Nova Sco 2016 No. 2 = PNV J17225112-3158349 = ASASSN-16kd
NASA Astrophysics Data System (ADS)
Waagen, Elizabeth O.
2016-09-01
AAVSO Alert Notice 550 announces the independent discovery of Nova Sco 2016 No. 2 = ASASSN-16kd = PNV J17225112-3158349 = V1656 Sco by Shigehisa Fujikawa (Kan'onji, Kagawa, Japan) at unfiltered CCD magnitude 11.6 on 2016 September 06.481 UT; and by ASAS-SN (Stanek et al., ATel #9469) at 12.13 V on 2016 September 06.00 UT. Spectroscopy indicating that Nova Sco 2016 No. 2 is a highly reddened classical Fe II-type nova was obtained by Arai and Honda (CBET 4320); by Bohlsen (ATel #9477); by Bersier et al. (ATel #9478); and by Prieto et al. (ATel #9479). Finder charts with sequence may be created using the AAVSO Variable Star Plotter (https://www.aavso.org/vsp). Observations should be submitted to the AAVSO International Database. See full Alert Notice for more details.
MAXI/GSC detection of a possible new X-ray nova MAXI J1621-501 on the galactic plane
NASA Astrophysics Data System (ADS)
Hashimoto, T.; Negoro, H.; Ueno, S.; Tomida, H.; Ishikawa, M.; Sugawara, Y.; Isobe, N.; Shimomukai, R.; Mihara, T.; Sugizaki, M.; Nakahira, S.; Iwakiri, W.; Shidatsu, M.; Yatabe, F.; Takao, Y.; Matsuoka, M.; Kawai, N.; Sugita, S.; Yoshii, T.; Tachibana, Y.; Harita, S.; Morita, K.; Yoshida, A.; Sakamoto, T.; Serino, M.; Kawakubo, Y.; Kitaoka, Y.; Tsunemi, H.; Yoneyama, T.; Nakajima, M.; Kawase, T.; Sakamaki, A.; Ueda, Y.; Hori, T.; Tanimoto, A.; Oda, S.; Tsuboi, Y.; Nakamura, Y.; Sasaki, R.; Kawai, H.; Yamauchi, M.; Hanyu, C.; Hidaka, K.; Kawamuro, T.; Yamaoka, K.
2017-10-01
The MAXI/GSC nova alert system triggered on a bright uncatalogued X-ray transient source at 05:45 UT on 2017 October 19. Using GSC camera GSC_5 data of 4 scan transits from 04:12 to 08:50, we obtain the source position at (R.A., Dec) = (245.260 deg, -50.185 deg) = (16 21 02, -50 11 06) (J2000) with a statistical 90% C.L. elliptical error region with long and short radii of 0.23 deg and 0.22 deg, respectively.
Nova Mus 2018 (PNV J11261220-6531086) Is Forming Dust
NASA Astrophysics Data System (ADS)
Walter, Frederick M.
2018-02-01
Nova Mus 2018 (PNV J11261220-6531086) was discovered by R Kaufman on 2018 Jan 14.486, and reported by P. Schmeer in vsnet-alert 21772. The first detection was 2018 Jan 3.24 (ASAS-SN, reported in the TOCP).
NASA Astrophysics Data System (ADS)
Waagen, Elizabeth O.
2011-08-01
Announcement of discovery of Nova Lupi 2011 = PNV J14542000-5505030. Discovered by Nicholas Brown (Quinns Rocks, Western Australia) on 2011 Aug. 4.73 UT at unfiltered mag=10.2 (tmax 400 film). Posted on the IAU Central Bureau for Astronomical Telegrams Transient Object Confirmation Page (TOCP) as PNV J14542000-5505030. Spectra obtained by Fred Walter (SUNY Stony Brook) 2011 August 9.0132 UT with the SMARTS 1.5m RC spectrograph at Cerro Tololo and reported in ATEL #3536 confirms that the object is an Fe II nova near maximum. Initially announced in [vsnet-alert 13560] (Nicholas Brown) and in AAVSO Special Notice #247 (Arne Henden). Finder charts with sequence may be created using the AAVSO Variable Star Plotter (http://www.aavso.org/vsp). Observations should be submitted to the AAVSO International Database. See full Alert Notice for more details and observations.
MAXI/GSC detection of a new outburst from the black hole candidate H 1743-322
NASA Astrophysics Data System (ADS)
Shidatsu, M.; Nakahira, S.; Negoro, H.; Ueno, S.; Tomida, H.; Ishikawa, M.; Sugawara, Y.; Nakagawa, Y. E.; Mihara, T.; Sugizaki, M.; Serino, M.; Iwakiri, W.; Sugimoto, J.; Takagi, T.; Matsuoka, M.; Kawai, N.; Isobe, N.; Sugita, S.; Yoshii, T.; Tachibana, Y.; Ono, Y.; Fujiwara, T.; Harita, S.; Muraki, Y.; Yoshida, A.; Sakamoto, T.; Kawakubo, Y.; Kitaoka, Y.; Tsunemi, H.; Shomura, R.; Nakajima, M.; Tanaka, K.; Masumitsu, T.; Kawase, T.; Ueda, Y.; Kawamuro, T.; Hori, T.; Tanimoto, A.; Oda, S.; Tsuboi, Y.; Nakamura, Y.; Sasaki, R.; Yamauchi, M.; Furuya, K.; Yamaoka, K.
2016-11-01
The MAXI/GSC nova-alert system detected an X-ray brightening of the Galactic black hole candidate H 1743-322 in November 6, UT 03:01. The 2-20 keV flux increased from 12 +- 3 mCrab on November 4 (MJD 57696) to 37 +- 5 mCrab on November 6 (MJD 57698).
Nova Sagittarii 2014 = PNV J18250860-2236024 AND Erratum
NASA Astrophysics Data System (ADS)
Waagen, Elizabeth O.
2014-02-01
Details of discovery of Nova Sagittarii 2014 (PNV J18250860-2236024) and procedures for observing and reporting observations are announced. Discovered by Sigeru Furuyama (Tone-machi, Ibaraki-ken, Japan) andreported by S. Nakano (Sumoto, Japan) at unfiltered CCD magnitude 8.7 on 2014 Jan. 26.857 UT. Coordinates: R.A. 18 25 08.60 Decl. = -22 36 02.4 (2000.0). Nova Sgr 2014 is Fe II-type classical nova past maximum, per low-resolution spectra obtained by A. Arai on 2014 Jan. 30.87 UT. Announced in IAU CBAT CBET 3802 (D. W. E. Green, ed.). Finder charts with sequence may be created using the AAVSO Variable Star Plotter (http://www.aavso.org/vsp). Observations should be submitted to the AAVSO International Database. See full Alert Notice for more details and observations. Also, an Erratum is reported. In AAVSO Alert Notice 496, Mati Morel (MMAT, Thornton, NSW, Australia) was credited with the discovery of the 1989 outburst of V745 Sco. The discoverer was William Liller (LIW, Vina del Mar, Chile), who observed V745 Sco on 1989 July 30.08 UT at magnitude 9.7 (PROBLICOM discovery using 2415 film with orange filter).
Monitoring of Northern dwarf novae for radio jets campaign
NASA Astrophysics Data System (ADS)
Waagen, Elizabeth O.
2014-10-01
Ms. Deanne Coppejans (PhD candidate, Radboud University Nijmegen (Netherlands) and University of Cape Town) and colleagues have requested AAVSO observer assistance in monitoring nine Northern dwarf novae in support of their campaign to observe them in outburst with the Very Large Array (VLA) to search for radio jets. They will observe 5 targets from the following list: U Gem*, EX Dra, Z Cam*, RX And*, EM Cyg, AB Dra, SY Cnc, SU UMa*, and YZ Cnc*. Stars with an asterisk (*) will be given higher priority. The campaign will begin now, starting with monitoring of RX And and EM Cyg, and run through September 2015, or until all five VLA triggers have been used. This campaign is similar to previous AAVSO campaigns, namely the 2007 campaign to monitor a sample of 10 dwarf novae (AAVSO Alert Notice 345), which resulted in the first detection of a radio jet in a dwarf nova system (Koerding et al. 2008, Science, 320, 1318), and the ones carried out at the request of Dr. James Miller-Jones and colleagues on SS Cyg in 2010-2011 (AAVSO Special Notices #204, #206, Alert Notice 445). The latter resulted in an accurate distance determination to SS Cyg, thereby reconciling its behavior with our understanding of accretion disc theory in accreting compact objects (Miller-Jones et al. 2013, Science, 340, 950). Ms. Coppejans writes: "The relation between accretion and outflow is one of the basic problems in modern astrophysics. It has long been thought that CVs are the only accreting systems that do not produce jets, and this notion has even been used to constrain jet models. However, there are now some indications that CVs do show jets, possibly allowing a universal link between accretion and ejection. Radio observations provide the best unambiguous tracer of the corresponding jet or directed outflow, but there are only two clear detections. By observing a more extensive sample of cataclysmic variables in outburst we will determine the existence of jets or other outflows in these accreting binary systems. These observations will decide if either CVs do show jets and thus support a universal link between accretion and ejection, or if they do not show jets, further constraining future jet models." The radio jet, if it exists in any of these nine systems, is expected to be seen shortly after the beginning of the outburst (as it was in SS Cyg). Catching the outburst as it is just starting and reporting that information to AAVSO HQ immediately is crucial, as the astronomers need to be alerted, make their decision whether to trigger the VLA observations, and allow enough time for the VLA to start the observations. Please observe these systems NIGHTLY (visual, CCD V) and report all observations as soon as is practical. In the event of an outburst, please report your observations as quickly as you can via WebObs, and also notify Dr. Matthew Templeton and Elizabeth Waagen at AAVSO Headquarters and Deanne Coppejans. Finder charts with sequence may be created using the AAVSO Variable Star Plotter (http://www.aavso.org/vsp). Observations should be submitted to the AAVSO International Database. See full Alert Notice for more details and information on the targets.
Nova Centauri 2013 = PNV J13544700-5909080
NASA Astrophysics Data System (ADS)
Waagen, Elizabeth O.
2013-12-01
Announces the discovery of V1369 Cen = Nova Cen 2013 = PNV J13544700-5909080 by John Seach (Chatsworth Island, NSW, Australia) at unfiltered magnitude 5.5 on 2013 December 02.692 UT. Low-resolution spectra obtained by Locke on Dec. 03.3776 UT and by Kaufman on Dec. 03.621 UT show strong Ha and Hb emission lines, indicating the object is a nova. Announced on IAU CBAT Central Bureau Electronic Telegram 3732 (Daniel W. E. Green, ed.). Finder charts with sequences may be created using the AAVSO Variable Star Plotter (http://www.aavso.org/vsp). Observations should be submitted to the AAVSO International Database. See full Alert Notice for more details and observations.
NASA Astrophysics Data System (ADS)
Templeton, Matthew R.
2009-08-01
Nova Ophiuchi 2009 was discovered by Koichi Itagaki, Teppo-Cho, Yamagata, Japan, at unfiltered CCD magnitude 10.1 on August 16.515 UT, and confirmed by him on Aug. 16.526. After posting to the CBET Unconfirmed Observations page, the object was confirmed independently by several observers. The discovery and confirmatory information were intially reported in CBET 1910, CBET 1911, and AAVSO Special Notice #166. The nova, located in a very crowded field within the Milky Way, is reported by T. Kato (vsnet-alert 11399) to have a large B-V (+1.6), indicating it is highly reddened. N Oph 2009 has been assigned the identifiers VSX J173819.7-264413 and the AUID 000-BJP-605. Please submit observations to the AAVSO International Database using the name N OPH 2009.
NASA Astrophysics Data System (ADS)
Metzger, E. P.; Ambos, E. L.; Ng, E. W.; Skiles, J.; Simila, G.; Garfield, N.
2002-05-01
Project ALERT (Augmented Learning Environment and Renewable Teaching) was founded in 1998, with funding from NASA and the California State University (CSU), to improve earth system science education for pre-service teachers. Project ALERT has formed linkages between ten campuses of the CSU, which prepares about 60 percent of California's teachers, and two NASA centers, Ames Research Center and the Jet Propulsion Laboratory. ALERT has also fostered alliances between earth science and science education faculty. The combined expertise of Project ALERT's diverse partners has led to a wide array of activities and products, including: 1) incorporation in university classrooms of NASA-developed imagery, data, and educational resources; 2) creation and/or enhancement of several courses that bring earth systems science to pre-service teachers; 3) fellowships for CSU faculty to participate in collaborative research and education projects at the NASA Centers; 4) development of teaching modules on such varied topics as volcanoes, landslides, and paleoclimate; and 5) a central web site that highlights resources for teaching introductory Earth system science. An outgrowth of Project ALERT is the increased interest on the part of CSU earth scientists in education issues. This has catalyzed their participation in other projects, including NASA's Project NOVA, Earth System Science Education Alliance, and Sun-Earth Connection Education Forum, the Digital Library for Earth System Science Education, and the California Science Project. Project ALERT has also expanded to provide professional development opportunities for in-service teachers, as exemplified by its support of the Bay Area Earth Science Institute (BAESI) at San Jose State University. Each year, BAESI offers 10-15 full-day workshops that supply teachers and teachers-to-be with a blend of science concepts and classroom activities, free instructional materials, and the opportunity to earn inexpensive university credit. These workshops have been enriched by the incorporation of earth and space science information and curricular materials from NASA. In addition, visits to Ames Research Center have given BAESI participants an opportunity to explore the Educator Resource Center, learn about NASA's programs for teachers and students, and experience presentations by NASA scientists engaged in cutting edge research about the earth system. Project ALERT demonstrates the power of a state-based partnership that unites scientists and educators with diverse perspectives and strengths in a synergistic effort to improve science education.
Nova Scorpii 2011 = PNV J16551100-3838120
NASA Astrophysics Data System (ADS)
Waagen, Elizabeth O.
2011-06-01
Announces the discovery of Nova Scorpii 2011 = PNV J16551100-3838120 by John Seach (Chatsworth Island, NSW, Australia) on 2011 June 1.40 UT at magnitude 9.5 (DSLR + orange filter). Spectra by Bernard Heathcote (South Yarra, Vic, Australia) on Jun 2.4896 UT, A. Arai, T. Kajikawa, and M. Nagashima (Kyoto Sangyo University, Japan) on 2011 June 2.68 UT, and Masayuki Yamanaka and Ryosuke Itoh (Hiroshima University, Japan) on Jun 2 UT indicate a highly-reddened classical nova. Initially reported to the AAVSO by Seach and announced in AAVSO Special Notice #240 (Arne Henden) and IAU CBET 2735 (Daniel W. E. Green, ed.). The object was designated PNV J18102135-2305306 when posted on the Central Bureau's Transient Objects Confirmation Page (TOCP) webpage. Finder charts with sequence may be created using the AAVSO Variable Star Plotter (http://www.aavso.org/vsp). Observations should be submitted to the AAVSO International Database. See full Alert Notice for more details, observations, and links to images. [Nova Sco 2011 subsequently assigned the name V1312 Sco
NASA Astrophysics Data System (ADS)
Waagen, Elizabeth O.
2005-06-01
AAVSO Alert Notice 317 has three topics. First: Drs. Christopher Mauche (Lawrence Livermore National Laboratory), Peter Wheatley (Univ. of Leicester), and Koji Mukai (NASA GSFC) have obtained time on XMM-Newton to observe HT Cas, Z Cha, or OY Car in outburst. AAVSO assistance is requested in monitoring these stars closely so we can inform them promptly when any of them go into outburst. Very prompt notification is essential, because the satellite requires 2-4 days to move to the target after the observations are triggered, and the superoutbursts of OY Car and Z Cha last only about 10 days, while the HT Cas outbursts last only a little more than 2 days. Second: Dr. Darren Baskill (Univ. of Leicester) has requested optical observations of LS Peg (currently suspected as being a DQ Her nova-like) to coincide with upcoming observations by XMM-Newton. Observations are requested from now until July 8, with time series 12 hours before and after, and also during the XMM observation. Use an Ic or V filter (Ic preferred), maximum time precision, S/N=100. Third: Dr. Alon Retter (Penn State Univ.) has requested AAVSO assistance in observing V378 Ser (Nova Serpentis 2005). Please monitor V378 Ser over the coming weeks as the nova fades and report your observations to the AAVSO. Both visual and CCD observations are encouraged. Finder charts with sequence may be created using the AAVSO Variable Star Plotter (https://www.aavso.org/vsp). Observations should be submitted to the AAVSO International Database. See full Alert Notice for more details.
MAXI/GSC detection of a probable new X-ray transient MAXI J1820+070
NASA Astrophysics Data System (ADS)
Kawamuro, T.; Negoro, H.; Yoneyama, T.; Ueno, S.; Tomida, H.; Ishikawa, M.; Sugawara, Y.; Isobe, N.; Shimomukai, R.; Mihara, T.; Sugizaki, M.; Nakahira, S.; Iwakiri, W.; Yatabe, F.; Takao, Y.; Matsuoka, M.; Kawai, N.; Sugita, S.; Yoshii, T.; Tachibana, Y.; Harita, S.; Morita, K.; Yoshida, A.; Sakamoto, T.; Serino, M.; Kawakubo, Y.; Kitaoka, Y.; Hashimoto, T.; Tsunemi, H.; Nakajima, M.; Kawase, T.; Sakamaki, A.; Maruyama, W.; Ueda, Y.; Hori, T.; Tanimoto, A.; Oda, S.; Morita, T.; Yamada, S.; Tsuboi, Y.; Nakamura, Y.; Sasaki, R.; Kawai, H.; Sato, T.; Yamauchi, M.; Hanyu, C.; Hidaka, K.; Yamaoka, K.; Shidatsu, M.
2018-03-01
The MAXI/GSC nova alert system triggered on a bright uncatalogued X-ray transient source at 12:50 UT on 2018 March 11. Using GSC camera GSC_2 and GSC_7 data of 5 scan transits from 2018-03-11 19:48 to 2018-03-12 02:04, we obtain the source position at (R.A., Dec) = (275.112 deg, 7.037 deg) = (18 20 26, +07 02 13) (J2000) with a statistical 90% C.L. elliptical error region with long and short radii of 0.47 deg and 0.38 deg, respectively.
MAXI/GSC discovery of a new X-ray transient MAXI J1727-203
NASA Astrophysics Data System (ADS)
Yoneyama, T.; Negoro, H.; Nakajima, M.; Sakamaki, A.; Maruyama, W.; Mihara, T.; Nakahira, S.; Yatabe, F.; Takao, Y.; Matsuoka, M.; Kawai, N.; Sugizaki, M.; Tachibana, Y.; Morita, K.; Sakamoto, T.; Serino, M.; Sugita, S.; Kawakubo, Y.; Hashimoto, T.; Yoshida, A.; Ueno, S.; Tomida, H.; Ishikawa, M.; Isobe, N.; Sugawara, Y.; Shimomukai, R.; Ueda, Y.; Tanimoto, A.; Morita, T.; Yamada, S.; Tsuboi, Y.; Iwakiri, W.; Sasaki, R.; Kawai, H.; Sato, T.; Tsunemi, H.; Yamauchi, M.; Hidaka, K.; Iwahori, S.; Kawamuro, T.; Yamaoka, K.; Shidatsu, M.
2018-06-01
The MAXI/GSC nova alert system (Negoro et al. 2016, PASJ, 68, S1) triggered on an uncatalogued X-ray transient source at 09:41 UT on 2018 June 05. Assuming that the source flux was constant over three scan transits from 9:41 to 12:46, we obtain the source position at (R.A., Dec) = (261.971 deg, -20.389 deg) = (17 27 53, -20 23 20) (J2000) with a statistical 90% C.L. elliptical error region with long and short radii of 0.33 deg and 0.28 deg, respectively.
Nova Sco 2011 No. 2 = PNV J16364440-4132340 = PNV J16364300-4132460
NASA Astrophysics Data System (ADS)
Waagen, Elizabeth O.
2011-09-01
Announcement of discovery of Nova Sco 2011 No. 2 = PNV J16364440-4132340 = PNV J16364300-4132460. Discovered independently by John Seach (Chatsworth Island, NSW, Australia, on 2011 Sep. 06.37 UT at mag=9.8 (DSLR)) and by Yuji Nakamura (Kameyama, Mie, Japan, on 2011 Sep. 06.4313 UT at mag=9.7 C (CCD)). Posted on the IAU Central Bureau for Astronomical Telegrams Transient Object Confirmation Page (TOCP) as PNV J16364440-4132340 (Nakamura) and PNV J16364300-4132460 (Seach); identifications consolidated in VSX under PNV J16364440-4132340. Spectra obtained by A. Arai et al. on 2011 Sep. 7.42 UT suggest a highly reddened Fe II-type classical nova. Spectra by F. Walter and J. Seron obtained Sep. 2011 8.091 UT confirm a young galactic nova; they report spectra are reminiscent of an early recurrent nova. Initially announced in AAVSO Special Notice #251 (Matthew Templeton) and IAU Central Bureau Electronic Telegram 2813 (Daniel W. E. Green, ed.). Finder charts with sequence may be created using the AAVSO Variable Star Plotter (http://www.aavso.org/vsp). Observations should be submitted to the AAVSO International Database. See full Alert Notice for more details and observations.
USDA Forest Service; Maine Forest Service; National Park Service
2002-01-01
The browntail moth, Euproctis chrysorrhoea, a native of Europe, was first found in North America in Somerville, Massachusetts, in the spring of 1897. The lack of natural control agents contributed to its rapid spread throughout the Northeast. By 1915, the moth's range included most of the area east of the Connecticut River and as far north as Nova Scotia....
V5588 SGR = Nova Sagittarii 2011 No. 2 = Pnv J18102135-2305306
NASA Astrophysics Data System (ADS)
Waagen, Elizabeth O.
2011-04-01
Announces the discovery of Nova Sgr 2011 No. 2 = V5588 SGR = PNV J18102135-2305306 by Koichi Nishiyama (Kurume, Japan) and Fujio Kabashima (Miyaki, Japan) on ~ 2011 March 27.832 UT at unfiltered CCD magnitude mag 11.7. Spectra obtained by A. Arai, M. Nagashima, T. Kajikawa, and C. Naka (Koyama Astronomical Observatory, Kyoto Sangyo University) on Mar. 28.725 UT suggest that the object is a classical nova reddened by interstellar matter. The object was designated PNV J18102135-2305306 when posted on the Central Bureau's Transient Objects Confirmation Page (TOCP) webpage. E. Kazarovets, on behalf of the GCVS team, reports that the name V5588 Sgr has been assigned to this nova. It was nitially announced in CBET 2679 (Daniel W. E. Green, ed.) and AAVSO Special Notice #237 (Waagen). Additional information published in IAU Circular 9203 (Green, ed.). Finder charts with sequence may be created using the AAVSO Variable Star Plotter (http://www.aavso.org/vsp). Observations should be submitted to the AAVSO International Database. See full Alert Notice for more details and observations.
NASA Astrophysics Data System (ADS)
Waagen, Elizabeth O.
2007-06-01
Nova Normae 2007 was discovered photographically by William Liller on June 15.086 UT at magnitude 9.4. Precise position measured by G. Bolt from his unfiltered CCD image of June 16.7 UT: 16:32:11.51 -45:09:13.4 (2000.0). Giorgio Di Scala reported to the AAVSO that a low-resolution spectrum indicates a nova a week or so after outburst, with strong H-alpha emission. E. Kazarovets, Sternberg Astronomical Institute, reports that N Nor 07 has been assigned the name V390 Nor. Discovery originally announced in IAU Central Bureau Electronic Telegram 982 (Daniel W. E. Green) and AAVSO Special Notice #49 (Arne Henden). Information in this Alert Notice was received at AAVSO from William Liller, Giorgio Di Scala, or via IAU Circular No. 8850, ed. Daniel W. E. Green. A chart for V390 Nor is available via the Variable Star Plotter (VSP). Go to: http://www.aavso.org/observing/charts/vsp/ and enter the name V390 NOR.
IM Nor monitoring requested for HST COS observations
NASA Astrophysics Data System (ADS)
Waagen, Elizabeth O.
2017-02-01
Dr. Ed Sion (Villanova University) and colleagues have requested AAVSO observers' assistance in monitoring the symbiotic-type recurrent nova IM Nor in support of observations with the Hubble Space Telescope Cosmic Origins Spectrograph scheduled for 2017 February 13 - 17 UT. These observations are part of a study on short orbital period recurrent novae as Supernovae Type Ia progenitors. It is essential to know 24 hours prior to the HST COS observations that IM Nor is not in outburst, in order to protect the instrumentation. Also, photometry is needed throughout the HST window to insure knowledge of the brightness of the system. Observers are asked to monitor IM Nor with nightly snapshot images (V preferred) from now through February 20, and to report their observations promptly. It will be especially important to know the brightness of IM Nor each night through February 17 UT. Finder charts with sequence may be created using the AAVSO Variable Star Plotter (https://www.aavso.org/vsp). Observations should be submitted to the AAVSO International Database. See full Alert Notice for more details.
SNEWS The SuperNova Early Warning System
NASA Astrophysics Data System (ADS)
SNEWS Group
2005-06-01
SNEWS is a cooperative effort between the world's neutrino detection experiments to spread the news that a star in our galaxy has just experienced a core-collapse and is about to be seen as a Supernova. This project exploits the ˜hours time difference between neutrinos promptly escaping the nascent supernova and photons originating when the shock wave breaks through the stellar photosphere, to give the world a chance to get ready to observe such an exciting event at the earliest possible time. A coincidence trigger between experiments is used to eliminate potential local false alarms, allowing a rapid, automated alert. SNEWS is currently operational and ready, and this poster presents the procedures in use.
NR TrA (Nova TrA 2008) monitoring in support of XMM observations
NASA Astrophysics Data System (ADS)
Waagen, Elizabeth O.
2017-03-01
Dr. Fred Walter (Stony Brook University) has requested AAVSO observers' assistance in monitoring NR TrA (Nova TrA 2008) in support of upcoming XMM Newton observations. The XMM observations will take place 2017 March 13 06:21 through March 14 10:34 UT. Walter writes: "NR TrA (Nova TrA 2008) is a compact eclipsing system with a 5.5 hour period. It was a normal Fe II nova that, upon reaching quiescence, took on the appearance of a super-soft source in the optical high state, which suggests an extremely high mass accretion rate. The optical spectrum is dominated by hot permitted lines of O VI, N V, C IV, and He II. Some nova-like variables have similar spectra, though generally without the hot emission lines. Primary eclipse is broad - nearly 40% of the orbit - and deeper at shorter wavelengths, which suggests the eclipse of a hot accretion disk. Primary eclipse depth is about 1 mag at V. There appears to be a shallow secondary eclipse.The primary aim [of the XMM observations] is to detect and characterize the eclipse at X-ray and UV wavelengths. We will obtain low cadence BVRI/JHK observations with SMARTS/Andicam. We request AAVSO support to obtain continuous photometric time series simultaneous with the XMM observation. Any filters are acceptable, but standard Johnson B, V or Cousins R, I are preferred. Clear filters are acceptable. Time resolution better than 5 minutes and uncertainties (outside of eclipse) <0.02 mag are preferred. The best ephemeris I have is: minimum light at JD 55956.822 + 0.219109E. This is based on data from 2013-2015." Finder charts with sequence may be created using the AAVSO Variable Star Plotter (https://www.aavso.org/vsp). Observations should be submitted to the AAVSO International Database. See full Alert Notice for more details.
Outburst of the recurrent nova V745 Sco
NASA Astrophysics Data System (ADS)
Waagen, Elizabeth O.
2014-02-01
The outburst of the recurrent nova V745 Sco (Nova Sco 1937) by Rod Stubbings (Tetoora Road, VIC, Australia) at visual magnitude 9.0 on 2014 February 6.694 UT is reported. This recurrent nova is fading quickly. Follow-up observations of all types (visual, CCD, DSLR) are strongly encouraged, as is spectroscopy; fast time-series of this nova may be useful to detect possible flaring activity as was observed during the outburst of U Scorpii in 2010. Coincident time-series by multiple observers would be most useful for such a study, with a V-filter being preferred. Observations reported to the AAVSO International Database show V745 Sco at visual mag. 10.2 on 2014 Feb. 07.85833 UT (A. Pearce, Nedlands, W. Australia). Finder charts with sequence may be created using the AAVSO Variable Star Plotter (http://www.aavso.org/vsp). Observations should be submitted to the AAVSO International Database. Previous outbursts occurred in 1937 and 1989. The 1937 outburst was detected in 1958 (in decline at magnitude 11.0 on 1937 May 11.1 UT; outburst had occurred within the previous 19 days) by Lukas Plaut on plates taken by Hendrik van Gent at the Leiden Observatory; the object was announced as Nova Sco 1937 and later assigned the GCVS name V745 Sco. The 1989 outburst was detected on 1989 August 1.55 UT by Mati Morel (MMAT, Thornton, NSW, Australia) at visual magnitude 10.4 and in decline. Dr. Bradley Schaefer (Louisiana State University) reports (2010ApJS..187..275S) in his comprehensive analysis of the 10 known galactic recurrent novae (including V745 Sco) that the median interval between recurrent novae outbursts is 24 years. The interval since the 1989 outburst of V745 Sco is 24.10 years. See the Alert Notice for additional visual and multicolor photometry and for more details.
The Explosive Universe with Gaia
NASA Astrophysics Data System (ADS)
Wyrzykowski, Łukasz; Hodgkin, Simon T.; Blagorodnova, Nadejda; Belokurov, Vasily
2014-01-01
The Gaia mission will observe the entire sky for 5 years providing ultra-precise astrometric, photometric and spectroscopic measurements for a billion stars in the Galaxy. Hence, naturally, Gaia becomes an all-sky multi-epoch photometric survey, which will monitor and detect variability with millimag precision as well as new transient sources such as supernovae, novae, microlensing events, tidal disruption events, asteroids, among others. Gaia data-flow allows for quick detections of anomalies within 24-48h after the observation. Such near-real-time survey will be able to detect about 6000 supernovae brighter than 19 mag up to redshifts of Z 0.15. The on-board low-resolution (R 100) spectrograph will allow for early and robust classification of transients and minimise the false-alert rate, even providing the estimates on redshift for supernovae. Gaia will also offer a unique possibility for detecting astrometric shifts in microlensing events, which, combined with Gaia's and ground-based photometry, will provide unique mass measurements of lenses, constrains on the dark matter content in the Milky Way and possible detections of free floating black holes. Alerts from Gaia will be publicly available soon after the detection is verified and tested. First alerts are expected early in 2014 and those will be used for ground-based verification. All facilities are invited to join the verification and the follow-up effort. Alerts will be published on a web page, via Skyalert.org and via emailing list. Each alert will contain coordinates, Gaia light curve and low-resolution spectra, classification and cross-matching results. More information on the Gaia Science Alerts can be found here: http://www.ast.cam.ac.uk/ioa/wikis/gsawgwiki/ The full version of the poster is available here: http://www.ast.cam.ac.uk/ioa/wikis/gsawgwiki/images/1/13/GaiaAlertsPosterIAUS298.pdf
CI Aql monitoring needed to support HST observations
NASA Astrophysics Data System (ADS)
Waagen, Elizabeth O.
2016-10-01
Dr. Edward Sion (Villanova University) has requested AAVSO observers' assistance in monitoring the recurrent nova CI Aql in support of observations with the Hubble Space Telescope Cosmic Origins Spectrograph scheduled for October 31 - November 2, 2016, and November 3 - November 5, 2016. These observations are part of a study on short orbital period recurrent novae as Supernovae Type Ia progenitors. It is essential to know 24 hours prior to the HST COS observations that CI Aql is not in outburst, in order to protect the instrumentation. Observers are asked to keep an eye on CI Aql with nightly snapshot images (V preferred) from now until November 12, and to report their observations promptly. It will be especially important to know the brightness of CI Aql each night for October 28 through November 7 UT. Visual observations are welcome. CI Aql (Nova Aql 1917) has had recurrent outbursts in 1941 and 2000, brightening to V 8.5. At minimum it is V 16-16.5 or fainter. Finder charts with sequence may be created using the AAVSO Variable Star Plotter (https://www.aavso.org/vsp). Observations should be submitted to the AAVSO International Database. See full Alert Notice for more details.
Request to monitor the CV SDSS161033 (1605-00) for HST observations AND TU Cas comparison stars
NASA Astrophysics Data System (ADS)
Price, Aaron
2005-06-01
AAVSO Alert Notice 319 contains two topics. First: Dr. Paula Szkody (University of Washington) has requested AAVSO assistance in monitoring the suspected UGWZ dwarf nova SDSS J161033 [V386 Ser] for upcoming HST observations. This campaign is similar to the one recently run on SDSS J2205 and SDSS J013132 (AAVSO Alert Notice 318). HST mission planners need to be absolutely sure that SDSS J161033 is not in outburst immediately prior to the scheduled observation; AAVSO observations will be crucial to carrying out the HST program. Nightly V observations are requested June 24-July 1 UT. We are making an unusual request in that we are asking for the FITS images themselves to be uploaded to the AAVSO's FTP site. Second: AAVSO Alert Notice 318 did not specify which stars on the TU Cas PEP chart should be used as comparison and check stars. Also, there was an error on the chart regarding the location of the "83" comparison star [the chart that is available online reflects a corrected location]. Please use the "89" and the "74" stars as your comparison and check stars, respectively. Finder charts with sequence may be created using the AAVSO Variable Star Plotter (https://www.aavso.org/vsp). Observations should be submitted to the AAVSO International Database. See full Alert Notice for more details.
NASA Astrophysics Data System (ADS)
Tomaney, Austin Bede
Results are presented from a three year (1987 to 1989) spectroscopic and photometric survey of novae in M3l's bulge, the first comprehensive study of novae outside the Galactic and Magellanic Cloud systems. Nine novae were detected and monitored and their spectra cover a range of outburst states from early decline to the early nebular phases. Broad agreement in spectral morphology and evolution is found with Galactic novae. Since Galactic novae are mainly disk objects, this indicates that novae outburst properties are not critically dependent on the metallicity of the progenitor population. However, in this sample, and in a sample of four M31 nova spectra taken in 1983, no fast, violent outbursts frequently associated with nova systems containing ONeMg white dwarfs were found, suggestive of a systematic difference between the observed proportion of such outbursts between Galactic and M31 bulge novae. Three novae in the sample were observed on succeeding nights during the transition phase of their evolution. Extraordinary variations in some nightly line strengths, particularly the N III lines, were discovered. It is argued that this variability reflects the deposition of drag energy by the secondary star during the common envelope phase of nova evolution and is indicative of a key phase in mass loss from nova systems. Observations include the spectroscopic coverage of an extremely slow nova from 1987 to l990, during the object's evolution in the nebula phase. This provided a unique opportunity to make the first detailed comparison of the evolution and properties of an extra galactic nova with those in our own Galaxy. The roughly solar abundances obtained are typical of similar slow Galactic novae. Further observations are also presented of a unique outburst in 1988 that was independently discovered and reported by Rich et al. These data confirm the inferences of other observers that the outburst differed markedly from that of a typical classical nova. Finally an extensive spectroscopic survey of the M31 globular cluster system was made in an effort to find evidence of a previously suggested enhanced nova rate in these objects. No outbursts were detected during an effective survey time of one year for the entire system.
The awakening of a classical nova from hibernation.
Mróz, Przemek; Udalski, Andrzej; Pietrukowicz, Paweł; Szymański, Michał K; Soszyński, Igor; Wyrzykowski, Łukasz; Poleski, Radosław; Kozłowski, Szymon; Skowron, Jan; Ulaczyk, Krzysztof; Skowron, Dorota; Pawlak, Michał
2016-09-29
Cataclysmic variable stars-novae, dwarf novae, and nova-likes-are close binary systems consisting of a white dwarf star (the primary) that is accreting matter from a low-mass companion star (the secondary). From time to time such systems undergo large-amplitude brightenings. The most spectacular eruptions, with a ten-thousandfold increase in brightness, occur in classical novae and are caused by a thermonuclear runaway on the surface of the white dwarf. Such eruptions are thought to recur on timescales of ten thousand to a million years. In between, the system's properties depend primarily on the mass-transfer rate: if it is lower than a billionth of a solar mass per year, the accretion becomes unstable and the matter is dumped onto the white dwarf during quasi-periodic dwarf nova outbursts. The hibernation hypothesis predicts that nova eruptions strongly affect the mass-transfer rate in the binary, keeping it high for centuries after the event. Subsequently, the mass-transfer rate should significantly decrease for a thousand to a million years, starting the hibernation phase. After that the nova awakes again-with accretion returning to the pre-eruption level and leading to a new nova explosion. The hibernation model predicts cyclical evolution of cataclysmic variables through phases of high and low mass-transfer. The theory gained some support from the discovery of ancient nova shells around the dwarf novae Z Camelopardalis and AT Cancri, but direct evidence for considerable mass-transfer changes prior, during and after nova eruptions has not hitherto been found. Here we report long-term observations of the classical nova V1213 Cen (Nova Centauri 2009) covering its pre- and post-eruption phases and precisely documenting its evolution. Within the six years before the explosion, the system revealed dwarf nova outbursts indicative of a low mass-transfer rate. The post-nova is two orders of magnitude brighter than the pre-nova at minimum light with no trace of dwarf nova behaviour, implying that the mass-transfer rate increased considerably as a result of the nova explosion.
Proper-motion age dating of the progeny of Nova Scorpii AD 1437.
Shara, M M; Iłkiewicz, K; Mikołajewska, J; Pagnotta, A; Bode, M F; Crause, L A; Drozd, K; Faherty, J; Fuentes-Morales, I; Grindlay, J E; Moffat, A F J; Pretorius, M L; Schmidtobreick, L; Stephenson, F R; Tappert, C; Zurek, D
2017-08-30
'Cataclysmic variables' are binary star systems in which one star of the pair is a white dwarf, and which often generate bright and energetic stellar outbursts. Classical novae are one type of outburst: when the white dwarf accretes enough matter from its companion, the resulting hydrogen-rich atmospheric envelope can host a runaway thermonuclear reaction that generates a rapid brightening. Achieving peak luminosities of up to one million times that of the Sun, all classical novae are recurrent, on timescales of months to millennia. During the century before and after an eruption, the 'novalike' binary systems that give rise to classical novae exhibit high rates of mass transfer to their white dwarfs. Another type of outburst is the dwarf nova: these occur in binaries that have stellar masses and periods indistinguishable from those of novalikes but much lower mass-transfer rates, when accretion-disk instabilities drop matter onto the white dwarfs. The co-existence at the same orbital period of novalike binaries and dwarf novae-which are identical but for their widely varying accretion rates-has been a longstanding puzzle. Here we report the recovery of the binary star underlying the classical nova eruption of 11 March AD 1437 (refs 12, 13), and independently confirm its age by proper-motion dating. We show that, almost 500 years after a classical-nova event, the system exhibited dwarf-nova eruptions. The three other oldest recovered classical novae display nova shells, but lack firm post-eruption ages, and are also dwarf novae at present. We conclude that many old novae become dwarf novae for part of the millennia between successive nova eruptions.
Nova V2214 Ophiuchi 1988 - A magnetic nova inside the period gap
NASA Technical Reports Server (NTRS)
Baptista, R.; Jablonski, F. J.; Cieslinski, D.; Steiner, J. E.
1993-01-01
The discovery of a coherent photometric modulation in Nova Oph 1988 with period 0.117515 +/- 0.000002 d, which is associated with the orbital period of the underlying binary, is reported. On the basis of photometric observations, it is concluded that Nova V2214 Oph 1988 is a magnetic nova with an orbital period inside the period gap. The inclusion of this system in the statistics of novae suggests that there is no period gap for novae and that there is a clear correlation between the occurrence of novae with short orbital periods and the presence of magnetic white dwarfs. It is suggested that funneling of the accretion flow onto the magnetic poles favors the conditions for a thermonuclear runaway, increasing the frequency of eruptions for magnetic systems.
Recent progress in understanding the eruptions of classical novae
NASA Technical Reports Server (NTRS)
Shara, Michael M.
1988-01-01
Dramatic progress has occurred in the last two decades in understanding the physical processes and events leading up to, and transpiring during the eruption of a classical nova. The mechanism whereby a white dwarf accreting hydrogen-rich matter from a low-mass main-sequence companion produces a nova eruption has been understood since 1970. The mass-transferring binary stellar configuration leads inexorably to thermonuclear runaways detected at distances of megaparsecs. Summarized here are the efforts of many researchers in understanding the physical processes which generate nova eruptions; the effects upon nova eruptions of different binary-system parameters (e.g., chemical composition or mass of the white dwarf, different mass accretion rates); the possible metamorphosis from dwarf to classical novae and back again; and observational diagnostics of novae, including x ray and gamma ray emission, and the characteristics and distributions of novae in globular clusters and in extragalactic systems. While the thermonuclear-runaway model remains the successful cornerstone of nova simulation, it is now clear that a wide variety of physical processes, and three-dimensional hydrodynamic simulations, will be needed to explain the rich spectrum of behavior observed in erupting novae.
Observations of GAIA-identified Cataclysmic Variables Using the TUBITAK National Observatory
NASA Astrophysics Data System (ADS)
Esenoglu, Hasan H.; Kirbiyik, Halil; Kaynar, Suleyman; Okuyan, Oguzhan; Hamitoglu, Irek; Galeev, Almaz; Uluc, Kadir; Kocak, Murat; Kilic, Sila E.; Parmaksizoglu, Murat; Erece, Orhan; Ozisik, Tuncay; Gulsecen, Hulusi
2016-07-01
TUBITAK National Observatory supports the GAIA alerts with observations using three telescopes (RTT150, T100, T60) at the site with a limited time quota. We have observed 10 variable stars among GAIA sources discovered in the years 2014-2016 that may be candidate Cataclysmic Variables (CVs). Our TUG observations at this stage involve photometry and spectroscopy to aid the identification of these sources. The first preliminary result of our observations of Gaia14aat among them showed a dwarf nova outburst with an amplitude of 2.69 mag. We aim to construct a GAIA astrophysics group to study CVs along with supported studies using the SRG (Spectrum Roentgen Gamma astrophysical observatory) after the year of 2016. These observations will basically involve spectroscopy, narrow-band CCD imaging and photometry using several filters to aid the identification of these sources. RTT150 observations with very narrow filters (like H-alpha, SII, OIII with band width of range of 2 to 5 nm) will reveal whether shell around the SRG sources to aid identification novae among them.
Models for various aspects of dwarf novae and nova-like stars
NASA Technical Reports Server (NTRS)
Ladous, Constanze
1993-01-01
The first attempts to explain the nature of dwarf novae were based on the assumption of single-star phenomena, in which emission lines were assumed to be caused by circumstellar gas shells. The outburst behavior was tentatively ascribed to the kind of (also not understood) mechanism leading to nova outbursts. The realization that some, and possibly all, dwarf novae and nova-like stars (and novae) are binaries eventually led to models which bore more and more similarities to the modern interpretation on the basis of the Roche model. Not all cataclysmic variables are known binaries. In fact, with respect to the entire number of known objects, the proven binaries are still the minority, but all the brightest variables are in fact known to binaries. Not a single system is known which exhibits the usual characteristics of a cataclysmic variable and at the same time can be declared with certainty to be a single star. Two systems are known, the dwarf nova EY Cyg and the recurrent nova V1017 Sgr, in which, in spite of intensive search, no radial velocity variations have been found; but they still exhibit composite spectra consisting of a bright continuum, an emission spectrum, and a cool absorption spectrum. If the Roche model is correct, it is to be expected that a small percentage of objects is viewed pole-on, so orbital motions do not make themselves felt as Doppler shifts of spectral lines. So even these two systems support the hypothesis that all cataclysmic variables (with the possible exception of symbiotic stars) are binaries. In cataclysmic variables, it seems that the brightness changes observed in dwarf novae and nova-like stars in the optical and the UV are due directly to changes in the accretion disks. The study and understanding of accretion disks in these systems can bear potentially valuable consequences for many other fields in astronomy. The observed spectra of dwarf novae and nova-like stars comprise a fairly large range: pure emission spectra, pure absorption spectra, a mixture of both, asymmetric line profiles, very different slopes of the continuous flux distribution -- and one single system may exhibit all of these features at different times. Agreement and disagreement between computed and observed spectra should show whether or not the Roche model is applicable and where it probably will have to be modified and improved. Except for their outburst behavior and its immediate consequences, novae, dwarf novae, and nova-like stars cannot be physically distinguished from each other.
Comparison of methods of alert acknowledgement by critical care clinicians in the ICU setting
Harrison, Andrew M.; Thongprayoon, Charat; Aakre, Christopher A.; Jeng, Jack Y.; Dziadzko, Mikhail A.; Gajic, Ognjen; Pickering, Brian W.
2017-01-01
Background Electronic Health Record (EHR)-based sepsis alert systems have failed to demonstrate improvements in clinically meaningful endpoints. However, the effect of implementation barriers on the success of new sepsis alert systems is rarely explored. Objective To test the hypothesis time to severe sepsis alert acknowledgement by critical care clinicians in the ICU setting would be reduced using an EHR-based alert acknowledgement system compared to a text paging-based system. Study Design In one arm of this simulation study, real alerts for patients in the medical ICU were delivered to critical care clinicians through the EHR. In the other arm, simulated alerts were delivered through text paging. The primary outcome was time to alert acknowledgement. The secondary outcomes were a structured, mixed quantitative/qualitative survey and informal group interview. Results The alert acknowledgement rate from the severe sepsis alert system was 3% (N = 148) and 51% (N = 156) from simulated severe sepsis alerts through traditional text paging. Time to alert acknowledgement from the severe sepsis alert system was median 274 min (N = 5) and median 2 min (N = 80) from text paging. The response rate from the EHR-based alert system was insufficient to compare primary measures. However, secondary measures revealed important barriers. Conclusion Alert fatigue, interruption, human error, and information overload are barriers to alert and simulation studies in the ICU setting. PMID:28316887
Comparison of methods of alert acknowledgement by critical care clinicians in the ICU setting.
Harrison, Andrew M; Thongprayoon, Charat; Aakre, Christopher A; Jeng, Jack Y; Dziadzko, Mikhail A; Gajic, Ognjen; Pickering, Brian W; Herasevich, Vitaly
2017-01-01
Electronic Health Record (EHR)-based sepsis alert systems have failed to demonstrate improvements in clinically meaningful endpoints. However, the effect of implementation barriers on the success of new sepsis alert systems is rarely explored. To test the hypothesis time to severe sepsis alert acknowledgement by critical care clinicians in the ICU setting would be reduced using an EHR-based alert acknowledgement system compared to a text paging-based system. In one arm of this simulation study, real alerts for patients in the medical ICU were delivered to critical care clinicians through the EHR. In the other arm, simulated alerts were delivered through text paging. The primary outcome was time to alert acknowledgement. The secondary outcomes were a structured, mixed quantitative/qualitative survey and informal group interview. The alert acknowledgement rate from the severe sepsis alert system was 3% ( N = 148) and 51% ( N = 156) from simulated severe sepsis alerts through traditional text paging. Time to alert acknowledgement from the severe sepsis alert system was median 274 min ( N = 5) and median 2 min ( N = 80) from text paging. The response rate from the EHR-based alert system was insufficient to compare primary measures. However, secondary measures revealed important barriers. Alert fatigue, interruption, human error, and information overload are barriers to alert and simulation studies in the ICU setting.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shafter, A. W.; Henze, M.; Rector, T. A.
2015-02-01
The reported positions of 964 suspected nova eruptions in M31 recorded through the end of calendar year 2013 have been compared in order to identify recurrent nova (RN) candidates. To pass the initial screen and qualify as a RN candidate, two or more eruptions were required to be coincident within 0.′1, although this criterion was relaxed to 0.′15 for novae discovered on early photographic patrols. A total of 118 eruptions from 51 potential RN systems satisfied the screening criterion. To determine what fraction of these novae are indeed recurrent, the original plates and published images of the relevant eruptions havemore » been carefully compared. This procedure has resulted in the elimination of 27 of the 51 progenitor candidates (61 eruptions) from further consideration as RNe, with another 8 systems (17 eruptions) deemed unlikely to be recurrent. Of the remaining 16 systems, 12 candidates (32 eruptions) were judged to be RNe, with an additional 4 systems (8 eruptions) being possibly recurrent. It is estimated that ∼4% of the nova eruptions seen in M31 over the past century are associated with RNe. A Monte Carlo analysis shows that the discovery efficiency for RNe may be as low as 10% that for novae in general, suggesting that as many as one in three nova eruptions observed in M31 arise from progenitor systems having recurrence times ≲100 yr. For plausible system parameters, it appears unlikely that RNe can provide a significant channel for the production of Type Ia supernovae.« less
47 CFR 80.277 - Ship Security Alert System (SSAS).
Code of Federal Regulations, 2010 CFR
2010-10-01
... 47 Telecommunication 5 2010-10-01 2010-10-01 false Ship Security Alert System (SSAS). 80.277... Security Alert System (SSAS). (a) Vessels equipped with a Ship Security Alert System pursuant to the Safety..., “RTCM Standard 11020.0—Ship Security Alert Systems (SSAS) using the Cospas-Sarsat System,” Version 1.0...
The NAS Alert System: A look at the first eight years
Fuller, Pamela L.; Neilson, Matt; Huge, Dane H.
2013-01-01
The U.S. Geological Survey's Nonindigenous Aquatic Species (NAS) database program (http://nas.er.usgs.gov) tracks the distribution of introduced aquatic organisms across the United States. Awareness of, and timely response to, novel species introductions by those involved in nonindigenous aquatic species management and research requires a framework for rapid dissemination of occurrence data as it is incorporated into the NAS database. In May 2004, the NAS program developed an alert system to notify registered users of new introductions as part of a national early detection/rapid response system. This article summarizes information on system users and dispatched alerts from the system's inception through the end of 2011. The NAS alert system has registered over 1,700 users, with approximately 800 current subscribers. A total of 1,189 alerts had been transmitted through 2011. More alerts were sent for Florida (134 alerts) than for any other state. Fishes comprise the largest taxonomic group of alerts (440), with mollusks, plants, and crustaceans each containing over 100 alerts. Most alerts were for organisms that were intentionally released (414 alerts), with shipping, escape from captivity, and hitchhiking also representing major vectors. To explore the archive of sent alerts and to register, the search and signup page for the alert system can be found online at http://nas.er.usgs.gov/AlertSystem/default.aspx.
Ultraviolet spectroscopy of old novae and symbiotic stars
NASA Technical Reports Server (NTRS)
Lambert, D. L.; Slovak, M. H.; Shields, G. A.; Ferland, G. J.
1981-01-01
The IUE spectra are presented for two old novae and for two of the symbiotic variables. Prominent emission line spectra are revealed as a continuum whose appearance is effected by the system inclination. These data provide evidence for hot companions in the symbiotic stars, making plausible the binary model for these peculiar stars. Recent IUE spectra of dwarf novae provide additional support for the existence of optically thick accretion disks in active binary systems. The ultraviolet data of the eclipsing dwarf novae EX Hya and BV Cen appear flatter than for the noneclipsing systems, an effect which could be ascribed to the system inclination.
Binary Orbits as the Driver of Gamma-Ray Emission and Mass Ejection in Classical Novae
NASA Technical Reports Server (NTRS)
Chomiuk, Laura; Linford, Justin D.; Yang, Jun; O'Brien, T. J.; Paragi, Zsolt; Mioduszewski, Amy J.; Beswick, R. J.; Cheung, C. C.; Mukai, Koji; Nelson, Thomas
2014-01-01
Classical novae are the most common astrophysical thermonuclear explosions, occurring on the surfaces of white dwarf stars accreting gas from companions in binary star systems. Novae typically expel about 10 (sup -4) solar masses of material at velocities exceeding 1,000 kilometers per second.However, the mechanism of mass ejection in novae is poorly understood, and could be dominated by the impulsive flash of thermonuclear energy, prolonged optically thick winds or binary interaction with the nova envelope. Classical novae are now routinely detected at giga-electronvolt gamma-ray wavelengths, suggesting that relativistic particles are accelerated by strong shocks in the ejecta. Here we report high-resolution radio imaging of the gamma-ray-emitting nova V959 Mon. We find that its ejecta were shaped by the motion of the binary system: some gas was expelled rapidly along the poles as a wind from the white dwarf, while denser material drifted out along the equatorial plane, propelled by orbital motion..At the interface between the equatorial and polar regions, we observe synchrotron emission indicative of shocks and relativistic particle acceleration, thereby pinpointing the location of gamma-ray production. Binary shaping of the nova ejecta and associated internal shocks are expected to be widespread among novae, explaining why many novae are gamma-ray emitters.
Evaluating Alerting and Guidance Performance of a UAS Detect-And-Avoid System
NASA Technical Reports Server (NTRS)
Lee, Seung Man; Park, Chunki; Thipphavong, David P.; Isaacson, Douglas R.; Santiago, Confesor
2016-01-01
A key challenge to the routine, safe operation of unmanned aircraft systems (UAS) is the development of detect-and-avoid (DAA) systems to aid the UAS pilot in remaining "well clear" of nearby aircraft. The goal of this study is to investigate the effect of alerting criteria and pilot response delay on the safety and performance of UAS DAA systems in the context of routine civil UAS operations in the National Airspace System (NAS). A NAS-wide fast-time simulation study was conducted to assess UAS DAA system performance with a large number of encounters and a broad set of DAA alerting and guidance system parameters. Three attributes of the DAA system were controlled as independent variables in the study to conduct trade-off analyses: UAS trajectory prediction method (dead-reckoning vs. intent-based), alerting time threshold (related to predicted time to LoWC), and alerting distance threshold (related to predicted Horizontal Miss Distance, or HMD). A set of metrics, such as the percentage of true positive, false positive, and missed alerts, based on signal detection theory and analysis methods utilizing the Receiver Operating Characteristic (ROC) curves were proposed to evaluate the safety and performance of DAA alerting and guidance systems and aid development of DAA system performance standards. The effect of pilot response delay on the performance of DAA systems was evaluated using a DAA alerting and guidance model and a pilot model developed to support this study. A total of 18 fast-time simulations were conducted with nine different DAA alerting threshold settings and two different trajectory prediction methods, using recorded radar traffic from current Visual Flight Rules (VFR) operations, and supplemented with DAA-equipped UAS traffic based on mission profiles modeling future UAS operations. Results indicate DAA alerting distance threshold has a greater effect on DAA system performance than DAA alerting time threshold or ownship trajectory prediction method. Further analysis on the alert lead time (time in advance of predicted loss of well clear at which a DAA alert is first issued) indicated a strong positive correlation between alert lead time and DAA system performance (i.e. the ability of the UAS pilot to maneuver the unmanned aircraft to remain well clear). While bigger distance thresholds had beneficial effects on alert lead time and missed alert rate, it also generated a higher rate of false alerts. In the design and development of DAA alerting and guidance systems, therefore, the positive and negative effects of false alerts and missed alerts should be carefully considered to achieve acceptable alerting system performance by balancing false and missed alerts. The results and methodology presented in this study are expected to help stakeholders, policymakers and standards committees define the appropriate setting of DAA system parameter thresholds for UAS that ensure safety while minimizing operational impacts to the NAS and equipage requirements for its users before DAA operational performance standards can be finalized.
A framework for evaluating the appropriateness of clinical decision support alerts and responses
Waitman, Lemuel R; Lewis, Julia B; Wright, Julie A; Choma, David P; Miller, Randolph A; Peterson, Josh F
2011-01-01
Objective Alerting systems, a type of clinical decision support, are increasingly prevalent in healthcare, yet few studies have concurrently measured the appropriateness of alerts with provider responses to alerts. Recent reports of suboptimal alert system design and implementation highlight the need for better evaluation to inform future designs. The authors present a comprehensive framework for evaluating the clinical appropriateness of synchronous, interruptive medication safety alerts. Methods Through literature review and iterative testing, metrics were developed that describe successes, justifiable overrides, provider non-adherence, and unintended adverse consequences of clinical decision support alerts. The framework was validated by applying it to a medication alerting system for patients with acute kidney injury (AKI). Results Through expert review, the framework assesses each alert episode for appropriateness of the alert display and the necessity and urgency of a clinical response. Primary outcomes of the framework include the false positive alert rate, alert override rate, provider non-adherence rate, and rate of provider response appropriateness. Application of the framework to evaluate an existing AKI medication alerting system provided a more complete understanding of the process outcomes measured in the AKI medication alerting system. The authors confirmed that previous alerts and provider responses were most often appropriate. Conclusion The new evaluation model offers a potentially effective method for assessing the clinical appropriateness of synchronous interruptive medication alerts prior to evaluating patient outcomes in a comparative trial. More work can determine the generalizability of the framework for use in other settings and other alert types. PMID:21849334
The Potential of NovaNET Communications for Education and Instruction.
ERIC Educational Resources Information Center
Steinberg, Esther R.
Intended to suggest ways of implementing the potential of NovaNet beyond its current applications, this report begins with an overview of current educational applications of telecommunications systems. It is noted that NovaNET is not only a successful computer system for presenting instructional courseware, but that it also supports…
76 FR 80780 - Review of the Emergency Alert System
Federal Register 2010, 2011, 2012, 2013, 2014
2011-12-27
... Emergency Alert System AGENCY: Federal Communications Commission. ACTION: Final rule. SUMMARY: In this document, the Commission amends its rules governing the Emergency Alert System (EAS) rules to extend the deadline for EAS Participants to be able to receive Common Alerting Protocol (CAP)- formatted EAS alerts to...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-10-07
... Communication & Surveillance Systems (ACSS) Traffic Alert and Collision Avoidance System (TCAS) Units AGENCY... certain Aviation Communication & Surveillance Systems (ACSS) traffic alert and collision avoidance system...) traffic alert and collision avoidance system (TCAS) units with part numbers identified in ACSS Technical...
Naval Observatory Vector Astrometry Software (NOVAS) Version 3.1:Fortran, C, and Python Editions
NASA Astrophysics Data System (ADS)
Kaplan, G. H.; Bangert, J. A.; Barron, E. G.; Bartlett, J. L.; Puatua, W.; Harris, W.; Barrett, P.
2012-08-01
The Naval Observatory Vector Astrometry Software (NOVAS) is a source - code library that provides common astrometric quantities and transformations to high precision. The library can supply, in one or two subroutine or function calls, the instantaneous celestial position of any star or planet in a variety of coordinate systems. NOVAS also provides access to all of the building blocks that go into such computations. NOVAS is used for a wide variety of applications, including the U.S. portions of The Astronomical Almanac and a number of telescope control systems. NOVAS uses IAU recommended models for Earth orientation, including the IAU 2006 precession theory, the IAU 2000A and 2000B nutation series, and diurnal rotation based on the celestial and terrestrial intermediate origins. Equinox - based quantities, such as sidereal time, are also supported. NOVAS Earth orientation calculations match those from SOFA at the sub - microarcsecond level for comparable transformations. NOVAS algorithms for aberration an d gravitational light deflection are equivalent, at the microarcsecond level, to those inherent in the current consensus VLBI delay algorithm. NOVAS can be easily connected to the JPL planetary/lunar ephemerides (e.g., DE405), and connections to IMCCE and IAA planetary ephemerides are planned. NOVAS Version 3.1 introduces a Python edition alongside the Fortran and C editions. The Python edition uses the computational code from the C edition and currently mimics the function calls of the C edition. Future versions will expand the functionality of the Python edition to exploit the object - oriented features of Python. In the Version 3.1 C edition, the ephemeris - access functions have been revised for use on 64 - bit systems and for improved performance in general. NOVAS source code, auxiliary files, and documentation are available from the USNO website (http://aa.usno.navy.mil/software/novas/novas_info.php).
Pilot Non-Conformance to Alerting System Commands During Closely Spaced Parallel Approaches
NASA Technical Reports Server (NTRS)
Pritchett, Amy Ruth; Hansman, R. John; Corker, Kevin (Technical Monitor)
1997-01-01
Cockpit alerting systems monitor potentially hazardous situations, both inside and outside the aircraft. When a hazard is projected to occur, the alerting system displays alerts and/or command decisions to the pilot. However, pilots have been observed to not conform to alerting system commands by delaying their response or by not following the automatic commands exactly. This non-conformance to the automatic alerting system can reduce its benefit. Therefore, a need exists to understand the causes and effects of pilot non-conformance in order to develop automatic alerting systems whose commands the pilots are more likely to follow. These considerations were examined through flight simulator evaluations of the collision avoidance task during closely spaced parallel approaches. This task provided a useful case-study because the effects of non-conformance can be significant, given the time-critical nature of the task. A preliminary evaluation of alerting systems identified non-conformance in over 40% of the cases and a corresponding drop in collision avoidance performance. A follow-on experiment found subjects' alerting and maneuver selection criteria were consistent with different strategies than those used by automatic systems, indicating the pilot may potentially disagree with the alerting system if the pilot attempts to verify automatic alerts and commanded avoidance maneuvers. A final experiment found supporting automatic alerts with the explicit display of its underlying criteria resulted in more consistent subject reactions. In light of these experimental results, a general discussion of pilot non-conformance is provided. Contributing factors in pilot non-conformance include a lack of confidence in the automatic system and mismatches between the alerting system's commands and the pilots' own decisions based on the information available to them. The effects of non-conformance on system performance are discussed. Possible methods of reconciling mismatches are given, and design considerations for alerting systems which alleviate the problem of non-conformance are provided.
Analysis of Alerting System Failures in Commercial Aviation Accidents
NASA Technical Reports Server (NTRS)
Mumaw, Randall J.
2017-01-01
The role of an alerting system is to make the system operator (e.g., pilot) aware of an impending hazard or unsafe state so the hazard can be avoided or managed successfully. A review of 46 commercial aviation accidents (between 1998 and 2014) revealed that, in the vast majority of events, either the hazard was not alerted or relevant hazard alerting occurred but failed to aid the flight crew sufficiently. For this set of events, alerting system failures were placed in one of five phases: Detection, Understanding, Action Selection, Prioritization, and Execution. This study also reviewed the evolution of alerting system schemes in commercial aviation, which revealed naive assumptions about pilot reliability in monitoring flight path parameters; specifically, pilot monitoring was assumed to be more effective than it actually is. Examples are provided of the types of alerting system failures that have occurred, and recommendations are provided for alerting system improvements.
On the Accretion Rates of SW Sextantis Nova-like Variables
NASA Astrophysics Data System (ADS)
Ballouz, Ronald-Louis; Sion, Edward M.
2009-06-01
We present accretion rates for selected samples of nova-like variables having IUE archival spectra and distances uniformly determined using an infrared method by Knigge. A comparison with accretion rates derived independently with a multiparametric optimization modeling approach by Puebla et al. is carried out. The accretion rates of SW Sextantis nova-like systems are compared with the accretion rates of non-SW Sextantis systems in the Puebla et al. sample and in our sample, which was selected in the orbital period range of three to four and a half hours, with all systems having distances using the method of Knigge. Based upon the two independent modeling approaches, we find no significant difference between the accretion rates of SW Sextantis systems and non-SW Sextantis nova-like systems insofar as optically thick disk models are appropriate. We find little evidence to suggest that the SW Sex stars have higher accretion rates than other nova-like cataclysmic variables (CVs) above the period gap within the same range of orbital periods.
Analysis of UAS DAA Alerting in Fast-Time Simulations without DAA Mitigation
NASA Technical Reports Server (NTRS)
Thipphavong, David P.; Santiago, Confesor; Isaacson, Douglas R.; Lee, Seung Man; Park, Chunki; Refai, Mohamad Said; Snow, James
2015-01-01
Realization of the expected proliferation of Unmanned Aircraft System (UAS) operations in the National Airspace System (NAS) depends on the development and validation of performance standards for UAS Detect and Avoid (DAA) Systems. The RTCA Special Committee 228 is charged with leading the development of draft Minimum Operational Performance Standards (MOPS) for UAS DAA Systems. NASA, as a participating member of RTCA SC-228 is committed to supporting the development and validation of draft requirements for DAA alerting system performance. A recent study conducted using NASA's ACES (Airspace Concept Evaluation System) simulation capability begins to address questions surrounding the development of draft MOPS for DAA alerting systems. ACES simulations were conducted to study the performance of alerting systems proposed by the SC-228 DAA Alerting sub-group. Analysis included but was not limited to: 1) correct alert (and timeliness), 2) false alert (and severity and duration), 3) missed alert, and 4) probability of an alert type at the time of loss of well clear. The performance of DAA alerting systems when using intent vs. dead-reckoning for UAS ownship trajectories was also compared. The results will be used by SC-228 to inform decisions about the surveillance standards of UAS DAA systems and future requirements development and validation efforts.
Polarimetry and spectroscopy of the "oxygen flaring" DQ Herculis-like nova: V5668 Sagittarii (2015)
NASA Astrophysics Data System (ADS)
Harvey, E. J.; Redman, M. P.; Darnley, M. J.; Williams, S. C.; Berdyugin, A.; Piirola, V. E.; Fitzgerald, K. P.; O'Connor, E. G. P.
2018-03-01
Context. Classical novae are eruptions on the surface of a white dwarf in a binary system. The material ejected from the white dwarf surface generally forms an axisymmetric shell of gas and dust around the system. The three-dimensional structure of these shells is difficult to untangle when viewed on the plane of the sky. In this work a geometrical model is developed to explain new observations of the 2015 nova V5668 Sagittarii. Aim. We aim to better understand the early evolution of classical nova shells in the context of the relationship between polarisation, photometry, and spectroscopy in the optical regime. To understand the ionisation structure in terms of the nova shell morphology and estimate the emission distribution directly following the light curve's dust-dip. Methods: High-cadence optical polarimetry and spectroscopy observations of a nova are presented. The ejecta is modelled in terms of morpho-kinematics and photoionisation structure. Results: Initially observational results are presented, including broadband polarimetry and spectroscopy of V5668 Sgr nova during eruption. Variability over these observations provides clues towards the evolving structure of the nova shell. The position angle of the shell is derived from polarimetry, which is attributed to scattering from small dust grains. Shocks in the nova outflow are suggested in the photometry and the effect of these on the nova shell are illustrated with various physical diagnostics. Changes in density and temperature as the super soft source phase of the nova began are discussed. Gas densities are found to be of the order of 109 cm-3 for the nova in its auroral phase. The blackbody temperature of the central stellar system is estimated to be around 2.2 × 105 K at times coincident with the super soft source turn-on. It was found that the blend around 4640 Å commonly called "nitrogen flaring" is more naturally explained as flaring of the O II multiplet (V1) from 4638-4696 Å, i.e. "oxygen flaring". Conclusions: V5668 Sgr (2015) was a remarkable nova of the DQ Her class. Changes in absolute polarimetric and spectroscopic multi-epoch observations lead to interpretations of physical characteristics of the nova's evolving outflow. The high densities that were found early-on combined with knowledge of the system's behaviour at other wavelengths and polarimetric measurements strongly suggest that the visual "cusps" are due to radiative shocks between fast and slow ejecta that destroy and create dust seed nuclei cyclically.
77 FR 41331 - Commercial Mobile Alert System
Federal Register 2010, 2011, 2012, 2013, 2014
2012-07-13
... Mobile Alert System AGENCY: Federal Communications Commission. ACTION: Final rule; announcement of... with the Commission's Commercial Mobile Alert System (CMS), Second Report and Order (``CMAS Second... Alert System rules contained in the Commission's Second Report and Order, FCC 08- 164, published at 73...
Identification of Recurrent Novae in M31
NASA Astrophysics Data System (ADS)
Shafter, Allen W.; Rector, T. A.; Schweizer, F.; Bryan, J.
2014-01-01
Over roughly the past century a total of more than 900 optical transient events have been recorded in M31, the vast majority of which are believed to represent eruptions of classical novae. The impressive dataset of nova positions put together by Pietsch (http://www.mpe.mpg.de m31novae/opt/m31/) provides the opportunity to search for multiple nova outbursts from the same progenitor system, and thus to characterize the population of recurrent novae (RNe) in M31. In order to identify RNe candidates, we have searched for spatial near coincidences among the 945 recorded novae given in the Pietsch catalog through the end of August 2013. Given that the positions of many of the early novae are quite uncertain, we have set our initial screen to include nova pairs with nominal separations less than or equal to 6 arcsec. We have identified a total of 102 novae that pass this coarse screen. Of these, 78 novae form 39 pairs, 15 form five triples, four novae are part of a quad, and five novae form a quint. As demonstrated by Shafter, Rice and Daub (2009, presented at the "Wild Stars in the Old West II" conference, mintaka.sdsu.edu/faculty/shafter/extragalactic_novae/RNePoster4.pdf), the majority of the 102 novae surviving our initial screen are expected to be associated with chance positional near coincidences (especially near the nucleus), and are not RNe. To decide which candidates are indeed RNe, we have undertaken a study to locate the original discovery plates, CCD images or published finding charts, and to perform the necessary astrometry to identify which of our candidate RNe are chance positional coincidences, and which are RNe. For each candidate, we estimate the probability that the object is a chance positional coincidence as in Shafter et al. (2009). To date, we have been successful in identifying finding charts or original images for most of the candidates, and have found a total of 23 nova outbursts in M31 associated with 10 systems that are almost certainly RNe.
Cuéllar Monreal, Mª Jesús; Reig Aguado, Jorge; Font Noguera, Isabel; Poveda Andrés, José Luis
2017-01-01
To reduce the alert fatigue in our Assisted Electronic Prescribing System (AEPS), through the Lean Six Sigma (LSS) methodology. An observational (transversal) and retrospective study, in a general hospital with 850 beds and AEPS. The LSS methodology was followed in order to evaluate the alert fatigue situation in the AEPS system, to implement improvements, and to assess outcomes. The alerts generated during two trimesters studied (before and after the intervention) were analyzed. In order to measure the qualitative indicators, the most frequent alert types were analyzed, as well as the molecules responsible for over 50% of each type of alert. The action by the prescriber was analyzed in a sample of 496 prescriptions that generated such alerts. For each type of alert and molecule, there was a prioritization of the improvements to be implemented according to the alert generated and its quality. A second survey evaluated the pharmacist action for the alerts most highly valued by physicians. The problem, the objective, the work team and the project schedule were defined. A survey was designed in order to understand the opinion of the client about the alert system in the program. Based on the surveys collected (n = 136), the critical characteristics and the quanti/qualitative indicators were defined. Sixty (60) fields in the alert system were modified, corresponding to 32 molecules, and this led to a 28% reduction in the total number of alerts. Regarding quality indicators, false po sitive results were reduced by 25% (p < 0.05), 100% of those alerts ignored with justification were sustained, and there were no significant differences in user adherence to the system. The project improvements and outcomes were reviewed by the work team. LSS methodology has demonstrated being a valid tool for the quantitative and qualitative improvement of the alert system in an Assisted Electronic Prescription Program, thus reducing alert fatigue. Copyright AULA MEDICA EDICIONES 2014. Published by AULA MEDICA. All rights reserved.
77 FR 33661 - Review of the Emergency Alert System
Federal Register 2010, 2011, 2012, 2013, 2014
2012-06-07
... Emergency Alert System AGENCY: Federal Communications Commission. ACTION: Final rule; announcement of... Commission's Review of the Emergency Alert System, Fifth Report and Order (Order). This document is... Expiration Date: November 30, 2012. Title: Part 11--Emergency Alert System, Fifth Report and Order, FCC 12-7...
Optimizing drug-dose alerts using commercial software throughout an integrated health care system.
Saiyed, Salim M; Greco, Peter J; Fernandes, Glenn; Kaelber, David C
2017-11-01
All default electronic health record and drug reference database vendor drug-dose alerting recommendations (single dose, daily dose, dose frequency, and dose duration) were silently turned on in inpatient, outpatient, and emergency department areas for pediatric-only and nonpediatric-only populations. Drug-dose alerts were evaluated during a 3-month period. Drug-dose alerts fired on 12% of orders (104 098/834 911). System-level and drug-specific strategies to decrease drug-dose alerts were analyzed. System-level strategies included: (1) turning off all minimum drug-dosing alerts, (2) turning off all incomplete information drug-dosing alerts, (3) increasing the maximum single-dose drug-dose alert threshold to 125%, (4) increasing the daily dose maximum drug-dose alert threshold to 125%, and (5) increasing the dose frequency drug-dose alert threshold to more than 2 doses per day above initial threshold. Drug-specific strategies included changing drug-specific maximum single and maximum daily drug-dose alerting parameters for the top 22 drug categories by alert frequency. System-level approaches decreased alerting to 5% (46 988/834 911) and drug-specific approaches decreased alerts to 3% (25 455/834 911). Drug-dose alerts varied between care settings and patient populations. © The Author 2017. Published by Oxford University Press on behalf of the American Medical Informatics Association. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Kuperman, G. J.; Teich, J. M.; Bates, D. W.; Hiltz, F. L.; Hurley, J. M.; Lee, R. Y.; Paterno, M. D.
1996-01-01
We developed and evaluated a system to automatically identify serious clinical conditions in inpatients. The system notifies the patient's covering physician via his pager that an alert is present and offers potential therapies for the patient's condition (action items) at the time he views the alert information. Over a 6 month period, physicians responded to 1214 (70.2%) of 1730 alerts for which they were paged; they responded to 1002 (82.5% of the 1214) in less than 15 minutes. They said they would take action in 71.5% of the alerts, and they placed an order directly from the alert display screen in 39.4%. Further study is needed to determine if this alerting system improves processes or outcomes of care. PMID:8947756
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 1 2013-04-01 2013-04-01 false Alert system. 26.20 Section 26.20 Food and Drugs... PHARMACEUTICAL GOOD MANUFACTURING PRACTICE REPORTS, MEDICAL DEVICE QUALITY SYSTEM AUDIT REPORTS, AND CERTAIN... Provisions for Pharmaceutical Good Manufacturing Practices § 26.20 Alert system. (a) The details of an alert...
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 1 2012-04-01 2012-04-01 false Alert system. 26.20 Section 26.20 Food and Drugs... PHARMACEUTICAL GOOD MANUFACTURING PRACTICE REPORTS, MEDICAL DEVICE QUALITY SYSTEM AUDIT REPORTS, AND CERTAIN... Provisions for Pharmaceutical Good Manufacturing Practices § 26.20 Alert system. (a) The details of an alert...
Code of Federal Regulations, 2010 CFR
2010-04-01
... PHARMACEUTICAL GOOD MANUFACTURING PRACTICE REPORTS, MEDICAL DEVICE QUALITY SYSTEM AUDIT REPORTS, AND CERTAIN... 21 Food and Drugs 1 2010-04-01 2010-04-01 false Alert system. 26.20 Section 26.20 Food and Drugs... Provisions for Pharmaceutical Good Manufacturing Practices § 26.20 Alert system. (a) The details of an alert...
47 CFR 80.277 - Ship Security Alert System (SSAS).
Code of Federal Regulations, 2011 CFR
2011-10-01
... 47 Telecommunication 5 2011-10-01 2011-10-01 false Ship Security Alert System (SSAS). 80.277... SERVICES STATIONS IN THE MARITIME SERVICES Equipment Authorization for Compulsory Ships § 80.277 Ship Security Alert System (SSAS). (a) Vessels equipped with a Ship Security Alert System pursuant to the Safety...
47 CFR 80.277 - Ship Security Alert System (SSAS).
Code of Federal Regulations, 2014 CFR
2014-10-01
... 47 Telecommunication 5 2014-10-01 2014-10-01 false Ship Security Alert System (SSAS). 80.277... SERVICES STATIONS IN THE MARITIME SERVICES Equipment Authorization for Compulsory Ships § 80.277 Ship Security Alert System (SSAS). (a) Vessels equipped with a Ship Security Alert System pursuant to the Safety...
47 CFR 80.277 - Ship Security Alert System (SSAS).
Code of Federal Regulations, 2012 CFR
2012-10-01
... 47 Telecommunication 5 2012-10-01 2012-10-01 false Ship Security Alert System (SSAS). 80.277... SERVICES STATIONS IN THE MARITIME SERVICES Equipment Authorization for Compulsory Ships § 80.277 Ship Security Alert System (SSAS). (a) Vessels equipped with a Ship Security Alert System pursuant to the Safety...
47 CFR 80.277 - Ship Security Alert System (SSAS).
Code of Federal Regulations, 2013 CFR
2013-10-01
... 47 Telecommunication 5 2013-10-01 2013-10-01 false Ship Security Alert System (SSAS). 80.277... SERVICES STATIONS IN THE MARITIME SERVICES Equipment Authorization for Compulsory Ships § 80.277 Ship Security Alert System (SSAS). (a) Vessels equipped with a Ship Security Alert System pursuant to the Safety...
On the implications of the period distributions of subclasses of cataclysmic variables
NASA Astrophysics Data System (ADS)
Verbunt, Frank
1997-09-01
The period distributions of dwarf novae and nova-like variables above the period gap are different if the VY Scl systems are classed with the nova-like variables, but the same when the VY Scl phenomenon is classed with the dwarf nova outbursts. For the remaining nova-like variables, the period gap is no longer significant. Classification of the VY Scl phenomenon with dwarf novae suggests that dwarf nova outbursts are caused by variation in mass transfer from the donor. Absence of the period gap obviates the need for models explaining it, and invalidates one piece of evidence for the importance of magnetic braking for the evolution of cataclysmic variables and of low-mass binaries in general.
Development and implementation of sepsis alert systems
Harrison, Andrew M.; Gajic, Ognjen; Pickering, Brian W.; Herasevich, Vitaly
2016-01-01
Synopsis/Summary Development and implementation of sepsis alert systems is challenging, particularly outside the monitored intensive care unit (ICU) setting. Important barriers to wider use of sepsis alerts include evolving clinical definitions of sepsis, information overload & alert fatigue, due to suboptimal alert performance. Outside the ICU, additional barriers include differences in health care delivery models, charting behaviors, and availability of electronic data. Currently available evidence does not support routine use of sepsis alert systems in clinical practice. However, continuous improvement in both the afferent (data availability and accuracy of detection algorithms) and efferent (evidence-based decision support and smoother integration into clinical workflow) limbs of sepsis alert systems will help translate theoretical advantages into measurable patient benefit. PMID:27229639
Wireless clinical alerts for physiologic, laboratory and medication data.
Shabot, M. M.; LoBue, M.; Chen, J.
2000-01-01
A fully interfaced clinical information system (CIS) contains physiologic, laboratory, blood gas, medication and other data that can be used as the information base for a comprehensive alerting system. Coupled with an event driven rules engine, a CIS can generate clinical alerts which may both prevent medical errors and assist caregivers in responding to critical events in a timely way. The authors have developed a clinical alerting system which delivers alerts and reminders to clinicians in real time via a alphanumeric display pagers. This paper will describe the system, the type and number of alerts generated, and the impact on clinical practice. A major issue remains in measuring the impact of wireless alerts on patient outcomes. PMID:11079992
Shah, Priya; Wyatt, Jeremy C; Makubate, Boikanyo; Cross, Frank W
2011-01-01
Objective Expert authorities recommend clinical decision support systems to reduce prescribing error rates, yet large numbers of insignificant on-screen alerts presented in modal dialog boxes persistently interrupt clinicians, limiting the effectiveness of these systems. This study compared the impact of modal and non-modal electronic (e-) prescribing alerts on prescribing error rates, to help inform the design of clinical decision support systems. Design A randomized study of 24 junior doctors each performing 30 simulated prescribing tasks in random order with a prototype e-prescribing system. Using a within-participant design, doctors were randomized to be shown one of three types of e-prescribing alert (modal, non-modal, no alert) during each prescribing task. Measurements The main outcome measure was prescribing error rate. Structured interviews were performed to elicit participants' preferences for the prescribing alerts and their views on clinical decision support systems. Results Participants exposed to modal alerts were 11.6 times less likely to make a prescribing error than those not shown an alert (OR 11.56, 95% CI 6.00 to 22.26). Those shown a non-modal alert were 3.2 times less likely to make a prescribing error (OR 3.18, 95% CI 1.91 to 5.30) than those not shown an alert. The error rate with non-modal alerts was 3.6 times higher than with modal alerts (95% CI 1.88 to 7.04). Conclusions Both kinds of e-prescribing alerts significantly reduced prescribing error rates, but modal alerts were over three times more effective than non-modal alerts. This study provides new evidence about the relative effects of modal and non-modal alerts on prescribing outcomes. PMID:21836158
Phansalkar, Shobha; Edworthy, Judy; Hellier, Elizabeth; Seger, Diane L; Schedlbauer, Angela; Avery, Anthony J; Bates, David W
2010-01-01
The objective of this review is to describe the implementation of human factors principles for the design of alerts in clinical information systems. First, we conduct a review of alarm systems to identify human factors principles that are employed in the design and implementation of alerts. Second, we review the medical informatics literature to provide examples of the implementation of human factors principles in current clinical information systems using alerts to provide medication decision support. Last, we suggest actionable recommendations for delivering effective clinical decision support using alerts. A review of studies from the medical informatics literature suggests that many basic human factors principles are not followed, possibly contributing to the lack of acceptance of alerts in clinical information systems. We evaluate the limitations of current alerting philosophies and provide recommendations for improving acceptance of alerts by incorporating human factors principles in their design.
NASA Technical Reports Server (NTRS)
Livio, Mario; Truran, James W.
1994-01-01
We reexamine the question of the frequency of occurrence of oxygen-neon-magnesium (ONeMg) degenerate dwarfs in classical nova systems, in light of recent observations which have been interpreted as suggesting that 'neon novae' can be associated with relatively low mass white dwarfs. Determinations of heavy-element concentrations in nova ejecta are reviewed, and possible interpretations of their origin are examined. We conclude that, of the 18 classical novae for which detailed abundance analyses are availble, only two (or possibly three) seem unambiguously to demand the presence of an underlying ONeMg white dwarf: V693 CrA 1981, V1370 Aql 1982, and possibly QU Vul 1984. Three other novae which exhibit significant neon enrichments, relative to their total heavy-element concentrations, are RR Pic 1925, V977, Sco 1989, and LMC 1990 No. 1. This result is entirely consistent with present frequency estimates, and our interpretation of the lower levels of enrichment in other systems explains, in a natural way, the existence of relatively low mass white dwarfs in some of the 'neon' novae.
Recent Results on SNRs and PWNe from the Fermi Large Area Telescope
NASA Technical Reports Server (NTRS)
Hays, Elizabeth
2010-01-01
a) Symbiotic Binary System: White dwarf + red giant system. b) Nova: White dwarf builds up mass envelope to the point of thermonuclear fusion. c) Dramatic increase in visual magnitude. d) Recurrent Nova? e) Hints but no strong confirmation of previous nova f) Pre-nova activity: 1) White dwarf shows ongoing variability at level of several in magnitude. 2) V407 Cyg companion is a Mira star showing variability at level of several in magnitude. g) Origin of the gamma rays? 1) Strong shock propagating into dense medium around giant star land stellar wind. 2) Pion decay or electron processes?
Adoption of medication alert systems in hospital outpatient departments in Taiwan.
Kuo, Yu-Chun; Cheng, Shou-Hsia
2017-06-01
The adoption of medication alert systems in the health care sector varies among regions. In Taiwan, the health authority introduced policies in 2005 to encourage the adoption of medication alert systems in hospitals. This study aimed to understand the adoption of medication alert systems in the outpatient departments of hospitals in Taiwan using a nationwide survey. A questionnaire was developed and mailed to 380 accredited general hospitals in Taiwan in 2013. The information collected from the questionnaire concerning the outpatient department included (1) the time of adoption of a medication alert system; (2) the operation of individual alert functions: availability, management, and stability; and (3) hospital characteristics: accreditation level, teaching status, ownership, and number of beds. A total of 216 hospitals completed and returned the questionnaire, corresponding to a response rate of 56.8%. The adoption rate of medication alert systems in hospital outpatient departments increased from less than 10% in 1997-95.83% in 2012. Approximately two-thirds of the hospitals developed and maintained the alert systems independently or collaboratively with vendors. Teaching and large hospitals tended to develop more advanced alert functions such as drug-drug interaction functions. Improving the safety and quality of pharmaceutical services and meeting the policy requirements are reasons for hospitals to establish medication alert systems. The adoption rate of medication alert systems reached 95% in accredited general hospitals in Taiwan. Government policy and available health information professionals and vendors may somewhat contribute to the high adoption rate. Copyright © 2017 Elsevier B.V. All rights reserved.
NOVA Fall 2002 Teacher's Guide.
ERIC Educational Resources Information Center
Ransick, Kristina; Rosene, Dale; Sammons, James; Turck, Mary
This NOVA teacher's guide presents activities, information, and teaching ideas from the Public Broadcasting System's (PBS) NOVA television program series. Episodes include: (1) "Mysterious Life of Caves" which investigates the role microbes play in the creation of some limestone caves; (2) "Lost Roman Treasure" which follows…
New Nova Candidates from the RSBE M31 Nova Survey
NASA Astrophysics Data System (ADS)
Lauber, Stephanie; Rector, Travis A.; Shafter, Allen W.
2015-01-01
Since 1995 the Kitt Peak National Observatory WIYN 0.9-m telescope has been used to monitor M31 for novae as part of the Research-Based Science Education Project (RBSE). The resulting images, which typically cover approximately the inner 20 arc min of M31, are taken through a broad-band H-alpha filter to isolate the strong H-alpha emission lines characteristic of novae shortly after eruption.We are in the process of reanalyzing the entire RBSE data set covering the period between September 1995 and August 2014 in order to produce an up-to-date list of novae from this survey. Here, we present coordinates and H-alpha magnitudes for 4 new nova discoveries not previous reported. Among the new nova discoveries, one system appears spatially coincident with M31N 1988-09a, and is thus a recurrent nova candidate.
INITIATE: An Intelligent Adaptive Alert Environment.
Jafarpour, Borna; Abidi, Samina Raza; Ahmad, Ahmad Marwan; Abidi, Syed Sibte Raza
2015-01-01
Exposure to a large volume of alerts generated by medical Alert Generating Systems (AGS) such as drug-drug interaction softwares or clinical decision support systems over-whelms users and causes alert fatigue in them. Some of alert fatigue effects are ignoring crucial alerts and longer response times. A common approach to avoid alert fatigue is to devise mechanisms in AGS to stop them from generating alerts that are deemed irrelevant. In this paper, we present a novel framework called INITIATE: an INtellIgent adapTIve AlerT Environment to avoid alert fatigue by managing alerts generated by one or more AGS. We have identified and categories the lifecycle of different alerts and have developed alert management logic as per the alerts' lifecycle. Our framework incorporates an ontology that represents the alert management strategy and an alert management engine that executes this strategy. Our alert management framework offers the following features: (1) Adaptability based on users' feedback; (2) Personalization and aggregation of messages; and (3) Connection to Electronic Medical Records by implementing a HL7 Clinical Document Architecture parser.
47 CFR 10.300 - Alert aggregator. [Reserved
Code of Federal Regulations, 2010 CFR
2010-10-01
... 47 Telecommunication 1 2010-10-01 2010-10-01 false Alert aggregator. [Reserved] 10.300 Section 10.300 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM System Architecture § 10.300 Alert aggregator. [Reserved] ...
47 CFR 10.300 - Alert aggregator. [Reserved
Code of Federal Regulations, 2012 CFR
2012-10-01
... 47 Telecommunication 1 2012-10-01 2012-10-01 false Alert aggregator. [Reserved] 10.300 Section 10.300 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM System Architecture § 10.300 Alert aggregator. [Reserved] ...
47 CFR 10.300 - Alert aggregator. [Reserved
Code of Federal Regulations, 2011 CFR
2011-10-01
... 47 Telecommunication 1 2011-10-01 2011-10-01 false Alert aggregator. [Reserved] 10.300 Section 10.300 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM System Architecture § 10.300 Alert aggregator. [Reserved] ...
A Search for Novae in the M31 Globular Cluster System
NASA Astrophysics Data System (ADS)
Tomaney, Austin; Crotts, Arlin; Shafter, Allen
1992-12-01
Roughly 10% of all low mass X-ray binaries (LMXB's, neutron star - low mass sequence close binaries) are found in Galactic globular clusters (GC's) implying an enhancement per unit mass of roughly three orders of magnitude of these objects inside GC's compared with the field. Fabian, Pringle and Rees (1975) suggested that these lcose binary systems may be formed via tidal capture in the dense cluster cores. Similar arguments are likely to apply to nova systems which are cataclysmic variables (CV's) consisting of a close binary white dwarf - low mass main sequence star. Supporting arguments include the discovery over the past century of two novae in Galactic GC's, and the existence of low luminosity X-ray sources in GC's (Hertz and Grindlay 1983). In addition, surveys for novae in M31 indicate that the specfic density of novae in its bulge is an order of magnitude higher than its disk and it has been argued by Ciardullo et al. (1987) that novae in the bulge of M31 have been spawned inside GC's and subsequently ejected into the field. We present the results of a search (during 1988 and 1989) of over 200 M31 GC's using a fibre multi-object spectrograph to detect Hα emission, a signature of a potential nova eruptions. No eruptions were detected over an effective survey time of one year for the entire known M31 GC system. Although the lower mass of white dwarfs compared with neutron stars implies their effective capture cross section is smaller, we argue that since novae occur much more frequently on high mass white dwarfs this survey provides a sensitive test to the number of high mass CV's in GC's and their enhancement is unlikely to be as high as LMXB's.
Laying the foundation for a digital Nova Scotia
NASA Astrophysics Data System (ADS)
Bond, J.
2016-04-01
In 2013, the Province of Nova Scotia began an effort to modernize its coordinate referencing infrastructure known as the Nova Scotia Coordinate Referencing System (NSCRS). At that time, 8, active GPS stations were installed in southwest Nova Scotia to evaluate the technology's ability to address the Province's coordinate referencing needs. The success of the test phase helped build a business case to implement the technology across the entire Province. It is anticipated that by the end of 2015, 40 active GPS stations will be in place across Nova Scotia. This infrastructure, known as the Nova Scotia Active Control Stations (NSACS) network, will allow for instantaneous, centimetre level positioning across the Province. Originally designed to address the needs of the surveying community, the technology has also proven to have applications in mapping, machine automation, agriculture, navigation, emergency response, earthquake detection and other areas. In the foreseeable future, all spatial data sets captured in Nova Scotia will be either directly or indirectly derived from the NSACS network. The technology will promote high accuracy and homogenous spatial data sets across the Province. The technology behind the NSACS and the development of the system are described. Examples of how the technology is contributing to a digital Nova Scotia are presented. Future applications of the technology are also considered.
2016-03-11
Control and Prevention Evaluation of a National Call Center and a Local Alerts System for Detection of New Cases of Ebola Virus Disease — Guinea, 2014...principally through the use of a telephone alert system. Community members and health facilities report deaths and suspected Ebola cases to local alert ...sensitivity of the national call center with the local alerts system, the CDC country team performed probabilistic record linkage of the combined
NASA Technical Reports Server (NTRS)
1983-01-01
NASA research and design has significantly improved crew alert systems. The Engine Indication and Crew Alerting System (EICAS), developed by Psycho-Linguistic Research Associates, is technologically advanced and able to order alerts by priority. Ames has also developed computer controlled voice synthesizers for readouts during difficult landing approaches. This is available to airplane manufacturers.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-02-07
... Airworthiness Directives; Aviation Communication & Surveillance Systems (ACSS) Traffic Alert and Collision... Communication & Surveillance Systems (ACSS) traffic alert and collision avoidance system (TCAS) units with part...
Campmans, Zizi; van Rhijn, Arianne; Dull, René M; Santen-Reestman, Jacqueline; Taxis, Katja; Borgsteede, Sander D
2018-01-01
Drug confusion is thought to be the most common type of dispensing error. Several strategies can be implemented to reduce the risk of medication errors. One of these are alerts in the pharmacy information system. To evaluate the experiences of pharmacists and pharmacy technicians with alerts for drug name and strength confusion. In May 2017, a cross-sectional survey of pharmacists and pharmacy technicians was performed in community pharmacies in the Netherlands using an online questionnaire. Of the 269 respondents, 86% (n = 230) had noticed the alert for drug name confusion, and 26% (n = 67) for drug strength confusion. Of those 230, 9% (n = 20) had experienced that the alert had prevented dispensing the wrong drug. For drug strength confusion, this proportion was 12% (n = 8). Respondents preferred to have an alert for drug name and strength confusion in the pharmacy information system. 'Alert fatigue' was an important issue, so alerts should only be introduced for frequent confusions or confusions with serious consequences. Pharmacists and pharmacy technicians were positive about having alerts for drug confusions in their pharmacy information system and experienced that alerts contributed to the prevention of dispensing errors. To prevent alert fatigue, it was considered important not to include all possible confusions as a new alert: the potential contribution to the prevention of drug confusion should be weighed against the risk of alert fatigue.
47 CFR 10.310 - Federal alert gateway. [Reserved
Code of Federal Regulations, 2010 CFR
2010-10-01
... 47 Telecommunication 1 2010-10-01 2010-10-01 false Federal alert gateway. [Reserved] 10.310 Section 10.310 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM System Architecture § 10.310 Federal alert gateway. [Reserved] ...
47 CFR 10.310 - Federal alert gateway. [Reserved
Code of Federal Regulations, 2012 CFR
2012-10-01
... 47 Telecommunication 1 2012-10-01 2012-10-01 false Federal alert gateway. [Reserved] 10.310 Section 10.310 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM System Architecture § 10.310 Federal alert gateway. [Reserved] ...
47 CFR 10.310 - Federal alert gateway. [Reserved
Code of Federal Regulations, 2011 CFR
2011-10-01
... 47 Telecommunication 1 2011-10-01 2011-10-01 false Federal alert gateway. [Reserved] 10.310 Section 10.310 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM System Architecture § 10.310 Federal alert gateway. [Reserved] ...
Provider acceptance of an automated electronic alert for acute kidney injury
Oh, Janice; Bia, Joshua R.; Ubaid-Ullah, Muhamad; Testani, Jeffrey M.; Wilson, Francis Perry
2016-01-01
Background Clinical decision support systems, including electronic alerts, ideally provide immediate and relevant patient-specific information to improve clinical decision-making. Despite the growing capabilities of such alerts in conjunction with an expanding electronic medical record, there is a paucity of information regarding their perceived usefulness. We surveyed healthcare providers' opinions concerning the practicality and efficacy of a specific text-based automated electronic alert for acute kidney injury (AKI) in a single hospital during a randomized trial of AKI alerts. Methods Providers who had received at least one electronic AKI alert in the previous 6 months, as part of a separate randomized controlled trial (clinicaltrials.gov #01862419), were asked to complete a survey concerning their opinions about this specific AKI alert system. Individual approval of the alert system was defined by a provider's desire to continue receiving the alert after termination of the trial. Results A total of 98 individuals completed the survey, including 62 physicians, 27 pharmacists and 7 non-physician providers. Sixty-nine percent of responders approved the alert, with no significant difference among the various professions (P = 0.28). Alert approval was strongly correlated with the belief that the alerts improved patient care (P < 0.0001), and negatively correlated with the belief that alerts did not provide novel information (P = 0.0001). With each additional 30 days of trial duration, odds of approval decreased by 20% (3–35%) (P = 0.02). Conclusions The alert system was generally well received, although approval waned with time. Approval was correlated with the belief that this type of alert improved patient care. These findings suggest that perceived efficacy is critical to the success of future alert trials. PMID:27478598
Federal Register 2010, 2011, 2012, 2013, 2014
2013-08-30
...] Guide for the Evaluation of Alert and Notification Systems for Nuclear Power Plants, FEMA-REP-10, Rev. 1... the Guide for the Evaluation of Alert and Notification Systems for Nuclear Power Plants, FEMA-REP-10... Agency (FEMA) issued FEMA-REP-10, Guide for the Evaluation of Alert and Notification Systems for Nuclear...
NASA Astrophysics Data System (ADS)
Rahman, Nurul Hidayah Ab; Abdullah, Nurul Azma; Hamid, Isredza Rahmi A.; Wen, Chuah Chai; Jelani, Mohamad Shafiqur Rahman Mohd
2017-10-01
Closed-Circuit TV (CCTV) system is one of the technologies in surveillance field to solve the problem of detection and monitoring by providing extra features such as email alert or motion detection. However, detecting and alerting the admin on CCTV system may complicate due to the complexity to integrate the main program with an external Application Programming Interface (API). In this study, pixel processing algorithm is applied due to its efficiency and SMS alert is added as an alternative solution for users who opted out email alert system or have no Internet connection. A CCTV system with SMS alert (CMDSA) was developed using evolutionary prototyping methodology. The system interface was implemented using Microsoft Visual Studio while the backend components, which are database and coding, were implemented on SQLite database and C# programming language, respectively. The main modules of CMDSA are motion detection, capturing and saving video, image processing and Short Message Service (SMS) alert functions. Subsequently, the system is able to reduce the processing time making the detection process become faster, reduce the space and memory used to run the program and alerting the system admin instantly.
Wong, Adrian; Wright, Adam; Seger, Diane L; Amato, Mary G; Fiskio, Julie M; Bates, David
2017-08-23
Electronic health records (EHRs) with clinical decision support (CDS) have shown to be effective at improving patient safety. Despite this, alerts delivered as part of CDS are overridden frequently, which is of concern in the critical care population as this group may have an increased risk of harm. Our organization recently transitioned from an internally-developed EHR to a commercial system. Data comparing various EHR systems, especially after transitions between EHRs, are needed to identify areas for improvement. To compare the two systems and identify areas for potential improvement with the new commercial system at a single institution. Overridden medication-related CDS alerts were included from October to December of the systems' respective years (legacy, 2011; commercial, 2015), restricted to three intensive care units. The two systems were compared with regards to CDS presentation and override rates for four types of CDS: drug-allergy, drug-drug interaction (DDI), geriatric and renal alerts. A post hoc analysis to evaluate for adverse drug events (ADEs) potentially resulting from overridden alerts was performed for 'contraindicated' DDIs via chart review. There was a significant increase in provider exposure to alerts and alert overrides in the commercial system (commercial: n=5,535; legacy: n=1,030). Rates of overrides were higher for the allergy and DDI alerts (p<0.001) in the commercial system. Geriatric and renal alerts were significantly different in incidence and presentation between the two systems. No ADEs were identified in an analysis of 43 overridden contraindicated DDI alerts. The vendor system had much higher rates of both alerts and overrides, although we did not find evidence of harm in a review of DDIs which were overridden. We propose recommendations for improving our current system which may be helpful to other similar institutions; improving both alert presentation and the underlying knowledge base appear important.
ORIGINS OF ABSORPTION SYSTEMS OF CLASSICAL NOVA V2659 CYG (NOVA CYG 2014)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Arai, A.; Kawakita, H.; Shinnaka, Y.
2016-10-10
We report on high-dispersion spectroscopy results of a classical nova V2659 Cyg (Nova Cyg 2014) that are taken 33.05 days after the V -band maximum. The spectrum shows two distinct blueshifted absorption systems originating from H i, Fe ii, Ca ii, etc. The radial velocities of the absorption systems are −620 km s{sup −1}, and −1100 to −1500 km s{sup −1}. The higher velocity component corresponds to the P-Cygni absorption features frequently observed in low-resolution spectra. Much larger numbers of absorption lines are identified at the lower velocity. These mainly originate from neutral or singly ionized Fe-peak elements (Fe i,more » Ti ii, Cr ii, etc.). Based on the results of our spectroscopic observations, we discuss the structure of the ejecta of V2659 Cyg. We conclude that the low- and high-velocity components are likely to be produced by the outflow wind and the ballistic nova ejecta, respectively.« less
Naval Observatory Vector Astrometry Software (NOVAS) Version 3.1, Introducing a Python Edition
NASA Astrophysics Data System (ADS)
Barron, Eric G.; Kaplan, G. H.; Bangert, J.; Bartlett, J. L.; Puatua, W.; Harris, W.; Barrett, P.
2011-01-01
The Naval Observatory Vector Astrometry Software (NOVAS) is a source-code library that provides common astrometric quantities and transformations. NOVAS calculations are accurate at the sub-milliarcsecond level. The library can supply, in one or two subroutine or function calls, the instantaneous celestial position of any star or planet in a variety of coordinate systems. NOVAS also provides access to all of the building blocks that go into such computations. NOVAS Version 3.1 introduces a Python edition alongside the Fortran and C editions. The Python edition uses the computational code from the C edition and, currently, mimics the function calls of the C edition. Future versions will expand the functionality of the Python edition to harness the object-oriented nature of the Python language, and will implement the ability to handle large quantities of objects or observers using the array functionality in NumPy (a third-party scientific package for Python). NOVAS 3.1 also adds a module to transform GCRS vectors to the ITRS; the ITRS to GCRS transformation was already provided in NOVAS 3.0. The module that corrects an ITRS vector for polar motion has been modified to undo that correction upon demand. In the C edition, the ephemeris-access functions have been revised for use on 64-bit systems and for improved performance in general. NOVAS, including documentation, is available from the USNO website (http://www.usno.navy.mil/USNO/astronomical-applications/software-products/novas).
The Masses and Accretion Rates of White Dwarfs in Classical and Recurrent Novae
NASA Astrophysics Data System (ADS)
Shara, Michael M.; Prialnik, Dina; Hillman, Yael; Kovetz, Attay
2018-06-01
Models have long predicted that the frequency-averaged masses of white dwarfs (WDs) in Galactic classical novae are twice as large as those of field WDs. Only a handful of dynamically well-determined nova WDs masses have been published, leaving the theoretical predictions poorly tested. The recurrence time distributions and mass accretion rate distributions of novae are even more poorly known. To address these deficiencies, we have combined our extensive simulations of nova eruptions with the Strope et al. and Schaefer databases of outburst characteristics of Galactic classical and recurrent novae (RNe) to determine the masses of 92 WDs in novae. We find that the mean mass (frequency-averaged mean mass) of 82 Galactic classical novae is 1.06 (1.13) M ⊙, while the mean mass of 10 RNe is 1.31 M ⊙. These masses, and the observed nova outburst amplitude and decline time distributions allow us to determine the long-term mass accretion rate distribution of classical novae. Remarkably, that value is just 1.3 × 10‑10 M ⊙ yr‑1, which is an order of magnitude smaller than that of cataclysmic binaries in the decades before and after classical nova eruptions. This predicts that old novae become low-mass transfer rate systems, and hence dwarf novae, for most of the time between nova eruptions. We determine the mass accretion rates of each of the 10 known Galactic recurrent nova, finding them to be in the range of 10‑7–10‑8 M ⊙ yr‑1. We are able to predict the recurrence time distribution of novae and compare it with the predictions of population synthesis models.
47 CFR 10.240 - Notification to new subscribers of non-participation in CMAS.
Code of Federal Regulations, 2010 CFR
2010-10-01
...-participation in CMAS. 10.240 Section 10.240 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM Election to Participate in Commercial Mobile Alert System § 10.240... EMERGENCY ALERTS (Commercial Mobile Alert Service) [[CMS provider
47 CFR 11.56 - Obligation to process CAP-formatted EAS messages.
Code of Federal Regulations, 2013 CFR
2013-10-01
...), and Common Alerting Protocol, v. 1.2 USA Integrated Public Alert and Warning System Profile Version 1...) “Common Alerting Protocol, v. 1.2 USA Integrated Public Alert and Warning System Profile Version 1.0” (Oct...
47 CFR 11.56 - Obligation to process CAP-formatted EAS messages.
Code of Federal Regulations, 2012 CFR
2012-10-01
...), and Common Alerting Protocol, v. 1.2 USA Integrated Public Alert and Warning System Profile Version 1...) “Common Alerting Protocol, v. 1.2 USA Integrated Public Alert and Warning System Profile Version 1.0” (Oct...
47 CFR 11.56 - Obligation to process CAP-formatted EAS messages.
Code of Federal Regulations, 2014 CFR
2014-10-01
...), and Common Alerting Protocol, v. 1.2 USA Integrated Public Alert and Warning System Profile Version 1...) “Common Alerting Protocol, v. 1.2 USA Integrated Public Alert and Warning System Profile Version 1.0” (Oct...
Development and Implementation of Sepsis Alert Systems.
Harrison, Andrew M; Gajic, Ognjen; Pickering, Brian W; Herasevich, Vitaly
2016-06-01
Development and implementation of sepsis alert systems is challenging, particularly outside the monitored intensive care unit (ICU) setting. Barriers to wider use of sepsis alerts include evolving clinical definitions of sepsis, information overload, and alert fatigue, due to suboptimal alert performance. Outside the ICU, barriers include differences in health care delivery models, charting behaviors, and availability of electronic data. Current evidence does not support routine use of sepsis alert systems in clinical practice. Continuous improvement in the afferent and efferent aspects will help translate theoretic advantages into measurable patient benefit. Copyright © 2016 Elsevier Inc. All rights reserved.
Pilot Non-Conformance to Alerting System Commands
NASA Technical Reports Server (NTRS)
Pritchett, Amy R.; Hansman, R. John
1997-01-01
Instances of pilot non-conformance to alerting system commands have been identified in previous studies. Pilot non-conformance changes the final behavior of the system, and therefore may reduce actual performance from that anticipated. A simulator study has examined pilot non-conformance, using the task of collision avoidance during closely spaced parallel approaches as a case study. Consonance between the display and the alerting system was found to significantly improve subject agreement with automatic alerts. Based on these results, a more general discussion of the factors involved in pilot conformance is given, and design guidelines for alerting systems are given.
ERIC Educational Resources Information Center
WHITING, RICHARD; AND OTHERS
NOVA IS AN EXPERIMENTAL, 6-YEAR JUNIOR-SENIOR HIGH SCHOOL. ASPECTS OF THE PROGRAM INCLUDE THE TRIMESTER SYSTEM, THE CONTINUOUS PROGRESS CURRICULUM, TEAM TEACHING, A CLASS SCHEDULE OF FOUR 70-MINUTE PERIODS PER WEEK, THE USE OF DATA-PROCESSING EQUIPMENT, AND MODERN INSTRUCTIONAL AIDS. NOVA IS ORGANIZED CAMPUS-STYLE WITH INDIVIDUAL BUILDINGS DEVOTED…
Liverpool Telescope Spectroscopy of the Nova Eruption from V392 Persei
NASA Astrophysics Data System (ADS)
Darnley, M. J.; Copperwheat, C. M.; Harvey, E. J.; Healy, M. W.
2018-05-01
Here we report Liverpool Telescope (LT; Steele et al. 2004) spectroscopy of the recent nova eruption (ATel #11588) from the known dwarf nova system V392 Per. A Fermi & gamma;-ray detection of the eruption has also been reported (ATel #11590) along with additional photometry (ATel #11594).
47 CFR 10.320 - Provider alert gateway requirements.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 47 Telecommunication 1 2012-10-01 2012-10-01 false Provider alert gateway requirements. 10.320 Section 10.320 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM System Architecture § 10.320 Provider alert gateway requirements. This section specifies the functions...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-12-28
... Communication & Surveillance Systems (ACSS) Traffic Alert and Collision Avoidance System (TCAS) Units AGENCY... & Surveillance Systems (ACSS) Traffic Alert and Collision Avoidance System (TCAS) units during a flight test over... applies to Aviation Communication & Surveillance Systems (ACSS) Traffic Alert and Collision Avoidance...
NASA Technical Reports Server (NTRS)
1985-01-01
A visual alert system resulted from circuitry developed by Applied Cybernetics Systems for Langley as part of a space related telemetry system. James Campman, Applied Cybernetics president, left the company and founded Grace Industries, Inc. to manufacture security devices based on the Langley technology. His visual alert system combines visual and audible alerts for hearing impaired people. The company also manufactures an arson detection device called the electronic nose, and is currently researching additional applications of the NASA technology.
Lin, Shu-Wen; Kang, Wen-Yi; Lin, Dong-Tsamn; Lee, James; Wu, Fe-Lin; Chen, Chuen-Liang; Tseng, Yufeng J
2014-01-01
Computerized alert and reminder systems have been widely accepted and applied to various patient care settings, with increasing numbers of clinical laboratories communicating critical laboratory test values to professionals via either manual notification or automated alerting systems/computerized reminders. Warfarin, an oral anticoagulant, exhibits narrow therapeutic range between treatment response and adverse events. It requires close monitoring of prothrombin time (PT)/international normalized ratio (INR) to ensure patient safety. This study was aimed to evaluate clinical outcomes of patients on warfarin therapy following implementation of a Personal Handy-phone System-based (PHS) alert system capable of generating and delivering text messages to communicate critical PT/INR laboratory results to practitioners' mobile phones in a large tertiary teaching hospital. A retrospective analysis was performed comparing patient clinical outcomes and physician prescribing behavior following conversion from a manual laboratory result alert system to an automated system. Clinical outcomes and practitioner responses to both alert systems were compared. Complications to warfarin therapy, warfarin utilization, and PT/INR results were evaluated for both systems, as well as clinician time to read alert messages, time to warfarin therapy modification, and monitoring frequency. No significant differences were detected in major hemorrhage and thromboembolism, warfarin prescribing patterns, PT/INR results, warfarin therapy modification, or monitoring frequency following implementation of the PHS text alert system. In both study periods, approximately 80% of critical results led to warfarin discontinuation or dose reduction. Senior physicians' follow-up response time to critical results was significantly decreased in the PHS alert study period (46.3% responded within 1 day) compared to the manual notification study period (24.7%; P = 0.015). No difference in follow-up response time was detected for junior physicians. Implementation of an automated PHS-based text alert system did not adversely impact clinical or safety outcomes of patients on warfarin therapy. Approximately 80% immediate recognition of text alerts was achieved. The potential benefits of an automated PHS alert for senior physicians were demonstrated.
77 FR 26701 - Review of the Emergency Alert System
Federal Register 2010, 2011, 2012, 2013, 2014
2012-05-07
... Emergency Alert System AGENCY: Federal Communications Commission. ACTION: Final rule. SUMMARY: In this document, the Federal Communications Commission (Commission) amends its rules governing the Emergency Alert... the manner in which EAS Participants must be able to receive alert messages formatted in the Common...
Page, N; Baysari, M T; Westbrook, J I
2017-09-01
To assess the evidence of the effectiveness of different categories of interruptive medication prescribing alerts to change prescriber behavior and/or improve patient outcomes in hospital computerized provider order entry (CPOE) systems. PubMed, Embase, CINAHL and the Cochrane Library were searched for relevant articles published between January 2000 and February 2016. Studies were included if they compared the outcomes of automatic, interruptive medication prescribing alert/s to a control/comparison group to determine alert effectiveness. Twenty-three studies describing 32 alerts classified into 11 alert categories were identified. The most common alert categories studied were drug-condition interaction (n=6), drug-drug interaction alerts (n=6) and corollary order alerts (n=6). All 23 papers investigated the effect of the intervention alert on at least one outcome measure of prescriber behavior. Just over half of the studies (53%, n=17) reported a statistically significant beneficial effect from the intervention alert; 34% (n=11) reported no statistically significant effect, and 6% (n=2) reported a significant detrimental effect. Two studies also evaluated the effect of alerts on patient outcome measures; neither finding that patient outcomes significantly improved following alert implementation (6%, n=2). The greatest volume of evidence relates to three alert categories: drug-condition, drug-drug and corollary order alerts. Of these, drug-condition alerts had the greatest number of studies reporting positive effects (five out of six studies). Only two of six studies of drug-drug interaction and one of six of corollary alerts reported positive benefits. The current evidence-base does not show a clear indication that particular categories of alerts are more effective than others. While the majority of alert categories were shown to improve outcomes in some studies, there were also many cases where outcomes did not improve. This lack of evidence hinders decisions about the amount and type of decision support that should be integrated into CPOE systems to increase safety while reducing the risk of alert fatigue. Virtually no studies have sought to investigate the impact on changes to prescriber behavior and outcomes overall when alerts from multiple categories are incorporated within the same system. Copyright © 2017 Elsevier B.V. All rights reserved.
Integration of the Super Nova early warning system with the NOvA Trigger
DOE Office of Scientific and Technical Information (OSTI.GOV)
Habig, Alec; Zirnstein, Jan
The NOvA experiment, with a baseline of 810km, samples Fermilab’s upgraded NuMI beam with a Near Detector on-site and a Far Detector (FD) at Ash River, MN, to observe oscillations of muon neutrinos. The 344,064 liquid scintillator-filled cells of the 14 kton FD provide high granularity of a large detector mass and enable us to also study non-accelerator based neutrinos with our Data Driven Trigger framework. This paper will focus on the real time integration of the SNEWS with the NOvA Trigger where we have set up an XML-RPC based messaging system to inject the SNEWS signal directly into ourmore » trigger. In conclusion, this presents a departure from the E-Mail based notification mechanism used by SNEWS in the past and allows NOvA more control over propagation and transmission timing.« less
Integration of the Super Nova early warning system with the NOvA Trigger
Habig, Alec; Zirnstein, Jan
2015-12-23
The NOvA experiment, with a baseline of 810km, samples Fermilab’s upgraded NuMI beam with a Near Detector on-site and a Far Detector (FD) at Ash River, MN, to observe oscillations of muon neutrinos. The 344,064 liquid scintillator-filled cells of the 14 kton FD provide high granularity of a large detector mass and enable us to also study non-accelerator based neutrinos with our Data Driven Trigger framework. This paper will focus on the real time integration of the SNEWS with the NOvA Trigger where we have set up an XML-RPC based messaging system to inject the SNEWS signal directly into ourmore » trigger. In conclusion, this presents a departure from the E-Mail based notification mechanism used by SNEWS in the past and allows NOvA more control over propagation and transmission timing.« less
Wireless clinical alerts and patient outcomes in the surgical intensive care unit.
Major, Kevin; Shabot, M Michael; Cunneen, Scott
2002-12-01
Errors in medicine have gained public interest since the Institute of Medicine published its 1999 report on this subject. Although errors of commission are frequently cited, errors of omission can be equally serious. A computerized surgical intensive care unit (SICU) information system when coupled to an event-driven alerting engine has the potential to reduce errors of omission for critical intensive care unit events. Automated alerts and patient outcomes were prospectively collected for all patients admitted to a tertiary-care SICU for a 2-year period. During the study period 3,973 patients were admitted to the SICU and received 13,608 days of care. A total of 15,066 alert pages were sent including alerts for physiologic condition (6,163), laboratory data (4,951), blood gas (3,774), drug allergy (130), and toxic drug levels (48). Admission Simplified Acute Physiology Score and Acute Physiology and Chronic Health Evaluation II score, SICU lengths of stay, and overall mortality rates were significantly higher in patients who triggered the alerting system. Patients triggering the alert paging system were 49.4 times more likely to die in the SICU compared with patients who did not generate an alert. Even after transfer to floor care the patients who triggered the alerting system were 5.7 times more likely to die in the hospital. An alert page identifies patients who will stay in the SICU longer and have a significantly higher chance of death compared with patients who do not trigger the alerting system.
The distances of the Galactic Novae
NASA Astrophysics Data System (ADS)
Ozdonmez, Aykut; Guver, Tolga; Cabrera-Lavers, Antonio; Ak, Tansel
2016-07-01
Using location of the RC stars on the CMDs obtained from the UKIDSS, VISTA and 2MASS photometry, we have derived the reddening-distance relations towards each Galactic nova for which at least one independent reddening measurement exists. We were able to determine the distances of 72 Galactic novae and set lower limits on the distances of 45 systems. The reddening curves of the systems are presented. These curves can be also used to estimate reddening or the distance of any source, whose location is close to the position of the nova in our sample. The distance measurement method in our study can be easily applicable to any source, especially for ones that concentrated along the Galactic plane.
An IDS Alerts Aggregation Algorithm Based on Rough Set Theory
NASA Astrophysics Data System (ADS)
Zhang, Ru; Guo, Tao; Liu, Jianyi
2018-03-01
Within a system in which has been deployed several IDS, a great number of alerts can be triggered by a single security event, making real alerts harder to be found. To deal with redundant alerts, we propose a scheme based on rough set theory. In combination with basic concepts in rough set theory, the importance of attributes in alerts was calculated firstly. With the result of attributes importance, we could compute the similarity of two alerts, which will be compared with a pre-defined threshold to determine whether these two alerts can be aggregated or not. Also, time interval should be taken into consideration. Allowed time interval for different types of alerts is computed individually, since different types of alerts may have different time gap between two alerts. In the end of this paper, we apply proposed scheme on DAPRA98 dataset and the results of experiment show that our scheme can efficiently reduce the redundancy of alerts so that administrators of security system could avoid wasting time on useless alerts.
Some human factors issues in the development and evaluation of cockpit alerting and warning systems
NASA Technical Reports Server (NTRS)
Randle, R. J., Jr.; Larsen, W. E.; Williams, D. H.
1980-01-01
A set of general guidelines for evaluating a newly developed cockpit alerting and warning system in terms of human factors issues are provided. Although the discussion centers around a general methodology, it is made specifically to the issues involved in alerting systems. An overall statement of the current operational problem is presented. Human factors problems with reference to existing alerting and warning systems are described. The methodology for proceeding through system development to system test is discussed. The differences between traditional human factors laboratory evaluations and those required for evaluation of complex man-machine systems under development are emphasized. Performance evaluation in the alerting and warning subsystem using a hypothetical sample system is explained.
76 FR 3064 - Travelers Information Stations
Federal Register 2010, 2011, 2012, 2013, 2014
2011-01-19
... phone numbers when local 911 systems fail, terror threat alert levels, public health warnings ``and all... Alerts, alternate phone numbers when local 911 systems fail, terror threat alert levels, public health..., alternate phone numbers to 911, terror threat alert levels, and public health warnings--do not appear to be...
Discovery of a New Classical Nova Shell Around a Nova-like Cataclysmic Variable
NASA Astrophysics Data System (ADS)
Guerrero, Martín A.; Sabin, Laurence; Tovmassian, Gagik; Santamaría, Edgar; Michel, Raul; Ramos-Larios, Gerardo; Alarie, Alexandre; Morisset, Christophe; Bermúdez Bustamante, Luis C.; González, Chantal P.; Wright, Nicholas J.
2018-04-01
The morphology and optical spectrum of IPHASX J210204.7+471015, a nebula classified as a possible planetary nebula are, however, strikingly similar to those of AT Cnc, a classical nova shell around a dwarf nova. To investigate its true nature, we have obtained high-resolution narrowband [O III] and [N II] images and deep optical spectra. The nebula shows an arc of [N II]-bright knots notably enriched in nitrogen, while an [O III]-bright bow shock is progressing throughout the ISM. Diagnostic line ratios indicate that shocks are associated with the arc and bow shock. The central star of this nebula has been identified by its photometric variability. Time-resolved photometric and spectroscopic data of this source reveal a period of 4.26 hr, which is attributed to a binary system. The optical spectrum is notably similar to that of RW Sex, a cataclysmic variable star (CV) of the UX UMa nova-like (NL) type. Based on these results, we propose that IPHASX J210204.7 + 471015 is a classical nova shell observed around a CV-NL system in quiescence.
Wickens, Christopher; Colcombe, Angela
2007-10-01
Performance consequences related to integrating an imperfect alert within a complex task domain were examined in two experiments. Cockpit displays of traffic information (CDTIs) are being designed for use in airplane cockpits as responsibility for safe separation becomes shared between pilots and controllers. Of interest in this work is how characteristics of the alarm system such as threshold, modality, and number of alert levels impact concurrent task (flight control) performance and response to potential conflicts. Student pilots performed a tracking task analogous to flight control while simultaneously monitoring for air traffic conflicts with the aid of a CDTI alert as the threshold, modality, and level of alert was varied. As the alerting system became more prone to false alerts, pilot compliance decreased and concurrent performance improved. There was some evidence of auditory preemption with auditory alerts as the false alarm rate increased. Finally, there was no benefit to a three-level system over a two-level system. There is justification for increased false alarm rates, as miss-prone systems appear to be costly. The 4:1 false alarm to miss ratio employed here improved accuracy and concurrent task performance. More research needs to address the potential benefits of likelihood alerting. The issues addressed in this research can be applied to any imperfect alerting system such as in aviation, driving, or air traffic control. It is crucial to understand the performance consequences of new technology and the efficacy of potential mitigating design features within the specific context desired.
Balasuriya, Lilanthi; Vyles, David; Bakerman, Paul; Holton, Vanessa; Vaidya, Vinay; Garcia-Filion, Pamela; Westdorp, Joan; Sanchez, Christine; Kurz, Rhonda
2017-09-01
An enhanced dose range checking (DRC) system was developed to evaluate prescription error rates in the pediatric intensive care unit and the pediatric cardiovascular intensive care unit. An enhanced DRC system incorporating "soft" and "hard" alerts was designed and implemented. Practitioner responses to alerts for patients admitted to the pediatric intensive care unit and the pediatric cardiovascular intensive care unit were retrospectively reviewed. Alert rates increased from 0.3% to 3.4% after "go-live" (P < 0.001). Before go-live, all alerts were soft alerts. In the period after go-live, 68% of alerts were soft alerts and 32% were hard alerts. Before go-live, providers reduced doses only 1 time for every 10 dose alerts. After implementation of the enhanced computerized physician order entry system, the practitioners responded to soft alerts by reducing doses to more appropriate levels in 24.7% of orders (70/283), compared with 10% (3/30) before go-live (P = 0.0701). The practitioners deleted orders in 9.5% of cases (27/283) after implementation of the enhanced DRC system, as compared with no cancelled orders before go-live (P = 0.0774). Medication orders that triggered a soft alert were submitted unmodified in 65.7% (186/283) as compared with 90% (27/30) of orders before go-live (P = 0.0067). After go-live, 28.7% of hard alerts resulted in a reduced dose, 64% resulted in a cancelled order, and 7.4% were submitted as written. Before go-live, alerts were often clinically irrelevant. After go-live, there was a statistically significant decrease in orders that were submitted unmodified and an increase in the number of orders that were reduced or cancelled.
Seidling, Hanna M; Phansalkar, Shobha; Seger, Diane L; Paterno, Marilyn D; Shaykevich, Shimon; Haefeli, Walter E
2011-01-01
Background Clinical decision support systems can prevent knowledge-based prescription errors and improve patient outcomes. The clinical effectiveness of these systems, however, is substantially limited by poor user acceptance of presented warnings. To enhance alert acceptance it may be useful to quantify the impact of potential modulators of acceptance. Methods We built a logistic regression model to predict alert acceptance of drug–drug interaction (DDI) alerts in three different settings. Ten variables from the clinical and human factors literature were evaluated as potential modulators of provider alert acceptance. ORs were calculated for the impact of knowledge quality, alert display, textual information, prioritization, setting, patient age, dose-dependent toxicity, alert frequency, alert level, and required acknowledgment on acceptance of the DDI alert. Results 50 788 DDI alerts were analyzed. Providers accepted only 1.4% of non-interruptive alerts. For interruptive alerts, user acceptance positively correlated with frequency of the alert (OR 1.30, 95% CI 1.23 to 1.38), quality of display (4.75, 3.87 to 5.84), and alert level (1.74, 1.63 to 1.86). Alert acceptance was higher in inpatients (2.63, 2.32 to 2.97) and for drugs with dose-dependent toxicity (1.13, 1.07 to 1.21). The textual information influenced the mode of reaction and providers were more likely to modify the prescription if the message contained detailed advice on how to manage the DDI. Conclusion We evaluated potential modulators of alert acceptance by assessing content and human factors issues, and quantified the impact of a number of specific factors which influence alert acceptance. This information may help improve clinical decision support systems design. PMID:21571746
77 FR 8181 - Airworthiness Directives; Fokker Services B.V. Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2012-02-14
... hydraulic system and accompanying alerts for ``hydraulic system 1 low quantity'' and ``hydraulic system 2... of the hydraulic system and accompanying alerts for ``hydraulic system 1 low quantity'' and... for these alerts may give the false impression that the stabiliser is still hydraulically controllable...
NASA Astrophysics Data System (ADS)
Harvey, E.; Redman, M. P.; Boumis, P.; Akras, S.
2016-10-01
Aims: The shaping mechanisms of old nova remnants are probes for several important and unexplained processes, such as dust formation and the structure of evolved star nebulae. To gain a more complete understanding of the dynamics of the GK Per (1901) remnant, an examination of symmetry of the nova shell is explored, followed by a kinematical analysis of the previously detected jet-like feature in the context of the surrounding fossil planetary nebula. Methods: Faint-object high-resolution echelle spectroscopic observations and imaging were undertaken covering the knots which comprise the nova shell and the surrounding nebulosity. New imaging from the Aristarchos telescope in Greece and long-slit spectra from the Manchester Echelle Spectrometer instrument at the San Pedro Mártir observatory in Mexico were obtained, supplemented with archival observations from several other optical telescopes. Position-velocity arrays are produced of the shell, and also individual knots, and are then used for morpho-kinematic modelling with the shape code. The overall structure of the old knotty nova shell of GK Per and the planetary nebula in which it is embedded is then analysed. Results: Evidence is found for the interaction of knots with each other and with a wind component, most likely the periodic fast wind emanating from the central binary system. We find that a cylindrical shell with a lower velocity polar structure gives the best model fit to the spectroscopy and imaging. We show in this work that the previously seen jet-like feature is of low velocity. Conclusions: The individual knots have irregular tail shapes; we propose here that they emanate from episodic winds from ongoing dwarf nova outbursts by the central system. The nova shell is cylindrical, not spherical, and the symmetry axis relates to the inclination of the central binary system. Furthermore, the cylinder axis is aligned with the long axis of the bipolar planetary nebula in which it is embedded. Thus, the central binary system is responsible for the bipolarity of the planetary nebula and the cylindrical nova shell. The gradual planetary nebula ejecta versus sudden nova ejecta is the reason for the different degrees of bipolarity. We propose that the "jet" feature is an illuminated lobe of the fossil planetary nebula that surrounds the nova shell.
Discovery of an old nova shell surrounding the cataclysmic variable V1315 Aql
NASA Astrophysics Data System (ADS)
Sahman, D. I.; Dhillon, V. S.; Littlefair, S. P.; Hallinan, G.
2018-07-01
Following our tentative discovery of a faint shell around V1315 Aql reported in Sahman et al., we undertook deep Hα imaging and intermediate-resolution spectroscopy of the shell. We find that the shell has its geometric centre located on V1315 Aql. The mass, spectral features, and density of the shell are consistent with other nova shells, rather than planetary nebulae or supernova remnants. The radial velocity of the shell is consistent with the systemic velocity of V1315 Aql. We believe this evidence strongly suggests that the shell originates from an earlier nova event. This is the first nova shell discovered around a nova-like and supports the theory of nova-induced cycles in mass transfer rates (hibernation theory) first proposed by Shara et al.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Doak, Justin E.; Ingram, Joe; Johnson, Josh
2016-01-06
In the cyber security operations of a typical organization, data from multiple sources are monitored, and when certain conditions in the data are met, an alert is generated in an alert management system. Analysts inspect these alerts to decide if any deserve promotion to an event requiring further scrutiny. This triage process is manual, time-consuming, and detracts from the in-depth investigation of events. We have created a software system that uses supervised machine learning to automatically prioritize these alerts. In particular we utilize active learning to make efficient use of the pool of unlabeled alerts, thereby improving the performance ofmore » our ranking models over passive learning. We have demonstrated the effectiveness of our system on a large, real-world dataset of cyber security alerts.« less
75 FR 25842 - Notice of a Grant With the Public Broadcasting Service
Federal Register 2010, 2011, 2012, 2013, 2014
2010-05-10
... development of the Commercial Mobile Alert System (CMAS), a national system to distribute emergency alert...-27 (Feb. 8, 2006) (establishing the National Alert and Tsunami Warning Program); Section 606 of the... requirements to support the distribution of geographically targeted alerts by commercial mobile service...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-05-14
... practice recommendations on emergency alerting systems such as promoting E9-1-1 reliability and alerting platforms--Emergency Alert System and Common Alerting Protocol. DATES: June 6, 2012. ADDRESSES: Federal... Advisory Committee that will provide recommendations to the FCC regarding best practices and actions the...
Scordalakes, Constantine; delRosario, Robert; Shimer, Andrew; Stankiewicz, Russell
2018-01-01
Compare amenorrhea rate, menstrual symptoms, patient satisfaction, and adverse events in women who underwent endometrial ablation with the NovaSure versus the Minerva radiofrequency ablation systems. We surveyed 189 premenopausal women (mean 40.8±6.2 years old) who underwent endometrial ablation for abnormal uterine bleeding using the NovaSure (n=97) or Minerva (n=92) systems, at four private US gynecology clinics, and whose procedure date was after July 2015 with follow-up ≥3 months. Women were surveyed an average of 11.3±3.9 months (range 137-532 days) after ablation. The subject-reported amenorrhea rate was 52% higher in NovaSure subjects than Minerva subjects (64% and 42%, respectively; p =0.004). Age and bleeding cyclicity did not affect amenorrhea rate in either group. Normal-to-no bleeding was reported by >90% of subjects after either treatment. NovaSure was significantly more effective than Minerva at reducing pad/tampon use in women with any residual bleeding (2.4±5.2 items/day versus 4.7±5.5 items/day, p =0.049). NovaSure was significantly more effective than Minerva at reducing premenstrual syndrome (PMS) symptoms ( p =0.019) and menstrual pain ( p =0.003), and more NovaSure subjects (94%) than Minerva subjects (78%) were satisfied with clinical outcomes ( p =0.003). Adverse events did not differ by treatment; three women in each group progressed to hysterectomy. While overall bleeding reduction in premenopausal women with abnormal uterine bleeding was excellent with either endometrial ablation system, NovaSure treatment resulted in a higher patient-reported 1-year amenorrhea rate, and women with residual bleeding used fewer pads and tampons than Minerva-treated women. Additionally, NovaSure subjects reported better menstrual-related life quality and PMS symptom alleviation, and greater satisfaction with outcomes than Minerva-treated women.
Faure, D; Payrastre, O; Auchet, P
2005-01-01
Since January 2000, the sewerage network of a very urbanised catchment area in the Greater Nancy Urban Community has been operated according to the alarms generated in real time by a storm alert system using weather radar data. This alert system is based on an automatic identification of intense rain cells in the radar images. This paper presents the characteristics of this alert system and synthesises the main results of two complementary studies realised in 2002 in order to estimate the relevance and the operational effectiveness of the alert system. The first study consisted in an off-line analysis of almost 50,000 intense rain cells detected in four years of historical radar data. The second study was an analysis of the experience feedback after two years of operational use of this alert system. The results of these studies are discussed in function of the initial operational objectives.
Flight crew interface aspects of forward-looking airborne windshear detection systems
NASA Technical Reports Server (NTRS)
Anderson, Charles D.; Carbaugh, David C.
1993-01-01
The goal of this research effort was to conduct analyses and research which could provide guidelines for design of the crew interface of an integrated windshear system. Addressed were HF issues, crew/system requirements, candidate display formats, alerting criteria, and crew procedures. A survey identified five flight management issues as top priority: missed alert acceptability; avoidance distance needed; false alert acceptability; nuisance rate acceptability; and crew procedures. Results of a simulation study indicated that the warning time for a look-ahead alert needs to be between 11 and 36 seconds (target of 23 seconds) before the reactive system triggers in order to be effective. Pilots considered the standard go-around maneuver most appropriate for look-ahead alerts, and the escape maneuvers used did not require lateral turns. Prototype display formats were reviewed or developed for alerting the crew; providing guidance to avoid or escape windshear; and status displays to provide windshear situational awareness. The three alerting levels now in use were considered appropriate, with a fourth (time-critical) level as a possible addition, although many reviewers felt only two levels of alerting were needed. Another survey gathered expert opinion on what crew procedures and alerting criteria should be used for look-ahead, or integrated, windshear systems, with a wide diversity of opinion in these areas.
NASA Astrophysics Data System (ADS)
Munari, U.; Banerjee, D. P. K.
2018-03-01
Pre-outburst 2MASS and WISE photometry of Nova Sco 2014 (V1534 Sco) has suggested the presence of a cool giant at the location of the nova in the sky. The spectral evolution recorded for the nova did not, however, support a direct partnership because no flash-ionized wind and no deceleration of the ejecta were observed, contrary to the behaviour displayed by other novae which erupted within symbiotic binaries like V407 Cyg or RS Oph. We have therefore obtained 0.8-2.5 μm spectra of the remnant of Nova Sco 2014 in order to ascertain if a cool giant is indeed present and if it is physically associated with the nova. The spectrum shows the presence of a M6III giant, reddened by E(B - V) = 1.20, displaying the typical and narrow emission-line spectrum of a symbiotic star, including He I 1.0830 μm with a deep P-Cyg profile. This makes Nova Sco 2014 a new member of the exclusive club of novae that erupt within a symbiotic binary. Nova Sco 2014 shows that a nova erupting within a symbiotic binary does not always come with a deceleration of the ejecta, contrary to the common belief. Many other similar systems may lay hidden in past novae, especially in those that erupted prior to the release of the 2MASS all-sky infrared survey, which could be profitably cross-matched now against them.
Advanced alerting features: displaying new relevant data and retracting alerts.
Kuperman, G. J.; Hiltz, F. L.; Teich, J. M.
1997-01-01
We added two advanced features to our automated alerting system. The first feature identifies and displays, at the time an alert is reviewed, relevant data filed between the login time of a specimen leading to an alerting result and the time the alert is reviewed. Relevant data is defined as data of the same kind as generated the alert. The other feature retracts alerts when the alerting value is edited and no longer satisfies the alerting criteria. We evaluated the two features for a 14-week period (new relevant data) and a 6-week period (retraction). Of a total of 1104 alerts in the 14-week evaluation, 286 (25.9%) had new relevant data displayed at alert review time. Of the 286, 75.2% were due to additions of comments to the original piece of alerting data; 24.1% were due to new or pending laboratory results of the same type that generated the alert. Two alerts (out of 490) were retracted in a 6 week period. We conclude that in our system, new clinically relevant data is often added between the time of specimen login and the time that an alerting result from that specimen is reviewed. Retractions occur rarely but are important to detect and communicate. PMID:9357625
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shara, Michael M.; Doyle, Trisha; Lauer, Tod R.
The extensive grid of numerical simulations of nova eruptions first predicted that some classical novae might significantly deviate from the Maximum Magnitude–Rate of Decline (MMRD) relation, which purports to characterize novae as standard candles. Kasliwal et al. have announced the observational detection of a new class of faint, fast classical novae in the Andromeda galaxy. These objects deviate strongly from the MMRD relationship, as predicted by Yaron et al. Recently, Shara et al. reported the first detections of faint, fast novae in M87. These previously overlooked objects are as common in the giant elliptical galaxy M87 as they are inmore » the giant spiral M31; they comprise about 40% of all classical nova eruptions and greatly increase the observational scatter in the MMRD relation. We use the extensive grid of the nova simulations of Yaron et al. to identify the underlying causes of the existence of faint, fast novae. These are systems that have accreted, and can thus eject, only very low-mass envelopes, of the order of 10 –7–10 –8 M ⊙, on massive white dwarfs. Such binaries include, but are not limited to, the recurrent novae. As a result, these same models predict the existence of ultrafast novae that display decline times, t 2, to be as short as five hours. We outline a strategy for their future detection.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shara, Michael M.; Doyle, Trisha; Zurek, David
The extensive grid of numerical simulations of nova eruptions from the work of Yaron et al. first predicted that some classical novae might significantly deviate from the Maximum Magnitude–Rate of Decline (MMRD) relation, which purports to characterize novae as standard candles. Kasliwal et al. have announced the observational detection of a new class of faint, fast classical novae in the Andromeda galaxy. These objects deviate strongly from the MMRD relationship, as predicted by Yaron et al. Recently, Shara et al. reported the first detections of faint, fast novae in M87. These previously overlooked objects are as common in the giantmore » elliptical galaxy M87 as they are in the giant spiral M31; they comprise about 40% of all classical nova eruptions and greatly increase the observational scatter in the MMRD relation. We use the extensive grid of the nova simulations of Yaron et al. to identify the underlying causes of the existence of faint, fast novae. These are systems that have accreted, and can thus eject, only very low-mass envelopes, of the order of 10{sup −7}–10{sup −8} M {sub ⊙}, on massive white dwarfs. Such binaries include, but are not limited to, the recurrent novae. These same models predict the existence of ultrafast novae that display decline times, t {sub 2,} to be as short as five hours. We outline a strategy for their future detection.« less
Shara, Michael M.; Doyle, Trisha; Lauer, Tod R.; ...
2017-04-20
The extensive grid of numerical simulations of nova eruptions first predicted that some classical novae might significantly deviate from the Maximum Magnitude–Rate of Decline (MMRD) relation, which purports to characterize novae as standard candles. Kasliwal et al. have announced the observational detection of a new class of faint, fast classical novae in the Andromeda galaxy. These objects deviate strongly from the MMRD relationship, as predicted by Yaron et al. Recently, Shara et al. reported the first detections of faint, fast novae in M87. These previously overlooked objects are as common in the giant elliptical galaxy M87 as they are inmore » the giant spiral M31; they comprise about 40% of all classical nova eruptions and greatly increase the observational scatter in the MMRD relation. We use the extensive grid of the nova simulations of Yaron et al. to identify the underlying causes of the existence of faint, fast novae. These are systems that have accreted, and can thus eject, only very low-mass envelopes, of the order of 10 –7–10 –8 M ⊙, on massive white dwarfs. Such binaries include, but are not limited to, the recurrent novae. As a result, these same models predict the existence of ultrafast novae that display decline times, t 2, to be as short as five hours. We outline a strategy for their future detection.« less
Advanced LED warning system for rural intersections : phase 2 (ALERT-2) : final report.
DOT National Transportation Integrated Search
2014-02-01
This report presents findings of the second phase of the Advanced LED Warning System for Rural : Intersections (ALERT) project. Since it is the next generation of the same system, the second phase : system is referred to as the ALERT-2 system while t...
Geo-targeted Weather Alerts Coming to Millions of Mobile Devices
NASA Astrophysics Data System (ADS)
Gerber, M.
2011-12-01
The Personal Localized Alert Network (PLAN), aka Commercial Mobile Alert System (CMAS), is readying for roll out and will be broadcasting emergency public alerts to millions of cell phones by the middle of 2012. Learn how the National Weather Serivce (NWS) is supplying PLAN with geo-referenced weather alert information in the industry standard Common Alerting Protocol (CAP) format and how you can access this same information for integration with mobile devices, other consumer electronics, and decision support systems. Information will also be provided on the NWS' new collaborative venue that encourages wide participation in the evolution and use of NWS CAP alerts in a variety of applications.
The inter-outburst behavior of cataclysmic variables
NASA Technical Reports Server (NTRS)
Szkody, Paula; Mattei, Janet A.; Waagen, Elizabeth O.; Stablein, Clay
1990-01-01
Existing International Ultraviolet Explorer (IUE) and American Association of Variable Star Observers (AAVSO) archive data was used to accomplish a large scale study of what happens to the ultraviolet flux of accretion disk systems during the quiescent intervals between outbursts and how it relates to the preceding outburst characteristics of amplitude and width. The data sample involved multiple IUE observations for 16 dwarf novae and 8 novae along with existing optical coverage. Results indicate that most systems show correlated ultraviolet (UV) flux behavior with interoutburst phase, with 60 percent of the dwarf novae and 50 percent of the novae having decreasing flux trends while 33 percent of the dwarf novae and 38 percent of the novae show rising UV flux during the quiescent interval. All of the dwarf novae with decreasing UV fluxes at 1475A have orbital periods longer than 4.4 hours, while all (except BV Cen) with flat or rising fluxes at 1475A have orbital periods less than two hours. There are not widespread correlations of the UV fluxes with the amplitude of the preceding outburst and no correlations with the width of the outburst. From a small sample (7) that have relatively large quiescent V magnitude changes between the IUE observations, most show a strong correlation between the UV and optical continuum. Interpretation of the results is complicated by not being able to determine how much the white dwarf contributes to the ultraviolet flux. However, it is now evident that noticeable changes are occurring in the hot zones in accreting systems long after the outburst, and not only for systems that are dominated by the white dwarf. Whether these differences are due to different outburst mechanisms or to changes on white dwarfs which provide varying contributions to the UV flux remains to be determined.
DOT National Transportation Integrated Search
2010-08-01
This report presents the results of an evaluation of Caltrans District 3 Regional Transportation Management Centers (RTMC) implementation of a weather alert notification system. This alert system was selected for implementation from among several ...
Sensitivity and specificity of dosing alerts for dosing errors among hospitalized pediatric patients
Stultz, Jeremy S; Porter, Kyle; Nahata, Milap C
2014-01-01
Objectives To determine the sensitivity and specificity of a dosing alert system for dosing errors and to compare the sensitivity of a proprietary system with and without institutional customization at a pediatric hospital. Methods A retrospective analysis of medication orders, orders causing dosing alerts, reported adverse drug events, and dosing errors during July, 2011 was conducted. Dosing errors with and without alerts were identified and the sensitivity of the system with and without customization was compared. Results There were 47 181 inpatient pediatric orders during the studied period; 257 dosing errors were identified (0.54%). The sensitivity of the system for identifying dosing errors was 54.1% (95% CI 47.8% to 60.3%) if customization had not occurred and increased to 60.3% (CI 54.0% to 66.3%) with customization (p=0.02). The sensitivity of the system for underdoses was 49.6% without customization and 60.3% with customization (p=0.01). Specificity of the customized system for dosing errors was 96.2% (CI 96.0% to 96.3%) with a positive predictive value of 8.0% (CI 6.8% to 9.3). All dosing errors had an alert over-ridden by the prescriber and 40.6% of dosing errors with alerts were administered to the patient. The lack of indication-specific dose ranges was the most common reason why an alert did not occur for a dosing error. Discussion Advances in dosing alert systems should aim to improve the sensitivity and positive predictive value of the system for dosing errors. Conclusions The dosing alert system had a low sensitivity and positive predictive value for dosing errors, but might have prevented dosing errors from reaching patients. Customization increased the sensitivity of the system for dosing errors. PMID:24496386
Wearable PPG sensor based alertness scoring system.
Dey, Jishnu; Bhowmik, Tanmoy; Sahoo, Saswata; Tiwari, Vijay Narayan
2017-07-01
Quantifying mental alertness in today's world is important as it enables the person to adopt lifestyle changes for better work efficiency. Miniaturized sensors in wearable devices have facilitated detection/monitoring of mental alertness. Photoplethysmography (PPG) sensors through Heart Rate Variability (HRV) offer one such opportunity by providing information about one's daily alertness levels without requiring any manual interference from the user. In this paper, a smartwatch based alertness estimation system is proposed. Data collected from PPG sensor of smartwatch is processed and fed to machine learning based model to get a continuous alertness score. Utility functions are designed based on statistical analysis to give a quality score on different stages of alertness such as awake, long sleep and short duration power nap. An intelligent data collection approach is proposed in collaboration with the motion sensor in the smartwatch to reduce battery drainage. Overall, our proposed wearable based system provides a detailed analysis of alertness over a period in a systematic and optimized manner. We were able to achieve an accuracy of 80.1% for sleep/awake classification along with alertness score. This opens up the possibility for quantifying alertness levels using a single PPG sensor for better management of health related activities including sleep.
Closing the Loop in ICU Decision Support: Physiologic Event Detection, Alerts, and Documentation
Norris, Patrick R.; Dawant, Benoit M.
2002-01-01
Automated physiologic event detection and alerting is a challenging task in the ICU. Ideally care providers should be alerted only when events are clinically significant and there is opportunity for corrective action. However, the concepts of clinical significance and opportunity are difficult to define in automated systems, and effectiveness of alerting algorithms is difficult to measure. This paper describes recent efforts on the Simon project to capture information from ICU care providers about patient state and therapy in response to alerts, in order to assess the value of event definitions and progressively refine alerting algorithms. Event definitions for intracranial pressure and cerebral perfusion pressure were studied by implementing a reliable system to automatically deliver alerts to clinical users’ alphanumeric pagers, and to capture associated documentation about patient state and therapy when the alerts occurred. During a 6-month test period in the trauma ICU at Vanderbilt University Medical Center, 530 alerts were detected in 2280 hours of data spanning 14 patients. Clinical users electronically documented 81% of these alerts as they occurred. Retrospectively classifying documentation based on therapeutic actions taken, or reasons why actions were not taken, provided useful information about ways to potentially improve event definitions and enhance system utility.
Campmans, Zizi; van Rhijn, Arianne; Dull, René M.; Santen-Reestman, Jacqueline; Taxis, Katja
2018-01-01
Introduction Drug confusion is thought to be the most common type of dispensing error. Several strategies can be implemented to reduce the risk of medication errors. One of these are alerts in the pharmacy information system. Objective To evaluate the experiences of pharmacists and pharmacy technicians with alerts for drug name and strength confusion. Methods In May 2017, a cross-sectional survey of pharmacists and pharmacy technicians was performed in community pharmacies in the Netherlands using an online questionnaire. Results Of the 269 respondents, 86% (n = 230) had noticed the alert for drug name confusion, and 26% (n = 67) for drug strength confusion. Of those 230, 9% (n = 20) had experienced that the alert had prevented dispensing the wrong drug. For drug strength confusion, this proportion was 12% (n = 8). Respondents preferred to have an alert for drug name and strength confusion in the pharmacy information system. ‘Alert fatigue’ was an important issue, so alerts should only be introduced for frequent confusions or confusions with serious consequences. Conclusion Pharmacists and pharmacy technicians were positive about having alerts for drug confusions in their pharmacy information system and experienced that alerts contributed to the prevention of dispensing errors. To prevent alert fatigue, it was considered important not to include all possible confusions as a new alert: the potential contribution to the prevention of drug confusion should be weighed against the risk of alert fatigue. PMID:29813099
33 CFR 101.310 - Additional communication devices.
Code of Federal Regulations, 2010 CFR
2010-07-01
... communication devices. (a) Alert Systems. Alert systems, such as the ship security alert system required in... part 104, 105, or 106 of this subchapter. (b) Automated Identification Systems (AIS). AIS may be used... plan under part 104 of this subchapter. See 33 CFR part 164 for additional information on AIS device...
33 CFR 101.310 - Additional communication devices.
Code of Federal Regulations, 2014 CFR
2014-07-01
... communication devices. (a) Alert Systems. Alert systems, such as the ship security alert system required in... part 104, 105, or 106 of this subchapter. (b) Automated Identification Systems (AIS). AIS may be used... plan under part 104 of this subchapter. See 33 CFR part 164 for additional information on AIS device...
33 CFR 101.310 - Additional communication devices.
Code of Federal Regulations, 2012 CFR
2012-07-01
... communication devices. (a) Alert Systems. Alert systems, such as the ship security alert system required in... part 104, 105, or 106 of this subchapter. (b) Automated Identification Systems (AIS). AIS may be used... plan under part 104 of this subchapter. See 33 CFR part 164 for additional information on AIS device...
33 CFR 101.310 - Additional communication devices.
Code of Federal Regulations, 2011 CFR
2011-07-01
... communication devices. (a) Alert Systems. Alert systems, such as the ship security alert system required in... part 104, 105, or 106 of this subchapter. (b) Automated Identification Systems (AIS). AIS may be used... plan under part 104 of this subchapter. See 33 CFR part 164 for additional information on AIS device...
33 CFR 101.310 - Additional communication devices.
Code of Federal Regulations, 2013 CFR
2013-07-01
... communication devices. (a) Alert Systems. Alert systems, such as the ship security alert system required in... part 104, 105, or 106 of this subchapter. (b) Automated Identification Systems (AIS). AIS may be used... plan under part 104 of this subchapter. See 33 CFR part 164 for additional information on AIS device...
Multiwavelength observations of nova SMCN 2016-10a - one of the brightest novae ever observed
NASA Astrophysics Data System (ADS)
Aydi, E.; Page, K. L.; Kuin, N. P. M.; Darnley, M. J.; Walter, F. M.; Mróz, P.; Buckley, D. A. H.; Mohamed, S.; Whitelock, P.; Woudt, P.; Williams, S. C.; Orio, M.; Williams, R. E.; Beardmore, A. P.; Osborne, J. P.; Kniazev, A.; Ribeiro, V. A. R. M.; Udalski, A.; Strader, J.; Chomiuk, L.
2018-02-01
We report on multiwavelength observations of nova Small Magellanic Cloud Nova 2016-10a. The present observational set is one of the most comprehensive for any nova in the Small Magellanic Cloud, including low-, medium-, and high-resolution optical spectroscopy and spectropolarimetry from Southern African Large Telescope, Folded Low-Order Yte-Pupil Double-Dispersed Spectrograph, and Southern Astrophysical Research; long-term Optical Gravitational Lensing Experiment V- and I-bands photometry dating back to 6 yr before eruption; Small and Moderate Aperture Research Telescope System optical and near-IR photometry from ˜11 d until over 280 d post-eruption; Swift satellite X-ray and ultraviolet observations from ˜6 d until 319 d post-eruption. The progenitor system contains a bright disc and a main sequence or a sub-giant secondary. The nova is very fast with t2 ≃ 4.0 ± 1.0 d and t3 ≃ 7.8 ± 2.0 d in the V band. If the nova is in the SMC, at a distance of ˜61 ± 10 kpc, we derive MV, max ≃ -10.5 ± 0.5, making it the brightest nova ever discovered in the SMC and one of the brightest on record. At day 5 post-eruption the spectral lines show a He/N spectroscopic class and an Full Width at Half Maximum of ˜3500 km s-1, indicating moderately high ejection velocities. The nova entered the nebular phase ˜20 d post-eruption, predicting the imminent super-soft source turn-on in the X-rays, which started ˜28 d post-eruption. The super-soft source properties indicate a white dwarf mass between 1.2 and 1.3 M⊙ in good agreement with the optical conclusions.
NASA Technical Reports Server (NTRS)
Lee, Seung Man; Park, Chunki; Cone, Andrew Clayton; Thipphavong, David P.; Santiago, Confesor
2016-01-01
This presentation contains the analysis results of NAS-wide fast-time simulations with UAS and VFR traffic for a single day for evaluating the performance of Detect-and-Avoid (DAA) alerting and guidance systems. This purpose of this study was to help refine and validate MOPS alerting and guidance requirements. In this study, we generated plots of all performance metrics that are specified by RTCA SC-228 Minimum Operational Performance Standards (MOPS): 1) to evaluate the sensitivity of alerting parameters on the performance metrics of each DAA alert type: Preventive, Corrective, and Warning alerts and 2) to evaluate the effect of sensor uncertainty on DAA alerting and guidance performance.
Can isolated single black holes produce X-ray novae?
NASA Astrophysics Data System (ADS)
Matsumoto, Tatsuya; Teraki, Yuto; Ioka, Kunihito
2018-03-01
Almost all black holes (BHs) and BH candidates in our Galaxy have been discovered as soft X-ray transients, so-called X-ray novae. X-ray novae are usually considered to arise from binary systems. Here, we propose that X-ray novae are also caused by isolated single BHs. We calculate the distribution of the accretion rate from interstellar matter to isolated BHs, and find that BHs in molecular clouds satisfy the condition of the hydrogen-ionization disc instability, which results in X-ray novae. The estimated event rate is consistent with the observed one. We also check an X-ray novae catalogue (Corral-Santana et al.) and find that 16/59 ˜ 0.27 of the observed X-ray novae are potentially powered by isolated BHs. The possible candidates include IGR J17454-2919, XTE J1908-094, and SAX J1711.6-3808. Near-infrared photometric and spectroscopic follow-ups can exclude companion stars for a BH census in our Galaxy.
Detecting Nova Shells around known Cataclysmic Variable systems
NASA Astrophysics Data System (ADS)
Xhakaj, Enia; Kupfer, Thomas; Prince, Thomas A.
2017-01-01
Nova shells are hydrogen-rich nebulae around Cataclysmic Variables that are created when a Nova outburst takes place. Learning more about Nova shells can help us get a better understanding of the long-term evolution of white dwarfs in active Cataclysmic Variables. In this project, we present the search for Nova shells around 1700 Cataclysmic Variables, using Hα images from the Palomar Transient Factory (PTF) survey. The PTF Hα survey started in 2009 using the 48’’ Oschin telescope at Palomar Observatory and is the first of its type covering the whole northern hemisphere while reaching 18 mags in 60 seconds of exposure. We concentrated our search on the IAU catalogue of Historical Novae, as well as on the SDSS and the Ritter-Kolb catalogue of Cataclysmic Variables. We numerically analyzed radial profiles centered on the target sources to search for excess emission potentially associated with the shells. Out of 1700 Cataclysmic Variables present in these catalogues, we detected 25 Nova shells, out of which 20 are not observed before.
Olivier Chesneau's Work on Novae
NASA Astrophysics Data System (ADS)
Millour, F.; Lagadec, E.
2015-12-01
Olivier Chesneau founded a brand new field of observational astrophysics with his attempts to resolve the novae expanding fireball from the very first days of the explosion. With the images he could get, he showed that novae do indeed explode in an aspherical way, leading to a change of paradigm for the physics of these yet-poorly understood catastrophic systems. He also set the stage for a new way of estimating novae distances, by directly measuring the sky-size of the fireball and comparing it with spectroscopic scales, taking into account the tremendous effects of the fireball geometry.
Microstructures of Rare Silicate Stardust from Nova and Supernovae
NASA Technical Reports Server (NTRS)
Nguyen, A. N.; Keller, L. P.; Rahman, Z.; Messenger, S
2011-01-01
Most silicate stardust analyzed in the laboratory and observed around stellar environments derives from O-rich red giant and AGB stars [1,2]. Supernova (SN) silicates and oxides are comparatively rare, and fewer than 10 grains from no-va or binary star systems have been identified to date. Very little is known about dust formation in these stellar environments. Mineralogical studies of only three O-rich SN [3-5] and no nova grains have been performed. Here we report the microstructure and chemical makeup of two SN silicates and one nova grain.
Developing an Early-Alert System to Promote Student Visits to Tutor Center
ERIC Educational Resources Information Center
Cai, Qijie; Lewis, Carrie L.; Higdon, Jude
2015-01-01
An early-alert system (MavCLASS) was developed and piloted in a large gateway math class with 611 freshman students to identify academically at-risk students and provide alert messages. It was found that there was significant association between the alert messages students received and their visits to the university's tutor center. Further, the…
Real-time alerts and reminders using information systems.
Wanderer, Jonathan P; Sandberg, Warren S; Ehrenfeld, Jesse M
2011-09-01
Adoption of information systems throughout the hospital environment has enabled the development of real-time physiologic alerts and clinician reminder systems. These clinical tools can be made available through the deployment of anesthesia information management systems (AIMS). Creating usable alert systems requires understanding of technical considerations. Various successful implementations are reviewed, encompassing cost reduction, improved revenue capture, timely antibiotic administration, and postoperative nausea and vomiting prophylaxis. Challenges to the widespread use of real-time alerts and reminders include AIMS adoption rates and the difficulty in choosing appropriate areas and approaches for information systems support. Copyright © 2011 Elsevier Inc. All rights reserved.
X-ray Novae and Related Systems
NASA Technical Reports Server (NTRS)
Wheeler, J. Craig; Kim, Soonwook; Mineshige, Shin
1992-01-01
Accretion disk thermal instability models have been successful in accounting for the basic observations of dwarf novae and the steady behavior of nova-like systems. Models for the dwarf-nova like variability of the old nova and intermediate polar GK Per give good agreement with the burst amplitude, profile and recurrence time in the optical and UV. A month-long 'precursor plateau' in the UV is predicted for the expected 1992 outburst prior to the rise to maximum in the optical and UV. The models for the time scales of the outbursts and corresponding UV spectra at maximum are consistent with the inner edge of the accretion disk being essentially constant between quiescence and outburst and a factor of four larger than the co-rotation radius. These conclusions represent a challenge to the standard theory of magnetic accretion. Disk instability models have also given a good representation of the soft X-ray and optical outbursts of the X-ray novae A0620-00 and GS2000+25. Formation of coronae above the disk, heated by magneto-acoustic flux from the disk, may account for the temporal and spectral properties of the hard X-ray and gamma ray emission of related sources such as Cyg X-1, GS 2023+33 (V404 Cyg), IE 1740.7-2942 (the 'Galactic Center' Einstein Source), and GS 1124-683 (Nova Muscae).
Källhammer, Jan-Erik; Smith, Kip
2012-08-01
We investigated five contextual variables that we hypothesized would influence driver acceptance of alerts to pedestrians issued by a night vision active safety system to inform the specification of the system's alerting strategies. Driver acceptance of automotive active safety systems is a key factor to promote their use and implies a need to assess factors influencing driver acceptance. In a field operational test, 10 drivers drove instrumented vehicles equipped with a preproduction night vision system with pedestrian detection software. In a follow-up experiment, the 10 drivers and 25 additional volunteers without experience with the system watched 57 clips with pedestrian encounters gathered during the field operational test. They rated the acceptance of an alert to each pedestrian encounter. Levels of rating concordance were significant between drivers who experienced the encounters and participants who did not. Two contextual variables, pedestrian location and motion, were found to influence ratings. Alerts were more accepted when pedestrians were close to or moving toward the vehicle's path. The study demonstrates the utility of using subjective driver acceptance ratings to inform the design of active safety systems and to leverage expensive field operational test data within the confines of the laboratory. The design of alerting strategies for active safety systems needs to heed the driver's contextual sensitivity to issued alerts.
21 CFR 26.50 - Alert system and exchange of postmarket vigilance reports.
Code of Federal Regulations, 2010 CFR
2010-04-01
... QUALITY SYSTEM AUDIT REPORTS, AND CERTAIN MEDICAL DEVICE PRODUCT EVALUATION REPORTS: UNITED STATES AND THE EUROPEAN COMMUNITY Specific Sector Provisions for Medical Devices § 26.50 Alert system and exchange of... 21 Food and Drugs 1 2010-04-01 2010-04-01 false Alert system and exchange of postmarket vigilance...
NASA Astrophysics Data System (ADS)
Shara, Michael M.; Drissen, Laurent; Martin, Thomas; Alarie, Alexandre; Stephenson, F. Richard
2017-02-01
The Z Cam-type dwarf nova AT Cancri (AT Cnc) displays a classical nova (CN) shell, demonstrating that mass transfer in cataclysmic binaries decreases substantially after a CN eruption. The hibernation scenario of cataclysmic binaries predicts such a decrease, on a time-scale of a few centuries. In order to measure the time since AT Cnc's last CN eruption, we have measured the radial velocities of a hundred clumps in its ejecta with SITELLE, Canada-France-Hawaii Telescope's recently commissioned imaging Fourier transform spectrometer. These range from -455 to +490 km s-1. Coupled with the known distance to AT Cnc of 460 pc, the size of AT Cnc's shell, and a simple model of nova ejecta deceleration, we determine that the last CN eruption of this system occurred 330_{-90}^{+135} yr ago. This is the most rapid transition from a high mass-transfer rate, nova-like variable to a low mass-transfer rate, dwarf nova yet measured, and in accord with the hibernation scenario of cataclysmic binaries. We conclude by noting the similarity in the deduced outburst date (within a century of 1686 CE) of AT Cnc to a `guest star' reported in the constellation Cancer by Korean observers in 1645 CE.
Comparative analytics of infusion pump data across multiple hospital systems.
Catlin, Ann Christine; Malloy, William X; Arthur, Karen J; Gaston, Cindy; Young, James; Fernando, Sudheera; Fernando, Ruchith
2015-02-15
A Web-based analytics system for conducting inhouse evaluations and cross-facility comparisons of alert data generated by smart infusion pumps is described. The Infusion Pump Informatics (IPI) project, a collaborative effort led by research scientists at Purdue University, was launched in 2009 to provide advanced analytics and tools for workflow analyses to assist hospitals in determining the significance of smart-pump alerts and reducing nuisance alerts. The IPI system allows facility-specific analyses of alert patterns and trends, as well as cross-facility comparisons of alert data uploaded by more than 55 participating institutions using different types of smart pumps. Tools accessible through the IPI portal include (1) charts displaying aggregated or breakout data on the top drugs associated with alerts, numbers of alerts per device or care area, and override-to-alert ratios, (2) investigative reports that can be used to characterize and analyze pump-programming errors in a variety of ways (e.g., by drug, by infusion type, by time of day), and (3) "drill-down" workflow analytics enabling users to evaluate alert patterns—both internally and in relation to patterns at other hospitals—in a quick and efficient stepwise fashion. The formation of the IPI analytics system to support a community of hospitals has been successful in providing sophisticated tools for member facilities to review, investigate, and efficiently analyze smart-pump alert data, not only within a member facility but also across other member facilities, to further enhance smart pump drug library design. Copyright © 2015 by the American Society of Health-System Pharmacists, Inc. All rights reserved.
[Detection of Brucella with an automatic hemoculture system: Bact/Alert].
Casas, J; Partal, Y; Llosá, J; Leiva, J; Navarro, J M; de la Rosa, M
1994-12-01
The ability of in vitro and in vivo detection of Brucella spp. with the Bact/Alert system was studied. Three strains of Brucella melitensis and two of Brucella abortus were used. Different dilutions of the five strains were performed in trypticase soy broth (TSB), achieving concentrations of 1 cfu/ml, 5 cfu/ml, 10 cfu/ml and 100 cfu/ml. Ten ml of each dilution and strain were inoculated into 5 aerobic bottles Bact/Alert and 5 biphasic Hemóline bottles. Furthermore, over a 9 month period, 8,216 bottles of Bact/Alert bottles from hospitalized patients and from the emergency department were processed in the authors' laboratory. The mean detection time for Brucella growth was from 2 to 3 days with the Bact/Alert system, and 14 days in the biphasic bottles. Former bottles processed in the authors' laboratory, 11 aerobic bottles belonged to 5 patients in whom brucelosis was confirmed by bloodculture. The Bact/Alert system detected Brucella melitensis in only on bottle at 2.9 days of incubation. In 7 bottles Bact/Alert detected B. melitensis by a blind pass of these bottles at 10 to 20 days of incubation. These results suggest that the Bact/Alert system does not totally solve the diagnosis of brucellosis. Blind passes of the bloodcultures are required.
The Evolution of NR TrA (Nova TrA 2008) from 2008 through 2017
NASA Astrophysics Data System (ADS)
Walter, Frederick M.; Burwitz, Vadim; Kafka, Stella
2018-06-01
The classical nova NR TrA was discovered as an O-type optically-thick classical nova. There is no evidence that it formed dust. Within four years the envelope became sufficiently thin to reveal an eclipsing accretion disk-dominated system with orbitally-modulated permitted lines of C IV, N V, and O VI. XMM observations reveal a non-eclipsing soft X-ray source and a deeply-eclipsing UV continuum. We will present the first ten years of optical spectral evolution of this system accompanied by ten years of BVRIJHK photometry, with an eye to deciphering the current nature of the system.
Restablished Accretion in Post-outburst Classical Novae Revealed by X-rays
NASA Astrophysics Data System (ADS)
Hernanz, Margarita; Ferri, Carlo; Sala, Glòria
2009-05-01
Classical novae are explosions on accreting white dwarfs (hereinafter WDs) in cataclysmic variables (hereinafter CVs) a hydrogen thermonuclear runaway on top of the WD is responsible for the outburst. X-rays provide a unique way to study the turn-off of H-burning, because super soft X-rays reveal the hot WD photosphere, but also to understand how accretion is established again in the binary system. Observations with XMM-Newton of some post-outburst novae have revealed such a process, but a coverage up to larger energies -as Simbol-X will provide- is fundamental to well understand the characteristics of the binary system and of the nova ejecta. We present a brief summary of our results up to now and prospects for the Simbol-X mission.
78 FR 16806 - The Commercial Mobile Alert System
Federal Register 2010, 2011, 2012, 2013, 2014
2013-03-19
... FEDERAL COMMUNICATIONS COMMISSION 47 CFR Part 10 [PS Docket No. 07-287; DA 13-280] The Commercial Mobile Alert System AGENCY: Federal Communications Commission. ACTION: Final rule. SUMMARY: In this document, the Commission amends its rules to change the name of the Commercial Mobile Alert System (CMAS...
47 CFR 10.300 - Alert aggregator. [Reserved
Code of Federal Regulations, 2013 CFR
2013-10-01
... 47 Telecommunication 1 2013-10-01 2013-10-01 false Alert aggregator. [Reserved] 10.300 Section 10.300 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL WIRELESS EMERGENCY ALERTS System Architecture § 10.300 Alert aggregator. [Reserved] ...
47 CFR 10.300 - Alert aggregator. [Reserved
Code of Federal Regulations, 2014 CFR
2014-10-01
... 47 Telecommunication 1 2014-10-01 2014-10-01 false Alert aggregator. [Reserved] 10.300 Section 10.300 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL WIRELESS EMERGENCY ALERTS System Architecture § 10.300 Alert aggregator. [Reserved] ...
Closing the loop in ICU decision support: physiologic event detection, alerts, and documentation.
Norris, P. R.; Dawant, B. M.
2001-01-01
Automated physiologic event detection and alerting is a challenging task in the ICU. Ideally care providers should be alerted only when events are clinically significant and there is opportunity for corrective action. However, the concepts of clinical significance and opportunity are difficult to define in automated systems, and effectiveness of alerting algorithms is difficult to measure. This paper describes recent efforts on the Simon project to capture information from ICU care providers about patient state and therapy in response to alerts, in order to assess the value of event definitions and progressively refine alerting algorithms. Event definitions for intracranial pressure and cerebral perfusion pressure were studied by implementing a reliable system to automatically deliver alerts to clinical users alphanumeric pagers, and to capture associated documentation about patient state and therapy when the alerts occurred. During a 6-month test period in the trauma ICU at Vanderbilt University Medical Center, 530 alerts were detected in 2280 hours of data spanning 14 patients. Clinical users electronically documented 81% of these alerts as they occurred. Retrospectively classifying documentation based on therapeutic actions taken, or reasons why actions were not taken, provided useful information about ways to potentially improve event definitions and enhance system utility. PMID:11825238
Lessons from Hawaii: A Blessing in Disguise.
Deitchman, Scott; Dallas, Cham E; Burkle, Frederick
2018-03-20
On January 13, 2018, Hawaii experienced an erroneous alert that falsely warned of an imminent ballistic missile strike. Rather than focus on the inconvenience caused by the false alert, we used reporting of the event to identify the missing elements that would characterize a system that could save lives by alerting and informing the public in a nuclear detonation. These include warnings that contain essential information rather than directing recipients to secondary sources; a system that issues alerts directly from federal agencies that will have the earliest warning; a robust multimodal alerting system that can deliver messages before and after the detonation; and swift activation of federal agencies immediately upon warning.
Alert generation and cockpit presentation for an integrated microburst alerting system
NASA Technical Reports Server (NTRS)
Wanke, Craig; Hansman, R. John, Jr.
1991-01-01
Alert generation and cockpit presentation issues for low level wind shear (microburst) alerts are investigated. Alert generation issues center on the development of a hazard criterion which allows integration of both ground based and airborne wind shear detection systems to form an accurate picture of the aviation hazard posed by a particular wind shear situation. A methodology for the testing of a hazard criteria through flight simulation has been developed, and has been used to examine the effectiveness and feasibility of several possible criteria. Also, an experiment to evaluate candidate graphical cockpit displays for microburst alerts using a piloted simulator has been designed.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-10-03
... Committee 147, Minimum Operational Performance Standards for Traffic Alert and Collision Avoidance Systems... Traffic Alert and Collision Avoidance Systems Airborne Equipment. SUMMARY: The FAA is issuing this notice... Performance Standards for Traffic Alert and Collision Avoidance Systems Airborne Equipment. DATES: The meeting...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-11-05
... Committee 147, Minimum Operational Performance Standards for Traffic Alert and Collision Avoidance Systems... Traffic Alert and Collision Avoidance Systems Airborne Equipment. SUMMARY: The FAA is issuing this notice... Performance Standards for Traffic Alert and Collision Avoidance Systems Airborne Equipment. DATES: The meeting...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-05-18
... 147, Minimal Operations Performance Standards for Traffic Alert and Collision Avoidance Systems... Traffic Alert and Collision Avoidance Systems Airborne Equipment. SUMMARY: The FAA is issuing this notice... Performance Standards for Traffic Alert and Collision Avoidance Systems Airborne Equipment. DATES: The meeting...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-01-30
... Committee 147, Minimum Operational Performance Standards for Traffic Alert and Collision Avoidance Systems... Traffic Alert and Collision Avoidance Systems Airborne Equipment. SUMMARY: The FAA is issuing this notice... Performance Standards for Traffic Alert and Collision Avoidance Systems Airborne Equipment. DATES: The meeting...
1984-12-01
AD-RI59 367 STATISTICS FROM THE OPERATION OF THE LOW-LEVEL WIND I/i SHEAR ALERT SYSTEM (L..(U) NATIONAL CENTER FOR ATOMSPHERIC RESEARCH BOULDER CO...NATIONAL BUREAU OF STANDARDS-1963A % % Oh b DOT/FAAIPM-84132 Statistics from the Operation of the Program Engineering Low-Level Wind Shear Alert System and...The Operation of The Low-Level Wind December 1984 Shear Alert System (LLWAS) During The JAWS Project: 6. Performing Organization Code An Interim Report
Reaching out to clinicians: implementation of a computerized alert system.
Degnan, Dan; Merryfield, Dave; Hultgren, Steve
2004-01-01
Several published articles have identified that providing automated, computer-generated clinical alerts about potentially critical clinical situations should result in better quality of care. In 1999, the pharmacy department at a community hospital network implemented and refined a commercially available, computerized clinical alert system. This case report discusses the implementation process, gives examples of how the system is used, and describes results following implementation. The use of the clinical alert system in this hospital network resulted in improved patient safety as well as in greater efficiency and decreased costs.
Modeling, Analyzing, and Mitigating Dissonance Between Alerting Systems
NASA Technical Reports Server (NTRS)
Song, Lixia; Kuchar, James K.
2003-01-01
Alerting systems are becoming pervasive in process operations, which may result in the potential for dissonance or conflict in information from different alerting systems that suggests different threat levels and/or actions to resolve hazards. Little is currently available to help in predicting or solving the dissonance problem. This thesis presents a methodology to model and analyze dissonance between alerting systems, providing both a theoretical foundation for understanding dissonance and a practical basis from which specific problems can be addressed. A state-space representation of multiple alerting system operation is generalized that can be tailored across a variety of applications. Based on the representation, two major causes of dissonance are identified: logic differences and sensor error. Additionally, several possible types of dissonance are identified. A mathematical analysis method is developed to identify the conditions for dissonance originating from logic differences. A probabilistic analysis methodology is developed to estimate the probability of dissonance originating from sensor error, and to compare the relative contribution to dissonance of sensor error against the contribution from logic differences. A hybrid model, which describes the dynamic behavior of the process with multiple alerting systems, is developed to identify dangerous dissonance space, from which the process can lead to disaster. Methodologies to avoid or mitigate dissonance are outlined. Two examples are used to demonstrate the application of the methodology. First, a conceptual In-Trail Spacing example is presented. The methodology is applied to identify the conditions for possible dissonance, to identify relative contribution of logic difference and sensor error, and to identify dangerous dissonance space. Several proposed mitigation methods are demonstrated in this example. In the second example, the methodology is applied to address the dissonance problem between two air traffic alert and avoidance systems: the existing Traffic Alert and Collision Avoidance System (TCAS) vs. the proposed Airborne Conflict Management system (ACM). Conditions on ACM resolution maneuvers are identified to avoid dynamic dissonance between TCAS and ACM. Also included in this report is an Appendix written by Lee Winder about recent and continuing work on alerting systems design. The application of Markov Decision Process (MDP) theory to complex alerting problems is discussed and illustrated with an abstract example system.
ERIC Educational Resources Information Center
deVille, Barry, Ed.
This is a preliminary examination of the present status and future prospects of educational technology in Nova Scotian schools. It is aimed at developing a plan to enhance the quality of educational technology by concentrating on systems which will be conducive to realizing educational goals at a reasonable cost. An overview of the institutional…
NASA Astrophysics Data System (ADS)
King, Lionel Bradley
This dissertation investigates local attempts to use technology as a force for regional rehabilitation in the economically-depressed Maritime region of Canada. At the time of Confederation in 1867, the Maritime province of Nova Scotia was prosperous, progressive, and cultured. By the end of the 1910s, the province had entered a long period of economic and social decline. Recent historiography has shown that, far from passively accepting their fate, Nova Scotians and other Maritimers, actively resisted marginalization with political, cultural, or social action. The thesis expands upon that literature by exploring technology-based strategies of provincial rehabilitation using Thomas P. Hughes's systems perspective and David E. Nye's semiotic approach. In doing so, it applies methods from the social constructivist school of the history of technology to the larger concerns of Maritime Canadian historiography. In large part, the North American culture of technology determined the ways in which Nova Scotians applied technological solutions to provincial concerns. Technology has long been central to the Western idea of progress. As the "high technology" of the late nineteenth and early twentieth centuries, electricity reinforced that view: its ephemeral nature and silent efficiency led people to endow it with transformative, even mystical, powers. As a result, Nova Scotians, adopted a program of electrical modernization in the late 1910s as a remedy for regional disparity. The Nova Scotia government's first step was the creation of an Ontario-style hydroelectric commission designed to bring order to the province's fragmented and inefficient electrical network. Over the next few decades, the Nova Scotia Power Commission implemented rural electrification, home modernization, and regional system-building models that had already proven successful in Ontario and the United States. The system-building philosophies behind these programs were adapted to local conditions and disseminated throughout the province by politicians, engineers, businesspeople, and social reformers. Although electrical modernization failed to address the structural reasons for the province's decline, Nova Scotians continued to include it in their provincial rehabilitation plans until the 1960s. In sum, the electrification of Nova Scotia was not merely a technical event, but was shaped by the province's aspiration to regain its prior position in Confederation.
NASA Astrophysics Data System (ADS)
Pojmański, G.
2004-10-01
The All Sky Automated Survey is a low cost project, the ultimate goal of which is detection and investigation of any kind of the photometric variability present all over the sky. The current system consists of 4 instruments covering 36x36, 9x9 (2 units) and 2x2 degrees, equipped with 2Kx2K CCDs, V,R,I standard filters and custom made automated mounts. All are working in Las Campanas Observatory, Chile in fully automated mode. In the ASAS-3 phase of the project we have been taking data at a rate of 1 measurement per 1-3 days for all available objects brighter than V=14, located south of δ=+28 deg. So far over 2 TB of images has been collected and analyzed, leading to a photometric light curve catalog of over 10 million sources. A preliminary search for variability revealed over 40,000 bright, variable sources (over 75 % were not previously known). Direct access to the data is available over the Internet: http://www.astrouw.edu.pl/˜ gp/asas. At present the ASAS Alert System is being tested. Events, like outbursts of CV's or Novae, eclipses etc. are reported within a few minutes after first detection. Due to large number of artifacts in these data raw events require verification, which can take up to 24 hours.
Given, Douglas D.; Cochran, Elizabeth S.; Heaton, Thomas; Hauksson, Egill; Allen, Richard; Hellweg, Peggy; Vidale, John; Bodin, Paul
2014-01-01
Earthquake Early Warning (EEW) systems can provide as much as tens of seconds of warning to people and automated systems before strong shaking arrives. The United States Geological Survey (USGS) and its partners are developing such an EEW system, called ShakeAlert, for the West Coast of the United States. This document describes the technical implementation of that system, which leverages existing stations and infrastructure of the Advanced National Seismic System (ANSS) regional networks to achieve this new capability. While significant progress has been made in developing the ShakeAlert early warning system, improved robustness of each component of the system and additional testing and certification are needed for the system to be reliable enough to issue public alerts. Major components of the system include dense networks of ground motion sensors, telecommunications from those sensors to central processing systems, algorithms for event detection and alert creation, and distribution systems to alert users. Capital investment costs for a West Coast EEW system are projected to be $38.3M, with additional annual maintenance and operations totaling $16.1M—in addition to current ANSS expenditures for earthquake monitoring. An EEW system is complementary to, but does not replace, other strategies to mitigate earthquake losses. The system has limitations: false and missed alerts are possible, and the area very near to an earthquake epicenter may receive little or no warning. However, such an EEW system would save lives, reduce injuries and damage, and improve community resilience by reducing longer-term economic losses for both public and private entities.
McDaniel, Robert B; Burlison, Jonathan D; Baker, Donald K; Hasan, Murad; Robertson, Jennifer; Hartford, Christine; Howard, Scott C; Sablauer, Andras
2016-01-01
Metrics for evaluating interruptive prescribing alerts have many limitations. Additional methods are needed to identify opportunities to improve alerting systems and prevent alert fatigue. In this study, the authors determined whether alert dwell time—the time elapsed from when an interruptive alert is generated to when it is dismissed—could be calculated by using historical alert data from log files. Drug–drug interaction (DDI) alerts from 3 years of electronic health record data were queried. Alert dwell time was calculated for 25,965 alerts, including 777 unique DDIs. The median alert dwell time was 8 s (range, 1–4913 s). Resident physicians had longer median alert dwell times than other prescribers (P < .001). The 10 most frequent DDI alerts (n = 8759 alerts) had shorter median dwell times than alerts that only occurred once (P < .001). This metric can be used in future research to evaluate the effectiveness and efficiency of interruptive prescribing alerts. PMID:26499101
Character Sets for PLATO/NovaNET: An Expository Catalog.
ERIC Educational Resources Information Center
Gilpin, John B.
The PLATO and NovaNET computer-based instructional systems use a fixed system character set ("normal font") and an author-definable character set ("alternate font"). The alternate font lets the author construct his own symbols and bitmapped pictures. This expository catalog allows users to determine quickly (1) whether there is…
Development of an "Alert Framework" Based on the Practices in the Medical Front.
Sakata, Takuya; Araki, Kenji; Yamazaki, Tomoyoshi; Kawano, Koichi; Maeda, Minoru; Kushima, Muneo; Araki, Sanae
2018-05-09
At the University of Miyazaki Hospital (UMH), we have accumulated and semantically structured a vast amount of medical information since the activation of the electronic health record system approximately 10 years ago. With this medical information, we have decided to develop an alert system for aiding in medical treatment. The purpose of this investigation is to not only to integrate an alert framework into the electronic heath record system, but also to formulate a modeling method of this knowledge. A trial alert framework was developed for the staff in various occupational categories at the UMH. Based on findings of subsequent interviews, a more detailed and upgraded alert framework was constructed, resulting in the final model. Based on our current findings, an alert framework was developed with four major items. Based on the analysis of the medical practices from the trial model, it has been concluded that there are four major risk patterns that trigger the alert. Furthermore, the current alert framework contains detailed definitions which are easily substituted into the database, leading to easy implementation of the electronic health records.
Auditory alert systems with enhanced detectability
NASA Technical Reports Server (NTRS)
Begault, Durand R. (Inventor)
2008-01-01
Methods and systems for distinguishing an auditory alert signal from a background of one or more non-alert signals. In a first embodiment, a prefix signal, associated with an existing alert signal, is provided that has a signal component in each of three or more selected frequency ranges, with each signal component in each of three or more selected level at least 3-10 dB above an estimated background (non-alert) level in that frequency range. The alert signal may be chirped within one or more frequency bands. In another embodiment, an alert signal moves, continuously or discontinuously, from one location to another over a short time interval, introducing a perceived spatial modulation or jitter. In another embodiment, a weighted sum of background signals adjacent to each ear is formed, and the weighted sum is delivered to each ear as a uniform background; a distinguishable alert signal is presented on top of this weighted sum signal at one ear, or distinguishable first and second alert signals are presented at two ears of a subject.
47 CFR 10.310 - Federal alert gateway. [Reserved
Code of Federal Regulations, 2013 CFR
2013-10-01
... 47 Telecommunication 1 2013-10-01 2013-10-01 false Federal alert gateway. [Reserved] 10.310 Section 10.310 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL WIRELESS EMERGENCY ALERTS System Architecture § 10.310 Federal alert gateway. [Reserved] ...
47 CFR 10.310 - Federal alert gateway. [Reserved
Code of Federal Regulations, 2014 CFR
2014-10-01
... 47 Telecommunication 1 2014-10-01 2014-10-01 false Federal alert gateway. [Reserved] 10.310 Section 10.310 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL WIRELESS EMERGENCY ALERTS System Architecture § 10.310 Federal alert gateway. [Reserved] ...
Alerts Visualization and Clustering in Network-based Intrusion Detection
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yang, Dr. Li; Gasior, Wade C; Dasireddy, Swetha
2010-04-01
Today's Intrusion detection systems when deployed on a busy network overload the network with huge number of alerts. This behavior of producing too much raw information makes it less effective. We propose a system which takes both raw data and Snort alerts to visualize and analyze possible intrusions in a network. Then we present with two models for the visualization of clustered alerts. Our first model gives the network administrator with the logical topology of the network and detailed information of each node that involves its associated alerts and connections. In the second model, flocking model, presents the network administratormore » with the visual representation of IDS data in which each alert is represented in different color and the alerts with maximum similarity move together. This gives network administrator with the idea of detecting various of intrusions through visualizing the alert patterns.« less
NASA Astrophysics Data System (ADS)
Souvatzoglou, G.; Papaioannou, A.; Mavromichalaki, H.; Dimitroulakos, J.; Sarlanis, C.
2014-11-01
Whenever a significant intensity increase is being recorded by at least three neutron monitor stations in real-time mode, a ground level enhancement (GLE) event is marked and an automated alert is issued. Although, the physical concept of the algorithm is solid and has efficiently worked in a number of cases, the availability of real-time data is still an open issue and makes timely GLE alerts quite challenging. In this work we present the optimization of the GLE alert that has been set into operation since 2006 at the Athens Neutron Monitor Station. This upgrade has led to GLE Alert Plus, which is currently based upon the Neutron Monitor Database (NMDB). We have determined the critical values per station allowing us to issue reliable GLE alerts close to the initiation of the event while at the same time we keep the false alert rate at low levels. Furthermore, we have managed to treat the problem of data availability, introducing the Go-Back-N algorithm. A total of 13 GLE events have been marked from January 2000 to December 2012. GLE Alert Plus issued an alert for 12 events. These alert times are compared to the alert times of GOES Space Weather Prediction Center and Solar Energetic Particle forecaster of the University of Málaga (UMASEP). In all cases GLE Alert Plus precedes the GOES alert by ≈8-52 min. The comparison with UMASEP demonstrated a remarkably good agreement. Real-time GLE alerts by GLE Alert Plus may be retrieved by http://cosray.phys.uoa.gr/gle_alert_plus.html, http://www.nmdb.eu, and http://swe.ssa.esa.int/web/guest/space-radiation. An automated GLE alert email notification system is also available to interested users.
McDonald, C P; Rogers, A; Cox, M; Smith, R; Roy, A; Robbins, S; Hartley, S; Barbara, J A J; Rothenberg, S; Stutzman, L; Widders, G
2002-10-01
Bacterial transmission remains the major component of morbidity and mortality associated with transfusion-transmitted infections. Platelet concentrates are the most common cause of bacterial transmission. The BacT/ALERT 3D automated blood culture system has the potential to screen platelet concentrates for the presence of bacteria. Evaluation of this system was performed by spiking day 2 apheresis platelet units with individual bacterial isolates at final concentrations of 10 and 100 colony-forming units (cfu) mL-1. Fifteen organisms were used which had been cited in platelet transmission and monitoring studies. BacT/ALERT times to detection were compared with thioglycollate broth cultures, and the performance of five types of BacT/ALERT culture bottles was evaluated. Sampling was performed immediately after the inoculation of the units, and 10 replicates were performed per organism concentration for each of the five types of BacT/ALERT bottles. The mean times for the detection of these 15 organisms by BacT/ALERT, with the exception of Propionibacterium acnes, ranged from 9.1 to 48.1 h (all 10 replicates were positive). In comparison, the time range found using thioglycollate was 12.0-32.3 h (all 10 replicates were positive). P. acnes' BacT/ALERT mean detection times ranged from 89.0 to 177.6 h compared with 75.6-86.4 h for the thioglycollate broth. BacT/ALERT, with the exception of P. acnes, which has dubious clinical significance, gave equivalent or shorter detection times when compared with the thioglycollate broth system. The BacT/ALERT system detected a range of organisms at levels of 10 and 100 cfu mL-1. This study validates the BacT/ALERT microbial detection system for screening platelets. Currently, the system is the only practically viable option available for routinely screening platelet concentrates to prevent bacterial transmission.
NASA aviation safety reporting system
NASA Technical Reports Server (NTRS)
1978-01-01
An analytical study of reports relating to cockpit altitude alert systems was performed. A recent change in the Federal Air Regulation permits the system to be modified so that the alerting signal approaching altitude has only a visual component; the auditory signal would continue to be heard if a deviation from an assigned altitude occurred. Failure to observe altitude alert signals and failure to reset the system were the commonest cause of altitude deviations related to this system. Cockpit crew distraction was the most frequent reason for these failures. It was noted by numerous reporters that the presence of altitude alert system made them less aware of altitude; this lack of altitude awareness is discussed. Failures of crew coordination were also noted. It is suggested that although modification of the altitude alert system may be highly desirable in short-haul aircraft, it may not be desirable for long-haul aircraft in which cockpit workloads are much lower for long periods of time. In these cockpits, the aural alert approaching altitudes is perceived as useful and helpful. If the systems are to be modified, it appears that additional emphasis on altitude awareness during recurrent training will be necessary; it is also possible that flight crew operating procedures during climb and descent may need examination with respect to monitoring responsibilities. A selection of alert bulletins and responses to them is presented.
Kane-Gill, Sandra L; O'Connor, Michael F; Rothschild, Jeffrey M; Selby, Nicholas M; McLean, Barbara; Bonafide, Christopher P; Cvach, Maria M; Hu, Xiao; Konkani, Avinash; Pelter, Michele M; Winters, Bradford D
2017-09-01
To provide ICU clinicians with evidence-based guidance on tested interventions that reduce or prevent alert fatigue within clinical decision support systems. Systematic review of PubMed, Embase, SCOPUS, and CINAHL for relevant literature from 1966 to February 2017. Focus on critically ill patients and included evaluations in other patient care settings, as well. Identified interventions designed to reduce or prevent alert fatigue within clinical decision support systems. Study selection was based on one primary key question to identify effective interventions that attempted to reduce alert fatigue and three secondary key questions that covered the negative effects of alert fatigue, potential unintended consequences of efforts to reduce alert fatigue, and ideal alert quantity. Data were abstracted by two reviewers independently using a standardized abstraction tool. Surveys, meeting abstracts, "gray" literature, studies not available in English, and studies with non-original data were excluded. For the primary key question, articles were excluded if they did not provide a comparator as key question 1 was designed as a problem, intervention, comparison, and outcome question. We anticipated that reduction in alert fatigue, including the concept of desensitization may not be directly measured and thus considered interventions that reduced alert quantity as a surrogate marker for alert fatigue. Twenty-six articles met the inclusion criteria. Approaches for managing alert fatigue in the ICU are provided as a result of reviewing tested interventions that reduced alert quantity with the anticipated effect of reducing fatigue. Suggested alert management strategies include prioritizing alerts, developing sophisticated alerts, customizing commercially available alerts, and including end user opinion in alert selection. Alert fatigue itself is studied less frequently, as an outcome, and there is a need for more precise evaluation. Standardized metrics for alert fatigue is needed to advance the field. Suggestions for standardized metrics are provided in this document.
OGLE ATLAS OF CLASSICAL NOVAE. II. MAGELLANIC CLOUDS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mróz, P.; Udalski, A.; Poleski, R.
2016-01-15
The population of classical novae in the Magellanic Clouds was poorly known because of a lack of systematic studies. There were some suggestions that nova rates per unit mass in the Magellanic Clouds were higher than in any other galaxy. Here, we present an analysis of data collected over 16 years by the OGLE survey with the aim of characterizing the nova population in the Clouds. We found 20 eruptions of novae, half of which are new discoveries. We robustly measure nova rates of 2.4 ± 0.8 yr{sup −1} (LMC) and 0.9 ± 0.4 yr{sup −1} (SMC) and confirm that the K-band luminosity-specific novamore » rates in both Clouds are 2–3 times higher than in other galaxies. This can be explained by the star formation history in the Magellanic Clouds, specifically the re-ignition of the star formation rate a few Gyr ago. We also present the discovery of the intriguing system OGLE-MBR133.25.1160, which mimics recurrent nova eruptions.« less
47 CFR 76.1711 - Emergency alert system (EAS) tests and activation.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 47 Telecommunication 4 2012-10-01 2012-10-01 false Emergency alert system (EAS) tests and activation. 76.1711 Section 76.1711 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) BROADCAST RADIO SERVICES MULTICHANNEL VIDEO AND CABLE TELEVISION SERVICE Documents to be Maintained for Inspection § 76.1711 Emergency alert system (EAS)...
47 CFR 76.1711 - Emergency alert system (EAS) tests and activation.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 47 Telecommunication 4 2014-10-01 2014-10-01 false Emergency alert system (EAS) tests and activation. 76.1711 Section 76.1711 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) BROADCAST RADIO SERVICES MULTICHANNEL VIDEO AND CABLE TELEVISION SERVICE Documents to be Maintained for Inspection § 76.1711 Emergency alert system (EAS)...
Sushko, Iurii; Salmina, Elena; Potemkin, Vladimir A; Poda, Gennadiy; Tetko, Igor V
2012-08-27
The article presents a Web-based platform for collecting and storing toxicological structural alerts from literature and for virtual screening of chemical libraries to flag potentially toxic chemicals and compounds that can cause adverse side effects. An alert is uniquely identified by a SMARTS template, a toxicological endpoint, and a publication where the alert was described. Additionally, the system allows storing complementary information such as name, comments, and mechanism of action, as well as other data. Most importantly, the platform can be easily used for fast virtual screening of large chemical datasets, focused libraries, or newly designed compounds against the toxicological alerts, providing a detailed profile of the chemicals grouped by structural alerts and endpoints. Such a facility can be used for decision making regarding whether a compound should be tested experimentally, validated with available QSAR models, or eliminated from consideration altogether. The alert-based screening can also be helpful for an easier interpretation of more complex QSAR models. The system is publicly accessible and tightly integrated with the Online Chemical Modeling Environment (OCHEM, http://ochem.eu). The system is open and expandable: any registered OCHEM user can introduce new alerts, browse, edit alerts introduced by other users, and virtually screen his/her data sets against all or selected alerts. The user sets being passed through the structural alerts can be used at OCHEM for other typical tasks: exporting in a wide variety of formats, development of QSAR models, additional filtering by other criteria, etc. The database already contains almost 600 structural alerts for such endpoints as mutagenicity, carcinogenicity, skin sensitization, compounds that undergo metabolic activation, and compounds that form reactive metabolites and, thus, can cause adverse reactions. The ToxAlerts platform is accessible on the Web at http://ochem.eu/alerts, and it is constantly growing.
2012-01-01
The article presents a Web-based platform for collecting and storing toxicological structural alerts from literature and for virtual screening of chemical libraries to flag potentially toxic chemicals and compounds that can cause adverse side effects. An alert is uniquely identified by a SMARTS template, a toxicological endpoint, and a publication where the alert was described. Additionally, the system allows storing complementary information such as name, comments, and mechanism of action, as well as other data. Most importantly, the platform can be easily used for fast virtual screening of large chemical datasets, focused libraries, or newly designed compounds against the toxicological alerts, providing a detailed profile of the chemicals grouped by structural alerts and endpoints. Such a facility can be used for decision making regarding whether a compound should be tested experimentally, validated with available QSAR models, or eliminated from consideration altogether. The alert-based screening can also be helpful for an easier interpretation of more complex QSAR models. The system is publicly accessible and tightly integrated with the Online Chemical Modeling Environment (OCHEM, http://ochem.eu). The system is open and expandable: any registered OCHEM user can introduce new alerts, browse, edit alerts introduced by other users, and virtually screen his/her data sets against all or selected alerts. The user sets being passed through the structural alerts can be used at OCHEM for other typical tasks: exporting in a wide variety of formats, development of QSAR models, additional filtering by other criteria, etc. The database already contains almost 600 structural alerts for such endpoints as mutagenicity, carcinogenicity, skin sensitization, compounds that undergo metabolic activation, and compounds that form reactive metabolites and, thus, can cause adverse reactions. The ToxAlerts platform is accessible on the Web at http://ochem.eu/alerts, and it is constantly growing. PMID:22876798
NASA Astrophysics Data System (ADS)
Haenecour, Pierre; Floss, Christine; José, Jordi; Amari, Sachiko; Lodders, Katharina; Jadhav, Manavi; Wang, Alian; Gyngard, Frank
2016-07-01
Presolar grains constitute the remnants of stars that existed before the formation of the solar system. In addition to providing direct information on the materials from which the solar system formed, these grains provide ground-truth information for models of stellar evolution and nucleosynthesis. Here we report the in situ identification of two unique presolar graphite grains from the primitive meteorite LaPaz Icefield 031117. Based on these two graphite grains, we estimate a bulk presolar graphite abundance of {5}-3+7 ppm in this meteorite. One of the grains (LAP-141) is characterized by an enrichment in 12C and depletions in 33,34S, and contains a small iron sulfide subgrain, representing the first unambiguous identification of presolar iron sulfide. The other grain (LAP-149) is extremely 13C-rich and 15N-poor, with one of the lowest 12C/13C ratios observed among presolar grains. Comparison of its isotopic compositions with new stellar nucleosynthesis and dust condensation models indicates an origin in the ejecta of a low-mass CO nova. Grain LAP-149 is the first putative nova grain that quantitatively best matches nova model predictions, providing the first strong evidence for graphite condensation in nova ejecta. Our discovery confirms that CO nova graphite and presolar iron sulfide contributed to the original building blocks of the solar system.
Atypical dust species in the ejecta of classical novae
NASA Astrophysics Data System (ADS)
Helton, L. A.; Evans, A.; Woodward, C. E.; Gehrz, R. D.
2011-03-01
A classical nova outburst arises from a thermonuclear runaway in the hydrogen-rich material accreted onto the surface of a white dwarf in a binary system. These explosions can produce copious amounts of heavy element enriched material that are ejected violently into the surrounding interstellar medium. In some novae, conditions in the ejecta are suitable for the formation of dust of various compositions, including silicates, amorphous carbon, silicon carbide, and hydrocarbons. Multiple dust grain types are sometimes produced in the same system. CO formation in novae may not reach saturation, thus invalidating the usual paradigm in which the C:O ratio determines the dust species. A few novae, such as V705 Cas and DZ Cru, have exhibited emission features near 6, 8, and 11 μmthat are similar to "Unidentified Infrared" (UIR) features, but with significant differences in position and band structure. Here, we present Spitzer IRS spectra of two recent dusty novae, V2361 Cyg and V2362 Cyg, that harbor similar peculiar emission structures superimposed on features arising from carbonaceous grains. In other astronomical objects, such as star forming regions and young stellar objects, emission peaks at 6.2, 7.7, and 11.3 μmhave been associated with polycyclic aromatic hydrocarbon (PAH) complexes. We suggest that hydrogenated amorphous carbon (HAC) may be the source of these features in novae based upon the spectral behavior of the emission features and the conditions under which the dust formed.
Discovery of an old nova shell surrounding the cataclysmic variable V1315 Aql
NASA Astrophysics Data System (ADS)
Sahman, D. I.; Dhillon, V. S.; Littlefair, S. P.; Hallinan, G.
2018-04-01
Following our tentative discovery of a faint shell around V1315 Aql reported in Sahman et al. (2015), we undertook deep Hα imaging and intermediate-resolution spectroscopy of the shell. We find that the shell has its geometric centre located on V1315 Aql. The mass, spectral features and density of the shell are consistent with other nova shells, rather than planetary nebulae or supernova remnants. The radial velocity of the shell is consistent with the systemic velocity of V1315 Aql. We believe this evidence strongly suggests that the shell originates from an earlier nova event. This is the first nova shell discovered around a novalike, and supports the theory of nova-induced cycles in mass transfer rates (hibernation theory) first proposed by Shara et al. (1986).
Fermi Establishes Classical Novae as a Distinct Class of Gamma-ray Sources
NASA Technical Reports Server (NTRS)
Ackermann, M.; Ajello, M.; Albert, A.; Baldini, L.; Ballet, J.; Bastieri, D.; Bellazzini, R.; Bissaldi, E.; Blandford, R. D.; Bloom, E. D.;
2014-01-01
A classical nova results from runaway thermonuclear explosions on the surface of a white dwarf that accretes matter from a low-mass main-sequence stellar companion. In 2012 and 2013, three novae were detected in gamma rays and stood in contrast to the first gamma-ray detected nova V407 Cygni 2010, which belongs to a rare class of symbiotic binary systems. Despite likely differences in the compositions and masses of their white dwarf progenitors, the three classical novae are similarly characterized as soft spectrum transient gamma-ray sources detected over 2-3 week durations. The gamma-ray detections point to unexpected high-energy particle acceleration processes linked to the mass ejection from thermonuclear explosions in an unanticipated class of Galactic gamma-ray sources.
Fermi establishes classical novae as a distinct class of gamma-ray sources
Cheung, C. C.
2014-07-31
A classical nova results from runaway thermonuclear explosions on the surface of a white dwarf that accretes matter from a low-mass main-sequence stellar companion. In 2012 and 2013, three novae were detected in γ rays and stood in contrast to the first γ-ray detected nova V407 Cygni 2010, which belongs to a rare class of symbiotic binary systems. Despite likely differences in the compositions and masses of their white dwarf progenitors, the three classical novae are similarly characterized as soft spectrum transient γ-ray sources detected over 2-3 week durations. The γ-ray detections point to unexpected high-energy particle acceleration processes linkedmore » to the mass ejection from thermonuclear explosions in an unanticipated class of Galactic γ-ray sources.« less
Maximizing Trust in the Wireless Emergency Alerts (WEA) Service
2014-02-01
Homeland Security under Contract No. FA8721-05-C-0003 with Carnegie Mellon University for the operation of the Software En - gineering Institute, a...AOs will protect their alert-generating systems from misuse. A compro- mised alert-generating system could overload the IPAWS-OPEN message validation...greater accessibility, such as accessing the WEA service re- motely from the scene of an incident. Although we are currently unaware of any alerting
Evaluation of Antimicrobial Stewardship-Related Alerts Using a Clinical Decision Support System.
Ghamrawi, Riane J; Kantorovich, Alexander; Bauer, Seth R; Pallotta, Andrea M; Sekeres, Jennifer K; Gordon, Steven M; Neuner, Elizabeth A
2017-11-01
Background: Information technology, including clinical decision support systems (CDSS), have an increasingly important and growing role in identifying opportunities for antimicrobial stewardship-related interventions. Objective: The aim of this study was to describe and compare types and outcomes of CDSS-built antimicrobial stewardship alerts. Methods: Fifteen alerts were evaluated in the initial antimicrobial stewardship program (ASP) review. Preimplementation, alerts were reviewed retrospectively. Postimplementation, alerts were reviewed in real-time. Data collection included total number of actionable alerts, recommendation acceptance rates, and time spent on each alert. Time to de-escalation to narrower spectrum agents was collected. Results: In total, 749 alerts were evaluated. Overall, 306 (41%) alerts were actionable (173 preimplementation, 133 postimplementation). Rates of actionable alerts were similar for custom-built and prebuilt alert types (39% [53 of 135] vs 41% [253 of 614], P = .68]. In the postimplementation group, an intervention was attempted in 97% of actionable alerts and 70% of interventions were accepted. The median time spent per alert was 7 minutes (interquartile range [IQR], 5-13 minutes; 15 [12-17] minutes for actionable alerts vs 6 [5-7] minutes for nonactionable alerts, P < .001). In cases where the antimicrobial was eventually de-escalated, the median time to de-escalation was 28.8 hours (95% confidence interval [CI], 10.0-69.1 hours) preimplementation vs 4.7 hours (95% CI, 2.4-22.1 hours) postimplementation, P < .001. Conclusions: CDSS have played an important role in ASPs to help identify opportunities to optimize antimicrobial use through prebuilt and custom-built alerts. As ASP roles continue to expand, focusing time on customizing institution specific alerts will be of vital importance to help redistribute time needed to manage other ASP tasks and opportunities.
47 CFR 10.320 - Provider alert gateway requirements.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 47 Telecommunication 1 2014-10-01 2014-10-01 false Provider alert gateway requirements. 10.320 Section 10.320 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL WIRELESS EMERGENCY ALERTS System Architecture § 10.320 Provider alert gateway requirements. This section specifies the functions...
47 CFR 10.320 - Provider alert gateway requirements.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 47 Telecommunication 1 2013-10-01 2013-10-01 false Provider alert gateway requirements. 10.320 Section 10.320 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL WIRELESS EMERGENCY ALERTS System Architecture § 10.320 Provider alert gateway requirements. This section specifies the functions...
47 CFR 10.410 - Prioritization.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 47 Telecommunication 1 2012-10-01 2012-10-01 false Prioritization. 10.410 Section 10.410 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM Alert Message... required to transmit Imminent Threat Alerts and AMBER Alerts on a first in-first out (FIFO) basis. ...
Generalized Philosophy of Alerting with Applications for Parallel Approach Collision Prevention
NASA Technical Reports Server (NTRS)
Winder, Lee F.; Kuchar, James K.
2000-01-01
The goal of the research was to develop formal guidelines for the design of hazard avoidance systems. An alerting system is automation designed to reduce the likelihood of undesirable outcomes that are due to rare failures in a human-controlled system. It accomplishes this by monitoring the system, and issuing warning messages to the human operators when thought necessary to head off a problem. On examination of existing and recently proposed logics for alerting it appears that few commonly accepted principles guide the design process. Different logics intended to address the same hazards may take disparate forms and emphasize different aspects of performance, because each reflects the intuitive priorities of a different designer. Because performance must be satisfactory to all users of an alerting system (implying a universal meaning of acceptable performance) and not just one designer, a proposed logic often undergoes significant piecemeal modification before gamma general acceptance. This report is an initial attempt to clarify the common performance goals by which an alerting system is ultimately judged. A better understanding of these goals will hopefully allow designers to reach the final logic in a quicker, more direct and repeatable manner. As a case study, this report compares three alerting logics for collision prevention during independent approaches to parallel runways, and outlines a fourth alternative incorporating elements of the first three, but satisfying stated requirements. Three existing logics for parallel approach alerting are described. Each follows from different intuitive principles. The logics are presented as examples of three "philosophies" of alerting system design.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-04-20
... Committee 147: Minimum Operational Performance Standards for Traffic Alert and Collision Avoidance Systems... Committee 147: Minimum Operational Performance Standards for Traffic Alert and Collision Avoidance Systems... RTCA Special Committee 147: Minimum Operational Performance Standards for Traffic Alert and Collision...
Comparative Analysis of ACAS-Xu and DAIDALUS Detect-and-Avoid Systems
NASA Technical Reports Server (NTRS)
Davies, Jason T.; Wu, Minghong G.
2018-01-01
The Detect and Avoid (DAA) capability of a recent version (Run 3) of the Airborne Collision Avoidance System-Xu (ACAS-Xu) is measured against that of the Detect and AvoID Alerting Logic for Unmanned Systems (DAIDALUS), a reference algorithm for the Phase 1 Minimum Operational Performance Standards (MOPS) for DAA. This comparative analysis of the two systems' alerting and horizontal guidance outcomes is conducted through the lens of the Detect and Avoid mission using flight data of scripted encounters from a recent flight test. Results indicate comparable timelines and outcomes between ACAS-Xu's Remain Well Clear alert and guidance and DAIDALUS's corrective alert and guidance, although ACAS-Xu's guidance appears to be more conservative. ACAS-Xu's Collision Avoidance alert and guidance occurs later than DAIDALUS's warning alert and guidance, and overlaps with DAIDALUS's timeline of maneuver to remain Well Clear. Interesting discrepancies between ACAS-Xu's directive guidance and DAIDALUS's "Regain Well Clear" guidance occur in some scenarios.
21 CFR 26.50 - Alert system and exchange of postmarket vigilance reports.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 1 2011-04-01 2011-04-01 false Alert system and exchange of postmarket vigilance reports. 26.50 Section 26.50 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... postmarket vigilance reports. (a) An alert system will be set up during the transition period and maintained...
75 FR 49368 - Airworthiness Directives; Rolls-Royce plc (RR) RB211-Trent 900 Series Turbofan Engines
Federal Register 2010, 2011, 2012, 2013, 2014
2010-08-13
...-Royce Trent 900 Series Propulsion Systems Alert Non- Modification Service Bulletin (NMSB) RB.211-72... Propulsion Systems Alert NMSB RB.211-72-AG329, Revision 1, dated January 13, 2010. The actions described in... Series Propulsion Systems Alert Non-Modification Service Bulletin (NMSB) RB.211-72-AG329, Revision 1...
NASA Technical Reports Server (NTRS)
La Dous, Constanze
1991-01-01
IUE observations of dwarf novae at maximum at quiescence and novalike objects at the high brightness state are analyzed for effects of the inclination angle on the emitted continuum and line radiation. A clear pattern in the continuum flux distribution is exhibited only by dwarf novae at maximum where some 80 percent of the non-double-eclipsing systems show essentially identical distributions. This result is not in disagreement with theoretical expectations. All classes of objects exhibit a clear, but in each case different, dependence of the line radiation on the inclination angle.
NASA Astrophysics Data System (ADS)
Crosby, Norma; Veronig, Astrid; Rodriguez, Luciano; Vrsnak, Bojan; Vennerstrom, Susanne; Malandraki, Olga; Dalla, Silvia; Srivastava, Nandita; Hesse, Michael; Odstrcil, Dusan; Robbrecht, Eva
2014-05-01
Tools for forecasting geomagnetic storms and solar energetic particle (SEP) radiation storms have been developed under the three-year EU FP7 COMESEP (COronal Mass Ejections and Solar Energetic Particles) collaborative project. To enhance our understanding of the 3D kinematics and interplanetary propagation of coronal mass ejections (CMEs), the structure, propagation and evolution of CMEs have been investigated. In parallel, the sources and propagation of SEPs have been examined and modeled. During the third year of the COMESEP project the produced tools have been validated and implemented into an operational space weather alert system. The COMESEP Alert System provides notifications for the space weather community. To achieve this the system relies on both models and data, the latter including near real-time data as well as historical data. Geomagnetic and SEP radiation storm alerts are based on the COMESEP definition of risk. The COMESEP Alert System has recently been launched. Receiving COMESEP alerts are free of charge, but registration is required. For more information see the project website (http://www.comesep.eu/). This work has received funding from the European Commission FP7 Project COMESEP (263252).
Benthin, Cody; Pannu, Sonal; Khan, Akram; Gong, Michelle
2016-10-01
The nature, variability, and extent of early warning clinical practice alerts derived from automated query of electronic health records (e-alerts) currently used in acute care settings for clinical care or research is unknown. To describe e-alerts in current use in acute care settings at medical centers participating in a nationwide critical care research network. We surveyed investigators at 38 institutions involved in the National Institutes of Health-funded Clinical Trials Network for the Prevention and Early Treatment of Acute Lung Injury (PETAL) for quantitative and qualitative analysis. Thirty sites completed the survey (79% response rate). All sites used electronic health record systems. Epic Systems was used at 56% of sites; the others used alternate commercially available vendors or homegrown systems. Respondents at 57% of sites represented in this survey used e-alerts. All but 1 of these 17 sites used an e-alert for early detection of sepsis-related syndromes, and 35% used an e-alert for pneumonia. E-alerts were triggered by abnormal laboratory values (37%), vital signs (37%), or radiology reports (15%) and were used about equally for clinical decision support and research. Only 59% of sites with e-alerts have evaluated them either for accuracy or for validity. A majority of the research network sites participating in this survey use e-alerts for early notification of potential threats to hospitalized patients; however, there was significant variability in the nature of e-alerts between institutions. Use of one common electronic health record vendor at more than half of the participating sites suggests that it may be possible to standardize e-alerts across multiple sites in research networks, particularly among sites using the same medical record platform.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-08-26
... Committee 147: Minimum Operational Performance Standards for Traffic Alert and Collision Avoidance Systems... Committee 147: Minimum Operational Performance Standards for Traffic Alert and Collision Avoidance Systems... RTCA Special Committee 147: Minimum Operational Performance Standards for Traffic Alert and Collision...
Impact of e-alert systems on the care of patients with acute kidney injury.
Breighner, Crystal M; Kashani, Kianoush B
2017-09-01
With the recent advancement in electronic health record systems and meaningful use of information technology incentive programs (i.e., the American Recovery and Reinvestment Act, the Health Information Technology for Economic and Clinical Health Act, and the Centers for Medicare & Medicaid Services), interest in clinical decision support systems has risen. These systems have been used to examine a variety of different syndromes with variable reported effects. In recent years, electronic alerts (e-alerts) have been implemented at various institutions to decrease the morbidity associated with acute kidney injury (AKI). AKI is common, accounting for 1 in 7 hospital admissions, and is associated with increased length of hospital stay and mortality. AKI is often underrecognized, causing delayed intervention. The use of e-alerts may result in earlier recognition and intervention, as well as decreased morbidity and mortality. This must be balanced with the possibility of increased resource utilization that e-alerts may cause. Before widespread implementation, the ethical and legal consequences of not following e-alert recommendations must be established, and the optimal algorithm for AKI e-alert detection must be determined. Copyright © 2017 Elsevier Ltd. All rights reserved.
Wasser, Tobias D; Fox, Patrick K
2013-01-01
The Silver Alert system was initially created to help protect missing persons who have cognitive impairments, particularly the elderly. The Silver Alert is modeled after the Amber Alert, created to help locate and safeguard missing children. Unlike the Amber Alert, however, in most states the Silver Alert applies to the elderly, adults with a mental impairment, or both, depending on the state. The goal of the Silver Alert system is the quick dissemination of information about missing persons to law enforcement personnel as well as to the general public. Previously, states notified law enforcement personnel of missing persons through teletype to other public safety jurisdictions to enlist their assistance in the retrieval of the missing person. Silver Alert programs substantially expand the notification to include the general public, who receive information through radio and television broadcasts as well as highway billboards. The programs serve a legitimate governmental interest by protecting a vulnerable population from possible harm. Yet, the implementation of these alerts can have unintended consequences, including the possible violation of an individual's right to privacy. Such consequences require careful consideration.
An MFC-Based Online Monitoring and Alert System for Activated Sludge Process
Xu, Gui-Hua; Wang, Yun-Kun; Sheng, Guo-Ping; Mu, Yang; Yu, Han-Qing
2014-01-01
In this study, based on a simple, compact and submersible microbial fuel cell (MFC), a novel online monitoring and alert system with self-diagnosis function was established for the activated sludge (AS) process. Such a submersible MFC utilized organic substrates and oxygen in the AS reactor as the electron donor and acceptor respectively, and could provide an evaluation on the status of the AS reactor and thus give a reliable early warning of potential risks. In order to evaluate the reliability and sensitivity of this online monitoring and alert system, a series of tests were conducted to examine the response of this system to various shocks imposed on the AS reactor. The results indicate that this online monitoring and alert system was highly sensitive to the performance variations of the AS reactor. The stability, sensitivity and repeatability of this online system provide feasibility of being incorporated into current control systems of wastewater treatment plants to real-time monitor, diagnose, alert and control the AS process. PMID:25345502
Practitioners’ Views on Computerized Drug–Drug Interaction Alerts in the VA System
Ko, Yu; Abarca, Jacob; Malone, Daniel C.; Dare, Donna C.; Geraets, Doug; Houranieh, Antoun; Jones, William N.; Nichol, W. Paul; Schepers, Gregory P.; Wilhardt, Michelle
2007-01-01
Objectives To assess Veterans Affairs (VA) prescribers’ and pharmacists’ opinions about computer-generated drug–drug interaction (DDI) alerts and obtain suggestions for improving DDI alerts. Design A mail survey of 725 prescribers and 142 pharmacists from seven VA medical centers across the United States. Measurements A questionnaire asked respondents about their sources of drug and DDI information, satisfaction with the combined inpatient and outpatient computerized prescriber order entry (CPOE) system, attitude toward DDI alerts, and suggestions for improving DDI alerts. Results The overall response rate was 40% (prescribers: 36%; pharmacists: 59%). Both prescribers and pharmacists indicated that the CPOE system had a neutral to positive impact on their jobs. DDI alerts were not viewed as a waste of time and the majority (61%) of prescribers felt that DDI alerts had increased their potential to prescribe safely. However, only 30% of prescribers felt DDI alerts provided them with what they needed most of the time. Both prescribers and pharmacists agreed that DDI alerts should be accompanied by management alternatives (73% and 82%, respectively) and more detailed information (65% and 89%, respectively). When asked about suggestions for improving DDI alerts, prescribers most preferred including management options whereas pharmacists most preferred making it more difficult to override lethal interactions. Prescribers and pharmacists reported primarily relying on electronic references for general drug information (62% and 55%, respectively) and DDI information (51% and 79%, respectively). Conclusion Respondents reported neutral to positive views regarding the effect of CPOE on their jobs. Their opinions suggest DDI alerts are useful but still require additional work to increase their clinical utility. PMID:17068346
Context-Sensitive Clinical Alert Packages Written in Arden Syntax.
Zeckl, Julia; Adlassnig, Katharina; Fossler, Renate; Blacky, Alexander; de Bruin, Jeroen S; Koller, Walter; Rappelsberger, Andrea; Adlassnig, Klaus-Peter
2017-01-01
An increasing body of raw patient data is generated on each day of a patient's stay at a hospital. It is of paramount importance that critical patient information be extracted from these large data volumes and presented to the patient's clinical caregivers as early as possible. Contemporary clinical alert systems attempt to provide this service with moderate success. The efficacy of the systems is limited by the fact that they are too general to fit specific patient populations or healthcare institutions. In this study we present an extendable alerting framework implemented in Arden Syntax, which can be configured to the needs and preferences of healthcare institutions and individual patient caregivers. We illustrate the potential of this alerting framework via an alert package that analyzes hematological laboratory results with data from intensive care units at the Vienna General Hospital, Austria. The results show the effectiveness of this alert package and its ability to generate key alerts while avoiding over-alerting.
Lippi, Giuseppe; Brambilla, Marco; Bonelli, Patrizia; Aloe, Rosalia; Balestrino, Antonio; Nardelli, Anna; Ceda, Gian Paolo; Fabi, Massimo
2015-11-01
There is consolidated evidence that the burden of inappropriate laboratory test requests is very high, up to 70%. We describe here the function of a computerized alert system linked to the order entry, designed to limit the number of potentially inappropriate laboratory test requests. A computerized alert system based on re-testing intervals and entailing the generation of pop-up alerts when preset criteria of appropriateness for 15 laboratory tests were violated was implemented in two clinical wards of the University Hospital of Parma. The effectiveness of the system for limiting potentially inappropriate tests was monitored for 6months. Overall, 765/3539 (22%) test requests violated the preset criteria of appropriateness and generated the appearance of electronic alert. After alert appearance, 591 requests were annulled (17% of total tests requested and 77% of tests alerted, respectively). The total number of test requests violating the preset criteria of inappropriateness constantly decreased over time (26% in the first three months of implementation versus 17% in the following period; p<0.001). The total financial saving of test withdrawn was 3387 Euros (12.8% of the total test cost) throughout the study period. The results of this study suggest that a computerized alert system may be effective to limit the inappropriateness of laboratory test requests, generating significant economic saving and educating physicians to a more efficient use of laboratory resources. Copyright © 2015 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
X ray and gamma ray emission from classical nova outbursts
NASA Technical Reports Server (NTRS)
Truran, James W.; Starrfield, Sumner; Sparks, Warren M.
1992-01-01
The outbursts of classical novae are now recognized to be consequences of thermonuclear runaways proceeding in accreted hydrogen-rich shells on white dwarfs in close binary systems. For the conditions that are known to exist in these environments, it is expected that soft x-rays can be emitted, and indeed x-rays were detected from a number of novae. The circumstances for which we expect novae to produce significant x-ray fluxes and provide estimates of the luminosities and effective temperatures are described. It is also known that at the high temperatures that are known to be achieved in this explosive hydrogen-burning environment, significant production of both Na-22 and Al-26 will occur. In this context, we identify the conditions for which gamma-ray emission may be expected to result from nova outbursts.
Performance Evaluation of Evasion Maneuvers for Parallel Approach Collision Avoidance
NASA Technical Reports Server (NTRS)
Winder, Lee F.; Kuchar, James K.; Waller, Marvin (Technical Monitor)
2000-01-01
Current plans for independent instrument approaches to closely spaced parallel runways call for an automated pilot alerting system to ensure separation of aircraft in the case of a "blunder," or unexpected deviation from the a normal approach path. Resolution advisories by this system would require the pilot of an endangered aircraft to perform a trained evasion maneuver. The potential performance of two evasion maneuvers, referred to as the "turn-climb" and "climb-only," was estimated using an experimental NASA alerting logic (AILS) and a computer simulation of relative trajectory scenarios between two aircraft. One aircraft was equipped with the NASA alerting system, and maneuvered accordingly. Observation of the rates of different types of alerting failure allowed judgement of evasion maneuver performance. System Operating Characteristic (SOC) curves were used to assess the benefit of alerting with each maneuver.
Participatory design for drug-drug interaction alerts.
Luna, Daniel; Otero, Carlos; Almerares, Alfredo; Stanziola, Enrique; Risk, Marcelo; González Bernaldo de Quirós, Fernán
2015-01-01
The utilization of decision support systems, in the point of care, to alert drug-drug interactions has been shown to improve quality of care. Still, the use of these systems has not been as expected, it is believed, because of the difficulties in their knowledge databases; errors in the generation of the alerts and the lack of a suitable design. This study expands on the development of alerts using participatory design techniques based on user centered design process. This work was undertaken in three stages (inquiry, participatory design and usability testing) it showed that the use of these techniques improves satisfaction, effectiveness and efficiency in an alert system for drug-drug interactions, a fact that was evident in specific situations such as the decrease of errors to meet the specified task, the time, the workload optimization and users overall satisfaction in the system.
76 FR 14797 - Airworthiness Directives; Rolls-Royce plc (RR) RB211-Trent 900 Series Turbofan Engines
Federal Register 2010, 2011, 2012, 2013, 2014
2011-03-18
.... Relevant Service Information Rolls-Royce plc has issued Trent 900 Series Propulsion Systems Alert Service... incorporating software 10.6 can be found in Rolls-Royce plc Trent 900 Series Propulsion Systems Alert Service... Propulsion Systems Alert SB No. RB.211-73-AG639, dated December 3, 2010, for related information. (i) Contact...
Baiguini, Alessandro; Colletta, Stefano; Rebella, Valentina
2011-01-01
For some time, packaging materials and articles intended to come into contact with food are included in the system of controls, early warnings and risk communication provided by the European Commission (EU) regulation 178/2002. Data analysis of the EU rapid alert system for food allows one to define a specific risk profile and to establish an effective plan for official control of materials intended to come into contact with food. In the 2008-2010 period the rapid alert system has ratified alert notifications, mostly related to plastic materials of Chinese origin.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-06-06
...; Integrated Public Alert and Warning Systems (IPAWS) Inventory AGENCY: Federal Emergency Management Agency... proposed revision of the information collection concerning public alert and warning systems at the Federal... evaluation and assessment of existing public alert and warning resources and their integration with the...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-11-23
... Appraiser Roster regulations by replacing the obsolete references to the Credit Alert Interactive Voice Response System (CAIVRS) with references to its successor, the online-based Credit Alert Verification... propose the elimination references to the Credit Alert Interactive Voice Response System (CAIVRS). On July...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-08-31
... Request, Integrated Public Alert and Warning Systems (IPAWS) Inventory AGENCY: Federal Emergency... system to alert and warn the American people in situations of war, terrorist attack, natural disaster, or... inventory of public alert and warning resources, capabilities, and the degree of integration at the Federal...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-07-14
... the FHA Appraiser Roster by replacing the obsolete references to the Credit Alert Interactive Voice Response System with references to its successor, the online-based Credit Alert Verification Reporting...'s Limited Denial of Participation list, or in HUD's Credit Alert Interactive Voice Response System...
On the Progenitor System of V392 Persei
NASA Astrophysics Data System (ADS)
Darnley, M. J.; Starrfield, S.
2018-05-01
A discussion regarding the progenitor system of the nova and dwarf nova system V392 Persei using archival data from 2MASS and WISE. We find that the system is unlikely to contain a luminous red giant donor (i.e. a symbiotic system), but cannot exclude the presence of a lower luminosity red giant or a sub-giant donor. The similarity of the SED of the quiescent V392 Per to that of GK Persei is noted.
Electronic Immunization Alerts and Spillover Effects on Other Preventive Care.
Kim, Julia M; Rivera, Maria; Persing, Nichole; Bundy, David G; Psoter, Kevin J; Ghazarian, Sharon R; Miller, Marlene R; Solomon, Barry S
2017-08-01
The impact of electronic health record (EHR) immunization clinical alert systems on the delivery of other preventive services remains unknown. We assessed for spillover effects of an EHR immunization alert on delivery of 6 other preventive services, in children 18 to 30 months of age needing immunizations. We conducted a secondary data analysis, with additional primary data collection, of a randomized, historically controlled trial to improve immunization rates with EHR alerts, in an urban, primary care clinic. No significant differences were found in screening for anemia, lead, development, nutrition, and injury prevention counseling in children prompting EHR immunization alerts (n = 129), compared with controls (n = 135). Significant increases in oral health screening in patients prompting EHR alerts (odds ratio = 4.8, 95% CI = 1.8-13.0) were likely due to practice changes over time. An EHR clinical alert system targeting immunizations did not have a spillover effect on the delivery of other preventive services.
Synthesis of C-rich dust in CO nova outbursts
NASA Astrophysics Data System (ADS)
José, Jordi; Halabi, Ghina M.; El Eid, Mounib F.
2016-09-01
Context. Classical novae are thermonuclear explosions that take place in the envelopes of accreting white dwarfs in stellar binary systems. The material transferred onto the white dwarf piles up under degenerate conditions, driving a thermonuclear runaway. In these outbursts, about 10-7-10-3 M⊙, enriched in CNO and sometimes other intermediate-mass elements (e.g., Ne, Na, Mg, or Al for ONe novae) are ejected into the interstellar medium. The large concentrations of metals spectroscopically inferred in the nova ejecta reveal that the solar-like material transferred from the secondary mixes with the outermost layers of the underlying white dwarf. Aims: Most theoretical models of nova outbursts reported to date yield, on average, outflows characterized by O > C, from which, in principle, only oxidized condensates (e.g., O-rich grains) would be expected. Methods: To specifically address whether CO novae can actually produce C-rich dust, six different hydrodynamic nova models have been evolved, from accretion to the expansion and ejection stages, with different choices for the composition of the substrate with which the solar-like accreted material mixes. Updated chemical profiles inside the H-exhausted core have been used, based on stellar evolution calculations for a progenitor of 8 M⊙ through H- and He-burning phases. Results: We show that these profiles lead to C-rich ejecta after the nova outburst. This extends the possible contribution of novae to the inventory of presolar grains identified in meteorites, particularly in a number of carbonaceous phases (I.e., nanodiamonds, silicon carbides, and graphites).
Modeling Pilot State in Next Generation Aircraft Alert Systems
NASA Technical Reports Server (NTRS)
Carlin, Alan S.; Alexander, Amy L.; Schurr, Nathan
2011-01-01
The Next Generation Air Transportation System will introduce new, advanced sensor technologies into the cockpit that must convey a large number of potentially complex alerts. Our work focuses on the challenges associated with prioritizing aircraft sensor alerts in a quick and efficient manner, essentially determining when and how to alert the pilot This "alert decision" becomes very difficult in NextGen due to the following challenges: 1) the increasing number of potential hazards, 2) the uncertainty associated with the state of potential hazards as well as pilot slate , and 3) the limited time to make safely-critical decisions. In this paper, we focus on pilot state and present a model for anticipating duration and quality of pilot behavior, for use in a larger system which issues aircraft alerts. We estimate pilot workload, which we model as being dependent on factors including mental effort, task demands. and task performance. We perform a mathematically rigorous analysis of the model and resulting alerting plans. We simulate the model in software and present simulated results with respect to manipulation of the pilot measures.
McDaniel, Robert B; Burlison, Jonathan D; Baker, Donald K; Hasan, Murad; Robertson, Jennifer; Hartford, Christine; Howard, Scott C; Sablauer, Andras; Hoffman, James M
2016-04-01
Metrics for evaluating interruptive prescribing alerts have many limitations. Additional methods are needed to identify opportunities to improve alerting systems and prevent alert fatigue. In this study, the authors determined whether alert dwell time-the time elapsed from when an interruptive alert is generated to when it is dismissed-could be calculated by using historical alert data from log files. Drug-drug interaction (DDI) alerts from 3 years of electronic health record data were queried. Alert dwell time was calculated for 25,965 alerts, including 777 unique DDIs. The median alert dwell time was 8 s (range, 1-4913 s). Resident physicians had longer median alert dwell times than other prescribers (P < 001). The 10 most frequent DDI alerts (n = 8759 alerts) had shorter median dwell times than alerts that only occurred once (P < 001). This metric can be used in future research to evaluate the effectiveness and efficiency of interruptive prescribing alerts. © The Author 2015. Published by Oxford University Press on behalf of the American Medical Informatics Association. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
ERIC Educational Resources Information Center
WGBH-TV, Boston, MA.
News clippings, reviews, and feature articles about the Public Broadcasting System science-adventure series "Nova" are collected here. Included are comments from the New York Times, Washington Post, Christian Science Monitor, and TV Guide. Commentaries are primarily favorable and include synopses of various episodes. (DGC)
James, Matthew T; Hobson, Charles E; Darmon, Michael; Mohan, Sumit; Hudson, Darren; Goldstein, Stuart L; Ronco, Claudio; Kellum, John A; Bagshaw, Sean M
2016-01-01
Electronic medical records and clinical information systems are increasingly used in hospitals and can be leveraged to improve recognition and care for acute kidney injury. This Acute Dialysis Quality Initiative (ADQI) workgroup was convened to develop consensus around principles for the design of automated AKI detection systems to produce real-time AKI alerts using electronic systems. AKI alerts were recognized by the workgroup as an opportunity to prompt earlier clinical evaluation, further testing and ultimately intervention, rather than as a diagnostic label. Workgroup members agreed with designing AKI alert systems to align with the existing KDIGO classification system, but recommended future work to further refine the appropriateness of AKI alerts and to link these alerts to actionable recommendations for AKI care. The consensus statements developed in this review can be used as a roadmap for development of future electronic applications for automated detection and reporting of AKI.
Simpao, Allan F; Ahumada, Luis M; Desai, Bimal R; Bonafide, Christopher P; Gálvez, Jorge A; Rehman, Mohamed A; Jawad, Abbas F; Palma, Krisha L; Shelov, Eric D
2015-03-01
To develop and evaluate an electronic dashboard of hospital-wide electronic health record medication alerts for an alert fatigue reduction quality improvement project. We used visual analytics software to develop the dashboard. We collaborated with the hospital-wide Clinical Decision Support committee to perform three interventions successively deactivating clinically irrelevant drug-drug interaction (DDI) alert rules. We analyzed the impact of the interventions on care providers' and pharmacists' alert and override rates using an interrupted time series framework with piecewise regression. We evaluated 2 391 880 medication alerts between January 31, 2011 and January 26, 2014. For pharmacists, the median alert rate prior to the first DDI deactivation was 58.74 alerts/100 orders (IQR 54.98-60.48) and 25.11 alerts/100 orders (IQR 23.45-26.57) following the three interventions (p<0.001). For providers, baseline median alert rate prior to the first round of DDI deactivation was 19.73 alerts/100 orders (IQR 18.66-20.24) and 15.11 alerts/100 orders (IQR 14.44-15.49) following the three interventions (p<0.001). In a subgroup analysis, we observed a decrease in pharmacists' override rates for DDI alerts that were not modified in the system from a median of 93.06 overrides/100 alerts (IQR 91.96-94.33) to 85.68 overrides/100 alerts (IQR 84.29-87.15, p<0.001). The medication serious safety event rate decreased during the study period, and there were no serious safety events reported in association with the deactivated alert rules. An alert dashboard facilitated safe rapid-cycle reductions in alert burden that were temporally associated with lower pharmacist override rates in a subgroup of DDIs not directly affected by the interventions; meanwhile, the pharmacists' frequency of selecting the 'cancel' option increased. We hypothesize that reducing the alert burden enabled pharmacists to devote more attention to clinically relevant alerts. © The Author 2014. Published by Oxford University Press on behalf of the American Medical Informatics Association. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
47 CFR 11.56 - EAS Participants receive CAP-formatted alerts.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 47 Telecommunication 1 2010-10-01 2010-10-01 false EAS Participants receive CAP-formatted alerts... SYSTEM (EAS) Emergency Operations § 11.56 EAS Participants receive CAP-formatted alerts. Notwithstanding anything herein to the contrary, all EAS Participants must be able to receive CAP-formatted EAS alerts no...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-05-11
...] Draft Programmatic Environmental Assessment for the Integrated Public Alert and Warning Program's... from construction- related actions taken under the Integrated Public Alert and Warning Program (IPAWS... Order 13407, Public Alert and Warning System, by providing robust and survivable power generation, fuel...
NASA Astrophysics Data System (ADS)
Masato, Giacomo; Cavany, Sean; Charlton-Perez, Andrew; Dacre, Helen; Bone, Angie; Carmicheal, Katie; Murray, Virginia; Danker, Rutger; Neal, Rob; Sarran, Christophe
2015-04-01
The health forecasting alert system for cold weather and heatwaves currently in use in the Cold Weather and Heatwave plans for England is based on 5 alert levels, with levels 2 and 3 dependent on a forecast or actual single temperature action trigger. Epidemiological evidence indicates that for both heat and cold, the impact on human health is gradual, with worsening impact for more extreme temperatures. The 60% risk of heat and cold forecasts used by the alerts is a rather crude probabilistic measure, which could be substantially improved thanks to the state-of-the-art forecast techniques. In this study a prototype of a new health forecasting alert system is developed, which is aligned to the approach used in the Met Office's (MO) National Severe Weather Warning Service (NSWWS). This is in order to improve information available to responders in the health and social care system by linking temperatures more directly to risks of mortality, and developing a system more coherent with other weather alerts. The prototype is compared to the current system in the Cold Weather and Heatwave plans via a case-study approach to verify its potential advantages and shortcomings. The prototype health forecasting alert system introduces an "impact vs likelihood matrix" for the health impacts of hot and cold temperatures which is similar to those used operationally for other weather hazards as part of the NSWWS. The impact axis of this matrix is based on existing epidemiological evidence, which shows an increasing relative risk of death at extremes of outdoor temperature beyond a threshold which can be identified epidemiologically. The likelihood axis is based on a probability measure associated with the temperature forecast. The new method is tested for two case studies (one during summer 2013, one during winter 2013), and compared to the performance of the current alert system. The prototype shows some clear improvements over the current alert system. It allows for a much greater degree of flexibility, provides more detailed regional information about the health risks associated with periods of extreme temperatures, and is more coherent with other weather alerts which may make it easier for front line responders to use. It will require validation and engagement with stakeholders before it can be considered for use.
Managing the Alert Process at NewYork-Presbyterian Hospital
Kuperman, Gilad J; Diamente, Rosanna; Khatu, Vrinda; Chan-Kraushar, Terri; Stetson, Pete; Boyer, Aurelia; Cooper, Mary
2005-01-01
Clinical decision support can improve the quality of care, but requires substantial knowledge management activities. At NewYork-Presbyterian Hospital in New York City, we have implemented a formal alert management process whereby only hospital committees and departments can request alerts. An explicit requestor, who will help resolve the details of the alert logic and the alert message must be identified. Alerts must be requested in writing using a structured alert request form. Alert requests are reviewed by the Alert Committee and then forwarded to the Information Systems department for a software development estimate. The model required that clinical committees and departments become more actively involved in the development of alerts than had previously been necessary. In the 12 months following implementation, 10 alert requests were received. The model has been well received. A lot of the knowledge engineering work has been distributed and burden has been removed from scarce medical informatics resources. PMID:16779073
Archer, Melissa; Proulx, Joshua; Shane-McWhorter, Laura; Bray, Bruce E; Zeng-Treitler, Qing
2014-01-01
While potential medication-to-medication interaction alerting engines exist in many clinical applications, few systems exist to automatically alert on potential medication to herbal supplement interactions. We have developed a preliminary knowledge base and rules alerting engine that detects 259 potential interactions between 9 supplements, 62 cardiac medications, and 19 drug classes. The rules engine takes into consideration 12 patient risk factors and 30 interaction warning signs to help determine which of three different alert levels to categorize each potential interaction. A formative evaluation was conducted with two clinicians to set initial thresholds for each alert level. Additional work is planned add more supplement interactions, risk factors, and warning signs as well as to continue to set and adjust the inputs and thresholds for each potential interaction.
Notification of real-time clinical alerts generated by pharmacy expert systems.
Miller, J. E.; Reichley, R. M.; McNamee, L. A.; Steib, S. A.; Bailey, T. C.
1999-01-01
We developed and implemented a strategy for notifying clinical pharmacists of alerts generated in real-time by two pharmacy expert systems: one for drug dosing and the other for adverse drug event prevention. Display pagers were selected as the preferred notification method and a concise, yet readable, format for displaying alert data was developed. This combination of real-time alert generation and notification via display pagers was shown to be efficient and effective in a 30-day trial. PMID:10566374
An X-ray survey of nine historical novae. [HEAO 2 observations
NASA Technical Reports Server (NTRS)
Becker, R. H.; Marshall, F. E.
1980-01-01
The Einstein Observatory imaging proportional counter was used to search for X-ray emission from nine nearby historical novae. Six of the novae were detected with estimated X-ray intensities between .1 to 4 keV of 10 to the -13th power to 10 to the -11th power ergs/sq cm-s, comparable to the intensities of previously detected cataclysmic variables. The X-ray intensity of one of the novae, V603 Aql, varies over times of several hundred seconds. The data suggest a correlation between the decay rate of the historical outburst and the current X-ray luminosity. Alternatively, the X-ray luminosity may be related to the inclination of the binary system.
NASA Astrophysics Data System (ADS)
Lipunov, V. M.; Blinnikov, S.; Gorbovskoy, E.; Tutukov, A.; Baklanov, P.; Krushinski, V.; Tiurina, N.; Balanutsa, P.; Kuznetsov, A.; Kornilov, V.; Gorbunov, I.; Shumkov, V.; Vladimirov, V.; Gress, O.; Budnev, N. M.; Ivanov, K.; Tlatov, A.; Gabovich, A.; Yurkov, V.; Sergienko, Yu.; Zalozhnykh, I.
2017-09-01
We report the discovery and multicolour (VRIW) photometry of the rare explosive star MASTER OT J004207.99+405501.1 - a luminous red nova - in the Andromeda galaxy M31N2015-01a. We use our original light curve acquired with identical MASTER Global Robotic Net telescopes in one photometric system: VRI during the first 30 d and W (unfiltered) during 70 d. Also, we added published multicolour photometry data to estimate the mass and energy of the ejected shell and we discuss the likely formation scenarios of outbursts of this type. We propose an interpretation of the explosion that is consistent with an evolutionary scenario where the merging of stellar components or the disruption of the common envelope of a close binary can explain some luminous red novae. Radiative hydrodynamic simulations of a luminous red nova were carried out in extended parameter space to fit its light curves. We find that the multicolour passband light curves of the luminous red nova are consistent with an initial common envelope radius of 10 R⊙, a merger mass of 3 M⊙ and an explosion energy of 3 × 1048 erg. As a result, the phenomenon of novae consists of two classes: classical nuclear novae and more rare events (red novae) connected with the loss of compact common envelopes.
New sidescan sonar and gravity evidence that the Nova-Canton Trough is a fracture zone
NASA Astrophysics Data System (ADS)
Joseph, Devorah; Taylor, Brian; Shor, Alexander N.
1992-05-01
A 1990 sidescan sonar survey in the eastern region of the Nova-Canton Trough mapped 138°-striking abyssal-hill fabric trending into 70°-striking trough structures. The location and angle of intersection of the abyssal hills with the eastern Nova-Canton Trough effectively disprove a spreading-center origin of this feature. Free-air gravity anomalies derived from satellite altimetry data show continuity, across the Line Islands, of the Nova-Canton Trough with the Clipperton Fracture Zone. The Canton-Clipperton trend is copolar, about a pole at 30°S, 152°W, with other coeval Pacific-Farallon fracture-zone segments, from the Pau to Marquesas fracture zones. This copolarity leads us to postulate a Pacific-Farallon spreading pattern for the magnetic quiet zone region north and east of the Manihiki Plateau, with the Nova-Canton Trough originating as a transform fault in this system.
Cornu, Pieter; Phansalkar, Shobha; Seger, Diane L; Cho, Insook; Pontefract, Sarah; Robertson, Alexandra; Bates, David W; Slight, Sarah P
2018-03-01
To investigate whether alert warnings for high-priority and low-priority drug-drug interactions (DDIs) were present in five international electronic health record (EHR) systems, to compare and contrast the severity level assigned to them, and to establish the proportion of alerts that were overridden. We conducted a comparative, retrospective, multinational study using a convenience sample of 5 EHRs from the U.S., U.K., Republic of Korea and Belgium. Of the 15 previously defined, high-priority, class-based DDIs, alert warnings were found to exist for 11 in both the Korean and UK systems, 9 in the Belgian system, and all 15 in the two US systems. The specific combinations that were included in these class-based DDIs varied considerably in number, type and level of severity amongst systems. Alerts were only active for 8.4% (52/619) and 52.4% (111/212) of the specific drug-drug combinations contained in the Belgian and UK systems, respectively. Hard stops (not possible to override) existed in the US and UK systems only. The override rates for high-priority alerts requiring provider action ranged from 56.7% to 83.3%. Of the 33 previously defined low-priority DDIs, active alerts existed only in the US systems, for three class-based DDIs. The majority were non-interruptive. Alert warnings existed for most of the high-priority DDIs in the different EHRs but overriding them was easy in most of the systems. In addition to validating the high- and low-priority DDIs, this study reported a lack of standardization in DDI levels across different international knowledge bases. Copyright © 2017. Published by Elsevier B.V.
One vendor's experience: preliminary development of a reminder system based on the Arden Syntax.
Spates, R P; Aller, K C
1994-09-01
This article reviews the efforts of HBO & Company in the production of a first phase clinical alerting system based on the Arden Syntax. The alerting system was integrated with a clinical data repository and clinical workstation to process returning laboratory results. Investigations with expert systems resulted in a C language alerting system. GUI prototyping of an authoring environment led to a Smalltalk language authoring system. Future development is expected to broaden the system scope and address the evolution of the Arden Syntax.
CISN ShakeAlert Earthquake Early Warning System Monitoring Tools
NASA Astrophysics Data System (ADS)
Henson, I. H.; Allen, R. M.; Neuhauser, D. S.
2015-12-01
CISN ShakeAlert is a prototype earthquake early warning system being developed and tested by the California Integrated Seismic Network. The system has recently been expanded to support redundant data processing and communications. It now runs on six machines at three locations with ten Apache ActiveMQ message brokers linking together 18 waveform processors, 12 event association processes and 4 Decision Module alert processes. The system ingests waveform data from about 500 stations and generates many thousands of triggers per day, from which a small portion produce earthquake alerts. We have developed interactive web browser system-monitoring tools that display near real time state-of-health and performance information. This includes station availability, trigger statistics, communication and alert latencies. Connections to regional earthquake catalogs provide a rapid assessment of the Decision Module hypocenter accuracy. Historical performance can be evaluated, including statistics for hypocenter and origin time accuracy and alert time latencies for different time periods, magnitude ranges and geographic regions. For the ElarmS event associator, individual earthquake processing histories can be examined, including details of the transmission and processing latencies associated with individual P-wave triggers. Individual station trigger and latency statistics are available. Detailed information about the ElarmS trigger association process for both alerted events and rejected events is also available. The Google Web Toolkit and Map API have been used to develop interactive web pages that link tabular and geographic information. Statistical analysis is provided by the R-Statistics System linked to a PostgreSQL database.
The Shape of Long Outbursts in U Gem Type Dwarf Novae from AAVSO Data
NASA Technical Reports Server (NTRS)
Cannizzo, John K.
2012-01-01
We search the American Association of Variable Star Observers (AAVSO) archives of the two best studied dwarf novae in an attempt to find light curves for long out bursts that are extremely well-characterized. The systems are U Gem and S8 Cyg. Our goal is to search for embedded precursors such as those that have been found recently in the high fidelity Kepler data for superoutbursts of some members of the 8U UMa subclass of dwarf novae. For the vast majority of AAV80 data, the combination of low data cadence and large errors associated with individual measurements precludes one from making any strong statement about the shape of the long outbursts. However, for a small number of outbursts, extensive long term monitoring with digital photometry yields high fidelity light curves. We report the finding of embedded precursors in two of three candidate long outbursts. This reinforces van Paradijs' finding that long outbursts in dwarf novae above the period gap and superoutbursts in systems below the period gap constitute a unified class. The thermal-tidal instability to account for superoutbursts in the SU UMa stars predicts embedded precursors only for short orbital period dwarf novae, therefore the presence of embedded precursors in long orbital period systems - U Gem and SS Cyg - argues for a more general mechanism to explain long outbursts.
Self-Alert Training: Volitional Modulation of Autonomic Arousal Improves Sustained Attention
ERIC Educational Resources Information Center
O'Connell, Redmond G.; Bellgrove, Mark A.; Dockree, Paul M.; Lau, Adam; Fitzgerald, Michael; Robertson, Ian H.
2008-01-01
The present study examines a new alertness training strategy (Self-Alert Training, SAT) designed to explore the relationship between the top-down control processes governing arousal and sustained attention. In order to maximally target frontal control systems SAT combines a previously validated behavioural self-alerting technique [Robertson, I.…
Wright, Adam; Aaron, Skye; Seger, Diane L; Samal, Lipika; Schiff, Gordon D; Bates, David W
2018-05-15
Drug-drug interaction (DDI) alerts in electronic health records (EHRs) can help prevent adverse drug events, but such alerts are frequently overridden, raising concerns about their clinical usefulness and contribution to alert fatigue. To study the effect of conversion to a commercial EHR on DDI alert and acceptance rates. Two before-and-after studies. 3277 clinicians who received a DDI alert in the outpatient setting. Introduction of a new, commercial EHR and subsequent adjustment of DDI alerting criteria. Alert burden and proportion of alerts accepted. Overall interruptive DDI alert burden increased by a factor of 6 from the legacy EHR to the commercial EHR. The acceptance rate for the most severe alerts fell from 100 to 8.4%, and from 29.3 to 7.5% for medium severity alerts (P < 0.001). After disabling the least severe alerts, total DDI alert burden fell by 50.5%, and acceptance of Tier 1 alerts rose from 9.1 to 12.7% (P < 0.01). Changing from a highly tailored DDI alerting system to a more general one as part of an EHR conversion decreased acceptance of DDI alerts and increased alert burden on users. The decrease in acceptance rates cannot be fully explained by differences in the clinical knowledge base, nor can it be fully explained by alert fatigue associated with increased alert burden. Instead, workflow factors probably predominate, including timing of alerts in the prescribing process, lack of differentiation of more and less severe alerts, and features of how users interact with alerts.
Optical Variability Analysis of UU Aqr - an Eclipsing Nova-like System
NASA Astrophysics Data System (ADS)
Khruzina, T.; Katysheva, N.; Golysheva, P.; Shugarov, S.
2015-12-01
By using our photometric observations of nova-like system UU Aqr with unstable light curve during a few nights, we plotted phase-folded light curves and calculated a model of the system. We show that the complicated character of light curves can be explained by the spiral arms in the disk. We decomposed the syntesis photometric curve into separated components as accretion disk, white and red dwarf, hot line.
Smith, Matthew; Triulzi, Darrell J; Yazer, Mark H; Rollins-Raval, Marian A; Waters, Jonathan H; Raval, Jay S
2014-12-01
Prescriber adherence to institutional blood component ordering guidelines can be low. The goal of this study was to decrease red blood cell (RBC) and plasma orders that did not meet institutional transfusion guidelines by using data within the laboratory information system to trigger alerts in the computerized order entry (CPOE) system at the time of order entry. At 10 hospitals within a regional health care system, discernment rules were created for RBC and plasma orders utilizing transfusion triggers of hemoglobin <8 gm/dl and INR >1.6, respectively, with subsequent alert generation that appears within the CPOE system when a prescriber attempts to order RBCs or plasma on a patient whose antecedent laboratory values do not suggest that a transfusion is indicated. Orders and subsequent alerts were tracked for RBCs and plasma over evaluation periods of 15 and 10 months, respectively, along with the hospital credentials of the ordering health care providers (physician or nurse). Alerts triggered which were heeded remained steady and averaged 11.3% for RBCs and 19.6% for plasma over the evaluation periods. Overall, nurses and physicians canceled statistically identical percentages of alerted RBC (10.9% vs. 11.5%; p = 0.78) and plasma (21.3% vs. 18.7%; p = 0.22) orders. Implementing a simple evidence-based transfusion alert system at the time of order entry decreased non-evidence based transfusion orders by both nurse and physician providers. Copyright © 2014 Elsevier Ltd. All rights reserved.
Warning Alert HITL Experiment Results
NASA Technical Reports Server (NTRS)
Monk, Kevin J.; Ferm, Lisa; Roberts, Zach
2018-01-01
Minimum Operational Performance Standards (MOPS) are being developed to support the integration of Unmanned Aircraft Systems (UAS) in the National Airspace (NAS). Input from subject matter experts and multiple research studies have informed display requirements for Detect-and-Avoid (DAA) systems aimed at supporting timely and appropriate pilot responses to collision hazards. Phase 1 DAA MOPS alerting is designed to inform pilots if an avoidance maneuver is necessary; the two highest alert levels - caution and warning - indicate how soon pilot action is required and whether there is adequate time to coordinate with the air traffic controller (ATC). Additional empirical support is needed to clarify the extent to which warning-level alerting impacts DAA task performance. The present study explores the differential effects of the auditory and visual cues provided by the DAA Warning alert, and performance implications compared to caution-only alerting are discussed.
Tracking the NOvA Detectors' Performance
NASA Astrophysics Data System (ADS)
Psihas, Fernanda; NOvA Collaboration
2016-03-01
The NOvA experiment measures long baseline νμ -->νe oscillations in Fermilab's NuMI beam. We employ two detectors equipped with over 10 thousand sets of data-taking electronics; avalanche photo diodes and front end boards which collect and process the scintillation signal from particle interactions within the detectors. These sets of electronics -as well as the systems which power and cool them- must be monitored and maintained at precise working conditions to ensure maximal data-taking uptime, good data quality and a lasting life for our detectors. This poster describes the automated systems used on NOvA to simultaneously monitor our data quality, diagnose hardware issues, track our performance and coordinate maintenance for the detectors.
Lacson, Ronilda; O'Connor, Stacy D; Sahni, V Anik; Roy, Christopher; Dalal, Anuj; Desai, Sonali; Khorasani, Ramin
2016-07-01
Optimal critical test result communication is a Joint Commission national patient safety goal and requires documentation of closed-loop communication among care providers in the medical record. Electronic alert notification systems can facilitate an auditable process for creating alerts for transmission and acknowledgement of critical test results. We evaluated the impact of a patient safety initiative with an alert notification system on reducing critical results lacking documented communication, and assessed potential overuse of the alerting system for communicating results. We implemented an alert notification system-Alert Notification of Critical Results (ANCR)-in January 2010. We reviewed radiology reports finalised in 2009-2014 which lacked documented communication between the radiologist and another care provider, and assessed the impact of ANCR on the proportion of such reports with critical findings, using trend analysis over 10 semiannual time periods. To evaluate potential overuse of ANCR, we assessed the proportion of reports with non-critical results among provider-communicated reports. The proportion of reports with critical results among reports without documented communication decreased significantly over 4 years (2009-2014) from 0.19 to 0.05 (p<0.0001, Cochran-Armitage trend test). The proportion of provider-communicated reports with non-critical results remained unchanged over time before and after ANCR implementation (0.20 to 0.15, p=0.45, Cochran-Armitage trend test). A patient safety initiative with an alert notification system reduced the proportion of critical results among reports lacking documented communication between care providers. We observed no change in documented communication of non-critical results, suggesting the system did not promote overuse. Future studies are needed to evaluate whether such systems prevent subsequent patient harm. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Leeson, Cory E; Weaver, Robert A; Bissell, Taylor; Hoyer, Rachel; McClain, Corinne; Nelson, Douglas A; Samosky, Joseph T
2012-01-01
We have enhanced a common medical device, the chest tube drainage container, with electronic sensing of fluid volume, automated detection of critical alarm conditions and the ability to automatically send alert text messages to a nurse's cell phone. The PleurAlert system provides a simple touch-screen interface and can graphically display chest tube output over time. Our design augments a device whose basic function dates back 50 years by adding technology to automate and optimize a monitoring process that can be time consuming and inconvenient for nurses. The system may also enhance detection of emergency conditions and speed response time.
NASA Astrophysics Data System (ADS)
Figueira, Joana; José, Jordi; García-Berro, Enrique; Campbell, Simon W.; García-Senz, Domingo; Mohamed, Shazrene
2018-05-01
Context. Classical novae are thermonuclear explosions hosted by accreting white dwarfs in stellar binary systems. Material piles up on top of the white dwarf star under mildly degenerate conditions, driving a thermonuclear runaway. The energy released by the suite of nuclear processes operating at the envelope, mostly proton-capture reactions and β+-decays, heats the material up to peak temperatures ranging from 100 to 400 MK. In these events, about 10-3-10-7 M⊙, enriched in CNO and, sometimes, other intermediate-mass elements (e.g., Ne, Na, Mg, and Al) are ejected into the interstellar medium. Aims: To date, most of the efforts undertaken in the modeling of classical nova outbursts have focused on the early stages of the explosion and ejection, ignoring the interaction of the ejecta, first with the accretion disk orbiting the white dwarf and ultimately with the secondary star. Methods: A suite of 3D, smoothed-particle hydrodynamics (SPH) simulations of the interaction between the nova ejecta, accretion disk, and stellar companion were performed to fill this gap; these simulations were aimed at testing the influence of the model parameters—that is, the mass and velocity of the ejecta, mass and the geometry of the accretion disk—on the dynamical and chemical properties of the system. Results: We discuss the conditions that lead to the disruption of the accretion disk and to mass loss from the binary system. In addition, we discuss the likelihood of chemical contamination of the stellar secondary induced by the impact with the nova ejecta and its potential effect on the next nova cycle. Movies showing the full evolution of several models are available online at http://https://www.aanda.org and at http://www.fen.upc.edu/users/jjose/Downloads.html
Rapid MODIS-based detection of tree cover loss
NASA Astrophysics Data System (ADS)
Wheeler, David; Guzder-Williams, Brook; Petersen, Rachael; Thau, David
2018-07-01
This paper reports on recent improvements made to the FORMA (Hammer et al., 2014a) data product. The resulting system, FORMA250, is a 250-m alerting system updated daily. FORMA250 alerts are available through Global Forest Watch. These alerts can empower law enforcement officials, government agencies responsible for protecting forests, nongovernmental organizations, companies committed to sustainable forest management practices and supply chains, indigenous groups and forest-dependent communities. In addition, the alerts provide useful information for researchers who study temporal and spatial patterns of forest clearing.
Trivett, N. B. A. [Environment Canada, Atmospheric Environment Service, Downsview, Ontario, Canada; Hudec, V. C. [Environment Canada, Atmospheric Environment Service, Downsview, Ontario, Canada; Wong, C. S. [Marine Carbon Research Centre, Institute of Ocean Sciences, Sidney, British Columbia, Canada
1993-01-01
Flask air samples collected at roughly weekly intervals at three Canadian sites [Alert, Northwest Territories (July 1975 through July 1992); Sable Island, Nova Scotia (March 1975 through July 1992); and Cape St. James, British Columbia (May 1979 through July 1992)] were analyzed for CO2 concentration with the measurements directly traceable to the WMO primary CO2 standards. Each record includes the date, atmospheric CO2 concentration, and flask classification code. They provide an accurate record of CO2 concentration levels in Canada during the past two decades. Because these data are directly traceable to WMO standards, this record may be compared with records from other Background Air Pollution Monitoring Network (BAPMoN) stations. The data are in three files (one for each of the monitoring stations) ranging in size from 9.4 to 20.1 kB.
Decision Support Alerts for Medication Ordering in a Computerized Provider Order Entry (CPOE) System
Beccaro, M. A. Del; Villanueva, R.; Knudson, K. M.; Harvey, E. M.; Langle, J. M.; Paul, W.
2010-01-01
Objective We sought to determine the frequency and type of decision support alerts by location and ordering provider role during Computerized Provider Order Entry (CPOE) medication ordering. Using these data we adjusted the decision support tools to reduce the number of alerts. Design Retrospective analyses were performed of dose range checks (DRC), drug-drug interaction and drug-allergy alerts from our electronic medical record. During seven sampling periods (each two weeks long) between April 2006 and October 2008 all alerts in these categories were analyzed. Another audit was performed of all DRC alerts by ordering provider role from November 2008 through January 2009. Medication ordering error counts were obtained from a voluntary error reporting system. Measurement/Results Between April 2006 and October 2008 the percent of medication orders that triggered a dose range alert decreased from 23.9% to 7.4%. The relative risk (RR) for getting an alert was higher at the start of the interventions versus later (RR= 2.40, 95% CI 2.28-2.52; p< 0.0001). The percentage of medication orders that triggered alerts for drug-drug interactions also decreased from 13.5% to 4.8%. The RR for getting a drug interaction alert at the start was 1.63, 95% CI 1.60-1.66; p< 0.0001. Alerts decreased in all clinical areas without an increase in reported medication errors. Conclusion We reduced the quantity of decision support alerts in CPOE using a systematic approach without an increase in reported medication errors PMID:23616845
Masato, Giacomo; Bone, Angie; Charlton-Perez, Andrew; Cavany, Sean; Neal, Robert; Dankers, Rutger; Dacre, Helen; Carmichael, Katie; Murray, Virginia
2015-01-01
Objectives In this study a prototype of a new health forecasting alert system is developed, which is aligned to the approach used in the Met Office’s (MO) National Severe Weather Warning Service (NSWWS). This is in order to improve information available to responders in the health and social care system by linking temperatures more directly to risks of mortality, and developing a system more coherent with other weather alerts. The prototype is compared to the current system in the Cold Weather and Heatwave plans via a case-study approach to verify its potential advantages and shortcomings. Method The prototype health forecasting alert system introduces an “impact vs likelihood matrix” for the health impacts of hot and cold temperatures which is similar to those used operationally for other weather hazards as part of the NSWWS. The impact axis of this matrix is based on existing epidemiological evidence, which shows an increasing relative risk of death at extremes of outdoor temperature beyond a threshold which can be identified epidemiologically. The likelihood axis is based on a probability measure associated with the temperature forecast. The new method is tested for two case studies (one during summer 2013, one during winter 2013), and compared to the performance of the current alert system. Conclusions The prototype shows some clear improvements over the current alert system. It allows for a much greater degree of flexibility, provides more detailed regional information about the health risks associated with periods of extreme temperatures, and is more coherent with other weather alerts which may make it easier for front line responders to use. It will require validation and engagement with stakeholders before it can be considered for use. PMID:26431427
Masato, Giacomo; Bone, Angie; Charlton-Perez, Andrew; Cavany, Sean; Neal, Robert; Dankers, Rutger; Dacre, Helen; Carmichael, Katie; Murray, Virginia
2015-01-01
In this study a prototype of a new health forecasting alert system is developed, which is aligned to the approach used in the Met Office's (MO) National Severe Weather Warning Service (NSWWS). This is in order to improve information available to responders in the health and social care system by linking temperatures more directly to risks of mortality, and developing a system more coherent with other weather alerts. The prototype is compared to the current system in the Cold Weather and Heatwave plans via a case-study approach to verify its potential advantages and shortcomings. The prototype health forecasting alert system introduces an "impact vs likelihood matrix" for the health impacts of hot and cold temperatures which is similar to those used operationally for other weather hazards as part of the NSWWS. The impact axis of this matrix is based on existing epidemiological evidence, which shows an increasing relative risk of death at extremes of outdoor temperature beyond a threshold which can be identified epidemiologically. The likelihood axis is based on a probability measure associated with the temperature forecast. The new method is tested for two case studies (one during summer 2013, one during winter 2013), and compared to the performance of the current alert system. The prototype shows some clear improvements over the current alert system. It allows for a much greater degree of flexibility, provides more detailed regional information about the health risks associated with periods of extreme temperatures, and is more coherent with other weather alerts which may make it easier for front line responders to use. It will require validation and engagement with stakeholders before it can be considered for use.
RZ Leonis Minoris bridging between ER Ursae Majoris-type dwarf nova and nova-like system
NASA Astrophysics Data System (ADS)
Kato, Taichi; Ishioka, Ryoko; Isogai, Keisuke; Kimura, Mariko; Imada, Akira; Miller, Ian; Masumoto, Kazunari; Nishino, Hirochika; Kojiguchi, Naoto; Kawabata, Miho; Sakai, Daisuke; Sugiura, Yuki; Furukawa, Hisami; Yamamura, Kenta; Kobayashi, Hiroshi; Matsumoto, Katsura; Wang, Shiang-Yu; Chou, Yi; Ngeow, Chow-Choong; Chen, Wen-Ping; Panwar, Neelam; Lin, Chi-Sheng; Hsiao, Hsiang-Yao; Guo, Jhen-Kuei; Lin, Chien-Cheng; Omarov, Chingis; Kusakin, Anatoly; Krugov, Maxim; Starkey, Donn R.; Pavlenko, Elena P.; Antonyuk, Kirill A.; Sosnjvskij, Aleksei A.; Antonyuk, Oksana I.; Pit, Nikolai V.; Baklanov, Alex V.; Babina, Julia V.; Itoh, Hiroshi; Padovan, Stefano; Akazawa, Hidehiko; Kafka, Stella; de Miguel, Enrique; Pickard, Roger D.; Kiyota, Seiichiro; Shugarov, Sergey Yu.; Chochol, Drahomir; Krushevska, Viktoriia; Sekeráš, Matej; Pikalova, Olga; Sabo, Richard; Dubovsky, Pavol A.; Kudzej, Igor; Ulowetz, Joseph; Dvorak, Shawn; Stone, Geoff; Tordai, Tamás; Dubois, Franky; Logie, Ludwig; Rau, Steve; Vanaverbeke, Siegfried; Vanmunster, Tonny; Oksanen, Arto; Maeda, Yutaka; Kasai, Kiyoshi; Katysheva, Natalia; Morelle, Etienne; Neustroev, Vitaly V.; Sjoberg, George
2016-12-01
We observed RZ LMi, which is renowned for its extremely short (˜19 d) supercycle and is a member of a small, unusual class of cataclysmic variables called ER UMa-type dwarf novae, in 2013 and 2016. In 2016, the supercycles of this object substantially lengthened in comparison to the previous measurements to 35, 32, and 60 d for three consecutive superoutbursts. We consider that the object virtually experienced a transition to the nova-like state (permanent superhumper). This observed behavior reproduced the prediction of the thermal-tidal instability model extremely well. We detected a precursor in the 2016 superoutburst and detected growing (stage A) superhumps with a mean period of 0.0602(1) d in 2016 and in 2013. Combined with the period of superhumps immediately after the superoutburst, the mass ratio is not as small as in WZ Sge-type dwarf novae, having orbital periods similar to RZ LMi. By using least absolute shrinkage and selection operator (Lasso) two-dimensional power spectra, we detected possible negative superhumps with a period of 0.05710(1) d. We estimated an orbital period of 0.05792 d, which suggests a mass ratio of 0.105(5). This relatively large mass ratio is even above that of ordinary SU UMa-type dwarf novae, and it is also possible that the exceptionally high mass-transfer rate in RZ LMi may be a result of a stripped secondary with an evolved core in a system evolving toward an AM CVn-type object.
Earthquake Early Warning ShakeAlert System: Testing and certification platform
Cochran, Elizabeth S.; Kohler, Monica D.; Given, Douglas; Guiwits, Stephen; Andrews, Jennifer; Meier, Men-Andrin; Ahmad, Mohammad; Henson, Ivan; Hartog, Renate; Smith, Deborah
2017-01-01
Earthquake early warning systems provide warnings to end users of incoming moderate to strong ground shaking from earthquakes. An earthquake early warning system, ShakeAlert, is providing alerts to beta end users in the western United States, specifically California, Oregon, and Washington. An essential aspect of the earthquake early warning system is the development of a framework to test modifications to code to ensure functionality and assess performance. In 2016, a Testing and Certification Platform (TCP) was included in the development of the Production Prototype version of ShakeAlert. The purpose of the TCP is to evaluate the robustness of candidate code that is proposed for deployment on ShakeAlert Production Prototype servers. TCP consists of two main components: a real‐time in situ test that replicates the real‐time production system and an offline playback system to replay test suites. The real‐time tests of system performance assess code optimization and stability. The offline tests comprise a stress test of candidate code to assess if the code is production ready. The test suite includes over 120 events including local, regional, and teleseismic historic earthquakes, recentering and calibration events, and other anomalous and potentially problematic signals. Two assessments of alert performance are conducted. First, point‐source assessments are undertaken to compare magnitude, epicentral location, and origin time with the Advanced National Seismic System Comprehensive Catalog, as well as to evaluate alert latency. Second, we describe assessment of the quality of ground‐motion predictions at end‐user sites by comparing predicted shaking intensities to ShakeMaps for historic events and implement a threshold‐based approach that assesses how often end users initiate the appropriate action, based on their ground‐shaking threshold. TCP has been developed to be a convenient streamlined procedure for objectively testing algorithms, and it has been designed with flexibility to accommodate significant changes in development of new or modified system code. It is expected that the TCP will continue to evolve along with the ShakeAlert system, and the framework we describe here provides one example of how earthquake early warning systems can be evaluated.
The Seismic Alert System of Mexico (SASMEX): Performance and Evolution
NASA Astrophysics Data System (ADS)
Espinosa Aranda, J.
2013-05-01
Originally the Seismic Alert System of Mexico (SASMEX) was proposed to integrate the Seismic Alert System of Mexico City (SAS), operating since 1991, with the Seismic Alert System of Oaxaca City (SASO), in services since 2003. And today, after the intense big earthquake activity observed in our world during 2010 and 2011, local governments of Mexico City, Oaxaca Estate, and the Mexican Ministry of the Interior have been promoting the expansion of this technological EEW development. Until 2012 SASMEX better coverage includes 48 new field seismic sensors (FS) deployed over the seismic region of Jalisco, Colima, Michoacan and Puebla, with someone enhancements over Guerrero and Oaxaca, to reach 97 FS. During 2013, 35 new FS has been proposed to SASMEX enhancements covering the Chiapas and Veracruz seismic regions. The SASMEX, with the support of the Mexico Valley Broadcasters Association (ARVM) since 1993, automatically issue Public and Preventive earthquake early warning signals in the Cities of Mexico, Toluca, Acapulco, Chilpancingo, and Oaxaca. The seismic warning range in each case is seated in accordance with local Civil Protection Authorities: Public Alert, if they expect strong earthquake effects, and Preventive Alert one, the effect could be moderated. Now the SASMEX warning time opportunity could be different to the 60 sec. average typically generated when SAS warned earthquake effects coming from Guerrero to Mexico City valley. Mexican EEW issued today reach: 16 Public and 62 Preventive Alert in Mexico City; 25 Public and 19 Preventive Alerts in Oaxaca City; also 14 Public and 4 Preventive Alerts in Acapulco; 14 Public and 5 Preventive Alerts in Chilpancingo. The earthquakes events registered by SASMEX FS until now reach 3448. With the support of private and Federal telecommunications infrastructure like, TELMEX, Federal Electric Commission, and the Mexican Security Ministry, it was developed a redundant communication system with pads to link the different Cities, trough VHF and UHF radio signals, Fiber Optics, and Satellite technologies, to reach more reliability and availability SASMEX functions and services. To increase the seismic early warning efficiency the Mexico City Historical Center Authorities, promoted the installation of the NOAA VHF radio transmitters system to cover the Mexico City valley, operating with the Specific Area Message Encoding (SAME) called NWR-SAME, and with the Emergency Alert Systems (EAS) protocol of United States. As an enhancement of the NOAA receiver protocol, it was innovated to permit fast Public Alert issue, in no more than 2 sec. The new receiver applied in Mexico is called SARMEX™. Local and federal authorities acquired 90,000 SARMEX™ receivers to be distributed manly in public schools of Mexican cities covered by the SASMEX™ signals; the measure with the aim to promote better natural hazard prevention attitude in the Mexican young population segment.
High Energy Neutrino Physics with NOvA
DOE Office of Scientific and Technical Information (OSTI.GOV)
Coan, Thomas
2016-09-09
Knowledge of the position of energy deposition in “hit” detector cells of the NOvA neutrino detector is required by algorithms for pattern reconstruction and particle identification necessary to interpret the raw data. To increase the accuracy of this process, the majority of NOvA's 350 000 far detector cell shapes, including distortions, were measured as they were constructed. Using a special laser scanning system installed at the site of the NOvA far detector in Ash River, MN, we completed algorithmic development and measured shape parameters for the far detector. The algorithm and the measurements are “published” in NOνA’s document database (docmore » #10389, “Cell Center Finder for the NOνA Far Detector Modules”).« less
Tactical Conflict Detection in Terminal Airspace
NASA Technical Reports Server (NTRS)
Tang, Huabin; Robinson, John E.; Denery, Dallas G.
2010-01-01
Air traffic systems have long relied on automated short-term conflict prediction algorithms to warn controllers of impending conflicts (losses of separation). The complexity of terminal airspace has proven difficult for such systems as it often leads to excessive false alerts. Thus, the legacy system, called Conflict Alert, which provides short-term alerts in both en-route and terminal airspace currently, is often inhibited or degraded in areas where frequent false alerts occur, even though the alerts are provided only when an aircraft is in dangerous proximity of other aircraft. This research investigates how a minimal level of flight intent information may be used to improve short-term conflict detection in terminal airspace such that it can be used by the controller to maintain legal aircraft separation. The flight intent information includes a site-specific nominal arrival route and inferred altitude clearances in addition to the flight plan that includes the RNAV (Area Navigation) departure route. A new tactical conflict detection algorithm is proposed, which uses a single analytic trajectory, determined by the flight intent and the current state information of the aircraft, and includes a complex set of current, dynamic separation standards for terminal airspace to define losses of separation. The new algorithm is compared with an algorithm that imitates a known en-route algorithm and another that imitates Conflict Alert by analysis of false-alert rate and alert lead time with recent real-world data of arrival and departure operations and a large set of operational error cases from Dallas/Fort Worth TRACON (Terminal Radar Approach Control). The new algorithm yielded a false-alert rate of two per hour and an average alert lead time of 38 seconds.
Cecil, Elizabeth; Bottle, Alex; Esmail, Aneez; Wilkinson, Samantha; Vincent, Charles; Aylin, Paul P
2018-05-04
To investigate the association between alerts from a national hospital mortality surveillance system and subsequent trends in relative risk of mortality. There is increasing interest in performance monitoring in the NHS. Since 2007, Imperial College London has generated monthly mortality alerts, based on statistical process control charts and using routinely collected hospital administrative data, for all English acute NHS hospital trusts. The impact of this system has not yet been studied. We investigated alerts sent to Acute National Health Service hospital trusts in England in 2011-2013. We examined risk-adjusted mortality (relative risk) for all monitored diagnosis and procedure groups at a hospital trust level for 12 months prior to an alert and 23 months post alert. We used an interrupted time series design with a 9-month lag to estimate a trend prior to a mortality alert and the change in trend after, using generalised estimating equations. On average there was a 5% monthly increase in relative risk of mortality during the 12 months prior to an alert (95% CI 4% to 5%). Mortality risk fell, on average by 61% (95% CI 56% to 65%), during the 9-month period immediately following an alert, then levelled to a slow decline, reaching on average the level of expected mortality within 18 months of the alert. Our results suggest an association between an alert notification and a reduction in the risk of mortality, although with less lag time than expected. It is difficult to determine any causal association. A proportion of alerts may be triggered by random variation alone and subsequent falls could simply reflect regression to the mean. Findings could also indicate that some hospitals are monitoring their own mortality statistics or other performance information, taking action prior to alert notification. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
NASA Astrophysics Data System (ADS)
Ulutas, E.; Inan, A.; Annunziato, A.
2012-06-01
This study analyzes the response of the Global Disasters Alerts and Coordination System (GDACS) in relation to a case study: the Kepulaunan Mentawai earthquake and related tsunami, which occurred on 25 October 2010. The GDACS, developed by the European Commission Joint Research Center, combines existing web-based disaster information management systems with the aim to alert the international community in case of major disasters. The tsunami simulation system is an integral part of the GDACS. In more detail, the study aims to assess the tsunami hazard on the Mentawai and Sumatra coasts: the tsunami heights and arrival times have been estimated employing three propagation models based on the long wave theory. The analysis was performed in three stages: (1) pre-calculated simulations by using the tsunami scenario database for that region, used by the GDACS system to estimate the alert level; (2) near-real-time simulated tsunami forecasts, automatically performed by the GDACS system whenever a new earthquake is detected by the seismological data providers; and (3) post-event tsunami calculations using GCMT (Global Centroid Moment Tensor) fault mechanism solutions proposed by US Geological Survey (USGS) for this event. The GDACS system estimates the alert level based on the first type of calculations and on that basis sends alert messages to its users; the second type of calculations is available within 30-40 min after the notification of the event but does not change the estimated alert level. The third type of calculations is performed to improve the initial estimations and to have a better understanding of the extent of the possible damage. The automatic alert level for the earthquake was given between Green and Orange Alert, which, in the logic of GDACS, means no need or moderate need of international humanitarian assistance; however, the earthquake generated 3 to 9 m tsunami run-up along southwestern coasts of the Pagai Islands where 431 people died. The post-event calculations indicated medium-high humanitarian impacts.
The Common Alerting Protocol (CAP) adaption in National Early Warning Alerting Systems of China
NASA Astrophysics Data System (ADS)
Li, Chao
2017-04-01
The Common Alerting Protocol (CAP) [1] is an XML-based data format for exchanging public warnings and emergencies between alerting technologies. In China, from local communities to entire nations, there was a patchwork of specialized hazard public alerting systems. And each system was often designed just for certain emergency situations and for certain communications media. Application took place in the NEWAS (National Early Warning Alerting Systems) [2]project where CAP serves as central message to integrate all kind of hazard situations, including the natural calamity, accident disaster, public health emergency , social safety etc. Officially operated on May 2015, NEWAS now has completed docking work with 14 departments including civil administration, safety supervision, forestry, land, water conservancy, earthquake, traffic, meteorology, agriculture, tourism, food and drug supervision, public security and oceanic administration. Thus, several items in CAP has been modified, redefined and extended according to the various grading standards and publishing strategies, as well as the characteristics of Chinese Geocoding. NEWAS successfully delivers information to end users through 4 levels (i.e. State, province, prefecture and county) structure and by various means. [1] CAP, http://www.oasis-emergency.org/cap [2] http://www.12379.cn/
Performance of the NOνA Data Acquisition and Trigger Systems for the full 14 kT Far Detector
NASA Astrophysics Data System (ADS)
Norman, A.; Davies, G. S.; Ding, P. F.; Dukes, E. C.; Duyan, H.; Frank, M. J.; R. C. Group; Habig, A.; Henderson, W.; Niner, E.; Mina, R.; Moren, A.; Mualem, L.; Oksuzian, Y.; Rebel, B.; Shanahan, P.; Sheshukov, A.; Tamsett, M.; Tomsen, K.; Vinton, L.; Wang, Z.; Zamorano, B.; Zirnstien, J.
2015-12-01
The NOvA experiment uses a continuous, free-running, dead-timeless data acquisition system to collect data from the 14 kT far detector. The DAQ system readouts the more than 344,000 detector channels and assembles the information into an raw unfiltered high bandwidth data stream. The NOvA trigger systems operate in parallel to the readout and asynchronously to the primary DAQ readout/event building chain. The data driven triggering systems for NOvA are unique in that they examine long contiguous time windows of the high resolution readout data and enable the detector to be sensitive to a wide range of physics interactions from those with fast, nanosecond scale signals up to processes with long delayed coincidences between hits which occur at the tens of milliseconds time scale. The trigger system is able to achieve a true 100% live time for the detector, making it sensitive to both beam spill related and off-spill physics.
ShakeAlert Users Transition to the Production Prototype System
NASA Astrophysics Data System (ADS)
Strauss, J. A.; Vinci, M.; Steele, W. P.; Hellweg, M.; Allen, R. M.; DeGroot, R. M.
2016-12-01
The ShakeAlert Earthquake Early Warning system transitioned from the demonstration system into the fully-fledged production prototype system this year. Users were migrated over to the new system concurrent with the release of the ShakeAlert UserDisplay Version 2.5.0. The production prototype system provides robust connectivity, fail-over mechanisms to ensure that alarms are deliverd even if one connection fails, and provides a framework to connect future stations, participants, and other sources as the project expands to the full public system. We will present an overview of key user sectors that are either testing or launching pilot projects for the system within their organizations. We will outline the implementation of certain actions, and highlight accomplishments and challenges the Beta Users encounter in fully implementing ShakeAlert within their organizations. By better studying these issues, project partners can better assist the users in incorporating early warning in their operations. Opening up the system to allow for pilot projects enables ShakeAlert users to develop hardware, software, and policy solutions for actions in response to early warning alerts in a controlled environment. This is the first step on the path toward limited rollouts. The pilot groups leverage the expertise of our stakeholders to develop the `last mile' alert distribution and responses. The transition went smoothly in February 2015, for users in California, and we expect to connect with more beta users and pilot groups in this next phase. User transition is planned for Fall 2016 for users in the Pacific Northwest. Beta Users, such as municipalities, emergency response groups, and county officials, lifelines, schools, and private industry continue to meet with ShakeAlert partners to 1) further education and training on both benefits and limitations 2) strategize on implementation actions, such as opening fire house bay doors in response to an alarm, and 3) coordinate continued engagement as the system comes online with more Users and in more areas. The newly created Joint Committee on Communication, Education, and Outreach is aiding with the education and training aspect of the rollout.
An Obstacle Alerting System for Agricultural Application
NASA Technical Reports Server (NTRS)
DeMaio, Joe
2003-01-01
Wire strikes are a significant cause of helicopter accidents. The aircraft most at risk are aerial applicators. The present study examines the effectiveness of a wire alert delivered by way of the lightbar, a GPS-based guidance system for aerial application. The alert lead-time needed to avoid an invisible wire is compared with that to avoid a visible wire. A flight simulator was configured to simulate an agricultural application helicopter. Two pilots flew simulated spray runs in fields with visible wires, invisible wires, and no wires. The wire alert was effective in reducing wire strikes. A lead-time of 3.5 sec was required for the alert to be effective. The lead- time required was the same whether the pilot could see the wire or not.
CISN ShakeAlert: Using early warnings for earthquakes in California
NASA Astrophysics Data System (ADS)
Vinci, M.; Hellweg, M.; Jones, L. M.; Khainovski, O.; Schwartz, K.; Lehrer, D.; Allen, R. M.; Neuhauser, D. S.
2009-12-01
Educated users who have developed response plans and procedures are just as important for an earthquake early warning (EEW) system as are the algorithms and computers that process the data and produce the warnings. In Japan, for example, the implementation of the EEW system which now provides advanced alerts of ground shaking included intense outreach efforts to both institutional and individual recipients. Alerts are now used in automatic control systems that stop trains, place sensitive equipment in safe mode and isolate hazards while the public takes cover. In California, the California Integrated Seismic Network (CISN) is now developing and implementing components of a prototype system for EEW, ShakeAlert. As this processing system is developed, we invite a suite of perspective users from critical industries and institutions throughout California to partner with us in developing useful ShakeAlert products and procedures. At the same time, we will support their efforts to determine and implement appropriate responses to an early warning of earthquake shaking. As a first step, in a collaboration with BART, we have developed a basic system allowing BART’s operation center to receive realtime ground shaking information from more than 150 seismic stations operating in the San Francisco Bay Area. BART engineers are implementing a display system for this information. Later phases will include the development of improved response procedures utilizing this information. We plan to continue this collaboration to include more sophisticated information from the prototype CISN ShakeAlert system.
NASA Technical Reports Server (NTRS)
Chomiuk, Laura; Krauss, Miriam I.; Rupen, Michael P.; Nelson, Thomas; Roy, Nirupam; Sokoloski, Jennifer L.; Mukai, Koji; Munari, Ulisse; Mioduszewski, Amy; Weston, Jeninfer;
2012-01-01
We present multi-frequency radio observations of the 2010 nova event in the symbiotic binary V407 Cygni, obtained with the Karl G. Jansky Very Large Array (VLA) and spanning 1.45 GHz and 17.770 days following discovery. This nova.the first ever detected in gamma rays.shows a radio light curve dominated by the wind of the Mira giant companion, rather than the nova ejecta themselves. The radio luminosity grewas the wind became increasingly ionized by the nova outburst, and faded as the wind was violently heated from within by the nova shock. This study marks the first time that this physical mechanism has been shown to dominate the radio light curve of an astrophysical transient. We do not observe a thermal signature from the nova ejecta or synchrotron emission from the shock, due to the fact that these components were hidden behind the absorbing screen of the Mira wind. We estimate a mass-loss rate for the Mira wind of .Mw approximately equals 10(exp -6) Solar mass yr(exp -1). We also present the only radio detection of V407 Cyg before the 2010 nova, gleaned from unpublished 1993 archival VLA data, which shows that the radio luminosity of the Mira wind varies by a factor of 20 even in quiescence. Although V407 Cyg likely hosts a massive accreting white dwarf, making it a candidate progenitor system for a Type Ia supernova, the dense and radially continuous circumbinary material surrounding V407 Cyg is inconsistent with observational constraints on the environments of most Type Ia supernovae.
Alert Exchange Process Protocol
NASA Technical Reports Server (NTRS)
Groen, Frank
2015-01-01
The National Aeronautics and Space Administration of the United States of America (NASA), and the European Space Agency (ESA), and the Japanese Aerospace Exploration Agency (JAXA), acknowledging that NASA, ESA and JAXA have a mutual interest in exchanging Alerts and Alert Status Lists to enhance the information base for each system participant while fortifying the general level of cooperation between the policy agreement subscribers, and each Party will exchange Alert listings on regular basis and detailed Alert information on a need to know basis to the extent permitted by law.
System and Method for Providing Model-Based Alerting of Spatial Disorientation to a Pilot
NASA Technical Reports Server (NTRS)
Johnson, Steve (Inventor); Conner, Kevin J (Inventor); Mathan, Santosh (Inventor)
2015-01-01
A system and method monitor aircraft state parameters, for example, aircraft movement and flight parameters, applies those inputs to a spatial disorientation model, and makes a prediction of when pilot may become spatially disoriented. Once the system predicts a potentially disoriented pilot, the sensitivity for alerting the pilot to conditions exceeding a threshold can be increased and allow for an earlier alert to mitigate the possibility of an incorrect control input.
Successful ShakeAlert Performance for the Napa Quake
NASA Astrophysics Data System (ADS)
Allen, R. M.; Given, D. D.; Heaton, T. H.; Vidale, J. E.
2014-12-01
ShakeAlert, the demonstration earthquake early warning system, developed by the USGS, UC Berkeley, Caltech, ETH, and the University of Washington, functioned as expected for the August 24, 2014, M6.0 Napa earthquake. The first ShakeAlert was generated by the ElarmS algorithm 5.1 sec after the origin time of the earthquake, and 3.3 sec after the P-wave arrived at the closest station 6.5 km from the epicenter. This initial alert, based on P-wave triggers from four stations, estimated the magnitude to be 5.7. The warning was received at the UC Berkeley Seismological Laboratory 5 seconds before the S-wave and about 10 sec prior to the onset of the strongest shaking. ShakeAlert beta-testers across the San Francisco Bay Area simultaneously received the alert, including the San Francisco 911 center with 8 sec warning, and the BART train system. BART has implemented an automated train-stopping system that was activated (although no trains were running at 3:20 am). With the available network geometry and communications, the blind zone of the first alert had a radius of 16 km. The four stations that contributed to the first alert all encapsulate data into 1-second packets, but the latency in transmitting data to the processing center ranged from 0.27 to 2.62 seconds. If all the stations were to deliver data in 0.27 seconds, then the alert would have been available 2.3 sec sooner and the blind zone would be reduced to about 8 km. This would also mean that the city of Napa would have received about 1 second of warning. The magnitude estimate and event location were accurate from the initial alert onwards. The magnitude estimate did first increase to 5.8 and then dip to 5.4 2.6 sec after the initial alert, stayed at that level for 2 sec, and then returned to 5.7. The final magnitude estimate was 6.0, consistent with the ANSS catalog.
47 CFR 10.410 - Prioritization.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 47 Telecommunication 1 2010-10-01 2010-10-01 false Prioritization. 10.410 Section 10.410 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM Alert Message Requirements § 10.410 Prioritization. A Participating CMS Provider is required to transmit Presidential Alerts...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-04-15
..., cell phones and electronic highway signs. CAP will also allow an alert initiator to send alerts... CAP-formatted alerts delivered via any new delivery systems, whether wireline, internet, satellite, or...
Far Ultraviolet Spectroscopy of Three Long Period Nova-Like Variables, V363 Aur, AC Cnc and RZ Gru
NASA Astrophysics Data System (ADS)
Bisol, Alexandra; Sion, E. M.
2011-01-01
We have selected three nova-like variables: V363 Aur, RZ Gru and AC Cnc, all of which are UX UMa types, having similar orbital periods well beyond the 3 to 4 hour range where most nova-likes are found. All should have very similar secondary stars given the fact that they their physical parameters are so similar. V363 Aur is a bona fide SW Sex star, and AC Cnc is a probable one, while RZ Gru is not a member of the SW Sex subclass. Our objective is to carry out the first synthetic spectral analysis of far ultraviolet spectra of the three systems using state-of-the-art models both of accretion disks and photospheres. Therefore we shall compare the distances we obtain from the best fitting synthetic spectral models to other distance estimates in the literature. We present model-derived accretion rates and distances for all three systems. The FUV flux range of RZ Gru and V363 Aur is dominated by radiation from an optically thick, steady state, accretion but for AC Cnc, we find that a hot white dwarf accounts for 70% of the FUV flux. We compare the FUV characteristics and physical properties of these three long period nova-like systems to the properties of other nova-likes at shorter periods. This work was supported in part by NSF grant AST0807892 to Villanova University.
NASA Technical Reports Server (NTRS)
Shore, S.N.; Genovali, K.; Wahlgren, G. M.
2013-01-01
We present some results of an ongoing study of the long-term spectroscopic variations of AG Dra, a prototypical eruptive symbiotic system. We discuss the effects of the environment and orbital modulation in this system and some of the physical processes revealed by a comparison with the nova outburst of the symbiotic-like recurrent nova V407 Cyg 2010.
Pfeiffer, Yvonne; Schwappach, David
2016-01-01
National safety alert systems publish relevant information to improve patient safety in hospitals. However, the information has to be transformed into local action to have an effect on patient safety. We studied three research questions: How do Swiss healthcare quality and risk managers (qm/rm(1)) see their own role in learning from safety alerts issued by the Swiss national voluntary reporting and analysis system? What are their attitudes towards and evaluations of the alerts, and which types of improvement actions were fostered by the safety alerts? A survey was developed and applied to Swiss healthcare risk and quality managers, with a response rate of 39 % (n=116). Descriptive statistics are presented. The qm/rm disseminate and communicate with a broad variety of professional groups about the alerts. While most respondents felt that they should know the alerts and their contents, only a part of them felt responsible for driving organizational change based on the recommendations. However, most respondents used safety alerts to back up their own patient safety goals. The alerts were evaluated positively on various dimensions such as usefulness and were considered as standards of good practice by the majority of the respondents. A range of organizational responses was applied, with disseminating information being the most common. An active role is related to using safety alerts for backing up own patient safety goals. To support an active role of qm/rm in their hospital's learning from safety alerts, appropriate organizational structures should be developed. Furthermore, they could be given special information or training to act as an information hub on the issues discussed in the alerts. Copyright © 2016. Published by Elsevier GmbH.
Hoffman, Keith B; Demakas, Andrea R; Dimbil, Mo; Tatonetti, Nicholas P; Erdman, Colin B
2014-11-01
The US Food and Drug Administration (FDA) uses the Adverse Event Reporting System (FAERS) to support post-marketing safety surveillance programs. Currently, almost one million case reports are submitted to FAERS each year, making it a vast repository of drug safety information. Sometimes cited as a limitation of FAERS, however, is the assumption that "stimulated reporting" of adverse events (AEs) occurs in response to warnings, alerts, and label changes that are issued by the FDA. To determine the extent of "stimulated reporting" in the modern-day FAERS database. One hundred drugs approved by the FDA between 2001 and 2010 were included in this analysis. FDA alerts were obtained by a comprehensive search of the FDA's MedWatch and main websites. Publicly available FAERS data were used to assess the "primary suspect" AE reporting pattern for up to four quarters before, and after, the issuance of an FDA alert. A few drugs did demonstrate "stimulated reporting" trends. A majority of the drugs, however, showed little evidence for significant reporting changes associated with the issuance of alerts. When we compared the percentage changes in reporting after an FDA alert with those after a sham "control alert", the overall reporting trends appeared to be quite similar. Of 100 drugs analyzed for short-term reporting trends, 21 real alerts and 25 sham alerts demonstrated an increase (greater than or equal to 1 %) in reporting. The long-term analysis of 91 drugs showed that 24 real alerts and 28 sham alerts demonstrated a greater than or equal to 1 % increase. Our results suggest that most of modern day FAERS reporting is not significantly affected by the issuance of FDA alerts.
Reducing duplicate testing: a comparison of two clinical decision support tools.
Procop, Gary W; Keating, Catherine; Stagno, Paul; Kottke-Marchant, Kandice; Partin, Mary; Tuttle, Robert; Wyllie, Robert
2015-05-01
Unnecessary duplicate laboratory testing is common and costly. Systems-based means to avert unnecessary testing should be investigated and employed. We compared the effectiveness and cost savings associated with two clinical decision support tools to stop duplicate testing. The Hard Stop required telephone contact with the laboratory and justification to have the duplicate test performed, whereas the Smart Alert allowed the provider to bypass the alert at the point of order entry without justification. The Hard Stop alert was significantly more effective than the Smart Alert (92.3% vs 42.6%, respectively; P < .0001). The cost savings realized per alert activation was $16.08/alert for the Hard Stop alert vs $3.52/alert for the Smart Alert. Structural and process changes that require laboratory contact and justification for duplicate testing are more effective than interventions that allow providers to bypass alerts without justification at point of computerized physician order entry. Copyright© by the American Society for Clinical Pathology.
Recent evolution of the offline computing model of the NOvA experiment
Habig, Alec; Norman, A.; Group, Craig
2015-12-23
The NOvA experiment at Fermilab is a long-baseline neutrino experiment designed to study ν e appearance in a ν μ beam. Over the last few years there has been intense work to streamline the computing infrastructure in preparation for data, which started to flow in from the far detector in Fall 2013. Major accomplishments for this effort include migration to the use of off-site resources through the use of the Open Science Grid and upgrading the file-handling framework from simple disk storage to a tiered system using a comprehensive data management and delivery system to find and access files onmore » either disk or tape storage. NOvA has already produced more than 6.5 million files and more than 1 PB of raw data and Monte Carlo simulation files which are managed under this model. In addition, the current system has demonstrated sustained rates of up to 1 TB/hour of file transfer by the data handling system. NOvA pioneered the use of new tools and this paved the way for their use by other Intensity Frontier experiments at Fermilab. Most importantly, the new framework places the experiment's infrastructure on a firm foundation, and is ready to produce the files needed for first physics.« less
Recent Evolution of the Offline Computing Model of the NOvA Experiment
NASA Astrophysics Data System (ADS)
Habig, Alec; Norman, A.
2015-12-01
The NOvA experiment at Fermilab is a long-baseline neutrino experiment designed to study νe appearance in a νμ beam. Over the last few years there has been intense work to streamline the computing infrastructure in preparation for data, which started to flow in from the far detector in Fall 2013. Major accomplishments for this effort include migration to the use of off-site resources through the use of the Open Science Grid and upgrading the file-handling framework from simple disk storage to a tiered system using a comprehensive data management and delivery system to find and access files on either disk or tape storage. NOvA has already produced more than 6.5 million files and more than 1 PB of raw data and Monte Carlo simulation files which are managed under this model. The current system has demonstrated sustained rates of up to 1 TB/hour of file transfer by the data handling system. NOvA pioneered the use of new tools and this paved the way for their use by other Intensity Frontier experiments at Fermilab. Most importantly, the new framework places the experiment's infrastructure on a firm foundation, and is ready to produce the files needed for first physics.
Slow magnetic monopoles search in NOvA
NASA Astrophysics Data System (ADS)
Antoshkin, Alexander; Frank, Martin
2018-04-01
The NOvA far detector is well suited for finding exotic particles due to its technical features (see [1]). One type of those exotic particles is a "slow" magnetic monopole. It is assumed that the energy deposition of such monopoles should be enough to be registered (see [2]). Measurement of the expected signals was performed on the NOvA test bench at JINR (see [3]). Result of this measurement allows us to perform slow monopole's research using NOvA software and hardware with high efficiency. As a whole, the research can lead to a discovery, or it can limit the existence of monopoles in a wide range of parameters, previously unreachable in other experiments (MACRO, SLIM, RICE, IceCube). Several special software tools have been developed. Slow Monopole Trigger has been created and implemented in the NOvA Data-Driven-Trigger system. Also, an online reconstruction algorithm has been developed and tested on 5% of the data. A technical description of these tools and current results of the analysis are presented in this work.
Synthetic Spectral Analysis of the Far Ultraviolet Spectra of the Old Nova HR Del
NASA Astrophysics Data System (ADS)
Robertson, Jordan; Sion, E.
2012-05-01
We present a synthetic spectral analysis of the archival IUE far ultraviolet spectra of the post-nova, HR Del (Nova Del 1967). The system has an estimated white dwarf mass of 0.55 Msun (Ritter and Kolb 2003), orbital period P_orb = 0.214165 days, estimated orbital inclination of 40 degrees (Keurster 1988) and distance determinations in the literature ranging from 970 pc to 285 pc. The spectra reveal P Cygni profiles indicative of wind outflow from the disk and closely resemble the IUE spectra of UX UMa nova-likes, which have never had recorded outbursts. We de-reddened the archival IUE spectra using E(B-V) = 0.16. Our synthetic spectral analysis utilized optically thick, steady state accretion disk models and white dwarf model atmospheres that we constructed using TLUSTY and SYNSPEC (Hubeny 1988, Hubeny and Lanz (1995). Our input parameters were the white dwarf mass, inclination and a range of accretion rates for which we found the best-fitting model. We report the results of our model fitting and compare HR Del with other post-novae at comparable times past their nova outburst. This work was supported by NSF grant 0807892 to Villanova University
NASA Technical Reports Server (NTRS)
Ladous, Constanze
1993-01-01
Dwarf novae are defined on grounds of their semi-regular brightness variations of some two to five magnitudes on time scales of typically 10 to 100 days. Historically several different classification schemes have been used. Today, dwarf novae are divided into three sub-classes: the U Geminorum stars, the SU Ursae Majoris stars, and the Z Camelopardalis stars. Outbursts of dwarf novae occur at semi-periodic intervals of time, typically every 10 to 100 days; amplitudes range from typically 2 to 5 mag. Within certain limits values are characteristic for each object. Relations between the outburst amplitude, or the total energy released during outburst, and the recurrence time have been found, as well as relations between the orbital period and the outburst decay time, the absolute magnitude during outburst maximum, and the widths of long and short outbursts, respectively. Some dwarf novae are known to have suspended their normal outburst activity altogether for a while. They later resumed it without having undergone any observable changes. The optical colors of dwarf novae all are quite similar during outburst, considerably bluer than during the quiescent state. During the outburst cycle, characteristic loops in the two color diagram are performed. At a time resolution on the order of minutes, strictly periodic photometric changes due to orbital motion become visible in the light curves of dwarf novae. These are characteristic for each system. Remarkably little is known about orbital variations during the course of an outburst. On time-scales of minutes and seconds, further more or less periodic types of variability are seen in dwarf novae. Appreciable flux is emitted by dwarf novae at all wavelengths from the X-rays to the longest IR wavelengths, and in some cases even in the radio. Most dwarf novae exhibit strong emission line spectra in the optical and UV during quiescence, although some have only very weak emissions in the optical and/or weak absorptions at UV wavelengths.
Cockpit display of hazardous weather information
NASA Technical Reports Server (NTRS)
Hansman, R. John, Jr.; Wanke, Craig
1991-01-01
Information transfer and display issues associated with the dissemination of hazardous weather warnings are studied in the context of wind shear alerts. Operational and developmental wind shear detection systems are briefly reviewed. The July 11, 1988 microburst events observed as part of the Denver Terminal Doppler Weather Radar (TDWR) operational evaluation are analyzed in terms of information transfer and the effectiveness of the microburst alerts. Information transfer, message content and display issues associated with microburst alerts generated from ground based sources (Doppler Radar, Low Level Wind Shear Alert System, and Pilot Reports) are evaluated by means fo pilot opinion surveys and part task simulator studies.
Phansalkar, Shobha; Zachariah, Marianne; Seidling, Hanna M; Mendes, Chantal; Volk, Lynn; Bates, David W
2014-01-01
Introduction Increasing the adoption of electronic health records (EHRs) with integrated clinical decision support (CDS) is a key initiative of the current US healthcare administration. High over-ride rates of CDS alerts strongly limit these potential benefits. As a result, EHR designers aspire to improve alert design to achieve better acceptance rates. In this study, we evaluated drug–drug interaction (DDI) alerts generated in EHRs and compared them for compliance with human factors principles. Methods We utilized a previously validated questionnaire, the I-MeDeSA, to assess compliance with nine human factors principles of DDI alerts generated in 14 EHRs. Two reviewers independently assigned scores evaluating the human factors characteristics of each EHR. Rankings were assigned based on these scores and recommendations for appropriate alert design were derived. Results The 14 EHRs evaluated in this study received scores ranging from 8 to 18.33, with a maximum possible score of 26. Cohen's κ (κ=0.86) reflected excellent agreement among reviewers. The six vendor products tied for second and third place rankings, while the top system and bottom five systems were home-grown products. The most common weaknesses included the absence of characteristics such as alert prioritization, clear and concise alert messages indicating interacting drugs, actions for clinical management, and a statement indicating the consequences of over-riding the alert. Conclusions We provided detailed analyses of the human factors principles which were assessed and described our recommendations for effective alert design. Future studies should assess whether adherence to these recommendations can improve alert acceptance. PMID:24780721
Clinical Decision Support Alert Appropriateness: A Review and Proposal for Improvement
McCoy, Allison B.; Thomas, Eric J.; Krousel-Wood, Marie; Sittig, Dean F.
2014-01-01
Background Many healthcare providers are adopting clinical decision support (CDS) systems to improve patient safety and meet meaningful use requirements. Computerized alerts that prompt clinicians about drug-allergy, drug-drug, and drug-disease warnings or provide dosing guidance are most commonly implemented. Alert overrides, which occur when clinicians do not follow the guidance presented by the alert, can hinder improved patient outcomes. Methods We present a review of CDS alerts and describe a proposal to develop novel methods for evaluating and improving CDS alerts that builds upon traditional informatics approaches. Our proposal incorporates previously described models for predicting alert overrides that utilize retrospective chart review to determine which alerts are clinically relevant and which overrides are justifiable. Results Despite increasing implementations of CDS alerts, detailed evaluations rarely occur because of the extensive labor involved in manual chart reviews to determine alert and response appropriateness. Further, most studies have solely evaluated alert overrides that are appropriate or justifiable. Our proposal expands the use of web-based monitoring tools with an interactive dashboard for evaluating CDS alert and response appropriateness that incorporates the predictive models. The dashboard provides 2 views, an alert detail view and a patient detail view, to provide a full history of alerts and help put the patient's events in context. Conclusion The proposed research introduces several innovations to address the challenges and gaps in alert evaluations. This research can transform alert evaluation processes across healthcare settings, leading to improved CDS, reduced alert fatigue, and increased patient safety. PMID:24940129
Miyake, Noriko; Chong, Yong; Nishida, Ruriko; Nagasaki, Yoji; Kibe, Yasushi; Kiyosuke, Makiko; Shimomura, Takeshi; Shimono, Nobuyuki; Shimoda, Shinji; Akashi, Koichi
2015-11-01
In our hospital, positive blood culture rates of Helicobacter cinaedi dramatically increased after introducing the Bactec system. A simulated culture model of H. cinaedi bacteremia demonstrated no positive signals using the BacT/Alert system, despite efficient growth in bottles. Clinically suspected H. cinaedi bacteremia should be monitored more closely when using the BacT/Alert system, preferably with subcultivation after 7days of incubation. Copyright © 2015 Elsevier Inc. All rights reserved.
A new method for determining a sector alert
DOT National Transportation Integrated Search
2008-09-29
The Traffic Flow Management System (TFMS) currently declares an alert for any 15-minute interval in which the predicted demand exceeds the Monitor/Alert Parameter (MAP) for any airport, sector, or fix. For a sector, TFMS predicts the demand for each ...
A new approach to monitoring and alerting congestion in airspace sectors
DOT National Transportation Integrated Search
2014-09-28
The Federal Aviation Administration (FAA) Traffic Flow Management System (TFMS)currently declares an alert for any 15 minute interval in which the predicted demand exceeds the Monitor/Alert Parameter (MAP)for any airport, sector, or fix. For airports...
Wide variation and patterns of physicians' responses to drug-drug interaction alerts.
Cho, Insook; Lee, Yura; Lee, Jae-Ho; Bates, David W
2018-05-08
Providing physicians with alerts about potentially harmful drug-drug interactions (DDIs) is only moderately effective due to high alert override rates. To understand high override behavior on DDI alerts, we investigated how physicians respond to DDIs and their behavior patterns and variations. Retrospective system log data analysis and records review (sampling 2% of total overrides). A large tertiary academic hospital. About 560 physicians and their override responses to DDI alerts generated from 1 September to 31 December 2014. Not applicable. DDI alert frequency and override rate. We found significant variation in both the number of alerts and override rates at the levels of physicians, departments and drug-class pairs. Physician-level variations were wider for residents than for faculty staff (number of alerts: t = 254.17, P = 0.011; override rates: t = -4.77, P < 0.0001). Using the number of alerts and their override rate, we classified physicians into four groups: inexperienced incautious users, inexperienced cautious users, experienced cautious users and experienced incautious users. Medical department influenced both alert numbers and override rates. Nearly 90% of the overrides involved only five drug-class combinations, which had a wide range of appropriateness in the chart review. The variations at drug-class levels suggest issues with system design and the DDI rules. Department-level variation may be best addressed at the department level, and the rest of the variation appears related to individual physician responses, suggesting the need for interventions at an individual level.
Typical examples of classical novae
NASA Technical Reports Server (NTRS)
Hack, Margherita; Selvelli, Pierluigi; Bianchini, Antonio; Duerbeck, Hilmar W.
1993-01-01
Because of the very complicated individualistic behavior of each nova, we think it necessary to review the observations of a few well-observed individuals. We have selected a few objects of different speed classes, which have been extensively observed. They are: V1500 Cygni 1975, a very fast nova; V603 Aql 1918, fast nova; CP Pup 1942, fast nova; GK Per 1901, fast nova; V 1668 Cyg 1979, moderately fast nova; FH Ser 1970, slow nova; DQ Her 1934, slow nova; T Aur 1891, slow nova; RR Pic 1925, slow nova; and HR Del 1967, very slow nova.
Typical examples of classical novae
NASA Astrophysics Data System (ADS)
Hack, Margherita; Selvelli, Pierluigi; Bianchini, Antonio; Duerbeck, Hilmar W.
1993-09-01
Because of the very complicated individualistic behavior of each nova, we think it necessary to review the observations of a few well-observed individuals. We have selected a few objects of different speed classes, which have been extensively observed. They are: V1500 Cygni 1975, a very fast nova; V603 Aql 1918, fast nova; CP Pup 1942, fast nova; GK Per 1901, fast nova; V 1668 Cyg 1979, moderately fast nova; FH Ser 1970, slow nova; DQ Her 1934, slow nova; T Aur 1891, slow nova; RR Pic 1925, slow nova; and HR Del 1967, very slow nova.
Cooke, Charmaine; Nissen, Lisa; Sketris, Ingrid; Tett, Susan E
2005-04-01
Jurisdictions are developing public drug insurance systems to improve access to pharmaceuticals, cost-effective prescribing, and patient health and well-being. We compared 2 jurisdictions with different pharmaceutical policies to determine prescribing patterns for 3-hydroxy-3-methylglutaryl coenzyme A reductase inhibitors (ie, statins). The aim of this work was to investigate the feasibility of using available prescription administrative databases to compare the use of statins in Queensland, Australia, and in Nova Scotia, Canada. Data from the Nova Scotia Pharmacare Program and the Health Insurance Commission in Australia were used to obtain dispensing data. Utilization was compared for the 5-year period from 1997 through 2001, using the World Health Organization anatomic therapeutic chemical/defined daily dose (DDD) system. In the year 2001, there were 177,000 beneficiaries in the public drug plan in Nova Scotia (62% aged > or = 65 years old) and 960,000 concession beneficiaries (pensioners and social security recipients, 61 aged > or = 65 years) in Queensland. These 2 groups were comparable. The overall utilization of statin medications increased steadily in both areas over the study period, from 50 to 205 DDD/1000 beneficiaries per day. Comparison of the 2 growth lines showed no statistically significant differences in overall statin use despite differences in brand availabilities and policies about prescribing. In the year 2001, atorvastatin was the most commonly prescribed statin in both areas, comprising 46% of statin use in Nova Scotia and 51% in Queensland. Mean doses of each statin prescribed were slightly above the DDDs. Expenditure on statins per 1000 beneficiaries and per DDD were similar in each jurisdiction, being slightly higher in Nova Scotia. Despite differences in pharmaceutical reimbursement systems, use of the statins was similar in Nova Scotia and Queensland. The feasibility of the methodology was demonstrated. Future studies, including comparisons of drug utilization for other classes of drugs for which drug policies may be divergent (eg, different pricing structures or prior authorization requirements), or for which less evidence for appropriate use is available, may be useful.
Research activities in nuclear astrophysics and related areas
NASA Technical Reports Server (NTRS)
1996-01-01
NASA/GRO grant NAG 5-2081, at the University of Chicago, has provided support for a broad program of theoretical research in nuclear astrophysics and related areas, with regard to gamma-ray and hard X-ray emission from classical nova explosions. This research emphasized the possible detection of 22Na gamma-ray line emission from nearby novae involving ONeMg white dwarfs, the detailed examination of 26Al production in novae, and the possible detection of the predicted early gamma ray emission from novae that arises from the decay of the short lived, positron emitting isotopes of CNO elements. Studies of nova related problems have consumed an increasing fraction of the Principal Investigator's research efforts over the past decade. Current research addresses problems associated with the standard model for the outbursts of the classical novae: the occurrence of thermonuclear runaways (TNR) in the accreted hydrogen rich envelopes on white dwarfs in close binary systems (see, e.g., the reviews by Truran 1982; and Shara 1989). Research in progress and planned for the next three years has three main objectives: (1) to gain an improved understanding of the early evolution of the light curves of, particularly, the fastest novae; (2) to gain an improved understanding of the relative importance of the various possible mechanisms of envelope hydrogen depletion (e.g. winds, common envelope driven mass loss, and nuclear burning) to the long term evolution of novae in outburst; and (3) to seek to provide a somewhat more definitive statement of the role of classical novae in nucleosynthesis. Our proposed 2-D studies of convection during the early phases of the TNR and our systematic attempt to incorporate an improved treatment of radiation hydrodynamics into the hydrodynamic code utilized in our calculations, are particularly relevant to the first of these objectives. Further 2-D studies of the effects of common envelope evolution are intended to provide more realistic constraints on the mass depletion mechanisms. Finally, detailed calculations of the thermonuclear history of the matter ejected in novae will be carried out for representative nova configurations involving both carbon-oxygen (CO) and oxygen-neon-magnesium (ONeMg) white dwarfs.
Santa-Olalla, Patricia; Gayer, Michelle; Magloire, Roc; Barrais, Robert; Valenciano, Marta; Aramburu, Carmen; Poncelet, Jean Luc; Gustavo Alonso, Juan Carlos; Van Alphen, Dana; Heuschen, Florence; Andraghetti, Roberta; Lee, Robert; Drury, Patrick; Aldighieri, Sylvain
2013-01-01
The start of the cholera epidemic in Haiti quickly highlighted the necessity of the implementation of an Alert and Response (A&R) System to complement the existing national surveillance system. The national system had been able to detect and confirm the outbreak etiology but required external support to monitor the spread of cholera and coordinate response, because much of the information produced was insufficiently timely for real-time monitoring and directing of a rapid, targeted response. The A&R System was designed by the Pan American Health Organization/World Health Organization in collaboration with the Haiti Ministry of Health, and it was based on a network of partners, including any institution, structure, or individual that could identify, verify, and respond to alerts. The defined objectives were to (1) save lives through early detection and treatment of cases and (2) control the spread through early intervention at the community level. The operational structure could be broken down into three principle categories: (1) alert (early warning), (2) verification and assessment of the information, and (3) efficient and timely response in coordination with partners to avoid duplication. Information generated by the A&R System was analyzed and interpreted, and the qualitative information was critical in qualifying the epidemic and defining vulnerable areas, particularly because the national surveillance system reported incomplete data for more than one department. The A&R System detected a number of alerts unrelated to cholera and facilitated rapid access to that information. The sensitivity of the system and its ability to react quickly was shown in May of 2011, when an abnormal increase in alerts coming from several communes in the Sud-Est Department in epidemiological weeks (EWs) 17 and 18 were noted and disseminated network-wide and response activities were implemented. The national cholera surveillance system did not register the increase until EWs 21 and 22, and the information did not become available until EWs 23 and 24, when the peak of cases had already been reached. Although many of the partners reporting alerts during the peak of the cholera epidemic have since left Haiti, the A&R System has continued to function as an Early Warning (EWARN) System, and it continues to be developed with recent activities, such as the distribution of cell phones to enhance alert communication. PMID:24106196
Santa-Olalla, Patricia; Gayer, Michelle; Magloire, Roc; Barrais, Robert; Valenciano, Marta; Aramburu, Carmen; Poncelet, Jean Luc; Gustavo Alonso, Juan Carlos; Van Alphen, Dana; Heuschen, Florence; Andraghetti, Roberta; Lee, Robert; Drury, Patrick; Aldighieri, Sylvain
2013-10-01
The start of the cholera epidemic in Haiti quickly highlighted the necessity of the implementation of an Alert and Response (A&R) System to complement the existing national surveillance system. The national system had been able to detect and confirm the outbreak etiology but required external support to monitor the spread of cholera and coordinate response, because much of the information produced was insufficiently timely for real-time monitoring and directing of a rapid, targeted response. The A&R System was designed by the Pan American Health Organization/World Health Organization in collaboration with the Haiti Ministry of Health, and it was based on a network of partners, including any institution, structure, or individual that could identify, verify, and respond to alerts. The defined objectives were to (1) save lives through early detection and treatment of cases and (2) control the spread through early intervention at the community level. The operational structure could be broken down into three principle categories: (1) alert (early warning), (2) verification and assessment of the information, and (3) efficient and timely response in coordination with partners to avoid duplication. Information generated by the A&R System was analyzed and interpreted, and the qualitative information was critical in qualifying the epidemic and defining vulnerable areas, particularly because the national surveillance system reported incomplete data for more than one department. The A&R System detected a number of alerts unrelated to cholera and facilitated rapid access to that information. The sensitivity of the system and its ability to react quickly was shown in May of 2011, when an abnormal increase in alerts coming from several communes in the Sud-Est Department in epidemiological weeks (EWs) 17 and 18 were noted and disseminated network-wide and response activities were implemented. The national cholera surveillance system did not register the increase until EWs 21 and 22, and the information did not become available until EWs 23 and 24, when the peak of cases had already been reached. Although many of the partners reporting alerts during the peak of the cholera epidemic have since left Haiti, the A&R System has continued to function as an Early Warning (EWARN) System, and it continues to be developed with recent activities, such as the distribution of cell phones to enhance alert communication.
Validation of the CME Geomagnetic Forecast Alerts Under the COMESEP Alert System
NASA Astrophysics Data System (ADS)
Dumbović, Mateja; Srivastava, Nandita; Rao, Yamini K.; Vršnak, Bojan; Devos, Andy; Rodriguez, Luciano
2017-08-01
Under the European Union 7th Framework Programme (EU FP7) project Coronal Mass Ejections and Solar Energetic Particles (COMESEP, http://comesep.aeronomy.be), an automated space weather alert system has been developed to forecast solar energetic particles (SEP) and coronal mass ejection (CME) risk levels at Earth. The COMESEP alert system uses the automated detection tool called Computer Aided CME Tracking (CACTus) to detect potentially threatening CMEs, a drag-based model (DBM) to predict their arrival, and a CME geoeffectiveness tool (CGFT) to predict their geomagnetic impact. Whenever CACTus detects a halo or partial halo CME and issues an alert, the DBM calculates its arrival time at Earth and the CGFT calculates its geomagnetic risk level. The geomagnetic risk level is calculated based on an estimation of the CME arrival probability and its likely geoeffectiveness, as well as an estimate of the geomagnetic storm duration. We present the evaluation of the CME risk level forecast with the COMESEP alert system based on a study of geoeffective CMEs observed during 2014. The validation of the forecast tool is made by comparing the forecasts with observations. In addition, we test the success rate of the automatic forecasts (without human intervention) against the forecasts with human intervention using advanced versions of the DBM and CGFT (independent tools available at the Hvar Observatory website, http://oh.geof.unizg.hr). The results indicate that the success rate of the forecast in its current form is unacceptably low for a realistic operation system. Human intervention improves the forecast, but the false-alarm rate remains unacceptably high. We discuss these results and their implications for possible improvement of the COMESEP alert system.
The Distance to Nova V959 Mon from VLA Imaging
NASA Astrophysics Data System (ADS)
Linford, J. D.; Ribeiro, V. A. R. M.; Chomiuk, L.; Nelson, T.; Sokoloski, J. L.; Rupen, M. P.; Mukai, K.; O'Brien, T. J.; Mioduszewski, A. J.; Weston, J.
2015-06-01
Determining reliable distances to classical novae is a challenging but crucial step in deriving their ejected masses and explosion energetics. Here we combine radio expansion measurements from the Karl G. Jansky Very Large Array with velocities derived from optical spectra to estimate an expansion parallax for nova V959 Mon, the first nova discovered through its γ-ray emission. We spatially resolve the nova at frequencies of 4.5-36.5 GHz in nine different imaging epochs. The first five epochs cover the expansion of the ejecta from 2012 October to 2013 January, while the final four epochs span 2014 February-May. These observations correspond to days 126 through 199 and days 615 through 703 after the first detection of the nova. The images clearly show a non-spherical ejecta geometry. Utilizing ejecta velocities derived from three-dimensional modeling of optical spectroscopy, the radio expansion implies a distance between 0.9 ± 0.2 and 2.2 ± 0.4 kpc, with a most probable distance of 1.4 ± 0.4 kpc. This distance implies a γ-ray luminosity of 0.6× {{10}35} erg s-1, which is much less than the prototype γ-ray-detected nova, V407 Cyg, possibly due to the lack of a red giant companion in the V959 Mon system. V959 Mon also has a much lower γ-ray luminosity than other classical novae detected in γ-rays to date, indicating a range of at least a factor of 10 in the γ-ray luminosities for these explosions.
Human Factors Evaluation of Conflict Detection Tool for Terminal Area
NASA Technical Reports Server (NTRS)
Verma, Savita Arora; Tang, Huabin; Ballinger, Deborah; Chinn, Fay Cherie; Kozon, Thomas E.
2013-01-01
A conflict detection and resolution tool, Terminal-area Tactical Separation-Assured Flight Environment (T-TSAFE), is being developed to improve the timeliness and accuracy of alerts and reduce the false alert rate observed with the currently deployed technology. The legacy system in use today, Conflict Alert, relies primarily on a dead reckoning algorithm, whereas T-TSAFE uses intent information to augment dead reckoning. In previous experiments, T-TSAFE was found to reduce the rate of false alerts and increase time between the alert to the controller and a loss of separation over the legacy system. In the present study, T-TSAFE was tested under two meteorological conditions, 1) all aircraft operated under instrument flight regimen, and 2) some aircraft operated under mixed operating conditions. The tool was used to visually alert controllers to predicted Losses of separation throughout the terminal airspace, and show compression errors, on final approach. The performance of T-TSAFE on final approach was compared with Automated Terminal Proximity Alert (ATPA), a tool recently deployed by the FAA. Results show that controllers did not report differences in workload or situational awareness between the T-TSAFE and ATPA cones but did prefer T-TSAFE features over ATPA functionality. T-TSAFE will provide one tool that shows alerts in the data blocks and compression errors via cones on the final approach, implementing all tactical conflict detection and alerting via one tool in TRACON airspace.
Austrian, Jonathan S; Jamin, Catherine T; Doty, Glenn R; Blecker, Saul
2018-05-01
The purpose of this study was to determine whether an electronic health record-based sepsis alert system could improve quality of care and clinical outcomes for patients with sepsis. We performed a patient-level interrupted time series study of emergency department patients with severe sepsis or septic shock between January 2013 and April 2015. The intervention, introduced in February 2014, was a system of interruptive sepsis alerts triggered by abnormal vital signs or laboratory results. Primary outcomes were length of stay (LOS) and in-hospital mortality; other outcomes included time to first lactate and blood cultures prior to antibiotics. We also assessed sensitivity, positive predictive value (PPV), and clinician response to the alerts. Mean LOS for patients with sepsis decreased from 10.1 to 8.6 days (P < .001) following alert introduction. In adjusted time series analysis, the intervention was associated with a decreased LOS of 16% (95% CI, 5%-25%; P = .007, with significance of α = 0.006) and no change thereafter (0%; 95% CI, -2%, 2%). The sepsis alert system had no effect on mortality or other clinical or process measures. The intervention had a sensitivity of 80.4% and a PPV of 14.6%. Alerting based on simple laboratory and vital sign criteria was insufficient to improve sepsis outcomes. Alert fatigue due to the low PPV is likely the primary contributor to these results. A more sophisticated algorithm for sepsis identification is needed to improve outcomes.
Kyi, M; Wraight, P R; Rowan, L M; Marley, K A; Colman, P G; Fourlanos, S
2018-06-01
To investigate the effect of a novel glucose alert system, comprising the Melbourne Glucose Alert Pathway and glucose-alert-capable networked blood glucose meters, on nursing and hospital medical officer responses to adverse glycaemia. A prospective, pre- and post-observational study was undertaken in non-critical care wards of a tertiary hospital over 4 months (n=148 or 660 patient-days). The intervention consisted of two components designed to promote a consistent staff response to blood glucose measurements: (1) a clinical escalation pathway, the Melbourne Glucose Alert Pathway, and (2) networked blood glucose meters, which provide a visual alert for out-of-range blood glucose measurement. All consecutive inpatients with diabetes were assessed for diabetes management and capillary blood glucose. The primary outcome was documented nursing and medical staff action in response to episodes of adverse glycaemia (blood glucose >15 mmol/l or <4 mmol/l). Secondary outcomes consisted of glycaemic measures. In response to episodes of adverse glycaemia, nursing action increased (proportion with nursing action: 45% to 73%; P<0.001), and medical action increased (proportion with medical action: 49% to 67%; P=0.011) with the glucose alert system in place. Patient-days with hyperglycaemia (any blood glucose value >15 mmol/l: 24% vs 16%; P=0.012) and patient-days with mean blood glucose >15 mmol/l (7.4% vs 2.6%; P=0.005) decreased. There was no difference in hypoglycaemia incidence. Use of a novel glucose alert system improved health professional responses to adverse glycaemia and decreased hyperglycaemia in the hospital setting. © 2018 Diabetes UK.
47 CFR 10.440 - Embedded reference prohibition.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 47 Telecommunication 1 2010-10-01 2010-10-01 false Embedded reference prohibition. 10.440 Section 10.440 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM Alert Message Requirements § 10.440 Embedded reference prohibition. A CMAS Alert Message processed by a...
47 CFR 10.320 - Provider alert gateway requirements.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 47 Telecommunication 1 2010-10-01 2010-10-01 false Provider alert gateway requirements. 10.320 Section 10.320 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM... that each Participating Commercial Mobile Service provider is required to support and perform at its...
47 CFR 10.420 - Message elements.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 47 Telecommunication 1 2010-10-01 2010-10-01 false Message elements. 10.420 Section 10.420 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM Alert Message Requirements § 10.420 Message elements. A CMAS Alert Message processed by a Participating CMS Provider shall...
Code of Federal Regulations, 2012 CFR
2012-10-01
... 47 Telecommunication 1 2012-10-01 2012-10-01 false Definitions. 10.10 Section 10.10 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM General Information § 10.10 Definitions. (a) Alert Message. An Alert Message is a message that is intended to provide the...
47 CFR 10.440 - Embedded reference prohibition.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 47 Telecommunication 1 2012-10-01 2012-10-01 false Embedded reference prohibition. 10.440 Section 10.440 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM Alert Message Requirements § 10.440 Embedded reference prohibition. A CMAS Alert Message processed by a...
47 CFR 10.440 - Embedded reference prohibition.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 47 Telecommunication 1 2011-10-01 2011-10-01 false Embedded reference prohibition. 10.440 Section 10.440 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM Alert Message Requirements § 10.440 Embedded reference prohibition. A CMAS Alert Message processed by a...
Impact-based earthquake alerts with the U.S. Geological Survey's PAGER system: what's next?
Wald, D.J.; Jaiswal, K.S.; Marano, K.D.; Garcia, D.; So, E.; Hearne, M.
2012-01-01
In September 2010, the USGS began publicly releasing earthquake alerts for significant earthquakes around the globe based on estimates of potential casualties and economic losses with its Prompt Assessment of Global Earthquakes for Response (PAGER) system. These estimates significantly enhanced the utility of the USGS PAGER system which had been, since 2006, providing estimated population exposures to specific shaking intensities. Quantifying earthquake impacts and communicating estimated losses (and their uncertainties) to the public, the media, humanitarian, and response communities required a new protocol—necessitating the development of an Earthquake Impact Scale—described herein and now deployed with the PAGER system. After two years of PAGER-based impact alerting, we now review operations, hazard calculations, loss models, alerting protocols, and our success rate for recent (2010-2011) events. This review prompts analyses of the strengths, limitations, opportunities, and pressures, allowing clearer definition of future research and development priorities for the PAGER system.
Teklehaimanot, Hailay D; Schwartz, Joel; Teklehaimanot, Awash; Lipsitch, Marc
2004-11-19
Timely and accurate information about the onset of malaria epidemics is essential for effective control activities in epidemic-prone regions. Early warning methods that provide earlier alerts (usually by the use of weather variables) may permit control measures to interrupt transmission earlier in the epidemic, perhaps at the expense of some level of accuracy. Expected case numbers were modeled using a Poisson regression with lagged weather factors in a 4th-degree polynomial distributed lag model. For each week, the numbers of malaria cases were predicted using coefficients obtained using all years except that for which the prediction was being made. The effectiveness of alerts generated by the prediction system was compared against that of alerts based on observed cases. The usefulness of the prediction system was evaluated in cold and hot districts. The system predicts the overall pattern of cases well, yet underestimates the height of the largest peaks. Relative to alerts triggered by observed cases, the alerts triggered by the predicted number of cases performed slightly worse, within 5% of the detection system. The prediction-based alerts were able to prevent 10-25% more cases at a given sensitivity in cold districts than in hot ones. The prediction of malaria cases using lagged weather performed well in identifying periods of increased malaria cases. Weather-derived predictions identified epidemics with reasonable accuracy and better timeliness than early detection systems; therefore, the prediction of malarial epidemics using weather is a plausible alternative to early detection systems.
Status and expected perfomance of the MAXI mission for the JEM/ISS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kataoka, J.; Kawai, N.
2008-12-24
MAXI (Monitor of All-sky X-ray Image) is the first payload to be attached on JEM-EF (Kibo exposed facility) of ISS. It provides an all sky X-ray image every ISS orbit. Only with a few weeks scan, MAXI is expected to make a milli-Crab X-ray all sky map excluding bright region around the sun. Thus, MAXI does not only inform X-ray novae and transients rapidly to world astronomers if once they occur, but also observes long-term variability of Galact ic and extra-Galactic X-ray sources. MAXI also provides an X-ray source catalogue at that time with diffuse cosmic X-ray background. MAXI consistsmore » of two kinds of detectors, position sensitive gas-proportional counters for 2-30 keV X-rays and CCD cameras for 0.5-10 keV X-rays. All instruments of MAXI are now in final phase of pre-launching tests of their flight modules. We are also carrying out performance tests for X-ray detectors and collimators. Data processing and analysis software including alert system on ground are being developed by mission team. In this paper we report an overview of final instruments of MAXI and capability of MAXI.« less
Coordinated Displays to Assist Cyber Defenders
2016-09-23
suspicious activity, such as the occurrence of a network event that is similar to a known attack signature, the system generates an alert which is then...presented to a human computer network defense analyst, or more succinctly, a network analyst, who must evaluate the veracity of that alert . To...display and select an alert to investigate further. Though alerts generally include some information about the nature of a potential threat, the
The Zwicky Transient Facility Public Alert Stream
NASA Astrophysics Data System (ADS)
Masci, F.; Kulkarni, S. R.; Graham, M.; Prince, T.; Helou, G.
2018-06-01
The Zwicky Transient Facility (ZTF; ATel #11266) announces the start of public alerts. These alerts will originate from the ZTF public surveys (Bellm & Kulkarni 2017; Nature Astronomy 1, 71) as described at www.ztf.caltech.edu/page/msip Alerts are generated by the ZTF Science Data System housed at IPAC-Caltech (www.ipac.caltech.edu) using a realtime image-subtraction pipeline (Masci et al. 2018; www.ztf.caltech.edu/page/technical).
MyEEW: A Smartphone App for the ShakeAlert System
NASA Astrophysics Data System (ADS)
Strauss, J. A.; Allen, S.; Allen, R. M.; Hellweg, M.
2015-12-01
Earthquake Early Warning (EEW) is a system that can provide a few to tens of seconds warning prior to ground shaking at a user's location. The goal and purpose of such a system is to reduce, or minimize, the damage, costs, and casualties resulting from an earthquake. A demonstration earthquake early warning system (ShakeAlert) is undergoing testing in the United States by the UC Berkeley Seismological Laboratory, Caltech, ETH Zurich, University of Washington, the USGS, and beta users in California and the Pacific Northwest. The UC Berkeley Seismological Laboratory has created a smartphone app called MyEEW, which interfaces with the ShakeAlert system to deliver early warnings to individual users. Many critical facilities (transportation, police, and fire) have control rooms, which could run a centralized interface, but our ShakeAlert Beta Testers have also expressed their need for mobile options. This app augments the basic ShakeAlert Java desktop applet by allowing workers off-site (or merely out of hearing range) to be informed of coming hazards. MyEEW receives information from the ShakeAlert system to provide users with real-time information about shaking that is about to happen at their individual location. It includes a map, timer, and earthquake information similar to the Java desktop User Display. The app will also feature educational material to help users craft their own response and resiliency strategies. The app will be open to UC Berkeley Earthquake Research Affiliates members for testing in the near future.
47 CFR 10.430 - Character limit.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 47 Telecommunication 1 2010-10-01 2010-10-01 false Character limit. 10.430 Section 10.430 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM Alert Message Requirements § 10.430 Character limit. A CMAS Alert Message processed by a Participating CMS Provider must not...
Alerts Analysis and Visualization in Network-based Intrusion Detection Systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yang, Dr. Li
2010-08-01
The alerts produced by network-based intrusion detection systems, e.g. Snort, can be difficult for network administrators to efficiently review and respond to due to the enormous number of alerts generated in a short time frame. This work describes how the visualization of raw IDS alert data assists network administrators in understanding the current state of a network and quickens the process of reviewing and responding to intrusion attempts. The project presented in this work consists of three primary components. The first component provides a visual mapping of the network topology that allows the end-user to easily browse clustered alerts. Themore » second component is based on the flocking behavior of birds such that birds tend to follow other birds with similar behaviors. This component allows the end-user to see the clustering process and provides an efficient means for reviewing alert data. The third component discovers and visualizes patterns of multistage attacks by profiling the attacker s behaviors.« less
ERIC Educational Resources Information Center
Dringus, Laurie P.; Scigliano, John A.
2000-01-01
Traces the major historical milestones achieved by Nova Southeastern University in its pioneering of graduate level online learning programs. Highlights include delivery systems; Web-based electronic classrooms; overview of the technology, including telecommunications through UNIX; evaluation and research; and technology used in the School of…
The national web-based outbreak rapid alert system in Norway: eight years of experience, 2006-2013.
Guzman-Herrador, B; Vold, L; Berg, T; Berglund, T M; Heier, B; Kapperud, G; Lange, H; Nygård, K
2016-01-01
In 2005, the Norwegian Institute of Public Health established a web-based outbreak rapid alert system called Vesuv. The system is used for mandatory outbreak alerts from municipal medical officers, healthcare institutions, and food safety authorities. As of 2013, 1426 outbreaks have been reported, involving 32913 cases. More than half of the outbreaks occurred in healthcare institutions (759 outbreaks, 53·2%). A total of 474 (33·2%) outbreaks were associated with food or drinking water. The web-based rapid alert system has proved to be a helpful tool by enhancing reporting and enabling rapid and efficient information sharing between different authorities at both the local and national levels. It is also an important tool for event-based reporting, as required by the International Health Regulations (IHR) 2005. Collecting information from all the outbreak alerts and reports in a national database is also useful for analysing trends, such as occurrence of certain microorganisms, places or sources of infection, or route of transmission. This can facilitate the identification of specific areas where more general preventive measures are needed.
Personalized and automated remote monitoring of atrial fibrillation.
Rosier, Arnaud; Mabo, Philippe; Temal, Lynda; Van Hille, Pascal; Dameron, Olivier; Deléger, Louise; Grouin, Cyril; Zweigenbaum, Pierre; Jacques, Julie; Chazard, Emmanuel; Laporte, Laure; Henry, Christine; Burgun, Anita
2016-03-01
Remote monitoring of cardiac implantable electronic devices is a growing standard; yet, remote follow-up and management of alerts represents a time-consuming task for physicians or trained staff. This study evaluates an automatic mechanism based on artificial intelligence tools to filter atrial fibrillation (AF) alerts based on their medical significance. We evaluated this method on alerts for AF episodes that occurred in 60 pacemaker recipients. AKENATON prototype workflow includes two steps: natural language-processing algorithms abstract the patient health record to a digital version, then a knowledge-based algorithm based on an applied formal ontology allows to calculate the CHA2DS2-VASc score and evaluate the anticoagulation status of the patient. Each alert is then automatically classified by importance from low to critical, by mimicking medical reasoning. Final classification was compared with human expert analysis by two physicians. A total of 1783 alerts about AF episode >5 min in 60 patients were processed. A 1749 of 1783 alerts (98%) were adequately classified and there were no underestimation of alert importance in the remaining 34 misclassified alerts. This work demonstrates the ability of a pilot system to classify alerts and improves personalized remote monitoring of patients. In particular, our method allows integration of patient medical history with device alert notifications, which is useful both from medical and resource-management perspectives. The system was able to automatically classify the importance of 1783 AF alerts in 60 patients, which resulted in an 84% reduction in notification workload, while preserving patient safety. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2015. For permissions please email: journals.permissions@oup.com.
Krall, M. A.; Sittig, D. F.
2001-01-01
There is very little known about the limits of alerting in the setting of the outpatient Electronic Medical Record (EMR). We are interested in how users value and prefer such alerts. One hundred Kaiser Permanente primary care clinicians were sent a four-page questionnaire. It contained questions related to the usability and usefulness of different approaches to presenting reminder and alert information. The survey also contained questions about the desirability of six categories of alerts. Forty-three of 100 questionnaires were returned. Users generally preferred an active, more intrusive interaction model for "alerts" and a passive, less intrusive model for order messages and other types of reminders and notifications. Drug related alerts were more highly rated than health maintenance or disease state reminders. Users indicated that more alerts would make the system "more useful" but "less easy to use". PMID:11825206
Krall, M A; Sittig, D F
2001-01-01
There is very little known about the limits of alerting in the setting of the outpatient Electronic Medical Record (EMR). We are interested in how users value and prefer such alerts. One hundred Kaiser Permanente primary care clinicians were sent a four-page questionnaire. It contained questions related to the usability and usefulness of different approaches to presenting reminder and alert information. The survey also contained questions about the desirability of six categories of alerts. Forty-three of 100 questionnaires were returned. Users generally preferred an active, more intrusive interaction model for "alerts" and a passive, less intrusive model for order messages and other types of reminders and notifications. Drug related alerts were more highly rated than health maintenance or disease state reminders. Users indicated that more alerts would make the system "more useful" but "less easy to use".
ElarmS Earthquake Early Warning System: 2017 Performance and New ElarmS Version 3.0 (E3)
NASA Astrophysics Data System (ADS)
Chung, A. I.; Henson, I. H.; Allen, R. M.; Hellweg, M.; Neuhauser, D. S.
2017-12-01
The ElarmS earthquake early warning (EEW) system has been successfully detecting earthquakes throughout California since 2007. ElarmS version 2.0 (E2) is one of the three algorithms contributing alerts to ShakeAlert, a public EEW system being developed by the USGS in collaboration with UC Berkeley, Caltech, University of Washington, and University of Oregon. E2 began operating in test mode in the Pacific Northwest in 2013, and since April of this year E2 has been contributing real-time alerts from Oregon and Washington to the ShakeAlert production prototype system as part of the ShakeAlert roll-out throughout the West Coast. Since it began operating west-coast-wide, E2 has correctly alerted on 5 events that matched ANSS catalog events with M≥4, missed 1 event with M≥4, and incorrectly created alerts for 5 false events with M≥4. The most recent version of the algorithm, ElarmS version 3.0 (E3), is a significant improvement over E2. It addresses some of the most problematic causes of false events for which E2 produced alerts, without impacting reliability in terms of matched and missed events. Of the 5 false events that were generated by E2 since April, 4 would have been suppressed by E3. In E3, we have added a filterbank teleseismic filter. By analyzing the amplitude of the waveform filtered in various passbands, it is possible to distinguish between local and teleseismic events. We have also added a series of checks to validate triggers and filter out spurious and S-wave triggers. Additional improvements to the waveform associator also improve detections. In this presentation, we describe the improvements and compare the performance of the current production (E2) and development (E3) versions of ElarmS over the past year. The ShakeAlert project is now working through a streamlining process to identify the best components of various algorithms and merge them. The ElarmS team is participating in this effort and we anticipate that much of E3 will continue in the final system.
Colpitts, Emily; Gahagan, Jacqueline
2016-09-22
Currently, there is a dearth of baseline data on the health of lesbian, gay, bisexual, transgender, and queer (LGBTQ) populations in the province of Nova Scotia, Canada. Historically, LGBTQ health research has tended to focus on individual-level health risks associated with poor health outcomes among these populations, which has served to obscure the ways in which they maintain their own health and wellness across the life course. As such, there is an urgent need to shift the focus of LGBTQ health research towards strengths-based perspectives that explore the complex and resilient ways in which LGBTQ populations promote their health. This paper discusses the findings of our recent scoping review as well as the qualitative data to emerge from community consultations aimed at developing strengths-based approaches to understanding and advancing LGBTQ pathways to health across Nova Scotia. Our scoping review findings demonstrated the lack of strengths-based research on LGBTQ health in Nova Scotia. Specifically, the studies examined in our scoping review identified a number of health-promoting factors and a wide variety of measurement tools, some of which may prove useful for future strengths-based health research with LGBTQ populations. In addition, our community consultations revealed that many participants had negative experiences with health care systems and services in Nova Scotia. However, participants also shared a number of factors that contribute to LGBTQ health and suggestions for how LGBTQ pathways to health in Nova Scotia can be improved. There is an urgent need to conduct research on the health needs, lived experiences, and outcomes of LGBTQ populations in Nova Scotia to address gaps in our knowledge of their unique health needs. In moving forward, it is important that future health research take an intersectional, strengths-based perspective in an effort to highlight the factors that promote LGBTQ health and wellness across the life course, while taking into account the social determinants of health.
Evaluation of health alerts from an early illness warning system in independent living.
Rantz, Marilyn J; Scott, Susan D; Miller, Steven J; Skubic, Marjorie; Phillips, Lorraine; Alexander, Greg; Koopman, Richelle J; Musterman, Katy; Back, Jessica
2013-06-01
Passive sensor networks were deployed in independent living apartments to monitor older adults in their home environments to detect signs of impending illness and alert clinicians so they can intervene and prevent or delay significant changes in health or functional status. A retrospective qualitative deductive content analysis was undertaken to refine health alerts to improve clinical relevance to clinicians as they use alerts in their normal workflow of routine care delivery to older adults. Clinicians completed written free-text boxes to describe actions taken (or not) as a result of each alert; they also rated the clinical significance (relevance) of each health alert on a scale of 1 to 5. Two samples of the clinician's written responses to the health alerts were analyzed after alert algorithms had been adjusted based on results of a pilot study using health alerts to enhance clinical decision-making. In the first sample, a total of 663 comments were generated by seven clinicians in response to 385 unique alerts; there are more comments than alerts because more than one clinician rated the same alert. The second sample had a total of 142 comments produced by three clinicians in response to 88 distinct alerts. The overall clinical relevance of the alerts, as judged by the content of the qualitative comments by clinicians for each alert, improved from 33.3% of the alerts in the first sample classified as clinically relevant to 43.2% in the second. The goal is to produce clinically relevant alerts that clinicians find useful in daily practice. The evaluation methods used are described to assist others as they consider building and iteratively refining health alerts to enhance clinical decision making.
Perceptual evaluation of visual alerts in surveillance videos
NASA Astrophysics Data System (ADS)
Rogowitz, Bernice E.; Topkara, Mercan; Pfeiffer, William; Hampapur, Arun
2015-03-01
Visual alerts are commonly used in video monitoring and surveillance systems to mark events, presumably making them more salient to human observers. Surprisingly, the effectiveness of computer-generated alerts in improving human performance has not been widely studied. To address this gap, we have developed a tool for simulating different alert parameters in a realistic visual monitoring situation, and have measured human detection performance under conditions that emulated different set-points in a surveillance algorithm. In the High-Sensitivity condition, the simulated alerts identified 100% of the events with many false alarms. In the Lower-Sensitivity condition, the simulated alerts correctly identified 70% of the targets, with fewer false alarms. In the control condition, no simulated alerts were provided. To explore the effects of learning, subjects performed these tasks in three sessions, on separate days, in a counterbalanced, within subject design. We explore these results within the context of cognitive models of human attention and learning. We found that human observers were more likely to respond to events when marked by a visual alert. Learning played a major role in the two alert conditions. In the first session, observers generated almost twice as many False Alarms as in the No-Alert condition, as the observers responded pre-attentively to the computer-generated false alarms. However, this rate dropped equally dramatically in later sessions, as observers learned to discount the false cues. Highest observer Precision, Hits/(Hits + False Alarms), was achieved in the High Sensitivity condition, but only after training. The successful evaluation of surveillance systems depends on understanding human attention and performance.
NASA Technical Reports Server (NTRS)
Simpson, Robert W.
1991-01-01
Brief summaries are given of research activities at the Massachusetts Institute of Technology (MIT) under the sponsorship of the FAA/NASA Joint University Program. Topics covered include hazard assessment and cockpit presentation issues for microburst alerting systems; the situational awareness effect of automated air traffic control (ATC) datalink clearance amendments; a graphical simulation system for adaptive, automated approach spacing; an expert system for temporal planning with application to runway configuration management; deterministic multi-zone ice accretion modeling; alert generation and cockpit presentation for an integrated microburst alerting system; and passive infrared ice detection for helicopter applications.
14 CFR 135.150 - Public address and crewmember interphone systems.
Code of Federal Regulations, 2014 CFR
2014-01-01
... to alert flight crewmembers; (iii) For the alerting system required by paragraph (b)(7)(ii) of this... systems. 135.150 Section 135.150 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF... Aircraft and Equipment § 135.150 Public address and crewmember interphone systems. No person may operate an...
14 CFR 135.150 - Public address and crewmember interphone systems.
Code of Federal Regulations, 2013 CFR
2013-01-01
... to alert flight crewmembers; (iii) For the alerting system required by paragraph (b)(7)(ii) of this... systems. 135.150 Section 135.150 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF... Aircraft and Equipment § 135.150 Public address and crewmember interphone systems. No person may operate an...
14 CFR 135.150 - Public address and crewmember interphone systems.
Code of Federal Regulations, 2012 CFR
2012-01-01
... to alert flight crewmembers; (iii) For the alerting system required by paragraph (b)(7)(ii) of this... systems. 135.150 Section 135.150 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF... Aircraft and Equipment § 135.150 Public address and crewmember interphone systems. No person may operate an...
Developing, Implementing, and Assessing an Early Alert System
ERIC Educational Resources Information Center
Tampke, Dale R.
2013-01-01
Early alert systems offer institutions systematic approaches to identifying and intervening with students exhibiting at-risk behaviors. Many of these systems rely on a common format for student referral to central receiving point. Systems at larger institutions often use web-based technology to allow for a scalable (available campus wide) approach…
14 CFR 135.150 - Public address and crewmember interphone systems.
Code of Federal Regulations, 2010 CFR
2010-01-01
... to alert flight crewmembers; (iii) For the alerting system required by paragraph (b)(7)(ii) of this... systems. 135.150 Section 135.150 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF... Aircraft and Equipment § 135.150 Public address and crewmember interphone systems. No person may operate an...
14 CFR 135.150 - Public address and crewmember interphone systems.
Code of Federal Regulations, 2011 CFR
2011-01-01
... to alert flight crewmembers; (iii) For the alerting system required by paragraph (b)(7)(ii) of this... systems. 135.150 Section 135.150 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF... Aircraft and Equipment § 135.150 Public address and crewmember interphone systems. No person may operate an...
Work zone intrusion alert technologies : assessment and practical guidance : final report.
DOT National Transportation Integrated Search
2017-06-01
A work zone intrusion alert technology is a type of safety system that is used in a roadway work zone to alert field workers and secure time for them to escape when errant vehicles intrude into the work zone. Although such technologies have potential...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-03-03
... Committee 147: Minimum Operational Performance Standards for Traffic Alert and Collision Avoidance Systems... Committee 147 meeting: Minimum Operational Performance Standards for Traffic Alert and Collision Avoidance... RTCA Special Committee 147: Minimum Operational Performance Standards for Traffic Alert and Collision...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-09-19
... Committee 147: Minimum Operational Performance Standards for Traffic Alert and Collision Avoidance Systems... Committee 147 meeting: Minimum Operational Performance Standards for Traffic Alert and Collision Avoidance... RTCA Special Committee 147: Minimum Operational Performance Standards for Traffic Alert and Collision...
Delivering Alert Messages to Members of a Work Force
NASA Technical Reports Server (NTRS)
Loftis, Julia; Nickens, Stephanie; Pell, Melissa; Pell, Vince
2008-01-01
Global Alert Resolution Network (GARNET) is a software system for delivering emergency alerts as well as less-urgent messages to members of the Goddard Space Flight Center work force via an intranet or the Internet, and can be adapted to similar use in other large organizations.
Solar radiation alert system : final report.
DOT National Transportation Integrated Search
2009-03-01
The Solar Radiation Alert (SRA) system continuously evaluates measurements of high-energy protons made by instruments on GOES satellites. If the measurements indicate a substantial elevation of effective dose rates at aircraft flight altitudes, the C...
NASA Technical Reports Server (NTRS)
Sandor, A.; Moses, H. R.
2016-01-01
Currently on the International Space Station (ISS) and other space vehicles Caution & Warning (C&W) alerts are represented with various auditory tones that correspond to the type of event. This system relies on the crew's ability to remember what each tone represents in a high stress, high workload environment when responding to the alert. Furthermore, crew receive a year or more in advance of the mission that makes remembering the semantic meaning of the alerts more difficult. The current system works for missions conducted close to Earth where ground operators can assist as needed. On long duration missions, however, they will need to work off-nominal events autonomously. There is evidence that speech alarms may be easier and faster to recognize, especially during an off-nominal event. The Information Presentation Directed Research Project (FY07-FY09) funded by the Human Research Program included several studies investigating C&W alerts. The studies evaluated tone alerts currently in use with NASA flight deck displays along with candidate speech alerts. A follow-on study used four types of speech alerts to investigate how quickly various types of auditory alerts with and without a speech component - either at the beginning or at the end of the tone - can be identified. Even though crew were familiar with the tone alert from training or direct mission experience, alerts starting with a speech component were identified faster than alerts starting with a tone. The current study replicated the results from the previous study in a more rigorous experimental design to determine if the candidate speech alarms are ready for transition to operations or if more research is needed. Four types of alarms (caution, warning, fire, and depressurization) were presented to participants in both tone and speech formats in laboratory settings and later in the Human Exploration Research Analog (HERA). In the laboratory study, the alerts were presented by software and participants were asked to identify the alert as quickly and as accurately as possible. Reaction time and accuracy were measured. Participants identified speech alerts significantly faster than tone alerts. The HERA study investigated the performance of participants in a flight-like environment. Participants were instructed to complete items on a task list and respond to C&W alerts as they occurred. Reaction time and accuracy were measured to determine if the benefits of speech alarms are still present in an applied setting.
Lee, Christopher T; Bulterys, Marc; Martel, Lise D; Dahl, Benjamin A
2016-03-11
The epidemic of Ebola virus disease (Ebola) in West Africa began in Guinea in late 2013 (1), and on August 8, 2014, the World Health Organization (WHO) declared the epidemic a Public Health Emergency of International Concern (2). Guinea was declared Ebola-free on December 29, 2015, and is under a 90 day period of enhanced surveillance, following 3,351 confirmed and 453 probable cases of Ebola and 2,536 deaths (3). Passive surveillance for Ebola in Guinea has been conducted principally through the use of a telephone alert system. Community members and health facilities report deaths and suspected Ebola cases to local alert numbers operated by prefecture health departments or to a national toll-free call center. The national call center additionally functions as a source of public health information by responding to questions from the public about Ebola. To evaluate the sensitivity of the two systems and compare the sensitivity of the national call center with the local alerts system, the CDC country team performed probabilistic record linkage of the combined prefecture alerts database, as well as the national call center database, with the national viral hemorrhagic fever (VHF) database; the VHF database contains records of all known confirmed Ebola cases. Among 17,309 alert calls analyzed from the national call center, 71 were linked to 1,838 confirmed Ebola cases in the VHF database, yielding a sensitivity of 3.9%. The sensitivity of the national call center was highest in the capital city of Conakry (11.4%) and lower in other prefectures. In comparison, the local alerts system had a sensitivity of 51.1%. Local public health infrastructure plays an important role in surveillance in an epidemic setting.
Benefit Value to the Air Force of the GIDEP (Government Industry Data Exchange Program) Alert
1984-06-15
cost avoidance within that organization is not the result of the ALERT system . 3-1 b) Designed Life - This is the expected life of the item as...Analytics1 Phase II efforts under contract F33615-S3- C-5098. The main findings of the report are: (1) The system set up to handle Government...slow to issue ALERTs. (4) There is no formally documented system for determining that the Air Force’s warranty rights are being enforced on items
Pi-EEWS: a low cost prototype for on-site earthquake early warning system
NASA Astrophysics Data System (ADS)
Pazos, Antonio; Vera, Angel; Morgado, Arturo; Rioja, Carlos; Davila, Jose Martin; Cabieces, Roberto
2017-04-01
The Royal Spanish Navy Observatory (ROA), with the participation of the Cadiz University (UCA), have been developed the ALERTES-SC3 EEWS (regional approach) based on the SeisComP3 software package. This development has been done in the frame of the Spanish ALERT-ES (2011-2013) and ALERTES-RIM (2014-2016) projects, and now a days it is being tested in real time for south Iberia. Additionally, the ALERTES-SC3 system integrates an on-site EEWS software, developed by ROA-UCA, which is running for testing in real time in some seismic broad band stations of the WM network. Regional EEWS are not able to provide alerts in the area closet to the epicentre (blind zone), so a dense on-site EEWS is necessary. As it was mentioned, ALERTES-SC3 inludes the on-site software running on several WM stations but a more dense on-site stations are necessary to cover the blind zones. In order to densify this areas, inside of the "blind zones", a low cost on-site prototype "Pi-EEWS", based on a Raspberry Pi card and low cost acelerometers. In this work the main design ideas, the components and its capabilities will be shown.
TMS communications hardware. Volume 1: Computer interfaces
NASA Technical Reports Server (NTRS)
Brown, J. S.; Weinrich, S. S.
1979-01-01
A prototpye coaxial cable bus communications system was designed to be used in the Trend Monitoring System (TMS) to connect intelligent graphics terminals (based around a Data General NOVA/3 computer) to a MODCOMP IV host minicomputer. The direct memory access (DMA) interfaces which were utilized for each of these computers are identified. It is shown that for the MODCOMP, an off-the-shell board was suitable, while for the NOVAs, custon interface circuitry was designed and implemented.
NOVA2-mediated RNA regulation is required for axonal pathfinding during development.
Saito, Yuhki; Miranda-Rottmann, Soledad; Ruggiu, Matteo; Park, Christopher Y; Fak, John J; Zhong, Ru; Duncan, Jeremy S; Fabella, Brian A; Junge, Harald J; Chen, Zhe; Araya, Roberto; Fritzsch, Bernd; Hudspeth, A J; Darnell, Robert B
2016-05-25
The neuron specific RNA-binding proteins NOVA1 and NOVA2 are highly homologous alternative splicing regulators. NOVA proteins regulate at least 700 alternative splicing events in vivo, yet relatively little is known about the biologic consequences of NOVA action and in particular about functional differences between NOVA1 and NOVA2. Transcriptome-wide searches for isoform-specific functions, using NOVA1 and NOVA2 specific HITS-CLIP and RNA-seq data from mouse cortex lacking either NOVA isoform, reveals that NOVA2 uniquely regulates alternative splicing events of a series of axon guidance related genes during cortical development. Corresponding axonal pathfinding defects were specific to NOVA2 deficiency: Nova2-/- but not Nova1-/- mice had agenesis of the corpus callosum, and axonal outgrowth defects specific to ventral motoneuron axons and efferent innervation of the cochlea. Thus we have discovered that NOVA2 uniquely regulates alternative splicing of a coordinate set of transcripts encoding key components in cortical, brainstem and spinal axon guidance/outgrowth pathways during neural differentiation, with severe functional consequences in vivo.
Safety Alerts: An Observational Study in Portugal.
Soares, Sara; Roque, Fátima; Teixeira Rodrigues, António; Figueiras, Adolfo; Herdeiro, Maria Teresa
2015-09-01
The information that is available when marketing authorizations are approved is limited. Pharmacovigilance has an important role during the postauthorization period, and alerts published by national authorities allow health care professionals to be informed about new data on safety profiles. This study therefore sought to analyze all safety alerts published by the Portuguese National Authority of Medicines and Health Products I.P. (INFARMED). We conducted an observational study of all alerts published on the INFARMED website from January 2002 through December 2014. From the data included in the alerts, the following information was abstracted: active substance name (and trade name), event that led to the alert, and the resulting safety measures. Active substances were classified according to the Anatomical Therapeutic Chemical (ATC) code. A total of 562 alerts were published, and 304 were eligible for inclusion. The musculoskeletal system was the ATC code with more alerts (n = 53), followed by the nervous system (n = 42). Communication of the information and recommendations to the health care professionals and the public in general was the most frequent safety measure (n = 128), followed by changes in the Summary of the Product Characteristics and package information leaflet (n = 66). During the study period, 26 marketing authorizations were temporarily suspended and 10 were revoked. The knowledge of the alerts published during the postmarketing period is very useful to the health care professionals for improving prescription and use of medicines and to the scientific community for the development of new researches. Copyright © 2015 Elsevier HS Journals, Inc. All rights reserved.
Improving the Quality of Alerts and Predicting Intruder's Next Goal with Hidden Colored Petri-Net
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yu, Dong; Frincke, Deb A.
2006-06-22
Intrusion detection systems (IDS) often provide poor quality alerts, which are insufficient to support rapid identification of ongoing attacks or predict an intruder’s next likely goal. In this paper, we propose a novel approach to alert post-processing and correlation, the Hidden Colored Petri-Net (HCPN). Different from most other alert correlation methods, our approach treats the alert correlation problem as an inference problem rather than a filter problem. Our approach assumes that the intruder’s actions are unknown to the IDS and can be inferred only from the alerts generated by the IDS sensors. HCPN can describe the relationship between different stepsmore » carried out by intruders, model observations (alerts) and transitions (actions) separately, and associate each token element (system state) with a probability (or confidence). The model is an extension to Colored Petri-Net (CPN) .It is so called “hidden” because the transitions (actions) are not directly observable but can be inferred by looking through the observations (alerts). These features make HCPN especially suitable for discovering intruders’ actions from their partial observations (alerts,) and predicting intruders’ next goal. Our experiments on DARPA evaluation datasets and the attack scenarios from the Grand Challenge Problem (GCP) show that HCPN has promise as a way to reducing false positives and negatives, predicting intruder’s next possible action, uncovering intruders’ intrusion strategies after the attack scenario has happened, and providing confidence scores.« less
The effect of phasic auditory alerting on visual perception.
Petersen, Anders; Petersen, Annemarie Hilkjær; Bundesen, Claus; Vangkilde, Signe; Habekost, Thomas
2017-08-01
Phasic alertness refers to a short-lived change in the preparatory state of the cognitive system following an alerting signal. In the present study, we examined the effect of phasic auditory alerting on distinct perceptual processes, unconfounded by motor components. We combined an alerting/no-alerting design with a pure accuracy-based single-letter recognition task. Computational modeling based on Bundesen's Theory of Visual Attention was used to examine the effect of phasic alertness on visual processing speed and threshold of conscious perception. Results show that phasic auditory alertness affects visual perception by increasing the visual processing speed and lowering the threshold of conscious perception (Experiment 1). By manipulating the intensity of the alerting cue, we further observed a positive relationship between alerting intensity and processing speed, which was not seen for the threshold of conscious perception (Experiment 2). This was replicated in a third experiment, in which pupil size was measured as a physiological marker of alertness. Results revealed that the increase in processing speed was accompanied by an increase in pupil size, substantiating the link between alertness and processing speed (Experiment 3). The implications of these results are discussed in relation to a newly developed mathematical model of the relationship between levels of alertness and the speed with which humans process visual information. Copyright © 2017 Elsevier B.V. All rights reserved.
Prescription order risk factors for pediatric dosing alerts.
Stultz, J S; Porter, K; Nahata, M C
2015-02-01
To determine dosing alert rates based on prescription order characteristics and identify prescription order risk factors for the occurrence of dosing alerts. A retrospective analysis of inpatient medication orders and dosing alerts occurring during October 2011 and January, April, and July 2012 at a pediatric institution. Prescription orders and alerts were categorized by: medication class, patient age, route of administration, and month of the year. There were 228,259 orders during the studied period, with 11,072 alerted orders (4.9%). The most frequently alerted medication class was the non-analgesic central nervous system agent class (14% of alerts). Age, route, medication class, and month all independently affected dosing alert rates. The alert rate was highest for immunosuppressive agents (54%), neonates (6.7%), and orders for rectal administration (9.5%). The alert rate was higher in adult patients receiving their care at a pediatric institution (5.7%) compared to children (4.7%), but after multivariate analysis, pediatric orders had higher odds for an alert (OR 1.1, 95% CI 1.05-1.16). Mercaptopurine had the highest alert rate when categorized by active ingredient (73.9%). Albuterol 2.5mg/mL continuous aerosol and heparin 1000 units in 0.9% sodium chloride injection solution were the unique medications with the highest alert rates (100.0% and 97.7%, respectively). Certain types of prescription orders have a higher risk for causing dosing alerts than others. Patient age, medication class, route of administration, and the month of year can affect dosing alert rates. Design and customization efforts should focus on these medications and prescription order characteristics that increase the risk for dosing alerts. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Tamblyn, Robyn; Reidel, Kristen; Patel, Vaishali
2012-01-01
Objective Computerised drug alerts are expected to reduce patients’ risk of adverse drug events. However, physicians over-ride most drug alerts, because they believe that the benefit exceeds the risk. The purpose of this study was to determine the drug alert, patient and physician characteristics associated with the: (1) occurrence of psychotropic drug alerts for elderly patients and the (2) response to these alerts by their primary care physicians. Setting Primary care, Quebec, Canada. Design Prospective cohort study. Participants Sixty-one physicians using an electronic prescribing and drug alert decision-support system in their practice, and 3413 elderly patients using psychotropic drugs. Primary and secondary measures Psychotropic drug class, alert severity, patient risk for fall injuries and physician experience, practice volume and computer use were evaluated in relationship to the likelihood of having: (1) a psychotropic drug alert, (2) the prescription revised in response to an alert. Cluster-adjusted alternating logistic regression was used to assess multilevel predictors of alert occurrence and response. Results In total 13 080 psychotropic drug alerts were generated in 8931 visits. Alerts were more likely to be generated for male patients at higher risk of fall-related injury and for physicians who established the highest alert threshold. In 9.9% of alerts seen, the prescription was revised. The highest revision rate was for antipsychotic alerts (22.6%). Physicians were more likely to revise prescriptions for severe alerts (OR 2.03; 95%CI 1.39 to 2.98), if patients had cognitive impairment (OR 1.95; 95%CI 1.13 to 3.36), and if they made more visits to their physician (OR 1.05 per 5 visits; 95%CI 1 to 1.09). Conclusions Physicians view and respond to a small proportion of alerts, mainly for higher-risk patients. To reduce the risk of psychotropic drug-related fall injuries, a new generation of evidence-based drug alerts should be developed. PMID:23024254
Physician response to a medication alert system in inpatients with levodopa-treated diseases
Morris, Marie; Willis, Allison W.; Searles Nielsen, Susan; McCann, Franklin; Birke, Angela
2015-01-01
Objective: To evaluate the appropriateness of dopamine receptor antagonist prescriptions in hospitalized patients with dopamine-requiring diseases after implementation of an automated prescription alert system. Methods: We examined dopamine receptor antagonist prescriptions in hospitalized patients with dopamine-requiring diseases and physician response to an automated drug contraindication alert system at Barnes-Jewish Hospital from 2009 to 2013. A detailed review of patient medical records was performed for all alert events generated when a physician prescribed a dopamine receptor antagonist concurrently with a dopamine receptor agonist in hospitalized patients. Two movement disorders neurologists determined the appropriateness of each prescription, based on patient medical history, through consensus. Physician response to alert was compared by indication for the prescription and physician specialty. Results: Of 237 orders, 197 (83.1%) prescriptions for dopamine receptor antagonists were considered inappropriate. The prevalence of inappropriate dopamine receptor antagonist prescriptions per levodopa prescriptions was 16.10% (95% confidence interval 9.47, 22.73) in psychiatry, 7.51% (6.16, 8.86) in general medicine, 6.14% (4.49, 7.79) in the surgical specialties, and 0.85% (0.46, 1.25) in the neurologic/neurosurgical specialties. Of the inappropriate prescriptions, 146 (74.1%) were continued despite the alert. The strongest predictor of discontinuation of dopamine receptor antagonist medications was use of the medication to treat nausea or emesis (p < 0.001). Conclusions: Despite successfully identifying instances when dopamine antagonists were prescribed to patients with dopamine-requiring diseases, the alert system modestly affected physician prescribing behavior, highlighting the need for improved education of health care providers. PMID:26092916
FUSE Observations of the Bright, Eclipsing Nova-like Cataclysmic Variable, UX UMa (FUSE 2000)
NASA Technical Reports Server (NTRS)
Long, Knox; Froning, Cynthia
2004-01-01
This was a project to study the disk and wind of the eclipsing nova-like variable UX UMa, in order to better define the wind geometry of the system, including the nature of the transition region between the disk photosphere and the supersonic wind. We proposed to use phase resolved spectroscopy of the system, taking advantage of the fact that UX UMa is an eclipsing system, to isolate different regions of the wind and to use a Monte Carlo radiative transfer code to simulate the spectra through the eclipse.
ERIC Educational Resources Information Center
Wasley, Paula
2007-01-01
This article describes Hanover College's Early Alert Team, an early-alert program that seeks to identify students' academic, social, or personal troubles as soon as they surface. The team's five members gather information about students from all corners of the campus and then devise strategies to help them. The early-alert system has not only…
47 CFR 80.1113 - Transmission of a distress alert.
Code of Federal Regulations, 2014 CFR
2014-10-01
... SERVICES STATIONS IN THE MARITIME SERVICES Global Maritime Distress and Safety System (GMDSS) Operating...-shore distress alerts are used to alert Rescue Coordination Centers via coast stations or coast earth... (from a ship earth station or a satellite EPIRB) and terrestrial services (from ship stations and EPIRBs...
47 CFR 80.1113 - Transmission of a distress alert.
Code of Federal Regulations, 2012 CFR
2012-10-01
... SERVICES STATIONS IN THE MARITIME SERVICES Global Maritime Distress and Safety System (GMDSS) Operating...-shore distress alerts are used to alert Rescue Coordination Centers via coast stations or coast earth... (from a ship earth station or a satellite EPIRB) and terrestrial services (from ship stations and EPIRBs...
47 CFR 80.1113 - Transmission of a distress alert.
Code of Federal Regulations, 2013 CFR
2013-10-01
... SERVICES STATIONS IN THE MARITIME SERVICES Global Maritime Distress and Safety System (GMDSS) Operating...-shore distress alerts are used to alert Rescue Coordination Centers via coast stations or coast earth... (from a ship earth station or a satellite EPIRB) and terrestrial services (from ship stations and EPIRBs...
Downing, N. Lance; Shepard, John; Chu, Weihan; Tam, Julia; Wessels, Alexander; Li, Ron; Dietrich, Brian; Rudy, Michael; Castaneda, Leon; Shieh, Lisa
2016-01-01
Summary Bachground Increasing use of EHRs has generated interest in the potential of computerized clinical decision support to improve treatment of sepsis. Electronic sepsis alerts have had mixed results due to poor test characteristics, the inability to detect sepsis in a timely fashion and the use of outside software limiting widespread adoption. We describe the development, evaluation and validation of an accurate and timely severe sepsis alert with the potential to impact sepsis management. Objective To develop, evaluate, and validate an accurate and timely severe sepsis alert embedded in a commercial EHR. Methods The sepsis alert was developed by identifying the most common severe sepsis criteria among a cohort of patients with ICD 9 codes indicating a diagnosis of sepsis. This alert requires criteria in three categories: indicators of a systemic inflammatory response, evidence of suspected infection from physician orders, and markers of organ dysfunction. Chart review was used to evaluate test performance and the ability to detect clinical time zero, the point in time when a patient develops severe sepsis. Results Two physicians reviewed 100 positive cases and 75 negative cases. Based on this review, sensitivity was 74.5%, specificity was 86.0%, the positive predictive value was 50.3%, and the negative predictive value was 94.7%. The most common source of end-organ dysfunction was MAP less than 70 mm/Hg (59%). The alert was triggered at clinical time zero in 41% of cases and within three hours in 53.6% of cases. 96% of alerts triggered before a manual nurse screen. Conclusion We are the first to report the time between a sepsis alert and physician chart-review clinical time zero. Incorporating physician orders in the alert criteria improves specificity while maintaining sensitivity, which is important to reduce alert fatigue. By leveraging standard EHR functionality, this alert could be implemented by other healthcare systems. PMID:27437061
Rolnick, Joshua; Downing, N Lance; Shepard, John; Chu, Weihan; Tam, Julia; Wessels, Alexander; Li, Ron; Dietrich, Brian; Rudy, Michael; Castaneda, Leon; Shieh, Lisa
2016-01-01
Increasing use of EHRs has generated interest in the potential of computerized clinical decision support to improve treatment of sepsis. Electronic sepsis alerts have had mixed results due to poor test characteristics, the inability to detect sepsis in a timely fashion and the use of outside software limiting widespread adoption. We describe the development, evaluation and validation of an accurate and timely severe sepsis alert with the potential to impact sepsis management. To develop, evaluate, and validate an accurate and timely severe sepsis alert embedded in a commercial EHR. The sepsis alert was developed by identifying the most common severe sepsis criteria among a cohort of patients with ICD 9 codes indicating a diagnosis of sepsis. This alert requires criteria in three categories: indicators of a systemic inflammatory response, evidence of suspected infection from physician orders, and markers of organ dysfunction. Chart review was used to evaluate test performance and the ability to detect clinical time zero, the point in time when a patient develops severe sepsis. Two physicians reviewed 100 positive cases and 75 negative cases. Based on this review, sensitivity was 74.5%, specificity was 86.0%, the positive predictive value was 50.3%, and the negative predictive value was 94.7%. The most common source of end-organ dysfunction was MAP less than 70 mm/Hg (59%). The alert was triggered at clinical time zero in 41% of cases and within three hours in 53.6% of cases. 96% of alerts triggered before a manual nurse screen. We are the first to report the time between a sepsis alert and physician chart-review clinical time zero. Incorporating physician orders in the alert criteria improves specificity while maintaining sensitivity, which is important to reduce alert fatigue. By leveraging standard EHR functionality, this alert could be implemented by other healthcare systems.
Earthquake early Warning ShakeAlert system: West coast wide production prototype
Kohler, Monica D.; Cochran, Elizabeth S.; Given, Douglas; Guiwits, Stephen; Neuhauser, Doug; Hensen, Ivan; Hartog, Renate; Bodin, Paul; Kress, Victor; Thompson, Stephen; Felizardo, Claude; Brody, Jeff; Bhadha, Rayo; Schwarz, Stan
2017-01-01
Earthquake early warning (EEW) is an application of seismological science that can give people, as well as mechanical and electrical systems, up to tens of seconds to take protective actions before peak earthquake shaking arrives at a location. Since 2006, the U.S. Geological Survey has been working in collaboration with several partners to develop EEW for the United States. The goal is to create and operate an EEW system, called ShakeAlert, for the highest risk areas of the United States, starting with the West Coast states of California, Oregon, and Washington. In early 2016, the Production Prototype v.1.0 was established for California; then, in early 2017, v.1.2 was established for the West Coast, with earthquake notifications being distributed to a group of beta users in California, Oregon, and Washington. The new ShakeAlert Production Prototype was an outgrowth from an earlier demonstration EEW system that began sending test notifications to selected users in California in January 2012. ShakeAlert leverages the considerable physical, technical, and organizational earthquake monitoring infrastructure of the Advanced National Seismic System, a nationwide federation of cooperating seismic networks. When fully implemented, the ShakeAlert system may reduce damage and injury caused by large earthquakes, improve the nation’s resilience, and speed recovery.
Identifying and quantifying recurrent novae masquerading as classical novae
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pagnotta, Ashley; Schaefer, Bradley E., E-mail: pagnotta@amnh.org
2014-06-20
Recurrent novae (RNe) are cataclysmic variables with two or more nova eruptions within a century. Classical novae (CNe) are similar systems with only one such eruption. Many of the so-called CNe are actually RNe for which only one eruption has been discovered. Since RNe are candidate Type Ia supernova progenitors, it is important to know whether there are enough in our Galaxy to provide the supernova rate, and therefore to know how many RNe are masquerading as CNe. To quantify this, we collected all available information on the light curves and spectra of a Galactic, time-limited sample of 237 CNemore » and the 10 known RNe, as well as exhaustive discovery efficiency records. We recognize RNe as having (1) outburst amplitude smaller than 14.5 – 4.5 × log (t {sub 3}), (2) orbital period >0.6 days, (3) infrared colors of J – H > 0.7 mag and H – K > 0.1 mag, (4) FWHM of Hα > 2000 km s{sup –1}, (5) high excitation lines, such as Fe X or He II near peak, (6) eruption light curves with a plateau, and (7) white dwarf mass greater than 1.2 M {sub ☉}. Using these criteria, we identify V1721 Aql, DE Cir, CP Cru, KT Eri, V838 Her, V2672 Oph, V4160 Sgr, V4643 Sgr, V4739 Sgr, and V477 Sct as strong RN candidates. We evaluate the RN fraction among the known CNe using three methods to get 24% ± 4%, 12% ± 3%, and 35% ± 3%. With roughly a quarter of the 394 known Galactic novae actually being RNe, there should be approximately a hundred such systems masquerading as CNe.« less
DAIDALUS Observations From UAS Integration in the NAS Project Flight Test 4
NASA Technical Reports Server (NTRS)
Vincent, Michael J.; Tsakpinis, Dimitrios
2016-01-01
In order to validate the Unmanned Aerial System (UAS) Detect-and-Avoid (DAA) solution proposed by standards body RTCA Inc., the National Aeronautics and Space Administration (NASA) UAS Integration in the NAS project, alongside industry members General Atomics and Honeywell, conducted the fourth flight test in a series at Armstrong Flight Research Center in Edwards, California. Flight Test 4 (FT4) investigated problems of interoperability with the TCAS collision avoidance system with a DAA system as well as problems associated with sensor uncertainty. A series of scripted flight encounters between the NASA Ikhana UAS and various "intruder" aircraft were flown while alerting and guidance from the DAA algorithm were recorded to investigate the timeliness of the alerts and correctness of the guidance triggered by the DAA system. The results found that alerts were triggered in a timely manner in most instances. Cases where the alerting and guidance was incorrect were investigated further.
Wolf, Matthew; Miller, Suzanne; DeJong, Doug; House, John A; Dirks, Carl; Beasley, Brent
2016-09-01
To establish a process for the development of a prioritization tool for a clinical decision support build within a computerized provider order entry system and concurrently to prioritize alerts for Saint Luke's Health System. The process of prioritizing clinical decision support alerts included (a) consensus sessions to establish a prioritization process and identify clinical decision support alerts through a modified Delphi process and (b) a clinical decision support survey to validate the results. All members of our health system's physician quality organization, Saint Luke's Care as well as clinicians, administrators, and pharmacy staff throughout Saint Luke's Health System, were invited to participate in this confidential survey. The consensus sessions yielded a prioritization process through alert contextualization and associated Likert-type scales. Utilizing this process, the clinical decision support survey polled the opinions of 850 clinicians with a 64.7 percent response rate. Three of the top rated alerts were approved for the pre-implementation build at Saint Luke's Health System: Acute Myocardial Infarction Core Measure Sets, Deep Vein Thrombosis Prophylaxis within 4 h, and Criteria for Sepsis. This study establishes a process for developing a prioritization tool for a clinical decision support build within a computerized provider order entry system that may be applicable to similar institutions. © The Author(s) 2015.
Real time alert system: a disease management system leveraging health information exchange.
Anand, Vibha; Sheley, Meena E; Xu, Shawn; Downs, Stephen M
2012-01-01
Rates of preventive and disease management services can be improved by providing automated alerts and reminders to primary care providers (PCPs) using of health information technology (HIT) tools. Using Adaptive Turnaround Documents (ATAD), an existing Health Information Exchange (HIE) infrastructure and office fax machines, we developed a Real Time Alert (RTA) system. RTA is a computerized decision support system (CDSS) that is able to deliver alerts to PCPs statewide for recommended services around the time of the patient visit. RTA is also able to capture structured clinical data from providers using existing fax technology. In this study, we evaluate RTA's performance for alerting PCPs when their patients with asthma have an emergency room visit anywhere in the state. Our results show that RTA was successfully able to deliver "just in time" patient-relevant alerts to PCPs across the state. Furthermore, of those ATADs faxed back and automatically interpreted by the RTA system, 35% reported finding the provided information helpful. The PCPs who reported finding information helpful also reported making a phone call, sending a letter or seeing the patient for follow up care. We have successfully demonstrated the feasibility of electronically exchanging important patient related information with the PCPs statewide. This is despite a lack of a link with their electronic health records. We have shown that using our ATAD technology, a PCP can be notified quickly of an important event such as a patient's asthma related emergency room admission so further follow up can happen in near real time.
Carbamates and ICH M7 classification: Making use of expert knowledge.
Hemingway, Rachel; Fowkes, Adrian; Williams, Richard V
2017-06-01
Carbamates are widely used in the chemical industry so understanding their toxicity is important to safety assessment. Carbamates have been associated with certain toxicities resulting in publication of structural alerts, including alerts for mutagenicity. Structural alerts for bacterial mutagenicity can be used in combination with statistical systems to enable ICH M7 classification, which allows assessment of the genotoxic risk posed by pharmaceutical impurities. This study tested a hypothetical bacterial mutagenicity alert for carbamates and examined the impact it would have on ICH M7 classifications using (Q)SAR predictions from the expert rule-based system Derek Nexus and the statistical-based system Sarah Nexus. Public datasets have a low prevalence of mutagenic carbamates, which highlighted that systems containing an alert for carbamates perform poorly for achieving correct ICH M7 classifications. Carbamates are commonly used as protecting groups and proprietary datasets containing such compounds were also found to have a low prevalence of mutagenic compounds. Expert review of the mutagenic compounds established that mutagenicity was often only observed under certain (non-standard) conditions and more generally that the Ames test may be a poor predictor for the risk of carcinogenicity posed by chemicals in this class. Overall a structural alert for the in vitro bacterial mutagenesis of carbamates does not benefit workflows for assigning ICH M7 classification to impurities. Crown Copyright © 2017. Published by Elsevier Inc. All rights reserved.
Using Heuristic Evaluation to Improve Sepsis Alert Usability.
Pertiwi, Ariani Arista Putri; Fraczkowski, Dan; Stogis, Sheryl L; Lopez, Karen Dunn
2018-06-01
Sepsis, life-threatening organ dysfunction in response to infection, is an alarmingly common and aggressive illness in US hospitals, especially for intensive care patients. Preventing sepsis deaths rests on the clinicians' ability to promptly recognize and treat sepsis. To aid early recognition, many organizations have employed clinician-facing electronic sepsis alert systems. However, the effectiveness of the alert relies on heavily on the visual interface, textual information, and overall usability. This article reports a usability inspection of a sepsis alert system. The authors found violations in 12 of the 14 usability principles and promote use of this method in practice to systematically identify usability problems. Copyright © 2018 Elsevier Inc. All rights reserved.
NOVA2-mediated RNA regulation is required for axonal pathfinding during development
Saito, Yuhki; Miranda-Rottmann, Soledad; Ruggiu, Matteo; Park, Christopher Y; Fak, John J; Zhong, Ru; Duncan, Jeremy S; Fabella, Brian A; Junge, Harald J; Chen, Zhe; Araya, Roberto; Fritzsch, Bernd; Hudspeth, A J; Darnell, Robert B
2016-01-01
The neuron specific RNA-binding proteins NOVA1 and NOVA2 are highly homologous alternative splicing regulators. NOVA proteins regulate at least 700 alternative splicing events in vivo, yet relatively little is known about the biologic consequences of NOVA action and in particular about functional differences between NOVA1 and NOVA2. Transcriptome-wide searches for isoform-specific functions, using NOVA1 and NOVA2 specific HITS-CLIP and RNA-seq data from mouse cortex lacking either NOVA isoform, reveals that NOVA2 uniquely regulates alternative splicing events of a series of axon guidance related genes during cortical development. Corresponding axonal pathfinding defects were specific to NOVA2 deficiency: Nova2-/- but not Nova1-/- mice had agenesis of the corpus callosum, and axonal outgrowth defects specific to ventral motoneuron axons and efferent innervation of the cochlea. Thus we have discovered that NOVA2 uniquely regulates alternative splicing of a coordinate set of transcripts encoding key components in cortical, brainstem and spinal axon guidance/outgrowth pathways during neural differentiation, with severe functional consequences in vivo. DOI: http://dx.doi.org/10.7554/eLife.14371.001 PMID:27223325
Predictive Information: Status or Alert Information?
NASA Technical Reports Server (NTRS)
Trujillo, Anna C.; Bruneau, Daniel; Press, Hayes N.
2008-01-01
Previous research investigating the efficacy of predictive information for detecting and diagnosing aircraft system failures found that subjects like to have predictive information concerning when a parameter would reach an alert range. This research focused on where the predictive information should be located, whether the information should be more closely associated with the parameter information or with the alert information. Each subject saw 3 forms of predictive information: (1) none, (2) a predictive alert message, and (3) predictive information on the status display. Generally, subjects performed better and preferred to have predictive information available although the difference between status and alert predictive information was minimal. Overall, for detection and recalling what happened, status predictive information is best; however for diagnosis, alert predictive information holds a slight edge.
PubMedAlertMe - Standalone Windows-based PubMed SDI Software Application
Ma’ayan, Avi
2008-01-01
PubMedAlertMe is a Windows-based software system for automatically receiving e-mail alert messages about recent publications listed on PubMed. The e-mail messages contain links to newly available abstracts listed on PubMed describing publications that were selectively returned from a specified list of queries. Links are also provided to directly export citations to EndNote, and links are provided to directly forward articles to colleagues. The program is standalone. Thus, it does not require a remote mail server or user registration. PubMedAlertMe is free software, and can be downloaded from: http://amp.pharm.mssm.edu/PubMedAlertMe/PubMedAlertMe_setup.zip PMID:18402930
Implementing a Commercial Rule Base as a Medication Order Safety Net
Reichley, Richard M.; Seaton, Terry L.; Resetar, Ervina; Micek, Scott T.; Scott, Karen L.; Fraser, Victoria J.; Dunagan, W. Claiborne; Bailey, Thomas C.
2005-01-01
A commercial rule base (Cerner Multum) was used to identify medication orders exceeding recommended dosage limits at five hospitals within BJC HealthCare, an integrated health care system. During initial testing, clinical pharmacists determined that there was an excessive number of nuisance and clinically insignificant alerts, with an overall alert rate of 9.2%. A method for customizing the commercial rule base was implemented to increase rule specificity for problematic rules. The system was subsequently deployed at two facilities and achieved alert rates of less than 1%. Pharmacists screened these alerts and contacted ordering physicians in 21% of cases. Physicians made therapeutic changes in response to 38% of alerts presented to them. By applying simple techniques to customize rules, commercial rule bases can be used to rapidly deploy a safety net to screen drug orders for excessive dosages, while preserving the rule architecture for later implementations of more finely tuned clinical decision support. PMID:15802481
Sathishkumar, Subramanian; Lai, Manda; Picton, Paul; Kheterpal, Sachin; Morris, Michelle; Shanks, Amy; Ramachandran, Satya Krishna
2015-07-01
Hyperglycemia, defined as blood glucose (BG) levels above 200 mg/dl (11.1 mM), is associated with increased postoperative morbidity. Yet, the treatment standard for intraoperative glycemic control is poorly defined for noncardiac surgery. Little is known of the interindividual treatment variability or methods to modify intraoperative glycemic management behaviors. AlertWatch (AlertWatch, USA) is a novel audiovisual alert system that serves as a secondary patient monitor for use in operating rooms. The authors evaluated the influence of use of AlertWatch on intraoperative glycemic management behavior. AlertWatch displays historical patient data (risk factors and laboratory results) from multiple networked information systems, combined with the patient's live physiologic data. The authors extracted intraoperative data for 19 months to evaluate the relationship between AlertWatch usage and initiation of insulin treatment for hyperglycemia. Outcome associations were adjusted for physical status, case duration, procedural complexity, emergent procedure, fasting BG value, home insulin therapy, patient age, and primary anesthetist. Overall, 2,341 patients had documented intraoperative hyperglycemia. Use of AlertWatch (791 of 2,341; 33.5%) was associated with 55% increase in insulin treatment (496 of 791 [62.7%] with and 817 of 1,550 [52.7%] without AlertWatch; adjusted odds ratio [95% CI], 1.55 [1.23 to 1.95]; P < 0.001) and 44% increase in BG recheck after insulin administration (407 of 791 [51.5%] with AlertWatch and 655 of 1,550 [42.3%] in controls; adjusted odds ratio [95% CI], 1.44 [1.14 to 1.81]; P = 0.002). AlertWatch is associated with a significant increase in desirable intraoperative glycemic management behavior and may help achieve tighter intraoperative glycemic control.
Hoste, Eric A J; Kashani, Kianoush; Gibney, Noel; Wilson, F Perry; Ronco, Claudio; Goldstein, Stuart L; Kellum, John A; Bagshaw, Sean M
2016-01-01
Among hospitalized patients, acute kidney injury is common and associated with significant morbidity and risk for mortality. The use of electronic health records (EHR) for prediction and detection of this important clinical syndrome has grown in the past decade. The steering committee of the 15(th) Acute Dialysis Quality Initiative (ADQI) conference dedicated a workgroup with the task of identifying elements that may impact the course of events following Acute Kidney Injury (AKI) e-alert. Following an extensive, non-systematic literature search, we used a modified Delphi process to reach consensus regarding several aspects of the utilization of AKI e-alerts. Topics discussed in this workgroup included progress in evidence base practices, the characteristics of an optimal e-alert, the measures of efficacy and effectiveness, and finally what responses would be considered best practices following AKI e-alerts. Authors concluded that the current evidence for e-alert system efficacy, although growing, remains insufficient. Technology and human-related factors were found to be crucial elements of any future investigation or implementation of such tools. The group also concluded that implementation of such systems should not be done without a vigorous plan to evaluate the efficacy and effectiveness of e-alerts. Efficacy and effectiveness of e-alerts should be measured by context-specific process and patient outcomes. Finally, the group made several suggestions regarding the clinical decision support that should be considered following successful e-alert implementation. This paper reflects the findings of a non-systematic review and expert opinion. We recommend implementation of the findings of this workgroup report for use of AKI e-alerts.
ASASSN-17fp rebrightening event and ongoing monitoring
NASA Astrophysics Data System (ADS)
Waagen, Elizabeth O.
2017-05-01
ASASSN-17fp, discovered on 2017 April 28 and classified as a helium dwarf nova, was observed to be in outburst again on May 16 after fading 2.5 magnitudes from its original outburst. Dr. Tom Marsh (University of Warwick) and Dr. Elme Breedt (University of Cambridge) requested immediate time-series coverage. Dr. Breedt wrote: "The transient was identified as a helium dwarf nova (also known as an AMCVn star) from a spectrum taken by the PESSTO survey and reported in ATel #10334. Since then, we have been observing the target using the New Technology Telescope on La Silla in Chile. We measured a photometric period of 51 minutes in the first few nights during which the object was bright at g=16.03 (Marsh et al., ATel #10354), and then it faded to about g 18. However last night [ May 16] it brightened back to g 16 again, apparently starting a second outburst. Time series observations during this bright state would be very valuable to determine whether the 51 min period we saw in earlier data returns, and whether it is the orbital period of the binary or related to the distortion of the accretion disc in outburst (superhumps). If the 51 min signal is the orbital period or close to it, this would be the helium dwarf nova with the longest orbital period known. Multiple successive outbursts are not uncommon in binaries like this..." Observers should continue to monitor ASASSN-17fp with nightly snapshots for two weeks after it fades, in case it rebrightens again. It appears to have faded, according to an observation in the AAVSO International Database by F.-J. Hambsch (HMB, Mol, Belgium), who observed it remotely from Chile on 2017 May 24.2252 UT at magnitude 19.944 CV ± 0.595. Continue nightly snapshots through June 6 at least, and if it brightens again, resume time series. Finder charts with sequence may be created using the AAVSO Variable Star Plotter (https://www.aavso.org/vsp). Observations should be submitted to the AAVSO International Databa! se. See full Alert Notice for more details.
Alerts in mobile healthcare applications: requirements and pilot study.
Kafeza, Eleanna; Chiu, Dickson K W; Cheung, S C; Kafeza, Marina
2004-06-01
Recent advances in mobile technologies have greatly extended traditional communication technologies to mobile devices. At the same time, healthcare environments are by nature "mobile" where doctors and nurses do not have fixed workspaces. Irregular and exceptional events are generated in daily hospital routines, such as operations rescheduling, laboratory/examination results, and adverse drug events. These events may create requests that should be delivered to the appropriate person at the appropriate time. Those requests that are classified as urgent are referred to as alerts. Efficient routing and monitoring of alerts are keys to quality and cost-effective healthcare services. Presently, these are generally handled in an ad hoc manner. In this paper, we propose the use of a healthcare alert management system to handle these alert messages systematically. We develop a model for specifying alerts that are associated with medical tasks and a set of parameters for their routing. We design an alert monitor that matches medical staff and their mobile devices to receive alerts, based on the requirements of these alerts. We also propose a mechanism to handle and reroute, if necessary, an alert message when it has not been acknowledged within a specific deadline.
Evaluation of Helmet Mounted Display Alerting Symbology
NASA Technical Reports Server (NTRS)
DeMaio, Joe; Rutkowski, Michael (Technical Monitor)
2000-01-01
Proposed helicopter helmet mounted displays will be used to alert the pilot to a variety of conditions, from threats to equipment problems. The present research was performed under the NASA Safe All-weather Flight Operations Research (SAFOR) program supported by a joint Army/NASA research agreement. The purpose of the research was to examine ways to optimize the alerting effectiveness of helmet display symbology. The research used two approaches to increasing the effectiveness of alerts. One was to increase the ability of the alert to attract attention by using the entire display surface. The other was to include information about the required response in the alert itself. The investigation was conducted using the NASA Ames Research Center's six-degree-of-freedom vertical motion simulator (VMS) with a rotorcraft cockpit. Helmet display symbology was based on the AH-64's pilot night vision system (PNVS), cruise mode symbology. A standardized mission was developed, that consisted of 11 legs. The mission included four tasks, which allowed variation in the frequency of alerts. The general trend in the data points to a small benefit from both the full-screen alert and the partial information alert.
Optical and Infrared Spectroscopy of Nova Ophiuchi 2018 No.2
NASA Astrophysics Data System (ADS)
Rudy, R. J.; Mauerhan, J. C.; Russell, R. W.; Subasavage, J. P.; Wiktorowicz, S. J.; Kim, D. L.; Sitko, M. L.
2018-05-01
Over a two week period coming approximately two months after outburst, Nova Ophiuchi 2018, No.2 (CBET 4492) was observed spectroscopically using instruments from three different facilities: 2018 May 6, using the Spex instrument at the Infrared Telescope Facility (0.7-2.5 microns); 2018 May 14, using the Broadband Array Spectrograph System on the 3.6 meter Advanced Electro-Optical Systems telescope (3-13 microns); 2018 May 19, with the VNIRIS spectrograph on the Aerospace Corporation's one meter telescope (0.47-2.5 microns).
On the nature of the nova-like variable CD-42 deg 14462
NASA Technical Reports Server (NTRS)
Guinan, E. F.; Sion, E. M.
1981-01-01
Low dispersion long and short wavelength IUE spectra of the nova like system CD-42 deg 14462 were obtained on August 24 U.T. The short wave spectrum exhibits absorption features due to C III (lambda 1175), Lalpha 1216), NV (lambda1240), HeII (lambda 1640), SiIV (lambda1394), NIV (lambda1875) with CIV (lambda1550) as a P Cygni feature with blue shifted absorption suggesting the presence of material leaving the system. Possible interpretations of this object are discussed.
Evaluation of real-time clinical decision support systems for platelet and cryoprecipitate orders.
Collins, Ryan A; Triulzi, Darrell J; Waters, Jonathan H; Reddy, Vivek; Yazer, Mark H
2014-01-01
To evaluate cryoprecipitate and platelet ordering practices after the implementation of real-time clinical decision support systems (CDSSs) in a computerized physician order entry (CPOE) system. Uniform platelet and cryoprecipitate transfusion thresholds were implemented at 11 hospitals in a regional health care system with a common CPOE system. Over 6 months, a variety of information was collected on the ordering physicians and the number of alerts generated by the CDSSs when these products were ordered outside of the institutional guidelines. There were 1,889 orders for platelets and 152 orders for cryoprecipitate placed in 6 months. Of these, 1,102 (58.3%) platelet and 74 (48.7%) cryoprecipitate orders triggered an alert. The proportion of orders canceled after an alert was generated ranged from 13.5% to 17.9% for platelets and 0% to 50.0% for cryoprecipitate orders. CDSS alerts reduce, but do not eliminate, platelet and cryoprecipitate transfusions that do not meet institutional guidelines.
Knowledge Integration and Use-Case Analysis for a Customized Drug-Drug Interaction CDS Service
NASA Astrophysics Data System (ADS)
Kam, Hye Jin; Park, Man Young; Kim, Woojae; Yoon, Duk Yong; Ahn, Eun Kyoung; Park, Rae Woong
Clinical decision support systems (CDSSs) are thought to reduce adverse drug events (ADEs) by monitoring drug-drug interactions(DDIs). However, clinically improper or excessive alerts can result in high alert overrides. A tailored CDS service, which is appropriate for clinicians and their ordering situations, is required to increase alert acceptance. In this study, we conducted a 12-week pilot project adopting a tailed CDSS at an emergency department. The new CDSS was conducted via a stepwise integration of additional new rules. The alert status with changes in acceptance rate was analyzed. The most frequent DDI alerts were related to prescriptions of anti-inflammatory drugs. The percentages of alert overrides for each stage were 98.0%, 96.0%, 96.9%, and 98.1%, respectively. 91.5% of overridden alerts were related to discharge medications. To reduce the potential hazards of ADEs, the development of an effective customized DDI CDSS is required, via in-depth analysis on alert patterns and overridden reasons.
75 FR 4760 - Review of the Emergency Alert System
Federal Register 2010, 2011, 2012, 2013, 2014
2010-01-29
...; State, Local or Tribal Governments; Non-profit entities. Number of Respondents: 3,569,028. Estimated... hours. Total Annual Cost: $3,086,044. Privacy Impact Assessment: No impact(s). Nature and Extent of... retransmitted the alert; and (3) if they were not able to receive and/ or transmit the alert, their `best effort...
An approach for representing sensor data to validate alerts in Ambient Assisted Living.
Muñoz, Andrés; Serrano, Emilio; Villa, Ana; Valdés, Mercedes; Botía, Juan A
2012-01-01
The mainstream of research in Ambient Assisted Living (AAL) is devoted to developing intelligent systems for processing the data collected through artificial sensing. Besides, there are other elements that must be considered to foster the adoption of AAL solutions in real environments. In this paper we focus on the problem of designing interfaces among caregivers and AAL systems. We present an alert management tool that supports carers in their task of validating alarms raised by the system. It generates text-based explanations--obtained through an argumentation process--of the causes leading to alarm activation along with graphical sensor information and 3D models, thus offering complementary types of information. Moreover, a guideline to use the tool when validating alerts is also provided. Finally, the functionality of the proposed tool is demonstrated through two real cases of alert.
Yazer, Mark H; Triulzi, Darrell J; Reddy, Vivek; Waters, Jonathan H
2013-12-01
We investigated the effect of implementing adaptive plasma ordering criteria in the computerized physician order entry (CPOE) system, with alerts that were automatically generated if the recipient's antecedent international normalized ratio (INR) did not meet the institutional criteria. In a regional health care system consisting of 11 hospitals using a common CPOE, data on the number of plasma orders and alerts that were generated were collected over a 4-month period before prescribers were required to select an indication for plasma. When adaptive ordering was implemented prescribers had to choose from prepopulated indications for plasma: INR of 1.6 or greater with bleeding, INR of 1.6 or greater before an invasive procedure, therapeutic exchange, massive transfusion, and other. Regardless of the antecedent INR the alert did not trigger if massive transfusion or plasmapheresis was selected. Information on prescribers and recipients was collected during this 5-month period. In the 4-month period before the adaptive alerts were implemented, 42.9% of the plasma orders generated an alert; in the 5-month period thereafter the alert rate was significantly lower at 27.9% (p < 0.0001). The percentage of heeded alerts increased during the adaptive alert period (24.3% vs. 17.1%, respectively, p = 0.004). A significant percentage (45%) of other plasma orders were for periprocedure or bleeding patients whose antecedent INR was less than 1.6. There were significant differences in prescriber specialties among those who ordered plasma using the other indication compared to all plasma orders. Electronic interventions improve compliance with plasma guidelines but as implemented are not sufficient to completely curtail non-evidence-based ordering. © 2013 American Association of Blood Banks.
Lacson, Ronilda; O'Connor, Stacy D; Andriole, Katherine P; Prevedello, Luciano M; Khorasani, Ramin
2014-11-01
Communicating critical results of diagnostic imaging procedures is a national patient safety goal. The purposes of this study were to describe the system architecture and design of Alert Notification of Critical Results (ANCR), an automated system designed to facilitate communication of critical imaging results between care providers; to report providers' satisfaction with ANCR; and to compare radiologists' and ordering providers' attitudes toward ANCR. The design decisions made for each step in the alert communication process, which includes user authentication, alert creation, alert communication, alert acknowledgment and management, alert reminder and escalation, and alert documentation, are described. To assess attitudes toward ANCR, internally developed and validated surveys were administered to all radiologists (n = 320) and ordering providers (n = 4323) who sent or received alerts 3 years after ANCR implementation. The survey response rates were 50.4% for radiologists and 36.1% for ordering providers. Ordering providers were generally dissatisfied with the training received for use of ANCR and with access to technical support. Radiologists were more satisfied with documenting critical result communication (61.1% vs 43.2%; p = 0.0001) and tracking critical results (51.6% vs 35.1%; p = 0.0003) than were ordering providers. Both groups agreed use of ANCR reduces medical errors and improves the quality of patient care. Use of ANCR enables automated communication of critical test results. The survey results confirm overall provider satisfaction with ANCR but highlight the need for improved training strategies for large numbers of geographically dispersed ordering providers. Future enhancements beyond acknowledging receipt of critical results are needed to help ensure timely and appropriate follow-up of critical results to improve quality and patient safety.
Lacson, Ronilda; O'Connor, Stacy D.; Andriole, Katherine P.; Prevedello, Luciano M.; Khorasani, Ramin
2015-01-01
OBJECTIVE Communicating critical results of diagnostic imaging procedures is a national patient safety goal. The purposes of this study were to describe the system architecture and design of Alert Notification of Critical Results (ANCR), an automated system designed to facilitate communication of critical imaging results between care providers; to report providers’ satisfaction with ANCR; and to compare radiologists’ and ordering providers’ attitudes toward ANCR. MATERIALS AND METHODS The design decisions made for each step in the alert communication process, which includes user authentication, alert creation, alert communication, alert acknowledgment and management, alert reminder and escalation, and alert documentation, are described. To assess attitudes toward ANCR, internally developed and validated surveys were administered to all radiologists (n = 320) and ordering providers (n = 4323) who sent or received alerts 3 years after ANCR implementation. RESULTS The survey response rates were 50.4% for radiologists and 36.1% for ordering providers. Ordering providers were generally dissatisfied with the training received for use of ANCR and with access to technical support. Radiologists were more satisfied with documenting critical result communication (61.1% vs 43.2%; p = 0.0001) and tracking critical results (51.6% vs 35.1%; p = 0.0003) than were ordering providers. Both groups agreed use of ANCR reduces medical errors and improves the quality of patient care. CONCLUSION Use of ANCR enables automated communication of critical test results. The survey results confirm overall provider satisfaction with ANCR but highlight the need for improved training strategies for large numbers of geographically dispersed ordering providers. Future enhancements beyond acknowledging receipt of critical results are needed to help ensure timely and appropriate follow-up of critical results to improve quality and patient safety. PMID:25341163
Combining Surveillance Systems: Effective Merging of U.S. Veteran and Military Health Data
2016-08-04
respectively, and better in VA data for 34% and 15%. The VA system tended to alert earlier with a typical H3N2 seasonal influenza affecting older...manageable effect on customary alert rates. Citation: Pavlin JA, Burkom HS, Elbert Y, Lucero-Obusan C, Winston CA, et al. (2013) Combining...facilities within the CBSA. We applied ESSENCE alerting algorithms [11] to weekly CBSA-level outpatient data and analyzed the two data streams (DoD and VA
Radhakrishna, K.; Bowles, K.; Zettek-Sumner, A.
2013-01-01
Summary Background Telehealth data overload through high alert generation is a significant barrier to sustained adoption of telehealth for managing HF patients. Objective To explore the factors contributing to frequent telehealth alerts including false alerts for Medicare heart failure (HF) patients admitted to a home health agency. Materials and Methods A mixed methods design that combined quantitative correlation analysis of patient characteristic data with number of telehealth alerts and qualitative analysis of telehealth and visiting nurses’ notes on follow-up actions to patients’ telehealth alerts was employed. All the quantitative and qualitative data was collected through retrospective review of electronic records of the home heath agency. Results Subjects in the study had a mean age of 83 (SD = 7.6); 56% were female. Patient co-morbidities (p<0.05) of renal disorders, anxiety, and cardiac arrhythmias emerged as predictors of telehealth alerts through quantitative analysis (n = 168) using multiple regression. Inappropriate telehealth measurement technique by patients (54%) and home healthcare system inefficiencies (37%) contributed to most telehealth false alerts in the purposive qualitative sub-sample (n = 35) of patients with high telehealth alerts. Conclusion Encouraging patient engagement with the telehealth process, fostering a collaborative approach among all the clinicians involved with the telehealth intervention, tailoring telehealth alert thresholds to patient characteristics along with establishing patient-centered telehealth outcome goals may allow meaningful generation of telehealth alerts. Reducing avoidable telehealth alerts could vastly improve the efficiency and sustainability of telehealth programs for HF management. PMID:24454576
Hwang, Yeonsoo; Yoon, Dukyong; Ahn, Eun Kyoung; Hwang, Hee; Park, Rae Woong
2016-12-01
To determine the risk factors and rate of medication administration error (MAE) alerts by analyzing large-scale medication administration data and related error logs automatically recorded in a closed-loop medication administration system using radio-frequency identification and barcodes. The subject hospital adopted a closed-loop medication administration system. All medication administrations in the general wards were automatically recorded in real-time using radio-frequency identification, barcodes, and hand-held point-of-care devices. MAE alert logs recorded during a full 1 year of 2012. We evaluated risk factors for MAE alerts including administration time, order type, medication route, the number of medication doses administered, and factors associated with nurse practices by logistic regression analysis. A total of 2 874 539 medication dose records from 30 232 patients (882.6 patient-years) were included in 2012. We identified 35 082 MAE alerts (1.22% of total medication doses). The MAE alerts were significantly related to administration at non-standard time [odds ratio (OR) 1.559, 95% confidence interval (CI) 1.515-1.604], emergency order (OR 1.527, 95%CI 1.464-1.594), and the number of medication doses administered (OR 0.993, 95%CI 0.992-0.993). Medication route, nurse's employment duration, and working schedule were also significantly related. The MAE alert rate was 1.22% over the 1-year observation period in the hospital examined in this study. The MAE alerts were significantly related to administration time, order type, medication route, the number of medication doses administered, nurse's employment duration, and working schedule. The real-time closed-loop medication administration system contributed to improving patient safety by preventing potential MAEs. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
Using electronic health record alerts to provide public health situational awareness to clinicians.
Lurio, Joseph; Morrison, Frances P; Pichardo, Michelle; Berg, Rachel; Buck, Michael D; Wu, Winfred; Kitson, Kwame; Mostashari, Farzad; Calman, Neil
2010-01-01
Alerting providers to public health situations requires timeliness and context-relevance, both lacking in current systems. Incorporating decision support tools into electronic health records may provide a way to deploy public health alerts to clinicians at the point of care. A timely process for responding to Health Alert Network messages sent by the New York City Department of Health and Mental Hygiene was developed by a network of community health centers. Alerts with order sets and recommended actions were created to notify primary care providers of local disease outbreaks. The process, effect, and lessons learned from alerts for Legionella, toxogenic E coli, and measles outbreaks are described. Electronic alerts have the potential to improve management of diseases during an outbreak, including appropriate laboratory testing, management guidance, and diagnostic assistance as well as to enhance bi-directional data exchange between clinical and public health organizations.
Using electronic health record alerts to provide public health situational awareness to clinicians
Lurio, Joseph; Pichardo, Michelle; Berg, Rachel; Buck, Michael D; Wu, Winfred; Kitson, Kwame; Mostashari, Farzad; Calman, Neil
2010-01-01
Alerting providers to public health situations requires timeliness and context-relevance, both lacking in current systems. Incorporating decision support tools into electronic health records may provide a way to deploy public health alerts to clinicians at the point of care. A timely process for responding to Health Alert Network messages sent by the New York City Department of Health and Mental Hygiene was developed by a network of community health centers. Alerts with order sets and recommended actions were created to notify primary care providers of local disease outbreaks. The process, effect, and lessons learned from alerts for Legionella, toxogenic E coli, and measles outbreaks are described. Electronic alerts have the potential to improve management of diseases during an outbreak, including appropriate laboratory testing, management guidance, and diagnostic assistance as well as to enhance bi-directional data exchange between clinical and public health organizations. PMID:20190067
Computerized Alerts Improve Outpatient Laboratory Monitoring of Transplant Patients
Staes, Catherine J.; Evans, R. Scott; Rocha, Beatriz H.S.C.; Sorensen, John B.; Huff, Stanley M.; Arata, Joan; Narus, Scott P.
2008-01-01
Authors evaluated the impact of computerized alerts on the quality of outpatient laboratory monitoring for transplant patients. For 356 outpatient liver transplant patients managed at LDS Hospital, Salt Lake City, this observational study compared traditional laboratory result reporting, using faxes and printouts, to computerized alerts implemented in 2004. Study alerts within the electronic health record notified clinicians of new results and overdue new orders for creatinine tests and immunosuppression drug levels. After implementing alerts, completeness of reporting increased from 66 to >99 %, as did positive predictive value that a report included new information (from 46 to >99 %). Timeliness of reporting and clinicians' responses improved after implementing alerts (p <0.001): median times for clinicians to receive and complete actions decreased to 9 hours from 33 hours using the prior traditional reporting system. Computerized alerts led to more efficient, complete, and timely management of laboratory information. PMID:18308982
Vehicle proximity alert system for highway-railroad grade crossings-prototype research
DOT National Transportation Integrated Search
2001-04-01
This report describes testing of prototype vehicle proximity alert system (VPAS) technologies, and presents and evaluates the results. The object was to determine the feasibility of VPAS for possible use in priority vehicles (i.e., emergency vehicles...
AT Cnc: A SECOND DWARF NOVA WITH A CLASSICAL NOVA SHELL
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shara, Michael M.; Mizusawa, Trisha; Zurek, David
2012-10-20
We are systematically surveying all known and suspected Z Cam-type dwarf novae for classical nova shells. This survey is motivated by the discovery of the largest known classical nova shell, which surrounds the archetypal dwarf nova Z Camelopardalis. The Z Cam shell demonstrates that at least some dwarf novae must have undergone classical nova eruptions in the past, and that at least some classical novae become dwarf novae long after their nova thermonuclear outbursts, in accord with the hibernation scenario of cataclysmic binaries. Here we report the detection of a fragmented 'shell', 3 arcmin in diameter, surrounding the dwarf novamore » AT Cancri. This second discovery demonstrates that nova shells surrounding Z Cam-type dwarf novae cannot be very rare. The shell geometry is suggestive of bipolar, conical ejection seen nearly pole-on. A spectrum of the brightest AT Cnc shell knot is similar to that of the ejecta of the classical nova GK Per, and of Z Cam, dominated by [N II] emission. Galaxy Evolution Explorer FUV imagery reveals a similar-sized, FUV-emitting shell. We determine a distance of 460 pc to AT Cnc, and an upper limit to its ejecta mass of {approx}5 Multiplication-Sign 10{sup -5} M {sub Sun }, typical of classical novae.« less
Engine monitoring display study
NASA Technical Reports Server (NTRS)
Hornsby, Mary E.
1992-01-01
The current study is part of a larger NASA effort to develop displays for an engine-monitoring system to enable the crew to monitor engine parameter trends more effectively. The objective was to evaluate the operational utility of adding three types of information to the basic Boeing Engine Indicating and Crew Alerting System (EICAS) display formats: alphanumeric alerting messages for engine parameters whose values exceed caution or warning limits; alphanumeric messages to monitor engine parameters that deviate from expected values; and a graphic depiction of the range of expected values for current conditions. Ten training and line pilots each flew 15 simulated flight scenarios with five variants of the basic EICAS format; these variants included different combinations of the added information. The pilots detected engine problems more quickly when engine alerting messages were included in the display; adding a graphic depiction of the range of expected values did not affect detection speed. The pilots rated both types of alphanumeric messages (alert and monitor parameter) as more useful and easier to interpret than the graphic depiction. Integrating engine parameter messages into the EICAS alerting system appears to be both useful and preferred.
NASA Astrophysics Data System (ADS)
White, Robert R.; Wren, James; Davis, Heath R.; Galassi, Mark; Starr, Daniel; Vestrand, W. T.; Wozniak, P.
2004-09-01
The internet has brought about great change in the astronomical community, but this interconnectivity is just starting to be exploited for use in instrumentation. Utilizing the internet for communicating between distributed astronomical systems is still in its infancy, but it already shows great potential. Here we present an example of a distributed network of telescopes that performs more efficiently in synchronous operation than as individual instruments. RAPid Telescopes for Optical Response (RAPTOR) is a system of telescopes at LANL that has intelligent intercommunication, combined with wide-field optics, temporal monitoring software, and deep-field follow-up capability all working in closed-loop real-time operation. The Telescope ALert Operations Network (TALON) is a network server that allows intercommunication of alert triggers from external and internal resources and controls the distribution of these to each of the telescopes on the network. TALON is designed to grow, allowing any number of telescopes to be linked together and communicate. Coupled with an intelligent alert client at each telescope, it can analyze and respond to each distributed TALON alert based on the telescopes needs and schedule.
[Health alert management and emerging risk].
Pillonel, J
2010-12-01
Following health crisis that have occurred in the nineties (contaminated blood, mad cow, asbestos, etc.) and more recently those generated by the heat wave in 2003 or by emerging infectious pathogens (SARS, West Nile, Chikungunya, H5N1, H1N1…), a real health vigilance system has been progressively developed in France. After a brief historical overview of the health alert system, this article will give the guiding principles of its current organization in France and will present two examples of recent health alerts (Chikungunya in the Reunion Island in 2005-2006 and hepatitis A outbreak in the Côtes-d'Armor in August 2007), that have needed the implementation of preventive measures regarding the blood donor selection. These two examples have shown that the position of the alert in the French health vigilance system needs to be very close to the event. In that case, health alert is a very useful tool for decision making especially when measures have to be taken to prevent transfusion-transmitted pathogens. Copyright © 2010 Elsevier Masson SAS. All rights reserved.
2017-09-01
analyzing Snort alerts. The first section covers the Snort alert-generation program, the methodology involved in developing it, and how it accelerates...guide on system setup. The methodologies described can be translated to the setup and use of the ELK stack for storing and visualizing any data...Figures iv List of Tables iv 1. Introduction 1 2. Methodology 2 2.1. Snort Alert Generation 2 2.2 The SELK Stack 8 3. Discussion and Conclusion 11
Polidori, Piera; Di Giorgio, Concetta; Provenzani, Alessio
2012-01-01
Adverse drug events may occur as a result of drug-drug interactions (DDIs). Information technology (IT) systems can be an important decision-making tool for healthcare workers to identify DDIs. The aim of the study is to analyse drug prescriptions in our main hospital units, in order to measure the incidence and severity of potential DDIs. The utility of clinical decision-support systems (CDSSs) and computerised physician order entry (CPOE) in term of alerts adherence was also assessed. DDIs were assessed using a Micromedex® healthcare series database. The system, adopted by the hospital, generates alerts for prescriptions with negative interactions and thanks to an 'acknowledgement function' it is possible to verify physician adherence to alerts. This function, although used previously, became mandatory from September 2010. Physician adherence to alerts and mean monthly incidence of potential DDIs in analysed units, before and after the mandatory 'acknowledgement function', were calculated. The intensive care unit (ICU) registered the greatest incidence of potential DDIs (49.0%), followed by the abdominal surgery unit and dialysis (43.4 and 42.0%, respectively). The cardiothoracic surgery unit (41.6%), step-down unit (38.3%) and post-anaesthesia care unit (30.0%) were comparable. The operating theatre and endoscopy registered the fewest potential DDIs (28.2 and 22.7%, respectively). Adherence to alerts after the 'acknowledgement function' increased by 25.0% in the ICU, 54.0% in the cardiothoracic surgery unit, 52.5% in the abdominal surgery unit, 58.0% in the stepdown unit, 67.0% in dialysis, 51.0% in endoscopy and 48.0% in the post-anaesthesia care unit. In the operating theatre, adherence to alerts decreased from 34.0 to 30.0%. The incidence of potential DDIs after mandatory use of the 'acknowledgement function' decreased slightly in endoscopy (-2.9%), the abdominal surgery unit (-2.7%), dialysis (-1.9%) and the step-down unit (-1.4%). Improving DDI alerts will improved patient safety by more appropriately alerting clinicians.
NASA Astrophysics Data System (ADS)
Ilavajhala, S.; Davies, D.; Schmaltz, J. E.; Wong, M.; Murphy, K. J.
2013-12-01
The NASA Fire Information for Resource Management System (FIRMS) is at the forefront of providing global near real-time (NRT) MODIS thermal anomalies / hotspot location data to end-users . FIRMS serves the data via an interactive Web GIS named Web Fire Mapper, downloads of NRT active fire, archive data downloads for MODIS hotspots dating back to 1999 and a hotspot email alert system The FIRMS Email Alerts system has been successfully alerting users of fires in their area of interest in near real-time and/or via daily and weekly email summaries, with an option to receive MODIS hotspot data as a text file (CSV) attachment. Currently, there are more than 7000 email alert subscriptions from more than 100 countries. Specifically, the email alerts system is designed to generate and send an email alert for any region or area on the globe, with a special focus on providing alerts for protected areas worldwide. For many protected areas, email alerts are particularly useful for early fire detection, monitoring on going fires, as well as allocating resources to protect wildlife and natural resources of particular value. For protected areas, FIRMS uses the World Database on Protected Areas (WDPA) supplied by United Nations Environment Program - World Conservation Monitoring Centre (UNEP-WCMC). Maintaining the most up-to-date, accurate boundary geometry for the protected areas for the email alerts is a challenge as the WDPA is continuously updated due to changing boundaries, merging or delisting of certain protected areas. Because of this dynamic nature of the protected areas database, the FIRMS protected areas database is frequently out-of-date with the most current version of WDPA database. To maintain the most up-to-date boundary information for protected areas and to be in compliance with the WDPA terms and conditions, FIRMS needs to constantly update its database of protected areas. Currently, FIRMS strives to keep its database up to date by downloading the most recent WDPA database at regular intervals, processing it, and ingesting it into the FIRMS spatial database. However, due to the large size of database, the process to download, process and ingest the database is quite time consuming. The FIRMS team is currently working on developing a method to update the protected areas database via web at regular intervals or on-demand. Using such a solution, FIRMS will be able access the most up-to-date extents of any protected area and the corresponding spatial geometries in real time. As such, FIRMS can utilize such a service to access the protected areas and their associated geometries to keep users' protected area boundaries in sync with those of the most recent WDPA database, and thus serve a more accurate email alert to the users. Furthermore, any client accessing the WDPA protected areas database could potentially use the solution of real-time access to the protected areas database. This talk primarily focuses on the challenges for FIRMS in sending accurate email alerts for protected areas, along with the solution the FIRMS team is developing. This talk also introduces the FIRMS fire information system and its components, with a special emphasis on the FIRMS email alerts system.
Survey of Period Variations of Superhumps in SU UMa-Type Dwarf Novae. II The Second Year (2009-2010)
NASA Astrophysics Data System (ADS)
Kato, Taichi; Maehara, Hiroyuki; Uemura, Makoto; Henden, Arne; de Miguel, Enrique; Miller, Ian; Dubovsky, Pavol A.; Kudzej, Igor; Kiyota, Seiichiro; Hambsch, Franz-Josef; Tanabe, Kenji; Imamura, Kazuyoshi; Kunitomi, Nanae; Takagi, Ryosuke; Nose, Mikiha; Akazawa, Hidehiko; Masi, Gianluca; Nakagawa, Shinichi; Iino, Eriko; Noguchi, Ryo; Matsumoto, Katsura; Fujii, Daichi; Kobayashi, Hiroshi; Ogura, Kazuyuki; Ohtomo, Sachi; Yamashita, Kousei; Yanagisawa, Hirofumi; Itoh, Hiroshi; Bolt, Greg; Monard, Berto; Ohshima, Tomohito; Shears, Jeremy; Ruiz, Javier; Imada, Akira; Oksanen, Arto; Nelson, Peter; Gomez, Tomas L.; Staels, Bart; Boyd, David; Voloshina, Irina B.; Krajci, Thomas; Crawford, Tim; Stockdale, Chris; Richmond, Michael; Morelle, Etienne; Novák, Rudolf; Nogami, Daisaku; Ishioka, Ryoko; Brady, Steve; Simonsen, Mike; Pavlenko, Elena P.; Ringwald, Frederick A.; Kuramoto, Tetsuya; Miyashita, Atsushi; Pickard, Roger D.; Hynek, Tomáš; Dvorak, Shawn; Stubbings, Rod; Muyllaert, Eddy
2010-12-01
Continued from Kato et al. (2009, PASJ, 61, S395), we collected the times of superhump maxima for 68 SU UMa-type dwarf novae, mainly observed during the 2009-2010 season. The newly obtained data confirmed the basic findings reported in Kato et al. (ibid.): the presence of stages A-C and the predominance of positive period derivatives during stage B in systems with superhump periods shorter than 0.07 d. There was a systematic difference in the period derivatives for the systems with superhump periods longer than 0.075 d between this study and Kato et al. (ibid.). We suggest that this difference was possibly caused by a relative lack of frequently outbursting SU UMa-type dwarf novae in this period regime in the present study. We recorded a strong beat phenomenon during the 2009 superoutburst of IY UMa. A close correlation between the beat period and the superhump period suggests that the changing angular velocity of the apsidal motion of the elliptical disk is responsible for the variation of the superhump periods. We also described three new WZ Sge-type objects with established early superhumps and one with likely early superhumps. We suggest that two systems, VX For and EL UMa, are WZ Sge-type dwarf novae with multiple rebrightenings. The O - C variation in OT J213806.6+261957 suggests that the frequent absence of rebrightenings in very short-Porb objects can be the result of a sustained superoutburst plateau at the epoch when usual SU UMa-type dwarf novae return to quiescence, preceding a rebrightening. We also present a formulation for a variety of Bayesian extensions to traditional period analyses.
NASA Astrophysics Data System (ADS)
Fonseca, Vinícius Carvalho; Saraiva, Edilson Paes; Maia, Alex Sandro Campos; Nascimento, Carolina Cardoso Nagib; da Silva, Josinaldo Araújo; Pereira, Walter Esfraim; Filho, Edgard Cavalcanti Pimenta; Almeida, Maria Elivânia Vieira
2017-05-01
The aim of this study was to build a prediction model both sensible and latent heat transfer by respiratory tract for Morada Nova sheep under field conditions in a semiarid tropical environment, using easily measured physiological and environmental parameters. Twelve dry Morada Nova ewes with an average of 3 ± 1.2 years old and average body weight of 32.76 ± 3.72 kg were used in a Latin square design 12 × 12 (12 days of records and 12 schedules). Tidal volume, respiratory rate, expired air temperature, and partial vapor pressure of the expired air were obtained from the respiratory facial mask and using a physiological measurement system. Ewes were evaluated from 0700 to 1900 h in each day under shade. A simple nonlinear model to estimate tidal volume as a function of respiratory rate was developed. Equation to estimate the expired air temperature was built, and the ambient air temperature was the best predictor together with relative humidity and ambient vapor pressure. In naturalized Morada Nova sheep, respiratory convection seems to be a mechanism of heat transfer of minor importance even under mild air temperature. Evaporation from the respiratory system increased together with ambient air temperature. At ambient air temperature, up to 35 °C respiratory evaporation accounted 90 % of the total heat lost by respiratory system, on average. Models presented here allow to estimate the heat flow from the respiratory tract for Morada Nova sheep bred in tropical region, using easily measured physiological and environmental traits as respiratory rate, ambient air temperature, and relative humidity.
Data Driven Trigger Design and Analysis for the NOvA Experiment
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kurbanov, Serdar
This thesis primarily describes analysis related to studying the Moon shadow with cosmic rays, an analysis using upward-going muons trigger data, and other work done as part of MSc thesis work conducted at Fermi National Laboratory. While at Fermilab I made hardware and software contributions to two experiments - NOvA and Mu2e. NOvA is a neutrino experiment with the primary goal of measuring parameters related to neutrino oscillation. This is a running experiment, so it's possible to provide analysis of real beam and cosmic data. Most of this work was related to the Data-Driven Trigger (DDT) system of NOvA. Themore » results of the Upward-Going muon analysis was presented at ICHEP in August 2016. The analysis demonstrates the proof of principle for a low-mass dark matter search. Mu2e is an experiment currently being built at Fermilab. Its primary goal is to detect the hypothetical neutrinoless conversion from a muon into an electron. I contributed to the production and tests of Cathode Strip Chambers (CSCs) which are required for testing the Cosmic Ray Veto (CRV) system for the experiment. This contribution is described in the last chapter along with a short description of the technical work provided for the DDT system of the NOvA experiment. All of the work described in this thesis will be extended by the next generation of UVA graduate students and postdocs as new data is collected by the experiment. I hope my eorts of have helped lay the foundation for many years of beautiful results from Mu2e and NOvA.« less
Wearable Smart System for Visually Impaired People
2018-01-01
In this paper, we present a wearable smart system to help visually impaired persons (VIPs) walk by themselves through the streets, navigate in public places, and seek assistance. The main components of the system are a microcontroller board, various sensors, cellular communication and GPS modules, and a solar panel. The system employs a set of sensors to track the path and alert the user of obstacles in front of them. The user is alerted by a sound emitted through a buzzer and by vibrations on the wrist, which is helpful when the user has hearing loss or is in a noisy environment. In addition, the system alerts people in the surroundings when the user stumbles over or requires assistance, and the alert, along with the system location, is sent as a phone message to registered mobile phones of family members and caregivers. In addition, the registered phones can be used to retrieve the system location whenever required and activate real-time tracking of the VIP. We tested the system prototype and verified its functionality and effectiveness. The proposed system has more features than other similar systems. We expect it to be a useful tool to improve the quality of life of VIPs. PMID:29533970
Wearable Smart System for Visually Impaired People.
Ramadhan, Ali Jasim
2018-03-13
In this paper, we present a wearable smart system to help visually impaired persons (VIPs) walk by themselves through the streets, navigate in public places, and seek assistance. The main components of the system are a microcontroller board, various sensors, cellular communication and GPS modules, and a solar panel. The system employs a set of sensors to track the path and alert the user of obstacles in front of them. The user is alerted by a sound emitted through a buzzer and by vibrations on the wrist, which is helpful when the user has hearing loss or is in a noisy environment. In addition, the system alerts people in the surroundings when the user stumbles over or requires assistance, and the alert, along with the system location, is sent as a phone message to registered mobile phones of family members and caregivers. In addition, the registered phones can be used to retrieve the system location whenever required and activate real-time tracking of the VIP. We tested the system prototype and verified its functionality and effectiveness. The proposed system has more features than other similar systems. We expect it to be a useful tool to improve the quality of life of VIPs.
NASA Technical Reports Server (NTRS)
Pritchett, Amy R.; Hansman, R. John
1996-01-01
An experimental flight simulator study was conducted to examine the mental alerting logic and thresholds used by subjects to issue an alert and execute an avoidance maneuver. Subjects flew a series of autopilot landing approaches with traffic on a closely-spaced parallel approach; during some runs, the traffic would deviate towards the subject and the subject was to indicate the point when they recognized the potential traffic conflict, and then indicate a direction of flight for an avoidance maneuver. A variety of subjects, including graduate students, general aviation pilots and airline pilots, were tested. Five traffic displays were evaluated, with a moving map TCAS-type traffic display as a baseline. A side-task created both high and low workload situations. Subjects appeared to use the lateral deviation of the intruder aircraft from its approach path as the criteria for an alert regardless of the display available. However, with displays showing heading and/or trend information, their alerting thresholds were significantly lowered. This type of range-only schema still resulted in many near misses, as a high convergence rate was often established by the time of the subject's alert. Therefore, the properties of the intruder's trajectory had the greatest effect on the resultant near miss rate; no display system reliably caused alerts timely enough for certain collision avoidance. Subjects' performance dropped significantly on a side-task while they analyzed the need for an alert, showing alert generation can be a high workload situation at critical times. No variation was found between subjects with and with out piloting experience. These results suggest the design of automatic alerting systems should take into account the range-type alerting schema used by the human, such that the rationale for the automatic alert should be obvious to, and trusted by, the operator. Although careful display design may help generate pilot/automation trust, issues such as user non-conformance to automatically generated commands can remain a possibility.
Real Time Alert System: A Disease Management System Leveraging Health Information Exchange
Anand, Vibha; Sheley, Meena E.; Xu, Shawn; Downs, Stephen M.
2012-01-01
Background Rates of preventive and disease management services can be improved by providing automated alerts and reminders to primary care providers (PCPs) using of health information technology (HIT) tools. Methods: Using Adaptive Turnaround Documents (ATAD), an existing Health Information Exchange (HIE) infrastructure and office fax machines, we developed a Real Time Alert (RTA) system. RTA is a computerized decision support system (CDSS) that is able to deliver alerts to PCPs statewide for recommended services around the time of the patient visit. RTA is also able to capture structured clinical data from providers using existing fax technology. In this study, we evaluate RTA’s performance for alerting PCPs when their patients with asthma have an emergency room visit anywhere in the state. Results: Our results show that RTA was successfully able to deliver “just in time” patient-relevant alerts to PCPs across the state. Furthermore, of those ATADs faxed back and automatically interpreted by the RTA system, 35% reported finding the provided information helpful. The PCPs who reported finding information helpful also reported making a phone call, sending a letter or seeing the patient for follow up care. Conclusions: We have successfully demonstrated the feasibility of electronically exchanging important patient related information with the PCPs statewide. This is despite a lack of a link with their electronic health records. We have shown that using our ATAD technology, a PCP can be notified quickly of an important event such as a patient’s asthma related emergency room admission so further follow up can happen in near real time. PMID:23569648
47 CFR 10.210 - CMAS participation election procedures.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 47 Telecommunication 1 2010-10-01 2010-10-01 false CMAS participation election procedures. 10.210 Section 10.210 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM Election to Participate in Commercial Mobile Alert System § 10.210 CMAS participation election procedures...
Intrusion Detection System Visualization of Network Alerts
2010-07-01
Intrusion Detection System Visualization of Network Alerts Dolores M. Zage and Wayne M. Zage Ball State University Final Report July 2010...contracts. Staff Wayne Zage, Director of the S2ERC and Professor, Department of Computer Science, Ball State University Dolores Zage, Research
Dormann, H; Criegee-Rieck, M; Neubert, A; Egger, T; Levy, M; Hahn, E G; Brune, K
2004-02-01
To investigate the effectiveness of a computer monitoring system that detects adverse drug reactions (ADRs) by laboratory signals in gastroenterology. A prospective, 6-month, pharmaco-epidemiological survey was carried out on a gastroenterological ward at the University Hospital Erlangen-Nuremberg. Two methods were used to identify ADRs. (i) All charts were reviewed daily by physicians and clinical pharmacists. (ii) A computer monitoring system generated a daily list of automatic laboratory signals and alerts of ADRs, including patient data and dates of events. One hundred and nine ADRs were detected in 474 admissions (377 patients). The computer monitoring system generated 4454 automatic laboratory signals from 39 819 laboratory parameters tested, and issued 2328 alerts, 914 (39%) of which were associated with ADRs; 574 (25%) were associated with ADR-positive admissions. Of all the alerts generated, signals of hepatotoxicity (1255), followed by coagulation disorders (407) and haematological toxicity (207), were prevalent. Correspondingly, the prevailing ADRs were concerned with the metabolic and hepato-gastrointestinal system (61). The sensitivity was 91%: 69 of 76 ADR-positive patients were indicated by an alert. The specificity of alerts was increased from 23% to 76% after implementation of an automatic laboratory signal trend monitoring algorithm. This study shows that a computer monitoring system is a useful tool for the systematic and automated detection of ADRs in gastroenterological patients.
Aircraft Alerting Systems Standardization Study. Phase IV. Accident Implications on Systems Design.
1982-06-01
computing and processing to assimilate and process status informa- 5 tion using...provided with capabilities in computing and processing , sensing, interfacing, and controlling and displaying. 17 o Computing and Processing - Algorithms...alerting system to perform a flight status monitor function would require additional sensinq, computing and processing , interfacing, and controlling
47 CFR 80.1115 - Transmission of a distress alert by a station not itself in distress.
Code of Federal Regulations, 2010 CFR
2010-10-01
... Safety System (GMDSS) Operating Procedures for Distress and Safety Communications § 80.1115 Transmission of a distress alert by a station not itself in distress. (a) A station in the mobile or mobile-satellite service which learns that a mobile unit is in distress must initiate and transmit a distress alert...
47 CFR 80.1115 - Transmission of a distress alert by a station not itself in distress.
Code of Federal Regulations, 2011 CFR
2011-10-01
... Safety System (GMDSS) Operating Procedures for Distress and Safety Communications § 80.1115 Transmission of a distress alert by a station not itself in distress. (a) A station in the mobile or mobile-satellite service which learns that a mobile unit is in distress must initiate and transmit a distress alert...
FT4 Data Analysis Summary (SSI-ARC)
NASA Technical Reports Server (NTRS)
Isaacson, Douglas R.; Gong, Chester; Reardon, Scott Edward; Santiago, Confesor
2016-01-01
Standards for Unmanned Aircraft System (UAS) Detect-and-Avoid (DAA) systems are currently being developed under the auspices of the RTCA Special Committee 228 (SC-228). To support the development of these standards, a series of flight tests has been conducted at NASAs Armstrong Flight Research Center (NASA-AFRC). The fourth in this series of flight test activities (Flight Test 4, or simply FT4) was conducted during the Spring and Summer of 2016. FT4 supported the objectives of numerous organizations working toward UAS DAA Minimum Operational Performance Standards (MOPS) and UAS DAA Radar MOPS. The summary provided herein is limited to the objectives, analysis and conclusions of the NASA Ames Research Center (NASA-ARC) SSI team toward the refinement of UAS DAA MOPS. This document provides a high-level overview of FT4 and the SSI-ARC objectives, a summary of the data analysis methodology and recommendations for UAS DAA MOPS refinements based on the data analysis results. A total of 72 encounters were flown to support SSI-ARC objectives. Test results were generally consistent with acceptable UAS DAA system performance and will be considered in broader SC-228 requirements validation efforts. Observed alert lead times indicated acceptable UAS DAA alerting performance. Effective interoperability between the UAS DAA system and the Traffic Alert and Collision Avoidance System (TCAS) was observed with one notable exception: TCAS Resolutions Advisories (RA) were observed in the absence of any DAA alert on two occasions, indicating the need for alert parameter refinement. Findings further indicated the need for continued work in the areas of DAA Well Clear Recovery logic and alert stability for Mode-C-only intruders. Finally, results demonstrated a high level of compliance with a set of evaluation criteria designed to provide anecdotal evidence of acceptable UAS DAA system performance.
An Approach for Representing Sensor Data to Validate Alerts in Ambient Assisted Living
Muñoz, Andrés; Serrano, Emilio; Villa, Ana; Valdés, Mercedes; Botía, Juan A.
2012-01-01
The mainstream of research in Ambient Assisted Living (AAL) is devoted to developing intelligent systems for processing the data collected through artificial sensing. Besides, there are other elements that must be considered to foster the adoption of AAL solutions in real environments. In this paper we focus on the problem of designing interfaces among caregivers and AAL systems. We present an alert management tool that supports carers in their task of validating alarms raised by the system. It generates text-based explanations—obtained through an argumentation process—of the causes leading to alarm activation along with graphical sensor information and 3D models, thus offering complementary types of information. Moreover, a guideline to use the tool when validating alerts is also provided. Finally, the functionality of the proposed tool is demonstrated through two real cases of alert. PMID:22778642
Epstein, Richard H; Dexter, Franklin
2012-10-01
Hypoxemia (oxygen saturation <90%) lasting 2 or more minutes occurs in 6.8% of adult patients undergoing noncardiac anesthesia in operating room settings. Alarm management functionality can be added to decision support systems (DSS) to send text alerts about vital signs outside specified thresholds, using data in anesthesia information management systems. We considered enhancing our DSS to send hypoxemia alerts to the text pagers of supervising anesthesiologists. As part of a voluntary application for an investigative device exemption from our IRB to implement such functionality, we evaluated the maximum potential utility of such an alert system. Pulse oximetry values (Spo(2)) were extracted from our anesthesia information management systems for all cases performed in our main operating rooms and ambulatory surgical center between September 1, 2011, and February 4, 2012 (n = 16,870). Hypoxemic episodes (Spo(2) < 90%) were characterized as either (a) lasting one or more minutes or (b) lasting 2 or more minutes. A single simulated "alert" was modeled as having been sent at the timestamp of the first (a) or the second (b) hypoxemic value. The hypoxemic episode was considered resolved at 1, 3, or 5 minutes after the time of the alert if the Spo(2) value was no longer below the 90% threshold. Two-sided 99% conservative confidence limits were calculated for the percentage of unresolved alerts at the 3 evaluation intervals and compared with 70%, the lower limit of an acceptable true alarm rate for clinical utility. There was at least 1 hypoxemic episode lasting 1 minute or longer in 23% of cases, and at least 1 episode lasting 2 minutes or longer in 8% of cases. Only 7% (99% confidence interval [CI] 6% to 8%) of the 1-minute hypoxemic episodes were unresolved after 3 minutes, and only 8% (99% CI 6%to 9%) of 2-minute episodes after 5 minutes (both P < 10(-6) in comparison with 70% minimum reliability rate). Low utility should be expected for a DSS sending hypoxemia alerts to supervising anesthesiologists, because nearly all hypoxemic episodes will have been resolved before arrival of the anesthesiologist in the operating room. These results suggest that the principal research focus should be on developing more sophisticated alerts and processes within rooms for the anesthesia care provider to initiate treatment promptly, to interpret or correct artifacts, and to make it easier to call for assistance via a rapid communication system.
Follow-up Observations of SDSS and CRTS Candidate Cataclysmic Variables II
NASA Astrophysics Data System (ADS)
Szkody, Paula; Everett, Mark E.; Dai, Zhibin; Serna-Grey, Donald
2018-01-01
Spectra of 38 candidate or known cataclysmic variables are presented. Most are candidate dwarf novae or systems containing possible highly magnetic white dwarfs, while a few (KR Aur, LS Peg, V380 Oph, and V694 Mon) are previously known objects caught in unusual states. Individual spectra are used to confirm a dwarf nova nature or other classification while radial velocities of 15 systems provide orbital periods and velocity amplitudes that aid in determining the nature of the objects. Our results substantiate a polar nature for four objects, find an eclipsing SW Sex star below the period gap, another as a likely intermediate polar, as well as two dwarf novae with periods in the middle of the gap. Based on observations obtained with the Apache Point Observatory (APO) 3.5 m telescope, which is owned and operated by the Astrophysical Research Consortium (ARC).
Copple, Susan S.; Jaskowski, Troy D.; Giles, Rashelle; Hill, Harry R.
2014-01-01
Objective. To evaluate NOVA View with focus on reading archived images versus microscope based manual interpretation of ANA HEp-2 slides by an experienced, certified medical technologist. Methods. 369 well defined sera from: 44 rheumatoid arthritis, 50 systemic lupus erythematosus, 35 scleroderma, 19 Sjögren's syndrome, and 10 polymyositis patients as well as 99 healthy controls were examined. In addition, 12 defined sera from the Centers for Disease Control and 100 random patient sera sent to ARUP Laboratories for ANA HEp-2 IIF testing were included. Samples were read using the archived images on NOVA View and compared to results obtained from manual reading. Results. At a 1 : 40/1 : 80 dilution the resulting comparison demonstrated 94.8%/92.9% positive, 97.4%/97.4% negative, and 96.5%/96.2% total agreements between manual IIF and NOVA View archived images. Agreement of identifiable patterns between methods was 97%, with PCNA and mixed patterns undetermined. Conclusion. Excellent agreements were obtained between reading archived images on NOVA View and manually on a fluorescent microscope. In addition, workflow benefits were observed which need to be analyzed in future studies. PMID:24741573
Regulatory alerts for dietary supplements in Canada and the United States, 2005-13.
Abe, Andrew M; Hein, Darren J; Gregory, Philip J
2015-06-01
Dietary supplement regulatory alerts published by the Food and Drug Administration (FDA) and Health Canada were evaluated and characterized. FDA MedWatch and Health Canada websites were reviewed to identify regulatory alerts regarding dietary supplements from January 1, 2005, through December 31, 2013. Alerts were analyzed to identify product characteristics that may be predictive of product quality issues and potential patient harm. A total of 1560 dietary supplement-related regulatory alerts were identified. Of those, 1287 (83%) were identified through Health Canada, and 273 (18%) were identified through FDA MedWatch. The country of origin of dietary supplements associated with regulatory alerts was not provided in most regulatory alerts; however, when their origin was provided, the United States was the most common. Dietary supplements intended for sexual enhancement were the subject of 33% of all regulatory alerts identified. Products purchased online were the most likely to be associated with a regulatory alert. Dietary supplements intended for sexual enhancement, weight loss, and bodybuilding or athletic performance appeared to pose the greatest risk for patient harm due to product contamination with a pharmaceutical such as a phosphodiesterase-5 inhibitor or sibutramine. Analysis of Canadian and U.S. regulatory alerts concerning dietary supplements revealed that more than 80% of the composite alerts were issued by Health Canada. The most common intended uses of supplements for which alerts were issued were sexual enhancement, weight loss, and bodybuilding or athletic performance. The most common reason for alerts was the presence of a pharmaceutical contaminant. Copyright © 2015 by the American Society of Health-System Pharmacists, Inc. All rights reserved.
47 CFR 10.270 - Subscribers' right to terminate subscription.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 47 Telecommunication 1 2010-10-01 2010-10-01 false Subscribers' right to terminate subscription. 10.270 Section 10.270 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM Election to Participate in Commercial Mobile Alert System § 10.270 Subscribers' right to...
47 CFR 10.260 - Timing of subscriber notification.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 47 Telecommunication 1 2010-10-01 2010-10-01 false Timing of subscriber notification. 10.260 Section 10.260 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM Election to Participate in Commercial Mobile Alert System § 10.260 Timing of subscriber notification. A CMS...
Carricajo, A.; Fonsale, N.; Vautrin, A. C.; Aubert, G.
2001-01-01
A total of 52 mycobacterial isolates were recovered from 1,197 clinical specimens decontaminated by a sodium dodecyl (lauryl) sulfate (SDS)-NaOH protocol. Of these, 94% were recovered with the BacT/Alert 3D system (Organon Teknika, Durham, N.C.) and 79% were recovered on Löwenstein-Jensen (LJ) medium. Mean times to detection of organisms of the Mycobacterium tuberculosis complex (n = 47) were 22.8 days with LJ medium and 16.2 days with the system. The BacT/Alert 3D system is a rapid and efficient detection system which can be used with an SDS-NaOH decontamination procedure. PMID:11574623
ElarmS Earthquake Early Warning System 2016 Performance and New Research
NASA Astrophysics Data System (ADS)
Chung, A. I.; Allen, R. M.; Hellweg, M.; Henson, I. H.; Neuhauser, D. S.
2016-12-01
The ElarmS earthquake early warning system has been detecting earthquakes throughout California since 2007. It is one of the algorithms that contributes to the West Coast ShakeAlert, a prototype earthquake early warning system being developed for the US West Coast. ElarmS is also running in the Pacific Northwest, and in Israel, Chile, Turkey, and Peru in test mode. We summarize the performance of the ElarmS system over the past year and review some of the more problematic events that the system has encountered. During the first half of 2016 (2016-01-01 through 2016-07-21), ElarmS successfully alerted on all events with ANSS catalog magnitudes M>3 in the Los Angeles area. The mean alert time for these 9 events was just 4.84 seconds. In the San Francisco Bay Area, ElarmS detected 26 events with ANSS catalog magnitudes M>3. The alert times for these events is 9.12 seconds. The alert times are longer in the Bay Area than in the Los Angeles area due to the sparser network of stations in the Bay Area. 7 Bay Area events were not detected by ElarmS. These events occurred in areas where there is less dense station coverage. In addition, ElarmS sent alerts for 13 of the 16 moderately-sized (ANSS catalog magnitudes M>4) events that occurred throughout the state of California. One of those missed events was a M4.5 that occurred far offshore in the northernmost part of the state. The other two missed events occurred inland in regions with sparse station coverage. Over the past year, we have worked towards the implementation of a new filterbank teleseismic filter algorithm, which we will discuss. Other than teleseismic events, a significant cause of false alerts and severely mislocated events is spurious triggers being associated with triggers from a real earthquake. Here, we address new approaches to filtering out problematic triggers.
Peyser, Thomas A; Nakamura, Katherine; Price, David; Bohnett, Lucas C; Hirsch, Irl B; Balo, Andrew
2015-08-01
Accuracy of continuous glucose monitoring (CGM) devices in hypoglycemia has been a widely reported shortcoming of this technology. We report the accuracy in hypoglycemia of a new version of the Dexcom (San Diego, CA) G4 Platinum CGM system (software 505) and present results regarding the optimum setting of CGM hypoglycemic alerts. CGM values were compared with YSI analyzer (YSI Life Sciences, Yellow Springs, OH) measurements every 15 min. We reviewed the accuracy of the CGM system in the hypoglycemic range using standard metrics. We analyzed the time required for the CGM system to detect biochemical hypoglycemia (70 mg/dL) compared with the YSI with alert settings at 70 mg/dL and 80 mg/dL. We also analyzed the time between the YSI value crossing 55 mg/dL, defined as the threshold for cognitive impairment due to hypoglycemia, and when the CGM system alerted for hypoglycemia. The mean absolute difference for a glucose level of less than 70 mg/dL was 6 mg/dL. Ninety-six percent of CGM values were within 20 mg/dL of the YSI values between 40 and 80 mg/dL. When the CGM hypoglycemic alert was set at 80 mg/dL, the device provided an alert for biochemical hypoglycemia within 10 min in 95% of instances and at least a 10-min advance warning before the cognitive impairment threshold in 91% of instances in the study. Use of an 80 mg/dL threshold setting for hypoglycemic alerts on the G4 Platinum (software 505) may provide patients with timely warning of hypoglycemia before the onset of cognitive impairment, enabling them to treat themselves for hypoglycemia with fast-acting carbohydrates and prevent neuroglycopenia associated with very low glucose levels.
Quality-improvement analytics for intravenous infusion pumps.
Skledar, Susan J; Niccolai, Cynthia S; Schilling, Dennis; Costello, Susan; Mininni, Nicolette; Ervin, Kelly; Urban, Alana
2013-04-15
The implementation of a smart-pump continuous quality-improvement (CQI) program across a large health system is described, with an emphasis on key metrics for outcomes analyses and program refinement. Three years ago, the University of Pittsburgh Medical Center health system launched a CQI initiative to help ensure the safe use of 6000 smart pumps in its 14 inpatient facilities. A centralized team led by pharmacists is responsible for the retrieval and interpretation of smart-pump data, which is continuously transmitted to a main server. CQI findings are regularly posted on the health system's interdisciplinary intranet. Monitored metrics include rates of compliance with preprogrammed infusion limits, the top 20 drugs involved in alerts, drugs associated with alert-override rates of ≥90%, numbers of alerts by infusion type, nurse responses to alerts, and alert rate per drug library update. Based on the collected CQI data and site-specific requests, four systemwide updates of the smart-pump drug library were performed during the first 18 months of the program, reducing "nuisance alerts" by about 10% per update cycle and enabling targeted interventions to reduce rapid-infusion errors, other adverse drug events (ADEs), and pump-programming workarounds. Over one 12-month period, bedside alerts prompted nurses to reprogram or cancel continuous infusions an average of 400 times per month, potentially averting i.v. medication ADEs. A smart-pump CQI program is an effective tool for enhancing the safety of i.v. medication administration. The ongoing refinement of the drug library through the development and implementation of key interventions promotes the growth and sustainability of the smart-pump initiative systemwide.
Feature-based alert correlation in security systems using self organizing maps
NASA Astrophysics Data System (ADS)
Kumar, Munesh; Siddique, Shoaib; Noor, Humera
2009-04-01
The security of the networks has been an important concern for any organization. This is especially important for the defense sector as to get unauthorized access to the sensitive information of an organization has been the prime desire for cyber criminals. Many network security techniques like Firewall, VPN Concentrator etc. are deployed at the perimeter of network to deal with attack(s) that occur(s) from exterior of network. But any vulnerability that causes to penetrate the network's perimeter of defense, can exploit the entire network. To deal with such vulnerabilities a system has been evolved with the purpose of generating an alert for any malicious activity triggered against the network and its resources, termed as Intrusion Detection System (IDS). The traditional IDS have still some deficiencies like generating large number of alerts, containing both true and false one etc. By automatically classifying (correlating) various alerts, the high-level analysis of the security status of network can be identified and the job of network security administrator becomes much easier. In this paper we propose to utilize Self Organizing Maps (SOM); an Artificial Neural Network for correlating large amount of logged intrusion alerts based on generic features such as Source/Destination IP Addresses, Port No, Signature ID etc. The different ways in which alerts can be correlated by Artificial Intelligence techniques are also discussed. . We've shown that the strategy described in the paper improves the efficiency of IDS by better correlating the alerts, leading to reduced false positives and increased competence of network administrator.
Conditional Outlier Detection for Clinical Alerting
Hauskrecht, Milos; Valko, Michal; Batal, Iyad; Clermont, Gilles; Visweswaran, Shyam; Cooper, Gregory F.
2010-01-01
We develop and evaluate a data-driven approach for detecting unusual (anomalous) patient-management actions using past patient cases stored in an electronic health record (EHR) system. Our hypothesis is that patient-management actions that are unusual with respect to past patients may be due to a potential error and that it is worthwhile to raise an alert if such a condition is encountered. We evaluate this hypothesis using data obtained from the electronic health records of 4,486 post-cardiac surgical patients. We base the evaluation on the opinions of a panel of experts. The results support that anomaly-based alerting can have reasonably low false alert rates and that stronger anomalies are correlated with higher alert rates. PMID:21346986
Conditional outlier detection for clinical alerting.
Hauskrecht, Milos; Valko, Michal; Batal, Iyad; Clermont, Gilles; Visweswaran, Shyam; Cooper, Gregory F
2010-11-13
We develop and evaluate a data-driven approach for detecting unusual (anomalous) patient-management actions using past patient cases stored in an electronic health record (EHR) system. Our hypothesis is that patient-management actions that are unusual with respect to past patients may be due to a potential error and that it is worthwhile to raise an alert if such a condition is encountered. We evaluate this hypothesis using data obtained from the electronic health records of 4,486 post-cardiac surgical patients. We base the evaluation on the opinions of a panel of experts. The results support that anomaly-based alerting can have reasonably low false alert rates and that stronger anomalies are correlated with higher alert rates.
ERIC Educational Resources Information Center
2001
This report provides the framework for response to Nova Scotia's agreement with the government of Canada to invest in an early childhood development (ECD) strategy. The report begins with a list of guiding principles for child and family services. The major challenge for the ECD strategy is to identify the key areas of investment that will create…
ERIC Educational Resources Information Center
Wootten, Marian; And Others
Separate formal evaluations were conducted of the following alternative schools in the Seattle Public Schools system: Nova, Orca, Summit K-12, Alternative School 1 (AS1), Alternative Elementary School II (AES II), and Alternative Elementary School III (AES III). These six documents, combined here as one item, describe the distinctive…
Shara, Michael M.; Doyle, Trisha F.; Lauer, Tod R.; ...
2016-11-08
The Hubble Space Telescope has imaged the central part of M87 over a 10 week span, leading to the discovery of 32 classical novae (CNe) and nine fainter, likely very slow, and/or symbiotic novae. In this first paper of a series, we present the M87 nova finder charts, and the light and color curves of the novae. We demonstrate that the rise and decline times, and the colors of M87 novae are uncorrelated with each other and with position in the galaxy. The spatial distribution of the M87 novae follows the light of the galaxy, suggesting that novae accreted by M87 during cannibalistic episodes are well-mixed. Conservatively using only the 32 brightest CNe we derive a nova rate for M87:more » $${363}_{-45}^{+33}$$ novae yr –1. We also derive the luminosity-specific classical nova rate for this galaxy, which is $${7.88}_{-2.6}^{+2.3}\\,{\\mathrm{yr}}^{-1}/{10}^{10}\\,{L}_{\\odot }{,}_{K}$$. Both rates are 3–4 times higher than those reported for M87 in the past, and similarly higher than those reported for all other galaxies. As a result, we suggest that most previous ground-based surveys for novae in external galaxies, including M87, miss most faint, fast novae, and almost all slow novae near the centers of galaxies.« less
Kearney, Peter; Li, Wen-Chin; Yu, Chung-San; Braithwaite, Graham
2018-06-26
This research investigated controller' situation awareness by comparing COOPANS's acoustic alerts with newly designed semantic alerts. The results demonstrate that ATCOs' visual scan patterns had significant differences between acoustic and semantic designs. ATCOs established different eye movement patterns on fixations number, fixation duration and saccade velocity. Effective decision support systems require human-centred design with effective stimuli to direct ATCO's attention to critical events. It is necessary to provide ATCOs with specific alerting information to reflect the nature of of the critical situation in order to minimize the side-effects of startle and inattentional deafness. Consequently, the design of a semantic alert can significantly reduce ATCOs' response time, therefore providing valuable extra time in a time-limited situation to formulate and execute resolution strategies in critical air safety events. The findings of this research indicate that the context-specified design of semantic alerts could improve ATCO's situational awareness and significantly reduce response time in the event of Short Term Conflict Alert activation which alerts to two aircraft having less than the required lateral or vertical separation.
NASA Technical Reports Server (NTRS)
Fern, Lisa
2017-01-01
The Phase 1 DAA Minimum Operational Performance Standards (MOPS) provided requirements for two classes of DAA equipment: equipment Class 1 contains the basic DAA equipment required to assist a pilot in remaining well clear, while equipment Class 2 integrates the Traffic Alert and Collision Avoidance (TCAS) II system. Thus, the Class 1 system provides RWC functionality only, while the Class 2 system is intended to provide both RWC and Collision Avoidance (CA) functionality, in compliance with the Minimum Aviation System Performance (MASPS) for the Interoperability of Airborne Collision Avoidance Systems. The FAAs TCAS Program Office is currently developing Airborne Collision Avoidance System X (ACAS X) to support the objectives of the Federal Aviation Administrations (FAA) Next Generation Air Transportation System Program (NextGen). ACAS X has a suite of variants with a common underlying design that are intended to be optimized for their intended airframes and operations. ACAS Xu being is designed for UAS and allows for new surveillance technologies and tailored logic for platforms with different performance characteristics. In addition to Collision Avoidance (CA) alerting and guidance, ACAS Xu is being tuned to provide RWC alerting and guidance in compliance with the SC 228 DAA MOPS. With a single logic performing both RWC and CA functions, ACAS Xu will provide industry with an integrated DAA solution that addresses many of the interoperability shortcomings of Phase I systems. While the MOPS for ACAS Xu will specify an integrated DAA system, it will need to show compliance with the RWC alerting thresholds and alerting requirements defined in the DAA Phase 2 MOPS. Further, some functional components of the ACAS Xu system such as the remote pilots displayed guidance might be mostly references to the corresponding requirements in the DAA MOPS. To provide a seamless, integrated, RWC-CA system to assist the pilot in remaining well clear and avoiding collisions, several issues need to be addressed within the Phase 2 SC-228 DAA efforts. Interoperability of the RWC and CA alerting and guidance, and ensuring pilot comprehension, compliance and performance, will be a primary research area.
78 FR 44931 - Privacy Act of 1974; System of Records
Federal Register 2010, 2011, 2012, 2013, 2014
2013-07-25
... disseminate emergency alerts and notification information to DLA installation personnel. DATES: This proposed... effectively disseminate emergency alerts and notification information to DLA installation personnel. Routine...
The Simplified Aircraft-Based Paired Approach With the ALAS Alerting Algorithm
NASA Technical Reports Server (NTRS)
Perry, Raleigh B.; Madden, Michael M.; Torres-Pomales, Wilfredo; Butler, Ricky W.
2013-01-01
This paper presents the results of an investigation of a proposed concept for closely spaced parallel runways called the Simplified Aircraft-based Paired Approach (SAPA). This procedure depends upon a new alerting algorithm called the Adjacent Landing Alerting System (ALAS). This study used both low fidelity and high fidelity simulations to validate the SAPA procedure and test the performance of the new alerting algorithm. The low fidelity simulation enabled a determination of minimum approach distance for the worst case over millions of scenarios. The high fidelity simulation enabled an accurate determination of timings and minimum approach distance in the presence of realistic trajectories, communication latencies, and total system error for 108 test cases. The SAPA procedure and the ALAS alerting algorithm were applied to the 750-ft parallel spacing (e.g., SFO 28L/28R) approach problem. With the SAPA procedure as defined in this paper, this study concludes that a 750-ft application does not appear to be feasible, but preliminary results for 1000-ft parallel runways look promising.
Changes in Pilot Behavior with Predictive System Status Information
NASA Technical Reports Server (NTRS)
Trujillo, Anna C.
1998-01-01
Research has shown a strong pilot preference for predictive information of aircraft system status in the flight deck. However, changes in pilot behavior associated with using this predictive information have not been ascertained. The study described here quantified these changes using three types of predictive information (none, whether a parameter was changing abnormally, and the time for a parameter to reach an alert range) and three initial time intervals until a parameter alert range was reached (ITIs) (1 minute, 5 minutes, and 15 minutes). With predictive information, subjects accomplished most of their tasks before an alert occurred. Subjects organized the time they did their tasks by locus-of-control with no predictive information and for the 1-minute ITI, and by aviatenavigate-communicate for the time for a parameter to reach an alert range and the 15-minute conditions. Overall, predictive information and the longer ITIs moved subjects to performing tasks before the alert actually occurred and had them more mission oriented as indicated by their tasks grouping of aviate-navigate-communicate.
Pilot Mental Workload with Predictive System Status Information
NASA Technical Reports Server (NTRS)
Trujillo, Anna C.
1998-01-01
Research has shown a strong pilot preference for predictive information of aircraft system status in the flight deck. However, the mental workload associated with using this predictive information has not been ascertained. The study described here attempted to measure mental workload. In this simulator experiment, three types of predictive information (none, whether a parameter was changing abnormally, and the time for a parameter to reach an alert range) and four initial times to a parameter alert range (1 minute, 5 minutes, 15 minutes, and ETA+45 minutes) were tested to determine their effects on subjects mental workload. Subjective workload ratings increased with increasing predictive information (whether a parameter was changing abnormally or the time for a parameter to reach an alert range). Subjective situation awareness decreased with more predictive information but it became greater with increasing initial times to a parameter alert range. Also, subjective focus changed depending on the type of predictive information. Lastly, skin temperature fluctuated less as the initial time to a parameter alert range increased.
The Nova-Canton Trough and the Late Cretaceous evolution of the central Pacific
NASA Astrophysics Data System (ADS)
Joseph, Devorah; Taylor, Brain; Shor, Alexander N.; Yamazaki, Toshitsugu
Free-air gravity anomalies derived from satellite altimetry data show that the major Pacific fracture zones, from the Pau to Marquesas, are co-polar about an Euler pole located at 150.5°W, 34.6°S for the period preceding chron 33 and including a large portion of the Cretaceous Normal Superchron. They also show continuity of the Clipperton Fracture Zone through the Line Islands to the Nova-Canton ridge and trough; this Canton-Clipperton trend is co-polar to the same pole. Sidescan-sonar and bathymetry data in the Nova-Canton Trough region reveal N140°E-striking abyssal hill topography south of the N70°E-striking structures of the Nova-Canton Trough and crustal fabric striking normal to the trough (N160°E) to the north. We conclude that the Nova-Canton Trough is the Middle Cretaceous extension of the Clipperton Fracture Zone. We propose that the anomalous depths (7000-8400 m) of the trough between 167°30'-168°30'W are the result of a complex plate reorganization. Conjugate magnetic anomaly lineations M1-M3 in the Phoenix lineations between the Central Pacific Fracture Zone and the Phoenix Fracture Zone and the absence of lineations younger than anomaly M3 west of the Phoenix Fracture Zone suggest that spreading may have gradually ceased along the Pacific-Phoenix system from west to east. We infer that the remaining active segment of the Pacific-Phoenix spreading system after anomaly M1 time was the easternmost section of the Phoenix lineations. At ˜M0 time, the Pacific-Phoenix spreading axis stretched from lineated bathymetric depressions lying between 180°W and the Phoenix Islands to ˜168°W and included the western deep of the Nova-Canton Trough. We hypothesize that accretion terminated on the Pacific-Phoenix spreading axis shortly after M0 time and that the absence of an M0 isochron in the region between the eastern Phoenix lineations and the Nova-Canton Trough, or along the Nova-Canton Trough itself, may be due to a decrease in spreading rate prior to termination. We concur with previous hypotheses that portions of the Phoenix plate were trapped on the Pacific plate by a ridge jump south to the nascent Manihiki Plateau; some portions were overprinted by the Aptian volcanism that formed the Manihiki Plateau and Robbie Ridge. Pacific-Farallon spreading south of the Nova-Canton Trough jumped westwards, initiating transcurrent motion along the easternmost section of the failed ˜M0 spreading axis (the western deep of the Nova-Canton Trough) which subsequently became the western end of the Clipperton (Pacific-Farallon) transform. In our reconstruction, the northeast and southeast margins of the Manihiki Plateau are rifted margins that form the western limit of Pacific-Farallon spreading between the Clipperton, Galapagos, and Marquesas fracture zones.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-05-03
...: 3060-1113. Title: Commercial Mobile Alert System (CMAS). Form No.: N/A. Type of Review: Revision of a..., Alert and Response Network (``WARN'') Act, including inter alia, a requirement that within 30 days of... the Commission indicating whether or not it intends to transmit emergency alerts as part of the...
Case-Based Multi-Sensor Intrusion Detection
NASA Astrophysics Data System (ADS)
Schwartz, Daniel G.; Long, Jidong
2009-08-01
Multi-sensor intrusion detection systems (IDSs) combine the alerts raised by individual IDSs and possibly other kinds of devices such as firewalls and antivirus software. A critical issue in building a multi-sensor IDS is alert-correlation, i.e., determining which alerts are caused by the same attack. This paper explores a novel approach to alert correlation using case-based reasoning (CBR). Each case in the CBR system's library contains a pattern of alerts raised by some known attack type, together with the identity of the attack. Then during run time, the alert streams gleaned from the sensors are compared with the patterns in the cases, and a match indicates that the attack described by that case has occurred. For this purpose the design of a fast and accurate matching algorithm is imperative. Two such algorithms were explored: (i) the well-known Hungarian algorithm, and (ii) an order-preserving matching of our own device. Tests were conducted using the DARPA Grand Challenge Problem attack simulator. These showed that the both matching algorithms are effective in detecting attacks; but the Hungarian algorithm is inefficient; whereas the order-preserving one is very efficient, in fact runs in linear time.
NASA Technical Reports Server (NTRS)
Matese, John J.; Whitmire, D. P.; Reynolds, R. T.
1989-01-01
The problem of grain nucleation during novae outbursts is a major obstacle to our understanding of dust formation in these systems. How nucleation seeds can form in the hostile post-outburst environment remains an unresolved matter. It is suggested that the material for seeding the condensation of ejecta outflow is stored in a primordial disk of icy planetesimals surrounding the system. Evidence is presented that the requisite number of nucleation seeds can be released by sublimation of the planetesimals during outbursts.
Code of Federal Regulations, 2010 CFR
2010-04-01
... hazards evaluation and classification —Language of communication and transmission of information 2. Crisis Management System —Crisis analysis and communication mechanisms —Establishment of contact points —Reporting... Considered in Developing a Two-Way Alert System 1. Documentation —Definition of a crisis/emergency and under...
Colpaert, Kirsten; Hoste, Eric A; Steurbaut, Kristof; Benoit, Dominique; Van Hoecke, Sofie; De Turck, Filip; Decruyenaere, Johan
2012-04-01
To evaluate whether a real-time electronic alert system or "AKI sniffer," which is based on the RIFLE classification criteria (Risk, Injury and Failure), would have an impact on therapeutic interventions and acute kidney injury progression. Prospective intervention study. Surgical and medical intensive care unit in a tertiary care hospital. A total of 951 patients having in total 1,079 admission episodes were admitted during the study period (prealert control group: 227, alert group: 616, and postalert control group: 236). Three study phases were compared: A 1.5-month prealert control phase in which physicians were blinded for the acute kidney injury sniffer and a 3-month intervention phase with real-time alerting of worsening RIFLE class through the Digital Enhanced Cordless Technology telephone system followed by a second 1.5-month postalert control phase. A total of 2593 acute kidney injury alerts were recorded with a balanced distribution over all study phases. Most acute kidney injury alerts were RIFLE class risk (59.8%) followed by RIFLE class injury (34.1%) and failure (6.1%). A higher percentage of patients in the alert group received therapeutic intervention within 60 mins after the acute kidney injury alert (28.7% in alert group vs. 7.9% and 10.4% in the pre- and postalert control groups, respectively, p μ .001). In the alert group, more patients received fluid therapy (23.0% vs. 4.9% and 9.2%, p μ .01), diuretics (4.2% vs. 2.6% and 0.8%, p μ .001), or vasopressors (3.9% vs. 1.1% and 0.8%, p μ .001). Furthermore, these patients had a shorter time to intervention (p μ .001). A higher proportion of patients in the alert group showed return to a baseline kidney function within 8 hrs after an acute kidney injury alert "from normal to risk" compared with patients in the control group (p = .048). The real-time alerting of every worsening RIFLE class by the acute kidney injury sniffer increased the number and timeliness of early therapeutic interventions. The borderline significant improvement of short-term renal outcome in the RIFLE class risk patients needs to be confirmed in a large multicenter trial.
NASA Technical Reports Server (NTRS)
Hack, Margherita; Selvelli, Pierluigi
1993-01-01
Recurrent novae seem to be a rather inhomogeneous group: T CrB is a binary with a M III companion; U Sco probably has a late dwarf as companion. Three are fast novae; two are slow novae. Some of them appear to have normal chemical composition; others may present He and CNO excess. Some present a mass-loss that is lower by two orders of magnitude than classical novae. However, our sample is too small for saying whether there are several classes of recurrent novae, which may be related to the various classes of classical novae, or whether the low mass-loss is a general property of the class or just a peculiarity of one member of the larger class of classical novae and recurrent novae.
ASASSN-16eg: New candidate for a long-period WZ Sge-type dwarf nova
NASA Astrophysics Data System (ADS)
Wakamatsu, Yasuyuki; Isogai, Keisuke; Kimura, Mariko; Kato, Taichi; Vanmunster, Tonny; Stone, Geoff; Tordai, Tamás; Richmond, Michael; Miller, Ian; Oksanen, Arto; Itoh, Hiroshi; Akazawa, Hidehiko; Kiyota, Seiichiro; de Miguel, Enrique; Pavlenko, Elena P.; Antonyuk, Kirill A.; Antonyuk, Oksana I.; Neustroev, Vitaly V.; Sjoberg, George; Dubovsky, Pavol A.; Pickard, Roger D.; Nogami, Daisaku
2017-12-01
We report on our photometric observations of the 2016 superoutburst of ASASSN-16eg. This object showed a WZ Sge-type superoutburst with prominent early superhumps with a period of 0.075478(8) d and a post-superoutburst rebrightening. During the superoutburst plateau, it showed ordinary superhumps with a period of 0.077880(3) d and a period derivative of 10.6(1.1) × 10-5 in stage B. The orbital period (Porb), which is almost identical with the period of the early superhumps, is exceptionally long for a WZ Sge-type dwarf nova. The mass ratio (q = M2/M1) estimated from the period of developing (stage A) superhumps is 0.166(2), which is also too large for a WZ Sge-type dwarf nova. This suggests that the 2 : 1 resonance can be reached in such high-q systems, contrary to our expectation. Such conditions are considered to be achieved if the mass-transfer rate is much lower than those in typical SU UMa-type dwarf novae that have comparable orbital periods to ASASSN-16eg, and a resultant accumulation of a large amount of matter on the disk is realized at the onset of an outburst. We examined other candidates for long-period WZ Sge-type dwarf novae for their supercycles, which are considered to reflect the mass-transfer rate, and found that V1251 Cyg and RZ Leo have longer supercycles than those of other WZ Sge-type dwarf novae. This result indicates that these long-period objects including ASASSN-16eg have a low mass-transfer rate in comparison to other WZ Sge-type dwarf novae.
Sounding the Alert: Designing an Effective Voice for Earthquake Early Warning
NASA Astrophysics Data System (ADS)
Burkett, E. R.; Given, D. D.
2015-12-01
The USGS is working with partners to develop the ShakeAlert Earthquake Early Warning (EEW) system (http://pubs.usgs.gov/fs/2014/3083/) to protect life and property along the U.S. West Coast, where the highest national seismic hazard is concentrated. EEW sends an alert that shaking from an earthquake is on its way (in seconds to tens of seconds) to allow recipients or automated systems to take appropriate actions at their location to protect themselves and/or sensitive equipment. ShakeAlert is transitioning toward a production prototype phase in which test users might begin testing applications of the technology. While a subset of uses will be automated (e.g., opening fire house doors), other applications will alert individuals by radio or cellphone notifications and require behavioral decisions to protect themselves (e.g., "Drop, Cover, Hold On"). The project needs to select and move forward with a consistent alert sound to be widely and quickly recognized as an earthquake alert. In this study we combine EEW science and capabilities with an understanding of human behavior from the social and psychological sciences to provide insight toward the design of effective sounds to help best motivate proper action by alert recipients. We present a review of existing research and literature, compiled as considerations and recommendations for alert sound characteristics optimized for EEW. We do not yet address wording of an audible message about the earthquake (e.g., intensity and timing until arrival of shaking or possible actions), although it will be a future component to accompany the sound. We consider pitch(es), loudness, rhythm, tempo, duration, and harmony. Important behavioral responses to sound to take into account include that people respond to discordant sounds with anxiety, can be calmed by harmony and softness, and are innately alerted by loud and abrupt sounds, although levels high enough to be auditory stressors can negatively impact human judgment.
DOE Office of Scientific and Technical Information (OSTI.GOV)
White, R. R.; Wren, J.; Davis, H. R.
2004-01-01
The internet has brought about great change in the astronomical community, but this interconnectivity is just starting to be exploited for use in instrumentation. Utilizing the internet for communicating between distributed astronomical systems is still in its infancy, but it already shows great potential. Here we present an example of a distributed network of telescopes that performs more efficienfiy in synchronous operation than as individual instruments. RAPid Telescopes for Optical Response (RAPTOR) is a system of telescopes at LANL that has intelligent intercommunication, combined with wide-field optics, temporal monitoring software, and deep-field follow-up capability all working in closed-loop real-time operation.more » The Telescope ALert Operations Network (TALON) is a network server that allows intercommunication of alert triggers from external and internal resources and controls the distribution of these to each of the telescopes on the network. TALON is designed to grow, allowing any number of telescopes to be linked together and communicate. Coupled with an intelligent alert client at each telescope, it can analyze and respond to each distributed TALON alert based on the telescopes needs and schedule.« less
NASA Astrophysics Data System (ADS)
Shara, Michael M.; Doyle, Trisha F.; Lauer, Tod R.; Zurek, David; Neill, J. D.; Madrid, Juan P.; Mikołajewska, Joanna; Welch, D. L.; Baltz, Edward A.
2016-11-01
The Hubble Space Telescope has imaged the central part of M87 over a 10 week span, leading to the discovery of 32 classical novae (CNe) and nine fainter, likely very slow, and/or symbiotic novae. In this first paper of a series, we present the M87 nova finder charts, and the light and color curves of the novae. We demonstrate that the rise and decline times, and the colors of M87 novae are uncorrelated with each other and with position in the galaxy. The spatial distribution of the M87 novae follows the light of the galaxy, suggesting that novae accreted by M87 during cannibalistic episodes are well-mixed. Conservatively using only the 32 brightest CNe we derive a nova rate for M87: {363}-45+33 novae yr‑1. We also derive the luminosity-specific classical nova rate for this galaxy, which is {7.88}-2.6+2.3 {yr}}-1/{10}10 {L}ȯ {,}K. Both rates are 3–4 times higher than those reported for M87 in the past, and similarly higher than those reported for all other galaxies. We suggest that most previous ground-based surveys for novae in external galaxies, including M87, miss most faint, fast novae, and almost all slow novae near the centers of galaxies. Based on observations with the NASA/ESA Hubble Space Telescope, obtained at the Space Telescope Science Institute, which is operated by AURA, Inc., under NASA contract NAS 5-26555.
NASA Astrophysics Data System (ADS)
Wald, D. J.; Jaiswal, K. S.; Marano, K.; Hearne, M.; Earle, P. S.; So, E.; Garcia, D.; Hayes, G. P.; Mathias, S.; Applegate, D.; Bausch, D.
2010-12-01
The U.S. Geological Survey (USGS) has begun publicly releasing earthquake alerts for significant earthquakes around the globe based on estimates of potential casualties and economic losses. These estimates should significantly enhance the utility of the USGS Prompt Assessment of Global Earthquakes for Response (PAGER) system that has been providing estimated ShakeMaps and computing population exposures to specific shaking intensities since 2007. Quantifying earthquake impacts and communicating loss estimates (and their uncertainties) to the public has been the culmination of several important new and evolving components of the system. First, the operational PAGER system now relies on empirically-based loss models that account for estimated shaking hazard, population exposure, and employ country-specific fatality and economic loss functions derived using analyses of losses due to recent and past earthquakes. In some countries, our empirical loss models are informed in part by PAGER’s semi-empirical and analytical loss models, and building exposure and vulnerability data sets, all of which are being developed in parallel to the empirical approach. Second, human and economic loss information is now portrayed as a supplement to existing intensity/exposure content on both PAGER summary alert (available via cell phone/email) messages and web pages. Loss calculations also include estimates of the economic impact with respect to the country’s gross domestic product. Third, in order to facilitate rapid and appropriate earthquake responses based on our probable loss estimates, in early 2010 we proposed a four-level Earthquake Impact Scale (EIS). Instead of simply issuing median estimates for losses—which can be easily misunderstood and misused—this scale provides ranges of losses from which potential responders can gauge expected overall impact from strong shaking. EIS is based on two complementary criteria: the estimated cost of damage, which is most suitable for U.S. domestic events; and estimated ranges of fatalities, which are generally more appropriate for global events, particularly in earthquake-vulnerable countries. Alert levels are characterized by alerts of green (little or no impact), yellow (regional impact and response), orange (national-scale impact and response), and red (international response). Corresponding fatality thresholds for yellow, orange, and red alert levels are 1, 100, and 1000, respectively. For damage impact, yellow, orange, and red thresholds are triggered when estimated US dollar losses reach 1 million, 100 million, and 1 billion+ levels, respectively. Finally, alerting protocols now explicitly support EIS-based alerts. Critical users can receive PAGER alerts i) based on the EIS-based alert level, in addition to or as an alternative to magnitude and population/intensity exposure-based alerts, and ii) optionally, based on user-selected regions of the world. The essence of PAGER’s impact-based alerting is that actionable loss information is now available in the immediate aftermath of significant earthquakes worldwide based on quantifiable, albeit uncertain, loss estimates provided by the USGS.
Gamma-ray emission from internal shocks in novae
NASA Astrophysics Data System (ADS)
Martin, P.; Dubus, G.; Jean, P.; Tatischeff, V.; Dosne, C.
2018-04-01
Context. Gamma-ray emission at energies ≥100 MeV has been detected from nine novae using the Fermi Large Area Telescope (LAT), and can be explained by particle acceleration at shocks in these systems. Eight out of these nine objects are classical novae in which interaction of the ejecta with a tenuous circumbinary material is not expected to generate detectable gamma-ray emission. Aim. We examine whether particle acceleration at internal shocks can account for the gamma-ray emission from these novae. The shocks result from the interaction of a fast wind radiatively-driven by nuclear burning on the white dwarf with material ejected in the initial runaway stage of the nova outburst. Methods: We present a one-dimensional model for the dynamics of a forward and reverse shock system in a nova ejecta, and for the associated time-dependent particle acceleration and high-energy gamma-ray emission. Non-thermal proton and electron spectra are calculated by solving a time-dependent transport equation for particle injection, acceleration, losses, and escape from the shock region. The predicted emission is compared to LAT observations of V407 Cyg, V1324 Sco, V959 Mon, V339 Del, V1369 Cen, and V5668 Sgr. Results: The ≥100 MeV gamma-ray emission arises predominantly from particles accelerated up to 100 GeV at the reverse shock and undergoing hadronic interactions in the dense cooling layer downstream of the shock. The emission rises within days after the onset of the wind, quickly reaches a maximum, and its subsequent decrease reflects mostly the time evolution of the wind properties. Comparison to gamma-ray data points to a typical scenario where an ejecta of mass 10-5-10-4 M⊙ expands in a homologous way with a maximum velocity of 1000-2000 km s-1, followed within a day by a wind with a velocity <2000 km s-1 and a mass-loss rate of 10-4-10-3 M⊙ yr-1 declining over a time scale of a few days. Because of the large uncertainties in the measurements, many parameters of the problem are degenerate and/or poorly constrained except for the wind velocity, the relatively low values of which result in the majority of best-fit models having gamma-ray spectra with a high-energy turnover below 10 GeV. Our typical model is able to account for the main features in the observations of the recent gamma-ray nova ASASSN-16ma. Conclusions: The internal shock model can account for the gamma-ray emission of the novae detected by Fermi LAT. Gamma-ray observations hold potential for probing the mechanism of mass ejection in novae, but should be combined to diagnostics of the thermal emission at lower energies to be more constraining.
Bentley, Claire L; Mountain, Gail A
2017-01-01
Background The increasing prevalence and associated cost of treating chronic obstructive pulmonary disease (COPD) is unsustainable. Health care organizations are focusing on ways to support self-management and prevent hospital admissions, including telehealth-monitoring services capturing physiological and health status data. This paper reports on data captured during a pilot randomized controlled trial of telehealth-supported care within a community-based service for patients discharged from hospital following an exacerbation of their COPD. Objective The aim was to undertake the first analysis of system data to determine whether telehealth monitoring can identify an exacerbation of COPD, providing clinicians with an opportunity to intervene with timely treatment and prevent hospital readmission. Methods A total of 23 participants received a telehealth-supported intervention. This paper reports on the analysis of data from a telehealth monitoring system that captured data from two sources: (1) data uploaded both manually and using Bluetooth peripheral devices by the 23 participants and (2) clinical records entered as nursing notes by the clinicians. Rules embedded in the telehealth monitoring system triggered system alerts to be reviewed by remote clinicians who determined whether clinical intervention was required. We also analyzed data on the frequency and length (bed days) of hospital admissions, frequency of hospital Accident and Emergency visits that did not lead to hospital admission, and frequency and type of community health care service contacts—other than the COPD discharge service—for all participants for the duration of the intervention and 6 months postintervention. Results Patients generated 512 alerts, 451 of which occurred during the first 42 days that all participants used the equipment. Patients generated fewer alerts over time with typically seven alerts per day within the first 10 days and four alerts per day thereafter. They also had three times more days without alerts than with alerts. Alerts were most commonly triggered by reports of being more tired, having difficulty with self-care, and blood pressure being out of range. During the 8-week intervention, and for 6-month follow-up, eight of the 23 patients were hospitalized. Hospital readmission rates (2/23, 9%) in the first 28 days of service were lower than the 20% UK norm. Conclusions It seems that the clinical team can identify exacerbations based on both an increase in alerts and the types of system-generated alerts as evidenced by their efforts to provided treatment interventions. There was some indication that telehealth monitoring potentially delayed hospitalizations until after patients had been discharged from the service. We suggest that telehealth-supported care can fulfill an important role in enabling patients with COPD to better manage their condition and remain out of hospital, but adequate resourcing and timely response to alerts is a critical factor in supporting patients to remain at home. Trial Registration International Standard Randomized Controlled Trial Number (ISRCTN): 68856013; http://www.isrctn.com/ISRCTN68856013 (Archived by WebCite at http://www.webcitation.org/6ofApNB2e) PMID:28330829
A low-cost wireless system for autonomous generation of road safety alerts
NASA Astrophysics Data System (ADS)
Banks, B.; Harms, T.; Sedigh Sarvestani, S.; Bastianini, F.
2009-03-01
This paper describes an autonomous wireless system that generates road safety alerts, in the form of SMS and email messages, and sends them to motorists subscribed to the service. Drivers who regularly traverse a particular route are the main beneficiaries of the proposed system, which is intended for sparsely populated rural areas, where information available to drivers about road safety, especially bridge conditions, is very limited. At the heart of this system is the SmartBrick, a wireless system for remote structural health monitoring that has been presented in our previous work. Sensors on the SmartBrick network regularly collect data on water level, temperature, strain, and other parameters important to safety of a bridge. This information is stored on the device, and reported to a remote server over the GSM cellular infrastructure. The system generates alerts indicating hazardous road conditions when the data exceeds thresholds that can be remotely changed. The remote server and any number of designated authorities can be notified by email, FTP, and SMS. Drivers can view road conditions and subscribe to SMS and/or email alerts through a web page. The subscription-only form of alert generation has been deliberately selected to mitigate privacy concerns. The proposed system can significantly increase the safety of travel through rural areas. Real-time availability of information to transportation authorities and law enforcement officials facilitates early or proactive reaction to road hazards. Direct notification of drivers further increases the utility of the system in increasing the safety of the traveling public.
47 CFR 10.230 - New CMS providers participation in CMAS.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 47 Telecommunication 1 2010-10-01 2010-10-01 false New CMS providers participation in CMAS. 10.230 Section 10.230 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM Election to Participate in Commercial Mobile Alert System § 10.230 New CMS providers participation in CMAS...
47 CFR 10.250 - Notification to existing subscribers of non-participation in CMAS.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 47 Telecommunication 1 2010-10-01 2010-10-01 false Notification to existing subscribers of non-participation in CMAS. 10.250 Section 10.250 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM Election to Participate in Commercial Mobile Alert System § 10.250...
47 CFR 10.220 - Withdrawal of election to participate in CMAS.
Code of Federal Regulations, 2010 CFR
2010-10-01
.... 10.220 Section 10.220 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM Election to Participate in Commercial Mobile Alert System § 10.220 Withdrawal of election... subscribers as well as the Federal Communications Commission at least sixty (60) days prior to the withdrawal...
47 CFR 10.280 - Subscribers' right to opt out of CMAS notifications.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 47 Telecommunication 1 2010-10-01 2010-10-01 false Subscribers' right to opt out of CMAS notifications. 10.280 Section 10.280 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM Election to Participate in Commercial Mobile Alert System § 10.280 Subscribers' right...
For Emergency Alerts, Some Colleges Try Sirens
ERIC Educational Resources Information Center
Young, Jeffrey R.
2008-01-01
Colleges and universities, ever more mindful of campus safety, are installing outdoor sirens. The systems can blast spoken messages or tone alerts of danger--and one of the preset messages on many of the public-address systems warns: "There is a shooter on campus. Seek shelter immediately." As college officials reviewed their…
DOT National Transportation Integrated Search
1989-01-01
The climatological study was performed to determine the impact of icing on the performance of the Low Level Winshear Alert System (LLWAS). : This report Presents the Icing Statisctical profile in the form of data tables and histograms of 106 LLWAS si...
DOT National Transportation Integrated Search
1989-09-01
The climatological study was performed to determine the impact of icing on the performance of Low Level Windshear Alert System (LLWAS). : This report presents the icing statistical profile in the form of data tables and histograms of 106 LLWAS sites....
NASA Astrophysics Data System (ADS)
Cassano, J. J.; Seefeldt, M. W.; Palo, S.; Knuth, S. L.; Bradley, A. C.; Herrman, P. D.; Kernebone, P. A.; Logan, N. J.
2015-12-01
In September 2012 five Aerosonde unmanned aircraft were used to make measurements of the atmospheric state over the Terra Nova Bay polynya, Antarctica, to explore the details of air - sea ice - ocean coupling. A total of 14 flights were completed in September 2012. Ten of the flight missions consisted of two unmanned aircraft systems (UAS) sampling the atmosphere over Terra Nova Bay on five different days, with one UAS focusing on the downwind evolution of the air mass and a second UAS flying transects roughly perpendicular to the low level winds. The data from these coordinated UAS flights provide a comprehensive three-dimensional data set of the atmospheric state (air temperature, humidity, pressure, and wind) and surface skin temperature over Terra Nova Bay. The remaining UAS flights during the September 2012 field campaign included two local flights near McMurdo Station for flight testing, a single UAS flight to Terra Nova Bay, and a single UAS flight over the Ross Ice Shelf and Ross Sea polynya. A dataset containing the atmospheric and surface data as well as operational aircraft data has been submitted to the United States Antarctic Program Data Coordination Center (USAP-DCC, http://www.usap-data.org/) for free access (http://gcmd.nasa.gov/getdif.htm?NSF-ANT10-43657, doi:10.15784/600125).
Serendipitous discovery of a dwarf Nova in the Kepler field near the G dwarf KIC 5438845
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brown, Alexander; Ayres, Thomas R.; Neff, James E.
2015-02-01
The Kepler satellite provides a unique window into stellar temporal variability by observing a wide variety of stars with multi-year, near-continuous, high precision, optical photometric time series. While most Kepler targets are faint stars with poorly known physical properties, many unexpected discoveries should result from a long photometric survey of such a large area of sky. During our Kepler Guest Observer programs that monitored late-type stars for starspot and flaring variability, we discovered a previously unknown dwarf nova that lies within a few arcseconds of the mid-G dwarf star KIC 5438845. This dwarf nova underwent nine outbursts over a 4more » year time span. The two largest outbursts lasted ∼17–18 days and show strong modulations with a 110.8 minute period and a declining amplitude during the outburst decay phase. These properties are characteristic of an SU UMa-type cataclysmic variable. By analogy with other dwarf nova light curves, we associate the 110.8 minute (1.847 hr) period with the superhump period, close to but slightly longer than the orbital period of the binary. No precursor outbursts are seen before the super-outbursts and the overall super-outburst morphology corresponds to Osaki and Meyer “Case B” outbursts, which are initiated when the outer edge of the disk reaches the tidal truncation radius. “Case B” outbursts are rare within the Kepler light curves of dwarf novae. The dwarf nova is undergoing relatively slow mass transfer, as evidenced by the long intervals between outbursts, but the mass transfer rate appears to be steady, because the smaller “normal” outbursts show a strong correlation between the integrated outburst energy and the elapsed time since the previous outburst. At super-outburst maximum the system was at V ∼ 18, but in quiescence it is fainter than V ∼ 22, which will make any detailed quiescent follow-up of this system difficult.« less
Validation of the CME Geomagnetic forecast alerts under COMESEP alert system
NASA Astrophysics Data System (ADS)
Dumbovic, Mateja; Srivastava, Nandita; Khodia, Yamini; Vršnak, Bojan; Devos, Andy; Rodriguez, Luciano
2017-04-01
An automated space weather alert system has been developed under the EU FP7 project COMESEP (COronal Mass Ejections and Solar Energetic Particles: http://comesep.aeronomy.be) to forecast solar energetic particles (SEP) and coronal mass ejection (CME) risk levels at Earth. COMESEP alert system uses automated detection tool CACTus to detect potentially threatening CMEs, drag-based model (DBM) to predict their arrival and CME geo-effectiveness tool (CGFT) to predict their geomagnetic impact. Whenever CACTus detects a halo or partial halo CME and issues an alert, DBM calculates its arrival time at Earth and CGFT calculates its geomagnetic risk level. Geomagnetic risk level is calculated based on an estimation of the CME arrival probability and its likely geo-effectiveness, as well as an estimate of the geomagnetic-storm duration. We present the evaluation of the CME risk level forecast with COMESEP alert system based on a study of geo-effective CMEs observed during 2014. The validation of the forecast tool is done by comparing the forecasts with observations. In addition, we test the success rate of the automatic forecasts (without human intervention) against the forecasts with human intervention using advanced versions of DBM and CGFT (self standing tools available at Hvar Observatory website: http://oh.geof.unizg.hr). The results implicate that the success rate of the forecast is higher with human intervention and using more advanced tools. This work has received funding from the European Commission FP7 Project COMESEP (263252). We acknowledge the support of Croatian Science Foundation under the project 6212 „Solar and Stellar Variability".
Development of a standardized, citywide process for managing smart-pump drug libraries.
Walroth, Todd A; Smallwood, Shannon; Arthur, Karen; Vance, Betsy; Washington, Alana; Staublin, Therese; Haslar, Tammy; Reddan, Jennifer G; Fuller, James
2018-06-15
Development and implementation of an interprofessional consensus-driven process for review and optimization of smart-pump drug libraries and dosing limits are described. The Indianapolis Coalition for Patient Safety (ICPS), which represents 6 Indianapolis-area health systems, identified an opportunity to reduce clinically insignificant alerts that smart infusion pumps present to end users. Through a consensus-driven process, ICPS aimed to identify best practices to implement at individual hospitals in order to establish specific action items for smart-pump drug library optimization. A work group of pharmacists, nurses, and industrial engineers met to evaluate variability within and lack of scrutiny of smart-pump drug libraries. The work group used Lean Six Sigma methodologies to generate a list of key needs and barriers to be addressed in process standardization. The group reviewed targets for smart-pump drug library optimization, including dosing limits, types of alerts reviewed, policies, and safety best practices. The work group also analyzed existing processes at each site to develop a final consensus statement outlining a model process for reviewing alerts and managing smart-pump data. Analysis of the total number of alerts per device across ICPS-affiliated health systems over a 4-year period indicated a 50% decrease (from 7.2 to 3.6 alerts per device per month) after implementation of the model by ICPS member organizations. Through implementation of a standardized, consensus-driven process for smart-pump drug library optimization, ICPS member health systems reduced clinically insignificant smart-pump alerts. Copyright © 2018 by the American Society of Health-System Pharmacists, Inc. All rights reserved.
Unusual ``Stunted'' Outbursts in Old Novae and Nova-Like Cataclysmic Variables
NASA Astrophysics Data System (ADS)
Honeycutt, R. K.; Robertson, J. W.; Turner, G. W.
1998-06-01
Outbursts averaging 0.6 mag in amplitude and 10 days in width are described in five old novae and nova-like cataclysmic variables: UU Aqr, Q Cyg, CP Lac, X Ser, and RW Sex. These stars are thought to be high mass transfer rate systems for which the accretion disk is expected to be stable against the thermal instability responsible for dwarf nova outbursts. The widths and spacings of these events are similar to those of dwarf nova eruptions, but the amplitudes are significantly smaller, or ``stunted.'' The outbursts are sometimes accompanied by dips. These dips have amplitudes that are similar to the outbursts' but have shapes that scatter significantly more than the shapes of the outbursts. The outbursts and dips sometimes occur as pairs and are sometimes isolated. We are not able at this time to determine a single common mechanism for this behavior, or even to conclude that some mechanisms are preferred. Rather, we characterize these phenomena with regard to outburst shapes and frequency of occurrence and explore a range of possible causes, including truncated disks, mass transfer modulations, and Z Camelopardalis type behavior. Arguments are assembled for and against such possible mechanisms, and key observations are suggested. It appears unlikely that accretion disk instabilities are the single common cause of these phenomena, and we are left with either a combination of accretion disk and mass transfer events or a situation in which mass transfer events are somehow responsible for all these varied behaviors.
SIMULATIONS OF THE SYMBIOTIC RECURRENT NOVA V407 CYG. I. ACCRETION AND SHOCK EVOLUTIONS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pan, Kuo-Chuan; Ricker, Paul M.; Taam, Ronald E., E-mail: kuo-chuan.pan@unibas.ch, E-mail: pmricker@illinois.edu, E-mail: r-taam@northwestern.edu, E-mail: taam@asiaa.sinica.edu.tw
2015-06-10
The shock interaction and evolution of nova ejecta with wind from a red giant (RG) star in a symbiotic binary system are investigated via three-dimensional hydrodynamics simulations. We specifically model the 2010 March outburst of the symbiotic recurrent nova V407 Cygni from its quiescent phase to its eruption phase. The circumstellar density enhancement due to wind–white-dwarf interaction is studied in detail. It is found that the density-enhancement efficiency depends on the ratio of the orbital speed to the RG wind speed. Unlike another recurrent nova, RS Ophiuchi, we do not observe a strong disk-like density enhancement, but instead observe anmore » aspherical density distribution with ∼20% higher density in the equatorial plane than at the poles. To model the 2010 outburst, we consider several physical parameters, including the RG mass-loss rate, nova eruption energy, and ejecta mass. A detailed study of the shock interaction and evolution reveals that the interaction of shocks with the RG wind generates strong Rayleigh–Taylor instabilities. In addition, the presence of the companion and circumstellar density enhancement greatly alter the shock evolution during the nova phase. Depending on the model, the ejecta speed after sweeping out most of the circumstellar medium decreases to ∼100–300 km s{sup −1}, which is consistent with the observed extended redward emission in [N ii] lines in 2011 April.« less
Electronic Health Record Alert-Related Workload as a Predictor of Burnout in Primary Care Providers.
Gregory, Megan E; Russo, Elise; Singh, Hardeep
2017-07-05
Electronic health records (EHRs) have been shown to increase physician workload. One EHR feature that contributes to increased workload is asynchronous alerts (also known as inbox notifications) related to test results, referral responses, medication refill requests, and messages from physicians and other health care professionals. This alert-related workload results in negative cognitive outcomes, but its effect on affective outcomes, such as burnout, has been understudied. To examine EHR alert-related workload (both objective and subjective) as a predictor of burnout in primary care providers (PCPs), in order to ultimately inform interventions aimed at reducing burnout due to alert workload. A cross-sectional questionnaire and focus group of 16 PCPs at a large medical center in the southern United States. Subjective, but not objective, alert workload was related to two of the three dimensions of burnout, including physical fatigue (p = 0.02) and cognitive weariness (p = 0.04), when controlling for organizational tenure. To reduce alert workload and subsequent burnout, participants indicated a desire to have protected time for alert management, fewer unnecessary alerts, and improvements to the EHR system. Burnout associated with alert workload may be in part due to subjective differences at an individual level, and not solely a function of the objective work environment. This suggests the need for both individual and organizational-level interventions to improve alert workload and subsequent burnout. Additional research should confirm these findings in larger, more representative samples.
Zachariah, Marianne; Seidling, Hanna M; Neri, Pamela M; Cresswell, Kathrin M; Duke, Jon; Bloomrosen, Meryl; Volk, Lynn A; Bates, David W
2011-01-01
Background Medication-related decision support can reduce the frequency of preventable adverse drug events. However, the design of current medication alerts often results in alert fatigue and high over-ride rates, thus reducing any potential benefits. Methods The authors previously reviewed human-factors principles for relevance to medication-related decision support alerts. In this study, instrument items were developed for assessing the appropriate implementation of these human-factors principles in drug–drug interaction (DDI) alerts. User feedback regarding nine electronic medical records was considered during the development process. Content validity, construct validity through correlation analysis, and inter-rater reliability were assessed. Results The final version of the instrument included 26 items associated with nine human-factors principles. Content validation on three systems resulted in the addition of one principle (Corrective Actions) to the instrument and the elimination of eight items. Additionally, the wording of eight items was altered. Correlation analysis suggests a direct relationship between system age and performance of DDI alerts (p=0.0016). Inter-rater reliability indicated substantial agreement between raters (κ=0.764). Conclusion The authors developed and gathered preliminary evidence for the validity of an instrument that measures the appropriate use of human-factors principles in the design and display of DDI alerts. Designers of DDI alerts may use the instrument to improve usability and increase user acceptance of medication alerts, and organizations selecting an electronic medical record may find the instrument helpful in meeting their clinicians' usability needs. PMID:21946241
The Galactic Nova Rate Revisited
NASA Astrophysics Data System (ADS)
Shafter, A. W.
2017-01-01
Despite its fundamental importance, a reliable estimate of the Galactic nova rate has remained elusive. Here, the overall Galactic nova rate is estimated by extrapolating the observed rate for novae reaching m≤slant 2 to include the entire Galaxy using a two component disk plus bulge model for the distribution of stars in the Milky Way. The present analysis improves on previous work by considering important corrections for incompleteness in the observed rate of bright novae and by employing a Monte Carlo analysis to better estimate the uncertainty in the derived nova rates. Several models are considered to account for differences in the assumed properties of bulge and disk nova populations and in the absolute magnitude distribution. The simplest models, which assume uniform properties between bulge and disk novae, predict Galactic nova rates of ˜50 to in excess of 100 per year, depending on the assumed incompleteness at bright magnitudes. Models where the disk novae are assumed to be more luminous than bulge novae are explored, and predict nova rates up to 30% lower, in the range of ˜35 to ˜75 per year. An average of the most plausible models yields a rate of {50}-23+31 yr-1, which is arguably the best estimate currently available for the nova rate in the Galaxy. Virtually all models produce rates that represent significant increases over recent estimates, and bring the Galactic nova rate into better agreement with that expected based on comparison with the latest results from extragalactic surveys.
Rapid deployable global sensing hazard alert system
Cordaro, Joseph V; Tibrea, Steven L; Shull, Davis J; Coleman, Jerry T; Shuler, James M
2015-04-28
A rapid deployable global sensing hazard alert system and associated methods of operation are provided. An exemplary system includes a central command, a wireless backhaul network, and a remote monitoring unit. The remote monitoring unit can include a positioning system configured to determine a position of the remote monitoring unit based on one or more signals received from one or more satellites located in Low Earth Orbit. The wireless backhaul network can provide bidirectional communication capability independent of cellular telecommunication networks and the Internet. An exemplary method includes instructing at least one of a plurality of remote monitoring units to provide an alert based at least in part on a location of a hazard and a plurality of positions respectively associated with the plurality of remote monitoring units.
Cutrona, Sarah L; Fouayzi, Hassan; Burns, Laura; Sadasivam, Rajani S; Mazor, Kathleen M; Gurwitz, Jerry H; Garber, Lawrence; Sundaresan, Devi; Houston, Thomas K; Field, Terry S
2017-11-01
Time-sensitive alerts are among the many types of clinical notifications delivered to physicians' secure InBaskets within commercial electronic health records (EHRs). A delayed alert review can impact patient safety and compromise care. To characterize factors associated with opening of non-interruptive time-sensitive alerts delivered into primary care provider (PCP) InBaskets. We analyzed data for 799 automated alerts. Alerts highlighted actionable medication concerns for older patients post-hospital discharge (2010-2011). These were study-generated alerts sent 3 days post-discharge to InBaskets for 75 PCPs across a multisite healthcare system, and represent a subset of all urgent InBasket notifications. Using EHR access and audit logs to track alert opening, we performed bivariate and multivariate analyses calculating associations between patient characteristics, provider characteristics, contextual factors at the time of alert delivery (number of InBasket notifications, weekday), and alert opening within 24 h. At the time of alert delivery, the PCPs had a median of 69 InBasket notifications and had received a median of 379.8 notifications (IQR 295.0, 492.0) over the prior 7 days. Of the 799 alerts, 47.1% were opened within 24 h. Patients with longer hospital stays (>4 days) were marginally more likely to have alerts opened (OR 1.48 [95% CI 1.00-2.19]). Alerts delivered to PCPs whose InBaskets had a higher number of notifications at the time of alert delivery were significantly less likely to be opened within 24 h (top quartile >157 notifications: OR 0.34 [95% CI 0.18-0.61]; reference bottom quartile ≤42). Alerts delivered on Saturdays were also less likely to be opened within 24 h (OR 0.18 [CI 0.08-0.39]). The number of total InBasket notifications and weekend delivery may impact the opening of time-sensitive EHR alerts. Further study is needed to support safe and effective approaches to care team management of InBasket notifications.
Tzeng, Huey-Ming; Hu, Hsou Mei; Yin, Chang-Yi
2011-12-01
Medicare no longer reimburses acute care hospitals for the costs of additional care required due to hospital-acquired injuries. Consequently, this study explored the effective computerized systems to inform practice for better interventions to reduce fall risk. It provided a correlation between type of computerized system and hospital-acquired injurious fall rates at acute care hospitals in California, Florida, and New York. It used multiple publicly available data sets, with the hospital as the unit of analysis. Descriptive and Pearson correlation analyses were used. The analysis included 462 hospitals. Significant correlations could be categorized into two groups: (1) meaningful computerized systems that were associated with lower injurious fall rates: the decision support systems for drug allergy alerts, drug-drug interaction alerts, and drug-laboratory interaction alerts; and (2) computerized systems that were associated with higher injurious fall rates: the decision support system for drug-drug interaction alerts and the computerized provider order entry system for radiology tests. Future research may include additional states, multiple years of data, and patient-level data to validate this study's findings. This effort may further inform policy makers and the public about effective clinical computerized systems provided to clinicians to improve their practice decisions and care outcomes.
Sethuraman, Usha; Kannikeswaran, Nirupama; Murray, Kyle P; Zidan, Marwan A; Chamberlain, James M
2015-06-01
Prescription errors occur frequently in pediatric emergency departments (PEDs).The effect of computerized physician order entry (CPOE) with electronic medication alert system (EMAS) on these is unknown. The objective was to compare prescription errors rates before and after introduction of CPOE with EMAS in a PED. The hypothesis was that CPOE with EMAS would significantly reduce the rate and severity of prescription errors in the PED. A prospective comparison of a sample of outpatient, medication prescriptions 5 months before and after CPOE with EMAS implementation (7,268 before and 7,292 after) was performed. Error types and rates, alert types and significance, and physician response were noted. Medication errors were deemed significant if there was a potential to cause life-threatening injury, failure of therapy, or an adverse drug effect. There was a significant reduction in the errors per 100 prescriptions (10.4 before vs. 7.3 after; absolute risk reduction = 3.1, 95% confidence interval [CI] = 2.2 to 4.0). Drug dosing error rates decreased from 8 to 5.4 per 100 (absolute risk reduction = 2.6, 95% CI = 1.8 to 3.4). Alerts were generated for 29.6% of prescriptions, with 45% involving drug dose range checking. The sensitivity of CPOE with EMAS in identifying errors in prescriptions was 45.1% (95% CI = 40.8% to 49.6%), and the specificity was 57% (95% CI = 55.6% to 58.5%). Prescribers modified 20% of the dosing alerts, resulting in the error not reaching the patient. Conversely, 11% of true dosing alerts for medication errors were overridden by the prescribers: 88 (11.3%) resulted in medication errors, and 684 (88.6%) were false-positive alerts. A CPOE with EMAS was associated with a decrease in overall prescription errors in our PED. Further system refinements are required to reduce the high false-positive alert rates. © 2015 by the Society for Academic Emergency Medicine.
Tora, Hammar; Bo, Hovstadius; Bodil, Lidström; Göran, Petersson; Birgit, Eiermann
2014-10-01
Background Drug related problems (DRPs) are frequent and cause suffering for patients and substantial costs for society. Multi-dose drug dispensing (MDDD) is a service by which patients receive their medication packed in bags with one unit for each dose occasion. The clinical decision support system (CDSS) electronic expert support (EES) analyses patients' prescriptions in the Swedish national e-prescription repository and provides alerts if potential DRPs are detected, i.e. drug-drug interactions, duplicate therapy, drug-disease contraindications, high dose, gender warnings, geriatric, and paediatric alerts. Objective To analyse potential DRPs in patients with MDDD, detected by means of EES. Setting A register study of all electronically stored prescriptions for patients with MDDD in Sweden (n = 180,059) March 5-June 5, 2013. Method Drug use and potential DRPs detected in the study population during the 3 month study period by EES were analysed. The potential DRPs were analysed in relation to patients' age, gender, number of drugs, and type of medication. Main outcome measure Prevalence of potential DRPs measured as EES alerts. Results The study population was on average 75.8 years of age (± 17.5, range 1-110) and had 10.0 different medications (± 4.7, range 1-53). EES alerted for potential DRPs in 76 % of the population with a mean of 2.2 alerts per patient (± 2.4, range 0-27). The older patients received a lower number of alerts compared to younger patients despite having a higher number of drugs. The most frequent alert categories were drug-drug interactions (37 % of all alerts), duplicate therapy (30 %), and geriatric warnings for high dose or inappropriate drugs (23 %). Psycholeptics, psychoanaleptics, antithrombotic agents, anti-epileptics, renin-angiotensin system agents, and analgesics represented 71 % of all drugs involved in alerts. Conclusions EES detected potential DRPs in the majority of patients with MDDD. The number of potential DRPs was associated with the number of drugs, age, gender, and type of medication. A CDSS such as EES might be a useful tool for physicians and pharmacists to assist in the important task of monitoring patients with MDDD for potential DRPs.
Pilot Non-Conformance to Alerting System Commands During Closely Spaced Parallel Approaches
NASA Technical Reports Server (NTRS)
Pritchett, Amy R.; Hansman, R. John
1997-01-01
Pilot non-conformance to alerting system commands has been noted in general and to a TCAS-like collision avoidance system in a previous experiment. This paper details two experiments studying collision avoidance during closely-spaced parallel approaches in instrument meteorological conditions (IMC), and specifically examining possible causal factors of, and design solutions to, pilot non-conformance.
Novel online monitoring and alert system for anaerobic digestion reactors.
Dong, Fang; Zhao, Quan-Bao; Li, Wen-Wei; Sheng, Guo-Ping; Zhao, Jin-Bao; Tang, Yong; Yu, Han-Qing; Kubota, Kengo; Li, Yu-You; Harada, Hideki
2011-10-15
Effective monitoring and diagnosis of anaerobic digestion processes is a great challenge for anaerobic digestion reactors, which limits their stable operation. In this work, an online monitoring and alert system for upflow anaerobic sludge blanket (UASB) reactors is developed on the basis of a set of novel evaluating indexes. The two indexes, i.e., stability index S and auxiliary index a, which incorporate both gas- and liquid-phase parameters for UASB, enable a quantitative and comprehensive evaluation of reactor status. A series of shock tests is conducted to evaluate the response of the monitoring and alert system to organic overloading, hydraulic, temperature, and toxicant shocks. The results show that this system enables an accurate and rapid monitoring and diagnosis of the reactor status, and offers reliable early warnings on the potential risks. As the core of this system, the evaluating indexes are demonstrated to be of high accuracy and sensitivity in process evaluation and good adaptability to the artificial intelligence and automated control apparatus. This online monitoring and alert system presents a valuable effort to promote the automated monitoring and control of anaerobic digestion process, and holds a high promise for application.
The agile alert system for gamma-ray transients
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bulgarelli, A.; Trifoglio, M.; Gianotti, F.
2014-01-20
In recent years, a new generation of space missions has offered great opportunities for discovery in high-energy astrophysics. In this article we focus on the scientific operations of the Gamma-Ray Imaging Detector (GRID) on board the AGILE space mission. AGILE-GRID, sensitive in the energy range of 30 MeV-30 GeV, has detected many γ-ray transients of both galactic and extragalactic origin. This work presents the AGILE innovative approach to fast γ-ray transient detection, which is a challenging task and a crucial part of the AGILE scientific program. The goals are to describe (1) the AGILE Gamma-Ray Alert System, (2) a newmore » algorithm for blind search identification of transients within a short processing time, (3) the AGILE procedure for γ-ray transient alert management, and (4) the likelihood of ratio tests that are necessary to evaluate the post-trial statistical significance of the results. Special algorithms and an optimized sequence of tasks are necessary to reach our goal. Data are automatically analyzed at every orbital downlink by an alert pipeline operating on different timescales. As proper flux thresholds are exceeded, alerts are automatically generated and sent as SMS messages to cellular telephones, via e-mail, and via push notifications from an application for smartphones and tablets. These alerts are crosschecked with the results of two pipelines, and a manual analysis is performed. Being a small scientific-class mission, AGILE is characterized by optimization of both scientific analysis and ground-segment resources. The system is capable of generating alerts within two to three hours of a data downlink, an unprecedented reaction time in γ-ray astrophysics.« less
The AGILE Alert System for Gamma-Ray Transients
NASA Astrophysics Data System (ADS)
Bulgarelli, A.; Trifoglio, M.; Gianotti, F.; Tavani, M.; Parmiggiani, N.; Fioretti, V.; Chen, A. W.; Vercellone, S.; Pittori, C.; Verrecchia, F.; Lucarelli, F.; Santolamazza, P.; Fanari, G.; Giommi, P.; Beneventano, D.; Argan, A.; Trois, A.; Scalise, E.; Longo, F.; Pellizzoni, A.; Pucella, G.; Colafrancesco, S.; Conforti, V.; Tempesta, P.; Cerone, M.; Sabatini, P.; Annoni, G.; Valentini, G.; Salotti, L.
2014-01-01
In recent years, a new generation of space missions has offered great opportunities for discovery in high-energy astrophysics. In this article we focus on the scientific operations of the Gamma-Ray Imaging Detector (GRID) on board the AGILE space mission. AGILE-GRID, sensitive in the energy range of 30 MeV-30 GeV, has detected many γ-ray transients of both galactic and extragalactic origin. This work presents the AGILE innovative approach to fast γ-ray transient detection, which is a challenging task and a crucial part of the AGILE scientific program. The goals are to describe (1) the AGILE Gamma-Ray Alert System, (2) a new algorithm for blind search identification of transients within a short processing time, (3) the AGILE procedure for γ-ray transient alert management, and (4) the likelihood of ratio tests that are necessary to evaluate the post-trial statistical significance of the results. Special algorithms and an optimized sequence of tasks are necessary to reach our goal. Data are automatically analyzed at every orbital downlink by an alert pipeline operating on different timescales. As proper flux thresholds are exceeded, alerts are automatically generated and sent as SMS messages to cellular telephones, via e-mail, and via push notifications from an application for smartphones and tablets. These alerts are crosschecked with the results of two pipelines, and a manual analysis is performed. Being a small scientific-class mission, AGILE is characterized by optimization of both scientific analysis and ground-segment resources. The system is capable of generating alerts within two to three hours of a data downlink, an unprecedented reaction time in γ-ray astrophysics.
Lyons, R A; Rodgers, S E; Thomas, S; Bailey, R; Brunt, H; Thayer, D; Bidmead, J; Evans, B A; Harold, P; Hooper, M; Snooks, H
2016-05-23
There is no evidence to date on whether an intervention alerting people to high levels of pollution is effective in reducing health service utilisation. We evaluated alert accuracy and the effect of a targeted personal air pollution alert system, airAware, on emergency hospital admissions, emergency department attendances, general practitioner contacts and prescribed medications. Quasi-experimental study describing accuracy of alerts compared with pollution triggers; and comparing relative changes in healthcare utilisation in the intervention group to those who did not sign-up. Participants were people diagnosed with asthma, chronic obstructive pulmonary disease (COPD) or coronary heart disease, resident in an industrial area of south Wales and registered patients at 1 of 4 general practices. Longitudinal anonymised record linked data were modelled for participants and non-participants, adjusting for differences between groups. During the 2-year intervention period alerts were correctly issued on 208 of 248 occasions; sensitivity was 83.9% (95% CI 78.8% to 87.9%) and specificity 99.5% (95% CI 99.3% to 99.6%). The intervention was associated with a 4-fold increase in admissions for respiratory conditions (incidence rate ratio (IRR) 3.97; 95% CI 1.59 to 9.93) and a near doubling of emergency department attendance (IRR=1.89; 95% CI 1.34 to 2.68). The intervention was associated with increased emergency admissions for respiratory conditions. While findings may be context specific, evidence from this evaluation questions the benefits of implementing near real-time personal pollution alert systems for high-risk individuals. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
NASA Technical Reports Server (NTRS)
Ford, Holland C.; Ciardullo, Robin
1988-01-01
Nova shells are characteristically prolate with equatorial bands and polar caps. Failure to account for the geometry can lead to large errors in expansion parallaxes for individual novae. When simple prescriptions are used for deriving expansion parallaxes from an ensemble of randomly oriented prolate spheroids, the average distance will be too small by factors of 10 to 15 percent. The absolute magnitudes of the novae will be underestimated and the resulting distance scale will be too small by the same factors. If observations of partially resolved nova shells select for large inclinations, the systematic error in the resulting distance scale could easily be 20 to 30 percent. Extinction by dust in the bulge of M31 may broaden and shift the intrinsic distribution of maximum nova magnitudes versus decay rates. We investigated this possibility by projecting Arp's and Rosino's novae onto a composite B - 6200A color map of M31's bulge. Thirty two of the 86 novae projected onto a smooth background with no underlying structure due to the presence of a dust cloud along the line of sight. The distribution of maximum magnitudes versus fade rates for these unreddened novae is indistinguishable from the distribution for the entire set of novae. It is concluded that novae suffer very little extinction from the filamentary and patchy distribution of dust seen in the bulge of M31. Time average B and H alpha nova luminosity functions are potentially powerful new ways to use novae as standard candles. Modern CCD observations and the photographic light curves of M31 novae found during the last 60 years were analyzed to show that these functions are power laws. Consequently, unless the eruption times for novae are known, the data cannot be used to obtain distances.
A business rules design framework for a pharmaceutical validation and alert system.
Boussadi, A; Bousquet, C; Sabatier, B; Caruba, T; Durieux, P; Degoulet, P
2011-01-01
Several alert systems have been developed to improve the patient safety aspects of clinical information systems (CIS). Most studies have focused on the evaluation of these systems, with little information provided about the methodology leading to system implementation. We propose here an 'agile' business rule design framework (BRDF) supporting both the design of alerts for the validation of drug prescriptions and the incorporation of the end user into the design process. We analyzed the unified process (UP) design life cycle and defined the activities, subactivities, actors and UML artifacts that could be used to enhance the agility of the proposed framework. We then applied the proposed framework to two different sets of data in the context of the Georges Pompidou University Hospital (HEGP) CIS. We introduced two new subactivities into UP: business rule specification and business rule instantiation activity. The pharmacist made an effective contribution to five of the eight BRDF design activities. Validation of the two new subactivities was effected in the context of drug dosage adaption to the patients' clinical and biological contexts. Pilot experiment shows that business rules modeled with BRDF and implemented as an alert system triggered an alert for 5824 of the 71,413 prescriptions considered (8.16%). A business rule design framework approach meets one of the strategic objectives for decision support design by taking into account three important criteria posing a particular challenge to system designers: 1) business processes, 2) knowledge modeling of the context of application, and 3) the agility of the various design steps.
X-ray nova and LMXB V404 Cyg in rare outburst
NASA Astrophysics Data System (ADS)
Waagen, Elizabeth O.
2015-06-01
V404 Cyg, an X-ray nova and a low mass X-ray binary (LMXB) with black hole component, is undergoing its first reported X-ray and optical outburst since 1989. Large scale, rapid variations are being reported in wavelengths from X-ray to radio by professional and amateur astronomers worldwide. Satellite and ground-based observations have been and are continuing to be made by many members of the professional community, including S. D. Barthelmy et al. (GCN Circular 17929, 15 June 2015, Swift BAT initial detection); H. Negoro et al. (ATel #7646, 17 Jun 2015); E. Kuulkers et al. (ATel #7647, 17 June 2015, Swift observations); K. Gazeas et al. (ATel #7650, 17 June 2015, optical photometry); R. M. Wagner et al. (ATel #7655, 18 June, optical spectroscopy); K. Mooley et al. (ATel #7658, 18 June, radio observations). T. Munoz-Darias et al. report P Cyg profiles were seen on 18 Jun 2015 (ATel #7659). They note that P-Cyg profiles were also observed during the 1989 outburst (Casares et al. 1991, MNRAS, 250, 712), and that V404 Cyg is so far the only black hole X-ray transient that has shown this phenomenology. Observations in all bands are requested. Filtered observations are preferred. Please use a cadence as high as possible while obtaining a suitable s/n. If spectroscopy is possible with your equipment, it is requested. Finder charts with sequence may be created using the AAVSO Variable Star Plotter (https://www.aavso.org/vsp). Observations should be submitted to the AAVSO International Database. Precise observing instructions and other details are given in the full Alert Notice.
Alsolamy, Sami; Al Salamah, Majid; Al Thagafi, Majed; Al-Dorzi, Hasan M; Marini, Abdellatif M; Aljerian, Nawfal; Al-Enezi, Farhan; Al-Hunaidi, Fatimah; Mahmoud, Ahmed M; Alamry, Ahmed; Arabi, Yaseen M
2014-12-05
Early recognition of severe sepsis and septic shock is challenging. The aim of this study was to determine the diagnostic accuracy of an electronic alert system in detecting severe sepsis or septic shock among emergency department (ED) patients. An electronic sepsis alert system was developed as a part of a quality-improvement project for severe sepsis and septic shock. The system screened all adult ED patients for a combination of systemic inflammatory response syndrome and organ dysfunction criteria (hypotension, hypoxemia or lactic acidosis). This study included all patients older than 14 years who presented to the ED of a tertiary care academic medical center from Oct. 1, 2012 to Jan. 31, 2013. As a comparator, emergency medicine physicians or the critical care physician identified the patients with severe sepsis or septic shock. In the ED, vital signs were manually entered into the hospital electronic heath record every hour in the critical care area and every two hours in other areas. We also calculated the time from the alert to the intensive care unit (ICU) referral. Of the 49,838 patients who presented to the ED, 222 (0.4%) were identified to have severe sepsis or septic shock. The electronic sepsis alert had a sensitivity of 93.18% (95% CI, 88.78% - 96.00%), specificity of 98.44 (95% CI, 98.33% - 98.55%), positive predictive value of 20.98% (95% CI, 18.50% - 23.70%) and negative predictive value of 99.97% (95% CI, 99.95% - 99.98%) for severe sepsis and septic shock. The alert preceded ICU referral by a median of 4.02 hours (Q1 - Q3: 1.25-8.55). Our study shows that electronic sepsis alert tool has high sensitivity and specificity in recognizing severe sepsis and septic shock, which may improve early recognition and management.
Doshi-Velez, Finale; Li, William; Battat, Yoni; Charrow, Ben; Curtis, Dorothy; Curthis, Dorothy; Park, Jun-geun; Hemachandra, Sachithra; Velez, Javier; Walsh, Cynthia; Fredette, Don; Reimer, Bryan; Roy, Nicholas; Teller, Seth
2012-07-01
To assess the effectiveness of a wireless network (WiFi-based) localization system (devices mounted on resident wheelchairs) in decreasing caretaker time spent searching for residents and providing alerts of residents going outdoors in a skilled nursing facility. A controlled study over two 2-month periods approved by the institutional review board. A long-term skilled nursing facility in Massachusetts specializing in multiple sclerosis previously instrumented with wireless network infrastructure. Nineteen residents and 9 staff members at the facility for the first 2-month period; 9 residents and 3 staff members at the facility for the second 2-month period. Software was installed on 4 staff computers to display the locations of residents enrolled in the study. This software was made available to enrolled staff for the second half of the first 2-month period and the entirety of the second 2-month study. In the second 2-month study, the software was modified to provide alerts if any 1 of 9 participating "high-risk"' residents went outdoors, and the accuracy of the alert system was evaluated. In the first 2-month study, 9 staff members recorded the amount of time it took them to locate participating residents (as and when needed during the course of their daily activities). In the second 2-month study, 3 staff members recorded whether outdoor-alerts correctly identified a resident leaving the building or if it was a false alarm. In both phases, participating staff members made frequent use of the system (44 searches and 215 outdoor alerts). Overall, the localization information decreased the average time needed to find residents by about two-thirds (from 311.1 seconds to 110.9 seconds). For outdoor alerts, the system had a false-alarm rate of 9.1% (under normal facility operations); systematic tests of the outdoor-alert system carried out by the authors had a false-negative, or missed-alarm, rate of 1.7%. Using timely resident location information can provide significant gains for both operational efficiency (finding residents) and enhanced resident safety (outdoor alerts). This approach may provide an inexpensive alternative for facilities that have sufficient wireless infrastructure; future work should assess its effectiveness in additional settings. Copyright © 2012 American Medical Directors Association. Published by Elsevier Inc. All rights reserved.
Shuptar, Susan L.; Milord, Philippe; Essick, Connor J.; Nevrekar, Reshma; Granovsky, Svetlana L.; Seo, Susan K.; Martin, Steven C.; Pessin, Melissa S.
2015-01-01
We implemented hospital information system (HIS) alerts to deter unnecessary test orders for ovum and parasite (O&P) exams and Clostridium difficile PCR. The HIS alerts decreased noncompliant O&P orders (orders after >72 h of hospitalization) from 49.8% to 30.9%, an overall decrease of 19%, and reduced noncompliant C. difficile PCR orders (orders <7 days after a previous positive result) from 30.6% to 19.2%, an overall decrease of 31.9%. PMID:26063860
Classical novae and recurrent novae: General properties
NASA Technical Reports Server (NTRS)
Hack, Margherita; Selvelli, Pierluigi; Duerbeck, Hilmar W.
1993-01-01
We describe the observable characteristics of classical novae and recurrent novae obtained by different techniques (photometry, spectroscopy, and imaging) in all the available spectral ranges. We consider the three stages in the life of a nova: quiescence (pre- and post-outburst), outburst, final decline and nebular phase. We describe the photometric properties during the quiescent phase. We describe the photometric properties during outburst, the classification according the rate of decline (magnitudes per day), which permits us to define very fast, fast, intermediate, slow, and very slow novae and the correlation between luminosity and speed class. We report the scanty data on the spectra of the few known prenovae and those on the spectra of old novae and those of dwarf novae and nova-like, which, however, are almost undistinguishable. We describe the typical spectra appearing from the beginning of the outburst, just before maximum, up to the nebular phase and the correlation between spectral type at maximum, expansional velocity, and speed class of the nova. We report the existing infrared observations, which permit us to explain some of the characteristics of the outburst light curve, and give evidence of the formation of a dust shell in slow and intermediate novae (with the important exception of the very slow nova HR Del 1967) and its absence or quasi-absence in fast novae. The ultraviolet and X-ray observations are described. The X ray observations of novae, mainly from the two satellites EINSTEIN and EXOSAT, are reported. Observations of the final decline and of the envelopes appearing several months after outburst are also reported.
Stacey, J.S.; Hope, J.
1975-01-01
A system is described which uses a minicomputer to control a surface ionization mass spectrometer in the peak switching mode, with the object of computing isotopic abundance ratios of elements of geologic interest. The program uses the BASIC language and is sufficiently flexible to be used for multiblock analyses of any spectrum containing from two to five peaks. In the case of strontium analyses, ratios are corrected for rubidium content and normalized for mass spectrometer fractionation. Although almost any minicomputer would be suitable, the model used was the Data General Nova 1210 with 8K memory. Assembly language driver program and interface hardware-descriptions for the Nova 1210 are included.
NASA Astrophysics Data System (ADS)
Barry, R. K.; Danchi, W. C.
2008-12-01
We review observations of nova RS Ophiuchi using long-baseline near-infrared and mid-infrared interferometry at three observatories: the Keck Interferometer in the Nulling mode (KIN), the Palomar Testbed Interferometer (PTI), and the Infrared and Optical Telescope Array (IOTA). We discuss these observations in the context of a unifying model of the system that includes an increase in density in the plane of the orbit of the two stars created by a spiral shock wave caused by the motion of the stars through the cool wind of the red giant star. We discuss how recent observations using the Spitzer Space Telescope and the VLTI support this proposed model.
Usability Flaws in Medication Alerting Systems: Impact on Usage and Work System.
Marcilly, R; Ammenwerth, E; Roehrer, E; Pelayo, S; Vasseur, F; Beuscart-Zéphir, M-C
2015-08-13
Previous research has shown that medication alerting systems face usability issues. There has been no previous attempt to systematically explore the consequences of usability flaws in such systems on users (i.e. usage problems) and work systems (i.e. negative outcomes). This paper aims at exploring and synthesizing the consequences of usability flaws in terms of usage problems and negative outcomes on the work system. A secondary analysis of 26 papers included in a prior systematic review of the usability flaws in medication alerting was performed. Usage problems and negative outcomes were extracted and sorted. Links between usability flaws, usage problems, and negative outcomes were also analyzed. Poor usability generates a large variety of consequences. It impacts the user from a cognitive, behavioral, emotional, and attitudinal perspective. Ultimately, usability flaws have negative consequences on the workflow, the effectiveness of the technology, the medication management process, and, more importantly, patient safety. Only few complete pathways leading from usability flaws to negative outcomes were identified. Usability flaws in medication alerting systems impede users, and ultimately their work system, and negatively impact patient safety. Therefore, the usability dimension may act as a hidden explanatory variable that could explain, at least partly, the (absence of) intended outcomes of new technology.
Usability Flaws in Medication Alerting Systems: Impact on Usage and Work System
Ammenwerth, E.; Roehrer, E.; Pelayo, S.; Vasseur, F.; Beuscart-Zéphir, M.-C.
2015-01-01
Summary Objectives Previous research has shown that medication alerting systems face usability issues. There has been no previous attempt to systematically explore the consequences of usability flaws in such systems on users (i.e. usage problems) and work systems (i.e. negative outcomes). This paper aims at exploring and synthesizing the consequences of usability flaws in terms of usage problems and negative outcomes on the work system. Methods A secondary analysis of 26 papers included in a prior systematic review of the usability flaws in medication alerting was performed. Usage problems and negative outcomes were extracted and sorted. Links between usability flaws, usage problems, and negative outcomes were also analyzed. Results Poor usability generates a large variety of consequences. It impacts the user from a cognitive, behavioral, emotional, and attitudinal perspective. Ultimately, usability flaws have negative consequences on the workflow, the effectiveness of the technology, the medication management process, and, more importantly, patient safety. Only few complete pathways leading from usability flaws to negative outcomes were identified. Conclusion Usability flaws in medication alerting systems impede users, and ultimately their work system, and negatively impact patient safety. Therefore, the usability dimension may act as a hidden explanatory variable that could explain, at least partly, the (absence of) intended outcomes of new technology. PMID:26123906
Klumpner, Thomas T; Kountanis, Joanna A; Langen, Elizabeth S; Smith, Roger D; Tremper, Kevin K
2018-06-26
Maternal early warning systems reduce maternal morbidity. We developed an electronic maternal surveillance system capable of visually summarizing the labor and delivery census and identifying changes in clinical status. Automatic page alerts to clinical providers, using an algorithm developed at our institution, were incorporated in an effort to improve early detection of maternal morbidity. We report the frequency of pages generated by the system. To our knowledge, this is the first time such a system has been used in peripartum care. Alert criteria were developed after review of maternal early warning systems, including the Maternal Early Warning Criteria (MEWC). Careful consideration was given to the frequency of pages generated by the surveillance system. MEWC notification criteria were liberalized and a paging algorithm was created that triggered paging alerts to first responders (nurses) and then managing services due to the assumption that paging all clinicians for each vital sign triggering MEWC would generate an inordinate number of pages. For preliminary analysis, to determine the effect of our automated paging algorithm on alerting frequency, the paging frequency of this system was compared to the frequency of vital signs meeting the Maternal Early Warning Criteria (MEWC). This retrospective analysis was limited to a sample of 34 patient rooms uniquely capable of storing every vital sign reported by the bedside monitor. Over a 91-day period, from April 1 to July 1, 2017, surveillance was conducted from 64 monitored beds, and the obstetrics service received one automated page every 2.3 h. The most common triggers for alerts were for hypertension and tachycardia. For the subset of 34 patient rooms uniquely capable of real-time recording, one vital sign met the MEWC every 9.6 to 10.3 min. Anecdotally, the system was well-received. This novel electronic maternal surveillance system is designed to reduce cognitive bias and improve timely clinical recognition of maternal deterioration. The automated paging algorithm developed for this software dramatically reduces paging frequency compared to paging for isolated vital sign abnormalities alone. Long-term, prospective studies will be required to determine its impact on patient outcomes.
47 CFR 11.52 - EAS code and Attention Signal Monitoring requirements.
Code of Federal Regulations, 2012 CFR
2012-10-01
... technologies, such as instant messaging and email) the distribution of Common Alert Protocol (CAP)-formatted... Integrated Public Alert and Warning System (IPAWS) to enable (whether through “pull” interface technologies...
47 CFR 11.52 - EAS code and Attention Signal Monitoring requirements.
Code of Federal Regulations, 2013 CFR
2013-10-01
... technologies, such as instant messaging and email) the distribution of Common Alert Protocol (CAP)-formatted... Integrated Public Alert and Warning System (IPAWS) to enable (whether through “pull” interface technologies...
47 CFR 11.52 - EAS code and Attention Signal Monitoring requirements.
Code of Federal Regulations, 2014 CFR
2014-10-01
... technologies, such as instant messaging and email) the distribution of Common Alert Protocol (CAP)-formatted... Integrated Public Alert and Warning System (IPAWS) to enable (whether through “pull” interface technologies...
Impact of Homeland Security Alert level on calls to a law enforcement peer support hotline.
Omer, Saad B; Barnett, Daniel J; Castellano, Cherie; Wierzba, Rachel K; Hiremath, Girish S; Balicer, Ran D; Everly, George S
2007-01-01
The Homeland Security Advisory System (HSAS) was established by the Department of Homeland Security to communicate the risk of a terrorist event. In order to explore the potential psychological impacts of HSAS we analyzed the effects of terror alerts on the law enforcement community. We used data from the New Jersey Cop 2 Cop crisis intervention hotline. Incidence Rate Ratios--interpreted as average relative increases in the daily number of calls to the Cop 2 Cop hotline during an increased alert period--were computed from Poisson models. The hotline received a total of 4,145 initial calls during the study period. The mean daily number of calls was higher during alert level elevation compared to prior 7 days (7.68 vs. 8.00). In the Poisson regression analysis, the Incidence Rate Ratios of number of calls received during elevated alert levels compared to the reference period of seven days preceding each change in alert were close to 1, with confidence intervals crossing 1 (i.e. not statistically significant) for all lag periods evaluated. This investigation, in the context of New Jersey law enforcement personnel, does not support the concern that elevating the alert status places undue stress upon alert recipients.
Wireless alerting system using vibration for vehicles dashboard
NASA Astrophysics Data System (ADS)
Raj, Sweta; Rai, Shweta; Magaramagara, Wilbert; Sivacoumar, R.
2017-11-01
This paper aims at improving the engine life of any vehicle through a continuous measurement and monitoring of vital engine operational parameters and providing an effective alerting to drivers for any abnormality. Vehicles currently are using audio and visible alerting signals through alarms and light as a warning to the driver but these are not effective in noisy environments and during daylight. Through the use of the sense of feeling a driver can be alerted effectively. The need to no other vehicle parameter needs to be aided through the mobile display (phone).Thus a system is designed and implements to measure engine temperature, RPM, Oil level and Coolant level using appropriate sensors and a wireless communication (Bluetooth) is established to actuate a portable vibration control device and to read the different vehicle sensor readings through an android application for display and diagnosis.
Automated health alerts from Kinect-based in-home gait measurements.
Stone, Erik E; Skubic, Marjorie; Back, Jessica
2014-01-01
A method for automatically generating alerts to clinicians in response to changes in in-home gait parameters is investigated. Kinect-based gait measurement systems were installed in apartments in a senior living facility. The systems continuously monitored the walking speed, stride time, and stride length of apartment residents. A framework for modeling uncertainty in the residents' gait parameter estimates, which is critical for robust change detection, is developed; along with an algorithm for detecting changes that may be clinically relevant. Three retrospective case studies, of individuals who had their gait monitored for periods ranging from 12 to 29 months, are presented to illustrate use of the alert method. Evidence suggests that clinicians could be alerted to health changes at an early stage, while they are still small and interventions may be most successful. Additional potential uses are also discussed.
Legutko, Jacek; Zasada, Wojciech; Kałuża, Grzegorz L.; Heba, Grzegorz; Rzeszutko, Lukasz; Jakala, Jacek; Dragan, Jacek; Klecha, Artur; Giszterowicz, Dawid; Dobrowolski, Wojciech; Partyka, Łukasz; Jayaraman, Swaminathan; Dudek, Dariusz
2013-01-01
Aims Evaluation of safety and efficacy of ProNOVA XR, a new generation of polymer-free sirolimus eluting stents (SES), utilizing a pharmaceutical excipient for timed release of sirolimus from the XR platform. Methods and results Safety and efficacy of ProNOVA XR coronary stent system was examined in EURONOVA prospective, single arm, multi-center registry of 50 patients with de novo native coronary lesions up to 28 mm in length in arteries between 2.25 and 4 mm. At 6-month, in-stent late lumen loss by QCA was 0.45 ± 0.41 mm and in-stent neointimal volume obstruction in the IVUS sub-study was 14 ± 11%. One-year clinical follow-up revealed a favorable safety profile, with 2% of in-hospital MACE and 6.4% of MACE from hospital discharge up to 12 months (including 1 cardiac death >30 days after stent implantation and 2 TLRs). According to the ARC definition, there was no definite or probable stent thrombosis and 1 possible stent thrombosis (2%) up to 12 months of clinical follow-up. Conclusions In this preliminary evaluation, ProNOVA XR polymer-free sirolimus eluting stent system appeared safe with an early promise of adequate effectiveness in the treatment of de novo coronary lesions in up to 12 months of clinical, angiographic and IVUS follow-up. PMID:23992999
Bode, Bruce; Gross, Kenneth; Rikalo, Nancy; Schwartz, Sherwyn; Wahl, Timothy; Page, Casey; Gross, Todd; Mastrototaro, John
2004-04-01
The purposes of this study were to demonstrate the accuracy and effectiveness of the Guardian Continuous Monitoring System (Medtronic MiniMed, Northridge, California) and to demonstrate that the application of real-time alarms to continuous monitoring alerts users to hypo and hyperglycemia and reduces excursions in people with diabetes. A total of 71 subjects with type 1 diabetes, mean hemoglobin A1c of 7.6 +/- 1.1%, age 44.0 +/- 11.4 years, and duration of diabetes 23.6 +/- 10.6 years were enrolled in this two-period, randomized, multicenter study. Subjects were randomized into either an Alert group or a Control group. The accuracy of the Guardian was evaluated by treating the study data as a single-sample correlational design. Effectiveness of the Guardian alerts was evaluated by comparing the Alert group with the Control group. The mean (median) absolute relative error between home blood glucose meter readings and sensor values was 21.3% (17.3%), and the Guardian, on average, read 12.8 mg/dL below the concurrent home blood glucose meter readings. The hypoglycemia alert was able to distinguished glucose values < or =70 mg/dL with 67% sensitivity, 90% specificity, and 47% false alerts. The hyperglycemia alert showed a similar ability to detect sensor values > or =250 mg/dL with 63% sensitivity, 97% specificity, and 19% false alerts. The Alert group demonstrated a median decrease in the duration of hypoglycemic excursions (-27.8 min) that was significantly greater than the median decrease in the duration of hypoglycemic excursions in the Control group (-4.5 min) (P = 0.03). A marginally significant increase in the frequency of hyperglycemic excursions (P = 0.07) between Period 1 and Period 2 was accompanied by a decrease of 9.6 min in the duration of hyperglycemic excursions in the Alert group. Glucose measurements differ between blood samples taken from the finger and interstitial fluid, especially when levels are changing rapidly; however, these results demonstrate that the Guardian is reasonably accurate while performing continuous glucose monitoring. The subjects' responses to hypoglycemia alerts resulted in a significant reduction in the duration of hypoglycemic excursions; however, overtreating hypoglycemia may have resulted in a marginally significant increase in the frequency of hyperglycemic excursions.