmospheric column measurements of greenhouse gases and are being marketed for such applications. They have been shown to measure the same variations of atmospheric gases within a day as the high-resolution spectrometers of the Total Carbon Column Observing Network (TCCON). However, there is little known about the long-term precision and uncertainty budgets of EM27/SUN measurements. In this study, which includes a comparison of 186 measurement days spanning 11 months, we note that atmospheric variations of Xgas within a single day are well captured by these low-resolution instruments, but over several months, the measurements drift noticeably. We present comparisons between EM27/SUN instruments and the TCCON using GGG as the retrieval algorithm. In addition, we perform several tests to evaluate the robustness of the performance and determine the largest sources of errors from these spectrometers. We include comparisons of XCO2, XCH4, XCO, and XN2O. Specifically we note EM27/SUN biases for January 2015 of 0.03, 0.75, -0.12, and 2.43 % for XCO2, XCH4, XCO, and XN2O respectively, with 1σ running precisions of 0.08 and 0.06 % for XCO2 and XCH4 from measurements in Pasadena. We also identify significant error caused by nonlinear sensitivity when using an extended spectral range detector used to measure CO and N2O.

  13. Precision Topography of Pluvial Features in Nevada as Analogs for Possible Pluvial Landforms on Mars

    NASA Astrophysics Data System (ADS)

    Zimbelman, J. R.; Garry, W. B.; Irwin, R. P.

    2009-12-01

    Topographic measurements with better than 2 cm horizontal and 4 cm vertical precision were obtained for pluvial features in Nevada using a Trimble R8 Differential Global Positioning System (DGPS), making use of both real-time kinematic and post-processed kinematic techniques. We collected ten transects across shorelines in the southern end of Surprise Valley, near the California border in NW Nevada, on April 15-17, 2008, plus five transects of shorelines and eight transects of a wavecut scarp in Long Valley, near the Utah border in NE Nevada, on May 5-7, 2009. Each transect consists of topographic points keyed to field notes and photographs. In Surprise Valley, the highstand shoreline was noted at 1533.4 m elevation in 8 of the 10 transects, and several prominent intermediate shorelines could be correlated between two or more transects. In Long Valley, the well preserved highstand shoreline elevation of 1908.7 m correlated (within 0.6 m) to the base of the wavecut scarp along a horizontal distance of 1.2 km. These results demonstrate that adherence to a geopotential elevation level is one of the strongest indicators that a possible shoreline feature is the result of pluvial processes, and that elevation levels of features can be clearly detected and documented with precise topographic measurements. The High Resolution Imaging Science Experiment (HiRISE) is returning images of Mars that show potential shoreline features in remarkable detail (e.g., image PSP_009998_2165, 32 cm/pixel, showing a possible shoreline in NW Arabia). Our results from studying shorelines in Nevada will provide a basis for evaluating the plausibility of possible shoreline features on Mars, the implications of which are significant for the overall history of Mars.

  14. A Note on "Accuracy" and "Precision"

    ERIC Educational Resources Information Center

    Stallings, William M.; Gillmore, Gerald M.

    1971-01-01

    Advocates the use of precision" rather than accuracy" in defining reliability. These terms are consistently differentiated in certain sciences. Review of psychological and measurement literature reveals, however, interchangeable usage of the terms in defining reliability. (Author/GS)

  15. Fractal geometry of music.

    PubMed Central

    Hsü, K J; Hsü, A J

    1990-01-01

    Music critics have compared Bach's music to the precision of mathematics. What "mathematics" and what "precision" are the questions for a curious scientist. The purpose of this short note is to suggest that the mathematics is, at least in part, Mandelbrot's fractal geometry and the precision is the deviation from a log-log linear plot. PMID:11607061

  16. Precision pointing of the international ultraviolet explorer /IUE/ scientific instrument using a gyroscopic and stellar reference

    NASA Technical Reports Server (NTRS)

    Moore, J. V.

    1976-01-01

    The Attitude Control System for the IUE spacecraft is described. The basic mission objectives are stated and a sequential discussion of the mission is presented. Desired accuracy for each mission phase is noted and where applicable the onboard control mechanization is shown. Sensors and actuator systems utilized by the control algorithms are described. Finally, onboard software is discussed to a level necessary to understand the prime mission mode operation.

  17. Note: Precise radial distribution of charged particles in a magnetic guiding field

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Backe, H., E-mail: backe@kph.uni-mainz.de

    2015-07-15

    Current high precision beta decay experiments of polarized neutrons, employing magnetic guiding fields in combination with position sensitive and energy dispersive detectors, resulted in a detailed study of the mono-energetic point spread function (PSF) for a homogeneous magnetic field. A PSF describes the radial probability distribution of mono-energetic electrons at the detector plane emitted from a point-like source. With regard to accuracy considerations, unwanted singularities occur as a function of the radial detector coordinate which have recently been investigated by subdividing the radial coordinate into small bins or employing analytical approximations. In this note, a series expansion of the PSFmore » is presented which can numerically be evaluated with arbitrary precision.« less

  18. Note: Directly measuring the direct digital synthesizer frequency chirp-rate for an atom interferometer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tao, Juan-Juan; Zhou, Min-Kang, E-mail: zkhu@hust.edu.cn, E-mail: zmk@hust.edu.cn; Zhang, Qiao-Zhen

    2015-09-15

    During gravity measurements with Raman type atom interferometry, the frequency of the laser used to drive Raman transition is scanned by chirping the frequency of a direct digital synthesizer (DDS), and the local gravity is determined by precisely measuring the chip rate α of DDS. We present an effective method that can directly evaluate the frequency chirp rate stability of our DDS. By mixing a pair of synchronous linear sweeping signals, the chirp rate fluctuation is precisely measured with a frequency counter. The measurement result shows that the relative α instability can reach 5.7 × 10{sup −11} in 1 s,more » which is neglectable in a 10{sup −9} g level atom interferometry gravimeter.« less

  19. Helicopter flight investigation to determine the effects of a closed-circuit TV on performance of a precision sling-load handling task

    NASA Technical Reports Server (NTRS)

    Dicarlo, D. J.; Kelley, H. L.; Spivey, D. L.

    1974-01-01

    Helicopter sling-load operations have been limited during hover and low-speed flight by the degree of precision achieved by the pilot/helicopter/sling-load combination. Previous attempts to improve precision have included stabilization of the load and helicopter and the addition of a pilot station directly facing the load. In these tests, use of a closed-circuit TV as a display that would permit sling-load delivery and placement by the forward-facing pilot was evaluated using a CH-54B helicopter. In all, three test cases were documented, which included the following: (1) forward-facing pilot using the TV display, (2) forward-facing pilot using verbal commands from a load-facing observer, and (3) aft-facing pilot using direct visual cues. The results indicate that a comparable level of performance was achieved for each test case; however, an increase in pilot workload was noted when the TV system was used.

  20. Note: Eddy current displacement sensors independent of target conductivity.

    PubMed

    Wang, Hongbo; Li, Wei; Feng, Zhihua

    2015-01-01

    Eddy current sensors (ECSs) are widely used for non-contact displacement measurement. In this note, the quantitative error of an ECS caused by target conductivity was analyzed using a complex image method. The response curves (L-x) of the ECS with different targets were similar and could be overlapped by shifting the curves on x direction with √2δ/2. Both finite element analysis and experiments match well with the theoretical analysis, which indicates that the measured error of high precision ECSs caused by target conductivity can be completely eliminated, and the ECSs can measure different materials precisely without calibration.

  1. Validating a strategy for psychosocial phenotyping using a large corpus of clinical text.

    PubMed

    Gundlapalli, Adi V; Redd, Andrew; Carter, Marjorie; Divita, Guy; Shen, Shuying; Palmer, Miland; Samore, Matthew H

    2013-12-01

    To develop algorithms to improve efficiency of patient phenotyping using natural language processing (NLP) on text data. Of a large number of note titles available in our database, we sought to determine those with highest yield and precision for psychosocial concepts. From a database of over 1 billion documents from US Department of Veterans Affairs medical facilities, a random sample of 1500 documents from each of 218 enterprise note titles were chosen. Psychosocial concepts were extracted using a UIMA-AS-based NLP pipeline (v3NLP), using a lexicon of relevant concepts with negation and template format annotators. Human reviewers evaluated a subset of documents for false positives and sensitivity. High-yield documents were identified by hit rate and precision. Reasons for false positivity were characterized. A total of 58 707 psychosocial concepts were identified from 316 355 documents for an overall hit rate of 0.2 concepts per document (median 0.1, range 1.6-0). Of 6031 concepts reviewed from a high-yield set of note titles, the overall precision for all concept categories was 80%, with variability among note titles and concept categories. Reasons for false positivity included templating, negation, context, and alternate meaning of words. The sensitivity of the NLP system was noted to be 49% (95% CI 43% to 55%). Phenotyping using NLP need not involve the entire document corpus. Our methods offer a generalizable strategy for scaling NLP pipelines to large free text corpora with complex linguistic annotations in attempts to identify patients of a certain phenotype.

  2. Validating a strategy for psychosocial phenotyping using a large corpus of clinical text

    PubMed Central

    Gundlapalli, Adi V; Redd, Andrew; Carter, Marjorie; Divita, Guy; Shen, Shuying; Palmer, Miland; Samore, Matthew H

    2013-01-01

    Objective To develop algorithms to improve efficiency of patient phenotyping using natural language processing (NLP) on text data. Of a large number of note titles available in our database, we sought to determine those with highest yield and precision for psychosocial concepts. Materials and methods From a database of over 1 billion documents from US Department of Veterans Affairs medical facilities, a random sample of 1500 documents from each of 218 enterprise note titles were chosen. Psychosocial concepts were extracted using a UIMA-AS-based NLP pipeline (v3NLP), using a lexicon of relevant concepts with negation and template format annotators. Human reviewers evaluated a subset of documents for false positives and sensitivity. High-yield documents were identified by hit rate and precision. Reasons for false positivity were characterized. Results A total of 58 707 psychosocial concepts were identified from 316 355 documents for an overall hit rate of 0.2 concepts per document (median 0.1, range 1.6–0). Of 6031 concepts reviewed from a high-yield set of note titles, the overall precision for all concept categories was 80%, with variability among note titles and concept categories. Reasons for false positivity included templating, negation, context, and alternate meaning of words. The sensitivity of the NLP system was noted to be 49% (95% CI 43% to 55%). Conclusions Phenotyping using NLP need not involve the entire document corpus. Our methods offer a generalizable strategy for scaling NLP pipelines to large free text corpora with complex linguistic annotations in attempts to identify patients of a certain phenotype. PMID:24169276

  3. Microbarograph - ESRL Hi-Res Microbarograph, Goldendale - Raw Data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McCaffrey, Katherine

    High-precision barometers (Paroscientific 6000-16B-IS) are combined with Nishiyama-Bedard Quad Disk pressure probes, measuring pressure (mb) at the surface, nominally 2 m above ground level. Data are sampled at 20 Hz for potential studies of turbulence. The sensors' high accuracy makes them useful for determining horizontal pressure gradients and their relation to wind ramp events, as well as the temporal variability of pressure associated with mountain wakes and waves. **Note different ASCII file formats for Goldendale (z04) and Walla Walla (z09) sites.**

  4. Microbarograph - ESRL Hi-Res Microbarograph, Condon - Reviewed Data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McCaffrey, Katherine

    High-precision barometers (Paroscientific 6000-16B-IS) are combined with Nishiyama-Bedard Quad Disk pressure probes, measuring pressure (mb) at the surface, nominally 2 m above ground level. Data are sampled at 20 Hz for potential studies of turbulence. The sensors' high accuracy makes them useful for determining horizontal pressure gradients and their relation to wind ramp events, as well as the temporal variability of pressure associated with mountain wakes and waves. **Note different ASCII file formats for Goldendale (z04) and Walla Walla (z09) sites.**

  5. Microbarograph - ESRL Hi-Res Microbarograph, Troutdale - Raw Data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McCaffrey, Katherine

    High-precision barometers (Paroscientific 6000-16B-IS) are combined with Nishiyama-Bedard Quad Disk pressure probes, measuring pressure (mb) at the surface, nominally 2 m above ground level. Data are sampled at 20 Hz for potential studies of turbulence. The sensors' high accuracy makes them useful for determining horizontal pressure gradients and their relation to wind ramp events, as well as the temporal variability of pressure associated with mountain wakes and waves. **Note different ASCII file formats for Goldendale (z04) and Walla Walla (z09) sites.**

  6. Microbarograph - ESRL Hi-Res Microbarograph, Troutdale - Reviewed Data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McCaffrey, Katherine

    High-precision barometers (Paroscientific 6000-16B-IS) are combined with Nishiyama-Bedard Quad Disk pressure probes, measuring pressure (mb) at the surface, nominally 2 m above ground level. Data are sampled at 20 Hz for potential studies of turbulence. The sensors' high accuracy makes them useful for determining horizontal pressure gradients and their relation to wind ramp events, as well as the temporal variability of pressure associated with mountain wakes and waves. **Note different ASCII file formats for Goldendale (z04) and Walla Walla (z09) sites.**

  7. Microbarograph - ESRL Hi-Res Microbarograph, Condon - Raw Data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McCaffrey, Katherine

    High-precision barometers (Paroscientific 6000-16B-IS) are combined with Nishiyama-Bedard Quad Disk pressure probes, measuring pressure (mb) at the surface, nominally 2 m above ground level. Data are sampled at 20 Hz for potential studies of turbulence. The sensors' high accuracy makes them useful for determining horizontal pressure gradients and their relation to wind ramp events, as well as the temporal variability of pressure associated with mountain wakes and waves. **Note different ASCII file formats for Goldendale (z04) and Walla Walla (z09) sites.**

  8. Microbarograph - ESRL Hi-Res Microbarograph, Wasco Airport - Reviewed Data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McCaffrey, Katherine

    High-precision barometers (Paroscientific 6000-16B-IS) are combined with Nishiyama-Bedard Quad Disk pressure probes, measuring pressure (mb) at the surface, nominally 2 m above ground level. Data are sampled at 20 Hz for potential studies of turbulence. The sensors' high accuracy makes them useful for determining horizontal pressure gradients and their relation to wind ramp events, as well as the temporal variability of pressure associated with mountain wakes and waves. **Note different ASCII file formats for Goldendale (z04) and Walla Walla (z09) sites.**

  9. Microbarograph - ESRL Hi-Res Microbarograph, Walla Walla - Raw Data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McCaffrey, Katherine

    High-precision barometers (Paroscientific 6000-16B-IS) are combined with Nishiyama-Bedard Quad Disk pressure probes, measuring pressure (mb) at the surface, nominally 2 m above ground level. Data are sampled at 20 Hz for potential studies of turbulence. The sensors' high accuracy makes them useful for determining horizontal pressure gradients and their relation to wind ramp events, as well as the temporal variability of pressure associated with mountain wakes and waves. **Note different ASCII file formats for Goldendale (z04) and Walla Walla (z09) sites.**

  10. Microbarograph - ESRL Hi-Res Microbarograph, Goldendale - Reviewed Data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McCaffrey, Katherine

    High-precision barometers (Paroscientific 6000-16B-IS) are combined with Nishiyama-Bedard Quad Disk pressure probes, measuring pressure (mb) at the surface, nominally 2 m above ground level. Data are sampled at 20 Hz for potential studies of turbulence. The sensors' high accuracy makes them useful for determining horizontal pressure gradients and their relation to wind ramp events, as well as the temporal variability of pressure associated with mountain wakes and waves. **Note different ASCII file formats for Goldendale (z04) and Walla Walla (z09) sites.**

  11. Microbarograph - ESRL Hi-Res Microbarograph, Walla Walla - Reviewed Data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McCaffrey, Katherine

    High-precision barometers (Paroscientific 6000-16B-IS) are combined with Nishiyama-Bedard Quad Disk pressure probes, measuring pressure (mb) at the surface, nominally 2 m above ground level. Data are sampled at 20 Hz for potential studies of turbulence. The sensors' high accuracy makes them useful for determining horizontal pressure gradients and their relation to wind ramp events, as well as the temporal variability of pressure associated with mountain wakes and waves. **Note different ASCII file formats for Goldendale (z04) and Walla Walla (z09) sites.**

  12. Microbarograph - ESRL Hi-Res Microbarograph, Wasco Airport - Raw Data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McCaffrey, Katherine

    High-precision barometers (Paroscientific 6000-16B-IS) are combined with Nishiyama-Bedard Quad Disk pressure probes, measuring pressure (mb) at the surface, nominally 2 m above ground level. Data are sampled at 20 Hz for potential studies of turbulence. The sensors' high accuracy makes them useful for determining horizontal pressure gradients and their relation to wind ramp events, as well as the temporal variability of pressure associated with mountain wakes and waves. **Note different ASCII file formats for Goldendale (z04) and Walla Walla (z09) sites.**

  13. Microbarograph - ESRL Hi-Res Microbarograph, Boardman - Raw Data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McCaffrey, Katherine

    High-precision barometers (Paroscientific 6000-16B-IS) are combined with Nishiyama-Bedard Quad Disk pressure probes, measuring pressure (mb) at the surface, nominally 2 m above ground level. Data are sampled at 20 Hz for potential studies of turbulence. The sensors' high accuracy makes them useful for determining horizontal pressure gradients and their relation to wind ramp events, as well as the temporal variability of pressure associated with mountain wakes and waves. **Note different ASCII file formats for Goldendale (z04) and Walla Walla (z09) sites.**

  14. Microbarograph - ESRL Hi-Res Microbarograph, John Day - Raw Data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McCaffrey, Katherine

    High-precision barometers (Paroscientific 6000-16B-IS) are combined with Nishiyama-Bedard Quad Disk pressure probes, measuring pressure (mb) at the surface, nominally 2 m above ground level. Data are sampled at 20 Hz for potential studies of turbulence. The sensors' high accuracy makes them useful for determining horizontal pressure gradients and their relation to wind ramp events, as well as the temporal variability of pressure associated with mountain wakes and waves. **Note different ASCII file formats for Goldendale (z04) and Walla Walla (z09) sites.**

  15. Microbarograph - ESRL Hi-Res Microbarograph, Hood River - Raw Data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McCaffrey, Katherine

    High-precision barometers (Paroscientific 6000-16B-IS) are combined with Nishiyama-Bedard Quad Disk pressure probes, measuring pressure (mb) at the surface, nominally 2 m above ground level. Data are sampled at 20 Hz for potential studies of turbulence. The sensors' high accuracy makes them useful for determining horizontal pressure gradients and their relation to wind ramp events, as well as the temporal variability of pressure associated with mountain wakes and waves. **Note different ASCII file formats for Goldendale (z04) and Walla Walla (z09) sites.**

  16. Microbarograph - ESRL Hi-Res Microbarograph, Umatilla - Reviewed Data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McCaffrey, Katherine

    High-precision barometers (Paroscientific 6000-16B-IS) are combined with Nishiyama-Bedard Quad Disk pressure probes, measuring pressure (mb) at the surface, nominally 2 m above ground level. Data are sampled at 20 Hz for potential studies of turbulence. The sensors' high accuracy makes them useful for determining horizontal pressure gradients and their relation to wind ramp events, as well as the temporal variability of pressure associated with mountain wakes and waves. **Note different ASCII file formats for Goldendale (z04) and Walla Walla (z09) sites.**

  17. Microbarograph - ESRL Hi-Res Microbarograph, Boardman - Reviewed Data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McCaffrey, Katherine

    High-precision barometers (Paroscientific 6000-16B-IS) are combined with Nishiyama-Bedard Quad Disk pressure probes, measuring pressure (mb) at the surface, nominally 2 m above ground level. Data are sampled at 20 Hz for potential studies of turbulence. The sensors' high accuracy makes them useful for determining horizontal pressure gradients and their relation to wind ramp events, as well as the temporal variability of pressure associated with mountain wakes and waves. **Note different ASCII file formats for Goldendale (z04) and Walla Walla (z09) sites.**

  18. Microbarograph - ESRL Hi-Res Microbarograph, Bonneville - Reviewed Data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McCaffrey, Katherine

    High-precision barometers (Paroscientific 6000-16B-IS) are combined with Nishiyama-Bedard Quad Disk pressure probes, measuring pressure (mb) at the surface, nominally 2 m above ground level. Data are sampled at 20 Hz for potential studies of turbulence. The sensors' high accuracy makes them useful for determining horizontal pressure gradients and their relation to wind ramp events, as well as the temporal variability of pressure associated with mountain wakes and waves. **Note different ASCII file formats for Goldendale (z04) and Walla Walla (z09) sites.**

  19. Microbarograph - ESRL Hi-Res Microbarograph, Bonneville - Raw Data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McCaffrey, Katherine

    High-precision barometers (Paroscientific 6000-16B-IS) are combined with Nishiyama-Bedard Quad Disk pressure probes, measuring pressure (mb) at the surface, nominally 2 m above ground level. Data are sampled at 20 Hz for potential studies of turbulence. The sensors' high accuracy makes them useful for determining horizontal pressure gradients and their relation to wind ramp events, as well as the temporal variability of pressure associated with mountain wakes and waves. **Note different ASCII file formats for Goldendale (z04) and Walla Walla (z09) sites.**

  20. Microbarograph - ESRL Hi-Res Microbarograph, Umatilla - Raw Data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McCaffrey, Katherine

    High-precision barometers (Paroscientific 6000-16B-IS) are combined with Nishiyama-Bedard Quad Disk pressure probes, measuring pressure (mb) at the surface, nominally 2 m above ground level. Data are sampled at 20 Hz for potential studies of turbulence. The sensors' high accuracy makes them useful for determining horizontal pressure gradients and their relation to wind ramp events, as well as the temporal variability of pressure associated with mountain wakes and waves. **Note different ASCII file formats for Goldendale (z04) and Walla Walla (z09) sites.**

  1. Microbarograph - ESRL Hi-Res Microbarograph, John Day - Reviewed Data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McCaffrey, Katherine

    High-precision barometers (Paroscientific 6000-16B-IS) are combined with Nishiyama-Bedard Quad Disk pressure probes, measuring pressure (mb) at the surface, nominally 2 m above ground level. Data are sampled at 20 Hz for potential studies of turbulence. The sensors' high accuracy makes them useful for determining horizontal pressure gradients and their relation to wind ramp events, as well as the temporal variability of pressure associated with mountain wakes and waves. **Note different ASCII file formats for Goldendale (z04) and Walla Walla (z09) sites.**

  2. Microbarograph - ESRL Hi-Res Microbarograph, Hood River - Reviewed Data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McCaffrey, Katherine

    High-precision barometers (Paroscientific 6000-16B-IS) are combined with Nishiyama-Bedard Quad Disk pressure probes, measuring pressure (mb) at the surface, nominally 2 m above ground level. Data are sampled at 20 Hz for potential studies of turbulence. The sensors' high accuracy makes them useful for determining horizontal pressure gradients and their relation to wind ramp events, as well as the temporal variability of pressure associated with mountain wakes and waves. **Note different ASCII file formats for Goldendale (z04) and Walla Walla (z09) sites.**

  3. 40 CFR 1065.1103 - General provisions for SVOC measurement.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    .... Note that the precise method you use will depend on the category of SVOCs being measured. For example... and should periodically accompany the test sampling system throughout the course of a test, including... be a natural byproduct of combustion or they may be created post-combustion. Note that SVOCs may be...

  4. Topic categorisation of statements in suicide notes with integrated rules and machine learning.

    PubMed

    Kovačević, Aleksandar; Dehghan, Azad; Keane, John A; Nenadic, Goran

    2012-01-01

    We describe and evaluate an automated approach used as part of the i2b2 2011 challenge to identify and categorise statements in suicide notes into one of 15 topics, including Love, Guilt, Thankfulness, Hopelessness and Instructions. The approach combines a set of lexico-syntactic rules with a set of models derived by machine learning from a training dataset. The machine learning models rely on named entities, lexical, lexico-semantic and presentation features, as well as the rules that are applicable to a given statement. On a testing set of 300 suicide notes, the approach showed the overall best micro F-measure of up to 53.36%. The best precision achieved was 67.17% when only rules are used, whereas best recall of 50.57% was with integrated rules and machine learning. While some topics (eg, Sorrow, Anger, Blame) prove challenging, the performance for relatively frequent (eg, Love) and well-scoped categories (eg, Thankfulness) was comparatively higher (precision between 68% and 79%), suggesting that automated text mining approaches can be effective in topic categorisation of suicide notes.

  5. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gasparian, Ashot

    Properties of the neutral pion, as the lightest hadron in Nature, are most sensitive to the basic symmetries and their partial breaking effects in the theory of the strong interaction (QCD). In particular, the po →gg decay width is primarily defined by the spontaneous chiral symmetry breaking effect (chiral anomaly) in QCD. The next order corrections to the anomaly have been shown to be small and are known to a 1% precision level. The PrimEx Collaboration at JLab has developed and performed two Primakoff type experiments to measure the po →gg decay width with a similar precision. The published resultmore » from the PrimEx-I experiment, G(p0 →gg ) = 7.82±0.14 (stat.)±0.17 (syst.) eV, was a factor of two more precise than the average value quoted in PDG-2010 [1]. The second experiment was performed in 2010 with a goal of 1.4% total uncertainty to address the next-to-leading-order theory calculations. The preliminary results from the PrimEx-II experiment are presented and discussed in this note.« less

  6. Note: Improved calibration of atomic force microscope cantilevers using multiple reference cantilevers.

    PubMed

    Sader, John E; Friend, James R

    2015-05-01

    Overall precision of the simplified calibration method in J. E. Sader et al., Rev. Sci. Instrum. 83, 103705 (2012), Sec. III D, is dominated by the spring constant of the reference cantilever. The question arises: How does one take measurements from multiple reference cantilevers, and combine these results, to improve uncertainty of the reference cantilever's spring constant and hence the overall precision of the method? This question is addressed in this note. Its answer enables manufacturers to specify of a single set of data for the spring constant, resonant frequency, and quality factor, from measurements on multiple reference cantilevers. With this data set, users can trivially calibrate cantilevers of the same type.

  7. Text Mining for Precision Medicine: Bringing structure to EHRs and biomedical literature to understand genes and health

    PubMed Central

    Simmons, Michael; Singhal, Ayush; Lu, Zhiyong

    2018-01-01

    The key question of precision medicine is whether it is possible to find clinically actionable granularity in diagnosing disease and classifying patient risk. The advent of next generation sequencing and the widespread adoption of electronic health records (EHRs) have provided clinicians and researchers a wealth of data and made possible the precise characterization of individual patient genotypes and phenotypes. Unstructured text — found in biomedical publications and clinical notes — is an important component of genotype and phenotype knowledge. Publications in the biomedical literature provide essential information for interpreting genetic data. Likewise, clinical notes contain the richest source of phenotype information in EHRs. Text mining can render these texts computationally accessible and support information extraction and hypothesis generation. This chapter reviews the mechanics of text mining in precision medicine and discusses several specific use cases, including database curation for personalized cancer medicine, patient outcome prediction from EHR-derived cohorts, and pharmacogenomic research. Taken as a whole, these use cases demonstrate how text mining enables effective utilization of existing knowledge sources and thus promotes increased value for patients and healthcare systems. Text mining is an indispensable tool for translating genotype-phenotype data into effective clinical care that will undoubtedly play an important role in the eventual realization of precision medicine. PMID:27807747

  8. Text Mining for Precision Medicine: Bringing Structure to EHRs and Biomedical Literature to Understand Genes and Health.

    PubMed

    Simmons, Michael; Singhal, Ayush; Lu, Zhiyong

    2016-01-01

    The key question of precision medicine is whether it is possible to find clinically actionable granularity in diagnosing disease and classifying patient risk. The advent of next-generation sequencing and the widespread adoption of electronic health records (EHRs) have provided clinicians and researchers a wealth of data and made possible the precise characterization of individual patient genotypes and phenotypes. Unstructured text-found in biomedical publications and clinical notes-is an important component of genotype and phenotype knowledge. Publications in the biomedical literature provide essential information for interpreting genetic data. Likewise, clinical notes contain the richest source of phenotype information in EHRs. Text mining can render these texts computationally accessible and support information extraction and hypothesis generation. This chapter reviews the mechanics of text mining in precision medicine and discusses several specific use cases, including database curation for personalized cancer medicine, patient outcome prediction from EHR-derived cohorts, and pharmacogenomic research. Taken as a whole, these use cases demonstrate how text mining enables effective utilization of existing knowledge sources and thus promotes increased value for patients and healthcare systems. Text mining is an indispensable tool for translating genotype-phenotype data into effective clinical care that will undoubtedly play an important role in the eventual realization of precision medicine.

  9. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Møller, Jacob Schach

    These notes provide an introduction to the spectral analysis of Pauli-Fierz systems at zero and positive temperature. More precisely, we study finite dimensional quantum systems linearly coupled to a single reservoir, a massless scalar quantum field. We emphasize structure results valid at arbitrary system-reservoir coupling strength. The notes contain a mixture of known, refined, and new results and each section ends with a discussion of open problems.

  10. Clinical translation of photobiomodulation therapy using evidences from precision molecular pathway analyses (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Arany, Praveen

    2017-02-01

    Can `light' be a Drug? To satisfy this definition as a pharmaceutical agent, light must be absorbed and change bodily function. Much evidence from our understanding of our visual cycle and Vitamin D metabolism have all noted this phenomenon. Advances in optophotonic technologies along with a better understanding of light-tissue interactions, especially in in vivo optical imaging and optogenetics, are spearheading the popularity of biophotonics in biology and medicine. The use of lasers and light devices at high doses in dermatology, ophthalmology, oncology and dentistry are now considered mainstream for certain clinical applications such as surgery, skin rejuvenation, ocular and soft tissue recontouring, anti-tumor and anti-microbial photodynamic therapy. In contrast, therapeutic use of low dose biophotonics devices is called Low Level Light / Laser Therapy (LLLT), now termed Photobiomodulation (PBM) Therapy. This therapy is defined as a non-thermal use of non-ionizing forms of electromagnetic radiation to alleviate pain, inflammation, modulating the immune responses and promoting wound healing and tissue regeneration. Surprisingly, despite vast volumes of scientific literature from both clinical and laboratory studies noting the phenomenological evidences for this innovative therapy, limited mechanistic insights have prevented the development of rigorous, reproducible clinical protocols. This presentation will outline our current efforts at ongoing efforts in our group to assess molecular pathways and precisely define clinical treatment variables to enable clinical translation with PBM therapies.

  11. Note: Improved calibration of atomic force microscope cantilevers using multiple reference cantilevers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sader, John E., E-mail: jsader@unimelb.edu.au; Friend, James R.

    2015-05-15

    Overall precision of the simplified calibration method in J. E. Sader et al., Rev. Sci. Instrum. 83, 103705 (2012), Sec. III D, is dominated by the spring constant of the reference cantilever. The question arises: How does one take measurements from multiple reference cantilevers, and combine these results, to improve uncertainty of the reference cantilever’s spring constant and hence the overall precision of the method? This question is addressed in this note. Its answer enables manufacturers to specify of a single set of data for the spring constant, resonant frequency, and quality factor, from measurements on multiple reference cantilevers. Withmore » this data set, users can trivially calibrate cantilevers of the same type.« less

  12. Assessing the difficulty and time cost of de-identification in clinical narratives.

    PubMed

    Dorr, D A; Phillips, W F; Phansalkar, S; Sims, S A; Hurdle, J F

    2006-01-01

    To characterize the difficulty confronting investigators in removing protected health information (PHI) from cross-discipline, free-text clinical notes, an important challenge to clinical informatics research as recalibrated by the introduction of the US Health Insurance Portability and Accountability Act (HIPAA) and similar regulations. Randomized selection of clinical narratives from complete admissions written by diverse providers, reviewed using a two-tiered rater system and simple automated regular expression tools. For manual review, two independent reviewers used simple search and replace algorithms and visual scanning to find PHI as defined by HIPAA, followed by an independent second review to detect any missed PHI. Simple automated review was also performed for the "easy" PHI that are number- or date-based. From 262 notes, 2074 PHI, or 7.9 +/- 6.1 per note, were found. The average recall (or sensitivity) was 95.9% while precision was 99.6% for single reviewers. Agreement between individual reviewers was strong (ICC = 0.99), although some asymmetry in errors was seen between reviewers (p = 0.001). The automated technique had better recall (98.5%) but worse precision (88.4%) for its subset of identifiers. Manually de-identifying a note took 87.3 +/- 61 seconds on average. Manual de-identification of free-text notes is tedious and time-consuming, but even simple PHI is difficult to automatically identify with the exactitude required under HIPAA.

  13. Analysis of Tonguing and Blowing Actions During Clarinet Performance.

    PubMed

    Pàmies-Vilà, Montserrat; Hofmann, Alex; Chatziioannou, Vasileios

    2018-01-01

    Articulation on the clarinet is achieved by a combination of precise actions taking place inside the player's mouth. With the aim to analyse the effects of tonguing and blowing actions during playing, several physical variables are measured and parameters related to articulation are studied. Mouth pressure, mouthpiece pressure and reed displacement are recorded in an experiment with clarinet players to evaluate the influence of the player's actions on the selected parameters and on the sound. The results show that different combinations of tongue and blowing actions are used during performance. Portato and legato playing show constant blowing throughout the musical phrase, which varies according to the dynamic level. In portato, short tongue-reed interaction is used homogeneously among players and playing conditions. In staccato playing, where the tongue-reed contact is longer, the mouth pressure is reduced significantly between notes. Such a mouth-pressure decrease might be used to stop the note in slow staccato playing. It is hereby shown that when the note is stopped by the action of the tongue both the attack and release transients are shorter compared to the case where the vibration of the reed is stopped by a decrease of mouth pressure.

  14. Information theory analysis of patterns of modulation in the advertisement call of the male bullfrog, Rana catesbeianaa)

    PubMed Central

    Suggs, Dianne N.; Simmons, Andrea Megela

    2005-01-01

    Male bullfrogs often amplitude modulate the envelopes of the individual notes (croaks) in their multinote advertisement calls. These amplitude modulations change the envelope of the note from smooth and unmodulated to one with varying numbers of modulations. A Markov analysis shows the pattern of change in the envelope to be highly ordered, but not completely so (semi-Markovian). Three simple rules govern the presence or absence of modulations in individual notes. These rules are (1) all calls begin with an unmodulated note; (2) the first note to be modulated will contain only one modulation; and (3) when a change in modulation occurs from one note to the next, it does so with an increase or a decrease of one modulation only. The addition of modulations is correlated with an increase in note duration. Physiologically, the presence of modulations might increase the precision of temporal coding of note periodicities in the central auditory system. PMID:15898673

  15. Note: An absolute X-Y-Θ position sensor using a two-dimensional phase-encoded binary scale

    NASA Astrophysics Data System (ADS)

    Kim, Jong-Ahn; Kim, Jae Wan; Kang, Chu-Shik; Jin, Jonghan

    2018-04-01

    This Note presents a new absolute X-Y-Θ position sensor for measuring planar motion of a precision multi-axis stage system. By analyzing the rotated image of a two-dimensional phase-encoded binary scale (2D), the absolute 2D position values at two separated points were obtained and the absolute X-Y-Θ position could be calculated combining these values. The sensor head was constructed using a board-level camera, a light-emitting diode light source, an imaging lens, and a cube beam-splitter. To obtain the uniform intensity profiles from the vignette scale image, we selected the averaging directions deliberately, and higher resolution in the angle measurement could be achieved by increasing the allowable offset size. The performance of a prototype sensor was evaluated in respect of resolution, nonlinearity, and repeatability. The sensor could resolve 25 nm linear and 0.001° angular displacements clearly, and the standard deviations were less than 18 nm when 2D grid positions were measured repeatedly.

  16. Notes on the uwainat oil rim development, Maydan Mahzam and Bul Hanine Fields, offshore Qatar

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hamam, K.A.

    As a result of reservoir simulation studies of the Uwainat reservoirs (Maydan Mahzam and Bul Hanine Fields), drilling to the Uwainat oil rim target became very ''tight'' with a very limited vertical tolerance. To achieve drilling to the tight target requires a precise position of the well at the top of the Lower Arab IV reservoir (a reliable marker) and an accurate isochore of the Lower Arab IV - Uwainat. The discussion shows that the level of accuracy needed in determining both the actual subsea well position and in constructing the depth contours of the reservoirs is extremely high.

  17. Code-Phase Clock Bias and Frequency Offset in PPP Clock Solutions.

    PubMed

    Defraigne, Pascale; Sleewaegen, Jean-Marie

    2016-07-01

    Precise point positioning (PPP) is a zero-difference single-station technique that has proved to be very effective for time and frequency transfer, enabling the comparison of atomic clocks with a precision of a hundred picoseconds and a one-day stability below the 1e-15 level. It was, however, noted that for some receivers, a frequency difference is observed between the clock solution based on the code measurements and the clock solution based on the carrier-phase measurements. These observations reveal some inconsistency either between the code and carrier phases measured by the receiver or between the data analysis strategy of codes and carrier phases. One explanation for this discrepancy is the time offset that can exist for some receivers between the code and the carrier-phase latching. This paper explains how a code-phase bias in the receiver hardware can induce a frequency difference between the code and the carrier-phase clock solutions. The impact on PPP is then quantified. Finally, the possibility to determine this code-phase bias in the PPP modeling is investigated, and the first results are shown to be inappropriate due to the high level of code noise.

  18. A Low-Cost Precision Colorimeter.

    ERIC Educational Resources Information Center

    Jaffar, M.; Zahid, Qazi

    1988-01-01

    Presents the construction aspects of a simple but reliable colorimeter made from locally available components. Notes the absorption range to be 400-750-nm. Lists seven experiments done on the instrument. (MVL)

  19. Technical Note: The determination of enclosed water volume in large flexible-wall mesocosms "KOSMOS"

    NASA Astrophysics Data System (ADS)

    Czerny, J.; Schulz, K. G.; Krug, S. A.; Ludwig, A.; Riebesell, U.

    2013-03-01

    The volume of water enclosed inside flexible-wall mesocosm bags is hard to estimate using geometrical calculations and can be strongly variable among bags of the same dimensions. Here we present a method for precise water volume determination in mesocosms using salinity as a tracer. Knowledge of the precise volume of water enclosed allows establishment of exactly planned treatment concentrations and calculation of elemental budgets.

  20. “MODAL NOISE” IN SINGLE-MODE FIBERS: A CAUTIONARY NOTE FOR HIGH PRECISION RADIAL VELOCITY INSTRUMENTS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Halverson, Samuel; Roy, Arpita; Mahadevan, Suvrath

    2015-12-01

    Exploring the use of single-mode fibers (SMFs) in high precision Doppler spectrometers has become increasingly attractive since the advent of diffraction-limited adaptive optics systems on large-aperture telescopes. Spectrometers fed with these fibers can be made significantly smaller than typical “seeing-limited” instruments, greatly reducing cost and overall complexity. Importantly, classical mode interference and speckle issues associated with multi-mode fibers, also known as “modal noise,” are mitigated when using SMFs, which also provide perfect radial and azimuthal image scrambling. However, SMFs do support multiple polarization modes, an issue that is generally ignored for larger-core fibers given the large number of propagation modes.more » Since diffraction gratings used in most high resolution astronomical instruments have dispersive properties that are sensitive to incident polarization changes, any birefringence variations in the fiber can cause variations in the efficiency profile, degrading illumination stability. Here we present a cautionary note outlining how the polarization properties of SMFs can affect the radial velocity (RV) measurement precision of high resolution spectrographs. This work is immediately relevant to the rapidly expanding field of diffraction-limited, extreme precision RV spectrographs that are currently being designed and built by a number of groups.« less

  1. DESIGN NOTE: New apparatus for haze measurement for transparent media

    NASA Astrophysics Data System (ADS)

    Yu, H. L.; Hsiao, C. C.; Liu, W. C.

    2006-08-01

    Precise measurement of luminous transmittance and haze of transparent media is increasingly important to the LCD industry. Currently there are at least three documentary standards for measuring transmission haze. Unfortunately, none of those standard methods by itself can obtain the precise values for the diffuse transmittance (DT), total transmittance (TT) and haze. This note presents a new apparatus capable of precisely measuring all three variables simultaneously. Compared with current structures, the proposed design contains one more compensatory port. For optimal design, the light trap absorbs the beam completely, light scattered by the instrument is zero and the interior surface of the integrating sphere, baffle, as well as the reflectance standard, are of equal characteristic. The accurate values of the TT, DT and haze can be obtained using the new apparatus. Even if the design is not optimal, the measurement errors of the new apparatus are smaller than those of other methods especially for high sphere reflectance. Therefore, the sphere can be made of a high reflectance material for the new apparatus to increase the signal-to-noise ratio.

  2. Extracting important information from Chinese Operation Notes with natural language processing methods.

    PubMed

    Wang, Hui; Zhang, Weide; Zeng, Qiang; Li, Zuofeng; Feng, Kaiyan; Liu, Lei

    2014-04-01

    Extracting information from unstructured clinical narratives is valuable for many clinical applications. Although natural Language Processing (NLP) methods have been profoundly studied in electronic medical records (EMR), few studies have explored NLP in extracting information from Chinese clinical narratives. In this study, we report the development and evaluation of extracting tumor-related information from operation notes of hepatic carcinomas which were written in Chinese. Using 86 operation notes manually annotated by physicians as the training set, we explored both rule-based and supervised machine-learning approaches. Evaluating on unseen 29 operation notes, our best approach yielded 69.6% in precision, 58.3% in recall and 63.5% F-score. Copyright © 2014 Elsevier Inc. All rights reserved.

  3. Different responses in soleus muscle fibers of Wistar and Wistar Hannover rats to hindlimb unloading

    NASA Astrophysics Data System (ADS)

    Wang, Xiaodong; Kawano, Fuminori; Terada, Masahiro; Matsuoka, Yoshikazu; Shinoda, Yo; Ishihara, Akihiko; Ohira, Yoshinobu

    2005-08-01

    Effects of 16 days of hindlimb suspension on the characteristics of single soleus muscle fibers were compared between male Wistar and Wistar Hannover rats (5 weeks old). The greater effects of unloading were noted in Wistar Hannover rats. The unloading-related reductions of muscle weight and fiber cross-sectional area vs. the pre-suspension levels were greater than Wistar rats. The percent of fibers expressing pure type I myosin heavy chain (MHC) was decreased and that of type I+II MHC fibers was increased, the magnitudes of these changes were greater than Wistar rats. Total number of myonuclei in control situation was greater in Wistar Hannover rats, but the more numbers of myonuclei were decreased following unloading. Responses of myonuclear domain levels were similar. The numbers of both quiescent and mitotic active satellite cells in control situation were greater in Wistar rats. But the magnitude of the unloading- related decrease was identical for Wistar Hannover and Wistar rats. Although the level of heat shock protein 27 (HSP27) expression in Wistar rats was decreased by unloading, de novo appearance of HSP27 was noted in Wistar Hannover rats. It is suggested that greater responses of soleus muscle fibers of Wistar Hannover than Wistar rats may be related to the different expression of protein, although the precise mechanism is still unclear.

  4. Multivariate Statistics Applied to Seismic Phase Picking

    NASA Astrophysics Data System (ADS)

    Velasco, A. A.; Zeiler, C. P.; Anderson, D.; Pingitore, N. E.

    2008-12-01

    The initial effort of the Seismogram Picking Error from Analyst Review (SPEAR) project has been to establish a common set of seismograms to be picked by the seismological community. Currently we have 13 analysts from 4 institutions that have provided picks on the set of 26 seismograms. In comparing the picks thus far, we have identified consistent biases between picks from different institutions; effects of the experience of analysts; and the impact of signal-to-noise on picks. The institutional bias in picks brings up the important concern that picks will not be the same between different catalogs. This difference means less precision and accuracy when combing picks from multiple institutions. We also note that depending on the experience level of the analyst making picks for a catalog the error could fluctuate dramatically. However, the experience level is based off of number of years in picking seismograms and this may not be an appropriate criterion for determining an analyst's precision. The common data set of seismograms provides a means to test an analyst's level of precision and biases. The analyst is also limited by the quality of the signal and we show that the signal-to-noise ratio and pick error are correlated to the location, size and distance of the event. This makes the standard estimate of picking error based on SNR more complex because additional constraints are needed to accurately constrain the measurement error. We propose to extend the current measurement of error by adding the additional constraints of institutional bias and event characteristics to the standard SNR measurement. We use multivariate statistics to model the data and provide constraints to accurately assess earthquake location and measurement errors.

  5. Interval singing links to phenotypic quality in a songbird

    PubMed Central

    2016-01-01

    Darwin was fascinated by melodic performances of insects, fish, birds, mammals, and men. He considered the ability to produce musical notes without direct use the most mysterious endowment of mankind. Bird song is attributed to sexual selection, but it remains unknown how the expected relationship between melodic performance and phenotypic quality arises. Melodies consist of sequences of notes, and both Pythagoras and music theorists in the Middle Ages found that their tonal frequencies form simple ratios that correspond to small-integer proportions derived from the harmonic series. Harmonics are acoustically predictable, and thus form the basis of the natural, just tuning system in music. Here I analyze the songs of the great tit (Parus major), a bird with a stereotyped song of typically two notes, and test the prediction that the deviations of the intervals from small-integer frequency ratios based on the harmonic series are related to the quality of the singer. I show that the birds with the smallest deviations from small-integer ratios possess the largest melanin-based black ventral tie, a signal that has been demonstrated to indicate social status and dominance, past exposure to parasites, and reproductive potential. The singing of notes with exact frequency relationships requires high levels of motor control and auditory sensory feedback. The finding provides a missing link between melodic precision and phenotypic quality of individuals, which is key for understanding the evolution of vocal melodic expression in animals, and elucidates pathways for the evolution of melodic expression in music. PMID:27791124

  6. Diagnostics of and Specific Hyposensitization to Pollen Rhinopathy (Hay Fever),

    DTIC Science & Technology

    Patients (120 in all) were studied for precise diagnosis of pollen rhinopathy. Among them aggravated allergic heredity was revealed in 63% of cases; a positive allergological anamnesis was noted in 55% of cases.

  7. European Science Notes Information Bulletin Reports on Current European/ Middle Eastern Science

    DTIC Science & Technology

    1991-03-01

    energies and furniture-rotating machinery, and marine. A list of the power density which can be precisely controlled . In European research centers in...43 ESNIB 91-02 By controlling the growth of layers of Si and Si/Ge be the domain of the II-V semiconductors, ar- niwbeing alloys, many research ...Office of Naval Research European Office 91-02 AD-A233 618 ESN INFORMATION BULLETIN European Science Notes Information Bulletin Reports on Current

  8. A short biography of Hubert Ludwig and a note on the publication dates of his monograph Die Seewalzen (1889-1892).

    PubMed

    Reich, Mike

    2015-12-03

    The dates of publication of Hubert Ludwig's (1852-1913) comprehensive monograph Die Seewalzen [= Sea cucumbers] are reviewed. The precise publication dates of his volume, originally published in 16 fascicles and 8 parts/issues, delivered between 1889 and 1892, has been re-examined. Additionally, a short biographical note on Hubert Ludwig's life and a discussion of all new taxa introduced by him in his monograph is given.

  9. Using language models to identify relevant new information in inpatient clinical notes.

    PubMed

    Zhang, Rui; Pakhomov, Serguei V; Lee, Janet T; Melton, Genevieve B

    2014-01-01

    Redundant information in clinical notes within electronic health record (EHR) systems is ubiquitous and may negatively impact the use of these notes by clinicians, and, potentially, the efficiency of patient care delivery. Automated methods to identify redundant versus relevant new information may provide a valuable tool for clinicians to better synthesize patient information and navigate to clinically important details. In this study, we investigated the use of language models for identification of new information in inpatient notes, and evaluated our methods using expert-derived reference standards. The best method achieved precision of 0.743, recall of 0.832 and F1-measure of 0.784. The average proportion of redundant information was similar between inpatient and outpatient progress notes (76.6% (SD=17.3%) and 76.7% (SD=14.0%), respectively). Advanced practice providers tended to have higher rates of redundancy in their notes compared to physicians. Future investigation includes the addition of semantic components and visualization of new information.

  10. Using Language Models to Identify Relevant New Information in Inpatient Clinical Notes

    PubMed Central

    Zhang, Rui; Pakhomov, Serguei V.; Lee, Janet T.; Melton, Genevieve B.

    2014-01-01

    Redundant information in clinical notes within electronic health record (EHR) systems is ubiquitous and may negatively impact the use of these notes by clinicians, and, potentially, the efficiency of patient care delivery. Automated methods to identify redundant versus relevant new information may provide a valuable tool for clinicians to better synthesize patient information and navigate to clinically important details. In this study, we investigated the use of language models for identification of new information in inpatient notes, and evaluated our methods using expert-derived reference standards. The best method achieved precision of 0.743, recall of 0.832 and F1-measure of 0.784. The average proportion of redundant information was similar between inpatient and outpatient progress notes (76.6% (SD=17.3%) and 76.7% (SD=14.0%), respectively). Advanced practice providers tended to have higher rates of redundancy in their notes compared to physicians. Future investigation includes the addition of semantic components and visualization of new information. PMID:25954438

  11. Item response theory and the measurement of motor behavior.

    PubMed

    Safrit, M J; Cohen, A S; Costa, M G

    1989-12-01

    Item response theory (IRT) has been the focus of intense research and development activity in educational and psychological measurement during the past decade. Because this theory can provide more precise information about test items than other theories usually used in measuring motor behavior, the application of IRT in physical education and exercise science merits investigation. In IRT, the difficulty level of each item (e.g., trial or task) can be estimated and placed on the same scale as the ability of the examinee. Using this information, the test developer can determine the ability levels at which the test functions best. Equating the scores of individuals on two or more items or tests can be handled efficiently by applying IRT. The precision of the identification of performance standards in a mastery test context can be enhanced, as can adaptive testing procedures. In this tutorial, several potential benefits of applying IRT to the measurement of motor behavior were described. An example is provided using bowling data and applying the graded-response form of the Rasch IRT model. The data were calibrated and the goodness of fit was examined. This analysis is described in a step-by-step approach. Limitations to using an IRT model with a test consisting of repeated measures were noted.

  12. Note: Space qualified photon counting detector for laser time transfer with picosecond precision and stability

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Prochazka, Ivan, E-mail: prochiva@gmail.com; Blazej, Josef; Kodet, Jan

    2016-05-15

    The laser time transfer link is under construction for the European Space Agency in the frame of Atomic Clock Ensemble in Space. We have developed and tested the flying unit of the photon counting detector optimized for this space mission. The results are summarized in this Note. An extreme challenge was to build a detector package, which is rugged, small and which provides long term detection delay stability on picosecond level. The device passed successfully all the tests required for space missions on the low Earth orbits. The detector is extremely rugged and compact. Its long term detection delay stabilitymore » is excellent, it is better than ±1 ps/day, in a sense of time deviation it is better than 0.5 ps for averaging times of 2000 s to several hours. The device is capable to operate in a temperature range of −55 °C up to +60 °C, the change of the detection delay with temperature is +0.5 ps/K. The device is ready for integration into the space structure now.« less

  13. Note: Space qualified photon counting detector for laser time transfer with picosecond precision and stability.

    PubMed

    Prochazka, Ivan; Kodet, Jan; Blazej, Josef

    2016-05-01

    The laser time transfer link is under construction for the European Space Agency in the frame of Atomic Clock Ensemble in Space. We have developed and tested the flying unit of the photon counting detector optimized for this space mission. The results are summarized in this Note. An extreme challenge was to build a detector package, which is rugged, small and which provides long term detection delay stability on picosecond level. The device passed successfully all the tests required for space missions on the low Earth orbits. The detector is extremely rugged and compact. Its long term detection delay stability is excellent, it is better than ±1 ps/day, in a sense of time deviation it is better than 0.5 ps for averaging times of 2000 s to several hours. The device is capable to operate in a temperature range of -55 °C up to +60 °C, the change of the detection delay with temperature is +0.5 ps/K. The device is ready for integration into the space structure now.

  14. Component Analysis of Errors on PERSIANN Precipitation Estimates over Urmia Lake Basin, IRAN

    NASA Astrophysics Data System (ADS)

    Ghajarnia, N.; Daneshkar Arasteh, P.; Liaghat, A. M.; Araghinejad, S.

    2016-12-01

    In this study, PERSIANN daily dataset is evaluated from 2000 to 2011 in 69 pixels over Urmia Lake basin in northwest of Iran. Different analytical approaches and indexes are used to examine PERSIANN precision in detection and estimation of rainfall rate. The residuals are decomposed into Hit, Miss and FA estimation biases while continues decomposition of systematic and random error components are also analyzed seasonally and categorically. New interpretation of estimation accuracy named "reliability on PERSIANN estimations" is introduced while the changing manners of existing categorical/statistical measures and error components are also seasonally analyzed over different rainfall rate categories. This study yields new insights into the nature of PERSIANN errors over Urmia lake basin as a semi-arid region in the middle-east, including the followings: - The analyzed contingency table indexes indicate better detection precision during spring and fall. - A relatively constant level of error is generally observed among different categories. The range of precipitation estimates at different rainfall rate categories is nearly invariant as a sign for the existence of systematic error. - Low level of reliability is observed on PERSIANN estimations at different categories which are mostly associated with high level of FA error. However, it is observed that as the rate of precipitation increase, the ability and precision of PERSIANN in rainfall detection also increases. - The systematic and random error decomposition in this area shows that PERSIANN has more difficulty in modeling the system and pattern of rainfall rather than to have bias due to rainfall uncertainties. The level of systematic error also considerably increases in heavier rainfalls. It is also important to note that PERSIANN error characteristics at each season varies due to the condition and rainfall patterns of that season which shows the necessity of seasonally different approach for the calibration of this product. Overall, we believe that different error component's analysis performed in this study, can substantially help any further local studies for post-calibration and bias reduction of PERSIANN estimations.

  15. Volumetric quantification of lung nodules in CT with iterative reconstruction (ASiR and MBIR).

    PubMed

    Chen, Baiyu; Barnhart, Huiman; Richard, Samuel; Robins, Marthony; Colsher, James; Samei, Ehsan

    2013-11-01

    Volume quantifications of lung nodules with multidetector computed tomography (CT) images provide useful information for monitoring nodule developments. The accuracy and precision of the volume quantification, however, can be impacted by imaging and reconstruction parameters. This study aimed to investigate the impact of iterative reconstruction algorithms on the accuracy and precision of volume quantification with dose and slice thickness as additional variables. Repeated CT images were acquired from an anthropomorphic chest phantom with synthetic nodules (9.5 and 4.8 mm) at six dose levels, and reconstructed with three reconstruction algorithms [filtered backprojection (FBP), adaptive statistical iterative reconstruction (ASiR), and model based iterative reconstruction (MBIR)] into three slice thicknesses. The nodule volumes were measured with two clinical software (A: Lung VCAR, B: iNtuition), and analyzed for accuracy and precision. Precision was found to be generally comparable between FBP and iterative reconstruction with no statistically significant difference noted for different dose levels, slice thickness, and segmentation software. Accuracy was found to be more variable. For large nodules, the accuracy was significantly different between ASiR and FBP for all slice thicknesses with both software, and significantly different between MBIR and FBP for 0.625 mm slice thickness with Software A and for all slice thicknesses with Software B. For small nodules, the accuracy was more similar between FBP and iterative reconstruction, with the exception of ASIR vs FBP at 1.25 mm with Software A and MBIR vs FBP at 0.625 mm with Software A. The systematic difference between the accuracy of FBP and iterative reconstructions highlights the importance of extending current segmentation software to accommodate the image characteristics of iterative reconstructions. In addition, a calibration process may help reduce the dependency of accuracy on reconstruction algorithms, such that volumes quantified from scans of different reconstruction algorithms can be compared. The little difference found between the precision of FBP and iterative reconstructions could be a result of both iterative reconstruction's diminished noise reduction at the edge of the nodules as well as the loss of resolution at high noise levels with iterative reconstruction. The findings do not rule out potential advantage of IR that might be evident in a study that uses a larger number of nodules or repeated scans.

  16. De-identification of patient notes with recurrent neural networks.

    PubMed

    Dernoncourt, Franck; Lee, Ji Young; Uzuner, Ozlem; Szolovits, Peter

    2017-05-01

    Patient notes in electronic health records (EHRs) may contain critical information for medical investigations. However, the vast majority of medical investigators can only access de-identified notes, in order to protect the confidentiality of patients. In the United States, the Health Insurance Portability and Accountability Act (HIPAA) defines 18 types of protected health information that needs to be removed to de-identify patient notes. Manual de-identification is impractical given the size of electronic health record databases, the limited number of researchers with access to non-de-identified notes, and the frequent mistakes of human annotators. A reliable automated de-identification system would consequently be of high value. We introduce the first de-identification system based on artificial neural networks (ANNs), which requires no handcrafted features or rules, unlike existing systems. We compare the performance of the system with state-of-the-art systems on two datasets: the i2b2 2014 de-identification challenge dataset, which is the largest publicly available de-identification dataset, and the MIMIC de-identification dataset, which we assembled and is twice as large as the i2b2 2014 dataset. Our ANN model outperforms the state-of-the-art systems. It yields an F1-score of 97.85 on the i2b2 2014 dataset, with a recall of 97.38 and a precision of 98.32, and an F1-score of 99.23 on the MIMIC de-identification dataset, with a recall of 99.25 and a precision of 99.21. Our findings support the use of ANNs for de-identification of patient notes, as they show better performance than previously published systems while requiring no manual feature engineering. © The Author 2016. Published by Oxford University Press on behalf of the American Medical Informatics Association. All rights reserved. For Permissions, please email: journals.permissions@oup.com

  17. A general study of techniques for ultraviolet astrophysical studies on space vehicles

    NASA Technical Reports Server (NTRS)

    Moos, H. W.; Fastie, W. G.; Davidsen, A. F.

    1977-01-01

    Recent accomplishments in three areas of UV instrumentation for space astronomy are discussed. These areas include reliable UV photometry, sensitive photon-detection techniques, and precise telescope pointing. Calibration facilities for spectrometers designed to operate in the spectral regions above 1200 A and down to 400 A are described which employ a series of diodes calibrated against electron synchrotron radiation as well as other radiometric standards. Improvements in photon-detection sensitivity achieved with the aid of pulse-counting electronics and multispectral detectors are reported, and the technique of precise subarcsecond telescope pointing is briefly noted. Some observational results are presented which demonstrate the advantages and precision of the instruments and techniques considered.

  18. GNSS Monitoring of Deformation within heavy civil infrastructure

    NASA Astrophysics Data System (ADS)

    Montillet, Jean-Philippe; Melbourne, Timothy; Szeliga, Walter; Schrock, Gavin

    2015-04-01

    The steady increase in precision simultaneous with the decreasing of continuous GPS monitoring has enabled the deployment of receivers for a host of new activities. Here we discuss the precision obtained from several multi-station installations operated over a five-year period on several heavy civil-engineered structures, including two earthen-fill dams and subsiding highway overpass damaged by seismic shaking. In the past 5 years, the Cascadia Hazards Institute (Pacific Northwest Geodetic Array) at Central Washington University together with the Washington department of public utilities (Land Survey) have been monitoring several structures around Seattle area including two dams (Howard Hansen and Tolt). One aim of this study is to test the use of continuous GNSS in order to detect any deformations due to rapid pool level rises or to monitor the safety of a structure when an Earthquake strikes it. In this study, data is processed using Real Time Kinematic GPS with short baseline (d < 500 m) and GPS daily position (PPP). However, multipath is the most limiting factor on accuracy for very precise positioning applications with GPS. It is very often present indoors and outdoors, especially in narrow valleys with a limited view of the sky. As a result, multipath can amount to an error of a few centimetres. Unfortunately, the accuracy requirements of precision deformation monitoring are generally at the sub centimetre level, which is presently a big challenge on an epoch-by-epoch basis with regular, carrier phase techniques. Thus, it needs to be properly mitigated. In this study, several stations are set up on the dams (4 stations on the Tolt reservoir and 10 stations on the Howard Hansen dam), and spatial filtering can then be used to mitigate multipath. In addition, several signal processing techniques are also investigated (i.e. Empirical mode decomposition, sidereal filtering, adaptive filtering). RTK GPS should allow to monitor rapid deformations, whereas GPS daily position is used to detect long-term deformations such as the pool level rises due to the melting of ice cap on surrounding mountains. Note that RTK measurements are processed with the MIT software TRACK and the GPS daily positions estimated with GAMIT-GLOBK.

  19. Using known map category marginal frequencies to improve estimates of thematic map accuracy

    NASA Technical Reports Server (NTRS)

    Card, D. H.

    1982-01-01

    By means of two simple sampling plans suggested in the accuracy-assessment literature, it is shown how one can use knowledge of map-category relative sizes to improve estimates of various probabilities. The fact that maximum likelihood estimates of cell probabilities for the simple random sampling and map category-stratified sampling were identical has permitted a unified treatment of the contingency-table analysis. A rigorous analysis of the effect of sampling independently within map categories is made possible by results for the stratified case. It is noted that such matters as optimal sample size selection for the achievement of a desired level of precision in various estimators are irrelevant, since the estimators derived are valid irrespective of how sample sizes are chosen.

  20. A Novel Approach towards Medical Entity Recognition in Chinese Clinical Text

    PubMed Central

    Yu, Jian

    2017-01-01

    Medical entity recognition, a basic task in the language processing of clinical data, has been extensively studied in analyzing admission notes in alphabetic languages such as English. However, much less work has been done on nonstructural texts that are written in Chinese, or in the setting of differentiation of Chinese drug names between traditional Chinese medicine and Western medicine. Here, we propose a novel cascade-type Chinese medication entity recognition approach that aims at integrating the sentence category classifier from a support vector machine and the conditional random field-based medication entity recognition. We hypothesized that this approach could avoid the side effects of abundant negative samples and improve the performance of the named entity recognition from admission notes written in Chinese. Therefore, we applied this approach to a test set of 324 Chinese-written admission notes with manual annotation by medical experts. Our data demonstrated that this approach had a score of 94.2% in precision, 92.8% in recall, and 93.5% in F-measure for the recognition of traditional Chinese medicine drug names and 91.2% in precision, 92.6% in recall, and 91.7% F-measure for the recognition of Western medicine drug names. The differences in F-measure were significant compared with those in the baseline systems. PMID:29065612

  1. Context-Dependent Piano Music Transcription With Convolutional Sparse Coding

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cogliati, Andrea; Duan, Zhiyao; Wohlberg, Brendt

    This study presents a novel approach to automatic transcription of piano music in a context-dependent setting. This approach employs convolutional sparse coding to approximate the music waveform as the summation of piano note waveforms (dictionary elements) convolved with their temporal activations (onset transcription). The piano note waveforms are pre-recorded for the specific piano to be transcribed in the specific environment. During transcription, the note waveforms are fixed and their temporal activations are estimated and post-processed to obtain the pitch and onset transcription. This approach works in the time domain, models temporal evolution of piano notes, and estimates pitches and onsetsmore » simultaneously in the same framework. Finally, experiments show that it significantly outperforms a state-of-the-art music transcription method trained in the same context-dependent setting, in both transcription accuracy and time precision, in various scenarios including synthetic, anechoic, noisy, and reverberant environments.« less

  2. Context-Dependent Piano Music Transcription With Convolutional Sparse Coding

    DOE PAGES

    Cogliati, Andrea; Duan, Zhiyao; Wohlberg, Brendt

    2016-08-04

    This study presents a novel approach to automatic transcription of piano music in a context-dependent setting. This approach employs convolutional sparse coding to approximate the music waveform as the summation of piano note waveforms (dictionary elements) convolved with their temporal activations (onset transcription). The piano note waveforms are pre-recorded for the specific piano to be transcribed in the specific environment. During transcription, the note waveforms are fixed and their temporal activations are estimated and post-processed to obtain the pitch and onset transcription. This approach works in the time domain, models temporal evolution of piano notes, and estimates pitches and onsetsmore » simultaneously in the same framework. Finally, experiments show that it significantly outperforms a state-of-the-art music transcription method trained in the same context-dependent setting, in both transcription accuracy and time precision, in various scenarios including synthetic, anechoic, noisy, and reverberant environments.« less

  3. In vivo miniature robots for natural orifice surgery: State of the art and future perspectives.

    PubMed

    Tiwari, Manish M; Reynoso, Jason F; Lehman, Amy C; Tsang, Albert W; Farritor, Shane M; Oleynikov, Dmitry

    2010-06-27

    Natural orifice translumenal endoscopic surgery (NOTES) is the integration of laparoscopic minimally invasive surgery techniques with endoscopic technology. Despite the advances in NOTES technology, the approach presents several unique instrumentation and technique-specific challenges. Current flexible endoscopy platforms for NOTES have several drawbacks including limited stability, triangulation and dexterity, and lack of adequate visualization, suggesting the need for new and improved instrumentation for this approach. Much of the current focus is on the development of flexible endoscopy platforms that incorporate robotic technology. An alternative approach to access the abdominal viscera for either a laparoscopic or NOTES procedure is the use of small robotic devices that can be implanted in an intracorporeal manner. Multiple, independent, miniature robots can be simultaneously inserted into the abdominal cavity to provide a robotic platform for NOTES surgery. The capabilities of the robots include imaging, retraction, tissue and organ manipulation, and precise maneuverability in the abdominal cavity. Such a platform affords several advantages including enhanced visualization, better surgical dexterity and improved triangulation for NOTES. This review discusses the current status and future perspectives of this novel miniature robotics platform for the NOTES approach. Although these technologies are still in pre-clinical development, a miniature robotics platform provides a unique method for addressing the limitations of minimally invasive surgery, and NOTES in particular.

  4. Insufficient filling of vacuum tubes as a cause of microhemolysis and elevated serum lactate dehydrogenase levels. Use of a data-mining technique in evaluation of questionable laboratory test results.

    PubMed

    Tamechika, Yoshie; Iwatani, Yoshinori; Tohyama, Kaoru; Ichihara, Kiyoshi

    2006-01-01

    Experienced physicians noted unexpectedly elevated concentrations of lactate dehydrogenase in some patient samples, but quality control specimens showed no bias. To evaluate this problem, we used a "latent reference individual extraction method", designed to obtain reference intervals from a laboratory database by excluding individuals who have abnormal results for basic analytes other than the analyte in question, in this case lactate dehydrogenase. The reference interval derived for the suspected year was 264-530 U/L, while that of the previous year was 248-495 U/L. The only change we found was the introduction of an order entry system, which requests precise sampling volumes rather than complete filling of vacuum tubes. The effect of vacuum persistence was tested using ten freshly drawn blood samples. Compared with complete filling, 1/5 filling resulted in average elevations of lactate dehydrogenase, aspartic aminotransferase, and potassium levels of 8.0%, 3.8%, and 3.4%, respectively (all p<0.01). Microhemolysis was confirmed using a urine stick method. The length of time before centrifugation determined the degree of hemolysis, while vacuum during centrifugation did not affect it. Microhemolysis is the probable cause of the suspected pseudo-elevation noted by the physicians. Data-mining methodology represents a valuable tool for monitoring long-term bias in laboratory results.

  5. On the relation between pitch and level.

    PubMed

    Zheng, Yi; Brette, Romain

    2017-05-01

    Pitch is the perceptual dimension along which musical notes are ordered from low to high. It is often described as the perceptual correlate of the periodicity of the sound's waveform. Previous reports have shown that pitch can depend slightly on sound level. We wanted to verify that these observations reflect genuine changes in perceived pitch, and were not due to procedural factors or confusion between dimensions of pitch and level. We first conducted a systematic pitch matching task and confirmed that the pitch of low frequency pure tones, but not complex tones, decreases by an amount equivalent to a change in frequency of more than half a semitone when level increases. We then showed that the structure of pitch shifts is anti-symmetric and transitive, as expected for changes in pitch. We also observed shifts in the same direction (although smaller) in an interval matching task. Finally, we observed that musicians are more precise in pitch matching tasks than non-musicians but show the same average shifts with level. These combined experiments confirm that the pitch of low frequency pure tones depends weakly but systematically on level. These observations pose a challenge to current theories of pitch. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Note: electronic circuit for two-way time transfer via a single coaxial cable with picosecond accuracy and precision.

    PubMed

    Prochazka, Ivan; Kodet, Jan; Panek, Petr

    2012-11-01

    We have designed, constructed, and tested the overall performance of the electronic circuit for the two-way time transfer between two timing devices over modest distances with sub-picosecond precision and a systematic error of a few picoseconds. The concept of the electronic circuit enables to carry out time tagging of pulses of interest in parallel to the comparison of the time scales of these timing devices. The key timing parameters of the circuit are: temperature change of the delay is below 100 fs/K, timing stability time deviation better than 8 fs for averaging time from minutes to hours, sub-picosecond time transfer precision, and a few picoseconds time transfer accuracy.

  7. The Marriage of Two Opposing Cultures

    ERIC Educational Resources Information Center

    Loubriel, Luis

    2007-01-01

    With a heavy dominance on its technical/empirical aspects, the segmented performance, pedagogy, and assessment of Western classical music is undermining its goal of creating art with precision, style, and expressive beauty. This segmentation has its roots in the quantitative assessment processes found in music education and in the note-perfect…

  8. Concepts. The Journal of Defense Systems Acquisition Management. Summer 1981. Volume 4, Number 3.

    DTIC Science & Technology

    1981-01-01

    Performance FREQUENCY POWER OUTPUT GIZMO MODEL 25 0-50 MHZ SATISFACTORY 50-125 MHZ UNSATISFACTORY ASTROMATICS MODEL C 0-50 MHZ SATISFACTORY 50-125 MHZ...MHZ) GIZMO ----- ASTROMATICS- NOTES: 1. Diagrams excellent for portraying precise technical relationships. 2. Diagrams are economical means of

  9. Precision in the Global War on Terror: Inciting Muslims Through the War of Ideas

    DTIC Science & Technology

    2008-04-01

    Lebanese Christian musi- cian Marcel Khalifa was put on trial for including lyrics about the Prophet Yusuf (Joseph) in his songs. Westerners will...then concludes his essay by noting Ambassador Hume Horan’s comment that there are no Arab “Christofer Dawsons . . . and Martin Bubers

  10. Mentoring, Mentors and Proteges.

    ERIC Educational Resources Information Center

    Peper, John B.

    This paper reports on research into the concept of mentoring from many educational perspectives, based on six papers presented at the Annual Meeting of the American Educational Research Association in April 1994. The paper notes that mentoring is a slippery concept, without a precise operational definition; definitions used in the six papers are…

  11. The Navy Precision Optical Interferometer (NPOI): An Update

    DTIC Science & Technology

    2013-01-01

    IOTA1. Since that time, four of these have closed: I2T, COAST, GI2T, and IOTA . Three others have opened and closed: PTI, MIRA-I.2,2 and 1Corresponding...public release; distribution unlimited 13. SUPPLEMENTARY NOTES Journal of Astronomical Instrumentation 14. ABSTRACT 15. SUBJECT TERMS 16. SECURITY

  12. Systematic Molecular Phenotyping: A Path Toward Precision Emergency Medicine?

    PubMed

    Limkakeng, Alexander T; Monte, Andrew A; Kabrhel, Christopher; Puskarich, Michael; Heitsch, Laura; Tsalik, Ephraim L; Shapiro, Nathan I

    2016-10-01

    Precision medicine is an emerging approach to disease treatment and prevention that considers variability in patient genes, environment, and lifestyle. However, little has been written about how such research impacts emergency care. Recent advances in analytical techniques have made it possible to characterize patients in a more comprehensive and sophisticated fashion at the molecular level, promising highly individualized diagnosis and treatment. Among these techniques are various systematic molecular phenotyping analyses (e.g., genomics, transcriptomics, proteomics, and metabolomics). Although a number of emergency physicians use such techniques in their research, widespread discussion of these approaches has been lacking in the emergency care literature and many emergency physicians may be unfamiliar with them. In this article, we briefly review the underpinnings of such studies, note how they already impact acute care, discuss areas in which they might soon be applied, and identify challenges in translation to the emergency department (ED). While such techniques hold much promise, it is unclear whether the obstacles to translating their findings to the ED will be overcome in the near future. Such obstacles include validation, cost, turnaround time, user interface, decision support, standardization, and adoption by end-users. © 2016 by the Society for Academic Emergency Medicine.

  13. Systematic Molecular Phenotyping: A Path Towards Precision Emergency Medicine?

    PubMed Central

    Limkakeng, Alexander T.; Monte, Andrew; Kabrhel, Christopher; Puskarich, Michael; Heitsch, Laura; Tsalik, Ephraim L.; Shapiro, Nathan I.

    2016-01-01

    Precision medicine is an emerging approach to disease treatment and prevention that considers variability in patient genes, environment, and lifestyle. However, little has been written about how such research impacts emergency care. Recent advances in analytical techniques have made it possible to characterize patients in a more comprehensive and sophisticated fashion at the molecular level, promising highly individualized diagnosis and treatment. Among these techniques are various systematic molecular phenotyping analyses (e.g., genomics, transcriptomics, proteomics, and metabolomics). Although a number of emergency physicians use such techniques in their research, widespread discussion of these approaches has been lacking in the emergency care literature and many emergency physicians may be unfamiliar with them. In this article, we briefly review the underpinnings of such studies, note how they already impact acute care, discuss areas in which they might soon be applied, and identify challenges in translation to the emergency department. While such techniques hold much promise, it is unclear whether the obstacles to translating their findings to the emergency department will be overcome in the near future. Such obstacles include validation, cost, turnaround time, user interface, decision support, standardization, and adoption by end users. PMID:27288269

  14. Bootstrapping a de-identification system for narrative patient records: cost-performance tradeoffs.

    PubMed

    Hanauer, David; Aberdeen, John; Bayer, Samuel; Wellner, Benjamin; Clark, Cheryl; Zheng, Kai; Hirschman, Lynette

    2013-09-01

    We describe an experiment to build a de-identification system for clinical records using the open source MITRE Identification Scrubber Toolkit (MIST). We quantify the human annotation effort needed to produce a system that de-identifies at high accuracy. Using two types of clinical records (history and physical notes, and social work notes), we iteratively built statistical de-identification models by annotating 10 notes, training a model, applying the model to another 10 notes, correcting the model's output, and training from the resulting larger set of annotated notes. This was repeated for 20 rounds of 10 notes each, and then an additional 6 rounds of 20 notes each, and a final round of 40 notes. At each stage, we measured precision, recall, and F-score, and compared these to the amount of annotation time needed to complete the round. After the initial 10-note round (33min of annotation time) we achieved an F-score of 0.89. After just over 8h of annotation time (round 21) we achieved an F-score of 0.95. Number of annotation actions needed, as well as time needed, decreased in later rounds as model performance improved. Accuracy on history and physical notes exceeded that of social work notes, suggesting that the wider variety and contexts for protected health information (PHI) in social work notes is more difficult to model. It is possible, with modest effort, to build a functioning de-identification system de novo using the MIST framework. The resulting system achieved performance comparable to other high-performing de-identification systems. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  15. SmallSat Precision Navigation with Low-Cost MEMS IMU Swarms

    NASA Technical Reports Server (NTRS)

    Christian, John; Bishop, Robert; Martinez, Andres; Petro, Andrew

    2015-01-01

    The continued advancement of small satellite-based science missions requires the solution to a number of important technical challenges. Of particular note is that small satellite missions are characterized by tight constraints on cost, mass, power, and volume that make them unable to fly the high-quality Inertial Measurement Units (IMUs) required for orbital missions demanding precise orientation and positioning. Instead, small satellite missions typically fly low-cost Micro-Electro-Mechanical System (MEMS) IMUs. Unfortunately, the performance characteristics of these MEMS IMUs make them ineffectual in many spaceflight applications when employed in a single IMU system configuration.

  16. Information's role in the estimation of chaotic signals

    NASA Astrophysics Data System (ADS)

    Drake, Daniel Fred

    1998-11-01

    Researchers have proposed several methods designed to recover chaotic signals from noise-corrupted observations. While the methods vary, their qualitative performance does not: in low levels of noise all methods effectively recover the underlying signal; in high levels of noise no method can recover the underlying signal to any meaningful degree of accuracy. Of the methods proposed to date, all represent sub-optimal estimators. So: Is the inability to recover the signal in high noise levels simply a consequence of estimator sub-optimality? Or is estimator failure actually a manifestation of some intrinsic property of chaos itself? These questions are answered by deriving an optimal estimator for a class of chaotic systems and noting that it, too, fails in high levels of noise. An exact, closed- form expression for the estimator is obtained for a class of chaotic systems whose signals are solutions to a set of linear (but noncausal) difference equations. The existence of this linear description circumvents the difficulties normally encountered when manipulating the nonlinear (but causal) expressions that govern. chaotic behavior. The reason why even the optimal estimator fails to recover underlying chaotic signals in high levels of noise has its roots in information theory. At such noise levels, the mutual information linking the corrupted observations to the underlying signal is essentially nil, reducing the estimator to a simple guessing strategy based solely on a priori statistics. Entropy, long the common bond between information theory and dynamical systems, is actually one aspect of a far more complete characterization of information sources: the rate distortion function. Determining the rate distortion function associated with the class of chaotic systems considered in this work provides bounds on estimator performance in high levels of noise. Finally, a slight modification of the linear description leads to a method of synthesizing on limited precision platforms ``pseudo-chaotic'' sequences that mimic true chaotic behavior to any finite degree of precision and duration. The use of such a technique in spread-spectrum communications is considered.

  17. New Methods for the Analysis of Fat-Soluble Vitamins in Infant Formula and Adult Nutritionals.

    PubMed

    Gilliland, Don

    2016-01-01

    The AOAC Stakeholder Panel on Infant Formula and Adult Nutritionals (SPIFAN) defined fat-soluble vitamins (FSVs) to include vitamins A, D, E, and K. The levels of FSVs have been closely scrutinized because of a number of factors, including nutrition value especially in foods used to provide sole-source nutrition and the potential for health risks associated with content both below and above recommended levels. Stricter scrutiny and emphasis on nutrient-level compliance with regulatory requirements placed an increased demand on analytical methods that were fit-for-purpose, provided accurate and precise results. Over time, compendial methods have been developed and published by organizations such as AOAC INTERNATIONAL, the European Committee for Standardization, the International Dairy Federation, and the International Organization for Standardization, among others. In general, these methods have shown adequate precision for regulatory compliance based on example food matrixes for which they were designed. However, method evaluation for infant formulas and adult nutritional products was limited to very few matrixes within these categories. As such, method applicability gaps were noted and correlated with more complicated or diverse product matrixes. AOAC undertook the task of modernizing test methods for the determination of nutrients in infant formulas and in adult nutritional products formulated specifically for both healthy adults and those requiring specific nutritional intake. Composition of products in this category continued to evolve, which in turn presented increasing and new challenges to analytical methodology. A summary of a new generation of candidate compendial methods for determination of FSVs in these matrixes, identified by SPIFAN, is presented here.

  18. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nahar, Sultana N., E-mail: nahar@astronomy.ohio-state.edu

    The atomic parameters–oscillator strengths, line strengths, radiative decay rates (A), and lifetimes–for fine structure transitions of electric dipole (E1) type for the astrophysically abundant ion Ne IV are presented. The results include 868 fine structure levels with n≤ 10, l≤ 9, and 1/2≤J≤ 19/2 of even and odd parities, and the corresponding 83,767 E1 transitions. The calculations were carried out using the relativistic Breit–Pauli R-matrix method in the close coupling approximation. The transitions have been identified spectroscopically using an algorithm based on quantum defect analysis and other criteria. The calculated energies agree with the 103 observed and identified energies to withinmore » 3% or better for most of the levels. Some larger differences are also noted. The A-values show good to fair agreement with the very limited number of available transitions in the table compiled by NIST, but show very good agreement with the latest published multi-configuration Hartree–Fock calculations. The present transitions should be useful for diagnostics as well as for precise and complete spectral modeling in the soft X-ray to infra-red regions of astrophysical and laboratory plasmas. -- Highlights: •The first application of BPRM method for accurate E1 transitions in Ne IV is reported. •Amount of atomic data (n going up to 10) is complete for most practical applications. •The calculated energies are in very good agreement with most observed levels. •Very good agreement of A-values and lifetimes with other relativistic calculations. •The results should provide precise nebular abundances, chemical evolution etc.« less

  19. Identifying Falls Risk Screenings Not Documented with Administrative Codes Using Natural Language Processing

    PubMed Central

    Zhu, Vivienne J; Walker, Tina D; Warren, Robert W; Jenny, Peggy B; Meystre, Stephane; Lenert, Leslie A

    2017-01-01

    Quality reporting that relies on coded administrative data alone may not completely and accurately depict providers’ performance. To assess this concern with a test case, we developed and evaluated a natural language processing (NLP) approach to identify falls risk screenings documented in clinical notes of patients without coded falls risk screening data. Extracting information from 1,558 clinical notes (mainly progress notes) from 144 eligible patients, we generated a lexicon of 38 keywords relevant to falls risk screening, 26 terms for pre-negation, and 35 terms for post-negation. The NLP algorithm identified 62 (out of the 144) patients who falls risk screening documented only in clinical notes and not coded. Manual review confirmed 59 patients as true positives and 77 patients as true negatives. Our NLP approach scored 0.92 for precision, 0.95 for recall, and 0.93 for F-measure. These results support the concept of utilizing NLP to enhance healthcare quality reporting. PMID:29854264

  20. Speed, Accuracy, and Serial Order in Sequence Production

    ERIC Educational Resources Information Center

    Pfordresher, Peter Q.; Palmer, Caroline; Jungers, Melissa K.

    2007-01-01

    The production of complex sequences like music or speech requires the rapid and temporally precise production of events (e.g., notes and chords), often at fast rates. Memory retrieval in these circumstances may rely on the simultaneous activation of both the current event and the surrounding context (Lashley, 1951). We describe an extension to a…

  1. Efficient identification of nationally mandated reportable cancer cases using natural language processing and machine learning.

    PubMed

    Osborne, John D; Wyatt, Matthew; Westfall, Andrew O; Willig, James; Bethard, Steven; Gordon, Geoff

    2016-11-01

    To help cancer registrars efficiently and accurately identify reportable cancer cases. The Cancer Registry Control Panel (CRCP) was developed to detect mentions of reportable cancer cases using a pipeline built on the Unstructured Information Management Architecture - Asynchronous Scaleout (UIMA-AS) architecture containing the National Library of Medicine's UIMA MetaMap annotator as well as a variety of rule-based UIMA annotators that primarily act to filter out concepts referring to nonreportable cancers. CRCP inspects pathology reports nightly to identify pathology records containing relevant cancer concepts and combines this with diagnosis codes from the Clinical Electronic Data Warehouse to identify candidate cancer patients using supervised machine learning. Cancer mentions are highlighted in all candidate clinical notes and then sorted in CRCP's web interface for faster validation by cancer registrars. CRCP achieved an accuracy of 0.872 and detected reportable cancer cases with a precision of 0.843 and a recall of 0.848. CRCP increases throughput by 22.6% over a baseline (manual review) pathology report inspection system while achieving a higher precision and recall. Depending on registrar time constraints, CRCP can increase recall to 0.939 at the expense of precision by incorporating a data source information feature. CRCP demonstrates accurate results when applying natural language processing features to the problem of detecting patients with cases of reportable cancer from clinical notes. We show that implementing only a portion of cancer reporting rules in the form of regular expressions is sufficient to increase the precision, recall, and speed of the detection of reportable cancer cases when combined with off-the-shelf information extraction software and machine learning. © The Author 2016. Published by Oxford University Press on behalf of the American Medical Informatics Association. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  2. Note taking, review, memory, and comprehension.

    PubMed

    Bohay, Mark; Blakely, Daniel P; Tamplin, Andrea K; Radvansky, Gabriel A

    2011-01-01

    In previous work assessing memory at various levels of representation, namely the surface form, textbase, and situation model levels, participants read texts but were otherwise not actively engaged with the texts. The current study tested the influence of active engagement with the material via note taking, along with the opportunity to review such notes, and the modality of presentation (text vs. spoken). The influence of these manipulations was assessed both immediately and 1 week later. In Experiment 1 participants read a text, whereas in Experiment 2 participants watched a video recording of the material being read as a lecture. For each experiment the opportunity to take notes was manipulated within participants, and the opportunity to review these notes before the test was manipulated between participants. Note taking improved performance at the situation model level in both experiments, although there was also some suggestion of benefit for the surface form. Thus, active engagement with material, such as note taking, appears to have the greatest benefit at the deeper levels of understanding.

  3. Towards the unification of inference structures in medical diagnostic tasks.

    PubMed

    Mira, J; Rives, J; Delgado, A E; Martínez, R

    1998-01-01

    The central purpose of artificial intelligence applied to medicine is to develop models for diagnosis and therapy planning at the knowledge level, in the Newell sense, and software environments to facilitate the reduction of these models to the symbol level. The usual methodology (KADS, Common-KADS, GAMES, HELIOS, Protégé, etc) has been to develop libraries of generic tasks and reusable problem-solving methods with explicit ontologies. The principal problem which clinicians have with these methodological developments concerns the diversity and complexity of new terms whose meaning is not sufficiently clear, precise, unambiguous and consensual for them to be accessible in the daily clinical environment. As a contribution to the solution of this problem, we develop in this article the conjecture that one inference structure is enough to describe the set of analysis tasks associated with medical diagnoses. To this end, we first propose a modification of the systematic diagnostic inference scheme to obtain an analysis generic task and then compare it with the monitoring and the heuristic classification task inference schemes using as comparison criteria the compatibility of domain roles (data structures), the similarity in the inferences, and the commonality in the set of assumptions which underlie the functionally equivalent models. The equivalences proposed are illustrated with several examples. Note that though our ongoing work aims to simplify the methodology and to increase the precision of the terms used, the proposal presented here should be viewed more in the nature of a conjecture.

  4. The influence of prior knowledge on the retrieval-directed function of note taking in prior knowledge activation.

    PubMed

    Wetzels, Sandra A J; Kester, Liesbeth; van Merriënboer, Jeroen J G; Broers, Nick J

    2011-06-01

    Prior knowledge activation facilitates learning. Note taking during prior knowledge activation (i.e., note taking directed at retrieving information from memory) might facilitate the activation process by enabling learners to build an external representation of their prior knowledge. However, taking notes might be less effective in supporting prior knowledge activation if available prior knowledge is limited. This study investigates the effects of the retrieval-directed function of note taking depending on learners' level of prior knowledge. It is hypothesized that the effectiveness of note taking is influenced by the amount of prior knowledge learners already possess. Sixty-one high school students participated in this study. A prior knowledge test was used to ascertain differences in level of prior knowledge and assign participants to a low or a high prior knowledge group. A 2×2 factorial design was used to investigate the effects of note taking during prior knowledge activation (yes, no) depending on learners' level of prior knowledge (low, high) on mental effort, performance, and mental efficiency. Note taking during prior knowledge activation lowered mental effort and increased mental efficiency for high prior knowledge learners. For low prior knowledge learners, note taking had the opposite effect on mental effort and mental efficiency. The effects of the retrieval-directed function of note taking are influenced by learners' level of prior knowledge. Learners with high prior knowledge benefit from taking notes while activating prior knowledge, whereas note taking has no beneficial effects for learners with limited prior knowledge. ©2010 The British Psychological Society.

  5. The Indeterminate Case of Classical Static Friction When Coupled with Tension

    ERIC Educational Resources Information Center

    Hahn, Kenneth D.; Russell, Jacob M.

    2018-01-01

    It has been noted that the static friction force poses challenges for students and, at times, even their instructors. Unlike the gravitational force, which has a precise and unambiguous magnitude (F[subscript G] = mg), the magnitude and direction of the static friction force depend on other forces at play. Friction can be understood rather well in…

  6. Three Cheers for Language: A Closer Examination of a Widely Cited Study of Nonverbal Communication.

    ERIC Educational Resources Information Center

    Lapakko, David

    1997-01-01

    Focuses on applications of a widely cited empirical study in the communication field--A. Mehrabian and S. Ferris' 1967 study that inferred that communication is 7% verbal, 38% vocal, and 55% facial. Notes that these applications overlook important limitations which do not warrant formulation of a precise numerical formula. Discusses lessons…

  7. Teaching Macroeconomics to the Visually Impaired: New Tactile Methods, Verbal Precision, and Small Groups

    ERIC Educational Resources Information Center

    Naples, Michele I.

    2017-01-01

    Visually-impaired students require tailored pedagogies to ensure their instruction is as high quality as for sighted students. They follow board work during class by referring to typed class notes provided ahead of time via a Braille reader, and in-class small groups solving problems create an inclusive "esprit de corps" and promote…

  8. Motivational State, Reward Value, and Pavlovian Cues Differentially Affect Skilled Forelimb Grasping in Rats

    ERIC Educational Resources Information Center

    Mosberger, Alice C.; de Clauser, Larissa; Kasper, Hansjörg; Schwab, Martin E.

    2016-01-01

    Motor skills represent high-precision movements performed at optimal speed and accuracy. Such motor skills are learned with practice over time. Besides practice, effects of motivation have also been shown to influence speed and accuracy of movements, suggesting that fast movements are performed to maximize gained reward over time as noted in…

  9. In Quest of Fame at the 4Cs

    ERIC Educational Resources Information Center

    Livatino, Mel

    2006-01-01

    Mel Livatino had stopped attending Conferences on College Composition and Communication (4Cs), but this year one came to his hometown, so he attended and now reports back. Where once the 4Cs had offered helpful insights into teaching kids how to write, today frivolity and radicalism reign. Professor Livatino's notes paint a very precise, largely…

  10. Developing and evaluating an automated appendicitis risk stratification algorithm for pediatric patients in the emergency department.

    PubMed

    Deleger, Louise; Brodzinski, Holly; Zhai, Haijun; Li, Qi; Lingren, Todd; Kirkendall, Eric S; Alessandrini, Evaline; Solti, Imre

    2013-12-01

    To evaluate a proposed natural language processing (NLP) and machine-learning based automated method to risk stratify abdominal pain patients by analyzing the content of the electronic health record (EHR). We analyzed the EHRs of a random sample of 2100 pediatric emergency department (ED) patients with abdominal pain, including all with a final diagnosis of appendicitis. We developed an automated system to extract relevant elements from ED physician notes and lab values and to automatically assign a risk category for acute appendicitis (high, equivocal, or low), based on the Pediatric Appendicitis Score. We evaluated the performance of the system against a manually created gold standard (chart reviews by ED physicians) for recall, specificity, and precision. The system achieved an average F-measure of 0.867 (0.869 recall and 0.863 precision) for risk classification, which was comparable to physician experts. Recall/precision were 0.897/0.952 in the low-risk category, 0.855/0.886 in the high-risk category, and 0.854/0.766 in the equivocal-risk category. The information that the system required as input to achieve high F-measure was available within the first 4 h of the ED visit. Automated appendicitis risk categorization based on EHR content, including information from clinical notes, shows comparable performance to physician chart reviewers as measured by their inter-annotator agreement and represents a promising new approach for computerized decision support to promote application of evidence-based medicine at the point of care.

  11. A new method to precisely control the depth of percutaneous screws into the pedicle by counting the rotation number of the screw with low radiation exposure: technical note.

    PubMed

    Li, Xu; Zhang, Feng; Zhang, Wenzhi; Shang, Xifu; Han, Jintao; Liu, Pengfei

    2017-03-01

    Technique note. To report a new method for precisely controlling the depth of percutaneous pedicle screws (PPS)-without radiation exposure to surgeons and less fluoroscopy exposure to patients than with conventional methods. PPS is widely used in minimal invasive spine surgery; the advantages include reduced muscle damage, pain, and hospital stays. However, placement of PPS demands repeated checking with fluoroscopy. Thus, radiation exposure is considerable for both surgeons and patients. The PPS depth was determined by counting rotations of the screws. The distance between screw threads can be measured for particular screws; thus, full rotations of the PPS results in the screw advancing in the pedicle the distance between screw threads. To fully insert screws into the pedicle, the number of full rotations is equal to the number of threads in the PPS. We applied this technique in 58 patients with thoracolumbar fracture. The position and depth of the screws was checked during the operation with the C-arm and after operation by anteroposterior X-ray film or computed tomography. No additional procedures were required to correct the screws; we observed no neurological deficits or malpositioning of the screws. In the screw placement procedure, the radiation exposure for surgeons is zero, and the patient is well protected from extensive radiation exposure. This method of counting rotation of screws is a safe way to precisely determine the depth of PPS in the placement procedure. IV.

  12. The DataCube Server. Animate Agent Project Working Note 2, Version 1.0

    DTIC Science & Technology

    1993-11-01

    before this can be called a histogram of all the needed levels must be made and their one band images must be made. Note if a levels backprojection...will not be used then the level does not need to be histogrammed. Any points outside the active region in a levels backprojection will be undefined...this can be called a histogram of all the needed levels must be made and their one band images must be made. Note if a levels backprojection will not

  13. SHRIMP-SI Multiple Sulfur Isotope Analysis of Sulfides from Brazilian Deposits: Analytical Capability to Resolve Single Grain Textural Complexities and Distinct Sulfur Sources

    NASA Astrophysics Data System (ADS)

    Ireland, T. R.; Teles, G. D. S.; Chemale, F., Jr.; Avila, J.

    2016-12-01

    The Archean atmosphere is thought to be several times more reducing than the present day atmosphere, and the occurrence of Mass Independent Fractionation of Sulfur isotopes (MIF-S) in sulfides of sedimentary and volcanogenic rocks older than 2.45 Ga reinforces it. The most accepted mechanism to generate MIF-S requires photochemical reactions with volcanogenic SO2 in an anoxic atmosphere (O2 levels <10-5 PAL). The identification of MIF-S, noted as Δ33S and Δ36S, requires precise measurements of less abundant 33S and 36S isotopes, which were first attained by bulk isotope analyses. However, in-situ analysis has become essential, as many of ancient sulfide samples have suffered post-depositional processes, and their primary isotopic signature from the atmosphere are now overprinted by mass-dependent fractionation processes. High-precision and resolution in situ measurements of 32S, 33S, 34S and 36S in sulfides can be achieved by SHRIMP-SI, which allows isotopic determinations with internal errors better than 0.05‰ for Δ33S and 0.2‰ for Δ36S (2SE), and reproducibility about 0.1‰ for Δ33S and better than 0.5‰ for Δ36S (2SD). Examples of the SHRIMP-SI capability are provided by multiple sulfur isotope analysis of samples from Brazil, the Au-(U) and pyrite deposits of Jacobina Basin and the massive sulfide deposits of the 3.3 Ga Mundo Novo Greenstone Belt. The level of precision and spatial resolution achievable with SHRIMP-SI allowed the isotopic distinction between sedimentary and post-depositional pyrites in Jacobina Basin, as well as the identification of different sulfur sources in the Mundo Novo Greenstone Belt VMS deposits.

  14. Development and evaluation of a de-identification procedure for a case register sourced from mental health electronic records.

    PubMed

    Fernandes, Andrea C; Cloete, Danielle; Broadbent, Matthew T M; Hayes, Richard D; Chang, Chin-Kuo; Jackson, Richard G; Roberts, Angus; Tsang, Jason; Soncul, Murat; Liebscher, Jennifer; Stewart, Robert; Callard, Felicity

    2013-07-11

    Electronic health records (EHRs) provide enormous potential for health research but also present data governance challenges. Ensuring de-identification is a pre-requisite for use of EHR data without prior consent. The South London and Maudsley NHS Trust (SLaM), one of the largest secondary mental healthcare providers in Europe, has developed, from its EHRs, a de-identified psychiatric case register, the Clinical Record Interactive Search (CRIS), for secondary research. We describe development, implementation and evaluation of a bespoke de-identification algorithm used to create the register. It is designed to create dictionaries using patient identifiers (PIs) entered into dedicated source fields and then identify, match and mask them (with ZZZZZ) when they appear in medical texts. We deemed this approach would be effective, given high coverage of PI in the dedicated fields and the effectiveness of the masking combined with elements of a security model. We conducted two separate performance tests i) to test performance of the algorithm in masking individual true PIs entered in dedicated fields and then found in text (using 500 patient notes) and ii) to compare the performance of the CRIS pattern matching algorithm with a machine learning algorithm, called the MITRE Identification Scrubber Toolkit - MIST (using 70 patient notes - 50 notes to train, 20 notes to test on). We also report any incidences of potential breaches, defined by occurrences of 3 or more true or apparent PIs in the same patient's notes (and in an additional set of longitudinal notes for 50 patients); and we consider the possibility of inferring information despite de-identification. True PIs were masked with 98.8% precision and 97.6% recall. As anticipated, potential PIs did appear, owing to misspellings entered within the EHRs. We found one potential breach. In a separate performance test, with a different set of notes, CRIS yielded 100% precision and 88.5% recall, while MIST yielded a 95.1% and 78.1%, respectively. We discuss how we overcome the realistic possibility - albeit of low probability - of potential breaches through implementation of the security model. CRIS is a de-identified psychiatric database sourced from EHRs, which protects patient anonymity and maximises data available for research. CRIS demonstrates the advantage of combining an effective de-identification algorithm with a carefully designed security model. The paper advances much needed discussion of EHR de-identification - particularly in relation to criteria to assess de-identification, and considering the contexts of de-identified research databases when assessing the risk of breaches of confidential patient information.

  15. Fast, precise, and widely tunable frequency control of an optical parametric oscillator referenced to a frequency comb.

    PubMed

    Prehn, Alexander; Glöckner, Rosa; Rempe, Gerhard; Zeppenfeld, Martin

    2017-03-01

    Optical frequency combs (OFCs) provide a convenient reference for the frequency stabilization of continuous-wave lasers. We demonstrate a frequency control method relying on tracking over a wide range and stabilizing the beat note between the laser and the OFC. The approach combines fast frequency ramps on a millisecond timescale in the entire mode-hop free tuning range of the laser and precise stabilization to single frequencies. We apply it to a commercially available optical parametric oscillator (OPO) and demonstrate tuning over more than 60 GHz with a ramping speed up to 3 GHz/ms. Frequency ramps spanning 15 GHz are performed in less than 10 ms, with the OPO instantly relocked to the OFC after the ramp at any desired frequency. The developed control hardware and software are able to stabilize the OPO to sub-MHz precision and to perform sequences of fast frequency ramps automatically.

  16. Note: Tandem Kirkpatrick-Baez microscope with sixteen channels for high-resolution laser-plasma diagnostics

    NASA Astrophysics Data System (ADS)

    Yi, Shengzhen; Zhang, Zhe; Huang, Qiushi; Zhang, Zhong; Wang, Zhanshan; Wei, Lai; Liu, Dongxiao; Cao, Leifeng; Gu, Yuqiu

    2018-03-01

    Multi-channel Kirkpatrick-Baez (KB) microscopes, which have better resolution and collection efficiency than pinhole cameras, have been widely used in laser inertial confinement fusion to diagnose time evolution of the target implosion. In this study, a tandem multi-channel KB microscope was developed to have sixteen imaging channels with the precise control of spatial resolution and image intervals. This precise control was created using a coarse assembly of mirror pairs with high-accuracy optical prisms, followed by precise adjustment in real-time x-ray imaging experiments. The multilayers coated on the KB mirrors were designed to have substantially the same reflectivity to obtain a uniform brightness of different images for laser-plasma temperature analysis. The study provides a practicable method to achieve the optimum performance of the microscope for future high-resolution applications in inertial confinement fusion experiments.

  17. CONFERENCE NOTE: Conference on Precision Electromagnetic Measurements

    NASA Astrophysics Data System (ADS)

    1991-01-01

    The next Conference on Precision Electromagnetic Measurements (CPEM), will be held from 9 to 12 June 1992 at the Centre des Nouvelles Industries et Technologies (CNIT), La Défense, Paris, France. This conference, which is held every two years and whose importance and high level, confirmed by thirty years' experience, are recognized throughout the world, can be considered as a forum in which scientists, metrologists and professionals will have the opportunity to present and compare their research results on fundamental constants, standards and new techniques of precision measurement in the electromagnetic domain. Topics The following topics are regarded as the most appropriate for this conference: realization of units and fundamental constants d.c. a.c. and high voltage time and frequency radio-frequency and microwaves dielectrics, antennas, fields lasers, fibre optics advanced instrumentation, cryoelectronics. There will also be a session on international cooperation. Conference Language The conference language will be English. No translation will be provided. Organizers Société des Electriciens et des Electroniciens (SEE). Bureau National de Métrologie (BNM) Sponsors Institute of Electrical and Electronics Engineers (IEEE) Instrumentation & Measurement Society Union Radio Scientifique Internationale United States National Institute of Standards and Technology Centre National d'Etudes des Télécommunications Mouvement Français pour la Qualité, Section Métrologie Comité National Français de Radioélectricité Scientifique Contact Jean Zara, CPEM 92 publicity, Bureau National de Métrologie, 22, rue Monge, 75005 Paris Tel.: (33) 1 46 34 48 16, Fax: (33) 1 46 34 48 63

  18. Bilateral coordination and the motor basis of female preference for sexual signals in canary song

    PubMed Central

    Suthers, Roderick A.; Vallet, Eric; Kreutzer, Michel

    2012-01-01

    SUMMARY The preference of female songbirds for particular traits in the songs of courting males has received considerable attention, but the relationship of preferred traits to male quality is poorly understood. Female domestic canaries (Serinus canaria, Linnaeus) preferentially solicit copulation with males that sing special high repetition rate, wide-band, multi-note syllables, called ‘sexy’ or A-syllables. Syllables are separated by minibreaths but each note is produced by pulsatile expiration, allowing high repetition rates and long duration phrases. The wide bandwidth is achieved by including two notes produced sequentially on opposite sides of the syrinx, in which the left and right sides are specialized for low or high frequencies, respectively. The emphasis of low frequencies is facilitated by a positive relationship between syllable repetition rate and the bandwidth of the fundamental frequency of notes sung by the left syrinx, such that bandwidth increases with increasing syllable repetition rate. The temporal offset between notes prevents cheating by unilaterally singing a note on the left side with a low fundamental frequency and prominent higher harmonics. The syringeal and respiratory motor patterns by which sexy syllables are produced support the hypothesis that these syllables provide a sensitive vocal–auditory indicator of a male's performance limit for the rapid, precisely coordinated interhemispheric switching, which is essential for many sensory and motor processes involving specialized contributions from each cerebral hemisphere. PMID:22875764

  19. School Desegregation as an Instrument of Social Policy: Notes Toward a Sociology of the Sociology of Education.

    ERIC Educational Resources Information Center

    Mornell, Eugene S.

    Pointing out that education is clearly one of society's most basic instruments for achieving social conformity, and socialization in the schools is clearly designed to perpetuate the dominant values of the present social system, the author asks whether it does not seem reasonable that those who most precisely articulate these dominant values are…

  20. Humane Letters: Notes on the Concept of Integrity and the Meanings of Humanism

    ERIC Educational Resources Information Center

    Higgins, Chris

    2009-01-01

    In this article, the author calls for an analysis of integrity and contends that attempting to describe wholeness precisely and incisively is not necessarily a contradiction in terms. The author makes some distinctions about integrity using two moves, one inspired by Plato, and one by Aristotle. The author uses the phrase "humane letters" to name…

  1. The Impact of Novice Counselors' Note-Taking Behavior on Recall and Judgment

    ERIC Educational Resources Information Center

    Lo, Chu-Ling; Wadsworth, John

    2014-01-01

    Purpose: To examine the effect of note-taking on novice counselors' recall and judgment of interview information in four situations: no notes, taking notes, taking notes and reviewing these notes, and reviewing notes taken by others. Method: The sample included 13 counselors-in-training recruited from a master's level training program in…

  2. Note: A three-dimensional calibration device for the confocal microscope.

    PubMed

    Jensen, K E; Weitz, D A; Spaepen, F

    2013-01-01

    Modern confocal microscopes enable high-precision measurement in three dimensions by collecting stacks of 2D (x-y) images that can be assembled digitally into a 3D image. It is difficult, however, to ensure position accuracy, particularly along the optical (z) axis where scanning is performed by a different physical mechanism than in x-y. We describe a simple device to calibrate simultaneously the x, y, and z pixel-to-micrometer conversion factors for a confocal microscope. By taking a known 2D pattern and positioning it at a precise angle with respect to the microscope axes, we created a 3D reference standard. The device is straightforward to construct and easy to use.

  3. A simple integrated system for electrophysiologic recordings in animals

    PubMed Central

    Slater, Bernard J.; Miller, Neil R.; Bernstein, Steven L.; Flower, Robert W.

    2009-01-01

    This technical note describes a modification to a fundus camera that permits simultaneous recording of pattern electroretinograms (pERGs) and pattern visual evoked potentials (pVEPs). The modification consists of placing an organic light-emitting diode (OLED) in the split-viewer pathway of a fundus camera, in a plane conjugate to the subject’s pupil. In this way, a focused image of the OLED can be delivered to a precisely known location on the retina. The advantage of using an OLED is that it can achieve high luminance while maintaining high contrast, and with minimal degradation over time. This system is particularly useful for animal studies, especially when precise retinal positioning is required. PMID:19137347

  4. Experience with Geared Propeller Drives for Aviation Engines

    NASA Technical Reports Server (NTRS)

    Kutzbach, K

    1920-01-01

    I. The development of the gear wheels: (a) bending stresses; (b) compressive stresses; (c) heating; (d) precision of manufacture. II. General arrangement of the gearing. III. Vibration in the shaft transmission. An overview is given of experience with geared propeller drives for aviation engines. The development of gear wheels is discussed with emphasis upon bending stresses, compressive stresses, heating, and precision in manufacturing. With respect to the general arrangement of gear drives for airplanes, some principal rules of mechanical engineering that apply with special force are noted. The primary vibrations in the shaft transmission are discussed. With respect to vibration, various methods for computing vibration frequency and the influence of elastic couplings are discussed.

  5. New methods of magnet-based instrumentation for NOTES.

    PubMed

    Magdeburg, Richard; Hauth, Daniel; Kaehler, Georg

    2013-12-01

    Laparoscopic surgery has displaced open surgery as the standard of care for many clinical conditions. NOTES has been described as the next surgical frontier with the objective of incision-free abdominal surgery. The principal challenge of NOTES procedures is the loss of triangulation and instrument rigidity, which is one of the fundamental concepts of laparoscopic surgery. To overcome these problems necessitates the development of new instrumentation. material and methods: We aimed to assess the use of a very simple combination of internal and external magnets that might allow the vigorous multiaxial traction/counter-traction required in NOTES procedures. The magnet retraction system consisted of an external magnetic assembly and either small internal magnets attached by endoscopic clips to the designated tissue (magnet-clip-approach) or an endoscopic grasping forceps in a magnetic deflector roll (magnet-trocar-approach). We compared both methods regarding precision, time and efficacy by performing transgastric partial uterus resections with better results for the magnet-trocar-approach. This proof-of-principle animal study showed that the combination of external and internal magnets generates sufficient coupling forces at clinically relevant abdominal wall thicknesses, making them suitable for use and evaluation in NOTES procedures, and provides the vigorous multiaxial traction/counter-traction required by the lack of additional abdominal trocars.

  6. Development of the functional simulator for the Galileo attitude and articulation control system

    NASA Technical Reports Server (NTRS)

    Namiri, M. K.

    1983-01-01

    A simulation program for verifying and checking the performance of the Galileo Spacecraft's Attitude and Articulation Control Subsystem's (AACS) flight software is discussed. The program, which is called Functional Simulator (FUNSIM), provides a simple method of interfacing user-supplied mathematical models coded in FORTRAN which describes spacecraft dynamics, sensors, and actuators; this is done with the AACS flight software, coded in HAL/S (High-level Advanced Language/Shuttle). It is thus able to simulate the AACS flight software accurately to the HAL/S statement level in the environment of a mainframe computer system. FUNSIM also has a command and data subsystem (CDS) simulator. It is noted that the input/output data and timing are simulated with the same precision as the flight microprocessor. FUNSIM uses a variable stepsize numerical integration algorithm complete with individual error bound control on the state variable to solve the equations of motion. The program has been designed to provide both line printer and matrix dot plotting of the variables requested in the run section and to provide error diagnostics.

  7. An Industry Viewpoint on Electron Energy Distribution Function Control

    NASA Astrophysics Data System (ADS)

    Ventzek, Peter

    2011-10-01

    It is trite to note that plasmas play a key role in industrial technology. Lighting, laser, film coating and now medical technology require plasma science for their sustenance. One field stands out by virtue of its economic girth and impact. Semiconductor manufacturing and process science enabling its decades of innovation owe significant debt to progress in low temperature plasma science. Today, technology requires atomic level control from plasmas. Mere layers of atoms delineate good and bad device performance. While plasma sources meet nanoscale specifications over 100s cm scale dimensions, achieving atomic level control from plasmas is hindered by the absence of direct control of species velocity distribution functions. EEDF control translates to precise control of species flux and velocities at surfaces adjacent to the plasma. Electron energy distribution function (eedf) control is a challenge that, if successfully met, will have a huge impact on nanoscale device manufacturing. This lunchtime talk will attempt to provide context to the research advances presented at this Workshop. Touched on will be areas of new opportunity and the risks associated with missing these opportunities.

  8. A 2-microm continuous-wave laser system for safe and high-precision dissection during NOTES procedures.

    PubMed

    Dray, Xavier; Donatelli, Gianfranco; Krishnamurty, Devi Mukkai; Dubcenco, Elena; Wroblewski, Ronald J; Assumpcao, Lia; Giday, Samuel A; Buscaglia, Jonathan M; Shin, Eun J; Magno, Priscilla; Pipitone, Laurie J; Marohn, Michael R; Kantsevoy, Sergey V; Kalloo, Anthony N

    2010-09-01

    Lasers 2-microm in wavelength offer efficient tissue cutting with limited thermal damage in biological tissue. To evaluate the dissection capabilities of a 2-microm continuous-wave laser for NOTES procedures. We conducted 18 acute animal experiments. Group 1 (three animals): transcolonic access to the peritoneal cavity (15-W transcolonic laser puncture, balloon dilation over the laser probe). Group 2 (six animals): transcolonic access with needle-knife puncture and balloon dilation. Group 3 (three animals): transgastric access to the peritoneal cavity (similar technique as group 1) followed by laser-assisted dissection of the kidney. In one animal of group 3, a therapeutic target (hematoma) was created by percutaneous puncture of the kidney. Group 4 (six animals): transgastric access (similar to the technique of group 2). Translumenal access to the peritoneal cavity was achieved in 2-3 min in group 1 (significantly shorter than with the needle-knife-assisted technique, 4-5 min, p=0.02) and in 7-10 min in group 3 (compared to 6-17 min in group 4, p=0.88). In group 3, laser dissection of the parietal peritoneum and of perinephric connective tissue allowed access to the retroperitoneum with complete removal of a blood collection in the animal with puncture trauma. Laser dissection demonstrated good maneuverability, clean and rapid cutting, and excellent hemostasis. Peritoneoscopy and necropsy showed no damage of targeted tissue and surrounding organs. The 2-microm continuous-wave laser system showed promising capabilities for highly precise and safe dissection during NOTES procedures.

  9. Forming mandrels for making lightweight x-ray mirrors

    NASA Astrophysics Data System (ADS)

    Blake, Peter N.; Saha, Timo; Zhang, William W.; O'Dell, Stephen; Kester, Thomas; Jones, William

    2011-09-01

    Future x-ray astronomical missions, similar to the proposed International X-ray Observatory (IXO), will utilize replicated mirrors to reduce both mass and production costs. Accurately figured and measured molds (called mandrels) - on which the mirror substrates are thermally formed, replicating the surface of the mandrels - are essential to enable these missions. The Optics Branches of the Goddard Space Flight Center (GSFC) and Marshall Space Flight Center (MSFC) have developed fabrication processes along with metrologies that yield high-precision mandrels; and through the SBIR program, they encourage small businesses to attack parts of the remaining problems. The Goddard full-aperture mandrel polisher (the MPM-500) has been developed to a level where mandrel surfaces match the 1.5 arcsec HPD level allocation in a 5 arcsec telescope program. This paper reviews this current technology and describes a pilot program to design a suite of machine tools and process parameters capable of producing many hundreds of these precision objects. A major challenge is to keep mid-spatial frequency errors below 2 nm rms - a severe specification; but we must also note the factors which work to our advantage: e.g., how the figure departs from a pure cone by only one micron, and how the demanding figure specifications which apply in the axial direction are relaxed by an order of magnitude in the azimuthal. Careful study of other large optical fabrication programs in the light of these challenges and advantages has yielded a realistic plan for the economical production of mandrels that meet program requirements in both surface and quantity.

  10. Sex differences in accuracy and precision when judging time to arrival: data from two Internet studies.

    PubMed

    Sanders, Geoff; Sinclair, Kamila

    2011-12-01

    We report two Internet studies that investigated sex differences in the accuracy and precision of judging time to arrival. We used accuracy to mean the ability to match the actual time to arrival and precision to mean the consistency with which each participant made their judgments. Our task was presented as a computer game in which a toy UFO moved obliquely towards the participant through a virtual three-dimensional space on route to a docking station. The UFO disappeared before docking and participants pressed their space bar at the precise moment they thought the UFO would have docked. Study 1 showed it was possible to conduct quantitative studies of spatiotemporal judgments in virtual reality via the Internet and confirmed reports that men are more accurate because women underestimate, but found no difference in precision measured as intra-participant variation. Study 2 repeated Study 1 with five additional presentations of one condition to provide a better measure of precision. Again, men were more accurate than women but there were no sex differences in precision. However, within the coincidence-anticipation timing (CAT) literature, of those studies that report sex differences, a majority found that males are both more accurate and more precise than females. Noting that many CAT studies report no sex differences, we discuss appropriate interpretations of such null findings. While acknowledging that CAT performance may be influenced by experience we suggest that the sex difference may have originated among our ancestors with the evolutionary selection of men for hunting and women for gathering.

  11. Your Criminal Fico Score

    DTIC Science & Technology

    2016-09-01

    about people, especially information collected from documents like case notes (not all law enforcement officers have easy-to-read handwriting ). As...the precision of say , the supercomputer in Willy Wonka and the Chocolate Factory, which could tell the exact location of the golden tickets.93 Rather...various documents, including any bad handwriting , in order to convert the data into the standardized numerical codes needed for the analytic process to

  12. Open Globe Injury Patient Identification in Warfare Clinical Notes1

    PubMed Central

    Apostolova, Emilia; White, Helen A.; Morris, Patty A.; Eliason, David A.; Velez, Tom

    2017-01-01

    The aim of this study is to utilize the Defense and Veterans Eye Injury and Vision Registry clinical data derived from DoD and VA medical systems which include documentation of care while in combat, and develop methods for comprehensive and reliable Open Globe Injury (OGI) patient identification. In particular, we focus on the use of free-form clinical notes, since structured data, such as diagnoses or procedure codes, as found in early post-trauma clinical records, may not be a comprehensive and reliable indicator of OGIs. The challenges of the task include low incidence rate (few positive examples), idiosyncratic military ophthalmology vocabulary, extreme brevity of notes, specialized abbreviations, typos and misspellings. We modeled the problem as a text classification task and utilized a combination of supervised learning (SVMs) and word embeddings learnt in a unsupervised manner, achieving a precision of 92.50% and a recall of89.83%o. The described techniques are applicable to patient cohort identification with limited training data and low incidence rate. PMID:29854104

  13. Study of nanometer-level precise phase-shift system used in electronic speckle shearography and phase-shift pattern interferometry

    NASA Astrophysics Data System (ADS)

    Jing, Chao; Liu, Zhongling; Zhou, Ge; Zhang, Yimo

    2011-11-01

    The nanometer-level precise phase-shift system is designed to realize the phase-shift interferometry in electronic speckle shearography pattern interferometry. The PZT is used as driving component of phase-shift system and translation component of flexure hinge is developed to realize micro displacement of non-friction and non-clearance. Closed-loop control system is designed for high-precision micro displacement, in which embedded digital control system is developed for completing control algorithm and capacitive sensor is used as feedback part for measuring micro displacement in real time. Dynamic model and control model of the nanometer-level precise phase-shift system is analyzed, and high-precision micro displacement is realized with digital PID control algorithm on this basis. It is proved with experiments that the location precision of the precise phase-shift system to step signal of displacement is less than 2nm and the location precision to continuous signal of displacement is less than 5nm, which is satisfied with the request of the electronic speckle shearography and phase-shift pattern interferometry. The stripe images of four-step phase-shift interferometry and the final phase distributed image correlated with distortion of objects are listed in this paper to prove the validity of nanometer-level precise phase-shift system.

  14. Poor neuro-motor tuning of the human larynx: a comparison of sung and whistled pitch imitation

    PubMed Central

    Johnson, Joseph F.; Kotz, Sonja A.

    2018-01-01

    Vocal imitation is a hallmark of human communication that underlies the capacity to learn to speak and sing. Even so, poor vocal imitation abilities are surprisingly common in the general population and even expert vocalists cannot match the precision of a musical instrument. Although humans have evolved a greater degree of control over the laryngeal muscles that govern voice production, this ability may be underdeveloped compared with control over the articulatory muscles, such as the tongue and lips, volitional control of which emerged earlier in primate evolution. Human participants imitated simple melodies by either singing (i.e. producing pitch with the larynx) or whistling (i.e. producing pitch with the lips and tongue). Sung notes were systematically biased towards each individual's habitual pitch, which we hypothesize may act to conserve muscular effort. Furthermore, while participants who sung more precisely also whistled more precisely, sung imitations were less precise than whistled imitations. The laryngeal muscles that control voice production are under less precise control than the oral muscles that are involved in whistling. This imprecision may be due to the relatively recent evolution of volitional laryngeal-motor control in humans, which may be tuned just well enough for the coarse modulation of vocal-pitch in speech. PMID:29765635

  15. Notes From the Field: Secondary Task Precision for Cognitive Load Estimation During Virtual Reality Surgical Simulation Training.

    PubMed

    Rasmussen, Sebastian R; Konge, Lars; Mikkelsen, Peter T; Sørensen, Mads S; Andersen, Steven A W

    2016-03-01

    Cognitive load (CL) theory suggests that working memory can be overloaded in complex learning tasks such as surgical technical skills training, which can impair learning. Valid and feasible methods for estimating the CL in specific learning contexts are necessary before the efficacy of CL-lowering instructional interventions can be established. This study aims to explore secondary task precision for the estimation of CL in virtual reality (VR) surgical simulation and also investigate the effects of CL-modifying factors such as simulator-integrated tutoring and repeated practice. Twenty-four participants were randomized for visual assistance by a simulator-integrated tutor function during the first 5 of 12 repeated mastoidectomy procedures on a VR temporal bone simulator. Secondary task precision was found to be significantly lower during simulation compared with nonsimulation baseline, p < .001. Contrary to expectations, simulator-integrated tutoring and repeated practice did not have an impact on secondary task precision. This finding suggests that even though considerable changes in CL are reflected in secondary task precision, it lacks sensitivity. In contrast, secondary task reaction time could be more sensitive, but requires substantial postprocessing of data. Therefore, future studies on the effect of CL modifying interventions should weigh the pros and cons of the various secondary task measurements. © The Author(s) 2015.

  16. Automatically Detecting Likely Edits in Clinical Notes Created Using Automatic Speech Recognition

    PubMed Central

    Lybarger, Kevin; Ostendorf, Mari; Yetisgen, Meliha

    2017-01-01

    The use of automatic speech recognition (ASR) to create clinical notes has the potential to reduce costs associated with note creation for electronic medical records, but at current system accuracy levels, post-editing by practitioners is needed to ensure note quality. Aiming to reduce the time required to edit ASR transcripts, this paper investigates novel methods for automatic detection of edit regions within the transcripts, including both putative ASR errors but also regions that are targets for cleanup or rephrasing. We create detection models using logistic regression and conditional random field models, exploring a variety of text-based features that consider the structure of clinical notes and exploit the medical context. Different medical text resources are used to improve feature extraction. Experimental results on a large corpus of practitioner-edited clinical notes show that 67% of sentence-level edits and 45% of word-level edits can be detected with a false detection rate of 15%. PMID:29854187

  17. Project Notes

    ERIC Educational Resources Information Center

    School Science Review, 1978

    1978-01-01

    Presents sixteen project notes developed by pupils of Chipping Norton School and Bristol Grammar School, in the United Kingdom. These Projects include eight biology A-level projects and eight Chemistry A-level projects. (HM)

  18. The International College of Neuro-Psychopharmacology (CINP) Treatment Guidelines for Bipolar Disorder in Adults (CINP-BD-2017), Part 2: Review, Grading of the Evidence, and a Precise Algorithm

    PubMed Central

    Yatham, Lakshmi; Grunze, Heinz; Vieta, Eduard; Young, Allan; Blier, Pierre; Kasper, Siegfried; Moeller, Hans Jurgen

    2017-01-01

    Abstract Background: The current paper includes a systematic search of the literature, a detailed presentation of the results, and a grading of treatment options in terms of efficacy and tolerability/safety. Material and Methods: The PRISMA method was used in the literature search with the combination of the words ‘bipolar,’ ‘manic,’ ‘mania,’ ‘manic depression,’ and ‘manic depressive’ with ‘randomized,’ and ‘algorithms’ with ‘mania,’ ‘manic,’ ‘bipolar,’ ‘manic-depressive,’ or ‘manic depression.’ Relevant web pages and review articles were also reviewed. Results: The current report is based on the analysis of 57 guideline papers and 531 published papers related to RCTs, reviews, posthoc, or meta-analysis papers to March 25, 2016. The specific treatment options for acute mania, mixed episodes, acute bipolar depression, maintenance phase, psychotic and mixed features, anxiety, and rapid cycling were evaluated with regards to efficacy. Existing treatment guidelines were also reviewed. Finally, Tables reflecting efficacy and recommendation levels were created that led to the development of a precise algorithm that still has to prove its feasibility in everyday clinical practice. Conclusions: A systematic literature search was conducted on the pharmacological treatment of bipolar disorder to identify all relevant random controlled trials pertaining to all aspects of bipolar disorder and graded the data according to a predetermined method to develop a precise treatment algorithm for management of various phases of bipolar disorder. It is important to note that the some of the recommendations in the treatment algorithm were based on the secondary outcome data from posthoc analyses. PMID:27816941

  19. Glucose metabolism disorder in obese children assessed by continuous glucose monitoring system.

    PubMed

    Zou, Chao-Chun; Liang, Li; Hong, Fang; Zhao, Zheng-Yan

    2008-02-01

    Continuous glucose monitoring system (CGMS) can measure glucose levels at 5-minute intervals over a few days, and may be used to detect hypoglycemia, guide insulin therapy, and control glucose levels. This study was undertaken to assess the glucose metabolism disorder by CGMS in obese children. Eighty-four obese children were studied. Interstitial fluid (ISF) glucose levels were measured by CGMS for 24 hours covering the time for oral glucose tolerance test (OGTT). Impaired glucose tolerance (IGT), impaired fasting glucose (IFG), type 2 diabetic mellitus (T2DM) and hypoglycemia were assessed by CGMS. Five children failed to complete CGMS test. The glucose levels in ISF measured by CGMS were highly correlated with those in capillary samples (r=0.775, P<0.001). However, the correlation between ISF and capillary glucose levels was lower during the first hour than that in the later time period (r=0.722 vs r=0.830), and the ISF glucose levels in 69.62% of children were higher than baseline levels in the initial 1-3 hours. In 79 obese children who finished the CGMS, 2 children had IFG, 2 had IGT, 3 had IFG + IGT, and 2 had T2DM. Nocturnal hypoglycemia was noted during the overnight fasting in 11 children (13.92%). Our data suggest that glucose metabolism disorder including hyperglycemia and hypoglycemia is very common in obese children. Further studies are required to improve the precision of the CGMS in children.

  20. Direct phase-locking of a 8.6-μm quantum cascade laser to a mid-IR optical frequency comb: application to precision spectroscopy of N2O.

    PubMed

    Gambetta, Alessio; Cassinerio, Marco; Coluccelli, Nicola; Fasci, Eugenio; Castrillo, Antonio; Gianfrani, Livio; Gatti, Davide; Marangoni, Marco; Laporta, Paolo; Galzerano, Gianluca

    2015-02-01

    We developed a high-precision spectroscopic system at 8.6 μm based on direct heterodyne detection and phase-locking of a room-temperature quantum-cascade-laser against an harmonic, 250-MHz mid-IR frequency comb obtained by difference-frequency generation. The ∼30  dB signal-to-noise ratio of the detected beat-note together with the achieved closed-loop locking bandwidth of ∼500  kHz allows for a residual integrated phase noise of 0.78 rad (1 Hz-5 MHz), for an ultimate resolution of ∼21  kHz, limited by the measured linewidth of the mid-IR comb. The system was used to perform absolute measurement of line-center frequencies for the rotational components of the ν2 vibrational band of N2O, with a relative precision of 3×10(-10).

  1. Causal Video Object Segmentation From Persistence of Occlusions

    DTIC Science & Technology

    2015-05-01

    Precision, recall, and F-measure are reported on the ground truth anno - tations converted to binary masks. Note we cannot evaluate “number of...to lack of occlusions. References [1] P. Arbelaez, M. Maire, C. Fowlkes, and J . Malik. Con- tour detection and hierarchical image segmentation. TPAMI...X. Bai, J . Wang, D. Simons, and G. Sapiro. Video snapcut: robust video object cutout using localized classifiers. In ACM Transactions on Graphics

  2. European Science Notes Information Bulletin Reports on Current European/ Middle Eastern Science

    DTIC Science & Technology

    1988-07-01

    41 Recently concluded and planned experiments are described which arc based on static Kerr effect dis- persion- spectroscopy , optical Kerr effect...studies, and both electric and magnetic resonance 6 molecular beam spectroscopy . These advanced techniques are used to measure with great precision...simuhItio , using thrcc-dimcn- flight using temperature-sensitive films and infrared sional singularities in a panel ncthod. camecras placed on either side

  3. USSR Report, International Affairs.

    DTIC Science & Technology

    1986-04-16

    ultra-leftists and to achieve a notable success in the elections. As General Secretary of the Communist Party Central Committee Gilberto Vieira noted...8217"] [Text] ...In March Amilcar Freire , who worked under contract as an accountant for the British Africa Textile factory in the city of Benguela...years earlier, when Angola was still a Portuguese colony, Freire had made a tourist trip around South Africa or, more precisely, its "white zones." He

  4. An evaluation of portion size estimation aids: precision, ease of use and likelihood of future use.

    PubMed

    Faulkner, Gemma P; Livingstone, M Barbara E; Pourshahidi, L Kirsty; Spence, Michelle; Dean, Moira; O'Brien, Sinead; Gibney, Eileen R; Wallace, Julie Mw; McCaffrey, Tracy A; Kerr, Maeve A

    2016-09-01

    The present study aimed to evaluate the precision, ease of use and likelihood of future use of portion size estimation aids (PSEA). A range of PSEA were used to estimate the serving sizes of a range of commonly eaten foods and rated for ease of use and likelihood of future usage. For each food, participants selected their preferred PSEA from a range of options including: quantities and measures; reference objects; measuring; and indicators on food packets. These PSEA were used to serve out various foods (e.g. liquid, amorphous, and composite dishes). Ease of use and likelihood of future use were noted. The foods were weighed to determine the precision of each PSEA. Males and females aged 18-64 years (n 120). The quantities and measures were the most precise PSEA (lowest range of weights for estimated portion sizes). However, participants preferred household measures (e.g. 200 ml disposable cup) - deemed easy to use (median rating of 5), likely to use again in future (all scored either 4 or 5 on a scale from 1='not very likely' to 5='very likely to use again') and precise (narrow range of weights for estimated portion sizes). The majority indicated they would most likely use the PSEA preparing a meal (94 %), particularly dinner (86 %) in the home (89 %; all P<0·001) for amorphous grain foods. Household measures may be precise, easy to use and acceptable aids for estimating the appropriate portion size of amorphous grain foods.

  5. Differential Effects of Full and Partial Notes on Learning Outcomes and Attendance

    ERIC Educational Resources Information Center

    Cornelius, Tara L.; Owen-DeSchryver, Jamie

    2008-01-01

    Although college instructors are increasingly providing students with online notes, research is equivocal on how such notes affect student outcomes. This study examined partial versus full notes in introductory psychology classes while controlling for initial levels of student knowledge and academic ability. Results suggested that students…

  6. Positive Effects of Restricting Student Note-Taking in a Capstone Psychology Course: Reducing the Demands of Divided Attention in the Classroom

    ERIC Educational Resources Information Center

    Long, Gerald M.

    2014-01-01

    Two versions of a senior-level capstone course with differing note-taking strategies were compared. In one semester, a traditional student note-taking format was used; in another semester, student note-taking was rendered unnecessary by providing students with complete instructor notes. Student performance in the course as well as student opinions…

  7. Design of automatic leveling and centering system of theodolite

    NASA Astrophysics Data System (ADS)

    Liu, Chun-tong; He, Zhen-Xin; Huang, Xian-xiang; Zhan, Ying

    2012-09-01

    To realize the theodolite automation and improve the azimuth Angle measurement instrument, the theodolite automatic leveling and centering system with the function of leveling error compensation is designed, which includes the system solution, key components selection, the mechanical structure of leveling and centering, and system software solution. The redesigned leveling feet are driven by the DC servo motor; and the electronic control center device is installed. Using high precision of tilt sensors as horizontal skew detection sensors ensures the effectiveness of the leveling error compensation. Aiming round mark center is located using digital image processing through surface array CCD; and leveling measurement precision can reach the pixel level, which makes the theodolite accurate centering possible. Finally, experiments are conducted using the automatic leveling and centering system of the theodolite. The results show the leveling and centering system can realize automatic operation with high centering accuracy of 0.04mm.The measurement precision of the orientation angle after leveling error compensation is improved, compared with that of in the traditional method. Automatic leveling and centering system of theodolite can satisfy the requirements of the measuring precision and its automation.

  8. Precision liquid level sensor

    DOEpatents

    Field, M.E.; Sullivan, W.H.

    A precision liquid level sensor utilizes a balanced bridge, each arm including an air dielectric line. Changes in liquid level along one air dielectric line imbalance the bridge and create a voltage which is directly measurable across the bridge.

  9. Spatial distribution of nymphs of Scaphoideus titanus (Homoptera: Cicadellidae) in grapes, and evaluation of sequential sampling plans.

    PubMed

    Lessio, Federico; Alma, Alberto

    2006-04-01

    The spatial distribution of the nymphs of Scaphoideus titanus Ball (Homoptera Cicadellidae), the vector of grapevine flavescence dorée (Candidatus Phytoplasma vitis, 16Sr-V), was studied by applying Taylor's power law. Studies were conducted from 2002 to 2005, in organic and conventional vineyards of Piedmont, northern Italy. Minimum sample size and fixed precision level stop lines were calculated to develop appropriate sampling plans. Model validation was performed, using independent field data, by means of Resampling Validation of Sample Plans (RVSP) resampling software. The nymphal distribution, analyzed via Taylor's power law, was aggregated, with b = 1.49. A sample of 32 plants was adequate at low pest densities with a precision level of D0 = 0.30; but for a more accurate estimate (D0 = 0.10), the required sample size needs to be 292 plants. Green's fixed precision level stop lines seem to be more suitable for field sampling: RVSP simulations of this sampling plan showed precision levels very close to the desired levels. However, at a prefixed precision level of 0.10, sampling would become too time-consuming, whereas a precision level of 0.25 is easily achievable. How these results could influence the correct application of the compulsory control of S. titanus and Flavescence dorée in Italy is discussed.

  10. What Limits the Encoding Effect of Note-Taking? A Meta-Analytic Examination

    ERIC Educational Resources Information Center

    Kobayashi, K.

    2005-01-01

    Previous meta-analyses indicate that the overall encoding effect of note-taking is positive but modest. This meta-analysis of 57 note-taking versus no note-taking comparison studies explored what limits the encoding effect by examining the moderating influence of seven variables: intervention, schooling level, presentation mode and length, test…

  11. Online Class Size, Note Reading, Note Writing and Collaborative Discourse

    ERIC Educational Resources Information Center

    Qiu, Mingzhu; Hewitt, Jim; Brett, Clare

    2012-01-01

    Researchers have long recognized class size as affecting students' performance in face-to-face contexts. However, few studies have examined the effects of class size on exact reading and writing loads in online graduate-level courses. This mixed-methods study examined relationships among class size, note reading, note writing, and collaborative…

  12. Linewidth and tuning characteristics of terahertz quantum cascade lasers.

    PubMed

    Barkan, A; Tittel, F K; Mittleman, D M; Dengler, R; Siegel, P H; Scalari, G; Ajili, L; Faist, J; Beere, H E; Linfield, E H; Davies, A G; Ritchie, D A

    2004-03-15

    We have measured the spectral linewidths of three continuous-wave quantum cascade lasers operating at terahertz frequencies by heterodyning the free-running quantum cascade laser with two far-infrared gas lasers. Beat notes are detected with a GaAs diode mixer and a microwave spectrum analyzer, permitting very precise frequency measurements and giving instantaneous linewidths of less than -30 kHz. Characteristics are also reported for frequency tuning as the injection current is varied.

  13. C-5M Super Galaxy Utilization with Joint Precision Airdrop System

    DTIC Science & Technology

    2012-03-22

    System Notes FireFly 900-2,200 Steerable Parafoil Screamer 500-2,200 Steerable Parafoil w/additional chutes to slow touchdown Dragonfly...setting . This initial feasible solution provides the Nonlinear Program algorithm a starting point to continue its calculations. The model continues...provides the NLP with a starting point of 1. This provides the NLP algorithm a point within the feasible region to begin its calculations in an attempt

  14. Trichloroethylene and stoddard solvent reduction alternatives in a small shop. 1989 summer intern report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Taylor, D.J.

    1989-12-31

    Aero Precision Engineering Corp. is a small screw machine shop which produces precision parts for industry located in St. Paul Park, MN. The project focused on identifying satisfactory water-based substitutes for trichloroethylene (TCE) used both as a vapor degreaser and as a cold solvent in a small covered container. At the time of the project, the company used about 500 gallons of trichloroethylene with approximately 165 gallons shipped off site as waste annually. The solvent was used primarily to remove cutting oil and metal chips from production parts. In identifying a standard for evaluating alterantives to the solvent for cleaning,more » it was noted that parts cleaned in the cold bucket were definitely not as clean as those cleaned in the vapor degreaser.« less

  15. Precision liquid level sensor

    DOEpatents

    Field, Michael E.; Sullivan, William H.

    1985-01-01

    A precision liquid level sensor utilizes a balanced R. F. bridge, each arm including an air dielectric line. Changes in liquid level along one air dielectric line imbalance the bridge and create a voltage which is directly measurable across the bridge.

  16. Precision liquid level sensor

    DOEpatents

    Field, M.E.; Sullivan, W.H.

    1985-01-29

    A precision liquid level sensor utilizes a balanced R. F. bridge, each arm including an air dielectric line. Changes in liquid level along one air dielectric line imbalance the bridge and create a voltage which is directly measurable across the bridge. 2 figs.

  17. Biology Notes.

    ERIC Educational Resources Information Center

    School Science Review, 1984

    1984-01-01

    Presents information on the teaching of nutrition (including new information relating to many current O-level syllabi) and part 16 of a reading list for A- and S-level biology. Also includes a note on using earthworms as a source of material for teaching meiosis. (JN)

  18. Digital approach to stabilizing optical frequency combs and beat notes of CW lasers

    NASA Astrophysics Data System (ADS)

    Čížek, Martin; Číp, Ondřej; Å míd, Radek; Hrabina, Jan; Mikel, Břetislav; Lazar, Josef

    2013-10-01

    In cases when it is necessary to lock optical frequencies generated by an optical frequency comb to a precise radio frequency (RF) standard (GPS-disciplined oscillator, H-maser, etc.) the usual practice is to implement phase and frequency-locked loops. Such system takes the signal generated by the RF standard (usually 10 MHz or 100 MHz) as a reference and stabilizes the repetition and offset frequencies of the comb contained in the RF output of the f-2f interferometer. These control loops are usually built around analog electronic circuits processing the output signals from photo detectors. This results in transferring the stability of the standard from RF to optical frequency domain. The presented work describes a different approach based on digital signal processing and software-defined radio algorithms used for processing the f-2f and beat-note signals. Several applications of digital phase and frequency locks to a RF standard are demonstrated: the repetition (frep) and offset frequency (fceo) of the comb, and the frequency of the beat note between a CW laser source and a single component of the optical frequency comb spectrum.

  19. SUPPLEMENTARY COMPARISON: Report of the bilateral comparison of the calibrations of hydrometers for liquid density determination between CENAM-Mexico and INRIM-Italy: SIM.M.D-S1

    NASA Astrophysics Data System (ADS)

    Becerra, Luis Omar; Lorefice, Salvatore

    2009-01-01

    Hydrometers are instruments usually made of glass which are widely used for different levels of precision to measure liquid density and related quantities to control different products and processes. This bilateral comparison on the calibration of hydrometers shows that results reported by CENAM-Mexico and INRIM-Italy are consistent within the claimed uncertainty in the range of 800 kg/m3 to 1200 kg/m3. This bilateral comparison is intended to link the two regional comparisons SIM.M.D-K4 and EURAMET.D-K4. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by SIM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  20. A brief note on the magnecule order parameter upgrade hypothesis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schmidt, Nathan O.

    2015-03-10

    In this short remark, we report on recent hypothetical work that aims to equip Santilli’s magnecule model with topological deformation order parameters (OP) of fractional statistics to define a preliminary set of wavepacket wavefunctions for the electron toroidal polarizations. The primary objective is to increase the representational precision and predictive accuracy of the magnecule model by exemplifying the fluidic characteristics for direct industrial application. In particular, the OPs are deployed to encode the spontaneous superfluidic gauge symmetry breaking (which may be restored at the iso-topic level) and correlated with Leggett’s superfluid B phases to establish a long range constraint formore » the wavefunctions. These new, developing, theoretical results may be significant because the OP configuration arms us with an extra degree of freedom for encoding a magnecule’s states and transitions, which may reveal further insight into the underlying physical mechanisms and features associated with these state-of-the-art magnecular bonds.« less

  1. Multiresolution texture analysis applied to road surface inspection

    NASA Astrophysics Data System (ADS)

    Paquis, Stephane; Legeay, Vincent; Konik, Hubert; Charrier, Jean

    1999-03-01

    Technological advances provide now the opportunity to automate the pavement distress assessment. This paper deals with an approach for achieving an automatic vision system for road surface classification. Road surfaces are composed of aggregates, which have a particular grain size distribution and a mortar matrix. From various physical properties and visual aspects, four road families are generated. We present here a tool using a pyramidal process with the assumption that regions or objects in an image rise up because of their uniform texture. Note that the aim is not to compute another statistical parameter but to include usual criteria in our method. In fact, the road surface classification uses a multiresolution cooccurrence matrix and a hierarchical process through an original intensity pyramid, where a father pixel takes the minimum gray level value of its directly linked children pixels. More precisely, only matrix diagonal is taken into account and analyzed along the pyramidal structure, which allows the classification to be made.

  2. The precision seismometer based on planar electrochemical transducer

    NASA Astrophysics Data System (ADS)

    Shabalina, A. S.; Krishtop, V. G.

    2016-12-01

    In this paper we investigate the possibility of applying a planar electrochemical trancducer (ECT) as a sensing element for a precision seismometer with a high inertial mass. The precision seismometer based on simplest planar ECT was manufactured and tested. We investigated the amplitude-frequency and volt-ampere characteristics, self-noise level and the transducer's impedance frequency dependence. One of the key characteristics for the seismometer is the intrinsic noise level, this work focuses on the self-noise level.

  3. Systemic Inflammatory Response After Natural Orifice Translumenal Surgery: Transvaginal Cholecystectomy in a Porcine Model

    PubMed Central

    Fan, Joe K. M.; Tong, Daniel K. H.; HO, David W. Y.; Luk, John; Law, Simon

    2009-01-01

    Objective: We analyzed circulating TNF-α and IL-6 to determine systemic inflammatory responses associated with transvaginal cholecystectomy in a porcine model. Methods: Six female pigs were used for a survival study after transvaginal cholecystectomy (NOTES group) using endoscopic submucosal dissection (ESD) instruments and a single-channel endoscope. Blood was drawn preoperatively and 24 hours and 48 hours postoperatively. Four pigs were used as controls. In addition, laparoscopic cholecystectomy was performed in 2 pigs for laparoscopic control. Results: In all 6 pigs in the NOTES group, no major intraoperative complications occurred. No significant differences were found between control, laparoscopic, and NOTES groups in terms of preoperative IL-6 level (P=0.897) and at 24 hours (P=0.790), and 48 hours postoperatively (P=0.945). Similarly, there was no significant difference in mean preoperative (P=0.349) and mean day 2 postoperative TNF-α levels (P=0.11). But a significant increase in day 1 postoperative TNF-α levels in the laparoscopic group compared with that in the control and NOTES groups was observed (P=0.049). One limitation of our study is that the sample size was relatively small. Conclusion: NOTES is safe in animal models in terms of anatomical and cellular level changes with minimal systemic inflammatory host responses elicited. Further study needs to be carried out in humans before NOTES can be recommended for routine use. PMID:19366533

  4. Do Resting Plasma β-Endorphin Levels Predict Responses to Opioid Analgesics?

    PubMed

    Bruehl, Stephen; Burns, John W; Gupta, Rajnish; Buvanendran, Asokumar; Chont, Melissa; Orlowska, Daria; Schuster, Erik; France, Christopher R

    2017-01-01

    Clinically feasible predictors of opioid analgesic responses for use in precision pain medicine protocols are needed. This study evaluated whether resting plasma β-endorphin (BE) levels predicted responses to an opioid analgesic, and whether chronic pain status or sex moderated these effects. Participants included 73 individuals with chronic low back pain (CLBP) and 88 pain-free controls, all using no daily opioid analgesics. Participants attended 2 identical laboratory sessions during which they received either intravenous morphine (0.08 mg/kg) or saline placebo, with blood samples obtained before drug administration to assay resting plasma BE levels. Once peak drug activity was achieved in each session, participants engaged in an ischemic forearm pain task (ISC) and a heat pain task. Morphine analgesic effects were derived reflecting the difference in pain outcomes between placebo and morphine conditions. In hierarchical regressions, significant Type (CLBP vs. control)×BE interactions (Ps<0.05) were noted for morphine effects on ISC tolerance, ISC intratask pain ratings, and thermal VAS unpleasantness ratings. These interactions derived primarily from associations between higher BE levels and smaller morphine effects restricted to the CLBP subgroup. All other BE-related effects, including sex interactions, for predicting morphine analgesia failed to reach statistical significance. BE was a predictor of morphine analgesia for only 3 out of 9 outcomes examined, with these effects moderated by chronic pain status but not sex. On the whole, results do not suggest that resting plasma BE levels are likely to be a clinically useful predictor of opioid analgesic responses.

  5. The Common Fund Initiative and Its Implication for Advancing Exercise and Physical Activity Research in Child Health.

    PubMed

    Cooper, Dan M; Radom-Aizik, Shlomit

    2015-08-01

    NIH Director Francis Collins noted that the Common Fund initiative would lead to unprecedented insights into the mechanisms responsible for the health effects of physical activity. He noted: “Armed with this knowledge, researchers and clinicians may one day be able to define optimal physical activity recommendations for people at various stages of life, as well as develop precisely targeted regimens for individuals with particular health needs.” Given the ominous burden of physical inactivity-related diseases and conditions in otherwise healthy children, and the growing number of children who survive chronic diseases in whom we know little about what constitutes healthy exercise, it is essential that the community of child health researchers develop compelling strategies and proposals in response to the unique opportunity offered through the Common Fund mechanism.

  6. Communicating Geographical Risks in Crisis Management: The Need for Research.

    PubMed

    French, Simon; Argyris, Nikolaos; Haywood, Stephanie M; Hort, Matthew C; Smith, Jim Q

    2017-10-23

    In any crisis, there is a great deal of uncertainty, often geographical uncertainty or, more precisely, spatiotemporal uncertainty. Examples include the spread of contamination from an industrial accident, drifting volcanic ash, and the path of a hurricane. Estimating spatiotemporal probabilities is usually a difficult task, but that is not our primary concern. Rather, we ask how analysts can communicate spatiotemporal uncertainty to those handling the crisis. We comment on the somewhat limited literature on the representation of spatial uncertainty on maps. We note that many cognitive issues arise and that the potential for confusion is high. We note that in the early stages of handling a crisis, the uncertainties involved may be deep, i.e., difficult or impossible to quantify in the time available. In such circumstance, we suggest the idea of presenting multiple scenarios. © 2017 Society for Risk Analysis.

  7. "Analytical" vector-functions I

    NASA Astrophysics Data System (ADS)

    Todorov, Vladimir Todorov

    2017-12-01

    In this note we try to give a new (or different) approach to the investigation of analytical vector functions. More precisely a notion of a power xn; n ∈ ℕ+ of a vector x ∈ ℝ3 is introduced which allows to define an "analytical" function f : ℝ3 → ℝ3. Let furthermore f (ξ )= ∑n =0 ∞ anξn be an analytical function of the real variable ξ. Here we replace the power ξn of the number ξ with the power of a vector x ∈ ℝ3 to obtain a vector "power series" f (x )= ∑n =0 ∞ anxn . We research some properties of the vector series as well as some applications of this idea. Note that an "analytical" vector function does not depend of any basis, which may be used in research into some problems in physics.

  8. EMIIM Wetting Properties & Their Effect on Electrospray Thruster Design

    DTIC Science & Technology

    2012-03-01

    tension and contact or “wetting" angle formed when a liquid droplet comes in contact with a solid surface. Ideally this angle is a function of the...3 3 Picture of a Taylor cone formed at AFRL, note bubbles present. . . . . . . 3 4 Titanium electrode grids in use at AFRL...cone formed using an internally wetted emitter and the ionic liquid BMI-BG4 is shown in Figure 3.[7] Emitters are precisely aligned with openings

  9. Evaluating the Advantages and Disadvantages of Providing Lecture Notes: The Role of Internet Technology as a Delivery System and Research Tool

    ERIC Educational Resources Information Center

    Grabe, Mark; Christopherson, Kimberly

    2005-01-01

    Relationships among patterns of access to online notes, examination performance, and student absenteeism were examined. Students who made more frequent use of online notes performed at a higher level on course examinations. Students most frequently accessed online notes while corresponding lecture content was being presented in class, but this…

  10. Guided surgical debridement: staining tissues with methylene blue.

    PubMed

    Dorafshar, Amir H; Gitman, Marina; Henry, Ginard; Agarwal, Shailesh; Gottlieb, Lawrence J

    2010-01-01

    Precise surgical debridement of wounds is required to achieve wound closure. The authors describe their experience with a technique using topical methylene blue to facilitate precise surgical debridement. In this technique, methylene blue dye is applied topically to the wound surface at the onset of surgery. The stained wound site is then wiped to remove dye from the surface of normal epithelium; eschar, nonviable tissue, and granulation tissue remain stained. The methylene blue-stained tissue is surgically removed, and the newly debrided surface of the wound is assessed for adequate vascularity and biopsied to verify presence of bacteriologic balance before closure. The authors have used this technique in more than 200 wound debridements during the past year, including acute surgical or traumatic wounds, acute and subacute burn wounds, chronic granulating wounds, partially epithelialized wounds, sinus tracts, and fistulae. No adverse reactions have been noted, even on patients undergoing multiple applications through serial operations. Topical application of methylene blue to wounds with mixed tissue content helps to distinguish between viable and nonviable tissue and between epithelialized and nonepithelialized areas, facilitating more precise and complete wound debridement.

  11. Islander: A database of precisely mapped genomic islands in tRNA and tmRNA genes

    DOE PAGES

    Hudson, Corey M.; Lau, Britney Y.; Williams, Kelly P.

    2014-11-05

    Genomic islands are mobile DNAs that are major agents of bacterial and archaeal evolution. Integration into prokaryotic chromosomes usually occurs site-specifically at tRNA or tmRNA gene (together, tDNA) targets, catalyzed by tyrosine integrases. This splits the target gene, yet sequences within the island restore the disrupted gene; the regenerated target and its displaced fragment precisely mark the endpoints of the island. We applied this principle to search for islands in genomic DNA sequences. Our algorithm identifies tDNAs, finds fragments of those tDNAs in the same replicon and removes unlikely candidate islands through a series of filters. A search for islandsmore » in 2168 whole prokaryotic genomes produced 3919 candidates. The website Islander (recently moved to http://bioinformatics.sandia.gov/islander/) presents these precisely mapped candidate islands, the gene content and the island sequence. The algorithm further insists that each island encode an integrase, and attachment site sequence identity is carefully noted; therefore, the database also serves in the study of integrase site-specificity and its evolution.« less

  12. 24. Pump Room interiordewatering pump motor on upper level. Note ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    24. Pump Room interior-dewatering pump motor on upper level. Note the removable roof hatch (steel frame) directly above motor. Dewatering pumps motor control center at left - Hunters Point Naval Shipyard, Drydock No. 4, East terminus of Palou Avenue, San Francisco, San Francisco County, CA

  13. Sample size requirements for the design of reliability studies: precision consideration.

    PubMed

    Shieh, Gwowen

    2014-09-01

    In multilevel modeling, the intraclass correlation coefficient based on the one-way random-effects model is routinely employed to measure the reliability or degree of resemblance among group members. To facilitate the advocated practice of reporting confidence intervals in future reliability studies, this article presents exact sample size procedures for precise interval estimation of the intraclass correlation coefficient under various allocation and cost structures. Although the suggested approaches do not admit explicit sample size formulas and require special algorithms for carrying out iterative computations, they are more accurate than the closed-form formulas constructed from large-sample approximations with respect to the expected width and assurance probability criteria. This investigation notes the deficiency of existing methods and expands the sample size methodology for the design of reliability studies that have not previously been discussed in the literature.

  14. Precisely cyclic sand: self-organization of periodically sheared frictional grains.

    PubMed

    Royer, John R; Chaikin, Paul M

    2015-01-06

    The disordered static structure and chaotic dynamics of frictional granular matter has occupied scientists for centuries, yet there are few organizational principles or guiding rules for this highly hysteretic, dissipative material. We show that cyclic shear of a granular material leads to dynamic self-organization into several phases with different spatial and temporal order. Using numerical simulations, we present a phase diagram in strain-friction space that shows chaotic dispersion, crystal formation, vortex patterns, and most unusually a disordered phase in which each particle precisely retraces its unique path. However, the system is not reversible. Rather, the trajectory of each particle, and the entire frictional, many-degrees-of-freedom system, organizes itself into a limit cycle absorbing state. Of particular note is that fact that the cyclic states are spatially disordered, whereas the ordered states are chaotic.

  15. Note: Low phase noise programmable phase-locked loop with high temperature stability.

    PubMed

    Michálek, Vojtěch; Procházka, Ivan

    2017-03-01

    The design and construction of low jitter programmable phase-locked loop with low temperature coefficient of phase are presented. It has been designed for demanding high precision timing applications, especially as a clock source for event timer with subpicosecond precision. The phase-locked loop itself has a jitter of few hundreds of femtoseconds. It produces square wave with programmable output frequency from 100 MHz to 500 MHz and programmable amplitude of 0.25 V to 1.2 V peak-to-peak, which is locked to 5 MHz or 10 MHz reference frequency common for disciplined oscillators and highly stable clocks such as hydrogen maser. Moreover, it comprises an on-board temperature compensated crystal oscillator for stand-alone usage. The device provides temperature coefficient of the phase lock of 0.9 ps/K near room temperature.

  16. Note: Compact and light displacement sensor for a precision measurement system in large motion

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, Sang Heon, E-mail: shlee@andong.ac.kr

    We developed a compact and light displacement sensor applicable to systems that require wide range motions of its sensing device. The proposed sensor utilized the optical pickup unit of the optical disk drive, which has been used applied to atomic force microscopy (AFM) because of its compactness and lightness as well as its high performance. We modified the structure of optical pickup unit and made the compact sensor driver attachable to a probe head of AFM to make large rotation. The feasibilities of the developed sensor for a general probe-moving measurement device and for probe-rotating AFM were verified. Moreover, amore » simple and precise measurement of alignment between centers of rotator and probe tip in probe-rotation AFM was experimentally demonstrated using the developed sensor.« less

  17. Precisely cyclic sand: Self-organization of periodically sheared frictional grains

    PubMed Central

    Royer, John R.; Chaikin, Paul M.

    2015-01-01

    The disordered static structure and chaotic dynamics of frictional granular matter has occupied scientists for centuries, yet there are few organizational principles or guiding rules for this highly hysteretic, dissipative material. We show that cyclic shear of a granular material leads to dynamic self-organization into several phases with different spatial and temporal order. Using numerical simulations, we present a phase diagram in strain–friction space that shows chaotic dispersion, crystal formation, vortex patterns, and most unusually a disordered phase in which each particle precisely retraces its unique path. However, the system is not reversible. Rather, the trajectory of each particle, and the entire frictional, many–degrees-of-freedom system, organizes itself into a limit cycle absorbing state. Of particular note is that fact that the cyclic states are spatially disordered, whereas the ordered states are chaotic. PMID:25538298

  18. Application of precise altimetry to the study of precise leveling of the sea surface, the Earth's gravity field, and the rotation of the Earth

    NASA Technical Reports Server (NTRS)

    Segawa, J.; Ganeko, Y.; Sasaki, M.; Mori, T.; Ooe, M.; Nakagawa, I.; Ishii, H.; Hagiwara, Y.

    1991-01-01

    Our program includes five research items: (1) determination of a precision geoid and gravity anomaly field; (2) precise leveling and detection of tidal changes of the sea surface and study of the role of the tide in the global energy exchange; (3) oceanic effect on the Earth's rotation and polar motion; (4) geological and geophysical interpretation of the altimetry gravity field; and (5) evaluation of the effectiveness of local tracking of TOPEX/POSEIDON by use of a laser tracker.

  19. The formula for survival in resuscitation.

    PubMed

    Søreide, Eldar; Morrison, Laurie; Hillman, Ken; Monsieurs, Koen; Sunde, Kjetil; Zideman, David; Eisenberg, Mickey; Sterz, Fritz; Nadkarni, Vinay M; Soar, Jasmeet; Nolan, Jerry P

    2013-11-01

    The International Liaison Committee on Resuscitation (ILCOR) Advisory Statement on Education and Resuscitation in 2003 included a hypothetical formula--'the formula for survival' (FfS)--whereby three interactive factors, guideline quality (science), efficient education of patient caregivers (education) and a well-functioning chain of survival at a local level (local implementation), form multiplicands in determining survival from resuscitation. In May 2006, a symposium was held to discuss the validity of the formula for survival hypothesis and to investigate the influence of each of the multiplicands on survival. This commentary combines the output from this symposium with an updated illustration of the three multiplicands in the FfS using rapid response systems (RRS) for medical science, therapeutic hypothermia (TH) for local implementation, and bystander cardiopulmonary resuscitation (CPR) for educational efficiency. International differences between hospital systems made it difficult to assign a precise value for the multiplicand medical science using RRS as an example. Using bystander CPR as an example for the multiplicand educational efficiency, it was also difficult to provide a precise value, mainly because of differences between compression-only and standard CPR. The local implementation multiplicand (exemplified by therapeutic hypothermia) is probably the easiest to improve, and is likely to have the most immediate improvement in observed survival outcome in most systems of care. Despite the noted weaknesses, we believe that the FfS will be useful as a mental framework when trying to improve resuscitation outcome in communities worldwide. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  20. The effect of red cell and plasma transfusion on serum zinc and copper levels in the neonate.

    PubMed

    Lockitch, G; Godolphin, W J; Pendray, M R; Quigley, G

    1983-11-01

    Transfusion of packed red cells (15 to 20 ml/kg) in 11 preterm infants resulted in a slight increase in mean serum zinc levels on the 3rd post transfusion day but no effect was noted on serum copper levels. No significant difference was found between the changes in serum zinc in 141 paired specimens collected a week apart when zero, one, two or three packed cell transfusions were given in the intervening week. A slight decrease in the mean copper level was noted when one transfusion was given. Transfusion of fresh frozen plasma in six newborns with abdominal wall defects resulted in initial serum copper levels two to three times greater than the reference mean for newborns. No effect was noted on zinc levels. Serum copper results should be interpreted with caution in infants who have been transfused with plasma.

  1. Centroiding Experiment for Determining the Positions of Stars with High Precision

    NASA Astrophysics Data System (ADS)

    Yano, T.; Araki, H.; Hanada, H.; Tazawa, S.; Gouda, N.; Kobayashi, Y.; Yamada, Y.; Niwa, Y.

    2010-12-01

    We have experimented with the determination of the positions of star images on a detector with high precision such as 10 microarcseconds, required by a space astrometry satellite, JASMINE. In order to accomplish such a precision, we take the following two procedures. (1) We determine the positions of star images on the detector with the precision of about 0.01 pixel for one measurement, using an algorithm for estimating them from photon weighted means of the star images. (2) We determine the positions of star images with the precision of about 0.0001-0.00001 pixel, which corresponds to that of 10 microarcseconds, using a large amount of data over 10000 measurements, that is, the error of the positions decreases according to the amount of data. Here, we note that the procedure 2 is not accomplished when the systematic error in our data is not excluded adequately even if we use a large amount of data. We first show the method to determine the positions of star images on the detector using photon weighted means of star images. This algorithm, used in this experiment, is very useful because it is easy to calculate the photon weighted mean from the data. This is very important in treating a large amount of data. Furthermore, we need not assume the shape of the point spread function in deriving the centroid of star images. Second, we show the results in the laboratory experiment for precision of determining the positions of star images. We obtain that the precision of estimation of positions of star images on the detector is under a variance of 0.01 pixel for one measurement (procedure 1). We also obtain that the precision of the positions of star images becomes a variance of about 0.0001 pixel using about 10000 measurements (procedure 2).

  2. INTERIOR VIEW OF TANK CHARGING ROOM ON LEVEL 4; NOTE ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    INTERIOR VIEW OF TANK CHARGING ROOM ON LEVEL 4; NOTE HERRINGBONE-PATTERNED BRICK FLOOR; TIMBER SUBSTRUCTURE CARRIED CRANE USED TO REMOVE HEAVY TANK COVERS; WINDOWS IN ROOFTOP MONITOR PROVIDED AMPLE NATURAL LIGHT - Rath Packing Company, Inedible Tank House, Sycamore Street between Elm & Eighteenth Streets, Waterloo, Black Hawk County, IA

  3. A Fixed-Precision Sequential Sampling Plan for the Potato Tuberworm Moth, Phthorimaea operculella Zeller (Lepidoptera: Gelechidae), on Potato Cultivars.

    PubMed

    Shahbi, M; Rajabpour, A

    2017-08-01

    Phthorimaea operculella Zeller is an important pest of potato in Iran. Spatial distribution and fixed-precision sequential sampling for population estimation of the pest on two potato cultivars, Arinda ® and Sante ® , were studied in two separate potato fields during two growing seasons (2013-2014 and 2014-2015). Spatial distribution was investigated by Taylor's power law and Iwao's patchiness. Results showed that the spatial distribution of eggs and larvae was random. In contrast to Iwao's patchiness, Taylor's power law provided a highly significant relationship between variance and mean density. Therefore, fixed-precision sequential sampling plan was developed by Green's model at two precision levels of 0.25 and 0.1. The optimum sample size on Arinda ® and Sante ® cultivars at precision level of 0.25 ranged from 151 to 813 and 149 to 802 leaves, respectively. At 0.1 precision level, the sample sizes varied from 5083 to 1054 and 5100 to 1050 leaves for Arinda ® and Sante ® cultivars, respectively. Therefore, the optimum sample sizes for the cultivars, with different resistance levels, were not significantly different. According to the calculated stop lines, the sampling must be continued until cumulative number of eggs + larvae reached to 15-16 or 96-101 individuals at precision levels of 0.25 or 0.1, respectively. The performance of the sampling plan was validated by resampling analysis using resampling for validation of sampling plans software. The sampling plant provided in this study can be used to obtain a rapid estimate of the pest density with minimal effort.

  4. Field comparison of several commercially available radon detectors.

    PubMed Central

    Field, R W; Kross, B C

    1990-01-01

    To determine the accuracy and precision of commercially available radon detectors in a field setting, 15 detectors from six companies were exposed to radon and compared to a reference radon level. The detectors from companies that had already passed National Radon Measurement Proficiency Program testing had better precision and accuracy than those detectors awaiting proficiency testing. Charcoal adsorption detectors and diffusion barrier charcoal adsorption detectors performed very well, and the latter detectors displayed excellent time averaging ability. Alternatively, charcoal liquid scintillation detectors exhibited acceptable accuracy but poor precision, and bare alpha registration detectors showed both poor accuracy and precision. The mean radon level reported by the bare alpha registration detectors was 68 percent lower than the radon reference level. PMID:2368851

  5. Advanced Unmanned Search System (AUSS) Surface Navigation, Underwater Tracking, and Transponder Network Calibration

    DTIC Science & Technology

    1992-09-01

    5 ENTER PULSE REP PERIOD ................................ 900 ENTER RETURN TO TOP LEVEL C-5 26. SBS1 RECEIVER ----- HYDROPHONE ----- HYDRI ...HYDROPHONE ----- HYDRI PRECISION RETURN 1 LEVEL 29. HEADING INPUT ------ GYRO 1 ------ CONTINUE RANGE GATE OFF ----- FILTER OFF RETURN TO TOP LEVEL 30...700 ENTER RETURN TO TOP LEVEL 12. SBSI RECEIVER ------ HYDROPHONE ------ HYDRI PRECISION RETURN 1 LEVEL 13. HEADING INPUT ------ GYRO 1

  6. NOTE: Total body-calcium measurements: comparison of two delayed-gamma neutron activation facilities

    NASA Astrophysics Data System (ADS)

    Ma, R.; Ellis, K. J.; Yasumura, S.; Shypailo, R. J.; Pierson, R. N., Jr.

    1999-06-01

    This study compares two independently calibrated delayed-gamma neutron activation (DGNA) facilities, one at the Brookhaven National Laboratory (BNL), Upton, New York, and the other at the Children's Nutrition Research Center (CNRC), Houston, Texas that measure total body calcium (TBCa). A set of BNL phantoms was sent to CNRC for neutron activation analysis, and a set of CNRC phantoms was measured at BNL. Both facilities showed high precision (<2%), and the results were in good agreement, within 5%.

  7. A Minimum-Residual Finite Element Method for the Convection-Diffusion Equation

    DTIC Science & Technology

    2013-05-01

    4p . We note that these two choices of discretization for V are not mutually exclusive, and that novel choices for Vh are likely the key to yielding...the inside with the positive- definite operator A, which is precisely the discrete system that arises under the optimal test function framework of DPG...converts the fine-scale problem into a symmetric-positive definite one, allowing for a well-behaved subgrid model of fine scale behavior. We begin again

  8. Note: computer controlled rotation mount for large diameter optics.

    PubMed

    Rakonjac, Ana; Roberts, Kris O; Deb, Amita B; Kjærgaard, Niels

    2013-02-01

    We describe the construction of a motorized optical rotation mount with a 40 mm clear aperture. The device is used to remotely control the power of large diameter laser beams for a magneto-optical trap. A piezo-electric ultrasonic motor on a printed circuit board provides rotation with a precision better than 0.03° and allows for a very compact design. The rotation unit is controlled from a computer via serial communication, making integration into most software control platforms straightforward.

  9. Role of a Novel Family of Short RNAs, tRFs, in Prostate Cancer

    DTIC Science & Technology

    2017-08-01

    SUPPLEMENTARY NOTES 14. ABSTRACT tRFs are precisely generated fragments of tRNA which are shown to function by associating to Argonaute proteins . Unlike...In 2009, Prof. Dutta and colleagues discovered a tRNA related fragment generated from tRNA trailer sequence involved in cell proliferation in...different organisms by mining a number of small RNA-Seq data (Kumar et al. 2014). He also showed that tRFs bind to Argonaute proteins and interacts with its

  10. Actual Operation Simulation of RESSOX Ground Experiments

    DTIC Science & Technology

    2010-11-01

    Note 1289,” (Hewlett-Packard), 60 pp. [5] F. Tappero, A. Dempster, T . Iwata, M. Imae, T . Ikegami , Y. Fukuyama, K. Hagimoto, and A. Iwasaki, 2006...Delay Ionospheric Delay Ku-band Delay Estimation Frequency- Independent part Frequency- Dependent part Elapsed Time with Current Time Set as 0 (s) T ...im e t o b e A d ju s te d 0-6-105 Extrapolated with First- Order Least-Squares Filter Time Adjustment Command 42 nd Annual Precise Time and Time

  11. Application of the Deep Space Network (DSN) to the testing of general relativity

    NASA Technical Reports Server (NTRS)

    Anderson, J. D.; Levy, G. S.; Renzetti, N. A.

    1986-01-01

    The NASA Deep Space Network, a precision telecommunications and radio navigation facility, is described in detail. The first spacecraft relativity test with Mariner 6 and Mariner 7 at solar conjunction is discussed as well as more accurate tests using the Mariner 9 anchored to Mars. Consideration is also given to solar system tests of relativistic celestial mechanics and future prospects. It is noted that the NASA Mars Observer orbital mission is under development and is expected to reach Mars in 1991.

  12. Einstein's equivalence principle in quantum mechanics revisited

    NASA Astrophysics Data System (ADS)

    Nauenberg, Michael

    2016-11-01

    The gravitational equivalence principle in quantum mechanics is of considerable importance, but it is generally not included in physics textbooks. In this note, we present a precise quantum formulation of this principle and comment on its verification in a neutron diffraction experiment. The solution of the time dependent Schrödinger equation for this problem also gives the wave function for the motion of a charged particle in a homogeneous electric field, which is also usually ignored in textbooks on quantum mechanics.

  13. Search for volatiles on icy satellites. I. Europa

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brown, R.H.; Cruikshank, D.P.; Tokunaga, A.T.

    1988-05-01

    NASA IRTF reflectance spectra of unprecedented precision, obtained for the leading and trailing sides of Europa, are presently noted to no longer show the apparent absorptions seen in 1980 and 1985. It is presently suggested that if the weak absorptions seen in the 1980 and 1985 data are real, they may indicate the transient spectroscopic presence of a molecular component on Europa's trailing side that differs from the water ice known to be the dominant constituent of the surface. 33 references.

  14. Proceedings of the Workshop on Improvements to Photometry

    NASA Technical Reports Server (NTRS)

    Borucki, W. J. (Editor); Young, A. T. (Editor)

    1984-01-01

    The purposes of the workshop were to determine what astronomical problems would benefit by increased photometric precision, determine the current level of precision, identify the processes limiting the precision, and recommend approaches to improving photometric precision. Twenty representatives of the university, industry, and government communities participated. Results and recommendations are discussed.

  15. Collection of "Clearinghouse Notes," 1997-98.

    ERIC Educational Resources Information Center

    Education Commission of the States, Denver, CO.

    This document is a collection of Education Commission of the States notes that address a wide array of education issues. The notes provide brief overviews of state legislation passed or pending on specific education issues. It analyzes such matters as performance-based accountability systems; state-level policies regarding accreditation in public…

  16. Precision Health Economics and Outcomes Research to Support Precision Medicine: Big Data Meets Patient Heterogeneity on the Road to Value.

    PubMed

    Chen, Yixi; Guzauskas, Gregory F; Gu, Chengming; Wang, Bruce C M; Furnback, Wesley E; Xie, Guotong; Dong, Peng; Garrison, Louis P

    2016-11-02

    The "big data" era represents an exciting opportunity to utilize powerful new sources of information to reduce clinical and health economic uncertainty on an individual patient level. In turn, health economic outcomes research (HEOR) practices will need to evolve to accommodate individual patient-level HEOR analyses. We propose the concept of "precision HEOR", which utilizes a combination of costs and outcomes derived from big data to inform healthcare decision-making that is tailored to highly specific patient clusters or individuals. To explore this concept, we discuss the current and future roles of HEOR in health sector decision-making, big data and predictive analytics, and several key HEOR contexts in which big data and predictive analytics might transform traditional HEOR into precision HEOR. The guidance document addresses issues related to the transition from traditional to precision HEOR practices, the evaluation of patient similarity analysis and its appropriateness for precision HEOR analysis, and future challenges to precision HEOR adoption. Precision HEOR should make precision medicine more realizable by aiding and adapting healthcare resource allocation. The combined hopes for precision medicine and precision HEOR are that individual patients receive the best possible medical care while overall healthcare costs remain manageable or become more cost-efficient.

  17. Precision Health Economics and Outcomes Research to Support Precision Medicine: Big Data Meets Patient Heterogeneity on the Road to Value

    PubMed Central

    Chen, Yixi; Guzauskas, Gregory F.; Gu, Chengming; Wang, Bruce C. M.; Furnback, Wesley E.; Xie, Guotong; Dong, Peng; Garrison, Louis P.

    2016-01-01

    The “big data” era represents an exciting opportunity to utilize powerful new sources of information to reduce clinical and health economic uncertainty on an individual patient level. In turn, health economic outcomes research (HEOR) practices will need to evolve to accommodate individual patient–level HEOR analyses. We propose the concept of “precision HEOR”, which utilizes a combination of costs and outcomes derived from big data to inform healthcare decision-making that is tailored to highly specific patient clusters or individuals. To explore this concept, we discuss the current and future roles of HEOR in health sector decision-making, big data and predictive analytics, and several key HEOR contexts in which big data and predictive analytics might transform traditional HEOR into precision HEOR. The guidance document addresses issues related to the transition from traditional to precision HEOR practices, the evaluation of patient similarity analysis and its appropriateness for precision HEOR analysis, and future challenges to precision HEOR adoption. Precision HEOR should make precision medicine more realizable by aiding and adapting healthcare resource allocation. The combined hopes for precision medicine and precision HEOR are that individual patients receive the best possible medical care while overall healthcare costs remain manageable or become more cost-efficient. PMID:27827859

  18. Lane-Level Vehicle Positioning : Integrating Diverse Systems for Precision and Reliability

    DOT National Transportation Integrated Search

    2013-05-13

    Integrated global positioning system/inertial navigation system (GPS/INS) technology, the backbone of vehicle positioning systems, cannot provide the precision and reliability needed for vehicle-based, lane-level positioning in all driving environmen...

  19. S100B Serum Levels Predict Treatment Response in Patients with Melancholic Depression

    PubMed Central

    Bergink, Veerle; Grosse, Laura; Alferink, Judith; Drexhage, Hemmo A.; Rothermundt, Matthias; Arolt, Volker; Birkenhäger, Tom K.

    2016-01-01

    Background: There is an ongoing search for biomarkers in psychiatry, for example, as diagnostic tools or predictors of treatment response. The neurotrophic factor S100 calcium binding protein B (S100B) has been discussed as a possible predictor of antidepressant response in patients with major depression, but also as a possible biomarker of an acute depressive state. The aim of the present study was to study the association of serum S100B levels with antidepressant treatment response and depression severity in melancholically depressed inpatients. Methods: After a wash-out period of 1 week, 40 inpatients with melancholic depression were treated with either venlafaxine or imipramine. S100B levels and Hamilton Depression Rating Scale (HAM-D) scores were assessed at baseline, after 7 weeks of treatment, and after 6 months. Results: Patients with high S100B levels at baseline showed a markedly better treatment response defined as relative reduction in HAM-D scores than those with low baseline S100B levels after 7 weeks (P=.002) and 6 months (P=.003). In linear regression models, S100B was a significant predictor for treatment response at both time points. It is of interest to note that nonresponders were detected with a predictive value of 85% and a false negative rate of 7.5%. S100B levels were not associated with depression severity and did not change with clinical improvement. Conclusions: Low S100B levels predict nonresponse to venlafaxine and imipramine with high precision. Future studies have to show which treatments are effective in patients with low levels of S100B so that this biomarker will help to reduce patients’ burden of nonresponding to frequently used antidepressants. PMID:26364276

  20. Study on application of adaptive fuzzy control and neural network in the automatic leveling system

    NASA Astrophysics Data System (ADS)

    Xu, Xiping; Zhao, Zizhao; Lan, Weiyong; Sha, Lei; Qian, Cheng

    2015-04-01

    This paper discusses the adaptive fuzzy control and neural network BP algorithm in large flat automatic leveling control system application. The purpose is to develop a measurement system with a flat quick leveling, Make the installation on the leveling system of measurement with tablet, to be able to achieve a level in precision measurement work quickly, improve the efficiency of the precision measurement. This paper focuses on the automatic leveling system analysis based on fuzzy controller, Use of the method of combining fuzzy controller and BP neural network, using BP algorithm improve the experience rules .Construct an adaptive fuzzy control system. Meanwhile the learning rate of the BP algorithm has also been run-rate adjusted to accelerate convergence. The simulation results show that the proposed control method can effectively improve the leveling precision of automatic leveling system and shorten the time of leveling.

  1. The development of Human Functional Brain Networks

    PubMed Central

    Power, Jonathan D; Fair, Damien A; Schlaggar, Bradley L

    2010-01-01

    Recent advances in MRI technology have enabled precise measurements of correlated activity throughout the brain, leading to the first comprehensive descriptions of functional brain networks in humans. This article reviews the growing literature on the development of functional networks, from infancy through adolescence, as measured by resting state functional connectivity MRI. We note several limitations of traditional approaches to describing brain networks, and describe a powerful framework for analyzing networks, called graph theory. We argue that characterization of the development of brain systems (e.g. the default mode network) should be comprehensive, considering not only relationships within a given system, but also how these relationships are situated within wider network contexts. We note that, despite substantial reorganization of functional connectivity, several large-scale network properties appear to be preserved across development, suggesting that functional brain networks, even in children, are organized in manners similar to other complex systems. PMID:20826306

  2. Note: Real time control of a tunable vibration absorber based on magnetorheological elastomer for suppressing tonal vibrations

    NASA Astrophysics Data System (ADS)

    Kim, Young-Keun; Bae, Hyo-In; Koo, Jeong-Hoi; Kim, Kyung-Soo; Kim, Soohyun

    2012-04-01

    An adaptive tunable vibration absober based on magnetorheological elastomer (MRE) is designed as an intelligent device for auto-tuning itself to the time-varying harmonic disturbance force to reduce the unwanted vibration of the primary system in the steady state. The objectives of this note are to develop and implement a continuous control method for a MRE tunable vibration absorber (TVA) and to evaluate its performance in suppressing time-varying tonal vibrations. In the proposed control, the stiffness of MREs is continuously varied based on a nonlinear tuning function that relates the response of the system to the input magnetic field density. Through experiments, it will be shown that the proposed MRE TVA reduces in real time the transmission of a time-varying excited vibration of 48-55 Hz, which shows the potential applicability of the MRE in reducing unwanted vibration to precision devices.

  3. Georg Philip Nenter and medicine "by notes" in the 18th century.

    PubMed

    Bonfante, Luciana; D'Angelo, Angela; Komninos, Georgios; Antonello, Augusto

    2009-01-01

    Even though it is true that the medical historiography of the 18th century is lacking in great scientific personalities, it is equally true that the entire century is characterized by continuous efforts to encapsulate the medical area of knowledge, acquired until then, in precise and systematic outlines, to serve the academic teaching of the subject of medicine. Georg Philip Nenter, a pupil of Georg Ernst Stahl and a professor of medicine in the University of Strasburg, could not help being influenced by that atmosphere. He added though, in our opinion, a touch of remarkable modernity. In fact his volume Fundamenta medicinae teoretico-pratica (Venice, 1735) is a wonderful collection of the notes taken during his lectures. The description of various diseases - renal diseases in particular - maintains a very systematic development of the subject through various chapters (definition, clinical manifestations, differential diagnosis, prognosis, treatment and examples of specific prescriptions), as if students were being addressed.

  4. Idea units in notes and summaries for read texts by keyboard and pencil in middle childhood students with specific learning disabilities: Cognitive and brain findings

    PubMed Central

    Richards, Todd; Peverly, Stephen; Wolf, Amie; Abbott, Robert; Tanimoto, Steven; Thompson, Rob; Nagy, William; Berninger, Virginia

    2016-01-01

    Seven children with dyslexia and/or dysgraphia (2 girls, 5 boys, M=11 years) completed fMRI connectivity scans before and after twelve weekly computerized lessons in strategies for reading source material, taking notes, and writing summaries by touch typing or groovy pencils. During brain scanning they completed two reading comprehension tasks—one involving single sentences and one involving multiple sentences. From before to after intervention, fMRI connectivity magnitude changed significantly during sentence level reading comprehension (from right angular gyrus→right Broca’s) and during text level reading comprehension (from right angular gyrus→cingulate). Proportions of ideas units in children’s writing compared to idea units in source texts did not differ across combinations of reading-writing tasks and modes. Yet, for handwriting/notes, correlations insignificant before the lessons became significant after the strategy instruction between proportion of idea units and brain connectivity at all levels of language in reading comprehension (word-, sentence-, and text) during scanning; but for handwriting/summaries, touch typing/notes, and touch typing/summaries changes in those correlations from insignificant to significant after strategy instruction occurred only at text level reading comprehension during scanning. Thus, handwriting during note-taking may benefit all levels of language during reading comprehension, whereas all other combinations of modes and writing tasks in this exploratory study appear to benefit only the text level of reading comprehension. Neurological and educational significance of the interdisciplinary research findings for integrating reading and writing and future research directions are discussed. PMID:28133634

  5. Idea units in notes and summaries for read texts by keyboard and pencil in middle childhood students with specific learning disabilities: Cognitive and brain findings.

    PubMed

    Richards, Todd; Peverly, Stephen; Wolf, Amie; Abbott, Robert; Tanimoto, Steven; Thompson, Rob; Nagy, William; Berninger, Virginia

    2016-09-01

    Seven children with dyslexia and/or dysgraphia (2 girls, 5 boys, M =11 years) completed fMRI connectivity scans before and after twelve weekly computerized lessons in strategies for reading source material, taking notes, and writing summaries by touch typing or groovy pencils. During brain scanning they completed two reading comprehension tasks-one involving single sentences and one involving multiple sentences. From before to after intervention, fMRI connectivity magnitude changed significantly during sentence level reading comprehension (from right angular gyrus→right Broca's) and during text level reading comprehension (from right angular gyrus→cingulate). Proportions of ideas units in children's writing compared to idea units in source texts did not differ across combinations of reading-writing tasks and modes. Yet, for handwriting/notes, correlations insignificant before the lessons became significant after the strategy instruction between proportion of idea units and brain connectivity at all levels of language in reading comprehension (word-, sentence-, and text) during scanning; but for handwriting/summaries, touch typing/notes, and touch typing/summaries changes in those correlations from insignificant to significant after strategy instruction occurred only at text level reading comprehension during scanning. Thus, handwriting during note-taking may benefit all levels of language during reading comprehension, whereas all other combinations of modes and writing tasks in this exploratory study appear to benefit only the text level of reading comprehension. Neurological and educational significance of the interdisciplinary research findings for integrating reading and writing and future research directions are discussed.

  6. Reliability of plain radiographic parameters for developmental dysplasia of the hip in children.

    PubMed

    Upasani, Vidyadhar V; Bomar, James D; Parikh, Gaurav; Hosalkar, Harish

    2012-07-01

    Few studies have evaluated the reliability and reproducibility of the femoral neck-shaft angle (NSA), center-edge angle (CEA), and acetabular index (AI) in young children with developmental dysplasia of the hip (DDH). We wanted to determine whether these parameters could be used reliably by practitioners. Fifty radiographs from 21 children with DDH were reviewed. Analysis was performed by three observers, at two time periods. The intra- and inter-observer reliability for each measure was assessed. At time period one, we noted a "high" level of agreement between observers when measuring the NSA, a "low" level when measuring the CEA, and a "moderate" level when measuring the AI. At time period two, we noted a "very high" level of agreement between observers when measuring the NSA and a "high" level when measuring the CEA and AI. When comparing the measurements of observer 1 at the two different time periods, we noted nearly "very high" agreement when measuring the NSA, a "moderate" agreement when measuring the CEA, and a "high" agreement for the AI. In comparing the measurements of observer 2, we noted "very high" agreement for the NSA and "high" agreement for the CEA and AI. In comparing the measurements for observer 3, we noted nearly "very high" agreement for the NSA, nearly "high" agreement for the CEA, and "high" agreement for the AI. It is difficult to reliably measure three-dimensional pelvic morphology on a frontal plane radiograph, especially when important pelvic landmarks have yet to ossify.

  7. Selections from 2017: Image Processing with AstroImageJ

    NASA Astrophysics Data System (ADS)

    Kohler, Susanna

    2017-12-01

    Editors note:In these last two weeks of 2017, well be looking at a few selections that we havent yet discussed on AAS Nova from among the most-downloaded paperspublished in AAS journals this year. The usual posting schedule will resume in January.AstroImageJ: Image Processing and Photometric Extraction for Ultra-Precise Astronomical Light CurvesPublished January2017The AIJ image display. A wide range of astronomy specific image display options and image analysis tools are available from the menus, quick access icons, and interactive histogram. [Collins et al. 2017]Main takeaway:AstroImageJ is a new integrated software package presented in a publication led byKaren Collins(Vanderbilt University,Fisk University, andUniversity of Louisville). Itenables new users even at the level of undergraduate student, high school student, or amateur astronomer to quickly start processing, modeling, and plotting astronomical image data.Why its interesting:Science doesnt just happen the momenta telescope captures a picture of a distantobject. Instead, astronomical images must firstbe carefully processed to clean up thedata, and this data must then be systematically analyzed to learn about the objects within it. AstroImageJ as a GUI-driven, easily installed, public-domain tool is a uniquelyaccessible tool for thisprocessing and analysis, allowing even non-specialist users to explore and visualizeastronomical data.Some features ofAstroImageJ:(as reported by Astrobites)Image calibration:generate master flat, dark, and bias framesImage arithmetic:combineimages viasubtraction, addition, division, multiplication, etc.Stack editing:easily perform operations on a series of imagesImage stabilization and image alignment featuresPrecise coordinate converters:calculate Heliocentric and Barycentric Julian DatesWCS coordinates:determine precisely where atelescope was pointed for an image by PlateSolving using Astronomy.netMacro and plugin support:write your own macrosMulti-aperture photometry with interactive light curve fitting:plot light curves of a star in real timeCitationKaren A. Collins et al 2017 AJ 153 77. doi:10.3847/1538-3881/153/2/77

  8. Notes on testing equality and interval estimation in Poisson frequency data under a three-treatment three-period crossover trial.

    PubMed

    Lui, Kung-Jong; Chang, Kuang-Chao

    2016-10-01

    When the frequency of event occurrences follows a Poisson distribution, we develop procedures for testing equality of treatments and interval estimators for the ratio of mean frequencies between treatments under a three-treatment three-period crossover design. Using Monte Carlo simulations, we evaluate the performance of these test procedures and interval estimators in various situations. We note that all test procedures developed here can perform well with respect to Type I error even when the number of patients per group is moderate. We further note that the two weighted-least-squares (WLS) test procedures derived here are generally preferable to the other two commonly used test procedures in the contingency table analysis. We also demonstrate that both interval estimators based on the WLS method and interval estimators based on Mantel-Haenszel (MH) approach can perform well, and are essentially of equal precision with respect to the average length. We use a double-blind randomized three-treatment three-period crossover trial comparing salbutamol and salmeterol with a placebo with respect to the number of exacerbations of asthma to illustrate the use of these test procedures and estimators. © The Author(s) 2014.

  9. Precision and accuracy of manual water-level measurements taken in the Yucca Mountain area, Nye County, Nevada, 1988-90

    USGS Publications Warehouse

    Boucher, M.S.

    1994-01-01

    Water-level measurements have been made in deep boreholes in the Yucca Mountain area, Nye County, Nevada, since 1983 in support of the U.S. Department of Energy's Yucca Mountain Project, which is an evaluation of the area to determine its suitability as a potential storage area for high-level nuclear waste. Water-level measurements were taken either manually, using various water-level measuring equipment such as steel tapes, or they were taken continuously, using automated data recorders and pressure transducers. This report presents precision range and accuracy data established for manual water-level measurements taken in the Yucca Mountain area, 1988-90. Precision and accuracy ranges were determined for all phases of the water-level measuring process, and overall accuracy ranges are presented. Precision ranges were determined for three steel tapes using a total of 462 data points. Mean precision ranges of these three tapes ranged from 0.014 foot to 0.026 foot. A mean precision range of 0.093 foot was calculated for the multiconductor cable, using 72 data points. Mean accuracy values were calculated on the basis of calibrations of the steel tapes and the multiconductor cable against a reference steel tape. The mean accuracy values of the steel tapes ranged from 0.053 foot, based on three data points to 0.078, foot based on six data points. The mean accuracy of the multiconductor cable was O. 15 foot, based on six data points. Overall accuracy of the water-level measurements was calculated by taking the square root of the sum of the squares of the individual accuracy values. Overall accuracy was calculated to be 0.36 foot for water-level measurements taken with steel tapes, without accounting for the inaccuracy of borehole deviations from vertical. An overall accuracy of 0.36 foot for measurements made with steel tapes is considered satisfactory for this project.

  10. 7 CFR 1951.860 - Interest on loans.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... original note rate of 1 percent interest when they were first issued. The legislation provides for those... same as the original note rate. (2) Loans made in 1983 and 1984 do not automatically qualify for a lower rate than the level of interest rates when the notes were first issued. Section 407 of Pub. L. 99...

  11. 7 CFR 1463.105 - Base quota levels for eligible quota holders.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... the BQL adjustment factor 1.071295. (Note: The factor adjusts the 2004 basic quota to the 2002 basic... farm. (Note: In the case of undivided tract ownership, BQL must be distributed among the tract quota... basic quota, multiplied by the BQL adjustment factor 1.23457. (Note: The factor adjusts the 2004 basic...

  12. 7 CFR 1463.105 - Base quota levels for eligible quota holders.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... the BQL adjustment factor 1.071295. (Note: The factor adjusts the 2004 basic quota to the 2002 basic... farm. (Note: In the case of undivided tract ownership, BQL must be distributed among the tract quota... basic quota, multiplied by the BQL adjustment factor 1.23457. (Note: The factor adjusts the 2004 basic...

  13. 7 CFR 1951.860 - Interest on loans.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... original note rate of 1 percent interest when they were first issued. The legislation provides for those... same as the original note rate. (2) Loans made in 1983 and 1984 do not automatically qualify for a lower rate than the level of interest rates when the notes were first issued. Section 407 of Pub. L. 99...

  14. 7 CFR 1951.860 - Interest on loans.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... original note rate of 1 percent interest when they were first issued. The legislation provides for those... same as the original note rate. (2) Loans made in 1983 and 1984 do not automatically qualify for a lower rate than the level of interest rates when the notes were first issued. Section 407 of Pub. L. 99...

  15. 7 CFR 1951.860 - Interest on loans.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... original note rate of 1 percent interest when they were first issued. The legislation provides for those... same as the original note rate. (2) Loans made in 1983 and 1984 do not automatically qualify for a lower rate than the level of interest rates when the notes were first issued. Section 407 of Pub. L. 99...

  16. Probing the N = 14 subshell closure: g factor of the 26Mg (21+) state

    NASA Astrophysics Data System (ADS)

    McCormick, B. P.; Stuchbery, A. E.; Kibédi, T.; Lane, G. J.; Reed, M. W.; Eriksen, T. K.; Hota, S. S.; Lee, B. Q.; Palalani, N.

    2018-04-01

    The first-excited state g factor of 26Mg has been measured relative to the g factor of the 24Mg (21+) state using the high-velocity transient-field technique, giving g = + 0.86 ± 0.10. This new measurement is in strong disagreement with the currently adopted value, but in agreement with the sd-shell model using the USDB interaction. The newly measured g factor, along with E (21+) and B (E 2) systematics, signal the closure of the νd5/2 subshell at N = 14. The possibility that precise g-factor measurements may indicate the onset of neutron pf admixtures in first-excited state even-even magnesium isotopes below 32Mg is discussed and the importance of precise excited-state g-factor measurements on sd shell nuclei with N ≠ Z to test shell-model wavefunctions is noted.

  17. Note: high precision angle generator using multiple ultrasonic motors and a self-calibratable encoder.

    PubMed

    Kim, Jong-Ahn; Kim, Jae Wan; Kang, Chu-Shik; Jin, Jonghan; Eom, Tae Bong

    2011-11-01

    We present an angle generator with high resolution and accuracy, which uses multiple ultrasonic motors and a self-calibratable encoder. A cylindrical air bearing guides a rotational motion, and the ultrasonic motors achieve high resolution over the full circle range with a simple configuration. The self-calibratable encoder can compensate the scale error of a divided circle (signal period: 20") effectively by applying the equal-division-averaged method. The angle generator configures a position feedback control loop using the readout of the encoder. By combining the ac and dc operation mode, the angle generator produced stepwise angular motion with 0.005" resolution. We also evaluated the performance of the angle generator using a precision angle encoder and an autocollimator. The expanded uncertainty (k = 2) in the angle generation was estimated less than 0.03", which included the calibrated scale error and the nonlinearity error. © 2011 American Institute of Physics

  18. Precision Cosmology: The First Half Million Years

    NASA Astrophysics Data System (ADS)

    Jones, Bernard J. T.

    2017-06-01

    Cosmology seeks to characterise our Universe in terms of models based on well-understood and tested physics. Today we know our Universe with a precision that once would have been unthinkable. This book develops the entire mathematical, physical and statistical framework within which this has been achieved. It tells the story of how we arrive at our profound conclusions, starting from the early twentieth century and following developments up to the latest data analysis of big astronomical datasets. It provides an enlightening description of the mathematical, physical and statistical basis for understanding and interpreting the results of key space- and ground-based data. Subjects covered include general relativity, cosmological models, the inhomogeneous Universe, physics of the cosmic background radiation, and methods and results of data analysis. Extensive online supplementary notes, exercises, teaching materials, and exercises in Python make this the perfect companion for researchers, teachers and students in physics, mathematics, and astrophysics.

  19. Research note: the performance of spring- and summer-reared broilers as affected by precision beak trimming at seven days of age.

    PubMed

    Christmas, R B

    1993-12-01

    In each of two duplicate trials approximately 2,500 day-old Peterson x Arbor Acres straight-run broiler chicks were equally divided between two treatments of three pens each. Treatment 1 was maintained as controls (C), and Treatment 2 birds were precision beak-trimmed (PBT) at 7 days of age. Feed and water were supplied for ad libitum consumption to both groups. Trials 1 and 2 were initiated in March and June, respectively. Performance of spring-reared broilers were comparable regardless of beak trimming procedure, except that PBT broilers experienced slightly higher mortality after PBT. Final body weights of the summer-reared broilers were 15% lower than those reared in the spring. Additionally, PBT resulted in significantly reduced final body weights and feed intake. There were no significant differences in mortality or feed conversion due to PBT.

  20. Virtual Preoperative Planning and Intraoperative Navigation in Facial Prosthetic Reconstruction: A Technical Note.

    PubMed

    Verma, Suzanne; Gonzalez, Marianela; Schow, Sterling R; Triplett, R Gilbert

    This technical protocol outlines the use of computer-assisted image-guided technology for the preoperative planning and intraoperative procedures involved in implant-retained facial prosthetic treatment. A contributing factor for a successful prosthetic restoration is accurate preoperative planning to identify prosthetically driven implant locations that maximize bone contact and enhance cosmetic outcomes. Navigational systems virtually transfer precise digital planning into the operative field for placing implants to support prosthetic restorations. In this protocol, there is no need to construct a physical, and sometimes inaccurate, surgical guide. The report addresses treatment workflow, radiologic data specifications, and special considerations in data acquisition, virtual preoperative planning, and intraoperative navigation for the prosthetic reconstruction of unilateral, bilateral, and midface defects. Utilization of this protocol for the planning and surgical placement of craniofacial bone-anchored implants allows positioning of implants to be prosthetically driven, accurate, precise, and efficient, and leads to a more predictable treatment outcome.

  1. Unlocking echocardiogram measurements for heart disease research through natural language processing.

    PubMed

    Patterson, Olga V; Freiberg, Matthew S; Skanderson, Melissa; J Fodeh, Samah; Brandt, Cynthia A; DuVall, Scott L

    2017-06-12

    In order to investigate the mechanisms of cardiovascular disease in HIV infected and uninfected patients, an analysis of echocardiogram reports is required for a large longitudinal multi-center study. A natural language processing system using a dictionary lookup, rules, and patterns was developed to extract heart function measurements that are typically recorded in echocardiogram reports as measurement-value pairs. Curated semantic bootstrapping was used to create a custom dictionary that extends existing terminologies based on terms that actually appear in the medical record. A novel disambiguation method based on semantic constraints was created to identify and discard erroneous alternative definitions of the measurement terms. The system was built utilizing a scalable framework, making it available for processing large datasets. The system was developed for and validated on notes from three sources: general clinic notes, echocardiogram reports, and radiology reports. The system achieved F-scores of 0.872, 0.844, and 0.877 with precision of 0.936, 0.982, and 0.969 for each dataset respectively averaged across all extracted values. Left ventricular ejection fraction (LVEF) is the most frequently extracted measurement. The precision of extraction of the LVEF measure ranged from 0.968 to 1.0 across different document types. This system illustrates the feasibility and effectiveness of a large-scale information extraction on clinical data. New clinical questions can be addressed in the domain of heart failure using retrospective clinical data analysis because key heart function measurements can be successfully extracted using natural language processing.

  2. On the use of programmable hardware and reduced numerical precision in earth-system modeling.

    PubMed

    Düben, Peter D; Russell, Francis P; Niu, Xinyu; Luk, Wayne; Palmer, T N

    2015-09-01

    Programmable hardware, in particular Field Programmable Gate Arrays (FPGAs), promises a significant increase in computational performance for simulations in geophysical fluid dynamics compared with CPUs of similar power consumption. FPGAs allow adjusting the representation of floating-point numbers to specific application needs. We analyze the performance-precision trade-off on FPGA hardware for the two-scale Lorenz '95 model. We scale the size of this toy model to that of a high-performance computing application in order to make meaningful performance tests. We identify the minimal level of precision at which changes in model results are not significant compared with a maximal precision version of the model and find that this level is very similar for cases where the model is integrated for very short or long intervals. It is therefore a useful approach to investigate model errors due to rounding errors for very short simulations (e.g., 50 time steps) to obtain a range for the level of precision that can be used in expensive long-term simulations. We also show that an approach to reduce precision with increasing forecast time, when model errors are already accumulated, is very promising. We show that a speed-up of 1.9 times is possible in comparison to FPGA simulations in single precision if precision is reduced with no strong change in model error. The single-precision FPGA setup shows a speed-up of 2.8 times in comparison to our model implementation on two 6-core CPUs for large model setups.

  3. Technical note: Coupling infrared gas analysis and cavity ring down spectroscopy for autonomous, high-temporal-resolution measurements of DIC and δ13C-DIC

    NASA Astrophysics Data System (ADS)

    Call, Mitchell; Schulz, Kai G.; Carvalho, Matheus C.; Santos, Isaac R.; Maher, Damien T.

    2017-03-01

    A new approach to autonomously determine concentrations of dissolved inorganic carbon (DIC) and its carbon stable isotope ratio (δ13C-DIC) at high temporal resolution is presented. The simple method requires no customised design. Instead it uses two commercially available instruments currently used in aquatic carbon research. An inorganic carbon analyser utilising non-dispersive infrared detection (NDIR) is coupled to a Cavity Ring-down Spectrometer (CRDS) to determine DIC and δ13C-DIC based on the liberated CO2 from acidified aliquots of water. Using a small sample volume of 2 mL, the precision and accuracy of the new method was comparable to standard isotope ratio mass spectrometry (IRMS) methods. The system achieved a sampling resolution of 16 min, with a DIC precision of ±1.5 to 2 µmol kg-1 and δ13C-DIC precision of ±0.14 ‰ for concentrations spanning 1000 to 3600 µmol kg-1. Accuracy of 0.1 ± 0.06 ‰ for δ13C-DIC based on DIC concentrations ranging from 2000 to 2230 µmol kg-1 was achieved during a laboratory-based algal bloom experiment. The high precision data that can be autonomously obtained by the system should enable complex carbonate system questions to be explored in aquatic sciences using high-temporal-resolution observations.

  4. Spatio-temporal conditional inference and hypothesis tests for neural ensemble spiking precision

    PubMed Central

    Harrison, Matthew T.; Amarasingham, Asohan; Truccolo, Wilson

    2014-01-01

    The collective dynamics of neural ensembles create complex spike patterns with many spatial and temporal scales. Understanding the statistical structure of these patterns can help resolve fundamental questions about neural computation and neural dynamics. Spatio-temporal conditional inference (STCI) is introduced here as a semiparametric statistical framework for investigating the nature of precise spiking patterns from collections of neurons that is robust to arbitrarily complex and nonstationary coarse spiking dynamics. The main idea is to focus statistical modeling and inference, not on the full distribution of the data, but rather on families of conditional distributions of precise spiking given different types of coarse spiking. The framework is then used to develop families of hypothesis tests for probing the spatio-temporal precision of spiking patterns. Relationships among different conditional distributions are used to improve multiple hypothesis testing adjustments and to design novel Monte Carlo spike resampling algorithms. Of special note are algorithms that can locally jitter spike times while still preserving the instantaneous peri-stimulus time histogram (PSTH) or the instantaneous total spike count from a group of recorded neurons. The framework can also be used to test whether first-order maximum entropy models with possibly random and time-varying parameters can account for observed patterns of spiking. STCI provides a detailed example of the generic principle of conditional inference, which may be applicable in other areas of neurostatistical analysis. PMID:25380339

  5. 3-Dimensional printing guide template assisted percutaneous vertebroplasty: Technical note.

    PubMed

    Li, Jian; Lin, JiSheng; Yang, Yong; Xu, JunChuan; Fei, Qi

    2018-06-01

    Percutaneous vertebroplasty (PVP) is currently considered as an effective treatment for pain caused by acute osteoporotic vertebral compression fracture. Recently, puncture-related complications are increasingly reported. It's important to find a precise technique to reduce the puncture-related complications. We report a case and discussed the novel surgical technique with step-by-step operating procedures, to introduce the precise PVP assisted by a 3-dimensional printing guide template. Based on the preoperative CT scan and infrared scan data, a well-designed individual guide template could be established in a 3-dimensional reconstruction software and printed out by a 3-dimensional printer. In real operation, by matching the guide template to patient's back skin, cement needles' insertion orientation and depth were easily established. Only 14 times C-arm fluoroscopy with HDF mode (total exposure dose was 4.5 mSv) were required during the procedure. The operation took only 17 min. Cement distribution in the vertebral body was very good without any puncture-related complications. Pain was significantly relieved after surgery. In conclusion, the novel precise 3-dimensional printing guide template system may allow (1) comprehensive visualization of the fractured vertebral body and the individual surgical planning, (2) the perfect fitting between skin and guide template to ensure the puncture stability and accuracy, and (3) increased puncture precision and decreased puncture-related complications, surgical time and radiation exposure. Copyright © 2018 Elsevier Ltd. All rights reserved.

  6. A Note on Comparing the Power of Test Statistics at Low Significance Levels.

    PubMed

    Morris, Nathan; Elston, Robert

    2011-01-01

    It is an obvious fact that the power of a test statistic is dependent upon the significance (alpha) level at which the test is performed. It is perhaps a less obvious fact that the relative performance of two statistics in terms of power is also a function of the alpha level. Through numerous personal discussions, we have noted that even some competent statisticians have the mistaken intuition that relative power comparisons at traditional levels such as α = 0.05 will be roughly similar to relative power comparisons at very low levels, such as the level α = 5 × 10 -8 , which is commonly used in genome-wide association studies. In this brief note, we demonstrate that this notion is in fact quite wrong, especially with respect to comparing tests with differing degrees of freedom. In fact, at very low alpha levels the cost of additional degrees of freedom is often comparatively low. Thus we recommend that statisticians exercise caution when interpreting the results of power comparison studies which use alpha levels that will not be used in practice.

  7. Influence of MLS laser radiation on erythrocyte membrane fluidity and secondary structure of human serum albumin.

    PubMed

    Pasternak, Kamila; Nowacka, Olga; Wróbel, Dominika; Pieszyński, Ireneusz; Bryszewska, Maria; Kujawa, Jolanta

    2014-03-01

    The biostimulating activity of low level laser radiation of various wavelengths and energy doses is widely documented in the literature, but the mechanisms of the intracellular reactions involved are not precisely known. The aim of this paper is to evaluate the influence of low level laser radiation from an multiwave locked system (MLS) of two wavelengths (wavelength = 808 nm in continuous emission and 905 nm in pulsed emission) on the human erythrocyte membrane and on the secondary structure of human serum albumin (HSA). Human erythrocytes membranes and HSA were irradiated with laser light of low intensity with surface energy density ranging from 0.46 to 4.9 J cm(-2) and surface energy power density 195 mW cm(-2) (1,000 Hz) and 230 mW cm(-2) (2,000 Hz). Structural and functional changes in the erythrocyte membrane were characterized by its fluidity, while changes in the protein were monitored by its secondary structure. Dose-dependent changes in erythrocyte membrane fluidity were induced by near-infrared laser radiation. Slight changes in the secondary structure of HSA were also noted. MLS laser radiation influences the structure and function of the human erythrocyte membrane resulting in a change in fluidity.

  8. System precisely controls oscillation of vibrating mass

    NASA Technical Reports Server (NTRS)

    Hancock, D. J.

    1967-01-01

    System precisely controls the sinusoidal amplitude of a vibrating mechanical mass. Using two sets of coils, the system regulates the drive signal amplitude at the precise level to maintain the mechanical mass when it reaches the desired vibration amplitude.

  9. Heavy duty precision leveling jacks expedite setup time on horizontal boring mill

    NASA Technical Reports Server (NTRS)

    Dellenbaugh, W.; Jones, C.

    1966-01-01

    Leveling jack is a precise alignment tool which expedites the setup of components or assemblies up to 2500 pounds on horizontal boring mills. This tool eliminates the necessity of wedges and blocks to shim the components to proper position.

  10. Characterizing Accuracy and Precision of Glucose Sensors and Meters

    PubMed Central

    2014-01-01

    There is need for a method to describe precision and accuracy of glucose measurement as a smooth continuous function of glucose level rather than as a step function for a few discrete ranges of glucose. We propose and illustrate a method to generate a “Glucose Precision Profile” showing absolute relative deviation (ARD) and /or %CV versus glucose level to better characterize measurement errors at any glucose level. We examine the relationship between glucose measured by test and comparator methods using linear regression. We examine bias by plotting deviation = (test – comparator method) versus glucose level. We compute the deviation, absolute deviation (AD), ARD, and standard deviation (SD) for each data pair. We utilize curve smoothing procedures to minimize the effects of random sampling variability to facilitate identification and display of the underlying relationships between ARD or %CV and glucose level. AD, ARD, SD, and %CV display smooth continuous relationships versus glucose level. Estimates of MARD and %CV are subject to relatively large errors in the hypoglycemic range due in part to a markedly nonlinear relationship with glucose level and in part to the limited number of observations in the hypoglycemic range. The curvilinear relationships of ARD and %CV versus glucose level are helpful when characterizing and comparing the precision and accuracy of glucose sensors and meters. PMID:25037194

  11. ESTIMATING SAMPLE REQUIREMENTS FOR FIELD EVALUATIONS OF PESTICIDE LEACHING

    EPA Science Inventory

    A method is presented for estimating the number of samples needed to evaluate pesticide leaching threats to ground water at a desired level of precision. Sample size projections are based on desired precision (exhibited as relative tolerable error), level of confidence (90 or 95%...

  12. RCS tests utilize ground-plane effects

    NASA Astrophysics Data System (ADS)

    Knott, E. F.

    1984-03-01

    It is noted that the ground effects must be thoroughly understood to attain the proper radar cross section (RCS) configurations for a specific test. If the ground is sufficiently smooth, it acts as a mirror. Ground reflections then serve to enhance the incident field strength. If an asphalt or concrete ground plane has not been constructed, the soil must be kept free of vegetation and must be graded and leveled to exploit the effect. To elucidate the role of the ground plane, the various ways that energy propagates to the target and back are considered. In implementing a ground-plane RCS measurement program, it is important that the target height, antenna height, target range, and radar wavelength be chosen so as to place the target at a peak in the interference pattern. It is pointed out that in order to maximize the received signal, the antenna should be depressed below the bisector of the angle between the direct and indirect paths subtended at the radar receiving antenna. The precise amount of depression depends on the antenna radiation pattern.

  13. Profile surveys along Henrys Fork, Idaho, and Logan River and Blacksmith Fork, Utah

    USGS Publications Warehouse

    Herron, William Harrison

    1916-01-01

    In order to determine the location of undeveloped water powers the United States Geological Survey has from time to time, alone and in cooperation with State organizations, made surveys and profiles of some of the rivers of the United States that are adapted to the development of power by low or medium heads of 20 to 100 feet.The surveys are made by means of plane table and stadia. Elevations are based on heights derived from primary or precise levels of the United States Geological Survey. The maps/are made in the field, and show not only the outlines of the river banks, the islands, the positions of rapids/falls, shoals, and existing dams, and the crossings of all ferries and roads, but the contours of banks to an elevation high enough to indicate the possibility of using the stream. The elevations of the various bench marks left are noted on the field sheets in their proper positions. The figures given with the gaging stations shown on the maps indicate the elevation of the zero of the gage.

  14. [Reconciling activities of working women providing care and the influence of structural and cultural factors].

    PubMed

    Preuß, M

    2015-07-01

    Today, an increasing proportion of society has to reconcile eldercare and work. This task poses challenges for them, which they meet through an adjustment of their everyday living arrangements. These coping strategies have been so far scarcely noted within research on the reconciliation of elder care and employment. Knowledge about the active dealing with this parallel involvement in both spheres of life is of vital importance when wanting to derive precisely tailored support measures for employed care givers. A goal of this article is to deliver insight on reconciling activities of employed women who provide care, while it tries to specify respective factors which determine those actions. Moreover, an ideal typology is presented, which systematizes these associations. With this ideal typology, conceptual instruments have been developed which illustrate the complex reality of the reconciliation actions and the dependence on various coping resources. In gerontological practice, these findings may provide support to design an intervention strategy tailored to the individual situation that addresses the everyday level of action and strengthens the performance of those affected.

  15. LUVOIR Tech Notes

    NASA Technical Reports Server (NTRS)

    Bolcar, Matthew R.; Shaklan, Stuart; Roberge, Aki; Rioux, Norman; Feinberg, Lee; Werner, Michael; Rauscher, Bernard; Mandell, Avi; France, Kevin; Schiminovich, David

    2016-01-01

    We present nine "tech notes" prepared by the Large UV/Optical/Infrared (LUVOIR) Science and Technology Definition Team (STDT), Study Office, and Technology Working Group. These tech notes are intended to highlight technical challenges that represent boundaries in the trade space for developing the LUVOIR architecture that may impact the science objectives being developed by the STDT. These tech notes are intended to be high-level discussions of the technical challenges and will serve as starting points for more in-depth analysis as the LUVOIR study progresses.

  16. A randomized comparison of laparoscopic, flexible endoscopic, and wired and wireless magnetic cameras on ex vivo and in vivo NOTES surgical performance.

    PubMed

    Chang, Victoria C; Tang, Shou-Jiang; Swain, C Paul; Bergs, Richard; Paramo, Juan; Hogg, Deborah C; Fernandez, Raul; Cadeddu, Jeffrey A; Scott, Daniel J

    2013-08-01

    The influence of endoscopic video camera (VC) image quality on surgical performance has not been studied. Flexible endoscopes are used as substitutes for laparoscopes in natural orifice translumenal endoscopic surgery (NOTES), but their optics are originally designed for intralumenal use. Manipulable wired or wireless independent VCs might offer advantages for NOTES but are still under development. To measure the optical characteristics of 4 VC systems and to compare their impact on the performance of surgical suturing tasks. VC systems included a laparoscope (Storz 10 mm), a flexible endoscope (Olympus GIF 160), and 2 prototype deployable cameras (magnetic anchoring and guidance system [MAGS] Camera and PillCam). In a randomized fashion, the 4 systems were evaluated regarding standardized optical characteristics and surgical manipulations of previously validated ex vivo (fundamentals of laparoscopic surgery model) and in vivo (live porcine Nissen model) tasks; objective metrics (time and errors/precision) and combined surgeon (n = 2) performance were recorded. Subtle differences were detected for color tests, and field of view was variable (65°-115°). Suitable resolution was detected up to 10 cm for the laparoscope and MAGS camera but only at closer distances for the endoscope and PillCam. Compared with the laparoscope, surgical suturing performances were modestly lower for the MAGS camera and significantly lower for the endoscope (ex vivo) and PillCam (ex vivo and in vivo). This study documented distinct differences in VC systems that may be used for NOTES in terms of both optical characteristics and surgical performance. Additional work is warranted to optimize cameras for NOTES. Deployable systems may be especially well suited for this purpose.

  17. Precision Medicine: Functional Advancements.

    PubMed

    Caskey, Thomas

    2018-01-29

    Precision medicine was conceptualized on the strength of genomic sequence analysis. High-throughput functional metrics have enhanced sequence interpretation and clinical precision. These technologies include metabolomics, magnetic resonance imaging, and I rhythm (cardiac monitoring), among others. These technologies are discussed and placed in clinical context for the medical specialties of internal medicine, pediatrics, obstetrics, and gynecology. Publications in these fields support the concept of a higher level of precision in identifying disease risk. Precise disease risk identification has the potential to enable intervention with greater specificity, resulting in disease prevention-an important goal of precision medicine.

  18. Review and Process Effects of Spontaneous Note-Taking on Text Comprehension.

    PubMed

    Slotte; Lonka

    1999-01-01

    This study examines how quantitative and qualitative differences in spontaneously taken notes are related to text comprehension in combination with reviewing or not reviewing previously made notes. High school graduates (N = 226) were allowed to take notes in any way they desired while reading a philosophical text. Approximately half the participants were told that they could review their notes during writing tasks designed to measure the ability to define, compare, and evaluate text content. The other half of the participants answered the subsequent questions without their notes. The process of taking notes was rated on the basis of note quality and quantity. The results revealed significant review and process effects in spontaneous note-taking. Reviewing the notes during essay-writing generally resulted in good performance in an exam calling for deep-level text comprehension. However, this review effect was mainly limited to detailed learning instead of making one's own inferences. Results pertaining to note quality indicated that the participants who summarized the content of the text resulted in better performance in all tasks in comparison with those who produced notes following the text order or verbatim notes. The amount of note-taking was also positively related to text comprehension. The discussion focuses upon the situational appropriateness of note-taking effects that pose challenges to educators. Copyright 1999 Academic Press.

  19. The Frontier Fields lens modelling comparison project

    NASA Astrophysics Data System (ADS)

    Meneghetti, M.; Natarajan, P.; Coe, D.; Contini, E.; De Lucia, G.; Giocoli, C.; Acebron, A.; Borgani, S.; Bradac, M.; Diego, J. M.; Hoag, A.; Ishigaki, M.; Johnson, T. L.; Jullo, E.; Kawamata, R.; Lam, D.; Limousin, M.; Liesenborgs, J.; Oguri, M.; Sebesta, K.; Sharon, K.; Williams, L. L. R.; Zitrin, A.

    2017-12-01

    Gravitational lensing by clusters of galaxies offers a powerful probe of their structure and mass distribution. Several research groups have developed techniques independently to achieve this goal. While these methods have all provided remarkably high-precision mass maps, particularly with exquisite imaging data from the Hubble Space Telescope (HST), the reconstructions themselves have never been directly compared. In this paper, we present for the first time a detailed comparison of methodologies for fidelity, accuracy and precision. For this collaborative exercise, the lens modelling community was provided simulated cluster images that mimic the depth and resolution of the ongoing HST Frontier Fields. The results of the submitted reconstructions with the un-blinded true mass profile of these two clusters are presented here. Parametric, free-form and hybrid techniques have been deployed by the participating groups and we detail the strengths and trade-offs in accuracy and systematics that arise for each methodology. We note in conclusion that several properties of the lensing clusters are recovered equally well by most of the lensing techniques compared in this study. For example, the reconstruction of azimuthally averaged density and mass profiles by both parametric and free-form methods matches the input models at the level of ∼10 per cent. Parametric techniques are generally better at recovering the 2D maps of the convergence and of the magnification. For the best-performing algorithms, the accuracy in the magnification estimate is ∼10 per cent at μtrue = 3 and it degrades to ∼30 per cent at μtrue ∼ 10.

  20. Thoracic, Lumbar, and Sacral Pedicle Screw Placement Using Stryker-Ziehm Virtual Screw Technology and Navigated Stryker Cordless Driver 3: Technical Note.

    PubMed

    Satarasinghe, Praveen; Hamilton, Kojo D; Tarver, Michael J; Buchanan, Robert J; Koltz, Michael T

    2018-04-17

    Utilization of pedicle screws (PS) for spine stabilization is common in spinal surgery. With reliance on visual inspection of anatomical landmarks prior to screw placement, the free-hand technique requires a high level of surgeon skill and precision. Three-dimensional (3D), computer-assisted virtual neuronavigation improves the precision of PS placement and minimization steps. Twenty-three patients with degenerative, traumatic, or neoplastic pathologies received treatment via a novel three-step PS technique that utilizes a navigated power driver in combination with virtual screw technology. (1) Following visualization of neuroanatomy using intraoperative CT, a navigated 3-mm match stick drill bit was inserted at an anatomical entry point with a screen projection showing a virtual screw. (2) A Navigated Stryker Cordless Driver with an appropriate tap was used to access the vertebral body through a pedicle with a screen projection again showing a virtual screw. (3) A Navigated Stryker Cordless Driver with an actual screw was used with a screen projection showing the same virtual screw. One hundred and forty-four consecutive screws were inserted using this three-step, navigated driver, virtual screw technique. Only 1 screw needed intraoperative revision after insertion using the three-step, navigated driver, virtual PS technique. This amounts to a 0.69% revision rate. One hundred percent of patients had intraoperative CT reconstructed images taken to confirm hardware placement. Pedicle screw placement utilizing the Stryker-Ziehm neuronavigation virtual screw technology with a three step, navigated power drill technique is safe and effective.

  1. On the Relationship Between Generalization Error, Hypothesis Complexity, and Sample Complexity for Radial Basis Functions

    DTIC Science & Technology

    1994-01-01

    torque general nature. We then provide in section 3 a precise at a particular joint of a robot arm , and x the set of an- statement of a specific...sampling Y according to first need to introduce some terminology and to define P(ylx). In the robot arm example described above, it a number of...mathematical objects. A summary of the would mean that one could move the robot arm into most common notations and definitions used in this pa- ’Note that

  2. Laser speckle technique for burner liner strain measurements

    NASA Technical Reports Server (NTRS)

    Stetson, K. A.

    1982-01-01

    Thermal and mechanical strains were measured on samples of a common material used in jet engine burner liners, which were heated from room temperature to 870 C and cooled back to 220 C, in a laboratory furnance. The physical geometry of the sample surface was recorded at selected temperatures by a set of 12 single exposure speckle-grams. Sequential pairs of specklegrams were compared in a heterodyne interferometer which give high precision measurement of differential displacements. Good speckle correlation between the first and last specklegrams is noted which allows a check on accumulate errors.

  3. Note: Evaluation of microfracture strength of diamond materials using nano-polycrystalline diamond spherical indenter

    NASA Astrophysics Data System (ADS)

    Sumiya, H.; Hamaki, K.; Harano, K.

    2018-05-01

    Ultra-hard and high-strength spherical indenters with high precision and sphericity were successfully prepared from nanopolycrystalline diamond (NPD) synthesized by direct conversion sintering from graphite under high pressure and high temperature. It was shown that highly accurate and stable microfracture strength tests can be performed on various super-hard diamond materials by using the NPD spherical indenters. It was also verified that this technique enables quantitative evaluation of the strength characteristics of single crystal diamonds and NPDs which have been quite difficult to evaluate.

  4. Toward a characterization of landscapes of combinatorial optimization problems, with special attention to the phylogeny problem.

    PubMed

    Charleston, M A

    1995-01-01

    This article introduces a coherent language base for describing and working with characteristics of combinatorial optimization problems, which is at once general enough to be used in all such problems and precise enough to allow subtle concepts in this field to be discussed unambiguously. An example is provided of how this nomenclature is applied to an instance of the phylogeny problem. Also noted is the beneficial effect, on the landscape of the solution space, of transforming the observed data to account for multiple changes of character state.

  5. Development of cable drive systems for an automated assembly project

    NASA Technical Reports Server (NTRS)

    Monroe, Charles A., Jr.

    1990-01-01

    In a robotic assembly project, a method was needed to accurately position a robot and a structure which the robot was to assemble. The requirements for high precision and relatively long travel distances dictated the use of cable drive systems. The design of the mechanisms used in translating the robot and in rotating the assembly under construction is discussed. The design criteria are discussed, and the effect of particular requirements on the design is noted. Finally, the measured performance of the completed mechanism is compared with design requirements.

  6. Mobile geophysics for searching and exploration of Domanic hydrocarbon deposits

    NASA Astrophysics Data System (ADS)

    Borovsky, M. Ya; Uspensky, B. V.; Valeeva, S. E.; Borisov, A. S.

    2018-05-01

    There are noted features of shale hydrocarbons occurrence. It is shown the role of geophysical prospecting in the geological prospecting process for non-traditional sources of hydrocarbon. There are considered the possibilities of non-seismic methods for forecasting, prospecting, exploration and preparation of Domanikovian hydrocarbons accumulations for exploration. It is emphasized the need for geophysical studies of tectonic disturbances. Modern aerogeophysical instrumentation and methodological support allows to combine high-precision magneto-prospecting with gravimetric and gamma spectrometry. This combination of geophysical methods contributes to the diagnosis of active and latent faults.

  7. Note: Ultra-low birefringence dodecagonal vacuum glass cell.

    PubMed

    Brakhane, Stefan; Alt, Wolfgang; Meschede, Dieter; Robens, Carsten; Moon, Geol; Alberti, Andrea

    2015-12-01

    We report on an ultra-low birefringence dodecagonal glass cell for ultra-high vacuum applications. The epoxy-bonded trapezoidal windows of the cell are made of SF57 glass, which exhibits a very low stress-induced birefringence. We characterize the birefringence Δn of each window with the cell under vacuum conditions, obtaining values around 10(-8). After baking the cell at 150 °C, we reach a pressure below 10(-10) mbar. In addition, each window is antireflection coated on both sides, which is highly desirable for quantum optics experiments and precision measurements.

  8. Proceedings of the Annual Precise Time and Time Interval (PTTI) applications and Planning Meeting (21st), Held in Redondo Beach, California on November 28-30, 1989

    DTIC Science & Technology

    1989-01-01

    Duke University Mr. Philip E. Talley Aerospace NOTE: NON-GOVERNMENT OFFICERS OF THE PITI ARE AUTOMATICALLY MEMBERS OF THE PTTI ADVISORY BOARD FOR THE...2763 Hughes Aircraft Space and Communications Mr. Philip E. Talley S12/W322, P. 0. Box 92919 The Aerospace Corporation Los Angeles, California 90009 550...and Mr. G.J. Trudeau for the mechanical construction of the masers, Mr. M. Kotler for assistance with the mechanical design, and Mr. W. Cazemier and

  9. Identification of 4U 1849-31 with V1223 Sagittarii and discovery of optical pulsations

    NASA Technical Reports Server (NTRS)

    Steiner, J. E.; Schwartz, D. A.; Jablonski, F. J.; Busko, I. C.; Watson, M. G.; Pye, J. P.; Mchardy, I. M.

    1981-01-01

    The X-ray source 4U 1849-31 is identified with the 13 mag star V1223 Sgr, on the basis of a precise HEAO 1 modulation collimator X-ray position uniquely selected by the Ariel-5 sky survey location. It is shown by optical spectroscopy and photometry that V1223 Sgr is a cataclysmic variable, displaying a photometric period of 13.2 min that is interpreted as being due to the rotation of a degenerate dwarf. The similarity of this system to H2252-035 is noted.

  10. Optimal Design for Two-Level Random Assignment and Regression Discontinuity Studies

    ERIC Educational Resources Information Center

    Rhoads, Christopher H.; Dye, Charles

    2016-01-01

    An important concern when planning research studies is to obtain maximum precision of an estimate of a treatment effect given a budget constraint. When research designs have a "multilevel" or "hierarchical" structure changes in sample size at different levels of the design will impact precision differently. Furthermore, there…

  11. The effects of immersiveness on physiology.

    PubMed

    Wiederhold, B K; Davis, R; Wiederhold, M D

    1998-01-01

    The effects of varying levels of immersion in virtual reality environments on participant's heart rate, respiration rate, peripheral skin temperature, and skin resistance levels were examined. Subjective reports of presence were also noted. Participants were presented with a virtual environment of an airplane flight both as seen from a two-dimensional computer screen and as seen from within a head-mounted display. Subjects were randomly assigned to different order of conditions presented, but all subjects received both conditions. Differences between the non-phobics' physiological responses and the phobic's response when placed in a virtual environment related to the phobia were noted. Also noted were changes in physiology based on degree of immersion.

  12. FAST CHOPPER BUILDING, TRA665, INTERIOR. LOWER (DETECTOR) LEVEL. NOTE BRICKEDIN ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    FAST CHOPPER BUILDING, TRA-665, INTERIOR. LOWER (DETECTOR) LEVEL. NOTE BRICKED-IN WINDOW ON MTR SIDE. USED FOR STORAGE OF LEAD BRICKS AFTER EXPERIMENTAL NEUTRON INSTRUMENTS WERE REMOVED. SIGN SAYS "IN-PROCESS LEAD SOURCE STORAGE." INL NEGATIVE NO. HD-42-2. Mike Crane, Photographer, 3/2004 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID

  13. Error analysis of high-rate GNSS precise point positioning for seismic wave measurement

    NASA Astrophysics Data System (ADS)

    Shu, Yuanming; Shi, Yun; Xu, Peiliang; Niu, Xiaoji; Liu, Jingnan

    2017-06-01

    High-rate GNSS precise point positioning (PPP) has been playing a more and more important role in providing precise positioning information in fast time-varying environments. Although kinematic PPP is commonly known to have a precision of a few centimeters, the precision of high-rate PPP within a short period of time has been reported recently with experiments to reach a few millimeters in the horizontal components and sub-centimeters in the vertical component to measure seismic motion, which is several times better than the conventional kinematic PPP practice. To fully understand the mechanism of mystified excellent performance of high-rate PPP within a short period of time, we have carried out a theoretical error analysis of PPP and conducted the corresponding simulations within a short period of time. The theoretical analysis has clearly indicated that the high-rate PPP errors consist of two types: the residual systematic errors at the starting epoch, which affect high-rate PPP through the change of satellite geometry, and the time-varying systematic errors between the starting epoch and the current epoch. Both the theoretical error analysis and simulated results are fully consistent with and thus have unambiguously confirmed the reported high precision of high-rate PPP, which has been further affirmed here by the real data experiments, indicating that high-rate PPP can indeed achieve the millimeter level of precision in the horizontal components and the sub-centimeter level of precision in the vertical component to measure motion within a short period of time. The simulation results have clearly shown that the random noise of carrier phases and higher order ionospheric errors are two major factors to affect the precision of high-rate PPP within a short period of time. The experiments with real data have also indicated that the precision of PPP solutions can degrade to the cm level in both the horizontal and vertical components, if the geometry of satellites is rather poor with a large DOP value.

  14. Regulation of alternative splicing at the single-cell level.

    PubMed

    Faigenbloom, Lior; Rubinstein, Nimrod D; Kloog, Yoel; Mayrose, Itay; Pupko, Tal; Stein, Reuven

    2015-12-28

    Alternative splicing is a key cellular mechanism for generating distinct isoforms, whose relative abundances regulate critical cellular processes. It is therefore essential that inclusion levels of alternative exons be tightly regulated. However, how the precision of inclusion levels among individual cells is governed is poorly understood. Using single-cell gene expression, we show that the precision of inclusion levels of alternative exons is determined by the degree of evolutionary conservation at their flanking intronic regions. Moreover, the inclusion levels of alternative exons, as well as the expression levels of the transcripts harboring them, also contribute to this precision. We further show that alternative exons whose inclusion levels are considerably changed during stem cell differentiation are also subject to this regulation. Our results imply that alternative splicing is coordinately regulated to achieve accuracy in relative isoform abundances and that such accuracy may be important in determining cell fate. © 2015 The Authors. Published under the terms of the CC BY 4.0 license.

  15. The clinical relevance of plasma CD147/basigin in biopsy-proven kidney diseases.

    PubMed

    Mori, Yoshiko; Masuda, Tomohiro; Kosugi, Tomoki; Yoshioka, Tomoki; Hori, Mayuko; Nagaya, Hiroshi; Maeda, Kayaho; Sato, Yuka; Kojima, Hiroshi; Kato, Noritoshi; Ishimoto, Takuji; Katsuno, Takayuki; Yuzawa, Yukio; Kadomatsu, Kenji; Maruyama, Shoichi

    2017-12-12

    Precise understanding of kidney disease activity is needed to design therapeutic strategies. CD147/basigin is involved in the pathogenesis of acute kidney injury and renal fibrosis through inflammatory cell infiltration. The present study examined the clinical relevance of CD147 in biopsy-proven kidney diseases that lead to the progression of chronic kidney disease. Kidney biopsy specimens and plasma and urine samples were obtained from patients with kidney diseases, including IgA nephropathy (IgAN), Henoch-Schönlein purpura nephritis (HSPN), diabetic kidney disease (DKD), focal segmental glomerulosclerosis (FSGS), and membranous nephropathy (MN), who underwent renal biopsy between 2011 and 2014. Plasma and urinary CD147 levels were measured and evaluated for their ability to reflect histological features. Disease activity of IgAN tissues was evaluated according to the Oxford classification and the Japanese histological grading system. In biopsy tissues, CD147 induction was detected in injured lesions representing renal inflammation. Plasma CD147 values correlated with eGFR in patients with inflammation-related kidney diseases such as IgAN, HSPN, and DKD. Particularly in IgAN patients, plasma CD147 levels were correlated with injured regions comprising more than 50% of glomeruli or with tubular atrophy/interstitial injury in biopsy tissues. Proteinuria showed a closer correlation with urinary values of CD147 and L-FABP. Of note, plasma and urinary CD147 levels showed a strong correlation with eGFR or proteinuria, respectively, only in DKD patients. Evaluation of plasma and urinary CD147 levels might provide key insights for the understanding of the activity of various kidney diseases.

  16. High-precision R-branch transition frequencies in the ν2 fundamental band of H 3+ %A Perry, Adam J.; Hodges, James N.; Markus, Charles R.; Kocheril, G. Stephen; McCall, Benjamin J.

    NASA Astrophysics Data System (ADS)

    Perry, Adam J.; Hodges, James N.; Markus, Charles R.; Kocheril, G. Stephen; McCall, Benjamin J.

    2015-11-01

    The H3+ molecular ion has served as a long-standing benchmark for state-of-the-art ab initio calculations of molecular potentials and variational calculations of rovibrational energy levels. However, the accuracy of such calculations would not have been confirmed if not for the wealth of spectroscopic data that has been made available for this molecule. Recently, a new high-precision ion spectroscopy technique was demonstrated by Hodges et al., which led to the first highly accurate and precise (∼MHz) H3+ transition frequencies. As an extension of this work, we present ten additional R-branch transitions measured to similar precision as a next step toward the ultimate goal of producing a comprehensive high-precision survey of this molecule, from which rovibrational energy levels can be calculated.

  17. [Application of artificial neural networks in forecasting the number of circulatory system diseases death toll].

    PubMed

    Zhang, Ying; Shao, Yi; Shang, Kezheng; Wang, Shigong; Wang, Jinyan

    2014-09-01

    Set up the model of forecasting the number of circulatorys death toll based on back-propagation (BP) artificial neural networks discuss the relationship between the circulatory system diseases death toll meteorological factors and ambient air pollution. The data of tem deaths, meteorological factors, and ambient air pollution within the m 2004 to 2009 in Nanjing were collected. On the basis of analyzing the ficient between CSDDT meteorological factors and ambient air pollution, leutral network model of CSDDT was built for 2004 - 2008 based on factors and ambient air pollution within the same time, and the data of 2009 est the predictive power of the model. There was a closely system diseases relationship between meteorological factors, ambient air pollution and the circulatory system diseases death toll. The ANN model structure was 17 -16 -1, 17 input notes, 16 hidden notes and 1 output note. The training precision was 0. 005 and the final error was 0. 004 999 42 after 487 training steps. The results of forecast show that predict accuracy over 78. 62%. This method is easy to be finished with smaller error, and higher ability on circulatory system death toll on independent prediction, which can provide a new method for forecasting medical-meteorological forecast and have the value of further research.

  18. Assessment of commercial NLP engines for medication information extraction from dictated clinical notes.

    PubMed

    Jagannathan, V; Mullett, Charles J; Arbogast, James G; Halbritter, Kevin A; Yellapragada, Deepthi; Regulapati, Sushmitha; Bandaru, Pavani

    2009-04-01

    We assessed the current state of commercial natural language processing (NLP) engines for their ability to extract medication information from textual clinical documents. Two thousand de-identified discharge summaries and family practice notes were submitted to four commercial NLP engines with the request to extract all medication information. The four sets of returned results were combined to create a comparison standard which was validated against a manual, physician-derived gold standard created from a subset of 100 reports. Once validated, the individual vendor results for medication names, strengths, route, and frequency were compared against this automated standard with precision, recall, and F measures calculated. Compared with the manual, physician-derived gold standard, the automated standard was successful at accurately capturing medication names (F measure=93.2%), but performed less well with strength (85.3%) and route (80.3%), and relatively poorly with dosing frequency (48.3%). Moderate variability was seen in the strengths of the four vendors. The vendors performed better with the structured discharge summaries than with the clinic notes in an analysis comparing the two document types. Although automated extraction may serve as the foundation for a manual review process, it is not ready to automate medication lists without human intervention.

  19. Environmental effects of dredging: Methods for the assessment of the genotoxic effects of environmental contaminants. Glossary and references. Technical notes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Honeycutt, M.E.; Jarvis, A.S.; McFarland, V.A.

    1995-07-01

    This technical note is the third in a series of three that outline and describe the principal methods that have been developed to test the potential of environmental contaminants to cause mutagenic, carcinogenic, and teratogenic effects. The first in this series (EEDP-04-24) describes methods used to discern genotoxic effects at the sub cellular level, while the second (EEDP-04-25) describes methods used to discern genotoxic effects at the cellular and organ/organism level. Recent literature citations for each topic referenced in this series of technical notes are provided in this technical note, in addition to a glossary of terms. The information inmore » these technical notes is intended to provide Corps of Engineers personnel with a working knowledge of the terminology and conceptual basis of genotoxicity testing. To develop an improved understanding of the concepts of genotoxicity, readers are encouraged to review A Primer in Genotoxicity (Jarvis, Reilly, and Lutz 1993), presented in Volume D-93-3 of the Environmental Effects of Dredging information exchange bulletin.« less

  20. Machine Learning in Medical Imaging.

    PubMed

    Giger, Maryellen L

    2018-03-01

    Advances in both imaging and computers have synergistically led to a rapid rise in the potential use of artificial intelligence in various radiological imaging tasks, such as risk assessment, detection, diagnosis, prognosis, and therapy response, as well as in multi-omics disease discovery. A brief overview of the field is given here, allowing the reader to recognize the terminology, the various subfields, and components of machine learning, as well as the clinical potential. Radiomics, an expansion of computer-aided diagnosis, has been defined as the conversion of images to minable data. The ultimate benefit of quantitative radiomics is to (1) yield predictive image-based phenotypes of disease for precision medicine or (2) yield quantitative image-based phenotypes for data mining with other -omics for discovery (ie, imaging genomics). For deep learning in radiology to succeed, note that well-annotated large data sets are needed since deep networks are complex, computer software and hardware are evolving constantly, and subtle differences in disease states are more difficult to perceive than differences in everyday objects. In the future, machine learning in radiology is expected to have a substantial clinical impact with imaging examinations being routinely obtained in clinical practice, providing an opportunity to improve decision support in medical image interpretation. The term of note is decision support, indicating that computers will augment human decision making, making it more effective and efficient. The clinical impact of having computers in the routine clinical practice may allow radiologists to further integrate their knowledge with their clinical colleagues in other medical specialties and allow for precision medicine. Copyright © 2018. Published by Elsevier Inc.

  1. Evaluation of the FIR Example using Xilinx Vivado High-Level Synthesis Compiler

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jin, Zheming; Finkel, Hal; Yoshii, Kazutomo

    Compared to central processing units (CPUs) and graphics processing units (GPUs), field programmable gate arrays (FPGAs) have major advantages in reconfigurability and performance achieved per watt. This development flow has been augmented with high-level synthesis (HLS) flow that can convert programs written in a high-level programming language to Hardware Description Language (HDL). Using high-level programming languages such as C, C++, and OpenCL for FPGA-based development could allow software developers, who have little FPGA knowledge, to take advantage of the FPGA-based application acceleration. This improves developer productivity and makes the FPGA-based acceleration accessible to hardware and software developers. Xilinx Vivado HLSmore » compiler is a high-level synthesis tool that enables C, C++ and System C specification to be directly targeted into Xilinx FPGAs without the need to create RTL manually. The white paper [1] published recently by Xilinx uses a finite impulse response (FIR) example to demonstrate the variable-precision features in the Vivado HLS compiler and the resource and power benefits of converting floating point to fixed point for a design. To get a better understanding of variable-precision features in terms of resource usage and performance, this report presents the experimental results of evaluating the FIR example using Vivado HLS 2017.1 and a Kintex Ultrascale FPGA. In addition, we evaluated the half-precision floating-point data type against the double-precision and single-precision data type and present the detailed results.« less

  2. Gravitation experiments at Stanford. [using general relativity theory

    NASA Technical Reports Server (NTRS)

    Lipa, J. A.

    1980-01-01

    The experimental situation in post-Newtonian gravitation is briefly reviewed in order to reexamine the extent to which experiment supports or refutes general relativity. A description is given of the equivalence principle project, the gyroscope experiment, and the search for gravity waves. It is noted that even though some doubt has been cast on the value of the perihelion advance and the gravitational redshift as precise tests of general relativity in the past few years, many competing theories have been ruled out; in particular, the results from the Viking mission significantly reduce the credibility of the Brans-Dicke theory (Brans and Dicke, 1961). The dimensionless constant omega in this theory is now forced to exceed 50, while the value originally proposed was 6 (omega being infinity in general relativity). It is noted that the gyro experiment described is capable of putting much tighter limits on this parameter, and together with the other experiments in progress will help place gravitational theory on a firmer experimental footing.

  3. Building an automated problem list based on natural language processing: lessons learned in the early phase of development.

    PubMed

    Solti, Imre; Aaronson, Barry; Fletcher, Grant; Solti, Magdolna; Gennari, John H; Cooper, Melissa; Payne, Tom

    2008-11-06

    Detailed problem lists that comply with JCAHO requirements are important components of electronic health records. Besides improving continuity of care electronic problem lists could serve as foundation infrastructure for clinical trial recruitment, research, biosurveillance and billing informatics modules. However, physicians rarely maintain problem lists. Our team is building a system using MetaMap and UMLS to automatically populate the problem list. We report our early results evaluating the application. Three physicians generated gold standard problem lists for 100 cardiology ambulatory progress notes. Our application had 88% sensitivity and 66% precision using a non-modified UMLS dataset. The systemâs misses concentrated in the group of ambiguous problem list entries (Chi-square=27.12 p<0.0001). In addition to the explicit entries, the notes included 10% implicit entry candidates. MetaMap and UMLS are readily applicable to automate the problem list. Ambiguity in medical documents has consequences for performance evaluation of automated systems.

  4. A Lane-Level LBS System for Vehicle Network with High-Precision BDS/GPS Positioning

    PubMed Central

    Guo, Chi; Guo, Wenfei; Cao, Guangyi; Dong, Hongbo

    2015-01-01

    In recent years, research on vehicle network location service has begun to focus on its intelligence and precision. The accuracy of space-time information has become a core factor for vehicle network systems in a mobile environment. However, difficulties persist in vehicle satellite positioning since deficiencies in the provision of high-quality space-time references greatly limit the development and application of vehicle networks. In this paper, we propose a high-precision-based vehicle network location service to solve this problem. The major components of this study include the following: (1) application of wide-area precise positioning technology to the vehicle network system. An adaptive correction message broadcast protocol is designed to satisfy the requirements for large-scale target precise positioning in the mobile Internet environment; (2) development of a concurrence service system with a flexible virtual expansion architecture to guarantee reliable data interaction between vehicles and the background; (3) verification of the positioning precision and service quality in the urban environment. Based on this high-precision positioning service platform, a lane-level location service is designed to solve a typical traffic safety problem. PMID:25755665

  5. Online access to doctors' notes: patient concerns about privacy.

    PubMed

    Vodicka, Elisabeth; Mejilla, Roanne; Leveille, Suzanne G; Ralston, James D; Darer, Jonathan D; Delbanco, Tom; Walker, Jan; Elmore, Joann G

    2013-09-26

    Offering patients online access to medical records, including doctors' visit notes, holds considerable potential to improve care. However, patients may worry about loss of privacy when accessing personal health information through Internet-based patient portals. The OpenNotes study provided patients at three US health care institutions with online access to their primary care doctors' notes and then collected survey data about their experiences, including their concerns about privacy before and after participation in the intervention. To identify patients' attitudes toward privacy when given electronic access to their medical records, including visit notes. The design used a nested cohort study of patients surveyed at baseline and after a 1-year period during which they were invited to read their visit notes through secure patient portals. Participants consisted of 3874 primary care patients from Beth Israel Deaconess Medical Center (Boston, MA), Geisinger Health System (Danville, PA), and Harborview Medical Center (Seattle, WA) who completed surveys before and after the OpenNotes intervention. The measures were patient-reported levels of concern regarding privacy associated with online access to visit notes. 32.91% of patients (1275/3874 respondents) reported concerns about privacy at baseline versus 36.63% (1419/3874 respondents) post-intervention. Baseline concerns were associated with non-white race/ethnicity and lower confidence in communicating with doctors, but were not associated with choosing to read notes or desire for continued online access post-intervention (nearly all patients with notes available chose to read them and wanted continued access). While the level of concern among most participants did not change during the intervention, 15.54% (602/3874 respondents, excluding participants who responded "don't know") reported more concern post-intervention, and 12.73% (493/3874 respondents, excluding participants who responded "don't know") reported less concern. When considering online access to visit notes, approximately one-third of patients had concerns about privacy at baseline and post-intervention. These perceptions did not deter participants from accessing their notes, suggesting that the benefits of online access to medical records may outweigh patients' perceived risks to privacy.

  6. Online Access to Doctors' Notes: Patient Concerns About Privacy

    PubMed Central

    Mejilla, Roanne; Leveille, Suzanne G; Ralston, James D; Darer, Jonathan D; Delbanco, Tom; Walker, Jan; Elmore, Joann G

    2013-01-01

    Background Offering patients online access to medical records, including doctors’ visit notes, holds considerable potential to improve care. However, patients may worry about loss of privacy when accessing personal health information through Internet-based patient portals. The OpenNotes study provided patients at three US health care institutions with online access to their primary care doctors’ notes and then collected survey data about their experiences, including their concerns about privacy before and after participation in the intervention. Objective To identify patients’ attitudes toward privacy when given electronic access to their medical records, including visit notes. Methods The design used a nested cohort study of patients surveyed at baseline and after a 1-year period during which they were invited to read their visit notes through secure patient portals. Participants consisted of 3874 primary care patients from Beth Israel Deaconess Medical Center (Boston, MA), Geisinger Health System (Danville, PA), and Harborview Medical Center (Seattle, WA) who completed surveys before and after the OpenNotes intervention. The measures were patient-reported levels of concern regarding privacy associated with online access to visit notes. Results 32.91% of patients (1275/3874 respondents) reported concerns about privacy at baseline versus 36.63% (1419/3874 respondents) post-intervention. Baseline concerns were associated with non-white race/ethnicity and lower confidence in communicating with doctors, but were not associated with choosing to read notes or desire for continued online access post-intervention (nearly all patients with notes available chose to read them and wanted continued access). While the level of concern among most participants did not change during the intervention, 15.54% (602/3874 respondents, excluding participants who responded “don’t know”) reported more concern post-intervention, and 12.73% (493/3874 respondents, excluding participants who responded “don’t know”) reported less concern. Conclusions When considering online access to visit notes, approximately one-third of patients had concerns about privacy at baseline and post-intervention. These perceptions did not deter participants from accessing their notes, suggesting that the benefits of online access to medical records may outweigh patients’ perceived risks to privacy. PMID:24072335

  7. Reliability and precision of pellet-group counts for estimating landscape-level deer density

    Treesearch

    David S. deCalesta

    2013-01-01

    This study provides hitherto unavailable methodology for reliably and precisely estimating deer density within forested landscapes, enabling quantitative rather than qualitative deer management. Reliability and precision of the deer pellet-group technique were evaluated in 1 small and 2 large forested landscapes. Density estimates, adjusted to reflect deer harvest and...

  8. A farm-level precision land management framework based on integer programming

    PubMed Central

    Li, Qi; Hu, Guiping; Jubery, Talukder Zaki; Ganapathysubramanian, Baskar

    2017-01-01

    Farmland management involves several planning and decision making tasks including seed selection and irrigation management. A farm-level precision farmland management model based on mixed integer linear programming is proposed in this study. Optimal decisions are designed for pre-season planning of crops and irrigation water allocation. The model captures the effect of size and shape of decision scale as well as special irrigation patterns. The authors illustrate the model with a case study on a farm in the state of California in the U.S. and show the model can capture the impact of precision farm management on profitability. The results show that threefold increase of annual net profit for farmers could be achieved by carefully choosing irrigation and seed selection. Although farmers could increase profits by applying precision management to seed or irrigation alone, profit increase is more significant if farmers apply precision management on seed and irrigation simultaneously. The proposed model can also serve as a risk analysis tool for farmers facing seasonal irrigation water limits as well as a quantitative tool to explore the impact of precision agriculture. PMID:28346499

  9. High Precision Prediction of Functional Sites in Protein Structures

    PubMed Central

    Buturovic, Ljubomir; Wong, Mike; Tang, Grace W.; Altman, Russ B.; Petkovic, Dragutin

    2014-01-01

    We address the problem of assigning biological function to solved protein structures. Computational tools play a critical role in identifying potential active sites and informing screening decisions for further lab analysis. A critical parameter in the practical application of computational methods is the precision, or positive predictive value. Precision measures the level of confidence the user should have in a particular computed functional assignment. Low precision annotations lead to futile laboratory investigations and waste scarce research resources. In this paper we describe an advanced version of the protein function annotation system FEATURE, which achieved 99% precision and average recall of 95% across 20 representative functional sites. The system uses a Support Vector Machine classifier operating on the microenvironment of physicochemical features around an amino acid. We also compared performance of our method with state-of-the-art sequence-level annotator Pfam in terms of precision, recall and localization. To our knowledge, no other functional site annotator has been rigorously evaluated against these key criteria. The software and predictive models are incorporated into the WebFEATURE service at http://feature.stanford.edu/wf4.0-beta. PMID:24632601

  10. Validity of a smartphone protractor to measure sagittal parameters in adult spinal deformity.

    PubMed

    Kunkle, William Aaron; Madden, Michael; Potts, Shannon; Fogelson, Jeremy; Hershman, Stuart

    2017-10-01

    Smartphones have become an integral tool in the daily life of health-care professionals (Franko 2011). Their ease of use and wide availability often make smartphones the first tool surgeons use to perform measurements. This technique has been validated for certain orthopedic pathologies (Shaw 2012; Quek 2014; Milanese 2014; Milani 2014), but never to assess sagittal parameters in adult spinal deformity (ASD). This study was designed to assess the validity, reproducibility, precision, and efficiency of using a smartphone protractor application to measure sagittal parameters commonly measured in ASD assessment and surgical planning. This study aimed to (1) determine the validity of smartphone protractor applications, (2) determine the intra- and interobserver reliability of smartphone protractor applications when used to measure sagittal parameters in ASD, (3) determine the efficiency of using a smartphone protractor application to measure sagittal parameters, and (4) elucidate whether a physician's level of experience impacts the reliability or validity of using a smartphone protractor application to measure sagittal parameters in ASD. An experimental validation study was carried out. Thirty standard 36″ standing lateral radiographs were examined. Three separate measurements were performed using a marker and protractor; then at a separate time point, three separate measurements were performed using a smartphone protractor application for all 30 radiographs. The first 10 radiographs were then re-measured two more times, for a total of three measurements from both the smartphone protractor and marker and protractor. The parameters included lumbar lordosis, pelvic incidence, and pelvic tilt. Three raters performed all measurements-a junior level orthopedic resident, a senior level orthopedic resident, and a fellowship-trained spinal deformity surgeon. All data, including the time to perform the measurements, were recorded, and statistical analysis was performed to determine intra- and interobserver reliability, as well as accuracy, efficiency, and precision. Statistical analysis using the intra- and interclass correlation coefficient was calculated using R (version 3.3.2, 2016) to determine the degree of intra- and interobserver reliability. High rates of intra- and interobserver reliability were observed between the junior resident, senior resident, and attending surgeon when using the smartphone protractor application as demonstrated by high inter- and intra-class correlation coefficients greater than 0.909 and 0.874 respectively. High rates of inter- and intraobserver reliability were also seen between the junior resident, senior resident, and attending surgeon when a marker and protractor were used as demonstrated by high inter- and intra-class correlation coefficients greater than 0.909 and 0.807 respectively. The lumbar lordosis, pelvic incidence, and pelvic tilt values were accurately measured by all three raters, with excellent inter- and intra-class correlation coefficient values. When the first 10 radiographs were re-measured at different time points, a high degree of precision was noted. Measurements performed using the smartphone application were consistently faster than using a marker and protractor-this difference reached statistical significance of p<.05. Adult spinal deformity radiographic parameters can be measured accurately, precisely, reliably, and more efficiently using a smartphone protractor application than with a standard protractor and wax pencil. A high degree of intra- and interobserver reliability was seen between the residents and attending surgeon, indicating measurements made with a smartphone protractor are unaffected by an observer's level of experience. As a result, smartphone protractors may be used when planning ASD surgery. Copyright © 2017 Elsevier Inc. All rights reserved.

  11. Effect of analytical conditions in wavelength dispersive electron microprobe analysis on the measurement of strontium-to-calcium (Sr/Ca) ratios in otoliths of anadromous salmonids

    USGS Publications Warehouse

    Zimmerman, Christian E.; Nielsen, Roger L.

    2003-01-01

    The use of strontium-to-calcium (Sr/Ca) ratios in otoliths is becoming a standard method to describe life history type and the chronology of migrations between freshwater and seawater habitats in teleosts (e.g. Kalish, 1990; Radtke et al., 1990; Secor, 1992; Rieman et al., 1994; Radtke, 1995; Limburg, 1995; Tzeng et al. 1997; Volk et al., 2000; Zimmerman, 2000; Zimmerman and Reeves, 2000, 2002). This method provides critical information concerning the relationship and ecology of species exhibiting phenotypic variation in migratory behavior (Kalish, 1990; Secor, 1999). Methods and procedures, however, vary among laboratories because a standard method or protocol for measurement of Sr in otoliths does not exist. In this note, we examine the variations in analytical conditions in an effort to increase precision of Sr/Ca measurements. From these findings we argue that precision can be maximized with higher beam current (although there is specimen damage) than previously recommended by Gunn et al. (1992).

  12. Note: A manifold ranking based saliency detection method for camera.

    PubMed

    Zhang, Libo; Sun, Yihan; Luo, Tiejian; Rahman, Mohammad Muntasir

    2016-09-01

    Research focused on salient object region in natural scenes has attracted a lot in computer vision and has widely been used in many applications like object detection and segmentation. However, an accurate focusing on the salient region, while taking photographs of the real-world scenery, is still a challenging task. In order to deal with the problem, this paper presents a novel approach based on human visual system, which works better with the usage of both background prior and compactness prior. In the proposed method, we eliminate the unsuitable boundary with a fixed threshold to optimize the image boundary selection which can provide more precise estimations. Then, the object detection, which is optimized with compactness prior, is obtained by ranking with background queries. Salient objects are generally grouped together into connected areas that have compact spatial distributions. The experimental results on three public datasets demonstrate that the precision and robustness of the proposed algorithm have been improved obviously.

  13. Suicide Note Sentiment Classification: A Supervised Approach Augmented by Web Data

    PubMed Central

    Xu, Yan; Wang, Yue; Liu, Jiahua; Tu, Zhuowen; Sun, Jian-Tao; Tsujii, Junichi; Chang, Eric

    2012-01-01

    Objective: To create a sentiment classification system for the Fifth i2b2/VA Challenge Track 2, which can identify thirteen subjective categories and two objective categories. Design: We developed a hybrid system using Support Vector Machine (SVM) classifiers with augmented training data from the Internet. Our system consists of three types of classification-based systems: the first system uses spanning n-gram features for subjective categories, the second one uses bag-of-n-gram features for objective categories, and the third one uses pattern matching for infrequent or subtle emotion categories. The spanning n-gram features are selected by a feature selection algorithm that leverages emotional corpus from weblogs. Special normalization of objective sentences is generalized with shallow parsing and external web knowledge. We utilize three sources of web data: the weblog of LiveJournal which helps to improve the feature selection, the eBay List which assists in special normalization of information and instructions categories, and the suicide project web which provides unlabeled data with similar properties as suicide notes. Measurements: The performance is evaluated by the overall micro-averaged precision, recall and F-measure. Result: Our system achieved an overall micro-averaged F-measure of 0.59. Happiness_peacefulness had the highest F-measure of 0.81. We were ranked as the second best out of 26 competing teams. Conclusion: Our results indicated that classifying fine-grained sentiments at sentence level is a non-trivial task. It is effective to divide categories into different groups according to their semantic properties. In addition, our system performance benefits from external knowledge extracted from publically available web data of other purposes; performance can be further enhanced when more training data is available. PMID:22879758

  14. 6. 2nd floor where stables used to be; note bottom ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    6. 2nd floor where stables used to be; note bottom of truss with suspension rods for floor which results in clear span on 1st level - Diebolt Brewing Company Stable, 2695 Pittsburgh Avenue, Cleveland, Cuyahoga County, OH

  15. Combining structured and unstructured data to identify a cohort of ICU patients who received dialysis

    PubMed Central

    Abhyankar, Swapna; Demner-Fushman, Dina; Callaghan, Fiona M; McDonald, Clement J

    2014-01-01

    Objective To develop a generalizable method for identifying patient cohorts from electronic health record (EHR) data—in this case, patients having dialysis—that uses simple information retrieval (IR) tools. Methods We used the coded data and clinical notes from the 24 506 adult patients in the Multiparameter Intelligent Monitoring in Intensive Care database to identify patients who had dialysis. We used SQL queries to search the procedure, diagnosis, and coded nursing observations tables based on ICD-9 and local codes. We used a domain-specific search engine to find clinical notes containing terms related to dialysis. We manually validated the available records for a 10% random sample of patients who potentially had dialysis and a random sample of 200 patients who were not identified as having dialysis based on any of the sources. Results We identified 1844 patients that potentially had dialysis: 1481 from the three coded sources and 1624 from the clinical notes. Precision for identifying dialysis patients based on available data was estimated to be 78.4% (95% CI 71.9% to 84.2%) and recall was 100% (95% CI 86% to 100%). Conclusions Combining structured EHR data with information from clinical notes using simple queries increases the utility of both types of data for cohort identification. Patients identified by more than one source are more likely to meet the inclusion criteria; however, including patients found in any of the sources increases recall. This method is attractive because it is available to researchers with access to EHR data and off-the-shelf IR tools. PMID:24384230

  16. High precision analytical description of the allowed β spectrum shape

    NASA Astrophysics Data System (ADS)

    Hayen, Leendert; Severijns, Nathal; Bodek, Kazimierz; Rozpedzik, Dagmara; Mougeot, Xavier

    2018-01-01

    A fully analytical description of the allowed β spectrum shape is given in view of ongoing and planned measurements. Its study forms an invaluable tool in the search for physics beyond the standard electroweak model and the weak magnetism recoil term. Contributions stemming from finite size corrections, mass effects, and radiative corrections are reviewed. Particular focus is placed on atomic and chemical effects, where the existing description is extended and analytically provided. The effects of QCD-induced recoil terms are discussed, and cross-checks were performed for different theoretical formalisms. Special attention was given to a comparison of the treatment of nuclear structure effects in different formalisms. Corrections were derived for both Fermi and Gamow-Teller transitions, and methods of analytical evaluation thoroughly discussed. In its integrated form, calculated f values were in agreement with the most precise numerical results within the aimed for precision. The need for an accurate evaluation of weak magnetism contributions was stressed, and the possible significance of the oft-neglected induced pseudoscalar interaction was noted. Together with improved atomic corrections, an analytical description was presented of the allowed β spectrum shape accurate to a few parts in 10-4 down to 1 keV for low to medium Z nuclei, thereby extending the work by previous authors by nearly an order of magnitude.

  17. Automatic scanning and measuring using POLLY

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fields, T.

    1993-07-01

    The HPD and PEPR automatic measuring systems, which have been described by B. Powell and I. Pless at this conference, were developed in the 1960`s to be used for what would now be called {open_quotes}batch processing.{close_quotes} That is, an entire reel of bubble chamber film containing interesting events whose tracks had been rough-digitized would be processed in an extended run by a dedicated computer/precision digitizer hardware system, with no human intervention. Then, at a later time, events for which the precision measurement did not appear to be successful would be handled with some type of {open_quotes}fixup{close_quotes} station or process. Bymore » contrast, the POLLY system included from the start, not only a computer and a precision CRT measuring device, but also a human operator who could have convenient two-way interactions with the computer and could also view the picture directly. Inclusion of a human as a key part of the system had some important beneficial effects, as has been described in the original papers. In this note the author summarizes those effects, and also points out connections between the POLLY system philosophy and subsequent developments in both high energy physics data analysis and computing systems.« less

  18. Technical note: Aerosol light absorption measurements with a carbon analyser - Calibration and precision estimates

    NASA Astrophysics Data System (ADS)

    Ammerlaan, B. A. J.; Holzinger, R.; Jedynska, A. D.; Henzing, J. S.

    2017-09-01

    Equivalent Black Carbon (EBC) and Elemental Carbon (EC) are different mass metrics to quantify the amount of combustion aerosol. Both metrics have their own measurement technique. In state-of-the-art carbon analysers, optical measurements are used to correct for organic carbon that is not evolving because of pyrolysis. These optical measurements are sometimes used to apply the technique of absorption photometers. Here, we use the transmission measurements of our carbon analyser for simultaneous determination of the elemental carbon concentration and the absorption coefficient. We use MAAP data from the CESAR observatory, the Netherlands, to correct for aerosol-filter interactions by linking the attenuation coefficient from the carbon analyser to the absorption coefficient measured by the MAAP. Application of the calibration to an independent data set of MAAP and OC/EC observations for the same location shows that the calibration is applicable to other observation periods. Because of simultaneous measurements of light absorption properties of the aerosol and elemental carbon, variation in the mass absorption efficiency (MAE) can be studied. We further show that the absorption coefficients and MAE in this set-up are determined within a precision of 10% and 12%, respectively. The precisions could be improved to 4% and 8% when the light transmission signal in the carbon analyser is very stable.

  19. OPEN DATA FOR DISCOVERY SCIENCE.

    PubMed

    Payne, Philip R O; Huang, Kun; Shah, Nigam H; Tenenbaum, Jessica

    2017-01-01

    The modern healthcare and life sciences ecosystem is moving towards an increasingly open and data-centric approach to discovery science. This evolving paradigm is predicated on a complex set of information needs related to our collective ability to share, discover, reuse, integrate, and analyze open biological, clinical, and population level data resources of varying composition, granularity, and syntactic or semantic consistency. Such an evolution is further impacted by a concomitant growth in the size of data sets that can and should be employed for both hypothesis discovery and testing. When such open data can be accessed and employed for discovery purposes, a broad spectrum of high impact end-points is made possible. These span the spectrum from identification of de novo biomarker complexes that can inform precision medicine, to the repositioning or repurposing of extant agents for new and cost-effective therapies, to the assessment of population level influences on disease and wellness. Of note, these types of uses of open data can be either primary, wherein open data is the substantive basis for inquiry, or secondary, wherein open data is used to augment or enrich project-specific or proprietary data that is not open in and of itself. This workshop is concerned with the key challenges, opportunities, and methodological best practices whereby open data can be used to drive the advancement of discovery science in all of the aforementioned capacities.

  20. Robot-Assisted Guitar Hero for Finger Rehabilitation after Stroke

    PubMed Central

    Taheri, Hossein; Rowe, Justin B.; Gardner, David; Chan, Vicky; Reinkensmeyer, David J.; Wolbrecht, Eric T.

    2014-01-01

    This paper describes the design and testing of a robotic device for finger therapy after stroke: FINGER (Finger Individuating Grasp Exercise Robot). FINGER makes use of stacked single degree-of-freedom mechanisms to assist subjects in moving individual fingers in a naturalistic grasping pattern through much of their full range of motion. The device has a high bandwidth of control (−3dB at approximately 8 Hz) and is backdriveable. These characteristics make it capable of assisting in grasping tasks that require precise timing. We therefore used FINGER to assist individuals with a stroke (n = 8) and without impairment (n = 4) in playing a game similar to Guitar Hero©. The subjects attempted to move their fingers to target positions at times specified by notes that were graphically streamed to popular music. We show here that by automatically adjusting the robot gains, it is possible to use FINGER to modulate the subject’s success rate at the game, across a range of impairment levels. Modulating success rates did not alter the stroke subject’s effort, although the unimpaired subjects exerted more force when they were made less successful. We also present a novel measure of finger individuation that can be assessed as individuals play Guitar Hero with FINGER. The results demonstrate the ability of FINGER to provide controlled levels of assistance during an engaging computer game, and to quantify finger individuation after stroke. PMID:23366783

  1. Deep learning approach for classifying, detecting and predicting photometric redshifts of quasars in the Sloan Digital Sky Survey stripe 82

    NASA Astrophysics Data System (ADS)

    Pasquet-Itam, J.; Pasquet, J.

    2018-04-01

    We have applied a convolutional neural network (CNN) to classify and detect quasars in the Sloan Digital Sky Survey Stripe 82 and also to predict the photometric redshifts of quasars. The network takes the variability of objects into account by converting light curves into images. The width of the images, noted w, corresponds to the five magnitudes ugriz and the height of the images, noted h, represents the date of the observation. The CNN provides good results since its precision is 0.988 for a recall of 0.90, compared to a precision of 0.985 for the same recall with a random forest classifier. Moreover 175 new quasar candidates are found with the CNN considering a fixed recall of 0.97. The combination of probabilities given by the CNN and the random forest makes good performance even better with a precision of 0.99 for a recall of 0.90. For the redshift predictions, the CNN presents excellent results which are higher than those obtained with a feature extraction step and different classifiers (a K-nearest-neighbors, a support vector machine, a random forest and a Gaussian process classifier). Indeed, the accuracy of the CNN within |Δz| < 0.1 can reach 78.09%, within |Δz| < 0.2 reaches 86.15%, within |Δz| < 0.3 reaches 91.2% and the value of root mean square (rms) is 0.359. The performance of the KNN decreases for the three |Δz| regions, since within the accuracy of |Δz| < 0.1, |Δz| < 0.2, and |Δz| < 0.3 is 73.72%, 82.46%, and 90.09% respectively, and the value of rms amounts to 0.395. So the CNN successfully reduces the dispersion and the catastrophic redshifts of quasars. This new method is very promising for the future of big databases such as the Large Synoptic Survey Telescope. A table of the candidates is only available at the CDS via anonymous ftp to http://cdsarc.u-strasbg.fr (http://130.79.128.5) or via http://cdsarc.u-strasbg.fr/viz-bin/qcat?J/A+A/611/A97

  2. High-energy Nd:glass laser for oncology

    NASA Astrophysics Data System (ADS)

    Boutchenkov, Vyatcheslav A.; Utenkov, Boris I.; Zaitsev, V. K.; Bayanov, Valentin I.; Serebryakov, Victor A.

    1991-07-01

    The use of high energy solid state lasers for the treatment of human skin neoplasia was based on the experiments and clinic studies by Helsper and Goldman (1964), McGuff (1966). The heat of precise local volume is emitted due to the pulse laser radiation. The thermal effect results in the superficial necrosis of tissues with their integrity destruction, vascular repture accompanied by bloodstoke in some cases and by capillary embolism in others. Obvious tumour destruction is note only in case of high density irradiation. General tumour destruction depends on biological neoplasia features as well as the laser type.

  3. On the Treatment of l-changing Proton-hydrogen Rydberg Atom Collisions

    NASA Astrophysics Data System (ADS)

    Vrinceanu, Daniel; Onofrio, Roberto; Sadeghpour, Hossein

    2018-01-01

    Energy-conserving, angular momentum-changing collisions between protons and highly excited Rydberg hydrogen atoms are important for precise understanding of the primordial recombination cascade, and the elemental abundance.Early approaches to l-changing collisions used perturbation theory for only dipole-allowed (Δl = ±1) transitions. An exact non-perturbative quantum mechanical treatment is possible, but it comes at computational cost for highly excited Rydberg states. In this note we show how to obtain a semi-classical limit that is accurate and simple, and develop further physical insights afforded by the non-perturbative quantum mechanical treatment.

  4. Note: Design and implementation of a home-built imaging system with low jitter for cold atom experiments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hachtel, A. J.; Gillette, M. C.; Clements, E. R.

    A novel home-built system for imaging cold atom samples is presented using a readily available astronomy camera which has the requisite sensitivity but no timing-control. We integrate the camera with LabVIEW achieving fast, low-jitter imaging with a convenient user-defined interface. We show that our system takes precisely timed millisecond exposures and offers significant improvements in terms of system jitter and readout time over previously reported home-built systems. Our system rivals current commercial “black box” systems in performance and user-friendliness.

  5. Note: Ultra-low birefringence dodecagonal vacuum glass cell

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brakhane, Stefan, E-mail: brakhane@iap.uni-bonn.de; Alt, Wolfgang; Meschede, Dieter

    We report on an ultra-low birefringence dodecagonal glass cell for ultra-high vacuum applications. The epoxy-bonded trapezoidal windows of the cell are made of SF57 glass, which exhibits a very low stress-induced birefringence. We characterize the birefringence Δn of each window with the cell under vacuum conditions, obtaining values around 10{sup −8}. After baking the cell at 150 °C, we reach a pressure below 10{sup −10} mbar. In addition, each window is antireflection coated on both sides, which is highly desirable for quantum optics experiments and precision measurements.

  6. Jane Austen on love and pedagogical power.

    PubMed

    Fessenbecker, Patrick

    2011-01-01

    This essay notes initially recent prominence of theories of pedagogy that attempt to "de-mystify" it and reveal troubling power relations, and their subsequent contention that love is impossible in the student-teacher relationship. "Pedagogical" interpretations of Jane Austen's fiction, however, see pedagogy as essential to love. I argue that this is so precisely because of the power dynamics involved; drawing on Jessica Benjamin's psychoanalytic interpretation of G. W. F. Hegel's analysis of the "Lord-Bondsman," I suggest that Austen portrays the loving relationship as inherently involving the occupation and subsequent exchange of roles as superior and inferior, incarnated as "teacher" and "student."

  7. 1. Credit WCT. Original 2 1/4" x 2 1/4" color ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    1. Credit WCT. Original 2- 1/4" x 2- 1/4" color negative is housed in the JPL Photography Laboratory, Pasadena, California. Photo shows John Morrow in charge of milling operations on coupons ("dogbones") of propellant on an Index milling machine. Coupons were milled to precise dimensions for tensile tests. Note that two sprinkler heads have been placed in very close proximity to the milling table for fire suppression purposes (JPL negative no. JPL-10283AC, 27 January 1989) - Jet Propulsion Laboratory Edwards Facility, Preparation Building, Edwards Air Force Base, Boron, Kern County, CA

  8. Note: Automated electrochemical etching and polishing of silver scanning tunneling microscope tips.

    PubMed

    Sasaki, Stephen S; Perdue, Shawn M; Rodriguez Perez, Alejandro; Tallarida, Nicholas; Majors, Julia H; Apkarian, V Ara; Lee, Joonhee

    2013-09-01

    Fabrication of sharp and smooth Ag tips is crucial in optical scanning probe microscope experiments. To ensure reproducible tip profiles, the polishing process is fully automated using a closed-loop laminar flow system to deliver the electrolytic solution to moving electrodes mounted on a motorized translational stage. The repetitive translational motion is controlled precisely on the μm scale with a stepper motor and screw-thread mechanism. The automated setup allows reproducible control over the tip profile and improves smoothness and sharpness of tips (radius 27 ± 18 nm), as measured by ultrafast field emission.

  9. Exercise Prescription for Physical Fitness.

    ERIC Educational Resources Information Center

    Pollock, Michael L.; And Others

    1995-01-01

    Examines current guidelines for physical fitness, noting issues that may influence the updating of the American College of Sports Medicine exercise statement. Differences between exercise prescription for fitness and physical activity for health are discussed, noting the importance of designing individualized programs with appropriate levels of…

  10. Assessment of fatigue in rheumatoid arthritis: a psychometric comparison of single-item, multiitem, and multidimensional measures.

    PubMed

    Oude Voshaar, Martijn A H; Ten Klooster, Peter M; Bode, Christina; Vonkeman, Harald E; Glas, Cees A W; Jansen, Tim; van Albada-Kuipers, Iet; van Riel, Piet L C M; van de Laar, Mart A F J

    2015-03-01

    To compare the psychometric functioning of multidimensional disease-specific, multiitem generic, and single-item measures of fatigue in patients with rheumatoid arthritis (RA). Confirmatory factor analysis (CFA) and longitudinal item response theory (IRT) modeling were used to evaluate the measurement structure and local reliability of the Bristol RA Fatigue Multi-Dimensional Questionnaire (BRAF-MDQ), the Medical Outcomes Study Short Form-36 (SF-36) vitality scale, and the BRAF Numerical Rating Scales (BRAF-NRS) in a sample of 588 patients with RA. A 1-factor CFA model yielded a similar fit to a 5-factor model with subscale-specific dimensions, and the items from the different instruments adequately fit the IRT model, suggesting essential unidimensionality in measurement. The SF-36 vitality scale outperformed the BRAF-MDQ at lower levels of fatigue, but was less precise at moderate to higher levels of fatigue. At these levels of fatigue, the living, cognition, and emotion subscales of the BRAF-MDQ provide additional precision. The BRAF-NRS showed a limited measurement range with its highest precision centered on average levels of fatigue. The different instruments appear to access a common underlying domain of fatigue severity, but differ considerably in their measurement precision along the continuum. The SF-36 vitality scale can be used to measure fatigue severity in samples with relatively mild fatigue. For samples expected to have higher levels of fatigue, the multidimensional BRAF-MDQ appears to be a better choice. The BRAF-NRS are not recommended if precise assessment is required, for instance in longitudinal settings.

  11. Corticobulbar fibres in the North American opossum (Didelphis marsupialis virginiana) with notes on the Tasmanian brust-tailed possum (Trichosurus vulpecula) and other marsupials.

    PubMed Central

    Martin, G F; Bresnahan, J C; Henkel, C K; Megirian, D

    1975-01-01

    Corticobulbar projections have been studied in the American opossum by both degeneration and autoradiographic methods and, for the most part, the results confirm our earlier observations (Martin & West, 1967; Martin, 1968). However, we have obtained evidence for certain connexions not previously described and have delineated the origin(s) of several connexions more precisely by paying particular attention to the degeneration present at thalamic levels in all cases and by the use of autoradiography. When our results are collated and correlated with new somatosensory cortical maps arrived at by microelectrode techniques (Pubols et al. 1975), it is obvious that corticolbulbar connexions in the North American opossum are remarkably similar to those in the monkey and differ mainly in quantity, relative origins and distribution and in the fact that some of them arise from spatially co-extensive motor-sensory areas (Lende, 1963a, b). In the light of our findings on the American opossum we have examined a large collection of brush-tailed possum material (as well as some from the potoroo and Tasmanian native cat) and have been able to extend our previous findings (Martin et al. 1971; Martin & Megirian, 1972) to a more precise evaluation of the origin of projections from the limb, face motor-sensory cortex. Differences between these representatives of the marsupial radiation, as well as features which are common to all, are described. Images Fig. 1 Fig. 2 Fig. 23 Fig. 24 Fig. 25 Fig. 26 Fig. 27 Fig. 28 Fig. 29 Fig. 30 Fig. 31 Fig. 32 Fig. 33 Fig. 34 Fig. 35 Fig. 36 Fig. 37 Fig. 38 PMID:1213949

  12. A cadaver study of mastoidectomy using an image‐guided human–robot collaborative control system

    PubMed Central

    Yoo, Myung Hoon; Lee, Hwan Seo; Yang, Chan Joo; Lee, Seung Hwan; Lim, Hoon; Lee, Seongpung

    2017-01-01

    Objective Surgical precision would be better achieved with the development of an anatomical monitoring and controlling robot system than by traditional surgery techniques alone. We evaluated the feasibility of robot‐assisted mastoidectomy in terms of duration, precision, and safety. Study Design Human cadaveric study. Materials and Methods We developed a multi‐degree‐of‐freedom robot system for a surgical drill with a balancing arm. The drill system is manipulated by the surgeon, the motion of the drill burr is monitored by the image‐guided system, and the brake is controlled by the robotic system. The system also includes an alarm as well as the brake to help avoid unexpected damage to vital structures. Experimental mastoidectomy was performed in 11 temporal bones of six cadavers. Parameters including duration and safety were assessed, as well as intraoperative damage, which was judged via pre‐ and post‐operative computed tomography. Results The duration of mastoidectomy in our study was comparable with that required for chronic otitis media patients. Although minor damage, such as dura exposure without tearing, was noted, no critical damage to the facial nerve or other important structures was observed. When the brake system was set to 1 mm from the facial nerve, the postoperative average bone thicknesses of the facial nerve was 1.39, 1.41, 1.22, 1.41, and 1.55 mm in the lateral, posterior pyramidal and anterior, lateral, and posterior mastoid portions, respectively. Conclusion Mastoidectomy can be successfully performed using our robot‐assisted system while maintaining a pre‐set limit of 1 mm in most cases. This system may thus be useful for more inexperienced surgeons. Level of Evidence NA. PMID:29094065

  13. Quantum preservation of the measurements precision using ultra-short strong pulses in exact analytical solution

    NASA Astrophysics Data System (ADS)

    Berrada, K.; Eleuch, H.

    2017-09-01

    Various schemes have been proposed to improve the parameter-estimation precision. In the present work, we suggest an alternative method to preserve the estimation precision by considering a model that closely describes a realistic experimental scenario. We explore this active way to control and enhance the measurements precision for a two-level quantum system interacting with classical electromagnetic field using ultra-short strong pulses with an exact analytical solution, i.e. beyond the rotating wave approximation. In particular, we investigate the variation of the precision with a few cycles pulse and a smooth phase jump over a finite time interval. We show that by acting on the shape of the phase transient and other parameters of the considered system, the amount of information may be increased and has smaller decay rate in the long time. These features make two-level systems incorporated in ultra-short, of-resonant and gradually changing phase good candidates for implementation of schemes for the quantum computation and the coherent information processing.

  14. Inter-observer agreement of a multi-parameter campsite monitoring program on the Dixie National Forest, Utah

    Treesearch

    Nicholas J. Glidden; Martha E. Lee

    2007-01-01

    Precision is crucial to campsite monitoring programs. Yet, little empirical research has ever been published on the level of precision of this type of monitoring programs. The purpose of this study was to evaluate the level of agreement between observers of campsite impacts using a multi-parameter campsite monitoring program. Thirteen trained observers assessed 16...

  15. Classification of LIDAR Data for Generating a High-Precision Roadway Map

    NASA Astrophysics Data System (ADS)

    Jeong, J.; Lee, I.

    2016-06-01

    Generating of a highly precise map grows up with development of autonomous driving vehicles. The highly precise map includes a precision of centimetres level unlike an existing commercial map with the precision of meters level. It is important to understand road environments and make a decision for autonomous driving since a robust localization is one of the critical challenges for the autonomous driving car. The one of source data is from a Lidar because it provides highly dense point cloud data with three dimensional position, intensities and ranges from the sensor to target. In this paper, we focus on how to segment point cloud data from a Lidar on a vehicle and classify objects on the road for the highly precise map. In particular, we propose the combination with a feature descriptor and a classification algorithm in machine learning. Objects can be distinguish by geometrical features based on a surface normal of each point. To achieve correct classification using limited point cloud data sets, a Support Vector Machine algorithm in machine learning are used. Final step is to evaluate accuracies of obtained results by comparing them to reference data The results show sufficient accuracy and it will be utilized to generate a highly precise road map.

  16. Corticospinal control of the thumb-index grip depends on precision of force control: a transcranial magnetic stimulation and functional magnetic resonance imagery study in humans.

    PubMed

    Bonnard, M; Galléa, C; De Graaf, J B; Pailhous, J

    2007-02-01

    The corticospinal system (CS) is well known to be of major importance for controlling the thumb-index grip, in particular for force grading. However, for a given force level, the way in which the involvement of this system could vary with increasing demands on precise force control is not well-known. Using transcranial magnetic stimulation and functional magnetic resonance imagery, the present experiments investigated whether increasing the precision demands while keeping the averaged force level similar during an isometric dynamic low-force control task, involving the thumb-index grip, does affect the corticospinal excitability to the thumb-index muscles and the activation of the motor cortices, primary and non-primary (supplementary motor area, dorsal and ventral premotor and in the contralateral area), at the origin of the CS. With transcranial magnetic stimulation, we showed that, when precision demands increased, the CS excitability increased to either the first dorsal interosseus or the opponens pollicis, and never to both, for similar ongoing electromyographic activation patterns of these muscles. With functional magnetic resonance imagery, we demonstrated that, for the same averaged force level, the amplitude of blood oxygen level-dependent signal increased in relation to the precision demands in the hand area of the contralateral primary motor cortex in the contralateral supplementary motor area, ventral and dorsal premotor area. Together these results show that, during the course of force generation, the CS integrates online top-down information to precisely fit the motor output to the task's constraints and that its multiple cortical origins are involved in this process, with the ventral premotor area appearing to have a special role.

  17. Study on mechanism of amplitude fluctuation of dual-frequency beat in microchip Nd:YAG laser

    NASA Astrophysics Data System (ADS)

    Chen, Hao; Tan, Yidong; Zhang, Shulian; Sun, Liqun

    2017-01-01

    In the laser heterodyne interferometry based on the microchip Nd:YAG dual-frequency laser, the amplitude of the beat note periodically fluctuates in time domain, which leads to the instability of the measurement. On the frequency spectrums of the two mono-frequency components of the laser and their beat note, several weak sideband signals are observed on both sides of the beat note. It is proved that the sideband frequencies are associated with the relaxation oscillation frequencies of the laser. The mechanism for the relaxation oscillations inducing the occurrence of the sideband signals is theoretically analyzed, and the quantitative relationship between the intensity ratio of the beat note to the sideband signal and the level of the amplitude fluctuation is simulated with the derived mathematical model. The results demonstrate that the periodical amplitude fluctuation of the beat note is actually induced by the relaxation oscillation. And the level of the amplitude fluctuation is lower than 10% when the intensity ratio is greater than 32 dB. These conclusions are beneficial to reduce the amplitude fluctuation of the microchip Nd:YAG dual-frequency laser and improve the stability of the heterodyne interferometry.

  18. 54. View from ground level in building no. 105 showing ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    54. View from ground level in building no. 105 showing lower radar scanner switch at open port door. Note incoming waveguide and control switch at lower left of photograph and note several waveguides leaving top of scanner switch around the circumference of switch. - Clear Air Force Station, Ballistic Missile Early Warning System Site II, One mile west of mile marker 293.5 on Parks Highway, 5 miles southwest of Anderson, Anderson, Denali Borough, AK

  19. Neuromuscular control of the head in an isometric force reproduction task: comparison of whiplash subjects and healthy controls.

    PubMed

    Descarreaux, Martin; Mayrand, Nancy; Raymond, Jean

    2007-01-01

    A number of recent scientific publications suggest that patients suffering from whiplash-associated disorders (WADs) exhibit sensorimotor deficits in the control of head and neck movements. The main objective of the present study was to evaluate if subjects with WADs can produce isometric neck extension and flexion forces with precision, variability, and a mode of control similar to the values of healthy subjects. A control group study with repeated measures. Neck force production parameters and neuromuscular control were measured in 17 whiplash and 14 control subjects. The experimental group included subjects who had a history of persistent neck pain or disability after a motor vehicle accident. Pain levels were assessed on a standard 100-mm visual analog pain scale at the beginning and end of the experiment. Each whiplash subject completed the neck disability index and the short-form 36 health survey (SF-36) questionnaire before the experiment. All subjects were asked to exert flexion and extension forces against a fixed head harness. Kinetic variables included time to peak force, time to peak force variability, peak force variability, and absolute error in peak force. Surface electrodes were applied bilaterally over the sternocleidomastoideus and paraspinal muscles. Electromyography (EMG)-dependent variables included EMG burst duration and amplitude using numerical integrated techniques. The average time to peak force was significantly longer for whiplash subjects than for the healthy controls. A significant increase in peak force variability was also observed in the whiplash group, and no group differences were noted for absolute error. Heightened muscular activity was seen in both paraspinal muscles, even though it only reached statistical significance for the left paraspinal muscle. Our results show that the whiplash subjects involved in the study were able to produce isometric forces with spatial precision similar to healthy controls using a motor strategy in which the time to peak force is increased. This trade-off between spatial precision and time to peak force probably reflects an adaptation aimed at limiting pain and further injuries.

  20. Experimental evaluation of active-member control of precision structures

    NASA Technical Reports Server (NTRS)

    Fanson, James; Blackwood, Gary; Chu, Cheng-Chih

    1989-01-01

    The results of closed loop experiments that use piezoelectric active-members to control the flexible motion of a precision truss structure are described. These experiments are directed toward the development of high-performance structural systems as part of the Control/Structure Interaction (CSI) program at JPL. The focus of CSI activity at JPL is to develop the technology necessary to accurately control both the shape and vibration levels in the precision structures from which proposed large space-based observatories will be built. Structural error budgets for these types of structures will likely be in the sub-micron regime; optical tolerances will be even tighter. In order to achieve system level stability and local positioning at this level, it is generally expected that some form of active control will be required.

  1. Precision Medicine and the Changing Landscape of Research Ethics.

    PubMed

    Hammer, Marilyn J

    2016-03-01

    President Barack Obama announced the launch of the National Institutes of Health Precision Medicine Initiative® (PMI) in January 2015. Precision medicine includes the concept of individualized or personalized medicine at a more exact level through advances in science and technology, such as genetics and genomics sequencing. Although many disease processes will be investigated through the precision medicine lens for greater understanding and improved treatment responses, oncology research and translation to practice is leading the initiative's debut, referred to as the near-term focus.

  2. Prolonged weightlessness effect on postflight plasma thyroid hormones

    NASA Technical Reports Server (NTRS)

    Leach, C. S.; Johnson, P. C.; Driscoll, T. B.

    1977-01-01

    Blood drawn before and after spaceflight from the nine Skylab astronauts showed a statistically significant increase in mean plasma thyroxine (T-4) of 1.4 micro g/dl and in thyroid-stimulating hormone (TSH) of 4 microunits ml. Concurrent triiodothyronine (T-3) levels decreased 27 ng/dl indicating inhibited conversion of T-4 to T-3. The T-3 decrease is postulated to be a result of the increased cortisol levels noted during and following each mission. These results confirm the thyroidal changes noted after the shorter Apollo flights and show that thyroid hormone levels change during spaceflight.

  3. Functioning information in the learning health system.

    PubMed

    Stucki, Gerold; Bickenbach, Jerome

    2017-02-01

    In this methodological note on applying the ICF in rehabilitation, we introduce functioning information as fundamental for the "learning health system" and the continuous improvement of the health system's response to people's functioning needs by means of the provision of rehabilitation. A learning health system for rehabilitation operates at the micro-level of the individual patient, meso-level of operational management, and the macro-level of policy that guides rehabilitation programming. All three levels rely on the capacity of the informational system of the health system for standardized documentation and coding of functioning information, and the development of national rehabilitation quality management systems. This methodological note describes how functioning information is used for the continuous improvement of functioning outcomes in a learning health system across these three levels.

  4. Spatial Distribution and Sampling Plans With Fixed Level of Precision for Citrus Aphids (Hom., Aphididae) on Two Orange Species.

    PubMed

    Kafeshani, Farzaneh Alizadeh; Rajabpour, Ali; Aghajanzadeh, Sirous; Gholamian, Esmaeil; Farkhari, Mohammad

    2018-04-02

    Aphis spiraecola Patch, Aphis gossypii Glover, and Toxoptera aurantii Boyer de Fonscolombe are three important aphid pests of citrus orchards. In this study, spatial distributions of the aphids on two orange species, Satsuma mandarin and Thomson navel, were evaluated using Taylor's power law and Iwao's patchiness. In addition, a fixed-precision sequential sampling plant was developed for each species on the host plant by Green's model at precision levels of 0.25 and 0.1. The results revealed that spatial distribution parameters and therefore the sampling plan were significantly different according to aphid and host plant species. Taylor's power law provides a better fit for the data than Iwao's patchiness regression. Except T. aurantii on Thomson navel orange, spatial distribution patterns of the aphids were aggregative on both citrus. T. aurantii had regular dispersion pattern on Thomson navel orange. Optimum sample size of the aphids varied from 30-2061 and 1-1622 shoots on Satsuma mandarin and Thomson navel orange based on aphid species and desired precision level. Calculated stop lines of the aphid species on Satsuma mandarin and Thomson navel orange ranged from 0.48 to 19 and 0.19 to 80.4 aphids per 24 shoots according to aphid species and desired precision level. The performance of the sampling plan was validated by resampling analysis using resampling for validation of sampling plans (RVSP) software. This sampling program is useful for IPM program of the aphids in citrus orchards.

  5. Evaluating the MEDLINE Core Clinical Journals filter: data-driven evidence assessing clinical utility.

    PubMed

    Klein-Fedyshin, Michele; Ketchum, Andrea M; Arnold, Robert M; Fedyshin, Peter J

    2014-12-01

    MEDLINE offers the Core Clinical Journals filter to limit to clinically useful journals. To determine its effectiveness for searching and patient-centric decision making, this study compared literature used for Morning Report in Internal Medicine with journals in the filter. An EndNote library with references answering 327 patient-related questions during Morning Report from 2007 to 2012 was exported to a file listing variables including designated Core Clinical Journal, Impact Factor, date used and medical subject. Bradford's law of scattering was applied ranking the journals and reflecting their clinical utility. Recall (sensitivity) and precision of the Core Morning Report journals and non-Core set was calculated. This study applied bibliometrics to compare the 628 articles used against these criteria to determine journals impacting decision making. Analysis shows 30% of clinically used articles are from the Core Clinical Journals filter and 16% of the journals represented are Core titles. When Bradford-ranked, 55% of the top 20 journals are Core. Articles <5 years old furnish 63% of sources used. Among the 63 Morning Report subjects, 55 have <50% precision and 41 have <50% recall including 37 subjects with 0% precision and 0% recall. Low usage of publications within the Core Clinical Journals filter indicates less relevance for hospital-based care. The divergence from high-impact medicine titles suggests clinically valuable journals differ from academically important titles. With few subjects demonstrating high recall or precision, the MEDLINE Core Clinical Journals filter may require a review and update to better align with current clinical needs. © 2014 John Wiley & Sons, Ltd.

  6. Validation of a Natural Language Processing Algorithm for Detecting Infectious Disease Symptoms in Primary Care Electronic Medical Records in Singapore.

    PubMed

    Hardjojo, Antony; Gunachandran, Arunan; Pang, Long; Abdullah, Mohammed Ridzwan Bin; Wah, Win; Chong, Joash Wen Chen; Goh, Ee Hui; Teo, Sok Huang; Lim, Gilbert; Lee, Mong Li; Hsu, Wynne; Lee, Vernon; Chen, Mark I-Cheng; Wong, Franco; Phang, Jonathan Siung King

    2018-06-11

    Free-text clinical records provide a source of information that complements traditional disease surveillance. To electronically harness these records, they need to be transformed into codified fields by natural language processing algorithms. The aim of this study was to develop, train, and validate Clinical History Extractor for Syndromic Surveillance (CHESS), an natural language processing algorithm to extract clinical information from free-text primary care records. CHESS is a keyword-based natural language processing algorithm to extract 48 signs and symptoms suggesting respiratory infections, gastrointestinal infections, constitutional, as well as other signs and symptoms potentially associated with infectious diseases. The algorithm also captured the assertion status (affirmed, negated, or suspected) and symptom duration. Electronic medical records from the National Healthcare Group Polyclinics, a major public sector primary care provider in Singapore, were randomly extracted and manually reviewed by 2 human reviewers, with a third reviewer as the adjudicator. The algorithm was evaluated based on 1680 notes against the human-coded result as the reference standard, with half of the data used for training and the other half for validation. The symptoms most commonly present within the 1680 clinical records at the episode level were those typically present in respiratory infections such as cough (744/7703, 9.66%), sore throat (591/7703, 7.67%), rhinorrhea (552/7703, 7.17%), and fever (928/7703, 12.04%). At the episode level, CHESS had an overall performance of 96.7% precision and 97.6% recall on the training dataset and 96.0% precision and 93.1% recall on the validation dataset. Symptoms suggesting respiratory and gastrointestinal infections were all detected with more than 90% precision and recall. CHESS correctly assigned the assertion status in 97.3%, 97.9%, and 89.8% of affirmed, negated, and suspected signs and symptoms, respectively (97.6% overall accuracy). Symptom episode duration was correctly identified in 81.2% of records with known duration status. We have developed an natural language processing algorithm dubbed CHESS that achieves good performance in extracting signs and symptoms from primary care free-text clinical records. In addition to the presence of symptoms, our algorithm can also accurately distinguish affirmed, negated, and suspected assertion statuses and extract symptom durations. ©Antony Hardjojo, Arunan Gunachandran, Long Pang, Mohammed Ridzwan Bin Abdullah, Win Wah, Joash Wen Chen Chong, Ee Hui Goh, Sok Huang Teo, Gilbert Lim, Mong Li Lee, Wynne Hsu, Vernon Lee, Mark I-Cheng Chen, Franco Wong, Jonathan Siung King Phang. Originally published in JMIR Medical Informatics (http://medinform.jmir.org), 11.06.2018.

  7. High level continuity for coordinate generation with precise controls

    NASA Technical Reports Server (NTRS)

    Eiseman, P. R.

    1982-01-01

    Coordinate generation techniques with precise local controls have been derived and analyzed for continuity requirements up to both the first and second derivatives, and have been projected to higher level continuity requirements from the established pattern. The desired local control precision was obtained when a family of coordinate surfaces could be uniformly distributed without a consequent creation of flat spots on the coordinate curves transverse to the family. Relative to the uniform distribution, the family could be redistributed from an a priori distribution function or from a solution adaptive approach, both without distortion from the underlying transformation which may be independently chosen to fit a nontrivial geometry and topology.

  8. [Precision nutrition in the era of precision medicine].

    PubMed

    Chen, P Z; Wang, H

    2016-12-06

    Precision medicine has been increasingly incorporated into clinical practice and is enabling a new era for disease prevention and treatment. As an important constituent of precision medicine, precision nutrition has also been drawing more attention during physical examinations. The main aim of precision nutrition is to provide safe and efficient intervention methods for disease treatment and management, through fully considering the genetics, lifestyle (dietary, exercise and lifestyle choices), metabolic status, gut microbiota and physiological status (nutrient level and disease status) of individuals. Three major components should be considered in precision nutrition, including individual criteria for sufficient nutritional status, biomarker monitoring or techniques for nutrient detection and the applicable therapeutic or intervention methods. It was suggested that, in clinical practice, many inherited and chronic metabolic diseases might be prevented or managed through precision nutritional intervention. For generally healthy populations, because lifestyles, dietary factors, genetic factors and environmental exposures vary among individuals, precision nutrition is warranted to improve their physical activity and reduce disease risks. In summary, research and practice is leading toward precision nutrition becoming an integral constituent of clinical nutrition and disease prevention in the era of precision medicine.

  9. Improved de-identification of physician notes through integrative modeling of both public and private medical text

    PubMed Central

    2013-01-01

    Background Physician notes routinely recorded during patient care represent a vast and underutilized resource for human disease studies on a population scale. Their use in research is primarily limited by the need to separate confidential patient information from clinical annotations, a process that is resource-intensive when performed manually. This study seeks to create an automated method for de-identifying physician notes that does not require large amounts of private information: in addition to training a model to recognize Protected Health Information (PHI) within private physician notes, we reverse the problem and train a model to recognize non-PHI words and phrases that appear in public medical texts. Methods Public and private medical text sources were analyzed to distinguish common medical words and phrases from Protected Health Information. Patient identifiers are generally nouns and numbers that appear infrequently in medical literature. To quantify this relationship, term frequencies and part of speech tags were compared between journal publications and physician notes. Standard medical concepts and phrases were then examined across ten medical dictionaries. Lists and rules were included from the US census database and previously published studies. In total, 28 features were used to train decision tree classifiers. Results The model successfully recalled 98% of PHI tokens from 220 discharge summaries. Cost sensitive classification was used to weight recall over precision (98% F10 score, 76% F1 score). More than half of the false negatives were the word “of” appearing in a hospital name. All patient names, phone numbers, and home addresses were at least partially redacted. Medical concepts such as “elevated white blood cell count” were informative for de-identification. The results exceed the previously approved criteria established by four Institutional Review Boards. Conclusions The results indicate that distributional differences between private and public medical text can be used to accurately classify PHI. The data and algorithms reported here are made freely available for evaluation and improvement. PMID:24083569

  10. Improved de-identification of physician notes through integrative modeling of both public and private medical text.

    PubMed

    McMurry, Andrew J; Fitch, Britt; Savova, Guergana; Kohane, Isaac S; Reis, Ben Y

    2013-10-02

    Physician notes routinely recorded during patient care represent a vast and underutilized resource for human disease studies on a population scale. Their use in research is primarily limited by the need to separate confidential patient information from clinical annotations, a process that is resource-intensive when performed manually. This study seeks to create an automated method for de-identifying physician notes that does not require large amounts of private information: in addition to training a model to recognize Protected Health Information (PHI) within private physician notes, we reverse the problem and train a model to recognize non-PHI words and phrases that appear in public medical texts. Public and private medical text sources were analyzed to distinguish common medical words and phrases from Protected Health Information. Patient identifiers are generally nouns and numbers that appear infrequently in medical literature. To quantify this relationship, term frequencies and part of speech tags were compared between journal publications and physician notes. Standard medical concepts and phrases were then examined across ten medical dictionaries. Lists and rules were included from the US census database and previously published studies. In total, 28 features were used to train decision tree classifiers. The model successfully recalled 98% of PHI tokens from 220 discharge summaries. Cost sensitive classification was used to weight recall over precision (98% F10 score, 76% F1 score). More than half of the false negatives were the word "of" appearing in a hospital name. All patient names, phone numbers, and home addresses were at least partially redacted. Medical concepts such as "elevated white blood cell count" were informative for de-identification. The results exceed the previously approved criteria established by four Institutional Review Boards. The results indicate that distributional differences between private and public medical text can be used to accurately classify PHI. The data and algorithms reported here are made freely available for evaluation and improvement.

  11. Surgical Instrument Decontamination Unit

    DTIC Science & Technology

    1989-02-15

    0.54 Aspergillus niger 8.55 1.32 Candida parapsilosa 18.30 3.44 note 1: As reported by Turner, 1975. note 2: Contamination level = 7x105 organisms...Serrat’a marcescens and two of the fungi. Although Aspergillus nrger andCandida parapsilosis were more resistant, lenses were completely disinfected

  12. Apathy and Reduced Speed of Processing Underlie Decline in Verbal Fluency following DBS.

    PubMed

    Foley, Jennifer A; Foltynie, Tom; Zrinzo, Ludvic; Hyam, Jonathan A; Limousin, Patricia; Cipolotti, Lisa

    2017-01-01

    Objective . Reduced verbal fluency is a strikingly uniform finding following deep brain stimulation (DBS) for Parkinson's disease (PD). The precise cognitive mechanism underlying this reduction remains unclear, but theories have suggested reduced motivation, linguistic skill, and/or executive function. It is of note, however, that previous reports have failed to consider the potential role of any changes in speed of processing. Thus, the aim of this study was to examine verbal fluency changes with a particular focus on the role of cognitive speed. Method . In this study, 28 patients with PD completed measures of verbal fluency, motivation, language, executive functioning, and speed of processing, before and after DBS. Results . As expected, there was a marked decline in verbal fluency but also in a timed test of executive functions and two measures of speed of processing. Verbal fluency decline was associated with markers of linguistic and executive functioning, but not after speed of processing was statistically controlled for. In contrast, greater decline in verbal fluency was associated with higher levels of apathy at baseline, which was not associated with changes in cognitive speed. Discussion . Reduced generativity and processing speed may account for the marked reduction in verbal fluency commonly observed following DBS.

  13. A case of an infant with congenital combined pituitary hormone deficiency and normalized liver histology of infantile cholestasis after hormone replacement therapy.

    PubMed

    Wada, Keisuke; Kobayashi, Hironori; Moriyama, Aisa; Haneda, Yasuhiro; Mushimoto, Yuichi; Hasegawa, Yuki; Onigata, Kazumichi; Kumori, Koji; Ishikawa, Noriyoshi; Maruyama, Riruke; Sogo, Tsuyoshi; Murphy, Lynne; Taketani, Takeshi

    2017-01-01

    Congenital combined pituitary hormone deficiency (CPHD) may present with cholestasis in the neonate or during early infancy. However, its precise mechanism is unknown. A 3-mo-old boy presented with cryptorchidism and hypoplastic scrotum after birth. Neonatal jaundice was noted but temporarily improved with phototherapy. Jaundice recurred at 2 mo of age. Elevated direct bilirubin (D-Bil) and liver dysfunction were found but cholangiography showed no signs of biliary atresia (BA). Liver biopsy findings showed giant cell formation of hepatocytes with hypoplastic bile ducts. Subsequent magnetic resonance imaging (MRI) of the head revealed a hypoplastic pituitary gland with an ectopic posterior lobe, and the patient was diagnosed with congenital CPHD based on decreased secretion of cortisol and GH by the pituitary anterior lobe load test. D-Bil levels promptly improved after hydrocortisone (HDC) replacement. We subsequently began replacement with levothyroxine (L-T 4 ) and GH, and liver histology showed normal interlobular bile ducts at 8 mo old. This is the first case report of proven histological improvement after hormone replacement therapy. This suggested that pituitary-mediated hormones, especially cortisol, might be involved in the development of the bile ducts.

  14. A case of an infant with congenital combined pituitary hormone deficiency and normalized liver histology of infantile cholestasis after hormone replacement therapy

    PubMed Central

    Wada, Keisuke; Kobayashi, Hironori; Moriyama, Aisa; Haneda, Yasuhiro; Mushimoto, Yuichi; Hasegawa, Yuki; Onigata, Kazumichi; Kumori, Koji; Ishikawa, Noriyoshi; Maruyama, Riruke; Sogo, Tsuyoshi; Murphy, Lynne; Taketani, Takeshi

    2017-01-01

    Abstract. Congenital combined pituitary hormone deficiency (CPHD) may present with cholestasis in the neonate or during early infancy. However, its precise mechanism is unknown. A 3-mo-old boy presented with cryptorchidism and hypoplastic scrotum after birth. Neonatal jaundice was noted but temporarily improved with phototherapy. Jaundice recurred at 2 mo of age. Elevated direct bilirubin (D-Bil) and liver dysfunction were found but cholangiography showed no signs of biliary atresia (BA). Liver biopsy findings showed giant cell formation of hepatocytes with hypoplastic bile ducts. Subsequent magnetic resonance imaging (MRI) of the head revealed a hypoplastic pituitary gland with an ectopic posterior lobe, and the patient was diagnosed with congenital CPHD based on decreased secretion of cortisol and GH by the pituitary anterior lobe load test. D-Bil levels promptly improved after hydrocortisone (HDC) replacement. We subsequently began replacement with levothyroxine (L-T4) and GH, and liver histology showed normal interlobular bile ducts at 8 mo old. This is the first case report of proven histological improvement after hormone replacement therapy. This suggested that pituitary-mediated hormones, especially cortisol, might be involved in the development of the bile ducts. PMID:29026274

  15. Call to Adopt a Nominal Set of Astrophysical Parameters and Constants to Improve the Accuracy of Fundamental Physical Properties of Stars

    NASA Astrophysics Data System (ADS)

    Harmanec, Petr; Prša, Andrej

    2011-08-01

    The increasing precision of astronomical observations of stars and stellar systems is gradually getting to a level where the use of slightly different values of the solar mass, radius, and luminosity, as well as different values of fundamental physical constants, can lead to measurable systematic differences in the determination of basic physical properties. An equivalent issue with an inconsistent value of the speed of light was resolved by adopting a nominal value that is constant and has no error associated with it. Analogously, we suggest that the systematic error in stellar parameters may be eliminated by (1) replacing the solar radius R⊙ and luminosity L⊙ by the nominal values that are by definition exact and expressed in SI units: and ; (2) computing stellar masses in terms of M⊙ by noting that the measurement error of the product GM⊙ is 5 orders of magnitude smaller than the error in G; (3) computing stellar masses and temperatures in SI units by using the derived values and ; and (4) clearly stating the reference for the values of the fundamental physical constants used. We discuss the need and demonstrate the advantages of such a paradigm shift.

  16. Comparison of the initial orthodontic force systems produced by a new lingual bracket system and a straight-wire appliance.

    PubMed

    Fuck, Lars-Michael; Wiechmann, Dirk; Drescher, Dieter

    2005-09-01

    Over the last few years, lingual appliances have become an established orthodontic treatment technique. Many studies have concentrated on various esthetic aspects, on laboratory and clinical procedures, and on patient comfort and compliance. The orthodontic force systems of these appliances, however, have not yet been investigated. The aim of this study was thus to determine the forces and moments produced by a new lingual bracket system during the leveling phase of orthodontic treatment and to compare those with the corresponding force system of a labial straight-wire appliance. The intra-oral situation of ten patients undergoing orthodontic treatment was replicated in measurement casts fitted with lingual and labial brackets. Special care was taken to precisely reproduce each patient's interbracket geometry. We measured each tooth's force systems as generated by a leveling arch inserted into the lingual and labial brackets. The resulting force systems of both appliances were found to be quite similar with regard to the magnitude of most force and moment components. Only the first molars were subjected to considerably greater single forces with the lingual appliance. Tipping moments were found to be significantly smaller with the lingual technique, whereas the rotational moments were significantly smaller with the labial appliance. All in all we noted significant differences between the two techniques only in certain areas which upon closer examination were distributed over only a few tooth types. The initial force systems produced by the new lingual bracket system proved to be comparable with those delivered by a conventional straight-wire appliance. The actual levels of forces and moments, however, were found in certain cases to be too heavy with both techniques. We therefore recommend the development of leveling wires producing considerably lighter forces and moments.

  17. Innovative Technique for the Placement of the Drainage Tube for Microendoscopic Spinal Decompression.

    PubMed

    Mizuno, Kentaro; Mikami, Yasuo; Hase, Hitoshi; Ikeda, Takumi; Nagae, Masateru; Tonomura, Hitoshi; Shirai, Toshiharu; Fujiwara, Hiroyoshi; Kubo, Toshikazu

    2017-02-01

    A technical note and retrospective study. The objectives were to describe a new method of drainage tube placement during microendoscopic spinal decompression, and compare the positioning and fluid discharge obtained with this method and the conventional method. To prevent postoperative epidural hematoma after microendoscopic decompression, a drainage tube must be placed in a suitable location. However, the narrow operative field makes precise control of the position of the tube technically difficult. We developed a method to reliably place the tube in the desired location. We use a Deschamps aneurysm needle with a slightly curved tip, which we call a drain passer. With the microendoscope in position, the drain passer, with a silk thread passed through the eye at the needle tip, is inserted percutaneously into the endoscopic field of view. The drainage tube is passed through the loop of silk thread protruding from the inside of the tubular retractor, and the thread is pulled to the outside, guiding the end of the drainage tube into the wound. This method was used in 23 cases at 44 intervertebral levels (drain passer group), and the conventional method in 20 cases at 32 intervertebral levels (conventional group). Postoperative plain radiographs were taken, and the amount of fluid discharge at postoperative hour 24 was measured. Drainage tube positioning was favorable at 43 intervertebral levels (97.7%) in the drain passer group and 26 intervertebral levels (81.3%) in the conventional group. Mean fluid discharge was 58.4±32.2 g in the drain passer group and 38.4±23.0 g in the conventional group. Positioning was significantly better and fluid discharge was significantly greater in the drain passer group. The results indicate that this method is a useful drainage tube placement technique for preventing postoperative epidural hematoma.

  18. Role of Repetitive Transcranial Magnetic Stimulation (rTMS) in Treatment of Addiction and Related Disorders: A Systematic Review.

    PubMed

    Makani, Ramkrishna; Pradhan, Basant; Shah, Umang; Parikh, Tapan

    2017-11-29

    Addiction and related disorders are devastating with their tremendous social, psychological, and physical consequences for which development of optimally effective treatments are long overdue. Repetitive transcranial magnetic stimulation (rTMS) is relatively safe and is becoming an emerging therapeutic tool for these conditions. This systematic review was conducted using PubMed, PsycINFO, PsychiatryOnline and Cochrane Library ranging from year 2001 to 2017. Our search retrieved 70 related articles of which, based on the Strength of Recommendation Taxonomy (SORT) guidelines, 33 indicated Level-1 study quality and class-B strength of recommendation for rTMS in nicotine addiction (effective in 218/289 subjects who received rTMS as found in 11 studies). Level-2/Class-B evidence was found for alcohol and cocaine addictions (Alcohol: effective in 126/193 subjects who received rTMS as found in 8 studies; Cocaine: effective in 86/128 subjects, as found in 5 studies). For food cravings, Level-3/Class-B evidence was noted (effective in 134/169, found in 7 studies). However, the evidence was limited to Level-3/Class-C for heroin (10/20 subjects received active rTMS, effective in 1 study), methamphetamine (33/48 subjects received active rTMS, effective in 2 studies), cannabis (18/18 subjects received active rTMS, effective in 1 study), and pathological gambling (31/31 subjects received active rTMS, effective in 2 studies). rTMS may serve as an emerging therapeutic option for addiction and related disorders. The major lacunae include important methodological limitations and dearth of knowledge about precise mechanism of action that need to be addressed in the future studies. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  19. Assessment of errors and biases in retrievals of X CO2, X CH4, X CO, and X N2O from a 0.5 cm –1 resolution solar-viewing spectrometer

    DOE PAGES

    Hedelius, Jacob K.; Viatte, Camille; Wunch, Debra; ...

    2016-08-03

    Bruker™ EM27/SUN instruments are commercial mobile solar-viewing near-IR spectrometers. They show promise for expanding the global density of atmospheric column measurements of greenhouse gases and are being marketed for such applications. They have been shown to measure the same variations of atmospheric gases within a day as the high-resolution spectrometers of the Total Carbon Column Observing Network (TCCON). However, there is little known about the long-term precision and uncertainty budgets of EM27/SUN measurements. In this study, which includes a comparison of 186 measurement days spanning 11 months, we note that atmospheric variations of X gas within a single day aremore » well captured by these low-resolution instruments, but over several months, the measurements drift noticeably. We present comparisons between EM27/SUN instruments and the TCCON using GGG as the retrieval algorithm. In addition, we perform several tests to evaluate the robustness of the performance and determine the largest sources of errors from these spectrometers. We include comparisons of X CO2, X CH4, X CO, and X N2O. Specifically we note EM27/SUN biases for January 2015 of 0.03, 0.75, –0.12, and 2.43 % for X CO2, X CH4, X CO, and X N2O respectively, with 1 σ running precisions of 0.08 and 0.06 % for X CO2 and X CH4 from measurements in Pasadena. We also identify significant error caused by nonlinear sensitivity when using an extended spectral range detector used to measure CO and N 2O.« less

  20. Dosimetric impact of daily setup variations during treatment of canine nasal tumors using intensity-modulated radiation therapy.

    PubMed

    Deveau, Michael A; Gutiérrez, Alonso N; Mackie, Thomas R; Tomé, Wolfgang A; Forrest, Lisa J

    2010-01-01

    Intensity-modulated radiation therapy (IMRT) can be employed to yield precise dose distributions that tightly conform to targets and reduce high doses to normal structures by generating steep dose gradients. Because of these sharp gradients, daily setup variations may have an adverse effect on clinical outcome such that an adjacent normal structure may be overdosed and/or the target may be underdosed. This study provides a detailed analysis of the impact of daily setup variations on optimized IMRT canine nasal tumor treatment plans when variations are not accounted for due to the lack of image guidance. Setup histories of ten patients with nasal tumors previously treated using helical tomotherapy were replanned retrospectively to study the impact of daily setup variations on IMRT dose distributions. Daily setup shifts were applied to IMRT plans on a fraction-by-fraction basis. Using mattress immobilization and laser alignment, mean setup error magnitude in any single dimension was at least 2.5 mm (0-10.0 mm). With inclusions of all three translational coordinates, mean composite offset vector was 5.9 +/- 3.3 mm. Due to variations, a loss of equivalent uniform dose for target volumes of up to 5.6% was noted which corresponded to a potential loss in tumor control probability of 39.5%. Overdosing of eyes and brain was noted by increases in mean normalized total dose and highest normalized dose given to 2% of the volume. Findings suggest that successful implementation of canine nasal IMRT requires daily image guidance to ensure accurate delivery of precise IMRT distributions when non-rigid immobilization techniques are utilized. Unrecognized geographical misses may result in tumor recurrence and/or radiation toxicities to the eyes and brain.

  1. DOSIMETRIC IMPACT OF DAILY SETUP VARIATIONS DURING TREATMENT OF CANINE NASAL TUMORS USING INTENSITY-MODULATED RADIATION THERAPY

    PubMed Central

    Deveau, Michael A.; Gutiérrez, Alonso N.; Mackie, Thomas R.; Tomé, Wolfgang A.; Forrest, Lisa J.

    2009-01-01

    Intensity-modulated radiation therapy (IMRT) can be employed to yield precise dose distributions that tightly conform to targets and reduce high doses to normal structures by generating steep dose gradients. Because of these sharp gradients, daily setup variations may have an adverse effect on clinical outcome such that an adjacent normal structure may be overdosed and/or the target may be underdosed. This study provides a detailed analysis of the impact of daily setup variations on optimized IMRT canine nasal tumor treatment plans when variations are not accounted for due to the lack of image guidance. Setup histories of ten patients with nasal tumors previously treated using helical tomotherapy were replanned retrospectively to study the impact of daily setup variations on IMRT dose distributions. Daily setup shifts were applied to IMRT plans on a fraction-by-fraction basis. Using mattress immobilization and laser alignment, mean setup error magnitude in any single dimension was at least 2.5mm (0-10.0mm). With inclusions of all three translational coordinates, mean composite offset vector was 5.9±3.3mm. Due to variations, a loss of equivalent uniform dose (EUD) for target volumes of up to 5.6% was noted which corresponded to a potential loss in TCP of 39.5%. Overdosing of eyes and brain was noted by increases in mean normalized total dose (NTDmean) and highest normalized dose given to 2% of the volume (NTD2%). Findings suggest that successful implementation of canine nasal IMRT requires daily image guidance to ensure accurate delivery of precise IMRT distributions when non-rigid immobilization techniques are utilized. Unrecognized geographical misses may result in tumor recurrence and/or radiation toxicities to the eyes and brain. PMID:20166402

  2. Bond Strength of Resin Cements to Dentin Using New Universal Bonding Agents

    DTIC Science & Technology

    2015-06-30

    34Bond Strength of Resin Cements to Dentin Using New Universal Bonding Agents" Materials Repaired with Composite Resin" 7. Intended publication...DoD- or US Gov’t-level policy, communications systems or weapons issues review"). *Note: It is DoD policy that clearance of information or material...University-, DoD- or US Gov’t-level policy, communications systems or weapons issues review"). *Note: It is DoD po/icy that clearance of

  3. Review Article: Mapping of children's health and development data on population level using the classification system ICF-CY.

    PubMed

    Ståhl, Ylva; Granlund, Mats; Gäre-Andersson, Boel; Enskär, Karin

    2011-02-01

    The aim of this study was to investigate if essential health and development data of all children in Sweden in the Child Health Service (CHS) and School Health Service (SHS) can be linked to the classification system International Classification of Functioning, Disability and Health--Children and Youth (ICF-CY). Lists of essential health terms, compiled by professionals from CHS and SHS, expected to be used in the national standardised records form the basis for the analysis in this study. The essential health terms have been linked to the codes of ICF-CY by using linking rules and a verification procedure. After exclusion of terms not directly describing children's health, a majority of the health terms could be linked into the ICF-CY with a high proportion of terms in body functions and a lower proportion in activity/participation and environment respectively. Some health terms had broad description and were linked to several ICF-CY codes. The precision of the health terms was at a medium level of detail. ICF-CY can be useful as a tool for documenting child health. It provides not only a code useful for statistical purposes but also a language useful for the CHS and SHS in their work on individual as well as population levels. It was noted that the health terms used by services mainly focused on health related to body function. This indicates that more focus is needed on health data related to child's functioning in everyday life situations.

  4. Estimated association between dwelling soil contamination and internal radiation contamination levels after the 2011 Fukushima Daiichi nuclear accident in Japan

    PubMed Central

    Tsubokura, Masaharu; Nomura, Shuhei; Sakaihara, Kikugoro; Kato, Shigeaki; Leppold, Claire; Furutani, Tomoyuki; Morita, Tomohiro; Oikawa, Tomoyoshi; Kanazawa, Yukio

    2016-01-01

    Objectives Measurement of soil contamination levels has been considered a feasible method for dose estimation of internal radiation exposure following the Chernobyl disaster by means of aggregate transfer factors; however, it is still unclear whether the estimation of internal contamination based on soil contamination levels is universally valid or incident specific. Methods To address this issue, we evaluated relationships between in vivo and soil cesium-137 (Cs-137) contamination using data on internal contamination levels among Minamisoma (10–40 km north from the Fukushima Daiichi nuclear power plant), Fukushima residents 2–3 years following the disaster, and constructed three models for statistical analysis based on continuous and categorical (equal intervals and quantiles) soil contamination levels. Results A total of 7987 people with a mean age of 55.4 years underwent screening of in vivo Cs-137 whole-body counting. A statistically significant association was noted between internal and continuous Cs-137 soil contamination levels (model 1, p value <0.001), although the association was slight (relative risk (RR): 1.03 per 10 kBq/m2 increase in soil contamination). Analysis of categorical soil contamination levels showed statistical (but not clinical) significance only in relatively higher soil contamination levels (model 2: Cs-137 levels above 100 kBq/m2 compared to those <25 kBq/m2, RR=1.75, p value <0.01; model 3: levels above 63 kBq/m2 compared to those <11 kBq/m2, RR=1.45, p value <0.05). Conclusions Low levels of internal and soil contamination were not associated, and only loose/small associations were observed in areas with slightly higher levels of soil contamination in Fukushima, representing a clear difference from the strong associations found in post-disaster Chernobyl. These results indicate that soil contamination levels generally do not contribute to the internal contamination of residents in Fukushima; thus, individual measurements are essential for the precise evaluation of chronic internal radiation contamination. PMID:27357196

  5. The effects of castration, preslaughter stress and zeranol implants on beef: Part 2-Cooking properties and flavor of loin steaks from bovine males.

    PubMed

    Jeremiah, L E; Newman, J A; Tong, A K; Gibson, L L

    1988-01-01

    A total of 144 male crossbred calves were allocated to four castration or implant treatments (unimplanted bulls; unimplanted steers; bulls implanted with zeranol at 100 days of age and reimplanted at intervals of 69, 93 and 56 days thereafter; bulls implanted with zeranol at 168 days of age and reimplanted at intervals of 93 and 56 days thereafter) and two preslaughter shipping treatments (minimum preslaughter stress, with cattle shipped and slaughtered within 4 h of leaving the feedlot pen; normal preslaughter stress, with cattle mixed, trucked 160 km, and slaughtered up to 24 h after leaving the feedlot pen). These cattle were slaughtered and striploin steaks were removed after 6 days of post-mortem aging. Evaluations of these steaks were then conducted using both an experienced laboratory taste panel and a highly trained professional flavor profile panel. Results indicated that: (1) steaks from bulls had higher cooking losses than their counterparts from steers, when minimum preslaughter stress was applied; and required longer cooking times under both preslaughter handling treatments; (2) steaks from unimplanted bulls had greater cooking losses and required longer cooking times than their counterparts from implanted bulls under normal preslaughter stress, but not under minimum preslaughter stress; (3) higher proportions of bull steaks than steer steaks contained inappropriate flavor character notes, under both minimum and normal levels of preslaughter stress; (4) both castration and preslaughter handling affected the intensity and order of appearance of specific flavor character notes; (5) the level of preslaughter stress significantly influenced the detection of specific flavor character notes in steaks from both bulls and steers; (6) steaks from steers under minimum preslaughter stress were rated significantly higher in flavor amplitude than their counterparts from bulls when under normal preslaughter stress, and steaks from steers under minimum preslaughter stress received higher flavor desirability scores than steaks from bulls under both minimum and normal preslaughter stress; (7) zeranol implants influenced the appearance and the order of appearance of specific flavor character notes under both minimum and normal levels of preslaughter stress; (8) both zeranol implants and the length of time animals were implanted appeared to increase the intensity of certain inappropriate character notes, and to decrease the intensity of certain appropriate character notes; (9) steaks from implanted bulls received lower flavor amplitude ratings than their counterparts from unimplanted bulls under normal preslaughter stress, but not under minimum preslaughter stress; (10) the level of preslaughter stress influenced both the appearance and order of appearance of specific flavor character notes in both implanted and unimplanted bull steaks; (11) the intensities of certain flavor character notes were influenced by differences in the level of preslaughter stress in both implanted and unimplanted bull steaks, and higher levels usually resulted in inappropriate character notes being more intense; (12) steaks from bulls in both implant groups received lower flavor amplitude ratings when normal preslaughter stress was applied, clearly indicating the deleterious effect of the combination of zeranol implants and normal preslaughter stress on bull beef flavor; and (13) the deleterious effect of the combination of zeranol implants and normal preslaughter stress on bull beef flavor could not be explaind on the basis of greater production of 'dark cutting' beef. Copyright © 1988. Published by Elsevier Ltd.

  6. Applying Questioning or Reading Strategy to Review Technology Enhanced Coedited Notes of Elementary School Students

    ERIC Educational Resources Information Center

    Chiu, Chiung-Hui; Cheng, Hsiao-Wei; Wu, Chiu-Yi

    2016-01-01

    The authors examined whether applying questioning review better enhances elementary level students' learning from technology-enhanced coediting-based note taking than does traditional reading review. A nonequivalent comparison group quasi-experimental design was implemented and replicated on four independent units. Two sixth grade elementary…

  7. Adolescence: A "Risk Factor" for Physical Inactivity.

    ERIC Educational Resources Information Center

    Rowland, Thomas W.

    1999-01-01

    This publication examines influences on the present and future physical activity levels of adolescents, noting that the adolescents' physical activity habits, as well as other risk factors, are likely to track into the adult years. Section 1 discusses physical activity in adolescence, noting that adolescence is a time when physical activity tends…

  8. Accuracy and precision of stream reach water surface slopes estimated in the field and from maps

    USGS Publications Warehouse

    Isaak, D.J.; Hubert, W.A.; Krueger, K.L.

    1999-01-01

    The accuracy and precision of five tools used to measure stream water surface slope (WSS) were evaluated. Water surface slopes estimated in the field with a clinometer or from topographic maps used in conjunction with a map wheel or geographic information system (GIS) were significantly higher than WSS estimated in the field with a surveying level (biases of 34, 41, and 53%, respectively). Accuracy of WSS estimates obtained with an Abney level did not differ from surveying level estimates, but conclusions regarding the accuracy of Abney levels and clinometers were weakened by intratool variability. The surveying level estimated WSS most precisely (coefficient of variation [CV] = 0.26%), followed by the GIS (CV = 1.87%), map wheel (CV = 6.18%), Abney level (CV = 13.68%), and clinometer (CV = 21.57%). Estimates of WSS measured in the field with an Abney level and estimated for the same reaches with a GIS used in conjunction with l:24,000-scale topographic maps were significantly correlated (r = 0.86), but there was a tendency for the GIS to overestimate WSS. Detailed accounts of the methods used to measure WSS and recommendations regarding the measurement of WSS are provided.

  9. Readability Formulas and User Perceptions of Electronic Health Records Difficulty: A Corpus Study

    PubMed Central

    Yu, Hong

    2017-01-01

    Background Electronic health records (EHRs) are a rich resource for developing applications to engage patients and foster patient activation, thus holding a strong potential to enhance patient-centered care. Studies have shown that providing patients with access to their own EHR notes may improve the understanding of their own clinical conditions and treatments, leading to improved health care outcomes. However, the highly technical language in EHR notes impedes patients’ comprehension. Numerous studies have evaluated the difficulty of health-related text using readability formulas such as Flesch-Kincaid Grade Level (FKGL), Simple Measure of Gobbledygook (SMOG), and Gunning-Fog Index (GFI). They conclude that the materials are often written at a grade level higher than common recommendations. Objective The objective of our study was to explore the relationship between the aforementioned readability formulas and the laypeople’s perceived difficulty on 2 genres of text: general health information and EHR notes. We also validated the formulas’ appropriateness and generalizability on predicting difficulty levels of highly complex technical documents. Methods We collected 140 Wikipedia articles on diabetes and 242 EHR notes with diabetes International Classification of Diseases, Ninth Revision code. We recruited 15 Amazon Mechanical Turk (AMT) users to rate difficulty levels of the documents. Correlations between laypeople’s perceived difficulty levels and readability formula scores were measured, and their difference was tested. We also compared word usage and the impact of medical concepts of the 2 genres of text. Results The distributions of both readability formulas’ scores (P<.001) and laypeople’s perceptions (P=.002) on the 2 genres were different. Correlations of readability predictions and laypeople’s perceptions were weak. Furthermore, despite being graded at similar levels, documents of different genres were still perceived with different difficulty (P<.001). Word usage in the 2 related genres still differed significantly (P<.001). Conclusions Our findings suggested that the readability formulas’ predictions did not align with perceived difficulty in either text genre. The widely used readability formulas were highly correlated with each other but did not show adequate correlation with readers’ perceived difficulty. Therefore, they were not appropriate to assess the readability of EHR notes. PMID:28254738

  10. The Nature of the Nodes, Weights and Degree of Precision in Gaussian Quadrature Rules

    ERIC Educational Resources Information Center

    Prentice, J. S. C.

    2011-01-01

    We present a comprehensive proof of the theorem that relates the weights and nodes of a Gaussian quadrature rule to its degree of precision. This level of detail is often absent in modern texts on numerical analysis. We show that the degree of precision is maximal, and that the approximation error in Gaussian quadrature is minimal, in a…

  11. Necrotic and inflammatory changes in metal-on-metal resurfacing hip arthroplasties

    PubMed Central

    2009-01-01

    Background Necrosis and inflammation in peri-implant soft tissues have been described in failed second-generation metal-on-metal (MoM) resurfacing hip arthroplasties and in the pseudotumors associated with these implants. The precise frequency and significance of these tissue changes is unknown. Method We analyzed morphological and immunophenotypic changes in the periprosthetic soft tissues and femoral heads of 52 revised MoM arthroplasties (fracture in 21, pseudotumor in 13, component loosening in 9, and other causes in 9 cases). Results Substantial necrosis was observed in the periprosthetic connective tissue in 28 of the cases, including all pseudotumors, and 5 cases of component loosening. A heavy, diffuse inflammatory cell infiltrate composed mainly of HLA-DR+/CD14+/CD68+ macrophages and CD3+ T cells was seen in 45 of the cases. Perivascular lymphoid aggregates composed of CD3+ cells and CD20+ B cells were noted in 27 of the cases, but they were not seen in all cases of component loosening or pseudotumors. Plasma cells were noted in 30 cases. Macrophage granulomas were noted in 6 cases of component loosening. In the bone marrow of the femoral head, a macrophage and T cell response was seen in 31 of the cases; lymphoid aggregates were noted in 19 of the cases and discrete granulomas in 1 case. Interpretation Our findings indicate that there is a spectrum of necrotic and inflammatory changes in response to the deposition of cobalt-chrome (Co-Cr) wear particles in periprosthetic tissues. Areas of extensive coagulative necrosis and a macrophage and T lymphocyte response occur in implant failure and pseudotumors, in which there is also granuloma formation. The pathogenesis of these changes is uncertain but it may involve both a cytotoxic response and a delayed hypersensitivity (type IV) response to Co-Cr particles. PMID:19995315

  12. Precision of information, sensational information, and self-efficacy information as message-level variables affecting risk perceptions.

    PubMed

    Dahlstrom, Michael F; Dudo, Anthony; Brossard, Dominique

    2012-01-01

    Studies that investigate how the mass media cover risk issues often assume that certain characteristics of content are related to specific risk perceptions and behavioral intentions. However, these relationships have seldom been empirically assessed. This study tests the influence of three message-level media variables--risk precision information, sensational information, and self-efficacy information--on perceptions of risk, individual worry, and behavioral intentions toward a pervasive health risk. Results suggest that more precise risk information leads to increased risk perceptions and that the effect of sensational information is moderated by risk precision information. Greater self-efficacy information is associated with greater intention to change behavior, but none of the variables influence individual worry. The results provide a quantitative understanding of how specific characteristics of informational media content can influence individuals' responses to health threats of a global and uncertain nature. © 2011 Society for Risk Analysis.

  13. Single-cell-precision microplasma-induced cancer cell apoptosis.

    PubMed

    Tan, Xiao; Zhao, Shasha; Lei, Qian; Lu, Xinpei; He, Guangyuan; Ostrikov, Kostya

    2014-01-01

    The issue of single-cell control has recently attracted enormous interest. However, in spite of the presently achievable intracellular-level physiological probing through bio-photonics, nano-probe-based, and some other techniques, the issue of inducing selective, single-cell-precision apoptosis, without affecting neighbouring cells remains essentially open. Here we resolve this issue and report on the effective single-cell-precision cancer cell treatment using the reactive chemistry of the localized corona-type plasma discharge around a needle-like electrode with the spot size ∼1 µm. When the electrode is positioned with the micrometer precision against a selected cell, a focused and highly-localized micro-plasma discharge induces apoptosis in the selected individual HepG2 and HeLa cancer cells only, without affecting any surrounding cells, even in small cell clusters. This is confirmed by the real-time monitoring of the morphological and structural changes at the cellular and cell nucleus levels after the plasma exposure.

  14. Effects of precision demands and mental pressure on muscle activation and hand forces in computer mouse tasks.

    PubMed

    Visser, Bart; De Looze, Michiel; De Graaff, Matthijs; Van Dieën, Jaap

    2004-02-05

    The objective of the present study was to gain insight into the effects of precision demands and mental pressure on the load of the upper extremity. Two computer mouse tasks were used: an aiming and a tracking task. Upper extremity loading was operationalized as the myo-electric activity of the wrist flexor and extensor and of the trapezius descendens muscles and the applied grip- and click-forces on the computer mouse. Performance measures, reflecting the accuracy in both tasks and the clicking rate in the aiming task, indicated that the levels of the independent variables resulted in distinguishable levels of accuracy and work pace. Precision demands had a small effect on upper extremity loading with a significant increase in the EMG-amplitudes (21%) of the wrist flexors during the aiming tasks. Precision had large effects on performance. Mental pressure had substantial effects on EMG-amplitudes with an increase of 22% in the trapezius when tracking and increases of 41% in the trapezius and 45% and 140% in the wrist extensors and flexors, respectively, when aiming. During aiming, grip- and click-forces increased by 51% and 40% respectively. Mental pressure had small effects on accuracy but large effects on tempo during aiming. Precision demands and mental pressure in aiming and tracking tasks with a computer mouse were found to coincide with increased muscle activity in some upper extremity muscles and increased force exertion on the computer mouse. Mental pressure caused significant effects on these parameters more often than precision demands. Precision and mental pressure were found to have effects on performance, with precision effects being significant for all performance measures studied and mental pressure effects for some of them. The results of this study suggest that precision demands and mental pressure increase upper extremity load, with mental pressure effects being larger than precision effects. The possible role of precision demands as an indirect mental stressor in working conditions is discussed.

  15. Real-Time Single Frequency Precise Point Positioning Using SBAS Corrections

    PubMed Central

    Li, Liang; Jia, Chun; Zhao, Lin; Cheng, Jianhua; Liu, Jianxu; Ding, Jicheng

    2016-01-01

    Real-time single frequency precise point positioning (PPP) is a promising technique for high-precision navigation with sub-meter or even centimeter-level accuracy because of its convenience and low cost. The navigation performance of single frequency PPP heavily depends on the real-time availability and quality of correction products for satellite orbits and satellite clocks. Satellite-based augmentation system (SBAS) provides the correction products in real-time, but they are intended to be used for wide area differential positioning at 1 meter level precision. By imposing the constraints for ionosphere error, we have developed a real-time single frequency PPP method by sufficiently utilizing SBAS correction products. The proposed PPP method are tested with static and kinematic data, respectively. The static experimental results show that the position accuracy of the proposed PPP method can reach decimeter level, and achieve an improvement of at least 30% when compared with the traditional SBAS method. The positioning convergence of the proposed PPP method can be achieved in 636 epochs at most in static mode. In the kinematic experiment, the position accuracy of the proposed PPP method can be improved by at least 20 cm relative to the SBAS method. Furthermore, it has revealed that the proposed PPP method can achieve decimeter level convergence within 500 s in the kinematic mode. PMID:27517930

  16. A Comparative Study of the Applied Methods for Estimating Deflection of the Vertical in Terrestrial Geodetic Measurements

    PubMed Central

    Vittuari, Luca; Tini, Maria Alessandra; Sarti, Pierguido; Serantoni, Eugenio; Borghi, Alessandra; Negusini, Monia; Guillaume, Sébastien

    2016-01-01

    This paper compares three different methods capable of estimating the deflection of the vertical (DoV): one is based on the joint use of high precision spirit leveling and Global Navigation Satellite Systems (GNSS), a second uses astro-geodetic measurements and the third gravimetric geoid models. The working data sets refer to the geodetic International Terrestrial Reference Frame (ITRF) co-location sites of Medicina (Northern, Italy) and Noto (Sicily), these latter being excellent test beds for our investigations. The measurements were planned and realized to estimate the DoV with a level of precision comparable to the angular accuracy achievable in high precision network measured by modern high-end total stations. The three methods are in excellent agreement, with an operational supremacy of the astro-geodetic method, being faster and more precise than the others. The method that combines leveling and GNSS has slightly larger standard deviations; although well within the 1 arcsec level, which was assumed as threshold. Finally, the geoid model based method, whose 2.5 arcsec standard deviations exceed this threshold, is also statistically consistent with the others and should be used to determine the DoV components where local ad hoc measurements are lacking. PMID:27104544

  17. A facile strategy for fine-tuning the stability and drug release of stimuli-responsive cross-linked micellar nanoparticles towards precision drug delivery.

    PubMed

    Xiao, Kai; Lin, Tzu-Yin; Lam, Kit S; Li, Yuanpei

    2017-06-14

    Precision drug delivery has a great impact on the application of precision oncology for better patient care. Here we report a facile strategy for fine-tuning the stability, drug release and responsiveness of stimuli-responsive cross-linked nanoparticles towards precision drug delivery. A series of micellar nanoparticles with different levels of intramicellar disulfide crosslinkages could be conveniently produced with a mixed micelle approach. These micellar nanoparticles were all within a size range of 25-40 nm so that they could take full advantage of the enhanced permeability and retention (EPR) effect for tumor-targeted drug delivery. The properties of these nanoparticles such as critical micelle concentration (CMC), stability, drug release and responsiveness to a reductive environment could be well correlated with the levels of crosslinking (LOC). Compared to the micellar nanoparticles with a LOC at 0% that caused the death of animals of two species (mouse and rat) due to the acute toxicity such as hemolysis, the nanoparticles at all other levels of crosslinking were much safer to be administered into animals. The in vitro antitumor efficacy of micellar nanoparticles crosslinked at lower levels (20% & 50%) were much more effective than that of 100% crosslinked micellar nanoparticles in SKOV-3 ovarian cancer cells.

  18. Development of the One Centimeter Accuracy Geoid Model of Latvia for GNSS Measurements

    NASA Astrophysics Data System (ADS)

    Balodis, J.; Silabriedis, G.; Haritonova, D.; Kaļinka, M.; Janpaule, I.; Morozova, K.; Jumāre, I.; Mitrofanovs, I.; Zvirgzds, J.; Kaminskis, J.; Liepiņš, I.

    2015-11-01

    There is an urgent necessity for a highly accurate and reliable geoid model to enable prompt determination of normal height with the use of GNSS coordinate determination due to the high precision requirements in geodesy, building and high precision road construction development. Additionally, the Latvian height system is in the process of transition from BAS- 77 (Baltic Height System) to EVRS2007 system. The accuracy of the geoid model must approach the precision of about ∼1 cm looking forward to the Baltic Rail and other big projects. The use of all the available and verified data sources is planned, including the use of enlarged set of GNSS/levelling data, gravimetric measurement data and, additionally, the vertical deflection measurements over the territory of Latvia. The work is going ahead stepwise. Just the issue of GNSS reference network stability is discussed. In order to achieve the ∼1 cm precision geoid, it is required to have a homogeneous high precision GNSS network as a basis for ellipsoidal height determination for GNSS/levelling points. Both the LatPos and EUPOS® - Riga network have been examined in this article.

  19. Radiative Transfer in Stellar Atmospheres

    NASA Astrophysics Data System (ADS)

    Rutten, Robert J.

    2003-05-01

    The main topic treated in these graduate course notes is the classical theory of radiative transfer for explaining stellar spectra. It needs relatively much attention to be mastered. Radiative transfer in gaseous media that are neither optically thin nor fully opaque and scatter to boot is a key part of astrophysics but not a transparent subject. These course notes represent a middle road between Mihalas' "Stellar Atmospheres" (graduate level and up) and the books by Novotny and Boehm-Vitense (undergraduate level). They are at about the level of Gray's "The observation and analysis of stellar photospheres" but emphasize NLTE radiative transfer rather than observational techniques and data interpretation.

  20. Optical frequency locked loop for long-term stabilization of broad-line DFB laser frequency difference

    NASA Astrophysics Data System (ADS)

    Lipka, Michał; Parniak, Michał; Wasilewski, Wojciech

    2017-09-01

    We present an experimental realization of the optical frequency locked loop applied to long-term frequency difference stabilization of broad-line DFB lasers along with a new independent method to characterize relative phase fluctuations of two lasers. The presented design is based on a fast photodiode matched with an integrated phase-frequency detector chip. The locking setup is digitally tunable in real time, insensitive to environmental perturbations and compatible with commercially available laser current control modules. We present a simple model and a quick method to optimize the loop for a given hardware relying exclusively on simple measurements in time domain. Step response of the system as well as phase characteristics closely agree with the theoretical model. Finally, frequency stabilization for offsets within 4-15 GHz working range achieving <0.1 Hz long-term stability of the beat note frequency for 500 s averaging time period is demonstrated. For these measurements we employ an I/Q mixer that allows us to precisely and independently measure the full phase trace of the beat note signal.

  1. Studying Associations Between Heart Failure Self-Management and Rehospitalizations Using Natural Language Processing.

    PubMed

    Topaz, Maxim; Radhakrishnan, Kavita; Blackley, Suzanne; Lei, Victor; Lai, Kenneth; Zhou, Li

    2016-09-14

    This study developed an innovative natural language processing algorithm to automatically identify heart failure (HF) patients with ineffective self-management status (in the domains of diet, physical activity, medication adherence, and adherence to clinician appointments) from narrative discharge summary notes. We also analyzed the association between self-management status and preventable 30-day hospital readmissions. Our natural language system achieved relatively high accuracy (F-measure = 86.3%; precision = 95%; recall = 79.2%) on a testing sample of 300 notes annotated by two human reviewers. In a sample of 8,901 HF patients admitted to our healthcare system, 14.4% (n = 1,282) had documentation of ineffective HF self-management. Adjusted regression analyses indicated that presence of any skill-related self-management deficit (odds ratio [OR] = 1.3, 95% confidence interval [CI] = [1.1, 1.6]) and non-specific ineffective self-management (OR = 1.5, 95% CI = [1.2, 2]) was significantly associated with readmissions. We have demonstrated the feasibility of identifying ineffective HF self-management from electronic discharge summaries with natural language processing. © The Author(s) 2016.

  2. Experimental implementation of phase locking in a nonlinear interferometer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Hailong; Jing, Jietai, E-mail: jtjing@phy.ecnu.edu.cn; Marino, A. M.

    2015-09-21

    Based upon two cascade four-wave mixing processes in two identical hot rubidium vapor cells, a nonlinear interferometer has been experimentally realized [Jing et al., Appl. Phys. Lett. 99, 011110 (2011); Hudelist et al., Nat. Commun. 5, 3049 (2014)]. It has a higher degree of phase sensitivity than a traditional linear interferometer and has many potential applications in quantum metrology. Phase locking of the nonlinear interferometer is needed before it can find its way into applications. In this letter, we investigate the experimental implementation of phase locking of the relative phase between the three beams at different frequencies involved in suchmore » a nonlinear interferometer. We have utilized two different methods, namely, beat note locking and coherent modulation locking. We find that coherent modulation locking can achieve much better phase stability than beat note locking in our system. Our results pave the way for real applications of a nonlinear interferometer in precision measurement and quantum manipulation, for example, phase control in phase-sensitive N-wave mixing process, N-port nonlinear interferometer and quantum-enhanced real-time phase tracking.« less

  3. On-chip dual-comb source for spectroscopy.

    PubMed

    Dutt, Avik; Joshi, Chaitanya; Ji, Xingchen; Cardenas, Jaime; Okawachi, Yoshitomo; Luke, Kevin; Gaeta, Alexander L; Lipson, Michal

    2018-03-01

    Dual-comb spectroscopy is a powerful technique for real-time, broadband optical sampling of molecular spectra, which requires no moving components. Recent developments with microresonator-based platforms have enabled frequency combs at the chip scale. However, the need to precisely match the resonance wavelengths of distinct high quality-factor microcavities has hindered the development of on-chip dual combs. We report the simultaneous generation of two microresonator combs on the same chip from a single laser, drastically reducing experimental complexity. We demonstrate broadband optical spectra spanning 51 THz and low-noise operation of both combs by deterministically tuning into soliton mode-locked states using integrated microheaters, resulting in narrow (<10 kHz) microwave beat notes. We further use one comb as a reference to probe the formation dynamics of the other comb, thus introducing a technique to investigate comb evolution without auxiliary lasers or microwave oscillators. We demonstrate high signal-to-noise ratio absorption spectroscopy spanning 170 nm using the dual-comb source over a 20-μs acquisition time. Our device paves the way for compact and robust spectrometers at nanosecond time scales enabled by large beat-note spacings (>1 GHz).

  4. Bias, precision and statistical power of analysis of covariance in the analysis of randomized trials with baseline imbalance: a simulation study.

    PubMed

    Egbewale, Bolaji E; Lewis, Martyn; Sim, Julius

    2014-04-09

    Analysis of variance (ANOVA), change-score analysis (CSA) and analysis of covariance (ANCOVA) respond differently to baseline imbalance in randomized controlled trials. However, no empirical studies appear to have quantified the differential bias and precision of estimates derived from these methods of analysis, and their relative statistical power, in relation to combinations of levels of key trial characteristics. This simulation study therefore examined the relative bias, precision and statistical power of these three analyses using simulated trial data. 126 hypothetical trial scenarios were evaluated (126,000 datasets), each with continuous data simulated by using a combination of levels of: treatment effect; pretest-posttest correlation; direction and magnitude of baseline imbalance. The bias, precision and power of each method of analysis were calculated for each scenario. Compared to the unbiased estimates produced by ANCOVA, both ANOVA and CSA are subject to bias, in relation to pretest-posttest correlation and the direction of baseline imbalance. Additionally, ANOVA and CSA are less precise than ANCOVA, especially when pretest-posttest correlation ≥ 0.3. When groups are balanced at baseline, ANCOVA is at least as powerful as the other analyses. Apparently greater power of ANOVA and CSA at certain imbalances is achieved in respect of a biased treatment effect. Across a range of correlations between pre- and post-treatment scores and at varying levels and direction of baseline imbalance, ANCOVA remains the optimum statistical method for the analysis of continuous outcomes in RCTs, in terms of bias, precision and statistical power.

  5. Bias, precision and statistical power of analysis of covariance in the analysis of randomized trials with baseline imbalance: a simulation study

    PubMed Central

    2014-01-01

    Background Analysis of variance (ANOVA), change-score analysis (CSA) and analysis of covariance (ANCOVA) respond differently to baseline imbalance in randomized controlled trials. However, no empirical studies appear to have quantified the differential bias and precision of estimates derived from these methods of analysis, and their relative statistical power, in relation to combinations of levels of key trial characteristics. This simulation study therefore examined the relative bias, precision and statistical power of these three analyses using simulated trial data. Methods 126 hypothetical trial scenarios were evaluated (126 000 datasets), each with continuous data simulated by using a combination of levels of: treatment effect; pretest-posttest correlation; direction and magnitude of baseline imbalance. The bias, precision and power of each method of analysis were calculated for each scenario. Results Compared to the unbiased estimates produced by ANCOVA, both ANOVA and CSA are subject to bias, in relation to pretest-posttest correlation and the direction of baseline imbalance. Additionally, ANOVA and CSA are less precise than ANCOVA, especially when pretest-posttest correlation ≥ 0.3. When groups are balanced at baseline, ANCOVA is at least as powerful as the other analyses. Apparently greater power of ANOVA and CSA at certain imbalances is achieved in respect of a biased treatment effect. Conclusions Across a range of correlations between pre- and post-treatment scores and at varying levels and direction of baseline imbalance, ANCOVA remains the optimum statistical method for the analysis of continuous outcomes in RCTs, in terms of bias, precision and statistical power. PMID:24712304

  6. Usefulness of high-resolution 3D multifusion medical imaging for preoperative planning in patients with posterior fossa hemangioblastoma: technical note.

    PubMed

    Yoshino, Masanori; Nakatomi, Hirofumi; Kin, Taichi; Saito, Toki; Shono, Naoyuki; Nomura, Seiji; Nakagawa, Daichi; Takayanagi, Shunsaku; Imai, Hideaki; Oyama, Hiroshi; Saito, Nobuhito

    2017-07-01

    Successful resection of hemangioblastoma depends on preoperative assessment of the precise locations of feeding arteries and draining veins. Simultaneous 3D visualization of feeding arteries, draining veins, and surrounding structures is needed. The present study evaluated the usefulness of high-resolution 3D multifusion medical imaging (hr-3DMMI) for preoperative planning of hemangioblastoma. The hr-3DMMI combined MRI, MR angiography, thin-slice CT, and 3D rotated angiography. Surface rendering was mainly used for the creation of hr-3DMMI using multiple thresholds to create 3D models, and processing took approximately 3-5 hours. This hr-3DMMI technique was used in 5 patients for preoperative planning and the imaging findings were compared with the operative findings. Hr-3DMMI could simulate the whole 3D tumor as a unique sphere and show the precise penetration points of both feeding arteries and draining veins with the same spatial relationships as the original tumor. All feeding arteries and draining veins were found intraoperatively at the same position as estimated preoperatively, and were occluded as planned preoperatively. This hr-3DMMI technique could demonstrate the precise locations of feeding arteries and draining veins preoperatively and estimate the appropriate route for resection of the tumor. Hr-3DMMI is expected to be a very useful support tool for surgery of hemangioblastoma.

  7. Enumeration of residual white blood cells in leukoreduced blood products: Comparing flow cytometry with a portable microscopic cell counter.

    PubMed

    Castegnaro, Silvia; Dragone, Patrizia; Chieregato, Katia; Alghisi, Alberta; Rodeghiero, Francesco; Astori, Giuseppe

    2016-04-01

    Transfusion of blood components is potentially associated to the risk of cell-mediated adverse events and current guidelines require a reduction of residual white blood cells (rWBC) below 1 × 10(6) WBC/unit. The reference method to enumerate rare events is the flow cytometry (FCM). The ADAM-rWBC microscopic cell counter has been proposed as an alternative: it measures leukocytes after their staining with propidium iodide. We have tested the Adam-rWBC for the ability to enumerate rWBC in red blood cells and concentrates. We have validated the flow cytometry (FCM) for linearity, precision accuracy and robustness and then the ADAM-rWBC results have been compared with the FCM. Our data confirm the linearity, accuracy, precision and robustness of the FCM. The ADAM-rWBC has revealed an adequate precision and accuracy. Even if the Bland-Altman analysis of the paired data has indicated that the two systems are comparable, it should be noted that the rWBC values obtained by the ADAM-rWBC were significantly higher compared to FCM. In conclusion, the Adam-rWBC cell counter could represent an alternative where FCM technology expertise is not available, even if the risk that borderline products could be misclassified exists. Copyright © 2015 Elsevier Ltd. All rights reserved.

  8. Fixed-Precision Sequential Sampling Plans for Estimating Alfalfa Caterpillar, Colias lesbia, Egg Density in Alfalfa, Medicago sativa, Fields in Córdoba, Argentina

    PubMed Central

    Serra, Gerardo V.; Porta, Norma C. La; Avalos, Susana; Mazzuferi, Vilma

    2013-01-01

    The alfalfa caterpillar, Colias lesbia (Fabricius) (Lepidoptera: Pieridae), is a major pest of alfalfa, Medicago sativa L. (Fabales: Fabaceae), crops in Argentina. Its management is based mainly on chemical control of larvae whenever the larvae exceed the action threshold. To develop and validate fixed-precision sequential sampling plans, an intensive sampling programme for C. lesbia eggs was carried out in two alfalfa plots located in the Province of Córdoba, Argentina, from 1999 to 2002. Using Resampling for Validation of Sampling Plans software, 12 additional independent data sets were used to validate the sequential sampling plan with precision levels of 0.10 and 0.25 (SE/mean), respectively. For a range of mean densities of 0.10 to 8.35 eggs/sample, an average sample size of only 27 and 26 sample units was required to achieve a desired precision level of 0.25 for the sampling plans of Green and Kuno, respectively. As the precision level was increased to 0.10, average sample size increased to 161 and 157 sample units for the sampling plans of Green and Kuno, respectively. We recommend using Green's sequential sampling plan because it is less sensitive to changes in egg density. These sampling plans are a valuable tool for researchers to study population dynamics and to evaluate integrated pest management strategies. PMID:23909840

  9. Middle atmosphere composition revealed by satellite observations

    NASA Technical Reports Server (NTRS)

    Russell, J. M., III; Solomon, S.; Mccormick, M. P.; Miller, A. J.; Barnett, J. J.; Jones, R. L.; Rusch, D. W.

    1986-01-01

    A series of plots that describe the state of the stratosphere and to some degree, the mesosphere as revealed by satellite observations are shown. The pertinent instrument features, spatial and temporal coverage, and details of accuracy and precision for the experiments providing the data were described. The main features of zonal mean cross sections and polar stereographic projections were noted and intercomparisons were discussed where a parameter was measured by more than one experiment. The main purpose was to collect the available data in one place and provide enough inforamation on limitations or cautions about the data so that they could be used in model comparisons and science studies.

  10. Mars Exploration Rover Potentiometer Problems, Failures and Lessons Learned

    NASA Technical Reports Server (NTRS)

    Balzer, Mark

    2006-01-01

    During qualification testing of three types of non-wire-wound precision potentiometers for the Mars Exploration Rover, a variety of problems and failures were encountered. This paper will describe some of the more interesting problems, detail their investigations and present their final solutions. The failures were found to be caused by design errors, manufacturing errors, improper handling, test errors, and carelessness. A trend of decreasing total resistance was noted, and a resistance histogram was used to identify an outlier. A gang fixture is described for simultaneously testing multiple pots, and real time X-ray imaging was used extensively to assist in the failure analyses. Lessons learned are provided.

  11. Mars Exploration Rover potentiometer problems, failures and lessons learned

    NASA Technical Reports Server (NTRS)

    Balzer, Mark A.

    2006-01-01

    During qualification testing of three types of nonwire-wound precision potentiometers for the Mars Exploration Rover, a variety of problems and failures were encountered. This paper will describe some of the more interesting problems, detail their investigations and present their final solutions. The failures were found to be caused by design errors, manufacturing errors, improper handling, test errors, and carelessness. A trend of decreasing total resistance was noted, and a resistance histogram was used to identify an outlier. A gang fixture is described for simultaneously testing multiple pots, and real time X-ray imaging was used extensively to assist in the failure analyses. Lessons learned are provided.

  12. Phase contrast X-ray microtomography of the Rhodnius prolixus head: Comparison of direct reconstruction and phase retrieval approach

    NASA Astrophysics Data System (ADS)

    Almeida, A. P.; Braz, D.; Nogueira, L. P.; Colaço, M. V.; Soares, J.; Cardoso, S. C.; Garcia, E. S.; Azambuja, P.; Gonzalez, M. S.; Mohammadi, S.; Tromba, G.; Barroso, R. C.

    2014-02-01

    We have used phase-contrast X-ray microtomography (PPC-μCT) to study the head of the blood-feeding bug, Rhodnius prolixus, which is one of the most important insect vector of Trypanosoma cruzi, ethiologic agent of Chagas disease in Latin America. Images reconstructed from phase-retrieved projections processed by ANKA phase are compared to those obtained through direct tomographic reconstruction of the flat-field-corrected transmission radiographs. It should be noted that the relative locations of the important morphological internal structures are observable with a precision that is difficult to obtain without the phase retrieval approach.

  13. Note: A novel rotary actuator driven by only one piezoelectric actuator.

    PubMed

    Huang, Hu; Fu, Lu; Zhao, Hongwei; Shi, Chengli; Ren, Luquan; Li, Jianping; Qu, Han

    2013-09-01

    This paper presents a novel piezo-driven rotary actuator based on the parasitic motion principle. Output performances of the rotary actuator were tested and discussed. Experiment results indicate that using only one piezoelectric actuator and simple sawtooth wave control, the rotary actuator reaches the rotation velocity of about 20,097 μrad/s when the driving voltage is 100 V and the driving frequency is 90 Hz. The actuator can rotate stably with the minimum resolution of 0.7 μrad. This paper verifies feasibility of the parasitic motion principle for applications of rotary actuators, providing new design ideas for precision piezoelectric rotary actuators.

  14. Technical Note: evaluation of the uncertainties in (choline + creatine)/citrate ratios measured by proton MR spectroscopic imaging in patients suspicious for prostate cancer.

    PubMed

    Zbýň, Š; Krššák, M; Memarsadeghi, M; Gholami, B; Haitel, A; Weber, M; Helbich, T H; Trattnig, S; Moser, E; Gruber, S

    2014-07-01

    The presented evaluation of the relative uncertainty (δ'CCC) of the (choline + creatine)/citrate (CC/C) ratios can provide objective information about the quality and diagnostic value of prostate MR spectroscopic imaging data. This information can be combined with the numeric values of CC/C ratios and provides metabolic-quality maps enabling accurate cancer detection and user-independent data evaluation. In addition, the prostate areas suffering most from the low precision of CC/C ratios (e. g., prostate base) were identified. © Georg Thieme Verlag KG Stuttgart · New York.

  15. The QBO and interannual variation in total ozone

    NASA Technical Reports Server (NTRS)

    Lait, Leslie R.; Schoeberl, Mark R.; Newman, Paul A.; Stolarski, Richard S.

    1988-01-01

    Garcia and Soloman (1987) have noted that the October monthly mean minimum total ozone amounts south of 30 S were modulated by a quasibiennial oscillation (QBO) signal. The precise mechanism behind this effect, however, is unclear. Is the modulation brought about by the circulation-produced QBO signal in the ozone concentration itself, or does the temperature QBO modulate the formation of polar stratospheric clouds (PSCs), leading to changes in the chemically induced Antarctic spring ozone decline rate. Or is some other phenomenon involved. To investigate the means through which the QBO effect occurs, a series of correlation studies has been made between polar ozone and QBO signal in ozone and temperature.

  16. Note: Comparison experimental results of the laser heterodyne interferometer for angle measurement based on the Faraday effect.

    PubMed

    Zhang, Enzheng; Chen, Benyong; Zheng, Hao; Teng, Xueying; Yan, Liping

    2018-04-01

    A laser heterodyne interferometer for angle measurement based on the Faraday effect is proposed. A novel optical configuration, designed by using the orthogonal return method for a linearly polarized beam based on the Faraday effect, guarantees that the measurement beam can return effectively even though an angular reflector has a large lateral displacement movement. The optical configuration and measurement principle are presented in detail. Two verification experiments were performed; the experimental results show that the proposed interferometer can achieve a large lateral displacement tolerance of 7.4 mm and also can realize high precision angle measurement with a large measurement range.

  17. Note: Comparison experimental results of the laser heterodyne interferometer for angle measurement based on the Faraday effect

    NASA Astrophysics Data System (ADS)

    Zhang, Enzheng; Chen, Benyong; Zheng, Hao; Teng, Xueying; Yan, Liping

    2018-04-01

    A laser heterodyne interferometer for angle measurement based on the Faraday effect is proposed. A novel optical configuration, designed by using the orthogonal return method for a linearly polarized beam based on the Faraday effect, guarantees that the measurement beam can return effectively even though an angular reflector has a large lateral displacement movement. The optical configuration and measurement principle are presented in detail. Two verification experiments were performed; the experimental results show that the proposed interferometer can achieve a large lateral displacement tolerance of 7.4 mm and also can realize high precision angle measurement with a large measurement range.

  18. Recent surface displacements in the Upper Rhine Graben — Preliminary results from geodetic networks

    NASA Astrophysics Data System (ADS)

    Fuhrmann, Thomas; Heck, Bernhard; Knöpfler, Andreas; Masson, Frédéric; Mayer, Michael; Ulrich, Patrice; Westerhaus, Malte; Zippelt, Karl

    2013-08-01

    Datasets of the GNSS Upper Rhine Graben Network (GURN) and the national levelling networks in Germany, France and Switzerland are investigated with respect to current surface displacements in the Upper Rhine Graben (URG) area. GURN consists of about 80 permanent GNSS (Global Navigation Satellite Systems) stations. The terrestrial levelling network comprises 1st and 2nd order levelling lines that have been remeasured at intervals of roughly 25 years, starting in 1922. Compared to earlier studies national institutions and private companies made available raw data, allowing for consistent solutions for the URG region. We focussed on the southern and eastern parts of the investigation area. Our preliminary results show that the levelling and GNSS datasets are sensitive to resolve small surface displacement rates down to an order of magnitude of 0.2 mm/a and 0.4 mm/a, respectively. The observed horizontal velocity components for a test region south of Strasbourg, obtained from GNSS coordinate time series, vary around 0.5 mm/a. The results are in general agreement with interseismic strain built-up in a sinistral strike-slip regime. Since the accuracy of the GNSS derived vertical component is insufficient, data of precise levelling networks is used to determine vertical displacement rates. More than 75% of the vertical rates obtained from a kinematic adjustment of 1st order levelling lines in the eastern part of URG vary between - 0.2 mm/a and + 0.2 mm/a, indicating that this region behaves stable. Higher rates up to 0.5 mm/a in a limited region south of Freiburg are in general agreement with active faulting. We conclude that both networks deliver stable results that reflect real surface movements in the URG area. We note, however, that geodetically observed surface displacements generally result from a superposition of different effects, and that a separation in tectonic and non-tectonic processes needs additional information and expertise.

  19. Alternative Solvents and Technologies for Precision Cleaning of Aerospace Components

    NASA Technical Reports Server (NTRS)

    Grandelli, Heather; Maloney, Phillip; DeVor, Robert; Hintze, Paul

    2014-01-01

    Precision cleaning solvents for aerospace components and oxygen fuel systems, including currently used Vertrel-MCA, have a negative environmental legacy, high global warming potential, and have polluted cleaning sites. Thus, alternative solvents and technologies are being investigated with the aim of achieving precision contamination levels of less than 1 mg/sq ft. The technologies being evaluated are ultrasonic bath cleaning, plasma cleaning and supercritical carbon dioxide cleaning.

  20. Nanomaterials for Cancer Precision Medicine.

    PubMed

    Wang, Yilong; Sun, Shuyang; Zhang, Zhiyuan; Shi, Donglu

    2018-04-01

    Medical science has recently advanced to the point where diagnosis and therapeutics can be carried out with high precision, even at the molecular level. A new field of "precision medicine" has consequently emerged with specific clinical implications and challenges that can be well-addressed by newly developed nanomaterials. Here, a nanoscience approach to precision medicine is provided, with a focus on cancer therapy, based on a new concept of "molecularly-defined cancers." "Next-generation sequencing" is introduced to identify the oncogene that is responsible for a class of cancers. This new approach is fundamentally different from all conventional cancer therapies that rely on diagnosis of the anatomic origins where the tumors are found. To treat cancers at molecular level, a recently developed "microRNA replacement therapy" is applied, utilizing nanocarriers, in order to regulate the driver oncogene, which is the core of cancer precision therapeutics. Furthermore, the outcome of the nanomediated oncogenic regulation has to be accurately assessed by the genetically characterized, patient-derived xenograft models. Cancer therapy in this fashion is a quintessential example of precision medicine, presenting many challenges to the materials communities with new issues in structural design, surface functionalization, gene/drug storage and delivery, cell targeting, and medical imaging. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. Note-Taking Quality and Performance on an L2 Academic Listening Test

    ERIC Educational Resources Information Center

    Song, Min-Young

    2012-01-01

    This study investigated the relationships among the quality of L2 test takers' notes evaluated in terms of different levels of information and test takers' performance on open-ended listening tasks tapping into different comprehension subskills. In addition, this study examined the invariance of the structural relationships among the variables…

  2. Distribution and mitigation of higher-order ionospheric effects on precise GNSS processing

    NASA Astrophysics Data System (ADS)

    Hernández-Pajares, Manuel; Aragón-Ángel, Àngela; Defraigne, Pascale; Bergeot, Nicolas; Prieto-Cerdeira, Roberto; García-Rigo, Alberto

    2014-04-01

    Higher-order ionospheric effects (I2+) are one of the main limiting factors in very precise Global Navigation Satellite Systems (GNSS) processing, for applications where millimeter accuracy is demanded. This paper summarizes a comprehensive study of the I2+ effects in range and in GNSS precise products such as receiver position and clock, tropospheric delay, geocenter offset, and GNSS satellite position and clock. All the relevant higher-order contributions are considered: second and third orders, geometric bending, and slant total electron content (dSTEC) bending (i.e., the difference between the STEC for straight and bent paths). Using a realistic simulation with representative solar maximum conditions on GPS signals, both the effects and mitigation errors are analyzed. The usage of the combination of multifrequency L band observations has to be rejected due to its increased noise level. The results of the study show that the main two effects in range are the second-order ionospheric and dSTEC terms, with peak values up to 2 cm. Their combined impacts on the precise GNSS satellite products affects the satellite Z coordinates (up to +1 cm) and satellite clocks (more than ±20 ps). Other precise products are affected at the millimeter level. After correction the impact on all the precise GNSS products is reduced below 5 mm. We finally show that the I2+ impact on a Precise Point Positioning (PPP) user is lower than the current uncertainties of the PPP solutions, after applying consistently the precise products (satellite orbits and clocks) obtained under I2+ correction.

  3. Tumor resection at the pelvis using three-dimensional planning and patient-specific instruments: a case series.

    PubMed

    Jentzsch, Thorsten; Vlachopoulos, Lazaros; Fürnstahl, Philipp; Müller, Daniel A; Fuchs, Bruno

    2016-09-21

    Sarcomas are associated with a relatively high local recurrence rate of around 30 % in the pelvis. Inadequate surgical margins are the most important reason. However, obtaining adequate margins is particularly difficult in this anatomically demanding region. Recently, three-dimensional (3-D) planning, printed models, and patient-specific instruments (PSI) with cutting blocks have been introduced to improve the precision during surgical tumor resection. This case series illustrates these modern 3-D tools in pelvic tumor surgery. The first consecutive patients with 3-D-planned tumor resection around the pelvis were included in this retrospective study at a University Hospital in 2015. Detailed information about the clinical presentation, imaging techniques, preoperative planning, intraoperative surgical procedures, and postoperative evaluation is provided for each case. The primary outcome was tumor-free resection margins as assessed by a postoperative computed tomography (CT) scan of the specimen. The secondary outcomes were precision of preoperative planning and complications. Four patients with pelvic sarcomas were included in this study. The mean follow-up was 7.8 (range, 6.0-9.0) months. The combined use of preoperative planning with 3-D techniques, 3-D-printed models, and PSI for osteotomies led to higher precision (maximal (max) error of 0.4 centimeters (cm)) than conventional 3-D planning and freehand osteotomies (max error of 2.8 cm). Tumor-free margins were obtained where measurable (n = 3; margins were not assessable in a patient with curettage). Two insufficiency fractures were noted postoperatively. Three-dimensional planning as well as the intraoperative use of 3-D-printed models and PSI are valuable for complex sarcoma resection at the pelvis. Three-dimensionally printed models of the patient anatomy may help visualization and precision. PSI with cutting blocks help perform very precise osteotomies for adequate resection margins.

  4. Selection of Fusion Levels Using the Fulcrum Bending Radiograph for the Management of Adolescent Idiopathic Scoliosis Patients with Alternate Level Pedicle Screw Strategy: Clinical Decision-making and Outcomes.

    PubMed

    Samartzis, Dino; Leung, Yee; Shigematsu, Hideki; Natarajan, Deepa; Stokes, Oliver; Mak, Kin-Cheung; Yao, Guanfeng; Luk, Keith D K; Cheung, Kenneth M C

    2015-01-01

    Selecting fusion levels based on the Luk et al criteria for operative management of thoracic adolescent idiopathic scoliosis (AIS) with hook and hybrid systems yields acceptable curve correction and balance parameters; however, it is unknown whether utilizing a purely pedicle screw strategy is effective. Utilizing the fulcrum bending radiographic (FBR) to assess curve flexibility to select fusion levels, the following study assessed the efficacy of pedicle screw fixation with alternate level screw strategy (ALSS) for thoracic AIS. A retrospective study with prospective radiographic data collection/analyses (preoperative, postoperative 1-week and minimum 2-year follow-up) of 28 operative thoracic AIS patients undergoing ALSS was performed. Standing coronal/sagittal and FBR Cobb angles, FBR flexibility, fulcrum bending correction index (FBCI), trunkal shift, radiographic shoulder height (RSH), and list were assessed on x-rays. Fusion level selection was based on the Luk et al criteria and compared to conventional techniques. In the primary curve, the mean preoperative and postoperative 1 week and last follow-up standing coronal Cobb angles were 59.9, 17.2 and 20.0 degrees, respectively. Eighteen patients (64.3%) had distal levels saved (mean: 1.6 levels) in comparison to conventional techniques. Mean immediate and last follow-up FBCIs were 122.6% and 115.0%, respectively. Sagittal alignment did not statistically differ between any assessment intervals (p>0.05). A decrease in trunkal shift was noted from preoperative to last follow-up (p = 0.003). No statistically significant difference from preoperative to last follow-up was noted in RSH and list (p>0.05). No "add-on" of other vertebra or decompensation was noted and all patients achieved fusion. This is the first report to note that using the FBR for decision-making in selecting fusion levels in thoracic AIS patients undergoing management with pedicle screw constructs (e.g. ALSS) is a cost-effective strategy that can achieve clinically-relevant deformity correction that is maintained and without compromising fusion levels.

  5. Estimating annual suspended-sediment loads in the northern and central Appalachian Coal region

    USGS Publications Warehouse

    Koltun, G.F.

    1985-01-01

    Multiple-regression equations were developed for estimating the annual suspended-sediment load, for a given year, from small to medium-sized basins in the northern and central parts of the Appalachian coal region. The regression analysis was performed with data for land use, basin characteristics, streamflow, rainfall, and suspended-sediment load for 15 sites in the region. Two variables, the maximum mean-daily discharge occurring within the year and the annual peak discharge, explained much of the variation in the annual suspended-sediment load. Separate equations were developed employing each of these discharge variables. Standard errors for both equations are relatively large, which suggests that future predictions will probably have a low level of precision. This level of precision, however, may be acceptable for certain purposes. It is therefore left to the user to asses whether the level of precision provided by these equations is acceptable for the intended application.

  6. Medical decision making: guide to improved CPT coding.

    PubMed

    Holt, Jim; Warsy, Ambreen; Wright, Paula

    2010-04-01

    The Current Procedural Terminology (CPT) coding system for office visits, which has been in use since 1995, has not been well studied, but it is generally agreed that the system contains much room for error. In fact, the available literature suggests that only slightly more than half of physicians will agree on the same CPT code for a given visit, and only 60% of professional coders will agree on the same code for a particular visit. In addition, the criteria used to assign a code are often related to the amount of written documentation. The goal of this study was to evaluate two novel methods to assess if the most appropriate CPT code is used: the level of medical decision making, or the sum of all problems mentioned by the patient during the visit. The authors-a professional coder, a residency faculty member, and a PGY-3 family medicine resident-reviewed 351 randomly selected visit notes from two residency programs in the Northeast Tennessee region for the level of documentation, the level of medical decision making, and the total number of problems addressed. The authors assigned appropriate CPT codes at each of those three levels. Substantial undercoding occurred at each of the three levels. Approximately 33% of visits were undercoded based on the written documentation. Approximately 50% of the visits were undercoded based on the level of documented medical decision making. Approximately 80% of the visits were undercoded based on the total number of problems which the patient presented during the visit. Interrater agreement was fair, and similar to that noted in other coding studies. Undercoding is not only common in a family medicine residency program but it also occurs at levels that would not be evident from a simple audit of the documentation on the visit note. Undercoding also occurs from not exploring problems mentioned by the patient and not documenting additional work that was performed. Family physicians may benefit from minor alterations in their documentation of office visit notes.

  7. Cortical Sensitivity to Guitar Note Patterns: EEG Entrainment to Repetition and Key.

    PubMed

    Bridwell, David A; Leslie, Emily; McCoy, Dakarai Q; Plis, Sergey M; Calhoun, Vince D

    2017-01-01

    Music is ubiquitous throughout recent human culture, and many individual's have an innate ability to appreciate and understand music. Our appreciation of music likely emerges from the brain's ability to process a series of repeated complex acoustic patterns. In order to understand these processes further, cortical responses were measured to a series of guitar notes presented with a musical pattern or without a pattern. ERP responses to individual notes were measured using a 24 electrode Bluetooth mobile EEG system (Smarting mBrainTrain) while 13 healthy non-musicians listened to structured (i.e., within musical keys and with repetition) or random sequences of guitar notes for 10 min each. We demonstrate an increased amplitude to the ERP that appears ~200 ms to notes presented within the musical sequence. This amplitude difference between random notes and patterned notes likely reflects individual's cortical sensitivity to guitar note patterns. These amplitudes were compared to ERP responses to a rare note embedded within a stream of frequent notes to determine whether the sensitivity to complex musical structure overlaps with the sensitivity to simple irregularities reflected in traditional auditory oddball experiments. Response amplitudes to the negative peak at ~175 ms are statistically correlated with the mismatch negativity (MMN) response measured to a rare note presented among a series of frequent notes (i.e., in a traditional oddball sequence), but responses to the subsequent positive peak at ~200 do not show a statistical relationship with the P300 response. Thus, the sensitivity to musical structure identified to 4 Hz note patterns appears somewhat distinct from the sensitivity to statistical regularities reflected in the traditional "auditory oddball" sequence. Overall, we suggest that this is a promising approach to examine individual's sensitivity to complex acoustic patterns, which may overlap with higher level cognitive processes, including language.

  8. Technical Note for 8D Likelihood Effective Higgs Couplings Extraction Framework in the Golden Channel

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, Yi; Di Marco, Emanuele; Lykken, Joe

    2014-10-17

    In this technical note we present technical details on various aspects of the framework introduced in arXiv:1401.2077 aimed at extracting effective Higgs couplings in themore » $$h\\to 4\\ell$$ `golden channel'. Since it is the primary feature of the framework, we focus in particular on the convolution integral which takes us from `truth' level to `detector' level and the numerical and analytic techniques used to obtain it. We also briefly discuss other aspects of the framework.« less

  9. Molecular Nanotechnology and Space Settlement

    NASA Technical Reports Server (NTRS)

    Globus, Al; Saini, Subhash (Technical Monitor)

    1998-01-01

    Atomically precise manipulation of matter is becoming increasingly common in laboratories around the world. As this control moves into aerospace systems, huge improvements in computers, high-strength materials, and other systems are expected. For example, studies suggest that it may be possible to build: 10(exp 18) MIPS computers, 10(exp 15) bytes/sq cm write once memory, $153-412/kg-of-cargo single- stage-to-orbit launch vehicles and active materials which sense their environment and react intelligently. All of NASA's enterprises should benefit significantly from molecular nanotechnology. Although the time may be measured in decades and the precise path to molecular nanotechnology is unclear, all paths (diamondoid, fullerene, self-assembly, biomolecular, etc.) will require very substantial computation. This talk will discuss fullerene nanotechnology and early work on hypothetical active materials consisting of large numbers of identical machines. The speaker will also discuss aerospace applications, particularly missions leading to widespread space settlement (e.g., small near-Earth - object retrieval). It is interesting to note that control of the tiny - individual atoms and molecules - may lead to colonization of the huge -first the solar system, then the galaxy.

  10. Technical note: unsafe rectal temperature measurements due to delayed warming of the thermocouple by using a condom. An issue concerning the estimation of the postmortem interval by using Henßge's nomogram.

    PubMed

    Krap, Tristan; Meurs, Joris; Boertjes, Janine; Duijst, Wilma

    2016-03-01

    In some cases, in the Netherlands, an additional layer is being added to the thermocouple, used to measure the rectal temperature in medicolegal death investigations. Because of this deviation from the standard method, questions arose regarding the accuracy and precision of the measured temperature. Therefore, a cooling experiment was carried out on a round body made of agar with an average thermal conductivity of 0.454 W/(m °C) while measuring the temperature with and without an additional layer around the thermocouple for three different starting temperatures: 36, 30, and 27 °C. The results show a significant difference between the measured values for the first 5 min when comparing with and without the additional layer. Further, a decrease in precision is present within the first minutes when using an additional layer. Therefore, it is concluded that it is best to measure the rectal temperature without an additional layer around the thermocouple and caution should be taken when measuring with an additional layer.

  11. Computer-assisted neurosurgical navigational system for transsphenoidal surgery--technical note.

    PubMed

    Onizuka, M; Tokunaga, Y; Shibayama, A; Miyazaki, H

    2001-11-01

    Transsphenoidal surgery carries the risk of carotid artery injury even for very experienced neurosurgeons. The computer-assisted neurosurgical (CANS) navigational system was used to obtain more precise guidance, based on the axial and coronal images during the transsphenoidal approach for nine pituitary adenomas. The CANS navigator consists of a three-dimensional digitizer, a computer, and a graphic unit, which utilizes electromagnetic coupling technology to detect the spatial position of a suction tube attached to a magnetic sensor. Preoperatively, the magnetic resonance images are transferred and stored in the computer and the tip of the suction tube is shown on a real-time basis superimposed on the preoperative images. The CANS navigation system correctly displayed the surgical orientation and provided localization in all nine patients. No intraoperative complications were associated with the use of this system. However, outflow of cerebrospinal fluid during tumor removal may affect the accuracy, so the position of the probe when the tumor is removed must be accurately determined. The CANS navigator enables precise localization of the suction tube during the transsphenoidal approach and allows safer and less-invasive surgery.

  12. CONFERENCE NOTE: European Optical Society, Topical Meeting Optical Metrology and Nanotechnology, Engelberg, Switzerland, 27 30 March 1994

    NASA Astrophysics Data System (ADS)

    1993-01-01

    This meeting, organized by the Paul Scherrer Institute's Department of Applied Solid State Physics, will be held from 27 30 March 1994 at the Hotel Regina-Titlis, Engelberg, Switzerland. The aim is to bring together scientists from two important fields of current research and increasing industrial relevance. Optical metrology is a traditional discipline of applied optics which reached the nanometre scale a long time ago. Nanotechnology is setting new limits and represents a major challenge to metrology, as well as offering new opportunities to optics. The meeting is intended to help define a common future for optical metrology and nanotechnology. Topics to be covered include: nanometre position control and measuring techniques ultrahigh precision interferometry scanning probe microscopy (AFM, SNOM, etc.) surface modification by scanning probe methods precision surface fabrication and characterization nanolithography micro-optics, diffractive optics components, including systems and applications subwavelength optical structures synthetic optical materials structures and technologies for X-ray optics. For further information please contact: Jens Gobrecht (Secretary), Paul Scherrer Institute, CH-5232 Villigen-PSI, Switzerland.Tel. (41)56992529; Fax (41) 5698 2635.

  13. Diagnostic imaging learning resources evaluated by students and recent graduates.

    PubMed

    Alexander, Kate; Bélisle, Marilou; Dallaire, Sébastien; Fernandez, Nicolas; Doucet, Michèle

    2013-01-01

    Many learning resources can help students develop the problem-solving abilities and clinical skills required for diagnostic imaging. This study explored veterinary students' perceptions of the usefulness of a variety of learning resources. Perceived resource usefulness was measured for different levels of students and for academic versus clinical preparation. Third-year (n=139) and final (fifth) year (n=105) students and recent graduates (n=56) completed questionnaires on perceived usefulness of each resource. Resources were grouped for comparison: abstract/low complexity (e.g., notes, multimedia presentations), abstract/high complexity (e.g., Web-based and film case repositories), concrete/low complexity (e.g., large-group "clicker" workshops), and concrete/high complexity (e.g., small-group interpretation workshops). Lower-level students considered abstract/low-complexity resources more useful for academic preparation and concrete resources more useful for clinical preparation. Higher-level students/recent graduates also considered abstract/low-complexity resources more useful for academic preparation. For all levels, lecture notes were considered highly useful. Multimedia slideshows were an interactive complement to notes. The usefulness of a Web-based case repository was limited by accessibility problems and difficulty. Traditional abstract/low-complexity resources were considered useful for more levels and contexts than expected. Concrete/high-complexity resources need to better represent clinical practice to be considered more useful for clinical preparation.

  14. Enhanced sensitivity for Os isotope ratios by magnetic sector ICP-MS with a capacitive decoupling Pt guard electrode.

    PubMed

    Townsend, A T

    2000-08-01

    A magnetic sector ICP-MS with enhanced sensitivity was used to measure Os isotope ratios in solutions of low Os concentration (approximately 1 ng g(-1) or less). Ratios with 192Os as the basis were determined, while the geologically useful 187Os/188Os ratio was also measured. Sample introduction was via the traditional nebuliser-spray chamber method. A capacitive decoupling Pt shield torch was developed "in-house" and was found to increase Os signals by approximately 5 x under "moderate" plasma conditions (1050 W) over that found during normal operation (1250 W). Sensitivity using the guard electrode for 192Os was approximately 250-350,000 counts s(-1) per ng g(-1) Os. For a I ng g(-1) Os solution with no guard electrode, precisions of the order of 0.2-0.3% (189Os/192Os and 190Os/192Os) to approximately 1% or greater (186Os/192Os, 187Os/192Os and 187Os/188Os) were found (values as 1 sigma for n = 10). With the guard electrode in use, ratio precisions were found to improve to 0.2 to 0.8%. The total amount of Os used in the acquisition of this data was approximately 2.5 ng per measurement per replicate. At the higher concentration of 10 ng g(-1), precisions of the order of 0.15-0.3% were measured (for all ratios), irrespective of whether the shield torch was used. Ratio accuracy was confirmed by comparison with independently obtained NTIMS data. For both Os concentrations considered, the improvement in precision offered by the guard electrode (if any) was small in comparison to calculated theoretical values based on Poisson counting statistics, suggesting noise contributions from other sources (such as the sample introduction system, plasma flicker etc). At lower Os concentrations (to 100 pg g(-1)) no appreciable loss of ratio accuracy was observed, although as expected based on counting statistics, poorer precisions of the order of 0.45-3% (1 sigma, n = 5) were noted. Re was found to have a detrimental effect on the precision of Os ratios involving 187Os, indicating that separation of Re and Os samples is a necessary pre-requisite for highly accurate and precise Os isotope ratio measurements.

  15. Mind Your Composition: Clinical validation of Samsung's pocket-based bioelectrical impedance analyzers may increase consumer interest in personal health management.

    PubMed

    Bhagat, Yusef A; Kim, Insoo; Choi, Ahyoung; Kim, Justin Younghyun; Jo, Seongwook; Cho, Jaegeol

    2015-01-01

    When asked about our weight, most of us can name a figure based on prior knowledge. And while stepping on a scale gives us the ability to know that exact number and track it routinely, it does not provide insights into our body?s composition. This, at the basic level, refers to proportions of fat and lean or fat-free mass (FFM) that comprise the human body. Conventionally, the body mass index (BMI), which is the ratio of body weight in kilograms to the square of its height in meters, and anthropometric parameters like waist circumference, waist-to-hip ratio, and skinfold thickness have been used to estimate the level of fatness. In fact, BMI is the de facto marker for stratifying individuals into underweight (<18.5 kg/m2), normal (18.5-24.9 kg/m2), overweight (25-29.9 kg/m2), and obese (>30 kg/m2) categories. Nonetheless, these metrics are limited in precisely characterizing individuals by percentages of body fat and muscle mass, particularly in epidemiological studies where these proportions vary across age, sex, and ethnic groups. Of note is also how, solely on the basis of BMI, a physically fit individual may be classified as overweight due to having a higher proportion of lean body mass, which outweighs fat. This highlights the importance of body composition in weight tracking and management.

  16. Analysis of usage and associated cost of external fixators at an urban level 1 trauma centre.

    PubMed

    Chaus, George W; Dukes, Chase; Hak, David J; Mauffrey, Cyril; Mark Hammerberg, E

    2014-10-01

    To determine the usage, indication, duration, and cost associated with external fixation usage. Additionally, to show the significant cost associated with external fixator use and reinvigorate discussions on external fixator reuse. A retrospective review of a prospectively gathered trauma database was undertaken to identify all patients treated with external fixation frames for pelvic and lower extremity injuries between September 2007 and July 2010. We noted the indications for frame use, and we determined the average duration of external fixation for each indication. The cost of each frame was calculated from implant records. 341 lower extremity and pelvic fractures were treated with external fixation frames during the study period. Of these, 92% were used as temporary external fixation. The average duration of temporary external fixation was 10.5 days. The cost of external fixation frame components was $670,805 per year. The average cost per external fixation frame was $5900. The majority of external fixators are intended as temporary frames, in place for a limited period of time prior to definitive fixation of skeletal injuries. As such, most frames are not intended to withstand physiologic loads, nor are they expected provide a precise maintenance of reduction. Given the considerable expense associated with external fixation frame components, the practice of purchasing external fixation frame components as disposable "single-use" items appears to be somewhat wasteful. Level II. Copyright © 2014 Elsevier Ltd. All rights reserved.

  17. Thermospheric density and wind retrieval from Swarm observations

    NASA Astrophysics Data System (ADS)

    Visser, Pieter; Doornbos, Eelco; van den IJssel, Jose; Teixeira da Encarnação, João

    2013-11-01

    The three-satellite ESA Swarm mission aims at mapping the Earth's global geomagnetic field at unprecedented spatial and temporal resolution and precision. Swarm also aims at observing thermospheric density and possibly horizontal winds. Precise orbit determination (POD) and Thermospheric Density and Wind (TDW) chains form part of the Swarm Constellation and Application Facility (SCARF), which will provide the so-called Level 2 products. The POD and TDW chains generate the orbit, accelerometer calibration, and thermospheric density and wind Level 2 products. The POD and TDW chains have been tested with data from the CHAMP and GRACE missions, indicating that a 3D orbit precision of about 10 cm can be reached. In addition, POD allows to determine daily accelerometer bias and scale factor values with a precision of around 10-15 nm/s2 and 0.01-0.02, respectively, for the flight direction. With these accelerometer calibration parameter values, derived thermospheric density is consistent at the 9-11% level (standard deviation) with values predicted by models (taking into account that model values are 20-30% higher). The retrieval of crosswinds forms part of the processing chain, but will be challenging. The Swarm observations will be used for further developing and improving density and wind retrieval algorithms.

  18. The Use of Scale-Dependent Precision to Increase Forecast Accuracy in Earth System Modelling

    NASA Astrophysics Data System (ADS)

    Thornes, Tobias; Duben, Peter; Palmer, Tim

    2016-04-01

    At the current pace of development, it may be decades before the 'exa-scale' computers needed to resolve individual convective clouds in weather and climate models become available to forecasters, and such machines will incur very high power demands. But the resolution could be improved today by switching to more efficient, 'inexact' hardware with which variables can be represented in 'reduced precision'. Currently, all numbers in our models are represented as double-precision floating points - each requiring 64 bits of memory - to minimise rounding errors, regardless of spatial scale. Yet observational and modelling constraints mean that values of atmospheric variables are inevitably known less precisely on smaller scales, suggesting that this may be a waste of computer resources. More accurate forecasts might therefore be obtained by taking a scale-selective approach whereby the precision of variables is gradually decreased at smaller spatial scales to optimise the overall efficiency of the model. To study the effect of reducing precision to different levels on multiple spatial scales, we here introduce a new model atmosphere developed by extending the Lorenz '96 idealised system to encompass three tiers of variables - which represent large-, medium- and small-scale features - for the first time. In this chaotic but computationally tractable system, the 'true' state can be defined by explicitly resolving all three tiers. The abilities of low resolution (single-tier) double-precision models and similar-cost high resolution (two-tier) models in mixed-precision to produce accurate forecasts of this 'truth' are compared. The high resolution models outperform the low resolution ones even when small-scale variables are resolved in half-precision (16 bits). This suggests that using scale-dependent levels of precision in more complicated real-world Earth System models could allow forecasts to be made at higher resolution and with improved accuracy. If adopted, this new paradigm would represent a revolution in numerical modelling that could be of great benefit to the world.

  19. The Optimum Level of Argumentativeness for Employed Women.

    ERIC Educational Resources Information Center

    Schullery, Nancy M.

    1998-01-01

    Examines the relationship between argumentativeness and women's supervisory level in organizations. Finds no simple relationship between supervisory level and argumentativeness for women, but indicates that moderation in argumentativeness increases with supervisory level. Notes implications for pedagogy: would-be female executives should be…

  20. Surface Magnetic Field Strengths: New Tests of Magnetoconvective Models of M Dwarfs

    NASA Astrophysics Data System (ADS)

    MacDonald, James; Mullan, D. J.

    2014-05-01

    Precision modeling of M dwarfs has become worthwhile in recent years due to the increasingly precise values of masses and radii which can be obtained from eclipsing binary studies. In a recent paper, Torres has identified four prime M dwarf pairs with the most precise empirical determinations of masses and radii. The measured radii are consistently larger than standard stellar models predict by several percent. These four systems potentially provide the most challenging tests of precision evolutionary models of cool dwarfs at the present time. We have previously modeled M dwarfs in the context of a criterion due to Gough & Tayler in which magnetic fields inhibit the onset of convection according to a physics-based prescription. In the present paper, we apply our magnetoconvective approach to the four prime systems in the Torres list. Going a step beyond what we have already modeled in CM Dra (one of the four Torres systems), we note that new constraints on magnetoconvective models of M dwarfs are now available from empirical estimates of magnetic field strengths on the surfaces of these stars. In the present paper, we consider how well our magnetoconvective models succeed when confronted with this new test of surface magnetic field strengths. Among the systems listed by Torres, we find that plausible magnetic models work well for CM Dra, YY Gem, and CU Cnc. (The fourth system in Torres's list does not yet have enough information to warrant magnetic modeling.) Our magnetoconvection models of CM Dra, YY Gem, and CU Cnc yield predictions of the magnetic fluxes on the stellar surface which are consistent with the observed correlation between magnetic flux and X-ray luminosity.

  1. Surface magnetic field strengths: New tests of magnetoconvective models of M dwarfs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    MacDonald, James; Mullan, D. J., E-mail: jimmacd@udel.edu, E-mail: mullan@udel.edu

    2014-05-20

    Precision modeling of M dwarfs has become worthwhile in recent years due to the increasingly precise values of masses and radii which can be obtained from eclipsing binary studies. In a recent paper, Torres has identified four prime M dwarf pairs with the most precise empirical determinations of masses and radii. The measured radii are consistently larger than standard stellar models predict by several percent. These four systems potentially provide the most challenging tests of precision evolutionary models of cool dwarfs at the present time. We have previously modeled M dwarfs in the context of a criterion due to Goughmore » and Tayler in which magnetic fields inhibit the onset of convection according to a physics-based prescription. In the present paper, we apply our magnetoconvective approach to the four prime systems in the Torres list. Going a step beyond what we have already modeled in CM Dra (one of the four Torres systems), we note that new constraints on magnetoconvective models of M dwarfs are now available from empirical estimates of magnetic field strengths on the surfaces of these stars. In the present paper, we consider how well our magnetoconvective models succeed when confronted with this new test of surface magnetic field strengths. Among the systems listed by Torres, we find that plausible magnetic models work well for CM Dra, YY Gem, and CU Cnc. (The fourth system in Torres's list does not yet have enough information to warrant magnetic modeling.) Our magnetoconvection models of CM Dra, YY Gem, and CU Cnc yield predictions of the magnetic fluxes on the stellar surface which are consistent with the observed correlation between magnetic flux and X-ray luminosity.« less

  2. Meta-analysis of Gaussian individual patient data: Two-stage or not two-stage?

    PubMed

    Morris, Tim P; Fisher, David J; Kenward, Michael G; Carpenter, James R

    2018-04-30

    Quantitative evidence synthesis through meta-analysis is central to evidence-based medicine. For well-documented reasons, the meta-analysis of individual patient data is held in higher regard than aggregate data. With access to individual patient data, the analysis is not restricted to a "two-stage" approach (combining estimates and standard errors) but can estimate parameters of interest by fitting a single model to all of the data, a so-called "one-stage" analysis. There has been debate about the merits of one- and two-stage analysis. Arguments for one-stage analysis have typically noted that a wider range of models can be fitted and overall estimates may be more precise. The two-stage side has emphasised that the models that can be fitted in two stages are sufficient to answer the relevant questions, with less scope for mistakes because there are fewer modelling choices to be made in the two-stage approach. For Gaussian data, we consider the statistical arguments for flexibility and precision in small-sample settings. Regarding flexibility, several of the models that can be fitted only in one stage may not be of serious interest to most meta-analysis practitioners. Regarding precision, we consider fixed- and random-effects meta-analysis and see that, for a model making certain assumptions, the number of stages used to fit this model is irrelevant; the precision will be approximately equal. Meta-analysts should choose modelling assumptions carefully. Sometimes relevant models can only be fitted in one stage. Otherwise, meta-analysts are free to use whichever procedure is most convenient to fit the identified model. © 2018 The Authors. Statistics in Medicine Published by John Wiley & Sons Ltd.

  3. Precision manufacturing for clinical-quality regenerative medicines.

    PubMed

    Williams, David J; Thomas, Robert J; Hourd, Paul C; Chandra, Amit; Ratcliffe, Elizabeth; Liu, Yang; Rayment, Erin A; Archer, J Richard

    2012-08-28

    Innovations in engineering applied to healthcare make a significant difference to people's lives. Market growth is guaranteed by demographics. Regulation and requirements for good manufacturing practice-extreme levels of repeatability and reliability-demand high-precision process and measurement solutions. Emerging technologies using living biological materials add complexity. This paper presents some results of work demonstrating the precision automated manufacture of living materials, particularly the expansion of populations of human stem cells for therapeutic use as regenerative medicines. The paper also describes quality engineering techniques for precision process design and improvement, and identifies the requirements for manufacturing technology and measurement systems evolution for such therapies.

  4. Trueness, Precision, and Detectability for Sampling and Analysis of Organic Species in Airborne Particulate Matter

    EPA Science Inventory

    Recovery. precision, limits of detection and quantitation, blank levels, calibration linearity, and agreement with certified reference materials were determined for two classes of organic components of airborne particulate matter, polycyclic aromatic hydrocarbons and hopanes usin...

  5. Height Connections and Land Uplift Rates in West-Estonian Archipelago

    NASA Astrophysics Data System (ADS)

    Jürgenson, H.; Liibusk, A.; Kall, T.

    2012-04-01

    Land uplift rates are largest in the western part of Estonia. The uplift is due to post-glacial rebound. In 2001-2011, the Estonian national high-precision levelling network was completely renewed and levelled. This was the third precise levelling campaign in the re-gion. The first one had taken place before the Second World War and the second one in the 1950s. The Estonian mainland was connected with the two largest islands (Saaremaa and Hiiumaa) in the west-Estonian archipelago using the water level monitoring (hydrody-namic levelling) method. Three pairs of automatic tide gauges were installed on opposite coasts of each waterway. The tide gauges were equipped with piezoresistive pressure sen-sors. This represented the first use of such kind of equipment in Estonia. The hydrodynamic levelling series span up to two calendar years. Nevertheless, the obtained hydrodynamic levelling results need to be additionally verified using alternative geodetic methods. The obtained results were compared with the previous high-precision levelling data from the 1960s and 1970s. As well, the new Estonian gravimetric geoid model and the GPS survey were used for GPS-levelling. All the three methods were analyzed, and the preliminary results coincided within a 1-2 cm margin. Additionally, the tide gauges on the mainland and on both islands were connected using high-precision levelling. In this manner, three hydrodynamic and three digital levelling height differences formed a closed loop with the length of 250 km. The closing error of the loop was less than 1 cm. Finally, the Fennoscandian post-glacial rebound was determined from repeated levelling as well as from repeated GPS survey. The time span between the two campaigns of the first-order GPS survey was almost 13 years. According to new calculations, the relative land uplift rates within the study area reached up to +2 mm/year. This is an area with a rela-tively small amount of input data for the Nordic models. In addition, a comparison with the Fennoscandian land uplift model NKG2005LU is presented. The results coincided with this model within a 1-mm range. Keywords: hydrodynamic levelling, post-glacial land uplift, GPS-levelling, West-Estonian archipelago.

  6. Spatial Patterns and Sequential Sampling Plans for Predators of Aphis glycines (Hemiptera: Aphididae) in Minnesota Soybean.

    PubMed

    Tran, Anh K; Koch, Robert L

    2017-06-01

    The soybean aphid, Aphis glycines Matsumura, is an economically important soybean pest. Many studies have demonstrated that predatory insects are important in suppressing A. glycines population growth. However, to improve the utilization of predators in A. glycines management, sampling plans need to be developed and validated for predators. Aphid predators were sampled in soybean fields near Rosemount, Minnesota, from 2006-2007 and 2013-2015 with sample sizes of 20-80 plants. Sampling plans were developed for Orius insidiosus (Say), Harmonia axyridis (Pallas), and all aphidophagous Coccinellidae species combined. Taylor's power law parameters from the regression of log variance versus log mean suggested aggregated spatial patterns for immature and adult stages combined for O. insidiosus, H. axyridis, and Coccinellidae in soybean fields. Using the parameters from Taylor's power law and Green's method, sequential fixed-precision sampling plans were developed to estimate the density for each predator taxon at desired precision levels of 0.10 and 0.25. To achieve a desired precision of 0.10 and 0.25, the average sample number (ASN) ranged from 398-713 and 64-108 soybean plants, respectively, for all species. Resulting ASNs were relatively large and assumed impractical for most purposes; therefore, the desired precision levels were adjusted to determine the level of precision associated with a more practical ASN. Final analysis indicated an ASN of 38 soybean plants provided precision of 0.32-0.40 for the predators. Development of sampling plans should provide guidance for improved estimation of predator densities for A. glycines pest management programs and for research purposes. © The Authors 2017. Published by Oxford University Press on behalf of Entomological Society of America. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  7. Active Remote Sensing of Natural Resources: Course Notes. Science Series No. 5. Final Technical Report.

    ERIC Educational Resources Information Center

    Maxwell, Eugene L.

    Presented is a portion of a research project which developed materials for teaching remote sensing of natural resources on an interdisciplinary basis at the graduate level. This volume contains notes developed for a course in active remote sensing. It is concerned with those methods or systems which generate the electromagnetic energy…

  8. The Effect of Note-Taking on University Students' Listening Comprehension of Lectures

    ERIC Educational Resources Information Center

    Kiliçkaya, Ferit; Çokal Karadas, Derya

    2009-01-01

    The study investigated the effect of note-taking on comprehension of lectures by 44 undergraduate EFL students who are in the first year of their undergraduate level in the Department of Foreign Language Education in Middle East Technical University. The participants were divided into two groups, namely experimental and control groups. The…

  9. 28 CFR Appendix A to Part 35 - Guidance to Revisions to ADA Regulation on Nondiscrimination on the Basis of Disability in State...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... communicated effectively using handwritten notes. One major advocacy organization, for example, noted that the... example, blood work for routine lab tests or regular allergy shots. Video Interpreting Services... or combustion engines. One commenter suggested using exhaust level as the determinant. Although there...

  10. 28 CFR Appendix A to Part 35 - Guidance to Revisions to ADA Regulation on Nondiscrimination on the Basis of Disability in State...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... communicated effectively using handwritten notes. One major advocacy organization, for example, noted that the... example, blood work for routine lab tests or regular allergy shots. Video Interpreting Services... or combustion engines. One commenter suggested using exhaust level as the determinant. Although there...

  11. 28 CFR Appendix A to Part 35 - Guidance to Revisions to ADA Regulation on Nondiscrimination on the Basis of Disability in State...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... communicated effectively using handwritten notes. One major advocacy organization, for example, noted that the... example, blood work for routine lab tests or regular allergy shots. Video Interpreting Services... or combustion engines. One commenter suggested using exhaust level as the determinant. Although there...

  12. 28 CFR Appendix A to Part 35 - Guidance to Revisions to ADA Regulation on Nondiscrimination on the Basis of Disability in State...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... communicated effectively using handwritten notes. One major advocacy organization, for example, noted that the... example, blood work for routine lab tests or regular allergy shots. Video Interpreting Services... or combustion engines. One commenter suggested using exhaust level as the determinant. Although there...

  13. A Spreadsheet Tool for Learning the Multiple Regression F-Test, T-Tests, and Multicollinearity

    ERIC Educational Resources Information Center

    Martin, David

    2008-01-01

    This note presents a spreadsheet tool that allows teachers the opportunity to guide students towards answering on their own questions related to the multiple regression F-test, the t-tests, and multicollinearity. The note demonstrates approaches for using the spreadsheet that might be appropriate for three different levels of statistics classes,…

  14. Please Take Note: Teaching Low Level Notetaking.

    ERIC Educational Resources Information Center

    Stanley, Karen

    An introductory course in notetaking for low intermediate students of English as a second language (ESL) is described. The course is designed to give practice in notetaking techniques to college-bound ESI students before they are required to take notes with a competence equal to that of native speakers. The class begins with a discussion of common…

  15. Electrical injuries due to railway high tension cables.

    PubMed

    Reichl, M; Kay, S

    1985-08-01

    We have noted a large number of young boys being admitted to our Unit with burns due to railway high tension cables. On review of these cases we have noted: most of the burns were due to arcing, there is a high level of ignorance among the population at risk. We propose some ways of preventing these injuries.

  16. The Chronic Underrepresentation of African Americans in Medicine. ETS Policy Notes. Volume 12, Number 1, Winter 2004

    ERIC Educational Resources Information Center

    Barton, Paul E.

    2004-01-01

    This issue of "ETS Policy Notes" examines the underrepresentation of African Americans in medical school, focusing on trends in enrollment and graduation at all levels of education. African American college students' interest in the medical profession, their pursuit of degrees in biological sciences, and the growing gender differences in…

  17. Ritual Associated with Participation in Physical Education: The Power of Excuse Notes

    ERIC Educational Resources Information Center

    Lamb, Penny

    2014-01-01

    Physical education (PE) is steeped in history, tradition and ritual. The accepted tradition of excuse notes allowing pupils to self-exempt from lessons is one such ritual associated with the subject in schools. This paper explores the impact of this phenomenon, focusing on participation and engagement levels within PE lessons. Data was collected…

  18. Expansion of a physical function item bank and development of an abbreviated form for clinical research.

    PubMed

    Bode, Rita K; Lai, Jin-shei; Dineen, Kelly; Heinemann, Allen W; Shevrin, Daniel; Von Roenn, Jamie; Cella, David

    2006-01-01

    We expanded an existing 33-item physical function (PF) item bank with a sufficient number of items to enable computerized adaptive testing (CAT). Ten items were written to expand the bank and the new item pool was administered to 295 people with cancer. For this analysis of the new pool, seven poorly performing items were identified for further examination. This resulted in a bank with items that define an essentially unidimensional PF construct, cover a wide range of that construct, reliably measure the PF of persons with cancer, and distinguish differences in self-reported functional performance levels. We also developed a 5-item (static) assessment form ("BriefPF") that can be used in clinical research to express scores on the same metric as the overall bank. The BriefPF was compared to the PF-10 from the Medical Outcomes Study SF-36. Both short forms significantly differentiated persons across functional performance levels. While the entire bank was more precise across the PF continuum than either short form, there were differences in the area of the continuum in which each short form was more precise: the BriefPF was more precise than the PF-10 at the lower functional levels and the PF-10 was more precise than the BriefPF at the higher levels. Future research on this bank will include the development of a CAT version, the PF-CAT.

  19. The Grass Isn’t Always Greener: Perceptions of and Performance on Open-Note Exams

    PubMed Central

    Sato, Brian K.; He, Wenliang; Warschauer, Mark; Kadandale, Pavan

    2015-01-01

    Undergraduate biology education is often viewed as being focused on memorization rather than development of students’ critical-thinking abilities. We speculated that open-note testing would be an easily implemented change that would emphasize higher-order thinking. As open-note testing is not commonly used in the biological sciences and the literature on its effects in biology education is sparse, we performed a comprehensive analysis of this intervention on a primary literature–based exam across three large-enrollment laboratory courses. Although students believed open-note testing would impact exam scores, we found no effect on performance, either overall or on questions of nearly all Bloom’s levels. Open-note testing also produced no advantage when examined under a variety of parameters, including research experience, grade point average, course grade, prior exposure to primary literature–focused laboratory courses, or gender. Interestingly, we did observe small differences in open- and closed-note exam performance and perception for students who experienced open-note exams for an entire quarter. This implies that student preparation or in-test behavior can be altered by exposure to open-note testing conditions in a single course and that ­increased experience may be necessary to truly understand the impact of this intervention. PMID:25828402

  20. 75 FR 63067 - Interpretation of “Children's Product”

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-10-14

    ... a level of sophistication required to operate the locomotives. Additionally, the commenters note... railroad hobbyists, the costs involved, and the level of sophistication required to operate them. Model...

  1. 47. MAIN WAREHOUSE SECOND LEVEL ADDITION Second level was ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    47. MAIN WAREHOUSE - SECOND LEVEL ADDITION Second level was added in 1941. Note the variety of building materials used in the wall: cement, bricks and finally cement blocks, with wood topping the entire wall. - Hovden Cannery, 886 Cannery Row, Monterey, Monterey County, CA

  2. Precision of channel catfish catch estimates using hoop nets in larger Oklahoma reservoirs

    USGS Publications Warehouse

    Stewart, David R.; Long, James M.

    2012-01-01

    Hoop nets are rapidly becoming the preferred gear type used to sample channel catfish Ictalurus punctatus, and many managers have reported that hoop nets effectively sample channel catfish in small impoundments (<200 ha). However, the utility and precision of this approach in larger impoundments have not been tested. We sought to determine how the number of tandem hoop net series affected the catch of channel catfish and the time involved in using 16 tandem hoop net series in larger impoundments (>200 ha). Hoop net series were fished once, set for 3 d; then we used Monte Carlo bootstrapping techniques that allowed us to estimate the number of net series required to achieve two levels of precision (relative standard errors [RSEs] of 15 and 25) at two levels of confidence (80% and 95%). Sixteen hoop net series were effective at obtaining an RSE of 25 with 80% and 95% confidence in all but one reservoir. Achieving an RSE of 15 was often less effective and required 18-96 hoop net series given the desired level of confidence. We estimated that an hour was needed, on average, to deploy and retrieve three hoop net series, which meant that 16 hoop net series per reservoir could be "set" and "retrieved" within a day, respectively. The estimated number of net series to achieve an RSE of 25 or 15 was positively associated with the coefficient of variation (CV) of the sample but not with reservoir surface area or relative abundance. Our results suggest that hoop nets are capable of providing reasonably precise estimates of channel catfish relative abundance and that the relationship with the CV of the sample reported herein can be used to determine the sampling effort for a desired level of precision.

  3. Precision in robotic rectal surgery using the da Vinci Xi system and integrated table motion, a technical note.

    PubMed

    Panteleimonitis, Sofoklis; Harper, Mick; Hall, Stuart; Figueiredo, Nuno; Qureshi, Tahseen; Parvaiz, Amjad

    2017-09-15

    Robotic rectal surgery is becoming increasingly more popular among colorectal surgeons. However, time spent on robotic platform docking, arm clashing and undocking of the platform during the procedure are factors that surgeons often find cumbersome and time consuming. The newest surgical platform, the da Vinci Xi, coupled with integrated table motion can help to overcome these problems. This technical note aims to describe a standardised operative technique of single docking robotic rectal surgery using the da Vinci Xi system and integrated table motion. A stepwise approach of the da Vinci docking process and surgical technique is described accompanied by an intra-operative video that demonstrates this technique. We also present data collected from a prospectively maintained database. 33 consecutive rectal cancer patients (24 male, 9 female) received robotic rectal surgery with the da Vinci Xi during the preparation of this technical note. 29 (88%) patients had anterior resections, and four (12%) had abdominoperineal excisions. There were no conversions, no anastomotic leaks and no mortality. Median operation time was 331 (249-372) min, blood loss 20 (20-45) mls and length of stay 6.5 (4-8) days. 30-day readmission rate and re-operation rates were 3% (n = 1). This standardised technique of single docking robotic rectal surgery with the da Vinci Xi is safe, feasible and reproducible. The technological advances of the new robotic system facilitate the totally robotic single docking approach.

  4. How Can We Mobilize Action to Realize UHC in Asia?

    PubMed

    Akaza, Hideyuki; Kawahara, Norie; Fukuda, Takashi; Horie, Shigeo; Thabrany, Hasbullah; Nozaki, Shinjiro

    2017-11-26

    The 2016 World Cancer Congress, organised by UICC, was held in Paris in November 2016, under the theme “Mobilizing action – Inspiring Change.” As part of Track 4 presentations on the theme of “Strengthening cancer control: optimizing outcomes of health systems,” UICC-Asian Regional Office (UICC-ARO) held a symposium to discuss the issue of mobilizing action to realize UHC in Asia. Introducing the symposium, Hideyuki Akaza noted that universal health coverage (UHC) is included in the Sustainable Development Goals and one of the key issues for achieving UHC will be how to balance patient needs with the economic burden of cancer. Speakers from Japan and Indonesia addressed various issues, including the current status and challenges for medical economic evaluation in Asia, the importance of resource stratification, prospects for precision medicine, and the outlook for cancer control and UHC in developing and emerging countries in Asia. Key issues raised included how to respond to the rising costs of treating cancer as new and increasingly expensive drugs come to the market. Speakers and participants noted that health technology assessment programs are being developed around Asia in order to evaluate the cost-effectiveness of drugs in the face of budgetary constraints within increasingly pressurized national health systems. The importance of screening and early detection was also noted as effective means that have the potential to reduce reliance on expensive drugs for advanced cancers. The symposium was chaired jointly by Hideyuki Akaza and Shinjiro Nozaki (WHO Kobe Centre). Creative Commons Attribution License

  5. High Precision Continuous and Real-Time Measurement of Atmospheric Oxygen Using Cavity Ring-Down Spectroscopy.

    NASA Astrophysics Data System (ADS)

    Kim-Hak, D.; Hoffnagle, J.; Rella, C.; Sun, M.

    2016-12-01

    Oxygen is a major and vital component of the Earth atmosphere representing about 21% of its composition. It is consumed or produced through biochemical processes such as combustion, respiration, and photosynthesis. Although atmospheric oxygen is not a greenhouse gas, it can be used as a top-down constraint on the carbon cycle. The variation observations of oxygen in the atmosphere are very small, in the order of the few ppm's. This presents the main technical challenge for measurement as a very high level of precision is required and only few methods including mass spectrometry, fuel cell, and paramagnetic are capable of overcoming it. Here we present new developments of a high-precision gas analyzer that utilizes the technique of Cavity Ring-Down Spectroscopy to measure oxygen concentration and oxygen isotope. Its compact and ruggedness design combined with high precision and long-term stability allows the user to deploy the instrument in the field for continuous monitoring of atmospheric oxygen level. Measurements have a 1-σ 5-minute averaging precision of 1-2 ppm for O2 over a dynamic range of 0-20%. We will present supplemental data acquired from our 10m tower measurements in Santa Clara, CA.

  6. Precision agriculture in large-scale mechanized farming

    USDA-ARS?s Scientific Manuscript database

    Precision agriculture involves a great deal of technologies and requires additional investments of money and time, but it can be practiced at different levels depending on the specific field and crop conditions and the resources and technology services available to the farmer. If practiced properly,...

  7. The measurement of Earth rotation on a deformable Earth

    NASA Technical Reports Server (NTRS)

    Cannon, W. H.

    1980-01-01

    Until recently, the methods of geodetic positioning on the Earth were limited to a precision of roughly one part in 10 to the 6th power. At this level of precision, the Earth can be regarded as a rigid body since the largest departure of the Earth from rigidity is manifested in the strains of the Earth tides which are of the order of one part in 10 to the 7th power. Long baseline interferometry is expected to routinely provide global positioning to a precision of one part in 10 to the 8th power or better. At this level of precision, all parts of the Earth's surface must be regarded as being, at least potentially, in continual motion relative to the geocenter as a result of a variety of geophysical effects. The general implications of this phenomenon for the theory of the Earth's rotation is discussed. Particular attention is given to the question of the measurement of the 'Earth's rotation vector' on a deformable Earth.

  8. Accuracy of the Precision® point-of-care ketone test examined by liquid chromatography tandem-mass spectrometry (LC-MS/MS) in the same fingerstick sample.

    PubMed

    Janssen, Marcel J W; Hendrickx, Ben H E; Habets-van der Poel, Carin D; van den Bergh, Joop P W; Haagen, Anton A M; Bakker, Jaap A

    2010-12-01

    The Precision(®) (Abbott Diabetes Care) point-of-care biosensor test strips are widely used by patients with diabetes and clinical laboratories for measurement of plasma β-hydroxybutyrate (β-HB) concentrations in capillary blood samples obtained by fingerstick. In the literature, this procedure has been validated only against the enzymatic determination of β-HB in venous plasma, i.e., the method to which the Precision(®) has been calibrated. In this study, the Precision(®) Xceed was compared to a methodologically different and superior procedure: determination of β-HB by liquid chromatography tandem-mass spectrometry (LC-MS/MS) in capillary blood spots. Blood spots were obtained from the same fingerstick sample from out of which Precision(®) measurements were performed. Linearity was tested by adding varying amounts of standard to an EDTA venous whole blood matrix. The Precision(®) was in good agreement with LC-MS/MS within the measuring range of 0.0-6.0 mmol/L (Passing and Bablok regression: slope=1.20 and no significant intercept, R=0.97, n=59). Surprisingly, the Precision(®) showed non-linearity and full saturation at concentrations above 6.0 mmol/L, which were confirmed by a standard addition experiment. Results obtained at the saturation level varied between 3.0 and 6.5 mmol/L. The Precision(®) β-HB test strips demonstrate good comparison with LC-MS/MS. Inter-individual variation around the saturation level, however, is large. Therefore, we advise reporting readings above 3.0 as >3.0 mmol/L. The test is valid for use in the clinically relevant range of 0.0-3.0 mmol/L.

  9. Identification of Nonlinear Micron-Level Mechanics for a Precision Deployable Joint

    NASA Technical Reports Server (NTRS)

    Bullock, S. J.; Peterson, L. D.

    1994-01-01

    The experimental identification of micron-level nonlinear joint mechanics and dynamics for a pin-clevis joint used in a precision, adaptive, deployable space structure are investigated. The force-state mapping method is used to identify the behavior of the joint under a preload. The results of applying a single tension-compression cycle to the joint under a tensile preload are presented. The observed micron-level behavior is highly nonlinear and involves all six rigid body motion degrees-of-freedom of the joint. it is also suggests that at micron levels of motion modelling of the joint mechanics and dynamics must include the interactions between all internal components, such as the pin, bushings, and the joint node.

  10. A proposed time transfer experiment between the USA and the South Pacific

    NASA Technical Reports Server (NTRS)

    Luck, John; Dunkley, John; Armstrong, Tim; Gifford, Guy A.; Landis, Paul; Rasmussen, Scott; Wheeler, Paul J.; Bartholomew, Thomas R.; Stein, Samuel R.

    1992-01-01

    Described here are the concept, architecture and preliminary details of an experiment directed towards providing continuous Ultra High Precision (UHP) time transfer between Washington, DC; Salisbury, SA Australia; Orroral Valley, ACT Australia; and Lower Hutt, New Zealand. A proposed method of distributing UTC(USNO) at a high level of precision to passive users over a broad area of the South Pacific is described. The concept is based on active two-way satellite time transfer from the United States Naval Observatory (USNO) to the proposed USNO Master Clock West (MCW) in Wahiwa, HI at the 1 nanosecond level using active satellite two-way time transfer augmented by Precise Positioning Service (PPS) of the Global Positioning System (GPS). MCW would act as an intermediate transfer/reference station, again linked to Salisbury at the 1 nanosecond level using active satellite two-way time transfer augmented by PPS GPS. From this point, time would be distributed within the region by two methods. The first is an existing TV line sync system using an Australian communications satellite (AUSSAT K1) which is useful to the 20 nanosecond level. The second approach is RF ranging and multilateration between Salisbury, Orroral Observatory, Lower Hutt and the AUSSAT B1 and B2 to be launched in 1992. Orroral Observatory will provide precise laser ranging to the AUSSAT B1/B2 retro reflectors which will reduce ephemeris related time transfer errors to below 1 nanosecond. The corrected position will be transmitted by both the time transfer modem and the existing TV line sync dissemination process. Multilateration has the advantage of being an all weather approach and when used with the laser ranging technique will provide a precise measurement of the propagation path delays. This will result in time transfer performance levels on the order of 10 nanoseconds to passive users in both Australia and New Zealand.

  11. High-precision arithmetic in mathematical physics

    DOE PAGES

    Bailey, David H.; Borwein, Jonathan M.

    2015-05-12

    For many scientific calculations, particularly those involving empirical data, IEEE 32-bit floating-point arithmetic produces results of sufficient accuracy, while for other applications IEEE 64-bit floating-point is more appropriate. But for some very demanding applications, even higher levels of precision are often required. Furthermore, this article discusses the challenge of high-precision computation, in the context of mathematical physics, and highlights what facilities are required to support future computation, in light of emerging developments in computer architecture.

  12. Readability Formulas and User Perceptions of Electronic Health Records Difficulty: A Corpus Study.

    PubMed

    Zheng, Jiaping; Yu, Hong

    2017-03-02

    Electronic health records (EHRs) are a rich resource for developing applications to engage patients and foster patient activation, thus holding a strong potential to enhance patient-centered care. Studies have shown that providing patients with access to their own EHR notes may improve the understanding of their own clinical conditions and treatments, leading to improved health care outcomes. However, the highly technical language in EHR notes impedes patients' comprehension. Numerous studies have evaluated the difficulty of health-related text using readability formulas such as Flesch-Kincaid Grade Level (FKGL), Simple Measure of Gobbledygook (SMOG), and Gunning-Fog Index (GFI). They conclude that the materials are often written at a grade level higher than common recommendations. The objective of our study was to explore the relationship between the aforementioned readability formulas and the laypeople's perceived difficulty on 2 genres of text: general health information and EHR notes. We also validated the formulas' appropriateness and generalizability on predicting difficulty levels of highly complex technical documents. We collected 140 Wikipedia articles on diabetes and 242 EHR notes with diabetes International Classification of Diseases, Ninth Revision code. We recruited 15 Amazon Mechanical Turk (AMT) users to rate difficulty levels of the documents. Correlations between laypeople's perceived difficulty levels and readability formula scores were measured, and their difference was tested. We also compared word usage and the impact of medical concepts of the 2 genres of text. The distributions of both readability formulas' scores (P<.001) and laypeople's perceptions (P=.002) on the 2 genres were different. Correlations of readability predictions and laypeople's perceptions were weak. Furthermore, despite being graded at similar levels, documents of different genres were still perceived with different difficulty (P<.001). Word usage in the 2 related genres still differed significantly (P<.001). Our findings suggested that the readability formulas' predictions did not align with perceived difficulty in either text genre. The widely used readability formulas were highly correlated with each other but did not show adequate correlation with readers' perceived difficulty. Therefore, they were not appropriate to assess the readability of EHR notes. ©Jiaping Zheng, Hong Yu. Originally published in the Journal of Medical Internet Research (http://www.jmir.org), 02.03.2017.

  13. Effects of acute chlorpyrifos exposure on in vivo acetylcholine accumulation in rat striatum

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Karanth, Subramanya; Liu, Jing; Mirajkar, Nikita

    2006-10-01

    This study examined the acute effects of chlorpyrifos (CPF) on cholinesterase inhibition and acetylcholine levels in the striatum of freely moving rats using in vivo microdialysis. Adult, male Sprague-Dawley rats were treated with vehicle (peanut oil, 2 ml/kg) or CPF (84, 156 or 279 mg/kg, sc) and functional signs of toxicity, body weight and motor activity recorded. Microdialysis was conducted at 1, 4 and 7 days after CPF exposure for measurement of acetylcholine levels in striatum. Rats were then sacrificed and the contralateral striatum and diaphragm were collected for biochemical measurements. Few overt signs of cholinergic toxicity were noted inmore » any rats. Body weight gain was significantly affected in the high-dose (279 mg/kg) group only, while motor activity (nocturnal rearing) was significantly reduced in all CPF-treated groups at one day (84 mg/kg) or from 1-4 days (156 and 279 mg/kg) after dosing. Cholinesterase activities in both diaphragm and striatum were markedly inhibited (50-92%) in a time-dependent manner, but there were relatively minimal dose-related changes. In contrast, time- and dose-dependent changes in striatal acetylcholine levels were noted, with significantly higher levels noted in the high-dose group compared to other groups. Maximal increases in striatal acetylcholine levels were observed at 4-7 days after dosing (84 mg/kg, 7-9-fold; 156 mg/kg, 10-13-fold; 279 mg/kg, 35-57-fold). Substantially higher acetylcholine levels were noted when an exogenous cholinesterase inhibitor was included in the perfusion buffer, but CPF treatment-related differences were substantially lower in magnitude under those conditions. The results suggest that marked differences in acetylcholine accumulation can occur with dosages of CPF eliciting relatively similar degrees of cholinesterase inhibition. Furthermore, the minimal expression of classic signs of cholinergic toxicity in the presence of extensive brain acetylcholine accumulation suggests that some compensatory process(es) downstream from synaptic neurotransmitter accumulation limits the expression of toxicity following acute CPF exposure.« less

  14. Role of nitric oxide in the onset of facial nerve palsy by HSV-1 infection.

    PubMed

    Hato, Naohito; Kohno, Hisashi; Yamada, Hiroyuki; Takahashi, Hirotaka; Gyo, Kiyofumi

    2013-12-01

    Although herpes simplex virus type 1 (HSV-1) is a causative agent of Bell palsy, the precise mechanism of the paralysis remains unknown. It is necessary to investigate the pathogenesis and treatment of Bell palsy due to HSV-1 infection. This study elucidated the role of nitric oxide (NO) in the incidence of facial nerve paralysis caused by HSV-1 in mice and to evaluate the possible role of edaravone, a free radical scavenger, in preventing the paralysis. Sixty-two mice served as animal models of Bell palsy in this laboratory study conducted at an academic institution. Levels of NO in the facial nerve were measured using high-performance liquid chromatography and absorption photometry. The incidence of facial palsy was assessed following administration of edaravone immediately after HSV-1 inoculation and daily for 11 days thereafter. The ratio of NO (inoculated side to control side) and incidence of facial palsy. RESULTS Before the onset of facial palsy, no substantial difference in the NO level was noted between the HSV-1-inoculated side and the control side. When facial palsy occurred, usually at 7 days after inoculation, the NO level was significantly higher on the inoculated side than on the control side. Following recovery from the palsy, the high NO level of the inoculated side decreased. No increase in the NO level was observed in animals without transient facial palsy. When edaravone was administered, the incidence of facial palsy decreased significantly. These findings suggest that NO produced by inducible NO synthase in the facial nerve plays an important role in the onset of facial palsy caused by HSV-1 infection, which is considered a causative virus of Bell palsy. Hato and colleagues elucidate the role of nitric oxide in HSV-1–related facial nerve paralysis in mice and evaluate the role of edaravone, a free radical scavenger, in preventing the paralysis.

  15. YouTube as a crowd-generated water level archive.

    PubMed

    Michelsen, N; Dirks, H; Schulz, S; Kempe, S; Al-Saud, M; Schüth, C

    2016-10-15

    In view of the substantial costs associated with classic monitoring networks, participatory data collection methods can be deemed a promising option to obtain complementary data. An emerging trend in this field is social media mining, i.e., harvesting of pre-existing, crowd-generated data from social media. Although this approach is participatory in a broader sense, the users are mostly not aware of their participation in research. Inspired by this novel development, we demonstrate in this study that it is possible to derive a water level time series from the analysis of multiple YouTube videos. As an example, we studied the recent water level rise in Dahl Hith, a Saudi Arabian cave. To do so, we screened 16 YouTube videos of the cave for suitable reference points (e.g., cave graffiti). Then, we visually estimated the distances between these points and the water level and traced their changes over time. To bridge YouTube hiatuses, we considered own photos taken during two site visits. For the time period 2013-2014, we estimate a rise of 9.5m. The fact that this rise occurred at a somewhat constant rate of roughly 0.4m per month points towards a new and permanent water source, possibly two nearby lakes formed from treated sewage effluent. An anomaly in the rising rate is noted for autumn 2013 (1.3m per month). As this increased pace coincides with a cluster of rain events, we deem rapid groundwater recharge along preferential flow paths a likely cause. Despite the sacrifice in precision, we believe that YouTube harvesting may represent a viable option to gather historical water levels in data-scarce settings and that it could be adapted to other environments (e.g., flood extents). In certain areas, it might provide an additional tool for the monitoring toolbox, thereby possibly delivering hydrological data for water resources management. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. Precision Attitude Control for the BETTII Balloon-Borne Interferometer

    NASA Technical Reports Server (NTRS)

    Benford, Dominic J.; Fixsen, Dale J.; Rinehart. Stephen

    2012-01-01

    The Balloon Experimental Twin Telescope for Infrared Interferometry (BETTII) is an 8-meter baseline far-infrared interferometer to fly on a high altitude balloon. Operating at wavelengths of 30-90 microns, BETTII will obtain spatial and spectral information on science targets at angular resolutions down to less than half an arcsecond, a capability unmatched by other far-infrared facilities. This requires attitude control at a level ofless than a tenth of an arcsecond, a great challenge for a lightweight balloon-borne system. We have designed a precision attitude determination system to provide gondola attitude knowledge at a level of 2 milliarcseconds at rates up to 100Hz, with accurate absolute attitude determination at the half arcsecond level at rates of up to 10Hz. A mUlti-stage control system involving rigid body motion and tip-tilt-piston correction provides precision pointing stability to the level required for the far-infrared instrument to perform its spatial/spectral interferometry in an open-loop control. We present key aspects of the design of the attitude determination and control and its development status.

  17. Opportunities for the Cardiovascular Community in the Precision Medicine Initiative.

    PubMed

    Shah, Svati H; Arnett, Donna; Houser, Steven R; Ginsburg, Geoffrey S; MacRae, Calum; Mital, Seema; Loscalzo, Joseph; Hall, Jennifer L

    2016-01-12

    The Precision Medicine Initiative recently announced by President Barack Obama seeks to move the field of precision medicine more rapidly into clinical care. Precision medicine revolves around the concept of integrating individual-level data including genomics, biomarkers, lifestyle and other environmental factors, wearable device physiological data, and information from electronic health records to ultimately provide better clinical care to individual patients. The Precision Medicine Initiative as currently structured will primarily fund efforts in cancer genomics with longer-term goals of advancing precision medicine to all areas of health, and will be supported through creation of a 1 million person cohort study across the United States. This focused effort on precision medicine provides scientists, clinicians, and patients within the cardiovascular community an opportunity to work together boldly to advance clinical care; the community needs to be aware and engaged in the process as it progresses. This article provides a framework for potential involvement of the cardiovascular community in the Precision Medicine Initiative, while highlighting significant challenges for its successful implementation. © 2016 American Heart Association, Inc.

  18. RANKED SET SAMPLING FOR ECOLOGICAL RESEARCH: ACCOUNTING FOR THE TOTAL COSTS OF SAMPLING

    EPA Science Inventory

    Researchers aim to design environmental studies that optimize precision and allow for generalization of results, while keeping the costs of associated field and laboratory work at a reasonable level. Ranked set sampling is one method to potentially increase precision and reduce ...

  19. Classical Electrodynamics: Lecture notes

    NASA Astrophysics Data System (ADS)

    Likharev, Konstantin K.

    2018-06-01

    Essential Advanced Physics is a series comprising four parts: Classical Mechanics, Classical Electrodynamics, Quantum Mechanics and Statistical Mechanics. Each part consists of two volumes, Lecture notes and Problems with solutions, further supplemented by an additional collection of test problems and solutions available to qualifying university instructors. This volume, Classical Electrodynamics: Lecture notes is intended to be the basis for a two-semester graduate-level course on electricity and magnetism, including not only the interaction and dynamics charged point particles, but also properties of dielectric, conducting, and magnetic media. The course also covers special relativity, including its kinematics and particle-dynamics aspects, and electromagnetic radiation by relativistic particles.

  20. Precision and Fast Wavelength Tuning of a Dynamically Phase-Locked Widely-Tunable Laser

    NASA Technical Reports Server (NTRS)

    Numata, Kenji; Chen, Jeffrey R.; Wu, Stewart T.

    2012-01-01

    We report a precision and fast wavelength tuning technique demonstrated for a digital-supermode distributed Bragg reflector laser. The laser was dynamically offset-locked to a frequency-stabilized master laser using an optical phase-locked loop, enabling precision fast tuning to and from any frequencies within a 40-GHz tuning range. The offset frequency noise was suppressed to the statically offset-locked level in less than 40 s upon each frequency switch, allowing the laser to retain the absolute frequency stability of the master laser. This technique satisfies stringent requirements for gas sensing lidars and enables other applications that require such well-controlled precision fast tuning.

  1. Light leptonic new physics at the precision frontier

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Le Dall, Matthias, E-mail: mledall@uvic.ca

    2016-06-21

    Precision probes of new physics are often interpreted through their indirect sensitivity to short-distance scales. In this proceedings contribution, we focus on the question of which precision observables, at current sensitivity levels, allow for an interpretation via either short-distance new physics or consistent models of long-distance new physics, weakly coupled to the Standard Model. The electroweak scale is chosen to set the dividing line between these scenarios. In particular, we find that inverse see-saw models of neutrino mass allow for light new physics interpretations of most precision leptonic observables, such as lepton universality, lepton flavor violation, but not for themore » electron EDM.« less

  2. Education for All: Compensating for Disadvantage in Mexico. Education Notes

    ERIC Educational Resources Information Center

    Patrinos, Harry Anthony; Shapiro, Joseph; Trevino, Jorge Moreno

    2004-01-01

    This note series is intended to summarize lessons learned and key policy findings on the World Bank's work in education.Education for all means learning for all. It means closing the "advantage" gap--making sure that the children of the poor and disadvantaged achieve the same levels of learning as all other children. This is one of the…

  3. Teaching Note--Tweeting Macro Practice: Social Media in the Social Work Classroom

    ERIC Educational Resources Information Center

    Teixeira, Samantha; Hash, Kristina M.

    2017-01-01

    Despite its ubiquity, social work educators are just beginning to harness social media in teaching. In this teaching note, we discuss our use of Twitter in a bachelor's-level macro Human Behavior in the Social Environment course. We present results from a survey of 45 students designed to assess their perceptions of Twitter use in the classroom…

  4. 77 FR 64167 - Self-Regulatory Organizations; The NASDAQ Stock Market LLC; Notice of Filing of Proposed Rule...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-10-18

    ..., offers investors a trade execution tool which should lead to a greater level of transparency as it... for using the INAV, investors should note that the INAV is only an estimation of a fund's value, and... of the trading day. Investors should also note that INAVs are only calculated and disseminated during...

  5. "Guitar Hero"? My Hero!

    ERIC Educational Resources Information Center

    Way, Judith

    2010-01-01

    "Guitar Hero" is a video game where one or more players use a specially made game-style guitar to play along to popular and well-known songs. Players need to match the correct notes and timings of the sings. An on-screen guide shows players which notes to play, when. There are levels of difficulty in the game, as well as the choices to…

  6. Notes on modeling and simulation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Redondo, Antonio

    These notes present a high-level overview of how modeling and simulation are carried out by practitioners. The discussion is of a general nature; no specific techniques are examined but the activities associated with all modeling and simulation approaches are briefly addressed. There is also a discussion of validation and verification and, at the end, a section on why modeling and simulation are useful.

  7. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Johnson, C.; Burnett, M.; Goodman, C.

    A survey of currency flaw severity was carried out using 300 banknotes and 37 judges. Each judge assigned each note to one of five flaw severity categories. These categories correspond to severity grades of 1 to 5 with 1 equivalent to ''always accepted'' and 5 ''never accepted.'' An average flaw severity grade for each note was obtained by taking the mean of the severity grades assigned to that note by the 37 judges. Thus, each note has a single numerical real-number flaw grade between 1 and 5. Mathematical modeling of the currency flaw survey results is continuing with some verymore » promising initial results. Our present model handles common excess ink and missing ink flaw types quite well. We plan to extend the model to ink level, mash, setoff and blanket impression flaw types.« less

  8. Python Leap Second Management and Implementation of Precise Barycentric Correction (barycorrpy)

    NASA Astrophysics Data System (ADS)

    Kanodia, Shubham; Wright, Jason

    2018-01-01

    We announce barycorrpy (BCPy) , a Python implementation to calculate precise barycentric corrections well below the 1 cm/s level, following the algorithm of Wright and Eastman (2014). This level of precision is required in the search for 1 Earth mass planets in the Habitable Zones of Sun-like stars by the Radial Velocity (RV) method, where the maximum semi-amplitude is about 9 cm/s. We have developed BCPy to be used in the pipeline for the next generation Doppler Spectrometers - Habitable-zone Planet Finder (HPF) and NEID. In this work, we also develop an automated leap second management routine to improve upon the one available in Astropy. It checks for and downloads a new leap second file before converting from the UT time scale to TDB.

  9. Tree planters notes. Volume 43, Number 3, Summer 1992. Quarterly report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mangold, R.; Nisley, R.; Karrfalt, R.

    Contents: survival and growth of planted alaska-cedar seedling in southeast southeast alaska; propagation of loblolly, slash, and longleaf pine from needle fascicles; moisture determination on seeds of honeylocust and mimosa; performance of himalayan blue pine in the northeastern united states; advantages of an effective weed control program for populus hybrids; pales weevil: a serious threat to longleaf pine production; costs and cost component trends of trends of hand and machine planting in the southern united states (1952 to 1990); comparison of a drill-type seeder and a vacuum-drum precision seeder in a virginia loblolly pine nursery; missoula technology and development center'smore » nursery and reforestation programs.« less

  10. Experimental verification of distributed piezoelectric actuators for use in precision space structures

    NASA Technical Reports Server (NTRS)

    Crawley, E. F.; De Luis, J.

    1986-01-01

    An analytic model for structures with distributed piezoelectric actuators is experimentally verified for the cases of both surface-bonded and embedded actuators. A technique for the selection of such piezoelectric actuators' location has been developed, and is noted to indicate that segmented actuators are always more effective than continuous ones, since the output of each can be individually controlled. Manufacturing techniques for the bonding or embedding of segmented piezoelectric actuators are also developed which allow independent electrical contact to be made with each actuator. Static tests have been conducted to determine how the elastic properties of the composite are affected by the presence of an embedded actuator, for the case of glass/epoxy laminates.

  11. A note on local BRST cohomology of Yang-Mills type theories with free Abelian factors

    NASA Astrophysics Data System (ADS)

    Barnich, Glenn; Boulanger, Nicolas

    2018-05-01

    We extend previous work on antifield dependent local Becchi-Rouet-Stora-Tyutin (BRST) cohomology for matter coupled gauge theories of Yang-Mills type to the case of gauge groups that involve free Abelian factors. More precisely, we first investigate in a model independent way how the dynamics enters the computation of the cohomology for a general class of Lagrangians in general spacetime dimensions. We then discuss explicit solutions in the case of specific models. Our analysis has implications for the structure of characteristic cohomology and for consistent deformations of the classical models, as well as for divergences/counterterms and for gauge anomalies that may appear during perturbative quantization.

  12. Optical systems engineering - A tutorial

    NASA Technical Reports Server (NTRS)

    Wyman, C. L.

    1979-01-01

    The paper examines the use of the systems engineering approach in the design of optical systems, noting that the use of such an approach which involves an integrated interdisciplinary approach to the development of systems is most appropriate for optics. It is shown that the high precision character of optics leads to complex and subtle effects on optical system performance, resulting from structural, thermal dynamical, control system, and manufacturing and assembly considerations. Attention is given to communication problems that often occur among users and optical engineers due to the unique factors of optical systems. It is concluded that it is essential that the optics community provide leadership to resolve communication problems and fully formalize the field of optical systems engineering.

  13. Bias error reduction using ratios to baseline experiments. Heat transfer case study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chakroun, W.; Taylor, R.P.; Coleman, H.W.

    1993-10-01

    Employing a set of experiments devoted to examining the effect of surface finish (riblets) on convective heat transfer as an example, this technical note seeks to explore the notion that precision uncertainties in experiments can be reduced by repeated trials and averaging. This scheme for bias error reduction can give considerable advantage when parametric effects are investigated experimentally. When the results of an experiment are presented as a ratio with the baseline results, a large reduction in the overall uncertainty can be achieved when all the bias limits in the variables of the experimental result are fully correlated with thosemore » of the baseline case. 4 refs.« less

  14. Tc-99m TRODAT uptake in an osteoid tumor of clivus.

    PubMed

    Taywade, Sameer; Tripathi, Madhavi; Tandon, Vivek; Das, Chandan Jyoti; Damle, Nishikant Avinash; Shamim, Shamim Ahmed; Thukral, Parul; Bal, Chandrasekhar

    2016-01-01

    Tc-99m TRODAT is cocaine analog and binds to the dopamine transporter in vivo . Tc-99m TRODAT single-photon emission computed tomography/computed tomography. (SPECT/CT) is useful for demonstrating presynaptic dopaminergic dysfunction in patients with Parkinsonism. However, few reports have shown extrastriatal uptake of Tc-99m TRODAT. We present the case of a 67-year-old male who underwent Tc-99m TRODAT SPECT/CT for evaluation of Parkinsonism. In addition to tracer binding in the striatum, tracer uptake was noted in an osteoid tumor of the clivus. Integrated SPECT/CT enabled precise localization and characterization of the extrastriatal site of tracer binding and emphasizes the importance of such coincidental findings.

  15. Examination and treatment of a professional ballet dancer with a suspected acetabular labral tear: A case report.

    PubMed

    Khoo-Summers, Lynnette; Bloom, Nancy J

    2015-08-01

    Dancers are at risk for developing groin pain that is due to acetabular labral tears. Although surgical management of labral tears has been reported extensively, conservative management has been poorly described. This case report describes the examination, diagnosis, and treatment of groin pain in a professional ballet dancer with a suspected acetabular labral tear. Treatment focused on decreasing anterior hip joint stresses and improving the precision of hip motion through correction of alignment and movement impairments noted during functional activities and dance. Successful outcomes included a reduction in pain and return to professional ballet dancing. Copyright © 2015 Elsevier Ltd. All rights reserved.

  16. Exploring the impact of music concerts in promoting well-being in dementia care.

    PubMed

    Shibazaki, Kagari; Marshall, Nigel A

    2017-05-01

    This study explores the specific effects of live music concerts on the clients with dementia, their families and nursing staff/caregivers. Researchers attended 22 concerts in care facilities in England and Japan. Interviews were carried out with clients with dementia, nursing staff and family members. Observations were also carried out before, during and after the concerts. All observations were recorded in field notes. The effect of the concerts in both countries was seen to be beneficial to all clients and nursing staff, whether or not they attended the concert. Interviews with clients with mild to mid-stage dementia noted increased levels of cooperation, interaction and conversation. Those with more advanced forms of dementia exhibited decreased levels of agitation and anti-social behaviour. Staff members reported increased levels of care, cooperation and opportunities for assessment. Family members noted an increase in the levels of well-being in their partner/parent as well as in themselves. The study also suggested that the knowledge of musical components, an awareness of the rules of music and specific musical preferences appear to remain well beyond the time when other cognitive skills and abilities have disappeared. This initial study provided some further indication in terms of the uses of music as a non-pharmacological intervention for those living with all stages of dementia. These included opportunities for assessment of physical abilities as well as facilitating an increasing level of care.

  17. Neural decoding of treadmill walking from noninvasive electroencephalographic signals

    PubMed Central

    Presacco, Alessandro; Goodman, Ronald; Forrester, Larry

    2011-01-01

    Chronic recordings from ensembles of cortical neurons in primary motor and somatosensory areas in rhesus macaques provide accurate information about bipedal locomotion (Fitzsimmons NA, Lebedev MA, Peikon ID, Nicolelis MA. Front Integr Neurosci 3: 3, 2009). Here we show that the linear and angular kinematics of the ankle, knee, and hip joints during both normal and precision (attentive) human treadmill walking can be inferred from noninvasive scalp electroencephalography (EEG) with decoding accuracies comparable to those from neural decoders based on multiple single-unit activities (SUAs) recorded in nonhuman primates. Six healthy adults were recorded. Participants were asked to walk on a treadmill at their self-selected comfortable speed while receiving visual feedback of their lower limbs (i.e., precision walking), to repeatedly avoid stepping on a strip drawn on the treadmill belt. Angular and linear kinematics of the left and right hip, knee, and ankle joints and EEG were recorded, and neural decoders were designed and optimized with cross-validation procedures. Of note, the optimal set of electrodes of these decoders were also used to accurately infer gait trajectories in a normal walking task that did not require subjects to control and monitor their foot placement. Our results indicate a high involvement of a fronto-posterior cortical network in the control of both precision and normal walking and suggest that EEG signals can be used to study in real time the cortical dynamics of walking and to develop brain-machine interfaces aimed at restoring human gait function. PMID:21768121

  18. Progress of targeted genome modification approaches in higher plants.

    PubMed

    Cardi, Teodoro; Neal Stewart, C

    2016-07-01

    Transgene integration in plants is based on illegitimate recombination between non-homologous sequences. The low control of integration site and number of (trans/cis)gene copies might have negative consequences on the expression of transferred genes and their insertion within endogenous coding sequences. The first experiments conducted to use precise homologous recombination for gene integration commenced soon after the first demonstration that transgenic plants could be produced. Modern transgene targeting categories used in plant biology are: (a) homologous recombination-dependent gene targeting; (b) recombinase-mediated site-specific gene integration; (c) oligonucleotide-directed mutagenesis; (d) nuclease-mediated site-specific genome modifications. New tools enable precise gene replacement or stacking with exogenous sequences and targeted mutagenesis of endogeneous sequences. The possibility to engineer chimeric designer nucleases, which are able to target virtually any genomic site, and use them for inducing double-strand breaks in host DNA create new opportunities for both applied plant breeding and functional genomics. CRISPR is the most recent technology available for precise genome editing. Its rapid adoption in biological research is based on its inherent simplicity and efficacy. Its utilization, however, depends on available sequence information, especially for genome-wide analysis. We will review the approaches used for genome modification, specifically those for affecting gene integration and modification in higher plants. For each approach, the advantages and limitations will be noted. We also will speculate on how their actual commercial development and implementation in plant breeding will be affected by governmental regulations.

  19. Use of piezosurgery for internal auditory canal drilling in acoustic neuroma surgery.

    PubMed

    Grauvogel, Juergen; Scheiwe, Christian; Kaminsky, Jan

    2011-10-01

    Piezosurgery is based on microvibrations generated by the piezoelectrical effect and has a selective bone-cutting ability with preservation of soft tissue. This study examined the applicability of Piezosurgery compared to rotating drills (RD) for internal auditory canal (IAC) opening in acoustic neuroma (AN) surgery. Piezosurgery was used in eight patients for IAC drilling in AN surgery. After exposition of the IAC and tumor, the posterior wall of the IAC was drilled using Piezosurgery instead of RD. Piezosurgery was evaluated with respect to practicability, safety, preciseness of bone cutting, preservation of cranial nerves, influences on neurophysiological monitoring, and facial nerve and hearing outcome. Piezosurgery was successfully used for selective bone cutting, while cranial nerves were structurally and functionally preserved, which could be measured by means of neuromonitoring. Piezosurgery guaranteed a safe and precise cut by removing bone layer by layer in a shaping way. Compared to RD, limited influence on neurophysiological monitoring attributable to Piezosurgery was noted, allowing for continuous neuromonitoring. No disadvantage due to microvibrations was noticed concerning hearing function. The angled tip showed better handling in right-sided than in left-sided tumors in the hands of a right-handed surgeon. The short, thick handpiece may be improved for more convenient handling. Piezosurgery is a safe tool for selective bone cutting for opening of the IAC with preservation of facial nerve and hearing function in AN surgery. Piezosurgery has the potential to replace RD for this indication because of its safe and precise bone-cutting properties.

  20. Accuracy of active chirp linearization for broadband frequency modulated continuous wave ladar.

    PubMed

    Barber, Zeb W; Babbitt, Wm Randall; Kaylor, Brant; Reibel, Randy R; Roos, Peter A

    2010-01-10

    As the bandwidth and linearity of frequency modulated continuous wave chirp ladar increase, the resulting range resolution, precisions, and accuracy are improved correspondingly. An analysis of a very broadband (several THz) and linear (<1 ppm) chirped ladar system based on active chirp linearization is presented. Residual chirp nonlinearity and material dispersion are analyzed as to their effect on the dynamic range, precision, and accuracy of the system. Measurement precision and accuracy approaching the part per billion level is predicted.

  1. Relationships Between the Performance of Time/Frequency Standards and Navigation/Communication Systems

    NASA Technical Reports Server (NTRS)

    Hellwig, H.; Stein, S. R.; Walls, F. L.; Kahan, A.

    1978-01-01

    The relationship between system performance and clock or oscillator performance is discussed. Tradeoffs discussed include: short term stability versus bandwidth requirements; frequency accuracy versus signal acquisition time; flicker of frequency and drift versus resynchronization time; frequency precision versus communications traffic volume; spectral purity versus bit error rate, and frequency standard stability versus frequency selection and adjustability. The benefits and tradeoffs of using precise frequency and time signals are various levels of precision and accuracy are emphasized.

  2. Childhood Lead Poisoning in the '90s.

    ERIC Educational Resources Information Center

    Piomelli, Sergio

    1994-01-01

    Notes that, despite gains in eliminating lead sources, there are still detectable effects from low-level exposure. Discusses at what level of exposure the adverse effects of lead become trivial and what measures, if any, should be taken to reduce low-level exposure. (HTH)

  3. Economic and phosphorus-related effects of precision feeding and forage management at a farm scale

    USDA-ARS?s Scientific Manuscript database

    A system-level redesign of farm management is needed to maintain economic viability of the farm while addressing phosphorous imbalance problems caused by many current practices. One innovative strategy, precision feed management (PFM), reduces soil-phosphorus build-up by limiting feed and fertilizer...

  4. A Simple, Inexpensive Water-Leveling Device for Ultramicrotomy.

    ERIC Educational Resources Information Center

    Brooks, Austin E.

    1978-01-01

    Describes a device for maintaining the proper water level in knife boats during ultramicrotomy. Water levels in troughs are adjusted rapidly and precisely during the cutting process. Illustrations are included. (Author/MA)

  5. Deep-Dive Targeted Quantification for Ultrasensitive Analysis of Proteins in Nondepleted Human Blood Plasma/Serum and Tissues

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nie, Song; Shi, Tujin; Fillmore, Thomas L.

    Mass spectrometry-based targeted proteomics (e.g., selected reaction monitoring, SRM) is emerging as an attractive alternative to immunoassays for protein quantification. Recently we have made significant progress in SRM sensitivity for enabling quantification of low ng/mL to sub-ng/mL level proteins in nondepleted human blood plasma/serum without affinity enrichment. However, precise quantification of extremely low abundant but biologically important proteins (e.g., ≤100 pg/mL in blood plasma/serum) using targeted proteomics approaches still remains challenging. To address this need, we have developed an antibody-independent Deep-Dive SRM (DD-SRM) approach that capitalizes on multidimensional high-resolution reversed-phase liquid chromatography (LC) separation for target peptide enrichment combined withmore » precise selection of target peptide fractions of interest, significantly improving SRM sensitivity by ~5 orders of magnitude when compared to conventional LC-SRM. Application of DD-SRM to human serum and tissue has been demonstrated to enable precise quantification of endogenous proteins at ~10 pg/mL level in nondepleted serum and at <10 copies per cell level in tissue. Thus, DD-SRM holds great promise for precisely measuring extremely low abundance proteins or protein modifications, especially when high-quality antibody is not available.« less

  6. Desired Precision in Multi-Objective Optimization: Epsilon Archiving or Rounding Objectives?

    NASA Astrophysics Data System (ADS)

    Asadzadeh, M.; Sahraei, S.

    2016-12-01

    Multi-objective optimization (MO) aids in supporting the decision making process in water resources engineering and design problems. One of the main goals of solving a MO problem is to archive a set of solutions that is well-distributed across a wide range of all the design objectives. Modern MO algorithms use the epsilon dominance concept to define a mesh with pre-defined grid-cell size (often called epsilon) in the objective space and archive at most one solution at each grid-cell. Epsilon can be set to the desired precision level of each objective function to make sure that the difference between each pair of archived solutions is meaningful. This epsilon archiving process is computationally expensive in problems that have quick-to-evaluate objective functions. This research explores the applicability of a similar but computationally more efficient approach to respect the desired precision level of all objectives in the solution archiving process. In this alternative approach each objective function is rounded to the desired precision level before comparing any new solution to the set of archived solutions that already have rounded objective function values. This alternative solution archiving approach is compared to the epsilon archiving approach in terms of efficiency and quality of archived solutions for solving mathematical test problems and hydrologic model calibration problems.

  7. Apathy and Reduced Speed of Processing Underlie Decline in Verbal Fluency following DBS

    PubMed Central

    Foltynie, Tom; Zrinzo, Ludvic; Hyam, Jonathan A.; Limousin, Patricia

    2017-01-01

    Objective. Reduced verbal fluency is a strikingly uniform finding following deep brain stimulation (DBS) for Parkinson's disease (PD). The precise cognitive mechanism underlying this reduction remains unclear, but theories have suggested reduced motivation, linguistic skill, and/or executive function. It is of note, however, that previous reports have failed to consider the potential role of any changes in speed of processing. Thus, the aim of this study was to examine verbal fluency changes with a particular focus on the role of cognitive speed. Method. In this study, 28 patients with PD completed measures of verbal fluency, motivation, language, executive functioning, and speed of processing, before and after DBS. Results. As expected, there was a marked decline in verbal fluency but also in a timed test of executive functions and two measures of speed of processing. Verbal fluency decline was associated with markers of linguistic and executive functioning, but not after speed of processing was statistically controlled for. In contrast, greater decline in verbal fluency was associated with higher levels of apathy at baseline, which was not associated with changes in cognitive speed. Discussion. Reduced generativity and processing speed may account for the marked reduction in verbal fluency commonly observed following DBS. PMID:28408788

  8. Preliminary design notes on a low F-number EMR

    NASA Technical Reports Server (NTRS)

    Mihora, D. J.

    1982-01-01

    Conceptual design studies were completed on a new Electrostatic Membrane Reflector, EMR. This new model incorporates both a preformed, curved membrane reflector and membrane control surface. This improved model is the second step toward a high precision large space antenna that could eventually exhibit a performance in terms of aperture diameter to surface quality exceeding 1,000,000. Design trades indicate that the goal of a low ratio of focal length to aperture diameter (f sub n) can be achieved while operating in a humid sea-level environment. A nominal surface quality of 1.0 mm (RMS) is possible using available off-the-shelf commercial membranes. Both the membrane reflector and control electrode surface are fabricated from 12 gore segments and attached to the available 12 sided, 4.88 m diameter rim. The preferred conceptual design has a f sub n = 1.0. The 4.88 m aperture is performed with a centerline displacement of 0.306 m. The nominal spacing between the membrane reflector and the electrode control surface is 50.8 mm. The centerline membrane displacement from its performed to its tensioned, smooth shape is about 3 mm. The membrane tensioning is achieved by application of an electrostatic pressure of 2.6 N/sq cm and a voltage of about 38 kV.

  9. Digital assist: A comparison of two note-taking methods (traditional vs. digital pen) for students with emotional behavioral disorders

    NASA Astrophysics Data System (ADS)

    Rody, Carlotta A.

    High school biology classes traditionally follow a lecture format to disseminate content and new terminology. With the inclusive practices of No Child Left Behind, the Common Core State Standards, and end-of-course exam requirement for high school diplomas, classes include a large range of achievement levels and abilities. Teachers assume, often incorrectly, that students come to class prepared to listen and take notes. In a standard diploma, high school biology class in a separate school for students with emotional and behavioral disorders, five students participated in a single-subject, alternating treatment design study that compared the use of regular pens and digital pens to take notes during 21 lecture sessions. Behavior measures were threefold between the two interventions: (a) quantity of notes taken per minute during lectures, (b) quantity of notes or notations taken during review pauses, and (c) percent of correct responses on the daily comprehension quizzes. The study's data indicated that two students were inclined to take more lecture notes when using the digital pen. Two students took more notes with the regular pen. One student demonstrated no difference in her performance with either pen type. Both female students took more notes per minute, on average, than the three males regardless of pen type. During the review pause, three of the five students only added notes or notations to their notes when using the regular pen. The remaining two students did not add to their notes. Quiz scores differed in favor of the regular pen. All five participants earned higher scores on quizzes given during regular pen sessions. However, the differences were minor, and recommendations are made for specific training in note-taking, the pause strategy, and digital pen fluency which may produce different results for both note-taking and quiz scores.

  10. Quantifying condition-dependent intracellular protein levels enables high-precision fitness estimates.

    PubMed

    Geiler-Samerotte, Kerry A; Hashimoto, Tatsunori; Dion, Michael F; Budnik, Bogdan A; Airoldi, Edoardo M; Drummond, D Allan

    2013-01-01

    Countless studies monitor the growth rate of microbial populations as a measure of fitness. However, an enormous gap separates growth-rate differences measurable in the laboratory from those that natural selection can distinguish efficiently. Taking advantage of the recent discovery that transcript and protein levels in budding yeast closely track growth rate, we explore the possibility that growth rate can be more sensitively inferred by monitoring the proteomic response to growth, rather than growth itself. We find a set of proteins whose levels, in aggregate, enable prediction of growth rate to a higher precision than direct measurements. However, we find little overlap between these proteins and those that closely track growth rate in other studies. These results suggest that, in yeast, the pathways that set the pace of cell division can differ depending on the growth-altering stimulus. Still, with proper validation, protein measurements can provide high-precision growth estimates that allow extension of phenotypic growth-based assays closer to the limits of evolutionary selection.

  11. Using Aoristic Analysis to Link Remote and Ground-Level Phenological Observations

    NASA Astrophysics Data System (ADS)

    Henebry, G. M.

    2013-12-01

    Phenology is about observing events in time and space. With the advent of publically accessible geospatial datastreams and easy to use mapping software, specifying where an event occurs is much less of a challenge than it was just two decades ago. In contrast, specifying when an event occurs remains a nontrivial function of a population of organismal responses, sampling interval, compositing period, and reporting precision. I explore how aoristic analysis can be used to analyzing spatiotemporal events for which the location is known to acceptable levels of precision but for which temporal coordinates are poorly specified or only partially bounded. Aoristic analysis was developed in the late 1990s in the field of quantitative criminology to leverage temporally imprecise geospatial data of crime reports. Here I demonstrate how aoristic analysis can be used to link remotely sensed observations of land surface phenology to ground-level observations of organismal phenophase transitions. Explicit representation of the windows of temporal uncertainty with aoristic weights enables cross-validation exercises and forecasting efforts to avoid false precision.

  12. Musical structure analysis using similarity matrix and dynamic programming

    NASA Astrophysics Data System (ADS)

    Shiu, Yu; Jeong, Hong; Kuo, C.-C. Jay

    2005-10-01

    Automatic music segmentation and structure analysis from audio waveforms based on a three-level hierarchy is examined in this research, where the three-level hierarchy includes notes, measures and parts. The pitch class profile (PCP) feature is first extracted at the note level. Then, a similarity matrix is constructed at the measure level, where a dynamic time warping (DTW) technique is used to enhance the similarity computation by taking the temporal distortion of similar audio segments into account. By processing the similarity matrix, we can obtain a coarse-grain music segmentation result. Finally, dynamic programming is applied to the coarse-grain segments so that a song can be decomposed into several major parts such as intro, verse, chorus, bridge and outro. The performance of the proposed music structure analysis system is demonstrated for pop and rock music.

  13. A cross-sectional assessment of biomarker levels around implants versus natural teeth in periodontal maintenance patients.

    PubMed

    Recker, Erica N; Avila-Ortiz, Gustavo; Fischer, Carol L; Pagan-Rivera, Keyla; Brogden, Kim A; Dawson, Deborah V; Elangovan, Satheesh

    2015-02-01

    Recent studies point to the clinical utility of using peri-implant sulcular fluid (PISF) as a valuable diagnostic aid for monitoring peri-implant tissue health. The objectives of this study are to determine the levels of key biomarkers in PISF in periodontal maintenance participants and compare them with their corresponding levels in gingival crevicular fluid (GCF) obtained from the same participants. PISF and GCF were collected from an implant and a contralateral natural tooth after the clinical examination of 73 participants. The levels of interleukin (IL)-1α, IL-1β, IL-6, IL-8, IL-10, IL-12, IL-17A, tumor necrosis factor (TNF)-α, C-reactive protein, osteoprotegerin, leptin, and adiponectin were determined using multiplex proteomic immunoassays. The correlation of biomarker concentrations between GCF versus PISF, within GCF or PISF, and with several covariates (age, brushing frequency, days since professional cleaning, probing depth [PD], and plaque index) were also determined. Significantly higher levels of IL-17A (P = 0.02) and TNF-α (P = 0.03) were noted in PISF when compared with their levels in GCF. Significant positive correlations were noted between the concentrations of cytokines in PISF versus their levels in GCF. Among the covariates, a significant positive correlation was noted between mean PDs around implants and levels of IL-1β (P <0.05) and IL-8 (P <0.05) in PISF. The results of this study point to the differential expression of specific biomarkers in GCF versus their levels in PISF in periodontal maintenance patients, which is critical information before establishing PISF as a diagnostic fluid to monitor peri-implant health.

  14. An randomized controlled trial of Post-it® notes did not increase postal response rates in older depressed participants.

    PubMed

    Lewis, Helen; Keding, Ada; Bosanquet, Katharine; Gilbody, Simon; Torgerson, David

    2017-02-01

    Our aim was to evaluate the effectiveness of a Post-it® note to increase response rates and shorten response times to a 4-month postal follow-up questionnaire sent to participants taking part in the Collaborative Care in Screen-Positive Elders (CASPER) trials. Our trial was a two-arm randomized controlled trial comparing response rates to questionnaires with a printed Post-it® note (intervention) and without (control), nested in multi centred randomized controlled trials of older people with varying levels of depressive symptoms; the CASPER + and CASPER Self Help for those At Risk of Depression (SHARD) trials. A total of 611 participants were eligible and randomized. The primary outcome was response rates, secondary outcomes were time to response and need for a reminder. Of 297 participants, 266 (89.6%) returned their 4-month questionnaire in the post-it note arm, compared with 282 of 314 participants (89.8%) in the control arm (OR = 0.97, 95% CI: 0.57, 1.65, P = 0.913). There were no statistically significant differences in time to respond or the need to be sent a reminder. Patients with a major depressive episode were more likely to return questionnaires with post-it notes (P of interaction = .019). There was no significant difference in response rates, time to response, or the need for a reminder between the intervention and control at 4-month follow up for older people with depressive symptoms. However, there was a significant interaction between the Post-it® note group and level of depression. © 2016 John Wiley & Sons, Ltd.

  15. Screening Currency Notes for Microbial Pathogens and Antibiotic Resistance Genes Using a Shotgun Metagenomic Approach

    PubMed Central

    Jalali, Saakshi; Kohli, Samantha; Latka, Chitra; Bhatia, Sugandha; Vellarikal, Shamsudheen Karuthedath; Sivasubbu, Sridhar; Scaria, Vinod; Ramachandran, Srinivasan

    2015-01-01

    Fomites are a well-known source of microbial infections and previous studies have provided insights into the sojourning microbiome of fomites from various sources. Paper currency notes are one of the most commonly exchanged objects and its potential to transmit pathogenic organisms has been well recognized. Approaches to identify the microbiome associated with paper currency notes have been largely limited to culture dependent approaches. Subsequent studies portrayed the use of 16S ribosomal RNA based approaches which provided insights into the taxonomical distribution of the microbiome. However, recent techniques including shotgun sequencing provides resolution at gene level and enable estimation of their copy numbers in the metagenome. We investigated the microbiome of Indian paper currency notes using a shotgun metagenome sequencing approach. Metagenomic DNA isolated from samples of frequently circulated denominations of Indian currency notes were sequenced using Illumina Hiseq sequencer. Analysis of the data revealed presence of species belonging to both eukaryotic and prokaryotic genera. The taxonomic distribution at kingdom level revealed contigs mapping to eukaryota (70%), bacteria (9%), viruses and archae (~1%). We identified 78 pathogens including Staphylococcus aureus, Corynebacterium glutamicum, Enterococcus faecalis, and 75 cellulose degrading organisms including Acidothermus cellulolyticus, Cellulomonas flavigena and Ruminococcus albus. Additionally, 78 antibiotic resistance genes were identified and 18 of these were found in all the samples. Furthermore, six out of 78 pathogens harbored at least one of the 18 common antibiotic resistance genes. To the best of our knowledge, this is the first report of shotgun metagenome sequence dataset of paper currency notes, which can be useful for future applications including as bio-surveillance of exchangeable fomites for infectious agents. PMID:26035208

  16. Unsupervised ensemble ranking of terms in electronic health record notes based on their importance to patients.

    PubMed

    Chen, Jinying; Yu, Hong

    2017-04-01

    Allowing patients to access their own electronic health record (EHR) notes through online patient portals has the potential to improve patient-centered care. However, EHR notes contain abundant medical jargon that can be difficult for patients to comprehend. One way to help patients is to reduce information overload and help them focus on medical terms that matter most to them. Targeted education can then be developed to improve patient EHR comprehension and the quality of care. The aim of this work was to develop FIT (Finding Important Terms for patients), an unsupervised natural language processing (NLP) system that ranks medical terms in EHR notes based on their importance to patients. We built FIT on a new unsupervised ensemble ranking model derived from the biased random walk algorithm to combine heterogeneous information resources for ranking candidate terms from each EHR note. Specifically, FIT integrates four single views (rankers) for term importance: patient use of medical concepts, document-level term salience, word co-occurrence based term relatedness, and topic coherence. It also incorporates partial information of term importance as conveyed by terms' unfamiliarity levels and semantic types. We evaluated FIT on 90 expert-annotated EHR notes and used the four single-view rankers as baselines. In addition, we implemented three benchmark unsupervised ensemble ranking methods as strong baselines. FIT achieved 0.885 AUC-ROC for ranking candidate terms from EHR notes to identify important terms. When including term identification, the performance of FIT for identifying important terms from EHR notes was 0.813 AUC-ROC. Both performance scores significantly exceeded the corresponding scores from the four single rankers (P<0.001). FIT also outperformed the three ensemble rankers for most metrics. Its performance is relatively insensitive to its parameter. FIT can automatically identify EHR terms important to patients. It may help develop future interventions to improve quality of care. By using unsupervised learning as well as a robust and flexible framework for information fusion, FIT can be readily applied to other domains and applications. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. Neighborhood Sociodemographic Predictors of Serious Emotional Disturbance (SED) in Schools: Demonstrating a Small Area Estimation Method in the National Comorbidity Survey (NCS-A) Adolescent Supplement

    PubMed Central

    Alegría, Margarita; Kessler, Ronald C.; McLaughlin, Katie A.; Gruber, Michael J.; Sampson, Nancy A.; Zaslavsky, Alan M.

    2014-01-01

    We evaluate the precision of a model estimating school prevalence of SED using a small area estimation method based on readily-available predictors from area-level census block data and school principal questionnaires. Adolescents at 314 schools participated in the National Comorbidity Supplement, a national survey of DSM-IV disorders among adolescents. A multilevel model indicated that predictors accounted for under half of the variance in school-level SED and even less when considering block-group predictors or principal report alone. While Census measures and principal questionnaires are significant predictors of individual-level SED, associations are too weak to generate precise school-level predictions of SED prevalence. PMID:24740174

  18. Evidence for the timing and duration of the last interglacial period from high-precision uranium-series ages of corals on tectonically stable coastlines

    USGS Publications Warehouse

    Muhs, D.R.

    2002-01-01

    The last interglacial period has a timing and duration that can be estimated from U-series dating of emergent, coral-bearing deposits on tectonically stable coastlines. High-precision dating from Bermuda, the Bahamas, Hawaii, and Australia suggests that the last interglacial period had a sea level at least as high as present from ???128,000 to 116,000 yr B.P. Sea level reached a near-present level more quickly after the close of the penultimate glacial period than at the close of the last glacial period and the duration of high sea level is longer than that implied by the deep-sea record. ?? 2002 University of Washington.

  19. Targeting circuits

    PubMed Central

    Rajasethupathy, Priyamvada; Ferenczi, Emily; Deisseroth, Karl

    2017-01-01

    Current optogenetic methodology enables precise inhibition or excitation of neural circuits, spanning timescales as needed from the acute (milliseconds) to the chronic (many days or more), for experimental modulation of network activity and animal behavior. Such broad temporal versatility, unique to optogenetic control, is particularly powerful when combined with brain activity measurements that span both acute and chronic timescales as well. This enables, for instance, the study of adaptive circuit dynamics across the intact brain, and tuning interventions to match activity patterns naturally observed during behavior in the same individual. Although the impact of this approach has been greater on basic research than on clinical translation, it is natural to ask if specific neural circuit activity patterns discovered to be involved in controlling adaptive or maladaptive behaviors could become targets for treatment of neuropsychiatric diseases. Here we consider the landscape of such ideas related to therapeutic targeting of circuit dynamics, taking note of developments not only in optical but also in ultrasonic, magnetic, and thermal methods. We note the recent emergence of first-in-kind optogenetically-guided clinical outcomes, as well as opportunities related to the integration of interventions and readouts spanning diverse circuit-physiology, molecular, and behavioral modalities. PMID:27104976

  20. A cautionary note on the use of some mass flow controllers

    NASA Astrophysics Data System (ADS)

    Weinheimer, Andrew J.; Ridley, Brian A.

    1990-06-01

    Commercial mass flow controllers are widely used in atmospheric research where precise and constant gas flows are required. We have determined, however, that some commonly used controllers are far more sensitive to ambient pressure than is acknowledged in the literature of the manufacturers. Since a flow error can lead directly to a measurement error of the same magnitude, this is a matter of great concern. Indeed, in our particular application, were we not aware of this problem, our measurements would be subject to a systematic error that increased with altitude (i.e., a drift), up to a factor of 2 at the highest altitudes (˜37 km). In this note we present laboratory measurements of the errors of two brands of flow controllers when operated at pressures down to a few millibars. The errors are as large as a factor of 2 to 3 and depend not simply on the ambient pressure at a given time, but also on the pressure history. In addition there is a large dependence on flow setting. In light of these flow errors, some past measurements of chemical species in the stratosphere will need to be revised.

  1. Vision-based Detection of Acoustic Timed Events: a Case Study on Clarinet Note Onsets

    NASA Astrophysics Data System (ADS)

    Bazzica, A.; van Gemert, J. C.; Liem, C. C. S.; Hanjalic, A.

    2017-05-01

    Acoustic events often have a visual counterpart. Knowledge of visual information can aid the understanding of complex auditory scenes, even when only a stereo mixdown is available in the audio domain, \\eg identifying which musicians are playing in large musical ensembles. In this paper, we consider a vision-based approach to note onset detection. As a case study we focus on challenging, real-world clarinetist videos and carry out preliminary experiments on a 3D convolutional neural network based on multiple streams and purposely avoiding temporal pooling. We release an audiovisual dataset with 4.5 hours of clarinetist videos together with cleaned annotations which include about 36,000 onsets and the coordinates for a number of salient points and regions of interest. By performing several training trials on our dataset, we learned that the problem is challenging. We found that the CNN model is highly sensitive to the optimization algorithm and hyper-parameters, and that treating the problem as binary classification may prevent the joint optimization of precision and recall. To encourage further research, we publicly share our dataset, annotations and all models and detail which issues we came across during our preliminary experiments.

  2. Calibration of water distribution network of the Ramnagar zone in Nagpur City using online pressure and flow data

    NASA Astrophysics Data System (ADS)

    Jadhao, Ramrao D.; Gupta, Rajesh

    2018-03-01

    Calibration of hydraulic model of a water distribution network is required to match the model results of flows and pressures with those obtained in the field. This is a challenging task considering the involvement of a large number of parameters. Having more precise data helps in reducing time and results in better calibration as shown herein with a case study of one hydraulic zone served from the Ramnagar Ground Service Reservoir in Nagpur City. Flow and pressure values for the entire day were obtained through data loggers. Network details regarding pipe lengths, diameters, installation year and material were obtained with the largest possible accuracy. Locations of consumers on the network were noted and average nodal consumptions were obtained from the billing records. The non-revenue water losses were uniformly allocated to all junctions. Valve positions and their operating status were noted from the field and used. The pipe roughness coefficients were adjusted to match the model values with field values of pressures at observation nodes by minimizing the sum of square of difference between them. This paper aims at describing the entire process from collection of the required data to the calibration of the network.

  3. On-chip dual-comb source for spectroscopy

    PubMed Central

    Dutt, Avik; Joshi, Chaitanya; Ji, Xingchen; Cardenas, Jaime; Okawachi, Yoshitomo; Luke, Kevin; Gaeta, Alexander L.; Lipson, Michal

    2018-01-01

    Dual-comb spectroscopy is a powerful technique for real-time, broadband optical sampling of molecular spectra, which requires no moving components. Recent developments with microresonator-based platforms have enabled frequency combs at the chip scale. However, the need to precisely match the resonance wavelengths of distinct high quality-factor microcavities has hindered the development of on-chip dual combs. We report the simultaneous generation of two microresonator combs on the same chip from a single laser, drastically reducing experimental complexity. We demonstrate broadband optical spectra spanning 51 THz and low-noise operation of both combs by deterministically tuning into soliton mode-locked states using integrated microheaters, resulting in narrow (<10 kHz) microwave beat notes. We further use one comb as a reference to probe the formation dynamics of the other comb, thus introducing a technique to investigate comb evolution without auxiliary lasers or microwave oscillators. We demonstrate high signal-to-noise ratio absorption spectroscopy spanning 170 nm using the dual-comb source over a 20-μs acquisition time. Our device paves the way for compact and robust spectrometers at nanosecond time scales enabled by large beat-note spacings (>1 GHz). PMID:29511733

  4. Estimated association between dwelling soil contamination and internal radiation contamination levels after the 2011 Fukushima Daiichi nuclear accident in Japan.

    PubMed

    Tsubokura, Masaharu; Nomura, Shuhei; Sakaihara, Kikugoro; Kato, Shigeaki; Leppold, Claire; Furutani, Tomoyuki; Morita, Tomohiro; Oikawa, Tomoyoshi; Kanazawa, Yukio

    2016-06-29

    Measurement of soil contamination levels has been considered a feasible method for dose estimation of internal radiation exposure following the Chernobyl disaster by means of aggregate transfer factors; however, it is still unclear whether the estimation of internal contamination based on soil contamination levels is universally valid or incident specific. To address this issue, we evaluated relationships between in vivo and soil cesium-137 (Cs-137) contamination using data on internal contamination levels among Minamisoma (10-40 km north from the Fukushima Daiichi nuclear power plant), Fukushima residents 2-3 years following the disaster, and constructed three models for statistical analysis based on continuous and categorical (equal intervals and quantiles) soil contamination levels. A total of 7987 people with a mean age of 55.4 years underwent screening of in vivo Cs-137 whole-body counting. A statistically significant association was noted between internal and continuous Cs-137 soil contamination levels (model 1, p value <0.001), although the association was slight (relative risk (RR): 1.03 per 10 kBq/m(2) increase in soil contamination). Analysis of categorical soil contamination levels showed statistical (but not clinical) significance only in relatively higher soil contamination levels (model 2: Cs-137 levels above 100 kBq/m(2) compared to those <25 kBq/m(2), RR=1.75, p value <0.01; model 3: levels above 63 kBq/m(2) compared to those <11 kBq/m(2), RR=1.45, p value <0.05). Low levels of internal and soil contamination were not associated, and only loose/small associations were observed in areas with slightly higher levels of soil contamination in Fukushima, representing a clear difference from the strong associations found in post-disaster Chernobyl. These results indicate that soil contamination levels generally do not contribute to the internal contamination of residents in Fukushima; thus, individual measurements are essential for the precise evaluation of chronic internal radiation contamination. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  5. Progress Towards a High-Precision Infrared Spectroscopic Survey of the H_3^+ Ion

    NASA Astrophysics Data System (ADS)

    Perry, Adam J.; Hodges, James N.; Markus, Charles R.; Kocheril, G. Stephen; Jenkins, Paul A., II; McCall, Benjamin J.

    2015-06-01

    The trihydrogen cation, H_3^+, represents one of the most important and fundamental molecular systems. Having only two electrons and three nuclei, H_3^+ is the simplest polyatomic system and is a key testing ground for the development of new techniques for calculating potential energy surfaces and predicting molecular spectra. Corrections that go beyond the Born-Oppenheimer approximation, including adiabatic, non-adiabatic, relativistic, and quantum electrodynamic corrections are becoming more feasible to calculate. As a result, experimental measurements performed on the H_3^+ ion serve as important benchmarks which are used to test the predictive power of new computational methods. By measuring many infrared transitions with precision at the sub-MHz level it is possible to construct a list of the most highly precise experimental rovibrational energy levels for this molecule. Until recently, only a select handful of infrared transitions of this molecule have been measured with high precision (˜ 1 MHz). Using the technique of Noise Immune Cavity Enhanced Optical Heterodyne Velocity Modulation Spectroscopy, we are aiming to produce the largest high-precision spectroscopic dataset for this molecule to date. Presented here are the current results from our survey along with a discussion of the combination differences analysis used to extract the experimentally determined rovibrational energy levels. O. Polyansky, et al., Phil. Trans. R. Soc. A (2012), 370, 5014. M. Pavanello, et al., J. Chem. Phys. (2012), 136, 184303. L. Diniz, et al., Phys. Rev. A (2013), 88, 032506. L. Lodi, et al., Phys. Rev. A (2014), 89, 032505. J. Hodges, et al., J. Chem. Phys (2013), 139, 164201.

  6. Comparative effects of parathion and chlorpyrifos on extracellular endocannabinoid levels in rat hippocampus: Influence on cholinergic toxicity

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, Jing; Parsons, Loren; Pope, Carey, E-mail: carey.pope@okstate.edu

    2013-11-01

    Parathion (PS) and chlorpyrifos (CPF) are organophosphorus insecticides (OPs) that elicit acute toxicity by inhibiting acetylcholinesterase (AChE). Endocannabinoids (eCBs, N-arachidonoylethanolamine, AEA; 2-arachidonoylglycerol, 2AG) can modulate neurotransmission by inhibiting neurotransmitter release. We proposed that differential inhibition of eCB-degrading enzymes (fatty acid amide hydrolase, FAAH, and monoacylglycerol lipase, MAGL) by PS and CPF leads to differences in extracellular eCB levels and toxicity. Microdialysis cannulae were implanted into hippocampus of adult male rats followed by treatment with vehicle (peanut oil, 2 ml/kg, sc), PS (27 mg/kg) or CPF (280 mg/kg) 6–7 days later. Signs of toxicity, AChE, FAAH and MAGL inhibition, and extracellularmore » levels of AEA and 2AG were measured 2 and 4 days later. Signs were noted in PS-treated rats but not in controls or CPF-treated rats. Cholinesterase inhibition was extensive in hippocampus with PS (89–90%) and CPF (78–83%) exposure. FAAH activity was also markedly reduced (88–91%) by both OPs at both time-points. MAGL was inhibited by both OPs but to a lesser degree (35–50%). Increases in extracellular AEA levels were noted after either PS (about 2-fold) or CPF (about 3-fold) while lesser treatment-related 2-AG changes were noted. The cannabinoid CB1 receptor antagonist/inverse agonist AM251 (3 mg/kg, ip) had no influence on functional signs after CPF but markedly decreased toxicity in PS-treated rats. The results suggest that extracellular eCBs levels can be markedly elevated by both PS and CPF. CB1-mediated signaling appears to play a role in the acute toxicity of PS but the role of eCBs in CPF toxicity remains unclear. - Highlights: • Chlorpyrifos and parathion both extensively inhibited hippocampal cholinesterase. • Functional signs were only noted with parathion. • Chlorpyrifos and parathion increased hippocampal extracellular anandamide levels. • 2-Arachidonoylglycerol levels were lesser affected. • The CB1 antagonist AM251 had no effect on chlorpyrifos but reduced parathion toxicity.« less

  7. High Speed Aerodynamic Characteristics of the GAF0PH Aerofoil

    DTIC Science & Technology

    1980-09-01

    upper surface of the aerofoil for angles of incidence greater than 210. POSTAL ADDRESS: Chief Superintendent, Aeronautical Research Laboratories, Box...kCLAERO-.NOTE3 98 -AR-002-223 -LEVEL m DEPARTMENT OF DEFENCE 00 DEFENCE SCIENCE AND TECHNOLOGY ORGANISATION AERONAUTICAL RESEARCH LABORATORIES...MELBOURNE, VICTORIA AERODYNAMICS NOTE 398 ’,\\ HIGH SPEED AERODYNAMIC CHARACTERISTICS OF THE GAFPH AEROFOIL by ~B D :, . , .IR-© Approved for Public Release

  8. ESL VI Curriculum Guide.

    ERIC Educational Resources Information Center

    Flander, Leonard

    This curriculum guide for English as a Second Language (ESL) Level VI is the sixth of six in a Guam Community College ESL project series. The other five guides, a companion teacher's guide and pre- and post-tests are available separately (see note). The entire project centers around the Peabody Kits P, Level P, Level 1, Level 2, Level 3, and the…

  9. ESL V Curriculum Guide.

    ERIC Educational Resources Information Center

    Flander, Leonard

    This curriculum guide for English as a Second Language (ESL) Level V is the fifth of six in the Guam Community College ESL project series. The other five guides, a companion teacher's guide, and pre- and post-tests are available separately (see note). The entire project centers around the Peabody Kits P, Level P, Level 1, Level 2, Level 3, and the…

  10. NOAA - National Oceanic and Atmospheric Administration - Antarctic Ozone

    Science.gov Websites

    Hole Returns to Near Average Levels NOAA HOME WEATHER OCEANS FISHERIES CHARTING SATELLITES Returns to Near Average Levels Improvement Noted After Last Year's Record Breaker November 1, 2007 The

  11. Managing Motivational Needs of the Gifted and Talented.

    ERIC Educational Resources Information Center

    Schilling, Deanna E.

    1986-01-01

    A. Maslow's theory of motivation is described, five levels of needs are identified (physiological, safety, love, esteem, and self-actualization), and implications of each level for parents and teachers of gifted students are noted. (CL)

  12. Fundamental differences between optimization code test problems in engineering applications

    NASA Technical Reports Server (NTRS)

    Eason, E. D.

    1984-01-01

    The purpose here is to suggest that there is at least one fundamental difference between the problems used for testing optimization codes and the problems that engineers often need to solve; in particular, the level of precision that can be practically achieved in the numerical evaluation of the objective function, derivatives, and constraints. This difference affects the performance of optimization codes, as illustrated by two examples. Two classes of optimization problem were defined. Class One functions and constraints can be evaluated to a high precision that depends primarily on the word length of the computer. Class Two functions and/or constraints can only be evaluated to a moderate or a low level of precision for economic or modeling reasons, regardless of the computer word length. Optimization codes have not been adequately tested on Class Two problems. There are very few Class Two test problems in the literature, while there are literally hundreds of Class One test problems. The relative performance of two codes may be markedly different for Class One and Class Two problems. Less sophisticated direct search type codes may be less likely to be confused or to waste many function evaluations on Class Two problems. The analysis accuracy and minimization performance are related in a complex way that probably varies from code to code. On a problem where the analysis precision was varied over a range, the simple Hooke and Jeeves code was more efficient at low precision while the Powell code was more efficient at high precision.

  13. Three-dimensional surgical modelling with an open-source software protocol: study of precision and reproducibility in mandibular reconstruction with the fibula free flap.

    PubMed

    Ganry, L; Quilichini, J; Bandini, C M; Leyder, P; Hersant, B; Meningaud, J P

    2017-08-01

    Very few surgical teams currently use totally independent and free solutions to perform three-dimensional (3D) surgical modelling for osseous free flaps in reconstructive surgery. This study assessed the precision and technical reproducibility of a 3D surgical modelling protocol using free open-source software in mandibular reconstruction with fibula free flaps and surgical guides. Precision was assessed through comparisons of the 3D surgical guide to the sterilized 3D-printed guide, determining accuracy to the millimetre level. Reproducibility was assessed in three surgical cases by volumetric comparison to the millimetre level. For the 3D surgical modelling, a difference of less than 0.1mm was observed. Almost no deformations (<0.2mm) were observed post-autoclave sterilization of the 3D-printed surgical guides. In the three surgical cases, the average precision of fibula free flap modelling was between 0.1mm and 0.4mm, and the average precision of the complete reconstructed mandible was less than 1mm. The open-source software protocol demonstrated high accuracy without complications. However, the precision of the surgical case depends on the surgeon's 3D surgical modelling. Therefore, surgeons need training on the use of this protocol before applying it to surgical cases; this constitutes a limitation. Further studies should address the transfer of expertise. Copyright © 2017 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  14. New paradigm for patient-reported outcomes assessment in foot & ankle research: computerized adaptive testing.

    PubMed

    Hung, Man; Nickisch, Florian; Beals, Timothy C; Greene, Tom; Clegg, Daniel O; Saltzman, Charles L

    2012-08-01

    Accurately measuring, reporting and comparing outcomes is essential for improving health care delivery. Current challenges with available health status scales include patient fatigue, floor/ceiling effects and validity/reliability. This study compared Patient Reported Outcomes Measurement Information System (PROMIS)-based Lower Extremity Physical Function Computerized Adaptive Test (LE CAT) and two legacy scales -the Foot and Function Index (FFI) and the sport module from the Foot and Ankle Ability Measure (spFAAM) -for 287 patients scheduled for elective foot and ankle surgery. We documented the time required by patients to complete the instrument, instrument precision, and the extent to which each instrument covered the full range of physical functioning across the patient sample. Average time of test administration: 66 seconds for LE CAT, 130 seconds for spFAAM and 239 seconds for FFI. All three instruments were fairly precise at intermediate physical functioning levels (i.e., Standard Error of Measurement < 0.35), were relatively less precise at the higher trait levels and the LE CAT maintained precision in the lower range while the spFAAM and FFI's had decreased precision. The LE CAT had less floor/ceiling effects than the FFI and the spFAAM. The LE CAT showed considerable advantage compared to legacy scales for measuring patient-reported outcomes in orthopaedic patients with foot and ankle problems. A paradigm shift to broader use of PROMIS-based CATs should be considered to improve precision and reduce patient burden with patient-reported outcome measuremen foot and ankle patients.

  15. Precision and fast wavelength tuning of a dynamically phase-locked widely-tunable laser.

    PubMed

    Numata, Kenji; Chen, Jeffrey R; Wu, Stewart T

    2012-06-18

    We report a precision and fast wavelength tuning technique demonstrated for a digital-supermode distributed Bragg reflector laser. The laser was dynamically offset-locked to a frequency-stabilized master laser using an optical phase-locked loop, enabling precision fast tuning to and from any frequencies within a ~40-GHz tuning range. The offset frequency noise was suppressed to the statically offset-locked level in less than ~40 μs upon each frequency switch, allowing the laser to retain the absolute frequency stability of the master laser. This technique satisfies stringent requirements for gas sensing lidars and enables other applications that require such well-controlled precision fast tuning.

  16. High-Precision Half-Life Measurements for the Superallowed Fermi β+ Emitters 14O and 18Ne

    NASA Astrophysics Data System (ADS)

    Laffoley, A. T.; Andreoiu, C.; Austin, R. A. E.; Ball, G. C.; Bender, P. C.; Bidaman, H.; Bildstein, V.; Blank, B.; Bouzomita, H.; Cross, D. S.; Deng, G.; Diaz Varela, A.; Dunlop, M. R.; Dunlop, R.; Finlay, P.; Garnsworthy, A. B.; Garrett, P.; Giovinazzo, J.; Grinyer, G. F.; Grinyer, J.; Hadinia, B.; Jamieson, D. S.; Jigmeddorj, B.; Ketelhut, S.; Kisliuk, D.; Leach, K. G.; Leslie, J. R.; MacLean, A.; Miller, D.; Mills, B.; Moukaddam, M.; Radich, A. J.; Rajabali, M. M.; Rand, E. T.; Svensson, C. E.; Tardiff, E.; Thomas, J. C.; Turko, J.; Voss, P.; Unsworth, C.

    High-precision half-life measurements, at the level of ±0.04%, for the superallowed Fermi emitters 14O and 18Ne have been performed at TRIUMF's Isotope Separator and Accelerator facility. Using 3 independent detector systems, a gas-proportional counter, a fast plastic scintillator, and a high-purity germanium array, a series of direct β and γ counting measurements were performed for each of the isotopes. In the case of 14O, these measurements were made to help resolve an existing discrepancy between detection methods, whereas for 18Ne the half-life precision has been improved in anticipation of forthcoming high-precision branching ratio measurements.

  17. Quantum metrology of phase for accelerated two-level atom coupled with electromagnetic field with and without boundary

    NASA Astrophysics Data System (ADS)

    Yang, Ying; Liu, Xiaobao; Wang, Jieci; Jing, Jiliang

    2018-03-01

    We study how to improve the precision of the quantum estimation of phase for an uniformly accelerated atom in fluctuating electromagnetic field by reflecting boundaries. We find that the precision decreases with increases of the acceleration without the boundary. With the presence of a reflecting boundary, the precision depends on the atomic polarization, position and acceleration, which can be effectively enhanced compared to the case without boundary if we choose the appropriate conditions. In particular, with the presence of two parallel reflecting boundaries, we obtain the optimal precision for atomic parallel polarization and the special distance between two boundaries, as if the atom were shielded from the fluctuation.

  18. Precision thermometry and the quantum speed limit

    NASA Astrophysics Data System (ADS)

    Campbell, Steve; Genoni, Marco G.; Deffner, Sebastian

    2018-04-01

    We assess precision thermometry for an arbitrary single quantum system. For a d-dimensional harmonic system we show that the gap sets a single temperature that can be optimally estimated. Furthermore, we establish a simple linear relationship between the gap and this temperature, and show that the precision exhibits a quadratic relationship. We extend our analysis to explore systems with arbitrary spectra, showing that exploiting anharmonicity and degeneracy can greatly enhance the precision of thermometry. Finally, we critically assess the dynamical features of two thermometry protocols for a two level system. By calculating the quantum speed limit we find that, despite the gap fixing a preferred temperature to probe, there is no evidence of this emerging in the dynamical features.

  19. Precision Laser Spectroscopic Measurement of Helium -4(1S2S S(3) to 1S2P P(3)) Lamb Shift and Fine Structure

    NASA Astrophysics Data System (ADS)

    Dixson, Ronald Gene

    This thesis is a presentation of the results of a precise measurement of the absolute wavelength and fine structure splitting of the 1s2s ^3S to 1s2p ^3P transition of the ^4He atom. The experiment described in this thesis is the first one in which laser spectroscopy has been done on the 2 ^3S to 2^3 P transition in a metastable atomic beam. The energy interval between the 2^3S and the 2^3P state is precisely determined by comparison of the absolute wavelength of the transition with our standard laser (an iodine stabilized He-Ne laser with an accuracy of 1.6 parts in 10^{10 }) in a Fabry-Perot interferometer. The experimental Lamb shift of the transition is determined by subtracting from the measured frequency the precisely known non-quantum electrodynamic contributions to the theoretical value of the interval. From our measurements of the absolute wavelength, the following weighted (2J + 1) average for the 2^3S to 2^3P transition frequency and experimental Lamb Shift are obtained:eqalign{& rm f_{2S{-}2P} = 276 736 495.59 (5) rm MHz.cr& {bf L}[ 2^3Sto2 ^3P] = 5311.26 (5) rm MHz.cr} Our value for the Lamb Shift is in agreement with the best previous measurement but a factor of 60 more precise. It is also two orders of magnitude more precise than the present theoretical calculation, presenting quite a challenge to theorists. Nevertheless, this work is very timely since it is anticipated (DRA94) (MOR94) that the theory will reach this level in the near future. The measured fine structure splittings of the 2^3P level are: eqalign{rm 2^3P_0to rm2^3P_2 &: 31908.135 (3) rm MHzcrrm 2^3P_1to rm2^3P_2 &: sk{5}2291.173 (3) rm MHz}These results are more precise than previous microwave measurements and in significant disagreement with them, a situation which is especially timely and interesting since new theoretical calculations of these fine structure intervals (DRA94) at this level of precision are nearing completion.

  20. Integer ambiguity resolution in precise point positioning: method comparison

    NASA Astrophysics Data System (ADS)

    Geng, Jianghui; Meng, Xiaolin; Dodson, Alan H.; Teferle, Felix N.

    2010-09-01

    Integer ambiguity resolution at a single receiver can be implemented by applying improved satellite products where the fractional-cycle biases (FCBs) have been separated from the integer ambiguities in a network solution. One method to achieve these products is to estimate the FCBs by averaging the fractional parts of the float ambiguity estimates, and the other is to estimate the integer-recovery clocks by fixing the undifferenced ambiguities to integers in advance. In this paper, we theoretically prove the equivalence of the ambiguity-fixed position estimates derived from these two methods by assuming that the FCBs are hardware-dependent and only they are assimilated into the clocks and ambiguities. To verify this equivalence, we implement both methods in the Position and Navigation Data Analyst software to process 1 year of GPS data from a global network of about 350 stations. The mean biases between all daily position estimates derived from these two methods are only 0.2, 0.1 and 0.0 mm, whereas the standard deviations of all position differences are only 1.3, 0.8 and 2.0 mm for the East, North and Up components, respectively. Moreover, the differences of the position repeatabilities are below 0.2 mm on average for all three components. The RMS of the position estimates minus those from the International GNSS Service weekly solutions for the former method differs by below 0.1 mm on average for each component from that for the latter method. Therefore, considering the recognized millimeter-level precision of current GPS-derived daily positions, these statistics empirically demonstrate the theoretical equivalence of the ambiguity-fixed position estimates derived from these two methods. In practice, we note that the former method is compatible with current official clock-generation methods, whereas the latter method is not, but can potentially lead to slightly better positioning quality.

  1. Analysis of flood modeling through innovative geomatic methods

    NASA Astrophysics Data System (ADS)

    Zazo, Santiago; Molina, José-Luis; Rodríguez-Gonzálvez, Pablo

    2015-05-01

    A suitable assessment and management of the exposure level to natural flood risks necessarily requires an exhaustive knowledge of the terrain. This study, primarily aimed to evaluate flood risk, firstly assesses the suitability of an innovative technique, called Reduced Cost Aerial Precision Photogrammetry (RC-APP), based on a motorized technology ultra-light aircraft ULM (Ultra-Light Motor), together with the hybridization of reduced costs sensors, for the acquisition of geospatial information. Consequently, this research generates the RC-APP technique which is found to be a more accurate-precise, economical and less time consuming geomatic product. This technique is applied in river engineering for the geometric modeling and risk assessment to floods. Through the application of RC-APP, a high spatial resolution image (orthophoto of 2.5 cm), and a Digital Elevation Model (DEM) of 0.10 m mesh size and high density points (about 100 points/m2), with altimetric accuracy of -0.02 ± 0.03 m have been obtained. These products have provided a detailed knowledge of the terrain, afterward used for the hydraulic simulation which has allowed a better definition of the inundated area, with important implications for flood risk assessment and management. In this sense, it should be noted that the achieved spatial resolution of DEM is 0.10 m which is especially interesting and useful in hydraulic simulations through 2D software. According to the results, the developed methodology and technology allows for a more accurate riverbed representation, compared with other traditional techniques such as Light Detection and Ranging (LiDAR), with a Root-Mean-Square Error (RMSE ± 0.50 m). This comparison has revealed that RC-APP has one lower magnitude order of error than the LiDAR method. Consequently, this technique arises as an efficient and appropriate tool, especially in areas with high exposure to risk of flooding. In hydraulic terms, the degree of detail achieved in the 3D model, has allowed reaching a significant increase in the knowledge of hydraulic variables in natural waterways.

  2. Development and Validation of a Natural Language Processing Tool to Identify Patients Treated for Pneumonia across VA Emergency Departments.

    PubMed

    Jones, B E; South, B R; Shao, Y; Lu, C C; Leng, J; Sauer, B C; Gundlapalli, A V; Samore, M H; Zeng, Q

    2018-01-01

    Identifying pneumonia using diagnosis codes alone may be insufficient for research on clinical decision making. Natural language processing (NLP) may enable the inclusion of cases missed by diagnosis codes. This article (1) develops a NLP tool that identifies the clinical assertion of pneumonia from physician emergency department (ED) notes, and (2) compares classification methods using diagnosis codes versus NLP against a gold standard of manual chart review to identify patients initially treated for pneumonia. Among a national population of ED visits occurring between 2006 and 2012 across the Veterans Affairs health system, we extracted 811 physician documents containing search terms for pneumonia for training, and 100 random documents for validation. Two reviewers annotated span- and document-level classifications of the clinical assertion of pneumonia. An NLP tool using a support vector machine was trained on the enriched documents. We extracted diagnosis codes assigned in the ED and upon hospital discharge and calculated performance characteristics for diagnosis codes, NLP, and NLP plus diagnosis codes against manual review in training and validation sets. Among the training documents, 51% contained clinical assertions of pneumonia; in the validation set, 9% were classified with pneumonia, of which 100% contained pneumonia search terms. After enriching with search terms, the NLP system alone demonstrated a recall/sensitivity of 0.72 (training) and 0.55 (validation), and a precision/positive predictive value (PPV) of 0.89 (training) and 0.71 (validation). ED-assigned diagnostic codes demonstrated lower recall/sensitivity (0.48 and 0.44) but higher precision/PPV (0.95 in training, 1.0 in validation); the NLP system identified more "possible-treated" cases than diagnostic coding. An approach combining NLP and ED-assigned diagnostic coding classification achieved the best performance (sensitivity 0.89 and PPV 0.80). System-wide application of NLP to clinical text can increase capture of initial diagnostic hypotheses, an important inclusion when studying diagnosis and clinical decision-making under uncertainty. Schattauer GmbH Stuttgart.

  3. Repeatability precision of the falling number procedure under standard and modified methodologies

    USDA-ARS?s Scientific Manuscript database

    The falling number (FN) procedure is used worldwide to assess the integrity of the starch stored within wheat seed. As an indirect measurement of the activity level of alpha-amylase, FN relies on a dedicated viscometer that measures the amount of time needed for a metal stirring rod of precise geome...

  4. Case Study: Meeting the Demand for Skilled Precision Engineers

    ERIC Educational Resources Information Center

    Sansom, Chris; Shore, Paul

    2008-01-01

    Purpose: This paper aims to demonstrate how science and engineering graduates can be recruited and trained to Masters level in precision engineering as an aid to reducing the skills shortage of mechanical engineers in UK industry. Design/methodology/approach: The paper describes a partnership between three UK academic institutions and industry,…

  5. Overcoming Barriers to Using Precision Teaching with a Web-Based Programme

    ERIC Educational Resources Information Center

    Hayes, Ben; Heather, Andrew; Jones, Daniel; Clarke, Christopher

    2018-01-01

    Precision Teaching (PT) is an evidence-based intervention, which research indicates is frequently not implemented following training, with few teachers using it in schools after training events. The web-based programme in this research focuses on word-level reading skills and targets blending and segmenting skills rather than whole word reading.…

  6. High-throughput dual-colour precision imaging for brain-wide connectome with cytoarchitectonic landmarks at the cellular level

    PubMed Central

    Gong, Hui; Xu, Dongli; Yuan, Jing; Li, Xiangning; Guo, Congdi; Peng, Jie; Li, Yuxin; Schwarz, Lindsay A.; Li, Anan; Hu, Bihe; Xiong, Benyi; Sun, Qingtao; Zhang, Yalun; Liu, Jiepeng; Zhong, Qiuyuan; Xu, Tonghui; Zeng, Shaoqun; Luo, Qingming

    2016-01-01

    The precise annotation and accurate identification of neural structures are prerequisites for studying mammalian brain function. The orientation of neurons and neural circuits is usually determined by mapping brain images to coarse axial-sampling planar reference atlases. However, individual differences at the cellular level likely lead to position errors and an inability to orient neural projections at single-cell resolution. Here, we present a high-throughput precision imaging method that can acquire a co-localized brain-wide data set of both fluorescent-labelled neurons and counterstained cell bodies at a voxel size of 0.32 × 0.32 × 2.0 μm in 3 days for a single mouse brain. We acquire mouse whole-brain imaging data sets of multiple types of neurons and projections with anatomical annotation at single-neuron resolution. The results show that the simultaneous acquisition of labelled neural structures and cytoarchitecture reference in the same brain greatly facilitates precise tracing of long-range projections and accurate locating of nuclei. PMID:27374071

  7. A rubidium traced white-light etalon calibrator for MAROON-X

    NASA Astrophysics Data System (ADS)

    Stürmer, Julian; Seifahrt, Andreas; Schwab, Christian; Bean, Jacob L.

    2016-07-01

    We report on the construction and testing of a vacuum-gap Fabry-Perot etalon calibrator for high precision radial velocity spectrographs. The etalon is referenced against hyper fine transitions of rubidium to provide a precise wavelength calibrator for MAROON-X, a new fiber-fed, red-optical, high-precision radial-velocity spectrograph currently under construction for one of the twin 6.5m Magellan Telescopes in Chile. We demonstrate a turnkey system, ready to be installed at any current and next generation radial velocity spectrograph that requires calibration over a wide spectral band-pass. Uncertainties in the position of one etalon line are at the 10 cm s-1 level in individual measurements taken at 4 Hz. Our long-term stability is mainly limited by aging effects of the spacer material Zerodur, which imprints a 12 cm s-1 daily drift. However, as the etalon position is traced by the rubidium reference with a precision of <3 cm s-1 for integration times longer than 10s, we can fully account for this effect at the RV data reduction level.

  8. Short-sheeting the psychiatric bed: state-level strategies to curtail the unnecessary hospitalization of adolescents in for-profit mental health facilities.

    PubMed

    Sperber, M N

    1992-01-01

    Over the past decade, there has been an increase in the hospitalization of minors in private, for-profit, psychiatric facilities. This increase suggests a tension between what is medically necessary and what is financially desirable. This Note discusses the hospitalization of minors in private, for-profit, mental health facilities and its attendant implications. This Note then examines various state efforts aimed at protecting minors from inappropriate psychiatric hospitalization. Finally, while there is no catch-all solution to the problem, this Note offers specific recommendations for reforming the for-profit psychiatric industry.

  9. Analysis of Factors Affecting Output Levels and Frequencies of MP3 Players.

    PubMed

    Kim, Jinsook

    2013-09-01

    Exposure to high levels of music that could lead to music induced hearing loss (MIHL) has been of recent interest especially for young adults, considering their excessive use of personal listening devices such as MP3 player. More attention should be drawn to MIHL for noting that early noise exposure leads to earlier onset of presbycusis. In search of appropriate and safe listening habits for young adults, this investigation was aimed to evaluate output levels and frequencies generated by the Samsung galaxy note MP3 player depending on two earphone types; ear-bud and over-the-ear earphones and three music genres; rock, hip-hop, ballade. A sound level meter was used to measure output level and frequency spectrum between 12.5 and 16000 Hz at all 1/3-octave bands. The following results can be summarized. 1) The earphone styles did not produce significant difference in output levels, but the music genres did. However, the results of music genres varied. 2) Neither earphone styles nor music genres produced significant difference in frequency response spectrum, except music genres at the volume settings we usually listen to. Additionally, volume levels should be lower than 50% for usual listening situation. Through this investigation, it was noted that the frequency range was substantial between 50 and 1000 Hz regardless of the styles of earphones and music genres, implying that we should be cautious of this frequency range when we listen to music. Researchers should give more attention to the effects of the mixture of output level and frequency spectrum, considering that the auditory system has frequency specificity from the periphery to the central to provide refined methods for protecting our ears from MIHL.

  10. Analysis of Factors Affecting Output Levels and Frequencies of MP3 Players

    PubMed Central

    2013-01-01

    Exposure to high levels of music that could lead to music induced hearing loss (MIHL) has been of recent interest especially for young adults, considering their excessive use of personal listening devices such as MP3 player. More attention should be drawn to MIHL for noting that early noise exposure leads to earlier onset of presbycusis. In search of appropriate and safe listening habits for young adults, this investigation was aimed to evaluate output levels and frequencies generated by the Samsung galaxy note MP3 player depending on two earphone types; ear-bud and over-the-ear earphones and three music genres; rock, hip-hop, ballade. A sound level meter was used to measure output level and frequency spectrum between 12.5 and 16000 Hz at all 1/3-octave bands. The following results can be summarized. 1) The earphone styles did not produce significant difference in output levels, but the music genres did. However, the results of music genres varied. 2) Neither earphone styles nor music genres produced significant difference in frequency response spectrum, except music genres at the volume settings we usually listen to. Additionally, volume levels should be lower than 50% for usual listening situation. Through this investigation, it was noted that the frequency range was substantial between 50 and 1000 Hz regardless of the styles of earphones and music genres, implying that we should be cautious of this frequency range when we listen to music. Researchers should give more attention to the effects of the mixture of output level and frequency spectrum, considering that the auditory system has frequency specificity from the periphery to the central to provide refined methods for protecting our ears from MIHL. PMID:24653908

  11. The effects of natural language processing on cross-institutional portability of influenza case detection for disease surveillance.

    PubMed

    Ferraro, Jeffrey P; Ye, Ye; Gesteland, Per H; Haug, Peter J; Tsui, Fuchiang Rich; Cooper, Gregory F; Van Bree, Rudy; Ginter, Thomas; Nowalk, Andrew J; Wagner, Michael

    2017-05-31

    This study evaluates the accuracy and portability of a natural language processing (NLP) tool for extracting clinical findings of influenza from clinical notes across two large healthcare systems. Effectiveness is evaluated on how well NLP supports downstream influenza case-detection for disease surveillance. We independently developed two NLP parsers, one at Intermountain Healthcare (IH) in Utah and the other at University of Pittsburgh Medical Center (UPMC) using local clinical notes from emergency department (ED) encounters of influenza. We measured NLP parser performance for the presence and absence of 70 clinical findings indicative of influenza. We then developed Bayesian network models from NLP processed reports and tested their ability to discriminate among cases of (1) influenza, (2) non-influenza influenza-like illness (NI-ILI), and (3) 'other' diagnosis. On Intermountain Healthcare reports, recall and precision of the IH NLP parser were 0.71 and 0.75, respectively, and UPMC NLP parser, 0.67 and 0.79. On University of Pittsburgh Medical Center reports, recall and precision of the UPMC NLP parser were 0.73 and 0.80, respectively, and IH NLP parser, 0.53 and 0.80. Bayesian case-detection performance measured by AUROC for influenza versus non-influenza on Intermountain Healthcare cases was 0.93 (using IH NLP parser) and 0.93 (using UPMC NLP parser). Case-detection on University of Pittsburgh Medical Center cases was 0.95 (using UPMC NLP parser) and 0.83 (using IH NLP parser). For influenza versus NI-ILI on Intermountain Healthcare cases performance was 0.70 (using IH NLP parser) and 0.76 (using UPMC NLP parser). On University of Pisstburgh Medical Center cases, 0.76 (using UPMC NLP parser) and 0.65 (using IH NLP parser). In all but one instance (influenza versus NI-ILI using IH cases), local parsers were more effective at supporting case-detection although performances of non-local parsers were reasonable.

  12. High-Precision Image Aided Inertial Navigation with Known Features: Observability Analysis and Performance Evaluation

    PubMed Central

    Jiang, Weiping; Wang, Li; Niu, Xiaoji; Zhang, Quan; Zhang, Hui; Tang, Min; Hu, Xiangyun

    2014-01-01

    A high-precision image-aided inertial navigation system (INS) is proposed as an alternative to the carrier-phase-based differential Global Navigation Satellite Systems (CDGNSSs) when satellite-based navigation systems are unavailable. In this paper, the image/INS integrated algorithm is modeled by a tightly-coupled iterative extended Kalman filter (IEKF). Tightly-coupled integration ensures that the integrated system is reliable, even if few known feature points (i.e., less than three) are observed in the images. A new global observability analysis of this tightly-coupled integration is presented to guarantee that the system is observable under the necessary conditions. The analysis conclusions were verified by simulations and field tests. The field tests also indicate that high-precision position (centimeter-level) and attitude (half-degree-level)-integrated solutions can be achieved in a global reference. PMID:25330046

  13. Pico-coulomb charge measured at BELLA to percent-level precision using a Turbo-ICT

    NASA Astrophysics Data System (ADS)

    Nakamura, K.; Mittelberger, D. E.; Gonsalves, A. J.; Daniels, J.; Mao, H.-S.; Stulle, F.; Bergoz, J.; Leemans, W. P.

    2016-03-01

    Precise diagnostics of picocoulomb level particle bunches produced by laser plasma accelerators (LPAs) can be a significant challenge. Without proper care, the small signals associated with such bunches can be dominated by a background generated by laser, target, laser-plasma interaction and particle induced radiation. In this paper, we report on first charge measurements using the newly developed Turbo-ICT for LPAs. We outline the Turbo-ICT working principle, which allows precise sub-picocoulomb measurements even in the presence of significant background signals. A comparison of the Turbo-ICT, a conventional integrating current transformer (ICT) and a scintillating screen (Lanex) was carried out at the Berkeley Lab Laser Accelerator. Results show that the Turbo-ICT can measure sub-picocoulomb charge accurately and has significantly improved noise immunity compared to the ICT.

  14. Media reporting on research presented at scientific meetings: more caution needed.

    PubMed

    Woloshin, Steven; Schwartz, Lisa M

    2006-06-05

    To examine media stories on research presented at scientific meetings to see if they reported basic study facts and cautions, and whether they were clear about the preliminary stage of the research. Three physicians with clinical epidemiology training analysed front-page newspaper stories (n = 32), other newspaper stories (n = 142), and television/radio stories (n = 13) identified in LexisNexis and ProQuest searches for research reports from five scientific meetings in 2002-2003 (American Heart Association, 14th Annual International AIDS Conference, American Society of Clinical Oncology, Society for Neuroscience, and the Radiological Society of North America). Media reporting of basic study facts (size, design, quantification of results); cautions about study designs with intrinsic limitations (animal/laboratory studies, studies with < 30 people, uncontrolled studies, controlled but not randomised studies) or downsides (adverse effects in intervention studies); warnings about the preliminary stage of the research presented at scientific meetings. 34% of the 187 stories did not mention study size, 18% did not mention study design (another 35% were so ambiguous that expert readers had to guess the design), and 40% did not quantify the main result. Only 6% of news stories about animal studies mentioned their limited relevance to human health; 21% of stories about small studies noted problems with the precision of the finding; 10% of stories about uncontrolled studies noted it was not possible to know if the outcome really related to the exposure; and 19% of stories about controlled but not randomised studies raised the possibility of confounding. Only 29% of the 142 news stories on intervention studies noted the possibility of any potential downside. Twelve stories mentioned a corresponding "in press" medical journal article; two of the remaining 175 noted that findings were unpublished, might not have undergone peer review, or might change. News stories about scientific meeting research presentations often omit basic study facts and cautions. Consequently, the public may be misled about the validity and relevance of the science presented.

  15. Precise time transfer using MKIII VLBI technology

    NASA Technical Reports Server (NTRS)

    Johnston, K. J.; Buisson, J. A.; Lister, M. J.; Oaks, O. J.; Spencer, J. H.; Waltman, W. B.; Elgered, G.; Lundqvist, G.; Rogers, A. E. E.; Clark, T. A.

    1984-01-01

    It is well known that Very Long Baseline Interferometry (VLBI) is capable of precise time synchronization at subnanosecond levels. This paper deals with a demonstration of clock synchronization using the MKIII VBLI system. The results are compared with clock synchronization by traveling cesium clocks and GPS. The comparison agrees within the errors of the portable clocks (+ 5 ns) and GPS(+ or - 30 ns) systems. The MKIII technology appears to be capable of clock synchronization at subnanosecond levels and appears to be very good benchmark system against which future time synchronization systems can be evaluated.

  16. Controlling and policing substance use(rs).

    PubMed

    White, Tony

    2002-01-01

    Controlling drug use--a dynamic, global, politicalized process--is reviewed in terms of selected types of drugs, "natural levels" of drug demand and use, drug markets and the drug market environment, types of traffickers, illicit drug trade profits, approaches to drug control ("War on Drugs", "Zero Tolerance" programs and policies, "normalizing" and legalizing selected drugs), including UN's then relatively recent "Balanced Approach" and facets of drug law enforcement (drug prices and purity levels and values of drug seizures), including various rarely noted benefits to intervention programs and control agents. Unresolved issues and needed "tools" are noted while considering the implications of the first UN's World Drug Report data.

  17. Experience affects immediate early gene expression in response to conspecific call notes in black-capped chickadees (Poecile atricapillus).

    PubMed

    Hahn, Allison H; Guillette, Lauren M; Lee, Daniel; McMillan, Neil; Hoang, John; Sturdy, Christopher B

    2015-01-01

    Black-capped chickadees (Poecile atricapillus) produce numerous vocalizations, including the acoustically complex chick-a-dee call that is composed of A, B, C, and D notes. D notes are longer in duration and lower in frequency than the other note types and contain information regarding flock and species identification. Adult wild-caught black-capped chickadees have been shown to have similar amounts of immediate early gene (IEG) expression following playback of vocalizations with harmonic-like acoustic structure, similar to D notes. Here we examined how different environmental experiences affect IEG response to conspecific D notes. We hand-reared black-capped chickadees under three conditions: (1) with adult conspecifics, (2) with adult heterospecific mountain chickadees, and (3) without adults. We presented all hand-reared birds and a control group of field-reared black-capped chickadees, with conspecific D notes and quantified IEG expression in the caudomedial mesopallium (CMM) and caudomedial nidopallium (NCM). We found that field-reared birds that heard normal D notes had a similar neural response as a group of field-reared birds that heard playback of reversed D notes. Field-reared birds that heard normal D notes also had a similar neural response as birds reared with adult conspecifics. Birds reared without adults had a significantly reduced IEG response, whereas the IEG expression in birds reared with heterospecifics was at intermediate levels between birds reared with conspecifics and birds reared without adults. Although acoustic characteristics have been shown to drive IEG expression, our results demonstrate that experience with adults or normal adult vocalizations is also an important factor. Copyright © 2015 Elsevier B.V. All rights reserved.

  18. Assessment of the Validity and Reproducibility of a Novel Standardized Test Meal for the Study of Postprandial Triacylglycerol Concentrations.

    PubMed

    Tentolouris, Nikolaos; Kanellos, Panagiotis T; Siami, Evangelia; Athanasopoulou, Elpida; Chaviaras, Nikolaos; Kolovou, Genovefa; Sfikakis, Petros P; Katsilambros, Nikolaos

    2017-08-01

    Lipotest ® is a standardized fat-rich meal designed for use as a test meal during a fat tolerance test (FTT) for the study of postprandial triacylglycerol (TAG) concentrations. Herein we examined the precision and reproducibility of examination using Lipotest ® on postprandial TAG levels. A total of 26 healthy consenting subjects were examined twice after 8-10 h fasting with an interval of approximately 1 week apart. Blood samples were collected at baseline and 1, 2, 3, and 4 h after consumption of the test meal for measurement of plasma total TAG levels. We examined agreement, precision, and accuracy between the two visits using the Altman plots and correlation coefficient. Reproducibility was tested using the coefficient of variation (CV) and intraclass correlation coefficient (ICC). Moreover, the area under the curve (AUC) as a summary measure of the overall postprandial TAG levels was calculated. The agreement, precision (r ≥ 0.74, p < 0.001), and accuracy (≥0.99) between the measurements in plasma TAG during Lipotest ® testing in the two visits were high. In terms of reproducibility, the values of CV were 15.59-23.83% while those of ICC were ≥0.75. The values of the AUCs in the visits were not different (p = 0.87). A single measurement of plasma TAG levels at 4 h after Lipotest ® consumption depicted peak postprandial TAG concentration. A FTT using Lipotest ® as a standardized meal has good precision and reproducibility for the study of postprandial TAG levels in healthy individuals. A single determination of plasma TAG concentration at 4 h after Lipotest ® consumption captures peak postprandial TAG response.

  19. Analysis on bilateral hindlimb mapping in motor cortex of the rat by an intracortical microstimulation method.

    PubMed

    Seong, Han Yu; Cho, Ji Young; Choi, Byeong Sam; Min, Joong Kee; Kim, Yong Hwan; Roh, Sung Woo; Kim, Jeong Hoon; Jeon, Sang Ryong

    2014-04-01

    Intracortical microstimulation (ICMS) is a technique that was developed to derive movement representation of the motor cortex. Although rats are now commonly used in motor mapping studies, the precise characteristics of rat motor map, including symmetry and consistency across animals, and the possibility of repeated stimulation have not yet been established. We performed bilateral hindlimb mapping of motor cortex in six Sprague-Dawley rats using ICMS. ICMS was applied to the left and the right cerebral hemisphere at 0.3 mm intervals vertically and horizontally from the bregma, and any movement of the hindlimbs was noted. The majority (80%± 11%) of responses were not restricted to a single joint, which occurred simultaneously at two or three hindlimb joints. The size and shape of hindlimb motor cortex was variable among rats, but existed on the convex side of the cerebral hemisphere in all rats. The results did not show symmetry according to specific joints in each rats. Conclusively, the hindlimb representation in the rat motor cortex was conveniently mapped using ICMS, but the characteristics and inter-individual variability suggest that precise individual mapping is needed to clarify motor distribution in rats.

  20. Helium Mass Spectrometer Leak Detection: A Method to Quantify Total Measurement Uncertainty

    NASA Technical Reports Server (NTRS)

    Mather, Janice L.; Taylor, Shawn C.

    2015-01-01

    In applications where leak rates of components or systems are evaluated against a leak rate requirement, the uncertainty of the measured leak rate must be included in the reported result. However, in the helium mass spectrometer leak detection method, the sensitivity, or resolution, of the instrument is often the only component of the total measurement uncertainty noted when reporting results. To address this shortfall, a measurement uncertainty analysis method was developed that includes the leak detector unit's resolution, repeatability, hysteresis, and drift, along with the uncertainty associated with the calibration standard. In a step-wise process, the method identifies the bias and precision components of the calibration standard, the measurement correction factor (K-factor), and the leak detector unit. Together these individual contributions to error are combined and the total measurement uncertainty is determined using the root-sum-square method. It was found that the precision component contributes more to the total uncertainty than the bias component, but the bias component is not insignificant. For helium mass spectrometer leak rate tests where unit sensitivity alone is not enough, a thorough evaluation of the measurement uncertainty such as the one presented herein should be performed and reported along with the leak rate value.

Top